Sample records for abdominal ct exams

  1. DICOM structured report to track patient's radiation dose to organs from abdominal CT exam

    NASA Astrophysics Data System (ADS)

    Morioka, Craig; Turner, Adam; McNitt-Gray, Michael; Zankl, Maria; Meng, Frank; El-Saden, Suzie

    2011-03-01

    The dramatic increase of diagnostic imaging capabilities over the past decade has contributed to increased radiation exposure to patient populations. Several factors have contributed to the increase in imaging procedures: wider availability of imaging modalities, increase in technical capabilities, rise in demand by patients and clinicians, favorable reimbursement, and lack of guidelines to control utilization. The primary focus of this research is to provide in depth information about radiation doses that patients receive as a result of CT exams, with the initial investigation involving abdominal CT exams. Current dose measurement methods (i.e. CTDIvol Computed Tomography Dose Index) do not provide direct information about a patient's organ dose. We have developed a method to determine CTDIvol normalized organ doses using a set of organ specific exponential regression equations. These exponential equations along with measured CTDIvol are used to calculate organ dose estimates from abdominal CT scans for eight different patient models. For each patient, organ dose and CTDIvol were estimated for an abdominal CT scan. We then modified the DICOM Radiation Dose Structured Report (RDSR) to store the pertinent patient information on radiation dose to their abdominal organs.

  2. Abdominal CT scan

    MedlinePlus

    Computed tomography scan - abdomen; CT scan - abdomen; CT abdomen and pelvis ... An abdominal CT scan makes detailed pictures of the structures inside your belly very quickly. This test may be used to look ...

  3. Blunt abdominal trauma in children.

    PubMed

    Schonfeld, Deborah; Lee, Lois K

    2012-06-01

    This review will examine the current evidence regarding pediatric blunt abdominal trauma and the physical exam findings, laboratory values, and radiographic imaging associated with the diagnosis of intra-abdominal injuries (IAI), as well as review the current literature on pediatric hollow viscus injuries and emergency department disposition after diagnosis. The importance of the seat belt sign on physical examination and screening laboratory data remains controversial, although screening hepatic enzymes are recommended in the evaluation of nonaccidental trauma to identify occult abdominal organ injuries. Focused Assessment with Sonography for Trauma (FAST) has modest sensitivity for hemoperitoneum and IAI in the pediatric trauma patient. Patients with concern for undiagnosed IAI, including bowel injury, may be considered for hospital admission and serial abdominal exams without an increased risk of complications, if an exploratory laparotomy is not performed emergently. Although the FAST exam is not recommended as the sole screening tool to rule out IAI in hemodynamically stable trauma patients, it may be used in conjunction with the physical exam and laboratory findings to identify children at risk for IAI. Children with a normal physical exam and normal abdominal CT may not require routine hospitalization after blunt abdominal trauma.

  4. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nawfel, RD; Young, G

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dosemore » metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.« less

  5. Progress in Fully Automated Abdominal CT Interpretation

    PubMed Central

    Summers, Ronald M.

    2016-01-01

    OBJECTIVE Automated analysis of abdominal CT has advanced markedly over just the last few years. Fully automated assessment of organs, lymph nodes, adipose tissue, muscle, bowel, spine, and tumors are some examples where tremendous progress has been made. Computer-aided detection of lesions has also improved dramatically. CONCLUSION This article reviews the progress and provides insights into what is in store in the near future for automated analysis for abdominal CT, ultimately leading to fully automated interpretation. PMID:27101207

  6. Scrub typhus associated hepatic dysfunction and abdominal CT findings

    PubMed Central

    Park, Man Je; Lee, Hyoun Soo; Shim, Sang Goon; Kim, So Hee

    2015-01-01

    Objective: This retrospective study investigated abnormal hepatic dysfunction and abdominal computed tomography (CT) findings in scrub typhus. Methods: Three hundred forty nine adult patients were diagnosed with scrub typhus. Ninety four underwent abdominal CT. The CT images were reviewed by the attending radiologist. Patient data of history, symptoms, signs, and results of laboratory tests were collected from the electronic medical records. Results: In 349 patients with scrub typhus, elevation of aspartate aminotransferase (78.5%) and alanine aminotransferase (63.0%) were dominant compared to alkaline phosphatase (27.2%) and total bilirubin (16.1%). Abdominal CT findings of 94 patients were, in descending order of frequency, enlarged lymph node (53.2%), inhomogeneous enhancement of liver (47.9%), splenomegaly (46.8%), ascites (28.7%), low attenuation of periportal areas (27.7%), gallbladder wall thickening (17.0%), and splenic infarct (6.4%). Also, the level of aspartate aminotransferase tended to be elevated according to the number of CT findings (P= 0.028) Conclusions: We found that abdominal CT manifestations of scrub typhus with elevated aminotransferases were varied and not specific. However, knowledge of these findings may evoke the recognition of scrub typhus by clinicians in endemic areas. PMID:26101478

  7. Relevant incidental findings at abdominal multi-detector contrast-enhanced computed tomography: A collateral screening?

    PubMed Central

    Sconfienza, Luca Maria; Mauri, Giovanni; Muzzupappa, Claudia; Poloni, Alessandro; Bandirali, Michele; Esseridou, Anastassia; Tritella, Stefania; Secchi, Francesco; Di Leo, Giovanni; Sardanelli, Francesco

    2015-01-01

    AIM: To investigate the prevalence of relevant incidental findings (RIFs) detected during routine abdominal contrast-enhanced computed tomography (CeCT). METHODS: We retrospectively evaluated the reports of a consecutive series of abdominal CeCT studies performed between January and May 2013. For each report, patients’ age and sex, admission as inpatient or outpatient, clinical suspicion as indicated by the requesting physician, availability of a previous abdominal examination, and name of the reporting radiologist were recorded. Based on the clinical suspicion, the presence and features of any RIFs (if needing additional workup) was noted. RESULTS: One thousand forty abdominal CeCT were performed in 949 patients (528 males, mean age 66 ± 14 years). No significant difference was found between inpatients and outpatients age and sex distribution (P > 0.472). RIFs were found in 195/1040 (18.8%) CeCT [inpatients = 108/470 (23.0%); outpatients = 87/570 (15.2%); P = 0.002]. RIFs were found in 30/440 (6.8%) CeCT with a previous exam and in 165/600 (27.5%) without a previous exam (P < 0.001). Radiologists’ distribution between inpatients or outpatients was significantly different (P < 0.001). RIFs prevalence increased with aging, except for a peak in 40-49 year group. Most involved organs were kidneys, gallbladder, and lungs. CONCLUSION: A RIF is detected in 1/5 patients undergoing abdominal CeCT. Risk of overdiagnosis should be taken into account. PMID:26516432

  8. Computed tomographic evaluation of abdominal fat in minipigs.

    PubMed

    Chang, Jinhwa; Jung, Joohyun; Lee, Hyeyeon; Chang, Dongwoo; Yoon, Junghee; Choi, Mincheol

    2011-03-01

    Computed tomography (CT) exams were conducted to determine the distribution of abdominal fat identified based on the CT number measured in Hounsfield Units (HU) and to measure the volume of the abdominal visceral and subcutaneous fat in minipigs. The relationship between the CT-based fat volumes of several vertebral levels and the entire abdomen and anthropometric data including the sagittal abdominal diameter and waist circumference were evaluated. Moreover, the total fat volumes at the T11, T13, L3, and L5 levels were compared with the total fat volume of the entire abdomen to define the landmark of abdominal fat distribution. Using a single-detector CT, six 6-month-old male minipigs were scanned under general anesthesia. Three radiologists then assessed the HU value of visceral and subcutaneous abdominal fat by drawing the region of interest manually at the T11, T13, L1, L3, and L5 levels. The CT number and abdominal fat determined in this way by the three radiologists was found to be correlated (intra-class coefficient = 0.9). The overall HU ranges for the visceral and subcutaneous fat depots were -147.47 to -83.46 and -131.62 to -90.97, respectively. The total fat volume of the entire abdomen was highly correlated with the volume of abdominal fat at the T13 level (r = 0.97, p < 0.0001). These findings demonstrate that the volume of abdominal adipose tissue measured at the T13 level using CT is a strong and reliable predictor of total abdominal adipose volume.

  9. Fully automated adipose tissue measurement on abdominal CT

    NASA Astrophysics Data System (ADS)

    Yao, Jianhua; Sussman, Daniel L.; Summers, Ronald M.

    2011-03-01

    Obesity has become widespread in America and has been associated as a risk factor for many illnesses. Adipose tissue (AT) content, especially visceral AT (VAT), is an important indicator for risks of many disorders, including heart disease and diabetes. Measuring adipose tissue (AT) with traditional means is often unreliable and inaccurate. CT provides a means to measure AT accurately and consistently. We present a fully automated method to segment and measure abdominal AT in CT. Our method integrates image preprocessing which attempts to correct for image artifacts and inhomogeneities. We use fuzzy cmeans to cluster AT regions and active contour models to separate subcutaneous and visceral AT. We tested our method on 50 abdominal CT scans and evaluated the correlations between several measurements.

  10. CT of abdominal tuberculosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Epstein, B.M.; Mann, J.H.

    1982-11-01

    Intraabdominal tuberculosis (TB) presents with a wide variety of clinical and radiologic features. Besides the reported computed tomographic (CT) finding of high-density ascites in tuberculous peritonitis, this report describes additional CT features highly suggestive of abdominal tuberculosis in eight cases: (1) irregular soft-tissue densities in the omental area; (2) low-density masses surrounded by thick solid rims; (3) a disorganized appearance of soft-tissue densities, fluid, and bowel loops forming a poorly defined mass; (4) low-density lymph nodes with a multilocular appearance after intravenous contrast administration; and (5) possibly high-density ascites. The differential diagnosis of these features include lymphoma, various forms ofmore » peritonitis, peritoneal carcinomatosis, and peritoneal mesothelioma. It is important that the CT features of intraabdominal tuberculosis be recognized in order that laparotomy be avoided and less invasive procedures (e.g., laparoscopy, biopsy, or a trial of antituberculous therapy) be instituted.« less

  11. Computed Tomography (CT) Imaging of Injuries from Blunt Abdominal Trauma: A Pictorial Essay.

    PubMed

    Hassan, Radhiana; Abd Aziz, Azian

    2010-04-01

    Blunt abdominal trauma can cause multiple internal injuries. However, these injuries are often difficult to accurately evaluate, particularly in the presence of more obvious external injuries. Computed tomography (CT) imaging is currently used to assess clinically stable patients with blunt abdominal trauma. CT can provide a rapid and accurate appraisal of the abdominal viscera, retroperitoneum and abdominal wall, as well as a limited assessment of the lower thoracic region and bony pelvis. This paper presents examples of various injuries in trauma patients depicted in abdominal CT images. We hope these images provide a resource for radiologists, surgeons and medical officers, as well as a learning tool for medical students.

  12. Automated anatomical labeling method for abdominal arteries extracted from 3D abdominal CT images

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Hoang, Bui Huy; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Mori, Kensaku

    2012-02-01

    This paper presents an automated anatomical labeling method of abdominal arteries. In abdominal surgery, understanding of blood vessel structure concerning with a target organ is very important. Branching pattern of blood vessels differs among individuals. It is required to develop a system that can assist understanding of a blood vessel structure and anatomical names of blood vessels of a patient. Previous anatomical labbeling methods for abdominal arteries deal with either of the upper or lower abdominal arteries. In this paper, we present an automated anatomical labeling method of both of the upper and lower abdominal arteries extracted from CT images. We obtain a tree structure of artery regions and calculate feature values for each branch. These feature values include the diameter, curvature, direction, and running vectors of a branch. Target arteries of this method are grouped based on branching conditions. The following processes are separately applied for each group. We compute candidate artery names by using classifiers that are trained to output artery names. A correction process of the candidate anatomical names based on the rule of majority is applied to determine final names. We applied the proposed method to 23 cases of 3D abdominal CT images. Experimental results showed that the proposed method is able to perform nomenclature of entire major abdominal arteries. The recall and the precision rates of labeling are 79.01% and 80.41%, respectively.

  13. Developing patient-specific dose protocols for a CT scanner and exam using diagnostic reference levels.

    PubMed

    Strauss, Keith J

    2014-10-01

    The management of image quality and radiation dose during pediatric CT scanning is dependent on how well one manages the radiographic techniques as a function of the type of exam, type of CT scanner, and patient size. The CT scanner's display of expected CT dose index volume (CTDIvol) after the projection scan provides the operator with a powerful tool prior to the patient scan to identify and manage appropriate CT techniques, provided the department has established appropriate diagnostic reference levels (DRLs). This paper provides a step-by-step process that allows the development of DRLs as a function of type of exam, of actual patient size and of the individual radiation output of each CT scanner in a department. Abdomen, pelvis, thorax and head scans are addressed. Patient sizes from newborns to large adults are discussed. The method addresses every CT scanner regardless of vendor, model or vintage. We cover adjustments to techniques to manage the impact of iterative reconstruction and provide a method to handle all available voltages other than 120 kV. This level of management of CT techniques is necessary to properly monitor radiation dose and image quality during pediatric CT scans.

  14. Estimating radiation dose to organs of patients undergoing conventional and novel multidetector CT exams using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Angel, Erin

    Advances in Computed Tomography (CT) technology have led to an increase in the modality's diagnostic capabilities and therefore its utilization, which has in turn led to an increase in radiation exposure to the patient population. As a result, CT imaging currently constitutes approximately half of the collective exposure to ionizing radiation from medical procedures. In order to understand the radiation risk, it is necessary to estimate the radiation doses absorbed by patients undergoing CT imaging. The most widely accepted risk models are based on radiosensitive organ dose as opposed to whole body dose. In this research, radiosensitive organ dose was estimated using Monte Carlo based simulations incorporating detailed multidetector CT (MDCT) scanner models, specific scan protocols, and using patient models based on accurate patient anatomy and representing a range of patient sizes. Organ dose estimates were estimated for clinical MDCT exam protocols which pose a specific concern for radiosensitive organs or regions. These dose estimates include estimation of fetal dose for pregnant patients undergoing abdomen pelvis CT exams or undergoing exams to diagnose pulmonary embolism and venous thromboembolism. Breast and lung dose were estimated for patients undergoing coronary CTA imaging, conventional fixed tube current chest CT, and conventional tube current modulated (TCM) chest CT exams. The correlation of organ dose with patient size was quantified for pregnant patients undergoing abdomen/pelvis exams and for all breast and lung dose estimates presented. Novel dose reduction techniques were developed that incorporate organ location and are specifically designed to reduce close to radiosensitive organs during CT acquisition. A generalizable model was created for simulating conventional and novel attenuation-based TCM algorithms which can be used in simulations estimating organ dose for any patient model. The generalizable model is a significant contribution of this

  15. Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostani, Maryam, E-mail: mbostani@mednet.ucla.edu; McMillan, Kyle; Lu, Peiyun

    2015-02-15

    Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans frommore » clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for

  16. Systemic mastocytosis: CT and US features of abdominal manifestations.

    PubMed

    Avila, N A; Ling, A; Worobec, A S; Mican, J M; Metcalfe, D D

    1997-02-01

    To study the imaging findings in patients with systemic mastocytosis and to correlate the findings with the severity of disease on the basis of an established classification system. Pathologic findings, when available, were correlated with imaging findings. Computed tomographic (CT) and ultrasound (US) scans and corresponding pathologic findings, when available, were retrospectively reviewed in 27 patients with systemic mastocytosis. Only five (19%) of the patients in our series had normal abdominal CT and/or US examination results. Common abdominal imaging findings associated with systemic mastocytosis were hepatosplenomegaly, retroperitoneal adenopathy, periportal adenopathy, mesenteric adenopathy, thickening of the omentum and the mesentery, and ascites. Less common findings included hepatofugal portal venous flow, Budd-Chiari syndrome, cavernous transformation of the portal vein, ovarian mass, and complications such as chloroma. The findings were more common in patients with category II and those with category III disease. Abdominal findings at CT and US are common in patients with systemic mastocytosis. Although the findings in patients with systemic mastocytosis are not specific to the disease, they are useful in directing further studies for diagnostic confirmation and in estimating the extent of systemic involvement.

  17. Scanning and War: Utility of FAST and CT in the Assessment of Battlefield Abdominal Trauma.

    PubMed

    Smith, Iain M; Naumann, David N; Marsden, Max E R; Ballard, Mark; Bowley, Douglas M

    2015-08-01

    To determine utilization and accuracy of focused assessment with sonography for trauma (FAST) and computed tomography (CT) in a mature military trauma system to inform service provision for future conflicts. FAST and CT scans undertaken by attending radiologists contribute to surgical decision making for battlefield casualties at the Joint Force, Role 3 Medical Treatment Facility at Camp Bastion (R3), Afghanistan. Registry data for abdominally injured casualties treated at R3 from July to November 2012 were matched to radiological and surgical records to determine diagnostic accuracy for FAST and CT and their influence on casualty management. A total of 468 casualties met inclusion criteria, of whom 85.0% underwent FAST and 86.1% abdominal CT; 159 (34.0%) had abdominal injuries. For detection of intra-abdominal injury, FAST sensitivity (Sn) was 0.56, specificity (Sp) 0.98, positive predictive value (PPV) 0.87, negative predictive value (NPV) 0.90, and accuracy (Acc) 0.89. For CT, Sn was 0.99, Sp 0.99, PPV 0.96, NPV 1.00, and Acc 0.99. Forty-six solid organ injuries were identified in 38 patients by CT; 17 were managed nonoperatively. A further 61 patients avoided laparotomy after CT confirmed extra-abdominal wounds only. The negative laparotomy rate was 3.9%. FAST and CT contribute to triage, guide surgical management, and reduce nontherapeutic laparotomy. When imaging is available, these data challenge current doctrine about inadvisability of nonoperative management of abdominal injury after combat trauma.

  18. Unsupervised quantification of abdominal fat from CT images using Greedy Snakes

    NASA Astrophysics Data System (ADS)

    Agarwal, Chirag; Dallal, Ahmed H.; Arbabshirani, Mohammad R.; Patel, Aalpen; Moore, Gregory

    2017-02-01

    Adipose tissue has been associated with adverse consequences of obesity. Total adipose tissue (TAT) is divided into subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT). Intra-abdominal fat (VAT), located inside the abdominal cavity, is a major factor for the classic obesity related pathologies. Since direct measurement of visceral and subcutaneous fat is not trivial, substitute metrics like waist circumference (WC) and body mass index (BMI) are used in clinical settings to quantify obesity. Abdominal fat can be assessed effectively using CT or MRI, but manual fat segmentation is rather subjective and time-consuming. Hence, an automatic and accurate quantification tool for abdominal fat is needed. The goal of this study is to extract TAT, VAT and SAT fat from abdominal CT in a fully automated unsupervised fashion using energy minimization techniques. We applied a four step framework consisting of 1) initial body contour estimation, 2) approximation of the body contour, 3) estimation of inner abdominal contour using Greedy Snakes algorithm, and 4) voting, to segment the subcutaneous and visceral fat. We validated our algorithm on 952 clinical abdominal CT images (from 476 patients with a very wide BMI range) collected from various radiology departments of Geisinger Health System. To our knowledge, this is the first study of its kind on such a large and diverse clinical dataset. Our algorithm obtained a 3.4% error for VAT segmentation compared to manual segmentation. These personalized and accurate measurements of fat can complement traditional population health driven obesity metrics such as BMI and WC.

  19. Integrated circuit detector technology in abdominal CT: added value in obese patients.

    PubMed

    Morsbach, Fabian; Bickelhaupt, Sebastian; Rätzer, Susan; Schmidt, Bernhard; Alkadhi, Hatem

    2014-02-01

    The purpose of this article was to assess the effect of an integrated circuit (IC) detector for abdominal CT on image quality. In the first study part, an abdominal phantom was scanned with various extension rings using a CT scanner equipped with a conventional discrete circuit (DC) detector and on the same scanner with an IC detector (120 kVp, 150 effective mAs, and 75 effective mAs). In the second study part, 20 patients were included who underwent abdominal CT both with the IC detector and previously at similar protocol parameters (120 kVp tube current-time product and 150 reference mAs using automated tube current modulation) with the DC detector. Images were reconstructed with filtered back projection. Image quality in the phantom was higher for images acquired with the IC compared with the DC detector. There was a gradually increasing noise reduction with increasing phantom sizes, with the highest (37% in the largest phantom) at 75 effective mAs (p < 0.001). In patients, noise was overall significantly (p = 0.025) reduced by 6.4% using the IC detector. Similar to the phantom, there was a gradual increase in noise reduction to 7.9% in patients with a body mass index of 25 kg/m(2) or lower (p = 0.008). Significant correlation was found in patients between noise and abdominal diameter in DC detector images (r = 0.604, p = 0.005), whereas no such correlation was found for the IC detector (r = 0.427, p = 0.060). Use of an IC detector in abdominal CT improves image quality and reduces image noise, particularly in overweight and obese patients. This noise reduction has the potential for dose reduction in abdominal CT.

  20. Are facilities following best practices of pediatric abdominal CT scans?

    PubMed

    Nosek, Amy E; Hartin, Charles W; Bass, Kathryn D; Glick, Philip L; Caty, Michael G; Dayton, Merril T; Ozgediz, Doruk E

    2013-05-01

    Established guidelines for pediatric abdominal CT scans include reduced radiation dosage to minimize cancer risk and the use of intravenous (IV) contrast to obtain the highest-quality diagnostic images. We wish to determine if these practices are being used at nonpediatric facilities that transfer children to a pediatric facility. Children transferred to a tertiary pediatric facility over a 16-mo period with abdominal CT scans performed for evaluation of possible appendicitis were retrospectively reviewed for demographics, diagnosis, radiation dosage, CT contrast use, and scan quality. If CT scans were repeated, the radiation dosage between facilities was compared using Student t-test. Ninety-one consecutive children transferred from 29 different facilities had retrievable CT scan images and clinical information. Half of CT scans from transferring institutions used IV contrast. Due to poor quality or inconclusive CT scans, 19 patients required a change in management. Children received significantly less radiation at our institution compared to the referring adult facility for the same body area scanned on the same child (9.7 mSv versus 19.9 mSv, P = 0.0079). Pediatric facilities may be using less radiation per CT scan due to a heightened awareness of radiation risks and specific pediatric CT scanning protocols. The benefits of IV contrast for the diagnostic yield of pediatric CT scans should be considered to obtain the best possible image and to prevent additional imaging. Every facility performing pediatric CT scans should minimize radiation exposure, and pediatric facilities should provide feedback and education to other facilities scanning children. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry.

    PubMed

    Manios, G E; Mazonakis, M; Voulgaris, C; Karantanas, A; Damilakis, J

    2016-03-01

    To deploy and evaluate a stereological point-counting technique on abdominal CT for the estimation of visceral (VAF) and subcutaneous abdominal fat (SAF) volumes. Stereological volume estimations based on point counting and systematic sampling were performed on images from 14 consecutive patients who had undergone abdominal CT. For the optimization of the method, five sampling intensities in combination with 100 and 200 points were tested. The optimum stereological measurements were compared with VAF and SAF volumes derived by the standard technique of manual planimetry on the same scans. Optimization analysis showed that the selection of 200 points along with the sampling intensity 1/8 provided efficient volume estimations in less than 4 min for VAF and SAF together. The optimized stereology showed strong correlation with planimetry (VAF: r = 0.98; SAF: r = 0.98). No statistical differences were found between the two methods (VAF: P = 0.81; SAF: P = 0.83). The 95% limits of agreement were also acceptable (VAF: -16.5%, 16.1%; SAF: -10.8%, 10.7%) and the repeatability of stereology was good (VAF: CV = 4.5%, SAF: CV = 3.2%). Stereology may be successfully applied to CT images for the efficient estimation of abdominal fat volume and may constitute a good alternative to the conventional planimetric technique. Abdominal obesity is associated with increased risk of disease and mortality. Stereology may quantify visceral and subcutaneous abdominal fat accurately and consistently. The application of stereology to estimating abdominal volume fat reduces processing time. Stereology is an efficient alternative method for estimating abdominal fat volume.

  2. SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, X; Yang, K; Liu, B

    Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length wasmore » used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.« less

  3. Does Pelvic Exam in the Emergency Department Add Useful Information?

    PubMed Central

    Brown, Jeremy; Fleming, Rita; Aristzabel, Jamie; Gishta, Rocksolana

    2011-01-01

    Objective: Physicians are taught that the pelvic exam is a key part of the evaluation of a woman presenting with abdominal pain or vaginal bleeding. However, the exam is time consuming and invasive, and its use in the emergency department (ED) has not been prospectively evaluated. We evaluated how often the findings of the pelvic exam changed management in a cohort of consecutive female patients presenting with acute abdominal pain or vaginal bleeding. Methods: We enrolled women who required a pelvic exam together with the providers caring for them in an academic ED from September 2004 to August 2005. We collected the results of the general history and physical exam. The provider was asked to predict the findings of the pelvic exam, and these were compared with the actual findings of the exam. Results: One hundred eighty-three patients were prospectively entered into the study. When compared with predicted findings, the pelvic exam was as expected in 131 patients (72%). In a further 40 patients (22%), the findings of the pelvic exam were not as predicted, but resulted in no change in the clinical plan. In 12 cases (6%) the exam revealed a finding that was both unexpected and changed the clinical plan. Only one of these patients was admitted. Of the 24 patients who were admitted, four had a pelvic exam that revealed unexpected results, but only one of these cases caused the physician to change the care planned for the patient. Conclusion: In 94% of women with acute abdominal pain or vaginal bleeding, the results of the pelvic exam were either predictable or had no effect on the clinical plan. This suggests that there may be a subset of women with abdominal pain or vaginal bleeding in whom a pelvic exam may safely be deferred. PMID:21691528

  4. Image mottle in abdominal CT.

    PubMed

    Ende, J F; Huda, W; Ros, P R; Litwiller, A L

    1999-04-01

    To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mottle in CT as a function of x-ray tube potential and mAs. CT images from 39 consecutive patients with noncontrast liver scans and 49 patients with iodine contrast scans were analyzed retrospectively. Measurements were made of the mean liver parenchyma Hounsfield unit value and the corresponding image mottle. For a given water phantom and x-ray tube potential, image mottle was proportional to the mAs-0.5. Increasing the phantom diameter from 16 cm (pediatric) to 32 cm increased the mottle by a factor of 2.4, and increasing the x-ray tube potential from 80 kVp to 140 kVp reduced the mottle by a factor of 2.5. All patients were scanned at 120 kVp, with no correlation between patient size and the x-ray tube mAs. The mean mottle level was 7.8 +/- 2.2 and 10.0 +/- 2.5 for the noncontrast and contrast studies, respectively. An increase in patient diameter of 3 cm would require approximately 65% more mAs to maintain the same level of image mottle. The mottle in abdominal CT images may be controlled by adjusting radiographic technique factors, which should be adjusted to take into account the size of the patient undergoing the examination.

  5. Relationship between sudden natural death and abdominal fat evaluated on postmortem CT scans.

    PubMed

    Kaichi, Y; Sakane, H; Higashibori, H; Honda, Y; Tatsugami, F; Baba, Y; Iida, M; Awai, K

    2017-06-01

    This study examined the association between sudden natural death and abdominal fat using postmortem computed tomography (CT) scans. Postmortem CT images at the umbilical level of 241 subjects were used to measure abdominal areas of subcutaneous- and visceral fat, the rate of visceral fat and the waist circumference. Of the study subjects, 174 died of sudden natural death (130 men and 44 women), and 67 died of different causes (46 men and 21 women). All were between 40 and 75 years of age. Logistic regression analysis was performed to identify independent abdominal parameters associated with sudden natural death. By univariate analysis, the areas of subcutaneous and visceral fat were significantly larger in sudden natural death than who died of different causes (subcutaneous fat, odds ratio [OR] = 1.004, 95% confidence interval [CI] = 1.000-1.007, p  = 0.03; visceral fat, OR = 1.008, 95% CI = 1.003-1.013, p  < 0.01). Multivariate analysis showed that the area of visceral fat was an independent factor associated with the risk of sudden natural death (OR = 1.008, 95% CI = 1.002-1.015, p  = 0.02). Postmortem CT revealed that sudden natural death was related to abdominal fat deposits.

  6. Low contrast detection in abdominal CT: comparing single-slice and multi-slice tasks

    NASA Astrophysics Data System (ADS)

    Ba, Alexandre; Racine, Damien; Viry, Anaïs.; Verdun, Francis R.; Schmidt, Sabine; Bochud, François O.

    2017-03-01

    Image quality assessment is crucial for the optimization of computed tomography (CT) protocols. Human and mathematical model observers are increasingly used for the detection of low contrast signal in abdominal CT, but are frequently limited to the use of a single image slice. Another limitation is that most of them only consider the detection of a signal embedded in a uniform background phantom. The purpose of this paper was to test if human observer performance is significantly different in CT images read in single or multiple slice modes and if these differences are the same for anatomical and uniform clinical images. We investigated detection performance and scrolling trends of human observers of a simulated liver lesion embedded in anatomical and uniform CT backgrounds. Results show that observers don't take significantly benefit of additional information provided in multi-slice reading mode. Regarding the background, performances are moderately higher for uniform than for anatomical images. Our results suggest that for low contrast detection in abdominal CT, the use of multi-slice model observers would probably only add a marginal benefit. On the other hand, the quality of a CT image is more accurately estimated with clinical anatomical backgrounds.

  7. TU-H-207A-09: An Automated Technique for Estimating Patient-Specific Regional Imparted Energy and Dose From TCM CT Exams Across 13 Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanders, J; Tian, X; Segars, P

    2016-06-15

    Purpose: To develop an automated technique for estimating patient-specific regional imparted energy and dose from tube current modulated (TCM) computed tomography (CT) exams across a diverse set of head and body protocols. Methods: A library of 58 adult computational anthropomorphic extended cardiac-torso (XCAT) phantoms were used to model a patient population. A validated Monte Carlo program was used to simulate TCM CT exams on the entire library of phantoms for three head and 10 body protocols. The net imparted energy to the phantoms, normalized by dose length product (DLP), and the net tissue mass in each of the scan regionsmore » were computed. A knowledgebase containing relationships between normalized imparted energy and scanned mass was established. An automated computer algorithm was written to estimate the scanned mass from actual clinical CT exams. The scanned mass estimate, DLP of the exam, and knowledgebase were used to estimate the imparted energy to the patient. The algorithm was tested on 20 chest and 20 abdominopelvic TCM CT exams. Results: The normalized imparted energy increased with increasing kV for all protocols. However, the normalized imparted energy was relatively unaffected by the strength of the TCM. The average imparted energy was 681 ± 376 mJ for abdominopelvic exams and 274 ± 141 mJ for chest exams. Overall, the method was successful in providing patientspecific estimates of imparted energy for 98% of the cases tested. Conclusion: Imparted energy normalized by DLP increased with increasing tube potential. However, the strength of the TCM did not have a significant effect on the net amount of energy deposited to tissue. The automated program can be implemented into the clinical workflow to provide estimates of regional imparted energy and dose across a diverse set of clinical protocols.« less

  8. Automated estimation of abdominal effective diameter for body size normalization of CT dose.

    PubMed

    Cheng, Phillip M

    2013-06-01

    Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.

  9. Evaluation of simethicone-coated cellulose as a negative oral contrast agent for abdominal CT.

    PubMed

    Sahani, Dushyant V; Jhaveri, Kartik S; D'souza, Roy V; Varghese, Jose C; Halpern, Elkan; Harisinghani, Mukesh G; Hahn, Peter F; Saini, Sanjay

    2003-05-01

    Because of the increased clinical use of computed tomography (CT) for imaging the abdominal vasculature and urinary tract, there is a need for negative contrast agents. The authors undertook this study to assess the suitability of simethicone-coated cellulose (SCC), which is approved for use as an oral contrast agent in sonography, for use as a negative oral contrast agent in abdominal CT. This prospective study involved 40 adult patients scheduled to undergo abdominal CT for the evaluation of hematuria. Prior to scanning, 20 subjects received 800 mL of SCC and 20 received 800 mL of water as an oral contrast agent. Imaging was performed with a multi-detector row helical scanner in two phases, according to the abdominal CT protocol used for hematuria evaluation at the authors' institution. The first, "early" phase began an average of 15 minutes after the ingestion of contrast material; the second, "late" phase began an average of 45 minutes after the ingestion of contrast material. Blinded analysis was performed by three abdominal radiologists separately, using a three-point scale (0 = poor, 1 = acceptable, 2 = excellent) to assess the effectiveness of SCC for marking the proximal, middle, and distal small bowel. Average scores for enhancement with SCC and with water were obtained and compared. Statistical analysis was performed with a Wilcoxon signed-rank test. SCC was assigned higher mean scores than water for enhancement in each segment of the bowel, both on early-phase images (0.8-1.35 for SCC vs 0.6-1.1 for water) and on late-phase images (1.1-1.4 vs 0.81-0.96). Bowel marking with SCC, particularly in the jejunum and ileum, also was rated better than that with water in a high percentage of patients. The differences between the scores for water and for SCC, however, were not statistically significant (P > .05). SCC is effective as a negative oral contrast agent for small bowel marking at CT.

  10. TH-C-18A-09: Exam and Patient Parameters Affecting the DNA Damage Response Following CT Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elgart, S; Adibi, A; Bostani, M

    Purpose: To identify exam and patient parameters affecting the biological response to CT studies using in vivo and ex vivo blood samples. Methods: Blood samples were collected under IRB approval from 16 patients undergoing clinically-indicated CT exams. Blood was procured prior to, immediately after and 30minutes following irradiation. A sample of preexam blood was placed on the patient within the exam region for ex vivo analysis. Whole blood samples were fixed immediately following collection and stained for γH2AX to assess DNA damage response (DDR). Median fluorescence of treated samples was compared to non-irradiated control samples for each patient. Patients weremore » characterized by observed biological kinetic response: (a) fast — phosphorylation increased by 2minutes and fell by 30minutes, (b) slow — phosphorylation continued to increase to 30minutes and (c) none — little change was observed or irradiated samples fell below controls. Total dose values were normalized to exam time for an averaged dose-rate in dose/sec for each exam. Relationships between patient biological responses and patient and exam parameters were investigated. Results: A clearer dose response at 30minutes is observed for young patients (<61yoa; R2>0.5) compared to old patients (>61yoa; R{sup 2}<0.11). Fast responding patients were significantly younger than slow responding patients (p<0.05). Unlike in vivo samples, age did not significantly affect the patient response ex vivo. Additionally, fast responding patients received exams with significantly smaller dose-rate than slow responding patients (p<0.05). Conclusion: Age is a significant factor in the biological response suggesting that DDR may be more rapid in a younger population and slower as the population ages. Lack of an agerelated response ex vivo suggests a systemic response to radiation not present when irradiated outside the body. Dose-rate affects the biological response suggesting that patient response may be

  11. Automatic segmentation and co-registration of gated CT angiography datasets: measuring abdominal aortic pulsatility

    NASA Astrophysics Data System (ADS)

    Wentz, Robert; Manduca, Armando; Fletcher, J. G.; Siddiki, Hassan; Shields, Raymond C.; Vrtiska, Terri; Spencer, Garrett; Primak, Andrew N.; Zhang, Jie; Nielson, Theresa; McCollough, Cynthia; Yu, Lifeng

    2007-03-01

    Purpose: To develop robust, novel segmentation and co-registration software to analyze temporally overlapping CT angiography datasets, with an aim to permit automated measurement of regional aortic pulsatility in patients with abdominal aortic aneurysms. Methods: We perform retrospective gated CT angiography in patients with abdominal aortic aneurysms. Multiple, temporally overlapping, time-resolved CT angiography datasets are reconstructed over the cardiac cycle, with aortic segmentation performed using a priori anatomic assumptions for the aorta and heart. Visual quality assessment is performed following automatic segmentation with manual editing. Following subsequent centerline generation, centerlines are cross-registered across phases, with internal validation of co-registration performed by examining registration at the regions of greatest diameter change (i.e. when the second derivative is maximal). Results: We have performed gated CT angiography in 60 patients. Automatic seed placement is successful in 79% of datasets, requiring either no editing (70%) or minimal editing (less than 1 minute; 12%). Causes of error include segmentation into adjacent, high-attenuating, nonvascular tissues; small segmentation errors associated with calcified plaque; and segmentation of non-renal, small paralumbar arteries. Internal validation of cross-registration demonstrates appropriate registration in our patient population. In general, we observed that aortic pulsatility can vary along the course of the abdominal aorta. Pulsation can also vary within an aneurysm as well as between aneurysms, but the clinical significance of these findings remain unknown. Conclusions: Visualization of large vessel pulsatility is possible using ECG-gated CT angiography, partial scan reconstruction, automatic segmentation, centerline generation, and coregistration of temporally resolved datasets.

  12. Predictive value of abdominal CT in evaluating internal herniation after bariatric laparoscopic Roux-en-Y gastric bypass.

    PubMed

    Ederveen, J C; van Berckel, M M G; Nienhuijs, S W; Weber, R J P; Nederend, J

    2018-06-04

    Internal herniation, a serious complication after bariatric surgery, is challenging to diagnose. The aim of this study was to determine the accuracy of abdominal CT in diagnosing internal herniation. The study included consecutive patients who had undergone laparoscopic gastric bypass surgery between 1 January 2011 and 1 January 2015 at a bariatric centre of excellence. To select patients suspected of having internal herniation, reports of abdominal CT and reoperations up to 1 January 2017 were screened. CT was presumed negative for internal herniation if no follow-up CT or reoperation was performed within 90 days after the initial CT, or no internal herniation was found during reoperation. The accuracy of abdominal CT in diagnosing internal herniation was calculated using two-way contingency tables. A total of 1475 patients were included (84·7 per cent women, mean age 46·5 years, median initial BMI 41·8 kg/m 2 ). CT and/or reoperation was performed in 192 patients (13·0 per cent) in whom internal herniation was suspected. Internal herniation was proven laparoscopically in 37 of these patients. The incidence of internal herniation was 2·5 per cent. An analysis by complaint included a total of 265 episodes, for which 247 CT scans were undertaken. CT was not used to investigate 18 episodes, but internal herniation was encountered in one-third of these during reoperation. Combining the follow-up and intraoperative findings, the accuracy of CT for internal herniation had a sensitivity of 83·8 (95 per cent c.i. 67·3 to 93·2) per cent, a specificity of 87·1 (81·7 to 91·2) per cent, a positive predictive value of 53·4 (40·0 to 66·5) per cent and a negative predictive value of 96·8 (92·9 to 98·7) per cent. Abdominal CT is an important tool in diagnosing internal herniation, with a high specificity and a high negative predictive value. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.

  13. The Use of CT Scan in Hemodynamically Stable Children with Blunt Abdominal Trauma: Look before You Leap.

    PubMed

    Nellensteijn, David R; Greuter, Marcel J; El Moumni, Moustafa; Hulscher, Jan B

    2016-08-01

    We set out to determine the diagnostic value of computed tomographic (CT) scans in relation to the radiation dose, tumor incidence, and tumor mortality by radiation for hemodynamically stable pediatric patients with blunt abdominal injury. We focused on the changes in management because of new information obtained by CT. CT scans for suspected pediatric abdominal injury performed in our accident and emergency department were retrieved from the radiology registry and analyzed for: injury and hemodynamic parameters, changes in therapy, and radiological interventions. The dose length product (DLP) was used to calculate the effective dose (ED) and with the BEIR VII report we calculated the estimated induced lifetime tumor and mortality risk. Seventy-two patients underwent abdominal CT scanning for suspicion of abdominal injury and eight patients were excluded for hemodynamic instability, leaving 64 hemodynamically stable patients. Four patients died (6%). On the remaining 60 patients, only one laparotomy was performed for suspicion of duodenal perforation. Only in three out of the 64 hemodynamically stable cases (5%), a CT scan brought forward an indication for intervention or change in management. One patient was suspected of a duodenal perforation and underwent a laparotomy. A grade II hepatic laceration, but no duodenal, injury was found. Two patients underwent embolization of the splenic artery. One for an arterial blush caused by splenic laceration as was observed on the contrast enhanced-CT. Patient remained stable and during the angiogram the blush had disappeared. The second patient underwent (prophylactic) selective arterial embolization for having sustained a grade V splenic injury. The median radiation dosage was 11.43 mSv (range 1.19-23.76 mSv) in our patients. The use of the BEIR VII methodology results in an estimated increase in the lifetime tumor incidence of 0.17% (range, 0.05-0.67%) and an estimated increase in lifetime tumor incidence of 0.08% (0

  14. Computer-aided diagnosis of splenic enlargement using wave pattern of spleen in abdominal CT images

    NASA Astrophysics Data System (ADS)

    Seong, Won; Cho, June-Sik; Noh, Seung-Moo; Park, Jong Won

    2006-03-01

    It is known that the spleen accompanied by liver cirrhosis is hypertrophied or enlarged. We have examined a wave pattern at the left boundary of spleen on the abdominal CT images having liver cirrhosis, and found that they are different from those on the images having a normal liver. It is noticed that the abdominal CT images of patient with liver cirrhosis shows strong bending in the wave pattern. In the case of normal liver, the images may also have a wave pattern, but its bends are not strong. Therefore, the total waving area of the spleen with liver cirrhosis is found to be greater than that of the spleen with a normal liver. Moreover, we found that the waves of the spleen from the image with liver cirrhosis have the higher degree of circularity compared to the normal liver case. Based on the two observations above, we propose an automatic method to diagnose splenic enlargement by using the wave pattern of the spleen in abdominal CT images. The proposed automatic method improves the diagnostic performance compared with the conventional process based on the size of spleen.

  15. New scoring system for intra-abdominal injury diagnosis after blunt trauma.

    PubMed

    Shojaee, Majid; Faridaalaee, Gholamreza; Yousefifard, Mahmoud; Yaseri, Mehdi; Arhami Dolatabadi, Ali; Sabzghabaei, Anita; Malekirastekenari, Ali

    2014-01-01

    An accurate scoring system for intra-abdominal injury (IAI) based on clinical manifestation and examination may decrease unnecessary CT scans, save time, and reduce healthcare cost. This study is designed to provide a new scoring system for a better diagnosis of IAI after blunt trauma. This prospective observational study was performed from April 2011 to October 2012 on patients aged above 18 years and suspected with blunt abdominal trauma (BAT) admitted to the emergency department (ED) of Imam Hussein Hospital and Shohadaye Hafte Tir Hospital. All patients were assessed and treated based on Advanced Trauma Life Support and ED protocol. Diagnosis was done according to CT scan findings, which was considered as the gold standard. Data were gathered based on patient's history, physical exam, ultrasound and CT scan findings by a general practitioner who was not blind to this study. Chi-square test and logistic regression were done. Factors with significant relationship with CT scan were imported in multivariate regression models, where a coefficient (β) was given based on the contribution of each of them. Scoring system was developed based on the obtained total β of each factor. Altogether 261 patients (80.1% male) were enrolled (48 cases of IAI). A 24-point blunt abdominal trauma scoring system (BATSS) was developed. Patients were divided into three groups including low (score<8), moderate (8≤score<12) and high risk (score≥12). In high risk group immediate laparotomy should be done, moderate group needs further assessments, and low risk group should be kept under observation. Low risk patients did not show positive CT-scans (specificity 100%). Conversely, all high risk patients had positive CT-scan findings (sensitivity 100%). The receiver operating characteristic curve indicated a close relationship between the results of CT scan and BATSS (sensitivity=99.3%). The present scoring system furnishes a high precision and reproducible diagnostic tool for BAT

  16. Incidental physiological sliding hiatal hernia: a single center comparison study between CT with water enema and CT colonography.

    PubMed

    Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea

    2015-08-01

    Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate

  17. Fat necrosis after abdominal surgery: A pitfall in interpretation of FDG-PET/CT.

    PubMed

    Davidson, Tima; Lotan, Eyal; Klang, Eyal; Nissan, Johnatan; Goldstein, Jeffrey; Goshen, Elinor; Ben-Haim, Simona; Apter, Sara; Chikman, Bar

    2018-06-01

    We describe FDG-PET/CT findings of postoperative fat necrosis in patients following abdominal surgery, and evaluate their changes in size and FDG uptake over time. FDG-PET/CT scans from January 2007-January 2016 containing the term 'fat necrosis' were reviewed. Lesions meeting radiological criteria of fat necrosis in patients with prior abdominal surgery were included. Forty-four patients, 30 males, mean age 68.4 ± 11.0 years. Surgeries: laparotomy (n=37; 84.1 %), laparoscopy (n=3; 6.8 %), unknown (n=4; 9.1 %). CTs of all lesions included hyperdense well-defined rims surrounding a heterogeneous fatty core. Sites: peritoneum (n=34; 77 %), omental fat (n=19; 43 %), subcutaneous fat (n=8; 18 %), retroperitoneum (n=2; 5 %). Mean lesion long axis: 33.6±24.9 mm (range: 13.0-140.0). Mean SUVmax: 2.6±1.1 (range: 0.6-5.1). On serial CTs (n=34), lesions decreased in size (p=0.022). Serial FDG-PET/CT (n=24) showed no significant change in FDG-avidity (p=0.110). Mean SUVmax did not correlate with time from surgery (p=0.558) or lesion size (p=0.259). Postsurgical fat necrosis demonstrated characteristic CT features and may demonstrate increased FDG uptake. However, follow-up of subsequent imaging scans showed no increases in size or FDG-avidity. Awareness of this entity is important to avoid misinterpretation of findings as recurrent cancer. • Postsurgical fat necrosis may mimic cancer in FDG-PET/CT. • Follow-up of fat necrosis showed no increase in FDG intensity. • CT follow-up showed a decrease in lesion size. • FDG uptake did not correlate with time lapsed from surgery.

  18. Automatic blood vessel based-liver segmentation using the portal phase abdominal CT

    NASA Astrophysics Data System (ADS)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Shimada, Mitsuo; Iinuma, Gen

    2018-02-01

    Liver segmentation is the basis for computer-based planning of hepatic surgical interventions. In diagnosis and analysis of hepatic diseases and surgery planning, automatic segmentation of liver has high importance. Blood vessel (BV) has showed high performance at liver segmentation. In our previous work, we developed a semi-automatic method that segments the liver through the portal phase abdominal CT images in two stages. First stage was interactive segmentation of abdominal blood vessels (ABVs) and subsequent classification into hepatic (HBVs) and non-hepatic (non-HBVs). This stage had 5 interactions that include selective threshold for bone segmentation, selecting two seed points for kidneys segmentation, selection of inferior vena cava (IVC) entrance for starting ABVs segmentation, identification of the portal vein (PV) entrance to the liver and the IVC-exit for classifying HBVs from other ABVs (non-HBVs). Second stage is automatic segmentation of the liver based on segmented ABVs as described in [4]. For full automation of our method we developed a method [5] that segments ABVs automatically tackling the first three interactions. In this paper, we propose full automation of classifying ABVs into HBVs and non- HBVs and consequently full automation of liver segmentation that we proposed in [4]. Results illustrate that the method is effective at segmentation of the liver through the portal abdominal CT images.

  19. Journal club: Acute abdominal pain in elderly patients: effect of radiologist awareness of clinicobiologic information on CT accuracy.

    PubMed

    Millet, Ingrid; Alili, Chakib; Bouic-Pages, Emmanuelle; Curros-Doyon, Fernanda; Nagot, Nicolas; Taourel, Patrice

    2013-12-01

    The purpose of this study was to assess whether the availability of clinicobiologic findings would affect the diagnostic performance of CT of elderly emergency department patients with nontraumatic acute abdominal pain. The cases of 333 consecutively registered patients 75 years old or older presenting to the emergency department with acute abdominal pain and who underwent CT were retrospectively reviewed by two radiologists blinded or not to the patient's clinicobiologic results. Diagnostic accuracy was calculated according to the level of correctly classified cases in both the entire cohort and a surgical subgroup and was compared between readings performed with and without knowledge of the clinicobiologic findings. Agreement between each reading and the reference diagnosis and interobserver agreement were assessed with kappa statistics. In both the entire cohort (87.4% vs 85.3%, p = 0.07) and the surgical group (94% vs 91%, p = 0.15), there was no significant difference in CT accuracy between diagnoses made when the radiologist was aware and those made when the radiologist was not aware of the clinicobiologic findings. Agreement between the CT diagnosis and the final diagnosis was excellent whether or not the radiologist was aware of the clinicobiologic findings. In the care of elderly patients, CT is accurate for diagnosing the cause of acute abdominal pain, particularly when it is of surgical origin, regardless of the availability of clinical and biologic findings. Thus CT interpretation should not be delayed until complete clinicobiologic data are available, and the images should be quickly transmitted to the emergency physician so that appropriate therapy can be begun.

  20. Abdominal multi-organ CT segmentation using organ correlation graph and prediction-based shape and location priors.

    PubMed

    Okada, Toshiyuki; Linguraru, Marius George; Hori, Masatoshi; Summers, Ronald M; Tomiyama, Noriyuki; Sato, Yoshinobu

    2013-01-01

    The paper addresses the automated segmentation of multiple organs in upper abdominal CT data. We propose a framework of multi-organ segmentation which is adaptable to any imaging conditions without using intensity information in manually traced training data. The features of the framework are as follows: (1) the organ correlation graph (OCG) is introduced, which encodes the spatial correlations among organs inherent in human anatomy; (2) the patient-specific organ shape and location priors obtained using OCG enable the estimation of intensity priors from only target data and optionally a number of untraced CT data of the same imaging condition as the target data. The proposed methods were evaluated through segmentation of eight abdominal organs (liver, spleen, left and right kidney, pancreas, gallbladder, aorta, and inferior vena cava) from 86 CT data obtained by four imaging conditions at two hospitals. The performance was comparable to the state-of-the-art method using intensity priors constructed from manually traced data.

  1. [Diagnostic imaging and acute abdominal pain].

    PubMed

    Liljekvist, Mads Svane; Pommergaard, Hans-Christian; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-19

    Acute abdominal pain is a common clinical condition. Clinical signs and symptoms can be difficult to interpret, and diagnostic imaging may help to identify intra-abdominal disease. Conventional X-ray, ultrasound (US) and computed tomography (CT) of the abdomen vary in usability between common surgical causes of acute abdominal pain. Overall, conventional X-ray cannot confidently diagnose or rule out disease. US and CT are equally trustworthy for most diseases. US with subsequent CT may enhance diagnostic precision. Magnetic resonance seems promising for future use in acute abdominal imaging.

  2. Association of Changes in Abdominal Fat and Cardiovascular Risk Factors

    PubMed Central

    Lee, Jane J.; Pedley, Alison; Hoffmann, Udo; Massaro, Joseph M.; Fox, Caroline S.

    2017-01-01

    BACKGROUND Subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) are associated with adverse cardiometabolic risk profiles. OBJECTIVES This study explored the degree to which changes in abdominal fat quantity and quality are associated with changes in cardiovascular disease (CVD) risk factors. METHODS Study participants (n = 1,106; 44.1% women; mean baseline age 45.1 years) were drawn from the Framingham Heart Study Third Generation cohort who participated in the computed tomography (CT) substudy Exams 1 and 2. Participants were followed for 6.1 years on average. Abdominal adipose tissue volume in cm3 and attenuation in Hounsfield units (HU) were determined by CT-acquired abdominal scans. RESULTS The mean fat volume change was an increase of 602 cm3 for SAT and an increase of 703 cm3 for VAT; the mean fat attenuation change was a decrease of 5.5HU for SAT and an increase of 0.07 HU for VAT. An increase in fat volume and decrease in fat attenuation were associated with adverse changes in CVD risk factors. An additional 500 cm3 increase in fat volume was associated with incident hypertension (odds ratio [OR]: 1.21 for SAT; OR: 1.30 for VAT), hypertriglyceridemia (OR: 1.15 for SAT; OR: 1.56 for VAT), and metabolic syndrome (OR: 1.43 for SAT; OR: 1.82 for VAT; all p < 0.05). Similar trends were observed for each additional 5 HU decrease in abdominal adipose tissue attenuation. Most associations remained significant even after further accounting for body mass index change, waist circumference change, or respective abdominal adipose tissue volumes. CONCLUSIONS Increasing accumulation of fat quantity and decreasing fat attenuation are associated with worsening of CVD risk factors beyond the associations with generalized adiposity, central adiposity, or respective adipose tissue volumes. PMID:27687192

  3. Journal club: Renal masses detected at abdominal CT: radiologists' adherence to guidelines regarding management recommendations and communication of critical results.

    PubMed

    Maehara, Cleo K; Silverman, Stuart G; Lacson, Ronilda; Khorasani, Ramin

    2014-10-01

    The purpose of this study was to assess radiologists' adherence to published guidelines for managing renal masses detected at abdominal CT at one institution and to a critical results communication policy. A validated natural language processing tool supplemented by manual review was used to randomly assemble a cohort of 97 radiology reports from all abdominal CT reports (n = 11,952) generated from July 2010 to June 2011. Critical renal mass findings warranted consideration for surgery, intervention, or imaging follow-up and required direct, separate, and timely communication to the referrer in addition to the radiology report. Primary outcomes were adherence to guidelines and institutional policy for communicating critical results. Sample size allowed a 95% CI ± 5% for primary outcome. Pearson chi-square test was performed to assess whether radiology subspecialization was predictive of the primary outcome. Of all abdominal CT reports, 35.6% contained at least one renal mass finding (4.3% critical). Guideline adherence was lower for patients with critical than for those with noncritical findings (48/57 [84.2%] vs 40/40 [100%]; p = 0.01). Adherence to critical result communication policy was 73.7% (42/57). For critical findings, abdominal radiologists had higher guideline adherence (40/43 [93.0%] vs 8/14 [57.1%]; p = 0.001) and critical result communication policy adherence (36/43 [83.7%] vs 6/14 [42.9%]; p = 0.002) than nonabdominal radiologists. In reporting renal masses detected at abdominal CT, radiologists largely adhered to management guidelines but did not adhere to the critical results communication policy in one of four reports. Subspecialization improved adherence to both management guidelines and the institution's critical result communication policy.

  4. Assessing the prevalence and clinical relevance of positive abdominal and pelvic CT findings in senior patients presenting to the emergency department.

    PubMed

    Alabousi, Abdullah; Patlas, Michael N; Meshki, Malek; Monteiro, Sandra; Katz, Douglas S

    2016-04-01

    The purpose of our study was to retrospectively evaluate the prevalence and clinical relevance of positive abdominal and pelvic CT findings for patients 65 years of age and older, when compared with all other scanned adult Emergency Department (ED) patients, at a single tertiary care hospital. Our hypothesis was that there is an increased prevalence and clinical relevance of positive abdominal/pelvic CT findings in senior patients. A research ethics board-approved retrospective review of all adult patients who underwent an emergency CT of the abdomen and pelvis for acute nontraumatic abdominal and/or pelvic signs and symptoms was performed. Two thousand one hundred two patients between October 1, 2011, and September 30, 2013, were reviewed. Six hundred thirty-one patients were included in the <65 group (298 men and 333 women; mean age 46, age range 18-64), and 462 were included in the >65 group (209 men and 253 women; mean age 77.6, age range 65-99). Overall, there were more positive CT findings for patients <65 (389 positive cases, 61.6 %) compared with the >65 group (257 positive cases, 55.6 %), which was a statistically significant difference (p < 0.03). Moreover, with the exception of complicated appendicitis cases, which were more common in the >65 group, there were no statistically significant differences in the clinical/surgical relevance of the positive CT findings between the two groups. The findings of our retrospective study therefore refute our hypothesis that there is an increased prevalence of positive abdominal CT findings in patients >65. This may be related to ED physicians at our institution being more hesitant to order CT examinations for the younger population, presumably due to radiation concerns. However, older patients in our series were more likely to present with complicated appendicitis, and a lower threshold for ordering CT examinations of the abdomen and pelvis in this patient population should therefore be considered.

  5. CT abdominal imaging findings in patients with sickle cell disease: acute vaso-occlusive crisis, complications, and chronic sequelae.

    PubMed

    Gardner, Carly S; Boll, Daniel T; Bhosale, Priya; Jaffe, Tracy A

    2016-12-01

    Sickle cell disease (SCD) is the most prevalent hemoglobinopathy. Survival in patients with SCD has improved over the past few decades. These patients experience a lifetime of repeated acute pain crises, which are thought to result from sickling and microvascular occlusions; acute abdominal pain is common. Moreover, repeated crises often lead to organ dysfunction, such as asplenia, hepatic failure, and renal failure. The spleen, liver, biliary system, kidneys, and gastrointestinal tract can all be affected. Patients may undergo CT to further direct clinical management. We review the spectrum of CT imaging findings of abdominal manifestations in patients with SCD, from the acute microvascular occlusive pain crisis to the potential complications and chronic sequelae.

  6. Reproducibility of abdominal fat assessment by ultrasound and computed tomography.

    PubMed

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.

  7. A new technique for the diagnosis of acute appendicitis: abdominal CT with compression to the right lower quadrant.

    PubMed

    Kılınçer, Abidin; Akpınar, Erhan; Erbil, Bülent; Ünal, Emre; Karaosmanoğlu, Ali Devrim; Kaynaroğlu, Volkan; Akata, Deniz; Özmen, Mustafa

    2017-08-01

    To determine the diagnostic accuracy of abdominal CT with compression to the right lower quadrant (RLQ) in adults with acute appendicitis. 168 patients (age range, 18-78 years) were included who underwent contrast-enhanced CT for suspected appendicitis performed either using compression to the RLQ (n = 71) or a standard protocol (n = 97). Outer diameter of the appendix, appendiceal wall thickening, luminal content and associated findings were evaluated in each patient. Kruskal-Wallis, Fisher's and Pearson's chi-squared tests were used for statistical analysis. There was no significant difference in the mean outer diameter (MOD) between compression CT scans (10.6 ± 1.9 mm) and standard protocol (11.2 ± 2.3 mm) in patients with acute appendicitis (P = 1). MOD was significantly lower in the compression group (5.2 ± 0.8 mm) compared to the standard protocol (6.5 ± 1.1 mm) (P < 0.01) in patients without appendicitis. A cut-off value of 6.75 mm for the outer diameter of the appendix was found to be 100% sensitive in the diagnosis of acute appendicitis for both groups. The specificity was higher for compression CT technique (67.7 vs. 94.9%). Normal appendix diameter was significantly smaller in the compression-CT group compared to standard-CT group, increasing diagnostic accuracy of abdominal compression CT. • Normal appendix diameter is significantly smaller in compression CT. • Compression could force contrast material to flow through the appendiceal lumen. • Compression CT may be a CT counterpart of graded compression US.

  8. Value of a step-up diagnosis plan: CRP and CT-scan to diagnose and manage postoperative complications after major abdominal surgery.

    PubMed

    Straatman, Jennifer; Cuesta, Miguel A; Gisbertz, Suzanne S; Van der Peet, Donald L

    2014-12-01

    Postoperative complications frequently follow major abdominal surgery and are associated with increased morbidity and mortality. Early diagnosis and treatment of complications is associated with improved patient outcome. In this study we assessed the value of a step-up diagnosis plan by C-reactive protein and CT-scan (computed tomography-scan) imaging for detection of postoperative complications following major abdominal surgery.An observational cohort study was conducted of 399 consecutivepatients undergoing major abdominal surgery between January 2009 and January 2011. Indication for operation, type of surgery, postoperative morbidity, complications according to the Clavien-Dindo classification and mortality were recorded. Clinical parameters were recorded until 14 days postoperatively or until discharge. Regular C-reactive protein (CPR) measurements in peripheral blood and on indication -enhanced CT-scans were performed.Eighty-three out of 399 (20.6 %) patients developed a major complication in the postoperative course after a median of seven days (IQR 4-9 days). One hundred and thirty two patients received additional examination consisting of enhanced CT-scan imaging, and treatment by surgical reintervention or intensive care observation. CRP levels were significantly higher in patients with postoperative complications. On the second postoperative dayCRP levels were on average 197.4 mg/L in the uncomplicated group, 220.9 mg/L in patients with a minor complication and 280.1 mg/L in patients with major complications (p < 0,001).CT-scan imaging showed a sensitivity of 91.7 % and specificity of 100 % in diagnosis of major complications. Based on clinical deterioration and the increase of CRP, an additional enhanced CT-scan offered clear discrimination between patients with major abdominal complications and uncomplicated patients. Adequate treatment could then be accomplished.

  9. [Tumoral calcinoses in a chronic hemodialysis patient: The role of SPECT/CT hybrid imaging].

    PubMed

    Matrane, Aboubakr; Hiroual, Soufiane; Bsiss, Mohamed Aziz; Doubli, Safa Bennani

    2018-05-01

    Tumoral calcinosis is a rare benign disease, defined by the presence of calcified deposits in periarticular tissues. It can be hereditary or secondary at chronic renal failure at the stage of dialysis. This work illustrates the contribution of single-photon emission computed tomography (SPECT/CT) in the diagnosis and management of tumoral calcinoses in a chronic hemodialysis patient, based on a clinical case. A 62-year-old patient, chronic hemodialysis since 24 years, presented a mechanical pain shoulders, knees and hips with limitation of joint mobility. The clinical exam found a mass of soft tissue in the buttocks. The radiological exam showed the presence of periarticular calcifications with no bone involvement. The SPECT/CT revealed a multifocal tumoral calcinosis affecting shoulders, elbows, wrists, hips and knees, associated with alveolar and abdominal calcinosis. Tumoral calcinosis is a distinct clinicopathological entity characterised by periarticular soft tissue calcium deposits. The SPECT/CT is important in the diagnosis, the assessment of extension and monitoring of tumoral calcinosis after treatment. Copyright © 2017 Société francophone de néphrologie, dialyse et transplantation. Published by Elsevier Masson SAS. All rights reserved.

  10. A study on automated anatomical labeling to arteries concerning with colon from 3D abdominal CT images

    NASA Astrophysics Data System (ADS)

    Hoang, Bui Huy; Oda, Masahiro; Jiang, Zhengang; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Mori, Kensaku

    2011-03-01

    This paper presents an automated anatomical labeling method of arteries extracted from contrasted 3D CT images based on multi-class AdaBoost. In abdominal surgery, understanding of vasculature related to a target organ such as the colon is very important. Therefore, the anatomical structure of blood vessels needs to be understood by computers in a system supporting abdominal surgery. There are several researches on automated anatomical labeling, but there is no research on automated anatomical labeling to arteries concerning with the colon. The proposed method obtains a tree structure of arteries from the artery region and calculates features values of each branch. These feature values are thickness, curvature, direction, and running vectors of branch. Then, candidate arterial names are computed by classifiers that are trained to output artery names. Finally, a global optimization process is applied to the candidate arterial names to determine final names. Target arteries of this paper are nine lower abdominal arteries (AO, LCIA, RCIA, LEIA, REIA, SMA, IMA, LIIA, RIIA). We applied the proposed method to 14 cases of 3D abdominal contrasted CT images, and evaluated the results by leave-one-out scheme. The average precision and recall rates of the proposed method were 87.9% and 93.3%, respectively. The results of this method are applicable for anatomical name display of surgical simulation and computer aided surgery.

  11. Optimizing working space in porcine laparoscopy: CT measurement of the effects of intra-abdominal pressure.

    PubMed

    Vlot, John; Wijnen, Rene; Stolker, Robert Jan; Bax, Klaas

    2013-05-01

    Several factors may affect volume and dimensions of the working space in laparoscopic surgery. The precise impact of these factors has not been well studied. In a porcine model, we used computed tomographic (CT) scanning for measuring working space volume and distances. In a first series of experiments, we studied the relationship between intra-abdominal pressure (IAP) and working space. Eleven 20 kg pigs were studied under standardized anesthesia and volume-controlled ventilation. Cardiorespiratory parameters were monitored continuously, and blood gas samples were taken at different IAP levels. Respiratory rate was increased when ETCO₂ exceeded 7 kPa. Breath-hold CT scans were made at IAP levels of 0, 5, 10, and 15 mmHg. Insufflator volumes were compared to CT-measured volumes. Maximum dimensions of pneumoperitoneum were measured on reconstructed CT images. Respiratory rate had to be increased in three animals. Mild hypercapnia and acidosis occurred at 15 mmHg IAP. Peak inspiratory pressure rose significantly at 10 and 15 mmHg. CT-measured volume increased relatively by 93 % from 5 to 10 mmHg IAP and by 19 % from 10 to 15 mmHg IAP. Comparing CT volumes to insufflator volumes gave a bias of 76 mL. The limits of agreement were -0.31 to +0.47, a range of 790 mL. The internal anteroposterior diameter increased by 18 % by increasing IAP from 5 to 10 mmHg and by 5 % by increasing IAP from 10 to 15 mmHg. At 15 mmHg, the total relative increase of the pubis-diaphragm distance was only 6 %. Abdominal width did not increase. CT allows for precise calculation of the actual CO₂ pneumoperitoneum volume, whereas the volume of CO₂ released by the insufflator does not. Increasing IAP up to 10 mmHg achieved most gain in volume and in internal anteroposterior diameter. At an IAP of 10 mmHg, higher peak inspiratory pressure was significantly elevated.

  12. Efficient multi-atlas abdominal segmentation on clinically acquired CT with SIMPLE context learning.

    PubMed

    Xu, Zhoubing; Burke, Ryan P; Lee, Christopher P; Baucom, Rebeccah B; Poulose, Benjamin K; Abramson, Richard G; Landman, Bennett A

    2015-08-01

    Abdominal segmentation on clinically acquired computed tomography (CT) has been a challenging problem given the inter-subject variance of human abdomens and complex 3-D relationships among organs. Multi-atlas segmentation (MAS) provides a potentially robust solution by leveraging label atlases via image registration and statistical fusion. We posit that the efficiency of atlas selection requires further exploration in the context of substantial registration errors. The selective and iterative method for performance level estimation (SIMPLE) method is a MAS technique integrating atlas selection and label fusion that has proven effective for prostate radiotherapy planning. Herein, we revisit atlas selection and fusion techniques for segmenting 12 abdominal structures using clinically acquired CT. Using a re-derived SIMPLE algorithm, we show that performance on multi-organ classification can be improved by accounting for exogenous information through Bayesian priors (so called context learning). These innovations are integrated with the joint label fusion (JLF) approach to reduce the impact of correlated errors among selected atlases for each organ, and a graph cut technique is used to regularize the combined segmentation. In a study of 100 subjects, the proposed method outperformed other comparable MAS approaches, including majority vote, SIMPLE, JLF, and the Wolz locally weighted vote technique. The proposed technique provides consistent improvement over state-of-the-art approaches (median improvement of 7.0% and 16.2% in DSC over JLF and Wolz, respectively) and moves toward efficient segmentation of large-scale clinically acquired CT data for biomarker screening, surgical navigation, and data mining. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Reproducibility of abdominal fat assessment by ultrasound and computed tomography

    PubMed Central

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024

  14. Computer-aided Assessment of Regional Abdominal Fat with Food Residue Removal in CT

    PubMed Central

    Makrogiannis, Sokratis; Caturegli, Giorgio; Davatzikos, Christos; Ferrucci, Luigi

    2014-01-01

    Rationale and Objectives Separate quantification of abdominal subcutaneous and visceral fat regions is essential to understand the role of regional adiposity as risk factor in epidemiological studies. Fat quantification is often based on computed tomography (CT) because fat density is distinct from other tissue densities in the abdomen. However, the presence of intestinal food residues with densities similar to fat may reduce fat quantification accuracy. We introduce an abdominal fat quantification method in CT with interest in food residue removal. Materials and Methods Total fat was identified in the feature space of Hounsfield units and divided into subcutaneous and visceral components using model-based segmentation. Regions of food residues were identified and removed from visceral fat using a machine learning method integrating intensity, texture, and spatial information. Cost-weighting and bagging techniques were investigated to address class imbalance. Results We validated our automated food residue removal technique against semimanual quantifications. Our feature selection experiments indicated that joint intensity and texture features produce the highest classification accuracy at 95%. We explored generalization capability using k-fold cross-validation and receiver operating characteristic (ROC) analysis with variable k. Losses in accuracy and area under ROC curve between maximum and minimum k were limited to 0.1% and 0.3%. We validated tissue segmentation against reference semimanual delineations. The Dice similarity scores were as high as 93.1 for subcutaneous fat and 85.6 for visceral fat. Conclusions Computer-aided regional abdominal fat quantification is a reliable computational tool for large-scale epidemiological studies. Our proposed intestinal food residue reduction scheme is an original contribution of this work. Validation experiments indicate very good accuracy and generalization capability. PMID:24119354

  15. Computer-aided assessment of regional abdominal fat with food residue removal in CT.

    PubMed

    Makrogiannis, Sokratis; Caturegli, Giorgio; Davatzikos, Christos; Ferrucci, Luigi

    2013-11-01

    Separate quantification of abdominal subcutaneous and visceral fat regions is essential to understand the role of regional adiposity as risk factor in epidemiological studies. Fat quantification is often based on computed tomography (CT) because fat density is distinct from other tissue densities in the abdomen. However, the presence of intestinal food residues with densities similar to fat may reduce fat quantification accuracy. We introduce an abdominal fat quantification method in CT with interest in food residue removal. Total fat was identified in the feature space of Hounsfield units and divided into subcutaneous and visceral components using model-based segmentation. Regions of food residues were identified and removed from visceral fat using a machine learning method integrating intensity, texture, and spatial information. Cost-weighting and bagging techniques were investigated to address class imbalance. We validated our automated food residue removal technique against semimanual quantifications. Our feature selection experiments indicated that joint intensity and texture features produce the highest classification accuracy at 95%. We explored generalization capability using k-fold cross-validation and receiver operating characteristic (ROC) analysis with variable k. Losses in accuracy and area under ROC curve between maximum and minimum k were limited to 0.1% and 0.3%. We validated tissue segmentation against reference semimanual delineations. The Dice similarity scores were as high as 93.1 for subcutaneous fat and 85.6 for visceral fat. Computer-aided regional abdominal fat quantification is a reliable computational tool for large-scale epidemiological studies. Our proposed intestinal food residue reduction scheme is an original contribution of this work. Validation experiments indicate very good accuracy and generalization capability. Published by Elsevier Inc.

  16. Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience

    PubMed Central

    Pourmorteza, Amir; Symons, Rolf; Sandfort, Veit; Mallek, Marissa; Fuld, Matthew K.; Henderson, Gregory; Jones, Elizabeth C.; Malayeri, Ashkan A.; Folio, Les R.

    2016-01-01

    Purpose To evaluate the performance of a prototype photon-counting detector (PCD) computed tomography (CT) system for abdominal CT in humans and to compare the results with a conventional energy-integrating detector (EID). Materials and Methods The study was HIPAA-compliant and institutional review board–approved with informed consent. Fifteen asymptomatic volunteers (seven men; mean age, 58.2 years ± 9.8 [standard deviation]) were prospectively enrolled between September 2 and November 13, 2015. Radiation dose–matched delayed contrast agent–enhanced spiral and axial abdominal EID and PCD scans were acquired. Spiral images were scored for image quality (Wilcoxon signed-rank test) in five regions of interest by three radiologists blinded to the detector system, and the axial scans were used to assess Hounsfield unit accuracy in seven regions of interest (paired t test). Intraclass correlation coefficient (ICC) was used to assess reproducibility. PCD images were also used to calculate iodine concentration maps. Spatial resolution, noise-power spectrum, and Hounsfield unit accuracy of the systems were estimated by using a CT phantom. Results In both systems, scores were similar for image quality (median score, 4; P = .19), noise (median score, 3; P = .30), and artifact (median score, 1; P = .17), with good interrater agreement (image quality, noise, and artifact ICC: 0.84, 0.88, and 0.74, respectively). Hounsfield unit values, spatial resolution, and noise-power spectrum were also similar with the exception of mean Hounsfield unit value in the spinal canal, which was lower in the PCD than the EID images because of beam hardening (20 HU vs 36.5 HU; P < .001). Contrast-to-noise ratio of enhanced kidney tissue was improved with PCD iodine mapping compared with EID (5.2 ± 1.3 vs 4.0 ± 1.3; P < .001). Conclusion The performance of PCD showed no statistically significant difference compared with EID when the abdomen was evaluated in a conventional scan mode. PCD

  17. Abdominal aortic aneurysm neck remodeling after open aneurysm repair.

    PubMed

    Falkensammer, Juergen; Oldenburg, W Andrew; Biebl, Matthias; Hugl, Beate; Hakaim, Albert G; Crook, Julia E; Berland, Todd L; Paz-Fumagalli, Ricardo

    2007-05-01

    Proximal endovascular aortic graft fixation and maintenance of hemostatic seal depends on the long-term stability of the aortic neck. Previous investigations of aortic neck dilation mostly focused on the infrarenal aortic diameter. Fenestrated and branched stent grafts facilitate suprarenal graft fixation and may thereby improve the long-term integrity of the aortic attachment site. For these devices, the natural history of the suprarenal aortic segment is also of interest. We investigated the natural history of the supra- and infrarenal aortic segment after open abdominal aortic aneurysm (AAA) repair. For this retrospective analysis, we reviewed the preoperative and the initial postoperative as well as the most recent CT series that were obtained from 52 patients undergoing conventional repair of an infrarenal abdominal aortic aneurysm between January 1998 and December 2002. Measurements were performed using electronic calipers on a "split screen", allowing direct comparison of subsequent CT series at corresponding levels along the vessel. Main outcome measures were changes in postoperative measures of the supra- and infrarenal aortic diameters. The first postoperative exam was at a mean (+/-SD) of 7.0 +/- 3.5 months, and the final exams were at 44.4 +/- 21 months. Over this time period, the estimated rate of change in suprarenal diameter was 0.18 mm/ y with 95% confidence interval (CI) from 0.08 to 0.27. The estimated rate of change for the infrarenal diameter was 0.16 (95% CI: 0.05 to 0.27). A clinically relevant diameter increase of >or=3 mm was observed in seven patients (13%). There was evidence of larger diameter increases associated with larger AAA diameters (P = .003 and <.001 for suprarenal and infrarenal diameters), an inverted funnel shape (P = .002 and <.001), and marginal evidence of association with a history of inguinal hernia (P = .043 and .066). Although there is statistically significant evidence of increases in the supra- and infrarenal aortic

  18. Immersive Virtual Reality for Visualization of Abdominal CT.

    PubMed

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A; Bodenheimer, Robert E

    2013-03-28

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two-dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  19. Immersive virtual reality for visualization of abdominal CT

    NASA Astrophysics Data System (ADS)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A.; Bodenheimer, Robert E.

    2013-03-01

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  20. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.

    PubMed

    Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter

    2002-03-01

    We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.

