Science.gov

Sample records for abdominal radiography showed

  1. 5. INTERIOR VIEW, SHOWING A CONTROL ROOM INSIDE THE RADIOGRAPHY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. INTERIOR VIEW, SHOWING A CONTROL ROOM INSIDE THE RADIOGRAPHY ROOM; PASS-THROUGH FOR EXPOSED FILM ON RIGHT - Fort McCoy, Building No. T-1031, North side of South Tenth Avenue, Block 10, Sparta, Monroe County, WI

  2. Simulated and experimental technique optimization of dual-energy radiography: abdominal imaging applications

    NASA Astrophysics Data System (ADS)

    Sabol, John M.; Wheeldon, Samuel J.; Jabri, Kadri N.

    2006-03-01

    With growing clinical acceptance of dual-energy chest radiography, there is increased interest in the application of dual-energy techniques to other clinical areas. This paper describes the creation and experimental validation of a poly-energetic signal-propagation model for technique optimization of new dual-energy clinical applications. The model is verified using phantom experiments simulating typical abdominal radiographic applications such as Intravenous Urography (IVU) and the detection of pelvic and sacral bone lesions or kidney stones in the presence of bowel gas. The model is composed of a spectral signal propagation component and an image-processing component. The spectral propagation component accepts detector specifications, X-ray spectra, phantom and imaging geometry as inputs, and outputs the detected signal and estimated noise. The image-processing module performs dual-energy logarithmic subtraction and returns figures-of-merit such as contrast and contrast-to-noise ratio (CNR), which are evaluated in conjunction with Monte Carlo calculations of dose. Phantoms assembled from acrylic, aluminum, and iodinated contrast-agent filled tubes were imaged using a range of kVp's and dose levels. Simulated and experimental results were compared by dose, clinical suitability, and system limitations in order to yield technique recommendations that optimize one or more figures-of-merit. The model accurately describes phantom images obtained in a low scatter environment. For the visualization of iodinated vessels in the abdomen and the detection of pelvic bone lesions, both simulated and experimental results indicate that dual-energy techniques recommended by the model yield significant improvements in CNR without significant increases in patient dose as compared to conventional techniques. For example the CNR of iodinated vessels can be doubled using two-thirds of the dose of a standard exam. Alternatively, in addition to a standard dose image, the clinician can

  3. Radiography of the thoraco-abdominal cavity of the ostrich (Struthio camelus).

    PubMed

    Wagner, W M; Kirberger, R M

    2001-01-01

    A standard radiographic procedure was developed for the thoraco-abdominal cavity of female nonbreeding ostriches. Positioning, collimation, centering and a technique chart were defined to give reproducible and consistently good quality radiographs. Radiographs were obtained from one adult ostrich cadaver, two adult female ostriches as well as two growing ostriches at various stages. A 6-frame technique was established for lateral views taking the topographic tissue distribution into consideration and using easily palpable landmarks as centering points. Standing true right lateral radiographs are recommended for standard procedures. For dorsoventral exposures a 3-frame technique in the recumbent ostrich was found to be optimal. Birds should be fasted if possible. A technique chart for lateral exposures is provided.

  4. A Case Report of Postmortem Radiography of Acute, Fatal Abdominal Distension After Binge Eating.

    PubMed

    Usui, Akihito; Kawasumi, Yusuke; Ishizuka, Yuya; Hosokai, Yoshiyuki; Ikeda, Tomoya; Saito, Haruo; Funayama, Masato

    2016-12-01

    This case report describes a woman who developed fatal gastric dilatation after binge eating. She called an ambulance because of stomach pain. When she arrived at the hospital, she did not look seriously ill. However, she rapidly became unconscious and collapsed immediately after she was laid on the examination table in a supine position. Postmortem chest x-ray and computed tomography showed right shift of the mediastinum and raised left diaphragm caused by massive gastric distension. Computed tomography showed no visible inferior vena cava. We think that her sudden deterioration was caused by movement of her stomach contents. Radiographic images provided some clues to the cause of her rapid collapse and death.

  5. Industrial Radiography | Radiation Protection | US EPA

    EPA Pesticide Factsheets

    2016-12-09

    Manufacturers use a method called industrial radiography to check for cracks or flaws in materials. Radiation is used in industrial radiography to show problems not visible from the outside without damaging the material.

  6. Digital Radiography

    NASA Technical Reports Server (NTRS)

    1986-01-01

    System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

  7. Efficacy of extended thrombo-prophylaxis in major abdominal surgery: what does the evidence show? A meta-analysis.

    PubMed

    Bottaro, Federico Jorge; Elizondo, Maria Cristina; Doti, Carlos; Bruetman, Julio Enrique; Perez Moreno, Pablo Diego; Bullorsky, Eduardo Oscar; Ceresetto, Jose Manuel

    2008-06-01

    Venous thromboembolism (VTE) is a frequent complication following major abdominal surgery. The use of low-molecular-weight heparins (LMWH) to prevent thrombotic events in these patients is a common and well documented practice. However, there is some controversy surrounding the duration of the prophylaxis, as it has been suggested that the risk persists for several weeks after surgery. The objective of this meta-analysis is to systematically review the clinical studies that compared safety and efficacy of extended use of LMWH (for three to four weeks after surgery) versus conventional in-hospital prophylaxis. An electronic data base search was performed. Only randomized, controlled studies were eligible. Data on the incidence of deep vein thrombosis (DVT), VTE and bleeding were extracted. Only three studies fulfilled the inclusion criteria. The indication for surgery was neoplastic disease in 70.6% (780/1104) of patients. The administration of extended LMWH prophylaxis significantly reduced the incidence of VTE, 5.93% (23/388) versus 13.6% (55/405), RR 0.44 (CI 95% 0.28 - 0.7); DVT 5.93% (23/388) versus 12.9% (52/402), RR 0.46 (CI 95% 0.29 - 0.74); proximal DVT 1% (4/388) versus 4.72% (19/402), RR 0.24 (CI 95% 0.09 - 0.67). We found no significant difference in major or minor bleeding between the two groups: 3.85% (21/545) in the extended thrombo-prophylaxis (ETP) group versus 3.48% (19/559) in the conventional prophylaxis group; RR 1.12 (CI 95% 0.61 - 2.06). There was no heterogeneity between the studies. We conclude that ETP with LMWH should be considered as a safe and useful strategy to prevent VTE in high-risk major abdominal surgery.

  8. [Digital radiography].

    PubMed

    Haendle, J

    1983-03-01

    Digital radiography is a generally accepted term comprising all x-ray image systems producing a projected image which resembles the conventional x-ray film image, and which are linked to any type of digital image processing. Fundamental criteria of differentiation are based on the production and detection method of the x-ray image. Various systems are employed, viz. the single-detector, line-detector or fanbeam detector and the area-beam or area-detector image converters, which differ from one another mainly in the manner of conversion of the radiation produced by the x-ray tube. The article also deals with the pros and cons of the various principles, the multitude of systems employed, and the varying frequency of their use in x-ray diagnosis work.

  9. Intestinal obstruction due to migration of a thermometer from bladder to abdominal cavity: A case report

    PubMed Central

    Nie, Jing; Zhang, Bo; Duan, Yan-Chao; Hu, Yue-Hua; Gao, Xin-Ying; Gong, Jian; Cheng, Ming; Li, Yan-Qing

    2014-01-01

    Intraperitoneal foreign bodies such as retained surgical instruments can cause intestinal obstruction. However, intestinal obstruction due to transmural migration of foreign bodies has rarely been reported. Here, we report a case of intestinal obstruction due to a clinical thermometer which migrated from the bladder into the abdominal cavity. A 45-year-old man was admitted to our hospital with a one-year history of recurrent lower abdominal cramps. Two days before admission, the abdominal cramps aggravated. Intestinal obstruction was confirmed with upright abdominal radiography and computerized tomography scan which showed dilation of the small intestines and a thermometer in the abdominal cavity. Then laparotomy was performed. A scar was observed at the fundus of the bladder and a thermometer was adhering to the small bowels and mesentery which resulted in intestinal obstruction. Abdominal cramps were eliminated and defecation and flatus recovered soon after removal of the thermometer. PMID:24605042

  10. Intestinal obstruction due to migration of a thermometer from bladder to abdominal cavity: a case report.

    PubMed

    Nie, Jing; Zhang, Bo; Duan, Yan-Chao; Hu, Yue-Hua; Gao, Xin-Ying; Gong, Jian; Cheng, Ming; Li, Yan-Qing

    2014-03-07

    Intraperitoneal foreign bodies such as retained surgical instruments can cause intestinal obstruction. However, intestinal obstruction due to transmural migration of foreign bodies has rarely been reported. Here, we report a case of intestinal obstruction due to a clinical thermometer which migrated from the bladder into the abdominal cavity. A 45-year-old man was admitted to our hospital with a one-year history of recurrent lower abdominal cramps. Two days before admission, the abdominal cramps aggravated. Intestinal obstruction was confirmed with upright abdominal radiography and computerized tomography scan which showed dilation of the small intestines and a thermometer in the abdominal cavity. Then laparotomy was performed. A scar was observed at the fundus of the bladder and a thermometer was adhering to the small bowels and mesentery which resulted in intestinal obstruction. Abdominal cramps were eliminated and defecation and flatus recovered soon after removal of the thermometer.

  11. INDUSTRIAL RADIOGRAPHY INSTRUCTOR'S GUIDE.

    ERIC Educational Resources Information Center

    Bureau of Adult, Vocational, and Technical Education (DHEW/OE), Washington, DC. Div. of Vocational and Technical Education.

    THIS LABORATORY GUIDE WAS DEVELOPED FOR AN 80-HOUR COURSE IN INDUSTRIAL RADIOGRAPHY FOR HIGH SCHOOL GRADUATES TRAINING TO BECOME BEGINNING RADIOGRAPHERS. IT IS USED IN CONJUNCTION WITH TWO OTHER VOLUMES--(1) INDUSTRIAL RADIOGRAPHY INSTRUCTOR'S GUIDE, AND (2) INUDSTRIAL RADIOGRAPHY MANUAL. THE PROGRAM WAS DEVELOPED BY A COMMITTEE OF REPRESENTATIVES…

  12. Increasing mobile radiography productivity.

    PubMed

    Wong, Edward; Lung, Ngan Tsz; Ng, Kris; Jeor, Patrick

    2013-01-01

    Mobile radiography using computed radiography (CR) cassettes is a common equipment combination with a workflow bottleneck limited by location of CR readers. Advent of direct digital radiography (DDR) mobile x-ray machines removes this limitation by immediate image review and quality control. Through the use of key performance indicators (KPIs), the increase in efficiency can be quantified.

  13. Clinical feline dental radiography.

    PubMed

    Lemmons, Matthew

    2013-05-01

    Dental radiography is a necessary diagnostic modality in small animal practice. It is not possible to accurately assess and diagnose tooth resorption, periodontal disease, endodontic disease, neoplasia and injury without it. Dental radiography is also necessary for treatment and assessment of the patient postoperatively.

  14. Trichobezoars Detected and Treated Based on Plain Radiography.

    PubMed

    Barrows, Amy; Vachon, Tyler; Campin, Richard C; Ignacio, Romeo C

    2015-10-01

    Bezoars are conglomerations of indigestible material that become trapped in the gastrointestinal tract. We present a case of an 8-year-old female child diagnosed with a gastric bezoar solely on plain radiography and treated with abdominal surgical exploration and removal. In addition, traditional characteristic radiographic findings and treatment options for bezoars found in the current literature are reviewed.

  15. High energy neutron radiography

    SciTech Connect

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-06-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos.

  16. Phase-contrast radiography.

    PubMed

    Gao, D; Pogany, A; Stevenson, A W; Wilkins, S W

    1998-01-01

    For the past 100 years, the paradigm for radiography has been premised on absorption as the sole means of contrast formation and on ray optics as the basis for image interpretation. A new conceptual approach to radiography has been developed that includes phase (ie, refractive) contrast and requires wave optics for proper treatment. This new approach greatly increases the amount of information that can be obtained with radiographic techniques and is particularly well suited to the imaging of soft tissue and of very small features in biologic samples. A key feature of the present technique of phase-contrast radiography is the use of a microfocus x-ray source about an order of magnitude (< or = 20 microm) smaller than that used in conventional radiography. Phase-contrast radiography offers a number of improvements over conventional radiography in a clinical setting, especially in soft-tissue imaging. These improvements include increased contrast resulting in improved visualization of anatomic detail, reduced absorbed dose to the patient, inherent image magnification and high spatial resolution, use of harder x rays, and relative ease of implementation. More technologically advanced detectors are currently being developed and commercialized, which will help fully realize the considerable potential of phase-contrast imaging.

  17. Acute neonatal appendicitis: a diagnosis to consider in abdominal sepsis.

    PubMed

    Arias-Llorente, R P; Flórez-Díez, P; Oviedo-Gutiérrez, M; Suárez-Rodríguez, M; Costa-Romero, M; Solís-Sánchez, G; García-López, E

    2014-01-01

    Appendicitis in the neonatal period is extremely rare. Its low incidence together with non-specific clinical symptoms often mean the diagnosis is delayed, leading to increased rates of peritonitis and mortality. We report the case of a 33-week premature infant, small for gestational age (1180 g at birth), clinically stable and receiving exclusive enteral feeding, who presented clinical manifestations of necrotizing enterocolitis at 14 days of life. Acute phase reactants were elevated and abdominal radiography showed pneumoperitoneum. Laparotomy revealed acute perforated appendicitis without intestinal involvement and purulent fluid in the peritoneum, for which appendectomy was performed. Neonatal acute appendicitis should be considered in the differential diagnosis of abdominal sepsis since early diagnosis and treatment significantly reduce associated morbidity and mortality.

  18. 8. VIEW OF RADIOGRAPHY EQUIPMENT, TEST METHODS INCLUDED RADIOGRAPHY AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW OF RADIOGRAPHY EQUIPMENT, TEST METHODS INCLUDED RADIOGRAPHY AND BETA BACKSCATTERING. (7/13/56) - Rocky Flats Plant, Non-Nuclear Production Facility, South of Cottonwood Avenue, west of Seventh Avenue & east of Building 460, Golden, Jefferson County, CO

  19. Abdominal ultrasound

    MedlinePlus

    ... Kidney - blood and urine flow Abdominal ultrasound References Chen L. Abdominal ultrasound imaging. In: Sahani DV, Samir ... the Health on the Net Foundation (www.hon.ch). The information provided herein should not be used ...

  20. Abdominal tap

    MedlinePlus

    ... tap; Cirrhosis - abdominal tap; Malignant ascites - abdominal tap Images Digestive system Peritoneal sample References Garcia-Tiso G. ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  1. Recurrent tense pneumoperitoneum due to air influx via abdominal wall stoma of a PEG tube.

    PubMed

    Vijayakrishnan, Rajakrishnan; Adhikari, Deep; Anand, Curuchi P

    2010-07-28

    A 70 years old male on ventilatory and circulatory support for sepsis and non ST segment elevation myocardial infarction developed abdominal distension 14 d after placement of a percutaneous endoscopic gastrostomy tube for enteral feeding. Radiography revealed free air in the abdomen and gastrograffin (G) study showed no extravasation into the peritoneum. The G tube was successfully repositioned with mechanical release of air. Imaging showed complete elimination of free air but the patient had a recurrence of pneumoperitoneum. Mechanical release of air with sealing of the abdominal wound was performed. Later, the patient was restarted on tube feeding with no complications. This case demonstrates a late complication of pneumoperitoneum with air leakage from the abdominal wall stoma.

  2. Abdominal Pain

    MedlinePlus

    ... call your doctor. In Spanish— Dolor abdominal en niños menores de 12 años What is recurrent abdominal ... Functional abdominal pain (FAP) typically affects kids ages 4-12, and is quite common, affecting up to ...

  3. Real-time radiography

    SciTech Connect

    Bossi, R.H.; Oien, C.T.

    1981-02-26

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components.

  4. [Abdominal paracentesis].

    PubMed

    Glauser, Frédéric; Barras, Anne-Catherine; Pache, Isabelle; Monti, Matteo

    2008-10-29

    Abdominal paracentesis is frequently performed in the clinical setting. Every newly developed ascites need to be investigated by abdominal paracentesis. Any clinical or biological deterioration in patients with chronic ascites also requires a new paracentesis. Therapeutically abdominal paracentesis is performed for refractory or symptomatic ascites. As other invasive procedures, it is critical to master its indications, contra-indications and complications. The aim of this article is to review the basics of abdominal paracentesis in order to help physicians to carry out this technical skill.

  5. Apparatus for proton radiography

    DOEpatents

    Martin, Ronald L.

    1976-01-01

    An apparatus for effecting diagnostic proton radiography of patients in hospitals comprises a source of negative hydrogen ions, a synchrotron for accelerating the negative hydrogen ions to a predetermined energy, a plurality of stations for stripping extraction of a radiography beam of protons, means for sweeping the extracted beam to cover a target, and means for measuring the residual range, residual energy, or percentage transmission of protons that pass through the target. The combination of information identifying the position of the beam with information about particles traversing the subject and the back absorber is performed with the aid of a computer to provide a proton radiograph of the subject. In an alternate embodiment of the invention, a back absorber comprises a plurality of scintillators which are coupled to detectors.

  6. Forensic radiography: an overview.

    PubMed

    Reynolds, April

    2010-01-01

    Perhaps the first instance of forensic radiography occurred in the 1890s when Professor AW Wright of Yale University tested Wilhelm Roentgen's newly discovered x-ray photography on a deceased rabbit. Of interest were small, round objects inside the rabbit that appeared as dark spots on the positive film. The objects were extracted and identified as bullets, thereby helping to determine the cause of the rabbit's death. In the years since Roentgen's discovery, the use of radiography and other medical imaging specialties to aid in investigating civil and criminal matters has increased as investigators realize how radiologic technology can yield information that otherwise is unavailable. Radiologic technologists can play a key role in forensic investigations.

  7. Patient care in radiography

    SciTech Connect

    Ehrlich, R.A.; McCloskey, E.D.

    1989-01-01

    This book focuses on patient care procedures for radiographers. The authors focus on the role of the radiographer as a member of the health care team. The authors report on such topics as communication in patient care: safety, medico-legal considerations, transfer and positioning; physical needs; infection control; medication; CPR standards, acute situations; examination of the GI tract; contrast media; special imaging techniques and bedside radiography.

  8. Particle Beam Radiography

    NASA Astrophysics Data System (ADS)

    Peach, Ken; Ekdahl, Carl

    2014-02-01

    Particle beam radiography, which uses a variety of particle probes (neutrons, protons, electrons, gammas and potentially other particles) to study the structure of materials and objects noninvasively, is reviewed, largely from an accelerator perspective, although the use of cosmic rays (mainly muons but potentially also high-energy neutrinos) is briefly reviewed. Tomography is a form of radiography which uses multiple views to reconstruct a three-dimensional density map of an object. There is a very wide range of applications of radiography and tomography, from medicine to engineering and security, and advances in instrumentation, specifically the development of electronic detectors, allow rapid analysis of the resultant radiographs. Flash radiography is a diagnostic technique for large high-explosive-driven hydrodynamic experiments that is used at many laboratories. The bremsstrahlung radiation pulse from an intense relativistic electron beam incident onto a high-Z target is the source of these radiographs. The challenge is to provide radiation sources intense enough to penetrate hundreds of g/cm2 of material, in pulses short enough to stop the motion of high-speed hydrodynamic shocks, and with source spots small enough to resolve fine details. The challenge has been met with a wide variety of accelerator technologies, including pulsed-power-driven diodes, air-core pulsed betatrons and high-current linear induction accelerators. Accelerator technology has also evolved to accommodate the experimenters' continuing quest for multiple images in time and space. Linear induction accelerators have had a major role in these advances, especially in providing multiple-time radiographs of the largest hydrodynamic experiments.

  9. Abdominal pain

    MedlinePlus

    Stomach pain; Pain - abdomen; Belly ache; Abdominal cramps; Bellyache; Stomachache ... Almost everyone has pain in the abdomen at some point. Most of the time, it is not serious. How bad your pain is ...

  10. [Abdominal pain].

    PubMed

    Gschossmann, J M; Holtmann, G; Netzer, P; Essig, M; Balsiger, B M; Scheurer, U

    2005-10-01

    Abdominal pain can result from a variety of different intra- and extra-abdominal disorders. Given the wide variety of etiological triggers for this pain, the primary task during the first stage of the diagnostic work-up is to determine as soon as possible the underlying cause and the degree of emergency. The aim of this evaluation is to adapt the therapeutic measures which are necessary for a causal treatment to the individual situation. Contrary to somatic causes of abdominal pain, the availability of such a causal therapy for functional bowel disorders is still very limited. Given this dilemma, the therapeutic focus of abdominal pain associated with these functional syndromes has to be placed on symptom-oriented treatment.

  11. [Abdominal catastrophe--surgeon's view].

    PubMed

    Vyhnánek, F

    2010-07-01

    Abdominal catastrophe is a serious clinical condition, usually being a complication arising during treatment of intraabdominal nontraumatic disorders or abdominal injuries. Most commonly, inflamation- secondary peritonitis, is concerned. Abdominal catastrophe also includes secondary signs of sepsis, abdominal compartment syndrome and enterocutaneous fistules. Most septic abdominal disorders which show signs of abdominal catastrophy, require surgical intervention and reinterventions--planned or "on demand" laparotomies. During the postoperative period, the patient requires intensive care management, including steps taken to stabilize his/hers condition, management of sepsis and metabolic and nutritional support measures, as well as adequate indication for reoperations. New technologies aimed at prevention of complications in laparostomies and to improve conditions for final laparotomy closure are used in phase procedures for surgical management of intraabdominal infections. Despite the new technologies, abdominal catastrophe has higher morbidity and lethality risk rates.

  12. Abdominal Sepsis.

    PubMed

    De Waele, Jan J

    2016-08-01

    Abdominal infections are an important challenge for the intensive care physician. In an era of increasing antimicrobial resistance, selecting the appropriate regimen is important and, with new drugs coming to the market, correct use is important more than ever before and abdominal infections are an excellent target for antimicrobial stewardship programs. Biomarkers may be helpful, but their exact role in managing abdominal infections remains incompletely understood. Source control also remains an ongoing conundrum, and evidence is increasing that its importance supersedes the impact of antibiotic therapy. New strategies such as open abdomen management may offer added benefit in severely ill patients, but more data are needed to identify its exact role. The role of fungi and the need for antifungal coverage, on the other hand, have been investigated extensively in recent years, but at this point, it remains unclear who requires empirical as well as directed therapy.

  13. Digital radiography: an overview.

    PubMed

    Parks, Edwin T; Williamson, Gail F

    2002-11-15

    Since the discovery of X-rays in 1895, film has been the primary medium for capturing, displaying, and storing radiographic images. It is a technology that dental practitioners are the most familiar and comfortable with in terms of technique and interpretation. Digital radiography is the latest advancement in dental imaging and is slowly being adopted by the dental profession. Digital imaging incorporates computer technology in the capture, display, enhancement, and storage of direct radiographic images. Digital imaging offers some distinct advantages over film, but like any emerging technology, it presents new and different challenges for the practitioner to overcome. This article presents an overview of digital imaging including basic terminology and comparisons with film-based imaging. The principles of direct and indirect digital imaging modalities, intraoral and extraoral applications, image processing, and diagnostic efficacy will be discussed. In addition, the article will provide a list of questions dentists should consider prior to purchasing digital imaging systems for their practice.

  14. Abdominal Adhesions

    MedlinePlus

    ... Adhesions 1 Ward BC, Panitch A. Abdominal adhesions: current and novel therapies. Journal of Surgical Research. 2011;165(1):91–111. Seek Help for ... and how to participate, visit the NIH Clinical Research Trials and You website ... Foundation for Functional Gastrointestinal Disorders 700 West Virginia ...

  15. [Radiographic diagnosis of abdominal diseases in foals and ponys. II. Pathologic findings in 60 cases].

    PubMed

    Gerhards, H; Klein, H J; Offeney, F

    1990-08-01

    A diagnostic approach based on clinical and radiographic examinations for evaluation of young foals and small ponies with acute abdominal discomfort is presented. Standing right to left lateral abdominal radiographs were taken of 54 foals and 6 ponies using a previously described technique. Interpretation of the radiographs was in conjunction with all clinical and laboratory findings and patient management. Using this approach, the site and cause of acute abdominal discomfort could be diagnosed accurately in 55 of 60 (91%) patients as confirmed by clinical, surgical or necropsy findings. Typical radiographs and photographs taken at surgery or at necropsy are presented. Typical radiographic findings, their interpretation and possible underlying gastrointestinal diseases are listed. The incorporation of standing lateral abdominal radiography in the clinical evaluation of foals and ponies with acute abdominal diseases gives findings of high diagnostic significance and should contribute to clinical decision-making. Abdominal radiography can replace data from rectal palpation in foals and ponies.

  16. Monte Carlo calculation for microplanar beam radiography.

    PubMed

    Company, F Z; Allen, B J; Mino, C

    2000-09-01

    In radiography the scattered radiation from the off-target region decreases the contrast of the target image. We propose that a bundle of collimated, closely spaced, microplanar beams can reduce the scattered radiation and eliminate the effect of secondary electron dose, thus increasing the image dose contrast in the detector. The lateral and depth dose distributions of 20-200 keV microplanar beams are investigated using the EGS4 Monte Carlo code to calculate the depth doses and dose profiles in a 6 cm x 6 cm x 6 cm tissue phantom. The maximum dose on the primary beam axis (peak) and the minimum inter-beam scattered dose (valley) are compared at different photon energies and the optimum energy range for microbeam radiography is found. Results show that a bundle of closely spaced microplanar beams can give superior contrast imaging to a single macrobeam of the same overall area.

  17. Contrast enhancement in microplanar beam radiography.

    PubMed

    Company, F Z; Allen, B J; Mino, C

    1999-12-01

    In x-ray radiography, the target produces a useful shadow from absorption of the primary beam, while the scattered radiation into the off-target region decreases the contrast of the target image. A bundle of closely spaced microplanar beams can reduce the scattered radiation and give superior image contrast compared with a single macrobeam of the same dimensions. To further reduce the scattered radiation and increase the image contrast, we place an air gap between the tissue phantom and the detector. The primary and scattered photon flux of a single microplanar beam is measured as a function of thickness inside the phantom and in the air gap. Results show that a bundle of closely spaced, microplanar beams increase the image contrast by 22% and a 2 cm air gap decreases the scattered photon flux by about half, improving the contrast by an additional 16%. Thus an overall improvement of 41% in contrast can be achieved with microplanar beam radiography.

  18. Proton Radiography Peers into Metal Solidification

    DOE PAGES

    Clarke, Amy J.; Imhoff, Seth D.; Gibbs, Paul J.; ...

    2013-06-19

    Historically, metals are cut up and polished to see the structure and to infer how processing influences the evolution. We can now peer into a metal during processing without destroying it using proton radiography. Understanding the link between processing and structure is important because structure profoundly affects the properties of engineering materials. Synchrotron x-ray radiography has enabled real-time glimpses into metal solidification. However, x-ray energies favor the examination of small volumes and low density metals. In this study, we use high energy proton radiography for the first time to image a large metal volume (>10,000 mm3) during melting and solidification.more » We also show complementary x-ray results from a small volume (<1mm3), bridging four orders of magnitude. In conclusion, real-time imaging will enable efficient process development and the control of the structure evolution to make materials with intended properties; it will also permit the development of experimentally informed, predictive structure and process models.« less

  19. Newer imaging methods in chest radiography.

    PubMed

    Wandtke, J C

    1990-01-01

    In recent years the application of computers to chest radiography has resulted in a wide variety of innovative research. Major research efforts have resulted in the development of new types of x-ray detectors, such as storage phosphor technology, for use with computers. Storage phosphor imaging is one of the most promising new techniques, and almost 100 systems have been installed worldwide. Radiologists are quickly evaluating the image quality provided by this new detector system, which has the potential to improve image quality. It has wide latitude and is coupled with a computer to perform image processing. Another promising technology, originally studied in the form of scan equalization radiography, is now commercially available in the form of advanced multiple-beam equalization radiography. This film technique uses computers to modulate the x-ray exposure to take maximum advantage of the imaging capabilities of radiographic film. Digital solid-state detectors have been studied in conjunction with computerized image enhancement systems. These currently show improvement in nodule detection and quantification of the calcium content of a lesion. Application of large image intensifiers to a digital image system is being studied, but there are currently limitations on spatial resolution.

  20. Proton Radiography Peers into Metal Solidification

    SciTech Connect

    Clarke, Amy J.; Imhoff, Seth D.; Gibbs, Paul J.; Cooley, Jason C.; Morris, Christopher; Merrill, Frank E.; Hollander, Brian J.; Mariam, Fesseha G.; Ott, Thomas J.; Barker, Martha R.; Tucker, Tim J.; Lee, Wah-Keat; Fezzaa, Kamel; Deriy, Alex; Patterson, Brian M.; Clarke, Kester D.; Montalvo, Joel D.; Field, Robert D.; Thoma, Dan J.; Smith, James L.; Teter, David F.

    2013-06-19

    Historically, metals are cut up and polished to see the structure and to infer how processing influences the evolution. We can now peer into a metal during processing without destroying it using proton radiography. Understanding the link between processing and structure is important because structure profoundly affects the properties of engineering materials. Synchrotron x-ray radiography has enabled real-time glimpses into metal solidification. However, x-ray energies favor the examination of small volumes and low density metals. In this study, we use high energy proton radiography for the first time to image a large metal volume (>10,000 mm3) during melting and solidification. We also show complementary x-ray results from a small volume (<1mm3), bridging four orders of magnitude. In conclusion, real-time imaging will enable efficient process development and the control of the structure evolution to make materials with intended properties; it will also permit the development of experimentally informed, predictive structure and process models.

  1. Impact of digital radiography on clinical workflow.

    PubMed

    May, G A; Deer, D D; Dackiewicz, D

    2000-05-01

    It is commonly accepted that digital radiography (DR) improves workflow and patient throughput compared with traditional film radiography or computed radiography (CR). DR eliminates the film development step and the time to acquire the image from a CR reader. In addition, the wide dynamic range of DR is such that the technologist can perform the quality-control (QC) step directly at the modality in a few seconds, rather than having to transport the newly acquired image to a centralized QC station for review. Furthermore, additional workflow efficiencies can be achieved with DR by employing tight radiology information system (RIS) integration. In the DR imaging environment, this provides for patient demographic information to be automatically downloaded from the RIS to populate the DR Digital Imaging and Communications in Medicine (DICOM) image header. To learn more about this workflow efficiency improvement, we performed a comparative study of workflow steps under three different conditions: traditional film/screen x-ray, DR without RIS integration (ie, manual entry of patient demographics), and DR with RIS integration. This study was performed at the Cleveland Clinic Foundation (Cleveland, OH) using a newly acquired amorphous silicon flat-panel DR system from Canon Medical Systems (Irvine, CA). Our data show that DR without RIS results in substantial workflow savings over traditional film/screen practice. There is an additional 30% reduction in total examination time using DR with RIS integration.

  2. [Abdominal actinomycosis with IUD].

    PubMed

    Kamprath, S; Merker, A; Kühne-Heid, R; Schneider, A

    1997-01-01

    We report a case of abdominal actinomycosis in a 54 year old woman using an intrauterine device for a period of 8 years. The most important finding was a tuboovarialabscess at the left pelvic side with involvement of the serosa of the jejunum, ileum, sigma, and omentum majus. Intraoperative exploration showed a solid retroperitoneal infiltration between the pelvic side wall and sigma. Another infiltration was found on the left side of the abdominal wall. The diagnosis was confirmed by histopathological examination and the patient was treated by a combination of Aminopenicillin and Metronidazol. After a period of three months we observed a complete regression of the clinical and the MRI findings.

  3. Lower Gastrointestinal (GI) Tract X-Ray (Radiography)

    MedlinePlus

    ... Site Index A-Z X-ray (Radiography) - Lower GI Tract Lower gastrointestinal tract radiography or lower GI ... of Lower GI Tract Radiography? What is Lower GI Tract X-ray Radiography (Barium Enema)? Lower gastrointestinal ( ...

  4. Methodology for digital radiography simulation using the Monte Carlo code MCNPX for industrial applications.

    PubMed

    Souza, E M; Correa, S C A; Silva, A X; Lopes, R T; Oliveira, D F

    2008-05-01

    This work presents a methodology for digital radiography simulation for industrial applications using the MCNPX radiography tally. In order to perform the simulation, the energy-dependent response of a BaFBr imaging plate detector was modeled and introduced in the MCNPX radiography tally input. In addition, a post-processing program was used to convert the MCNPX radiography tally output into 16-bit digital images. Simulated and experimental images of a steel pipe containing corrosion alveoli and stress corrosion cracking were compared, and the results showed good agreement between both images.

  5. Accelerator system for neutron radiography

    SciTech Connect

    Rusnak, B; Hall, J

    2000-09-21

    The field of x-ray radiography is well established for doing non-destructive evaluation of a vast array of components, assemblies, and objects. While x-rays excel in many radiography applications, their effectiveness diminishes rapidly if the objects of interest are surrounded by thick, high-density materials that strongly attenuate photons. Due to the differences in interaction mechanisms, neutron radiography is highly effective in imaging details inside such objects. To obtain a high intensity neutron source suitable for neutron imaging a 9-MeV linear accelerator is being evaluated for putting a deuteron beam into a high-pressure deuterium gas cell. As a windowless aperture is needed to transport the beam into the gas cell, a low-emittance is needed to minimize losses along the high-energy beam transport (HEBT) and the end station. A description of the HEBT, the transport optics into the gas cell, and the requirements for the linac will be presented.

  6. Digital Radiography: A Technology Overview

    NASA Astrophysics Data System (ADS)

    Arnold, Ben A.

    1982-12-01

    Digital radiography, a term hardly recognized two years ago, has grown to become the talk of the radiology community and the excitement of many commercial companies. M2st of this attention has been directed toward digital subtraction intravenous angiography), although during this same time period, a variety of digital radiography apparatus and image processing techniques have been under development. In November of 1980 at the RSNA Conference in Chicago, three commercial digital angiography systems were announced by Philips, Technicare and ADAC Corporations. During this same time period, the University of Arizona was discussing the concept of a photo electronic radiology department2, the University of Pittsburg and Stanford University were investigating line scan radiography3,4 and approximately five laboratories were carrying out clinical IV angiography with digital video systems.5-9 These developments followed basic research programs in digital electronic and computerized imaging at various locations around the world. 10-18 In the spring of 1981 we attempted to review the state of digital radiography, focusing on the various detector systems and image acquisition approaches.19 Since that time, rapid advancements in digital radiography have occurred. A major conference was held on digital radiography at Stanford UniversityzO, a new area detector system for digital radiography was announced by Fuji Film Corporation, clinical testing began on the Picker line scan digital chest unit21, and improvements were made in selenium detectors for digital radiography. Several additional companies announced digital video angiography systems, bringing the total now to approximately 15 companies worldwide. Digital video subtraction angiography is now well established as an important clinical diagnostic procedure and a variety of improvements and extensions of digital angiography systems are now ongoing. Digital acquisition and storage systems are increasing in both speed and

  7. Diagnostic value of FASH ultrasound and chest X-ray in HIV-co-infected patients with abdominal tuberculosis.

    PubMed

    Heller, T; Goblirsch, S; Bahlas, S; Ahmed, M; Giordani, M-T; Wallrauch, C; Brunetti, E

    2013-03-01

    In human immunodeficiency virus (HIV) co-infected tuberculosis (TB) patients with negative acid-fast bacilli smears, chest radiography (CXR) is usually the first imaging step in the diagnostic work-up. Ultrasound, also in the form of focused assessment with sonography for TB-HIV (FASH), is an additional imaging modality used to diagnose extra-pulmonary TB (EPTB). Findings from 82 patients with abdominal TB diagnosed by ultrasound were analysed and compared with CXR results. Enlarged abdominal lymph nodes were seen in 75.6% of the patients, spleen abscesses in 41.2% and liver lesions in 30.6%. CXR showed a miliary pattern in 21.9% of the patients; 26.8% of the CXR had no radiological changes suggestive of pulmonary TB. This patient group would benefit from ultrasound in diagnostic algorithms for HIV-associated EPTB.

  8. Abdominal tuberculosis.

    PubMed Central

    Kapoor, V. K.

    1998-01-01

    Tuberculosis has staged a global comeback and forms a dangerous combination with AIDS. The abdomen is one of the common sites of extrapulmonary involvement. Patients with abdominal tuberculosis have a wide range and spectrum of symptoms and signs; the disease is therefore a great mimic. Diagnosis, mainly radiological and supported by endoscopy, is difficult to make and laparotomy is required in a large number of patient. Management involves judicious combination of antitubercular therapy and surgery which may be required to treat complications such as intestinal obstruction and perforation. The disease, though potentially curable, carries a significant morbidity and mortality. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 PMID:9926119

  9. Evaluation of a Noise Reduction Procedure for Chest Radiography

    PubMed Central

    Fukui, Ryohei; Ishii, Rie; Kodani, Kazuhiko; Kanasaki, Yoshiko; Suyama, Hisashi; Watanabe, Masanari; Nakamoto, Masaki; Fukuoka, Yasushi

    2013-01-01

    Background The aim of this study was to evaluate the usefulness of noise reduction procedure (NRP), a function in the new image processing for chest radiography. Methods A CXDI-50G Portable Digital Radiography System (Canon) was used for X-ray detection. Image noise was analyzed with a noise power spectrum (NPS) and a burger phantom was used for evaluation of density resolution. The usefulness of NRP was evaluated by chest phantom images and clinical chest radiography. We employed the Bureau of Radiological Health Method for scoring chest images while carrying out our observations. Results NPS through the use of NRP was improved compared with conventional image processing (CIP). The results in image quality showed high-density resolution through the use of NRP, so that chest radiography examination can be performed with a low dose of radiation. Scores were significantly higher than for CIP. Conclusion In this study, use of NRP led to a high evaluation in these so we are able to confirm the usefulness of NRP for clinical chest radiography. PMID:24574577

  10. [Significance of plain radiography in shoulder pain diagnosis].

    PubMed

    Botser, Itamar Busheri; Shapira, Shachar; Oran, Ariel; Avivi, Eran; Pritsch, Moshe

    2011-09-01

    Shoulder pain is a common complaint--almost 20% of the population will suffer shoulder pain during their life time. Despite the availability of newer imaging techniques for evaluation of the shoulder, the first imaging study should be radiography. Recently, ultrasonography of the shoulder has become one of the first studies performed. Sometimes, ultrasonography is conducted before radiography; moreover, many patients are being referred to a shoulder specialist without performing an X-ray. There is a plethora of pathologies that can cause shoulder pain--rotator cuff tears, impingement syndrome, calcified tendinitis, osteoarthritis, rheumatoid arthritis, neoplasms and more. This review aims to show the significance of plain radiography in the diagnosis of shoulder pathologies, in order to encourage the use of this modality. In this paper we shall review the different causes of shoulder pain and their radiographic characteristics.

  11. Pilot study of bovine interdigital cassetteless computed radiography.

    PubMed

    El-Shafaey, El-Sayed Ahmed Awad; Aoki, Takahiro; Ishii, Mitsuo; Yamada, Kazutaka

    2013-11-01

    Twenty-one limbs of bovine cadavers (42 digits) were exposed to interdigital cassetteless imaging plate using computed radiography. The radiographic findings included exostosis, a rough planta surface, osteolysis of the apex of the distal phalanx and widening of the laminar zone between the distal phalanx and the hoof wall. All these findings were confirmed by computed tomography. The hindlimbs (19 digits) showed more changes than the forelimbs (10 digits), particularly in the lateral distal phalanx. The cassetteless computed radiography technique is expected to be an easily applicable method for the distal phalanx rather than a conventional cassette-plate and/or the film-screen cassetteless methods.

  12. Free-focus radiography using conventional films: Radiation exposures in a simulated clinical study

    SciTech Connect

    Jensen, T.W.; Randall, G.J.; Goldberg, A.J.

    1980-07-01

    This study compared air exposures during conventional dental and maxillofacial radiography and similar views using free-focus radiography with conventional image receptors. The results show that periapical type surveys on nonscreen film placed extraorally or in the buccal fold may be carried out with an exposure to the surface tissues, which is similar to or less than conventional dental radiography. Extraoral survey type radiographs of the jaws may be carried out with significantly less surface exposure than lateral oblique views of the jaws. The least exposure was required, when the film was placed in the buccla fold instead of against the face during free-focus radiography. The exposures with film screen combinations were reduced by an order of magnitude when compared to the nonscreen techniques. Proper filtration of the beam of the miniaturized x-ray machines radiography in dentistry may thus be desirable and applications in other parts of the body encouraged.

  13. System for uncollimated digital radiography

    DOEpatents

    Wang, Han; Hall, James M.; McCarrick, James F.; Tang, Vincent

    2015-08-11

    The inversion algorithm based on the maximum entropy method (MEM) removes unwanted effects in high energy imaging resulting from an uncollimated source interacting with a finitely thick scintillator. The algorithm takes as input the image from the thick scintillator (TS) and the radiography setup geometry. The algorithm then outputs a restored image which appears as if taken with an infinitesimally thin scintillator (ITS). Inversion is accomplished by numerically generating a probabilistic model relating the ITS image to the TS image and then inverting this model on the TS image through MEM. This reconstruction technique can reduce the exposure time or the required source intensity without undesirable object blurring on the image by allowing the use of both thicker scintillators with higher efficiencies and closer source-to-detector distances to maximize incident radiation flux. The technique is applicable in radiographic applications including fast neutron, high-energy gamma and x-ray radiography using thick scintillators.

  14. Walking on thin ice! Identifying methamphetamine “drug mules” on digital plain radiography

    PubMed Central

    Abdul Rashid, S N; Mohamad Saini, S B; Abdul Hamid, S; Muhammad, S J; Mahmud, R; Thali, M J

    2014-01-01

    Objective: The purpose of this study was to retrospectively evaluate the sensitivity, specificity and accuracy of identifying methamphetamine (MA) internal payloads in “drug mules” by plain abdominal digital radiography (DR). Methods: The study consisted of 35 individuals suspected of internal MA drug containers. A total of 59 supine digital radiographs were collected. An overall calculation regarding the diagnostic accuracy for all “drug mules” and a specific evaluation concerning the radiological appearance of drug packs as well as the rate of clearance and complications in correlation with the reader's experience were performed. The gold standard was the presence of secured drug packs in the faeces. Results: There were 16 true-positive “drug mules” identified. DR of all drug carriers for Group 1 (forensic imaging experienced readers, n = 2) exhibited a sensitivity of 100%, a mean specificity of 76.3%, positive predictive value (PPV) of 78.5%, negative predictive value (NPV) of 100% and a mean accuracy 87.2%. Group 2 (inexperienced readers, n = 3) showed a lower sensitivity (93.7%), a mean specificity of 86%, a PPV of 86.5%, an NPV of 94.1% and a mean accuracy of 89.5%. The interrater agreement within Group 1 was 0.72 and within Group 2 averaged to 0.79, indicating a fair to very good agreement. Conclusion: DR is a valuable screening tool in cases of MA body packers with huge internal payloads being associated with a high diagnostic insecurity. Diagnostic insecurity on plain films may be overcome by low-dose CT as a cross-sectional imaging modality and addressed by improved radiological education in reporting drug carriers on imaging. Advances in knowledge: Diagnostic signs (double-condom and halo signs) on digital plain radiography are specific in MA “drug mules”, although DR is associated with high diagnostic insecurity and underreports the total internal payload. PMID:24472728

  15. Functional abdominal pain

    PubMed Central

    Matthews, P; Aziz, Q

    2005-01-01

    Functional abdominal pain or functional abdominal pain syndrome (FAPS) is an uncommon functional gut disorder characterised by chronic or recurrent abdominal pain attributed to the gut but poorly related to gut function. It is associated with abnormal illness behaviour and patients show psychological morbidity that is often minimised or denied in an attempt to discover an organic cause for symptoms. Thus the conventional biomedical approach to the management of such patients is unhelpful and a person's symptom experience is more usefully investigated using a biopsychosocial evaluation, which necessarily entails a multidisciplinary system of healthcare provision. Currently the pathophysiology of the disorder is poorly understood but is most likely to involve a dysfunction of central pain mechanisms either in terms of attentional bias, for example, hypervigilance or a failure of central pain modulation/inhibition. Although modern neurophysiological investigation of patients is promising and may provide important insights into the pathophysiology of FAPS, current clinical management relies on an effective physician-patient relationship in which limits on clinical investigation are set and achievable treatment goals tailored to the patient's needs are pursued. PMID:15998821

  16. Imaging properties of digital magnification radiography.

    PubMed

    Boyce, Sarah J; Samei, Ehsan

    2006-04-01

    Flat panel detectors exhibit improved signal-to-noise ratio (SNR) and display capabilities compared to film. This improvement necessitates a new evaluation of optimal geometry for conventional projection imaging applications such as digital projection mammography as well as for advanced x-ray imaging applications including cone-beam computed tomography (CT), tomosynthesis, and mammotomography. Such an evaluation was undertaken in this study to examine the effects of x-ray source distribution, inherent detector resolution, magnification, scatter rejection, and noise characteristics including noise aliasing. A model for x-ray image acquisition was used to develop generic results applicable to flat panel detectors with similar x-ray absorption characteristics. The model assumed a Gaussian distribution for the focal spot and a rectangular distribution for a pixel. A generic model for the modulated transfer function (MTF) of indirect flat panel detectors was derived by a nonlinear fit of empirical receptor data to the Burgess model for phosphor MTFs. Noise characteristics were investigated using a generic noise power spectrum (NPS) model for indirect phosphor-based detectors. The detective quantum efficiency (DQE) was then calculated from the MTF and NPS models. The results were examined as a function of focal spot size (0.1, 0.3, and 0.6 mm) and pixel size (50, 100, 150, and 200 microm) for magnification ranges 1 to 3. Mammography, general radiography (also applicable to mammotomography), and chest radiography applications were explored using x-ray energies of 28, 74, and 120 kVp, respectively. Nodule detection was examined using the effective point source scatter model, effective DQE, and the Hotelling SNR2 efficiency. Results indicate that magnification can potentially improve the signal and noise performance of digital images. Results also show that a cross over point occurs in the spatial frequency above and below which the effects of magnification differ

  17. Abdominal tumors in children

    PubMed Central

    Oh, Chaeyoun; Youn, Joong Kee; Han, Ji-Won; Kim, Hyun-Young; Jung, Sung-Eun

    2016-01-01

    Abstract The use of minimally invasive surgery (MIS) in pediatric patients has been steadily increasing in recent years. However, its use for diagnosing and treating abdominal tumors in children is still limited compared with adults, especially when malignancy is a matter of debate. Here, we describe the experience at our center with pediatric abdominal tumors to show the safety and feasibility of MIS. Based on a retrospective review of patient records, we selected for study those pediatric patients who had undergone diagnostic exploration or curative resection for abdominal tumors at a single center from January 2010 through August 2015. Diagnostic exploration for abdominal tumors was performed in 32 cases and curative resection in 173 cases (205 operations). MIS was performed in 11 cases of diagnostic exploration (34.4%) and 38 cases of curative resection (21.9%). The mean age of the children who underwent MIS was 6.09 ± 5.2 years. With regard to diagnostic exploration, patient characteristics and surgical outcomes were found to be similar for MIS and open surgery. With regard to curative resection, however, the mean age was significantly lower among the patients who underwent open surgery (4.21 ± 4.20 vs 6.02 ± 4.99 for MIS, P = 0.047), and the proportion of malignancies was significantly higher (80% vs 39.4% for MIS, P < 0.001). MIS compared favorably with open surgery with respect to the rate of recurrence (6.7% vs 35.1%, P = 0.035), the rate of intraoperative transfusions (34.2% vs 58.5%, P = 0.01), the median amount of blood transfused (14 vs 22 mL/kg, P = 0.001), and the mean number of hospital days (4.66 ± 2.36 vs 7.21 ± 5.09, P < 0.001). Complication rates did not differ significantly between the MIS and open surgery groups. The operation was converted to open surgery in 3 cases (27.2%) of diagnostic MIS and in 5 cases (13.1%) of curative MIS. MIS was found to be both feasible and effective for the

  18. Lesion detectability in digital radiography

    NASA Astrophysics Data System (ADS)

    Gagne, Robert M.; Boswell, Jonathan S.; Myers, Kyle J.; Peter, Guillaume

    2001-06-01

    The usefulness of Fourier-based measures of imaging performance has come into question for the evaluation of digital imaging systems. Figures of merit such as detective quantum efficiency are relevant for linear, shift-invariant systems with stationary noise. However, no digital imaging system is shift invariant, and realistic images do not satisfy the stationarity condition. Our methods for task- based evaluation of imaging systems, based on lesion detectability, do not require such assumptions. We have computed the performance of Hotelling and nonprewhitening matched-filter observers for the task of lesion detection in digital radiography.

  19. Patient risk from interproximal radiography

    SciTech Connect

    Gibbs, S.J.; Pujol, A. Jr.; Chen, T.S.; Malcolm, A.W.; James, A.E. Jr.

    1984-09-01

    Computer simulation methods for determining patient dose from dental radiography have demonstrated that patient risk from a two-film interproximal examination ranges from 1.1 X 10(-8) to 3.4 X 10(-7) using 90-kVp beams, depending on film speed, projection technique, and age and sex of the patient. Further, changing from a short-cone round-beam to a long-cone technique with rectangular collimation reduces risk by a factor of 2.9, independent of other factors.

  20. Hardware Accelerated Simulated Radiography

    SciTech Connect

    Laney, D; Callahan, S; Max, N; Silva, C; Langer, S; Frank, R

    2005-04-12

    We present the application of hardware accelerated volume rendering algorithms to the simulation of radiographs as an aid to scientists designing experiments, validating simulation codes, and understanding experimental data. The techniques presented take advantage of 32 bit floating point texture capabilities to obtain validated solutions to the radiative transport equation for X-rays. An unsorted hexahedron projection algorithm is presented for curvilinear hexahedra that produces simulated radiographs in the absorption-only regime. A sorted tetrahedral projection algorithm is presented that simulates radiographs of emissive materials. We apply the tetrahedral projection algorithm to the simulation of experimental diagnostics for inertial confinement fusion experiments on a laser at the University of Rochester. We show that the hardware accelerated solution is faster than the current technique used by scientists.

  1. Abdominal Aortic Aneurysm (AAA)

    MedlinePlus

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  2. Abdominal aortic aneurysm

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/000162.htm Abdominal aortic aneurysm To use the sharing features on this page, ... blood to the abdomen, pelvis, and legs. An abdominal aortic aneurysm occurs when an area of the aorta becomes ...

  3. ARG portable neutron radiography. Final report

    SciTech Connect

    Barton, J.P.

    1995-04-01

    In this report all available neutron radiographic data, including results of tests run at LANL, McClellan AFB, and University of Virginia, will be combined to outline specific transportable neutron radiography systems that could achieve the desired results as a complement to x-radiography capabilities for the Accident Response Group (ARG).

  4. Radiological protection in equine radiography and radiotherapy.

    PubMed

    Yoxall, A T

    1977-10-01

    The principles of radiological protection are summarised and consideration is then given to problems, which may confront the equine practitioner, in the fulfillment of these principles during diagnostic radiography of the limbs, head, and spine of the horse. The place of anaesthesia in such procedures is discussed and the special problems associated with therapeutic radiography of the horse are considered.

  5. INDUSTRIAL RADIOGRAPHY STUDENT GUIDE AND LABORATORY EXERCISES.

    ERIC Educational Resources Information Center

    Bureau of Adult, Vocational, and Technical Education (DHEW/OE), Washington, DC. Div. of Vocational and Technical Education.

    THIS INSTRUCTOR'S GUIDE TO AN 80-HOUR COURSE IN INDUSTRIAL RADIOGRAPHY IS COORDINATED WITH LESSONS IN THE STUDENT GUIDE AND LABORATORY EXERCISES AND IS BASED ON MATERIAL IN THE COURSE MANUAL, INDUSTRIAL RADIOGRAPHY. THE COURSE IS INTENDED TO TRAIN HIGH SCHOOL GRADUATES AS BEGINNING RADIOGRAPHERS WHO ARE EXPECTED TO BE ABLE TO EXTEND THEIR…

  6. PROTON RADIOGRAPHY FOR AN ADVANCED HYDROTEST FACILITY

    SciTech Connect

    C. MORRIS

    2000-11-01

    Analysis of data from BNL experiment 933 is presented. Results demonstrate that proton radiography can meet many of the requirements for an Advanced Hydrotest Facility (AHF). Results for background, position resolution, metrology, quantitative radiography, material identification, and edge resolution are presented.

  7. Process waste assessment for the Radiography Laboratory

    SciTech Connect

    Phillips, N.M.

    1994-07-01

    This Process Waste Assessment was conducted to evaluate the Radiography Laboratory, located in Building 923. It documents the processes, identifies the hazardous chemical waste streams generated by these processes, recommends possible ways to minimize waste, and serves as a reference for future assessments of this facility. The Radiography Laboratory provides film radiography or radioscopy (electronic imaging) of weapon and nonweapon components. The Radiography Laboratory has six x-ray machines and one gamma ray source. It also has several other sealed beta- and gamma-ray isotope sources of low microcurie ({mu}Ci) activity. The photochemical processes generate most of the Radiography Laboratory`s routinely generated hazardous waste, and most of that is generated by the DuPont film processor. Because the DuPont film processor generates the most photochemical waste, it was selected for an estimated material balance.

  8. Polarized neutron radiography with a periscope

    NASA Astrophysics Data System (ADS)

    Schulz, Michael; Neubauer, Andreas; Mühlbauer, Martin; Calzada, Elbio; Schillinger, Burkhard; Pfleiderer, Christian; Böni, Peter

    2010-01-01

    The interaction of the magnetic moment of the neutron with magnetic fields provides a powerful probe for spatially resolved magnetisation measurements in magnetic materials. We have tested a periscope as a new type of polarizer providing neutron beams with a high polarization and a low divergence. The observed inhomogeneity of the beam caused by the waviness of the glass substrates was quantified by means of Monte-Carlo simulations using the software package McStas. The results show that beams of high homogeneity can be produced if the waviness is reduced to below 1.0·10-5 rad. Finally, it is shown that radiography with polarized neutrons is a powerful method for measuring the spatially resolved magnetisation in optically float-zoned samples of the weak itinerant ferromagnet Ni3Al, thereby aiding the identification of the appropriate growth parameters.

  9. Direct magnification radiography of the newborn infant

    SciTech Connect

    Brasch, R.C.; Gould, R.G.

    1982-03-01

    Recent advances in technology have made direct radiographic magnification of the newborn infant clinically feasible. A microfocus radiographic tube and a rare-earth, high-speed recording system were combined to obtain more than 2,000 radiographs at magnifications of 2-2.5. Special positioning devices permitted imaging of even those infants confined to incubators and connected to life-supporting systems. When quantitatively compared with three conventional contact radiographic systems with respect to resolution, contrast, and noise, magnification radiography showed overall superiority of image characteristics. Definition of subtle abnormalities and anatomically small structures permitted diagnoses which could not be made from conventional images. Furthermore, infant radiation exposure was markedly less (15 mR (3.9 mC/kg) maximum skin exposure) as compared with conventional contact radiographic systems (24 mR (6.1 mC/kg) to 45 mR (11.6 mC/kg)).

  10. Direct magnification radiography of the newborn infant

    SciTech Connect

    Brasch, R.C.; Gould, R.G.

    1982-03-01

    Recent advances in technology have made direct radiographic magnification of the newborn infant clinically feasible. A microfocus radiographic tube and a rare-earth, high-speed recording system were combined to obtain more than 2,000 radiographs at magnifications of 2 to 2.5. Special positioning devices permitted imaging of even those infants confined to incubators and connected to life-supporting systems. When quantitatively compared with three conventional contact radiographic systems with respect to resolution, contrast, and noise, magnification radiography showed overall superiority of image characteristics. Definition of subtle abnormalities and anatomically small structures permitted diagnoses which could not be made from conventional images. Furthermore, infant radiation exposure was markedly less (15 mR (3.9 mC/kg) maximum skin exposure) as compared with conventional contact radiographic systems (24 mR(6.1 mC/kg) to 45 mR (11.6 mC/kg)).

  11. Quality assurance in film radiography

    SciTech Connect

    Van Bellegem, L.; Vaessen, B.

    1993-12-31

    The ISO 9000 standards were originally developed during the 1980`s to provide uniform, worldwide quality assurance requirements. The EC (European Communities) adopted these standards as part of their modular approach to ``conformity assessment`` procedures, for several product categories. This includes the development of standards (specifications) which define what the purchaser wants and what the supplier agrees to provide, as well as quality system registration (certification) which increases confidence in the supplier`s ability to produce consistently. The requirements are typically most rigorous for regulated products that have a major impact on health and safety i.e film radiographic systems. This is the main reason for making available the necessary Q.C. tools in film radiography to comply with Q.A. specifications and guarantee the required consistent performance. These tools can only give satisfying support if they are dedicated, easy to use, precise and cost effective at the user`s level. The main topics for such a Q.A. package are: (1) standard for Film System classification for industrial radiography; (2) film system certification; and (3) standard for control of film processing by means of reference values i.e. pre-exposed film wedges and archiving quality control method.

