Sample records for abdominis plane catheters

  1. Subcostal Transverse Abdominis Plane Block for Acute Pain Management: A Review.

    PubMed

    Soliz, Jose M; Lipski, Ian; Hancher-Hodges, Shannon; Speer, Barbra Bryce; Popat, Keyuri

    2017-10-01

    The subcostal transverse abdominis plane (SCTAP) block is the deposition of local anesthetic in the transverse abdominis plane inferior and parallel to the costal margin. There is a growing consensus that the SCTAP block provides better analgesia for upper abdominal incisions than the traditional transverse abdominis plane block. In addition, when used as part of a four-quadrant transverse abdominis plane block, the SCTAP block may provide adequate analgesia for major abdominal surgery. The purpose of this review is to discuss the SCTAP block, including its indications, technique, local anesthetic solutions, and outcomes.

  2. Transversus Abdominis Plane Blocks with Single-Dose Liposomal Bupivacaine in Conjunction with a Nonnarcotic Pain Regimen Help Reduce Length of Stay following Abdominally Based Microsurgical Breast Reconstruction.

    PubMed

    Jablonka, Eric M; Lamelas, Andreas M; Kim, Julie N; Molina, Bianca; Molina, Nathan; Okwali, Michelle; Samson, William; Sultan, Mark R; Dayan, Joseph H; Smith, Mark L

    2017-08-01

    Side effects associated with use of postoperative narcotics for pain control can delay recovery after abdominally based microsurgical breast reconstruction. The authors evaluated a nonnarcotic pain control regimen in conjunction with bilateral transversus abdominis plane blocks on facilitating early hospital discharge. A retrospective analysis was performed of consecutive patients who underwent breast reconstruction using abdominally based free flaps, with or without being included in a nonnarcotic protocol using intraoperative transversus abdominis plane blockade. During this period, the use of locoregional analgesia evolved from none (control), to continuous bupivacaine infusion transversus abdominis plane and catheters, to single-dose transversus abdominis plane blockade with liposomal bupivacaine solution. Demographic factors, length of stay, inpatient opioid consumption, and complications were reported for all three groups. One hundred twenty-eight consecutive patients (182 flaps) were identified. Forty patients (62 flaps) were in the infusion-liposomal bupivacaine group, 48 (66 flaps) were in the single-dose blockade-catheter group, and 40 (54 flaps) were in the control group. The infusion-liposomal bupivacaine patients had a significantly shorter hospital stay compared with the single-dose blockade-catheter group (2.65 ± 0.66 versus 3.52 ± 0.92 days; p < 0.0001) and the control group (2.65 ± 0.66 versus 4.05 ± 1.26 days; p < 0.0001). There was no significant difference in flap loss or major complications among groups. When used as part of a nonnarcotic postoperative pain regimen, transversus abdominis plane blocks performed with single injections of liposomal bupivacaine help facilitate early hospital discharge after abdominally based microsurgical breast reconstruction. A trend toward consistent discharge by postoperative day 2 was seen. This could result in significant cost savings for health care systems. Therapeutic, III.

  3. [Subcostal transversus abdominis plane block can improve analgesia after laparoscopic cholecystectomy].

    PubMed

    Vrsajkov, Vladimir; Mančić, Nedjica; Mihajlović, Dunja; Milićević, Suzana Tonković; Uvelin, Arsen; Vrsajkov, Jelena Pantić

    After laparoscopic cholecystectomy, patients have moderate pain in the early postoperative period. Some studies shown beneficial effects of subcostal transversus abdominis plane block on reducing this pain. Our goal was to investigate influence of subcostal transversus abdominis plane block on postoperative pain scores and opioid consumption. We have randomized 76 patients undergoing laparoscopic cholecystectomy to receive either subcostal transversus abdominis plane block (n=38) or standard postoperative analgesia (n=38). First group received bilateral ultrasound guided subcostal transversus abdominis plane block with 20mL of 0.33% bupivacaine per side before operation and tramadol 1mg.kg -1 IV for pain breakthrough (≥6). Second group received after operation tramadol 1mg.kg -1 /6h as standard hospital analgesia protocol. Both groups received acetaminophen 1g/8h IV and metamizole 2.5g/12h. Pain at rest was recorded for each patient using NR scale (0-10) in period of 10min, 30min, 2h, 4h, 8h, 12h and 16h after the surgery. We obtained no difference between groups according age, weight, intraoperative fentanyl consumption and duration of surgery. Subcostal transversus abdominis plane block significantly reduced postoperative pain scores compared to standard analgesia in all periods after surgery. Tramadol consumption was significantly lower in the subcostal transversus abdominis plane (24.29±47.54g) than in the standard analgesia group (270.2±81.9g) (p=0.000). Our results show that subcostal transversus abdominis plane block can provide superior postoperative analgesia and reduction in opioid requirements after laparoscopic cholecystectomy. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. Colostomy with Transversus Abdominis Plane Block

    PubMed Central

    Tekelioğlu, Ümit Yaşar; Demirhan, Abdullah; Şit, Mustafa; Kurt, Adem Deniz; Bilgi, Murat; Koçoğlu, Hasan

    2015-01-01

    Transversus abdominis plane (TAP) block is one of the abdominal field block. The TAP block is used for both anaesthetic management and post-operative pain therapy in lower abdominal surgery. TAP block is a procedure in which local anaesthetic agents are applied to the anatomic neurofacial space between the internal oblique and the transversus abdominis muscle. TAP block is a good method for post-operative pain control as well as allows for short operations involving the abdominal area. In this article, a case of colostomy under TAP block is presented. PMID:27366540

  5. Transversus abdominis plane block reduces morphine consumption in the early postoperative period following microsurgical abdominal tissue breast reconstruction: a double-blind, placebo-controlled, randomized trial.

    PubMed

    Zhong, Toni; Ojha, M; Bagher, Shaghayegh; Butler, Kate; Srinivas, Coimbatore; McCluskey, Stuart A; Clarke, Hance; O'Neill, Anne C; Novak, Christine B; Hofer, Stefan O P

    2014-11-01

    The analgesic efficacy of the transversus abdominis plane peripheral nerve block following abdominal tissue breast reconstruction has not been studied in a randomized controlled trial. The authors conducted a double-blind, placebo-controlled, 1:1 allocation, two-arm parallel group, superiority design, randomized controlled trial in patients undergoing microsurgical abdominally based breast reconstruction. Intraoperatively, epidural catheters were inserted under direct vision through the triangle of Petit on both sides of the abdomen into the transversus abdominis plane just before rectus fascial closure. Patients received either bupivacaine (study group) or saline (placebo group) through the catheters for 2 postoperative days. All patients received hydromorphone by means of a patient-controlled analgesic pump. The primary outcome was the difference in the parenteral opioid consumption on each postoperative day between the groups. The secondary outcome measures included the following: total in-hospital opioid; antinausea medication; pain, nausea, and sedation scores; Quality of Recovery Score; time to ambulation; and hospital stay duration. Between September of 2011 and June of 2013, 93 patients were enrolled: 49 received bupivacaine and 44 received saline. There were 11 postoperative complications (13 percent); none were related to the catheter. Primary outcomes were completed by 85 of 93 patients (91.3 percent); the mean parenteral morphine consumption was significantly reduced on postoperative day 1 in the bupivacaine group (20.7±20.1 mg) compared with 30.0±19.1 mg in the control group (p=0.02). There were no significant differences in secondary outcomes. Following abdominally based breast reconstruction, transversus abdominis plane peripheral nerve block is safe and significantly reduces morphine consumption in the early postoperative period. Therapeutic, II.

  6. Four quadrant transversus abdominis plane block and continuous transversus abdominis plane analgesia: a 3-year prospective audit in 124 patients.

    PubMed

    Niraj, G; Kelkar, Aditi; Hart, Elaine; Kaushik, Vipul; Fleet, Danny; Jameson, John

    2015-11-01

    Transversus abdominis plane (TAP) blocks have been reported to be an effective method of providing analgesia after abdominal surgery. To perform a prospective audit on the effectiveness of a novel technique of providing continuous transversus abdominis plane (TAP) analgesia in patients undergoing emergency and elective abdominal surgery. Prospective single center audit over a 3-year period. University hospital. One hundred twenty-four American Society of Anesthesiologists I to IV adult patients presenting for elective as well as emergency abdominal surgery in whom epidural analgesia was contraindicated or refused. Four quadrant TAP blocks and continuous TAP analgesia. Numerical rating scale pain scores at rest and on coughing, nausea scores, satisfaction scores, complications, frequency of analgesia failure, therapeutic failure with continuous TAP analgesia and opioid consumption. One hundred twenty-four patients who received continuous TAP analgesia were audited. This included 34 patients for elective open surgery, 36 patients for emergency laparotomy, and 54 patients who underwent elective laparoscopic colorectal surgery. Surgical incision was within the dermatomal limit of the block in 70% of the patients (88/124). Therapeutic failure with the technique was 10%. Frequency of analgesic failure over the 48-hour period was none in 39% and below 5 episodes in 57%. Four quadrant transversus abdominis plane blocks and continuous TAP analgesia is an effective technique for providing postoperative analgesia after abdominal surgery. It has the potential to be used as a sole analgesic technique when the surgical incision is within its dermatomal limit. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Dexmedetomidine in a surgically inserted catheter for transversus abdominis plane block in donor hepatectomy: A prospective randomized controlled study.

    PubMed

    Aboelela, Mohamed Adel; Kandeel, Al-Refaey; Elsayed, Usama; Elmorshedi, Mohamed; Elsarraf, Waleed; Elsayed, Eman; Elgawalby, Ahmed; Sultan, Ahmed Mohamed; Wahab, Mohamed Abdel; Yassen, Amr

    2018-01-01

    Transversus abdominis plane (TAP) block is a promising technique for analgesia after abdominal surgery. This prospective, randomized controlled trial assessed the effect of adding dexmedetomidine to bupivacaine in TAP block for donor hepatectomy. We hypothesized that this would improve postoperative morphine consumption and reduce analgesia related complication and inflammation. A total of 50 donor hepatectomy were enrolled in this study. Patients divided into two equal groups according to drugs used for TAP block. Group (B) received 20 ml of bupivacaine hydrochloride 0.25%, Group (BD) received 20 ml of bupivacaine hydrochloride 0.25% and 0.3 μg/kg dexmedetomidine, on both sides at the end of surgery and every 8 h for 48 h at right side only through inserted catheter. Primary outcome objective was morphine consumption at first 72 h. Secondary outcome objectives were morphine requirement, numbers of intake, time to first intake, pain score numerical analog scale (NAS), postoperative analgesia related complications, recovery of intestinal motility, and inflammatory markers. Data were analyzed, rescue morphine analgesia was significantly lower in (BD) group compared with (B) groups as considering total morphine consumption (B 4 ± 1.9, BD 1.5 ± 0.5, P = 0.03), numbers of morphine intake ( P = 0.04), morphine requirement ( P = 0.03), and first time of analgesia intake ( P = 0.04). NAS was significantly lower in group (BD) compared with group (B) group in the first 12 h (NAS 0 - P = 0.001, NAS 1 - P = 0.03). Adding dexmedetomidine improved gut motility, first oral intake without detectable anti-inflammatory effect. Adding dexmedetomidine to bupivacine in a surgically inserted catheter for TAP block in donor hepatectomy reduced morphine consumption without detectable anti-inflammatory effect.

  8. Comparison of analgesic efficacy of four-quadrant transversus abdominis plane (TAP) block and continuous posterior TAP analgesia with epidural analgesia in patients undergoing laparoscopic colorectal surgery: an open-label, randomised, non-inferiority trial.

    PubMed

    Niraj, G; Kelkar, A; Hart, E; Horst, C; Malik, D; Yeow, C; Singh, B; Chaudhri, S

    2014-04-01

    Posterior transversus abdominis plane blocks have been reported to be an effective method of providing analgesia after lower abdominal surgery. We compared the efficacy of a novel technique of providing continuous transversus abdominis plane analgesia with epidural analgesia in patients on an enhanced recovery programme following laparoscopic colorectal surgery. A non-inferiority comparison was used. Adult patients undergoing elective laparoscopic colorectal surgery were randomly assigned to receive continuous transversus abdominis plane analgesia (n = 35) vs epidural analgesia (n = 35), in addition to a postoperative analgesic regimen comprising regular paracetamol, regular diclofenac and tramadol as required. Sixty-one patients completed the study. The transversus group received four-quadrant transversus abdominis plane blocks and bilateral posterior transversus abdominis plane catheters that were infused with levobupivacaine 0.25% for 48 h. The epidural group received an infusion of bupivacaine and fentanyl. The primary outcome measure was visual analogue scale pain score on coughing at 24 h after surgery. We found no significant difference in median (IQR [range]) visual analogue scores during coughing at 24 h between the transversus group 2.5 (1.0-3.0 [0-5.5]) and the epidural group 2.5 (1.0-5.0 [0-6.0]). The one-sided 97.5% CI was a 0.0 (∞-1.0) difference in means, establishing non-inferiority. There were no significant differences between the groups for tramadol consumption. Success rate was 28/30 (93%) in the transversus group vs 27/31 (87%) in the epidural group. Continuous transversus abdominis plane infusion was non-inferior to epidural infusion in providing analgesia after laparoscopic colorectal surgery. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  9. A comparison of plasma levobupivacaine concentrations following transversus abdominis plane block and rectus sheath block.

    PubMed

    Yasumura, R; Kobayashi, Y; Ochiai, R

    2016-05-01

    Levobupivacaine is commonly used as the local anaesthetic of choice in peripheral nerve blocks, but its pharmacokinetics have not been fully investigated. We compared the changes in plasma concentrations of levobupivacaine following transversus abdominis plane block and rectus sheath block. Fifty woman undergoing laparoscopy were randomly allocated to receive either a transversus abdominis plane block or an rectus sheath block. In both groups, 2.5 mg.kg(-1) levobupivacaine was administered, and blood samples were obtained 15 min, 30 min, 60 min and 120 min after injection. The mean maximum plasma concentration (Cmax) and mean time to reach Cmax (Tmax) as determined by non-linear regression analysis were 1.05 μg.ml(-1) and 32.4 min in the transversus abdominis plane group and 0.95 μg.ml(-1) and 60.9 min in the rectus sheath group, respectively. The plasma concentration of levobupivacaine peaked earlier in the transversus abdominis plane group than in the rectus sheath group and the maximum plasma concentration depended on the dose administered but not the procedure. © 2016 The Association of Anaesthetists of Great Britain and Ireland.

  10. [The effects of transversus abdominis plane block on analgesic and anesthetic consumption during total abdominal hysterectomy: a randomized controlled study].

    PubMed

    Karaman, Tugba; Ozsoy, Asker Zeki; Karaman, Serkan; Dogru, Serkan; Tapar, Hakan; Sahin, Aynur; Dogru, Hatice; Suren, Mustafa

    A transversus abdominis plane block is a peripheral block method that has been used successfully for pain relief after total abdominal hysterectomy. However, the effects of the combination of the transversus abdominis plane block and general anesthesia on analgesic and anesthetic requirements remain unclear. This randomized placebo-controlled study is aimed to evaluate the effects of transversus abdominis plane block on analgesic and anesthetic consumption during total abdominal hysterectomy under general anesthesia. Sixty-six women undergoing total abdominal hysterectomy were randomized into two groups to receive general anesthesia alone (control group) or with transversus abdominis plane block using 20mL of 0.25% bupivacaine (transversus abdominis plane group). Intraoperative remifentanil and sevoflurane consumption were recorded. We also evaluated the postoperative pain, nausea, quality of recovery scores and rescue analgesic requirement during postoperative 24hours. The total remifentanil and sevoflurane consumption is significantly lower in transversus abdominis plane group; respectively mean (SD) 0.130 (0.25) vs. 0.094 (0.02) mcg.kg -1 .min -1 ; p<0.01 and 0.295 (0.05) vs. 0.243 (0.06) mL.min -1 ; p<0.01. In the postoperative period, pain scores were significantly reduced in transversus abdominis plane group soon after surgery; median (range) 6 (2-10) vs. 3 (0-5); p<0.001, at 2h (5 [3-9] vs. 2.5 [0-6]; p<0.001), at 6h (4 [2-7] vs. 3[0-6], p<0.001), at 12h (3.5 [1-6] vs. 2 [1-5]; p=0.003). The patients in the transversus abdominis plane group had significantly higher QoR-40 scores 190.5 (175-197) vs. 176.5 (141-187); p<0.001). Combining transversus abdominis plane block with general anesthesia can provide reduced opioid and anesthetic consumption and can improve postoperative pain and quality of recovery scores in patients undergoing total abdominal hysterectomy. Copyright © 2018 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All

  11. A randomised trial of the analgesic efficacy of ultrasound-guided transversus abdominis plane block after caesarean delivery under general anaesthesia.

    PubMed

    Tan, Terry T; Teoh, Wendy H L; Woo, David C M; Ocampo, Cecilia E; Shah, Mukesh K; Sia, Alex T H

    2012-02-01

    Previous studies examining the efficacy of transversus abdominis plane block after caesarean section have mostly been in parturients under spinal anaesthesia. We postulated that the advantage of performing transversus abdominis plane block after caesarean section might be even more obvious after general anaesthesia, resulting in reduced 24-h consumption of morphine. DESIGN, SETTING, PATIENTS AND INTERVENTIONS: In this single centre, randomised double-blind controlled trial, 40 women who underwent caesarean delivery under general anaesthesia were allocated randomly to receive a transversus abdominis plane block or no block. In those who received the block, 20 ml of levobupivacaine 2.5 mg ml was deposited bilaterally into the transversus abdominis plane under ultrasound guidance using a Sonosite Titan (SonoSite, Bothell, Washington, USA) 7-13 MHz linear transducer at the end of surgery when the patient was still anaesthetised. We recorded patient-controlled intravenous morphine use for 24 h, pain scores at rest and activity, sedation, nausea and vomiting, use of antiemetic medication and overall maternal satisfaction. The primary outcome was 24-h morphine consumption. Patients who received the transversus abdominis plane block used significantly less morphine in 24 h than those in the control group [12.3 (2.6) vs. 31.4 mg (3.1), P<0.001) and had higher satisfaction scores [16 (80%) vs. 5 (25%), P = 0.012). There were no differences between groups in the visual analogue pain scores, sedation level, nausea and vomiting or the use of antiemetic medication. Ultrasound-guided transversus abdominis plane block reduced morphine consumption following caesarean section under general anaesthesia, with increased maternal satisfaction.

  12. Comparison of analgesic efficacy of subcostal transversus abdominis plane blocks with epidural analgesia following upper abdominal surgery.

    PubMed

    Niraj, G; Kelkar, A; Jeyapalan, I; Graff-Baker, P; Williams, O; Darbar, A; Maheshwaran, A; Powell, R

    2011-06-01

    Subcostal transversus abdominis plane (TAP) catheters have been reported to be an effective method of providing analgesia after upper abdominal surgery. We compared their analgesic efficacy with that of epidural analgesia after major upper abdominal surgery in a randomised controlled trial. Adult patients undergoing elective open hepatobiliary or renal surgery were randomly allocated to receive subcostal TAP catheters (n=29) or epidural analgesia (n=33), in addition to a standard postoperative analgesic regimen comprising of regular paracetamol and tramadol as required. The TAP group patients received bilateral subcostal TAP catheters and 1 mg.kg(-1) bupivacaine 0.375% bilaterally every 8 h. The epidural group patients received an infusion of bupivacaine 0.125% with fentanyl 2 μg.ml(-1) . The primary outcome measure was visual analogue pain scores during coughing at 8, 24, 48 and 72 h after surgery. We found no significant differences in median (IQR [range]) visual analogue scores during coughing at 8 h between the TAP group (4.0 (2.3-6.0 [0-7.5])) and epidural group (4.0 (2.5-5.3) [0-8.5])) and at 72 h (2.0 (0.8-4.0 [0-5]) and 2.5 (1.0-5.0 [0-6]), respectively). Tramadol consumption was significantly greater in the TAP group (p=0.002). Subcostal TAP catheter boluses may be an effective alternative to epidural infusions for providing postoperative analgesia after upper abdominal surgery. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  13. Efficacy of ultrasound-guided transversus abdominis plane block in laparoscopic hysterectomy. Clinical trial.

    PubMed

    Guardabassi, D S; Lupi, S; Agejas, R; Allub, J M; García-Fornari, G

    2017-05-01

    Transversus abdominis plane block is a regional anaesthesia technique that has proven to be effective for postoperative pain reduction in different abdominal surgical procedures. This study evaluated its efficacy on post laparoscopic hysterectomy pain intensity and analgesic consumption. Randomized controlled trial which included 40 patients scheduled for laparoscopic hysterectomy, enrolled in 2 groups: transversus abdominis plane block+systemic analgesia (Group 1; n=20), versus systemic analgesia (Group 2; n=20). Opioid consumption within the first 24 postoperative hours, pain intensity scores at 60min, 2, 8 and 24h after surgery, adverse events related to systemic analgesia and time to hospital discharge were evaluated and registered. We found no differences between both groups in opioid consumption (10mg vs. 7mg; P=.2) and pain scores (NVS) within the first 24 postoperative hours, at 60min (3 vs. 5; P=.65), 120min (0 vs. 2; P=.15), 8 and 24h (0 vs. 0; P>.50) for the last 2 points in time analysed. Adverse events related to medication and time to hospital discharge showed similar results. Adding a transversus abdominis plane block technique to opioid PCA does not seem to improve postoperative pain management in laparoscopic hysterectomy. Patient preparation time and costs could be incremented and complications (although rare) related to the technique could appear. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Comparison of ultrasound guided transversus abdominis plane block versus local wound infiltration for post operative analgesia in patients undergoing gynaecological surgery under general anaesthesia.

    PubMed

    Ranjit, S; Shrestha, S K

    2014-01-01

    Transversus abdominis plane block has been recently developed as a part of multimodal post operative analgesic techniques. We compared the analgesic efficacy of this technique with local bupivacaine infiltration in patients undergoing gynaecological surgeries with pfannenstiel incision and lower midline incision under general anaesthesia. To evaluate the efficacy of ultrasound guided transversus abdominis plane block for postoperative analgesia. Patients were randomly allocated to three groups: control group (n=15), transversus abdominis plane block group (n=15), who received bilateral transversus abdominis plane blockwith 0.25% bupivacaine, and local infiltration group (n=15), who received local wound infiltration with 0.25% bupivacaine at the end of surgery. All patients received intramuscular diclofenac 12 hourly and intravenous tramadol SOS in the postoperative period. Visual analogue scores for pain were assessed at 1,2,4,8,12 and 24 hours postoperatively and these were compared between the three groups. Average tramadol consumption in 24 hours were also compared among the three groups. Data were subjected to univariate ANOVA test and chi-square test. Level of significance was set at 0.05. Visual analogue scores were significantly less in transversus abdominis plane block group and effect lasted up to 12 hours at rest postoperatively and 8 hours during cough and movement. Bilateral Transversus abdominis plane block was effective in reducing postoperative pain scores for 8 to 12 hours postoperatively. This block was also successful in reducing postoperative opioid requirement.

  15. Quadratus Lumborum Block Versus Transversus Abdominis Plane Block for Postoperative Pain After Cesarean Delivery: A Randomized Controlled Trial.

    PubMed

    Blanco, Rafael; Ansari, Tarek; Riad, Waleed; Shetty, Nanda

    Effective postoperative analgesia after cesarean delivery enhances early recovery, ambulation, and breastfeeding. In a previous study, we established the effectiveness of the quadratus lumborum block in providing pain relief after cesarean delivery compared with patient-controlled analgesia (morphine). In the current study, we hypothesized that this method would be equal to or better than the transversus abdominis plane block with regard to pain relief and its duration of action after cesarean delivery. Between April 2015 and August 2015, we randomized 76 patients scheduled for elective cesarean delivery under spinal anesthesia to receive the quadratus lumborum block or the transversus abdominis plane block for postoperative pain relief. This trial was registered prospectively (NCT 02489851) [corrected]. Patients in the quadratus lumborum block group used significantly less morphine than the transversus abdominis plane block group (P < 0.05) at 12, 24, and 48 hours but not at 4 and 6 hours after cesarean delivery. This group also had significantly fewer morphine demands than the control group (P < 0.05) at 6, 12, 24, and 48 hours after cesarean delivery. No significant differences in visual analog scale results were shown between the 2 groups at rest or with movement. Calculated total pain relief at rest and with movement were similar (P < 0.001) in both groups. The quadratus lumborum block was more effective in reducing morphine consumption and demands than transversus abdominis plane blocks after cesarean section. This effect was observed up to 48 hours postoperatively.

  16. Pharmacokinetics of bupivacaine after bilateral ultrasound-guided transversus abdominis plane block following cesarean delivery under spinal anesthesia.

    PubMed

    Trabelsi, B; Charfi, R; Bennasr, L; Marzouk, S Ben; Eljebari, H; Jebabli, N; Sassi, M Ben; Trabelsi, S; Maghrebi, H

    2017-11-01

    Transversus abdominis plane block is an effective method of post-cesarean analgesia. There are no data available about plasma bupivacaine levels after this block in adults. This study aimed to assess bupivacaine pharmacokinetic parameters after ultrasound-guided transversus abdominis plane blocks following cesarean delivery under spinal anesthesia. A prospective observational study in parturients undergoing elective cesarean delivery under hyperbaric bupivacaine spinal anesthesia was conducted. After surgery, patients received bilateral transversus abdominis plane block (50mg bupivacaine each side). Venous blood samples were collected immediately before performing the block and at 10, 20, 30, 45, 60, 90, 120, 180, 240, 720 and 1440minutes. High performance liquid chromatography was used to measure total plasma bupivacaine concentrations. Mean bupivacaine area under the curve (AUC) was calculated from 0 to 24hours. Data were collected from 17 parturients. Mean age and body mass index were 31±6y and 30±4kg/m 2 respectively. Mean plasma bupivacaine concentration before the block was 171ng/mL. Mean peak concentration was 802.36ng/mL (range 231.8 to 3504.5ng/mL). Mean time to peak concentration was 30min and mean area-under-the-curve (0-24h) was 4505.4h.ng/mL. Mean elimination half-life was 8.75h. Three subjects had concentrations above the quoted toxic threshold and mild symptoms suggestive of neurotoxicity were reported by two subjects, but no treatment was required. Single-dose bilateral transversus abdominis plane block using 100mg of bupivacaine, after spinal anesthesia for cesarean delivery, can result in toxic plasma bupivacaine concentrations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Analgesic effect of ultrasound-guided transversus abdominis plane block after total abdominal hysterectomy: a randomized, double-blind, placebo-controlled trial.

    PubMed

    Røjskjaer, Jesper O; Gade, Erik; Kiel, Louise B; Lind, Morten N; Pedersen, Lars M; Kristensen, Billy B; Rasmussen, Yvonne H; Foss, Nicolai B

    2015-03-01

    To assess the effect of bilateral ultrasound-guided transversus abdominis plane block with ropivacaine compared with placebo as part of a multimodal analgesic regimen. A randomized, double-blind, placebo-controlled trial following the CONSORT criteria. Hvidovre University Hospital. Forty-six women scheduled for total abdominal hysterectomy. Women received either ropivacaine 0.75%, 20 mL (n = 24) or 0.9% saline, 20 mL (n = 24) in the transversus abdominis plane on each side. Primary outcome was the 24-h postoperative morphine consumption. Secondary outcomes were pain scores at rest and during coughing, postoperative nausea and vomiting at 1, 2, 4, 6, 8, and 24 h, and time to first mobilization. There was no difference in the mean 24-h postoperative morphine consumption between the two groups (p = 0.733). The ropivacaine group had significantly lower median pain scores at 1 h (p = 0.008) and 2 h (p = 0.027) postoperatively at rest and at 8 h (p = 0.028) during coughing. There was no significant difference in other secondary outcomes. There was no reduction in 24-h morphine consumption when using an ultrasound-guided transversus abdominis plane block in women undergoing total abdominal hysterectomy. As part of a multimodal regimen the transversus abdominis plane block showed some effect on pain scores at rest only in the early postoperative period. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.

  18. Postoperative analgesic efficacy of ultrasound-guided ilioinguinal-iliohypogastric nerve block compared with medial transverse abdominis plane block in inguinal hernia repair: A prospective, randomised trial.

    PubMed

    Bhatia, Nidhi; Sen, Indu Mohini; Mandal, Banashree; Batra, Ankita

    2018-03-29

    Analgesic efficacy of ultrasound-guided transverse abdominis plane block, administered a little more medially, just close to the origin of the transverse abdominis muscle has not yet been investigated in patients undergoing unilateral inguinal hernia repair. We hypothesised that medial transverse abdominis plane block would provide comparable postoperative analgesia to ilioinguinal-iliohypogastric nerve block in inguinal hernia repair patients. This prospective, randomised trial was conducted in 50 ASA I and II male patients≥18 years of age. Patients were randomised into two groups to receive either pre-incisional ipsilateral ultrasound-guided ilioinguinal-iliohypogastric nerve block or medial transverse abdominis plane block, with 0.3ml/kg of 0.25% bupivacaine. Our primary objective was postoperative 24-hour analgesic consumption and secondary outcomes included pain scores, time to first request for rescue analgesic and side effects, if any, in the postoperative period. There was no significant difference in the total postoperative analgesic consumption [group I: 66.04mg; group II: 68.33mg (P value 0.908)]. Time to first request for rescue analgesic was delayed, though statistically non-significant (P value 0.326), following medial transverse abdominis plane block, with excellent pain relief seen in 58.3% patients as opposed to 45.8% patients in ilioinguinal-iliohypogastric nerve block group. Medial transverse abdominis plane block being a novel, simple and easily performed procedure can serve as an useful alternative to ilioinguinal-iliohypogastric nerve block for providing postoperative pain relief in inguinal hernia repair patients. Copyright © 2018 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  19. Ultrasound-Guided Out-of-Plane vs. In-Plane Interscalene Catheters: A Randomized, Prospective Study.

    PubMed

    Schwenk, Eric S; Gandhi, Kishor; Baratta, Jaime L; Torjman, Marc; Epstein, Richard H; Chung, Jaeyoon; Vaghari, Benjamin A; Beausang, David; Bojaxhi, Elird; Grady, Bernadette

    2015-12-01

    Continuous interscalene blocks provide excellent analgesia after shoulder surgery. Although the safety of the ultrasound-guided in-plane approach has been touted, technical and patient factors can limit this approach. We developed a caudad-to-cephalad out-of-plane approach and hypothesized that it would decrease pain ratings due to better catheter alignment with the brachial plexus compared to the in-plane technique in a randomized, controlled study. To compare an out-of-plane interscalene catheter technique to the in-plane technique in a randomized clinical trial. Eighty-four patients undergoing open shoulder surgery were randomized to either the in-plane or out-of-plane ultrasound-guided continuous interscalene technique. The primary outcome was VAS pain rating at 24 hours. Secondary outcomes included pain ratings in the recovery room and at 48 hours, morphine consumption, the incidence of catheter dislodgments, procedure time, and block difficulty. Procedural data and all pain ratings were collected by blinded observers. There were no differences in the primary outcome of median VAS pain rating at 24 hours between the out-of-plane and in-plane groups (1.50; IQR, [0 - 4.38] vs. 1.25; IQR, [0 - 3.75]; P = 0.57). There were also no differences, respectively, between out-of-plane and in-plane median PACU pain ratings (1.0; IQR, [0 - 3.5] vs. 0.25; IQR, [0 - 2.5]; P = 0.08) and median 48-hour pain ratings (1.25; IQR, [1.25 - 2.63] vs. 0.50; IQR, [0 - 1.88]; P = 0.30). There were no differences in any other secondary endpoint. Our out-of-plane technique did not provide superior analgesia to the in-plane technique. It did not increase the number of complications. Our technique is an acceptable alternative in situations where the in-plane technique is difficult to perform.

  20. Comparison of Epidural Analgesia with Transversus Abdominis Plane Analgesia for Postoperative Pain Relief in Patients Undergoing Lower Abdominal Surgery: A Prospective Randomized Study.

    PubMed

    Iyer, Sadasivan Shankar; Bavishi, Harshit; Mohan, Chadalavada Venkataram; Kaur, Navdeep

    2017-01-01

    Anesthesiologists play an important role in postoperative pain management. For analgesia after lower abdominal surgery, epidural analgesia and ultrasound-guided transversus abdominis plane (TAP) block are suitable options. The study aims to compare the analgesic efficacy of both techniques. Seventy-two patients undergoing lower abdominal surgery under spinal anesthesia were randomized to postoperatively receive lumbar epidural catheter (Group E) or ultrasound-guided TAP block (Group T) through intravenous cannulas placed bilaterally. Group E received 10 ml 0.125% bupivacaine stat and 10 ml 8 th hourly for 48 h. Group T received 20 ml 0.125% bupivacaine bilaterally stat and 20 ml bilaterally 8 th hourly for 48 h. Pain at rest and on coughing, total paracetamol and tramadol consumption were recorded. Analgesia at rest was comparable between the groups in the first 16 h. At 24 and 48 h, Group E had significantly better analgesia at rest ( P = 0.001 and 0.004 respectively). Patients in Group E had significantly higher number of patients with nil or mild pain on coughing at all times. Paracetamol consumption was comparable in both groups, but tramadol consumption was significantly higher in Group T at the end of 48 h ( P = 0.001). For lower abdominal surgeries, analgesia provided by intermittent boluses of 0.125% is comparable for first 16 h between epidural and TAP catheters. However, the quality of analgesia provided by the epidural catheter is superior to that provided by TAP catheters beyond that both at rest and on coughing with reduced opioid consumption.

  1. Comparison of Epidural Analgesia with Transversus Abdominis Plane Analgesia for Postoperative Pain Relief in Patients Undergoing Lower Abdominal Surgery: A Prospective Randomized Study

    PubMed Central

    Iyer, Sadasivan Shankar; Bavishi, Harshit; Mohan, Chadalavada Venkataram; Kaur, Navdeep

    2017-01-01

    Background: Anesthesiologists play an important role in postoperative pain management. For analgesia after lower abdominal surgery, epidural analgesia and ultrasound-guided transversus abdominis plane (TAP) block are suitable options. The study aims to compare the analgesic efficacy of both techniques. Materials and Methods: Seventy-two patients undergoing lower abdominal surgery under spinal anesthesia were randomized to postoperatively receive lumbar epidural catheter (Group E) or ultrasound-guided TAP block (Group T) through intravenous cannulas placed bilaterally. Group E received 10 ml 0.125% bupivacaine stat and 10 ml 8th hourly for 48 h. Group T received 20 ml 0.125% bupivacaine bilaterally stat and 20 ml bilaterally 8th hourly for 48 h. Pain at rest and on coughing, total paracetamol and tramadol consumption were recorded. Results: Analgesia at rest was comparable between the groups in the first 16 h. At 24 and 48 h, Group E had significantly better analgesia at rest (P = 0.001 and 0.004 respectively). Patients in Group E had significantly higher number of patients with nil or mild pain on coughing at all times. Paracetamol consumption was comparable in both groups, but tramadol consumption was significantly higher in Group T at the end of 48 h (P = 0.001). Conclusion: For lower abdominal surgeries, analgesia provided by intermittent boluses of 0.125% is comparable for first 16 h between epidural and TAP catheters. However, the quality of analgesia provided by the epidural catheter is superior to that provided by TAP catheters beyond that both at rest and on coughing with reduced opioid consumption. PMID:28928569

  2. Ultrasound guided transversus abdominis plane vs surgeon administered intraoperative regional field infiltration with bupivacaine for early postoperative pain control in children undergoing open pyeloplasty.

    PubMed

    Lorenzo, Armando J; Lynch, Johanne; Matava, Clyde; El-Beheiry, Hossam; Hayes, Jason

    2014-07-01

    Regional analgesic techniques are commonly used in pediatric urology. Ultrasound guided transversus abdominis plane block has recently gained popularity. However, there is a paucity of information supporting a benefit over regional field infiltration. We present a parallel group, randomized, controlled trial evaluating ultrasound guided transversus abdominis plane block superiority over surgeon delivered regional field infiltration for children undergoing open pyeloplasty at a tertiary referral center. Following ethics board approval and registration, children 0 to 6 years old were recruited and randomized to undergo perioperative transversus abdominis plane block or regional field infiltration for early post-pyeloplasty pain control. General anesthetic delivery, surgical technique and postoperative analgesics were standardized. A blinded assessor regularly captured pain scores in the recovery room using the FLACC (Face, Legs, Activity, Cry, Consolability) scale. The primary outcome was the need for rescue morphine administration based on a FLACC score of 3 or higher. Two pediatric urologists performed 57 pyeloplasties during a 2.5-year period, enrolling 32 children (16 in each group, balanced for age and weight). There were statistically significant differences in the number of children requiring rescue morphine administration (13 of 16 receiving transversus abdominis plane block and 6 of 16 receiving regional field infiltration, p = 0.011), mean ± SD total morphine consumption (0.066 ± 0.051 vs 0.028 ± 0.040 mg/kg, p = 0.021) and mean ± SD pain scores (5 ± 5 vs 2 ± 3, p = 0.043) in the recovery room, in favor of surgeon administered regional field infiltration. No local anesthetic specific adverse events were noted. Ultrasound guided transversus abdominis plane block is not superior to regional field infiltration with bupivacaine as a strategy to minimize early opioid requirements following open pyeloplasty in children. Instead, our data suggest that

  3. Transversus abdominis plane block in renal allotransplant recipients: A retrospective chart review.

    PubMed

    Gopwani, S R; Rosenblatt, M A

    2016-01-01

    The efficacy of the transversus abdominis plane (TAP) block appears to vary considerably, depending on the surgical procedure and block technique. This study aims to add to the existing literature and provide a more clear understanding of the TAP blocks role as a postoperative analgesic technique, specifically in renal allotransplant recipients. A retrospective chart review was conducted by querying the intraoperative electronic medical record system of a 1200-bed tertiary academic hospital over a 5 months period, and reviewing anesthetic techniques, as well as postoperative morphine equivalent consumption. Fifty renal allotransplant recipients were identified, 13 of whom received TAP blocks while 37 received no regional analgesic technique. All blocks were performed under ultrasound guidance, with 20 mL of 0.25% bupivacaine injected in the transversus abdominis fascial plane under direct visualization. The primary outcome was postoperative morphine equivalent consumption. Morphine consumption was compared with the two-tailed Mann-Whitney U -test. Continuous variables of patient baseline characteristics were analyzed with unpaired t -test and categorical variables with Fischer Exact Test. A P < 0.05 was considered statistically significant. A statistically significant decrease in cumulative morphine consumption was found in the group that received the TAP block at 6 h (2.46 mg vs. 7.27 mg, P = 0.0010), 12 h (3.88 mg vs. 10.20 mg, P = 0.0005), 24 h (6.96 mg vs. 14.75 mg, P = 0.0013), and 48 h (11 mg vs. 20.13 mg, P = 0.0092). The TAP block is a beneficial postoperative analgesic, opiate-sparing technique in renal allotransplant recipients.

  4. Liposomal Bupivacaine Use in Transversus Abdominis Plane Blocks Reduces Pain and Postoperative Intravenous Opioid Requirement After Colorectal Surgery.

    PubMed

    Stokes, Audrey L; Adhikary, Sanjib D; Quintili, Ashley; Puleo, Frances J; Choi, Christine S; Hollenbeak, Christopher S; Messaris, Evangelos

    2017-02-01

    Enhanced recovery protocols frequently use multimodal postoperative analgesia to improve postoperative outcomes in patients undergoing colorectal surgery. The purpose of this study was to evaluate liposomal bupivacaine use in transversus abdominis plane blocks on postoperative pain scores and opioid use after colorectal surgery. This was a retrospective cohort study comparing outcomes between patients receiving nonliposomal anesthetic (n = 104) and liposomal bupivacaine (n = 303) blocks. The study was conducted at a single tertiary care center. Patients included those identified within an institutional database as inpatients undergoing colorectal procedures between 2013 and 2015 who underwent transversus abdominis plane block for perioperative analgesia. The study measured postoperative pain scores and opioid requirements. Patients receiving liposomal bupivacaine had significantly lower pain scores for the first 24 to 36 postoperative hours. Pain scores were similar after 36 hours. The use of intravenous opioids among the liposomal bupivacaine group decreased by more than one third during the hospitalization (99.1 vs 64.5 mg; p = 0.040). The use of ketorolac was also decreased (49.0 vs 18.3 mg; p < 0.001). In subgroup analysis, the decrease in opioid use was observed between laparoscopic and robotic procedures but not with laparotomies. No significant differences were noted in the use of oral opioids, acetaminophen, or ibuprofen. Postoperative length of stay and total cost were decreased in the liposomal bupivacaine group but did not achieve statistical significance. The study was limited by its retrospective, single-center design and heterogeneity of block administration. Attenuated pain scores observed with liposomal bupivacaine use were associated with significantly lower intravenous opioid and ketorolac use, suggesting that liposomal bupivacaine-containing transversus abdominis plane blocks are well aligned with the opioid-reducing goals of many enhanced

  5. [Case of Leriche's syndrome treated with safe and effective analgesia after laparotomy by transversus abdominis plane block, rectus sheath block, and continuous wound infusion with ropivacaine].

    PubMed

    Hotta, Arisa; Yagi, Yuuki; Hakata, Saaya; Tsumura, Yae; Shimizu, Motoko; Kukida, Ayako; Nakamoto, Ai; Yoshikawa, Noriko; Oohira, Naoko; Tatekawa, Shigeki

    2013-12-01

    Ultrasound-guided peripheral nerve blocks in the abdominal wall, such as transversus abdominis plane block (TAP block) and rectus sheath block, are now widely used. We report a case of Leriche's syndrome treated with safe and effective analgesia after laparotomy by abdominal wall block and continuous infusion. A 61-year-old man diagnosed with Leriche's syndrome underwent Y-graft replacement for an abdominal aortic aneurysm. Preoperative enhanced and 3-dimensional CTs showed many collateral arterial systems, especially in the right abdominal wall. It was suggested that the right internal iliac artery had been completely occluded, and the left one showed severe stenosis. After the induction of general anesthesia, we recognized collateral arteries through an ultrasound view as on preoperative CTs. We lowered the pulse repetition frequency more than usual in order not to injure them. We injected 0.1875% ropivacaine 60 ml as TAP block, and 20 ml as rectus sheath block. When the wound was closed, a catheter was passed through an 18-gauge Tuohy needle placed above the fascia along the supraumbilical site. After the operation, 0.2% ropivacaine was continuously delivered at a rate of 6 ml hr-1 through the catheter. We could provide the patient with effective analgesia after surgery.

  6. Transperitoneal rectus sheath block and transversus abdominis plane block for laparoscopic inguinal hernia repair: A novel approach.

    PubMed

    Nagata, Jun; Watanabe, Jun; Nagata, Masato; Sawatsubashi, Yusuke; Akiyama, Masaki; Tajima, Takehide; Arase, Koichi; Minagawa, Noritaka; Torigoe, Takayuki; Nakayama, Yoshifumi; Horishita, Reiko; Kida, Kentaro; Hamada, Kotaro; Hirata, Keiji

    2017-08-01

    A laparoscopic approach for inguinal hernia repair is now considered the gold standard. Laparoscopic surgery is associated with a significant reduction in postoperative pain. Epidural analgesia cannot be used in patients with perioperative anticoagulant therapy because of complications such as epidural hematoma. As such, regional anesthetic techniques, such as ultrasound-guided rectus sheath block and transversus abdominis plane block, have become increasingly popular. However, even these anesthetic techniques have potential complications, such as rectus sheath hematoma, if vessels are damaged. We report the use of a transperitoneal laparoscopic approach for rectus sheath block and transversus abdominis plane block as a novel anesthetic procedure. An 81-year-old woman with direct inguinal hernia underwent laparoscopic transabdominal preperitoneal inguinal repair. Epidural anesthesia was not performed because anticoagulant therapy was administered. A Peti-needle™ was delivered through the port, and levobupivacaine was injected though the peritoneum. Surgery was performed successfully, and the anesthetic technique did not affect completion of the operative procedure. The patient was discharged without any complications. This technique was feasible, and the procedure was performed safely. Our novel analgesia technique has potential use as a standard postoperative regimen in various laparoscopic surgeries. Additional prospective studies to compare it with other techniques are required. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  7. Evolution of transversus abdominis plane infiltration techniques for postsurgical analgesia following abdominal surgeries.

    PubMed

    Gadsden, Jeffrey; Ayad, Sabry; Gonzales, Jeffrey J; Mehta, Jaideep; Boublik, Jan; Hutchins, Jacob

    2015-01-01

    Transversus abdominis plane (TAP) infiltration is a regional anesthesia technique that has been demonstrated to be effective for management of postsurgical pain after abdominal surgery. There are several different clinical variations in the approaches used for achieving analgesia via TAP infiltration, and methods for identification of the TAP have evolved considerably since the landmark-guided technique was first described in 2001. There are many factors that impact the analgesic outcomes following TAP infiltration, and the various nuances of this technique have led to debate regarding procedural classification of TAP infiltration. Based on our current understanding of fascial and neuronal anatomy of the anterior abdominal wall, as well as available evidence from studies assessing local anesthetic spread and cutaneous sensory block following TAP infiltration, it is clear that TAP infiltration techniques are appropriately classified as field blocks. While the objective of peripheral nerve block and TAP infiltration are similar in that both approaches block sensory response in order to achieve analgesia, the technical components of the two procedures are different. Unlike peripheral nerve block, which involves identification or stimulation of a specific nerve or nerve plexus, followed by administration of a local anesthetic in close proximity, TAP infiltration involves administration and spread of local anesthetic within an anatomical plane of the surgical site.

  8. Transversus abdominis plane (TAP) block in laparoscopic colorectal surgery improves postoperative pain management: a meta-analysis.

    PubMed

    Hain, E; Maggiori, L; Prost À la Denise, J; Panis, Y

    2018-04-01

    Transversus abdominis plane (TAP) block is a locoregional anaesthesia technique of growing interest in abdominal surgery. However, its efficacy following laparoscopic colorectal surgery is still debated. This meta-analysis aimed to assess the efficacy of TAP block after laparoscopic colorectal surgery. All comparative studies focusing on TAP block after laparoscopic colorectal surgery have been systematically identified through the MEDLINE database, reviewed and included. Meta-analysis was performed according to the Mantel-Haenszel method for random effects. End-points included postoperative opioid consumption, morbidity, time to first bowel movement and length of hospital stay. A total of 13 studies, including 7 randomized controlled trials, were included, comprising a total of 600 patients who underwent laparoscopic colorectal surgery with TAP block, compared with 762 patients without TAP block. Meta-analysis of these studies showed that TAP block was associated with a significantly reduced postoperative opioid consumption on the first day after surgery [weighted mean difference (WMD) -14.54 (-25.14; -3.94); P = 0.007] and a significantly shorter time to first bowel movement [WMD -0.53 (-0.61; -0.44); P < 0.001] but failed to show any impact on length of hospital stay [WMD -0.32 (-0.83; 0.20); P = 0.23] although no study considered length of stay as its primary outcome. Finally, TAP block was not associated with a significant increase in the postoperative overall complication rate [OR = 0.84 (0.62-1.14); P = 0.27]. Transversus abdominis plane (TAP) block in laparoscopic colorectal surgery improves postoperative opioid consumption and recovery of postoperative digestive function without any significant drawback. Colorectal Disease © 2018 The Association of Coloproctology of Great Britain and Ireland.

  9. Postoperative analgesic efficacy of single-shot and continuous transversus abdominis plane block after laparoscopic cholecystectomy: A randomized controlled clinical trial.

    PubMed

    Choi, Yun-Mi; Byeon, Gyeong-Jo; Park, Soon-Ji; Ok, Young-Min; Shin, Sang-Wook; Yang, Kwangho

    2017-06-01

    To compare the analgesic efficacy of ultrasound-guided single-shot and continuous transversus abdominis plane (TAP) block to that of IV-PCA in patients undergoing laparoscopic cholecystectomy. Prospective randomized controlled trial. Post-anesthesia care unit and General ward. 108 American Society of Anesthesiologist (ASA) physical status I-II patients undergoing laparoscopic cholecystectomy. Group A received IV-PCA; group B received both ultrasound-guided single-shot TAP block with 0.2% ropivacaine (20mL) and IV-PCA; and group C received continuous TAP block using an ultrasound-guidance-inserted indwelling catheter. In group C, infusion of 0.2% ropivacaine at a basal rate of 3mL/h, bolus dose of 4mL, and a lockout interval of 30min was maintained for 48h postoperatively. The primary outcome was evaluated analgesic efficacy using the numeric rating scale (NRS) for 48h postoperatively. Other outcomes included the number of patients requiring additional analgesics, patient satisfaction with postoperative pain control, and incidence of postoperative adverse events. Compared to other groups, group C had higher deep abdominal NRS at 1h postoperatively (P<0.05), and lower incidence of postoperative urinary retention (P<0.05). There were no significant intergroup differences in the number of patients requiring additional analgesics, and patient satisfaction with postoperative pain control. Compared to IV-PCA with or without single-shot TAP block, ultrasound-guided continuous TAP block provided similar analgesia in somatic pain and less analgesia in visceral pain. Moreover, the latter resulted in a lower incidence of postoperative urinary retention. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Analgesic efficacy of transversus abdominis plane block in neonates and early infants for colostomy and reversal of colostomy.

    PubMed

    Chen, Chee Kean; Teo, Shu Ching; Phui, Vui Eng; Saman, Mat Ariffin

    2015-01-01

    The application of ultrasound-guided transversus abdominis plane (TAP) block in paediatric population is gaining popularity among anaesthetists. We present a case series of ultrasound-guided TAP block in ten neonate and infants undergoing colostomy and reversal of stoma. Classical TAP as described by Hebbard was carried out and a maximum dosage of 1ml/kg of 0.25% levobupivacaine was injected. Pain score was assessed using Neonatal Infant Pain Scale for 24 hours. In all patients, the block was successful with minimal hemodynamic changes intraoperatively and no additional systemic analgesia was needed intraoperative and immediate postoperatively. Ultrasound-guided TAP block has an important role in providing safe and effective analgesia for colostomy creation and reversal of stoma surgeries in paediatric population.

  11. Randomized clinical trial of transversus abdominis plane block versus placebo control in live-donor nephrectomy.

    PubMed

    Hosgood, Sarah A; Thiyagarajan, Umasanker M; Nicholson, Harriet F L; Jeyapalan, Inthira; Nicholson, Michael L

    2012-09-15

    Laparoscopic surgery reduces pain after donor nephrectomy; however, most patients still require a significant amount of postoperative parenteral opiate analgesia. Therefore, there is a need to investigate techniques that might further reduce postoperative pain. This study assessed the safety and efficacy of using a transversus abdominis plane (TAP) block in a randomized, double-blind, placebo-controlled trial. Forty-six patients were analyzed in the trial and were randomized to undergo the TAP block procedure with either bupivacaine (n=24) or saline placebo (Control n=22) injected into the muscle plane. Prefilled syringes were dispensed with the group allocation concealed to maintain blinding. After surgery, the amount of morphine, level of pain, and measures of recovery were recorded. The amount of morphine used 6 hr after surgery was significantly lower in patients receiving TAP block with bupivacaine compared with the control (presented as mean [SD], 12.4 [8.4] vs. 21.2 [14.0] mg; P=0.015). However, the total amount of morphine used was similar in both groups 45.6 [31.4] vs. 52.7 [28.8] mg; P=0.771. Patients in the bupivacaine group experienced significantly less pain on postoperative days 1 (score, 19 [15] vs. 37 [20]; P=0.003) and 2 (score, 11 [10] vs. 19 [13]; P=0.031). Recovery and postoperative hospital stay were similar in both groups. There were no complications associated with the procedure. The TAP block procedure is beneficial in reducing postoperative pain and early morphine requirements in laparoscopic live-donor nephrectomy.

  12. Comparison of ultrasound-guided posterior transversus abdominis plane block and lateral transversus abdominis plane block for postoperative pain management in patients undergoing cesarean section: a randomized double-blind clinical trial study.

    PubMed

    Faiz, Seyed Hamid Reza; Alebouyeh, Mahmoud Reza; Derakhshan, Pooya; Imani, Farnad; Rahimzadeh, Poupak; Ghaderi Ashtiani, Maryam

    2018-01-01

    Due to the importance of pain control after abdominal surgery, several methods such as transversus abdominis plane (TAP) block are used to reduce the pain after surgery. TAP blocks can be performed using various ultrasound-guided approaches. Two important approaches to do this are ultrasound-guided lateral and posterior approaches. This study aimed to compare the two approaches of ultrasound-guided lateral and posterior TAP blocks to control pain after cesarean section. In this double-blind clinical trial study, 76 patients scheduled for elective cesarean section were selected and randomly divided into two groups of 38 and underwent spinal anesthesia. For pain management after the surgery, one group underwent lateral TAP block and the other group underwent posterior TAP block using 20cc of ropivacaine 0.2% on both sides. Pain intensity was evaluated based on Numerical Analog Scale (NAS) at rest and when coughing, 2, 4, 6, 12, 24 and 36 hours after surgery. The pain at rest in the posterior group at all hours post surgery was lower than the lateral group, especially at 6, 12 and 24 hours after the surgery and the difference was statistically significant ( p =0.03, p <0.004, p =0.001). The results of this study show that ultrasound-guided posterior TAP block compared with the lateral TAP block was more effective in pain control after cesarean section.

  13. Effect of transversus abdominis plane block on cost of laparoscopic cholecystectomy anesthesia.

    PubMed

    Kokulu, Serdar; Bakı, Elif Doğan; Kaçar, Emre; Bal, Ahmet; Şenay, Hasan; Üstün, Kübra Demir; Yılmaz, Sezgin; Ela, Yüksel; Sıvacı, Remziye Gül

    2014-12-23

    Use of transversus abdominis plane (TAP) block for postoperative analgesia is continuously increasing. However, few studies have investigated intraoperative effects of TAP block. We aimed to study the effects of TAP block in terms of cost-effectiveness and consumption of inhalation agents. Forty patients undergoing laparoscopic cholecystectomy were enrolled in this study. Patients were randomly divided into 2 groups: Group 1 (n=20) patients received TAP block and Group 2 (n=20) patients did not receive TAP block. Standard anesthesia induction was used in all patients. For the maintenance of anesthesia, fractional inspired oxygen (FIO2) of 50% in air with desflurane was used with a fresh gas flow of 4 L/min. All patients were monitored with electrocardiography and for peripheral oxygen saturation (SpO2), end-tidal carbon dioxide (ET), heart rate (HR), noninvasive mean blood pressure (MBP), and bispectral index (BIS). Bilateral TAP blocks were performed under ultrasound guidance to Group 1 patients. The BIS value was maintained at between 40 and 50 during the surgery. The Dion formula was used to calculate consumption of desflurane for each patient. There was no difference between the groups with respect to demographic characteristics of the patients. Duration of anesthesia, surgery time, and dosage of fentanyl were similar in the 2 groups. However, the cost and consumption of desflurane was significantly lower in Group 1. Total anesthesia consumption was lower and the cost-effectiveness of anesthesia was better in TAP block patients with general anesthesia than in non-TAP block patients undergoing laparoscopic cholecystectomy.

  14. Effect of Transversus Abdominis Plane Block on Cost of Laparoscopic Cholecystectomy Anesthesia

    PubMed Central

    Kokulu, Serdar; Bakı, Elif Doğan; Kaçar, Emre; Bal, Ahmet; Şenay, Hasan; Üstün, Kübra Demir; Yılmaz, Sezgin; Ela, Yüksel; Sıvacı, Remziye Gül

    2014-01-01

    Background Use of transversus abdominis plane (TAP) block for postoperative analgesia is continuously increasing. However, few studies have investigated intraoperative effects of TAP block. We aimed to study the effects of TAP block in terms of cost-effectiveness and consumption of inhalation agents. Material/Methods Forty patients undergoing laparoscopic cholecystectomy were enrolled in this study. Patients were randomly divided into 2 groups: Group 1 (n=20) patients received TAP block and Group 2 (n=20) patients did not receive TAP block. Standard anesthesia induction was used in all patients. For the maintenance of anesthesia, fractional inspired oxygen (FIO2) of 50% in air with desflurane was used with a fresh gas flow of 4 L/min. All patients were monitored with electrocardiography and for peripheral oxygen saturation (SpO2), end-tidal carbon dioxide (ET), heart rate (HR), noninvasive mean blood pressure (MBP), and bispectral index (BIS). Bilateral TAP blocks were performed under ultrasound guidance to Group 1 patients. The BIS value was maintained at between 40 and 50 during the surgery. The Dion formula was used to calculate consumption of desflurane for each patient. Results There was no difference between the groups with respect to demographic characteristics of the patients. Duration of anesthesia, surgery time, and dosage of fentanyl were similar in the 2 groups. However, the cost and consumption of desflurane was significantly lower in Group 1. Conclusions Total anesthesia consumption was lower and the cost-effectiveness of anesthesia was better in TAP block patients with general anesthesia than in non-TAP block patients undergoing laparoscopic cholecystectomy. PMID:25534331

  15. Case Report of Serratus Plane Catheter for Pain Management in a Patient With Multiple Rib Fractures and an Inferior Scapular Fracture.

    PubMed

    Fu, Peter; Weyker, Paul D; Webb, Christopher A J

    2017-03-15

    We placed a superficial serratus anterior plane catheter in an elderly woman with dementia and elevated clotting times who presented with multiple rib fractures after a mechanical fall. She was not a surgical candidate, and treatment consisted of conservative management with physical therapy and pain control. She was not a candidate for a patient-controlled analgesia regimen because of her dementia. Given her elevated international normalized ratio, thoracic epidural and paravertebral analgesia was also contraindicated. We placed an ultrasound-guided serratus anterior plane catheter, allowing titratable continuous infusion in a trauma patient, resulting in excellent analgesia without adverse effects.

  16. Continuous Transversus Abdominis Plane Nerve Blocks: Does Varying Local Anesthetic Delivery Method-Automatic Repeated Bolus Versus Continuous Basal Infusion-Influence the Extent of Sensation to Cold?: A Randomized, Triple-Masked, Crossover Study in Volunteers.

    PubMed

    Khatibi, Bahareh; Said, Engy T; Sztain, Jacklynn F; Monahan, Amanda M; Gabriel, Rodney A; Furnish, Timothy J; Tran, Johnathan T; Donohue, Michael C; Ilfeld, Brian M

    2017-04-01

    It remains unknown whether continuous or scheduled intermittent bolus local anesthetic administration is preferable for transversus abdominis plane (TAP) catheters. We therefore tested the hypothesis that when using TAP catheters, providing local anesthetic in repeated bolus doses increases the cephalad-caudad cutaneous effects compared with a basal-only infusion. Bilateral TAP catheters (posterior approach) were inserted in 24 healthy volunteers followed by ropivacaine 2 mg/mL administration for a total of 6 hours. The right side was randomly assigned to either a basal infusion (8 mL/h) or bolus doses (24 mL administered every 3 hours for a total of 2 bolus doses) in a double-masked manner. The left side received the alternate treatment. The primary end point was the extent of sensory deficit as measured by cool roller along the axillary line at hour 6 (6 hours after the local anesthetic administration was initiated). Secondary end points included the extent of sensory deficit as measured by cool roller and Von Frey filaments along the axillary line and along a transverse line at the level of the anterior superior iliac spine at hours 0 to 6. Although there were statistically significant differences between treatments within the earlier part of the administration period, by hour 6 the difference in extent of sensory deficit to cold failed to reach statistical significance along the axillary line (mean = 0.9 cm; SD = 6.8; 95% confidence interval -2.0 to 3.8; P = .515) and transverse line (mean = 2.5 cm; SD = 10.1; 95% confidence interval -1.8 to 6.8; P = .244). Although the difference between treatments was statistically significant at various early time points for the horizontal, vertical, and estimated area measurements of both cold and mechanical pressure sensory deficits, no comparison remained statistically significant by hour 6. No evidence was found in this study involving healthy volunteers to support the hypothesis that changing the local anesthetic

  17. Transversus Abdominis Plane Block Versus Surgical Site Infiltration for Pain Management After Open Total Abdominal Hysterectomy.

    PubMed

    Gasanova, Irina; Alexander, John; Ogunnaike, Babatunde; Hamid, Cherine; Rogers, David; Minhajuddin, Abu; Joshi, Girish P

    2015-11-01

    Surgical site infiltration and transversus abdominis plane (TAP) blocks are commonly used to improve pain relief after lower abdominal surgery. This randomized, observer-blinded study was designed to compare the analgesic efficacy of TAP blocks with surgical site infiltration in patients undergoing open total abdominal hysterectomy via a Pfannenstiel incision. Patients were randomized to receive either bilateral ultrasound-guided TAP blocks using bupivacaine 0.5% 20 mL on each side (n = 30) or surgical site infiltration with liposomal bupivacaine 266 mg diluted to 60 mL injected in the preperitoneal, subfascial, and subcutaneous planes (n = 30). The remaining aspects of the perioperative care were standardized. An investigator blinded to the group allocation documented pain scores at rest and with coughing, opioid requirements, nausea, vomiting, and rescue antiemetics in the postanesthesia care unit and at 2, 6, 12, 24, and 48 hours postoperatively. The primary outcome measure was pain scores on coughing at 6 hours postoperatively. One patient in each group was excluded from the analysis because of reoperation within 24 hours in the TAP block group and change of incision type in the infiltration group. The pain scores at rest and with coughing were significantly lower in the surgical site infiltration group at all postoperative time points (P < 0.0001) except at rest in the postanesthesia care unit. The opioid requirements between 24 and 48 hours were significantly lower in the infiltration group (P = 0.009). The nausea scores, occurrence of vomiting, and need for rescue antiemetics were similar. Surgical site infiltration provided superior pain relief at rest and on coughing, as well as reduced opioid consumption for up to 48 hours. Future studies need to compare TAP blocks with liposomal bupivacaine with surgical site infiltration with liposomal bupivacaine.

  18. Quadratus lumborum catheters for breast reconstruction requiring transverse rectus abdominis myocutaneous flaps.

    PubMed

    Spence, Nicole Z; Olszynski, Patrycja; Lehan, Anne; Horn, Jean-Lois; Webb, Christopher A J

    2016-06-01

    Patients diagnosed with breast cancer may opt to undergo surgical reconstructive flaps at the time of or after mastectomies. These surgeries leave patients with significant postoperative pain and sometimes involve large surgical beds including graft sites from the abdomen to reconstruct the breast. Consequently, multimodal methods of pain management have become highly favored. Quadratus lumborum catheters offer an opioid-sparing technique that can be performed easily and safely. We present a case of a patient who underwent a breast flap reconstruction and had bilateral quadratus lumborum catheters placed for perioperative pain control.

  19. Adding a transversus abdominis plane block to parenteral opioid for postoperative analgesia following trans-abdominal hysterectomy in a low resource setting: a prospective, randomised, double blind, controlled study.

