Sample records for abdominis plane catheters

  1. Dexmedetomidine in a surgically inserted catheter for transversus abdominis plane block in donor hepatectomy: A prospective randomized controlled study.

    PubMed

    Aboelela, Mohamed Adel; Kandeel, Al-Refaey; Elsayed, Usama; Elmorshedi, Mohamed; Elsarraf, Waleed; Elsayed, Eman; Elgawalby, Ahmed; Sultan, Ahmed Mohamed; Wahab, Mohamed Abdel; Yassen, Amr

    2018-01-01

    Transversus abdominis plane (TAP) block is a promising technique for analgesia after abdominal surgery. This prospective, randomized controlled trial assessed the effect of adding dexmedetomidine to bupivacaine in TAP block for donor hepatectomy. We hypothesized that this would improve postoperative morphine consumption and reduce analgesia related complication and inflammation. A total of 50 donor hepatectomy were enrolled in this study. Patients divided into two equal groups according to drugs used for TAP block. Group (B) received 20 ml of bupivacaine hydrochloride 0.25%, Group (BD) received 20 ml of bupivacaine hydrochloride 0.25% and 0.3 μg/kg dexmedetomidine, on both sides at the end of surgery and every 8 h for 48 h at right side only through inserted catheter. Primary outcome objective was morphine consumption at first 72 h. Secondary outcome objectives were morphine requirement, numbers of intake, time to first intake, pain score numerical analog scale (NAS), postoperative analgesia related complications, recovery of intestinal motility, and inflammatory markers. Data were analyzed, rescue morphine analgesia was significantly lower in (BD) group compared with (B) groups as considering total morphine consumption (B 4 ± 1.9, BD 1.5 ± 0.5, P = 0.03), numbers of morphine intake ( P = 0.04), morphine requirement ( P = 0.03), and first time of analgesia intake ( P = 0.04). NAS was significantly lower in group (BD) compared with group (B) group in the first 12 h (NAS 0 - P = 0.001, NAS 1 - P = 0.03). Adding dexmedetomidine improved gut motility, first oral intake without detectable anti-inflammatory effect. Adding dexmedetomidine to bupivacine in a surgically inserted catheter for TAP block in donor hepatectomy reduced morphine consumption without detectable anti-inflammatory effect.

  2. Colostomy with Transversus Abdominis Plane Block

    PubMed Central

    Tekelioğlu, Ümit Yaşar; Demirhan, Abdullah; Şit, Mustafa; Kurt, Adem Deniz; Bilgi, Murat; Koçoğlu, Hasan

    2015-01-01

    Transversus abdominis plane (TAP) block is one of the abdominal field block. The TAP block is used for both anaesthetic management and post-operative pain therapy in lower abdominal surgery. TAP block is a procedure in which local anaesthetic agents are applied to the anatomic neurofacial space between the internal oblique and the transversus abdominis muscle. TAP block is a good method for post-operative pain control as well as allows for short operations involving the abdominal area. In this article, a case of colostomy under TAP block is presented. PMID:27366540

  3. Four quadrant transversus abdominis plane block and continuous transversus abdominis plane analgesia: a 3-year prospective audit in 124 patients.

    PubMed

    Niraj, G; Kelkar, Aditi; Hart, Elaine; Kaushik, Vipul; Fleet, Danny; Jameson, John

    2015-11-01

    Transversus abdominis plane (TAP) blocks have been reported to be an effective method of providing analgesia after abdominal surgery. To perform a prospective audit on the effectiveness of a novel technique of providing continuous transversus abdominis plane (TAP) analgesia in patients undergoing emergency and elective abdominal surgery. Prospective single center audit over a 3-year period. University hospital. One hundred twenty-four American Society of Anesthesiologists I to IV adult patients presenting for elective as well as emergency abdominal surgery in whom epidural analgesia was contraindicated or refused. Four quadrant TAP blocks and continuous TAP analgesia. Numerical rating scale pain scores at rest and on coughing, nausea scores, satisfaction scores, complications, frequency of analgesia failure, therapeutic failure with continuous TAP analgesia and opioid consumption. One hundred twenty-four patients who received continuous TAP analgesia were audited. This included 34 patients for elective open surgery, 36 patients for emergency laparotomy, and 54 patients who underwent elective laparoscopic colorectal surgery. Surgical incision was within the dermatomal limit of the block in 70% of the patients (88/124). Therapeutic failure with the technique was 10%. Frequency of analgesic failure over the 48-hour period was none in 39% and below 5 episodes in 57%. Four quadrant transversus abdominis plane blocks and continuous TAP analgesia is an effective technique for providing postoperative analgesia after abdominal surgery. It has the potential to be used as a sole analgesic technique when the surgical incision is within its dermatomal limit. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Subcostal Transverse Abdominis Plane Block for Acute Pain Management: A Review.

    PubMed

    Soliz, Jose M; Lipski, Ian; Hancher-Hodges, Shannon; Speer, Barbra Bryce; Popat, Keyuri

    2017-10-01

    The subcostal transverse abdominis plane (SCTAP) block is the deposition of local anesthetic in the transverse abdominis plane inferior and parallel to the costal margin. There is a growing consensus that the SCTAP block provides better analgesia for upper abdominal incisions than the traditional transverse abdominis plane block. In addition, when used as part of a four-quadrant transverse abdominis plane block, the SCTAP block may provide adequate analgesia for major abdominal surgery. The purpose of this review is to discuss the SCTAP block, including its indications, technique, local anesthetic solutions, and outcomes.

  5. Transversus Abdominis Plane Blocks with Single-Dose Liposomal Bupivacaine in Conjunction with a Nonnarcotic Pain Regimen Help Reduce Length of Stay following Abdominally Based Microsurgical Breast Reconstruction.

    PubMed

    Jablonka, Eric M; Lamelas, Andreas M; Kim, Julie N; Molina, Bianca; Molina, Nathan; Okwali, Michelle; Samson, William; Sultan, Mark R; Dayan, Joseph H; Smith, Mark L

    2017-08-01

    Side effects associated with use of postoperative narcotics for pain control can delay recovery after abdominally based microsurgical breast reconstruction. The authors evaluated a nonnarcotic pain control regimen in conjunction with bilateral transversus abdominis plane blocks on facilitating early hospital discharge. A retrospective analysis was performed of consecutive patients who underwent breast reconstruction using abdominally based free flaps, with or without being included in a nonnarcotic protocol using intraoperative transversus abdominis plane blockade. During this period, the use of locoregional analgesia evolved from none (control), to continuous bupivacaine infusion transversus abdominis plane and catheters, to single-dose transversus abdominis plane blockade with liposomal bupivacaine solution. Demographic factors, length of stay, inpatient opioid consumption, and complications were reported for all three groups. One hundred twenty-eight consecutive patients (182 flaps) were identified. Forty patients (62 flaps) were in the infusion-liposomal bupivacaine group, 48 (66 flaps) were in the single-dose blockade-catheter group, and 40 (54 flaps) were in the control group. The infusion-liposomal bupivacaine patients had a significantly shorter hospital stay compared with the single-dose blockade-catheter group (2.65 ± 0.66 versus 3.52 ± 0.92 days; p < 0.0001) and the control group (2.65 ± 0.66 versus 4.05 ± 1.26 days; p < 0.0001). There was no significant difference in flap loss or major complications among groups. When used as part of a nonnarcotic postoperative pain regimen, transversus abdominis plane blocks performed with single injections of liposomal bupivacaine help facilitate early hospital discharge after abdominally based microsurgical breast reconstruction. A trend toward consistent discharge by postoperative day 2 was seen. This could result in significant cost savings for health care systems. Therapeutic, III.

  6. [Subcostal transversus abdominis plane block can improve analgesia after laparoscopic cholecystectomy].

    PubMed

    Vrsajkov, Vladimir; Mančić, Nedjica; Mihajlović, Dunja; Milićević, Suzana Tonković; Uvelin, Arsen; Vrsajkov, Jelena Pantić

    After laparoscopic cholecystectomy, patients have moderate pain in the early postoperative period. Some studies shown beneficial effects of subcostal transversus abdominis plane block on reducing this pain. Our goal was to investigate influence of subcostal transversus abdominis plane block on postoperative pain scores and opioid consumption. We have randomized 76 patients undergoing laparoscopic cholecystectomy to receive either subcostal transversus abdominis plane block (n=38) or standard postoperative analgesia (n=38). First group received bilateral ultrasound guided subcostal transversus abdominis plane block with 20mL of 0.33% bupivacaine per side before operation and tramadol 1mg.kg -1 IV for pain breakthrough (≥6). Second group received after operation tramadol 1mg.kg -1 /6h as standard hospital analgesia protocol. Both groups received acetaminophen 1g/8h IV and metamizole 2.5g/12h. Pain at rest was recorded for each patient using NR scale (0-10) in period of 10min, 30min, 2h, 4h, 8h, 12h and 16h after the surgery. We obtained no difference between groups according age, weight, intraoperative fentanyl consumption and duration of surgery. Subcostal transversus abdominis plane block significantly reduced postoperative pain scores compared to standard analgesia in all periods after surgery. Tramadol consumption was significantly lower in the subcostal transversus abdominis plane (24.29±47.54g) than in the standard analgesia group (270.2±81.9g) (p=0.000). Our results show that subcostal transversus abdominis plane block can provide superior postoperative analgesia and reduction in opioid requirements after laparoscopic cholecystectomy. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  7. A comparison of plasma levobupivacaine concentrations following transversus abdominis plane block and rectus sheath block.

    PubMed

    Yasumura, R; Kobayashi, Y; Ochiai, R

    2016-05-01

    Levobupivacaine is commonly used as the local anaesthetic of choice in peripheral nerve blocks, but its pharmacokinetics have not been fully investigated. We compared the changes in plasma concentrations of levobupivacaine following transversus abdominis plane block and rectus sheath block. Fifty woman undergoing laparoscopy were randomly allocated to receive either a transversus abdominis plane block or an rectus sheath block. In both groups, 2.5 mg.kg(-1) levobupivacaine was administered, and blood samples were obtained 15 min, 30 min, 60 min and 120 min after injection. The mean maximum plasma concentration (Cmax) and mean time to reach Cmax (Tmax) as determined by non-linear regression analysis were 1.05 μg.ml(-1) and 32.4 min in the transversus abdominis plane group and 0.95 μg.ml(-1) and 60.9 min in the rectus sheath group, respectively. The plasma concentration of levobupivacaine peaked earlier in the transversus abdominis plane group than in the rectus sheath group and the maximum plasma concentration depended on the dose administered but not the procedure. © 2016 The Association of Anaesthetists of Great Britain and Ireland.

  8. Transversus abdominis plane block reduces morphine consumption in the early postoperative period following microsurgical abdominal tissue breast reconstruction: a double-blind, placebo-controlled, randomized trial.

    PubMed

    Zhong, Toni; Ojha, M; Bagher, Shaghayegh; Butler, Kate; Srinivas, Coimbatore; McCluskey, Stuart A; Clarke, Hance; O'Neill, Anne C; Novak, Christine B; Hofer, Stefan O P

    2014-11-01

    The analgesic efficacy of the transversus abdominis plane peripheral nerve block following abdominal tissue breast reconstruction has not been studied in a randomized controlled trial. The authors conducted a double-blind, placebo-controlled, 1:1 allocation, two-arm parallel group, superiority design, randomized controlled trial in patients undergoing microsurgical abdominally based breast reconstruction. Intraoperatively, epidural catheters were inserted under direct vision through the triangle of Petit on both sides of the abdomen into the transversus abdominis plane just before rectus fascial closure. Patients received either bupivacaine (study group) or saline (placebo group) through the catheters for 2 postoperative days. All patients received hydromorphone by means of a patient-controlled analgesic pump. The primary outcome was the difference in the parenteral opioid consumption on each postoperative day between the groups. The secondary outcome measures included the following: total in-hospital opioid; antinausea medication; pain, nausea, and sedation scores; Quality of Recovery Score; time to ambulation; and hospital stay duration. Between September of 2011 and June of 2013, 93 patients were enrolled: 49 received bupivacaine and 44 received saline. There were 11 postoperative complications (13 percent); none were related to the catheter. Primary outcomes were completed by 85 of 93 patients (91.3 percent); the mean parenteral morphine consumption was significantly reduced on postoperative day 1 in the bupivacaine group (20.7±20.1 mg) compared with 30.0±19.1 mg in the control group (p=0.02). There were no significant differences in secondary outcomes. Following abdominally based breast reconstruction, transversus abdominis plane peripheral nerve block is safe and significantly reduces morphine consumption in the early postoperative period. Therapeutic, II.

  9. Efficacy of ultrasound-guided transversus abdominis plane block in laparoscopic hysterectomy. Clinical trial.

    PubMed

    Guardabassi, D S; Lupi, S; Agejas, R; Allub, J M; García-Fornari, G

    2017-05-01

    Transversus abdominis plane block is a regional anaesthesia technique that has proven to be effective for postoperative pain reduction in different abdominal surgical procedures. This study evaluated its efficacy on post laparoscopic hysterectomy pain intensity and analgesic consumption. Randomized controlled trial which included 40 patients scheduled for laparoscopic hysterectomy, enrolled in 2 groups: transversus abdominis plane block+systemic analgesia (Group 1; n=20), versus systemic analgesia (Group 2; n=20). Opioid consumption within the first 24 postoperative hours, pain intensity scores at 60min, 2, 8 and 24h after surgery, adverse events related to systemic analgesia and time to hospital discharge were evaluated and registered. We found no differences between both groups in opioid consumption (10mg vs. 7mg; P=.2) and pain scores (NVS) within the first 24 postoperative hours, at 60min (3 vs. 5; P=.65), 120min (0 vs. 2; P=.15), 8 and 24h (0 vs. 0; P>.50) for the last 2 points in time analysed. Adverse events related to medication and time to hospital discharge showed similar results. Adding a transversus abdominis plane block technique to opioid PCA does not seem to improve postoperative pain management in laparoscopic hysterectomy. Patient preparation time and costs could be incremented and complications (although rare) related to the technique could appear. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Comparison of analgesic efficacy of subcostal transversus abdominis plane blocks with epidural analgesia following upper abdominal surgery.

    PubMed

    Niraj, G; Kelkar, A; Jeyapalan, I; Graff-Baker, P; Williams, O; Darbar, A; Maheshwaran, A; Powell, R

    2011-06-01

    Subcostal transversus abdominis plane (TAP) catheters have been reported to be an effective method of providing analgesia after upper abdominal surgery. We compared their analgesic efficacy with that of epidural analgesia after major upper abdominal surgery in a randomised controlled trial. Adult patients undergoing elective open hepatobiliary or renal surgery were randomly allocated to receive subcostal TAP catheters (n=29) or epidural analgesia (n=33), in addition to a standard postoperative analgesic regimen comprising of regular paracetamol and tramadol as required. The TAP group patients received bilateral subcostal TAP catheters and 1 mg.kg(-1) bupivacaine 0.375% bilaterally every 8 h. The epidural group patients received an infusion of bupivacaine 0.125% with fentanyl 2 μg.ml(-1) . The primary outcome measure was visual analogue pain scores during coughing at 8, 24, 48 and 72 h after surgery. We found no significant differences in median (IQR [range]) visual analogue scores during coughing at 8 h between the TAP group (4.0 (2.3-6.0 [0-7.5])) and epidural group (4.0 (2.5-5.3) [0-8.5])) and at 72 h (2.0 (0.8-4.0 [0-5]) and 2.5 (1.0-5.0 [0-6]), respectively). Tramadol consumption was significantly greater in the TAP group (p=0.002). Subcostal TAP catheter boluses may be an effective alternative to epidural infusions for providing postoperative analgesia after upper abdominal surgery. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  11. Comparison of analgesic efficacy of four-quadrant transversus abdominis plane (TAP) block and continuous posterior TAP analgesia with epidural analgesia in patients undergoing laparoscopic colorectal surgery: an open-label, randomised, non-inferiority trial.

    PubMed

    Niraj, G; Kelkar, A; Hart, E; Horst, C; Malik, D; Yeow, C; Singh, B; Chaudhri, S

    2014-04-01

    Posterior transversus abdominis plane blocks have been reported to be an effective method of providing analgesia after lower abdominal surgery. We compared the efficacy of a novel technique of providing continuous transversus abdominis plane analgesia with epidural analgesia in patients on an enhanced recovery programme following laparoscopic colorectal surgery. A non-inferiority comparison was used. Adult patients undergoing elective laparoscopic colorectal surgery were randomly assigned to receive continuous transversus abdominis plane analgesia (n = 35) vs epidural analgesia (n = 35), in addition to a postoperative analgesic regimen comprising regular paracetamol, regular diclofenac and tramadol as required. Sixty-one patients completed the study. The transversus group received four-quadrant transversus abdominis plane blocks and bilateral posterior transversus abdominis plane catheters that were infused with levobupivacaine 0.25% for 48 h. The epidural group received an infusion of bupivacaine and fentanyl. The primary outcome measure was visual analogue scale pain score on coughing at 24 h after surgery. We found no significant difference in median (IQR [range]) visual analogue scores during coughing at 24 h between the transversus group 2.5 (1.0-3.0 [0-5.5]) and the epidural group 2.5 (1.0-5.0 [0-6.0]). The one-sided 97.5% CI was a 0.0 (∞-1.0) difference in means, establishing non-inferiority. There were no significant differences between the groups for tramadol consumption. Success rate was 28/30 (93%) in the transversus group vs 27/31 (87%) in the epidural group. Continuous transversus abdominis plane infusion was non-inferior to epidural infusion in providing analgesia after laparoscopic colorectal surgery. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  12. [The effects of transversus abdominis plane block on analgesic and anesthetic consumption during total abdominal hysterectomy: a randomized controlled study].

    PubMed

    Karaman, Tugba; Ozsoy, Asker Zeki; Karaman, Serkan; Dogru, Serkan; Tapar, Hakan; Sahin, Aynur; Dogru, Hatice; Suren, Mustafa

    A transversus abdominis plane block is a peripheral block method that has been used successfully for pain relief after total abdominal hysterectomy. However, the effects of the combination of the transversus abdominis plane block and general anesthesia on analgesic and anesthetic requirements remain unclear. This randomized placebo-controlled study is aimed to evaluate the effects of transversus abdominis plane block on analgesic and anesthetic consumption during total abdominal hysterectomy under general anesthesia. Sixty-six women undergoing total abdominal hysterectomy were randomized into two groups to receive general anesthesia alone (control group) or with transversus abdominis plane block using 20mL of 0.25% bupivacaine (transversus abdominis plane group). Intraoperative remifentanil and sevoflurane consumption were recorded. We also evaluated the postoperative pain, nausea, quality of recovery scores and rescue analgesic requirement during postoperative 24hours. The total remifentanil and sevoflurane consumption is significantly lower in transversus abdominis plane group; respectively mean (SD) 0.130 (0.25) vs. 0.094 (0.02) mcg.kg -1 .min -1 ; p<0.01 and 0.295 (0.05) vs. 0.243 (0.06) mL.min -1 ; p<0.01. In the postoperative period, pain scores were significantly reduced in transversus abdominis plane group soon after surgery; median (range) 6 (2-10) vs. 3 (0-5); p<0.001, at 2h (5 [3-9] vs. 2.5 [0-6]; p<0.001), at 6h (4 [2-7] vs. 3[0-6], p<0.001), at 12h (3.5 [1-6] vs. 2 [1-5]; p=0.003). The patients in the transversus abdominis plane group had significantly higher QoR-40 scores 190.5 (175-197) vs. 176.5 (141-187); p<0.001). Combining transversus abdominis plane block with general anesthesia can provide reduced opioid and anesthetic consumption and can improve postoperative pain and quality of recovery scores in patients undergoing total abdominal hysterectomy. Copyright © 2018 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All

  13. Quadratus Lumborum Block Versus Transversus Abdominis Plane Block for Postoperative Pain After Cesarean Delivery: A Randomized Controlled Trial.

    PubMed

    Blanco, Rafael; Ansari, Tarek; Riad, Waleed; Shetty, Nanda

    Effective postoperative analgesia after cesarean delivery enhances early recovery, ambulation, and breastfeeding. In a previous study, we established the effectiveness of the quadratus lumborum block in providing pain relief after cesarean delivery compared with patient-controlled analgesia (morphine). In the current study, we hypothesized that this method would be equal to or better than the transversus abdominis plane block with regard to pain relief and its duration of action after cesarean delivery. Between April 2015 and August 2015, we randomized 76 patients scheduled for elective cesarean delivery under spinal anesthesia to receive the quadratus lumborum block or the transversus abdominis plane block for postoperative pain relief. This trial was registered prospectively (NCT 02489851) [corrected]. Patients in the quadratus lumborum block group used significantly less morphine than the transversus abdominis plane block group (P < 0.05) at 12, 24, and 48 hours but not at 4 and 6 hours after cesarean delivery. This group also had significantly fewer morphine demands than the control group (P < 0.05) at 6, 12, 24, and 48 hours after cesarean delivery. No significant differences in visual analog scale results were shown between the 2 groups at rest or with movement. Calculated total pain relief at rest and with movement were similar (P < 0.001) in both groups. The quadratus lumborum block was more effective in reducing morphine consumption and demands than transversus abdominis plane blocks after cesarean section. This effect was observed up to 48 hours postoperatively.

  14. Transversus abdominis plane block in renal allotransplant recipients: A retrospective chart review.

    PubMed

    Gopwani, S R; Rosenblatt, M A

    2016-01-01

    The efficacy of the transversus abdominis plane (TAP) block appears to vary considerably, depending on the surgical procedure and block technique. This study aims to add to the existing literature and provide a more clear understanding of the TAP blocks role as a postoperative analgesic technique, specifically in renal allotransplant recipients. A retrospective chart review was conducted by querying the intraoperative electronic medical record system of a 1200-bed tertiary academic hospital over a 5 months period, and reviewing anesthetic techniques, as well as postoperative morphine equivalent consumption. Fifty renal allotransplant recipients were identified, 13 of whom received TAP blocks while 37 received no regional analgesic technique. All blocks were performed under ultrasound guidance, with 20 mL of 0.25% bupivacaine injected in the transversus abdominis fascial plane under direct visualization. The primary outcome was postoperative morphine equivalent consumption. Morphine consumption was compared with the two-tailed Mann-Whitney U -test. Continuous variables of patient baseline characteristics were analyzed with unpaired t -test and categorical variables with Fischer Exact Test. A P < 0.05 was considered statistically significant. A statistically significant decrease in cumulative morphine consumption was found in the group that received the TAP block at 6 h (2.46 mg vs. 7.27 mg, P = 0.0010), 12 h (3.88 mg vs. 10.20 mg, P = 0.0005), 24 h (6.96 mg vs. 14.75 mg, P = 0.0013), and 48 h (11 mg vs. 20.13 mg, P = 0.0092). The TAP block is a beneficial postoperative analgesic, opiate-sparing technique in renal allotransplant recipients.

  15. Evolution of transversus abdominis plane infiltration techniques for postsurgical analgesia following abdominal surgeries.

    PubMed

    Gadsden, Jeffrey; Ayad, Sabry; Gonzales, Jeffrey J; Mehta, Jaideep; Boublik, Jan; Hutchins, Jacob

    2015-01-01

    Transversus abdominis plane (TAP) infiltration is a regional anesthesia technique that has been demonstrated to be effective for management of postsurgical pain after abdominal surgery. There are several different clinical variations in the approaches used for achieving analgesia via TAP infiltration, and methods for identification of the TAP have evolved considerably since the landmark-guided technique was first described in 2001. There are many factors that impact the analgesic outcomes following TAP infiltration, and the various nuances of this technique have led to debate regarding procedural classification of TAP infiltration. Based on our current understanding of fascial and neuronal anatomy of the anterior abdominal wall, as well as available evidence from studies assessing local anesthetic spread and cutaneous sensory block following TAP infiltration, it is clear that TAP infiltration techniques are appropriately classified as field blocks. While the objective of peripheral nerve block and TAP infiltration are similar in that both approaches block sensory response in order to achieve analgesia, the technical components of the two procedures are different. Unlike peripheral nerve block, which involves identification or stimulation of a specific nerve or nerve plexus, followed by administration of a local anesthetic in close proximity, TAP infiltration involves administration and spread of local anesthetic within an anatomical plane of the surgical site.

  16. Pharmacokinetics of bupivacaine after bilateral ultrasound-guided transversus abdominis plane block following cesarean delivery under spinal anesthesia.

    PubMed

    Trabelsi, B; Charfi, R; Bennasr, L; Marzouk, S Ben; Eljebari, H; Jebabli, N; Sassi, M Ben; Trabelsi, S; Maghrebi, H

    2017-11-01

    Transversus abdominis plane block is an effective method of post-cesarean analgesia. There are no data available about plasma bupivacaine levels after this block in adults. This study aimed to assess bupivacaine pharmacokinetic parameters after ultrasound-guided transversus abdominis plane blocks following cesarean delivery under spinal anesthesia. A prospective observational study in parturients undergoing elective cesarean delivery under hyperbaric bupivacaine spinal anesthesia was conducted. After surgery, patients received bilateral transversus abdominis plane block (50mg bupivacaine each side). Venous blood samples were collected immediately before performing the block and at 10, 20, 30, 45, 60, 90, 120, 180, 240, 720 and 1440minutes. High performance liquid chromatography was used to measure total plasma bupivacaine concentrations. Mean bupivacaine area under the curve (AUC) was calculated from 0 to 24hours. Data were collected from 17 parturients. Mean age and body mass index were 31±6y and 30±4kg/m 2 respectively. Mean plasma bupivacaine concentration before the block was 171ng/mL. Mean peak concentration was 802.36ng/mL (range 231.8 to 3504.5ng/mL). Mean time to peak concentration was 30min and mean area-under-the-curve (0-24h) was 4505.4h.ng/mL. Mean elimination half-life was 8.75h. Three subjects had concentrations above the quoted toxic threshold and mild symptoms suggestive of neurotoxicity were reported by two subjects, but no treatment was required. Single-dose bilateral transversus abdominis plane block using 100mg of bupivacaine, after spinal anesthesia for cesarean delivery, can result in toxic plasma bupivacaine concentrations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Comparison of ultrasound guided transversus abdominis plane block versus local wound infiltration for post operative analgesia in patients undergoing gynaecological surgery under general anaesthesia.

    PubMed

    Ranjit, S; Shrestha, S K

    2014-01-01

    Transversus abdominis plane block has been recently developed as a part of multimodal post operative analgesic techniques. We compared the analgesic efficacy of this technique with local bupivacaine infiltration in patients undergoing gynaecological surgeries with pfannenstiel incision and lower midline incision under general anaesthesia. To evaluate the efficacy of ultrasound guided transversus abdominis plane block for postoperative analgesia. Patients were randomly allocated to three groups: control group (n=15), transversus abdominis plane block group (n=15), who received bilateral transversus abdominis plane blockwith 0.25% bupivacaine, and local infiltration group (n=15), who received local wound infiltration with 0.25% bupivacaine at the end of surgery. All patients received intramuscular diclofenac 12 hourly and intravenous tramadol SOS in the postoperative period. Visual analogue scores for pain were assessed at 1,2,4,8,12 and 24 hours postoperatively and these were compared between the three groups. Average tramadol consumption in 24 hours were also compared among the three groups. Data were subjected to univariate ANOVA test and chi-square test. Level of significance was set at 0.05. Visual analogue scores were significantly less in transversus abdominis plane block group and effect lasted up to 12 hours at rest postoperatively and 8 hours during cough and movement. Bilateral Transversus abdominis plane block was effective in reducing postoperative pain scores for 8 to 12 hours postoperatively. This block was also successful in reducing postoperative opioid requirement.

  18. Transversus Abdominis Plane Block Versus Surgical Site Infiltration for Pain Management After Open Total Abdominal Hysterectomy.

    PubMed

    Gasanova, Irina; Alexander, John; Ogunnaike, Babatunde; Hamid, Cherine; Rogers, David; Minhajuddin, Abu; Joshi, Girish P

    2015-11-01

    Surgical site infiltration and transversus abdominis plane (TAP) blocks are commonly used to improve pain relief after lower abdominal surgery. This randomized, observer-blinded study was designed to compare the analgesic efficacy of TAP blocks with surgical site infiltration in patients undergoing open total abdominal hysterectomy via a Pfannenstiel incision. Patients were randomized to receive either bilateral ultrasound-guided TAP blocks using bupivacaine 0.5% 20 mL on each side (n = 30) or surgical site infiltration with liposomal bupivacaine 266 mg diluted to 60 mL injected in the preperitoneal, subfascial, and subcutaneous planes (n = 30). The remaining aspects of the perioperative care were standardized. An investigator blinded to the group allocation documented pain scores at rest and with coughing, opioid requirements, nausea, vomiting, and rescue antiemetics in the postanesthesia care unit and at 2, 6, 12, 24, and 48 hours postoperatively. The primary outcome measure was pain scores on coughing at 6 hours postoperatively. One patient in each group was excluded from the analysis because of reoperation within 24 hours in the TAP block group and change of incision type in the infiltration group. The pain scores at rest and with coughing were significantly lower in the surgical site infiltration group at all postoperative time points (P < 0.0001) except at rest in the postanesthesia care unit. The opioid requirements between 24 and 48 hours were significantly lower in the infiltration group (P = 0.009). The nausea scores, occurrence of vomiting, and need for rescue antiemetics were similar. Surgical site infiltration provided superior pain relief at rest and on coughing, as well as reduced opioid consumption for up to 48 hours. Future studies need to compare TAP blocks with liposomal bupivacaine with surgical site infiltration with liposomal bupivacaine.

  19. Randomized clinical trial of transversus abdominis plane block versus placebo control in live-donor nephrectomy.

    PubMed

    Hosgood, Sarah A; Thiyagarajan, Umasanker M; Nicholson, Harriet F L; Jeyapalan, Inthira; Nicholson, Michael L

    2012-09-15

    Laparoscopic surgery reduces pain after donor nephrectomy; however, most patients still require a significant amount of postoperative parenteral opiate analgesia. Therefore, there is a need to investigate techniques that might further reduce postoperative pain. This study assessed the safety and efficacy of using a transversus abdominis plane (TAP) block in a randomized, double-blind, placebo-controlled trial. Forty-six patients were analyzed in the trial and were randomized to undergo the TAP block procedure with either bupivacaine (n=24) or saline placebo (Control n=22) injected into the muscle plane. Prefilled syringes were dispensed with the group allocation concealed to maintain blinding. After surgery, the amount of morphine, level of pain, and measures of recovery were recorded. The amount of morphine used 6 hr after surgery was significantly lower in patients receiving TAP block with bupivacaine compared with the control (presented as mean [SD], 12.4 [8.4] vs. 21.2 [14.0] mg; P=0.015). However, the total amount of morphine used was similar in both groups 45.6 [31.4] vs. 52.7 [28.8] mg; P=0.771. Patients in the bupivacaine group experienced significantly less pain on postoperative days 1 (score, 19 [15] vs. 37 [20]; P=0.003) and 2 (score, 11 [10] vs. 19 [13]; P=0.031). Recovery and postoperative hospital stay were similar in both groups. There were no complications associated with the procedure. The TAP block procedure is beneficial in reducing postoperative pain and early morphine requirements in laparoscopic live-donor nephrectomy.

  20. Comparison of Epidural Analgesia with Transversus Abdominis Plane Analgesia for Postoperative Pain Relief in Patients Undergoing Lower Abdominal Surgery: A Prospective Randomized Study.

    PubMed

    Iyer, Sadasivan Shankar; Bavishi, Harshit; Mohan, Chadalavada Venkataram; Kaur, Navdeep

    2017-01-01

    Anesthesiologists play an important role in postoperative pain management. For analgesia after lower abdominal surgery, epidural analgesia and ultrasound-guided transversus abdominis plane (TAP) block are suitable options. The study aims to compare the analgesic efficacy of both techniques. Seventy-two patients undergoing lower abdominal surgery under spinal anesthesia were randomized to postoperatively receive lumbar epidural catheter (Group E) or ultrasound-guided TAP block (Group T) through intravenous cannulas placed bilaterally. Group E received 10 ml 0.125% bupivacaine stat and 10 ml 8 th hourly for 48 h. Group T received 20 ml 0.125% bupivacaine bilaterally stat and 20 ml bilaterally 8 th hourly for 48 h. Pain at rest and on coughing, total paracetamol and tramadol consumption were recorded. Analgesia at rest was comparable between the groups in the first 16 h. At 24 and 48 h, Group E had significantly better analgesia at rest ( P = 0.001 and 0.004 respectively). Patients in Group E had significantly higher number of patients with nil or mild pain on coughing at all times. Paracetamol consumption was comparable in both groups, but tramadol consumption was significantly higher in Group T at the end of 48 h ( P = 0.001). For lower abdominal surgeries, analgesia provided by intermittent boluses of 0.125% is comparable for first 16 h between epidural and TAP catheters. However, the quality of analgesia provided by the epidural catheter is superior to that provided by TAP catheters beyond that both at rest and on coughing with reduced opioid consumption.

  1. Comparison of Epidural Analgesia with Transversus Abdominis Plane Analgesia for Postoperative Pain Relief in Patients Undergoing Lower Abdominal Surgery: A Prospective Randomized Study

    PubMed Central

    Iyer, Sadasivan Shankar; Bavishi, Harshit; Mohan, Chadalavada Venkataram; Kaur, Navdeep

    2017-01-01

    Background: Anesthesiologists play an important role in postoperative pain management. For analgesia after lower abdominal surgery, epidural analgesia and ultrasound-guided transversus abdominis plane (TAP) block are suitable options. The study aims to compare the analgesic efficacy of both techniques. Materials and Methods: Seventy-two patients undergoing lower abdominal surgery under spinal anesthesia were randomized to postoperatively receive lumbar epidural catheter (Group E) or ultrasound-guided TAP block (Group T) through intravenous cannulas placed bilaterally. Group E received 10 ml 0.125% bupivacaine stat and 10 ml 8th hourly for 48 h. Group T received 20 ml 0.125% bupivacaine bilaterally stat and 20 ml bilaterally 8th hourly for 48 h. Pain at rest and on coughing, total paracetamol and tramadol consumption were recorded. Results: Analgesia at rest was comparable between the groups in the first 16 h. At 24 and 48 h, Group E had significantly better analgesia at rest (P = 0.001 and 0.004 respectively). Patients in Group E had significantly higher number of patients with nil or mild pain on coughing at all times. Paracetamol consumption was comparable in both groups, but tramadol consumption was significantly higher in Group T at the end of 48 h (P = 0.001). Conclusion: For lower abdominal surgeries, analgesia provided by intermittent boluses of 0.125% is comparable for first 16 h between epidural and TAP catheters. However, the quality of analgesia provided by the epidural catheter is superior to that provided by TAP catheters beyond that both at rest and on coughing with reduced opioid consumption. PMID:28928569

  2. [Case of Leriche's syndrome treated with safe and effective analgesia after laparotomy by transversus abdominis plane block, rectus sheath block, and continuous wound infusion with ropivacaine].

    PubMed

    Hotta, Arisa; Yagi, Yuuki; Hakata, Saaya; Tsumura, Yae; Shimizu, Motoko; Kukida, Ayako; Nakamoto, Ai; Yoshikawa, Noriko; Oohira, Naoko; Tatekawa, Shigeki

    2013-12-01

    Ultrasound-guided peripheral nerve blocks in the abdominal wall, such as transversus abdominis plane block (TAP block) and rectus sheath block, are now widely used. We report a case of Leriche's syndrome treated with safe and effective analgesia after laparotomy by abdominal wall block and continuous infusion. A 61-year-old man diagnosed with Leriche's syndrome underwent Y-graft replacement for an abdominal aortic aneurysm. Preoperative enhanced and 3-dimensional CTs showed many collateral arterial systems, especially in the right abdominal wall. It was suggested that the right internal iliac artery had been completely occluded, and the left one showed severe stenosis. After the induction of general anesthesia, we recognized collateral arteries through an ultrasound view as on preoperative CTs. We lowered the pulse repetition frequency more than usual in order not to injure them. We injected 0.1875% ropivacaine 60 ml as TAP block, and 20 ml as rectus sheath block. When the wound was closed, a catheter was passed through an 18-gauge Tuohy needle placed above the fascia along the supraumbilical site. After the operation, 0.2% ropivacaine was continuously delivered at a rate of 6 ml hr-1 through the catheter. We could provide the patient with effective analgesia after surgery.

  3. Transversus abdominis plane block as a component of multimodal analgesia for laparoscopic cholecystectomy.

    PubMed

    Oksar, Menekse; Koyuncu, Onur; Turhanoglu, Selim; Temiz, Muhyittin; Oran, Mustafa Cemil

    2016-11-01

    To evaluate and compare intercostal-iliac transversus abdominis plane (TAP) and oblique subcostal TAP (OSTAP) blocks for multimodal analgesia in patients receiving laparoscopic cholecystectomy. A prospective, randomized, double-blinded clinical study. Operating room, postoperative recovery area, and ward. In total, 60 laparoscopic cholecystectomy patients (43 women, 17 men, American Society of Anesthesiologists grades I-II) were enrolled from the general surgery department of our tertiary care center. The patients were assigned to 1 of the 3 groups. Group 1 received TAP blocks (n=20), group 2 received OSTAP blocks (n=20), and group 3 patients were used as controls and received patient-controlled analgesia (PCA) only (n=20). After the induction of anesthesia, blocks were performed bilaterally in study groups 1 and 2, using 20mL of lidocaine (5mg/mL). PCA with intravenous tramadol was routinely provided for all patients during the first 24hours. The intraoperative use of remifentanil, postoperative visual analog scale (VAS) scores, demand for PCA, and total analgesic consumption were recorded. The patients in the control group had greater analgesic demands and analgesic consumption than did those in groups 1 and 2. However, patients in the OSTAP group had lower VAS scores than did those in groups 1 and 3. The demand for analgesia was greater in the control group than in groups 1 and 2. Moreover, lower VAS scores were recorded in the OSTAP group than in groups 1 and 3 and were positively correlated with total PCA consumption among all patients. However, postoperative VAS scores were negatively correlated with the total intraoperative consumption of remifentanil at 24hours. TAP and OSTAP blocks improved postoperative analgesia in patients receiving laparoscopic cholecystectomy, which resulted in lower VAS scores and reduction in total analgesic consumption. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Effect of transversus abdominis plane block on cost of laparoscopic cholecystectomy anesthesia.

    PubMed

    Kokulu, Serdar; Bakı, Elif Doğan; Kaçar, Emre; Bal, Ahmet; Şenay, Hasan; Üstün, Kübra Demir; Yılmaz, Sezgin; Ela, Yüksel; Sıvacı, Remziye Gül

    2014-12-23

    Use of transversus abdominis plane (TAP) block for postoperative analgesia is continuously increasing. However, few studies have investigated intraoperative effects of TAP block. We aimed to study the effects of TAP block in terms of cost-effectiveness and consumption of inhalation agents. Forty patients undergoing laparoscopic cholecystectomy were enrolled in this study. Patients were randomly divided into 2 groups: Group 1 (n=20) patients received TAP block and Group 2 (n=20) patients did not receive TAP block. Standard anesthesia induction was used in all patients. For the maintenance of anesthesia, fractional inspired oxygen (FIO2) of 50% in air with desflurane was used with a fresh gas flow of 4 L/min. All patients were monitored with electrocardiography and for peripheral oxygen saturation (SpO2), end-tidal carbon dioxide (ET), heart rate (HR), noninvasive mean blood pressure (MBP), and bispectral index (BIS). Bilateral TAP blocks were performed under ultrasound guidance to Group 1 patients. The BIS value was maintained at between 40 and 50 during the surgery. The Dion formula was used to calculate consumption of desflurane for each patient. There was no difference between the groups with respect to demographic characteristics of the patients. Duration of anesthesia, surgery time, and dosage of fentanyl were similar in the 2 groups. However, the cost and consumption of desflurane was significantly lower in Group 1. Total anesthesia consumption was lower and the cost-effectiveness of anesthesia was better in TAP block patients with general anesthesia than in non-TAP block patients undergoing laparoscopic cholecystectomy.

  5. Transversus abdominis plane block vs. wound infiltration in Caesarean section: a randomised controlled trial.

    PubMed

    Telnes, A; Skogvoll, E; Lonnée, H

    2015-04-01

    Multiple studies suggest that transversus abdominis plane (TAP) block (without intrathecal morphine) after Caesarean section (CS) reduces post-operative morphine consumption. In our study, we wanted to compare the analgesic effect of TAP block with infiltration of the wound after CS. We included 60 pregnant women scheduled for elective CS under spinal anaesthesia in a randomised, single-centre, double-blind study. Thirty patients received ultrasound-guided TAP block using 20 ml bupivacaine 0.25% with adrenaline 5 μg/ml bilaterally and 20 ml normal saline as wound infiltration (TAP group). The other 30 patients (the control group) received normal saline 20 ml bilaterally in the TAP, and 20 ml bupivacaine 0.25% with adrenaline 5 μg/ml as wound infiltration. The main outcome was cumulative morphine consumption at 48 h after surgery. In addition, continuous morphine consumption, pain scores and side effects were registered. Fifty-seven patients completed the study. Cumulative morphine consumption at 48 h (mean±standard deviation) was 41±34 mg in the TAP group and 38±27 mg in the control group (P=0.7); a difference of 3 mg (95% confidence interval -13 to 19 mg). Morphine consumption at any time up to 48 h was virtually identical in both groups. Side effects were similar, except for a higher degree of sedation in the TAP group (P=0.04). Compared with wound infiltration with local anaesthetics, TAP block did not reduce cumulative morphine consumption following CS. The TAP block was associated with more pronounced sedation. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Efficacy of transversus abdominis plane block with liposomal bupivacaine during open abdominal wall reconstruction.

    PubMed

    Fayezizadeh, Mojtaba; Majumder, Arnab; Neupane, Ruel; Elliott, Heidi L; Novitsky, Yuri W

    2016-09-01

    Transversus abdominis plane block (TAPb) is an analgesic adjunct used for abdominal surgical procedures. Liposomal bupivacaine (LB) demonstrates prolonged analgesic effects, up to 72 hours. We evaluated the analgesic efficacy of TAPb using LB for patients undergoing open abdominal wall reconstruction (AWR). Fifty patients undergoing AWR with TAPb using LB (TAP-group) were compared with a matched historical cohort undergoing AWR without TAPb (control group). Outcome measures included postoperative utilization of morphine equivalents, numerical rating scale pain scores, time to oral narcotics, and length of stay (LOS). Cohorts were matched demographically. No complications were associated with TAPb or LB. TAP-group evidenced significantly reduced narcotic requirements on operative day (9.5 mg vs 16.5 mg, P = .004), postoperative day (POD) 1 (26.7 mg vs 39.5 mg, P = .01) and POD2 (29.6 mg vs 40.7 mg, P = .047) and pain scores on operative day (5.1 vs 7.0, P <.001), POD1 (4.2 vs 5.5, P = .002), and POD2 (3.9 vs 4.8, P = .04). In addition, TAP-group demonstrated significantly shorter time to oral narcotics (2.7 days vs 4.0 days, P <.001) and median LOS (5.2 days vs 6.8 days, P = .004). TAPb with LB demonstrated significant reductions in narcotic consumption and improved pain control. TAPb allowed for earlier discontinuation of intravenous narcotics and shorter LOS. Intraoperative TAPb with LB appears to be an effective adjunct for perioperative analgesia in patients undergoing open AWR. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Efficacy of transverse abdominis plane block in reduction of postoperation pain in laparoscopic cholecystectomy.

    PubMed

    Saliminia, Alireza; Azimaraghi, Omid; Babayipour, Shiva; Ardavan, Kamelia; Movafegh, Ali

    2015-12-01

    Transversus abdominis plane (TAP) block is a recently introduced regional anesthesia technique that is used for postoperative pain reduction in some abdominal surgeries. The present study evaluated the efficacy of the TAP block on the post laparoscopic cholecystectomy pain intensity and analgesic consumption. Fifty-four patients were enrolled in three groups: TAP block with normal saline (Group 1, n = 18); TAP block with bupivacaine (Group 2, n = 18); and TAP block with bupivacaine plus sufentanil (Group 3, n = 18). The time to the first fentanyl request, fentanyl consumption in the 24 hours following surgery, and postoperative pain intensity at 30 minutes, 1 hour, 6 hours, 12 hours, and 24 hours following discharge for recovery were measured and recorded. The total amount of 24-hour fentanyl consumption was higher in Group 1 (877.8 ± 338.8 μg) than either Group 2 (566.7 ± 367.8 μg) or Group 3 (555.5 ± 356.8 μg; p = 0.03). Postoperative pain score was higher in Group 1 than intervention groups (p = 0.006); however, there was no significant difference in intervention groups. The time to the first fentanyl request in Group 1 (79.44 ± 42.2) was significantly lower than Group 3 (206.38 ± 112.7; p = 0.001). The present study demonstrated that bilateral TAP block with 0.5% bupivacaine reduces post laparoscopic cholecystectomy pain intensity and fentanyl request and prolongs time to the first analgesic request. Adding sufentanil to the block solution reduced neither pain intensity nor fentanyl further consumption. Copyright © 2015. Published by Elsevier B.V.

  8. Transversus Abdominis Plane Block for Post Hysterectomy Pain: A Systematic Review and Meta-Analysis.

    PubMed

    Bacal, Vanessa; Rana, Urvi; McIsaac, Daniel I; Chen, Innie

    2018-04-30

    The objective of this study was to address the efficacy of transversus abdominis plane (TAP) blocks in pain management among women who undergo elective hysterectomy for benign pathology in both open and minimally invasive surgeries. We performed a systematic review by searching for bibliographic citations from Medline, Embase and Cochrane Library. MeSH headings for TAP blocks and hysterectomy were combined and restricted to the English language. We included RCTs comparing TAP blocks to placebo or no block in patients who underwent elective hysterectomy. Pain was measured using a visual analog score (VAS) on a scale of 0-100. We calculated pooled mean differences in VAS and total morphine consumption at 2 and 24 hours by performing a random effects meta-analysis. Fourteen studies met the inclusion criteria, comprising 855 participants. At 2 hours, mean VAS scores for patients who underwent TAP blocks were significantly lower after both total abdominal hysterectomy (TAH) (mean difference -14.97 [CI: -20.35- -9.59]) and total laparoscopic hysterectomy (TLH) (-18.16 [CI: -34.78- -1.53]) compared to placebo or no block. Pain scores at 24 hours for patients who underwent TAPB were significantly lower after both TAH (-10.09 [CI: -17.35- -2.83]) and TLH (-9.12 [CI: -18.12- -0.13]) compared to placebo or no block. Mean difference in morphine consumption was -9.53 mg (CI -15.43- -3.63) for TAH and -3.15 mg (CI: -8.41- 2.12) for TLH. In conclusion, TAP blocks provide significant postoperative early and delayed pain control compared to placebo or no block among women who undergo hysterectomy. There was reduced morphine consumption among patients who underwent TAH, but not after TLH. Copyright © 2018. Published by Elsevier Inc.

  9. Effect of Transversus Abdominis Plane Block on Cost of Laparoscopic Cholecystectomy Anesthesia

    PubMed Central

    Kokulu, Serdar; Bakı, Elif Doğan; Kaçar, Emre; Bal, Ahmet; Şenay, Hasan; Üstün, Kübra Demir; Yılmaz, Sezgin; Ela, Yüksel; Sıvacı, Remziye Gül

    2014-01-01

    Background Use of transversus abdominis plane (TAP) block for postoperative analgesia is continuously increasing. However, few studies have investigated intraoperative effects of TAP block. We aimed to study the effects of TAP block in terms of cost-effectiveness and consumption of inhalation agents. Material/Methods Forty patients undergoing laparoscopic cholecystectomy were enrolled in this study. Patients were randomly divided into 2 groups: Group 1 (n=20) patients received TAP block and Group 2 (n=20) patients did not receive TAP block. Standard anesthesia induction was used in all patients. For the maintenance of anesthesia, fractional inspired oxygen (FIO2) of 50% in air with desflurane was used with a fresh gas flow of 4 L/min. All patients were monitored with electrocardiography and for peripheral oxygen saturation (SpO2), end-tidal carbon dioxide (ET), heart rate (HR), noninvasive mean blood pressure (MBP), and bispectral index (BIS). Bilateral TAP blocks were performed under ultrasound guidance to Group 1 patients. The BIS value was maintained at between 40 and 50 during the surgery. The Dion formula was used to calculate consumption of desflurane for each patient. Results There was no difference between the groups with respect to demographic characteristics of the patients. Duration of anesthesia, surgery time, and dosage of fentanyl were similar in the 2 groups. However, the cost and consumption of desflurane was significantly lower in Group 1. Conclusions Total anesthesia consumption was lower and the cost-effectiveness of anesthesia was better in TAP block patients with general anesthesia than in non-TAP block patients undergoing laparoscopic cholecystectomy. PMID:25534331

  10. Liposomal Bupivacaine Use in Transversus Abdominis Plane Blocks Reduces Pain and Postoperative Intravenous Opioid Requirement After Colorectal Surgery.

    PubMed

    Stokes, Audrey L; Adhikary, Sanjib D; Quintili, Ashley; Puleo, Frances J; Choi, Christine S; Hollenbeak, Christopher S; Messaris, Evangelos

    2017-02-01

    Enhanced recovery protocols frequently use multimodal postoperative analgesia to improve postoperative outcomes in patients undergoing colorectal surgery. The purpose of this study was to evaluate liposomal bupivacaine use in transversus abdominis plane blocks on postoperative pain scores and opioid use after colorectal surgery. This was a retrospective cohort study comparing outcomes between patients receiving nonliposomal anesthetic (n = 104) and liposomal bupivacaine (n = 303) blocks. The study was conducted at a single tertiary care center. Patients included those identified within an institutional database as inpatients undergoing colorectal procedures between 2013 and 2015 who underwent transversus abdominis plane block for perioperative analgesia. The study measured postoperative pain scores and opioid requirements. Patients receiving liposomal bupivacaine had significantly lower pain scores for the first 24 to 36 postoperative hours. Pain scores were similar after 36 hours. The use of intravenous opioids among the liposomal bupivacaine group decreased by more than one third during the hospitalization (99.1 vs 64.5 mg; p = 0.040). The use of ketorolac was also decreased (49.0 vs 18.3 mg; p < 0.001). In subgroup analysis, the decrease in opioid use was observed between laparoscopic and robotic procedures but not with laparotomies. No significant differences were noted in the use of oral opioids, acetaminophen, or ibuprofen. Postoperative length of stay and total cost were decreased in the liposomal bupivacaine group but did not achieve statistical significance. The study was limited by its retrospective, single-center design and heterogeneity of block administration. Attenuated pain scores observed with liposomal bupivacaine use were associated with significantly lower intravenous opioid and ketorolac use, suggesting that liposomal bupivacaine-containing transversus abdominis plane blocks are well aligned with the opioid-reducing goals of many enhanced

  11. Quadratus lumborum catheters for breast reconstruction requiring transverse rectus abdominis myocutaneous flaps.

    PubMed

    Spence, Nicole Z; Olszynski, Patrycja; Lehan, Anne; Horn, Jean-Lois; Webb, Christopher A J

    2016-06-01

    Patients diagnosed with breast cancer may opt to undergo surgical reconstructive flaps at the time of or after mastectomies. These surgeries leave patients with significant postoperative pain and sometimes involve large surgical beds including graft sites from the abdomen to reconstruct the breast. Consequently, multimodal methods of pain management have become highly favored. Quadratus lumborum catheters offer an opioid-sparing technique that can be performed easily and safely. We present a case of a patient who underwent a breast flap reconstruction and had bilateral quadratus lumborum catheters placed for perioperative pain control.

  12. Perioperative transversus abdominis plane (TAP) blocks for analgesia after abdominal surgery.

    PubMed

    Charlton, Shona; Cyna, Allan M; Middleton, Philippa; Griffiths, James D

    2010-12-08

    The transversus abdominis plane (TAP) block is a peripheral nerve block which anaesthetises the abdominal wall. The increasing use of TAP block, as a form of pain relief after abdominal surgery warrants evaluation of its effectiveness as an adjunctive technique to routine care and, when compared with other analgesic techniques. To assess effects of TAP blocks (and variants) on postoperative analgesia requirements after abdominal surgery. We searched specialised registers of Cochrane Anaesthesia and Cochrane Pain, Palliative and Supportive Care Review Groups, CENTRAL, MEDLINE, EMBASE and CINAHL to June 2010. We included randomised controlled trials (RCTs) comparing TAP block or rectus sheath block with: no TAP or rectus sheath block; placebo; systemic, epidural or any other analgesia. At least two review authors assessed study eligibility and risk of bias, and extracted data. We included eight studies (358 participants), five assessing TAP blocks, three assessing rectus sheath blocks; with moderate risk of bias overall. All studies had a background of general anaesthesia in both arms in most cases.Compared with no TAP block or saline placebo, TAP block resulted in significantly less postoperative requirement for morphine at 24 hours (mean difference (MD) -21.95 mg, 95% confidence interval (CI) -37.91 to 5.96; five studies, 236 participants) and 48 hours (MD -28.50, 95% CI -38.92 to -18.08; one study of 50 participants) but not at two hours (all random-effects analyses). Pain at rest was significantly reduced in two studies, but not a third.Only one of three included studies of rectus sheath blocks found a reduction in postoperative analgesic requirements in participants receiving blocks. One study, assessing number of participants who were pain-free after their surgery, found more participants who received a rectus sheath block to be pain-free for up to 10 hours postoperatively. As with TAP blocks, rectus sheath blocks made no apparent impact on nausea and vomiting

  13. The analgesic efficacy of subcostal transversus abdominis plane block with Mercedes incision.

    PubMed

    Guo, Jian-Guo; Li, Hui-Ling; Pei, Qing-Qing; Feng, Zhi-Ying

    2018-04-10

    Conventional perioperative analgesic modalities (e.g. opioids, epidural analgesia) have their own drawbacks, which limit their clinical application. This study investigated the opioid-sparing effectsof the oblique subcostal transversus abdominis plane (OSTAP) blockade with ropivacaine for the patients undergoing open liver resection with a Mercedes incision. 126 patients who were scheduled for open liver resection were enrolled in this study. Patients were randomly assigned to receive bilateral ultrasound-guided OSTAPblocks with either 0.375% ropivacaine (groupT) or 0.9% isotonic saline (group C). Both groups also received intravenous patient-controlled analgesia and intravenous 40 mg parecoxib every 12 h for a total of 3 days. Preoperative and intraoperative parameters, plus intraoperative and postoperative cumulative sufentanil consumption, were recorded. 70 patients were enrolled in the study finally. There were no significant differences between the two groups with respect to preoperative parameters, and surgical and anesthetic characteristics. The intraoperative sufentanil use, cumulative sufentanil consumption at 5 min after extubation, 2 h, 4 h,12 h and 24 h after operation in group T was significantly less than that in group C (P = 0.001, 0.001, 0.000, 0.000, 0.001 and 0.044, respectively). Compared with group C, postoperative NRS pain scores at rest were significantly lower at 2 h and 4 h postoperatively in group T (P = 0.04and 0.02, respectively); NRS scores at the time of coughing were also significantly lower in group T than in group C at all time points except 5 min after extubation (all P < 0.001). Furthermore, compared with group C, the number of intraoperative vasodilator use, the extubation time and the incidence of nausea was reduced in group T. Ultrasound-guided OSTAP block with ropivacaine can significantly decrease the perioperative cumulative dosage of analgesics and improve analgesic effect without obvious side

  14. A randomised trial of the analgesic efficacy of ultrasound-guided transversus abdominis plane block after caesarean delivery under general anaesthesia.

    PubMed

    Tan, Terry T; Teoh, Wendy H L; Woo, David C M; Ocampo, Cecilia E; Shah, Mukesh K; Sia, Alex T H

    2012-02-01

    Previous studies examining the efficacy of transversus abdominis plane block after caesarean section have mostly been in parturients under spinal anaesthesia. We postulated that the advantage of performing transversus abdominis plane block after caesarean section might be even more obvious after general anaesthesia, resulting in reduced 24-h consumption of morphine. DESIGN, SETTING, PATIENTS AND INTERVENTIONS: In this single centre, randomised double-blind controlled trial, 40 women who underwent caesarean delivery under general anaesthesia were allocated randomly to receive a transversus abdominis plane block or no block. In those who received the block, 20 ml of levobupivacaine 2.5 mg ml was deposited bilaterally into the transversus abdominis plane under ultrasound guidance using a Sonosite Titan (SonoSite, Bothell, Washington, USA) 7-13 MHz linear transducer at the end of surgery when the patient was still anaesthetised. We recorded patient-controlled intravenous morphine use for 24 h, pain scores at rest and activity, sedation, nausea and vomiting, use of antiemetic medication and overall maternal satisfaction. The primary outcome was 24-h morphine consumption. Patients who received the transversus abdominis plane block used significantly less morphine in 24 h than those in the control group [12.3 (2.6) vs. 31.4 mg (3.1), P<0.001) and had higher satisfaction scores [16 (80%) vs. 5 (25%), P = 0.012). There were no differences between groups in the visual analogue pain scores, sedation level, nausea and vomiting or the use of antiemetic medication. Ultrasound-guided transversus abdominis plane block reduced morphine consumption following caesarean section under general anaesthesia, with increased maternal satisfaction.

  15. Transperitoneal rectus sheath block and transversus abdominis plane block for laparoscopic inguinal hernia repair: A novel approach.

    PubMed

    Nagata, Jun; Watanabe, Jun; Nagata, Masato; Sawatsubashi, Yusuke; Akiyama, Masaki; Tajima, Takehide; Arase, Koichi; Minagawa, Noritaka; Torigoe, Takayuki; Nakayama, Yoshifumi; Horishita, Reiko; Kida, Kentaro; Hamada, Kotaro; Hirata, Keiji

    2017-08-01

    A laparoscopic approach for inguinal hernia repair is now considered the gold standard. Laparoscopic surgery is associated with a significant reduction in postoperative pain. Epidural analgesia cannot be used in patients with perioperative anticoagulant therapy because of complications such as epidural hematoma. As such, regional anesthetic techniques, such as ultrasound-guided rectus sheath block and transversus abdominis plane block, have become increasingly popular. However, even these anesthetic techniques have potential complications, such as rectus sheath hematoma, if vessels are damaged. We report the use of a transperitoneal laparoscopic approach for rectus sheath block and transversus abdominis plane block as a novel anesthetic procedure. An 81-year-old woman with direct inguinal hernia underwent laparoscopic transabdominal preperitoneal inguinal repair. Epidural anesthesia was not performed because anticoagulant therapy was administered. A Peti-needle™ was delivered through the port, and levobupivacaine was injected though the peritoneum. Surgery was performed successfully, and the anesthetic technique did not affect completion of the operative procedure. The patient was discharged without any complications. This technique was feasible, and the procedure was performed safely. Our novel analgesia technique has potential use as a standard postoperative regimen in various laparoscopic surgeries. Additional prospective studies to compare it with other techniques are required. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  16. Postoperative analgesic efficacy of ultrasound-guided ilioinguinal-iliohypogastric nerve block compared with medial transverse abdominis plane block in inguinal hernia repair: A prospective, randomised trial.

    PubMed

    Bhatia, Nidhi; Sen, Indu Mohini; Mandal, Banashree; Batra, Ankita

    2018-03-29

    Analgesic efficacy of ultrasound-guided transverse abdominis plane block, administered a little more medially, just close to the origin of the transverse abdominis muscle has not yet been investigated in patients undergoing unilateral inguinal hernia repair. We hypothesised that medial transverse abdominis plane block would provide comparable postoperative analgesia to ilioinguinal-iliohypogastric nerve block in inguinal hernia repair patients. This prospective, randomised trial was conducted in 50 ASA I and II male patients≥18 years of age. Patients were randomised into two groups to receive either pre-incisional ipsilateral ultrasound-guided ilioinguinal-iliohypogastric nerve block or medial transverse abdominis plane block, with 0.3ml/kg of 0.25% bupivacaine. Our primary objective was postoperative 24-hour analgesic consumption and secondary outcomes included pain scores, time to first request for rescue analgesic and side effects, if any, in the postoperative period. There was no significant difference in the total postoperative analgesic consumption [group I: 66.04mg; group II: 68.33mg (P value 0.908)]. Time to first request for rescue analgesic was delayed, though statistically non-significant (P value 0.326), following medial transverse abdominis plane block, with excellent pain relief seen in 58.3% patients as opposed to 45.8% patients in ilioinguinal-iliohypogastric nerve block group. Medial transverse abdominis plane block being a novel, simple and easily performed procedure can serve as an useful alternative to ilioinguinal-iliohypogastric nerve block for providing postoperative pain relief in inguinal hernia repair patients. Copyright © 2018 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  17. Transversus Abdominis Plane Block Versus Wound Infiltration for Analgesia After Cesarean Delivery: A Randomized Controlled Trial.