  12. Accuracy of direct digital radiography for detecting occlusal caries in primary teeth compared with conventional radiography and visual inspection: an in vitro study

    PubMed Central

    Dias da Silva, P R; Martins Marques, M; Steagall, W; Medeiros Mendes, F; Lascala, C A

    2010-01-01

    Objectives The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen's kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. PMID:20729186

  13. Abdominal Mass Secondary to Human Toxocariasis

    PubMed Central

    Ghoroobi, Javad; Khoddami, Maliheh; Mirshemirani, Alireza; Sadeghian, Naser; Mahdavi, Alireza; Hatefi, Sayeh

    2017-01-01

    Toxocariasis is an extensive helminthic infection that leads to visceral larva migrans in humans. A 2.5-year-old girl referred for abdominal mass. She had history of pharyngitis for two weeks. There were no other symptoms. Abdominal examination revealed an irregular solid mass in right lower quadrant (RLQ). Abdominal ultrasonography revealed an echohetrogenic large mass in RLQ, liver, and retroperitoneal area. Abdominal CT scan showed a huge mass. At laparotomy a large retroperitoneal mass that involved right liver lobe, bladder, ileocecal valve, small and large intestines was found. At histopathology diagnosis of toxocariasis was made. PMID:28164001

  14. Image enhancement for radiography inspection

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Wong, Brian Stephen; Guan, Tui Chen

    2005-04-01

    The x-ray radiographic testing method is often used for detecting defects as a non-destructive testing method (NDT). In many cases, NDT is used for aircraft components, welds, etc. Hence, the backgrounds are always more complex than a piece of steel. Radiographic images are low contrast, dark and high noise image. It is difficult to detect defects directly. So, image enhancement is a significant part of automated radiography inspection system. Histogram equalization and median filter are the most frequently used techniques to enhance the radiographic images. In this paper, the adaptive histogram equalization and contrast limited histogram equalization are compared with histogram equalization. The adaptive wavelet thresholding is compared with median filter. Through comparative analysis, the contrast limited histogram equalization and adaptive wavelet thresholding can enhance perception of defects better.

  15. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    PubMed

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P < .001; 95% confidence interval [CI]: 2.96, 4.15). Case-level sensitivity was higher with tomosynthesis than with conventional chest radiography for all nodules (1.49-fold, P < .001; 95% CI: 1.25, 1.73). Case management decisions showed better overall accuracy with tomosynthesis than with conventional chest radiography, as given by the area under the receiver operating characteristic curve

  16. [Intra-abdominal mycoses].

    PubMed

    Boos, C; Kujath, P; Bruch, H-P

    2005-01-01

    The incidence of invasive mycoses in patients undergoing abdominal surgery amounts to approximately 8% and shows an upward trend in epidemiological studies. The lethality of these systemic mycoses, which are mostly based on Candida infections constitutes up to 60%. The development of a sytemic mycosis is marked by exogenic, endogenic and iatrogenic risk factors and typically displays tissue invasion after an initial fungal contamination or systemic dissemination via fungal sepsis. Fungal peritonitis is generally a monoinfection with Candida spp., where Candida albicans outweighs in 70% of cases. Aspergillus spp. are only detected abdominally in rare cases. The histological verification of a fungal invasion is regarded as proof of the existence of an invasive mycosis, but typical macroscopic findings with corresponding cultural findings can also confirm the diagnosis. Systemic mycosis requires an early initiation of a consistent antimycotic therapy as well as definitive surgical eradication of the focus in order to reduce high lethal rate. Resistances or incorrect dosages can be validated objectively by means of histological monitoring of the antimycotic therapy, thus affording early recognition of the need to change the substance class.

  17. Novel joint source-channel coding for wireless transmission of radiography images.

    PubMed

    Watanabe, Katsuhiro; Takizawa, Kenichi; Ikegami, Tetsushi

    2010-01-01

    A wireless technology is required to realize robust transmission of medical images like a radiography image over noisy environment. The use of error correction technique is essential for realizing such a reliable communication, in which a suitable channel coding is introduced to correct erroneous bits caused by passing through a noisy channel. However, the use of a channel code decreases its efficiency because redundancy bits are also transmitted with information bits. This paper presents a joint source-channel coding which maintains the channel efficiency during transmission of medical images like a radiography image. As medical images under the test, we use typical radiography images in this paper. The joint coding technique enjoys correlations between pixels of the radiography image. The results show that the proposed joint coding provides capability to correcting erroneous bits without increasing the redundancy of the codeword.

  18. Absorbed radiation by various tissues during simulated endodontic radiography

    SciTech Connect

    Torabinejad, M.; Danforth, R.; Andrews, K.; Chan, C.

    1989-06-01

    The amount of absorbed radiation by various organs was determined by placing lithium fluoride thermoluminescent chip dosimeters at selected anatomical sites in and on a human-like X-ray phantom and exposing them to radiation at 70- and 90-kV X-ray peaks during simulated endodontic radiography. The mean exposure dose was determined for each anatomical site. The results show that endodontic X-ray doses received by patients are low when compared with other radiographic procedures.

  19. Recovery after abdominal wall reconstruction.

    PubMed

    Jensen, Kristian Kiim

    2017-03-01

    implementation of the pathway. The enhanced recovery after surgery pathway included preoperative high-dose steroid, daily assessment of revised discharge criteria and an aggressive approach to restore bowel function (chewing gum and enema on postoperative day two). Patients who followed the enhanced recovery after surgery pathway reported low scores of pain, nausea and fatigue, and were discharged significantly faster than patients in the control group. A non-significant increase in postoperative readmissions and reoperations was observed after the introduction of the enhanced recovery after surgery pathway. Study III and IV were prospective studies of patients undergoing abdominal wall reconstruction for giant incisional hernia, who were compared to a control group of patients with an intact abdominal wall undergoing colorectal resection for benign or low-grade malignant disease. Patients were examined within a week preoperatively and again one year postoperatively. In study III, the respiratory function and respiratory quality of life were assessed, and the results showed that patients with a giant incisional hernia had a decreased expiratory lung function (peak expiratory flow and maximal expiratory pressure) compared to the predicted values and also compared to patients in the control group. Both parameters increased significantly after abdominal wall reconstruction, while no other significant changes were found in objective or subjective measures at one-year follow-up in both groups of patients. Lastly, study IV examined the abdominal wall- and extremity function, as well as overall and disease specific quality of life. We found that patients with a giant hernia had a significantly decreased relative function of the abdominal wall compared to patients with an intact abdominal wall, and that this deficit was offset at one-year follow-up. Patients in the control group showed a postoperative decrease in abdominal wall function, while no changes were found in extremity function

  20. Multi-purpose neutron radiography system

    SciTech Connect

    Barton, J.P.; Bryant, L.E.; Berry, P.

    1996-07-01

    A conceptual design is given for a low cost, multipurpose radiography system suited for the needs of the Los Alamos National Laboratory (LANL). The proposed neutron source is californium-252. One purpose is to provide an in-house capability for occasional, reactor quality, neutron radiography thus replacing the recently closed Omega-West Reactor. A second purpose is to provide a highly reliable standby transportable neutron radiography system. A third purpose is to provide for transportable neutron probe gamma spectroscopy techniques. The cost is minimized by shared use of an existing x-ray facility, and by use of an existing transport cask. The achievable neutron radiography and radioscopy performance characteristics have been verified. The demonstrated image qualities range from high resolution gadolinium - SR film, with L:D = 100:1, to radioscopy using a LIXI image with L:D = 30:1 and neutron fluence 3.4 x 10{sup 5} n/cm{sup 2}.

  1. Information extraction from muon radiography data

    SciTech Connect

    Borozdin, K. N.; Asaki, T. J.; Chartrand, R.; Hengartner, N. W.; Hogan, G. E.; Morris, C. L.; Priedhorsky, W. C.; Schirato, R.C.; Schultz, L. J.; Sottile, M. J.; Vixie, K. R.; Wohlberg, B. E.; Blanpied, G.

    2004-01-01

    Scattering muon radiography was proposed recently as a technique of detection and 3-d imaging for dense high-Z objects. High-energy cosmic ray muons are deflected in matter in the process of multiple Coulomb scattering. By measuring the deflection angles we are able to reconstruct the configuration of high-Z material in the object. We discuss the methods for information extraction from muon radiography data. Tomographic methods widely used in medical images have been applied to a specific muon radiography information source. Alternative simple technique based on the counting of high-scattered muons in the voxels seems to be efficient in many simulated scenes. SVM-based classifiers and clustering algorithms may allow detection of compact high-Z object without full image reconstruction. The efficiency of muon radiography can be increased using additional informational sources, such as momentum estimation, stopping power measurement, and detection of muonic atom emission.

  2. The Tribolium homeotic gene Abdominal is homologous to abdominal-A of the Drosophila bithorax complex

    NASA Technical Reports Server (NTRS)

    Stuart, J. J.; Brown, S. J.; Beeman, R. W.; Denell, R. E.; Spooner, B. S. (Principal Investigator)

    1993-01-01

    The Abdominal gene is a member of the single homeotic complex of the beetle, Tribolium castaneum. An integrated developmental genetic and molecular analysis shows that Abdominal is homologous to the abdominal-A gene of the bithorax complex of Drosophila. abdominal-A mutant embryos display strong homeotic transformations of the anterior abdomen (parasegments 7-9) to PS6, whereas developmental commitments in the posterior abdomen depend primarily on Abdominal-B. In beetle embryos lacking Abdominal function, parasegments throughout the abdomen are transformed to PS6. This observation demonstrates the general functional significance of parasegmental expression among insects and shows that the control of determinative decisions in the posterior abdomen by homeotic selector genes has undergone considerable evolutionary modification.

  3. Corrosion Inhibitors as Penetrant Dyes for Radiography

    NASA Technical Reports Server (NTRS)

    Novak, Howard L.; Hall, Phillip B.

    2003-01-01

    Liquid/vapor-phase corrosion inhibitors (LVCIs) have been found to be additionally useful as penetrant dyes for neutron radiography (and perhaps also x-radiography). Enhancement of radiographic contrasts by use of LVCIs can reveal cracks, corrosion, and other defects that may be undetectable by ultrasonic inspection, that are hidden from direct optical inspection, and/or that are difficult or impossible to detect in radiographs made without dyes.

  4. Motivations for muon radiography of active volcanoes

    NASA Astrophysics Data System (ADS)

    Macedonio, G.; Martini, M.

    2010-02-01

    Muon radiography represents an innovative tool for investigating the interior of active volcanoes. This method integrates the conventional geophysical techniques and provides an independent way to estimate the density of the volcano structure and reveal the presence of magma conduits. The experience from the pioneer experiments performed at Mt. Asama, Mt. West Iwate, and Showa-Shinzan (Japan) are very encouraging. Muon radiography could be applied, in principle, at any stratovolcano. Here we focus our attention on Vesuvius and Stromboli (Italy).

  5. Development of Compton radiography of inertial confinement fusion implosions

    SciTech Connect

    Tommasini, R.; Hatchett, S. P.; Hey, D. S.; Iglesias, C.; Izumi, N.; Koch, J. A.; Landen, O. L.; MacKinnon, A. J.; Sorce, C.; Delettrez, J. A.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C.

    2011-05-15

    An important diagnostic tool for inertial confinement fusion will be time-resolved radiographic imaging of the dense cold fuel surrounding the hot spot. The measurement technique is based on point-projection radiography at photon energies from 60 to 200 keV where the Compton effect is the dominant contributor to the opacity of the fuel or pusher. We have successfully applied this novel Compton radiography technique to the study of the final compression of directly driven plastic capsules at the OMEGA facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. The radiographs have a spatial and temporal resolution of {approx}10 {mu}m and {approx}10 ps, respectively. A statistical accuracy of {approx}0.5% in transmission per resolution element is achieved, allowing localized measurements of areal mass densities to 7% accuracy. The experimental results show 3D nonuniformities and lower than 1D expected areal densities attributed to drive asymmetries and hydroinstabilities.

  6. Proton radiography of a shock-compressed target

    SciTech Connect

    Ravasio, A.; Benuzzi-Mounaix, A.; Loupias, B.; Ozaki, N.; Vinci, T.; Koenig, M.; Romagnani, L.; Cecchetti, C.; Borghesi, M.; Le Pape, S.; Hicks, D.; MacKinnon, A.; Park, H. S.; Patel, P.; Batani, D.; Dezulian, R.; Boehly, T.; Gremillet, L.; Henry, E.; Schiavi, A.

    2010-07-15

    In this paper we report on the radiography of a shock-compressed target using laser produced proton beams. A low-density carbon foam target was shock compressed by long pulse high-energy laser beams. The shock front was transversally probed with a proton beam produced in the interaction of a high intensity laser beam with a gold foil. We show that from radiography data, the density profile in the shocked target can be deduced using Monte Carlo simulations. By changing the delay between long and short pulse beams, we could probe different plasma conditions and structures, demonstrating that the details of the steep density gradient can be resolved. This technique is validated as a diagnostic for the investigation of warm dense plasmas, allowing an in situ characterization of high-density contrasted plasmas.

  7. Lung nodules detection in chest radiography: image components analysis

    NASA Astrophysics Data System (ADS)

    Luo, Tao; Mou, Xuanqin; Yang, Ying; Yan, Hao

    2009-02-01

    We aimed to evaluate the effect of different components of chest image on performances of both human observer and channelized Fisher-Hotelling model (CFH) in nodule detection task. Irrelevant and relevant components were separated from clinical chest radiography by employing Principal Component Analysis (PCA) methods. Human observer performance was evaluated in two-alternative forced-choice (2AFC) on original clinical images and anatomical structure only images obtained by PCA methods. Channelized Fisher-Hotelling model with Laguerre-Gauss basis function was evaluated to predict human performance. We show that relevant component is the primary factor influencing on nodule detection in chest radiography. There is obvious difference of detectability between human observer and CFH model for nodule detection in images only containing anatomical structure. CFH model should be used more carefully.

  8. Development of Compton Radiography Diagnostics for Inertial Confinement Fusion Implosions

    SciTech Connect

    Tommasini, R; Hatchett, S P; Hey, D S; Izumi, N; Koch, J A; Landen, O L; Mackinnon, A J; Delettrez, J; Glebov, V; Stoeckl, C

    2010-11-16

    An important diagnostic tool for inertial confinement fusion will be time-resolved radiographic imaging of the dense cold fuel surrounding the hot spot. The measurement technique is based on point-projection radiography at photon energies from 60-200 keV where the Compton effect is the dominant contributor to the opacity of the fuel or pusher. We have successfully applied this novel Compton Radiography technique to the study of the final compression of directly driven plastic capsules at the OMEGA facility. The radiographs have a spatial and temporal resolution of {approx}10 {micro}m and {approx}10ps, respectively. A statistical accuracy of {approx}0.5% in transmission per resolution element is achieved, allowing localized measurements of areal mass densities to 7% accuracy. The experimental results show 3D non-uniformities and lower than 1D expected areal densities attributed to drive asymmetries and hydroinstabilities.

  9. Flash radiography with 24 GeV/c protons

    SciTech Connect

    Morris, C. L.; Alrick, K. R.; Buescher, K. L.; Cagliostro, D. J.; Clark, D. A.; Clark, D. J.; Espinoza, C. J.; Ferm, E. N.; Gallegos, R. A.; Gomez, J. J.; Hogan, G. E.; King, N. S. P.; Kwiatkowski, K.; Liljestrand, R. P.; Mariam, F. G.; Merrill, F. E.; Morley, K. B.; Mottershead, C. T.; Murray, M. M.; Pazuchanics, P. D.

    2011-05-15

    The accuracy of density measurements and position resolution in flash (40 ns) radiography of thick objects with 24 Gev/c protons is investigated. A global model fit to step wedge data is shown to give a good description spanning the periodic table. The parameters obtained from the step wedge data are used to predict transmission through the French Test Object (FTO), a test object of nested spheres, to a precision better than 1%. Multiple trials have been used to show that the systematic errors are less than 2%. Absolute agreement between the average radiographic measurements of the density and the known density is 1%. Spatial resolution has been measured to be 200 {mu}m at the center of the FTO. These data verify expectations of the benefits provided by high energy hadron radiography for thick objects.

  10. Proton radiography for clinical applications

    NASA Astrophysics Data System (ADS)

    Talamonti, C.; Reggioli, V.; Bruzzi, M.; Bucciolini, M.; Civinini, C.; Marrazzo, L.; Menichelli, D.; Pallotta, S.; Randazzo, N.; Sipala, V.; Cirrone, G. A. P.; Petterson, M.; Blumenkrantz, N.; Feldt, J.; Heimann, J.; Lucia, D.; Seiden, A.; Williams, D. C.; Sadrozinski, H. F.-W.; Bashkirov, V.; Schulte, R.

    2010-01-01

    Proton imaging is not yet applied as a clinical routine, although its advantages have been demonstrated. In the context of quality assurance in proton therapy, proton images can be used to verify the correct positioning of the patient and to control the range of protons. Proton computed tomography (pCT) is a 3D imaging method appropriate for planning and verification of proton radiation treatments, because it allows evaluating the distributions of proton stopping power within the tissues and can be directly utilized when the patient is in the actual treatment position. The aim of the PRoton IMAging experiment, supported by INFN, and the PRIN 2006 project, supported by MIUR, is to realize a proton computed radiography (pCR) prototype for reconstruction of proton images from a single projection in order to validate the technique with pre-clinical studies and, eventually, to conceive the configuration of a complete pCT system. A preliminary experiment performed at the 250 MeV proton synchrotron of Loma Linda University Medical Center (LLUMC) allowed acquisition of experimental data before the completion of PRIMA project's prototype. In this paper, the results of the LLUMC experiment are reported and the reconstruction of proton images of two phantoms is discussed.

  11. Mobile real time radiography system

    SciTech Connect

    Vigil, J.; Taggart, D.; Betts, S.

    1997-11-01

    A 450-keV Mobile Real Time Radiography (RTR) System was delivered to Los Alamos National Laboratory (LANL) in January 1996. It was purchased to inspect containers of radioactive waste produced at (LANL). Since its delivery it has been used to radiograph more than 600 drums of radioactive waste at various LANL sites. It has the capability of inspecting waste containers of various sizes from <1-gal. buckets up to standard waste boxes (SWB, dimensions 54.5 in. x 71 in. x 37 in.). It has three independent x-ray acquisition formats. The primary system used is a 12- in. image intensifier, the second is a 36-in. linear diode array (LDA) and the last is an open system. It is fully self contained with on board generator, HVAC, and a fire suppression system. It is on a 53-ft long x 8-ft. wide x 14-ft. high trailer that can be moved over any highway requiring only an easily obtainable overweight permit because it weights {approximately}38 tons. It was built to conform to industry standards for a cabinet system which does not require an exclusion zone. The fact that this unit is mobile has allowed us to operate where the waste is stored, rather than having to move the waste to a fixed facility.

  12. Thorium-uranium fission radiography

    NASA Technical Reports Server (NTRS)

    Haines, E. L.; Weiss, J. R.; Burnett, D. S.; Woolum, D. S.

    1976-01-01

    Results are described for studies designed to develop routine methods for in-situ measurement of the abundance of Th and U on a microscale in heterogeneous samples, especially rocks, using the secondary high-energy neutron flux developed when the 650 MeV proton beam of an accelerator is stopped in a 42 x 42 cm diam Cu cylinder. Irradiations were performed at three different locations in a rabbit tube in the beam stop area, and thick metal foils of Bi, Th, and natural U as well as polished silicate glasses of known U and Th contents were used as targets and were placed in contact with mica which served as a fission track detector. In many cases both bare and Cd-covered detectors were exposed. The exposed mica samples were etched in 48% HF and the fission tracks counted by conventional transmitted light microscopy. Relative fission cross sections are examined, along with absolute Th track production rates, interaction tracks, and a comparison of measured and calculated fission rates. The practicality of fast neutron radiography revealed by experiments to data is discussed primarily for Th/U measurements, and mixtures of other fissionable nuclei are briefly considered.

  13. [Abdominal pregnancy, institutional experience].

    PubMed

    Bonfante Ramírez, E; Bolaños Ancona, R; Simón Pereyra, L; Juárez García, L; García-Benitez, C Q

    1998-07-01

    Abdominal pregnancy is a rare entity, which has been classified as primary or secondary by Studiford criteria. A retrospective study, between January 1989 and December 1994, realized at Instituto Nacional de Perinatología, found 35,080 pregnancies, from which 149 happened to be ectopic, and 6 of them were abdominal. All patients belonged to a low income society class, age between 24 and 35 years, and average of gestations in 2.6. Gestational age varied from 15 weeks to 32.2 weeks having only one delivery at term with satisfactory postnatal evolution. One patient had a recurrent abdominal pregnancy, with genital Tb as a conditional factor. Time of hospitalization varied from 4 to 5 days, and no further patient complications were reported. Fetal loss was estimated in 83.4%. Abdominal pregnancy is often the sequence of a tubarian ectopic pregnancy an when present, it has a very high maternal mortality reported in world literature, not found in this study. The stated frequency of abdominal pregnancy is from 1 of each 3372, up to 1 in every 10,200 deliveries, reporting in the study 1 abdominal pregnancy in 5846 deliveries. The study had two characteristic entities one, the recurrence and two, the delivery at term of one newborn. Abdominal pregnancy accounts for 4% of all ectopic pregnancies. Clinical findings in abdominal pregnancies are pain, transvaginal bleeding and amenorrea, being the cardinal signs of ectopic pregnancy.

  14. WE-EF-303-04: An Advanced Image Processing Method to Improve the Spatial Resolution of Proton Radiographies

    SciTech Connect

    Rinaldi, I; Parodi, K; Krah, N

    2015-06-15

    Purpose: We present an optimization method to improve the spatial resolution and the water equivalent thickness accuracy of proton radiographies. Methods: The method is designed for imaging systems measuring only the residual range of protons without relying on tracker detectors to determine the beam trajectory before and after the target. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) working as a range telescope. The method uses a decomposition approach of the residual range signal measured by the PPIC and constructs subimages with small size pixels geometrically rearranged and appropriately averaged to be merged into a final single radiography. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. Results: For the step phantom, the effective spatial resolution was found to be 4 and 3 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed X-ray radiography convolved with a Gaussian kernel equal to the proton beam spot-size. For DTA=2.5 mm and RD=2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. An extension of the method allows reducing the dose given to the patient during radiography acquisition. We show that despite a dose reduction of 25 times (leading to a dose of 0.016 mGy for the current imaging set-up), the image quality of the optimized radiographies remains fairly unaffected for both the simulated and experimental results. Conclusion: The optimization method leads to a significant increase of the spatial resolution allowing recovering image details that are unresolved in non-optimized radiographies. These results represent a major step towards clinical

  15. Z-petawatt driven ion beam radiography development.

    SciTech Connect

    Schollmeier, Marius; Geissel, Matthias; Rambo, Patrick K.; Schwarz, Jens; Sefkow, Adam B.

    2013-09-01

    Laser-driven proton radiography provides electromagnetic field mapping with high spatiotemporal resolution, and has been applied to many laser-driven High Energy Density Physics (HEDP) experiments. Our report addresses key questions about the feasibility of ion radiography at the Z-Accelerator (%E2%80%9CZ%E2%80%9D), concerning laser configuration, hardware, and radiation background. Charged particle tracking revealed that radiography at Z requires GeV scale protons, which is out of reach for existing and near-future laser systems. However, it might be possible to perform proton deflectometry to detect magnetic flux compression in the fringe field region of a magnetized liner inertial fusion experiment. Experiments with the Z-Petawatt laser to enhance proton yield and energy showed an unexpected scaling with target thickness. Full-scale, 3D radiation-hydrodynamics simulations, coupled to fully explicit and kinetic 2D particle-in-cell simulations running for over 10 ps, explain the scaling by a complex interplay of laser prepulse, preplasma, and ps-scale temporal rising edge of the laser.

  16. Applications of Cosmic Ray Muon Radiography

    NASA Astrophysics Data System (ADS)

    Guardincerri, E.; Durham, J. M.; Morris, C. L.; Rowe, C. A.; Poulson, D. C.; Bacon, J. D.; Plaud-Ramos, K.; Morley, D. J.

    2015-12-01

    The Dome of Santa Maria del Fiore, Florence Cathedral, was built between 1420 and 1436 by architect Filippo Brunelleschi and it is now cracking under its own weight. Engineering efforts are underway to model the dome's structure and reinforce it against further deterioration. According to some scholars, Brunelleschi might have built reinforcement structures into the dome itself; however, the only confirmed known subsurface reinforcement is a chain of iron and stone around the dome's base. Tomography with cosmic ray muons is a non-destructive imaging method that can be used to image the interior of the wall and therefore ascertain the layout and status of any iron substructure in the dome. We will show the results from a muon tomography measurement of iron hidden in a mockup of the dome's wall performed at Los Alamos National Lab in 2015. The sensitivity of this technique, and the status of this project will be also discussed. At last, we will show results on muon attenuation radiography of larger shallow targets.

  17. Muon radiography for exploration of Mars geology

    NASA Astrophysics Data System (ADS)

    Kedar, S.; Tanaka, H. K. M.; Naudet, C. J.; Jones, C. E.; Plaut, J. P.; Webb, F. H.

    2013-06-01

    Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays) to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  18. Muon radiography for exploration of Mars geology

    NASA Astrophysics Data System (ADS)

    Kedar, S.; Tanaka, H. K. M.; Naudet, C. J.; Jones, C. E.; Plaut, J. P.; Webb, F. H.

    2012-10-01

    Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays) to image the interior of large scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  19. Reconstruction of large-size abdominal wall defect using biodegradable poly-p-dioxanone mesh: an experimental canine study

    PubMed Central

    2014-01-01

    Background Reconstruction of large-size abdominal wall defect (AWDs) is a huge challenge faced in current surgical practice. In this study, we aimed to evaluate the effectiveness and safety of biodegradable poly-p-dioxanone (PDO) mesh for reconstructing large-size AWDs in an experimental canine model. Methods Eighteen experimental canines were randomly and equally divided into three groups, namely, a PDO group, a Marlex group and a control group (n = 6 each). Following the creation of a 6 cm × 5.5 cm AWD, PDO mesh and Marlex mesh were used to reconstruct the defect in the PDO and Marlex groups, respectively. The defect was closed using relaxation sutures alone in the control group. Animals were killed 24 weeks after surgery, and reconstruction outcomes were evaluated using radiography, histology and biomechanical testing. Results All animals except those in the control group survived the experiment. The PDO group showed no wound dehiscence, herniation or infection, whereas the animals in the Marlex group exhibited marked foreign body reactions. The PDO group had less intraabdominal adhesion than the Marlex group. As shown by radiography, histology and biomechanical testing, PDO mesh exhibited complete degradation and favorable biochemical strength at 24 weeks postsurgery. Conclusions PDO mesh implantation is an effective, safe treatment modality for reconstructing large-size AWDs. PMID:24625138

  20. Spontaneous abscesses of the abdominal wall, omentum and abdominal cavity caused by group G streptococci: a case report.

    PubMed

    De Brabandere, K; Vanpaemel, G; Verheyen, L

    2008-01-01

    We report the first case, to our knowledge, of spontaneous abscess of the abdominal wall, omentum and abdominal cavity caused by group G streptococci. A 52-year-old diabetic woman presented with abdominal tenderness and weight loss that had persisted for a few weeks. CT scan showed several abscesses of the abdominal wall, omentum and abdominal cavity. The abscesses were drained laparoscopically and antibiotics were given postoperatively. Biopsies and cultures showed group G streptococci. The patient recovered without any complication and left our hospital on the 17th postoperative day.

  1. [Inflammatory abdominal aortic aneurysm].

    PubMed

    Ziaja, K; Sedlak, L; Urbanek, T; Kostyra, J; Ludyga, T

    2000-01-01

    The reported incidence of inflammatory abdominal aortic aneurysm (IAAA) is from 2% to 14% of patients with abdominal aortic aneurysm and the etiology of this disease is still discussed--according to the literature several pathogenic theories have been proposed. From 1992 to 1997 32 patients with IAAA were operated on. The patients were mostly symptomatic--abdominal pain was present in 68.75% cases, back pain in 31.25%, fever in 12.5% and weight loss in 6.25% of the operated patients. In all the patients ultrasound examination was performed, in 4 patients CT and in 3 cases urography. All the patients were operated on and characteristic signs of inflammatory abdominal aortic aneurysm like: thickened aortic wall, perianeurysmal infiltration or retroperitoneal fibrosis with involvement of retroperitoneal structures were found. In all cases surgery was performed using transperitoneal approach; in three cases intraoperatively contiguous abdominal organs were injured, which was connected with their involvement into periaortic inflammation. In 4 cases clamping of the aorta was done at the level of the diaphragmatic hiatus. 3 patients (9.37%) died (one patient with ruptured abdominal aortic aneurysm). Authors present diagnostic procedures and the differences in the surgical tactic, emphasizing the necessity of the surgical therapy in patients with inflammatory abdominal aortic aneurysm.

  2. Traumatic abdominal hernia complicated by necrotizing fasciitis.

    PubMed

    Martínez-Pérez, Aleix; Garrigós-Ortega, Gonzalo; Gómez-Abril, Segundo Ángel; Martí-Martínez, Eva; Torres-Sánchez, Teresa

    2014-11-01

    Necrotizing fasciitis is a critical illness involving skin and soft tissues, which may develop after blunt abdominal trauma causing abdominal wall hernia and representing a great challenge for physicians. A 52-year-old man was brought to the emergency department after a road accident, presenting blunt abdominal trauma with a large non-reducible mass in the lower-right abdomen. A first, CT showed abdominal hernia without signs of complication. Three hours after ICU admission, he developed hemodynamic instability. Therefore, a new CT scan was requested, showing signs of hernia complication. He was moved to the operating room where a complete transversal section of an ileal loop was identified. Five hours after surgery, he presented a new episode of hemodynamic instability with signs of skin and soft tissue infection. Due to the high clinical suspicion of necrotizing fasciitis development, wide debridement was performed. Following traumatic abdominal wall hernia (TAWH), patients can present unsuspected injuries in abdominal organs. Helical CT can be falsely negative in the early moments, leading to misdiagnosis. Necrotizing fasciitis is a potentially fatal infection and, consequently, resuscitation measures, wide-spectrum antibiotics, and early surgical debridement are required. This type of fasciitis can develop after blunt abdominal trauma following wall hernia without skin disruption.

  3. Thyroid dose distribution in dental radiography

    SciTech Connect

    Bristow, R.G.; Wood, R.E.; Clark, G.M. )

    1989-10-01

    The anatomic position and proven radiosensitivity of the thyroid gland make it an organ of concern in dental radiography. A calibrated thermoluminescent dosimetry system was used to investigate the absorbed dose (microGy) to the thyroid gland resultant from a minimum irradiated volume, intraoral full-mouth radiography technique with the use of rectangular collimation with a lead-backed image receptor, and conventional panoramic radiography performed with front and rear lead aprons. Use of the minimum irradiated volume technique resulted in a significantly decreased absorbed dose over the entire thyroid region ranging from 100% to 350% (p less than 0.05). Because this intraoral technique results in radiographs with greater image quality and also exposes the thyroid gland to less radiation than the panoramic, this technique may be an alternative to the panoramic procedure.

  4. The current status of panoramic radiography.

    PubMed

    Hirschmann, P N

    1987-03-01

    The current status of dental panoramic tomography (rotational panoramic radiography) is reviewed. This technique is based on a combination of tomography and slit-beam radiography to provide an image of both jaws on a single film. There is a greater degree of image degradation when compared with conventional radiographic techniques due to tomographic blurring, magnification and distortion, secondary images and burn-out. Meticulous patient position is essential to accommodate their jaws to the image layer determined by the manufacturers. The absorbed doses from panoramic radiography are of a similar order to that from bitewing radiography and lower than those from a full-mouth periapical series. The individual risk of 1.3 X 10(-6) is compared with that from other radiographic examinations and smoking. The collective risk, 1.04 deaths in the UK in 1981, is relatively insignificant as is the genetic dose. The risk to the dentist and his staff is also low compared to other risks. The methods of dose limitation currently available are reviewed. The clinical indications are considered in relation to the guidelines of the American Dental Association and the Dental Estimates Board in the UK. The problems associated with attempts to measure diagnostic yield are considered. In view of the world-wide public concern at the potential dangers of ionising radiation, dentists are urged to maximize the diagnostic yield from their panoramic radiography by taking such radiographs only when clinically necessary, ensuring meticulous positioning and processing, followed by scrupulous assessment of the radiography for any sign of pathological change.

  5. Mobile waste inspection real time radiography system

    SciTech Connect

    Vigil, J.; Taggart, D.; Betts, S.; Rael, C.; Martinez, F.; Mendez, J.

    1995-10-01

    The 450-KeV Mobile Real Time Radiography System was designed and purchased to inspect containers of radioactive waste produced at Los Alamos National Laboratory (LANL). The Mobile Real Time Radiography System has the capability of inspecting waste containers of various sizes from 5-gal. buckets to standard waste boxes (SWB, dimensions 54.5 in. x 71 in. x 37 in.). The fact that this unit is mobile makes it an attractive alternative to the costly road closures associated with moving waste from the waste generator to storage or disposal facilities.

  6. Proton Radiography: Its uses and Resolution Scaling

    SciTech Connect

    Mariam, Fesseha G.

    2012-08-09

    Los Alamos National Laboratory has used high energy protons as a probe in flash radiography for over a decade. In this time the proton radiography project has used 800 MeV protons, provided by the LANSCE accelerator facility at LANL, to diagnose over five-hundred dynamic experiments in support of stockpile stewardship programs as well as basic materials science. Through this effort significant experience has been gained in using charged particles as direct radiographic probes to diagnose transient systems. The results of this experience will be discussed through the presentation of data from experiments recently performed at the LANL pRad.

  7. Abdominal Pain Syndrome

    MedlinePlus

    ... or cancer Infection of the tubes (salpingitis) Ectopic pregnancy Fibroid tumors of the uterus (womb) Malignant tumors of the uterus or cervix Endometriosis Adhesions (scars) Screening and Diagnosis How is the cause of abdominal pain determined? ...

  8. [The abdominal catastrophe].

    PubMed

    Seiler, Christian A

    2011-08-01

    Patients with an abdominal catastrophe are in urgent need of early, interdisciplinary medical help. The treatment plan should be based on medical priorities and clear leadership. First priority should be given to achieve optimal oxygenation of blood and stabilization of circulation during all treatment-phases. The sicker the patient, the less invasive the (surgical) treatment should to be, which means "damage control only". This short article describes 7 important, pragmatic rules that will help to increase the survival of a patient with an abdominal catastrophe. Preexisting morbidity and risk factors must be included in the overall risk-evaluation for every therapeutic intervention. The challenge in patients with an abdominal catastrophe is to carefully balance the therapeutic stress and the existing resistance of the individual patient. The best way to avoid abdominal disaster, however, is its prevention.

  9. Abdominal ultrasound (image)

    MedlinePlus

    Abdominal ultrasound is a scanning technique used to image the interior of the abdomen. Like the X-ray, MRI, ... it has its place as a diagnostic tool. Ultrasound scans use high frequency sound waves to produce ...

  10. Acute abdominal pain.

    PubMed

    Stone, R

    1998-01-01

    Abdominal pain is among the most frequent ailments reported in the office setting and can account for up to 40% of ailments in the ambulatory practice. Also, it is in the top three symptoms of patients presenting to emergency departments (ED) and accounts for 5-10% of all ED primary presenting ailments. There are several common sources for acute abdominal pain and many for subacute and chronic abdominal pain. This article explores the history-taking, initial evaluation, and examination of the patient presenting with acute abdominal pain. The goal of this article is to help differentiate one source of pain from another. Discussion of acute cholecystitis, pancreatitis, appendicitis, ectopic pregnancy, diverticulitis, gastritis, and gastroenteritis are undertaken. Additionally, there is discussion of common laboratory studies, diagnostic studies, and treatment of the patient with the above entities.

  11. Abdominal and Pelvic CT

    MedlinePlus Videos and Cool Tools

    ... as ulcerative colitis or Crohn's disease , pancreatitis or liver cirrhosis. cancers of the liver, kidneys, pancreas, ovaries and bladder as well as ... injuries to abdominal organs such as the spleen, liver, kidneys or other internal organs in cases of ...

  12. Abdominal wall surgery

    MedlinePlus

    ... the results of abdominoplasty. Many feel a new sense of self-confidence. Alternative Names Cosmetic surgery of the abdomen; Tummy tuck; Abdominoplasty Images Abdominoplasty - series Abdominal muscles References McGrath MH, Pomerantz J. Plastic surgery. In: Townsend ...

  13. Californium-252: A New Isotopic Source for Neutron Radiography

    SciTech Connect

    Reinig, W.C.

    2001-08-29

    This report discusses a new isotopic source for neutron radiography, Californium-252. Nuclear reactors are the usual source of neutrons for radiography, primarily because of their intense neutron beams. If neutron radiography is to have widespread use, intense transportable neutron sources are required that can be used in plants, in laboratories and in the field.

  14. Digital radiography. A comparison with modern conventional imaging

    PubMed Central

    Bansal, G J

    2006-01-01

    The development of computed radiography over the past two decades has transformed radiological imaging. The radiology departments in the 21st century will look very different from those in the preceding period. In this review, the development of digital radiography is presented with a description of its various forms and a comparison with screen film radiography. PMID:16822918

  15. Intra-Abdominal Actinomycosis Mimicking Malignant Abdominal Disease

    PubMed Central

    Oguejiofor, Njideka; Al-Abayechi, Sarah; Njoku, Emmanuel

    2017-01-01

    Abdominal actinomycosis is a rare infectious disease, caused by gram positive anaerobic bacteria, that may appear as an abdominal mass and/or abscess (Wagenlehner et al. 2003). This paper presents an unusual case of a hemodynamically stable 80-year-old man who presented to the emergency department with 4 weeks of worsening abdominal pain and swelling. He also complains of a 20-bound weight loss in 2 months. A large tender palpable mass in the right upper quadrant was noted on physical exam. Laboratory studies showed a normal white blood cell count, slightly decreased hemoglobin and hematocrit, and mildly elevated total bilirubin and alkaline phosphatase. A CT with contrast was done and showed a liver mass. Radiology and general surgery suspected malignancy and recommended CT guided biopsy. The sample revealed abundant neutrophils and gram positive rods. Cytology was negative for malignancy and cultures eventually grew actinomyces. High dose IV penicillin therapy was given for 4 weeks and with appropriate response transitioned to oral antibiotic for 9 months with complete resolution of symptoms. PMID:28299215

  16. Abdominal involvement in tuberculosis.

    PubMed

    Neyman, Edward G; Georgiades, Christos S; Fishman, Elliot K

    2002-10-01

    Rising incidence of disseminated and extrapulmonary tuberculosis (TB), especially in immunocompromised hosts and patients with multi-drug-resistant tuberculosis, has resulted in an increase of unusual clinical and radiographic presentations of TB. With CT being a common part of emergency room (ER) evaluation of abdominal pain, it is imperative that radiologists be able to recognize abdominal presentations of TB. We discuss and illustrate typical and less common CT manifestations of tuberculosis in the abdomen to help ER radiologists in this task.

  17. Inflammatory abdominal aortic aneurysm.

    PubMed

    Savarese, R P; Rosenfeld, J C; DeLaurentis, D A

    1986-05-01

    Between January 1976 and December 1982, 181 patients with abdominal aortic aneurysms were treated surgically, and in 13 patients the aneurysms were found to be inflammatory. Inflammatory aneurysms of the abdominal aorta (IAAA) share important characteristics with typical atherosclerotic abdominal aortic aneurysms. Diagnosis and surgical management of IAAA are distinctive which suggests that IAAA should be considered separately, as a varient of typical abdominal aortic aneurysms. IAAA occur predominantly in males. The presenting symptoms are often idiosyncratic and include severe abdominal or back pain, or both, and ureteral obstruction; the diagnosis of IAAA should be considered when these symptoms are present. Although grossly and microscopically, the perianeurysmal fibrosis resembles idiopathic retroperitoneal fibrosis, the two conditions can be differentiated. At the present time, ultrasonography and computed tomography appear to offer reliable means for diagnosing IAAA. The presence of IAAA, whether established preoperatively or discovered unexpectedly at operation, necessitate certain modifications in the surgical approach, in order to avoid injuring the duodenum and the venous structures. Most patients can be successfully treated by resection and graft replacement. Rupture of the aneurysm in IAAA appears to be less frequent than in typical atherosclerotic abdominal aortic aneurysm.

  18. [Image quality and detection performance of a direct digital radiography system].

    PubMed

    Ideguchi, Tadamitsu; Matsuda, Katsuhiko; Himuro, Kazuhiko; Kuwahara, Rie; Miyazaki, Hidetsune; Hazeyama, Hiroyuki; Kumazawa, Seiji; Kawaji, Yasuyuki; Yoshida, Akira; Matsumoto, Masao; Higashida, Yoshiharu

    2006-03-20

    The physical characteristics of a direct amorphous Selenium (a-Se) digital fluoroscopy and radiography system were investigated. Pre-sampled modulation transfer functions (MTF) were measured using a slit method. Noise power spectra were determined for different input exposures by fast Fourier transform of uniformly exposed samples. The MTFs of direct digital radiography systems showed significantly higher values than those of indirect digital radiography and screen-film systems. The direct digital radiography systems showed higher noise levels compared with those of indirect systems under roughly the same exposure conditions. Contrast-detail analysis was performed to compare detection by direct digital radiography systems with that of the screen-film (FUJI HG-M2/UR2) systems. The average contrast-detail curves of digital and film images were obtained from the results of observation. Image quality figures (IQF) were also calculated from the individual observer performance tests. The results indicated that digital contrast-detail curves and IQF are, on average, are equal those of the screen-film system.

  19. Safety Testing of Industrial Radiography Devices

    SciTech Connect

    Trapp, D.J.

    1999-09-29

    The Nuclear Regulatory Commission contracted the Savannah River Technology Center to verify the relevancy of the 10 CFR Part 34 requirements for the normal use of portable gamma radiography systems and to propose recommendations for changes or modifications to the requirements.

  20. INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTORS' GUIDE. VOLUME 2.

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Engineering Extension Service.

    INFORMATION RELATIVE TO THE LESSON PLANS IN "INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTOR'S GUIDE, VOLUME I" (VT 003 565) IS PRESENTED ON 52 INFORMATION SHEETS INCLUDING THE SUBJECTS SHIELDING EQUATIONS AND LOGARITHMS, METAL PROPERTIES, FIELD TRIP INSTRUCTIONS FOR STUDENTS, WELDING SYMBOLS AND SIZES, SAMPLE REPORT FORMS, AND TYPICAL SHIPPING…

  1. Film radiography -- The lone star of quality

    SciTech Connect

    Kochakian, R.

    1995-12-31

    In this year of 1995, 100 years of x-ray photography are being celebrated. The reason film radiography is still the number one NDT technique is because of its quality. In this paper the author discusses: (1) fundamentals of image quality and (2) status of new draft ASRM film system classification standard.

  2. Variation in emergency department use of cervical spine radiography for alert, stable trauma patients

    PubMed Central

    Stiell, I G; Wells, G A; Vandemheen, K; Laupacis, A; Brison, R; Eisenhauer, M A; Greenberg, G H; MacPhail, I; McKnight, R D; Reardon, M; Verbeek, R; Worthington, J; Lesiuk, H

    1997-01-01

    number of radiographic films showing signs of abnormality was extremely low at all hospitals. The findings suggest that cervical spine radiography could be used more efficiently, possibly with the help of a clinical decision rule. PMID:9176419

  3. Diagnostic imaging of acute abdominal pain in adults.

    PubMed

    Cartwright, Sarah L; Knudson, Mark P

    2015-04-01

    Acute abdominal pain is a common presentation in the outpatient setting and can represent conditions ranging from benign to life-threatening. If the patient history, physical examination, and laboratory testing do not identify an underlying cause of pain and if serious pathology remains a clinical concern, diagnostic imaging is indicated. The American College of Radiology has developed clinical guidelines, the Appropriateness Criteria, based on the location of abdominal pain to help physicians choose the most appropriate imaging study. Ultrasonography is the initial imaging test of choice for patients presenting with right upper quadrant pain. Computed tomography (CT) is recommended for evaluating right or left lower quadrant pain. Conventional radiography has limited diagnostic value in the assessment of most patients with abdominal pain. The widespread use of CT raises concerns about patient exposure to ionizing radiation. Strategies to reduce exposure are currently being studied, such as using ultrasonography as an initial study for suspected appendicitis before obtaining CT and using low-dose CT rather than standard-dose CT. Magnetic resonance imaging is another emerging technique for the evaluation of abdominal pain that avoids ionizing radiation.

  4. Abdominal emergencies in pediatrics.

    PubMed

    Coca Robinot, D; Liébana de Rojas, C; Aguirre Pascual, E

    2016-05-01

    Abdominal symptoms are among the most common reasons for pediatric emergency department visits, and abdominal pain is the most frequently reported symptom. Thorough history taking and physical examination can often reach the correct diagnosis. Knowing the abdominal conditions that are most common in each age group can help radiologists narrow the differential diagnosis. When imaging tests are indicated, ultrasonography is usually the first-line technique, enabling the diagnosis or adding relevant information with the well-known advantages of this technique. Nowadays, plain-film X-ray studies are reserved for cases in which perforation, bowel obstruction, or foreign body ingestion is suspected. It is also important to remember that abdominal pain can also occur secondary to basal pneumonia. CT is reserved for specific indications and in individual cases, for example, in patients with high clinical suspicion of abdominal disease and inconclusive findings at ultrasonography. We review some of the most common conditions in pediatric emergencies, the different imaging tests indicated in each case, and the imaging signs in each condition.

  5. Swelling behavior detection of irradiated U-10Zr alloy fuel using indirect neutron radiography

    NASA Astrophysics Data System (ADS)

    Sun, Yong; Huo, He-yong; Wu, Yang; Li, Jiangbo; Zhou, Wei; Guo, Hai-bing; Li, Hang; Cao, Chao; Yin, Wei; Wang, Sheng; Liu, Bin; Feng, Qi-jie; Tang, Bin

    2016-11-01

    It is hopeful that fusion-fission hybrid energy system will become an effective approach to achieve long-term sustainable development of fission energy. U-10Zr alloy (which means the mass ratio of Zr is 10%) fuel is the key material of subcritical blanket for fusion-fission hybrid energy system which the irradiation performance need to be considered. Indirect neutron radiography is used to detect the irradiated U-10Zr alloy because of the high residual dose in this paper. Different burnup samples (0.1%, 0.3%, 0.5% and 0.7%) have been tested with a special indirect neutron radiography device at CMRR (China Mianyang Research Reactor). The resolution of the device is better than 50 μm and the quantitative analysis of swelling behaviors was carried out. The results show that the swelling behaviors relate well to burnup character which can be detected accurately by indirect neutron radiography.

  6. [Inflammatory abdominal aortic aneurysm].

    PubMed

    Mikami, Y; Kyogoku, M

    1994-08-01

    Inflammatory abdominal aortic aneurysm (IAAA) is a distinct clinicopathological entity, characterized by: (1) clinical presentation, such as back pain, weight loss, and increased ESR, (2) patchy and/or diffuse lymphoplasmacytic infiltration, and (3) marked periaortic fibrosis resulting in thickening of the aneurysmal wall and occasional retroperitoneal fibrosis. Its pathogenesis is unknown, but some authors support the theory that IAAA is a subtype of atherosclerotic abdominal aortic aneurysm because of close relationship between IAAA and atherosclerotic change. In this article, we describe clinical and histological features of IAAA on the basis of the literature and our review of 6 cases of IAAA, emphasizing the similarity and difference between IAAA and atherosclerotic abdominal aortic aneurysm. Our review supports that marked lamellar fibrosis completely replacing the media and adventitia, patchy lymphocytic infiltration (mostly B cells) and endarteritis obliterans are characteristic features of IAAA.

  7. Average Soil Water Retention Curves Measured by Neutron Radiography

    SciTech Connect

    Cheng, Chu-Lin; Perfect, Edmund; Kang, Misun; Voisin, Sophie; Bilheux, Hassina Z; Horita, Juske; Hussey, Dan

    2011-01-01

    Water retention curves are essential for understanding the hydrologic behavior of partially-saturated porous media and modeling flow transport processes within the vadose zone. In this paper we report direct measurements of the main drying and wetting branches of the average water retention function obtained using 2-dimensional neutron radiography. Flint sand columns were saturated with water and then drained under quasi-equilibrium conditions using a hanging water column setup. Digital images (2048 x 2048 pixels) of the transmitted flux of neutrons were acquired at each imposed matric potential (~10-15 matric potential values per experiment) at the NCNR BT-2 neutron imaging beam line. Volumetric water contents were calculated on a pixel by pixel basis using Beer-Lambert s law after taking into account beam hardening and geometric corrections. To remove scattering effects at high water contents the volumetric water contents were normalized (to give relative saturations) by dividing the drying and wetting sequences of images by the images obtained at saturation and satiation, respectively. The resulting pixel values were then averaged and combined with information on the imposed basal matric potentials to give average water retention curves. The average relative saturations obtained by neutron radiography showed an approximate one-to-one relationship with the average values measured volumetrically using the hanging water column setup. There were no significant differences (at p < 0.05) between the parameters of the van Genuchten equation fitted to the average neutron radiography data and those estimated from replicated hanging water column data. Our results indicate that neutron imaging is a very effective tool for quantifying the average water retention curve.

  8. Neutron flux mapping inside a cubic and a head PMMA phantom using indirect neutron radiography.

    PubMed

    Tsai, Pi-En; Liu, Yuan-Hao; Huang, Chun-Kai; Liu, Hong-Ming; Jiang, Shiang-Huei

    2009-07-01

    This study aims to measure the two-dimensional (2D) neutron spatial distribution inside a cubic and a head PMMA phantom for the purpose of further comparison with the treatment planning. The measurements were made by using the indirect neutron radiography (INR), which utilized a thin copper foil and the imaging plate. The developed image provides satisfactory spatial resolution and very low statistical error (< 1%). As to the time cost, the whole procedure normally takes less than 3 h. The result shows that the indirect neutron radiography can be a quick and reliable method to provide a 2D neutron spatial distribution inside a phantom.

  9. Complementary X-ray and neutron radiography study of the initial lithiation process in lithium-ion batteries containing silicon electrodes

    NASA Astrophysics Data System (ADS)

    Sun, Fu; Markötter, Henning; Manke, Ingo; Hilger, André; Alrwashdeh, Saad S.; Kardjilov, Nikolay; Banhart, John

    2017-03-01

    Complementary in operando X-ray radiography and neutron radiography measurements were conducted to investigate and visualize the initial lithiation in silicon-electrode lithium-ion batteries. By means of X-ray radiography, a significant volume expansion of Si particles and the Si electrode during the first discharge was observed. In addition, many Si particles were found that never undergo electrochemical reactions. These findings were confirmed by neutron radiography, which, for the first time, showed the process of Li alloying with the Si electrode during initial lithiation. These results demonstrate that complementary X-ray and neutron radiography is a powerful tool to investigate the lithiation mechanisms inside Si-electrode based lithium-ion batteries.

  10. Abdominal exploration - slideshow

    MedlinePlus

    ... anatomy URL of this page: //medlineplus.gov/ency/presentations/100049.htm Abdominal exploration - series—Normal anatomy To use the sharing features on this page, please enable JavaScript. Go to slide 1 out of 4 Go to slide 2 ...

  11. A system for fast neutron radiography

    SciTech Connect

    Klann, R.T.

    1996-05-01

    A system has been designed and a neutron generator installed to perform fast neutron radiography. With this sytem, objects as small as a coin or as large as a waste drum can be radiographed. The neutron source is an MF Physics A-711 neutron generator which produces 3x10{sup 10} neutrons/second with an average energy of 14.5 MeV. The radiography system uses x-ray scintillation screens and film in commercially available cassettes. The cassettes have been modified to include a thin sheet of plastic to convert neutrons to protons through elastic scattering from hydrogen and other low Z materials in the plastic. For film densities from 1.8 to 3.0, exposures range from 1.9x10{sup 7} to 3.8x10{sup 8} n/cm{sup 2} depending on the type of screen and film.

  12. Incision for abdominal laparoscopy (image)

    MedlinePlus

    Abdominal laparoscopy is a useful aid in diagnosing disease or trauma in the abdominal cavity with less scarring than ... as liver and pancreatic resections may begin with laparoscopy to exclude the presence of additional tumors (metastatic ...

  13. Digital radiography: Present detectors and future developments

    SciTech Connect

    Perez-Mendez, V.

    1990-08-01

    Present detectors for digital radiography are of two classes: real time detectors and storage (non real time) types. Present real time detectors consist of image intensifier tubes with an internal cesium iodide layer x-ray converter. Non real time detectors involve linear sweep arrays or storage detectors such as film. Future detectors discussed here can be of both types utilizing new technologies such as hydrogenated amorphous silicon photodiode arrays coupled to thin film transistor arrays. 17 refs., 10 figs.

  14. Abdominal Pain Caused by a Potentially Fatal Attraction.

    PubMed

    Mercurio, Danielle Claire; Scace, Candace; Shah, Bhairav; Weiner, Evan; Prasad, Rajeev

    2016-11-19

    Abdominal pain is a challenging presentation in children. Examination findings and etiology vary greatly, spanning a vast spectrum from flatulence to frank peritonitis with septic shock. Here, we discuss a 10-year-old boy with 24 hours of progressively worsening lower abdominal pain, nausea, and subjective fevers. History and physical examination findings were consistent with appendicitis. However, physicians were surprised when the single-view abdominal radiograph showed an unanticipated, somewhat perplexing discovery.

  15. Dual energy scanning beam X-radiography

    NASA Astrophysics Data System (ADS)

    Wojcik, Randolph Frank

    Dual energy X-radiography is a method first developed in the mid-1970's by which one uses the information contained in the energy spectrum of the transmitted X-ray flux through an object. With this information one can distinguish the types of materials present in a radiograph and thus allow a computer to subtract them from the image enhancing the contrast of the remaining materials. Using this method, one can see details, which would have been hidden by overlying structures of other materials such as seen in radiographs of parts, made up of mixtures of metals and composites. There is also great interest in this technique for medical imaging of the chest where images of the organs are significantly improved by subtracting the bones. However, even with the enhanced capabilities realized with this technique, the majority of X-radiography systems only measures the bulk transmitted X-ray intensity and ignores the information contained in the energy spectrum. This is due to the added expense, time requirements, and registration problems incurred using standard radiographic methods to obtain dual energy radiographs. This dissertation describes a novel method which overcomes these problems and allows one to perform inexpensive, near real time, single shot dual energy X-radiography. The work of this thesis resulted in US patent #5,742,660.

  16. An Experimental Study for Minimum Level of Decalcification to Detect the Osteolytic Bone Metastasis of Long Bone on Plain Radiography

    PubMed Central

    Baek, Jun Ho; Seo, Sung Hwa

    2016-01-01

    Background In 1951, Ardran reported that metastatic bone lesions could be detectable on plain radiography with 30% to 50% of decalcification. Authors performed experimental study for minimum level of decalcification to detect the osteolytic bone metastasis of long bone with recent technique of radiographs. Methods One pair of fibula and humerus from two cadavers was cut into specimen 1 inch in length. Distal half of specimen was dipped into hydrochloride (HCl) with 15 min interval. All 16 specimens were checked by film-type radiography (FR), computed radiography (CR), digital radiography (DR). To exclude inter-observer's variance, 3 radiologists evaluated images. Calcium amount before and after decalcification was measured and expressed in percentage of decalcification. Results Osteolytic changes were detectable with 11% to 16% of decalcification for fibula and 3% to 8% for humerus on plain radiography with FR, CR, and DR. Conclusions Our study showed that minimum of 3% and maximum of 16% of decalcification is necessary when osteolytic metastatic bone lesions of long bone could be detected on plain radiography. PMID:27622177

  17. [Myxofibrosarcoma in the abdominal cavity].

    PubMed

    Janů, F

    2016-01-01

    A number of benign and malignant tumors may develop in the abdominal cavity. Sarcomas are rather rare tumors of the abdominal cavity. They are often diagnosed at advanced growth stages as their local growth can cause clinical problems to the patients. The author presents a case report of myxofibrosarcoma in the abdominal cavity.Key words: myxofibrosarcoma.

  18. Emergency skull radiography: the effect of restrictive criteria on skull radiography and CT use

    SciTech Connect

    Baker, S.R.; Gaylord, G.M.; Lantos, G.; Tabaddor, K.; Gallagher, E.J.

    1985-08-01

    A prospective study was performed to determine the effect of restrictive criteria on the use of emergency skull radiography and computed tomography (CT) of the head. Emergency skull radiography required the completion of a special requisition form. Emergency CT of the head was done at the request of senior consultants and was available on a full-time basis. Over 1 year, 2758 skull studies were performed, a decrease of 39.1% when compared with the year before restrictive criteria were instituted, during which 4587 skull examinations were done. In the same period, the number of emergency CT scans of the head increased by 45.7%, from 471 in the control year to 686 in the experimental year. With the use of restrictive criteria, a net savings of $164,000 was achieved. Our results suggest that the use of restrictive criteria is a cost-effective means of limiting skull radiography when CT of the head is readily available.

  19. Inverse-collimated proton radiography for imaging thin materials

    NASA Astrophysics Data System (ADS)

    Freeman, Matthew S.; Allison, Jason; Andrews, Malcolm; Ferm, Eric; Goett, John J.; Kwiatkowski, Kris; Lopez, Julian; Mariam, Fesseha; Marr-Lyon, Mark; Martinez, Michael; Medina, Jason; Medina, Patrick; Merrill, Frank E.; Morris, Chris L.; Murray, Matthew M.; Nedrow, Paul; Neukirch, Levi P.; Prestridge, Katherine; Rigg, Paolo; Saunders, Alexander; Schurman, Tamsen; Tainter, Amy; Trouw, Frans; Tupa, Dale; Tybo, Josh; Vogan-McNeil, Wendy; Wilde, Carl

    2017-01-01

    Relativistic, magnetically focused proton radiography was invented at Los Alamos National Laboratory using the 800 MeV LANSCE beam and is inherently well-suited to imaging dense objects, at areal densities >20 g cm-2. However, if the unscattered portion of the transmitted beam is removed at the Fourier plane through inverse-collimation, this system becomes highly sensitive to very thin media, of areal densities <100 mg cm-2. Here, this inverse-collimation scheme is described in detail and demonstrated by imaging Xe gas with a shockwave generated by an aluminum plate compressing the gas at Mach 8.8. With a 5-mrad inverse collimator, an areal density change of just 49 mg cm-2 across the shock front is discernible with a contrast-to-noise ratio of 3. Geant4 modeling of idealized and realistic proton transports can guide the design of inverse-collimators optimized for specific experimental conditions and show that this technique performs better for thin targets with reduced incident proton beam emittance. This work increases the range of areal densities to which the system is sensitive to span from ˜25 mg cm-2 to 100 g cm-2, exceeding three orders of magnitude. This enables the simultaneous imaging of a dense system as well as thin jets and ejecta material that are otherwise difficult to characterize with high-energy proton radiography.