    PubMed

    Moyo, Nomaqhawe; Madzimbamuto, Farai D; Shumbairerwa, Samson

    2016-01-28

    The current gold standard treatment for acute postoperative pain after major abdominal surgery is multimodal analgesia using patient controlled analgesia delivery systems. Patient controlled analgesia systems are expensive and their routine use in very low income countries is not practical. The use of ultrasound in anaesthesia has made some regional anaesthesia blocks technically easy and safe to perform. This study aimed to determine whether adding an ultrasound guided transversus abdominis plane block as an adjunct to the current parenteral opioid based regimen would result in superior pain relief after a trans abdominal hysterectomy compared to using parenteral opioids alone. Thirty-two elective patients having trans abdominal hysterectomy were recruited into a prospective randomised double-blind, controlled study comparing a bilateral transversus abdominis plane block using 21 ml of 0.25% bupivacaine and 4.0 mg dexamethasone with a sham block containing 21 ml 0.9% saline. Sixteen patients were allocated to each group. Anaesthesia and postoperative analgesia was left to the attending anaesthetist's discretion. Primary outcome was visual analogue scale for pain at 2 h and 4 h. Secondary outcomes were time to first request for analgesia, visual analogue scale for comfort and bother. The data were analysed using the Statistical Package for Social Sciences (SPSS version 16). There was no statistically significant difference in the demographics of the two groups regarding weight, height, physical status and type of surgical incision. There was a statistically significant difference in visual analogue scale for pain at 4 h during movement with lower pain scales in the test group (p = 0.034). Women in the control group had an average pain free period of 56.8 min (median 56.5 min) before requesting a rescue analgesic compared to 116.5 min (median 103 min) in the study group. The between group difference in the average total analgesia duration was statistically

  20. The effect of morphine added to bupivacaine in ultrasound guided transversus abdominis plane (TAP) block for postoperative analgesia following lower abdominal cancer surgery, a randomized controlled study.

    PubMed

    El Sherif, Fatma Adel; Mohamed, Sahar Abdel-Baky; Kamal, Shereen Mamdouh

    2017-06-01

    Transversus abdominis plane (TAP) block used for management of surgical abdominal pain by injecting local anesthetics into the plane between the internal oblique and transversus abdominis muscles. We aimed to explore the effect of adding morphine to bupivacaine in ultrasound guided TAP-block in patients undergoing lower abdominal cancer surgery. Randomized, double-blind, prospective study. Clinical trial identifier: NCT02566096. Academic medical center. Sixty patients were enrolled in this study after ethical committee approval. Patients divided into 2 groups (30 each): Bupivacaine group (GB): given ultrasound guided TAP-block 20ml 0.5% bupivacaine diluted in 20ml saline; Morphine group (GM): given ultrasound guided TAP-block with 20ml 0.5% bupivacaine+10mg morphine sulphate diluted in 20ml saline. Patients were observed for total morphine consumption, time for first request of rescue analgesia, sedation scores, hemodynamics and side effects for 24h postoperatively. Morphine added to bupivacaine in TAP block compared to bupivacaine alone reduced total morphine consumption (5.33±1.28mg) (10.70±3.09mg) respectively (p<0.001), prolonged the time to first request of analgesia (10.40±4.96h) (6.97±3.26h) respectively (p<0.008), with a statistically significant decrease in (VAS-M) in GM compared with GB at 12h postoperatively (p<0.002). No significant differences in hemodynamics, respiratory rate, oxygen saturation, sedation score, and side effects except for nausea were observed (p>0.05). Addition of morphine to bupivacaine in TAP block is effective method for pain management in patients undergoing major abdominal cancer surgery without serious side effects. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Rectus sheath catheters for continuous analgesia after upper abdominal surgery.

    PubMed

    Cornish, Philip; Deacon, Alf

    2007-01-01

    The segmental nerves T6-T11 pass through and innervate the rectus abdominis muscle and overlying skin. The arcuate lines compartmentalize the rectus, but they are deficient posteriorly and hence a catheter tunnelled into the posterior sheath can be used to achieve an effective continuous analgesic block. Volume is important to fill the compartment. It is a simple surgical procedure that has several advantages and appears a viable alternative to epidural analgesia.

  2. A randomized trial comparing surgeon-administered intraoperative transversus abdominis plane block with anesthesiologist-administered transcutaneous block.

    PubMed

    Narasimhulu, D M; Scharfman, L; Minkoff, H; George, B; Homel, P; Tyagaraj, K

    2018-04-27

    Injection of local anesthetic into the transversus abdominis plane (TAP block) decreases systemic morphine requirements after abdominal surgery. We compared intraoperative surgeon-administered TAP block (surgical TAP) to anesthesiologist-administered transcutaneous ultrasound-guided TAP block (conventional TAP) for post-cesarean analgesia. We hypothesized that surgical TAP blocks would take less time to perform than conventional TAP blocks. We performed a randomized trial, recruiting 41 women undergoing cesarean delivery under neuraxial anesthesia, assigning them to either surgical TAP block (n=20) or conventional TAP block (n=21). Time taken to perform the block was the primary outcome, while postoperative pain scores and 24-hour opioid requirements were secondary outcomes. Student's t-test was used to compare block time and Kruskal-Wallis test opioid consumption and pain-scores. Time taken to perform the block (2.4 vs 12.1 min, P <0.001), and time spent in the operating room after delivery (55.3 vs 77.9 min, P <0.001) were significantly less for surgical TAP. The 24 h morphine consumption (P=0.17) and postoperative pain scores at 4, 8, 24 and 48 h were not significantly different between the groups. Surgical TAP blocks are feasible and less time consuming than conventional TAP blocks, while providing comparable analgesia after cesarean delivery. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Transversus abdominis plane block as a component of multimodal analgesia for laparoscopic cholecystectomy.

    PubMed

    Oksar, Menekse; Koyuncu, Onur; Turhanoglu, Selim; Temiz, Muhyittin; Oran, Mustafa Cemil

    2016-11-01

    To evaluate and compare intercostal-iliac transversus abdominis plane (TAP) and oblique subcostal TAP (OSTAP) blocks for multimodal analgesia in patients receiving laparoscopic cholecystectomy. A prospective, randomized, double-blinded clinical study. Operating room, postoperative recovery area, and ward. In total, 60 laparoscopic cholecystectomy patients (43 women, 17 men, American Society of Anesthesiologists grades I-II) were enrolled from the general surgery department of our tertiary care center. The patients were assigned to 1 of the 3 groups. Group 1 received TAP blocks (n=20), group 2 received OSTAP blocks (n=20), and group 3 patients were used as controls and received patient-controlled analgesia (PCA) only (n=20). After the induction of anesthesia, blocks were performed bilaterally in study groups 1 and 2, using 20mL of lidocaine (5mg/mL). PCA with intravenous tramadol was routinely provided for all patients during the first 24hours. The intraoperative use of remifentanil, postoperative visual analog scale (VAS) scores, demand for PCA, and total analgesic consumption were recorded. The patients in the control group had greater analgesic demands and analgesic consumption than did those in groups 1 and 2. However, patients in the OSTAP group had lower VAS scores than did those in groups 1 and 3. The demand for analgesia was greater in the control group than in groups 1 and 2. Moreover, lower VAS scores were recorded in the OSTAP group than in groups 1 and 3 and were positively correlated with total PCA consumption among all patients. However, postoperative VAS scores were negatively correlated with the total intraoperative consumption of remifentanil at 24hours. TAP and OSTAP blocks improved postoperative analgesia in patients receiving laparoscopic cholecystectomy, which resulted in lower VAS scores and reduction in total analgesic consumption. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Comparison of efficacy and safety of lateral-to-medial continuous transversus abdominis plane block with thoracic epidural analgesia in patients undergoing abdominal surgery: A randomised, open-label feasibility study.

    PubMed

    Ganapathy, Sugantha; Sondekoppam, Rakesh V; Terlecki, Magdalena; Brookes, Jonathan; Das Adhikary, Sanjib; Subramanian, Lakshmimathy

    2015-11-01

    We recently described a lateral-to-medial approach for transversus abdominis plane (LM-TAP) block, which may permit preoperative initiation of the block. Our objective was to evaluate the feasibility of continuous LM-TAP blocks in clinical practice in comparison with thoracic epidural analgesia (TEA). A randomised, open-label study. University Hospital, London Health Sciences Centre, London, Ontario, Canada from July 2008 to August 2012. Fifty adult patients undergoing open abdominal surgery via laparotomy were allocated randomly to receive preoperative catheter-congruent TEA or ultrasound-guided continuous bilateral LM-TAP block for 72 h postoperatively. Reasons for noninclusion were American Society of Anesthesiologists' physical status more than 4, known allergy to study drugs, chronic pain/opioid dependence, spinal abnormalities or psychiatric illness. In the TEA group (n = 24), patient-controlled epidural analgesia was maintained using bupivacaine 0.1% with hydromorphone 10 μg ml⁻¹ after establishment of the initial block. In the LM-TAP group (n = 26), ultrasound-guided LM-TAP catheters were inserted on each side preoperatively after a bolus of 30 ml of ropivacaine 0.5% (20 ml subcostal and 10 ml subumbilical injections on both sides). Analgesia was maintained with an infusion of ropivacaine 0.35% at a rate of 2 to 2.5 ml h⁻¹ through each catheter, along with rescue intravenous patient-controlled analgesia. The primary outcome was pain score on coughing 24 h after the end of surgery. Secondary outcomes were pain scores from 24 to 72 h, intraoperative and postoperative opioid consumption, time to onset of bowel movement and side effect profiles. Mean [95% confidence interval (95% CI)] pain scores at rest ranged from 1. 7 (0.9 to 2.5) to 2.3 (1.1 to 3.4) in TEA vs. 1.5 (0.7 to 2.2) to 2.2 (1.3 to 3.0) in LM-TAP (P = 0.829). The dynamic pain scores ranged from 2.9 (1.5 to 4.4) to 3.8 (2.8 to 4.8) in TEA vs. 3.3 (2.4 to 4

  5. Efficacy of transversus abdominis plane block with liposomal bupivacaine during open abdominal wall reconstruction.

    PubMed

    Fayezizadeh, Mojtaba; Majumder, Arnab; Neupane, Ruel; Elliott, Heidi L; Novitsky, Yuri W

    2016-09-01

    Transversus abdominis plane block (TAPb) is an analgesic adjunct used for abdominal surgical procedures. Liposomal bupivacaine (LB) demonstrates prolonged analgesic effects, up to 72 hours. We evaluated the analgesic efficacy of TAPb using LB for patients undergoing open abdominal wall reconstruction (AWR). Fifty patients undergoing AWR with TAPb using LB (TAP-group) were compared with a matched historical cohort undergoing AWR without TAPb (control group). Outcome measures included postoperative utilization of morphine equivalents, numerical rating scale pain scores, time to oral narcotics, and length of stay (LOS). Cohorts were matched demographically. No complications were associated with TAPb or LB. TAP-group evidenced significantly reduced narcotic requirements on operative day (9.5 mg vs 16.5 mg, P = .004), postoperative day (POD) 1 (26.7 mg vs 39.5 mg, P = .01) and POD2 (29.6 mg vs 40.7 mg, P = .047) and pain scores on operative day (5.1 vs 7.0, P <.001), POD1 (4.2 vs 5.5, P = .002), and POD2 (3.9 vs 4.8, P = .04). In addition, TAP-group demonstrated significantly shorter time to oral narcotics (2.7 days vs 4.0 days, P <.001) and median LOS (5.2 days vs 6.8 days, P = .004). TAPb with LB demonstrated significant reductions in narcotic consumption and improved pain control. TAPb allowed for earlier discontinuation of intravenous narcotics and shorter LOS. Intraoperative TAPb with LB appears to be an effective adjunct for perioperative analgesia in patients undergoing open AWR. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. No benefit of ultrasound-guided transversus abdominis plane blocks over wound infiltration with local anaesthetic in elective laparoscopic colonic surgery: results of a double-blind randomized controlled trial.

    PubMed

    Rashid, A; Gorissen, K J; Ris, F; Gosselink, M P; Shorthouse, J R; Smith, A D; Pandit, J J; Lindsey, I; Crabtree, N A

    2017-07-01

    Advances in laparoscopic techniques combined with enhanced recovery pathways have led to faster recuperation and discharge after colorectal surgery. Peripheral nerve blockade using transversus abdominis plane (TAP) blocks reduce opioid requirements and provide better analgesia for laparoscopic colectomies than do inactive controls. This double-blind randomized study was performed to compare TAP blocks using bupivacaine with standardized wound infiltration with local anaesthetic (LA). Seventy-one patients were randomized to receive either TAP block or wound infiltration. The TAP blocks were performed by experienced anaesthetists who used ultrasound guidance to deliver 40 ml of 0.25% bupivacaine post-induction into the transverse abdominis plane. In the control group, 40 ml of 0.25% bupivacaine was injected around the trocar and the extraction site by the surgeon. Both groups received patient-controlled analgesia (PCA) with intravenous morphine. Patients and nursing staff assessed pain scores 6, 12, 24 and 48 h after surgery. The primary outcome was overall morphine use in the first 48 h. Of the 71 patients, 20 underwent a right hemicolectomy and 51 a high anterior resection. The modified intention-to-treat analysis showed no significant differences in overall morphine use [47.3 (36.2-58.5) mg vs 46.7 (36.2-57.3) mg; mean (95% CI), P = 0.8663] in the first 48 h. Pain scores were similar at 6, 12, 24 and 48 h. No differences were found regarding time to mobilization, resumption of diet and length of hospital stay. In elective laparoscopic colectomies, standardized wound infiltration with LA has the same analgesic effect as TAP blocks post-induction using bupivacaine at 48 h. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  7. A randomised controlled trial investigating the analgesic efficacy of transversus abdominis plane block for adult laparoscopic appendicectomy.

    PubMed

    Tupper-Carey, Darell Alexander; Fathil, Shahridan Mohd; Tan, Yin Kiat Glenn; Kan, Yuk Man; Cheong, Chern Yuen; Siddiqui, Fahad Javaid; Assam, Pryseley Nkouibert

    2017-08-01

    We conducted a single-centre, prospective randomised clinical trial to investigate the analgesic efficacy of transversus abdominis plane (TAP) block in adult patients undergoing laparoscopic appendicectomy. Patients undergoing urgent laparoscopic appendicectomy under general anaesthesia alone (control group) and general anaesthesia supplemented by TAP block (TAP intervention group) were compared. All patients received a multimodal analgesia regime, which included postoperative morphine via a patient-controlled analgesia device. The primary endpoints were morphine consumption at 12 hours and 24 hours postoperatively. Secondary endpoints included pain scores, incidence of nausea and vomiting, and time to hospital discharge. A total of 58 patients were recruited, with 29 patients in each group. Mean postoperative morphine consumption at 12 hours (control group: 11.45 ± 7.64 mg, TAP intervention group: 9.79 ± 8.09 mg; p = 0.4264) and 24 hours (control group: 13.38 ± 8.72 mg, TAP intervention group: 11.31 ± 8.66 mg; p = 0.3686) for the control and TAP intervention groups were not statistically different. Secondary outcomes were also not different between the two groups. Length of stay in the post-anaesthesia care unit was significantly shorter for the TAP intervention group, with a trend toward faster hospital discharge being observed. TAP block, a regional anaesthetic procedure performed immediately prior to skin incision for laparoscopic appendicectomy, did not significantly improve postoperative analgesia outcomes. Copyright: © Singapore Medical Association

  8. Transversus abdominis plane block vs. wound infiltration in Caesarean section: a randomised controlled trial.

    PubMed

    Telnes, A; Skogvoll, E; Lonnée, H

    2015-04-01

    Multiple studies suggest that transversus abdominis plane (TAP) block (without intrathecal morphine) after Caesarean section (CS) reduces post-operative morphine consumption. In our study, we wanted to compare the analgesic effect of TAP block with infiltration of the wound after CS. We included 60 pregnant women scheduled for elective CS under spinal anaesthesia in a randomised, single-centre, double-blind study. Thirty patients received ultrasound-guided TAP block using 20 ml bupivacaine 0.25% with adrenaline 5 μg/ml bilaterally and 20 ml normal saline as wound infiltration (TAP group). The other 30 patients (the control group) received normal saline 20 ml bilaterally in the TAP, and 20 ml bupivacaine 0.25% with adrenaline 5 μg/ml as wound infiltration. The main outcome was cumulative morphine consumption at 48 h after surgery. In addition, continuous morphine consumption, pain scores and side effects were registered. Fifty-seven patients completed the study. Cumulative morphine consumption at 48 h (mean±standard deviation) was 41±34 mg in the TAP group and 38±27 mg in the control group (P=0.7); a difference of 3 mg (95% confidence interval -13 to 19 mg). Morphine consumption at any time up to 48 h was virtually identical in both groups. Side effects were similar, except for a higher degree of sedation in the TAP group (P=0.04). Compared with wound infiltration with local anaesthetics, TAP block did not reduce cumulative morphine consumption following CS. The TAP block was associated with more pronounced sedation. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Efficacy of transverse abdominis plane block in reduction of postoperation pain in laparoscopic cholecystectomy.

    PubMed

    Saliminia, Alireza; Azimaraghi, Omid; Babayipour, Shiva; Ardavan, Kamelia; Movafegh, Ali

    2015-12-01

    Transversus abdominis plane (TAP) block is a recently introduced regional anesthesia technique that is used for postoperative pain reduction in some abdominal surgeries. The present study evaluated the efficacy of the TAP block on the post laparoscopic cholecystectomy pain intensity and analgesic consumption. Fifty-four patients were enrolled in three groups: TAP block with normal saline (Group 1, n = 18); TAP block with bupivacaine (Group 2, n = 18); and TAP block with bupivacaine plus sufentanil (Group 3, n = 18). The time to the first fentanyl request, fentanyl consumption in the 24 hours following surgery, and postoperative pain intensity at 30 minutes, 1 hour, 6 hours, 12 hours, and 24 hours following discharge for recovery were measured and recorded. The total amount of 24-hour fentanyl consumption was higher in Group 1 (877.8 ± 338.8 μg) than either Group 2 (566.7 ± 367.8 μg) or Group 3 (555.5 ± 356.8 μg; p = 0.03). Postoperative pain score was higher in Group 1 than intervention groups (p = 0.006); however, there was no significant difference in intervention groups. The time to the first fentanyl request in Group 1 (79.44 ± 42.2) was significantly lower than Group 3 (206.38 ± 112.7; p = 0.001). The present study demonstrated that bilateral TAP block with 0.5% bupivacaine reduces post laparoscopic cholecystectomy pain intensity and fentanyl request and prolongs time to the first analgesic request. Adding sufentanil to the block solution reduced neither pain intensity nor fentanyl further consumption. Copyright © 2015. Published by Elsevier B.V.

  10. Transversus Abdominis Plane Block for Post Hysterectomy Pain: A Systematic Review and Meta-Analysis.

    PubMed

    Bacal, Vanessa; Rana, Urvi; McIsaac, Daniel I; Chen, Innie

    2018-04-30

    The objective of this study was to address the efficacy of transversus abdominis plane (TAP) blocks in pain management among women who undergo elective hysterectomy for benign pathology in both open and minimally invasive surgeries. We performed a systematic review by searching for bibliographic citations from Medline, Embase and Cochrane Library. MeSH headings for TAP blocks and hysterectomy were combined and restricted to the English language. We included RCTs comparing TAP blocks to placebo or no block in patients who underwent elective hysterectomy. Pain was measured using a visual analog score (VAS) on a scale of 0-100. We calculated pooled mean differences in VAS and total morphine consumption at 2 and 24 hours by performing a random effects meta-analysis. Fourteen studies met the inclusion criteria, comprising 855 participants. At 2 hours, mean VAS scores for patients who underwent TAP blocks were significantly lower after both total abdominal hysterectomy (TAH) (mean difference -14.97 [CI: -20.35- -9.59]) and total laparoscopic hysterectomy (TLH) (-18.16 [CI: -34.78- -1.53]) compared to placebo or no block. Pain scores at 24 hours for patients who underwent TAPB were significantly lower after both TAH (-10.09 [CI: -17.35- -2.83]) and TLH (-9.12 [CI: -18.12- -0.13]) compared to placebo or no block. Mean difference in morphine consumption was -9.53 mg (CI -15.43- -3.63) for TAH and -3.15 mg (CI: -8.41- 2.12) for TLH. In conclusion, TAP blocks provide significant postoperative early and delayed pain control compared to placebo or no block among women who undergo hysterectomy. There was reduced morphine consumption among patients who underwent TAH, but not after TLH. Copyright © 2018. Published by Elsevier Inc.

  11. Perioperative transversus abdominis plane (TAP) blocks for analgesia after abdominal surgery.

    PubMed

    Charlton, Shona; Cyna, Allan M; Middleton, Philippa; Griffiths, James D

    2010-12-08

    The transversus abdominis plane (TAP) block is a peripheral nerve block which anaesthetises the abdominal wall. The increasing use of TAP block, as a form of pain relief after abdominal surgery warrants evaluation of its effectiveness as an adjunctive technique to routine care and, when compared with other analgesic techniques. To assess effects of TAP blocks (and variants) on postoperative analgesia requirements after abdominal surgery. We searched specialised registers of Cochrane Anaesthesia and Cochrane Pain, Palliative and Supportive Care Review Groups, CENTRAL, MEDLINE, EMBASE and CINAHL to June 2010. We included randomised controlled trials (RCTs) comparing TAP block or rectus sheath block with: no TAP or rectus sheath block; placebo; systemic, epidural or any other analgesia. At least two review authors assessed study eligibility and risk of bias, and extracted data. We included eight studies (358 participants), five assessing TAP blocks, three assessing rectus sheath blocks; with moderate risk of bias overall. All studies had a background of general anaesthesia in both arms in most cases.Compared with no TAP block or saline placebo, TAP block resulted in significantly less postoperative requirement for morphine at 24 hours (mean difference (MD) -21.95 mg, 95% confidence interval (CI) -37.91 to 5.96; five studies, 236 participants) and 48 hours (MD -28.50, 95% CI -38.92 to -18.08; one study of 50 participants) but not at two hours (all random-effects analyses). Pain at rest was significantly reduced in two studies, but not a third.Only one of three included studies of rectus sheath blocks found a reduction in postoperative analgesic requirements in participants receiving blocks. One study, assessing number of participants who were pain-free after their surgery, found more participants who received a rectus sheath block to be pain-free for up to 10 hours postoperatively. As with TAP blocks, rectus sheath blocks made no apparent impact on nausea and vomiting

  12. The analgesic efficacy of subcostal transversus abdominis plane block with Mercedes incision.

    PubMed

    Guo, Jian-Guo; Li, Hui-Ling; Pei, Qing-Qing; Feng, Zhi-Ying

    2018-04-10

    Conventional perioperative analgesic modalities (e.g. opioids, epidural analgesia) have their own drawbacks, which limit their clinical application. This study investigated the opioid-sparing effectsof the oblique subcostal transversus abdominis plane (OSTAP) blockade with ropivacaine for the patients undergoing open liver resection with a Mercedes incision. 126 patients who were scheduled for open liver resection were enrolled in this study. Patients were randomly assigned to receive bilateral ultrasound-guided OSTAPblocks with either 0.375% ropivacaine (groupT) or 0.9% isotonic saline (group C). Both groups also received intravenous patient-controlled analgesia and intravenous 40 mg parecoxib every 12 h for a total of 3 days. Preoperative and intraoperative parameters, plus intraoperative and postoperative cumulative sufentanil consumption, were recorded. 70 patients were enrolled in the study finally. There were no significant differences between the two groups with respect to preoperative parameters, and surgical and anesthetic characteristics. The intraoperative sufentanil use, cumulative sufentanil consumption at 5 min after extubation, 2 h, 4 h,12 h and 24 h after operation in group T was significantly less than that in group C (P = 0.001, 0.001, 0.000, 0.000, 0.001 and 0.044, respectively). Compared with group C, postoperative NRS pain scores at rest were significantly lower at 2 h and 4 h postoperatively in group T (P = 0.04and 0.02, respectively); NRS scores at the time of coughing were also significantly lower in group T than in group C at all time points except 5 min after extubation (all P < 0.001). Furthermore, compared with group C, the number of intraoperative vasodilator use, the extubation time and the incidence of nausea was reduced in group T. Ultrasound-guided OSTAP block with ropivacaine can significantly decrease the perioperative cumulative dosage of analgesics and improve analgesic effect without obvious side

  13. [Ultrasound-guided Rectus Sheath Block vs Transversus Abdominis Plane Block in Children Undergoing Umbilical Hernia Repair].

    PubMed

    Torii, Naoko; Tachibana, Kazuya; Iwasaki, Mitsuo; Takeuchi, Muneyuki; Kinouchi, Keiko

    2016-06-01

    Although many reports describe the usefulness of the rectus sheath block (RSB) in the umbilical hernia repair, the efficacy of the transversus abdominis plane block (TAPB) is rarely reported. The purpose of this study was to compare the efficacy and technique of ultrasound-guided RSB and TAPB in children undergoing umbilical hernia repair. Thirty-four children younger than 12 years of age scheduled for umbilical hernia repair were enrolled in this prospective observer-blinded randomized clinical trial. They were randomly assigned either to RSB group (median age, 3.7 years) or TAPB group (median age, 3.8 years). After the induction of general anesthesia with sevoflurane, nitrous oxide, and oxygen children in both groups received regional anesthesia with 0.3 ml x kg(-1) of 0.25% ropivacaine on each side under ultrasound guidance. Hemodynamic changes at the skin incision, postoperative pain scores and parental satisfaction were recorded. Anesthesiologists rated the quality of ultrasound images and easiness of the block performance. The patients' demographics of the two groups were similar. There were no significant differences in the time needed for the block procedure, quality of ultrasound images and the change of the heart rate and blood pressure at the skin incision between the two groups. Postoperative pain score (immediately, 2 and 4 hours after the operation), need for rescue analgesia and satisfaction of the parents also did not differ. There were no major complications in the patients. TAPB provided comparable perioperative analgesia and easiness of block performance to RSB in the pediatric umbilical hernia repair.

  14. The analgesic efficacy of ultrasound-guided transversus abdominis plane block on postoperative pain and morphine consumption in varicocelectomy.

    PubMed

    Ömür, Dilek; Oğuzalp, Hüseyin; Kiraz, Hasan A; Ekin, Serpil; Alan, Cabir; Ersay, Ahmet R; Hancı, Volkan

    2016-06-01

    To evaluate the analgesic effect of transversus abdominis plane (TAP) block administered before varicocele surgery. This study was completed at the Faculty of Medicine, Çanakkale Onsekiz Mart University, Çanakkale, Turkey, between January 2011 and April 2013. In a prospective, double blind, randomized, placebo controlled clinical study, 40 male patients scheduled for elective varicocele operations were randomized to group T (treatment group) or group C (controls). After receiving general anesthesia, group T received a TAP block using 20 mL 0.25% bupivacaine on the operation side, whereas group C received a control block using 20 mL 0.9% Sodium chloride. During the first 24 hours after surgery, the patient pain was evaluated using the visual analogue scale (VAS) at rest and while coughing. Postoperative patient controlled analgesia morphine consumption, VAS scores, and side effects were recorded. Of 34 patients, Group T (n=18) had significantly lower VAS pain scores than Group C (n=16) both at rest and while coughing. The total morphine consumed was  lower (7.7 ± 4.0) versus 21.6 ± 12.4 mg, p less than 0.001) in the 24 hours after surgery. As part of a multimodal analgesic regime after varicocelectomy surgery, morphine consumption and VAS pain scores were significantly lower among those receiving 20 mL 0.25% bupivacaine administered for a TAP block than among controls.

  15. Rectus sheath and transversus abdominis plane blocks in children: a systematic review and meta-analysis of randomized trials.

    PubMed

    Hamill, James K; Rahiri, Jamie-Lee; Liley, Andrew; Hill, Andrew G

    2016-04-01

    The role of rectus sheath blocks (RSB) and transversus abdominis plane (TAP) blocks in pediatric surgery has not been well established. We aimed to determine if RSB and TAP blocks decrease postoperative pain and improve recovery in children. Duplicate searching of MEDLINE, EMBASE, Cochrane, Web of Science, and trial registries databases by two reviewers. Included were randomized trials in children on RSB or TAP block in abdominal operations, excluding inguinal procedures. Independent duplicate data extraction and quality assessment using a standardized form. Ten trials met inclusion criteria (n = 599), RSB in five and TAP block in five. A linear mixed effects model on patient level data from three trials showed nerve blocks lowered morphine requirements 6-8 h after surgery, -0.03 mg · kg(-1) (95% CI -0.05, -0.002). Pooled analysis of summary data showed nerve blocks lowered 0-10 scale pain scores immediately after the operation, -0.7 (95% CI -1.3, -0.1); lowered 4-16 scale pain scores, -2.0 (95% CI -2.3, -1.7); and delayed the time to first rescue analgesia, 17 min (95% CI 1.3, 33). Quality assessment showed some studies at moderate to high risk of bias. Abdominal wall blocks reduce pain and opiate use in children. We advise cautious interpretation of the results given the heterogeneity of studies. © 2016 John Wiley & Sons Ltd.

  16. Effectiveness of ultrasound-guided transversus abdominis plane block and rectus sheath block in pain control and recovery after gynecological transumbilical single-incision laparoscopic surgery.

    PubMed

    Mugita, M; Kawahara, R; Tamai, Y; Yamasaki, K; Okuno, S; Hanada, R; Inaoka, M; Funato, T

    2014-01-01

    To evaluate the effectiveness of ultrasound-guided transversus abdominis plane (TAP) and rectus sheath (RS) blocks in pain management and recovery after gynecological single-incision laparoscopic surgery (SILS). Abilateral TAP block (Group A, n = 9), bilateral TAP and RS blocks (Group B, n = 10), and a bilateral RS block (Group C, n = 9) with 40 ml ropivacaine per patient were conducted in 28 patients undergoing SILS for ovarian tumors. A pain score and walking distance in a 6-minute walk test (6MWT) were examined. Pain scores were significantly lower on postoperative day (POD) 3 than on POD 1 in Groups B (p = 0.03) and C (p = 0.02). The walking distance on POD 3 was comparable with that before surgery in Group C (p = 0.75), but shorter in Groups A (p = 0.004) and B (p = 0.02). The RS block alone was the most effective in relieving pain and accelerating general recovery after gynecological SILS.

  17. Clinical safety and effectiveness of transversus abdominis plane (TAP) block in post-operative analgesia: a systematic review and meta-analysis.

    PubMed

    Ma, Ning; Duncan, Joanna K; Scarfe, Anje J; Schuhmann, Susanne; Cameron, Alun L

    2017-06-01

    Transversus abdominis plane (TAP) blocks can provide analgesia postoperatively for a range of surgeries. Abundant clinical trials have assessed TAP block showing positive analgesic effects. This systematic review assesses safety and effectiveness outcomes of TAP block in all clinical settings, comparing with both active (standard care) and inactive (placebo) comparators. PubMed, EMBASE, The Cochrane Library and the University of York CRD databases were searched. RCTs were screened for their eligibility and assessed for risk of bias. Meta-analyses were performed on available data. TAP block showed an equivalent safety profile to all comparators in the incidence of nausea (OR = 1.07) and vomiting (OR = 0.81). TAP block was more effective in reducing morphine consumption [MD = 13.05, 95% CI (8.33, 51.23)] and in delaying time to first analgesic request [MD = 123.49, 95% CI (48.59, 198.39)]. Postoperative pain within 24 h was reduced or at least equivalent in TAP block compared to its comparators. Therefore, TAP block is a safe and effective procedure compared to standard care, placebo and other analgesic techniques. Further research is warranted to investigate whether the TAP block technique can be improved by optimizing dose and technique-related factors.

  18. Analgesic effects of ultrasound-guided transverse abdominis plane block using different volumes and concentrations of local analgesics after laparoscopic cholecystectomy.

    PubMed

    Şahin, Ayça Sultan; Ay, Necmiye; Şahbaz, Nuri Alper; Akay, Mehlika Kocabaş; Demiraran, Yavuz; Derbent, Abdurrahim

    2017-02-01

    Objective To evaluate the effects of an ultrasound-guided transverse abdominis plane (US-TAP) block used for postoperative pain relief by comparing the efficacy of two different volumes/concentrations of the local anaesthetic bupivacaine in patients undergoing laparoscopic cholecystectomies. Methods This randomized study enrolled patients undergoing laparoscopic cholecystectomies. They were randomized to two groups: group A received a 20 ml US-TAP block (50 mg bupivacaine +10 ml saline solution) and group B received a 30 ml US-TAP block (50 mg bupivacaine + 20 ml saline solution). The intraoperative consumption of remifentanil, the requirement for postoperative rescue analgesics, patient satisfaction scores, postoperative complications, and postoperative pain as measured by a visual analogue scale at 20 min, 12 h, and 24 h were recorded. Results A total of 60 patients enrolled in the study. There were no differences between the two groups with respect to demographic characteristics, duration of anaesthesia and patient satisfaction scores. The intraoperative consumption of remifentanil, postoperative VAS scores (20 min, 12 h and 24 h) and the requirement for postoperative analgesics were all significantly lower in group B who received a larger volume but a lower concentration of local anaesthetic solution compared with group A. Conclusion A US-TAP block can form part of a balanced postoperative analgesic regimen following laparoscopic cholecystectomy.

  19. Transversus abdominis plane block reduces postoperative pain intensity and analgesic consumption in elective cesarean delivery under general anesthesia.

    PubMed

    Eslamian, Laleh; Jalili, Zorvan; Jamal, Ashraf; Marsoosi, Vajiheh; Movafegh, Ali

    2012-06-01

    It is reported that following abdominal surgery, transversus abdominis plane (TAP) block can reduce postoperative pain. The primary outcome of this study was the evaluation of the efficacy of TAP block on pain intensity following cesarean delivery with Pfannenstiel incision. Fifty pregnant women were randomized blindly to receive either a TAP block with 15 ml 0.25% bupivacaine in both sides (group T, n = 25) or no blockade (group C, n = 25) at the end of the surgery, which was performed with a Pfannenstiel incision under general anesthesia. The pain intensity in the patients was assessed by a blinded investigator at the time of discharge from recovery and at 6, 12, and 24 h postoperatively, with a visual analogue scale (VAS) for pain. The women in the TAP block group had significantly lower VAS pain scores at rest and during coughing and consumed significantly less tramadol than the women in group C [50 mg (0-150) vs. 250 mg (0-400), P = 0.001]. There was a significantly longer time to the first request for analgesic in the TAP block group [210 min (0-300) vs. 30 min (10-180) in group C, P = 0.0001]. Two-sided TAP block with 0.25% bupivacaine in parturients who undergo cesarean section with a Pfannenstiel incision under general anesthesia can decrease postoperative pain and analgesic consumption. The time to the first analgesic rescue was longer in the parturients who received the TAP block.

  20. Postoperative analgesic efficiency of transversus abdominis plane block after ventral hernia repair: a prospective, randomized, controlled clinical trial.

    PubMed

    Chesov, Ion; Belîi, Adrian

    2017-10-01

    Effective postoperative analgesia is a key element in reducing postoperative morbidity, accelerating recovery and avoiding chronic postoperative pain. The aim of this study was to evaluate the effectiveness of ultrasound-guided Transversus Abdominis Plane (TAP) block, performed before surgical incision, in providing postoperative analgesia for patients undergoing open ventral hernia repair under general anaesthesia. Seventy elective patients scheduled for open ventral hernia repair surgery under general anaesthesia were divided randomly into two equal groups: Group I received bilateral TAP block performed before surgical incision (n = 35); Group II received systemic postoperative analgesia with parenteral opioid (morphine) alone (n = 35). Postoperatively pain scores at rest and with movement, total morphine consumption and opioid related side effects were recorded. Postoperative pain scores at rest and mobilization/cough were significantly higher in patients without TAP block (p < 0.05). Mean intraoperative fentanyl consumption was comparable between the two groups: 0.75 ± 0.31 mg in group I (TAP) and 0.86 ± 0.29 mg in group II (MO), p = 0.1299. Patients undergoing preincisional TAP block had reduced morphine requirements during the first 24 hours after surgery, compared to patients from group II, without TAP block (p = 0.0001). There was no difference in the incidence of opioid related side effects (nausea, vomiting) in the both groups during the first 24 postoperative hours. The use of preincisional ultrasound guided TAP block reduced the pain scores at rest and with movement/cough, opioid consumption and opioid-related side effects after ventral hernia repair when compared with opioid-only analgesia.

  1. Catheter tracking using continuous radial MRI.

    PubMed

    Rasche, V; Holz, D; Köhler, J; Proksa, R; Röschmann, P

    1997-06-01

    The guidance of minimally invasive procedures may become a very important future application of MRI. The guidance of interventions requires images of the anatomy as well as the information of the position of invasive devices used. This paper introduces continuous radial MRI for the simultaneous acquisition of the anatomic MR image and the position of one or more small RF-coils (mu-coils), which can be mounted on invasive devices such as catheters or biopsy needles. This approach allows the in-plane tracking of an invasive device without any prolongation of the overall acquisition time. The extension to three-dimensional position tracking is described. Phantom studies are presented demonstrating the capability of this technique for real-time automatic adjustment of the slice position to the current catheter position with a temporal resolution of 100 ms. Simultaneously the in-plane catheter position is depicted in the actually acquired MR image during continuous scanning.

  2. Magnetic Catheter Manipulation in the Interventional MRI Environment

    PubMed Central

    Wilson, Mark W.; Martin, Alastair B.; Lillaney, Prasheel; Losey, Aaron D.; Yee, Erin J.; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L.; Hetts, Steven W.

    2013-01-01

    Purpose To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional MRI environment. Materials and Methods Copper coils were mounted on the tips of commercially available 2.3 – 3.0 Fr microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (solenoid) and saddle-shaped (Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5T clinical MRI scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane utilizing a “real-time” steady-state free precession (SSFP) MRI sequence. Degree of deflection and catheter tip orientation were measured for each current application. Results The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Conclusion Controlled catheter deflection is possible with laser lithographed multi-axis coil tipped catheters in the MRI environment. PMID:23707097

  3. Chronological Changes in Ropivacaine Concentration and Analgesic Effects Between Transversus Abdominis Plane Block and Rectus Sheath Block.

    PubMed

    Murouchi, Takeshi; Iwasaki, Soshi; Yamakage, Michiaki

    2015-01-01

    Transversus abdominis plane block (TAPB) and rectus sheath block (RSB) are popular methods of controlling postoperative pain. Chronological changes in blood concentrations of local anesthetics have not been described, although a large amount of local anesthetic is required to block these compartments. We postulated that blood concentrations of anesthetics would peak earlier during TAPB than RSB (primary end point). Secondary end points were elapsed time from block until first postoperative rescue analgesia and affected dermatomes. This prospective, randomized study included 22 patients scheduled for laparoscopic ovarian surgery under general anesthesia. The patients were randomized to receive either a bilateral single-shot TAPB or a bilateral RSB (15 mL of 0.5% ropivacaine per side). Arterial blood was sampled 10, 20, 30, 45, 60, 90, and 120 minutes after ropivacaine administration. This trial was registered at the UMIN-Clinical Trials Registry (UMIN000012133) before patient recruitment. Arterial ropivacaine levels after block peaked earlier in the TAPB than in RSB [Tmax: 35 (12) vs 53 (16) minutes; P = 0.02], whereas peak ropivacaine concentrations did not significantly differ between the groups [Cmax: 1.83 (0.41) vs 1.79 (0.33) μg/mL; P = 0.54]. Peak ropivacaine concentrations exceeded 2.2 μg/mL in 1 and 2 patients in the RSB and TAPB groups, respectively, although symptoms of local anesthetic systemic toxicity were not evident in any of them. The median [interquartile range] duration of analgesia was significantly longer for TAPB than RSB (421 [335-536] vs 196 [168-277] minutes; P = 0.01). Peak ropivacaine concentrations were comparable during TAPB and RSB, but peaked earlier during TAPB. Although 150 mg of ropivacaine remained effective significantly longer during TAPB than RSB during laparoscopic surgery, this dose could cause local anesthetic systemic toxicity. The analgesic effects of blocks with less ropivacaine should be assessed.

  4. Transversus Abdominis Plane Blockade as Part of a Multimodal Postoperative Analgesia Plan in Patients Undergoing Radical Cystectomy.

    PubMed

    Matulewicz, Richard S; Patel, Mehul; Jordan, Brian J; Morano, Jacqueline; Frainey, Brendan; Bhanji, Yasin; Bux, Mahreen; Nader, Antoun; Kundu, Shilajit D; Meeks, Joshua J

    2018-04-26

    Radical cystectomy (RC) is a morbid procedure with frequent complications that may benefit from implementation of an enhanced recovery after surgery (ERAS) protocol. To examine the benefits of a multimodal analgesic plan that uses continuous transversus abdominis plane (TAP) blockade as part of an ERAS protocol after RC. A retrospective comparison of consecutive patients undergoing RC over a 4-year period was conducted. Patients were designated as having surgery either before or after implementation of an ERAS protocol. A major component of the ERAS protocol was a multi-modal analgesia plan with TAP blockade. Patient demographics, comorbidities, operative details, and outcomes, including days to flatus, bowel movement (BM), narcotic usage, and length of stay (LOS) were compared. In total, 171 patients were included: 100 pre-ERAS and 71 ERAS. There were no differences in age, smoking status, operative approach, or diversion type. The patients in the ERAS cohort were less likely to be male, had a higher median BMI, and more likely to have received neoadjuvant chemotherapy. Total and early postoperative narcotic use were lower in the ERAS cohort: 89 vs. 336 mg ( p  < 0.001) and 62 vs 203 mg ( p  = 0.001), respectively. The ERAS cohort had fewer days to flatus (3 vs. 4, p  < 0.001) and fewer days to bowel movement (4 vs. 5, p  < 0.001). Median LOS was shorter in the ERAS cohort (7 vs. 8.5d, p  = 0.001). There were no differences in complications or readmission rates between the two cohorts. TAP blockade as part of an ERAS multi-modal pain plan is associated with low narcotic usage, and significant improvement in time to flatus, BM, and LOS compared to traditional post-RC pain management.

  5. Levobupivacaine-dextran mixture for transversus abdominis plane block and rectus sheath block in patients undergoing laparoscopic colectomy: a randomised controlled trial.

    PubMed

    Hamada, T; Tsuchiya, M; Mizutani, K; Takahashi, R; Muguruma, K; Maeda, K; Ueda, W; Nishikawa, K

    2016-04-01

    We performed a randomised controlled double-blinded study of patients having laparoscopic colectomy with bilateral transversus abdominis plane block plus rectus sheath block, comparing a control group receiving 80 ml levobupivacaine 0.2% in saline with a dextran group receiving 80 ml levobupivacaine 0.2% in 8% low-molecular weight dextran. Twenty-seven patients were studied in each group. The mean (SD) maximum plasma concentration of levobupivacaine in the control group (1410 (322) ng.ml(-1) ) was higher than the dextran group (1141 (287) ng.ml(-1) ; p = 0.004), and was reached more quickly (50.6 (30.2) min vs 73.2 (24.6) min; p = 0.006). The area under the plasma concentration-time curve from 0 min to 240 min in the control group (229,124 (87,254) ng.min.ml(-1) ) was larger than in the dextran group (172,484 (50,502) ng.min.ml(-1) ; p = 0.007). The median (IQR [range]) of the summated numerical pain rating score at rest during the first postoperative 24 h in the control group (16 (9-20 [3-31]) was higher than in the dextran group (8 (2-11 [0-18]); p = 0.0001). In this study, adding dextran to levobupivacaine decreased the risk of levobupivacaine toxicity while providing better analgesia. © 2016 The Association of Anaesthetists of Great Britain and Ireland.

  6. "Transversus Abdominis Plane Blocks in Microsurgical Breast Reconstruction: Analysis of Pain, Narcotic Consumption, Length of Stay and Cost."

    PubMed

    Salibian, Ara A; Frey, Jordan D; Thanik, Vishal D; Karp, Nolan S; Choi, Mihye

    2018-06-02

    Transversus abdominis plane (TAP) blocks are increasingly being utilized in microvascular breast reconstruction. The implications of TAP blocks on specific reconstructive, patient and institutional outcomes remain to be fully elucidated. Patients undergoing abdominally-based microvascular breast reconstruction from 2015-2017 were reviewed. Length of stay, complications, narcotic consumption, donor-site pain and hospital expenses were compared between patients that did and those that did not receive TAP blocks with liposomal bupivacaine. Outcomes were subsequently compared in patients with elevated body mass index (BMI). Fifty patients (43.9%) received TAP blocks (27 [54.0%] under ultrasound guidance) and 64 patients (56.1%) did not. Patients with TAP blocks had significantly decreased oral and total narcotic consumption (p=0.0001 and p<0.0001, respectively) as well as significantly less donor-site pain (3.3 versus 4.3, p<0.0001). There was no significant difference in hospital expenses between the two cohorts ($21,531.53 versus $22,050.15 per patient, p=0.5659). Patients with BMI≥25 who received TAP blocks had a significantly decreased length of stay (3.8 versus 4.4 days, p=0.0345) as well as decreased narcotic consumption and postoperative pain compared to patients without TAP blocks. Patients with BMI<25 did not have a significant difference in postoperative pain, narcotic consumption or length of stay between the TAP versus no TAP block groups. TAP blocks with liposomal bupivacaine significantly reduce oral and total postoperative narcotic consumption as well as donor-site pain in all patients after abdominally-based microvascular breast reconstruction without increasing hospital expenses. TAP blocks additionally significantly decrease length of stay in patients with BMI≥25.

  7. Comparison of bilateral transversus abdominis plane block and wound infiltration with bupivacaine for postoperative analgesia after cesarean delivery.

    PubMed

    Görkem, Ümit; Koçyiğit, Kamuran; Toğrul, Cihan; Güngör, Tayfun

    2017-03-15

    The study aimed to compare efficacy, safety, pain intensity and analgesic consumption in patients receiving either bilateral transversus abdominis plane (TAP) block or wound infiltration with bupivacaine after cesarean delivery (CD). A total of 216 parturient women undergoing CD under general anesthesia were randomly allocated into five groups: i) controls (group 1), ii) TAP placebo (group 2), iii) TAP (group 3), iv) wound infiltration placebo (group 4), and, v) wound infiltration (group 5). Pain intensity was assessed using a visual analogue scale (VAS). Analgesic consumptions were recorded by a blinded nurse at 6, 12, and 18 hours postoperatively. The baseline characteristics of the five groups were similar in terms of age, history of CD, and body mass indices (p>0.05). There were significant intergroup differences in VAS scores between all groups at the zero time-point (p=0.03), at the 6th hour (p=0.02), 12th hour (p=0.02), and at the 18th hour (p=0.02). Group 3 patients had lower pain scores and consumed less diclofenac than group 2 patients only within 12 hours postoperatively whereas pain intensity and analgesic consumption were not different between group 5 and group 4 patients. Group 5 patients received significantly less pethidine than group 4 and group 1 patients (p<0.001). TAP block provided better pain relief and less analgesic requirement than bupivacaine wound infiltration early after CD. Given the similar amounts of diclofenac but lower amounts of pethidine administered in the wound infiltration group, wound infiltration of bupivacaine seems promising in terms of reducing opioid use after CD under general anesthesia, especially when TAP block is not used.

  8. Effect of Transversus Abdominis Plane Block on Postoperative Pain after Colorectal Surgery: A Meta-Analysis of Randomized Controlled Trials.

    PubMed

    Liu, Lin; Xie, Yan-Hu; Zhang, Wei; Chai, Xiao-Qing

    2018-01-01

    To assess the analgesic efficacy of transversus abdominis plane (TAP) block in patients undergoing colorectal surgery (CRS). The databases of PubMed, ISI Web of Science, and Embase were searched, and randomized controlled studies (RCTs) that compared TAP block to control for relief of postoperative pain in patients who underwent CRS were included. Outcomes, including postoperative pain at rest and with movement, morphine use, postoperative nausea and vomiting, and the length of hospital stay, were analyzed using STATA software. The weighted mean differences (WMDs) with 95% confidence intervals (95% CIs) or relative risk with 95% CI were used to present the strength of associations. A total of 7 RCTs with 511 patients were included. The results of this study suggested that TAP block significantly relieved postoperative pain during postanesthetic recovery after CRS at rest and during movement (WMDs were -0.98 [95% CI -1.57 to -0.38] and -0.68 [-1.07 to -0.30], respectively), and also decreased pain intensity during movement 24 h after CRS (WMD: -0.57 [95% CI -1.06 to -0.08]). TAP block significantly reduced opioid consumption within 24 h when compared to controls, with a WMD of 15.66 (95% CI -23.93 to -7.39). However, TAP block did not shorten the length of hospital stay. TAP block was an effective approach for relief of postoperative pain and reduced postoperative consumption of morphine. More RCTs with large sample sizes are required to confirm these findings. © 2018 The Author(s) Published by S. Karger AG, Basel.

  9. Rectus abdominis overuse injury in a tennis athlete treated with traumeel.

    PubMed

    Natsis, Konstantinos; Lyrtzis, Christos; Papathanasiou, Efthymia; Anastasopoulos, Nikos

    2012-01-01

    Rectus abdominis injuries are common in tennis players at all levels of competition. Traumeel(®) injection can be used for treatment of muscle strains and hematomas. A 21-year-old female tennis athlete was injured on the non-dominant rectus abdominis during the cocking phase of the service motion. She suffered from pain and tenderness. One week later, during a serve, she experienced severe pain on the contralateral side of her abdomen. Conservative treatment was performed by the team physician with rest, ice therapy and analgesics for 20 days, but she had recurrent injuries. The ultrasonography and MRI showed hematoma of the rectus abdominis muscle. She was treated with 2 injections of Traumeel(®) on the 2(nd), 4(th), 6(th) post-traumatic day and received 1 injection on the 10(th) post-traumatic day. She also modified her serve technique. On the fourth post-treatment week the athlete had pain-free function and both the MRI appearance and the size of rectus abdominal muscle were normal. She returned to her sport activities. There is no recurrence of her injury 2 years later. Rectus abdominis hematoma must be diagnosed early. Traumeel(®) injections are effective, safe and well-tolerated for the treatment of overuse injury of the rectus abdominis following strain.

  10. Rectus abdominis atrophy after ventral abdominal incisions: midline versus chevron.

    PubMed

    Vigneswaran, Y; Poli, E; Talamonti, M S; Haggerty, S P; Linn, J G; Ujiki, M B

    2017-08-01

    Although many outcomes have been compared between a midline and chevron incision, this is the first study to examine rectus abdominis atrophy after these two types of incisions. Patients undergoing open pancreaticobiliary surgery between 2007 and 2011 at our single institution were included in this study. Rectus abdominis muscle thickness was measured on both preoperative and follow-up computed tomography (CT) scans to calculate percent atrophy of the muscle after surgery. At average follow-up of 24.5 and 19.0 months, respectively, rectus abdominis atrophy was 18.9% greater in the chevron (n = 30) than in the midline (n = 180) group (21.8 vs. 2.9%, p < 0.0001). Half the patients with a chevron incision had >20% atrophy at follow-up compared with 10% with a midline incision [odds ratio (OR) 9.0, p < 0.0001]. No significant difference was observed in incisional hernia rates or wound infections between groups. In this study, chevron incisions resulted in seven times more atrophy of the rectus abdominis compared with midline incisions. The long-term effects of transecting the rectus abdominis and disrupting its innervation creates challenging abdominal wall pathology. Atrophy of the abdominal wall can not be readily fixed with an operation, and this significant side effect of a transverse incision should be factored into the surgeon's decision-making process when choosing a transverse over a midline incision.

  11. Magnetic catheter manipulation in the interventional MR imaging environment.

    PubMed

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  12. Endoscopic Rectus Abdominis and Prepubic Aponeurosis Repairs for Treatment of Athletic Pubalgia.

    PubMed

    Matsuda, Dean K; Matsuda, Nicole A; Head, Rachel; Tivorsak, Tanya

    2017-02-01

    Review of the English orthopaedic literature reveals no prior report of endoscopic repair of rectus abdominis tears and/or prepubic aponeurosis detachment. This technical report describes endoscopic reattachment of an avulsed prepubic aponeurosis and endoscopic repair of a vertical rectus abdominis tear immediately after endoscopic pubic symphysectomy for coexistent recalcitrant osteitis pubis as a single-stage outpatient surgery. Endoscopic rectus abdominis repair and prepubic aponeurosis repair are feasible surgeries that complement endoscopic pubic symphysectomy for patients with concurrent osteitis pubis and expand the less invasive options for patients with athletic pubalgia.

  13. Postoperative Analgesia by a Transversus Abdominis Plane Block Using Different Concentrations of Ropivacaine for Abdominal Surgery: A Meta-Analysis.

    PubMed

    Sun, Ni; Wang, Shouyong; Ma, Pengpeng; Liu, Shuting; Shao, Aijie; Xiong, Ling

    2017-09-01

    Transversus abdominis plane block (TAPB) has been proven to be an effective means of postoperative anesthesia, but the optimum effective concentration of ropivacaine warrants further research. This study aimed to identify the optimal ropivacaine concentration of TAPB using a meta-analysis. This study consisted of a meta-analysis of randomized controlled trials (RCTs). We searched online databases, including PubMed, Embase, the Cochrane Database of Systematic Reviews, and Web of Science. RCTs investigating the 24-hour postoperative opioid consumption and the rest and dynamic pain scores 2, 12, and 24 hours after surgery were included in this analysis. We also assessed opioid-related side-effects and patient satisfaction 24 hours after surgery. Nineteen RCTs (1217 patients) were included in this meta-analysis, which showed that only TAPB with 0.375% and 0.5% ropivacaine was able to reduce opioid consumption 24 hours after surgery by weighted mean differences of -6.55 and -4.44 mg (morphine IV equivalents), respectively (P<0.05). A meta-regression analysis did not reveal an association between the local anesthetic dose (in mg), surgery, anesthesia, block timing, and the TAPB effect on opioid consumption. Ropivacaine concentrations of 0.375% and 0.5% reduced the 2-hour postoperative pain score and reduced the incidence of nausea and vomiting, but this analgesic effect disappeared at 12 and 24 hours. Only TAPB with 0.375% ropivacaine improved the degree of satisfaction 24 hours after surgery (weighted mean difference of 0.87 [0.08-1.66], P=0.03). In terms of efficacy and safety, the use of 0.375% ropivacaine for TAPB is preferred in the clinical work.

  14. Effect of adding dexamethasone to bupivacaine on transversus abdominis plane block for abdominal hysterectomy: A prospective randomized controlled trial

    PubMed Central

    Ammar, Amany S.; Mahmoud, Khaled M.

    2012-01-01

    Purpose: Different adjuvants have been used to improve the quality and increase the duration of local anesthetics during various nerve block techniques. The current study was aimed to evaluate the effect of adding dexamethasone to bupivacaine on the quality and duration of transversus abdominis plane (TAP) block. Methods: Sixty adult patients undergoing elective open abdominal hysterectomy were randomly allocated to receive TAP block using 20 mL of bupivacaine hydrochloride 0.25% + 2 mL saline 0.9% (control group, n=30) or 20 mL of bupivacaine hydrochloride 0.25% + 2 mL dexamethasone “8 mg” (dexamethasone group, n=30). The primary outcome was postoperative pain, as evaluated by visual analog scale (VAS) for pain scoring at 1, 2, 4, 12, 24 and 48 h postoperatively, whereas the secondary outcomes were time to first analgesia (TFA), morphine consumption and the occurrence of nausea, vomiting or somnolence. Results: The pain VAS score was significantly lower at the postoperative 2 h (4.9 vs. 28.1, P=0.01), 4 h (12.2 vs. 31.1, P=0.01) and 12 h (15.7 vs. 25.4, P=0.02). Furthermore, TFA was significantly longer in the dexamethasone group (459.8 vs. 325.4 min, P=0.002), with lesser morphine requirements in the postoperative 48 h (4.9 vs. 21.2 mg, P=0.003) and lower incidence of nausea and vomiting (6 vs. 14, P=0.03). No complications attributed to the block were recorded. Conclusion: Addition of dexamethasone to bupivacaine in TAP block prolonged the duration of the block and decreased the incidence of nausea and vomiting. PMID:23162395

  15. The efficacy of oblique subcostal transversus abdominis plane block in laparoscopic cholecystectomy - a prospective, placebo controlled study.

    PubMed

    Breazu, Caius Mihai; Ciobanu, Lidia; Hadade, Adina; Bartos, Adrian; Mitre, Călin; Mircea, Petru Adrian; Ionescu, Daniela

    2016-04-01

    Pain control after a laparoscopic cholecystectomy can represent a challenge, considering the side effects due to standard analgesia methods. Recently the transversus abdominis plane block (TAP Block) has been used as a part of multimodal analgesia with promising results. The subcostal approach (OSTAP Block), a variant on the TAP block, produces reliable unilateral supraumbilical analgesia. This study evaluated the efficacy of the OSTAP block with bupivacaine in laparoscopic cholecystectomy compared with the placebo OSTAP block. Sixty ASA I/II adult patients listed for elective laparoscopic cholecystectomy were randomly allocated in one of two groups: Group A (OSTAP placebo) received preoperatively bilateral OSTAP block with sterile normal saline and Group B (OSTAP bupivacaine) received bilateral preoperatively OSTAP block with the same volumes of 0.25% bupivacaine. Twenty-four hours postoperative opioid consumption, the dose of opioid required during surgery, opioid dose in the recovery unit (PACU) and PACU length of stay were evaluated. The quality of analgesia was assessed by the Visual Analogue Scale (VAS) at specific interval hours during 24 h, at rest and with movement. The mean intraoperative opioid consumption showed a significant difference between the two groups, (385 ± 72.52 mg in group A vs 173.67 ± 48.60 mg in group B, p < 0.001). The mean 24 h opioid consumption showed a statistically significant difference between groups (32 ± 26.05 mg vs 79 ± 16.68 mg, p < 0.001). PACU length of stay was significantly lower for group B patients compared with group A patients (20.67 ± 11.27 min vs 41.67 ± 12.41 min, p < 0.001). The OSTAP bupivacaine group had a statistically significant lower pain score than the OSTAP placebo group at 0, 2, 4, 6, 12, 24 h, both at rest and with movement. No signs or symptoms of local anaesthetic systemic toxicity or other complications were detected. OSTAP block with bupivacaine 0.25% can provide effective analgesia up to 24

  16. High-dose versus low-dose local anaesthetic for transversus abdominis plane block post-Caesarean delivery analgesia: a meta-analysis.

    PubMed

    Ng, S C; Habib, A S; Sodha, S; Carvalho, B; Sultan, P

    2018-02-01

    The optimal local-anaesthetic (LA) dose for transversus-abdominis-plane (TAP) block is unclear. In this meta-analysis, we aimed to determine whether TAP blocks for Caesarean delivery (CD) with low-dose (LD) LA demonstrated non-inferiority in terms of analgesic efficacy, compared with high-dose (HD) LA. A literature search was performed for randomised controlled trials examining the analgesic efficacy of TAP blocks vs control after CD. The different dosing used in these studies was classified as HD or LD (bupivacaine equivalents >50 or ≤50 mg per block side, respectively). The pooled results of each dose group vs control were indirectly compared using the Q test. The primary outcome was 24 h opioid consumption. Secondary outcomes included 6 and 24 h postoperative pain scores, time to first analgesia, 6 h opioid consumption, opioid-related side-effects, and maternal satisfaction. Fourteen studies consisting of 770 women (389 TAP and 381 control) were included. Compared with controls, the 24 h opioid consumption (milligram morphine equivalents) was lower in HD [mean difference (MD) 95% confidence interval (CI) -22.41 (-38.56, -6.26); P=0.007; I 2 =93%] and LD [MD 95% CI -16.29 (-29.74, -2.84); P=0.02; I 2 =98%] TAP groups. However, no differences were demonstrated between the HD and LD groups (P=0.57). There were also no differences between the HD and LD groups for the 6 h opioid consumption, time to first analgesia, 6 and 24 h pain scores, postoperative nausea and vomiting, pruritus, and maternal satisfaction. Low-dose TAP blocks for Caesarean delivery provide analgesia and opioid-sparing effects comparable with the high-dose blocks. This suggests that lower doses can be used to reduce local anaesthetic toxicity risk without compromising the analgesic efficacy. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  17. Pethidine efficacy in achieving the ultrasound-guided oblique subcostal transversus abdominis plane block in laparoscopic cholecystectomy: A prospective study.

    PubMed

    Breazu, Caius Mihai; Ciobanu, Lidia; Bartos, Adrian; Bodea, Raluca; Mircea, Petru Adrian; Ionescu, Daniela

    2017-02-21

    Pethidine is a synthetic opioid with local anesthetic properties. Our goal was to evaluate the analgesic efficacy of pethidine for achieving the ultrasound-guided oblique subcostal transversus abdominis plane (OSTAP) block in laparoscopic cholecystectomy. This prospective, double-blind study included 79 patients of physical status I and II according to American Society of Anesthesiologists, scheduled for elective laparoscopic cholecystectomy. The patients were randomly allocated into three groups, depending on the drug used to achieve preoperative bilateral OSTAP block: 1) OSTAP-Placebo (treated with normal saline); 2) OSTAP-Bupivacaine (treated with 0.25% bupivacaine); and 3) OSTAP-Pethidine (treated with 1% pethidine). The efficacy of pethidine in achieving the OSTAP block was analyzed using visual analog scale (VAS), intraoperative opioid dose, opioid consumption in post anesthesia care unit, and opioid consumption in the first 24 postoperative hours. The pain scores assessed by VAS at 0, 2, 4, 6, 12, and 24 hours were significantly lower in OSTAP-Pethidine than in OSTAP-Placebo group (p < 0.001). The mean intraoperative opioid consumption was significantly lower in OSTAP-Pethidine compared to OSTAP-Placebo group (150 versus 400 mg, p < 0.001), as well as the mean opioid consumption in the first 24 hours (20.4 versus 78 mg, p < 0.001). Comparing VAS assessment between OSTAP-Bupivacaine and OSTAP-Pethidine groups, statistically significant differences were observed only for the immediate postoperative pain assessment (0 hours), where lower values were observed in OSTAP-Pethidine group (p = 0.004). There were no statistically significant differences in the incidence of postoperative nausea and vomiting (p = 0.131) between the groups. The use of 1% pethidine can be an alternative to 0.25% bupivacaine in achieving OSTAP block for laparoscopic cholecystectomy.

  18. A Comparative Study of Analgesic Efficacy of Intrathecal Buprenorphine with Ultrasound-Guided Transversus Abdominis Plane Block for Postcesarean Delivery Analgesia.

    PubMed

    Marappa, Prakash; Chikkapillappa, Manjunath Abloodu; Chennappa, Nagaraj Mungasuvalli; Pujari, Vinayak Seenappa

    2017-01-01

    Women undergoing cesarean (CS) delivery present a unique set of challenges to the anesthetist in terms of postoperative pain management. This study was conducted to compare the analgesic efficacy of intrathecal buprenorphine (ITB) with ultrasound-guided transversus abdominis plane (TAP) block in post-CS delivery pain. A prospective randomized comparative study of sixty American Society of Anesthesiologists physical status I and II pregnant patients divided into two groups of thirty each as ITB group and TAP block group after satisfying the inclusion criteria. In the present study, demographic data were comparable between both groups. The time to first analgesic request was significantly longer in ITB group (389.67 ± 90.78 min) compared to TAP group (669.17 ± 140.65 min) and was statistically significant, P < 0.001. The mean paracetamol consumption in the first 24 h was higher in the TAP group (3.5 g) compared to the ITB group (1.13 g) and was statistically significant, P < 0.0001, and the mean tramadol consumed in first 24 h was higher in the TAP (46.66 mg) group as compared to the ITB group (16.66 mg) and was statistically significant, P < 0.001. The mean visual analog scale scores assessed at 4, 6, 12, and 24 h was higher in the TAP group and was statistically significant, P < 0.001. Our study showed that patients receiving ITB for post-CS pain management reported longer duration of analgesia, lower pain scores, and lower analgesic consumption during the first 24 h. The benefits of neuraxial opiates are significant and far outweigh the side effects.

  19. [Efficiency of bupivacaine and association with dexmedetomidine in transversus abdominis plane block ultrasound guided in postoperative pain of abdominal surgery].