    PubMed

    Tawfik, Mohamed Mohamed; Mohamed, Yaser Mohamed; Elbadrawi, Rania Elmohamadi; Abdelkhalek, Mostafa; Mogahed, Maiseloon Mostafa; Ezz, Hanaa Mohamed

    2017-04-01

    Transversus abdominis plane (TAP) block and local anesthetic wound infiltration provide analgesia after cesarean delivery. Studies comparing the 2 techniques are scarce, with conflicting results. This double-blind, randomized controlled trial aimed to compare bilateral ultrasound-guided TAP block with single-shot local anesthetic wound infiltration for analgesia after cesarean delivery performed under spinal anesthesia. We hypothesized that the TAP block would decrease postoperative cumulative fentanyl consumption at 24 hours. Eligible subjects were American Society of Anesthesiologists physical status II parturients with full-term singleton pregnancies undergoing elective cesarean delivery under spinal anesthesia. Exclusion criteria were: <19 years of age or >40 years of age; height <150 cm, weight <60 kg, body mass index ≥40 kg/m; contraindications to spinal anesthesia; history of recent opioid exposure; hypersensitivity to any of the drugs used in the study; significant cardiovascular, renal, or hepatic disease; and known fetal abnormalities. Eighty subjects were randomly allocated to 2 equal groups. In the infiltration group, participants received 15 mL of bupivacaine 0.25% in each side of the surgical wound (total 30 mL); and in the TAP group, participants received 20 mL of bupivacaine 0.25% bilaterally in the TAP block (total 40 mL). The TAP block and wound infiltration were performed by the primary investigator and the operating obstetrician, respectively. All participants received postoperative standard analgesia (ketorolac and paracetamol) and intravenous fentanyl via patient-controlled analgesia. Patients and outcome assessors were blinded to the study group. The primary outcome was the cumulative fentanyl consumption at 24 hours. Secondary outcomes were the time to the first postoperative fentanyl dose, cumulative fentanyl consumption at 2, 4, 6, and 12 hours, pain scores at rest and on movement at 2, 4, 6, 12, and 24 hours, the deepest level of

  18. Analgesic effect of ultrasound-guided transversus abdominis plane block after total abdominal hysterectomy: a randomized, double-blind, placebo-controlled trial.

    PubMed

    Røjskjaer, Jesper O; Gade, Erik; Kiel, Louise B; Lind, Morten N; Pedersen, Lars M; Kristensen, Billy B; Rasmussen, Yvonne H; Foss, Nicolai B

    2015-03-01

    To assess the effect of bilateral ultrasound-guided transversus abdominis plane block with ropivacaine compared with placebo as part of a multimodal analgesic regimen. A randomized, double-blind, placebo-controlled trial following the CONSORT criteria. Hvidovre University Hospital. Forty-six women scheduled for total abdominal hysterectomy. Women received either ropivacaine 0.75%, 20 mL (n = 24) or 0.9% saline, 20 mL (n = 24) in the transversus abdominis plane on each side. Primary outcome was the 24-h postoperative morphine consumption. Secondary outcomes were pain scores at rest and during coughing, postoperative nausea and vomiting at 1, 2, 4, 6, 8, and 24 h, and time to first mobilization. There was no difference in the mean 24-h postoperative morphine consumption between the two groups (p = 0.733). The ropivacaine group had significantly lower median pain scores at 1 h (p = 0.008) and 2 h (p = 0.027) postoperatively at rest and at 8 h (p = 0.028) during coughing. There was no significant difference in other secondary outcomes. There was no reduction in 24-h morphine consumption when using an ultrasound-guided transversus abdominis plane block in women undergoing total abdominal hysterectomy. As part of a multimodal regimen the transversus abdominis plane block showed some effect on pain scores at rest only in the early postoperative period. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.

  19. Analgesic efficacy of transversus abdominis plane block in neonates and early infants for colostomy and reversal of colostomy.

    PubMed

    Chen, Chee Kean; Teo, Shu Ching; Phui, Vui Eng; Saman, Mat Ariffin

    2015-01-01

    The application of ultrasound-guided transversus abdominis plane (TAP) block in paediatric population is gaining popularity among anaesthetists. We present a case series of ultrasound-guided TAP block in ten neonate and infants undergoing colostomy and reversal of stoma. Classical TAP as described by Hebbard was carried out and a maximum dosage of 1ml/kg of 0.25% levobupivacaine was injected. Pain score was assessed using Neonatal Infant Pain Scale for 24 hours. In all patients, the block was successful with minimal hemodynamic changes intraoperatively and no additional systemic analgesia was needed intraoperative and immediate postoperatively. Ultrasound-guided TAP block has an important role in providing safe and effective analgesia for colostomy creation and reversal of stoma surgeries in paediatric population.

  20. Ultrasound guided transversus abdominis plane vs surgeon administered intraoperative regional field infiltration with bupivacaine for early postoperative pain control in children undergoing open pyeloplasty.

    PubMed

    Lorenzo, Armando J; Lynch, Johanne; Matava, Clyde; El-Beheiry, Hossam; Hayes, Jason

    2014-07-01

    Regional analgesic techniques are commonly used in pediatric urology. Ultrasound guided transversus abdominis plane block has recently gained popularity. However, there is a paucity of information supporting a benefit over regional field infiltration. We present a parallel group, randomized, controlled trial evaluating ultrasound guided transversus abdominis plane block superiority over surgeon delivered regional field infiltration for children undergoing open pyeloplasty at a tertiary referral center. Following ethics board approval and registration, children 0 to 6 years old were recruited and randomized to undergo perioperative transversus abdominis plane block or regional field infiltration for early post-pyeloplasty pain control. General anesthetic delivery, surgical technique and postoperative analgesics were standardized. A blinded assessor regularly captured pain scores in the recovery room using the FLACC (Face, Legs, Activity, Cry, Consolability) scale. The primary outcome was the need for rescue morphine administration based on a FLACC score of 3 or higher. Two pediatric urologists performed 57 pyeloplasties during a 2.5-year period, enrolling 32 children (16 in each group, balanced for age and weight). There were statistically significant differences in the number of children requiring rescue morphine administration (13 of 16 receiving transversus abdominis plane block and 6 of 16 receiving regional field infiltration, p = 0.011), mean ± SD total morphine consumption (0.066 ± 0.051 vs 0.028 ± 0.040 mg/kg, p = 0.021) and mean ± SD pain scores (5 ± 5 vs 2 ± 3, p = 0.043) in the recovery room, in favor of surgeon administered regional field infiltration. No local anesthetic specific adverse events were noted. Ultrasound guided transversus abdominis plane block is not superior to regional field infiltration with bupivacaine as a strategy to minimize early opioid requirements following open pyeloplasty in children. Instead, our data suggest that

  1. Transversus abdominis plane (TAP) block in laparoscopic colorectal surgery improves postoperative pain management: a meta-analysis.

    PubMed

    Hain, E; Maggiori, L; Prost À la Denise, J; Panis, Y

    2018-04-01

    Transversus abdominis plane (TAP) block is a locoregional anaesthesia technique of growing interest in abdominal surgery. However, its efficacy following laparoscopic colorectal surgery is still debated. This meta-analysis aimed to assess the efficacy of TAP block after laparoscopic colorectal surgery. All comparative studies focusing on TAP block after laparoscopic colorectal surgery have been systematically identified through the MEDLINE database, reviewed and included. Meta-analysis was performed according to the Mantel-Haenszel method for random effects. End-points included postoperative opioid consumption, morbidity, time to first bowel movement and length of hospital stay. A total of 13 studies, including 7 randomized controlled trials, were included, comprising a total of 600 patients who underwent laparoscopic colorectal surgery with TAP block, compared with 762 patients without TAP block. Meta-analysis of these studies showed that TAP block was associated with a significantly reduced postoperative opioid consumption on the first day after surgery [weighted mean difference (WMD) -14.54 (-25.14; -3.94); P = 0.007] and a significantly shorter time to first bowel movement [WMD -0.53 (-0.61; -0.44); P < 0.001] but failed to show any impact on length of hospital stay [WMD -0.32 (-0.83; 0.20); P = 0.23] although no study considered length of stay as its primary outcome. Finally, TAP block was not associated with a significant increase in the postoperative overall complication rate [OR = 0.84 (0.62-1.14); P = 0.27]. Transversus abdominis plane (TAP) block in laparoscopic colorectal surgery improves postoperative opioid consumption and recovery of postoperative digestive function without any significant drawback. Colorectal Disease © 2018 The Association of Coloproctology of Great Britain and Ireland.

  2. Postoperative analgesic efficacy of single-shot and continuous transversus abdominis plane block after laparoscopic cholecystectomy: A randomized controlled clinical trial.

    PubMed

    Choi, Yun-Mi; Byeon, Gyeong-Jo; Park, Soon-Ji; Ok, Young-Min; Shin, Sang-Wook; Yang, Kwangho

    2017-06-01

    To compare the analgesic efficacy of ultrasound-guided single-shot and continuous transversus abdominis plane (TAP) block to that of IV-PCA in patients undergoing laparoscopic cholecystectomy. Prospective randomized controlled trial. Post-anesthesia care unit and General ward. 108 American Society of Anesthesiologist (ASA) physical status I-II patients undergoing laparoscopic cholecystectomy. Group A received IV-PCA; group B received both ultrasound-guided single-shot TAP block with 0.2% ropivacaine (20mL) and IV-PCA; and group C received continuous TAP block using an ultrasound-guidance-inserted indwelling catheter. In group C, infusion of 0.2% ropivacaine at a basal rate of 3mL/h, bolus dose of 4mL, and a lockout interval of 30min was maintained for 48h postoperatively. The primary outcome was evaluated analgesic efficacy using the numeric rating scale (NRS) for 48h postoperatively. Other outcomes included the number of patients requiring additional analgesics, patient satisfaction with postoperative pain control, and incidence of postoperative adverse events. Compared to other groups, group C had higher deep abdominal NRS at 1h postoperatively (P<0.05), and lower incidence of postoperative urinary retention (P<0.05). There were no significant intergroup differences in the number of patients requiring additional analgesics, and patient satisfaction with postoperative pain control. Compared to IV-PCA with or without single-shot TAP block, ultrasound-guided continuous TAP block provided similar analgesia in somatic pain and less analgesia in visceral pain. Moreover, the latter resulted in a lower incidence of postoperative urinary retention. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Comparison of ultrasound-guided posterior transversus abdominis plane block and lateral transversus abdominis plane block for postoperative pain management in patients undergoing cesarean section: a randomized double-blind clinical trial study.

    PubMed

    Faiz, Seyed Hamid Reza; Alebouyeh, Mahmoud Reza; Derakhshan, Pooya; Imani, Farnad; Rahimzadeh, Poupak; Ghaderi Ashtiani, Maryam

    2018-01-01

    Due to the importance of pain control after abdominal surgery, several methods such as transversus abdominis plane (TAP) block are used to reduce the pain after surgery. TAP blocks can be performed using various ultrasound-guided approaches. Two important approaches to do this are ultrasound-guided lateral and posterior approaches. This study aimed to compare the two approaches of ultrasound-guided lateral and posterior TAP blocks to control pain after cesarean section. In this double-blind clinical trial study, 76 patients scheduled for elective cesarean section were selected and randomly divided into two groups of 38 and underwent spinal anesthesia. For pain management after the surgery, one group underwent lateral TAP block and the other group underwent posterior TAP block using 20cc of ropivacaine 0.2% on both sides. Pain intensity was evaluated based on Numerical Analog Scale (NAS) at rest and when coughing, 2, 4, 6, 12, 24 and 36 hours after surgery. The pain at rest in the posterior group at all hours post surgery was lower than the lateral group, especially at 6, 12 and 24 hours after the surgery and the difference was statistically significant ( p =0.03, p <0.004, p =0.001). The results of this study show that ultrasound-guided posterior TAP block compared with the lateral TAP block was more effective in pain control after cesarean section.

  4. Rectus sheath and transversus abdominis plane blocks in children: a systematic review and meta-analysis of randomized trials.

    PubMed

    Hamill, James K; Rahiri, Jamie-Lee; Liley, Andrew; Hill, Andrew G

    2016-04-01

    The role of rectus sheath blocks (RSB) and transversus abdominis plane (TAP) blocks in pediatric surgery has not been well established. We aimed to determine if RSB and TAP blocks decrease postoperative pain and improve recovery in children. Duplicate searching of MEDLINE, EMBASE, Cochrane, Web of Science, and trial registries databases by two reviewers. Included were randomized trials in children on RSB or TAP block in abdominal operations, excluding inguinal procedures. Independent duplicate data extraction and quality assessment using a standardized form. Ten trials met inclusion criteria (n = 599), RSB in five and TAP block in five. A linear mixed effects model on patient level data from three trials showed nerve blocks lowered morphine requirements 6-8 h after surgery, -0.03 mg · kg(-1) (95% CI -0.05, -0.002). Pooled analysis of summary data showed nerve blocks lowered 0-10 scale pain scores immediately after the operation, -0.7 (95% CI -1.3, -0.1); lowered 4-16 scale pain scores, -2.0 (95% CI -2.3, -1.7); and delayed the time to first rescue analgesia, 17 min (95% CI 1.3, 33). Quality assessment showed some studies at moderate to high risk of bias. Abdominal wall blocks reduce pain and opiate use in children. We advise cautious interpretation of the results given the heterogeneity of studies. © 2016 John Wiley & Sons Ltd.

  5. The analgesic efficacy of ultrasound-guided transversus abdominis plane block on postoperative pain and morphine consumption in varicocelectomy.

    PubMed

    Ömür, Dilek; Oğuzalp, Hüseyin; Kiraz, Hasan A; Ekin, Serpil; Alan, Cabir; Ersay, Ahmet R; Hancı, Volkan

    2016-06-01

    To evaluate the analgesic effect of transversus abdominis plane (TAP) block administered before varicocele surgery. This study was completed at the Faculty of Medicine, Çanakkale Onsekiz Mart University, Çanakkale, Turkey, between January 2011 and April 2013. In a prospective, double blind, randomized, placebo controlled clinical study, 40 male patients scheduled for elective varicocele operations were randomized to group T (treatment group) or group C (controls). After receiving general anesthesia, group T received a TAP block using 20 mL 0.25% bupivacaine on the operation side, whereas group C received a control block using 20 mL 0.9% Sodium chloride. During the first 24 hours after surgery, the patient pain was evaluated using the visual analogue scale (VAS) at rest and while coughing. Postoperative patient controlled analgesia morphine consumption, VAS scores, and side effects were recorded. Of 34 patients, Group T (n=18) had significantly lower VAS pain scores than Group C (n=16) both at rest and while coughing. The total morphine consumed was  lower (7.7 ± 4.0) versus 21.6 ± 12.4 mg, p less than 0.001) in the 24 hours after surgery. As part of a multimodal analgesic regime after varicocelectomy surgery, morphine consumption and VAS pain scores were significantly lower among those receiving 20 mL 0.25% bupivacaine administered for a TAP block than among controls.

  6. A randomized trial comparing surgeon-administered intraoperative transversus abdominis plane block with anesthesiologist-administered transcutaneous block.

    PubMed

    Narasimhulu, D M; Scharfman, L; Minkoff, H; George, B; Homel, P; Tyagaraj, K

    2018-04-27

    Injection of local anesthetic into the transversus abdominis plane (TAP block) decreases systemic morphine requirements after abdominal surgery. We compared intraoperative surgeon-administered TAP block (surgical TAP) to anesthesiologist-administered transcutaneous ultrasound-guided TAP block (conventional TAP) for post-cesarean analgesia. We hypothesized that surgical TAP blocks would take less time to perform than conventional TAP blocks. We performed a randomized trial, recruiting 41 women undergoing cesarean delivery under neuraxial anesthesia, assigning them to either surgical TAP block (n=20) or conventional TAP block (n=21). Time taken to perform the block was the primary outcome, while postoperative pain scores and 24-hour opioid requirements were secondary outcomes. Student's t-test was used to compare block time and Kruskal-Wallis test opioid consumption and pain-scores. Time taken to perform the block (2.4 vs 12.1 min, P <0.001), and time spent in the operating room after delivery (55.3 vs 77.9 min, P <0.001) were significantly less for surgical TAP. The 24 h morphine consumption (P=0.17) and postoperative pain scores at 4, 8, 24 and 48 h were not significantly different between the groups. Surgical TAP blocks are feasible and less time consuming than conventional TAP blocks, while providing comparable analgesia after cesarean delivery. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. A randomised controlled trial investigating the analgesic efficacy of transversus abdominis plane block for adult laparoscopic appendicectomy.

    PubMed

    Tupper-Carey, Darell Alexander; Fathil, Shahridan Mohd; Tan, Yin Kiat Glenn; Kan, Yuk Man; Cheong, Chern Yuen; Siddiqui, Fahad Javaid; Assam, Pryseley Nkouibert

    2017-08-01

    We conducted a single-centre, prospective randomised clinical trial to investigate the analgesic efficacy of transversus abdominis plane (TAP) block in adult patients undergoing laparoscopic appendicectomy. Patients undergoing urgent laparoscopic appendicectomy under general anaesthesia alone (control group) and general anaesthesia supplemented by TAP block (TAP intervention group) were compared. All patients received a multimodal analgesia regime, which included postoperative morphine via a patient-controlled analgesia device. The primary endpoints were morphine consumption at 12 hours and 24 hours postoperatively. Secondary endpoints included pain scores, incidence of nausea and vomiting, and time to hospital discharge. A total of 58 patients were recruited, with 29 patients in each group. Mean postoperative morphine consumption at 12 hours (control group: 11.45 ± 7.64 mg, TAP intervention group: 9.79 ± 8.09 mg; p = 0.4264) and 24 hours (control group: 13.38 ± 8.72 mg, TAP intervention group: 11.31 ± 8.66 mg; p = 0.3686) for the control and TAP intervention groups were not statistically different. Secondary outcomes were also not different between the two groups. Length of stay in the post-anaesthesia care unit was significantly shorter for the TAP intervention group, with a trend toward faster hospital discharge being observed. TAP block, a regional anaesthetic procedure performed immediately prior to skin incision for laparoscopic appendicectomy, did not significantly improve postoperative analgesia outcomes. Copyright: © Singapore Medical Association

  8. Effect of adding dexamethasone to bupivacaine on transversus abdominis plane block for abdominal hysterectomy: A prospective randomized controlled trial

    PubMed Central

    Ammar, Amany S.; Mahmoud, Khaled M.

    2012-01-01

    Purpose: Different adjuvants have been used to improve the quality and increase the duration of local anesthetics during various nerve block techniques. The current study was aimed to evaluate the effect of adding dexamethasone to bupivacaine on the quality and duration of transversus abdominis plane (TAP) block. Methods: Sixty adult patients undergoing elective open abdominal hysterectomy were randomly allocated to receive TAP block using 20 mL of bupivacaine hydrochloride 0.25% + 2 mL saline 0.9% (control group, n=30) or 20 mL of bupivacaine hydrochloride 0.25% + 2 mL dexamethasone “8 mg” (dexamethasone group, n=30). The primary outcome was postoperative pain, as evaluated by visual analog scale (VAS) for pain scoring at 1, 2, 4, 12, 24 and 48 h postoperatively, whereas the secondary outcomes were time to first analgesia (TFA), morphine consumption and the occurrence of nausea, vomiting or somnolence. Results: The pain VAS score was significantly lower at the postoperative 2 h (4.9 vs. 28.1, P=0.01), 4 h (12.2 vs. 31.1, P=0.01) and 12 h (15.7 vs. 25.4, P=0.02). Furthermore, TFA was significantly longer in the dexamethasone group (459.8 vs. 325.4 min, P=0.002), with lesser morphine requirements in the postoperative 48 h (4.9 vs. 21.2 mg, P=0.003) and lower incidence of nausea and vomiting (6 vs. 14, P=0.03). No complications attributed to the block were recorded. Conclusion: Addition of dexamethasone to bupivacaine in TAP block prolonged the duration of the block and decreased the incidence of nausea and vomiting. PMID:23162395

  9. Chronological Changes in Ropivacaine Concentration and Analgesic Effects Between Transversus Abdominis Plane Block and Rectus Sheath Block.

    PubMed

    Murouchi, Takeshi; Iwasaki, Soshi; Yamakage, Michiaki

    2015-01-01

    Transversus abdominis plane block (TAPB) and rectus sheath block (RSB) are popular methods of controlling postoperative pain. Chronological changes in blood concentrations of local anesthetics have not been described, although a large amount of local anesthetic is required to block these compartments. We postulated that blood concentrations of anesthetics would peak earlier during TAPB than RSB (primary end point). Secondary end points were elapsed time from block until first postoperative rescue analgesia and affected dermatomes. This prospective, randomized study included 22 patients scheduled for laparoscopic ovarian surgery under general anesthesia. The patients were randomized to receive either a bilateral single-shot TAPB or a bilateral RSB (15 mL of 0.5% ropivacaine per side). Arterial blood was sampled 10, 20, 30, 45, 60, 90, and 120 minutes after ropivacaine administration. This trial was registered at the UMIN-Clinical Trials Registry (UMIN000012133) before patient recruitment. Arterial ropivacaine levels after block peaked earlier in the TAPB than in RSB [Tmax: 35 (12) vs 53 (16) minutes; P = 0.02], whereas peak ropivacaine concentrations did not significantly differ between the groups [Cmax: 1.83 (0.41) vs 1.79 (0.33) μg/mL; P = 0.54]. Peak ropivacaine concentrations exceeded 2.2 μg/mL in 1 and 2 patients in the RSB and TAPB groups, respectively, although symptoms of local anesthetic systemic toxicity were not evident in any of them. The median [interquartile range] duration of analgesia was significantly longer for TAPB than RSB (421 [335-536] vs 196 [168-277] minutes; P = 0.01). Peak ropivacaine concentrations were comparable during TAPB and RSB, but peaked earlier during TAPB. Although 150 mg of ropivacaine remained effective significantly longer during TAPB than RSB during laparoscopic surgery, this dose could cause local anesthetic systemic toxicity. The analgesic effects of blocks with less ropivacaine should be assessed.

  10. Effect of Transversus Abdominis Plane Block on Postoperative Pain after Colorectal Surgery: A Meta-Analysis of Randomized Controlled Trials.

    PubMed

    Liu, Lin; Xie, Yan-Hu; Zhang, Wei; Chai, Xiao-Qing

    2018-01-01

    To assess the analgesic efficacy of transversus abdominis plane (TAP) block in patients undergoing colorectal surgery (CRS). The databases of PubMed, ISI Web of Science, and Embase were searched, and randomized controlled studies (RCTs) that compared TAP block to control for relief of postoperative pain in patients who underwent CRS were included. Outcomes, including postoperative pain at rest and with movement, morphine use, postoperative nausea and vomiting, and the length of hospital stay, were analyzed using STATA software. The weighted mean differences (WMDs) with 95% confidence intervals (95% CIs) or relative risk with 95% CI were used to present the strength of associations. A total of 7 RCTs with 511 patients were included. The results of this study suggested that TAP block significantly relieved postoperative pain during postanesthetic recovery after CRS at rest and during movement (WMDs were -0.98 [95% CI -1.57 to -0.38] and -0.68 [-1.07 to -0.30], respectively), and also decreased pain intensity during movement 24 h after CRS (WMD: -0.57 [95% CI -1.06 to -0.08]). TAP block significantly reduced opioid consumption within 24 h when compared to controls, with a WMD of 15.66 (95% CI -23.93 to -7.39). However, TAP block did not shorten the length of hospital stay. TAP block was an effective approach for relief of postoperative pain and reduced postoperative consumption of morphine. More RCTs with large sample sizes are required to confirm these findings. © 2018 The Author(s) Published by S. Karger AG, Basel.

  11. "Transversus Abdominis Plane Blocks in Microsurgical Breast Reconstruction: Analysis of Pain, Narcotic Consumption, Length of Stay and Cost."

    PubMed

    Salibian, Ara A; Frey, Jordan D; Thanik, Vishal D; Karp, Nolan S; Choi, Mihye

    2018-06-02

    Transversus abdominis plane (TAP) blocks are increasingly being utilized in microvascular breast reconstruction. The implications of TAP blocks on specific reconstructive, patient and institutional outcomes remain to be fully elucidated. Patients undergoing abdominally-based microvascular breast reconstruction from 2015-2017 were reviewed. Length of stay, complications, narcotic consumption, donor-site pain and hospital expenses were compared between patients that did and those that did not receive TAP blocks with liposomal bupivacaine. Outcomes were subsequently compared in patients with elevated body mass index (BMI). Fifty patients (43.9%) received TAP blocks (27 [54.0%] under ultrasound guidance) and 64 patients (56.1%) did not. Patients with TAP blocks had significantly decreased oral and total narcotic consumption (p=0.0001 and p<0.0001, respectively) as well as significantly less donor-site pain (3.3 versus 4.3, p<0.0001). There was no significant difference in hospital expenses between the two cohorts ($21,531.53 versus $22,050.15 per patient, p=0.5659). Patients with BMI≥25 who received TAP blocks had a significantly decreased length of stay (3.8 versus 4.4 days, p=0.0345) as well as decreased narcotic consumption and postoperative pain compared to patients without TAP blocks. Patients with BMI<25 did not have a significant difference in postoperative pain, narcotic consumption or length of stay between the TAP versus no TAP block groups. TAP blocks with liposomal bupivacaine significantly reduce oral and total postoperative narcotic consumption as well as donor-site pain in all patients after abdominally-based microvascular breast reconstruction without increasing hospital expenses. TAP blocks additionally significantly decrease length of stay in patients with BMI≥25.

  12. Transversus abdominis plane block reduces postoperative pain intensity and analgesic consumption in elective cesarean delivery under general anesthesia.

    PubMed

    Eslamian, Laleh; Jalili, Zorvan; Jamal, Ashraf; Marsoosi, Vajiheh; Movafegh, Ali

    2012-06-01

    It is reported that following abdominal surgery, transversus abdominis plane (TAP) block can reduce postoperative pain. The primary outcome of this study was the evaluation of the efficacy of TAP block on pain intensity following cesarean delivery with Pfannenstiel incision. Fifty pregnant women were randomized blindly to receive either a TAP block with 15 ml 0.25% bupivacaine in both sides (group T, n = 25) or no blockade (group C, n = 25) at the end of the surgery, which was performed with a Pfannenstiel incision under general anesthesia. The pain intensity in the patients was assessed by a blinded investigator at the time of discharge from recovery and at 6, 12, and 24 h postoperatively, with a visual analogue scale (VAS) for pain. The women in the TAP block group had significantly lower VAS pain scores at rest and during coughing and consumed significantly less tramadol than the women in group C [50 mg (0-150) vs. 250 mg (0-400), P = 0.001]. There was a significantly longer time to the first request for analgesic in the TAP block group [210 min (0-300) vs. 30 min (10-180) in group C, P = 0.0001]. Two-sided TAP block with 0.25% bupivacaine in parturients who undergo cesarean section with a Pfannenstiel incision under general anesthesia can decrease postoperative pain and analgesic consumption. The time to the first analgesic rescue was longer in the parturients who received the TAP block.

  13. Pethidine efficacy in achieving the ultrasound-guided oblique subcostal transversus abdominis plane block in laparoscopic cholecystectomy: A prospective study.

    PubMed

    Breazu, Caius Mihai; Ciobanu, Lidia; Bartos, Adrian; Bodea, Raluca; Mircea, Petru Adrian; Ionescu, Daniela

    2017-02-21

    Pethidine is a synthetic opioid with local anesthetic properties. Our goal was to evaluate the analgesic efficacy of pethidine for achieving the ultrasound-guided oblique subcostal transversus abdominis plane (OSTAP) block in laparoscopic cholecystectomy. This prospective, double-blind study included 79 patients of physical status I and II according to American Society of Anesthesiologists, scheduled for elective laparoscopic cholecystectomy. The patients were randomly allocated into three groups, depending on the drug used to achieve preoperative bilateral OSTAP block: 1) OSTAP-Placebo (treated with normal saline); 2) OSTAP-Bupivacaine (treated with 0.25% bupivacaine); and 3) OSTAP-Pethidine (treated with 1% pethidine). The efficacy of pethidine in achieving the OSTAP block was analyzed using visual analog scale (VAS), intraoperative opioid dose, opioid consumption in post anesthesia care unit, and opioid consumption in the first 24 postoperative hours. The pain scores assessed by VAS at 0, 2, 4, 6, 12, and 24 hours were significantly lower in OSTAP-Pethidine than in OSTAP-Placebo group (p < 0.001). The mean intraoperative opioid consumption was significantly lower in OSTAP-Pethidine compared to OSTAP-Placebo group (150 versus 400 mg, p < 0.001), as well as the mean opioid consumption in the first 24 hours (20.4 versus 78 mg, p < 0.001). Comparing VAS assessment between OSTAP-Bupivacaine and OSTAP-Pethidine groups, statistically significant differences were observed only for the immediate postoperative pain assessment (0 hours), where lower values were observed in OSTAP-Pethidine group (p = 0.004). There were no statistically significant differences in the incidence of postoperative nausea and vomiting (p = 0.131) between the groups. The use of 1% pethidine can be an alternative to 0.25% bupivacaine in achieving OSTAP block for laparoscopic cholecystectomy.

  14. Postoperative analgesic efficiency of transversus abdominis plane block after ventral hernia repair: a prospective, randomized, controlled clinical trial.

    PubMed

    Chesov, Ion; Belîi, Adrian

    2017-10-01

    Effective postoperative analgesia is a key element in reducing postoperative morbidity, accelerating recovery and avoiding chronic postoperative pain. The aim of this study was to evaluate the effectiveness of ultrasound-guided Transversus Abdominis Plane (TAP) block, performed before surgical incision, in providing postoperative analgesia for patients undergoing open ventral hernia repair under general anaesthesia. Seventy elective patients scheduled for open ventral hernia repair surgery under general anaesthesia were divided randomly into two equal groups: Group I received bilateral TAP block performed before surgical incision (n = 35); Group II received systemic postoperative analgesia with parenteral opioid (morphine) alone (n = 35). Postoperatively pain scores at rest and with movement, total morphine consumption and opioid related side effects were recorded. Postoperative pain scores at rest and mobilization/cough were significantly higher in patients without TAP block (p < 0.05). Mean intraoperative fentanyl consumption was comparable between the two groups: 0.75 ± 0.31 mg in group I (TAP) and 0.86 ± 0.29 mg in group II (MO), p = 0.1299. Patients undergoing preincisional TAP block had reduced morphine requirements during the first 24 hours after surgery, compared to patients from group II, without TAP block (p = 0.0001). There was no difference in the incidence of opioid related side effects (nausea, vomiting) in the both groups during the first 24 postoperative hours. The use of preincisional ultrasound guided TAP block reduced the pain scores at rest and with movement/cough, opioid consumption and opioid-related side effects after ventral hernia repair when compared with opioid-only analgesia.

  15. [Efficiency of bupivacaine and association with dexmedetomidine in transversus abdominis plane block ultrasound guided in postoperative pain of abdominal surgery].

    PubMed

    Aksu, Recep; Patmano, Gülçin; Biçer, Cihangir; Emek, Ertan; Çoruh, Aliye Esmaoğlu

    We aimed to evaluate the effect of bupivacaine and dexmedetomidine added to bupivacaine used in tranversus abdominis plane (TAP) block on postoperative pain and patient satisfaction in patients undergoing lower abdominal surgery. Patients submitted to lower abdominal surgery were enrolled in the study. After anesthesia induction, ultrasound guided TAP block was performed. TAP block was obtained with 21mL 0.9% saline in Group C (n=31), 20mL 0.5% bupivacaine+1mL saline in Group B (n=31), and 20mL 0.5% bupivacaine+1mL dexmedetomidine (100μg) in Group BD (n=31). Visual analog scale scores were lower in Group BD compared to Group C, at all time points (p<0.05); it was lower in group BD than in group B at 10-24h. In Group B, it was lower than Group C at 2-8h (p<0.05). Total morphine consumption was lower in Group BD compared to other groups and lower in group B than in the controls (p<0.001). Patient satisfaction was higher in Group BD than in other groups and was higher in both study groups than in the controls (p<0.001). Nausea-vomiting scores, antiemetic requirement, or additional analgesic administration were not significant among groups (p>0.05). The addition of dexmedetomidine to bupivacaine on TAP block decreased postoperative pain scores and morphine consumption; it also increased patient satisfaction in patients undergoing lower abdominal surgery. Dexmedetomidine did not have any effect on nausea and vomiting score and antiemetic requirement. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  16. Comparison of bilateral transversus abdominis plane block and wound infiltration with bupivacaine for postoperative analgesia after cesarean delivery.

    PubMed

    Görkem, Ümit; Koçyiğit, Kamuran; Toğrul, Cihan; Güngör, Tayfun

    2017-03-15

    The study aimed to compare efficacy, safety, pain intensity and analgesic consumption in patients receiving either bilateral transversus abdominis plane (TAP) block or wound infiltration with bupivacaine after cesarean delivery (CD). A total of 216 parturient women undergoing CD under general anesthesia were randomly allocated into five groups: i) controls (group 1), ii) TAP placebo (group 2), iii) TAP (group 3), iv) wound infiltration placebo (group 4), and, v) wound infiltration (group 5). Pain intensity was assessed using a visual analogue scale (VAS). Analgesic consumptions were recorded by a blinded nurse at 6, 12, and 18 hours postoperatively. The baseline characteristics of the five groups were similar in terms of age, history of CD, and body mass indices (p>0.05). There were significant intergroup differences in VAS scores between all groups at the zero time-point (p=0.03), at the 6th hour (p=0.02), 12th hour (p=0.02), and at the 18th hour (p=0.02). Group 3 patients had lower pain scores and consumed less diclofenac than group 2 patients only within 12 hours postoperatively whereas pain intensity and analgesic consumption were not different between group 5 and group 4 patients. Group 5 patients received significantly less pethidine than group 4 and group 1 patients (p<0.001). TAP block provided better pain relief and less analgesic requirement than bupivacaine wound infiltration early after CD. Given the similar amounts of diclofenac but lower amounts of pethidine administered in the wound infiltration group, wound infiltration of bupivacaine seems promising in terms of reducing opioid use after CD under general anesthesia, especially when TAP block is not used.

  17. Transversus Abdominis Plane Blockade as Part of a Multimodal Postoperative Analgesia Plan in Patients Undergoing Radical Cystectomy.

    PubMed

    Matulewicz, Richard S; Patel, Mehul; Jordan, Brian J; Morano, Jacqueline; Frainey, Brendan; Bhanji, Yasin; Bux, Mahreen; Nader, Antoun; Kundu, Shilajit D; Meeks, Joshua J

    2018-04-26

    Radical cystectomy (RC) is a morbid procedure with frequent complications that may benefit from implementation of an enhanced recovery after surgery (ERAS) protocol. To examine the benefits of a multimodal analgesic plan that uses continuous transversus abdominis plane (TAP) blockade as part of an ERAS protocol after RC. A retrospective comparison of consecutive patients undergoing RC over a 4-year period was conducted. Patients were designated as having surgery either before or after implementation of an ERAS protocol. A major component of the ERAS protocol was a multi-modal analgesia plan with TAP blockade. Patient demographics, comorbidities, operative details, and outcomes, including days to flatus, bowel movement (BM), narcotic usage, and length of stay (LOS) were compared. In total, 171 patients were included: 100 pre-ERAS and 71 ERAS. There were no differences in age, smoking status, operative approach, or diversion type. The patients in the ERAS cohort were less likely to be male, had a higher median BMI, and more likely to have received neoadjuvant chemotherapy. Total and early postoperative narcotic use were lower in the ERAS cohort: 89 vs. 336 mg ( p  < 0.001) and 62 vs 203 mg ( p  = 0.001), respectively. The ERAS cohort had fewer days to flatus (3 vs. 4, p  < 0.001) and fewer days to bowel movement (4 vs. 5, p  < 0.001). Median LOS was shorter in the ERAS cohort (7 vs. 8.5d, p  = 0.001). There were no differences in complications or readmission rates between the two cohorts. TAP blockade as part of an ERAS multi-modal pain plan is associated with low narcotic usage, and significant improvement in time to flatus, BM, and LOS compared to traditional post-RC pain management.

  18. Postoperative Analgesia by a Transversus Abdominis Plane Block Using Different Concentrations of Ropivacaine for Abdominal Surgery: A Meta-Analysis.

    PubMed

    Sun, Ni; Wang, Shouyong; Ma, Pengpeng; Liu, Shuting; Shao, Aijie; Xiong, Ling

    2017-09-01

    Transversus abdominis plane block (TAPB) has been proven to be an effective means of postoperative anesthesia, but the optimum effective concentration of ropivacaine warrants further research. This study aimed to identify the optimal ropivacaine concentration of TAPB using a meta-analysis. This study consisted of a meta-analysis of randomized controlled trials (RCTs). We searched online databases, including PubMed, Embase, the Cochrane Database of Systematic Reviews, and Web of Science. RCTs investigating the 24-hour postoperative opioid consumption and the rest and dynamic pain scores 2, 12, and 24 hours after surgery were included in this analysis. We also assessed opioid-related side-effects and patient satisfaction 24 hours after surgery. Nineteen RCTs (1217 patients) were included in this meta-analysis, which showed that only TAPB with 0.375% and 0.5% ropivacaine was able to reduce opioid consumption 24 hours after surgery by weighted mean differences of -6.55 and -4.44 mg (morphine IV equivalents), respectively (P<0.05). A meta-regression analysis did not reveal an association between the local anesthetic dose (in mg), surgery, anesthesia, block timing, and the TAPB effect on opioid consumption. Ropivacaine concentrations of 0.375% and 0.5% reduced the 2-hour postoperative pain score and reduced the incidence of nausea and vomiting, but this analgesic effect disappeared at 12 and 24 hours. Only TAPB with 0.375% ropivacaine improved the degree of satisfaction 24 hours after surgery (weighted mean difference of 0.87 [0.08-1.66], P=0.03). In terms of efficacy and safety, the use of 0.375% ropivacaine for TAPB is preferred in the clinical work.

  19. [Ultrasound-guided Rectus Sheath Block vs Transversus Abdominis Plane Block in Children Undergoing Umbilical Hernia Repair].

    PubMed

    Torii, Naoko; Tachibana, Kazuya; Iwasaki, Mitsuo; Takeuchi, Muneyuki; Kinouchi, Keiko

    2016-06-01

    Although many reports describe the usefulness of the rectus sheath block (RSB) in the umbilical hernia repair, the efficacy of the transversus abdominis plane block (TAPB) is rarely reported. The purpose of this study was to compare the efficacy and technique of ultrasound-guided RSB and TAPB in children undergoing umbilical hernia repair. Thirty-four children younger than 12 years of age scheduled for umbilical hernia repair were enrolled in this prospective observer-blinded randomized clinical trial. They were randomly assigned either to RSB group (median age, 3.7 years) or TAPB group (median age, 3.8 years). After the induction of general anesthesia with sevoflurane, nitrous oxide, and oxygen children in both groups received regional anesthesia with 0.3 ml x kg(-1) of 0.25% ropivacaine on each side under ultrasound guidance. Hemodynamic changes at the skin incision, postoperative pain scores and parental satisfaction were recorded. Anesthesiologists rated the quality of ultrasound images and easiness of the block performance. The patients' demographics of the two groups were similar. There were no significant differences in the time needed for the block procedure, quality of ultrasound images and the change of the heart rate and blood pressure at the skin incision between the two groups. Postoperative pain score (immediately, 2 and 4 hours after the operation), need for rescue analgesia and satisfaction of the parents also did not differ. There were no major complications in the patients. TAPB provided comparable perioperative analgesia and easiness of block performance to RSB in the pediatric umbilical hernia repair.

  20. The efficacy of oblique subcostal transversus abdominis plane block in laparoscopic cholecystectomy – a prospective, placebo controlled study

    PubMed Central

    Breazu, Caius Mihai; Ciobanu, Lidia; Hadade, Adina; Bartos, Adrian; Mitre, Călin; Mircea, Petru Adrian; Ionescu, Daniela

    2016-01-01

    Introduction Pain control after a laparoscopic cholecystectomy can represent a challenge, considering the side effects due to standard analgesia methods. Recently the transversus abdominis plane block (TAP Block) has been used as a part of multimodal analgesia with promising results. The subcostal approach (OSTAP Block), a variant on the TAP block, produces reliable unilateral supraumbilical analgesia. This study evaluated the efficacy of the OSTAP block with bupivacaine in laparoscopic cholecystectomy compared with the placebo OSTAP block. Material and Methods Sixty ASA I/II adult patients listed for elective laparoscopic cholecystectomy were randomly allocated in one of two groups: Group A (OSTAP placebo) received preoperatively bilateral OSTAP block with sterile normal saline and Group B (OSTAP bupivacaine) received bilateral preoperatively OSTAP block with the same volumes of 0.25% bupivacaine. Twenty-four hours postoperative opioid consumption, the dose of opioid required during surgery, opioid dose in the recovery unit (PACU) and PACU length of stay were evaluated. The quality of analgesia was assessed by the Visual Analogue Scale (VAS) at specific interval hours during 24 h, at rest and with movement. Results The mean intraoperative opioid consumption showed a significant difference between the two groups, (385 ± 72.52 mg in group A vs 173.67 ± 48.60 mg in group B, p < 0.001). The mean 24 h opioid consumption showed a statistically significant difference between groups (32 ± 26.05 mg vs 79 ± 16.68 mg, p < 0.001). PACU length of stay was significantly lower for group B patients compared with group A patients (20.67 ± 11.27 min vs 41.67 ± 12.41 min, p < 0.001). The OSTAP bupivacaine group had a statistically significant lower pain score than the OSTAP placebo group at 0, 2, 4, 6, 12, 24 h, both at rest and with movement. No signs or symptoms of local anaesthetic systemic toxicity or other complications were detected. Conclusion OSTAP block with

  1. Comparison of Transversus Abdominis Plane Infiltration with Liposomal Bupivacaine versus Continuous Epidural Analgesia versus Intravenous Opioid Analgesia.

    PubMed

    Ayad, Sabry; Babazade, Rovnat; Elsharkawy, Hesham; Nadar, Vinayak; Lokhande, Chetan; Makarova, Natalya; Khanna, Rashi; Sessler, Daniel I; Turan, Alparslan

    2016-01-01

    Epidural analgesia is considered the standard of care but cannot be provided to all patients Liposomal bupivacaine has been approved for field blocks such as transversus abdominis plane (TAP) blocks but has not been clinically compared against other modalities. In this retrospective propensity matched cohort study we thus tested the primary hypothesis that TAP infiltration are noninferior (not worse) to continuous epidural analgesia and superior (better) to intravenous opioid analgesia in patients recovering from major lower abdominal surgery. 318 patients were propensity matched on 18 potential factors among three groups (106 per group): 1) TAP infiltration with bupivacaine liposome; 2) continuous Epidural analgesia with plain bupivacaine; and; 3) intravenous patient-controlled analgesia (IV PCA). We claimed TAP noninferior (not worse) over Epidural if TAP was noninferior (not worse) on total morphine-equivalent opioid and time-weighted average pain score (10-point scale) within first 72 hours after surgery with noninferiority deltas of 1 (10-point scale) for pain and an increase less of 20% in the mean morphine equivalent opioid consumption. We claimed TAP or Epidural groups superior (better) over IV PCA if TAP or Epidural was superior on opioid consumption and at least noninferior on pain outcome. Multivariable linear regressions within the propensity-matched cohorts were used to model total morphine-equivalent opioid dose and time-weighted average pain score within first 72 hours after surgery; joint hypothesis framework was used for formal testing. TAP infiltration were noninferior to Epidural on both primary outcomes (p<0.001). TAP infiltration were noninferior to IV PCA on pain scores (p = 0.001) but we did not find superiority on opioid consumption (p = 0.37). We did not find noninferiority of Epidural over IV PCA on pain scores (P = 0.13) and nor did we find superiority on opioid consumption (P = 0.98). TAP infiltration with liposomal bupivacaine and

  2. [Post-operative pain after ultrasound transversus abdominis plane block versus trocar site infiltration in laparoscopic nephrectomy: a prospective study].

    PubMed

    Araújo, Ana M; Guimarães, Joana; Nunes, Catarina S; Couto, Paula S; Amadeu, Eduarda

    Transversus abdominis plane (TAP) block is useful in reducing post-operative pain in laparoscopic nephrectomy compared to placebo. The purpose of this work is to compare post-operative pain and recovery after TAP block or trocar site infiltration (TSI) in this surgery. A prospective, single blinded study on patients scheduled for laparoscopic nephrectomy. Patients were assigned to two groups: TSI Group: trocar site infiltration at the end of surgery; TAP Group: unilateral ultrasound-guided TAP block after induction. Sevoflurane and remifentanil, in a target controlled infusion mode, were used for maintenance of general anesthesia. Before the end of surgery paracetamol, tramadol and morphine were administered. Visual analogue scale (VAS 0-100mm) at rest and with cough was applied in three moments: in recovery room (T1 at admission and T2 before discharge) and 24h after surgery (T3). Pain scores with incentive spirometer were also evaluated at T3. In recovery, morphine was administered as a rescue drug whenever VAS>30mm. Time to oral intake, chair sitting, ambulation and length of hospital stay were evaluated 24h after surgery. Student's t-test and Chi-square test, and linear regression models. A p-value<0.05 was considered significant. Data are presented as mean (SD). Forty patients were enrolled in the study. The primary outcome variable, VAS pain scores did not show a statistical significant difference between groups (p>0.05). VAS at rest (TAP vs. TSI groups) was: T1=33±29 vs. 39±32, T2=10±9 vs. 17±18 and T3=7±12 vs. 10±18. VAS with cough (TAP vs. TSI groups) was: T1=51±34 vs. 45±32, T2=24±24 vs. 33±23 and T3=20±23 vs. 23±23. VAS with incentive spirometer (TAP vs. TSI groups) was: T3=21±27 vs. 21±25. Intraoperative remifentanil consumption was similar between TAP (0.16±0.07mcg.kg -1 .min -1 ) and TSI (0.18±0.9mcg.kg -1 .min -1 ) groups. There were no differences in opioid consumption between TAP (4.4±3.49mg) and TSI (6.87±4.83mg) groups during

  3. The efficacy of oblique subcostal transversus abdominis plane block in laparoscopic cholecystectomy - a prospective, placebo controlled study.

    PubMed

    Breazu, Caius Mihai; Ciobanu, Lidia; Hadade, Adina; Bartos, Adrian; Mitre, Călin; Mircea, Petru Adrian; Ionescu, Daniela

    2016-04-01

    Pain control after a laparoscopic cholecystectomy can represent a challenge, considering the side effects due to standard analgesia methods. Recently the transversus abdominis plane block (TAP Block) has been used as a part of multimodal analgesia with promising results. The subcostal approach (OSTAP Block), a variant on the TAP block, produces reliable unilateral supraumbilical analgesia. This study evaluated the efficacy of the OSTAP block with bupivacaine in laparoscopic cholecystectomy compared with the placebo OSTAP block. Sixty ASA I/II adult patients listed for elective laparoscopic cholecystectomy were randomly allocated in one of two groups: Group A (OSTAP placebo) received preoperatively bilateral OSTAP block with sterile normal saline and Group B (OSTAP bupivacaine) received bilateral preoperatively OSTAP block with the same volumes of 0.25% bupivacaine. Twenty-four hours postoperative opioid consumption, the dose of opioid required during surgery, opioid dose in the recovery unit (PACU) and PACU length of stay were evaluated. The quality of analgesia was assessed by the Visual Analogue Scale (VAS) at specific interval hours during 24 h, at rest and with movement. The mean intraoperative opioid consumption showed a significant difference between the two groups, (385 ± 72.52 mg in group A vs 173.67 ± 48.60 mg in group B, p < 0.001). The mean 24 h opioid consumption showed a statistically significant difference between groups (32 ± 26.05 mg vs 79 ± 16.68 mg, p < 0.001). PACU length of stay was significantly lower for group B patients compared with group A patients (20.67 ± 11.27 min vs 41.67 ± 12.41 min, p < 0.001). The OSTAP bupivacaine group had a statistically significant lower pain score than the OSTAP placebo group at 0, 2, 4, 6, 12, 24 h, both at rest and with movement. No signs or symptoms of local anaesthetic systemic toxicity or other complications were detected. OSTAP block with bupivacaine 0.25% can provide effective analgesia up to 24

  4. An anatomical study of the transversus abdominis plane block: location of the lumbar triangle of Petit and adjacent nerves.

    PubMed

    Jankovic, Zorica B; du Feu, Frances M; McConnell, Patricia

    2009-09-01

    The transversus abdominis plane (TAP) block is a new technique for providing analgesia to the anterior abdominal wall. Most previous studies have used the lumbar triangle of Petit as a landmark for the block. In this cadaveric study, we determined the exact position and size of the lumbar triangle of Petit and identified the nerves affected by the TAP block. The position of the lumbar triangle of Petit was assessed unilaterally in 26 cadaveric specimens relative to reliably palpable surface landmarks. In addition, a series of dissections were performed to explore the course of the nerves blocked by the TAP. The mean distance from the midaxillary line along the iliac crest to the center of the base of the lumbar triangle of Petit at the level of the subcutaneous tissue and over the skin surface was 6.9 cm (range, 4.5-9.2 cm) and 9.3 cm (range, 4-15.1 cm), respectively. The center of the lumbar triangle of Petit was 1.4 cm above the iliac crest. The depth of the TAP at the lumbar triangle of Petit position was 0.5-4 cm and at the midaxillary line it was 0.5-2 cm. The average size of the lumbar triangle of Petit was 2.3 cm x 3.3 cm x 2.2 cm, with an average area of 3.63 +/- 1.93 cm2. The three cadaveric specimens we explored showed the nerves blocked by TAP passed lateral to the triangle. An incidental finding was that in 66% of specimens the lumbar triangle of Petit contained small branches of the subcostal artery. The lumbar triangles of Petit found in the specimens in this study were more posterior than the literature suggests. The position of the lumbar triangle of Petit varies largely and the size is relatively small. The relevant nerves to be blocked had not entered the TAP in the specimens in this study at the point of the lumbar triangle of Petit. At the midaxillary line, however, all the nerves were in the TAP.

  5. Ultrasound-Guided Out-of-Plane vs. In-Plane Interscalene Catheters: A Randomized, Prospective Study.

    PubMed

    Schwenk, Eric S; Gandhi, Kishor; Baratta, Jaime L; Torjman, Marc; Epstein, Richard H; Chung, Jaeyoon; Vaghari, Benjamin A; Beausang, David; Bojaxhi, Elird; Grady, Bernadette

    2015-12-01

    Continuous interscalene blocks provide excellent analgesia after shoulder surgery. Although the safety of the ultrasound-guided in-plane approach has been touted, technical and patient factors can limit this approach. We developed a caudad-to-cephalad out-of-plane approach and hypothesized that it would decrease pain ratings due to better catheter alignment with the brachial plexus compared to the in-plane technique in a randomized, controlled study. To compare an out-of-plane interscalene catheter technique to the in-plane technique in a randomized clinical trial. Eighty-four patients undergoing open shoulder surgery were randomized to either the in-plane or out-of-plane ultrasound-guided continuous interscalene technique. The primary outcome was VAS pain rating at 24 hours. Secondary outcomes included pain ratings in the recovery room and at 48 hours, morphine consumption, the incidence of catheter dislodgments, procedure time, and block difficulty. Procedural data and all pain ratings were collected by blinded observers. There were no differences in the primary outcome of median VAS pain rating at 24 hours between the out-of-plane and in-plane groups (1.50; IQR, [0 - 4.38] vs. 1.25; IQR, [0 - 3.75]; P = 0.57). There were also no differences, respectively, between out-of-plane and in-plane median PACU pain ratings (1.0; IQR, [0 - 3.5] vs. 0.25; IQR, [0 - 2.5]; P = 0.08) and median 48-hour pain ratings (1.25; IQR, [1.25 - 2.63] vs. 0.50; IQR, [0 - 1.88]; P = 0.30). There were no differences in any other secondary endpoint. Our out-of-plane technique did not provide superior analgesia to the in-plane technique. It did not increase the number of complications. Our technique is an acceptable alternative in situations where the in-plane technique is difficult to perform.

  6. Transversus Abdominis Plane Block Versus Caudal Epidural for Lower Abdominal Surgery in Children: A Double-Blinded Randomized Controlled Trial.

    PubMed

    Bryskin, Robert B; Londergan, Bevan; Wheatley, Rebekah; Heng, Renee; Lewis, Marjorie; Barraza, Mark; Mercer, Erica; Ye, Gang

    2015-08-01

    Transversus abdominis plane block (TAPB) has emerged as a safe and effective regional anesthesia technique for providing postoperative lower abdominal analgesia. Complications associated with TAPB are rare and pose a lower overall risk to the patient receiving a TAPB versus a caudal block, which is considered the gold standard for pediatric lower abdominal regional anesthesia. Our study hypothesis was that TAPB would initially be equivalent to caudal block in providing postoperative pain control but would also show improved pain relief beyond the anticipated caudal duration. This study was a double-blinded randomized controlled trial. Forty-five children between the ages of 1 and 9 undergoing bilateral ureteral reimplantation surgery through a low transverse incision were enrolled. Narcotic requirement, pain scores (FLACC/Wong-Baker FACES), episodes of emesis, and antispasmodic requirement were recorded in the postanesthesia care unit (PACU) and at 6-hour intervals for 24 hours from the time of block placement. Our protocol used a multimodal approach toward pain management in all children, including randomized regional technique, scheduled ketorolac, morphine as needed, and the antispasmodic, oxybutynin, as needed. Morphine requirement showed no statistical difference during the initial 12 hours (all P ≥ 0.68 at PACU, 6 and 12 hours). However, at 24 hours those patients randomized to receive the TAPB required less cumulative morphine than the caudal group (0.05 mg/kg ± 0.06 vs 0.09 mg/kg ± 0.07, P = 0.03). There was a trend toward fewer episodes of emesis in the TAPB group which reached statistical significance at 18 and 24 hours (6 vs 1 episodes, P = 0.03; and 9 vs 2 episodes, P = 0.02). Pain scores (0-10) were higher in the TAPB group in the PACU (3.46 ± 2.69 vs 1.71 ± 2.1, P = 0.02), but there were no significant differences at all subsequent time points (all P ≥ 0.10). The TAPB group also had a higher requirement for the bladder antispasmodic oxybutynin

  7. Continuous Transversus Abdominis Plane Nerve Blocks: Does Varying Local Anesthetic Delivery Method-Automatic Repeated Bolus Versus Continuous Basal Infusion-Influence the Extent of Sensation to Cold?: A Randomized, Triple-Masked, Crossover Study in Volunteers.

    PubMed

    Khatibi, Bahareh; Said, Engy T; Sztain, Jacklynn F; Monahan, Amanda M; Gabriel, Rodney A; Furnish, Timothy J; Tran, Johnathan T; Donohue, Michael C; Ilfeld, Brian M

    2017-04-01

    It remains unknown whether continuous or scheduled intermittent bolus local anesthetic administration is preferable for transversus abdominis plane (TAP) catheters. We therefore tested the hypothesis that when using TAP catheters, providing local anesthetic in repeated bolus doses increases the cephalad-caudad cutaneous effects compared with a basal-only infusion. Bilateral TAP catheters (posterior approach) were inserted in 24 healthy volunteers followed by ropivacaine 2 mg/mL administration for a total of 6 hours. The right side was randomly assigned to either a basal infusion (8 mL/h) or bolus doses (24 mL administered every 3 hours for a total of 2 bolus doses) in a double-masked manner. The left side received the alternate treatment. The primary end point was the extent of sensory deficit as measured by cool roller along the axillary line at hour 6 (6 hours after the local anesthetic administration was initiated). Secondary end points included the extent of sensory deficit as measured by cool roller and Von Frey filaments along the axillary line and along a transverse line at the level of the anterior superior iliac spine at hours 0 to 6. Although there were statistically significant differences between treatments within the earlier part of the administration period, by hour 6 the difference in extent of sensory deficit to cold failed to reach statistical significance along the axillary line (mean = 0.9 cm; SD = 6.8; 95% confidence interval -2.0 to 3.8; P = .515) and transverse line (mean = 2.5 cm; SD = 10.1; 95% confidence interval -1.8 to 6.8; P = .244). Although the difference between treatments was statistically significant at various early time points for the horizontal, vertical, and estimated area measurements of both cold and mechanical pressure sensory deficits, no comparison remained statistically significant by hour 6. No evidence was found in this study involving healthy volunteers to support the hypothesis that changing the local anesthetic

  8. The effect of morphine added to bupivacaine in ultrasound guided transversus abdominis plane (TAP) block for postoperative analgesia following lower abdominal cancer surgery, a randomized controlled study.

    PubMed

    El Sherif, Fatma Adel; Mohamed, Sahar Abdel-Baky; Kamal, Shereen Mamdouh

    2017-06-01

    Transversus abdominis plane (TAP) block used for management of surgical abdominal pain by injecting local anesthetics into the plane between the internal oblique and transversus abdominis muscles. We aimed to explore the effect of adding morphine to bupivacaine in ultrasound guided TAP-block in patients undergoing lower abdominal cancer surgery. Randomized, double-blind, prospective study. Clinical trial identifier: NCT02566096. Academic medical center. Sixty patients were enrolled in this study after ethical committee approval. Patients divided into 2 groups (30 each): Bupivacaine group (GB): given ultrasound guided TAP-block 20ml 0.5% bupivacaine diluted in 20ml saline; Morphine group (GM): given ultrasound guided TAP-block with 20ml 0.5% bupivacaine+10mg morphine sulphate diluted in 20ml saline. Patients were observed for total morphine consumption, time for first request of rescue analgesia, sedation scores, hemodynamics and side effects for 24h postoperatively. Morphine added to bupivacaine in TAP block compared to bupivacaine alone reduced total morphine consumption (5.33±1.28mg) (10.70±3.09mg) respectively (p<0.001), prolonged the time to first request of analgesia (10.40±4.96h) (6.97±3.26h) respectively (p<0.008), with a statistically significant decrease in (VAS-M) in GM compared with GB at 12h postoperatively (p<0.002). No significant differences in hemodynamics, respiratory rate, oxygen saturation, sedation score, and side effects except for nausea were observed (p>0.05). Addition of morphine to bupivacaine in TAP block is effective method for pain management in patients undergoing major abdominal cancer surgery without serious side effects. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Effectiveness of ultrasound-guided transversus abdominis plane block and rectus sheath block in pain control and recovery after gynecological transumbilical single-incision laparoscopic surgery.

    PubMed

    Mugita, M; Kawahara, R; Tamai, Y; Yamasaki, K; Okuno, S; Hanada, R; Inaoka, M; Funato, T

    2014-01-01

    To evaluate the effectiveness of ultrasound-guided transversus abdominis plane (TAP) and rectus sheath (RS) blocks in pain management and recovery after gynecological single-incision laparoscopic surgery (SILS). Abilateral TAP block (Group A, n = 9), bilateral TAP and RS blocks (Group B, n = 10), and a bilateral RS block (Group C, n = 9) with 40 ml ropivacaine per patient were conducted in 28 patients undergoing SILS for ovarian tumors. A pain score and walking distance in a 6-minute walk test (6MWT) were examined. Pain scores were significantly lower on postoperative day (POD) 3 than on POD 1 in Groups B (p = 0.03) and C (p = 0.02). The walking distance on POD 3 was comparable with that before surgery in Group C (p = 0.75), but shorter in Groups A (p = 0.004) and B (p = 0.02). The RS block alone was the most effective in relieving pain and accelerating general recovery after gynecological SILS.

  10. Analgesic effects of ultrasound-guided transverse abdominis plane block using different volumes and concentrations of local analgesics after laparoscopic cholecystectomy.