  20. Inverse-collimated proton radiography for imaging thin materials.

    PubMed

    Freeman, Matthew S; Allison, Jason; Andrews, Malcolm; Ferm, Eric; Goett, John J; Kwiatkowski, Kris; Lopez, Julian; Mariam, Fesseha; Marr-Lyon, Mark; Martinez, Michael; Medina, Jason; Medina, Patrick; Merrill, Frank E; Morris, Chris L; Murray, Matthew M; Nedrow, Paul; Neukirch, Levi P; Prestridge, Katherine; Rigg, Paolo; Saunders, Alexander; Schurman, Tamsen; Tainter, Amy; Trouw, Frans; Tupa, Dale; Tybo, Josh; Vogan-McNeil, Wendy; Wilde, Carl

    2017-01-01

    Relativistic, magnetically focused proton radiography was invented at Los Alamos National Laboratory using the 800 MeV LANSCE beam and is inherently well-suited to imaging dense objects, at areal densities >20 g cm(-2). However, if the unscattered portion of the transmitted beam is removed at the Fourier plane through inverse-collimation, this system becomes highly sensitive to very thin media, of areal densities <100 mg cm(-2). Here, this inverse-collimation scheme is described in detail and demonstrated by imaging Xe gas with a shockwave generated by an aluminum plate compressing the gas at Mach 8.8. With a 5-mrad inverse collimator, an areal density change of just 49 mg cm(-2) across the shock front is discernible with a contrast-to-noise ratio of 3. Geant4 modeling of idealized and realistic proton transports can guide the design of inverse-collimators optimized for specific experimental conditions and show that this technique performs better for thin targets with reduced incident proton beam emittance. This work increases the range of areal densities to which the system is sensitive to span from ∼25 mg cm(-2) to 100 g cm(-2), exceeding three orders of magnitude. This enables the simultaneous imaging of a dense system as well as thin jets and ejecta material that are otherwise difficult to characterize with high-energy proton radiography.

  1. Toward practical 3D radiography of pipeline girth welds

    SciTech Connect

    Wassink, Casper

    2015-03-31

    Digital radiography has made its way into in-the-field girth weld testing. With recent generations of detectors and x-ray tubes it is possible to reach the image quality desired in standards as well as the speed of inspection desired to be competitive with film radiography and automated ultrasonic testing. This paper will show the application of these technologies in the RTD Rayscan system. The method for achieving an image quality that complies with or even exceeds prevailing industrial standards will be presented, as well as the application on pipeline girth welds with CRA layers. A next step in development will be to also achieve a measurement of weld flaw height to allow for performing an Engineering Critical Assessment on the weld. This will allow for similar acceptance limits as currently used with Automated Ultrasonic Testing of pipeline girth welds. Although a sufficient sizing accuracy was already demonstrated and qualified in the TomoCAR system, testing in some applications is restricted to time limits. The paper will present some experiments that were performed to achieve flaw height approximation within these time limits.

  2. Using Digital Radiography To Image Liquid Nitrogen in Voids

    NASA Technical Reports Server (NTRS)

    Cox, Dwight; Blevins, Elana

    2007-01-01

    Digital radiography by use of (1) a field-portable x-ray tube that emits low-energy x rays and (2) an electronic imaging x-ray detector has been found to be an effective technique for detecting liquid nitrogen inside voids in thermal-insulation panels. The technique was conceived as a means of investigating cryopumping (including cryoingestion) as a potential cause of loss of thermal insulation foam from space-shuttle external fuel tanks. The technique could just as well be used to investigate cryopumping and cryoingestion in other settings. In images formed by use of low-energy x-rays, one can clearly distinguish between voids filled with liquid nitrogen and those filled with gaseous nitrogen or other gases. Conventional film radiography is of some value, but yields only non-real-time still images that do not show time dependences of levels of liquids in voids. In contrast, the present digital radiographic technique yields a succession of images in real time at a rate of about 10 frames per second. The digitized images can be saved for subsequent analysis to extract data on time dependencies of levels of liquids and, hence, of flow paths and rates of filling and draining. The succession of images also amounts to a real-time motion picture that can be used as a guide to adjustment of test conditions.

  3. Toward practical 3D radiography of pipeline girth welds

    NASA Astrophysics Data System (ADS)

    Wassink, Casper; Hol, Martijn; Flikweert, Arjan; van Meer, Philip

    2015-03-01

    Digital radiography has made its way into in-the-field girth weld testing. With recent generations of detectors and x-ray tubes it is possible to reach the image quality desired in standards as well as the speed of inspection desired to be competitive with film radiography and automated ultrasonic testing. This paper will show the application of these technologies in the RTD Rayscan system. The method for achieving an image quality that complies with or even exceeds prevailing industrial standards will be presented, as well as the application on pipeline girth welds with CRA layers. A next step in development will be to also achieve a measurement of weld flaw height to allow for performing an Engineering Critical Assessment on the weld. This will allow for similar acceptance limits as currently used with Automated Ultrasonic Testing of pipeline girth welds. Although a sufficient sizing accuracy was already demonstrated and qualified in the TomoCAR system, testing in some applications is restricted to time limits. The paper will present some experiments that were performed to achieve flaw height approximation within these time limits.

  4. Assessing The Impact Of Computed Radiography And PACS

    NASA Astrophysics Data System (ADS)

    Hedgcock, Marcus W.; Kehr, Katherine

    1989-05-01

    Our institution (San Francisco VA Medical Center) is a VA pilot center for total digital imaging and PACS. Quantitative information about PACS impact on health care is limited, because no centers have done rigorous preimplementation studies. We are gathering quantitative service delivery and cost data before, during, and after stepwise implementation of computed radiography and PACS at our institution to define the impact on imaging service delivery. We designed a simple audit method using the x-ray request and time clocks to determine patient waiting time, imaging time, film use, image availability to the radiologist, matching of current with previous images, image availability to clinicians, and time to final interpretation. Our department model is a multichannel, mulitserver patient queue. Our current radiograph file is space limited, containing only one year of images; older images are kept in a remote file area in another building. In addition, there are 16 subfile areas within the Radiology Service and the medical center. Our preimplementation audit showed some long waiting times (40 minutes, average 20) and immediate retrieval of prior films in only 42% of cases, with an average retrieval time of 22 hours. Computed radiography and the optical archive have the potential to improve these figures. The audit will be ongoing and automated as implementation of PACS progresses, to measure service improvement and learning curve with the new equipment. We present the audit format and baseline preimplementation figures.

  5. Building a cost efficient digital radiography system for educational purposes

    NASA Astrophysics Data System (ADS)

    Brown, Chris

    Due to the growing need for Medical Physicists, many universities are implementing a Medical Physics program into their academic catalog. To help establish a new program, feasible equipment may be needed to help academic departments provide a hands-on experience for students and help teach the basic concepts of Medical Physics. For example, clinical Digital Radiography Systems (DRS) are used to help teach the basic concepts of digital imaging. However, such systems can cost in excess of 100,000, creating a financial obstacle that will be difficult to overcome. Hence, the development of a cost efficient digital radiography system may be desired in order to eliminate the financial obstacle and give students a hands-on learning experience. This DRS uses three main components to develop an image, an x-ray source, an intensifying plate, and a charge-coupled device (CCD) camera. All three components are housed in a lead-lined box. The purpose of this project is to find the limitations of our DRS and compare the price between our DRS and commercially available DRSs. At optimal settings, a SNR of 25 is shown across the intensifying screen that can identify objects as small as 0.42mm. A Contrast-detail phantom shows the ability to decipher the varying thickness of foam rubber squares. The total cost of our DRS comes to 17,000.00, a fractional price tag compared to a commercially available DRS.

  6. Vertically transmitted hypoplasia of the abdominal wall musculature.

    PubMed

    Chan, Yuin-Chew; Bird, Lynne M

    2004-01-01

    The prune belly syndrome (OMIM 100100) is an association of bladder dilation with hypoplasia of the abdominal wall muscles. This malformation sequence is due to early urethral obstruction. We report a family with abdominal wall muscular hypoplasia as an isolated defect, not associated with the urethral obstruction sequence. The proband is a q3-year-old male who presented with abdominal wall laxity and severe constipation. His mother, maternal grandmother and younger brother had varying degrees of abdominal wall muscular deficiency and constipation. His mother's condition was aggravated by her 2 pregnancies. This family shows vertical transmission (compatible with autosomal dominant or mitochondrial inheritance) of the abdominal phenotype of prune belly sequence without any evidence of urinary tract or renal pathology. The expression in the sons may remain incomplete because abdominal distention due to pregnancy will not occur.

  7. "The Show"

    ERIC Educational Resources Information Center

    Gehring, John

    2004-01-01

    For the past 16 years, the blue-collar city of Huntington, West Virginia, has rolled out the red carpet to welcome young wrestlers and their families as old friends. They have come to town chasing the same dream for a spot in what many of them call "The Show". For three days, under the lights of an arena packed with 5,000 fans, the…

  8. Abdomen X-Ray (Radiography)

    MedlinePlus

    ... examined, an x-ray machine produces a small burst of radiation that passes through the body, recording ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ...

  9. Ruptured abdominal aortic aneurysm.

    PubMed

    Sachs, T; Schermerhorn, M

    2010-06-01

    Ruptured abdominal aortic aneurysm (AAA) continues to be one of the most lethal vascular pathologies we encounter. Its management demands prompt and efficient evaluation and repair. Open repair has traditionally been the mainstay of treatment. However, the introduction of endovascular techniques has altered the treatment algorithm for ruptured AAA in most major medical centers. We present recent literature and techniques for ruptured AAA and its surgical management.

  10. The Abdominal Circulatory Pump

    PubMed Central

    Aliverti, Andrea; Bovio, Dario; Fullin, Irene; Dellacà, Raffaele L.; Lo Mauro, Antonella; Pedotti, Antonio; Macklem, Peter T.

    2009-01-01

    Blood in the splanchnic vasculature can be transferred to the extremities. We quantified such blood shifts in normal subjects by measuring trunk volume by optoelectronic plethysmography, simultaneously with changes in body volume by whole body plethysmography during contractions of the diaphragm and abdominal muscles. Trunk volume changes with blood shifts, but body volume does not so that the blood volume shifted between trunk and extremities (Vbs) is the difference between changes in trunk and body volume. This is so because both trunk and body volume change identically with breathing and gas expansion or compression. During tidal breathing Vbs was 50–75 ml with an ejection fraction of 4–6% and an output of 750–1500 ml/min. Step increases in abdominal pressure resulted in rapid emptying presumably from the liver with a time constant of 0.61±0.1SE sec. followed by slower flow from non-hepatic viscera. The filling time constant was 0.57±0.09SE sec. Splanchnic emptying shifted up to 650 ml blood. With emptying, the increased hepatic vein flow increases the blood pressure at its entry into the inferior vena cava (IVC) and abolishes the pressure gradient producing flow between the femoral vein and the IVC inducing blood pooling in the legs. The findings are important for exercise because the larger the Vbs the greater the perfusion of locomotor muscles. During asystolic cardiac arrest we calculate that appropriate timing of abdominal compression could produce an output of 6 L/min. so that the abdominal circulatory pump might act as an auxiliary heart. PMID:19440240

  11. Lateral Abdominal Wall Reconstruction

    PubMed Central

    Baumann, Donald P.; Butler, Charles E.

    2012-01-01

    Lateral abdominal wall (LAW) defects can manifest as a flank hernias, myofascial laxity/bulges, or full-thickness defects. These defects are quite different from those in the anterior abdominal wall defects and the complexity and limited surgical options make repairing the LAW a challenge for the reconstructive surgeon. LAW reconstruction requires an understanding of the anatomy, physiologic forces, and the impact of deinnervation injury to design and perform successful reconstructions of hernia, bulge, and full-thickness defects. Reconstructive strategies must be tailored to address the inguinal ligament, retroperitoneum, chest wall, and diaphragm. Operative technique must focus on stabilization of the LAW to nonyielding points of fixation at the anatomic borders of the LAW far beyond the musculofascial borders of the defect itself. Thus, hernias, bulges, and full-thickness defects are approached in a similar fashion. Mesh reinforcement is uniformly required in lateral abdominal wall reconstruction. Inlay mesh placement with overlying myofascial coverage is preferred as a first-line option as is the case in anterior abdominal wall reconstruction. However, interposition bridging repairs are often performed as the surrounding myofascial tissue precludes a dual layered closure. The decision to place bioprosthetic or prosthetic mesh depends on surgeon preference, patient comorbidities, and clinical factors of the repair. Regardless of mesh type, the overlying soft tissue must provide stable cutaneous coverage and obliteration of dead space. In cases where the fasciocutaneous flaps surrounding the defect are inadequate for closure, regional pedicled flaps or free flaps are recruited to achieve stable soft tissue coverage. PMID:23372458

  12. Abdominal SPECT imaging

    SciTech Connect

    Van Heertum, R.L.; Brunetti, J.C.; Yudd, A.P.

    1987-07-01

    Over the past several years, abdominal single photon emission computed tomography (SPECT) imaging has evolved from a research tool to an important clinical imaging modality that is helpful in the diagnostic assessment of a wide variety of disorders involving the abdominal viscera. Although liver-spleen imaging is the most popular of the abdominal SPECT procedures, blood pool imaging is becoming much more widely utilized for the evaluation of cavernous hemangiomas of the liver as well as other vascular abnormalities in the abdomen. Adjunctive indium leukocyte and gallium SPECT studies are also proving to be of value in the assessment of a variety of infectious and neoplastic diseases. As more experience is acquired in this area, SPECT should become the primary imaging modality for both gallium and indium white blood cells in many institutions. Renal SPECT, on the other hand, has only recently been used as a clinical imaging modality for the assessment of such parameters as renal depth and volume. The exact role of renal SPECT as a clinical tool is, therefore, yet to be determined. 79 references.

  13. Abdominal emergencies during pregnancy.

    PubMed

    Bouyou, J; Gaujoux, S; Marcellin, L; Leconte, M; Goffinet, F; Chapron, C; Dousset, B

    2015-12-01

    Abdominal emergencies during pregnancy (excluding obstetrical emergencies) occur in one out of 500-700 pregnancies and may involve gastrointestinal, gynecologic, urologic, vascular and traumatic etiologies; surgery is necessary in 0.2-2% of cases. Since these emergencies are relatively rare, patients should be referred to specialized centers where surgical, obstetrical and neonatal cares are available, particularly because surgical intervention increases the risk of premature labor. Clinical presentations may be atypical and misleading because of pregnancy-associated anatomical and physiologic alterations, which often result in diagnostic uncertainty and therapeutic delay with increased risks of maternal and infant morbidity. The most common abdominal emergencies are acute appendicitis (best treated by laparoscopic appendectomy), acute calculous cholecystitis (best treated by laparoscopic cholecystectomy from the first trimester through the early part of the third trimester) and intestinal obstruction (where medical treatment is the first-line approach, just as in the non-pregnant patient). Acute pancreatitis is rare, usually resulting from trans-ampullary passage of gallstones; it usually resolves with medical treatment but an elevated risk of recurrent episodes justifies laparoscopic cholecystectomy in the 2nd trimester and endoscopic sphincterotomy in the 3rd trimester. The aim of the present work is to review pregnancy-induced anatomical and physiological modifications, to describe the main abdominal emergencies during pregnancy, their specific features and their diagnostic and therapeutic management.

  14. A new x-ray imaging technique for radiography mode of flat-panel imager

    NASA Astrophysics Data System (ADS)

    Suzuki, K.; Ikeda, S.; Ueda, K.; Baba, R.

    2007-03-01

    A digital radiography system using a flat-panel imager, which has a novel imaging technique for a radiography mode, has been developed. A radiographic image captured by the new imaging technique has a wide dynamic range in comparison with conventional radiographic images. The purpose of this presentation is to show the basic performance of the image quality acquired by the new imaging technique and compare it with an image taken by a conventional technique. The flat-panel imager has a gain switching capability, normally used in a dynamic imaging mode for a cone-beam CT study. The gain switching method has two gain settings and switches between them automatically, depending on the incident dose to each pixel of flat-panel imager. As a result of the gain switching method, an image having wide dynamic range is achieved. In this study, we applied the gain switching method to the radiography mode, and achieved a radiographic image with wider dynamic range than a conventional radiograph. Furthermore, we have also developed an algorithm for calibration of the gain switching method in radiography mode.

  15. THE USE OF DIGITAL RADIOGRAPHY IN THE EVALUATION OF RADIOACTIVE MATERIALS PACKAGING PERFORMANCE TESTING

    SciTech Connect

    May, C; Lawrence Gelder, L; Boyd Howard, B

    2007-03-22

    New designs of radioactive material shipping packages are required to be evaluated in accordance with 10 CFR Part 71, ''Packaging and Transportation of Radioactive Material''. This paper will discuss the use of digital radiography to evaluate the effects of the tests required by 10 CFR 71.71, Normal Conditions of Transport (NCT), and 10 CFR 71.73, Hypothetical Accident Conditions (HAC). One acceptable means of evaluating packaging performance is to subject packagings to the series of NCT and HAC tests. The evaluation includes a determination of the effect on the packaging by the conditions and tests. That determination has required that packagings be cut and sectioned to learn the actual effects on internal components. Digital radiography permits the examination of internal packaging components without sectioning a package. This allows a single package to be subjected to a series of tests. After each test, the package is digitally radiographed and the effects of particular tests evaluated. Radiography reduces the number of packages required for testing and also reduces labor and materials required to section and evaluate numerous packages. This paper will include a description of the digital radiography equipment used in the testing and evaluation of the 9977 and 9978 packages at SRNL. The equipment is capable of making a single radiograph of a full-sized package in one exposure. Radiographs will be compared to sectioned packages that show actual conditions compared to radiographic images.

  16. Axial Tomography from Digitized Real Time Radiography

    DOE R&D Accomplishments Database

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  17. Digital Radiography Qualification of Tube Welding

    NASA Technical Reports Server (NTRS)

    Carl, Chad

    2012-01-01

    The Orion Project will be directing Lockheed Martin to perform orbital arc welding on commodities metallic tubing as part of the Multi Purpose Crew Vehicle assembly and integration process in the Operations and Checkout High bay at Kennedy Space Center. The current method of nondestructive evaluation is utilizing traditional film based x-rays. Due to the high number of welds that are necessary to join the commodities tubing (approx 470), a more efficient and expeditious method of nondestructive evaluation is desired. Digital radiography will be qualified as part of a broader NNWG project scope.

  18. Axial tomography from digitized real time radiography

    SciTech Connect

    Zolnay, A.S.; McDonald, W.M.; Doupont, P.A.; McKinney, R.L.; Lee, M.M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  19. Diagnostics of coated fuel particles by neutron and synchrotron radiography

    SciTech Connect

    Momot, G. V.; Podurets, K. M.; Pogorelyi, D. K.; Somenkov, V. A.; Yakovenko, E. V.

    2011-12-15

    The nondestructive monitoring of coated fuel particles has been performed using contact neutron radiography and refraction radiography based on synchrotron radiation. It is shown that these methods supplement each other and have a high potential for determining the sizes, densities, and isotopic composition of the particle components.

  20. Advances in digital radiography: physical principles and system overview.

    PubMed

    Körner, Markus; Weber, Christof H; Wirth, Stefan; Pfeifer, Klaus-Jürgen; Reiser, Maximilian F; Treitl, Marcus

    2007-01-01

    During the past two decades, digital radiography has supplanted screen-film radiography in many radiology departments. Today, manufacturers provide a variety of digital imaging solutions based on various detector and readout technologies. Digital detectors allow implementation of a fully digital picture archiving and communication system, in which images are stored digitally and are available anytime. Image distribution in hospitals can now be achieved electronically by means of web-based technology with no risk of losing images. Other advantages of digital radiography include higher patient throughput, increased dose efficiency, and the greater dynamic range of digital detectors with possible reduction of radiation exposure to the patient. The future of radiography will be digital, and it behooves radiologists to be familiar with the technical principles, image quality criteria, and radiation exposure issues associated with the various digital radiography systems that are currently available.

  1. Using ytterbium-169 for safe and economical industrial radiography

    SciTech Connect

    Dowalo, J.A.

    1994-01-01

    Safety has become an issue of paramount importance for industrial radiography. Many NDE facilities and suppliers are finding the cost of performing radiography Prohibitive due to heightened safety concerns for radiation area protection. The most common sources used in radiography, Iridium-192 and Cobalt-60, result in high radiation fields over a large area. Even when collimators are used large radiation fields can result from multicurie source radiography. Radiographic operations are being forced to find alternative test methods and techniques to the use of the old stand-by sources. These alternate methods are not always as comprehensive a test as full volumetric examination with radiography. Since Iridium and Cobalt are in such wide spread use, they are sometimes called upon to perform test of materials which are not in their optimum sensitivity range.

  2. Simulation of computed radiography with imaging plate detectors

    SciTech Connect

    Tisseur, D.; Costin, M.; Mathy, F.; Schumm, A.

    2014-02-18

    Computed radiography (CR) using phosphor imaging plate detectors is taking an increasing place in Radiography Testing. CR uses similar equipment as conventional radiography except that the classical X-ray film is replaced by a numerical detector, called image plate (IP), which is made of a photostimulable layer and which is read by a scanning device through photostimulated luminescence. Such digital radiography has already demonstrated important benefits in terms of exposure time, decrease of source energies and thus reduction of radioprotection area besides being a solution without effluents. This paper presents a model for the simulation of radiography with image plate detectors in CIVA together with examples of validation of the model. The study consists in a cross comparison between experimental and simulation results obtained on a step wedge with a classical X-ray tube. Results are proposed in particular with wire Image quality Indicator (IQI) and duplex IQI.

  3. Neutron radiography of irradiated nuclear fuel at Idaho National Laboratory

    SciTech Connect

    Craft, Aaron E.; Wachs, Daniel M.; Okuniewski, Maria A.; Chichester, David L.; Williams, Walter J.; Papaioannou, Glen C.; Smolinski, Andrew T.

    2015-09-10

    Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Idaho National Laboratory (INL) has multiple nuclear fuels research and development programs that routinely evaluate irradiated fuels using neutron radiography. The Neutron Radiography reactor (NRAD) sits beneath a shielded hot cell facility where neutron radiography and other evaluation techniques are performed on these highly radioactive objects. The NRAD currently uses the foil-film transfer technique for imaging fuel that is time consuming but provides high spatial resolution. This study describes the NRAD and hot cell facilities, the current neutron radiography capabilities available at INL, planned upgrades to the neutron imaging systems, and new facilities being brought online at INL related to neutron imaging.

  4. Neutron Radiography of Irradiated Nuclear Fuel at Idaho National Laboratory

    NASA Astrophysics Data System (ADS)

    Craft, Aaron E.; Wachs, Daniel M.; Okuniewski, Maria A.; Chichester, David L.; Williams, Walter J.; Papaioannou, Glen C.; Smolinski, Andrew T.

    Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Idaho National Laboratory (INL) has multiple nuclear fuels research and development programs that routinely evaluate irradiated fuels using neutron radiography. The Neutron Radiography reactor (NRAD) sits beneath a shielded hot cell facility where neutron radiography and other evaluation techniques are performed on these highly radioactive objects. The NRAD currently uses the foil-film transfer technique for imaging fuel that is time consuming but provides high spatial resolution. This paper describes the NRAD and hot cell facilities, the current neutron radiography capabilities available at INL, planned upgrades to the neutron imaging systems, and new facilities being brought online at INL related to neutron imaging.

  5. Neutron radiography of irradiated nuclear fuel at Idaho National Laboratory

    DOE PAGES

    Craft, Aaron E.; Wachs, Daniel M.; Okuniewski, Maria A.; ...

    2015-09-10

    Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Idaho National Laboratory (INL) has multiple nuclear fuels research and development programs that routinely evaluate irradiated fuels using neutron radiography. The Neutron Radiography reactor (NRAD) sits beneath a shielded hot cell facility where neutron radiography and other evaluation techniques are performed on these highly radioactive objects. The NRAD currently uses the foil-film transfer technique for imaging fuel that is time consuming but provides high spatial resolution. This study describes the NRAD and hot cell facilities,more » the current neutron radiography capabilities available at INL, planned upgrades to the neutron imaging systems, and new facilities being brought online at INL related to neutron imaging.« less

  6. Abdominal perfusion computed tomography.

    PubMed

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-02-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis.

  7. Abdominal Perfusion Computed Tomography

    PubMed Central

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M. Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-01-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis. PMID:25610249

  8. Bone Texture Characterization for Osteoporosis Diagnosis using Digital Radiography

    PubMed Central

    Zheng, Keni; Makrogiannis, Sokratis

    2017-01-01

    We introduce texture classification techniques to effectively diagnose osteoporosis in bone radiography data. Osteoporosis is an age-related systemic bone skeletal disorder characterized by low bone mass and bone structure deterioriation that results in increased bone fragility and higher fracture risk. Therefore, early diagnosis can effectively predict fracture risk and prevent the disease. Automated diagnosis from digital radiographs is very challenging since the scans of healthy and osteoporotic subjects show little or no visual differences, and their density histograms mostly overlap. We designed a system to separate healthy from osteoporotic subjects using high-dimensional textural feature representations computed from radiographs. These features were then reduced using feature selection to obtain the more discriminant subset that was finally classified by our methods. The top performing approach yields 79.3% accuracy and 81% area under the ROC over 116 bone radiographs. PMID:28268501

  9. Recurrent pneumothorax following abdominal paracentesis.

    PubMed Central

    Stafford, P. J.

    1990-01-01

    A 62 year old man presented with abdominal ascites, without pleural effusion, due to peritoneal mesothelioma. He had chronic obstructive airways disease and a past history of right upper lobectomy for tuberculosis. On two occasions abdominal paracentesis was followed within 72 hours by pneumothorax. This previously unreported complication of abdominal paracentesis may be due to increased diaphragmatic excursion following the procedure and should be considered in patients with preexisting lung disease. PMID:2385561

  10. Abdominal Tuberculosis in Cairo, Egypt

    DTIC Science & Technology

    1994-01-01

    COW 03 PUBLICATION REPORT 94-30227 * ABDOMINAL TUBERCULOSIS IN CAIRO, BY RWIavni 0. IHibbs6 M. Kuanmm ad Z. Fun .Y .~ ... W I Form ApprovedREPORT...Leave blank) 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED 8 April 1993 4. TITLE AND SUBTITLE S. FUNDING NUMBERS Abdominal Tuberculosis in Cairo...abdominal tuberculosis patients seen at Abbassia Fever Hospital in Cairo, Egypt from January 1990 to August 1992 are described; their mean age was 21.5

  11. Abdominal pregnancy- a case report.

    PubMed

    Okafor, Ii; Ude, Ac; Aderibigbe, Aso; Amu, Oc; Udeh, Pe; Obianyo, Nen; Ani, Coc

    2011-01-01

    A case of abdominal pregnancy in a 39 year old female gravida 4, para 0(+3) is presented. Ultrasonography revealed a viable abdominal pregnancy at 15 weeks gestational age. She was initially managed conservatively. Surgical intervention became necessary at 20 weeks gestational age following Ultrasound detection of foetal demise. The maternal outcome was favourable. This case is presented to highlight the dilemma associated with diagnosis and management of abdominal pregnancy with a review of literature.

  12. Beam characterization at the Neutron Radiography Reactor

    SciTech Connect

    Sarah W. Morgan; Jeffrey C. King; Chad L. Pope

    2013-12-01

    The quality of a neutron-imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam's effective length-to-diameter ratio, neutron flux profile, energy spectrum, potential image quality, and beam divergence, is vital for producing quality radiographic images. This paper provides a characterization of the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam's effective length-to-diameter ratio and potential image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. The NRAD has an effective collimation ratio greater than 125, a beam divergence of 0.3 +_ 0.1 degrees, and a gold foil cadmium ratio of 2.7. The flux profile has been quantified and the facility is an ASTM Category 1 radiographic facility. Based on bare and cadmium covered foil activation results, the neutron energy spectrum used in the current MCNP model of the radiography beamline over-samples the thermal region of the neutron energy spectrum.

  13. Utility of thyroid collars in cephalometric radiography

    PubMed Central

    Sansare, KP; Khanna, V; Karjodkar, F

    2011-01-01

    Objective A study was carried out to investigate the rationale that use of a thyroid collar (TC) in cephalometric radiography hampers the diagnostic and descriptive quality of lateral cephalogram. Methods A randomized observer blinded study was designed. The study consisted of two groups. The first group data were retrieved from the oral radiology archival system having lateral cephalogram without a TC. The second group was selected from the oral radiology department of patients where lateral cephalogram was taken using a TC. Lateral cephalogram was taken on direct digital system, the Kodak 9000 unit (Eastman Kodak, Rochester, NY). 2 observers blinded about the aim of the study were appointed to identify 15 sets of landmarks on the lateral cephalogram. Interobserver variance was also analysed for the study. Results 50 lateral cephalograms in each group were studied. Out of 15 sets of landmarks, 12 were identified consistent with the TC group. Three landmarks, namely the hyoid bone, second cervical vertebra and third cervical vertebra could not be identified on the TC group. There was no significant difference in the interobserver markings on lateral cephalogram. Conclusions TCs do mask a few landmarks on the lateral cephalogram. These landmarks are mainly used for analysis of skeletal maturity index (SMI). Lead TCs are probably the most convenient and easily available means to protect the thyroid from unwanted radiation while taking lateral cephalogram. It is therefore encouraged to use a TC during routine cephalometric radiography where SMI information is not needed. PMID:22065795

  14. A system for fast neutron radiography

    SciTech Connect

    Klann, R.T.

    1997-04-01

    A system has been designed and a neutron generator installed to perform fast neutron radiography. With this system, objects as small as a coin and as large as a 19 liter container have been radiographed. The neutron source is an MF Physics A-711 neutron generator which produces 3 x 10[sup 10] neutrons/second with an average energy of 14. 5 MeV. The radiography system uses x-ray scintillation screens and film in commercially available light-tight cassettes. The cassettes have been modified to include a thin sheet of plastic to produce protons from the neutron beam through elastic scattering from hydrogen and other low Z materials in the plastic. For film densities from 1.8 to 3.0, exposures range from 1.9 x 10[sup 7] n/cm[sup 2] to 3.8 x 10[sup 8] n/cm[sup 2] depending on the type of screen and film. The optimum source-to-film distance was found to be 150 cm. At this distance, the geometric unsharpness was determined to be approximately 2.2-2.3 mm and the smallest hole that could be resolved in a 1.25 cm thick sample had a diameter of 0.079 cm.

  15. Positioning long lines: contrast versus plain radiography

    PubMed Central

    Reece, A; Ubhi, T; Craig, A; Newell, S

    2001-01-01

    AIM—To assess the value of contrast versus plain radiography in determining radio-opaque long line tip position in neonates.
METHODS—In a prospective study, plain radiography was performed after insertion of radio-opaque long lines. If the line tip was not visible on the plain film, a second film with contrast was obtained in an attempt to visualise the tip.
RESULTS—Sixty eight lines were inserted during the study period, 62 of which were included in the study. In 31, a second radiographic examination with contrast was necessary to determine position of the tip. In 29 of these, the line tip was clearly visualised with contrast. On two occasions, the line tip could not be seen because the contrast had filled the vein and obscured the tip from view. Eight of the lines that required a second radiograph with contrast were repositioned.
CONCLUSION—Intravenous contrast should be routinely used in the assessment of long line position in the neonate.

 PMID:11207231

  16. Neutron Radiography Reactor Reactivity -- Focused Lessons Learned

    SciTech Connect

    Eric Woolstenhulme; Randal Damiana; Kenneth Schreck; Ann Marie Phillips; Dana Hewit

    2010-11-01

    As part of the Global Threat Reduction Initiative, the Neutron Radiography Reactor (NRAD) at the Idaho National Laboratory (INL) was converted from using highly enriched uranium (HEU) to low enriched uranium (LEU) fuel. After the conversion, NRAD resumed operations and is meeting operational requirements. Radiography image quality and the number of images that can be produced in a given time frame match pre-conversion capabilities. However, following the conversion, NRAD’s excess reactivity with the LEU fuel was less than it had been with the HEU fuel. Although some differences between model predictions and actual performance are to be expected, the lack of flexibility in NRAD’s safety documentation prevented adjusting the reactivity by adding more fuel, until the safety documentation could be modified. To aid future reactor conversions, a reactivity-focused Lessons Learned meeting was held. This report summarizes the findings of the lessons learned meeting and addresses specific questions posed by DOE regarding NRAD’s conversion and reactivity.

  17. Decompressive laparotomy for abdominal compartment syndrome

    PubMed Central

    Kimball, E.; Malbrain, M.; Nesbitt, I.; Cohen, J.; Kaloiani, V.; Ivatury, R.; Mone, M.; Debergh, D.; Björck, M.

    2016-01-01

    Background The effect of decompressive laparotomy on outcomes in patients with abdominal compartment syndrome has been poorly investigated. The aim of this prospective cohort study was to describe the effect of decompressive laparotomy for abdominal compartment syndrome on organ function and outcomes. Methods This was a prospective cohort study in adult patients who underwent decompressive laparotomy for abdominal compartment syndrome. The primary endpoints were 28‐day and 1‐year all‐cause mortality. Changes in intra‐abdominal pressure (IAP) and organ function, and laparotomy‐related morbidity were secondary endpoints. Results Thirty‐three patients were included in the study (20 men). Twenty‐seven patients were surgical admissions treated for abdominal conditions. The median (i.q.r.) Acute Physiology And Chronic Health Evaluation (APACHE) II score was 26 (20–32). Median IAP was 23 (21–27) mmHg before decompressive laparotomy, decreasing to 12 (9–15), 13 (8–17), 12 (9–15) and 12 (9–14) mmHg after 2, 6, 24 and 72 h. Decompressive laparotomy significantly improved oxygenation and urinary output. Survivors showed improvement in organ function scores, but non‐survivors did not. Fourteen complications related to the procedure developed in eight of the 33 patients. The abdomen could be closed primarily in 18 patients. The overall 28‐day mortality rate was 36 per cent (12 of 33), which increased to 55 per cent (18 patients) at 1 year. Non‐survivors were no different from survivors, except that they tended to be older and on mechanical ventilation. Conclusion Decompressive laparotomy reduced IAP and had an immediate effect on organ function. It should be considered in patients with abdominal compartment syndrome. PMID:26891380

  18. High Brightness Neutron Source for Radiography

    SciTech Connect

    Cremer, J. T.; Piestrup, Melvin, A.; Gary, Charles, K.; Harris, Jack, L. Williams, David, J.; Jones, Glenn, E.; Vainionpaa, J. , H.; Fuller, Michael, J.; Rothbart, George, H.; Kwan, J., W.; Ludewigt, B., A.; Gough, R.., A..; Reijonen, Jani; Leung, Ka-Ngo

    2008-12-08

    This research and development program was designed to improve nondestructive evaluation of large mechanical objects by providing both fast and thermal neutron sources for radiography. Neutron radiography permits inspection inside objects that x-rays cannot penetrate and permits imaging of corrosion and cracks in low-density materials. Discovering of fatigue cracks and corrosion in piping without the necessity of insulation removal is possible. Neutron radiography sources can provide for the nondestructive testing interests of commercial and military aircraft, public utilities and petrochemical organizations. Three neutron prototype neutron generators were designed and fabricated based on original research done at the Lawrence Berkeley National Laboratory (LBNL). The research and development of these generators was successfully continued by LBNL and Adelphi Technology Inc. under this STTR. The original design goals of high neutron yield and generator robustness have been achieved, using new technology developed under this grant. In one prototype generator, the fast neutron yield and brightness was roughly 10 times larger than previously marketed neutron generators using the same deuterium-deuterium reaction. In another generator, we integrate a moderator with a fast neutron source, resulting in a high brightness thermal neutron generator. The moderator acts as both conventional moderator and mechanical and electrical support structure for the generator and effectively mimics a nuclear reactor. In addition to the new prototype generators, an entirely new plasma ion source for neutron production was developed. First developed by LBNL, this source uses a spiral antenna to more efficiently couple the RF radiation into the plasma, reducing the required gas pressure so that the generator head can be completely sealed, permitting the possible use of tritium gas. This also permits the generator to use the deuterium-tritium reaction to produce 14-MeV neutrons with increases

  19. Conventional Versus Digital Radiography in Detecting Root Canal Type in Maxillary Premolars: An in Vitro Study

    PubMed Central

    Moshfeghi, Mahkameh; Sajadi, Soodabeh Sadat; Sajadi, Sepideh; Shahbazian, Majid

    2013-01-01

    Objective: Successful endodontic therapy depends on adequate mechanical and chemical debridement of the canal which requires knowledge of the canal morphology. Conventional radiography has been used to evaluate the canal type; however, direct digital radiography has recently been practiced for this purpose due to the shortcomings of conventional radiography. The aim of the present study was to compare the accuracy of digital and conventional radiography taken at 0° and 30° angles in the diagnosis of the canal type of extracted maxillary premolars. Materials and Methods: This diagnostic study was performed on 90 extracted maxillary premolars. Conventional and digital radiographies were taken of all teeth at 0° and 30° horizontal angles. The images were assessed by an oral and maxillofacial radiologist. The clearing technique was used as the gold standard. The canal type was determined using Weine classification. The agreement between each one of the 4 radiographic modalities and gold standard was determined by kappa statistics. Results: The kappa values for the agreement of parallel conventional, 30° conventional, parallel digital and 30° digital modalities with the clearing technique were 0.059, 0.215, 0.043 and 0.391, respectively. Parallel modalities were unable to determine the tooth canal type. Radiographic images taken at 30° significantly determined the canal type, although only a poor level of agreement was noted between the two modalities and the clearing technique. Conclusion: All modalities had limited value to determine the root canal type in maxillary premolars. However, direct digital imaging taken at 30° angle showed the highest accuracy for canal type assessment. PMID:23724205

  20. K-(alpha) Radiography at 20-100 keV Using Short-Pulse Lasers

    SciTech Connect

    Park, H S; Chambers, D; Clarke, R; Eagleton, R; Giraldez, E; Goldsack, T; Heathcote, R; Izumi, N; Key, M; King, J; Koch, J; Landen, O L; Mackinnon, A; Nikroo, A; Patel, P; Pasley, J; Remington, B; Robey, H; Snavely, R; Steinman, D; Stephenson, R; Stoeckl, C; Storm, M; Tabak, M; Theobald, W; Town, R J

    2005-08-29

    X-ray radiography is an important tool for diagnosing and imaging planar and convergent hydrodynamics phenomena for laser experiments. Until now, hydrodynamics experiments at Omega and NIF utilize E{sub x-ray} < 9 keV backlighter x-rays emitted by thermal plasmas. However, future experiments will need to diagnose larger and denser targets and will require x-ray probes of energies from 20-100 keV and possibly up to 1 MeV. Hard K-{alpha} x-ray photons can be created through high-energy electron interactions in the target material after irradiation by petawatt-class high-intensity-short-pulse lasers with > 10{sup 17} W/cm{sup 2}. We have performed several experiments on the JanUSP, and the Vulcan 100TW, and Vulcan Petawatt lasers to understand K-{alpha} sources and to test radiography concepts. 1-D radiography using an edge-on foil and 2-D radiography using buried wires and cone-fiber targets were tested. We find that 1-D thin edge-on foils can have imaging resolution better than 10 {micro}m. Micro volume targets produce bright sources with measured conversion efficiency from laser energy to x-ray photons of {approx} 1 x 10{sup -5}. This level of conversion may not be enough for 2-D point projection radiography. A comparison of our experimental measurements of small volume sources with the LSP/PIC simulation show similar K-{alpha} creation profiles but discrepancy in absolute yields.

  1. [Inflammatory abdominal aortic aneurysm].

    PubMed

    Siebenmann, R; Schneider, K; von Segesser, L; Turina, M

    1988-06-11

    348 cases of abdominal aortic aneurysm were reviewed for typical features of inflammatory aneurysm (IAAA) (marked thickening of aneurysm wall, retroperitoneal fibrosis and rigid adherence of adjacent structures). IAAA was present in 15 cases (14 male, 1 female). When compared with patients who had ordinary aneurysms, significantly more patients complained of back or abdominal pain (p less than 0.01). Erythrocyte sedimentation rate was highly elevated. Diagnosis was established in 7 of 10 computed tomographies. 2 patients underwent emergency repair for ruptured aneurysm. Unilateral ureteral obstruction was present in 4 cases and bilateral in 1. Repair of IAAA was performed by a modified technique. Histological examination revealed thickening of the aortic wall, mainly of the adventitial layer, infiltrated by plasma cells and lymphocytes. One 71-year-old patient operated on for rupture of IAAA died early, and another 78-year-old patient after 5 1/2 months. Control computed tomographies revealed spontaneous regression of inflammatory infiltration after repair. Equally, hydronephrosis due to ureteral obstruction could be shown to disappear or at least to decrease. IAAA can be diagnosed by computed tomography with high sensitivity. Repair involves low risk, but modification of technique is necessary. The etiology of IAAA remains unclear.

  2. Fertility after abdominal myomectomy.

    PubMed

    Connolly, G; Doyle, M; Barrett, T; Byrne, P; De Mello, M; Harrison, R F

    2000-07-01

    This study aimed to evaluate the morbidity and pregnancy outcome of myomectomy in infertile women with uterine fibroids. This was a cross-sectional study. Records were reviewed for 100 consecutive women in the Rotunda Hospital who underwent myomectomy in the years 1995-1996. A questionnaire regarding subsequent fertility was sent. The study was carried out in the infertility unit at the Rotunda Hospital, Dublin, Ireland. Seventy-five women responded. Multiple myomectomy was performed in 52 (70%). Mean fibroid size was 6.8 cm (range 2-14.5 cm). Nine women (12%) developed complications; five had menstrual problems, two had wound discomfort and two had abdominal discomfort. Twenty-five women (33%) became pregnant. Seven (28%) were IVF pregnancies. Overall six (24%) miscarried. In 19 of 25, pregnancy occurred where fibroids were the only identifiable cause of infertility. We conclude that abdominal myomectomy is associated with a favourable outcome in infertile women particularly if no other confounding variable is present.

  3. Plain radiography, renography, and 99mTc-DMSA renal scintigraphy before and after extracorporeal shock wave lithotripsy for urolithiasis.

    PubMed

    Munck, O; Gerquari, I; Møller, J T; Jensen, L I; Thomsen, H S

    1992-11-01

    Eighteen patients were evaluated before and 5 weeks after the first treatment with extracorporeal shock wave lithotripsy (ESWL) using abdominal plain radiography, 131I-hippuran probe renography, and 99mTc-dimercaptosuccinic acid scintigraphy. In 6 patients no urolithiasis was present on the post ESWL plain radiograph, in 7 the size had decreased, and in 5 the stone mass was unchanged. The renograms were within normal range in the 6 patients who were cured by ESWL, whereas this was the case for only 4 of the 12 who still had renal calculi. In 2 patients pelvic stones had descended into the ureter after ESWL, and the renograms indicated obstruction. Another 3 patients had ureteral stones, whereas in the remaining 7 patients only pelvic stones were found on the plain radiographs. In no patient did the scintigrams reveal scars. It is concluded that abdominal plain radiography of the urinary tract and probe renography are complementary and sufficient in the monitoring of patients with urolithiasis post ESWL.

  4. [Abdominal approaches and drainages of the abdominal cavity].

    PubMed

    Hagel, C; Schilling, M

    2006-04-01

    Appropriate access to the abdominal cavity is the first and crucial step for successful abdominal surgical intervention. In planning the incision, several variables have to be considered, such as anatomy of the abdominal wall, localization of the target organ, and individual conditions (previous incisions, minimal access surgery, etc). Medial laparotomy is the preferred incision for emergency cases and ill-defined pathologies, allowing access and hence exploration to all quadrants. Transverse laparotomies give superior access to the dorsal and right aspects of the liver and cause less pain in patients unfit for regional anesthetic procedures. Draining of the abdominal cavity is used after various resective and reconstructive procedures, but there is little evidence for its use in a number of operations such as gastric, hepatic, and colorectal resections. Advantages and disadvantages of different abdominal wall incisions and drainages are discussed.

  5. How I Manage Abdominal Injuries.

    ERIC Educational Resources Information Center

    Haycock, Christine E.

    1986-01-01

    In sports, abdominal injuries occur most frequently in cycling, horseback riding, and skiing. Most involve children, not adults. Any athlete sustaining a severe blow to the abdomen should be examined. Guidelines are provided for recognizing and treating injuries to the abdominal muscles, kidneys, spleen, and liver. (Author/MT)

  6. CT of abdominal tuberculosis

    SciTech Connect

    Epstein, B.M.; Mann, J.H.

    1982-11-01

    Intraabdominal tuberculosis (TB) presents with a wide variety of clinical and radiologic features. Besides the reported computed tomographic (CT) finding of high-density ascites in tuberculous peritonitis, this report describes additional CT features highly suggestive of abdominal tuberculosis in eight cases: (1) irregular soft-tissue densities in the omental area; (2) low-density masses surrounded by thick solid rims; (3) a disorganized appearance of soft-tissue densities, fluid, and bowel loops forming a poorly defined mass; (4) low-density lymph nodes with a multilocular appearance after intravenous contrast administration; and (5) possibly high-density ascites. The differential diagnosis of these features include lymphoma, various forms of peritonitis, peritoneal carcinomatosis, and peritoneal mesothelioma. It is important that the CT features of intraabdominal tuberculosis be recognized in order that laparotomy be avoided and less invasive procedures (e.g., laparoscopy, biopsy, or a trial of antituberculous therapy) be instituted.

  7. Digital mammography performed with computed radiography technology.

    PubMed

    Jouan, B

    1999-07-01

    Introduced by Fuji Photo Film Japan in the early 1980s, computed radiography (CR) technology has developed considerably since then to become the mature widely installed technology it is today (about 7500 systems worldwide). Various mammographic examinations require high performance results to which CR complies on demand or following some procedures such as geometrical magnification carried out during the examination. The basic CR principles and digital image processing as well as technical improvements are detailed in this study, which also includes a synthesis of the articles on CR mammographic applications referenced in the bibliography, focusing on strong points, limits and current methods of surpassing these limits. New CR technology development perspectives in mammography and computed assisted diagnosis (CAD) algorithms will allow wider use of this method in the near future.

  8. Measuring microfocus focal spots using digital radiography

    SciTech Connect

    Fry, David A

    2009-01-01

    Measurement of microfocus spot size can be important for several reasons: (1) Quality assurance during manufacture of microfocus tubes; (2) Tracking performance and stability of microfocus tubes; (3) Determining magnification (especially important for digital radiography where the native spatial resolution of the digital system is not adequate for the application); (4) Knowledge of unsharpness from the focal spot alone. The European Standard EN 12543-5 is based on a simple geometrical method of calculating focal spot size from unsharpness of high magnification film radiographs. When determining microfocus focal spot dimensions using unsharpness measurements both signal-to-noise (SNR) and magnification can be important. There is a maximum accuracy that is a function of SNR and therefore an optimal magnification. Greater than optimal magnification can be used but it will not increase accuracy.

  9. Digital radiography exposure indices: A review

    SciTech Connect

    Mothiram, Ursula; Brennan, Patrick C; Lewis, Sarah J; Moran, Bernadette; Robinson, John

    2014-06-15

    Digital radiography (DR) technologies have the advantage of a wide dynamic range compared to their film-screen predecessors, however, this poses a potential for increased patient exposure if left unchecked. Manufacturers have developed the exposure index (EI) to counter this, which provides radiographers with feedback on the exposure reaching the detector. As these EIs were manufacturer-specific, a wide variety of EIs existed. To offset this, the international standardised EI has been developed by the International Electrotechnical Commission (IEC) and the American Association of Physicists in Medicine (AAPM). The purpose of this article is to explore the current literature relating to EIs, beginning with the historical development of the EI, the development of the standardised EI and an exploration of common themes and studies as evidenced in the research literature. It is anticipated that this review will provide radiographers with a useful guide to understanding EIs, their application in clinical practice, limitations and suggestions for further research.

  10. Muscle parameters estimation based on biplanar radiography.

    PubMed

    Dubois, G; Rouch, P; Bonneau, D; Gennisson, J L; Skalli, W

    2016-11-01

    The evaluation of muscle and joint forces in vivo is still a challenge. Musculo-Skeletal (musculo-skeletal) models are used to compute forces based on movement analysis. Most of them are built from a scaled-generic model based on cadaver measurements, which provides a low level of personalization, or from Magnetic Resonance Images, which provide a personalized model in lying position. This study proposed an original two steps method to access a subject-specific musculo-skeletal model in 30 min, which is based solely on biplanar X-Rays. First, the subject-specific 3D geometry of bones and skin envelopes were reconstructed from biplanar X-Rays radiography. Then, 2200 corresponding control points were identified between a reference model and the subject-specific X-Rays model. Finally, the shape of 21 lower limb muscles was estimated using a non-linear transformation between the control points in order to fit the muscle shape of the reference model to the X-Rays model. Twelfth musculo-skeletal models were reconstructed and compared to their reference. The muscle volume was not accurately estimated with a standard deviation (SD) ranging from 10 to 68%. However, this method provided an accurate estimation the muscle line of action with a SD of the length difference lower than 2% and a positioning error lower than 20 mm. The moment arm was also well estimated with SD lower than 15% for most muscle, which was significantly better than scaled-generic model for most muscle. This method open the way to a quick modeling method for gait analysis based on biplanar radiography.

  11. Simple solution to the Fresnel-Kirchoff diffraction integral for application to refraction-enhanced radiography.

    PubMed

    Koch, J A; Landen, O L; Suter, L J; Masse, L P

    2013-07-01

    We present a simple solution to the Fresnel-Kirchoff diffraction integral that is appropriate for x-ray radiography of strongly absorbing and phase-shifting objects in the geometrical optics regime, where phase contrast enhancements can be considered to be caused by refraction by a semi-opaque object. We demonstrate its accuracy by comparison to brute-force numerical ray trace and diffraction calculations of a representative simulated object, and show excellent agreement for spatial scales corresponding to Fresnel numbers greater than unity. The result represents a significant improvement over approximate formulas typically used in analysis of refraction-enhanced radiographs, particularly for radiography of transient phenomena in objects that strongly refract and show significant absorption.

  12. Feasibility of using neutron radiography to inspect the Space Shuttle solid rocket booster aft skirt, forward skirt and frustum. Part 1: Summary report

    NASA Technical Reports Server (NTRS)

    Barton, J. P.; Bader, J. W.; Brenizer, J. S.; Hosticka, B.

    1992-01-01

    The space shuttle's solid rocket boosters (SRB) include components made primarily of aluminum that are parachuted back for retrieval from the ocean and refurbished for repeated usage. Nondestructive inspection methods used on these aging parts to reduce the risk of unforeseen problems include x-ray, ultrasonics, and eddy current. Neutron radiography tests on segments of an SRB component show that entrapped moisture and naturally occurring aluminum corrosion can be revealed by neutron radiography even if present in only small amounts. Voids in sealant can also be evaluated. Three alternatives are suggested to follow-up this study: (1) take an SRB component to an existing neutron radiography system; (2) take an existing mobile neutron radiography system to the NASA site; or (3) plan a dedicated system custom designed for NASA applications.

  13. The Enhanced Workflow and Efficiency of the Wireless Local Area Network (WLAN)-Based Direct Digital Radiography (DDR) Portable Radiography.

    PubMed

    Ngan, Tsz-Lung; Wong, Edward Ting-Hei; Ng, Kris Lap-Shun; Jeor, Patrick Kwok-Shing; Lo, Gladys Goh

    2015-06-01

    With the implementation of the PACS in the hospital, there is an increasing demand from the clinicians for immediate access and display of radiological images. Recently, our hospital has installed the first wireless local area network (WLAN)-based direct digital radiography (DDR) portable radiography system. The DDR portable radiography system allows wireless retrieval of modality worklist and wireless transmission of portable X-ray image on the console to the Picture Archiving and Communication System (PACS), via WLAN connection of wireless fidelity (Wi-Fi). The aim of this study was to analyze the workflow and performance between the WLAN-based DDR portable radiography system and the old practice using conventional portable X-ray machine with computed radiography (CR) system. A total of 190 portable chest X-ray examinations were evaluated and timed, using the conventional portable X-ray machine with CR from March to April of 2012 and using the new DDR portable radiography system on December of 2012 (n = 97 for old system and n = 93 for DDR portable system). The time interval of image becoming available to the PACS using the WLAN-based DDR portable radiography system was significantly shorter than that of the old practice using the conventional portable X-ray machine with CR (6.8 ± 2.6 min for DDR portable system; 23 ± 10.2 min for old system; p < 0.0001), with the efficiency improved by 70 %. The implementation of the WLAN-based DDR portable radiography system can enhance the workflow of portable radiography by reduction of procedural steps.

  14. CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: results of an international multicenter trial.

    PubMed

    Rühl, Ricarda; Wozniak, Magdalena M; Werk, Michael; Laurent, François; Mager, Georg; Montaudon, Michel; Pattermann, Andreas; Scherrer, Antoine; Tasu, Jean-Pierre; Pech, Maciej; Ricke, Jens

    2008-09-01

    To assess both sensitivity and specificity of digital chest radiography alone and in conjunction with dual-exposure dual-energy chest radiography for the detection and classification of pulmonary nodules. One hundred patients with a total of 149 lung nodules (3-45 mm; median, 11 mm) confirmed by CT were included in this study. Dual-exposure dual-energy chest radiographies of each patient were obtained using a CsI detector system. Experienced board-certified chest radiologists from four different medical centers in Europe reviewed standard chest radiographs alone and in conjunction with dual-energy images blinded and in random order. The reviewers rated the probability of presence, calcification and malignancy of all lung nodules on a five-point rating scale. Lesions detected were identified by applying a specific coordinate system to enable precise verification by the study leader. A receiver-operating characteristic (ROC) analysis was performed. In addition to the 149 true-positive CT proven lesions, 236 false-positive lung nodules were described in digital chest radiographies in conjunction with dual-energy chest radiographies. The cumulative sensitivity of chest radiography in conjunction with dual energy was 43%, specificity was 55%. For digital radiography alone, sensitivity was 35% and specifity was 83%. For the dual energy system, positive predictive value was 58%, and negative predictive value was 66% compared to the digital radiography with a positive predictive value of 59% and a negative predictive value of 65%. Areas under the curve in a ROC analysis resulted in 0.631 (95% confidence interval =0.61 to 0.65) for radiography with dual energy and 0.602 (95% confidence interval =0.58 to 0.63) for digital radiography alone. This difference was not statistically significant. For the detection of lesion calcification or the determination of malignancy, ROC analysis also failed to show significant differences. CsI-based flat-panel dual-exposure dual

  15. Archaeometric studies by neutron, x-ray radiography and microCT

    NASA Astrophysics Data System (ADS)

    Latini, R. M.; Bellido, A. V. B.; Vinagre Filho, U. M.; Souza, M. I. S.; Lima, I.; Oliveira, D. F.; Lopes, R. T.

    2013-05-01

    The aim of this study is to investigate manufacturing techniques used in prehistoric Brazilian pottery from Acre state and Araruama, Rio de Janeiro state, Brazil, using Neutron and X-Ray Radiography. For the neutrongraphy different fragments of pottery were submitted to a neutron flux of the order of 105n.cm-2.s-1 for 3 minutes at the Argonauta research reactor of the Instituto de Engenharia Nuclear (IEN)/CNEN. Digital processing techniques using imaging plate were applied to process the image of the selected sample. For the radiography the sample were exposed to an X-Rays in the Feinfocus Model FX100 and the image was obtained by Flat Panel GE IT Model DXR 250V at the Laboratório de Instrumentação Nuclear (LIN) - COPPE/UFRJ. The Neutrongraphy and radiography shows two different manufacturing details: palette and rollers and the microtomography shows cavities in the clay body and different temper applied in the pottery production. The preliminary results shows promising techniques applied for the pottery manufacturing information and as complement for better understanding the ceramics classification and precedence.

  16. Economics of abdominal wall reconstruction.

    PubMed

    Bower, Curtis; Roth, J Scott

    2013-10-01

    The economic aspects of abdominal wall reconstruction are frequently overlooked, although understandings of the financial implications are essential in providing cost-efficient health care. Ventral hernia repairs are frequently performed surgical procedures with significant economic ramifications for employers, insurers, providers, and patients because of the volume of procedures, complication rates, the significant rate of recurrence, and escalating costs. Because biological mesh materials add significant expense to the costs of treating complex abdominal wall hernias, the role of such costly materials needs to be better defined to ensure the most cost-efficient and effective treatments for ventral abdominal wall hernias.

  17. A bizarre abdominal cystic lesion.

    PubMed

    Zucchini, Giorgia; Pezzilli, Raffaele; Ricci, Claudio; Casadei, Riccardo; Santini, Donatella; Calculli, Lucia; Corinaldesi, Roberto

    2010-09-06

    In spite of careful intraoperative precautions and gauze counts, mistakes can still occur during surgery. In the case reported, a retained gauze leaved during a surgical approach for removing a solid-cystic papillary tumor localized in the pancreatic tail, caused both persistent abdominal discomfort and the presence of an abdominal cystic lesion at imaging techniques. When a previous operative history is present, a foreign body should be taken into account in the differential diagnosis of a patient with an intra-abdominal cystic mass. Finally, radio-opaque marker should be routinely used by surgeons in order to reach a correct diagnosis in operated patients having retained gauze.

  18. Acute incarcerated external abdominal hernia

    PubMed Central

    Yang, Xue-Fei

    2014-01-01

    External abdominal hernia occurs when abdominal organs or tissues leave their normal anatomic site and protrude outside the skin through the congenital or acquired weakness, defects or holes on the abdominal wall, including inguinal hernia, umbilical hernia, femoral hernia and so on. Acute incarcerated hernia is a common surgical emergency. With advances in minimally invasive devices and techniques, the diagnosis and treatment have witnessed major changes, such as the use of laparoscopic surgery in some cases to achieve minimally invasive treatment. However, strict adherence to the indications and contraindications is still required. PMID:25489584

  19. Radiography with the Fission Neutrons from Californium-252

    DTIC Science & Technology

    1977-07-01

    iftD-Ao45 3^ m-77-B1i2i TECHNICAL 7󈧖 LIBRARY lADfto^^^ RADIOGRAPHY WITH THE FISSION NEUTRONS FROM CALIFORNIUM -252 JOHN J. ANTAL and...TITLE C«id Sub(l(/«J RADIOGRAPHY WITH THE FISSION NEUTRONS FROM CALIFORNIUM -252 5. TYPE OF REPORT it PERIOD COVERED Final Report 6...Cellulose nitrate Californium -252 20. ABSTRACT (Continue on reverse aide 11 necessary and identity by block number) (SEE REVERSE SIDE) DD 1

  20. A Review of Full-Body Radiography in Nontraumatic Emergency Medicine

    PubMed Central

    Whiley, S. P.; Mantokoudis, G.; Ott, D.; Zimmerman, H.; Exadaktylos, A. K.