    PubMed

    Aksu, Recep; Patmano, Gülçin; Biçer, Cihangir; Emek, Ertan; Çoruh, Aliye Esmaoğlu

    We aimed to evaluate the effect of bupivacaine and dexmedetomidine added to bupivacaine used in tranversus abdominis plane (TAP) block on postoperative pain and patient satisfaction in patients undergoing lower abdominal surgery. Patients submitted to lower abdominal surgery were enrolled in the study. After anesthesia induction, ultrasound guided TAP block was performed. TAP block was obtained with 21mL 0.9% saline in Group C (n=31), 20mL 0.5% bupivacaine+1mL saline in Group B (n=31), and 20mL 0.5% bupivacaine+1mL dexmedetomidine (100μg) in Group BD (n=31). Visual analog scale scores were lower in Group BD compared to Group C, at all time points (p<0.05); it was lower in group BD than in group B at 10-24h. In Group B, it was lower than Group C at 2-8h (p<0.05). Total morphine consumption was lower in Group BD compared to other groups and lower in group B than in the controls (p<0.001). Patient satisfaction was higher in Group BD than in other groups and was higher in both study groups than in the controls (p<0.001). Nausea-vomiting scores, antiemetic requirement, or additional analgesic administration were not significant among groups (p>0.05). The addition of dexmedetomidine to bupivacaine on TAP block decreased postoperative pain scores and morphine consumption; it also increased patient satisfaction in patients undergoing lower abdominal surgery. Dexmedetomidine did not have any effect on nausea and vomiting score and antiemetic requirement. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. Ultrasound-guided rectus sheath and transversus abdominis plane blocks for perioperative analgesia in upper abdominal surgery: A randomized controlled study.

    PubMed

    Abdelsalam, Khaled; Mohamdin, O W

    2016-01-01

    Regional anesthetic techniques can be used to alleviate postoperative pain in patients undergoing major upper abdominal surgery. Our aim was to evaluate the efficacy of bilateral ultrasound (US)-guided rectus sheath (RS) and transversus abdominis plane (TAP) blocks for better perioperative analgesia. It is a prospective, observer-blinded, randomized clinical study. 40 eligible patients undergoing elective liver resection or Whipple procedure were included. All patients received a standardized anesthetic technique. Group 1 (n = 20) received preincisional US-guided bilateral RS and TAP blocks using 20 ml volume of bupivacaine 0.25% for each, and group 2 (n = 20) received local wound infiltration at end of surgery with 40 ml of bupivacaine 0.25%. A standardized postoperative analgesic regimen composed of intravenous paracetamol and a morphine patient-controlled analgesia (PCA). The use of intraoperative fentanyl and recovery room morphine boluses, PCA-administered morphine, pain scores as well as number of patients' experienced postoperative nausea and vomiting in the ward at 6 and 24 h were recorded. Group 1 patients received a significantly lower cumulative intraoperative fentanyl, significantly lesser boluses of morphine in postanesthesia care unit, as well, significantly lower cumulative 24 h postoperative morphine dosage than the group 2 patients. Pain visual analog scale scores were significantly lower at both 6 and 24 h postoperatively in TAP group when compared with the no-TAP group. There were no complications related to the TAP block procedures. No signs or symptoms of local anesthetic systemic toxicity were detected. The combination of bilateral US-guided RS and TAP blocks provides excellent perioperative analgesia for major upper abdominal surgery.

  1. Accuracy of external ventricular drainage catheter placement.

    PubMed

    Abdoh, Mohammad Ghazi; Bekaert, Olivier; Hodel, Jérôme; Diarra, Salia Mamadou; Le Guerinel, Caroline; Nseir, Rémi; Bastuji-Garin, Sylvie; Decq, Philippe

    2012-01-01

    External ventricular drainage (EVD) is a freehand neurosurgical procedure performed routinely using the anatomical landmarks. The aim of this study was to determine the accuracy of EVD catheter freehand placement. Pre-operative and post-operative computed tomography scans for 66 consecutive EVDs performed in 56 adult patients (26 men, 30 women) in 2008 were retrospectively reviewed. Etiologies of acute hydrocephalus were subarachnoid or intraventricular haemorrhage (43 cases) or miscellaneous (13 cases). Pre-operative lateral ventricular volume, position of the burr hole, length of the catheter and its sagittal and coronal angular variations from a theoretical trajectory were measured. The EVD was placed on the right (53 cases) or left (13 cases) side. The mean pre-operative lateral ventricular volume was 51 cc (10-118 cc). The average distance from the burr hole to the midline was 28 mm (10-49 mm) and to the supra-orbital ridge was 101 mm (75-125 mm). The mean intracranial catheter length was 60 mm (from 39-102 mm). Only 50% of the EVDs in the coronal plane and 40% in the sagittal plane were placed with an angular variation of ±5° to the target. The tip was placed outside of the ventricles in three cases; 13 catheters crossed the midline, and five intracranial minor haemorrhages were detected. Freehand placement of EVDs does not have sufficient accuracy and may lead to drainage dysfunctions. This data suggests that a guidance system for EVD's would be required.

  2. Ultrasound-guided transversus abdominis plane block for postoperative analgesia in living liver donors: A prospective, randomized, double-blinded clinical trial.

    PubMed

    Kıtlık, Arzu; Erdogan, Mehmet Ali; Ozgul, Ulku; Aydogan, Mustafa Said; Ucar, Muharrem; Toprak, Huseyin Ilksen; Colak, Cemil; Durmus, Mahmut

    2017-02-01

    Transversus abdominis plane (TAP) block is a peripheral nerve block that reduces postoperative pain, nausea, vomiting and the need for postoperative opioids following various types of abdominal surgery. The primary aim of the present study was to evaluate the effects of TAP block on postoperative analgesia and opioid consumption in living liver donors in whom a right "J" abdominal incision was used. This prospective, double-blinded, randomized controlled study was conducted with 50 living liver donors, aged 18-65years, who were scheduled to undergo right hepatectomy. Patients who received ultrasonography-guided subcostal TAP block were allocated into Group 1, and patients who did not receive TAP block were allocated into Group 2. The TAP blocks were performed bilaterally at the conclusion of surgery using 1.5mg∗kg -1 bupivacaine diluted with saline to reach a total volume of 40mL. For each patient, morphine consumption, pain scores at rest and movement, sedation scores, nausea, vomiting and the need for antiemetic medication were assessed at 0, 2, 4, 6, 12 and 24h postoperatively by researchers who were blinded to the study groups. Morphine consumption was significantly lower in Group 1 than in Group 2 at the 2nd, 6th and 24th hours (P<0.05). The mean total morphine consumption values after 24h were 40mg and 65mg in Groups 1 and 2, respectively. The TAP block significantly reduced postoperative visual analog scale pain scores both at rest and during movement at 0, 2, 4, 6, and 24h postoperatively (P<0.05). The TAP block reduced 24-h postoperative morphine consumption and contributed to analgesia in living liver donors who underwent upper abdominal wall incisions. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Evaluation of transversus abdominis plane block for renal transplant recipients - A meta-analysis and trial sequential analysis of published studies.

    PubMed

    Singh, Preet Mohinder; Borle, Anuradha; Makkar, Jeetinder Kaur; Trisha, Aanjan; Sinha, Aashish

    2018-01-01

    Patients undergoing renal transplant (RT) have altered drug/opioid pharmacokinetics. Transversus abdominis plane (TAP) block in renal transplant recipients has been recently evaluated for analgesic and opioid-sparing potential by many trials. The studies comparing TAP-block to conventional analgesic regimens for RT were searched. Comparisons were made for total opioids consumed (as morphine-equivalents) during the first postoperative 24-h (primary objective), intraoperative, and immediate-postoperative period. Pain scores and postoperative nausea-vomiting (PONV) were also evaluated. Trial sequential analysis (TSA) was used to quantify the strength of analysis. Ten-trials with 258 and 237 patients in control and TAP-block group, respectively, were included. TAP-block decreased the 24-h (reported in 9-trials) opioid consumption by 14.61 ± 4.34 mg (reduction by 42.7%, random-effects, P < 0.001, I 2 = 97.82%). Sample size of the present analysis (472) was well past the required "information-size" variable (396) as per the TSA for a power of 85%. Intraoperative opioid consumption also decreased by 2.06 ± 0.63 mg (reduction of 27.8%) (random effects, P < 0.001, I 2 = 98.84%). Pain scores with TAP-block were significantly lower in both early and delayed postoperative phase. Odds ratio for PONV without TAP block was 1.99 ± 1.05 (Fixed-effects, P = 0.04, I 2 = 0%). Publication bias was likely (Egger's test, X-intercept=7.89, P < 0.05). TAP-block significantly lowers the intraoperative and cumulative postoperative 24-h opioid consumption in RT recipients. Persistent and better pain control is achieved when TAP-Block is used. Benefits of TAP block extend beyond the analgesic actions alone as it also decreases the 24-h incidence of postoperative nausea vomiting as well. The technique of the block needs standardization for RT recipients.

  4. Comparison of Transversus Abdominis Plane Infiltration with Liposomal Bupivacaine versus Continuous Epidural Analgesia versus Intravenous Opioid Analgesia.

    PubMed

    Ayad, Sabry; Babazade, Rovnat; Elsharkawy, Hesham; Nadar, Vinayak; Lokhande, Chetan; Makarova, Natalya; Khanna, Rashi; Sessler, Daniel I; Turan, Alparslan

    2016-01-01

    Epidural analgesia is considered the standard of care but cannot be provided to all patients Liposomal bupivacaine has been approved for field blocks such as transversus abdominis plane (TAP) blocks but has not been clinically compared against other modalities. In this retrospective propensity matched cohort study we thus tested the primary hypothesis that TAP infiltration are noninferior (not worse) to continuous epidural analgesia and superior (better) to intravenous opioid analgesia in patients recovering from major lower abdominal surgery. 318 patients were propensity matched on 18 potential factors among three groups (106 per group): 1) TAP infiltration with bupivacaine liposome; 2) continuous Epidural analgesia with plain bupivacaine; and; 3) intravenous patient-controlled analgesia (IV PCA). We claimed TAP noninferior (not worse) over Epidural if TAP was noninferior (not worse) on total morphine-equivalent opioid and time-weighted average pain score (10-point scale) within first 72 hours after surgery with noninferiority deltas of 1 (10-point scale) for pain and an increase less of 20% in the mean morphine equivalent opioid consumption. We claimed TAP or Epidural groups superior (better) over IV PCA if TAP or Epidural was superior on opioid consumption and at least noninferior on pain outcome. Multivariable linear regressions within the propensity-matched cohorts were used to model total morphine-equivalent opioid dose and time-weighted average pain score within first 72 hours after surgery; joint hypothesis framework was used for formal testing. TAP infiltration were noninferior to Epidural on both primary outcomes (p<0.001). TAP infiltration were noninferior to IV PCA on pain scores (p = 0.001) but we did not find superiority on opioid consumption (p = 0.37). We did not find noninferiority of Epidural over IV PCA on pain scores (P = 0.13) and nor did we find superiority on opioid consumption (P = 0.98). TAP infiltration with liposomal bupivacaine and

  5. The influence of simulated transversus abdominis muscle force on sacroiliac joint flexibility during asymmetric moment application to the pelvis.

    PubMed

    Gnat, Rafael; Spoor, Kees; Pool-Goudzwaard, Annelies

    2015-10-01

    The role of so-called local muscle system in motor control of the lower back and pelvis is a subject of ongoing debate. Prevailing beliefs in stabilizing function of this system were recently challenged. This study investigated the impact of in vitro simulated force of transversely oriented fibres of the transversus abdominis muscle (a part of the local system) on flexibility of the sacroiliac joint during asymmetric moment application to the pelvis. In 8 embalmed specimens an incremental moment was applied in the sagittal plane to one innominate with respect to the fixed contralateral innominate. Ranges of motion of the sacroiliac joint were recorded using the Vicon Motion Capture System. Load-deformation curves were plotted and flexibility of the sacroiliac joint was calculated separately for anterior and posterior rotations of the innominate, with and without simulated muscle force. Flexibility of the sacroiliac joint was significantly bigger during anterior rotation of the innominate, as compared to posterior rotation (Anova P<0.05). After application of simulated force of transversus abdominis, flexibility of the joint did not change both during anterior and posterior rotations of the innominate. A lack of a stiffening effect of simulated transversus abdominis force on the sacroiliac joint was demonstrated. Earlier hypotheses suggesting a stiffening influence of this muscle on the pelvis cannot be confirmed. Consistent with previous findings smaller flexibility of the joint recorded during posterior rotation of the innominate may be of clinical importance for physio- and manual therapists. However, major limitations of the study should be acknowledged: in vitro conditions and simulation of only solitary muscle force. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. An anatomical study of the transversus abdominis plane block: location of the lumbar triangle of Petit and adjacent nerves.

    PubMed

    Jankovic, Zorica B; du Feu, Frances M; McConnell, Patricia

    2009-09-01

    The transversus abdominis plane (TAP) block is a new technique for providing analgesia to the anterior abdominal wall. Most previous studies have used the lumbar triangle of Petit as a landmark for the block. In this cadaveric study, we determined the exact position and size of the lumbar triangle of Petit and identified the nerves affected by the TAP block. The position of the lumbar triangle of Petit was assessed unilaterally in 26 cadaveric specimens relative to reliably palpable surface landmarks. In addition, a series of dissections were performed to explore the course of the nerves blocked by the TAP. The mean distance from the midaxillary line along the iliac crest to the center of the base of the lumbar triangle of Petit at the level of the subcutaneous tissue and over the skin surface was 6.9 cm (range, 4.5-9.2 cm) and 9.3 cm (range, 4-15.1 cm), respectively. The center of the lumbar triangle of Petit was 1.4 cm above the iliac crest. The depth of the TAP at the lumbar triangle of Petit position was 0.5-4 cm and at the midaxillary line it was 0.5-2 cm. The average size of the lumbar triangle of Petit was 2.3 cm x 3.3 cm x 2.2 cm, with an average area of 3.63 +/- 1.93 cm2. The three cadaveric specimens we explored showed the nerves blocked by TAP passed lateral to the triangle. An incidental finding was that in 66% of specimens the lumbar triangle of Petit contained small branches of the subcostal artery. The lumbar triangles of Petit found in the specimens in this study were more posterior than the literature suggests. The position of the lumbar triangle of Petit varies largely and the size is relatively small. The relevant nerves to be blocked had not entered the TAP in the specimens in this study at the point of the lumbar triangle of Petit. At the midaxillary line, however, all the nerves were in the TAP.

  7. A Spine Loading Model of Women in the Military

    DTIC Science & Technology

    1999-10-01

    Table 1.8. Left erector spinae anatomical cross-sectional areas ..................................... 42 Table 1.9. Right rectus abdominis anatomical...cross-sectional areas ................................ 43 Table 1.10. Left rectus abdominis anatomical cross-sectional areas...Right rectus abdominis coronal plane moment-arms ....................................... 59 Table 1.26. Left rectus abdominis coronal plane moment-arms

  8. Laparoscopic Harvest of the Rectus Abdominis for Perineal Reconstruction

    PubMed Central

    Agochukwu, Nneamaka; Bonaroti, Alisha; Beck, Sandra

    2017-01-01

    Summary: The rectus abdominis is a workhorse flap for perineal reconstruction, in particular after abdominoperineal resection (APR). Laparoscopic and robotic techniques for abdominoperineal surgery are becoming more common. The open harvest of the rectus abdominis negates the advantages of these minimally invasive approaches. (Sentence relating to advantages of laparoscopic rectus deleted here.) We present our early experience with laparoscopic harvest of the rectus muscle for perineal reconstruction. Three laparoscopic unilateral rectus abdominis muscle harvests were performed for perineal reconstruction following minimally invasive colorectal and urological procedures. The 2 patients who underwent APR also had planned external perineal skin reconstruction with local flaps. (Sentence deleted here to shorten abstract.) All rectus muscle harvests were performed laparoscopically. Two were for perineal reconstruction following laparoscopic APR, and 1 was for anterior vaginal wall reconstruction. This was done with 4 ports positioned on the contralateral abdomen. The average laparoscopic harvest time was 60–90 minutes. The rectus muscle remained viable in all cases. One patient developed partial necrosis of a posterior thigh fasciocutaneous flap after cancer recurrence. There were no pelvic abscesses, or abdominal wall hernias. Laparoscopic harvest of the rectus appears to be a cost-effective, reliable, and reproducible procedure for perineal with minimal donor-site morbidity. Larger clinical studies are needed to further establish the efficacy and advantages of the laparoscopic rectus for perineal reconstruction. PMID:29263976

  9. Large asymmetric hypertrophy of rectus abdominis muscle in professional tennis players.

    PubMed

    Sanchis-Moysi, Joaquin; Idoate, Fernando; Dorado, Cecilia; Alayón, Santiago; Calbet, Jose A L

    2010-12-31

    To determine the volume and degree of asymmetry of the musculus rectus abdominis (RA) in professional tennis players. The volume of the RA was determined using magnetic resonance imaging (MRI) in 8 professional male tennis players and 6 non-active male control subjects. Tennis players had 58% greater RA volume than controls (P = 0.01), due to hypertrophy of both the dominant (34% greater volume, P = 0.02) and non-dominant (82% greater volume, P = 0.01) sides, after accounting for age, the length of the RA muscle and body mass index (BMI) as covariates. In tennis players, there was a marked asymmetry in the development of the RA, which volume was 35% greater in the non-dominant compared to the dominant side (P<0.001). In contrast, no side-to-side difference in RA volume was observed in the controls (P = 0.75). The degree of side-to-side asymmetry increased linearly from the first lumbar disc to the pubic symphysis (r = 0.97, P<0.001). Professional tennis is associated with marked hypertrophy of the musculus rectus abdominis, which achieves a volume that is 58% greater than in non-active controls. Rectus abdominis hypertrophy is more marked in the non-dominant than in the dominant side, particularly in the more distal regions. Our study supports the concept that humans can differentially recruit both rectus abdominis but also the upper and lower regions of each muscle. It remains to be determined if this disequilibrium raises the risk of injury.

  10. The efficacy of oblique subcostal transversus abdominis plane block in laparoscopic cholecystectomy – a prospective, placebo controlled study

    PubMed Central

    Breazu, Caius Mihai; Ciobanu, Lidia; Hadade, Adina; Bartos, Adrian; Mitre, Călin; Mircea, Petru Adrian; Ionescu, Daniela

    2016-01-01

    Introduction Pain control after a laparoscopic cholecystectomy can represent a challenge, considering the side effects due to standard analgesia methods. Recently the transversus abdominis plane block (TAP Block) has been used as a part of multimodal analgesia with promising results. The subcostal approach (OSTAP Block), a variant on the TAP block, produces reliable unilateral supraumbilical analgesia. This study evaluated the efficacy of the OSTAP block with bupivacaine in laparoscopic cholecystectomy compared with the placebo OSTAP block. Material and Methods Sixty ASA I/II adult patients listed for elective laparoscopic cholecystectomy were randomly allocated in one of two groups: Group A (OSTAP placebo) received preoperatively bilateral OSTAP block with sterile normal saline and Group B (OSTAP bupivacaine) received bilateral preoperatively OSTAP block with the same volumes of 0.25% bupivacaine. Twenty-four hours postoperative opioid consumption, the dose of opioid required during surgery, opioid dose in the recovery unit (PACU) and PACU length of stay were evaluated. The quality of analgesia was assessed by the Visual Analogue Scale (VAS) at specific interval hours during 24 h, at rest and with movement. Results The mean intraoperative opioid consumption showed a significant difference between the two groups, (385 ± 72.52 mg in group A vs 173.67 ± 48.60 mg in group B, p < 0.001). The mean 24 h opioid consumption showed a statistically significant difference between groups (32 ± 26.05 mg vs 79 ± 16.68 mg, p < 0.001). PACU length of stay was significantly lower for group B patients compared with group A patients (20.67 ± 11.27 min vs 41.67 ± 12.41 min, p < 0.001). The OSTAP bupivacaine group had a statistically significant lower pain score than the OSTAP placebo group at 0, 2, 4, 6, 12, 24 h, both at rest and with movement. No signs or symptoms of local anaesthetic systemic toxicity or other complications were detected. Conclusion OSTAP block with

  11. Dexmedetomidine decreases the required amount of bupivacaine for ultrasound-guided transversus abdominis plane block in pediatrics patients: a randomized study.

    PubMed

    Raof, Rehab Abdel; El Metainy, Shahira Ahmed; Alia, Doaa Abou; Wahab, Moataza Abdel

    2017-02-01

    The effect of dexmedetomidine on the potency of bupivacaine for transversus abdominis plane (TAP) block in pediatric patients has not been investigated. The primary objective of this study was to assess the effectiveness of dexmedetomidine to decrease the concentration of bupivacaine needed for analgesia for ultrasound-guided TAP block in a pediatric patient undergoing hernia repair or hydrocelectomy. This is a randomized, double-blind, up-down, dose-finding study. Operating room. Sixty American Society of Anesthesiologists I and II patients aged 1-4 years scheduled for elective unilateral herniorrhaphy or hydrocelectomy. Patients were randomly assigned to 1 of the 2 groups: group B (0.125% bupivacaine, 1mL/kg) TAP block or group BD (0.125% bupivacaine plus 2μg/kg dexmedetomidine, 1mL/kg) TAP block. The response of each child was observed for 60 seconds after skin incision and evaluated as 'unsuccessful' when skin incision caused a change in hemodynamic parameters (heart rate and mean blood pressure) 20% more than the preincision values. If the response was determined to be unsuccessful, the concentration of bupivacaine administrated to the next patient was increased by 0.02%. If it was successful, the concentration of bupivacaine administrated to the next patient was decreased by 0.02%. The minimum local anesthetic concentration of bupivacaine was 0.0839% (0.0137) in the B group and 0.0550% (0.0169) in the BD group. The difference was statistically significant (t=7.165, P=.0001). The total postoperative analgesic dosage of morphine was significantly higher in the B group (0.17±0.04 mg/kg) than the BD group (0.11±0.02 mg/kg, P=.001). The addition of 2μg/kg of dexmedetomidine reduced the minimum local anesthetic concentration of bupivacaine used for a TAP block and improved postoperative analgesia in children undergoing surgery for inguinal hernia repair or hydrocelectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Effects of preoperative ultrasound-guided transversus abdominis plane block on pain after laparoscopic surgery for colorectal cancer: a double-blind randomized controlled trial.

    PubMed

    Oh, Tak Kyu; Yim, Jiyeon; Kim, Jaehyun; Eom, Woosik; Lee, Soon Ae; Park, Sung Chan; Oh, Jae Hwan; Park, Ji Won; Park, Boram; Kim, Dae Hyun

    2017-01-01

    Although laparoscopic colorectal surgery decreases postoperative pain and facilitates a speedier recovery compared with laparotomy, postoperative pain at trocar insertion sites remains a clinical concern. The objective of this study was to assess the effects of a preoperative ultrasound-guided transversus abdominis plane (TAP) block on pain after laparoscopic surgery for colorectal cancer. In total, 58 patients scheduled to undergo laparoscopic surgery following a diagnosis of colorectal cancer were included in this study. The patients were randomized into TAP and control groups; the TAP group patients received a preoperative ultrasound-guided bilateral TAP block with 0.5 mL/kg of 0.25 % bupivacaine, while the control patients received the block with an equal amount of saline. Pain on coughing and at rest was assessed during postanesthetic recovery (PAR; 1 h after surgery) and on postoperative days (PODs) 1 (24 h), 2 (48 h), and 3 (72 h) by an investigator blinded to group allocations using the numeric rating scale (NRS). The primary outcome was pain on coughing on postoperative day (POD) 1. Fifty-five patients were included in the final analysis, including 28 in the TAP and 27 in the control groups. The pain intensity on coughing and at rest during PAR and on PODs 1, 2, and 3 showed no significant differences between groups. Furthermore, there was no significant difference in postoperative opioid consumption, sedation scores, nausea scores at the four time points, complication rates, and length of hospital stay between groups. In colorectal cancer patients undergoing laparoscopic colorectal surgery, a TAP block did not offer enough benefit for clinical efficacy in terms of postoperative pain or analgesic consumption.

  13. Heuristic estimation of electromagnetically tracked catheter shape for image-guided vascular procedures

    NASA Astrophysics Data System (ADS)

    Mefleh, Fuad N.; Baker, G. Hamilton; Kwartowitz, David M.

    2014-03-01

    In our previous work we presented a novel image-guided surgery (IGS) system, Kit for Navigation by Image Focused Exploration (KNIFE).1,2 KNIFE has been demonstrated to be effective in guiding mock clinical procedures with the tip of an electromagnetically tracked catheter overlaid onto a pre-captured bi-plane fluoroscopic loop. Representation of the catheter in KNIFE differs greatly from what is captured by the fluoroscope, due to distortions and other properties of fluoroscopic images. When imaged by a fluoroscope, catheters can be visualized due to the inclusion of radiopaque materials (i.e. Bi, Ba, W) in the polymer blend.3 However, in KNIFE catheter location is determined using a single tracking seed located in the catheter tip that is represented as a single point overlaid on pre-captured fluoroscopic images. To bridge the gap in catheter representation between KNIFE and traditional methods we constructed a catheter with five tracking seeds positioned along the distal 70 mm of the catheter. We have currently investigated the use of four spline interpolation methods for estimation of true catheter shape and have assesed the error in their estimation of true catheter shape. In this work we present a method for the evaluation of interpolation algorithms with respect to catheter shape determination.

  14. Exercise and Transversus Abdominis Muscle Atrophy after 60-d Bed Rest.

    PubMed

    Belavý, Daniel Ludovic; Gast, Ulf; Felsenberg, Dieter

    2017-02-01

    This study aimed to investigate atrophy in the deep abdominal muscles, spinal extensors, and the effect of high-load resistive exercise with and without whole-body vibration after 60 d of strict bed rest. Twenty-four subjects underwent 60 d of head-down tilt bed rest and performed either resistive vibration exercise (RVE), resistive exercise only (RE), or no exercise control (2nd Berlin BedRest Study). The thickness of the transversus abdominis, internal oblique, and erector spinae muscles and the area of the multifidus muscle were measured bilaterally via real-time ultrasound. Intention-to-treat analysis was implemented, and P values were adjusted by the false discovery rate method. At the end of the bed rest, transversus abdominis thickness was reduced by 18.3% in the inactive group (P = 0.00011) with no significant change in the RVE (-4.0%; P = 0.014 vs control) or RE (-5.0%; P = 0.10 vs control) groups. In the inactive subjects, internal oblique thickness reduced by 10.6% (P = 0.0025) and by 7% (P > 0.05) in each of the training groups. The lengthening of the lumbar spine was greatest on day 1 (+7.4%, P = 0.004) and day 2 (+6.3%, P = 0.004; day 54: +4.1%, P = 0.023). A 4.7% reduction of multifidus area was observed on day 1 of bed rest (P = 0.0049) and a 4.2% reduction of erector spinae thickness was observed on day 2 (P = 0.0011). Extensor atrophy and spinal lengthening was not affected by exercise. No significant difference was seen between RVE and RE. Bed rest leads to atrophy of the transversus abdominis and internal oblique muscles. The exercise program, which implemented lower-limb and back extension exercises against shoulder restraints, was able to reduce atrophy seen in transversus abdominis in bed rest.

  15. Sexual dysfunction after colpectomy and vaginal reconstruction with a vertical rectus abdominis myocutaneous flap.

    PubMed

    Løve, Uffe S; Sjøgren, Pia; Rasmussen, Peter; Laurberg, Søren; Christensen, Henrik K

    2013-02-01

    The use of the vertical rectus abdominis myocutaneous flap in reconstruction after abdominoperineal resection or pelvic exenteration for neoplasia is well documented. However, functional outcomes after vaginal reconstruction, including sexual function, are poorly described. This study aimed to examine sexual function in women following extensive pelvic surgery with colpectomy and vaginal reconstruction with the use of a vertical rectus abdominis myocutaneous flap. This study is a retrospective review of medical records in combination with patient questionnaires. Nonresponders were followed up with a second contact. This study was performed at a tertiary care university medical center (Colorectal Section, Department of Surgery P, Aarhus University Hospital, Denmark) All women undergoing pelvic surgery and simultaneous vaginal reconstruction with the use of a vertical rectus abdominis myocutaneous flap between 2004 and 2010 at our department were identified from a patient database. Thirty women who were alive at the time of identification were included in the study. Sexual function before and after surgery was evaluated by the use of the Sexual function Vaginal changes Questionnaire. The main outcome end point was whether the patient was sexually active after vaginal reconstruction. Twenty-six participants (87%) answered the questionnaire. Fifty percent of patients reported an active sex life before surgery. In general, patients reported an unchanged desire for both physical and sexual contact after surgery. However, only 2 patients (14%) reported being sexually active after surgery. This was a retrospective study with a heterogeneous cohort involving several types of cancers and surgical procedures. Factors other than vertical rectus abdominis myocutaneous flap reconstruction itself may interfere with the sexual function. Extensive pelvic surgery with colpectomy leads to sexual dysfunction even when the vagina is reconstructed with a vertical rectus abdominis

  16. Ultrasound-guided transversus abdominis plane block in patients undergoing open inguinal hernia repair: 0.125% bupivacaine provides similar analgesic effect compared to 0.25% bupivacaine.

    PubMed

    Erdoğan Arı, Dilek; Yıldırım Ar, Arzu; Karadoğan, Firdevs; Özcabı, Yetkin; Koçoğlu, Ayşegül; Kılıç, Fatih; Akgün, Fatma Nur

    2016-02-01

    To evaluate the effectiveness of 0.125% bupivacaine compared to 0.25% bupivacaine for ultrasound-guided transversus abdominis plane (TAP) block in patients undergoing open inguinal hernia repair. Randomized, double-blind study. Educational and research hospital. Forty adult patients of American Society of Anesthesiologists physical status I-III undergoing elective primary unilateral open inguinal hernia repair under spinal anesthesia. Patients in group I received 20 mL of 0.25% bupivacaine, whereas patients in group II received 20 mL of 0.125% bupivacaine for TAP block at the end of the surgery. Pain intensity was assessed at rest and during coughing using 10-cm visual analog scale score at 5, 15, 30, and 45 minutes and 1, 2, 4, 6, 12, and 24 hours after TAP block. Morphine consumption and time to first morphine requirement were recorded. Visual analog scale scores at rest and during coughing were not significantly different between groups at all time points measured. Twenty-four hours of morphine consumption (7.72±7.33 mg in group I and 6.06±5.20 mg in group II; P=.437) and time to first morphine requirement (182.35±125.16 minutes in group I and 143.21±87.28 minutes in group II; P=.332) were not different between groups. 0.125% Bupivacaine provides similar analgesic effect compared to 0.25% bupivacaine for ultrasound-guided TAP block in patients undergoing open inguinal hernia repair. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Soccer Attenuates the Asymmetry of Rectus Abdominis Muscle Observed in Non-Athletes

    PubMed Central

    Idoate, Fernando; Calbet, Jose A. L.; Izquierdo, Mikel; Sanchis-Moysi, Joaquin

    2011-01-01

    Purpose To determine the volume and degree of asymmetry of the rectus abdominis muscle (RA) in professional soccer players. Methods The volume of the RA was determined using magnetic resonance imaging (MRI) in 15 professional male soccer players and 6 non-active male control subjects. Results Soccer players had 26% greater RA volume than controls (P<0.05), due to hypertrophy of both the dominant (28% greater volume, P<0.05) and non-dominant (25% greater volume, P<0.01) sides, after adjusting for age, length of the RA muscle and body mass index (BMI) as covariates. Total volume of the dominant side was similar to the contralateral in soccer players (P = 0.42) and in controls (P = 0.75) (Dominant/non-dominant = 0.99, in both groups). Segmental analysis showed a progressive increase in the degree of side-to-side asymmetry from the first lumbar disc to the pubic symphysis in soccer players (r = 0.80, P<0.05) and in controls (r = 0.75, P<0.05). The slope of the relationship was lower in soccer players, although this trend was not statistically significant (P = 0.14). Conclusions Professional soccer is associated with marked hypertrophy of the rectus abdominis muscle, which achieves a volume that is 26% greater than in non-active controls. Soccer induces the hypertrophy of the non-dominant side in proximal regions and the dominant side in regions closer to pubic symphysis, which attenuates the pattern of asymmetry of rectus abdominis observed in non-active population. It remains to be determined whether the hypertrophy of rectus abdominis in soccer players modifies the risk of injury. PMID:21541351

  18. Transversus Abdominis Plane Block Versus Wound Infiltration for Analgesia After Cesarean Delivery: A Randomized Controlled Trial.

    PubMed

    Tawfik, Mohamed Mohamed; Mohamed, Yaser Mohamed; Elbadrawi, Rania Elmohamadi; Abdelkhalek, Mostafa; Mogahed, Maiseloon Mostafa; Ezz, Hanaa Mohamed

    2017-04-01

    Transversus abdominis plane (TAP) block and local anesthetic wound infiltration provide analgesia after cesarean delivery. Studies comparing the 2 techniques are scarce, with conflicting results. This double-blind, randomized controlled trial aimed to compare bilateral ultrasound-guided TAP block with single-shot local anesthetic wound infiltration for analgesia after cesarean delivery performed under spinal anesthesia. We hypothesized that the TAP block would decrease postoperative cumulative fentanyl consumption at 24 hours. Eligible subjects were American Society of Anesthesiologists physical status II parturients with full-term singleton pregnancies undergoing elective cesarean delivery under spinal anesthesia. Exclusion criteria were: <19 years of age or >40 years of age; height <150 cm, weight <60 kg, body mass index ≥40 kg/m; contraindications to spinal anesthesia; history of recent opioid exposure; hypersensitivity to any of the drugs used in the study; significant cardiovascular, renal, or hepatic disease; and known fetal abnormalities. Eighty subjects were randomly allocated to 2 equal groups. In the infiltration group, participants received 15 mL of bupivacaine 0.25% in each side of the surgical wound (total 30 mL); and in the TAP group, participants received 20 mL of bupivacaine 0.25% bilaterally in the TAP block (total 40 mL). The TAP block and wound infiltration were performed by the primary investigator and the operating obstetrician, respectively. All participants received postoperative standard analgesia (ketorolac and paracetamol) and intravenous fentanyl via patient-controlled analgesia. Patients and outcome assessors were blinded to the study group. The primary outcome was the cumulative fentanyl consumption at 24 hours. Secondary outcomes were the time to the first postoperative fentanyl dose, cumulative fentanyl consumption at 2, 4, 6, and 12 hours, pain scores at rest and on movement at 2, 4, 6, 12, and 24 hours, the deepest level of

  19. Postoperative Analgesic Efficacy of Bilateral Transversus Abdominis Plane Block in Patients Undergoing Midline Colorectal Surgeries Using Ropivacaine: A Randomized, Double-blind, Placebo-controlled Trial.

    PubMed

    Qazi, Nahida; Bhat, Wasim Mohammad; Iqbal, Malik Zaffar; Wani, Anisur Rehman; Gurcoo, Showkat A; Rasool, Sahir

    2017-01-01

    Ultrasound-guided transversus abdominis plane (TAP) block is done as a part of multimodal analgesia for pain relief after abdominal surgeries. This prospective randomized, double-blind, placebo-controlled trial was conducted to evaluate the postoperative analgesic efficacy of bilateral TAP block in patients undergoing midline colorectal surgeries using ropivacaine. Eighty patients scheduled for elective colorectal surgeries involving midline abdominal wall incision under general anesthesia were enrolled in this prospective randomized controlled trial. Group A received TAP block with 20 ml of 0.2% ropivacaine on either side of the abdominal wall, and Group B received 20 ml of normal saline. The time to request for rescue analgesia, total analgesic consumption in 24 h, and satisfaction with the anesthetic technique were assessed. The mean visual analog scale scores at rest and on coughing were higher in control group ( P > 0.05). Time (min) to request for the first rescue analgesia was prolonged in study group compared to control group ( P < 0.001). The total tramadol consumption in 24 h postoperatively was significantly high in control group ( P < 0.001). Nausea/vomiting was more common in control group ( P > 0.05). The level of satisfaction concerning postoperative pain control/anesthetic technique was higher in study group ( P < 0.001). TAP block produces effective and prolonged postoperative analgesia in patients undergoing midline colorectal surgery. It is a technically simple block to perform with a high margin of safety. It produces a considerable reduction in mean intravenous postoperative tramadol requirements, reduction in postoperative pain scores, and increased time to first request for further analgesia, both at rest and on movement.

  20. Postoperative Analgesic Efficacy of Bilateral Transversus Abdominis Plane Block in Patients Undergoing Midline Colorectal Surgeries Using Ropivacaine: A Randomized, Double-blind, Placebo-controlled Trial

    PubMed Central

    Qazi, Nahida; Bhat, Wasim Mohammad; Iqbal, Malik Zaffar; Wani, Anisur Rehman; Gurcoo, Showkat A.; Rasool, Sahir

    2017-01-01

    Background: Ultrasound-guided transversus abdominis plane (TAP) block is done as a part of multimodal analgesia for pain relief after abdominal surgeries. This prospective randomized, double-blind, placebo-controlled trial was conducted to evaluate the postoperative analgesic efficacy of bilateral TAP block in patients undergoing midline colorectal surgeries using ropivacaine. Materials and Methods: Eighty patients scheduled for elective colorectal surgeries involving midline abdominal wall incision under general anesthesia were enrolled in this prospective randomized controlled trial. Group A received TAP block with 20 ml of 0.2% ropivacaine on either side of the abdominal wall, and Group B received 20 ml of normal saline. The time to request for rescue analgesia, total analgesic consumption in 24 h, and satisfaction with the anesthetic technique were assessed. Results: The mean visual analog scale scores at rest and on coughing were higher in control group (P > 0.05). Time (min) to request for the first rescue analgesia was prolonged in study group compared to control group (P < 0.001). The total tramadol consumption in 24 h postoperatively was significantly high in control group (P < 0.001). Nausea/vomiting was more common in control group (P > 0.05). The level of satisfaction concerning postoperative pain control/anesthetic technique was higher in study group (P < 0.001). Conclusion: TAP block produces effective and prolonged postoperative analgesia in patients undergoing midline colorectal surgery. It is a technically simple block to perform with a high margin of safety. It produces a considerable reduction in mean intravenous postoperative tramadol requirements, reduction in postoperative pain scores, and increased time to first request for further analgesia, both at rest and on movement. PMID:28928585

  1. Dynamic rectus abdominis muscle sphincter for stoma continence: an acute functional study in a dog model.

    PubMed

    Bardoel, J W; Stadelmann, W K; Perez-Abadia, G A; Galandiuk, S; Zonnevijlle, E D; Maldonado, C; Stremel, R W; Tobin, G R; Kon, M; Barker, J H

    2001-02-01

    Fecal stomal incontinence is a problem that continues to defy surgical treatment. Previous attempts to create continent stomas using dynamic myoplasty have had limited success due to denervation atrophy of the muscle flap used in the creation of the sphincter and because of muscle fatigue resulting from continuous electrical stimulation. To address the problem of denervation atrophy, a stomal sphincter was designed using the most caudal segment of the rectus abdominis muscle, preserving its intercostal innervation as well as its vascular supply. The purpose of the present study was to determine whether this rectus abdominis muscle island flap sphincter design could maintain stomal continence acutely. In this experiment, six dogs were used to create eight rectus abdominis island flap stoma sphincters around a segment of distal ileum. Initially, the intraluminal stomal pressures generated by the sphincter using different stimulation frequencies were determined. The ability of this stomal sphincter to generate continence at different intraluminal bowel pressures was then assessed. In all cases, the rectus abdominis muscle sphincter generated peak pressures well above those needed to maintain stomal continence (60 mmHg). In addition, each sphincter was able to maintain stomal continence at all intraluminal bowel pressures tested.

  2. Comparative analysis of the pressure profilometry of vesicocutaneous continent catheterizable conduits between patients with and without rectus abdominis neosphincter (Yachia principle).

    PubMed

    Rondon, Atila; Leslie, Bruno; Arcuri, Leonardo Javier; Ortiz, Valdemar; Macedo, Antonio

    2015-09-01

    To assess whether crossing rectus abdominis muscle strips, as proposed by Yachia, would change urinary catheterizable conduit's pressure profilometry, in static and dynamic conditions. Non-randomized selection of 20 continent patients that underwent Macedo's ileum-based reservoir, 10 including Yachia's technique (Study Group) and 10 without this mechanism of continence (Control Group). Demographics and cystometric data were assessed. Conduit's pressure profilometry was obtained by infusing saline through a multichannel catheter, at rest and during Valsalva maneuver. We assessed the pressure: (a) in the bladder; (b) in conduit's proximal segment; and (c) in conduit's distal segment, which is presumably the abdominal wall and crossed muscle strips site. Mean age at surgery was 6.1 years in the Control Group and 7.7 years in the Study Group. There was no statistically significant difference between groups regarding maximum cystometric bladder capacity and leakage point pressure. At rest, the pressure profilometry showed similar results between groups in all segments analyzed. During Valsalva maneuver, pressure profilometry showed similar results between groups in bladder and conduit's proximal segment pressure. In this condition, conduit's distal segment pressure in the Study Group (Mean = 72.9 and Peak = 128.7 cmH2 O) was significantly greater (P < 0.05) than conduit's distal segment pressure in the Control Group (Mean = 48.3 and Peak = 65.1 cmH2 O). Crossing muscle strips over the conduit significantly increases the pressure in its distal segment during contraction of the rectus abdominis muscle, which can be important in moments of sudden increase in abdominal pressure in order to keep continence. © 2014 Wiley Periodicals, Inc.

  3. Blunt transection of rectus abdominis following seatbelt related trauma with associated small and large bowel injury.

    PubMed

    Patel, K; Doolin, R; Suggett, N

    2013-01-01

    Closed rupture of rectus abdominis following seatbelt related trauma is rare. We present the case of a 45 year old female who presented with closed rupture of the rectus abdominis in conjunction with damage to small bowel mesentery and infarction of small and large bowel following a high velocity road traffic accident. Multiple intestinal resections were required resulting in short bowel syndrome and abdominal wall reconstruction with a porcine collagen mesh. Post-operative complications included intra-abdominal sepsis and an enterocutaneous fistula. The presence of rupture of rectus abdominis muscle secondary to seatbelt injury should raise the suspicion of intra-abdominal injury. Our case highlights the need for suspicion, investigation and subsequent surgical management of intra-abdominal injury following identification of this rare consequence of seatbelt trauma. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. A comparative study to evaluate ultrasound-guided transversus abdominis plane block versus ilioinguinal iliohypogastric nerve block for post-operative analgesia in adult patients undergoing inguinal hernia repair.

    PubMed

    Kamal, Kirti; Jain, Parul; Bansal, Teena; Ahlawat, Geeta

    2018-04-01

    Both transversus abdominis plane (TAP) block and combined ilioinguinal-iliohypogastric (IIN/IHN) blocks are used routinely under ultrasound (USG) guidance for postoperative pain relief in patients undergoing inguinal hernia surgery. This study compares USG guided TAP Vs IIN/IHN block for post-operative analgesic efficacy in adults undergoing inguinal hernia surgery. Sixty adults aged 18 to 60 with American Society of Anesthesiologsts' grade I or II were included. After general anaesthesia, patients in Group I received USG guided unilateral TAP block using 0.75% ropivacaine 3 mg/kg (maximum 25 mL) and those in Group II received IIN/IHN block using 10 mL 0.75% ropivacaine. Postoperative rescue analgesia was with tramadol (intravenous) IV ± diclofenac IV in the first 4 h followed by oral diclofenac subsequently. Total analgesic consumption in the first 24 h was the primary objective, intraoperative haemodynamics, number of attempts and time required for performing the block as well as the postoperative pain scores were also evaluated. Time to first analgesic request was 319.8 ± 115.2 min in Group I and 408 ± 116.4 min in Group II ( P = 0.005). Seven patients (23.33%) in Group I and two (6.67%) in Group II required tramadol in first four hours. No patient in either groups received diclofenac IV. The average dose of tablet diclofenac was 200 ± 35.96 mg in Group I and 172.5 ± 34.96 mg in Group II ( P = 0. 004). USG guided IIN/IHN block reduces the postoperative analgesic requirement compared to USG guided TAP block.

  5. Urinary catheters

    MedlinePlus

    ... drainage bag. The condom catheter must be changed every day. INTERMITTENT CATHETERS You would use an intermittent catheter ... and the catheter itself with soap and water every day. Also clean the area after every bowel movement ...

  6. Hydrophilic Catheters

    PubMed Central

    2006-01-01

    Executive Summary Objective To review the evidence on the effectiveness of hydrophilic catheters for patients requiring intermittent catheterization. Clinical Need There are various reasons why a person would require catheterization, including surgery, urinary retention due to enlargement of the prostate, spinal cord injuries, or other physical disabilities. Urethral catheters are the most prevalent cause of nosocomial urinary tract infections, that is, those that start or occur in a hospital. A urinary tract infection (UTI) occurs when bacteria adheres to the opening of the urethra. Most infections arise from Escherichia coli, from the colon. The bacteria spread into the bladder, resulting in the development of an infection. The prevalence of UTIs varies with age and sex. There is a tenfold increase in incidence for females compared with males in childhood and throughout adult life until around 55 years, when the incidence of UTIs in men and women is equal, mostly as a consequence of prostatic problems in men. Investigators have reported that urethritis (inflammation of the urethra) is found in 2% to 19% of patients practising intermittent catheterization. The Technology Hydrophilic catheters have a polymer coating that binds o the surface of the catheter. When the polymer coating is submersed in water, it absorbs and binds the water to the catheter. The catheter surface becomes smooth and very slippery. This slippery surface remains intact upon insertion into the urethra and maintains lubrication through the length of the urethra. The hydrophilic coating is designed to reduce the friction, as the catheter is inserted with the intention of reducing the risk of urethral damage. It has been suggested that because the hydrophilic catheters do not require manual lubrication they are more sterile and thus less likely to cause infection. Most hydrophilic catheters are prepackaged in sterile water, or there is a pouch of sterile water that is broken and released into the

  7. Cutaneous Sensory Block Area, Muscle-Relaxing Effect, and Block Duration of the Transversus Abdominis Plane Block: A Randomized, Blinded, and Placebo-Controlled Study in Healthy Volunteers.

    PubMed

    Støving, Kion; Rothe, Christian; Rosenstock, Charlotte V; Aasvang, Eske K; Lundstrøm, Lars H; Lange, Kai H W

    2015-01-01

    The transversus abdominis plane (TAP) block is a widely used nerve block. However, basic block characteristics are poorly described. The purpose of this study was to assess the cutaneous sensory block area, muscle-relaxing effect, and block duration. Sixteen healthy volunteers were randomized to receive an ultrasound-guided unilateral TAP block with 20 mL 7.5 mg/mL ropivacaine and placebo on the contralateral side. Measurements were performed at baseline and 90 minutes after performing the block. Cutaneous sensory block area was mapped and separated into a medial and lateral part by a vertical line through the anterior superior iliac spine. We measured muscle thickness of the 3 lateral abdominal muscle layers with ultrasound in the relaxed state and during maximal voluntary muscle contraction. The volunteers reported the duration of the sensory block and the abdominal muscle-relaxing effect. The lateral part of the cutaneous sensory block area was a median of 266 cm2 (interquartile range, 191-310 cm2) and the medial part 76 cm 2(interquartile range, 54-127 cm2). In all the volunteers, lateral wall muscle thickness decreased significantly by 9.2 mm (6.9-15.7 mm) during a maximal contraction. Sensory block and muscle-relaxing effect duration were 570 minutes (512-716 minutes) and 609 minutes (490-724 minutes), respectively. Cutaneous sensory block area of the TAP block is predominantly located lateral to a vertical line through the anterior superior iliac spine. The distribution is nondermatomal and does not cross the midline. The muscle-relaxing effect is significant and consistent. The block duration is approximately 10 hours with large variation.

  8. Analgesic efficacy of ultrasound guided transversus abdominis plane block versus local anesthetic infiltration in adult patients undergoing single incision laparoscopic cholecystectomy: A randomized controlled trial.

    PubMed

    Bava, Ejas P; Ramachandran, Rashmi; Rewari, Vimi; Chandralekha; Bansal, Virinder Kumar; Trikha, Anjan

    2016-01-01

    Transversus abdominis plane (TAP) block has been used to provide intra- and post-operative analgesia with single incision laparoscopic (SIL) bariatric and gynecological surgery with mixed results. Its efficacy in providing analgesia for SIL cholecystectomy (SILC) via the same approach remains unexplored. The primary objective of our study was to compare the efficacy of bilateral TAP block with local anesthetic infiltration for perioperative analgesia in patients undergoing SILC. This was a prospective, randomized, controlled, double-blinded trial performed in a tertiary care hospital. Forty-two patients undergoing SILC were randomized to receive either ultrasound-guided (USG) bilateral mid-axillary TAP blocks with 0.375% ropivacaine or local anesthetic infiltration of the port site. The primary outcome measure was the requirement of morphine in the first 24 h postoperatively. The data were analyzed using t -test, Mann-Whitney test or Chi-square test. The 24 h morphine requirement (mean ± standard deviation) was 34.57 ± 14.64 mg in TAP group and 32.76 ± 14.34 mg in local infiltration group ( P = 0.688). The number of patients requiring intraoperative supplemental fentanyl in TAP group was 8 and in local infiltration group was 16 ( P = 0.028). The visual analog scale scores at rest and on coughing were significantly higher in the local infiltration group in the immediate postoperative period ( P = 0.034 and P = 0.007, respectively). USG bilateral TAP blocks were not effective in decreasing 24 h morphine requirement as compared to local anesthetic infiltration in patients undergoing SILC although it provided some analgesic benefit intraoperatively and in the initial 4 h postoperatively. Hence, the benefits of TAP blocks are not worth the effort and time spent for administering them for this surgery.

  9. Analgesic efficacy of ultrasound guided transversus abdominis plane block versus local anesthetic infiltration in adult patients undergoing single incision laparoscopic cholecystectomy: A randomized controlled trial

    PubMed Central

    Bava, Ejas P.; Ramachandran, Rashmi; Rewari, Vimi; Chandralekha; Bansal, Virinder Kumar; Trikha, Anjan

    2016-01-01

    Background: Transversus abdominis plane (TAP) block has been used to provide intra- and post-operative analgesia with single incision laparoscopic (SIL) bariatric and gynecological surgery with mixed results. Its efficacy in providing analgesia for SIL cholecystectomy (SILC) via the same approach remains unexplored. Aims: The primary objective of our study was to compare the efficacy of bilateral TAP block with local anesthetic infiltration for perioperative analgesia in patients undergoing SILC. Settings and Design: This was a prospective, randomized, controlled, double-blinded trial performed in a tertiary care hospital. Materials and Methods: Forty-two patients undergoing SILC were randomized to receive either ultrasound-guided (USG) bilateral mid-axillary TAP blocks with 0.375% ropivacaine or local anesthetic infiltration of the port site. The primary outcome measure was the requirement of morphine in the first 24 h postoperatively. Statistical Analysis: The data were analyzed using t-test, Mann–Whitney test or Chi-square test. Results: The 24 h morphine requirement (mean ± standard deviation) was 34.57 ± 14.64 mg in TAP group and 32.76 ± 14.34 mg in local infiltration group (P = 0.688). The number of patients requiring intraoperative supplemental fentanyl in TAP group was 8 and in local infiltration group was 16 (P = 0.028). The visual analog scale scores at rest and on coughing were significantly higher in the local infiltration group in the immediate postoperative period (P = 0.034 and P = 0.007, respectively). Conclusion: USG bilateral TAP blocks were not effective in decreasing 24 h morphine requirement as compared to local anesthetic infiltration in patients undergoing SILC although it provided some analgesic benefit intraoperatively and in the initial 4 h postoperatively. Hence, the benefits of TAP blocks are not worth the effort and time spent for administering them for this surgery. PMID:27746552

  10. Transversus Abdominis Plane Block versus Ilioinguinal/Iliohypogastric Nerve Block with Wound Infiltration for Postoperative Analgesia in Inguinal Hernia Surgery: A Randomized Clinical Trial.

    PubMed

    Sujatha, Chinthavali; Zachariah, Mamie; Ranjan, R V; George, Sagiev Koshy; Ramachandran, T R; Pillai, Anil Radhakrishna

    2017-01-01

    Various analgesic modalities have been used for postoperative analgesia in patients undergoing inguinal hernia surgery. In this randomized clinical trial, we have compared the analgesic efficacy of transversus abdominis plane (TAP) block with that of ilioinguinal/iliohypogastric (IIIH) nerve block with wound infiltration in patients undergoing unilateral open inguinal hernia repair. The primary objective of this study was to compare the efficacy of postoperative analgesia of ultrasound-guided TAP block and IIIH block with wound infiltration (WI) in patients undergoing open inguinal hernia surgery. This was a randomized clinical trial performed in a tertiary care hospital. Sixty patients scheduled for hernia repair were randomized into two groups, Group T and Group I. Postoperatively, under ultrasound guidance, Group T received 20 ml of 0.25% ropivacaine - TAP block and Group I received 10 ml of 0.25% ropivacaine - IIIH block + WI with 10 ml of 0.25% ropivacaine. The primary outcome measure was the time to rescue analgesia in the first 24 h postoperatively. Fentanyl along with diclofenac was given as first rescue analgesic when the patient complained of pain. Statistical comparisons were performed using Student's t -test and Chi-square test. Mean time to rescue analgesia was 5.900 ± 1.881 h and 3.766 ± 1.754 h ( P < 0.001) and the mean pain scores were 5.73 ± 0.784 and 6.03 ± 0.850 for Group TAP and IIIH + WI, respectively. Hemodynamics were stable in both the groups. One-third of the patients received one dose of paracetamol in addition to the rescue analgesic in the first 24 h. There were no complications attributed to the block. As a multimodal analgesic regimen, definitely both TAP block and IIIH block with wound infiltration have a supporting role in providing analgesia in the postoperative period for adult inguinal hernia repair. In this study, ultrasound-guided TAP block provided longer pain control postoperatively than IIIH block with WI after inguinal

  11. Transversus abdominis plane block using a short-acting local anesthetic for postoperative pain after laparoscopic colorectal surgery: a systematic review and meta-analysis.

    PubMed

    Oh, Tak Kyu; Lee, Se-Jun; Do, Sang-Hwan; Song, In-Ae

    2018-02-01

    Transversus abdominis plane (TAP) block using a short-acting local anesthetic as part of multimodal analgesia is efficient in various abdominal surgeries, including laparoscopic surgery. However, information regarding its use in laparoscopic colorectal surgery is still limited and sometimes controversial. Therefore, we conducted a systematic review and meta-analysis to determine whether TAP block using a short-acting anesthetic has a positive postoperative analgesic outcome in patients who have undergone laparoscopic colorectal surgery. We searched for studies comparing the postoperative pain outcome after laparoscopic colorectal surgery between patients who received TAP block and a control group (placebo or no treatment). Outcome measures were early pain at rest (numeric rating scale [NRS] score at 0-2 h postoperatively), late pain at movement (NRS score at 24 h postoperatively), late pain at rest (NRS score at 24 h postoperatively), and postoperative opioid consumption (up to 24 h postoperatively). We used a random-effects model for the meta-analysis and Egger's regression test to detect publication bias. We included six studies involving 452 patients (224 in the TAP block group, 228 in the control group). Early and late pain scores at movement were significantly different between the TAP block and control groups (standardized mean difference: - 0.695, P < 0.0001 for early pain and - 0.242, P = 0.029 for late pain). There was no significant difference between the TAP block and control groups in early pain at rest (P = 0.475), late pain at rest (P = 0.826), and postoperative opioid consumption (P = 0.257). The TAP block using a short-acting anesthetic had a significant effect on the postoperative pain outcome in the early (0-2 h) and late (24 h) period at movement. However, it did not have a significant effect on the postoperative pain outcome in the early (0-2 h) and late (24 h) periods at rest after laparoscopic surgery.

  12. An Intelligent Catheter System Robotic Controlled Catheter System

    PubMed Central

    Negoro, M.; Tanimoto, M.; Arai, F.; Fukuda, T.; Fukasaku, K.; Takahashi, I.; Miyachi, S.

    2001-01-01

    Summary We have developed a novel catheter system, an intelligent catheter system, which is able to control a catheter by an externally-placed controller. This system has made from master-slave mechanism and has following three components; 1) a joy stick as a master (for operators) 2)a catheter controller as a slave (for a patient),3)a micro force sensor as a sensing device. This catheter tele-guiding system has abilities to perform intravascular procedures from the distant places. It may help to reduce the radiation exposures to the operators and also to help train young doctors. PMID:20663387

  13. Relative Efficacy of Ultrasound-guided Ilioinguinal-iliohypogastric Nerve Block versus Transverse Abdominis Plane Block for Postoperative Analgesia following Lower Segment Cesarean Section: A Prospective, Randomized Observer-blinded Trial.

    PubMed

    Kiran, L Vamsee; Sivashanmugam, T; Kumar, V R Hemanth; Krishnaveni, N; Parthasarathy, S

    2017-01-01

    Quality of postoperative analgesia after cesarean section makes difference to mother in child bonding, early ambulation, and discharge. Ilioinguinal iliohypogastric (ILIH) and transverse abdominis plane (TAP) block had been tried to reduce the opioid analgesics, but the relative efficacy is unknown. Hence, this study was designed to compare the efficacy of these two regional analgesic techniques in sparing postoperative rescue analgesic requirement following lower segment cesarean section (LSCS). Sixty patients who underwent LSCS were randomly allocated into two groups to receive either US-guided TAP block or ILIH nerve block using sealed envelope technique at the end of the surgery. In the postoperative ward, whenever patient complained of pain, pain nurse in-charge administered the rescue analgesics as per the study protocol. A blinded observer visited the patient at 0, 2, 4, 6, 8, 10, 12, and 24 h postoperative intervals and recorded the quality of pain relief and the amount of rescue analgesic consumed. All patients in both the study groups required one dose of rescue analgesics in the form of injection diclofenac sodium 50 mg intravenously but subsequently 57% of patients did not require any further analgesics till 24 h in the TAP block group whereas in ILIH group, only 13% did not require further analgesics ( P = 0.00), correspondingly the cumulative tramadol dose was significantly higher at all the time interval in the ILIH group when compared to the TAP group. Quality of postoperative analgesia provided by TAP block was superior to ILIH block following LSCS.

  14. [Post-operative pain after ultrasound transversus abdominis plane block versus trocar site infiltration in laparoscopic nephrectomy: a prospective study].

    PubMed

    Araújo, Ana M; Guimarães, Joana; Nunes, Catarina S; Couto, Paula S; Amadeu, Eduarda

    Transversus abdominis plane (TAP) block is useful in reducing post-operative pain in laparoscopic nephrectomy compared to placebo. The purpose of this work is to compare post-operative pain and recovery after TAP block or trocar site infiltration (TSI) in this surgery. A prospective, single blinded study on patients scheduled for laparoscopic nephrectomy. Patients were assigned to two groups: TSI Group: trocar site infiltration at the end of surgery; TAP Group: unilateral ultrasound-guided TAP block after induction. Sevoflurane and remifentanil, in a target controlled infusion mode, were used for maintenance of general anesthesia. Before the end of surgery paracetamol, tramadol and morphine were administered. Visual analogue scale (VAS 0-100mm) at rest and with cough was applied in three moments: in recovery room (T1 at admission and T2 before discharge) and 24h after surgery (T3). Pain scores with incentive spirometer were also evaluated at T3. In recovery, morphine was administered as a rescue drug whenever VAS>30mm. Time to oral intake, chair sitting, ambulation and length of hospital stay were evaluated 24h after surgery. Student's t-test and Chi-square test, and linear regression models. A p-value<0.05 was considered significant. Data are presented as mean (SD). Forty patients were enrolled in the study. The primary outcome variable, VAS pain scores did not show a statistical significant difference between groups (p>0.05). VAS at rest (TAP vs. TSI groups) was: T1=33±29 vs. 39±32, T2=10±9 vs. 17±18 and T3=7±12 vs. 10±18. VAS with cough (TAP vs. TSI groups) was: T1=51±34 vs. 45±32, T2=24±24 vs. 33±23 and T3=20±23 vs. 23±23. VAS with incentive spirometer (TAP vs. TSI groups) was: T3=21±27 vs. 21±25. Intraoperative remifentanil consumption was similar between TAP (0.16±0.07mcg.kg -1 .min -1 ) and TSI (0.18±0.9mcg.kg -1 .min -1 ) groups. There were no differences in opioid consumption between TAP (4.4±3.49mg) and TSI (6.87±4.83mg) groups during

  15. Catheter orifice configuration influences the effectiveness of continuous peripheral nerve blockade.

    PubMed

    Fredrickson, Michael J; Ball, Craig M; Dalgleish, Adam J

    2011-01-01

    We investigated perineural catheter threading distance and orifice configuration during continuous interscalene analgesia. One hundred fifty-three patients receiving an anterolateral interscalene catheter (catheter needle and nerve/plexus in a similar alignment) for elective shoulder surgery were randomized to 1 of 3 groups: following out-of-plane ultrasound confirmation of the needle tip immediately lateral to the C5/6 roots, a nonstimulating catheter was blindly advanced 0.5 cm (end-hole; n = 50), 2.5 cm (multiorifice; n = 50) or 5 cm (multiorifice; n = 53) beyond the needle tip. Ropivacaine 0.75% + lidocaine 1% (50:50) 20 mL was administered preoperatively via the catheter before surgery under general anesthesia. A ropivacaine 0.2% 2 mL/hr elastomeric infusion with mandatory 6 hourly (and on demand) 5-mL boluses was continued for more than 48 hrs with tramadol available as rescue. Patients were questioned in the recovery room, at 24 and 48 hrs for numerical rating pain score (0-10), ropivacaine bolus, and tramadol consumption. Patients were more frequently pain-free in the recovery room in the multiorifice 2.5 and 5 cm groups compared with the end-hole 0.5 cm group (94%, 91% vs 66%; P < 0.001). During the first 24 hrs, the end-hole group demonstrated an earlier time to first pain (median, 10 vs17, 15 hrs; P < 0.001), higher "average pain" (median, 3 vs 1, 2, P = 0.004), and more ropivacaine bolus (median, 5 vs 3, 3; P < 0.001) and tramadol consumption (P = 0.01). Groups 2.5 and 5 cm did not significantly differ in any outcomes. These results suggest that multiorifice catheters provide superior intermittent bolus continuous peripheral nerve blockade compared with end-hole catheters. For anterolateral approach interscalene catheter placement, there is minimal benefit, either way, to 2.5- or 5-cm blind catheter advancement.

  16. Effect of local wound infiltration and transversus abdominis plane block on morphine use after laparoscopic colectomy: a nonrandomized, single-blind prospective study.

    PubMed

    Park, Jun-Seok; Choi, Gyu-Seog; Kwak, Kyung-Hwa; Jung, Hoon; Jeon, Younghoon; Park, Sungsik; Yeo, Jinseok

    2015-05-01

    Recently, nonopioid-based treatment modalities have been used to improve analgesia and decrease opioid-related side effects after surgery. Transversus abdominis plane (TAP) block and local infiltration of the surgical wound are commonly used multimodal analgesia techniques after abdominal surgery; however, few studies have compared the effectiveness of a TAP block with that of local infiltration of surgical wounds in patients who have undergone laparoscopic colorectal surgery. Sixty patients undergoing laparoscopic colorectal surgery participated in this prospective comparative study. All patients were allocated to 1 of 2 groups as follows: the TAP group or the infiltration group. Patients in the TAP group received bilateral TAP blocks at the end of the surgery. Patients in the infiltration group received local infiltration of anesthetics in the surgical wounds after closure of the peritoneum. All patients received postoperative analgesia with morphine as a patient-controlled analgesia. Opioid consumption and pain scores were recorded at 2, 6, 24, and 48 h after the operation. The characteristics of patients in the TAP group (n = 30) and local infiltration group (n = 29) were comparable. Pain scores while coughing and at rest were not different between the two groups. Postoperative morphine use was significantly reduced in the TAP group compared with that in the local infiltration group at 2-6 h (2.9 ± 1.9 mg versus 4.5 ± 3.2 mg, P = 0.02), 6-24 h (5.5 ± 3.3 mg versus 10.2 ± 8.4 mg, P = 0.00), the first 24 h (16.6 ± 6.6 mg versus 24.0 ± 9.7 mg), and 48 h (23.6 ± 8.2 mg versus 31.8 ± 12.5 mg, P = 0.00). No differences in rescue analgesic use or side effects were noted between the groups. Compared with local anesthetic infiltration, bilateral TAP blocks decreased the cumulative morphine use at 24 h and 48 h postoperatively in patients who had undergone laparoscopic colorectal surgery. Copyright © 2015 Elsevier Inc

  17. Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.