    PubMed

    Şahin, Ayça Sultan; Ay, Necmiye; Şahbaz, Nuri Alper; Akay, Mehlika Kocabaş; Demiraran, Yavuz; Derbent, Abdurrahim

    2017-02-01

    Objective To evaluate the effects of an ultrasound-guided transverse abdominis plane (US-TAP) block used for postoperative pain relief by comparing the efficacy of two different volumes/concentrations of the local anaesthetic bupivacaine in patients undergoing laparoscopic cholecystectomies. Methods This randomized study enrolled patients undergoing laparoscopic cholecystectomies. They were randomized to two groups: group A received a 20 ml US-TAP block (50 mg bupivacaine +10 ml saline solution) and group B received a 30 ml US-TAP block (50 mg bupivacaine + 20 ml saline solution). The intraoperative consumption of remifentanil, the requirement for postoperative rescue analgesics, patient satisfaction scores, postoperative complications, and postoperative pain as measured by a visual analogue scale at 20 min, 12 h, and 24 h were recorded. Results A total of 60 patients enrolled in the study. There were no differences between the two groups with respect to demographic characteristics, duration of anaesthesia and patient satisfaction scores. The intraoperative consumption of remifentanil, postoperative VAS scores (20 min, 12 h and 24 h) and the requirement for postoperative analgesics were all significantly lower in group B who received a larger volume but a lower concentration of local anaesthetic solution compared with group A. Conclusion A US-TAP block can form part of a balanced postoperative analgesic regimen following laparoscopic cholecystectomy.

  11. Clinical safety and effectiveness of transversus abdominis plane (TAP) block in post-operative analgesia: a systematic review and meta-analysis.

    PubMed

    Ma, Ning; Duncan, Joanna K; Scarfe, Anje J; Schuhmann, Susanne; Cameron, Alun L

    2017-06-01

    Transversus abdominis plane (TAP) blocks can provide analgesia postoperatively for a range of surgeries. Abundant clinical trials have assessed TAP block showing positive analgesic effects. This systematic review assesses safety and effectiveness outcomes of TAP block in all clinical settings, comparing with both active (standard care) and inactive (placebo) comparators. PubMed, EMBASE, The Cochrane Library and the University of York CRD databases were searched. RCTs were screened for their eligibility and assessed for risk of bias. Meta-analyses were performed on available data. TAP block showed an equivalent safety profile to all comparators in the incidence of nausea (OR = 1.07) and vomiting (OR = 0.81). TAP block was more effective in reducing morphine consumption [MD = 13.05, 95% CI (8.33, 51.23)] and in delaying time to first analgesic request [MD = 123.49, 95% CI (48.59, 198.39)]. Postoperative pain within 24 h was reduced or at least equivalent in TAP block compared to its comparators. Therefore, TAP block is a safe and effective procedure compared to standard care, placebo and other analgesic techniques. Further research is warranted to investigate whether the TAP block technique can be improved by optimizing dose and technique-related factors.

  12. Levobupivacaine-dextran mixture for transversus abdominis plane block and rectus sheath block in patients undergoing laparoscopic colectomy: a randomised controlled trial.

    PubMed

    Hamada, T; Tsuchiya, M; Mizutani, K; Takahashi, R; Muguruma, K; Maeda, K; Ueda, W; Nishikawa, K

    2016-04-01

    We performed a randomised controlled double-blinded study of patients having laparoscopic colectomy with bilateral transversus abdominis plane block plus rectus sheath block, comparing a control group receiving 80 ml levobupivacaine 0.2% in saline with a dextran group receiving 80 ml levobupivacaine 0.2% in 8% low-molecular weight dextran. Twenty-seven patients were studied in each group. The mean (SD) maximum plasma concentration of levobupivacaine in the control group (1410 (322) ng.ml(-1) ) was higher than the dextran group (1141 (287) ng.ml(-1) ; p = 0.004), and was reached more quickly (50.6 (30.2) min vs 73.2 (24.6) min; p = 0.006). The area under the plasma concentration-time curve from 0 min to 240 min in the control group (229,124 (87,254) ng.min.ml(-1) ) was larger than in the dextran group (172,484 (50,502) ng.min.ml(-1) ; p = 0.007). The median (IQR [range]) of the summated numerical pain rating score at rest during the first postoperative 24 h in the control group (16 (9-20 [3-31]) was higher than in the dextran group (8 (2-11 [0-18]); p = 0.0001). In this study, adding dextran to levobupivacaine decreased the risk of levobupivacaine toxicity while providing better analgesia. © 2016 The Association of Anaesthetists of Great Britain and Ireland.

  13. Local wound infiltration plus transversus abdominis plane (TAP) block versus local wound infiltration in laparoscopic colorectal surgery and ERAS program.

    PubMed

    Pedrazzani, Corrado; Menestrina, Nicola; Moro, Margherita; Brazzo, Gianluca; Mantovani, Guido; Polati, Enrico; Guglielmi, Alfredo

    2016-11-01

    Few data are available on TAP block in laparoscopic colorectal surgery and ERAS program. The aim of this prospective study was to evaluate local wound infiltration plus TAP block compared to local wound infiltration in the management of postoperative pain, nausea and vomiting, ileus and use of opioids in the context of laparoscopic colorectal surgery and ERAS program. From March 2014 to March 2015, 48 patients were treated by laparoscopic resection and ERAS program for colorectal cancer and diverticular disease at the Division of General and Hepatobiliary Surgery, University of Verona Hospital Trust. Among these, 24 patients received local wound infiltration plus TAP block (TAP block group) and 24 patients received local wound infiltration (control group). No differences were observed in baseline patient characteristics, clinical variables and surgical procedures between the two groups. Local wound infiltration plus TAP block allowed to achieve pain control despite a reduced use of opioid analgesics (P = 0.009). The adoption of TAP block resulted beneficial on the prevention of postoperative nausea (P = 0.002) and improvement of essential outcomes of ERAS program as recovery of bowel function (P = 0.005), urinary catheter removal (P = 0.003) and capability to tolerate oral diet (P = 0.027). TAP block plus local wound infiltration in the setting of laparoscopic colorectal surgery and ERAS program guarantees a reduced use of opioid analgesics and good pain control allowing the improvement of essential items of enhanced recovery pathways.

  14. Comparison of efficacy and safety of lateral-to-medial continuous transversus abdominis plane block with thoracic epidural analgesia in patients undergoing abdominal surgery: A randomised, open-label feasibility study.

    PubMed

    Ganapathy, Sugantha; Sondekoppam, Rakesh V; Terlecki, Magdalena; Brookes, Jonathan; Das Adhikary, Sanjib; Subramanian, Lakshmimathy

    2015-11-01

    We recently described a lateral-to-medial approach for transversus abdominis plane (LM-TAP) block, which may permit preoperative initiation of the block. Our objective was to evaluate the feasibility of continuous LM-TAP blocks in clinical practice in comparison with thoracic epidural analgesia (TEA). A randomised, open-label study. University Hospital, London Health Sciences Centre, London, Ontario, Canada from July 2008 to August 2012. Fifty adult patients undergoing open abdominal surgery via laparotomy were allocated randomly to receive preoperative catheter-congruent TEA or ultrasound-guided continuous bilateral LM-TAP block for 72 h postoperatively. Reasons for noninclusion were American Society of Anesthesiologists' physical status more than 4, known allergy to study drugs, chronic pain/opioid dependence, spinal abnormalities or psychiatric illness. In the TEA group (n = 24), patient-controlled epidural analgesia was maintained using bupivacaine 0.1% with hydromorphone 10 μg ml⁻¹ after establishment of the initial block. In the LM-TAP group (n = 26), ultrasound-guided LM-TAP catheters were inserted on each side preoperatively after a bolus of 30 ml of ropivacaine 0.5% (20 ml subcostal and 10 ml subumbilical injections on both sides). Analgesia was maintained with an infusion of ropivacaine 0.35% at a rate of 2 to 2.5 ml h⁻¹ through each catheter, along with rescue intravenous patient-controlled analgesia. The primary outcome was pain score on coughing 24 h after the end of surgery. Secondary outcomes were pain scores from 24 to 72 h, intraoperative and postoperative opioid consumption, time to onset of bowel movement and side effect profiles. Mean [95% confidence interval (95% CI)] pain scores at rest ranged from 1. 7 (0.9 to 2.5) to 2.3 (1.1 to 3.4) in TEA vs. 1.5 (0.7 to 2.2) to 2.2 (1.3 to 3.0) in LM-TAP (P = 0.829). The dynamic pain scores ranged from 2.9 (1.5 to 4.4) to 3.8 (2.8 to 4.8) in TEA vs. 3.3 (2.4 to 4

  15. Analgesic efficacy of ultrasound guided transversus abdominis plane block versus local anesthetic infiltration in adult patients undergoing single incision laparoscopic cholecystectomy: A randomized controlled trial.

    PubMed

    Bava, Ejas P; Ramachandran, Rashmi; Rewari, Vimi; Chandralekha; Bansal, Virinder Kumar; Trikha, Anjan

    2016-01-01

    Transversus abdominis plane (TAP) block has been used to provide intra- and post-operative analgesia with single incision laparoscopic (SIL) bariatric and gynecological surgery with mixed results. Its efficacy in providing analgesia for SIL cholecystectomy (SILC) via the same approach remains unexplored. The primary objective of our study was to compare the efficacy of bilateral TAP block with local anesthetic infiltration for perioperative analgesia in patients undergoing SILC. This was a prospective, randomized, controlled, double-blinded trial performed in a tertiary care hospital. Forty-two patients undergoing SILC were randomized to receive either ultrasound-guided (USG) bilateral mid-axillary TAP blocks with 0.375% ropivacaine or local anesthetic infiltration of the port site. The primary outcome measure was the requirement of morphine in the first 24 h postoperatively. The data were analyzed using t -test, Mann-Whitney test or Chi-square test. The 24 h morphine requirement (mean ± standard deviation) was 34.57 ± 14.64 mg in TAP group and 32.76 ± 14.34 mg in local infiltration group ( P = 0.688). The number of patients requiring intraoperative supplemental fentanyl in TAP group was 8 and in local infiltration group was 16 ( P = 0.028). The visual analog scale scores at rest and on coughing were significantly higher in the local infiltration group in the immediate postoperative period ( P = 0.034 and P = 0.007, respectively). USG bilateral TAP blocks were not effective in decreasing 24 h morphine requirement as compared to local anesthetic infiltration in patients undergoing SILC although it provided some analgesic benefit intraoperatively and in the initial 4 h postoperatively. Hence, the benefits of TAP blocks are not worth the effort and time spent for administering them for this surgery.

  16. Ultrasound-guided rectus sheath and transversus abdominis plane blocks for perioperative analgesia in upper abdominal surgery: A randomized controlled study.

    PubMed

    Abdelsalam, Khaled; Mohamdin, O W

    2016-01-01

    Regional anesthetic techniques can be used to alleviate postoperative pain in patients undergoing major upper abdominal surgery. Our aim was to evaluate the efficacy of bilateral ultrasound (US)-guided rectus sheath (RS) and transversus abdominis plane (TAP) blocks for better perioperative analgesia. It is a prospective, observer-blinded, randomized clinical study. 40 eligible patients undergoing elective liver resection or Whipple procedure were included. All patients received a standardized anesthetic technique. Group 1 (n = 20) received preincisional US-guided bilateral RS and TAP blocks using 20 ml volume of bupivacaine 0.25% for each, and group 2 (n = 20) received local wound infiltration at end of surgery with 40 ml of bupivacaine 0.25%. A standardized postoperative analgesic regimen composed of intravenous paracetamol and a morphine patient-controlled analgesia (PCA). The use of intraoperative fentanyl and recovery room morphine boluses, PCA-administered morphine, pain scores as well as number of patients' experienced postoperative nausea and vomiting in the ward at 6 and 24 h were recorded. Group 1 patients received a significantly lower cumulative intraoperative fentanyl, significantly lesser boluses of morphine in postanesthesia care unit, as well, significantly lower cumulative 24 h postoperative morphine dosage than the group 2 patients. Pain visual analog scale scores were significantly lower at both 6 and 24 h postoperatively in TAP group when compared with the no-TAP group. There were no complications related to the TAP block procedures. No signs or symptoms of local anesthetic systemic toxicity were detected. The combination of bilateral US-guided RS and TAP blocks provides excellent perioperative analgesia for major upper abdominal surgery.

  17. Ultrasound-guided transversus abdominis plane block for postoperative analgesia in living liver donors: A prospective, randomized, double-blinded clinical trial.

    PubMed

    Kıtlık, Arzu; Erdogan, Mehmet Ali; Ozgul, Ulku; Aydogan, Mustafa Said; Ucar, Muharrem; Toprak, Huseyin Ilksen; Colak, Cemil; Durmus, Mahmut

    2017-02-01

    Transversus abdominis plane (TAP) block is a peripheral nerve block that reduces postoperative pain, nausea, vomiting and the need for postoperative opioids following various types of abdominal surgery. The primary aim of the present study was to evaluate the effects of TAP block on postoperative analgesia and opioid consumption in living liver donors in whom a right "J" abdominal incision was used. This prospective, double-blinded, randomized controlled study was conducted with 50 living liver donors, aged 18-65years, who were scheduled to undergo right hepatectomy. Patients who received ultrasonography-guided subcostal TAP block were allocated into Group 1, and patients who did not receive TAP block were allocated into Group 2. The TAP blocks were performed bilaterally at the conclusion of surgery using 1.5mg∗kg -1 bupivacaine diluted with saline to reach a total volume of 40mL. For each patient, morphine consumption, pain scores at rest and movement, sedation scores, nausea, vomiting and the need for antiemetic medication were assessed at 0, 2, 4, 6, 12 and 24h postoperatively by researchers who were blinded to the study groups. Morphine consumption was significantly lower in Group 1 than in Group 2 at the 2nd, 6th and 24th hours (P<0.05). The mean total morphine consumption values after 24h were 40mg and 65mg in Groups 1 and 2, respectively. The TAP block significantly reduced postoperative visual analog scale pain scores both at rest and during movement at 0, 2, 4, 6, and 24h postoperatively (P<0.05). The TAP block reduced 24-h postoperative morphine consumption and contributed to analgesia in living liver donors who underwent upper abdominal wall incisions. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Effects of preoperative ultrasound-guided transversus abdominis plane block on pain after laparoscopic surgery for colorectal cancer: a double-blind randomized controlled trial.

    PubMed

    Oh, Tak Kyu; Yim, Jiyeon; Kim, Jaehyun; Eom, Woosik; Lee, Soon Ae; Park, Sung Chan; Oh, Jae Hwan; Park, Ji Won; Park, Boram; Kim, Dae Hyun

    2017-01-01

    Although laparoscopic colorectal surgery decreases postoperative pain and facilitates a speedier recovery compared with laparotomy, postoperative pain at trocar insertion sites remains a clinical concern. The objective of this study was to assess the effects of a preoperative ultrasound-guided transversus abdominis plane (TAP) block on pain after laparoscopic surgery for colorectal cancer. In total, 58 patients scheduled to undergo laparoscopic surgery following a diagnosis of colorectal cancer were included in this study. The patients were randomized into TAP and control groups; the TAP group patients received a preoperative ultrasound-guided bilateral TAP block with 0.5 mL/kg of 0.25 % bupivacaine, while the control patients received the block with an equal amount of saline. Pain on coughing and at rest was assessed during postanesthetic recovery (PAR; 1 h after surgery) and on postoperative days (PODs) 1 (24 h), 2 (48 h), and 3 (72 h) by an investigator blinded to group allocations using the numeric rating scale (NRS). The primary outcome was pain on coughing on postoperative day (POD) 1. Fifty-five patients were included in the final analysis, including 28 in the TAP and 27 in the control groups. The pain intensity on coughing and at rest during PAR and on PODs 1, 2, and 3 showed no significant differences between groups. Furthermore, there was no significant difference in postoperative opioid consumption, sedation scores, nausea scores at the four time points, complication rates, and length of hospital stay between groups. In colorectal cancer patients undergoing laparoscopic colorectal surgery, a TAP block did not offer enough benefit for clinical efficacy in terms of postoperative pain or analgesic consumption.

  19. Postoperative Analgesic Efficacy of Bilateral Transversus Abdominis Plane Block in Patients Undergoing Midline Colorectal Surgeries Using Ropivacaine: A Randomized, Double-blind, Placebo-controlled Trial.

    PubMed

    Qazi, Nahida; Bhat, Wasim Mohammad; Iqbal, Malik Zaffar; Wani, Anisur Rehman; Gurcoo, Showkat A; Rasool, Sahir

    2017-01-01

    Ultrasound-guided transversus abdominis plane (TAP) block is done as a part of multimodal analgesia for pain relief after abdominal surgeries. This prospective randomized, double-blind, placebo-controlled trial was conducted to evaluate the postoperative analgesic efficacy of bilateral TAP block in patients undergoing midline colorectal surgeries using ropivacaine. Eighty patients scheduled for elective colorectal surgeries involving midline abdominal wall incision under general anesthesia were enrolled in this prospective randomized controlled trial. Group A received TAP block with 20 ml of 0.2% ropivacaine on either side of the abdominal wall, and Group B received 20 ml of normal saline. The time to request for rescue analgesia, total analgesic consumption in 24 h, and satisfaction with the anesthetic technique were assessed. The mean visual analog scale scores at rest and on coughing were higher in control group ( P > 0.05). Time (min) to request for the first rescue analgesia was prolonged in study group compared to control group ( P < 0.001). The total tramadol consumption in 24 h postoperatively was significantly high in control group ( P < 0.001). Nausea/vomiting was more common in control group ( P > 0.05). The level of satisfaction concerning postoperative pain control/anesthetic technique was higher in study group ( P < 0.001). TAP block produces effective and prolonged postoperative analgesia in patients undergoing midline colorectal surgery. It is a technically simple block to perform with a high margin of safety. It produces a considerable reduction in mean intravenous postoperative tramadol requirements, reduction in postoperative pain scores, and increased time to first request for further analgesia, both at rest and on movement.

  20. High-dose versus low-dose local anaesthetic for transversus abdominis plane block post-Caesarean delivery analgesia: a meta-analysis.

    PubMed

    Ng, S C; Habib, A S; Sodha, S; Carvalho, B; Sultan, P

    2018-02-01

    The optimal local-anaesthetic (LA) dose for transversus-abdominis-plane (TAP) block is unclear. In this meta-analysis, we aimed to determine whether TAP blocks for Caesarean delivery (CD) with low-dose (LD) LA demonstrated non-inferiority in terms of analgesic efficacy, compared with high-dose (HD) LA. A literature search was performed for randomised controlled trials examining the analgesic efficacy of TAP blocks vs control after CD. The different dosing used in these studies was classified as HD or LD (bupivacaine equivalents >50 or ≤50 mg per block side, respectively). The pooled results of each dose group vs control were indirectly compared using the Q test. The primary outcome was 24 h opioid consumption. Secondary outcomes included 6 and 24 h postoperative pain scores, time to first analgesia, 6 h opioid consumption, opioid-related side-effects, and maternal satisfaction. Fourteen studies consisting of 770 women (389 TAP and 381 control) were included. Compared with controls, the 24 h opioid consumption (milligram morphine equivalents) was lower in HD [mean difference (MD) 95% confidence interval (CI) -22.41 (-38.56, -6.26); P=0.007; I 2 =93%] and LD [MD 95% CI -16.29 (-29.74, -2.84); P=0.02; I 2 =98%] TAP groups. However, no differences were demonstrated between the HD and LD groups (P=0.57). There were also no differences between the HD and LD groups for the 6 h opioid consumption, time to first analgesia, 6 and 24 h pain scores, postoperative nausea and vomiting, pruritus, and maternal satisfaction. Low-dose TAP blocks for Caesarean delivery provide analgesia and opioid-sparing effects comparable with the high-dose blocks. This suggests that lower doses can be used to reduce local anaesthetic toxicity risk without compromising the analgesic efficacy. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  1. A Comparative Study of Analgesic Efficacy of Intrathecal Buprenorphine with Ultrasound-Guided Transversus Abdominis Plane Block for Postcesarean Delivery Analgesia.

    PubMed

    Marappa, Prakash; Chikkapillappa, Manjunath Abloodu; Chennappa, Nagaraj Mungasuvalli; Pujari, Vinayak Seenappa

    2017-01-01

    Women undergoing cesarean (CS) delivery present a unique set of challenges to the anesthetist in terms of postoperative pain management. This study was conducted to compare the analgesic efficacy of intrathecal buprenorphine (ITB) with ultrasound-guided transversus abdominis plane (TAP) block in post-CS delivery pain. A prospective randomized comparative study of sixty American Society of Anesthesiologists physical status I and II pregnant patients divided into two groups of thirty each as ITB group and TAP block group after satisfying the inclusion criteria. In the present study, demographic data were comparable between both groups. The time to first analgesic request was significantly longer in ITB group (389.67 ± 90.78 min) compared to TAP group (669.17 ± 140.65 min) and was statistically significant, P < 0.001. The mean paracetamol consumption in the first 24 h was higher in the TAP group (3.5 g) compared to the ITB group (1.13 g) and was statistically significant, P < 0.0001, and the mean tramadol consumed in first 24 h was higher in the TAP (46.66 mg) group as compared to the ITB group (16.66 mg) and was statistically significant, P < 0.001. The mean visual analog scale scores assessed at 4, 6, 12, and 24 h was higher in the TAP group and was statistically significant, P < 0.001. Our study showed that patients receiving ITB for post-CS pain management reported longer duration of analgesia, lower pain scores, and lower analgesic consumption during the first 24 h. The benefits of neuraxial opiates are significant and far outweigh the side effects.

  2. Evaluation of transversus abdominis plane block for renal transplant recipients - A meta-analysis and trial sequential analysis of published studies.

    PubMed

    Singh, Preet Mohinder; Borle, Anuradha; Makkar, Jeetinder Kaur; Trisha, Aanjan; Sinha, Aashish

    2018-01-01

    Patients undergoing renal transplant (RT) have altered drug/opioid pharmacokinetics. Transversus abdominis plane (TAP) block in renal transplant recipients has been recently evaluated for analgesic and opioid-sparing potential by many trials. The studies comparing TAP-block to conventional analgesic regimens for RT were searched. Comparisons were made for total opioids consumed (as morphine-equivalents) during the first postoperative 24-h (primary objective), intraoperative, and immediate-postoperative period. Pain scores and postoperative nausea-vomiting (PONV) were also evaluated. Trial sequential analysis (TSA) was used to quantify the strength of analysis. Ten-trials with 258 and 237 patients in control and TAP-block group, respectively, were included. TAP-block decreased the 24-h (reported in 9-trials) opioid consumption by 14.61 ± 4.34 mg (reduction by 42.7%, random-effects, P < 0.001, I 2 = 97.82%). Sample size of the present analysis (472) was well past the required "information-size" variable (396) as per the TSA for a power of 85%. Intraoperative opioid consumption also decreased by 2.06 ± 0.63 mg (reduction of 27.8%) (random effects, P < 0.001, I 2 = 98.84%). Pain scores with TAP-block were significantly lower in both early and delayed postoperative phase. Odds ratio for PONV without TAP block was 1.99 ± 1.05 (Fixed-effects, P = 0.04, I 2 = 0%). Publication bias was likely (Egger's test, X-intercept=7.89, P < 0.05). TAP-block significantly lowers the intraoperative and cumulative postoperative 24-h opioid consumption in RT recipients. Persistent and better pain control is achieved when TAP-Block is used. Benefits of TAP block extend beyond the analgesic actions alone as it also decreases the 24-h incidence of postoperative nausea vomiting as well. The technique of the block needs standardization for RT recipients.

  3. Cutaneous Sensory Block Area, Muscle-Relaxing Effect, and Block Duration of the Transversus Abdominis Plane Block: A Randomized, Blinded, and Placebo-Controlled Study in Healthy Volunteers.

    PubMed

    Støving, Kion; Rothe, Christian; Rosenstock, Charlotte V; Aasvang, Eske K; Lundstrøm, Lars H; Lange, Kai H W

    2015-01-01

    The transversus abdominis plane (TAP) block is a widely used nerve block. However, basic block characteristics are poorly described. The purpose of this study was to assess the cutaneous sensory block area, muscle-relaxing effect, and block duration. Sixteen healthy volunteers were randomized to receive an ultrasound-guided unilateral TAP block with 20 mL 7.5 mg/mL ropivacaine and placebo on the contralateral side. Measurements were performed at baseline and 90 minutes after performing the block. Cutaneous sensory block area was mapped and separated into a medial and lateral part by a vertical line through the anterior superior iliac spine. We measured muscle thickness of the 3 lateral abdominal muscle layers with ultrasound in the relaxed state and during maximal voluntary muscle contraction. The volunteers reported the duration of the sensory block and the abdominal muscle-relaxing effect. The lateral part of the cutaneous sensory block area was a median of 266 cm2 (interquartile range, 191-310 cm2) and the medial part 76 cm 2(interquartile range, 54-127 cm2). In all the volunteers, lateral wall muscle thickness decreased significantly by 9.2 mm (6.9-15.7 mm) during a maximal contraction. Sensory block and muscle-relaxing effect duration were 570 minutes (512-716 minutes) and 609 minutes (490-724 minutes), respectively. Cutaneous sensory block area of the TAP block is predominantly located lateral to a vertical line through the anterior superior iliac spine. The distribution is nondermatomal and does not cross the midline. The muscle-relaxing effect is significant and consistent. The block duration is approximately 10 hours with large variation.

  4. Postoperative Analgesic Efficacy of Bilateral Transversus Abdominis Plane Block in Patients Undergoing Midline Colorectal Surgeries Using Ropivacaine: A Randomized, Double-blind, Placebo-controlled Trial

    PubMed Central

    Qazi, Nahida; Bhat, Wasim Mohammad; Iqbal, Malik Zaffar; Wani, Anisur Rehman; Gurcoo, Showkat A.; Rasool, Sahir

    2017-01-01

    Background: Ultrasound-guided transversus abdominis plane (TAP) block is done as a part of multimodal analgesia for pain relief after abdominal surgeries. This prospective randomized, double-blind, placebo-controlled trial was conducted to evaluate the postoperative analgesic efficacy of bilateral TAP block in patients undergoing midline colorectal surgeries using ropivacaine. Materials and Methods: Eighty patients scheduled for elective colorectal surgeries involving midline abdominal wall incision under general anesthesia were enrolled in this prospective randomized controlled trial. Group A received TAP block with 20 ml of 0.2% ropivacaine on either side of the abdominal wall, and Group B received 20 ml of normal saline. The time to request for rescue analgesia, total analgesic consumption in 24 h, and satisfaction with the anesthetic technique were assessed. Results: The mean visual analog scale scores at rest and on coughing were higher in control group (P > 0.05). Time (min) to request for the first rescue analgesia was prolonged in study group compared to control group (P < 0.001). The total tramadol consumption in 24 h postoperatively was significantly high in control group (P < 0.001). Nausea/vomiting was more common in control group (P > 0.05). The level of satisfaction concerning postoperative pain control/anesthetic technique was higher in study group (P < 0.001). Conclusion: TAP block produces effective and prolonged postoperative analgesia in patients undergoing midline colorectal surgery. It is a technically simple block to perform with a high margin of safety. It produces a considerable reduction in mean intravenous postoperative tramadol requirements, reduction in postoperative pain scores, and increased time to first request for further analgesia, both at rest and on movement. PMID:28928585

  5. Analgesic efficacy of ultrasound guided transversus abdominis plane block versus local anesthetic infiltration in adult patients undergoing single incision laparoscopic cholecystectomy: A randomized controlled trial

    PubMed Central

    Bava, Ejas P.; Ramachandran, Rashmi; Rewari, Vimi; Chandralekha; Bansal, Virinder Kumar; Trikha, Anjan

    2016-01-01

    Background: Transversus abdominis plane (TAP) block has been used to provide intra- and post-operative analgesia with single incision laparoscopic (SIL) bariatric and gynecological surgery with mixed results. Its efficacy in providing analgesia for SIL cholecystectomy (SILC) via the same approach remains unexplored. Aims: The primary objective of our study was to compare the efficacy of bilateral TAP block with local anesthetic infiltration for perioperative analgesia in patients undergoing SILC. Settings and Design: This was a prospective, randomized, controlled, double-blinded trial performed in a tertiary care hospital. Materials and Methods: Forty-two patients undergoing SILC were randomized to receive either ultrasound-guided (USG) bilateral mid-axillary TAP blocks with 0.375% ropivacaine or local anesthetic infiltration of the port site. The primary outcome measure was the requirement of morphine in the first 24 h postoperatively. Statistical Analysis: The data were analyzed using t-test, Mann–Whitney test or Chi-square test. Results: The 24 h morphine requirement (mean ± standard deviation) was 34.57 ± 14.64 mg in TAP group and 32.76 ± 14.34 mg in local infiltration group (P = 0.688). The number of patients requiring intraoperative supplemental fentanyl in TAP group was 8 and in local infiltration group was 16 (P = 0.028). The visual analog scale scores at rest and on coughing were significantly higher in the local infiltration group in the immediate postoperative period (P = 0.034 and P = 0.007, respectively). Conclusion: USG bilateral TAP blocks were not effective in decreasing 24 h morphine requirement as compared to local anesthetic infiltration in patients undergoing SILC although it provided some analgesic benefit intraoperatively and in the initial 4 h postoperatively. Hence, the benefits of TAP blocks are not worth the effort and time spent for administering them for this surgery. PMID:27746552

  6. Ultrasound-guided transversus abdominis plane block in patients undergoing open inguinal hernia repair: 0.125% bupivacaine provides similar analgesic effect compared to 0.25% bupivacaine.

    PubMed

    Erdoğan Arı, Dilek; Yıldırım Ar, Arzu; Karadoğan, Firdevs; Özcabı, Yetkin; Koçoğlu, Ayşegül; Kılıç, Fatih; Akgün, Fatma Nur

    2016-02-01

    To evaluate the effectiveness of 0.125% bupivacaine compared to 0.25% bupivacaine for ultrasound-guided transversus abdominis plane (TAP) block in patients undergoing open inguinal hernia repair. Randomized, double-blind study. Educational and research hospital. Forty adult patients of American Society of Anesthesiologists physical status I-III undergoing elective primary unilateral open inguinal hernia repair under spinal anesthesia. Patients in group I received 20 mL of 0.25% bupivacaine, whereas patients in group II received 20 mL of 0.125% bupivacaine for TAP block at the end of the surgery. Pain intensity was assessed at rest and during coughing using 10-cm visual analog scale score at 5, 15, 30, and 45 minutes and 1, 2, 4, 6, 12, and 24 hours after TAP block. Morphine consumption and time to first morphine requirement were recorded. Visual analog scale scores at rest and during coughing were not significantly different between groups at all time points measured. Twenty-four hours of morphine consumption (7.72±7.33 mg in group I and 6.06±5.20 mg in group II; P=.437) and time to first morphine requirement (182.35±125.16 minutes in group I and 143.21±87.28 minutes in group II; P=.332) were not different between groups. 0.125% Bupivacaine provides similar analgesic effect compared to 0.25% bupivacaine for ultrasound-guided TAP block in patients undergoing open inguinal hernia repair. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Effect of local wound infiltration and transversus abdominis plane block on morphine use after laparoscopic colectomy: a nonrandomized, single-blind prospective study.

    PubMed

    Park, Jun-Seok; Choi, Gyu-Seog; Kwak, Kyung-Hwa; Jung, Hoon; Jeon, Younghoon; Park, Sungsik; Yeo, Jinseok

    2015-05-01

    Recently, nonopioid-based treatment modalities have been used to improve analgesia and decrease opioid-related side effects after surgery. Transversus abdominis plane (TAP) block and local infiltration of the surgical wound are commonly used multimodal analgesia techniques after abdominal surgery; however, few studies have compared the effectiveness of a TAP block with that of local infiltration of surgical wounds in patients who have undergone laparoscopic colorectal surgery. Sixty patients undergoing laparoscopic colorectal surgery participated in this prospective comparative study. All patients were allocated to 1 of 2 groups as follows: the TAP group or the infiltration group. Patients in the TAP group received bilateral TAP blocks at the end of the surgery. Patients in the infiltration group received local infiltration of anesthetics in the surgical wounds after closure of the peritoneum. All patients received postoperative analgesia with morphine as a patient-controlled analgesia. Opioid consumption and pain scores were recorded at 2, 6, 24, and 48 h after the operation. The characteristics of patients in the TAP group (n = 30) and local infiltration group (n = 29) were comparable. Pain scores while coughing and at rest were not different between the two groups. Postoperative morphine use was significantly reduced in the TAP group compared with that in the local infiltration group at 2-6 h (2.9 ± 1.9 mg versus 4.5 ± 3.2 mg, P = 0.02), 6-24 h (5.5 ± 3.3 mg versus 10.2 ± 8.4 mg, P = 0.00), the first 24 h (16.6 ± 6.6 mg versus 24.0 ± 9.7 mg), and 48 h (23.6 ± 8.2 mg versus 31.8 ± 12.5 mg, P = 0.00). No differences in rescue analgesic use or side effects were noted between the groups. Compared with local anesthetic infiltration, bilateral TAP blocks decreased the cumulative morphine use at 24 h and 48 h postoperatively in patients who had undergone laparoscopic colorectal surgery. Copyright © 2015 Elsevier Inc

  8. Transversus abdominis plane block using a short-acting local anesthetic for postoperative pain after laparoscopic colorectal surgery: a systematic review and meta-analysis.

    PubMed

    Oh, Tak Kyu; Lee, Se-Jun; Do, Sang-Hwan; Song, In-Ae

    2018-02-01

    Transversus abdominis plane (TAP) block using a short-acting local anesthetic as part of multimodal analgesia is efficient in various abdominal surgeries, including laparoscopic surgery. However, information regarding its use in laparoscopic colorectal surgery is still limited and sometimes controversial. Therefore, we conducted a systematic review and meta-analysis to determine whether TAP block using a short-acting anesthetic has a positive postoperative analgesic outcome in patients who have undergone laparoscopic colorectal surgery. We searched for studies comparing the postoperative pain outcome after laparoscopic colorectal surgery between patients who received TAP block and a control group (placebo or no treatment). Outcome measures were early pain at rest (numeric rating scale [NRS] score at 0-2 h postoperatively), late pain at movement (NRS score at 24 h postoperatively), late pain at rest (NRS score at 24 h postoperatively), and postoperative opioid consumption (up to 24 h postoperatively). We used a random-effects model for the meta-analysis and Egger's regression test to detect publication bias. We included six studies involving 452 patients (224 in the TAP block group, 228 in the control group). Early and late pain scores at movement were significantly different between the TAP block and control groups (standardized mean difference: - 0.695, P < 0.0001 for early pain and - 0.242, P = 0.029 for late pain). There was no significant difference between the TAP block and control groups in early pain at rest (P = 0.475), late pain at rest (P = 0.826), and postoperative opioid consumption (P = 0.257). The TAP block using a short-acting anesthetic had a significant effect on the postoperative pain outcome in the early (0-2 h) and late (24 h) period at movement. However, it did not have a significant effect on the postoperative pain outcome in the early (0-2 h) and late (24 h) periods at rest after laparoscopic surgery.

  9. Role of ultrasound guided transversus abdominis plane block as a component of multimodal analgesic regimen for lower segment caesarean section: a randomized double blind clinical study.

    PubMed

    Jadon, Ashok; Jain, Priyanka; Chakraborty, Swastika; Motaka, Mayur; Parida, Sudhansu Sekhar; Sinha, Neelam; Agrawal, Amit; Pati, Asit Kumar

    2018-05-14

    While opioids are the mainstay for post-operative analgesia after lower segment caesarean section, they are associated with various untoward effects. Ultrasound guided transversus abdominis plane (TAP) block has been postulated to provide effective analgesia for caesarean section. We evaluated the analgesic efficacy of this block for post caesarean analgesia in a randomised controlled trial. One hundred thirty-nine mothers undergoing caesarean delivery were randomised to receive TAP block with either 20 ml 0.375% ropivacaine or 20 ml saline after obtaining informed consent. All the subjects received a standard spinal anaesthetic and diclofenac was administered for post-operative pain. Breakthrough pain was treated with tramadol. Post-operatively, all the subjects were assessed at 0, 2, 4, 6, 8, 10, 12, 18 & 24 h. The primary outcome was the time to first analgesic request. The secondary measures of outcome were pain, nausea, sedation, number of doses of tramadol administered and satisfaction with the pain management. The median (interquartile range) time to first analgesic request was prolonged in the TAP group compared to the control group (p < 0.0001); 11 h (8,12) and 4 h (2.5,6) respectively. The median (interquartile range) number of doses of tramadol consumed in the TAP group was 0 (0,1) compared to 2 (1,2) in the control group (p < 0.0001). At all points in the study, pain scores both at rest and on movement were lower in the study group (p < 0.0001). Maternal satisfaction with pain relief was also higher in the study group (p 0.0002). One subject in the TAP group had convulsions following injection of local anaesthetic solution. She was managed conservatively with supportive treatment following which she recovered. TAP block reduces pain, prolongs the duration of analgesia and decreases supplemental opioid consumption when used for multimodal analgesia for pain relief after caesarean section. However, the risk of local anaesthetic systemic

  10. Transversus Abdominis Plane Block versus Ilioinguinal/Iliohypogastric Nerve Block with Wound Infiltration for Postoperative Analgesia in Inguinal Hernia Surgery: A Randomized Clinical Trial.

    PubMed

    Sujatha, Chinthavali; Zachariah, Mamie; Ranjan, R V; George, Sagiev Koshy; Ramachandran, T R; Pillai, Anil Radhakrishna

    2017-01-01

    Various analgesic modalities have been used for postoperative analgesia in patients undergoing inguinal hernia surgery. In this randomized clinical trial, we have compared the analgesic efficacy of transversus abdominis plane (TAP) block with that of ilioinguinal/iliohypogastric (IIIH) nerve block with wound infiltration in patients undergoing unilateral open inguinal hernia repair. The primary objective of this study was to compare the efficacy of postoperative analgesia of ultrasound-guided TAP block and IIIH block with wound infiltration (WI) in patients undergoing open inguinal hernia surgery. This was a randomized clinical trial performed in a tertiary care hospital. Sixty patients scheduled for hernia repair were randomized into two groups, Group T and Group I. Postoperatively, under ultrasound guidance, Group T received 20 ml of 0.25% ropivacaine - TAP block and Group I received 10 ml of 0.25% ropivacaine - IIIH block + WI with 10 ml of 0.25% ropivacaine. The primary outcome measure was the time to rescue analgesia in the first 24 h postoperatively. Fentanyl along with diclofenac was given as first rescue analgesic when the patient complained of pain. Statistical comparisons were performed using Student's t -test and Chi-square test. Mean time to rescue analgesia was 5.900 ± 1.881 h and 3.766 ± 1.754 h ( P < 0.001) and the mean pain scores were 5.73 ± 0.784 and 6.03 ± 0.850 for Group TAP and IIIH + WI, respectively. Hemodynamics were stable in both the groups. One-third of the patients received one dose of paracetamol in addition to the rescue analgesic in the first 24 h. There were no complications attributed to the block. As a multimodal analgesic regimen, definitely both TAP block and IIIH block with wound infiltration have a supporting role in providing analgesia in the postoperative period for adult inguinal hernia repair. In this study, ultrasound-guided TAP block provided longer pain control postoperatively than IIIH block with WI after inguinal

  11. Dexmedetomidine decreases the required amount of bupivacaine for ultrasound-guided transversus abdominis plane block in pediatrics patients: a randomized study.

    PubMed

    Raof, Rehab Abdel; El Metainy, Shahira Ahmed; Alia, Doaa Abou; Wahab, Moataza Abdel

    2017-02-01

    The effect of dexmedetomidine on the potency of bupivacaine for transversus abdominis plane (TAP) block in pediatric patients has not been investigated. The primary objective of this study was to assess the effectiveness of dexmedetomidine to decrease the concentration of bupivacaine needed for analgesia for ultrasound-guided TAP block in a pediatric patient undergoing hernia repair or hydrocelectomy. This is a randomized, double-blind, up-down, dose-finding study. Operating room. Sixty American Society of Anesthesiologists I and II patients aged 1-4 years scheduled for elective unilateral herniorrhaphy or hydrocelectomy. Patients were randomly assigned to 1 of the 2 groups: group B (0.125% bupivacaine, 1mL/kg) TAP block or group BD (0.125% bupivacaine plus 2μg/kg dexmedetomidine, 1mL/kg) TAP block. The response of each child was observed for 60 seconds after skin incision and evaluated as 'unsuccessful' when skin incision caused a change in hemodynamic parameters (heart rate and mean blood pressure) 20% more than the preincision values. If the response was determined to be unsuccessful, the concentration of bupivacaine administrated to the next patient was increased by 0.02%. If it was successful, the concentration of bupivacaine administrated to the next patient was decreased by 0.02%. The minimum local anesthetic concentration of bupivacaine was 0.0839% (0.0137) in the B group and 0.0550% (0.0169) in the BD group. The difference was statistically significant (t=7.165, P=.0001). The total postoperative analgesic dosage of morphine was significantly higher in the B group (0.17±0.04 mg/kg) than the BD group (0.11±0.02 mg/kg, P=.001). The addition of 2μg/kg of dexmedetomidine reduced the minimum local anesthetic concentration of bupivacaine used for a TAP block and improved postoperative analgesia in children undergoing surgery for inguinal hernia repair or hydrocelectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Adding a transversus abdominis plane block to parenteral opioid for postoperative analgesia following trans-abdominal hysterectomy in a low resource setting: a prospective, randomised, double blind, controlled study.

    PubMed

    Moyo, Nomaqhawe; Madzimbamuto, Farai D; Shumbairerwa, Samson

    2016-01-28

    The current gold standard treatment for acute postoperative pain after major abdominal surgery is multimodal analgesia using patient controlled analgesia delivery systems. Patient controlled analgesia systems are expensive and their routine use in very low income countries is not practical. The use of ultrasound in anaesthesia has made some regional anaesthesia blocks technically easy and safe to perform. This study aimed to determine whether adding an ultrasound guided transversus abdominis plane block as an adjunct to the current parenteral opioid based regimen would result in superior pain relief after a trans abdominal hysterectomy compared to using parenteral opioids alone. Thirty-two elective patients having trans abdominal hysterectomy were recruited into a prospective randomised double-blind, controlled study comparing a bilateral transversus abdominis plane block using 21 ml of 0.25% bupivacaine and 4.0 mg dexamethasone with a sham block containing 21 ml 0.9% saline. Sixteen patients were allocated to each group. Anaesthesia and postoperative analgesia was left to the attending anaesthetist's discretion. Primary outcome was visual analogue scale for pain at 2 h and 4 h. Secondary outcomes were time to first request for analgesia, visual analogue scale for comfort and bother. The data were analysed using the Statistical Package for Social Sciences (SPSS version 16). There was no statistically significant difference in the demographics of the two groups regarding weight, height, physical status and type of surgical incision. There was a statistically significant difference in visual analogue scale for pain at 4 h during movement with lower pain scales in the test group (p = 0.034). Women in the control group had an average pain free period of 56.8 min (median 56.5 min) before requesting a rescue analgesic compared to 116.5 min (median 103 min) in the study group. The between group difference in the average total analgesia duration was statistically

  13. No benefit of ultrasound-guided transversus abdominis plane blocks over wound infiltration with local anaesthetic in elective laparoscopic colonic surgery: results of a double-blind randomized controlled trial.

    PubMed

    Rashid, A; Gorissen, K J; Ris, F; Gosselink, M P; Shorthouse, J R; Smith, A D; Pandit, J J; Lindsey, I; Crabtree, N A

    2017-07-01

    Advances in laparoscopic techniques combined with enhanced recovery pathways have led to faster recuperation and discharge after colorectal surgery. Peripheral nerve blockade using transversus abdominis plane (TAP) blocks reduce opioid requirements and provide better analgesia for laparoscopic colectomies than do inactive controls. This double-blind randomized study was performed to compare TAP blocks using bupivacaine with standardized wound infiltration with local anaesthetic (LA). Seventy-one patients were randomized to receive either TAP block or wound infiltration. The TAP blocks were performed by experienced anaesthetists who used ultrasound guidance to deliver 40 ml of 0.25% bupivacaine post-induction into the transverse abdominis plane. In the control group, 40 ml of 0.25% bupivacaine was injected around the trocar and the extraction site by the surgeon. Both groups received patient-controlled analgesia (PCA) with intravenous morphine. Patients and nursing staff assessed pain scores 6, 12, 24 and 48 h after surgery. The primary outcome was overall morphine use in the first 48 h. Of the 71 patients, 20 underwent a right hemicolectomy and 51 a high anterior resection. The modified intention-to-treat analysis showed no significant differences in overall morphine use [47.3 (36.2-58.5) mg vs 46.7 (36.2-57.3) mg; mean (95% CI), P = 0.8663] in the first 48 h. Pain scores were similar at 6, 12, 24 and 48 h. No differences were found regarding time to mobilization, resumption of diet and length of hospital stay. In elective laparoscopic colectomies, standardized wound infiltration with LA has the same analgesic effect as TAP blocks post-induction using bupivacaine at 48 h. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  14. Case Report of Serratus Plane Catheter for Pain Management in a Patient With Multiple Rib Fractures and an Inferior Scapular Fracture.

    PubMed

    Fu, Peter; Weyker, Paul D; Webb, Christopher A J

    2017-03-15

    We placed a superficial serratus anterior plane catheter in an elderly woman with dementia and elevated clotting times who presented with multiple rib fractures after a mechanical fall. She was not a surgical candidate, and treatment consisted of conservative management with physical therapy and pain control. She was not a candidate for a patient-controlled analgesia regimen because of her dementia. Given her elevated international normalized ratio, thoracic epidural and paravertebral analgesia was also contraindicated. We placed an ultrasound-guided serratus anterior plane catheter, allowing titratable continuous infusion in a trauma patient, resulting in excellent analgesia without adverse effects.

  15. Relative Efficacy of Ultrasound-guided Ilioinguinal-iliohypogastric Nerve Block versus Transverse Abdominis Plane Block for Postoperative Analgesia following Lower Segment Cesarean Section: A Prospective, Randomized Observer-blinded Trial.

    PubMed

    Kiran, L Vamsee; Sivashanmugam, T; Kumar, V R Hemanth; Krishnaveni, N; Parthasarathy, S

    2017-01-01

    Quality of postoperative analgesia after cesarean section makes difference to mother in child bonding, early ambulation, and discharge. Ilioinguinal iliohypogastric (ILIH) and transverse abdominis plane (TAP) block had been tried to reduce the opioid analgesics, but the relative efficacy is unknown. Hence, this study was designed to compare the efficacy of these two regional analgesic techniques in sparing postoperative rescue analgesic requirement following lower segment cesarean section (LSCS). Sixty patients who underwent LSCS were randomly allocated into two groups to receive either US-guided TAP block or ILIH nerve block using sealed envelope technique at the end of the surgery. In the postoperative ward, whenever patient complained of pain, pain nurse in-charge administered the rescue analgesics as per the study protocol. A blinded observer visited the patient at 0, 2, 4, 6, 8, 10, 12, and 24 h postoperative intervals and recorded the quality of pain relief and the amount of rescue analgesic consumed. All patients in both the study groups required one dose of rescue analgesics in the form of injection diclofenac sodium 50 mg intravenously but subsequently 57% of patients did not require any further analgesics till 24 h in the TAP block group whereas in ILIH group, only 13% did not require further analgesics ( P = 0.00), correspondingly the cumulative tramadol dose was significantly higher at all the time interval in the ILIH group when compared to the TAP group. Quality of postoperative analgesia provided by TAP block was superior to ILIH block following LSCS.

  16. Bilateral Subpectoral Interfascial Plane Catheters for Analgesia for Sternal Fractures: A Case Report.

    PubMed

    Raza, Irfan; Narayanan, Madankumar; Venkataraju, Arun; Ciocarlan, Alexandra

    2016-01-01

    Sternal fractures occur after deceleration injuries such as falls and road traffic accidents. Recovery from isolated fractures is excellent, but mortality increases dramatically with concurrent chest injuries such as rib fractures and soft tissue injuries. Short-term complications include chest pain, which prevents patients from taking deep breaths and coughing, thereby predisposing them to chest infections. We present a case of a 73-year-old woman with sternal fracture in whom enteral analgesia was inadequate and who was intolerant to intravenous opiates. The patient was successfully treated with a continuous infusion of local anesthetic into the subpectoral interfascial plane. We also discuss the use and potential benefits of the subpectoral interfascial plane block in the treatment of pain from sternal fractures.

  17. Effect of transversus abdominis plane block in combination with general anesthesia on perioperative opioid consumption, hemodynamics, and recovery in living liver donors: The prospective, double-blinded, randomized study.

    PubMed

    Erdogan, Mehmet A; Ozgul, Ulku; Uçar, Muharrem; Yalin, Mehmet R; Colak, Yusuf Z; Çolak, Cemil; Toprak, Huseyin I

    2017-04-01

    Transversus abdominis plane (TAP) block provides effective postoperative analgesia after abdominal surgeries. It can be also a useful strategy to reduce perioperative opioid consumption, support intraoperative hemodynamic stability, and promote early recovery from anesthesia. The aim of this prospective randomized double-blind study was to assess the effect of subcostal TAP blocks on perioperative opioid consumption, hemodynamic, and recovery time in living liver donors. The prospective, double-blinded, randomized controlled study was conducted with 49 living liver donors, aged 18-65 years, who were scheduled to undergo right hepatectomy. Patients who received subcostal TAP block in combination with general anesthesia were allocated into Group 1, and patients who received general anesthesia alone were allocated into Group 2. The TAP blocks were performed bilaterally by obtaining an image with real-time ultrasound guidance using 0.5% bupivacaine diluted with saline to reach a total volume of 40 mL. The primary outcome measure in our study was perioperative remifentanil consumption. Secondary outcomes were mean blood pressure (MBP), heart rate (HR), mean desflurane requirement, anesthesia recovery time, frequency of emergency vasopressor use, total morphine use, and length of hospital stay. Total remifentanil consumption and the anesthesia recovery time were significantly lower in Group 1 compared with Group 2. Postoperative total morphine use and length of hospital stay were also reduced. Changes in the MAP and HR were similar in the both groups. There were no significant differences in HR and MBP between groups at any time. Combining subcostal TAP blocks with general anesthesia significantly reduced perioperative and postoperative opioid consumption, provided shorter anesthesia recovery time, and length of hospital stay in living liver donors. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Effect of addition of dexamethasone to ropivacaine on post-operative analgesia in ultrasonography-guided transversus abdominis plane block for inguinal hernia repair: A prospective, double-blind, randomised controlled trial.

    PubMed

    Sharma, Uma Datt; Prateek; Tak, Himani

    2018-05-01

    Ultrasonography (USG)-guided transversus abdominis plane (TAP) block is an abdominal field block with high efficacy. This study was undertaken with the aim of determining the effect of the addition of dexamethasone to 0.5% ropivacaine on post-operative analgesia in USG-guided TAP block for inguinal hernia repair. A double-blind randomised control study was conducted on sixty patients posted for inguinal hernia repair with the American Society of Anesthesiologists physical Status I or II, who were allocated two groups of 30 each. Patients in Group RS received 0.5% ropivacaine (20 ml) and normal saline (2 ml) whereas patients in Group RD received 0.5% ropivacaine (20 ml) and dexamethasone (2 ml, i.e., 8 mg), in USG-guided TAP Block on the same side, after repair of inguinal hernia under spinal anaesthesia. Visual analogue scale (VAS) scores, time for request of first analgesia and total tramadol consumption in first 24 h were compared. Unpaired Student's t -test and Mann-Whitney U-test were performed using SPSS 23 Software. Patients in Group RD had significantly lower VAS scores as compared to Group RS from 4 th to 12 th h, postoperatively. Duration of analgesia was significantly more in Group RD (547.50 [530,530] min) when compared with Group RS (387.50 [370,400] min) ( P < 0.001). The demand for intravenous tramadol was significantly low in Group RD (223.33 ± 56.83 mg) as compared to Group RS (293.33 ± 25.71 mg) ( P < 0.001). Addition of dexamethasone to ropivacaine in USG-guided TAP block significantly reduces post-operative pain and prolongs the duration of post-operative analgesia, thereby reducing analgesic consumption.

  19. A comparative study to evaluate ultrasound-guided transversus abdominis plane block versus ilioinguinal iliohypogastric nerve block for post-operative analgesia in adult patients undergoing inguinal hernia repair.

    PubMed

    Kamal, Kirti; Jain, Parul; Bansal, Teena; Ahlawat, Geeta

    2018-04-01

    Both transversus abdominis plane (TAP) block and combined ilioinguinal-iliohypogastric (IIN/IHN) blocks are used routinely under ultrasound (USG) guidance for postoperative pain relief in patients undergoing inguinal hernia surgery. This study compares USG guided TAP Vs IIN/IHN block for post-operative analgesic efficacy in adults undergoing inguinal hernia surgery. Sixty adults aged 18 to 60 with American Society of Anesthesiologsts' grade I or II were included. After general anaesthesia, patients in Group I received USG guided unilateral TAP block using 0.75% ropivacaine 3 mg/kg (maximum 25 mL) and those in Group II received IIN/IHN block using 10 mL 0.75% ropivacaine. Postoperative rescue analgesia was with tramadol (intravenous) IV ± diclofenac IV in the first 4 h followed by oral diclofenac subsequently. Total analgesic consumption in the first 24 h was the primary objective, intraoperative haemodynamics, number of attempts and time required for performing the block as well as the postoperative pain scores were also evaluated. Time to first analgesic request was 319.8 ± 115.2 min in Group I and 408 ± 116.4 min in Group II ( P = 0.005). Seven patients (23.33%) in Group I and two (6.67%) in Group II required tramadol in first four hours. No patient in either groups received diclofenac IV. The average dose of tablet diclofenac was 200 ± 35.96 mg in Group I and 172.5 ± 34.96 mg in Group II ( P = 0. 004). USG guided IIN/IHN block reduces the postoperative analgesic requirement compared to USG guided TAP block.

  20. Comparison of efficacy of transversus abdominis plane block and iliohypogastric/ilioinguinal nerve block for postoperative pain management in patients undergoing inguinal herniorrhaphy with spinal anesthesia: a prospective randomized controlled open-label study.

    PubMed

    Okur, Onur; Tekgul, Zeki Tuncel; Erkan, Nazif

    2017-10-01

    The purpose of this study was to compare the effects of lateral abdominal transversus abdominis plane block (TAP block) and iliohypogastric/ilioinguinal nerve block (IHINB) under ultrasound guidance for postoperative pain management of inguinal hernia repair. Secondary purposes were to compare the complication rates of the two techniques and to examine the effects of TAP block and IHINB on chronic postoperative pain. This was a prospective randomized controlled open-label study. After approval of the Research Ethics Board, a total of 90 patients were allocated to three groups of 30 by simple randomized sampling as determined with a priori power analysis. Peripheral nerve blocks (TAP block or IHINB) were administered to patients following subarachnoid block according to their allocated group. Patient pain scores, additional analgesic requirements and complication rates were recorded periodically and compared. Pain scores were significantly lower in the study groups (p < 0.001, p < 0.001, p < 0.001, p = 0.002, p < 0.001, p < 0.001 for 1, 2, 4, 6, 24, and 48 h and at 1 and 6 months, respectively). First pain declaration times were significantly longer in the study groups (TAP block group [GT] 266.6 ± 119.7 min; IHINB group [GI] 247.2 ± 128.7 min; and control group [GC] 79.1 ± 66.2 min; p < 0.001). At 24 h, the numeric rating scale scores of GT were significantly lower than GI (p = 0.048). Additional analgesic requirements of GT and GI patients were found to be significantly lower than GC patients (p = 0.001, p < 0.001, p = 0.006, p = 0.002, p = 0.001, p < 0.001 for 1, 2, 4, 6, 24, and 48 h, respectively). We conclude that administration of TAP block or IHINB for patients undergoing inguinal herniorrhaphy reduces the intensity of both acute and chronic postoperative pain and additional analgesic requirements.

  1. Urinary catheters

    MedlinePlus

    ... drainage bag. The condom catheter must be changed every day. INTERMITTENT CATHETERS You would use an intermittent catheter ... and the catheter itself with soap and water every day. Also clean the area after every bowel movement ...

  2. Hydrophilic Catheters

    PubMed Central

    2006-01-01

    Executive Summary Objective To review the evidence on the effectiveness of hydrophilic catheters for patients requiring intermittent catheterization. Clinical Need There are various reasons why a person would require catheterization, including surgery, urinary retention due to enlargement of the prostate, spinal cord injuries, or other physical disabilities. Urethral catheters are the most prevalent cause of nosocomial urinary tract infections, that is, those that start or occur in a hospital. A urinary tract infection (UTI) occurs when bacteria adheres to the opening of the urethra. Most infections arise from Escherichia coli, from the colon. The bacteria spread into the bladder, resulting in the development of an infection. The prevalence of UTIs varies with age and sex. There is a tenfold increase in incidence for females compared with males in childhood and throughout adult life until around 55 years, when the incidence of UTIs in men and women is equal, mostly as a consequence of prostatic problems in men. Investigators have reported that urethritis (inflammation of the urethra) is found in 2% to 19% of patients practising intermittent catheterization. The Technology Hydrophilic catheters have a polymer coating that binds o the surface of the catheter. When the polymer coating is submersed in water, it absorbs and binds the water to the catheter. The catheter surface becomes smooth and very slippery. This slippery surface remains intact upon insertion into the urethra and maintains lubrication through the length of the urethra. The hydrophilic coating is designed to reduce the friction, as the catheter is inserted with the intention of reducing the risk of urethral damage. It has been suggested that because the hydrophilic catheters do not require manual lubrication they are more sterile and thus less likely to cause infection. Most hydrophilic catheters are prepackaged in sterile water, or there is a pouch of sterile water that is broken and released into the

  3. Rectus sheath catheters for continuous analgesia after upper abdominal surgery.

    PubMed

    Cornish, Philip; Deacon, Alf

    2007-01-01

    The segmental nerves T6-T11 pass through and innervate the rectus abdominis muscle and overlying skin. The arcuate lines compartmentalize the rectus, but they are deficient posteriorly and hence a catheter tunnelled into the posterior sheath can be used to achieve an effective continuous analgesic block. Volume is important to fill the compartment. It is a simple surgical procedure that has several advantages and appears a viable alternative to epidural analgesia.

  4. Rectus abdominis atrophy after ventral abdominal incisions: midline versus chevron.

    PubMed

    Vigneswaran, Y; Poli, E; Talamonti, M S; Haggerty, S P; Linn, J G; Ujiki, M B

    2017-08-01

    Although many outcomes have been compared between a midline and chevron incision, this is the first study to examine rectus abdominis atrophy after these two types of incisions. Patients undergoing open pancreaticobiliary surgery between 2007 and 2011 at our single institution were included in this study. Rectus abdominis muscle thickness was measured on both preoperative and follow-up computed tomography (CT) scans to calculate percent atrophy of the muscle after surgery. At average follow-up of 24.5 and 19.0 months, respectively, rectus abdominis atrophy was 18.9% greater in the chevron (n = 30) than in the midline (n = 180) group (21.8 vs. 2.9%, p < 0.0001). Half the patients with a chevron incision had >20% atrophy at follow-up compared with 10% with a midline incision [odds ratio (OR) 9.0, p < 0.0001]. No significant difference was observed in incisional hernia rates or wound infections between groups. In this study, chevron incisions resulted in seven times more atrophy of the rectus abdominis compared with midline incisions. The long-term effects of transecting the rectus abdominis and disrupting its innervation creates challenging abdominal wall pathology. Atrophy of the abdominal wall can not be readily fixed with an operation, and this significant side effect of a transverse incision should be factored into the surgeon's decision-making process when choosing a transverse over a midline incision.