  1. Unusual case of acute appendicitis with left upper quadrant abdominal pain.

    PubMed

    Tawk, Charbel M; Zgheib, Rana R; Mehanna, Seba

    2012-01-01

    Acute appendicitis is one of the most frequent causes of surgical abdominal pain presenting to the Emergency Department. The diagnosis is confirmed by a set of clinical signs, blood tests and imaging. The typical presentation consists of periumbilical pain radiating to the right lower quadrant with peritoneal reaction on palpation (Mac Burney). In this article, we report a case of acute appendicitis presenting with a left upper quadrant pain due to intestinal malrotation and we describe the radiologic findings on computed tomography. With an Alvarado score of 4 and a nonconclusive abdominal U/S, the diagnosis of acute appendicitis was a long shot. Persistence of pain and increasing inflammatory parameters in her blood exams pushed the medical team to further investigate and a CT scan revealed intestinal malrotation with acute appendicitis. An examining physician should not be mislead by the atypical presentation of acute appendicitis and should bear in mind the diagnosis to avoid serious complications. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  2. Evaluation of an iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose.

    PubMed

    Aurumskjöld, Marie-Louise; Söderberg, Marcus; Stålhammar, Fredrik; von Steyern, Kristina Vult; Tingberg, Anders; Ydström, Kristina

    2018-06-01

    Background In pediatric patients, computed tomography (CT) is important in the medical chain of diagnosing and monitoring various diseases. Because children are more radiosensitive than adults, they require minimal radiation exposure. One way to achieve this goal is to implement new technical solutions, like iterative reconstruction. Purpose To evaluate the potential of a new, iterative, model-based method for reconstructing (IMR) pediatric abdominal CT at a low radiation dose and determine whether it maintains or improves image quality, compared to the current reconstruction method. Material and Methods Forty pediatric patients underwent abdominal CT. Twenty patients were examined with the standard dose settings and 20 patients were examined with a 32% lower radiation dose. Images from the standard examination were reconstructed with a hybrid iterative reconstruction method (iDose 4 ), and images from the low-dose examinations were reconstructed with both iDose 4 and IMR. Image quality was evaluated subjectively by three observers, according to modified EU image quality criteria, and evaluated objectively based on the noise observed in liver images. Results Visual grading characteristics analyses showed no difference in image quality between the standard dose examination reconstructed with iDose 4 and the low dose examination reconstructed with IMR. IMR showed lower image noise in the liver compared to iDose 4 images. Inter- and intra-observer variance was low: the intraclass coefficient was 0.66 (95% confidence interval = 0.60-0.71) for the three observers. Conclusion IMR provided image quality equivalent or superior to the standard iDose 4 method for evaluating pediatric abdominal CT, even with a 32% dose reduction.

  3. The utility of focused abdominal ultrasound in blunt abdominal trauma: a reappraisal.

    PubMed

    Helling, Thomas S; Wilson, Jennifer; Augustosky, Kim

    2007-12-01

    Focused assessment with sonography for trauma (FAST) has become commonplace in the management of blunt abdominal trauma. However, newer computed tomography (CT) scanners have decreased imaging time for trauma patients and provide more detailed examination of abdominal contents. It was the aim of the current study to evaluate practice patterns of FAST and abdominal CT in blunt trauma victims. This was a retrospective study of all blunt trauma patients (N = 299) who received at least 1 FAST examination in the emergency department by surgeons and were admitted. Patients were tracked for subsequent CT scanning, disposition from the emergency department, any operative findings, and survival. Twenty-one of 299 patients (7%) had a positive FAST. There were 7 deaths and 14 patients were taken directly to the operating room (OR) for control of abdominal bleeding. Thirty-one of 299 (10%) had equivocal FAST. There were 4 deaths and 8 patients were taken to the OR for control of abdominal bleeding. A total of 247 of the 299 patients had a negative FAST. CT scans were performed in 193: 15 showed a visceral injury. There were 13 deaths and 29 patients were taken to the OR (4 for bleeding). Patients with a positive FAST had a higher mortality than FAST-negative patients (P < .001) and greater likelihood for operation (P < .001). Those with equivocal FAST had a greater likelihood for operation than FAST-negative patients (P < .05). FAST examinations can identify patients at risk for hemorrhage and in whom operation may be needed and, therefore, can guide mobilization of hospital resources. FAST-negative patients can be managed expectantly, using more specific imaging techniques.

  4. Technique and outcomes of laparoscopic bulge repair after abdominal free flap reconstruction.

    PubMed

    Lee, Johnson C; Whipple, Lauren A; Binetti, Brian; Singh, T Paul; Agag, Richard

    2016-01-21

    Bulges and hernias after abdominal free flap surgery are uncommon with rates ranging from as low as 0-36%. In the free flap breast reconstruction population, there are no clear guidelines or optimal strategies to treating postoperative bulges. We describe our minimally invasive technique and outcomes in managing bulge complications in abdominal free flap breast reconstruction patients. A retrospective review was performed on all abdominal free flap breast reconstruction patients at Albany Medical Center from 2011 to 2014. All patients with bulges on clinical exam underwent abdominal CT imaging prior to consultation with a minimally invasive surgeon. Confirmed symptomatic bulges were repaired laparoscopically and patients were monitored regularly in the outpatient setting. Sixty-two patients received a total of 80 abdominal free flap breast reconstructions. Flap types included 41 deep inferior epigastric perforator (DIEP), 36 muscle-sparing transverse rectus abdominus myocutaneous (msTRAM), 2 superficial inferior epigastric artery, and 1 transverse rectus abdominus myocutaneous flap. There were a total of 9 (14.5%) bulge complications, with the majority of patients having undergone msTRAM or DIEP reconstruction. There were no complications, revisions, or recurrences from laparoscopic bulge repair after an average follow-up of 181 days. Although uncommon, bulge formation after abdominal free flap reconstruction can create significant morbidity to patients. Laproscopic hernia repair using composite mesh underlay offers an alternative to traditional open hernia repair and can be successfully used to minimize scarring, infection, and pain to free flap patients who have already undergone significant reconstructive procedures. © 2016 Wiley Periodicals, Inc. Microsurgery, 2016. © 2016 Wiley Periodicals, Inc.

  5. Pancreas segmentation from 3D abdominal CT images using patient-specific weighted subspatial probabilistic atlases

    NASA Astrophysics Data System (ADS)

    Karasawa, Kenichi; Oda, Masahiro; Hayashi, Yuichiro; Nimura, Yukitaka; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Rueckert, Daniel; Mori, Kensaku

    2015-03-01

    Abdominal organ segmentations from CT volumes are now widely used in the computer-aided diagnosis and surgery assistance systems. Among abdominal organs, the pancreas is especially difficult to segment because of its large individual differences of the shape and position. In this paper, we propose a new pancreas segmentation method from 3D abdominal CT volumes using patient-specific weighted-subspatial probabilistic atlases. First of all, we perform normalization of organ shapes in training volumes and an input volume. We extract the Volume Of Interest (VOI) of the pancreas from the training volumes and an input volume. We divide each training VOI and input VOI into some cubic regions. We use a nonrigid registration method to register these cubic regions of the training VOI to corresponding regions of the input VOI. Based on the registration results, we calculate similarities between each cubic region of the training VOI and corresponding region of the input VOI. We select cubic regions of training volumes having the top N similarities in each cubic region. We subspatially construct probabilistic atlases weighted by the similarities in each cubic region. After integrating these probabilistic atlases in cubic regions into one, we perform a rough-to-precise segmentation of the pancreas using the atlas. The results of the experiments showed that utilization of the training volumes having the top N similarities in each cubic region led good results of the pancreas segmentation. The Jaccard Index and the average surface distance of the result were 58.9% and 2.04mm on average, respectively.

  6. ASSESSMENT OF CLINICAL IMAGE QUALITY IN PAEDIATRIC ABDOMINAL CT EXAMINATIONS: DEPENDENCY ON THE LEVEL OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION (ASiR) AND THE TYPE OF CONVOLUTION KERNEL.

    PubMed

    Larsson, Joel; Båth, Magnus; Ledenius, Kerstin; Caisander, Håkan; Thilander-Klang, Anne

    2016-06-01

    The purpose of this study was to investigate the effect of different combinations of convolution kernel and the level of Adaptive Statistical iterative Reconstruction (ASiR™) on diagnostic image quality as well as visualisation of anatomical structures in paediatric abdominal computed tomography (CT) examinations. Thirty-five paediatric patients with abdominal pain with non-specified pathology undergoing abdominal CT were included in the study. Transaxial stacks of 5-mm-thick images were retrospectively reconstructed at various ASiR levels, in combination with three convolution kernels. Four paediatric radiologists rated the diagnostic image quality and the delineation of six anatomical structures in a blinded randomised visual grading study. Image quality at a given ASiR level was found to be dependent on the kernel, and a more edge-enhancing kernel benefitted from a higher ASiR level. An ASiR level of 70 % together with the Soft™ or Standard™ kernel was suggested to be the optimal combination for paediatric abdominal CT examinations. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Automatic multi-label annotation of abdominal CT images using CBIR

    NASA Astrophysics Data System (ADS)

    Xue, Zhiyun; Antani, Sameer; Long, L. Rodney; Thoma, George R.

    2017-03-01

    We present a technique to annotate multiple organs shown in 2-D abdominal/pelvic CT images using CBIR. This annotation task is motivated by our research interests in visual question-answering (VQA). We aim to apply results from this effort in Open-iSM, a multimodal biomedical search engine developed by the National Library of Medicine (NLM). Understanding visual content of biomedical images is a necessary step for VQA. Though sufficient annotational information about an image may be available in related textual metadata, not all may be useful as descriptive tags, particularly for anatomy on the image. In this paper, we develop and evaluate a multi-label image annotation method using CBIR. We evaluate our method on two 2-D CT image datasets we generated from 3-D volumetric data obtained from a multi-organ segmentation challenge hosted in MICCAI 2015. Shape and spatial layout information is used to encode visual characteristics of the anatomy. We adapt a weighted voting scheme to assign multiple labels to the query image by combining the labels of the images identified as similar by the method. Key parameters that may affect the annotation performance, such as the number of images used in the label voting and the threshold for excluding labels that have low weights, are studied. The method proposes a coarse-to-fine retrieval strategy which integrates the classification with the nearest-neighbor search. Results from our evaluation (using the MICCAI CT image datasets as well as figures from Open-i) are presented.

  8. A Flexible Method for Multi-Material Decomposition of Dual-Energy CT Images.

    PubMed

    Mendonca, Paulo R S; Lamb, Peter; Sahani, Dushyant V

    2014-01-01

    The ability of dual-energy computed-tomographic (CT) systems to determine the concentration of constituent materials in a mixture, known as material decomposition, is the basis for many of dual-energy CT's clinical applications. However, the complex composition of tissues and organs in the human body poses a challenge for many material decomposition methods, which assume the presence of only two, or at most three, materials in the mixture. We developed a flexible, model-based method that extends dual-energy CT's core material decomposition capability to handle more complex situations, in which it is necessary to disambiguate among and quantify the concentration of a larger number of materials. The proposed method, named multi-material decomposition (MMD), was used to develop two image analysis algorithms. The first was virtual unenhancement (VUE), which digitally removes the effect of contrast agents from contrast-enhanced dual-energy CT exams. VUE has the ability to reduce patient dose and improve clinical workflow, and can be used in a number of clinical applications such as CT urography and CT angiography. The second algorithm developed was liver-fat quantification (LFQ), which accurately quantifies the fat concentration in the liver from dual-energy CT exams. LFQ can form the basis of a clinical application targeting the diagnosis and treatment of fatty liver disease. Using image data collected from a cohort consisting of 50 patients and from phantoms, the application of MMD to VUE and LFQ yielded quantitatively accurate results when compared against gold standards. Furthermore, consistent results were obtained across all phases of imaging (contrast-free and contrast-enhanced). This is of particular importance since most clinical protocols for abdominal imaging with CT call for multi-phase imaging. We conclude that MMD can successfully form the basis of a number of dual-energy CT image analysis algorithms, and has the potential to improve the clinical utility

  9. Association of Changes in Abdominal Fat Quantity and Quality With Incident Cardiovascular Disease Risk Factors.

    PubMed

    Lee, Jane J; Pedley, Alison; Hoffmann, Udo; Massaro, Joseph M; Fox, Caroline S

    2016-10-04

    Subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) are associated with adverse cardiometabolic risk profiles. This study explored the degree to which changes in abdominal fat quantity and quality are associated with changes in cardiovascular disease (CVD) risk factors. Study participants (n = 1,106; 44.1% women; mean baseline age 45.1 years) were drawn from the Framingham Heart Study Third Generation cohort who participated in the computed tomography (CT) substudy Exams 1 and 2. Participants were followed for 6.1 years on average. Abdominal adipose tissue volume in cm(3) and attenuation in Hounsfield units (HU) were determined by CT-acquired abdominal scans. The mean fat volume change was an increase of 602 cm(3) for SAT and an increase of 703 cm(3) for VAT; the mean fat attenuation change was a decrease of 5.5 HU for SAT and an increase of 0.07 HU for VAT. An increase in fat volume and decrease in fat attenuation were associated with adverse changes in CVD risk factors. An additional 500 cm(3) increase in fat volume was associated with incident hypertension (odds ratio [OR]: 1.21 for SAT; OR: 1.30 for VAT), hypertriglyceridemia (OR: 1.15 for SAT; OR: 1.56 for VAT), and metabolic syndrome (OR: 1.43 for SAT; OR: 1.82 for VAT; all p < 0.05). Similar trends were observed for each additional 5 HU decrease in abdominal adipose tissue attenuation. Most associations remained significant even after further accounting for body mass index change, waist circumference change, or respective abdominal adipose tissue volumes. Increasing accumulation of fat quantity and decreasing fat attenuation are associated with worsening of CVD risk factors beyond the associations with generalized adiposity, central adiposity, or respective adipose tissue volumes. Published by Elsevier Inc.

  10. A Method for the Automatic Exposure Control in Pediatric Abdominal CT: Application to the Standard Deviation Value and Tube Current Methods by Using Patient's Age and Body Size.

    PubMed

    Furuya, Ken; Akiyama, Shinji; Nambu, Atushi; Suzuki, Yutaka; Hasebe, Yuusuke

    2017-01-01

    We aimed to apply the pediatric abdominal CT protocol of Donnelly et al. in the United States to the pediatric abdominal CT-AEC. Examining CT images of 100 children, we found that the sectional area of the hepatic portal region (y) was strongly correlated with the body weight (x) as follows: y=7.14x + 84.39 (correlation coefficient=0.9574). We scanned an elliptical cone phantom that simulates the human body using a pediatric abdominal CT scanning method of Donnelly et al. in, and measured SD values. We further scanned the same phantom under the settings for adult CT-AEC scan and obtained the relationship between the sectional areas (y) and the SD values. Using these results, we obtained the following preset noise factors for CT-AEC at each body weight range: 6.90 at 4.5-8.9 kg, 8.40 at 9.0-17.9 kg, 8.68 at 18.0-26.9 kg, 9.89 at 27.0-35.9 kg, 12.22 at 36.0-45.0 kg, 13.52 at 45.1-70.0 kg, 15.29 at more than 70 kg. From the relation between age, weight and the distance of liver and tuber ischiadicum of 500 children, we obtained the CTDI vol values and DLP values under the scanning protocol of Donnelly et al. Almost all of DRL from these values turned out to be smaller than the DRL data of IAEA and various countries. Thus, by setting the maximum current values of CT-AEC to be the Donnelly et al.'s age-wise current values, and using our weight-wise noise factors, we think we can perform pediatric abdominal CT-AEC scans that are consistent with the same radiation safety and the image quality as those proposed by Donnelly et al.

  11. Traumatic abdominal hernia complicated by necrotizing fasciitis.

    PubMed

    Martínez-Pérez, Aleix; Garrigós-Ortega, Gonzalo; Gómez-Abril, Segundo Ángel; Martí-Martínez, Eva; Torres-Sánchez, Teresa

    2014-11-01

    Necrotizing fasciitis is a critical illness involving skin and soft tissues, which may develop after blunt abdominal trauma causing abdominal wall hernia and representing a great challenge for physicians. A 52-year-old man was brought to the emergency department after a road accident, presenting blunt abdominal trauma with a large non-reducible mass in the lower-right abdomen. A first, CT showed abdominal hernia without signs of complication. Three hours after ICU admission, he developed hemodynamic instability. Therefore, a new CT scan was requested, showing signs of hernia complication. He was moved to the operating room where a complete transversal section of an ileal loop was identified. Five hours after surgery, he presented a new episode of hemodynamic instability with signs of skin and soft tissue infection. Due to the high clinical suspicion of necrotizing fasciitis development, wide debridement was performed. Following traumatic abdominal wall hernia (TAWH), patients can present unsuspected injuries in abdominal organs. Helical CT can be falsely negative in the early moments, leading to misdiagnosis. Necrotizing fasciitis is a potentially fatal infection and, consequently, resuscitation measures, wide-spectrum antibiotics, and early surgical debridement are required. This type of fasciitis can develop after blunt abdominal trauma following wall hernia without skin disruption.

  12. Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters.

    PubMed

    Kalra, Mannudeep K; Maher, Michael M; Blake, Michael A; Lucey, Brian C; Karau, Kelly; Toth, Thomas L; Avinash, Gopal; Halpern, Elkan F; Saini, Sanjay

    2004-09-01

    To assess the effect of noise reduction filters on detection and characterization of lesions on low-radiation-dose abdominal computed tomographic (CT) images. Low-dose CT images of abdominal lesions in 19 consecutive patients (11 women, eight men; age range, 32-78 years) were obtained at reduced tube currents (120-144 mAs). These baseline low-dose CT images were postprocessed with six noise reduction filters; the resulting postprocessed images were then randomly assorted with baseline images. Three radiologists performed independent evaluation of randomized images for presence, number, margins, attenuation, conspicuity, calcification, and enhancement of lesions, as well as image noise. Side-by-side comparison of baseline images with postprocessed images was performed by using a five-point scale for assessing lesion conspicuity and margins, image noise, beam hardening, and diagnostic acceptability. Quantitative noise and contrast-to-noise ratio were obtained for all liver lesions. Statistical analysis was performed by using the Wilcoxon signed rank test, Student t test, and kappa test of agreement. Significant reduction of noise was observed in images postprocessed with filter F compared with the noise in baseline nonfiltered images (P =.004). Although the number of lesions seen on baseline images and that seen on postprocessed images were identical, lesions were less conspicuous on postprocessed images than on baseline images. A decrease in quantitative image noise and contrast-to-noise ratio for liver lesions was noted with all noise reduction filters. There was good interobserver agreement (kappa = 0.7). Although the use of currently available noise reduction filters improves image noise and ameliorates beam-hardening artifacts at low-dose CT, such filters are limited by a compromise in lesion conspicuity and appearance in comparison with lesion conspicuity and appearance on baseline low-dose CT images. Copyright RSNA, 2004

  13. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique.

    PubMed

    Kwon, Heejin; Cho, Jinhan; Oh, Jongyeong; Kim, Dongwon; Cho, Junghyun; Kim, Sanghyun; Lee, Sangyun; Lee, Jihyun

    2015-10-01

    To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. 27 consecutive patients (mean body mass index: 23.55 kg m(-2) underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19-49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. This study represents the first clinical research experiment to use ASIR-V, the newest version of

  14. Contrast-Enhanced Abdominal Angiographic CT for Intra-abdominal Tumor Embolization: A New Tool for Vessel and Soft Tissue Visualization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Bernhard Christian, E-mail: bernhard.meyer@charite.de; Frericks, Bernd Benedikt; Albrecht, Thomas

    2007-07-15

    C-Arm cone-beam computed tomography (CACT), is a relatively new technique that uses data acquired with a flat-panel detector C-arm angiography system during an interventional procedure to reconstruct CT-like images. The purpose of this Technical Note is to present the technique, feasibility, and added value of CACT in five patients who underwent abdominal transarterial chemoembolization procedures. Target organs for the chemoembolizations were kidney, liver, and pancreas and a liposarcoma infiltrating the duodenum. The time for patient positioning, C-arm and system preparation, CACT raw data acquisition, and data reconstruction for a single CACT study ranged from 6 to 12 min. The volumemore » data set produced by the workstation was interactively reformatted using maximum intensity projections and multiplanar reconstructions. As part of an angiography system CACT provided essential information on vascular anatomy, therapy endpoints, and immediate follow-up during and immediately after the abdominal interventions without patient transfer. The quality of CACT images was sufficient to influence the course of treatment. This technology has the potential to expedite any interventional procedure that requires three-dimensional information and navigation.« less

  15. Patient characteristics associated with differences in radiation exposure from pediatric abdomen-pelvis CT scans: a quantile regression analysis.

    PubMed

    Cooper, Jennifer N; Lodwick, Daniel L; Adler, Brent; Lee, Choonsik; Minneci, Peter C; Deans, Katherine J

    2017-06-01

    Computed tomography (CT) is a widely used diagnostic tool in pediatric medicine. However, due to concerns regarding radiation exposure, it is essential to identify patient characteristics associated with higher radiation burden from CT imaging, in order to more effectively target efforts towards dose reduction. Our objective was to identify the effects of various demographic and clinical patient characteristics on radiation exposure from single abdomen/pelvis CT scans in children. CT scans performed at our institution between January 2013 and August 2015 in patients under 16 years of age were processed using a software tool that estimates patient-specific organ and effective doses and merges these estimates with data from the electronic health record and billing record. Quantile regression models at the 50th, 75th, and 90th percentiles were used to estimate the effects of patients' demographic and clinical characteristics on effective dose. 2390 abdomen/pelvis CT scans (median effective dose 1.52mSv) were included. Of all characteristics examined, only older age, female gender, higher BMI, and whether the scan was a multiphase exam or an exam that required repeating for movement were significant predictors of higher effective dose at each quantile examined (all p<0.05). The effects of obesity and multiphase or repeat scanning on effective dose were magnified in higher dose scans. Older age, female gender, obesity, and multiphase or repeat scanning are all associated with increased effective dose from abdomen/pelvis CT. Targeted efforts to reduce dose from abdominal CT in these groups should be undertaken. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The Value of Restaging With Chest and Abdominal CT/MRI Scan After Neoadjuvant Chemoradiotherapy for Locally Advanced Rectal Cancer.

    PubMed

    Liu, Guo-Chen; Zhang, Xu; Xie, E; An, Xin; Cai, Pei-Qiang; Zhu, Ying; Tang, Jing-Hua; Kong, Ling-Heng; Lin, Jun-Zhong; Pan, Zhi-Zhong; Ding, Pei-Rong

    2015-11-01

    Little was known with regard to the value of preoperative systemic restaging for patients with locally advanced rectal cancer (LARC) treated with neoadjuvant chemoradiotherapy (CRT). This study was designed to evaluate the role of chest and abdominal computed tomography (CT) scan or magnetic resonance imaging (MRI) on preoperative restaging in LARC after neoadjuvant CRT and to assess the impact on treatment strategy.Between January 2007 and April 2013, 386 newly diagnosed consecutive patients with LARC who underwent neoadjuvant CRT and received restaging with chest and abdominal CT/MRI scan were included. Imaging results before and after CRT were analyzed.Twelve patients (3.1%) (6 liver lesions, 2 peritoneal lesions, 2 distant lymph node lesions, 1 lung lesions, 1 liver and lung lesions) were diagnosed as suspicious metastases on the restaging scan after radiotherapy. Seven patients (1.8%) were confirmed as metastases by pathology or long-term follow-up. The treatment strategy was changed in 5 of the 12 patients as a result of restaging CT/MRI findings. Another 10 patients (2.6%) who present with normal restaging imaging findings were diagnosed as metastases intra-operatively. The sensitivity, specificity accuracy, negative predictive value, and positive predictive values of restaging CT/MRI was 41.4%, 98.6%, 58.3%, and 97.3%, respectively.The low incidence of metastases and minimal consequences for the treatment plan question the clinical value of routine restaging of chest and abdomen after neoadjuvant CRT. Based on this study, a routine restaging CT/MRI of chest and abdomen in patients with rectal cancer after neoadjuvant CRT is not advocated, carcino-embryonic antigen (CEA) -guided CT/MRI restaging might be an alternative.

  17. 3D marker-controlled watershed for kidney segmentation in clinical CT exams.

    PubMed

    Wieclawek, Wojciech

    2018-02-27

    Image segmentation is an essential and non trivial task in computer vision and medical image analysis. Computed tomography (CT) is one of the most accessible medical examination techniques to visualize the interior of a patient's body. Among different computer-aided diagnostic systems, the applications dedicated to kidney segmentation represent a relatively small group. In addition, literature solutions are verified on relatively small databases. The goal of this research is to develop a novel algorithm for fully automated kidney segmentation. This approach is designed for large database analysis including both physiological and pathological cases. This study presents a 3D marker-controlled watershed transform developed and employed for fully automated CT kidney segmentation. The original and the most complex step in the current proposition is an automatic generation of 3D marker images. The final kidney segmentation step is an analysis of the labelled image obtained from marker-controlled watershed transform. It consists of morphological operations and shape analysis. The implementation is conducted in a MATLAB environment, Version 2017a, using i.a. Image Processing Toolbox. 170 clinical CT abdominal studies have been subjected to the analysis. The dataset includes normal as well as various pathological cases (agenesis, renal cysts, tumors, renal cell carcinoma, kidney cirrhosis, partial or radical nephrectomy, hematoma and nephrolithiasis). Manual and semi-automated delineations have been used as a gold standard. Wieclawek Among 67 delineated medical cases, 62 cases are 'Very good', whereas only 5 are 'Good' according to Cohen's Kappa interpretation. The segmentation results show that mean values of Sensitivity, Specificity, Dice, Jaccard, Cohen's Kappa and Accuracy are 90.29, 99.96, 91.68, 85.04, 91.62 and 99.89% respectively. All 170 medical cases (with and without outlines) have been classified by three independent medical experts as 'Very good' in 143

  18. Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT.

    PubMed

    Leng, Shuai; Yu, Lifeng; Fletcher, Joel G; McCollough, Cynthia H

    2015-08-01

    To determine the iodine contrast-to-noise ratio (CNR) for abdominal computed tomography (CT) when using energy domain noise reduction and virtual monoenergetic dual-energy (DE) CT images and to compare the CNR to that attained with single-energy CT at 80, 100, 120, and 140 kV. This HIPAA-compliant study was approved by the institutional review board with waiver of informed consent. A syringe filled with diluted iodine contrast material was placed into 30-, 35-, and 45-cm-wide water phantoms and scanned with a dual-source CT scanner in both DE and single-energy modes with matched scanner output. Virtual monoenergetic images were generated, with energies ranging from 40 to 110 keV in 10-keV steps. A previously developed energy domain noise reduction algorithm was applied to reduce image noise by exploiting information redundancies in the energy domain. Image noise and iodine CNR were calculated. To show the potential clinical benefit of this technique, it was retrospectively applied to a clinical DE CT study of the liver in a 59-year-old male patient by using conventional and iterative reconstruction techniques. Image noise and CNR were compared for virtual monoenergetic images with and without energy domain noise reduction at each virtual monoenergetic energy (in kiloelectron volts) and phantom size by using a paired t test. CNR of virtual monoenergetic images was also compared with that of single-energy images acquired with 80, 100, 120, and 140 kV. Noise reduction of up to 59% (28.7 of 65.7) was achieved for DE virtual monoenergetic images by using an energy domain noise reduction technique. For the commercial virtual monoenergetic images, the maximum iodine CNR was achieved at 70 keV and was 18.6, 16.6, and 10.8 for the 30-, 35-, and 45-cm phantoms. After energy domain noise reduction, maximum iodine CNR was achieved at 40 keV and increased to 30.6, 25.4, and 16.5. These CNRs represented improvement of up to 64% (12.0 of 18.6) with the energy domain noise

  19. Quality of pediatric abdominal CT scans performed at a dedicated children's hospital and its referring institutions: a multifactorial evaluation.

    PubMed

    Snow, Aisling; Milliren, Carly E; Graham, Dionne A; Callahan, Michael J; MacDougall, Robert D; Robertson, Richard L; Taylor, George A

    2017-04-01

    Pediatric patients requiring transfer to a dedicated children's hospital from an outside institution may undergo CT imaging as part of their evaluation. Whether this imaging is performed prior to or after transfer has been shown to impact the radiation dose imparted to the patient. Other quality variables could also be affected by the pediatric experience and expertise of the scanning institution. To identify differences in quality between abdominal CT scans and reports performed at a dedicated children's hospital, and those performed at referring institutions. Fifty consecutive pediatric abdominal CT scans performed at outside institutions were matched (for age, gender and indication) with 50 CT scans performed at a dedicated freestanding children's hospital. We analyzed the scans for technical parameters, report findings, correlation with final clinical diagnosis, and clinical utility. Technical evaluation included use of intravenous and oral contrast agents, anatomical coverage, number of scan phases and size-specific dose estimate (SSDE) for each scan. Outside institution scans were re-reported when the child was admitted to the children's hospital; they were also re-interpreted for this study by children's hospital radiologists who were provided with only the referral information given in the outside institution's report. Anonymized original outside institutional reports and children's hospital admission re-reports were analyzed by two emergency medicine physicians for ease of understanding, degree to which the clinical question was answered, and level of confidence in the report. Mean SSDE was lower (8.68) for children's hospital scans, as compared to outside institution scans (13.29, P = 0.03). Concordance with final clinical diagnosis was significantly lower for original outside institution reports (38/48, 79%) than for both the admission and study children's hospital reports (48/50, 96%; P = 0.005). Children's hospital admission reports were rated

  20. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique

    PubMed Central

    Cho, Jinhan; Oh, Jongyeong; Kim, Dongwon; Cho, Junghyun; Kim, Sanghyun; Lee, Sangyun; Lee, Jihyun

    2015-01-01

    Objective: To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. Methods: 27 consecutive patients (mean body mass index: 23.55 kg m−2 underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. Results: At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19–49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. Conclusion: Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. Advances in knowledge: This study represents the first

  1. SU-F-18C-12: On the Relationship of the Weighted Dose to the Surface Dose In Abdominal CT - Patient Size Dependency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Y; Scott, A; Allahverdian, J

    2014-06-15

    Purpose: It is possible to measure the patient surface dose non-invasively using radiolucent dosimeters. However, the patient size specific weighted dose remains unknown. We attempted to study the weighted dose to surface dose relationship as the patient size varies in abdominal CT. Methods: Seven abdomen phantoms (CIRS TE series) simulating patients from an infant to a large adult were used. Size specific doses were measured with a 100 mm CT chamber under axial scans using a Siemens Sensation 64 (mCT) and a GE 750 HD. The scanner settings were 120 kVp, 200 mAs with fully opened collimations. Additional kVps (80,more » 100, 140) were added depending on the phantom sizes. The ratios (r) of the weighted CT dose (Dw) to the surface dose (Ds) were related to the phantom size (L) defined as the diameter resulting the equivalent cross-sectional area. Results: The Dw versus Ds ratio (r) was fitted to a linear relationship: r = 1.083 − 0.007L (R square = 0.995), and r = 1.064 − 0.007L (R square = 0.953), for Siemens Sensation 64 and GE 750 HD, respectively. The relationship appears to be independent of the scanner specifics. Conclusion: The surface dose to the weighted dose ratio decreases linearly as the patient size increases. The result is independent of the scanner specifics. The result can be used to obtain in vivo CT dosimetry in abdominal CT.« less

  2. Significance of computed tomography finding of intra-abdominal free fluid without solid organ injury after blunt abdominal trauma: time for laparotomy on demand.

    PubMed

    Mahmood, Ismail; Tawfek, Zainab; Abdelrahman, Yassir; Siddiuqqi, Tariq; Abdelrahman, Husham; El-Menyar, Ayman; Al-Hassani, Ammar; Tuma, Mazin; Peralta, Ruben; Zarour, Ahmad; Yakhlef, Sawsan; Hamzawi, Hazim; Al-Thani, Hassan; Latifi, Rifat

    2014-06-01

    Optimal management of patients with intra-abdominal free fluid found on computed tomography (CT) scan without solid organ injury remains controversial. The purpose of this study was to determine the significance of CT scan findings of free fluid in the management of blunt abdominal trauma patients who otherwise have no indications for laparotomy. During the 3-year study period, all patients presenting with blunt abdominal trauma who underwent abdominal CT examination were retrospectively reviewed. All hemodynamically stable patients who presented with abdominal free fluid without solid organ injury on CT scan were analyzed for radiological interpretation, clinical management, operative findings, and outcome. A total of 122 patients were included in the study, 91 % of whom were males. The mean age of the patients was 33 ± 12 years. A total of 34 patients underwent exploratory laparotomy, 31 of whom had therapeutic interventions. Small bowel injuries were found in 12 patients, large bowel injuries in ten, and mesenteric injuries in seven patients. One patient had combined small and large bowel injury, and one had traumatic gangrenous appendix. In the remaining three patients, laparotomy was non-therapeutic. A total of 36 patients had associated pelvic fractures and 33 had multiple lumbar transverse process fractures. Detection of intra-peritoneal fluid by CT scan is inaccurate for prediction of bowel injury or need for surgery. However, the correlation between CT scan findings and clinical course is important for optimal diagnosis of bowel and mesenteric injuries.

  3. Abdominal multi-organ segmentation from CT images using conditional shape–location and unsupervised intensity priors

    PubMed Central

    Linguraru, Marius George; Hori, Masatoshi; Summers, Ronald M; Tomiyama, Noriyuki

    2015-01-01

    This paper addresses the automated segmentation of multiple organs in upper abdominal computed tomography (CT) data. The aim of our study is to develop methods to effectively construct the conditional priors and use their prediction power for more accurate segmentation as well as easy adaptation to various imaging conditions in CT images, as observed in clinical practice. We propose a general framework of multi-organ segmentation which effectively incorporates interrelations among multiple organs and easily adapts to various imaging conditions without the need for supervised intensity information. The features of the framework are as follows: (1) A method for modeling conditional shape and location (shape–location) priors, which we call prediction-based priors, is developed to derive accurate priors specific to each subject, which enables the estimation of intensity priors without the need for supervised intensity information. (2) Organ correlation graph is introduced, which defines how the conditional priors are constructed and segmentation processes of multiple organs are executed. In our framework, predictor organs, whose segmentation is sufficiently accurate by using conventional single-organ segmentation methods, are pre-segmented, and the remaining organs are hierarchically segmented using conditional shape–location priors. The proposed framework was evaluated through the segmentation of eight abdominal organs (liver, spleen, left and right kidneys, pancreas, gallbladder, aorta, and inferior vena cava) from 134 CT data from 86 patients obtained under six imaging conditions at two hospitals. The experimental results show the effectiveness of the proposed prediction-based priors and the applicability to various imaging conditions without the need for supervised intensity information. Average Dice coefficients for the liver, spleen, and kidneys were more than 92%, and were around 73% and 67% for the pancreas and gallbladder, respectively. PMID:26277022

  4. Abdominal multi-organ segmentation from CT images using conditional shape-location and unsupervised intensity priors.

    PubMed

    Okada, Toshiyuki; Linguraru, Marius George; Hori, Masatoshi; Summers, Ronald M; Tomiyama, Noriyuki; Sato, Yoshinobu

    2015-12-01

    This paper addresses the automated segmentation of multiple organs in upper abdominal computed tomography (CT) data. The aim of our study is to develop methods to effectively construct the conditional priors and use their prediction power for more accurate segmentation as well as easy adaptation to various imaging conditions in CT images, as observed in clinical practice. We propose a general framework of multi-organ segmentation which effectively incorporates interrelations among multiple organs and easily adapts to various imaging conditions without the need for supervised intensity information. The features of the framework are as follows: (1) A method for modeling conditional shape and location (shape-location) priors, which we call prediction-based priors, is developed to derive accurate priors specific to each subject, which enables the estimation of intensity priors without the need for supervised intensity information. (2) Organ correlation graph is introduced, which defines how the conditional priors are constructed and segmentation processes of multiple organs are executed. In our framework, predictor organs, whose segmentation is sufficiently accurate by using conventional single-organ segmentation methods, are pre-segmented, and the remaining organs are hierarchically segmented using conditional shape-location priors. The proposed framework was evaluated through the segmentation of eight abdominal organs (liver, spleen, left and right kidneys, pancreas, gallbladder, aorta, and inferior vena cava) from 134 CT data from 86 patients obtained under six imaging conditions at two hospitals. The experimental results show the effectiveness of the proposed prediction-based priors and the applicability to various imaging conditions without the need for supervised intensity information. Average Dice coefficients for the liver, spleen, and kidneys were more than 92%, and were around 73% and 67% for the pancreas and gallbladder, respectively. Copyright © 2015

  5. Estimating patient dose from CT exams that use automatic exposure control: Development and validation of methods to accurately estimate tube current values.

    PubMed

    McMillan, Kyle; Bostani, Maryam; Cagnon, Christopher H; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H; McNitt-Gray, Michael F

    2017-08-01

    The vast majority of body CT exams are performed with automatic exposure control (AEC), which adapts the mean tube current to the patient size and modulates the tube current either angularly, longitudinally or both. However, most radiation dose estimation tools are based on fixed tube current scans. Accurate estimates of patient dose from AEC scans require knowledge of the tube current values, which is usually unavailable. The purpose of this work was to develop and validate methods to accurately estimate the tube current values prescribed by one manufacturer's AEC system to enable accurate estimates of patient dose. Methods were developed that took into account available patient attenuation information, user selected image quality reference parameters and x-ray system limits to estimate tube current values for patient scans. Methods consistent with AAPM Report 220 were developed that used patient attenuation data that were: (a) supplied by the manufacturer in the CT localizer radiograph and (b) based on a simulated CT localizer radiograph derived from image data. For comparison, actual tube current values were extracted from the projection data of each patient. Validation of each approach was based on data collected from 40 pediatric and adult patients who received clinically indicated chest (n = 20) and abdomen/pelvis (n = 20) scans on a 64 slice multidetector row CT (Sensation 64, Siemens Healthcare, Forchheim, Germany). For each patient dataset, the following were collected with Institutional Review Board (IRB) approval: (a) projection data containing actual tube current values at each projection view, (b) CT localizer radiograph (topogram) and (c) reconstructed image data. Tube current values were estimated based on the actual topogram (actual-topo) as well as the simulated topogram based on image data (sim-topo). Each of these was compared to the actual tube current values from the patient scan. In addition, to assess the accuracy of each method in estimating

  6. TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Chan, F; Newman, B

    2014-06-15

    Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less

  7. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    PubMed

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  8. SU-E-I-36: A KWIC and Dirty Look at Dose Savings and Perfusion Metrics in Simulated CT Neuro Perfusion Exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, J; Martin, T; Young, S

    Purpose: CT neuro perfusion scans are one of the highest dose exams. Methods to reduce dose include decreasing the number of projections acquired per gantry rotation, however conventional reconstruction of such scans leads to sampling artifacts. In this study we investigated a projection view-sharing reconstruction algorithm used in dynamic MRI – “K-space Weighted Image Contrast” (KWIC) – applied to simulated perfusion exams and evaluated dose savings and impacts on perfusion metrics. Methods: A FORBILD head phantom containing simulated time-varying objects was developed and a set of parallel-beam CT projection data was created. The simulated scans were 60 seconds long, 1152more » projections per turn, with a rotation time of one second. No noise was simulated. 5mm, 10mm, and 50mm objects were modeled in the brain. A baseline, “full dose” simulation used all projections and reduced dose cases were simulated by downsampling the number of projections per turn from 1152 to 576 (50% dose), 288 (25% dose), and 144 (12.5% dose). KWIC was further evaluated at 72 projections per rotation (6.25%). One image per second was reconstructed using filtered backprojection (FBP) and KWIC. KWIC reconstructions utilized view cores of 36, 72, 144, and 288 views and 16, 8, 4, and 2 subapertures respectively. From the reconstructed images, time-to-peak (TTP), cerebral blood flow (CBF) and the FWHM of the perfusion curve were calculated and compared against reference values from the full-dose FBP data. Results: TTP, CBF, and the FWHM were unaffected by dose reduction (to 12.5%) and reconstruction method, however image quality was improved when using KWIC. Conclusion: This pilot study suggests that KWIC preserves image quality and perfusion metrics when under-sampling projections and that the unique contrast weighting of KWIC could provided substantial dose-savings for perfusion CT scans. Evaluation of KWIC in clinical CT data will be performed in the near future. R01 EB

  9. Predicting hollow viscus injury in blunt abdominal trauma with computed tomography.

    PubMed

    Bhagvan, Savitha; Turai, Matthew; Holden, Andrew; Ng, Alexander; Civil, Ian

    2013-01-01

    Evaluation of blunt abdominal trauma is controversial. Computed tomography (CT) of the abdomen is commonly used but has limitations, especially in excluding hollow viscus injury in the presence of solid organ injury. To determine whether CT reports alone could be used to direct operative treatment in abdominal trauma, this study was undertaken. The trauma database at Auckland City Hospital was accessed for patients who had abdominal CT and subsequent laparotomy during a five-year period. The CT scans were reevaluated by a consultant radiologist who was blinded to operative findings. The CT findings were correlated with the operative findings. Between January 2002 and December 2007, 1,250 patients were evaluated for blunt abdominal injury with CT. A subset of 78 patients underwent laparotomy, and this formed the study group. The sensitivity and specificity of CT scan in predicting hollow viscus injury was 55.33 and 92.06 % respectively. The positive and negative predictive values were 61.53 and 89.23 % respectively. Presence of free fluid in CT scan was sensitive in diagnosing hollow viscus injury (90 %). Specific findings for hollow viscus injuries on CT scan were free intraperitoneal air (93 %), retroperitoneal air (100 %), oral contrast extravasation (100 %), bowel wall defect (98 %), patchy bowel enhancement (97 %), and mesenteric abnormality (94 %). CT alone cannot be used as a screening tool for hollow viscus injury. The decision to operate in hollow viscus injury has to be based on mechanism of injury and clinical findings together with radiological evidence.

  10. Paediatric blunt abdominal trauma - are we doing too many computed tomography scans?

    PubMed

    Arnold, M; Moore, S W

    2013-02-14

    Blunt abdominal trauma in childhood contributes significantly to both morbidity and mortality. Selective non-operative management of blunt abdominal trauma in children depends on both diagnostic and clinical factors. Computed tomography (CT) scanning is widely used to facilitate better management. Increased availability of CT may, however, result in its overuse in the management of blunt abdominal trauma in children, which carries significant radiation exposure risks. To evaluate the use and value of CT scanning in the overall management and outcome of blunt abdominal trauma in children in the Tygerberg Academic Hospital trauma unit, Parow, Cape Town, South Africa, before and after improved access to CT as a result of installation of a new rapid CT scanner in the trauma management area (previously the scanner had been 4 floors away). Patients aged 0 - 13 years who were referred with blunt abdominal trauma due to vehicle-related accidents before the introduction of the new CT scanner (group 1, n=66, November 2003 - March 2009) were compared with those seen in the 1-year period after the scanner was installed (group 2, n=37, April 2009 - April 2010). Details of clinical presentation, imaging results and their influence on management were retrospectively reviewed. A follow-up group was evaluated after stricter criteria for abdominal CT scanning (viz. prior evaluation by paediatric surgical personnel) were introduced (group 3, n=14, November 2011 - May 2012) to evaluate the impact of this clinical screening on the rate of negative scans. There were 66 patients in group 1 and 37 in group 2. An apparent increase in CT use with increased availability was accompanied by a marked increase in negative CT scans (38.9% compared with 6.2%; p<0.006). Despite a slightly higher prevalence of associated injuries in group 2, as well as a slightly longer length of hospital stay, there was a similar prevalence of intra-abdominal injuries detected in positive scans in the two groups

  11. Extra-abdominal lumbar abscesses caused by retroperitoneal gastrointestinal perforations through the lumbar triangle of Petit: report of two cases diagnosed by CT.

    PubMed

    Coulier, Bruno; Gogoase, Monica; Ramboux, Adrien; Pierard, Frederic

    2012-12-01

    Extra-abdominal abscesses of gastrointestinal origin developing within the lumbar subcutaneous tissues are extremely rare. We report two cases of retroperitoneal bowel perforation presenting spontaneously at admission with a lumbar abscess trespassing the lumbar triangle of Petit, a classical "locus of minus resistencia" of the posterior abdominal wall. The first case was caused by perforation of a retrocecal appendicitis--being concomitantly responsible of a necrotizing fasciitis of the thigh--and in the second case perforation was caused by left colonic diverticulitis. In both cases, the full diagnosis was made with abdominal CT. The patients were threatened by a two-step surgical approach comprising a direct posterior percutaneous drainage of the abscess followed by classical laparotomy.

  12. Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bjarnason, Thorarin

    Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used inmore » this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.« less

  13. Abdominal and Pelvic CT

    MedlinePlus Videos and Cool Tools

    ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  14. Energy Limits in Second Generation High-pitch Dual Source CT - Comparison in an Upper Abdominal Phantom

    PubMed Central

    Beeres, Martin; Bauer, Ralf W; Kerl, Josef M; Vogl, Thomas J; Lee, Clara

    2015-01-01

    Objectives: The aim of our study was to find out how much energy is applicable in second-generation dual source high-pitch computed tomography (CT) in imaging of the abdomen. Materials and Methods: We examined an upper abdominal phantom using a Somatom Definition Flash CT-Scanner (Siemens, Forchheim, Germany). The study protocol consisted of a scan-series at 100 kV and 120 kV. In each scan series we started with a pitch of 3.2 and reduced it in steps of 0.2, until a pitch of 1.6 was reached. The current was adjusted to the maximum the scanner could achieve. Energy values, image noise, image quality, and radiation exposure were evaluated. Results: For a pitch of 3.2 the maximum applicable current was 142 mAs at 120 kV and in 100 kV the maximum applicable current was 114 mAs. For conventional abdominal imaging, current levels of 200 to 260 mAs are generally used. To achieve similar current levels, we had to decrease the pitch to 1.8 at 100 kV — at this pitch we could perform our imaging at 204 mAs. At a pitch of 2.2 in 120 kV we could apply a current of 206 mAs. Conclusion: We conclude our study by stating that if there is a need for a higher current, we have to reduce the pitch. In a high-pitch dual source CT, we always have to remember where our main focus is, so we can adjust the pitch to the energy we need in the area of the body that has to be imaged, to find answers to the clinical question being raised. PMID:25806137

  15. A hybrid 3D region growing and 4D curvature analysis-based automatic abdominal blood vessel segmentation through contrast enhanced CT

    NASA Astrophysics Data System (ADS)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Shimada, Mitsuo; Iinuma, Gen

    2017-03-01

    In abdominal disease diagnosis and various abdominal surgeries planning, segmentation of abdominal blood vessel (ABVs) is a very imperative task. Automatic segmentation enables fast and accurate processing of ABVs. We proposed a fully automatic approach for segmenting ABVs through contrast enhanced CT images by a hybrid of 3D region growing and 4D curvature analysis. The proposed method comprises three stages. First, candidates of bone, kidneys, ABVs and heart are segmented by an auto-adapted threshold. Second, bone is auto-segmented and classified into spine, ribs and pelvis. Third, ABVs are automatically segmented in two sub-steps: (1) kidneys and abdominal part of the heart are segmented, (2) ABVs are segmented by a hybrid approach that integrates a 3D region growing and 4D curvature analysis. Results are compared with two conventional methods. Results show that the proposed method is very promising in segmenting and classifying bone, segmenting whole ABVs and may have potential utility in clinical use.

  16. A reappraisal of adult thoracic and abdominal surface anatomy via CT scan in Chinese population.

    PubMed

    Shen, Xin-Hua; Su, Bai-Yan; Liu, Jing-Juan; Zhang, Gu-Muyang; Xue, Hua-Dan; Jin, Zheng-Yu; Mirjalili, S Ali; Ma, Chao

    2016-03-01

    Accurate surface anatomy is essential for safe clinical practice. There are numerous inconsistencies in clinically important surface markings among and within contemporary anatomical reference texts. The aim of this study was to investigate key thoracic and abdominal surface anatomy landmarks in living Chinese adults using computed tomography (CT). A total of 100 thoracic and 100 abdominal CT scans were examined. Our results indicated that the following key surface landmarks differed from current commonly-accepted descriptions: the positions of the tracheal bifurcation, azygos vein termination, and pulmonary trunk bifurcation (all below the plane of the sternal angle at vertebral level T5-T6 in most individuals); the superior vena cava formation and junction with the right atrium (most often behind the 1st and 4th intercostal spaces, respectively); and the level at which the inferior vena cava and esophagus traverse the diaphragm (T10 and T11, respectively). The renal arteries were most commonly at L1; the midpoint of the renal hila was most frequently at L2; the 11th rib was posterior to the left kidney in only 29% of scans; and the spleen was most frequently located between the 10th and 12th ribs. A number of significant sex- and age-related differences were noted. The Chinese population was also compared with western populations on the basis of published reports. Reappraisal of surface anatomy using modern imaging tools in vivo will provide both quantitative and qualitative evidence to facilitate the clinical application of these key surface landmarks. © 2015 Wiley Periodicals, Inc.

  17. Segmenting the thoracic, abdominal and pelvic musculature on CT scans combining atlas-based model and active contour model

    NASA Astrophysics Data System (ADS)

    Zhang, Weidong; Liu, Jiamin; Yao, Jianhua; Summers, Ronald M.

    2013-03-01

    Segmentation of the musculature is very important for accurate organ segmentation, analysis of body composition, and localization of tumors in the muscle. In research fields of computer assisted surgery and computer-aided diagnosis (CAD), muscle segmentation in CT images is a necessary pre-processing step. This task is particularly challenging due to the large variability in muscle structure and the overlap in intensity between muscle and internal organs. This problem has not been solved completely, especially for all of thoracic, abdominal and pelvic regions. We propose an automated system to segment the musculature on CT scans. The method combines an atlas-based model, an active contour model and prior segmentation of fat and bones. First, body contour, fat and bones are segmented using existing methods. Second, atlas-based models are pre-defined using anatomic knowledge at multiple key positions in the body to handle the large variability in muscle shape. Third, the atlas model is refined using active contour models (ACM) that are constrained using the pre-segmented bone and fat. Before refining using ACM, the initialized atlas model of next slice is updated using previous atlas. The muscle is segmented using threshold and smoothed in 3D volume space. Thoracic, abdominal and pelvic CT scans were used to evaluate our method, and five key position slices for each case were selected and manually labeled as the reference. Compared with the reference ground truth, the overlap ratio of true positives is 91.1%+/-3.5%, and that of false positives is 5.5%+/-4.2%.

  18. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    PubMed

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.

  19. Multi-organ segmentation from multi-phase abdominal CT via 4D graphs using enhancement, shape and location optimization.

    PubMed

    Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M

    2010-01-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.

  20. Isolated free intra-abdominal fluid on CT in blunt trauma: The continued diagnostic dilemma.

    PubMed

    Kong, Victor Y; Jeetoo, Damon; Naidoo, Leah C; Oosthuizen, George V; Clarke, Damian L

    2015-01-01

    The clinical significance of isolated free fluid (FF) without solid organ injury on computed to- mography (CT) continues to pose significant dilemma in the management of patients with blunt abdominal trauma (BAT). We reviewed the incidence of FF and the clinical outcome amongst patients with blunt abdominal trauma in a metropolitan trauma service in South Africa. We performed a retrospective study of 121 consecutive CT scans over a period of 12 months to determine the incidence of isolated FF and the clinical outcome of patients managed in a large metropolitan trauma service. Of the 121 CTs, FF was identified in 36 patients (30%). Seven patients (6%) had isolated FF. Of the 29 patients who had free fluid and associated organ injuries, 33 organ injuries were identified. 86% (25/ 29) of all 29 patients had a single organ injury and 14% had multiple organ injuries. There were 26 solid organ injuries and 7 hollow organ injuries. The 33 organs injured were: spleen, 12; liver, 8; kidney, 5; pancreas, 2; small bowel, 4; duodenum, 1. Six (21%) patients required operative management for small bowel perforations in 4 cases and pancreatic tail injury in 2 cases. All 7 patients with isolated FF were initially observed, and 3 (43%) were eventually subjected to operative intervention. They were found to have an intra-peritoneal bladder rupture in 1 case, a non-expanding zone 3 haematoma in 1 case, and a negative laparotomy in 1 case. Four (57%) patients were successfully managed without surgical interventions. Isolated FF is uncommon and the clinical significance remains unclear. Provided that reli- able serial physical examination can be performed by experienced surgeons, an initial non-operative approach should be considered.

  1. Abdominal fat distribution on computed tomography predicts ureteric calculus fragmentation by shock wave lithotripsy.

    PubMed

    Juan, Hsu-Cheng; Lin, Hung-Yu; Chou, Yii-Her; Yang, Yi-Hsin; Shih, Paul Ming-Chen; Chuang, Shu-Mien; Shen, Jung-Tsung; Juan, Yung-Shun

    2012-08-01

    To assess the effects of abdominal fat on shock wave lithotripsy (SWL). We used pre-SWL unenhanced computed tomography (CT) to evaluate the impact of abdominal fat distribution and calculus characteristics on the outcome of SWL. One hundred and eighty-five patients with a solitary ureteric calculus treated with SWL were retrospectively reviewed. Each patient underwent unenhanced CT within 1 month before SWL treatment. Treatment outcomes were evaluated 1 month later. Unenhanced CT parameters, including calculus surface area, Hounsfield unit (HU) density, abdominal fat area and skin to calculus distance (SSD) were analysed. One hundred and twenty-eight of the 185 patients were found to be calculus-free following treatment. HU density, total fat area, visceral fat area and SSD were identified as significant variables on multivariate logistic regression analysis. The receiver-operating characteristic analyses showed that total fat area, para/perirenal fat area and visceral fat area were sensitive predictors of SWL outcomes. This study revealed that higher quantities of abdominal fat, especially visceral fat, are associated with a lower calculus-free rate following SWL treatment. Unenhanced CT is a convenient technique for diagnosing the presence of a calculus, assessing the intra-abdominal fat distribution and thereby helping to predict the outcome of SWL. • Unenhanced CT is now widely used to assess ureteric calculi. • The same CT protocol can provide measurements of abdominal fat distribution. • Ureteric calculi are usually treated by shock wave lithotripsy (SWL). • Greater intra-abdominal fat stores are generally associated with poorer SWL results.

  2. Multi-atlas segmentation for abdominal organs with Gaussian mixture models

    NASA Astrophysics Data System (ADS)

    Burke, Ryan P.; Xu, Zhoubing; Lee, Christopher P.; Baucom, Rebeccah B.; Poulose, Benjamin K.; Abramson, Richard G.; Landman, Bennett A.

    2015-03-01

    Abdominal organ segmentation with clinically acquired computed tomography (CT) is drawing increasing interest in the medical imaging community. Gaussian mixture models (GMM) have been extensively used through medical segmentation, most notably in the brain for cerebrospinal fluid / gray matter / white matter differentiation. Because abdominal CT exhibit strong localized intensity characteristics, GMM have recently been incorporated in multi-stage abdominal segmentation algorithms. In the context of variable abdominal anatomy and rich algorithms, it is difficult to assess the marginal contribution of GMM. Herein, we characterize the efficacy of an a posteriori framework that integrates GMM of organ-wise intensity likelihood with spatial priors from multiple target-specific registered labels. In our study, we first manually labeled 100 CT images. Then, we assigned 40 images to use as training data for constructing target-specific spatial priors and intensity likelihoods. The remaining 60 images were evaluated as test targets for segmenting 12 abdominal organs. The overlap between the true and the automatic segmentations was measured by Dice similarity coefficient (DSC). A median improvement of 145% was achieved by integrating the GMM intensity likelihood against the specific spatial prior. The proposed framework opens the opportunities for abdominal organ segmentation by efficiently using both the spatial and appearance information from the atlases, and creates a benchmark for large-scale automatic abdominal segmentation.

  3. Splenic trauma during abdominal wall liposuction: a case report

    PubMed Central

    Harnett, Paul; Koak, Yashwant; Baker, Daryl

    2008-01-01

    Summary A 35-year-old woman collapsed 18 hours after undergoing abdominal wall liposuction. Abdominal CT scan revealed a punctured spleen. She underwent an emergency splenectomy and made an uneventful recovery. PMID:18387911

  4. Point Organ Radiation Dose in Abdominal CT: Effect of Patient Off-Centering in an Experimental Human Cadaver Study.

    PubMed

    Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K

    2017-08-01

    To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p < 0.01). Variation in point doses between fixed-mA and AEC protocols were statistically significant across all organs at all Table positions (p < 0.001). There was up to 5-6% decrease in point doses with upward off-centering and in downward off-centering. There were statistical significant differences in point doses from dosimeters and dose-tracking software (mean difference for internal organs, 5-36% for fixed-mA & 7-48% for AEC protocols; p < 0.001; mean difference for surface organs, >92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the

  5. Development of automated extraction method of biliary tract from abdominal CT volumes based on local intensity structure analysis

    NASA Astrophysics Data System (ADS)

    Koga, Kusuto; Hayashi, Yuichiro; Hirose, Tomoaki; Oda, Masahiro; Kitasaka, Takayuki; Igami, Tsuyoshi; Nagino, Masato; Mori, Kensaku

    2014-03-01

    In this paper, we propose an automated biliary tract extraction method from abdominal CT volumes. The biliary tract is the path by which bile is transported from liver to the duodenum. No extraction method have been reported for the automated extraction of the biliary tract from common contrast CT volumes. Our method consists of three steps including: (1) extraction of extrahepatic bile duct (EHBD) candidate regions, (2) extraction of intrahepatic bile duct (IHBD) candidate regions, and (3) combination of these candidate regions. The IHBD has linear structures and intensities of the IHBD are low in CT volumes. We use a dark linear structure enhancement (DLSE) filter based on a local intensity structure analysis method using the eigenvalues of the Hessian matrix for the IHBD candidate region extraction. The EHBD region is extracted using a thresholding process and a connected component analysis. In the combination process, we connect the IHBD candidate regions to each EHBD candidate region and select a bile duct region from the connected candidate regions. We applied the proposed method to 22 cases of CT volumes. An average Dice coefficient of extraction result was 66.7%.

  6. Abdominal Trauma Revisited.

    PubMed

    Feliciano, David V

    2017-11-01

    Although abdominal trauma has been described since antiquity, formal laparotomies for trauma were not performed until the 1800s. Even with the introduction of general anesthesia in the United States during the years 1842 to 1846, laparotomies for abdominal trauma were not performed during the Civil War. The first laparotomy for an abdominal gunshot wound in the United States was finally performed in New York City in 1884. An aggressive operative approach to all forms of abdominal trauma till the establishment of formal trauma centers (where data were analyzed) resulted in extraordinarily high rates of nontherapeutic laparotomies from the 1880s to the 1960s. More selective operative approaches to patients with abdominal stab wounds (1960s), blunt trauma (1970s), and gunshot wounds (1990s) were then developed. Current adjuncts to the diagnosis of abdominal trauma when serial physical examinations are unreliable include the following: 1) diagnostic peritoneal tap/lavage, 2) surgeon-performed ultrasound examination; 3) contrast-enhanced CT of the abdomen and pelvis; and 4) diagnostic laparoscopy. Operative techniques for injuries to the liver, spleen, duodenum, and pancreas have been refined considerably since World War II. These need to be emphasized repeatedly in an era when fewer patients undergo laparotomy for abdominal trauma. Finally, abdominal trauma damage control is a valuable operative approach in patients with physiologic exhaustion and multiple injuries.

  7. Computed tomography use among children presenting to emergency departments with abdominal pain.

    PubMed

    Fahimi, Jahan; Herring, Andrew; Harries, Aaron; Gonzales, Ralph; Alter, Harrison

    2012-11-01

    To evaluate trends in and factors associated with computed tomography (CT) use among children presenting to the emergency department (ED) with abdominal pain. This study was a cross-sectional, secondary analysis of the National Hospital Ambulatory Medical Care Survey data from 1998 to 2008. We identified ED patients aged <19 years with abdominal pain and collected patient demographic and hospital characteristics, and outcomes related to imaging, hospital admission, and diagnosis of appendicitis. Trend analysis was performed over the study period for the outcomes of interest, and a multivariate regression model was used to identify factors associated with CT use. Of all pediatric ED visits, 6.0% were for abdominal pain. We noted a rise in the proportion of these patients with CT use, from 0.9% in 1998 to 15.4% in 2008 (P < .001), with no change in ultrasound/radiograph use, diagnosis of appendicitis, or hospital admission. Older and male patients were more likely to have a CT scan, whereas black children were one-half as likely to undergo a CT scan compared with white children (odds ratio: 0.50 [95% confidence interval: 0.31-0.81]). Admitted children had much higher odds of undergoing a CT scan (odds ratio: 4.11 [95% confidence interval: 2.66-6.35]). There was a plateau in CT use in 2006 to 2008. There was a dramatic increase in the utilization of CT imaging in the ED evaluation of pediatric patients with abdominal pain. Some groups of children may have a differential likelihood of receiving CT scans.

  8. Examining Exam Reviews: A Comparison of Exam Scores and Attitudes

    ERIC Educational Resources Information Center

    Hackathorn, Jana; Cornell, Kathryn; Garczynski, Amy M.; Solomon, Erin D.; Blankmeyer, Katheryn E.; Tennial, Rachel E.

    2012-01-01

    Instructors commonly use exam reviews to help students prepare for exams and to increase student success. The current study compared the effects of traditional, trivia, and practice test-based exam reviews on actual exam scores, as well as students' attitudes toward each review. Findings suggested that students' exam scores were significantly…

  9. The feasibility of a regional CTDI{sub vol} to estimate organ dose from tube current modulated CT exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khatonabadi, Maryam; Kim, Hyun J.; Lu, Peiyun

    Purpose: In AAPM Task Group 204, the size-specific dose estimate (SSDE) was developed by providing size adjustment factors which are applied to the Computed Tomography (CT) standardized dose metric, CTDI{sub vol}. However, that work focused on fixed tube current scans and did not specifically address tube current modulation (TCM) scans, which are currently the majority of clinical scans performed. The purpose of this study was to extend the SSDE concept to account for TCM by investigating the feasibility of using anatomic and organ specific regions of scanner output to improve accuracy of dose estimates. Methods: Thirty-nine adult abdomen/pelvis and 32more » chest scans from clinically indicated CT exams acquired on a multidetector CT using TCM were obtained with Institutional Review Board approval for generating voxelized models. Along with image data, raw projection data were obtained to extract TCM functions for use in Monte Carlo simulations. Patient size was calculated using the effective diameter described in TG 204. In addition, the scanner-reported CTDI{sub vol} (CTDI{sub vol,global}) was obtained for each patient, which is based on the average tube current across the entire scan. For the abdomen/pelvis scans, liver, spleen, and kidneys were manually segmented from the patient datasets; for the chest scans, lungs and for female models only, glandular breast tissue were segmented. For each patient organ doses were estimated using Monte Carlo Methods. To investigate the utility of regional measures of scanner output, regional and organ anatomic boundaries were identified from image data and used to calculate regional and organ-specific average tube current values. From these regional and organ-specific averages, CTDI{sub vol} values, referred to as regional and organ-specific CTDI{sub vol}, were calculated for each patient. Using an approach similar to TG 204, all CTDI{sub vol} values were used to normalize simulated organ doses; and the ability of each

  10. 4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Yong, E-mail: hu.yong@zs-hospital.sh.cn; Zhou,

    Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area betweenmore » the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z

  11. SU-E-I-27: Estimating KERMA Area Product for CT Localizer Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogden, K; Greene-Donnelly, K; Bennett, R

    2015-06-15

    Purpose: To estimate the free-in-air KERMA-Area Product (KAP) incident on patients due to CT localizer scans for common CT exams. Methods: In-plane beam intensity profiles were measured in localizer acquisition mode using OSLs for a 64 slice MDCT scanner (Lightspeed VCT, GE Medical Systems, Waukesha WI). The z-axis beam width was measured as a function of distance from isocenter. The beam profile and width were used to calculate a weighted average air KERMA per unit mAs as a function of intercepted x-axis beam width for objects symmetric about the localizer centerline.Patient areas were measured using manually drawn regions and dividedmore » by localizer length to determine average width. Data were collected for 50 head exams (lateral localizer only), 15 head/neck exams, 50 chest exams, and 50 abdomen/pelvis exams. Mean patient widths and acquisition techniques were used to calculate the weighted average free-in-air KERMA, which was multiplied by the patient area to estimate KAP. Results: Scan technique was 120 kV tube voltage, 10 mA current, and table speed of 10 cm/s. The mean ± standard deviation values of KAP were 120 ± 11.6, 469 ± 62.6, 518 ± 45, and 763 ± 93 mGycm{sup 2} for head, head/neck, chest, and abdomen/pelvis exams, respectively. For studies with AP and lateral localizers, the AP/lateral area ratio was 1.20, 1.33, and 1.24 for the head/neck, chest, and abdomen/pelvis exams, respectively. However, the AP/lateral KAP ratios were 1.12, 1.08, and 1.07, respectively. Conclusion: Calculation of KAP in CT localizers is complicated by the non-uniform intensity profile and z-axis beam width. KAP values are similar to those for simple radiographic exams such as a chest radiograph and represent a small fraction of the x-ray exposure at CT. However, as CT doses are reduced the localizer contribution will be a more significant fraction of the total exposure.« less

  12. US Emergency Department Trends in Imaging for Pediatric Nontraumatic Abdominal Pain.

    PubMed

    Niles, Lauren M; Goyal, Monika K; Badolato, Gia M; Chamberlain, James M; Cohen, Joanna S

    2017-10-01

    To describe national emergency department (ED) trends in computed tomography (CT) and ultrasound imaging for the evaluation of pediatric nontraumatic abdominal pain from 2007 through 2014. We used data from the National Hospital Ambulatory Medical Care Survey to measure trends in CT and ultrasound use among children with nontraumatic abdominal pain. We performed multivariable logistic regression to measure the strength of the association of ED type (pediatric versus general ED) with CT and ultrasound use adjusting for potential confounding variables. Of an estimated 21.1 million ED visits for nontraumatic abdominal pain, 14.6% (95% confidence interval [CI], 13.2%-16.0%) had CT imaging only, 10.9% (95% CI, 9.7%-12.1%) had ultrasound imaging only, and 1.9% (95% CI, 1.4%-2.4%) received both CT and ultrasound. The overall use of CT and ultrasound did not significantly change over the study period ( P trend .63 and .90, respectively). CT use was lower among children treated in pediatric EDs compared with general EDs (adjusted odds ratio 0.34; 95% CI, 0.17-0.69). Conversely, ultrasound use was higher among children treated in pediatric EDs compared with general EDs (adjusted odds ratio 2.14; 95% CI, 1.29-3.55). CT imaging for pediatric patients with nontraumatic abdominal pain has plateaued since 2007 after the steady increase seen in the preceding 9 years. Among this population, an increased likelihood of CT imaging was demonstrated in general EDs compared with pediatric EDs, in which there was a higher likelihood of ultrasound imaging. Dissemination of pediatric-focused radiology protocols to general EDs may help optimize radiation exposure in children. Copyright © 2017 by the American Academy of Pediatrics.

  13. Jejunal perforation after abdominal liposuction, bilateral breast augmentation and facial fat grafting

    PubMed Central

    Coronado-Malagón, Martin; Tauffer-Carrion, Luis Tomas

    2012-01-01

    A 54-year-old woman presented to the emergency department 24 h after undergoing abdominal liposuction, bilateral breast augmentation and facial fat grafting at a private plastic surgery clinic. She presented with the classic evolution of a bowel perforation secondary to abdominal liposuction. A computed tomography (CT) scan found free air in her abdominal cavity. Based on the CT scan and the persistent pain experienced by the patient, an abdominal laparatomy was urgently performed. A jejunum perforation was found and was treated with a resection of the affected segment followed by intestinal anastomosis. The patient had a successful recovery and was discharged seven days later. The present article also reviews the classical presentation of a bowel perforation following abdominal liposuction. PMID:23997589

  14. Jejunal perforation after abdominal liposuction, bilateral breast augmentation and facial fat grafting.

    PubMed

    Coronado-Malagón, Martin; Tauffer-Carrion, Luis Tomas

    2012-01-01

    A 54-year-old woman presented to the emergency department 24 h after undergoing abdominal liposuction, bilateral breast augmentation and facial fat grafting at a private plastic surgery clinic. She presented with the classic evolution of a bowel perforation secondary to abdominal liposuction. A computed tomography (CT) scan found free air in her abdominal cavity. Based on the CT scan and the persistent pain experienced by the patient, an abdominal laparatomy was urgently performed. A jejunum perforation was found and was treated with a resection of the affected segment followed by intestinal anastomosis. The patient had a successful recovery and was discharged seven days later. The present article also reviews the classical presentation of a bowel perforation following abdominal liposuction.

  15. CT protocol management: simplifying the process by using a master protocol concept.

    PubMed

    Szczykutowicz, Timothy P; Bour, Robert K; Rubert, Nicholas; Wendt, Gary; Pozniak, Myron; Ranallo, Frank N

    2015-07-08

    This article explains a method for creating CT protocols for a wide range of patient body sizes and clinical indications, using detailed tube current information from a small set of commonly used protocols. Analytical expressions were created relating CT technical acquisition parameters which can be used to create new CT protocols on a given scanner or customize protocols from one scanner to another. Plots of mA as a function of patient size for specific anatomical regions were generated and used to identify the tube output needs for patients as a function of size for a single master protocol. Tube output data were obtained from the DICOM header of clinical images from our PACS and patient size was measured from CT localizer radiographs under IRB approval. This master protocol was then used to create 11 additional master protocols. The 12 master protocols were further combined to create 39 single and multiphase clinical protocols. Radiologist acceptance rate of exams scanned using the clinical protocols was monitored for 12,857 patients to analyze the effectiveness of the presented protocol management methods using a two-tailed Fisher's exact test. A single routine adult abdominal protocol was used as the master protocol to create 11 additional master abdominal protocols of varying dose and beam energy. Situations in which the maximum tube current would have been exceeded are presented, and the trade-offs between increasing the effective tube output via 1) decreasing pitch, 2) increasing the scan time, or 3) increasing the kV are discussed. Out of 12 master protocols customized across three different scanners, only one had a statistically significant acceptance rate that differed from the scanner it was customized from. The difference, however, was only 1% and was judged to be negligible. All other master protocols differed in acceptance rate insignificantly between scanners. The methodology described in this paper allows a small set of master protocols to be

  16. CT protocol management: simplifying the process by using a master protocol concept

    PubMed Central

    Bour, Robert K.; Rubert, Nicholas; Wendt, Gary; Pozniak, Myron; Ranallo, Frank N.

    2015-01-01

    This article explains a method for creating CT protocols for a wide range of patient body sizes and clinical indications, using detailed tube current information from a small set of commonly used protocols. Analytical expressions were created relating CT technical acquisition parameters which can be used to create new CT protocols on a given scanner or customize protocols from one scanner to another. Plots of mA as a function of patient size for specific anatomical regions were generated and used to identify the tube output needs for patients as a function of size for a single master protocol. Tube output data were obtained from the DICOM header of clinical images from our PACS and patient size was measured from CT localizer radiographs under IRB approval. This master protocol was then used to create 11 additional master protocols. The 12 master protocols were further combined to create 39 single and multiphase clinical protocols. Radiologist acceptance rate of exams scanned using the clinical protocols was monitored for 12,857 patients to analyze the effectiveness of the presented protocol management methods using a two‐tailed Fisher's exact test. A single routine adult abdominal protocol was used as the master protocol to create 11 additional master abdominal protocols of varying dose and beam energy. Situations in which the maximum tube current would have been exceeded are presented, and the trade‐offs between increasing the effective tube output via 1) decreasing pitch, 2) increasing the scan time, or 3) increasing the kV are discussed. Out of 12 master protocols customized across three different scanners, only one had a statistically significant acceptance rate that differed from the scanner it was customized from. The difference, however, was only 1% and was judged to be negligible. All other master protocols differed in acceptance rate insignificantly between scanners. The methodology described in this paper allows a small set of master protocols to be

  17. Elimination of CT-detected gas bubbles derived from decompression illness with abdominal symptoms after a short hyperbaric oxygen treatment in a monoplace chamber: a case report.

    PubMed

    Oyaizu, Takuya; Enomoto, Mitsuhiro; Tsujimoto, Toshihide; Kojima, Yasushi; Okawa, Atsushi; Yagishita, Kazuyoshi

    2017-01-01

    We report the case of a 54-year-old male compressed-air worker with gas bubbles detected by computed tomography (CT). He had complained of strong abdominal pain 30 minutes after decompression after working at a pressure equivalent to 17 meters of sea water for three hours. The initial CT images revealed gas bubbles in the intrahepatic portal vein, pulmonary artery and bilateral femoral vein. After the first hyperbaric oxygen treatment (HBO₂ at 2.5 atmospheres absolute/ATA for 150 minutes), no bubbles were detected on repeat CT examination. The patient still exhibited abdominal distension, mild hypesthesia and slight muscle weakness in the upper extremities. Two sessions of U.S. Navy Treatment Table 6 (TT6) were performed on Days 6 and 7 after onset. The patient recovered completely on Day 7. This report describes the important role of CT imaging in evaluating intravascular gas bubbles as well as eliminating the diagnosis of other conditions when divers or compressed-air workers experience uncommon symptoms of decompression illness. In addition, a short treatment table of HBO₂ using non-TT6 HBO₂ treatment may be useful to reduce gas bubbles and the severity of decompression illness in emergent cases. Copyright© Undersea and Hyperbaric Medical Society.

  18. Diabetes eye exams

    MedlinePlus

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... Ophthalmology Retina/Vitreous Panel. Preferred Practice Pattern ... www.aao.org/preferred-practice-pattern/diabetic-retinopathy- ...

  19. Congenital heart disease manifested as acute abdominal pain.

    PubMed

    Macha, Mahender; Gupta, Dipin; Molina, Ezequiel; Palma, Jon; Rothman, Steven

    2007-06-12

    We present a case of a 53-year-old man with complaints of severe abdominal pain and nausea. Emergency department abdominal workup was non-diagnostic. Physical examination revealed signs of right- and left-heart failure. A past medical history of dysrhythmias and chronic abdominal complaints prompted hospital admission. Subsequent right heart catheterization revealed a significant left-to-right shunt. CT scan of the chest and angiography confirmed the diagnosis of an abnormal ascending vein between the innominate vein and the left superior pulmonary vein. After the anomalous vein was ligated, the patient's abdominal pain resolved.

  20. An incidentally found inflamed uterine myoma causing low abdominal pain, using Tc-99m-tektrotyd single photon emission computed tomography-CT hybrid imaging.

