Science.gov

Sample records for ablation zone dimensions

  1. Analysis of iodinated contrast delivered during thermal ablation: is material trapped in the ablation zone?

    NASA Astrophysics Data System (ADS)

    Wu, Po-hung; Brace, Chris L.

    2016-08-01

    Intra-procedural contrast-enhanced CT (CECT) has been proposed to evaluate treatment efficacy of thermal ablation. We hypothesized that contrast material delivered concurrently with thermal ablation may become trapped in the ablation zone, and set out to determine whether such an effect would impact ablation visualization. CECT images were acquired during microwave ablation in normal porcine liver with: (A) normal blood perfusion and no iodinated contrast, (B) normal perfusion and iodinated contrast infusion or (C) no blood perfusion and residual iodinated contrast. Changes in CT attenuation were analyzed from before, during and after ablation to evaluate whether contrast was trapped inside of the ablation zone. Visualization was compared between groups using post-ablation contrast-to-noise ratio (CNR). Attenuation gradients were calculated at the ablation boundary and background to quantitate ablation conspicuity. In Group A, attenuation decreased during ablation due to thermal expansion of tissue water and water vaporization. The ablation zone was difficult to visualize (CNR  =  1.57  ±  0.73, boundary gradient  =  0.7  ±  0.4 HU mm‑1), leading to ablation diameter underestimation compared to gross pathology. Group B ablations saw attenuation increase, suggesting that iodine was trapped inside the ablation zone. However, because the normally perfused liver increased even more, Group B ablations were more visible than Group A (CNR  =  2.04  ±  0.84, boundary gradient  =  6.3  ±  1.1 HU mm‑1) and allowed accurate estimation of the ablation zone dimensions compared to gross pathology. Substantial water vaporization led to substantial attenuation changes in Group C, though the ablation zone boundary was not highly visible (boundary gradient  =  3.9  ±  1.1 HU mm‑1). Our results demonstrate that despite iodinated contrast being trapped in the ablation zone, ablation visibility

  2. Analysis of iodinated contrast delivered during thermal ablation: is material trapped in the ablation zone?

    NASA Astrophysics Data System (ADS)

    Wu, Po-hung; Brace, Chris L.

    2016-08-01

    Intra-procedural contrast-enhanced CT (CECT) has been proposed to evaluate treatment efficacy of thermal ablation. We hypothesized that contrast material delivered concurrently with thermal ablation may become trapped in the ablation zone, and set out to determine whether such an effect would impact ablation visualization. CECT images were acquired during microwave ablation in normal porcine liver with: (A) normal blood perfusion and no iodinated contrast, (B) normal perfusion and iodinated contrast infusion or (C) no blood perfusion and residual iodinated contrast. Changes in CT attenuation were analyzed from before, during and after ablation to evaluate whether contrast was trapped inside of the ablation zone. Visualization was compared between groups using post-ablation contrast-to-noise ratio (CNR). Attenuation gradients were calculated at the ablation boundary and background to quantitate ablation conspicuity. In Group A, attenuation decreased during ablation due to thermal expansion of tissue water and water vaporization. The ablation zone was difficult to visualize (CNR  =  1.57  ±  0.73, boundary gradient  =  0.7  ±  0.4 HU mm-1), leading to ablation diameter underestimation compared to gross pathology. Group B ablations saw attenuation increase, suggesting that iodine was trapped inside the ablation zone. However, because the normally perfused liver increased even more, Group B ablations were more visible than Group A (CNR  =  2.04  ±  0.84, boundary gradient  =  6.3  ±  1.1 HU mm-1) and allowed accurate estimation of the ablation zone dimensions compared to gross pathology. Substantial water vaporization led to substantial attenuation changes in Group C, though the ablation zone boundary was not highly visible (boundary gradient  =  3.9  ±  1.1 HU mm-1). Our results demonstrate that despite iodinated contrast being trapped in the ablation zone, ablation visibility was

  3. Interactive Volumetry Of Liver Ablation Zones

    PubMed Central

    Egger, Jan; Busse, Harald; Brandmaier, Philipp; Seider, Daniel; Gawlitza, Matthias; Strocka, Steffen; Voglreiter, Philip; Dokter, Mark; Hofmann, Michael; Kainz, Bernhard; Hann, Alexander; Chen, Xiaojun; Alhonnoro, Tuomas; Pollari, Mika; Schmalstieg, Dieter; Moche, Michael