  5. Hemodialysis Tunneled Catheter Noninfectious Complications

    PubMed Central

    Miller, Lisa M.; MacRae, Jennifer M.; Kiaii, Mercedeh; Clark, Edward; Dipchand, Christine; Kappel, Joanne; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; Pike, Pamela; Hiremath, Swapnil

    2016-01-01

    Noninfectious hemodialysis catheter complications include catheter dysfunction, catheter-related thrombus, and central vein stenosis. The definitions, causes, and treatment strategies for catheter dysfunction are reviewed below. Catheter-related thrombus is a less common but serious complication of catheters, requiring catheter removal and systemic anticoagulation. In addition, the risk factors, clinical manifestation, and treatment options for central vein stenosis are outlined. PMID:28270922

  6. Catheter tracking using continuous radial MRI.

    PubMed

    Rasche, V; Holz, D; Köhler, J; Proksa, R; Röschmann, P

    1997-06-01

    The guidance of minimally invasive procedures may become a very important future application of MRI. The guidance of interventions requires images of the anatomy as well as the information of the position of invasive devices used. This paper introduces continuous radial MRI for the simultaneous acquisition of the anatomic MR image and the position of one or more small RF-coils (mu-coils), which can be mounted on invasive devices such as catheters or biopsy needles. This approach allows the in-plane tracking of an invasive device without any prolongation of the overall acquisition time. The extension to three-dimensional position tracking is described. Phantom studies are presented demonstrating the capability of this technique for real-time automatic adjustment of the slice position to the current catheter position with a temporal resolution of 100 ms. Simultaneously the in-plane catheter position is depicted in the actually acquired MR image during continuous scanning.

  7. Indwelling catheter care

    MedlinePlus

    ... it overnight. You will be shown how to disconnect the bags from the Foley catheter in order ... bags through a separate valve without needing to disconnect the bag from the Foley catheter. Making Sure ...

  8. The influence of simulated transversus abdominis muscle force on sacroiliac joint flexibility during asymmetric moment application to the pelvis.

    PubMed

    Gnat, Rafael; Spoor, Kees; Pool-Goudzwaard, Annelies

    2015-10-01

    The role of so-called local muscle system in motor control of the lower back and pelvis is a subject of ongoing debate. Prevailing beliefs in stabilizing function of this system were recently challenged. This study investigated the impact of in vitro simulated force of transversely oriented fibres of the transversus abdominis muscle (a part of the local system) on flexibility of the sacroiliac joint during asymmetric moment application to the pelvis. In 8 embalmed specimens an incremental moment was applied in the sagittal plane to one innominate with respect to the fixed contralateral innominate. Ranges of motion of the sacroiliac joint were recorded using the Vicon Motion Capture System. Load-deformation curves were plotted and flexibility of the sacroiliac joint was calculated separately for anterior and posterior rotations of the innominate, with and without simulated muscle force. Flexibility of the sacroiliac joint was significantly bigger during anterior rotation of the innominate, as compared to posterior rotation (Anova P<0.05). After application of simulated force of transversus abdominis, flexibility of the joint did not change both during anterior and posterior rotations of the innominate. A lack of a stiffening effect of simulated transversus abdominis force on the sacroiliac joint was demonstrated. Earlier hypotheses suggesting a stiffening influence of this muscle on the pelvis cannot be confirmed. Consistent with previous findings smaller flexibility of the joint recorded during posterior rotation of the innominate may be of clinical importance for physio- and manual therapists. However, major limitations of the study should be acknowledged: in vitro conditions and simulation of only solitary muscle force. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Laparoscopic Harvest of the Rectus Abdominis for Perineal Reconstruction

    PubMed Central

    Agochukwu, Nneamaka; Bonaroti, Alisha; Beck, Sandra

    2017-01-01

    Summary: The rectus abdominis is a workhorse flap for perineal reconstruction, in particular after abdominoperineal resection (APR). Laparoscopic and robotic techniques for abdominoperineal surgery are becoming more common. The open harvest of the rectus abdominis negates the advantages of these minimally invasive approaches. (Sentence relating to advantages of laparoscopic rectus deleted here.) We present our early experience with laparoscopic harvest of the rectus muscle for perineal reconstruction. Three laparoscopic unilateral rectus abdominis muscle harvests were performed for perineal reconstruction following minimally invasive colorectal and urological procedures. The 2 patients who underwent APR also had planned external perineal skin reconstruction with local flaps. (Sentence deleted here to shorten abstract.) All rectus muscle harvests were performed laparoscopically. Two were for perineal reconstruction following laparoscopic APR, and 1 was for anterior vaginal wall reconstruction. This was done with 4 ports positioned on the contralateral abdomen. The average laparoscopic harvest time was 60–90 minutes. The rectus muscle remained viable in all cases. One patient developed partial necrosis of a posterior thigh fasciocutaneous flap after cancer recurrence. There were no pelvic abscesses, or abdominal wall hernias. Laparoscopic harvest of the rectus appears to be a cost-effective, reliable, and reproducible procedure for perineal with minimal donor-site morbidity. Larger clinical studies are needed to further establish the efficacy and advantages of the laparoscopic rectus for perineal reconstruction. PMID:29263976

  10. Peritoneal Dialysis Catheter Insertion.

    PubMed

    Crabtree, John H; Chow, Kai-Ming

    2017-01-01

    The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Accuracy of external ventricular drainage catheter placement.

    PubMed

    Abdoh, Mohammad Ghazi; Bekaert, Olivier; Hodel, Jérôme; Diarra, Salia Mamadou; Le Guerinel, Caroline; Nseir, Rémi; Bastuji-Garin, Sylvie; Decq, Philippe

    2012-01-01

    External ventricular drainage (EVD) is a freehand neurosurgical procedure performed routinely using the anatomical landmarks. The aim of this study was to determine the accuracy of EVD catheter freehand placement. Pre-operative and post-operative computed tomography scans for 66 consecutive EVDs performed in 56 adult patients (26 men, 30 women) in 2008 were retrospectively reviewed. Etiologies of acute hydrocephalus were subarachnoid or intraventricular haemorrhage (43 cases) or miscellaneous (13 cases). Pre-operative lateral ventricular volume, position of the burr hole, length of the catheter and its sagittal and coronal angular variations from a theoretical trajectory were measured. The EVD was placed on the right (53 cases) or left (13 cases) side. The mean pre-operative lateral ventricular volume was 51 cc (10-118 cc). The average distance from the burr hole to the midline was 28 mm (10-49 mm) and to the supra-orbital ridge was 101 mm (75-125 mm). The mean intracranial catheter length was 60 mm (from 39-102 mm). Only 50% of the EVDs in the coronal plane and 40% in the sagittal plane were placed with an angular variation of ±5° to the target. The tip was placed outside of the ventricles in three cases; 13 catheters crossed the midline, and five intracranial minor haemorrhages were detected. Freehand placement of EVDs does not have sufficient accuracy and may lead to drainage dysfunctions. This data suggests that a guidance system for EVD's would be required.

  12. Endoscopic Rectus Abdominis and Prepubic Aponeurosis Repairs for Treatment of Athletic Pubalgia.

    PubMed

    Matsuda, Dean K; Matsuda, Nicole A; Head, Rachel; Tivorsak, Tanya

    2017-02-01

    Review of the English orthopaedic literature reveals no prior report of endoscopic repair of rectus abdominis tears and/or prepubic aponeurosis detachment. This technical report describes endoscopic reattachment of an avulsed prepubic aponeurosis and endoscopic repair of a vertical rectus abdominis tear immediately after endoscopic pubic symphysectomy for coexistent recalcitrant osteitis pubis as a single-stage outpatient surgery. Endoscopic rectus abdominis repair and prepubic aponeurosis repair are feasible surgeries that complement endoscopic pubic symphysectomy for patients with concurrent osteitis pubis and expand the less invasive options for patients with athletic pubalgia.

  13. Ultrasound Assessment of the Transverse Abdominis During Functional Movement.

    PubMed

    Mangum, L Colby; Henderson, Kaitlin; Murray, Kyle P; Saliba, Susan A

    2018-05-01

    The traditional activation ratio divides contracted muscle thickness by resting muscle thickness while an abdominal draw-in maneuver is performed during hook lying. Ultrasound imaging during function, such as standing or gait, or peak knee flexion in a single-leg squat allows for further visualization of muscle activity. The goal of this study was to examine activation ratio calculations for transverse abdominis function in supine versus loaded conditions to determine the most informative normalization strategy for muscle activity based on thickness values. Transverse abdominis thickness was measured via ultrasound in 35 healthy participants under 4 different conditions. Comparisons were made between the traditional activation ratio tabletop, standing activation ratio (standing abdominal draw-in maneuver thickness/quiet standing thickness), and functional activation ratio (single-leg squat thickness/quiet standing thickness). Additionally, a cued activation ratio (single-leg squat with cued abdominal draw-in maneuver thickness/single-leg squat thickness) during the single-leg squat was obtained. Activation ratios of greater than 1.0 indicated that participants could activate the muscle during activity, and values were compared by analysis of variance. The participants included 23 women and 12 men with a mean age ± SD of 21.3 ± 2.7 years, mass of 66.1 ± 14.4 kg, and height of 168.5 ± 10.1 cm. Activation ratios exceeded 1.0 in 94.3% for the traditional activation ratio, 85.7% for the standing activation ratio, 82.9% for the cued activation ratio, and 82.9% for the functional activation ratio. With groups defined as tabletop activated or not, the standing, cued, and functional activation ratios were all significantly different (all P < .05). Normalizing muscle thickness to the corresponding functional position quiet value provides a useful functional activation ratio and may help clinicians better understand the transverse abdominis role

  14. Suprapubic catheter care

    MedlinePlus

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  15. Magnetic Catheter Manipulation in the Interventional MRI Environment

    PubMed Central

    Wilson, Mark W.; Martin, Alastair B.; Lillaney, Prasheel; Losey, Aaron D.; Yee, Erin J.; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L.; Hetts, Steven W.

    2013-01-01

    Purpose To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional MRI environment. Materials and Methods Copper coils were mounted on the tips of commercially available 2.3 – 3.0 Fr microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (solenoid) and saddle-shaped (Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5T clinical MRI scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane utilizing a “real-time” steady-state free precession (SSFP) MRI sequence. Degree of deflection and catheter tip orientation were measured for each current application. Results The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Conclusion Controlled catheter deflection is possible with laser lithographed multi-axis coil tipped catheters in the MRI environment. PMID:23707097

  16. Magnetic catheter manipulation in the interventional MR imaging environment.

    PubMed

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  17. Myositis with antimitochondrial antibodies diagnosed by rectus abdominis muscle biopsy.

    PubMed

    Uenaka, Takeshi; Kowa, Hisatomo; Sekiguchi, Kenji; Nagata, Kakuya; Ohtsuka, Yoshihisa; Kanda, Fumio; Toda, Tatsushi

    2013-05-01

    Antimitochondrial antibodies are autoantibodies detected in 90% of primary biliary cirrhosis (PBC) patients. Some PBC cases are complicated by myositis, which is difficult to confirm due to minimal histological evidence of inflammation in limb muscles. Our aim was to determine the extent of inflammatory changes in a truncal muscle biopsy specimen from a PBC patient. A 48-year-old woman with a 5-year history of atrial fibrillation and chronic heart failure was evaluated for elevated serum creatine kinase level. Antimitochondrial M2 antibodies were detected, and PBC was diagnosed. A biceps brachii biopsy specimen showed mild, non-specific myogenic changes; a second biopsy was performed on the rectus abdominis muscle, which showed typical inflammatory changes. Myositis with antimitochondrial M2 antibodies was confirmed. In myositis patients with antimitochondrial M2 antibodies, muscles of the extremities are involved to a lesser extent. Radiological and histological examination focusing on truncal muscles, including a biopsy, is important. Copyright © 2012 Wiley Periodicals, Inc.

  18. [Urinary catheter biofilm infections].

    PubMed

    Holá, V; Růzicka, F

    2008-04-01

    Urinary tract infections, most of which are biofilm infections in catheterized patients, account for more than 40% of hospital infections. Bacterial colonization of the urinary tract and catheters causes not only infection but also other complications such as catheter blockage by bacterial encrustation, urolithiasis and pyelonephritis. About 50% of long-term catheterized patients face urinary flow obstruction due to catheter encrustation, but no measure is currently available to prevent it. Encrustation has been known either to result from metabolic dysfunction or to be of microbial origin, with urease positive bacterial species implicated most often. Infectious calculi account for about 15-20% of all cases of urolithiasis and are often associated with biofilm colonization of a long-term indwelling urinary catheter or urethral stent. The use of closed catheter systems is helpful in reducing such problems; nevertheless, such a system only delays the inevitable, with infections emerging a little later. Various coatings intended to prevent the bacterial adhesion to the surface of catheters and implants and thus also the emergence of biofilm infections, unfortunately, do not inhibit the microbial adhesion completely and permanently and the only reliable method for biofilm eradication remains the removal of the foreign body from the patient.

  19. Bladder Morphology Using 2 Different Catheter Designs

    ClinicalTrials.gov

    2017-04-10

    Urologic Injuries; Urologic Diseases; Bladder Infection; Urinary Tract Infections; Mucosal Inflammation; Mucosal Infection; Bladder Injury; Catheter-Related Infections; Catheter Complications; Catheter; Infection (Indwelling Catheter); Pelvic Floor Disorders; Urinary Incontinence

  20. Heuristic estimation of electromagnetically tracked catheter shape for image-guided vascular procedures

    NASA Astrophysics Data System (ADS)

    Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.

    2014-03-01

    In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.

  1. Central Venous Catheter (Central Line)

    MedlinePlus

    ... the skin entry site. With care, central venous catheters can remain in the body for several months without becoming infected. ■ ■ Blocking or kinking— Blood clots may begin to form in the catheter but ...

  2. Rectus abdominis overuse injury in a tennis athlete treated with traumeel.

    PubMed

    Natsis, Konstantinos; Lyrtzis, Christos; Papathanasiou, Efthymia; Anastasopoulos, Nikos

    2012-01-01

    Rectus abdominis injuries are common in tennis players at all levels of competition. Traumeel(®) injection can be used for treatment of muscle strains and hematomas. A 21-year-old female tennis athlete was injured on the non-dominant rectus abdominis during the cocking phase of the service motion. She suffered from pain and tenderness. One week later, during a serve, she experienced severe pain on the contralateral side of her abdomen. Conservative treatment was performed by the team physician with rest, ice therapy and analgesics for 20 days, but she had recurrent injuries. The ultrasonography and MRI showed hematoma of the rectus abdominis muscle. She was treated with 2 injections of Traumeel(®) on the 2(nd), 4(th), 6(th) post-traumatic day and received 1 injection on the 10(th) post-traumatic day. She also modified her serve technique. On the fourth post-treatment week the athlete had pain-free function and both the MRI appearance and the size of rectus abdominal muscle were normal. She returned to her sport activities. There is no recurrence of her injury 2 years later. Rectus abdominis hematoma must be diagnosed early. Traumeel(®) injections are effective, safe and well-tolerated for the treatment of overuse injury of the rectus abdominis following strain.

  3. An Intelligent Catheter System Robotic Controlled Catheter System

    PubMed Central

    Negoro, M.; Tanimoto, M.; Arai, F.; Fukuda, T.; Fukasaku, K.; Takahashi, I.; Miyachi, S.

    2001-01-01

    Summary We have developed a novel catheter system, an intelligent catheter system, which is able to control a catheter by an externally-placed controller. This system has made from master-slave mechanism and has following three components; 1) a joy stick as a master (for operators) 2)a catheter controller as a slave (for a patient),3)a micro force sensor as a sensing device. This catheter tele-guiding system has abilities to perform intravascular procedures from the distant places. It may help to reduce the radiation exposures to the operators and also to help train young doctors. PMID:20663387

  4. Diastasis of rectus abdominis muscles in low back pain patients.

    PubMed

    Doubkova, Lucie; Andel, Ross; Palascakova-Springrova, Ingrid; Kolar, Pavel; Kriz, Jiri; Kobesova, Alena

    2018-02-06

    Abdominal muscles are important spinal stabilizers and its poor coordination, as seen in diastasis of rectus abdominis (DRA), may contribute to chronic low back pain (LBP). However, this has not yet been studied directly. To conduct a pilot study to examine the association between DRA and LBP. Using a digital caliper, standard clinical DRA measurement was performed in 55 participants with and 54 without chronic LBP. Participants were on average 55 years old, 69 (63%) were women. Among the 16 participants with DRA, 11 (69%) had chronic LBP; among the 93 participants without DRA, 44 (47%) had LBP. Among men, 7 of 9 (77%) with DRA had LBP and 14 of 31 (45%) without DRA had LBP. Among women, 4 of 7 (57%) with DRA had LBP and 30 of 62 (48%) without DRA had LBP. BMI was the strongest correlate of DRA and may explain the relation between DRA and chronic LBP. DRA and LBP may be interrelated, especially among men. This may be a function of greater BMI in individuals with chronic LBP. Understanding the association between DRA, LBP, and BMI may have important implications for treatment of LBP and for intervention.

  5. Catheter-associated UTI

    MedlinePlus

    ... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  6. Central venous catheter - flushing

    MedlinePlus

    ... on a pair of sterile gloves. Remove the cap on the saline syringe and set the cap down on the paper towel. DO NOT let ... It is a good idea to change the caps at the end of your catheter (called the " ...

  7. Comparative analysis of the pressure profilometry of vesicocutaneous continent catheterizable conduits between patients with and without rectus abdominis neosphincter (Yachia principle).

    PubMed

    Rondon, Atila; Leslie, Bruno; Arcuri, Leonardo Javier; Ortiz, Valdemar; Macedo, Antonio

    2015-09-01

    To assess whether crossing rectus abdominis muscle strips, as proposed by Yachia, would change urinary catheterizable conduit's pressure profilometry, in static and dynamic conditions. Non-randomized selection of 20 continent patients that underwent Macedo's ileum-based reservoir, 10 including Yachia's technique (Study Group) and 10 without this mechanism of continence (Control Group). Demographics and cystometric data were assessed. Conduit's pressure profilometry was obtained by infusing saline through a multichannel catheter, at rest and during Valsalva maneuver. We assessed the pressure: (a) in the bladder; (b) in conduit's proximal segment; and (c) in conduit's distal segment, which is presumably the abdominal wall and crossed muscle strips site. Mean age at surgery was 6.1 years in the Control Group and 7.7 years in the Study Group. There was no statistically significant difference between groups regarding maximum cystometric bladder capacity and leakage point pressure. At rest, the pressure profilometry showed similar results between groups in all segments analyzed. During Valsalva maneuver, pressure profilometry showed similar results between groups in bladder and conduit's proximal segment pressure. In this condition, conduit's distal segment pressure in the Study Group (Mean = 72.9 and Peak = 128.7 cmH2 O) was significantly greater (P < 0.05) than conduit's distal segment pressure in the Control Group (Mean = 48.3 and Peak = 65.1 cmH2 O). Crossing muscle strips over the conduit significantly increases the pressure in its distal segment during contraction of the rectus abdominis muscle, which can be important in moments of sudden increase in abdominal pressure in order to keep continence. © 2014 Wiley Periodicals, Inc.

  8. Acute urinary retention: which catheter?

    PubMed Central

    Allardice, J. T.; Standfield, N. J.; Wyatt, A. P.

    1988-01-01

    There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory. PMID:3207328

  9. Catheter-related bloodstream infection.

    PubMed

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  10. Blunt transection of rectus abdominis following seatbelt related trauma with associated small and large bowel injury.

    PubMed

    Patel, K; Doolin, R; Suggett, N

    2013-01-01

    Closed rupture of rectus abdominis following seatbelt related trauma is rare. We present the case of a 45 year old female who presented with closed rupture of the rectus abdominis in conjunction with damage to small bowel mesentery and infarction of small and large bowel following a high velocity road traffic accident. Multiple intestinal resections were required resulting in short bowel syndrome and abdominal wall reconstruction with a porcine collagen mesh. Post-operative complications included intra-abdominal sepsis and an enterocutaneous fistula. The presence of rupture of rectus abdominis muscle secondary to seatbelt injury should raise the suspicion of intra-abdominal injury. Our case highlights the need for suspicion, investigation and subsequent surgical management of intra-abdominal injury following identification of this rare consequence of seatbelt trauma. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Donor-Site Complications and Remnant of Rectus Abdominis Muscle Status after Transverse Rectus Abdominis Myocutaneous Flap Reconstruction

    PubMed Central

    Chirappapha, Prakasit; Trikunagonvong, Noppadol; Rongthong, Sasiprapa; Lertsithichai, Panuwat; Sukarayothin, Thongchai; Leesombatpaiboon, Monchai; Panawattanakul, Rujira; Thaweepworadej, Panya

    2017-01-01

    Background: Transverse rectus abdominis myocutaneous (TRAM) flap reconstruction after mastectomy in breast cancer patients has become one of the milestones in breast reconstruction. There are several techniques that have been used in an attempt to minimize untoward complications. We present the whole muscle with partial sheath-sparing technique that focuses on the anatomy of arcuate line and the closure of the anterior abdominal wall techniques with mesh and determine factors associated with its complications and outcomes. Methods: We retrospectively and prospectively review the results of 30 pedicled TRAM flaps that were performed between November 2013 and March 2016, focusing on outcomes and complications. Results: Among the 30 pedicled TRAM flap procedures in 30 patients, there were complications in 5 patients (17%). Most common complications were surgical-site infection (7%). After a median follow-up time of 15 months, no patient developed abdominal wall hernia or bulging in daily activities in our study, but 6 patients (20%) had asymptomatic abdominal wall bulging when exercised. Significant factors related to asymptomatic exercised abdominal wall bulging included having a body mass index of more than 23 kg/m2. Conclusion: Pedicled TRAM flap by using the technique of the whole muscle with partial sheath-sparing technique combined with reinforcement above the arcuate line with mesh can reduce the occurrence of abdominal bulging and hernia. PMID:28740793

  12. Catheter associated urinary tract infections

    PubMed Central

    2014-01-01

    Urinary tract infection attributed to the use of an indwelling urinary catheter is one of the most common infections acquired by patients in health care facilities. As biofilm ultimately develops on all of these devices, the major determinant for development of bacteriuria is duration of catheterization. While the proportion of bacteriuric subjects who develop symptomatic infection is low, the high frequency of use of indwelling urinary catheters means there is a substantial burden attributable to these infections. Catheter-acquired urinary infection is the source for about 20% of episodes of health-care acquired bacteremia in acute care facilities, and over 50% in long term care facilities. The most important interventions to prevent bacteriuria and infection are to limit indwelling catheter use and, when catheter use is necessary, to discontinue the catheter as soon as clinically feasible. Infection control programs in health care facilities must implement and monitor strategies to limit catheter-acquired urinary infection, including surveillance of catheter use, appropriateness of catheter indications, and complications. Ultimately, prevention of these infections will require technical advances in catheter materials which prevent biofilm formation. PMID:25075308

  13. [Rotational stability of angiography catheters].

    PubMed

    Schröder, J; Weber, M

    1992-10-01

    Rotatory stability is a parameter that reflects the ability of a catheter to transmit a rotation applied at the outer end to the catheter tip for the purpose of selective probing. A method for measuring the rotatory stability is described, and the results of rotatory stability measurements of 70 different commercially available catheters are reported. There is an almost linear correlation between the rotatory stability and the difference between the respective fourth power of the external and internal diameter or, approximately, to the fourth power of the external diameter for catheters without wire reinforcement. With the same cross-sectional dimensions, the rotatory stability of teflon, polyethylene, and nylon catheters has an approximate ratio of 1:2:4. Wire reinforcement increases rotatory stability by an average factor of about 3. For catheters of calibers 5 F and 6 F, a correlation between the rotatory stability and the weight of the reinforcing wire mesh is apparent.

  14. Dynamic rectus abdominis muscle sphincter for stoma continence: an acute functional study in a dog model.

    PubMed

    Bardoel, J W; Stadelmann, W K; Perez-Abadia, G A; Galandiuk, S; Zonnevijlle, E D; Maldonado, C; Stremel, R W; Tobin, G R; Kon, M; Barker, J H

    2001-02-01

    Fecal stomal incontinence is a problem that continues to defy surgical treatment. Previous attempts to create continent stomas using dynamic myoplasty have had limited success due to denervation atrophy of the muscle flap used in the creation of the sphincter and because of muscle fatigue resulting from continuous electrical stimulation. To address the problem of denervation atrophy, a stomal sphincter was designed using the most caudal segment of the rectus abdominis muscle, preserving its intercostal innervation as well as its vascular supply. The purpose of the present study was to determine whether this rectus abdominis muscle island flap sphincter design could maintain stomal continence acutely. In this experiment, six dogs were used to create eight rectus abdominis island flap stoma sphincters around a segment of distal ileum. Initially, the intraluminal stomal pressures generated by the sphincter using different stimulation frequencies were determined. The ability of this stomal sphincter to generate continence at different intraluminal bowel pressures was then assessed. In all cases, the rectus abdominis muscle sphincter generated peak pressures well above those needed to maintain stomal continence (60 mmHg). In addition, each sphincter was able to maintain stomal continence at all intraluminal bowel pressures tested.

  15. Sexual dysfunction after colpectomy and vaginal reconstruction with a vertical rectus abdominis myocutaneous flap.

    PubMed

    Løve, Uffe S; Sjøgren, Pia; Rasmussen, Peter; Laurberg, Søren; Christensen, Henrik K

    2013-02-01

    The use of the vertical rectus abdominis myocutaneous flap in reconstruction after abdominoperineal resection or pelvic exenteration for neoplasia is well documented. However, functional outcomes after vaginal reconstruction, including sexual function, are poorly described. This study aimed to examine sexual function in women following extensive pelvic surgery with colpectomy and vaginal reconstruction with the use of a vertical rectus abdominis myocutaneous flap. This study is a retrospective review of medical records in combination with patient questionnaires. Nonresponders were followed up with a second contact. This study was performed at a tertiary care university medical center (Colorectal Section, Department of Surgery P, Aarhus University Hospital, Denmark) All women undergoing pelvic surgery and simultaneous vaginal reconstruction with the use of a vertical rectus abdominis myocutaneous flap between 2004 and 2010 at our department were identified from a patient database. Thirty women who were alive at the time of identification were included in the study. Sexual function before and after surgery was evaluated by the use of the Sexual function Vaginal changes Questionnaire. The main outcome end point was whether the patient was sexually active after vaginal reconstruction. Twenty-six participants (87%) answered the questionnaire. Fifty percent of patients reported an active sex life before surgery. In general, patients reported an unchanged desire for both physical and sexual contact after surgery. However, only 2 patients (14%) reported being sexually active after surgery. This was a retrospective study with a heterogeneous cohort involving several types of cancers and surgical procedures. Factors other than vertical rectus abdominis myocutaneous flap reconstruction itself may interfere with the sexual function. Extensive pelvic surgery with colpectomy leads to sexual dysfunction even when the vagina is reconstructed with a vertical rectus abdominis

  16. Heart catheter cable and connector

    NASA Technical Reports Server (NTRS)

    Harrison, D. R.; Cota, F. L.; Sandler, H.

    1972-01-01

    Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.

  17. Pedicled rectus abdominis muscle and fascia flap sling the bulbar urethra for treatment for male-acquired urinary incontinence: report of ten cases.

    PubMed

    Xu, Yue-Min; Zhang, Xin-Ru; Xie, Hong; Song, Lu-Jie; Feng, Chao; Fei, Xiao-Fang

    2014-03-01

    Male urinary incontinence is relatively common complication of radical prostatectomy and of posterior urethroplasty following traumatic pelvic fracture. Here, we investigate the use of pedicled rectus abdominis muscle and fascia flap sling of the bulbar urethra for treatment for male-acquired urinary incontinence. Ten patients with acquired urinary incontinence were included in the study. Urinary incontinence was secondary to TURP in three patients and was secondary to posterior urethroplasty performed following traumatic pelvic fracture in seven patients. Pedicled rectus abdominalis muscle and fascial flaps, approximately 2.5 cm wide and 15 cm long, were isolated. The flaps were inserted into a perineal incision through a subcutaneous tunnel. The free end of the flap was sectioned to form two muscle strips, each 3 cm in length, and inserted into the space between bulbar urethra and corpus cavernosa. After adequate sling tension had been achieved, the two strips of muscle were anastomosed around the bulbar urethra using a 2-zero polyglactin suture. The patients were followed up for between 12 and 82 months (mean 42.8 months). Complete continence was achieved with good voiding in seven of the 10 patients. In other three patients achieved good voiding following catheter removal, but incontinence was only moderately improved. A pedicled rectus muscle fascial sling of the bulbar urethra is an effective and safe treatment for male patients with mild to moderate acquired urinary incontinence, but it may not be suitable for severe incontinence or for patients with weak rectus abdominalis muscles.

  18. Toxicity testing of urinary catheters.

    PubMed

    Talja, M; Andersson, L C; Ruutu, M; Alfthan, O

    1985-10-01

    The tissue toxicity of 23 urinary catheter batches (6 latex and 2 non-latex brands) was tested in vitro and in vivo. In vitro, a human T-cell leukemia line (JM) was cultured in the presence of different concentrations of eluates made from the catheters. The cytotoxicity of the eluates was assessed from their ability to inhibit DNA synthesis measured by incorporation of 3H-thymidine. In vivo, two methods were used. Strips of catheters were implanted into the rabbit dorsal muscle and pieces of catheters were implanted into the rat peritoneal cavity. After four days, the foreign body reaction, type of inflammation and necrosis were quantified macroscopically and by light microscopy. The results of the in vitro cytotoxicity test were correlated with those of in vivo methods. The rat peritoneal implantation test correlated better with the cell culture test (P less than 0.01) than with the rabbit muscle implantation test (P less than 0.05). Based on the clinical experience of urethral stricture complications caused by urinary catheters, catheters yielding eluate which at 30% dilution inhibited 50% DNA synthesis were regarded as toxic. According to this, the rabbit muscle implantation test was not reliable in testing the tissue toxicity of urinary catheters, while the cell culture test was quantitative and seemed to correlate with both the rat peritoneal implantation test and with the clinical complications observed.

  19. Exercise and Transversus Abdominis Muscle Atrophy after 60-d Bed Rest.

    PubMed

    Belavý, Daniel Ludovic; Gast, Ulf; Felsenberg, Dieter

    2017-02-01

    This study aimed to investigate atrophy in the deep abdominal muscles, spinal extensors, and the effect of high-load resistive exercise with and without whole-body vibration after 60 d of strict bed rest. Twenty-four subjects underwent 60 d of head-down tilt bed rest and performed either resistive vibration exercise (RVE), resistive exercise only (RE), or no exercise control (2nd Berlin BedRest Study). The thickness of the transversus abdominis, internal oblique, and erector spinae muscles and the area of the multifidus muscle were measured bilaterally via real-time ultrasound. Intention-to-treat analysis was implemented, and P values were adjusted by the false discovery rate method. At the end of the bed rest, transversus abdominis thickness was reduced by 18.3% in the inactive group (P = 0.00011) with no significant change in the RVE (-4.0%; P = 0.014 vs control) or RE (-5.0%; P = 0.10 vs control) groups. In the inactive subjects, internal oblique thickness reduced by 10.6% (P = 0.0025) and by 7% (P > 0.05) in each of the training groups. The lengthening of the lumbar spine was greatest on day 1 (+7.4%, P = 0.004) and day 2 (+6.3%, P = 0.004; day 54: +4.1%, P = 0.023). A 4.7% reduction of multifidus area was observed on day 1 of bed rest (P = 0.0049) and a 4.2% reduction of erector spinae thickness was observed on day 2 (P = 0.0011). Extensor atrophy and spinal lengthening was not affected by exercise. No significant difference was seen between RVE and RE. Bed rest leads to atrophy of the transversus abdominis and internal oblique muscles. The exercise program, which implemented lower-limb and back extension exercises against shoulder restraints, was able to reduce atrophy seen in transversus abdominis in bed rest.

  20. Large asymmetric hypertrophy of rectus abdominis muscle in professional tennis players.

    PubMed

    Sanchis-Moysi, Joaquin; Idoate, Fernando; Dorado, Cecilia; Alayón, Santiago; Calbet, Jose A L

    2010-12-31

    To determine the volume and degree of asymmetry of the musculus rectus abdominis (RA) in professional tennis players. The volume of the RA was determined using magnetic resonance imaging (MRI) in 8 professional male tennis players and 6 non-active male control subjects. Tennis players had 58% greater RA volume than controls (P = 0.01), due to hypertrophy of both the dominant (34% greater volume, P = 0.02) and non-dominant (82% greater volume, P = 0.01) sides, after accounting for age, the length of the RA muscle and body mass index (BMI) as covariates. In tennis players, there was a marked asymmetry in the development of the RA, which volume was 35% greater in the non-dominant compared to the dominant side (P<0.001). In contrast, no side-to-side difference in RA volume was observed in the controls (P = 0.75). The degree of side-to-side asymmetry increased linearly from the first lumbar disc to the pubic symphysis (r = 0.97, P<0.001). Professional tennis is associated with marked hypertrophy of the musculus rectus abdominis, which achieves a volume that is 58% greater than in non-active controls. Rectus abdominis hypertrophy is more marked in the non-dominant than in the dominant side, particularly in the more distal regions. Our study supports the concept that humans can differentially recruit both rectus abdominis but also the upper and lower regions of each muscle. It remains to be determined if this disequilibrium raises the risk of injury.

  1. Soccer Attenuates the Asymmetry of Rectus Abdominis Muscle Observed in Non-Athletes

    PubMed Central

    Idoate, Fernando; Calbet, Jose A. L.; Izquierdo, Mikel; Sanchis-Moysi, Joaquin

    2011-01-01

    Purpose To determine the volume and degree of asymmetry of the rectus abdominis muscle (RA) in professional soccer players. Methods The volume of the RA was determined using magnetic resonance imaging (MRI) in 15 professional male soccer players and 6 non-active male control subjects. Results Soccer players had 26% greater RA volume than controls (P<0.05), due to hypertrophy of both the dominant (28% greater volume, P<0.05) and non-dominant (25% greater volume, P<0.01) sides, after adjusting for age, length of the RA muscle and body mass index (BMI) as covariates. Total volume of the dominant side was similar to the contralateral in soccer players (P = 0.42) and in controls (P = 0.75) (Dominant/non-dominant = 0.99, in both groups). Segmental analysis showed a progressive increase in the degree of side-to-side asymmetry from the first lumbar disc to the pubic symphysis in soccer players (r = 0.80, P<0.05) and in controls (r = 0.75, P<0.05). The slope of the relationship was lower in soccer players, although this trend was not statistically significant (P = 0.14). Conclusions Professional soccer is associated with marked hypertrophy of the rectus abdominis muscle, which achieves a volume that is 26% greater than in non-active controls. Soccer induces the hypertrophy of the non-dominant side in proximal regions and the dominant side in regions closer to pubic symphysis, which attenuates the pattern of asymmetry of rectus abdominis observed in non-active population. It remains to be determined whether the hypertrophy of rectus abdominis in soccer players modifies the risk of injury. PMID:21541351

  2. Use of the rectus abdominis muscle for abdominal stoma sphincter construction: an anatomical feasibility study.

    PubMed

    Bardoel, J W; Stadelmann, W K; Tobin, G R; Werker, P M; Stremel, R W; Kon, M; Barker, J H

    2000-02-01

    Permanent fecal abdominal stomas significantly decrease quality of life. Previous attempts to create continent stomas by using dynamic myoplasty procedures have resulted in disappointing outcomes, primarily owing to denervation atrophy of the muscle flap that was used in the creation of the sphincter and because of muscle fatigue resulting from continuous electrical stimulation that is received by the flap to force contraction. On the basis of these problems, we designed two separate studies: an anatomical study addressing flap denervation and a functional study addressing muscle fatigue. The present study addresses the first topic and was designed to develop a rectus abdominis muscle flap into a sphincter that was anatomically situated to create a stoma while preserving as much innervation as possible. In 24 rectus abdominis muscles of human cadavers, the neurovascular anatomy was defined, then the anatomical feasibility of two different muscle flap configurations was considered. The flaps investigated were the peninsula flap and island flap designs, with both using the most caudal segment of the rectus abdominis muscle in construction of the sphincter. Neither flap design required the killing of a nerve for stoma sphincter creation, resulting in minimal muscle denervation. The conclusion of our comparison was that the above, in conjunction with other features of the island flap design, such as muscle overlap after sphincter formation and abdominal wall positioning of the sphincter, made the island flap design better suited to stoma sphincter construction.

  3. Central venous catheter - dressing change

    MedlinePlus

    ... will need: Sterile gloves Cleaning solution A special sponge A special patch, called a Biopatch A clear ... around the catheter. Clean the skin with the sponge and cleaning solution. Air dry after cleaning. Place ...

  4. Large eccentric laser angioplasty catheter

    NASA Astrophysics Data System (ADS)

    Taylor, Kevin D.; Reiser, Christopher

    1997-05-01

    In response to recent demand for increased debulking of large diameter coronary vascular segments, a large eccentric catheter for excimer laser coronary angioplasty has been developed. The outer tip diameter is 2.0 mm and incorporates approximately 300 fibers of 50 micron diameter in a monorail- type percutaneous catheter. The basic function of the device is to ablate a coronary atherosclerotic lesion with 308 nm excimer laser pulses, while passing the tip of the catheter through the lesion. By employing multiple passes through the lesion, rotating the catheter 90 degrees after each pass, we expect to create luminal diameters close to 3 mm with this device. Design characteristics, in-vitro testing, and initial clinical experience is presented.

  5. Compensation for Unconstrained Catheter Shaft Motion in Cardiac Catheters

    PubMed Central

    Degirmenci, Alperen; Loschak, Paul M.; Tschabrunn, Cory M.; Anter, Elad; Howe, Robert D.

    2016-01-01

    Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures. PMID:27525170

  6. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    PubMed

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  7. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This..., coude catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters...

  8. Management of obstructed balloon catheters.

    PubMed Central

    Browning, G G; Barr, L; Horsburgh, A G

    1984-01-01

    Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691

  9. Catheter-based photoacoustic endoscope

    PubMed Central

    Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2014-01-01

    Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743

  10. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... (a) Identification. An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to...

  11. Normal postural responses preceding shoulder flexion: co-activation or asymmetric activation of transverse abdominis?

    PubMed

    Davarian, Sanaz; Maroufi, Nader; Ebrahimi, Esmaeil; Parnianpour, Mohammad; Farahmand, Farzam

    2014-01-01

    It is suggested that activation of the transverse abdominis muscle has a stabilizing effect on the lumbar spine by raising intra-abdominal pressure without added disc compression. However, its feedforward activity has remained a controversial issue. In addition, research regarding bilateral activation of trunk muscles during a unilateral arm movement is limited. The aim of this study was to evaluate bilateral anticipatory activity of trunk muscles during unilateral arm flexion. Eighteen healthy subjects (aged 25 ± 3.96 years) participated in this study and performed 10 trials of rapid arm flexion in response to a visual stimulus. The electromyographic activity of the right anterior deltoid (AD) and bilateral trunk muscles including the transverse abdominis/internal oblique (TA/IO), superficial lumbar multifidus (SLM) and lumbar erector spine (LES) was recorded. The onset latency and anticipatory activity of the recorded trunk muscles were calculated. The first muscle activated in anticipation of the right arm flexion was the left TA/IO. The right TA/IO activated significantly later than all other trunk muscles (P < 0.0005). In addition, anticipatory activity of the right TA/IO was significantly lower than all other trunk muscles (P < 0.0005). There was no significant difference in either onset latency or anticipatory activity among other trunk muscles (P > 0.05). Healthy subjects showed no bilateral anticipatory co-activation of TA/IO in unilateral arm elevation. Further investigations are required to delineate normal muscle activation pattern in healthy subjects prior to prescribing bilateral activation training of transverse abdominis for subjects with chronic low back pain.

  12. Free tissue transfer of the rectus abdominis myoperitoneal flap for oral reconstruction in a dog.

    PubMed

    Lanz, O I

    2001-12-01

    A five-month-old intact/male Boxer dog was presented 5-days following bite wound trauma to the maxillary region resulting in an oronasal fistula extending from the maxillary canine teeth to the soft palate. Multiple surgical procedures using local, buccal mucosal flaps failed to repair the oronasal fistula. Free tissue transfer of the rectus abdominis myoperitoneal flap using microvascular surgical techniques was successful in providing soft tissue reconstruction of the hard palate area. Complications of these surgical techniques included muscle contraction and subsequent muzzle distortion. Small, refractory oronasal fistulae at the perimeter of the myoperitoneal flap were repaired by primary wound closure.

  13. Determining the best catheter for sonohysterography.

    PubMed

    Dessole, S; Farina, M; Capobianco, G; Nardelli, G B; Ambrosini, G; Meloni, G B

    2001-09-01

    To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost. Prospective study. University hospital. Six hundred ten women undergoing SHG. We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN). We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters. In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive. The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.

  14. Echogenic Catheters and Embryo Transfer Standardization.

    PubMed

    Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge

    2015-05-01

    1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.

  15. Catheter-related bloodstream infections

    PubMed Central

    Gahlot, Rupam; Nigam, Chaitanya; Kumar, Vikas; Yadav, Ghanshyam; Anupurba, Shampa

    2014-01-01

    Central-venous-catheter-related bloodstream infections (CRBSIs) are an important cause of hospital-acquired infection associated with morbidity, mortality, and cost. Consequences depend on associated organisms, underlying pre-morbid conditions, timeliness, and appropriateness of the treatment/interventions received. We have summarized risk factors, pathogenesis, etiology, diagnosis, and management of CRBSI in this review. PMID:25024944

  16. Peripherally inserted central catheter - flushing

    MedlinePlus

    ... on a pair of sterile gloves. Remove the cap on the saline syringe and set the cap down on the paper towel. DO NOT let ... It is a good idea to change the caps at the end of your catheter (called the " ...

  17. Making planes plain.

    PubMed

    O'Rahilly, R

    1997-01-01

    The major anatomical planes (horizontal, coronal, and sagittal, including the median plane) are discussed from a historical perspective, and their correct usage is clarified. Unofficial and unnecessary terms to be avoided (for reasons explained) include midsagittal, parasagittal, and midline.

  18. Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.

    PubMed

    Knight, Bradley; Ayers, Gregory M; Cohen, Todd J

    2008-05-01

    Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial

  19. Rectus abdominis muscle injuries in elite handball players: management and rehabilitation

    PubMed Central

    Balius, Ramon; Pedret, Carles; Pacheco, Laura; Gutierrez, Josep Antoni; Vives, Joan; Escoda, Jaume

    2011-01-01

    Muscle injuries generally occur in two-joint muscles with a high percentage of type II fibers during the performance of eccentric activity. Some muscle injuries, such as those located in the adductor longus, a monoarticular muscle, as well as rectus abdominis do not fully comply with these requirements. This study examines five cases of elite handball players with ruptured rectus abdominals. Sonographically, lesions in rectus abdominis are shown as a disruption of the fibrillar pattern with a hematic suffusion that invades the entire lesion. In some of the cases, the ultrasound study was complemented with a MRI. A unified rehabilitation protocol was applied and the return to play time of each handball player ranged between 16 and 22 days, with an average of 18.2 days. Follow-up at 15 months showed no evidence of re-injury or residual discomfort and all of them are playing at their highest level. The aim of this study was to illustrate a feature of handball injury that, as in tennis and volleyball, is uncommon and so far has not been specifically reported. The phenomenon of contralateral abdominal hypertrophy in handball appears in the dominant arm as in tennis and volleyball. PMID:24198573

  20. Right Lower Quadrant Pain in a Young Female: Ultrasound Diagnosis of Rectus Abdominis Tear.

    PubMed

    Minardi, Joseph; Shaver, Erica; Monseau, Aaron; Pratt, Adam; Layman, Shelley M

    2015-11-01

    Right lower quadrant pain in young females presents a frequent diagnostic challenge for emergency physicians, with a broad differential and several important diagnoses. Using an "ultrasound first" imaging strategy can help decrease the use of computed tomography scans, with associated savings in radiation exposure, cost, and other resource use. We report a case of right lower quadrant pain in a young woman. After her initial history and physical examination, appendicitis was the leading differential. A bedside ultrasound was performed, leading to the uncommon diagnosis of rectus abdominis muscle tear. The sonographic findings of a muscle tear include increase in size, loss of linear, homogeneous architecture, and decreased echogenicity. Making this diagnosis at the bedside using ultrasound obviated the need for further imaging, avoiding unnecessary radiation exposure, and decreasing emergency department length of stay and overall cost, while leading to a tailored treatment plan. Why Should an Emergency Physician Be Aware of This? Rectus abdominis tear is a cause of right lower quadrant pain that may mimic appendicitis and should be considered in patients with this complaint. The ability to make this diagnosis with bedside ultrasound may assist in several important patient-oriented outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. SU-E-T-362: Automatic Catheter Reconstruction of Flap Applicators in HDR Surface Brachytherapy

    SciTech Connect

    Buzurovic, I; Devlin, P; Hansen, J

    2014-06-01

    Purpose: Catheter reconstruction is crucial for the accurate delivery of radiation dose in HDR brachytherapy. The process becomes complicated and time-consuming for large superficial clinical targets with a complex topology. A novel method for the automatic catheter reconstruction of flap applicators is proposed in this study. Methods: We have developed a program package capable of image manipulation, using C++class libraries of The-Visualization-Toolkit(VTK) software system. The workflow for automatic catheter reconstruction is: a)an anchor point is placed in 3D or in the axial view of the first slice at the tip of the first, last and middle points for the curvedmore » surface; b)similar points are placed on the last slice of the image set; c)the surface detection algorithm automatically registers the points to the images and applies the surface reconstruction filter; d)then a structured grid surface is generated through the center of the treatment catheters placed at a distance of 5mm from the patient's skin. As a result, a mesh-style plane is generated with the reconstructed catheters placed 10mm apart. To demonstrate automatic catheter reconstruction, we used CT images of patients diagnosed with cutaneous T-cell-lymphoma and imaged with Freiburg-Flap-Applicators (Nucletron™-Elekta, Netherlands). The coordinates for each catheter were generated and compared to the control points selected during the manual reconstruction for 16catheters and 368control point Results: The variation of the catheter tip positions between the automatically and manually reconstructed catheters was 0.17mm(SD=0.23mm). The position difference between the manually selected catheter control points and the corresponding points obtained automatically was 0.17mm in the x-direction (SD=0.23mm), 0.13mm in the y-direction (SD=0.22mm), and 0.14mm in the z-direction (SD=0.24mm). Conclusion: This study shows the feasibility of the automatic catheter reconstruction of flap applicators with a high

  2. Insertion of tunneled hemodialysis catheters without fluoroscopy.

    PubMed

    Motta Elias, Rosilene; da Silva Makida, Sonia Cristina; Abensur, Hugo; Martins Castro, Manuel Carlos; Affonso Moysés, Rosa Maria; Pereira, Benedito Jorge; Bueno de Oliveira, Rodrigo; Luders, Cláudio; Romão, João Egidio

    2010-01-01

    The tunneled cuffed catheter (TCC) is used as a bridge access for hemodialysis. Few prospective studies have been designed to evaluate conversion from non-tunneled to TCC without the use of fluoroscopy when performed by nephrologists. We performed an observational prospective cohort in incident patients receiving hemodialysis through a non-tunneled right jugular vein catheter. 130 procedures were performed in 122 patients (51+/-18 years). The success rate was 100%. There was a total of 26,546 catheter days. Ninety-one of the 130 catheters were removed during the study period. Life table analysis revealed primary patency rates of 92%, 82%, and 68% at 30, 60, and 120 days, respectively. Infection requiring catheter removal occurred at a frequency of 0.09 per 100 catheter days. Catheter malfunction requiring intervention occurred at a rate of 0.03 per 100 catheter days. Hypertension and duration of existing non-tunneled catheter of less than 2 weeks were independently associated with better TCC survival. The conversion from non-tunneled to TCC performed by nephrologists and without fluoroscopy may be safe by using the internal right jugular vein. The ideal time to do this procedure is within less than 2 weeks of existing non-tunneled catheter.

  3. Rational choice of peritoneal dialysis catheter.

    PubMed

    Dell'Aquila, Roberto; Chiaramonte, Stefano; Rodighiero, Maria Pia; Spanó, Emilia; Di Loreto, Pierluigi; Kohn, Catalina Ocampo; Cruz, Dinna; Polanco, Natalia; Kuang, Dingwei; Corradi, Valentina; De Cal, Massimo; Ronco, Claudio

    2007-06-01

    The peritoneal catheter should be a permanent and safe access to the peritoneal cavity. Catheter-related problems are often the cause of permanent transfer to hemodialysis (HD) in up to 20% of peritoneal dialysis (PD) patients; in some cases, these problems require a temporary period on HD. Advances in connectology have reduced the incidence of peritonitis, and so catheter-related complications during PD have become a major concern. In the last few years, novel techniques have emerged in the field of PD: new dialysis solutions, better connectology, and cyclers for automated PD. However, extracorporeal dialysis has continued to improve in terms of methods and patient survival, but PD has failed to do so. The main reason is that peritoneal access has remained problematical. The peritoneal catheter is the major obstacle to wide-spread use of PD. Overcoming catheter-related problems means giving a real chance to development of the peritoneal technique. Catheters should be as efficient, safe, and acceptable as possible. Since its introduction in the mid-1960s, the Tenckhoff catheter has not become obsolete: dozens of new models have been proposed, but none has significantly reduced the pre-dominance of the first catheter. No convincing prospective data demonstrate the superiority of any peritoneal catheter, and so it seems that factors other than choice of catheter are what affect survival and complication rates. Efforts to improve peritoneal catheter survival and complication rates should probably focus on factors other than the choice of catheter. The present article provides an overview of the characteristics of the best-known peritoneal catheters.

  4. Use of peripherally inserted central catheters as an alternative to central catheters in neurocritical care units.

    PubMed

    DeLemos, Christi; Abi-Nader, Judy; Akins, Paul T

    2011-04-01

    Patients in neurological critical care units often have lengthy stays that require extended vascular access and invasive hemodynamic monitoring. The traditional approach for these patients has relied heavily on central venous and pulmonary artery catheters. The aim of this study was to evaluate peripherally inserted central catheters as an alternative to central venous catheters in neurocritical care settings. Data on 35 patients who had peripherally inserted central catheters rather than central venous or pulmonary artery catheters for intravascular access and monitoring were collected from a prospective registry of neurological critical care admissions. These data were cross-referenced with information from hospital-based data registries for peripherally inserted central catheters and subarachnoid hemorrhage. Complete data were available on 33 patients with Hunt-Hess grade IV-V aneurysmal subarachnoid hemorrhage. Catheters remained in place a total of 649 days (mean, 19 days; range, 4-64 days). One patient (3%) had deep vein thrombosis in an upper extremity. In 2 patients, central venous pressure measured with a peripherally inserted catheter was higher than pressure measured concurrently with a central venous catheter. None of the 33 patients had a central catheter bloodstream infection or persistent insertion-related complications. CONCLUSIONS Use of peripherally inserted central catheters rather than central venous catheters or pulmonary artery catheters in the neurocritical care unit reduced procedural and infection risk without compromising patient management.

  5. Feedforward responses of transversus abdominis are directionally specific and act asymmetrically: implications for core stability theories.

    PubMed

    Allison, Garry T; Morris, Sue L; Lay, Brendan

    2008-05-01

    Experimental laboratory study supplemented with a repeated case study. To examine bilateral muscle activity of the deep abdominals in response to rapid arm raising, specifically to examine the laterality and directional specificity of feedforward responses of the transversus abdominis (TrA). Based on the feedforward responses of trunk muscles during rapid arm movements, authors have concluded that the deep trunk muscles have different control mechanisms compared to the more superficial muscles. It has been proposed that deep trunk muscles such as TrA contribute substantially to the stability of the lumbar spine and that this is achieved through simultaneous bilateral feedforward activation. These inferences are based on unilateral fine-wire electromyographic (EMG) data and there are limited investigations of bilateral responses of the TrA during unilateral arm raising. Bilateral fine-wire and surface EMG data from the anterior deltoid, TrA, obliquus internus (OI), obliquus externus, biceps femoris, erector spinae, and rectus abdominis during repeated arm raises were recorded at 2 kHz. EMG signal linear envelopes were synchronized to the onset of the anterior deltoid. A feedforward window was defined as the period up to 50 ms after the onset of the anterior deltoid, and paired onsets for bilateral muscles were plotted for both left and right arm movements. Trunk muscles from the group data demonstrated differences between sides (laterality), which were systematically altered when alternate arms were raised (directional specificity). This was clearly evident for the TrA but less obvious for the erector spinae. The ipsilateral biceps femoris and obliquus externus, and contralateral OI and TrA, were activated earlier than the alternate side for both right and left arm movements. This was a consistent pattern over a 7-year period for the case study. Data for the rectus abdominis derived from the case study demonstrated little laterality or directionally specific

  6. The Sierpinski Triangle Plane

    NASA Astrophysics Data System (ADS)

    Ettestad, David; Carbonara, Joaquin

    The Sierpinski Triangle (ST) is a fractal which has Haussdorf dimension log23 ≈ 1.585 that has been studied extensively. In this paper, we introduce the Sierpinski Triangle Plane (STP), an infinite extension of the ST that spans the entire real plane but is not a vector subspace or a tiling of the plane with a finite set of STs. STP is shown to be a radial fractal with many interesting and surprising properties.

  7. Workhorse Flaps in Chest Wall Reconstruction: The Pectoralis Major, Latissimus Dorsi, and Rectus Abdominis Flaps

    PubMed Central

    Bakri, Karim; Mardini, Samir; Evans, Karen K.; Carlsen, Brian T.; Arnold, Phillip G.

    2011-01-01

    Large and life-threatening thoracic cage defects can result from the treatment of traumatic injuries, tumors, infection, congenital anomalies, and radiation injury and require prompt reconstruction to restore respiratory function and soft tissue closure. Important factors for consideration are coverage with healthy tissue to heal a wound, the potential alteration in respiratory mechanics created by large extirpations or nonhealing thoracic wounds, and the need for immediate coverage for vital structures. The choice of technique depends on the size and extent of the defect, its location, and donor site availability with consideration to previous thoracic or abdominal operations. The focus of this article is specifically to describe the use of the pectoralis major, latissimus dorsi, and rectus abdominis muscle flaps for reconstruction of thoracic defects, as these are the workhorse flaps commonly used for chest wall reconstruction. PMID:22294942

  8. Extensive Chest Wall Tissue Loss and its Management by Vertical Rectus Abdominis Myocutaneous Flap

    PubMed Central

    Basu, Sandip Kanti; Bain, Jayanta; Chattopadhyay, Debarati; Majumdar, Bijay Kumar

    2017-01-01

    Extensive electric burn around the chest in children is rare and this type of injury always poses a great challenge for its management. A 12-year-old male child with extensive electric burn of the chest wall was admitted to hospital. It was a neglected case of 9 days old burn; the young boy was in critical condition having systemic features of toxemia with widespread necrosis of the skin, subcutaneous tissues, and muscles along with exposed bones (ribs and sternum) with the risk of impending rupture of pleura through the exposed intercostal spaces. After initial resuscitation, a thorough debridement of all necrotic tissues was done. Thereafter, a superiorly based vertical rectus abdominis myocutaneous flap was harvested to cover the exposed bones and intercostal spaces. The remaining raw areas were skin grafted. The child made an excellent recovery with good outcome. PMID:28082777

  9. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    PubMed

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  10. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration

    PubMed Central

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-01-01

    Objective: Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. Methods: This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. Conclusion: The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance. PMID:25097505

  11. Central venous catheters: legal issues.

    PubMed

    Gallieni, Maurizio; Martina, Valentina; Rizzo, Maria Antonietta; Gravellone, Luciana; Mobilia, Francesca; Giordano, Antonino; Cusi, Daniele; Genovese, Umberto

    2011-01-01

    In dialysis patients, both central venous catheter (CVC) insertion and CVC use during the dialysis procedure pose important legal issues, because of potentially severe, even fatal, complications. The first issue is the decision of the kind of vascular access that should be proposed to patients: an arteriovenous (AV) fistula, a graft, or a CVC. The second issue, when choosing the CVC option, is the choice of CVC: nontunneled versus tunneled. Leaving a temporary nontunneled CVC for a prolonged time increases the risk of complications and could raise a liability issue. Even when choosing a long-term tunneled CVC, nephrologists should systematically explain its potential harms, presenting them as "unsafe for long-term use" unless there is a clear contraindication to an AV native or prosthetic access. Another critical issue is the preparation of a complete, informative, and easy-to-understand consent form. The CVC insertion procedure has many aspects of legal interest, including the choice of CVC, the use of ECG monitoring, the use of ultrasound guidance for cannulation, and the use of fluoroscopy for checking the position of the metal guidewire during the procedure as well as the CVC tip before the end of the procedure. Use of insertion devices and techniques that can prevent complications should obviously be encouraged. Complications of CVC use are mainly thrombosis and infection. These are theoretically expected as pure complications (and not as malpractice effects), but legal issues might relate to inappropriate catheter care (in both the inpatient and outpatient settings) rather than to the event per se. Thus, in the individual case it is indeed very difficult to establish malpractice and liability with a catheter-related infection or thrombosis. In conclusion, we cannot avoid complications completely when using CVCs, but reducing them to a minimum and adopting safe approaches to their insertion and use will reduce legal liability.

  12. FAQs about Catheter-Associated Urinary Tract Infection

    MedlinePlus

    ... and nurses take the following actions. Catheter insertion o Catheters are put in only when necessary and they are removed as soon as possible. o Only properly trained persons insert catheters using sterile (“ ...

  13. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  14. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  15. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  16. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  17. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  18. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  19. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  20. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  1. Tissue elasticity of in vivo skeletal muscles measured in the transverse and longitudinal planes using shear wave elastography.

    PubMed

    Chino, Kentaro; Kawakami, Yasuo; Takahashi, Hideyuki

    2017-07-01

    The aim of the present study was to measure in vivo skeletal muscle elasticity in the transverse and longitudinal planes using shear wave elastography and then to compare the image stability, measurement values and measurement repeatability between these imaging planes. Thirty-one healthy males participated in this study. Tissue elasticity (shear wave velocity) of the medial gastrocnemius, rectus femoris, biceps brachii and rectus abdominis was measured in both the transverse and longitudinal planes using shear wave elastography. Image stability was evaluated by the standard deviation of the colour distribution in the shear wave elastography image. Measurement repeatability was assessed by the coefficient of variance obtained from three measurement values. Image stability of all tested muscles was significantly higher in the longitudinal plane (P<0·001), but measurement repeatability did not differ significantly between the imaging planes (P>0·05), except in the biceps brachii (P = 0·001). Measurement values of the medial gastrocnemius, rectus femoris and biceps brachii were significantly different between the imaging planes (P<0·001). Image stability and measurement values of shear wave elastography images varied with imaging plane, which indicates that imaging plane should be considered when measuring skeletal muscle tissue elasticity by shear wave elastography. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  2. Laser welding of balloon catheters

    NASA Astrophysics Data System (ADS)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  3. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  4. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  5. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  6. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  7. 21 CFR 870.1250 - Percutaneous catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous catheter. 870.1250 Section 870.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1250 Percutaneous catheter...

  8. 21 CFR 870.1380 - Catheter stylet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter stylet. 870.1380 Section 870.1380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1380 Catheter stylet. (a...

  9. 21 CFR 870.1300 - Catheter cannula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter cannula. 870.1300 Section 870.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1300 Catheter cannula. (a...

  10. 21 CFR 870.1280 - Steerable catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a...

  11. 21 CFR 870.1340 - Catheter introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter introducer. 870.1340 Section 870.1340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1340 Catheter introducer...

  12. 21 CFR 870.1380 - Catheter stylet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter stylet. 870.1380 Section 870.1380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1380 Catheter stylet. (a...

  13. 21 CFR 870.1340 - Catheter introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter introducer. 870.1340 Section 870.1340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1340 Catheter introducer...

  14. 21 CFR 870.1280 - Steerable catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a...

  15. 21 CFR 870.1300 - Catheter cannula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter cannula. 870.1300 Section 870.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1300 Catheter cannula. (a...

  16. 21 CFR 870.1250 - Percutaneous catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Percutaneous catheter. 870.1250 Section 870.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1250 Percutaneous catheter...