    PubMed

    Zandieh, Shahin; Schütz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg

    2013-01-01

    We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated chromogranin A-level was caused by the hypertension that the patient presented. In the clinical context, this is a report of an inflamed uterine myoma seen as a false positive result detected by TC-99m-Tc-EDDA/HYNIC-Tyr3-Octreotide (Tektrotyd) SPECT-CT hybrid imaging.

  1. Poster - 03: How to manage a nuclear medicine PET-CT for radiation oncology patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinse, Martin; Létourneau, Étienne; Duplan, Danny

    Purpose: Development of an adapted multidisciplinary procedure designed to optimize the clinical workflow between radiation therapy (RT) and nuclear medicine (NM) for a PET-CT located in the NM department. Methods : The radiation oncologist (RO) prescribes the PET-CT exam and the clinical RT therapist gives all the necessary information to the patient prior to the exam. The immobilization accessories are prepared in the RT department. The RT and NM therapists work together for radiotracer injection, patient positioning and scan acquisition. The nuclear medicine physician (NMP) will study the images, draw Biological Target Volumes (BTVs) and produce a full exam report.more » Results : All tasks related to a planning PET-CT are done within 48 hours from the request by the RO to the reception of the images with the NMP contours and report. Conclusions : By developing a complete procedure collectively between the RT and NM departments, the patient benefits of a quick access to a RT planning PET-CT exam including the active involvement of every medical practitioners in these fields.« less

  2. Computer-Aided Diagnosis of Splenic Enlargement Using Wave Pattern of Spleen in Abdominal CT Images: Initial Observations

    NASA Astrophysics Data System (ADS)

    Seong, Won; Cho, June-Sik; Noh, Seung-Moo; Park, Jong-Won

    In general, the spleen accompanied by abnormal abdomen is hypertrophied. However, if the spleen size is originally small, it is hard to detect the splenic enlargement due to abnormal abdomen by simply measure the size. On the contrary, the spleen size of a person having a normal abdomen may be large by nature. Therefore, measuring the size of spleen is not a reliable diagnostic measure of its enlargement or the abdomen abnormality. This paper proposes an automatic method to diagnose the splenic enlargement due to abnormality, by examining the boundary pattern of spleen in abdominal CT images.

  3. Estimating abdominal adipose tissue with DXA and anthropometry.

    PubMed

    Hill, Alison M; LaForgia, Joe; Coates, Alison M; Buckley, Jonathan D; Howe, Peter R C

    2007-02-01

    To identify an anatomically defined region of interest (ROI) from DXA assessment of body composition that when combined with anthropometry can be used to accurately predict intra-abdominal adipose tissue (IAAT) in overweight/obese individuals. Forty-one postmenopausal women (age, 49 to 66 years; BMI, 26 to 37 kg/m(2)) underwent anthropometric and body composition assessments. ROI were defined as quadrilateral boxes extending 5 or 10 cm above the iliac crest and laterally to the edges of the abdominal soft tissue. A single-slice computed tomography (CT) scan was measured at the L3 to L4 intervertebral space, and abdominal skinfolds were taken. Forward step-wise regression revealed the best predictor model of IAAT area measured by CT (r(2) = 0.68, standard error of estimate = 17%) to be: IAAT area (centimeters squared) = 51.844 + DXA 10-cm ROI (grams) (0.031) + abdominal skinfold (millimeters) (1.342). Interobserver reliability for fat mass (r = 0.994; coefficient of variation, 2.60%) and lean mass (r = 0.986, coefficient of variation, 2.67%) in the DXA 10-cm ROI was excellent. This study has identified a DXA ROI that can be reliably measured using prominent anatomical landmarks, in this case, the iliac crest. Using this ROI, combined with an abdominal skinfold measurement, we have derived an equation to predict IAAT in overweight/obese postmenopausal women. This approach offers a simpler, safer, and more cost-effective method than CT for assessing the efficacy of lifestyle interventions aimed at reducing IAAT. However, this warrants further investigation and validation with an independent cohort.

  4. Can We Perform CT of the Appendix with Less Than 1 mSv? A De-escalating Dose-simulation Study.

    PubMed

    Park, Ji Hoon; Jeon, Jong-June; Lee, Sung Soo; Dhanantwari, Amar C; Sim, Ji Ye; Kim, Hae Young; Lee, Kyoung Ho

    2018-05-01

    To systematically explore the lowest reasonably achievable radiation dose for appendiceal CT using an iterative reconstruction (IR) in young adults. We prospectively included 30 patients who underwent 2.0-mSv CT for suspected appendicitis. From the helical projection data, 1.5-, 1.0- and 0.5-mSv CTs were generated using a low-dose simulation tool and the knowledge-based IR. We performed step-wise non-inferiority tests sequentially comparing 2.0-mSv CT with each of 1.5-, 1.0- and 0.5-mSv CT, with a predetermined non-inferiority margin of 0.06. The primary end point was the pooled area under the receiver-operating-characteristic curve (AUC) for three abdominal and three non-abdominal radiologists. For the abdominal radiologists, the non-inferiorities of 1.5-, 1.0- and 0.5-mSv CT to 2.0-mSv CT were sequentially accepted [pooled AUC difference: 2.0 vs. 0.5 mSv, 0.017 (95% CI: -0.016, 0.050)]. For the non-abdominal radiologists, the non-inferiorities of 1.5- and 1.0-mSv CT were accepted; however, the non-inferiority of 0.5-mSv CT could not be proved [pooled AUC difference: 2.0 vs. 1.0 mSv, -0.017 (-0.070, 0.035) and 2.0 vs. 0.5 mSv, 0.045 (-0.071, 0.161)]. The 1.0-mSv appendiceal CT was non-inferior to 2.0-mSv CT in terms of diagnostic performance for both abdominal and non-abdominal radiologists; 0.5-mSv appendiceal CT was non-inferior only for abdominal radiologists. • For both abdominal and non-abdominal radiologists, 1.0-mSv appendiceal CT could be feasible. • The 0.5-mSv CT was non-inferior to 2.0-mSv CT only for expert abdominal radiologists. • Reader experience is an important factor affecting diagnostic impairment by low-dose CT.

  5. [Abdomen specific bioelectrical impedance analysis (BIA) methods for evaluation of abdominal fat distribution].

    PubMed

    Ida, Midori; Hirata, Masakazu; Hosoda, Kiminori; Nakao, Kazuwa

    2013-02-01

    Two novel bioelectrical impedance analysis (BIA) methods have been developed recently for evaluation of intra-abdominal fat accumulation. Both methods use electrodes that are placed on abdominal wall and allow evaluation of intra-abdominal fat area (IAFA) easily without radiation exposure. Of these, "abdominal BIA" method measures impedance distribution along abdominal anterior-posterior axis, and IAFA by BIA method(BIA-IAFA) is calculated from waist circumference and the voltage occurring at the flank. Dual BIA method measures impedance of trunk and body surface at the abdominal level and calculates BIA-IAFA from transverse and antero-posterior diameters of the abdomen and the impedance of trunk and abdominal surface. BIA-IAFA by these two BIA methods correlated well with IAFA measured by abdominal CT (CT-IAFA) with correlatipn coefficient of 0.88 (n = 91, p < 0.0001) for the former, and 0.861 (n = 469, p < 0.01) for the latter. These new BIA methods are useful for evaluating abdominal adiposity in clinical study and routine clinical practice of metabolic syndrome and obesity.

  6. [Diagnostic management in paediatric blunt abdominal trauma - a systematic review with metaanalysis].

    PubMed

    Schöneberg, C; Tampier, S; Hussmann, B; Lendemans, S; Waydhas, C

    2014-12-01

    The objective of this systematic review was to investigate the diagnostic management in paediatric blunt abdominal injuries. A literature research was performed using following sources: MEDLINE, Embase and Cochrane. Where it was possible a meta-analysis was performed. Furthermore the level of evidence for all publications was assigned. Indicators for intraabdominal injury (IAI) were elevated liver transaminases, abnormal abdominal examinations, low systolic blood pressure, reduced haematocrit and microhematuria. Detecting IAI with focused assessment with sonography for trauma (FAST) had an overall sensitivity of 56.5 %, a specificity of 94.68 %, a positive likelihood ratio of 10.63 and a negative likelihood ratio of 0.46. The accuracy was 84.02 %. Among haemodynamically unstable children the sensitivity and specificity were 100 %. The overall prevalence of IAI and negative CT was 0.19 %. The NPV of abdominal CT for diagnosing IAI was 99.8 %. The laparotomy rate in patients with isolated intraperitoneal fluid (IIF) in one location was 3.48 % and 56.52 % in patients with IIF in more than one location. FAST as an isolated tool in the diagnostics after blunt abdominal injury is very uncertain, because of the modest sensitivity. Discharging children after blunt abdominal trauma with a negative abdominal CT scan seems to be safe. When IIF is detected on CT scan, it depends on the number of locations involved. If IIF is found only in 1 location, IAI is uncommon, while IIF in two or more locations results in a high laparotomy rate. Georg Thieme Verlag KG Stuttgart · New York.

  7. Computerized organ localization in abdominal CT volume with context-driven generalized Hough transform

    NASA Astrophysics Data System (ADS)

    Liu, Jing; Li, Qiang

    2014-03-01

    Fast localization of organs is a key step in computer-aided detection of lesions and in image guided radiation therapy. We developed a context-driven Generalized Hough Transform (GHT) for robust localization of organ-of-interests (OOIs) in a CT volume. Conventional GHT locates the center of an organ by looking-up center locations of pre-learned organs with "matching" edges. It often suffers from mislocalization because "similar" edges in vicinity may attract the prelearned organs towards wrong places. The proposed method not only uses information from organ's own shape but also takes advantage of nearby "similar" edge structures. First, multiple GHT co-existing look-up tables (cLUT) were constructed from a set of training shapes of different organs. Each cLUT represented the spatial relationship between the center of the OOI and the shape of a co-existing organ. Second, the OOI center in a test image was determined using GHT with each cLUT separately. Third, the final localization of OOI was based on weighted combination of the centers obtained in the second stage. The training set consisted of 10 CT volumes with manually segmented OOIs including liver, spleen and kidneys. The method was tested on a set of 25 abdominal CT scans. Context-driven GHT correctly located all OOIs in the test image and gave localization errors of 19.5±9.0, 12.8±7.3, 9.4±4.6 and 8.6±4.1 mm for liver, spleen, left and right kidney respectively. Conventional GHT mis-located 8 out of 100 organs and its localization errors were 26.0±32.6, 14.1±10.6, 30.1±42.6 and 23.6±39.7mm for liver, spleen, left and right kidney respectively.

  8. CFD modelling of abdominal aortic aneurysm on hemodynamic loads using a realistic geometry with CT.

    PubMed

    Soudah, Eduardo; Ng, E Y K; Loong, T H; Bordone, Maurizio; Pua, Uei; Narayanan, Sriram

    2013-01-01

    The objective of this study is to find a correlation between the abdominal aortic aneurysm (AAA) geometric parameters, wall stress shear (WSS), abdominal flow patterns, intraluminal thrombus (ILT), and AAA arterial wall rupture using computational fluid dynamics (CFD). Real AAA 3D models were created by three-dimensional (3D) reconstruction of in vivo acquired computed tomography (CT) images from 5 patients. Based on 3D AAA models, high quality volume meshes were created using an optimal tetrahedral aspect ratio for the whole domain. In order to quantify the WSS and the recirculation inside the AAA, a 3D CFD using finite elements analysis was used. The CFD computation was performed assuming that the arterial wall is rigid and the blood is considered a homogeneous Newtonian fluid with a density of 1050 kg/m(3) and a kinematic viscosity of 4 × 10(-3) Pa·s. Parallelization procedures were used in order to increase the performance of the CFD calculations. A relation between AAA geometric parameters (asymmetry index ( β ), saccular index ( γ ), deformation diameter ratio ( χ ), and tortuosity index ( ε )) and hemodynamic loads was observed, and it could be used as a potential predictor of AAA arterial wall rupture and potential ILT formation.

  9. Discriminative dictionary learning for abdominal multi-organ segmentation.

    PubMed

    Tong, Tong; Wolz, Robin; Wang, Zehan; Gao, Qinquan; Misawa, Kazunari; Fujiwara, Michitaka; Mori, Kensaku; Hajnal, Joseph V; Rueckert, Daniel

    2015-07-01

    An automated segmentation method is presented for multi-organ segmentation in abdominal CT images. Dictionary learning and sparse coding techniques are used in the proposed method to generate target specific priors for segmentation. The method simultaneously learns dictionaries which have reconstructive power and classifiers which have discriminative ability from a set of selected atlases. Based on the learnt dictionaries and classifiers, probabilistic atlases are then generated to provide priors for the segmentation of unseen target images. The final segmentation is obtained by applying a post-processing step based on a graph-cuts method. In addition, this paper proposes a voxel-wise local atlas selection strategy to deal with high inter-subject variation in abdominal CT images. The segmentation performance of the proposed method with different atlas selection strategies are also compared. Our proposed method has been evaluated on a database of 150 abdominal CT images and achieves a promising segmentation performance with Dice overlap values of 94.9%, 93.6%, 71.1%, and 92.5% for liver, kidneys, pancreas, and spleen, respectively. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging.

    PubMed

    Pickhardt, Perry J; Lubner, Meghan G; Kim, David H; Tang, Jie; Ruma, Julie A; del Rio, Alejandro Muñoz; Chen, Guang-Hong

    2012-12-01

    The purpose of this study was to report preliminary results of an ongoing prospective trial of ultralow-dose abdominal MDCT. Imaging with standard-dose contrast-enhanced (n = 21) and unenhanced (n = 24) clinical abdominal MDCT protocols was immediately followed by ultralow-dose imaging of a matched series of 45 consecutively registered adults (mean age, 57.9 years; mean body mass index, 28.5). The ultralow-dose images were reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Standard-dose series were reconstructed with FBP (reference standard). Image noise was measured at multiple predefined sites. Two blinded abdominal radiologists interpreted randomly presented ultralow-dose images for multilevel subjective image quality (5-point scale) and depiction of organ-based focal lesions. Mean dose reduction relative to the standard series was 74% (median, 78%; range, 57-88%; mean effective dose, 1.90 mSv). Mean multiorgan image noise for low-dose MBIR was 14.7 ± 2.6 HU, significantly lower than standard-dose FBP (28.9 ± 9.9 HU), low-dose FBP (59.2 ± 23.3 HU), and ASIR (45.6 ± 14.1 HU) (p < 0.001). The mean subjective image quality score for low-dose MBIR (3.0 ± 0.5) was significantly higher than for low-dose FBP (1.6 ± 0.7) and ASIR (1.8 ± 0.7) (p < 0.001). Readers identified 213 focal noncalcific lesions with standard-dose FBP. Pooled lesion detection was higher for low-dose MBIR (79.3% [169/213]) compared with low-dose FBP (66.2% [141/213]) and ASIR (62.0% [132/213]) (p < 0.05). MBIR shows great potential for substantially reducing radiation doses at routine abdominal CT. Both FBP and ASIR are limited in this regard owing to reduced image quality and diagnostic capability. Further investigation is needed to determine the optimal dose level for MBIR that maintains adequate diagnostic performance. In general, objective and subjective image quality measurements do

  11. Effective and organ doses from common CT examinations in one general hospital in Tehran, Iran

    NASA Astrophysics Data System (ADS)

    Khoramian, Daryoush; Hashemi, Bijan

    2017-09-01

    Purpose: It is well known that the main portion of artificial sources of ionizing radiation to human results from X-ray imaging techniques. However, reports carried out in various countries have indicated that most of their cumulative doses from artificial sources are due to CT examinations. Hence assessing doses resulted from CT examinations is highly recommended by national and international radiation protection agencies. The aim of this research has been to estimate the effective and organ doses in an average human according to 103 and 60 ICRP tissue weighting factor for six common protocols of Multi-Detector CT (MDCT) machine in a comprehensive training general hospital in Tehran/Iran. Methods: To calculate the patients' effective dose, the CT-Expo2.2 software was used. Organs/tissues and effective doses were determined for about 20 patients (totally 122 patients) for every one of six typical CT protocols of the head, neck, chest, abdomen-pelvis, pelvis and spine exams. In addition, the CT dosimetry index (CTDI) was measured in the standard 16 and 32 cm phantoms by using a calibrated pencil ionization chamber for the six protocols and by taking the average value of CT scan parameters used in the hospital compared with the CTDI values displayed on the console device of the machine. Results: The values of the effective dose based on the ICRP 103 tissue weighting factor were: 0.6, 2.0, 3.2, 4.2, 2.8, and 3.9 mSv and based on the ICRP 60 tissue weighting factor were: 0.9, 1.4, 3, 7.9, 4.8 and 5.1 mSv for the head, neck, chest, abdomen-pelvis, pelvis, spine CT exams respectively. Relative differences between those values were -22, 21, 23, -6, -31 and 16 percent for the head, neck, chest, abdomen-pelvis, pelvis, spine CT exams, respectively. The average value of CTDIv calculated for each protocol was: 27.32 ± 0.9, 18.08 ± 2.0, 7.36 ± 2.6, 8.84 ± 1.7, 9.13 ± 1.5, 10.42 ± 0.8 mGy for the head, neck, chest, abdomen-pelvis and spine CT exams, respectively

  12. Practical human abdominal fat imaging utilizing electrical impedance tomography.

    PubMed

    Yamaguchi, T; Maki, K; Katashima, M

    2010-07-01

    The fundamental cause of metabolic syndrome is thought to be abdominal obesity. Accurate diagnosis of abdominal obesity can be done by an x-ray computed tomography (CT) scan. But CT is expensive, bulky and entails the risks involved with radiation. To overcome such disadvantages, we attempted to develop a measuring device that could apply electrical impedance tomography to abdominal fat imaging. The device has 32 electrodes that can be attached to a subject's abdomen by a pneumatic mechanism. That way, electrode position data can be acquired simultaneously. An applied alternating current of 1.0 mArms was used at a frequency of 500 kHz. Sensed voltage data were carefully filtered to remove noise and processed to satisfy the reciprocal theorem. The image reconstruction software was developed concurrently, applying standard finite element methods and the Marquardt method to solve the mathematical inverse problem. The results of preliminary experiments showed that abdominal subcutaneous fat and the muscle surrounding the viscera could be imaged in humans. While our imaging of visceral fat was not of sufficient quality, it was suggested that we will be able to develop a safe and practical abdominal fat scanner through future improvements.

  13. Standard eye exam

    MedlinePlus

    Standard ophthalmic exam; Routine eye examination; Eye exam - standard; Annual eye exam ... Comprehensive adult medical eye evaluation preferred practice pattern guidelines. Ophthalmology . 2016;123(1):209-236. PMID: 26581558 ...

  14. Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT.

    PubMed

    Euler, André; Obmann, Markus M; Szucs-Farkas, Zsolt; Mileto, Achille; Zaehringer, Caroline; Falkowski, Anna L; Winkel, David J; Marin, Daniele; Stieltjes, Bram; Krauss, Bernhard; Schindera, Sebastian T

    2018-02-19

    To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-DECT (n = 100). SF-DECT scans were reconstructed and subdivided into composed images (SF-CI) and monoenergetic images at 55 keV (SF-MI). Objective and subjective image quality were compared among single-energy images (SEI), SF-CI and SF-MI. CNR and FOM were separately calculated for the liver (e.g. CNR liv ) and the portal vein (CNR pv ). Radiation dose was compared using size-specific dose estimate (SSDE). Results of the three groups were compared using non-parametric tests. Image noise of SF-CI was 18% lower compared to SEI and 48% lower compared to SF-MI (p < 0.001). Composed images yielded higher CNR liv over single-energy images (23.4 vs. 20.9; p < 0.001), whereas CNR pv was significantly lower (3.5 vs. 5.2; p < 0.001). Monoenergetic images overcame this inferiority in CNR pv and achieved similar results compared to single-energy images (5.1 vs. 5.2; p > 0.628). Subjective sharpness was equal between single-energy and monoenergetic images and diagnostic confidence was equal between single-energy and composed images. FOM liv was highest for SF-CI. FOM pv was equal for SEI and SF-MI (p = 0.78). SSDE was significant lower for SF-DECT compared to SECT (p < 0.022). The combined use of split-filter dual-energy CT images provides comparable objective and subjective image quality at lower radiation dose compared to single-energy CT with ATVS. • Split-filter dual-energy results in 18% lower noise compared to single-energy with ATVS. • Split-filter dual-energy results in 11% lower SSDE compared to single-energy with ATVS. • Spectral shaping of split-filter dual-energy leads to an increased dose-efficiency.

  15. Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function.

    PubMed

    Nagayama, Yasunori; Tanoue, Shota; Tsuji, Akinori; Urata, Joji; Furusawa, Mitsuhiro; Oda, Seitaro; Nakaura, Takeshi; Utsunomiya, Daisuke; Yoshida, Eri; Yoshida, Morikatsu; Kidoh, Masafumi; Tateishi, Machiko; Yamashita, Yasuyuki

    2018-05-01

    To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal-pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. We included 45 patients with renal dysfunction (estimated glomerular filtration rate  <45 ml per min per 1.73 m 2 ) who underwent reduced-CM abdominal-pelvic CT (360 mgI kg -1 , 80-kVp, SAFIRE) for oncological assessment. Another 45 patients without renal dysfunction (estimated glomerular filtration rate >60 ml per lmin per 1.73 m 2 ) who underwent standard oncological abdominal-pelvic CT (600 mgI kg -1 , 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1-3 months after CT were measured. The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p < 0.01). CT attenuation and contrast-to-noise ratio of parenchymal organs and vessels in 80-kVp images were significantly better than those of 120-kVp images (p < 0.05). There were no significant differences in quantitative or qualitative image noise or subjective overall quality (p > 0.05). No significant kidney injury associated with CM administration was observed. 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.

  16. Abdominal emergencies in pediatrics.

    PubMed

    Coca Robinot, D; Liébana de Rojas, C; Aguirre Pascual, E

    2016-05-01

    Abdominal symptoms are among the most common reasons for pediatric emergency department visits, and abdominal pain is the most frequently reported symptom. Thorough history taking and physical examination can often reach the correct diagnosis. Knowing the abdominal conditions that are most common in each age group can help radiologists narrow the differential diagnosis. When imaging tests are indicated, ultrasonography is usually the first-line technique, enabling the diagnosis or adding relevant information with the well-known advantages of this technique. Nowadays, plain-film X-ray studies are reserved for cases in which perforation, bowel obstruction, or foreign body ingestion is suspected. It is also important to remember that abdominal pain can also occur secondary to basal pneumonia. CT is reserved for specific indications and in individual cases, for example, in patients with high clinical suspicion of abdominal disease and inconclusive findings at ultrasonography. We review some of the most common conditions in pediatric emergencies, the different imaging tests indicated in each case, and the imaging signs in each condition. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  17. Hollow organ perforation in blunt abdominal trauma: the role of diagnostic peritoneal lavage.

    PubMed

    Wang, Yu-Chun; Hsieh, Chi-Hsun; Fu, Chih-Yuan; Yeh, Chun-Chieh; Wu, Shih-Chi; Chen, Ray-Jade

    2012-05-01

    With recent advances in radiologic diagnostic procedures, the use of diagnostic peritoneal lavage (DPL) has markedly declined. In this study, we reviewed data to reevaluate the role of DPL in the diagnosis of hollow organ perforation in patients with blunt abdominal trauma. Adult patients who had sustained blunt abdominal trauma and who were hemodynamically stable after initial resuscitation underwent an abdominal computed tomographic (CT) scan. Diagnostic peritoneal lavage was performed for patients who were indicated to receive nonoperative management and where hollow organ perforation could not be ruled out. During a 60-month period, 64 patients who had received abdominal CT scanning underwent DPL. Nineteen patients were diagnosed as having a positive DPL based on cell count ratio of 1 or higher. There were 4 patients who sustained small bowel perforation. The sensitivity and specificity of the cell count ratio for a hollow organ perforation in this study were 100% and 75%, respectively. No missed hollow organ perforations were detected. For patients with blunt abdominal trauma and hemoperitoneum who plan to receive nonoperative management, DPL is still a useful tool to exclude hollow organ perforation that is undetected by CT. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Selective Nonoperative Management of Penetrating Abdominal Solid Organ Injuries

    PubMed Central

    Demetriades, Demetrios; Hadjizacharia, Pantelis; Constantinou, Costas; Brown, Carlos; Inaba, Kenji; Rhee, Peter; Salim, Ali

    2006-01-01

    Objective: To assess the feasibility and safety of selective nonoperative management in penetrating abdominal solid organ injuries. Background: Nonoperative management of blunt abdominal solid organ injuries has become the standard of care. However, routine surgical exploration remains the standard practice for all penetrating solid organ injuries. The present study examines the role of nonoperative management in selected patients with penetrating injuries to abdominal solid organs. Patients and Methods: Prospective, protocol-driven study, which included all penetrating abdominal solid organ (liver, spleen, kidney) injuries admitted to a level I trauma center, over a 20-month period. Patients with hemodynamic instability, peritonitis, or an unevaluable abdomen underwent an immediate laparotomy. Patients who were hemodynamically stable and had no signs of peritonitis were selected for further CT scan evaluation. In the absence of CT scan findings suggestive of hollow viscus injury, the patients were observed with serial clinical examinations, hemoglobin levels, and white cell counts. Patients with left thoracoabdominal injuries underwent elective laparoscopy to rule out diaphragmatic injury. Outcome parameters included survival, complications, need for delayed laparotomy in observed patients, and length of hospital stay. Results: During the study period, there were 152 patients with 185 penetrating solid organ injuries. Gunshot wounds accounted for 70.4% and stab wounds for 29.6% of injuries. Ninety-one patients (59.9%) met the criteria for immediate operation. The remaining 61 (40.1%) patients were selected for CT scan evaluation. Forty-three patients (28.3% of all patients) with 47 solid organ injuries who had no CT scan findings suspicious of hollow viscus injury were selected for clinical observation and additional laparoscopy in 2. Four patients with a “blush” on CT scan underwent angiographic embolization of the liver. Overall, 41 patients (27

  19. Can Abdominal CT Imaging Help Accurately Identify a Dedifferentiated Component in a Well-Differentiated Liposarcoma?

    PubMed Central

    Bhosale, Priya; Wang, Jieqi; Varma, Datla G.K; Jensen, Corey; Patnana, Madhavi; Wei, Wei; Chauhan, Anil; Feig, Barry; Patel, Shreyaskumar; Somaiah, Neeta; Sagebiel, Tara

    2016-01-01

    Purpose To assess the ability of CT to differentiate an atypical lipomatous tumor (ALT)/well-differentiated liposarcoma (WDLPS) from a WDLPS with a dedifferentiated component (DDLPS) within it. Materials and Methods Forty-nine untreated patients with abdominal atypical lipomatous tumors/well-differentiated liposarcomas who had undergone contrast-enhanced CT were identified using an institutional database. Three radiologists who were blinded to the pathology findings evaluated all the images independently to determine whether a dedifferentiated component was present within the WDLPS. The CT images were evaluated for fat content (≤25% or >25%); presence of ground-glass density, enhancing and/or necrotic nodules; presence of a capsule surrounding the mass; septations; and presence and pattern of calcifications. A multivariate logistic regression model with generalized estimating equations was used to correlate imaging features with pathology findings. Kappa statistics were calculated to assess agreement between the three radiologists. Results On the basis of pathological findings, 12 patients had been diagnosed with DDLPS within a WDLPS and 37 had been diagnosed with WDLPS. The presence of an enhancing or a centrally necrotic nodule within the atypical lipomatous tumor was associated with dedifferentiated liposarcoma (p = 0.02 and p = 0.0003, respectively). The three readers showed almost perfect agreement in overall diagnosis (kappa r = 0.83; 95% confidence-interval 0.67 to 0.99). Conclusion An enhancing or centrally necrotic nodule may be indicative of a dedifferentiated component in well-differentiated liposarcoma. Ground-glass density nodules may not be indicative of dedifferentiation. PMID:27454788

  20. High pitch third generation dual-source CT: Coronary and Cardiac Visualization on Routine Chest CT

    PubMed Central

    Sandfort, Veit; Ahlman, Mark; Jones, Elizabeth; Selwaness, Mariana; Chen, Marcus; Folio, Les; Bluemke, David A.

    2016-01-01

    Background Chest CT scans are frequently performed in radiology departments but have not previously contained detailed depiction of cardiac structures. Objectives To evaluate myocardial and coronary visualization on high-pitch non-gated CT of the chest using 3rd generation dual-source computed tomography (CT). Methods Cardiac anatomy of patients who had 3rd generation, non-gated high pitch contrast enhanced chest CT and who also had prior conventional (low pitch) chest CT as part of a chest abdomen pelvis exam was evaluated. Cardiac image features were scored by reviewers blinded to diagnosis and pitch. Paired analysis was performed. Results 3862 coronary segments and 2220 cardiac structures were evaluated by two readers in 222 CT scans. Most patients (97.2%) had chest CT for oncologic evaluation. The median pitch was 2.34 (IQR 2.05, 2.65) in high pitch and 0.8 (IQR 0.8, 0.8) in low pitch scans (p<0.001). High pitch CT showed higher image visualization scores for all cardiovascular structures compared with conventional pitch scans (p<0.0001). Coronary arteries were visualized in 9 coronary segments per exam in high pitch scans versus 2 segments for conventional pitch (p<0.0001). Radiation exposure was lower in the high pitch group compared with the conventional pitch group (median CTDIvol 10.83 vs. 12.36 mGy and DLP 790 vs. 827 mGycm respectively, p <0.01 for both) with comparable image noise (p=0.43). Conclusion Myocardial structure and coronary arteries are frequently visualized on non-gated 3rd generation chest CT. These results raise the question of whether the heart and coronary arteries should be routinely interpreted on routine chest CT that is otherwise obtained for non-cardiac indications. PMID:27133589

  1. The association between Chance fractures and intra-abdominal injuries revisited: a multicenter review.

    PubMed

    Tyroch, Alan H; McGuire, Emmett L; McLean, Susan F; Kozar, Rosemary A; Gates, Keith A; Kaups, Krista L; Cook, Charles; Cowgill, Sarah M; Griswold, John A; Sue, Larry A; Craun, Michael L; Price, Jan

    2005-05-01

    The association between Chance fractures and intra-abdominal injuries is reported to be as high as 89 per cent. Because prior studies were small series or case reports, we conducted a multicenter review to learn the true association between Chance fractures and intra-abdominal injuries as well as diagnostic trends. Trauma registry data, medical records, and radiology reports from 7 trauma centers were used to characterize 79 trauma patients with Chance fractures. Initial methods of abdominal assessment were computed tomography (CT) scan (79%), clinical examination (16%), and diagnostic peritoneal lavage (DPL) (5%). Twenty-six (33%) patients had intraabdominal injuries of which hollow viscus injuries predominated (22%). Twenty patients (25%) underwent laparotomy. The presence of an abdominal wall contusion and automobile restraint use were highly predictive of intra-abdominal injury and the need for laparotomy. The association between a Chance fracture and intra-abdominal injury is not as high as previously reported. CT scan has become the primary modality to assess the abdominal cavity of patients with Chance fractures, whereas the role of DPL has diminished.

  2. When Should Abdominal Computed Tomography Be Considered in Patients with Lower Rib Fractures?

    PubMed

    Jeroukhimov, Igor; Hershkovitz, Yehuda; Wiser, Itay; Kessel, Boris; Ayyad, Mohammed; Gatot, Inbar; Shapira, Zahar; Jeoravlev, Svetlana; Halevy, Ariel; Lavy, Ron

    2017-05-01

    Lower rib fractures are considered as a marker of intra-abdominal organ injury. Abdominal computed tomography (CT) is the "gold standard" examination for patients with lower rib fractures. However, the reported incidence of concomitant intra-abdominal injuries (IAI) is 20%-40%. The purpose of this study was to evaluate the incidence of intra-abdominal organ injuries in blunt trauma patients with lower rib fractures. Medical charts and radiology reports of patients with lower rib (from the 8th to 12th rib) fractures admitted to our center during a 6-year period were retrospectively reviewed. Patients were divided into two groups. Group I included patients with intra-abdominal injury (IAI) diagnosed either by CT or on urgent laparotomy, and Group II included those with normal abdominal CT scans. Data included demographics, mechanism of injury, laboratory tests, radiology results including number and location of fractured ribs, and incidence of IAI. Overall 318 patients were included in the study. Fifty-seven patients (17.9%) had 71 IAIs compared with 265 (82.1%) patients with no IAI. Logistic regression identified age younger than 55 years (relative risk [RR] = 7.2; 95% confidence interval [CI] 3.1-16.8; p = 0.001), bilateral rib fractures (RR = 3.9; 95% CI 1.1-13.5; p = 0.03) and decreased levels of hematocrit (RR = 2.4; 95% CI 1.2-4.8; p = 0.016) as independent risk factors for the presence of IAI. Abdominal CT should be considered in blunt trauma patients with lower rib fractures who are younger than 55 years of age and have bilateral rib fractures and decreased levels of hematocrit on admission. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Intra-abdominal fat: Comparison of computed tomography fat segmentation and bioimpedance spectroscopy.

    PubMed

    Finch, Peter

    2017-06-01

    Intra-abdominal fat is an important factor in determining the metabolic syndrome/insulin resistance, and thus the risk of diabetes and ischaemic heart disease. Computed Tomography (CT) fat segmentation represents a defined method of quantifying intra-abdominal fat, with attendant radiation risks. Bioimpedance spectroscopy may offer a method of assessment without any risks to the patients. A comparison is made of these two methods. This was a preliminary study of the utility of multifrequency bioimpedance spectroscopy of the mid abdomen as a measure of intra-abdominal fat, by comparison with fat segmentation of an abdominal CT scan in the -30 to -190 HU range. There was a significant (P < 0.01) correlation between intra-abdominal fat and mid-upper arm circumference, as well as the bioimpedance parameter, the R/S ratio. Multivariate analysis showed that these were the only independant variables and allowed the derivation of a formula to estimate intra-abdominal fat: IAF = 0.02 × MAC - 0.757 × R/S + 0.036. Circumabdominal bioimpedance spectroscopy may prove a useful method of assessing intra-abdominal fat, and may be suitable for use in studies to enhance other measures of body composition, such as mid-upper arm circumference.

  4. Quality of routine diagnostic abdominal images generated from a novel detector-based spectral CT scanner: a technical report on a phantom and clinical study.

    PubMed

    Hojjati, Mojgan; Van Hedent, Steven; Rassouli, Negin; Tatsuoka, Curtis; Jordan, David; Dhanantwari, Amar; Rajiah, Prabhakar

    2017-11-01

    To evaluate the image quality of routine diagnostic images generated from a novel detector-based spectral detector CT (SDCT) and compare it with CT images obtained from a conventional scanner with an energy-integrating detector (Brilliance iCT), Routine diagnostic (conventional/polyenergetic) images are non-material-specific images that resemble single-energy images obtained at the same radiation, METHODS: ACR guideline-based phantom evaluations were performed on both SDCT and iCT for CT adult body protocol. Retrospective analysis was performed on 50 abdominal CT scans from each scanner. Identical ROIs were placed at multiple locations in the abdomen and attenuation, noise, SNR, and CNR were measured. Subjective image quality analysis on a 5-point Likert scale was performed by 2 readers for enhancement, noise, and image quality. On phantom studies, SDCT images met the ACR requirements for CT number and deviation, CNR and effective radiation dose. In patients, the qualitative scores were significantly higher for the SDCT than the iCT, including enhancement (4.79 ± 0.38 vs. 4.60 ± 0.51, p = 0.005), noise (4.63 ± 0.42 vs. 4.29 ± 0.50, p = 0.000), and quality (4.85 ± 0.32, vs. 4.57 ± 0.50, p = 0.000). The SNR was higher in SDCT than iCT for liver (7.4 ± 4.2 vs. 7.2 ± 5.3, p = 0.662), spleen (8.6 ± 4.1 vs. 7.4 ± 3.5, p = 0.152), kidney (11.1 ± 6.3 vs. 8.7 ± 5.0, p = 0.033), pancreas (6.90 ± 3.45 vs 6.11 ± 2.64, p = 0.303), aorta (14.2 ± 6.2 vs. 11.0 ± 4.9, p = 0.007), but was slightly lower in lumbar-vertebra (7.7 ± 4.2 vs. 7.8 ± 4.5, p = 0.937). The CNR of the SDCT was also higher than iCT for all abdominal organs. Image quality of routine diagnostic images from the SDCT is comparable to images of a conventional CT scanner with energy-integrating detectors, making it suitable for diagnostic purposes.

  5. Helicobacter pylori gastritis in a child with sickle cell anemia and recurrent abdominal pain.

    PubMed

    Kennedy, L; Mahoney, D H; Redel, C A

    1997-01-01

    Recurrent abdominal pain is a common complaint in children with sickle cell disease. Helicobacter pylori gastritis has recently been described in association with recurrent abdominal pain in children. A case report is given of a 16-year-old black male with hemoglobin SS disease presenting with recurrent abdominal pain and hematemesis. Endoscopic exam of the upper gastrointestinal tract revealed gastritis, and biopsy confirmed H. pylori infection. Serology studies demonstrated increased anti-H. pylori antibody titers. The young man responded well to treatment, with resolution of his symptoms. Helicobacter pylori infection is a new diagnostic consideration for children with recurrent abdominal pain and should be included in the differential diagnosis of children with sickle cell disease, especially when abdominal pain is recurrent and accompanied by vomiting. Larger case studies will be necessary to determine the true incidence of H. pylori in children with sickle cell disease and recurrent abdominal pain.

  6. Navigating recurrent abdominal pain through clinical clues, red flags, and initial testing.

    PubMed

    Noe, Joshua D; Li, B U K

    2009-05-01

    Recurrent abdominal pain is a common chronic complaint that presents to your office. The constant challenge is one of detecting those with organic disease from the majority who have a functional pain disorder including functional dyspepsia, irritable bowel syndrome, functional abdominal pain, and abdominal migraine. Beginning with a detailed history and physical exam, you can: 1) apply the symptom-based Rome III criteria to positively identify a functional disorder, and 2) filter these findings through the diagnostic clues and red flags that point toward specific organic disease and/or further testing. Once a functional diagnosis has been made or an organic disease is suspected, you can initiate a self-limited empiric therapeutic trial. With this diagnostic approach, you should feel confident navigating through the initial evaluation, management, and consultation referral for a child or adolescent with recurrent abdominal pain.

  7. Unindicated multiphase CT scans in non-traumatic abdominal emergencies for women of reproductive age: a significant source of unnecessary exposure.

    PubMed

    Giannitto, Caterina; Campoleoni, Mauro; Maccagnoni, Sara; Angileri, Alessio Salvatore; Grimaldi, Maria Carmela; Giannitto, Nino; De Piano, Francesca; Ancona, Eleonora; Biondetti, Pietro Raimondo; Esposito, Andrea Alessandro

    2018-03-01

    To determine the frequency of unindicated CT phases and the resultant excess of absorbed radiation doses to the uterus and ovaries in women of reproductive age who have undergone CT for non-traumatic abdomino-pelvic emergencies. We reviewed all abdomino-pelvic CT examinations in women of reproductive age (40 years or less), between 1 June 2012 and 31 January 2015. We evaluated the appropriateness of each CT phase on the basis of clinical indications, according to ACR appropriateness criteria and evidence-based data from the literature. The doses to uterus and ovaries for each phase were calculated with the CTEXPO software, taking into consideration the size-specific dose estimate (SSDE) after measuring the size of every single patient. The final cohort was composed of 76 female patients with an average age of 30 (from 19 to 40 years). In total, 197 CT phases were performed with an average of 2.6 phases per patient. Out of these, 93 (47%) were unindicated with an average of 1.2 inappropriate phases per patient. Unindicated scans were most frequent for appendicitis and unlocalized abdominal pain. The excesses of mean radiation doses to the uterus and ovaries due to unindicated phases were, respectively, of 38 and 33 mSv per patient. In our experience, unindicated additional CT phases were numerous with a significant excess radiation dose without an associated clinical benefit. This excess of radiation could have been avoided by widespread adoption of the ACR appropriateness criteria and evidence-based data from the literature.

  8. Emerging Techniques for Dose Optimization in Abdominal CT

    PubMed Central

    Platt, Joel F.; Goodsitt, Mitchell M.; Al-Hawary, Mahmoud M.; Maturen, Katherine E.; Wasnik, Ashish P.; Pandya, Amit

    2014-01-01

    Recent advances in computed tomographic (CT) scanning technique such as automated tube current modulation (ATCM), optimized x-ray tube voltage, and better use of iterative image reconstruction have allowed maintenance of good CT image quality with reduced radiation dose. ATCM varies the tube current during scanning to account for differences in patient attenuation, ensuring a more homogeneous image quality, although selection of the appropriate image quality parameter is essential for achieving optimal dose reduction. Reducing the x-ray tube voltage is best suited for evaluating iodinated structures, since the effective energy of the x-ray beam will be closer to the k-edge of iodine, resulting in a higher attenuation for the iodine. The optimal kilovoltage for a CT study should be chosen on the basis of imaging task and patient habitus. The aim of iterative image reconstruction is to identify factors that contribute to noise on CT images with use of statistical models of noise (statistical iterative reconstruction) and selective removal of noise to improve image quality. The degree of noise suppression achieved with statistical iterative reconstruction can be customized to minimize the effect of altered image quality on CT images. Unlike with statistical iterative reconstruction, model-based iterative reconstruction algorithms model both the statistical noise and the physical acquisition process, allowing CT to be performed with further reduction in radiation dose without an increase in image noise or loss of spatial resolution. Understanding these recently developed scanning techniques is essential for optimization of imaging protocols designed to achieve the desired image quality with a reduced dose. © RSNA, 2014 PMID:24428277

  9. Do we really rely on fast for decision-making in the management of blunt abdominal trauma?

    PubMed

    Carter, Jeffrey W; Falco, Mark H; Chopko, Michael S; Flynn, William J; Wiles Iii, Charles E; Guo, Weidun Alan

    2015-05-01

    The Focused Assessment with Sonography in Trauma examination (FAST) is currently taught and recommended in the ATLS(®), often as an addendum to the primary survey for patients with blunt abdominal trauma. Although it is non-invasive and rapidly performed at bedside, the utility of FAST in blunt abdominal trauma has been questioned. We designed this study to examine our hypothesis that FAST is not an efficacious screening tool for identifying intra-abdominal injuries. We performed a retrospective chart review of all patients with confirmatory diagnosis of blunt abdominal injuries with CT and/or laparotomy for a period of 1.5 years (from 7/2009 to 11/2010). FAST was performed by ED residents and considered positive when free intra-abdominal fluid was visualized. Abdominal CT, or exploratory laparotomy findings were used as confirmation of intra-abdominal injury. A total of 1671 blunt trauma patients were admitted to and evaluated in the Emergency Department during a 1½ year period and 146 patients were confirmed intra-abdominal injuries by CT and/or laparotomy. Intraoperative findings include injuries to the liver, spleen, kidneys, and bowels. In 114 hemodynamically stable patients, FAST was positive in 25 patients, with a sensitivity of 22%. In 32 hemodynamically unstable patients, FAST was positive in 9 patients, with a sensitivity of 28%. A free peritoneal fluid and splenic injury are associated with a positive FAST on univariate analysis, and are the independent predictors for a positive FAST on multiple logistic regression. FAST has a very low sensitivity in detecting blunt intraabdominal injury. In hemodynamically stable patients, a negative FAST without a CT may result in missed intra-abdominal injuries. In hemodynamically unstable blunt trauma patients, with clear physical findings on examination, the decision for exploratory laparotomy should not be distracted by a negative FAST. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Optimizing abdominal CT dose and image quality with respect to x-ray tube voltage

    NASA Astrophysics Data System (ADS)

    Huda, Walter; Ogden, Kent M.

    2004-05-01

    The objective of this study was to identify the x-ray tube voltage that results in optimum performance for abdominal CT imaging for a range of imaging tasks and patient sizes. Theoretical calculations were performed of the contrast to noise ratio (CNR) for disk shaped lesions of muscle, fat, bone and iodine embedded in a uniform water background. Lesion contrast was the mean Hounsfield Unit value at the effective photon energy, and image noise was determined from the total radiation intensity incident on the CT x-ray detector. Patient size ranging from young infants (10 kg) to oversized adults (120 kg), with CNR values obtained for x-ray tube voltages ranging from 80 to 140 kV. Patients of varying sizes were modeled as an equivalent cylinder of water, and the mean section dose (D) was determined for each selected x-ray tube kV value at a constant mAs. For each patient size and lesion type, we identified an optimal kV as the x-ray tube voltage that yields a maximum value of the figure of merit (CNR2/D). Increasing the x-ray tube voltage from 80 to 140 kV reduced lesion contrast by 11% for muscle, 21% for fat, 35% for bone and 52% for iodine, and these reductions were approximately independent of patient size. Increasing the x-ray tube voltage from 80 to 140 kV increased a muscle lesion CNR relative to a uniform water background by a factor of 2.6, with similar trends observed for fat (2.3), bone (1.9) and iodine (1.4). The improvement in lesion CNR with increasing x-ray tube voltage was highest for the largest sized patients. Increasing the x-ray tube voltage from 80 to 140 kV increased the patient dose by a factor of between 5.0 and 6.2 depending on the patient size. For small sized patients (10 and 30 kg) and muscle lesions, best performance is obtained at 80 kV; however, for adults (70 kg) and oversized adults (120 kg), the best performance would be obtained at 140 kV. Imaging fat lesions was best performed at 80 kV for all patients except for oversized adults

  11. TU-AB-BRA-01: Abdominal Synthetic CT Generation in Support of Liver SBRT Dose Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bredfeldt, JS; Liu, L; Feng, M

    2016-06-15

    Purpose: To demonstrate and validate a technique for generating MRI-derived synthetic CT volumes (MRCTs) in support of adaptive liver SBRT. Methods: Under IRB approval, ten hepatocellular carcinoma patients were scanned using a single MR sequence (T1 Dixon-VIBE), yielding inherently-registered water, fat, and T1-weighted images. Air-containing voxels were identified by intensity thresholding. The envelope of the anterior vertebral bodies was segmented from the fat image by fitting a shape model to vertebral body candidate voxels, then using level sets to expand the contour outward. Fuzzy-C-Means (FCM) was then used to classify each non-air voxel in the image as fat, water, bone,more » or marrow. Bone and marrow only were classified within the vertebral body envelope. The MRCT was created by integrating the product of the FCM class probability with the assigned class density for each voxel. The resulting MRCTs were deformably aligned with planning CTs and 2-ARC SBRT VMAT plans were optimized on the MRCT density maps. Fluence was copied onto the CT density grids and dose recalculated. Results: The MRCTs faithfully reproduced most of the features visible in the corresponding CT image volumes, with exceptions of ribs and posterior spinous processes. The liver, vertebral bodies, kidneys, spleen and cord all had median HU differences of less than 75 between MRCT and CT images. PTV D99% values had an average 0.2% difference (standard deviation: 0.46%) between calculations on MRCT and CT density grids. The maximum difference in dose to 0.1cc of the PTV was 0.25% (std:0.49%). OAR dose differences were similarly small (mean:0.03Gy, std:0.26Gy). The largest normal tissue complication percentage (NTCP) difference was 1.48% (mean:0.06%, std:0.54%). Conclusions: MRCTs from a single abdominal imaging sequence are promising for use in SBRT dose calculation. Future work will focus on extending models to better define bones in the upper abdomen. Supported by NIHR01EB016079 and NIH

  12. Reduced Radiation Dose with Model-based Iterative Reconstruction versus Standard Dose with Adaptive Statistical Iterative Reconstruction in Abdominal CT for Diagnosis of Acute Renal Colic.

    PubMed

    Fontarensky, Mikael; Alfidja, Agaïcha; Perignon, Renan; Schoenig, Arnaud; Perrier, Christophe; Mulliez, Aurélien; Guy, Laurent; Boyer, Louis

    2015-07-01

    To evaluate the accuracy of reduced-dose abdominal computed tomographic (CT) imaging by using a new generation model-based iterative reconstruction (MBIR) to diagnose acute renal colic compared with a standard-dose abdominal CT with 50% adaptive statistical iterative reconstruction (ASIR). This institutional review board-approved prospective study included 118 patients with symptoms of acute renal colic who underwent the following two successive CT examinations: standard-dose ASIR 50% and reduced-dose MBIR. Two radiologists independently reviewed both CT examinations for presence or absence of renal calculi, differential diagnoses, and associated abnormalities. The imaging findings, radiation dose estimates, and image quality of the two CT reconstruction methods were compared. Concordance was evaluated by κ coefficient, and descriptive statistics and t test were used for statistical analysis. Intraobserver correlation was 100% for the diagnosis of renal calculi (κ = 1). Renal calculus (τ = 98.7%; κ = 0.97) and obstructive upper urinary tract disease (τ = 98.16%; κ = 0.95) were detected, and differential or alternative diagnosis was performed (τ = 98.87% κ = 0.95). MBIR allowed a dose reduction of 84% versus standard-dose ASIR 50% (mean volume CT dose index, 1.7 mGy ± 0.8 [standard deviation] vs 10.9 mGy ± 4.6; mean size-specific dose estimate, 2.2 mGy ± 0.7 vs 13.7 mGy ± 3.9; P < .001) without a conspicuous deterioration in image quality (reduced-dose MBIR vs ASIR 50% mean scores, 3.83 ± 0.49 vs 3.92 ± 0.27, respectively; P = .32) or increase in noise (reduced-dose MBIR vs ASIR 50% mean, respectively, 18.36 HU ± 2.53 vs 17.40 HU ± 3.42). Its main drawback remains the long time required for reconstruction (mean, 40 minutes). A reduced-dose protocol with MBIR allowed a dose reduction of 84% without increasing noise and without an conspicuous deterioration in image quality in patients suspected of having renal colic.

  13. Outcome of Blunt Abdominal Traumas with Stable Hemodynamic and Positive FAST Findings.

    PubMed

    Behboodi, Firooz; Mohtasham-Amiri, Zahra; Masjedi, Navid; Shojaie, Reza; Sadri, Peyman

    2016-01-01

    Focused assessment with sonography for trauma (FAST) is a highly effective first screening tool for initial classification of abdominal trauma patients. The present study was designed to evaluate the outcome of patients with blunt abdominal trauma and positive FAST findings. The present prospective cross-sectional study was done on patients over 7 years old with normal abdominal examination, positive FAST findings, and available abdominopelvic computed tomography (CT) scan findings. The frequency of need for laparotomy as well as its probable risk factors were calculated. 180 patients were enrolled (mean age: 28.0 ± 11.5 years; 76.7% male). FAST findings were confirmed by abdominopelvic CT scan in only 124 (68.9%) cases. Finally, 12 (6.6%) patients needed laparotomy. Mean age of those in need of laparotomy was significantly higher than others (36.75 ± 11.37 versus 27.34 ± 11.37, p = 0.006). Higher grading of spleen (p = 0.001) and hepatic (p = 0.038) ruptures increased the probability of need for laparotomy. 68.9% of the positive FAST findings in patients with blunt abdominal trauma and stable hemodynamics was confirmed by abdominopelvic CT scan and only 6.6% needed laparotomy. Simultaneous presence of free fluid and air in the abdominal area, old age, and higher grading o solid organ injuries were factors that had a significant correlation with need for laparotomy.

  14. Pelvic Exam

    MedlinePlus

    ... of a routine physical exam to find possible signs of ovarian cysts, sexually transmitted infections, uterine fibroids or early-stage cancer. Pelvic exams are also commonly performed during pregnancy. There is a lot of debate among experts ...

  15. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up ofmore » 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.« less

  16. Challenges When Introducing Electronic Exam

    ERIC Educational Resources Information Center

    Kuikka, Matti; Kitola, Markus; Laakso, Mikko-Jussi

    2014-01-01

    Time pressures often necessitate the use of more efficient exam tools, such as electronic exams (e-exams), instead of traditional paper exams. However, teachers may face challenges when introducing e-exams in a higher education context. This paper describes what kinds of challenges teachers may face when introducing e-exams, based on experiences…

  17. Impact of HESI Specialty Exams: the ninth HESI Exit Exam validity study.

    PubMed

    Zweighaft, Elizabeth L

    2013-01-01

    Using an ex post facto, nonexperimental design, this, the ninth validity study of Elsevier's HESI Exit Exam (E(2)), reexamined the predictive accuracy of the E(2). The value of administering HESI Specialty Exams within the nursing curriculum in terms of E(2) scores was also investigated. The sample was composed of nursing students (N = 3,790) from 63 randomly selected schools-26 baccalaureate, 31 associate degree, and 6 diploma programs-throughout the United States who took the E(2) between September 2008 and August 2009. As in the previous 8 studies, the E(2) was found to be highly accurate (96.61%) in predicting success on the National Council Licensure Examination for Registered Nurses (NCLEX-RN). Findings also indicated that students who took one or more HESI Specialty Exams during their nursing curriculum had a significantly higher mean E(2) score (P ≤ .0001) than students who did not take HESI Specialty Exams during their nursing curriculum. Of the 8 HESI Specialty Exams investigated, scores on the Critical Care, Pediatrics, and Medical-Surgical specialty exams were most predictive of NCLEX-RN success. Schools of nursing that used HESI Specialty Exams as course final exams had a significantly higher mean E(2) score (P < .01) than schools that used the exams for remediation and practice. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Creating an outpatient center of excellence in CT.

    PubMed

    Itri, Jason N; Bakow, Eric; Woods, Jordan

    2014-12-01

    CT examinations represent a substantial portion of the workload for many radiology departments, and optimizing service delivery is a critical function to ensure customer satisfaction. This article describes how the Six Sigma methodology was used in the radiology department at a large academic hospital to improve the patient experience and increase CT capacity while reducing waste and improving staff satisfaction. The 5 distinct phases of Six Sigma are reviewed as they apply to our CT Center of Excellence project: define, measure, analyze, improve, and control. Process metrics used in this project include the percentage of outpatient CT exams started within 5 minutes of the scheduled appointment time, and the number of studies with protocols selected >48 hours before the CT exam is performed. Outcome metrics include monthly department expense per scan and CT Press Ganey "standard test and treatment" mean scores. An approach to developing interventions is described based on identifying critical sources of variation, ranking these by creating risk prioritization numbers, performing root cause analysis, and utilizing the failure mode and effects analysis tool to prioritize possible solutions. Finally, the key features of action plans and a control plan are reviewed. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    NASA Astrophysics Data System (ADS)

    Zhou, Yifang; Scott, Alexander, II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-10-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R^2  >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented.

  20. The Role of Computed Tomography in Blunt Abdominal Trauma.

    PubMed

    Karki, O B

    2015-01-01

    Blunt injury trauma is regularly encountered in the emergency department. Diagnostic tools that help in optimum management of blunt abdominal trauma include; Focussed Assessment Sonography for Trauma scan, Diagnostic peritoneal lavage and Computed Tomography scan. The aim of this study is to determine the validity of CT scan as an accurate diagnostic tool and its role in management of patients with blunt abdominal trauma. A prospective analysis of 80 patients of blunt abdomen trauma who were admitted in Manipal Teaching Hospital, Pokhara, Nepal within a span of 15 months was done. Demographic data, mechanism of trauma, management and outcomes were studied. Organ injuries were graded using the Organ Injury Scale guidelines. Most of the patients in our study were in the age group of 21-40 years with an M: F ratio of 2.3:1. Road traffic accident (47.5%) was the most common mechanism of injury. Spleen (27.5%) was the commonest organ injured. CT scan was superior to FAST scan and had sensitivity of 97.3% specificity 75% positive predictive value 98.6%. FAST scan had sensitivity of 78.9%, specificity 50%, positive predictive value 96% with p- value of 0.0034. 81% of patients were conservatively managed. In conjunction with close clinical monitoring, CT scan is reliable in the evaluation and management of blunt abdominal trauma patients. Our study also shows CT as a superior diagnostic modality compared to FAST scan.

  1. Radiation Dose Reduction via Sinogram Affirmed Iterative Reconstruction and Automatic Tube Voltage Modulation (CARE kV) in Abdominal CT

    PubMed Central

    Shin, Hyun Joo; Lee, Young Han; Choi, Jin-Young; Park, Mi-Suk; Kim, Myeong-Jin; Kim, Ki Whang

    2013-01-01

    Objective To evaluate the feasibility of sinogram-affirmed iterative reconstruction (SAFIRE) and automated kV modulation (CARE kV) in reducing radiation dose without increasing image noise for abdominal CT examination. Materials and Methods This retrospective study included 77 patients who received CT imaging with an application of CARE kV with or without SAFIRE and who had comparable previous CT images obtained without CARE kV or SAFIRE, using the standard dose (i.e., reference mAs of 240) on an identical CT scanner and reconstructed with filtered back projection (FBP) within 1 year. Patients were divided into two groups: group A (33 patients, CT scanned with CARE kV); and group B (44 patients, scanned after reducing the reference mAs from 240 to 170 and applying both CARE kV and SAFIRE). CT number, image noise for four organs and radiation dose were compared among the two groups. Results Image noise increased after CARE kV application (p < 0.001) and significantly decreased as SAFIRE strength increased (p < 0.001). Image noise with reduced-mAs scan (170 mAs) in group B became similar to that of standard-dose FBP images after applying CARE kV and SAFIRE strengths of 3 or 4 when measured in the aorta, liver or muscle (p ≥ 0.108). Effective doses decreased by 19.4% and 41.3% for groups A and B, respectively (all, p < 0.001) after application of CARE kV with or without SAFIRE. Conclusion Combining CARE kV, reduction of mAs from 240 to 170 mAs and noise reduction by applying SAFIRE strength 3 or 4 reduced the radiation dose by 41.3% without increasing image noise compared with the standard-dose FBP images. PMID:24265563

  2. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    PubMed

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  3. The Accuracy of Urinalysis in Predicting Intra-Abdominal Injury Following Blunt Traumas.

    PubMed

    Sabzghabaei, Anita; Shojaee, Majid; Safari, Saeed; Hatamabadi, Hamid Reza; Shirvani, Reza

    2016-01-01

    In cases of blunt abdominal traumas, predicting the possible intra-abdominal injuries is still a challenge for the physicians involved with these patients. Therefore, this study was designed, to evaluate the accuracy of urinalysis in predicting intra-abdominal injuries. Patients aged 15 to 65 years with blunt abdominal trauma who were admitted to emergency departments were enrolled. Abdominopelvic computed tomography (CT) scan with intravenous contrast and urinalysis were requested for all the included patients. Demographic data, trauma mechanism, the results of urinalysis, and the results of abdominopelvic CT scan were gathered. Finally, the correlation between the results of abdominopelvic CT scan, and urinalysis was determined. Urinalysis was considered positive in case of at least one positive value in gross appearance, blood in dipstick, or red blood cell count. 325 patients with blunt abdominal trauma were admitted to the emergency departments (83% male with the mean age of 32.63±17.48 years). Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of urinalysis, were 77.9% (95% CI: 69.6-84.4), 58.5% (95% CI: 51.2-65.5), 56% (95% CI: 48.5-63.3), 79.6% (95% CI: 71.8-85.7), 1.27% (95% CI: 1.30-1.57), and 0.25% (95% CI: 0.18-0.36), respectively. The diagnostic value of urinalysis in prediction of blunt traumatic intra-abdominal injuries is low and it seems that it should be considered as an adjuvant diagnostic tool, in conjunction with other sources such as clinical findings and imaging.

  4. Recurrent severe abdominal pain in the pediatric patient.

    PubMed

    Homme, James L; Foster, Ashley A

    2014-05-01

    Ureteropelvic junction obstruction (UPJO) is a blockage occurring at the junction of the ureter and the renal pelvis. Pediatric patients with UPJO pose a diagnostic challenge when they present to the emergency department (ED) with severe recurrent abdominal pain if there is not a level of suspicion for this condition. Our aim was to review presentation of UPJO to the ED, methods of diagnosis, and treatment of this common but often overlooked condition. We report on 2 patients, a 9-year-old and 3-year-old, who had multiple presentations to health care providers and the ED with intermittent and recurrent abdominal pain. Subsequent testing, including ultrasound (US) and computed tomography (CT) with diuretic-recreated symptoms, revealed UPJO. Open pyeloplasty was performed, resulting in complete resolution of symptoms. UPJO is an important diagnosis to consider when patients present to the ED with recurrent abdominal pain. US can be helpful in suspecting the diagnosis, but often CT, magnetic resonance urography, or diuretic scintigraphy is required for confirmation. Diuretics can be used to aid diagnostic testing by reproducing abdominal pain at the time of imaging. Referral to a urologist for open pyeloplasty is definitive treatment for this condition. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom

    NASA Astrophysics Data System (ADS)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-06-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  6. The relevance of image quality indices for dose optimization in abdominal multi-detector row CT in children: experimental assessment with pediatric phantoms

    NASA Astrophysics Data System (ADS)

    Brisse, H. J.; Brenot, J.; Pierrat, N.; Gaboriaud, G.; Savignoni, A.; DeRycke, Y.; Neuenschwander, S.; Aubert, B.; Rosenwald, J.-C.

    2009-04-01

    This study assessed and compared various image quality indices in order to manage the dose of pediatric abdominal MDCT protocols and to provide guidance on dose reduction. PMMA phantoms representing average body diameters at birth, 1 year, 5 years, 10 years and 15 years of age were scanned in a four-channel MDCT with a standard pediatric abdominal CT protocol. Image noise (SD, standard deviation of CT number), noise derivative (ND, derivative of the function of noise with respect to dose) and contrast-to-noise ratio (CNR) were measured. The 'relative' low-contrast detectability (rLCD) was introduced as a new quantity to adjust LCD to the various phantom diameters on the basis of the LCD1% assessed in a Catphan® phantom and a constant central absorbed dose. The required variations of CTDIvol16 with respect to phantom size were analyzed in order to maintain each image quality index constant. The use of a fixed SD or CNR level leads to major dose ratios between extreme patient sizes (factor 22.7 to 44 for SD, 31.7 to 51.5 for CNR2.8%), whereas fixed ND and rLCD result in acceptable dose ratios ranging between factors of 2.9 and 3.9 between extreme phantom diameters. For a 5-9 mm rLCD1%, adjusted ND values range between -0.84 and -0.11 HU mGy-1. Our data provide guidance on dose reduction on the basis of patient dimensions and the required rLCD (e.g., to get a constant 7 mm rLCD1% for abdominal diameters of 10, 13, 16, 20 and 25 cm, tube current-time product should be adjusted in order to obtain CTDIvol16 values of 6.2, 7.2, 8.8, 11.6 and 17.7 mGy, respectively).

  7. Spontaneous rectus sheath hematoma: The utility of CT angiography.

    PubMed

    Pierro, Antonio; Cilla, Savino; Modugno, Pietro; Centritto, Enrico Maria; De Filippo, Carlo Maria; Sallustio, Giuseppina

    2018-04-01

    We described the utility of computed tomography (CT) angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization.

  8. Predominance of Abdominal Visceral Adipose Tissue Reflects the Presence of Aortic Valve Calcification.

    PubMed

    Oikawa, Masayoshi; Owada, Takashi; Yamauchi, Hiroyuki; Misaka, Tomofumi; Machii, Hirofumi; Yamaki, Takayoshi; Sugimoto, Koichi; Kunii, Hiroyuki; Nakazato, Kazuhiko; Suzuki, Hitoshi; Saitoh, Shu-Ichi; Takeishi, Yasuchika

    2016-01-01

    Background. Aortic valve calcification (AVC) is a common feature of aging and is related to coronary artery disease. Although abdominal visceral adipose tissue (VAT) plays fundamental roles in coronary artery disease, the relationship between abdominal VAT and AVC is not fully understood. Methods. We investigated 259 patients who underwent cardiac and abdominal computed tomography (CT). AVC was defined as calcified lesion on the aortic valve by CT. %abdominal VAT was calculated as abdominal VAT area/total adipose tissue area. Results. AVC was detected in 75 patients, and these patients showed higher %abdominal VAT (44% versus 38%, p < 0.05) compared to those without AVC. When the cutoff value of %abdominal VAT was set at 40.9%, the area under the curve to diagnose AVC was 0.626. Multivariable logistic regression analysis showed that age (OR 1.120, 95% CI 1.078-1.168, p < 0.01), diabetes (OR 2.587, 95% CI 1.323-5.130, p < 0.01), and %abdominal VAT (OR 1.032, 95% CI 1.003-1.065, p < 0.05) were independent risk factors for AVC. The net reclassification improvement value for detecting AVC was increased when %abdominal VAT was added to the model: 0.5093 (95% CI 0.2489-0.7697, p < 0.01). Conclusion. We determined that predominance of VAT is associated with AVC.

  9. Predominance of Abdominal Visceral Adipose Tissue Reflects the Presence of Aortic Valve Calcification

    PubMed Central

    Oikawa, Masayoshi; Owada, Takashi; Yamauchi, Hiroyuki; Misaka, Tomofumi; Machii, Hirofumi; Yamaki, Takayoshi; Sugimoto, Koichi; Kunii, Hiroyuki; Nakazato, Kazuhiko; Suzuki, Hitoshi; Saitoh, Shu-ichi; Takeishi, Yasuchika

    2016-01-01

    Background. Aortic valve calcification (AVC) is a common feature of aging and is related to coronary artery disease. Although abdominal visceral adipose tissue (VAT) plays fundamental roles in coronary artery disease, the relationship between abdominal VAT and AVC is not fully understood. Methods. We investigated 259 patients who underwent cardiac and abdominal computed tomography (CT). AVC was defined as calcified lesion on the aortic valve by CT. %abdominal VAT was calculated as abdominal VAT area/total adipose tissue area. Results. AVC was detected in 75 patients, and these patients showed higher %abdominal VAT (44% versus 38%, p < 0.05) compared to those without AVC. When the cutoff value of %abdominal VAT was set at 40.9%, the area under the curve to diagnose AVC was 0.626. Multivariable logistic regression analysis showed that age (OR 1.120, 95% CI 1.078–1.168, p < 0.01), diabetes (OR 2.587, 95% CI 1.323–5.130, p < 0.01), and %abdominal VAT (OR 1.032, 95% CI 1.003–1.065, p < 0.05) were independent risk factors for AVC. The net reclassification improvement value for detecting AVC was increased when %abdominal VAT was added to the model: 0.5093 (95% CI 0.2489–0.7697, p < 0.01). Conclusion. We determined that predominance of VAT is associated with AVC. PMID:26904670

  10. An assessment of the iPad 2 as a CT teleradiology tool using brain CT with subtle intracranial hemorrhage under conventional illumination.

    PubMed

    Park, Joon Bum; Choi, Hyuk Joong; Lee, Jeong Hun; Kang, Bo Seung

    2013-08-01

    We examined the potential of the iPad 2 as a teleradiologic tool for evaluating brain computed tomography (CT) with subtle hemorrhage in the conventional lighting conditions which are common situations in the remote CT reading. The comparison of the clinician's performance was undertaken through detecting hemorrhage by the iPad 2 and the clinical liquid crystal display (LCD) monitor. We selected 100 brain CT exams performed for head trauma or headache. Fifty had subtle radiological signs of intracranial hemorrhage (ICH), while the other 50 showed no significant abnormality. Five emergency medicine physicians reviewed these brain CT scans using the iPad 2 and the LCD monitor, scoring the probability of ICH on each exam on a five-point scale. Result showed high sensitivities and specificities in both devices. We generated receiver operating characteristic curves and calculated the average area under the curve of the iPad 2 and the LCD (0.935 and 0.900). Using the iPad 2 and reliable internet connectivity, clinicians can provide remote evaluation of brain CT with subtle hemorrhage under suboptimal viewing condition. Considering the distinct advantages of the iPad 2, the popular out-of-hospital use of mobile CT teleradiology would be anticipated soon.

  11. Calcification detection of abdominal aorta in CT images and 3D visualization in VR devices.

    PubMed

    Garcia-Berna, Jose A; Sanchez-Gomez, Juan M; Hermanns, Judith; Garcia-Mateos, Gines; Fernandez-Aleman, Jose L

    2016-08-01

    Automatic calcification detection in abdominal aorta consists of a set of computer vision techniques to quantify the amount of calcium that is found around this artery. Knowing that information, it is possible to perform statistical studies that relate vascular diseases with the presence of calcium in these structures. To facilitate the detection in CT images, a contrast is usually injected into the circulatory system of the patients to distinguish the aorta from other body tissues and organs. This contrast increases the absorption of X-rays by human blood, making it easier the measurement of calcifications. Based on this idea, a new system capable of detecting and tracking the aorta artery has been developed with an estimation of the calcium found surrounding the aorta. Besides, the system is complemented with a 3D visualization mode of the image set which is designed for the new generation of immersive VR devices.

  12. Emergency ultrasound-based algorithms for diagnosing blunt abdominal trauma.

    PubMed

    Stengel, Dirk; Bauwens, Kai; Rademacher, Grit; Ekkernkamp, Axel; Güthoff, Claas

    2013-07-31

    Ultrasonography is regarded as the tool of choice for early diagnostic investigations in patients with suspected blunt abdominal trauma. Although its sensitivity is too low for definite exclusion of abdominal organ injury, proponents of ultrasound argue that ultrasound-based clinical pathways enhance the speed of primary trauma assessment, reduce the number of computed tomography scans and cut costs. To assess the effects of trauma algorithms that include ultrasound examinations in patients with suspected blunt abdominal trauma. We searched the Cochrane Injuries Group's Specialised Register, CENTRAL (The Cochrane Library), MEDLINE (OvidSP), EMBASE (OvidSP), CINAHL (EBSCO), publishers' databases, controlled trials registers and the Internet. Bibliographies of identified articles and conference abstracts were searched for further elligible studies. Trial authors were contacted for further information and individual patient data. The searches were updated in February 2013. randomised controlled trials (RCTs) and quasi-randomised trials (qRCTs). patients with blunt torso, abdominal or multiple trauma undergoing diagnostic investigations for abdominal organ injury. diagnostic algorithms comprising emergency ultrasonography (US). diagnostic algorithms without ultrasound examinations (for example, primary computed tomography [CT] or diagnostic peritoneal lavage [DPL]). mortality, use of CT and DPL, cost-effectiveness, laparotomy and negative laparotomy rates, delayed diagnoses, and quality of life. Two authors independently selected trials for inclusion, assessed methodological quality and extracted data. Where possible, data were pooled and relative risks (RRs), risk differences (RDs) and weighted mean differences, each with 95% confidence intervals (CIs), were calculated by fixed- or random-effects modelling, as appropriate. We identified four studies meeting our inclusion criteria. Overall, trials were of moderate methodological quality. Few trial authors responded to

  13. Estimating Radiation Dose Metrics for Patients Undergoing Tube Current Modulation CT Scans

    NASA Astrophysics Data System (ADS)

    McMillan, Kyle Lorin

    Computed tomography (CT) has long been a powerful tool in the diagnosis of disease, identification of tumors and guidance of interventional procedures. With CT examinations comes the concern of radiation exposure and the associated risks. In order to properly understand those risks on a patient-specific level, organ dose must be quantified for each CT scan. Some of the most widely used organ dose estimates are derived from fixed tube current (FTC) scans of a standard sized idealized patient model. However, in current clinical practice, patient size varies from neonates weighing just a few kg to morbidly obese patients weighing over 200 kg, and nearly all CT exams are performed with tube current modulation (TCM), a scanning technique that adjusts scanner output according to changes in patient attenuation. Methods to account for TCM in CT organ dose estimates have been previously demonstrated, but these methods are limited in scope and/or restricted to idealized TCM profiles that are not based on physical observations and not scanner specific (e.g. don't account for tube limits, scanner-specific effects, etc.). The goal of this work was to develop methods to estimate organ doses to patients undergoing CT scans that take into account both the patient size as well as the effects of TCM. This work started with the development and validation of methods to estimate scanner-specific TCM schemes for any voxelized patient model. An approach was developed to generate estimated TCM schemes that match actual TCM schemes that would have been acquired on the scanner for any patient model. Using this approach, TCM schemes were then generated for a variety of body CT protocols for a set of reference voxelized phantoms for which TCM information does not currently exist. These are whole body patient models representing a variety of sizes, ages and genders that have all radiosensitive organs identified. TCM schemes for these models facilitated Monte Carlo-based estimates of fully

  14. Radiology metrics for safe use and regulatory compliance with CT imaging

    NASA Astrophysics Data System (ADS)

    Paden, Robert; Pavlicek, William

    2018-03-01

    The MACRA Act creates a Merit-Based Payment System, with monitoring patient exposure from CT providing one possible quality metric for meeting merit requirements. Quality metrics are also required by The Joint Commission, ACR, and CMS as facilities are tasked to perform reviews of CT irradiation events outside of expected ranges, review protocols for appropriateness, and validate parameters for low dose lung cancer screening. In order to efficiently collect and analyze irradiation events and associated DICOM tags, all clinical CT devices were DICOM connected to a parser which extracted dose related information for storage into a database. Dose data from every exam is compared to the appropriate external standard exam type. AAPM recommended CTDIvol values for head and torso, adult and pediatrics, coronary and perfusion exams are used for this study. CT doses outside the expected range were automatically formatted into a report for analysis and review documentation. CT Technologist textual content, the reason for proceeding with an irradiation above the recommended threshold, is captured for inclusion in the follow up reviews by physics staff. The use of a knowledge based approach in labeling individual protocol and device settings is a practical solution resulting in efficiency of analysis and review. Manual methods would require approximately 150 person-hours for our facility, exclusive of travel time and independent of device availability. An efficiency of 89% time savings occurs through use of this informatics tool including a low dose CT comparison review and low dose lung cancer screening requirements set forth by CMS.

  15. Anatomic characteristics of ruptured abdominal aortic aneurysm on conventional CT scans: Implications for rupture risk.