    2012-01-01

    This paper reports on the application of full-body radiography to nontraumatic emergency situations. The Lodox Statscan is an X-ray machine capable of imaging the entire body in 13 seconds using linear slit scanning radiography (LSSR). Nontraumatic emergency applications in ventriculoperitoneal (VP) shunt visualisation, emergency room arteriography (ERA), detection of foreign bodies, and paediatric emergency imaging are presented. Reports show that the fast, full-body, and low-dose scanning capabilities of the Lodox system make it well suited to these applications, with the same or better image quality, faster processing times, and lower dose to patients. In particular, the large format scans allowing visualisation of a greater area of anatomy make it well suited to VP shunt monitoring, ERA, and the detection of foreign bodies. Whilst more studies are required, it can be concluded that the Lodox Statscan has the potential for widespread use in these and other nontraumatic emergency radiology applications. PMID:23243508

  1. Inspection of the hydrogen gas pressure with metal shield by cold neutron radiography at CMRR

    NASA Astrophysics Data System (ADS)

    Li, Hang; Cao, Chao; Huo, Heyong; Wang, Sheng; Wu, Yang; Yin, Wei; Sun, Yong; Liu, Bin; Tang, Bin

    2017-04-01

    The inspection of the process of gas pressure change is important for some applications (e.g. gas tank stockpile or two phase fluid model) which need quantitative and non-touchable measurement. Neutron radiography provides a suitable tool for such investigations with nice resolution. The quantitative cold neutron radiography (CNR) is developed at China Mianyang Research Reactor (CMRR) to measure the hydrogen gas pressure with metal shield. Because of the high sensitivity to hydrogen, even small change of the hydrogen pressure can be inspected by CNR. The dark background and scattering neutron effect are both corrected to promote measurement precision. The results show that CNR can measure the hydrogen gas pressure exactly and the pressure value average relative error between CNR and barometer is almost 1.9%.

  2. Validation of a computed radiography device to monitor the HIV-1 RNase H activity

    NASA Astrophysics Data System (ADS)

    Esposito, F.; Fanti, V.; Marzeddu, R.; Randaccio, P.; Tramontano, E.; Zinzula, L.

    2009-08-01

    A commercially available computed radiography (CR) system for dental radiography was used to produce images from radiolabeled polyacrilamide gel electrophoresis (PAGE) assays. Typically, similar investigations require specific and expensive autoradiography devices. The CR unit was characterized in terms of sensitivity and fading by means of a 90Sr source that well simulates the experimental conditions, and then used for quantitative analyses of the human immunodeficiency virus type 1 (HIV-1) reverse transcriptase (RT) polymerase-independent ribonuclease H (RNase H) activity monitored by PAGE analysis. The results showed that the present methodology allows quantifying effectively the RNase H catalyses and that the obtained data are in good agreement with previous reference works. Finally, in order to further validate the present method in terms of relationship between enzyme activity, the rate of products formation and signal intensity, a PAGE analyses of the HIV-1 RNase H inhibition by the known diketo acid derivative RDS1643 was carried out.

  3. Location of mental foramen using digital panoramic Radiography

    PubMed Central

    Mohamed, Ajmal; Nataraj, Kannan; Mathew, Vinod B.; Varma, Beena; Mohamed, Shamil; Valappila, Nidhin J.; Meena, Aravind S.

    2016-01-01

    Objective: Comparative evaluation of the location of mental foramen in different age groups. Determine the variation in position of mental foramen with gender using digital panoramic radiography. Materials and Methods: Digital panoramic radiographs of 250 patients were reviewed. The study population was divided into five age groups with 50 patients each. Radiographic position of mental foramen was evaluated in each radiograph based on three parameters. Measurements were taken in each radiograph using Planmeca Dimaxis pro version 4.4.0 (Helsinki, Finland). The collected data were subjected to statistical analysis using paired Student's t-test. Results: The mean distance of position of mental foramen showed a significant variation within the five age groups. In the first group, female patients showed an increase in mean distance of mental foramen position in relation to three parameters. From the second to fifth groups, male patient showed an increase in the mean distance of mental foramen position. The first and fifth group showed a reduced mean distance of mental foramen position when compared to other age groups. Conclusion: This study concluded that the position of mental foramen varies with age. There was a gender-related variation in position of mental foramen within the population too. PMID:27555723

  4. [Penetrating abdominal injuries].

    PubMed

    Nesbakken, A; Pillgram-Larsen, J; Naess, F; Gerner, T; Solheim, K; Stadaas, J O; Gjøra, O

    1990-02-28

    We have reviewed the medical records of 111 patients treated for abdominal stab wounds during the period 1980-87. Our two hospitals serve a catchment area of about 450,000 people. Exploratory laparotomy was performed in 89 patients with suspected peritoneal penetration. In 16 patients the laparotomy was negative, and in 15 patients only minor injuries were noted. There were no serious complications in these 31 patients. Twenty-seven patients had thoracic wounds below the fourth intercostal space, 15 with intraabdominal injuries. The most common injuries were lacerations of the liver, the small bowel and the diaphragm. The mortality in the series was 2%. Stab wounds are infrequent in Norway, and most surgeons have limited experience of such injuries. We discuss whether to employ immediate exploratory laparotomy or selective management when the peritoneum has been penetrated. When there is no evidence of evisceration or omental protrusion, local exploration of the wound should be performed in order to confirm or exclude peritoneal penetration. Injury to the diaphragm and intraabdominal viscera should always be suspected in thoracic stab wounds below the fourth intercostal space.

  5. Abdominal aortic feminism.

    PubMed

    Mortimer, Alice Emily

    2014-11-14

    A 79-year-old woman presented to a private medical practice 2 years previously for an elective ultrasound screening scan. This imaging provided the evidence for a diagnosis of an abdominal aortic aneurysm (AAA) to be made. Despite having a number of recognised risk factors for an AAA, her general practitioner at the time did not follow the guidance set out by the private medical professional, that is, to refer the patient to a vascular specialist to be entered into a surveillance programme and surgically evaluated. The patient became symptomatic with her AAA, was admitted to hospital and found to have a tender, symptomatic, 6 cm leaking AAA. She consented for an emergency open AAA repair within a few hours of being admitted to hospital, despite the 50% perioperative mortality risk. The patient spent 4 days in intensive care where she recovered well. She was discharged after a 12 day hospital stay but unfortunately passed away shortly after her discharge from a previously undiagnosed gastric cancer.

  6. Improvement of material decomposition and image quality in dual-energy radiography by reducing image noise

    NASA Astrophysics Data System (ADS)

    Lee, D.; Kim, Y.-s.; Choi, S.; Lee, H.; Choi, S.; Jo, B. D.; Jeon, P.-H.; Kim, H.; Kim, D.; Kim, H.; Kim, H.-J.

    2016-08-01

    Although digital radiography has been widely used for screening human anatomical structures in clinical situations, it has several limitations due to anatomical overlapping. To resolve this problem, dual-energy imaging techniques, which provide a method for decomposing overlying anatomical structures, have been suggested as alternative imaging techniques. Previous studies have reported several dual-energy techniques, each resulting in different image qualities. In this study, we compared three dual-energy techniques: simple log subtraction (SLS), simple smoothing of a high-energy image (SSH), and anti-correlated noise reduction (ACNR) with respect to material thickness quantification and image quality. To evaluate dual-energy radiography, we conducted Monte Carlo simulation and experimental phantom studies. The Geant 4 Application for Tomographic Emission (GATE) v 6.0 and tungsten anode spectral model using interpolation polynomials (TASMIP) codes were used for simulation studies and digital radiography, and human chest phantoms were used for experimental studies. The results of the simulation study showed improved image contrast-to-noise ratio (CNR) and coefficient of variation (COV) values and bone thickness estimation accuracy by applying the ACNR and SSH methods. Furthermore, the chest phantom images showed better image quality with the SSH and ACNR methods compared to the SLS method. In particular, the bone texture characteristics were well-described by applying the SSH and ACNR methods. In conclusion, the SSH and ACNR methods improved the accuracy of material quantification and image quality in dual-energy radiography compared to SLS. Our results can contribute to better diagnostic capabilities of dual-energy images and accurate material quantification in various clinical situations.

  7. Neutron radiography inspection of investment castings.

    PubMed

    Richards, W J; Barrett, J R; Springgate, M E; Shields, K C

    2004-10-01

    Investment casting, also known as the lost wax process, is a manufacturing method employed to produce near net shape metal articles. Traditionally, investment casting has been used to produce structural titanium castings for aero-engine applications with wall thickness less than 1 in (2.54 cm). Recently, airframe manufacturers have been exploring the use of titanium investment casting to replace components traditionally produced from forgings. Use of titanium investment castings for these applications reduces weight, cost, lead time, and part count. Recently, the investment casting process has been selected to produce fracture critical structural titanium airframe components. These airframe components have pushed the traditional inspection techniques to their physical limits due to cross sections on the order of 3 in (7.6 cm). To overcome these inspection limitations, a process incorporating neutron radiography (n-ray) has been developed. In this process, the facecoat of the investment casting mold material contains a cocalcined mixture of yttrium oxide and gadolinium oxide. The presence of the gadolinium oxide, allows for neutron radiographic imaging (and eventual removal and repair) of mold facecoat inclusions that remain within these thick cross sectional castings. Probability of detection (POD) studies have shown a 3 x improvement of detecting a 0.050 x 0.007 in2 (1.270 x 0.178 mm2) inclusion of this cocalcined material using n-ray techniques when compared to the POD using traditional X-ray techniques. Further, it has been shown that this n-ray compatible mold facecoat material produces titanium castings of equal metallurgical quality when compared to the traditional materials. Since investment castings can be very large and heavy, the neutron radiography facilities at the University of California, Davis McClellan Nuclear Radiation Center (UCD/MNRC) were used to develop the inspection techniques. The UCD/MNRC has very unique facilities that can handle large

  8. Screening for Abdominal Aortic Aneurysm

    MedlinePlus

    ... signs or symptoms of an abdominal aortic aneurysm (AAA). The final recommendation statement summarizes what the Task ... the potential benefits and harms of screening for AAA: (1) Men ages 65 to 75 who smoke ...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    MedlinePlus Videos and Cool Tools

    ... not use ionizing radiation, has no known harmful effects, and is particularly valuable for evaluating abdominal, pelvic ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ...

  10. Incentive spirometry after abdominal surgery.

    PubMed

    Davis, Suja P

    Patients face various possible complications after abdominal surgery. This article examines best practice in guiding and teaching them how to use an incentive spirometer to facilitate recovery and prevent respiratory complications.

  11. Abdominal scar characteristics as a predictor of cervical stenosis after abdominal radical trachelectomy

    PubMed Central

    Li, Xiaoqi; Li, Jin; Ju, Xingzhu; Chen, Xiaojun; Wu, Xiaohua

    2016-01-01

    To investigate whether abdominal scar characteristics could predict the occurrence of cervical stenosis after abdominal radical trachelectomy (ART), we conducted a retrospective study and investigated the relationship between abdominal scar characteristics and the occurrence of cervical stenosis in patients one year after undergoing ART. The abdominal scars were evaluated using the Vancouver Scar Scale (VSS). Seventy-two participants were enrolled in the study, including 15 (20.8%) women with cervical stenosis, and 57 (79.2%) without stenosis. Results showed that the mean abdominal scar score assessed by VSS was higher in patients with cervical stenosis (7, range: 1–10) compared to those without stenosis (4, range: 0–9) (P = 0.001). Incidence rates of cervical stenosis increased with the VSS score. For women with VSS scores of 0 to 4, 5, 6, 7, 8, 9 and 10, respectively, the occurrences of cervical stenosis were 6.1%, 16.7%, 16.7%, 27.3%, 37.5%, 50% and 100%. The cutoff point of VSS score was 7 according to the receiver operating characteristic (ROC) curve. Fourteen of the 15 stenosis happened either in patients without anti-stenosis tools (Foley catheters or tailed intrauterine devices) placed during the surgery or after the devices were removed. Our results demonstrated that VSS is an effective approach to assess the presence of cervical stenosis after ART. Women who have an abdominal scar with a VSS score > 7 have a high risk of developing isthmic stenosis without anti-stenosis tools in place. PMID:27191256

  12. Abdominal Complications after Severe Burns

    DTIC Science & Technology

    2009-05-01

    abdominal compartment syndrome, schemic bowel, biliary disease, peptic ulcer disease and astritis requiring laparotomy, small bowel obstruction, rimary fungal...complications in- luded trauma exploratory laparotomy, abdominal com- artment syndrome, ischemic bowel, biliary disease, peptic lcer disease and gastritis, large...70%); 13 for other compli- ations, such as biliary or perineal conditions (26%); and 4 or feeding access (8%). For the civilians, 2 had trauma

  13. Common abdominal emergencies in children.

    PubMed

    D'Agostino, James

    2002-02-01

    Because young children often present to EDs with abdominal complaints, emergency physicians must have a high index of suspicion for the common abdominal emergencies that have serious sequelae. At the same time, they must realize that less serious causes of abdominal symptoms (e.g., constipation or gastroenteritis) are also seen. A gentle yet thorough and complete history and physical examination are the most important diagnostic tools for the emergency physician. Repeated examinations and observation are useful tools. Physicians should listen carefully to parents and their children, respect their concerns, and honor their complaints. Ancillary tests are inconsistent in their value in assessing these complaints. Abdominal radiographs can be normal in children with intussusception and even malrotation and early volvulus. Unlike the classic symptoms seen in adults, young children can display only lethargy or poor feeding in cases of appendicitis or can appear happy and playful between paroxysmal bouts of intussusception. The emergency physician therefore, must maintain a high index of suspicion for serious pathology in pediatric patients with abdominal complaints. Eventually, all significant abdominal emergencies reveal their true nature, and if one can be patient with the child and repeat the examinations when the child is quiet, one will be rewarded with the correct diagnosis.

  14. Neutron Computed Tomography Using Real-Time Neutron Radiography.

    NASA Astrophysics Data System (ADS)

    Sulcoski, Mark Francis

    Conventional neutron radiography of an object records a two-dimensional distribution of the neutron beam intensity after it has passed through an object. The neutron radiograph, whether static film or real-time, may be considered a "shadow graph" of the object. In a shadow graph, internal structures in an object may mask one another making it difficult or impossible to precisely define the internals of the object. This problem can be solved by tomographic imaging. A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 (+OR-) 0.2) x 10('11) n/(m('2)-sec)), gold cadmium ratio (52 (+OR-) 3) and effective neutron temperature (83(DEGREES)C (+OR -) 8(DEGREES)C). The angular divergence or nonparallelism of the neutron beam was measured to be \\2.3(DEGREES) (+OR -) 0.1(DEGREES) thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were programmed on an Intellect 100 Image Processing System. The SIRT algorithm was found to be too large and slow on the Intellect 100 to produce useful tomographs. The convolution method produced results near the theoretical resolution limits for a given number of projections. A tomographic resolution of at least 1.3 mm was demonstrated using 200 projections. Computer running time for the convolution method was found to be (TURN)30 seconds for each projection used. A series of experiments were conducted using the convolution method investigating the effect of high and low pass

  15. Visceral scalloping on abdominal computed tomography due to abdominal tuberculosis

    PubMed Central

    Sharma, Vishal; Bhatia, Anmol; Malik, Sarthak; Singh, Navjeet; Rana, Surinder S.

    2017-01-01

    Objective: Scalloping of visceral organs is described in pseudomyxoma peritonei, malignant ascites, among other conditions, but not tuberculosis. Methods: We report findings from a retrospective study of patients with abdominal tuberculosis who had visceral scalloping on abdominal computed tomography (CT). Diagnosis of abdominal tuberculosis was made on the basis of combination of clinical, biochemical, radiological and microbiological criteria. The clinical data, hematological and biochemical parameters, and findings of chest X-ray, CT, Mantoux test, and HIV serology were recorded. Results: Of 72 patients with abdominal tuberculosis whose CT scans were included, seven patients had visceral scalloping. The mean age of these patients was 32.14 ± 8.43 years and four were men. While six patients had scalloping of liver, one had splenic scalloping. The patients presented with abdominal pain (all), abdominal distension (five patients), loss of weight or appetite (all), and fever (four patients). Mantoux test was positive in five, while none had HIV infection. The diagnosis was based on fluid (ascitic or collections) evaluation in four patients, ileo-cecal biopsy in one patient, fine needle aspiration from omental thickening in one patient, and sputum positivity for acid fast bacilli (AFB) in one patient. On CT examination, four patients had ascites, five had collections, one had lymphadenopathy, four had peritoneal involvement, three had pleural effusion, and two had ileo-cecal thickening. All except one patient received standard ATT for 6 months or 9 months (one patient). Pigtail drainage for collections was needed for two patients. Discussion: This report is the first description of visceral scalloping of liver and spleen in patients with abdominal tuberculosis. Previously, this finding has been reported primarily with pseudomyxoma peritonei and peritoneal carcinomatosis. Conclusion: Visceral scalloping may not conclusively distinguish peritoneal

  16. Comparison of state dental radiography safety regulations.

    PubMed

    McDaniel, Thomas F; Parashar, Vijay

    2015-01-01

    The aim of this study was to compare and provide an overview of state policies on occupational exposure, dosimetry, collimation, patient protection, and the use of portable handheld X-ray machines in dentistry. State government webpages containing radiation protection rules and regulations were scanned. The contents were compared against current federal regulations established by the Nuclear Regulatory Commission (NRC) and the US Food and Drug Administration (FDA). They were further evaluated in light of current recommendations from the National Council on Radiation Protection & Measurements (NCRP) and the American Dental Association (ADA). Most states' regulations mirror the exposure limits set forth by the NRC and FDA. Nonregulatory recommendations regarding use of dental radiography are periodically put forth by the NCRP and the ADA. State and federal agencies often follow recommendations from these scientific organizations when creating regulations. Clinicians must be aware of their state's radiation protection rules, as variations among states exist. In addition, recommendations published by organizations such as the NCRP and the ADA, while not legally binding, contribute significantly to the reduction of radiation risks for operators and patients alike.

  17. Patient information extraction in digitized radiography.

    PubMed

    Wu, Hsien-Huang P

    2002-03-01

    Digital imagery is gradually replacing the traditional radiograph with the development of digital radiography and film scanner. This report presents a new method to extract the patient information number (PIN) field automatically from the film-scanned image using image analysis technique. To evaluate the PIN field extraction algorithm, 2 formats of label acquired from 2 different hospitals are tested. Given the available films with no constraints on the way the labels are written and positioned, the correct extraction rates are 73% and 84%, respectively. This extracted PIN information can link with Radiology Information System (RIS) or Hospital Information System (HIS), and the image scanned from the film then can be filed into the database automatically. The efficiency this method offers can simplify greatly the image filing process and improve the user friendliness of the overall image digitization system. Moreover, compared with the bar code reader, it solves the automatic information input problem in a very economical way. The authors believe the success of this technique will benefit the development of the PACS (Picture Archiving and Communication System) and teleradiology.

  18. Developments in digital radiography: an equipment update.

    PubMed

    James, J J; Davies, A G; Cowen, A R; O'Connor, P J

    2001-01-01

    Digital X-ray imaging technology has advanced rapidly over the past few years. This review, particularly aimed at those involved in using and purchasing such technology, is an attempt to unravel some of the complexities of this potentially confusing subject. The main groups of X-ray imaging devices that are considered are digitisers of conventional radiographs, image-intensifier-based fluorography systems, photostimulable phosphor computed radiography, amorphous selenium-based technology for thorax imaging and flat-panel systems. As well as describing these different systems, we look at ways of objectively assessing their image quality. Concepts that are used and explained include spatial resolution, grey-scale bit resolution, signal-to-noise ratio and detective quantum efficiency. An understanding of these basic parameters is vital in making a scientific assessment of a system's performance. Image processing and techniques are also briefly discussed, particularly with reference to their potential effects on image quality. This review aims to provide a basic understanding of digital X-ray imaging technology and enables the reader to make an independent and educated assessment of the relative merits of each system.

  19. Portable Digital Radiography and Computed Tomography Manual

    SciTech Connect

    Not Available

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  20. Beam Characterization at the Neutron Radiography Facility

    SciTech Connect

    Sarah Morgan; Jeffrey King

    2013-01-01

    The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

  1. A dose monitoring system for dental radiography

    PubMed Central

    Lee, Chena; Kim, Jo-Eun; Symkhampha, Khanthaly; Lee, Woo-Jin; Huh, Kyung-Hoe; Yi, Won-Jin; Heo, Min-Suk; Choi, Soon-Chul; Yeom, Heon-Young

    2016-01-01

    Purpose The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose. PMID:27358817

  2. Food consumption and digestion time estimation of spotted scat, Scatophagus argus, using X-radiography technique

    SciTech Connect

    Hashim, Marina; Abidin, Diana Atiqah Zainal; Das, Simon K.; Ghaffar, Mazlan Abd.

    2014-09-03

    The present study was conducted to investigate the food consumption pattern and gastric emptying time using x-radiography technique in scats fish, Scatophagus argus feeding to satiation in laboratory conditions. Prior to feeding experiment, fish of various sizes were examined their stomach volume, using freshly prepared stomachs ligatured at the tips of the burret, where the maximum amount of distilled water collected in the stomach were measured (ml). Stomach volume is correlated with maximum food intake (S{sub max}) and it can estimate the maximum stomach distension by allometric model i.e volume=0.0000089W{sup 2.93}. Gastric emptying time was estimated using a qualitative X-radiography technique, where the fish of various sizes were fed to satiation at different time since feeding. All the experimental fish was feed into satiation using radio-opaque barium sulphate (BaSO{sub 4}) paste injected in the wet shrimp in proportion to the body weight. The BaSO{sub 4} was found suitable to track the movement of feed/prey in the stomach over time and gastric emptying time of scats fish can be estimated. The results of qualitative X-Radiography observation of gastric motility, showed the fish (200 gm) that fed to maximum satiation meal (circa 11 gm) completely emptied their stomach within 30 - 36 hrs. The results of the present study will provide the first baseline information on the stomach volume, gastric emptying of scats fish in captivity.

  3. Food consumption and digestion time estimation of spotted scat, Scatophagus argus, using X-radiography technique

    NASA Astrophysics Data System (ADS)

    Hashim, Marina; Abidin, Diana Atiqah Zainal; Das, Simon K.; Ghaffar, Mazlan Abd.

    2014-09-01

    The present study was conducted to investigate the food consumption pattern and gastric emptying time using x-radiography technique in scats fish, Scatophagus argus feeding to satiation in laboratory conditions. Prior to feeding experiment, fish of various sizes were examined their stomach volume, using freshly prepared stomachs ligatured at the tips of the burret, where the maximum amount of distilled water collected in the stomach were measured (ml). Stomach volume is correlated with maximum food intake (Smax) and it can estimate the maximum stomach distension by allometric model i.e volume=0.0000089W2.93. Gastric emptying time was estimated using a qualitative X-radiography technique, where the fish of various sizes were fed to satiation at different time since feeding. All the experimental fish was feed into satiation using radio-opaque barium sulphate (BaSO4) paste injected in the wet shrimp in proportion to the body weight. The BaSO4 was found suitable to track the movement of feed/prey in the stomach over time and gastric emptying time of scats fish can be estimated. The results of qualitative X-Radiography observation of gastric motility, showed the fish (200 gm) that fed to maximum satiation meal (circa 11 gm) completely emptied their stomach within 30 - 36 hrs. The results of the present study will provide the first baseline information on the stomach volume, gastric emptying of scats fish in captivity.

  4. Digital Radiography for Determination of Primary Tooth Length: In Vivo and Ex Vivo Studies

    PubMed Central

    Basso, Maria D.; Jeremias, Fabiano; Cordeiro, Rita C. L.; Santos-Pinto, Lourdes

    2015-01-01

    Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson's correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed (P ≤ 0.48) between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length. PMID:25802894

  5. Scale analysis using X-ray microfluorescence and computed radiography

    NASA Astrophysics Data System (ADS)

    Candeias, J. P.; de Oliveira, D. F.; dos Anjos, M. J.; Lopes, R. T.

    2014-02-01

    Scale deposits are the most common and most troublesome damage problems in the oil field and can occur in both production and injection wells. They occur because the minerals in produced water exceed their saturation limit as temperatures and pressures change. Scale can vary in appearance from hard crystalline material to soft, friable material and the deposits can contain other minerals and impurities such as paraffin, salt and iron. In severe conditions, scale creates a significant restriction, or even a plug, in the production tubing. This study was conducted to qualify the elements present in scale samples and quantify the thickness of the scale layer using synchrotron radiation micro-X-ray fluorescence (SRμXRF) and computed radiography (CR) techniques. The SRμXRF results showed that the elements found in the scale samples were strontium, barium, calcium, chromium, sulfur and iron. The CR analysis showed that the thickness of the scale layer was identified and quantified with accuracy. These results can help in the decision making about removing the deposited scale.

  6. A method to optimize the processing algorithm of a computed radiography system for chest radiography.

    PubMed

    Moore, C S; Liney, G P; Beavis, A W; Saunderson, J R

    2007-09-01

    A test methodology using an anthropomorphic-equivalent chest phantom is described for the optimization of the Agfa computed radiography "MUSICA" processing algorithm for chest radiography. The contrast-to-noise ratio (CNR) in the lung, heart and diaphragm regions of the phantom, and the "system modulation transfer function" (sMTF) in the lung region, were measured using test tools embedded in the phantom. Using these parameters the MUSICA processing algorithm was optimized with respect to low-contrast detectability and spatial resolution. Two optimum "MUSICA parameter sets" were derived respectively for maximizing the CNR and sMTF in each region of the phantom. Further work is required to find the relative importance of low-contrast detectability and spatial resolution in chest images, from which the definitive optimum MUSICA parameter set can then be derived. Prior to this further work, a compromised optimum MUSICA parameter set was applied to a range of clinical images. A group of experienced image evaluators scored these images alongside images produced from the same radiographs using the MUSICA parameter set in clinical use at the time. The compromised optimum MUSICA parameter set was shown to produce measurably better images.

  7. EOS imaging versus current radiography: A health technology assessment study

    PubMed Central

    Mahboub-Ahari, Alireza; Hajebrahimi, Sakineh; Yusefi, Mahmoud; Velayati, Ashraf

    2016-01-01

    Background: EOS is a 2D/3D muscle skeletal diagnostic imaging system. The device has been developed to produce a high quality 2D, full body radiographs in standing, sitting and squatting positions. Three dimensional images can be reconstructed via sterEOS software. This Health Technology Assessment study aimed to investigate efficacy, effectiveness and cost-effectiveness of new emerged EOS imaging system in comparison with conventional x-ray radiographic techniques. Methods: All cost and outcome data were assessed from Iran's Ministry of Health Perspective. Data for clinical effectiveness was extracted using a rigorous systematic review. As clinical outcomes the rate of x-ray emission and related quality of life were compared with Computed Radiography (CR) and Digital Radiography (DR). Standard costing method was conducted to find related direct medical costs. In order to examine robustness of the calculated Incremental Cost Effectiveness Ratios (ICERs) we used two-way sensitivity analysis. GDP Per capita of Islamic Republic of Iran (2012) adopted as cost-effectiveness threshold. Results: Review of related literature highlighted the lack of rigorous evidence for clinical outcomes. Ultra low dose EOS imaging device is known as a safe intervention because of FDA, CE and CSA certificates. The rate of emitted X-ray was 2 to 18 fold lower for EOS compared to the conventional techniques (p<0.001). The Incremental Cost Effectiveness Ratio for EOS relative to CR calculated $50706 in baseline analysis (the first scenario) and $50714, $9446 respectively for the second and third scenarios. Considering the value of neither $42146 as upper limit, nor the first neither the second scenario could pass the cost-effectiveness threshold for Iran. Conclusion: EOS imaging technique might not be considered as a cost-effective intervention in routine practice of health system, especially within in-patient wards. Scenario analysis shows that, only in an optimum condition such as lower

  8. Advanced Gastric Cancer Perforation Mimicking Abdominal Wall Abscess

    PubMed Central

    Cho, Jinbeom; Park, Ilyoung; Lee, Dosang; Sung, Kiyoung; Baek, Jongmin

    2015-01-01

    Surgeons occasionally encounter a patient with a gastric cancer invading an adjacent organ, such as the pancreas, liver, or transverse colon. Although there is no established guideline for treatment of invasive gastric cancer, combined resection with radical gastrectomy is conventionally performed for curative purposes. We recently treated a patient with a large gastric cancer invading the abdominal wall, which was initially diagnosed as a simple abdominal wall abscess. Computed tomography showed that an abscess had formed adjacent to the greater curvature of the stomach. During surgery, we made an incision on the abdominal wall to drain the abscess, and performed curative total gastrectomy with partial excision of the involved abdominal wall. The patient received intensive treatment and wound management postoperatively with no surgery-related adverse events. However, the patient could not receive adjuvant chemotherapy and expired on the 82nd postoperative day. PMID:26468420

  9. [Perioperative pain management for abdominal and thoracic surgery].

    PubMed

    Englbrecht, J S; Pogatzki-Zahn, E M

    2014-06-01

    Abdominal and thoracic surgical procedures can result in significant acute postoperative pain. Present evidence shows that postoperative pain management remains inadequate especially after "minor" surgical procedures. Various therapeutic options including regional anesthesia techniques and systemic pharmacotherapy are available for effective treatment of postoperative pain. This work summarizes the pathophysiological background of postoperative pain after abdominal and thoracic surgery and discusses the indication, effectiveness, risks, and benefits of the different therapeutic options. Special focus is given to the controversial debate about the indication for epidural analgesia, as well as various alternative therapeutic options, including transversus abdominis plane (TAP) block, paravertebral block (PVB), wound infiltration with local anesthetics, and intravenous lidocaine. In additional, indications and contraindications of nonopioid analgesics after abdominal and thoracic surgery are discussed and recommendations based on scientific evidence and individual risk and benefit analysis are made. All therapeutic options discussed are eligible for clinical use and may contribute to improve postoperative pain outcome after abdominal and thoracic surgical procedures.

  10. Diagnostic ultrasonography in cattle with abdominal fat necrosis.

    PubMed

    Tharwat, Mohamed; Buczinski, Sébastien

    2012-01-01

    This study describes the ultrasonographic findings in 14 cows with abdominal fat necrosis. Ultrasonography of the abdomen revealed the presence of heterogeneous hyperechoic masses and hyperechoic omentum with localized masses floating in a hypoechoic peritoneal fluid. A hyperechogenic rim was imaged around both kidneys. The intestines were coated with hyperechoic capsules and the intestinal lumens were constricted. Ultrasonographic examination of the pancreatic parenchyma showed an overall increased echogenicity which was homogenously distributed in 3 cases. A diagnosis of abdominal fat necrosis was made with ultrasound-guided biopsy of the echogenic masses, and thereafter at postmortem examination. Results from this study demonstrate the efficacy of ultrasonography as an imaging modality for antemortem diagnosis of abdominal lipomatosis in cattle. To the authors' knowledge, this study is the first that illustrates ultrasonographic findings in cattle affected with abdominal lipomatosis.

  11. Novel Molecular Imaging Approaches to Abdominal Aortic Aneurysm Risk Stratification.

    PubMed

    Toczek, Jakub; Meadows, Judith L; Sadeghi, Mehran M

    2016-01-01

    Selection of patients for abdominal aortic aneurysm repair is currently based on aneurysm size, growth rate, and symptoms. Molecular imaging of biological processes associated with aneurysm growth and rupture, for example, inflammation and matrix remodeling, could improve patient risk stratification and lead to a reduction in abdominal aortic aneurysm morbidity and mortality. (18)F-fluorodeoxyglucose-positron emission tomography and ultrasmall superparamagnetic particles of iron oxide magnetic resonance imaging are 2 novel approaches to abdominal aortic aneurysm imaging evaluated in clinical trials. A variety of other tracers, including those that target inflammatory cells and proteolytic enzymes (eg, integrin αvβ3 and matrix metalloproteinases), have proven effective in preclinical models of abdominal aortic aneurysm and show great potential for clinical translation.

  12. Ruptured abdominal aortic aneurysm and aortoiliac vein fistula.

    PubMed

    Gyoten, Takayuki; Doi, Toshio; Yamashita, Akio; Fukahara, Kazuaki; Kotoh, Keiju; Yoshimura, Naoki

    2015-05-01

    A 67-year-old man was admitted with severe abdominal pain and back pain. Computed tomography showed an infrarenal abdominal aortic aneurysm (8.4 × 8.3 cm) and a large retroperitoneal hematoma. Immediately afterwards, the patient suffered circulatory collapse and was rushed to the operating theater. A fistula communicating with the left iliac vein was found. It was repaired with a Dacron patch while balloon-tipped catheters controlled the bleeding. The abdominal aortic aneurysm was replaced with a bifurcated graft. The postoperative course was uneventful. There have been few reports of successful repair of a ruptured abdominal aortic aneurysm associated with aortoiliac arteriovenous fistula.

  13. Recent advances in fast neutron radiography for cargo inspection

    NASA Astrophysics Data System (ADS)

    Sowerby, B. D.; Tickner, J. R.

    2007-09-01

    Fast neutron radiography techniques are attractive for screening cargo for contraband such as narcotics and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to X-rays and they can be used to determine elemental composition. Compared to neutron interrogation techniques that measure secondary radiation (neutron or gamma-rays), neutron radiography systems are much more efficient and rapid and they are much more amenable to imaging. However, for neutron techniques to be successfully applied to cargo screening, they must demonstrate significant advantages over well-established X-ray techniques. This paper reviews recent developments and applications of fast neutron radiography for cargo inspection. These developments include a fast neutron and gamma-ray radiography system that utilizes a 14 MeV neutron generator as well as fast neutron resonance radiography systems that use variable energy quasi-monoenergetic neutrons and pulsed broad energy neutron beams. These systems will be discussed and compared with particular emphasis on user requirements, sources, detector systems, imaging ability and performance.

  14. A benchmark for comparison of dental radiography analysis algorithms.

    PubMed

    Wang, Ching-Wei; Huang, Cheng-Ta; Lee, Jia-Hong; Li, Chung-Hsing; Chang, Sheng-Wei; Siao, Ming-Jhih; Lai, Tat-Ming; Ibragimov, Bulat; Vrtovec, Tomaž; Ronneberger, Olaf; Fischer, Philipp; Cootes, Tim F; Lindner, Claudia

    2016-07-01

    Dental radiography plays an important role in clinical diagnosis, treatment and surgery. In recent years, efforts have been made on developing computerized dental X-ray image analysis systems for clinical usages. A novel framework for objective evaluation of automatic dental radiography analysis algorithms has been established under the auspices of the IEEE International Symposium on Biomedical Imaging 2015 Bitewing Radiography Caries Detection Challenge and Cephalometric X-ray Image Analysis Challenge. In this article, we present the datasets, methods and results of the challenge and lay down the principles for future uses of this benchmark. The main contributions of the challenge include the creation of the dental anatomy data repository of bitewing radiographs, the creation of the anatomical abnormality classification data repository of cephalometric radiographs, and the definition of objective quantitative evaluation for comparison and ranking of the algorithms. With this benchmark, seven automatic methods for analysing cephalometric X-ray image and two automatic methods for detecting bitewing radiography caries have been compared, and detailed quantitative evaluation results are presented in this paper. Based on the quantitative evaluation results, we believe automatic dental radiography analysis is still a challenging and unsolved problem. The datasets and the evaluation software will be made available to the research community, further encouraging future developments in this field. (http://www-o.ntust.edu.tw/~cweiwang/ISBI2015/).

  15. A maximum likelihood method for high resolution proton radiography/proton CT.

    PubMed

    Collins-Fekete, Charles-Antoine; Brousmiche, Sébastien; Portillo, Stephen K N; Beaulieu, Luc; Seco, Joao

    2016-12-07

    Multiple Coulomb scattering (MCS) is the largest contributor to blurring in proton imaging. In this work, we developed a maximum likelihood least squares estimator that improves proton radiography's spatial resolution. The water equivalent thickness (WET) through projections defined from the source to the detector pixels were estimated such that they maximizes the likelihood of the energy loss of every proton crossing the volume. The length spent in each projection was calculated through the optimized cubic spline path estimate. The proton radiographies were produced using Geant4 simulations. Three phantoms were studied here: a slanted cube in a tank of water to measure 2D spatial resolution, a voxelized head phantom for clinical performance evaluation as well as a parametric Catphan phantom (CTP528) for 3D spatial resolution. Two proton beam configurations were used: a parallel and a conical beam. Proton beams of 200 and 330 MeV were simulated to acquire the radiography. Spatial resolution is increased from 2.44 lp cm(-1) to 4.53 lp cm(-1) in the 200 MeV beam and from 3.49 lp cm(-1) to 5.76 lp cm(-1) in the 330 MeV beam. Beam configurations do not affect the reconstructed spatial resolution as investigated between a radiography acquired with the parallel (3.49 lp cm(-1) to 5.76 lp cm(-1)) or conical beam (from 3.49 lp cm(-1) to 5.56 lp cm(-1)). The improved images were then used as input in a photon tomography algorithm. The proton CT reconstruction of the Catphan phantom shows high spatial resolution (from 2.79 to 5.55 lp cm(-1) for the parallel beam and from 3.03 to 5.15 lp cm(-1) for the conical beam) and the reconstruction of the head phantom, although qualitative, shows high contrast in the gradient region. The proposed formulation of the optimization demonstrates serious potential to increase the spatial resolution (up by 65[Formula: see text]) in proton radiography and greatly accelerate proton computed tomography reconstruction.

  16. [Abdominal pregnancy care. Case report].

    PubMed

    Morales Hernández, Sara; Díaz Velázquez, Mary Flor; Puello Tamara, Edgardo; Morales Hernández, Jorge; Basavilvazo Rodríguez, Maria Antonia; Cruz Cruz, Polita del Rocío; Hernández Valencia, Marcelino

    2008-10-01

    Abdominal pregnancies are the implantation of gestation in some of the abdominal structures. This kind of pregnancies represents sevenfold maternal death risk than tubarian ectopic pregnancies, and 90-fold death risk than normal ones. Previous cases have erroneously reported as abscess in Douglas punch, and frequently result in obitus or postnatal deaths. We report a case of a patient with 27 years old, and diagnosis of 25.2 weeks of pregnancy, prior placenta and anhidramnios, referred due to difficult in uterine contour delimitation, easy palpation of fetal parts, cephalic pole in left hypochondrious and presence of mass in hypogastria, no delimitations, pain with mobilization, no transvaginal bleed and fetal movements. Interruption of pregnancy is decided by virtue of severe oligohidramnios, retardation in fetal intrabdominal growth, and recurrent maternal abdominal pain. Surgical intervention was carried out for resolution of the obstetrical event, in which was found ectopic abdominal pregnancy with bed placental in right uterine horn that corresponded to a pregnancy of 30 weeks of gestation. Abdominal pregnancy is still a challenge for obstetrics due to its diagnosis and treatment. Early diagnosis is oriented to prevent an intrabdominal hemorrhage that is the main maternal cause of mortality.

  17. Patient exposure trends in medical and dental radiography

    SciTech Connect

    Johnson, D.W.; Goetz, W.A.

    1986-01-01

    Patient exposure to medical and dental x rays has long been of interest to the radiological health community. With the cooperation of state and local agencies and professional groups, the Center for Devices and Radiological Health has conducted three major surveys of patient exposure to x rays. The latest of these surveys, the Nationwide Evaluation of X-ray Trends (NEXT), collected x-ray exposure data for each year starting in 1972. Two earlier studies, the 1964 and 1970 X-ray Exposure Studies collected x-ray data during the years these surveys were conducted. Exposure trends presented are based on results of all three studies. Major improvements in beam limitation are seen for medical and dental radiography. Since 1964, when the first nationwide survey was conducted, dental exposures have decreased about 75%. Decreases of up to one-third occurred in exposures for medical examinations. The current exposure data presented continue to show a wide variation in medical exposures. Also presented are organ doses for four organs (ovaries, testes, thyroid and active bone marrow).

  18. Optimization of the radiological protection of patients undergoing digital radiography.

    PubMed

    Zhang, Menglong; Chu, Cunkun

    2012-02-01

    Because of a much higher dynamic range of flat panel detectors, patient dose can vary without change of image quality being perceived by radiologists. This condition makes optimization (OT) of radiation protection undergoing digital radiography (DR) more complex, while a chance to reduced patient dose also exists. In this study, we evaluated the difference of patient radiation and image rejection before and after OT to identify if it is necessary to carry out an OT procedure in a routine task with DR. The study consisted of a measurement of the dose area product (DAP) and entrance surface dose (ESD) received by a reference group of patients for eight common radiographic procedures using the DR system before and after OT. Meanwhile image rejection data during two 2-month periods were collected and sorted according to reason. For every radiographic procedure, t tests showed significant difference in average ESD and DAP before and after OT (p < 0.005). The ESDs from most examinations before OT were three times higher than that after OT. For DAPs, the difference is more significant. Image rejection rate after OT is significantly lower than that before OT (χ (2) = 36.5, p < 0.005). The substantial reductions of dose after OT resulted from appropriate mAs and exposure field. For DR patient dose, less than recommended diagnostic reference level can meet quality criteria and clinic diagnosis.

  19. Correlation Assessment between Three-Dimensional Facial Soft Tissue Scan and Lateral Cephalometric Radiography in Orthodontic Diagnosis

    PubMed Central

    Zecca, Piero Antonio; Fastuca, Rosamaria; Beretta, Matteo; Caprioglio, Alberto; Macchi, Aldo

    2016-01-01

    Purpose. The aim of the present prospective study was to investigate correlations between 3D facial soft tissue scan and lateral cephalometric radiography measurements. Materials and Methods. The study sample comprised 312 subjects of Caucasian ethnic origin. Exclusion criteria were all the craniofacial anomalies, noticeable asymmetries, and previous or current orthodontic treatment. A cephalometric analysis was developed employing 11 soft tissue landmarks and 14 sagittal and 14 vertical angular measurements corresponding to skeletal cephalometric variables. Cephalometric analyses on lateral cephalometric radiographies were performed for all subjects. The measurements were analysed in terms of their reliability and gender-age specific differences. Then, the soft tissue values were analysed for any correlations with lateral cephalometric radiography variables using Pearson correlation coefficient analysis. Results. Low, medium, and high correlations were found for sagittal and vertical measurements. Sagittal measurements seemed to be more reliable in providing a soft tissue diagnosis than vertical measurements. Conclusions. Sagittal parameters seemed to be more reliable in providing a soft tissue diagnosis similar to lateral cephalometric radiography. Vertical soft tissue measurements meanwhile showed a little less correlation with the corresponding cephalometric values perhaps due to the low reproducibility of cranial base and mandibular landmarks. PMID:27313615

  20. Anatomical variations of mandibular canal detected by panoramic radiography and CT: a systematic review and meta-analysis

    PubMed Central

    Dutra, Kamile; Porporatti, André Luís; Mezzomo, Luis A; De Luca Canto, Graziela; Flores-Mir, Carlos; Corrêa, Márcio

    2016-01-01

    Objectives: To investigate the anatomical variations of the mandibular canal through assessment in situ, panoramic radiography, CT or CBCT and assess their frequency. Methods: Articles were selected from databases (Cochrane Library, LILACS, ProQuest, PubMed, Scopus, Web of Science and Google Scholar), articles without limitations of language, in which the main objective was to evaluate the frequency of bifurcation of the mandibular canal through assessment in situ, panoramic radiography, CT or CBCT were selected. A meta-analysis of prevalence using random effects was performed. Results: Using a selection process in two phases, 15 articles were identified, and a meta-analysis was conducted. The results from these meta-analyses showed that the overall prevalence of anatomical variations for in situ studies was 6.46%, and through assessment of panoramic radiography and CT or CBCT the overall prevalence shown was 4.20% and 16.25%, respectively. Conclusions: There are two types of variations of the mandibular canal: the retromolar canal and bifid mandibular canal. The frequency variations through assessing in situ, panoramic radiography and CT or CBCT were 6.46%, 4.20% and 16.25%, respectively. PMID:26576624

  1. Abdominal radiation causes bacterial translocation

    SciTech Connect

    Guzman-Stein, G.; Bonsack, M.; Liberty, J.; Delaney, J.P.

    1989-02-01

    The purpose of this study was to determine if a single dose of radiation to the rat abdomen leads to bacterial translocation into the mesenteric lymph nodes (MLN). A second issue addressed was whether translocation correlates with anatomic damage to the mucosa. The radiated group (1100 cGy) which received anesthesia also was compared with a control group and a third group which received anesthesia alone but no abdominal radiation. Abdominal radiation lead to 100% positive cultures of MLN between 12 hr and 4 days postradiation. Bacterial translocation was almost nonexistent in the control and anesthesia group. Signs of inflammation and ulceration of the intestinal mucosa were not seen until Day 3 postradiation. Mucosal damage was maximal by Day 4. Bacterial translocation onto the MLN after a single dose of abdominal radiation was not apparently dependent on anatomical, histologic damage of the mucosa.

  2. NEUTRON RADIOGRAPHY (NRAD) REACTOR 64-ELEMENT CORE UPGRADE

    SciTech Connect

    John D. Bess

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA (registered) (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The interim critical configuration developed during the core upgrade, which contains only 62 fuel elements, has been evaluated as an acceptable benchmark experiment. The final 64-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (approximately +/-1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  3. Limiting the use of routine radiography for acute ankle injuries.

    PubMed Central

    Cockshott, W. P.; Jenkin, J. K.; Pui, M.

    1983-01-01

    In the diagnosis of ankle injuries routine radiography is often productive. An international survey of the average number of radiographs made of injured ankles suggested that two projections are adequate to detect fractures. This was confirmed in a prospective study of 242 patients coming to a hospital emergency department with recent ankle injuries. All the fractures could be identified on an anteroposterior or a lateral projection, although some were more obvious on an oblique view. As well, all the fractures were associated with malleolar soft-tissue swelling. Thus, radiography for acute ankle injuries could safely be restricted to patients with soft-tissue swelling, and fractures could be diagnosed using only two routine projections, though for management purposes additional projections might be needed. With a policy of limiting the use of radiography substantial cost reductions are possible. Images FIG. 1 PMID:6407744

  4. Studies of solid propellant combustion with pulsed radiography

    NASA Technical Reports Server (NTRS)

    Godai, T.; Tanemura, T.; Fujiwara, T.; Shimizu, M.

    1987-01-01

    Pulsed radiography was applied to observe solid propellant surface regression during rocket motor operation. Using a 150 KV flash X-ray system manufactured by the Field Emission Corporation and two kinds of film suppliers, images of the propellant surface of a 5 cm diameter end burning rocket motor were recorded on film. The repetition frame rate of 8 pulses per second and the pulse train length of 10 pulses are limited by the capability of the power supply and the heat build up within the X-ray tube, respectively. The experiment demonstrated the effectiveness of pulsed radiography for observing solid propellant surface regression. Measuring the position of burning surface images on film with a microdensitometer, quasi-instantaneous burning rate as a function of pressure and the variation of characteristic velocity with pressure and gas stay time were obtained. Other research items to which pulsed radiography can be applied are also suggested.

  5. Pressure Indication of 3013 Inner Containers Using Digital Radiography

    SciTech Connect

    HENSEL, SJ

    2004-04-15

    Plutonium bearing materials packaged for long term storage per the Department of Energy Standard 3013 (DOE-STD-3013) are required to be examined periodically in a non-destructive manner (i.e. without compromising the storage containers) for pressure buildup. Radiography is the preferred technology for performing the examinations. The concept is to measure and record the container lid position. As a can pressurizes the lid will deflect outward and thus provide an indication of the internal pressure. A radiograph generated within 30 days of creation of each storage container serves as the baseline from which future surveillance examinations will be compared. A problem with measuring the lid position was discovered during testing of a digital radiography system. The solution was to provide a distinct feature upon the lower surface of the container lid from which the digital radiography system could easily track the lid position.

  6. Abdominal Bloating: Pathophysiology and Treatment

    PubMed Central

    Seo, A Young; Oh, Dong Hyun

    2013-01-01

    Abdominal bloating is a very common and troublesome symptom of all ages, but it has not been fully understood to date. Bloating is usually associated with functional gastrointestinal disorders or organic diseases, but it may also appear alone. The pathophysiology of bloating remains ambiguous, although some evidences support the potential mechanisms, including gut hypersensitivity, impaired gas handling, altered gut microbiota, and abnormal abdominal-phrenic reflexes. Owing to the insufficient understanding of these mechanisms, the available therapeutic options are limited. However, medical treatment with some prokinetics, rifaximin, lubiprostone and linaclotide could be considered in the treatment of bloating. In addition, dietary intervention is important in relieving symptom in patients with bloating. PMID:24199004

  7. [Gallstone ileus. Abdominal CT usefulness].

    PubMed

    Sukkarieh, F; Brasseur, P; Bissen, L

    2004-06-01

    The authors report the case of a 93-year old woman referred to the emergency department and presenting with an intestinal obstruction. Abdominal CT reveals a biliary ileus caused by the migration and the impaction of a 3 cm gallstone in the small bowel. Surgical treatment by enterolithotomy was successful. In over 90% of cases, gallstone ileus is a complication of cholelithiasis and accounts for 25% of intestinal obstruction in patients over 65 years. To reduce morbidity and mortality, early diagnosis and prompt treatment are essential. Abdominal CT-scan is the gold standard technique.

  8. Abdominal obesity and metabolic syndrome.

    PubMed

    Després, Jean-Pierre; Lemieux, Isabelle

    2006-12-14

    Metabolic syndrome is associated with abdominal obesity, blood lipid disorders, inflammation, insulin resistance or full-blown diabetes, and increased risk of developing cardiovascular disease. Proposed criteria for identifying patients with metabolic syndrome have contributed greatly to preventive medicine, but the value of metabolic syndrome as a scientific concept remains controversial. The presence of metabolic syndrome alone cannot predict global cardiovascular disease risk. But abdominal obesity - the most prevalent manifestation of metabolic syndrome - is a marker of 'dysfunctional adipose tissue', and is of central importance in clinical diagnosis. Better risk assessment algorithms are needed to quantify diabetes and cardiovascular disease risk on a global scale.

  9. Abdominal surgery in neonatal foals.

    PubMed

    Bryant, James E; Gaughan, Earl M

    2005-08-01

    Abdominal surgery in foals under 30 days old has become more common with improved neonatal care. Early recognition of a foal at risk and better nursing care have increased the survival rates of foals that require neonatal care. The success of improved neonatal care also has increased the need for accurate diagnosis and treatment of gastrointestinal, umbilical, and bladder disorders in these foals. This chapter focuses on the early and accurate diagnosis of specific disorders that require abdominal exploratory surgery and the specific treatment considerations and prognosis for these disorders.

  10. Phosphor plate radiography: an integral component of the filmless practice.

    PubMed

    Benjamin, Scott

    2010-11-01

    The federal government has mandated that all dental and medical patient records be electronic in 3 years. Practices using film radiography will be unable to comply with this mandate. PSP radiography is not only a surprisingly convenient way to transition from film to digital imaging, it can also greatly enhance the practice's productivity, profitability, and patient satisfaction. Modern, forward-thinking practices will want to take full advantage of PSP's superiority by making this transition now rather than waiting until they are forced to.

  11. Californium Multiplier Part I: design for neutron radiography

    SciTech Connect

    Crosbie, K.L.; Preskitt, C.A.; John, J.; Hastings, J.D.

    1982-01-01

    The Californium Multiplier (CFX) is a subcritical assembly of enriched uranium surrounding a californium-252 neutron source. The function of the CFX is to multiply the neutrons emitted by the source to a number sufficient for neutron radiography. The CFX is designed to provide a collimated beam of thermal neutrons from which the gamma radiation is filtered, and the scattered neutrons are reduced to make it suitable for high resolution radiography. The entire system has inherent safety features, which provide for system and personnel safety, and it operates at moderate cost. In Part I, the CFX and the theory of its operation are described in detail.

  12. Proton radiography, nuclear cross sections and multiple Coulomb scattering

    SciTech Connect

    Sjue, Sky K.

    2015-11-04

    The principles behind proton radiography including multiple Coulomb scattering are discussed for a purely imaginary square well nucleus in the eikonal approximation. It is found that a very crude model can reproduce the angular dependence of the cross sections measured at 24 GeV/c. The largest differences are ~3% for the 4.56 mrad data, and ~4% for the 6.68 mrad data. The prospect of understanding how to model deterministically high-energy proton radiography over a very large range of energies is promising, but it should be tested more thoroughly.

  13. High contrast neutron radiography with optical devices in Kyoto University reactor

    NASA Astrophysics Data System (ADS)

    Kawabata, Y.; Nakano, T.; Hino, M.; Sunohara, H.; Matsushima, U.; Takenaka, N.

    2004-08-01

    The high-contrast neutron radiography has been performed at a VCN guide (VCN) and a supermirror cold neutron guide (CN-3) in Kyoto University Reactor. The large absorption cross-section of very low-energy neutrons can show a slight change of sample which thermal neutrons can not show. The effectiveness is shown in the fields of botany, agriculture and industrial researches. A new spectrum change option using high Qc supermirror ( m=4) is attached. It can change the upper limit of the energy of exposure neutrons by reflections, and gives a high flexibility of the experimental condition.

  14. Measuring microfocal spots using digital radiography

    SciTech Connect

    Fry, David A; Ewert, Uwe

    2009-01-01

    Measurement of microfocus spot size can be important for several reasons: (1) Quality assurance during manufacture of microfocus tubes; (2) Tracking performance and stability of microfocus tubes; (3) Determining magnification is especially important for digital radiography where the native spatial resolution of the digital system is not adequate for the application; and (4) Knowledge of unsharpness from the focal spot alone. The European Standard EN 12543-5 is based on a simple geometrical method of calculating focal spot size from unsharpness of high magnification film radiographs. The following equations are used for the focal spot size measurement: By similar triangles the following equations are presupposed: f/a = U/b and M = (a+b)/a. These equations can be combined to yield the well known expression: U = f(M - 1). Solving for f, f = U/(M-1). Therefore, the focal spot size, f, can be calculated by measuring the radiographic unsharpness and magnification of a known object. This is the basis for these tests. The European standard actually uses one-half of the unsharpness (which are then added together) from both sides of the object to avoid additional unsharpness contributions due to edge transmission unsharpness of the round test object (the outside of the object is measured). So the equation becomes f = (1/2 U{sub 1} + 1/2 U{sub 2})/(M-1). In practice 1/2 U is measured from the 50% to the 90% signal points on the transition profile from ''black'' to ''white,'' (positive image) or attenuated to unattenuated portion of the image. The 50% to 90% points are chosen as a best fit to an assumed Gaussian radiation distribution from the focal spot and to avoid edge transmission effects. 1/2 U{sub 1} + 1/2 U{sub 2} corresponds about to the full width at half height of a Gaussian focal spot. A highly absorbing material (Tungsten, Tungsten Alloy, or Platinum) is used for the object. Either wires or a sphere are used as the object to eliminate alignment issues. One

  15. 42 CFR 37.51 - Interpreting and classifying chest radiographs-digital radiography systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-digital radiography systems. 37.51 Section 37.51 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH... of Chest Radiographs § 37.51 Interpreting and classifying chest radiographs—digital radiography systems. (a) For each chest radiograph obtained at an approved facility using a digital radiography...

  16. Abdominal and hepatic uptake of /sup 99m/Tc-pyrophosphate in neonatal necrotizing enterocolitis

    SciTech Connect

    Caride, V.J.; Touloukian, R.J.; Ablow, R.C.; Lange, R.C.; Matthews, T.

    1981-04-01

    Abdominal /sup 99m/Tc-pyrophosphate (/sup 99m/Tc-PYP) scans were obtained in 15 neonates: 12 with neonatal necrotizing enterocolitis (NEC), two with osteomyelitis, and one with myocarditis. Ten of the babies with NEC had at least one positive scan; of these 10 studies, seven (Group A) showed both diffuse abdominal uptake and localized hepatic activity, two (Group B) showed abdominal uptake and questionable hepatic uptake, and one (Group C) demonstrated diffuse abdominal uptake only. The other two babies with NEC had normal scans (Group D). All NEC patients had normal scans. A patient with myocarditis had hepatic uptake of /sup 99m/Tc-PYP while the abdominal scan in the two infants with osteomyelitis was normal. These preliminary observations suggest that further study of a relationship between abdominal scan findings and the course of NEC is warranted.

  17. Functional Abdominal Pain in Children

    MedlinePlus

    ... the child’s mood and emotions, and in turn cause depression and anxiety. Screening/Diagnosis Detailed information regarding the location of abdominal pain, the frequency (number of times per week) and ... about the cause, and will guide further testing. Other important pieces ...

  18. Abdominal Pain (Stomach Pain), Short-Term

    MedlinePlus

    ... myhealthfinder Immunization Schedules Nutrient Shortfall Questionnaire Abdominal Pain (Stomach Pain), Short-termJust about everyone has had a " ... time or another. But sudden severe abdominal pain (stomach pain), also called acute pain, shouldn't be ...

  19. Imaging of gastrointestinal and abdominal tuberculosis.

    PubMed

    Vanhoenacker, F M; De Backer, A I; Op de, Beeck B; Maes, M; Van Altena, R; Van Beckevoort, D; Kersemans, P; De Schepper, A M

    2004-03-01

    This article discusses the range of manifestations of tuberculosis (TB) of the abdomen, including involvement of the gastrointestinal tract, the peritoneum, mesentery, omentum, abdominal lymph nodes, solid abdominal organs, the genital system and the abdominal aorta. Abdominal TB is a diagnostic challenge, particularly when pulmonary TB is absent. It may mimic many other abdominal diseases, both clinically and radiologically. An early correct diagnosis, however, is important in order to ensure proper treatment and a favorable outcome. Modern imaging is a cornerstone in the early diagnosis of abdominal TB and may prevent unnecessary morbidity and mortality. Generally, CT appears to be the imaging modality of choice in the detection and assessment of abdominal tuberculosis, other than gastrointestinal TB. Barium studies remain superior for demonstrating mucosal intestinal lesions. Ultrasound may be used for follow-up to monitor therapy response. The diagnosis of abdominal TB should be considered if suggestive imaging findings are found in patients with a high index of suspicion.