    PubMed

    Knight, Bradley; Ayers, Gregory M; Cohen, Todd J

    2008-05-01

    Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial

  18. Avoiding Complications in Abdominal Wall Surgery: A Mathematical Model to Predict the Course of the Motor Innervation of the Rectus Abdominis.

    PubMed

    Tessone, Ariel; Nava, Maurizio; Blondeel, Phillip; Spano, Andrea

    2016-02-01

    Ever since its introduction, the transverse rectus abdominis myocutaneous flap has become the mainstay of autologous breast reconstruction. However, concerns regarding donor site morbidity due to the breach of abdominal wall musculature integrity soon followed. Muscle-sparing techniques, eventually eliminating the muscle from the flap all-together with the deep inferior epigastric artery perforator flap, did not eliminate the problem of abdominal wall weakness. This led to the conclusion that motor innervation might be at fault. Studies have shown that even in the presence of an intact rectus abdominis muscle, and an intact anterior rectus sheath, denervation of the rectus abdominis muscle results in significant abdominal wall weakness leading to superior and inferior abdominal bulges, and abdominal herniation. Our aim was to establish a mathematical model to predict the location of the motor innervation to the rectus abdominis muscle, and thus provide surgeons with a tool that will allow them to reduce abdominal morbidity during deep inferior epigastric artery perforator and free muscle-sparing transverse rectus abdominis myocutaneous surgery. We dissected 42 cadaveric hemiabdomens and mapped the course of the thoracolumbar nerves. We then standardized and analyzed our findings and presented them as a relative map which can be adjusted to body type and dimensions. Our dissections show that the motor innervation is closely related to the lateral vascular supply. Thus, when possible, we support the preferred utilization of the medial vascular supply, and the preservation of the lateral supply and motor innervation.

  19. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    PubMed

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  20. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections.

    PubMed

    Lorente, Leonardo

    2016-05-04

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it.

  1. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections

    PubMed Central

    Lorente, Leonardo

    2016-01-01

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it. PMID:27152256

  2. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    PubMed

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  3. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration

    PubMed Central

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-01-01

    Objective: Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. Methods: This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. Conclusion: The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance. PMID:25097505

  4. Ultrasound Assessment of the Transverse Abdominis During Functional Movement.

    PubMed

    Mangum, L Colby; Henderson, Kaitlin; Murray, Kyle P; Saliba, Susan A

    2018-05-01

    The traditional activation ratio divides contracted muscle thickness by resting muscle thickness while an abdominal draw-in maneuver is performed during hook lying. Ultrasound imaging during function, such as standing or gait, or peak knee flexion in a single-leg squat allows for further visualization of muscle activity. The goal of this study was to examine activation ratio calculations for transverse abdominis function in supine versus loaded conditions to determine the most informative normalization strategy for muscle activity based on thickness values. Transverse abdominis thickness was measured via ultrasound in 35 healthy participants under 4 different conditions. Comparisons were made between the traditional activation ratio tabletop, standing activation ratio (standing abdominal draw-in maneuver thickness/quiet standing thickness), and functional activation ratio (single-leg squat thickness/quiet standing thickness). Additionally, a cued activation ratio (single-leg squat with cued abdominal draw-in maneuver thickness/single-leg squat thickness) during the single-leg squat was obtained. Activation ratios of greater than 1.0 indicated that participants could activate the muscle during activity, and values were compared by analysis of variance. The participants included 23 women and 12 men with a mean age ± SD of 21.3 ± 2.7 years, mass of 66.1 ± 14.4 kg, and height of 168.5 ± 10.1 cm. Activation ratios exceeded 1.0 in 94.3% for the traditional activation ratio, 85.7% for the standing activation ratio, 82.9% for the cued activation ratio, and 82.9% for the functional activation ratio. With groups defined as tabletop activated or not, the standing, cued, and functional activation ratios were all significantly different (all P < .05). Normalizing muscle thickness to the corresponding functional position quiet value provides a useful functional activation ratio and may help clinicians better understand the transverse abdominis role

  5. Transversus Abdominis Plane Block Versus Caudal Epidural for Lower Abdominal Surgery in Children: A Double-Blinded Randomized Controlled Trial.

    PubMed

    Bryskin, Robert B; Londergan, Bevan; Wheatley, Rebekah; Heng, Renee; Lewis, Marjorie; Barraza, Mark; Mercer, Erica; Ye, Gang

    2015-08-01

    Transversus abdominis plane block (TAPB) has emerged as a safe and effective regional anesthesia technique for providing postoperative lower abdominal analgesia. Complications associated with TAPB are rare and pose a lower overall risk to the patient receiving a TAPB versus a caudal block, which is considered the gold standard for pediatric lower abdominal regional anesthesia. Our study hypothesis was that TAPB would initially be equivalent to caudal block in providing postoperative pain control but would also show improved pain relief beyond the anticipated caudal duration. This study was a double-blinded randomized controlled trial. Forty-five children between the ages of 1 and 9 undergoing bilateral ureteral reimplantation surgery through a low transverse incision were enrolled. Narcotic requirement, pain scores (FLACC/Wong-Baker FACES), episodes of emesis, and antispasmodic requirement were recorded in the postanesthesia care unit (PACU) and at 6-hour intervals for 24 hours from the time of block placement. Our protocol used a multimodal approach toward pain management in all children, including randomized regional technique, scheduled ketorolac, morphine as needed, and the antispasmodic, oxybutynin, as needed. Morphine requirement showed no statistical difference during the initial 12 hours (all P ≥ 0.68 at PACU, 6 and 12 hours). However, at 24 hours those patients randomized to receive the TAPB required less cumulative morphine than the caudal group (0.05 mg/kg ± 0.06 vs 0.09 mg/kg ± 0.07, P = 0.03). There was a trend toward fewer episodes of emesis in the TAPB group which reached statistical significance at 18 and 24 hours (6 vs 1 episodes, P = 0.03; and 9 vs 2 episodes, P = 0.02). Pain scores (0-10) were higher in the TAPB group in the PACU (3.46 ± 2.69 vs 1.71 ± 2.1, P = 0.02), but there were no significant differences at all subsequent time points (all P ≥ 0.10). The TAPB group also had a higher requirement for the bladder antispasmodic oxybutynin

  6. Effect of addition of dexamethasone to ropivacaine on post-operative analgesia in ultrasonography-guided transversus abdominis plane block for inguinal hernia repair: A prospective, double-blind, randomised controlled trial.

    PubMed

    Sharma, Uma Datt; Prateek; Tak, Himani

    2018-05-01

    Ultrasonography (USG)-guided transversus abdominis plane (TAP) block is an abdominal field block with high efficacy. This study was undertaken with the aim of determining the effect of the addition of dexamethasone to 0.5% ropivacaine on post-operative analgesia in USG-guided TAP block for inguinal hernia repair. A double-blind randomised control study was conducted on sixty patients posted for inguinal hernia repair with the American Society of Anesthesiologists physical Status I or II, who were allocated two groups of 30 each. Patients in Group RS received 0.5% ropivacaine (20 ml) and normal saline (2 ml) whereas patients in Group RD received 0.5% ropivacaine (20 ml) and dexamethasone (2 ml, i.e., 8 mg), in USG-guided TAP Block on the same side, after repair of inguinal hernia under spinal anaesthesia. Visual analogue scale (VAS) scores, time for request of first analgesia and total tramadol consumption in first 24 h were compared. Unpaired Student's t -test and Mann-Whitney U-test were performed using SPSS 23 Software. Patients in Group RD had significantly lower VAS scores as compared to Group RS from 4 th to 12 th h, postoperatively. Duration of analgesia was significantly more in Group RD (547.50 [530,530] min) when compared with Group RS (387.50 [370,400] min) ( P < 0.001). The demand for intravenous tramadol was significantly low in Group RD (223.33 ± 56.83 mg) as compared to Group RS (293.33 ± 25.71 mg) ( P < 0.001). Addition of dexamethasone to ropivacaine in USG-guided TAP block significantly reduces post-operative pain and prolongs the duration of post-operative analgesia, thereby reducing analgesic consumption.

  7. Rectus abdominis muscle injuries in elite handball players: management and rehabilitation

    PubMed Central

    Balius, Ramon; Pedret, Carles; Pacheco, Laura; Gutierrez, Josep Antoni; Vives, Joan; Escoda, Jaume

    2011-01-01

    Muscle injuries generally occur in two-joint muscles with a high percentage of type II fibers during the performance of eccentric activity. Some muscle injuries, such as those located in the adductor longus, a monoarticular muscle, as well as rectus abdominis do not fully comply with these requirements. This study examines five cases of elite handball players with ruptured rectus abdominals. Sonographically, lesions in rectus abdominis are shown as a disruption of the fibrillar pattern with a hematic suffusion that invades the entire lesion. In some of the cases, the ultrasound study was complemented with a MRI. A unified rehabilitation protocol was applied and the return to play time of each handball player ranged between 16 and 22 days, with an average of 18.2 days. Follow-up at 15 months showed no evidence of re-injury or residual discomfort and all of them are playing at their highest level. The aim of this study was to illustrate a feature of handball injury that, as in tennis and volleyball, is uncommon and so far has not been specifically reported. The phenomenon of contralateral abdominal hypertrophy in handball appears in the dominant arm as in tennis and volleyball. PMID:24198573

  8. Effect of transversus abdominis plane block in combination with general anesthesia on perioperative opioid consumption, hemodynamics, and recovery in living liver donors: The prospective, double-blinded, randomized study.

    PubMed

    Erdogan, Mehmet A; Ozgul, Ulku; Uçar, Muharrem; Yalin, Mehmet R; Colak, Yusuf Z; Çolak, Cemil; Toprak, Huseyin I

    2017-04-01

    Transversus abdominis plane (TAP) block provides effective postoperative analgesia after abdominal surgeries. It can be also a useful strategy to reduce perioperative opioid consumption, support intraoperative hemodynamic stability, and promote early recovery from anesthesia. The aim of this prospective randomized double-blind study was to assess the effect of subcostal TAP blocks on perioperative opioid consumption, hemodynamic, and recovery time in living liver donors. The prospective, double-blinded, randomized controlled study was conducted with 49 living liver donors, aged 18-65 years, who were scheduled to undergo right hepatectomy. Patients who received subcostal TAP block in combination with general anesthesia were allocated into Group 1, and patients who received general anesthesia alone were allocated into Group 2. The TAP blocks were performed bilaterally by obtaining an image with real-time ultrasound guidance using 0.5% bupivacaine diluted with saline to reach a total volume of 40 mL. The primary outcome measure in our study was perioperative remifentanil consumption. Secondary outcomes were mean blood pressure (MBP), heart rate (HR), mean desflurane requirement, anesthesia recovery time, frequency of emergency vasopressor use, total morphine use, and length of hospital stay. Total remifentanil consumption and the anesthesia recovery time were significantly lower in Group 1 compared with Group 2. Postoperative total morphine use and length of hospital stay were also reduced. Changes in the MAP and HR were similar in the both groups. There were no significant differences in HR and MBP between groups at any time. Combining subcostal TAP blocks with general anesthesia significantly reduced perioperative and postoperative opioid consumption, provided shorter anesthesia recovery time, and length of hospital stay in living liver donors. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Hemodialysis Tunneled Catheter Noninfectious Complications

    PubMed Central

    Miller, Lisa M.; MacRae, Jennifer M.; Kiaii, Mercedeh; Clark, Edward; Dipchand, Christine; Kappel, Joanne; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; Pike, Pamela; Hiremath, Swapnil

    2016-01-01

    Noninfectious hemodialysis catheter complications include catheter dysfunction, catheter-related thrombus, and central vein stenosis. The definitions, causes, and treatment strategies for catheter dysfunction are reviewed below. Catheter-related thrombus is a less common but serious complication of catheters, requiring catheter removal and systemic anticoagulation. In addition, the risk factors, clinical manifestation, and treatment options for central vein stenosis are outlined. PMID:28270922

  10. Tissue elasticity of in vivo skeletal muscles measured in the transverse and longitudinal planes using shear wave elastography.

    PubMed

    Chino, Kentaro; Kawakami, Yasuo; Takahashi, Hideyuki

    2017-07-01

    The aim of the present study was to measure in vivo skeletal muscle elasticity in the transverse and longitudinal planes using shear wave elastography and then to compare the image stability, measurement values and measurement repeatability between these imaging planes. Thirty-one healthy males participated in this study. Tissue elasticity (shear wave velocity) of the medial gastrocnemius, rectus femoris, biceps brachii and rectus abdominis was measured in both the transverse and longitudinal planes using shear wave elastography. Image stability was evaluated by the standard deviation of the colour distribution in the shear wave elastography image. Measurement repeatability was assessed by the coefficient of variance obtained from three measurement values. Image stability of all tested muscles was significantly higher in the longitudinal plane (P<0·001), but measurement repeatability did not differ significantly between the imaging planes (P>0·05), except in the biceps brachii (P = 0·001). Measurement values of the medial gastrocnemius, rectus femoris and biceps brachii were significantly different between the imaging planes (P<0·001). Image stability and measurement values of shear wave elastography images varied with imaging plane, which indicates that imaging plane should be considered when measuring skeletal muscle tissue elasticity by shear wave elastography. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  11. Peritoneal Dialysis Catheter Insertion.

    PubMed

    Crabtree, John H; Chow, Kai-Ming

    2017-01-01

    The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Normal postural responses preceding shoulder flexion: co-activation or asymmetric activation of transverse abdominis?

    PubMed

    Davarian, Sanaz; Maroufi, Nader; Ebrahimi, Esmaeil; Parnianpour, Mohammad; Farahmand, Farzam

    2014-01-01

    It is suggested that activation of the transverse abdominis muscle has a stabilizing effect on the lumbar spine by raising intra-abdominal pressure without added disc compression. However, its feedforward activity has remained a controversial issue. In addition, research regarding bilateral activation of trunk muscles during a unilateral arm movement is limited. The aim of this study was to evaluate bilateral anticipatory activity of trunk muscles during unilateral arm flexion. Eighteen healthy subjects (aged 25 ± 3.96 years) participated in this study and performed 10 trials of rapid arm flexion in response to a visual stimulus. The electromyographic activity of the right anterior deltoid (AD) and bilateral trunk muscles including the transverse abdominis/internal oblique (TA/IO), superficial lumbar multifidus (SLM) and lumbar erector spine (LES) was recorded. The onset latency and anticipatory activity of the recorded trunk muscles were calculated. The first muscle activated in anticipation of the right arm flexion was the left TA/IO. The right TA/IO activated significantly later than all other trunk muscles (P < 0.0005). In addition, anticipatory activity of the right TA/IO was significantly lower than all other trunk muscles (P < 0.0005). There was no significant difference in either onset latency or anticipatory activity among other trunk muscles (P > 0.05). Healthy subjects showed no bilateral anticipatory co-activation of TA/IO in unilateral arm elevation. Further investigations are required to delineate normal muscle activation pattern in healthy subjects prior to prescribing bilateral activation training of transverse abdominis for subjects with chronic low back pain.

  13. Use of the rectus abdominis muscle for abdominal stoma sphincter construction: an anatomical feasibility study.

    PubMed

    Bardoel, J W; Stadelmann, W K; Tobin, G R; Werker, P M; Stremel, R W; Kon, M; Barker, J H

    2000-02-01

    Permanent fecal abdominal stomas significantly decrease quality of life. Previous attempts to create continent stomas by using dynamic myoplasty procedures have resulted in disappointing outcomes, primarily owing to denervation atrophy of the muscle flap that was used in the creation of the sphincter and because of muscle fatigue resulting from continuous electrical stimulation that is received by the flap to force contraction. On the basis of these problems, we designed two separate studies: an anatomical study addressing flap denervation and a functional study addressing muscle fatigue. The present study addresses the first topic and was designed to develop a rectus abdominis muscle flap into a sphincter that was anatomically situated to create a stoma while preserving as much innervation as possible. In 24 rectus abdominis muscles of human cadavers, the neurovascular anatomy was defined, then the anatomical feasibility of two different muscle flap configurations was considered. The flaps investigated were the peninsula flap and island flap designs, with both using the most caudal segment of the rectus abdominis muscle in construction of the sphincter. Neither flap design required the killing of a nerve for stoma sphincter creation, resulting in minimal muscle denervation. The conclusion of our comparison was that the above, in conjunction with other features of the island flap design, such as muscle overlap after sphincter formation and abdominal wall positioning of the sphincter, made the island flap design better suited to stoma sphincter construction.

  14. Compensation for Unconstrained Catheter Shaft Motion in Cardiac Catheters

    PubMed Central

    Degirmenci, Alperen; Loschak, Paul M.; Tschabrunn, Cory M.; Anter, Elad; Howe, Robert D.

    2016-01-01

    Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures. PMID:27525170

  15. Catheter-related bloodstream infection.

    PubMed

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  16. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    PubMed

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  17. SU-E-T-362: Automatic Catheter Reconstruction of Flap Applicators in HDR Surface Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buzurovic, I; Devlin, P; Hansen, J

    2014-06-01

    Purpose: Catheter reconstruction is crucial for the accurate delivery of radiation dose in HDR brachytherapy. The process becomes complicated and time-consuming for large superficial clinical targets with a complex topology. A novel method for the automatic catheter reconstruction of flap applicators is proposed in this study. Methods: We have developed a program package capable of image manipulation, using C++class libraries of The-Visualization-Toolkit(VTK) software system. The workflow for automatic catheter reconstruction is: a)an anchor point is placed in 3D or in the axial view of the first slice at the tip of the first, last and middle points for the curvedmore » surface; b)similar points are placed on the last slice of the image set; c)the surface detection algorithm automatically registers the points to the images and applies the surface reconstruction filter; d)then a structured grid surface is generated through the center of the treatment catheters placed at a distance of 5mm from the patient's skin. As a result, a mesh-style plane is generated with the reconstructed catheters placed 10mm apart. To demonstrate automatic catheter reconstruction, we used CT images of patients diagnosed with cutaneous T-cell-lymphoma and imaged with Freiburg-Flap-Applicators (Nucletron™-Elekta, Netherlands). The coordinates for each catheter were generated and compared to the control points selected during the manual reconstruction for 16catheters and 368control point Results: The variation of the catheter tip positions between the automatically and manually reconstructed catheters was 0.17mm(SD=0.23mm). The position difference between the manually selected catheter control points and the corresponding points obtained automatically was 0.17mm in the x-direction (SD=0.23mm), 0.13mm in the y-direction (SD=0.22mm), and 0.14mm in the z-direction (SD=0.24mm). Conclusion: This study shows the feasibility of the automatic catheter reconstruction of flap applicators with a high

  18. Catheter associated urinary tract infections

    PubMed Central

    2014-01-01

    Urinary tract infection attributed to the use of an indwelling urinary catheter is one of the most common infections acquired by patients in health care facilities. As biofilm ultimately develops on all of these devices, the major determinant for development of bacteriuria is duration of catheterization. While the proportion of bacteriuric subjects who develop symptomatic infection is low, the high frequency of use of indwelling urinary catheters means there is a substantial burden attributable to these infections. Catheter-acquired urinary infection is the source for about 20% of episodes of health-care acquired bacteremia in acute care facilities, and over 50% in long term care facilities. The most important interventions to prevent bacteriuria and infection are to limit indwelling catheter use and, when catheter use is necessary, to discontinue the catheter as soon as clinically feasible. Infection control programs in health care facilities must implement and monitor strategies to limit catheter-acquired urinary infection, including surveillance of catheter use, appropriateness of catheter indications, and complications. Ultimately, prevention of these infections will require technical advances in catheter materials which prevent biofilm formation. PMID:25075308

  19. Use of peripherally inserted central catheters as an alternative to central catheters in neurocritical care units.

    PubMed

    DeLemos, Christi; Abi-Nader, Judy; Akins, Paul T

    2011-04-01

    Patients in neurological critical care units often have lengthy stays that require extended vascular access and invasive hemodynamic monitoring. The traditional approach for these patients has relied heavily on central venous and pulmonary artery catheters. The aim of this study was to evaluate peripherally inserted central catheters as an alternative to central venous catheters in neurocritical care settings. Data on 35 patients who had peripherally inserted central catheters rather than central venous or pulmonary artery catheters for intravascular access and monitoring were collected from a prospective registry of neurological critical care admissions. These data were cross-referenced with information from hospital-based data registries for peripherally inserted central catheters and subarachnoid hemorrhage. Complete data were available on 33 patients with Hunt-Hess grade IV-V aneurysmal subarachnoid hemorrhage. Catheters remained in place a total of 649 days (mean, 19 days; range, 4-64 days). One patient (3%) had deep vein thrombosis in an upper extremity. In 2 patients, central venous pressure measured with a peripherally inserted catheter was higher than pressure measured concurrently with a central venous catheter. None of the 33 patients had a central catheter bloodstream infection or persistent insertion-related complications. CONCLUSIONS Use of peripherally inserted central catheters rather than central venous catheters or pulmonary artery catheters in the neurocritical care unit reduced procedural and infection risk without compromising patient management.

  20. PRE-INOCULATION OF URINARY CATHETERS WITH ESCHERICHIA COLI 83972 INHIBITS CATHETER COLONIZATION BY ENTEROCOCCUS FAECALIS

    PubMed Central

    TRAUTNER, BARBARA W.; DAROUICHE, RABIH O.; HULL, RICHARD A.; HULL, SHEILA; THORNBY, JOHN I.

    2010-01-01

    Purpose The capacity of a preexisting coating of Escherichia coli 83972 to reduce catheter colonization by Enterococcus faecalis 210 was investigated. Enterococcus was chosen for these trials since it is a common urinary pathogen in patients with an indwelling urinary catheter. Materials and Methods Each experiment tested 3 growth conditions. Group 1 or E. coli plus Enterococcus catheters were exposed to E. coli 83972 for 24 hours and then to Enterococcus for 30 minutes. Group 2 or E. coli alone catheters were incubated in E. coli for 24 hours and then in sterile broth for 30 minutes. Group 3 or Enterococcus alone catheters did not undergo the initial incubation with E. coli before the 30-minute incubation with Enterococcus: All catheters were then incubated in sterile human urine for 24 hours. Catheters were washed with saline and cut into 5, 1 cm. segments. Each segment was sonicated and the sonication fluid was diluted and plated. The results of each of the 5 segments were averaged and the set of experiments was repeated 7 times. Results A preexisting coating of E. coli 83972 reduced catheter colonization by E. faecalis 210 more than 10-fold. Enterococcus alone catheters had a median of 9.7 × 105 enterococci per cm., whereas E. coli plus Enterococcus catheters had a median of 0.38 × 105 enterococci per cm. (p = 0.016). Conclusions Pre-inoculating urinary catheters with E. coli 83972 significantly impedes catheter colonization by Enterococcus: These promising in vitro results prompt the clinical investigation of this particular application of bacterial interference. PMID:11743359

  1. Role of ultrasound guided transversus abdominis plane block as a component of multimodal analgesic regimen for lower segment caesarean section: a randomized double blind clinical study.

    PubMed

    Jadon, Ashok; Jain, Priyanka; Chakraborty, Swastika; Motaka, Mayur; Parida, Sudhansu Sekhar; Sinha, Neelam; Agrawal, Amit; Pati, Asit Kumar

    2018-05-14

    While opioids are the mainstay for post-operative analgesia after lower segment caesarean section, they are associated with various untoward effects. Ultrasound guided transversus abdominis plane (TAP) block has been postulated to provide effective analgesia for caesarean section. We evaluated the analgesic efficacy of this block for post caesarean analgesia in a randomised controlled trial. One hundred thirty-nine mothers undergoing caesarean delivery were randomised to receive TAP block with either 20 ml 0.375% ropivacaine or 20 ml saline after obtaining informed consent. All the subjects received a standard spinal anaesthetic and diclofenac was administered for post-operative pain. Breakthrough pain was treated with tramadol. Post-operatively, all the subjects were assessed at 0, 2, 4, 6, 8, 10, 12, 18 & 24 h. The primary outcome was the time to first analgesic request. The secondary measures of outcome were pain, nausea, sedation, number of doses of tramadol administered and satisfaction with the pain management. The median (interquartile range) time to first analgesic request was prolonged in the TAP group compared to the control group (p < 0.0001); 11 h (8,12) and 4 h (2.5,6) respectively. The median (interquartile range) number of doses of tramadol consumed in the TAP group was 0 (0,1) compared to 2 (1,2) in the control group (p < 0.0001). At all points in the study, pain scores both at rest and on movement were lower in the study group (p < 0.0001). Maternal satisfaction with pain relief was also higher in the study group (p 0.0002). One subject in the TAP group had convulsions following injection of local anaesthetic solution. She was managed conservatively with supportive treatment following which she recovered. TAP block reduces pain, prolongs the duration of analgesia and decreases supplemental opioid consumption when used for multimodal analgesia for pain relief after caesarean section. However, the risk of local anaesthetic systemic

  2. A statistical model of catheter motion from interventional x-ray images: application to image-based gating

    NASA Astrophysics Data System (ADS)

    Panayiotou, M.; King, A. P.; Ma, Y.; Housden, R. J.; Rinaldi, C. A.; Gill, J.; Cooklin, M.; O'Neill, M.; Rhode, K. S.

    2013-11-01

    The motion and deformation of catheters that lie inside cardiac structures can provide valuable information about the motion of the heart. In this paper we describe the formation of a novel statistical model of the motion of a coronary sinus (CS) catheter based on principal component analysis of tracked electrode locations from standard mono-plane x-ray fluoroscopy images. We demonstrate the application of our model for the purposes of retrospective cardiac and respiratory gating of x-ray fluoroscopy images in normal dose x-ray fluoroscopy images, and demonstrate how a modification of the technique allows application to very low dose scenarios. We validated our method on ten mono-plane imaging sequences comprising a total of 610 frames from ten different patients undergoing radiofrequency ablation for the treatment of atrial fibrillation. For normal dose images we established systole, end-inspiration and end-expiration gating with success rates of 100%, 92.1% and 86.9%, respectively. For very low dose applications, the method was tested on the same ten mono-plane x-ray fluoroscopy sequences without noise and with added noise at signal to noise ratio (SNR) values of √50, √10, √8, √6, √5, √2 and √1 to simulate the image quality of increasingly lower dose x-ray images. The method was able to detect the CS catheter even in the lowest SNR images with median errors not exceeding 2.6 mm per electrode. Furthermore, gating success rates of 100%, 71.4% and 85.7% were achieved at the low SNR value of √2, representing a dose reduction of more than 25 times. Thus, the technique has the potential to extract useful information whilst substantially reducing the radiation exposure.

  3. Surface electromyography activity of the rectus abdominis, internal oblique, and external oblique muscles during forced expiration in healthy adults.

    PubMed

    Ito, Kenichi; Nonaka, Koji; Ogaya, Shinya; Ogi, Atsushi; Matsunaka, Chiaki; Horie, Jun

    2016-06-01

    We aimed to characterize rectus abdominis, internal oblique, and external oblique muscle activity in healthy adults under expiratory resistance using surface electromyography. We randomly assigned 42 healthy adult subjects to 3 groups: 30%, 20%, and 10% maximal expiratory intraoral pressure (PEmax). After measuring 100% PEmax and muscle activity during 100% PEmax, the activity and maximum voluntary contraction of each muscle during the assigned experimental condition were measured. At 100% PEmax, the external oblique (p<0.01) and internal oblique (p<0.01) showed significantly elevated activity compared with the rectus abdominis muscle. Furthermore, at 20% and 30% PEmax, the external oblique (p<0.05 and<0.01, respectively) and the internal oblique (p<0.05 and<0.01, respectively) showed significantly elevated activity compared with the rectus abdominis muscle. At 10% PEmax, no significant differences were observed in muscle activity. Although we observed no significant difference between 10% and 20% PEmax, activity during 30% PEmax was significantly greater than during 20% PEmax (external oblique: p<0.05; internal oblique: p<0.01). The abdominal oblique muscles are the most active during forced expiration. Moreover, 30% PEmax is the minimum intensity required to achieve significant, albeit very slight, muscle activity during expiratory resistance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Reconstruction of Abdominal Wall of a Chronically Infected Postoperative Wound with a Rectus Abdominis Myofascial Splitting Flap

    PubMed Central

    Bae, Sung Kyu; Kang, Seok Joo; Kim, Jin Woo; Kim, Young Hwan

    2013-01-01

    Background If a chronically infected abdominal wound develops, complications such as peritonitis and an abdominal wall defect could occur. This could prolong the patient's hospital stay and increase the possibility of re-operation or another infection as well. For this reason, a solution for infection control is necessary. In this study, surgery using a rectus abdominis muscle myofascial splitting flap was performed on an abdominal wall defect. Methods From 2009 to 2012, 5 patients who underwent surgery due to ovarian rupture, cesarean section, or uterine myoma were chosen. In each case, during the first week after operation, the wound showed signs of infection. Surgery was chosen because the wounds did not resolve with dressing. Debridement was performed along the previous operation wound and dissection of the skin was performed to separate the skin and subcutaneous tissue from the attenuated rectus muscle and Scarpa's fascial layers. Once the anterior rectus sheath and muscle were adequately mobilized, the fascia and muscle flap were advanced medially so that the skin defect could be covered for reconstruction. Results Upon 3-week follow-up after a rectus abdominis myofascial splitting flap operation, no major complication occurred. In addition, all of the patients showed satisfaction in terms of function and esthetics at 3 to 6 months post-surgery. Conclusions Using a rectus abdominis myofascial splitting flap has many esthetic and functional benefits over previous methods of abdominal defect treatment, and notably, it enabled infection control by reconstruction using muscle. PMID:23362477

  5. Indwelling catheter care

    MedlinePlus

    ... it overnight. You will be shown how to disconnect the bags from the Foley catheter in order ... bags through a separate valve without needing to disconnect the bag from the Foley catheter. Making Sure ...

  6. Determining the best catheter for sonohysterography.

    PubMed

    Dessole, S; Farina, M; Capobianco, G; Nardelli, G B; Ambrosini, G; Meloni, G B

    2001-09-01

    To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost. Prospective study. University hospital. Six hundred ten women undergoing SHG. We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN). We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters. In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive. The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.

  7. Evaluation of three-dimensional printing for internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach: a preliminary report.

    PubMed

    Zeng, Canjun; Xiao, Jidong; Wu, Zhanglin; Huang, Wenhua

    2015-01-01

    The aim of this study is to evaluate the efficacy and feasibility of three-dimensional printing (3D printing) assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach. A total of 38 patients with unstable pelvic fractures were analyzed retrospectively from August 2012 to February 2014. All cases were treated operatively with internal fixation assisted by three-dimensional printing from minimal invasive para-rectus abdominis approach. Both preoperative CT and three-dimensional reconstruction were performed. Pelvic model was created by 3D printing. Data including the best entry points, plate position and direction and length of screw were obtained from simulated operation based on 3D printing pelvic model. The diaplasis and internal fixation were performed by minimal invasive para-rectus abdominis approach according to the optimized dada in real surgical procedure. Matta and Majeed score were used to evaluate currative effects after operation. According to the Matta standard, the outcome of the diaplasis achieved 97.37% with excellent and good. Majeed assessment showed 94.4% with excellent and good. The imageological examination showed consistency of internal fixation and simulated operation. The mean operation time was 110 minutes, mean intraoperative blood loss 320 ml, and mean incision length 6.5 cm. All patients have achieved clinical healing, with mean healing time of 8 weeks. Three-dimensional printing assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach is feasible and effective. This method has the advantages of trauma minimally, bleeding less, healing rapidly and satisfactory reduction, and worthwhile for spreading in clinical practice.

  8. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    PubMed

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  9. Rational choice of peritoneal dialysis catheter.

    PubMed

    Dell'Aquila, Roberto; Chiaramonte, Stefano; Rodighiero, Maria Pia; Spanó, Emilia; Di Loreto, Pierluigi; Kohn, Catalina Ocampo; Cruz, Dinna; Polanco, Natalia; Kuang, Dingwei; Corradi, Valentina; De Cal, Massimo; Ronco, Claudio

    2007-06-01

    The peritoneal catheter should be a permanent and safe access to the peritoneal cavity. Catheter-related problems are often the cause of permanent transfer to hemodialysis (HD) in up to 20% of peritoneal dialysis (PD) patients; in some cases, these problems require a temporary period on HD. Advances in connectology have reduced the incidence of peritonitis, and so catheter-related complications during PD have become a major concern. In the last few years, novel techniques have emerged in the field of PD: new dialysis solutions, better connectology, and cyclers for automated PD. However, extracorporeal dialysis has continued to improve in terms of methods and patient survival, but PD has failed to do so. The main reason is that peritoneal access has remained problematical. The peritoneal catheter is the major obstacle to wide-spread use of PD. Overcoming catheter-related problems means giving a real chance to development of the peritoneal technique. Catheters should be as efficient, safe, and acceptable as possible. Since its introduction in the mid-1960s, the Tenckhoff catheter has not become obsolete: dozens of new models have been proposed, but none has significantly reduced the pre-dominance of the first catheter. No convincing prospective data demonstrate the superiority of any peritoneal catheter, and so it seems that factors other than choice of catheter are what affect survival and complication rates. Efforts to improve peritoneal catheter survival and complication rates should probably focus on factors other than the choice of catheter. The present article provides an overview of the characteristics of the best-known peritoneal catheters.

  10. Acute urinary retention: which catheter?

    PubMed Central

    Allardice, J. T.; Standfield, N. J.; Wyatt, A. P.

    1988-01-01

    There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory. PMID:3207328

  11. Echogenic Catheters and Embryo Transfer Standardization.

    PubMed

    Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge

    2015-05-01

    1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.

  12. Central venous catheter-associated bloodstream infections in a pediatric intensive care unit: effect of the location of catheter insertion.

    PubMed

    Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan

    2012-05-01

    To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.

  13. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    PubMed

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  14. Bilateral Subpectoral Interfascial Plane Catheters for Analgesia for Sternal Fractures: A Case Report.

    PubMed

    Raza, Irfan; Narayanan, Madankumar; Venkataraju, Arun; Ciocarlan, Alexandra

    2016-01-01

    Sternal fractures occur after deceleration injuries such as falls and road traffic accidents. Recovery from isolated fractures is excellent, but mortality increases dramatically with concurrent chest injuries such as rib fractures and soft tissue injuries. Short-term complications include chest pain, which prevents patients from taking deep breaths and coughing, thereby predisposing them to chest infections. We present a case of a 73-year-old woman with sternal fracture in whom enteral analgesia was inadequate and who was intolerant to intravenous opiates. The patient was successfully treated with a continuous infusion of local anesthetic into the subpectoral interfascial plane. We also discuss the use and potential benefits of the subpectoral interfascial plane block in the treatment of pain from sternal fractures.

  15. Do various baseline characteristics of transversus abdominis and lumbar multifidus predict clinical outcomes in nonspecific low back pain? A systematic review.

    PubMed

    Wong, Arnold Y L; Parent, Eric C; Funabashi, Martha; Stanton, Tasha R; Kawchuk, Gregory N

    2013-12-01

    Although individual reports suggest that baseline morphometry or activity of transversus abdominis or lumbar multifidus predict clinical outcome of low back pain (LBP), a related systematic review is unavailable. Therefore, this review summarized evidence regarding the predictive value of these muscular characteristics. Candidate publications were identified from 6 electronic medical databases. After review, 5 cohort studies were included. Although this review intended to encompass studies using different muscle assessment methods, all included studies coincidentally used ultrasound imaging. No research investigated the relation between static morphometry and clinical outcomes. Evidence synthesis showed limited evidence supporting poor baseline transversus abdominis contraction thickness ratio as a treatment effect modifier favoring motor control exercise. Limited evidence supported that high baseline transversus abdominis lateral slide was associated with higher pain intensity after various exercise interventions at 1-year follow-up. However, there was limited evidence for the absence of relation between the contraction thickness ratio of transversus abdominis or anticipatory onset of lateral abdominal muscles at baseline and the short- or long-term LBP intensity after exercise interventions. There was conflicting evidence for a relation between baseline percent thickness change of lumbar multifidus during contraction and the clinical outcomes of patients after various conservative treatments. Given study heterogeneity, the small number of included studies and the inability of conventional greyscale B-mode ultrasound imaging to measure muscle activity, our findings should be interpreted with caution. Further large-scale prospective studies that use appropriate technology (ie, electromyography to assess muscle activity) should be conducted to investigate the predictive value of morphometry or activity of these muscles with respect to LBP-related outcomes measures

  16. [Urinary catheter biofilm infections].

    PubMed

    Holá, V; Růzicka, F

    2008-04-01

    Urinary tract infections, most of which are biofilm infections in catheterized patients, account for more than 40% of hospital infections. Bacterial colonization of the urinary tract and catheters causes not only infection but also other complications such as catheter blockage by bacterial encrustation, urolithiasis and pyelonephritis. About 50% of long-term catheterized patients face urinary flow obstruction due to catheter encrustation, but no measure is currently available to prevent it. Encrustation has been known either to result from metabolic dysfunction or to be of microbial origin, with urease positive bacterial species implicated most often. Infectious calculi account for about 15-20% of all cases of urolithiasis and are often associated with biofilm colonization of a long-term indwelling urinary catheter or urethral stent. The use of closed catheter systems is helpful in reducing such problems; nevertheless, such a system only delays the inevitable, with infections emerging a little later. Various coatings intended to prevent the bacterial adhesion to the surface of catheters and implants and thus also the emergence of biofilm infections, unfortunately, do not inhibit the microbial adhesion completely and permanently and the only reliable method for biofilm eradication remains the removal of the foreign body from the patient.

  17. [Rotational stability of angiography catheters].

    PubMed

    Schröder, J; Weber, M

    1992-10-01

    Rotatory stability is a parameter that reflects the ability of a catheter to transmit a rotation applied at the outer end to the catheter tip for the purpose of selective probing. A method for measuring the rotatory stability is described, and the results of rotatory stability measurements of 70 different commercially available catheters are reported. There is an almost linear correlation between the rotatory stability and the difference between the respective fourth power of the external and internal diameter or, approximately, to the fourth power of the external diameter for catheters without wire reinforcement. With the same cross-sectional dimensions, the rotatory stability of teflon, polyethylene, and nylon catheters has an approximate ratio of 1:2:4. Wire reinforcement increases rotatory stability by an average factor of about 3. For catheters of calibers 5 F and 6 F, a correlation between the rotatory stability and the weight of the reinforcing wire mesh is apparent.

  18. Bladder Morphology Using 2 Different Catheter Designs

    ClinicalTrials.gov

    2017-04-10

    Urologic Injuries; Urologic Diseases; Bladder Infection; Urinary Tract Infections; Mucosal Inflammation; Mucosal Infection; Bladder Injury; Catheter-Related Infections; Catheter Complications; Catheter; Infection (Indwelling Catheter); Pelvic Floor Disorders; Urinary Incontinence

  19. Embryo Transfer Catheters: Softer is Easier.

    PubMed

    Ruhlmann, Claudio; Gnocchi, Diego C; Cattaneo, Antonio R; Molina, Lucas G; Rivadeneira, Luciano Ruiz; Tessari, Lautaro; Martínez, Alejandro G

    2015-11-01

    This study aimed to compare the use of semi-rigid and flexible catheters in terms of pregnancy rate and level of difficulty of the embryo transfer (ET) procedure. Seven hundred and thirty-nine consecutive follicular aspirations for IVF or ICSI performed in our private fertility clinic within a 30-month period were randomly divided into two groups. Patients were allocated to either of the groups at the time of follicular retrieval with the aid of a random number generator according to the catheter used in ET: Group 1 (n = 370) - Frydman Classic Catheter 4.5 catheters; and Group 2 (n = 369) - Frydman Ultrasoft 4.5 catheters. Only patients offered ET in the randomized cycle were included (Group 1 = 363 and Group 2 = 340). Patients did not change groups after catheter allocation. Statistical analysis was carried out using an unpaired t-test or a chi square test as appropriate. Differences with P<0.05 were considered. A statistically significant difference in favor of the use of the Ultrasoft catheter was evident for parameters use of a tenaculum (19.8% vs. 5.9%) or a hysterometer (5.0% vs. 1.2%), presence of blood during post-ET inspection of the catheter (9.9% vs. 3.8%), and implantation rate (13.0% vs. 16.4%). Clinical pregnancy and delivery rates were comparable in both groups. Our results suggest that a softer catheter may help with difficult ETs. Softer catheters, as also reported by other authors, resulted in better implantation rates.

  20. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    PubMed

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Catheter-related bloodstream infection with removal of catheter in pediatric oncology patients: a 10-year experience in Taiwan.

    PubMed

    Chen, Shih-Hsiang; Yang, Chao-Ping; Jaing, Tang-Her; Lai, Jin-Yao; Hung, Iou-Jih

    2012-04-01

    Long-term central venous catheter (CVC) implantation has become more affordable in Taiwan since 1995. Surgical removal of the catheter may be the essential treatment for catheter-related bloodstream infections (CRBSI). The aim of this study was to evaluate the clinical features and microbial isolates in pediatric cancer patients with removal of CVC for CRBSI. The records of positive blood culture from hospitalized pediatric oncology patients between 1995 and 2004 were reviewed. One hundred and forty-three patients implanted with a long-term CVC were further identified. Seventeen catheters in 16 patients developed catheter-related bacteremia that needed catheter removal. The rate of catheter removal was 11.9%. The median device life was 7.7 months. Six catheters were removed within 3 months of insertion. Nine of the 17 catheters were removed from patient younger than 2 years. Eight infections occurred during severe neutropenia, and 6 patients had refractory or relapsed underlying disease. The cultural isolates were Gram-negative bacilli in 7, Gram-positive in 5, fungi in 5, and atypical mycobacterium in 1. The frequency of catheter removal for infection control was significantly higher in the first 5 years (1994-1999) compared to the last 5 years (2000-2004) (30.9 vs. 4.0%, p = 2.3 × 10(-4)). Factors such as microbiological isolates, age of infection, the status of malignancy, and neutropenia are related to catheter outcome. The reduction in patients with positive cultures needing removal of the catheters can be related to improved nursing care and more aggressive antibiotic therapy.

  2. Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study.

    PubMed

    Arya, Arash; Zaker-Shahrak, Ruzbeh; Sommer, Phillip; Bollmann, Andreas; Wetzel, Ulrike; Gaspar, Thomas; Richter, Sergio; Husser, Daniela; Piorkowski, Christopher; Hindricks, Gerhard

    2011-01-01

    To compare the acute and the 6 month outcome of catheter ablation of atrial fibrillation (AF) using irrigated tip magnetic catheter and remote magnetic cathter navigation (RMN) with manual catheter navigation (MCN) in patients with paroxysmal and persistent AF. In this retrospective analysis 356 patients (235 male, mean age: 57.9 ± 10.9 years) with AF (70.5%, paroxysmal) who underwent catheter ablation between August 2007 and May 2008 using either RMN (n = 70, 46 male, mean age: 57.9 ± 10.1 years, 50% paroxysmal) or MCN (n = 286, 189 male, mean age: 58.0 ± 13.9 years, 75.5% paroxysmal) were included. All patients completed an intensive follow-up strategy. Complete pulmonary vein isolation was achieved in 87.6 and 99.6% of patients in RMN and MCN groups, respectively (P < 0.05). The procedure, fluoroscopy, and radiofrequency application times were 223 ± 44 vs. 166 ± 52 min (P < 0.0001), 13.7 ± 7.8 vs. 34.5 ± 15.1 min (P < 0.0001), and 75.4 ± 20.9 vs. 53.2 ± 21.4 min (P < 0.0001) in RMN and MCN groups, respectively. Seven (10.0%) and 28 (9.8%) patients in RMN and MCN groups received antiarrhythmic medications during the follow-up (P = 0.96). All the patients completed the 6 month follow-up. Freedom from AF at 6 months was achieved in 57.8 and 66.4% of the patients in RMN and MCN groups, respectively (P = 0.196). In patients without previous AF catheter ablation procedure the freedom from AF at 6 months were 68.2 and 60.5% in the MCN and RMN groups, respectively (P = 0.36). Catheter ablation using irrigated tip magnetic catheter and RMN is an effective and safe method for catheter ablation of AF. Compared to manual catheter navigation, the procedure and radiofrequency application times were longer and fluoroscopy time was shorter in the RMN group compared with the MCN group.

  3. Right Lower Quadrant Pain in a Young Female: Ultrasound Diagnosis of Rectus Abdominis Tear.

    PubMed

    Minardi, Joseph; Shaver, Erica; Monseau, Aaron; Pratt, Adam; Layman, Shelley M

    2015-11-01

    Right lower quadrant pain in young females presents a frequent diagnostic challenge for emergency physicians, with a broad differential and several important diagnoses. Using an "ultrasound first" imaging strategy can help decrease the use of computed tomography scans, with associated savings in radiation exposure, cost, and other resource use. We report a case of right lower quadrant pain in a young woman. After her initial history and physical examination, appendicitis was the leading differential. A bedside ultrasound was performed, leading to the uncommon diagnosis of rectus abdominis muscle tear. The sonographic findings of a muscle tear include increase in size, loss of linear, homogeneous architecture, and decreased echogenicity. Making this diagnosis at the bedside using ultrasound obviated the need for further imaging, avoiding unnecessary radiation exposure, and decreasing emergency department length of stay and overall cost, while leading to a tailored treatment plan. Why Should an Emergency Physician Be Aware of This? Rectus abdominis tear is a cause of right lower quadrant pain that may mimic appendicitis and should be considered in patients with this complaint. The ability to make this diagnosis with bedside ultrasound may assist in several important patient-oriented outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Is it feasible to diagnose catheter-related candidemia without catheter withdrawal?

    PubMed

    Fernández-Cruz, Ana; Martín-Rabadán, Pablo; Suárez-Salas, Marisol; Rojas-Wettig, Loreto; Pérez, María Jesús; Guinea, Jesús; Guembe, María; Peláez, Teresa; Sánchez-Carrillo, Carlos; Bouza, Emilio

    2014-07-01

    Many bloodstream infections (BSI) in patients with central venous catheters (CVC) are not catheter-related (CR). Assessment of catheter involvement without catheter withdrawal has not been studied in candidemia. We assessed the value of conservative techniques to evaluate catheters as the origin of candidemia in patients with CVC in a prospective cohort study (superficial Gram stain and culture, Kite technique (Gram stain and culture of the first 1 cm blood drawn from the CVC), proportion of positive blood cultures (PPBCs), differential time to positivity (DTP), and minimal time to positivity (MTP)). All catheters were cultured at withdrawal. From June 2008 to January 2012, 22 cases fulfilled the inclusion criteria. CR-candidemia (CRC) was confirmed in 10. Validity values for predicting CRC were: superficial Gram stain (S, 30%; Sp, 81.83%; PPV, 60%; NPV, 56.3%; Ac, 57.1%), superficial cultures (S, 40%; Sp, 75%; PPV, 57.1%; NPV, 60%; Ac, 59.1%), Kite Gram stain (S, 33.3%; Sp, 66.7%; PPV, 50%; NPV, 50%; Ac, 50%), Kite culture (S, 80%; Sp, 66.7%; PPV, 66.7%; NPV, 80%; Ac, 72.7%), PPBC (S, 50%; Sp, 41.7%; PPV, 41.7%; NPV, 50.0%; Ac, 45.5%), DTP (S, 100%; Sp, 33.3%; PPV, 55.6%; NPV, 100%; Ac, 63.6%), and MTTP (S, 70%; Sp, 58.3%; PPV, 58.3%; NPV, 70%; Ac, 63.6%). While combinations of two tests improved sensitivity and NPV, more than two tests did not improve validity values. Classic tests to assess CR-BSI caused by bacteria cannot be reliably used to diagnose CRC. Combinations of tests could be useful, but more and larger studies are required. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Comparing the effectiveness of ropivacaine 0.5% versus ropivacaine 0.2% for transabdominis plane block in providing postoperative analgesia after appendectomy.

    PubMed

    Abdul Jalil, Reymi Marseela; Yahya, Nurlia; Sulaiman, Omar; Wan Mat, Wan Rahiza; Teo, Rufinah; Izaham, Azarinah; Rahman, Raha Abdul

    2014-06-01

    The basis for the transversus abdominis plane (TAP) block involves infiltration of a local anesthetic into the neurofascial plane between the internal oblique and the transversus abdominis muscles, causing a regional block that spreads between the L1 and T10 dermatomes. Thus, the TAP block is said to be suitable for lower abdominal surgery. This study was designed to compare the analgesic efficacy of two different concentrations of ropivacaine for TAP block in patients undergoing appendectomy. Fifty-six patients with American Society of Anesthesiologists physical status I or II, aged 18 years and above, undergoing appendectomy were recruited in this prospective, randomized, double-blind study. They were divided into two groups: Group A patients who received 0.5 mL/kg of ropivacaine 0.5% and Group B patients who received 0.5 mL/kg of ropivacaine 0.2% via TAP block under ultrasound guidance. Postoperative pain was assessed using the visual analog scale upon arrival at the recovery room in the operating theatre, just prior to being discharged to the ward, and at 6 hours, 12 hours, 18 hours, and 24 hours postoperatively to compare the effectiveness of analgesia. Intraoperatively, patients in Group B required a significantly greater amount of additional intravenous fentanyl than those in Group A. There were no significant statistical differences in pain scores at rest and on movement at all assessment times as well as in the dose of 24-hour intravenous morphine consumption given via patient-controlled analgesia postoperatively between the two groups. The effectiveness of two different concentrations of ropivacaine (0.5% versus 0.2%) given via TAP block was comparable in providing postoperative analgesia for patients undergoing appendectomy. Copyright © 2014. Published by Elsevier B.V.

  6. Ultrasound-guided Combined Fascial Plane Blocks as an Intervention for Pain Management after Laparoscopic Cholecystectomy: A Randomized Control Study

    PubMed Central

    Ramkiran, Seshadri; Jacob, Mathews; Honwad, Manish; Vivekanand, Desiraju; Krishnakumar, Mathangi; Patrikar, Seema

    2018-01-01

    Background: Pain associated with laparoscopic cholecystectomy is most severe during the first 24 h and the port sites are the most painful. Recent multimodal approaches target incisional pain instead of visceral pain which has led to the emergence of abdominal fascial plane blocks. This study embraces a novel combination of two independently effective fascial plane blocks, namely rectus sheath block and subcostal transversus abdominis plane (TAP) block to alleviate postoperative pain. Study Objective: The aim is to evaluate the effectiveness of the combination of rectus sheath block and subcostal TAP block, to compare its efficacy with that of subcostal TAP block alone and with conventional port site infiltration (PSI) in alleviating postoperative pain in patients undergoing laparoscopic cholecystectomy. Methodology: This prospective, randomized control, pilot study included 61 patients scheduled for elective laparoscopic cholecystectomy and distributed among three groups, namely Group 1: Combined subcostal TAP block with rectus sheath block (n = 20); Group 2: Oblique subcostal TAP block alone (n = 21); and Group 3: PSI group as an active control (n = 20). Results: Combined group had significantly lower pain scores, higher satisfaction scores, and reduced rescue analgesia both in early and late postoperative periods than the conventional PSI group. Conclusion: Ultrasound-guided combined fascial plane blocks is a novel intervention in pain management of patients undergoing laparoscopic cholecystectomy and should become the standard of care. PMID:29628547

  7. Evaluation of urinary catheters coated with sustained-release varnish of chlorhexidine in mitigating biofilm formation on urinary catheters in dogs.

    PubMed

    Segev, G; Bankirer, T; Steinberg, D; Duvdevani, M; Shapur, N K; Friedman, M; Lavy, E

    2013-01-01

    Biofilm formation occurs commonly on urinary catheters. To assess the efficacy of urinary catheters coated with sustained-release varnish of chlorhexidine in decreasing catheter-associated biofilm formation in dogs. Thirty client-owned dogs. Prospective study. Thirteen dogs were catheterized with urinary catheters coated with sustained-release varnish of chlorhexidine (study group), and 13 dogs were catheterized with an untreated urinary catheter (control group). Presence and intensity of biofilm formation on the urinary catheters were assessed and compared between the groups by evaluating colony-forming units (CFU) of biofilm bacteria, and semiquantitatively, using confocal laser scanning microscopy and electron microscopy. None of the dogs experienced adverse effects associated with the presence of the urinary catheters. Median CFU count of biofilm bacteria at all portions of the urinary catheter was significantly (P < .001) lower in the study compared with the control group. The degree of biofilm formation on the urinary catheters, as evaluated by confocal laser scanning microscopy and electron microscopy, was significantly lower in the study compared with the control group. Electron microscopy examination identified crystals on some of the urinary catheters. The proportion of catheters on which crystals were observed was significantly lower on the distal part of the urinary catheter in the study group compared with the control group (16.7% versus 66.7%, respectively; P = .04). Chlorhexidine sustained-release varnish-coated urinary catheters effectively decrease urinary catheter-associated biofilm formation in dogs. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  8. Toxicity testing of urinary catheters.

    PubMed

    Talja, M; Andersson, L C; Ruutu, M; Alfthan, O

    1985-10-01

    The tissue toxicity of 23 urinary catheter batches (6 latex and 2 non-latex brands) was tested in vitro and in vivo. In vitro, a human T-cell leukemia line (JM) was cultured in the presence of different concentrations of eluates made from the catheters. The cytotoxicity of the eluates was assessed from their ability to inhibit DNA synthesis measured by incorporation of 3H-thymidine. In vivo, two methods were used. Strips of catheters were implanted into the rabbit dorsal muscle and pieces of catheters were implanted into the rat peritoneal cavity. After four days, the foreign body reaction, type of inflammation and necrosis were quantified macroscopically and by light microscopy. The results of the in vitro cytotoxicity test were correlated with those of in vivo methods. The rat peritoneal implantation test correlated better with the cell culture test (P less than 0.01) than with the rabbit muscle implantation test (P less than 0.05). Based on the clinical experience of urethral stricture complications caused by urinary catheters, catheters yielding eluate which at 30% dilution inhibited 50% DNA synthesis were regarded as toxic. According to this, the rabbit muscle implantation test was not reliable in testing the tissue toxicity of urinary catheters, while the cell culture test was quantitative and seemed to correlate with both the rat peritoneal implantation test and with the clinical complications observed.

  9. Catheter-associated urinary tract infection.

    PubMed

    Tambyah, Paul A; Oon, Jolene

    2012-08-01

    Catheter-associated urinary tract infection (CAUTI) is the commonest nosocomial infection worldwide. Here we review the recent advances in the prevention of CAUTI. After more than 30 years, new guidelines were issued in 2008-2011 by the Infectious Diseases Society of America, Society for Healthcare Epidemiology of America, Healthcare Infection Control Practices Advisory Committee and European Association of Urology. These guidelines addressed novel technologies such as silver alloy or antimicrobial coatings on catheters, hydrophilic catheters, urethral stents, use of sealed catheter-tube junctions and antiinfective bladder irrigation. In addition, multiple trials have been published recently on the reduction of inappropriate urinary tract catheterization. Numerous strategies have been developed to reduce the incidence of CAUTI but few have proven effective. Reducing the inappropriate use of catheters and development of novel technologies targeted against these increasingly multidrug-resistant pathogens may be useful in the prevention of CAUTI in our vulnerable patients.

  10. Insertion of tunneled hemodialysis catheters without fluoroscopy.

    PubMed

    Motta Elias, Rosilene; da Silva Makida, Sonia Cristina; Abensur, Hugo; Martins Castro, Manuel Carlos; Affonso Moysés, Rosa Maria; Pereira, Benedito Jorge; Bueno de Oliveira, Rodrigo; Luders, Cláudio; Romão, João Egidio

    2010-01-01

    The tunneled cuffed catheter (TCC) is used as a bridge access for hemodialysis. Few prospective studies have been designed to evaluate conversion from non-tunneled to TCC without the use of fluoroscopy when performed by nephrologists. We performed an observational prospective cohort in incident patients receiving hemodialysis through a non-tunneled right jugular vein catheter. 130 procedures were performed in 122 patients (51+/-18 years). The success rate was 100%. There was a total of 26,546 catheter days. Ninety-one of the 130 catheters were removed during the study period. Life table analysis revealed primary patency rates of 92%, 82%, and 68% at 30, 60, and 120 days, respectively. Infection requiring catheter removal occurred at a frequency of 0.09 per 100 catheter days. Catheter malfunction requiring intervention occurred at a rate of 0.03 per 100 catheter days. Hypertension and duration of existing non-tunneled catheter of less than 2 weeks were independently associated with better TCC survival. The conversion from non-tunneled to TCC performed by nephrologists and without fluoroscopy may be safe by using the internal right jugular vein. The ideal time to do this procedure is within less than 2 weeks of existing non-tunneled catheter.

  11. Bacterial contamination of epidural catheters: microbiological examination of 502 epidural catheters used for postoperative analgesia.

    PubMed

    Steffen, Peter; Seeling, Wulf; Essig, Andreas; Stiepan, Erika; Rockemann, Michael Georg

    2004-03-01

    To investigate the frequency of bacterial colonization of epidural catheters used for postoperative pain treatment longer than 24 hours in abdominal, thoracic, or trauma surgery patients. Retrospective study. Intermediate care facility and general ward of a university hospital. 502 patients who received epidural catheters after abdominal, thoracic, or vascular surgery at our institution from January 1996 to December 2000. Placement of an epidural catheter, which was used for postoperative pain treatment, for more than 24 hours. The puncture site dressing included saturation each day with povidone-iodine. Microbiologic monitoring of epidural catheter tips and daily examination of puncture sites with regard to signs of inflammation took place. Four times daily patients were examined to check adequacy of pain treatment and neurologic deficits. Catheter tip cultures were positive in 29 patients (5.8%). Staphylococcus epidermidis was isolated in 22 cases (76%). No case of spinal epidural abscess was observed within 6 months after epidural catheterization. The average catheterization time was 5 days (quartile range: 4 to 6 days). Meticulous management ensures a relatively low level of bacterial contamination in epidural catheters applied for postoperative pain treatment greater than 5 days. Contamination rarely leads to spinal epidural infection.

  12. Large eccentric laser angioplasty catheter

    NASA Astrophysics Data System (ADS)

    Taylor, Kevin D.; Reiser, Christopher

    1997-05-01

    In response to recent demand for increased debulking of large diameter coronary vascular segments, a large eccentric catheter for excimer laser coronary angioplasty has been developed. The outer tip diameter is 2.0 mm and incorporates approximately 300 fibers of 50 micron diameter in a monorail- type percutaneous catheter. The basic function of the device is to ablate a coronary atherosclerotic lesion with 308 nm excimer laser pulses, while passing the tip of the catheter through the lesion. By employing multiple passes through the lesion, rotating the catheter 90 degrees after each pass, we expect to create luminal diameters close to 3 mm with this device. Design characteristics, in-vitro testing, and initial clinical experience is presented.

  13. Minilaparotomy salvage of malfunctioning catheters in peritoneal dialysis.

    PubMed

    Li, Jian-Ri; Cheng, Chi-Hung; Chiu, Kun-Yuan; Cheng, Chen-Li; Yang, Chi-Rei; Ho, Hao-Chung; Ko, Jiunn-Liang; Ou, Yen-Chuan

    2013-01-01

    Catheter malfunction is a common and significant complication during peritoneal dialysis (PD). We developed a minilaparotomy procedure to rescue malfunctioning catheters and to prevent recurrence of malfunction. From 2006 to 2011, 11 patients receiving PD had a malfunctioning catheter. In all patients, a 2-cm incision, 5 cm caudally to the previous peritoneal entry site was used to correct the malfunctioning catheter, with concomitant fixation of the catheter to the peritoneum. Catheter tip migration occurred in 7 patients, omental wrapping in 3, and blood clot obstruction in 1. The mean onset time to catheter malfunction was 197.5 days (range: 4 - 1270 days), and the mean operating time was 41 minutes (range: 35 - 56 minutes). There was no recurrence of catheter malfunction and no surgery-related peritonitis. Our minilaparotomy procedure is safe and feasible for the salvage of malfunctioning PD catheters.

  14. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    PubMed

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  15. Pedicled rectus abdominis muscle and fascia flap sling the bulbar urethra for treatment for male-acquired urinary incontinence: report of ten cases.

    PubMed

    Xu, Yue-Min; Zhang, Xin-Ru; Xie, Hong; Song, Lu-Jie; Feng, Chao; Fei, Xiao-Fang

    2014-03-01

    Male urinary incontinence is relatively common complication of radical prostatectomy and of posterior urethroplasty following traumatic pelvic fracture. Here, we investigate the use of pedicled rectus abdominis muscle and fascia flap sling of the bulbar urethra for treatment for male-acquired urinary incontinence. Ten patients with acquired urinary incontinence were included in the study. Urinary incontinence was secondary to TURP in three patients and was secondary to posterior urethroplasty performed following traumatic pelvic fracture in seven patients. Pedicled rectus abdominalis muscle and fascial flaps, approximately 2.5 cm wide and 15 cm long, were isolated. The flaps were inserted into a perineal incision through a subcutaneous tunnel. The free end of the flap was sectioned to form two muscle strips, each 3 cm in length, and inserted into the space between bulbar urethra and corpus cavernosa. After adequate sling tension had been achieved, the two strips of muscle were anastomosed around the bulbar urethra using a 2-zero polyglactin suture. The patients were followed up for between 12 and 82 months (mean 42.8 months). Complete continence was achieved with good voiding in seven of the 10 patients. In other three patients achieved good voiding following catheter removal, but incontinence was only moderately improved. A pedicled rectus muscle fascial sling of the bulbar urethra is an effective and safe treatment for male patients with mild to moderate acquired urinary incontinence, but it may not be suitable for severe incontinence or for patients with weak rectus abdominalis muscles.

  16. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This..., coude catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters...

  17. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  18. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  19. 21 CFR 870.1210 - Continuous flush catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1210 Continuous flush catheter. (a) Identification. A continuous flush catheter is an attachment to a catheter-transducer system...

  20. Anti-fouling strategies for central venous catheters

    PubMed Central

    Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-01-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs. PMID:29399528

  1. Anti-fouling strategies for central venous catheters.

    PubMed

    Wallace, Alex; Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi

    2017-12-01

    Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs.