    PubMed

    Fillinger, Mark F; Racusin, Jessica; Baker, Robert K; Cronenwett, Jack L; Teutelink, Arno; Schermerhorn, Marc L; Zwolak, Robert M; Powell, Richard J; Walsh, Daniel B; Rzucidlo, Eva M

    2004-06-01

    The purpose of this study was to analyze anatomic characteristics of patients with ruptured abdominal aortic aneurysms (AAAs), with conventional two-dimensional computed tomography (CT), including comparison with control subjects matched for age, gender, and size. Records were reviewed to identify all CT scans obtained at Dartmouth-Hitchcock Medical Center or referring hospitals before emergency AAA repair performed because of rupture or acute severe pain (RUP group). CT scans obtained before elective AAA repair (ELEC group) were reviewed for age and gender match with patients in the RUP group. More than 40 variables were measured on each CT scan. Aneurysm diameter matching was achieved by consecutively deleting the largest RUP scan and the smallest ELEC scan to prevent bias. CT scans were analyzed for 259 patients with AAAs: 122 RUP and 137 ELEC. Patients were well matched for age, gender, and other demographic variables or risk factors. Maximum AAA diameter was significantly different in comparisons of all patients (RUP, 6.5 +/- 2 cm vs ELEC, 5.6 +/- 1 cm; P <.0001), and mean diameter of ruptured AAAs was 5 mm smaller in female patients (6.1 +/- 2 cm vs 6.6 +/- 2 cm; P =.007). Two hundred patients were matched for diameter, gender, and age (100 from each group; maximum AAA diameter, 6.0 +/- 1 cm vs 6.0 +/- 1 cm). Analysis of diameter-matched AAAs indicated that most variables were statistically similar in the two groups, including infrarenal neck length (17 +/- 1 mm vs 19 +/- 1 mm; P =.3), maximum thrombus thickness (25 +/- 1 mm vs 23 +/- 1 mm, P =.4), and indices of body habitus, such as [(maximum AAA diameter)/(normal suprarenal aorta diameter)] or [(maximum AAA diameter)/(L3 transverse diameter)]. Multivariate analysis controlling for gender indicated that the most significant variables for rupture were aortic tortuosity (odds ratio [OR] 3.3, indicating greater risk with no or mild tortuosity), diameter asymmetry (OR, 3.2 for a 1-cm difference in major

  16. Abdominal actinomycosis masquerading as an omental tumor in a 12-year-old female.

    PubMed

    Hirayama, Yutaka; Iinuma, Yasushi; Hashizume, Naoki; Yoshida, Motomu; Iida, Hisataka; Shibuya, Hiroyuki; Naito, Shinichi; Nitta, Koju

    2013-02-01

    We herein report a case of abdominal actinomycosis in a 12-year-old girl in whom an omental primary tumor was suspected before surgery. The patient began to experience intermittent lower left abdominal pain. Abdominal computed tomography (CT) scans were inconclusive at this time, but 6 months later, CT and magnetic resonance imaging (MRI) examinations showed a 7-cm, tumor-like lesion in the left abdominal cavity; malignancy could not be ruled out. The tumor, which originated in the omentum and adhered strongly to the left abdominal wall, was resected along with approximately 90 % of the omentum, the peritoneum in contact with the mass, and the posterior layer of the rectus abdominal sheath, under suspicion of a malignant tumor. However, omental actinomycosis was the final pathological diagnosis. The patient's antibiotic treatment was changed to a penicillin-series oral antibiotic to prevent recurrence of the actinomycosis. The patient was discharged from our hospital 16 days after the first surgery, but she developed three episodes of ileus; the first two required surgery. The patient has had no further recurrences of actinomycosis or postoperative ileus 20 months after discharge.

  17. Sensitivity and Specificity of Emergency Physicians and Trainees for Identifying Internally Concealed Drug Packages on Abdominal Computed Tomography Scan: Do Lung Windows Improve Accuracy?

    PubMed

    Asha, Stephen Edward; Cooke, Andrew

    2015-09-01

    Suspected body packers may be brought to emergency departments (EDs) close to international airports for abdominal computed tomography (CT) scanning. Senior emergency clinicians may be asked to interpret these CT scans. Missing concealed drug packages have important clinical and forensic implications. The accuracy of emergency clinician interpretation of abdominal CT scans for concealed drugs is not known. Limited evidence suggests that accuracy for identification of concealed packages can be increased by viewing CT images on "lung window" settings. To determine the accuracy of senior emergency clinicians in interpreting abdominal CT scans for concealed drugs, and to determine if this accuracy was improved by viewing scans on both abdominal and lung window settings. Emergency clinicians blinded to all patient identifiers and the radiology report interpreted CT scans of suspected body packers using standard abdominal window settings and then with the addition of lung window settings. The reference standard was the radiologist's report. Fifty-five emergency clinicians reported 235 CT scans. The sensitivity, specificity, and accuracy of interpretation using abdominal windows was 89.9% (95% confidence interval [CI] 83.0-94.7), 81.9% (95% CI 73.7-88.4), and 86.0% (95% CI 81.5-90.4), respectively, and with both window settings was 94.1% (95% CI 88.3-97.6), 76.7% (95% CI 68.0-84.1), 85.5% (95% CI 81.0-90.0), respectively. Diagnostic accuracy was similar regardless of the clinician's experience. Interrater reliability was moderate (kappa 0.46). The accuracy of interpretation of abdominal CT scans performed for the purpose of detecting concealed drug packages by emergency clinicians is not high enough to safely discharge these patients from the ED. The use of lung windows improved sensitivity, but at the expense of specificity. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  18. Optimizing working space in laparoscopy: CT measurement of the effect of pre-stretching of the abdominal wall in a porcine model.

    PubMed

    Vlot, John; Wijnen, René; Stolker, Robert Jan; Bax, Klaas N

    2014-03-01

    Determinants of working space in minimal access surgery have not been well studied. Using computed tomography (CT) to measure volumes and linear dimensions, we are studying the effect of a number of determinants of CO2 working space in a porcine laparoscopy model. Here we report the effects of pre-stretching of the abdominal wall. Earlier we had noted an increase in CO2 pneumoperitoneum volume at repeat insufflation with an intra-abdominal pressure (IAP) of 5 mmHg after previous stepwise insufflation up to an IAP of 15 mmHg. We reviewed the data of this serendipity group; data of 16 pigs were available. In a new group of eight pigs, we also explored this effect at repeat IAPs of 10 and 15 mmHg. Volumes and linear dimensions of the CO2 pneumoperitoneum were measured on reconstructed CT images and compared between the initial and repeat insufflation runs. Previous stepwise insufflation of the abdomen with CO2 up to 15 mmHg significantly (p < 0.01) increased subsequent working-space volume at a repeat IAP of 5 mmHg by 21 %, 7 % at a repeat IAP of 10 mmHg and 3 % at a repeat IAP of 15 mmHg. The external anteroposterior diameter significantly (p < 0.01) increased by 0.5 cm (14 %) at repeat 5 mmHg. Other linear dimensions showed a much smaller change. There was no statistically significant correlation between the duration of the insufflation run and the volume increase after pre-stretching at all IAP levels. Pre-stretching of the abdominal wall allows for the same surgical-field exposure at lower IAPs, reducing the negative effects of prolonged high-pressure CO2 pneumoperitoneum on the cardiorespiratory system and microcirculation. Pre-stretching has important scientific consequences in studies addressing ways of increasing working space in that its effect may confound the possible effects of other interventions aimed at increasing working space.

  19. Texture analysis improves level set segmentation of the anterior abdominal wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Zhoubing; Allen, Wade M.; Baucom, Rebeccah B.

    2013-12-15

    Purpose: The treatment of ventral hernias (VH) has been a challenging problem for medical care. Repair of these hernias is fraught with failure; recurrence rates ranging from 24% to 43% have been reported, even with the use of biocompatible mesh. Currently, computed tomography (CT) is used to guide intervention through expert, but qualitative, clinical judgments, notably, quantitative metrics based on image-processing are not used. The authors propose that image segmentation methods to capture the three-dimensional structure of the abdominal wall and its abnormalities will provide a foundation on which to measure geometric properties of hernias and surrounding tissues and, therefore,more » to optimize intervention.Methods: In this study with 20 clinically acquired CT scans on postoperative patients, the authors demonstrated a novel approach to geometric classification of the abdominal. The authors’ approach uses a texture analysis based on Gabor filters to extract feature vectors and follows a fuzzy c-means clustering method to estimate voxelwise probability memberships for eight clusters. The memberships estimated from the texture analysis are helpful to identify anatomical structures with inhomogeneous intensities. The membership was used to guide the level set evolution, as well as to derive an initial start close to the abdominal wall.Results: Segmentation results on abdominal walls were both quantitatively and qualitatively validated with surface errors based on manually labeled ground truth. Using texture, mean surface errors for the outer surface of the abdominal wall were less than 2 mm, with 91% of the outer surface less than 5 mm away from the manual tracings; errors were significantly greater (2–5 mm) for methods that did not use the texture.Conclusions: The authors’ approach establishes a baseline for characterizing the abdominal wall for improving VH care. Inherent texture patterns in CT scans are helpful to the tissue classification, and

  20. SU-E-P-49: Evaluation of Image Quality and Radiation Dose of Various Unenhanced Head CT Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, L; Khan, M; Alapati, K

    2015-06-15

    Purpose: To evaluate the diagnostic value of various unenhanced head CT protocols and predicate acceptable radiation dose level for head CT exam. Methods: Our retrospective analysis included 3 groups, 20 patients per group, who underwent clinical routine unenhanced adult head CT examination. All exams were performed axially with 120 kVp. Three protocols, 380 mAs without iterative reconstruction and automAs, 340 mAs with iterative reconstruction without automAs, 340 mAs with iterative reconstruction and automAs, were applied on each group patients respectively. The images were reconstructed with H30, J30 for brain window and H60, J70 for bone window. Images acquired with threemore » protocols were randomized and blindly reviewed by three radiologists. A 5 point scale was used to rate each exam The percentage of exam score above 3 and average scores of each protocol were calculated for each reviewer and tissue types. Results: For protocols without automAs, the average scores of bone window with iterative reconstruction were higher than those without iterative reconstruction for each reviewer although the radiation dose was 10 percentage lower. 100 percentage exams were scored 3 or higher and the average scores were above 4 for both brain and bone reconstructions. The CTDIvols are 64.4 and 57.8 mGy of 380 and 340 mAs, respectively. With automAs, the radiation dose varied with head size, resulting in 47.5 mGy average CTDIvol between 39.5 and 56.5 mGy. 93 and 98 percentage exams were scored great than 3 for brain and bone windows, respectively. The diagnostic confidence level and image quality of exams with AutomAs were less than those without AutomAs for each reviewer. Conclusion: According to these results, the mAs was reduced to 300 with automAs OFF for head CT exam. The radiation dose was 20 percentage lower than the original protocol and the CTDIvol was reduced to 51.2 mGy.« less

  1. Patient doses from CT examinations in Turkey.

    PubMed

    Ataç, Gökçe Kaan; Parmaksız, Aydın; İnal, Tolga; Bulur, Emine; Bulgurlu, Figen; Öncü, Tolga; Gündoğdu, Sadi

    2015-01-01

    We aimed to establish the first diagnostic reference levels (DRLs) for computed tomography (CT) examinations in adult and pediatric patients in Turkey and compare these with international DRLs. CT performance information and examination parameters (for head, chest, high-resolution CT of the chest [HRCT-chest], abdominal, and pelvic protocols) from 1607 hospitals were collected via a survey. Dose length products and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIvol). The median number of protocols reported from the 167 responding hospitals (10% response rate) was 102 across five different age groups. Third quartile CTDIvol values for adult pelvic and all pediatric body protocols were higher than the European Commission standards but were comparable to studies conducted in other countries. The radiation dose indicators for adult patients were similar to those reported in the literature, except for those associated with head protocols. CT protocol optimization is necessary for adult head and pediatric chest, HRCT-chest, abdominal, and pelvic protocols. The findings from this study are recommended for use as national DRLs in Turkey.

  2. Segmentation of images of abdominal organs.

    PubMed

    Wu, Jie; Kamath, Markad V; Noseworthy, Michael D; Boylan, Colm; Poehlman, Skip

    2008-01-01

    Abdominal organ segmentation, which is, the delineation of organ areas in the abdomen, plays an important role in the process of radiological evaluation. Attempts to automate segmentation of abdominal organs will aid radiologists who are required to view thousands of images daily. This review outlines the current state-of-the-art semi-automated and automated methods used to segment abdominal organ regions from computed tomography (CT), magnetic resonance imaging (MEI), and ultrasound images. Segmentation methods generally fall into three categories: pixel based, region based and boundary tracing. While pixel-based methods classify each individual pixel, region-based methods identify regions with similar properties. Boundary tracing is accomplished by a model of the image boundary. This paper evaluates the effectiveness of the above algorithms with an emphasis on their advantages and disadvantages for abdominal organ segmentation. Several evaluation metrics that compare machine-based segmentation with that of an expert (radiologist) are identified and examined. Finally, features based on intensity as well as the texture of a small region around a pixel are explored. This review concludes with a discussion of possible future trends for abdominal organ segmentation.

  3. CT of schistosomal calcification of the intestine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fataar, S.; Bassiony, H.; Satyanath, S.

    1985-01-01

    The spectrum of schistosomal colonic calcification on abdominal radiographs has been described. The appearance on computed tomography (CT) is equally distinctive and occurs with varying degrees of genitourinary calcification. The authors have experience in three cases with the appearance on CT of intestinal calcification due to schistosomiasis.

  4. Digital rectal exam

    MedlinePlus

    Skip navigation U.S. National Library of Medicine The navigation menu has been collapsed. Menu ... exam URL of this page: //medlineplus.gov/ency/article/007069.htm Digital rectal exam To use the sharing features ...

  5. Automatic liver segmentation from abdominal CT volumes using graph cuts and border marching.

    PubMed

    Liao, Miao; Zhao, Yu-Qian; Liu, Xi-Yao; Zeng, Ye-Zhan; Zou, Bei-Ji; Wang, Xiao-Fang; Shih, Frank Y

    2017-05-01

    Identifying liver regions from abdominal computed tomography (CT) volumes is an important task for computer-aided liver disease diagnosis and surgical planning. This paper presents a fully automatic method for liver segmentation from CT volumes based on graph cuts and border marching. An initial slice is segmented by density peak clustering. Based on pixel- and patch-wise features, an intensity model and a PCA-based regional appearance model are developed to enhance the contrast between liver and background. Then, these models as well as the location constraint estimated iteratively are integrated into graph cuts in order to segment the liver in each slice automatically. Finally, a vessel compensation method based on the border marching is used to increase the segmentation accuracy. Experiments are conducted on a clinical data set we created and also on the MICCAI2007 Grand Challenge liver data. The results show that the proposed intensity, appearance models, and the location constraint are significantly effective for liver recognition, and the undersegmented vessels can be compensated by the border marching based method. The segmentation performances in terms of VOE, RVD, ASD, RMSD, and MSD as well as the average running time achieved by our method on the SLIVER07 public database are 5.8 ± 3.2%, -0.1 ± 4.1%, 1.0 ± 0.5mm, 2.0 ± 1.2mm, 21.2 ± 9.3mm, and 4.7 minutes, respectively, which are superior to those of existing methods. The proposed method does not require time-consuming training process and statistical model construction, and is capable of dealing with complicated shapes and intensity variations successfully. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    PubMed

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  7. Comparison of spirometry and abdominal height as four-dimensional computed tomography metrics in lung

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu Wei; Low, Daniel A.; Parikh, Parag J.

    2005-07-15

    An important consideration in four-dimensional CT scanning is the selection of a breathing metric for sorting the CT data and modeling internal motion. This study compared two noninvasive breathing metrics, spirometry and abdominal height, against internal air content, used as a surrogate for internal motion. Both metrics were shown to be accurate, but the spirometry showed a stronger and more reproducible relationship than the abdominal height in the lung. The abdominal height was known to be affected by sensor placement and patient positioning while the spirometer exhibited signal drift. By combining these two, a normalization of the drift-free metric tomore » tidal volume may be generated and the overall metric precision may be improved.« less

  8. Use of the initial trauma CT scan to aid in diagnosis of open pelvic fractures.

    PubMed

    Scolaro, John A; Wilson, David J; Routt, Milton Lee Chip; Firoozabadi, Reza

    2015-10-01

    Open pelvic disruptions represent high-energy injuries. The prompt identification and management of these injuries decreases their associated morbidity and mortality. Computed tomography (CT) scans are routinely obtained in the initial evaluation of patients with pelvic injuries. The purpose of this study is to identify the incidence and source of air densities noted on computed tomography (CT) scans of the abdominal and pelvic region in patients with pelvic fractures and evaluate the use of initial CT imaging as an adjunctive diagnostic tool to identify open injuries. A retrospective review of a prospectively collected database was performed at a single institution. Seven hundred and twenty-two consecutive patients with a pelvic disruption over a two-year period were included. Review of initial injury CT scans was performed using bone and lung viewing algorithms to identify the presence of extra-luminal air. The primary outcome was the presence, location and source of air identified on pre-operative CT scans. Secondary measurements were identification of air by plain radiograph and correlation between identified air densities on CT and clinically diagnosed open pelvic fractures. Ninety-eight patients were identified as having extra-luminal air densities on CT scans. Eighty-one patients were included in the final analysis following application of inclusion and exclusion criteria. Air was noted by the radiologist in forty-five (55.6%) instances. Six patients (7.4%) were clinically diagnosed with an open pelvic ring disruption; in two patients (2.4%) this diagnosis was delayed. In all patients, the CT was able to track air from its origin. In patients with pelvic disruptions, the injury CT should also be evaluated for the presence and source of extra-luminal air. In some patients, this finding may represent an open pelvic ring disruption. A complete physical exam and CT evaluation should be used to decrease the missed or delayed diagnosis of an open pelvic ring

  9. SU-D-BRA-06: Duodenal Interfraction Motion with Abdominal Compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Witztum, A; Holyoake, D; Warren, S

    Purpose: To quantify the effect of abdominal compression on duodenal motion during pancreatic radiotherapy. Methods: Seven patients treated for pancreatic cancer were selected for analysis. Four patients were treated with abdominal compression and three without. The duodenum was contoured by the same physician on each CBCT (five CBCTs for patients with compression, four for non-compression patients). CBCTs were rigidly registered using a soft tissue match and contours were copied to the delivered plans which were all radical (BED > 50 Gy). The distance between the duodenum on the planning CT and each CBCT was quantified by calculating the root meanmore » square (RMS) distance. The DVHs of each abdominal compression patient was converted to an EQD2 DVH (alpha/beta = 10) using an in-house tool and volumes receiving at least 25, 35, 45, and 50 Gy were recorded. Results: The maximum variation in duodenal volumes on the CBCTs for the four abdominal compression patients were 19.1 cm{sup 3} (32.8%), 19.1 cm{sup 3} (20.6%), 19.9 cm{sup 3} (14.3%), and 12.9 cm{sup 3} (27.3%) compared to 15.2 cm{sup 3} (17.6%), 34.7 cm{sup 3} (83.4%), and 56 cm{sup 3} (60.2%) for non-compression patients. The average RMS distance between the duodenum on the planning CT and each CBCT for all abdominal compression patients was 0.3 cm compared to 0.7 cm for non-compressed patients. The largest (and average) difference between the planning CT and CBCTs in volume of duodenum receiving more than 25, 35, 45 and 50 Gy for abdominal compression patients was 11% (5%), 9% (3%), 9% (2%), and 6% (1%). Conclusion: Abdominal compression reduces variation in volume and absolute position of the duodenum throughout treatment. This is seen as an improvement but does not eliminate the need to consider dosimetric effects of motion. Abdominal compression is particularly useful in SBRT when only a few fractions are delivered. Alon Witztum is supported by an MRC/Gray Institute DPhil Studentship. Daniel Holyoake

  10. Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

    NASA Technical Reports Server (NTRS)

    Dulchavsky, S. A.; Henry, S. E.; Moed, B. R.; Diebel, L. N.; Marshburn, T.; Hamilton, D. R.; Logan, J.; Kirkpatrick, A. W.; Williams, D. R.

    2002-01-01

    Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications.

  11. Exams: The Secret Ingredients

    ERIC Educational Resources Information Center

    DiJulio, Betsy

    2012-01-01

    This year, many high-school teachers in the district where the author teaches experienced exam anxiety because midterms--as they had come to know and love them--were no more. For a variety of reasons, the semester exam schedule looked very different. More to the point is the new philosophy about exam content and format that underpinned the…

  12. An algorithm for intelligent sorting of CT-related dose parameters

    NASA Astrophysics Data System (ADS)

    Cook, Tessa S.; Zimmerman, Stefan L.; Steingal, Scott; Boonn, William W.; Kim, Woojin

    2011-03-01

    Imaging centers nationwide are seeking innovative means to record and monitor CT-related radiation dose in light of multiple instances of patient over-exposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose-length product (DLP)-an indirect estimate of radiation dose-requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, Arterial could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired, and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  13. An algorithm for intelligent sorting of CT-related dose parameters.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Boonn, William W; Kim, Woojin

    2012-02-01

    Imaging centers nationwide are seeking innovative means to record and monitor computed tomography (CT)-related radiation dose in light of multiple instances of patient overexposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival, and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose length product (DLP)--an indirect estimate of radiation dose--requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, "arterial" could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  14. Complications in CT-guided procedures: do we really need postinterventional CT control scans?

    PubMed

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-02-01

    The aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans. Retrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only. The complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21). Complications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  15. The relationship of body mass index and abdominal fat on the radiation dose received during routine computed tomographic imaging of the abdomen and pelvis.

    PubMed

    Chan, Victoria O; McDermott, Shaunagh; Buckley, Orla; Allen, Sonya; Casey, Michael; O'Laoide, Risteard; Torreggiani, William C

    2012-11-01

    To determine the relationship of increasing body mass index (BMI) and abdominal fat on the effective dose acquired from computed tomography (CT) abdomen and pelvis scans. Over 6 months, dose-length product and total milliamp-seconds (mAs) from routine CT abdomen and pelvis scans of 100 patients were recorded. The scans were performed on a 64-slice CT scanner by using an automatic exposure control system. Effective dose (mSv) based on dose-length product, BMI, periumbilical fat thickness, and intra-abdominal fat were documented for each patient. BMI, periumbilical fat thickness, and intra-abdominal fat were compared with effective dose. Thirty-nine men and 61 women were included in the study (mean age, 56.3 years). The mean BMI was 26.2 kg/m(2). The mean effective dose was 10.3 mSv. The mean periumbilical fat thickness was 2.4 cm. Sixty-five patients had a small amount of intra-abdominal fat, and 35 had a large amount of intra-abdominal fat. The effective dose increased with increasing BMI (P < .001) and increasing amounts of intra-abdominal fat (P < .001). For every kilogram of weight, there is a 0.13 mSv increase in effective dose, which is equal to 6.5 chest radiographs per CT examination. For an increase in BMI by 5 kg/m(2), there is a 1.95 mSv increase in effective dose, which is equal to 97.5 chest radiographs per CT examination. Increasing BMI and abdominal fat significantly increases the effective dose received from CT abdomen and pelvis scans. Copyright © 2012 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  16. CT findings of acute cholecystitis and its complications.

    PubMed

    Shakespear, Jonathan S; Shaaban, Akram M; Rezvani, Maryam

    2010-06-01

    The purpose of this article is to describe and illustrate the CT findings of acute cholecystitis and its complications. CT findings suggesting acute cholecystitis should be interpreted with caution and should probably serve as justification for further investigation with abdominal ultrasound. CT has a relatively high negative predictive value, and acute cholecystitis is unlikely in the setting of a negative CT. Complications of acute cholecystitis have a characteristic CT appearance and include necrosis, perforation, abscess formation, intraluminal hemorrhage, and wall emphysema.

  17. Association between Abdominal Fat (DXA) and Its Subcomponents (CT Scan) before and after Weight Loss in Obese Postmenopausal Women: A MONET Study.

    PubMed

    Doyon, Caroline Y; Brochu, Martin; Messier, Virginie; Lavoie, Marie-Ève; Faraj, May; Doucet, Eric; Rabasa-Lhoret, Rémi; Dionne, Isabelle J

    2011-01-01

    Introduction. Subcutaneous fat (ScF) and visceral fat (VF) measurements using CT scan are expensive and may imply significant radiation doses. Cross-sectional studies using CT scan showed that ScF and VF are significantly correlated with abdominal fat measured by DXA (AF-DXA). The association has not been studied after a weight loss. Objective. To determine (1) the associations between AF-DXA and ScF and VF before and after weight loss and (2) the associations between their changes. Methods. 137 overweight/obese postmenopausal women were divided in two groups (1-caloric restriction or 2-caloric restriction + resistance training). AF was assessed using DXA and CT scan. Results. Correlations between AF-DXA and ScF (before: r = 0.87, after; r = 0.87; P < .01) and, AF-DXA and VF (before: r = 0.61, after; r = 0.69; P < .01) are not different before and after the weight loss. Correlations between delta AF-DXA and delta ScF (r = 0.72; P < .01) or delta VF (r = 0.51; P < .01) were found. Conclusion. The use of AF-DXA as a surrogate for VF after weight loss is questionable, but may be interesting for ScF.

  18. Association between Abdominal Fat (DXA) and Its Subcomponents (CT Scan) before and after Weight Loss in Obese Postmenopausal Women: A MONET Study

    PubMed Central

    Doyon, Caroline Y.; Brochu, Martin; Messier, Virginie; Lavoie, Marie-Ève; Faraj, May; Doucet, Éric; Rabasa-Lhoret, Rémi; Dionne, Isabelle J.

    2011-01-01

    Introduction. Subcutaneous fat (ScF) and visceral fat (VF) measurements using CT scan are expensive and may imply significant radiation doses. Cross-sectional studies using CT scan showed that ScF and VF are significantly correlated with abdominal fat measured by DXA (AF-DXA). The association has not been studied after a weight loss. Objective. To determine (1) the associations between AF-DXA and ScF and VF before and after weight loss and (2) the associations between their changes. Methods. 137 overweight/obese postmenopausal women were divided in two groups (1-caloric restriction or 2-caloric restriction + resistance training). AF was assessed using DXA and CT scan. Results. Correlations between AF-DXA and ScF (before: r = 0.87, after; r = 0.87; P < .01) and, AF-DXA and VF (before: r = 0.61, after; r = 0.69; P < .01) are not different before and after the weight loss. Correlations between delta AF-DXA and delta ScF (r = 0.72; P < .01) or delta VF (r = 0.51; P < .01) were found. Conclusion. The use of AF-DXA as a surrogate for VF after weight loss is questionable, but may be interesting for ScF. PMID:21603261

  19. Do Collaborative Exams Really Promote Learning?

    NASA Astrophysics Data System (ADS)

    Miller, Scott; James, C. Renee

    2018-01-01

    Collaborative, two-stage exams are becoming more popular in physics and astronomy courses, and their supposed benefits in terms of collaborative learning have been reported in the field of physics. In a collaborative, two-stage exam, students first complete an exam individually. Once that portion of the exam is over, students then retake all or part of the exam within a group, where they are able to discuss the questions with their peers and arrive at a common answer. While there are a number of papers that discuss the purported benefits of this method from a collaborative point of view, few, if any discuss the actual benefits in terms of student learning. One paper found that when students were presented with previous exam questions a few weeks later, they performed better on questions covered previously in the group portion of the exam compared to similar questions which were tested but not part of the group portion. But, when students were retested on exam questions which were administered earlier, roughly six to seven weeks beforehand, no difference was found in their performance on the two sets of questions.We present preliminary findings comparing student performance levels on multiple sets of exam questions administered to students in an introductory astronomy course where two-stage exams are administered. Questions were administered first in an exam during the course of the semester, then again during a final exam. During the semester exams, one set of questions was also contained within the group portion of the exam, while questions similar in concept and difficulty were not. A comparison of student performance on these two sets of questions are compared to evaluate the usefulness of collaborative exams to promote learning.

  20. Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion

    PubMed Central

    Skornitzke, S; Fritz, F; Klauss, M; Pahn, G; Hansen, J; Hirsch, J; Grenacher, L; Kauczor, H-U

    2015-01-01

    Objective: To compare six different scenarios for correcting for breathing motion in abdominal dual-energy CT (DECT) perfusion measurements. Methods: Rigid [RRComm(80 kVp)] and non-rigid [NRComm(80 kVp)] registration of commercially available CT perfusion software, custom non-rigid registration [NRCustom(80 kVp], demons algorithm) and a control group [CG(80 kVp)] without motion correction were evaluated using 80 kVp images. Additionally, NRCustom was applied to dual-energy (DE)-blended [NRCustom(DE)] and virtual non-contrast [NRCustom(VNC)] images, yielding six evaluated scenarios. After motion correction, perfusion maps were calculated using a combined maximum slope/Patlak model. For qualitative evaluation, three blinded radiologists independently rated motion correction quality and resulting perfusion maps on a four-point scale (4 = best, 1 = worst). For quantitative evaluation, relative changes in metric values, R2 and residuals of perfusion model fits were calculated. Results: For motion-corrected images, mean ratings differed significantly [NRCustom(80 kVp) and NRCustom(DE), 3.3; NRComm(80 kVp), 3.1; NRCustom(VNC), 2.9; RRComm(80 kVp), 2.7; CG(80 kVp), 2.7; all p < 0.05], except when comparing NRCustom(80 kVp) with NRCustom(DE) and RRComm(80 kVp) with CG(80 kVp). NRCustom(80 kVp) and NRCustom(DE) achieved the highest reduction in metric values [NRCustom(80 kVp), 48.5%; NRCustom(DE), 45.6%; NRComm(80 kVp), 29.2%; NRCustom(VNC), 22.8%; RRComm(80 kVp), 0.6%; CG(80 kVp), 0%]. Regarding perfusion maps, NRCustom(80 kVp) and NRCustom(DE) were rated highest [NRCustom(80 kVp), 3.1; NRCustom(DE), 3.0; NRComm(80 kVp), 2.8; NRCustom(VNC), 2.6; CG(80 kVp), 2.5; RRComm(80 kVp), 2.4] and had significantly higher R2 and lower residuals. Correlation between qualitative and quantitative evaluation was low to moderate. Conclusion: Non-rigid motion correction improves spatial alignment of the target region and fit of CT

  1. Paediatric abdominal tuberculosis in developed countries: case series and literature review.

    PubMed

    Delisle, Megan; Seguin, Jade; Zeilinski, David; Moore, Dorothy L

    2016-03-01

    To provide an insight into the presentation, diagnosis and management of paediatric abdominal tuberculosis (TB) in developed countries. The records of all children at the Montreal Children's Hospital (MCH) admitted with abdominal TB between 1990 and 2014 were reviewed. An automated and manual literature search from 1946 to 2014 was performed. (1) CASE SERIES: six cases were identified at the MCH. All were male between 5 and 17 years of age. All were from populations known to have high rates of TB (aboriginal, immigrant). Three underwent major surgical interventions and three underwent ultrasound (US) or CT aspiration or biopsy for diagnosis. (2) LITERATURE REVIEW: 29 male (64%) and 16 female subjects (36%) aged between 14 months and 18 years were identified, including the MCH patients. All patients except one were from populations with a high incidence of TB. Most presented with a positive tuberculin skin test (90%), abdominal pain (76%), fever (71%) and weight loss (68%). On imaging, 22 (49%) were classified with gastrointestinal TB with colonic wall irregularity (41%) and 19 (42%) with peritoneal TB with ascites (68%). A positive culture was obtained in 33 (73%) patients. Three cases used CT- or US-guided aspiration or biopsy to obtain tissue samples. A surgical intervention was performed in 34 (76%) children; 13 (38%) of these were for diagnosis. Diagnosis based on clinical features (abdominal pain, fever and weight loss) and CT- or US-guided aspiration or biopsy may encourage physicians to adopt a more conservative approach to abdominal TB. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Initial observations of electronic medical record usage during CT and MRI interpretation: Frequency of use and impact on workflow.

    PubMed

    Lin, Abraham; Harris, Mitchell; Zalis, Michael

    2010-07-01

    Electronic medical record (EMR) systems permit integration of contextual nonimaging EMR data into examination interpretation; however, the extra effort required to search and review these nonradiologic data are not well characterized. We assessed the gross frequency and pattern of EMR usage in the interpretation of diagnostic CT and MRI examinations. We defined nonradiologic EMR data as laboratory data, nonimaging specialty report, clinical note, and administrative data not available on PACS. For abdominal, neuroradiologic, and musculoskeletal CT and MRI, we prospectively recorded the time required for image analysis (including prior imaging studies and their reports), nonradiologic EMR use, and initial report drafting by fellows and staff in randomized sessions. We assessed EMR use as a fraction of work activity and according to technique, subspecialty, inpatient status, and radiologist experience. We observed 372 CT and MRI interpretations by 33 radiologists. For CT, radiologists used the EMR in 34% of abdominal, 57% of neuroradiologic, and 38% of musculoskeletal interpretations. For MRI, EMR was used in 73% of abdominal, 56% of neuroradiologic, and 33% of musculoskeletal interpretations. For CT, EMR usage comprised 18%, 14%, and 18% of diagnostic effort (image analysis plus EMR use) for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively; for MRI, EMR usage comprised 21%, 16%, and 15% of diagnostic effort for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively. Frequency of EMR use was significantly greater for neuroradiology CT and abdominal MRI (p < 0.05, Fisher's test). EMR usage was not consistently related to inpatient status for CT or radiologist experience. For CT and MRI interpretation, EMR usage is frequent and comprises a significant fraction of diagnostic effort.

  3. Focused abdominal sonography for trauma in the clinical evaluation of children with blunt abdominal trauma.

    PubMed

    Ben-Ishay, Offir; Daoud, Mai; Peled, Zvi; Brauner, Eran; Bahouth, Hany; Kluger, Yoram

    2015-01-01

    In pediatric care, the role of focused abdominal sonography in trauma (FAST) remains ill defined. The objective of this study was to assess the sensitivity and specificity of FAST for detecting free peritoneal fluid in children. The trauma registry of a single level I pediatric trauma center was queried for the results of FAST examination of consecutive pediatric (<18 years) blunt trauma patients over a period of 36 months, from January 2010 to December 2012. Demographics, type of injuries, FAST results, computerized tomography (CT) results, and operative findings were reviewed. During the study period, 543 injured pediatric patients (mean age 8.2 ± 5 years) underwent FAST examinations. In 95 (17.5 %) FAST was positive for free peritoneal fluid. CT examination was performed in 219 (40.3 %) children. Positive FAST examination was confirmed by CT scan in 61/73 (83.6 %). CT detected intra-peritoneal fluid in 62/448 (13.8 %) of the patients with negative FAST results. These findings correspond to a sensitivity of 50 %, specificity of 88 %, positive predictive value (PPV) of 84 %, and a negative predictive value (NPV) of 58 %. In patients who had negative FAST results and no CT examination (302), no missed abdominal injury was detected on clinical ground. FAST examination in the young age group (<2 years) yielded lower sensitivity and specificity (36 and 78 % respectively) with a PPV of only 50 %. This study shows that although a positive FAST evaluation does not necessarily correlate with an IAI, a negative one strongly suggests the absence of an IAI, with a high NPV. These findings are emphasized in the analysis of the subgroup of children less than 2 years of age. FAST examination tempered with sound clinical judgment seems to be an effective tool to discriminate injured children in need of further imaging evaluation.

  4. Automatic segmentation of the liver using multi-planar anatomy and deformable surface model in abdominal contrast-enhanced CT images

    NASA Astrophysics Data System (ADS)

    Jang, Yujin; Hong, Helen; Chung, Jin Wook; Yoon, Young Ho

    2012-02-01

    We propose an effective technique for the extraction of liver boundary based on multi-planar anatomy and deformable surface model in abdominal contrast-enhanced CT images. Our method is composed of four main steps. First, for extracting an optimal volume circumscribing a liver, lower and side boundaries are defined by positional information of pelvis and rib. An upper boundary is defined by separating the lungs and heart from CT images. Second, for extracting an initial liver volume, optimal liver volume is smoothed by anisotropic diffusion filtering and is segmented using adaptively selected threshold value. Third, for removing neighbor organs from initial liver volume, morphological opening and connected component labeling are applied to multiple planes. Finally, for refining the liver boundaries, deformable surface model is applied to a posterior liver surface and missing left robe in previous step. Then, probability summation map is generated by calculating regional information of the segmented liver in coronal plane, which is used for restoring the inaccurate liver boundaries. Experimental results show that our segmentation method can accurately extract liver boundaries without leakage to neighbor organs in spite of various liver shape and ambiguous boundary.

  5. [Perforation of hollow organs in the abdominal contusion: diagnostic features and prognostic factors of death].

    PubMed

    Nicolau, A E; Merlan, V; Dinescu, G; Crăciun, M; Kitkani, A; Beuran, M

    2012-01-01

    Blunt hollow viscus perforations (HVP) due to abdominal contusions (AC), although rare, are difficult to diagnose early and are associated with a high mortality. Our paper analyses retrospectively data from patients operated for HVP between January 2005 and January 2009, the efficiency of different diagnostic tools, mortality and prognostic factors for death. There were 62 patients operated for HVP, 14 of which had isolated abdominal contusion and 48 were poly trauma patients. There were 9 women and 53 men, the mean age was 41.5 years (SD: +17,9), the mean ISS was 32.94 (SD: +15,94), 23 patients had associated solid viscus injuries (SVI). Clinical examination was irelevant for 16 of the 62 patients, abdominal Xray was false negative for 30 out of 35 patients and abdominal ultrasound was false negative for 16 out of 60 patients. Abdominal CT was initially false negative for 7 out of 38 patients: for 4 of them the abdominal CT was repeated and was positive for HVP, for 3 patients a diagnostic laparoscopy was performed. Direct signs for HVP on abdominal CT were present for 3 out of 38 patients. Diagnostic laparoscopy was performed for 7 patients with suspicion for HVP, and was positive for 6 of them and false negative for a patient with a duodenal perforation. Single organ perforations were present in 55 cases, multi organ perforations were present in 7 cases. There were 15 deaths (15.2%), most of them caused by haemodynamic instability (3 out of 6 patients) and associated lesions: SOL for 9 out of 23 cases, pelvic fracture (PF) for 6 out of 14 patients, craniocerebral trauma (CCT) for 12 out of 33 patients.Multivariate analysis showed that the prognostic factors for death were ISS value (p = 0,023) and associated CCT (odds ratio = 4,95; p = 0,017). The following factors were not confirmed as prognostic factors for death: age, haemodynamic instability, associated SVI, thoracic trauma (TT), pelvic fractures (PF), limbs fractures (LF) and admission-operation interval

  6. Matrix metalloproteinase-2 gene variants and abdominal aortic aneurysm.

    PubMed

    Smallwood, L; Warrington, N; Allcock, R; van Bockxmeer, F; Palmer, L J; Iacopetta, B; Golledge, J; Norman, P E

    2009-08-01

    To investigate associations between two polymorphisms of the matrix metalloproteinase-2 gene (MMP2) and the incidence and progression of abdominal aortic aneurysm (AAA). Cases and controls were recruited from a trial of screening for AAAs. The association between two variants of MMP2 (-1360C>T, and +649C>T) in men with AAA (n=678) and in controls (n=659) was examined using multivariate analyses. The association with AAA expansion (n=638) was also assessed. In multivariate analyses with adjustments for multiple testing, no association between either SNP and AAA presence or expansion was detected. MMP2 -1360C>T and +649C>T variants are not risk factors for AAA.

  7. Appendicitis following blunt abdominal trauma.

    PubMed

    Cobb, Travis

    2017-09-01

    Appendicitis is a frequently encountered surgical problem in the Emergency Department (ED). Appendicitis typically results from obstruction of the appendiceal lumen, although trauma has been reported as an infrequent cause of acute appendicitis. Intestinal injury and hollow viscus injury following blunt abdominal trauma are well reported in the literature but traumatic appendicitis is much less common. The pathophysiology is uncertain but likely results from several mechanisms, either in isolation or combination. These include direct compression/crush injury, shearing injury, or from indirect obstruction of the appendiceal lumen by an ileocecal hematoma or traumatic impaction of stool into the appendix. Presentation typically mirrors that of non-traumatic appendicitis with nausea, anorexia, fever, and right lower quadrant abdominal tenderness and/or peritonitis. Evaluation for traumatic appendicitis requires a careful history and physical exam. Imaging with ultrasound or computed tomography is recommended if the history and physical do not reveal an acute surgical indication. Treatment includes intravenous antibiotics and surgical consultation for appendectomy. This case highlights a patient who developed acute appendicitis following blunt trauma to the abdomen sustained during a motor vehicle accident. Appendicitis must be considered as part of the differential diagnosis in any patient who presents to the ED with abdominal pain, including those whose pain begins after sustaining blunt trauma to the abdomen. Because appendicitis following trauma is uncommon, timely diagnosis requires a high index of suspicion. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. [Why are some high achievers on the course final exam unsuccessful on the proficiency exam in English?].

    PubMed

    Matsunuma, Mitsuyasu

    2009-04-01

    This study examined why some high achievers on the course final exam were unsuccessful on the proficiency exam in English. We hypothesized that the learning motives and learning behaviors (learning strategy, learning time) had different effects on the outcomes of the exams. First, the relation between the variables was investigated using structural equation modeling. Second, the learning behaviors of students who got good marks on both exams were compared with students who did well only on the course final exam. The results were as follows. (a) Learning motives influenced test performance via learning behaviors. (b) Content-attached motives influenced all variables concerning learning behaviors. (c) Content-detached motives influenced all variables concerning learning behaviors that were related only to the course final exam. (d) The students who got good marks on both exams performed the learning behaviors that were useful on the proficiency exam more frequently than the students who did well only on the course final exam.

  9. Estimation of CT-Derived Abdominal Visceral and Subcutaneous Adipose Tissue Depots from Anthropometry in Europeans, South Asians and African Caribbeans

    PubMed Central

    Eastwood, Sophie V.; Tillin, Therese; Wright, Andrew; Heasman, John; Willis, Joseph; Godsland, Ian F.; Forouhi, Nita; Whincup, Peter; Hughes, Alun D.; Chaturvedi, Nishi

    2013-01-01

    Background South Asians and African Caribbeans experience more cardiometabolic disease than Europeans. Risk factors include visceral (VAT) and subcutaneous abdominal (SAT) adipose tissue, which vary with ethnicity and are difficult to quantify using anthropometry. Objective We developed and cross-validated ethnicity and gender-specific equations using anthropometrics to predict VAT and SAT. Design 669 Europeans, 514 South Asians and 227 African Caribbeans (70±7 years) underwent anthropometric measurement and abdominal CT scanning. South Asian and African Caribbean participants were first-generation migrants living in London. Prediction equations were derived for CT-measured VAT and SAT using stepwise regression, then cross-validated by comparing actual and predicted means. Results South Asians had more and African Caribbeans less VAT than Europeans. For basic VAT prediction equations (age and waist circumference), model fit was better in men (R2 range 0.59-0.71) than women (range 0.35-0.59). Expanded equations (+ weight, height, hip and thigh circumference) improved fit for South Asian and African Caribbean women (R2 0.35 to 0.55, and 0.43 to 0.56 respectively). For basic SAT equations, R2 was 0.69-0.77, and for expanded equations it was 0.72-0.86. Cross-validation showed differences between actual and estimated VAT of <7%, and SAT of <8% in all groups, apart from VAT in South Asian women which disagreed by 16%. Conclusion We provide ethnicity- and gender-specific VAT and SAT prediction equations, derived from a large tri-ethnic sample. Model fit was reasonable for SAT and VAT in men, while basic VAT models should be used cautiously in South Asian and African Caribbean women. These equations will aid studies of mechanisms of cardiometabolic disease in later life, where imaging data are not available. PMID:24069381

  10. Estimation of CT-derived abdominal visceral and subcutaneous adipose tissue depots from anthropometry in Europeans, South Asians and African Caribbeans.

    PubMed

    Eastwood, Sophie V; Tillin, Therese; Wright, Andrew; Heasman, John; Willis, Joseph; Godsland, Ian F; Forouhi, Nita; Whincup, Peter; Hughes, Alun D; Chaturvedi, Nishi

    2013-01-01

    South Asians and African Caribbeans experience more cardiometabolic disease than Europeans. Risk factors include visceral (VAT) and subcutaneous abdominal (SAT) adipose tissue, which vary with ethnicity and are difficult to quantify using anthropometry. We developed and cross-validated ethnicity and gender-specific equations using anthropometrics to predict VAT and SAT. 669 Europeans, 514 South Asians and 227 African Caribbeans (70 ± 7 years) underwent anthropometric measurement and abdominal CT scanning. South Asian and African Caribbean participants were first-generation migrants living in London. Prediction equations were derived for CT-measured VAT and SAT using stepwise regression, then cross-validated by comparing actual and predicted means. South Asians had more and African Caribbeans less VAT than Europeans. For basic VAT prediction equations (age and waist circumference), model fit was better in men (R(2) range 0.59-0.71) than women (range 0.35-0.59). Expanded equations (+ weight, height, hip and thigh circumference) improved fit for South Asian and African Caribbean women (R(2) 0.35 to 0.55, and 0.43 to 0.56 respectively). For basic SAT equations, R(2) was 0.69-0.77, and for expanded equations it was 0.72-0.86. Cross-validation showed differences between actual and estimated VAT of <7%, and SAT of <8% in all groups, apart from VAT in South Asian women which disagreed by 16%. We provide ethnicity- and gender-specific VAT and SAT prediction equations, derived from a large tri-ethnic sample. Model fit was reasonable for SAT and VAT in men, while basic VAT models should be used cautiously in South Asian and African Caribbean women. These equations will aid studies of mechanisms of cardiometabolic disease in later life, where imaging data are not available.

  11. TH-AB-207A-04: Assessment of Patients’ Cumulative Effective Dose From CT Examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostani, M; Cagnon, C; Sepahdari, A

    Purpose: The Joint Commission requires institutions to consider patient’s age and recent imaging exams when deciding on the most appropriate type of imaging exam. Additionally, knowing patient’s imaging history can help prevent duplicate scans. Radiation dose management software affords new opportunities to identify and utilize patients with high cumulative doses as one proxy for subsequent review of imaging history and opportunities in avoiding redundant exams. Methods: Using dose management software (Radimetrics, Bayer Healthcare) a total of 72073 CT examinations performed from Jan 2015 to Jan 2016 were examined to categorize patients with a cumulative effective dose of 100 mSv andmore » above. This threshold was selected based on epidemiological studies on populations exposed to radiation, which demonstrate a statistical increase of cancer risk at doses above 100 mSv. Histories of patients with highest cumulative dose and highest number of exams were further investigated by a Radiologist for appropriateness of recurrent studies and potential opportunities for reduction. Results: Out of 34762 patients, 927 (2.7%) were identified with a cumulative dose of 100 mSv and above. The highest cumulative dose (842 mSv) belonged to an oncology patient who underwent 2 diagnostic exams and 9 interventional ablative CT guided procedures. The patient with highest number of exams (56 counts) and cumulative dose of 170 mSv was a 17 year old trauma patient. An imaging history review of these two patients did not suggest any superfluous scans. Conclusion: Our limited pilot study suggests that recurrent CT exams for patients with oncologic or severe trauma history may be warranted and appropriate. As a result, for future studies we will be focusing on high dose patient cohorts not associated with oncology or severe trauma. Additionally, the review process itself has suggested areas for potential improvement in patient care, including improved documentation and Radiologist

  12. Risk Assessment of Abdominal Wall Thickness Measured on Pre-Operative Computerized Tomography for Incisional Surgical Site Infection after Abdominal Surgery.

    PubMed

    Tongyoo, Assanee; Chatthamrak, Putipan; Sriussadaporn, Ekkapak; Limpavitayaporn, Palin; Mingmalairak, Chatchai

    2015-07-01

    The surgical site infection (SSI) is a common complication of abdominal operation. It relates to increased hospital stay, increased healthcare cost, and decreased patient's quality of life. Obesity, usually defined by BMI, is known as one of the risks of SSI. However, the thickness of subcutaneous layers of abdominal wall might be an important local factor affecting the rate of SSI after the abdominal operations. The objective of this study is to assess the importance of the abdominal wall thickness on incisional SSI rate. The subjects of the present study were patients who had undergone major abdominal operations at Thammasat University Hospital between June 2013 and May 2014, and had been investigated with CT scans before their operations. The demographic data and clinical information of these patients were recorded. The thickness ofsubcutaneous fatty tissue from skin down to the most superficial layer of abdominal wall muscle at the surgical site was measured on CT images. The wound infectious complication was reviewed and categorized as superficial and deep incisional SSIfollowing the definition from Centersfor Disease Control and Prevention (CDC) guidelines. The significance ofeach potentialfactors on SSI rates was determined separately with student t-test for quantitative data and χ2-test for categorical data. Then all factors, which had p < 0.10, were included into the multivariate logistic regression analysis and were analyzed with significance at p < 0.05. One hundred and thirty-nine patients were included in this study. They all underwent major abdominal surgery and had had pre-operative CTscans. Post-operative SSI was 25.2% (35/139), superficial and deep types in 27 and 8 patients, respectively. The comparison of abdominal wall thickness between patients with and without infection was significantly different (20.0 ± 8.4 mm and 16.0 ± 7.2 mm, respectively). When the thickness at 20 mm was used as the cut-off value, 43 of 139 patients had abdominal wall

  13. [Unclear Abdominal Pain - Not Always a Gastroenterological Emergency].

    PubMed

    Aschoff, Anna Teresa; Pech, Maciej; Fischbach, Frank; Ricke, Jens; Luani, Blerim; Braun-Dullaeus, Rüdiger Christian; Herold, Jörg

    2017-04-01

    History and admission findings  An 84-year old patient with persistent atrial fibrillation and chronic renal failure received a subcutaneous injection with low molecular weight heparin (LMWH) during a hospital stay. Over the course of her hospitalization, the patient developed abdominal pain. There was a marked hematoma at the injection site. A large tumor was palpable in the right abdominal quadrant. Examinations  Due to the significant reduction in hemoglobin, we performed a CT-angiogram of the abdomen. Diagnosis  We were able to visualize an intramuscular hematoma within the rectus abdominis muscle. Therapy and clinical course  After visualization with digital subtraction angiography and application of microcoils and histoacryl-glue, we were able to stop bleeding. After implantation of left atrial appendage occluder, oral anticoagulation therapy could be stopped. Conclusion  LMWH-treated patients with nonspecific abdominal pain should be meticulously examined to exclude iatrogenic abdominal muscle hematoma. © Georg Thieme Verlag KG Stuttgart · New York.

  14. SU-F-I-31: Reproducibility of An Automatic Exposure Control Technique in the Low-Dose CT Scan of Cardiac PET/CT Exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, M; Rosica, D; Agarwal, V

    Purpose: Two separate low-dose CT scans are usually performed for attenuation correction of rest and stress N-13 ammonia PET/CT myocardial perfusion imaging (PET/CT). We utilize an automatic exposure control (AEC) technique to reduce CT radiation dose while maintaining perfusion image quality. Our goal is to assess the reproducibility of displayed CT dose index (CTDI) on same-day repeat CT scans (CT1 and CT2). Methods: Retrospectively, we reviewed CT images of PET/CT studies performed on the same day. Low-dose CT utilized AEC technique based on tube current modulation called Smart-mA. The scan parameters were 64 × 0.625mm collimation, 5mm slice thickness, 0.984more » pitch, 1-sec rotation time, 120 kVp, and noise index 50 with a range of 10–200 mA. The scan length matched with PET field of view (FOV) with the heart near the middle of axial FOV. We identified the reference slice number (RS) for an anatomical landmark (carina) and used it to estimate axial shift between two CTs. For patient size, we measured an effective diameter on the reference slice. The effect of patient positioning to CTDI was evaluated using the table height. We calculated the absolute percent difference of the CTDI (%diff) for estimation of the reproducibility. Results: The study included 168 adults with an average body-mass index of 31.72 ± 9.10 (kg/m{sup 2}) and effective diameter was 32.72 ± 4.60 cm. The average CTDI was 1.95 ± 1.40 mGy for CT1 and 1.97 ± 1.42mGy for CT2. The mean %diff was 7.8 ± 6.8%. Linear regression analysis showed a significant correlation between the table height and %diff CTDI. (r=0.82, p<0.001) Conclusion: We have shown for the first time in human subjects, using two same-day CT images, that the AEC technique in low-dose CT is reproducible within 10% and significantly depends on the patient centering.« less

  15. Thoracic-abdominal imaging with a novel dual-layer spectral detector CT: intra-individual comparison of image quality and radiation dose with 128-row single-energy acquisition.

    PubMed

    Haneder, Stefan; Siedek, Florian; Doerner, Jonas; Pahn, Gregor; Grosse Hokamp, Nils; Maintz, David; Wybranski, Christian

    2018-01-01

    Background A novel, multi-energy, dual-layer spectral detector computed tomography (SDCT) is commercially available now with the vendor's claim that it yields the same or better quality of polychromatic, conventional CT images like modern single-energy CT scanners without any radiation dose penalty. Purpose To intra-individually compare the quality of conventional polychromatic CT images acquired with a dual-layer spectral detector (SDCT) and the latest generation 128-row single-energy-detector (CT128) from the same manufacturer. Material and Methods Fifty patients underwent portal-venous phase, thoracic-abdominal CT scans with the SDCT and prior CT128 imaging. The SDCT scanning protocol was adapted to yield a similar estimated dose length product (DLP) as the CT128. Patient dose optimization by automatic tube current modulation and CT image reconstruction with a state-of-the-art iterative algorithm were identical on both scanners. CT image contrast-to-noise ratio (CNR) was compared between the SDCT and CT128 in different anatomic structures. Image quality and noise were assessed independently by two readers with 5-point-Likert-scales. Volume CT dose index (CTDI vol ), and DLP were recorded and normalized to 68 cm acquisition length (DLP 68 ). Results The SDCT yielded higher mean CNR values of 30.0% ± 2.0% (26.4-32.5%) in all anatomic structures ( P < 0.001) and excellent scores for qualitative parameters surpassing the CT128 (all P < 0.0001) with substantial inter-rater agreement (κ ≥ 0.801). Despite adapted scan protocols the SDCT yielded lower values for CTDI vol (-10.1 ± 12.8%), DLP (-13.1 ± 13.9%), and DLP 68 (-15.3 ± 16.9%) than the CT128 (all P < 0.0001). Conclusion The SDCT scanner yielded better CT image quality compared to the CT128 and lower radiation dose parameters.

  16. Preparing Students for the AP Psychology Exam

    ERIC Educational Resources Information Center

    Whitlock, Kristin

    2013-01-01

    The Advanced Placement Psychology exam is one of the fastest growing exams offered by the College Board. The average percent of change in the number of students taking this exam over the past five years is 12.4%. With 238,962 students taking the exam in 2013, the AP Psychology exam is the sixth largest exam, surpassing AP Biology and AP World…

  17. The focused abdominal sonography for trauma examination can reliably identify patients with significant intra-abdominal hemorrhage in life-threatening pelvic fractures.

    PubMed

    Christian, Nicole Townsend; Burlew, Clay Cothren; Moore, Ernest E; Geddes, Andrea E; Wagenaar, Amy E; Fox, Charles J; Pieracci, Fredric M

    2018-06-01

    The focused abdominal sonography for trauma (FAST) examination has been reported to be unreliable in pelvic fracture patients. Additionally, given the advent of new therapeutic interventions, such as resuscitative endovascular balloon occlusion of the aorta (REBOA), rapid identification of intra-abdominal hemorrhage compared with Zone III hemorrhage may guide different therapeutic strategies. We hypothesized that FAST is reliable for detecting clinically significant intra-abdominal hemorrhage in the face of complex pelvic fractures. Our pelvic fracture database of all hemodynamically unstable patients requiring intervention from January 1, 2005, to July 1, 2015, was reviewed. The FAST examination was compared with operative and computed tomography (CT) scan findings. Confirmatory evaluation for FAST(-) patients was considered positive if therapeutic intervention was required. During the study period, 81 patients in refractory shock with FAST imaging in our emergency department (ED) underwent pelvic packing. Mean age was 45 ± 2 years and Injury Severity Score was 50 ± 1.5. The FAST examination was negative in 53 patients; 52 patients did not require operative intervention for abdominal bleeding while one patient required splenectomy. The FAST examination was positive in 28 patients; 26 had findings confirmed by CT or laparotomy while two patients did not have intra-abdominal hemorrhage on further evaluation. The sensitivity and specificity for FAST in this population was 96% and 96%, respectively, positive predictive value was 93%, and negative predictive value was 98%. The false-negative and -positive rates for FAST were 2% and 7%. Focused abdominal sonography for trauma examination reliably identifies clinically significant hemoperitoneum in life-threatening, pelvic fracture related hemorrhage. The incidence of a false-negative FAST in this unstable pelvic fracture population was 2%. FAST results may be used when determining the role of REBOA in these

  18. Primary intra-abdominal malignant fibrous histiocytoma: a highly aggressive tumor.

    PubMed

    Salemis, Nikolaos S; Gourgiotis, Stavros; Tsiambas, Evangelos; Panagiotopoulos, Nikolaos; Karameris, Andreas; Tsohataridis, Efstathios

    2010-12-01

    Malignant fibrous histiocytoma (MFH) is the most common soft-tissue sarcoma of late adult life occurring predominantly in the extremities. Primary intra-abdominal MFH is a very rare occurrence. The aim of this study is to describe a very rare case of an intra-abdominal MFH with a highly aggressive clinical course. A 67-year-old male was referred to our department with a 2-week history of dull lower abdominal pain and a gradually enlarging right lower abdominal mass, which he first noticed 2 months prior to admission. Computed tomography (CT) scan demonstrated a mass in the right iliac fossa. On exploratory laparotomy, a tumor was found in the right iliac fossa attached to the parietal lateral peritoneum without any evidence of invasion into the adjacent structures. Complete excision of the tumor with clear margins was performed. Histological and immunohistochemical examinations showed a MFH. One month after surgery, while on adjuvant chemotherapy, the patient was readmitted with dyspnea and a slightly palpable mass in the area of the previous radical resection. CT scan revealed local tumor recurrence along with multiple pulmonary metastatic deposits. Unfortunately, despite treatment, the patient died of progressive disease 5 weeks later. Primary intra-abdominal MFH is a very rare but aggressive malignancy with a high tendency of local recurrence and metastatic spread. Early detection and complete surgical excision with clear margins is the treatment of choice. In some cases, however, the tumor can exhibit a highly aggressive clinical course despite radical surgery and adjuvant therapy.

  19. Diagnostic Accuracy of MRI Versus CT for the Evaluation of Acute Appendicitis in Children and Young Adults.

    PubMed

    Kinner, Sonja; Pickhardt, Perry J; Riedesel, Erica L; Gill, Kara G; Robbins, Jessica B; Kitchin, Douglas R; Ziemlewicz, Timothy J; Harringa, John B; Reeder, Scott B; Repplinger, Michael D

    2017-10-01

    Appendicitis is frequently diagnosed in the emergency department, most commonly using CT. The purpose of this study was to compare the diagnostic accuracy of contrast-enhanced MRI with that of contrast-enhanced CT for the diagnosis of appendicitis in adolescents when interpreted by abdominal radiologists and pediatric radiologists. Our study included a prospectively enrolled cohort of 48 patients (12-20 years old) with nontraumatic abdominal pain who underwent CT and MRI. Fellowship-trained abdominal and pediatric radiologists reviewed all CT and MRI studies in randomized order, blinded to patient outcome. Likelihood for appendicitis was rated on a 5-point scale (1, definitely not appendicitis; 5, definitely appendicitis) for CT, the unenhanced portion of the MRI, and the entire contrast-enhanced MRI study. ROC curves were generated and AUC compared for each scan type for all six readers and then stratified by radiologist type. Image test characteristics, interrater reliability, and reading times were compared. Sensitivity and specificity were 85.9% (95% CI, 76.2-92.7%) and 93.8% (95% CI, 89.7-96.7%) for unenhanced MRI, 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for contrast-enhanced MRI, and 93.6% (95% CI, 85.6-97.9%) and 94.3% (95% CI, 90.2-97%) for CT. No difference was found in the diagnostic accuracy or interpretation time when comparing abdominal radiologists to pediatric radiologists (CT, 3.0 min vs 2.8 min; contrast-enhanced MRI, 2.4 min vs 1.8 min; unenhanced MRI, 1.5 min vs 2.3 min). Substantial agreement between abdominal and pediatric radiologists was seen for all methods (κ = 0.72-0.83). The diagnostic accuracy of MRI to diagnose appendicitis was very similar to CT. No statistically significant difference in accuracy was observed between imaging modality or radiologist subspecialty.

  20. Physics Exams That Promote Collaborative Learning

    ERIC Educational Resources Information Center

    Wieman, Carl E.; Rieger, Georg W.; Heiner, Cynthia E.

    2014-01-01

    The two-stage exam is a relatively simple way to introduce collaborative learning and formative assessment into an exam. Their use is rapidly growing in the physics department at the University of British Columbia, as both students and faculty find them rewarding. In a two-stage exam students first complete and turn in the exam individually, and…

  1. Alpha-galactosidase versus active charcoal for improving sonographic visualization of abdominal organs in patients with excessive intestinal gas

    PubMed Central

    Maconi, G.; Bolzacchini, E.; Radice, E.; Marzocchi, M.; Badini, M.

    2012-01-01

    Background and aims Intestinal gas is a frequent cause of poor visualization during gastrointestinal ultrasound (US). The enzyme alpha-galactosidase may reduce intestinal gas production, thereby improving abdominal US visualization. We compared the efficacies of alpha-galactosidase and active charcoal in improving US visualization in patients with previous unsatisfactory abdominal US scans caused by excessive intestinal gas. Materials and methods: 45 patients with poor visualization of at least one target organ: pancreas, hepatic lobes (score 0–2) or common bile duct (CBD) (score 0–1) were enrolled in a prospective randomized, crossover, observer-blinded study. The patients received alpha-galactosidase (Sinaire Forte, Promefarm, Milan, Italy) 600 GalU t.i.d. for 2 days before abdominal US plus 900 GalU the morning of exam or active charcoal 448 mg t.i.d., for 2 days before the exam plus 672 mg the morning of the exam. Visualization was graded as follows: 0 = none (complete gas interference); 1 = severe interference, 2 = moderate interference, 3 = mild interference; 4 = complete (no gas interference). Results: 42 patients completed the study. Both alpha-galactosidase and active charcoal improved the visualization of target organs. Visualization of the right hepatic lobe, CBD and pancreatic tail was significantly improved (vs. baseline) only by alpha-galactosidase (p < 0.01). Scores ≥3 for all parts of the pancreas and both hepatic lobes were achieved in only 12.5% of the patients after both treatments. Both products were well tolerated. Conclusion: Alpha-galactosidase and active charcoal can improve US visualization of abdominal organs in patients whose scans are frequently unsatisfactory due to excessive intestinal gas. Visualization of the pancreatic tail and right hepatic lobe was significantly improved only by alpha-galactosidase. However, both treatments allowed adequate visualization of all target organs during the same examination only

  2. Investigating the Written Exam Scores' Prediction Power of TEOG Exam Scores

    ERIC Educational Resources Information Center

    Kontas, Hakki; Özpolat, Esen Turan

    2017-01-01

    The purpose of this study was to investigate exam scores' predicting Transition from Primary to Secondary Education (TEOG) exam scores. The research data were obtained from the records of 1035 students studying at the first term of eighth grade in 2015-2016 academic year in e-school system. The research was on relational screening model. Linear…

  3. Grey Turner's and Cullen's signs induced by spontaneous hemorrhage of the abdominal wall after coughing.

    PubMed

    Fan, Zhe; Zhang, Yingyi

    2017-08-01

    Grey Turner's and Cullen's signs are rare clinical signs, which most appear in patients with severe acute pancreatitis. The present patient complained of abdominal pain after coughing. However, contrast-enhanced CT revealed a hemorrhage of the abdominal wall. Therefore, spontaneous hemorrhage of the abdominal wall was diagnosed. The patient recovered through immobilization and hemostasis therapy. This case report and literature review aims to remind clinicians of manifestations and treatment of spontaneous hemorrhage.

  4. Saliva pH as a biomarker of exam stress and a predictor of exam performance.

    PubMed

    Cohen, Miri; Khalaila, Rabia

    2014-11-01

    Salivary pH is regulated by the sympathetic and parasympathetic nervous system; therefore, it may serve as a biomarker of stress. To assess the associations between the cognitive and emotional dimensions of exam stress and pH levels, and the predictability of salivary pH in relation to test performance. A prospective study. Eighty-three nursing students answered a questionnaire on stress appraisals, experienced stress, test anxiety (including worry and emotionality subscales) and health behaviors, and gave a saliva sample for measuring pH on the morning of their first term exam and three months later. Their performance on the test (grades) was also recorded. Levels of pH in saliva were higher (levels of acidity were lower) in the post exam compared to the exam period, in parallel to lower threat appraisal, experienced stress, and test anxiety levels post exam. Controlling for smoking, physical activity and working hours per week, pH levels at both time points were predicted by appraised threat regarding the exam situation, experienced stress, and the emotionality dimension of test anxiety. pH at Time 1 predicted performance on the exams and mediated the associations of experienced stress and emotionality subscale with test performance. the present study indicates that pH levels may serve as a reliable, accessible and inexpensive means by which to assess the degree of physiological reactions to exams and other naturalistic stressors. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Peripheral Quantitative CT (pQCT) Using a Dedicated Extremity Cone-Beam CT Scanner

    PubMed Central

    Muhit, A. A.; Arora, S.; Ogawa, M.; Ding, Y.; Zbijewski, W.; Stayman, J. W.; Thawait, G.; Packard, N.; Senn, R.; Yang, D.; Yorkston, J.; Bingham, C.O.; Means, K.; Carrino, J. A.; Siewerdsen, J. H.

    2014-01-01

    Purpose We describe the initial assessment of the peripheral quantitative CT (pQCT) imaging capabilities of a cone-beam CT (CBCT) scanner dedicated to musculoskeletal extremity imaging. The aim is to accurately measure and quantify bone and joint morphology using information automatically acquired with each CBCT scan, thereby reducing the need for a separate pQCT exam. Methods A prototype CBCT scanner providing isotropic, sub-millimeter spatial resolution and soft-tissue contrast resolution comparable or superior to standard multi-detector CT (MDCT) has been developed for extremity imaging, including the capability for weight-bearing exams and multi-mode (radiography, fluoroscopy, and volumetric) imaging. Assessment of pQCT performance included measurement of bone mineral density (BMD), morphometric parameters of subchondral bone architecture, and joint space analysis. Measurements employed phantoms, cadavers, and patients from an ongoing pilot study imaged with the CBCT prototype (at various acquisition, calibration, and reconstruction techniques) in comparison to MDCT (using pQCT protocols for analysis of BMD) and micro-CT (for analysis of subchondral morphometry). Results The CBCT extremity scanner yielded BMD measurement within ±2–3% error in both phantom studies and cadaver extremity specimens. Subchondral bone architecture (bone volume fraction, trabecular thickness, degree of anisotropy, and structure model index) exhibited good correlation with gold standard micro-CT (error ~5%), surpassing the conventional limitations of spatial resolution in clinical MDCT scanners. Joint space analysis demonstrated the potential for sensitive 3D joint space mapping beyond that of qualitative radiographic scores in application to non-weight-bearing versus weight-bearing lower extremities and assessment of phalangeal joint space integrity in the upper extremities. Conclusion The CBCT extremity scanner demonstrated promising initial results in accurate pQCT analysis from

  6. An evaluation of automatic coronary artery calcium scoring methods with cardiac CT using the orCaScore framework.

    PubMed

    Wolterink, Jelmer M; Leiner, Tim; de Vos, Bob D; Coatrieux, Jean-Louis; Kelm, B Michael; Kondo, Satoshi; Salgado, Rodrigo A; Shahzad, Rahil; Shu, Huazhong; Snoeren, Miranda; Takx, Richard A P; van Vliet, Lucas J; van Walsum, Theo; Willems, Tineke P; Yang, Guanyu; Zheng, Yefeng; Viergever, Max A; Išgum, Ivana

    2016-05-01

    The amount of coronary artery calcification (CAC) is a strong and independent predictor of cardiovascular disease (CVD) events. In clinical practice, CAC is manually identified and automatically quantified in cardiac CT using commercially available software. This is a tedious and time-consuming process in large-scale studies. Therefore, a number of automatic methods that require no interaction and semiautomatic methods that require very limited interaction for the identification of CAC in cardiac CT have been proposed. Thus far, a comparison of their performance has been lacking. The objective of this study was to perform an independent evaluation of (semi)automatic methods for CAC scoring in cardiac CT using a publicly available standardized framework. Cardiac CT exams of 72 patients distributed over four CVD risk categories were provided for (semi)automatic CAC scoring. Each exam consisted of a noncontrast-enhanced calcium scoring CT (CSCT) and a corresponding coronary CT angiography (CCTA) scan. The exams were acquired in four different hospitals using state-of-the-art equipment from four major CT scanner vendors. The data were divided into 32 training exams and 40 test exams. A reference standard for CAC in CSCT was defined by consensus of two experts following a clinical protocol. The framework organizers evaluated the performance of (semi)automatic methods on test CSCT scans, per lesion, artery, and patient. Five (semi)automatic methods were evaluated. Four methods used both CSCT and CCTA to identify CAC, and one method used only CSCT. The evaluated methods correctly detected between 52% and 94% of CAC lesions with positive predictive values between 65% and 96%. Lesions in distal coronary arteries were most commonly missed and aortic calcifications close to the coronary ostia were the most common false positive errors. The majority (between 88% and 98%) of correctly identified CAC lesions were assigned to the correct artery. Linearly weighted Cohen's kappa

  7. Advances in cardiac CT contrast injection and acquisition protocols.

    PubMed

    Scholtz, Jan-Erik; Ghoshhajra, Brian

    2017-10-01

    Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors.

  8. Advances in cardiac CT contrast injection and acquisition protocols

    PubMed Central

    Scholtz, Jan-Erik

    2017-01-01

    Cardiac computed tomography (CT) imaging has become an important part of modern cardiovascular care. Coronary CT angiography (CTA) is the first choice imaging modality for non-invasive visualization of coronary artery stenosis. In addition, cardiac CT does not only provide anatomical evaluation, but also functional and valvular assessment, and myocardial perfusion evaluation. In this article we outline the factors which influence contrast enhancement, give an overview of current contrast injection and acquisition protocols, with focus on current emerging topics such as pre-transcatheter aortic valve replacement (TAVR) planning, cardiac CT for congenital heart disease (CHD) patients, and myocardial CT perfusion (CTP). Further, we point out areas where we see potential for future improvements in cardiac CT imaging based on a closer interaction between CT scanner settings and contrast injection protocols to tailor injections to patient- and exam-specific factors. PMID:29255688

  9. SU-E-P-08: Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, H; Wang, Y; Weng, H

    Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the localmore » diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan.« less

  10. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % inmore » drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.« less

  11. Age- and gender-specific estimates of cumulative CT dose over 5 years using real radiation dose tracking data in children.

    PubMed

    Lee, Eunsol; Goo, Hyun Woo; Lee, Jae-Yeong

    2015-08-01

    It is necessary to develop a mechanism to estimate and analyze cumulative radiation risks from multiple CT exams in various clinical scenarios in children. To identify major contributors to high cumulative CT dose estimates using actual dose-length product values collected for 5 years in children. Between August 2006 and July 2011 we reviewed 26,937 CT exams in 13,803 children. Among them, we included 931 children (median age 3.5 years, age range 0 days-15 years; M:F = 533:398) who had 5,339 CT exams. Each child underwent at least three CT scans and had accessible radiation dose reports. Dose-length product values were automatically extracted from DICOM files and we used recently updated conversion factors for age, gender, anatomical region and tube voltage to estimate CT radiation dose. We tracked the calculated CT dose estimates to obtain a 5-year cumulative value for each child. The study population was divided into three groups according to the cumulative CT dose estimates: high, ≥30 mSv; moderate, 10-30 mSv; and low, <10 mSv. We reviewed clinical data and CT protocols to identify major contributors to high and moderate cumulative CT dose estimates. Median cumulative CT dose estimate was 5.4 mSv (range 0.5-71.1 mSv), and median number of CT scans was 4 (range 3-36). High cumulative CT dose estimates were most common in children with malignant tumors (57.9%, 11/19). High frequency of CT scans was attributed to high cumulative CT dose estimates in children with ventriculoperitoneal shunt (35 in 1 child) and malignant tumors (range 18-49). Moreover, high-dose CT protocols, such as multiphase abdomen CT (median 4.7 mSv) contributed to high cumulative CT dose estimates even in children with a low number of CT scans. Disease group, number of CT scans, and high-dose CT protocols are major contributors to higher cumulative CT dose estimates in children.

  12. SU-F-207-02: Use of Postmortem Subjects for Subjective Image Quality Assessment in Abdominal CT Protocols with Iterative Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mench, A; Lipnharski, I; Carranza, C

    Purpose: New radiation dose reduction technologies are emerging constantly in the medical imaging field. The latest of these technologies, iterative reconstruction (IR) in CT, presents the ability to reduce dose significantly and hence provides great opportunity for CT protocol optimization. However, without effective analysis of image quality, the reduction in radiation exposure becomes irrelevant. This work explores the use of postmortem subjects as an image quality assessment medium for protocol optimizations in abdominal CT. Methods: Three female postmortem subjects were scanned using the Abdomen-Pelvis (AP) protocol at reduced minimum tube current and target noise index (SD) settings of 12.5, 17.5,more » 20.0, and 25.0. Images were reconstructed using two strengths of iterative reconstruction. Radiologists and radiology residents from several subspecialties were asked to evaluate 8 AP image sets including the current facility default scan protocol and 7 scans with the parameters varied as listed above. Images were viewed in the soft tissue window and scored on a 3-point scale as acceptable, borderline acceptable, and unacceptable for diagnosis. The facility default AP scan was identified to the reviewer while the 7 remaining AP scans were randomized and de-identified of acquisition and reconstruction details. The observers were also asked to comment on the subjective image quality criteria they used for scoring images. This included visibility of specific anatomical structures and tissue textures. Results: Radiologists scored images as acceptable or borderline acceptable for target noise index settings of up to 20. Due to the postmortem subjects’ close representation of living human anatomy, readers were able to evaluate images as they would those of actual patients. Conclusion: Postmortem subjects have already been proven useful for direct CT organ dose measurements. This work illustrates the validity of their use for the crucial evaluation of image

  13. Feasibility Study of Using Gemstone Spectral Imaging (GSI) and Adaptive Statistical Iterative Reconstruction (ASIR) for Reducing Radiation and Iodine Contrast Dose in Abdominal CT Patients with High BMI Values.