  20. Abdominal pain - children under age 12

    MedlinePlus

    Stomach pain in children; Pain - abdomen - children; Abdominal cramps in children; Belly ache in children ... When your child complains of abdominal pain, see if they can describe ... kinds of pain: Generalized pain or pain over more than half ...

  1. Direct digital radiography versus conventional radiography – assessment of visibility of file length placed in the root canal: An in vitro study

    PubMed Central

    Ravi, Vaiyapuri; Lipee, Priyadarshini; Rao, Canagapalli Venkat Nakabushan; Lakshmikanthan, Lakshminarayanan

    2012-01-01

    Aim and Objective: To compare conventional and direct digital radiography (DDR) in working length measurement of the root canal and to assess the significance of the different enhancement modes provided by the software to visualize the file length. Materials and Methods: Access cavities were prepared in 30 extracted maxillary central incisors. Size 15 k-file was introduced into the canal till it was flush with the apical foramen. The working length was calculated as 0.5 mm less than the vernier caliper measured length of each file. The files were then sealed with resin at their respective lengths. Intraoral periapical radiographs and direct digital radiographs were taken. Vernier caliper was used to measure the file length in the periapical radiographs, and standard, positive conversion, and colorize modes were used with the CDR system. A multiple regression analysis was conducted to give an accurate analysis between the actual file length and the different groups. Results: There was no statistical significance between the different groups tested. The multiple regression analysis test showed that the positive and colorize modes more accurately corresponded to the actual file length. Conclusion: Both conventional radiography and DDR can be reliably used for working length determination. The positive and colorize modes enhancement features of DDR greatly improve the visual perception, leading to more accurate measurements. PMID:23066272

  2. Blunt traumatic abdominal wall disruption with evisceration

    PubMed Central

    McDaniel, Ellen; Stawicki, Stanislaw PA; Bahner, David P

    2011-01-01

    Blunt traumatic abdominal wall disruptions associated with evisceration are very rare. The authors describe a case of traumatic abdominal wall disruption with bowel evisceration that occurred after a middle-aged woman sustained direct focal blunt force impact to the lower abdomen. Abdominal exploration and surgical repair of the abdominal wall defect were performed, with good clinical outcome. A brief overview of literature pertinent to this rare trauma scenario is presented. PMID:22229144

  3. Isolated Abdominal Wall Metastasis of Endometrial Carcinoma

    PubMed Central

    Simões, Jorge; Gonçalves, Matilde; Matos, Isabel

    2014-01-01

    A woman in her mid-60s presented with a bulky mass on the anterior abdominal wall. She had a previous incidental diagnosis of endometrial adenocarcinoma FIGO stage IB following a vaginal hysterectomy. Physical exam and imaging revealed a well circumscribed bulging tumour at the umbilical region, measuring 10 × 9 × 9 cm, with overlying intact skin and subcutaneous tissue. Surgical resection was undertaken, and histological examination showed features of endometrial carcinoma. She began chemotherapy and is alive with no signs of recurrent disease one year after surgery. This case brings up to light an atypical location of a solitary metastasis of endometrial carcinoma. PMID:25349753

  4. Ultrasonography in the diagnosis of nasal bone fractures: a comparison with conventional radiography and computed tomography.

    PubMed

    Lee, In Sook; Lee, Jung-Hoon; Woo, Chang-Ki; Kim, Hak Jin; Sol, Yu Li; Song, Jong Woon; Cho, Kyu-Sup

    2016-02-01

    The purpose of this study was to evaluate and compare the diagnostic efficacy of ultrasonography (US) with radiography and multi-detector computed tomography (CT) for the detection of nasal bone fractures. Forty-one patients with a nasal bone fracture who underwent prospective US examinations were included. Plain radiographs and CT images were obtained on the day of trauma. For US examinations, radiologist used a linear array transducer (L17-5 MHz) in 24 patients and hockey-stick probe (L15-7 MHz) in 17. The bony component of the nose was divided into three parts (right and left lateral nasal walls, and midline of nasal bone). Fracture detection by three modalities was subjected to analysis. Furthermore, findings made by each modality were compared with intraoperative findings. Nasal bone fractures were located in the right lateral wall (n = 28), midline of nasal bone (n = 31), or left lateral wall (n = 31). For right and left lateral nasal walls, CT had greater sensitivity and specificity than US or radiography, and better agreed with intraoperative findings. However, for midline fractures of nasal bone, US had higher specificity, positive predictive value, and negative predictive value than CT. Although two US evaluations showed good agreements at all three sites, US findings obtained by the hockey-stick probe showed closer agreement with intraoperative findings for both lateral nasal wall and midline of nasal bone. Although CT showed higher sensitivity and specificity than US or radiography, US found to be helpful for evaluating the midline of nasal bone. Furthermore, for US examinations of the nasal bone, a smaller probe and higher frequency may be required.

  5. 10 CFR 34.13 - Specific license for industrial radiography.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... may affirm that all individuals acting as industrial radiographers will be certified in radiation... submits a description of the applicant's overall organizational structure as it applies to the...

  6. 10 CFR 34.13 - Specific license for industrial radiography.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... may affirm that all individuals acting as industrial radiographers will be certified in radiation... submits a description of the applicant's overall organizational structure as it applies to the...

  7. 10 CFR 34.13 - Specific license for industrial radiography.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... may affirm that all individuals acting as industrial radiographers will be certified in radiation... submits a description of the applicant's overall organizational structure as it applies to the...

  8. Beam Physics in X-Ray Radiography Facilities

    SciTech Connect

    Chen, Y J; Caporaso, G J; Chambers, F W; Falabella, S; Goldin, F J; Guethlein, G; Lauer, E L; McCarrick, J F; Neurath, R; Richardson, R A; Sampayan, S; Weir, J T

    2002-12-02

    Performance of x-ray radiography facilities requires focusing the electron beams to sub-millimeter spots on the x-ray converters. Ions extracted from a converter by impact of a high intensity beam can partially neutralize the beam space charge and change the final focusing system. We will discuss these ion effects and mitigation.

  9. Method and Apparatus for Computed Imaging Backscatter Radiography

    NASA Technical Reports Server (NTRS)

    Shedlock, Daniel (Inventor); Meng, Christopher (Inventor); Sabri, Nissia (Inventor); Dugan, Edward T. (Inventor); Jacobs, Alan M. (Inventor)

    2013-01-01

    Systems and methods of x-ray backscatter radiography are provided. A single-sided, non-destructive imaging technique utilizing x-ray radiation to image subsurface features is disclosed, capable of scanning a region using a fan beam aperture and gathering data using rotational motion.

  10. Radiography Capabilities for Matter-Radiation Interactions in Extremes

    SciTech Connect

    Walstrom, Peter Lowell; Garnett, Robert William; Chapman, Catherine A. B; Salazar, Harry Richard; Otoole, Joseph Alfred; Barber, Ronald L.; Gomez, Tony Simon

    2015-04-28

    The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electron and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.

  11. Common positioning errors in panoramic radiography: A review

    PubMed Central

    Rondon, Rafael Henrique Nunes; Pereira, Yamba Carla Lara

    2014-01-01

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body. PMID:24701452

  12. Point Scattered Function (PScF) for fast neutron radiography

    NASA Astrophysics Data System (ADS)

    Hassan, Mohamed H.

    2009-08-01

    Fast neutron radiography opened up a new range of possibilities to image extremely dense objects. The removal of the scattering effect is one of the most challenging problems in neutron imaging. Neutron scattering in fast neutron radiography did not receive much attention compared with X-ray and thermal neutron radiography. The purpose of this work is to investigate the behavior of the Point Scattered Function (PScF) as applied in fast neutron radiography. The PScF was calculated using MCNP as a spatial distribution of scattered neutrons over the detector surface for one emitting source element. Armament and explosives materials, namely, Rifle steel, brass, aluminum and trinitrotoluene (TNT) were simulated. Effect of various sample thickness and sample-to-detector distance were considered. Simulated sample geometries included a slab with varying thickness, a sphere with varying radii, and a cylinder with varying base radii. Different neutron sources, namely, Cf-252, DT as well as DD neutron sources were considered. Neutron beams with zero degree divergence angle; and beams with varying angles related to the normal to the source plane were simulated. Curve fitting of the obtained PScF, in the form of Gaussian function, were given to be used in future work using image restoration codes. Analytical representation of the height as well as the Full Width at Half Maximum (FWHM) of the obtained Gaussian functions eliminates the need to calculate the PScF for sample parameters that were not investigated in this study.

  13. Abdominal x-ray

    MedlinePlus

    ... a kidney stone Identify blockage in the intestine Locate an object that has been swallowed Help diagnose diseases, such as tumors or other conditions Normal Results The x-ray will show normal structures for a person your age. What Abnormal Results Mean Abnormal findings ...

  14. Thin object radiography with a 2.2 MeV pulsed power machine

    NASA Astrophysics Data System (ADS)

    Haines, T. J.; Danielson, J. R.; Smith, J.; Wood, W. M.

    2017-01-01

    An experimental series was performed at a pulsed-power 2.2 MeV flash radiography machine to determine the lower limits of its mass sensitivity. This machine uses a rod-pinch diode with accelerating potential of 2.2 MeV and 50 ns pulse duration. Tungsten, aluminium, and titanium rod anodes were used to tune the emitted bremsstrahlung spectrum; as well as aluminium and beryllium filter materials. Analysis of thin tantalum foils shows a mass sensitivity as low as 300

  15. Electromyographic investigation of abdominal exercises and the effects of fatigue.

    PubMed

    Robinson, Mark; Lees, Adrian; Barton, Gabor

    Abdominal exercises are widely used to develop the anterior muscles of the trunk. These exercises can be undertaken without the aid of equipment, but increasingly manufacturers are developing equipment which purportedly enhances the training effect for abdominal muscles. As there are many different products and exercises used for abdominal muscle development, it is likely that some are more effective than others. This study aimed to investigate the effectiveness of five commonly performed abdominal exercises. A second aim was to investigate the effects of fatigue on these exercises. Five different types of abdominal exercise [standard crunch (sit-up) with bent knees, gym ball crunch, crunch with 5 kg weight held behind the head, legs raised crunch and a commercially manufactured roller crunch] were examined using integrated surface electromyography (IEMG). The lower rectus abdominis (LRA), upper rectus abdominis (URA) and obliquus externus abdominis (EO) of 15 healthy male participants [age (mean +/- SD) 22.2 +/- 6.8 years; height 1.77 +/- 0.06 m; mass 79.3 +/- 10.7 kg] were monitored using a four-channel special purpose EMG data logger. Three trials of each exercise were performed in random order and normalized to enable comparisons between muscles and exercises. At a later date, ten participants were then re-tested when fresh and after a 30 min whole-body fatigue protocol that specifically targeted the abdominal muscles. Two exercises were evaluated, the abdominal roller crunch and legs raised crunch, which were judged to be the least and most effective, respectively, of the five exercises previously used. The normalized IEMG showed significant (p < 0.001) differences between exercises (gym ball crunch = 86.0 +/- 7.5%; legs raised crunch = 79.9 +/- 5.1%; 5 kg weight crunch = 65.1 +/- 13.4%; standard crunch = 56.2 +/- 3.2%; and roller crunch = 45.0 +/- 11.4%). Post-fatigue, the normalized mean IEMG for both exercises increased significantly (p < 0.05) for LRA and

  16. Brighter Screens for Nondestructive Digital X-ray Radiography

    SciTech Connect

    Miller, Jr., A. C.; Bell, Z. W.; Carpenter, D. A.

    2003-09-15

    Fine resolution, bright X-ray screens are needed for digital radiography and material characterization at the Y-12 National Security Complex (Y-12). Current technology is simply not adequate for transferring high-energy X-ray images to visible light for demanding digital applications. Low energy radiography and especially emerging tomographic technologies are severely hampered for Y-12 nondestructive evaluation (NDE) applications by dim screens with poor resolution. Also, the development of more advanced materials characterization techniques, such as electron backscatter diffraction (EBSD), is driven by a design agency desire for tighter specifications and more uniform materials. Brighter screens would allow us to probe materials on a finer scale, leading to a better understanding of material behavior. A number of X-ray screen materials were studied that would be suitable for direct replacement in existing digital imaging systems. Spectroscopic evaluations were first made for a several candidates and indicated that lutetium orthosilicate (LSO) would be a promising candidate for MeV images. A relative comparison of brightness at various energies was then completed which showed that cesium iodide (CsI) could increase brightness by over an order of magnitude. Since image quality is also important for better screens, the resolving capabilities of candidate materials were measured. Resolution measurements were completed at X-ray peak energies up to 420KeV with magnified optical imaging systems, and indicated that LSO and Industrial Quality Incorporated glass (IQI) exhibited higher resolution than the CsI screen. The results give a choice of materials that can be tailored to the particular test under consideration. If high-speed images are necessary and some resolution can be sacrificed, the CsI screen will be a good choice. The screen can be replaced by an IQI or LSO unit if higher resolution is needed later, for instance to focus in on a region of interest. A number of

  17. The influence of abdominal pigmentation on desiccation and ultraviolet resistance in two species of Drosophila.

    PubMed

    Matute, Daniel R; Harris, Alexandra

    2013-08-01

    Drosophila yakuba and D. santomea are sister species that differ in their levels of abdominal pigmentation; D. yakuba shows heavily pigmented posterior abdominal segments in both sexes, whereas D. santomea lacks dark pigment anywhere on its body. Using naturally collected lines, we demonstrate the existence of altitudinal variation in abdominal pigmentation in D. yakuba but not in D. santomea. We use the variation in pigmentation within D. yakuba and two body-color mutants in D. yakuba to elucidate selective advantage of differences in pigmentation. Our results indicate that although differences in abdominal pigmentation have no effect on desiccation resistance, lighter pigmentation confers ultraviolet radiation resistance in this pair of species.

  18. RADIOGRAPHIC AND ULTRASONOGRAPHIC ABDOMINAL ANATOMY IN CAPTIVE RING-TAILED LEMURS (LEMUR CATTA).

    PubMed

    Makungu, Modesta; du Plessis, Wencke M; Barrows, Michelle; Groenewald, Hermanus B; Koeppel, Katja N

    2016-06-01

    The ring-tailed lemur (Lemur catta) is primarily distributed in south and southwestern Madagascar. It is classified as an endangered species by the International Union for Conservation of Nature. Various abdominal diseases, such as hepatic lipidosis, intestinal ulcers, cystitis, urinary tract obstruction, and neoplasia (e.g., colonic adenocarcinoma and cholangiocarcinoma), have been reported in this species. The aim of this study was to describe the normal radiographic and ultrasonographic abdominal anatomy in captive ring-tailed lemurs to provide guidance for clinical use. Radiography of the abdomen and ultrasonography of the liver, spleen, kidneys, and urinary bladder were performed in 13 and 9 healthy captive ring-tailed lemurs, respectively, during their annual health examinations. Normal radiographic and ultrasonographic reference ranges for abdominal organs were established and ratios were calculated. The majority (12/13) of animals had seven lumbar vertebrae. The sacrum had mainly (12/13) three segments. Abdominal serosal detail was excellent in all animals, and hypaxial muscles were conspicuous in the majority (11/13) of animals. The spleen was frequently (12/13) seen on the ventrodorsal (VD) view and rarely (3/13) on the right lateral (RL) view. The liver was less prominent and well contained within the ribcage. The pylorus was mostly (11/13) located to the right of the midline. The right and left kidneys were visible on the RL and VD views, with the right kidney positioned more cranial and dorsal to the left kidney. On ultrasonography, the kidneys appeared ovoid on transverse and longitudinal views. The medulla was hypoechoic to the renal cortex. The renal cortex was frequently (8/9) isoechoic and rarely (1/9) hyperechoic to the splenic parenchyma. The liver parenchyma was hypoechoic (5/5) to the renal cortex. Knowledge of the normal radiographic and ultrasonographic abdominal anatomy of ring-tailed lemurs may be useful in the diagnosis of diseases and in

  19. Predominance of Abdominal Visceral Adipose Tissue Reflects the Presence of Aortic Valve Calcification.

    PubMed

    Oikawa, Masayoshi; Owada, Takashi; Yamauchi, Hiroyuki; Misaka, Tomofumi; Machii, Hirofumi; Yamaki, Takayoshi; Sugimoto, Koichi; Kunii, Hiroyuki; Nakazato, Kazuhiko; Suzuki, Hitoshi; Saitoh, Shu-Ichi; Takeishi, Yasuchika

    2016-01-01

    Background. Aortic valve calcification (AVC) is a common feature of aging and is related to coronary artery disease. Although abdominal visceral adipose tissue (VAT) plays fundamental roles in coronary artery disease, the relationship between abdominal VAT and AVC is not fully understood. Methods. We investigated 259 patients who underwent cardiac and abdominal computed tomography (CT). AVC was defined as calcified lesion on the aortic valve by CT. %abdominal VAT was calculated as abdominal VAT area/total adipose tissue area. Results. AVC was detected in 75 patients, and these patients showed higher %abdominal VAT (44% versus 38%, p < 0.05) compared to those without AVC. When the cutoff value of %abdominal VAT was set at 40.9%, the area under the curve to diagnose AVC was 0.626. Multivariable logistic regression analysis showed that age (OR 1.120, 95% CI 1.078-1.168, p < 0.01), diabetes (OR 2.587, 95% CI 1.323-5.130, p < 0.01), and %abdominal VAT (OR 1.032, 95% CI 1.003-1.065, p < 0.05) were independent risk factors for AVC. The net reclassification improvement value for detecting AVC was increased when %abdominal VAT was added to the model: 0.5093 (95% CI 0.2489-0.7697, p < 0.01). Conclusion. We determined that predominance of VAT is associated with AVC.

  20. Automatic readout for nuclear emulsions in muon radiography of volcanoes

    NASA Astrophysics Data System (ADS)

    Aleksandrov, A.; Bozza, C.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; Di Crescenzo, A.; Di Marco, N.; Kose, U.; Lauria, A.; Medinaceli, E.; Miyamoto, S.; Montesi, C.; Pupilli, F.; Rescigno, R.; Russo, A.; Sirignano, C.; Stellacci, S. M.; Strolin, P.; Tioukov, V.

    2012-04-01

    Nuclear emulsions are an effective choice in many scenarios of volcano radiography by cosmic-ray muons. They are cheap and emulsion-based detectors require no on-site power supply. Nuclear emulsion films provide sub-micrometric tracking precision and intrinsic angular accuracy better than 1 mrad. Imaging the inner structure of a volcano requires that the cosmic-ray absorption map be measured on wide angular range. High-absorption directions can be probed by allowing for large statistics, which implies a large overall flux, i.e. wide surface for the detector. A total area of the order of a few m2 is nowadays typical, thanks to the automatic readout tools originally developed for high-energy physics experiments such as CHORUS, PEANUT, OPERA. The European Scanning System is now being used to read out nuclear emulsion films exposed to cosmic rays on the side of volcanoes. The structure of the system is described in detail with respect to both hardware and software. Its present scanning speed of 20 cm2/h/side/microscope is suitable to fulfil the needs of the current exposures of nuclear emulsion films for muon radiograph, but it is worth to notice that applications in volcano imaging are among the driving forces pushing to increase the performances of the system. Preliminary results for the Unzen volcano of a joint effort by research groups in Italy and Japan show that the current system is already able to provide signal/background ratio in the range 100÷10000:1, depending on the quality cuts set in the off-line data analysis. The size of the smallest detectable structures in that experimental setup is constrained by the available statistics in the region of highest absorption to about 50 mrad, or 22 m under the top of the mountain. Another exposure is currently taking data at the Stromboli volcano. Readout of the exposed films is expected to begin in March 2012, and preliminary results will be available soon after. An effort by several universities and INFN has

  1. Application of gamma-ray radiography and gravimetric measurements after accelerated corrosion tests of steel embedded in mortar

    SciTech Connect

    Duffó, Gustavo; Gaillard, Natalia; Mariscotti, Mario; Ruffolo, Marcelo

    2015-08-15

    The accelerated corrosion by the impressed current technique is widely used in studies of concrete durability since it has the advantage that tests can be carried out within reasonable periods of time. In the present work the relationship between the applied current density and the resulting damage on the reinforcing steel, by applying optical microscopy, scanning electron microscopy, gamma-ray radiography and gravimetric measurements, was studied by means of the implementation of accelerated corrosion tests on reinforced mortar. The results show that the efficiency of the applied current is between 1 and 77%, regardless of the applied current density, the water/cement ratio and the mortar cover depth of the specimens. The results show the applicability of the gamma-ray radiography technique to detect localized corrosion of steel rebars in laboratory specimens.

  2. A maximum likelihood method for high resolution proton radiography/proton CT

    NASA Astrophysics Data System (ADS)

    Collins-Fekete, Charles-Antoine; Brousmiche, Sébastien; Portillo, Stephen K. N.; Beaulieu, Luc; Seco, Joao

    2016-12-01

    Multiple Coulomb scattering (MCS) is the largest contributor to blurring in proton imaging. In this work, we developed a maximum likelihood least squares estimator that improves proton radiography’s spatial resolution. The water equivalent thickness (WET) through projections defined from the source to the detector pixels were estimated such that they maximizes the likelihood of the energy loss of every proton crossing the volume. The length spent in each projection was calculated through the optimized cubic spline path estimate. The proton radiographies were produced using Geant4 simulations. Three phantoms were studied here: a slanted cube in a tank of water to measure 2D spatial resolution, a voxelized head phantom for clinical performance evaluation as well as a parametric Catphan phantom (CTP528) for 3D spatial resolution. Two proton beam configurations were used: a parallel and a conical beam. Proton beams of 200 and 330 MeV were simulated to acquire the radiography. Spatial resolution is increased from 2.44 lp cm-1 to 4.53 lp cm-1 in the 200 MeV beam and from 3.49 lp cm-1 to 5.76 lp cm-1 in the 330 MeV beam. Beam configurations do not affect the reconstructed spatial resolution as investigated between a radiography acquired with the parallel (3.49 lp cm-1 to 5.76 lp cm-1) or conical beam (from 3.49 lp cm-1 to 5.56 lp cm-1). The improved images were then used as input in a photon tomography algorithm. The proton CT reconstruction of the Catphan phantom shows high spatial resolution (from 2.79 to 5.55 lp cm-1 for the parallel beam and from 3.03 to 5.15 lp cm-1 for the conical beam) and the reconstruction of the head phantom, although qualitative, shows high contrast in the gradient region. The proposed formulation of the optimization demonstrates serious potential to increase the spatial resolution (up by 65 % ) in proton radiography and greatly accelerate proton computed tomography reconstruction.

  3. Imaging of plantar fascia disorders: findings on plain radiography, ultrasound and magnetic resonance imaging.

    PubMed

    Draghi, Ferdinando; Gitto, Salvatore; Bortolotto, Chandra; Draghi, Anna Guja; Ori Belometti, Gioia

    2017-02-01

    Plantar fascia (PF) disorders commonly cause heel pain and disability in the general population. Imaging is often required to confirm diagnosis. This review article aims to provide simple and systematic guidelines for imaging assessment of PF disease, focussing on key findings detectable on plain radiography, ultrasound and magnetic resonance imaging (MRI). Sonographic characteristics of plantar fasciitis include PF thickening, loss of fibrillar structure, perifascial collections, calcifications and hyperaemia on Doppler imaging. Thickening and signal changes in the PF as well as oedema of adjacent soft tissues and bone marrow can be assessed on MRI. Radiographic findings of plantar fasciitis include PF thickening, cortical irregularities and abnormalities in the fat pad located deep below the PF. Plantar fibromatosis appears as well-demarcated, nodular thickenings that are iso-hypoechoic on ultrasound and show low-signal intensity on MRI. PF tears present with partial or complete fibre interruption on both ultrasound and MRI. Imaging description of further PF disorders, including xanthoma, diabetic fascial disease, foreign-body reactions and plantar infections, is detailed in the main text. Ultrasound and MRI should be considered as first- and second-line modalities for assessment of PF disorders, respectively. Indirect findings of PF disease can be ruled out on plain radiography. Teaching Points • PF disorders commonly cause heel pain and disability in the general population.• Imaging is often required to confirm diagnosis or reveal concomitant injuries.• Ultrasound and MRI respectively represent the first- and second-line modalities for diagnosis.• Indirect findings of PF disease can be ruled out on plain radiography.

  4. Water Calibration Measurements for Neutron Radiography: Application to Water Content Quantification in Porous Media

    SciTech Connect

    Kang, Misun; Bilheux, Hassina Z; Voisin, Sophie; Cheng, Chu-lin; Perfect, Edmund; Horita, Juske; Warren, Jeffrey

    2013-04-01

    Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 2 mm when the water calibration cells were positioned close to the face of the detector / scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

  5. Water calibration measurements for neutron radiography: Application to water content quantification in porous media

    NASA Astrophysics Data System (ADS)

    Kang, M.; Bilheux, H. Z.; Voisin, S.; Cheng, C. L.; Perfect, E.; Horita, J.; Warren, J. M.

    2013-04-01

    Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 0.2 cm when the water calibration cells were positioned close to the face of the detector/scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

  6. Digital Radiography of Mammographic Phantoms and Biologic Samples Using a 64 Microstrips Crystalline Silicon Detector Coupled to the RX64 ASIC

    SciTech Connect

    Leyva, A.; Cabal, A.; Pinera, I.; Abreu, Y.; Cruz, C. M.; Montano, L. M.; Diaz, C. C.; Fontaine, M.; Ortiz, C. M.; Padilla, F.; Mora, R. de la

    2008-08-11

    The present paper synthesizes the results obtained in the evaluation of a 64 microstrips crystalline silicon detector coupled to RX64 ASIC, designed for high-energy physics experiments, as a useful X-ray detector in advanced medical radiography, specifically in digital mammography. Research includes the acquisition of two-dimensional radiography of a mammography phantom using the scanning method, and the comparison of experimental profile with mathematically simulated one. The paper also shows the experimental images of three biological samples taken from breast biopsies, where it is possible to identify the presence of possible pathological tissues.

  7. Synthetic, biological and composite scaffolds for abdominal wall reconstruction.

    PubMed

    Meintjes, Jennifer; Yan, Sheng; Zhou, Lin; Zheng, Shusen; Zheng, Minghao

    2011-03-01

    The reconstruction of abdominal wall defects remains a huge surgical challenge. Tension-free repair is proven to be superior to suture repair in abdominal wall reconstruction. Scaffolds are essential for tension-free repair. They are used to bridge a defect or reinforce the abdominal wall. A huge variety of scaffolds are now commercially available. Most of the synthetic scaffolds are composed of polypropylene. They provide strong tissue reinforcement, but cause a foreign body reaction, which can result in serious complications. Absorbable synthetic scaffolds, such as Dexon™ (polyglycolic acid) and Vicryl™ (polyglactin 910), are not suitable for abdominal wall reconstruction as they usually require subsequent surgeries to repair recurrent hernias. Composite scaffolds combine the strength of nonabsorbable synthetic scaffolds with the antiadhesive properties of the absorbable scaffold, but require long-term follow-up. Biological scaffolds, such as Permacol™, Surgisis(®) and Alloderm(®), are derived from acellular mammalian tissues. Non-cross-linked biological scaffolds show excellent biocompatibility and degrade slowly over time. However, remnant DNA has been found in several products and the degradation leads to recurrence. Randomized controlled trials with long-term follow-up studies are lacking for all of the available scaffolds, particularly those derived from animal tissue. This article provides an overview of the different types of scaffolds available, and presents the key clinical studies of the commercially available synthetic, composite and biological scaffolds for abdominal wall reconstruction.

  8. Proton Radiography: Cross Section Measurements and Detector Development

    SciTech Connect

    Michael J. Longo; H. R. Gustafson: Durga Rajaram; Turgun Nigmanov

    2010-04-16

    Proton radiography has become an important tool for predicting the performance of stockpiled nuclear weapons. Current proton radiography experiments at LANSCE are confined to relatively small targets on the order of centimeters in size because of the low beam energy. LANL scientists have made radiographs with 12 and 24 GeV protons produced by the accelerator at Brookhaven National Laboratory. These energies are in the range required for hydrotest radiography. The design of a facility for hydrotest radiography requires knowledge of the cross sections for producing high-energy particles in the forward direction, which are incorporated into the Monte Carlo simulation used in designing the beam and detectors. There are few existing measurements of neutron production cross sections for proton-nuclei interactions in the 50 GeV range, and almost no data exist for forward neutron production, especially for heavy target nuclei. Thus the data from the MIPP EMCAL and HCAL, for which our group was responsible, are critical to proton radiography. Since neutrons and photons cannot be focused by magnets, they cause a background “fog” on the images. This problem can be minimized by careful design of the focusing system and detectors. The purpose of our research was to measure forward production of neutrons produced by high-energy proton beams striking a variety of targets. The forward-going particles carry most of the energy from a high-energy proton interaction, so these are the most important to proton radiography. This work was carried out in conjunction with the Fermilab E-907 (MIPP) collaboration. Our group was responsible for designing and building the E907 forward neutron and photon calorimeters. With the support of our Stewardship Science Academic Alliances grants, we were able to design, build, and commission the calorimeters on budget and ahead of schedule. The MIPP experiment accumulated a large amount of data in the first run that ended in early 2006. Our group has

  9. An Abdominal Aorta Wall Extraction for Liver Cirrhosis Classification Using Ultrasonic Images

    NASA Astrophysics Data System (ADS)

    Hayashi, Takaya; Fujita, Yusuke; Mitani, Yoshihiro; Hamamoto, Yoshihiko; Segawa, Makoto; Terai, Shuji; Sakaida, Isao

    2011-06-01

    We propose a method to extract an abdominal aorta wall from an M-mode image. Furthermore, we propose the use of a Gaussian filter in order to improve image quality. The experimental results show that the Gaussian filter is effective in the abdominal aorta wall extraction.

  10. Radiation dose reduction in digital radiography using wavelet-based image processing methods

    NASA Astrophysics Data System (ADS)

    Watanabe, Haruyuki; Tsai, Du-Yih; Lee, Yongbum; Matsuyama, Eri; Kojima, Katsuyuki

    2011-03-01

    In this paper, we investigate the effect of the use of wavelet transform for image processing on radiation dose reduction in computed radiography (CR), by measuring various physical characteristics of the wavelet-transformed images. Moreover, we propose a wavelet-based method for offering a possibility to reduce radiation dose while maintaining a clinically acceptable image quality. The proposed method integrates the advantages of a previously proposed technique, i.e., sigmoid-type transfer curve for wavelet coefficient weighting adjustment technique, as well as a wavelet soft-thresholding technique. The former can improve contrast and spatial resolution of CR images, the latter is able to improve the performance of image noise. In the investigation of physical characteristics, modulation transfer function, noise power spectrum, and contrast-to-noise ratio of CR images processed by the proposed method and other different methods were measured and compared. Furthermore, visual evaluation was performed using Scheffe's pair comparison method. Experimental results showed that the proposed method could improve overall image quality as compared to other methods. Our visual evaluation showed that an approximately 40% reduction in exposure dose might be achieved in hip joint radiography by using the proposed method.

  11. Refraction-Enhanced X-ray Radiography for Inertial Confinement Fusion and Laser-Produced Plasma Applications

    SciTech Connect

    Koch, J A; Landen, O L; Kozioziemski, B J; Izumi, N; Dewald, E L; Salmonson, J D; Hammel, B A

    2008-08-26

    We explore various laser-produced plasma and inertial-confinement fusion (ICF) applications of phase-contrast x-ray radiography, and we show how the main features of these enhancements can be considered from a geometrical optics perspective as refraction enhancements. This perspective simplifies the analysis, and often permits simple analytical formulae to be derived that predict the enhancements. We explore a raytrace approach to various material interface applications, and we explore a more general example of refractive bending of x-rays by an implosion plasma. We find that refraction-enhanced x-ray radiography of implosions may provide a means to quantify density differences across shock fronts as well as density variations caused by local heating due to high-Z dopants. We also point out that refractive bending by implosions plasmas can blur fine radiograph features, and can also provide misleading contrast information in area-backlit pinhole imaging experiments unless its effects are taken into consideration.

  12. Quantitative studies on inner interfaces in conical metal joints using hard x-ray inline phase contrast radiography

    NASA Astrophysics Data System (ADS)

    Zabler, S.; Rack, T.; Rack, A.; Nelson, K.

    2010-10-01

    Quantitative investigation of micrometer and submicrometer gaps between joining metal surfaces is applied to conical plug-socket connections in dental titanium implants. Microgaps of widths well beyond the resolving power of industrial x-ray systems are imaged by synchrotron phase contrast radiography. Furthermore, by using an analytical model for the relatively simple sample geometry and applying it to numerical forward simulations of the optical Fresnel propagation, we show that quantitative measurements of the microgap width down to 0.1 μm are possible. Image data recorded at the BAMline (BESSY-II light source, Germany) are presented, with the resolving power of the imaging system being 4 μm in absorption mode and ˜14 μm in phase contrast mode (z2=0.74 m). Thus, phase contrast radiography, combined with numerical forward simulations, is capable of measuring the widths of gaps that are two orders of magnitude thinner than the conventional detection limit.

  13. Dental radiography: efficacy in the assessment of intraosseous lesions of the face and jaws in asymptomatic patients

    SciTech Connect

    Zeichner, S.J.; Ruttimann, U.E.; Webber, R.L.

    1987-03-01

    In this investigation the efficacy of dental radiography for the detection of occult intraosseous lesions of the face and jaws was evaluated. An analysis of 30 million health insurance records indicated that the period prevalence of malignant lesions was less than 5 cases/million/year, and for benign lesions approximately 100 cases/million/year. Data from a controlled observer-performance study showed that radiographic sensitivities ranged between 50% and 80%. The cost per true-positive finding was estimated to be +8.6 million per malignant case and +430,000 per benign case. An assessment of the dosimetric literature indicated that the benefits of radiographic screening as a means for early detection of a malignancy appear to be counterbalanced by the risk of causing a radiation-induced malignancy. Taken together, these data demonstrate that dental radiography is not efficacious for the purpose of detecting occult lesions.

  14. A new scanner for in situ digital radiography of paintings

    NASA Astrophysics Data System (ADS)

    Impallaria, Anna; Evangelisti, Federico; Petrucci, Ferruccio; Tisato, Flavia; Castelli, Lisa; Taccetti, Francesco

    2016-12-01

    X-ray radiography is one of the most widely used imaging techniques in the field of cultural heritage, both for conservation and for investigation purposes. Performing radiographies in museums, thus avoiding movements of works of art, has been recently made easy by digital acquisition of images, but when the whole scan of a large painting is required, technical solutions for a portable device are still not at hand. The inherent weight of the X-ray tube and of the high-voltage generator makes the design of a portable device very difficult. In this project, the solution of the puzzle was separating devices devoted to different tasks, in order to maintain each item under 60 kg weight, thus being transportable with reasonable effort.

  15. Human performance analysis of industrial radiography radiation exposure events

    SciTech Connect

    Reece, W.J.; Hill, S.G.

    1995-12-01

    A set of radiation overexposure event reports were reviewed as part of a program to examine human performance in industrial radiography for the US Nuclear Regulatory Commission. Incident records for a seven year period were retrieved from an event database. Ninety-five exposure events were initially categorized and sorted for further analysis. Descriptive models were applied to a subset of severe overexposure events. Modeling included: (1) operational sequence tables to outline the key human actions and interactions with equipment, (2) human reliability event trees, (3) an application of an information processing failures model, and (4) an extrapolated use of the error influences and effects diagram. Results of the modeling analyses provided insights into the industrial radiography task and suggested areas for further action and study to decrease overexposures.

  16. Californium Multiplier. Part I. Design for neutron radiography

    SciTech Connect

    Crosbie, K.L.; Preskitt, C.A.; John, J.; Hastings, J.D.

    1982-04-01

    The Californium Multiplier (CFX) is a subcritical assembly of enriched uranium surrounding a californium-252 neutron source. The function of the CFX is to multiply the neutrons emitted by the source to a number sufficient for neutron radiography. The CFX is designed to provide a collimated beam of thermal neutrons from which the gamma radiation is filtered, and the scattered neutrons are reduced to make it suitable for high resolution radiography. The entire system has inherent safety features, which provide for system and personnel safety, and it operates at moderate cost. In Part I, the CFX and the theory of its operation are described in detail. Part II covers the performance of the Mound Facility CFX.

  17. Radiography and ultrasonic calculation workbooks: installation and use

    SciTech Connect

    Rikard, D; Dolan, K

    2000-03-24

    The radiography and ultrasonic calculation workbooks are intended to assist Level I, II and III NDE personnel in calculations used in routine job applications. These workbooks are an upgraded version of Microsoft Excel{reg_sign} spreadsheets, which were originally set up in October 1988, using a Macintosh Plus{reg_sign} computer and Microsoft Excel{reg_sign} version 1.5. A description of these was released as ''Computerized Calculations for Radiography and Ultrasonics'', UCRL-JC-105419 in November 1990 and published in Materials Evaluation, Volume 49/Number 4, in April 1991. Over the years as Microsoft improved the capabilities of the Excel program to include the abilities to make sketches and to have multiple tabbed pages in a document called a ''workbook'' we have now modified the calculation spreadsheets to include these enhancements. Following is a short description on how to install and use these workbooks on a Macintosh or PC.

  18. Proton radiography and tomography with application to proton therapy.

    PubMed

    Poludniowski, G; Allinson, N M; Evans, P M

    2015-09-01

    Proton radiography and tomography have long promised benefit for proton therapy. Their first suggestion was in the early 1960s and the first published proton radiographs and CT images appeared in the late 1960s and 1970s, respectively. More than just providing anatomical images, proton transmission imaging provides the potential for the more accurate estimation of stopping-power ratio inside a patient and hence improved treatment planning and verification. With the recent explosion in growth of clinical proton therapy facilities, the time is perhaps ripe for the imaging modality to come to the fore. Yet many technical challenges remain to be solved before proton CT scanners become commonplace in the clinic. Research and development in this field is currently more active than at any time with several prototype designs emerging. This review introduces the principles of proton radiography and tomography, their historical developments, the raft of modern prototype systems and the primary design issues.

  19. The MU-RAY detector for muon radiography of volcanoes

    NASA Astrophysics Data System (ADS)

    Anastasio, A.; Ambrosino, F.; Basta, D.; Bonechi, L.; Brianzi, M.; Bross, A.; Callier, S.; Caputo, A.; Ciaranfi, R.; Cimmino, L.; D'Alessandro, R.; D'Auria, L.; de La Taille, C.; Energico, S.; Garufi, F.; Giudicepietro, F.; Lauria, A.; Macedonio, G.; Martini, M.; Masone, V.; Mattone, C.; Montesi, M. C.; Noli, P.; Orazi, M.; Passeggio, G.; Peluso, R.; Pla-Dalmau, A.; Raux, L.; Rubinov, P.; Saracino, G.; Scarlini, E.; Scarpato, G.; Sekhniaidze, G.; Starodubtsev, O.; Strolin, P.; Taketa, A.; Tanaka, H. K. M.; Vanzanella, A.

    2013-12-01

    The MU-RAY detector has been designed to perform muon radiography of volcanoes. The possible use on the field introduces several constraints. First the electric power consumption must be reduced to the minimum, so that the detector can be solar-powered. Moreover it must be robust and transportable, for what concerns the front-end electronics and data acquisition. A 1 m2 prototype has been constructed and is taking data at Mt. Vesuvius. The detector consists of modules of 32 scintillator bars with wave length shifting fibers and silicon photomultiplier read-out. A dedicated front-end electronics has been developed, based on the SPIROC ASIC. An introduction to muon radiography principles, the MU-RAY detector description and results obtained in laboratory will be presented.

  20. Comparison of Digital Imaging Systems for Neutron Radiography

    NASA Astrophysics Data System (ADS)

    Pugliesi, R.; Pugliesi, Fábio; Stanojev Pereira, M. A.

    2011-09-01

    The characteristics of three digital imaging systems for neutron radiography purposes have been compared. Two of them make use of films, CR-39 and Kodak AA, and the third makes use of a LiF scintillator, for image registration. The irradiations were performed in the neutron radiography facility installed at the IEA-R1 nuclear research reactor of IPEN-CNEN/SP. According to the obtained results, the system based on CR-39 is the slowest to obtain an image, and the best in terms of resolution but the worse in terms of contrast. The system based on Kodak AA is faster than the prior, exhibits good resolution and contrast. The system based on the scintillator is the fastest to obtain an image, and best in terms of contrast but the worse in terms of resolution.

  1. Monte Carlo Modeling of High-Energy Film Radiography

    SciTech Connect

    Miller, A.C., Jr.; Cochran, J.L.; Lamberti, V.E.

    2003-03-28

    High-energy film radiography methods, adapted in the past to performing specific tasks, must now meet increasing demands to identify defects and perform critical measurements in a wide variety of manufacturing processes. Although film provides unequaled resolution for most components and assemblies, image quality must be enhanced with much more detailed information to identify problems and qualify features of interest inside manufactured items. The work described is concerned with improving current 9 MeV nondestructive practice by optimizing the important parameters involved in film radiography using computational methods. In order to follow important scattering effects produced by electrons, the Monte Carlo N-Particle (MCNP) transport code was used with advanced, highly parallel computer systems. The work has provided a more detailed understanding of latent image formation at high X-ray energies, and suggests that improvements can be made in our ability to identify defects and to obtain much more detail in images of fine features.

  2. Study of a Loop Heat Pipe Using Neutron Radiography

    SciTech Connect

    C. Thomas Conroy; A. A. El-Ganayni; David R. Riley; John M. Cimbala; Jack S. Brenizer, Jr.; Abel Po-Ya Chuang; Shane Hanna

    2001-08-01

    An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

  3. Dental radiography exposure of the Hiroshima and Nagasaki populations

    SciTech Connect

    Antoku, S.; Hoshi, M.; Russell, W.J.; Kihara, T.; Sawada, S.; Takeshita, K.; Otake, M.; Yoshinaga, H.; Beach, D.R.

    1989-03-01

    Dental radiography doses in Hiroshima and Nagasaki were estimated on the basis of survey data from dental hospitals and clinics in Hiroshima and Nagasaki, and doses were measured by thermoluminescent dosimeters and a phantom. Doses to organs, including the lens, pituitary fossa, thyroid gland, and skin were calculated from data obtained during a 2-week survey in both cities. The mean caput doses were calculated from the data indicating frequency per year and were tabulated by organs, age, teeth examined, type of examination, population, sex, and city. No significant difference was observed by age, population, sex, or city. Currently the doses incurred during dental radiography may not be sufficiently high to cause bias in the assessments for late radiation effects among atomic-bomb survivors. However, the mean caput thyroid doses of 62 mrad and 67 mrad in Hiroshima and Nagasaki, respectively, cannot be ignored from the standpoint of their potential in contributing to radiation-induced carcinogenesis.

  4. [Development of breathing chest radiography: study of exposure timing].

    PubMed

    Tanaka, Rie; Sanada, Shigeru; Kobayashi, Takeshi; Suzuki, Masayuki; Matsui, Takeshi; Inoue, Hitoshi

    2003-08-01

    The flat-panel detector (FPD) has been introduced into clinical practice. A modified FPD, which has the ability to obtain dynamic chest radiographs, was introduced into our hospital, and clinical testing is ongoing. Both the inspiratory and expiratory phases have to be included in dynamic chest radiographs. The purpose of this study was to investigate the most appropriate chest radiography signal for observation of the respiratory process. We prepared ten protocol patterns that differed in terms of respiratory phase at X-ray exposure, exposure duration, and signal multiplicity. We also performed preliminary experiments and administered several questionnaires to ten volunteers. The volunteers breathed according to vocal and visual signals, and their respiratory waves were recorded by spirometer. The most appropriate protocol was similar to the method used for conventional chest radiography.

  5. Proton radiography and tomography with application to proton therapy

    PubMed Central

    Allinson, N M; Evans, P M

    2015-01-01

    Proton radiography and tomography have long promised benefit for proton therapy. Their first suggestion was in the early 1960s and the first published proton radiographs and CT images appeared in the late 1960s and 1970s, respectively. More than just providing anatomical images, proton transmission imaging provides the potential for the more accurate estimation of stopping-power ratio inside a patient and hence improved treatment planning and verification. With the recent explosion in growth of clinical proton therapy facilities, the time is perhaps ripe for the imaging modality to come to the fore. Yet many technical challenges remain to be solved before proton CT scanners become commonplace in the clinic. Research and development in this field is currently more active than at any time with several prototype designs emerging. This review introduces the principles of proton radiography and tomography, their historical developments, the raft of modern prototype systems and the primary design issues. PMID:26043157

  6. An improved method for profile radiography of piping

    SciTech Connect

    Bell, M.S.; Haupt, J.D.

    1996-07-01

    The Petro-Chemical industry has used profile radiography for more than thirty years to find, and evaluate, corrosion in piping systems. The technique offers a method of ``seeing into`` a piece of pipe. This allows the inspector to see the ``whole picture``. Single point ultrasonic measurements cannot provide this degree of information. Shell`s objective for studying the use of this method centered on optimizing their profile radiography technique to improve accuracy and reproducibility of wall thickness measurements. Accuracy and reproducibility of measurements are particularly important when used to determine corrosion rates. To help achieve this objective, the authors developed an inspection procedure to minimize the more prominent sources of inaccuracies associated with this technique. Along with this procedure, they also developed an associated training program. All of Shell Oil`s Pressure Equipment inspectors and key contract employees have received this training.

  7. Study of a loop heat pipe using neutron radiography.

    PubMed

    Cimbala, John M; Brenizer, Jack S; Chuang, Abel Po-Ya; Hanna, Shane; Thomas Conroy, C; El-Ganayni, A A; Riley, David R

    2004-10-01

    An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

  8. Subtraction Radiography for the Diagnosis of Bone Lesions in Dogs.

    DTIC Science & Technology

    1984-05-31

    Avail ander Journal of Periodontology Dist Special Ř 211 East Chicago Avenue Room 924 Chicago, IL 60611 Dear Sirs: I m submitting an original...research article titled "Subtraction Radiography for the Diagnosis of Bone Lesions in Dogs" solely to the Journal of Periodontology for review and... clinical practice in our area. 60-70 Kvp would have produced more contrast in the radiographic films used for the conventional technique, but likely

  9. PyRAT - python radiography analysis tool (u)

    SciTech Connect

    Temple, Brian A; Buescher, Kevin L; Armstrong, Jerawan C

    2011-01-14

    PyRAT is a radiography analysis tool used to reconstruction images of unknown 1-0 objects. The tool is written in Python and developed for use on LINUX and Windows platforms. The tool is capable of performing nonlinear inversions of the images with minimal manual interaction in the optimization process. The tool utilizes the NOMAD mixed variable optimization tool to perform the optimization.

  10. Non-damaging, portable radiography: Applications in arms control verification

    SciTech Connect

    Morris, R.A.; Butterfield, K.B.; Apt, K.E.

    1992-08-01

    The state-of-the-technology necessary to perform portable radiography in support of arms control verification is evaluated. Specific requirements, such as accurate measurements of the location of features in a treaty-limited object and the detection of deeply imbedded features, are defined in three scenarios. Sources, detectors, portability, mensuration, and safety are discussed in relation to the scenarios. Examples are given of typical radiographic systems that would be capable of addressing the inspection problems associated with the three scenarios.

  11. X-Ray Radiography of Gas Turbine Ceramics.

    DTIC Science & Technology

    1979-10-20

    Microfocus X - ray equipment. 1a4ihe definition of equipment concepts for a computer assisted tomography (CAT) system; and 4ffthe development of a CAT...were obtained from these test coupons using Microfocus X - ray and image en- hancement techniques. A Computer Assisted Tomography (CAT) design concept...conventional ultrasonics (45 MHz), very high frequency ultrasonics (250 MHz), neutron radiography, Microfocus X - ray , image enhancement, microwave

  12. Leaded apron for use in panoramic dental radiography

    SciTech Connect

    Whitcher, B.L.; Gratt, B.M.; Sickles, E.A.

    1980-05-01

    The leaded aprons currently available for use during dental radiography do not protect the thyroid gland from radiation. Conventional aprons may produce artifacts when used with panoramic dental x-ray units. This study measures the dose reduction obtained with an experimental leaded apron designed for use with panoramic dental x-ray units. Skin exposures measured at the thyroid and at the sternum were reduced with the use of the apron. Films produced during the study were free from apron artifacts.

  13. Imaging Brunelleschi's cupola wall using muon scattering radiography

    SciTech Connect

    Guardincerri, Elena

    2015-09-16

    This PowerPoint presentation describes the cupola's structure and current reinforcements, reasoning behind why muon radiography would be helpful. A demonstration project is described where a similar wall was constructed to illustrate the potential benefits to Italian authorities; Requirements and a potential plan were created and collaboration to make it happen was deemed to be possible among LANL, Toshiba, the Parma and Florence Universities and the Opera del Duomo,

  14. The implementation of digital sensors in maxillofacial radiography

    NASA Astrophysics Data System (ADS)

    van der Stelt, Paul F.

    2001-03-01

    Systems for intra-oral digital radiography in dentistry can be divided into two main groups: direct sensor systems and semi-direct or indirect sensor systems. Direct imaging is performed by a two-dimensional array of sensor elements. The size of a typical intra-oral CCD-sensor is approximately from 18 mm×24 mm to 30 mm×40 mm; the active area is somewhat smaller, because of the thickness of the packaging of the sensor. CCD-based imaging is now also available for panoramic and cephalometric radiography. Indirect (semi-direct) imaging is based on storage phosphor plates (SPP) imaging. The plate is positioned in the mouth of the patient behind the teeth, and exposed to radiation. The positioning of the sensor plate resembles very much the way conventional radiographic films are handled. SPP technology is also available for panoramic and cephalometric imaging. The purpose of radiography is to provide information to solve a particular diagnostic task. It is therefore very likely that the role of dedicated diagnostic software will become essential in the near future. The importance of dedicated software for diagnostic imaging will increase. As a result of worldwide research, more procedures will become available, for research as well as for use in general practice.

  15. A New Neutron Radiography / Tomography / Imaging Station DINGO at OPAL

    NASA Astrophysics Data System (ADS)

    Garbe, U.; Randall, T.; Hughes, C.; Davidson, G.; Pangelis, S.; Kennedy, S. J.

    A new neutron radiography / tomography / imaging instrument DINGO was built to support the area of neutron imaging research (neutron radiography/tomography) at ANSTO. The instrument is designed for an international user community and for routine quality control for defense, industrial, cultural heritage and archaeology applications. In the industrial field it provides a useful tool for studying cracking and defects in steel or other metals. The instrument construction was completed at the end of June 2013 and it is currently in the hot commissioning stage. The usable neutron flux is mainly determined by the neutron source, but it depends on the instrument position and the resolution. The instrument position for DINGO is the thermal neutron beam port HB-2 in the reactor hall. The measured flux (using gold foil) for an L/D of approximately 500 at HB-2 is 5.3*107 [n/cm2s], which is in a similar range to other facilities. A special feature of DINGO is the in-pile collimator position in front of the main shutter at HB-2. The collimator offers two pinholes with a possible L/D of 500 and 1000. A secondary collimator separates the two beams by blocking one and positions another aperture for the other beam. The whole instrument operates in two different positions, one for high resolution and one for high speed. In the current configuration DINGO measured first radiography and tomography data sets on friendly user test samples.

  16. Detection of gastritis by single- and double-contrast radiography

    SciTech Connect

    Thoeni, R.F.; Goldberg, H.I.; Ominsky, S.; Cello, J.P.

    1983-09-01

    Sixty-eight patients with various types of gastritis, 23 patients with normal stomachs, and four patients with other gastric diseases were examined in a prospective study to assess the sensitivity and specificity of single-contrast (SC) and double-contrast (DC) upper gastrointestinal examinations in the evaluation of gastritis. All patients underwent endoscopy with biopsy followed first by DC and then by SC radiography. The respective sensitivities of SC and DC radiography were 58% and 72% for all examinations and 59% and 77% for adequate examinations only. The respective specificities were 59% and 55% based on all examinations. Useful radiographic features included polypoid defects and erosions detected by both methods, abnormal folds and flattened margins detected by the SC technique, and narrowed lumen and crenulated margins detected by the DC technique. In 93% of all cases, the correct diagnosis was based on two or more of these radiographic features. According to this study, the radiographic sensitivity in the detection of gastritis is reliable only in cases of moderate-to-severe disease and only when based on findings of the DC examination. Neither SC nor DC radiography should be used as the primary screening method for patients with suspected gastritis, and the radiographic diagnosis should be restricted to the terms ''erosive'' or ''nonerosive gastritis.''

  17. Proton radiography based on near-threshold Cerenkov radiation

    DOEpatents

    van Bibber, Karl A.; Dietrich, Frank S.

    2003-01-01

    A Cerenkov imaging system for charged particle radiography that determines the energy loss of the charged particle beam passing through an object. This energy loss information provides additional detail on target densities when used with traditional radiographic techniques like photon or x-ray radiography. In this invention a probe beam of 800 MeV to 50 GeV/c charged particles is passed through an object to be imaged, an imaging magnetic spectrometer, to a silicon aerogel Cerenkov radiator where the charged particles emitted Cerenkov light proportional to their velocity. At the same beam focal plane, a particle scintillator produces a light output proportional to the incident beam flux. Optical imaging systems relay the Cerenkov and scintillator information to CCD's or other measurement equipment. A ratio between the Cerenkov and scintillator is formed, which is directly proportional to the line density of the object for each pixel measured. By rotating the object, tomographic radiography may be performed. By applying pulses of beam, discrete time-step movies of dynamic objects may be made.

  18. Management of pediatric radiation dose using Agfa computed radiography.

    PubMed

    Schaetzing, R

    2004-10-01

    Radiation dose to patients and its management have become important considerations in modern radiographic imaging procedures, but they acquire particular significance in the imaging of children. Because of their longer life expectancy, children exposed to radiation are thought to have a significantly increased risk of radiation-related late sequelae compared to adults first exposed to radiation later in life. Therefore, current clinical thinking dictates that dose in pediatric radiography be minimized, while simultaneously ensuring sufficient diagnostic information in the image, and reducing the need for repeat exposures. Dose management obviously starts with characterization and control of the exposure technique. However, it extends farther through the imaging chain to the acquisition system, and even to the image processing techniques used to optimize acquired images for display. Further, other factors, such as quality control procedures and the ability to handle special pediatric procedures, like scoliosis exams, also come into play. The need for dose management in modern radiography systems has spawned a variety of different solutions, some of which are similar across different manufacturers, and some of which are unique. This paper covers the techniques used in Agfa Computed Radiography (CR) systems to manage dose in a pediatric environment.

  19. Advances in computed radiography systems and their physical imaging characteristics.

    PubMed

    Cowen, A R; Davies, A G; Kengyelics, S M

    2007-12-01

    Radiological imaging is progressing towards an all-digital future, across the spectrum of medical imaging techniques. Computed radiography (CR) has provided a ready pathway from screen film to digital radiography and a convenient entry point to PACS. This review briefly revisits the principles of modern CR systems and their physical imaging characteristics. Wide dynamic range and digital image enhancement are well-established benefits of CR, which lend themselves to improved image presentation and reduced rates of repeat exposures. However, in its original form CR offered limited scope for reducing the radiation dose per radiographic exposure, compared with screen film. Recent innovations in CR, including the use of dual-sided image readout and channelled storage phosphor have eased these concerns. For example, introduction of these technologies has improved detective quantum efficiency (DQE) by approximately 50 and 100%, respectively, compared with standard CR. As a result CR currently affords greater scope for reducing patient dose, and provides a more substantive challenge to the new solid-state, flat-panel, digital radiography detectors.

  20. A kinematic comparison of four abdominal training devices and a traditional abdominal crunch.

    PubMed

    Sands, William A; McNeal, Jeni R

    2002-02-01

    Abdominal exercises are often performed on roller or rocker mechanisms, which have been aggressively promoted through the television and print media. However, justifications are lacking as to why these devices are superior to traditional abdominal exercises such as crunches. This study sought to describe and compare the range of motion (ROM) of several joints during crunches performed on 4 different abdominal conditioning devices (2 roller and 2 pivot types) and a traditional crunch exercise. Ten men (29 +/- 5.87 years, 177.5 +/- 6.46 cm, 80.96 +/- 11.72 kg) and 10 women (33.4 +/- 10.16 years, 162.23 +/- 3.83 cm, 56.99 +/- 7.36 kg) subjects agreed to participate in the study. Subjects were videotaped in the sagittal plane (60 Hz) using standard kinematic methods. Reflective markers were placed on the right temple, auditory meatus, shoulder, hip, knee, ankle, heel, toe, and 2 sternum markers placed on a foam piece strapped to the subject's chest. The videotaped movements were automatically digitized (PEAK5 2-D) and the data smoothed using a Butterworth filter. Relative angular ROMs of the head (temple, auditory meatus, shoulder); neck (auditory meatus, shoulder, hip); trunk (near sternum, shoulder, hip); hip (shoulder, hip, knee); sternum/head (sternum near and sternum far with temple and auditory meatus); sternum/trunk (sternum near and sternum far with shoulder and hip); and a sum of 4 angles (head, neck, trunk, hip) were calculated. Sex by equipment repeated measures analyses of variance (ANOVAs) were calculated on the angles of the 5 exercises. When no main effect for sex was found, the data were collapsed across sex and a one-way ANOVA with repeated measures was calculated on the resulting data. Post hoc analyses of pairwise differences were calculated using Tukey's honestly significant difference statistic. Results showed that crunches performed with the abdominal devices resulted in less ROM in all angles measured when compared with a traditional crunch. The

  1. [Dirofilaria in the abdominal cavity].

    PubMed

    Révész, Erzsébet; Markovics, Gabriella; Darabos, Zoltán; Tóth, Ildikó; Fok, Eva

    2008-10-01

    Number of cases of filariasis have been recently reported in the Hungarian medical literature, most of them caused by Dirofilaria repens . Dirofilaria repens is a mosquito-transmitted filarioid worm in the subcutaneous tissue of dogs and cats. Human infection manifests as either subcutaneous nodules or lung parenchymal disease, which may even be asymptomatic. The authors report a human Dirofilaria repens infection of the abdominal cavity in a 61-year-old man,who underwent laparotomy for acute abdomen. Intraoperatively, local peritonitis was detected caused by a white nemathhelminth, measured 8 cm in size. Histocytology confirmed that the infection was caused by Dirofilaria repens.