  2. Outcomes after peritoneal dialysis catheter placement.

    PubMed

    Carpenter, Jennifer L; Fallon, Sara C; Swartz, Sarah J; Minifee, Paul K; Cass, Darrell L; Nuchtern, Jed G; Pimpalwar, Ashwin P; Brandt, Mary L

    2016-05-01

    The purpose of this study was to review surgical outcomes after elective placement of peritoneal dialysis (PD) catheters in children with end-stage renal disease. Children with PD catheters placed between February 2002 and July 2014 were retrospectively reviewed. Outcomes were catheter life, late (>30days post-op) complications (catheter malfunction, catheter malposition, infection), and re-operation rates. Comparison groups included laparoscopic versus open placement, age<2, and weight<10kg. Univariate and multivariate analysis were performed. One hundred sixteen patients had 173 catheters placed (122 open, 51 laparoscopic) with an average patient age of 9.7±6.3years. Mean catheter life was similar in the laparoscopic and open groups (581±539days versus 574±487days, p=0.938). The late complication rate was higher for open procedures (57% versus 37%, p=0.013). Children age<2 or weight<10kg had higher re-operation rates (64% versus 42%, p=0.014 and 73% versus 40%, p=0.001, respectively). Adjusted for age and weight, open technique remained a risk factor for late complications (OR 2.44, 95% CI 1.20-4.95) but not re-operation. Laparoscopic placement appears to reduce the rate of late complications in children who require PD dialysis catheters. Children <2years age or <10kg remain at risk for complications regardless of technique. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Advanced Imaging Catheter: Final Project Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krulevitch, P; Colston, B; DaSilva, L

    2001-07-20

    Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area.more » The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body

  4. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  5. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  6. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  7. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  8. 21 CFR 870.1200 - Diagnostic intravascular catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... intracardiac pressures, to sample blood, and to introduce substances into the heart and vessels. Included in this generic device are right-heart catheters, left-heart catheters, and angiographic catheters, among...

  9. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    PubMed

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (p<0.001). Perfusion of amiodarone [adjusted OR (AOR) 25.97; 95% CI=7.29-92.55, p=0.0001] and cefotaxime (AOR 2.90; 95% CI=1.29-6.52, p=0.01) and the shift when the catheters were placed (AOR for morning vs. night shift 0.60; 95% CI=0.35-1.02, p=0.063) were independently associated to the development of PPIVC. A history of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  10. Prevention of catheter-related blood stream infection.

    PubMed

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  11. Prevention of catheter-associated urinary tract infection

    PubMed Central

    Trautner, Barbara W.; Hull, Richard A.; Darouiche, Rabih O.

    2010-01-01

    Purpose of review The underlying cause of catheter-associated urinary tract infection is biofilm formation by uropathogens on the urinary catheter. Biofilm is a relatively new concept in medicine, and current measures to prevent biofilm formation are inadequate. Considerable work is being done in this area, but little clinical progress has been made. The purpose of this review is to analyze recent publications concerning prevention of catheter-associated urinary tract infection. Recent findings Several recent studies have elucidated aspects of biofilm formation in catheter-associated urinary tract infection. Other researchers are working on methods to disrupt biofilm formation on catheter surfaces. At the same time, the magnitude of the problem of catheter-associated urinary tract infection has increased awareness of the effectiveness of basic infection control measures. A modern approach to infection control may include computerized ordering systems that minimize unnecessary days of catheterization. Finally, consumption of cranberry juice products and bacterial interference are two novel approaches to urinary tract infection prevention. Summary Biofilm-disrupting strategies offer promise for the future but have little immediate applicability. Implementation of infection control measures to improve catheter function and remove unnecessary catheters can be done at the present time. In general, prevention of catheter-associated urinary tract infection remains an elusive goal. More basic research at the level of pathogenesis is needed so that novel strategies can be designed. PMID:15647698

  12. FAQs about Catheter-Associated Urinary Tract Infection

    MedlinePlus

    ... and nurses take the following actions. Catheter insertion o Catheters are put in only when necessary and they are removed as soon as possible. o Only properly trained persons insert catheters using sterile (“ ...

  13. Central Venous Catheter (Central Line)

    MedlinePlus

    ... the skin entry site. With care, central venous catheters can remain in the body for several months without becoming infected. ■ ■ Blocking or kinking— Blood clots may begin to form in the catheter but ...

  14. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    PubMed Central

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  15. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions.

    PubMed

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-31

    BACKGROUND During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. CASE REPORT We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. CONCLUSIONS This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability, safety, and exchangeability of the device.

  16. Analysis of fiber type transformation and histology in chronic electrically stimulated canine rectus abdominis muscle island-flap stomal sphincters.

    PubMed

    Majzoub, Ramsey K; Bardoel, Janou W J M; Maldonado, Claudio; Barker, John H; Stadelmann, Wayne K

    2003-01-01

    Dynamic skeletal muscle flaps are designed to perform a specific functional task through contraction and relaxation of their muscle fibers. The most commonly used dynamic skeletal flaps today are for cardiomyoplasty and anal or urinary myoplasty. Low-frequency chronic stimulation of these flaps enables them to use their intrinsic energy stores in a more efficient manner through aerobic metabolic pathways for increased endurance and improved work capacity. The purpose of this study was to (1) determine whether fiber type transformation from fatigue-prone (type II) muscle fibers to fatigue-resistant (type I) muscle fibers could be demonstrated in the authors' chronic canine stomal sphincter model where the rectus abdominis muscle was used to create a functional stomal sphincter, (2) assess whether there is any correlation between the degree of muscle fiber type transformation and the continence times, and (3) examine the long-term effects of the training regimens on the skeletal muscle fibers through histologic and volumetric analysis. Eight dynamic island-flap sphincters were created from a part of the rectus abdominis muscle in mongrel dogs by preserving the deep inferior epigastric vascular pedicle and the most caudal investing intercostal nerve. The muscular sphincters were wrapped around a blind loop of distal ileum and trained with pacing electrodes. Two different training protocols were used. In group A (n = 4), a preexisting anal dynamic graciloplasty training protocol was used. A revised protocol was used in group B (n = 4). Muscle biopsy specimens were obtained before and after training from the rectus abdominis muscle sphincter. Fiber type transformation was assessed using a monoclonal antibody directed against the fatigue-prone type II fibers. Pretraining and posttraining skeletal muscle specimens were examined histologically. A significant fiber type conversion was achieved in both group A and group B animals, with each group achieving greater than 50

  17. [Peripheral intravenous catheter-related phlebitis].

    PubMed

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  18. Catheter-based photoacoustic endoscope

    PubMed Central

    Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2014-01-01

    Abstract. We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique’s benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument’s flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system. PMID:24887743

  19. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  20. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  1. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  2. S-Nitroso-N-acetylpenicillamine (SNAP) Impregnated Silicone Foley Catheters: A Potential Biomaterial/Device To Prevent Catheter-Associated Urinary Tract Infections

    PubMed Central

    2016-01-01

    Urinary Foley catheters are utilized for management of hospitalized patients and are associated with high rates of urinary tract infections (UTIs). Nitric oxide (NO) potently inhibits microbial biofilm formation, which is the primary cause of catheter associated UTIs (CAUTIs). Herein, commercial silicone Foley catheters are impregnated via a solvent swelling method with S-nitroso-N-acetyl-D-penicillamine (SNAP), a synthetic NO donor that exhibits long-term NO release and stability when incorporated into low water-uptake polymers. The proposed catheters generate NO surface-fluxes >0.7 × 10–10 mol min–1 cm–2 for over one month under physiological conditions, with minimal SNAP leaching. These biomedical devices are demonstrated to significantly decrease formation of biofilm on the surface of the catheter tubings over 3, 7, and 14 day periods by microbial species (Staphylococcus epidermidis and Proteus mirabilis) commonly causing CAUTIs. Toxicity assessment demonstrates that the SNAP-impregnated catheters are fully biocompatible, as extracts of the catheter tubings score 0 on a 3-point grading scale using an accepted mouse fibroblast cell-line toxicity model. Consequently, SNAP-impregnated silicone Foley catheters can likely provide an efficient strategy to greatly reduce the occurrence of nosocomial CAUTIs. PMID:26462294

  3. Early removal of urethral catheter with suprapubic tube drainage versus urethral catheter drainage alone after robot-assisted laparoscopic radical prostatectomy.

    PubMed

    Prasad, Sandip M; Large, Michael C; Patel, Amit R; Famakinwa, Olufenwa; Galocy, R Matthew; Karrison, Theodore; Shalhav, Arieh L; Zagaja, Gregory P

    2014-07-01

    Retrospective single institution data suggest that postoperative pain after robot-assisted laparoscopic radical prostatectomy is decreased by early removal of the urethral catheter with suprapubic tube drainage. In a randomized patient population we determined whether suprapubic tube drainage with early urethral catheter removal would improve postoperative pain compared with urethral catheter drainage alone. Men with a body mass index of less than 40 kg/m(2) who had newly diagnosed prostate cancer and elected robot-assisted laparoscopic radical prostatectomy were included in analysis. Block randomization by surgeon was used and randomization assignment was done after completing the urethrovesical anastomosis. In patients assigned to suprapubic tube drainage the urethral catheter was removed on postoperative day 1 and all catheters were removed on postoperative day 7. Visual analog pain scale and satisfaction questionnaires were administered on postoperative days 0, 1 and 7. A total of 29 patients were randomized to the urethral catheter vs 29 to the suprapubic tube plus early urethral catheter removal at the time of interim futility analysis. Mean visual analog pain scale scores did not differ between the groups at any time point and a similar percent of patients cited the catheter as the greatest bother with nonsignificant differences in treatment related satisfaction. Complications during postoperative week 1 did not vary between the groups. Based on interim results the trial was terminated due to lack of effect. Patients randomized to suprapubic tube vs urethral catheter drainage for the week after prostatectomy had similar pain, catheter related bother and treatment related satisfaction in the perioperative period. We no longer routinely offer suprapubic tube drainage with early urethral catheter removal at our institution. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. The dangers of long-term catheter drainage.

    PubMed

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  5. Do pulmonary artery catheters cause or increase tricuspid or pulmonic valvular regurgitation?

    PubMed

    Sherman, S V; Wall, M H; Kennedy, D J; Brooker, R F; Butterworth, J

    2001-05-01

    There are few quantitative data on the extent or mechanism of pulmonary artery catheter (PAC)-induced valvular dysfunction. We hypothesized that PACs cause or worsen tricuspid and pulmonic valvular regurgitation, and tested this hypothesis by using transesophageal echocardiography. In 54 anesthetized adult patients, we measured color Doppler jet areas of tricuspid regurgitation (TR) in two planes (midesophageal [ME] 4-chamber and right ventricular inflow-outflow views) and pulmonic insufficiency (PI) in one plane (ME aortic valve long-axis view), both before and after we advanced a PAC into the pulmonary artery. Regurgitant jet areas and hemodynamic measurements were compared by using paired t-test. There were no significant changes in blood pressure or heart rate after passage of the PAC. After PAC placement, the mean PI jet area was not significantly increased. The mean TR jet area increased significantly in the right ventricular inflow-outflow view (+0.37 +/- 0.11 cm(2)) (P = 0.0014), but did not increase at the ME 4-chamber view. Seventeen percent of patients had an increase in TR jet area > or =1 cm(2); 8% of patients had an increase in PI jet area >/=1 cm(2). In patients without pulmonic or tricuspid valvular pathology, placement of a pulmonary artery catheter (PAC) worsened tricuspid regurgitation, which is consistently visualized in the right ventricular inflow-outflow view, and often not seen in the midesophageal 4-chamber view. This is consistent with malcoaptation of the anterior and posterior leaflets. PAC-induced pulmonic insufficiency was rarely detected in the midesophageal aortic valve long-axis view. We conclude that a PAC is very unlikely to be the sole cause of severe tricuspid regurgitation or pulmonic insufficiency.

  6. Heart catheter cable and connector

    NASA Technical Reports Server (NTRS)

    Harrison, D. R.; Cota, F. L.; Sandler, H.

    1972-01-01

    Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.

  7. Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: a prospective, randomised, participant-blinded, crossover study of three different types of catheters.

    PubMed

    Stensballe, J; Looms, D; Nielsen, P N; Tvede, M

    2005-12-01

    To compare two hydrophilic-coated (SpeediCath and LoFric and one uncoated gel-lubricated catheter (InCare Advance Plus) concerning withdrawal friction force and urethral micro trauma. 49 healthy male volunteers participated in this prospective, randomised, blinded, crossover study of three different bladder catheters. The withdrawal friction force was measured, and urine analysis of blood, nitrite and leucocytes, microbiological analysis of urine cultures and subjective evaluation of the catheters were performed. 40 participants completed the study and were included in the analysis. SpeediCath exerted a significantly lower mean withdrawal friction force and work than the gel-lubricated uncoated catheter, whereas LoFric exerted a significantly higher mean friction force than both of the other catheters. The hydrophilic catheters caused less microscopic haematuria and less pain than the gel-lubricated uncoated catheter. Furthermore, 93% of the participants preferred the hydrophilic catheters. Hydrophilic-coated catheters perform better than uncoated catheters with regard to haematuria and preference. SpeediCath, but not LoFric, exerts less withdrawal friction force than InCare Advance Plus.

  8. 3D localization of electrophysiology catheters from a single x-ray cone-beam projection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robert, Normand, E-mail: normand.robert@sri.utoronto.ca; Polack, George G.; Sethi, Benu

    2015-10-15

    Purpose: X-ray images allow the visualization of percutaneous devices such as catheters in real time but inherently lack depth information. The provision of 3D localization of these devices from cone beam x-ray projections would be advantageous for interventions such as electrophysiology (EP), whereby the operator needs to return a device to the same anatomical locations during the procedure. A method to achieve real-time 3D single view localization (SVL) of an object of known geometry from a single x-ray image is presented. SVL exploits the change in the magnification of an object as its distance from the x-ray source is varied.more » The x-ray projection of an object of interest is compared to a synthetic x-ray projection of a model of said object as its pose is varied. Methods: SVL was tested with a 3 mm spherical marker and an electrophysiology catheter. The effect of x-ray acquisition parameters on SVL was investigated. An independent reference localization method was developed to compare results when imaging a catheter translated via a computer controlled three-axes stage. SVL was also performed on clinical fluoroscopy image sequences. A commercial navigation system was used in some clinical image sequences for comparison. Results: SVL estimates exhibited little change as x-ray acquisition parameters were varied. The reproducibility of catheter position estimates in phantoms denoted by the standard deviations, (σ{sub x}, σ{sub y}, σ{sub z}) = (0.099 mm,  0.093 mm,  2.2 mm), where x and y are parallel to the detector plane and z is the distance from the x-ray source. Position estimates (x, y, z) exhibited a 4% systematic error (underestimation) when compared to the reference method. The authors demonstrated that EP catheters can be tracked in clinical fluoroscopic images. Conclusions: It has been shown that EP catheters can be localized in real time in phantoms and clinical images at fluoroscopic exposure rates. Further work is required to

  9. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    PubMed

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  10. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  11. 21 CFR 870.1330 - Catheter guide wire.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter guide wire. 870.1330 Section 870.1330...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1330 Catheter guide wire. (a) Identification. A catheter guide wire is a coiled wire that is designed to fit inside a...

  12. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  13. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  14. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  15. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  16. 21 CFR 868.5350 - Nasal oxygen catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...

  17. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    PubMed

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  18. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    PubMed Central

    Urbanetto, Janete de Souza; Peixoto, Cibelle Grassmann; May, Tássia Amanda

    2016-01-01

    ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC) and following their removal - (post-infusion phlebitis) in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective. PMID:27508916

  19. Establishing Immediate Reliability of Sonographic Measurements of the Transversus Abdominis in Asymptomatic Adults Performing Upright Loaded Functional Tasks in a Clinical Context Without Delayed Recorded Measurement.

    PubMed

    McPherson, Sue; Watson, Todd; Pate, Lindsey

    2016-08-01

    This study examined the reliability of sonographic measurements of the transversus abdominis of adults without low back pain during upright loaded functional tasks in real time, without relying on delayed recorded images. A single-group repeated-measures reliability study was conducted on 12 healthy participants without low back pain. Six of these adults reported a prior history of abdominal drawing-in maneuver training without sonographic measurement. The participants performed 3 trials of neutral standing, a loaded forward reach, and a loaded box lift under rest and with abdominal drawing-in maneuver instructions; task order was randomized. Transversus abdominis thickness measurements were obtained by an experienced rater using B-mode sonography in real-time via electronic calipers twice on the same static image during all trials by a rater. The rater was masked to group assignment and on-screen measurement output and required to respond to trivia questions between repeated measurements. The participants included 6 male and 6 female adults with a mean age ± SD of 26.3 ± 3.7 years. Intra-rater intraclass correlation coefficients (2,3) were high and precise for the rater's first and second measurements for all tasks and instruction conditions for mean transversus abdominis thickness and percent change in thickness measurements (eg, ranges were 0.968-0.997 for intraclass correlation coefficients, 0.01-0.21 mm for standard errors of the measurement, and 0.01-0.58 mm for minimal detectable changes). Calipers cleared by the rater or a research assistant produced similar findings of excellent reliability and precision. High intra-rater reliability and precision of transversus abdominis thickness measurements were obtained by a physical therapist in real time from asymptomatic adults performing upright loaded functional tasks under rest and with abdominal drawing-in maneuver instructions.

  20. Donor-Site Complications and Remnant of Rectus Abdominis Muscle Status after Transverse Rectus Abdominis Myocutaneous Flap Reconstruction

    PubMed Central

    Chirappapha, Prakasit; Trikunagonvong, Noppadol; Rongthong, Sasiprapa; Lertsithichai, Panuwat; Sukarayothin, Thongchai; Leesombatpaiboon, Monchai; Panawattanakul, Rujira; Thaweepworadej, Panya

    2017-01-01

    Background: Transverse rectus abdominis myocutaneous (TRAM) flap reconstruction after mastectomy in breast cancer patients has become one of the milestones in breast reconstruction. There are several techniques that have been used in an attempt to minimize untoward complications. We present the whole muscle with partial sheath-sparing technique that focuses on the anatomy of arcuate line and the closure of the anterior abdominal wall techniques with mesh and determine factors associated with its complications and outcomes. Methods: We retrospectively and prospectively review the results of 30 pedicled TRAM flaps that were performed between November 2013 and March 2016, focusing on outcomes and complications. Results: Among the 30 pedicled TRAM flap procedures in 30 patients, there were complications in 5 patients (17%). Most common complications were surgical-site infection (7%). After a median follow-up time of 15 months, no patient developed abdominal wall hernia or bulging in daily activities in our study, but 6 patients (20%) had asymptomatic abdominal wall bulging when exercised. Significant factors related to asymptomatic exercised abdominal wall bulging included having a body mass index of more than 23 kg/m2. Conclusion: Pedicled TRAM flap by using the technique of the whole muscle with partial sheath-sparing technique combined with reinforcement above the arcuate line with mesh can reduce the occurrence of abdominal bulging and hernia. PMID:28740793

  1. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    PubMed

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (p<0.001). The median angles of the catheter tip were 7.8° and 4.1°, respectively (p<0.001). Phlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  2. Development of Bend Sensor for Catheter Tip

    NASA Astrophysics Data System (ADS)

    Nagano, Yoshitaka; Sano, Akihito; Fujimoto, Hideo

    Recently, a minimally invasive surgery which makes the best use of the catheter has been becoming more popular. In endovascular coil embolization for a cerebral aneurysm, the observation of the catheter's painting phenomenon is very important to execute the appropriate manipulation of the delivery wire and the catheter. In this study, the internal bend sensor which consists of at least two bending enhanced plastic optical fibers was developed in order to measure the curvature of the catheter tip. Consequently, the painting could be more sensitively detected in the neighborhood of the aneurysm. In this paper, the basic characteristics of the developed sensor system are described and its usefulness is confirmed from the comparison of the insertion force of delivery wire and the curvature of catheter tip in the experiment of coil embolization.

  3. A novel, inexpensive, double lumen suprapubic catheter for urodynamics.

    PubMed

    Wagner, Andrew A; Godley, Margaret L; Duffy, Patrick G; Ransley, Philip G

    2004-03-01

    We describe a novel, double lumen, intravesical, suprapubic catheter designed to meet the requirements of pediatric urodynamics that is easy to use and has minimal complications. A commercially available 10Fr pediatric suprapubic pigtail catheter forms the outer lumen for instilling filling media. A 16 gauge epidural catheter is inserted through the outer catheter providing an inner lumen for measuring intravesical pressures. The resultant double-lumen catheter is inserted suprapubically using a peel away needle supplied with the 10Fr catheter, with the patient under general anesthetic. The catheter has been used for 15 years in more than 700 patients with good reliability and few complications. The concentric construction of the double lumens and the rigidity of the inner intravesical pressure channel ensure there is no transmission of pressure from the filling channel to the inner lumen. The catheter has a circular cross section and a pigtail distal end which help to retain it within the bladder. There is low resistance to filling that allows adequate filling rates to be achieved by gravity rather than necessitating a pump. The catheter is easily made from readily available components and is less expensive than other double-lumen catheters suitable for suprapubic use. A reliable, double lumen catheter that fulfills criteria not found in commercially available alternatives can be inexpensively made for urodynamics.

  4. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... (a) Identification. An embolectomy catheter is a balloon-tipped catheter that is used to remove thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to...

  5. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  6. Silicon sensors for catheters and guide wires

    NASA Astrophysics Data System (ADS)

    Goosen, Hans F.

    2001-11-01

    One area that can make use of the miniature size of present day micro electromechanical systems (MEMS) is that of the medical field of minimally invasive interventions. These procedures, used for both diagnosis and treatment, use catheters that are advanced through the blood vessels deep into the body, without the need for surgery. However, once inside the body, the doctor performing the procedure is completely reliant on the information the catheter(s) can provide in addition to the projection imaging of a fluoroscope. A good range of sensors for catheters is required for a proper diagnosis. To this end, miniature sensors are being developed to be fitted to catheters and guide wires. As the accurate positioning of these instruments is problematic, it is necessary to combine several sensors on the same guide wire or catheter to measure several parameters in the same location. This however, brings many special problems to the design of the sensors, such as small size, low power consumption, bio-compatibility of materials, robust design for patient safety, a limited number of connections, packaging, etc. This paper will go into both the advantages and design problems of micromachined sensors and actuators in catheters and guide wires. As an example, a multi parameter blood sensor, measuring flow velocity, pressure and oxygen saturation, will be discussed.

  7. [Combination of the ureteral dilation catheter and balloon catheter under the ureteroscope in the treatment of male urethral stricture].

    PubMed

    Zhou, Yi; Li, Gong-hui; Yan, Jia-jun; Shen, Cong; Tang, Gui-hang; Xu, Gang

    2016-01-01

    To investigate the clinical application of the ureteral dilation catheter combined with the balloon catheter under the ureteroscope in the treatment of urethral stricture in men. Under the ureteroscope, 45 male patients with urethral stricture received placement of a zebra guide wire through the strictured urethra into the bladder and then a ureteral dilation catheter along the guide wire, followed by dilation of the urethra from F8 initially to F14 and F16. Again, the ureteroscope was used to determine the length of the strictured urethra, its distance to the external urethral orifice, and whether it was normally located. An F24 balloon catheter and then a metal urethral calibrator was used for the dilation of the strictured urethra. After removal of the F18-F22 urethral catheter at 8 weeks, the urinary flow rate was measured immediately and again at 3 months. All the operations were successfully performed without serious complications. The maximum urinary flow rate was (13.3-29.9) ml/s (mean [17.7 ± 3.2] ml/s) at the removal of the catheter and (15.2-30.8) ml/s (mean [19.8 ± 3.9] ml/s) at 3 months after it. Smooth urination was found in all the patients during the 6-24 months follow-up. The application of the ureteral dilation catheter combined with, the balloon catheter under the ureteroscope is a good option for the treatment of male urethral stricture for its advantages of uncomplicatedness, safety, effectiveness, few complications, less pain, high success rate, and repeatable operation.

  8. Detection of electrophysiology catheters in noisy fluoroscopy images.

    PubMed

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  9. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    PubMed

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  10. Internal Oblique and Transversus Abdominis Muscle Fatigue Induced by Slumped Sitting Posture after 1 Hour of Sitting in Office Workers

    PubMed Central

    Waongenngarm, Pooriput; Rajaratnam, Bala S.; Janwantanakul, Prawit

    2015-01-01

    Background Prolonged sitting leads to low back discomfort and lumbopelvic muscle fatigue. This study examined the characteristics of body perceived discomfort and trunk muscle fatigue during 1 hour of sitting in three postures in office workers. Methods Thirty workers sat for 1 hour in one of three sitting postures (i.e., upright, slumped, and forward leaning postures). Body discomfort was assessed using the Body Perceived Discomfort scale at the beginning and after 1 hour of sitting. Electromyographic (EMG) signals were recorded from superficial lumbar multifidus, iliocostalis lumborum pars thoracis, internal oblique (IO)/transversus abdominis (TrA), and rectus abdominis muscles during 1 hour of sitting. The median frequency (MDF) of the EMG power spectrum was calculated. Results Regardless of the sitting posture, the Body Perceived Discomfort scores in the neck, shoulder, upper back, low back, and buttock significantly increased after 1 hour of sitting compared with baseline values (t(9) = −11.97 to −2.69, p < 0.05). The MDF value of the EMG signal of rectus abdominis, iliocostalis lumborum pars thoracis, and multifidus muscles was unchanged over time in all three sitting postures. Only the right and left IO/TrA in the slumped sitting posture was significantly associated with decreased MDF over time (p = 0.019 to 0.041). Conclusion Prolonged sitting led to increased body discomfort in the neck, shoulder, upper back, low back, and buttock. No sign of trunk muscle fatigue was detected over 1 hour of sitting in the upright and forward leaning postures. Prolonged slumped sitting may relate to IO/TrA muscle fatigue, which may compromise the stability of the spine, making it susceptible to injury. PMID:27014491

  11. Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

    PubMed

    Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J

    2008-07-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.

  12. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions

    PubMed Central

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-01

    Case series Patient: Male, 77 • Male, 57 • Male, 73 Final Diagnosis: Coronary chronic total occlusion Symptoms: Angina pectoris Medication: — Clinical Procedure: Percutaneous coronary intervention of coronary chronic total occlusions Specialty: Cardiology Objective: Unusual setting of medical care Background: During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. Case Report: We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. Conclusions: This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability

  13. Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.

    PubMed

    Macha, Douglas B; Thomas, John; Nelson, Rendon C

    2006-03-01

    To compare the performance characteristics of various single-lumen all-purpose pigtail drainage catheters. The following parameters were compared: flow rates between catheters of the same size, whether changing the fluid viscosity has any effect on catheter comparisons, the effect on flow of leaving an open three-way stopcock in the drainage pathway, the tendency of the catheters to kink, and catheter patency after kinking, as measured according to flow. All-purpose 8.0-, 8.3-, and 8.5-F (collectively referred to as 8-F); 10.0-, 10.2-, and 10.3-F (collectively referred to as 10-F); and 12.0-F pigtail drainage catheters from three manufacturers were evaluated. Data were compared by using two-tailed t tests after normal distributions were confirmed. P < .05 was considered to represent a significant difference. At comparison of the 8-F catheters, the C.R. Bard catheters demonstrated better flow rates than the Cook and Boston Scientific devices. Among the 10-F catheters, there were no significant differences in the flow rates of fluid with viscosity equivalent to that of water between the C.R. Bard and Boston Scientific catheters; however, both these catheter types demonstrated significantly (P < .05) better flow rates than the Cook devices. Among the 12-F catheters, the C.R. Bard catheters demonstrated significantly (P < .05) better flow rates than the other two catheter types. Changing the fluid viscosity caused no changes in comparison results. In all catheter groups, the presence of a stopcock significantly (P < .05) impaired flow. None of the evaluated catheters demonstrated a clear advantage in terms of patency or susceptibility to kinking. At comparison of the in vitro performances of catheters from different manufacturers, the C.R. Bard 8.0-F and Cook 10.2-F catheters had comparable flow rates, and flow rates through the C.R. Bard and Boston Scientific 10.0-F catheters were comparable to flow rates through the Cook and Boston Scientific 12.0-F catheters

  14. Cryo-balloon catheter localization in fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  15. Double Guiding Catheters for Complex Percutaneous Coronary Intervention

    PubMed Central

    Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen

    2012-01-01

    A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243

  16. Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.

    PubMed

    Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim

    2017-05-01

    Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Baclofen pump catheter leakage after migration of the abdominal catheter in a pediatric patient with spasticity.

    PubMed

    Dastgir, Amer; Ranalli, Nathan J; MacGregor, Theresa L; Aldana, Philipp R

    2015-09-01

    The authors report an unusual case of intrathecal baclofen withdrawal due to the perforation and subsequent leakage of a baclofen pump catheter in a patient with spastic cerebral palsy. A 15-year-old boy underwent an uncomplicated placement of an intrathecal baclofen pump for the treatment of spasticity due to cerebral palsy. After excellent control of symptoms for 3 years, the patient presented to the emergency department with increasing tremors following a refill of his baclofen pump. Initial evaluation consisted of radiographs of the pump and catheter, which appeared normal, and a successful aspiration of CSF from the pump's side port. A CT dye study revealed a portion of the catheter directly overlying the refill port and extravasation of radiopaque dye into the subfascial pocket anterior to the pump. During subsequent revision surgery, a small puncture hole in the catheter was seen to be leaking the drug. The likely cause of the puncture was an inadvertent perforation of the catheter by a needle during the refilling of the pump. This case report highlights a unique complication in a patient with an intrathecal baclofen pump. Physicians caring for these patients should be aware of this rare yet potential complication in patients presenting with baclofen withdrawal symptoms.

  18. Balloon catheter versus basket catheter for endoscopic bile duct stone extraction: a multicenter randomized trial.

    PubMed

    Ishiwatari, Hirotoshi; Kawakami, Hiroshi; Hisai, Hiroyuki; Yane, Kei; Onodera, Manabu; Eto, Kazunori; Haba, Shin; Okuda, Toshinori; Ihara, Hideyuki; Kukitsu, Takehiro; Matsumoto, Ryusuke; Kitaoka, Keisuke; Sonoda, Tomoko; Hayashi, Tsuyoshi

    2016-04-01

    Endoscopic bile duct stone (BDS) removal is a well-established treatment; however, the preference for basket or balloon catheters for extraction is operator-dependent. We therefore conducted a multicenter prospective randomized trial to compare catheter performance. We enrolled patients with a BDS diameter ≤ 10 mm and common bile duct diameter ≤ 15 mm. Participants were randomly assigned to groups that were treated with basket or balloon catheters between October 2013 and September 2014. The primary endpoint was the rate of complete clearance of the duct; the secondary endpoints were the rate and time to complete clearance in one endoscopic session. We initially enrolled 172 consecutive patients; 14 were excluded after randomization. The complete clearance rates were 92.3 % (72/78) in the balloon group and 80.0 % (64 /80) in the basket group. The difference in the rates between the two groups was 12.3 percentage points, indicating non-inferiority of the balloon method (non-inferiority limit -10 %; P < 0.001 for non-inferiority). Moreover, the balloon was superior to the basket (P = 0.037). The rate of complete clearance in one endoscopic session was 97.4 % using the balloon and 97.5 % using the basket (P = 1.00). The median times to complete clearance in one endoscopic session were 6.0 minutes (1 - 30) and 7.8 minutes (1 - 37) in the balloon and basket groups, respectively (P = 0.15). For extraction of BDSs ≤ 10 mm, complete endoscopic treatment with a single catheter is more likely when choosing a balloon catheter over a basket catheter.University Hospital Medical Information Network Trials Registry: UMIN000011887. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Comparison of efficacy of transversus abdominis plane block and iliohypogastric/ilioinguinal nerve block for postoperative pain management in patients undergoing inguinal herniorrhaphy with spinal anesthesia: a prospective randomized controlled open-label study.

    PubMed

    Okur, Onur; Tekgul, Zeki Tuncel; Erkan, Nazif

    2017-10-01

    The purpose of this study was to compare the effects of lateral abdominal transversus abdominis plane block (TAP block) and iliohypogastric/ilioinguinal nerve block (IHINB) under ultrasound guidance for postoperative pain management of inguinal hernia repair. Secondary purposes were to compare the complication rates of the two techniques and to examine the effects of TAP block and IHINB on chronic postoperative pain. This was a prospective randomized controlled open-label study. After approval of the Research Ethics Board, a total of 90 patients were allocated to three groups of 30 by simple randomized sampling as determined with a priori power analysis. Peripheral nerve blocks (TAP block or IHINB) were administered to patients following subarachnoid block according to their allocated group. Patient pain scores, additional analgesic requirements and complication rates were recorded periodically and compared. Pain scores were significantly lower in the study groups (p < 0.001, p < 0.001, p < 0.001, p = 0.002, p < 0.001, p < 0.001 for 1, 2, 4, 6, 24, and 48 h and at 1 and 6 months, respectively). First pain declaration times were significantly longer in the study groups (TAP block group [GT] 266.6 ± 119.7 min; IHINB group [GI] 247.2 ± 128.7 min; and control group [GC] 79.1 ± 66.2 min; p < 0.001). At 24 h, the numeric rating scale scores of GT were significantly lower than GI (p = 0.048). Additional analgesic requirements of GT and GI patients were found to be significantly lower than GC patients (p = 0.001, p < 0.001, p = 0.006, p = 0.002, p = 0.001, p < 0.001 for 1, 2, 4, 6, 24, and 48 h, respectively). We conclude that administration of TAP block or IHINB for patients undergoing inguinal herniorrhaphy reduces the intensity of both acute and chronic postoperative pain and additional analgesic requirements.

  20. Bacteria on catheters in patients undergoing peritoneal dialysis.

    PubMed

    Pihl, Maria; Davies, Julia R; Johansson, Ann-Cathrine; Svensäter, Gunnel

    2013-01-01

    Peritonitis is the leading cause of morbidity for peritoneal dialysis (PD) patients, and microbial biofilms have previously been identified on catheters from infected patients. However, few studies of catheters from patients without clinical signs of infection have been undertaken. The aim of the present study was to investigate the extent to which bacteria are present on catheters from PD patients with no symptoms of infection. Microbiologic culturing under aerobic and anaerobic conditions and confocal laser scanning microscopy were used to determine the distribution of bacteria on PD catheters from 15 patients without clinical signs of infection and on catheters from 2 infected patients. The 16S rRNA gene sequencing technique was used to identify cultured bacteria. Bacteria were detected on 12 of the 15 catheters from patients without signs of infection and on the 2 catheters from infected patients. Single-species and mixed-microbial communities containing up to 5 species were present on both the inside and the outside along the whole length of the colonized catheters. The bacterial species most commonly found were the skin commensals Staphylococcus epidermidis and Propionibacterium acnes, followed by S. warneri and S. lugdunensis. The strains of these micro-organisms, particularly those of S. epidermidis, varied in phenotype with respect to their tolerance of the major classes of antibiotics. Bacteria were common on catheters from patients without symptoms of infection. Up to 4 different bacterial species were found in close association and may represent a risk factor for the future development of peritonitis in patients hosting such micro-organisms.

  1. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  2. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  3. 21 CFR 870.1290 - Steerable catheter control system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Steerable catheter control system. 870.1290... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification. A steerable catheter control system is a device that is...

  4. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    PubMed

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  5. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    PubMed

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  6. Catheter placement for lysis of spontaneous intracerebral hematomas: is a navigated stylet better than pointer-guided frameless stereotaxy for intrahematomal catheter positioning?

    PubMed

    Malinova, Vesna; Stockhammer, Florian; Atangana, Etienne Ndzie; Mielke, Dorothee; Rohde, Veit

    2014-06-01

    The optimal management of spontaneous intracerebral hemorrhage (ICH), especially if deep-seated, remains a matter of discussion. Lysis of the blood clot applying recombinant tissue-type plasminogen activator (rtPA) by an intrahematomal catheter is a minimally invasive treatment option, currently being under investigation in a randomized trial. The center position of the catheter in the hematoma is believed to be crucial for an optimal clot lysis. To achieve this objective, frame-based stereotaxy and frameless stereotaxy with guidance of an articulated arm were used. Recently, a preregistered stylet for direct navigation, alleviating the need of guidance, became available. In this study, we evaluated the relative error (RE) describing the deviation of the catheter from the ideal center position in the clot and compared the accuracy of catheter placement using frameless stereotaxy or the novel preregistered stylet. The intrahematomal catheter position was evaluated in three dimensions in 89 patients with spontaneous supratentorial ICH. Frameless stereotaxy with guidance of an articulated arm was performed in 50 patients. The preregistered stylet was used in 39 patients. The catheter position was evaluated using a RE calculating the distance perpendicular to the center of the catheter in relation to the hematoma's diameter. The mean hematoma volume was 51.4 ml. Forty-four out of 89 hematomas were deep-seated. Intraventricular blood was found in 59 patients. The RE of the catheter position was lower in the stylet group in comparison to the frameless stereotaxy group (mean 0.57 vs. 0.90; p = 0.0018). There was no difference between deep-seated and lobar hematomas with regard to the accuracy of catheter placement (p = 0.62). The RE is a robust measure for describing intrahematomal catheter position. The preregistered stylet facilitates a satisfactory catheter placement and is a viable alternative to frameless stereotaxy and guidance with the articulated arm.

  7. [Incidence and risk factors for infections from hemodialysis catheters].

    PubMed

    Jean, G

    2001-01-01

    We report here a revue of hemodialysis catheter-related infections data published since 1985. The reported prevalence of bacteremia is 1 to 20% of catheters, and incidence is 0.72 to 9/1000 catheter-days. Local infection is reported in 6 to 63% of catheters and in 1 to 5/1000 catheter-days. Tunneled catheters and implantables chambers reported less infection rate. The most severe complication is endocarditis (4% rate). Death occurs in 8 to 20% of cases. Reported microbial data show that Staphylococcus aureus (SA) is responsible for most infections ahead of non-aureus Staphylococcus. SA skin colonisation is a risk factor for catheter colonisation and the first step of infection. On the other hand, the host immunity impairment in hemodialysis patients seems a significant risk factor. Iron overload, specially after blood transfusions, older age, diabetes mellitus, low serum albumin level, previous history of bacteremia and immunosuppressive treatment have been frequently involved. Other catheter-related factors are time of use, absence of tunnel and use for parenteral nutrition. Nurses plans, dressing type and frequency, nurses work experience are also important. In spite of recent progress in risk factor understanding, hemodialysis-related infection remains frequent. Multicentre studies are necessary to better evaluated care protocols and new catheter material.

  8. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  9. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  10. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  11. 21 CFR 876.4020 - Fiberoptic light ureteral catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fiberoptic light ureteral catheter. 876.4020... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4020 Fiberoptic light ureteral catheter. (a) Identification. A fiberoptic light ureteral catheter is a device that consists of a...

  12. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner® catheter to deliver stents for anomalous right coronary artery

    PubMed Central

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin. PMID:27489700

  13. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    PubMed

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  14. Biophysics and pathology of catheter energy delivery systems.

    PubMed

    Nath, S; Haines, D E

    1995-01-01

    Catheter ablation has rapidly emerged as the treatment of choice for many symptomatic cardiac arrhythmias. The initial experience with catheter ablation used high-energy DC as the energy source. However, over the last several years radiofrequency (RF) catheter ablation has become the dominant mode of energy delivery. Currently, a major limitation of RF ablation is the small lesion size created by this technique that has reduced its success rate in ablation of larger arrhythmogenic substrates such as coronary artery disease-related ventricular tachycardia. Alternate energy sources such as microwave or ultrasound catheter ablation are being developed that have the potential for producing larger lesions than RF ablation. This review will discuss the biophysics and pathophysiology of the various energy modalities used in catheter ablation.

  15. Pacing threshold changes after transvenous catheter countershock.

    PubMed

    Yee, R; Jones, D L; Klein, G J

    1984-02-01

    The serial changes in pacing threshold and R-wave amplitude were examined after insertion of a countershock catheter in 12 patients referred for management of recurrent ventricular tachyarrhythmias. In 6 patients, values before and immediately after catheter countershock were monitored. Pacing threshold increased (from 1.4 +/- 0.2 to 2.4 +/- 0.5 V, mean +/- standard error of the mean, p less than 0.05) while the R-wave amplitude decreased (bipolar R wave from 5.9 +/- 1.1 to 3.4 +/- 0.7 mV, p less than 0.01; unipolar R wave recorded from the distal ventricular electrode from 8.9 +/- 1.8 to 4.6 +/- 1.2 mV, p less than 0.01; and proximal ventricular electrode from 7.7 +/- 1.5 to 5.0 +/- 1.0 mV, p less than 0.01). A return to control values occurred within 10 minutes. In all patients, pacing threshold increased by 154 +/- 30% (p less than 0.001) during the first 7 days that the catheter was in place. It is concluded that catheter countershock causes an acute increase in pacing threshold and decrease in R-wave amplitude. A catheter used for countershock may not be acceptable as a backup pacing catheter.

  16. [Periinterventional prophylactic antibiotics in radiological port catheter implantation].

    PubMed

    Gebauer, B; Teichgräber, U; Werk, M; Wagner, H-J

    2007-08-01

    To evaluate whether catheter-related infections after radiologically placed port catheters can be reduced by single-shot periinterventional antibiosis. Between January and September 2002, 164 consecutive patients with indication for central venous port catheter implantation were included in the present study. During implantation the interventional radiologist was responsible for deciding whether to administer a prophylactic single-shot antibiosis. The prophylactic antibiosis entailed intravenous administration of ampicillin and sulbactam (3 g Unacid, Pfizer) or 100 mg ciprofloxacine (Ciprobay, Bayer) in the case of an allergy history to penicillins. Catheter-related infection was defined as a local or systemic infection necessitating port catheter extraction. Indication for port catheter implantation was a malignant disease requiring chemotherapy in 158 cases. The port catheter (Chemosite [Tyco Healthcare] [n = 123], low-profile [Arrow International] [n = 35], other port system [n = 6]) was implanted via sonographically guided puncture of the right jugular vein in 139 patients, via the left jugular vein in 24 cases and via the right subclavian vein in one patient. 75 patients received periinterventional prophylactic antibiosis (Unacid [n = 63] Ciprobay [n = 12]) and 89 patients did not receive antibiosis. The prophylactic antibiosis caused a minor allergic reaction in one patient that improved with antihistamic and corticoid medication. A total of 7 ports, 6 without prophylactic antibiosis versus one with periinterventional prophylaxis, were extracted due to infectious complications. Single-shot periinterventional prophylactic antibiosis can reduce early and late infectious complications after radiological-interventional placement of central venous port catheters.

  17. An ovine model of cerebral catheter venography for implantation of an endovascular neural interface.

    PubMed

    Oxley, Thomas James; Opie, Nicholas Lachlan; Rind, Gil Simon; Liyanage, Kishan; John, Sam Emmanuel; Ronayne, Stephen; McDonald, Alan James; Dornom, Anthony; Lovell, Timothy John Haynes; Mitchell, Peter John; Bennett, Iwan; Bauquier, Sebastien; Warne, Leon Norris; Steward, Chris; Grayden, David Bruce; Desmond, Patricia; Davis, Stephen M; O'Brien, Terence John; May, Clive N

    2018-04-01

    OBJECTIVE Neural interface technology may enable the development of novel therapies to treat neurological conditions, including motor prostheses for spinal cord injury. Intracranial neural interfaces currently require a craniotomy to achieve implantation and may result in chronic tissue inflammation. Novel approaches are required that achieve less invasive implantation methods while maintaining high spatial resolution. An endovascular stent electrode array avoids direct brain trauma and is able to record electrocorticography in local cortical tissue from within the venous vasculature. The motor area in sheep runs in a parasagittal plane immediately adjacent to the superior sagittal sinus (SSS). The authors aimed to develop a sheep model of cerebral venography that would enable validation of an endovascular neural interface. METHODS Cerebral catheter venography was performed in 39 consecutive sheep. Contrast-enhanced MRI of the brain was performed on 13 animals. Multiple telescoping coaxial catheter systems were assessed to determine the largest wide-bore delivery catheter that could be delivered into the anterior SSS. Measurements of SSS diameter and distance from the motor area were taken. The location of the motor area was determined in relation to lateral and superior projections of digital subtraction venography images and confirmed on MRI. RESULTS The venous pathway from the common jugular vein (7.4 mm) to the anterior SSS (1.2 mm) was technically challenging to selectively catheterize. The SSS coursed immediately adjacent to the motor cortex (< 1 mm) for a length of 40 mm, or the anterior half of the SSS. Attempted access with 5-Fr and 6-Fr delivery catheters was associated with longer procedure times and higher complication rates. A 4-Fr catheter (internal lumen diameter 1.1 mm) was successful in accessing the SSS in 100% of cases with no associated complications. Complications included procedure-related venous dissection in two major areas: the torcular

  18. 21 CFR 870.1340 - Catheter introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter introducer. 870.1340 Section 870.1340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1340 Catheter introducer...

  19. 21 CFR 870.1250 - Percutaneous catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Percutaneous catheter. 870.1250 Section 870.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1250 Percutaneous catheter...

  20. 21 CFR 870.1250 - Percutaneous catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous catheter. 870.1250 Section 870.1250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1250 Percutaneous catheter...

  1. 21 CFR 870.1340 - Catheter introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter introducer. 870.1340 Section 870.1340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1340 Catheter introducer...

  2. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    PubMed

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  3. Multifunctional Catheters Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    PubMed Central

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Nikoozadeh, Amin; Oralkan, Omer; Khuri-Yakub, Pierre T.; Sahn, David J.

    2015-01-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters’ ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools. PMID:18986948

  4. Fibrinogen release and deposition on urinary catheters placed during urologic procedures

    PubMed Central

    Potretzke, Aaron M.; Schreiber, Henry L.; Park, Alyssa M.; Pinkner, Jerome S.; Caparon, Michael G.; Hultgren, Scott J.; Desai, Alana

    2016-01-01

    Purpose Catheter-associated urinary tract infections (CAUTI) account for ~40% of all hospital-acquired infections worldwide, with more than one million cases diagnosed annually. Recent data from a CAUTI animal model has shown that inflammation induced by catheterization releases host fibrinogen that accumulates on the catheter. Further, Enterococcus faecalis catheter colonization was found to be dependent on EbpA, a fibrinogen binding adhesin. We sought to evaluate this mechanism in a human model. Materials and methods Urinary catheters were collected from human subjects hospitalized for surgical or non-surgical urologic procedures. Catheters were subjected to immunofluorescence analyses by incubating them with anti-fibrinogen antibody and then stained for fluorescence. The fluorescence intensity was compared to standard catheters. Catheters were incubated with strains of Enterococcus faecalis, Staphylococcus aureus, or Candida to assess their binding to fibrinogen-laden catheters. Results Fifty catheters were collected after various surgical and urological procedures. In vivo dwell time ranged from 1 hour to 59 days. All catheters had fibrinogen deposition and its accumulation was dependent on dwell time but not on surgical procedure or catheter material. Catheters were probed ex vivo with E. faecalis, S. aureus, and Candida albicans, which bound to catheters only in those regions where fibrinogen was deposited. Conclusions Taken together, these data show that urinary catheters act as a binding surface for accumulation of fibrinogen, which is released due to inflammation resulting from a urological procedure or from catheter placement, creating a niche that can be exploited by uropathogens to cause CAUTI. PMID:26827873

  5. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-15

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new cathetersmore » following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance

  6. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    PubMed

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  7. 21 CFR 870.1380 - Catheter stylet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter stylet. 870.1380 Section 870.1380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1380 Catheter stylet. (a...

  8. 21 CFR 870.1280 - Steerable catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a...

  9. 21 CFR 870.1300 - Catheter cannula.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter cannula. 870.1300 Section 870.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1300 Catheter cannula. (a...

  10. 21 CFR 870.1380 - Catheter stylet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter stylet. 870.1380 Section 870.1380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1380 Catheter stylet. (a...

  11. 21 CFR 870.1300 - Catheter cannula.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter cannula. 870.1300 Section 870.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1300 Catheter cannula. (a...

  12. 21 CFR 870.1280 - Steerable catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a...

  13. Myositis with antimitochondrial antibodies diagnosed by rectus abdominis muscle biopsy.

    PubMed

    Uenaka, Takeshi; Kowa, Hisatomo; Sekiguchi, Kenji; Nagata, Kakuya; Ohtsuka, Yoshihisa; Kanda, Fumio; Toda, Tatsushi

    2013-05-01

    Antimitochondrial antibodies are autoantibodies detected in 90% of primary biliary cirrhosis (PBC) patients. Some PBC cases are complicated by myositis, which is difficult to confirm due to minimal histological evidence of inflammation in limb muscles. Our aim was to determine the extent of inflammatory changes in a truncal muscle biopsy specimen from a PBC patient. A 48-year-old woman with a 5-year history of atrial fibrillation and chronic heart failure was evaluated for elevated serum creatine kinase level. Antimitochondrial M2 antibodies were detected, and PBC was diagnosed. A biceps brachii biopsy specimen showed mild, non-specific myogenic changes; a second biopsy was performed on the rectus abdominis muscle, which showed typical inflammatory changes. Myositis with antimitochondrial M2 antibodies was confirmed. In myositis patients with antimitochondrial M2 antibodies, muscles of the extremities are involved to a lesser extent. Radiological and histological examination focusing on truncal muscles, including a biopsy, is important. Copyright © 2012 Wiley Periodicals, Inc.

  14. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  15. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  16. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  17. Feedforward responses of transversus abdominis are directionally specific and act asymmetrically: implications for core stability theories.

    PubMed

    Allison, Garry T; Morris, Sue L; Lay, Brendan

    2008-05-01

    Experimental laboratory study supplemented with a repeated case study. To examine bilateral muscle activity of the deep abdominals in response to rapid arm raising, specifically to examine the laterality and directional specificity of feedforward responses of the transversus abdominis (TrA). Based on the feedforward responses of trunk muscles during rapid arm movements, authors have concluded that the deep trunk muscles have different control mechanisms compared to the more superficial muscles. It has been proposed that deep trunk muscles such as TrA contribute substantially to the stability of the lumbar spine and that this is achieved through simultaneous bilateral feedforward activation. These inferences are based on unilateral fine-wire electromyographic (EMG) data and there are limited investigations of bilateral responses of the TrA during unilateral arm raising. Bilateral fine-wire and surface EMG data from the anterior deltoid, TrA, obliquus internus (OI), obliquus externus, biceps femoris, erector spinae, and rectus abdominis during repeated arm raises were recorded at 2 kHz. EMG signal linear envelopes were synchronized to the onset of the anterior deltoid. A feedforward window was defined as the period up to 50 ms after the onset of the anterior deltoid, and paired onsets for bilateral muscles were plotted for both left and right arm movements. Trunk muscles from the group data demonstrated differences between sides (laterality), which were systematically altered when alternate arms were raised (directional specificity). This was clearly evident for the TrA but less obvious for the erector spinae. The ipsilateral biceps femoris and obliquus externus, and contralateral OI and TrA, were activated earlier than the alternate side for both right and left arm movements. This was a consistent pattern over a 7-year period for the case study. Data for the rectus abdominis derived from the case study demonstrated little laterality or directionally specific

  18. 21 CFR 880.5200 - Intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  19. Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.

    PubMed

    Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam

    2006-11-01

    Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.

  20. A magnetic-resonance-imaging-compatible remote catheter navigation system.

    PubMed

    Tavallaei, Mohammad Ali; Thakur, Yogesh; Haider, Syed; Drangova, Maria

    2013-04-01

    A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within the bore of the magnet. While inside the scanner bore, motion accuracy was characterized during the acquisition of frequently used imaging sequences, including real-time gradient echo. The effect of the catheter navigation system on image signal-to-noise ratio (SNR) was also evaluated. The results show that the master-slave system has a maximum time delay of 41 ± 21 ms in replicating motion; an absolute value error of 2 ± 2° was measured for radial catheter motion replication over 360° and 1.0 ± 0.8 mm in axial catheter motion replication over 100 mm of travel. The worst-case SNR drop was observed to be 2.5%.

  1. Factors associated with peritoneal dialysis catheter complications in children.

    PubMed

    Stewart, Camille L; Acker, Shannon N; Pyle, Laura L; Kulungowski, Ann; Cadnapaphornchai, Melissa; Bruny, Jennifer L; Karrer, Frederick

    2016-01-01

    Peritoneal dialysis (PD) is a common method of renal replacement therapy for children. However, placement of PD catheters has risk, and some are never used. We conducted a retrospective chart review of children with a PD catheter placed between 2000 and 2014. Logistic regression analyses were used to identify covariates associated with complications. We identified 175 children with PD catheters. 110 complications developed in 80 children (45.7%). Complications including unexpected return to the operating room and peritonitis increased as the length of time a catheter was in place increased. Children who weighed <12.4 kg had 3.2 times greater odds of developing a leak (95% CI 1.21-8.63, p=0.02). Twelve children never used their PD catheters, 9 with acute kidney injury (AKI) who recovered from their disease more quickly than expected. No covariate was associated with nonuse. Complications with PD catheters are common and increase the longer catheters are in place. Lower weight children are at greater risk of PD catheter leak. Decreased initial volumes of dialysate in smaller children may mitigate this risk. Nonuse may be reduced if dialysis is permitted the day of placement for children with AKI. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Indwelling catheters and medical implants with FXIIIa inhibitors: a novel approach to the treatment of catheter and medical device-related infections

    PubMed Central

    Daneshpour, Nooshin; Collighan, Russell; Perrie, Yvonne; Lambert, Peter; Rathbone, Dan; Lowry, Deborah; Griffin, Martin

    2013-01-01

    Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection and thrombosis (of the catheter or vessel itself) during catheterisation. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalisation and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. PMID:23022540

  3. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  4. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  5. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  6. 21 CFR 870.5150 - Embolectomy catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... thromboemboli, i.e., blood clots which have migrated in blood vessels from one site in the vascular tree to... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Embolectomy catheter. 870.5150 Section 870.5150...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Therapeutic Devices § 870.5150 Embolectomy catheter...

  7. Free tissue transfer of the rectus abdominis myoperitoneal flap for oral reconstruction in a dog.

    PubMed

    Lanz, O I

    2001-12-01

    A five-month-old intact/male Boxer dog was presented 5-days following bite wound trauma to the maxillary region resulting in an oronasal fistula extending from the maxillary canine teeth to the soft palate. Multiple surgical procedures using local, buccal mucosal flaps failed to repair the oronasal fistula. Free tissue transfer of the rectus abdominis myoperitoneal flap using microvascular surgical techniques was successful in providing soft tissue reconstruction of the hard palate area. Complications of these surgical techniques included muscle contraction and subsequent muzzle distortion. Small, refractory oronasal fistulae at the perimeter of the myoperitoneal flap were repaired by primary wound closure.

  8. Use of monorail PTCA balloon catheter for local drug delivery.

    PubMed

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  9. Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.

    PubMed

    Rodrigues, Ana Clara Tude; d'Avila, Andre; Houghtaling, Christopher; Ruskin, Jeremy N; Picard, Michael; Reddy, Vivek Y

    2004-03-01

    Transvascular catheter-based intracardiac echocardiography has been successfully used to help guide catheter ablation and electrophysiologic procedures. It has recently been demonstrated that catheters can be safely placed into the pericardial space to allow for epicardial cardiac mapping and ablation. We evaluated the feasibility of catheter-based intrapericardial echocardiography (IPE) during such procedures to identify cardiac structures and visualize intracardiac catheters. IPE was performed in 7 goats by placing a phased-array ultrasound transducer contained within a 10F steerable catheter into the pericardial space using the same transthoracic subxyphoid approach as used to map and ablate epicardial ventricular tachycardia. Images were obtained of cardiac structures and of intracardiac ablation catheters. After the procedure, the hearts were harvested to assess for possible IPE-related lesions. The IPE catheter could be easily placed inside the pericardial space in all animals. In 7 of 7 cases, longitudinal and short-axis views of right- and left-sided chambers and valves were obtained, similar in orientation to transesophageal echocardiography. Visualization of atrial appendages (6/7), pulmonary veins (6/7), coronary arteries (6/7), and coronary sinus (3/6) was also feasible. Assessment of intracardiac transvalvar and venous blood flow was achieved by spectral and color Doppler. The ablation catheter could be clearly visualized inside cardiac chambers. No arrhythmias were induced with IPE catheter manipulation. After harvesting the hearts, no lesions resulting from the procedure were observed. In this experimental setting, IPE was able to provide detailed images of cardiac structures and establish the relative position of the ablation catheter.

  10. Management of obstructed balloon catheters.

    PubMed Central

    Browning, G G; Barr, L; Horsburgh, A G

    1984-01-01

    Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691

  11. Hemodialysis tunneled central venous catheters: five-year outcome analysis.

    PubMed

    Mandolfo, Salvatore; Acconcia, Pasqualina; Bucci, Raffaella; Corradi, Bruno; Farina, Marco; Rizzo, Maria Antonietta; Stucchi, Andrea

    2014-01-01

    Tunneled central venous catheters (tCVCs) are considered inferior to arteriovenous fistulas (AVFs) and grafts in all nephrology guidelines. However, they are being increasingly used as hemodialysis vascular access. The purpose of this study was to document the natural history of tCVCs and determine the rate and type of catheter replacement. This was a prospective study of 141 patients who underwent hemodialysis with tCVCs between January 2008 and December 2012. The patients used 154 tCVCs. Standard protocols about management of tCVCs, according to European Renal Best Practice, were well established. All catheters were inserted in the internal jugular vein. Criteria for catheter removal were persistent bloodstream infection, detection of an outbreak of catheter-related bloodstream (CRBS) infections, or catheter dysfunction. Event rates were calculated per 1,000 catheter days; tCVC cumulative survival was estimated by Kaplan-Meier analysis. Catheter replacement occurred in 15 patients (0.29 per 1,000 days); catheter dysfunction was the main cause of replacement (0.18 per 1,000 days), typically within 12 months of surgical insertion. A total of 53 CRBS events in 36 patients were identified (0.82 per 1,000 days); 17 organisms, most commonly Gram-positive pathogens, were isolated; 87% of CVC infections were treated by systemic antibiotics associated with lock therapy. tCVC cumulative survival was 91% at 1 year, 88% at 2 years and 85% at 4 years. Our data show a high survival rate of tCVCs in hemodialysis patients, with low incidence of catheter dysfunction and CRBS events. These data justify tCVC use for hemodialysis vascular access, also as first choice, especially in patients with exhausted peripheral access and limited life expectancy.

  12. Antibiofilm surface functionalization of catheters by magnesium fluoride nanoparticles

    PubMed Central

    Lellouche, Jonathan; Friedman, Alexandra; Lahmi, Roxanne; Gedanken, Aharon; Banin, Ehud

    2012-01-01

    The ability of bacteria to colonize catheters is a major cause of infection. In the current study, catheters were surface-modified with MgF2 nanoparticles (NPs) using a sonochemical synthesis protocol described previously. The one-step synthesis and coating procedure yielded a homogenous MgF2 NP layer on both the inside and outside of the catheter, as analyzed by high resolution scanning electron microscopy and energy dispersive spectroscopy. The coating thickness varied from approximately 750 nm to 1000 nm on the inner walls and from approximately 450 nm to approximately 580 nm for the outer wall. The coating consisted of spherical MgF2 NPs with an average diameter of approximately 25 nm. These MgF2 NP-modified catheters were investigated for their ability to restrict bacterial biofilm formation. Two bacterial strains most commonly associated with catheter infections, Escherichia coli and Staphylococcus aureus, were cultured in tryptic soy broth, artificial urine and human plasma on the modified catheters. The MgF2 NP-coated catheters were able to significantly reduce bacterial colonization for a period of 1 week compared to the uncoated control. Finally, the potential cytotoxicity of MgF2 NPs was also evaluated using human and mammalian cell lines and no significant reduction in the mitochondrial metabolism was observed. Taken together, our results indicate that the surface modification of catheters with MgF2 NPs can be effective in preventing bacterial colonization and can provide catheters with long-lasting self-sterilizing properties. PMID:22419866

  13. Positioning of nasobiliary tube using magnet-loaded catheters.

    PubMed

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Mechanical Evaluation of Unobstructing Magnetic Microactuators for Implantable Ventricular Catheters

    PubMed Central

    Lee, Hyowon; Kolahi, Kameran; Bergsneider, Marvin; Judy, Jack W.

    2017-01-01

    Here, we report on the development and evaluation of novel unobstructing magnetic microactuators for maintaining the patency of implantable ventricular catheters used in hydrocephalus application. The treatment of hydrocephalus requires chronic implantation of a shunt system to divert excess cerebrospinal fluid from the brain. These shunt systems suffer from a high failure rate (>40%) within the first year of implantation, often due to biological accumulation. Previously, we have shown that magnetic microactuators can be used to remove biological blockage. The new cantilever-based magnetic microactuator presented in this paper improves upon the previous torsional design using a bimorph to induce a postrelease out-of-plane deflection that will prevent the device from occluding the pore at rest. The mechanical evaluations (i.e., postrelease deflection, static and dynamic responses) of fabricated devices are reported and compared with theoretical values. PMID:29151776

  15. Theory of porous catheters and their applications in intraparenchymal infusions.

    PubMed

    Raghavan, Raghu; Odland, Rick M

    2017-01-01

    Multiport catheters and catheters with a porous surface have been proposed for intraparenchymal infusions of therapeutics in fluid suspensions. Target diseases include brain cancer and serious neurodegenerative diseases, as well as peripheral tumors, for example in the prostate and the liver. We set up the theory for infusions from such devices, in particular the fluid flow equations which demand a coupling between the flow within the catheter and that in tissue. (Such a coupling is not necessary in the theory of infusion from single port catheters.) The new feature of such catheters, treated by our model, is revealed by infusions into inhomogeneous media. Multiport designs have the potential to overcome the limitation of single port catheters, for which the path of the fluid leaving the port is dominated by the inhomogeneities. We solve these equations for some simple cases to illustrate the key design features of porous catheters that show such advantages. The mathematics required for numerical solution with more realistic assumptions is also developed. We confirm the robustness of such catheters, when the ports are sufficiently resistive, against leakage paths that would compromise the infusions from catheters with one or a few large ports. The methods of this paper can be incorporated into a larger planning system for intraparenchymal infusions involving such devices.

  16. Semi-automated location identification of catheters in digital chest radiographs

    NASA Astrophysics Data System (ADS)

    Keller, Brad M.; Reeves, Anthony P.; Cham, Matthew D.; Henschke, Claudia I.; Yankelevitz, David F.

    2007-03-01

    Localization of catheter tips is the most common task in intensive care unit imaging. In this work, catheters appearing in digital chest radiographs acquired by portable chest x-rays were tracked using a semi-automatic method. Due to the fact that catheters are synthetic objects, its profile does not vary drastically over its length. Therefore, we use forward looking registration with normalized cross-correlation in order to take advantage of a priori information of the catheter profile. The registration is accomplished with a two-dimensional template representative of the catheter to be tracked generated using two seed points given by the user. To validate catheter tracking with this method, we look at two metrics: accuracy and precision. The algorithms results are compared to a ground truth established by catheter midlines marked by expert radiologists. Using 12 objects of interest comprised of naso-gastric, endo-tracheal tubes, and chest tubes, and PICC and central venous catheters, we find that our algorithm can fully track 75% of the objects of interest, with a average tracking accuracy and precision of 85.0%, 93.6% respectively using the above metrics. Such a technique would be useful for physicians wishing to verify the positioning of catheter tips using chest radiographs.

  17. Effect of heparin bonding on catheter-induced fibrin formation and platelet activation.

    PubMed

    Nichols, A B; Owen, J; Grossman, B A; Marcella, J J; Fleisher, L N; Lee, M M

    1984-11-01

    Pathologic and experimental evidence indicates that platelet activation and fibrin formation contribute to the pathogenesis of angina pectoris, coronary vasospasm and myocardial infarction. Detection of localized intravascular platelet activation and fibrin formation in vivo by selective blood sampling requires catheters that do not induce coagulation ex vivo. We studied the effect of heparin bonding of catheter surfaces on activation of the coagulation system by cardiovascular catheters. Woven Dacron, polyvinylchloride, and polyurethane catheters were tested and compared with identical catheters with heparin-bonded surfaces in 47 patients undergoing percutaneous cardiac catheterization. Platelet activation was measured by radioimmunoassay of plasma platelet factor 4 (PF4), beta-thromboglobulin (BTG), and thromboxane B2 (TXB2) in blood samples withdrawn through catheters, and fibrin formation was assessed by determination of fibrinopeptide A (FPA) levels. In blood samples collected through conventional catheters, FPA, PF4, BTG, and TXB2 levels were markedly elevated; blood sampling through heparin-bonded catheters had no significant effect on FPA, PF4, BTG, or TXB2 levels. Scanning electron microscopy disclosed extensive platelet aggregates and fibrin strands adherent to the surface of conventional catheters but not to heparin-bonded catheter surfaces. This study demonstrates that (1) collection of blood samples through cardiovascular catheters causes artifactual elevation of FPA, PF4, BTG, and TXB2 levels, and (2) heparin-bonded catheter surfaces effectively prevent catheter-induced platelet alpha-granule release and fibrin formation on catheter surfaces. Heparin-bonded catheters will facilitate investigation of the role of intravascular coagulation in coronary artery disease by eliminating catheter-induced fibrin formation and platelet activation.