    2015-01-01

    Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm’s results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow. PMID:26482818

  4. Interactive Volumetry Of Liver Ablation Zones

    NASA Astrophysics Data System (ADS)

    Egger, Jan; Busse, Harald; Brandmaier, Philipp; Seider, Daniel; Gawlitza, Matthias; Strocka, Steffen; Voglreiter, Philip; Dokter, Mark; Hofmann, Michael; Kainz, Bernhard; Hann, Alexander; Chen, Xiaojun; Alhonnoro, Tuomas; Pollari, Mika; Schmalstieg, Dieter; Moche, Michael

    2015-10-01

    Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm’s results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow.

  5. Microwave ablation at 10.0 GHz achieves comparable ablation zones to 1.9 GHz in ex vivo bovine liver.

    PubMed

    Luyen, Hung; Gao, Fuqiang; Hagness, Susan C; Behdad, Nader

    2014-06-01

    We demonstrate the feasibility of using high-frequency microwaves for tissue ablation by comparing the performance of a 10 GHz microwave ablation system with that of a 1.9 GHz system. Two sets of floating sleeve dipole antennas operating at these frequencies were designed and fabricated for use in ex vivo experiments with bovine livers. Combined electromagnetic and transient thermal simulations were conducted to analyze the performance of these antennas. Subsequently, a total of 16 ablation experiments (eight at 1.9 GHz and eight at 10.0 GHz) were conducted at a power level of 42 W for either 5 or 10 min. In all cases, the 1.9 and 10 GHz experiments resulted in comparable ablation zone dimensions. Temperature monitoring probes revealed faster heating rates in the immediate vicinity of the 10.0 GHz antenna compared to the 1.9 GHz antenna, along with a slightly delayed onset of heating farther from the 10 GHz antenna, suggesting that heat conduction plays a greater role at higher microwave frequencies in achieving a comparably sized ablation zone. The results obtained from these experiments agree very well with the combined electromagnetic/thermal simulation results. These simulations and experiments show that using lower frequency microwaves does not offer any significant advantages, in terms of the achievable ablation zones, over using higher frequency microwaves. Indeed, it is demonstrated that high-frequency microwave antennas may be used to create reasonably large ablation zones. Higher frequencies offer the advantage of smaller antenna size, which is expected to lead to less invasive interstitial devices and may possibly lead to the development of more compact multielement arrays with heating properties not available from single-element antennas.

  6. Creation of short microwave ablation zones: In Vivo Characterization of single and paired Modified Triaxial Antennas Laboratory Investigation

    PubMed Central

    Lubner, Meghan G.; Ziemlewicz, Tim J; Hinshaw, J. Louis; Lee, Fred T.; Sampson, Lisa J.; Brace, Chris L.

    2014-01-01

    Purpose To characterize modified triaxial microwave antennas configured to produce short ablation zones. Materials and Methods 50 single- and 27 paired-antenna hepatic ablations were performed in domestic swine (n=11) with 17-gauge, gas-cooled modified triaxial antennas powered at 65W from a 2.45 GHz generator. Single-antenna ablations were performed at 2 (n=16), 5 (n=21), and 10 (n=13) minutes. Paired-antenna ablations were performed at 1-cm and 2-cm spacing for 5 (n=7, n=8) and 10 minutes (n=7, n=5). Mean transverse width, length and aspect ratio of sectioned ablation zones were measured and compared. Results For single antennas, mean ablation zone length was 2.9±0.45, 3.5±0.55 and 4.2±0.40 cm at 2, 5, and 10 minutes respectively. Mean width was 1.8±0.3, 2.0±0.32, 2.5±0.25 cm at 2, 5, and 10 minutes. For paired antennas, mean length at 5 min 1 and 2 cm and 10 min 1 and 2 cm spacing was 4.2±0.9, 4.4±0.9, 4.8±0.5 and 4.3±0.9 cm respectively. Mean width was 3.1±1.0, 4.0±0.8 and 3.8±0.4, 4.2±0.6 cm respectively. Paired-antenna ablations were more spherical (aspect ratios 0.72-0.79 for 5-10 min) than single-antenna ablations (0.57-0.59). For paired-antenna ablations, 1 cm spacing appeared optimal, with improved circularity and decreased clefting compared to 2 cm spacing (circ 1 cm 0.85, 2 cm 0.78). Conclusion Modified triaxial antennas can generate relatively short, spherical ablation zones. Paired-antenna ablations were rounder and larger in transverse dimension compared to single antenna ablations, with 1 cm spacing optimal for confluence of the ablation zone. PMID:25156644