  2. Technical aspects of abdominal stomas.

    PubMed

    Link, Brian A; Kropp, Bradley; Frimberger, Dominic

    2007-01-01

    Continent urinary diversion has gained increasing popularity in the pediatric population during the last few decades. In adults, continent diversions are usually needed to replace a bladder after cystectomy for invasive carcinoma. Subsequently, the creation of functional and cosmetically hidden urinary and cecal abdominal stomas has become an integral part of many urinary reconstructive procedures. These techniques, originally developed for pediatric urinary reconstruction have gained increasing popularity for adult patients in need of a continence procedure. In the current manuscript, we review the technical aspects of site selection, mucocutaneous anastomosis, cosmetic appearance, and management of associated complications.

  3. Abdominal Compartment Syndrome After Hip Arthroscopy

    DTIC Science & Technology

    2010-01-01

    K. Intra- abdominal compartment syndrome as a complication of ruptured abdomi- nal aortic aneurysm repair. Am Surg 1989;55:396-402. 6. Sugrue M...00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Abdominal Compartment Syndrome After Hip Arthroscopy 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Author’s personal copy Case Report Abdominal Compartment Syndrome After

  4. Relationship between atherosclerosis and knee osteoarthritis as graded by radiography and ultrasonography in females

    PubMed Central

    Ekim, Ayşe Aydemir; İnal, Esra Erkol; Kaya, Dilek Serin; Yılmazer, Şebnem; Kuzgun, Selen; Mumcu, Gamze; Yurdasiper, Alper; Musmul, Ahmet

    2016-01-01

    [Purpose] The aim of this study was to assess the relationship between atherosclerosis and knee osteoarthritis grade in women as assessed by both ultrasonography and radiography. [Subjects and Methods] Seventy women diagnosed with knee osteoarthritis were classified into two groups according to cartilage grading/radiographic grading. Patients with Kellgren-Lawrence grades 1 and 2 were included in group 1, while those with Kellgren-Lawrence grades 3 and 4 were included in group 2. Patients with cartilage grades 1–3 were included in group 1, while those with cartilage grades 4–6 were included in group 2. Patients were clinically assessed using a visual analog scale and the Western Ontario and McMaster Universities Arthritis Index. Radiographic osteoarthritis grade was scored using the Kellgren and Lawrence grading system. Using ultrasonography, symptomatic knees were graded and evaluated for distal femoral cartilage thickness. Carotid intima-media thickness and serum lipid levels were measured to assess atherosclerosis. [Results] Carotid intima-media thickness measurements were higher in group 2 than in group 1 as determined by the Kellgren-Lawrence and cartilage grading systems. Carotid intima-media thickness measurements were positively correlated with both the ultrasonographic cartilage grade and Kellgren-Lawrence. [Conclusion] The results of this study suggest that osteoarthritis as assessed by ultrasonography was successful and comparable to assessment with radiography. We showed a correlation between atherosclerosis and ultrasonographic knee osteoarthritis grade. PMID:27942107

  5. Non-invasive differentiation of kidney stone types using X-ray dark-field radiography.

    PubMed

    Scherer, Kai; Braig, Eva; Willer, Konstantin; Willner, Marian; Fingerle, Alexander A; Chabior, Michael; Herzen, Julia; Eiber, Matthias; Haller, Bernhard; Straub, Michael; Schneider, Heike; Rummeny, Ernst J; Noël, Peter B; Pfeiffer, Franz

    2015-04-15

    Treatment of renal calculi is highly dependent on the chemical composition of the stone in question, which is difficult to determine using standard imaging techniques. The objective of this study is to evaluate the potential of scatter-sensitive X-ray dark-field radiography to differentiate between the most common types of kidney stones in clinical practice. Here, we examine the absorption-to-scattering ratio of 118 extracted kidney stones with a laboratory Talbot-Lau Interferometer. Depending on their chemical composition, microscopic growth structure and morphology the various types of kidney stones show strongly varying, partially opposite contrasts in absorption and dark-field imaging. By assessing the microscopic calculi morphology with high resolution micro-computed tomography measurements, we illustrate the dependence of dark-field signal strength on the respective stone type. Finally, we utilize X-ray dark-field radiography as a non-invasive, highly sensitive (100%) and specific (97%) tool for the differentiation of calcium oxalate, uric acid and mixed types of stones, while additionally improving the detectability of radio-lucent calculi. We prove clinical feasibility of the here proposed method by accurately classifying renal stones, embedded within a fresh pig kidney, using dose-compatible measurements and a quick and simple visual inspection.

  6. Observing the setting and hardening of cementitious materials by X-ray dark-field radiography

    SciTech Connect

    Prade, F.; Chabior, M.; Malm, F.; Grosse, C.U.; Pfeiffer, F.

    2015-08-15

    Novel X-ray imaging methods expand conventional attenuation-based X-ray radiography by the phase- and the dark-field contrasts. While weakly absorbing structures in the specimen can be better visualized in phase contrast, the dark-field contrast provides information about morphological sub-pixel microstructures. Here we report an application of dark-field X-ray radiography for imaging the time-resolved setting process in fresh cement. Our results demonstrate that the microstructural changes within the cement result in a decreasing dark-field signal. We quantify this imaging signal with a time-dependent dark-field scatter coefficient and show its good correlation with the compressional wave velocity. We further present images based on a pixel-wise analysis of the scattering signal and a corresponding logistic fit. These images emphasize the benefit of dark-field imaging of cementitious materials as it provides two dimensional spatial information on the processes within the sample while other established testing techniques only provide information on the bulk average.

  7. Computed radiography as a gamma ray detector—dose response and applications

    NASA Astrophysics Data System (ADS)

    O'Keeffe, D. S.; McLeod, R. W.

    2004-08-01

    Computed radiography (CR) can be used for imaging the spatial distribution of photon emissions from radionuclides. Its wide dynamic range and good response to medium energy gamma rays reduces the need for long exposure times. Measurements of small doses can be performed without having to pre-sensitize the computed radiography plates via an x-ray exposure, as required with screen-film systems. Cassette-based Agfa MD30 and Kodak GP25 CR plates were used in applications involving the detection of gamma ray emissions from technetium-99m and iodine-131. Cassette entrance doses as small as 1 µGy (140 keV gamma rays) produce noisy images, but the images are suitable for applications such as the detection of breaks in radiation protection barriers. A consequence of the gamma ray sensitivity of CR plates is the possibility that some nuclear medicine patients may fog their x-rays if the x-ray is taken soon after their radiopharmaceutical injection. The investigation showed that such fogging is likely to be diffuse.

  8. Material Discrimination for Treaty Verification with Multi-energy, X-ray Radiography

    SciTech Connect

    Gilbert, Andrew J.; McDonald, Benjamin S.; Robinson, Sean M.; White, Timothy A.; Jarman, Kenneth D.; Deinert, Mark

    2013-06-10

    As nuclear warhead stockpiles are reduced under current and future arms treaties, accuracy in accountancy of material stockpiles becomes increasingly important. Image-based active interrogation offers advantages to spectroscopic detection in its ability to measure the location and extent of a material, or materials, of interest from a declaration. However, the detail that imaging provides is often viewed as too intrusive due to its potential to disseminate sensitive information. In this work, we present a method for reducing multi-energy, x-ray radiography data to a few important attributes, based on declarations from behind an information barrier, which can then be used to confirm or deny a declaration. We build on previous work by improving the physics modeling; considering currently attainable, multiple-endpoint x-ray systems; and posing the problem as a nonlinear, inverse problem. Regularization is added to the problem, which smooths the solution and stabilizes an otherwise unstable solution. Here we show the ability to discriminate high-atomic–number materials from others with simulated single-view multiple-endpoint radiography data and present results from initial bench-top measurements.

  9. Effects of dose reduction on the detectability of standardized radiolucent lesions in digital panoramic radiography.

    PubMed

    Dula, K; Sanderink, G; van der Stelt, P F; Mini, R; Buser, D

    1998-08-01

    Dose reduction in digital panoramic radiography was studied. Intentional underexposure was performed with the Orthophos DS while six different human mandibles were radiographed. Exposure settings were 69 kV/15 mA (standard), 64 kV/16 mA, and 60 kV/16 mA. Standardized spherical defects, each either 1 or 1.25 mm in diameter, were simulated in 288 of 432 images, and seven observers decided whether defects were present or not. Areas under the receiver operating characteristics curves were calculated. They showed no significant differences in the detectability of the 1-mm defect at 69, 64, or 60 kV. For the 1.25-mm defect, no difference was found between the 69 and 60 kV images, but a statistically significant different detectability was found for 64 kV images in comparison with both 69 and 60 kV images. A dose reduction of up to 43% was ascertained with a Pedo-RT-Humanoid phantom when panoramic radiography was performed at 60 kV/16 mA. The conclusion is that with the Orthophos DS, it seems possible to reduce the dose rate of x-rays without loss of diagnostic quality in the case of radiolucent changes.

  10. Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

    PubMed Central

    Geha, Hassem; Sankar, Vidya; Teixeira, Fabricio B.; McMahan, Clyde Alex; Noujeim, Marcel

    2015-01-01

    Purpose The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Materials and Methods Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. Results A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. Conclusion CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption. PMID:26389057

  11. [Diagnostic imaging and acute abdominal pain].

    PubMed

    Liljekvist, Mads Svane; Pommergaard, Hans-Christian; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-19

    Acute abdominal pain is a common clinical condition. Clinical signs and symptoms can be difficult to interpret, and diagnostic imaging may help to identify intra-abdominal disease. Conventional X-ray, ultrasound (US) and computed tomography (CT) of the abdomen vary in usability between common surgical causes of acute abdominal pain. Overall, conventional X-ray cannot confidently diagnose or rule out disease. US and CT are equally trustworthy for most diseases. US with subsequent CT may enhance diagnostic precision. Magnetic resonance seems promising for future use in acute abdominal imaging.

  12. Empyema following intra-abdominal sepsis.

    PubMed

    Ballantyne, K C; Sethia, B; Reece, I J; Davidson, K G

    1984-09-01

    Over the past 9 years, ten patients have presented to the Thoracic Unit, Glasgow Royal Infirmary, with 12 empyemas secondary to intra-abdominal sepsis. In eight patients, the presenting signs and symptoms were wrongly attributed to primary intra-thoracic pathology. All were subsequently found to have intra-abdominal sepsis. The presence of empyema after recent abdominal surgery or abdominal pain strongly suggests a diagnosis of ipsilateral subphrenic abscess. Adequate surgical drainage is essential. In our experience, limited thoracotomy with subdiaphragmatic extension offers the best access to both pleural and subphrenic spaces and provides the greatest chance of eradicating infection on both sides of the diaphragm.

  13. Distribution of root exudates and mucilage in the rhizosphere: combining 14C imaging with neutron radiography

    NASA Astrophysics Data System (ADS)

    Holz, Maire; Carminati, Andrea; Kuzyakov, Yakov

    2015-04-01

    Water and nutrients will be the major factors limiting food production in future. Plant roots employ various mechanisms to increase the access to limited soil resources. Low molecular weight organic substances released by roots into the rhizosphere increase nutrient availability by interactions with microorganisms, while mucilage improves water availability under low moisture conditions. Though composition and quality of these substances have intensively been investigated, studies on the spatial distribution and quantification of exudates in soil are scarce. Our aim was to quantify and visualize root exudates and mucilage distribution around growing roots using neutron radiography and 14C imaging depending on drought stress. Plants were grown in rhizotrons well suited for neutron radiography and 14C imaging. Plants were exposed to various soil water contents experiencing different levels of drought stress. The water content in the rhizosphere was imaged during several drying/wetting cycles by neutron radiography. The radiographs taken a few hours after irrigation showed a wet region around the root tips showing the allocation and distribution of mucilage. The increased water content in the rhizosphere of the young root segments was related to mucilage concentrations by parameterization described in Kroener et al. (2014). In parallel 14C imaging of root after 14CO2 labeling of shoots (Pausch and Kuzyakov 2011) showed distribution of rhizodeposits including mucilage. Three days after setting the water content, plants were labeled in 14CO2 atmosphere. Two days later 14C distribution in soil was imaged by placing a phosphor-imaging plate on the rhizobox. To quantify rhizodeposition, 14C activity on the image was related to the absolute 14C activity in the soil and root after destructive sampling. By comparing the amounts of mucilage (neutron radiography) with the amount of total root derived C (14C imaging), we were able to differentiate between mucilage and root

  14. Image quality of digital radiography using flat detector technology

    NASA Astrophysics Data System (ADS)

    Ducourant, Thierry; Couder, David; Wirth, Thibaut; Trochet, J. C.; Bastiaens, Raoul J. M.; Bruijns, Tom J. C.; Luijendijk, Hans A.; Sandkamp, Bernhard; Davies, Andrew G.; Didier, Dominique; Gonzalez, Agustin; Terraz, Sylvain; Ruefenacht, Daniel

    2003-06-01

    One of the most demanding applications in dynamic X-Ray imaging is Digital Subtraction Angiography (DSA). As opposed to other applications such as Radiography or Fluoroscopy, there has been so far limited attempts to introduce DSA with flat detector (FD) technology: Up to now, only part of the very demanding requirements could be taken into account. In order to enable an introduction of FD technology also in this area, a complete understanding of all physical phenomena related to the use of this technology in DSA is necessary. This knowledge can be used for detector design and performance optimization. Areas of research include fast switching between several detector operating modes (e.g. switching between fluoroscopy and high dose exposure modes and vice versa) and non stability during the DSA run e.g. due to differences in gain between subsequent images. Furthermore, effects of local and global X-Ray overexposure (due to direct radiation), which can cause temporal artifacts such as ghosting, may have a negative impact on the image quality. Pixel shift operations and image subtraction enhance the visibility of any artifact. The use of a refresh light plays an important role in the optimization process. Both an 18x18 cm2 as well as a large area 30x40 cm2 flat panel detector are used for studying the various phenomena. Technical measurements were obtained using complex imaging sequences representing the most demanding application conditions. Studies on subtraction test objects were performed and vascular applications have been carried out in order to confirm earlier findings. The basis for comparison of DSA is, still, the existing and mature IITV technology. The results of this investigation show that the latest generation of dynamic flat detectors is capable of handling this kind of demanding application. Not only the risk areas and their solutions and points of attention will be addressed, but also the benefits of present FD technology with respect to state

  15. Mechanical ventilation in abdominal surgery.

    PubMed

    Futier, E; Godet, T; Millot, A; Constantin, J-M; Jaber, S

    2014-01-01

    One of the key challenges in perioperative care is to reduce postoperative morbidity and mortality. Patients who develop postoperative morbidity but survive to leave hospital have often reduced functional independence and long-term survival. Mechanical ventilation provides a specific example that may help us to shift thinking from treatment to prevention of postoperative complications. Mechanical ventilation in patients undergoing surgery has long been considered only as a modality to ensure gas exchange while allowing maintenance of anesthesia with delivery of inhaled anesthetics. Evidence is accumulating, however, suggesting an association between intraoperative mechanical ventilation strategy and postoperative pulmonary function and clinical outcome in patients undergoing abdominal surgery. Non-protective ventilator settings, especially high tidal volume (VT) (>10-12mL/kg) and the use of very low level of positive end-expiratory pressure (PEEP) (PEEP<5cmH2O) or no PEEP, may cause alveolar overdistension and repetitive tidal recruitment leading to ventilator-associated lung injury in patients with healthy lungs. Stimulated by previous findings in patients with acute respiratory distress syndrome, the use of lower tidal volume ventilation is becoming increasingly more common in the operating room. However, lowering tidal volume, though important, is only part of the overall multifaceted approach of lung protective mechanical ventilation. In this review, we aimed at providing the most recent and relevant clinical evidence regarding the use of mechanical ventilation in patients undergoing abdominal surgery.

  16. a Single-Exposure Dual-Energy Computed Radiography Technique for Improved Nodule Detection and Classification in Chest Imaging

    NASA Astrophysics Data System (ADS)

    Zink, Frank Edward

    The detection and classification of pulmonary nodules is of great interest in chest radiography. Nodules are often indicative of primary cancer, and their detection is particularly important in asymptomatic patients. The ability to classify nodules as calcified or non-calcified is important because calcification is a positive indicator that the nodule is benign. Dual-energy methods offer the potential to improve both the detection and classification of nodules by allowing the formation of material-selective images. Tissue-selective images can improve detection by virtue of the elimination of obscuring rib structure. Bone -selective images are essentially calcium images, allowing classification of the nodule. A dual-energy technique is introduced which uses a computed radiography system to acquire dual-energy chest radiographs in a single-exposure. All aspects of the dual-energy technique are described, with particular emphasis on scatter-correction, beam-hardening correction, and noise-reduction algorithms. The adaptive noise-reduction algorithm employed improves material-selective signal-to-noise ratio by up to a factor of seven with minimal sacrifice in selectivity. A clinical comparison study is described, undertaken to compare the dual-energy technique to conventional chest radiography for the tasks of nodule detection and classification. Observer performance data were collected using the Free Response Observer Characteristic (FROC) method and the bi-normal Alternative FROC (AFROC) performance model. Results of the comparison study, analyzed using two common multiple observer statistical models, showed that the dual-energy technique was superior to conventional chest radiography for detection of nodules at a statistically significant level (p < .05). Discussion of the comparison study emphasizes the unique combination of data collection and analysis techniques employed, as well as the limitations of comparison techniques in the larger context of technology

  17. X-radiography of trace fossils in limestones and dolostones from the Jurassic Smackover Formation, south Alabama

    SciTech Connect

    Esposito, R.A.; Castleman, S.P.; King, D.T. Jr.

    1985-01-01

    X-radiography has been useful in studying biogenic sedimentary structures in unconsolidated sediments but the technique has not been applied often to the study of hard carbonate rock. The authors have applied x-radiography to the study of the lower part of the Smackover to enhance the complete petrologic description of the rock. The lower Smackover has many dense micrite intervals and intervals of monotonous, thin graded beds. Parts of the lower Smackover is also dolomitized. None of the above rocks contains significant amount of skeletal debris and trace fossils are not generally obvious in an etched slab of core. In limestone, they have detected well-preserved trace fossils by x-radiography, however. The dolostones show no traces using our method. In limestones, the traces are marked by minute amounts of finely divided iron sulfides. This causes a slight density difference resulting in greater x-ray absorption. They recognize two main trace-fossil types: a Thalassinoides best seen in slabs cut parallel to bedding and a Zoophycos best seen in slabs cut perpendicular to bedding. The technique requires a slab cut 8 mm thick with parallel flat surfaces and a medical x-ray unit using accelerating voltages of 66 kV and 10 mas. Traces are most successfully imaged on industrial-quality films.

  18. Abdominal Necrotising Fascitis Mimicking Peritonitis in a Gatka Playing Indian Male: A Case Report

    PubMed Central

    Singh, Devinder Pal

    2016-01-01

    The present case report is of abdominal Necrotising Fascitis in a young Gatka player. The patient was clinically diagnosed to have peritonitis with plan for laparotomy but since ultrasound abdomen showed no free intra-abdominal fluid and any other pathology a Contrast Enhanced Computed tomography (CECT) abdomen was done. CECT showed fluid collections in rectus sheath and superficial fascia. Patient was thus, diagnosed as having abdominal myofascitis and treated accordingly. A review of literature showed that such a clinical presentation of this disease is quite rare and can lead to unnecessary laparotomy and delay in diagnosis leading to morbidity. PMID:28050443

  19. Abdominal Pain, the Adolescent and Altered Brain Structure and Function

    PubMed Central

    Becerra, Lino; Heinz, Nicole; Ludwick, Allison; Rasooly, Tali; Wu, Rina; Johnson, Adriana; Schechter, Neil L.; Borsook, David; Nurko, Samuel

    2016-01-01

    Irritable bowel syndrome (IBS) is a functional gastrointestinal (GI) disorder of unknown etiology. Although relatively common in children, how this condition affects brain structure and function in a pediatric population remains unclear. Here, we investigate brain changes in adolescents with IBS and healthy controls. Imaging was performed with a Siemens 3 Tesla Trio Tim MRI scanner equipped with a 32-channel head coil. A high-resolution T1-weighted anatomical scan was acquired followed by a T2-weighted functional scan. We used a surface-based morphometric approach along with a seed-based resting-state functional connectivity (RS-FC) analysis to determine if groups differed in cortical thickness and whether areas showing structural differences also showed abnormal RS-FC patterns. Patients completed the Abdominal Pain Index and the GI Module of the Pediatric Quality of Life Inventory to assess abdominal pain severity and impact of GI symptoms on health-related quality of life (HRQOL). Disease duration and pain intensity were also assessed. Pediatric IBS patients, relative to controls, showed cortical thickening in the posterior cingulate (PCC), whereas cortical thinning in posterior parietal and prefrontal areas were found, including the dorsolateral prefrontal cortex (DLPFC). In patients, abdominal pain severity was related to cortical thickening in the intra-abdominal area of the primary somatosensory cortex (SI), whereas HRQOL was associated with insular cortical thinning. Disease severity measures correlated with cortical thickness in bilateral DLPFC and orbitofrontal cortex. Patients also showed reduced anti-correlations between PCC and DLPFC compared to controls, a finding that may reflect aberrant connectivity between default mode and cognitive control networks. We are the first to demonstrate concomitant structural and functional brain changes associated with abdominal pain severity, HRQOL related to GI-specific symptoms, and disease-specific measures in

  20. Abdominal wall abscess: more than meets the eye.

    PubMed

    Gandhi, Jamish; Gandhi, Natasha

    2010-01-01

    An 83-year-old, mildly demented rest home resident presented to the emergency department with a 2 day history of a right sided abdominal wall mass. He had a mechanical fall 2 days previously and landed on his right side and had attributed the mass to this. He had no symptoms apart from feeling bloated and not being able to pass wind for a day. He had passed a normal bowel motion the day before presentation. On abdominal examination there was an 11 × 4 cm mass in the right lower quadrant. It was firm in consistency, non-fluctuant and non-tender to touch. There was mild erythema over the area but no skin breaks. Chest radiograph was unremarkable. The abdominal film showed dilated small bowel and no large bowel could be seen. A computed tomography (CT) scan showed a thick walled gallbladder with multiple calculi and air present. There was also an extensive air and fluid collection in the layers of the abdominal wall and subcutaneous fat which arose from a perforation of the gallbladder. The patient was not a surgical candidate due to multiple comorbidities. The patient was treated with antibiotics and underwent a CT guided percutaneous cholecystostomy. Despite the radiological intervention and antibiotics the patient progressively deteriorated and died peacefully 5 days after admission.

  1. Genetic Architecture of Abdominal Pigmentation in Drosophila melanogaster

    PubMed Central

    Dembeck, Lauren M.; Huang, Wen; Magwire, Michael M.; Lawrence, Faye; Lyman, Richard F.; Mackay, Trudy F. C.

    2015-01-01

    Pigmentation varies within and between species and is often adaptive. The amount of pigmentation on the abdomen of Drosophila melanogaster is a relatively simple morphological trait, which serves as a model for mapping the genetic basis of variation in complex phenotypes. Here, we assessed natural variation in female abdominal pigmentation in 175 sequenced inbred lines of the Drosophila melanogaster Genetic Reference Panel, derived from the Raleigh, NC population. We quantified the proportion of melanization on the two most posterior abdominal segments, tergites 5 and 6 (T5, T6). We found significant genetic variation in the proportion of melanization and high broad-sense heritabilities for each tergite. Genome-wide association studies identified over 150 DNA variants associated with the proportion of melanization on T5 (84), T6 (34), and the difference between T5 and T6 (35). Several of the top variants associated with variation in pigmentation are in tan, ebony, and bric-a-brac1, genes known to affect D. melanogaster abdominal pigmentation. Mutational analyses and targeted RNAi-knockdown showed that 17 out of 28 (61%) novel candidate genes implicated by the genome-wide association study affected abdominal pigmentation. Several of these genes are involved in developmental and regulatory pathways, chitin production, cuticle structure, and vesicle formation and transport. These findings show that genetic variation may affect multiple steps in pathways involved in tergite development and melanization. Variation in these novel candidates may serve as targets for adaptive evolution and sexual selection in D. melanogaster. PMID:25933381

  2. Genetic Architecture of Abdominal Pigmentation in Drosophila melanogaster.

    PubMed

    Dembeck, Lauren M; Huang, Wen; Magwire, Michael M; Lawrence, Faye; Lyman, Richard F; Mackay, Trudy F C

    2015-05-01

    Pigmentation varies within and between species and is often adaptive. The amount of pigmentation on the abdomen of Drosophila melanogaster is a relatively simple morphological trait, which serves as a model for mapping the genetic basis of variation in complex phenotypes. Here, we assessed natural variation in female abdominal pigmentation in 175 sequenced inbred lines of the Drosophila melanogaster Genetic Reference Panel, derived from the Raleigh, NC population. We quantified the proportion of melanization on the two most posterior abdominal segments, tergites 5 and 6 (T5, T6). We found significant genetic variation in the proportion of melanization and high broad-sense heritabilities for each tergite. Genome-wide association studies identified over 150 DNA variants associated with the proportion of melanization on T5 (84), T6 (34), and the difference between T5 and T6 (35). Several of the top variants associated with variation in pigmentation are in tan, ebony, and bric-a-brac1, genes known to affect D. melanogaster abdominal pigmentation. Mutational analyses and targeted RNAi-knockdown showed that 17 out of 28 (61%) novel candidate genes implicated by the genome-wide association study affected abdominal pigmentation. Several of these genes are involved in developmental and regulatory pathways, chitin production, cuticle structure, and vesicle formation and transport. These findings show that genetic variation may affect multiple steps in pathways involved in tergite development and melanization. Variation in these novel candidates may serve as targets for adaptive evolution and sexual selection in D. melanogaster.

  3. Fiber architecture of canine abdominal muscles.

    PubMed

    Boriek, Aladin M; Ortize, Jaime; Zhu, Deshen

    2002-02-01

    During respiration, abdominal muscles experience loads, not only in the muscle-fiber direction but also transverse to the fibers. We wondered whether the abdominal muscles exhibit a fiber architecture that is similar to the diaphragm muscle, and, therefore, we chose two adjacent muscles: the internal oblique (IO), with about the same muscle length as the diaphragm, and the transverse abdominis (TA), which is twice as long as the diaphragm. First, we used acetylcholinesterase staining to examine the distribution of neuromuscular junctions on both surfaces of the TA and IO muscles in six dogs. A maximum of four irregular bands of neuromuscular junctions crossed the IO, and as many as six bands crossed the TA, which is consistent with a discontinuous fiber architecture. In six additional dogs, we examined fiber architecture of these muscles by microdissecting 103 fascicles from the IO and 139 from the TA. Each fascicle contained between 20 and 30 muscle fibers. The mean length of nonspanning fibers (NSF) ranged from 2.8 +/- 0.3 cm in the IO to 4.3 +/- 0.5 cm in the TA, and the mean length of spanning fibers ranged from 4.3 +/- 0.5 cm in the IO to 7.6 +/- 1.4 cm in the TA. NSF accounted for 89.6 +/- 1.5% of all fibers dissected from the IO and 99.1 +/- 0.2% of all fibers dissected from the TA. The percentage of NSF with both ends tapered was 6.2 +/- 1.0 and 41.0 +/- 2.3% for IO and TA, respectively. These data show that fiber architecture in either IO or TA is discontinuous, with much more short-tapered fibers in the TA than in the IO. When abdominal muscles are submaximally activated, as during both normal expiration and maximal expiratory efforts, muscle force could be transmitted to the cell membrane and to the extracellular intramuscular connective tissue by shear linkage, presumably via structural transmembrane proteins.

  4. Exposure reduction of 96% in intraoral radiography

    SciTech Connect

    Kircos, L.T.; Vandre, R.H.; Lorton, L.

    1986-11-01

    This study compared the diagnostic quality of E-speed film, xeroradiographic cassettes, and a screen-film imaging system used in medical radiology. The surfaces of defects simulating caries were scored for the presence and depth of the defects under ideal viewing conditions by independent observers. Receiver Operator Characteristics analysis of the data showed no significant differences regarding diagnostic potential among the three systems. The true-positive fraction was 1.00 for all systems and all operators, and the false-positive fraction was .011, .011, and .007, respectively. An exposure of 5.5 mR was used to produce images with the screen-film combination, and 150 mR was used for standard dental systems. This study showed that an exposure reduction of 96% is possible while maintaining high-quality radiographs for the diagnosis of caries.

  5. Abdominal aortic aneurysms in women

    PubMed Central

    Lo, Ruby C.; Schermerhorn, Marc L.

    2015-01-01

    Abdominal aortic aneurysm (AAA) has long been recognized as a condition predominantly afflicting males, with sex-associated differences described for almost every aspect of the disease from pathophysiology and epidemiology to morbidity and mortality. Women are generally spared from AAA formation by the immunomodulating effects of estrogen but once they develop, the natural history of AAAs in women appears to be more aggressive, with more rapid expansion, a higher tendency to rupture at smaller diameters, and higher mortality following rupture. However, simply repairing AAA at smaller diameters in women is a debatable solution, as even elective endovascular AAA repair (EVAR) is fraught with higher morbidity and mortality in women compared to men. The goal of this review is to summarize what is currently known about the effect of gender on AAA presentation, treatment, and outcomes. Additionally, we aim to review current controversies over screening recommendations and threshold for repair in women. PMID:26747679

  6. [A case report of Ewing's sarcoma with a peripheral primitive neuroectodermal tumor (ES/pPNET) in the abdominal cavity].

    PubMed

    Takahashi, Hiroki; Chida, Nobuyuki; Kimura, Kenji; Yamao, Yoko; Shiotuka, Kaori; Ritsuno, Hideaki; Awabuchi, Satoshi; Akoshima, Hiromichi; Sugimura, Mikako; Noguchi, Kenji; Tanabe, Nobukazu; Iwabuchi, Masahiro; Mano, Yutaka; Tadokoro, Keiichi; Suzuki, Hiroyoshi

    2009-10-01

    In this report, we present a rare case of Ewing's sarcoma with a peripheral primitive neuroectodermal tumor (ES/pPNET) arising from the abdominal cavity in a 20-year-old woman. The patient complained of upper abdominal pain. Radiological imaging showed a 15-cm mass penetrating to the proxymal jejunum in the upper abdominal cavity and peritoneal disseminations. Immunohistochemical studies revealed that the tumor was ES/pPNET. Although the patient underwent radiation therapy, she died of the disease two months after diagnosis. ES/pPNET in the abdominal cavity is extremely rare and our case showed aggressive behavior and an unfortunate outcome.

  7. Pulmonary complications of abdominal wall defects.

    PubMed

    Panitch, Howard B

    2015-01-01

    The abdominal wall is an integral component of the chest wall. Defects in the ventral abdominal wall alter respiratory mechanics and can impair diaphragm function. Congenital abdominal wall defects also are associated with abnormalities in lung growth and development that lead to pulmonary hypoplasia, pulmonary hypertension, and alterations in thoracic cage formation. Although infants with ventral abdominal wall defects can experience life-threatening pulmonary complications, older children typically experience a more benign respiratory course. Studies of lung and chest wall function in older children and adolescents with congenital abdominal wall defects are few; such investigations could provide strategies for improved respiratory performance, avoidance of respiratory morbidity, and enhanced exercise ability for these children.

  8. A rare case of abdominal infection: Emphysematous pyelonephritis without diabetes

    PubMed Central

    Ünlüer, Erden Erol; Şahı̇n, Yusuf; Oyar, Orhan; Tan, Gözde Canan; Karagöz, Arı̇f; Turan, Celaleddı̇n

    2016-01-01

    Emphysematous pyelonephritis (EP) is a rare form of necrotizing pyelonephritis. It is a life-threatening condition that usually affects patients with diabetes, and a small percentage may be due to urinary tract obstruction. Here, we present the case of an EP caused by urinary tract obstruction without diabetes. A 45-year-old woman presented to the emergency department with fever, chills, and abdominal pain. There was no significant past history. Physical examination depicted bilateral lower abdominal and right flank knocking tenderness. Laboratory exams revealed leukocytosis, neutrophilia, a high C-reactive protein level, and pyuria. Abdominal computerized tomography (CT) showed diffuse gas in the right renal collecting system and dilatation of the right renal pelvis compared to the right side, in addition to multiple millimetric stones located in the right kidney and right ureter. After emergent placement of a percutaneous nephrostomy, she was admitted. Control abdominal CT without contrast revealed the absence of gas, hydronephrosis of the right renal pelvis, and the presence of nephrolithiasis. The patient was discharged 10 days of post-procedure with instructions for follow-up. Emergency physicians need to remain alert about this life-threatening disease and the typical CT findings of this disease to make a timely diagnosis and navigate management. PMID:28250980

  9. An uncommon cause of abdominal pain: Mesenteric cyst

    PubMed Central

    Ünlüer, Erden Erol; Ünlüer, Seran; Şahı̇n, Yusuf; Kamer, Kemal Erdı̇nç; Karagöz, Arı̇f; Tan, Gözde Canan

    2016-01-01

    Mesenteric cysts are benign cystic lesions. Here, we present the case of a patient with abdominal pain, which was diagnosed as mesenteric cyst. A 28-year-old male patient was admitted to the emergency department (ED) with abdominal pain and distention. Abdominal palpation revealed a smooth-surfaced mass palpable in the left upper quadrant. Ultrasonography depicted a hypoechoic heterogeneous mass-like structure with a size of 15 × 12 cm. Computerized tomography (CT) showed a well-defined cystic structure with a size of 12 × 12.5 cm near to the duodenum and pancreas. The patient was admitted, and the cystic structure was drained with a percutaneous drainage catheter; then, sclerotherapy was performed using ethyl alcohol with the aid of ultrasonography. The material was sent to the pathology lab and revealed negative results for malignant cell and mucin. The patient underwent a control CT with contrast, which revealed the catheter at the site of the operation and no cystic lesion after procedure. He was discharged 1 week after the procedure. Mesenteric cysts are extremely rare benign lesions of the abdomen, and emergency physicians must consider this disease in the differential diagnosis of abdominal pain. The percutaneous drainage technique performed on our patient is a safe technique for the treatment of selected patients. PMID:28250978

  10. [Living with a chronic abdominal wound--the patients' perspective].

    PubMed

    Rüeger-Schaad, Elisabeth; Panfil, Eva-Maria; Viehl, Carsten T; Spirig, Rebecca

    2008-08-01

    Chronic abdominal wounds lead to prolonged hospital stays. However, no data exist that describe the experience of persons living with a chronic abdominal wound. The aim of this qualitative study was to explore the experience of persons living with chronic abdominal wounds and elicit their expectations in health professionals. Narrative interviews were conducted with five women and four men. Using content analysis techniques, five categories with one to four subcategories emerged from the data. "Returning to everyday life without a wound" represents the main goal of the participants and is driven by their hope to achieve this outcome. "Everyday life with the wound" illustrates the reality of participants' lives, which is affected by suffering. "The patients' work" demonstrates the component that patients contribute to managing their wound. "The work of primary support persons" shows the importance of the work of people close to the patient. "The work of professionals" includes the expectations that patients have in their caregivers. Teamwork between professionals, patients and primary support persons seems to be an essential condition for the successful healing of an abdominal wound.

  11. Laparoscopic management of primary abdominal pregnancy: a case report.

    PubMed

    Altay, Mehmet Metin; Dündar, Betül; Erol, Ahmet Okyar; Kurtaran, Volkan; Gelişen, Orhan

    2010-01-01

    This is a case report of a primary abdominal pregnancy managed by laparoscopic intervention. A 22 year old, gravida 1, woman was admitted to our emergency room with vaginal bleeding and pain in lower abdomen. She was 4 weeks pregnant according to her last menstrual period. She had undergone right salpingoophorectomy previously. Pelvic examination revealed cervical motion tenderness, bilateral adnexal tenderness and rebound tenderness. Her vital signs were normal. Beta hCG was 15826 IU/ml and hemoglobin was 10.0 g/dl. Transvaginal sonography showed an endometrium of 3 mm thickness and free fluid in the pelvis. Upon admission to the Early Pregnancy Clinic, abdominal pain became worse and hemoglobin decreased to 8.0 g/dL. Therefore, we performed a laparoscopy which showed that the uterus, left tube and ovary were completely normal with absence of the right ovary and tube. Approximately 500 cc blood was aspirated from the pelvis. Between the right sacrouterine ligament and rectum, there was a bleeding area 2 cm in width which was removed with forceps and sent for frozen pathological examination,which revealed 'placental tissue fragments'. Endometrial sampling was reported to be 'secretory endometrium'. A rapid decrease in the beta HCG post operative titer confirmed the resolution of the pregnancy. Primary abdominal pregnancy is extremely rare. The diagnosis is confirmed according to Studdiford's criteria. In the literature, there only a few cases of abdominal pregnancy in which laparoscopic procedure has been used effectively as treatment. However, laparoscopic procedure is usually successful in treatment of abdominal pregnancy if the gestational age is early enough.

  12. The role of postoperative chest radiography in pediatric tracheotomy.

    PubMed

    Greenberg, J S; Sulek, M; de Jong, A; Friedman, E M

    2001-07-30

    A postoperative chest radiograph has traditionally been obtained after tracheotomies to evaluate for the presence of a pneumothorax and to assess tube position. Several recent studies in adults have questioned the usefulness of routine postoperative chest radiography in uncomplicated cases, but the role of post-operative chest radiography in pediatric patients has not been previously reviewed. We performed this study to examine the clinical utility of post-tracheotomy chest radiography in pediatric patients and determine if this routine practice impacts patient management enough to merit continued usage. A retrospective review was performed of 200 consecutive pediatric patients who underwent tracheotomies by the otolaryngology service in a tertiary care pediatric hospital from January 1994 to June 1999. All patients received postoperative chest radiographs. Five of 200 patients had a new postoperative radiographic finding, with three requiring interventions. Two patients required chest tube placement for pneumothorax, and one patient required tracheostomy tube change for repositioning. Fifty-one patients, including both pneumothoraces, exhibited clinical signs of pneumothorax (decreased breath sounds or oxygen saturation) in the immediate postoperative period. Chest X-ray ruled out a pneumothorax in the remaining 49 patients. The majority of these 51 patients were less than 2 years old (94%, P=0.002) or weighed less than 17 kg (89%, P=0.004). Postoperative chest X-rays yielded clinically relevant information in 168 patients that fell into one or more of four high risk categories: age less than 2, weight less than 17 kg, emergent procedures, or concomitant central line placement. Avoiding chest X-rays in the remaining 32 patients would have resulted in potential savings of $5000, which does not reflect the actuarial cost of a missed complication. Since the majority of our patients (84%) fell into a high-risk category, we feel it would be prudent to continue

  13. Spectroscopic neutron radiography for a cargo scanning system

    NASA Astrophysics Data System (ADS)

    Rahon, Jill; Danagoulian, Areg; MacDonald, Thomas D.; Hartwig, Zachary S.; Lanza, Richard C.

    2016-06-01

    Detection of cross-border smuggling of illicit materials and contraband is a challenge that requires rapid, low-dose, and efficient radiographic technology. The work we describe here is derived from a technique which uses monoenergetic gamma rays from low energy nuclear reactions, such as 11B(d,nγ)12C, to perform radiographic analysis of shipping containers. Transmission ratios of multiple monoenergetic gamma lines resulting from several gamma producing nuclear reactions can be employed to detect materials of high atomic number (Z), the details of which will be described in a separate paper. Inherent in this particular nuclear reaction is the production of fast neutrons which could enable neutron radiography and further characterization of the effective-Z of the cargo, especially within the range of lower Z. Previous research efforts focused on the use of total neutron counts in combination with X-ray radiography to characterize the hydrogenous content of the cargo. We present a technique of performing transmitted neutron spectral analysis to reconstruct the effective Z and potentially the density of the cargo. This is made possible by the large differences in the energy dependence of neutron scattering cross-sections between hydrogenous materials and those of higher Z. These dependencies result in harder transmission spectra for hydrogenous cargoes than those of non-hydrogenous cargoes. Such observed differences can then be used to classify the cargo based on its hydrogenous content. The studies presented in this paper demonstrate that such techniques are feasible and can provide a contribution to cargo security, especially when used in concert with gamma radiography.

  14. BBU design of linear induction accelerator cells for radiography application

    SciTech Connect

    Shang, C.C.; Chen, Y.J.; Gaporaso, G.J.; Houck, T.L.; Molau, N.E.; Focklen, J.; Gregory, S.

    1997-05-06

    There is an ongoing effort to develop accelerating modules for high-current electron accelerators for advanced radiography application. Accelerating modules with low beam-cavity coupling impedances along with gap designs with acceptable field stresses comprise a set of fundamental design criteria. We examine improved cell designs which have been developed for accelerator application in several radiographic operating regimes. We evaluate interaction impedances, analyze the effects of beam structure coupling on beam dynamics (beam break-up instability and corkscrew motion). We also provide estimates of coupling through interesting new high-gradient insulators and evaluate their potential future application in induction cells.

  15. X-ray vector radiography imaging for biomedical applications

    SciTech Connect

    Potdevin, Guillaume; Malecki, Andreas; Biernath, Thomas; Bech, Martin; Pfeiffer, Franz

    2012-07-31

    The non-invasive estimation of fracture risk in osteoporosis remains a challenge in the clinical routine and is mainly based on an assessment of bone density by dual X-ray absorption (DXA) although bone micro-architecture is known to play an important role for bone fragility. Here we report on 'X-ray vector Radiography' measurements able to provide a direct bone microstructure diagnostics on human bone samples, which we compare qualitatively and quantitatively with numerical analysis of high resolution radiographs.

  16. [A scientometric radiography of Revista Médica de Chile].

    PubMed

    Krauskopf, M

    1997-07-01

    In the context of a festschrift to commemorate the 125th anniversary of the Revista Médica de Chile, "radiography" of the journal has been depicted using several scientometric indicators. Among the mainstream journals in the category of Medicine, General & Internal and taking into account the wide editorial coverage and the language of the publication that fulfills the need for the required social appropriation of science that the country requires, the Revista Médica de Chile portrays healthy and quite relevant. Among the articles published between 1981 and 1995, some concerning public health have reached, particularly, an impact which surpasses their mean expected citation rate.

  17. Excretory urography using dual-energy scanned projection radiography

    SciTech Connect

    Soomer, F.G.; Brody, W.R.; Gross, D.; Macovski, A.; Hall, A.; Pelc, N.

    1981-11-01

    Excretory urograms of 10 patients were obtained using a GE 8800 CT scanner with Scout View which had been modified for dual-kVp scanned projection radiography. Using this system, it is possible to combine images obtained simultaneously at 85 and 135 kVp to create subtraction images from which substances of desired mean atomic number have been removed. This permits improved visualization of the genitourinary system on urograms by (a) eliminating obscuring bowel gas shadows and (b) enhancement of both iodinated contrast media and retroperitoneal fat planes.

  18. DIGITAL RADIOGRAPHY OF SPECIAL NUCLEAR MATERIAL TEST PACKAGES

    SciTech Connect

    HOWARD, BOYD

    2006-02-02

    The purpose of this document is to provide a brief introduction to digital radiography (DR), and a description of the DR configuration that was used to radiographically image the Special Nuclear Material (SNM) Test Packages before and after function tests that have been conducted. Also included are (1) Attachment 1, a comprehensive index that describes at which phase of the certification process that digital radiographic images were acquired, (2) digital radiographic images of each of the six packages at various stages of the certification process, and (3) Attachment 2, imaging instructions, that specify the setup procedures and detailed parameters of the DR imaging methodology that were used.

  19. Computers in dental radiography: a scenario for the future

    SciTech Connect

    Webber, R.L.

    1985-09-01

    The recent emergence of cost-effective computing power makes it possible to integrate sophisticated data-sampling and image-interpretation techniques into dental radiography for the first time. A prototype system is being developed to permit clinical information expressed in three dimensions--plus time--to be made visible almost instantly. The associated X-ray dose for a complete three-dimensional survey of a selected dental region is predicted to be less than that required for a single conventional periapical radiograph exposed on D-speed film.

  20. X-ray vector radiography imaging for biomedical applications

    NASA Astrophysics Data System (ADS)

    Potdevin, Guillaume; Malecki, Andreas; Biernath, Thomas; Bech, Martin; Pfeiffer, Franz

    2012-07-01

    The non-invasive estimation of fracture risk in osteoporosis remains a challenge in the clinical routine and is mainly based on an assessment of bone density by dual X-ray absorption (DXA) although bone micro-architecture is known to play an important role for bone fragility. Here we report on 'X-ray vector Radiography' measurements able to provide a direct bone microstructure diagnostics on human bone samples, which we compare qualitatively and quantitatively with numerical analysis of high resolution radiographs.

  1. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements §...

  2. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements §...

  3. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements §...

  4. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements §...

  5. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements §...

  6. 10 CFR 34.20 - Performance requirements for industrial radiography equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Performance requirements for industrial radiography equipment. 34.20 Section 34.20 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND... meet the following minimum criteria: (a)(1) Each radiographic exposure device, source assembly...

  7. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements §...

  8. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements §...

  9. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements §...

  10. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements §...

  11. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements §...

  12. Dual Use Corrosion Inhibitor and Penetrant for Anomaly Detection in Neutron/X Radiography

    NASA Technical Reports Server (NTRS)

    Hall, Phillip B. (Inventor); Novak, Howard L. (Inventor)

    2004-01-01

    A dual purpose corrosion inhibitor and penetrant composition sensitive to radiography interrogation is provided. The corrosion inhibitor mitigates or eliminates corrosion on the surface of a substrate upon which the corrosion inhibitor is applied. In addition, the corrosion inhibitor provides for the attenuation of a signal used during radiography interrogation thereby providing for detection of anomalies on the surface of the substrate.

  13. 75 FR 57080 - In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-17

    ... COMMISSION In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order... which authorizes the possession, use, and operation of the Aerotest Radiography and Research Reactor... Regulations (10 CFR) Section 50.21(c) for research and development purposes. Aerotest is a wholly...

  14. 75 FR 27368 - Aerotest Operations, Inc., Aerotest Radiography and Research Reactor; Notice of Consideration of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ... COMMISSION Aerotest Operations, Inc., Aerotest Radiography and Research Reactor; Notice of Consideration of... INFORMATION CONTACT: Cindy Montgomery, Project Manager, Research and Test Reactors Licensing Branch, Division... Operating License No. R-98 for the Aerotest Radiography and Research Reactor (ARRR), currently held...

  15. 42 CFR 37.51 - Interpreting and classifying chest radiographs-digital radiography systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-digital radiography systems. 37.51 Section 37.51 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH..., and Submission of Chest Radiographs § 37.51 Interpreting and classifying chest radiographs—digital radiography systems. (a) For each chest radiograph obtained at an approved facility using a...

  16. Construction of Abdominal Probabilistic Atlases and Their Value in Segmentation of Normal Organs in Abdominal CT Scans

    NASA Astrophysics Data System (ADS)

    Park, Hyunjin; Hero, Alfred; Bland, Peyton; Kessler, Marc; Seo, Jongbum; Meyer, Charles

    A good abdominal probabilistic atlas can provide important information to guide segmentation and registration applications in the abdomen. Here we build and test probabilistic atlases using 24 abdominal CT scans with available expert manual segmentations. Atlases are built by picking a target and mapping other training scans onto that target and then summing the results into one probabilistic atlas. We improve our previous abdominal atlas by 1) choosing a least biased target as determined by a statistical tool, i.e. multidimensional scaling operating on bending energy, 2) using a better set of control points to model the deformation, and 3) using higher information content CT scans with visible internal liver structures. One atlas is built in the least biased target space and two atlases are built in other target spaces for performance comparisons. The value of an atlas is assessed based on the resulting segmentations; whichever atlas yields the best segmentation performance is considered the better atlas. We consider two segmentation methods of abdominal volumes after registration with the probabilistic atlas: 1) simple segmentation by atlas thresholding and 2) application of a Bayesian maximum a posteriori method. Using jackknifing we measure the atlas-augmented segmentation performance with respect to manual expert segmentation and show that the atlas built in the least biased target space yields better segmentation performance than atlases built in other target spaces.

  17. Implementation of a PACS for radiography training and clinical service in a university setting through a multinational effort

    NASA Astrophysics Data System (ADS)

    Tang, Fuk-hay; Law, Yuen Y.; Zhang, Jianguo; Liu, Hai L.; Chang, Tony; Matsuda, Koyo; Cao, Fei

    2001-08-01

    The Hong Kong Polytechnic University has a Radiography Division under the Development of Optometry and Radiography. The Division trains both diagnostic and therapeutic radiographers with 60 students/year and offers a B.Sc. degree. In addition the Division together with the University Health Service operates a radiography clinic with radiology consultation from radiologists from other hospitals and clinics. This paper describers the implementation of a PACS in the Division for radiography training, and for clinical service.

  18. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system

    PubMed Central

    Wood, T J; Beavis, A W; Saunderson, J R

    2013-01-01

    Objective: The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. Methods: The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson’s correlation coefficient. Results: Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Conclusion: Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. Advances in knowledge: A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography. PMID:23568362

  19. Intestinal injury mechanisms after blunt abdominal impact.

    PubMed

    Cripps, N P; Cooper, G J

    1997-03-01

    Intestinal injury is frequent after non-penetrating abdominal trauma, particularly after modern, high-energy transfer impacts. Under these circumstances, delay in the diagnosis of perforation is a major contributor to morbidity and mortality. This study establishes patterns of intestinal injury after blunt trauma by non-penetrating projectiles and examines relationships between injury distribution and abdominal wall motion. Projectile impacts of variable momentum were produced in 31 anaesthetised pigs to cause abdominal wall motion of varying magnitude and velocity. No small bowel injury was observed at initial impact velocity of less than 40 m/s despite gross abdominal compression. At higher velocity, injury to the small bowel was frequent, irrespective of the degree of abdominal compression (P = 0.00044). Large bowel injury was observed at all impact velocities and at all degrees of abdominal compression. This study confirms the potential for intestinal injury in high velocity, low momentum impacts which do not greatly compress the abdominal cavity and demonstrates apparent differences in injury mechanisms for the small bowel and colon. Familiarity with injury mechanisms may reduce delays in the diagnosis of intestinal perforation in both military and civilian situations.

  20. The prognosis of childhood abdominal migraine

    PubMed Central

    Dignan, F; Abu-Arafeh, I; Russell, G

    2001-01-01

    AIMS—To determine the clinical course of childhood abdominal migraine, seven to 10 years after the diagnosis.
METHODS—A total of 54 children with abdominal migraine were studied; 35 were identified from a population survey carried out on Aberdeen schoolchildren between 1991 and 1993, and 19 from outpatient records of children in the same age group who had attended the Royal Aberdeen Children's Hospital. Controls were 54 children who did not have abdominal pain in childhood, matched for age and sex, obtained from either the population survey or the patient administration system. Main outcome measures were presence or resolution of abdominal migraine and past or present history of headache fulfilling the International Headache Society (IHS) criteria for the diagnosis of migraine.
RESULTS—Abdominal migraine had resolved in 31 cases (61%). Seventy per cent of cases with abdominal migraine were either current (52%) or previous (18%) sufferers from headaches that fulfilled the IHS criteria for migraine, compared to 20% of the controls.
CONCLUSIONS—These results support the concept of abdominal migraine as a migraine prodrome, and suggest that our diagnostic criteria for the condition are robust.

 PMID:11316687

  1. Unified Database for Rejected Image Analysis Across Multiple Vendors in Radiography.

    PubMed

    Little, Kevin J; Reiser, Ingrid; Liu, Lili; Kinsey, Tiffany; Sánchez, Adrian A; Haas, Kateland; Mallory, Florence; Froman, Carmen; Lu, Zheng Feng

    2017-02-01

    Reject rate analysis has been part of radiography departments' quality control since the days of screen-film radiography. In the era of digital radiography, one might expect that reject rate analysis is easily facilitated because of readily available information produced by the modality during the examination procedure. Unfortunately, this is not always the case. The lack of an industry standard and the wide variety of system log entries and formats have made it difficult to implement a robust multivendor reject analysis program, and logs do not always include all relevant information. The increased use of digital detectors exacerbates this problem because of higher reject rates associated with digital radiography compared with computed radiography. In this article, the authors report on the development of a unified database for vendor-neutral reject analysis across multiple sites within an academic institution and share their experience from a team-based approach to reduce reject rates.

  2. 46 CFR 54.25-8 - Radiography (modifies UW-11(a), UCS-57, UNF-57, UHA-33, and UHT-57).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Radiography (modifies UW-11(a), UCS-57, UNF-57, UHA-33... Radiography (modifies UW-11(a), UCS-57, UNF-57, UHA-33, and UHT-57). (a) Full radiography is required for all... requirements.) (b) Class II-L vessels shall be spot radiographed. The exemption provided in UW-11(c) of...

  3. 42 CFR Appendix G to Part 75 - Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Dental Assistants in Dental Radiography G Appendix G to Part 75 Public Health PUBLIC HEALTH SERVICE...—Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography The following section... individual State licensure processes, all of which include assessment of competence in dental radiography....

  4. 42 CFR Appendix G to Part 75 - Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Dental Assistants in Dental Radiography G Appendix G to Part 75 Public Health PUBLIC HEALTH SERVICE...—Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography The following section... individual State licensure processes, all of which include assessment of competence in dental radiography....

  5. 42 CFR Appendix G to Part 75 - Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Dental Assistants in Dental Radiography G Appendix G to Part 75 Public Health PUBLIC HEALTH SERVICE...—Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography The following section... individual State licensure processes, all of which include assessment of competence in dental radiography....

  6. 42 CFR Appendix G to Part 75 - Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Dental Assistants in Dental Radiography G Appendix G to Part 75 Public Health PUBLIC HEALTH SERVICE...—Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography The following section... individual State licensure processes, all of which include assessment of competence in dental radiography....

  7. Management of intra-abdominal hypertension and abdominal compartment syndrome: a review

    PubMed Central

    2014-01-01

    Patients in the intensive care unit (ICU) are at risk of developing of intra abdominal hypertension (IAH) and abdominal compartment syndrome (ACS). Aim: This review seeks to define IAH and ACS, identify the aetiology and presentation of IAH and ACS, identify IAP measurement techniques, identify current management and discuss the implications of IAH and ACS for nursing practice. A search of the electronic databases was supervised by a health librarian. The electronic data bases Cumulative Index of Nursing and Allied Health Literature (CINAHL); Medline, EMBASE, and the World Wide Web was undertaken from 1996- January 2011 using MeSH and key words which included but not limited to: abdominal compartment syndrome, intra -abdominal hypertension, intra-abdominal pressure in adult populations met the search criteria and were reviewed by three authors using a critical appraisal tool. Data derived from the retrieved material are discussed under the following themes: (1) etiology of intra-abdominal hypertension; (2) strategies for measuring intra-abdominal pressure (3) the manifestation of abdominal compartment syndrome; and (4) the importance of nursing assessment, observation and interventions. Intra-abdominal pressure (IAP) and abdominal compartment syndrome (ACS) have the potential to alter organ perfusion and compromise organ function. PMID:24499574

  8. Torsion of an intra-abdominal testis.

    PubMed

    Lewis; Roller; Parra; Cotlar

    2000-09-01

    To present a case of torsion of a nonneoplastic intra-abdominal testis with an unusual clinical presentation.A 26-year-old active duty Navy Petty Officer presented to the emergency department on 3 occasions over a 5-day period with lower abdominal pain. Physical examination demonstrated acute tenderness in the left lower quadrant with sugestion of a normal spermatic cord and atrophic testis in the left scrotum. Computed tomography scan demonstrated an intra-abdominal lesion near the internal inguinal ring. The patient underwent surgical exploration through an inguinal incision. Torsion of a nonviable intra-abdominal testis was present. The scrotum contained only the vas deferens and cremasteric muscle. An orchiectomy was performed with removal of the vas deferens and other cord structures.The unusual clinical finding of acute torsion of an intra-abdominal testis, associated with an apparent atrophic scrotal testis, presented a confusing clinical picture. Computed tomography scan did not clarify the issue sufficiently to establish a definite preoperative diagnosis. Clinical suspicion prompted early surgical intervention. Review of the current literature produced 60 reported cases of torsion of an intra-abdominal testis. Two thirds of these involved testicular neoplasm, usually seminoma. Although the clinical presentation varied, most patients had recent onset of lower abdominal pain associated with tenderness and, in half the cases, a mass. Patients almost always presented with an absent scrotal testis on the involved side, and not infrequently reported previous surgery thought to be an orchiectomy.Diagnosis of an intra-abdominal testicular torsion is rare, particularly when no neoplasm is present. A high index of suspicion must be maintained whenever there is abdominal pain and undescended testis. The surgical history and imaging studies may not clarify a confusing clinical picture.

  9. Correlation of X-Ray Vector Radiography to Bone Micro-Architecture

    NASA Astrophysics Data System (ADS)

    Schaff, Florian; Malecki, Andreas; Potdevin, Guillaume; Eggl, Elena; Noël, Peter B.; Baum, Thomas; Garcia, Eduardo Grande; Bauer, Jan S.; Pfeiffer, Franz

    2014-01-01

    Besides the overall mass density, strength of trabecular bone depends significantly on its microstructure. However, due to dose constraints in medical CT imaging, it is impossible to gain sufficient information about very fine bone structures in vivo on the micrometer scale. Here we show that a recently developed method of X-ray vector radiography (XVR), an imaging method which uses X-ray scattering information to form an image, allows predictions on the bone microstructure without the explicit need to spatially resolve even individual trabeculae in the bone. We investigated thick human femoral bone samples and compared state-of-the-art μCT data with XVR imaging. A model is presented which proves that XVR imaging yields information directly correlated with the trabecular microstructure. This opens up possibilities of using XVR as a tool to help early diagnosis of bone diseases, such as osteoporosis.

  10. Ultrafast proton radiography of the magnetic fields generated by a laser-driven coil current

    DOE PAGES

    Gao, Lan; Ji, Hantao; Fiksel, Gennady; ...