    PubMed

    Zhu, Zheng; Zhao, Xin-ming; Zhao, Yan-feng; Wang, Xiao-yi; Zhou, Chun-wu

    2015-01-01

    To prospectively investigate the effect of using Gemstone Spectral Imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. 26 patients (weight > 65kg and BMI ≥ 22) underwent abdominal CT using GSI mode with 300mgI/kg contrast material as study group (group A). Another 21 patients (weight ≤ 65kg and BMI ≥ 22) were scanned with a conventional 120 kVp tube voltage for noise index (NI) of 11 with 450mgI/kg contrast material as control group (group B). GSI images were reconstructed at 60keV with 50%ASIR and the conventional 120kVp images were reconstructed with FBP reconstruction. The CT values, standard deviation (SD), signal-noise-ratio (SNR), contrast-noise-ratio (CNR) of 26 landmarks were quantitatively measured and image quality qualitatively assessed using statistical analysis. As for the quantitative analysis, the difference of CNR between groups A and B was all significant except for the mesenteric vein. The SNR in group A was higher than B except the mesenteric artery and splenic artery. As for the qualitative analysis, all images had diagnostic quality and the agreement for image quality assessment between the reviewers was substantial (kappa = 0.684). CT dose index (CTDI) values for non-enhanced, arterial phase and portal phase in group A were decreased by 49.04%, 40.51% and 40.54% compared with group B (P = 0.000), respectively. The total dose and the injection rate for the contrast material were reduced by 14.40% and 14.95% in A compared with B. The use of GSI and ASIR provides similar enhancement in vessels and image quality with reduced radiation dose and contrast dose, compared with the use of conventional scan protocol.

  14. X-Ray Exam: Hip

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What ... Have Questions Print What It Is A hip X-ray is a safe and painless test that ...

  15. X-Ray Exam: Forearm

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: Forearm What's in this article? What ... Have Questions Print What It Is A forearm X-ray is a safe and painless test that ...

  16. X-Ray Exam: Ankle

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What ... Have Questions Print What It Is An ankle X-ray is a safe and painless test that ...

  17. X-Ray Exam: Foot

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: Foot What's in this article? What ... Have Questions Print What It Is A foot X-ray is a safe and painless test that ...

  18. X-Ray Exam: Wrist

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: Wrist What's in this article? What ... Have Questions Print What It Is A wrist X-ray is a safe and painless test that ...

  19. X-Ray Exam: Finger

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: Finger What's in this article? What ... Have Questions Print What It Is A finger X-ray is a safe and painless test that ...

  20. X-Ray Exam: Pelvis

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: Pelvis What's in this article? What ... Have Questions Print What It Is A pelvis X-ray is a safe and painless test that ...

  1. SU-F-J-169: A Feasibility Study of Using MRI Alone in Abdominal Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zawisza, I; Hsu, S; Peng, Q

    Purpose: To demonstrate the feasibility of a MRI alone workflow to support treatment planning and image guidance for abdominal radiotherapy. Methods: Abdominal MR images (in-phase/out-phase/fat/water) were acquired for a patient with breath-hold using a Dixon pulse sequence. Air masks were created on in-phase images using intensity thresholding and morphological processing methods in order to separate air from bone. Pseudo-CT and DRRs were generated using a published method. To investigate the effect of heterogeneity corrections on dose calculations using pseudo-CT, three different plans (3-field 3D, 5-field IMRT and 2-arc VMAT) were performed to mimic pancreatic treatments (1.8Gy/fraction over 28 fractions). Results:more » The DRRs created from pseudo-CT were of comparable quality as those created from CT. Comparing dose calculations with and without heterogeneity corrections between the 3 different plans, the biggest dosimetric differences were seen in the VMAT plan where modulation must occur across air-tissue interfaces such as those of the stomach and bowel. The DVHs for the VMAT plan showed ∼84cc difference at V50Gy in the small bowel. In terms of pseudo-CT quality, some small volumes of air in the bowel and stomach were misclassified as bone. The VMAT plan was re-optimized on pseudo-CT with 0 HU in the misclassified areas. The V50Gy in the small bowel differed by ∼90cc between the new VMAT plan with and without heterogeneity corrections. Conclusion: We found that the use of MRI alone is feasible for abdominal treatment planning and image guidance. A difference between calculations with and without heterogeneity corrections was found that is most pronounced for VMAT where the traversal of air-tissue interfaces is unavoidable. Future work will be performed to minimize misclassification between bone and air.« less

  2. Predictors of "occult" intra-abdominal injuries in blunt trauma patients.

    PubMed

    Parreira, José Gustavo; Malpaga, Juliano Mangini Dias; Olliari, Camilla Bilac; Perlingeiro, Jacqueline A G; Soldá, Silvia C; Assef, José Cesar

    2015-01-01

    to assess predictors of intra-abdominal injuries in blunt trauma patients admitted without abdominal pain or abnormalities on the abdomen physical examination. We conducted a retrospective analysis of trauma registry data, including adult blunt trauma patients admitted from 2008 to 2010 who sustained no abdominal pain or abnormalities on physical examination of the abdomen at admission and were submitted to computed tomography of the abdomen and/or exploratory laparotomy. Patients were assigned into: Group 1 (with intra-abdominal injuries) or Group 2 (without intra-abdominal injuries). Variables were compared between groups to identify those significantly associated with the presence of intra-abdominal injuries, adopting p<0.05 as significant. Subsequently, the variables with p<0.20 on bivariate analysis were selected to create a logistic regression model using the forward stepwise method. A total of 268 cases met the inclusion criteria. Patients in Group I were characterized as having significantly (p<0.05) lower mean AIS score for the head segment (1.0 ± 1.4 vs. 1.8 ± 1.9), as well as higher mean AIS thorax score (1.6 ± 1.7 vs. 0.9 ± 1.5) and ISS (25.7 ± 14.5 vs. 17,1 ± 13,1). The rate of abdominal injuries was significantly higher in run-over pedestrians (37.3%) and in motorcyclists (36.0%) (p<0.001). The resultant logistic regression model provided 73.5% accuracy for identifying abdominal injuries. The variables included were: motorcyclist accident as trauma mechanism (p<0.001 - OR 5.51; 95%CI 2.40-12.64), presence of rib fractures (p<0.003 - OR 3.00; 95%CI 1.47-6.14), run-over pedestrian as trauma mechanism (p=0.008 - OR 2.85; 95%CI 1.13-6.22) and abnormal neurological physical exam at admission (p=0.015 - OR 0.44; 95%CI 0.22-0.85). Intra-abdominal injuries were predominantly associated with trauma mechanism and presence of chest injuries.

  3. Recurrent Scapular Metastasis From Hepatoblastoma Shown on FDG PET/CT and F-DOPA PET/CT.

    PubMed

    Zhang, Bing; He, Qiao; Shi, Xinchong; Wang, Xiaoyan; Zhang, Xiangsong

    2017-10-01

    We report the case of a 4-year-old girl with a biochemical relapse (plasma α-fetoprotein of 57,987.6 μg/L) after hepatoblastoma and extrahepatic metastases removal and adjuvant chemotherapy. Abdominal ultrasound, CT, and MRI failed to determine the site of recurrence. F-FDG PET/CT showed increased activity in the region of left scapula and adjacent soft tissue, which was incorrectly interpreted as the postoperative repair or inflammatory change. F-DOPA PET/CT showed increased activity and noticeable progressed lesion in the same place. Finally, the left scapula was identified as the site of recurrent metastasis from hepatoblastoma by pathological examination.

  4. Non-contrast CT at comparable dose to an abdominal radiograph in patients with acute renal colic; impact of iterative reconstruction on image quality and diagnostic performance.

    PubMed

    McLaughlin, P D; Murphy, K P; Hayes, S A; Carey, K; Sammon, J; Crush, L; O'Neill, F; Normoyle, B; McGarrigle, A M; Barry, J E; Maher, M M

    2014-04-01

    The aim was to assess the performance of low-dose non-contrast CT of the urinary tract (LD-CT) acquired at radiation exposures close to that of abdominal radiography using adaptive statistical iterative reconstruction (ASiR). Thirty-three patients with clinically suspected renal colic were prospectively included. Conventional dose (CD-CT) and LD-CT data sets were contemporaneously acquired. LD-CT images were reconstructed with 40 %, 70 % and 90 % ASiR. Image quality was subjectively and objectively measured. Images were also clinically interpreted. Mean ED was 0.48 ± 0.07 mSv for LD-CT compared with 4.43 ± 3.14 mSv for CD-CT. Increasing the percentage ASiR resulted in a step-wise reduction in mean objective noise (p < 0.001 for all comparisons). Seventy % ASiR LD-CT images had higher diagnostic acceptability and spatial resolution than 90 % ASiR LD-CT images (p < 0.001). Twenty-seven calculi (diameter = 5.5 ± 1.7 mm), including all ureteric stones, were correctly identified using 70 % ASiR LD-CT with two false positives and 16 false negatives (diameter = 2.3 ± 0.7 mm) equating to a sensitivity and specificity of 72 % and 94 %. Seventy % ASiR LD-CT had a sensitivity and specificity of 87 % and 100 % for detection of calculi >3 mm. Reconstruction of LD-CT images with 70 % ASiR resulted in superior image quality than FBP, 40 % ASIR and 90 % ASIR. LD-CT with ASIR demonstrates high sensitivity and specificity for detection of calculi >3 mm. • Low-dose CT studies for urinary calculus detection were performed with a mean dose of 0.48 ± 0.07 mSv • Low-dose CT with 70 % ASiR detected calculi >3 mm with a sensitivity and specificity of 87 % and 100 % • Reconstruction with 70 % ASiR was superior to filtered back projection, 40 % ASiR and 90 % ASiR images.

  5. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors

    PubMed Central

    Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun

    2017-01-01

    Background: Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Methods: Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images <60 keV in Group A. The total radiation dose, total iodine load, contrast injection speed, and maximum injection pressure were compared between the two groups. The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality. Results: The total radiation dose, total iodine load, injection speed, and maximum injection pressure for Group A were decreased by 19%, 15%, 34.4%, and 18.3%, respectively. The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV. At this level, the CT values in the abdominal aorta and its three branches, the portal vein and its two branches, and the inferior vena cava were all greater than 340 hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0

  6. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors.

    PubMed

    Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun

    2017-04-05

    Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images <60 keV in Group A. The total radiation dose, total iodine load, contrast injection speed, and maximum injection pressure were compared between the two groups. The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality. The total radiation dose, total iodine load, injection speed, and maximum injection pressure for Group A were decreased by 19%, 15%, 34.4%, and 18.3%, respectively. The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV. At this level, the CT values in the abdominal aorta and its three branches, the portal vein and its two branches, and the inferior vena cava were all greater than 340 hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and -1.716 for liver, -0.153 and

  7. Improving the preparticipation exam process.

    PubMed

    Reed, F E

    2001-08-01

    The Preparticipation Exam for too long has been a mandatory yearly athletic exam and not the base from which a process of continuous athletic care took place. The purpose of this article is not only to introduce improvements in the exam itself but to also describe some extensions of the process that allow us to improve athletic care in South Carolina. It is hoped that a software scanning program will allow compiling of demographic data from individual and group examinations and thus support the method of exam preferred by all physicians in our state. Standard forms will also facilitate communication within the Athletic Care Unit and between physicians involved in athletic care.

  8. Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach

    PubMed Central

    Tong, Yubing; Udupa, Jayaram K.; Torigian, Drew A.

    2014-01-01

    Purpose: The quantification of body fat plays an important role in the study of numerous diseases. It is common current practice to use the fat area at a single abdominal computed tomography (CT) slice as a marker of the body fat content in studying various disease processes. This paper sets out to answer three questions related to this issue which have not been addressed in the literature. At what single anatomic slice location do the areas of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated from the slice correlate maximally with the corresponding fat volume measures? How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? Are there combinations of multiple slices (not necessarily contiguous) whose area sum correlates better with volume than does single slice area with volume? Methods: The authors propose a novel strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. The authors then study the volume-to-area correlations and determine where they become maximal. To address the third issue, the authors carry out similar correlation studies by utilizing two and three slices for calculating area sum. Results: Based on 50 abdominal CT data sets, the proposed mapping achieves significantly improved consistency of anatomic localization compared to current practice. Maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized currently for single slice area estimation as a marker. Conclusions: The maximum area-to-volume correlation achieved is quite high, suggesting that it may be reasonable to estimate body fat by measuring the area of fat from a single anatomic slice at the site of maximum correlation and use this as a marker. The site of maximum correlation is not at L4-L5 as commonly assumed

  9. Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tong, Yubing; Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu; Torigian, Drew A.

    Purpose: The quantification of body fat plays an important role in the study of numerous diseases. It is common current practice to use the fat area at a single abdominal computed tomography (CT) slice as a marker of the body fat content in studying various disease processes. This paper sets out to answer three questions related to this issue which have not been addressed in the literature. At what single anatomic slice location do the areas of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated from the slice correlate maximally with the corresponding fat volume measures? How doesmore » one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? Are there combinations of multiple slices (not necessarily contiguous) whose area sum correlates better with volume than does single slice area with volume? Methods: The authors propose a novel strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. The authors then study the volume-to-area correlations and determine where they become maximal. To address the third issue, the authors carry out similar correlation studies by utilizing two and three slices for calculating area sum. Results: Based on 50 abdominal CT data sets, the proposed mapping achieves significantly improved consistency of anatomic localization compared to current practice. Maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized currently for single slice area estimation as a marker. Conclusions: The maximum area-to-volume correlation achieved is quite high, suggesting that it may be reasonable to estimate body fat by measuring the area of fat from a single anatomic slice at the site of maximum correlation and use this as a marker. The site of maximum correlation is not at L4-L5 as commonly

  10. Seatbelt sign in a case of blunt abdominal trauma; what lies beneath it?

    PubMed

    Vailas, Michail G; Moris, Demetrios; Orfanos, Stamatios; Vergadis, Chrysovalantis; Papalampros, Alexandros

    2015-10-30

    The reported incidence of hollow viscus injuries (HVI) in blunt trauma patients is approximately 1%. The most common site of injury to the intestine in blunt abdominal trauma (BAT) is the small bowel followed by colon, with mesenteric injuries occurring three times more commonly than bowel injuries. Isolated colon injury is a rarely encountered condition. Clinical assessment alone in patients with suspected intestinal or mesenteric injury after blunt trauma is associated with unacceptable diagnostic delays. This is a case of a 31-year-old man, admitted to the emergency department after being the restrained driver, involved in a car accident. After initial resuscitation, focused assessment with sonography for trauma examination (FAST) was performed revealing a subhepatic mass, suspicious for intraperitoneal hematoma. A computed tomography scan (CT) that followed showed a hematoma of the mesocolon of the ascending colon with active extravasation of intravenous contrast material. An exploratory laparotomy was performed, hemoperitomeum was evacuated, and a subserosal hematoma of the cecum and ascending colon with areas of totally disrupted serosal wall was found. Hematoma of the adjacent mesocolon expanding to the root of mesenteric vessels was also noted. A right hemicolectomy along with primary ileocolonic anastomosis was performed. Patient's recovery progressed uneventfully. Identifying an isolated traumatic injury to the bowel or mesentery after BAT can be a clinical challenge because of its subtle and nonspecific clinical findings; meeting that challenge may eventually lead to a delay in diagnosis and treatment with subsequent increase in associated morbidity and mortality. Isolated colon injury is a rare finding after blunt trauma and usually accompanied by other intra-abdominal organ injuries. Abdominal 'seatbelt' sign, ecchymosis of the abdominal wall, increasing abdominal pain and distension are all associated with HVI. However, the accuracy of these findings

  11. Intra-abdominal drain fracture following pancreatic necrosectomy.

    PubMed

    Campbell, W; Wallace, W; Gibson, E; McCallion, K

    2011-06-01

    We describe a rare case of iatrogenic fracture of an intra-abdominal tube drain (Portex Robinson drain, Smiths Medical, Kent, UK) in a 74-year-old man. The fracture occurred at the level of an additionally placed fenestration and was identified on CT scanning prior to retrieval at planned re-laparotomy. This case highlights the potential dangers of modifying pre-formed drains and recommends against this practice.

  12. Systematic review on the value of CT scanning in the diagnosis of anastomotic leakage after colorectal surgery.

    PubMed

    Kornmann, Verena N N; Treskes, Nikki; Hoonhout, Lilian H F; Bollen, Thomas L; van Ramshorst, Bert; Boerma, Djamila

    2013-04-01

    Timely diagnosis of anastomotic leakage after colorectal surgery and adequate treatment is important to reduce morbidity and mortality. Abdominal computed tomography (CT) scanning is the diagnostic tool of preference, but its value may be questionable in the early postoperative period. The accuracy of CT scanning for the detection of anastomotic leakage and its role in timing of intervention was evaluated. A systematic literature search was performed. Relevant publications were identified from four electronic databases between 1990 and 2011. Inclusion criteria were human studies, studies published in English or Dutch, colorectal surgery with primary anastomosis, and abdominal CT scan with reported outcome for the detection of anastomotic leakage. Exclusion criteria were cohort of fewer than five patients, other gastrointestinal surgery, no anastomosis, and radiological imaging other than CT. Eight studies, including 221 abdominal CT scans, fulfilled the inclusion criteria. Overall, the methodological quality of the studies was poor. The overall sensitivity of CT scanning to diagnose leakage was 0.68 (95 % confidence interval 0.59-0.75) for colonic resection. Data on the sequelae of false-negative CT scanning was not available. There is limited good-quality evidence to determine the value of CT scans in the detection of anastomotic leakage. To prevent delay in diagnosis and appropriate treatment of anastomotic leakage, the relatively low sensitivity of CT scanning must be taken into account.

  13. Data-driven CT protocol review and management—experience from a large academic hospital.

    PubMed

    Zhang, Da; Savage, Cristy A; Li, Xinhua; Liu, Bob

    2015-03-01

    Protocol review plays a critical role in CT quality assurance, but large numbers of protocols and inconsistent protocol names on scanners and in exam records make thorough protocol review formidable. In this investigation, we report on a data-driven cataloging process that can be used to assist in the reviewing and management of CT protocols. We collected lists of scanner protocols, as well as 18 months of recent exam records, for 10 clinical scanners. We developed computer algorithms to automatically deconstruct the protocol names on the scanner and in the exam records into core names and descriptive components. Based on the core names, we were able to group the scanner protocols into a much smaller set of "core protocols," and to easily link exam records with the scanner protocols. We calculated the percentage of usage for each core protocol, from which the most heavily used protocols were identified. From the percentage-of-usage data, we found that, on average, 18, 33, and 49 core protocols per scanner covered 80%, 90%, and 95%, respectively, of all exams. These numbers are one order of magnitude smaller than the typical numbers of protocols that are loaded on a scanner (200-300, as reported in the literature). Duplicated, outdated, and rarely used protocols on the scanners were easily pinpointed in the cataloging process. The data-driven cataloging process can facilitate the task of protocol review. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  14. Intra-Abdominal Hypertension and Abdominal Compartment Syndrome after Abdominal Wall Reconstruction: Quaternary Syndromes?

    PubMed

    Kirkpatrick, A W; Nickerson, D; Roberts, D J; Rosen, M J; McBeth, P B; Petro, C C; Berrevoet, Frederik; Sugrue, M; Xiao, Jimmy; Ball, C G

    2017-06-01

    Reconstruction with reconstitution of the container function of the abdominal compartment is increasingly being performed in patients with massive ventral hernia previously deemed inoperable. This situation places patients at great risk of severe intra-abdominal hypertension and abdominal compartment syndrome if organ failure ensues. Intra-abdominal hypertension and especially abdominal compartment syndrome may be devastating systemic complications with systematic and progressive organ failure and death. We thus reviewed the pathophysiology and reported clinical experiences with abnormalities of intra-abdominal pressure in the context of abdominal wall reconstruction. Bibliographic databases (1950-2015), websites, textbooks, and the bibliographies of previously recovered articles for reports or data relating to intra-abdominal pressure, intra-abdominal hypertension, and the abdominal compartment syndrome in relation to ventral, incisional, or abdominal hernia repair or abdominal wall reconstruction. Surgeons should thus consider and carefully measure intra-abdominal pressure and its resultant effects on respiratory parameters and function during abdominal wall reconstruction. The intra-abdominal pressure post-operatively will be a result of the new intra-peritoneal volume and the abdominal wall compliance. Strategies surgeons may utilize to ameliorate intra-abdominal pressure rise after abdominal wall reconstruction including temporizing paralysis of the musculature either temporarily or semi-permanently, pre-operative progressive pneumoperitoneum, permanently removing visceral contents, or surgically releasing the musculature to increase the abdominal container volume. In patients without complicating shock and inflammation, and in whom the abdominal wall anatomy has been so functionally adapted to maximize compliance, intra-abdominal hypertension may be transient and tolerable. Intra-abdominal hypertension/abdominal compartment syndrome in the specific setting of

  15. French Women From Multiplex Abdominal Aortic Aneurysm Families Should Be Screened

    PubMed Central

    Le Hello, Claire; Koskas, Fabien; Cluzel, Philippe; Tazi, Zoubida; Gallos, Corina; Piette, Jean Charles; Lasserve, Elisabeth Tournier; Kieffer, Edouard; Cacoub, Patrice

    2005-01-01

    Background: Multiplex abdominal aortic aneurysm families (MAAAFs) (≥1 subject plus the proband) represent 1% to 34% of abdominal aortic aneurysm (AAA), but the percentage in France is unknown. Method: The MAAAF rate was retrospectively defined by analysis of 3 groups: 72 of 104 consecutive individuals undergoing AAA surgery during 1994, 24 of 53 women and 35 of 76 men with giant (≥9 cm) AAA operated on during 1986 to 1994. MAAAF characteristics were determined based on 10 families issued from these 3 groups and 34 others identified nationwide. Data were obtained from a standardized questionnaire for probands and relatives, detailed pedigrees of each family, and computed tomography (CT) scans without contrast medium of the aorta and lower limb arteries for first-degree relatives ≥40-year-of age. Results: The MAAAF rate was 4.2% for the consecutive-surgery patients (proband M/F ratio, 17:1; mean age at surgery, 68.5 ± 8.5 years). CT detected no additional AAA among them (screened individuals M/F ratio, 0.63; mean age, 54.0 ± 11.2 years). MAAAF rates were 8.3% and 14.3% for the women's and giant-AAA groups with CT screening, respectively. Characteristics were investigated in 104 affected subjects from 44 MAAAFs: female relatives were more often affected than probands (P < 0.025). Compared with men, affected female relatives were significantly older at diagnosis and surgery (P < 0.05 and P < 0.02, respectively), as were affected women (P < 0.02 and P < 0.01, respectively). CT scan screening identified significantly more AAA and abdominal aortic dilatations among the 44 MAAAFs than the consecutive-surgery group (5 and 4, respectively; P < 0.001). Conclusion: Although the MAAAF rate seems low in France, women from MAAAF were affected more often and later, suggesting that they should be screened. PMID:16244549

  16. X-ray dose reduction in abdominal computed tomography using advanced iterative reconstruction algorithms.

    PubMed

    Ning, Peigang; Zhu, Shaocheng; Shi, Dapeng; Guo, Ying; Sun, Minghua

    2014-01-01

    This work aims to explore the effects of adaptive statistical iterative reconstruction (ASiR) and model-based iterative reconstruction (MBIR) algorithms in reducing computed tomography (CT) radiation dosages in abdominal imaging. CT scans on a standard male phantom were performed at different tube currents. Images at the different tube currents were reconstructed with the filtered back-projection (FBP), 50% ASiR and MBIR algorithms and compared. The CT value, image noise and contrast-to-noise ratios (CNRs) of the reconstructed abdominal images were measured. Volumetric CT dose indexes (CTDIvol) were recorded. At different tube currents, 50% ASiR and MBIR significantly reduced image noise and increased the CNR when compared with FBP. The minimal tube current values required by FBP, 50% ASiR, and MBIR to achieve acceptable image quality using this phantom were 200, 140, and 80 mA, respectively. At the identical image quality, 50% ASiR and MBIR reduced the radiation dose by 35.9% and 59.9% respectively when compared with FBP. Advanced iterative reconstruction techniques are able to reduce image noise and increase image CNRs. Compared with FBP, 50% ASiR and MBIR reduced radiation doses by 35.9% and 59.9%, respectively.

  17. Balancing Radiation and Contrast Media Dose in Single-Pass Abdominal Multidetector CT: Prospective Evaluation of Image Quality.

    PubMed

    Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo

    2015-11-01

    As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P < .001) for groups A, B, and C, respectively, no significant differences were observed in the corresponding SNRL with 9.2 ± 1.4, 9.1 ± 1.2, and 9.2 ± 3. Radiation (mGy × cm) and contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P < .001). None of the studies was graded as poor or inadequate by both readers, and the prevalence-adjusted bias-adjusted kappa ranged between 0.48 and 0.93 for all but one criteria. A constant image quality in CE-MDCT can be obtained balancing radiation and contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  18. In vivo 3D PIXE-micron-CT imaging of Drosophila melanogaster using a contrast agent

    NASA Astrophysics Data System (ADS)

    Matsuyama, Shigeo; Hamada, Naoki; Ishii, Keizo; Nozawa, Yuichiro; Ohkura, Satoru; Terakawa, Atsuki; Hatori, Yoshinobu; Fujiki, Kota; Fujiwara, Mitsuhiro; Toyama, Sho

    2015-04-01

    In this study, we developed a three-dimensional (3D) computed tomography (CT) in vivo imaging system for imaging small insects with micrometer resolution. The 3D CT imaging system, referred to as 3D PIXE-micron-CT (PIXEμCT), uses characteristic X-rays produced by ion microbeam bombardment of a metal target. PIXEμCT was used to observe the body organs and internal structure of a living Drosophila melanogaster. Although the organs of the thorax were clearly imaged, the digestive organs in the abdominal cavity could not be clearly discerned initially, with the exception of the rectum and the Malpighian tubule. To enhance the abdominal images, a barium sulfate powder radiocontrast agent was added. For the first time, 3D images of the ventriculus of a living D. melanogaster were obtained. Our results showed that PIXEμCT can provide in vivo 3D-CT images that reflect correctly the structure of individual living organs, which is expected to be very useful in biological research.

  19. [Adult transient intestinal intussusception: can abdominal CT guide resolution?].

    PubMed

    Stabile Ianora, Amato Antonio; Telegrafo, Michele; Lorusso, Valentina; Rella, Leonarda; Niccoli Asabella, Artor; La Porta, Michele; Moschetta, Marco

    2013-01-01

    The purpose of this study was to evaluate the adult transient intestinal intussusceptions on CT before and after the administration of gastrointestinal contrast material. We evaluated two different gastrointestinal contrast materials: hyperdense and hypodense. In all cases the gastrointestinal contrast agent solved the invaginations. In the group of patients treated with hypodense contrast medium relapses occurred in the short and long term; no recurrence was observed in the other group. CT is useful in the recognition of intestinal intussusception. The gastrointestinal contrast agent could define the real transience of intussusceptions and hyperdense contrast agent could be more effective in short and long term resolution.

  20. Can CT and MR Shape and Textural Features Differentiate Benign Versus Malignant Pleural Lesions?

    PubMed

    Pena, Elena; Ojiaku, MacArinze; Inacio, Joao R; Gupta, Ashish; Macdonald, D Blair; Shabana, Wael; Seely, Jean M; Rybicki, Frank J; Dennie, Carole; Thornhill, Rebecca E

    2017-10-01

    The study aimed to identify a radiomic approach based on CT and or magnetic resonance (MR) features (shape and texture) that may help differentiate benign versus malignant pleural lesions, and to assess if the radiomic model may improve confidence and accuracy of radiologists with different subspecialty backgrounds. Twenty-nine patients with pleural lesions studied on both contrast-enhanced CT and MR imaging were reviewed retrospectively. Three texture and three shape features were extracted. Combinations of features were used to generate logistic regression models using histopathology as outcome. Two thoracic and two abdominal radiologists evaluated their degree of confidence in malignancy. Diagnostic accuracy of radiologists was determined using contingency tables. Cohen's kappa coefficient was used to assess inter-reader agreement. Using optimal threshold criteria, sensitivity, specificity, and accuracy of each feature and combination of features were obtained and compared to the accuracy and confidence of radiologists. The CT model that best discriminated malignant from benign lesions revealed an AUC CT  = 0.92 ± 0.05 (P < 0.0001). The most discriminative MR model showed an AUC MR  = 0.87 ± 0.09 (P < 0.0001). The CT model was compared to the diagnostic confidence of all radiologists and the model outperformed both abdominal radiologists (P < 0.002), whereas the top discriminative MR model outperformed one of the abdominal radiologists (P = 0.02). The most discriminative MR model was more accurate than one abdominal (P = 0.04) and one thoracic radiologist (P = 0.02). Quantitative textural and shape analysis may help distinguish malignant from benign lesions. A radiomics-based approach may increase diagnostic confidence of abdominal radiologists on CT and MR and may potentially improve radiologists' accuracy in the assessment of pleural lesions characterized by MR. Copyright © 2017 The Association of University

  1. My Favorite Exam Question

    ERIC Educational Resources Information Center

    Styer, Dan

    2015-01-01

    My favorite exam question comes from the final exam in an introductory mechanics course: "A rolling 31 ton railroad boxcar collides with a stationary flatcar. The coupling mechanism activates so the cars latch together and roll down the track attached. Of the initial kinetic energy, 38% dissipates as heat, sound, vibrations, mechanical…

  2. Are Online Exams an Invitation to Cheat?

    ERIC Educational Resources Information Center

    Harmon, Oskar R.; Lambrinos, James; Kennedy, Peter, Ed.

    2008-01-01

    In this study, the authors use data from two online courses in principles of economics to estimate a model that predicts exam scores from independent variables of student characteristics. In one course, the final exam was proctored, and in the other course, the final exam was not proctored. In both courses, the first three exams were unproctored.…

  3. Formal reporting of second-opinion CT interpretation: experience and reimbursement in the emergency department setting.

    PubMed

    Jeffers, Adam B; Saghir, Amina; Camacho, Marc

    2012-06-01

    The purpose of this study is to describe a system for formally reporting second-opinion interpretations of CT imaging exams accompanying patients transferred emergently to a tertiary care center. Second-opinion interpretations of cross-sectional imaging exams rendered in the emergency department setting over 6 months spanning 22 September 2009 to 22 March 2010 were reviewed and tallied by two radiologists and a research assistant, with a focus on professional fee reimbursement rates. A more in depth review was performed of those exams for which a clinical referral request form was available, detailing such information as the clinical history, content and source of available initial interpretation, and congruity of the initial interpretation with clinical data. Discrepancies between outside and second-opinion interpretations were also assessed. This quality assurance exercise was reviewed by our institutional review board, which waived formal informed consent. Formal second-opinion interpretation was rendered for 370 exams on 198 patients (mean age, 53.5 years; 45.1% female), received from 50 referring facilities. Head CT was the most common imaging exam referred for second opinion. Forty-one of 370 exams (11%) were submitted for self-pay, and 43 (12%) were written off as free care. The remaining 286 exams (77%) were submitted for reimbursement of the professional fee only. Ultimately, of the 286 exams submitted, 260 (91%) were reimbursed for professional fees, 199 (70%) on the initial submission. Of 29 health plans contracted with our facility, 22 ultimately approved all claims made. Three plans denied all claims submitted. The largest payer was Medicare, which reimbursed 88 of 90 submitted claims. Clinical intake forms were available for 184 exams on 107 patients (mean age, 52.7 years, 43.0% female). Trauma was the most common indication, or history, provided (55% of 184 exams, 40% of 107 patients). An outside report of some form was available for 112 of the 184

  4. Emergency ultrasound-based algorithms for diagnosing blunt abdominal trauma.

    PubMed

    Stengel, Dirk; Rademacher, Grit; Ekkernkamp, Axel; Güthoff, Claas; Mutze, Sven

    2015-09-14

    Ultrasonography (performed by means of a four-quadrant, focused assessment of sonography for trauma (FAST)) is regarded as a key instrument for the initial assessment of patients with suspected blunt abdominal and thoraco-abdominal trauma in the emergency department setting. FAST has a high specificity but low sensitivity in detecting and excluding visceral injuries. Proponents of FAST argue that ultrasound-based clinical pathways enhance the speed of primary trauma assessment, reduce the number of unnecessary multi-detector computed tomography (MDCT) scans, and enable quicker triage to surgical and non-surgical care. Given the proven accuracy, increasing availability of, and indication for, MDCT among patients with blunt abdominal and multiple injuries, we aimed to compile the best available evidence of the use of FAST-based assessment compared with other primary trauma assessment protocols. To assess the effects of diagnostic algorithms using ultrasonography including in FAST examinations in the emergency department in relation to the early, late, and overall mortality of patients with suspected blunt abdominal trauma. The most recent search was run on 30th June 2015. We searched the Cochrane Injuries Group Specialised Register, The Cochrane Library, MEDLINE (OvidSP), EMBASE (OvidSP), ISI Web of Science (SCI-EXPANDED, SSCI, CPCI-S, and CPSI-SSH), clinical trials registers, and screened reference lists. Trial authors were contacted for further information and individual patient data. We included randomised controlled trials (RCTs). Participants were patients with blunt torso, abdominal, or multiple trauma undergoing diagnostic investigations for abdominal organ injury. The intervention was diagnostic algorithms comprising emergency ultrasonography (US). The control was diagnostic algorithms without US examinations (for example, primary computed tomography (CT) or diagnostic peritoneal lavage (DPL)). Outcomes were mortality, use of CT or invasive procedures (DPL

  5. Exit Exam as Academic Performance Indicator

    ERIC Educational Resources Information Center

    Al Ahmad, Mahmoud; Al Marzouqi, Ali H.; Hussien, Mousa

    2014-01-01

    This paper focuses on the impact of exit exams on different elements of the educational process, namely: curriculum development, students and instructors. A 50-question multiple-choice Exit Exam was prepared by Electrical Engineering (EE) faculty members covering a poll of questions from EE core courses. A copy of the Exit Exam applied during each…

  6. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    PubMed Central

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  7. Mechanical small bowel obstruction following a blunt abdominal trauma: A case report

    PubMed Central

    Zirak-Schmidt, Samira; El-Hussuna, Alaa

    2015-01-01

    Introduction Intestinal obstruction following abdominal trauma has previously been described. However, in most reported cases pathological finding was intestinal stenosis. Presentation of the case A 51-year-old male was admitted after a motor vehicle accident. Initial focused abdominal sonogram for trauma and enhanced computerized tomography were normal, however there was a fracture of the tibia. Three days later, he complained of abdominal pain, constipation, and vomiting. An exploratory laparotomy showed bleeding from the omentum and mechanical small bowel obstruction due to a fibrous band. Discussion The patient had prior abdominal surgery, but clinical and radiological findings indicate that the impact of the motor vehicle accident initiated his condition either by causing rotation of a bowel segment around the fibrous band, or by formation of a fibrous band secondary to minimal bleeding from the omentum. Conclusion High index of suspicion of intestinal obstruction is mandatory in trauma patients presenting with complaints of abdominal pain, vomiting, and constipation despite uneventful CT scan. PMID:26566436

  8. Mass screening of multiple abdominal solid organs using mobile helical computed tomography scanner--a preliminary report.

    PubMed

    Ishikawa, Susumu; Aoki, Jun; Ohwada, Susumu; Takahashi, Toru; Morishita, Yasuo; Ueda, Keisuke

    2007-04-01

    The possibility of a new screening procedure for multiple abdominal solid organs using a mobile helical computed tomography (CT) scanner was evaluated. A total of 4,543 residents, who were 40 years of age or older, received CT scanning without contrast medium. The mean age of participants was 64 years including 2,022 males and 2,521 females. A total of 2,105 abnormal findings were uniquely detected in 1,594 participants. Liver and kidney diseases including ureter occupied around 30% of total abnormal findings, respectively. Besides frequent cystic or calcified lesions, solid tumours were suspected in 56 lesions, which received further examination by specialized physicians. Five (9%) of them were confirmed as being malignant tumours including pancreatic cancer in two patients, and liver, lung and ovary cancers in one patient each, respectively. All five patients with each malignant lesion received curative operations. Small-sized abdominal aortic aneurysms and heart valve diseases were uniquely found in 22 and two patients, respectively. Qualitative diagnoses of solid tumours were difficult using CT findings without contrast medium. CT screening procedures require further investigation in aspect of the selection of examinees, CT scanning procedure, sensitivity and specificity, and cost-effectiveness.

  9. Evaluation of the radiation doses in newborn patients submitted to CT examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Souza Santos, William; Caldas, Linda V.E.; Belinato, Walmir

    The number of computed tomography (CT) scans available to the population is increasing, as well as the complexity of such exams. As a result, the radiation doses are increasing as well. Considering the population exposed to CT exams, pediatric patients are considerably more sensitive to radiation than adults. They have a longer life expectancy than adults, and may receive a higher radiation dose than necessary if the CT scan settings are not adjusted for their smaller body size. As a result of these considerations, the risk of developing cancer is of great concern when newborn patients are involved. The objectivemore » of this work was to study the radiation doses on radiosensitive organs of newborn patients undergoing a whole body CT examination, utilizing Monte Carlo simulations. The novelty of this work is the use of pediatric virtual anthropomorphic phantoms, developed at the Department of Nuclear Energy at the Federal University of Pernambuco (DEN/UFPE). The CT equipment utilized during the simulations was a Discovery VCT GE PET/CT system, with a tube voltage of 140 kVp. The X-ray spectrum of this CT scanner was generated by the SRS-78 software, which takes into account the X-ray beam energy used in PET/CT procedures. The absorbed organ doses were computed employing the F6 tally (MeV/g). The results were converted to dose coefficients (mGy/100 mA) for all the structures, considering all employed beams. The highest dose coefficients values were obtained for the brain and the thyroid. This work provides useful information regarding the risks involving ionizing radiation in newborn patients, employing a new and reliable technique. (authors)« less

  10. Unenhanced Computed Tomography to Visualize Hollow Viscera and/or Mesenteric Injury After Blunt Abdominal Trauma: A Single-Institution Experience.

    PubMed

    Yang, Xu-Yang; Wei, Ming-Tian; Jin, Cheng-Wu; Wang, Meng; Wang, Zi-Qiang

    2016-03-01

    To identify and describe the major features of unenhanced computed tomography (CT) images of blunt hollow viscera and/or mesenteric injury (BHVI/MI) and to determine the value of unenhanced CT in the diagnosis of BHVI/MI. This retrospective study included 151 patients who underwent unenhanced CT before laparotomy for blunt abdominal trauma between January 2011 and December 2013. According to surgical observations, patients were classified as having BHVI/MI (n = 73) or not (n = 78). Sensitivity, specificity, P values, and likelihood ratios were calculated by comparing CT findings between the 2 groups. Six significant CT findings (P < 0.05) for BHVI/MI were identified and their sensitivity and specificity values determined, as follows: bowel wall thickening (39.7%, 96.2%), mesentery thickening (46.6%, 88.5%), mesenteric fat infiltration (12.3%, 98.7%), peritoneal fat infiltration (31.5%, 87.1%), parietal peritoneum thickening (30.1%, 85.9%), and intra- or retro-peritoneal air (34.2%, 96.2%). Unenhanced CT scan was useful as an initial assessment tool for BHVI/MI after blunt abdominal trauma. Six key features on CT were correlated with BHVI/MI.

  11. Whole abdominal wall segmentation using augmented active shape models (AASM) with multi-atlas label fusion and level set

    NASA Astrophysics Data System (ADS)

    Xu, Zhoubing; Baucom, Rebeccah B.; Abramson, Richard G.; Poulose, Benjamin K.; Landman, Bennett A.

    2016-03-01

    The abdominal wall is an important structure differentiating subcutaneous and visceral compartments and intimately involved with maintaining abdominal structure. Segmentation of the whole abdominal wall on routinely acquired computed tomography (CT) scans remains challenging due to variations and complexities of the wall and surrounding tissues. In this study, we propose a slice-wise augmented active shape model (AASM) approach to robustly segment both the outer and inner surfaces of the abdominal wall. Multi-atlas label fusion (MALF) and level set (LS) techniques are integrated into the traditional ASM framework. The AASM approach globally optimizes the landmark updates in the presence of complicated underlying local anatomical contexts. The proposed approach was validated on 184 axial slices of 20 CT scans. The Hausdorff distance against the manual segmentation was significantly reduced using proposed approach compared to that using ASM, MALF, and LS individually. Our segmentation of the whole abdominal wall enables the subcutaneous and visceral fat measurement, with high correlation to the measurement derived from manual segmentation. This study presents the first generic algorithm that combines ASM, MALF, and LS, and demonstrates practical application for automatically capturing visceral and subcutaneous fat volumes.

  12. Low-dose CT in clinical diagnostics.

    PubMed

    Fuentes-Orrego, Jorge M; Sahani, Dushyant V

    2013-09-01

    Computed tomography (CT) has become key for patient management due to its outstanding capabilities for detecting disease processes and assessing treatment response, which has led to expansion in CT imaging for diagnostic and image-guided therapeutic interventions. Despite these benefits, the growing use of CT has raised concerns as radiation risks associated with radiation exposure. The purpose of this article is to familiarize the reader with fundamental concepts of dose metrics for assessing radiation exposure and weighting radiation-associated risks. The article also discusses general approaches for reducing radiation dose while preserving diagnostic quality. The authors provide additional insight for undertaking protocol optimization, customizing scanning techniques based on the patients' clinical scenario and demographics. Supplemental strategies are postulated using more advanced post-processing techniques for achieving further dose improvements. The technologic offerings of CT are integral to modern medicine and its role will continue to evolve. Although, the estimated risks from low levels of radiation of a single CT exam are uncertain, it is prudent to minimize the dose from CT by applying common sense solutions and using other simple strategies as well as exploiting technologic innovations. These efforts will enable us to take advantage of all the clinical benefits of CT while minimizing the likelihood of harm to patients.

  13. Medical Student Dissection of Cadavers Improves Performance on Practical Exams but not on the NBME Anatomy Subject Exam.

    PubMed

    Sargent Jones, Leslie; Paulman, Lance E; Thadani, Raj; Terracio, Louis

    2001-12-01

    We have examined whether cadaver dissection by first year medical students (MIs) affected their performance in two test measures: the NBME Gross Anatomy and Embryology Subject Exam (dissection-relevant questions only), and practical exams given at the end of each major section within the course. The dissections for the entire course were divided into 18 regional dissection units and each student was assigned to dissect one third of the regional units; the other two-thirds of the material was learned from the partner-prosected cadavers. Performance for each student on the exams was then assessed as a function of the regions those students actually dissected. While the results indicated a small performance advantage for MIs answering questions on material they had dissected on the NBME Subject Exam questions relevant to dissection (78-88% of total exam), the results were not statistically significant. However, a similar, small performance advantage on the course practical exams was highly significant.

  14. Abdominal Hernias, Giant Colon Diverticulum, GIST, Intestinal Pneumatosis, Colon Ischemia, Cold Intussusception, Gallstone Ileus, and Foreign Bodies: Our Experience and Literature Review of Incidental Gastrointestinal MDCT Findings

    PubMed Central

    Gatta, G.; Rella, R.; Donatello, D.; Falco, G.; Grassi, R.

    2017-01-01

    Incidental gastrointestinal findings are commonly detected on MDCT exams performed for various medical indications. This review describes the radiological MDCT spectrum of appearances already present in the past literature and in today's experience of several gastrointestinal acute conditions such as abdominal hernia, giant colon diverticulum, GIST, intestinal pneumatosis, colon ischemia, cold intussusception, gallstone ileus, and foreign bodies which can require medical and surgical intervention or clinical follow-up. The clinical presentation of this illness is frequently nonspecific: abdominal pain, distension, nausea, fever, rectal bleeding, vomiting, constipation, or a palpable mass, depending on the disease. A proper differential diagnosis is essential in the assessment of treatment and in this case MDCT exam plays a central rule. We wish that this article will familiarize the radiologist in the diagnosis of this kind of incidental MDCT findings for better orientation of the therapy. PMID:28638830

  15. Abdominal Hernias, Giant Colon Diverticulum, GIST, Intestinal Pneumatosis, Colon Ischemia, Cold Intussusception, Gallstone Ileus, and Foreign Bodies: Our Experience and Literature Review of Incidental Gastrointestinal MDCT Findings.

    PubMed

    Di Grezia, G; Gatta, G; Rella, R; Donatello, D; Falco, G; Grassi, R; Grassi, R

    2017-01-01

    Incidental gastrointestinal findings are commonly detected on MDCT exams performed for various medical indications. This review describes the radiological MDCT spectrum of appearances already present in the past literature and in today's experience of several gastrointestinal acute conditions such as abdominal hernia, giant colon diverticulum, GIST, intestinal pneumatosis, colon ischemia, cold intussusception, gallstone ileus, and foreign bodies which can require medical and surgical intervention or clinical follow-up. The clinical presentation of this illness is frequently nonspecific: abdominal pain, distension, nausea, fever, rectal bleeding, vomiting, constipation, or a palpable mass, depending on the disease. A proper differential diagnosis is essential in the assessment of treatment and in this case MDCT exam plays a central rule. We wish that this article will familiarize the radiologist in the diagnosis of this kind of incidental MDCT findings for better orientation of the therapy.

  16. Correlation between model observers in uniform background and human observers in patient liver background for a low-contrast detection task in CT

    NASA Astrophysics Data System (ADS)

    Gong, Hao; Yu, Lifeng; Leng, Shuai; Dilger, Samantha; Zhou, Wei; Ren, Liqiang; McCollough, Cynthia H.

    2018-03-01

    Channelized Hotelling observer (CHO) has demonstrated strong correlation with human observer (HO) in both single-slice viewing mode and multi-slice viewing mode in low-contrast detection tasks with uniform background. However, it remains unknown if the simplest single-slice CHO in uniform background can be used to predict human observer performance in more realistic tasks that involve patient anatomical background and multi-slice viewing mode. In this study, we aim to investigate the correlation between CHO in a uniform water background and human observer performance at a multi-slice viewing mode on patient liver background for a low-contrast lesion detection task. The human observer study was performed on CT images from 7 abdominal CT exams. A noise insertion tool was employed to synthesize CT scans at two additional dose levels. A validated lesion insertion tool was used to numerically insert metastatic liver lesions of various sizes and contrasts into both phantom and patient images. We selected 12 conditions out of 72 possible experimental conditions to evaluate the correlation at various radiation doses, lesion sizes, lesion contrasts and reconstruction algorithms. CHO with both single and multi-slice viewing modes were strongly correlated with HO. The corresponding Pearson's correlation coefficient was 0.982 (with 95% confidence interval (CI) [0.936, 0.995]) and 0.989 (with 95% CI of [0.960, 0.997]) in multi-slice and single-slice viewing modes, respectively. Therefore, this study demonstrated the potential to use the simplest single-slice CHO to assess image quality for more realistic clinically relevant CT detection tasks.

  17. Impact of the clinical ultrasound elective course on retention of anatomical knowledge by second-year medical students in preparation for board exams.

    PubMed

    Kondrashov, Peter; Johnson, Jane C; Boehm, Karl; Rice, Daris; Kondrashova, Tatyana

    2015-03-01

    Ultrasound has been integrated into a gross anatomy course taught during the first year at an osteopathic medical school. A clinical ultrasound elective course was developed to continue ultrasound training during the second year of medical school. The purpose of this study was to evaluate the impact of this elective course on the understanding of normal anatomy by second-year students. An anatomy exam was administered to students enrolled in the clinical ultrasound elective course before the start of the course and after its conclusion. Wilcoxon signed ranks tests were used to determine whether exam scores changed from the pre-test to the post-test. Scores from two classes of second-year students were analyzed. Students who took the elective course showed significant improvement in the overall anatomy exam score between the pre-test and post-test (P < 0.001). Scores for exam questions pertaining to the heart, abdomen, upper extremity, and lower extremity also significantly improved from the pretest to post-test (P < 0.001), but scores for the neck and eye showed no significant improvement. The clinical ultrasound elective course offered during the second year of medical school provided students with an important review of key anatomical concepts while preparing them for board exams. Our results suggested that more emphasis should be placed on head and neck ultrasound to improve student performance in those areas. Musculoskeletal, abdominal, and heart ultrasound labs were more successful for retaining relevant anatomical information. © 2014 Wiley Periodicals, Inc.

  18. Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flores-M, E.; Gamboa de Buen, I.; Buenfil, A. E.

    Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used wasmore » a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.« less

  19. Eye Exam

    MedlinePlus

    ... may use a variety of instruments, shine bright lights directly at your eyes and request that you ... exam is complete, as daylight or other bright lights may be uncomfortable or cause blurred vision. Also, ...

  20. Methamphetamine consumption and life-threatening abdominal complications: A case report.

    PubMed

    Zou, Xiaojing; Huang, Haiyan; Yang, Le; Liu, Hong; Li, Yongfeng; Xia, Qin; Yuan, Shiying; Yao, Shanglong

    2018-05-01

    Methamphetamine (METH) abuse is increasing rapidly all over the world and becoming a significant public health concern in China. However, abdominal complications secondary to METH abuse are usually overlooked. We describe an unusual case of gangrenous cholecystitis and small intestinal ischemia due to METH abuse. In this report, a 44-year-old male patient with abdominal pain and hematochezia has a history of crystal meth abuse. The patient was diagnosed as septic shock, paralytic ileus, gangrenous cholecystitis, and small intestinal ischemia due to METH abuse based on computed tomography (CT) scan, endoscopy examination, laparotomy, and pathology. Antishock treatment, broad-spectrum antibiotics, and exploratory laparotomy were given. The patient survived. Six months later, he tolerated oral intake and stopped using crystal METH. Visceral ischemia should be considered if an adult patient with a history of METH abuse is accompanied by abdominal pain and hematochezia.

  1. Clinic exam room design: present and future.

    PubMed

    Freihoefer, Kara; Nyberg, Gary; Vickery, Christine

    2013-01-01

    This article aims to deconstruct various design qualities and strategies of clinic exam rooms, and discuss how they influence users' interaction and behavior in the space. Relevant literature supports the advantages and disadvantages of different design strategies. Annotated exam room prototypes illustrate the design qualities and strategies discussed. Advancements in technology and medicine, along with new legislative policies, are influencing the way care providers deliver care and ultimately clinic exam room designs. The patient-centered medical home model has encouraged primary care providers to make patients more active leaders of their health plan which will influence the overall functionality and configuration of clinic exam rooms. Specific design qualities discussed include overall size, location of doors and privacy curtains, positioning of exam tables, influence of technology in the consultation area, types of seating, and placement of sink and hand sanitizing dispensers. In addition, future trends of exam room prototypes are presented. There is a general lack of published evidence to support design professionals' design solutions for outpatient exam rooms. Future research should investigate such topics as the location of exam tables and privacy curtains as they relate to patient privacy; typical size and location of consultation table as it relates to patient connection and communication; and placement of sinks and sanitization dispensers as they relate to frequency and patterns of usage. Literature review, outpatient, technology, visual privacy.

  2. High-Grade Serous Ovarian Cancer: Use of Machine Learning to Predict Abdominopelvic Recurrence on CT on the Basis of Serial Cancer Antigen 125 Levels.

    PubMed

    Shinagare, Atul B; Balthazar, Patricia; Ip, Ivan K; Lacson, Ronilda; Liu, Joyce; Ramaiya, Nikhil; Khorasani, Ramin

    2018-05-19

    The aim of this study was to use machine learning to predict abdominal recurrence on CT on the basis of serial cancer antigen 125 (CA125) levels in patients with advanced high-grade serous ovarian cancer on surveillance. This institutional review board-approved, HIPAA-compliant, retrospective, hypothesis-generating study included all 57 patients (mean age, 61 ± 11.2 years) with advanced high-grade serous ovarian cancer who underwent cytoreductive surgery from January to December 2012, followed by surveillance abdominopelvic CT and corresponding CA125 levels. A blinded radiologist reviewed abdominopelvic CT studies until recurrence was noted. Four measures of CA125 were assessed: actual CA125 levels at the time of CT, absolute change since prior CT, relative change since prior CT, and rate of change since prior CT. Using machine learning, support vector machine models were optimized and evaluated using 10-fold cross-validation to determine the CA125 measure most predictive of abdominal recurrence. The association of the most accurate CA125 measure was further analyzed using Cox proportional-hazards model along with age, tumor size, stage, and degree of cytoreduction. Rate of change in CA125 was most predictive of abdominal recurrence in a linear kernel support vector machine model and was significantly higher preceding CT studies showing abdominal recurrence (median 13.2 versus 0.6 units/month; P = .007). On multivariate analysis, a higher rate of CA125 increase was significantly associated with recurrence (hazard ratio, 1.02 per 10 units change; 95% confidence interval, 1.0006-1.04; P = .04). A higher rate of CA125 increase is associated with abdominal recurrence. The rate of increase of CA125 may help in the selection of patients who are most likely to benefit from abdominopelvic CT in surveillance of ovarian cancer. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. The Detection of Focal Liver Lesions Using Abdominal CT: A Comparison of Image Quality Between Adaptive Statistical Iterative Reconstruction V and Adaptive Statistical Iterative Reconstruction.

    PubMed

    Lee, Sangyun; Kwon, Heejin; Cho, Jihan

    2016-12-01

    To investigate image quality characteristics of abdominal computed tomography (CT) scans reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) vs currently using applied adaptive statistical iterative reconstruction (ASIR). This institutional review board-approved study included 35 consecutive patients who underwent CT of the abdomen. Among these 35 patients, 27 with focal liver lesions underwent abdomen CT with a 128-slice multidetector unit using the following parameters: fixed noise index of 30, 1.25 mm slice thickness, 120 kVp, and a gantry rotation time of 0.5 seconds. CT images were analyzed depending on the method of reconstruction: ASIR (30%, 50%, and 70%) vs ASIR-V (30%, 50%, and 70%). Three radiologists independently assessed randomized images in a blinded manner. Imaging sets were compared to focal lesion detection numbers, overall image quality, and objective noise with a paired sample t test. Interobserver agreement was assessed with the intraclass correlation coefficient. The detection of small focal liver lesions (<10 mm) was significantly higher when ASIR-V was used when compared to ASIR (P <0.001). Subjective image noise, artifact, and objective image noise in liver were generally significantly better for ASIR-V compared to ASIR, especially in 50% ASIR-V. Image sharpness and diagnostic acceptability were significantly worse in 70% ASIR-V compared to various levels of ASIR. Images analyzed using 50% ASIR-V were significantly better than three different series of ASIR or other ASIR-V conditions at providing diagnostically acceptable CT scans without compromising image quality and in the detection of focal liver lesions. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  4. SU-F-207-14: Low Contrast Detectability (LCD) at Different Diagnostic Reference Levels for Adult Abdominal CT Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahmood, U; Erdi, Y

    2015-06-15

    Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrixmore » was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.« less

  5. Emergency medicine physicians' and pediatricians' use of computed tomography in the evaluation of pediatric patients with abdominal pain without trauma in a community hospital.

    PubMed

    Grim, Paul Francis

    2014-05-01

    There is a paucity of data regarding emergency department (ED) provider type and computed tomography (CT) scan use in the evaluation of pediatric patients with abdominal pain without trauma. The purpose of this retrospective single community hospital study was to determine if there was a difference in CT use between emergency medicine physicians (EMPs) and pediatricians (PEDs) in all patients younger than 18 years with abdominal pain without trauma who presented to the ED during the study period. The study included 165 patients. EMPs saw 83 patients and used CT in 31 compared with PEDs who saw 82 patients and used CT in 12 (P = .002). EMPs used CT significantly more frequently than PEDs in the designated sample. Economic pressures may cause changes in ED provider type in community and rural hospitals and this study shows that ED provider type may affect medical decision making, including CT use.

  6. Standard Anatomic Terminologies: Comparison for Use in a Health Information Exchange–Based Prior Computed Tomography (CT) Alerting System

    PubMed Central

    Lowry, Tina; Vreeman, Daniel J; Loo, George T; Delman, Bradley N; Thum, Frederick L; Slovis, Benjamin H; Shapiro, Jason S

    2017-01-01

    Background A health information exchange (HIE)–based prior computed tomography (CT) alerting system may reduce avoidable CT imaging by notifying ordering clinicians of prior relevant studies when a study is ordered. For maximal effectiveness, a system would alert not only for prior same CTs (exams mapped to the same code from an exam name terminology) but also for similar CTs (exams mapped to different exam name terminology codes but in the same anatomic region) and anatomically proximate CTs (exams in adjacent anatomic regions). Notification of previous same studies across an HIE requires mapping of local site CT codes to a standard terminology for exam names (such as Logical Observation Identifiers Names and Codes [LOINC]) to show that two studies with different local codes and descriptions are equivalent. Notifying of prior similar or proximate CTs requires an additional mapping of exam codes to anatomic regions, ideally coded by an anatomic terminology. Several anatomic terminologies exist, but no prior studies have evaluated how well they would support an alerting use case. Objective The aim of this study was to evaluate the fitness of five existing standard anatomic terminologies to support similar or proximate alerts of an HIE-based prior CT alerting system. Methods We compared five standard anatomic terminologies (Foundational Model of Anatomy, Systematized Nomenclature of Medicine Clinical Terms, RadLex, LOINC, and LOINC/Radiological Society of North America [RSNA] Radiology Playbook) to an anatomic framework created specifically for our use case (Simple ANatomic Ontology for Proximity or Similarity [SANOPS]), to determine whether the existing terminologies could support our use case without modification. On the basis of an assessment of optimal terminology features for our purpose, we developed an ordinal anatomic terminology utility classification. We mapped samples of 100 random and the 100 most frequent LOINC CT codes to anatomic regions in each

  7. Helping Struggling Students: The Impact of Three Instructional Interventions on College Students' Exam Scores and Exam-Skipping Behavior

    ERIC Educational Resources Information Center

    Thomas, Nichole Gibbs; Thomas, Antonio Lamar

    2018-01-01

    Whether instructional-communication feedback sent to struggling students and succeeding students following course exams would significantly increase their exam scores and significantly decrease their exam-skipping behavior relative to students in the control group was investigated. An experimenter-blind study utilizing feedback and the…

  8. Automatic abdominal multi-organ segmentation using deep convolutional neural network and time-implicit level sets.

    PubMed

    Hu, Peijun; Wu, Fa; Peng, Jialin; Bao, Yuanyuan; Chen, Feng; Kong, Dexing

    2017-03-01

    Multi-organ segmentation from CT images is an essential step for computer-aided diagnosis and surgery planning. However, manual delineation of the organs by radiologists is tedious, time-consuming and poorly reproducible. Therefore, we propose a fully automatic method for the segmentation of multiple organs from three-dimensional abdominal CT images. The proposed method employs deep fully convolutional neural networks (CNNs) for organ detection and segmentation, which is further refined by a time-implicit multi-phase evolution method. Firstly, a 3D CNN is trained to automatically localize and delineate the organs of interest with a probability prediction map. The learned probability map provides both subject-specific spatial priors and initialization for subsequent fine segmentation. Then, for the refinement of the multi-organ segmentation, image intensity models, probability priors as well as a disjoint region constraint are incorporated into an unified energy functional. Finally, a novel time-implicit multi-phase level-set algorithm is utilized to efficiently optimize the proposed energy functional model. Our method has been evaluated on 140 abdominal CT scans for the segmentation of four organs (liver, spleen and both kidneys). With respect to the ground truth, average Dice overlap ratios for the liver, spleen and both kidneys are 96.0, 94.2 and 95.4%, respectively, and average symmetric surface distance is less than 1.3 mm for all the segmented organs. The computation time for a CT volume is 125 s in average. The achieved accuracy compares well to state-of-the-art methods with much higher efficiency. A fully automatic method for multi-organ segmentation from abdominal CT images was developed and evaluated. The results demonstrated its potential in clinical usage with high effectiveness, robustness and efficiency.

  9. Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms.

    PubMed

    Shimonobo, Toshiaki; Funama, Yoshinori; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, Kazuo

    2016-01-01

    We used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT. Using a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors. The mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p < 0.01). Compared to adults, the surface and center dose for pediatric patients is almost the same despite a decrease in the tube voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. COMPARISON OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION (ASIR™) AND MODEL-BASED ITERATIVE RECONSTRUCTION (VEO™) FOR PAEDIATRIC ABDOMINAL CT EXAMINATIONS: AN OBSERVER PERFORMANCE STUDY OF DIAGNOSTIC IMAGE QUALITY.

    PubMed

    Hultenmo, Maria; Caisander, Håkan; Mack, Karsten; Thilander-Klang, Anne

    2016-06-01

    The diagnostic image quality of 75 paediatric abdominal computed tomography (CT) examinations reconstructed with two different iterative reconstruction (IR) algorithms-adaptive statistical IR (ASiR™) and model-based IR (Veo™)-was compared. Axial and coronal images were reconstructed with 70 % ASiR with the Soft™ convolution kernel and with the Veo algorithm. The thickness of the reconstructed images was 2.5 or 5 mm depending on the scanning protocol used. Four radiologists graded the delineation of six abdominal structures and the diagnostic usefulness of the image quality. The Veo reconstruction significantly improved the visibility of most of the structures compared with ASiR in all subgroups of images. For coronal images, the Veo reconstruction resulted in significantly improved ratings of the diagnostic use of the image quality compared with the ASiR reconstruction. This was not seen for the axial images. The greatest improvement using Veo reconstruction was observed for the 2.5 mm coronal slices. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Prospective Evaluation of Prior Image Constrained Compressed Sensing (PICCS) Algorithm in Abdominal CT: A comparison of reduced dose with standard dose imaging

    PubMed Central

    Lubner, Meghan G.; Pickhardt, Perry J.; Kim, David H.; Tang, Jie; Munoz del Rio, Alejandro; Chen, Guang-Hong

    2014-01-01

    Purpose To prospectively study CT dose reduction using the “prior image constrained compressed sensing” (PICCS) reconstruction technique. Methods Immediately following routine standard dose (SD) abdominal MDCT, 50 patients (mean age, 57.7 years; mean BMI, 28.8) underwent a second reduced-dose (RD) scan (targeted dose reduction, 70-90%). DLP, CTDIvol and SSDE were compared. Several reconstruction algorithms (FBP, ASIR, and PICCS) were applied to the RD series. SD images with FBP served as reference standard. Two blinded readers evaluated each series for subjective image quality and focal lesion detection. Results Mean DLP, CTDIvol, and SSDE for RD series was 140.3 mGy*cm (median 79.4), 3.7 mGy (median 1.8), and 4.2 mGy (median 2.3) compared with 493.7 mGy*cm (median 345.8), 12.9 mGy (median 7.9 mGy) and 14.6 mGy (median 10.1) for SD series, respectively. Mean effective patient diameter was 30.1 cm (median 30), which translates to a mean SSDE reduction of 72% (p<0.001). RD-PICCS image quality score was 2.8±0.5, improved over the RD-FBP (1.7±0.7) and RD-ASIR(1.9±0.8)(p<0.001), but lower than SD (3.5±0.5)(p<0.001). Readers detected 81% (184/228) of focal lesions on RD-PICCS series, versus 67% (153/228) and 65% (149/228) for RD-FBP and RD-ASIR, respectively. Mean image noise was significantly reduced on RD-PICCS series (13.9 HU) compared with RD-FBP (57.2) and RD-ASIR (44.1) (p<0.001). Conclusion PICCS allows for marked dose reduction at abdominal CT with improved image quality and diagnostic performance over reduced-dose FBP and ASIR. Further study is needed to determine indication-specific dose reduction levels that preserve acceptable diagnostic accuracy relative to higher-dose protocols. PMID:24943136

  12. Cognitive Difficulty and Format of Exams Predicts Gender and Socioeconomic Gaps in Exam Performance of Students in Introductory Biology Courses

    PubMed Central

    Wright, Christian D.; Eddy, Sarah L.; Wenderoth, Mary Pat; Abshire, Elizabeth; Blankenbiller, Margaret; Brownell, Sara E.

    2016-01-01

    Recent reform efforts in undergraduate biology have recommended transforming course exams to test at more cognitively challenging levels, which may mean including more cognitively challenging and more constructed-response questions on assessments. However, changing the characteristics of exams could result in bias against historically underserved groups. In this study, we examined whether and to what extent the characteristics of instructor-generated tests impact the exam performance of male and female and middle/high- and low-socioeconomic status (SES) students enrolled in introductory biology courses. We collected exam scores for 4810 students from 87 unique exams taken across 3 yr of the introductory biology series at a large research university. We determined the median Bloom’s level and the percentage of constructed-response questions for each exam. Despite controlling for prior academic ability in our models, we found that males and middle/high-SES students were disproportionately favored as the Bloom’s level of exams increased. Additionally, middle/high-SES students were favored as the proportion of constructed-response questions on exams increased. Given that we controlled for prior academic ability, our findings do not likely reflect differences in academic ability level. We discuss possible explanations for our findings and how they might impact how we assess our students. PMID:27252299

  13. Colitis detection on abdominal CT scans by rich feature hierarchies

    NASA Astrophysics Data System (ADS)

    Liu, Jiamin; Lay, Nathan; Wei, Zhuoshi; Lu, Le; Kim, Lauren; Turkbey, Evrim; Summers, Ronald M.

    2016-03-01

    Colitis is inflammation of the colon due to neutropenia, inflammatory bowel disease (such as Crohn disease), infection and immune compromise. Colitis is often associated with thickening of the colon wall. The wall of a colon afflicted with colitis is much thicker than normal. For example, the mean wall thickness in Crohn disease is 11-13 mm compared to the wall of the normal colon that should measure less than 3 mm. Colitis can be debilitating or life threatening, and early detection is essential to initiate proper treatment. In this work, we apply high-capacity convolutional neural networks (CNNs) to bottom-up region proposals to detect potential colitis on CT scans. Our method first generates around 3000 category-independent region proposals for each slice of the input CT scan using selective search. Then, a fixed-length feature vector is extracted from each region proposal using a CNN. Finally, each region proposal is classified and assigned a confidence score with linear SVMs. We applied the detection method to 260 images from 26 CT scans of patients with colitis for evaluation. The detection system can achieve 0.85 sensitivity at 1 false positive per image.

  14. Diagnostic accuracy of non-contrast abdominal CT scans performed as follow-up for patients with an established cancer diagnosis: a retrospective study.

    PubMed

    Semaan, Hassan; Bazerbashi, Mohamad F; Siesel, Geoffrey; Aldinger, Paul; Obri, Tawfik

    2018-03-01

    To determine the accuracy and non-detection rate of cancer related findings (CRFs) on follow-up non-contrast-enhanced CT (NECT) versus contrast-enhanced CT (CECT) images of the abdomen in patients with a known cancer diagnosis. A retrospective review of 352 consecutive CTs of the abdomen performed with and without IV contrast between March 2010 and October 2014 for follow-up of cancer was included. Two radiologists independently assessed the NECT portions of the studies. The reader was provided the primary cancer diagnosis and access to the most recent prior NECT study. The accuracy and non-detection rates were determined by comparing our results to the archived reports as a gold standard. A total of 383 CRFs were found in the archived reports of the 352 abdominal CTs. The average non-detection rate for the NECTs compared to the CECTs was 3.0% (11.5/383) with an accuracy of 97.0% (371.5/383) in identifying CRFs. The most common findings missed were vascular thrombosis with a non-detection rate of 100%. The accuracy for non-vascular CRFs was 99.1%. Follow-up NECT abdomen studies are highly accurate in the detection of CRFs in patients with an established cancer diagnosis, except in cases where vascular involvement is suspected.

  15. Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial.

    PubMed

    Rouchy, R C; Moreau-Gaudry, A; Chipon, E; Aubry, S; Pazart, L; Lapuyade, B; Durand, M; Hajjam, M; Pottier, S; Renard, B; Logier, R; Orry, X; Cherifi, A; Quehen, E; Kervio, G; Favelle, O; Patat, F; De Kerviler, E; Hughes, C; Medici, M; Ghelfi, J; Mounier, A; Bricault, I

    2017-07-06

    Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator's instruments, meaning the position and progression of the instruments are visualised in real time on the patient's images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region. This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and

  16. Optimal Weighting for Exam Composition

    ERIC Educational Resources Information Center

    Ganzfried, Sam; Yusuf, Farzana

    2018-01-01

    A problem faced by many instructors is that of designing exams that accurately assess the abilities of the students. Typically, these exams are prepared several days in advance, and generic question scores are used based on rough approximation of the question difficulty and length. For example, for a recent class taught by the author, there were…

  17. Breast Exam

    MedlinePlus

    ... can cause changes in your breasts, including breast cancer. A breast self-exam for breast awareness isn't a reliable way to screen for ... instructions and technique with your doctor. The American Cancer Society recommends ... have their techniques periodically evaluated by their doctors. ...

  18. Inter-radiologist agreement for CT scoring of pediatric splenic injuries and effect on an established clinical practice guideline.

    PubMed

    Leschied, Jessica R; Mazza, Michael B; Davenport, Matthew; Chong, Suzanne T; Smith, Ethan A; Hoff, Carrie N; Ladino-Torres, Maria F; Khalatbari, Shokoufeh; Ehrlich, Peter F; Dillman, Jonathan R

    2016-02-01

    The American Pediatric Surgical Association (APSA) advocates for the use of a clinical practice guideline to direct management of hemodynamically stable pediatric spleen injuries. The clinical practice guideline is based on the CT score of the spleen injury according to the American Association for the Surgery of Trauma (AAST) CT scoring system. To determine the potential effect of radiologist agreement for CT scoring of pediatric spleen injuries on an established APSA clinical practice guideline. We retrospectively analyzed blunt splenic injuries occurring in children from January 2007 to January 2012 at a single level 1 trauma center (n = 90). Abdominal CT exams performed at clinical presentation were reviewed by four radiologists who documented the following: (1) splenic injury grade (AAST system), (2) arterial extravasation and (3) pseudoaneurysm. Inter-rater agreement for AAST injury grade was assessed using the multi-rater Fleiss kappa and Kendall coefficient of concordance. Inter-rater agreement was assessed using weighted (AAST injury grade) or prevalence-adjusted bias-adjusted (binary measures) kappa statistics; 95% confidence intervals were calculated. We evaluated the hypothetical effect of radiologist disagreement on an established APSA clinical practice guideline. Inter-rater agreement was good for absolute AAST injury grade (kappa: 0.64 [0.59–0.69]) and excellent for relative AAST injury grade (Kendall w: 0.90). All radiologists agreed on the AAST grade in 52% of cases. Based on an established clinical practice guideline, radiologist disagreement could have changed the decision for intensive care management in 11% (10/90) of children, changed the length of hospital stay in 44% (40/90), and changed the time to return to normal activity in 44% (40/90). Radiologist agreement when assigning splenic AAST injury grades is less than perfect, and disagreements have the potential to change management in a substantial number of pediatric patients.

  19. [Combined use of wide-detector and adaptive statistical iterative reconstruction-V technique in abdominal CT with low radiation dose].

    PubMed

    Wang, H X; Lü, P J; Yue, S W; Chang, L Y; Li, Y; Zhao, H P; Li, W R; Gao, J B

    2017-12-05

    Objective: To investigate the image quality and radiation dose with wide-detector(80 mm) and adaptive statistical iterative reconstruction-V (ASIR-V) technique at abdominal contrast enhanced CT scan. Methods: In the first phantom experiment part, the percentage of ASIR-V for half dose of combined wide detector with ASIR-V technique as compared with standard-detector (40 mm) technique was determined. The human experiment was performed based on the phantom study, 160 patients underwent contrast-enhanced abdominal CT scan were prospectively collected and divided into the control group ( n =40) with image reconstruction using 40% ASIR (group A) and the study group ( n =120) with random number table. According to pre-ASIR-V percentage, the study group was assigned into three groups[40 cases in each group, group B: 0 pre-ASIR-V scan with image reconstruction of 0-100% post-ASIR-V (interval 10%, subgroups B0-B10); group C: 20% pre-ASIR-V with 20%, 40% and 60% post-ASIR-V (subgroups C1-C3); group D: 40%pre-ASIR-V with 40% and 60% post-ASIR-V (subgroups D1-D2)]. Image noise, CT attenuation values and CNR of the liver, pancreas, aorta and portal vein were compared by using two sample t test and One-way ANOVA. Qualitative visual parameters (overall image quality as graded on a 5-point scale) was compared by Mann-Whitney U test and Kruskal-Wallis H test. Results: The phantom experiment showed that the percentage of pre-ASIR-V for half dose was 40%. With the 40% pre-ASIR-V, radiation dose in the study group was reduced by 35.5% as compared with the control group. Image noise in the subgroups of B2-B10, C2-C3 and D1-D2 were lower ( t =-14.681--3.046, all P <0.05) while CNR in the subgroups of B4-B10, C2-3 and D1-D2 were higher( t =2.048-9.248, all P <0.05)than those in group A, except the CNR of liver in the arterial phase (AP) in C2, D1 and D2 and the CNR of pancreas in AP in D1 ( t =0.574-1.327, all P >0.05). The subjective image quality scores increased gradually in the range

  20. Deep feature classification of angiomyolipoma without visible fat and renal cell carcinoma in abdominal contrast-enhanced CT images with texture image patches and hand-crafted feature concatenation.

    PubMed

    Lee, Hansang; Hong, Helen; Kim, Junmo; Jung, Dae Chul

    2018-04-01

    To develop an automatic deep feature classification (DFC) method for distinguishing benign angiomyolipoma without visible fat (AMLwvf) from malignant clear cell renal cell carcinoma (ccRCC) from abdominal contrast-enhanced computer tomography (CE CT) images. A dataset including 80 abdominal CT images of 39 AMLwvf and 41 ccRCC patients was used. We proposed a DFC method for differentiating the small renal masses (SRM) into AMLwvf and ccRCC using the combination of hand-crafted and deep features, and machine learning classifiers. First, 71-dimensional hand-crafted features (HCF) of texture and shape were extracted from the SRM contours. Second, 1000-4000-dimensional deep features (DF) were extracted from the ImageNet pretrained deep learning model with the SRM image patches. In DF extraction, we proposed the texture image patches (TIP) to emphasize the texture information inside the mass in DFs and reduce the mass size variability. Finally, the two features were concatenated and the random forest (RF) classifier was trained on these concatenated features to classify the types of SRMs. The proposed method was tested on our dataset using leave-one-out cross-validation and evaluated using accuracy, sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and area under receiver operating characteristics curve (AUC). In experiments, the combinations of four deep learning models, AlexNet, VGGNet, GoogleNet, and ResNet, and four input image patches, including original, masked, mass-size, and texture image patches, were compared and analyzed. In qualitative evaluation, we observed the change in feature distributions between the proposed and comparative methods using tSNE method. In quantitative evaluation, we evaluated and compared the classification results, and observed that (a) the proposed HCF + DF outperformed HCF-only and DF-only, (b) AlexNet showed generally the best performances among the CNN models, and (c) the proposed TIPs

  1. Utility of CT in the diagnosis and management of small-bowel obstruction in children.

    PubMed

    Wang, Qiuyan; Chavhan, Govind B; Babyn, Paul S; Tomlinson, George; Langer, Jacob C

    2012-12-01

    CT is often used in the diagnosis and management of small-bowel obstruction in children. To determine sensitivity of CT in delineating presence, site and cause of small-bowel obstruction in children. We retrospectively reviewed the CT scans of 47 children with surgically proven small-bowel obstruction. We noted any findings of obstruction and the site and cause of obstruction. Presence, absence or equivocal findings of bowel obstruction on abdominal radiographs performed prior to CT were also noted. We reviewed patient charts for clinical details and surgical findings, including bowel resection. Statistical analysis was performed using Fisher exact test to determine which CT findings might predict bowel resection. CT correctly diagnosed small-bowel obstruction in 43/47 (91.5%) cases. CT correctly indicated site of obstruction in 37/47 (78.7%) cases and cause of obstruction in 32/47 (68.1%) cases. Small-bowel feces sign was significantly associated with bowel resection at surgery (P = 0.0091). No other CT finding was predictive of bowel resection. Out of 41 children who had abdominal radiographs before CT, 29 (70.7%) showed unequivocal obstruction, six (14.6%) showed equivocal findings and six (14.6%) were unremarkable. CT is highly sensitive in diagnosing small-bowel obstruction in children and is helpful in determining the presence of small-bowel obstruction in many clinically suspected cases with equivocal or normal plain radiographs. CT also helps to determine the site and cause of the obstruction with good sensitivity.