  18. Potential in vivo UVC disinfection of catheter lumens: estimation of the doses received by the blood flow outside the catheter tip hole.

    PubMed

    Bak, Jimmy; Jørgensen, Thomas M; Helfmann, Jurgen; Gravemann, Ute; Vorontsova, Inessa

    2011-01-01

    We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2)). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main reason why the UVC exposure to the blood in the catheter application is so low. The very low dose received by the blood through the catheter tip indicated that possible side effects are negligible and makes the UV disinfection technique feasible in a clinical setting. © 2011 Jimmy Bak. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

  19. Urethral catheter insertion forces: a comparison of experience and training.

    PubMed

    Canales, Benjamin K; Weiland, Derek; Reardon, Scott; Monga, Manoj

    2009-01-01

    This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6) had the lowest average insertion force for any group at 6.8 +/- 2.0 Newtons (N). Medical students (n = 10) had the least amount of experience (1 +/- 0 years) and the highest average insertion force range of 10.1 +/- 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 +/- 1.8 N) compared to all groups (p < 0.01). We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.

  20. Videolaparoscopic Catheter Placement Reduces Contraindications to Peritoneal Dialysis

    PubMed Central

    Santarelli, Stefano; Zeiler, Matthias; Monteburini, Tania; Agostinelli, Rosa Maria; Marinelli, Rita; Degano, Giorgio; Ceraudo, Emilio

    2013-01-01

    ♦ Background: Videolaparoscopy is considered the reference method for peritoneal catheter placement in patients with previous abdominal surgery. The placement procedure is usually performed with at least two access sites: one for the catheter and the second for the laparoscope. Here, we describe a new one-port laparoscopic procedure that uses only one abdominal access site in patients not eligible for laparotomic catheter placement. ♦ Method: We carried out one-port laparoscopic placement in 21 patients presenting contraindications to blind surgical procedures because of prior abdominal surgery. This technique consists in the creation of a single mini-laparotomy access through which laparoscopic procedures and placement are performed. The catheter, rectified by an introducer, is inserted inside the port. Subsequently, the port is removed, leaving the catheter in pelvic position. The port is reintroduced laterally to the catheter, confirming or correcting its position. Laparotomic placement was performed in a contemporary group of 32 patients without contraindications to blind placement. Complications and long-term catheter outcome in the two groups were evaluated. ♦ Results: Additional interventions during placement were necessary in 12 patients of the laparoscopy group compared with 5 patients of the laparotomy group (p = 0.002). Laparoscopy documented adhesions in 13 patients, with need for adhesiolysis in 6 patients. Each group had 1 intraoperative complication: leakage in the laparoscopy group, and intestinal perforation in the laparotomy group. During the 2-year follow-up period, laparoscopic revisions had to be performed in 6 patients of the laparoscopy group and in 5 patients of the laparotomy group (p = 0.26). The 1-year catheter survival was similar in both groups. Laparoscopy increased by 40% the number of patients eligible to receive peritoneal dialysis. ♦ Conclusions: Videolaparoscopy placement in patients not eligible for blind surgical

  1. Multicenter Cohort Study to Assess the Impact of a Silver-Alloy and Hydrogel-Coated Urinary Catheter on Symptomatic Catheter-Associated Urinary Tract Infections

    PubMed Central

    Lederer, James W.; Jarvis, William R.; Thomas, Lendon

    2014-01-01

    PURPOSE: The purpose of this study was to determine the effect of a silver-alloy hydrogel catheter on symptomatic catheter-associated urinary tract infections (CAUTIs). DESIGN: Multicenter before-after non-randomized cohort study. SUBJECTS AND SETTING: Seven acute care hospitals ranging in size from 124 to 607 beds participated in this study. The study population included adult patients with a positive urine culture 2 or more days after admission, who underwent Foley catheterization. METHODS: Catheter-associated urinary tract infection surveillance was conducted at each hospital for at least 3 months during the use of a standard catheter and 3 months during the use of the silver-alloy hydrogel catheter. Both the National Healthcare Safety Network (NHSN) surveillance and a clinical definition of CAUTI were used for rate calculation. RESULTS: A 47% relative reduction in the CAUTI rate was observed with the silver-alloy hydrogel catheter compared to the standard catheter when both infection definitions were used (0.945/1000 patient days vs 0.498/1000 patient days) (odds ratio = 0.53; P < .0001; 95% CI: 0.45–0.62). When only NHSN-defined CAUTIs were considered, a 58% relative reduction occurred in the silver-alloy hydrogel period (0.60/1000 patient days vs 0.25/1000 patient days) (odds ratio = 0.42; P < .0001; 95% CI: 0.34–0.53). Antimicrobial days for CAUTIs decreased from 1165 (standard catheter period) to 406 (silver-alloy hydrogel period). CONCLUSIONS: Use of a silver-alloy hydrogel urinary catheter reduced symptomatic CAUTI occurrences as defined by both NHSN and clinical criteria. PMID:24922561

  2. The importance of effective catheter securement.

    PubMed

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  3. Assessment of a new hub design and the semiquantitative catheter culture method using an in vivo experimental model of catheter sepsis.

    PubMed Central

    Segura, M; Alía, C; Valverde, J; Franch, G; Torres Rodríguez, J M; Sitges-Serra, A

    1990-01-01

    An in vivo model of hub-related catheter sepsis in rabbits is reported. The model was used to investigate the protection offered by a new hub design against external contamination by Pseudomonas aeruginosa or Staphylococcus epidermidis and to reassess the diagnostic value of the semiquantitative culture method in bacteremia of endoluminal origin. Contamination of conventional Luer-Lock connectors was followed by clinical sepsis, positive catheter segment cultures, or both, whereas contamination of the new hub was followed by complete protection. Clinical and bacteriological discrepancies observed between contamination with P. aeruginosa and S. epidermidis suggest that the virulence of microorganisms may account for differences in the natural history of hub-originated catheter sepsis. The semiquantitative extraluminal method for catheter culture yielded less than 15 CFU in three animals with proven bacteremia and should not be used as the "gold standard" to define catheter-related bacteremia. PMID:2254430

  4. Catheter fracture of intravenous ports and its management.

    PubMed

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P < 0.05 was considered statistically significant. There were 59 and 1,448 procedures in the fracture and non-fracture groups, respectively. Monovariate analysis revealed that the risk factors for catheter fracture were as follows: large angle (P < 0.0001), female gender (P < 0.0008), subclavian route (P < 0.0001), and port type Arrow French (Fr.) 8.1 (P < 0.0001). Because these risk factors showed no interaction effects, they were all considered independent risk factors. When all factors were considered together, all risk factors, except angle and age, retained their statistical significance. Most catheter fractures were caused by material weakness. If catheter fracture is confirmed, further intervention for port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  5. New materials and devices for preventing catheter-related infections

    PubMed Central

    2011-01-01

    Catheters are the leading source of bloodstream infections for patients in the intensive care unit (ICU). Comprehensive unit-based programs have proven to be effective in decreasing catheter-related bloodstream infections (CR-BSIs). ICU rates of CR-BSI higher than 2 per 1,000 catheter-days are no longer acceptable. The locally adapted list of preventive measures should include skin antisepsis with an alcoholic preparation, maximal barrier precautions, a strict catheter maintenance policy, and removal of unnecessary catheters. The development of new technologies capable of further decreasing the now low CR-BSI rate is a major challenge. Recently, new materials that decrease the risk of skin-to-vein bacterial migration, such as new antiseptic dressings, were extensively tested. Antimicrobial-coated catheters can prevent CR-BSI but have a theoretical risk of selecting resistant bacteria. An antimicrobial or antiseptic lock may prevent bacterial migration from the hub to the bloodstream. This review discusses the available knowledge about these new technologies. PMID:21906266

  6. Development of Active Catheter,Active Guide Wire and Micro Sensor Systems

    PubMed Central

    Haga, Y.; Mineta, T.; Totsu, K.; Makishi, W.; Esashi, M.

    2001-01-01

    Summary Active catheters and active guide wires which move like a snake have been developed for catheter-based minimally invasive diagnosis and therapy. Communication and control IC chips in the active catheter reduce the number of lead wires for control. The active catheter can be not only bent but also torsioned and extended. An ultra minature fiber-optic pressure sensor; a forward-looking ultrasonic probe and a magnetic position and orientation sensor have been developed for catheters and guide wires. These moving mechanisms and several sensors which are fitted near the tip of the catheter and the guide wire will provide detailed information near the tip and enable delicate and effective catheter intervention. PMID:20663389

  7. Effectiveness of dry needling of rectus abdominis trigger points for the treatment of primary dysmenorrhoea: a randomised parallel-group trial.

    PubMed

    Gaubeca-Gilarranz, Alberto; Fernández-de-Las-Peñas, César; Medina-Torres, José Raúl; Seoane-Ruiz, José M; Company-Palonés, Aurelio; Cleland, Joshua A; Arias-Buría, Jose L

    2018-05-02

    To compare the effectiveness of trigger point dry needling (TrP-DN) versus placebo needling, relative to an untreated control group, on pain and quality of life in primary dysmenorrhoea. In this randomised, single blind, parallel-group trial, 56 females with primary dysmenorrhoea were randomly allocated to TrP-DN (n=19), placebo needling (n=18) or no treatment (n=19). Patients in both groups were asked to undertake a stretching exercise of the rectus abdominis daily. The needling group received a single session of TrP-DN to trigger points (TrPs) in the rectus abdominis, and the placebo group received placebo needling. The primary outcome was pain intensity (visual analogue scale). Secondary outcomes were quality of life, use of non-steroidal anti-inflammatory drugs, the number of days with pain, and self-perceived improvement, measured using a Global Rate of Change. Outcomes were assessed at baseline, and 1 and 2 months after the treatment. Females receiving TrP-DN exhibited greater decreases (P<0.001) in pain than those receiving placebo (1 month: Δ-19.8 mm, 25.9 to -13.7; 2 months: Δ-26.0 mm, -33.1 to -18.9) or assigned to the untreated control group (1 month: Δ-26.0mm, -32.5 to -19.5; 2 months: Δ-20.1 mm, -26.4 to -13.8). Females in the TrP-DN group also exhibited a greater decrease in the amount of medications (P<0.001). No differences in the number of days with pain or quality of life were found (all P>0.1). This trial suggests that a single session of TrP-DN of the rectus abdominis combined with stretching was more effective than placebo needling and stretching alone at reducing pain and the amount of medication used in primary dysmenorrhoea. ACTRN12616000170426. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. A qualitative study exploring the value of a catheter passport.

    PubMed

    Jaeger, Melanie De; Fox, Fiona; Cooney, Geraldine; Robinson, Jacqueline

    2017-08-10

    Many patients leaving hospital with a catheter do not have sufficient information to self-care and can experience physical and psychological difficulties. This study aimed to explore how a patient-held catheter passport affects the experiences of patients leaving hospital with a urethral catheter, the hospital nurses who discharge them and the community nurses who provide ongoing care for them. Qualitative methods used included interviews, focus groups and questionnaires, and thematic analysis. Three major themes were reported-informing patients, informing nurses; improving catheter care, promoting self-management; and supporting transition. The catheter passport can bridge the existing information gap, improve care, promote self-care and help patients adjust to their catheter, especially if complemented by ongoing input from a nurse or other health professional.

  9. Remote magnetic navigation for circumferential pulmonary vein ablation: single-catheter technique or additional use of a circular mapping catheter?

    PubMed

    Vollmann, Dirk; Lüthje, Lars; Seegers, Joachim; Sohns, Christian; Sossalla, Samuel; Sohns, Jan; Röver, Christian; Hasenfuß, Gerd; Zabel, Markus

    2014-10-01

    Remote magnetic navigation (RMN) is utilized for catheter guidance during pulmonary vein ablation (PVA). We aimed to determine whether the additional use of a circular mapping catheter (CMC) influences efficacy and outcome of RMN-guided PVA. A total of 80 consecutive subjects (65 % male, age 62 ± 9 years) underwent circumferential PVA with a 3D mapping system and an RMN-guided irrigated catheter. Procedural endpoint was complete PV isolation (PVI), total radiofrequency (RF) time >60 min, or procedure duration >5 h. PVI was defined as an entrance and/or exit block, diagnosed with a CMC within the PV ostium or by pacing via the roving RMN-guided catheter (single-catheter technique). Prolonged Holter monitoring after 3 and 6 months was used to detect atrial tachyarrhythmia (AT/AF) recurrences. Complete PVI was achieved in 56 % (45/80) of all subjects (isolated PVs per patient, 3.1 ± 1.2; RF time, 56.3 ± 17.2 min; procedure duration, 3.8 ± 0.8 h). Prospective validation of the single-catheter technique for diagnosing PVI demonstrated high concordance (94 %) with blinded CMC results. CMC use in first-time PVA was associated with similar total RF and procedure times but higher PV isolation rate. Upon multivariate analysis, CMC use, female gender, left PV, smaller PV ostium and repeat PVA predicted PVI during RMN-guided ablation. Persistent AF and mitral regurgitation at baseline and the number of non-isolated PVs predicted AT/AF recurrence during follow-up. Concomitant CMC use for first-time, RMN-guided PVA is associated with similar procedure duration but higher PV isolation rates as compared to a single-catheter approach. Since the number of isolated PVs predicts freedom from AT/AF, CMC utilization appears advisable for first-time, RMN-guided PVA.

  10. Medical catheters thermally manipulated by fiber optic bundles

    DOEpatents

    Chastagner, Philippe

    1992-01-01

    A maneuverable medical catheter comprising a flexible tube having a functional tip. The catheter is connected to a control source. The functional tip of the catheter carries a plurality of temperature activated elements arranged in parallel and disposed about the functional tip and held in spaced relation at each end. These elements expand when they are heated. A plurality of fiber optic bundles, each bundle having a proximal end attached to the control source and a distal end attached to one of the elements carry light into the elements where the light is absorbed as heat. By varying the optic fiber that is carrying the light and the intensity of the light, the bending of the elements can be controlled and thus the catheter steered. In an alternate embodiment, the catheter carries a medical instrument for gathering a sample of tissue. The instrument may also be deployed and operated by thermal expansion and contraction of its moving parts.

  11. The Development for Polymer Actuator Active Catheter System

    PubMed Central

    Sewa, S.; Onishi, K.; Oguro, K.; Asaka, K.; Taki, W.; Toma, N.

    2001-01-01

    Summary Electric stimuli polymer-metal composite actuator material has been developed for active catheter system and other widely new applications. The polymer actuator is made of ion exchange polymer and gold as electrode, and a pulse voltage of 3 volts on the actuator gave a quick bend 90 degree angle. This composite material is possible to make small size, light and soft actuator. So now we can actually develop an active catheter for the interventional radiology surgery. The prototype polymer actuator active catheter has been developed by using polymer actuator technology and Micro Electronics Mechanical System (MEMS) technologies. The active catheter is controllable from the outside of the body by electric signal. The tip part of the catheter is made of the polymer actuator tube and bends 90 degree angles. The animal tests (dog) showed good actuator performance to control right direction and bending angle at bifurcation of blood vessel and aneurysms. PMID:20663388

  12. Medical catheters thermally manipulated by fiber optic bundles

    DOEpatents

    Chastagner, P.

    1992-10-06

    A maneuverable medical catheter comprising a flexible tube having a functional tip is described. The catheter is connected to a control source. The functional tip of the catheter carries a plurality of temperature activated elements arranged in parallel and disposed about the functional tip and held in spaced relation at each end. These elements expand when they are heated. A plurality of fiber optic bundles, each bundle having a proximal end attached to the control source and a distal end attached to one of the elements carry light into the elements where the light is absorbed as heat. By varying the optic fiber that is carrying the light and the intensity of the light, the bending of the elements can be controlled and thus the catheter steered. In an alternate embodiment, the catheter carries a medical instrument for gathering a sample of tissue. The instrument may also be deployed and operated by thermal expansion and contraction of its moving parts. 10 figs.

  13. Steerable catheter microcoils for interventional MRI reducing resistive heating.

    PubMed

    Bernhardt, Anthony; Wilson, Mark W; Settecase, Fabio; Evans, Leland; Malba, Vincent; Martin, Alastair J; Saeed, Maythem; Roberts, Timothy P L; Arenson, Ronald L; Hetts, Steven W

    2011-03-01

    The aims of this study were to assess resistive heating of microwires used for remote catheter steering in interventional magnetic resonance imaging and to investigate the use of alumina to facilitate heat transfer to saline flowing in the catheter lumen. A microcoil was fabricated using a laser lathe onto polyimide-tipped or alumina-tipped endovascular catheters. In vitro testing was performed on a 1.5-T magnetic resonance system using a vessel phantom, body radiofrequency coil, and steady-state pulse sequence. Resistive heating was measured with water flowing over a polyimide-tip catheter or saline flowing through the lumen of an alumina-tip catheter. Preliminary in vivo testing in porcine common carotid arteries was conducted with normal blood flow or after arterial ligation when current was applied to an alumina-tip catheter for up to 5 minutes. After application of up to 1 W of direct current power, clinically significant temperature increases were noted with the polyimide-tip catheter: 23°C/W at zero flow, 13°C/W at 0.28 cm(3)/s, and 7.9°C/W at 1 cm(3)/s. Using the alumina-tip catheter, the effluent temperature rise using the lowest flow rate (0.12 cm(3)/s) was 2.3°C/W. In vivo testing demonstrated no thermal injury to vessel walls at normal and zero arterial flow. Resistive heating in current carrying wire pairs can be dissipated by saline coolant flowing within the lumen of a catheter tip composed of material that facilitates heat transfer. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  14. Thromboresistance Characterization of Extruded Nitric Oxide-Releasing Silicone Catheters

    PubMed Central

    Amoako, Kagya A.; Archangeli, Christopher; Handa, Hitesh; Major, Terry; Meyerhoff, Mark E.; Annich, Gail M.; Bartlett, Robert H.

    2013-01-01

    Intravascular catheters used in clinical practice can activate platelets, leading to thrombus formation and stagnation of blood flow. Nitric oxide (NO)-releasing polymers have been shown previously to reduce clot formation on a number of blood contacting devices. In this work, trilaminar NO-releasing silicone catheters were fabricated and tested for their thrombogenicity. All catheters had specifications of L = 6 cm, inner diameter = 21 gauge (0.0723 cm), outer diameter = 12 gauge (0.2052 cm), and NO-releasing layer thickness = 200 ± 11 μm. Control and NO-releasing catheters were characterized in vitro for their NO flux and NO release duration by gas phase chemiluminescence measurements. The catheters were then implanted in the right and left internal jugular veins of (N = 6 and average weight = 3 kg) adult male rabbits for 4 hours thrombogenicity testing. Platelet counts and function, methemoglobin (metHb), hemoglobin (Hb), and white cell counts and functional time (defined as patency time of catheter) were monitored as measured outcomes. Nitric oxide-releasing catheters (N = 6) maintained an average flux above (2 ± 0.5) × 10−10 mol/min/cm2 for more than 24 hours, whereas controls showed no NO release. Methemoglobin, Hb, white cell, and platelet counts and platelet function at 4 hours were not significantly different from baseline (α = 0.05). However, clots on controls were visibly larger and prevented blood draws at a significantly (p < 0.05) earlier time (2.3 ± 0.7 hours) into the experiment, whereas all NO-releasing catheters survived the entire 4 hours test period. Results indicate that catheter NO flux levels attenuated thrombus formation in a short-term animal model. PMID:22395119

  15. Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

    PubMed

    Cheng, Weyland; Law, Peter K

    2017-08-01

    Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.

  16. The effects of electric current on bacteria colonising intravenous catheters.

    PubMed

    Liu, W K; Tebbs, S E; Byrne, P O; Elliott, T S

    1993-11-01

    The effect of a direct electric current (10 microA) on the growth of Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Klebsiella pneumoniae and Proteus mirabilis was investigated. When the ends of negatively-charged intravascular catheters were placed in nutrient agar seeded with bacteria, circular zones of inhibition of bacterial growth were observed around the catheters. The zones ranged from 6 to 16 mm in diameter according to the organism under test. Zones of inhibition were not produced around positively-charged catheters. Bacteria colonising the surfaces of catheters were similarly affected by the application of a 10 microA electric current. A negative electric current applied to colonised catheters for 4 to 24 h significantly reduced the number of adherent viable organisms as compared to controls. The results demonstrated that a constant electric current of low amperage might be used to reduce bacterial colonisation of intravascular catheters. This may offer a novel means of protecting catheters and other prosthetic devices from associated sepsis in vivo.

  17. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    PubMed

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Candida tropicalis biofilms: artificial urine, urinary catheters and flow model.

    PubMed

    Negri, Melyssa; Silva, Sónia; Henriques, Mariana; Azeredo, Joana; Svidzinski, Terezinha; Oliveira, Rosário

    2011-10-01

    Adhesion to medical devices and biofilm formation are considered important virulence factors of Candida tropicalis. This work aimed to use artificial urine (AU) and urinary catheters, under flow conditions, for studying C. tropicalis biofilms. Adhesion and biofilm formation on silicone and latex urinary catheters were quantified by crystal violet staining and determination of colony forming units. Candida surface hydrophobicity was also evaluated, as well as the biofilms' matrix content in terms of proteins and carbohydrates. Candida tropicalis was able to adhere and to form biofilms along the entire length of the catheters under flow conditions. It was found that the isolate U69 adhered significantly more to both types of catheters than did the reference strain. However, U69 biofilms contained significantly less cultivable cells and higher biofilm biomass than those of the reference strain. Detachment of cells from biofilms on latex catheter was lower compared to silicone catheter. This model using AU appeared to be suitable for studies mimicking the real body conditions. Additionally, C. tropicalis was in fact able to colonize urinary catheters in the presence of AU and to detach from these catheters, demonstrating their capacity to colonize distal sites.

  19. Choline deficiency is associated with increased risk for venous catheter thrombosis.

    PubMed

    Buchman, Alan L; Ament, Marvin E; Jenden, Donald J; Ahn, Chul

    2006-01-01

    Patients with intestinal failure who require long-term parenteral nutrition (PN) develop catheter thrombosis as a complication. This patient group may also develop choline deficiency because of a defect in the hepatic transsulfuration pathway in the setting of malabsorption. This study was undertaken to determine whether choline deficiency is a risk factor for development of catheter thrombosis. Plasma free and phospholipid-bound choline concentrations were measured in a group of 41 patients that required long-term PN. Episodes of catheter thrombosis from onset of PN to the time of blood testing were recorded. Sixteen (39%) patients developed catheter thrombosis, and 5 of these had recurrent catheter thrombosis. Plasma free choline was 7.7 +/- 2.7 nmol/mL in patients with no history of catheter thrombosis and 6.2 +/- 1.7 nmol/mL in patients with previous catheter thrombosis (p = .076 by Wilcoxon rank-sum test). The partial correlation between plasma free choline concentration and the frequency of clots after controlling for catheter duration was r = -0.33 (p = .038). The relative risk for catheter thrombosis in subjects with a plasma free choline concentration <8 nmol/mL was 10.0, 95% confidence interval (1.134-88.167). Plasma phospholipid-bound choline concentration was 2191.7 +/- 679.0 nmol/mL in patients with previous catheter thrombosis and 2103.3 +/- 531.2 nmol/mL in patients without history of catheter thrombosis (p = NS). Choline deficiency is a significant risk factor for development of catheter thrombosis in patients with intestinal failure who require PN.

  20. Central venous catheter-related bloodstream infections in the intensive care unit

    PubMed Central

    Patil, Harsha V.; Patil, Virendra C.; Ramteerthkar, M. N.; Kulkarni, R. D.

    2011-01-01

    Context: Central venous catheter-related bloodstream infection (CRBSI) is associated with high rates of morbidity and mortality in critically ill patients. Aims: This study was conducted to determine the incidence of central venous catheter-related infections (CRIs) and to identify the factors influencing it. So far, there are very few studies that have been conducted on CRBSI in the intensive care unit in India. Settings and Design: This was a prospective, observational study carried out in the medical intensive care unit (MICU) over a period of 1 year from January to December 2004. Materials and Methods: A total of 54 patients with indwelling central venous catheters of age group between 20 and 75 years were included. The catheters were cultured using the standard semiquantitative culture (SQC) method. Statistical analysis used SPSS-10 version statistical software. Results: A total of 54 CVC catheters with 319 catheter days were included in this study. Of 54 patients with CVCs studied for bacteriology, 39 (72.22%) catheters showed negative SQCs and also negative blood cultures. A total of 15 (27.77%) catheters were positive on SQC, of which 10 (18.52%) were with catheter-associated infection and four (7.41%) were with catheter-associated bacteremia; the remaining one was a probable catheter-associated bacteremia. CRIs were high among catheters that were kept in situ for more than 3 days and emergency procedures where two or more attempts were required for catheterization (P < 0.05). In multivariate analysis of covariance duration of catheter in situ for >3 days, inexperienced venupucturist, more number of attempts and emergency CVC were associated with more incidence of CVCBSIs, with P <0.02. The duration of catheter in situ was negatively correlated (-0.53) and number of attempts required to put CVC was positively correlated (+0.39) with incidence of CVCBSIs. Sixty-five percent of the isolates belonged to the CONS group (13/20). Staphylococcus epidermidis showed

  1. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    PubMed

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  2. Catheter-related sepsis due to Rhodotorula glutinis.

    PubMed

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-02-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 microg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns.

  3. Catheter-Related Sepsis Due to Rhodotorula glutinis

    PubMed Central

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  4. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    PubMed

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  5. Number and location of drainage catheter side holes: in vitro evaluation.

    PubMed

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Diagnostic procedures for catheter malfunction in programmable implantable intraperitoneal insulin infusion devices.

    PubMed

    Olsen, C L; Turner, D S; Iravani, M; Waxman, K; Selam, J L; Charles, M A

    1995-01-01

    To evaluate the roles of 1) abdominal radiography, 2) a pressure diagnostic procedure (PDP) using a standardized diluent infusion into the catheter sideport, and 3) radiocontrast imaging of the catheter lumen as procedures for diagnosing catheter malfunction in diabetic patients implanted with a programmable intraperitoneal infusion device. Sixteen type I diabetic patients implanted with Infusaid programmable intraperitoneal insulin pumps were studied. The ability of the above three procedures to assist diagnosis of catheter malfunction and distinguish between occlusion and catheter breakage was retrospectively analyzed. Glycated hemoglobin was measured to determine the clinical importance of catheter malfunctions and decreases in pump flow due to insulin aggregation in the pump chamber. Mean glycated hemoglobin levels increased significantly from 8.0 +/- 0.3 to 9.0 +/- 0.4% (P < 0.05) before and after catheter malfunction, but not during pump flow slowdowns. Mean peak pressure during PDP was 1.96 +/- 0.14 psi (P < 0.01 vs. normal) in reversibly occluded catheters and 1.86 +/- 0.35 psi (P < 0.05 vs. normal) in broken catheters, compared with 1.32 +/- 0.23 psi in normal catheters. Decay times during PDP were > 50 s for both reversibly occluded and broken catheters (P < 0.001 vs. normal of 3.6 +/- 0.82 s). Abdominal radiographs and sideport injections of contrast material were used to distinguish the types of broken catheters. Catheter breakage and occlusion are complications in implantable insulin infusion systems and result in metabolic deterioration. The presence of a sideport allows pressure data and radiographic procedures to assist in determining the cause of catheter malfunction. A diagnostic algorithm was generated to improve efficiency in investigating catheter problems.

  7. Suprapubic catheter care

    MedlinePlus

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  8. Evaluation of robotic endovascular catheters for arch vessel cannulation.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Hamady, Mohamad S; Cheshire, Nicholas J W

    2011-09-01

    Conventional catheter instability and embolization risk limits the adoption of endovascular therapy in patients with challenging arch anatomy. This study investigated whether arch vessel cannulation can be enhanced by a remotely steerable robotic catheter system. Seventeen clinicians with varying endovascular experience cannulated all arch vessels within two computed tomography-reconstructed pulsatile flow phantoms (bovine type I and type III aortic arches), under fluoroscopic guidance, using conventional and robotic techniques. Quantitative (catheterization times, catheter tip movements, vessel wall hits, catheter deflection) and qualitative metrics (Imperial College Complex Endovascular Cannulation Scoring Tool [IC3ST]) performance scores were compared. Robotic catheterization techniques resulted in a significant reduction in median carotid artery cannulation times and the median number of catheter tip movements for all vessels. Vessel wall contact with the aortic arch wall was reduced to a median of zero with robotic catheters. During stiff guidewire exchanges, robotic catheters maintained stability with zero deflection, independent of the distance the catheter was introduced into the carotid vessels. Overall IC3ST performance scores (interquartile range) were significantly improved using the robotic system: Type I arch score was 26/35 (20-30.8) vs 33/35 (31-34; P = .001), and type III arch score was 20.5/35 (16.5-28.5) vs 26.5/35 (23.5-28.8; P = .001). Low- and medium-volume interventionalists demonstrated an improvement in performance with robotic cannulation techniques. The high-volume intervention group did not show statistically significant improvement, but cannulation times, movements, and vessel wall hits were significantly reduced. Robotic technology has the potential to reduce the time, risk of embolization and catheter dislodgement, radiation exposure, and the manual skill required for carotid and arch vessel cannulation, while improving overall

  9. Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.

    PubMed

    Capone, Christine A; Ceresnak, Scott R; Nappo, Lynn; Gates, Gregory J; Schechter, Clyde B; Pass, Robert H

    2015-12-01

    To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs). A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups. Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time. Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach. © 2015 Wiley Periodicals, Inc.

  10. The effects of bridge exercise on an unstable base of support on lumbar stability and the thickness of the transversus abdominis.

    PubMed

    Cho, Misuk; Jeon, Hyewon

    2013-06-01

    [Purpose] We examined the effects of an abdominal drawing-in bridge exercise using a pressure biofeedback unit on different bases on the thickness of trunk and abdominal muscles, and lumbar stability. [Subjects] Thirty healthy young adults (2 males, 28 females) took part in this study. The subjects were randomly and equally assigned to a stable bridge exercise group and an unstable bridge exercise group. [Methods] The subjects performed bridge exercises using an abdominal drawing-in method on a stable base and on an unstable base, and changes in their abdominal muscle thickness and on the stable and on unstable bases lumbar stability were evaluated. [Results] After the intervention, the stable bridge exercise group showed a statistically significantly increased muscle thickness in the transversus abdominis, and the unstable bridge exercise group showed significantly increased muscle thicknesses of the transversus abdominis and internal obliques in static and dynamic lumbar stability. The unstable bridge exercise group showed significant increase after performing the exercise. [Conclusion] Lumbar stability exercise, with the compensation of the lumbar spine minimized, using an abdominal drawing-in method on an unstable support of base is effective and efforts to prevent the compensation may induce a greater exercise effect.

  11. Catheter-associated UTI

    MedlinePlus

    ... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  12. A computational fluid dynamics simulation framework for ventricular catheter design optimization.

    PubMed

    Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A

    2017-11-10

    OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using

  13. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    PubMed

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  14. 21 CFR 870.1240 - Flow-directed catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Flow-directed catheter. 870.1240 Section 870.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1240 Flow-directed catheter...

  15. 21 CFR 870.1370 - Catheter tip occluder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...

  16. 21 CFR 870.1370 - Catheter tip occluder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...

  17. 21 CFR 870.1240 - Flow-directed catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flow-directed catheter. 870.1240 Section 870.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1240 Flow-directed catheter...

  18. The effect of bridge exercise method on the strength of rectus abdominis muscle and the muscle activity of paraspinal muscles while doing treadmill walking with high heels.

    PubMed

    Kang, Taewook; Lee, Jaeseok; Seo, Junghoon; Han, Dongwook

    2017-04-01

    [Purpose] The purpose of this research is to investigate the effect of the method of bridge exercise on the change of rectus abdominis muscle and the muscle activity of paraspinal muscles while doing treadmill walking with high heels. [Subjects and Methods] The subjects of this research are healthy female students consisting of 10 persons performing bridge exercises in a supine group, 10 persons performing bridge exercises in a prone group, and 10 persons in a control group while in S university in Busan. Bridge exercise in supine position is performed in hook lying position. Bridge exercise in prone position is plank exercise in prostrate position. To measure the strength of rectus abdominis muscle, maintaining times of the posture was used. To measure the muscle activity of paraspinal muscles, EMG (4D-MT & EMD-11, Relive, Korea) was used. [Results] The strength of rectus abdominis muscle of both bridge exercises in the supine group and bridge exercises in the prone group increases significantly after exercise. The muscle activity of paraspinal muscle such as thoracic parts and lumbar parts in bridge exercises in the prone group decreases statistically while walking on a treadmill with high heels. Muscle activity of thoracic parts paraspinal muscle and bridge exercises in the supine group decreased significantly. [Conclusion] According to this study, we noticed that bridge exercise in a prone position is desirable for women who prefer wearing high heels as a back pain prevention exercise method.

  19. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    PubMed

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  20. Investigations of the pushability behavior of cardiovascular angiographic catheters.

    PubMed

    Bloss, Peter; Rothe, Wolfgang; Wünsche, Peter; Werner, Christian; Rothe, Alexander; Kneissl, Georg Dieter; Burger, Wolfram; Rehberg, Elisabeth

    2003-01-01

    The placement of angiographic catheters into the vascular system is a routine procedure in modern clinical business. The definition of objective but not yet available evaluation protocols based on measurable physical quantities correlated to the empirical clinical findings is of utmost importance for catheter manufacturers for in-house product screening and optimization. In this context, we present an assessment of multiple mechanical and surface catheter properties such as static and kinetic friction, bending stiffness, microscopic surface topology, surface roughness, surface free energy and their interrelation. Theoretical framework, description of experimental methods and extensive data measured on several different catheters are provided and in conclusion a testing procedure is defined. Although this procedure is based on the measurement of several physical quantities it can be easily implemented by commercial laboratories testing catheters as it is based on relatively low-cost standard methods.

  1. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    PubMed

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  2. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    PubMed

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  3. Catheter-associated urinary tract infections and other infections in patients hospitalized for acute stroke: A prospective cohort study of two different silicone catheters.

    PubMed

    Stenzelius, Karin; Laszlo, Liselott; Madeja, Magdalena; Pessah-Rasmusson, Hélène; Grabe, Magnus

    2016-12-01

    Catheter-associated urinary tract infection (CAUTI) is the most common healthcare-associated infection. The primary aim of this study was to investigate whether the use of a silicone catheter coated with an ultrathin layer of a combination of the noble metals gold, palladium and silver (BIP™-silicone catheter) could reduce the incidence of CAUTI and antibiotic prescription compared with a standard silicone catheter in a cohort of acute neurological patients suffering primarily from stroke. At the same time, all infectious events requiring prescription of an antimicrobial agent were registered and are reported. The study was designed as a crossover cohort study enrolling men and women aged over 18 years, requiring emergency management for stroke including the insertion of an indwelling catheter. Data on patient characteristics, urinary tract infections (UTIs), other infectious events and all antibiotic prescriptions were recorded prospectively. The patients' characteristics differed in the two centres in terms of age but not in diagnosis distribution. UTIs were recorded in 78 (24.2%) of the patients, ahead of pulmonary tract infections (n = 65; 20.2%). There was no difference in terms of CAUTI in the two catheter groups, even in subgroups with catheter treatment for 1 week or less. The patients with a diagnosed UTI required 3.5 more days of hospitalization than those without a UTI. CAUTIs were the most frequent healthcare-associated infections, slightly ahead of pulmonary tract infections. No advantages of the coated catheter could be found in this cohort of critically ill patients.

  4. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    PubMed Central

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  5. Risk factor analysis for long-term tunneled dialysis catheter-related bacteremias.

    PubMed

    Jean, G; Charra, B; Chazot, C; Vanel, T; Terrat, J C; Hurot, J M; Laurent, G

    2002-07-01

    Infection, mainly related to vascular access, is one of the main causes of morbidity and a preventable cause of death in hemodialysis patients. From January 1994 to April 1998 we conducted a prospective study to assess the incidence and risk factors of catheter-related bacteremia. One hundred and twenty-nine tunneled dual-lumen hemodialysis catheters were inserted percutaneously into the internal jugular vein in 89 patients. Bacteremia (n = 56) occurred at least once with 37 (29%) of the catheters (an incidence of 1.1/1,000 catheter-days); local infection (n = 45, 1/1,000 catheter-days) was associated with bacteremia in 18 cases. Death in 1 case was directly related to Staphylococcus aureus (SA) septic shock, and septicemia contributed to deaths in 2 additional cases. Catheters were removed in 48% of the bacteremic episodes. Treatment comprised intravenous double antimicrobial therapy for 15-20 days. Bacteriological data of bacteremia showed 55% involvement of SA. Nasal carriage of SA was observed in 35% of the patients with catheters. Bacteremic catheters were more frequently observed in patients with diabetes mellitus (p = 0.03), peripheral atherosclerosis (p = 0.001), a previous history of bacteremia (p = 0.05), nasal carriage of SA (p = 0.0001), longer catheter survival time (p = 0.001), higher total intravenous iron dose (p = 0.001), more frequent urokinase catheter infusion (p < 0.01), and local infection (p < 0.001) compared with non-bacteremic catheters. Monovariate survival analysis showed that significant initial risk factors for bacteremia were nasal carriage of SA (p = 0.00001), previous bacteremia (p = 0.0001), peripheral atherosclerosis (p = 0.005), and diabetes (p = 0.04). This study confirms the relatively high incidence of bacteremia with tunneled double-lumen silicone catheters and its potential complications. Possible preventive actions are discussed according to the risk factors. Copyright 2002 S. Karger AG, Basel

  6. Cryo-balloon catheter position planning using AFiT

    NASA Astrophysics Data System (ADS)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  7. A prospective randomized trial comparing Foley catheter, oxytocin, and combination Foley catheter-oxytocin for labour induction with unfavourable cervix.

    PubMed

    El Khouly, Nabih I

    2017-04-01

    The purpose of this study was to evaluate the effectiveness and safety of transcervical Foley catheter with and without oxytocin versus oxytocin alone for labour induction with unfavourable cervix. This trial enrolled 108 women with singleton pregnancies presented for labour induction with unfavourable cervix. Patients were randomly assigned to receive Foley catheter alone (I), Foley catheter plus oxytocin (II) or oxytocin alone (III). Outcomes were analysed in terms of success of induction, induction delivery interval, route of delivery, dose and duration of oxytocin, and complications. Successful normal vaginal delivery was more common in group I (p = .02) compared to group III. Induction delivery time was statistically shorter in group II and group III (p < .001). Patients in group I required significantly less oxytocin dose and duration (p < .001). This led to our conclusion that induction of labour with Foley catheter without oxytocin increases success rate of normal vaginal delivery; however, it has a longer induction delivery interval with similar complications.

  8. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    PubMed

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  9. High definition urethral pressure profilometry: Evaluating a novel microtip catheter.

    PubMed

    Klünder, Mario; Amend, Bastian; Vaegler, Martin; Kelp, Alexandra; Feuer, Ronny; Sievert, Karl-Dietrich; Stenzl, Arnulf; Sawodny, Oliver; Ederer, Michael

    2016-11-01

    Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI). SUI is a significant medical, social, and economic problem, affecting about 12.5% of the population. A novel microtip catheter was developed for UPP featuring an inclination sensor and higher angular resolution compared to systems in clinical use today. Therewith, the location of each measured pressure sample can be determined and the spatial pressure distribution inside the urethra reconstructed. In order to assess the performance and plausibility of data from the microtip catheter, we compare it to data from a double balloon air charged system. Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, plotted and compared against data from the air-charged catheter. The microtip catheter delivers results in agreement with previous comparisons of microtip and air-charged systems. It additionally provides a new level of detail in the reconstructed UPPs which may lead to new insights into the sphincter mechanism of minipigs. The ability of air-charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novel microtip catheter in combination with a signal reconstruction algorithm delivers plausible data. It offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct location within the anatomical location of the pelvic floor. Neurourol. Urodynam. 35:888-894, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  10. The effect of elastic modulus on ablation catheter contact area.

    PubMed

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  11. Long-Term Outcomes of Single-Port Laparoscopic Placement of Peritoneal Dialysis Catheter.

    PubMed

    Pan, Alan; Poi, Mun J; Matos, Jesus; Jiang, Jenny S; Kfoury, Elias; Echeverria, Angela; Bechara, Carlos F; Lin, Peter H

    2016-07-01

    Laparoscopic insertion of peritoneal dialysis (PD) catheter has become a preferred method compared to the traditional open technique for PD catheter insertion. We retrospectively report the outcome of 1-port laparoscopic placement PD catheters in our institution. A total of 263 patients with end-stage renal disease who underwent single-trocar laparoscopic PD catheter insertion during a recent 6-year period were reviewed. Laparoscopic technique involves introducing a PD catheter over a stiff guidewire into the abdominal cavity through a 10-mm laparoscopic port. Pertinent clinical variables, procedural complications, and follow-up outcome were analyzed. There were 182 men and 81 women. The mean age was 56 years. Technical success was 95.8%. Catheter occlusion was the most common early complications (<6 months) that occurred in 4 (1.5%) patients. Late complications (> 6 months) including catheter occlusion, cuff extrusion, catheter leakage, catheter migration, infection, and hernia occurred in 5 patients (1.9%), 2 patients (0.8%), 3 patients (1.1%), 3 patients (1.1%), 6 patients (2.3%), and 4 patients (1.5), respectively. Mean follow-up time was 39 ± 18 months. Catheter survival rate at 1, 2, 3, 4, and 5 years was 96%, 94%, 90%, 85%, and 82%, respectively. Laparoscopic PD catheter implantation via a single-trocar utilizing a stiff guidewire technique is feasible and safe. This method can result in low complication and high catheter survival rate. © The Author(s) 2016.

  12. Modified laparoscopic placement of peritoneal dialysis catheter with intra-abdominal fixation.

    PubMed

    Shen, Quanquan; Jiang, Xinxin; Shen, Xiaogang; Yu, Fangyan; Tu, Qiudi; Chen, Wangfang; Ye, Qing; Behera, Tapas Ranjan; He, Qiang

    2017-08-01

    Peritoneal dialysis (PD) is a commonly accepted method of treating end-stage renal disease (ESRD). Various laparoscopic techniques for the placement of PD catheter have been described. In this study, we developed a novel modified laparoscopic technique for PD catheter placement and evaluated the early results. A straight Tenckhoff PD catheter was placed employing the modified technique in 39 consecutive patients with ESRD from May 2013 to April 2016. The technique is laparoscopically guided intra-abdominal fixation of the PD catheter tip at one point by using suture passer hernia forceps. Individual information including sex, age, primary disease etiology, complications, surgical duration, morbidity, mortality and catheter survival was collected and analyzed. The modified laparoscopic procedure was effectively performed in all patients with a mean operative time of 45 ± 7 min. No conversions from laparoscopy to open surgery of catheter placement occurred. There was one case showing early pericatheter leakage. There were no serious complications, such as bleeding, abdominal wall hernias, distal catheter cuff extrusion and infections of the exit site or tunnel during surgery or the postoperative duration. No mortality was observed in this group of patients. The 6-month follow-up study showed 100% catheter-related complication-free survival. Our modified laparoscopic intra-abdominal fixation technique using suture passer hernia forceps is a simple and safe method for PD catheter placement and is effective in minimizing the risk of catheter migration.

  13. [Disposable nursing applicator-pocket of indwelling central venous catheter].

    PubMed

    Wei, Congli; Ma, Chunyuan

    2017-11-01

    Catheter related infection is the most common complication of central venous catheter, which pathogen mainly originate from the pipe joint and the skin around puncture site. How to prevent catheter infection is an important issue in clinical nursing. The utility model disclosed a "disposable nursing applicator-pocket of indwelling central venous catheter", which is mainly used for the fixation and the protection. The main structure consists of two parts, one is medical applicator to protect the skin around puncture site, and the other is gauze pocket to protect the catheter external connector. When in use, the catheter connector is fitted into the pocket, and then the applicator is applied to cover the puncture point of the skin. Integrated design of medical applicator and gauze pocket was designed to realize double functions of fixation and protection. The disposable nursing applicator-pocket is made of medical absorbent gauze (outer layer) and non-woven fabric (inner layer), which has the characteristics of comfortable, breathable, dust filtered, bacteria filtered, waterproof, antiperspirant and anti-pollution. The utility model has the advantages of simple structure, low cost, simple operation, effective protection, easy realization and popularization.

  14. Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters

    PubMed Central

    Fujimoto, Kazuteru; Miyao, Yuji

    2014-01-01

    Introduction Recent studies have reported the efficacy of sheathless percutaneous coronary intervention (PCI) using hydrophilic-coated 5-Fr guiding catheters that are one to two Fr sizes smaller in diameter than the corresponding introducer sheath (virtual 3-Fr PCI). However, the limited number of shapes of hydrophilic-coated guiding catheters occasionally makes them difficult to engage and control. Aim To evaluate the efficacy and feasibility of virtual 3-Fr PCI using standard guiding catheters of various shapes. Material and methods We identified 35 consecutive patients with stable angina, who underwent virtual 3-Fr PCI using either hydrophilic-coated guiding catheters (Works™, Medikit, Japan) or standard guiding catheters (Heartrail™, Terumo, Japan). Results Thirty-five patients were identified (63% men; mean age 70 ±13 years). In 2 cases, hydrophilic-coated guiding catheters were exchanged to standard guiding catheters because of difficulty in engaging the target coronary arteries. Ultimately, standard guiding catheters were used in 20 patients (57%) and hydrophilic-coated catheters were used in 15 (43%). One of 20 patients treated with standard guiding catheters and 1 of 15 treated with hydrophilic-coated guiding catheters underwent the 4-in-3 “slender mother and child” PCI technique due to difficulty of stent deployment. There were no differences between the two groups in PCI procedural variables such as procedural time, fluoroscopy time, radiation dose, or contrast dye volume. There were no access site-related complications in this study. Conclusions These findings indicate that virtual 3-Fr PCI using standard guiding catheters is as efficient and safe as virtual 3-Fr PCI using hydrophilic-coated guiding catheters. PMID:25489315

  15. A novel four-wire-driven robotic catheter for radio-frequency ablation treatment.

    PubMed

    Yoshimitsu, Kitaro; Kato, Takahisa; Song, Sang-Eun; Hata, Nobuhiko

    2014-09-01

       Robotic catheters have been proposed to increase the efficacy and safety of the radio-frequency ablation treatment. The robotized motion of current robotic catheters mimics the motion of manual ones-namely, deflection in one direction and rotation around the catheter. With the expectation that the higher dexterity may achieve further efficacy and safety of the robotically driven treatment, we prototyped a four-wire-driven robotic catheter with the ability to deflect in two- degree-of-freedom motions in addition to rotation.    A novel quad-directional structure with two wires was designed and developed to attain yaw and pitch motion in the robotic catheter. We performed a mechanical evaluation of the bendability and maneuverability of the robotic catheter and compared it with current manual catheters.    We found that the four-wire-driven robotic catheter can achieve a pitching angle of 184.7[Formula: see text] at a pulling distance of wire for 11 mm, while the yawing angle was 170.4[Formula: see text] at 11 mm. The robotic catheter could attain the simultaneous two- degree-of-freedom motions in a simulated cardiac chamber.    The results indicate that the four-wire-driven robotic catheter may offer physicians the opportunity to intuitively control a catheter and smoothly approach the focus position that they aim to ablate.

  16. Knowledge of nursing students about central venous catheters.

    PubMed

    Mlinar, Suzana; Malnarsić, Rosanda Rasković

    2012-04-01

    Central venous catheters (CVC) are at the crucial importance, particulary in the intensive therapy units. In order to handle a CVC safely, nursing students need to acquire theoretical and practical knowledge during the course of their studies. The aim of the study was to establish theoretical knowledge of nursing students about the procedures of nurses in placing and removing a central venous catheter (CVC), dressing the catheter entry point, the reasons for measuring central venous pressure (CVP), possible complications and risk factors for developing infections related to CVC. The questionnaire developed specifically for this cross-sectionl study was handed out to 87 full-time students and 57 part-time students. The results show that all the surveyed nursing students know why chest radiography is carried out when inserting a catheter, have relatively good knowledge of CVC insertion points, procedures carried out in case of a suspected catheter sepsis and complications and risk factors for the development of infections related to CVC. However, the study show that the majority of students have insufficient knowledge of the procedures accompanying insertion of a catheter, signs that indicate correct functioning of CVC, frequency of flushing a catheter when it is not in use and the reasons for introducing an implanted CVC. Based on the results of the study it can be concluded that the second-year nursing students have insufficient knowledge of CVC. In order to correctly and safely handle a CVC, good theoretical knowledge and relevant practical experience are needed. The authors therefore believe that, in future, the classes should be organized in smaller groups with step-by-step demonstrations of individual procedures in handling a CVC, and the students encouraged to learn as actively as possible.

  17. Catheter-associated bloodstream infections in pediatric hematology-oncology patients: factors associated with catheter removal and recurrence.

    PubMed

    Adler, Amos; Yaniv, Isaac; Solter, Ester; Freud, Enrique; Samra, Zmira; Stein, Jerry; Fisher, Salvador; Levy, Itzhak

    2006-01-01

    The aims of this study were to analyze the factors associated with antibiotic failure leading to tunneled central venous catheter (CVC) removal during catheter-associated bloodstream infections (CABSIs) and with recurrence and reinfection in children with cancer. All cases of CABSI in patients attending the Department of Pediatric Hematology-Oncology between November 2000 and November 2003 were reviewed. A total of 207 episodes of CABSI, including multiple episodes involving the same catheter, were identified in 146 of 410 tunneled CVCs (167 Hickman, 243 implantable ports). The most common organism isolated was coagulase-negative Staphylococcus (CONS). The CVC was removed in 96 (46%) episodes. Hypotension, persistent bacteremia, previous stem cell transplantation, multiple CABSIs in the same CVC, exit-site infection, inappropriate empiric antibiotic therapy, and Candida infection were all significantly associated with increased risk of catheter removal (P < 0.05, odds ratios 7.81, 1.14, 2.22, 1.93, 3.04, 2.04 and 24.53, respectively). There were 12 episodes of recurrent infection, all except 1 caused by CONS (odds ratio 20.5, P = 0.006). Inappropriate empiric therapy, especially in implantable ports, was the only mutable risk factor for antibiotic failure. Because CONS was the predominant isolate in these devices, adding glycopeptides to the empiric therapy for suspected implantable-port CABSI might decrease the removal rate. This issue should be explored in future controlled trials.

  18. Post-procedural evaluation of catheter contact force characteristics

    NASA Astrophysics Data System (ADS)

    Koch, Martin; Brost, Alexander; Kiraly, Atilla; Strobel, Norbert; Hornegger, Joachim

    2012-03-01

    Minimally invasive catheter ablation of electric foci, performed in electrophysiology labs, is an attractive treatment option for atrial fibrillation (AF) - in particular if drug therapy is no longer effective or tolerated. There are different strategies to eliminate the electric foci inducing the arrhythmia. Independent of the particular strategy, it is essential to place transmural lesions. The impact of catheter contact force on the generated lesion quality has been investigated recently, and first results are promising. There are different approaches to measure catheter-tissue contact. Besides traditional haptic feedback, there are new technologies either relying on catheter tip-to-tissue contact force or on local impedance measurements at the tip of the catheter. In this paper, we present a novel tool for post-procedural ablation point evaluation and visualization of contact force characteristics. Our method is based on localizing ablation points set during AF ablation procedures. The 3-D point positions are stored together with lesion specific catheter contact force (CF) values recorded during the ablation. The force records are mapped to the spatial 3-D positions, where the energy has been applied. The tracked positions of the ablation points can be further used to generate a 3-D mesh model of the left atrium (LA). Since our approach facilitates visualization of different force characteristics for post-procedural evaluation and verification, it has the potential to improve outcome by highlighting areas where lesion quality may be less than desired.

  19. Innovating urinary catheter design: An introduction to the engineering challenge.

    PubMed

    Murphy, Cathy

    2018-05-01

    Every day, people around the world rely on intermittent and indwelling urinary catheters to manage bladder dysfunction, but the potential or actual harm caused by these devices is well-recognised. Current catheter designs can cause urinary tract infection and septicaemia, bladder and urethral trauma and indwelling devices frequently become blocked. Furthermore, the devices can severely disrupt users' lives, limiting their daily activities and can be costly to manage for healthcare providers. Despite this, little significant design innovation has taken place in the last 80 years. In this article current catheter designs and their limitations are reviewed, common catheter-associated problems are outlined and areas of design ripe for improvement proposed. The potential to relieve the individual and economic burden of catheter use is high.

  20. Emergency catheter ablation in critical patients

    PubMed Central

    Tebbenjohanns, Jürgen; Rühmkorf, Klaus

    2010-01-01

    Emergency catheter ablation is justified in critical patients with drug-refractory life-threatening arrhythmias. The procedure can be used for ablation of an accessory pathway in preexcitation syndrome with high risk of ventricular fibrillation and in patients with shock due to ischemic cardiomyopathy and incessant ventricular tachycardia. Emergency catheter ablation can also be justified in patients with an electrical storm of the implanted cardioverter-defibrillator or in patients with idiopathic ventricular fibrillation. PMID:20606793

  1. [Epidemiology of catheter-related infections in intensive care unit].

    PubMed

    Merrer, J

    2005-03-01

    Catheter-related infections remain an important cause of nosocomial infection in the ICU. They include colonization of the device, exit-site infection and catheter-related bloodstream infection with or without bacteraemia. Data from clinical studies and surveillance networks should be compared cautiously due to important methodological differences and wide variations of device-utilization ratio between units or countries. In France, two regional networks (C-CLIN Paris-Nord and C-CLIN Sud-Est) produced comparable and reproducible results. Colonization represents five-six cases per 1000 catheter-days and bacteraemia represents one case per 1000 catheter-days. Incidence rates from North American studies are usually four to five times higher. Numerous risk factors have been identified. Some of them could be used to stratify patients according to risk of catheter-related infection and to allow more valid comparison between ICU's performances. Participation of French ICUs to the recent national surveillance networks (REA RAISIN and REACAT RAISIN) should be encouraged.

  2. Peritoneal dialysis catheter implantation: avoiding problems and optimizing outcomes.

    PubMed

    Crabtree, John H

    2015-01-01

    The success of peritoneal dialysis (PD) as renal replacement therapy is dependent upon the patient having a functional long-term peritoneal access. There are a number of identified best practices that must be adhered to during PD catheter placement to achieve a durable and infection-resistant access. The clinical setting, available resources, and the employed catheter insertion method may not always permit complete adherence to these practices; however, an attempt should be made to comply with them as closely as possible. Although omission of any one of the practices can lead to catheter loss, departures from some are committed more frequently, manifesting as commonly occurring clinical problems, such as drain pain, catheter tip migration, omental entrapment, pericatheter leaks and hernias, and poor exit-site location. Understanding the technical pitfalls in PD catheter placement that lead to these problems, enable the provider to modify practice habits to avoid them and optimize outcomes. © 2014 Wiley Periodicals, Inc.

  3. Central venous catheter integrity during mechanical power injection of iodinated contrast medium.

    PubMed

    Macha, Douglas B; Nelson, Rendon C; Howle, Laurens E; Hollingsworth, John W; Schindera, Sebastian T

    2009-12-01

    To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

  4. Catheter tip force transducer for cardiovascular research

    NASA Technical Reports Server (NTRS)

    Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H. (Inventor)

    1976-01-01

    A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter.

  5. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, Jung Suk, E-mail: oj-cumc@daum.net; Lee, Hae Giu, E-mail: hgleehfh@catholic.ac.kr; Chun, Ho Jong

    2013-10-15

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38)more » after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.« less

  6. Urinary catheters: history, current status, adverse events and research agenda

    PubMed Central

    Feneley, Roger C. L.; Hopley, Ian B.; Wells, Peter N. T.

    2015-01-01

    Abstract For more than 3500 years, urinary catheters have been used to drain the bladder when it fails to empty. For people with impaired bladder function and for whom the method is feasible, clean intermittent self-catheterization is the optimal procedure. For those who require an indwelling catheter, whether short- or long-term, the self-retaining Foley catheter is invariably used, as it has been since its introduction nearly 80 years ago, despite the fact that this catheter can cause bacterial colonization, recurrent and chronic infections, bladder stones and septicaemia, damage to the kidneys, the bladder and the urethra, and contribute to the development of antibiotic resistance. In terms of medical, social and economic resources, the burden of urinary retention and incontinence, aggravated by the use of the Foley catheter, is huge. In the UK, the harm resulting from the use of the Foley catheter costs the National Health Service between £1.0–2.5 billion and accounts for ∼2100 deaths per year. Therefore, there is an urgent need for the development of an alternative indwelling catheter system. The research agenda is for the new catheter to be easy and safe to insert, either urethrally or suprapubically, to be retained reliably in the bladder and to be withdrawn easily and safely when necessary, to mimic natural physiology by filling at low pressure and emptying completely without damage to the bladder, and to have control mechanisms appropriate for all users. PMID:26383168

  7. Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.

    PubMed

    Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E

    2009-05-01

    Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.

  8. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dise, J; McDonald, D; Ashenafi, M

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels withmore » similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial

  9. Catheter-associated bloodstream infections in pediatric hematology-oncology patients.

    PubMed

    Celebi, Solmaz; Sezgin, Melike Evim; Cakır, Deniz; Baytan, Birol; Demirkaya, Metin; Sevinir, Betul; Bozdemir, Sefika Elmas; Gunes, Adalet Meral; Hacimustafaoglu, Mustafa

    2013-04-01

    Catheter-associated bloodstream infections (CABSIs) are common complications encountered with cancer treatment. The aims of this study were to analyze the factors associated with recurrent infection and catheter removal in pediatric hematology-oncology patients. All cases of CABSIs in patients attending the Department of Pediatric Hematology-Oncology between January 2008 and December 2010 were reviewed. A total of 44 episodes of CABSIs, including multiple episodes involving the same catheter, were identified in 31 children with cancer. The overall CABSIs rate was 7.4 infections per 1000 central venous catheter (CVC) days. The most frequent organism isolated was coagulase-negative Staphylococcus (CONS). The CVC was removed in nine (20.4%) episodes. We found that hypotension, persistent bacteremia, Candida infection, exit-side infection, neutropenia, and prolonged duration of neutropenia were the factors for catheter removal. There were 23 (52.2%) episodes of recurrence or reinfection. Mortality rate was found to be 9.6% in children with CABSIs. In this study, we found that CABSIs rate was 7.4 infections per 1000 catheter-days. CABSIs rates in our hematology-oncology patients are comparable to prior reports. Because CONS is the most common isolated microorganism in CABSIs, vancomycin can be considered part of the initial empirical regimen.

  10. Do catheter washouts extend patency time in long-term indwelling urethral catheters? A randomized controlled trial of acidic washout solution, normal saline washout, or standard care.

    PubMed

    Moore, Katherine N; Hunter, Kathleen F; McGinnis, Rosemary; Bacsu, Chasta; Fader, Mandy; Gray, Mikel; Getliffe, Kathy; Chobanuk, Janice; Puttagunta, Lakshmi; Voaklander, Donald C

    2009-01-01

    Blockage of long-term indwelling catheters with mineral deposit is an ongoing management issue, but evidence on optimal management is lacking. Our purpose was to examine whether catheter washouts prevent or reduce catheter blockage. A multisite randomized controlled trial. Adults with long-term indwelling catheters that required changing every 3 weeks or less, living in the community, and requiring supportive or continuing care were recruited. Participants were randomly assigned to 1 of 3 groups: control (usual care, no washout), saline washout, or commercially available acidic washout solution (Contisol Maelor Pharmaceuticals Ltd, Wrexham, UK). At baseline visit, the catheter was changed and participants were followed weekly for 8 weeks, with checks for catheter patency and urine pH. Participants randomized to saline or commercial solution had a weekly washout with the appropriate solution. Endpoints were 8 weeks (completion data), 3 or more catheter changes in the 8-week period, or symptomatic urinary tract infection (UTI) requiring antibiotics. The study hypothesis was that catheter life would be extended by 25% in the commercial solution group. It was not possible to blind participants or research nurses to washout versus no intervention, but participants in the saline and washout solution groups were blinded to solution type. One hundred twelve potential participants were screened; 73 were enrolled, randomized, and included in the final analysis. Of these, 53 completed the full 8 weeks of data collection; 16 terminated early because of 3 catheter changes or self-reported 'UTI'. Other reasons for termination were hematuria, latex sensitivity, deceased/severe illness, or personal choice. Analysis of variance was used to analyze mean differences on demographic variables and mean number of weeks in study. Kaplan-Meier survival curve analysis showed no statistical difference between the groups in time to first catheter change. At this time, the evidence is

  11. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    PubMed

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  12. Urethral versus suprapubic catheter: choosing the best bladder management for male spinal cord injury patients with indwelling catheters.

    PubMed

    Katsumi, H K; Kalisvaart, J F; Ronningen, L D; Hovey, R M

    2010-04-01

    Bladder management for male patients with spinal cord injury (SCI) challenges the urologist to work around physical and social restrictions set forth by each patient. The objective of this study was to compare the complications associated with urethral catheter (UC) versus suprapubic tube (SPT) in patients with SCI. A retrospective review of records at Long Beach Veterans Hospital was carried out to identify SCI patients managed with SPT or UC. Chart review identified morbidities including urinary tract infection (UTI), bladder stones, renal calculi, urethral complications, scrotal abscesses, epididymitis, gross hematuria and cancer. Serum creatinine measurements were evaluated to determine whether renal function was maintained. In all, 179 patients were identified. There was no significant difference between the two catheter groups in any areas in which they could be compared. There were catheter-specific complications specific to each group that could not be compared. These included erosion in the UC group and urethral leak, leakage from the SPT and SPT revision in the SPT group. Average serum creatinine for the UC and SPT groups was 0.74 and 0.67 mg per 100 ml, respectively. SCI patients with a chronic catheter have similar complication rates of UTIs, recurrent bladder/renal calculi and cancer. Urethral and scrotal complications may be higher with UC; however, morbidity from SPT-specific procedures may offset benefits from SPT. Serum creatinine was maintained in both groups. Overall, bladder management for patients with chronic indwelling catheters should be selected on the basis of long-term comfort for the patient and a physician mind-set that allows flexibility in managing these challenges.

  13. [Central venous catheter-related infections in critically ill patients].

    PubMed

    Diener, J R; Coutinho, M S; Zoccoli, C M

    1996-01-01

    To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.