  17. Outcomes after peritoneal dialysis catheter placement.

    PubMed

    Carpenter, Jennifer L; Fallon, Sara C; Swartz, Sarah J; Minifee, Paul K; Cass, Darrell L; Nuchtern, Jed G; Pimpalwar, Ashwin P; Brandt, Mary L

    2016-05-01

    The purpose of this study was to review surgical outcomes after elective placement of peritoneal dialysis (PD) catheters in children with end-stage renal disease. Children with PD catheters placed between February 2002 and July 2014 were retrospectively reviewed. Outcomes were catheter life, late (>30days post-op) complications (catheter malfunction, catheter malposition, infection), and re-operation rates. Comparison groups included laparoscopic versus open placement, age<2, and weight<10kg. Univariate and multivariate analysis were performed. One hundred sixteen patients had 173 catheters placed (122 open, 51 laparoscopic) with an average patient age of 9.7±6.3years. Mean catheter life was similar in the laparoscopic and open groups (581±539days versus 574±487days, p=0.938). The late complication rate was higher for open procedures (57% versus 37%, p=0.013). Children age<2 or weight<10kg had higher re-operation rates (64% versus 42%, p=0.014 and 73% versus 40%, p=0.001, respectively). Adjusted for age and weight, open technique remained a risk factor for late complications (OR 2.44, 95% CI 1.20-4.95) but not re-operation. Laparoscopic placement appears to reduce the rate of late complications in children who require PD dialysis catheters. Children <2years age or <10kg remain at risk for complications regardless of technique. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  19. Catheter-associated urinary tract infection.

    PubMed

    Tambyah, Paul A; Oon, Jolene

    2012-08-01

    Catheter-associated urinary tract infection (CAUTI) is the commonest nosocomial infection worldwide. Here we review the recent advances in the prevention of CAUTI. After more than 30 years, new guidelines were issued in 2008-2011 by the Infectious Diseases Society of America, Society for Healthcare Epidemiology of America, Healthcare Infection Control Practices Advisory Committee and European Association of Urology. These guidelines addressed novel technologies such as silver alloy or antimicrobial coatings on catheters, hydrophilic catheters, urethral stents, use of sealed catheter-tube junctions and antiinfective bladder irrigation. In addition, multiple trials have been published recently on the reduction of inappropriate urinary tract catheterization. Numerous strategies have been developed to reduce the incidence of CAUTI but few have proven effective. Reducing the inappropriate use of catheters and development of novel technologies targeted against these increasingly multidrug-resistant pathogens may be useful in the prevention of CAUTI in our vulnerable patients.

  20. Development of Bend Sensor for Catheter Tip

    NASA Astrophysics Data System (ADS)

    Nagano, Yoshitaka; Sano, Akihito; Fujimoto, Hideo

    Recently, a minimally invasive surgery which makes the best use of the catheter has been becoming more popular. In endovascular coil embolization for a cerebral aneurysm, the observation of the catheter's painting phenomenon is very important to execute the appropriate manipulation of the delivery wire and the catheter. In this study, the internal bend sensor which consists of at least two bending enhanced plastic optical fibers was developed in order to measure the curvature of the catheter tip. Consequently, the painting could be more sensitively detected in the neighborhood of the aneurysm. In this paper, the basic characteristics of the developed sensor system are described and its usefulness is confirmed from the comparison of the insertion force of delivery wire and the curvature of catheter tip in the experiment of coil embolization.

  1. Fourier plane imaging microscopy

    SciTech Connect

    Dominguez, Daniel, E-mail: daniel.dominguez@ttu.edu; Peralta, Luis Grave de; Nano Tech Center, Texas Tech University, Lubbock, Texas 79409

    We show how the image of an unresolved photonic crystal can be reconstructed using a single Fourier plane (FP) image obtained with a second camera that was added to a traditional compound microscope. We discuss how Fourier plane imaging microscopy is an application of a remarkable property of the obtained FP images: they contain more information about the photonic crystals than the images recorded by the camera commonly placed at the real plane of the microscope. We argue that the experimental results support the hypothesis that surface waves, contributing to enhanced resolution abilities, were optically excited in the studied photonicmore » crystals.« less

  2. Reconstruction of Abdominal Wall of a Chronically Infected Postoperative Wound with a Rectus Abdominis Myofascial Splitting Flap

    PubMed Central

    Bae, Sung Kyu; Kang, Seok Joo; Kim, Jin Woo; Kim, Young Hwan

    2013-01-01

    Background If a chronically infected abdominal wound develops, complications such as peritonitis and an abdominal wall defect could occur. This could prolong the patient's hospital stay and increase the possibility of re-operation or another infection as well. For this reason, a solution for infection control is necessary. In this study, surgery using a rectus abdominis muscle myofascial splitting flap was performed on an abdominal wall defect. Methods From 2009 to 2012, 5 patients who underwent surgery due to ovarian rupture, cesarean section, or uterine myoma were chosen. In each case, during the first week after operation, the wound showed signs of infection. Surgery was chosen because the wounds did not resolve with dressing. Debridement was performed along the previous operation wound and dissection of the skin was performed to separate the skin and subcutaneous tissue from the attenuated rectus muscle and Scarpa's fascial layers. Once the anterior rectus sheath and muscle were adequately mobilized, the fascia and muscle flap were advanced medially so that the skin defect could be covered for reconstruction. Results Upon 3-week follow-up after a rectus abdominis myofascial splitting flap operation, no major complication occurred. In addition, all of the patients showed satisfaction in terms of function and esthetics at 3 to 6 months post-surgery. Conclusions Using a rectus abdominis myofascial splitting flap has many esthetic and functional benefits over previous methods of abdominal defect treatment, and notably, it enabled infection control by reconstruction using muscle. PMID:23362477

  3. Surface electromyography activity of the rectus abdominis, internal oblique, and external oblique muscles during forced expiration in healthy adults.

    PubMed

    Ito, Kenichi; Nonaka, Koji; Ogaya, Shinya; Ogi, Atsushi; Matsunaka, Chiaki; Horie, Jun

    2016-06-01

    We aimed to characterize rectus abdominis, internal oblique, and external oblique muscle activity in healthy adults under expiratory resistance using surface electromyography. We randomly assigned 42 healthy adult subjects to 3 groups: 30%, 20%, and 10% maximal expiratory intraoral pressure (PEmax). After measuring 100% PEmax and muscle activity during 100% PEmax, the activity and maximum voluntary contraction of each muscle during the assigned experimental condition were measured. At 100% PEmax, the external oblique (p<0.01) and internal oblique (p<0.01) showed significantly elevated activity compared with the rectus abdominis muscle. Furthermore, at 20% and 30% PEmax, the external oblique (p<0.05 and<0.01, respectively) and the internal oblique (p<0.05 and<0.01, respectively) showed significantly elevated activity compared with the rectus abdominis muscle. At 10% PEmax, no significant differences were observed in muscle activity. Although we observed no significant difference between 10% and 20% PEmax, activity during 30% PEmax was significantly greater than during 20% PEmax (external oblique: p<0.05; internal oblique: p<0.01). The abdominal oblique muscles are the most active during forced expiration. Moreover, 30% PEmax is the minimum intensity required to achieve significant, albeit very slight, muscle activity during expiratory resistance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Embryo Transfer Catheters: Softer is Easier.

    PubMed

    Ruhlmann, Claudio; Gnocchi, Diego C; Cattaneo, Antonio R; Molina, Lucas G; Rivadeneira, Luciano Ruiz; Tessari, Lautaro; Martínez, Alejandro G

    2015-11-01

    This study aimed to compare the use of semi-rigid and flexible catheters in terms of pregnancy rate and level of difficulty of the embryo transfer (ET) procedure. Seven hundred and thirty-nine consecutive follicular aspirations for IVF or ICSI performed in our private fertility clinic within a 30-month period were randomly divided into two groups. Patients were allocated to either of the groups at the time of follicular retrieval with the aid of a random number generator according to the catheter used in ET: Group 1 (n = 370) - Frydman Classic Catheter 4.5 catheters; and Group 2 (n = 369) - Frydman Ultrasoft 4.5 catheters. Only patients offered ET in the randomized cycle were included (Group 1 = 363 and Group 2 = 340). Patients did not change groups after catheter allocation. Statistical analysis was carried out using an unpaired t-test or a chi square test as appropriate. Differences with P<0.05 were considered. A statistically significant difference in favor of the use of the Ultrasoft catheter was evident for parameters use of a tenaculum (19.8% vs. 5.9%) or a hysterometer (5.0% vs. 1.2%), presence of blood during post-ET inspection of the catheter (9.9% vs. 3.8%), and implantation rate (13.0% vs. 16.4%). Clinical pregnancy and delivery rates were comparable in both groups. Our results suggest that a softer catheter may help with difficult ETs. Softer catheters, as also reported by other authors, resulted in better implantation rates.

  5. 2. VIEW SOUTH, INCLINE PLANE CAR, INCLINE PLANE TRACK, UPPER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW SOUTH, INCLINE PLANE CAR, INCLINE PLANE TRACK, UPPER STATION. - Monongahela Incline Plane, Connecting North side of Grandview Avenue at Wyoming Street with West Carson Street near Smithfield Street, Pittsburgh, Allegheny County, PA

  6. [Venous catheter-related infections].

    PubMed

    Ferrer, Carmen; Almirante, Benito

    2014-02-01

    Venous catheter-related infections are a problem of particular importance, due to their frequency, morbidity and mortality, and because they are potentially preventable clinical processes. At present, the majority of hospitalized patients and a considerable number of outpatients are carriers of these devices. There has been a remarkable growth of knowledge of the epidemiology of these infections, the most appropriate methodology for diagnosis, the therapeutic and, in particular, the preventive strategies. Multimodal strategies, including educational programs directed at staff and a bundle of simple measures for implementation, applied to high-risk patients have demonstrated great effectiveness for their prevention. In this review the epidemiology, the diagnosis, and the therapeutic and preventive aspects of these infections are updated. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  7. ATLS: Catheter and tube placement

    NASA Technical Reports Server (NTRS)

    Gosbee, John; Krupa, Debra T.; Pepper, L.; Orsak, Debra

    1991-01-01

    The specific objectives of this experiment are: to evaluate the rack mounted equipment and medical supplies necessary for medical procedures; to evaluate the attachments, mounting points, and inner drawer assemblies for the medical supplies; and to evaluate the procedures for performing medical scenarios. The resources available in the HMF miniracks to accomplish medical scenarios and/or procedures include: medical equipment mounted in the racks; a patch panel with places to attach tubing and catheters; self contained drawers full of critical care medical supplies; and an ALS 'backpack' for deploying supplies. The attachment lines, tubing and associated medical supplies will be deployed and used with the equipment and a patient mannequin. Data collection is provided by direct observations by the inflight experimenters, and analysis of still and video photography.

  8. Specific fibre composition and metabolism of the rectus abdominis muscle of bovine Charolais cattle

    PubMed Central

    2010-01-01

    Background An important variability of contractile and metabolic properties between muscles has been highlighted. In the literature, the majority of studies on beef sensorial quality concerns M. longissimus thoracis. M. rectus abdominis (RA) is easy to sample without huge carcass depreciation and may appear as an alternative to M. longissimus thoracis for fast and routine physicochemical analysis. It was considered interesting to assess the muscle fibres of M. rectus abdominis in comparison with M. longissimus thoracis (LT) and M. triceps brachii (TB) on the basis of metabolic and contractile properties, area and myosin heavy chain isoforms (MyHC) proportions. Immuno-histochemical, histochemical, histological and enzymological techniques were used. This research concerned two populations of Charolais cattle: RA was compared to TB in a population of 19 steers while RA was compared to LT in a population of 153 heifers. Results RA muscle had higher mean fibre areas (3350 μm2 vs 2142 to 2639 μm2) than the two other muscles. In RA muscle, the slow-oxidative fibres were the largest (3957 μm2) and the fast-glycolytic the smallest (2868 μm2). The reverse was observed in TB muscle (1725 and 2436 μm2 respectively). In RA muscle, the distinction between fast-oxidative-glycolytic and fast-glycolytic fibres appeared difficult or impossible to establish, unlike in the other muscles. Consequently the classification based on ATPase and SDH activities seemed inappropriate, since the FOG fibres presented rather low SDH activity in this muscle in comparison to the other muscles of the carcass. RA muscle had a higher proportion of I fibres than TB and LT muscles, balanced by a lower proportion either of IIX fibres (in comparison to TB muscle) or of IIA fibres (in comparison to LT muscle). However, both oxidative and glycolytic enzyme activities were lower in RA than in TB muscle, although the LDH/ICDH ratio was higher in RA muscle (522 vs 340). Oxidative enzyme activities were

  9. Effect of age and carcass weight on quality traits of m. rectus abdominis from Charolais heifers.

    PubMed

    Ellies-Oury, M P; Dumont, R; Perrier, G; Roux, M; Micol, D; Picard, B

    2017-04-01

    In practice cattle may be slaughtered at different combinations of age and weight. As each of these factors could affect meat quality traits, the present work aimed to identify which combination can be expected to increase overall meat quality of m. rectus abdominis of Charolais heifers. Totally, 40 heifers were slaughtered either at 26±1 or at 36±1 months of age. Young heifers were sampled at two different carcass weights (349±12 and 394±8 kg). Old heifers were also sampled at two different carcass weights (397±6 and 451±9 kg). The m. rectus abdominis was excised 24 h postmortem to determine metabolic enzyme activities, myosin heavy-chain isoform proportions, lipid contents, collagen content and collagen solubility. Shear force measurements were evaluated on raw and broiled meat after 14 days of ageing. Meat quality traits scored between 0 and 10 by sensory analysis. Increasing slaughter age from 26 to 36 months had no impact on either raw/broiled shear force (0.31⩽P⩽0.47) and/or meat quality traits (0.62⩽P⩽0.91) or on physicochemical properties of heifer's meat samples. Increasing carcass weight for a similar slaughter age of 26 months had also impact neither on meat quality traits (0.52⩽P⩽0.91) nor on muscular properties. On the contrary, increasing carcass weight for a similar slaughter age of 36 months had induced a decrease of muscular shear force (raw muscle; P=0.009) and a concomitant decrease of total collagen content (P=0.03). Nevertheless, no significant impact on meat quality traits was revealed by the sensorial panel (0.13⩽P⩽0.49). Metabolic enzyme activities (0.13⩽P⩽0.86) and myosin heavy-chain proportions (0.13⩽P⩽0.96) were not significantly impacted by slaughter age and carcass weight. Thus, the impact of increasing carcass weight and/or slaughter age in young Charolais heifers has a limited impact on meat quality traits and associated muscular characteristics. Modulating heifer's cycles (age and/or carcass weight in

  10. Silicon sensors for catheters and guide wires

    NASA Astrophysics Data System (ADS)

    Goosen, Hans F.

    2001-11-01

    One area that can make use of the miniature size of present day micro electromechanical systems (MEMS) is that of the medical field of minimally invasive interventions. These procedures, used for both diagnosis and treatment, use catheters that are advanced through the blood vessels deep into the body, without the need for surgery. However, once inside the body, the doctor performing the procedure is completely reliant on the information the catheter(s) can provide in addition to the projection imaging of a fluoroscope. A good range of sensors for catheters is required for a proper diagnosis. To this end, miniature sensors are being developed to be fitted to catheters and guide wires. As the accurate positioning of these instruments is problematic, it is necessary to combine several sensors on the same guide wire or catheter to measure several parameters in the same location. This however, brings many special problems to the design of the sensors, such as small size, low power consumption, bio-compatibility of materials, robust design for patient safety, a limited number of connections, packaging, etc. This paper will go into both the advantages and design problems of micromachined sensors and actuators in catheters and guide wires. As an example, a multi parameter blood sensor, measuring flow velocity, pressure and oxygen saturation, will be discussed.

  11. Avoiding Complications in Abdominal Wall Surgery: A Mathematical Model to Predict the Course of the Motor Innervation of the Rectus Abdominis.

    PubMed

    Tessone, Ariel; Nava, Maurizio; Blondeel, Phillip; Spano, Andrea

    2016-02-01

    Ever since its introduction, the transverse rectus abdominis myocutaneous flap has become the mainstay of autologous breast reconstruction. However, concerns regarding donor site morbidity due to the breach of abdominal wall musculature integrity soon followed. Muscle-sparing techniques, eventually eliminating the muscle from the flap all-together with the deep inferior epigastric artery perforator flap, did not eliminate the problem of abdominal wall weakness. This led to the conclusion that motor innervation might be at fault. Studies have shown that even in the presence of an intact rectus abdominis muscle, and an intact anterior rectus sheath, denervation of the rectus abdominis muscle results in significant abdominal wall weakness leading to superior and inferior abdominal bulges, and abdominal herniation. Our aim was to establish a mathematical model to predict the location of the motor innervation to the rectus abdominis muscle, and thus provide surgeons with a tool that will allow them to reduce abdominal morbidity during deep inferior epigastric artery perforator and free muscle-sparing transverse rectus abdominis myocutaneous surgery. We dissected 42 cadaveric hemiabdomens and mapped the course of the thoracolumbar nerves. We then standardized and analyzed our findings and presented them as a relative map which can be adjusted to body type and dimensions. Our dissections show that the motor innervation is closely related to the lateral vascular supply. Thus, when possible, we support the preferred utilization of the medial vascular supply, and the preservation of the lateral supply and motor innervation.

  12. Mechanical Evaluation of Unobstructing Magnetic Microactuators for Implantable Ventricular Catheters

    PubMed Central

    Lee, Hyowon; Kolahi, Kameran; Bergsneider, Marvin; Judy, Jack W.

    2017-01-01

    Here, we report on the development and evaluation of novel unobstructing magnetic microactuators for maintaining the patency of implantable ventricular catheters used in hydrocephalus application. The treatment of hydrocephalus requires chronic implantation of a shunt system to divert excess cerebrospinal fluid from the brain. These shunt systems suffer from a high failure rate (>40%) within the first year of implantation, often due to biological accumulation. Previously, we have shown that magnetic microactuators can be used to remove biological blockage. The new cantilever-based magnetic microactuator presented in this paper improves upon the previous torsional design using a bimorph to induce a postrelease out-of-plane deflection that will prevent the device from occluding the pore at rest. The mechanical evaluations (i.e., postrelease deflection, static and dynamic responses) of fabricated devices are reported and compared with theoretical values. PMID:29151776

  13. Catheter orifice configuration influences the effectiveness of continuous peripheral nerve blockade.

    PubMed

    Fredrickson, Michael J; Ball, Craig M; Dalgleish, Adam J

    2011-01-01

    We investigated perineural catheter threading distance and orifice configuration during continuous interscalene analgesia. One hundred fifty-three patients receiving an anterolateral interscalene catheter (catheter needle and nerve/plexus in a similar alignment) for elective shoulder surgery were randomized to 1 of 3 groups: following out-of-plane ultrasound confirmation of the needle tip immediately lateral to the C5/6 roots, a nonstimulating catheter was blindly advanced 0.5 cm (end-hole; n = 50), 2.5 cm (multiorifice; n = 50) or 5 cm (multiorifice; n = 53) beyond the needle tip. Ropivacaine 0.75% + lidocaine 1% (50:50) 20 mL was administered preoperatively via the catheter before surgery under general anesthesia. A ropivacaine 0.2% 2 mL/hr elastomeric infusion with mandatory 6 hourly (and on demand) 5-mL boluses was continued for more than 48 hrs with tramadol available as rescue. Patients were questioned in the recovery room, at 24 and 48 hrs for numerical rating pain score (0-10), ropivacaine bolus, and tramadol consumption. Patients were more frequently pain-free in the recovery room in the multiorifice 2.5 and 5 cm groups compared with the end-hole 0.5 cm group (94%, 91% vs 66%; P < 0.001). During the first 24 hrs, the end-hole group demonstrated an earlier time to first pain (median, 10 vs17, 15 hrs; P < 0.001), higher "average pain" (median, 3 vs 1, 2, P = 0.004), and more ropivacaine bolus (median, 5 vs 3, 3; P < 0.001) and tramadol consumption (P = 0.01). Groups 2.5 and 5 cm did not significantly differ in any outcomes. These results suggest that multiorifice catheters provide superior intermittent bolus continuous peripheral nerve blockade compared with end-hole catheters. For anterolateral approach interscalene catheter placement, there is minimal benefit, either way, to 2.5- or 5-cm blind catheter advancement.

  14. Reliability of real-time ultrasound for the assessment of transversus abdominis function.

    PubMed

    Kidd, Adrian W; Magee, Scott; Richardson, Carolyn A

    2002-07-01

    Transversus abdominis (TrA) has now been established as a key muscle for the stabilization of the lumbar spine and sacroiliac joints. Significantly, dysfunction of this muscle has also been implicated in low back pain. Real-time ultrasound (US) is a non-invasive procedure that has the potential to evaluate objectively the function of TrA. To investigate M-mode US as a reliable method of assessing TrA function. M-mode US was used to measure the width of TrA as subjects drew in their lower abdominal wall at a controlled speed to a target depth. Eleven subjects were imaged. the measures of TrA width were reliable and ranged between 3.14mm relaxed and 6.35mm contracted. The standard error of measurement ranged between 0.18mm and 0.57mm. M-mode US provides a reliable non-invasive measure of a controlled contraction of TrA.

  15. Transversus abdominis is part of a global not local muscle synergy during arm movement.

    PubMed

    Morris, S L; Lay, B; Allison, G T

    2013-10-01

    The trunk muscle transversus abdominis (TrA) is thought to be controlled independently of the global trunk muscles. Methodological issues in the 1990s research such as unilateral electromyography and a limited range of arm movements justify a re-examination of this theory. The hypothesis tested is that TrA bilateral co-contraction is a typical muscle synergy during arm movement. The activity of 6 pairs of trunk and lower limb muscles was recorded using bilateral electromyography during anticipatory postural adjustments (APAs) associated with the arm movements. The integrated APA electromyographical signals were analyzed for muscle synergy using Principle Component Analysis. TrA does not typically bilaterally co-contract during arm movements (1 out of 6 participants did). APA muscle activity of all muscles during asymmetrical arm movements typically reflected a direction specific diagonal pattern incorporating a twisting motion to transfer energy from the ground up. This finding is not consistent with the hypothesis that TrA plays a unique role providing bilateral, feedforward, multidirectional stiffening of the spine. This has significant implications to the theories underlying the role of TrA in back pain and in the training of isolated bilateral co-contraction of TrA in the prophylaxis of back pain. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  16. Treatment of elbow osteomyelitis with an interposition arthroplasty using a rectus abdominis free flap.

    PubMed

    Jaiswal, Rohit; Busse, Brittany; Allen, Robert; Sahar, David

    2015-05-01

    Osteomyelitis of the elbow may be a complex clinical problem. Treatment goals include the eradication of infection and preservation of maximal joint function. Bony debridement may be necessary in addition to elbow joint arthroplasty. The use of synthetic material or allograft as the arthroplasty material may be contraindicated in the setting of infection. The use of free muscle transfer as an arthroplasty medium has not been well described. A 22-year-old paraplegic man developed recurrent osteomyelitis of the right elbow, necessitating extensive bony debridement by the orthopedic surgery team. Reconstruction arthroplasty was performed using a free rectus abdominis muscle flap as the arthroplasty material to serve as a source of biologically active, well-vascularized arthroplasty medium in the presence of ongoing infection. A successful free muscle flap arthroplasty was performed. External fixation and physical therapy were implemented postoperatively. The patient had resolution of osteomyelitis and excellent functional use of the elbow for activities of daily living and wheelchair motion. Elbow arthroplasty in the setting of active infection may be accomplished by means of free tissue muscle transfer. Elimination of infection and acceptable joint function may be possible with this form of reconstruction.

  17. PRE-INOCULATION OF URINARY CATHETERS WITH ESCHERICHIA COLI 83972 INHIBITS CATHETER COLONIZATION BY ENTEROCOCCUS FAECALIS

    PubMed Central

    TRAUTNER, BARBARA W.; DAROUICHE, RABIH O.; HULL, RICHARD A.; HULL, SHEILA; THORNBY, JOHN I.

    2010-01-01

    Purpose The capacity of a preexisting coating of Escherichia coli 83972 to reduce catheter colonization by Enterococcus faecalis 210 was investigated. Enterococcus was chosen for these trials since it is a common urinary pathogen in patients with an indwelling urinary catheter. Materials and Methods Each experiment tested 3 growth conditions. Group 1 or E. coli plus Enterococcus catheters were exposed to E. coli 83972 for 24 hours and then to Enterococcus for 30 minutes. Group 2 or E. coli alone catheters were incubated in E. coli for 24 hours and then in sterile broth for 30 minutes. Group 3 or Enterococcus alone catheters did not undergo the initial incubation with E. coli before the 30-minute incubation with Enterococcus: All catheters were then incubated in sterile human urine for 24 hours. Catheters were washed with saline and cut into 5, 1 cm. segments. Each segment was sonicated and the sonication fluid was diluted and plated. The results of each of the 5 segments were averaged and the set of experiments was repeated 7 times. Results A preexisting coating of E. coli 83972 reduced catheter colonization by E. faecalis 210 more than 10-fold. Enterococcus alone catheters had a median of 9.7 × 105 enterococci per cm., whereas E. coli plus Enterococcus catheters had a median of 0.38 × 105 enterococci per cm. (p = 0.016). Conclusions Pre-inoculating urinary catheters with E. coli 83972 significantly impedes catheter colonization by Enterococcus: These promising in vitro results prompt the clinical investigation of this particular application of bacterial interference. PMID:11743359

  18. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections.

    PubMed

    Lorente, Leonardo

    2016-05-04

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it.

  19. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections

    PubMed Central

    Lorente, Leonardo

    2016-01-01

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it. PMID:27152256

  20. [Peripheral intravenous catheter-related phlebitis].

    PubMed

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  1. 21 CFR 882.4100 - Ventricular catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Identification. A ventricular catheter is a device used to gain access to the cavities of the brain for injection of material into, or removal of material from, the brain. (b) Classification. Class II (performance...

  2. 21 CFR 882.4100 - Ventricular catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Identification. A ventricular catheter is a device used to gain access to the cavities of the brain for injection of material into, or removal of material from, the brain. (b) Classification. Class II (performance...

  3. 21 CFR 882.4100 - Ventricular catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Identification. A ventricular catheter is a device used to gain access to the cavities of the brain for injection of material into, or removal of material from, the brain. (b) Classification. Class II (performance...

  4. 21 CFR 882.4100 - Ventricular catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Identification. A ventricular catheter is a device used to gain access to the cavities of the brain for injection of material into, or removal of material from, the brain. (b) Classification. Class II (performance...

  5. 21 CFR 882.4100 - Ventricular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identification. A ventricular catheter is a device used to gain access to the cavities of the brain for injection of material into, or removal of material from, the brain. (b) Classification. Class II (performance...

  6. Advanced Imaging Catheter: Final Project Report

    SciTech Connect

    Krulevitch, P; Colston, B; DaSilva, L

    2001-07-20

    Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area.more » The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body

  7. Emergency catheter ablation in critical patients

    PubMed Central

    Tebbenjohanns, Jürgen; Rühmkorf, Klaus

    2010-01-01

    Emergency catheter ablation is justified in critical patients with drug-refractory life-threatening arrhythmias. The procedure can be used for ablation of an accessory pathway in preexcitation syndrome with high risk of ventricular fibrillation and in patients with shock due to ischemic cardiomyopathy and incessant ventricular tachycardia. Emergency catheter ablation can also be justified in patients with an electrical storm of the implanted cardioverter-defibrillator or in patients with idiopathic ventricular fibrillation. PMID:20606793

  8. Pacing threshold changes after transvenous catheter countershock.

    PubMed

    Yee, R; Jones, D L; Klein, G J

    1984-02-01

    The serial changes in pacing threshold and R-wave amplitude were examined after insertion of a countershock catheter in 12 patients referred for management of recurrent ventricular tachyarrhythmias. In 6 patients, values before and immediately after catheter countershock were monitored. Pacing threshold increased (from 1.4 +/- 0.2 to 2.4 +/- 0.5 V, mean +/- standard error of the mean, p less than 0.05) while the R-wave amplitude decreased (bipolar R wave from 5.9 +/- 1.1 to 3.4 +/- 0.7 mV, p less than 0.01; unipolar R wave recorded from the distal ventricular electrode from 8.9 +/- 1.8 to 4.6 +/- 1.2 mV, p less than 0.01; and proximal ventricular electrode from 7.7 +/- 1.5 to 5.0 +/- 1.0 mV, p less than 0.01). A return to control values occurred within 10 minutes. In all patients, pacing threshold increased by 154 +/- 30% (p less than 0.001) during the first 7 days that the catheter was in place. It is concluded that catheter countershock causes an acute increase in pacing threshold and decrease in R-wave amplitude. A catheter used for countershock may not be acceptable as a backup pacing catheter.

  9. [Hodge and his planes].

    PubMed

    van Gijn, Jan; Gijselhart, Joost P

    2010-01-01

    Hugh Lenox Hodge (1796-1873) was professor of obstetrics at the University of Pennsylvania for more than 25 years. He divided the birth canal into four virtual and parallel planes through pelvic protuberances, a method still widely used. He also developed a pessary that is now mainly used in stress incontinence.

  10. Plane Jane(s).

    ERIC Educational Resources Information Center

    Greenman, Geri

    2001-01-01

    Describes an assignment that was used in an advanced drawing class in which the students created self-portraits, breaking up their images using planes and angles to suggest their bone structure. Explains that the students also had to include three realistic portions in their drawings. (CMK)

  11. Internal Oblique and Transversus Abdominis Muscle Fatigue Induced by Slumped Sitting Posture after 1 Hour of Sitting in Office Workers

    PubMed Central

    Waongenngarm, Pooriput; Rajaratnam, Bala S.; Janwantanakul, Prawit

    2015-01-01

    Background Prolonged sitting leads to low back discomfort and lumbopelvic muscle fatigue. This study examined the characteristics of body perceived discomfort and trunk muscle fatigue during 1 hour of sitting in three postures in office workers. Methods Thirty workers sat for 1 hour in one of three sitting postures (i.e., upright, slumped, and forward leaning postures). Body discomfort was assessed using the Body Perceived Discomfort scale at the beginning and after 1 hour of sitting. Electromyographic (EMG) signals were recorded from superficial lumbar multifidus, iliocostalis lumborum pars thoracis, internal oblique (IO)/transversus abdominis (TrA), and rectus abdominis muscles during 1 hour of sitting. The median frequency (MDF) of the EMG power spectrum was calculated. Results Regardless of the sitting posture, the Body Perceived Discomfort scores in the neck, shoulder, upper back, low back, and buttock significantly increased after 1 hour of sitting compared with baseline values (t(9) = −11.97 to −2.69, p < 0.05). The MDF value of the EMG signal of rectus abdominis, iliocostalis lumborum pars thoracis, and multifidus muscles was unchanged over time in all three sitting postures. Only the right and left IO/TrA in the slumped sitting posture was significantly associated with decreased MDF over time (p = 0.019 to 0.041). Conclusion Prolonged sitting led to increased body discomfort in the neck, shoulder, upper back, low back, and buttock. No sign of trunk muscle fatigue was detected over 1 hour of sitting in the upright and forward leaning postures. Prolonged slumped sitting may relate to IO/TrA muscle fatigue, which may compromise the stability of the spine, making it susceptible to injury. PMID:27014491

  12. Analysis of fiber type transformation and histology in chronic electrically stimulated canine rectus abdominis muscle island-flap stomal sphincters.

    PubMed

    Majzoub, Ramsey K; Bardoel, Janou W J M; Maldonado, Claudio; Barker, John H; Stadelmann, Wayne K

    2003-01-01

    Dynamic skeletal muscle flaps are designed to perform a specific functional task through contraction and relaxation of their muscle fibers. The most commonly used dynamic skeletal flaps today are for cardiomyoplasty and anal or urinary myoplasty. Low-frequency chronic stimulation of these flaps enables them to use their intrinsic energy stores in a more efficient manner through aerobic metabolic pathways for increased endurance and improved work capacity. The purpose of this study was to (1) determine whether fiber type transformation from fatigue-prone (type II) muscle fibers to fatigue-resistant (type I) muscle fibers could be demonstrated in the authors' chronic canine stomal sphincter model where the rectus abdominis muscle was used to create a functional stomal sphincter, (2) assess whether there is any correlation between the degree of muscle fiber type transformation and the continence times, and (3) examine the long-term effects of the training regimens on the skeletal muscle fibers through histologic and volumetric analysis. Eight dynamic island-flap sphincters were created from a part of the rectus abdominis muscle in mongrel dogs by preserving the deep inferior epigastric vascular pedicle and the most caudal investing intercostal nerve. The muscular sphincters were wrapped around a blind loop of distal ileum and trained with pacing electrodes. Two different training protocols were used. In group A (n = 4), a preexisting anal dynamic graciloplasty training protocol was used. A revised protocol was used in group B (n = 4). Muscle biopsy specimens were obtained before and after training from the rectus abdominis muscle sphincter. Fiber type transformation was assessed using a monoclonal antibody directed against the fatigue-prone type II fibers. Pretraining and posttraining skeletal muscle specimens were examined histologically. A significant fiber type conversion was achieved in both group A and group B animals, with each group achieving greater than 50

  13. Minilaparotomy salvage of malfunctioning catheters in peritoneal dialysis.

    PubMed

    Li, Jian-Ri; Cheng, Chi-Hung; Chiu, Kun-Yuan; Cheng, Chen-Li; Yang, Chi-Rei; Ho, Hao-Chung; Ko, Jiunn-Liang; Ou, Yen-Chuan

    2013-01-01

    Catheter malfunction is a common and significant complication during peritoneal dialysis (PD). We developed a minilaparotomy procedure to rescue malfunctioning catheters and to prevent recurrence of malfunction. From 2006 to 2011, 11 patients receiving PD had a malfunctioning catheter. In all patients, a 2-cm incision, 5 cm caudally to the previous peritoneal entry site was used to correct the malfunctioning catheter, with concomitant fixation of the catheter to the peritoneum. Catheter tip migration occurred in 7 patients, omental wrapping in 3, and blood clot obstruction in 1. The mean onset time to catheter malfunction was 197.5 days (range: 4 - 1270 days), and the mean operating time was 41 minutes (range: 35 - 56 minutes). There was no recurrence of catheter malfunction and no surgery-related peritonitis. Our minilaparotomy procedure is safe and feasible for the salvage of malfunctioning PD catheters.

  14. Impaired mitochondrial oxidative phosphorylation and supercomplex assembly in rectus abdominis muscle of diabetic obese individuals.

    PubMed

    Antoun, Ghadi; McMurray, Fiona; Thrush, A Brianne; Patten, David A; Peixoto, Alyssa C; Slack, Ruth S; McPherson, Ruth; Dent, Robert; Harper, Mary-Ellen

    2015-12-01

    Skeletal muscle mitochondrial dysfunction has been documented in patients with type 2 diabetes mellitus; however, specific respiratory defects and their mechanisms are poorly understood. The aim of the current study was to examine oxidative phosphorylation and electron transport chain (ETC) supercomplex assembly in rectus abdominis muscles of 10 obese diabetic and 10 obese non-diabetic individuals. Twenty obese women undergoing Roux-en-Y gastric bypass surgery were recruited for this study. Muscle samples were obtained intraoperatively and subdivided for multiple analyses, including high-resolution respirometry and assessment of supercomplex assembly. Clinical data obtained from referring physicians were correlated with laboratory findings. Participants in both groups were of a similar age, weight and BMI. Mitochondrial respiration rates were markedly reduced in diabetic vs non-diabetic patients. This defect was observed during maximal ADP-stimulated respiration in the presence of complex I-linked substrates and complex I- and II-linked substrates, and during maximal uncoupled respiration. There were no differences in fatty acid (octanoyl carnitine) supported respiration, leak respiration or isolated activity of cytochrome c oxidase. Intriguingly, significant correlations were found between glycated haemoglobin (HbA1c) levels and maximal respiration or respiration supported by complex I, complex I and II or fatty acid. In the muscle of diabetic patients, blue native gel electrophoresis revealed a striking decrease in complex I, III and IV containing ETC supercomplexes. These findings support the hypothesis that ETC supercomplex assembly may be an important underlying mechanism of muscle mitochondrial dysfunction in type 2 diabetes mellitus.

  15. Reliability of real-time ultrasound measurement of transversus abdominis thickness in healthy trained subjects.

    PubMed

    Gnat, Rafael; Saulicz, Edward; Miądowicz, Barbara

    2012-08-01

    To investigate intra- and inter-rater reliability of the ultrasound measurement of transversus abdominis (TrA) thickness and thickness change (difference between thickness at rest and during contraction) in asymptomatic, trained subjects. To define the number of repeated measurements that provide acceptable level of reliability. To investigate variability of the measurements over time of 5 days and the reliability of duplicate analysis of images. A single-group repeated-measures design was used to assess reliability. Healthy volunteers (n = 10) were subjected to 1-week training in voluntary activation of TrA. Real-time ultrasound imaging and subsequent measurement of the TrA thickness at rest and during voluntary contraction were repeated on Monday, Wednesday and Friday of the next week. Using a single repeated measurement, intraclass correlation coefficients (ICCs) for TrA thickness were: 0.86-0.95 (intra-rater), 0.86-0.92 (inter-rater); and for TrA thickness change: 0.34-0.56 (intra-rater), 0.47-0.61 (inter-rater). Using the mean of three repeated measurements respective values were: 0.97, 0.96-0.98; and 0.81-0.84, 0.80-0.90. No significant differences were found between mean values of TrA thickness as well as thickness change obtained on three consecutive measurement days. Duplicate analysis of the images was highly reliable with ICCs of 0.89-0.99. Two repeated measurements for TrA thickness and at least three measurements for TrA thickness change are needed to achieve acceptable levels of intra- and inter-rater reliability. In healthy trained volunteers TrA thickness and thickness change are relatively stable parameters over a 5-day period. Duplicate analysis of the same images by two blinded observers is reliable.

  16. Supercharging the transverse rectus abdominis musculocutaneous flap: breast reconstruction for the overweight and obese population.

    PubMed

    Wu, Liza C; Iteld, Lawrence; Song, David H

    2008-06-01

    Autologous breast reconstruction with the transverse rectus abdominis musculocutaneous (TRAM) flap is traditionally based on either the superior epigastric vessels (pedicled) or the deep inferior system (free). In the overweight and obese population, both techniques have been shown to have increased complications of the reconstructed breast. Another alternative is supercharging the flap by anastamosing the deep inferior epigastric vessels to either the internal mammary or thoracodorsal systems. We present a single surgeon's experience with unilateral TRAM reconstructions supercharged to either the thoracodorsal vessels, the internal mammary system, or in one case, perforator vessels in overweight and obese patients. Nineteen consecutive overweight or obese patients underwent delayed or immediate, unilateral autologous breast reconstruction with supercharged TRAM flaps between November 2000 and November 2004. The patients ranged in age from 28 to 66 years (average 49) and had an average body mass index (BMI) of 29.5 (24.9-38.3). Twelve patients had a BMI between 25 and 29.9 kg/m2; 7 patients had BMI > or =30 kg/m2. Left-sided reconstructions were 13; right-sided reconstructions were 6. Supercharging was performed by anastamosing the deep inferior epigastric artery and vein to the thoracodorsal vessels, internal mammary vessels, or perforator vessels. Follow-up ranged from 6 to 54 months. There was a qualitative increase in blood flow measured by audible Doppler signals in all patients after the arterial and venous anastamoses. There were no cases of partial or complete flap loss. One patient had a hematoma and subsequently developed minor fat necrosis. One patient had an infection of the reconstructed breast. There were no donor site complications. Supercharging the TRAM flap by means of microvascular augmentation of the deep inferior epigastric vessels provides a safe and effective breast reconstruction in the overweight and obese population with no additional

  17. Simultaneous orthogonal plane imaging.

    PubMed

    Mickevicius, Nikolai J; Paulson, Eric S

    2017-11-01

    Intrafraction motion can result in a smearing of planned external beam radiation therapy dose distributions, resulting in an uncertainty in dose actually deposited in tissue. The purpose of this paper is to present a pulse sequence that is capable of imaging a moving target at a high frame rate in two orthogonal planes simultaneously for MR-guided radiotherapy. By balancing the zero gradient moment on all axes, slices in two orthogonal planes may be spatially encoded simultaneously. The orthogonal slice groups may be acquired with equal or nonequal echo times. A Cartesian spoiled gradient echo simultaneous orthogonal plane imaging (SOPI) sequence was tested in phantom and in vivo. Multiplexed SOPI acquisitions were performed in which two parallel slices were imaged along two orthogonal axes simultaneously. An autocalibrating phase-constrained 2D-SENSE-GRAPPA (generalized autocalibrating partially parallel acquisition) algorithm was implemented to reconstruct the multiplexed data. SOPI images without intraslice motion artifacts were reconstructed at a maximum frame rate of 8.16 Hz. The 2D-SENSE-GRAPPA reconstruction separated the parallel slices aliased along each orthogonal axis. The high spatiotemporal resolution provided by SOPI has the potential to be beneficial for intrafraction motion management during MR-guided radiation therapy or other MRI-guided interventions. Magn Reson Med 78:1700-1710, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Central venous catheter-associated bloodstream infections in a pediatric intensive care unit: effect of the location of catheter insertion.

    PubMed

    Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan

    2012-05-01

    To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.

  19. Left Atrial Anatomy Relevant to Catheter Ablation

    PubMed Central

    Sánchez-Quintana, Damián; Cabrera, José Angel; Saremi, Farhood

    2014-01-01

    The rapid development of interventional procedures for the treatment of arrhythmias in humans, especially the use of catheter ablation techniques, has renewed interest in cardiac anatomy. Although the substrates of atrial fibrillation (AF), its initiation and maintenance, remain to be fully elucidated, catheter ablation in the left atrium (LA) has become a common therapeutic option for patients with this arrhythmia. Using ablation catheters, various isolation lines and focal targets are created, the majority of which are based on gross anatomical, electroanatomical, and myoarchitectual patterns of the left atrial wall. Our aim was therefore to review the gross morphological and architectural features of the LA and their relations to extracardiac structures. The latter have also become relevant because extracardiac complications of AF ablation can occur, due to injuries to the phrenic and vagal plexus nerves, adjacent coronary arteries, or the esophageal wall causing devastating consequences. PMID:25057427

  20. Catheter tip force transducer for cardiovascular research

    NASA Technical Reports Server (NTRS)

    Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H. (Inventor)

    1976-01-01

    A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter.

  1. The importance of effective catheter securement.

    PubMed

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  2. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    PubMed

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  3. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    PubMed

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  4. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  5. The Three Planes of Language.

    ERIC Educational Resources Information Center

    Sampson, Gloria

    1999-01-01

    Currently, the language sciences place together four different forms of mental activity on one plane of language, which results in confusion. This paper presents arguments from metaphysics, hermeneutics, and semiotics to demonstrate that there are actually three planes of language (a biologically-based information processing plane, a literal…

  6. Comparative analysis of open and robotic transversus abdominis release for ventral hernia repair.

    PubMed

    Bittner, James G; Alrefai, Sameer; Vy, Michelle; Mabe, Micah; Del Prado, Paul A R; Clingempeel, Natasha L

    2018-02-01

    Transversus abdominis release (TAR) is a safe, effective strategy to repair complex ventral incisional hernia (VIH); however, open TAR (o-TAR) often necessitates prolonged hospitalization. Robot-assisted TAR (r-TAR) may benefit short-term outcomes and shorten convalescence. This study compares 90-day outcomes of o-TAR and r-TAR for VIH repair. A single-center, retrospective review of patients who underwent o-TAR or r-TAR for VIH from 2015 to 2016 was conducted. Patient and hernia characteristics, operative data, and 90-day outcomes were compared. The primary outcome was hospital length of stay, and secondary metrics were morbidity, surgical site events, and readmission. Overall, 102 patients were identified (76 o-TAR and 26 r-TAR). Patients were comparable regarding age, gender, body mass index, and the presence of co-morbidities. Diabetes was more common in the open group (22.3 vs. 0%, P = 0.01). Most VIH defects were midline (89.5 vs. 83%, P = 0.47) and recurrent (52.6 vs. 58.3%, P = 0.65). Hernia characteristics were similar regarding mean defect size (260 ± 209 vs. 235 ± 107 cm 2 , P = 0.55), mesh removal, and type/size mesh implanted. Average operative time was longer in the r-TAR cohort (287 ± 121 vs. 365 ± 78 min, P < 0.01) despite most receiving mesh fixation with fibrin sealant alone (18.4 vs. 91.7%, P < 0.01). r-TAR trended toward lower morbidity (39.2 vs. 19.2%, P = 0.09), less severe complications, and similar rates of surgical site events and readmission (6.6 vs. 7.7%, P = 1.00). In addition, r-TAR resulted in a significantly shorter median hospital length of stay compared to o-TAR (6 days, 95% CI 5.9-8.3 vs. 3 days, 95% CI 3.2-4.3). In select patients, the robotic surgical platform facilitates a safe, minimally invasive approach to complex abdominal wall reconstruction, specifically TAR. Robot-assisted TAR for VIH offers the short-term benefits of low morbidity and decreased hospital length of stay compared to open TAR.

  7. The Aerodynamic Plane Table

    NASA Technical Reports Server (NTRS)

    Zahm, A F

    1924-01-01

    This report gives the description and the use of a specially designed aerodynamic plane table. For the accurate and expeditious geometrical measurement of models in an aerodynamic laboratory, and for miscellaneous truing operations, there is frequent need for a specially equipped plan table. For example, one may have to measure truly to 0.001 inch the offsets of an airfoil at many parts of its surface. Or the offsets of a strut, airship hull, or other carefully formed figure may require exact calipering. Again, a complete airplane model may have to be adjusted for correct incidence at all parts of its surfaces or verified in those parts for conformance to specifications. Such work, if but occasional, may be done on a planing or milling machine; but if frequent, justifies the provision of a special table. For this reason it was found desirable in 1918 to make the table described in this report and to equip it with such gauges and measures as the work should require.

  8. Fourier plane image amplifier

    DOEpatents

    Hackel, Lloyd A.; Hermann, Mark R.; Dane, C. Brent; Tiszauer, Detlev H.

    1995-01-01

    A solid state laser is frequency tripled to 0.3 .mu.m. A small portion of the laser is split off and generates a Stokes seed in a low power oscillator. The low power output passes through a mask with the appropriate hole pattern. Meanwhile, the bulk of the laser output is focused into a larger stimulated Brillouin scattering (SBS) amplifier. The low power beam is directed through the same cell in the opposite direction. The majority of the amplification takes place at the focus which is the fourier transform plane of the mask image. The small holes occupy large area at the focus and thus are preferentially amplified. The amplified output is now imaged onto the multichip module where the holes are drilled. Because of the fourier plane amplifier, only .about.1/10th the power of a competitive system is needed. This concept allows less expensive masks to be used in the process and requires much less laser power.

  9. Fourier plane image amplifier

    DOEpatents

    Hackel, L.A.; Hermann, M.R.; Dane, C.B.; Tiszauer, D.H.

    1995-12-12

    A solid state laser is frequency tripled to 0.3 {micro}m. A small portion of the laser is split off and generates a Stokes seed in a low power oscillator. The low power output passes through a mask with the appropriate hole pattern. Meanwhile, the bulk of the laser output is focused into a larger stimulated Brillouin scattering (SBS) amplifier. The low power beam is directed through the same cell in the opposite direction. The majority of the amplification takes place at the focus which is the fourier transform plane of the mask image. The small holes occupy large area at the focus and thus are preferentially amplified. The amplified output is now imaged onto the multichip module where the holes are drilled. Because of the fourier plane amplifier, only about 1/10th the power of a competitive system is needed. This concept allows less expensive masks to be used in the process and requires much less laser power. 1 fig.

  10. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    PubMed

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  11. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  12. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  13. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  14. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  15. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  16. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  17. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  18. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  19. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  20. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  1. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  2. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  3. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  4. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  5. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  6. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  7. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  8. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  9. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  10. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  11. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    PubMed

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Thoracoscopic retrieval of a fractured thoracentesis catheter.

    PubMed

    Albrink, M H; McAllister, E W

    1994-08-01

    With the resurgence of laparoscopic surgical procedures, thorascopic procedures have followed close behind. Many procedures which in the past have required formal thoracotomy may now be performed via less invasive methods. Presented herein is a report and description of thoracoscopic retrieval of a fractured thoracentesis catheter.

  13. Lymphatic Leak Complicating Central Venous Catheter Insertion

    SciTech Connect

    Barnacle, Alex M., E-mail: alexbarnacle@yahoo.co.uk; Kleidon, Tricia M.

    2005-12-15

    Many of the risks associated with central venous access are well recognized. We report a case of inadvertent lymphatic disruption during the insertion of a tunneled central venous catheter in a patient with raised left and right atrial pressures and severe pulmonary hypertension, which led to significant hemodynamic instability. To our knowledge, this rare complication is previously unreported.

  14. Prophylactic teicoplanin during insertion of Hickman catheters.

    PubMed

    Lim, S H; Smith, M P; Machin, S J; Goldstone, A H

    1990-12-01

    With the extensive use of Hickman catheters in patients requiring cytotoxic chemotherapy there is now a resurgence of Gram-positive septicaemia among these patients during the neutropenic periods. We are currently running a prospective randomized study of prophylactic teicoplanin during insertion of Hickman catheters to determine if it reduces the incidence of Gram-positive septicaemia. A total of 44 patients have completed the study (23 in the teicoplanin group and 21 in the control group). The diagnoses were: acute myelogenous leukaemia (13), non-Hodgkin's lymphoma (16), Hodgkin's disease (11), chronic granulocytic leukaemia (3) and acute lymphoblastic leukaemia (1). The number of days between insertion of Hickman catheters and the development of neutropenia was: teicoplanin group: mean 14.7, median 11, range 0-53; control group: mean 11.8, median 10, range 0-37. In the treated patients, there were four episodes of line-associated Gram-positive septicaemia and a total of four organisms were isolated. In the control group, 10 organisms were isolated from a total of nine episodes of line-associated Gram-positive septicaemia. The organisms were: coagulase-negative staphylococci (8), Streptococcus B, (1), Strep. faecalis (1), Strep. mitis (1), alpha streptococcus (1), diphtheriods (1) and Staphylococcus aureus (1). All organisms were sensitive to teicoplanin. No adverse reaction was observed in any patient. Prophylactic teicoplanin during insertion of Hickman catheters may therefore reduce the incidence of line-associated Gram-positive septicaemia in neutropenic patients.

  15. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intravascular catheter. 880.5200 Section 880.5200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic...

  16. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intravascular catheter. 880.5200 Section 880.5200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic...

  17. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intravascular catheter. 880.5200 Section 880.5200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic...

  18. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intravascular catheter. 880.5200 Section 880.5200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic...

  19. Bacterial contamination of epidural catheters: microbiological examination of 502 epidural catheters used for postoperative analgesia.

    PubMed

    Steffen, Peter; Seeling, Wulf; Essig, Andreas; Stiepan, Erika; Rockemann, Michael Georg

    2004-03-01

    To investigate the frequency of bacterial colonization of epidural catheters used for postoperative pain treatment longer than 24 hours in abdominal, thoracic, or trauma surgery patients. Retrospective study. Intermediate care facility and general ward of a university hospital. 502 patients who received epidural catheters after abdominal, thoracic, or vascular surgery at our institution from January 1996 to December 2000. Placement of an epidural catheter, which was used for postoperative pain treatment, for more than 24 hours. The puncture site dressing included saturation each day with povidone-iodine. Microbiologic monitoring of epidural catheter tips and daily examination of puncture sites with regard to signs of inflammation took place. Four times daily patients were examined to check adequacy of pain treatment and neurologic deficits. Catheter tip cultures were positive in 29 patients (5.8%). Staphylococcus epidermidis was isolated in 22 cases (76%). No case of spinal epidural abscess was observed within 6 months after epidural catheterization. The average catheterization time was 5 days (quartile range: 4 to 6 days). Meticulous management ensures a relatively low level of bacterial contamination in epidural catheters applied for postoperative pain treatment greater than 5 days. Contamination rarely leads to spinal epidural infection.

  20. Detection of electrophysiology catheters in noisy fluoroscopy images.

    PubMed

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  1. Ultrasound-guided Combined Fascial Plane Blocks as an Intervention for Pain Management after Laparoscopic Cholecystectomy: A Randomized Control Study

    PubMed Central

    Ramkiran, Seshadri; Jacob, Mathews; Honwad, Manish; Vivekanand, Desiraju; Krishnakumar, Mathangi; Patrikar, Seema

    2018-01-01

    Background: Pain associated with laparoscopic cholecystectomy is most severe during the first 24 h and the port sites are the most painful. Recent multimodal approaches target incisional pain instead of visceral pain which has led to the emergence of abdominal fascial plane blocks. This study embraces a novel combination of two independently effective fascial plane blocks, namely rectus sheath block and subcostal transversus abdominis plane (TAP) block to alleviate postoperative pain. Study Objective: The aim is to evaluate the effectiveness of the combination of rectus sheath block and subcostal TAP block, to compare its efficacy with that of subcostal TAP block alone and with conventional port site infiltration (PSI) in alleviating postoperative pain in patients undergoing laparoscopic cholecystectomy. Methodology: This prospective, randomized control, pilot study included 61 patients scheduled for elective laparoscopic cholecystectomy and distributed among three groups, namely Group 1: Combined subcostal TAP block with rectus sheath block (n = 20); Group 2: Oblique subcostal TAP block alone (n = 21); and Group 3: PSI group as an active control (n = 20). Results: Combined group had significantly lower pain scores, higher satisfaction scores, and reduced rescue analgesia both in early and late postoperative periods than the conventional PSI group. Conclusion: Ultrasound-guided combined fascial plane blocks is a novel intervention in pain management of patients undergoing laparoscopic cholecystectomy and should become the standard of care. PMID:29628547

  2. A novel, inexpensive, double lumen suprapubic catheter for urodynamics.

    PubMed

    Wagner, Andrew A; Godley, Margaret L; Duffy, Patrick G; Ransley, Philip G

    2004-03-01

    We describe a novel, double lumen, intravesical, suprapubic catheter designed to meet the requirements of pediatric urodynamics that is easy to use and has minimal complications. A commercially available 10Fr pediatric suprapubic pigtail catheter forms the outer lumen for instilling filling media. A 16 gauge epidural catheter is inserted through the outer catheter providing an inner lumen for measuring intravesical pressures. The resultant double-lumen catheter is inserted suprapubically using a peel away needle supplied with the 10Fr catheter, with the patient under general anesthetic. The catheter has been used for 15 years in more than 700 patients with good reliability and few complications. The concentric construction of the double lumens and the rigidity of the inner intravesical pressure channel ensure there is no transmission of pressure from the filling channel to the inner lumen. The catheter has a circular cross section and a pigtail distal end which help to retain it within the bladder. There is low resistance to filling that allows adequate filling rates to be achieved by gravity rather than necessitating a pump. The catheter is easily made from readily available components and is less expensive than other double-lumen catheters suitable for suprapubic use. A reliable, double lumen catheter that fulfills criteria not found in commercially available alternatives can be inexpensively made for urodynamics.

  3. Use of monorail PTCA balloon catheter for local drug delivery.

    PubMed

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  4. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    PubMed Central

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  5. Diastasis recti abdominis during pregnancy and 12 months after childbirth: prevalence, risk factors and report of lumbopelvic pain

    PubMed Central

    Tennfjord, Merete Kolberg; Hilde, Gunvor; Ellström-Engh, Marie; Bø, Kari

    2016-01-01

    Background/aim Diastasis recti abdominis (DRA) is defined as a separation of the 2 muscle bellies of rectus abdominis. To date there is scant knowledge on prevalence, risk factors, and consequences of the condition. The present study aimed to investigate the prevalence of DRA during pregnancy and post partum, presence of possible risk factors, and the occurrence of lumbopelvic pain among women with and without DRA. Methods This prospective cohort study followed 300 first-time pregnant women from pregnancy till 12 months post partum. Data were collected by electronic questionnaire and clinical examinations. DRA was defined as a palpated separation of ≥2 fingerbreadths either 4.5 cm above, at or 4.5 cm below the umbilicus. Women with and without DRA were compared with independent samples Student's t-test and χ2/Fisher exact test, and OR with significance level >0.05. Results Prevalence of DRA was 33.1%, 60.0%, 45.4%, and 32.6% at gestation week 21, 6 weeks, 6 months and 12 months post partum, respectively. No difference in risk factors was found when comparing women with and without DRA. OR showed a greater likelihood for DRA among women reporting heavy lifting ≥20 times weekly (OR 2.18 95% CI 1.05 to 4.52). There was no difference in reported lumbopelvic pain (p=0.10) in women with and without DRA. Conclusions Prevalence of mild DRA was high both during pregnancy and after childbirth. Women with and without DRA reported the same amount of lumbopelvic pain 12 months post partum. PMID:27324871

  6. Cocontraction of Ankle Dorsiflexors and Transversus Abdominis Function in Patients With Low Back Pain

    PubMed Central

    Chon, Seung-Chul; You, Joshua H.; Saliba, Susan A.

    2012-01-01

    Context The abdominal draw-in maneuver (ADIM) with cocontraction has been shown to be a more effective method of activating the transversus abdominis (TrA) in healthy adults than the ADIM alone. Whether such an augmented core stabilization exercise is effective in managing low back pain (LBP) remains uncertain. Objective To determine the effect of 2 weeks of ADIM and cocontraction training on abdominal muscle thickness and activation timing and to monitor pain and function in patients with LBP. Design Case-control study. Setting Local orthopaedic clinic and research laboratory. Patients or Other Participants Twenty patients with mechanical LBP (age = 27.20 ± 6.46 years, height = 166.25 ± 8.70 cm, mass = 58.10 ± 11.81 kg) and 20 healthy, age-matched people (age = 24.25 ± 1.59 years, height = 168.00 ± 8.89 cm, mass = 60.65 ± 11.99 kg) volunteered for the study. Intervention(s) Both the LBP and control groups received ten 30-minute sessions of ADIM and cocontraction training of the tibialis anterior (TA) and rectus femoris (RF) muscles over a 2-week period. Main Outcome Measure(s) A separate, mixed-model analysis of variance was computed for the thicknesses of the TrA, internal oblique (IO), and external oblique muscles. The differences in mean and peak electromyographic (EMG) amplitudes, onset time, and latency were compared between the groups. The visual analog pain scale, Pain Disability Index, and LBP rating scale were used to assess pain in the LBP group before and after the intervention. Results We found an interaction between the LBP and control groups and a main effect from pretest to posttest for only TrA muscle thickness change (F1,38 = 6.57, P = .01). Reductions in all pain measures were observed after training (P < .05). Group differences in peak and mean EMG amplitudes and onset time values for TrA/IO and TA were achieved (P < .05). The RF peak (t38 = −3.12, P = .003) and mean (t38 = −4.12, P = .001) EMG amplitudes were different, but no group

  7. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    PubMed

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (p<0.001). Perfusion of amiodarone [adjusted OR (AOR) 25.97; 95% CI=7.29-92.55, p=0.0001] and cefotaxime (AOR 2.90; 95% CI=1.29-6.52, p=0.01) and the shift when the catheters were placed (AOR for morning vs. night shift 0.60; 95% CI=0.35-1.02, p=0.063) were independently associated to the development of PPIVC. A history of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  8. Fourier plane filters

    NASA Technical Reports Server (NTRS)

    Oliver, D. S.; Aldrich, R. E.; Krol, F. T.

    1972-01-01

    An electrically addressed liquid crystal Fourier plane filter capable of real time optical image processing is described. The filter consists of two parts: a wedge filter having forty 9 deg segments and a ring filter having twenty concentric rings in a one inch diameter active area. Transmission of the filter in the off (transparent) state exceeds fifty percent. By using polarizing optics, contrast as high as 10,000:1 can be achieved at voltages compatible with FET switching technology. A phenomenological model for the dynamic scattering is presented for this special case. The filter is designed to be operated from a computer and is addressed by a seven bit binary word which includes an on or off command and selects any one of the twenty rings or twenty wedge pairs. The overall system uses addressable latches so that once an element is in a specified state, it will remain there until a change of state command is received. The drive for the liquid crystal filter is ? 30 V peak at 30 Hz to 70 Hz. These parameters give a rise time for the scattering of 20 msec and a decay time of 80 to 100 msec.

  9. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    PubMed

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  10. Bending stiffness of catheters and guide wires.

    PubMed

    Wünsche, P; Werner, C; Bloss, P

    2002-01-01

    An important property of catheters and guide wires to assess their pushability behavior is their bending stiffness. To measure bending stiffness, a new bending module with a new clamping device was developed. This module can easily be mounted in commercially available tensile testing equipment, where bending force and deflection due to the bending force can be measured. To achieve high accuracy for the bending stiffness, the bending distance has to be measured with even higher accuracy by using a laser-scan micrometer. Measurement results of angiographic catheters and guide wires were presented and discussed. The bending stiffness shows a significant dependence on the angle of the test specimen's rotation around its length axis.