    2016-04-15

    Magnetic fields generated by a current flowing through a U-shaped coil connecting two copper foils were measured using ultrafast proton radiography. Two ~ 1.25 kJ, 1-ns laser pulses propagated through laser entrance holes in the front foil and were focused to the back foil with an intensity of ~ 3 x 1016 W/cm2. The intense laser-solid interaction induced a high voltage between the copper foils and generated a large current in the connecting coil. The proton data show ~ 40-50 T magnetic fields at the center of the coil ~ 3-4 ns after laser irradiation. In conclusion, the experiments providemore » significant insight for future target designs that aim to develop a powerful source of external magnetic fields for various applications in high-energy-density science.« less

  11. Ultrafast proton radiography of the magnetic fields generated by a laser-driven coil current

    SciTech Connect

    Gao, Lan; Ji, Hantao; Fiksel, Gennady; Fox, William; Evans, Michelle; Alfonso, Noel

    2016-04-15

    Magnetic fields generated by a current flowing through a U-shaped coil connecting two copper foils were measured using ultrafast proton radiography. Two ~ 1.25 kJ, 1-ns laser pulses propagated through laser entrance holes in the front foil and were focused to the back foil with an intensity of ~ 3 x 1016 W/cm2. The intense laser-solid interaction induced a high voltage between the copper foils and generated a large current in the connecting coil. The proton data show ~ 40-50 T magnetic fields at the center of the coil ~ 3-4 ns after laser irradiation. In conclusion, the experiments provide significant insight for future target designs that aim to develop a powerful source of external magnetic fields for various applications in high-energy-density science.

  12. Development of an online automatic computed radiography dose data mining program: a preliminary study.

    PubMed

    Ng, Curtise K C; Sun, Zhonghua

    2010-01-01

    Recent studies have reported the computed radiography (CR) dose creep problem and therefore the need to have monitoring processes in place in clinical departments. The objective of this study is to provide a better technological solution to implement a regular CR dose monitoring process. An online automatic CR dose data mining program which can be applied to different systems was developed based on freeware and existing softwares in the Picture Archiving and Communication System (PACS) server. The program was tested with 69 CR images. This preliminary study shows that the program addresses the major weaknesses of some existing studies including involvement of manual procedures in the monitoring process and being only applicable to a single manufacturer's CR images. The proposed method provides an efficient and effective solution to implement a CR dose monitoring program regularly in busy clinical departments to regulate the dose creep problem so as to reinforce the 'As Low As Reasonably Achievable' (ALARA) principle.

  13. Hugoniot Measurements at Low Pressures in Tin Using 800 MeV proton Radiography

    SciTech Connect

    Schwartz, Cynthia; Hogan, Gary E; King, Nicholas S. P.; Kwiathowski, Kris K.; Mariam, Fesseha G.; Marr-Lyon, Mark; McNeil, Wendy Vogan; Merrill, Frank E.; Morris, Christopher; Rightley, Paul; Saunders, Alexander

    2009-08-05

    A 2cm long 8 mm diameter cylindrical tin target has been shocked to a pressure in the region of the {beta} {yields} {gamma} phase change using a small, low density PETN charge mounted on the opposite side of a stainless steel diaphragm. The density jump and shock velocity were measured radiographically as the shock wave moved through the sample and the pressure dropped, using the proton radiography facility at LANL. This provided a quasi-continuous record of the equations of state along the Hugoniot for the P1 wave from a shock velocity of 3.25 km/sec down to near the sound speed. Edge release effects were removed from the data using tomographic techniques. The data show evidence for a phase transition that extends over a broad pressure range. The data and analysis will be presented.

  14. Diagnostic Ultrasonography of an Ankle Fracture Undetectable by Conventional Radiography: A Case Report

    PubMed Central

    Daniels, Clinton J.; Welk, Aaron B.; Enix, Dennis E.

    2016-01-01

    Objective The purpose of this study is to present diagnostic ultrasonography assessment of an occult fracture in a case of persistent lateral ankle pain. Clinical Features A 35-year-old woman presented to a chiropractic clinic with bruising, swelling, and pain along the distal fibula 3 days following an inversion ankle trauma. Prior radiographic examination at an urgent care facility was negative for fracture. Conservative care over the next week noted improvement in objective findings, but the pain persisted. Intervention and Outcome Diagnostic ultrasonography was ordered to assess her persistent ankle pain and showed a minimally displaced fracture of the fibula 4 cm proximal to the lateral malleolus. The patient was referred to her primary care physician and successfully managed with conservative care. Conclusion In this case, diagnostic ultrasonography was able to identify a Danis-Weber subtype B1 fracture that was missed by plain film radiography. PMID:27069430

  15. Fraudulent use of digital radiography: methods to detect and protect digital radiographs.

    PubMed

    Calberson, Filip L G; Hommez, Geert M; De Moor, Roeland J

    2008-05-01

    Digital radiography has become an indispensable diagnostic tool in dentistry today. To improve vision and diagnosis, dental x-ray software allows image enhancement (eg, adjusting color, density, sharpness, brightness, or contrast). Exporting digital radiographs to a file format compatible with commercial graphic software increases chances that information can be altered, added, or removed in an unethical manner. Dental radiographs are easily duplicated, stored, or distributed in digital format. It is difficult to guarantee the authenticity of digital images, which is especially important in insurance or juridic cases. Image-enhancement features applied to digital radiographs allow mishandling or potential abuse. This has been illustrated by several recently published studies. A standard authentication procedure for digital radiographs is needed. A number of manipulated radiographic images are presented to show concerns about security, reliability, and the potential for fraud. Antitampering techniques and methods of detecting manipulations in digital medical images are discussed.

  16. Advances in abdominal MR imaging.

    PubMed

    Ferrucci, J T

    1998-01-01

    Major technical advances in MR imaging have led to its wider use in the evaluation of abdominal disease. The principle new pulse sequence is the RARE sequence for T2-weighted imaging. Multishot and breath-hold single-shot RARE techniques are now widely used, and both have performed as well as conventional spin-echo imaging with far shorter acquisition times. The most notable improvements have been in the detection and characterization of hepatic lesions. Two liver-specific contrast agents received FDA approval during 1997: SPIO particles or ferumoxide and mangafodipir trisodium, a hepatocyte-specific agent. Both of these agents provide considerable benefit in the detection and characterization of hepatic lesions. Manganese enhancement has also proved useful in MR imaging of the pancreas, although fat-suppressed T1-weighted imaging with dynamic gadolinium enhancement has also yielded results comparable with those of contrast-enhanced CT. MR hydrography, a generic term for static fluid imaging, is another derivative of RARE fast T2-weighted imaging. MRCP, the best known example of MR hydrography, has been rapidly and widely employed as a primary method for imaging the biliary and pancreatic ducts and has become competitive with ERCP. MR vascular imaging, especially portal venography, has been used for noninvasive imaging of portal venous disease in Budd Chiari disease, before placement of transjugular intrahepatic portosystemic shunts, and for pancreatic cancer staging. Finally, the development of conventional phased-array body coils and endorectal coils has enabled high-quality MR imaging of perirectal disease (including Crohn disease, fistula in ano, and postpartum sphincter dysfunction). Future abdominal applications of MR imaging will involve second-generation MR interventional techniques, including use of open systems, functional or diffusion-weighted imaging exploiting the molecular activity of tissues, and virtual MR endoscopy. Although CT continues to evolve

  17. The sensitivity of radiography of the postoperative stomach

    SciTech Connect

    Ott, D.J.; Munitz, H.A.; Gelfand, D.W.; Lane, T.G.; Wu, W.C.

    1982-09-01

    The results of radiology and endoscopy were compared in 140 patients who had undergone gastric surgery for ulcer disease. Of 74 patients who were examined with single-contrast radiography, 37 had abnormalities that were demonstrated endoscopically. The radiographic sensitivities in these patients were: gastritis 2/22 (9%); ulcer 3/5 (60%); obstruction 8/8 (100%); and miscellaneous abnormalities 2/2 (100%). The predictive accuracy of a diagnois of ulcer was 38%. Of the 66 patients who were examined with double-contrast radiography, 33 abnormalities were found with endoscopy. The radiographic sensitivities were: gastritis 3/13 (23%); ulcer 7/10 (70%); obstruction 4/4 (100%); and miscellaneous abnormalities 6/6 (100%). The predictive accuracy of a diagnosis of ulcer was 44%. Radiology appears to be unreliable in diagnosing gastritis and recurrent ulceration in the post-operation stomach. The double-contrast technique does not offer significant improvement over the single-contrast method in evaluating these postoperative problems.

  18. Grating Based, Phase Contrast Radiography with Bremsstrahlung Source

    SciTech Connect

    Fletcher Goldin and Shaun Hampton

    2009-09-11

    Phase-contrast radiography (PCR) generates an image from gradients in the phase of the probing X-radiation induced by the radiographic object, and can therefore make visible features difficult or impossible to see with conventional, absorption-contrast (ACR) radiography. For any particular object, variations in either the real or imaginary parts of the index of refraction could be greater. Most practical difficulties of PCR arise from the very small deviation from unity (~10-5-10-6, depending of material and energy) of the real part of the index of refraction. In principal, straightforward shadowgraphy would provide a phase-contrast image, but in practice this is usually overwhelmed by the zero-order (bright field) signal. Eliminating this sets the phase-contrast signal against a dark field (as in Schlieren photography with visible light). One way to do this with X-rays is with a grating that produces a Talbot interference pattern. Minute variations in optical path lengths through the radiographic object can significantly shift the Talbot fringes, and these shifts constitute a dark-field signal separate from the zero-order wave. This technique has recently been investigated up to ~20keV [1-3]; this work addresses what sets the practical upper limit, and where that limit is. These appear to be grating fabrication, and ~60keV, respectively.

  19. A note on digital dental radiography in forensic odontology.

    PubMed

    Chiam, Sher-Lin

    2014-09-01

    Digital dental radiography, intraoral and extraoral, is becoming more popular in dental practice. It offers convenience, such as lower exposure to radiation, ease of storing of images, and elimination of chemical processing. However, it also has disadvantages and drawbacks. One of these is the potential for confusion of the orientation of the image. This paper outlines one example of this, namely, the lateral inversion of the image. This source of confusion is partly inherent in the older model of phosphor storage plates (PSPs), as they allow both sides to be exposed without clue to the fact that the image is acquired on the wrong side. The native software allows digital manipulation of the X-ray image, permitting both rotation and inversion. Attempts to orientate the X-ray according to the indicator incorporated on the plate can then sometimes lead to inadvertent lateral inversion of the image. This article discusses the implications of such mistakes in dental digital radiography to forensic odontology and general dental practice.

  20. Development of a Logging Tool for Muon Radiography

    NASA Astrophysics Data System (ADS)

    Suenaga, H.; Kiho, K.; Miyakawa, K.; Tanaka, H.

    2012-04-01

    A research for high level radioactive waste disposal should investigate geological structure and saturation change of rock mass around a disposal cavern. In the CO2 geological storage and the underground storage of crude oil, natural gas or liquefied petroleum gas (LPG), it is necessary to monitor an upward migration of a gaseous fluid which is stored in underground. For an investigation of slope stability, it is effective to evaluate a high saturation area in the ground's pore space as the area should be the same as that of a rainfall infiltration. Since these phenomena could be evaluated by a measurement of a density variation in underground rock, an application of muon radiography is highly prospective. The Central Research Institute of Electric Power Industry (CRIEPI) has a plan to conduct a field experiment to evaluate an applicability of the muon radiography to engineering geology in cooperation with Electric Power Development Co., Ltd. (J-POWER). The field experiment will be performed this year in slope topography. If the applicability will be revealed as a result of the field experiment, CRIEPI will start a research on development of a logging tool which can measure muon in a borehole. We plan to build a prototype of the logging tool in around three years and will put it into practical use in around five years.

  1. Multiple-Image Radiography for Human Soft Tissue

    SciTech Connect

    Muehleman,C.; Li, J.; Zhong, Z.; Brankov, J.; Wernick, M.

    2006-01-01

    Conventional radiography only provides a measure of the X-ray attenuation caused by an object; thus, it is insensitive to other inherent informative effects, such as refraction. Furthermore, conventional radiographs are degraded by X-ray scatter that can obscure important details of the object being imaged. The novel X-ray technology diffraction-enhanced imaging (DEI) has recently allowed the visualization of nearly scatter-free images displaying both attenuation and refraction properties. A new method termed multiple-image radiography (MIR) is a significant improvement over DEI, corrects errors in DEI, is more robust to noise and produces an additional image that is entirely new to medical imaging. This new image, which portrays ultra-small-angle X-ray scattering (USAXS) conveys the presence of microstructure in the object, thus differentiating homogeneous tissues from tissues that are irregular on a scale of micrometers. The aim of this study was to examine the use of MIR for evaluation of soft tissue, and in particular to conduct a preliminary investigation of the USAXS image, which has not previously been used in tissue imaging.

  2. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  3. The need for skull radiography in patients presenting for CT

    SciTech Connect

    Tress, B.M.

    1983-01-01

    One thousand patients had both CT of the head and a conventional skull series of radiographs. Radiographic findings were abnormal in 250 patients (25%), but only 64 patients (6.4%) had diagnostically significant abnormalities at radiography that were not detected by CT. If the 163 patients who presented after acute trauma were excluded from the series, only 39 (4.7%) of the remaining patients had radiographically significant abnormal findings that were not seen at CT, and only two (0.2%) of these abnormalities could not be diagnosed by a lateral skull radiograph alone. In only five patients (0.5%) was the management actively changed because an abnormaltiy that was detected at skull radiography was not detected at CT. Thus, in nontrauma patients who have stroke, epilepsy, dementia, or non-specific symptoms without focal signs, or have recently undergone craniotomy, and who have been referred for CT, skull radiographs are not justified. In the patient with a history and findings that are strongly suggestive of a pathological disorder anywhere other than in the sella turcica, cerebello-pontine angle, and paranasal sinuses, only the lateral skull radiograph should be obtained after CT, and only if CT is equivocal.

  4. Value of radiography in the management of possible fishbone ingestion.

    PubMed

    Sundgren, P C; Burnett, A; Maly, P V

    1994-08-01

    A retrospective study was performed on 42 consecutive patients to examine the value of radiography in the management of complaints of fishbone ingestion. All patients underwent an oral examination followed by radiographic examination with plain films, barium swallows, barium and water swallows, and an endoscopic examination. All radiographs were reviewed by two unbiased, experienced radiologists. Of the 7 cases with fishbone found at endoscopic examination, only two (29%) bones were seen by the primary radiologist and 5 (71%) by the reviewing radiologists. Except for one case in which all three radiologists detected a fishbone that passed during the examination, and thereby was not found on endoscopy, no fishbones were found at the radiographic examination that were not seen on the endoscopic examination. Thus, radiography added no valuable information but only delayed the endoscopic examination with ensuing removal of the foreign body, which had to be performed regardless of the outcome of the radiographic examination. Therefore, we suggest that patients with a short history of complaints of fishbone ingestion, ie, 48 hours or less, should first be evaluated with oral and endoscopic examination.

  5. Low material budget floating strip Micromegas for ion transmission radiography

    NASA Astrophysics Data System (ADS)

    Bortfeldt, J.; Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph.; Magallanes, L.; Müller, R.; Parodi, K.; Schlüter, T.; Voss, B.; Zibell, A.

    2017-02-01

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm2 with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X0. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF4 gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  6. Multiple pixel-scale soil water retention curves quantified by neutron radiography

    NASA Astrophysics Data System (ADS)

    Kang, M.; Perfect, E.; Cheng, C. L.; Bilheux, H. Z.; Lee, J.; Horita, J.; Warren, J. M.

    2014-03-01

    The soil water retention function is needed for modeling multiphase flow in porous media. Traditional techniques for measuring the soil water retention function, such as the hanging water column or pressure cell methods, yield average water retention data which have to be modeled using inverse procedures to extract relevant point parameters. In this study, we have developed a technique for directly measuring multiple point (pixel-scale) water retention curves for a repacked sand material using 2-D neutron radiography. Neutron radiographic images were obtained under quasi-equilibrium conditions at nine imposed basal matric potentials during monotonic drying of Flint sand at the High Flux Isotope Reactor (HFIR) Cold Guide (CG) 1D beamline at Oak Ridge National Laboratory. All of the images were normalized with respect to an image of the oven dry sand column. Volumetric water contents were computed on a pixel by pixel basis using an empirical calibration equation after taking into account beam hardening and geometric corrections. Corresponding matric potentials were calculated from the imposed basal matric potential and pixel elevations. Volumetric water content and matric potential data pairs corresponding to 120 selected pixels were used to construct 120 point water retention curves. Each curve was fitted to the Brooks and Corey equation using segmented non-linear regression in SAS. A 98.5% convergence rate was achieved resulting in 115 estimates of the four Brooks and Corey parameters. A single Brooks and Corey point water retention function was constructed for Flint sand using the median values of these parameter estimates. This curve corresponded closely with the point Brooks and Corey function inversely extracted from the average water retention data using TrueCell. Forward numerical simulations performed using HYDRUS 1-D showed that the cumulative outflows predicted using the point Brooks and Corey functions from both the direct (neutron radiography) and

  7. [Laparoscopic abdominal drainage by sterile destructive pancreatitis].

    PubMed

    Kuznetsov, N A; Rodoman, G V; Shalaeva, T I; Trefilova, O I; Sosikova, N L

    2009-01-01

    90 patients with acute pancreatitis were observed, in 60 of them laparoscopic drainage was performed. The procedure by sterile pancreatonecrosis is indicated only in presence of extent amount of exudate in abdominal cavity. Duration of draining the abdominal cavity should be strictly limited because of the high risk of septic complications. Contraindications for the abdominal drainage by acute necrotic pancreatitis are not only adhesions in the abdomen and shock state of the patient at the moment of procedure necessity, but also unstable hemodynamics in anamnesis and even by the arterial pressure downtrend.

  8. Soft tissue coverage in abdominal wall reconstruction.

    PubMed

    Baumann, Donald P; Butler, Charles E

    2013-10-01

    Abdominal wall defects requiring soft tissue coverage can be either partial-thickness defects or full-thickness composite defects. Soft tissue flap reconstruction offers significant advantages in defects that cannot be closed primarily. Flap reconstruction is performed in a single-stage procedure obviating chronic wound management. If the defect size exceeds the availability of local soft tissue for coverage, regional pedicled flaps can be delivered into the abdominal wall while maintaining blood supply from their donor site. Microsurgical free tissue transfer increases the capacity to provide soft tissue coverage for abdominal wall defects that are not amenable to either local or regional flap coverage.

  9. Intra-abdominal bleeding in appendicitis.

    PubMed

    Thongprayoon, C; Pasa-Arj, S

    1991-08-01

    A 34-year-old woman, gravida 6 with 10 weeks of gestation was admitted because of abdominal pain and fainting. On physical examination she had hypotension, was pale with abdominal tenderness and guarding. Culdocentesis yielded unclotted blood. Immediate laparotomy was performed, because a diagnosis of ectopic pregnancy was made. About 2,500 ml of fresh blood was found in the abdominal cavity. Appendicular artery tear caused active arterial bleeding. The torn appendicular artery was observed to be the consequence of perforated appendicitis, which, in turn, was caused by a faecalith. Appendectomy was performed and she made a good recovery.

  10. Laparoscopic repair of abdominal incisional hernia

    PubMed Central

    Yang, Xue-Fei

    2016-01-01

    Abdominal incisional hernia is a common complication after open abdominal operations. Laparoscopic procedures have obvious mini-invasive advantages for surgical treatment of abdominal incisional hernia, especially to cases with big hernia defect. Laparoscopic repair of incisional hernia has routine mode but the actual operations will be various according to the condition of every hernia. Key points of these operations include design of the position of trocars, closure of defects and fixation of meshes. The details of these issues and experiences of perioperative evaluation and treatment will be talked about in this article. PMID:27761446

  11. High-ratio grid considerations in mobile chest radiography

    SciTech Connect

    Scott, Alexander W.; Gauntt, David M.; Yester, Michael V.; Barnes, Gary T.

    2012-06-15

    Purpose: Grids are often not used in mobile chest radiography, and when used, they have a low ratio and are often inaccurately aligned. Recently, a mobile radiography automatic grid alignment system (MRAGA) was developed that accurately and automatically aligns the focal spot with the grid. The objective of this study is to investigate high-ratio grid tradeoffs in mobile chest radiography at fixed patient dose when the focal spot lies on the focal axis of the grid. Methods: The chest phantoms (medium and large) used in this study were modifications of the ANSI (American National Standards Institute) chest phantom and consisted of layers of Lucite Trade-Mark-Sign , aluminum, and air. For the large chest phantom, the amount of Lucite and aluminum was increased by 50% over the medium phantom. Further modifications included a mediastinum insert and the addition of contrast targets in the lung and mediastinum regions. Five high-ratio grids were evaluated and compared to the nongrid results at x-ray tube potentials of 80, 90, 100, and 110 kVp for both phantoms. The grids investigated were from two manufacturers: 12:1 and 15:1 aluminum interspace grids from one and 10:1, 13:1, and 15:1 fiber interspace grids from another. MRAGA was employed to align the focal spot with the grid. All exposures for a given kVp and phantom size were made using the same current-time product (CTP). The phantom images were acquired using computed radiography, and contrast-to-noise ratios (CNR) and CNR improvement factors (k{sub CNR}) were determined from the resultant images. The noise in the targets and the contrast between the targets and their backgrounds were calculated using a local detrending correction, and the CNR was calculated as the ratio of the target contrast to the background noise. k{sub CNR} was defined as the ratio of the CNR imaged with the grid divided by the CNR imaged without a grid. Results: The CNR values obtained with a high-ratio grid were 4%-65% higher than those

  12. Coronary calcium visualization using dual energy chest radiography with sliding organ registration

    NASA Astrophysics Data System (ADS)

    Wen, Di; Nye, Katelyn; Zhou, Bo; Gilkeson, Robert C.; Wilson, David L.

    2016-03-01

    Coronary artery calcification (CAC) is the lead biomarker for atherosclerotic heart disease. We are developing a new technique to image CAC using ubiquitously ordered, low cost, low radiation dual energy (DE) chest radiography (using the two-shot GE Revolution XRd system). In this paper, we proposed a novel image processing method (CorCalDx) based on sliding organ registration to create a bone-image-like, coronary calcium image (CCI) that significantly reduces motion artifacts and improves CAC conspicuity. Experiments on images of a physical dynamic cardiac phantom showed that CorCalDx reduced 73% of the motion artifact area as compared to standard DE over a range of heart rates up to 90 bpm and varying x-ray radiation exposures. Residual motion artifact in the phantom CCI is greatly suppressed in gray level and area (0.88% of the heart area). In a Functional Measurement Test (FMT) with 20 clinical exams, image quality improvement of CorCalDx against standard DE (measured from -10 to +10) was significantly suggested (p<0.0001) by three radiologists for cardiac motion artifacts (7.2+/-2.1) and cardiac anatomy visibility (6.1+/-3.5). CorCalDx was always chosen best in every image tested. In preliminary assessments of 12 patients with 18 calcifications, 90% of motion artifact regions in standard DE results were removed in CorCalDx results, with 100% sensitivity of calcification detection, showing great potential of CorCalDx to improve CAC detection and grading in DE chest radiography.

  13. Quantifying moisture transport in cementitious materials using neutron radiography

    NASA Astrophysics Data System (ADS)

    Lucero, Catherine L.

    . It has been found through this study that small pores, namely voids created by chemical shrinkage, gel pores, and capillary pores, ranging from 0.5 nm to 50 microm, fill quickly through capillary action. However, large entrapped and entrained air voids ranging from 0.05 to 1.25 mm remain empty during the initial filling process. In mortar exposed to calcium chloride solution, a decrease in sorptivity was observed due to an increase in viscosity and surface tension of the solution as proposed by Spragg et al 2011. This work however also noted a decrease in the rate of absorption due to a reaction between the salt and matrix which results in the filling of the pores in the concrete. The results from neutron imaging can help in the interpretation of standard absorption tests. ASTM C1585 test results can be further analyzed in several ways that could give an accurate indication of the durability of the concrete. Results can be reported in depth of penetration versus the square root of time rather than mm3 of fluid per mm2 of exposed surface area. Since a known fraction of pores are initially filling before reaching the edge of the sample, the actual depth of penetration can be calculated. This work is compared with an 'intrinsic sorptivity' that can be used to interpret mass measurements. Furthermore, the influence of shrinkage reducing admixtures (SRAs) on drying was studied. Neutron radiographs showed that systems saturated in water remain "wetter" than systems saturated in 5% SRA solution. The SRA in the system reduces the moisture diffusion coefficient due an increase in viscosity and decrease in surface tension. Neutron radiography provided spatial information of the drying front that cannot be achieved using other methods.

  14. Xanthogranulomatous panniculitis after spillage of gallstones during laparoscopic cholecystectomy mimics intra-abdominal malignancy.

    PubMed

    Lin, Chien-Hua; Chu, Heng-Cheng; Hsieh, Huan-Fa; Jin, Jong-Shiaw; Yu, Jyh-Cherng; Cheng, Ming-Fang; Hsu, Sheng-Der; Chan, De-Chuan

    2006-08-01

    Spillage of gallstones into the peritoneal cavity during laparoscopic cholecystectomy (LC) occurs frequently and may be associated with complications. Most of these complications present late after the original procedure, and many have clinical pictures that are not related to biliary etiology, which can confound and delay adequate management. Our patient presented with an intra-abdominal firm heterogeneous mass lesion. Imaging studies showed obvious abdominal wall invasion, and CA-125 level was elevated. Thus, malignancy could not be excluded. Final operative pathology revealed xanthogranulomatous inflammation. Complications of LC should be considered for patients with intra-abdominal abscess or mass lesion if there is a history of LC, regardless of time interval.

  15. [Churg-Strauss abdominal manifestation].

    PubMed

    Suarez-Moreno, Roberto; Ponce-Pérez, Luis Virgilio; Margain-Paredes, Miguel Angel; Garza-de la Llave, Heriberto; Madrazo-Navarro, Mario; Espinosa-Álvarez, Arturo

    2014-01-01

    Antecedentes: la enfermedad de Churg-Strauss es poco común, idiopática, caracterizada por hipereosinofilia en sangre y tejidos, aunada a vasculitis sistémica en pacientes con antecedentes de asma o rinitis alérgica. Las manifestaciones gastrointestinales del síndrome de Churg Strauss se caracterizan por dolor abdominal, seguido de diarrea y hemorragia en 31-45% de los casos. Caso clínico: paciente masculino con antecedente de asma que acudió a consulta por abdomen agudo con probable apendicitis aguda; durante el protocolo de estudio se diagnosticó síndrome de Churg Strauss, con manifestaciones intestinales. Conclusión: el síndrome de Churg Strauss es una vasculitis poco frecuente que puede manifestarse con síntomas intestinales, como en este caso; es importante tenerlo en mente a la hora de los diagnósticos diferenciales. Existen pocos reportes con este síndrome asociado con abdomen agudo, todos ellos con mal pronóstico.

  16. Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

    SciTech Connect

    Theocharopoulos, Nicholas; Chatzakis, Georgios; Damilakis, John

    2009-10-15

    Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional

  17. [Inflammatory aneurysms of the abdominal aorta].

    PubMed

    Tovar Martín, E; Acea Nebril, B

    1993-01-01

    Approximately 10 per cent of abdominal aneurysms have an excessively thick wall that sometimes involve duodenum, cava or colon by an inflammatory process. Between February 1986 and December 1992, 147 patients with abdominal aortic aneurysm (AAA) were treated surgically and in 13 (8.8%) the aneurysms were found to be inflammatory. Their mean age was 67.3 years (70.1 years in non inflammatory group) and all were symptomatics initially (abdominal pain in 53%, rupture in 23%, mass in 15%). The operative mortality for elective resection was 37% in patients with inflammatory abdominal aortic aneurysms (IAAA) decreasing to 9% in the AAA group without inflammatory involvement. We conclude that surgery is indicated in these patients to prevent rupture and to hasten the subsidense of inflammatory process ever with postoperative morbi-mortality increased.

  18. Intravenous dihydroergotamine therapy for pediatric abdominal migraines.

    PubMed

    Raina, Madiha; Chelimsky, Gisela; Chelimsky, Thomas

    2013-10-01

    Abdominal migraines present with debilitating symptoms in adolescence. At our institution, the gastroenterology, neurology, and autonomic departments collaborated in treating patients with such presentations. This case series describes 6 patients who were given intravenous dihydroergotamine (DHE) for presumed abdominal migraines. DHE was only used when other agents like amitriptyline, verapamil, topiramate, or depakote had proved ineffective. DHE was started at 0.5 mg dose and on average 7 to 9 mg were given on each hospitalization. Patient ages ranged from 13 to 19 years with the majority being female. One patient did not respond to treatment. One patient was admitted 4 times for symptoms of abdominal migraines resolving with DHE. The average time between symptom relapse was about 5 to 12 months. Five of our 6 patients responded to the infusion without significant side effects. Based on these case series, DHE may be a treatment option in children with intractable abdominal migraine.

  19. [Late primary abdominal pregnancy. Case report].

    PubMed

    Farías, Emigdio Torres; Gómez, Luis Guillermo Torres; Allegre, René Márquez; Higareda, Salvador Hernández

    2008-09-01

    Abdominal advanced pregnancy is an obstetric complication that put at risk maternal and fetal life. We report a case of advanced abdominal pregnancy with intact ovaries and fallopian tubes, without ureteroperitoneal fistulae and, late prenatal diagnosis, in a multiparous patient without risk factors, with alive newborn, and whose pregnancy was attended at Unidad Medica de Alta Especialidad, Hospital de Gineco-Obstetricia, Centro Medico Nacional de Occidente del IMSS, Guadalajara, Jalisco, México.

  20. Selective Nonoperative Management of Abdominal Stab Wounds.

    PubMed

    Murry, Jason S; Hoang, David M; Ashragian, Sogol; Liou, Doug Z; Barmparas, Galinos; Chung, Rex; Alban, Rodrigo F; Margulies, Daniel R; Ley, Eric J

    2015-10-01

    Stab wounds (SW) to the abdomen traditionally require urgent exploration when associated with shock, evisceration, or peritonitis. Hemodynamically stable patients without evisceration may benefit from serial exams even with peritonitis. We compared patients taken directly to the operating room with abdominal SWs (ED-OR) to those admitted for serial exams (ADMIT). We retrospectively reviewed hemodynamically stable patients presenting with any abdominal SW between January 2000 and December 2012. Exclusions included evidence of evisceration, systolic blood pressure ≤110 mm Hg, or blood transfusion. NON-THER was defined as abdominal exploration without identification of intra-abdominal injury requiring repair. Of 142 patients included, 104 were ED-OR and 38 were ADMIT. When ED-OR was compared with ADMIT, abdominal Abbreviated Injury Score was higher (2.4 vs 2.1; P = 0.01) and hospital length of stay was longer (4.8 vs 3.3 days; P = 0.04). Incidence of NON-THER was higher in ED-OR cohort (71% vs 13%; P ≤ 0.001). In a regression model, ED-OR was a predictor of NON-THER (adjusted odds ratio 16.6; P < 0.001). One patient from ED-OR expired after complications from NON-THER. There were no deaths in the ADMIT group. For those patients with abdominal SWs who present with systolic blood pressure ≥110 mm Hg, no blood product transfusion in the emergency department and lacking evisceration, admission for serial abdominal exams may be preferred regardless of abdominal exam.

  1. Progress in Fully Automated Abdominal CT Interpretation

    PubMed Central

    Summers, Ronald M.

    2016-01-01

    OBJECTIVE Automated analysis of abdominal CT has advanced markedly over just the last few years. Fully automated assessment of organs, lymph nodes, adipose tissue, muscle, bowel, spine, and tumors are some examples where tremendous progress has been made. Computer-aided detection of lesions has also improved dramatically. CONCLUSION This article reviews the progress and provides insights into what is in store in the near future for automated analysis for abdominal CT, ultimately leading to fully automated interpretation. PMID:27101207

  2. Abdominal apoplexy resulting in small bowel obstruction

    PubMed Central

    Le, Don; Guileyardo, Joseph; Casanova, Mark

    2016-01-01

    Abdominal apoplexy is a rare hemorrhagic condition involving the small arteries or veins within the abdominal cavity. A high degree of clinical suspicion, followed by appropriate diagnostic workup and therapeutic intervention, is critical, as nonoperative mortality approaches 100%. Contrary to most previously reported cases, which were associated with hemoperitoneum, we present a patient in which gastroduodenal artery dissection resulted in an organized retroperitoneal hematoma with local compression of the duodenum and subsequent bowel obstruction, resulting in vomiting, aspiration, and death. PMID:27695177

  3. Initial results from a multiple monoenergetic gamma radiography system for nuclear security

    NASA Astrophysics Data System (ADS)

    O'Day, Buckley E.; Hartwig, Zachary S.; Lanza, Richard C.; Danagoulian, Areg

    2016-10-01

    The detection of assembled nuclear devices and concealed special nuclear materials (SNM) such as plutonium or uranium in commercial cargo traffic is a major challenge in mitigating the threat of nuclear terrorism. Currently available radiographic and active interrogation systems use ∼1-10 MeV bremsstrahlung photon beams. Although simple to build and operate, bremsstrahlung-based systems deliver high radiation doses to the cargo and to potential stowaways. To eliminate problematic issues of high dose, we are developing a novel technique known as multiple monoenergetic gamma radiography (MMGR). MMGR uses ion-induced nuclear reactions to produce two monoenergetic gammas for dual-energy radiography. This allows us to image the areal density and effective atomic number (Zeff) of scanned cargo. We present initial results from the proof-of-concept experiment, which was conducted at the MIT Bates Research and Engineering Center. The purpose of the experiment was to assess the capabilities of MMGR to measure areal density and Zeff of container cargo mockups. The experiment used a 3.0 MeV radiofrequency quadrupole accelerator to create sources of 4.44 MeV and 15.11 MeV gammas from the 11B(d,nγ)12C reaction in a thick natural boron target; the gammas are detected by an array of NaI(Tl) detectors after transmission through cargo mockups . The measured fluxes of transmitted 4.44 MeV and 15.11 MeV gammas were used to assess the areal density and Zeff. Initial results show that MMGR is capable of discriminating the presence of high-Z materials concealed in up to 30 cm of iron shielding from low- and mid-Z materials present in the cargo mockup.

  4. Digital versus conventional panoramic radiography in predicting inferior alveolar nerve injury after mandibular third molar removal.

    PubMed

    Szalma, József; Lempel, Edina; Jeges, Sára; Olasz, Lajos

    2012-03-01

    The aim of the study was to compare the accuracy of conventional and digital panoramic radiography (OPG) in relation to 4 specific high-risk signs (interruption of the superior cortical line, diversion, narrowing of the canal, and dark band of the root), which would indicate a close anatomic relationship between third molar roots and the inferior alveolar canal.Four hundred mandibular third molar surgical removals after conventional and 272 after digital radiographs were evaluated in the study. The association between postoperative inferior alveolar nerve (IAN) paresthesia and the presence of any preoperative high-risk signs in the OPG was investigated. Bivariate and multivariate logistic regression analyses were completed to compare the accuracy of conventional and digital radiographic techniques detecting high-risk signs predicting possible IAN paresthesia.Digital OPG results showed significantly higher sensitivity in diversion (P = 0.014) and narrowing (P < 0.002) of the canal, whereas the specificity of these signs was significantly lower (P < 0.001 and P = 0.035). The likelihood ratio analysis and multivariate logistic regression analysis did not prove the significant difference between digital and conventional imaging according to the examined high-risk signs. Positive predictive values of the signs were found in conventional radiography between 3.6% and 10.9%, whereas in the digital images, it ranged from 2.9% to 7.9%.The results of this study failed to prove significant difference between the accuracy of digital and conventional OPG for predicting IAN paresthesia, whereas low positive predictive values indicate both imaging techniques as inadequate screening methods for predicting IAN paresthesia after mandibular third molar removal.

  5. Novel scintillation detector design and performance for proton radiography and computed tomography

    PubMed Central

    Schulte, R. W.; Hurley, R. F.; Johnson, R. P.; Sadrozinski, H. F.-W.; Zatserklyaniy, A.; Plautz, T.; Giacometti, V.

    2016-01-01

    Purpose: Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to evaluate the water-equivalent path length (WEPL) of a proton passing through the object. A novel approach is presented for an inexpensive WEPL detector for pCT and proton radiography. Methods: A novel multistage detector with an aperture of 10 × 37.5 cm was designed to optimize the accuracy of the WEPL measurements while simplifying detector construction and the performance requirements of its components. The design of the five-stage detector was optimized through simulations based on the geant4 detector simulation toolkit, and the fabricated prototype was calibrated in water-equivalent millimeters with 200 MeV protons in the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center. A special polystyrene step phantom was designed and built to speed up and simplify the calibration procedure. The calibrated five-stage detector was tested in the 200 MeV proton beam as part of the pCT head scanner, using a water phantom and polystyrene slabs to verify the WEPL reconstruction accuracy. Results: The beam-test results demonstrated excellent performance of the new detector, in good agreement with the simulation results. The WEPL measurement accuracy is about 3.0 mm per proton in the 0–260 mm WEPL range required for a pCT head scan with a 200 MeV proton beam. Conclusions: The new multistage design approach to WEPL measurements for proton CT and radiography has been prototyped and tested. The test results show that the design is competitive with much more expensive calorimeter and range-counter designs. PMID:26843230

  6. Removing Distortion of Periapical Radiographs in Dental Digital Radiography Using Embedded Markers in an External frame

    PubMed Central

    Kafieh, Rahele; Shahamoradi, Mahdi; Hekmatian, Ehsan; Foroohandeh, Mehrdad; Emamidoost, Mostafa

    2012-01-01

    To carry out in vivo and in vitro comparative pilot study to evaluate the preciseness of a newly proposed digital dental radiography setup. This setup was based on markers placed on an external frame to eliminate the measurement errors due to incorrect geometry in relative positioning of cone, teeth and the sensor. Five patients with previous panoramic images were selected to undergo the proposed periapical digital imaging for in vivo phase. For in vitro phase, 40 extracted teeth were replanted in dry mandibular sockets and periapical digital images were prepared. The standard reference for real scales of the teeth were obtained through extracted teeth measurements for in vitro application and were calculated through panoramic imaging for in vivo phases. The proposed image processing thechnique was applied on periapical digital images to distinguish the incorrect geometry. The recognized error was inversely applied on the image and the modified images were compared to the correct values. The measurement findings after the distortion removal were compared to our gold standards (results of panoramic imaging or measurements from extracted teeth) and showed the accuracy of 96.45% through in vivo examinations and 96.0% through in vitro tests. The proposed distortion removal method is perfectly able to identify the possible inaccurate geometry during image acquisition and is capable of applying the inverse transform to the distorted radiograph to obtain the correctly modified image. This can be really helpful in applications like root canal therapy, implant surgical procedures and digital subtraction radiography, which are essentially dependent on precise measurements. PMID:23724372

  7. Detectability of regional lung ventilation with flat-panel detector-based dynamic radiography.

    PubMed

    Tanaka, Rie; Sanada, Shigeru; Okazaki, Nobuo; Kobayashi, Takeshi; Suzuki, Masayuki; Matsui, Takeshi; Matsui, Osamu

    2008-03-01

    This study was performed to investigate the ability of breathing chest radiography using flat-panel detector (FPD) to quantify relative local ventilation. Dynamic chest radiographs during respiration were obtained using a modified FPD system. Imaging was performed in three different positions, ie, standing and right and left decubitus positions, to change the distribution of local ventilation. We measured the average pixel value in the local lung area. Subsequently, the interframe differences, as well as difference values between maximum inspiratory and expiratory phases, were calculated. The results were visualized as images in the form of a color display to show more or less x-ray translucency. Temporal changes and spatial distribution of the results were then compared to lung physiology. In the results, the average pixel value in each lung was associated with respiratory phase. In all positions, respiratory changes of pixel value in the lower area were greater than those in the upper area (P < 0.01), which was the same tendency as the regional differences in ventilation determined by respiratory physiology. In addition, in the decubitus position, it was observed that areas with large respiratory changes in pixel value moved up in the vertical direction during expiration, which was considered to be airway closure. In conclusion, breathing chest radiography using FPD was shown to be capable of quantifying relative ventilation in local lung area and detecting regional differences in ventilation and timing of airway closure. This method is expected to be useful as a new diagnostic imaging modality for evaluating relative local ventilation.

  8. Right upper quadrant abdominal pain as the initial presentation of polyarteritis nodosa.

    PubMed

    Gago, Ricardo; Shum, Lee Ming; Vilá, Luis M

    2017-02-22

    Polyarteritis nodosa (PAN) is a necrotising vasculitis that involves medium and small vessels. PAN generally presents with constitutional, cutaneous, neurological, renal and gastrointestinal manifestations. However, PAN initially involving a single organ/system is uncommon. Here, we present a 42-year-old man who was hospitalised because of severe right upper quadrant abdominal pain that started 2 months before. Physical examination was remarkable for right upper quadrant abdominal tenderness. Abdominopelvic CT showed lymphadenopathy but no hepatic, gallbladder, pancreatic, intestinal or renal abnormalities. Abdominal angiography showed multiple small aneurysms located in the jejunal and hepatic arteries characteristic of PAN. He had a prompt and remarkable response to high-dose corticosteroids and oral cyclophosphamide. Our case, together with other reports, suggests that PAN should be considered in patients presenting with right upper abdominal pain. Timely diagnosis and treatment reduce the overall morbidity and mortality of the disease.

  9. Effects of lumbopelvic sling and abdominal drawing-in exercises on lung capacity in healthy adults.

    PubMed

    Kim, Myoung-Kwon; Cha, Hyun-Gyu; Shin, Young-Jun

    2016-08-01

    [Purpose] To examine the effects of lumbopelvic sling and abdominal drawing-in exercises on the lung capacities of healthy subjects. [Subjects and Methods] Twenty-nine healthy subjects with no orthopedic history of the back were recruited. Subjects were randomly assigned to a experimental group and control group. Subjects were allocated to one of two groups; an experimental group that underwent lumbopelvic sling and abdominal drawing-in exercises and a control group that underwent treadmill and abdominal drawing-in exercises. Lung capacities were evaluated 4 weeks after exercises. [Results] The experimental group showed significant increments in EV, ERV, IRV, VT vs. pre-intervention results, and the control group showed significant increments in the EVC and IRV. Significant intergroup differences were observed in terms of post-training gains in EVC, IRV, and VT. [Conclusion] Combined application of lumbopelvic sling and abdominal drawing-in exercises were found to have a positive effect on lung capacity.

  10. Effects of lumbopelvic sling and abdominal drawing-in exercises on lung capacity in healthy adults

    PubMed Central

    Kim, Myoung-Kwon; Cha, Hyun-Gyu; Shin, Young-Jun

    2016-01-01

    [Purpose] To examine the effects of lumbopelvic sling and abdominal drawing-in exercises on the lung capacities of healthy subjects. [Subjects and Methods] Twenty-nine healthy subjects with no orthopedic history of the back were recruited. Subjects were randomly assigned to a experimental group and control group. Subjects were allocated to one of two groups; an experimental group that underwent lumbopelvic sling and abdominal drawing-in exercises and a control group that underwent treadmill and abdominal drawing-in exercises. Lung capacities were evaluated 4 weeks after exercises. [Results] The experimental group showed significant increments in EV, ERV, IRV, VT vs. pre-intervention results, and the control group showed significant increments in the EVC and IRV. Significant intergroup differences were observed in terms of post-training gains in EVC, IRV, and VT. [Conclusion] Combined application of lumbopelvic sling and abdominal drawing-in exercises were found to have a positive effect on lung capacity. PMID:27630393

  11. Television Quiz Show Simulation

    ERIC Educational Resources Information Center

    Hill, Jonnie Lynn

    2007-01-01

    This article explores the simulation of four television quiz shows for students in China studying English as a foreign language (EFL). It discusses the adaptation and implementation of television quiz shows and how the students reacted to them.

  12. Factors associated with abdominal obesity in children

    PubMed Central

    Melzer, Matheus Ribeiro Theodósio Fernandes; Magrini, Isabella Mastrangi; Domene, Semíramis Martins Álvares; Martins, Paula Andrea

    2015-01-01

    Objective: To identify the association of dietary, socioeconomic factors, sedentary behaviors and maternal nutritional status with abdominal obesity in children. Methods: A cross-sectional study with household-based survey, in 36 randomly selected census tracts in the city of Santos, SP. 357 families were interviewed and questionnaires and anthropometric measurements were applied in mothers and their 3-10 years-old children. Assessment of abdominal obesity was made by maternal and child's waist circumference measurement; for classification used cut-off points proposed by World Health Organization (1998) and Taylor et al. (2000) were applied. The association between variables was performed by multiple logistic regression analysis. Results: 30.5% of children had abdominal obesity. Associations with children's and maternal nutritional status and high socioeconomic status were shown in the univariate analysis. In the regression model, children's body mass index for age (OR=93.7; 95%CI 39.3-223.3), female gender (OR=4.1; 95%CI 1.8-9.3) and maternal abdominal obesity (OR=2.7; 95%CI 1.2-6.0) were significantly associated with children's abdominal obesity, regardless of the socioeconomic status. Conclusions: Abdominal obesity in children seems to be associated with maternal nutritional status, other indicators of their own nutritional status and female gender. Intervention programs for control of childhood obesity and prevention of metabolic syndrome should consider the interaction of the nutritional status of mothers and their children. PMID:26298655

  13. Abdominal aortic aneurysm: A comprehensive review

    PubMed Central

    Aggarwal, Sourabh; Qamar, Arman; Sharma, Vishal; Sharma, Alka

    2011-01-01

    An arterial aneurysm is defined as a focal dilation of a blood vessel with respect to the original artery. The risk of abdominal aortic aneurysms (AAAs) increases dramatically in the presence of the following factors: age older than 60 years, smoking, hypertension and Caucasian ethnicity. The likelihood that an aneurysm will rupture is influenced by the aneurysm size, expansion rate, continued smoking and persistent hypertension. The majority of AAAs are asymptomatic and are detected as an incidental finding on ultrasonography, abdominal computed tomography or magnetic resonance imaging performed for other purposes. It can also present with abdominal pain or complications such as thrombosis, embolization and rupture. Approximately 30% of asymptomatic AAAs are discovered as a pulsatile abdominal mass on routine physical examination. Abdominal ultrasonography is considered the screening modality of choice for detecting AAAs because of its high sensitivity and specificity, as well as its safety and relatively lower cost. The decision to screen for AAAs is challenging. The United States Preventive Services Task Force recommended that men between the age of 65 to 75 years who have ever smoked should be screened at least once for AAAs by abdominal ultrasonography. Management options for patients with an asymptomatic AAA include reduction of risk factors such as smoking, hypertension and dyslipidemia; medical therapy with beta-blockers; watchful waiting; endovascular stenting; and surgical repair depending on the size and expansion rate of the aneurysm and underlying comorbidities. PMID:21523201

  14. Reconstruction of abdominal wall musculofascial defects with small intestinal submucosa scaffolds seeded with tenocytes in rats.

    PubMed

    Song, Zhicheng; Peng, Zhiyou; Liu, Zhengni; Yang, Jianjun; Tang, Rui; Gu, Yan

    2013-07-01

    The repair of abdominal wall defects following surgery remains a difficult challenge. Although multiple methods have been described to restore the integrity of the abdominal wall, there is no clear consensus on the ideal material for reconstruction. This study explored the feasibility of in vivo reconstruction of a rat model of an abdominal wall defect with a composite scaffold of tenocytes and porcine small intestinal submucosa (SIS). In the current study, we created a 2×1.5 cm abdominal wall defect in the anterolateral abdominal wall of Sprague-Dawley rats, which were assigned into three groups: the cell-SIS construct group, the cell-free SIS scaffold group, and the abdominal wall defect group. Tenocytes were obtained from the tendons of rat limbs. After isolation and expansion, cells (2×10(7)/mL) were seeded onto the three-layer SIS scaffolds and cultured in vitro for 5 days. Cell-SIS constructs or cell-free constructs were implanted to repair the abdominal wall defects. The results showed that the tenocytes could grow on the SIS scaffold and secreted corresponding matrices. In addition, both scaffolds could repair the abdominal wall defects with no hernia recurrence. In comparison to the cell-free SIS scaffold, the composite scaffold exhibited increased vascular regeneration and mechanical strength. Furthermore, following increased time in vivo, the mechanical strength of the composite scaffold became stronger. The results indicate that the composite scaffold can provide increased mechanical strength that may be suitable for repairing abdominal wall defects.

  15. [The computed tomographic diagnosis of inflammatory abdominal aortic aneurysms].

    PubMed

    Koch, J A; Grützner, G; Jungblut, R M; Kniemeyer, H W; Mödder, U

    1994-07-01

    Amongst 1599 patients undergoing surgery for abdominal aortic aneurysm, there were 89 patients (5.6%) who showed typical features of inflammatory aneurysms of the abdominal aorta (IAAA). 37 of the 89 patients had been examined preoperatively by CT. In 73% of the cases (27/37) a correct diagnosis had been made. Localisation, width and extent of the IAAA was correctly diagnosed in all patients. Involvement of the renal arteries by the inflammatory process, the extent of thrombus and of mural calcification were accurately shown. The inflammatory tissues were typically ventral and lateral to the aorta. Frequently, there were adhesions to neighbouring structures. Aortic rupture, aortic dissection and retroperitoneal lymphoma may produce similar CT appearances; nevertheless, CT remains at present the method of choice for the diagnosis of IAAA because of its high sensitivity.

  16. [Migration of an epicardial pacemaker into the abdominal cavity].

    PubMed

    Barabás, János Imre; Hüttl, Tivadar; Hartyánszky, István; Fazekas, Levente; Oláh, Zoltán; Zima, Endre; Paulovich, Erzsébet; Kőszegi, Andrea; Szabolcs, Zoltán

    2015-01-25

    Migration of a permanent pacemaker generator from their intramuscular pocket to the abdominal cavity is a less frequent, but potentially life-threatening complication. The authors present the case of a 69-year-old woman, who visited the emergency department of the clinic, with complains of non-specific abdominal symptoms. Her past medical history included a complete atrioventricular block diagnosed in 2009 during the mitral valve replacement and since then she had an epicardial permanent pacemaker; the pulse generator was placed into an intramuscular pouch created in the left subcostal region. Surprisingly, radiologic examinations showed that the generator migrated into the pouch of Douglas. Considering patient safety, first a new intracardiac pacemaker was implanted and then the migrated device was removed surgically. The patient was discharged on the seventh postoperative day.

  17. Early laparoscopic approach to pancreatic injury following blunt abdominal trauma.

    PubMed

    Vijay, Adarsh; Abdelrahman, Husham; El-Menyar, Ayman; Al-Thani, Hassan

    2014-12-04

    The incidence of pancreatic injury following blunt abdominal trauma is rare. A timely accurate diagnosis of such injury is difficult and also the management remains controversial. Here, we reported the successful use of laparoscopy to diagnose, characterize and treat blunt pancreatic trauma in a 28-year-old male patient involved in a motor vehicle crash. An abdominal computed tomography scan showed peripancreatic fat stranding suggestive of pancreatic injury. With persistent clinical signs of peritonitis and laboratory investigations suggestive of pancreatitis, the patient underwent laparoscopic drainage of the lesser sac. The patient had an uneventful postoperative course. The management of patients with blunt pancreatic injuries should be tailored to individual situations. Our experience suggests that a timely laparoscopic management of traumatic pancreatic injury is safe approach in selected cases.

  18. Lipoprotein alterations, abdominal fat distribution and breast cancer.

    PubMed

    Schreier, L E; Berg, G A; Basilio, F M; Lopez, G I; Etkin, A E; Wikinski, R L

    1999-04-01

    Plasma lipid profile and abdominal obesity have been associated with breast cancer risk, however published results have been inconsistent. To clarify these associations we studied lipid and lipoprotein alterations, obesity degree and body fat distribution, in 30 newly diagnosed breast cancer patients without treatment and 30 controls matched by age and menopausal status. Both pre and postmenopausal breast cancer patients presented higher body mass index, waist/hip ratio and insulin levels than their matched controls. An increase in triglycerides and a decrease in HDL-cholesterol, especially in the HDL2 subfraction, were observed in patients with breast cancer. Besides, HDL particle from these patients showed increased apo A1/HDL-cholesterol ratio. These alterations were correlated with waist/hip ratio. The association between lipoprotein alterations and abdominal obesity independent of menopausal status, in untreated newly diagnosed breast cancer patients is reported for the first time in this study.

  19. Imperforate hymen: a cause of abdominal pain in female adolescents

    PubMed Central

    Lardenoije, Céline; Aardenburg, Robert; Mertens, Helen

    2009-01-01

    A 16-year-old girl presented with primary amenorrhea and had had cyclical abdominal pain for almost a year. At examination we observed a painful mass in the lower abdomen and normal secondary sex characteristics. Perineal examination showed a bluish bulging hymen. Transabdominal ultrasonography revealed a dense mass in the pelvis measuring about 12×11 cm. We diagnosed an imperforate hymen with haematocolpos and haematometra. The hymen was opened surgically and a large quantity of menstrual blood was drained from the vagina and uterus. Postoperative recovery was normal without any pain. The patient now menstruates regularly. An imperforate hymen occurs in 0.05% of women. It is important to be aware of this while examining a female adolescent presenting with cyclical abdominal pain and primary amenorrhea. Late discovery of an imperforate hymen may lead to pain, infections, hydronephrosis and endometriosis with subfertility as a possible consequence. PMID:21686660

  20. Effect of craniocervical posture on abdominal muscle activities

    PubMed Central

    Su, Jung Gil; Won, Shin Ji; Gak, Hwangbo

    2016-01-01

    [Purpose] The aim of this study was to investigate the influence of the craniocervical posture on abdominal muscle activities in hook-lying position. [Subjects] This study recruited 12 healthy young adults. [Methods] Each subject was asked to adopt a supine position with the hip and knee flexed at 60°. Surface electromyographic signals of transversus abdominis/internal oblique, rectus abdominis, and external oblique in different craniocervical postures (extension, neutral, and flexion) were compared. [Results] The transversus abdominis and rectus abdominis showed increased muscle activities in craniocervical flexion compared to craniocervical extension and neutral position. Greater muscle activities of the external oblique were seen in craniocervical flexion than in craniocervical extension. [Conclusion] Craniocervical flexion was found to be effective to increase the abdominal muscle activities. Consideration of craniocervical posture is recommended when performing trunk stabilization exercises. PMID:27065558

  1. Practical guidelines for radiographers to improve computed radiography image quality.

    PubMed

    Pongnapang, N

    2005-10-01

    Computed Radiography (CR) has become a major digital imaging modality in a modern radiological department. CR system changes workflow from the conventional way of using film/screen by employing photostimulable phosphor plate technology. This results in the changing perspectives of technical, artefacts and quality control issues in radiology departments. Guidelines for better image quality in digital medical enterprise include professional guidelines for users and the quality control programme specifically designed to serve the best quality of clinical images. Radiographers who understand technological shift of the CR from conventional method can employ optimization of CR images. Proper anatomic collimation and exposure techniques for each radiographic projection are crucial steps in producing quality digital images. Matching image processing with specific anatomy is also important factor that radiographers should realise. Successful shift from conventional to fully digitised radiology department requires skilful radiographers who utilise the technology and a successful quality control program from teamwork in the department.

  2. Inspection of an artificial heart by the neutron radiography technique

    NASA Astrophysics Data System (ADS)

    Pugliesi, R.; Geraldo, L. P.; Andrade, M. L. G.; Menezes, M. O.,; Pereira, M. A. S.; Maizato, M. J. S.

    1999-11-01

    The neutron radiography technique was employed to inspect an artificial heart prototype which is being developed to provide blood circulation for patients expecting heart transplant surgery. The radiographs have been obtained by the direct method with a gadolinium converter screen along with the double coated Kodak-AA emulsion film. The artificial heart consists of a flexible plastic membrane located inside a welded metallic cavity, which is employed for blood pumping purposes. The main objective of the present inspection was to identify possible damages in this plastic membrane, produced during the welding process of the metallic cavity. The obtained radiographs were digitized as well as analysed in a PC and the improved images clearly identify several damages in the plastic membrane, suggesting changes in the welding process.

  3. [Information technologies for scanning X-ray radiography].

    PubMed

    Kretov, V V; Ukraintsev, Iu G

    2005-01-01

    Digital technologies have been widely used in X-rays diagnostics, including computer tomography, magnetic-resonance tomography, digital radiography etc. Digital technologies for image analysis essentially change all arrangements and procedures of preventive examinations made at patient-care facilities. As for digital fluorography, the basic principles of fluorography diagnostic room are standard but for one arrangement-the unit is controlled via a computer-assisted working place (CAWP) by the radiologist assistant; the room of radiologist is also equipped with CAWP. Admittedly, a key issue in general fluorographic examinations is registration of patients and preparation of them for the procedure. Contemplated in the paper are new potentialities of digital fluorography of big number of patients by low-dose fluorography (LDF, equipment manufacturer/Orel, Russia) which enhance the rate and quality of diagnostics.

  4. Dosimetry and image quality assessment in a direct radiography system

    PubMed Central

    Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2014-01-01

    Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119

  5. Measurement Of Gas Bubbles In Mercury Using Proton Radiography

    SciTech Connect

    Riemer, Bernie; Bingham, Philip R; Mariam, Fesseha G; Merrill, Frank E

    2007-01-01

    An experiment using proton radiography on a small mercury loop for testing gas bubble injection was conducted at the Los Alamos Neutron Science Center (LANSCE) in December 2006. Small gas bubble injection is one of the approaches under development to reduce cavitation damage in the U.S. Spallation Neutron Source mercury target vessel. Several hundred radiograph images were obtained as the test loop was operated over range of conditions that included two jet type bubble generators, two needle type bubble generators, various mercury flow speeds and gas injection rates, and use of helium, argon and xenon. This paper will describe the analysis of the radiograph images and present the obtained bubble measurement data.

  6. Reduction of absorbed doses in radiography of the facial skeleton

    SciTech Connect

    Julin, P.; Kraepelien, T.