  14. Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulcsar, Zsolt, E-mail: kulcsarzsolt22@gmail.com; Yilmaz, Hasan; Bonvin, Christophe

    2010-12-15

    In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted ofmore » an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.« less

  15. Design, development and evaluation of a compact telerobotic catheter navigation system.

    PubMed

    Tavallaei, Mohammad Ali; Gelman, Daniel; Lavdas, Michael Konstantine; Skanes, Allan C; Jones, Douglas L; Bax, Jeffrey S; Drangova, Maria

    2016-09-01

    Remote catheter navigation systems protect interventionalists from scattered ionizing radiation. However, these systems typically require specialized catheters and extensive operator training. A new compact and sterilizable telerobotic system is described, which allows remote navigation of conventional tip-steerable catheters, with three degrees of freedom, using an interface that takes advantage of the interventionalist's existing dexterity skills. The performance of the system is evaluated ex vivo and in vivo for remote catheter navigation and ablation delivery. The system has absolute errors of 0.1 ± 0.1 mm and 7 ± 6° over 100 mm of axial motion and 360° of catheter rotation, respectively. In vivo experiments proved the safety of the proposed telerobotic system and demonstrated the feasibility of remote navigation and delivery of ablation. The proposed telerobotic system allows the interventionalist to use conventional steerable catheters; while maintaining a safe distance from the radiation source, he/she can remotely navigate the catheter and deliver ablation lesions. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Minimally invasive fluoroscopic percutaneous peritoneal dialysis catheter salvage.

    PubMed

    Narayan, Rajeev; Fried, Terrance; Chica, Gerardo; Schaefer, Mathew; Mullins, Daniel

    2014-06-01

    Peritoneal dialysis catheter (PDC) dysfunction can often be treated fluoroscopically by manipulation with wire, balloon or stiff stylet, saving surgical intervention for refractory cases. We describe an enhanced percutaneous approach to PDC salvage that can lead to a more definitive intervention and salvage for cases refractory to fluoroscopic manipulation. In five cases of PD catheter malfunction, the deep cuff was dissected free after a 0.035 hydrophilic wire was passed into the peritoneum through the PDC. Only the intraperitoneal portion of the PDC was explanted. The PDC was cleared of obstruction and omentum. The intraperitoneal portion of the PDC was reimplanted over wire via a peel-away sheath and the deep cuff sutured. Omental entrapment was present in three of five patients and fibrin occlusion in four of the five cases. All catheters were repaired successfully by the described technique. Post procedure, 3-5 days of lower volume, recumbent PD exchanges were performed prior to full-dose PD. No perioperative complications or leaks were noted. All PDCs were patent at 6 months. One patient required laparoscopy for recurrent omental wrapping 3 months post intervention. PDC salvage in this manner is a cost-effective alternative to laparoscopic repair of PDCs failing catheter manipulation. The infection barrier afforded by the original superficial cuff and subcutaneous tunnel is maintained. PD can be resumed immediately. Only refractory cases need laparoscopy. This procedure allows for a more definitive correction of catheter migration and obstruction, avoids placement of a new PDC or temporary hemodialysis, is cost-effective and expands percutaneous options for dysfunctional PD catheters.

  17. Utility and safety of Hickman catheters for venous access after bone marrow transplantation.

    PubMed

    Kumagai, T; Sakamaki, H; Tanikawa, S; Akiyama, H; Maeda, Y; Sasaki, T; Tsuzuki, S; Takamoto, S; Takahashi, K; Onozawa, Y

    1998-03-01

    Hickman catheters are useful for vascular access after bone marrow transportation because they can handle large volume and allow for easy transfusions and blood drawing through wide double lumens making it easier to case for patients under sterile conditions in a clean room. However, the safety of Hickman catheters as compared to Silastic catheters in marrow transplants has never been discussed. We therefore retrospectively reviewed the complications of two catheters in 71 allogeneic bone marrow transplant recipients between September 1986 and August 1994. The complication and infection rates of Hickman catheters were 0.21 and 0.09 per 100 device-life days, and rate of temperature >38 degrees C during leukocytopenia (<1,000 white blood cells) was 0.18. These rates were not different from those of Silastic catheters suggesting that Hickman catheters are safe and acceptable in marrow transplantation. The benefits and drawbacks of Hickman catheters relevant to catheter choice were also discussed.

  18. Vascular Access Tracking System: a Web-Based Clinical Tracking Tool for Identifying Catheter Related Blood Stream Infections in Interventional Radiology Placed Central Venous Catheters.

    PubMed

    Morrison, James; Kaufman, John

    2016-12-01

    Vascular access is invaluable in the treatment of hospitalized patients. Central venous catheters provide a durable and long-term solution while saving patients from repeated needle sticks for peripheral IVs and blood draws. The initial catheter placement procedure and long-term catheter usage place patients at risk for infection. The goal of this project was to develop a system to track and evaluate central line-associated blood stream infections related to interventional radiology placement of central venous catheters. A customized web-based clinical database was developed via open-source tools to provide a dashboard for data mining and analysis of the catheter placement and infection information. Preliminary results were gathered over a 4-month period confirming the utility of the system. The tools and methodology employed to develop the vascular access tracking system could be easily tailored to other clinical scenarios to assist in quality control and improvement programs.

  19. Diastasis of rectus abdominis muscles in low back pain patients.

    PubMed

    Doubkova, Lucie; Andel, Ross; Palascakova-Springrova, Ingrid; Kolar, Pavel; Kriz, Jiri; Kobesova, Alena

    2018-02-06

    Abdominal muscles are important spinal stabilizers and its poor coordination, as seen in diastasis of rectus abdominis (DRA), may contribute to chronic low back pain (LBP). However, this has not yet been studied directly. To conduct a pilot study to examine the association between DRA and LBP. Using a digital caliper, standard clinical DRA measurement was performed in 55 participants with and 54 without chronic LBP. Participants were on average 55 years old, 69 (63%) were women. Among the 16 participants with DRA, 11 (69%) had chronic LBP; among the 93 participants without DRA, 44 (47%) had LBP. Among men, 7 of 9 (77%) with DRA had LBP and 14 of 31 (45%) without DRA had LBP. Among women, 4 of 7 (57%) with DRA had LBP and 30 of 62 (48%) without DRA had LBP. BMI was the strongest correlate of DRA and may explain the relation between DRA and chronic LBP. DRA and LBP may be interrelated, especially among men. This may be a function of greater BMI in individuals with chronic LBP. Understanding the association between DRA, LBP, and BMI may have important implications for treatment of LBP and for intervention.

  20. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    PubMed

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  1. Infection and natural history of emergency department-placed central venous catheters.

    PubMed

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  2. Reliability of real-time ultrasound for the assessment of transversus abdominis function.

    PubMed

    Kidd, Adrian W; Magee, Scott; Richardson, Carolyn A

    2002-07-01

    Transversus abdominis (TrA) has now been established as a key muscle for the stabilization of the lumbar spine and sacroiliac joints. Significantly, dysfunction of this muscle has also been implicated in low back pain. Real-time ultrasound (US) is a non-invasive procedure that has the potential to evaluate objectively the function of TrA. To investigate M-mode US as a reliable method of assessing TrA function. M-mode US was used to measure the width of TrA as subjects drew in their lower abdominal wall at a controlled speed to a target depth. Eleven subjects were imaged. the measures of TrA width were reliable and ranged between 3.14mm relaxed and 6.35mm contracted. The standard error of measurement ranged between 0.18mm and 0.57mm. M-mode US provides a reliable non-invasive measure of a controlled contraction of TrA.

  3. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  4. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip pressure transducer. 870.2870 Section 870.2870 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2870 Catheter tip...

  5. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870.1350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1350 Catheter balloon...

  6. [Persistent neonatal hypoglycaemia caused by arterial positioning of the umbilical venous catheter].

    PubMed

    Peters, P A G; Brus, F; Noordam, C; Smorenburg, M K; van Setten, P A

    2007-10-06

    Two neonates, a girl born at 40 2/7 weeks weighing 4165 g and a boy born at 37 6/7 weeks weighing 4040 g, received umbilical venous catheters to help manage hypoglycaemia. The catheter was ineffective or only effective when high doses of glucose were used, due to what later appeared to be arterial positioning of the catheter. Both patients recovered without consequences. Persistent hypoglycaemia is a common problem in newborns and can cause severe neurological sequelae. A relatively uncommon cause is malpositioning of the umbilical catheter. Positioning in an artery leads to direct infusion of glucose into the pancreas, which causes hyperinsulinaemia and can lead to potentially dangerous nonketotic hypoglycaemia. Arterial positioning of the umbilical catheter should be ruled out at an early stage. Correct catheter positioning can be determined using careful inspection of the umbilical veins, radiological examination of the catheter position, blood gas analysis or vascular pulsation.

  7. Patient-specific catheter shaping for the minimally invasive closure of the left atrial appendage.

    PubMed

    Graf, Eva C; Ott, Ilka; Praceus, Julian; Bourier, Felix; Lueth, Tim C

    2018-06-01

    The minimally invasive closure of the left atrial appendage is a promising alternative to anticoagulation for stroke prevention in patients suffering from atrial fibrillation. One of the challenges of this procedure is the correct positioning and the coaxial alignment of the tip of the catheter sheath to the implant landing zone. In this paper, a novel preoperative planning system is proposed that allows patient-individual shaping of catheters to facilitate the correct positioning of the catheter sheath by offering a patient-specific catheter shape. Based on preoperative three-dimensional image data, anatomical points and the planned implant position are marked interactively and a patient-specific catheter shape is calculated if the standard catheter is not considered as suitable. An approach to calculate a catheter shape with four bends by maximization of the bending radii is presented. Shaping of the catheter is supported by a bending form that is automatically generated in the planning program and can be directly manufactured by using additive manufacturing methods. The feasibility of the planning and shaping of the catheter could be successfully shown using six data sets. The patient-specific catheters were tested in comparison with standard catheters by physicians on heart models. In four of the six tested models, the participating physicians rated the patient-individual catheters better than the standard catheter. The novel approach for preoperatively planned and shaped patient-specific catheters designed for the minimally invasive closure of the left atrial appendage could be successfully implemented and a feasibility test showed promising results in anatomies that are difficult to access with the standard catheter.

  8. Staphylococcus-Infected Tunneled Dialysis Catheters: Is Over-the-Wire Exchange an Appropriate Management Option?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langer, Jessica M.; Cohen, Raphael M.; Berns, Jeffrey S.

    Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n =more » 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.« less

  9. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    PubMed

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  10. Complications Related to Insertion and Use of Central Venous Catheters (CVC).

    PubMed

    Hodzic, Samir; Golic, Darko; Smajic, Jasmina; Sijercic, Selma; Umihanic, Sekib; Umihanic, Sefika

    2014-10-01

    Central Venous Catheters (CVC) are essential in everyday medical practice, especially in treating patients in intensive care units (ICU). The application of these catheters is accompanied with the risk of complications, such as the complications caused during the CVC insertion, infections at the location of the insertion, and complications during the use of the catheter, sepsis and other metastatic infections. This study is a retrospective-prospective and it was implemented in the period 1(st) January 2011- 31(st) December 2012. It included 108 examinees with CVC placed for more than 7 days. The most common complications occurring in more than 2 attempts of CVC applications are: hearth arrhythmias in both groups in 12 cases, 7 in multi-lumen (12.72%) and 5 in mono-lumen ones (9.43%). Artery puncture occurs in both groups in 7 cases, 5 in multi-lumen (9.09%) and 2 in mono-lumen ones (3.77%). Hematoma occurred in both groups in 4 cases, 3 in multi-lumen CVCs (5.45%) and 1 in mono-lumen ones (1.88%). The most common complication in multi-lumen catheters was heart arrhythmia, in 20 cases (36.37%). The most common complications in mono-lumen CVCs was hearth arrhythmias, in 20 cases as extrasystoles and they were registered in 16 catheter insertions (30.18%). Out of total number of catheters of both groups, out of 108 catheters the complications during insertion occurred in 49 catheters (45.40%). The most common complications in both groups were heart arrhythmias, artery punctures and hematomas at the place of catheter insertion.

  11. Permcath Catheter Embolization: a Case Report

    PubMed Central

    Yousefshahi, Hadi; Bina, Payvand; Yousefshahi, Fardin

    2015-01-01

    Introduction: Nowadays, many types of intravascular devices and catheters are used in order to diagnose and treat diseases. Complications related to these instruments are the costs that doctors and patients have to pay to benefit from their advantages. Catheter embolization is one of these side effects. Patients with devices in their cardiopulmonary system are at risk for severe complications such as arrhythmias, pulmonary embolism, myocardial injuries, hemoptysis, thrombosis and perforation. Case Presentation: A 50-years-old woman, with a history of breast cancer, had a PermCath emplacement in right subclavian vein for a course of chemotherapy. The treatment for cancer seemed to be successful and the PermCath had remained in its position without complication, for a couple of years however, the catheter was founded broken and embolized to the right ventricle and the main left pulmonary artery, diagnosed by a chest X-ray study incidentally. Conclusions: It is better to remove the unused devices safely to prevent and decrease their possible complications. PMID:25964881

  12. Permcath catheter embolization: a case report.

    PubMed

    Yousefshahi, Hadi; Bina, Payvand; Yousefshahi, Fardin

    2015-04-01

    Nowadays, many types of intravascular devices and catheters are used in order to diagnose and treat diseases. Complications related to these instruments are the costs that doctors and patients have to pay to benefit from their advantages. Catheter embolization is one of these side effects. Patients with devices in their cardiopulmonary system are at risk for severe complications such as arrhythmias, pulmonary embolism, myocardial injuries, hemoptysis, thrombosis and perforation. A 50-years-old woman, with a history of breast cancer, had a PermCath emplacement in right subclavian vein for a course of chemotherapy. The treatment for cancer seemed to be successful and the PermCath had remained in its position without complication, for a couple of years however, the catheter was founded broken and embolized to the right ventricle and the main left pulmonary artery, diagnosed by a chest X-ray study incidentally. It is better to remove the unused devices safely to prevent and decrease their possible complications.

  13. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    PubMed

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  14. [Yeast colonization of urinary catheters and the significance of biofilm formation].

    PubMed

    Růžička, Filip; Holá, Veronika; Mahelová, Martina; Procházková, Alena

    2012-08-01

    Urinary catheters are colonized by a wide range of microorganisms, including numerous yeasts. The catheters are usually colonized by more microbial species forming a community - multispecies biofilm. Catheter colonization usually does not affect the patient's clinical status in any significant way. On the other hand, the biofilm can become a source of endogenous infection and its presence can affect functionality of the catheter and formation of urinary stones. Material a A total of 721 urinary catheters were studied. Microorganisms were released from catheters by sonication and subsequently cultured. Their identification was performed with the use of common phenotypic tests, as well as using MALDI TOF. Yeasts whose identification was ambiguous were recognized by sequencing. Biofilm formation was assessed by growth in a microtiter plate. Yeast colonization was proved in 244 urinary catheters. However, a total of 274 yeast strains were isolated. Most of them occurred together with other yeast species and/or bacteria on the catheters, producing multispecies biofilm there. The most frequent species was Candida albicans (a total of 144 isolated strains), followed by Candida glabrata (41), Candida tropicalis (41) and Candida parapsilosis sensu stricto (14). Other isolated species were as follows: Candida kefyr (10), Candida krusei (9), Candida fabianii (6), Candida lusitaniae (5), Candida dubliniensis (3) and Saccharomyces cerevisiae (one case). Most of the yeasts rather readily formed a firmly adhering biofilm layer on artificial surfaces.

  15. Cost-Effectiveness of a Central Venous Catheter Care Bundle

    PubMed Central

    Halton, Kate A.; Cook, David; Paterson, David L.; Safdar, Nasia; Graves, Nicholas

    2010-01-01

    Background A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI). Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. Methods and Findings A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters), or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. Conclusions A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision makers must be prepared

  16. Cost-effectiveness of a central venous catheter care bundle.

    PubMed

    Halton, Kate A; Cook, David; Paterson, David L; Safdar, Nasia; Graves, Nicholas

    2010-09-17

    A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI). Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters), or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision makers must be prepared to invest resources in infection control to

  17. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  18. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  19. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  20. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  1. Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters.

    PubMed

    Brandt, C P; Ricanati, E S

    1996-01-01

    The proper function of peritoneal dialysis (PD) catheters can be compromised by catheter malposition, fibrin clot, or omental wrapping. The purpose of this study was to determine the efficacy of laparoscopy in the treatment of malfunctioning PD catheters. All patients undergoing laparoscopy for catheter dysfunction at MetroHealth Medical Center in Cleveland, Ohio, from 1991 to 1995, were reviewed. Twenty-six laparoscopies were performed in 22 patients, for malfunction occurring an average of 3.9 months following insertion (range 0.5-18 months). Omental and/or small below wrapping as present in all but three cases. Lysis of adhesions was required in 19 of 26 cases, with repositioning only in seven. Eight patients had failed attempts at stiff wire manipulation prior to laparoscopy. Perioperative complications occurred in seven cases, consisting of temporary dialysate leakage (2), enterotomy (1), and early reocclusion (4). Repeat laparoscopy was successful in three of these four reocclusions. The overall success rate (catheter function > 30 days after laparoscopy) was 21/22 (96%). Laparoscopy is highly accurate and effective in the management of peritoneal dialysis catheter dysfunction and results in prolongation of catheter life.

  2. Endovascular recanalization of a port catheter-associated superior vena cava syndrome.

    PubMed

    Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter

    2015-01-01

    Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.

  3. Femoral venous access is safe in burned children: an analysis of 224 catheters.

    PubMed

    Goldstein, A M; Weber, J M; Sheridan, R L

    1997-03-01

    To document the incidence of septic and mechanical complications associated with femoral venous catheters in a subgroup of patients thought to be at particularly high risk of both: young children with large burns. An analysis of data collected prospectively on all femoral venous catheters placed during a 4-year period at a regional pediatric burn facility. There were 224 femoral catheters placed in 86 children with an average age of 5.3 +/- 5.1 years and an average burn size of 38% +/- 23%. Catheters were left in place for a mean duration of 5.7 days. Catheter-related sepsis occurred with 4.9% of the catheters, and mechanical complications occurred in 3.5% of the patients. There was no statistically significant association between the risk of catheter sepsis and the placement of catheters through burned versus unburned skin. Similarly, the risk of sepsis was equivalent between lines placed over a guide wire and those placed of a new site. Femoral venous catheters are safe in burned children and are associated with a low incidence of infectious and mechanical complications.

  4. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions.

    PubMed

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-05-23

    BACKGROUND The GuideLiner catheter extension device is a monorail-type "Child" support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). CASE REPORT We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guidewires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. CONCLUSIONS The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion.

  5. Local wound infiltration plus transversus abdominis plane (TAP) block versus local wound infiltration in laparoscopic colorectal surgery and ERAS program.

    PubMed

    Pedrazzani, Corrado; Menestrina, Nicola; Moro, Margherita; Brazzo, Gianluca; Mantovani, Guido; Polati, Enrico; Guglielmi, Alfredo

    2016-11-01

    Few data are available on TAP block in laparoscopic colorectal surgery and ERAS program. The aim of this prospective study was to evaluate local wound infiltration plus TAP block compared to local wound infiltration in the management of postoperative pain, nausea and vomiting, ileus and use of opioids in the context of laparoscopic colorectal surgery and ERAS program. From March 2014 to March 2015, 48 patients were treated by laparoscopic resection and ERAS program for colorectal cancer and diverticular disease at the Division of General and Hepatobiliary Surgery, University of Verona Hospital Trust. Among these, 24 patients received local wound infiltration plus TAP block (TAP block group) and 24 patients received local wound infiltration (control group). No differences were observed in baseline patient characteristics, clinical variables and surgical procedures between the two groups. Local wound infiltration plus TAP block allowed to achieve pain control despite a reduced use of opioid analgesics (P = 0.009). The adoption of TAP block resulted beneficial on the prevention of postoperative nausea (P = 0.002) and improvement of essential outcomes of ERAS program as recovery of bowel function (P = 0.005), urinary catheter removal (P = 0.003) and capability to tolerate oral diet (P = 0.027). TAP block plus local wound infiltration in the setting of laparoscopic colorectal surgery and ERAS program guarantees a reduced use of opioid analgesics and good pain control allowing the improvement of essential items of enhanced recovery pathways.

  6. A prospective randomized trial of the LoFric hydrophilic coated catheter versus conventional plastic catheter for clean intermittent catheterization.

    PubMed

    Vapnek, Jonathan M; Maynard, Frederick M; Kim, Jiensup

    2003-03-01

    We compared the incidence of hematuria, pyuria and clinical urinary tract infection in patients who performed intermittent self-catheterization using a hydrophilic coated LoFric (Astra Tech AB, Mölndal, Sweden) or standard plastic catheter. A total of 62 male patients who performed intermittent self-catheterization to manage neurogenic bladder were randomized into 2 treatment groups at 3 American study sites. Outcome measures included urinary tract infection, microhematuria, pyuria and satisfaction rates. Of the 62 enrolled patients 49 completed the 12-month study. The withdrawal rate was not different in the 2 groups. At the end of the study there was statistically significantly less hematuria in the hydrophilic coated catheter group compared with controls. In addition, there was a significant decrease in the urinary tract infection rate from baseline in the hydrophilic coated catheter group but not in controls. Use of the hydrophilic coated catheter by patients on intermittent self-catheterization is associated with less hematuria and a significant decrease in the incidence of urinary tract infections. Therefore, it may be preferable for some patients, especially those with a history of difficult catheterization, urethral trauma or a high rate of urinary tract infection.

  7. Catheter use and infection reduction in plastic surgery

    PubMed Central

    Barnes, Zach J; Mahabir, Raman C

    2013-01-01

    BACKGROUND: Catheter-associated urinary tract infections (CAUTI) are the most common hospital-associated infection and can result in increased health care costs, morbidity and even mortality. In 2009, The Scott & White Memorial Hospital/Texas A&M Health Science Center (Texas, USA) system’s CAUTI rate placed it in the upper quartile (ie, highest rate) for the country, necessitating a system-wide change. OBJECTIVE: To design and implement a guideline to reduce the incidence of CAUTI. METHODS: A multidisciplinary team was formed and completed both a root cause analysis and a review of the available literature. Consolidating the best evidence, the team formulated a best practice guideline detailing the proper indications for insertion of, improper use of and techniques to minimize infection with catheters. Included as part of this protocol was nursing and patient education, changes in identifying patients with a catheter and automatic termination orders. Three-, six- and 12-month reviews identifying additional opportunities for improvement at the end of 2010 were completed. RESULTS: In 2009, the hospital’s CAUTI rate was 1.46 per 1000 catheter days. In 2011 – the first complete year of the finalized guideline – the hospital’s CAUTI rate was 0.52 per 1000 catheter days, ranking the institution in the bottom quartile (ie, lowest rate) for the country. The surgery and plastic surgery subgroup analyses also demonstrated statistically significant reduction in both catheter use and CAUTI. CONCLUSION: The incidence of CAUTI was successfully reduced at The Texas A&M Healthcare Center. The guideline, its development and how it applies to plastic surgery patients are discussed. PMID:24431946

  8. Intracranial placement of a new, compliant guide catheter: technical note.

    PubMed

    Park, Min S; Stiefel, Michael F; Fiorella, David; Kelly, Michael; McDougall, Cameron G; Albuquerque, Felipe C

    2008-09-01

    We describe our initial experience with the use of a novel, compliant guide catheter designed for placement within the cranial vasculature in a series of seven patients who were treated for various intracranial pathologies. Seven patients were deemed to have either tortuous supra-aortic, intracranial, and/or extracranial vasculature or to require additional microcatheter support as the result of lesion location. The patients were treated, in part, with the 6-French Neuron delivery catheter (Penumbra, Inc., San Leandro, CA) at the authors' two institutions. The guide catheter was positioned in various distal locations within the intracranial internal carotid artery or external carotid artery. Three patients were treated for unruptured intracranial aneurysms, 2 patients for intracranial atherosclerosis, 1 patient for an arteriovenous malformation, and 1 patient for a pseudoaneurysm. All lesions were successfully treated through a microcatheter advanced in a coaxial fashion through the guide catheter. There were no complications related to the positioning of the catheter. Distal intra- or extracranial placement of a specially designed, compliant guide catheter can be performed safely and may improve access and microcatheter stability in patients with tortuous vessels or difficult-to-reach lesions.

  9. An Effective Technique for Enhancing an Intrauterine Catheter Fetal Electrocardiogram

    NASA Astrophysics Data System (ADS)

    Horner, Steven L.; Holls, William M.

    2003-12-01

    Physician can obtain fetal heart rate, electrophysiological information, and uterine contraction activity for determining fetal status from an intrauterine catheters electrocardiogram with the maternal electrocardiogram canceled. In addition, the intrauterine catheter would allow physicians to acquire fetal status with one non-invasive to the fetus biosensor as compared to invasive to the fetus scalp electrode and intrauterine pressure catheter used currently. A real-time maternal electrocardiogram cancellation technique of the intrauterine catheters electrocardiogram will be discussed along with an analysis for the methods effectiveness with synthesized and clinical data. The positive results from an original detailed subjective and objective analysis of synthesized and clinical data clearly indicate that the maternal electrocardiogram cancellation method was found to be effective. The resulting intrauterine catheters electrocardiogram from effectively canceling the maternal electrocardiogram could be used for determining fetal heart rate, fetal electrocardiogram electrophysiological information, and uterine contraction activity.

  10. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass vascular catheter, cannula... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to...

  11. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass vascular catheter, cannula... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to...

  12. A new disposable MEMS-based manometric catheter for in-vivo medical tests

    NASA Astrophysics Data System (ADS)

    Teng, Ming-Foey; Hariz, Alex J.; Hsu, Hung-Yao

    2006-12-01

    In this paper we report on the development of a new disposable manometric catheter for diagnosis of functional swallowing disorders. The function of this catheter is to measure the intrabolus and peak pressures occurring along the esophageal tract during the swallowing process. Traditionally, in hospitals the water perfusion technique is used to diagnose the disorder. Current manometric catheters developed elsewhere use a solid-state pressure sensor mounted directly on a thin catheter to measure the pressure changes. Both types of catheters are re-usable due to the high running cost, and this in turn increases the risk of contamination among patients, and creates hygiene problems. We have developed a new disposable manometric catheter which consists of a MEMS-based pressure sensor. Recent laboratory characterizations and hospital in-vivo tests show the new developed low cost disposable catheter prototype capable of measuring pressure ranges of 0 to 100mmHg. The in-vivo tests have also shown the new catheter prototype capable of measuring the peak pressure as well as the intrabolus pressure which is a very important parameter for doctors to carry out the required diagnosis.

  13. The left atrial catheter: its uses and complications.

    PubMed

    Leitman, B S; Naidich, D P; McGuinness, G; McCauley, D I

    1992-11-01

    The authors describe the radiographic appearance of the left atrial catheter, a widely used postsurgical intracardiac device. Recognition of the characteristic appearance of this catheter should be of value in detection of potential complications, including line fracture with resultant retention and/or embolization, infection, prosthetic valve dysfunction, and even cardiac tamponade.

  14. Early catheter removal after radical retropubic prostatectomy: long-term followup.

    PubMed

    Koch, Michael O; Nayee, Anish H; Sloan, James; Gardner, Thomas; Wahle, Greg R; Bihrle, Richard; Foster, Richard S

    2003-06-01

    We examine the complication and continence rates with early catheter removal (day 3 or 4) after radical retropubic prostatectomy. A total of 365 patients with localized prostate cancer underwent radical retropubic prostatectomy at Indiana University Hospital with planned urethral catheter removal before discharge home. Low pressure cystograms were performed on postoperative day 3 or 4 to determine if catheter removal was possible. A subset of patients were analyzed using a validated prostate cancer specific questionnaire (University of California, Los Angeles Prostate Cancer Symptom Index) to determine quality of life outcomes. The catheter was removed on postoperative day 3 or 4 in 263 patients (72%). The reasons for leaving the catheter indwelling were significant leak on cystogram or excessive suprapubic drainage (21%), extensive bladder neck reconstruction (1%) and prolonged hospitalization because of an ileus or other complicating factor (6%). Thirteen patients (3.6%) were either unable to void after catheter removal or presented with retention (not associated with hematuria or clots) after hospital discharge, requiring reinsertion of the Foley catheter. A total of 41 patients (11%) had either an early or late complication (excluding incontinence). There were 3 complications (0.8%) that were considered major because they were potentially life threatening or required a return to the operating room. A pelvic abscess developed in 2 patients and a lymphocele in 1, which required percutaneous drainage. After at least 6 months (mean 20.9 months) 140 patients (89.2%) and 14 (8.9%) reported excellent and good continence, respectively. The patient questionnaire demonstrated bother scores to be minimal to no bother for 95% to 98% of patients at 6 and 12 months. This study confirms that it is safe to remove catheters in most patients 3 to 4 days after prostatectomy if a cystogram demonstrates no extravasation. Complication rates and continence rates with this approach

  15. Nitric oxide charged catheters as a potential strategy for prevention of hospital acquired infections.

    PubMed

    Margel, David; Mizrahi, Mark; Regev-Shoshani, Gili; Ko, Mary; Moshe, Maya; Ozalvo, Rachel; Shavit-Grievink, Liat; Baniel, Jack; Kedar, Daniel; Yossepowitch, Ofer; Lifshitz, David; Nadu, Andrei; Greenberg, David; Av-Gay, Yossef

    2017-01-01

    Catheter-Associated Hospital-Acquired Infections (HAI's) are caused by biofilm-forming bacteria. Using a novel approach, we generated anti-infective barrier on catheters by charging them with Nitric Oxide (NO), a naturally-produced gas molecule. NO is slowly released from the catheter upon contact with physiological fluids, and prevents bacterial colonization and biofilm formation onto catheter surfaces. The aim of the study was to assess the anti-infective properties of NO-charged catheters exposed to low concentration (up to 103 CFU/ml) of microbial cells in-vitro. We assessed NO-charged tracheal tubes using Pseudomonas aeruginosa, dialysis and biliary catheters using Escherichia coli, and urinary catheters using E. coli, Candida albicans or Enterococcus faecalis. Safety and tolerability of NO-charged urinary catheters were evaluated in a phase 1 clinical study in 12 patients. Six patients were catheterized with NO-charged catheters (NO-group), followed by 6 patients catheterized with regular control catheters (CT-group). Comparison of safety parameters between the study groups was performed. NO-charged tracheal, dialysis biliary and urinary catheters prevented P. aeruginosa, E. coli and C. albicans attachment and colonization onto their surfaces and eradicated corresponding planktonic microbial cells in the surrounding media after 24-48 hours, while E. faecalis colonization onto urinary catheters was reduced by 1 log compared to controls. All patients catheterized with an NO-charged urinary catheter successfully completed the study without experiencing NO-related AE's or serious AE's (SAE's). These data highlight the potential of NO-based technology as potential platform for preventing catheter-associated HAI's.

  16. Nitric oxide charged catheters as a potential strategy for prevention of hospital acquired infections

    PubMed Central

    Regev-Shoshani, Gili; KO, Mary; Moshe, Maya; Ozalvo, Rachel; Shavit-Grievink, Liat; Baniel, Jack; Kedar, Daniel; Yossepowitch, Ofer; Lifshitz, David; Nadu, Andrei; Greenberg, David; Av-Gay, Yossef

    2017-01-01

    Background Catheter-Associated Hospital-Acquired Infections (HAI's) are caused by biofilm-forming bacteria. Using a novel approach, we generated anti-infective barrier on catheters by charging them with Nitric Oxide (NO), a naturally-produced gas molecule. NO is slowly released from the catheter upon contact with physiological fluids, and prevents bacterial colonization and biofilm formation onto catheter surfaces. Aims and methods The aim of the study was to assess the anti-infective properties of NO-charged catheters exposed to low concentration (up to 103 CFU/ml) of microbial cells in-vitro. We assessed NO-charged tracheal tubes using Pseudomonas aeruginosa, dialysis and biliary catheters using Escherichia coli, and urinary catheters using E. coli, Candida albicans or Enterococcus faecalis. Safety and tolerability of NO-charged urinary catheters were evaluated in a phase 1 clinical study in 12 patients. Six patients were catheterized with NO-charged catheters (NO-group), followed by 6 patients catheterized with regular control catheters (CT-group). Comparison of safety parameters between the study groups was performed. Results NO-charged tracheal, dialysis biliary and urinary catheters prevented P. aeruginosa, E. coli and C. albicans attachment and colonization onto their surfaces and eradicated corresponding planktonic microbial cells in the surrounding media after 24–48 hours, while E. faecalis colonization onto urinary catheters was reduced by 1 log compared to controls. All patients catheterized with an NO-charged urinary catheter successfully completed the study without experiencing NO-related AE's or serious AE's (SAE's). Conclusion These data highlight the potential of NO-based technology as potential platform for preventing catheter-associated HAI's. PMID:28410367

  17. Micrococcus-associated central venous catheter infection in patients with pulmonary arterial hypertension.

    PubMed

    Oudiz, Ronald J; Widlitz, Allison; Beckmann, X Joy; Camanga, Daisy; Alfie, Jose; Brundage, Bruce H; Barst, Robyn J

    2004-07-01

    To determine the incidence of catheter-related infection in patients with pulmonary arterial hypertension (PAH) receiving epoprostenol (EPO), and to note an etiologic role for Micrococcus spp, which is rarely reported as a pathogen in the medical literature. Observational study. Two PAH specialty treatment centers, Harbor-UCLA Medical Center (Torrance, CA), and the College of Physicians and Surgeons, Columbia University (New York, NY). A total of 192 patients with PAH receiving continuous therapy with IV EPO. From 1987 to 2000, 192 patients with PAH received infusions of EPO via central venous catheter. Catheter care included regular dressing changes with dry gauze using a sterile procedure, without the use of flushes. Patients were asked to report on known infections and treatments, and symptoms. All infections were verified by a telephone call to the patient, care provider, and microbiology laboratory whenever possible. There were 335,285 catheter days (mean +/- SD, 1,325 +/- 974 catheter days). There were 88 clinical catheter infections with 51 blood culture-positive infections, necessitating catheter removal in 38 instances. The following pathogens were isolated: Staphylococcus aureus (25); Micrococcus spp (14); mixed flora (3); coagulase-negative Staphylococcus spp (2); Corynebacterium spp (2); Serratia marcessens (1); Enterobacter spp (1); Pseudomonas aeruginosa (1); enterococci (1); and unidentified Gram-positive cocci (1). The catheter infection rate was 0.26 per 1,000 catheter days. The use of long-term therapy with continuous EPO appears to be associated with a low incidence of catheter-related infections. Micrococcus spp were the second most common etiologic agent. Caregivers managing patients with PAH must be aware of the risk of catheter infection, as it may contribute to the morbidity and mortality associated with the use of EPO. When isolated, Micrococcus spp should not be viewed as a contaminant, but rather as a true pathogen that may require

  18. Decreasing dialysis catheter rates by creating a multidisciplinary dialysis access program.

    PubMed

    Rosenberry, Patricia M; Niederhaus, Silke V; Schweitzer, Eugene J; Leeser, David B

    2018-03-01

    Centers for Medicare and Medicaid Services have determined that chronic dialysis units should have <12% of their patients utilizing central venous catheters for hemodialysis treatments. On the Eastern Shore of Maryland, the central venous catheter rates in the dialysis units averaged >45%. A multidisciplinary program was established with goals of decreasing catheter rates in order to decrease central line-associated bloodstream infections, decrease mortality associated with central line-associated bloodstream infection, decrease hospital days, and provide savings to the healthcare system. We collected the catheter rates within three dialysis centers served over a 5-year period. Using published data surrounding the incidence and related costs of central line-associated bloodstream infection and mortality per catheter day, the number of central line-associated bloodstream infection events, the costs, and the related mortality could be determined prior to and after the initiation of the dialysis access program. An organized dialysis access program resulted in a 82% decrease in the number of central venous catheter days which lead to a concurrent reduction in central line-associated bloodstream infection and deaths. As a result of creating an access program, central venous catheter rates decreased from an average rate of 45% to 8%. The cost savings related to the program was calculated to be over US$5 million. The decrease in the number of mortalities is estimated to be between 13 and 27 patients. We conclude that a formalized access program decreases catheter rates, central line-associated bloodstream infection, and the resultant hospitalizations, mortality, and costs. Areas with high hemodialysis catheter rates should develop access programs to better serve their patient population.

  19. Accuracy of chest radiography for positioning of the umbilical venous catheter.

    PubMed

    Guimarães, Adriana F M; Souza, Aline A C G de; Bouzada, Maria Cândida F; Meira, Zilda M A

    To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks - diaphragm, cardiac silhouette, and vertebral bodies - in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Of the 162 newborns assessed by echocardiography, only 44 (27.16%) had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33%) newborns, in the right atrium in 26 (16.05%), intra-hepatic in 37 (22.84%), and intra-aortic in-one newborn (0.62%). The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  20. Mapping and isolation of the pulmonary veins using the PVAC catheter.

    PubMed

    Duytschaever, Mattias; Anne, Wim; Papiashvili, Giorgi; Vandekerckhove, Yves; Tavernier, Rene

    2010-02-01

    We aimed to investigate the feasibility, efficacy, and safety of the pulmonary vein ablation catheter (PVAC) catheter (a novel multielectrode catheter using duty-cycled bipolar and unipolar radiofrequency energy, Medtronic, Minneapolis, MN, USA) to completely isolate the pulmonary veins (PVs). Twenty-seven patients (60 +/- 8 years) with paroxysmal atrial fibrillation (AF) underwent PV isolation with the PVAC catheter. PVAC was used for both mapping and isolation of the PVs (PVAC-guided ablation). After PVAC ablation, presence/absence of PV potentials (PVP) was verified using a conventional circular mapping catheter. In case of residual PVP on the circular catheter, PVAC ablation was continued. After PVAC-guided ablation 99 of 106 PVs (93%) and 21 of 27 patients (78%) were proven to be isolated. Failure to isolate was due to a mapping failure in four right-sided PVs and a true ablation failure in three right-sided PVs. After continued PVAC ablation, 103 of 106 PVs (97%) and 25 of 27 patients (93%) were shown to be isolated. The total procedural time from femoral vein access to complete catheter withdrawal was 176 +/- 25 minutes. The actual dwelling-time of the PVAC within the left atrium was 102 +/- 37 minutes. Esophageal T degrees rise to >38.5 degrees occurred in nine of 19 monitored patients (47%). (1) PVAC-guided ablation (i.e., mapping and ablation with a single catheter) results in isolation of all PVs in 73% of the patients. (2) An additional circular mapping catheter is required to increase complete isolation rate to 93% of the patients. (3) Given the esophageal T degrees rise in almost 50% of patients, safety precautions are needed.

  1. Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom.

    PubMed

    Tavallaei, M A; Lavdas, M K; Gelman, D; Drangova, M

    2016-08-01

    To facilitate MRI-guided catheterization procedures, we present an MRI-compatible remote catheter navigation system that allows remote navigation of steerable catheters with 3 degrees of freedom. The system consists of a user interface (master), a robot (slave), and an ultrasonic motor control servomechanism. The interventionalist applies conventional motions (axial, radial and plunger manipulations) on an input catheter in the master unit; this user input is measured and used by the servomechanism to control a compact catheter manipulating robot, such that it replicates the interventionalist's input motion on the patient catheter. The performance of the system was evaluated in terms of MRI compatibility (SNR and artifact), feasibility of remote navigation under real-time MRI guidance, and motion replication accuracy. Real-time MRI experiments demonstrated that catheter was successfully navigated remotely to desired target references in all 3 degrees of freedom. The system had an absolute value error of [Formula: see text]1 mm in axial catheter motion replication over 30 mm of travel and [Formula: see text] for radial catheter motion replication over [Formula: see text]. The worst case SNR drop was observed to be [Formula: see text]3 %; the robot did not introduce any artifacts in the MR images. An MRI-compatible compact remote catheter navigation system has been developed that allows remote navigation of steerable catheters with 3 degrees of freedom. The proposed system allows for safe and accurate remote catheter navigation, within conventional closed-bore scanners, without degrading MR image quality.

  2. Empyema and effusion: outcome of image-guided small-bore catheter drainage.

    PubMed

    Keeling, A N; Leong, S; Logan, P M; Lee, M J

    2008-01-01

    Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema.

  3. Between the lines: The 50th anniversary of long-term central venous catheters.

    PubMed

    Gow, Kenneth W; Tapper, David; Hickman, Robert O

    2017-05-01

    Tunneled central venous catheters (CVC) were developed five decades ago. Since then, several clinician-inventors have created a variety of catheters with different functions. Indeed, many catheters have been named after their inventor. Many have wondered who the inventors were of each catheter, and what specifically inspired their inventions. Many of these compelling stories have yet to be told. A literature review of common catheters and personal communication with inventors. Only first person accounts from inventors or those close to the invention were used. CVCs are now essential devices that have saved countless lives. Though the inventors have earned the honor of naming their catheters, it may be reasonable to consider more consistent terminology to describe these catheters to avoid confusion. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The role of laparoscopic surgery in the management of a malfunctioning peritoneal catheter.

    PubMed

    Alabi, A; Dholakia, S; Ablorsu, E

    2014-11-01

    Peritoneal catheter malfunction is a common complication of peritoneal dialysis (PD). It has a high failure rate with conservative management. Catheter replacement was historically the standard surgical treatment of choice. Nowadays, laparoscopy has been introduced as an alternative surgical modality to rescue the malfunctioning peritoneal catheter and also offers the possibility of replacement if indicated. The aim of this study was to compare the outcomes of these two surgical modalities. The medical records of consecutive patients who underwent surgical treatment for malfunctioning PD catheters (between January 2010 and April 2013) were analysed. The primary outcome included successful return to adequate PD. The secondary endpoint was length of catheter patency and the cause of catheter failure. A total of 32 cases were identified, of which 8 had open catheter replacement and 24 had a laparoscopic intervention. The overall median follow-up duration was 12.5 months. The success rate for laparoscopic surgery in terms of functioning catheter at 12 months was 62.5% but only 37.5% for open surgery. The mean length of catheter patency after laparoscopic intervention was 31.6 months compared with only 13.6 months for the open surgery group. The most common cause of catheter failure diagnosed during laparoscopic intervention was catheter migration (33.0%), followed by omental wrap and catheter blockage by fibrin/blood plug (25.0% each). Open surgery did not have any diagnostic potential. Laparoscopy is the treatment of choice for malfunctioning PD. Its proven benefit includes simultaneous identification of the aetiological cause of malfunction together with direct correction of this problem, thereby maximising outcome. It also allows for rapid recommencement of PD and avoidance of haemodialysis, saving cost and resources.

  5. A comparative assessment of irrigation and drainage characteristics for commercially available urethral catheters

    PubMed Central

    Davis, Niall F.; McMahon, Barry P.; Walsh, Michael; McDermott, Thomas E.D.; Thornhill, John A.; Manecksha, Rustom P.

    2017-01-01

    Introduction We aimed to investigate irrigation and drainage characteristics of commercially available urethral catheters and determined which catheter offers the best flow characteristics. Material and methods Twelve different commercially available urethral catheters from three companies (Bard™, Rusch™ and Dover™) were investigated to compare their irrigation and drainage properties. Irrigation port, drainage port and overall cross-sectional areas for a 24Fr 3-way catheter was measured and compared. The maximum (Qmax) and average (Qavg) irrigation and drainage flow rates for each catheter was measured for 20–40 seconds using uroflowmetry. The primary endpoint was to determine which catheter offers optimal irrigation and drainage parameters. Results Overall cross-sectional area, irrigation port cross-sectional area, and drainage port cross-sectional area differed significantly for each 24Fr 3-way catheter assessed (p <0.001). The 24Fr 3-way Rusch Simplastic™ catheter consistently demonstrated the greatest maximal flow rate (Qmax: 5 ±0.3 ml/s) and average flow rate (Qavg: 4.6 ±0.2 ml/s) for irrigation. The 24Fr 3-way Dover™ catheter provided the greatest drainage properties (Qmax: 19.7 ±2 ml/s; Q avg: 15.9 ±5 ml/s). In the setting of continuous bladder irrigation, the 24Fr 3-way Rusch Simplastic™ catheter provided the highest irrigation rates (Qmax: 6.6 ±1.8 ml/s; Q avg: 4.6 ±0.9 ml/s). Conclusions Three-way catheters demonstrate significant differences in their irrigation and drainage characteristics. The type of catheter selected should be based on the appropriate prioritization of efficient bladder irrigation versus efficient bladder drainage. PMID:29410890

  6. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions

    PubMed Central

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-01-01

    Patient: Male, 69 Final Diagnosis: Atherosclerotic renal artery stenosis Symptoms: None Medication: — Clinical Procedure: — Specialty: Radiology Objective: Unusual setting of medical care Background: The GuideLiner catheter extension device is a monorail-type “Child” support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). Case Report: We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guide-wires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. Conclusions: The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion. PMID:28533503

  7. Changing concepts in long-term central venous access: catheter selection and cost savings.

    PubMed

    Horattas, M C; Trupiano, J; Hopkins, S; Pasini, D; Martino, C; Murty, A

    2001-02-01

    Long-term central venous access is becoming an increasingly important component of health care today. Long-term central venous access is important therapeutically for a multitude of reasons, including the administration of chemotherapy, antibiotics, and total parenteral nutrition. Central venous access can be established in a variety of ways varying from catheters inserted at the bedside to surgically placed ports. Furthermore, in an effort to control costs, many traditionally inpatient therapies have moved to an outpatient setting. This raises many questions regarding catheter selection. Which catheter will result in the best outcome at the least cost? It has become apparent in our hospital that traditionally placed surgical catheters (ie, Hickmans and central venous ports) may no longer be the only options. The objective of this study was to explore the various modalities for establishing central venous access comparing indications, costs, and complications to guide the clinician in choosing the appropriate catheter with the best outcome at the least cost. We evaluated our institution's central venous catheter use during a 3-year period from 1995 through 1997. Data was obtained retrospectively through chart review. In addition to demographic data, specific information regarding catheter type, placement technique, indications, complications, and catheter history were recorded. Cost data were obtained from several departments including surgery, radiology, nursing, anesthesia, pharmacy, and the hospital purchasing department. During a 30-month period, 684 attempted central venous catheter insertions were identified, including 126 surgically placed central venous catheters, 264 peripherally inserted central catheters by the nursing service, and 294 radiologically inserted peripheral ports. Overall complications were rare but tended to be more severe in the surgical group. Relative cost differences between the groups were significant. Charges for peripherally inserted

  8. Review of advanced catheter technologies in radiation oncology brachytherapy procedures

    PubMed Central

    Zhou, Jun; Zamdborg, Leonid; Sebastian, Evelyn

    2015-01-01

    The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy procedures using magnetic resonance images and electromagnetic tracking. The accuracy of catheter reconstruction, imaging artifacts, and other notable properties of plastic and titanium applicators in gynecologic treatments are reviewed. The accuracy, noise performance, and limitations of electromagnetic tracking for catheter reconstruction are discussed. Several newly developed applicators for accelerated partial breast irradiation and gynecologic treatments are also reviewed. New hypofractionated high dose rate treatment schemes in prostate cancer and accelerated partial breast irradiation are presented. PMID:26203277

  9. Intraluminal laser speckle rheology using an omni-directional viewing catheter

    PubMed Central

    Wang, Jing; Hosoda, Masaki; Tshikudi, Diane M.; Hajjarian, Zeinab; Nadkarni, Seemantini K.

    2016-01-01

    A number of disease conditions in luminal organs are associated with alterations in tissue mechanical properties. Here, we report a new omni-directional viewing Laser Speckle Rheology (LSR) catheter for mapping the mechanical properties of luminal organs without the need for rotational motion. The LSR catheter incorporates multiple illumination fibers, an optical fiber bundle and a multi-faceted mirror to permit omni-directional viewing of the luminal wall. By retracting the catheter using a motor-drive assembly, cylindrical maps of tissue mechanical properties are reconstructed. Evaluation conducted in a test phantom with circumferentially-varying mechanical properties demonstrates the capability of the LSR catheter for the accurate mechanical assessment of luminal organs. PMID:28101407

  10. [Comparative study of PTFE grafts in forearm vs cuffed permanent catheters].

    PubMed

    Moyano, M J; Salgueira, M; Aresté, N; Escalera, B; del Toro, N; Jiménez-Víbora, E; Martínez-Puerto, A I; Molas, J R; Palma, A

    2006-01-01

    As is universally accepted the best form of permanent vascular access for haemodialysis is the native arteriovenous fistula. A second and third options are the politetrafluoroethylene (PTFE) AV grafts and the cuffed, tunneled, internal catheters. The overall performance and complications of catheters is clearly inferior to AV fistula. There are not many studies that compare permanent catheters to grafts in terms of functionality, survival and complications. We analyzed 81 vascular accesses carried out from october 99 to december 03 in 59 patients and during a follow-up period of 35 months. Two groups were considered. Group 1, catheters (n 42) and group 2, grafts (n 39). Clinical aspects, comorbidity index (Wright and Kanh), dialysis dose and complications and survival of the access were registered. Both groups were similar in age, sex, time on haemodialysis, number of previous accesses and hospitalization days. Cardiovascular morbidity and comorbidity index were significantly higher in patients with catheter. While blood flow during dialysis was higher in grafts both groups showed no significant differences in parameters of efficacy of dialysis (Kt/V, TAC BUN and PCRn). Serum albumin was lower in patients with catheter. The number of accesses that failed was higher in the graft group being thrombosis the main complication followed by infection. Kaplan-Meier curves showed better accumulated survival of permanent catheters versus grafts (61,4% vs 9,8% at 35 months). The most frequent complication of catheter was infection while in the case of grafts it was thrombosis followed by infection. Although they were placed in patients with higher comorbidity, cuffed, tunneled catheters showed less number of complications and better survival than PTFE grafts in our patients in haemodialysis. The main cause of failure of both vascular access was thrombosis followed by infection. The dose of dialysis obtained was no different in both groups. Cuffed, tunneled permanent catheters

  11. 21 CFR 880.5210 - Intravascular catheter securement device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular catheter securement device. 880.5210 Section 880.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... and is used to keep the hub of the needle or the catheter flat and securely anchored to the skin. (b...

  12. 21 CFR 880.5210 - Intravascular catheter securement device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intravascular catheter securement device. 880.5210 Section 880.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... and is used to keep the hub of the needle or the catheter flat and securely anchored to the skin. (b...

  13. Minimizing Hemodialysis Catheter Dysfunction: An Ounce of Prevention

    PubMed Central

    Lee, Timmy; Lok, Charmaine; Vazquez, Miguel; Moist, Louise; Maya, Ivan; Mokrzycki, Michele

    2012-01-01

    The maintenance of tunneled catheter (TC) patency is critical for the provision of adequate hemodialysis in patients who are TC-dependent. TC dysfunction results in the need for costly and inconvenient interventions, and reduced quality of life. Since the introduction of TCs in the late 1980s, heparin catheter lock has been the standard prophylactic regimen for the prevention of TC dysfunction. More recently, alternative catheter locking agents have emerged, and in some cases have shown to be superior to heparin lock with respect to improving TC patency and reducing TC-associated infections. These include citrate, tissue plasminogen activator, and a novel agent containing sodium citrate, methylene blue, methylparaben, and propylparaben. In addition, prophylaxis using oral anticoagulants/antiplatelet agents, including warfarin, aspirin, ticlodipine, as well as the use of modified heparin-coated catheters have also been studied for the prevention of TC dysfunction with variable results. The use of oral anticoagulants and/or antiplatelet agents as primary or secondary prevention of TC dysfunction must be weighed against their potential adverse effects, and should be individualized for each patient. PMID:22518310

  14. Clinical study of the Erlanger silver catheter--data management and biometry.

    PubMed

    Martus, P; Geis, C; Lugauer, S; Böswald, M; Guggenbichler, J P

    1999-01-01

    The clinical evaluation of venous catheters for catheter-induced infections must conform to a strict biometric methodology. The statistical planning of the study (target population, design, degree of blinding), data management (database design, definition of variables, coding), quality assurance (data inspection at several levels) and the biometric evaluation of the Erlanger silver catheter project are described. The three-step data flow included: 1) primary data from the hospital, 2) relational database, 3) files accessible for statistical evaluation. Two different statistical models were compared: analyzing the first catheter only of a patient in the analysis (independent data) and analyzing several catheters from the same patient (dependent data) by means of the generalized estimating equations (GEE) method. The main result of the study was based on the comparison of both statistical models.

  15. Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization.

    PubMed

    Qureshi, Adnan I; Xiao, WeiGang; Liu, HongLiang

    2015-10-01

    The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations.

  16. Modeling and estimation of tip contact force for steerable ablation catheters.

    PubMed

    Khoshnam, Mahta; Skanes, Allan C; Patel, Rajni V

    2015-05-01

    The efficacy of catheter-based cardiac ablation procedures can be significantly improved if real-time information is available concerning contact forces between the catheter tip and cardiac tissue. However, the widely used ablation catheters are not equipped for force sensing. This paper proposes a technique for estimating the contact forces without direct force measurements by studying the changes in the shape of the deflectable distal section of a conventional 7-Fr catheter (henceforth called the "deflectable distal shaft," the "deflectable shaft," or the "shaft" of the catheter) in different loading situations. First, the shaft curvature when the tip is moving in free space is studied and based on that, a kinematic model for the deflectable shaft in free space is proposed. In the next step, the shaft shape is analyzed in the case where the tip is in contact with the environment, and it is shown that the curvature of the deflectable shaft provides useful information about the loading status of the catheter and can be used to define an index for determining the range of contact forces exerted by the ablation tip. Experiments with two different steerable ablation catheters show that the defined index can detect the range of applied contact forces correctly in more than 80% of the cases. Based on the proposed technique, a framework for obtaining contact force information by using the shaft curvature at a limited number of points along the deflectable shaft is constructed. The proposed kinematic model and the force estimation technique can be implemented together to describe the catheter's behavior before contact, detect tip/tissue contact, and determine the range of contact forces. This study proves that the flexibility of the catheter's distal shaft provides a means of estimating the force exerted on tissue by the ablation tip.

  17. Retrieval of impacted broken balloon by balloon inflation in guiding catheter.

    PubMed

    Mehta, Vimal; Pandit, Bhagya Narayan; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay; Tyagi, Sanjay

    2014-07-01

    Broken catheter fragment in a coronary artery during percutaneous coronary angioplasty is a rare complication. It can result in serious problems as a result of thrombus formation and embolization of broken fragment. We report an unusual complication of a broken balloon catheter during angioplasty, which was successfully retrieved by balloon inflation in guiding catheter technique.

  18. Nurses' guide to early detection of umbilical arterial catheter complications in infants.

    PubMed

    Furdon, Susan Arana; Horgan, Michael J; Bradshaw, Wanda Todd; Clark, David A

    2006-10-01

    Umbilical arterial catheters (UAC) are routinely used in the care of critically ill newborns. Complications related to UACs include vascular compromise, hemorrhage, complications related to malposition, severance of the catheter itself, and infection. This article is Part II in a series dedicated to assessing infants with an umbilical catheter. Part I focused on infants with umbilical venous catheters; this article will focus on the physical assessment relevant to infants with an UAC. Complications related to UACs can occur during any phase of treatment: insertion, while indwelling, or after discontinuing the catheter. Review of clinical signs of complications along with clinical photographs, will assist caregivers in promptly recognizing UAC-related complications.

  19. Catheter design optimization for practical intravascular photoacoustic imaging (IVPA) of vulnerable plaques

    NASA Astrophysics Data System (ADS)

    Iskander-Rizk, Sophinese; Wu, Min; Springeling, Geert; Mastik, Frits; Beurskens, Robert H. S. H.; van der Steen, Antonius F. W.; van Soest, Gijs

    2018-02-01

    Intravascular photoacoustic/ultrasound imaging (IVPA/US) can image the structure and composition of atherosclerotic lesions identifying lipid-rich plaques ex vivo and in vivo. In the literature, multiple IVPA/US catheter designs were presented and validated both in ex-vivo models and preclinical in-vivo situations. Since the catheter is a critical component of the imaging system, we discuss here a catheter design oriented to imaging plaque in a realistic and translatable setting. We present a catheter optimized for light delivery, manageable flush parameters and robustness with reduced mechanical damage risks at the laser/catheter joint interface. We also show capability of imaging within sheath and in water medium.

  20. Long-term outcome of permanent hemodialysis catheters: a controlled study.

    PubMed

    Jean, G; Charra, B; Chazot, C; Vanel, T; Terrat, J C; Hurot, J M

    2001-01-01

    Hemodialysis tunneled catheters are widely used nowadays. However, their complications, infection and dysfunction, remain much too frequent. Different types of tunneled silicone hemodialysis catheters are available. We prospectively compared the long-term outcome of the two most popular devices, Permcath cuffed double catheter and TwinCath uncuffed twin catheter, both inserted percutaneously. From January 1994 to April 1998, 125 tunneled catheters were inserted in the internal jugular vein of 86 chronic hemodialysis patients, 63 TwinCath MedComp (TC) and 62 Permcath Quinton (PC). They were prospectively followed looking for technical patency, infection and dysfunction rate. TC were used more often for iterative access (52 vs. 25%, p = 0.01) and were inserted more frequently in the left internal jugular vein (59 vs. 16% p < 0.001). Their median technical survival rate was longer (869 vs. 433 days for PC, p < 0.01) with a 1-year patency rate of 80 vs. 53% (p = 0.002). Total catheter extrusion was also slightly less frequent with TC (4.7 vs. 9.6%), but partial extrusion happened more frequently (43 vs. 16%, p = 0.02). No significant difference in infection rate was observed, 0.77 for TC vs. 1.3 local infection/1,000 catheter days; 1.08 vs. 1.30 bacteremia/1,000 catheter days. A persistent catheter thrombosis was observed in 7.9 vs. 20.9% in PC (p = 0.04), the number of dysfunction was 10.5 vs. 24/1,000 days in use (p = 0.0001) and the number of urokinase infusion was 4.4 vs. 12/1,000 days (p = 0.001). PC needed more radiological interventions for dysfunction with endolumenal brushes (4 vs. 0) or fibrin sleeve removal (4 vs. 0). The vena cava thrombosis incidence was not different (2 vs. 3). Although the study was not randomized, TC appears more efficient allowing for a longer patency with a lower dysfunction rate than PC. This was reinforced by less favorable conditions of TC including more left jugular side and more iterative catheters. The cuff does not offer a

  1. Comparative effects of 12 weeks of equipment based and mat Pilates in patients with Chronic Low Back Pain on pain, function and transversus abdominis activation. A randomized controlled trial.

    PubMed

    Cruz-Díaz, David; Bergamin, M; Gobbo, S; Martínez-Amat, Antonio; Hita-Contreras, Fidel

    2017-08-01

    Pilates method has been recommended for patients with chronic low back pain (CLBP) and the activation of transversus abdominis has been deemed to play an important role in the improvement of these patients. Nevertheless, the evidence of the activation of TrA in Pilates practitioners remains unclear. To assess the effectiveness of 12 weeks of Pilates practice in disability, pain, kinesiophobia and transversus abdominis activation in patients with chronic nonspecific Low Back Pain. A randomized controlled trial was carried out. A single-blind randomized controlled trial with repeated measures at 6 and 12 weeks was carried out. A total of ninety eight patients with low back pain were included and randomly allocated to a Pilates Mat group (PMG) equipment based with apparatus Pilates (PAG) or control group (CG). Roland Morris Disability Questionnaire (RMDQ), visual analog scale (VAS) Tampa Scale of Kinesiophobia (TSK), and transversus abdominis (TrA) activation assessed by real time ultrasound measurement (US) were assessed as outcome measures. Improvement were observed in both intervention groups in all the included variables at 6 and 12 weeks (p<0.001). Faster enhancement was observed in the equipment based Pilates group (p=0.007). Equipment based and mat Pilates modalities are both effective in the improvement of TaA activation in patients with CLBP with associate improvement on pain, function and kinesiophobia. Significant differences were observed after 12 weeks of intervention in PMG and PAG with faster improvement in PAG suggesting that, feedback provided by equipment could help in the interiorization of Pilates principles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    PubMed

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  3. Longer Duration of Urinary Catheterization Increases Catheter-Associated Urinary Tract Infection in PICU.

    PubMed

    Fukuoka, Kahoru; Furuichi, Mihoko; Ito, Kenta; Morikawa, Yoshihiko; Watanabe, Ichiro; Shimizu, Naoki; Horikoshi, Yuho

    2018-06-13

    Catheter-associated urinary tract infections account for 30% of healthcare-associated infections. To date, few studies have addressed pediatric catheter-associated urinary tract infection in PICUs. The aim of our study was to assess the risk of catheter-associated urinary tract infection in relation to the duration of catheterization in the PICU. Retrospective cohort study. PICU at a tertiary children's hospital. Our study was conducted between April 2012 and June 2015 at Tokyo Metropolitan Children's Medical Center in Japan. Children in the PICU with an urethral catheter were included. Catheter-associated urinary tract infection cases were defined according to the National Healthcare Safety Network criteria. The patients' demographic data and isolated organisms were reviewed. Duration of catheterization and the catheter-associated urinary tract infection occurrence rate were analyzed. None. Among 1,890 catheterizations, 23 catheter-associated urinary tract infection cases were identified. The overall occurrence rate was 2.35/1,000 catheter-days. Among the patients with catheter-associated urinary tract infection, 13 were boys. The median age was 11 months (interquartile range, 7-35 mo), and the median duration of catheterization was 7 days (interquartile range, 5-12 d). The isolated bacteria were Escherichia coli (26.5%), Enterococcus faecalis (17.6%), and Klebsiella pneumoniae (11.8%). Two species were isolated in each of 11 cases (47.8%). Each additional day of catheterization increased the risk of catheter-associated urinary tract infection (odds ratio, 1.06; 95% CI, 1.02-1.10, and odds ratio adjusted for contact precaution status and surgical procedures was 1.05; 95% CI, 1.01-1.09). Longer duration of catheterization increased the risk of catheter-associated urinary tract infection by 5% each day at the PICU. Prompt removal of the urethral catheter is strongly recommended whenever feasible.

  4. Reinnervation following catheter-based radio-frequency renal denervation.

    PubMed

    Booth, Lindsea C; Nishi, Erika E; Yao, Song T; Ramchandra, Rohit; Lambert, Gavin W; Schlaich, Markus P; May, Clive N

    2015-04-20

    What is the topic of this review? Does catheter-based renal denervation effectively denervate the afferent and efferent renal nerves and does reinnervation occur? What advances does it highlight? Following catheter-based renal denervation, the afferent and efferent responses to electrical stimulation were abolished, renal sympathetic nerve activity was absent, and levels of renal noradrenaline and immunohistochemistry for tyrosine hydroxylase and calcitonin gene-related peptide were significantly reduced. By 11 months after renal denervation, both the functional responses and anatomical markers of afferent and efferent renal nerves had returned to normal, indicating reinnervation. Renal denervation reduces blood pressure in animals with experimental hypertension and, recently, catheter-based renal denervation was shown to cause a prolonged decrease in blood pressure in patients with resistant hypertension. The randomized, sham-controlled Symplicity HTN-3 trial failed to meet its primary efficacy end-point, but there is evidence that renal denervation was incomplete in many patients. Currently, there is little information regarding the effectiveness of catheter-based renal denervation and the extent of reinnervation. We assessed the effectiveness of renal nerve denervation with the Symplicity Flex catheter and the functional and anatomical reinnervation at 5.5 and 11 months postdenervation. In anaesthetized, non-denervated sheep, there was a high level of renal sympathetic nerve activity, and electrical stimulation of the renal nerve increased blood pressure and reduced heart rate (afferent response) and caused renal vasoconstriction and reduced renal blood flow (efferent response). Immediately after renal denervation, renal sympathetic nerve activity and the responses to electrical stimulation were absent, indicating effective denervation. By 11 months after denervation, renal sympathetic nerve activity was present and the responses to electrical stimulation

  5. Complete resection of a rectus abdominis muscle invaded by desmoid tumors and subsequent management with an abdominal binder: a case report.