  11. Distributed pressure sensors for a urethral catheter.

    PubMed

    Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, A S

    2015-01-01

    A flexible strip that incorporates multiple pressure sensors and is capable of being fixed to a urethral catheter is developed. The urethral catheter thus instrumented will be useful for measurement of pressure in a human urethra during urodynamic testing in a clinic. This would help diagnose the causes of urinary incontinence in patients. Capacitive pressure sensors are fabricated on a flexible polyimide-copper substrate using surface micromachining processes and alignment/assembly of the top and bottom portions of the sensor strip. The developed sensor strip is experimentally evaluated in an in vitro test rig using a pressure chamber. The sensor strip is shown to have adequate sensitivity and repeatability. While the calibration factors for the sensors on the strip vary from one sensor to another, even the least sensitive sensor has a resolution better than 0.1 psi.

  12. Pancreas tumor interstitial pressure catheter measurement

    NASA Astrophysics Data System (ADS)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  13. Catheter closure of secundum atrial septal defects.

    PubMed

    O'Laughlin, M P

    1997-01-01

    Catheter occlusion of atrial septal defects has its roots in the 1950s, with early devices being implanted during closed-heart surgery without cardiopulmonary bypass. For the past 20 years, various catheter-delivered devices have undergone testing and refinement. Designs have included single- and double-disk prostheses, with a variety of materials, delivery systems, and techniques. In this monograph, the history of atrial septal defect occluders and their evaluation, results, and prognoses will be outlined. The early work of King and Mills has been advanced in the forms of the Rashkind and Lock-USCI Clamshell occluders (USCI; Billerica, Mass), the "buttoned" device (custom made by E.B. Sideris), the Babic atrial septal defect occlusion system (Osypka, GmbH; Grenzach-Wyhlen, Germany), the Das-Angel Wings atrial septal defect occlusion device (Microvena Corporation; White Bear Lake, Minn), and others. The future holds promise for approved devices in the treatment of selected secundum atrial septal defects.

  14. Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study.

    PubMed

    Arya, Arash; Zaker-Shahrak, Ruzbeh; Sommer, Phillip; Bollmann, Andreas; Wetzel, Ulrike; Gaspar, Thomas; Richter, Sergio; Husser, Daniela; Piorkowski, Christopher; Hindricks, Gerhard

    2011-01-01

    To compare the acute and the 6 month outcome of catheter ablation of atrial fibrillation (AF) using irrigated tip magnetic catheter and remote magnetic cathter navigation (RMN) with manual catheter navigation (MCN) in patients with paroxysmal and persistent AF. In this retrospective analysis 356 patients (235 male, mean age: 57.9 ± 10.9 years) with AF (70.5%, paroxysmal) who underwent catheter ablation between August 2007 and May 2008 using either RMN (n = 70, 46 male, mean age: 57.9 ± 10.1 years, 50% paroxysmal) or MCN (n = 286, 189 male, mean age: 58.0 ± 13.9 years, 75.5% paroxysmal) were included. All patients completed an intensive follow-up strategy. Complete pulmonary vein isolation was achieved in 87.6 and 99.6% of patients in RMN and MCN groups, respectively (P < 0.05). The procedure, fluoroscopy, and radiofrequency application times were 223 ± 44 vs. 166 ± 52 min (P < 0.0001), 13.7 ± 7.8 vs. 34.5 ± 15.1 min (P < 0.0001), and 75.4 ± 20.9 vs. 53.2 ± 21.4 min (P < 0.0001) in RMN and MCN groups, respectively. Seven (10.0%) and 28 (9.8%) patients in RMN and MCN groups received antiarrhythmic medications during the follow-up (P = 0.96). All the patients completed the 6 month follow-up. Freedom from AF at 6 months was achieved in 57.8 and 66.4% of the patients in RMN and MCN groups, respectively (P = 0.196). In patients without previous AF catheter ablation procedure the freedom from AF at 6 months were 68.2 and 60.5% in the MCN and RMN groups, respectively (P = 0.36). Catheter ablation using irrigated tip magnetic catheter and RMN is an effective and safe method for catheter ablation of AF. Compared to manual catheter navigation, the procedure and radiofrequency application times were longer and fluoroscopy time was shorter in the RMN group compared with the MCN group.

  15. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    PubMed Central

    Urbanetto, Janete de Souza; Peixoto, Cibelle Grassmann; May, Tássia Amanda

    2016-01-01

    ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC) and following their removal - (post-infusion phlebitis) in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective. PMID:27508916

  16. Baclofen pump catheter leakage after migration of the abdominal catheter in a pediatric patient with spasticity.

    PubMed

    Dastgir, Amer; Ranalli, Nathan J; MacGregor, Theresa L; Aldana, Philipp R

    2015-09-01

    The authors report an unusual case of intrathecal baclofen withdrawal due to the perforation and subsequent leakage of a baclofen pump catheter in a patient with spastic cerebral palsy. A 15-year-old boy underwent an uncomplicated placement of an intrathecal baclofen pump for the treatment of spasticity due to cerebral palsy. After excellent control of symptoms for 3 years, the patient presented to the emergency department with increasing tremors following a refill of his baclofen pump. Initial evaluation consisted of radiographs of the pump and catheter, which appeared normal, and a successful aspiration of CSF from the pump's side port. A CT dye study revealed a portion of the catheter directly overlying the refill port and extravasation of radiopaque dye into the subfascial pocket anterior to the pump. During subsequent revision surgery, a small puncture hole in the catheter was seen to be leaking the drug. The likely cause of the puncture was an inadvertent perforation of the catheter by a needle during the refilling of the pump. This case report highlights a unique complication in a patient with an intrathecal baclofen pump. Physicians caring for these patients should be aware of this rare yet potential complication in patients presenting with baclofen withdrawal symptoms.

  17. Alternate energy sources for catheter ablation.

    PubMed

    Wang, P J; Homoud, M K; Link, M S; Estes III, N A

    1999-07-01

    Because of the limitations of conventional radiofrequency ablation in creating large or linear lesions, alternative energy sources have been used as possible methods of catheter ablation. Modified radiofrequency energy, cryoablation, and microwave, laser, and ultrasound technologies may be able to create longer, deeper, and more controlled lesions and may be particularly suited for the treatment of ventricular tachycardias and for linear atrial ablation. Future studies will establish the efficacy of these new and promising technologies.

  18. Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

    PubMed

    Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J

    2008-07-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.

  19. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    PubMed

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (p<0.001). The median angles of the catheter tip were 7.8° and 4.1°, respectively (p<0.001). Phlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  20. 3D localization of electrophysiology catheters from a single x-ray cone-beam projection

    SciTech Connect

    Robert, Normand, E-mail: normand.robert@sri.utoronto.ca; Polack, George G.; Sethi, Benu

    2015-10-15

    Purpose: X-ray images allow the visualization of percutaneous devices such as catheters in real time but inherently lack depth information. The provision of 3D localization of these devices from cone beam x-ray projections would be advantageous for interventions such as electrophysiology (EP), whereby the operator needs to return a device to the same anatomical locations during the procedure. A method to achieve real-time 3D single view localization (SVL) of an object of known geometry from a single x-ray image is presented. SVL exploits the change in the magnification of an object as its distance from the x-ray source is varied.more » The x-ray projection of an object of interest is compared to a synthetic x-ray projection of a model of said object as its pose is varied. Methods: SVL was tested with a 3 mm spherical marker and an electrophysiology catheter. The effect of x-ray acquisition parameters on SVL was investigated. An independent reference localization method was developed to compare results when imaging a catheter translated via a computer controlled three-axes stage. SVL was also performed on clinical fluoroscopy image sequences. A commercial navigation system was used in some clinical image sequences for comparison. Results: SVL estimates exhibited little change as x-ray acquisition parameters were varied. The reproducibility of catheter position estimates in phantoms denoted by the standard deviations, (σ{sub x}, σ{sub y}, σ{sub z}) = (0.099 mm,  0.093 mm,  2.2 mm), where x and y are parallel to the detector plane and z is the distance from the x-ray source. Position estimates (x, y, z) exhibited a 4% systematic error (underestimation) when compared to the reference method. The authors demonstrated that EP catheters can be tracked in clinical fluoroscopic images. Conclusions: It has been shown that EP catheters can be localized in real time in phantoms and clinical images at fluoroscopic exposure rates. Further work is required to

  1. An ovine model of cerebral catheter venography for implantation of an endovascular neural interface.

    PubMed

    Oxley, Thomas James; Opie, Nicholas Lachlan; Rind, Gil Simon; Liyanage, Kishan; John, Sam Emmanuel; Ronayne, Stephen; McDonald, Alan James; Dornom, Anthony; Lovell, Timothy John Haynes; Mitchell, Peter John; Bennett, Iwan; Bauquier, Sebastien; Warne, Leon Norris; Steward, Chris; Grayden, David Bruce; Desmond, Patricia; Davis, Stephen M; O'Brien, Terence John; May, Clive N

    2018-04-01

    OBJECTIVE Neural interface technology may enable the development of novel therapies to treat neurological conditions, including motor prostheses for spinal cord injury. Intracranial neural interfaces currently require a craniotomy to achieve implantation and may result in chronic tissue inflammation. Novel approaches are required that achieve less invasive implantation methods while maintaining high spatial resolution. An endovascular stent electrode array avoids direct brain trauma and is able to record electrocorticography in local cortical tissue from within the venous vasculature. The motor area in sheep runs in a parasagittal plane immediately adjacent to the superior sagittal sinus (SSS). The authors aimed to develop a sheep model of cerebral venography that would enable validation of an endovascular neural interface. METHODS Cerebral catheter venography was performed in 39 consecutive sheep. Contrast-enhanced MRI of the brain was performed on 13 animals. Multiple telescoping coaxial catheter systems were assessed to determine the largest wide-bore delivery catheter that could be delivered into the anterior SSS. Measurements of SSS diameter and distance from the motor area were taken. The location of the motor area was determined in relation to lateral and superior projections of digital subtraction venography images and confirmed on MRI. RESULTS The venous pathway from the common jugular vein (7.4 mm) to the anterior SSS (1.2 mm) was technically challenging to selectively catheterize. The SSS coursed immediately adjacent to the motor cortex (< 1 mm) for a length of 40 mm, or the anterior half of the SSS. Attempted access with 5-Fr and 6-Fr delivery catheters was associated with longer procedure times and higher complication rates. A 4-Fr catheter (internal lumen diameter 1.1 mm) was successful in accessing the SSS in 100% of cases with no associated complications. Complications included procedure-related venous dissection in two major areas: the torcular

  2. Current status of endovascular catheter robotics.

    PubMed

    Lumsden, Alan B; Bismuth, Jean

    2018-06-01

    In this review, we will detail the evolution of endovascular therapy as the basis for the development of catheter-based robotics. In parallel, we will outline the evolution of robotics in the surgical space and how the convergence of technology and the entrepreneurs who push this evolution have led to the development of endovascular robots. The current state-of-the-art and future directions and potential are summarized for the reader. Information in this review has been drawn primarily from our personal clinical and preclinical experience in use of catheter robotics, coupled with some ground-breaking work reported from a few other major centers who have embraced the technology's capabilities and opportunities. Several case studies demonstrating the unique capabilities of a precisely controlled catheter are presented. Most of the preclinical work was performed in the advanced imaging and navigation laboratory. In this unique facility, the interface of advanced imaging techniques and robotic guidance is being explored. Although this procedure employs a very high-tech approach to navigation inside the endovascular space, we have conveyed the kind of opportunities that this technology affords to integrate 3D imaging and 3D control. Further, we present the opportunity of semi-autonomous motion of these devices to a target. For the interventionist, enhanced precision can be achieved in a nearly radiation-free environment.

  3. Permcath Catheter Embolization: a Case Report

    PubMed Central

    Yousefshahi, Hadi; Bina, Payvand; Yousefshahi, Fardin

    2015-01-01

    Introduction: Nowadays, many types of intravascular devices and catheters are used in order to diagnose and treat diseases. Complications related to these instruments are the costs that doctors and patients have to pay to benefit from their advantages. Catheter embolization is one of these side effects. Patients with devices in their cardiopulmonary system are at risk for severe complications such as arrhythmias, pulmonary embolism, myocardial injuries, hemoptysis, thrombosis and perforation. Case Presentation: A 50-years-old woman, with a history of breast cancer, had a PermCath emplacement in right subclavian vein for a course of chemotherapy. The treatment for cancer seemed to be successful and the PermCath had remained in its position without complication, for a couple of years however, the catheter was founded broken and embolized to the right ventricle and the main left pulmonary artery, diagnosed by a chest X-ray study incidentally. Conclusions: It is better to remove the unused devices safely to prevent and decrease their possible complications. PMID:25964881

  4. Permcath catheter embolization: a case report.

    PubMed

    Yousefshahi, Hadi; Bina, Payvand; Yousefshahi, Fardin

    2015-04-01

    Nowadays, many types of intravascular devices and catheters are used in order to diagnose and treat diseases. Complications related to these instruments are the costs that doctors and patients have to pay to benefit from their advantages. Catheter embolization is one of these side effects. Patients with devices in their cardiopulmonary system are at risk for severe complications such as arrhythmias, pulmonary embolism, myocardial injuries, hemoptysis, thrombosis and perforation. A 50-years-old woman, with a history of breast cancer, had a PermCath emplacement in right subclavian vein for a course of chemotherapy. The treatment for cancer seemed to be successful and the PermCath had remained in its position without complication, for a couple of years however, the catheter was founded broken and embolized to the right ventricle and the main left pulmonary artery, diagnosed by a chest X-ray study incidentally. It is better to remove the unused devices safely to prevent and decrease their possible complications.

  5. Viewing Saturn from the Plane

    NASA Image and Video Library

    2006-04-19

    This view of the ringed planet shows its tilt relative to the plane of its orbit around the Sun. The planet tilts nearly 27 degrees relative to the ecliptic plane giving rise to seasons in which the rings shadow each hemisphere in its respective winter

  6. [Biodegradable catheters and urinary stents. When?

    PubMed

    Soria, F; Morcillo, E; López de Alda, A; Pastor, T; Sánchez-Margallo, F M

    2016-10-01

    One of the main wishes in the field of urinary catheters and stents is to arm them with biodegradable characteristics because we consider a failure of these devices the need for retrieval, the forgotten catheter syndrome as well as the adverse effects permanent devices cause after fulfilling their aim. The efforts focused in new designs, coatings and biomaterials aim to increase the biocompatibility of theses internal devices. Lately, there have been correct advances to answer the main challenges regarding biodegradable ureteral devices. Thus, modulation of the rate of degradation has been achieved thanks to new biomaterials and the use of copolymers that enable to choose the time of permanence as it is programmed with conventional double J catheters. Biocompatibility has improved with the use of new polymers that adapt better to the urine. Finally, one of the main problems is elimination of degraded fragments and experimentally it has be demonstrated that new designs elicit controlled degradation, from distal to proximal; using stranding and combination of copolymers degradation may be caused by dilution, reducing fragmentation to the last stages of life of the prosthesis. Moreover, it has been demonstrated that biodegradable catheters potentially may cause less urinary tract infection, less encrustation and predictably they will diminish catheter morbidity, since their degradation process reduces adverse effects. Regarding the development of biodegradable urethral stents, it is necessary to find biomaterials that enable maintaining their biomechanical properties in the long term, keeping open the urethral lumen both in patients with BPH and urethral stenosis. Modulation of the time of degradation of the prosthesis has been achieved, but the appearance of urothelial hyperplasia is still a constant in the initial phases after implantation. The development of drug eluting stents, anti-proliferative or anti-inflammatory, as well as biodegradable stents biocoated is a

  7. Evaluation of three-dimensional printing for internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach: a preliminary report.

    PubMed

    Zeng, Canjun; Xiao, Jidong; Wu, Zhanglin; Huang, Wenhua

    2015-01-01

    The aim of this study is to evaluate the efficacy and feasibility of three-dimensional printing (3D printing) assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach. A total of 38 patients with unstable pelvic fractures were analyzed retrospectively from August 2012 to February 2014. All cases were treated operatively with internal fixation assisted by three-dimensional printing from minimal invasive para-rectus abdominis approach. Both preoperative CT and three-dimensional reconstruction were performed. Pelvic model was created by 3D printing. Data including the best entry points, plate position and direction and length of screw were obtained from simulated operation based on 3D printing pelvic model. The diaplasis and internal fixation were performed by minimal invasive para-rectus abdominis approach according to the optimized dada in real surgical procedure. Matta and Majeed score were used to evaluate currative effects after operation. According to the Matta standard, the outcome of the diaplasis achieved 97.37% with excellent and good. Majeed assessment showed 94.4% with excellent and good. The imageological examination showed consistency of internal fixation and simulated operation. The mean operation time was 110 minutes, mean intraoperative blood loss 320 ml, and mean incision length 6.5 cm. All patients have achieved clinical healing, with mean healing time of 8 weeks. Three-dimensional printing assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach is feasible and effective. This method has the advantages of trauma minimally, bleeding less, healing rapidly and satisfactory reduction, and worthwhile for spreading in clinical practice.

  8. Establishing Immediate Reliability of Sonographic Measurements of the Transversus Abdominis in Asymptomatic Adults Performing Upright Loaded Functional Tasks in a Clinical Context Without Delayed Recorded Measurement.

    PubMed

    McPherson, Sue; Watson, Todd; Pate, Lindsey

    2016-08-01

    This study examined the reliability of sonographic measurements of the transversus abdominis of adults without low back pain during upright loaded functional tasks in real time, without relying on delayed recorded images. A single-group repeated-measures reliability study was conducted on 12 healthy participants without low back pain. Six of these adults reported a prior history of abdominal drawing-in maneuver training without sonographic measurement. The participants performed 3 trials of neutral standing, a loaded forward reach, and a loaded box lift under rest and with abdominal drawing-in maneuver instructions; task order was randomized. Transversus abdominis thickness measurements were obtained by an experienced rater using B-mode sonography in real-time via electronic calipers twice on the same static image during all trials by a rater. The rater was masked to group assignment and on-screen measurement output and required to respond to trivia questions between repeated measurements. The participants included 6 male and 6 female adults with a mean age ± SD of 26.3 ± 3.7 years. Intra-rater intraclass correlation coefficients (2,3) were high and precise for the rater's first and second measurements for all tasks and instruction conditions for mean transversus abdominis thickness and percent change in thickness measurements (eg, ranges were 0.968-0.997 for intraclass correlation coefficients, 0.01-0.21 mm for standard errors of the measurement, and 0.01-0.58 mm for minimal detectable changes). Calipers cleared by the rater or a research assistant produced similar findings of excellent reliability and precision. High intra-rater reliability and precision of transversus abdominis thickness measurements were obtained by a physical therapist in real time from asymptomatic adults performing upright loaded functional tasks under rest and with abdominal drawing-in maneuver instructions.

  9. Do various baseline characteristics of transversus abdominis and lumbar multifidus predict clinical outcomes in nonspecific low back pain? A systematic review.

    PubMed

    Wong, Arnold Y L; Parent, Eric C; Funabashi, Martha; Stanton, Tasha R; Kawchuk, Gregory N

    2013-12-01

    Although individual reports suggest that baseline morphometry or activity of transversus abdominis or lumbar multifidus predict clinical outcome of low back pain (LBP), a related systematic review is unavailable. Therefore, this review summarized evidence regarding the predictive value of these muscular characteristics. Candidate publications were identified from 6 electronic medical databases. After review, 5 cohort studies were included. Although this review intended to encompass studies using different muscle assessment methods, all included studies coincidentally used ultrasound imaging. No research investigated the relation between static morphometry and clinical outcomes. Evidence synthesis showed limited evidence supporting poor baseline transversus abdominis contraction thickness ratio as a treatment effect modifier favoring motor control exercise. Limited evidence supported that high baseline transversus abdominis lateral slide was associated with higher pain intensity after various exercise interventions at 1-year follow-up. However, there was limited evidence for the absence of relation between the contraction thickness ratio of transversus abdominis or anticipatory onset of lateral abdominal muscles at baseline and the short- or long-term LBP intensity after exercise interventions. There was conflicting evidence for a relation between baseline percent thickness change of lumbar multifidus during contraction and the clinical outcomes of patients after various conservative treatments. Given study heterogeneity, the small number of included studies and the inability of conventional greyscale B-mode ultrasound imaging to measure muscle activity, our findings should be interpreted with caution. Further large-scale prospective studies that use appropriate technology (ie, electromyography to assess muscle activity) should be conducted to investigate the predictive value of morphometry or activity of these muscles with respect to LBP-related outcomes measures

  10. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    PubMed

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  11. Is it feasible to diagnose catheter-related candidemia without catheter withdrawal?

    PubMed

    Fernández-Cruz, Ana; Martín-Rabadán, Pablo; Suárez-Salas, Marisol; Rojas-Wettig, Loreto; Pérez, María Jesús; Guinea, Jesús; Guembe, María; Peláez, Teresa; Sánchez-Carrillo, Carlos; Bouza, Emilio

    2014-07-01

    Many bloodstream infections (BSI) in patients with central venous catheters (CVC) are not catheter-related (CR). Assessment of catheter involvement without catheter withdrawal has not been studied in candidemia. We assessed the value of conservative techniques to evaluate catheters as the origin of candidemia in patients with CVC in a prospective cohort study (superficial Gram stain and culture, Kite technique (Gram stain and culture of the first 1 cm blood drawn from the CVC), proportion of positive blood cultures (PPBCs), differential time to positivity (DTP), and minimal time to positivity (MTP)). All catheters were cultured at withdrawal. From June 2008 to January 2012, 22 cases fulfilled the inclusion criteria. CR-candidemia (CRC) was confirmed in 10. Validity values for predicting CRC were: superficial Gram stain (S, 30%; Sp, 81.83%; PPV, 60%; NPV, 56.3%; Ac, 57.1%), superficial cultures (S, 40%; Sp, 75%; PPV, 57.1%; NPV, 60%; Ac, 59.1%), Kite Gram stain (S, 33.3%; Sp, 66.7%; PPV, 50%; NPV, 50%; Ac, 50%), Kite culture (S, 80%; Sp, 66.7%; PPV, 66.7%; NPV, 80%; Ac, 72.7%), PPBC (S, 50%; Sp, 41.7%; PPV, 41.7%; NPV, 50.0%; Ac, 45.5%), DTP (S, 100%; Sp, 33.3%; PPV, 55.6%; NPV, 100%; Ac, 63.6%), and MTTP (S, 70%; Sp, 58.3%; PPV, 58.3%; NPV, 70%; Ac, 63.6%). While combinations of two tests improved sensitivity and NPV, more than two tests did not improve validity values. Classic tests to assess CR-BSI caused by bacteria cannot be reliably used to diagnose CRC. Combinations of tests could be useful, but more and larger studies are required. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Balloon catheter versus basket catheter for endoscopic bile duct stone extraction: a multicenter randomized trial.

    PubMed

    Ishiwatari, Hirotoshi; Kawakami, Hiroshi; Hisai, Hiroyuki; Yane, Kei; Onodera, Manabu; Eto, Kazunori; Haba, Shin; Okuda, Toshinori; Ihara, Hideyuki; Kukitsu, Takehiro; Matsumoto, Ryusuke; Kitaoka, Keisuke; Sonoda, Tomoko; Hayashi, Tsuyoshi

    2016-04-01

    Endoscopic bile duct stone (BDS) removal is a well-established treatment; however, the preference for basket or balloon catheters for extraction is operator-dependent. We therefore conducted a multicenter prospective randomized trial to compare catheter performance. We enrolled patients with a BDS diameter ≤ 10 mm and common bile duct diameter ≤ 15 mm. Participants were randomly assigned to groups that were treated with basket or balloon catheters between October 2013 and September 2014. The primary endpoint was the rate of complete clearance of the duct; the secondary endpoints were the rate and time to complete clearance in one endoscopic session. We initially enrolled 172 consecutive patients; 14 were excluded after randomization. The complete clearance rates were 92.3 % (72/78) in the balloon group and 80.0 % (64 /80) in the basket group. The difference in the rates between the two groups was 12.3 percentage points, indicating non-inferiority of the balloon method (non-inferiority limit -10 %; P < 0.001 for non-inferiority). Moreover, the balloon was superior to the basket (P = 0.037). The rate of complete clearance in one endoscopic session was 97.4 % using the balloon and 97.5 % using the basket (P = 1.00). The median times to complete clearance in one endoscopic session were 6.0 minutes (1 - 30) and 7.8 minutes (1 - 37) in the balloon and basket groups, respectively (P = 0.15). For extraction of BDSs ≤ 10 mm, complete endoscopic treatment with a single catheter is more likely when choosing a balloon catheter over a basket catheter.University Hospital Medical Information Network Trials Registry: UMIN000011887. © Georg Thieme Verlag KG Stuttgart · New York.

  13. A qualitative study exploring the value of a catheter passport.

    PubMed

    Jaeger, Melanie De; Fox, Fiona; Cooney, Geraldine; Robinson, Jacqueline

    2017-08-10

    Many patients leaving hospital with a catheter do not have sufficient information to self-care and can experience physical and psychological difficulties. This study aimed to explore how a patient-held catheter passport affects the experiences of patients leaving hospital with a urethral catheter, the hospital nurses who discharge them and the community nurses who provide ongoing care for them. Qualitative methods used included interviews, focus groups and questionnaires, and thematic analysis. Three major themes were reported-informing patients, informing nurses; improving catheter care, promoting self-management; and supporting transition. The catheter passport can bridge the existing information gap, improve care, promote self-care and help patients adjust to their catheter, especially if complemented by ongoing input from a nurse or other health professional.

  14. Double Guiding Catheters for Complex Percutaneous Coronary Intervention

    PubMed Central

    Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen

    2012-01-01

    A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243

  15. The effect of bridge exercise method on the strength of rectus abdominis muscle and the muscle activity of paraspinal muscles while doing treadmill walking with high heels.

    PubMed

    Kang, Taewook; Lee, Jaeseok; Seo, Junghoon; Han, Dongwook

    2017-04-01

    [Purpose] The purpose of this research is to investigate the effect of the method of bridge exercise on the change of rectus abdominis muscle and the muscle activity of paraspinal muscles while doing treadmill walking with high heels. [Subjects and Methods] The subjects of this research are healthy female students consisting of 10 persons performing bridge exercises in a supine group, 10 persons performing bridge exercises in a prone group, and 10 persons in a control group while in S university in Busan. Bridge exercise in supine position is performed in hook lying position. Bridge exercise in prone position is plank exercise in prostrate position. To measure the strength of rectus abdominis muscle, maintaining times of the posture was used. To measure the muscle activity of paraspinal muscles, EMG (4D-MT & EMD-11, Relive, Korea) was used. [Results] The strength of rectus abdominis muscle of both bridge exercises in the supine group and bridge exercises in the prone group increases significantly after exercise. The muscle activity of paraspinal muscle such as thoracic parts and lumbar parts in bridge exercises in the prone group decreases statistically while walking on a treadmill with high heels. Muscle activity of thoracic parts paraspinal muscle and bridge exercises in the supine group decreased significantly. [Conclusion] According to this study, we noticed that bridge exercise in a prone position is desirable for women who prefer wearing high heels as a back pain prevention exercise method.

  16. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions

    PubMed Central

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-01

    Case series Patient: Male, 77 • Male, 57 • Male, 73 Final Diagnosis: Coronary chronic total occlusion Symptoms: Angina pectoris Medication: — Clinical Procedure: Percutaneous coronary intervention of coronary chronic total occlusions Specialty: Cardiology Objective: Unusual setting of medical care Background: During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. Case Report: We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. Conclusions: This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability

  17. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions.

    PubMed

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-31

    BACKGROUND During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. CASE REPORT We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. CONCLUSIONS This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability, safety, and exchangeability of the device.

  18. [Incidence and risk factors for infections from hemodialysis catheters].

    PubMed

    Jean, G

    2001-01-01

    We report here a revue of hemodialysis catheter-related infections data published since 1985. The reported prevalence of bacteremia is 1 to 20% of catheters, and incidence is 0.72 to 9/1000 catheter-days. Local infection is reported in 6 to 63% of catheters and in 1 to 5/1000 catheter-days. Tunneled catheters and implantables chambers reported less infection rate. The most severe complication is endocarditis (4% rate). Death occurs in 8 to 20% of cases. Reported microbial data show that Staphylococcus aureus (SA) is responsible for most infections ahead of non-aureus Staphylococcus. SA skin colonisation is a risk factor for catheter colonisation and the first step of infection. On the other hand, the host immunity impairment in hemodialysis patients seems a significant risk factor. Iron overload, specially after blood transfusions, older age, diabetes mellitus, low serum albumin level, previous history of bacteremia and immunosuppressive treatment have been frequently involved. Other catheter-related factors are time of use, absence of tunnel and use for parenteral nutrition. Nurses plans, dressing type and frequency, nurses work experience are also important. In spite of recent progress in risk factor understanding, hemodialysis-related infection remains frequent. Multicentre studies are necessary to better evaluated care protocols and new catheter material.

  19. Multifunctional Catheters Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    PubMed Central

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Nikoozadeh, Amin; Oralkan, Omer; Khuri-Yakub, Pierre T.; Sahn, David J.

    2015-01-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters’ ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools. PMID:18986948

  20. Theory of porous catheters and their applications in intraparenchymal infusions.

    PubMed

    Raghavan, Raghu; Odland, Rick M

    2017-01-01

    Multiport catheters and catheters with a porous surface have been proposed for intraparenchymal infusions of therapeutics in fluid suspensions. Target diseases include brain cancer and serious neurodegenerative diseases, as well as peripheral tumors, for example in the prostate and the liver. We set up the theory for infusions from such devices, in particular the fluid flow equations which demand a coupling between the flow within the catheter and that in tissue. (Such a coupling is not necessary in the theory of infusion from single port catheters.) The new feature of such catheters, treated by our model, is revealed by infusions into inhomogeneous media. Multiport designs have the potential to overcome the limitation of single port catheters, for which the path of the fluid leaving the port is dominated by the inhomogeneities. We solve these equations for some simple cases to illustrate the key design features of porous catheters that show such advantages. The mathematics required for numerical solution with more realistic assumptions is also developed. We confirm the robustness of such catheters, when the ports are sufficiently resistive, against leakage paths that would compromise the infusions from catheters with one or a few large ports. The methods of this paper can be incorporated into a larger planning system for intraparenchymal infusions involving such devices.

  1. Prevention of catheter-associated urinary tract infection

    PubMed Central

    Trautner, Barbara W.; Hull, Richard A.; Darouiche, Rabih O.

    2010-01-01

    Purpose of review The underlying cause of catheter-associated urinary tract infection is biofilm formation by uropathogens on the urinary catheter. Biofilm is a relatively new concept in medicine, and current measures to prevent biofilm formation are inadequate. Considerable work is being done in this area, but little clinical progress has been made. The purpose of this review is to analyze recent publications concerning prevention of catheter-associated urinary tract infection. Recent findings Several recent studies have elucidated aspects of biofilm formation in catheter-associated urinary tract infection. Other researchers are working on methods to disrupt biofilm formation on catheter surfaces. At the same time, the magnitude of the problem of catheter-associated urinary tract infection has increased awareness of the effectiveness of basic infection control measures. A modern approach to infection control may include computerized ordering systems that minimize unnecessary days of catheterization. Finally, consumption of cranberry juice products and bacterial interference are two novel approaches to urinary tract infection prevention. Summary Biofilm-disrupting strategies offer promise for the future but have little immediate applicability. Implementation of infection control measures to improve catheter function and remove unnecessary catheters can be done at the present time. In general, prevention of catheter-associated urinary tract infection remains an elusive goal. More basic research at the level of pathogenesis is needed so that novel strategies can be designed. PMID:15647698

  2. Anti-fouling strategies for central venous catheters

    PubMed Central

    Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-01-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs. PMID:29399528

  3. Anti-fouling strategies for central venous catheters.

    PubMed

    Wallace, Alex; Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-12-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs.

  4. Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.

    PubMed

    Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam

    2006-11-01

    Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.

  5. Catheter-related bloodstream infection with removal of catheter in pediatric oncology patients: a 10-year experience in Taiwan.

    PubMed

    Chen, Shih-Hsiang; Yang, Chao-Ping; Jaing, Tang-Her; Lai, Jin-Yao; Hung, Iou-Jih

    2012-04-01

    Long-term central venous catheter (CVC) implantation has become more affordable in Taiwan since 1995. Surgical removal of the catheter may be the essential treatment for catheter-related bloodstream infections (CRBSI). The aim of this study was to evaluate the clinical features and microbial isolates in pediatric cancer patients with removal of CVC for CRBSI. The records of positive blood culture from hospitalized pediatric oncology patients between 1995 and 2004 were reviewed. One hundred and forty-three patients implanted with a long-term CVC were further identified. Seventeen catheters in 16 patients developed catheter-related bacteremia that needed catheter removal. The rate of catheter removal was 11.9%. The median device life was 7.7 months. Six catheters were removed within 3 months of insertion. Nine of the 17 catheters were removed from patient younger than 2 years. Eight infections occurred during severe neutropenia, and 6 patients had refractory or relapsed underlying disease. The cultural isolates were Gram-negative bacilli in 7, Gram-positive in 5, fungi in 5, and atypical mycobacterium in 1. The frequency of catheter removal for infection control was significantly higher in the first 5 years (1994-1999) compared to the last 5 years (2000-2004) (30.9 vs. 4.0%, p = 2.3 × 10(-4)). Factors such as microbiological isolates, age of infection, the status of malignancy, and neutropenia are related to catheter outcome. The reduction in patients with positive cultures needing removal of the catheters can be related to improved nursing care and more aggressive antibiotic therapy.

  6. Analysis of chronic morphologic changes of small bowel in electrically stimulated canine island-flap rectus abdominis muscle stomal sphincters.

    PubMed

    Majzoub, R K; Bardoel, J W; Ackermann, D; Maldonado, C; Barker, J; Stadelmann, W K

    2001-11-01

    Dynamic myoplasty to achieve fecal continence has been used in humans with varying results. A potential complication of the use of dynamic skeletal sphincters to attain fecal continence is the development of ischemic strictures within the bowel encircled by the functional sphincter. This study examines the histologic changes present in the bowel wall used to create a functional dynamic island-flap stomal sphincter in a chronic canine model. The rectus abdominis muscles of canines were used to create island-flap stomal sphincters. Eight dynamic island-flap stomal sphincters were created from the rectus abdominis muscles in mongrel dogs by wrapping them around a blind loop of distal ileum that was no longer in continuity with the terminal small bowel. Temporary pacing electrodes were secured intramuscularly near the intercostal nerve entry point and connected to a subcutaneously placed pulse stimulator. Two different training protocols resulting in different contractile properties were used: Program A (n = 4) and Program B (n = 4). The island-flap sphincters were trained over 3 months to generate stomal intraluminal pressures of more than 60 mmHg in all animals. The intact sphincters, normal bowel, and contralateral stomal bowel were obtained when the animals were killed. Specimens were processed with paraffin embedding, sectioned, and stained with trichrome and hematoxylin-and-eosin stains. Measurements of the different bowel layers were made with a micrometer. The muscular sphincters were biopsied before and after training. Fiber-type histochemistry was performed with a monoclonal antibody to the fast isoforms of myosin. Pretrained and posttrained skeletal muscle specimens were examined histologically. The bowel wall within the functional dynamic stomal sphincter did not exhibit any significant architectural changes related to ischemic fibrosis or mucosal damage. A significant fiber-type conversion was achieved in both training groups with Programs A and B, with a

  7. Robotic Transversus Abdominis Release (TAR): is it possible to offer minimally invasive surgery for abdominal wall complex defects?

    PubMed

    Amaral, Maria Vitória França DO; Guimarães, José Ricardo; Volpe, Paula; Oliveira, Flávio Malcher Martins DE; Domene, Carlos Eduardo; Roll, Sérgio; Cavazzola, Leandro Totti

    2017-01-01

    We describe the preliminary national experience and the early results of the use of robotic surgery to perform the posterior separation of abdominal wall components by the Transversus Abdominis Release (TAR) technique for the correction of complex defects of the abdominal wall. We performed the procedures between 04/2/2015 and 06/15/2015 and the follow-up time was up to six months, with a minimum of two months. The mean surgical time was five hours and 40 minutes. Two patients required laparoscopic re-intervention, since one developed hernia by peritoneal migration of the mesh and one had mesh extrusion. The procedure proved to be technically feasible, with a still long surgical time. Considering the potential advantages of robotic surgery and those related to TAR and the results obtained when these two techniques are associated, we conclude that they seem to be a good option for the correction of complex abdominal wall defects. RESUMO Descrevemos a experiência preliminar nacional na utilização da cirurgia robótica para realizar a separação posterior de componentes da parede abdominal pela técnica transversus abdominis release (TAR) na correção de defeitos complexos da parede abdominal e seus resultados precoces. As cirurgias foram realizadas entre 02/04/2015 e 15/06/2015 e o tempo de acompanhamento dos resultados foi de até seis meses, com tempo mínimo de dois meses. O tempo cirúrgico médio foi de cinco horas e 40 minutos. Dois pacientes necessitaram reintervenção por laparoscopia, pois um desenvolveu hérnia por migração peritoneal da tela e um teve escape da tela. A cirurgia provou ser factível do ponto de vista técnico, com um tempo cirúrgico ainda elevado. Tendo em vista as vantagens potenciais da cirurgia robótica e aquelas relacionadas ao TAR e os resultados obtidos ao se associar essas duas técnicas, conclui-se que elas parecem ser uma boa opção para a correção de defeitos complexos da parede abdominal.

  8. Coronary angioplasty with second generation Monorail catheters.

    PubMed

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Bladder irrigation in patients with indwelling catheters.

    PubMed

    Bruun, J N; Digranes, A

    1978-01-01

    The effect of intermittent bladder irrigation on the bacterial counts in urine samples was studied in patients with indwelling catheter and pre-existing urinary tract infection. Four different irrigating solutions were used. Irrigation with saline or 0.25% acetic acid had no effect on the urinary bacterial count. The bacterial counts were effectively reduced during intermittent irrigation both with 0.02% chlorhexidine and with 0.25% silver nitrate. Silver nitrate gave the greatest reduction of bacterial counts but chlorhexidine is preferable due to fewer side effects and greater convenience.

  10. The pulmonary artery catheter: a critical reappraisal.

    PubMed

    Gidwani, Umesh K; Mohanty, Bibhu; Chatterjee, Kanu

    2013-11-01

    Balloon floatation pulmonary artery catheters (PACs) have been used for hemodynamic monitoring in cardiac, medical, and surgical intensive care units since the 1970s. With the availability of newer noninvasive diagnostic modalities, particularly echocardiography, the frequency of diagnostic pulmonary artery catheterization has declined. In this review, the evolution of PACs, the results of nonrandomized and randomized studies in various clinical conditions, the uses and abuses of bedside hemodynamic monitoring, and current indications for pulmonary artery catheterization are discussed. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.

    PubMed

    Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim

    2017-05-01

    Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    PubMed

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  13. Catheter-Based Sensing In The Airways

    NASA Astrophysics Data System (ADS)

    Fouke, J. M.; Saunders, K. G.

    1988-04-01

    Studies attempting to define the role of the respiratory tract in heating and humidifying inspired air point to the need for sensing many variables including airway wall and airstream temperatures, humidity, and surface fluid pH and osmolarity. In order to make such measurements in vivo in human volunteers, catheter based technologies must be exploited both to assure subject safety and subject comfort. Miniturization of the electrodes or sensors becomes a top priority. This paper describes the use of thin-film microelectronic technology to fabricate a miniature, flexible sensor which can be placed directly onto the surface of the airway to measure the electrical conductance of the fluids present. From this information the osmolarity of the surface fluid was calculated. Physiologic evaluation of the device and corroboration of the calculations was performed in mongrel dogs. We also describe the successful application of current thermistor technology for the thermal mapping of the airways in humans in order to characterize the dynamic intrathoracic events that occur during breathing. The thermal probe consisted of a flexible polyvinyl tube that contained fourteen small thermistors fixed into the catheter. Data have been obtained in dozens of people, both normal subjects and asthmatic patients, under a variety of interventions. These data have substantively advanced the study of asthma, a particularly troublesome chronic obstructive pulmonary disorder.

  14. Prevention of catheter-related blood stream infection.

    PubMed

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  15. Urinary catheters: history, current status, adverse events and research agenda

    PubMed Central

    Feneley, Roger C. L.; Hopley, Ian B.; Wells, Peter N. T.

    2015-01-01

    Abstract For more than 3500 years, urinary catheters have been used to drain the bladder when it fails to empty. For people with impaired bladder function and for whom the method is feasible, clean intermittent self-catheterization is the optimal procedure. For those who require an indwelling catheter, whether short- or long-term, the self-retaining Foley catheter is invariably used, as it has been since its introduction nearly 80 years ago, despite the fact that this catheter can cause bacterial colonization, recurrent and chronic infections, bladder stones and septicaemia, damage to the kidneys, the bladder and the urethra, and contribute to the development of antibiotic resistance. In terms of medical, social and economic resources, the burden of urinary retention and incontinence, aggravated by the use of the Foley catheter, is huge. In the UK, the harm resulting from the use of the Foley catheter costs the National Health Service between £1.0–2.5 billion and accounts for ∼2100 deaths per year. Therefore, there is an urgent need for the development of an alternative indwelling catheter system. The research agenda is for the new catheter to be easy and safe to insert, either urethrally or suprapubically, to be retained reliably in the bladder and to be withdrawn easily and safely when necessary, to mimic natural physiology by filling at low pressure and emptying completely without damage to the bladder, and to have control mechanisms appropriate for all users. PMID:26383168

  16. 21 CFR 870.1370 - Catheter tip occluder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...

  17. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip pressure transducer. 870.2870 Section 870.2870 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2870 Catheter tip...

  18. 21 CFR 870.1240 - Flow-directed catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flow-directed catheter. 870.1240 Section 870.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1240 Flow-directed catheter...

  19. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  20. Blocked urinary catheters: solutions are not the only solution.

    PubMed

    Williams, Cath; Tonkin, Sharon

    2003-07-01

    The use of catheter maintenance solutions to manage clients whose catheters block has long been a subject for debate. An understanding of the causes of blockage, and awareness of appropriate management may reduce frequency of blockage and reduce unnecessary interruptions to a closed urinary drainage system.

  1. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    SciTech Connect

    Oh, Jung Suk, E-mail: oj-cumc@daum.net; Lee, Hae Giu, E-mail: hgleehfh@catholic.ac.kr; Chun, Ho Jong

    2013-10-15

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38)more » after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.« less

  2. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  3. 21 CFR 870.1240 - Flow-directed catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Flow-directed catheter. 870.1240 Section 870.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1240 Flow-directed catheter...

  4. 21 CFR 870.1370 - Catheter tip occluder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...

  5. 21 CFR 880.5210 - Intravascular catheter securement device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular catheter securement device. 880.5210 Section 880.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... and is used to keep the hub of the needle or the catheter flat and securely anchored to the skin. (b...

  6. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  7. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  8. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  9. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  10. A magnetic-resonance-imaging-compatible remote catheter navigation system.

    PubMed

    Tavallaei, Mohammad Ali; Thakur, Yogesh; Haider, Syed; Drangova, Maria

    2013-04-01

    A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within the bore of the magnet. While inside the scanner bore, motion accuracy was characterized during the acquisition of frequently used imaging sequences, including real-time gradient echo. The effect of the catheter navigation system on image signal-to-noise ratio (SNR) was also evaluated. The results show that the master-slave system has a maximum time delay of 41 ± 21 ms in replicating motion; an absolute value error of 2 ± 2° was measured for radial catheter motion replication over 360° and 1.0 ± 0.8 mm in axial catheter motion replication over 100 mm of travel. The worst-case SNR drop was observed to be 2.5%.

  11. The left atrial catheter: its uses and complications.

    PubMed

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  12. Candida tropicalis biofilms: artificial urine, urinary catheters and flow model.

    PubMed

    Negri, Melyssa; Silva, Sónia; Henriques, Mariana; Azeredo, Joana; Svidzinski, Terezinha; Oliveira, Rosário

    2011-10-01

    Adhesion to medical devices and biofilm formation are considered important virulence factors of Candida tropicalis. This work aimed to use artificial urine (AU) and urinary catheters, under flow conditions, for studying C. tropicalis biofilms. Adhesion and biofilm formation on silicone and latex urinary catheters were quantified by crystal violet staining and determination of colony forming units. Candida surface hydrophobicity was also evaluated, as well as the biofilms' matrix content in terms of proteins and carbohydrates. Candida tropicalis was able to adhere and to form biofilms along the entire length of the catheters under flow conditions. It was found that the isolate U69 adhered significantly more to both types of catheters than did the reference strain. However, U69 biofilms contained significantly less cultivable cells and higher biofilm biomass than those of the reference strain. Detachment of cells from biofilms on latex catheter was lower compared to silicone catheter. This model using AU appeared to be suitable for studies mimicking the real body conditions. Additionally, C. tropicalis was in fact able to colonize urinary catheters in the presence of AU and to detach from these catheters, demonstrating their capacity to colonize distal sites.

  13. 21 CFR 880.5210 - Intravascular catheter securement device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intravascular catheter securement device. 880.5210 Section 880.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... and is used to keep the hub of the needle or the catheter flat and securely anchored to the skin. (b...

  14. [Periinterventional prophylactic antibiotics in radiological port catheter implantation].

    PubMed

    Gebauer, B; Teichgräber, U; Werk, M; Wagner, H-J

    2007-08-01

    To evaluate whether catheter-related infections after radiologically placed port catheters can be reduced by single-shot periinterventional antibiosis. Between January and September 2002, 164 consecutive patients with indication for central venous port catheter implantation were included in the present study. During implantation the interventional radiologist was responsible for deciding whether to administer a prophylactic single-shot antibiosis. The prophylactic antibiosis entailed intravenous administration of ampicillin and sulbactam (3 g Unacid, Pfizer) or 100 mg ciprofloxacine (Ciprobay, Bayer) in the case of an allergy history to penicillins. Catheter-related infection was defined as a local or systemic infection necessitating port catheter extraction. Indication for port catheter implantation was a malignant disease requiring chemotherapy in 158 cases. The port catheter (Chemosite [Tyco Healthcare] [n = 123], low-profile [Arrow International] [n = 35], other port system [n = 6]) was implanted via sonographically guided puncture of the right jugular vein in 139 patients, via the left jugular vein in 24 cases and via the right subclavian vein in one patient. 75 patients received periinterventional prophylactic antibiosis (Unacid [n = 63] Ciprobay [n = 12]) and 89 patients did not receive antibiosis. The prophylactic antibiosis caused a minor allergic reaction in one patient that improved with antihistamic and corticoid medication. A total of 7 ports, 6 without prophylactic antibiosis versus one with periinterventional prophylaxis, were extracted due to infectious complications. Single-shot periinterventional prophylactic antibiosis can reduce early and late infectious complications after radiological-interventional placement of central venous port catheters.

  15. Factors associated with peritoneal dialysis catheter complications in children.

    PubMed

    Stewart, Camille L; Acker, Shannon N; Pyle, Laura L; Kulungowski, Ann; Cadnapaphornchai, Melissa; Bruny, Jennifer L; Karrer, Frederick

    2016-01-01

    Peritoneal dialysis (PD) is a common method of renal replacement therapy for children. However, placement of PD catheters has risk, and some are never used. We conducted a retrospective chart review of children with a PD catheter placed between 2000 and 2014. Logistic regression analyses were used to identify covariates associated with complications. We identified 175 children with PD catheters. 110 complications developed in 80 children (45.7%). Complications including unexpected return to the operating room and peritonitis increased as the length of time a catheter was in place increased. Children who weighed <12.4 kg had 3.2 times greater odds of developing a leak (95% CI 1.21-8.63, p=0.02). Twelve children never used their PD catheters, 9 with acute kidney injury (AKI) who recovered from their disease more quickly than expected. No covariate was associated with nonuse. Complications with PD catheters are common and increase the longer catheters are in place. Lower weight children are at greater risk of PD catheter leak. Decreased initial volumes of dialysate in smaller children may mitigate this risk. Nonuse may be reduced if dialysis is permitted the day of placement for children with AKI. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    PubMed

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  17. Duration and Adverse Events of Non-cuffed Catheter in Patients With Hemodialysis

    ClinicalTrials.gov

    2014-10-09

    Renal Failure Chronic Requiring Hemodialysis; Central Venous Catheterization; Inadequate Hemodialysis Blood Flow; Venous Stenosis; Venous Thrombosis; Infection Due to Central Venous Catheter; Central Venous Catheter Thrombosis

  18. A study of the effect of pregnancy on muscle fibers of the rectus abdominis muscle of the rat.

    PubMed

    Martin, W D

    1979-11-01

    Samples of the rectus abdominis muscle were taken from Sprague-Dawley rats at 0, 3, 6, 6, 12, 15, 18, and 21 days of pregnancy, and at 1, 3, 6, 9, 12, and 15 days of postpartum. Sections were incubated for actomyosin adenosine triphosphatase activity following preincubation at a basic pH. Muscle fibers within a unit area of each sample were identified as to fiber type according to their enzyme activity, and the population of each type counted. The proportion of each fiber type was calculated and the diameter of 24 fibers of each type measured. No changes were noted in the muscle fiber proportions through the course of the experiment. Differential changes in muscle fiber diameters were noted in each of the three muscle fiber types. Slow oxidative fibers underwent an increase in diameter through the last half of pregnancy. The diameter was further increased as stretch of the muscle was released after birth, and did not decrease in the postpartum period. Fast glycolytic fibers decreased in diameter during the last half of pregnancy, but returned to the prepregnancy diameter in the first postpartum day. The diameter of the fast oxidative glycolytic fibers remained unchanged through the course of pregnacy and in the postpartum period.

  19. Biophysics and pathology of catheter energy delivery systems.

    PubMed

    Nath, S; Haines, D E

    1995-01-01

    Catheter ablation has rapidly emerged as the treatment of choice for many symptomatic cardiac arrhythmias. The initial experience with catheter ablation used high-energy DC as the energy source. However, over the last several years radiofrequency (RF) catheter ablation has become the dominant mode of energy delivery. Currently, a major limitation of RF ablation is the small lesion size created by this technique that has reduced its success rate in ablation of larger arrhythmogenic substrates such as coronary artery disease-related ventricular tachycardia. Alternate energy sources such as microwave or ultrasound catheter ablation are being developed that have the potential for producing larger lesions than RF ablation. This review will discuss the biophysics and pathophysiology of the various energy modalities used in catheter ablation.

  20. Medical catheters thermally manipulated by fiber optic bundles

    DOEpatents

    Chastagner, Philippe

    1992-01-01

    A maneuverable medical catheter comprising a flexible tube having a functional tip. The catheter is connected to a control source. The functional tip of the catheter carries a plurality of temperature activated elements arranged in parallel and disposed about the functional tip and held in spaced relation at each end. These elements expand when they are heated. A plurality of fiber optic bundles, each bundle having a proximal end attached to the control source and a distal end attached to one of the elements carry light into the elements where the light is absorbed as heat. By varying the optic fiber that is carrying the light and the intensity of the light, the bending of the elements can be controlled and thus the catheter steered. In an alternate embodiment, the catheter carries a medical instrument for gathering a sample of tissue. The instrument may also be deployed and operated by thermal expansion and contraction of its moving parts.

  1. Innovating urinary catheter design: An introduction to the engineering challenge.

    PubMed

    Murphy, Cathy

    2018-05-01

    Every day, people around the world rely on intermittent and indwelling urinary catheters to manage bladder dysfunction, but the potential or actual harm caused by these devices is well-recognised. Current catheter designs can cause urinary tract infection and septicaemia, bladder and urethral trauma and indwelling devices frequently become blocked. Furthermore, the devices can severely disrupt users' lives, limiting their daily activities and can be costly to manage for healthcare providers. Despite this, little significant design innovation has taken place in the last 80 years. In this article current catheter designs and their limitations are reviewed, common catheter-associated problems are outlined and areas of design ripe for improvement proposed. The potential to relieve the individual and economic burden of catheter use is high.

  2. An Effective Technique for Enhancing an Intrauterine Catheter Fetal Electrocardiogram

    NASA Astrophysics Data System (ADS)

    Horner, Steven L.; Holls, William M.

    2003-12-01

    Physician can obtain fetal heart rate, electrophysiological information, and uterine contraction activity for determining fetal status from an intrauterine catheters electrocardiogram with the maternal electrocardiogram canceled. In addition, the intrauterine catheter would allow physicians to acquire fetal status with one non-invasive to the fetus biosensor as compared to invasive to the fetus scalp electrode and intrauterine pressure catheter used currently. A real-time maternal electrocardiogram cancellation technique of the intrauterine catheters electrocardiogram will be discussed along with an analysis for the methods effectiveness with synthesized and clinical data. The positive results from an original detailed subjective and objective analysis of synthesized and clinical data clearly indicate that the maternal electrocardiogram cancellation method was found to be effective. The resulting intrauterine catheters electrocardiogram from effectively canceling the maternal electrocardiogram could be used for determining fetal heart rate, fetal electrocardiogram electrophysiological information, and uterine contraction activity.

  3. Investigations of the pushability behavior of cardiovascular angiographic catheters.

    PubMed

    Bloss, Peter; Rothe, Wolfgang; Wünsche, Peter; Werner, Christian; Rothe, Alexander; Kneissl, Georg Dieter; Burger, Wolfram; Rehberg, Elisabeth

    2003-01-01

    The placement of angiographic catheters into the vascular system is a routine procedure in modern clinical business. The definition of objective but not yet available evaluation protocols based on measurable physical quantities correlated to the empirical clinical findings is of utmost importance for catheter manufacturers for in-house product screening and optimization. In this context, we present an assessment of multiple mechanical and surface catheter properties such as static and kinetic friction, bending stiffness, microscopic surface topology, surface roughness, surface free energy and their interrelation. Theoretical framework, description of experimental methods and extensive data measured on several different catheters are provided and in conclusion a testing procedure is defined. Although this procedure is based on the measurement of several physical quantities it can be easily implemented by commercial laboratories testing catheters as it is based on relatively low-cost standard methods.

  4. Positioning of nasobiliary tube using magnet-loaded catheters.

    PubMed

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Medical catheters thermally manipulated by fiber optic bundles

    DOEpatents

    Chastagner, P.

    1992-10-06

    A maneuverable medical catheter comprising a flexible tube having a functional tip is described. The catheter is connected to a control source. The functional tip of the catheter carries a plurality of temperature activated elements arranged in parallel and disposed about the functional tip and held in spaced relation at each end. These elements expand when they are heated. A plurality of fiber optic bundles, each bundle having a proximal end attached to the control source and a distal end attached to one of the elements carry light into the elements where the light is absorbed as heat. By varying the optic fiber that is carrying the light and the intensity of the light, the bending of the elements can be controlled and thus the catheter steered. In an alternate embodiment, the catheter carries a medical instrument for gathering a sample of tissue. The instrument may also be deployed and operated by thermal expansion and contraction of its moving parts. 10 figs.

  6. The Development for Polymer Actuator Active Catheter System

    PubMed Central

    Sewa, S.; Onishi, K.; Oguro, K.; Asaka, K.; Taki, W.; Toma, N.

    2001-01-01

    Summary Electric stimuli polymer-metal composite actuator material has been developed for active catheter system and other widely new applications. The polymer actuator is made of ion exchange polymer and gold as electrode, and a pulse voltage of 3 volts on the actuator gave a quick bend 90 degree angle. This composite material is possible to make small size, light and soft actuator. So now we can actually develop an active catheter for the interventional radiology surgery. The prototype polymer actuator active catheter has been developed by using polymer actuator technology and Micro Electronics Mechanical System (MEMS) technologies. The active catheter is controllable from the outside of the body by electric signal. The tip part of the catheter is made of the polymer actuator tube and bends 90 degree angles. The animal tests (dog) showed good actuator performance to control right direction and bending angle at bifurcation of blood vessel and aneurysms. PMID:20663388

  7. Peritoneal dialysis catheter implantation: avoiding problems and optimizing outcomes.

    PubMed

    Crabtree, John H

    2015-01-01

    The success of peritoneal dialysis (PD) as renal replacement therapy is dependent upon the patient having a functional long-term peritoneal access. There are a number of identified best practices that must be adhered to during PD catheter placement to achieve a durable and infection-resistant access. The clinical setting, available resources, and the employed catheter insertion method may not always permit complete adherence to these practices; however, an attempt should be made to comply with them as closely as possible. Although omission of any one of the practices can lead to catheter loss, departures from some are committed more frequently, manifesting as commonly occurring clinical problems, such as drain pain, catheter tip migration, omental entrapment, pericatheter leaks and hernias, and poor exit-site location. Understanding the technical pitfalls in PD catheter placement that lead to these problems, enable the provider to modify practice habits to avoid them and optimize outcomes. © 2014 Wiley Periodicals, Inc.

  8. Urethral catheter insertion forces: a comparison of experience and training.

    PubMed

    Canales, Benjamin K; Weiland, Derek; Reardon, Scott; Monga, Manoj

    2009-01-01

    This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6) had the lowest average insertion force for any group at 6.8 +/- 2.0 Newtons (N). Medical students (n = 10) had the least amount of experience (1 +/- 0 years) and the highest average insertion force range of 10.1 +/- 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 +/- 1.8 N) compared to all groups (p < 0.01). We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.

  9. Hemodialysis tunneled central venous catheters: five-year outcome analysis.

    PubMed

    Mandolfo, Salvatore; Acconcia, Pasqualina; Bucci, Raffaella; Corradi, Bruno; Farina, Marco; Rizzo, Maria Antonietta; Stucchi, Andrea

    2014-01-01

    Tunneled central venous catheters (tCVCs) are considered inferior to arteriovenous fistulas (AVFs) and grafts in all nephrology guidelines. However, they are being increasingly used as hemodialysis vascular access. The purpose of this study was to document the natural history of tCVCs and determine the rate and type of catheter replacement. This was a prospective study of 141 patients who underwent hemodialysis with tCVCs between January 2008 and December 2012. The patients used 154 tCVCs. Standard protocols about management of tCVCs, according to European Renal Best Practice, were well established. All catheters were inserted in the internal jugular vein. Criteria for catheter removal were persistent bloodstream infection, detection of an outbreak of catheter-related bloodstream (CRBS) infections, or catheter dysfunction. Event rates were calculated per 1,000 catheter days; tCVC cumulative survival was estimated by Kaplan-Meier analysis. Catheter replacement occurred in 15 patients (0.29 per 1,000 days); catheter dysfunction was the main cause of replacement (0.18 per 1,000 days), typically within 12 months of surgical insertion. A total of 53 CRBS events in 36 patients were identified (0.82 per 1,000 days); 17 organisms, most commonly Gram-positive pathogens, were isolated; 87% of CVC infections were treated by systemic antibiotics associated with lock therapy. tCVC cumulative survival was 91% at 1 year, 88% at 2 years and 85% at 4 years. Our data show a high survival rate of tCVCs in hemodialysis patients, with low incidence of catheter dysfunction and CRBS events. These data justify tCVC use for hemodialysis vascular access, also as first choice, especially in patients with exhausted peripheral access and limited life expectancy.

  10. Explosive plane-wave lens

    DOEpatents

    Marsh, S.P.

    1987-03-12

    An explosive plane-wave air lens which enables a spherical wave form to be converted to a planar wave without the need to specially machine or shape explosive materials is described. A disc-shaped impactor having a greater thickness at its center than around its periphery is used to convert the spherical wave into a plane wave. When the wave reaches the impactor, the center of the impactor moves first because the spherical wave reaches the center of the impactor first. The wave strikes the impactor later in time as one moves radially along the impactor. Because the impactor is thinner as one moves radially outward, the velocity of the impactor is greater at the periphery than at the center. An acceptor explosive is positioned so that the impactor strikes the acceptor simultaneously. Consequently, a plane detonation wave is propagated through the acceptor explosive. 3 figs., 3 tabs.

  11. Explosive plane-wave lens

    DOEpatents

    Marsh, S.P.