  2. Analysis of urobilinogen and urine bilirubin for intra-abdominal injury in blunt trauma patients.

    PubMed

    Gorchynski, Julie; Dean, Kevin; Anderson, Craig L

    2009-05-01

    To determine the point prevalence of urine bilirubin, urine hemoglobin and urobilinogen in blunt trauma patients, and to evaluate its utility as a screening tool for intra-abdominal injury. Data analysis of 986 consecutive trauma patients of which 698 were adult blunt trauma patients. Five-hundred sixteen subjects had a urinalysis and a CT scan of the abdomen/pelvis or exploratory laparotomy. We reviewed initial urinalysis results from trauma patients in the emergency department (ED) for the presence of urine hemoglobin, uroblinogen and urine bilirubin. Computed tomography (CT) scan results and operative reports were reviewed from the trauma registry for evidence of liver laceration, spleen laceration, bowel or mesenteric injuries. There were 73 injuries and 57/516 patients (11%) with intra-abdominal injury. Urinalysis was positive for urobilinogen in 28/516 (5.4%) patients, urine bilirubin in 15/516 (2.9%) patients and urine hemoglobin in 313/516 (61%) patients. Nineteen/forty-seven (4%) subjects had liver lacerations, 28/56 (5%) splenic lacerations, and 15/5 (3%) bowel or mesenteric injury. Comparing the proportion of patients that had urobilinogen detected in the group with and without intra-abdominal injury, 8/28 (29%) subjects with urobilinogen, 5/15 (33%) subjects with bilirubin and 47/313 (15%) subjects with urine hemoglobin were found to have liver lacerations, spleen lacerations, or bowel/mesenteric injuries. Preexisting liver or biliary conditions were not statistically associated with elevation of urine bilirubin, urine hemoglobin or urobilinogen on initial urinalysis after blunt abdominal trauma. Point prevalence for urobilinogen, urine bilirubin and urine hemoglobin are 5.43% (28/516), 2.91% (15/516) and 60.7% (313/516) respectively. The utility of the initial routine urinalysis in the ED for adult blunt abdominal trauma patients should not be used as a screening tool for the evaluation of intra-abdominal injury.

  3. Enabling image fusion for a CT guided needle placement robot

    NASA Astrophysics Data System (ADS)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.

    2017-03-01

    Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.

  4. Computed tomography has an important role in hollow viscus and mesenteric injuries after blunt abdominal trauma.

    PubMed

    Tan, Ker-Kan; Liu, Jody Zhiyang; Go, Tsung-Shyen; Vijayan, Appasamy; Chiu, Ming-Terk

    2010-05-01

    Computed tomographic (CT) scans have become invaluable in the management of patients with blunt abdominal trauma. No clear consensus exists on its role in hollow viscus injuries (HVI) and mesenteric injuries (MI). The aim of this study was to correlate operative findings of HVI and MI to findings on pre-operative CT. All patients treated for blunt abdominal trauma at Tan Tock Seng Hospital from January 2003 to January 2008 were reviewed. CT scans were only performed if the patients were haemodynamically stable and indicated. All scans were performed with intravenous contrast using a 4-slice CT scanner from 2003 to December 2004 and a 64-slice CT scanner from January 2005 onwards. All cases with documented HVI/MI that underwent both CT scans and exploratory laparotomy were analysed. Thirty-one patients formed the study group, with median age of 40 (range, 22-65) years and a significant male (83.9%) predominance. Vehicular-related incidents accounted for 67.7% of the injuries and the median Injury Severity Score (ISS) was 13 (4-50). The 2 commonest findings on CT scans were extra-luminal gas (35.5%) and free fluid without significant solid organ injuries (93.5%). During exploratory laparotomy, perforation of hollow viscus (51.6%) occurred more frequently than suspected from the initial CT findings of extra-luminal gas. Other notable findings included haemoperitoneum (64.5%), and mesenteric tears (67.7%). None of our patients with HVI and MI had a normal pre-operative CT scan. Our study suggests that patients with surgically confirmed HVI and MI found at laparotomy were very likely to have an abnormal pre-operative CT scan. Unexplained free fluid was a very common finding in blunt HVI/MI and is one major indication to consider exploratory laparotomy. (c) 2009 Elsevier Ltd. All rights reserved.

  5. Overuse of CT and MRI in paediatric emergency departments.

    PubMed

    Ohana, Orly; Soffer, Shelly; Zimlichman, Eyal; Klang, Eyal

    2018-05-01

    The aim of this review is to survey CT and MRI overuse in the paediatric emergency department (ED) population. CT is one of the most important modalities employed in the ED. Not surprisingly, its high accuracy, rapid acquisition and availability have resulted in overuse. An obvious limitation of CT is ionizing radiation; in addition there are economic implications to overuse. Studies from the last two decades have shown increase in paediatric ED CT utilization in the first decade, reaching a plateau forming around 2008, followed by a decrease in the last decade. This decrease occurred in conjunction with campaigns raising awareness to the risks of radiation exposure. Although a trend of decrease in overuse have been observed, great variability has been shown across different facilities, as well as among physicians, with more pronounced overuse in non-teaching and non-children dedicated EDs. The leading types of paediatric ED CTs are head and abdominal scans. Decision rules, such as PECARN for head injury and the Alvarado score for abdominal pain, as well as using alternative imaging modalities, have been shown to reduce CT overuse in these two categories. MRI has the obvious benefit of avoiding radiation exposure, but the disadvantages of higher costs, less availability and less tolerability in younger children. Although anecdotally paediatric ED MRI usage has increased in recent years, only scarce reports have been published. In our opinion, there is need to conduct up-to-date studies covering paediatric CT and MRI overuse trends, usage variability and adherence to clinical protocols.

  6. Dioctophyma renale (Goeze, 1782) in the abdominal cavity of a capuchin monkey (Cebus apella), Brazil.

    PubMed

    Ishizaki, Mirian Naomi; Imbeloni, Aline Amaral; Muniz, José Augusto Pereira Carneiro; Scalercio, Sarah Raphaella Rocha de Azevedo; Benigno, Raimundo Nonato Moraes; Pereira, Washington Luiz Assunção; Cunha Lacreta Junior, Antonio Carlos

    2010-10-29

    This study reports a case of parasitism by Dioctophyma renale (Goeze, 1762) encysted in the abdominal cavity of a capuchin monkey (Cebus apella) coming from the Centro Nacional de Primatas, Brazil. The animal was sent to the Veterinary Clinic sector with an increase in abdominal volume and no occurrence of any other clinical signs. Upon palpation, a movable circular mass with a diameter of approximately 10 cm was found. Urinalysis, complete blood count and serum biochemistry were performed without revealing any alterations. The animal was then submitted to an abdominal ultrasound exam. The cyst was punctured and a surgical removal procedure was performed, revealing a brownish-colored cylindrical structure that was already deteriorated, making it impossible to perform morphological analysis and classification. In the sediment of the liquid found, eggs were encountered that had morphological characteristics compatible with D. renale. The objective of this paper is to report the first case of parasitism by D. renale in C. apella (Linnaeus, 1758). Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Abdominal rectus muscle atrophy and midline shift after colostomy creation.

    PubMed

    Timmermans, Lucas; Deerenberg, Eva B; van Dijk, Sven M; Lamme, Bas; Koning, Anton H; Kleinrensink, Gert-Jan; Jeekel, Johannes; Lange, Johan F

    2014-04-01

    Incisional hernia (IH) can be attributed to multiple factors. The presence of a parastomal hernia has shown to be a risk factor for IH after midline laparotomy. Our hypothesis is that this increased risk of IH may be caused by changes in biomechanical forces, such as midline shift to the contralateral side of the colostomy owing to decreased restraining forces at the site of the colostomy, and left abdominal rectus muscle (ARM) atrophy owing to intercostal nerve damage. Patients were selected if they underwent end-colostomy via open operation between 2004 and 2011. Patients were eligible if computed tomography (CT) had been performed postoperatively. If available, preoperative CTs were collected for case-control analyses. Midline shift was measured using V-scope application in the I-space, a CAVE-like virtual reality system. For the ARM atrophy hypothesis, measurements of ARM were performed at the level of colostomy, and 3 and 8 cm cranial and caudal of the colostomy. Postoperative CT were available for 77 patients; of these patients, 30 also had a preoperative CT. Median follow-up was 19 months. A mean shift to the right side was identified after preoperative and postoperative comparison; from -1.3 ± 4.6 to 2.1 ± 9.3 (P = .043). Furthermore, during rectus muscle measurements, a thinner left ARM was observed below the level of colostomy. Creation of a colostomy alters the abdominal wall. Atrophy of the left ARM was seen caudal to the level of the colostomy, and a midline shift to the right side was evident on CT. These changes may explain the increased rate of IH after colostomy creation. Copyright © 2014 Mosby, Inc. All rights reserved.

  8. The challenging image-guided abdominal mass biopsy: established and emerging techniques 'if you can see it, you can biopsy it'.

    PubMed

    Sainani, Nisha I; Arellano, Ronald S; Shyn, Paul B; Gervais, Debra A; Mueller, Peter R; Silverman, Stuart G

    2013-08-01

    Image-guided percutaneous biopsy of abdominal masses is among the most commonly performed procedures in interventional radiology. While most abdominal masses are readily amenable to percutaneous biopsy, some may be technically challenging for a number of reasons. Low lesion conspicuity, small size, overlying or intervening structures, motion, such as that due to respiration, are some of the factors that can influence the ability and ultimately the success of an abdominal biopsy. Various techniques or technologies, such as choice of imaging modality, use of intravenous contrast and anatomic landmarks, patient positioning, organ displacement or trans-organ approach, angling CT gantry, triangulation method, real-time guidance with CT fluoroscopy or ultrasound, sedation or breath-hold, pre-procedural image fusion, electromagnetic tracking, and others, when used singularly or in combination, can overcome these challenges to facilitate needle placement in abdominal masses that otherwise would be considered not amenable to percutaneous biopsy. Familiarity and awareness of these techniques allows the interventional radiologist to expand the use of percutaneous biopsy in clinical practice, and help choose the most appropriate technique for a particular patient.

  9. Acute gastrointestinal vaso-occlusive ischemia in sickle cell disease: CT imaging features and clinical outcome.

    PubMed

    Gardner, Carly S; Jaffe, Tracy A

    2016-03-01

    The purpose of this study was to determine the incidence, specific imaging features, and outcome of gastrointestinal vaso-occlusive ischemia (GVOI) in sickle cell patients undergoing CT for acute abdominal pain. This HIPAA-compliant, IRB-approved retrospective study evaluated sickle cell patients with an abdominal pain crisis and acute gastrointestinal abnormalities on CT from 1/2006 to 1/2014. CT findings were divided into those compatible and incompatible with bowel ischemia or clinical diagnosis of GVOI. Two abdominal radiologists (1, 13 years' experience) reviewed the CTs for specific imaging features of ischemia. Clinical laboratory values (lactate, WBC) and outcome were recorded. Descriptive statistics and Wilcoxon-Mann-Whitney two-sample rank-sum test were performed. Of 217 CTs, 33 had acute gastrointestinal abnormalities: 75% (25/33) consistent with ischemia and clinical GVOI. Complications of ischemia occurred in 16% (4/25): ileus (50%), perforation (25%), and pneumatosis (25%). In uncomplicated cases, all had bowel wall thickening: segmental 52% (11/21) or diffuse 48% (10/21). The colon was commonly involved (76%, 16/21), particularly the ascending (57%, 12/21). Most abnormalities (52%, 11/21) were in the superior mesenteric artery distribution. Average lactate (4.3 ± 4.0 mmol/L, p = 0.02) and WBC count (20.1 ± 10.4, ×1000 cells/μL, p = 0.01) were significantly higher in GVOI. Overall mortality in patients with GVOI was 17% (3/18). GVOI is an important feature of the acute abdominal crisis in patients with sickle cell disease and can be seen in up to 75% of patients with abnormal bowel findings on CT. The diagnosis should be strongly considered in sickle cell patients with CT findings of diffuse or segmental bowel wall thickening, particularly involving the colon.

  10. Neural network fusion: a novel CT-MR aortic aneurysm image segmentation method

    NASA Astrophysics Data System (ADS)

    Wang, Duo; Zhang, Rui; Zhu, Jin; Teng, Zhongzhao; Huang, Yuan; Spiga, Filippo; Du, Michael Hong-Fei; Gillard, Jonathan H.; Lu, Qingsheng; Liò, Pietro

    2018-03-01

    Medical imaging examination on patients usually involves more than one imaging modalities, such as Computed Tomography (CT), Magnetic Resonance (MR) and Positron Emission Tomography(PET) imaging. Multimodal imaging allows examiners to benefit from the advantage of each modalities. For example, for Abdominal Aortic Aneurysm, CT imaging shows calcium deposits in the aorta clearly while MR imaging distinguishes thrombus and soft tissues better.1 Analysing and segmenting both CT and MR images to combine the results will greatly help radiologists and doctors to treat the disease. In this work, we present methods on using deep neural network models to perform such multi-modal medical image segmentation. As CT image and MR image of the abdominal area cannot be well registered due to non-affine deformations, a naive approach is to train CT and MR segmentation network separately. However, such approach is time-consuming and resource-inefficient. We propose a new approach to fuse the high-level part of the CT and MR network together, hypothesizing that neurons recognizing the high level concepts of Aortic Aneurysm can be shared across multiple modalities. Such network is able to be trained end-to-end with non-registered CT and MR image using shorter training time. Moreover network fusion allows a shared representation of Aorta in both CT and MR images to be learnt. Through experiments we discovered that for parts of Aorta showing similar aneurysm conditions, their neural presentations in neural network has shorter distances. Such distances on the feature level is helpful for registering CT and MR image.

  11. Invisible fat on CT: making it visible by MRI.

    PubMed

    Ünal, Emre; Karaosmanoğlu, Ali Devrim; Akata, Deniz; Özmen, Mustafa Nasuh; Karçaaltıncaba, Muşturay

    2016-01-01

    Presence of fat in a lesion significantly narrows the differential diagnosis. Small quantities of macroscopic fat and intracellular fat are invisible on computed tomography (CT) and ultrasonography. Magnetic resonance imaging (MRI) can reveal any fatty change in a lesion and can also differentiate macroscopic fat from intracellular and intravoxel fat. Hypodensity on CT may be a sign of invisible fat and MRI can help to diagnose even minute amounts of fat in liver, pancreas, adrenal, musculoskeletal, and omental pseudolesions and lesions. This article will review the superiority of MRI over CT in demonstrating fat in abdominal lesions.

  12. Invisible fat on CT: making it visible by MRI

    PubMed Central

    Ünal, Emre; Karaosmanoğlu, Ali Devrim; Akata, Deniz; Özmen, Mustafa Nasuh; Karçaaltıncaba, Muşturay

    2016-01-01

    Presence of fat in a lesion significantly narrows the differential diagnosis. Small quantities of macroscopic fat and intracellular fat are invisible on computed tomography (CT) and ultrasonography. Magnetic resonance imaging (MRI) can reveal any fatty change in a lesion and can also differentiate macroscopic fat from intracellular and intravoxel fat. Hypodensity on CT may be a sign of invisible fat and MRI can help to diagnose even minute amounts of fat in liver, pancreas, adrenal, musculoskeletal, and omental pseudolesions and lesions. This article will review the superiority of MRI over CT in demonstrating fat in abdominal lesions. PMID:26782156

  13. Metastatic Neuroblastoma in Adult Patient, Presenting as a Super Scan on 68Ga-DOTANOC PET/CT Imaging.

    PubMed

    Malik, Dharmender; Jois, Abhiram; Singh, Harmandeep; Bora, Girdhar S; Basher, Rajender Kumar; Mittal, Bhagwant Rai

    2017-09-01

    We report a case of 23-year-old man who presented with complaints of progressive abdominal distension for the past 3 months along with the loss of appetite and weight and had a large solid cystic mass in the left half of the abdominal cavity revealed on ultrasonography and contrast-enhanced CT of the abdomen. Subsequent biopsy and histopathology revealed it to be neuroblastoma. Ga-DOTANOC PET/CT scan performed to rule out distant metastasis showed intense radiotracer uptake distributed throughout the skeleton, mimicking a super scan.

  14. Abdominal Adhesions

    MedlinePlus

    ... Clearinghouse What are abdominal adhesions? Abdominal adhesions are bands of fibrous tissue that can form between abdominal ... Esophagus Stomach Large intestine Adhesion Abdominal adhesions are bands of fibrous tissue that can form between abdominal ...

  15. Abdominal Pain

    MedlinePlus

    ... and Recurrent or Functional Abdominal Pain (RAP or FAP) What is abdominal pain? Abdominal pain , or stomachache, ... recurrent abdominal pain (RAP) or functional abdominal pain (FAP)? If your health care provider has ruled out ...

  16. Limited utility of MRA for acute bowel ischemia after portal venous phase CT.

    PubMed

    Shetty, Anup S; Mellnick, Vincent M; Raptis, Constantine; Loch, Ronald; Owen, Joseph; Bhalla, Sanjeev

    2015-10-01

    Mesenteric ischemia and ischemic colitis are uncommon but potentially life-threatening causes of acute abdominal pain. Portal venous phase computed tomography (CT) is routinely ordered in the emergency room setting for abdominal pain, but subsequent MR angiography may be requested for additional evaluation of the mesenteric vasculature. We compare the concordance of CT and magnetic resonance angiography (MRA) for acute bowel ischemia. Thirty-two patients who underwent contrast-enhanced MRA for bowel ischemia after having undergone CT evaluation within the preceding 2 weeks were identified. A retrospective review of imaging, treatment history, surgical, and pathology reports was conducted. Two radiologists each reviewed the imaging studies in a blinded fashion. Ten cases of bowel ischemia were confirmed by endoscopy and/or surgical pathology. CT correctly identified bowel findings in all cases. Intraobserver agreement between CT and MRA for all vessels was 0.68 and 0.63, highest for the superior mesenteric artery. Interobserver agreement was 0.74 for MRA and 0.78 for CT. Vascular findings were only directly mentioned in 10 of 32 CT reports (and 7 of 10 cases with confirmed bowel ischemia). MRA only detected two additional or alternative diagnoses. Portal venous phase CT and MRA demonstrate a high degree of concordance for vascular evaluation. Reviewed CT examinations were sufficient to assess the patency of the mesenteric vasculature, but vascular findings were not reported in most cases. A direct description within the report may have obviated the request for further MR imaging. MRA adds little value after portal venous CT in assessing bowel ischemia.

  17. CT vs. MRCP in choledocholithiasis jaundice.

    PubMed

    Petrescu, I; Bratu, A M; Petrescu, S; Popa, B V; Cristian, D; Burcos, T

    2015-01-01

    Obstructive jaundice can raise problems to diagnostic imaging. The radiologist must choose the most appropriate examination that delivers the most important diagnostic information because the differences between a lithiasic obstruction and a tumoral one are vital. This information helps the surgeon speed up the process of decision-making, because the treatment may be very different in relation to the nature of the obstruction. This study tries to demonstrate the diagnostic accuracy of computed tomography (CT) and magnetic resonance cholangiopancreatography (MRCP) in detecting the obstacle in the common bile duct (CBD) and the possibility of establishing the lithiasic nature of the obstruction. A retrospective analysis was analyzed during an interval of 18 months that included jaundice patients admitted in the General Surgery Department of "Coltea" Clinical Hospital. They were examined by CT scanning and by MRCP, being suspected of choledocholithiasis. 63 patients were included in the study, 34 females and 29 males. 33 CT scans and 30 MRCP exams were performed. CT scan is useful in detecting residual or iterative choledocholithiasis in patients after cholecystectomy, contrast enhanced CT (CECT), being able to differentiate between lithiasic and non-lithiasic obstruction. MRCP delivers important anatomic details of the biliary tree; it is superior to CT in diagnosing the hepatocholedochal lithiasis; MRCP tends to replace endoscopic retrograde cholangiopancreatography (ERCP)--the diagnostic "gold standard" reducing the number of unnecessary invasive diagnostic procedures.

  18. Oral Exams as a Tool for Teaching and Assessment

    ERIC Educational Resources Information Center

    Sayre, Eleanor C.

    2014-01-01

    Oral exams are a fruitful and practical alternative to written exams in small-enrolment Science classes. In an oral exam, the instructor can assess conceptual understanding, problem-solving, scientific communication skills, and a student's philosophy of science. In contrast, a written exam gives a much poorer picture of how students learn and…

  19. Comparison between low (3:1) and high (6:1) pitch for routine abdominal/pelvic imaging with multislice computed tomography.

    PubMed

    Sahani, Dushyant; Saini, Sanjay; D'Souza, Roy V; O'Neill, Mary Jane; Prasad, Srinivasa R; Kalra, Mannudeep K; Halpern, Elkan F; Mueller, Peter

    2003-01-01

    The purpose of this study was to compare the performance of low helical pitch acquisition (3:1) and high helical pitch acquisition (6:1) for routine abdominal/pelvic imaging with multislice computed tomography (CT). Three hundred eighty-four patients referred for abdominal/pelvic CT were examined in a breath-hold on a multislice CT scanner (LightSpeed QX/I; General Electric Medical Systems, Milwaukee, WI). Patients were randomized and scanned with pitch of 3:1 or 6:1 using a constant 140 peak kV and 280-300 mA. Images were reconstructed at a 3.75-mm slice thickness. Direct comparison between the two pitches was possible in a subset of 40 patients who had a follow-up scan performed with the second pitch used in each patient. A comparison was also performed between standard dose CT using a pitch of 6:1 and 20% reduced radiation dose CT using a pitch of 3:1. Two readers performed a blind evaluation using a three-point scale for image quality, anatomic details, and motion artifacts. Statistical analysis was performed using a rank sum test and the Wilcoxon signed rank test. Overall image quality mean scores were 2.5 and 2.3 for a pitch of 3:1 and a pitch of 6:1, respectively (P = 0.134). Likewise, mean anatomic detail and motion artifact scores were 2.5 and 2.6 for a 3:1 pitch and 2.3 and 2.5 for a 6:1 pitch, respectively (P > 0.05). In patients with a direct comparison of the two pitches (with the standard radiation dose as well as with a 20% reduction in milliamperes), no statistically significant difference in the performance of the two pitches was observed (P > 0.05). Image quality with a high pitch (6:1) is acceptable for routine abdominal/pelvic CT.

  20. Sleep and Final Exam Performance in Introductory Physics

    NASA Astrophysics Data System (ADS)

    Coletta, Vincent; Wikholm, Colin; Pascoe, Daniel

    2018-03-01

    Most physics instructors believe that adequate sleep is important in order for students to perform well on problem solving, and many instructors advise students to get plenty of sleep the night before an exam. After years of giving such advice to students at Loyola Marymount University (LMU), one of us decided to find out how many hours students actually do sleep the night before an exam, and how that would relate to their performance. The effect of inadequate sleep on exam performance was explored in a second-semester introductory physics course. At the end of the final exam, students reported the number of hours they slept the night before. Sleep deprivation corresponded to lower final exam scores. The main purpose of this study is to provide evidence that instructors can provide to their students to convince them that their time is better spent sleeping rather than studying all night before an exam.

  1. Physical exam frequency

    MedlinePlus

    How often you need a physical exam; Health maintenance visit; Health screening; Checkup ... illness Recommendations are based on sex and age: Health screening -- women -- age 18 to 39 Health screening -- ...

  2. CT diagnosis of a clinically unsuspected acute appendicitis complicating infectious mononucleosis.

    PubMed

    Zissin, R; Brautbar, O; Shapiro-Feinberg, M

    2001-01-01

    Acute appendicitis is a rare complication of infectious mononucleosis (IM). We describe a patient with IM and splenic rupture with a computerized tomography (CT) diagnosis of acute appendicitis during the acute phase of the infectious disease. Diagnostic imaging features of acute appendicitis were found on an abdominal CT performed for the evaluation of postoperative fever. Histologic examination confirmed the CT diagnosis of the clinically unsuspected acute appendicitis. Our case is unique both for the rarity of this complication and the lack of clinical symptoms.

  3. Adult intestinal intussusception: can abdominal MDCT distinguish an intussusception caused by a lead point?

    PubMed

    Tresoldi, Silvia; Kim, Young H; Blake, Michael A; Harisinghani, Mukesh G; Hahn, Peter F; Baker, Stephen P; Mueller, Peter R; Kandarpa, Krishna

    2008-01-01

    Aim of our study was to assess the ability of computed tomography to distinguish between an intussusception with a lead-point from one without it. Approval was granted by the Institutional Review Board. Ninety-three consecutive patients diagnosed with an intussusception on abdominal CT were classified with or without lead-point by surgery, clinical or radiological follow-up. Two radiologists blinded to the classification independently reviewed the CT images for predefined predictive variables. Non-lead-point intussusception was shorter in length (mean 4.9 vs. 11.1 cm for Reader 1 (R1); mean 4.0 vs. 8.9 cm for Reader 2 (R2), respectively, P < 0.001), smaller in axial diameter (mean 3.0 vs. 4.8 cm for R1; mean 2.8 vs. 4.4 cm for R2, P < 0.001, respectively), less likely associated with obstruction (P = 0.002 R1; P = 0.039 R2) and infiltration (P < 0.001 for R1, P = 0.003 R2) than lead-point intussusception. Abdominal CT is helpful in distinguishing between an intussusception with a lead-point from one without a lead-point. Length, axial diameter, and their product, as well as obstruction and infiltration, all suggest the presence of a lead-point. Analysis of CT findings can reduce unnecessary imaging follow-up or operation.

  4. An evaluation of the use of oral contrast media in abdominopelvic CT.

    PubMed

    Buttigieg, Erica Lauren; Grima, Karen Borg; Cortis, Kelvin; Soler, Sandro Galea; Zarb, Francis

    2014-11-01

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. • Positive oral contrast media are routinely used for abdominopelvic multidetector computed tomography • Experimental study comparing image quality using three different oral contrast materials • Three different oral contrast materials result in comparable CT image quality • Benefits for patients and medical imaging department.

  5. Defining the abdominal radiologist based on the current U.S. job market.

    PubMed

    Hoffman, David H; Rosenkrantz, Andrew B

    2018-03-24

    The purpose of the study is to characterize current practice patterns of abdominal radiologists based on work descriptions within job postings on numerous national radiology specialty websites. Job postings for either "abdominal" or "body" radiologists were searched weekly on five society websites (SAR, SCBT-MR, ARRS, ACR, RSNA) over a 1-year period. Postings were reviewed for various characteristics. Nine hundred and sixteen total ads for 341 unique abdominal radiologist positions were reviewed (34.6% academic, 64.2% private practice, 1.2% other). Postings occurred most commonly in March (12.3%) and least commonly in November (4.8%). States with most positions were Florida (27), California (26), and New York (24). Of postings delineating expectations of specific abdominal modalities, 67.4% mentioned MRI, 58.5% ultrasound, 41.1% fluoroscopy, 14.3% PET, and 54.0% interventions. Additional non-abdominal expectations included general radiology (28.7%), breast imaging (21.1%), and general nuclear medicine (9.7%). Additional skills included prostate MRI (7.0%), OBGYN ultrasound (5.0%), and CT colonoscopy (2.6%). 79.2% required an abdominal imaging fellowship (specifically a body MRI fellowship in 4.1%). By using job postings for abdominal radiologists, we have taken a practical approach to characterizing the current status of this subspecialty, reflecting recent job expectations and requirements. The large majority of positions required a body fellowship, and the positions commonly entailed a variety of skills beyond non-invasive diagnostic abdominal imaging. Of note, expectations of considerable minorities of positions included abdominal interventions, general radiology, and breast imaging. These insights may guide the development of abdominal radiology fellowships and mini-fellowships, as well as assist radiologists entering or returning to the job market.

  6. Diagnostic imaging of blunt abdominal trauma in pediatric patients.

    PubMed

    Miele, Vittorio; Piccolo, Claudia Lucia; Trinci, Margherita; Galluzzo, Michele; Ianniello, Stefania; Brunese, Luca

    2016-05-01

    Trauma is a leading cause of morbidity and mortality in childhood, and blunt trauma accounts for 80-90 % of abdominal injuries. The mechanism of trauma is quite similar to that of the adults, but there are important physiologic differences between children and adults in this field, such as the smaller blood vessels and the high vasoconstrictive response, leading to the spreading of a non-operative management. The early imaging of children undergoing a low-energy trauma can be performed by CEUS, a valuable diagnostic tool to demonstrate solid organ injuries with almost the same sensitivity of CT scans; nevertheless, as for as urinary tract injuries, MDCT remains still the technique of choice, because of its high sensitivity and accuracy, helping to discriminate between an intra-peritoneal form a retroperitoneal urinary leakage, requiring two different managements. The liver is the most common organ injured in blunt abdominal trauma followed by the spleen. Renal, pancreatic, and bowel injuries are quite rare. In this review we present various imaging findings of blunt abdominal trauma in children.

  7. Spontaneous Adrenal Hemorrhage in Pregnancy: A Case Series.

    PubMed

    Gupta, Ankita; Minhas, Ruby; Quant, Hayley S

    2017-01-01

    Background . Abdominal pain during pregnancy has a broad differential diagnosis which includes spontaneous adrenal hemorrhage (SAH). There is scant literature available on optimal mode of delivery in stable patients. Cases . Patient 1 was a 35-year-old nullipara who presented at 36 weeks of gestation with left flank pain. Patient 2 was a 27-year-old multipara at 38 weeks who presented with left upper quadrant pain. Diagnosis of SAH was made by CT scan and both were managed with pain control, serial hemoglobin assessments, and abdominal exams resulting in uncomplicated vaginal deliveries. Conclusion . SAH, although rare, is an important consideration when evaluating abdominal and flank pain in pregnancy. Management options vary from conservative management to surgical intervention depending on the stability of the patient.

  8. Spontaneous Adrenal Hemorrhage in Pregnancy: A Case Series

    PubMed Central

    Minhas, Ruby; Quant, Hayley S.

    2017-01-01

    Background. Abdominal pain during pregnancy has a broad differential diagnosis which includes spontaneous adrenal hemorrhage (SAH). There is scant literature available on optimal mode of delivery in stable patients. Cases. Patient 1 was a 35-year-old nullipara who presented at 36 weeks of gestation with left flank pain. Patient 2 was a 27-year-old multipara at 38 weeks who presented with left upper quadrant pain. Diagnosis of SAH was made by CT scan and both were managed with pain control, serial hemoglobin assessments, and abdominal exams resulting in uncomplicated vaginal deliveries. Conclusion. SAH, although rare, is an important consideration when evaluating abdominal and flank pain in pregnancy. Management options vary from conservative management to surgical intervention depending on the stability of the patient. PMID:28421152

  9. Fully Convolutional Neural Networks Improve Abdominal Organ Segmentation.

    PubMed

    Bobo, Meg F; Bao, Shunxing; Huo, Yuankai; Yao, Yuang; Virostko, Jack; Plassard, Andrew J; Lyu, Ilwoo; Assad, Albert; Abramson, Richard G; Hilmes, Melissa A; Landman, Bennett A

    2018-03-01

    Abdominal image segmentation is a challenging, yet important clinical problem. Variations in body size, position, and relative organ positions greatly complicate the segmentation process. Historically, multi-atlas methods have achieved leading results across imaging modalities and anatomical targets. However, deep learning is rapidly overtaking classical approaches for image segmentation. Recently, Zhou et al. showed that fully convolutional networks produce excellent results in abdominal organ segmentation of computed tomography (CT) scans. Yet, deep learning approaches have not been applied to whole abdomen magnetic resonance imaging (MRI) segmentation. Herein, we evaluate the applicability of an existing fully convolutional neural network (FCNN) designed for CT imaging to segment abdominal organs on T2 weighted (T2w) MRI's with two examples. In the primary example, we compare a classical multi-atlas approach with FCNN on forty-five T2w MRI's acquired from splenomegaly patients with five organs labeled (liver, spleen, left kidney, right kidney, and stomach). Thirty-six images were used for training while nine were used for testing. The FCNN resulted in a Dice similarity coefficient (DSC) of 0.930 in spleens, 0.730 in left kidneys, 0.780 in right kidneys, 0.913 in livers, and 0.556 in stomachs. The performance measures for livers, spleens, right kidneys, and stomachs were significantly better than multi-atlas (p < 0.05, Wilcoxon rank-sum test). In a secondary example, we compare the multi-atlas approach with FCNN on 138 distinct T2w MRI's with manually labeled pancreases (one label). On the pancreas dataset, the FCNN resulted in a median DSC of 0.691 in pancreases versus 0.287 for multi-atlas. The results are highly promising given relatively limited training data and without specific training of the FCNN model and illustrate the potential of deep learning approaches to transcend imaging modalities.

  10. Fully convolutional neural networks improve abdominal organ segmentation

    NASA Astrophysics Data System (ADS)

    Bobo, Meg F.; Bao, Shunxing; Huo, Yuankai; Yao, Yuang; Virostko, Jack; Plassard, Andrew J.; Lyu, Ilwoo; Assad, Albert; Abramson, Richard G.; Hilmes, Melissa A.; Landman, Bennett A.

    2018-03-01

    Abdominal image segmentation is a challenging, yet important clinical problem. Variations in body size, position, and relative organ positions greatly complicate the segmentation process. Historically, multi-atlas methods have achieved leading results across imaging modalities and anatomical targets. However, deep learning is rapidly overtaking classical approaches for image segmentation. Recently, Zhou et al. showed that fully convolutional networks produce excellent results in abdominal organ segmentation of computed tomography (CT) scans. Yet, deep learning approaches have not been applied to whole abdomen magnetic resonance imaging (MRI) segmentation. Herein, we evaluate the applicability of an existing fully convolutional neural network (FCNN) designed for CT imaging to segment abdominal organs on T2 weighted (T2w) MRI's with two examples. In the primary example, we compare a classical multi-atlas approach with FCNN on forty-five T2w MRI's acquired from splenomegaly patients with five organs labeled (liver, spleen, left kidney, right kidney, and stomach). Thirty-six images were used for training while nine were used for testing. The FCNN resulted in a Dice similarity coefficient (DSC) of 0.930 in spleens, 0.730 in left kidneys, 0.780 in right kidneys, 0.913 in livers, and 0.556 in stomachs. The performance measures for livers, spleens, right kidneys, and stomachs were significantly better than multi-atlas (p < 0.05, Wilcoxon rank-sum test). In a secondary example, we compare the multi-atlas approach with FCNN on 138 distinct T2w MRI's with manually labeled pancreases (one label). On the pancreas dataset, the FCNN resulted in a median DSC of 0.691 in pancreases versus 0.287 for multi-atlas. The results are highly promising given relatively limited training data and without specific training of the FCNN model and illustrate the potential of deep learning approaches to transcend imaging modalities. 1

  11. A New CT-Guided Modified Trocar Technique for Drainage of Difficult Locations Abscesses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyng, Chiang J., E-mail: chiangjengtyng@gmail.com; Amoedo, Maurício K.; Bohrer, Yves

    PurposeComputed tomography (CT) is commonly used to guide drainage of deep-seated abdominal fluid collections. However, in some cases, these collections seem to be inaccessible due to surrounding organs or their being in difficult locations. The aim of this study is to describe a modified Trocar technique to drain collections in difficult locations, especially those in the subphrenic space, without passing through intervening organs.Materials and MethodsThis retrospective case series study describes seven inpatients who underwent CT-guided drainage using a modified Trocar technique for abscesses that are difficult to access percutaneously. All patients provided written informed consent prior to the procedure. Aftermore » placement of a 12–14F catheter inside the peritoneum, the Trocar stylet was removed so that the tip of the catheter became blunt and flexible to avoid injury to organs and structures in the catheter route, and the catheter was slowly advanced towards the collection using CT guidance and tactile sensation. After reaching the target, the stylet was reintroduced to enter the abscess wall.ResultsAll procedures were performed using an anterior abdominal wall access with adequate catheter positioning and resulted in clinical status improvement in the days after the drainage. No complications related to the procedure were identified in any of the patients.ConclusionsThe modified Trocar technique for percutaneous CT-guided drainage of abdominal abscesses may be feasible for lesions that are difficult to access with conventional methods.« less

  12. X-Ray Exam: Neck (For Parents)

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Neck KidsHealth / For Parents / X-Ray Exam: Neck What's in this article? What ... español Radiografía: cuello What It Is A neck X-ray is a safe and painless test that ...

  13. The Provision of Diabetes-Monitoring Exams to Older Latinos

    PubMed Central

    Herrera, Angelica P.; Lee Smith, Matthew; Ory, Marcia G.; Rodriguez, Hector P.; Warre, Ruth; Thompson, Wesley K.; Azcue, Annette; Romero, Jairo A.

    2012-01-01

    Objectives To explore factors associated with the provision of diabetes-monitoring practices among older Latinos with type 2 diabetes. Method Data from 547 Latinos (≥55 years) were analyzed from the 2007 California Health Interview Survey. Multivariate logistic regression modeled the relationship between health status and sociodemographic factors and the receipt of semiannual HbA1c tests, annual foot exams, and annual retinal exams. Results The majority of older Latino diabetics received foot exams (87%) and retinal exams (77%), but the provision of semiannual HbA1c tests (30%) was low. Higher English-language proficiency and health insurance coverage were associated with the provision of HbA1c tests and foot exams, but not retinal exams. Insulin therapy was positively associated with semiannual HbA1c testing, but negatively associated with foot exams. Discussion There are considerable missed opportunities in the provision of diabetes monitoring for older Latinos, particularly those with limited English proficiency, less comprehensive insurance, and noninsulin therapy. PMID:21948771

  14. Giving bonus points based on oral exams

    NASA Astrophysics Data System (ADS)

    Ehrlich, Robert

    2007-04-01

    A pedagogical experiment of giving bonus points based on oral exams in an introductory physics course is described. The orals covered the questions on a written exam that had just been graded and returned to the class. Although the performance of most students on the oral exams was fair at best, the value of bonus point orals would appear to be considerable, even though it may not be applicable to large classes and have other important disadvantages.

  15. Cognitive Difficulty and Format of Exams Predicts Gender and Socioeconomic Gaps in Exam Performance of Students in Introductory Biology Courses.

    PubMed

    Wright, Christian D; Eddy, Sarah L; Wenderoth, Mary Pat; Abshire, Elizabeth; Blankenbiller, Margaret; Brownell, Sara E

    2016-01-01

    Recent reform efforts in undergraduate biology have recommended transforming course exams to test at more cognitively challenging levels, which may mean including more cognitively challenging and more constructed-response questions on assessments. However, changing the characteristics of exams could result in bias against historically underserved groups. In this study, we examined whether and to what extent the characteristics of instructor-generated tests impact the exam performance of male and female and middle/high- and low-socioeconomic status (SES) students enrolled in introductory biology courses. We collected exam scores for 4810 students from 87 unique exams taken across 3 yr of the introductory biology series at a large research university. We determined the median Bloom's level and the percentage of constructed-response questions for each exam. Despite controlling for prior academic ability in our models, we found that males and middle/high-SES students were disproportionately favored as the Bloom's level of exams increased. Additionally, middle/high-SES students were favored as the proportion of constructed-response questions on exams increased. Given that we controlled for prior academic ability, our findings do not likely reflect differences in academic ability level. We discuss possible explanations for our findings and how they might impact how we assess our students. © 2016 C. D. Wright, S. L. Eddy, et al. CBE—Life Sciences Education © 2016 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  16. Breast self-exam

    MedlinePlus

    Self-examination of the breast; BSE; Breast cancer - BSE; Breast cancer screening - self exam ... chap 15. US Preventive Services Task Force website. Breast cancer: screening. www.uspreventiveservicestaskforce.org/Page/Document/UpdateSummaryFinal/breast- ...

  17. Ocular Health (OH) Fundoscope Exam

    NASA Image and Video Library

    2013-06-05

    ISS036-E-006520 (5 June 2013) --- NASA astronaut Karen Nyberg, Expedition 36 flight engineer, conducts an ocular health exam on herself in the Destiny laboratory of the Earth-orbiting International Space Station. NASA astronaut Chris Cassidy, flight engineer, nearby but out of frame, assisted in the testing, part of a suite of eye exams carried out over a two-day period on various crew members to gather information on intraocular pressure and eye anatomy.

  18. Abdominal tap

    MedlinePlus

    Peritoneal tap; Paracentesis; Ascites - abdominal tap; Cirrhosis - abdominal tap; Malignant ascites - abdominal tap ... abdominal cavity ( most often cancer of the ovaries ) Cirrhosis of the liver Damaged bowel Heart disease Infection ...

  19. SPET/CT image co-registration in the abdomen with a simple and cost-effective tool.

    PubMed

    Förster, Gregor J; Laumann, Christina; Nickel, Otmar; Kann, Peter; Rieker, Olaf; Bartenstein, Peter

    2003-01-01

    Fusion of morphology and function has been shown to improve diagnostic accuracy in many clinical circumstances. Taking this into account, a number of instruments combining computed tomography (CT) with positron emission tomography (PET) or single-photon emission tomography (SPET) are appearing on the market. The aim of this study was to evaluate a simple and cost-effective approach to generate fusion images of similar quality. For the evaluation of the proposed approach, patients with neuroendocrine abdominal tumours with liver metastases were chosen, since the exact superimposition in the abdomen is more difficult than in other regions. Five hours following the injection of 110 MBq (111)In-DTPA-octreotide, patients were fixed in a vacuum cushion (MED-TEC, Vac-Loc) and investigated with helical CT in a mid-inspiration position ( n=14). Directly following the CT, a SPET study (SPET1) of the abdominal region was performed without changing the position of the patient. A second SPET study (SPET2), 24 h p.i., was acquired after repositioning the patient in his or her individually moulded vacuum cushion. A total of nine markers suitable for imaging with CT and SPET were fixed on the cushion. Datasets were fused by means of internal landmarks (e.g. metastases or margin of abdominal organs) or by the external markers. Image fusion using external markers was fast and easy to handle compared with the use of internal landmarks. Using this technique, all lesions detectable by SPET ( n=28) appeared exactly superpositioned on the respective CT morphology by visual inspection. Image fusion of CT/SPET1 and CT/SPET2 showed a mean deviation of the external markers that in the former case was smaller than the voxel size of 4.67 mm: 4.17+/-0.61 (CT/SPET1; +/-SD) and 5.52+/-1.56 mm (CT/SPET2), respectively. Using internal landmarks, the mean deviation of the chosen landmarks was 6.47+/-1.37 and 7.78+/-1.21 mm. Vector subtraction of corresponding anatomical points of the CT and the re

  20. Clinical outcomes of pediatric patients with acute abdominal pain and incidental findings of free intraperitoneal fluid on diagnostic imaging.

    PubMed

    Matz, Samantha; Connell, Mary; Sinha, Madhumita; Goettl, Christopher S; Patel, Palak C; Drachman, David

    2013-09-01

    The presence of free intraperitoneal fluid on diagnostic imaging (sonography or computed tomography [CT]) may indicate an acute inflammatory process in children with abdominal pain in a nontraumatic setting. Although clinical outcomes of pediatric trauma patients with free fluid on diagnostic examinations without evidence of solid-organ injury have been studied, similar studies in the absence of trauma are rare. Our objective was to study clinical outcomes of children with acute abdominal pain of nontraumatic etiology and free intraperitoneal fluid on diagnostic imaging (abdominal/pelvic sonography, CT, or both). We conducted a retrospective review of medical records of children aged 0 to 18 years presenting to a pediatric emergency department with acute abdominal pain (nontraumatic) between April 2008 and March 2009. Patients with intraperitoneal free fluid on imaging were divided into 2 groups: group I, imaging suggestive of an intra-abdominal surgical condition such as appendicitis; and group II, no evidence of an acute surgical condition on imaging, including patients with equivocal studies. Computed tomograms and sonograms were reviewed by a board-certified radiologist, and the free fluid volume was quantitated. Of 1613 patients who underwent diagnostic imaging, 407 were eligible for the study; 134 (33%) had free fluid detected on diagnostic imaging. In patients with both sonography and CT, there was a significant correlation in the free fluid volume (r = 0.79; P < .0005). A significantly greater number of male patients with free fluid had a surgical condition identified on imaging (57.4% versus 25%; P < .001). Children with free fluid and an associated condition on imaging were more likely to have surgery (94.4% versus 6.3%; P < .001). We found clinical outcomes (surgical versus nonsurgical) to be most correlated with a surgical diagnosis on diagnostic imaging and not with the amount of fluid present.

  1. Staged abdominal re-operation for abdominal trauma.

    PubMed

    Taviloglu, Korhan

    2003-07-01

    To review the current developments in staged abdominal re-operation for abdominal trauma. To overview the steps of damage control laparotomy. The ever increasing importance of the resuscitation phase with current intensive care unit (ICU) support techniques should be emphasized. General surgeons should be familiar to staged abdominal re-operation for abdominal trauma and collaborate with ICU teams, interventional radiologists and several other specialties to overcome this entity.

  2. A navigation system for flexible endoscopes using abdominal 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Hoffmann, R.; Kaar, M.; Bathia, Amon; Bathia, Amar; Lampret, A.; Birkfellner, W.; Hummel, J.; Figl, M.

    2014-09-01

    A navigation system for flexible endoscopes equipped with ultrasound (US) scan heads is presented. In contrast to similar systems, abdominal 3D-US is used for image fusion of the pre-interventional computed tomography (CT) to the endoscopic US. A 3D-US scan, tracked with an optical tracking system (OTS), is taken pre-operatively together with the CT scan. The CT is calibrated using the OTS, providing the transformation from CT to 3D-US. Immediately before intervention a 3D-US tracked with an electromagnetic tracking system (EMTS) is acquired and registered intra-modal to the preoperative 3D-US. The endoscopic US is calibrated using the EMTS and registered to the pre-operative CT by an intra-modal 3D-US/3D-US registration. Phantom studies showed a registration error for the US to CT registration of 5.1 mm ± 2.8 mm. 3D-US/3D-US registration of patient data gave an error of 4.1 mm compared to 2.8 mm with the phantom. From this we estimate an error on patient experiments of 5.6 mm.

  3. Enhanced Security for Online Exams Using Group Cryptography

    ERIC Educational Resources Information Center

    Jung, I. Y.; Yeom, H. Y.

    2009-01-01

    While development of the Internet has contributed to the spread of online education, online exams have not been widely adopted. An online exam is defined here as one that takes place over the insecure Internet, and where no proctor is in the same location as the examinees. This paper proposes an enhanced secure online exam management environment…

  4. Exit Exams: Decreases or Increases the Dropout Rate

    ERIC Educational Resources Information Center

    Barnes, Teresa A.

    2009-01-01

    The purpose of this paper was to examine the impact of exit exams on the dropout rate. Data was gathered from several research articles. The most impressionable research revealed exit exams have a negative effect on minorities, especially black males. Results indicate by 2012, that exit exams in 25 states will affect 81 percent of minority high…

  5. Neck circumference as a measure of neck fat and abdominal visceral fat in Chinese adults.

    PubMed

    Li, Hong-Xing; Zhang, Fen; Zhao, Dong; Xin, Zhong; Guo, Shu-Qin; Wang, Shu-Mei; Zhang, Jian-Jun; Wang, Jun; Li, Yan; Yang, Guang-Ran; Yang, Jin-Kui

    2014-04-04

    Visceral adipose tissue (VAT) is a unique pathogenic fatty deposit, in that it is closely correlated with risk of cardiovascular diseases. The present study is to investigate the usefulness of neck circumference (NC) to indicate VAT. Participants aged 35 to 75 years who had taken abdomen and neck computer tomography (CT) examination were included in this study. Neck adipose tissue, abdominal VAT and subcutaneous adipose tissue (SAT) areas, as well as sagittal abdominal diameter (SAD) were measured by CT. Body anthropometrics and metabolic parameters including blood glucose, lipid profiles and blood pressure were also measured. A lower abdomen CT examination was carried out on a total of 177 patients (87 male and 90 female) with a mean age of 59 years. Of the 177 participants, 15 men and 15 women also took a neck CT examination. With a comparable age and BMI, neck adipose area was correlated with abdominal VAT area significantly in men (r = 0.57, p = 0.028) and women (r = 0.53, p = 0.041). NC is positively correlated with VAT both in men (r = 0.49, p < 0.001) and women (r = 0.25, p = 0.012). Meanwhile, SAD is the best predictor for visceral fat both in men (r = 0.83, p < 0.001) and women (r = 0.73, p < 0.001). Body mass index (BMI), waist circumference (WC), and waist to height ratio (WHtR) correlated significantly with VAT both in men and women (r = 0.68, 0.42, 0.46 in men and 0.50, 0.23, 0.39 in women, p < 0.001), while waist hip ratio (WHR) displayed the weakest least correlation in men (r = 0.32, p = 0.001) and no correlation in women (r = 0.08, p = 0.442). Additionally, BMI was more strongly correlated with VAT than NC in both sexes (both p < 0.01). Significant correlation between NC and VAT was present in Chinese men and women, which may be accounted by the fact that neck fat area is significantly correlated with abdominal VAT. Meanwhile, SAD is the best predictor for visceral fat in

  6. Shape-intensity prior level set combining probabilistic atlas and probability map constrains for automatic liver segmentation from abdominal CT images.

    PubMed

    Wang, Jinke; Cheng, Yuanzhi; Guo, Changyong; Wang, Yadong; Tamura, Shinichi

    2016-05-01

    Propose a fully automatic 3D segmentation framework to segment liver on challenging cases that contain the low contrast of adjacent organs and the presence of pathologies from abdominal CT images. First, all of the atlases are weighted in the selected training datasets by calculating the similarities between the atlases and the test image to dynamically generate a subject-specific probabilistic atlas for the test image. The most likely liver region of the test image is further determined based on the generated atlas. A rough segmentation is obtained by a maximum a posteriori classification of probability map, and the final liver segmentation is produced by a shape-intensity prior level set in the most likely liver region. Our method is evaluated and demonstrated on 25 test CT datasets from our partner site, and its results are compared with two state-of-the-art liver segmentation methods. Moreover, our performance results on 10 MICCAI test datasets are submitted to the organizers for comparison with the other automatic algorithms. Using the 25 test CT datasets, average symmetric surface distance is [Formula: see text] mm (range 0.62-2.12 mm), root mean square symmetric surface distance error is [Formula: see text] mm (range 0.97-3.01 mm), and maximum symmetric surface distance error is [Formula: see text] mm (range 12.73-26.67 mm) by our method. Our method on 10 MICCAI test data sets ranks 10th in all the 47 automatic algorithms on the site as of July 2015. Quantitative results, as well as qualitative comparisons of segmentations, indicate that our method is a promising tool to improve the efficiency of both techniques. The applicability of the proposed method to some challenging clinical problems and the segmentation of the liver are demonstrated with good results on both quantitative and qualitative experimentations. This study suggests that the proposed framework can be good enough to replace the time-consuming and tedious slice-by-slice manual

  7. SU-G-IeP2-10: Lens Dose Reduction by Patient Position Modification During Neck CT Exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mosher, E; Lee, C; Butman, J

    Purpose: Irradiation of the lens during a neck CT may increase a patient’s risk of developing cataracts later in life. Radiologists and technologists at the National Institutes of Health Clinical Center (NIHCC) have developed new CT imaging protocols that include a reduction in scan range and modifying neck positioning using a head tilt. This study will evaluate the efficacy of this protocol in the reduction of lens dose. Methods: We retrieved CT images of five male patients who had two sets of CT images: before and after the implementation of the new protocol. The lens doses before the new protocolmore » were calculated using an in-house CT dose calculator, National Cancer Institute dosimetry system for CT (NCICT), where computational human phantoms with no head tilt are included. We also calculated the lens dose for the patient CT conducted after the new protocol by using an adult male computational phantom with the neck position deformed to match the angle of the head tilt. We also calculated the doses to other radiosensitive organs including the globes of the eye, brain, pituitary gland and salivary glands before and after head tilt. Results: Our dose calculations demonstrated that modifying neck position reduced dose to the lens by 89% on average (range: 86–96%). Globe, brain, pituitary and salivary gland doses also decreased by an average of 65% (51–95%), 38% (−8–66%), 34% (−43–84%) and 14% (13–14%), respectively. The new protocol resulted in a nearly ten-fold decrease in lens dose. Conclusion: The use of a head tilt and scan range reduction is an easy and effective method to reduce radiation exposure to the lens and other radiosensitive organs, while still allowing for the inclusion of critical neck structures in the CT image. We are expanding our study to a total of 10 males and 10 females.« less

  8. [Gas gangrene of the abdominal wall due to underlying GI pathology: seven cases].

    PubMed

    Monneuse, O; Gruner, L; Barth, X; Malick, P; Timsit, M; Gignoux, B; Tissot, E

    2007-01-01

    Gas gangrene of the abdominal wall is a rare clinical occurrence with high rates of morbidity and mortality. The primary source of the infection is often unknown. To analyze the primary underlying intestinal etiologies and diagnostic approaches of gas gangrene of the abdominal wall, and to highlight specific treatment problems, particularly that of constructing a colostomy exteriorized through a massively infected abdominal wall. Seven cases of abdominal wall gas gangrene due to a gastrointestinal etiology were identified. (Cases arising from proctologic sources or related to recent abdominal surgery were excluded.) During the same period, 39 other patients presenting with abdominal wall gangrene from non-intestinal sources were treated. The etiologies were: perforated sigmoid diverticulitis (n=2), perforated appendicitis (n=1), acute pancreatitis with associated cecal perforation (n=1), and perforated colorectal cancer (n=3). Four of the seven patients died despite treatment (mortality of 57%). The clinical presentations of these seven cases demonstrate that a GI source must be suspected whenever a patient presents with abdominal wall gas gangrene, even when there are no specific GI symptoms. Imaging, particularly with CT scan, is essential both to visualize the extent of tissue necrosis and to reveal underlying primary GI pathology. This optimizes the surgical approach both by allowing for complete debridement and drainage of infected tissue, and by focussing the intervention on correction of the underlying primary GI source of infection.

  9. [Chance fracture missed by convencional CT: Presentation of a clinical course].

    PubMed

    Pérez Suárez, Esther; Carceller, Fernando; García Salido, Alberto; Serrano, Ana; Casado, Juan

    2011-02-01

    Bending-disruption fractures of the vertebral body are called Chance fracture. In some cases these fractures may not be noticeable with a CT scan. A 9 years-old boy suffered a frontal collision while traveling in the back seat of a car. The child was secured by the safetybelt, without a child car seat or elevator adapted to his height. He had abdominal skin lesions in the physical exploration compatible with a belt mark. Conventional thoraco- abdominal CT scan did not show any vertebral fracture. As the clinical suspicion persisted, lateral plain radiography of the lumbar column was performed showing a Chance fracture in L2, confirmed by MRI. Chance fracture is typically seen in children under 12 years less than 135 cm height and with injuries associated with the belt after a traffic accident. This type of fractures may go unnoticed in a conventional CT scan so clinical suspicion must lead us to further work-up. The MRI is the gold standard for the diagnosis. This case remarks the importance of the use of homologated elevated seat devices in older children.

  10. Estimating thyroid dose in pediatric CT exams from surface dose measurement

    NASA Astrophysics Data System (ADS)

    Al-Senan, Rani; Mueller, Deborah L.; Hatab, Mustapha R.

    2012-07-01

    The purpose of this study was to investigate the possibility of estimating pediatric thyroid doses from CT using surface neck doses. Optically stimulated luminescence dosimeters were used to measure the neck surface dose of 25 children ranging in ages between one and three years old. The neck circumference for each child was measured. The relationship between obtained surface doses and thyroid dose was studied using acrylic phantoms of various sizes and with holes of different depths. The ratios of hole-to-surface doses were used to convert patients' surface dose to thyroid dose. ImPACT software was utilized to calculate thyroid dose after applying the appropriate age correction factors. A paired t-test was performed to compare thyroid doses from our approach and ImPACT. The ratio of thyroid to surface dose was found to be 1.1. Thyroid doses ranged from 20 to 80 mGy. Comparison showed no statistical significance (p = 0.18). In addition, the average of surface dose variation along the z-axis in helical scans was studied and found to range between 5% (in 10 cm diameter phantom/24 mm collimation/pitch 1.0) and 8% (in 16 cm diameter phantom/12 mm collimation/pitch 0.7). We conclude that surface dose is an acceptable predictor for pediatric thyroid dose from CT. The uncertainty due to surface dose variability may be reduced if narrower collimation is used with a pitch factor close to 1.0. Also, the results did not show any effect of thyroid depth on the measured dose.

  11. Utility of PET/CT to Evaluate Retroperitoneal Lymph Node Metastasis in High-Risk Endometrial Cancer: Results of ACRIN 6671/GOG 0233 Trial.

    PubMed

    Atri, Mostafa; Zhang, Zheng; Dehdashti, Farrokh; Lee, Susanna I; Marques, Helga; Ali, Shamshad; Koh, Wui-Jin; Mannel, Robert S; DiSilvestro, Paul; King, Stephanie A; Pearl, Michael; Zhou, XunClare; Plante, Marie; Moxley, Katherine M; Gold, Michael

    2017-05-01

    Purpose To assess the diagnostic accuracy of fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) combined with diagnostic contrast material-enhanced computed tomography (CT) in detecting lymph node (LN) metastasis in high-risk endometrial cancer. Materials and Methods This prospective multicenter HIPAA-compliant study had institutional review board approval, and all participants gave written informed consent. Data were accrued between January 2010 and June 2013. Patients underwent PET/CT and pelvic and abdominal lymphadenectomy. Two hundred seven of 215 enrolled patients had PET/CT and pathologic examination results for the abdomen and pelvis. Mean patient age was 62.7 years ± 9.6 (standard deviation). Data in all 23 patients with a positive abdominal examination and in 26 randomly selected patients with a negative abdominal examination were used for this central reader study. Seven independent blinded readers reviewed diagnostic CT and PET/CT results in different sessions 1 month apart. Accuracy was calculated at the participant level, correlating abdominal (right and left para-aortic and common iliac) and pelvic (right and left external iliac and obturator) LN regions with pathologic results, respecting laterality. Reader-average sensitivities, specificities, and areas under the receiver operating characteristic curve (AUCs) of PET/CT and diagnostic CT were compared. Power calculation was for sensitivity and specificity in the abdomen. Results Sensitivities of PET/CT versus diagnostic CT for the detection of LN metastasis were 0.65 (95% confidence interval [CI]: 0.57, 0.72) versus 0.50 (95% CI: 0.43, 0.58) (P = .01) in the abdomen and 0.65 (95% CI: 0.57, 0.72) versus 0.48 (95% CI: 0.41, 0.56) (P = .004) in the pelvis. Corresponding specificities were 0.88 (95% CI: 0.83, 0.92) versus 0.93 (95% CI: 0.89, 0.96) (P = .11) and 0.93 (95% CI: 0.86, 0.96) versus 0.89 (95% CI: 0.82, 0.94) (P = .27), and AUCs were 0.78 (95% CI: 0.66, 0.89) versus 0

  12. Utility of PET/CT to Evaluate Retroperitoneal Lymph Node Metastasis in High-Risk Endometrial Cancer: Results of ACRIN 6671/GOG 0233 Trial

    PubMed Central

    Zhang, Zheng; Dehdashti, Farrokh; Lee, Susanna I.; Marques, Helga; Ali, Shamshad; Koh, Wui-Jin; Mannel, Robert S.; DiSilvestro, Paul; King, Stephanie A.; Pearl, Michael; Zhou, XunClare; Plante, Marie; Moxley, Katherine M.; Gold, Michael

    2017-01-01

    Purpose To assess the diagnostic accuracy of fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) combined with diagnostic contrast material–enhanced computed tomography (CT) in detecting lymph node (LN) metastasis in high-risk endometrial cancer. Materials and Methods This prospective multicenter HIPAA-compliant study had institutional review board approval, and all participants gave written informed consent. Data were accrued between January 2010 and June 2013. Patients underwent PET/CT and pelvic and abdominal lymphadenectomy. Two hundred seven of 215 enrolled patients had PET/CT and pathologic examination results for the abdomen and pelvis. Mean patient age was 62.7 years ± 9.6 (standard deviation). Data in all 23 patients with a positive abdominal examination and in 26 randomly selected patients with a negative abdominal examination were used for this central reader study. Seven independent blinded readers reviewed diagnostic CT and PET/CT results in different sessions 1 month apart. Accuracy was calculated at the participant level, correlating abdominal (right and left para-aortic and common iliac) and pelvic (right and left external iliac and obturator) LN regions with pathologic results, respecting laterality. Reader-average sensitivities, specificities, and areas under the receiver operating characteristic curve (AUCs) of PET/CT and diagnostic CT were compared. Power calculation was for sensitivity and specificity in the abdomen. Results Sensitivities of PET/CT versus diagnostic CT for the detection of LN metastasis were 0.65 (95% confidence interval [CI]: 0.57, 0.72) versus 0.50 (95% CI: 0.43, 0.58) (P = .01) in the abdomen and 0.65 (95% CI: 0.57, 0.72) versus 0.48 (95% CI: 0.41, 0.56) (P = .004) in the pelvis. Corresponding specificities were 0.88 (95% CI: 0.83, 0.92) versus 0.93 (95% CI: 0.89, 0.96) (P = .11) and 0.93 (95% CI: 0.86, 0.96) versus 0.89 (95% CI: 0.82, 0.94) (P = .27), and AUCs were 0.78 (95% CI: 0.66, 0.89) versus 0

  13. Distinguishing infected from noninfected abdominal fluid collections after surgery: an imaging, clinical, and laboratory-based scoring system.

    PubMed

    Gnannt, Ralph; Fischer, Michael A; Baechler, Thomas; Clavien, Pierre-Alain; Karlo, Christoph; Seifert, Burkhardt; Lesurtel, Mickael; Alkadhi, Hatem

    2015-01-01

    Mortality from abdominal abscesses ranges from 30% in treated cases up to 80% to 100% in patients with undrained or nonoperated abscesses. Various computed tomographic (CT) imaging features have been suggested to indicate infection of postoperative abdominal fluid collections; however, features are nonspecific and substantial overlap between infected and noninfected collections exists. The purpose of this study was to develop and validate a scoring system on the basis of CT imaging findings as well as laboratory and clinical parameters for distinguishing infected from noninfected abdominal fluid collections after surgery. The score developmental cohort included 100 consecutive patients (69 men, 31 women; mean age, 58 ± 17 years) who underwent portal-venous phase CT within 24 hours before CT-guided intervention of postoperative abdominal fluid collections. Imaging features included attenuation (Hounsfield unit [HU]), volume, wall enhancement and thickness, fat stranding, as well as entrapped gas of fluid collections. Laboratory and clinical parameters included diabetes, intake of immunosuppressive drugs, body temperature, C-reactive protein, and leukocyte blood cell count. The score was validated in a separate cohort of 30 consecutive patients (17 men, 13 women; mean age, 51 ± 15 years) with postoperative abdominal fluid collections. Microbiologic analysis from fluid samples served as the standard of reference. Diabetes, body temperature, C-reactive protein, attenuation of the fluid collection (in HUs), wall enhancement and thickness of the wall, adjacent fat stranding, as well as entrapped gas within the fluid collection were significantly different between infected and noninfected collections (P < 0.001). Multiple logistic regression analysis revealed diabetes, C-reactive protein, attenuation of the fluid collection (in HUs), as well as entrapped gas as significant independent predictors of infection (P < 0.001) and thus was selected for constructing a scoring

  14. Potential for adult-based epidemiological studies to characterize overall cancer risks associated with a lifetime of CT scans.

    PubMed

    Shuryak, Igor; Lubin, Jay H; Brenner, David J

    2014-06-01

    Recent epidemiological studies have suggested that radiation exposure from pediatric CT scanning is associated with small excess cancer risks. However, the majority of CT scans are performed on adults, and most radiation-induced cancers appear during middle or old age, in the same age range as background cancers. Consequently, a logical next step is to investigate the effects of CT scanning in adulthood on lifetime cancer risks by conducting adult-based, appropriately designed epidemiological studies. Here we estimate the sample size required for such studies to detect CT-associated risks. This was achieved by incorporating different age-, sex-, time- and cancer type-dependent models of radiation carcinogenesis into an in silico simulation of a population-based cohort study. This approach simulated individual histories of chest and abdominal CT exposures, deaths and cancer diagnoses. The resultant sample sizes suggest that epidemiological studies of realistically sized cohorts can detect excess lifetime cancer risks from adult CT exposures. For example, retrospective analysis of CT exposure and cancer incidence data from a population-based cohort of 0.4 to 1.3 million (depending on the carcinogenic model) CT-exposed UK adults, aged 25-65 in 1980 and followed until 2015, provides 80% power for detecting cancer risks from chest and abdominal CT scans.

  15. Exam anxiety in the undergraduate medical students of Taibah University.

    PubMed

    Khoshhal, Khalid I; Khairy, Gamal A; Guraya, Salman Y; Guraya, Shaista S

    2017-04-01

    Assessment is perceived to create highly stressful environment among medical students. Several studies have reported exam-related anxiety symptoms but the contributing factors seem to differ across institutions. This study aimed to determine the prevalence of exam anxiety, gender differences and the variables that moderate exam anxiety among students of a Saudi medical school. A cross-section study was done on 5th year medical students by administering a 12-statement self-administered questionnaire. The degree of exam anxiety was gauged by a visual analog scale. Of 125 students, 111 responded (response rate 89%). About 65% students experienced exam anxiety due to various reasons. Studying all night before exam (28 students; 25.2%) and extensive course load (26 students; 23.4%) were the major confounding factors. Female students experienced more stress due to extensive course load as compared with male students (p = .00). The data about the identified risk factors for exam anxiety can help medical educators to deeply understand the reasons for exam anxiety. There is a need to reassess the amount of study material in undergraduate medical curricula and students need to organize their time management skills to cope with exam anxiety.

  16. MO-E-17A-08: Attenuation-Based Size Adjusted, Scanner-Independent Organ Dose Estimates for Head CT Exams: TG 204 for Head CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMillan, K; Bostani, M; Cagnon, C

    Purpose: AAPM Task Group 204 described size specific dose estimates (SSDE) for body scans. The purpose of this work is to use a similar approach to develop patient-specific, scanner-independent organ dose estimates for head CT exams using an attenuation-based size metric. Methods: For eight patient models from the GSF family of voxelized phantoms, dose to brain and lens of the eye was estimated using Monte Carlo simulations of contiguous axial scans for 64-slice MDCT scanners from four major manufacturers. Organ doses were normalized by scannerspecific 16 cm CTDIvol values and averaged across all scanners to obtain scanner-independent CTDIvol-to-organ-dose conversion coefficientsmore » for each patient model. Head size was measured at the first slice superior to the eyes; patient perimeter and effective diameter (ED) were measured directly from the GSF data. Because the GSF models use organ identification codes instead of Hounsfield units, water equivalent diameter (WED) was estimated indirectly. Using the image data from 42 patients ranging from 2 weeks old to adult, the perimeter, ED and WED size metrics were obtained and correlations between each metric were established. Applying these correlations to the GSF perimeter and ED measurements, WED was calculated for each model. The relationship between the various patient size metrics and CTDIvol-to-organ-dose conversion coefficients was then described. Results: The analysis of patient images demonstrated the correlation between WED and ED across a wide range of patient sizes. When applied to the GSF patient models, an exponential relationship between CTDIvol-to-organ-dose conversion coefficients and the WED size metric was observed with correlation coefficients of 0.93 and 0.77 for the brain and lens of the eye, respectively. Conclusion: Strong correlation exists between CTDIvol normalized brain dose and WED. For the lens of the eye, a lower correlation is observed, primarily due to surface dose variations

  17. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, S; Wang, Y; Weng, H

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiationmore » dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.« less

  18. The accuracy of combined physical examination and ultrasonography for the detection of abdominal aorta aneurysm.

    PubMed

    Cârstea, Doina; Streba, Letiţia Adela Maria; Glodeanu, Adina; Cârstea, A P; Vancu, Mihaela; Ninulescu, Ana-Maria

    2008-01-01

    Atherosclerosis is the most frequent cause in the appearance of an abdominal aorta aneurysm (AAA) and plays an important role in his development. Most AAA does not cause any symptoms, especially when talking about elderly patients, however, many of those aneurysms can be detected during physical examination. Their detection is very important because the natural evolution and the major reason in treating AAA is their tendency to rupture. We present the case of an adult man with a complex clinical pathology, but not related to the AAA. The diagnosis of the AAA has been suspicion through palpation, and the abdominal ultrasound exam confirmed it. This case is particular interesting, as the AAA requires surgical intervention, while patient's health status was poor. An essential issue is establishing the importance of the AAA screening, when there are no symptoms present. For now, there are not satisfactory studies to be used as a guide.

  19. Abdominal Pediatric Cancer Surveillance using Serial CT: Evaluation of Organ Absorbed Dose and Effective Dose

    PubMed Central

    Lam, Diana; Wootton-Gorges, Sandra L.; McGahan, John P.; Stern, Robin; Boone, John M.

    2012-01-01

    Computed tomography (CT) is used extensively in cancer diagnosis, staging, evaluation of response to treatment, and in active surveillance for cancer reoccurrence. A review of CT technology is provided, at a level of detail appropriate for a busy clinician to review. The basis of x-ray CT dosimetry is also discussed, and concepts of absorbed dose and effective dose are distinguished. Absorbed dose is a physical quantity (measured in milliGray) equal to the x-ray energy deposited in a mass of tissue, whereas effective dose utilizes an organ-specific weighting method which converts organ doses to effective dose measured in milliSieverts. The organ weighting values carry with them a measure of radiation risk, and so effective dose (in mSv) is not a physical dose metric but rather is one that conveys radiation risk. The use of CT in a cancer surveillance protocol was used as an example of a pediatric patient who had kidney cancer, with surgery and radiation therapy. The active use of CT for cancer surveillance along with diagnostic CT scans led to a total of 50 CT scans performed on this child in a 7 year period. It was estimated that the patient received an average organ dose of 431 mGy from these CT scans. By comparison, the radiation therapy was performed and delivered 50.4 Gy to the patient’s abdomen. Thus, the total dose from CT represented only 0.8% of the patients radiation dose. PMID:21362521

  20. Comparison of volumetric breast density estimations from mammography and thorax CT

    NASA Astrophysics Data System (ADS)

    Geeraert, N.; Klausz, R.; Cockmartin, L.; Muller, S.; Bosmans, H.; Bloch, I.

    2014-08-01

    Breast density has become an important issue in current breast cancer screening, both as a recognized risk factor for breast cancer and by decreasing screening efficiency by the masking effect. Different qualitative and quantitative methods have been proposed to evaluate area-based breast density and volumetric breast density (VBD). We propose a validation method comparing the computation of VBD obtained from digital mammographic images (VBDMX) with the computation of VBD from thorax CT images (VBDCT). We computed VBDMX by applying a conversion function to the pixel values in the mammographic images, based on models determined from images of breast equivalent material. VBDCT is computed from the average Hounsfield Unit (HU) over the manually delineated breast volume in the CT images. This average HU is then compared to the HU of adipose and fibroglandular tissues from patient images. The VBDMX method was applied to 663 mammographic patient images taken on two Siemens Inspiration (hospL) and one GE Senographe Essential (hospJ). For the comparison study, we collected images from patients who had a thorax CT and a mammography screening exam within the same year. In total, thorax CT images corresponding to 40 breasts (hospL) and 47 breasts (hospJ) were retrieved. Averaged over the 663 mammographic images the median VBDMX was 14.7% . The density distribution and the inverse correlation between VBDMX and breast thickness were found as expected. The average difference between VBDMX and VBDCT is smaller for hospJ (4%) than for hospL (10%). This study shows the possibility to compare VBDMX with the VBD from thorax CT exams, without additional examinations. In spite of the limitations caused by poorly defined breast limits, the calibration of mammographic images to local VBD provides opportunities for further quantitative evaluations.

  1. FLEX: A Modular Software Architecture for Flight License Exam

    NASA Astrophysics Data System (ADS)

    Arsan, Taner; Saka, Hamit Emre; Sahin, Ceyhun

    This paper is about the design and implementation of an examination system based on World Wide Web. It is called FLEX-Flight License Exam Software. We designed and implemented flexible and modular software architecture. The implemented system has basic specifications such as appending questions in system, building exams with these appended questions and making students to take these exams. There are three different types of users with different authorizations. These are system administrator, operators and students. System administrator operates and maintains the system, and also audits the system integrity. The system administrator can not be able to change the result of exams and can not take an exam. Operator module includes instructors. Operators have some privileges such as preparing exams, entering questions, changing the existing questions and etc. Students can log on the system and can be accessed to exams by a certain URL. The other characteristic of our system is that operators and system administrator are not able to delete questions due to the security problems. Exam questions can be inserted on their topics and lectures in the database. Thus; operators and system administrator can easily choose questions. When all these are taken into consideration, FLEX software provides opportunities to many students to take exams at the same time in safe, reliable and user friendly conditions. It is also reliable examination system for the authorized aviation administration companies. Web development platform - LAMP; Linux, Apache web server, MySQL, Object-oriented scripting Language - PHP are used for developing the system and page structures are developed by Content Management System - CMS.