    1984-11-01

    Radiation absorbed doses from radiography of the paranasal sinuses and the facial skeleton were measured with thermoluminescent dosimeters (TLD) on a phantom head using high-sensitivity screens in an Orbix stand. The entrance doses to the skin of the head ranged from 0.31 to 2.9 mGy per exposure. The absorbed dose from a full series of sinus exposures averaged 0.33 mGy for the oral mucous membrane, 0.33 mGy for the maxillary sinus mucous membrane, 0.11 MgY for the parotid gland, 0.15 MgY for the submandibular gland, 0.61 mGy for the eye lens, and 0.75 mGy for the thyroid gland region. A leaded soft collar adapted to the thyroid region reduced the thyroid doses by more than one order of magnitude, but also reduced the image field.

  7. Digital neutron radiography using plane converters with multiwire proportional chambers

    SciTech Connect

    Kaplan, S.N.; Director, B.A.; Perez-Mendez, V.; Valentine, K.H.

    1981-12-01

    The work described here was completed more than three years ago, and represents, in large part the PhD and MS thesis research of two of the present authors. Much of it has been reported previously elsewhere. It constitutes an effort to develop and study a moderately low cost, moderate resolution, high sensitivity, on-line method for digital neutron radiography, intended for use where neutron fluence was limited by source strength, or received dose. The basic imaging system consisted of a position-sensitive gas proportional chamber together with its associated imaging electronics, and a plane neutron converter. Enriched-boron, gadolinium, and polyethylene (for fast neutrons) converters were analyzed and tested. Some work was done on digital data enhancement, and efforts to improve spatial resolution included pressurizing the proportional-chamber gas to reduce the track lengths of the neutron-interaction products.

  8. A third generation mobile high energy radiography system

    SciTech Connect

    Fry, D.A.; Valdez, J.E.; Johnson, C.S.; Kimerly, H.J.; Vananne, J.R.

    1997-12-01

    A third generation mobile high energy radiographic capability has been completed and put into service by the Los Alamos National Laboratory. The system includes a 6 MeV linac x-ray generator, Co-60 gamma source, all-terrain transportation, on-board power, real-time radiography (RTR), a control center, and a complete darkroom capability. The latest version includes upgraded and enhanced portability, flexibility, all-terrain operation, all-weather operation, and ease of use features learned from experience with the first and second generation systems. All systems were required to have the following characteristics; all-terrain, all-weather operation, self-powered, USAF airlift compatible, reliable, simple to setup, easy to operate, and all components two-person portable. The systems have met these characteristics to differing degrees, as is discussed in the following section, with the latest system being the most capable.

  9. Wrist rhythm during wrist joint motion evaluated by dynamic radiography.

    PubMed

    Kawashima, Hiroki; Tada, Kaoru; Suganuma, Seigo; Tsuchiya, Hiroyuki; Sanada, Shigeru

    2014-01-01

    We hypothesized that wrist joint motion involves a "wrist rhythm" similar to the scapulohumeral rhythm. Therefore, we used a flat-panel detector to evaluate the ratio of radiolunate and capitolunate joint motions during wrist joint motion by dynamic radiography. The subjects were 20 healthy men. Dynamic imaging of the wrist joint was performed during active exercise for a total of ten seconds. In this study, we defined the radiocarpal (RL angle) and midcarpal joint angle (CL angle) as the wrist joint angle in the obtained images and measured the variation of these angles. The average curve was plotted and regression lines calculated from the average curve. The ratio was calculated from the slopes of the regression lines of the RL CL angles. These findings indicated that the ratio of the RL and CL angle motions was approximately 1:4 during palmar flexion and approximately 2:1 during dorsiflexion.

  10. MR Fingerprinting for Rapid Quantitative Abdominal Imaging

    PubMed Central

    Chen, Yong; Jiang, Yun; Pahwa, Shivani; Ma, Dan; Lu, Lan; Twieg, Michael D.; Wright, Katherine L.; Seiberlich, Nicole; Griswold, Mark A.

    2016-01-01

    Purpose To develop a magnetic resonance (MR) “fingerprinting” technique for quantitative abdominal imaging. Materials and Methods This HIPAA-compliant study had institutional review board approval, and informed consent was obtained from all subjects. To achieve accurate quantification in the presence of marked B0 and B1 field inhomogeneities, the MR fingerprinting framework was extended by using a two-dimensional fast imaging with steady-state free precession, or FISP, acquisition and a Bloch-Siegert B1 mapping method. The accuracy of the proposed technique was validated by using agarose phantoms. Quantitative measurements were performed in eight asymptomatic subjects and in six patients with 20 focal liver lesions. A two-tailed Student t test was used to compare the T1 and T2 results in metastatic adenocarcinoma with those in surrounding liver parenchyma and healthy subjects. Results Phantom experiments showed good agreement with standard methods in T1 and T2 after B1 correction. In vivo studies demonstrated that quantitative T1, T2, and B1 maps can be acquired within a breath hold of approximately 19 seconds. T1 and T2 measurements were compatible with those in the literature. Representative values included the following: liver, 745 msec ± 65 (standard deviation) and 31 msec ± 6; renal medulla, 1702 msec ± 205 and 60 msec ± 21; renal cortex, 1314 msec ± 77 and 47 msec ± 10; spleen, 1232 msec ± 92 and 60 msec ± 19; skeletal muscle, 1100 msec ± 59 and 44 msec ± 9; and fat, 253 msec ± 42 and 77 msec ± 16, respectively. T1 and T2 in metastatic adenocarcinoma were 1673 msec ± 331 and 43 msec ± 13, respectively, significantly different from surrounding liver parenchyma relaxation times of 840 msec ± 113 and 28 msec ± 3 (P < .0001 and P < .01) and those in hepatic parenchyma in healthy volunteers (745 msec ± 65 and 31 msec ± 6, P < .0001 and P = .021, respectively). Conclusion A rapid technique for quantitative abdominal imaging was developed that

  11. Plasma-flash radiography utilizing a molybdenum target in dentistry

    NASA Astrophysics Data System (ADS)

    Yamamoto, Mariko; Takabe, Akihito; Sakamaki, Kimio; Sato, Eiichi; Takahashi, Kei; Sagae, Michiaki; Oizumi, Teiji; Hayasi, Yasuomi; Sasaki, Katsuaki; Tamakawa, Yoshiharu; Yanagisawa, Toru

    1995-09-01

    The construction and the radiographic characteristics of a plasma flash x-ray generator having a molybdenum-target (anode tip) triode are described. This generator was primarily designed in order to perform soft radiography in dental medicine and employed the following essential components: a high-voltage power supply, a low-impedance coaxial transmission line with a gap switch, a coaxial oil condenser of 0.2 (mu) F, a turbo-molecular pump, a Krytron pulser as a trigger device, and a flash x-ray tube. The high-voltage main condenser of 0.2 (mu) F was charged from 40 to 60 kV by the power supply, and the electric charges in the condenser were discharged to the tube after closing the gap switch. Because this tube employed a long target, the plasma x-ray source which consists of molybdenum ions and electrons was easily produced by the target evaporating. The maximum tube voltage was nearly equivalent to the initial charge voltage of the main condenser, and the maximum current had a value of about 25 kA with a charging voltage of 60 kV. The average width of flash x rays was less than 1 microsecond(s) , and the time-integrated x-ray intensity with a charging voltage of 60 kV was approximately 20 (mu) C/kg at 1.0 m per pulse. The characteristic K-series intensity substantially increased according to increases in the charged voltage. High-speed dental radiography was performed using a laser timing switch and a trigger-delay device.

  12. Paediatric entrance doses from exposure index in computed radiography

    NASA Astrophysics Data System (ADS)

    Vano, E.; Martinez, D.; Fernandez, J. M.; Ordiales, J. M.; Prieto, C.; Floriano, A.; Ten, J. I.

    2008-06-01

    Over the last two years we have evaluated paediatric patient doses in projection radiography derived from exposure level (EL) in computed radiography (CR) in a large university hospital. Entrance surface air kerma (ESAK) for 3501 paediatric examinations was calculated from the EL, which is a dose index parameter related to the light emitted by the phosphor-stimulable plate, archived in the Digital Imaging and Communications in Medicine (DICOM) header of the images and automatically transferred to a database using custom-built dedicated software. Typical mean thicknesses for several age bands of paediatric patients was estimated to calculate ESAK from the EL values, using results of experimental measurements with phantoms for the typical x-ray beam qualities used in paediatric examinations. Mean/median ESAK values (in µGy) for the age bands of <1 year, 1-5 years, 6-10 years and 11-15 years have been obtained for chest without a bucky: 51/41, 57/34, 91/54 and 122/109; chest with a bucky (for only the last three age bands): 114/87, 129/105 and 219/170; abdomen: 119/91, 291/225, 756/600 and 1960/1508 and pelvis: 65/48, 455/314, 943/707 and 2261/1595. Sample sizes of clinical images used for the (indirect) measurements were 1724 for chest without a bucky, 799 for chest with a bucky, 337 for abdomen and 641 for pelvis. The methodology we describe could be applicable to other centres using CR as an imaging modality for paediatrics. Presently, this method is the only practical approach to automatically extract parameters contained in the DICOM header, for the calculation of patient dose values for the CR modality.

  13. Single-exposure dual-energy computed radiography.

    PubMed

    Stewart, B K; Huang, H K

    1990-01-01

    This paper focuses on analysis and development of a single-exposure dual-energy digital radiographic method using computed radiography (Fuji FCR-101 storage phosphor system). A detector sandwich consisting of storage phosphor imaging plates and an interdetector filter is used. The goal of this process is to provide a simple dual-energy method using typical plane-projection radiographic equipment and techniques. This approach exploits the transparency of the storage phosphor plates, using radiographic information that would be otherwise lost, to provide energy selective information essentially as a by-product of the radiographic examination. In order to effectively make use of the large dynamic range of the storage phosphor imaging plates (10,000:1), a computed radiography image reading mode of fixed analog-to-digital converter gain and variable photomultiplier sensitivity provides image data which can be related to relative incident exposure for export to the decomposition algorithm. Scatter rejection requirements necessitated crossed 12:1 grids for a field size of 36 x 36 cm. Optimal technique parameters obtained from computer simulation through minimization of the aluminum and Plexiglas equivalent image uncertainty under conditions of constant absorbed does resulted as: 100 kVp using a 0.15-mm-thick tin (Sn) interdetector filter for the lung field. This yields a surface exposure of 23 mR and a surface absorbed dose of 0.26 mGy for a 23-cm-thick chest. Clinical application in evaluation of the solitary pulmonary nodule is discussed, along with an image set demonstrating this application.

  14. Plasma-flash radiography utilizing a molybdenum target in dentistry

    SciTech Connect

    Yamamoto, Mariko; Takabe, Akihito; Sakamaki, Kimio

    1995-12-31

    The construction and the radiographic characteristics of a plasma flash x-ray generator having a molybdenum-target (anode tip) triode are described. This generator was primarily designed in order to perform soft radiography in dental medicine and employed the following essential components: a high-voltage power supply, a low-impedance coaxial transmission line with a gap switch, a coaxial oil condenser of 0.2 {micro}F, a turbo-molecular pump, a Krytron pulser as a trigger device, and a flash x-ray tube. The high-voltage main condenser of 0.2 {micro}F was charged from 40 to 60 kV by the power supply, and the electric charges in the condenser were discharged to the tube after closing the gap switch. Because this tube employed a long target, the plasma x-ray source which consists of molybdenum ions and electrons was easily produced by the target evaporating. The maximum tube voltage was nearly equivalent to the initial charging voltage of the main condenser, and the maximum current had a value of about 25 kA with a charging voltage of 60 kV. The average width of flash x rays was less than 1 {micro}s, and the time-integrated x-ray intensity with a charging voltage of 60 kV was approximately 20 {micro}C/kg at 1.0 m per pulse. The characteristic K-series intensity substantially increased according to increases in the charging voltage. High-speed dental radiography was performed by using a laser timing switch and a trigger-delay device.

  15. Modulation of yellow expression contributes to thermal plasticity of female abdominal pigmentation in Drosophila melanogaster

    PubMed Central

    Gibert, Jean-Michel; Mouchel-Vielh, Emmanuèle; Peronnet, Frédérique

    2017-01-01

    Phenotypic plasticity describes the ability of a given genotype to produce distinct phenotypes in different environments. We use the temperature sensitivity of abdominal pigmentation in Drosophila melanogaster females as a model to analyse the effect of the environment on development. We reported previously that thermal plasticity of abdominal pigmentation in females involves the pigmentation gene tan (t). However, the expression of the pigmentation gene yellow (y) was also modulated by temperature in the abdominal epidermis of pharate females. We investigate here the contribution of y to female abdominal pigmentation plasticity. First, we show that y is required for the production of black Dopamine-melanin. Then, using in situ hybridization, we show that the expression of y is strongly modulated by temperature in the abdominal epidermis of pharate females but not in bristles. Interestingly, these two expression patterns are known to be controlled by distinct enhancers. However, the activity of the y-wing-body epidermal enhancer only partially mediates the effect of temperature suggesting that additional regulatory sequences are involved. In addition, we show that y and t co-expression is needed to induce strong black pigmentation indicating that y contributes to female abdominal pigmentation plasticity. PMID:28230190

  16. Monocytes and macrophages in abdominal aortic aneurysm.

    PubMed

    Raffort, Juliette; Lareyre, Fabien; Clément, Marc; Hassen-Khodja, Réda; Chinetti, Giulia; Mallat, Ziad

    2017-04-13

    Abdominal aortic aneurysm (AAA) is a life-threatening disease associated with high morbidity, and high mortality in the event of aortic rupture. Major advances in open surgical and endovascular repair of AAA have been achieved during the past 2 decades. However, drug-based therapies are still lacking, highlighting a real need for better understanding of the molecular and cellular mechanisms involved in AAA formation and progression. The main pathological features of AAA include extracellular matrix remodelling associated with degeneration and loss of vascular smooth muscle cells and accumulation and activation of inflammatory cells. The inflammatory process has a crucial role in AAA and substantially influences many determinants of aortic wall remodelling. In this Review, we focus specifically on the involvement of monocytes and macrophages, summarizing current knowledge on the roles, origin, and functions of these cells in AAA development and its complications. Furthermore, we show and propose that distinct monocyte and macrophage subsets have critical and differential roles in initiation, progression, and healing of the aneurysmal process. On the basis of experimental and clinical studies, we review potential translational applications to detect, assess, and image macrophage subsets in AAA, and discuss the relevance of these applications for clinical practice.

  17. Pulsatile blood flow in Abdominal Aortic Aneurysms

    NASA Astrophysics Data System (ADS)

    Salsac, Anne-Virginie; Lasheras, Juan C.; Singel, Soeren; Varga, Chris

    2001-11-01

    We discuss the results of combined in-vitro laboratory measurements and clinical observations aimed at determining the effect that the unsteady wall shear stresses and the pressure may have on the growth and eventual rupturing of an Abdominal Aortic Aneurysm (AAA), a permanent bulging-like dilatation occurring near the aortic bifurcation. In recent years, new non-invasive techniques, such as stenting, have been used to treat these AAAs. However, the development of these implants, aimed at stopping the growth of the aneurysm, has been hampered by the lack of understanding of the effect that the hemodynamic forces have on the growth mechanism. Since current in-vivo measuring techniques lack the precision and the necessary resolution, we have performed measurements of the pressure and shear stresses in laboratory models. The models of the AAA were obtained from high resolution three-dimensional CAT/SCANS performed in patients at early stages of the disease. Preliminary DPIV measurements show that the pulsatile blood flow discharging into the cavity of the aneurysm leads to large spikes of pressure and wall shear stresses near and around its distal end, indicating a possible correlation between the regions of high wall shear stresses and the observed location of the growth of the aneurysm.

  18. Reconstruction of complex abdominal wall defects.

    PubMed

    Leppäniemi, A; Tukiainen, E

    2013-01-01

    Complex abdominal wall defects refer to situations where simple ventral hernia repair is not feasible because the defect is very large, there is a concomitant infection or failed previous re-pair attempt, or if there is not enough original skin to cover the repair. Usually a complex abdominal wall repair is preceded by a period of temporary abdominal closure where the short-term aims include closure of the catabolic drain, protection of the viscera and preventing fistula formation, preventing bowel adherence to the abdominal wall, and enabling future fascial and skin closure. Currently the best way to achieve these goals is the vacuum- and mesh-mediated fascial traction method achieving close to 90% fascial closure rates. The long-term aims of an abdominal closure following a planned hernia strategy include intact skin cover, fascial closure at midline (if possible), good functional outcome with innervated abdominal musculature, no pain and good cosmetic result. The main methods of abdominal wall reconstruction include the use of prosthetic (mesh) or autologous material (tissue flaps). In patients with original skin cover over the fascial defect (simple ventral hernia), the most commonly used method is hernia repair with an artificial mesh. For more complex defects, our first choice of reconstruction is the component separation technique, sometimes combined with a mesh. In contaminated fields where component separation alone is not feasible, a combination with a biological mesh can be used. In large defects with grafted skin, a free TFL flap is the best option, sometimes reinforced with a mesh and enhanced with components separation.

  19. The complaints and dietary habits of the patients with gastritis and undefined abdominal pain.

    PubMed

    Harju, E

    1985-02-01

    The complaints and dietary habits of sixteen patients with gastritis and fourteen with undefined abdominal pain were studied by recording method. The results showed that the symptoms of the patients with gastritis and undefined abdominal pain were similar and mostly postprandial and they can be regarded as local (abdominal pain, meteorism, discomfort and heartburn) and/or general (sweating, nausea and faintness). The patients have variations of the symptomatic and asymptomatic periods. The symptomatic patients with gastritis have significantly higher number of daily meals than the asymptomatic patients with gastritis. The daily intake of food, energy and nutrients are low especially in the symptomatic patients with gastritis. It is concluded that the symptoms experienced by the patients with gastritis or undefined abdominal pain are related to the eating so that the daily dietary habits are disturbed. The produced a low intake of food, energy and nutrients especially in the patients with symptomatic gastritis.

  20. Intra-abdominal pressure: an integrative review.

    PubMed

    Milanesi, Rafaela; Caregnato, Rita Catalina Aquino

    2016-01-01

    There is a growing request for measuring intra-abdominal pressure in critically ill patients with acute abdominal pain to be clarified. Summarizing the research results on measurement of vesical intra-abdominal pressure and analyzing the level of evidence were the purposes of this integrative literature review, carried out based on the databases LILACS, MEDLINE and PubMed, from 2005 to July 2012. Twenty articles were identified, in that, 12 literature reviews, 4 descriptive and exploratory studies, 2 expert opinions, one prospective cohort study and one was an experience report. The vesical intra-abdominal pressure measurement was considered gold standard. There are variations in the technique however, but some common points were identified: complete supine position, in absence of abdominal contracture, in the end of expiration and expressed in mmHg. Most research results indicate keeping the transducer zeroed at the level of the mid-axillary line at the iliac crest level, and instill 25mL of sterile saline. Strong evidence must be developed. RESUMO Em pacientes críticos com quadros abdominais agudos a esclarecer é crescente a solicitação da aferição da pressão intra-abdominal. Sintetizar resultados de pesquisas sobre a mensuração da pressão intra-abdominal pela via vesical e analisar o nível de evidência foram os objetivos desta revisão integrativa da literatura, realizada nas bases LILACS, MEDLINE e PubMed, no período de 2005 a julho de 2012. Identificaram-se 20 artigos, sendo 12 revisões de literatura, 4 estudos exploratório-descritivos, 2 opiniões de especialistas, 1 estudo de coorte prospectivo e 1 relato de experiência. O método vesical para mensuração da pressão intra-abdominal foi considerado padrão-ouro. Existem variações na técnica, entretanto pontos em comum foram identificados: posição supina completa, na ausência de contratura abdominal, ao final da expiração e expressa em mmHg. A maioria indica posicionar o ponto zero do

  1. Intra-abdominal pressure: an integrative review

    PubMed Central

    Milanesi, Rafaela; Caregnato, Rita Catalina Aquino

    2016-01-01

    ABSTRACT There is a growing request for measuring intra-abdominal pressure in critically ill patients with acute abdominal pain to be clarified. Summarizing the research results on measurement of vesical intra-abdominal pressure and analyzing the level of evidence were the purposes of this integrative literature review, carried out based on the databases LILACS, MEDLINE and PubMed, from 2005 to July 2012. Twenty articles were identified, in that, 12 literature reviews, 4 descriptive and exploratory studies, 2 expert opinions, one prospective cohort study and one was an experience report. The vesical intra-abdominal pressure measurement was considered gold standard. There are variations in the technique however, but some common points were identified: complete supine position, in absence of abdominal contracture, in the end of expiration and expressed in mmHg. Most research results indicate keeping the transducer zeroed at the level of the mid-axillary line at the iliac crest level, and instill 25mL of sterile saline. Strong evidence must be developed. PMID:26958978

  2. Imaging the Abdominal Manifestations of Cystic Fibrosis

    PubMed Central

    McDermott, S.; Chan, V. O.; Ridge, C. A.

    2017-01-01

    Cystic fibrosis (CF) is a multisystem disease with a range of abdominal manifestations including those involving the liver, pancreas, and kidneys. Recent advances in management of the respiratory complications of the disease has led to a greater life expectancy in patients with CF. Subsequently, there is increasing focus on the impact of abdominal disease on quality of life and survival. Liver cirrhosis is the most important extrapulmonary cause of death in CF, yet significant challenges remain in the diagnosis of CF related liver disease. The capacity to predict those patients at risk of developing cirrhosis remains a significant challenge. We review representative abdominal imaging findings in patients with CF selected from the records of two academic health centres, with a view to increasing familiarity with the abdominal manifestations of the disease. We review their presentation and expected imaging findings, with a focus on the challenges facing diagnosis of the hepatic manifestations of the disease. An increased familiarity with these abdominal manifestations will facilitate timely diagnosis and management, which is paramount to further improving outcomes for patients with cystic fibrosis. PMID:28250993

  3. Functional bowel disorders and functional abdominal pain

    PubMed Central

    Thompson, W; Longstreth, G; Drossman, D; Heaton, K; Irvine, E; Muller-Lissner, S

    1999-01-01

    The Rome diagnostic criteria for the functional bowel disorders and functional abdominal pain are used widely in research and practice. A committee consensus approach, including criticism from multinational expert reviewers, was used to revise the diagnostic criteria and update diagnosis and treatment recommendations, based on research results. The terminology was clarified and the diagnostic criteria and management recommendations were revised. A functional bowel disorder (FBD) is diagnosed by characteristic symptoms for at least 12 weeks during the preceding 12 months in the absence of a structural or biochemical explanation. The irritable bowel syndrome, functional abdominal bloating, functional constipation, and functional diarrhea are distinguished by symptom-based diagnostic criteria. Unspecified FBD lacks criteria for the other FBDs. Diagnostic testing is individualized, depending on patient age, primary symptom characteristics, and other clinical and laboratory features. Functional abdominal pain (FAP) is defined as either the FAP syndrome, which requires at least six months of pain with poor relation to gut function and loss of daily activities, or unspecified FAP, which lacks criteria for the FAP syndrome. An organic cause for the pain must be excluded, but aspects of the patient's pain behavior are of primary importance. Treatment of the FBDs relies upon confident diagnosis, explanation, and reassurance. Diet alteration, drug treatment, and psychotherapy may be beneficial, depending on the symptoms and psychological features.


Keywords: functional bowel disorder; functional constipation; functional diarrhea; irritable bowel syndrome; functional abdominal pain; functional abdominal bloating; Rome II PMID:10457044

  4. Creation of Abdominal Adhesions in Mice.

    PubMed

    Marshall, Clement D; Hu, Michael S; Leavitt, Tripp; Barnes, Leandra A; Cheung, Alexander T M; Malhotra, Samir; Lorenz, H Peter; Longaker, Michael T

    2016-08-27

    Abdominal adhesions consist of fibrotic tissue that forms in the peritoneal space in response to an inflammatory insult, typically surgery or intraabdominal infection. The precise mechanisms underlying adhesion formation are poorly understood. Many compounds and physical barriers have been tested for their ability to prevent adhesions after surgery with varying levels of success. The mouse and rat are important models for the study of abdominal adhesions. Several different techniques for the creation of adhesions in the mouse and rat exist in the literature. Here we describe a protocol utilizing abrasion of the cecum with sandpaper and sutures placed in the right abdominal sidewall. The mouse is anesthetized and the abdomen is prepped. A midline laparotomy is created and the cecum is identified. Sandpaper is used to gently abrade the surface of the cecum. Next, several figure-of-eight sutures are placed into the peritoneum of the right abdominal sidewall. The abdominal cavity is irrigated, a small amount of starch is applied, and the incision is closed. We have found that this technique produces the most consistent adhesions with the lowest mortality rate.

  5. Abdominal sarcoidosis: cross-sectional imaging findings

    PubMed Central

    Gezer, Naciye Sinem; Başara, Işıl; Altay, Canan; Harman, Mustafa; Rocher, Laurence; Karabulut, Nevzat; Seçil, Mustafa

    2015-01-01

    Sarcoidosis is a multisystem inflammatory disease of unknown etiology. The lungs and the lymphoid system are the most commonly involved organs. Extrapulmonary involvement is reported in 30% of patients, and the abdomen is the most common extrapulmonary site with a frequency of 50%–70%. Although intra-abdominal sarcoidosis is usually asymptomatic, its presence may affect the prognosis and treatment options. The lesions are less characteristic and may mimick neoplastic or infectious diseases such as lymphoma, diffuse metastasis, and granulomatous inflammation. The liver and spleen are the most common abdominal sites of involvement. Sarcoidosis of the gastrointestinal system, pancreas, and kidneys are extremely rare. Adenopathy which is most commonly found in the porta hepatis, exudative ascites, and multiple granulomatous nodules studding the peritoneum are the reported manifestations of abdominal sarcoidosis. Since abdominal sarcoidosis is less common and long-standing, unrecognized disease can result in significant morbidity and mortality. Imaging contributes to diagnosis and management of intra-abdominal sarcoidosis. In this report we reviewed the cross-sectional imaging findings of hepatobiliary, gastrointestinal, and genitourinary sarcoidosis. PMID:25512071

  6. Abdominal Wall Transplantation: Skin as a Sentinel Marker for Rejection.

    PubMed

    Gerlach, U A; Vrakas, G; Sawitzki, B; Macedo, R; Reddy, S; Friend, P J; Giele, H; Vaidya, A

    2016-06-01

    Abdominal wall transplantation (AWTX) has revolutionized difficult abdominal closure after intestinal transplantation (ITX). More important, the skin of the transplanted abdominal wall (AW) may serve as an immunological tool for differential diagnosis of bowel dysfunction after transplant. Between August 2008 and October 2014, 29 small bowel transplantations were performed in 28 patients (16 male, 12 female; aged 41 ± 13 years). Two groups were identified: the solid organ transplant (SOT) group (n = 15; 12 ITX and 3 modified multivisceral transplantation [MMVTX]) and the SOT-AWTX group (n = 14; 12 ITX and 2 MMVTX), with the latter including one ITX-AWTX retransplantation. Two doses of alemtuzumab were used for induction (30 mg, 6 and 24 h after reperfusion), and tacrolimus (trough levels 8-12 ng/mL) was used for maintenance immunosuppression. Patient survival was similar in both groups (67% vs. 61%); however, the SOT-AWTX group showed faster posttransplant recovery, better intestinal graft survival (79% vs. 60%), a lower intestinal rejection rate (7% vs. 27%) and a lower rate of misdiagnoses in which viral infection was mistaken and treated as rejection (14% vs. 33%). The skin component of the AW may serve as an immune modulator and sentinel marker for immunological activity in the host. This can be a vital tool for timely prevention of intestinal graft rejection and, more important, avoidance of overimmunosuppression in cases of bowel dysfunction not related to graft rejection.

  7. Candida albicans spondylodiscitis following an abdominal stab wound: forensic considerations.

    PubMed

    Savall, Frederic; Dedouit, Fabrice; Telmon, Norbert; Rougé, Daniel

    2014-03-01

    Candida albicans spondylodiscitis is a fungal infection of the spine which is still unusual in spite of the increasing frequency of predisposing factors. A 22-year-old man received an abdominal stab wound during a physical assault. Initial medical care included surgery, prolonged use of indwelling vascular catheters with administration of broad-spectrum antibiotics, and hospitalization in intensive care. Two months after the event, the victim experienced back pain in the right lumbar region and septic spondylodiscitis secondary to C. albicans was diagnosed three weeks later. This case is noteworthy because of its clinical forensic context. In France, the public prosecutor orders a medico-legal assessment after an assault for all living victims in order to establish a causal relationship between the assault and its complications. In our case, the patient presented numerous risk factors for candidemia and the forensic specialist reasonably accepted that the causal relationship was certain but indirect. We have only found one published case of spondylodiscitis after an abdominal penetrating injury and the pathogenic agent was not mentioned. We have found no case reported in a forensic context. This unusual observation shows that it may be genuinely difficult to prove the causal relationship between an abdominal penetrating injury and an unusual infectious complication such as fungal spondylodiscitis.

  8. Reduced dermis thickness and AGE accumulation in diabetic abdominal skin.

    PubMed

    Niu, Yiwen; Cao, Xiaozan; Song, Fei; Xie, Ting; Ji, Xiaoyun; Miao, Mingyuan; Dong, Jiaoyun; Tian, Ming; Lin, Yuan; Lu, Shuliang

    2012-09-01

    Dermatological problems in diabetes might play an important role in the spontaneous ulcers and impaired wound healing that are seen in diabetic patients. Investigation of the cause of diabetic skin disorders is critical for identifying effective treatment. The abdominal full-thickness skin tissues of 33 patients (14 nondiabetic and 19 diabetic) were analyzed. The cell viability and malondialdehyde (MDA) production of fibroblasts were measured after advanced glycosylation end product (AGE)-bovine serum albumin (BSA) exposure. Cutaneous histological observation showed reduced thickness of the diabetic abdominal dermis with morphological characteristics of obscured multilayer epithelium and shortened, thinned, and disorganized collagen fibrils with focal chronic inflammatory cell infiltration when compared with controls of the same age. Accumulation of AGEs in diabetic skin was prominent. Less hydroxyproline, higher myeloperoxidase activity, and increased MDA content were detected in diabetic skin. In vitro, the time- and dose-dependent inhibitory effects of AGE-BSA on fibroblast viability as well as the fact that AGE-BSA could promote MDA production of fibroblasts were shown. It is shown that the accumulation of AGEs in diabetic skin tissue induces an oxidative damage of fibroblasts and acts as an important contributor to the thinner diabetic abdominal dermis. The authors believe that diabetic cutaneous properties at baseline may increase the susceptibility to injury, and diabetic wounds possess atypical origin in the repair process.

  9. Pathologic aerophagia: a rare cause of chronic abdominal distension

    PubMed Central

    de Jesus, Lisieux Eyer; Cestari, Ana Beatriz C.S.S.; da Silva, Orli Carvalho; Fernandes, Marcia Antunes; Firme, Livia Honorato

    2015-01-01

    Objective: To describe an adolescent with pathologic aerophagia, a rare condition caused by excessive and inappropriate swallowing of air and to review its treatment and differential diagnoses. Case description: An 11-year-old mentally impaired blind girl presenting serious behavior problems and severe developmental delay with abdominal distension from the last 8 months. Her past history included a Nissen fundoplication. Abdominal CT and abdominal radiographs showed diffuse gas distension of the small bowel and colon. Hirschsprung's disease was excluded. The distention was minimal at the moment the child awoke and maximal at evening, and persisted after control of constipation. Audible repetitive and frequent movements of air swallowing were observed. The diagnosis of pathologic aerophagia associated to obsessive-compulsive disorder and developmental delay was made, but pharmacological treatment was unsuccessful. The patient was submitted to an endoscopic gastrostomy, permanently opened and elevated relative to the stomach. The distention was resolved, while maintaining oral nutrition. Comments: Pathologic aerophagia is a rare self-limiting condition in normal children exposed to high levels of stress and may be a persisting problem in children with psychiatric or neurologic disease. In this last group, the disease may cause serious complications. Pharmacological and behavioral treatments are ill-defined. Severe cases may demand surgical strategies, mainly decompressive gastrostomy. PMID:26100594

  10. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

    SciTech Connect

    Guzzardi, Giuseppe Fossaceca, Rita; Divenuto, Ignazio; Musiani, Antonello; Brustia, Piero; Carriero, Alessandro

    2010-08-15

    Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

  11. Automatic segmentation of abdominal vessels for improved pancreas localization

    NASA Astrophysics Data System (ADS)

    Farag, Amal; Liu, Jiamin; Summers, Ronald M.

    2014-03-01

    Accurate automatic detection and segmentation of abdominal organs from CT images is important for quantitative and qualitative organ tissue analysis as well as computer-aided diagnosis. The large variability of organ locations, the spatial interaction between organs that appear similar in medical scans and orientation and size variations are among the major challenges making the task very difficult. The pancreas poses these challenges in addition to its flexibility which allows for the shape of the tissue to vastly change. Due to the close proximity of the pancreas to numerous surrounding organs within the abdominal cavity the organ shifts according to the conditions of the organs within the abdomen, as such the pancreas is constantly changing. Combining these challenges with typically found patient-to-patient variations and scanning conditions the pancreas becomes harder to localize. In this paper we focus on three abdominal vessels that almost always abut the pancreas tissue and as such useful landmarks to identify the relative location of the pancreas. The splenic and portal veins extend from the hila of the spleen and liver, respectively, travel through the abdominal cavity and join at a position close to the head of the pancreas known as the portal confluence. A third vein, the superior mesenteric vein, anastomoses with the other two veins at the portal confluence. An automatic segmentation framework for obtaining the splenic vein, portal confluence and superior mesenteric vein is proposed using 17 contrast enhanced computed-tomography datasets. The proposed method uses outputs from the multi-organ multi-atlas label fusion and Frangi vesselness filter to obtain automatic seed points for vessel tracking and generation of statistical models of the desired vessels. The approach shows ability to identify the vessels and improve localization of the pancreas within the abdomen.

  12. Showing What They Know

    ERIC Educational Resources Information Center

    Cech, Scott J.

    2008-01-01

    Having students show their skills in three dimensions, known as performance-based assessment, dates back at least to Socrates. Individual schools such as Barrington High School--located just outside of Providence--have been requiring students to actively demonstrate their knowledge for years. The Rhode Island's high school graduating class became…

  13. The Ozone Show.

    ERIC Educational Resources Information Center

    Mathieu, Aaron

    2000-01-01

    Uses a talk show activity for a final assessment tool for students to debate about the ozone hole. Students are assessed on five areas: (1) cooperative learning; (2) the written component; (3) content; (4) self-evaluation; and (5) peer evaluation. (SAH)

  14. What Do Maps Show?

    ERIC Educational Resources Information Center

    Geological Survey (Dept. of Interior), Reston, VA.

    This curriculum packet, appropriate for grades 4-8, features a teaching poster which shows different types of maps (different views of Salt Lake City, Utah), as well as three reproducible maps and reproducible activity sheets which complement the maps. The poster provides teacher background, including step-by-step lesson plans for four geography…

  15. Show Me the Way

    ERIC Educational Resources Information Center

    Dicks, Matthew J.

    2005-01-01

    Because today's students have grown up steeped in video games and the Internet, most of them expect feedback, and usually gratification, very soon after they expend effort on a task. Teachers can get quick feedback to students by showing them videotapes of their learning performances. The author, a 3rd grade teacher describes how the seemingly…

  16. Chemistry Game Shows

    NASA Astrophysics Data System (ADS)

    Campbell, Susan; Muzyka, Jennifer

    2002-04-01

    We present a technological improvement to the use of game shows to help students review for tests. Our approach uses HTML files interpreted with a browser on a computer attached to an LCD projector. The HTML files can be easily modified for use of the game in a variety of courses.

  17. Honored Teacher Shows Commitment.

    ERIC Educational Resources Information Center

    Ratte, Kathy

    1987-01-01

    Part of the acceptance speech of the 1985 National Council for the Social Studies Teacher of the Year, this article describes the censorship experience of this honored social studies teacher. The incident involved the showing of a videotape version of the feature film entitled "The Seduction of Joe Tynan." (JDH)

  18. Talk Show Science.

    ERIC Educational Resources Information Center

    Moore, Mitzi Ruth

    1992-01-01

    Proposes having students perform skits in which they play the roles of the science concepts they are trying to understand. Provides the dialog for a skit in which hot and cold gas molecules are interviewed on a talk show to study how these properties affect wind, rain, and other weather phenomena. (MDH)

  19. Stage a Water Show

    ERIC Educational Resources Information Center

    Frasier, Debra

    2008-01-01

    In the author's book titled "The Incredible Water Show," the characters from "Miss Alaineus: A Vocabulary Disaster" used an ocean of information to stage an inventive performance about the water cycle. In this article, the author relates how she turned the story into hands-on science teaching for real-life fifth-grade students. The author also…

  20. Time resolved analysis of water drainage in porous asphalt concrete using neutron radiography.

    PubMed

    Poulikakos, L D; Sedighi Gilani, M; Derome, D; Jerjen, I; Vontobel, P

    2013-07-01

    Porous asphalt as a road surface layer controls aquaplaning as rain water can drain through its highly porous structure. The process of water drainage through this permeable layer is studied using neutron radiography. Time-resolved water configuration and distribution within the porous structure are reported. It is shown that radiography depicts the process of liquid water transport within the complex geometry of porous asphalt, capturing water films, filled dead end pores and water islands.

  1. Application of Digital Radiography to Weld Inspection for the Space Shuttle External Fuel Tank

    NASA Technical Reports Server (NTRS)

    Ussery, Warren

    2009-01-01

    This slide presentation reviews NASA's use of digital radiography to inspect the welds of the external tanks used to hold the cryogenic fuels for the Space Shuttle Main Engines. NASA has had a goal of replacing a significant portion of film used to inspect the welds, with digital radiography. The presentation reviews the objectives for converting to a digital system from film, the characteristics of the digital system, the Probability of detection study, the qualification and implementation of the system.

  2. Digital Radiography and X-ray Computed Tomography Slice Inspection of an Aluminum Truss Section

    DTIC Science & Technology

    2011-09-01

    3. Results The DR and XCT scans of the specimen were done using the 225-keV microfocus x - ray tube and II/CCD camera setup in centered rotate-only...Digital Radiography and X - ray Computed Tomography Slice Inspection of an Aluminum Truss Section by William H. Green ARL-MR-791 September...Digital Radiography and X - ray Computed Tomography Slice Inspection of an Aluminum Truss Section William H. Green Weapons and Materials

  3. Biomedical radiography: radiation protection and safety. (latest citations from the NTIS data base). Published Search

    SciTech Connect

    Not Available

    1992-04-01

    The bibliography contains citations concerning the safety of biomedical radiography. Radiation protection methods and techniques are described for both patients and operators. Safety techniques for dental radiology, routine x-rays, radiotherapy, thoracic radiography and other radiology procedures are included. Radiation exposure limits for patients and healthcare workers are defined. (Contains a minimum of 247 citations and includes a subject term index and title list.)

  4. Muon dynamic radiography of density changes induced by hydrothermal activity at the La Soufrière of Guadeloupe volcano.

    PubMed

    Jourde, Kevin; Gibert, Dominique; Marteau, Jacques; de Bremond d'Ars, Jean; Komorowski, Jean-Christophe

    2016-09-15

    Imaging geological structures through cosmic muon radiography is a newly developed technique which shows a great potential in volcanology. Here we demonstrate that muon radiography permits to detect and characterize mass movements in shallow hydrothermal systems of low-energy active volcanoes like the La Soufrière lava dome. We present an experiment conducted on this volcano during the Summer 2014 and bring evidence that very important density changes occurred in three domains of the lava dome. Depending on their position and on the medium porosity the volumes of these domains vary from 1 × 10(6) m(3) to 7 × 10(6) m(3). However, the total mass budget remains approximately constant : two domains show a mass loss (Δm∈ [-0.8;-0.4] × 10(9) kg) and the third one a mass gain (Δm∈ [1.5; 2.5] × 10(9) kg). We attribute the negative mass changes to the formation of steam in shallow hydrothermal reservoir previously partly filled with liquid water. This coincides with the emergence of new fumaroles on top of the volcano. The positive mass change is synchronized with the negative mass changes indicating that liquid water probably flowed from the two reservoirs invaded by steam toward the third reservoir.

  5. Muon dynamic radiography of density changes induced by hydrothermal activity at the La Soufrière of Guadeloupe volcano

    PubMed Central

    Jourde, Kevin; Gibert, Dominique; Marteau, Jacques; de Bremond d’Ars, Jean; Komorowski, Jean-Christophe

    2016-01-01

    Imaging geological structures through cosmic muon radiography is a newly developed technique which shows a great potential in volcanology. Here we demonstrate that muon radiography permits to detect and characterize mass movements in shallow hydrothermal systems of low-energy active volcanoes like the La Soufrière lava dome. We present an experiment conducted on this volcano during the Summer 2014 and bring evidence that very important density changes occurred in three domains of the lava dome. Depending on their position and on the medium porosity the volumes of these domains vary from 1 × 106 m3 to 7 × 106 m3. However, the total mass budget remains approximately constant : two domains show a mass loss (Δm∈ [−0.8;−0.4] × 109 kg) and the third one a mass gain (Δm∈ [1.5; 2.5] × 109 kg). We attribute the negative mass changes to the formation of steam in shallow hydrothermal reservoir previously partly filled with liquid water. This coincides with the emergence of new fumaroles on top of the volcano. The positive mass change is synchronized with the negative mass changes indicating that liquid water probably flowed from the two reservoirs invaded by steam toward the third reservoir. PMID:27629497

  6. Accuracy of CBCT, Digital Radiography and Cross-Sectioning for the Evaluation of Mandibular Incisor Root Canals

    PubMed Central

    Assadian, Hadi; Dabbaghi, Arash; Gooran, Morteza; Eftekhar, Behrouz; Sharifi, Sanaz; Shams, Nassim; Dehghani Najvani, Ali; Tabesh, Hamed

    2016-01-01

    Introduction: The aim of this study was to compare the accuracy of cone-beam computed tomography (CBCT), digital radiography and tooth sectioning in evaluating root canal morphology of mandibular incisors in an in vitro setting. Methods and Materials: A total of 76 samples were imaged using CBCT, and digital radiography in straight and angled views. The samples were then sectioned at different distances from the apex for further visualization under stereomicroscope. The agreement between the observers was statistically analyzed by kappa correlation coefficient and the chi-square test. Results: The results showed that the majority of the samples had a single canal (Vertucci’s Type I). CBCT analysis reported more frequent multi-canal roots in comparison with the other techniques. In pairwise comparisons, the highest agreement was found between digital radiographic imaging and microscopic cross-sectioning both in terms of canal configuration and the number of root canals. Conclusion: None of the used imaging techniques per se could adequately show the exact internal anatomical configuration in accordance with the gold standard. PMID:27141217

  7. Muon dynamic radiography of density changes induced by hydrothermal activity at the La Soufrière of Guadeloupe volcano

    NASA Astrophysics Data System (ADS)

    Jourde, Kevin; Gibert, Dominique; Marteau, Jacques; de Bremond D’Ars, Jean; Komorowski, Jean-Christophe

    2016-09-01

    Imaging geological structures through cosmic muon radiography is a newly developed technique which shows a great potential in volcanology. Here we demonstrate that muon radiography permits to detect and characterize mass movements in shallow hydrothermal systems of low-energy active volcanoes like the La Soufrière lava dome. We present an experiment conducted on this volcano during the Summer 2014 and bring evidence that very important density changes occurred in three domains of the lava dome. Depending on their position and on the medium porosity the volumes of these domains vary from 1 × 106 m3 to 7 × 106 m3. However, the total mass budget remains approximately constant : two domains show a mass loss (Δm∈ [‑0.8‑0.4] × 109 kg) and the third one a mass gain (Δm∈ [1.5; 2.5] × 109 kg). We attribute the negative mass changes to the formation of steam in shallow hydrothermal reservoir previously partly filled with liquid water. This coincides with the emergence of new fumaroles on top of the volcano. The positive mass change is synchronized with the negative mass changes indicating that liquid water probably flowed from the two reservoirs invaded by steam toward the third reservoir.

  8. [Duodenal perforation after blunt abdominal trauma].

    PubMed

    Schneider, R; Moebius, C; Thelen, A; Jonas, S

    2009-12-01

    Duodenal perforation after a blunt abdominal trauma is a rare emergency situation that can result in life-threatening complications. We report on a woman who had a perforation of the duodenum after a supposed mild blunt abdominal trauma. Unremarkable at the initial presentation, the patient presented with acute abdominal pain and a retroperitoneal abscess five days after the initial trauma. The duodenal repair was performed with a Roux-Y anastomosis. Difficulties in diagnosis are very common, but the early recognition of the rupture is essential. The contrast-enhanced CT scan is the gold standard for diagnosis. Surgical management depends on the severity of the trauma and must be chosen on an individual basis.

  9. Electromyographic analysis of four popular abdominal exercises.

    PubMed

    Piering, A W; Janowski, A P; Wehrenberg, W B; Moore, M T; Snyder, A C

    1993-01-01

    This study was designed to evaluate the effects of four specific sit-up exercises on muscular activity of the rectus abdominis. Pairs of surface electrodes were placed unilaterally on four quadrants of the rectus abdominis, delimited by tendinous inscriptions, in four male subjects. Electromyographic (EMG) recordings were taken while the subjects performed four different abdominal exercises. Each abdominal exercise was hypothesized to have a specific effect on one of the four quadrants of the rectus abdominis. The four exercises analyzed were: 1) long lying crunch, 2) bent knee crunch, 3) leg raise, and 4) vertical leg crunch. Analysis of the standardized EMG recordings demonstrated no significant differences in the mean muscle activity between the four different quadrants, in the mean muscle activity between the four different exercises, and in interactions between the exercises and the quadrants of the rectus abdominis. We conclude that none of the four abdominal exercises studied are specific for strengthening individual muscle quadrants of the rectus abdominis.

  10. Large hiatal hernia at chest radiography in a woman with cardiorespiratory symptoms.

    PubMed

    Torres, Daniele; Parrinello, Gaspare; Cardillo, Mauro; Pomilla, Marina; Trapanese, Caterina; Michele, Bellanca; Lupo, Umberto; Schimmenti, Caterina; Cuttitta, Francesco; Pietrantoni, Rossella; Vogiatzis, Danai; Licata, Giuseppe

    2012-11-01

    Hiatal hernia (HH) is a frequent entity. Rarely, it may exert a wide spectrum of clinical presentations mimicking acute cardiovascular events such as angina-like chest pain until manifestations of cardiac compression that can include postprandial syncope, exercise intolerance, respiratory function, recurrent acute heart failure, and hemodynamic collapse. A 69-year-old woman presented to the emergency department complaining of fatigue on exertion, cough, and episodes of restrosternal pain with less than 1 hour of duration. Her medical history only included some episodes of bronchitis and no history of hypertension. The 12-lead electrocardiogram demonstrated sinus rhythm with right bundle-branch block. Laboratory tests, including cardiac troponin I, were within normal reference values. Chest radiography showed no significant pulmonary alterations and revealed in mediastinum a huge abnormal shadow overlapping the right heart compatible with a gastric bubble.The gastroscopy confirmed a large HH. A 2-dimensional transthoracic echocardiogram, using all standard and modified apical and parasternal views, revealed an echolucent mass, compatible with HH, compressing the right atrium. Also, it showed an altered left ventricular relaxation and a mild increase of pulmonary artery pressure (35 mm Hg). Spirometry showed a mild obstruction of the small airways, whereas coronary angiography showed normal coronary arteries. We concluded that the patient's symptomatology was related to the compressive effects of the large hiatal ernia, a neglected cause of cardiorespiratory symptoms. The surgical repair of HH was indicated.

  11. A transportable neutron radiography system based on a SbBe neutron source

    NASA Astrophysics Data System (ADS)

    Fantidis, J. G.; Nicolaou, G. E.; Tsagas, N. F.

    2009-07-01

    A transportable neutron radiography system, incorporating a SbBe neutron source, has been simulated using the MCNPX code. Design provisions have allowed two radiography systems to be utilised using the same SbBe neutron source. In this respect, neutron radiographies can be carried out using the photoneutrons produced when the 124Sb is surrounded by the Be target. Alternatively, γ-radiography can be utilised with the photons from the 124Sb with the target removed. Appropriate collimators were simulated for each of the radiography modes. Apart from Be, the materials considered were compatible with the European Union Directive on 'Restriction of Hazardous Substances' (RoHS) 2002/95/EC, hence excluding the use of cadmium and lead. Bismuth was chosen as the material for γ-radiation shielding and the proposed system allowed a maximum activity of the 124Sb up to 1.85×1013 Bq. The system simulated allows different object sizes to be studied with a wide range of radiography parameters.

  12. Diagnostic Accuracy of Cone-Beam Computed Tomography and Periapical Radiography in Internal Root Resorption

    PubMed Central

    Madani, Zahrasadat; Moudi, Ehsan; Bijani, Ali; Mahmoudi, Elham

    2016-01-01

    Introduction: The aim of this study was to compare the diagnostic value of cone-beam computed tomography (CBCT) and periapical (PA) radiography in detecting internal root resorption. Methods and Materials: Eighty single rooted human teeth with visible pulps in PA radiography were split mesiodistally along the coronal plane. Internal resorption like lesions were created in three areas (cervical, middle and apical) in labial wall of the canals in different diameters. PA radiography and CBCT images were taken from each tooth. Two observers examined the radiographs and CBCT images to evaluate the presence of resorption cavities. The data were statistically analyzed and degree of agreement was calculated using Cohen’s kappa (k) values. Results: The mean±SD of agreement coefficient of kappa between the two observers of the CBCT images was calculated to be 0.681±0.047. The coefficients for the direct, mesial and distal PA radiography were 0.405±0.059, 0.421±0.060 and 0.432±0.056, respectively (P=0.001). The differences in the diagnostic accuracy of resorption of different sizes were statistically significant (P<0.05); however, the PA radiography and CBCT, had no statistically significant differences in detection of internal resorption lesions in the cervical, middle and apical regions. Conclusion: Though, CBCT has a higher sensitivity, specificity, positive predictive value and negative predictive value in comparison with conventional radiography, this difference was not significant. PMID:26843878

  13. Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.

    PubMed

    Tanaka, Rie

    2016-07-01

    Dynamic chest radiography is a flat-panel detector (FPD)-based functional X-ray imaging, which is performed as an additional examination in chest radiography. The large field of view (FOV) of FPDs permits real-time observation of the entire lungs and simultaneous right-and-left evaluation of diaphragm kinetics. Most importantly, dynamic chest radiography provides pulmonary ventilation and circulation findings as slight changes in pixel value even without the use of contrast media; the interpretation is challenging and crucial for a better understanding of pulmonary function. The basic concept was proposed in the 1980s; however, it was not realized until the 2010s because of technical limitations. Dynamic FPDs and advanced digital image processing played a key role for clinical application of dynamic chest radiography. Pulmonary ventilation and circulation can be quantified and visualized for the diagnosis of pulmonary diseases. Dynamic chest radiography can be deployed as a simple and rapid means of functional imaging in both routine and emergency medicine. Here, we focus on the evaluation of pulmonary ventilation and circulation. This review article describes the basic mechanism of imaging findings according to pulmonary/circulation physiology, followed by imaging procedures, analysis method, and diagnostic performance of dynamic chest radiography.

  14. Imaging for chronic abdominal pain in adults.

    PubMed

    Mendelson, Richard

    2015-04-01

    Diagnostic imaging is often not indicated in chronic abdominal pain. In particular, undifferentiated abdominal pain is rarely an indication for a CT scan. CT scanning is overused even when imaging is required. Other modalities may be preferable. A normal CT scan does not rule out cancer. Alarm symptoms, including anaemia, blood in the stool, waking at night with gastrointestinal symptoms, and weight loss, should be investigated. The most appropriate modality depends on the symptoms. Clinical information on request forms for CT scans should be specific and include the suspected condition as this helps the radiologist to determine an appropriate imaging protocol.

  15. [Penetrating abdominal wounds. Apropos of 330 cases].

    PubMed

    Nejjar, M; Bennani, S; Zerouali, O N

    1991-01-01

    Penetrating abdominal wounds are frequent and serious. 330 cases have been treated in the Department of Emergencies and visceral Surgery at Averroes Hospital of Casablanca from 1980 to 1990. The predominance of male sex is noted, and these wounds are always the result of aggression by white arm. All patients have been operated, the white laparotomy rate is of 36%. The classic interventionist attitude is still recommended in spite of this high rate, because our present conditions can't permit us a rigorous watching. According to abdominal lesions, the different interventions are reviewed, and their indications are detailed.

  16. Hypovolemic shock in children: abdominal CT manifestations.

    PubMed

    Taylor, G A; Fallat, M E; Eichelberger, M R

    1987-08-01

    The authors describe a "hypoperfusion complex," seen on abdominal computed tomography, which consists of marked, diffuse dilatation of the intestine with fluid; abnormally intense contrast enhancement of the bowel wall, mesentery, kidneys, and/or pancreas; decreased caliber of the abdominal aorta and inferior vena cava; and moderate to large peritoneal fluid collections. This complex was present in three patients less than 2 years of age and was associated with severe injury and a poor outcome. Recognition of this constellation of findings may help direct attention to the patient's serious hemodynamic abnormality as much as to individual organ defects.

  17. [Intraabdominal hypertension and abdominal compartment syndrome].

    PubMed

    Sonne, Morten; Hillingsø, Jens

    2008-02-11

    Intraabdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are rare conditions with high mortality. IAH is an intraabdominal pressure (IAP) above 12 mmHg and ACS an IAP above 20 mmHg with evidence of organ dysfunction. IAP is measured indirectly via the bladder or stomach. Various medical and surgical conditions increase the intraabdominal volume. When the content exceeds the compliance of the abdominal wall, the IAP rises. Increased IAP affects the functioning of the brain, lungs, circulation, kidneys, and bowel. The treatment of ACS is a reduction of IAP.

  18. Risk Factors and Outcome for Massive Intra-Abdominal Bleeding Among Patients With Infected Necrotizing Pancreatitis.

    PubMed

    Shen, Xiao; Sun, Jing; Zhang, Jingzhu; Ke, Lu; Tong, Zhihui; Li, Gang; Jiang, Wei; Li, Weiqin; Li, Jieshou

    2015-07-01

    The incidence of acute bleeding is reported to be 13.5% in patients with acute necrotizing pancreatitis. However, of all the bleeding events, intra-abdominal bleeding was less studied in the literature and its risk factors have not been well defined yet. The purpose of the present study was to investigate the risk factors for massive intra-abdominal bleeding among the patients with infected necrotizing pancreatitis and assessed the outcome of these patients. Both univariate and multivariate logistic regression models were applied for evaluating risk factors for intra-abdominal bleeding using 33 indices, including age, sex, etiology of acute pancreatitis (AP), APACHE II score, etc. Outcome assessments such as mortality, hospital and intensive care unit (ICU) durations, and cost were also compared between patients with or without intra-abdominal bleeding. Acute kidney injury (AKI) (odds ratio [OR]: 7.54, 95% confidence interval [CI]: 2.53-22.52, P < 0.001) and number of operation (OR: 8.84, 95% CI: 2.01-38.86, P = 0.004) were 2 predictors for massive intra-abdominal bleeding in the patients with infected necrotizing pancreatitis. In addition, AP patients with intra-abdominal bleeding also showed significantly higher mortality rate, prolonged hospital and ICU durations, more complications and invasive treatments, as well as increased cost. Our study revealed that AKI and multiple operations were 2 critical factors increasing the risk of intra-abdominal bleeding among patients with infected necrotizing pancreatitis. Additionally, massive intra-abdominal bleeding was also associated with poor prognosis.

  19. Risk Factors and Outcome for Massive Intra-Abdominal Bleeding Among Patients With Infected Necrotizing Pancreatitis

    PubMed Central

    Shen, Xiao; Sun, Jing; Zhang, Jingzhu; Ke, Lu; Tong, Zhihui; Li, Gang; Jiang, Wei; Li, Weiqin; Li, Jieshou

    2015-01-01

    Abstract The incidence of acute bleeding is reported to be 13.5% in patients with acute necrotizing pancreatitis. However, of all the bleeding events, intra-abdominal bleeding was less studied in the literature and its risk factors have not been well defined yet. The purpose of the present study was to investigate the risk factors for massive intra-abdominal bleeding among the patients with infected necrotizing pancreatitis and assessed the outcome of these patients. Both univariate and multivariate logistic regression models were applied for evaluating risk factors for intra-abdominal bleeding using 33 indices, including age, sex, etiology of acute pancreatitis (AP), APACHE II score, etc. Outcome assessments such as mortality, hospital and intensive care unit (ICU) durations, and cost were also compared between patients with or without intra-abdominal bleeding. Acute kidney injury (AKI) (odds ratio [OR]: 7.54, 95% confidence interval [CI]: 2.53–22.52, P < 0.001) and number of operation (OR: 8.84, 95% CI: 2.01–38.86, P = 0.004) were 2 predictors for massive intra-abdominal bleeding in the patients with infected necrotizing pancreatitis. In addition, AP patients with intra-abdominal bleeding also showed significantly higher mortality rate, prolonged hospital and ICU durations, more complications and invasive treatments, as well as increased cost. Our study revealed that AKI and multiple operations were 2 critical factors increasing the risk of intra-abdominal bleeding among patients with infected necrotizing pancreatitis. Additionally, massive intra-abdominal bleeding was also associated with poor prognosis. PMID:26181564

  20. Abdominal Migraine in a Middle-aged Woman

    PubMed Central

    Kunishi, Yosuke; Iwata, Yuri; Ota, Mitsuyasu; Kurakami, Yuichi; Matsubayashi, Mao; Kanno, Masatomo; Kuboi, Yoriko; Yoshie, Koichiro; Kato, Yoshio

    2016-01-01

    A 52-year-old woman presented with recurrent, severe abdominal pain. Laboratory tests and imaging were insignificant, and treatment for functional dyspepsia was ineffective. The poorly localized, dull, and severe abdominal pain, associated with anorexia, nausea, and vomiting, was consistent with abdominal migraine. The symptoms were relieved by loxoprofen and lomerizine, which are used in the treatment of migraine. We herein report a case of abdominal migraine in a middle-aged woman. Abdominal migraine should be considered as a cause of abdominal pain as it might easily be relieved by appropriate treatment. PMID:27725538