  7. Microfabrication of Fresnel zone plates by laser induced solid ablation

    NASA Astrophysics Data System (ADS)

    Rodrigues, Vanessa R. M.; Thomas, John; Santhosh, Chidangil; Ramachandran, Hema; Mathur, Deepak

    2016-07-01

    A novel and simple single-step method of inscribing optical elements on metal-coated transparent substrates is demonstrated. Laser induced solid ablation (LISA) demands very low laser energies (nJ), as can be amply provided by a femtosecond laser oscillator. Here, LISA is used to write Fresnel zone plates on indium and tungsten coated glass. With up to 100 zones, remarkable agreement is obtained between measured and expected values of the focal length. LISA has enabled attainment of focal spot sizes that are 38% smaller than what would be obtained using conventional lenses of the same numerical aperture. The simplicity with which a high degree of automation can readily be achieved using LISA makes this cost-effective method amenable to a wide variety of applications related to microfabrication of optical elements.

  8. Bimodal albedo distributions in the ablation zone of the southwestern Greenland Ice Sheet

    NASA Astrophysics Data System (ADS)

    Moustafa, S. E.; Rennermalm, A. K.; Smith, L. C.; Miller, M. A.; Mioduszewski, J. R.

    2014-09-01

    Surface albedo is a key variable controlling solar radiation absorbed at the Greenland Ice Sheet (GrIS) surface, and thus, meltwater production. Recent decline in surface albedo over the GrIS has been linked to enhanced snow grain metamorphic rates and amplified ice-albedo feedback from atmospheric warming. However, the importance of distinct surface types on ablation zone albedo and meltwater production is still relatively unknown, and excluded in surface mass balance models. In this study, we analyze albedo and ablation rates using in situ and remotely-sensed data. Observations include: (1) a new high-quality in situ spectral albedo dataset collected with an Analytical Spectral Devices (ASD) spectroradiometer measuring at 325-1075 nm, along a 1.25 km transect during three days in June 2013; (2) broadband albedo at two automatic weather stations; and (3) daily MODerate Resolution Imaging Spectroradiometer (MODIS) albedo (MOD10A1) between 31 May and 30 August. We find that seasonal ablation zone albedos have a bimodal distribution, with two alternate states. This suggests that an abrupt switch from high to low albedo can be triggered by a modest melt event, resulting in amplified surface ablation rates. Our results show that such a shift corresponds to an observed melt rate percent difference increase of 51.6% during peak melt season (between 10-14 and 20-24 July 2013). Furthermore, our findings demonstrate that seasonal changes in GrIS ablation zone albedo are not exclusively a function of a darkening surface from ice crystal growth, but rather are controlled by changes in the fractional coverage of snow, bare ice, and impurity-rich surface types. As the climate continues to warm, regional climate models should consider the seasonal evolution of ice surface types in Greenland's ablation zone to improve projections of mass loss contributions to sea level rise.

  9. Bimodal Albedo Distributions in the Ablation Zone of the Southwestern Greenland Ice Sheet

    NASA Astrophysics Data System (ADS)

    Moustafa, S.; Rennermalm, A. K.; Smith, L. C.; Miller, M. A.; Mioduszewski, J.; Koenig, L.