    1988-03-08

    An explosive plane-wave air lens which enables a spherical wave form to be converted to a planar wave without the need to specially machine or shape explosive materials is described. A disc-shaped impactor having a greater thickness at its center than around its periphery is used to convert the spherical wave into a plane wave. When the wave reaches the impactor, the center of the impactor moves first because the spherical wave reaches the center of the impactor first. The wave strikes the impactor later in time as one moves radially along the impactor. Because the impactor is thinner as one moves radially outward, the velocity of the impactor is greater at the periphery than at the center. An acceptor explosive is positioned so that the impactor strikes the acceptor simultaneously. Consequently, a plane detonation wave is propagated through the acceptor explosive. 4 figs.

  12. Explosive plane-wave lens

    DOEpatents

    Marsh, Stanley P.

    1988-01-01

    An explosive plane-wave air lens which enables a spherical wave form to be converted to a planar wave without the need to specially machine or shape explosive materials is described. A disc-shaped impactor having a greater thickness at its center than around its periphery is used to convert the spherical wave into a plane wave. When the wave reaches the impactor, the center of the impactor moves first because the spherical wave reaches the center of the impactor first. The wave strikes the impactor later in time as one moves radially along the impactor. Because the impactor is thinner as one moves radially outward, the velocity of the impactor is greater at the periphery than at the center. An acceptor explosive is positioned so that the impactor strikes the acceptor simultaneously. Consequently, a plane detonation wave is propagated through the acceptor explosive.

  13. A statistical model of catheter motion from interventional x-ray images: application to image-based gating

    NASA Astrophysics Data System (ADS)

    Panayiotou, M.; King, A. P.; Ma, Y.; Housden, R. J.; Rinaldi, C. A.; Gill, J.; Cooklin, M.; O'Neill, M.; Rhode, K. S.

    2013-11-01

    The motion and deformation of catheters that lie inside cardiac structures can provide valuable information about the motion of the heart. In this paper we describe the formation of a novel statistical model of the motion of a coronary sinus (CS) catheter based on principal component analysis of tracked electrode locations from standard mono-plane x-ray fluoroscopy images. We demonstrate the application of our model for the purposes of retrospective cardiac and respiratory gating of x-ray fluoroscopy images in normal dose x-ray fluoroscopy images, and demonstrate how a modification of the technique allows application to very low dose scenarios. We validated our method on ten mono-plane imaging sequences comprising a total of 610 frames from ten different patients undergoing radiofrequency ablation for the treatment of atrial fibrillation. For normal dose images we established systole, end-inspiration and end-expiration gating with success rates of 100%, 92.1% and 86.9%, respectively. For very low dose applications, the method was tested on the same ten mono-plane x-ray fluoroscopy sequences without noise and with added noise at signal to noise ratio (SNR) values of √50, √10, √8, √6, √5, √2 and √1 to simulate the image quality of increasingly lower dose x-ray images. The method was able to detect the CS catheter even in the lowest SNR images with median errors not exceeding 2.6 mm per electrode. Furthermore, gating success rates of 100%, 71.4% and 85.7% were achieved at the low SNR value of √2, representing a dose reduction of more than 25 times. Thus, the technique has the potential to extract useful information whilst substantially reducing the radiation exposure.

  14. Comparing the effectiveness of ropivacaine 0.5% versus ropivacaine 0.2% for transabdominis plane block in providing postoperative analgesia after appendectomy.

    PubMed

    Abdul Jalil, Reymi Marseela; Yahya, Nurlia; Sulaiman, Omar; Wan Mat, Wan Rahiza; Teo, Rufinah; Izaham, Azarinah; Rahman, Raha Abdul

    2014-06-01

    The basis for the transversus abdominis plane (TAP) block involves infiltration of a local anesthetic into the neurofascial plane between the internal oblique and the transversus abdominis muscles, causing a regional block that spreads between the L1 and T10 dermatomes. Thus, the TAP block is said to be suitable for lower abdominal surgery. This study was designed to compare the analgesic efficacy of two different concentrations of ropivacaine for TAP block in patients undergoing appendectomy. Fifty-six patients with American Society of Anesthesiologists physical status I or II, aged 18 years and above, undergoing appendectomy were recruited in this prospective, randomized, double-blind study. They were divided into two groups: Group A patients who received 0.5 mL/kg of ropivacaine 0.5% and Group B patients who received 0.5 mL/kg of ropivacaine 0.2% via TAP block under ultrasound guidance. Postoperative pain was assessed using the visual analog scale upon arrival at the recovery room in the operating theatre, just prior to being discharged to the ward, and at 6 hours, 12 hours, 18 hours, and 24 hours postoperatively to compare the effectiveness of analgesia. Intraoperatively, patients in Group B required a significantly greater amount of additional intravenous fentanyl than those in Group A. There were no significant statistical differences in pain scores at rest and on movement at all assessment times as well as in the dose of 24-hour intravenous morphine consumption given via patient-controlled analgesia postoperatively between the two groups. The effectiveness of two different concentrations of ropivacaine (0.5% versus 0.2%) given via TAP block was comparable in providing postoperative analgesia for patients undergoing appendectomy. Copyright © 2014. Published by Elsevier B.V.

  15. Space-Plane Spreadsheet Program

    NASA Technical Reports Server (NTRS)

    Mackall, Dale

    1993-01-01

    Basic Hypersonic Data and Equations (HYPERDATA) spreadsheet computer program provides data gained from three analyses of performance of space plane. Equations used to perform analyses derived from Newton's second law of physics, derivation included. First analysis is parametric study of some basic factors affecting ability of space plane to reach orbit. Second includes calculation of thickness of spherical fuel tank. Third produces ratio between volume of fuel and total mass for each of various aircraft. HYPERDATA intended for use on Macintosh(R) series computers running Microsoft Excel 3.0.

  16. Evaluation of urinary catheters coated with sustained-release varnish of chlorhexidine in mitigating biofilm formation on urinary catheters in dogs.

    PubMed

    Segev, G; Bankirer, T; Steinberg, D; Duvdevani, M; Shapur, N K; Friedman, M; Lavy, E

    2013-01-01

    Biofilm formation occurs commonly on urinary catheters. To assess the efficacy of urinary catheters coated with sustained-release varnish of chlorhexidine in decreasing catheter-associated biofilm formation in dogs. Thirty client-owned dogs. Prospective study. Thirteen dogs were catheterized with urinary catheters coated with sustained-release varnish of chlorhexidine (study group), and 13 dogs were catheterized with an untreated urinary catheter (control group). Presence and intensity of biofilm formation on the urinary catheters were assessed and compared between the groups by evaluating colony-forming units (CFU) of biofilm bacteria, and semiquantitatively, using confocal laser scanning microscopy and electron microscopy. None of the dogs experienced adverse effects associated with the presence of the urinary catheters. Median CFU count of biofilm bacteria at all portions of the urinary catheter was significantly (P < .001) lower in the study compared with the control group. The degree of biofilm formation on the urinary catheters, as evaluated by confocal laser scanning microscopy and electron microscopy, was significantly lower in the study compared with the control group. Electron microscopy examination identified crystals on some of the urinary catheters. The proportion of catheters on which crystals were observed was significantly lower on the distal part of the urinary catheter in the study group compared with the control group (16.7% versus 66.7%, respectively; P = .04). Chlorhexidine sustained-release varnish-coated urinary catheters effectively decrease urinary catheter-associated biofilm formation in dogs. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  17. Innovations in Balloon Catheter Technology in Rhinology.

    PubMed

    D'Anza, Brian; Sindwani, Raj; Woodard, Troy D

    2017-06-01

    Since being introduced more than 10 years ago, balloon catheter technology (BCT) has undergone several generations of innovations. From construction to utilization, there has been a myriad of advancements in balloon technology. The ergonomics of the balloon dilation systems have improved with a focus on limiting the extra assembly. "Hybrid" BCT procedures have shown promise in mucosal preservation, including treating isolated complex frontal disease. Multiple randomized clinical trials report improved long-term outcomes in stand-alone BCT, including in-office use. The ever-expanding technological innovations ensure BCT will be a key component in the armamentarium of the modern sinus surgeon. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Distributed parameter statics of magnetic catheters.

    PubMed

    Tunay, Ilker

    2011-01-01

    We discuss how to use special Cosserat rod theory for deriving distributed-parameter static equilibrium equations of magnetic catheters. These medical devices are used for minimally-invasive diagnostic and therapeutic procedures and can be operated remotely or controlled by automated algorithms. The magnetic material can be lumped in rigid segments or distributed in flexible segments. The position vector of the cross-section centroid and quaternion representation of an orthonormal triad are selected as DOF. The strain energy for transversely isotropic, hyperelastic rods is augmented with the mechanical potential energy of the magnetic field and a penalty term to enforce the quaternion unity constraint. Numerical solution is found by 1D finite elements. Material properties of polymer tubes in extension, bending and twist are determined by mechanical and magnetic experiments. Software experiments with commercial FEM software indicate that the computational effort with the proposed method is at least one order of magnitude less than standard 3D FEM.

  19. The effects of electric current on bacteria colonising intravenous catheters.

    PubMed

    Liu, W K; Tebbs, S E; Byrne, P O; Elliott, T S

    1993-11-01

    The effect of a direct electric current (10 microA) on the growth of Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Klebsiella pneumoniae and Proteus mirabilis was investigated. When the ends of negatively-charged intravascular catheters were placed in nutrient agar seeded with bacteria, circular zones of inhibition of bacterial growth were observed around the catheters. The zones ranged from 6 to 16 mm in diameter according to the organism under test. Zones of inhibition were not produced around positively-charged catheters. Bacteria colonising the surfaces of catheters were similarly affected by the application of a 10 microA electric current. A negative electric current applied to colonised catheters for 4 to 24 h significantly reduced the number of adherent viable organisms as compared to controls. The results demonstrated that a constant electric current of low amperage might be used to reduce bacterial colonisation of intravascular catheters. This may offer a novel means of protecting catheters and other prosthetic devices from associated sepsis in vivo.

  20. Bacteria on catheters in patients undergoing peritoneal dialysis.

    PubMed

    Pihl, Maria; Davies, Julia R; Johansson, Ann-Cathrine; Svensäter, Gunnel

    2013-01-01

    Peritonitis is the leading cause of morbidity for peritoneal dialysis (PD) patients, and microbial biofilms have previously been identified on catheters from infected patients. However, few studies of catheters from patients without clinical signs of infection have been undertaken. The aim of the present study was to investigate the extent to which bacteria are present on catheters from PD patients with no symptoms of infection. Microbiologic culturing under aerobic and anaerobic conditions and confocal laser scanning microscopy were used to determine the distribution of bacteria on PD catheters from 15 patients without clinical signs of infection and on catheters from 2 infected patients. The 16S rRNA gene sequencing technique was used to identify cultured bacteria. Bacteria were detected on 12 of the 15 catheters from patients without signs of infection and on the 2 catheters from infected patients. Single-species and mixed-microbial communities containing up to 5 species were present on both the inside and the outside along the whole length of the colonized catheters. The bacterial species most commonly found were the skin commensals Staphylococcus epidermidis and Propionibacterium acnes, followed by S. warneri and S. lugdunensis. The strains of these micro-organisms, particularly those of S. epidermidis, varied in phenotype with respect to their tolerance of the major classes of antibiotics. Bacteria were common on catheters from patients without symptoms of infection. Up to 4 different bacterial species were found in close association and may represent a risk factor for the future development of peritonitis in patients hosting such micro-organisms.

  1. Videolaparoscopic Catheter Placement Reduces Contraindications to Peritoneal Dialysis

    PubMed Central

    Santarelli, Stefano; Zeiler, Matthias; Monteburini, Tania; Agostinelli, Rosa Maria; Marinelli, Rita; Degano, Giorgio; Ceraudo, Emilio

    2013-01-01

    ♦ Background: Videolaparoscopy is considered the reference method for peritoneal catheter placement in patients with previous abdominal surgery. The placement procedure is usually performed with at least two access sites: one for the catheter and the second for the laparoscope. Here, we describe a new one-port laparoscopic procedure that uses only one abdominal access site in patients not eligible for laparotomic catheter placement. ♦ Method: We carried out one-port laparoscopic placement in 21 patients presenting contraindications to blind surgical procedures because of prior abdominal surgery. This technique consists in the creation of a single mini-laparotomy access through which laparoscopic procedures and placement are performed. The catheter, rectified by an introducer, is inserted inside the port. Subsequently, the port is removed, leaving the catheter in pelvic position. The port is reintroduced laterally to the catheter, confirming or correcting its position. Laparotomic placement was performed in a contemporary group of 32 patients without contraindications to blind placement. Complications and long-term catheter outcome in the two groups were evaluated. ♦ Results: Additional interventions during placement were necessary in 12 patients of the laparoscopy group compared with 5 patients of the laparotomy group (p = 0.002). Laparoscopy documented adhesions in 13 patients, with need for adhesiolysis in 6 patients. Each group had 1 intraoperative complication: leakage in the laparoscopy group, and intestinal perforation in the laparotomy group. During the 2-year follow-up period, laparoscopic revisions had to be performed in 6 patients of the laparoscopy group and in 5 patients of the laparotomy group (p = 0.26). The 1-year catheter survival was similar in both groups. Laparoscopy increased by 40% the number of patients eligible to receive peritoneal dialysis. ♦ Conclusions: Videolaparoscopy placement in patients not eligible for blind surgical

  2. Evaluation of robotic endovascular catheters for arch vessel cannulation.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Hamady, Mohamad S; Cheshire, Nicholas J W

    2011-09-01

    Conventional catheter instability and embolization risk limits the adoption of endovascular therapy in patients with challenging arch anatomy. This study investigated whether arch vessel cannulation can be enhanced by a remotely steerable robotic catheter system. Seventeen clinicians with varying endovascular experience cannulated all arch vessels within two computed tomography-reconstructed pulsatile flow phantoms (bovine type I and type III aortic arches), under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times, catheter tip movements, vessel wall hits, catheter deflection) and qualitative metrics (Imperial College Complex Endovascular Cannulation Scoring Tool [IC3ST]) performance scores were compared. Robotic catheterization techniques resulted in a significant reduction in median carotid artery cannulation times and the median number of catheter tip movements for all vessels. Vessel wall contact with the aortic arch wall was reduced to a median of zero with robotic catheters. During stiff guidewire exchanges, robotic catheters maintained stability with zero deflection, independent of the distance the catheter was introduced into the carotid vessels. Overall IC3ST performance scores (interquartile range) were significantly improved using the robotic system: Type I arch score was 26/35 (20-30.8) vs 33/35 (31-34; P = .001), and type III arch score was 20.5/35 (16.5-28.5) vs 26.5/35 (23.5-28.8; P = .001). Low- and medium-volume interventionalists demonstrated an improvement in performance with robotic cannulation techniques. The high-volume intervention group did not show statistically significant improvement, but cannulation times, movements, and vessel wall hits were significantly reduced. Robotic technology has the potential to reduce the time, risk of embolization and catheter dislodgement, radiation exposure, and the manual skill required for carotid and arch vessel cannulation, while improving overall

  3. Steerable catheter microcoils for interventional MRI reducing resistive heating.

    PubMed

    Bernhardt, Anthony; Wilson, Mark W; Settecase, Fabio; Evans, Leland; Malba, Vincent; Martin, Alastair J; Saeed, Maythem; Roberts, Timothy P L; Arenson, Ronald L; Hetts, Steven W

    2011-03-01

    The aims of this study were to assess resistive heating of microwires used for remote catheter steering in interventional magnetic resonance imaging and to investigate the use of alumina to facilitate heat transfer to saline flowing in the catheter lumen. A microcoil was fabricated using a laser lathe onto polyimide-tipped or alumina-tipped endovascular catheters. In vitro testing was performed on a 1.5-T magnetic resonance system using a vessel phantom, body radiofrequency coil, and steady-state pulse sequence. Resistive heating was measured with water flowing over a polyimide-tip catheter or saline flowing through the lumen of an alumina-tip catheter. Preliminary in vivo testing in porcine common carotid arteries was conducted with normal blood flow or after arterial ligation when current was applied to an alumina-tip catheter for up to 5 minutes. After application of up to 1 W of direct current power, clinically significant temperature increases were noted with the polyimide-tip catheter: 23°C/W at zero flow, 13°C/W at 0.28 cm(3)/s, and 7.9°C/W at 1 cm(3)/s. Using the alumina-tip catheter, the effluent temperature rise using the lowest flow rate (0.12 cm(3)/s) was 2.3°C/W. In vivo testing demonstrated no thermal injury to vessel walls at normal and zero arterial flow. Resistive heating in current carrying wire pairs can be dissipated by saline coolant flowing within the lumen of a catheter tip composed of material that facilitates heat transfer. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  4. High definition urethral pressure profilometry: Evaluating a novel microtip catheter.

    PubMed

    Klünder, Mario; Amend, Bastian; Vaegler, Martin; Kelp, Alexandra; Feuer, Ronny; Sievert, Karl-Dietrich; Stenzl, Arnulf; Sawodny, Oliver; Ederer, Michael

    2016-11-01

    Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI). SUI is a significant medical, social, and economic problem, affecting about 12.5% of the population. A novel microtip catheter was developed for UPP featuring an inclination sensor and higher angular resolution compared to systems in clinical use today. Therewith, the location of each measured pressure sample can be determined and the spatial pressure distribution inside the urethra reconstructed. In order to assess the performance and plausibility of data from the microtip catheter, we compare it to data from a double balloon air charged system. Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, plotted and compared against data from the air-charged catheter. The microtip catheter delivers results in agreement with previous comparisons of microtip and air-charged systems. It additionally provides a new level of detail in the reconstructed UPPs which may lead to new insights into the sphincter mechanism of minipigs. The ability of air-charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novel microtip catheter in combination with a signal reconstruction algorithm delivers plausible data. It offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct location within the anatomical location of the pelvic floor. Neurourol. Urodynam. 35:888-894, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  5. The effect of elastic modulus on ablation catheter contact area.

    PubMed

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  6. Thromboresistance Characterization of Extruded Nitric Oxide-Releasing Silicone Catheters

    PubMed Central

    Amoako, Kagya A.; Archangeli, Christopher; Handa, Hitesh; Major, Terry; Meyerhoff, Mark E.; Annich, Gail M.; Bartlett, Robert H.

    2013-01-01

    Intravascular catheters used in clinical practice can activate platelets, leading to thrombus formation and stagnation of blood flow. Nitric oxide (NO)-releasing polymers have been shown previously to reduce clot formation on a number of blood contacting devices. In this work, trilaminar NO-releasing silicone catheters were fabricated and tested for their thrombogenicity. All catheters had specifications of L = 6 cm, inner diameter = 21 gauge (0.0723 cm), outer diameter = 12 gauge (0.2052 cm), and NO-releasing layer thickness = 200 ± 11 μm. Control and NO-releasing catheters were characterized in vitro for their NO flux and NO release duration by gas phase chemiluminescence measurements. The catheters were then implanted in the right and left internal jugular veins of (N = 6 and average weight = 3 kg) adult male rabbits for 4 hours thrombogenicity testing. Platelet counts and function, methemoglobin (metHb), hemoglobin (Hb), and white cell counts and functional time (defined as patency time of catheter) were monitored as measured outcomes. Nitric oxide-releasing catheters (N = 6) maintained an average flux above (2 ± 0.5) × 10−10 mol/min/cm2 for more than 24 hours, whereas controls showed no NO release. Methemoglobin, Hb, white cell, and platelet counts and platelet function at 4 hours were not significantly different from baseline (α = 0.05). However, clots on controls were visibly larger and prevented blood draws at a significantly (p < 0.05) earlier time (2.3 ± 0.7 hours) into the experiment, whereas all NO-releasing catheters survived the entire 4 hours test period. Results indicate that catheter NO flux levels attenuated thrombus formation in a short-term animal model. PMID:22395119

  7. Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

    PubMed

    Cheng, Weyland; Law, Peter K

    2017-08-01

    Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.

  8. Antibiofilm surface functionalization of catheters by magnesium fluoride nanoparticles

    PubMed Central

    Lellouche, Jonathan; Friedman, Alexandra; Lahmi, Roxanne; Gedanken, Aharon; Banin, Ehud

    2012-01-01

    The ability of bacteria to colonize catheters is a major cause of infection. In the current study, catheters were surface-modified with MgF2 nanoparticles (NPs) using a sonochemical synthesis protocol described previously. The one-step synthesis and coating procedure yielded a homogenous MgF2 NP layer on both the inside and outside of the catheter, as analyzed by high resolution scanning electron microscopy and energy dispersive spectroscopy. The coating thickness varied from approximately 750 nm to 1000 nm on the inner walls and from approximately 450 nm to approximately 580 nm for the outer wall. The coating consisted of spherical MgF2 NPs with an average diameter of approximately 25 nm. These MgF2 NP-modified catheters were investigated for their ability to restrict bacterial biofilm formation. Two bacterial strains most commonly associated with catheter infections, Escherichia coli and Staphylococcus aureus, were cultured in tryptic soy broth, artificial urine and human plasma on the modified catheters. The MgF2 NP-coated catheters were able to significantly reduce bacterial colonization for a period of 1 week compared to the uncoated control. Finally, the potential cytotoxicity of MgF2 NPs was also evaluated using human and mammalian cell lines and no significant reduction in the mitochondrial metabolism was observed. Taken together, our results indicate that the surface modification of catheters with MgF2 NPs can be effective in preventing bacterial colonization and can provide catheters with long-lasting self-sterilizing properties. PMID:22419866

  9. Affine Contractions on the Plane

    ERIC Educational Resources Information Center

    Celik, D.; Ozdemir, Y.; Ureyen, M.

    2007-01-01

    Contractions play a considerable role in the theory of fractals. However, it is not easy to find contractions which are not similitudes. In this study, it is shown by counter examples that an affine transformation of the plane carrying a given triangle onto another triangle may not be a contraction even if it contracts edges, heights or medians.…

  10. Ion beam sputter-etched ventricular catheter for hydrocephalus shunt

    NASA Technical Reports Server (NTRS)

    Banks, B. A. (Inventor)

    1983-01-01

    A cerebrospinal fluid shunt in the form of a ventricular catheter for controlling the condition of hydrocephalus by relieving the excessive cerebrospinal fluid pressure is described. A method for fabrication of the catheter and shunting the cerebral fluid from the cerebral ventricles to other areas of the body is also considered. Shunt flow failure occurs if the ventricle collapse due to improper valve function causing overdrainage. The ventricular catheter comprises a multiplicity of inlet microtubules. Each microtubule has both a large openings at its inlet end and a multiplicity of microscopic openings along its lateral surfaces.

  11. Spiculated Bladder Calculi: The Culprit for Repeated Catheter Failure

    PubMed Central

    Wek, C.; Fox, T. P.; Muir, G. H.

    2013-01-01

    We report on the case of a frustrated 90-year-old gentleman who was seen in the Accident and Emergency department for the third time in four days with failure of his long-term urethral catheter. He reported that the catheter simply “fell out” with the balloon deflated. On each occasion previously, the catheter had been reinserted in A&E and the patient discharged home. These repeated visits to A&E were understandably a source of much frustration for the patient and his family. On the third presentation, plain abdominal radiography demonstrated a large spiculated bladder calculus. PMID:23984173

  12. Changes in Transversus Abdominis Muscle Thickness after Lumbo-Pelvic Core Stabilization Training among Chronic Low Back Pain Individuals.

    PubMed

    Leonard, J H; Paungmali, A; Sitilertpisan, P; Pirunsan, U; Uthaikhup, S

    2015-01-01

    Lumbo-pelvic core stabilization training (LPST) is one of the therapeutic exercises common in practice for rehabilitation of patients with chronic low back pain. This study was carried out to examine the therapeutic effects of LPST on the muscle thickness of transversus abdominis (TrA) at rest and during contraction among patients with chronic non-specific low back pain. A total of 25 participants (7 males and 18 females) with chronic non-specific low back pain participated in a within-subject, repeated measures, double-blinded, placebo-controlled comparisons trial. The participants received three different types of experimental therapeutic training conditions which includes the lumbo-pelvic core stabilization training (LPST), the placebo treatment with passive cycling (PC) and a controlled intervention with rest (CI). The interventions were carried out by randomization with 48 hours between the sessions. The effectiveness of interventions was studied by measuring the changes in muscle thickness of TrA at rest and during contraction using a real time ultrasonography. Repeated measures ANOVA demonstrated that the LPST provided significant therapeutic benefits as measured by an increase in the muscle thickness of the TrA at rest (p<0.05) and during contraction (p<0.01). The percentage change of the muscle thickness observed during LPST was significantly higher (p<0.01) when compared to the other two experimental training conditions. The findings indicated that the LPST might provide therapeutic benefits by increasing the muscle thickness and function of TrA. Therefore, it is suggested that LPST technique should be considered as part of management program for treatment of low back pain.

  13. The Impact of Perioperative Hormonal Therapy for Breast Cancer on Transverse Rectus Abdominis Myocutaneous Flap Abdominal Complications.

    PubMed

    Huber, Katherine M; Clayman, Eric; Kumar, Ambuj; Smith, Paul

    2018-06-01

    The pedicled transverse rectus abdominis myocutaneous (TRAM) flap is a reliable reconstructive option in breast cancer patients; however, it carries known risk of donor site hernia formation. Some hormonal therapy drugs have been associated with hernia formation in animal models. Minimal data exist concerning impact of hormonal therapy for breast cancer on abdominal donor site complications after breast reconstruction. Patients who underwent TRAM flap for breast cancer or high-risk status at a single institution by the senior author from 2003 to 2015 were identified. Charts were reviewed. Patient demographics, comorbidities, treatments, and abdominal complications were recorded. Patients were divided into groups based on use of hormonal therapy as well as exposure to specific drugs. Statistical analyses were performed. A total of 358 patients were included. Overall hernia rate was 5.9%. About 231 (64.5%) patients had hormonal therapy, whereas 127 (35.5%) did not. Difference in hernia formation was not statistically significant between the hormonal therapy group (6.9%) and the no hormonal therapy group (3.9%; P = 0.359). Patients exposed to tamoxifen and those exposed to anastrozole had no significant difference in complication rates compared with the no hormonal therapy group, whereas patients exposed to letrozole had increased rate of hernia (13.5%; P = 0.037) and infection (21.6%; P = 0.013) compared with the no hormonal therapy group (3.9% and 7.1%, respectively). Hormonal therapy is a useful adjunct for chemoprevention in breast cancer; however, use of letrozole in patients undergoing reconstruction with pedicled TRAM can lead to increase in certain complication rates.

  14. Phantom rectal sensations following abdominoperineal excision of the rectum (APER) and vertical rectus abdominis myocutaneous (VRAM) flap perineal reconstruction.

    PubMed

    Gould, Charlotte R; Branagan, Graham

    2016-11-01

    Phantom rectum is the sensation of an intact and/or functioning rectum, despite excision at surgery. Abdominoperineal excision of the rectum (APER) may be complemented by reconstructive operations and recently it was reported that patients undergoing APER and vertical rectus abdominis myocutaneous (VRAM) flap reconstruction are more prone to develop phantom sensations at an earlier timeframe and have more persistent symptoms than those who do not have perineal repairs. The aim of this study was to determine the prevalence of phantom rectal sensations in a cohort of these patients. Patients who underwent APER and VRAM flap reconstruction for anorectal carcinomas were identified from May 2008 to July 2012. Patients completed a questionnaire evaluating their experience of rectal symptoms post-surgery. Thirty-four of 47 eligible patients were enrolled in the study. PR sensations were experienced by 50 % of patients, the majority of which (65 %) were present for >1 year. The commonest sensation reported was the feeling of faeces in a normal rectum (24 %). Disturbances in quality of life were apparent in 44 %; notably, sleep was affected, patients expressed increased feelings of stress/sadness, heightened levels of anxiety and limitation of daily activities as consequences of PR symptoms. Few patients sought medical advice. Fifty percent of patients experience PR sensations post-surgery, comparable with reported data for patients who have undergone APER alone. The addition of VRAM reconstruction does not significantly alter the prevalence of PR symptoms. This paper provides further evidence that phantom rectum occurs frequently and thus all patients undergoing excision of the rectum should be counselled appropriately.

  15. The Deep Inferior Epigastric Perforator and Pedicled Transverse Rectus Abdominis Myocutaneous Flap in Breast Reconstruction: A Comparative Study

    PubMed Central

    Tan, Shane; Yek, Jacklyn; Ong, Wei Chen; Hing, Chor Hoong; Lim, Thiam Chye

    2013-01-01

    Background Our objective was to compare the complication rates of two common breast reconstruction techniques performed at our hospital and the cost-effectiveness for each test group. Methods All patients who underwent deep inferior epigastric perforator (DIEP) flap and transverse rectus abdominis myocutaneous (TRAM) flap by the same surgeon were selected and matched according to age and mastectomy with or without axillary clearance. Patients from each resultant group were selected, with the patients matched chronologically. The remainder were matched for by co-morbidities. Sixteen patients who underwent immediate breast reconstruction with pedicled TRAM flaps and 16 patients with DIEP flaps from 1999 to 2006 were accrued. The average total hospitalisation cost, length of hospitalisation, and complications in the 2 year duration after surgery for each group were compared. Results Complications arising from both the pedicled TRAM flaps and DIEP flaps included fat necrosis (TRAM, 3/16; DIEP, 4/16) and other minor complications (TRAM, 3/16; DIEP, 1/16). The mean hospital stay was 7.13 days (range, 4 to 12 days) for the pedicled TRAM group and 7.56 (range, 5 to 10 days) for the DIEP group. Neither the difference in complication rates nor in hospital stay duration were statistically significant. The total hospitalisation cost for the DIEP group was significantly higher than that of the pedicled TRAM group (P<0.001). Conclusions Based on our study, the pedicled TRAM flap remains a cost-effective technique in breast reconstruction when compared to the newer, more expensive and tedious DIEP flap. PMID:23730591

  16. Effects of exercise on diastasis of the rectus abdominis muscle in the antenatal and postnatal periods: a systematic review.

    PubMed

    Benjamin, D R; van de Water, A T M; Peiris, C L

    2014-03-01

    Diastasis of the rectus abdominis muscle (DRAM) is common during and after pregnancy, and has been related to lumbopelvic instability and pelvic floor weakness. Women with DRAM are commonly referred to physiotherapists for conservative management, but little is known about the effectiveness of such strategies. To determine if non-surgical interventions (such as exercise) prevent or reduce DRAM. EMBASE, Medline, CINAHL, PUBMED, AMED and PEDro were searched. Studies of all designs that included any non-surgical interventions to manage DRAM during the ante- and postnatal periods were included. Methodological quality was assessed using a modified Downs and Black checklist. Meta-analysis was performed using a fixed effects model to calculate risk ratios (RR) and 95% confidence intervals (CI) where appropriate. Eight studies totalling 336 women during the ante- and/or postnatal period were included. The study design ranged from case study to randomised controlled trial. All interventions included some form of exercise, mainly targeted abdominal/core strengthening. The available evidence showed that exercise during the antenatal period reduced the presence of DRAM by 35% (RR 0.65, 95% CI 0.46 to 0.92), and suggested that DRAM width may be reduced by exercising during the ante- and postnatal periods. The papers reviewed were of poor quality as there is very little high-quality literature on the subject. Based on the available evidence and quality of this evidence, non-specific exercise may or may not help to prevent or reduce DRAM during the ante- and postnatal periods. Copyright © 2013 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  17. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    PubMed

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  18. Do pulmonary artery catheters cause or increase tricuspid or pulmonic valvular regurgitation?

    PubMed

    Sherman, S V; Wall, M H; Kennedy, D J; Brooker, R F; Butterworth, J

    2001-05-01

    There are few quantitative data on the extent or mechanism of pulmonary artery catheter (PAC)-induced valvular dysfunction. We hypothesized that PACs cause or worsen tricuspid and pulmonic valvular regurgitation, and tested this hypothesis by using transesophageal echocardiography. In 54 anesthetized adult patients, we measured color Doppler jet areas of tricuspid regurgitation (TR) in two planes (midesophageal [ME] 4-chamber and right ventricular inflow-outflow views) and pulmonic insufficiency (PI) in one plane (ME aortic valve long-axis view), both before and after we advanced a PAC into the pulmonary artery. Regurgitant jet areas and hemodynamic measurements were compared by using paired t-test. There were no significant changes in blood pressure or heart rate after passage of the PAC. After PAC placement, the mean PI jet area was not significantly increased. The mean TR jet area increased significantly in the right ventricular inflow-outflow view (+0.37 +/- 0.11 cm(2)) (P = 0.0014), but did not increase at the ME 4-chamber view. Seventeen percent of patients had an increase in TR jet area > or =1 cm(2); 8% of patients had an increase in PI jet area >/=1 cm(2). In patients without pulmonic or tricuspid valvular pathology, placement of a pulmonary artery catheter (PAC) worsened tricuspid regurgitation, which is consistently visualized in the right ventricular inflow-outflow view, and often not seen in the midesophageal 4-chamber view. This is consistent with malcoaptation of the anterior and posterior leaflets. PAC-induced pulmonic insufficiency was rarely detected in the midesophageal aortic valve long-axis view. We conclude that a PAC is very unlikely to be the sole cause of severe tricuspid regurgitation or pulmonic insufficiency.

  19. Catheter-related sepsis due to Rhodotorula glutinis.

    PubMed

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-02-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 microg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns.

  20. Catheter-Related Sepsis Due to Rhodotorula glutinis

    PubMed Central

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  1. Review of advanced catheter technologies in radiation oncology brachytherapy procedures

    PubMed Central

    Zhou, Jun; Zamdborg, Leonid; Sebastian, Evelyn

    2015-01-01

    The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy procedures using magnetic resonance images and electromagnetic tracking. The accuracy of catheter reconstruction, imaging artifacts, and other notable properties of plastic and titanium applicators in gynecologic treatments are reviewed. The accuracy, noise performance, and limitations of electromagnetic tracking for catheter reconstruction are discussed. Several newly developed applicators for accelerated partial breast irradiation and gynecologic treatments are also reviewed. New hypofractionated high dose rate treatment schemes in prostate cancer and accelerated partial breast irradiation are presented. PMID:26203277

  2. Hemodialysis Catheters: How to Keep Yours Working Well

    MedlinePlus

    ... Catheters have two openings inside; one is a red (arterial) opening to draw blood from your vein and out of your body into the dialysis pathway and the other is a blue (venous) opening that allows cleaned blood to return ...

  3. Catheter-Associated Rhodotorula mucilaginosa Fungemia in an Immunocompetent Host

    PubMed Central

    Kim, Hyun Ah; Hyun, Miri

    2013-01-01

    Rhodotorula species live in the environment, but can also colonize human epithelium, as well as respiratory, and gastrointestinal tracts. Reports of infection, especially in the past 2 decades, have noted increasing numbers of Rhodotorula infections, particularly in immunocompromised hosts, leading it to be considered emerging opportunistic pathogen. The major risk factors for infection were prolonged use of central venous catheters in patients with hematological and solid malignancies who are taking corticosteroids or cytotoxic drugs. Herein, we report a case of catheter-associated fungemia due to R. mucilaginosa in an immunocompetent host. The patient was admitted to the intensive care unit with mechanical ventilation for treatment of community-acquired pneumonia. After 10 days, the patient developed new-onset fever confirmed to be a result of catheter-associated blood-stream infection by R. mucilaginosa. It was successfully treated by catheter removal and intravenous amphotericin B. PMID:24396637

  4. Type IIB Colliding Plane Waves

    NASA Astrophysics Data System (ADS)

    Gutperle, M.; Pioline, B.

    2003-09-01

    Four-dimensional colliding plane wave (CPW) solutions have played an important role in understanding the classical non-linearities of Einstein's equations. In this note, we investigate CPW solutions in 2n+2-dimensional Einstein gravity with a n+1-form flux. By using an isomorphism with the four-dimensional problem, we construct exact solutions analogous to the Szekeres vacuum solution in four dimensions. The higher-dimensional versions of the Khan-Penrose and Bell-Szekeres CPW solutions are studied perturbatively in the vicinity of the light-cone. We find that under small perturbations, a curvature singularity is generically produced, leading to both space-like and time-like singularities. For n = 4, our results pertain to the collision of two ten-dimensional type-IIB Blau-Figueroa o'Farrill-Hull-Papadopoulos plane waves.

  5. A simple device for exteriorizing chronically implanted catheters in dogs.

    PubMed

    Butterfield, J L; Decker, G E

    1984-04-01

    A device, consisting of a round base and cap made of polytetrafluoroethylene, was made to exteriorize and protect chronically implanted arterial and venous catheters in conscious dogs. In experiments lasting as long as 9 months, the subcutaneously implanted button-like appliance did not cause tissue reactions and was well tolerated by 98% of a group of 200 dogs. Being maintenance-free, having the capacity to exteriorize several catheter or wire outputs, and needing no protective harness were advantages of the device.

  6. [Tension haemothorax after removal of pleural pigtail catheter].

    PubMed

    Siegel, Hanna; Lauritsen, Anne Øberg

    2014-07-07

    Today, standard treatment of pleural effusion is ultrasound guided insertion of a pleural pigtail catheter. This procedure is known to have a low complication rate, but complications as pneumothorax, haemorrhage and infection are occurring. The most frequent complications are seen at the time of insertion. We present a case of a 68-year-old woman in the intensive care unit with normal coagulation status who after an uneventful removal of a pleural pigtail catheter developed a tension haemothorax requiring acute evacuation.

  7. False coronary dissection with the new Monorail angioplasty balloon catheter.

    PubMed

    Esplugas, E; Cequier, A R; Sabaté, X; Jara, F

    1990-01-01

    During percutaneous transluminal coronary angioplasty, the appearance of persistent staining in the vessel by contrast media suggests coronary dissection. We report seven patients in whom a false image of severe coronary dissection was observed during angioplasty performed with the new Monorail balloon catheter. This image emerges at the moment of balloon inflation, is distally located to the balloon, and disappears with balloon catheter deflation. No complications were associated with the appearance of this image.

  8. Passage through the Ring Plane

    NASA Image and Video Library

    2004-06-03

    The path that lies ahead for the Cassini-Huygens mission is indicated in this image which illustrates where the spacecraft will be just 27 days from now, when it arrives at Saturn and crosses the ring plane 33 minutes before performing its critical orbital insertion maneuver. The X indicates the point where Cassini will pierce the ring plane on June 30, 2004, going from south to north of the ring plane, 33 minutes before the main engine fires to begin orbital insertion. The indicated point is between the narrow F-ring on the left and Saturn's tenuous G-ring which is too faint to be seen in this exposure. The image was taken on May 11, 2004 when the spacecraft was 26.3 million kilometers (16.3 million miles) from Saturn. Image scale is 158 kilometers (98 miles) per pixel. Moons visible in this image: Janus (181 kilometers or 113 miles across), one of the co-orbital moons; Pandora (84 kilometers or 52 miles across), one of the F ring shepherding moons; and Enceladus (499 kilometers or 310 miles across), a moon which may be heated from within and thus have a liquid sub-surface ocean. http://photojournal.jpl.nasa.gov/catalog/PIA06061

  9. Orbital Space Plane (OSP) Program

    NASA Technical Reports Server (NTRS)

    McKenzie, Patrick M.

    2003-01-01

    Lockheed Martin has been an active participant in NASA's Space Launch Initiative (SLI) programs over the past several years. SLI, part of NASA's Integrated Space Transportation Plan (ISTP), was restructured in November of 2002 to focus the overall theme of safer, more afford-able space transportation along two paths - the Orbital Space Plane Program and the Next Generation Launch Technology programs. The Orbital Space Plane Program has the goal of providing rescue capability from the International Space Station by 2008 and transfer capability for crew (and limited cargo) by 2012. The Next Generation Launch Technology program is combining research and development efforts from the 2nd Generation Reusable Launch Vehicle (2GRLV) program with cutting-edge, advanced space transportation programs (previously designated 3rd Generation) into one program aimed at enabling safe, reliable, cost-effective reusable launch systems by the middle of the next decade. Lockheed Martin is one of three prime contractors working to bring Orbital Space Plane system concepts to a system definition level of maturity by December of 2003. This paper and presentation will update the international community on the progress of the' OSP program, from an industry perspective, and provide insights into Lockheed Martin's role in enabling the vision of a safer, more affordable means of taking people to and from space.

  10. Complete resection of a rectus abdominis muscle invaded by desmoid tumors and subsequent management with an abdominal binder: a case report.

    PubMed

    Ogawa, Tatsuhiko

    2018-02-07

    Desmoid-type fibromatosis is characterized by desmoid tumors, which are benign soft tissue tumors that can be locally aggressive but typically do not metastasize. Desmoid tumors can manifest anywhere in the body, and those in the abdominal cavity account for approximately 30 to 50% of all such tumors. Complete resection with free margins has been the standard treatment, but non-surgical therapies have been implemented recently. However, if tumors are strongly invasive and/or persistently recur, radical surgical resection with free margins remains the primary treatment. Unfortunately, radical resection may cause large abdominal defects and hinder reconstruction. Several reports and recommendations have addressed this issue; however, to the best of our knowledge, few reports have described complete resection and the subsequent reconstruction of the rectus abdominis muscle. A 35-year-old Asian woman presented at our hospital with a chief complaint of abdominal pain. She had abdominal desmoid tumors that required complete resection of her rectus abdominis muscle. Due to necrosis in her own reconstructed tissue, we failed to cover her anterior abdominal wall; thus, we used an abdominal binder as a substitute material to avoid exacerbating the incisional hernia and help her generate intra-abdominal pressure. This case report may be informative and helpful for the treatment of patients with desmoid tumors, as managing desmoid-type fibromatosis is difficult.

  11. Rehabilitation and Return to Sport Following Surgical Repair of the Rectus Abdominis and Adductor Longus in a Professional Basketball Player: A Case Report.

    PubMed

    Short, Steven M; Anloague, Philip A; Strack, Donald S

    2016-08-01

    Study Design Case report. Background Acute traumatic avulsion of the rectus abdominis and adductor longus is rare. Chronic groin injuries, often falling under the athletic pubalgia spectrum, have been reported to be more common. There is limited evidence detailing the comprehensive rehabilitation and return to sport of an athlete following surgical or conservative treatment of avulsion injuries of the pubis or other sports-related groin pathologies. Case Description A 29-year-old National Basketball Association player sustained a contact injury during a professional basketball game. This case report describes a unique clinical situation specific to professional sport, in which a surgical repair of an avulsed rectus abdominis and adductor longus was combined with a multimodal impairment- and outcomes-based rehabilitation program. Outcomes The patient returned to in-season competition at 5 weeks postoperation. Objective measures were tracked throughout rehabilitation and compared to baseline assessments. Measures such as the Copenhagen Hip and Groin Outcome Score and numeric pain-rating scale revealed progress beyond the minimal important difference. Discussion This case report details the clinical reasoning and evidence-informed interventions involved in the return to elite sport. Detailed programming and objective assessment may assist in achieving desired outcomes ahead of previously established timelines. Level of Evidence Therapy, level 4. J Orthop Sports Phys Ther 2016;46(8):697-706. Epub 3 Jul 2016. doi:10.2519/jospt.2016.6352.

  12. The effects of bridge exercise on an unstable base of support on lumbar stability and the thickness of the transversus abdominis.

    PubMed

    Cho, Misuk; Jeon, Hyewon

    2013-06-01

    [Purpose] We examined the effects of an abdominal drawing-in bridge exercise using a pressure biofeedback unit on different bases on the thickness of trunk and abdominal muscles, and lumbar stability. [Subjects] Thirty healthy young adults (2 males, 28 females) took part in this study. The subjects were randomly and equally assigned to a stable bridge exercise group and an unstable bridge exercise group. [Methods] The subjects performed bridge exercises using an abdominal drawing-in method on a stable base and on an unstable base, and changes in their abdominal muscle thickness and on the stable and on unstable bases lumbar stability were evaluated. [Results] After the intervention, the stable bridge exercise group showed a statistically significantly increased muscle thickness in the transversus abdominis, and the unstable bridge exercise group showed significantly increased muscle thicknesses of the transversus abdominis and internal obliques in static and dynamic lumbar stability. The unstable bridge exercise group showed significant increase after performing the exercise. [Conclusion] Lumbar stability exercise, with the compensation of the lumbar spine minimized, using an abdominal drawing-in method on an unstable support of base is effective and efforts to prevent the compensation may induce a greater exercise effect.

  13. [Disposable nursing applicator-pocket of indwelling central venous catheter].

    PubMed

    Wei, Congli; Ma, Chunyuan

    2017-11-01

    Catheter related infection is the most common complication of central venous catheter, which pathogen mainly originate from the pipe joint and the skin around puncture site. How to prevent catheter infection is an important issue in clinical nursing. The utility model disclosed a "disposable nursing applicator-pocket of indwelling central venous catheter", which is mainly used for the fixation and the protection. The main structure consists of two parts, one is medical applicator to protect the skin around puncture site, and the other is gauze pocket to protect the catheter external connector. When in use, the catheter connector is fitted into the pocket, and then the applicator is applied to cover the puncture point of the skin. Integrated design of medical applicator and gauze pocket was designed to realize double functions of fixation and protection. The disposable nursing applicator-pocket is made of medical absorbent gauze (outer layer) and non-woven fabric (inner layer), which has the characteristics of comfortable, breathable, dust filtered, bacteria filtered, waterproof, antiperspirant and anti-pollution. The utility model has the advantages of simple structure, low cost, simple operation, effective protection, easy realization and popularization.

  14. The dangers of long-term catheter drainage.

    PubMed

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  15. Intracranial placement of a new, compliant guide catheter: technical note.

    PubMed

    Park, Min S; Stiefel, Michael F; Fiorella, David; Kelly, Michael; McDougall, Cameron G; Albuquerque, Felipe C

    2008-09-01

    We describe our initial experience with the use of a novel, compliant guide catheter designed for placement within the cranial vasculature in a series of seven patients who were treated for various intracranial pathologies. Seven patients were deemed to have either tortuous supra-aortic, intracranial, and/or extracranial vasculature or to require additional microcatheter support as the result of lesion location. The patients were treated, in part, with the 6-French Neuron delivery catheter (Penumbra, Inc., San Leandro, CA) at the authors' two institutions. The guide catheter was positioned in various distal locations within the intracranial internal carotid artery or external carotid artery. Three patients were treated for unruptured intracranial aneurysms, 2 patients for intracranial atherosclerosis, 1 patient for an arteriovenous malformation, and 1 patient for a pseudoaneurysm. All lesions were successfully treated through a microcatheter advanced in a coaxial fashion through the guide catheter. There were no complications related to the positioning of the catheter. Distal intra- or extracranial placement of a specially designed, compliant guide catheter can be performed safely and may improve access and microcatheter stability in patients with tortuous vessels or difficult-to-reach lesions.

  16. Post-procedural evaluation of catheter contact force characteristics

    NASA Astrophysics Data System (ADS)

    Koch, Martin; Brost, Alexander; Kiraly, Atilla; Strobel, Norbert; Hornegger, Joachim

    2012-03-01

    Minimally invasive catheter ablation of electric foci, performed in electrophysiology labs, is an attractive treatment option for atrial fibrillation (AF) - in particular if drug therapy is no longer effective or tolerated. There are different strategies to eliminate the electric foci inducing the arrhythmia. Independent of the particular strategy, it is essential to place transmural lesions. The impact of catheter contact force on the generated lesion quality has been investigated recently, and first results are promising. There are different approaches to measure catheter-tissue contact. Besides traditional haptic feedback, there are new technologies either relying on catheter tip-to-tissue contact force or on local impedance measurements at the tip of the catheter. In this paper, we present a novel tool for post-procedural ablation point evaluation and visualization of contact force characteristics. Our method is based on localizing ablation points set during AF ablation procedures. The 3-D point positions are stored together with lesion specific catheter contact force (CF) values recorded during the ablation. The force records are mapped to the spatial 3-D positions, where the energy has been applied. The tracked positions of the ablation points can be further used to generate a 3-D mesh model of the left atrium (LA). Since our approach facilitates visualization of different force characteristics for post-procedural evaluation and verification, it has the potential to improve outcome by highlighting areas where lesion quality may be less than desired.

  17. Cryo-balloon catheter localization in fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  18. New materials and devices for preventing catheter-related infections

    PubMed Central

    2011-01-01

    Catheters are the leading source of bloodstream infections for patients in the intensive care unit (ICU). Comprehensive unit-based programs have proven to be effective in decreasing catheter-related bloodstream infections (CR-BSIs). ICU rates of CR-BSI higher than 2 per 1,000 catheter-days are no longer acceptable. The locally adapted list of preventive measures should include skin antisepsis with an alcoholic preparation, maximal barrier precautions, a strict catheter maintenance policy, and removal of unnecessary catheters. The development of new technologies capable of further decreasing the now low CR-BSI rate is a major challenge. Recently, new materials that decrease the risk of skin-to-vein bacterial migration, such as new antiseptic dressings, were extensively tested. Antimicrobial-coated catheters can prevent CR-BSI but have a theoretical risk of selecting resistant bacteria. An antimicrobial or antiseptic lock may prevent bacterial migration from the hub to the bloodstream. This review discusses the available knowledge about these new technologies. PMID:21906266

  19. Pulsatile flow in ventricular catheters for hydrocephalus

    NASA Astrophysics Data System (ADS)

    Giménez, Á.; Galarza, M.; Thomale, U.; Schuhmann, M. U.; Valero, J.; Amigó, J. M.

    2017-05-01

    The obstruction of ventricular catheters (VCs) is a major problem in the standard treatment of hydrocephalus, the flow pattern of the cerebrospinal fluid (CSF) being one important factor thereof. As a first approach to this problem, some of the authors studied previously the CSF flow through VCs under time-independent boundary conditions by means of computational fluid dynamics in three-dimensional models. This allowed us to derive a few basic principles which led to designs with improved flow patterns regarding the obstruction problem. However, the flow of the CSF has actually a pulsatile nature because of the heart beating and blood flow. To address this fact, here we extend our previous computational study to models with oscillatory boundary conditions. The new results will be compared with the results for constant flows and discussed. It turns out that the corrections due to the pulsatility of the CSF are quantitatively small, which reinforces our previous findings and conclusions. This article is part of the themed issue `Mathematical methods in medicine: neuroscience, cardiology and pathology'.

  20. Catheter guided by optical coherence domain reflectometry

    DOEpatents

    Everett, Matthew; Colston, Billy W.; Da Silva, Luiz B.; Matthews, Dennis

    2002-01-01

    A guidance and viewing system based on multiplexed optical coherence domain reflectometry is incorporated into a catheter, endoscope, or other medical device to measure the location, thickness, and structure of the arterial walls or other intra-cavity regions at discrete points on the medical device during minimally invasive medical procedures. The information will be used both to guide the device through the body and to evaluate the tissue through which the device is being passed. Multiple optical fibers are situated along the circumference of the device. Light from the distal end of each fiber is directed onto the interior cavity walls via small diameter optics (such as gradient index lenses and mirrored corner cubes). Both forward viewing and side viewing fibers can be included. The light reflected or scattered from the cavity walls is then collected by the fibers and multiplexed at the proximal end to the sample arm of an optical low coherence reflectometer. The system may also be implemented in a nonmedical inspection device.

  1. Fast integrated intravascular photoacoustic/ultrasound catheter

    NASA Astrophysics Data System (ADS)

    Choi, Changhoon; Cho, Seunghee; Kim, Taehoon; Park, Sungjo; Park, Hyoeun; Kim, Jinmoo; Lee, Seunghoon; Kang, Yeonsu; Jang, Kiyuk; Kim, Chulhong

    2016-03-01

    In cardiology, a vulnerable plaque is considered to be a key subject because it is strongly related to atherosclerosis and acute myocardial infarction. Because conventional intravascular imaging devices exhibit several limitations with regard to vulnerable plaque detection, the need for an effective lipid imaging modality has been continuously suggested. Photoacoustic (PA) imaging is a medical imaging technique with a high level of ultrasound (US) resolution and strong optical contrast. In this study, we successfully developed an integrated intravascular photoacoustic/ultrasound (IV-PAUS) imaging system with a catheter diameter of 1.2 mm for lipid-rich atherosclerosis imaging. An Nd:YAG pulsed laser with an excitation wavelength of 1064 nm was utilized. IV-PAUS offers 5-mm depth penetration and axial and lateral PA imaging resolutions of 94 μm and 203 μm, respectively, as determined by imaging a 6-μm carbon fiber. We initially obtained 3-dimensional (3D) co-registered PA/US images of metal stents. Subsequently, we successfully obtained 3D coregistered PA/US ex vivo images using an iliac artery from a rabbit atherosclerosis model. Accordingly, lipid-rich plaques were sufficiently differentiated from normal tissue in the ex vivo experiment. We validated these findings histologically to confirm the lipid content.

  2. [Combination of the ureteral dilation catheter and balloon catheter under the ureteroscope in the treatment of male urethral stricture].

    PubMed

    Zhou, Yi; Li, Gong-hui; Yan, Jia-jun; Shen, Cong; Tang, Gui-hang; Xu, Gang

    2016-01-01

    To investigate the clinical application of the ureteral dilation catheter combined with the balloon catheter under the ureteroscope in the treatment of urethral stricture in men. Under the ureteroscope, 45 male patients with urethral stricture received placement of a zebra guide wire through the strictured urethra into the bladder and then a ureteral dilation catheter along the guide wire, followed by dilation of the urethra from F8 initially to F14 and F16. Again, the ureteroscope was used to determine the length of the strictured urethra, its distance to the external urethral orifice, and whether it was normally located. An F24 balloon catheter and then a metal urethral calibrator was used for the dilation of the strictured urethra. After removal of the F18-F22 urethral catheter at 8 weeks, the urinary flow rate was measured immediately and again at 3 months. All the operations were successfully performed without serious complications. The maximum urinary flow rate was (13.3-29.9) ml/s (mean [17.7 ± 3.2] ml/s) at the removal of the catheter and (15.2-30.8) ml/s (mean [19.8 ± 3.9] ml/s) at 3 months after it. Smooth urination was found in all the patients during the 6-24 months follow-up. The application of the ureteral dilation catheter combined with, the balloon catheter under the ureteroscope is a good option for the treatment of male urethral stricture for its advantages of uncomplicatedness, safety, effectiveness, few complications, less pain, high success rate, and repeatable operation.

  3. Point-to-plane and plane-to-plane electrostatic charge injection atomization for insulating liquids

    NASA Astrophysics Data System (ADS)

    Malkawi, Ghazi

    An electrostatic charge injection atomizer was fabricated and used to introduce and study the electrostatic charge injection atomization methods for highly viscous vegetable oils and high conductivity low viscosity aviation fuel, JP8. The total, spray and leakage currents and spray breakup characteristics for these liquids were investigated and compared with Diesel fuel data. Jet breakup and spray atomization mechanism showed differences for vegetable oils and lower viscosity hydrocarbon fuels. For vegetable oils, a bending/spinning instability phenomenon was observed similar to the phenomenon found in liquid jets of high viscosity polymer solutions. The spray tip lengths and cone angles were presented qualitatively and quantitatively and correlated with the appropriate empirical formulas. The different stages of the breakup mechanisms for such oils, as a function of specific charges and flow rates, were discussed. In order to make this method of atomization more suitable for practical use in high flow rate applications, a blunt face electrode (plane-to-plane) was used as the charge emitter in place of a single pointed electrode (point-to-plane). This allowed the use of a multi-orifice emitter that maintained a specific charge with the flow rate increase which could not be achieved with the needle electrode. The effect of the nozzle geometry, liquid physical properties and applied bulk flow on the spray charge, total charge, maximum critical spray specific charge and electrical efficiency compared with the needle point-to-plane atomizer results was presented. Our investigation revealed that the electrical efficiency of the atomizer is dominated by the charge forced convection rate rather than charge transport by ion motilities and liquid motion by the electric field. As a result of the electric coulomb forces between the electrified jets, the multi-orifice atomizer provided a unique means of dispersing the fuel in a hollow cone with wide angles making the new

  4. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    SciTech Connect

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-15

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new cathetersmore » following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance

  5. Utility and safety of Hickman catheters for venous access after bone marrow transplantation.

    PubMed

    Kumagai, T; Sakamaki, H; Tanikawa, S; Akiyama, H; Maeda, Y; Sasaki, T; Tsuzuki, S; Takamoto, S; Takahashi, K; Onozawa, Y

    1998-03-01

    Hickman catheters are useful for vascular access after bone marrow transportation because they can handle large volume and allow for easy transfusions and blood drawing through wide double lumens making it easier to case for patients under sterile conditions in a clean room. However, the safety of Hickman catheters as compared to Silastic catheters in marrow transplants has never been discussed. We therefore retrospectively reviewed the complications of two catheters in 71 allogeneic bone marrow transplant recipients between September 1986 and August 1994. The complication and infection rates of Hickman catheters were 0.21 and 0.09 per 100 device-life days, and rate of temperature >38 degrees C during leukocytopenia (<1,000 white blood cells) was 0.18. These rates were not different from those of Silastic catheters suggesting that Hickman catheters are safe and acceptable in marrow transplantation. The benefits and drawbacks of Hickman catheters relevant to catheter choice were also discussed.

  6. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    PubMed

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  7. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    PubMed

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  8. [Central venous catheter-related infections in critically ill patients].

    PubMed

    Diener, J R; Coutinho, M S; Zoccoli, C M

    1996-01-01

    To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.

  9. Knowledge of nursing students about central venous catheters.

    PubMed

    Mlinar, Suzana; Malnarsić, Rosanda Rasković

    2012-04-01

    Central venous catheters (CVC) are at the crucial importance, particulary in the intensive therapy units. In order to handle a CVC safely, nursing students need to acquire theoretical and practical knowledge during the course of their studies. The aim of the study was to establish theoretical knowledge of nursing students about the procedures of nurses in placing and removing a central venous catheter (CVC), dressing the catheter entry point, the reasons for measuring central venous pressure (CVP), possible complications and risk factors for developing infections related to CVC. The questionnaire developed specifically for this cross-sectionl study was handed out to 87 full-time students and 57 part-time students. The results show that all the surveyed nursing students know why chest radiography is carried out when inserting a catheter, have relatively good knowledge of CVC insertion points, procedures carried out in case of a suspected catheter sepsis and complications and risk factors for the development of infections related to CVC. However, the study show that the majority of students have insufficient knowledge of the procedures accompanying insertion of a catheter, signs that indicate correct functioning of CVC, frequency of flushing a catheter when it is not in use and the reasons for introducing an implanted CVC. Based on the results of the study it can be concluded that the second-year nursing students have insufficient knowledge of CVC. In order to correctly and safely handle a CVC, good theoretical knowledge and relevant practical experience are needed. The authors therefore believe that, in future, the classes should be organized in smaller groups with step-by-step demonstrations of individual procedures in handling a CVC, and the students encouraged to learn as actively as possible.

  10. Catheter fracture of intravenous ports and its management.

    PubMed

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P < 0.05 was considered statistically significant. There were 59 and 1,448 procedures in the fracture and non-fracture groups, respectively. Monovariate analysis revealed that the risk factors for catheter fracture were as follows: large angle (P < 0.0001), female gender (P < 0.0008), subclavian route (P < 0.0001), and port type Arrow French (Fr.) 8.1 (P < 0.0001). Because these risk factors showed no interaction effects, they were all considered independent risk factors. When all factors were considered together, all risk factors, except angle and age, retained their statistical significance. Most catheter fractures were caused by material weakness. If catheter fracture is confirmed, further intervention for port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  11. Turkish nurses' level of knowledge regarding implantable port catheter care.

    PubMed

    Özden, Dilek; Çalişkan, Nurcan

    2012-06-01

    The aim of this study was to determine the knowledge levels of Turkish nurses regarding implantable port catheter care. A descriptive method was used inside a university hospital that was located in a Turkish metropolis. The data were collected via a questionnaire that was given to a total of 45 nurses who were employed in the internal medicine clinics where the oncology patients were treated. In this study, 42.2% of the nurses received in-service training about the implantable port catheter. It was determined that the mean knowledge point was 15.13 ± 4.78. The difference between the knowledge points of the nurses regarding implantable port catheter care, based on whether or not the nurses had received in-service training, was statistically significant. Moreover, it was determined that the majority of the nurses did not know where the implantable port catheter is placed, its period of use following implantation, the amount of normal saline to be used for washing the catheter, the special port (Huber) needle, the number of the needle, and the exchange time of these needles. In this study, there existed significant differences between the scores of the nurses who received in-service training about the implantable port catheter and the scores of those who did not receive in-service training. The majority of the nurses who participated in the study were willing to receive in-service training regarding this subject. Thus, the organization of in-service training programs and the implementation of care, according to the developed standards and guidelines, are considered as significant for reducing the occurrence of the complications that are related to the use of the implantable port catheter. © 2011 The Authors. Japan Journal of Nursing Science © 2011 Japan Academy of Nursing Science.