  2. An efficient and robust MRI-guided radiotherapy planning approach for targeting abdominal organs and tumours in the mouse

    PubMed Central

    Bird, Luke; Tullis, Iain D. C.; Newman, Robert G.; Corroyer-Dulmont, Aurelien; Falzone, Nadia; Azad, Abul; Vallis, Katherine A.; Sansom, Owen J.; Muschel, Ruth J.; Vojnovic, Borivoj; Hill, Mark A.; Fokas, Emmanouil; Smart, Sean C.

    2017-01-01

    Introduction Preclinical CT-guided radiotherapy platforms are increasingly used but the CT images are characterized by poor soft tissue contrast. The aim of this study was to develop a robust and accurate method of MRI-guided radiotherapy (MR-IGRT) delivery to abdominal targets in the mouse. Methods A multimodality cradle was developed for providing subject immobilisation and its performance was evaluated. Whilst CT was still used for dose calculations, target identification was based on MRI. Each step of the radiotherapy planning procedure was validated initially in vitro using BANG gel dosimeters. Subsequently, MR-IGRT of normal adrenal glands with a size-matched collimated beam was performed. Additionally, the SK-N-SH neuroblastoma xenograft model and the transgenic KPC model of pancreatic ductal adenocarcinoma were used to demonstrate the applicability of our methods for the accurate delivery of radiation to CT-invisible abdominal tumours. Results The BANG gel phantoms demonstrated a targeting efficiency error of 0.56 ± 0.18 mm. The in vivo stability tests of body motion during MR-IGRT and the associated cradle transfer showed that the residual body movements are within this MR-IGRT targeting error. Accurate MR-IGRT of the normal adrenal glands with a size-matched collimated beam was confirmed by γH2AX staining. Regression in tumour volume was observed almost immediately post MR-IGRT in the neuroblastoma model, further demonstrating accuracy of x-ray delivery. Finally, MR-IGRT in the KPC model facilitated precise contouring and comparison of different treatment plans and radiotherapy dose distributions not only to the intra-abdominal tumour but also to the organs at risk. Conclusion This is, to our knowledge, the first study to demonstrate preclinical MR-IGRT in intra-abdominal organs. The proposed MR-IGRT method presents a state-of-the-art solution to enabling robust, accurate and efficient targeting of extracranial organs in the mouse and can operate with a

  3. What students learn when studying physics practice exam problems

    NASA Astrophysics Data System (ADS)

    Fakcharoenphol, Witat; Potter, Eric; Stelzer, Timothy

    2011-06-01

    We developed a web-based tool to provide students with access to old exam problems and solutions. By controlling the order in which students saw the problems, as well as their access to solutions, we obtained data about student learning by studying old exam problems. Our data suggest that in general students learn from doing old exam problems, and that having access to the problem solutions increases their learning. However, the data also suggest the depth of learning may be relatively shallow. In addition, the data show that doing old exam problems provides important formative assessment about the student’s overall preparedness for the exam and their particular areas of strength and weakness.

  4. Evaluation of Abdominal CT Image Quality Using a New Version of Vendor-Specific Model-Based Iterative Reconstruction

    PubMed Central

    Jensen, Corey T.; Telesmanich, Morgan E.; Wagner-Bartak, Nicolaus A.; Liu, Xinming; Rong, John; Szklaruk, Janio; Qayyum, Aliya; Wei, Wei; Chandler, Adam G.; Tamm, Eric P.

    2016-01-01

    Purpose To qualitatively and quantitatively compare abdominal CT images reconstructed with a new version of model-based iterative reconstruction (Veo 3.0; GE Healthcare) to those created with Veo 2.0. Materials & Methods This retrospective study was approved by our IRB and was HIPPA compliant. The raw data from 29 consecutive patients who had undergone CT abdomen scanning was used to reconstruct 4 sets of 3.75mm axial images: Veo 2.0, Veo 3.0 standard, Veo 3.0 5% resolution preference and Veo 3.0 20% resolution preference. A slice thickness optimization of 3.75 mm and texture feature was selected for Veo 3.0 reconstructions. The images were reviewed by three independent readers in a blinded, randomized fashion using a 5-point Likert scale and 5-point comparative scale. Multiple 2D circular regions of interest were defined for noise and contrast-to-noise ratio (CNR) measurements. Line profiles were drawn across the 7 lp/cm bar pattern of the CatPhan 600 phantom for spatial resolution evaluation. Results The Veo 3.0 standard image set was scored better than Veo 2.0 in terms of artifacts (mean difference 0.43, 95% CI 0.25-0.6, P<0.0001), overall image quality (mean difference 0.87, 95% CI 0.62-1.13, P<0.0001) and qualitative resolution (mean difference 0.9, 95% CI 0.69-1.1, P<0.0001). While the Veo 3.0 standard and RP05 presets were preferred across most categories, the Veo 3.0 RP20 series ranked best for bone detail. Image noise and spatial resolution increased along a spectrum with Veo 2.0 the lowest and RP20 the highest. Conclusion Veo 3.0 enhances imaging evaluation relative to Veo 2.0; readers preferred Veo 3.0 image appearance despite the associated mild increases in image noise. These results provide suggested parameters to be used clinically and as a basis for future evaluations such as focal lesion detection in the oncology setting. PMID:27529683

  5. From Exam to Education: The Math Exam/Education Resources

    ERIC Educational Resources Information Center

    Bruni, Carmen; Koch, Christina; Konrad, Bernhard; Lindstrom, Michael; Moyles, Iain; Thompson, Will

    2016-01-01

    The Math Exam/Education Resources (MER) is an open online learning resource hosted at The University of British Columbia (UBC), aimed at providing mathematics education resources for students and instructors at UBC. In this paper, there will be a discussion of the motivation for creating this resource on the MediaWiki platform, key features of the…

  6. Optimization of hybrid iterative reconstruction level in pediatric body CT.

    PubMed

    Karmazyn, Boaz; Liang, Yun; Ai, Huisi; Eckert, George J; Cohen, Mervyn D; Wanner, Matthew R; Jennings, S Gregory

    2014-02-01

    The objective of our study was to attempt to optimize the level of hybrid iterative reconstruction (HIR) in pediatric body CT. One hundred consecutive chest or abdominal CT examinations were selected. For each examination, six series were obtained: one filtered back projection (FBP) and five HIR series (iDose(4)) levels 2-6. Two pediatric radiologists, blinded to noise measurements, independently chose the optimal HIR level and then rated series quality. We measured CT number (mean in Hounsfield units) and noise (SD in Hounsfield units) changes by placing regions of interest in the liver, muscles, subcutaneous fat, and aorta. A mixed-model analysis-of-variance test was used to analyze correlation of noise reduction with the optimal HIR level compared with baseline FBP noise. One hundred CT examinations were performed of 88 patients (52 females and 36 males) with a mean age of 8.5 years (range, 19 days-18 years); 12 patients had both chest and abdominal CT studies. Radiologists agreed to within one level of HIR in 92 of 100 studies. The mean quality rating was significantly higher for HIR than FBP (3.6 vs 3.3, respectively; p < 0.01). HIR caused minimal (0-0.2%) change in CT numbers. Noise reduction varied among structures and patients. Liver noise reduction positively correlated with baseline noise when the optimal HIR level was used (p < 0.01). HIR levels were significantly correlated with body weight and effective diameter of the upper abdomen (p < 0.01). HIR, such as iDose(4), improves the quality of body CT scans of pediatric patients by decreasing noise; HIR level 3 or 4 is optimal for most studies. The optimal HIR level was less effective in reducing liver noise in children with lower baseline noise.

  7. Impact of PACS on dictation turnaround time and productivity.

    PubMed

    Lepanto, Luigi; Paré, Guy; Aubry, David; Robillard, Pierre; Lesage, Jacques

    2006-03-01

    This study was conducted to measure the impact of PACS on dictation turnaround time and productivity. The radiology information system (RIS) database was interrogated to calculate the time interval between image production and dictation for every exam performed during three 90-day periods (the 3 months preceding PACS implementation, the 3 months immediately following PACS deployment, and a 3-month period 1 year after PACS implementation). Data were obtained for three exam types: chest radiographs, abdominal CT, and spine MRI. The mean dictation turnaround times obtained during the different pre- and post-PACS periods were compared using analysis of variance (ANOVA). Productivity was also determined for each period and for each exam type, and was expressed as the number of studies interpreted per full-time equivalent (FTE) radiologist. In the immediate post-PACS period, dictation turnaround time decreased 20% (p < 0.001) for radiography, but increased 13% (ns) for CT and 28% (p < 0.001) for MRI. One year after PACS was implemented, dictation turnaround time decreased 45% (p < 0.001) for radiography and 36% (p < 0.001) for MRI. For CT, 1 year post-PACS, turnaround times returned to pre-PACS levels. Productivity in the immediate post-PACS period increased 3% and 38% for radiography and CT, respectively, whereas a 6% decrease was observed for MRI. One year after implementation, productivity increased 27%, 98%, and 19% in radiography, CT, and MRI, respectively. PACS benefits, namely, shortened dictation turnaround time and increased productivity, are evident 1 year after PACS implementation. In the immediate post-PACS period, results vary with the different imaging modalities.

  8. An unusual cause of acute abdominal pain in dengue fever.

    PubMed

    Waseem, Tariq; Latif, Hina; Shabbir, Bilquis

    2014-07-01

    Dengue fever is an acute febrile viral disease caused by the bite of Aedes aegypti mosquito. It is a major health problem especially in tropical and subtropical areas including South East Asia and Pakistan. In the past few years, dengue fever has been endemic in Northern Punjab. Physicians managing dengue fever come across varied and uncommon complications of dengue fever. We report a case of dengue fever that developed severe right upper quadrant abdominal pain and induration after extreme retching and vomiting for 2 days. A rectus sheath hematoma was confirmed on noncontrast computed tomography (CT). Rectus sheath hematoma as a complication of dengue fever has rarely been reported before and never from this part of the world. Rectus sheath hematoma is an uncommon and often clinically misdiagnosed cause of abdominal pain. It is the result of bleeding into the rectus sheath from damage to the superior or inferior epigastric artery or their branches or from a direct tear of the rectus muscle. It can mimic almost any abdominal condition (See Fig.) (See Table).

  9. Nosocomial rapidly growing mycobacterial infections following laparoscopic surgery: CT imaging findings.

    PubMed

    Volpato, Richard; de Castro, Claudio Campi; Hadad, David Jamil; da Silva Souza Ribeiro, Flavya; Filho, Ezequiel Leal; Marcal, Leonardo P

    2015-09-01

    To identify the distribution and frequency of computed tomography (CT) findings in patients with nosocomial rapidly growing mycobacterial (RGM) infection after laparoscopic surgery. A descriptive retrospective study in patients with RGM infection after laparoscopic surgery who underwent CT imaging prior to initiation of therapy. The images were analyzed by two radiologists in consensus, who evaluated the skin/subcutaneous tissues, the abdominal wall, and intraperitoneal region separately. The patterns of involvement were tabulated as: densification, collections, nodules (≥1.0 cm), small nodules (<1.0 cm), pseudocavitated nodules, and small pseudocavitated nodules. Twenty-six patients met the established criteria. The subcutaneous findings were: densification (88.5%), small nodules (61.5%), small pseudocavitated nodules (23.1 %), nodules (38.5%), pseudocavitated nodules (15.4%), and collections (26.9%). The findings in the abdominal wall were: densification (61.5%), pseudocavitated nodules (3.8%), and collections (15.4%). The intraperitoneal findings were: densification (46.1%), small nodules (42.3%), nodules (15.4%), and collections (11.5%). Subcutaneous CT findings in descending order of frequency were: densification, small nodules, nodules, small pseudocavitated nodules, pseudocavitated nodules, and collections. The musculo-fascial plane CT findings were: densification, collections, and pseudocavitated nodules. The intraperitoneal CT findings were: densification, small nodules, nodules, and collections. • Rapidly growing mycobacterial infection may occur following laparoscopy. • Post-laparoscopy mycobacterial infection CT findings are densification, collection, and nodules. • Rapidly growing mycobacterial infection following laparoscopy may involve the peritoneal cavity. • Post-laparoscopy rapidly growing mycobacterial intraperitoneal infection is not associated with ascites or lymphadenopathy.

  10. Tailoring the Preparticipation Exam to Female Athletes.

    ERIC Educational Resources Information Center

    Johnson, Mimi D.

    1992-01-01

    Discusses the basics of the preparticipation exam, focusing on aspects specific to females, such as menstrual dysfunction, disordered eating, and orthopedic problems such as scoliosis and patellofemoral pain. Health history questionnaire and other parts of the exam are included in six tables. (SM)

  11. Comparison of diagnostic performance between single- and multiphasic contrast-enhanced abdominopelvic computed tomography in patients admitted to the emergency department with abdominal pain: potential radiation dose reduction.

    PubMed

    Hwang, Shin Hye; You, Je Sung; Song, Mi Kyong; Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun

    2015-04-01

    To evaluate feasibility of radiation dose reduction by optimal phase selection of computed tomography (CT) in patients who visited the emergency department (ED) for abdominal pain. We included 253 patients who visited the ED for abdominal pain. They underwent multiphasic CT including precontrast, late arterial phase (LAP), and hepatic venous phase (HVP). Three image sets (HVP, precontrast + HVP, and precontrast + LAP + HVP) were reviewed. Two reviewers determined the most appropriate diagnosis with five-point confidence scale. Diagnostic performances were compared among image sets by weighted-least-squares method or DeLong's method. Linear mixed model was used to assess changes of diagnostic confidence and radiation dose. There was no difference in diagnostic performance among three image sets, although diagnostic confidence level was significantly improved after review of triphasic images compared with both HVP images only or HVP with precontrast images (confidence scale, 4.64 ± 0.05, 4.66 ± 0.05, and 4.76 ± 0.04 in the order of the sets; overall P = 0.0008). Similar trends were observed in the subgroup analysis for diagnosis of pelvic inflammatory disease and cholecystitis. There is no difference between HVP-CT alone and multiphasic CT for the diagnosis of causes of abdominal pain in patients admitted to the ED without prior chronic disease or neoplasia. • There was no difference in diagnostic performance of HVP CT and multiphasic CT. • The diagnostic confidence level was improved after review of the LAP images. • HVP CT can achieve diagnostic performance similar to that of multiphasic CT, while minimizing radiation.

  12. The evaluation of eye pain with a normal ocular exam.

    PubMed

    Lee, Andrew G; Brazis, Paul W

    2003-12-01

    Eye pain with or without associated head or face pain is a common complaint to the ophthalmologist. The ocular exam may reveal the etiology (e.g., corneal disease, angle closure glaucoma) but typically the exam is normal. This paper reviews the evaluation and management of eye pain with a "normal" ocular exam, including: 1) subtle findings on ocular exam; 2) transient findings on exam, and 3) no abnormal ocular findings. Ophthalmologists should be aware of the various etiologies for eye pain and the specific and distinctive features that make the diagnosis.

  13. A reappraisal of adult abdominal surface anatomy.

    PubMed

    Mirjalili, S Ali; McFadden, Sara L; Buckenham, Tim; Stringer, Mark D

    2012-10-01

    Descriptions of clinically important surface landmarks often vary between and within contemporary anatomical texts. The aim of this study was to investigate the surface anatomy of major abdominal vessels, kidneys, spleen, gastroesophageal junction, and duodenojejunal flexure in living adults using computed tomography (CT). After excluding patients with distorting space-occupying lesions, scoliosis, abnormal lordosis, and obvious visceromegaly, 108 abdominal CT scans of supine adults (mean age 60 years, range 18-97 years; 64 female) at end tidal inspiration were available for analysis by dual consensus reporting. Intra-observer agreement was assessed by repeat blind assessment of a random sample of scans. The vertebral level of the aortic bifurcation and almost all of its major branches, and the origin of the inferior vena cava were consistent with current descriptions. Important differences from contemporary descriptions of surface anatomy were as follows: the renal arteries were most commonly at the L1 vertebral level (left 55%, right 43%); the midpoint of the renal hila was most frequently at L2 (left 68%, right 40%); the 11th rib was a posterior relation of the left kidney in only 28% of scans; and the spleen was most frequently located between the 10th and 12th ribs (48%) with its long axis in line with the 11th rib (55%). Although the majority of vascular surface landmarks are consistent with standard descriptions, the surface anatomy of the kidneys, renal arteries, and spleen needs to be revised in accordance with observations using modern imaging techniques in vivo. Copyright © 2012 Wiley Periodicals, Inc.

  14. Sci—Thur PM: Imaging — 06: Canada's National Computed Tomography (CT) Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wardlaw, GM; Martel, N; Blackler, W

    2014-08-15

    The value of computed tomography (CT) in medical imaging is reflected in its' increased use and availability since the early 1990's; however, given CT's relatively larger exposures (vs. planar x-ray) greater care must be taken to ensure that CT procedures are optimised in terms of providing the smallest dose possible while maintaining sufficient diagnostic image quality. The development of CT Diagnostic Reference Levels (DRLs) supports this process. DRLs have been suggested/supported by international/national bodies since the early 1990's and widely adopted elsewhere, but not on a national basis in Canada. Essentially, CT DRLs provide guidance on what is considered goodmore » practice for common CT exams, but require a representative sample of CT examination data to make any recommendations. Canada's National CT Survey project, in collaboration with provincial/territorial authorities, has collected a large national sample of CT practice data for 7 common examinations (with associated clinical indications) of both adult and pediatric patients. Following completion of data entry into a common database, a survey summary report and recommendations will be made on CT DRLs from this data. It is hoped that these can then be used by local regions to promote CT practice optimisation and support any dose reduction initiatives.« less

  15. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT

    NASA Astrophysics Data System (ADS)

    Angel, Erin; Yaghmai, Nazanin; Matilda Jude, Cecilia; DeMarco, John J.; Cagnon, Christopher H.; Goldin, Jonathan G.; Primak, Andrew N.; Stevens, Donna M.; Cody, Dianna D.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-02-01

    Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were

  16. Investigating the Effects of Exam Length on Performance and Cognitive Fatigue

    PubMed Central

    Jensen, Jamie L.; Berry, Dane A.; Kummer, Tyler A.

    2013-01-01

    This study examined the effects of exam length on student performance and cognitive fatigue in an undergraduate biology classroom. Exams tested higher order thinking skills. To test our hypothesis, we administered standard- and extended-length high-level exams to two populations of non-majors biology students. We gathered exam performance data between conditions as well as performance on the first and second half of exams within conditions. We showed that lengthier exams led to better performance on assessment items shared between conditions, possibly lending support to the spreading activation theory. It also led to greater performance on the final exam, lending support to the testing effect in creative problem solving. Lengthier exams did not result in lower performance due to fatiguing conditions, although students perceived subjective fatigue. Implications of these findings are discussed with respect to assessment practices. PMID:23950918

  17. Serial volumetric registration of pulmonary CT studies

    NASA Astrophysics Data System (ADS)

    Silva, José Silvestre; Silva, Augusto; Sousa Santos, Beatriz

    2008-03-01

    Detailed morphological analysis of pulmonary structures and tissue, provided by modern CT scanners, is of utmost importance as in the case of oncological applications both for diagnosis, treatment, and follow-up. In this case, a patient may go through several tomographic studies throughout a period of time originating volumetric sets of image data that must be appropriately registered in order to track suspicious radiological findings. The structures or regions of interest may change their position or shape in CT exams acquired at different moments, due to postural, physiologic or pathologic changes, so, the exams should be registered before any follow-up information can be extracted. Postural mismatching throughout time is practically impossible to avoid being particularly evident when imaging is performed at the limiting spatial resolution. In this paper, we propose a method for intra-patient registration of pulmonary CT studies, to assist in the management of the oncological pathology. Our method takes advantage of prior segmentation work. In the first step, the pulmonary segmentation is performed where trachea and main bronchi are identified. Then, the registration method proceeds with a longitudinal alignment based on morphological features of the lungs, such as the position of the carina, the pulmonary areas, the centers of mass and the pulmonary trans-axial principal axis. The final step corresponds to the trans-axial registration of the corresponding pulmonary masked regions. This is accomplished by a pairwise sectional registration process driven by an iterative search of the affine transformation parameters leading to optimal similarity metrics. Results with several cases of intra-patient, intra-modality registration, up to 7 time points, show that this method provides accurate registration which is needed for quantitative tracking of lesions and the development of image fusion strategies that may effectively assist the follow-up process.

  18. Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative.

    PubMed

    Dykes, Thomas M; Bhargavan-Chatfield, Mythreyi; Dyer, Raymond B

    2015-02-01

    Establish 3 performance benchmarks for intravenous contrast extravasation during CT examinations: extravasation frequency, distribution of extravasation volumes, and severity of injury. Evaluate the effectiveness of implementing practice quality improvement (PQI) methodology in improving performance for these 3 benchmarks. The Society of Abdominal Radiology and ACR developed a registry collecting data for contrast extravasation events. The project includes a PQI initiative allowing for process improvement. As of December 2013, a total of 58 radiology practices have participated in this project, and 32 practices have completed the 2-cycle PQI. There were a total of 454,497 contrast-enhanced CT exams and 1,085 extravasation events. The average extravasation rate is 0.24%. The median extravasation rate is 0.21%. Most extravasations (82.9%) were between 10 mL and 99 mL. The majority of injuries, 94.6%, are mild in severity, with 4.7% having moderate and 0.8% having severe injuries. Data from practices that completed the PQI process showed a change in the average extravasation rate from 0.28% in the first 6 months to 0.23% in the second 6 months, and the median extravasation rate dropped from 0.25% to 0.16%, neither statistically significant. The distribution of extravasation volumes and the severity of injury did not change between the first and second measurement periods. National performance benchmarks for contrast extravasation rate, distribution of volumes of extravasate, and distribution of severity of injury are established through this multi-institutional practice registry. The application of PQI failed to have a statistically significant positive impact on any of the 3 benchmarks. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. Cecocentral scotoma as the initial manifestation of subacute bacterial endocarditis

    PubMed Central

    Strauss, Danielle Savitsky; Baharestani, Samuel; Nemiroff, Julia; Amesur, Kiran; Howard, David

    2011-01-01

    Introduction: We report a case of a 67-year-old male who presented with a cecocentral scotoma caused by a septic embolus from subacute bacterial endocarditis (SBE). Methods: A 67-year-old man presented with sudden, painless decreased vision in the left eye. A dilated fundoscopic exam, Humphrey visual field test, transthoracic echocardiogram, abdominal computed tomography (CT), and blood cultures were all performed. Results: A dilated fundoscopic exam revealed temporal segmental optic disc pallor on the left, and Humphrey visual field testing demonstrated a dense left cecocentral scotoma. When the patient developed fever (103. 9°F) and palpitations, transthoracic echocardiogram revealed valvular vegetations, and contrast CT of the abdomen revealed an abscess in the dome of the liver likely due to an infectious thrombus. Blood cultures grew viridians group streptococci in three separate peripheral collections. Conclusion: This case illustrates that a sudden cecocentral scotoma may be the initial manifestation of SBE. PMID:21468335

  20. Evaluation of organ doses in CT examinations with an infant anthropomorphic phantom.

    PubMed

    Fujii, K; Akahane, K; Miyazaki, O; Horiuchi, T; Shimada, A; Nagmatsu, H; Yamauchi, M; Yamauchi-Kawaura, C; Kawasaki, T

    2011-09-01

    The aim of this study is to evaluate organ doses in infant CT examinations with multi-detector row CT scanners. Radiation doses were measured with radiophotoluminescence glass dosemeters set in various organ positions within a 1-y-old child anthropomorphic phantom and organ doses were evaluated from the measurement values. Doses for tissues or organs within the scan range were 28-36 mGy in an infant head CT, 3-11 mGy in a chest CT, 5-11 mGy in an abdominal-pelvic CT and 2-14 mGy in a cardiac CT. The doses varied by the differences in the types of CT scanners and scan parameters used at each medical facility. Compared with those for children of various ages, the doses in an infant CT protocol were found to be similar to or slightly smaller than those in a paediatric CT for 5- or 6-y-old children.

  1. CT manifestations of peritoneal carcinomatosis.

    PubMed

    Walkey, M M; Friedman, A C; Sohotra, P; Radecki, P D

    1988-05-01

    Seventy-three abdominopelvic contrast-enhanced CT scans obtained in 60 patients with peritoneal tumor spread were reviewed retrospectively to determine the CT signs of peritoneal malignancy. Ascites was present in 54 studies (74%) and was the most common CT finding. Loculation of the fluid occurred in 25 (46%) of these. In nine (17%) of the 54, a new finding, absence of cul-de-sac fluid in the presence of generalized ascites, was noted. Parietal peritoneal thickening with contrast enhancement of the peritoneum, making the peritoneum visible as a thin line along the abdominal wall, was present in 45 (62%) of studies. This is believed to represent confluent peritoneal metastases. Small-bowel involvement was present in half of the cases (wall thickening and irregularity with or without obstruction). Tumor involvement of the omentum was visible as soft-tissue permeation of fat, enhancing nodules, and/or an omental cake. Of the 26 patients without a previously known malignancy, identification of the primary tumor in addition to peritoneal carcinomatosis was possible in 13 (50%). Appreciation of the spectrum of CT findings in peritoneal carcinomatosis is essential for accurate evaluation of scans in patients with abdominopelvic malignancies.

  2. Towards remote assessment and screening of acute abdominal pain using only a smartphone with native accelerometers.

    PubMed

    Myers, David R; Weiss, Alexander; Rollins, Margo R; Lam, Wilbur A

    2017-10-06

    Smartphone-based telehealth holds the promise of shifting healthcare from the clinic to the home, but the inability for clinicians to conduct remote palpation, or touching, a key component of the physical exam, remains a major limitation. This is exemplified in the assessment of acute abdominal pain, in which a physician's palpation determines if a patient's pain is life-threatening requiring emergency intervention/surgery or due to some less-urgent cause. In a step towards virtual physical examinations, we developed and report for the first time a "touch-capable" mHealth technology that enables a patient's own hands to serve as remote surrogates for the physician's in the screening of acute abdominal pain. Leveraging only a smartphone with its native accelerometers, our system guides a patient through an exact probing motion that precisely matches the palpation motion set by the physician. An integrated feedback algorithm, with 95% sensitivity and specificity, enabled 81% of tested patients to match a physician abdominal palpation curve with <20% error after 6 attempts. Overall, this work addresses a key issue in telehealth that will vastly improve its capabilities and adoption worldwide.

  3. Tissue Doppler Imaging in the evaluation of abdominal aortic pulsatility: a useful tool for the neonatologist.

    PubMed

    Valerio, Enrico; Grison, Alessandra; Capretta, Anna; Golin, Rosanna; Ferrarese, Paola; Bellettato, Massimo

    2017-03-01

    Sonographic cardiac evaluation of newborns with suspected aortic coarctation (AoC) should tend to demonstrate a good phasic and pulsatile flow and the absence of pressure gradient along a normally conformed aortic arch from the modified left parasternal and suprasternal echocardiographic views; these findings, however, may not necessarily rule out a more distal coarctation in the descending aorta. For this reason, the sonographic exam of newborns with suspected AoC should always include a Doppler evaluation of abdominal aortic blood flow from the subcostal view. Occasionally, however, a clearly pulsatile Doppler flow trace in abdominal aorta may be difficult to obtain due to the bad insonation angle existing between the probe and the vessel. In such suboptimal ultrasonic alignment situation, the use of Tissue Doppler Imaging instead of classic Doppler flow imaging may reveal a preserved aortic pulsatility by sampling the aortic wall motion induced by normal flow. We propose to take advantage of the TDI pattern as a surrogate of a normal pulsatile Doppler flow trace in abdominal aorta when the latter is difficult to obtain due to malalignment with the insonated vessel.

  4. 4D CT sorting based on patient internal anatomy

    NASA Astrophysics Data System (ADS)

    Li, Ruijiang; Lewis, John H.; Cerviño, Laura I.; Jiang, Steve B.

    2009-08-01

    Respiratory motion during free-breathing computed tomography (CT) scan may cause significant errors in target definition for tumors in the thorax and upper abdomen. A four-dimensional (4D) CT technique has been widely used for treatment simulation of thoracic and abdominal cancer radiotherapy. The current 4D CT techniques require retrospective sorting of the reconstructed CT slices oversampled at the same couch position. Most sorting methods depend on external surrogates of respiratory motion recorded by extra instruments. However, respiratory signals obtained from these external surrogates may not always accurately represent the internal target motion, especially when irregular breathing patterns occur. We have proposed a new sorting method based on multiple internal anatomical features for multi-slice CT scan acquired in the cine mode. Four features are analyzed in this study, including the air content, lung area, lung density and body area. We use a measure called spatial coherence to select the optimal internal feature at each couch position and to generate the respiratory signals for 4D CT sorting. The proposed method has been evaluated for ten cancer patients (eight with thoracic cancer and two with abdominal cancer). For nine patients, the respiratory signals generated from the combined internal features are well correlated to those from external surrogates recorded by the real-time position management (RPM) system (average correlation: 0.95 ± 0.02), which is better than any individual internal measures at 95% confidence level. For these nine patients, the 4D CT images sorted by the combined internal features are almost identical to those sorted by the RPM signal. For one patient with an irregular breathing pattern, the respiratory signals given by the combined internal features do not correlate well with those from RPM (correlation: 0.68 ± 0.42). In this case, the 4D CT image sorted by our method presents fewer artifacts than that from the RPM signal. Our

  5. Incidental Detection of Urinary Leakage on FDG PET/CT Imaging for Staging of Gastric Cancer.

    PubMed

    Kim, Dae-Weung; Kim, Myoung Hyoun; Kim, Chang Guhn

    2016-03-01

    A 71-year-old woman presented to the emergency department with right flank pain and dysuria. An abdominal CT scan detected a gastric malignancy and hydronephrosis with urinary leakage of the right kidney. Percutaneous nephrostomy was performed on the right kidney. F-FDG PET/CT for staging the gastric malignancy revealed additional urinary leakage of the contralateral kidney. The interest in this case is the incidental detection of unexpected urinary leakage during an oncologic assessment with FDG PET/CT.

  6. Pelvic bone asymmetry in 323 study participants receiving abdominal CT scans.

    PubMed

    Badii, Maziar; Shin, Sonya; Torreggiani, William C; Jankovic, Bojana; Gustafson, Paul; Munk, Peter L; Esdaile, John M

    2003-06-15

    Retrospective review of all CT scans of pelvis and abdomen performed at our institution in October and November 2000. To determine the prevalence and extent of radiographic pelvic asymmetry in a population of patients not preselected for having low back pain. Pelvic asymmetry refers to asymmetric positioning of landmarks on the two sides of the pelvis and may have a structural or functional etiology. Pelvic asymmetry can be associated with the presence of true leg length discrepancy, lead to false diagnosis or inaccurate measurement of leg length discrepancy, or itself be independently associated with back pain. Although the prevalence of pelvic asymmetry has been reported in patients with back pain to be 24-91%, its prevalence in the general population is not known. A total of 323 consecutive CT scans of the pelvis/abdomen were assessed for pelvic asymmetry by one of three examiners. Pelvic asymmetry was defined as an unequal distance from the iliac crests to the acetabuli bilaterally, measured on the anteroposterior scout view of the CT scan. Measurements made on 30 randomly selected scans by the three examiners were used to assess interrater reliability of the measurement method. Pelvic asymmetry ranged in magnitude from -11 mm to 7 mm [right pelvis (mm) - left pelvis (mm)]. Pelvic asymmetry was >5 mm in 17 of 323 (5.3%) and >10 mm in 2 of 323 (0.6%) of the subjects; 172 of 323 (53.3%) had a smaller right hemipelvis (mean asymmetry = -3.0 mm). A total of 95 of 323 (29.4%) had a smaller left hemipelvis (mean asymmetry = 2.1 mm). The intraclass correlation coefficient [ICC(2,1)] between the three observers was high (0.91). Pelvic asymmetry of >5 mm was uncommon, with a prevalence of approximately 5% in the population studied. CT scanography was found to be a practical and reliable method for the assessment of suspected pelvic asymmetry.

  7. The role of CT-guided percutaneous drainage of loculated air collections: an institutional experience.

    PubMed

    Patel, Bhavik N; Morgan, Madeline; Tyler, Douglas; Paulson, Erik; Jaffe, Tracy A

    2015-10-01

    The purpose of this study is to describe our experience with the role of CT-guided percutaneous drainage of loculated intra-abdominal collections consisting entirely of gas. An IRB-approved retrospective study analyzing patients with air-only intra-abdominal collections over an 8-year period was undertaken. Seven patients referred for percutaneous drainage were included. Size of collections, subsequent development of fluid, and microbiological yield were determined. Clinical outcome was also analyzed. Out of 2835 patients referred for percutaneous drainage between 2004 and 2012, seven patients (5M, 2F; average age 63, range 54-85) met criteria for inclusion with CT showing air-only collections. Percutaneous drain placement (five 8 Fr, one 10 Fr, and one 12 Fr) using Seldinger technique was performed. Four patients (57%) had recently undergone surgery (2 Whipple, 1 colectomy, 1 hepatic resection) while two (29%) had a remote surgery (1 abdominoperineal resection, 1 sigmoidectomy). Despite the lack of detectable fluid on the original CT, 6 patients (86%) had air and fluid aspirated at drainage, 5 (83%) of the aspirates developed positive microbacterial cultures. Four patients (57%) presented with fever at the time of the initial scan, all of whom had positive cultures from aspirated fluid. Four patients (57%) had leukocytosis, all of whom had positive cultures from aspirated fluid. Although relatively rare in occurrence, patients with air-only intra-abdominal collections with signs of infection should be considered for percutaneous management similar to that of conventional infected fluid collections. Although fluid is not visible on CT, these collections can produce fluid that contains organisms.

  8. Developing On-line Exams.

    ERIC Educational Resources Information Center

    Hartsell, Taralynn S.; Yuen, Steve Chi-Yin

    2003-01-01

    Discusses advantages and limitations of online exams, describes available software tools for creating computer-based tests (CGI, JavaScript, commercial programs, course authoring tools), and offers suggestions for implementation. (JOW)

  9. [Abdominal trauma].

    PubMed

    Sido, B; Grenacher, L; Friess, H; Büchler, M W

    2005-09-01

    Blunt abdominal trauma is much more frequent than penetrating abdominal trauma in Europe. As a consequence of improved quality of computed tomography, even complex liver injuries are increasingly being treated conservatively. However, missed hollow viscus injuries still remain a problem, as they considerably increase mortality in multiply injured patients. Laparoscopy decreases the rate of unnecessary laparotomies in perforating abdominal trauma and helps to diagnose injuries of solid organs and the diaphragm. However, the sensitivity in detecting hollow viscus injuries is low and the role of laparoscopy in blunt abdominal injury has not been defined. If intra-abdominal bleeding is difficult to control in hemodynamically unstable patients, damage control surgery with packing of the liver, total splenectomy, and provisional closure of hollow viscus injuries is of importance. Definitive surgical treatment follows hemodynamic stabilization and restoration of hemostasis. Injuries of the duodenum and pancreas after blunt abdominal trauma are often associated with other intra-abdominal injuries and the treatment depends on their location and severity.

  10. Will students pass a competitive exam that they failed in their dreams?

    PubMed

    Arnulf, Isabelle; Grosliere, Laure; Le Corvec, Thibault; Golmard, Jean-Louis; Lascols, Olivier; Duguet, Alexandre

    2014-10-01

    We tested whether dreams can anticipate a stressful exam and how failure/success in dreams affect next-day performance. We collected information on students' dreams during the night preceding the medical school entrance exam. Demographic, academic, sleep and dream characteristics were compared to the students' grades on the exam. Of the 719 respondents to the questionnaire (of 2324 total students), 60.4% dreamt of the exam during the night preceding it. Problems with the exam appeared in 78% of dreams and primarily involved being late and forgetting answers. Reporting a dream about the exam on the pre-exam night was associated with better performance on the exam (p=.01). The frequency of dreams concerning the exam during the first term predicted proportionally higher performance on the exam (R=0.1, p=.01). These results suggest that the negative anticipation of a stressful event in dreams is common and that this episodic simulation provides a cognitive gain. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Marshburn performs Tonometry Eye Exam on Hadfield

    NASA Image and Video Library

    2013-01-21

    ISS034-E-035949 (21 Jan. 2013) --- NASA astronaut Tom Marshburn (right), Expedition 34 flight engineer, performs a Tonometry eye exam on Canadian Space Agency astronaut Chris Hadfield, flight engineer, in the Columbus laboratory of the International Space Station. The purpose of this exam is to measure intraocular eye pressure.

  12. Chronic abdominal wall pain misdiagnosed as functional abdominal pain.

    PubMed

    van Assen, Tijmen; de Jager-Kievit, Jenneke W A J; Scheltinga, Marc R; Roumen, Rudi M H

    2013-01-01

    The abdominal wall is often neglected as a cause of chronic abdominal pain. The aim of this study was to identify chronic abdominal wall pain syndromes, such as anterior cutaneous nerve entrapment syndrome (ACNES), in a patient population diagnosed with functional abdominal pain, including irritable bowel syndrome, using a validated 18-item questionnaire as an identification tool. In this cross-sectional analysis, 4 Dutch primary care practices employing physicians who were unaware of the existence of ACNES were selected. A total of 535 patients ≥18 years old who were registered with a functional abdominal pain diagnosis were approached when they were symptomatic to complete the questionnaire (maximum 18 points). Responders who scored at least the 10-point cutoff value (sensitivity, 0.94; specificity, 0.92) underwent a diagnostic evaluation to establish their final diagnosis. The main outcome was the presence and prevalence of ACNES in a group of symptomatic patients diagnosed with functional abdominal pain. Of 535 patients, 304 (57%) responded; 167 subjects (31%) recently reporting symptoms completed the questionnaire. Of 23 patients who scored above the 10-point cutoff value, 18 were available for a diagnostic evaluation. In half of these subjects (n = 9) functional abdominal pain (including IBS) was confirmed. However, the other 9 patients were suffering from abdominal wall pain syndrome, 6 of whom were diagnosed with ACNES (3.6% prevalence rate of symptomatic subjects; 95% confidence interval, 1.7-7.6), whereas the remaining 3 harbored a painful lipoma, an abdominal herniation, and a painful scar. A clinically relevant portion of patients previously diagnosed with functional abdominal pain syndrome in a primary care environment suffers from an abdominal wall pain syndrome such as ACNES.

  13. Class A and Class B UST Operator Exams

    EPA Pesticide Factsheets

    Learn about exams developed by EPA to help underground storage tank system owners and operators in Indian country meet the 2015 federal UST regulation requirement that designated operators demonstrate knowledge and pass an exam.

  14. Is prophylactic embolization of the hepatic falciform artery needed before radioembolization in patients with 99mTc-MAA accumulation in the anterior abdominal wall?

    PubMed

    Ahmadzadehfar, Hojjat; Möhlenbruch, Markus; Sabet, Amir; Meyer, Carsten; Muckle, Marianne; Haslerud, Torjan; Wilhelm, Kai; Schild, Hans Heinz; Biersack, Hans Jürgen; Ezziddin, Samer

    2011-08-01

    While influx of chemoembolic agents into the hepatic falciform artery (HFA) from the hepatic artery can cause supraumbilical skin rash, epigastric pain and even skin necrosis, the significance of a patent HFA in patients undergoing radioembolization is not completely clear. Furthermore, the presence of tracer in the anterior abdominal wall seen in (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) images, which is generally performed prior to radioembolization, has been described as a sign of a patent HFA. The aim of this retrospective study was to evaluate the incidence and consequences of (99m)Tc-MAA accumulation in the anterior abdominal wall, indicating a patent HFA, in patients undergoing radioembolization of liver tumours. A total of 224 diagnostic hepatic angiograms combined with (99m)Tc-MAA SPECT/CT were acquired in 192 patients with different types of cancer, of whom 142 were treated with a total of 214 radioembolization procedures. All patients received a whole-body scan, and planar and SPECT/CT scans of the abdomen. Only patients with extrahepatic (99m)Tc-MAA accumulation in the anterior abdominal wall were included in this study. Posttreatment bremsstrahlung SPECT/CT and follow-up results for at least 3 months served as reference standards. Tracer accumulation in the anterior abdominal wall was present in pretreatment (99m)Tc-MAA SPECT/CT images of 18 patients (9.3%). The HFA was found and embolized by radiologists before treatment in one patient. In the remaining patients radioembolization was performed without any modification in the treatment plan despite the previously mentioned extrahepatic accumulation. Only one patient experienced abdominal muscle pain above the navel, which started 24 h after treatment and lasted for 48 h without any skin changes. The remaining patients did not experience any relevant side effects during the follow-up period. Side effects after radioembolization in patients with tracer accumulation in the anterior abdominal

  15. Neck circumference as a measure of neck fat and abdominal visceral fat in Chinese adults

    PubMed Central

    2014-01-01

    Background Visceral adipose tissue (VAT) is a unique pathogenic fatty deposit, in that it is closely correlated with risk of cardiovascular diseases. The present study is to investigate the usefulness of neck circumference (NC) to indicate VAT. Methods Participants aged 35 to 75 years who had taken abdomen and neck computer tomography (CT) examination were included in this study. Neck adipose tissue, abdominal VAT and subcutaneous adipose tissue (SAT) areas, as well as sagittal abdominal diameter (SAD) were measured by CT. Body anthropometrics and metabolic parameters including blood glucose, lipid profiles and blood pressure were also measured. Results A lower abdomen CT examination was carried out on a total of 177 patients (87 male and 90 female) with a mean age of 59 years. Of the 177 participants, 15 men and 15 women also took a neck CT examination. With a comparable age and BMI, neck adipose area was correlated with abdominal VAT area significantly in men (r = 0.57, p = 0.028) and women (r = 0.53, p = 0.041). NC is positively correlated with VAT both in men (r = 0.49, p < 0.001) and women (r = 0.25, p = 0.012). Meanwhile, SAD is the best predictor for visceral fat both in men (r = 0.83, p < 0.001) and women (r = 0.73, p < 0.001). Body mass index (BMI), waist circumference (WC), and waist to height ratio (WHtR) correlated significantly with VAT both in men and women (r = 0.68, 0.42, 0.46 in men and 0.50, 0.23, 0.39 in women, p < 0.001), while waist hip ratio (WHR) displayed the weakest least correlation in men (r = 0.32, p = 0.001) and no correlation in women (r = 0.08, p = 0.442). Additionally, BMI was more strongly correlated with VAT than NC in both sexes (both p < 0.01). Conclusion Significant correlation between NC and VAT was present in Chinese men and women, which may be accounted by the fact that neck fat area is significantly correlated with abdominal VAT. Meanwhile, SAD is

  16. Exam Question Sequencing Effects and Context Cues

    ERIC Educational Resources Information Center

    Davis, Doris Bitler

    2017-01-01

    Providing two or more versions of multiple-choice exams has long been a popular strategy for reducing the opportunity for students to engage in academic dishonesty. While the results of studies comparing exam scores under different question-order conditions have been inconclusive, the potential importance of contextual cues to aid student recall…

  17. Performing pediatric eye exams in primary care.

    PubMed

    Martin, Elaine F

    2017-08-17

    Early vision care is critical for all children. If undetected, eye disorders such as amblyopia and strabismus may result in permanent vision loss. Vision exams should include a careful history and physical including fix and follow, red reflex, and cover/uncover testing. Photo screening and visual acuity exams should be administered whenever possible.

  18. The use of ultrasound in the diagnosis of abdominal wall hernias.

    PubMed

    Young, J; Gilbert, A I; Graham, M F

    2007-08-01

    The diagnosis of abdominal wall hernias is not always straightforward and may require additional investigative modalities. Real-time ultrasound is accurate, non-invasive, relatively inexpensive, and readily available. The value of ultrasound as an adjunctive tool in the diagnosis of abdominal wall hernias in both pre-operative and post-operative patients was studied. Retrospective analysis of 200 patients treated at the Hernia Institute of Florida was carried out. In these cases, ultrasound had been used to assist with case management. Patients without previous hernia surgery and those with early and late post-herniorrhaphy complaints were studied. Patients with obvious hernias were excluded. Indications for ultrasound examination included patients with abdominal pain without a palpable hernia, a palpable mass of questionable etiology, and patients with inordinate pain or excessive swelling during the early post-operative period. Patients were treated with surgery or conservative therapy depending on the results of the physical examination and ultrasound studies. Cases in which the ultrasound findings influenced the decision-making process by confirming clinical findings or altering the diagnosis and changing the treatment plan are discussed. Of the 200 patients, 144 complained of pain alone and on physical exam no hernia or mass was palpable. Of these 144 patients with pain alone, 21 had a hernia identified on the US examination and were referred for surgery. The 108 that had a negative ultrasound were treated conservatively with rest, heat, and anti-inflammatory drugs, most often with excellent results. Of the 56 remaining patients who had a mass, with or without pain, 22 had hernias identified by means of ultrasound examination. In the other 34, the etiology of the mass was not a hernia. Abdominal wall ultrasound is a valuable tool in the scheme of management of patients in whom the diagnosis of abdominal wall hernia is unclear. Therapeutic decisions can be

  19. Investigation into the need for ingesting foreign imaging exams into local systems and evaluation of the design challenges of Foreign Exam Management (FEM)

    NASA Astrophysics Data System (ADS)

    Milovanovic, Lazar; Agrawal, Arun; Bak, Peter; Bender, Duane; Koff, David

    2015-03-01

    The deployment of regional and national Electronic Health Record solutions has been a focus of many countries throughout the past decade. Most of these deployments have taken the approach of "sharing" imaging exams via portals and web-based viewers. The motivation of portal/web-based access is driven by a) the perception that review of imaging exams via portal methods is satisfactory to all users and b) the perceived complexity of ingesting foreign exams into local systems. This research project set out to objectively evaluate who really needs foreign exams within their local systems, what those systems might be and how often this is required. Working on the belief that Foreign Exam Management (FEM) is required to support clinical workflow, the project implemented a FEM capability within an XDSI. b domain to identify the design challenges and nuances associated with FEM.

  20. Short- and long-term effects of clinical audits on compliance with procedures in CT scanning.

    PubMed

    Oliveri, Antonio; Howarth, Nigel; Gevenois, Pierre Alain; Tack, Denis

    2016-08-01

    To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific "paediatric brain CT" procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from <0.001 to 0.031) in both hospitals and remained unchanged during the third audit (P ranging from 0.114 to 0.999). Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. • Compliance with CT procedures is operator-dependent and not perfect. • Compliance differs between procedures and hospitals, even within a unified department. • Compliance is improved through audits followed by communication to the stakeholders. • This improvement is sustainable over a one-year period.

  1. Remote CT reading using an ultramobile PC and web-based remote viewing over a wireless network.

    PubMed

    Choi, Hyuk Joong; Lee, Jeong Hun; Kang, Bo Seung

    2012-01-01

    We developed a new type of mobile teleradiology system using an ultramobile PC (UMPC) for web-based remote viewing over a wireless network. We assessed the diagnostic performance of this system for abdominal CT interpretation. Performance was compared with an emergency department clinical monitor using a DICOM viewer. A total of 100 abdominal CT examinations were presented to four observers. There were 56 examinations showing appendicitis and 44 which were normal. The observers viewed the images using a UMPC display and an LCD monitor and rated each examination on a five-point scale. Receiver operating characteristics (ROC) analysis was used to test for differences. The sensitivity and specificities of all observers were similarly high. The average area under the ROC curve for readings performed on the UMPC and the LCD monitor was 0.959 and 0.976, respectively. There were no significant differences between the two display systems for interpreting abdominal CTs. The web-based mobile teleradiology system appears to be feasible for reading abdominal CTs for diagnosing appendicitis and may be valuable in emergency teleconsultation. Copyright © 2012 by the Royal Society of Medicine Press Ltd

  2. Quantitative CT imaging for adipose tissue analysis in mouse model of obesity

    NASA Astrophysics Data System (ADS)

    Marchadier, A.; Vidal, C.; Tafani, J.-P.; Ordureau, S.; Lédée, R.; Léger, C.

    2011-03-01

    In obese humans CT imaging is a validated method for follow up studies of adipose tissue distribution and quantification of visceral and subcutaneous fat. Equivalent methods in murine models of obesity are still lacking. Current small animal micro-CT involves long-term X-ray exposure precluding longitudinal studies. We have overcome this limitation by using a human medical CT which allows very fast 3D imaging (2 sec) and minimal radiation exposure. This work presents novel methods fitted to in vivo investigations of mice model of obesity, allowing (i) automated detection of adipose tissue in abdominal regions of interest, (ii) quantification of visceral and subcutaneous fat. For each mouse, 1000 slices (100μm thickness, 160 μm resolution) were acquired in 2 sec using a Toshiba medical CT (135 kV, 400mAs). A Gaussian mixture model of the Hounsfield curve of 2D slices was computed with the Expectation Maximization algorithm. Identification of each Gaussian part allowed the automatic classification of adipose tissue voxels. The abdominal region of interest (umbilical) was automatically detected as the slice showing the highest ratio of the Gaussian proportion between adipose and lean tissues. Segmentation of visceral and subcutaneous fat compartments was achieved with 2D 1/2 level set methods. Our results show that the application of human clinical CT to mice is a promising approach for the study of obesity, allowing valuable comparison between species using the same imaging materials and software analysis.

  3. Prior-to-Exam: What Activities Enhance Performance?

    ERIC Educational Resources Information Center

    Rhoads, C. J.; Healy, Therese

    2013-01-01

    Can instructors impact their student performance by recommending an activity just prior to taking an exam? In this study, college students were randomly assigned to one of three treatment groups (study, exercise, or meditation) or a control group. Each group was given two different types of tests; a traditional concept exam, and a non-traditional…

  4. A denoising algorithm for CT image using low-rank sparse coding

    NASA Astrophysics Data System (ADS)

    Lei, Yang; Xu, Dong; Zhou, Zhengyang; Wang, Tonghe; Dong, Xue; Liu, Tian; Dhabaan, Anees; Curran, Walter J.; Yang, Xiaofeng

    2018-03-01

    We propose a denoising method of CT image based on low-rank sparse coding. The proposed method constructs an adaptive dictionary of image patches and estimates the sparse coding regularization parameters using the Bayesian interpretation. A low-rank approximation approach is used to simultaneously construct the dictionary and achieve sparse representation through clustering similar image patches. A variable-splitting scheme and a quadratic optimization are used to reconstruct CT image based on achieved sparse coefficients. We tested this denoising technology using phantom, brain and abdominal CT images. The experimental results showed that the proposed method delivers state-of-art denoising performance, both in terms of objective criteria and visual quality.

  5. Cognitive Difficulty and Format of Exams Predicts Gender and Socioeconomic Gaps in Exam Performance of Students in Introductory Biology Courses

    ERIC Educational Resources Information Center

    Wright, Christian D.; Eddy, Sarah L.; Wenderoth, Mary Pat; Abshire, Elizabeth; Blankenbiller, Margaret; Brownell, Sara E.

    2016-01-01

    Recent reform efforts in undergraduate biology have recommended transforming course exams to test at more cognitively challenging levels, which may mean including more cognitively challenging and more constructed-response questions on assessments. However, changing the characteristics of exams could result in bias against historically underserved…

  6. COAMFTE accreditation and California MFT licensing exam success.

    PubMed

    Caldwell, Benjamin E; Kunker, Shelly A; Brown, Stephen W; Saiki, Dustin Y

    2011-10-01

    Professional accreditation of graduate programs in marital and family therapy (MFT) is intended to ensure the strength of the education students receive. However, there is great difficulty in assessing the real-world impact of accreditation on students. Only one measure is applied consistently to graduates of all MFT programs, regardless of accreditation status: licensure examinations. Within California, COAMFTE-accredited, regionally (WASC) accredited, and state-approved programs all may offer degrees qualifying for licensure. Exam data from 2004, 2005, and 2006 (n = 5,646 examinees on the Written Clinical Vignette exam and n = 3,408 first-time examinees on the Standard Written Exam) were reviewed to determine the differences in exam success among graduates of programs at varying levels of accreditation. Students from COAMFTE-accredited programs were more successful on both California exams than were students from other WASC-accredited or state-approved universities. There were no significant differences between (non-COAMFTE) WASC-accredited universities and state-approved programs. Differences could be related to selection effects, if COAMFTE programs initially accept students of higher quality. Implications for therapist education and training are discussed. © 2011 American Association for Marriage and Family Therapy.

  7. Experience with Online and Open-Web Exams

    ERIC Educational Resources Information Center

    Gehringer, Edward F.; Peddycord, Barry W., III

    2013-01-01

    As homework and other aspects of education migrate to a computer-based format, on-paper exams are beginning to seem like an anachronism. Online delivery is attractive, but comes with a myriad of implications not apparent at first glance. It affects the kinds of questions that can be asked and complicates administration of the exam, but it may make…

  8. Exams disadvantage women in introductory biology

    PubMed Central

    Cotner, Sehoya

    2017-01-01

    The gender gap in STEM fields has prompted a great deal of discussion, but what factors underlie performance deficits remain poorly understood. We show that female students underperformed on exams compared to their male counterparts across ten large introductory biology course sections in fall 2016 (N > 1500 students). Females also reported higher levels of test anxiety and course-relevant science interest. Results from mediation analyses revealed an intriguing pattern: for female students only, and regardless of their academic standing, test anxiety negatively impacted exam performance, while interest in the course-specific science topics increased exam performance. Thus, instructors seeking equitable classrooms can aim to decrease test anxiety and increase student interest in science course content. We provide strategies for mitigating test anxiety and suggestions for alignment of course content with student interest, with the hope of successfully reimagining the STEM pathway as one that is equally accessible to all. PMID:29049334

  9. Convolution-based estimation of organ dose in tube current modulated CT

    NASA Astrophysics Data System (ADS)

    Tian, Xiaoyu; Segars, W. Paul; Dixon, Robert L.; Samei, Ehsan

    2016-05-01

    Estimating organ dose for clinical patients requires accurate modeling of the patient anatomy and the dose field of the CT exam. The modeling of patient anatomy can be achieved using a library of representative computational phantoms (Samei et al 2014 Pediatr. Radiol. 44 460-7). The modeling of the dose field can be challenging for CT exams performed with a tube current modulation (TCM) technique. The purpose of this work was to effectively model the dose field for TCM exams using a convolution-based method. A framework was further proposed for prospective and retrospective organ dose estimation in clinical practice. The study included 60 adult patients (age range: 18-70 years, weight range: 60-180 kg). Patient-specific computational phantoms were generated based on patient CT image datasets. A previously validated Monte Carlo simulation program was used to model a clinical CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). A practical strategy was developed to achieve real-time organ dose estimation for a given clinical patient. CTDIvol-normalized organ dose coefficients ({{h}\\text{Organ}} ) under constant tube current were estimated and modeled as a function of patient size. Each clinical patient in the library was optimally matched to another computational phantom to obtain a representation of organ location/distribution. The patient organ distribution was convolved with a dose distribution profile to generate {{≤ft(\\text{CTD}{{\\text{I}}\\text{vol}}\\right)}\\text{organ, \\text{convolution}}} values that quantified the regional dose field for each organ. The organ dose was estimated by multiplying {{≤ft(\\text{CTD}{{\\text{I}}\\text{vol}}\\right)}\\text{organ, \\text{convolution}}} with the organ dose coefficients ({{h}\\text{Organ}} ). To validate the accuracy of this dose estimation technique, the organ dose of the original clinical patient was estimated using Monte Carlo program with TCM profiles explicitly modeled. The

  10. Exam Question Exchange.

    ERIC Educational Resources Information Center

    Alexander, John J., Ed.

    1978-01-01

    Two exam questions are presented. One suitable for advanced undergraduate or beginning graduate courses in organic chemistry, is on equivalent expressions for the description of several pericyclic reactions. The second, for general chemistry students, asks for an estimation of the rate of decay of a million-year-old Uranium-238 sample. (BB)

  11. Prospective estimation of organ dose in CT under tube current modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Xiaoyu, E-mail: xt3@duke.edu; Li, Xiang; Segars, W. Paul

    library; (3) to account for the effect of the TCM scheme, a weighted organ-specific CTDI{sub vol} [denoted as (CTDI{sub vol}){sub organ,weighted}] was computed for each organ based on the TCM profile and the anatomy of the “matched” phantom; (4) the organ dose was predicted by multiplying the weighted organ-specific CTDI{sub vol} with the organ dose coefficients (h{sub organ}). To quantify the prediction accuracy, each predicted organ dose was compared with the corresponding organ dose simulated from the Monte Carlo program with the TCM profile explicitly modeled. Results: The predicted organ dose showed good agreements with the simulated organ dose across all organs and modulation profiles. The average percentage error in organ dose estimation was generally within 20% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. For an average CTDI{sub vol} of a CT exam of 10 mGy, the average error at full modulation strength (α = 1) across all organs was 0.91 mGy for chest exams, and 0.82 mGy for abdominopelvic exams. Conclusions: This study developed a quantitative model to predict organ dose for clinical chest and abdominopelvic scans. Such information may aid in the design of optimized CT protocols in relation to a targeted level of image quality.« less

  12. Abdominal wall desmoid tumors: A case report

    PubMed Central

    MA, JIN-HUI; MA, ZHEN-HAI; DONG, XUE-FENG; YIN, HANG; ZHAO, YONG-FU

    2013-01-01

    Desmoid tumors (DTs) are rare lesions that do not possess any metastatic potential. However, they have a strong tendency to invade locally and recur. They constitute 3% of all soft tissue tumors and 0.03% of all neoplasms. Abdominal DTs occur sporadically or are associated with certain familial syndromes, such as familial adenomatous polyposis (FAP). The single form of this neoplasm most frequently occurs in females of reproductive age and during pregnancy. A female patient with a DT of the abdominal wall who had no relevant family history was admitted to hospital. The patient, who presented with a painless mass in the left anterolateral abdomen, had no history of trauma, surgery or childbearing. According to the medical history, physical examination and CT report, the patient was diagnosed with DT. Radical resection of the affected abdominal wall musculature was performed, and the defect was replaced with a polypropylene mesh. The histological diagnosis was of DT. The patient remains in good health and complete remission without any other treatment following surgery. DTs exhibit aggressive growth and have a high rate of recurrence. Surgery is the optimal treatment, and subsequent radiotherapy may decrease the local recurrence rate. Further research into their aetiology is required combined with multicentre clinical trials of new treatments in order to improve management of this disease. This case report provides general knowledge of DT, and may be used as a guidance for diagnosis and treatment. PMID:23833679

  13. SU-E-I-32: Benchmarking Head CT Doses: A Pooled Vs. Protocol Specific Analysis of Radiation Doses in Adult Head CT Examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujii, K; UCLA School of Medicine, Los Angeles, CA; Bostani, M

    Purpose: The aim of this study was to collect CT dose index data from adult head exams to establish benchmarks based on either: (a) values pooled from all head exams or (b) values for specific protocols. One part of this was to investigate differences in scan frequency and CT dose index data for inpatients versus outpatients. Methods: We collected CT dose index data (CTDIvol) from adult head CT examinations performed at our medical facilities from Jan 1st to Dec 31th, 2014. Four of these scanners were used for inpatients, the other five were used for outpatients. All scanners used Tubemore » Current Modulation. We used X-ray dose management software to mine dose index data and evaluate CTDIvol for 15807 inpatients and 4263 outpatients undergoing Routine Brain, Sinus, Facial/Mandible, Temporal Bone, CTA Brain and CTA Brain-Neck protocols, and combined across all protocols. Results: For inpatients, Routine Brain series represented 84% of total scans performed. For outpatients, Sinus scans represented the largest fraction (36%). The CTDIvol (mean ± SD) across all head protocols was 39 ± 30 mGy (min-max: 3.3–540 mGy). The CTDIvol for Routine Brain was 51 ± 6.2 mGy (min-max: 36–84 mGy). The values for Sinus were 24 ± 3.2 mGy (min-max: 13–44 mGy) and for Facial/Mandible were 22 ± 4.3 mGy (min-max: 14–46 mGy). The mean CTDIvol for inpatients and outpatients was similar across protocols with one exception (CTA Brain-Neck). Conclusion: There is substantial dose variation when results from all protocols are pooled together; this is primarily a function of the differences in technical factors of the protocols themselves. When protocols are analyzed separately, there is much less variability. While analyzing pooled data affords some utility, reviewing protocols segregated by clinical indication provides greater opportunity for optimization and establishing useful benchmarks.« less

  14. Pathologic aerophagia: a rare cause of chronic abdominal distension

    PubMed Central

    de Jesus, Lisieux Eyer; Cestari, Ana Beatriz C.S.S.; da Silva, Orli Carvalho; Fernandes, Marcia Antunes; Firme, Livia Honorato

    2015-01-01

    Objective: To describe an adolescent with pathologic aerophagia, a rare condition caused by excessive and inappropriate swallowing of air and to review its treatment and differential diagnoses. Case description: An 11-year-old mentally impaired blind girl presenting serious behavior problems and severe developmental delay with abdominal distension from the last 8 months. Her past history included a Nissen fundoplication. Abdominal CT and abdominal radiographs showed diffuse gas distension of the small bowel and colon. Hirschsprung's disease was excluded. The distention was minimal at the moment the child awoke and maximal at evening, and persisted after control of constipation. Audible repetitive and frequent movements of air swallowing were observed. The diagnosis of pathologic aerophagia associated to obsessive-compulsive disorder and developmental delay was made, but pharmacological treatment was unsuccessful. The patient was submitted to an endoscopic gastrostomy, permanently opened and elevated relative to the stomach. The distention was resolved, while maintaining oral nutrition. Comments: Pathologic aerophagia is a rare self-limiting condition in normal children exposed to high levels of stress and may be a persisting problem in children with psychiatric or neurologic disease. In this last group, the disease may cause serious complications. Pharmacological and behavioral treatments are ill-defined. Severe cases may demand surgical strategies, mainly decompressive gastrostomy. PMID:26100594

  15. Effect of Paper Color and Question Order on Exam Performance

    ERIC Educational Resources Information Center

    Tal, Ilanit R.; Akers, Katherine G.; Hodge, Gordon K.

    2008-01-01

    To deter cheating, teachers commonly use exams printed on differently colored paper or with varied question orders. Previous studies, however, reported that paper color and question order affect exam performance and suggested that teachers should adjust students' scores accordingly and discontinue the use of alternate exam forms. We conducted 2…

  16. Does Question Structure Affect Exam Performance in the Geosciences?

    NASA Astrophysics Data System (ADS)

    Day, E. A.; D'Arcy, M. K.; Craig, L.; Streule, M. J.; Passmore, E.; Irving, J. C. E.

    2015-12-01

    The jump to university level exams can be challenging for some students, often resulting in poor marks, which may be detrimental to their confidence and ultimately affect their overall degree class. Previous studies have found that question structure can have a strong impact on the performance of students in college level exams (see Gibson et al., 2015, for a discussion of its impact on physics undergraduates). Here, we investigate the effect of question structure on the exam results of geology and geophysics undergraduate students. Specifically, we analyse the performance of students in questions that have a 'scaffolded' framework and compare them to their performance in open-ended questions and coursework. We also investigate if observed differences in exam performance are correlated with the educational background and gender of students, amongst other factors. It is important for all students to be able to access their degree courses, no matter what their backgrounds may be. Broadening participation in the geosciences relies on removing systematic barriers to achievement. Therefore we recommend that exams are either structured with scaffolding in questions at lower levels, or students are explicitly prepared for this transition. We also recommend that longitudinal studies of exam performance are conducted within individual departments, and this work outlines one approach to analysing performance data.

  17. Dapagliflozin significantly reduced liver fat accumulation associated with a decrease in abdominal subcutaneous fat in patients with inadequately controlled type 2 diabetes mellitus.

    PubMed

    Kurinami, Noboru; Sugiyama, Seigo; Yoshida, Akira; Hieshima, Kunio; Miyamoto, Fumio; Kajiwara, Keizo; Jinnouch, Katsunori; Jinnouchi, Tomio; Jinnouchi, Hideaki

    2018-05-31

    We examined dapagliflozin-induced changes in liver fat accumulation. We prospectively recruited Japanese patients with inadequately controlled type 2 diabetes mellitus (T2DM) [hemoglobin A1c (HbA1c) >7.0%]. Dapagliflozin (5 mg/day) or non-sodium glucose cotransporter 2 inhibitors (SGLT2i) was added to the patients' treatment regimen for 6 months. Changes in liver fat accumulation were assessed by the liver-to-spleen (L/S) attenuation ratio using abdominal computed tomography (CT). This study enrolled 55 Japanese T2DM patients. The L/S ratio significantly increased in the dapagliflozin group compared with the non-SGLT2i group. Abdominal subcutaneous fat area (SFA), visceral fat area, total fat area assessed by abdominal CT, aspartate aminotransferase, alanine aminotransferase (ALT), and γ-glutamyl transpeptidase decreased significantly only in the dapagliflozin group. Changes in the L/S ratio showed a significant negative relationship with changes in abdominal SFA, ALT, and non-esterified fatty acid. In sub-group analyses of non-insulin users, hepatic insulin extraction was assessed by the plasma C-peptide-to-insulin ratio, which was significantly increased in the dapagliflozin group but not in the non-SGLT2i group. In patients with inadequately controlled T2DM, additional dapagliflozin-treatment significantly reduced the liver fat accumulation associated with a decrease in abdominal SFA. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Research participation improves student's exam performance.

    PubMed

    Gil-Gómez de Liaño, Beatriz; León, Orfelio G; Pascual-Ezama, David

    2012-07-01

    Although there have been several attempts to explore for beneficial effects of research participation in social sciences, most of them have mainly explored satisfaction and students learning perceptions (e.g., Bowman & Waite, 2003). Very few works have studied learning by measuring exam performance. Moreover, participation has been usually conceptualized as a mixture of active and passive participation, including in the same measure different practices such as filling up questionnaires, running experiments or reading and answering questions about a journal article or a scientific conference. The present work tries to determine if there is an advantage due to research participation comparing exam performance, satisfaction and perceived learning of the matter Research Methods in Psychology, in three different groups (non-participating, passive and active participating). As we can see in the results, the mere participation benefits exam performance. Results are discussed in terms of the use of research participation as a new powerful active method in education.

  19. CT Fluoroscopy Shielding: Decreases in Scattered Radiation for the Patient and Operator

    PubMed Central

    Neeman, Ziv; Dromi, Sergio A.; Sarin, Shawn; Wood, Bradford J.

    2008-01-01

    PURPOSE High-radiation exposure occurs during computed tomographic (CT) fluoroscopy. Patient and operator doses during thoracic and abdominal interventional procedures were studied in the present experiment, and a novel shielding device to reduce exposure to the patient and operator was evaluated. MATERIALS AND METHODS With a 16-slice CT scanner in CT fluoroscopy mode (120 kVp, 30 mA), surface dosimetry was performed on adult and pediatric phantoms. The shielding was composed of tungsten antimony in the form of a lightweight polymer sheet. Doses to the patient were measured with and without shielding for thoracic and abdominal procedures. Doses to the operator were recorded with and without phantom, gantry, and table shielding in place. Double-layer lead-free gloves were used by the operator during the procedures. RESULTS Tungsten antimony shielding adjacent to the scan plane resulted in a maximum dose reduction of 92.3% to the patient. Maximum 85.6%, 93.3%, and 85.1% dose reductions were observed for the operator’s torso, gonads, and hands, respectively. The use of double-layer lead-free gloves resulted in a maximum radiation dose reduction of 97%. CONCLUSIONS Methods to reduce exposure during CT fluoroscopy are effective and should be searched for. Significant reduction in radiation doses to the patient and operator can be accomplished with tungsten antimony shielding. PMID:17185699

  20. Management of intra-abdominal hypertension and abdominal compartment syndrome: a review

    PubMed Central

    2014-01-01

    Patients in the intensive care unit (ICU) are at risk of developing of intra abdominal hypertension (IAH) and abdominal compartment syndrome (ACS). Aim: This review seeks to define IAH and ACS, identify the aetiology and presentation of IAH and ACS, identify IAP measurement techniques, identify current management and discuss the implications of IAH and ACS for nursing practice. A search of the electronic databases was supervised by a health librarian. The electronic data bases Cumulative Index of Nursing and Allied Health Literature (CINAHL); Medline, EMBASE, and the World Wide Web was undertaken from 1996- January 2011 using MeSH and key words which included but not limited to: abdominal compartment syndrome, intra -abdominal hypertension, intra-abdominal pressure in adult populations met the search criteria and were reviewed by three authors using a critical appraisal tool. Data derived from the retrieved material are discussed under the following themes: (1) etiology of intra-abdominal hypertension; (2) strategies for measuring intra-abdominal pressure (3) the manifestation of abdominal compartment syndrome; and (4) the importance of nursing assessment, observation and interventions. Intra-abdominal pressure (IAP) and abdominal compartment syndrome (ACS) have the potential to alter organ perfusion and compromise organ function. PMID:24499574

  1. Providing Opportunities for Argumentation in Science Exam Settings

    ERIC Educational Resources Information Center

    Swanson, Lauren; Solorza, Ruben; Fissore, Cinzia

    2018-01-01

    This article explores undergraduates' efforts to engage in scientific argumentation during exam settings. Thirteen undergraduate students enrolled in an environmental science course completed exams with questions linked around a central theme. Three types of questions were used, including those that prompted students to construct scientific…

  2. [Centrally and non-centrally designed exams in nursing: Comparisons of the final exams in 2008 to 2013 in Berlin focusing on different concepts of professional nursing education].

    PubMed

    Strube-Lahmann, Sandra; Vogler, Christine; Friedrich, Kai; Dassen, Theo; Kottner, Jan

    2016-12-01

    In Germany, nursing education ends with a final written, oral and practical exam. In the federal state of Berlin, Germany, all nursing students take centrally standardized written exams, while the practical and oral exams are developed by each individual nursing school or university and conducted without standardized protocols (non-central). Comparability might be seriously limited by this procedure. Since there is no official statistics available, the objective of this study is to compare the results of the final written, oral and practical exams of different nursing education institutions with an additional focus on different educational concepts. In a secondary data analysis, the final grades (written, oral, practical) of 4,342 nursing students in all 16 educational institutions in Berlin from 2008 to 2013 were analyzed. The mean (SD) of all written, oral and practical exams taken was 2.9 (0.7), 2.6 (1.1) and 2.2 (1.0), respectively. In each type of exam, the trend in grades was stable over the observation period. There was a statistically significant increase in the prevalence of initially failed exams from 2008 (7.9 %) to 2013 (12.0 %). In institutions following a traditional concept of education, the difference in grades between oral/practical exams on the one hand and written exams on the other ranged from 0.1 to 0.9, while in generalist (academic) institutions it ranged between -0.1 and 0.3 (-0.1 to 0). In nursing schools with a traditional approach to education, there was a big difference in grades between written and oral/practical exams. Standardization of oral and practical exams should be initiated to ensure greater comparability between different educational institutions. Copyright © 2016. Published by Elsevier GmbH.

  3. Unusual case of iron overload with cancer-mimicking abdominal splenosis.

    PubMed

    Marchi, Giacomo; Avesani, Giacomo; Zamò, Alberto; Girelli, Domenico

    2018-05-16

    A 48-year-old man, former alcohol abuser and drug addicted, was referred to our tertiary referral centre for iron disorders because of marked hyperferritinaemia. His clinical history revealed chronic hepatitis C, ß-thalassaemia trait and post-traumatic splenectomy at age of 22. MRI-estimated liver iron content was markedly elevated, while first-line genetic test for haemochromatosis was negative. Alpha-fetoprotein was increased but liver ultrasonography did not reveal focal liver lesions. Multiphasic contrast-enhanced CT confirmed this result but showed two abdominal masses (diameter of 9 cm and 7 cm, respectively) among bowel loops, strongly suspicious for cancer. However, biopsy of one of the masses led to the final diagnosis of abdominal splenosis. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Even after Thirteen Class Exams, Students Are Still Overconfident: The Role of Memory for Past Exam Performance in Student Predictions

    ERIC Educational Resources Information Center

    Foster, Nathaniel L.; Was, Christopher A.; Dunlosky, John; Isaacson, Randall M.

    2017-01-01

    Students often are overconfident when they predict their performance on classroom examinations, and their accuracy often does not improve across exams. One contributor to overconfidence may be that students did not have enough experience, and another is that students may under-use their knowledge of prior exam performance to predict performance on…

  5. Feasibility Study of a Novel Thoraco-abdominal Aortic Hybrid Device (SPIDER-graft) in a Translational Pig Model.

    PubMed

    Debus, Eike S; Kölbel, Tilo; Duprée, Anna; Daum, Günter; Sandhu, Harleen K; Manzoni, Daniel; Wipper, Sabine H

    2018-02-01

    The hybrid SPIDER-graft consists of a proximal descending aortic stent graft and a conventional six branched Dacron graft for open abdominal aortic repair. Technical feasibility with regard to avoiding thoracotomy and extracorporeal circulation (ECC) during thoraco-abdominal aortic hybrid repair and peri-procedural safety of this novel device are unknown. This was a feasibility and safety study in domestic pigs (75-85 kg). The abdominal aorta including iliac bifurcation, left renal artery, and visceral arteries were exposed via retroperitoneal access. The right iliac branch was first temporarily anastomosed end to side to the distal aorta via partial clamping. During inflow reduction and infra-coeliac cross-clamping, the coeliac trunk (CT) was divided and the proximal stent graft portion of the SPIDER-graft was deployed into the descending aorta via the CT ostium. Retrograde visceral and antegrade aorto-iliac blood flow was maintained via the iliac side branch. The visceral, renal, and iliac arteries were sequentially anastomosed, finally replacing the first iliac end to side anastomosis. Technical success, blood flow, periods of ischaemia, and peri-procedural complications were evaluated after intra-operative completion angiography and post-operative computed tomography angiography. Six animals underwent successful thoracic stent graft deployment and distal open reconstruction without peri-operative death. The median thoracic graft implantation time was 4.5 min, and the median ischaemia times before reperfusion were 10 min for the CT, 8 min for the superior mesenteric artery, 13 min for the right renal artery, and 22 min for the left renal artery. Angiography demonstrated appropriate graft implantation and blood flow measurements confirmed sufficient blood flow through all side branches. In this translational pig model, thoraco-abdominal hybrid repair using the novel SPIDER-graft was successful in avoiding thoracotomy and ECC. Technical feasibility and

  6. X-Ray Exam: Bone Age Study (For Parents)

    MedlinePlus

    ... for Educators Search English Español X-Ray Exam: Bone Age Study KidsHealth / For Parents / X-Ray Exam: Bone Age Study What's in this article? What It ... de la edad ósea What It Is A bone age study helps doctors estimate the maturity of ...