    PubMed

    Ogawa, Tatsuhiko

    2018-02-07

    Desmoid-type fibromatosis is characterized by desmoid tumors, which are benign soft tissue tumors that can be locally aggressive but typically do not metastasize. Desmoid tumors can manifest anywhere in the body, and those in the abdominal cavity account for approximately 30 to 50% of all such tumors. Complete resection with free margins has been the standard treatment, but non-surgical therapies have been implemented recently. However, if tumors are strongly invasive and/or persistently recur, radical surgical resection with free margins remains the primary treatment. Unfortunately, radical resection may cause large abdominal defects and hinder reconstruction. Several reports and recommendations have addressed this issue; however, to the best of our knowledge, few reports have described complete resection and the subsequent reconstruction of the rectus abdominis muscle. A 35-year-old Asian woman presented at our hospital with a chief complaint of abdominal pain. She had abdominal desmoid tumors that required complete resection of her rectus abdominis muscle. Due to necrosis in her own reconstructed tissue, we failed to cover her anterior abdominal wall; thus, we used an abdominal binder as a substitute material to avoid exacerbating the incisional hernia and help her generate intra-abdominal pressure. This case report may be informative and helpful for the treatment of patients with desmoid tumors, as managing desmoid-type fibromatosis is difficult.

  6. Extensive Chest Wall Tissue Loss and its Management by Vertical Rectus Abdominis Myocutaneous Flap

    PubMed Central

    Basu, Sandip Kanti; Bain, Jayanta; Chattopadhyay, Debarati; Majumdar, Bijay Kumar

    2017-01-01

    Extensive electric burn around the chest in children is rare and this type of injury always poses a great challenge for its management. A 12-year-old male child with extensive electric burn of the chest wall was admitted to hospital. It was a neglected case of 9 days old burn; the young boy was in critical condition having systemic features of toxemia with widespread necrosis of the skin, subcutaneous tissues, and muscles along with exposed bones (ribs and sternum) with the risk of impending rupture of pleura through the exposed intercostal spaces. After initial resuscitation, a thorough debridement of all necrotic tissues was done. Thereafter, a superiorly based vertical rectus abdominis myocutaneous flap was harvested to cover the exposed bones and intercostal spaces. The remaining raw areas were skin grafted. The child made an excellent recovery with good outcome. PMID:28082777

  7. [Coronary angioplasty with the Monorail system via 6 French diagnostic catheters].

    PubMed

    Villavicencio, R; González, H; López, J; Zavala, E; Ban Hayashi, E B; Gaspar, J; Gil, M; Martínez Ríos, M A

    1994-01-01

    We studied the use of "Monorail" system with Express (Scimed) balloon catheters for coronary angioplasty through 6 French (F) "high-flow" diagnostic catheters (Novoste, USCI). Prospectively, from July 1992 to January 1993, angioplasty of 31 lesions in 24 patients was attempted (1.3 lesions/procedure). Twenty procedures were of a single lesion and four were multi-vessel angioplasty. Fourteen lesions were in the left anterior descending or in its branches, 10 in the left circumflex or in its branches, 6 in the right coronary artery, and one in the distal anastomosis of an internal mammary artery graft. Thirteen lesions (42%) were type A, 17 (55%) type B and one (3%) type C. Balloon sizes varied between 2.0 and 3.5 mm. Twenty-nine lesions could be successfully dilated (93.5%); two cases were unsuccessful due to an acute occlusion in one and residual stenosis of more than 50% in the other. For only one case, another balloon catheter different from the "Monorail" system was necessary to complete a multi-vessel angioplasty. Coronary visualization and manipulation of the balloon through the tip of the diagnostic catheter were satisfactory in all cases, except with the 3.5 mm balloon catheter. Coronary angioplasty with "Monorail" system balloon catheters through 6 F "high-flow" diagnostic catheters is feasible and provides a high success rate in simple and moderately complex selected lesions, including multivessel angioplasty with advantages of smaller artery punction and the feasibility of performing coronary angioplasty with the same catheter used for diagnostic angiography.

  8. Catheter-Associated Rhodotorula mucilaginosa Fungemia in an Immunocompetent Host

    PubMed Central

    Kim, Hyun Ah; Hyun, Miri

    2013-01-01

    Rhodotorula species live in the environment, but can also colonize human epithelium, as well as respiratory, and gastrointestinal tracts. Reports of infection, especially in the past 2 decades, have noted increasing numbers of Rhodotorula infections, particularly in immunocompromised hosts, leading it to be considered emerging opportunistic pathogen. The major risk factors for infection were prolonged use of central venous catheters in patients with hematological and solid malignancies who are taking corticosteroids or cytotoxic drugs. Herein, we report a case of catheter-associated fungemia due to R. mucilaginosa in an immunocompetent host. The patient was admitted to the intensive care unit with mechanical ventilation for treatment of community-acquired pneumonia. After 10 days, the patient developed new-onset fever confirmed to be a result of catheter-associated blood-stream infection by R. mucilaginosa. It was successfully treated by catheter removal and intravenous amphotericin B. PMID:24396637

  9. Catheter tracking in an interventional photoacoustic surgical system

    NASA Astrophysics Data System (ADS)

    Cheng, Alexis; Itsarachaiyot, Yuttana; Kim, Younsu; Zhang, Haichong K.; Taylor, Russell H.; Boctor, Emad M.

    2017-03-01

    In laparoscopic medical procedures, accurate tracking of interventional tools such as catheters are necessary. Current practice for tracking catheters often involve using fluoroscopy, which is best avoided to minimize radiation dose to the patient and the surgical team. Photoacoustic imaging is an emerging imaging modality that can be used for this purpose and does not currently have a general tool tracking solution. Photoacoustic-based catheter tracking would increase its attractiveness, by providing both an imaging and tracking solution. We present a catheter tracking method based on the photoacoustic effect. Photoacoustic markers are simultaneously observed by a stereo camera as well as a piezoelectric element attached to the tip of a catheter. The signals received by the piezoelectric element can be used to compute its position relative to the photoacoustic markers using multilateration. This combined information can be processed to localize the position of the piezoelectric element with respect to the stereo camera system. We presented the methods to enable this work and demonstrated precisions of 1-3mm and a relative accuracy of less than 4% in four independent locations, which are comparable to conventional systems. In addition, we also showed in another experiment a reconstruction precision up to 0.4mm and an estimated accuracy up to 0.5mm. Future work will include simulations to better evaluate this method and its challenges and the development of concurrent photoacoustic marker projection and its associated methods.

  10. Initial experience with the Europass: a new ultra-low profile monorail balloon catheter.

    PubMed

    Zimarino, M; Corcos, T; Favereau, X; Tamburino, C; Toussaint, M; Spaulding, C; Guérin, Y

    1994-09-01

    One of the causes for percutaneous transluminal coronary angioplasty (PTCA) failure is the inability to cross the lesion with the balloon catheter after guidewire positioning. The Europass coronary angioplasty catheter is a monorail Duralyn balloon catheter developed to enhance lesion crossability and to overcome this limitation. This system was evaluated in 50 patients in which target lesions were chronic total coronary occlusions (12 cases) or stenoses that could not be reached or crossed by other new monorail balloon catheters. Overall procedural success was obtained in 49/50 patients (98%), using a single Europass balloon catheter in 46/50 patients (92%), with no in-hospital complications. Its low profile, small distal shaft, and excellent trackability allowed successful angioplasty in cases where other catheters failed. This balloon catheter represents a significant advance in angioplasty technology and can be considered as a first-choice device for a safe and expeditious single-operator procedure.

  11. Evaluation of epidural and peripheral nerve catheter heating during magnetic resonance imaging.

    PubMed

    Owens, Sean; Erturk, M Arcan; Ouanes, Jean-Pierre P; Murphy, Jamie D; Wu, Christopher L; Bottomley, Paul A

    2014-01-01

    Many epidural and peripheral nerve catheters contain conducting wire that could heat during magnetic resonance imaging (MRI), requiring removal for scanning. We tested 2 each of 6 brands of regional analgesia catheters (from Arrow International [Reading, Pennsylvania], B. Braun Medical Inc [Bethlehem, Pennsylvania], and Smiths Medical/Portex [Keene, New Hampshire]) for exposure to clinical 1.5- and 3-T MRI. Catheters testing as nonmagnetic were placed in an epidural configuration in a standard human torso-sized phantom, and an MRI pulse sequence applied at the maximum scanner-allowed radiofrequency specific absorption rate (SAR) for 15 minutes. Temperature and SAR exposure were sampled during MRI using multiple fiberoptic temperature sensors. Two catheters (the Arrow StimuCath Peripheral Nerve and B. Braun Medical Perifix FX Epidural) were found to be magnetic and not tested further. At 3 T, exposure of the remaining 3 epidural and 1 peripheral nerve catheter to the scanner's maximum RF exposure elicited anomalous heating of 4°C to 7°C in 2 Arrow Epidural (MultiPort and Flex-Tip Plus) catheters at the entry points. Temperature increases for the other catheters at 3 T, and all catheters at 1.5 T were 1.4°C or less. When normalized to the body-average US Food and Drug Administration guideline SAR of 4 W/kg, maximum projected temperature increases were 0.1°C to 2.5°C at 1.5 T and 0.7°C to 2.7°C at 3 T, except for the Arrow MultiPort Flex-Tip Plus catheter at 3 T whose increase was 14°C. Most but not all catheters can be left in place during 1.5-T MRI scans. Heating of less than 3°C during MRI for most catheters is not expected to be injurious. While heating was lower at 1.5 T versus 3 T, performance differences between products underscore the need for safety testing before performing MRI.

  12. Evaluation of Epidural and Peripheral Nerve Catheter Heating During Magnetic Resonance Imaging

    PubMed Central

    Owens, Sean; Erturk, M. Arcan; Ouanes, Jean-Pierre P.; Murphy, Jamie D.; Wu, Christopher L.; Bottomley, Paul A.

    2014-01-01

    Background Many epidural and peripheral nerve catheters contain conducting wire that could heat during magnetic resonance imaging (MRI), requiring removal for scanning. Methods We tested 2 each of 6 brands of regional analgesia catheters (from Arrow International, B. Braun Medical, and Smiths Medical/Portex) for exposure to clinical 1.5 and 3 Tesla (T) MRI. Catheters testing as non-magnetic were placed in an epidural configuration in a standard human torso-sized phantom, and an MRI pulse sequence applied at the maximum scanner-allowed radio frequency (RF) specific absorption rate (SAR) for 15 minutes Temperature and SAR exposure were sampled during MRI using multiple fiber-optic temperature sensors. Results Two catheters (the Arrow StimuCath Peripheral Nerve, and Braun Medical Perifix FX Epidural) were found to be magnetic and not tested further. At 3T, exposure of the remaining 3 epidural and 1 peripheral nerve catheter to the scanner’s maximum RF exposure, elicited anomalous heating of 4 to 7°C in 2 Arrow Epidural (MultiPort and Flex-Tip Plus) catheters at the entry points. Temperature increases for the other catheters at 3T and all catheters at 1.5T were ≤1.4°C. When normalized to the body-average FDA guideline SAR of 4W/kg, maximum projected temperature increases were 0.1 to 2.5°C at 1.5T and 0.7 to 2.7°C at 3T, except for the Arrow MultiPort Flex-Tip Plus catheter at 3T whose increase was 14°C. Conclusions Most but not all catheters can be left in place during 1.5T MRI scans. Heating of <3°C during MRI for most catheters is not expected to be injurious. While heating was lower at 1.5T vs 3T, performance differences between products underscore the need for safety testing before performing MRI. PMID:25275576

  13. Risk Factors for Catheter Associated Urinary Tract Infections in a Pediatric Institution.

    PubMed

    Lee, Nora G; Marchalik, Daniel; Lipsky, Andrew; Rushton, H Gil; Pohl, Hans G; Song, Xiaoyan

    2016-04-01

    Catheter associated urinary tract infections are an essential measure for health care quality improvement that affects reimbursement through hospital acquired condition reduction programs in adult patients. With the mounting importance of preventing such infections we evaluated risk factors for acquiring catheter associated urinary tract infections in pediatric patients. All catheter associated urinary tract infections were identified at 1 pediatric institution from September 2010 to August 2014 from a prospective database maintained by the infection control office. To identify risk factors patients with a catheter associated urinary tract infection were individually matched to control patients with a urinary catheter but without infection by age, gender, date and the hospital location of the infection in 1:2 fashion. A total of 50 patients with catheter associated urinary tract infection were identified and matched to 100 control patients. Compared to controls the patients with infection were more likely to have a catheter in place for longer (2.9 days, OR 1.08, 95% CI 1.01, 1.15, p = 0.02). They were also more likely to be on contact precautions (OR 4.00, 95% CI 1.73, 9.26, p = 0.001), and have concurrent infections (OR 3.04, 95% CI 1.39, 6.28, p = 0.005) and a history of catheterization (OR 3.24, 95% CI 1.55, 6.77, p = 0.002). Using a conditional multivariate regression model the 3 most predictive variables were duration of catheter drainage, contact isolation status and history of catheterization. Longer duration of urinary catheter drainage, positive contact precautions status and a history of catheterization appear to be associated with a higher risk of catheter associated urinary tract infection in hospitalized pediatric patients. Physicians should attempt to decrease the duration of catheterization, especially in patients who meet these criteria, to minimize the risk of catheter associated urinary tract infection. Copyright © 2016 American Urological

  14. Central venous catheter - flushing

    MedlinePlus

    ... on a pair of sterile gloves. Remove the cap on the saline syringe and set the cap down on the paper towel. DO NOT let ... It is a good idea to change the caps at the end of your catheter (called the " ...

  15. Attitudes and knowledge of urethral catheters: a targeted educational intervention.

    PubMed

    Cohen, Andrew; Nottingham, Charles; Packiam, Vignesh; Jaskowiak, Nora; Gundeti, Mohan

    2016-10-01

    To assess the training of medical students and their confidence in urethral catheter placement, given growing evidence of unnecessary urology consults and iatrogenic injury. A third-year medical school class was queried about their attitudes and knowledge of catheter placement before and after the Clinical Biennium. The Clinical Biennium introduces hands-on skills prior to clinical clerkships. Urethral catheterisation is one of the skill stations that students rotate through, and urology residents provide a didactic session and supervised simulation. Confidence was self-rated regarding catheter technique, knowledge, troubleshooting, and comfort with placement in the same and opposite gender. Factual questions were posed about proper insertion and malfunctioning catheters. In all, 92 students participated in the initial survey, 41% female and 59% male, and 87% of the students had never placed a catheter. Students desired high confidence in catheter skills (4.4/5). There were no significant differences in responses for those with a desire to pursue urology vs other specialties, or procedural fields compared with non-procedural fields. Prior independent learning was reported by 38% of students and was a predictor for increased confidence across all domains (P < 0.05). In all, 16.7% of students initially identified proper male urethral insertion distance, which improved to 95.6% after the session. Student interest in urology modestly increased after the educational session (P = 0.028). At 3-6 months follow-up, students had performed a median (interquartile range) of 4 (2-7) urethral catheter placements, and 74.2% of students rated training useful or extremely useful. Indeed, 54.8% desired more instruction. Knowledge assessment indicated that 93% of students retained comprehension of proper male urethral insertion distance. Clinical Foley training rarely contradicted instruction from the Clinical Biennium (6.5%). At all time-points, medical student knowledge for

  16. Catheter port cleansing techniques and the entry of povidone-iodine into the epidural space.

    PubMed

    Paice, J A; DuPen, A; Schwertz, D

    1999-04-01

    To determine whether three epidural catheter port cleansing techniques used to apply a povidone-iodine solution differed with respect to the introduction of this solution through the epidural catheter. Experimental. Laboratory. Five DuPen (Davol, Cranston, RI) epidural catheters. Five DuPen epidural catheters each were cleansed twice with (a) a commercially available 10% povidone-iodine swabstick, (b) a commercially available pledget impregnated with 10% povidone-iodine, and (c) a gauze pad saturated with 10% povidone-iodine. The order of cleansing was randomized. Each solution was used to clean the port for 30 seconds, and the port was allowed to dry for 30 seconds, similar to the technique used in the clinical setting. After cleaning the catheter port, water was injected through the catheter, and the solution from the tip of the catheter was analyzed using absorbance spectrophotometry. Cleansing techniques, presence of povidone-iodine in catheter. A statistically significant difference existed between the three cleansing techniques, with the pledget yielding the lowest values of povidone-iodine contamination of the epidural catheter (Freidman test, p = 0.02). Use of pledgets allowed the least amount of povidone-iodine to enter the epidural catheter as compared with the swabsticks or gauze pads. Commercially available pledgets used to cleanse catheter injection ports may limit the introduction of 10% povidone-iodine into the epidural or intrathecal space.

  17. A 6-Fr Guiding Catheter (Slim Guide®) for Use with Multiple Microdevices

    PubMed Central

    Kai, Y.; Ohmori, Y.; Watanabe, M.; Kaku, Y.; Morioka, M.; Hirano, T.; Yano, S.; Kawano, T.; Hamada, J-I.; Kuratsu, J-I.

    2013-01-01

    Summary A modified technique is required in patients with wide-necked aneurysms whose treatment by the single microcatheter technique is difficult. We developed a 6-Fr guiding catheter (Slim Guide®) that features a large lumen (0.072 inch) for performing the modified technique. To evaluate the usefulness of Slim Guide® we carried out experiments using three types of 6-Fr guiding catheter. In experiment 1, the shaft hardness and kink resistance were compared among three different guiding catheters (Slim Guide®, Launcher®, Envoy®). In experiment 2, we inserted a microballoon catheter and a microcatheter into the three different guiding catheters and recorded the maximal infusion pressure. In experiment 3, we inserted 13 different types of microdevices into the three different guiding catheters and evaluated the resistance of the microdevices. Although the shaft of the Slim Guide® was softer than that of the other two guiding catheters, its kink resistance was comparable. The maximal infusion pressure was significantly lower than with Launcher® or Envoy® catheters. Furthermore, with Slim Guide®, in 136 of 143 microdevice combinations examined (95.1%) there was no resistance; this was true for 125 (87.4%) and 116 (81.1%) combinations using the Launcher® - and the Envoy® guiding catheters, respectively. There was a significant difference between Slim Guide® and the other two guiding catheters with respect to their accommodation of double microsystems (p<0.05). Although the inner diameter of Slim Guide® is slightly larger than of the other two guiding catheters, it significantly increased the combination of microdevices that could be used for the coil embolization of difficult aneurysms. PMID:23472717

  18. Ion beam sputter-etched ventricular catheter for hydrocephalus shunt

    NASA Technical Reports Server (NTRS)

    Banks, B. A. (Inventor)

    1983-01-01

    A cerebrospinal fluid shunt in the form of a ventricular catheter for controlling the condition of hydrocephalus by relieving the excessive cerebrospinal fluid pressure is described. A method for fabrication of the catheter and shunting the cerebral fluid from the cerebral ventricles to other areas of the body is also considered. Shunt flow failure occurs if the ventricle collapse due to improper valve function causing overdrainage. The ventricular catheter comprises a multiplicity of inlet microtubules. Each microtubule has both a large openings at its inlet end and a multiplicity of microscopic openings along its lateral surfaces.

  19. Spiculated Bladder Calculi: The Culprit for Repeated Catheter Failure

    PubMed Central

    Wek, C.; Fox, T. P.; Muir, G. H.

    2013-01-01

    We report on the case of a frustrated 90-year-old gentleman who was seen in the Accident and Emergency department for the third time in four days with failure of his long-term urethral catheter. He reported that the catheter simply “fell out” with the balloon deflated. On each occasion previously, the catheter had been reinserted in A&E and the patient discharged home. These repeated visits to A&E were understandably a source of much frustration for the patient and his family. On the third presentation, plain abdominal radiography demonstrated a large spiculated bladder calculus. PMID:23984173

  20. Frequency of puncture holes in peritoneal dialysis catheters related to the beta cap adapter.

    PubMed

    Ohashi, Yasushi; Kansal, Sheru; Schreiber, Martin

    2012-01-01

    Between November 2009 and September 2011, 12 patients (6 women, 6 men) undergoing continuous peritoneal dialysis (PD) or automated PD developed puncture-like holes in the PD catheter near the interface of the adapter with the superior aspect of the Silastic PD catheter The adapter is used to connect the PD catheter to the PD transfer set. Over the course of 23 months, the 12 patients presented to the PD unit with 19 separate instances of catheter holes, for an event rate of 0.23 holes per patient-year Data including socio-demographic information, PD modality, need for antibiotic treatment, event recurrence, infectious complications, and time from catheter placement were collected from patients whose catheters did and did not develop holes. We observed no differences between patients whose catheters developed holes and those whose catheters did not. The location of the individual holes suggested a relationship between the adapter and the catheter holes. The holes, which led to increased patient morbidity and costs, may be related to structural changes made in 2006 to the adapter.

  1. Radiofrequency catheter ablation of Type 1 atrial flutter using a large-tip electrode catheter and high-power radiofrequency energy generator.

    PubMed

    Feld, Gregory K

    2004-11-01

    Recent studies have demonstrated a high degree of efficacy of 8 mm electrode-tipped or saline-irrigated-tip catheters for ablation of atrial flutter (AFL). These catheters have a theoretical advantage as they produce a large ablation lesion. However, large-tip ablation catheters have a larger surface area and require a higher power radiofrequency (RF) generator with up to 100 W capacity to produce adequate ablation temperatures (50-60 degrees C). The potential advantages of a large-tip ablation catheter and high-power RF generator include the need for fewer energy applications, shorter procedure and fluoroscopy times, and greater efficacy. Therefore, the safety and efficacy of AFL ablation using 8 or 10 mm electrode catheters and a 100-W RF generator was studied using the Boston Scientific, Inc., EPT-1000 XP cardiac ablation system. There were 169 patients, aged 61 +/- 12 years involved. Acute end points were bidirectional isthmus block and no inducible AFL. Following ablation, patients were seen at 1, 3 and 6 months, with event monitoring performed weekly and for any symptoms. Three quality of life surveys were completed during follow-up. Acute success was achieved in 158 patients (93%), with 12 +/- 11 RF energy applications. The efficacy of 8 and 10 mm electrodes did not differ significantly. The number of RF energy applications (10 +/- 8 vs. 14 +/- 8) and ablation time (0.5 +/- 0.4 vs. 0.8 +/- 0.6 h) were less with 10 mm compared with 8 mm electrodes (p < 0.01). Of 158 patients with acute success, 42 were not evaluated at 6 months due to study exclusions. Of the 116 patients evaluated at 6 months, 112 (97%) had no AFL recurrence. Of those without AFL recurrence at 6 months, 95 and 93% were free of symptoms at 12 and 24 months, respectively. Ablation of AFL improved quality of life scores (p < 0.05) and reduced anti-arrhythmic and rate control drug use (p < 0.05). Complications occurred in six out of 169 patients (3.6%) but there were no deaths. It was concluded

  2. Left Atrial Anatomy Relevant to Catheter Ablation

    PubMed Central

    Sánchez-Quintana, Damián; Cabrera, José Angel; Saremi, Farhood

    2014-01-01

    The rapid development of interventional procedures for the treatment of arrhythmias in humans, especially the use of catheter ablation techniques, has renewed interest in cardiac anatomy. Although the substrates of atrial fibrillation (AF), its initiation and maintenance, remain to be fully elucidated, catheter ablation in the left atrium (LA) has become a common therapeutic option for patients with this arrhythmia. Using ablation catheters, various isolation lines and focal targets are created, the majority of which are based on gross anatomical, electroanatomical, and myoarchitectual patterns of the left atrial wall. Our aim was therefore to review the gross morphological and architectural features of the LA and their relations to extracardiac structures. The latter have also become relevant because extracardiac complications of AF ablation can occur, due to injuries to the phrenic and vagal plexus nerves, adjacent coronary arteries, or the esophageal wall causing devastating consequences. PMID:25057427

  3. Chronic swine instrumentation techniques utilizing the GOR-REX peritoneal catheter

    NASA Astrophysics Data System (ADS)

    Gray, C. C.; White, F. C.; Crisman, R. P.; Wisniewski, J.; McKirnan, D.

    1985-05-01

    The GORE-TEX peritoneal catheter interface is an effective skin interface device for many types of instrumentation in the swine. When properly utilized, the interface allows the development of a stable and effective biological seal which will reduce or eliminate sinus tract formation and resultant systemic infection. The interface is suitable for running any wire or catheter (up to about 2.5mm diameter) through the integument of the animal, thus increasing the possibilities for chronic instrumentation while maintaining a healthy animal. The lack of evidence of any growth phenomenon acting to extrude the interface segment, similar to that observed using other synthetic materials, and the superior biological seal which the interface develops, may allow many chronic studies which were previously not feasible. Using special catheter adapter stubs and an intermittent infusion plug, a sterile, sealed catheter system has decreased the possibilities for introducing pathogens while allowing ready access to the blood stream. Detailed descriptions of surgical implantation techniques and catheter set up and maintenance techniques are included.

  4. Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma Yingliang; Housden, R. James; Razavi, Reza

    2013-07-15

    Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors presentmore » a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to

  5. Endometrial lesions caused by catheters used for embryo transfers: a preliminary report.

    PubMed

    Marconi, Guillermo; Vilela, Martín; Belló, José; Diradourián, Marco; Quintana, Ramiro; Sueldo, Carlos

    2003-08-01

    To visualize by microhysteroscopy any possible lesions on the endocervix and endometrium made by the catheters commonly used for embryo transfer (ET). Prospective descriptive study. Tertiary fertility center (IFER). Twenty-three infertile patients underwent a mock transfer before a microhysteroscopy during the postovulatory phase (days 2-5 after ovulation) of the cycle with a Tomcat catheter (n = 5), Frydman's catheter (n = 5), Frydman's set (n = 3), or Wallace's catheter (n = 10). Mock ETs and subsequent mycrohysteroscopies.Visualization, description, and documentation of endocervical and endometrial lesions. The lesions in all 23 patients were described and documented (tunnel-like, groove-like, punch-out, crater-like). The Wallace catheter appears to be less traumatic to the endometrium (but it seems that it is important to take care to not pass the internal os with the outer sheath). The Tomcat catheter and the Frydman's set caused the more significant lesions that were observed. In this preliminary study, for the first time endometrial lesions caused by the ET catheters were directly visualized and documented. Some of these observed lesions appear to be capable of compromising the success of ET.

  6. Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization

    PubMed Central

    Qureshi, Adnan I.; Xiao, WeiGang; Liu, HongLiang

    2015-01-01

    Background The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. Methods A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. Results The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. Conclusions The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations. PMID:26600925

  7. Scale-space for empty catheter segmentation in PCI fluoroscopic images.

    PubMed

    Bacchuwar, Ketan; Cousty, Jean; Vaillant, Régis; Najman, Laurent

    2017-07-01

    In this article, we present a method for empty guiding catheter segmentation in fluoroscopic X-ray images. The guiding catheter, being a commonly visible landmark, its segmentation is an important and a difficult brick for Percutaneous Coronary Intervention (PCI) procedure modeling. In number of clinical situations, the catheter is empty and appears as a low contrasted structure with two parallel and partially disconnected edges. To segment it, we work on the level-set scale-space of image, the min tree, to extract curve blobs. We then propose a novel structural scale-space, a hierarchy built on these curve blobs. The deep connected component, i.e. the cluster of curve blobs on this hierarchy, that maximizes the likelihood to be an empty catheter is retained as final segmentation. We evaluate the performance of the algorithm on a database of 1250 fluoroscopic images from 6 patients. As a result, we obtain very good qualitative and quantitative segmentation performance, with mean precision and recall of 80.48 and 63.04% respectively. We develop a novel structural scale-space to segment a structured object, the empty catheter, in challenging situations where the information content is very sparse in the images. Fully-automatic empty catheter segmentation in X-ray fluoroscopic images is an important and preliminary step in PCI procedure modeling, as it aids in tagging the arrival and removal location of other interventional tools.

  8. Cholorhexidine, octenidine or povidone iodine for catheter related infections: A randomized controlled trial.

    PubMed

    Bilir, Ayten; Yelken, Birgül; Erkan, Ayse

    2013-06-01

    Protection of the catheter site by antimicrobial agents is one of the most important factors in the prevention of infection. Povidone iodine and chlorhexidine gluconate are the most common used agents for dressing. The purpose of this study was to compare the effects of povidone iodine, chlorhexidine gluconate and octenidine hydrochloride in preventing catheter related infections. Patients were randomized to receive; 4% chlorhexidine gluconate, 10% povidone iodine or octenidine hydrochlorodine for cutaneous antisepsis. Cultures were taken at the site surrounding catheter insertion and at the catheter hub after removal to help identify the source of microorganisms. Catheter related sepsis was 10.5% in the povidone iodine and octenidine hydrochlorodine groups. Catheter related colonization was 26.3% in povidone iodine group and 21.5% in octenidine hydrochlorodine group. 4% chlorhexidine or octenidine hydrochlorodine for cutaneous disinfection before insertion of an intravascular device and for post-insertion site care can reduce the catheter related colonization.

  9. Cholorhexidine, octenidine or povidone iodine for catheter related infections: A randomized controlled trial

    PubMed Central

    Bilir, Ayten; Yelken, Birgül; Erkan, Ayse

    2013-01-01

    Background: Protection of the catheter site by antimicrobial agents is one of the most important factors in the prevention of infection. Povidone iodine and chlorhexidine gluconate are the most common used agents for dressing. The purpose of this study was to compare the effects of povidone iodine, chlorhexidine gluconate and octenidine hydrochloride in preventing catheter related infections. Materials and Methods: Patients were randomized to receive; 4% chlorhexidine gluconate, 10% povidone iodine or octenidine hydrochlorodine for cutaneous antisepsis. Cultures were taken at the site surrounding catheter insertion and at the catheter hub after removal to help identify the source of microorganisms. Results: Catheter related sepsis was 10.5% in the povidone iodine and octenidine hydrochlorodine groups. Catheter related colonization was 26.3% in povidone iodine group and 21.5% in octenidine hydrochlorodine group. Conclusion: 4% chlorhexidine or octenidine hydrochlorodine for cutaneous disinfection before insertion of an intravascular device and for post-insertion site care can reduce the catheter related colonization. PMID:24250702

  10. Blocked urinary catheters: solutions are not the only solution.

    PubMed

    Williams, Cath; Tonkin, Sharon

    2003-07-01

    The use of catheter maintenance solutions to manage clients whose catheters block has long been a subject for debate. An understanding of the causes of blockage, and awareness of appropriate management may reduce frequency of blockage and reduce unnecessary interruptions to a closed urinary drainage system.

  11. Fiber photo-catheters for laser treatment of atrial fibrillation

    PubMed Central

    Peshko, Igor; Rubtsov, Vladimir; Vesselov, Leonid; Sigal, Gennady; Laks, Hillel

    2009-01-01

    A fiber photo-catheter has been developed for surgical treatment of atrial fibrillation with laser radiation. Atrial fibrillation (AF) is a heart rhythm abnormality that involves irregular and rapid heartbeats. Recent studies demonstrate the superiority of treating AF disease with optical radiation of the near infrared region. To produce long continuous transmural lesions, solid-state lasers and laser diodes, along with end-emitting fiber catheters, have been used experimentally. The absence of side-emitting flexible catheters with the ability to produce long continuous lesions limits the further development of this technology. In this research, a prototype of an optical catheter, consisting of a flexible 10-cm fiber diffuser has been used to make continuous photocoagulation lesions for effective maze procedure treatments. The system also includes: a flexible optical reflector; a series of openings for rapid self-attachment to the tissue; and an optional closed-loop irrigating chamber with circulating saline to cool the optical diffuser and irrigate the tissue. PMID:19587838

  12. Bi-layer sandwich film for antibacterial catheters

    PubMed Central

    Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly(p-xylylene). This top layer is mainly designed to release a controlled amount of Ag+ ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens’ reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin’s pot and the principle of Le Chatelier. PMID:29046846

  13. Bi-layer sandwich film for antibacterial catheters.

    PubMed

    Franz, Gerhard; Schamberger, Florian; Zare, Hamideh Heidari; Bröskamp, Sara Felicitas; Jocham, Dieter

    2017-01-01

    Background: Approximately one quarter of all nosocomial infections can be attributed to the urinary tract. The infections are supposed to be mainly caused by implantations of urethral catheters and stents. A new catheter design is introduced with the aim to lower the high number of nosocomial urethral infections. In order to avoid limitations to use, the design is first applied to conventional commercially available balloon catheters. Results: The main feature of the design is a sandwich layer on both sides of the catheter wall, which is composed of a fragmented base layer of silver capped by a thin film of poly( p -xylylene). This top layer is mainly designed to release a controlled amount of Ag + ions, which is bactericidal, but not toxic to humans. Simultaneously, the lifetime is prolonged to at least one year. The base layer is electrolessly deposited applying Tollens' reagens, the cap layer is deposited by using chemical vapor deposition. Conclusion: The three main problems of this process, electroless deposition of a fragmented silver film on the surface of an electrically insulating organic polymer, irreproducible evaporation during heating of the precursor, and exponential decrease of the layer thickness along the capillary, have been solved trough the application of a simple electrochemical reaction and two standard principles of physics: Papin's pot and the principle of Le Chatelier.

  14. Catheter ablation in patients with persistent atrial fibrillation

    PubMed Central

    Kirchhof, Paulus; Calkins, Hugh

    2017-01-01

    Catheter ablation is increasingly offered to patients who suffer from symptoms due to atrial fibrillation (AF), based on a growing body of evidence illustrating its efficacy compared with antiarrhythmic drug therapy. Approximately one-third of AF ablation procedures are currently performed in patients with persistent or long-standing persistent AF. Here, we review the available information to guide catheter ablation in these more chronic forms of AF. We identify the following principles: Our clinical ability to discriminate paroxysmal and persistent AF is limited. Pulmonary vein isolation is a reasonable and effective first approach for catheter ablation of persistent AF. Other ablation strategies are being developed and need to be properly evaluated in controlled, multicentre trials. Treatment of concomitant conditions promoting recurrent AF by life style interventions and medical therapy should be a routine adjunct to catheter ablation of persistent AF. Early rhythm control therapy has a biological rationale and trials evaluating its value are underway. There is a clear need to generate more evidence for the best approach to ablation of persistent AF beyond pulmonary vein isolation in the form of adequately powered controlled multi-centre trials. PMID:27389907

  15. Solid-state vs water-perfused catheters to measure colonic high-amplitude propagating contractions.

    PubMed

    Liem, O; Burgers, R E; Connor, F L; Benninga, M A; Reddy, S N; Mousa, H M; Di Lorenzo, C

    2012-04-01

      Solid-state (SS) manometry catheters with portable data loggers offer many potential advantages over traditional water-perfused (WP) systems, such as prolonged recordings in a more physiologic ambulatory setting and the lack of risk for water overload. The use of SS catheters has not been evaluated in comparison with perfused catheters in children. This study aims to compare data provided by SS and WP catheters in children undergoing colonic manometry studies.   A SS catheter and a WP catheter were taped together such that their corresponding sensors were at the same location. Simultaneous recordings were obtained using the SS and WP catheters (both 8 channels, 10 cm apart) in 15 children with severe defecation disorders referred for colonic manometry. Signals were recorded for a minimum of 1 h during fasting, 1 h after ingestion of a meal, and 1 h after the administration of bisacodyl. Solid-state signals from the data logger were analyzed against the perfused signals. All high-amplitude propagated contractions (HAPCs), the most recognizable and interpreted colonic motor event, were evaluated for spatial and temporal features including their durations, amplitudes, and propagation velocities.   A total of 107 HAPCs were detected with SS and 91 with WP catheters. All WP-HAPC were also observed with SS. Linear regression analysis showed that SS catheters tended to give higher readings in the presence of amplitudes <102 mmHg and lower reading with amplitudes >102 mmHg. An opposite trend was found for the duration of contractions. No significant difference was found for HAPC velocity.   SS catheters are more sensitive in recording HAPCs in children with defecation disorders compared with the more traditional WP assembly. There is a difference in measurements of amplitude between the two systems. Solid-state catheters offer potential advantages over WP catheters in children, being portable, safer to use, and may provide data over a more prolonged period.

  16. Risk factors associated with catheter-related upper extremity deep vein thrombosis in patients with peripherally inserted central venous catheters: literature review: part 1.

    PubMed

    Clemence, Bonnie J; Maneval, Rhonda E

    2014-01-01

    This is part 1 of a 2-part series of articles that report on the results of a prospective observational cohort study designed to examine the risk factors associated with symptomatic upper extremity deep vein thrombosis (UEDVT) in patients with peripherally inserted central catheters. This article provides an extensive review and critique of the literature that serves to explicate what is currently known about risk factors associated with catheter-related UEDVT. Risk factors such as anticoagulant use, cancer, infection, hypertension, catheter tip placement, and catheter size were identified most frequently in the literature as being associated with UEDVT development. Other risk factors--such as obesity, smoking history, surgery, and presence of pain or edema--were examined in a limited number of studies and lacked consistent evidence of their impact on UEDVT development. The subsequent study that evolved from the review of the literature investigates the relationship between identified risk factors and UEDVT development.

  17. Catheter-Related Bloodstream Infections in Patients on Emergent Hemodialysis.

    PubMed

    Rojas-Moreno, Christian A; Spiegel, Daniel; Yalamanchili, Venkata; Kuo, Elizabeth; Quinones, Henry; Sreeramoju, Pranavi V; Luby, James P

    2016-03-01

    This study had 2 objectives: (1) to describe the epidemiology of catheter-related bloodstream infections (CRBSI) in patients with end-stage renal disease (ESRD) who have no access to scheduled dialysis and (2) to evaluate whether a positive culture of the heparin-lock solution is associated with subsequent development of bacteremia. Retrospective observational cohort design for objective 1; and prospective cohort design for objective 2. The study was conducted in a 770-bed public academic tertiary hospital in Dallas, Texas. The participants were patients with ESRD undergoing scheduled or emergent hemodialysis. We reviewed the records of 147 patients who received hemodialysis between January 2011 and May 2011 and evaluated the rate of CRBSI in the previous 5 years. For the prospective study, we cultured the catheter heparin-lock solution in 62 consecutive patients between June 2012 and August 2012 and evaluated the incidence of CRBSI at 6 months. Of the 147 patients on emergent hemodialysis, 125 had a tunneled catheter, with a CRBSI rate of 2.61 per 1,000 catheter days. The predominant organisms were Gram-negative rods (GNR). In the prospective study, we found that the dialysis catheter was colonized more frequently in patients on emergent hemodialysis than in those on scheduled hemodialysis. Colonization with GNR or Staphylococcus aureus was associated with subsequent CRBSI at 6 months follow-up. Patients undergoing emergent hemodialysis via tunneled catheter are predisposed to Gram-negative CRBSI. Culturing the heparin-lock solution may predict subsequent episodes of CRBSI if it shows colonization with GNR or Staphylococcus aureus. Prevention approaches in this population need to be studied further.

  18. [Urinary catheters prevalence study in a university hospital].

    PubMed

    Carrouget, J; Legeay, C; Poirier, A; Azzouzi, A-R; Zahar, J-R; Bigot, P

    2017-04-01

    Urinary tract infection is the most common healthcare-association infection, especially because of urinary catheter. We evaluated our practices concerning catheter insertion and management in our institution. We conducted a single-centre descriptive cross-sectional study during 1 week in September 2014 in all adult departments. We noted prevalence, indications, length, management of urinary catheter (UC) and symptomatic catheter-associated urinary tract infections (SCAUTI). Amongst 1046 patients audited, 125 (12%) had UC. The mean age was 72 years (64.8-79.2). UC prevalence was higher in surgical (88%) and medical (87%) intensive care, urology (50%), geriatrics (18%) and long-term care (18%) departments. The average catheterisation length was 7.8 days (3.8-11.8); it was shorter in surgery than in medicine departments (3.6 vs 9.7 days, P<0.001). Catheters were present for more than 4 days in 60% of the cases. Acute urinary retention was the most frequent indication (59%), significantly more in medical than surgical departments (75% vs 26%). Others indications were perioperative (17%), diuresis monitoring (12%), strict immobilization (4%) and unnecessary indications or staff comfort (4%). A SCAUTI was present in 10% of cases, mostly in medicine department (30% vs 8%). The prevalence of our institution is higher than the national prevalence (8.1%), but still below the European average (17.2%). Control of the risk of CAUTI requires compliance with UC appropriate indications, UC management, and prompt removal of unnecessary UC. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Evaluation of two different epidural catheters in clinical practice. narrowing down the incidence of paresthesia!

    PubMed

    Bouman, E A C; Gramke, H F; Wetzel, N; Vanderbroeck, T H T; Bruinsma, R; Theunissen, M; Kerkkamp, H E M; Marcus, M A E

    2007-01-01

    Although epidural anesthesia is considered safe, several complications may occur during puncture and insertion of a catheter. Incidences of paresthesia vary between 0.2 and 56%. A prospective, open, cohort-controlled pilot study was conducted in 188 patients, ASA I-III, age 19-87 years, scheduled for elective surgery and epidural anesthesia. We evaluated a 20 G polyamide (standard) catheter and a 20 G combined polyurethane-polyamide (new) catheter. Spontaneous reactions upon catheter-insertion, paresthesia on questioning, inadvertent dural or intravascular puncture, and reasons for early catheter removal were recorded. The incidence of paresthesia reported spontaneously was 21.3% with the standard catheter and 16.7% with the new catheter. Systematically asking for paresthesia almost doubled the paraesthesia rate. Intravascular cannulation occurred in 5%. No accidental dural punctures occurred. An overall incidence of 13.3% of technical problems led to early catheter removal. The new catheter was at least equivalent to the standard regarding epidural success rate and safety : rate of paresthesia, intravascular and dural cannulation.

  20. [Biodegradable catheters and urinary stents. When?

    PubMed

    Soria, F; Morcillo, E; López de Alda, A; Pastor, T; Sánchez-Margallo, F M

    2016-10-01

    One of the main wishes in the field of urinary catheters and stents is to arm them with biodegradable characteristics because we consider a failure of these devices the need for retrieval, the forgotten catheter syndrome as well as the adverse effects permanent devices cause after fulfilling their aim. The efforts focused in new designs, coatings and biomaterials aim to increase the biocompatibility of theses internal devices. Lately, there have been correct advances to answer the main challenges regarding biodegradable ureteral devices. Thus, modulation of the rate of degradation has been achieved thanks to new biomaterials and the use of copolymers that enable to choose the time of permanence as it is programmed with conventional double J catheters. Biocompatibility has improved with the use of new polymers that adapt better to the urine. Finally, one of the main problems is elimination of degraded fragments and experimentally it has be demonstrated that new designs elicit controlled degradation, from distal to proximal; using stranding and combination of copolymers degradation may be caused by dilution, reducing fragmentation to the last stages of life of the prosthesis. Moreover, it has been demonstrated that biodegradable catheters potentially may cause less urinary tract infection, less encrustation and predictably they will diminish catheter morbidity, since their degradation process reduces adverse effects. Regarding the development of biodegradable urethral stents, it is necessary to find biomaterials that enable maintaining their biomechanical properties in the long term, keeping open the urethral lumen both in patients with BPH and urethral stenosis. Modulation of the time of degradation of the prosthesis has been achieved, but the appearance of urothelial hyperplasia is still a constant in the initial phases after implantation. The development of drug eluting stents, anti-proliferative or anti-inflammatory, as well as biodegradable stents biocoated is a

  1. Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart.

    PubMed

    Kesner, Samuel B; Howe, Robert D

    2011-01-01

    Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system.

  2. Discriminating Tissue Stiffness with a Haptic Catheter: Feeling the Inside of the Beating Heart

    PubMed Central

    Kesner, Samuel B.; Howe, Robert D.

    2011-01-01

    Catheter devices allow physicians to access the inside of the human body easily and painlessly through natural orifices and vessels. Although catheters allow for the delivery of fluids and drugs, the deployment of devices, and the acquisition of the measurements, they do not allow clinicians to assess the physical properties of tissue inside the body due to the tissue motion and transmission limitations of the catheter devices, including compliance, friction, and backlash. The goal of this research is to increase the tactile information available to physicians during catheter procedures by providing haptic feedback during palpation procedures. To accomplish this goal, we have developed the first motion compensated actuated catheter system that enables haptic perception of fast moving tissue structures. The actuated catheter is instrumented with a distal tip force sensor and a force feedback interface that allows users to adjust the position of the catheter while experiencing the forces on the catheter tip. The efficacy of this device and interface is evaluated through a psychophyisical study comparing how accurately users can differentiate various materials attached to a cardiac motion simulator using the haptic device and a conventional manual catheter. The results demonstrate that haptics improves a user's ability to differentiate material properties and decreases the total number of errors by 50% over the manual catheter system. PMID:25285321

  3. Nerve conduction studies are safe in patients with central venous catheters.

    PubMed

    London, Zachary N; Mundwiler, Andrew; Oral, Hakan; Gallagher, Gary W

    2017-08-01

    It is unknown if central venous catheters bypass the skin's electrical resistance and engender a risk of nerve conduction study-induced cardiac arrhythmia. The objective of this study is to determine if nerve conduction studies affect cardiac conduction and rhythm in patients with central venous catheters. Under continuous 12-lead electrocardiogram monitoring, subjects with and without central venous catheters underwent a series of upper extremity nerve conduction studies. A cardiologist reviewed the electrocardiogram tracings for evidence of cardiac conduction abnormality or arrhythmia. Ten control subjects and 10 subjects with central venous catheters underwent the nerve conduction study protocol. No malignant arrhythmias or conduction abnormalities were noted in either group. Nerve conduction studies of the upper extremities, including both proximal stimulation and repetitive stimulation, do not appear to confer increased risk of cardiac conduction abnormality in those patients with central venous catheters who are not critically ill or have a prior history of arrhythmia. Muscle Nerve 56: 321-323, 2017. © 2016 Wiley Periodicals, Inc.

  4. Forceps biopsy and suction catheter for sampling in pulmonary nodules and infiltrates.

    PubMed

    Peschke, Antje; Wiedemann, Bärbel; Höffken, Gert; Koschel, Dirk

    2012-06-01

    Transbronchial lung biopsy with forceps is a standard procedure in bronchoscopic tissue sampling. Suction catheter aspiration is another technique, but it is not widely known and almost no data exist regarding its diagnostic efficiency. 272 patients were included in a prospective and randomised study between February 2007 and October 2009. All were referred for bronchoscopic evaluation of pulmonary nodules/masses or infiltrates. We compared the diagnostic yield of forceps biopsy and suction catheter aspiration for a definite diagnosis and looked at whether such a diagnosis depends on the underlying pulmonary change. All patients underwent bronchoscopy with forceps biopsy and catheter aspiration. A definitive diagnosis was reached in a total of 183 (67.3%) patients, with catheter aspiration in 140 (51.5%) patients and with forceps biopsy in 136 (50.0%) patients. In 90 (33.1%) patients, a definite diagnosis could only be reached with the combination of both techniques. The diagnostic yield of forceps biopsy was better than catheter aspiration in infiltrates (p = 0.027), but was no different in nodules or masses (p = 0.09). Suction catheter aspiration is a useful technique of bronchoscopic tissue sampling. The combination of catheter aspiration and forceps biopsy results in a higher diagnostic yield than either method used alone.

  5. Short-term infection in cuffed versus noncuffed small bore central catheters: a randomized trial.

    PubMed

    Trerotola, Scott O; Patel, Aalpen A; Shlansky-Goldberg, Richard D; Solomon, Jeffrey A; Mondschein, Jeffrey I; Stavropoulos, S William; Soulen, Michael C; Itkin, Maxim; Chittams, Jesse

    2010-02-01

    To determine if a polyester cuff offered benefit in jugular small-bore central catheters (SBCCs). Eighty-four patients were randomly assigned to receive a 5-F single- or 6-F dual-lumen SBCC with (n = 42) or without (n = 42) a polyester cuff. Follow-up was performed at 2 weeks, 1 month, and 3 months or at catheter removal, whichever came first. At scheduled follow-up, catheter function, patient satisfaction, and infection were determined. At catheter removal, tip culture was performed to determine colonization and jugular vein patency was determined with ultrasonography (US). The overall infection rate was 0.4 per 1,000 catheter days. There was one clinical infection (noncuffed catheter). Colonization occurred in two noncuffed catheters and one cuffed catheter. There was one catheter dislodgment in the noncuffed group and none in the cuffed group. Cuffed catheters were no more difficult to insert but took slightly longer to remove (6 minutes +/- 4.7 vs 5 minutes +/- 3, P = .39) and often required local anesthesia for removal, whereas noncuffed catheters did not (41% vs 0%, P = .001). Partial (two cuffed, 0 noncuffed) or complete (two cuffed, one noncuffed) jugular thrombosis was seen on five of 58 completion US studies (8.6%). A polyester cuff on a SBCC confers no significant benefit in short-term colonization rates. Infection in SBCCs is uncommon. Despite their small diameters, SBCCs can result in jugular thrombosis, an important consideration in any patient requiring long-term venous access. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.

  6. Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog.

    PubMed

    Garcia-Pereira, Fernando L; Sanders, Robert; Shih, Andre C; Sonea, Ioana M; Hauptman, Joseph G

    2013-09-01

    To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. Prospective, experiment. Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia. © 2013 Association of Veterinary

  7. Evaluation of hypopharyngeal suction to eliminate aspiration: the Retro-Esophageal Suction (REScue) catheter.

    PubMed

    Belafsky, Peter C; Mehdizadeh, O B; Ledgerwood, L; Kuhn, M

    2015-02-01

    Profound oropharyngeal dysphagia (OPD) is common and costly. Treatment options are limited. The purpose of this investigation was to evaluate the utility of hypopharyngeal suction at the upper esophageal sphincter (UES) to eliminate aspiration. Five different catheters were passed retrograde up the esophagus and positioned at the UES in a cadaver model of profound OPD. Suction was affixed to each catheter. 10 cc of barium was administered into the pyriform sinus, and videofluoroscopy was utilized to evaluate the presence of aspiration. 6 trials were administered per catheter and for a no catheter control. The outcome measures were the incidence of aspiration, the NIH Swallow Safety Scale (NIH-SSS), and UES opening. Control trials with no suction resulted in an aspiration rate of 100 % (6/6 trials). Negative pressure through 16, 18, 24, and 30 Fr catheter resulted in an aspiration rate of 0 % (0/24 trials; p < 0.001), and suction through a 12-Fr catheter resulted in an aspiration rate of 33 % (2/6 trials; p > 0.05). The mean NIH-SSS improved from 7.0 (±0.0) in the control to 0 (±0.0) with hypopharyngeal suction (18 Fr nasogastric catheter; p < 0.001). Mean UES opening improved from 0.0 (±0.0) mm in the control condition to 8.6 (±0.2) mm with a hypopharyngeal catheter (16 Fr Foley catheter; p < 0.001). Negative pressure applied through retro-esophageal suction catheters (>12 Fr) at the level of the UES reduced aspiration by 100 % and significantly increased UES opening in a cadaveric model of profound oropharyngeal dysphagia.

  8. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    PubMed

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  9. Turkish nurses' level of knowledge regarding implantable port catheter care.

    PubMed

    Özden, Dilek; Çalişkan, Nurcan

    2012-06-01

    The aim of this study was to determine the knowledge levels of Turkish nurses regarding implantable port catheter care. A descriptive method was used inside a university hospital that was located in a Turkish metropolis. The data were collected via a questionnaire that was given to a total of 45 nurses who were employed in the internal medicine clinics where the oncology patients were treated. In this study, 42.2% of the nurses received in-service training about the implantable port catheter. It was determined that the mean knowledge point was 15.13 ± 4.78. The difference between the knowledge points of the nurses regarding implantable port catheter care, based on whether or not the nurses had received in-service training, was statistically significant. Moreover, it was determined that the majority of the nurses did not know where the implantable port catheter is placed, its period of use following implantation, the amount of normal saline to be used for washing the catheter, the special port (Huber) needle, the number of the needle, and the exchange time of these needles. In this study, there existed significant differences between the scores of the nurses who received in-service training about the implantable port catheter and the scores of those who did not receive in-service training. The majority of the nurses who participated in the study were willing to receive in-service training regarding this subject. Thus, the organization of in-service training programs and the implementation of care, according to the developed standards and guidelines, are considered as significant for reducing the occurrence of the complications that are related to the use of the implantable port catheter. © 2011 The Authors. Japan Journal of Nursing Science © 2011 Japan Academy of Nursing Science.

  10. Central venous catheter - dressing change

    MedlinePlus

    ... will need: Sterile gloves Cleaning solution A special sponge A special patch, called a Biopatch A clear ... around the catheter. Clean the skin with the sponge and cleaning solution. Air dry after cleaning. Place ...

  11. Balloon-Inflated Catheters for Enteral Feeding: a Word of Caution.

    PubMed

    Dash, Nihar Ranjan; Singh, Anand Narayan; Kilambi, Ragini

    2018-02-01

    Catheters with inflatable balloons such as a Foley catheter may be used for feeding gastrostomy/jejunostomy. The incorrect or improper use of these catheters can have serious consequences. We report 13 cases of feeding jejunostomy with balloon-inflated catheter's malfunction, some referred to our centre and others operated here over a period of 8 years. The most dramatic consequence of such improper use led to rupture of the small intestine due to inadvertent over-inflation (over 100 ml) of the balloon of the catheter during a contrast study. The patient required a laparotomy with resection and anastomosis of the bowel. Three other patients had similar over-inflation of the balloon leading to severe pain and discomfort. In all three patients, timely deflation of the balloon was sufficient to relieve the symptoms. One patient had intussusception with the inflated balloon acting as a lead point. The patient underwent resection of the small bowel with end jejunostomy and distal mucous fistula. All other patients presented with abdominal pain and distension and intestinal obstruction and were managed non-operatively with deflation of balloon either by aspiration, cutting the balloon port or ultrasound-guided puncture of balloon. Healthcare personnel dealing with patients with indwelling catheters must be educated to suspect, detect and manage such problems. The best measure for such unusual complications of otherwise safe devices would be prevention by training and generation of awareness.

  12. Influence of the stopcock on the efficiency of percutaneous drainage catheters: laboratory evaluation.

    PubMed

    D'Agostino, H B; Park, Y; Moyers, J P; vanSonnenberg, E; Sanchez, R B; Goodacre, B W; Kim, Y H; Vieira, M V

    1992-08-01

    The effects of stopcocks on percutaneous fluid drainage were tested in a laboratory model by using a standard stopcock (6-French inner diameter) and a prototype stopcock (9-French inner diameter) connected to 8-, 10-, 12-, 14-, and 16-French catheters. Catheters were immersed in water alone or in viscous fluid with particulate matter, and the system was connected to low wall suction or gravity drainage. The average volume of fluid aspirated in a given period with and without a stopcock was compared for each catheter. The standard stopcock decreased drainage efficiency for these catheters by 13-42%. This decreased drainage efficiency was worse with the larger catheters. Particulate fluid blocked the stopcock connection for all catheters. With the prototype stopcock, drainage of water alone was reduced by 0-9% for the catheters of different sizes. Particulate fluid did not obstruct the prototype stopcock with any size catheter. With gravity drainage, the volume of water aspirated was reduced by 12-42% with the standard stopcock and by 3-6% with the prototype stopcock. These data suggest that stopcock connections greatly influence the efficiency of the percutaneous drainage systems. Stopcocks with larger inner diameters may improve drainage over that achievable with the stopcocks that are currently available.

  13. Intermittent catheterization with hydrophilic catheters as a treatment of chronic neurogenic urinary retention.

    PubMed

    Chartier-Kastler, Emmanuel; Denys, Pierre

    2011-01-01

    Neurogenic bladder can be effectively managed with intermittent catheterization (IC) to improve or restore continence, but there is no consensus on which type of catheter is preferred. Hydrophilic catheters were developed to reduce urethral friction, thereby minimizing trauma and sticking, and making them more acceptable to the patient, and easier and safer to use. The objective of this article was to review the literature on the benefits of hydrophilic catheters in patients with neurogenic bladder. A large body of experimental and observational evidence, including randomized controlled trials, was identified using PubMed. Compared with plastic catheters that have been manually lubricated with gel, hydrophilic catheters reduce urinary tract infection and microhematuria. Hydrophilic catheters are also associated with high levels of patient satisfaction because they are comfortable to use. There is a wealth of evidence, including randomized controlled trials, to support the benefits of hydrophilic catheters in terms of safety and quality of life, especially in men with spinal cord injury. More data are required for spina bifida, multiple sclerosis, and in women. Further research is warranted, especially large-scale and long-term robust comparisons of different types of catheter, and in well-defined and stratified populations. Copyright © 2010 Wiley-Liss, Inc.

  14. Implementing clinical guidelines to prevent catheter-associated urinary tract infections and improve catheter care in nursing homes: Systematic review.

    PubMed

    Gould, Dinah; Gaze, Sarah; Drey, Nicholas; Cooper, Tracey

    2017-05-01

    Catheter-associated urinary tract infection is the most common health care-associated infection, is considered avoidable, and has cost implications for health services. Prevalence is high in nursing homes, but little research has been undertaken to establish whether implementing clinical guidelines can reduce infection rates in long-term care or improve quality of urinary catheter care. Systematic search and critical appraisal of the literature. Three studies evaluated the impact of implementing a complete clinical guideline. Five additional studies evaluated the impact of implementing individual elements of a clinical guideline. Prevention of catheter-associated urinary tract infection in nursing homes has received little clinical or research attention. Studies concerned with whole guideline implementation emerged as methodologically poor using recognized criteria for critically appraising epidemiologic studies concerned with infection prevention. Research evaluating the impact of single elements of clinical guidelines is more robust, and their findings could be implemented to prevent urinary infections in nursing homes. Copyright © 2017. Published by Elsevier Inc.

  15. Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation.

    PubMed

    Cao, Hong; Tungjitkusolmun, Supan; Choy, Young Bin; Tsai, Jang-Zern; Vorperian, Vicken R; Webster, John G

    2002-03-01

    During radio-frequency (RF) cardiac catheter ablation, there is little information to estimate the contact between the catheter tip electrode and endocardium because only the metal electrode shows up under fluoroscopy. We present a method that utilizes the electrical impedance between the catheter electrode and the dispersive electrode to predict the catheter tip electrode insertion depth into the endocardium. Since the resistivity of blood differs from the resistivity of the endocardium, the impedance increases as the catheter tip lodges deeper in the endocardium. In vitro measurements yielded the impedance-depth relations at 1, 10, 100, and 500 kHz. We predict the depth by spline curve interpolation using the obtained calibration curve. This impedance method gives reasonably accurate predicted depth. We also evaluated alternative methods, such as impedance difference and impedance ratio.

  16. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    PubMed

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  17. Onyx embolization using dual-lumen balloon catheter: initial experience and technical note.

    PubMed

    Paramasivam, Srinivasan; Niimi, Yasunari; Fifi, Johanna; Berenstein, Alejandro

    2013-10-01

    Onyx as an embolization agent for the management of vascular malformation is well established. We report our initial experience with dimethyl-sulphoxide (DMSO) compatible double lumen balloon catheters used for Onyx embolization. Between December 2011 and March 2013, we treated 22 patients aged between 1.5 to 70years with two types of DMSO compatible dual-lumen balloon catheters (Scepter C and Ascent) to treat dural arteriovenous fistulas, brain arteriovenous malformation (AVM) with dural feeders, mandibular, facial, lingual, vertebral and paravertebral AVMs. The catheter has good navigability, compliant balloon on inflation formed a "plug" that has more resistance than Onyx plug enhancing better penetration. During injection, the balloon remained stable without spontaneous deflation or rupture and withstood the pressure build-up well. The retrieval of the catheter in most cases took less than a minute (19/28) while in five, it was less than five minutes and in the remaining four, it was longer that includes a trapped catheter on prolonged attempted retrieval resulted in an epidural hematoma, requiring emergent surgical evacuation. The fluoroscopy time is reduced, as we do not form a proximal onyx plug, the injection time is shorter along with easy and instantaneous removal of the catheter after balloon deflation in most cases. Dual-lumen balloon catheter Onyx embolization is a safe and effective technique. Currently, an important tool to circumvent some of the shortcomings associated with Onyx embolization. The catheter has good navigability, the balloon has stability, tolerance, enhances penetrability. It is easy to retrieve the microcatheter. With the experience gained, and with more compliant balloon catheters available, this technique can be applied to cerebral vessels in near future. Copyright © 2013. Published by Elsevier Masson SAS.

  18. [Reducing urinary catheter use in patients hospitalized in internal medicine departments].

    PubMed

    Shimoni, Zvi

    2014-07-01

    Clinical utility exists in certain situations for introducing a urinary catheter, but its use is the major cause of in-hospitaL acquired urinary tract infections. Furthermore, there are other complications of urinary catheterization, including urethral injury, macroscopic hematuria, and the inability to remove the catheter once introduced. Also, the in-hospital use of an indwelling urinary catheter in the elderly patient is associated with prolonged hospitalizations and an increased risk of in-hospital mortality. Although there are clinical criteria for the use of an indwelling urinary catheter, there is considerable variability in the utilization rates between hospitals and departments. For example, the rates of catheterization in general internal medicine departments usually varies between 8% to 20% and increases with the age of the patients. However, it has been shown that up to 50% of catheterizations are unjustified. Therefore, there are efforts to decrease the rate of use of urinary catheters on the one hand, and to limit the number of days with the indwelling catheter in place on the other hand. These efforts have been partially successful. The root of the problem is that the criteria for catheterization are generally vague, leading to variable interpretations. More precise definitions along with continuous monitoring will likely decrease catheterization rates without putting the patient at risk.

  19. Large-deflection statics analysis of active cardiac catheters through co-rotational modelling.

    PubMed

    Peng Qi; Chen Qiu; Mehndiratta, Aadarsh; I-Ming Chen; Haoyong Yu

    2016-08-01

    This paper presents a co-rotational concept for large-deflection formulation of cardiac catheters. Using this approach, the catheter is first discretized with a number of equal length beam elements and nodes, and the rigid body motions of an individual beam element are separated from its deformations. Therefore, it is adequate for modelling arbitrarily large deflections of a catheter with linear elastic analysis at the local element level. A novel design of active cardiac catheter of 9 Fr in diameter at the beginning of the paper is proposed, which is based on the contra-rotating double helix patterns and is improved from the previous prototypes. The modelling section is followed by MATLAB simulations of various deflections when the catheter is exerted different types of loads. This proves the feasibility of the presented modelling approach. To the best knowledge of the authors, it is the first to utilize this methodology for large-deflection static analysis of the catheter, which will enable more accurate control of robot-assisted cardiac catheterization procedures. Future work would include further experimental validations.

  20. Are the measurements of water-filled and air-charged catheters the same in urodynamics?

    PubMed

    Digesu, G Alessandro; Derpapas, Alexandros; Robshaw, Penny; Vijaya, Gopalan; Hendricken, Caroline; Khullar, Vik

    2014-01-01

    The aim of our study was to compare air-charged and water-filled catheters simultaneously in the measurement of the intravesical, abdominal and detrusor pressure during urodynamic investigations. Consecutive women with lower urinary tract symptoms, referred for urodynamics were prospectively studied. Readings of intravesical pressure (p(ves)), abdominal pressure (p(abd)) and detrusor pressure (p(det)), recorded by both the air-charged and water-filled catheters, were displayed simultaneously and compared at the end of filling, on standing, on sitting prior to voiding and at the maximum involuntary detrusor contraction. The signals (pressures) recorded by both types of catheter were compared using the Bland-Altman plot and paired samples t test. Twenty women with a mean age of 49 (range 36-72) were recruited. One patient with normal urodynamics was excluded in view of the poor quality trace. At each of the four comparison points, the air-charged catheters consistently produced higher mean pressures than the water-filled catheters. There were wide variations in the difference between the readings produced by the two types of catheter. Pressures measured using air-charged catheters are not comparable with water-filled catheters and are therefore not interchangeable. Caution must be used when comparing urodynamic parameters using air-charged and water-filled catheters.