  12. Cryo-balloon catheter position planning using AFiT

    NASA Astrophysics Data System (ADS)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  13. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    PubMed

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  14. The Bolocam Galactic Plane Survey

    NASA Technical Reports Server (NTRS)

    Glenn, Jason; Aguirre, James; Bally, John; Battersby, Cara; Bradley, Eric Todd; Cyganowski, Claudia; Dowell, Darren; Drosback, Meredith; Dunham, Miranda K.; Evans, Neal J., II; hide

    2009-01-01

    The Bolocam Galactic Plane Survey (BGPS) is a 1.1 millimeter continuum survey of the northern Galactic Plane made with Bolocam and the Caltech Submillimeter Observatory. The coverage totals 170 square degrees, comprised of a contiguous range from -10.5 deg is less than or equal to 90.5 deg, 0.5 deg is less than or equal to b is less than or equal to 0.5 deg, with extended coverage in b in selected regions, and four targeted regions in the outer Galaxy, including: IC1396, toward the Perseus arm at l is approximately 111 deg, W3/4/5, and Gem OB1. Depths of the maps range from 30 to 60 mJy beam (sup 1). Approximately 8,400 sources were detected and the maps and source catalog have been made publicly available. Millimeter-wave thermal dust emission reveals dense regions within molecular clouds, thus the BGPS serves as a database for studies of the dense interstellar medium and star formation within the Milky Way.

  15. Attitudes and knowledge of urethral catheters: a targeted educational intervention.

    PubMed

    Cohen, Andrew; Nottingham, Charles; Packiam, Vignesh; Jaskowiak, Nora; Gundeti, Mohan

    2016-10-01

    To assess the training of medical students and their confidence in urethral catheter placement, given growing evidence of unnecessary urology consults and iatrogenic injury. A third-year medical school class was queried about their attitudes and knowledge of catheter placement before and after the Clinical Biennium. The Clinical Biennium introduces hands-on skills prior to clinical clerkships. Urethral catheterisation is one of the skill stations that students rotate through, and urology residents provide a didactic session and supervised simulation. Confidence was self-rated regarding catheter technique, knowledge, troubleshooting, and comfort with placement in the same and opposite gender. Factual questions were posed about proper insertion and malfunctioning catheters. In all, 92 students participated in the initial survey, 41% female and 59% male, and 87% of the students had never placed a catheter. Students desired high confidence in catheter skills (4.4/5). There were no significant differences in responses for those with a desire to pursue urology vs other specialties, or procedural fields compared with non-procedural fields. Prior independent learning was reported by 38% of students and was a predictor for increased confidence across all domains (P < 0.05). In all, 16.7% of students initially identified proper male urethral insertion distance, which improved to 95.6% after the session. Student interest in urology modestly increased after the educational session (P = 0.028). At 3-6 months follow-up, students had performed a median (interquartile range) of 4 (2-7) urethral catheter placements, and 74.2% of students rated training useful or extremely useful. Indeed, 54.8% desired more instruction. Knowledge assessment indicated that 93% of students retained comprehension of proper male urethral insertion distance. Clinical Foley training rarely contradicted instruction from the Clinical Biennium (6.5%). At all time-points, medical student knowledge for

  16. Remote magnetic navigation for circumferential pulmonary vein ablation: single-catheter technique or additional use of a circular mapping catheter?

    PubMed

    Vollmann, Dirk; Lüthje, Lars; Seegers, Joachim; Sohns, Christian; Sossalla, Samuel; Sohns, Jan; Röver, Christian; Hasenfuß, Gerd; Zabel, Markus

    2014-10-01

    Remote magnetic navigation (RMN) is utilized for catheter guidance during pulmonary vein ablation (PVA). We aimed to determine whether the additional use of a circular mapping catheter (CMC) influences efficacy and outcome of RMN-guided PVA. A total of 80 consecutive subjects (65 % male, age 62 ± 9 years) underwent circumferential PVA with a 3D mapping system and an RMN-guided irrigated catheter. Procedural endpoint was complete PV isolation (PVI), total radiofrequency (RF) time >60 min, or procedure duration >5 h. PVI was defined as an entrance and/or exit block, diagnosed with a CMC within the PV ostium or by pacing via the roving RMN-guided catheter (single-catheter technique). Prolonged Holter monitoring after 3 and 6 months was used to detect atrial tachyarrhythmia (AT/AF) recurrences. Complete PVI was achieved in 56 % (45/80) of all subjects (isolated PVs per patient, 3.1 ± 1.2; RF time, 56.3 ± 17.2 min; procedure duration, 3.8 ± 0.8 h). Prospective validation of the single-catheter technique for diagnosing PVI demonstrated high concordance (94 %) with blinded CMC results. CMC use in first-time PVA was associated with similar total RF and procedure times but higher PV isolation rate. Upon multivariate analysis, CMC use, female gender, left PV, smaller PV ostium and repeat PVA predicted PVI during RMN-guided ablation. Persistent AF and mitral regurgitation at baseline and the number of non-isolated PVs predicted AT/AF recurrence during follow-up. Concomitant CMC use for first-time, RMN-guided PVA is associated with similar procedure duration but higher PV isolation rates as compared to a single-catheter approach. Since the number of isolated PVs predicts freedom from AT/AF, CMC utilization appears advisable for first-time, RMN-guided PVA.

  17. Effectiveness of dry needling of rectus abdominis trigger points for the treatment of primary dysmenorrhoea: a randomised parallel-group trial.

    PubMed

    Gaubeca-Gilarranz, Alberto; Fernández-de-Las-Peñas, César; Medina-Torres, José Raúl; Seoane-Ruiz, José M; Company-Palonés, Aurelio; Cleland, Joshua A; Arias-Buría, Jose L

    2018-05-02

    To compare the effectiveness of trigger point dry needling (TrP-DN) versus placebo needling, relative to an untreated control group, on pain and quality of life in primary dysmenorrhoea. In this randomised, single blind, parallel-group trial, 56 females with primary dysmenorrhoea were randomly allocated to TrP-DN (n=19), placebo needling (n=18) or no treatment (n=19). Patients in both groups were asked to undertake a stretching exercise of the rectus abdominis daily. The needling group received a single session of TrP-DN to trigger points (TrPs) in the rectus abdominis, and the placebo group received placebo needling. The primary outcome was pain intensity (visual analogue scale). Secondary outcomes were quality of life, use of non-steroidal anti-inflammatory drugs, the number of days with pain, and self-perceived improvement, measured using a Global Rate of Change. Outcomes were assessed at baseline, and 1 and 2 months after the treatment. Females receiving TrP-DN exhibited greater decreases (P<0.001) in pain than those receiving placebo (1 month: Δ-19.8 mm, 25.9 to -13.7; 2 months: Δ-26.0 mm, -33.1 to -18.9) or assigned to the untreated control group (1 month: Δ-26.0mm, -32.5 to -19.5; 2 months: Δ-20.1 mm, -26.4 to -13.8). Females in the TrP-DN group also exhibited a greater decrease in the amount of medications (P<0.001). No differences in the number of days with pain or quality of life were found (all P>0.1). This trial suggests that a single session of TrP-DN of the rectus abdominis combined with stretching was more effective than placebo needling and stretching alone at reducing pain and the amount of medication used in primary dysmenorrhoea. ACTRN12616000170426. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Catheter tracking in an interventional photoacoustic surgical system

    NASA Astrophysics Data System (ADS)

    Cheng, Alexis; Itsarachaiyot, Yuttana; Kim, Younsu; Zhang, Haichong K.; Taylor, Russell H.; Boctor, Emad M.

    2017-03-01

    In laparoscopic medical procedures, accurate tracking of interventional tools such as catheters are necessary. Current practice for tracking catheters often involve using fluoroscopy, which is best avoided to minimize radiation dose to the patient and the surgical team. Photoacoustic imaging is an emerging imaging modality that can be used for this purpose and does not currently have a general tool tracking solution. Photoacoustic-based catheter tracking would increase its attractiveness, by providing both an imaging and tracking solution. We present a catheter tracking method based on the photoacoustic effect. Photoacoustic markers are simultaneously observed by a stereo camera as well as a piezoelectric element attached to the tip of a catheter. The signals received by the piezoelectric element can be used to compute its position relative to the photoacoustic markers using multilateration. This combined information can be processed to localize the position of the piezoelectric element with respect to the stereo camera system. We presented the methods to enable this work and demonstrated precisions of 1-3mm and a relative accuracy of less than 4% in four independent locations, which are comparable to conventional systems. In addition, we also showed in another experiment a reconstruction precision up to 0.4mm and an estimated accuracy up to 0.5mm. Future work will include simulations to better evaluate this method and its challenges and the development of concurrent photoacoustic marker projection and its associated methods.

  19. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    PubMed

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  20. Rat Indwelling Urinary Catheter Model of Candida albicans Biofilm Infection

    PubMed Central

    Nett, Jeniel E.; Brooks, Erin G.; Cabezas-Olcoz, Jonathan; Sanchez, Hiram; Zarnowski, Robert; Marchillo, Karen

    2014-01-01

    Indwelling urinary catheters are commonly used in the management of hospitalized patients. Candida can adhere to the device surface and propagate as a biofilm. These Candida biofilm communities differ from free-floating Candida, exhibiting high tolerance to antifungal therapy. The significance of catheter-associated candiduria is often unclear, and treatment may be problematic considering the biofilm drug-resistant phenotype. Here we describe a rodent model for the study of urinary catheter-associated Candida albicans biofilm infection that mimics this common process in patients. In the setting of a functioning, indwelling urinary catheter in a rat, Candida proliferated as a biofilm on the device surface. Characteristic biofilm architecture was observed, including adherent, filamentous cells embedded in an extracellular matrix. Similar to what occurs in human patients, animals with this infection developed candiduria and pyuria. Infection progressed to cystitis, and a biofilmlike covering was observed over the bladder surface. Furthermore, large numbers of C. albicans cells were dispersed into the urine from either the catheter or bladder wall biofilm over the infection period. We successfully utilized the model to test the efficacy of antifungals, analyze transcriptional patterns, and examine the phenotype of a genetic mutant. The model should be useful for future investigations involving the pathogenesis, diagnosis, therapy, prevention, and drug resistance of Candida biofilms in the urinary tract. PMID:25183731

  1. [Epidemiology of catheter-related infections in intensive care unit].

    PubMed

    Merrer, J

    2005-03-01

    Catheter-related infections remain an important cause of nosocomial infection in the ICU. They include colonization of the device, exit-site infection and catheter-related bloodstream infection with or without bacteraemia. Data from clinical studies and surveillance networks should be compared cautiously due to important methodological differences and wide variations of device-utilization ratio between units or countries. In France, two regional networks (C-CLIN Paris-Nord and C-CLIN Sud-Est) produced comparable and reproducible results. Colonization represents five-six cases per 1000 catheter-days and bacteraemia represents one case per 1000 catheter-days. Incidence rates from North American studies are usually four to five times higher. Numerous risk factors have been identified. Some of them could be used to stratify patients according to risk of catheter-related infection and to allow more valid comparison between ICU's performances. Participation of French ICUs to the recent national surveillance networks (REA RAISIN and REACAT RAISIN) should be encouraged.

  2. Peripheral intravenous catheter-related phlebitis and related risk factors.

    PubMed

    Nassaji-Zavareh, M; Ghorbani, R

    2007-08-01

    Peripheral intravenous catheter-related phlebitis is a common and significant problem in clinical practice. This study aims to investigate the incidence of phlebitis and to evaluate some important related factors. 300 patients admitted to medical and surgical wards of hospitals in Semnan, Iran from April 2003 to February 2004 were prospectively studied. Variables evaluated were age, gender, site and size of catheter, type of insertion and underlying conditions (diabetes mellitus, trauma, infectious disease and burns). Phlebitis was defined when at least four criteria were fulfilled (erythema, pain, tenderness, warmth, induration, palpable cord and swelling). Any patient who was discharged or their catheter removed before three days were excluded. Phlebitis occurred in 26 percent (95 percent confidence interval [CI] 21- 31 percent) of patients. There was no significant relationship between age, catheter bore size, trauma and phlebitis. Related risk factors were gender (odds-ratio [OR] 1.50, 95 percent CI 1.01-2.22), site (OR 3.25, 95 percent CI 2.26-4.67) and type of insertion (OR 2.04, 95 percent CI 1.36-3.05) of catheter, diabetes mellitus (OR 7.78, 95 percent CI 4.59-13.21), infectious disease (OR 6.21, 95 percent CI 4.27-9.03) and burns (OR 3.96, 95 percent CI 3.26-4.82). Phlebitis is still an important and ongoing problem in medical practice. In patients with diabetes mellitus and infectious diseases, more attention is needed.

  3. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    PubMed

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  4. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    PubMed

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  5. Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.

    PubMed

    Macha, Douglas B; Thomas, John; Nelson, Rendon C

    2006-03-01

    To compare the performance characteristics of various single-lumen all-purpose pigtail drainage catheters. The following parameters were compared: flow rates between catheters of the same size, whether changing the fluid viscosity has any effect on catheter comparisons, the effect on flow of leaving an open three-way stopcock in the drainage pathway, the tendency of the catheters to kink, and catheter patency after kinking, as measured according to flow. All-purpose 8.0-, 8.3-, and 8.5-F (collectively referred to as 8-F); 10.0-, 10.2-, and 10.3-F (collectively referred to as 10-F); and 12.0-F pigtail drainage catheters from three manufacturers were evaluated. Data were compared by using two-tailed t tests after normal distributions were confirmed. P < .05 was considered to represent a significant difference. At comparison of the 8-F catheters, the C.R. Bard catheters demonstrated better flow rates than the Cook and Boston Scientific devices. Among the 10-F catheters, there were no significant differences in the flow rates of fluid with viscosity equivalent to that of water between the C.R. Bard and Boston Scientific catheters; however, both these catheter types demonstrated significantly (P < .05) better flow rates than the Cook devices. Among the 12-F catheters, the C.R. Bard catheters demonstrated significantly (P < .05) better flow rates than the other two catheter types. Changing the fluid viscosity caused no changes in comparison results. In all catheter groups, the presence of a stopcock significantly (P < .05) impaired flow. None of the evaluated catheters demonstrated a clear advantage in terms of patency or susceptibility to kinking. At comparison of the in vitro performances of catheters from different manufacturers, the C.R. Bard 8.0-F and Cook 10.2-F catheters had comparable flow rates, and flow rates through the C.R. Bard and Boston Scientific 10.0-F catheters were comparable to flow rates through the Cook and Boston Scientific 12.0-F catheters

  6. Postcard from the Ring Plane

    NASA Image and Video Library

    2018-05-07

    On March 13, 2006 Cassini's narrow-angle camera captured this look at Saturn and its rings, seen here nearly edge on. The frame also features Mimas and tiny Janus (above the rings), and Tethys (below the rings). "Above" and "below" the rings is mostly a matter of perspective here. All three moons and the rings orbit Saturn in roughly the same plane. The night side of Mimas is gently illuminated by "Saturnshine," sunlight reflected from the planet's cloud tops. Images taken using red, green and blue spectral filters were combined to create this natural color view, taken at a distance of approximately 1.7 million miles (2.7 million kilometers) from Saturn. The Cassini spacecraft ended its mission on Sept. 15, 2017. https://photojournal.jpl.nasa.gov/catalog/PIA18323

  7. Optimal focal-plane restoration

    NASA Technical Reports Server (NTRS)

    Reichenbach, Stephen E.; Park, Stephen K.

    1989-01-01

    Image restoration can be implemented efficiently by calculating the convolution of the digital image and a small kernel during image acquisition. Processing the image in the focal-plane in this way requires less computation than traditional Fourier-transform-based techniques such as the Wiener filter and constrained least-squares filter. Here, the values of the convolution kernel that yield the restoration with minimum expected mean-square error are determined using a frequency analysis of the end-to-end imaging system. This development accounts for constraints on the size and shape of the spatial kernel and all the components of the imaging system. Simulation results indicate the technique is effective and efficient.

  8. Suicide by severing the arterio-venous subclavian dialysis catheter.

    PubMed

    Edirisinghe, P A S; Busuttil, A

    2006-02-01

    Haemodialysis access is an essential requirement for haemodialysis treatment in end-stage renal disease. The common forms are arteriovenous fistula (AVF) and arteriovenous grafts in ante-cubital fossa, forearm and upper thigh. Sometimes temporary or immediate access is created via a subclavian catheter or internal jugular catheter. This report is on a 79-year-old man who was suffering from chronic renal failure with a non-functional peripheral AVF; he was being dialysed through a permanent subclavian catheter and he became depressed due to continuing deterioration of his health. He used the easily accessible haemodialysis site as the method of suicide by cutting the tube that connected with the main vessel in his chest and bled to death. This highlights the requirement to assess carefully the patient's mental state in those on chronic haemodialysis, even though very few similar fatal cases have been previously reported.

  9. [Intrathoracic migration of a ventriculoperitoneal shunt catheter: a case report].

    PubMed

    Sánchez-Medina, Yanire; Domínguez-Báez, Jaime; Lazo-Fernández, Eglis; Pérez Del Rosario, Pedro Antonio; Zanabria-Ortiz, Robert

    2015-01-01

    The intrathoracic complications from ventriculoperitoneal shunt placement are very rare. However, they are potentially serious if not treated. We report the case of thoracic migration of a peritoneal catheter after ventriculoperitoneal shunt and we also review the literature references with discussion of the different mechanisms of shunt-tip migration described. No case of previous sternotomy as in our patient has been found published. All reports recommend early catheter repositioning into the peritoneal cavity after diagnosing the migration described, to prevent worse complications. Moreover, it is important to keep in mind that intrathoracic migration can happen and it is necessary to palpate the catheter continuously during passage through subcutaneous tunnelling to prevent it. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  10. Catheter-associated bacteremia by Mycobacterium senegalense in Korea

    PubMed Central

    Oh, Won Sup; Ko, Kwan Soo; Song, Jae-Hoon; Lee, Mi Young; Ryu, Seong Yeol; Heo, Sangtaek; Kwon, Ki Tae; Lee, Jang-Ho; Peck, Kyong Ran; Lee, Nam Yong

    2005-01-01

    Background Rapidly growing mycobacteria is recognized as one of the causative agents of catheter-related infections, especially in immunocompromised hosts. To date, however, Mycobacterium senegalense, which was known as the principal pathogen of bovine farcy, has not been reported in human infection. Case presentation We describe the first case of human infection by M. senegalense, which has caused catheter-related bloodstream infection in a cancer patient in Korea. The microorganism was identified by the 16S rRNA gene, rpoB, and 16S-23S rRNA gene internal transcribed spacer (ITS) sequence analyses. Conclusion Our first report of catheter-associated bacteremia caused by M. senegalense suggests the zoonotic nature of this species and indicates the expansion of mycobacterial species relating to human infection. M. senegalense should be considered as one of the causes of human infections in the clinical practice. PMID:16307688

  11. Catheter use and infection reduction in plastic surgery

    PubMed Central

    Barnes, Zach J; Mahabir, Raman C

    2013-01-01

    BACKGROUND: Catheter-associated urinary tract infections (CAUTI) are the most common hospital-associated infection and can result in increased health care costs, morbidity and even mortality. In 2009, The Scott & White Memorial Hospital/Texas A&M Health Science Center (Texas, USA) system’s CAUTI rate placed it in the upper quartile (ie, highest rate) for the country, necessitating a system-wide change. OBJECTIVE: To design and implement a guideline to reduce the incidence of CAUTI. METHODS: A multidisciplinary team was formed and completed both a root cause analysis and a review of the available literature. Consolidating the best evidence, the team formulated a best practice guideline detailing the proper indications for insertion of, improper use of and techniques to minimize infection with catheters. Included as part of this protocol was nursing and patient education, changes in identifying patients with a catheter and automatic termination orders. Three-, six- and 12-month reviews identifying additional opportunities for improvement at the end of 2010 were completed. RESULTS: In 2009, the hospital’s CAUTI rate was 1.46 per 1000 catheter days. In 2011 – the first complete year of the finalized guideline – the hospital’s CAUTI rate was 0.52 per 1000 catheter days, ranking the institution in the bottom quartile (ie, lowest rate) for the country. The surgery and plastic surgery subgroup analyses also demonstrated statistically significant reduction in both catheter use and CAUTI. CONCLUSION: The incidence of CAUTI was successfully reduced at The Texas A&M Healthcare Center. The guideline, its development and how it applies to plastic surgery patients are discussed. PMID:24431946

  12. Minimally invasive fluoroscopic percutaneous peritoneal dialysis catheter salvage.

    PubMed

    Narayan, Rajeev; Fried, Terrance; Chica, Gerardo; Schaefer, Mathew; Mullins, Daniel

    2014-06-01

    Peritoneal dialysis catheter (PDC) dysfunction can often be treated fluoroscopically by manipulation with wire, balloon or stiff stylet, saving surgical intervention for refractory cases. We describe an enhanced percutaneous approach to PDC salvage that can lead to a more definitive intervention and salvage for cases refractory to fluoroscopic manipulation. In five cases of PD catheter malfunction, the deep cuff was dissected free after a 0.035 hydrophilic wire was passed into the peritoneum through the PDC. Only the intraperitoneal portion of the PDC was explanted. The PDC was cleared of obstruction and omentum. The intraperitoneal portion of the PDC was reimplanted over wire via a peel-away sheath and the deep cuff sutured. Omental entrapment was present in three of five patients and fibrin occlusion in four of the five cases. All catheters were repaired successfully by the described technique. Post procedure, 3-5 days of lower volume, recumbent PD exchanges were performed prior to full-dose PD. No perioperative complications or leaks were noted. All PDCs were patent at 6 months. One patient required laparoscopy for recurrent omental wrapping 3 months post intervention. PDC salvage in this manner is a cost-effective alternative to laparoscopic repair of PDCs failing catheter manipulation. The infection barrier afforded by the original superficial cuff and subcutaneous tunnel is maintained. PD can be resumed immediately. Only refractory cases need laparoscopy. This procedure allows for a more definitive correction of catheter migration and obstruction, avoids placement of a new PDC or temporary hemodialysis, is cost-effective and expands percutaneous options for dysfunctional PD catheters.

  13. Catheter-Related Bloodstream Infections in Patients on Emergent Hemodialysis.

    PubMed

    Rojas-Moreno, Christian A; Spiegel, Daniel; Yalamanchili, Venkata; Kuo, Elizabeth; Quinones, Henry; Sreeramoju, Pranavi V; Luby, James P

    2016-03-01

    This study had 2 objectives: (1) to describe the epidemiology of catheter-related bloodstream infections (CRBSI) in patients with end-stage renal disease (ESRD) who have no access to scheduled dialysis and (2) to evaluate whether a positive culture of the heparin-lock solution is associated with subsequent development of bacteremia. Retrospective observational cohort design for objective 1; and prospective cohort design for objective 2. The study was conducted in a 770-bed public academic tertiary hospital in Dallas, Texas. The participants were patients with ESRD undergoing scheduled or emergent hemodialysis. We reviewed the records of 147 patients who received hemodialysis between January 2011 and May 2011 and evaluated the rate of CRBSI in the previous 5 years. For the prospective study, we cultured the catheter heparin-lock solution in 62 consecutive patients between June 2012 and August 2012 and evaluated the incidence of CRBSI at 6 months. Of the 147 patients on emergent hemodialysis, 125 had a tunneled catheter, with a CRBSI rate of 2.61 per 1,000 catheter days. The predominant organisms were Gram-negative rods (GNR). In the prospective study, we found that the dialysis catheter was colonized more frequently in patients on emergent hemodialysis than in those on scheduled hemodialysis. Colonization with GNR or Staphylococcus aureus was associated with subsequent CRBSI at 6 months follow-up. Patients undergoing emergent hemodialysis via tunneled catheter are predisposed to Gram-negative CRBSI. Culturing the heparin-lock solution may predict subsequent episodes of CRBSI if it shows colonization with GNR or Staphylococcus aureus. Prevention approaches in this population need to be studied further.

  14. A Spine Loading Model of Women in the Military

    DTIC Science & Technology

    1999-10-01

    Table 1.8. Left erector spinae anatomical cross-sectional areas ..................................... 42 Table 1.9. Right rectus abdominis anatomical...cross-sectional areas ................................ 43 Table 1.10. Left rectus abdominis anatomical cross-sectional areas...Right rectus abdominis coronal plane moment-arms ....................................... 59 Table 1.26. Left rectus abdominis coronal plane moment-arms

  15. Ultrasound-guided transversus abdominal plane block with multimodal analgesia for pain management after total abdominal hysterectomy.

    PubMed

    Gasanova, Irina; Grant, Erica; Way, Megan; Rosero, Eric B; Joshi, Girish P

    2013-07-01

    Transversus abdominis plane (TAP) block has been shown to provide pain relief after abdominal procedures. However, TAP block combined with multimodal analgesia technique have not been assessed in a randomized controlled trial. This randomized, controlled, observer-blinded study was designed to evaluate the analgesic efficacy of bilateral ultrasound-guided TAP blocks with or without acetaminophen and non-steroidal anti-inflammatory drug (NSAID) combination. Patients undergoing total abdominal hysterectomy were randomized to one of three groups. Group 1 (n = 25) received a TAP block and ketorolac 30 mg, IV at the end of surgery and then ketorolac plus paracetamol 650 mg, orally, every 6 h for 24 h. Group 2 (n = 24) received only TAP block at the end of surgery. Group 3 (n = 25) received ketorolac 30 mg, IV at the end of surgery and then ketorolac plus paracetamol 650 mg, orally, every 6 h for 24 h. All patients received IV-PCA morphine for 24-h, postoperatively. All patients received a standardized general anaesthetic technique and dexamethasone 4 mg and ondansetron 4 mg, IV for antiemetic prophylaxis. There were no statistically significant differences in pain at rest between the groups. However, the pain on coughing (dynamic pain) in Group 1 was significantly less variable, compared with the other two groups (P = 0.012). Opioid consumption and occurrences of nausea, vomiting, and rescue antiemetic were similar in three the groups. The combination of TAP block and acetaminophen and NSAID provided less variability in dynamic pain compared with either treatment alone.

  16. Neurolytic transversus abdominal plane block with alcohol for long-term malignancy related pain control.

    PubMed

    Hung, Joseph C; Azam, Nyla; Puttanniah, Vinay; Malhotra, Vivek; Gulati, Amitabh

    2014-01-01

    There have been several case reports in the literature of neurolytic transversus abdominis plane (TAP) blocks being used for malignant abdominal wall pain. However, most used phenol as a neurolytic agent. We found only a single case report by Sakamoto using alcohol for TAP neurolysis. Unfortunately this patient passed away only 5 days after performance of the block. We attempt to extend upon the existing literature by describing neurolytic TAP blockade outcomes using alcohol on 3 cancer patients with metastatic disease to the abdominal wall. Two of our 3 patients had colorectal cancer invading the abdominal musculature. The third patient had a metastatic neuroendocrine nodule in the left rectus muscle. In our case series, all 3 patients had sustained and significant (greater than 50%) relief of abdominal wall pain after performing TAP neurolysis using alcohol. Ultrasound guidance was used for all blocks. The concentration of alcohol used varied from 33% to 77% between patients. Duration of relief lasted between 17 days and 6 months. Opioid use either decreased or remained relatively stable for prolonged periods of time after neurolysis. Other than one patient with transient post-procedure pain related to alcohol injection, there were no significant complications. Addition of a depo steroid for diagnostic TAP blockade prior to neurolysis did not appear to extend or provide additional analgesia. Based on our observations, TAP neurolysis using alcohol also offers a feasible option for long-term control of malignant abdominal wall pain. Further investigation is needed to determine if alcohol offers any significant advantage compared with phenol.

  17. Cost-Effectiveness of a Central Venous Catheter Care Bundle

    PubMed Central

    Halton, Kate A.; Cook, David; Paterson, David L.; Safdar, Nasia; Graves, Nicholas

    2010-01-01

    Background A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI). Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. Methods and Findings A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters), or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. Conclusions A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision makers must be prepared

  18. The catheter hub disinfection cap as esophageal foreign body.

    PubMed

    Tawfik, Kareem O; Myer, Charles M; Shikary, Tasneem; Goldschneider, Kenneth R

    2015-12-01

    Disinfection caps are increasingly being used to prevent catheter-associated bloodstream infections. These devices, designed for continuous passive disinfection of catheter hubs, are typically small and often brightly colored. As such, they have the potential to become pediatric airway and esophageal foreign bodies. We report two patients who developed esophageal foreign body following ingestion of disinfection caps. Given the increasing use of these devices, it is imperative that health care providers be aware of this potential iatrogenic problem. We propose that the use of disinfection caps may not be appropriate in pediatric patients with risk factors for foreign body ingestion. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Rectus sheath catheter infusions for post-operative pain management.

    PubMed

    Layzell, Mandy

    2014-06-24

    Managing pain following major abdominal surgery remains a challenge. Traditionally, patient-controlled analgesia (PCA) or epidural analgesia have been used, which have improved post-operative pain and the patient experience, but have presented some problems in recovery. PCA can cause adverse effects, including sedation, nausea, vomiting, and prolonged gastric ileus. While epidurals do have some advantages over PCA, there are risks involved related to catheter insertion and adverse effects, such as hypotension and motor blocks which limit mobility. This article examines rectus sheath catheter infusions, a relatively new and alternative technique to epidural analgesia, and presents some early audit data related to pain scores, analgesic use and mobility.

  20. Cost-effectiveness of a central venous catheter care bundle.

    PubMed

    Halton, Kate A; Cook, David; Paterson, David L; Safdar, Nasia; Graves, Nicholas

    2010-09-17

    A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI). Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters), or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision makers must be prepared to invest resources in infection control to

  1. Catheter-based interventions for acute ischaemic stroke.

    PubMed

    Widimsky, Petr; Hopkins, L Nelson

    2016-10-21

    Catheter-based interventions for acute ischaemic stroke currently include clot removal (usually from the medial cerebral artery) with modern stent-retrievers and in one of five patients (who have simultaneous or stand-alone internal carotid occlusion) also extracranial carotid intervention. Several recently published randomized trials clearly demonstrated superiority of catheter-based interventions (with or without bridging thrombolysis) over best medical therapy alone. The healthcare systems should adopt the new strategies for acute stroke treatment (including fast track to interventional lab) to offer the benefits to all suitable acute stroke patients. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  2. Central Venous Catheter-related Fungemia Caused by Rhodotorula glutinis.

    PubMed

    Miglietta, Fabio; Letizia Faneschi, Maria; Braione, Adele; Palumbo, Claudio; Rizzo, Adriana; Lobreglio, Giambattista; Pizzolante, Maria

    2015-01-01

    Bloodstream infection due to Rhodotorula glutinis is extremely rare and mostly associated with underlying immunosuppression or cancer. Vascular access devices provide the necessary surfaces for biofilm formation and are currently responsible for a significant percentage of human infections. In this work, we describe a rare case of central venous catheter-related Rhodotorula glutinis fungemia in a female patient with acute myelogenous leukemia in remission. The timely removal of central venous catheter was an essential element for overcoming this CVC-related Rhodotorula fungemia.

  3. [Delayed (tension) pneumothorax after placement of a central venous catheter].

    PubMed

    Tan, E C; van der Vliet, J A

    1999-09-11

    Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.

  4. The missing foley catheter: an unusual finding in vesicouterine fistula

    PubMed Central

    Shephard, Steven N.; Lengmang, Sunday J.

    2013-01-01

    A 28-year-old G1P1 presented complaining of urine leakage per vaginum following caesarean delivery, accompanied by amenorrhoea, cyclic haematuria and cyclic pelvic pain. Examination findings were suggestive of vesicouterine fistula and the patient was taken for exploratory laparotomy, during which the foley catheter could not be identified within the bladder. During separation of the bladder from the uterus, the catheter was found to be traversing the fistulous tract into the uterine cavity. Vesicouterine fistula is a fairly uncommon type of urogenital fistula that is frequently associated with caesarean section. Surgical treatment remains the mainstay and successfully cured this patient. PMID:24968444

  5. The relationship of transversus abdominis and lumbar multifidus activation and prognostic factors for clinical success with a stabilization exercise program: a cross-sectional study.

    PubMed

    Hebert, Jeffrey J; Koppenhaver, Shane L; Magel, John S; Fritz, Julie M

    2010-01-01

    Hebert JJ, Koppenhaver SL, Magel JS, Fritz JM. The relationship of transversus abdominis and lumbar multifidus activation and prognostic factors for clinical success with a stabilization exercise program: a cross-sectional study. To examine the relationship between prognostic factors for clinical success with a stabilization exercise program and lumbar multifidus (LM) and transversus abdominis (TrA) muscle activation assessed using rehabilitative ultrasound imaging (RUSI). Cross-sectional study. Outpatient physical therapy clinic. Volunteers with current low back pain (N=40). Not applicable. We examined the relationship between prognostic factors associated with clinical success with a stabilization exercise program (positive prone instability test, age <40y, aberrant movements, straight leg raise >91 degrees , presence of lumbar hypermobility) and degree of TrA and LM muscle activation assessed by RUSI. Significant univariate relationships were identified between LM muscle activation and the number of prognostic factors present (Pearson correlation coefficient [r] =-.558, P=.001), as well as the individual factors of a positive prone instability test (point biserial correlation coefficient [r(pbis)]=.376, P=.018) and segmental hypermobility (r(pbis)=.358, P=.025). The multivariate analyses indicated that after controlling for other variables, the addition of the variable "number of prognostic factors present" resulted in a significant increase in R(2) (P=.006). No significant univariate or multivariate relationships were observed between the prognostic factors and TrA muscle activation. Decreased LM muscle activation, but not TrA muscle activation, is associated with the presence of factors predictive of clinical success with a stabilization exercise program. Our findings provide researchers and clinicians with evidence regarding the construct validity of the prognostic factors examined in this study, as well as the potential clinical importance of the LM muscle

  6. Dynamic Article: Tandem Robotic Technique of Extralevator Abdominoperineal Excision and Rectus Abdominis Muscle Harvest for Immediate Closure of the Pelvic Floor Defect.

    PubMed

    Singh, Puneet; Teng, Edward; Cannon, Lisa M; Bello, Brian L; Song, David H; Umanskiy, Konstantin

    2015-09-01

    Extralevator abdominoperineal excision for distal rectal cancers involves cylindrical excision of the mesorectum with wide division of the levator ani muscles. Although this technique has been shown to decrease local cancer recurrence and improve survival, it leaves the patient with a considerable pelvic floor defect that may require reconstruction. We developed an innovative technique of robotic extralevator abdominoperineal excision combined with robotic harvest of the rectus abdominis muscle flap for immediate reconstruction of the pelvic floor defect. This was a retrospective review pilot study. This study was conducted at a tertiary care cancer center. Three patients who underwent robotic extralevator abdominoperineal excision with robotic rectus abdominis flap harvest for distal rectal adenocarcinoma were included. Intraoperative and postoperative outcomes included operative time, intraoperative complications, length of hospital stay, wound complications, incidence of perineal hernia, persistent pain, and functional limitations. Three patients underwent this procedure. The median operative time was 522 minutes with median hospital stay of 6 days. One patient experienced perineal wound complication requiring limited incision and drainage followed by complete healing of the wound by secondary intention. The other 2 patients did not experience any wound complications. Longest follow-up was 16 months. None of the patients developed perineal hernias during this time period. The small sample size and retrospective nature were limitations. This technique confers multiple advantages including improved visualization and dexterity within the pelvis and accurate wide margins at the pelvic floor. An incisionless robotic flap harvest with preservation of the anterior rectus sheath obviates the risk of ventral hernia while providing robust tissue closure of the radiated abdominoperineal excision wound. This technique may result in faster postoperative recovery, decreased

  7. Prevalence and risk factors of diastasis recti abdominis from late pregnancy to 6 months postpartum, and relationship with lumbo-pelvic pain.

    PubMed

    Fernandes da Mota, Patrícia Gonçalves; Pascoal, Augusto Gil Brites Andrade; Carita, Ana Isabel Andrade Dinis; Bø, Kari

    2015-02-01

    Diastasis recti abdominis (DRA) is an impairment characterized by a midline separation of the rectus abdominis muscles along the linea alba. It has its onset during pregnancy and the first weeks following childbirth. There is scant knowledge on both prevalence and risk factors for development of the condition. The aim of this study was to investigate the prevalence of DRA at gestational week 35 and three timepoints postpartum, possible risk factors, and the relationship between DRA and lumbo-pelvic pain. Ultrasound images of inter rectus distance (IRD) were recorded in 84 healthy primiparous women, at three locations on the linea alba. The IRD was measured at: gestational week 35 and 6-8, 12-14, and 24-26 weeks postpartum. Diagnosis of DRA was defined as 16 mm at 2 cm below the umbilicus. Independent sample t-test and binary logistic regression was used to assess differences and risk factors in women with and without DRA and women with and without lumbo-pelvic pain. P < 0.05 was considered statistically significant. The prevalence of DRA decreased from 100% at gestational week 35-39% at 6 months postpartum. No statistically significant differences were found in prepregnancy body mass index (BMI), weight gain, baby's birth weight or abdominal circumference between women with and without DRA at 6 months postpartum. Women with DRA at 6 months postpartum were not more likely to report lumbo-pelvic pain than women without DRA. DRA is prevalent at 6 months postpartum, but is not linked with lumbo-pelvic pain. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    PubMed

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  9. Broken chiral symmetry on a null plane

    SciTech Connect

    Beane, Silas R., E-mail: silas@physics.unh.edu

    2013-10-15

    On a null-plane (light-front), all effects of spontaneous chiral symmetry breaking are contained in the three Hamiltonians (dynamical Poincaré generators), while the vacuum state is a chiral invariant. This property is used to give a general proof of Goldstone’s theorem on a null-plane. Focusing on null-plane QCD with N degenerate flavors of light quarks, the chiral-symmetry breaking Hamiltonians are obtained, and the role of vacuum condensates is clarified. In particular, the null-plane Gell-Mann–Oakes–Renner formula is derived, and a general prescription is given for mapping all chiral-symmetry breaking QCD condensates to chiral-symmetry conserving null-plane QCD condensates. The utility of the null-planemore » description lies in the operator algebra that mixes the null-plane Hamiltonians and the chiral symmetry charges. It is demonstrated that in a certain non-trivial limit, the null-plane operator algebra reduces to the symmetry group SU(2N) of the constituent quark model. -- Highlights: •A proof (the first) of Goldstone’s theorem on a null-plane is given. •The puzzle of chiral-symmetry breaking condensates on a null-plane is solved. •The emergence of spin-flavor symmetries in null-plane QCD is demonstrated.« less

  10. Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: a prospective, randomised, participant-blinded, crossover study of three different types of catheters.

    PubMed

    Stensballe, J; Looms, D; Nielsen, P N; Tvede, M

    2005-12-01

    To compare two hydrophilic-coated (SpeediCath and LoFric and one uncoated gel-lubricated catheter (InCare Advance Plus) concerning withdrawal friction force and urethral micro trauma. 49 healthy male volunteers participated in this prospective, randomised, blinded, crossover study of three different bladder catheters. The withdrawal friction force was measured, and urine analysis of blood, nitrite and leucocytes, microbiological analysis of urine cultures and subjective evaluation of the catheters were performed. 40 participants completed the study and were included in the analysis. SpeediCath exerted a significantly lower mean withdrawal friction force and work than the gel-lubricated uncoated catheter, whereas LoFric exerted a significantly higher mean friction force than both of the other catheters. The hydrophilic catheters caused less microscopic haematuria and less pain than the gel-lubricated uncoated catheter. Furthermore, 93% of the participants preferred the hydrophilic catheters. Hydrophilic-coated catheters perform better than uncoated catheters with regard to haematuria and preference. SpeediCath, but not LoFric, exerts less withdrawal friction force than InCare Advance Plus.

  11. Effect of heparin bonding on catheter-induced fibrin formation and platelet activation.

    PubMed

    Nichols, A B; Owen, J; Grossman, B A; Marcella, J J; Fleisher, L N; Lee, M M

    1984-11-01

    Pathologic and experimental evidence indicates that platelet activation and fibrin formation contribute to the pathogenesis of angina pectoris, coronary vasospasm and myocardial infarction. Detection of localized intravascular platelet activation and fibrin formation in vivo by selective blood sampling requires catheters that do not induce coagulation ex vivo. We studied the effect of heparin bonding of catheter surfaces on activation of the coagulation system by cardiovascular catheters. Woven Dacron, polyvinylchloride, and polyurethane catheters were tested and compared with identical catheters with heparin-bonded surfaces in 47 patients undergoing percutaneous cardiac catheterization. Platelet activation was measured by radioimmunoassay of plasma platelet factor 4 (PF4), beta-thromboglobulin (BTG), and thromboxane B2 (TXB2) in blood samples withdrawn through catheters, and fibrin formation was assessed by determination of fibrinopeptide A (FPA) levels. In blood samples collected through conventional catheters, FPA, PF4, BTG, and TXB2 levels were markedly elevated; blood sampling through heparin-bonded catheters had no significant effect on FPA, PF4, BTG, or TXB2 levels. Scanning electron microscopy disclosed extensive platelet aggregates and fibrin strands adherent to the surface of conventional catheters but not to heparin-bonded catheter surfaces. This study demonstrates that (1) collection of blood samples through cardiovascular catheters causes artifactual elevation of FPA, PF4, BTG, and TXB2 levels, and (2) heparin-bonded catheter surfaces effectively prevent catheter-induced platelet alpha-granule release and fibrin formation on catheter surfaces. Heparin-bonded catheters will facilitate investigation of the role of intravascular coagulation in coronary artery disease by eliminating catheter-induced fibrin formation and platelet activation.

  12. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    PubMed

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  13. Rectus abdominis diastasis.

    PubMed

    Akram, Javed; Matzen, Steen Henrik

    2014-06-01

    Because of the lack of agreement on when rectus diastasis (RD) is pathologic, the aim was to investigate indications for surgical repair. This study presents classifications of RD, current knowledge on the relation to pregnancy, and conservative and surgical management. A systematic search in Pubmed, Embase, Cochrane, and Cinahl revealed 437 studies. Inclusion criteria were applied according to the above mentioned subjects of interest. In total 28 studies were included, representing 3725 patients, 11 of these by assessing reference lists of included studies. Only one RCT was found; most studies were case-series lacking statistical analysis. RD was common in post-partum women. Antepartum activity level may have a protective effect on RD and exercise may improve post-partum symptoms of RD. Repair was done during abdominoplasty or laparoscopically. The patient-satisfaction was high and long-term recurrence was reported by one study, while five reported no recurrence. Overall major complications were few, while minor complications were primarily seroma and wound complications. RD is by itself not a true hernia and, therefore, not associated with the risk of strangulation. Repair is mostly done due to cosmetic reasons. The condition does not necessarily require repair, and conservative management may be an alternative. If done, the protrusion of the abdomen, rather than the diastasis itself should influence the decision of repair. It is recommended that future studies use the established classifications (e.g. Beer, Rath, or Nahas) when reporting RD and long-term outcome of treatment. Comparison of surgical techniques and studies that address and compare conservative management with surgery are needed.

  14. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    PubMed Central

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  15. Out-of-plane properties

    NASA Technical Reports Server (NTRS)

    Jackson, Wade C.; Portanova, Marc A.

    1995-01-01

    This paper summarizes three areas of research which were performed to characterize out-of-plane properties of composite materials. In the first investigation, a series of tests was run to characterize the through-the-thickness tensile strength for a variety of composites that included 2D braids, 2D and 3D weaves, and prepreg tapes. A new test method based on a curved beam was evaluated. Failures were significantly different between the 2D materials and the 3D weaves. The 2D materials delaminated between layers due to out-of-plane tensile stresses while the 3D weaves failed due to the formation of radial cracks between the surface plies caused by high circumferential stresses along the inner radius. The strength of the 2D textile composites did not increase relative to the tapes. Final failure in the 3D weaves was caused by a circumferential crack similar to the 2D materials and occurred at a lower bending moment than in other materials. The early failures in the 3D weaves were caused by radial crack formation rather than a low through-the-thickness strength. The second investigation focused on the development of a standard impact test method to measure impact damage resistance. The only impact tests that currently exist are compression after impact (CAI) tests which incorporate elements of both damage resistance and damage tolerance. A new impact test method is under development which uses a quasi-static indentation (QSI) test to directly measure damage resistance. Damage resistance is quantified in terms of the contact force to produce a unit of damage where a metric for damage may be area in C-scan, depth of residual dent , penetration, damage growth, etc. A final draft of an impact standard that uses a QSI test method will be presented to the ASTM Impact Task Group on impact. In the third investigation, the impact damage resistance behavior of a variety of textile materials was studied using the QSI test method. In this study, the force where large damage

  16. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass vascular catheter, cannula... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to...

  17. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass vascular catheter, cannula... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to...

  18. Retrieval of impacted broken balloon by balloon inflation in guiding catheter.

    PubMed

    Mehta, Vimal; Pandit, Bhagya Narayan; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay; Tyagi, Sanjay

    2014-07-01

    Broken catheter fragment in a coronary artery during percutaneous coronary angioplasty is a rare complication. It can result in serious problems as a result of thrombus formation and embolization of broken fragment. We report an unusual complication of a broken balloon catheter during angioplasty, which was successfully retrieved by balloon inflation in guiding catheter technique.

  19. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    PubMed

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  20. Superior vena cava syndrome with central venous catheter for chemotherapy treated successfully with fibrinolysis.

    PubMed

    Guijarro Escribano, J F; Antón, R F; Colmenarejo Rubio, A; Sáenz Cascos, L; Sainz González, F; Alguacil Rodríguez, R

    2007-03-01

    Recently, there has been an increase in the number of cases of superior vena cava (SVC) syndrome associated with chronic indwelling central venous catheters. Fibrinolytic therapy and endovascular treatment are currently achieving good results. We present a case history of a patient with SVC with a catheter used for chemotherapy, which was successfully treated with catheter-directed (intraclot) infusion thrombolytic therapy with urokinase.

  1. Long-Term Outcomes of Single-Port Laparoscopic Placement of Peritoneal Dialysis Catheter.

    PubMed

    Pan, Alan; Poi, Mun J; Matos, Jesus; Jiang, Jenny S; Kfoury, Elias; Echeverria, Angela; Bechara, Carlos F; Lin, Peter H

    2016-07-01

    Laparoscopic insertion of peritoneal dialysis (PD) catheter has become a preferred method compared to the traditional open technique for PD catheter insertion. We retrospectively report the outcome of 1-port laparoscopic placement PD catheters in our institution. A total of 263 patients with end-stage renal disease who underwent single-trocar laparoscopic PD catheter insertion during a recent 6-year period were reviewed. Laparoscopic technique involves introducing a PD catheter over a stiff guidewire into the abdominal cavity through a 10-mm laparoscopic port. Pertinent clinical variables, procedural complications, and follow-up outcome were analyzed. There were 182 men and 81 women. The mean age was 56 years. Technical success was 95.8%. Catheter occlusion was the most common early complications (<6 months) that occurred in 4 (1.5%) patients. Late complications (> 6 months) including catheter occlusion, cuff extrusion, catheter leakage, catheter migration, infection, and hernia occurred in 5 patients (1.9%), 2 patients (0.8%), 3 patients (1.1%), 3 patients (1.1%), 6 patients (2.3%), and 4 patients (1.5), respectively. Mean follow-up time was 39 ± 18 months. Catheter survival rate at 1, 2, 3, 4, and 5 years was 96%, 94%, 90%, 85%, and 82%, respectively. Laparoscopic PD catheter implantation via a single-trocar utilizing a stiff guidewire technique is feasible and safe. This method can result in low complication and high catheter survival rate. © The Author(s) 2016.

  2. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal.

    PubMed

    Urbanetto, Janete de Souza; Peixoto, Cibelle Grassmann; May, Tássia Amanda

    2016-08-08

    to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC) and following their removal - (post-infusion phlebitis) in hospitalized adults. a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective. investigar a incidência de flebites e a associação de fatores de risco com a sua ocorrência durante o uso e após a retirada do cateter intravenoso periférico - CIP (Flebite pós-infusão) em adultos hospitalizados. estudo de coorte com 171 pacientes com CIP, totalizando 361 punções. Foram coletadas variáveis sociodemográficas e relacionadas ao cateter. Análise estatística descritiva e analítica. dos pacientes, 51,5% eram homens e a média de idade foi de 56,96 anos. A incidência de flebites durante o uso do CIP foi de 1,25% e a pós-infusão foi de 1,38%. Associou-se à flebite durante o uso do CIP ao tempo de permanência do

  3. A Collaborative Knowledge Plane for Autonomic Networks

    NASA Astrophysics Data System (ADS)

    Mbaye, Maïssa; Krief, Francine

    Autonomic networking aims to give network components self-managing capabilities. Several autonomic architectures have been proposed. Each of these architectures includes sort of a knowledge plane which is very important to mimic an autonomic behavior. Knowledge plane has a central role for self-functions by providing suitable knowledge to equipment and needs to learn new strategies for more accuracy.However, defining knowledge plane's architecture is still a challenge for researchers. Specially, defining the way cognitive supports interact each other in knowledge plane and implementing them. Decision making process depends on these interactions between reasoning and learning parts of knowledge plane. In this paper we propose a knowledge plane's architecture based on machine learning (inductive logic programming) paradigm and situated view to deal with distributed environment. This architecture is focused on two self-functions that include all other self-functions: self-adaptation and self-organization. Study cases are given and implemented.

  4. On plane submerged laminar jets

    NASA Astrophysics Data System (ADS)

    Coenen, Wilfried; Sanchez, Antonio L.

    2016-11-01

    We address the laminar flow generated when a developed stream of liquid of kinematic viscosity ν flowing along channel of width 2 h discharges into an open space bounded by two symmetric plane walls departing from the channel rim with an angle α 1 . Attention is focused on values of the jet volume flux 2 Q such that the associated Reynolds number Re = Qh / ν is of order unity. The formulation requires specification of the boundary conditions far from the channel exit. If the flow is driven by the volume flux, then the far-field solution corresponds to Jeffery-Hamel self-similar flow. However, as noted by Fraenkel (1962), such solutions exist only for α <129o in a limited range of Reynolds numbers 0 <=Re <=Rec (α) (e.g. Rec = 1 . 43 for α = π / 2). It is reasoned that an alternative solution, driven by a fraction of the momentum flux of the feed stream, may also exist for all values of Re and α, including a near-centerline Bickley jet, a surrounding Taylor potential flow driven by the jet entrainment, and a Falkner-Skan near-wall boundary layer. Numerical integrations of the Navier-Stokes equations are used to ascertain the existence of these different solutions.

  5. Galactic plane gamma-radiation

    NASA Technical Reports Server (NTRS)

    Hartman, R. C.; Kniffen, D. A.; Thompson, D. J.; Fichtel, C. E.; Ogelman, H. B.; Tumer, T.; Ozel, M. E.

    1979-01-01

    Analysis of the SAS 2 data together with the COS B results shows that the distribution of galactic gamma-radiation has several similarities to that of other large-scale tracers of galactic structure. The radiation is primarily confined to a thin disc which exhibits offsets from b = 0 degrees similar to warping at radio frequencies. The principal distinction of the gamma-radiation is a stronger contrast in intensity between the region from 310 to 45 degrees in longitude and the regions away from the center that can be attributed to a variation in cosmic-ray density as a function of position in Galaxy. The diffuse galactic gamma-ray energy spectrum shows no significant variation in direction, and the spectrum seen along the plane is the same as that for the galactic component of the gamma-radiation at high altitudes. The uniformity of the galactic gamma-ray spectrum, the smooth decrease in intensity as a function of altitude, and the absence of any galactic gamma-ray sources at high altitudes indicate a diffuse origin for bulk of the galactic gamma-radiation rather than a collection of localized sources.

  6. Radioactivity in the galactic plane

    NASA Technical Reports Server (NTRS)

    Walraven, G. D.; Haymes, R. C.

    1976-01-01

    The paper reports the detection of a large concentration of interstellar radioactivity during balloon-altitude measurements of gamma-ray energy spectra in the band between 0.02 and 12.27 MeV from galactic and extragalactic sources. Enhanced counting rates were observed in three directions towards the plane of the Galaxy; a power-law energy spectrum is computed for one of these directions (designated B 10). A large statistical deviation from the power law in a 1.0-FWHM interval centered near 1.16 MeV is discussed, and the existence of a nuclear gamma-ray line at 1.15 MeV in B 10 is postulated. It is suggested that Ca-44, which emits gamma radiation at 1.156 MeV following the decay of radioactive Sc-44, is a likely candidate for this line, noting that Sc-44 arises from Ti-44 according to explosive models of supernova nucleosynthesis. The 1.16-MeV line flux inferred from the present data is shown to equal the predicted flux for a supernova at a distance of approximately 3 kpc and an age not exceeding about 100 years.

  7. Reflections on the Hyperbolic Plane

    NASA Astrophysics Data System (ADS)

    Lecian, Orchidea Maria

    2013-12-01

    The most general solution to the Einstein equations in 4 = 3 + 1 dimensions in the asymptotic limit close to the cosmological singularity under the BKL (Belinskii-Khalatnikov-Lifshitz) hypothesis can be visualized by the behavior of a billiard ball in a triangular domain on the Upper Poincaré Half Plane (UPHP). The billiard system (named "big billiard") can be schematized by dividing the successions of trajectories according to Poincaré return map on the sides of the billiard table, according to the paradigms implemented by the BKL investigation and by the CB-LKSKS (Chernoff-Barrow-Lifshitz-Khalatnikov-Sinai-Khanin-Shchur) one. Different maps are obtained, according to different symmetry-quotienting mechanisms used to analyze the dynamics. In the inhomogeneous case, new structures have been uncovered, such that, in this framework, the billiard table (named "small billiard") consists of 1/6 of the previous one. The connections between the symmetry-quotienting mechanisms are further investigated on the UPHP. The relation between the complete billiard and the small billiard are also further explained according to the role of Weyl reflections. The quantum properties of the system are sketched as well, and the physical interpretation of the wave function is further developed. In particular, a physical interpretation for the symmetry-quotienting maps is proposed.

  8. Intraluminal pneumatic lithotripsy for the removal of encrusted urinary catheters.

    PubMed

    Canby-Hagino, E D; Caballero, R D; Harmon, W J

    1999-12-01

    Urologists frequently treat patients requiring long-term urinary drainage with a percutaneous nephrostomy tube or ureteral stent. When such tubes are neglected and become encrusted, removal challenges even experienced urologists. We describe a new, minimally invasive technique for safely and rapidly removing encrusted, occluded tubes using the Swiss Lithoclast pneumatic lithotriptor. Patients presenting with an encrusted urinary catheter were evaluated by excretory urography for renal function and obstruction. Gentle manual extraction of the tube was attempted, followed by traditional extracorporeal shock wave lithotripsy and/or ureteroscopy. When the tube was not extracted, patients were then treated with intraluminal insertion of a pneumatic lithotripsy probe. One patient presented with an encrusted, occluded nephrostomy tube and 2 had an encrusted, occluded, indwelling ureteral stent. None was removed by manual traction. Intraluminal encrustations prevented the pigtail portions of these tubes from uncoiling and removal. In each case a pneumatic lithotripsy probe was inserted into the lumen of the catheter and advanced in a jackhammer-like fashion. This technique resulted in disruption of the intraluminal encrustations and straightening of the tubes so that they were removed in an atraumatic manner. Intraluminal pneumatic lithotripsy is a safe, easy and rapid technique for removing encrusted urinary catheters. It is unique in that the pneumatic lithotripsy probe functions in an aqueous and nonaqueous environment, and dislodges intraluminal calcifications. We recommend its use as first line treatment for removing encrusted urinary catheters.

  9. Changing profile of excimer laser coronary angioplasty: refinements in catheters

    NASA Astrophysics Data System (ADS)

    Bittl, John A.

    1994-07-01

    During more than five years of investigation with excimer laser angioplasty, several changes have been made in patient selection and laser catheters. It is unclear, however, whether these changes have improved the outcome of excimer laser angioplasty. A total of 2041 patients underwent treatment with excimer laser coronary angioplasty for 2324 lesions with clinical success in 89%, ischemic complications in 7.5%, and vessel perforation in 2.1%. When the entire 5-year period of investigation was divided into four discrete phases, as defined by the successive release of improved laser catheters (prototype, flexible, extremely flexible, and eccentric), clinical success was seen to improve from 86% to 95% (p<0.001) despite the increased incidence of advanced age (pequals0.01) and unstable angina (p<0.001). Multivariable analysis identified improved laser catheters, saphenous vein graft lesions, and unclarified stenoses as predictors of favorable outcome. Operator experience was associated with decreased complications. Reduced catheter size relative to vessel size was associated with decreased risk of vessel perforation. Thus, refinements in patient selection and in laser technique have been associated with enhanced safety and efficacy of excimer laser angioplasty.

  10. [Complications of double j catheters and their endourological management].

    PubMed

    Pérez-Fentes, D

    2016-10-01

    The insertion of a double J catheter (DJ) has widespread, becoming a usual procedure and standard of care in urology. Despite its relative simplicity it is not free from intraoperative risks or problems during the weeks after the implant. Conversely, despite great advances in design of these catheters the ideal material has not been discovered yet, one that is perfectly biocompatible with urine and avoids completely the advent of complications. The range of problems associated with DJs is variable: from mild self-limited dysuria or hematuria to more complex situations with higher risk, such as catheter migration, complete calcification, breakage, obstruction and renal unit loss. The treatment of theses complications must combine maximal efficacy for their resolution with the least possible surgical aggression. Accordingly, the different options of endourological approach become very important and they are the cornerstone for the treatment of the complications associated with ureteral catheters. The objective of this review is to present the main complications derived from the insertion of a DJ, their diagnosis, prevention and treatment, focusing mainly in the different endourological techniques.

  11. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steerable catheter control system. 870.1290 Section 870.1290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable...

  12. 21 CFR 870.1230 - Fiberoptic oximeter catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fiberoptic oximeter catheter. 870.1230 Section 870.1230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1230 Fiberoptic oximeter...

  13. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continuous flush catheter. 870.1210 Section 870.1210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush...

  14. 21 CFR 876.5030 - Continent ileostomy catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continent ileostomy catheter. 876.5030 Section 876.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5030 Continent ileostomy...

  15. Bi-layer sandwich film for antibacterial catheters

    PubMed Central

    Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly(p-xylylene). This top layer is mainly designed to release a controlled amount of Ag+ ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens’ reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin’s pot and the principle of Le Chatelier. PMID:29046846

  16. Bi-layer sandwich film for antibacterial catheters.

    PubMed

    Franz, Gerhard; Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly( p -xylylene). This top layer is mainly designed to release a controlled amount of Ag + ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens' reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin's pot and the principle of Le Chatelier.

  17. Factors confounding impedance catheter volume measurements in vitro.

    PubMed

    Bielefeld, M R; Cabreriza, S E; Spotnitz, H M

    1993-06-01

    The impedance catheter allows continuous measurement of ventricular volume. External influences have been described as causing parallel shifts in impedance-measured volumes; however, factors affecting impedance measurements in a nonparallel manner have not been fully characterized. Accordingly, an impedance catheter was placed inside a latex balloon into which known volumes of normal saline solution were injected. Conductive and nonconductive materials were individually placed within the balloon. Impedance was measured with materials touching (T) or not touching (NT) the catheter. Impedance-measured volumes were plotted versus actual volumes. Compared with the line of identity (LID), a statistical difference (p < 0.05) was found in the slopes in the presence of metallic objects only. These included a pacing lead (T, NT) (mT = 1.32m mNT = 1.29 versus mLID = 1.00), titanium (T) (mT = 1.68 versus mLID = 1.00), and aluminum (NT) (mNT = 0.72 versus mLID = 1.00). These changes in slope indicate nonparallel effects on impedance that confound the ability of the impedance catheter to determine volumes in vitro. These observations imply that serial calibration of both the slope constant (alpha) and the intercept (parallel conductance) of impedance may be