  7. The Cognitive Abilities of Children: Reflections from an Entrance Exam

    ERIC Educational Resources Information Center

    Cil, Emine; Cepni, Salih

    2012-01-01

    The basic determiner for the school in which the children who completed their primary education will in at an upper education level in Turkey is the entrance exam carried out nationwide. The items of national exam, called as LDE (Level Determination Exam) which the primary education pupils (aged between 12 and 15) will participate in Turkey were…

  8. Validity, Reliability and Difficulty Indices for Instructor-Built Exam Questions

    ERIC Educational Resources Information Center

    Jandaghi, Gholamreza; Shaterian, Fatemeh

    2008-01-01

    The purpose of the research is to determine college Instructor's skill rate in designing exam questions in chemistry subject. The statistical population was all of chemistry exam sheets for two semesters in one academic year from which a sample of 364 exam sheets was drawn using multistage cluster sampling. Two experts assessed the sheets and by…

  9. [International family medicine certification exam in Venezuela: the physician's experience].

    PubMed

    Ledesma-Solaeche, Flor Maria; Romero, Nerio Enrique; Atencio, Carlos Miguel; Pineda, Francisco; Fernández, Miguel Angel

    2006-01-01

    To present opinions of physicians participating in a pilot certification exam in the specialty of Family Medicine implemented in Venezuela, in December 2004, by the Mexican Board of Certification of Family Medicine A.C. Descriptive, transversal. Participant physicians (n:37) completed semi-structured questionnaries: one or two weeks before the exam, and immediately after it. 60% of participants were 41-50 years old and 80% women. All of them were practicing physicians; 49% had 5-10 year experience in family medicine. Main motivation to participate in the exam: the need for continuing learning (83%). Results showed their participation motivated continuing education (46%). Books were the most frequently utilized resource when preparing for the exam (54%). 94% were willing to take the exam again in the future, and all would recommend it to their colleagues. 49% said that examination should be taken every 3-4 years and should be voluntary (54%). 86% considered the content of the exam pertinent to their practice while 54% mentioned it was well adapted to their country's reality. Time for the exam was enough according to 71%, and number of questions was considered excessive by 89%. After the exam, 43% estimated to have personal prognosis for excellent or good outcomes. CONCLUSIONS. The international examination was satisfactory, stimulated desires of update, and the participants would repeat and recommend it in the future. The Mexican experience offers an example to put into practice, and the international collaboration would be a valid option to extend the certification processes in Latin America.

  10. Effect of Abdominal Ultrasound on Clinical Care, Outcomes, and Resource Use Among Children With Blunt Torso Trauma: A Randomized Clinical Trial.

    PubMed

    Holmes, James F; Kelley, Kenneth M; Wootton-Gorges, Sandra L; Utter, Garth H; Abramson, Lisa P; Rose, John S; Tancredi, Daniel J; Kuppermann, Nathan

    2017-06-13

    The utility of the focused assessment with sonography for trauma (FAST) examination in children is unknown. To determine if the FAST examination during initial evaluation of injured children improves clinical care. A randomized clinical trial (April 2012-May 2015) that involved 975 hemodynamically stable children and adolescents younger than 18 years treated for blunt torso trauma at the University of California, Davis Medical Center, a level I trauma center. Patients were randomly assigned to a standard trauma evaluation with the FAST examination by the treating ED physician or a standard trauma evaluation alone. Coprimary outcomes were rate of abdominal computed tomographic (CT) scans in the ED, missed intra-abdominal injuries, ED length of stay, and hospital charges. Among the 925 patients who were randomized (mean [SD] age, 9.7 [5.3] years; 575 males [62%]), all completed the study. A total of 50 patients (5.4%, 95% CI, 4.0% to 7.1%) were diagnosed with intra-abdominal injuries, including 40 (80%; 95% CI, 66% to 90%) who had intraperitoneal fluid found on an abdominal CT scan, and 9 patients (0.97%; 95% CI, 0.44% to 1.8%) underwent laparotomy. The proportion of patients with abdominal CT scans was 241 of 460 (52.4%) in the FAST group and 254 of 465 (54.6%) in the standard care-only group (difference, -2.2%; 95% CI, -8.7% to 4.2%). One case of missed intra-abdominal injury occurred in a patient in the FAST group and none in the control group (difference, 0.2%; 95% CI, -0.6% to 1.2%). The mean ED length of stay was 6.03 hours in the FAST group and 6.07 hours in the standard care-only group (difference, -0.04 hours; 95% CI, -0.47 to 0.40 hours). Median hospital charges were $46 415 in the FAST group and $47 759 in the standard care-only group (difference, -$1180; 95% CI, -$6651 to $4291). Among hemodynamically stable children treated in an ED following blunt torso trauma, the use of FAST compared with standard care only did not improve clinical care, including

  11. Impact of low-energy CT imaging on selection of positive oral contrast media concentration.

    PubMed

    Patino, Manuel; Murcia, Diana J; Iamurri, Andrea Prochowski; Kambadakone, Avinash R; Hahn, Peter F; Sahani, Dushyant V

    2017-05-01

    To determine to what extent low-energy CT imaging affects attenuation of gastrointestinal tract (GIT) opacified with positive oral contrast media (OCM). Second, to establish optimal OCM concentrations for low-energy diagnostic CT exams. One hundred patients (38 men and 62 women; age 62 ± 11 years; BMI 26 ± 5) with positive OCM-enhanced 120-kVp single-energy CT (SECT), and follow-up 100-kVp acquisitions (group A; n = 50), or 40-70-keV reconstructions from rapid kV switching-single-source dual-energy CT (ssDECT) (group B; n = 50) were included. Luminal attenuation from different GIT segments was compared between exams. Standard dose of three OCM and diluted solutions (75%, 50%, and 25% concentrations) were introduced serially in a gastrointestinal phantom and scanned using SECT (120, 100, and 80 kVp) and DECT (80/140 kVp) acquisitions on a ssDECT scanner. Luminal attenuation was obtained on SECT and DECT images (40-70 keV), and compared to 120-kVp scans with standard OCM concentrations. Luminal attenuation was higher on 100-kVp (328 HU) and on 40-60-keV images (410-924 HU) in comparison to 120-kVp scans (298 HU) in groups A and B (p < 0.05). Phantom: There was an inverse correlation between luminal attenuation and X-ray energy, increasing up to 527 HU on low-kVp and 999 HU on low-keV images (p < 0.05). 25% and 50% diluted OCM solutions provided similar or higher attenuation than 120 kVp, at low kVp and keV, respectively. Low-energy CT imaging increases the attenuation of GIT opacified with positive OCM, permitting reduction of 25%-75% OCM concentration.

  12. [Acute right-sided upper abdominal pain in a 46-year-old woman].

    PubMed

    Bauder, M; Fiala, A; Klinger, C; Kersjes, W; Caca, K

    2018-02-01

    A 46-year-old woman presented with acute abdominal pain in the right upper quadrant. Esophagogastroduodenoscopy revealed a duodenal stenosis within the horizontal part of the duodenum. Based on the findings of abdominal computed tomography (CT), endosonography, Doppler duplex sonography and angiography, the diagnosis of an aneurysm of a branch of the inferior pancreaticoduodenal artery was established. This arterial branch was part of a collateral circulation between the superior mesenteric artery and the proper hepatic artery caused by obturation of the celiac artery. The symptomatic duodenal stenosis was the result of a local hematoma due to prior rupture of an aneurysm. After successful coiling of the afferent vessels to the aneurysm follow-up examinations showed progredient resorption of the hematoma and the patient was free of complaints.

  13. [Diagnosis and differential diagnosis for solitary fibrous tumor in the abdomen and pelvis by CT].

    PubMed

    Liu, Huaping; Li, Wenzheng; Yi, Xiaoping; Pei, Yigang; Liu, Hui; Zhao, Wei; Liu, Wenguang; Hou, Jiale; Ghimire, Obin

    2017-04-28

    To study the CT features for solitary fibrous tumor (SFT) in the abdomen and pelvis and to improve the diagnostic accuracy.
 Methods: Fourteen patients with SFT were collected in our hospital from January, 2011 to December, 2015. Characteristic of images were analyzed and compared for 10 SFT, which located outside the abdominal organs with extragastrointestinal stromal tumors (EGIST), leiomyosarcoma, and schwannoma.
 Results: Necrosis and cystic formation were frequently present in SFT in the abdomen and pelvis. CE-CT showed serpentine vessels along the periphery, while pattern of enhancement was map-like inhomogeneous progressive. Comparing with the EGIST or schwannoma, the difference of CT value in non-contrast and the arterial phase were statistically significant (P<0.05). The numbers of peritumoral circuity vessel were significantly different between SFT and EGIST (χ²=18.27, P<0.008) or between SFT and schwannoma (χ²=19.25, P<0.008). Comparing with the leiomyosarcoma or schwannoma, SFT located outside the abdominal organs. We found that tumor necrosis rate was significantly different between SFT and leiomyoscarcoma (χ²=8.00, P<0.008).
 Conclusion: SFT in the abdomen and pelvis show certain CT characteristics. The CT value in non-contrast and at the arterial phase, tumor necrosis rate, and serpentine vessels along the periphery were pivotal in differentiating SFT from leiomyosarcoma, EGIST and schwannoma.

  14. Effect of staff training on radiation dose in pediatric CT.

    PubMed

    Hojreh, Azadeh; Weber, Michael; Homolka, Peter

    2015-08-01

    To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen-pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p<0.01). This trend could be demonstrated also for trunk scans, however, significance could not be established due to low patient frequencies (p>0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal-pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen-pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs - available only for CCT and thorax CT - showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Abdominal injuries in a low trauma volume hospital - a descriptive study from northern Sweden

    PubMed Central

    2014-01-01

    Background Abdominal injuries occur relatively infrequently during trauma, and they rarely require surgical intervention. In this era of non-operative management of abdominal injuries, surgeons are seldom exposed to these patients. Consequently, surgeons may misinterpret the mechanism of injury, underestimate symptoms and radiologic findings, and delay definite treatment. Here, we determined the incidence, diagnosis, and treatment of traumatic abdominal injuries at our hospital to provide a basis for identifying potential hazards in non-operative management of patients with these injuries in a low trauma volume hospital. Methods This retrospective study included prehospital and in-hospital assessments of 110 patients that received 147 abdominal injuries from an isolated abdominal trauma (n = 70 patients) or during multiple trauma (n = 40 patients). Patients were primarily treated at the University Hospital of Umeå from January 2000 to December 2009. Results The median New Injury Severity Score was 9 (range: 1–57) for 147 abdominal injuries. Most patients (94%) received computed tomography (CT), but only 38% of patients with multiple trauma were diagnosed with CT < 60 min after emergency room arrival. Penetrating trauma caused injuries in seven patients. Solid organ injuries constituted 78% of abdominal injuries. Non-operative management succeeded in 82 patients. Surgery was performed for 28 patients, either immediately (n = 17) as result of operative management or later (n = 11), due to non-operative management failure; the latter mainly occurred with hollow viscus injuries. Patients with multiple abdominal injuries, whether associated with multiple trauma or an isolated abdominal trauma, had significantly more non-operative failures than patients with a single abdominal injury. One death occurred within 30 days. Conclusions Non-operative management of patients with abdominal injuries, except for hollow viscus injuries, was highly

  16. Abdominal epilepsy as an unusual cause of abdominal pain: a case report.

    PubMed

    Yunus, Yilmaz; Sefer, Ustebay; Dondu, Ulker Ustebay; Ismail, Ozanli; Yusuf, Ehi

    2016-09-01

    Abdominal pain, in etiology sometimes difficult to be defined, is a frequent complaint in childhood. Abdominal epilepsy is a rare cause of abdominal pain. In this article, we report on 5 year old girl patient with abdominal epilepsy. Some investigations (stool investigation, routine blood tests, ultrasonography (USG), electrocardiogram (ECHO) and electrocardiograpy (ECG), holter for 24hr.) were done to understand the origin of these complaints; but no abnormalities were found. Finally an EEG was done during an episode of abdominal pain and it was shown that there were generalized spikes especially precipitated by hyperventilation. The patient did well on valproic acid therapy and EEG was normal 1 month after beginning of the treatment. The cause of chronic recurrent paroxymal abdominal pain is difficult for the clinicians to diagnose in childhood. A lot of disease may lead to paroxysmal gastrointestinal symptoms like familial mediterranean fever and porfiria. Abdominal epilepsy is one of the rare but easily treatable cause of abdominal pain. In conclusion, abdominal epilepsy should be suspected in children with recurrent abdominal pain.

  17. Exam 2 Strategy

    ERIC Educational Resources Information Center

    Cummings, Richard G.; Gruber, Robert A.

    2006-01-01

    After students take their first exam in an accounting course, tax accounting and intermediate accounting in this case, their reactions to their test scores may be varied. This is their first major assessment of how they have performed in the class. The students in the class near the high end of the grading scale are going to be satisfied with…

  18. Hepatic enzymes have a role in the diagnosis of hepatic injury after blunt abdominal trauma.

    PubMed

    Tan, Ker-Kan; Bang, Shieh-Ling; Vijayan, Appasamy; Chiu, Ming-Terk

    2009-09-01

    Delayed diagnosis of patients with severe liver injuries is associated with an adverse outcome. As computed tomographic (CT) scan is not always available in the management of blunt abdominal trauma worldwide, the present study was undertaken to determine the accuracy of selected haematological markers in predicting the presence of hepatic injury and its severity after blunt abdominal trauma. A retrospective review of all patients with blunt abdominal trauma presented to our institution over a 3-year period was performed. Patients were excluded if they suffered penetrating injuries, died in the emergency department or if the required blood tests were not performed within 24h of the accident. The grading of the hepatic injury was verified using CT scans or surgical findings. Ninety-nine patients with blunt abdominal trauma had the required blood tests performed and were included in the study. The median injury severity score was 24 (range 4-75). Fifty-five patients had hepatic injuries, of which 47.3% were minor (Grades I and II) while 52.7% had major hepatic injuries (Grades III-V). There were no patients with Grade VI injuries. A raised ALT was strongly associated with presence of hepatic injuries (OR, 109.8; 95% CI, 25.81-466.9). This relation was also seen in patients with raised AST>2 times (OR, 21.33; 95% CI, 7.27-62.65). This difference was not seen in both bilirubin and ALP. ALT>2 times normal was associated with major hepatic injuries (OR, 7.15; 95% CI, 1.38-37.14; p=0.012) while patients with simultaneous raised AST>2 times and ALT>2 times had a stronger association for major hepatic injuries (OR, 8.44; 95% CI, 1.64-43.47). Abnormal transaminases levels are associated with hepatic injuries after blunt abdominal trauma. Patients with ALT and AST>2 times normal should be assumed to possess major hepatic trauma and managed accordingly. Patients with normal ALT, AST and LDH are unlikely to have major liver injuries.

  19. A Pilot Study of an Electronic Exam System at an Australian University

    ERIC Educational Resources Information Center

    Wibowo, Santoso; Grandhi, Srimannarayana; Chugh, Ritesh; Sawir, Erlenawati

    2016-01-01

    This study sought academic staff and students' views of electronic exams (e-exams) system and the benefits and challenges of e-exams in general. The respondents provided useful feedback for future adoption of e-exams at an Australian university and elsewhere too. The key findings show that students and academic staff are optimistic about the…

  20. Standardized anatomic space for abdominal fat quantification

    NASA Astrophysics Data System (ADS)

    Tong, Yubing; Udupa, Jayaram K.; Torigian, Drew A.

    2014-03-01

    The ability to accurately measure subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) from images is important for improved assessment and management of patients with various conditions such as obesity, diabetes mellitus, obstructive sleep apnea, cardiovascular disease, kidney disease, and degenerative disease. Although imaging and analysis methods to measure the volume of these tissue components have been developed [1, 2], in clinical practice, an estimate of the amount of fat is obtained from just one transverse abdominal CT slice typically acquired at the level of the L4-L5 vertebrae for various reasons including decreased radiation exposure and cost [3-5]. It is generally assumed that such an estimate reliably depicts the burden of fat in the body. This paper sets out to answer two questions related to this issue which have not been addressed in the literature. How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? At what anatomic location do the volumes of SAT and VAT correlate maximally with the corresponding single-slice area measures? To answer these questions, we propose two approaches for slice localization: linear mapping and non-linear mapping which is a novel learning based strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. We then study the volume-to-area correlations and determine where they become maximal. We demonstrate on 50 abdominal CT data sets that this mapping achieves significantly improved consistency of anatomic localization compared to current practice. Our results also indicate that maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized.

  1. Final Exam Weighting as Part of Course Design

    ERIC Educational Resources Information Center

    Franke, Matthew

    2018-01-01

    The weighting of a final exam or a final assignment is an essential part of course design that is rarely discussed in pedagogical literature. Depending on the weighting, a final exam or assignment may provide unequal benefits to students depending on their prior performance in the class. Consequently, uncritical grade weighting can discount…

  2. Gender Differences in STEM Related Advanced Placement Exams

    ERIC Educational Resources Information Center

    Morris, Jill B.

    2013-01-01

    Purpose: The purpose of this study was to examine differences between boys and girls in their performance on STEM related AP exams. Specifically, gender differences were examined for the following STEM related AP exams: Calculus AB, Calculus BC, Physics B, Physics C: Electricity and Magnetism, Physics C: Mechanics, Chemistry, and Computer Science…

  3. Endovascular Repair of a Pseudoaneurysm of the Abdominal Aorta Secondary to Translumbar Aortography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mir, Naheed; Nunzio, Mario De; Pollock, John G

    This report describes an incidental finding of a pseudoaneurysm of the abdominal aorta on a computed tomography (CT) renal angiogram during investigation of chronic renal failure in a 73-year-old man. The patient had undergone a translumbar aortogram 20 years previously. An increase in the size of the aneurysm by 7 mm over 6 months prompted treatment and the aneurysm underwent successful endovascular repair with a custom-made stent-graft.

  4. Intra-Abdominal Hypertension and Abdominal Compartment Syndrome in Association with Ruptured Abdominal Aortic Aneurysm in the Endovascular Era: Vigilance Remains Critical

    PubMed Central

    Bozeman, Matthew C.; Ross, Charles B.

    2012-01-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events. PMID:22454763

  5. Intra-abdominal hypertension and abdominal compartment syndrome in association with ruptured abdominal aortic aneurysm in the endovascular era: vigilance remains critical.

    PubMed

    Bozeman, Matthew C; Ross, Charles B

    2012-01-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events.

  6. Ocular Health (OH) Fundoscope Exam

    NASA Image and Video Library

    2013-06-05

    Astronaut Karen Nyberg and Astronaut Chris Cassidy (partially visible), both Expedition 37 flight engineers, perform an Ocular Health (OH) Fundoscope Exam in the Destiny laboratory of the International Space Station

  7. Observing and Deterring Social Cheating on College Exams

    ERIC Educational Resources Information Center

    Fendler, Richard J.; Yates, Michael C.; Godbey, Johnathan M.

    2018-01-01

    This research introduces a unique multiple choice exam design to observe and measure the degree to which students copy answers from their peers. Using data collected from the exam, an empirical experiment is conducted to determine whether random seat assignment deters cheating relative to a control group of students allowed to choose their seats.…

  8. Examining ethics - developing a comprehensive exam for a bioethics master's program.

    PubMed

    Schonfeld, Toby; Stoddard, Hugh; Labrecque, Cory Andrew

    2014-10-01

    Assessing mastery of bioethics in a graduate program requires careful attention not simply to the content knowledge and skill development of students but also to the principles of sound assessment processes. In this article, we describe the rationale, development process, and features of the comprehensive exam we created as a culminating experience of a master's program in bioethics. The exam became the students' opportunity to demonstrate the way they were able to integrate course, textual, and practical knowledge gained throughout the experience of the program. Additionally, the exam assessed students' proficiency in the field of bioethics and their ability to critically and constructively analyze bioethical issues. In this article, we offer tips to other exam creators regarding our experiences with question and answer development, scoring of the exam, and relationships between coursework and exam preparation and completion. We also include a sample rubric for others to see how we determined which student answers were satisfactory.

  9. Behavioral economics and diabetic eye exams.

    PubMed

    Williams, Andrew M; Liu, Peggy J; Muir, Kelly W; Waxman, Evan L

    2018-07-01

    Diabetic retinopathy is a common microvascular complication of diabetes mellitus and is the leading cause of new blindness among working-age adults in the United States. Timely intervention to prevent vision loss is possible with early detection by regular eye examinations. Unfortunately, adherence to recommended annual diabetic eye exams is poor. Public health interventions have targeted traditional barriers to care, such as cost and transportation, with limited success. Behavioral economics provides an additional framework of concepts and tools to understand low screening rates and to promote regular diabetic eye exams for populations at risk. In particular, behavioral economics outlines biases and heuristics that affect decision-making and underlie pervasive barriers to care, such as not viewing diabetic eye exams as a priority or perceiving oneself as too healthy to need an examination. In this review, we examine the literature on the use of behavioral economics interventions to promote regular diabetic eye exams. From the results of the included studies, we outline how concepts from behavioral economics can improve eye examination rates. In particular, the default bias, present bias, and self-serving bias play a significant role in precluding regular diabetic eye examinations. Potential tools to mitigate these biases include leveraging default options, using reminder messages, providing behavioral coaching, applying commitment contracts, offering financial incentives, and personalizing health messages. When combined with traditional public health campaigns, insights from behavioral economics can improve understanding of pervasive barriers to care and offer additional strategies to promote regular preventive eye care for patients with diabetes. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Performance Analysis of Exam Gloves Used for Aseptic Rodent Surgery

    PubMed Central

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-01-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP–PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham ‘exertion’ activity. According to these criteria, 94% of HP–PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP–PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries. PMID:26045458

  11. Performance analysis of exam gloves used for aseptic rodent surgery.

    PubMed

    LeMoine, Dana M; Bergdall, Valerie K; Freed, Carrie

    2015-05-01

    Aseptic technique includes the use of sterile surgical gloves for survival surgeries in rodents to minimize the incidence of infections. Exam gloves are much less expensive than are surgical gloves and may represent a cost-effective, readily available option for use in rodent surgery. This study examined the effectiveness of surface disinfection of exam gloves with 70% isopropyl alcohol or a solution of hydrogen peroxide and peracetic acid (HP-PA) in reducing bacterial contamination. Performance levels for asepsis were met when gloves were negative for bacterial contamination after surface disinfection and sham 'exertion' activity. According to these criteria, 94% of HP-PA-disinfected gloves passed, compared with 47% of alcohol-disinfected gloves. In addition, the effect of autoclaving on the integrity of exam gloves was examined, given that autoclaving is another readily available option for aseptic preparation. Performance criteria for glove integrity after autoclaving consisted of: the ability to don the gloves followed by successful simulation of wound closure and completion of stretch tests without tearing or observable defects. Using this criteria, 98% of autoclaved nitrile exam gloves and 76% of autoclaved latex exam gloves met performance expectations compared with the performance of standard surgical gloves (88% nitrile, 100% latex). The results of this study support the use of HP-PA-disinfected latex and nitrile exam gloves or autoclaved nitrile exam gloves as viable cost-effective alternatives to sterile surgical gloves for rodent surgeries.

  12. Abdominal Assessment.

    PubMed

    Fritz, Deborah; Weilitz, Pamela Becker

    2016-03-01

    Abdominal pain is one of the most common complaints by patients, and assessment of abdominal pain and associated symptoms can be challenging for home healthcare providers. Reasons for abdominal pain are related to inflammation, organ distention, and ischemia. The history and physical examination are important to narrow the source of acute or chronic problems, identify immediate interventions, and when necessary, facilitate emergency department care.

  13. Utility of ⁹⁹mTc-human serum albumin diethylenetriamine pentaacetic acid SPECT for evaluating endoleak after endovascular abdominal aortic aneurysm repair.

    PubMed

    Nakai, Motoki; Sato, Hirotatsu; Sato, Morio; Ikoma, Akira; Sonomura, Tetsuo; Nishimura, Yoshiharu; Okamura, Yoshitaka

    2015-01-01

    The purpose of this study was to assess the utility of (99m)Tc-human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) SPECT in the detection of endoleaks after endovascular abdominal aortic aneurysm repair. Fifteen patients (11 men, four women) with aneurysm sac expansion of 5 mm or greater after endovascular abdominal aortic aneurysm repair underwent three-phase CT, (99m)Tc-HSAD SPECT, and CT during aortography. Sensitivity calculations for three-phase CT and (99m)Tc-HSAD SPECT were performed with CT during aortography as the reference standard. The volume of each endoleak was measured with CT during aortography. Seven subjects underwent embolization with N-butyl cyanoacrylate (NBCA)-Lipiodol (ethiodized oil, Guerbet and metallic coils. Three-phase CT and (99m)Tc-HSAD SPECT were repeated after embolization to assess their efficacy. Endoleaks were interpreted as perigraft radioisotope accumulation in 12 patients (80.0%) on (99m)Tc-HSAD SPECT images, in 13 patients (86.7%) on three-phase CT images, and in 15 patients (100%) on CT during aortography. The mean endoleak volume visualized with (99m)Tc-HSAD SPECT was 8.37 cm(3) (range, 5.2-15.1 cm(3)), and the volume not visualized was 3.47 cm(3) (2.5-4.6 cm(3)), a statistically significant difference (p = 0.019). In two patients, (99m)Tc-HSAD SPECT depicted endoleaks evident at delayed phase CT during aortography but not at three-phase CT, suggesting they were slow-filling endoleaks. Accumulation of (99m)Tc-HSAD corresponding to endoleaks disappeared after embolization, but CT evaluation of embolization was impeded by artifacts of NBCA-Lipiodol and metallic coils. Technetium-99m-labeled HSAD SPECT proved less sensitive than three-phase CT but depicted endoleaks with volumes 5.2 cm(3) or greater as perigraft radioisotope accumulation. Slow-filling endoleaks can be visualized with (99m)Tc-HSAD SPECT, which can be used to evaluate the efficacy of embolization.

  14. Should the MCAT exam be used for medical school admissions in Canada?

    PubMed

    Eskander, Antoine; Shandling, Maureen; Hanson, Mark D

    2013-05-01

    In light of the structural and content changes to the Medical College Admission Test (MCAT) to be implemented in 2015 and the recent diversity- and social-accountability-based recommendations of the Future of Medical Education in Canada (FMEC) project, the authors review and reexamine the use of the MCAT exam in Canadian medical school admissions decisions.This Perspective article uses a point-counterpoint format to discuss three main advantages and disadvantages of using the MCAT exam in the medical school admissions process, from a Canadian perspective. The authors examine three questions regarding the FMEC recommendations and the revised MCAT exam: (1) Is the MCAT exam equal and useful in Canadian admissions? (2) Does the MCAT exam affect matriculant diversity? and (3) Is the MCAT exam a strong predictor of future performance? They present the most recent arguments and evidence for and against use of the MCAT exam, with the purpose of summarizing these different perspectives for readers.

  15. Exit Exams Face Pinch in Common-Core Push

    ERIC Educational Resources Information Center

    Ujifusa, Andrew

    2012-01-01

    With many states crafting assessments based on the common-core standards--and an increasing emphasis on college and career readiness--some are rethinking the kind of tests high school students must pass to graduate, or whether to use such exit exams at all. Twenty-five states, enrolling a total of 34.1 million students, make exit exams a…

  16. [Pathologic aerophagia: a rare cause of chronic abdominal distension].

    PubMed

    de Jesus, Lisieux Eyer; Cestari, Ana Beatriz C S S; Filho, Orli Carvalho da Silva; Fernandes, Marcia Antunes; Firme, Livia Honorato

    2015-01-01

    To describe an adolescent with pathologic aerophagia, a rare condition caused by excessive and inappropriate swallowing of air and to review its treatment and differential diagnoses. An 11 year-old mentally impaired blind girl presenting serious behavior problems and severe developmental delay with abdominal distension from the last 8 months. Her past history included a Nissen fundoplication. Abdominal CT and abdominal radiographs showed diffuse gas distension of the small bowel and colon. Hirschsprung's disease was excluded. The distention was minimal at the moment the child awoke and maximal at evening, and persisted after control of constipation. Audible repetitive and frequent movements of air swallowing were observed. The diagnosis of pathologic aerophagia associated to obsessive compulsive disorder and developmental delay was made, but pharmacological treatment was unsuccessful. The patient was submitted to an endoscopic gastrostomy, permanently opened and elevated relative to the stomach. The distention was resolved, while maintaining oral nutrition Pathologic aerophagia is a rare self-limiting condition in normal children exposed to high levels of stress and may be a persisting problem in children with psychiatric or neurologic disease. In this last group, the disease may cause serious complications. Pharmacological and behavioral treatments are ill-defined. Severe cases may demand surgical strategies, mainly decompressive gastrostomy. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  17. Abdominal Aortic Aneurysm

    MedlinePlus

    ... Kids and Teens Pregnancy and Childbirth Women Men Seniors Your Health Resources Healthcare Management End-of-Life ... familydoctor.org editorial staff Categories: Family Health, Men, Seniors, WomenTags: abdominal aorta, abdominal aortic aneurysm, abdominal pain, ...

  18. The Effects of Combined Exercise on Health-Related Fitness, Endotoxin, and Immune Function of Postmenopausal Women with Abdominal Obesity.

    PubMed

    Park, Sung-Mo; Kwak, Yi-Sub; Ji, Jin-Goo

    2015-01-01

    This study was conducted to examine the effects of combined exercise on health-related fitness, endotoxin concentrations, and immune functions of postmenopausal women with abdominal obesity. 20 voluntary participants were recruited and they were randomly allocated to the combined exercise group (n = 10) or the control group (n = 10). Visceral obesity was defined as a visceral-to-subcutaneous fat ratio ≥ 0.4 based on computed tomography (CT) results. Body composition, exercise stress testing, fitness measurement, CT scan, and blood variables were analyzed to elucidate the effects of combined exercise. The SPSS Statistics 18.0 program was used to calculate means and standard deviations for all variables. Significant differences between the exercise group and control group were determined with 2-way ANOVA and paired t-tests. The exercise group's abdominal obesity was mitigated due to visceral fat reduction; grip strength, push-ups, and oxygen uptake per weight improved; and HDL-C and IgA level also increased, while TNF-α, CD14, and endotoxin levels decreased. Lowered TNF-α after exercise might have an important role in the obesity reduction. Therefore, we can conclude that combined exercise is effective in mitigating abdominal obesity, preventing metabolic diseases, and enhancing immune function.

  19. Patient preferences for physician gender in the male genital/rectal exam.

    PubMed

    Heaton, C J; Marquez, J T

    1990-01-01

    This paper presents the results of a descriptive survey assessing male patients' past experience, current preferences, and concerns regarding the gender of the physician performing the male genital/rectal exam. The sample consists of 72 male patients seen at a university-based family practice clinic located in a small rural community in Michigan. Patient age and physician gender preference were the main independent variables of interest. This study found that 51.5% of all male patients in the sample indicated a preference for a male physician to perform the genital exam while 48.5% indicated no preference for physician gender. In contrast, for the rectal exam, 61.5% of all male patients indicated no preference for physician gender while 38.5% did express a preference for a male physician. No one expressed a preference for a female physician for either the genital or rectal exams. Further analysis revealed that male patients over the age of 40 who prefer a male physician do so, at least in part, because it would be embarrassing to have a female physician perform the exam. Few, however, would refuse to allow a female physician to perform the exam. Respondents preferred certain positions for the exam and these are a means of minimizing potential embarrassment in the older patient.

  20. Multiple-Choice and Short-Answer Exam Performance in a College Classroom

    ERIC Educational Resources Information Center

    Funk, Steven C.; Dickson, K. Laurie

    2011-01-01

    The authors experimentally investigated the effects of multiple-choice and short-answer format exam items on exam performance in a college classroom. They randomly assigned 50 students to take a 10-item short-answer pretest or posttest on two 50-item multiple-choice exams in an introduction to personality course. Students performed significantly…

  1. Analysis of patient CT dose data using virtualdose

    NASA Astrophysics Data System (ADS)

    Bennett, Richard

    X-ray computer tomography has many benefits to medical and research applications. Recently, over the last decade CT has had a large increase in usage in hospitals and medical diagnosis. In pediatric care, from 2000 to 2006, abdominal CT scans increased by 49 % and chest CT by 425 % in the emergency room (Broder 2007). Enormous amounts of effort have been performed across multiple academic and government groups to determine an accurate measure of organ dose to patients who undergo a CT scan due to the inherent risks with ionizing radiation. Considering these intrinsic risks, CT dose estimating software becomes a necessary tool that health care providers and radiologist must use to determine many metrics to base the risks versus rewards of having an x-ray CT scan. This thesis models the resultant organ dose as body mass increases for patients with all other related scan parameters fixed. In addition to this,this thesis compares a modern dose estimating software, VirtualDose CT to two other programs, CT-Expo and ImPACT CT. The comparison shows how the software's theoretical basis and the phantom they use to represent the human body affect the range of results in organ dose. CT-Expo and ImPACT CT dose estimating software uses a different model for anatomical representation of the organs in the human body and the results show how that approach dramatically changes the outcome. The results categorizes four datasets as compared to the three software types where the appropriate phantom was available. Modeling was done to simulate chest abdominal pelvis scans and whole body scans. Organ dose difference versus body mass index shows as body mass index (BMI) ranges from 23.5 kg/m 2 to 45 kg/m2 the amount of organ dose also trends a percent change from -4.58 to -176.19 %. Comparing organ dose difference with increasing x-ray tube potential from 120 kVp to 140 kVp the percent change in organ dose increases from 55 % to 65 % across all phantoms. In comparing VirtualDose to CT

  2. SU-E-J-208: Fast and Accurate Auto-Segmentation of Abdominal Organs at Risk for Online Adaptive Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, V; Wang, Y; Romero, A

    2014-06-01

    Purpose: Various studies have demonstrated that online adaptive radiotherapy by real-time re-optimization of the treatment plan can improve organs-at-risk (OARs) sparing in the abdominal region. Its clinical implementation, however, requires fast and accurate auto-segmentation of OARs in CT scans acquired just before each treatment fraction. Autosegmentation is particularly challenging in the abdominal region due to the frequently observed large deformations. We present a clinical validation of a new auto-segmentation method that uses fully automated non-rigid registration for propagating abdominal OAR contours from planning to daily treatment CT scans. Methods: OARs were manually contoured by an expert panel to obtain groundmore » truth contours for repeat CT scans (3 per patient) of 10 patients. For the non-rigid alignment, we used a new non-rigid registration method that estimates the deformation field by optimizing local normalized correlation coefficient with smoothness regularization. This field was used to propagate planning contours to repeat CTs. To quantify the performance of the auto-segmentation, we compared the propagated and ground truth contours using two widely used metrics- Dice coefficient (Dc) and Hausdorff distance (Hd). The proposed method was benchmarked against translation and rigid alignment based auto-segmentation. Results: For all organs, the auto-segmentation performed better than the baseline (translation) with an average processing time of 15 s per fraction CT. The overall improvements ranged from 2% (heart) to 32% (pancreas) in Dc, and 27% (heart) to 62% (spinal cord) in Hd. For liver, kidneys, gall bladder, stomach, spinal cord and heart, Dc above 0.85 was achieved. Duodenum and pancreas were the most challenging organs with both showing relatively larger spreads and medians of 0.79 and 2.1 mm for Dc and Hd, respectively. Conclusion: Based on the achieved accuracy and computational time we conclude that the investigated auto

  3. SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeh, M; Wang, Y; Weng, H

    Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. Formore » computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.« less

  4. Hispanic Student Performance on Advanced Placement Exams: A Multiyear, National Investigation

    ERIC Educational Resources Information Center

    Jara, Teresa Dianne

    2013-01-01

    Purpose: The purpose of this study was to analyze the Advanced Placement exams that Hispanic students complete and to compare their overall performance with the performance of White students from 2000 to 2012. A second purpose was to determine which Advanced Placement exams were the most difficult exams for Hispanic students and which Advanced…

  5. Assessing Conceptual and Algorithmic Knowledge in General Chemistry with ACS Exams

    ERIC Educational Resources Information Center

    Holme, Thomas; Murphy, Kristen

    2011-01-01

    In 2005, the ACS Examinations Institute released an exam for first-term general chemistry in which items are intentionally paired with one conceptual and one traditional item. A second-term, paired-questions exam was released in 2007. This paper presents an empirical study of student performances on these two exams based on national samples of…

  6. Relationships between Preclinical Course Grades and Standardized Exam Performance

    ERIC Educational Resources Information Center

    Hu, Yinin; Martindale, James R.; LeGallo, Robin D.; White, Casey B.; McGahren, Eugene D.; Schroen, Anneke T.

    2016-01-01

    Success in residency matching is largely contingent upon standardized exam scores. Identifying predictors of standardized exam performance could promote primary intervention and lead to design insights for preclinical courses. We hypothesized that clinically relevant courses with an emphasis on higher-order cognitive understanding are most…

  7. Expedition 50 Qualification Exams

    NASA Image and Video Library

    2016-10-25

    Expedition 50 crew members NASA astronaut Peggy Whitson, left, Russian cosmonaut Oleg Novitskiy of Roscosmos, center, and ESA astronaut Thomas Pesquet laugh together as they prepare for their final qualification exams, Tuesday, Oct. 25, 2016, at the Gagarin Cosmonaut Training Center (GCTC) in Star City, Russia. Photo Credit: (NASA/Bill Ingalls)

  8. Developing a prelicensure exam for Canada: an international collaboration.

    PubMed

    Hobbins, Bonnie; Bradley, Pat

    2013-01-01

    Nine previously conducted studies indicate that Elsevier's HESI Exit Exam (E(2)) is 96.36%-99.16% accurate in predicting success on the National Council Licensure Examination for Registered Nurses. No similar standardized exam is available in Canada to predict Canadian Registered Nurse Examination (CRNE) success. Like the E(2), such an exam could be used to evaluate Canadian nursing students' preparedness for the CRNE, and scores on the numerous subject matter categories could be used to guide students' remediation efforts so that, ultimately, they are successful on their first attempt at taking the CRNE. The international collaboration between a HESI test construction expert and a nursing faculty member from Canada, who served as the content expert, resulted in the development of a 180-item, multiple-choice/single-answer prelicensure exam (PLE) that was pilot tested with Canadian nursing students (N = 175). Item analysis data obtained from this pilot testing were used to develop a 160-item PLE, which includes an additional 20 pilot test items. The estimated reliability of this exam is 0.91, and it exhibits congruent validity with the CRNE because the PLE test blueprint mimics the CRNE test blueprint. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Intra-abdominal hypertension and abdominal compartment syndrome in pediatrics. A review.

    PubMed

    Thabet, Farah Chedly; Ejike, Janeth Chiaka

    2017-10-01

    To consolidate pediatric intensivists' understanding of the pathophysiology, definition, incidence, monitoring, and management of intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS); and to highlight the characteristics related to the pediatric population. This is a narrative review article that utilized a systematic search of the medical literature published in the English language between January 1990 and august 2016. Studies were identified by conducting a comprehensive search of Pub Med databases. Search terms included "intra-abdominal hypertension and child", "intra-abdominal hypertension and pediatrics", "abdominal compartment syndrome and child", and "abdominal compartment syndrome and pediatrics". Intra-abdominal hypertension and ACS are associated with a number of pathophysiological disturbances and increased morbidity and mortality. These conditions have been well described in critically ill adults. In children, the IAH and the ACS have a reported incidence of 13% and 0.6 to 10% respectively; they carry similar prognostic impact but are still under-diagnosed and under-recognized by pediatric health care providers. Intra-abdominal hypertension and ACS are conditions that are regularly encountered in critically ill children. They are associated with an increased morbidity and mortality. Early recognition, prevention and timely management of this critical condition are necessary to improve its outcome. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Assessment of image quality and low-contrast detectability in abdominal CT of obese patients: comparison of a novel integrated circuit with a conventional discrete circuit detector at different tube voltages.

    PubMed

    Euler, A; Heye, T; Kekelidze, M; Bongartz, G; Szucs-Farkas, Z; Sommer, C; Schmidt, B; Schindera, Sebastian T

    2015-03-01

    To compare image quality and low-contrast detectability of an integrated circuit (IC) detector in abdominal CT of obese patients with conventional detector technology at low tube voltages. A liver phantom with 45 lesions was placed in a water container to mimic an obese patient and examined on two different CT systems at 80, 100 and 120 kVp. The systems were equipped with either the IC or conventional detector. Image noise was measured, and the contrast-to-noise-ratio (CNR) was calculated. Low-contrast detectability was assessed independently by three radiologists. Radiation dose was estimated by the volume CT dose index (CTDIvol). The image noise was significantly lower, and the CNR was significantly higher with the IC detector at 80, 100 and 120 kVp, respectively (P = 0.023). The IC detector resulted in an increased lesion detection rate at 80 kVp (38.1 % vs. 17.2 %) and 100 kVp (57.0 % vs. 41.0 %). There was no difference in the detection rate between the IC detector at 100 kVp and the conventional detector at 120 kVp (57.0 % vs. 62.2 %). The CTDIvol at 80, 100 and 120 kVp measured 4.5-5.2, 7.3-7.9 and 9.8-10.2 mGy, respectively. The IC detector at 100 kVp resulted in similar low-contrast detectability compared to the conventional detector with a 120-kVp protocol at a radiation dose reduction of 37 %.

  11. Plain abdominal radiography in acute abdominal pain; past, present, and future

    PubMed Central

    Gans, Sarah L; Stoker, Jaap; Boermeester, Marja A

    2012-01-01

    Several studies have demonstrated that a diagnosis based solely on a patient’s medical history, physical examination, and laboratory tests is not reliable enough, despite the fact that these aspects are essential parts of the workup of a patient presenting with acute abdominal pain. Traditionally, imaging workup starts with abdominal radiography. However, numerous studies have demonstrated low sensitivity and accuracy for plain abdominal radiography in the evaluation of acute abdominal pain as well as various specific diseases such as perforated viscus, bowel obstruction, ingested foreign body, and ureteral stones. Computed tomography, and in particular computed tomography after negative ultrasonography, provides a better workup than plain abdominal radiography alone. The benefits of computed tomography lie in decision-making for management, planning of a surgical strategy, and possibly even avoidance of negative laparotomies. Based on abundant available evidence, major advances in diagnostic imaging, and changes in the management of certain diseases, we can conclude that there is no place for plain abdominal radiography in the workup of adult patients with acute abdominal pain presenting in the emergency department in current practice. PMID:22807640

  12. Radiographic evaluation of nasal septal deviation from computed tomography correlates poorly with physical exam findings.

    PubMed

    Sedaghat, Ahmad R; Kieff, David A; Bergmark, Regan W; Cunnane, Mary E; Busaba, Nicolas Y

    2015-03-01

    Performance of septoplasty is dependent on objective evidence of nasal septal deviation. Although physical examination including anterior rhinoscopy and endoscopic examination is the gold standard for evaluation of septal deviation, third-party payors' reviews of septoplasty claims are often made on computed tomography (CT) findings. However, the correlation between radiographic evaluation of septal deviation with physical examination findings is unknown. Retrospective, blinded, independent evaluation of septal deviation in 39 consecutive patients from physical examination, including anterior rhinoscopy and endoscopic examination, by an otolaryngologist and radiographic evaluation of sinus CT scan by a neuroradiologist. Four distinct septal locations (nasal valve, cartilaginous, inferior/maxillary crest and osseous septum) were evaluated on a 4-point scale representing (1) 0% to 25%, (2) >25% to 50%, (3) >50% to 75%, and (4) >75% obstruction. Correlation between physical examination and radiographic evaluations was made by Pearson's correlation and quantitative agreement assessed by Krippendorf's alpha. Statistically significant correlation was detected between physical examination including nasal endoscopy and radiographic assessment of septal deviation only at the osseous septum (p = 0.007, r = 0.425) with low quantitative agreement (α = 0.290). No significant correlation was detected at the cartilaginous septum (p = 0.286, r = 0.175), inferior septum (p = 0.117, r = 0.255), or nasal valve (p = 0.174, r = 0.222). Quantitative agreement at the nasal valve suggested a bias in CT to underestimate physical exam findings (α = -0.490). CT is a poor substitute for physical examination, the gold standard, in assessment of septal deviation. Clinical decisions about pursuit of septoplasty or third-party payors' decisions to approve septoplasty should not be made on radiographic evidence. © 2014 ARS-AAOA, LLC.

  13. An unusual cause of paediatric abdominal pain: Mesenteric masses accompanied with volvulus.

    PubMed

    Yang, Chao; Wang, Shan; Zhang, Jun; Kong, Xiang Ru; Zhao, Zhenzhen; Li, Chang Chun

    2016-07-01

    Volvulus caused by mesenteric masses is rare and may result in serious consequences. This study aimed to better characterize volvulus caused by mesenteric masses in children. A retrospective study was conducted in 24 patients who underwent surgical treatment between January 1994 and January 2014 in one single institution. There were 10 boys and 14 girls. The most frequent findings were abdominal pain (100%), emesis (91.7%) and nausea (83.3%). Physical examination showed positive ileus signs in majority cases, and palpable mass was found in half of the patients. Ultrasound and CT scans revealed mesenteric masses in 21 and 24 patients, and 'whirlpool sign' was observed in 19 and 22 patients, respectively. Emergency laparotomy was performed in all patients. Histological examination revealed that 18 cystic masses were lymphangioma, 5 solid cases were lipoma and the remaining one was lipoblastoma. The postoperative course was uneventful in 22 patients, and postoperative obstruction and incision infection occurred in 2 patients. There was no evidence of recurrence at follow-up. Volvulus caused by mesenteric masses is a rare but potentially life-threatening cause of abdominal pain, which should be considered in the differential diagnosis of paediatric acute abdominal pain.

  14. The Preparatory Workshop: A Partial Solution to an English Compulsory Exam Failure Rate.

    ERIC Educational Resources Information Center

    Naugle, Helen; McGuire, Peter

    Georgia Institute of Technology has created a preparatory workshop that avoids focusing composition courses on the state competency exam while helping its students pass the exam. In checking the exams of students who had failed, three problems appeared: lack of motivation, lack of awareness of the standards for grading the exam, and an inability…

  15. Applying a deep learning based CAD scheme to segment and quantify visceral and subcutaneous fat areas from CT images

    NASA Astrophysics Data System (ADS)

    Wang, Yunzhi; Qiu, Yuchen; Thai, Theresa; Moore, Kathleen; Liu, Hong; Zheng, Bin

    2017-03-01

    Abdominal obesity is strongly associated with a number of diseases and accurately assessment of subtypes of adipose tissue volume plays a significant role in predicting disease risk, diagnosis and prognosis. The objective of this study is to develop and evaluate a new computer-aided detection (CAD) scheme based on deep learning models to automatically segment subcutaneous fat areas (SFA) and visceral (VFA) fat areas depicting on CT images. A dataset involving CT images from 40 patients were retrospectively collected and equally divided into two independent groups (i.e. training and testing group). The new CAD scheme consisted of two sequential convolutional neural networks (CNNs) namely, Selection-CNN and Segmentation-CNN. Selection-CNN was trained using 2,240 CT slices to automatically select CT slices belonging to abdomen areas and SegmentationCNN was trained using 84,000 fat-pixel patches to classify fat-pixels as belonging to SFA or VFA. Then, data from the testing group was used to evaluate the performance of the optimized CAD scheme. Comparing to manually labelled results, the classification accuracy of CT slices selection generated by Selection-CNN yielded 95.8%, while the accuracy of fat pixel segmentation using Segmentation-CNN yielded 96.8%. Therefore, this study demonstrated the feasibility of using deep learning based CAD scheme to recognize human abdominal section from CT scans and segment SFA and VFA from CT slices with high agreement compared with subjective segmentation results.

  16. Management of complex abdominal wall defects associated with penetrating abdominal trauma.

    PubMed

    Arul, G Suren; Sonka, B J; Lundy, J B; Rickard, R F; Jeffery, S L A

    2015-03-01

    The paradigm of Damage Control Surgery (DCS) has radically improved the management of abdominal trauma, but less well described are the options for managing the abdominal wall itself in an austere environment. This article describes a series of patients with complex abdominal wall problems managed at the UK-led Role 3 Medical Treatment Facility (MTF) in Camp Bastion, Afghanistan. Contemporaneous review of a series of patients with complex abdominal wall injuries who presented to the Role 3 MTF between July and November 2012. Five patients with penetrating abdominal trauma associated with significant damage to the abdominal wall were included. All patients were managed using DCS principles, leaving the abdominal wall open at the end of the first procedure. Subsequent management of the abdominal wall was determined by a multidisciplinary team of general and plastic surgeons, intensivists and specialist nurses. The principles of management identified included minimising tissue loss on initial laparotomy by joining adjacent wounds and marginal debridement of dead tissue; contraction of the abdominal wall was minimised by using topical negative pressure dressing and dermal-holding sutures. Definitive closure was timed to allow oedema to settle and sepsis to be controlled. Closure techniques include delayed primary closure with traction sutures, components separation, and mesh closure with skin grafting. A daily multidisciplinary team discussion was invaluable for optimal decision making regarding the most appropriate means of abdominal closure. Dermal-holding sutures were particularly useful in preventing myostatic contraction of the abdominal wall. A simple flow chart was developed to aid decision making in these patients. This flow chart may prove especially useful in a resource-limited environment in which returning months or years later for closure of a large ventral hernia may not be possible. Published by the BMJ Publishing Group Limited. For permission to use

  17. Washback Effect of University Entrance exams in Applied Mathematics to Social Sciences.

    PubMed

    Rodríguez-Muñiz, Luis J; Díaz, Patricia; Mier, Verónica; Alonso, Pedro

    2016-01-01

    Curricular issues of subject Applied Mathematics to Social Sciences are studied in relation to university entrance exams performed in several Spanish regions between 2009-2014. By using quantitative and qualitative analyses, it has been studied how these exams align with curriculum and how they produce a washback on curriculum and teachers' work. Additionally, one questionnaire about teachers' practices has been performed, in order to find out how the exams are influencing teaching methodology development. Main results obtained show that evaluation is producing a bias on the official curriculum, substantially simplifying the specific orientation that should guide applied mathematics. Furthermore, teachers' practices are influenced by the exams, and they usually approach their teaching methodology to the frequent types of exams. Also, slight differences among the teachers lead to distinguish two behavioral subgroups. Results can also be useful in an international context, because of the importance of standardized exit exams in OECD countries.

  18. Pediatric FAST and elevated liver transaminases: An effective screening tool in blunt abdominal trauma.

    PubMed

    Sola, Juan E; Cheung, Michael C; Yang, Relin; Koslow, Starr; Lanuti, Emma; Seaver, Chris; Neville, Holly L; Schulman, Carl I

    2009-11-01

    The current standard for the evaluation of children with blunt abdominal trauma (BAT) consists of physical examination, screening lab values, and computed tomography (CT) scan. We sought to determine if the focused assessment with sonography for trauma (FAST) combined with elevated liver transaminases (AST/ALT) could be used as a screening tool for intra-abdominal injury (IAI) in pediatric patients with BAT. Registry data at a level 1 trauma center was retrospectively reviewed from 1991-2007. Data collected on BAT patients under the age of 16 y included demographics, injury mechanism, ISS, GCS, imaging studies, serum ALT and AST levels, and disposition. AST and ALT were considered positive if either one was >100 IU/L. Overall, 3171 cases were identified. A total of 1008 (31.8%) patients received CT scan, 1148 (36.2%) had FAST, and 497 (15.7%) patients received both. Of the 497 patients, 400 (87.1%) also had AST and ALT measured. FAST was 50% sensitive, 91% specific, with a positive predictive value (PPV) of 68%, negative predictive value (NPV) of 83%, and accuracy of 80%. Combining FAST with elevated AST or ALT resulted in a statistically significant increase in all measures (sensitivity 88%, specificity 98%, PPV 94%, NPV 96%, accuracy 96%). FAST combined with AST or ALT > 100 IU/L is an effective screening tool for IAI in children following BAT. Pediatric patients with a negative FAST and liver transaminases < 100 IU/L should be observed rather than subjected to the radiation risk of CT.

  19. The Value of Lung Cancer CT Screening: It Is All about Implementation.

    PubMed

    Goulart, Bernardo H L

    2015-01-01

    Hospitals have been gradually implementing new lung cancer CT screening programs following the release of the U.S. Preventive Services Task Force grade B recommendation to screen individuals at high risk for lung cancer. Policy makers have legitimately questioned whether adoption of CT screening in the community will reproduce the mortality benefits seen in the National Lung Screening Trial (NLST) and whether the benefits of screening will justify the potentially high costs. Although three annual CT screening exams proved cost-effective for the patient population enrolled in the NLST, uncertainty still exists about whether CT screening will be cost-effective in practice. The value of CT screening will depend largely on the strategies used to implement it. This manuscript reviews the current reimbursement policies for CT screening and explains the relationship between implementation strategies and screening value on the basis of the NLST cost-effectiveness analysis and other published data. A subsequent discussion ensues about the potential implementation inefficiencies that can negatively affect the value of CT screening (e.g., selection of low-risk individuals for screening, inappropriate follow-up visits for screening-detected lung nodules, failure to offer smoking cessation interventions, and overuse of medical resources for clinically irrelevant incidental findings) and the actions that can be taken to mitigate these inefficiencies and increase the value of screening.

  20. Peer-led instruction for a qualifying exam preparatory course or: How I learned to stop worrying and love the PhD Qualifying Exam

    NASA Astrophysics Data System (ADS)

    Christensen, Warren; Engelhardt, Larry

    2006-04-01

    In the spring of 2004, the authors were charged with the task of creating and administering a qualifying exam preparation curriculum that would strive to assist graduate students studying for their comprehensive physics exam. We incorporated many pedagogical techniques that have been proven effective at nearly all levels of instruction by leading researchers in the field of physics education. Our primary focus was on peer-led instruction and time-on-task doing actual problems from previous qualifying exams. After a brief but precise lecture covering essential ideas over a particular subject matter, students spend most of class time working in small groups and presenting worked problems at the board. At all times, the focus was on student explanations concerning the fundamental concepts behind a specific problem, as well as contemplating variations to broaden understanding and challenge students to think on their feet. We found that students who attended and participated regularly in class could be correlated with those students who achieved high marks on the exam.

  1. The value of plain abdominal radiographs in management of abdominal emergencies in Luth.

    PubMed

    Ashindoitiang, J A; Atoyebi, A O; Arogundade, R A

    2008-01-01

    The plain abdominal x-ray is still the first imaging modality in diagnosis of acute abdomen. The aim of this study was to find the value of plain abdominal x-ray in the management of abdominal emergencies seen in Lagos university teaching hospital. The accurate diagnosis of the cause of acute abdominal pain is one of the most challenging undertakings in emergency medicine. This is due to overlapping of clinical presentation and non-specific findings of physical and even laboratory data of the multifarious causes. Plain abdominal radiography is one investigation that can be obtained readily and within a short period of time to help the physician arrive at a correct diagnosis The relevance of plain abdominal radiography was therefore evaluated in the management of abdominal emergencies seen in Lagos over a 12 month period (April 2002 to March 2003). A prospective study of 100 consecutively presenting patients with acute abdominal conditions treated by the general surgical unit of Lagos University Teaching Hospital was undertaken. All patients had supine and erect abdominal x-ray before any therapeutic intervention was undertaken. The diagnostic features of the plain films were compared with final diagnosis to determine the usefulness of the plain x-ray There were 54 males and 46 females (M:F 1.2:1). Twenty-four percent of the patients had intestinal obstruction, 20% perforated typhoid enteritis; gunshot injuries and generalized peritonitis each occurred in 13%, blunt abdominal trauma in 12%, while 8% and 10% had acute appendicitis and perforated peptic ulcer disease respectively. Of 100 patients studied, 54% had plain abdominal radiographs that showed positive diagnostic features. Plain abdominal radiograph showed high sensitivity in patients with intestinal obstruction 100% and perforated peptic ulcer 90% but was less sensitive in patients with perforated typhoid, acute appendicitis, and blunt abdominal trauma and generalized peritonitis. In conclusion, this study

  2. Evaluation of the levels of metalloproteinsase-2 in patients with abdominal aneurysm and abdominal hernias.

    PubMed

    Antoszewska, Magdalena

    2013-05-01

    Abdominal aortic aneurysms and abdominal hernias become an important health problems of our times. Abdominal aortic aneurysm and its rupture is one of the most dangerous fact in vascular surgery. There are some theories pointing to a multifactoral genesis of these kinds of diseases, all of them assume the attenuation of abdominal fascia and abdominal aortic wall. The density and continuity of these structures depend on collagen and elastic fibers structure. Reducing the strength of the fibers may be due to changes in the extracellular matrix (ECM) by the proteolytic enzymes-matrix metalloproteinases (MMPs) that degrade extracellular matrix proteins. These enzymes play an important role in the development of many disease: malignant tumors (colon, breast, lung, pancreas), cardiovascular disease (myocardial infarction, ischemia-reperfusion injury), connective tissue diseases (Ehler-Danlos Syndrome, Marfan's Syndrome), complications of diabetes (retinopathy, nephropathy). One of the most important is matrix metalloproteinase-2 (MMP-2). The aim of the study was an estimation of the MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia, and in patients with only abdominal aortic aneurysm. The study involved 88 patients aged 42 to 89 years, including 75 men and 13 women. Patients were divided into two groups: patients with abdominal aortic aneurysm and primary abdominal hernia (45 persons, representing 51.1% of all group) and patients with only abdominal aortic aneurysm (43 persons, representing 48,9% of all group). It was a statistically significant increase in MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia compared to patients with only abdominal aortic aneurysm. It was a statistically significant increase in the prevalence of POCHP in patients with only abdominal aortic aneurysm compared to patients with abdominal aortic aneurysm and primary abdominal hernia. Statistically significant

  3. Atypical moyamoya syndrome with brain calcification and stenosis of abdominal aorta and renal arteries.

    PubMed

    Uchikawa, Hideki; Fujii, Katsunori; Fujita, Mayuko; Okunushi, Tomoko; Shimojo, Naoki

    2017-09-01

    Moyamoya syndrome is a progressive cerebrovascular disease that is characterized by stenosis of the terminal portion of the internal carotid artery and its main branches, in combination with an accompanying disease. We herein describe an 8-year-old boy exhibiting transient loss of consciousness, who had recurrent seizures in infancy with progressive brain calcification. On admission, he was alert but magnetic resonance angiography showed bilateral stenosis of the whole internal carotid artery and proliferation of vascular collaterals, and brain CT revealed calcification on bilateral putamen. Given that this fulfilled diagnostic criteria, we finally diagnosed him as having moyamoya syndrome, though the etiology was unclear. Interestingly, a whole vessel survey revealed vascular stenosis of abdominal aorta and renal arteries, in which the former has not been reported in moyamoya syndrome. We considered that brain calcification was gradually formed by decreased cerebral vascular flow from infancy, and stenosis of abdominal aorta was possibly extended from renal arteries. This is, moyamoya syndrome with brain calcification and stenosis of abdominal aorta, suggesting that morphological screening of whole vessels containing cerebral and abdominal arteries should be considered in cases of slowly progressive brain calcification. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  4. Redesigning the MCAT exam: balancing multiple perspectives.

    PubMed

    Schwartzstein, Richard M; Rosenfeld, Gary C; Hilborn, Robert; Oyewole, Saundra Herndon; Mitchell, Karen

    2013-05-01

    The authors of this commentary discuss the recently completed review of the current Medical College Admission Test (MCAT), which has been used since 1991, and describe the blueprint for the new test that will be introduced in 2015. The design of the MCAT exam reflects changes in medical education, medical science, health care delivery, and the needs of the populations served by graduates of U.S. and Canadian medical schools. The authors describe how balancing the ambitious goals for the new exam and the varying priorities of the testing program's many stakeholders made blueprint design complex. They discuss the tensions and trade-offs that characterized the design process as well as the deliberations and data that shaped the blueprint.The blueprint for the MCAT exam balances the assessment of a broad range of competencies in the natural, social, and behavioral sciences and critical analysis and reasoning skills that are essential to entering students' success in medical school. The exam will include four sections: Biological and Biochemical Foundations of Living Systems; Chemical and Physical Foundations of Biological Systems; Psychological, Social, and Biological Foundations of Behavior; and Critical Analysis and Reasoning Skills.The authors also offer recommendations for admission committees, advising them to review applicants' test scores, course work, and other academic, personal, and experiential credentials as part of a holistic admission process and in relation to their institutions' educational, scientific, clinical, and service-oriented goals.

  5. Investigating the Variables in a Mock Exam Study Session Designed to Improve Student Exam Performance in an Undergraduate Behavior Modification and Therapy Course

    ERIC Educational Resources Information Center

    Dotson, Wesley H.

    2010-01-01

    The purpose of the present study was to identify components of an optional mock exam review session (e.g. requiring students to write answers, providing students grading keys for questions) responsible for improvements in student performance on application-based short-essay exams in an undergraduate behavior modification course. Both…

  6. [A commonly seen cause of abdominal pain: abdominal cutaneous nerve entrapment syndrome].

    PubMed

    Solmaz, Ilker; Talay, Mustafa; Tekindur, Şükrü; Kurt, Ercan

    2012-01-01

    Although abdominal cutaneous nerve entrapment syndrome (ACNES) is accepted as a rare condition, it is a syndrome that should be diagnosed more commonly when the clinical signs cannot explain the cause of abdominal pain. Abdominal pain is commonly considered by physicians to be based on intra-abdominal causes. Consequently, redundant tests and consultations are requested for these patients, and unnecessary surgical procedures may be applied. Patients with this type of pain are consulted to many clinics, and because their definitive diagnoses cannot be achieved, they are assessed as psychiatric patients. Actually, a common cause of abdominal wall pain is nerve entrapment on the lateral edge of the rectus abdominis muscle. In this paper, we would like to share information about the diagnosis and treatment of a patient who, prior to presenting to us, had applied to different clinics for chronic abdominal pain and had undergone many tests and consultations; abdominal surgery was eventually decided.

  7. Reduced dose CT with model-based iterative reconstruction compared to standard dose CT of the chest, abdomen, and pelvis in oncology patients: intra-individual comparison study on image quality and lesion conspicuity.

    PubMed

    Morimoto, Linda Nayeli; Kamaya, Aya; Boulay-Coletta, Isabelle; Fleischmann, Dominik; Molvin, Lior; Tian, Lu; Fisher, George; Wang, Jia; Willmann, Jürgen K

    2017-09-01

    To compare image quality and lesion conspicuity of reduced dose (RD) CT with model-based iterative reconstruction (MBIR) compared to standard dose (SD) CT in patients undergoing oncological follow-up imaging. Forty-four cancer patients who had a staging SD CT within 12 months were prospectively included to undergo a weight-based RD CT with MBIR. Radiation dose was recorded and tissue attenuation and image noise of four tissue types were measured. Reproducibility of target lesion size measurements of up to 5 target lesions per patient were analyzed. Subjective image quality was evaluated for three readers independently utilizing 4- or 5-point Likert scales. Median radiation dose reduction was 46% using RD CT (P < 0.01). Median image noise across all measured tissue types was lower (P < 0.01) in RD CT. Subjective image quality for RD CT was higher (P < 0.01) in regard to image noise and overall image quality; however, there was no statistically significant difference regarding image sharpness (P = 0.59). There were subjectively more artifacts on RD CT (P < 0.01). Lesion conspicuity was subjectively better in RD CT (P < 0.01). Repeated target lesion size measurements were highly reproducible both on SD CT (ICC = 0.987) and RD CT (ICC = 0.97). RD CT imaging with MBIR provides diagnostic imaging quality and comparable lesion conspicuity on follow-up exams while allowing dose reduction by a median of 46% compared to SD CT imaging.

  8. Washback Effect of University Entrance exams in Applied Mathematics to Social Sciences

    PubMed Central

    Díaz, Patricia; Mier, Verónica; Alonso, Pedro

    2016-01-01

    Curricular issues of subject Applied Mathematics to Social Sciences are studied in relation to university entrance exams performed in several Spanish regions between 2009–2014. By using quantitative and qualitative analyses, it has been studied how these exams align with curriculum and how they produce a washback on curriculum and teachers’ work. Additionally, one questionnaire about teachers’ practices has been performed, in order to find out how the exams are influencing teaching methodology development. Main results obtained show that evaluation is producing a bias on the official curriculum, substantially simplifying the specific orientation that should guide applied mathematics. Furthermore, teachers’ practices are influenced by the exams, and they usually approach their teaching methodology to the frequent types of exams. Also, slight differences among the teachers lead to distinguish two behavioral subgroups. Results can also be useful in an international context, because of the importance of standardized exit exams in OECD countries. PMID:27936103

  9. [Mobile CT: technical aspects of prehospital stroke imaging before intravenous thrombolysis].

    PubMed

    Gierhake, D; Weber, J E; Villringer, K; Ebinger, M; Audebert, H J; Fiebach, J B

    2013-01-01

    To reduce the time from symptom onset to treatment with tissue plasminogen activator (tPA) in ischemic stroke, an ambulance was equipped with a CT scanner. We analyzed process and image quality of CT scanning during the pilot study regarding image quality and safety issues. The pilot study of a stroke emergency mobile unit (STEMO) ran over a period of 12 weeks on 5 weekdays from 7a.m. to 6:30 p.m. A teleradiological service for the justifying indication and reporting was established. The radiographer was responsible for the performance of the CT scan on the ambulance. 64 cranial CT scans and 1 intracranial CT angiography were performed. We compared times from ambulance alarm to treatment decision (time of last brain scan) with a cohort of 50 consecutive tPA treatments before implementation of STEMO. 62 (95%) of the 65 scans performed had sufficient quality for reading. Technical quality was not optimal in 45 cases (69%) mainly caused by suboptimal positioning of patient or eye lens protection. Motion artefacts were observed in 8 exams (12%). No safety issues occurred for team or patients. 23 patients were treated with thrombolysis. Time from alarm to last CT scan was 18 minutes shorter than in the tPA cohort before STEMO implementation. A teleradiological support for primary stroke imaging by CT on-site is feasible, quality-wise of diagnostic value and has not raised safety issues. © Georg Thieme Verlag KG Stuttgart · New York.

  10. EFL Teachers' Formal Assessment Practices Based on Exam Papers

    ERIC Educational Resources Information Center

    Kiliçkaya, Ferit

    2016-01-01

    This study reports initial findings from a small-scale qualitative study aimed at gaining insights into English language teachers' assessment practices in Turkey by examining the formal exam papers. Based on the technique of content analysis, formal exam papers were analyzed in terms of assessment items, language skills tested as well as the…

  11. Investigation of iterative image reconstruction in low-dose breast CT

    NASA Astrophysics Data System (ADS)

    Bian, Junguo; Yang, Kai; Boone, John M.; Han, Xiao; Sidky, Emil Y.; Pan, Xiaochuan

    2014-06-01

    There is interest in developing computed tomography (CT) dedicated to breast-cancer imaging. Because breast tissues are radiation-sensitive, the total radiation exposure in a breast-CT scan is kept low, often comparable to a typical two-view mammography exam, thus resulting in a challenging low-dose-data-reconstruction problem. In recent years, evidence has been found that suggests that iterative reconstruction may yield images of improved quality from low-dose data. In this work, based upon the constrained image total-variation minimization program and its numerical solver, i.e., the adaptive steepest descent-projection onto the convex set (ASD-POCS), we investigate and evaluate iterative image reconstructions from low-dose breast-CT data of patients, with a focus on identifying and determining key reconstruction parameters, devising surrogate utility metrics for characterizing reconstruction quality, and tailoring the program and ASD-POCS to the specific reconstruction task under consideration. The ASD-POCS reconstructions appear to outperform the corresponding clinical FDK reconstructions, in terms of subjective visualization and surrogate utility metrics.

  12. [Preoperative CT angiography for planning free perforator flaps in breast reconstruction].

    PubMed

    Kuekrek, H; Müller, D; Paepke, S; Dobritz, M; Machens, H-G; Giunta, R E

    2011-04-01

    Preoperative Doppler ultrasonography for planning free perforator flaps is widely established to identify preoperatively perforators. The method allows one to localise the penetrating point of the perforator through the abdominal fascia. By this means it is not possible to see the intramuscular course or the position of the perforator in relation to the inferior epigastric artery. Lately the technique of computed tomographic angiography provides an opportunity for visualising the course of perforator vessels in these tissues. This paper summarises our experience with the preoperative CT angiography in our breast centre. Since spring 2009 we have reconstructed the breasts of 44 female patients by using free flaps from the lower abdominal wall. 6 of these were bilateral. In a total number of 50 breast reconstructions we used 23 deep inferior epigastric perforator (DIEP) flaps and 27 muscle-sparing transverse rectus abdominis muscle (TRAM) flaps. In addition to the preoperative ultrasonography, a CT angiography of the lower abdomen was conducted in 29 patients. On average they showed at least 2 perforators on the left as well as right abdominal sides, which could be used as flap vessels based on their signal intensity. Based on their estimated microsurgical dissection complexity, the perforator vessels could be classified into 3 groups: 1) direct perforators of category A with short intramuscular course (39%), 2) perforators with long intramuscular course of category B (50%) and 3) "turn around" perforators of category C, which pass medially around the rectus abdominis (11%). The technique of CT angiography permits a reliable preoperative visualisation of perforators in their entire course and facilitates the selection of the supplying perforator as well as the intraoperative procedure for the surgeon. The suggested classification of perforators into 3 groups simplifies the preoperative assessment of the microsurgical dissection effort. Compared to the commonly used

  13. [What happens when medical students set their own exam papers?].

    PubMed

    Baerheim, A; Meland, E

    2001-10-20

    In the section for general practice at the University of Bergen, Norway, we want to emphasise learning more than control in our work with students. As a step in this direction we invited students to come up with proposals for exam papers, papers that usually include six to nine multiple steps for clinical reasoning. We guaranteed that one out of three proposals would be included as a paper in the written examination, possibly slightly modified. This article is an evaluation of the consequences of letting medical students set some of their own exam papers. The process was evaluated using 1) grades given, 2) students' assessment of whether this mode of setting papers influenced their exam preparations, and 3) students' free-text comments on the process. 57 out of 64 students (89%) took part in the evaluation. All knew that their fellow students had set one of the exam papers, but only 34 (60%) reported that this knowledge had changed the way they prepared for the exam. The mean grade was 9.9 (range 5-12, on a scale from 1 to 12, 6 being the lowest pass grade) for the paper set by students, and 9.5 (range 5-11) for all papers combined. Mean difference in score was 0.32 (95% confidence interval 0.08-0.64). Students' free-text comments showed that they specifically prepared for the three known paper topics. They drew comfort from knowing at least one of the papers set, and the student-set papers were found relevant for general practice. Letting medical students set one of the exam papers makes them feel more confident. Student-set papers were seen as relevant for clinical practice. The control function of the exam seemed to have been preserved.

  14. Improving Patient Safety: Avoiding Unread Imaging Exams in the National VA Enterprise Electronic Health Record.

    PubMed

    Bastawrous, Sarah; Carney, Benjamin

    2017-06-01

    In the current digital and filmless age of radiology, rates of unread radiology exams remain low, however, may still exist in unique environments. Veterans Affairs (VA) health care systems may experience higher rates of unread exams due to coexistence of Veterans Health Information Systems and Technology Architecture (VistA) imaging and commercial picture archiving and communication systems (PACS). The purpose of this patient safety initiative was to identify any unread exams and causes leading to unread exams. Following approval by departmental quality assurance committee, a comprehensive review was performed of all radiology exams within VistA imaging from July 1, 2009 to June 30, 2014 to identify unread radiology exams. Over the 5-year period, the total unread exam rate was calculated to be 0.17%, with the highest yearly unread exam rate of 0.25%. The leading majority of unread exam type was plain radiographs. Analysis revealed unfinished dictations, unassociated accession numbers, technologist errors, and inefficient radiologist work lists as top contributors to unread exams. Once unread radiology exams were discovered and the causes identified, valuable process changes were implemented within our department to ensure simultaneous tracking of all unread exams in VistA imaging as well as the commercial PACS.

  15. [Abdominal ultrasound abnormalities incidentally discovered in patients with asymptomatic HIV in Lome (Togo)].

    PubMed

    Sonhaye, L; Tchaou, M; Amadou, A; Gbande, P; Assih, K; Djibril, M; Adjenou, K; Redah, D; N'Dakéna, K

    2014-01-01

    Few studies have examined ultrasound imaging of abdominal manifestations of HIV-AIDS, although these rank second only to its pleuropulmonary manifestations. Thus, this study sought to determine the features of abdominal ultrasound in HIV infection. This prospective, descriptive and analytical study took place in the radiology department of the University Hospital Campus Lomé and covered the three-year period of 2009-2011. It included all patients older than 15 years with positive HIV serology. During the study period, 566 patients met the inclusion criteria. Ultrasound examination showed the liver appeared normal in 153 patients (27.0%), but homogeneously hyperechoic and thus suggestive of hepatic steatosis in 107 (18.9%). The bile duct was dilatated in 12 patients or 2.1%. An anomaly in the corticomedullary differentiation in normal-sized kidneys was noted in 28.1% (159 patients). Diffuse homogeneous hypertrophy of the pancreas was found in 3 patients (0.53%). Splenomegaly was noted in 387 patients (68.4%); the echopattern of the spleen was diffusely micronodular in 6 patients (1.1%). Deep adenopathies were found in 29 patients (5.1%) and ascites in 46 patients (8.1%). Abdominal ultrasound is a medical imaging technique available in developing countries, less expensive than others, which can be considered an alternative to computed tomography (CT) in the countries of sub-Saharan Africa for the exploration of the abdominal manifestations of HIV.

  16. Preparing Students to Take SOA/CAS Exam FM/2

    ERIC Educational Resources Information Center

    Marchand, Richard J.

    2014-01-01

    This paper provides suggestions for preparing students to take the actuarial examination on financial mathematics, SOA/CAS Exam FM/2. It is based on current practices employed at Slippery Rock University, a small public liberal arts university. Detailed descriptions of our Theory of Interest course and subsequent Exam FM/2 prep course are provided…

  17. MO-F-204-00: Preparing for the ABR Diagnostic and Nuclear Medical Physics Exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and

  18. MO-F-204-02: Preparing for Part 2 of the ABR Diagnostic Physics Exam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szczykutowicz, T.

    Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and

  19. MO-F-204-03: Preparing for Part 3 of the ABR Diagnostic Physics Exam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zambelli, J.

    Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and

  20. MO-F-204-01: Preparing for Part 1 of the ABR Diagnostic Physics Exam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenney, S.

    Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and