    2014-12-01

    Surface albedo is a key variable controlling solar radiation absorbed at the Greenland Ice Sheet (GrIS) surface, and thus meltwater production. Recent decline in surface albedo over the GrIS has been linked to enhanced snow grain metamorphic rates and amplified ice-albedo feedback from atmospheric warming. However, the importance of distinct surface types on ablation zone albedo and meltwater production is still relatively unknown, and excluded in surface mass balance models. In this study, we analyze albedo and ablation rates (m d-1) using in situ and remotely-sensed data. Observations include: 1) a new high-quality in situ spectral albedo dataset collected with an Analytical Spectral Devices (ASD) spectroradiometer measuring at 325-1075 nm, along a 1.25 km transect during three days in June 2013; 2) broadband albedo at two automatic weather stations; and 3) daily MODerate Resolution Imaging Spectroradiometer (MODIS) albedo (MOD10A1) between 31 May and 30 August. We find that seasonal ablation zone albedos have a bimodal distribution, with two alternate states. This suggests that an abrupt switch from high to low albedo can be triggered by a modest melt event, resulting in amplified ablation rates. Our results show that such a shift corresponds to an observed melt rate percent difference increase of 51.6% during peak melt season (between 10-14 July and 20-24 July, 2013). Furthermore, our findings demonstrate that seasonal changes in GrIS ablation zone albedo are not exclusively a function of a darkening surface from ice crystal growth, but rather are controlled by changes in the fractional coverage of snow, bare ice, and impurity-rich surface types. As the climate continues to warm, regional climate models should consider the seasonal evolution of ice surface types in Greenland's ablation zone to improve projections of mass loss contributions to sea level rise.

  10. Initial Steps Toward a Hydrologic "Watershed" Model for the Ablation Zone of the Greenland Ice Sheet

    NASA Astrophysics Data System (ADS)

    Cooper, M. G.; Smith, L. C.; Rennermalm, A. K.; Pitcher, L. H.; Overstreet, B. T.; Chu, V. W.; Ryan, J.; Yang, K.

    2015-12-01

    Surface meltwater production on the Greenland Ice Sheet (GrIS) is a well-documented phenomenon but we lack understanding of the physical mechanisms that control the production, transport, and fate of the meltwater. To address this, we present initial steps toward the development of a novel hydrologic model for supraglacial streamflow on the GrIS. Ice ablation and surface meteorology were measured during a 6-day field campaign in a 112 km2 ablation zone of southwest Greenland. We modeled ablation using SnowModel, an energy balance snow- and ice-ablation model. The required model inputs included standard surface meteorology and a digital elevation model (DEM), and the model outputs include all components of the energy balance and surface meltwater production for each grid cell in the ice-sheet watershed. Our next steps toward developing a complete hydrologic model for supraglacial streamflow in the ablation zone of the GrIS include the application of the meltwater-routing model HydroFlow to compare with in-situ measurements of supraglacial river discharge.

  11. Radiofrequency Ablation of Lung Tumors: Imaging Features of the Postablation Zone

    PubMed Central

    Eradat, Jilbert; Gutierrez, Antonio J.; Lee, Christopher; Fishbein, Michael C.; Suh, Robert D.

    2012-01-01

    Radiofrequency ablation (RFA) is used to treat pulmonary malignancies. Although preliminary results are suggestive of a survival benefit, local progression rates are appreciable. Because a patient can undergo repeat treatment if recurrence is detected early, reliable post-RFA imaging follow-up is critical. The purpose of this article is to describe (a) an algorithm for post-RFA imaging surveillance; (b) the computed tomographic (CT) appearance, size, enhancement, and positron emission tomographic (PET) metabolic activity of the ablation zone; and (c) CT, PET, and dual-modality imaging with PET and CT (PET/CT) features suggestive of partial ablation or tumor recurrence and progression. CT is routinely used for post-RFA follow-up. PET and PET/CT have emerged as auxiliary follow-up techniques. CT with nodule densitometry may be used to supplement standard CT. Post-RFA follow-up was divided into three phases: early (immediately after to 1 week after RFA), intermediate (>1 week to 2 months), and late (>2 months). CT and PET imaging features suggestive of residual or recurrent disease include (a) increasing contrast material uptake in the ablation zone (>180 seconds on dynamic images), nodular enhancement measuring more than 10 mm, any central enhancement greater than 15 HU, and enhancement greater than baseline anytime after ablation; (b) growth of the RFA zone after 3 months (compared with baseline) and definitely after 6 months, peripheral nodular growth and change from ground-glass opacity to solid opacity, regional or distant lymph node enlargement, and new intrathoracic or extrathoracic disease; and (c) increased metabolic activity beyond 2 months, residual activity centrally or at the ablated tumor, and development of nodular activity. © RSNA, 2012 PMID:22786987

  12. The Influence of the Aspheric Profiles for Transition Zone on Optical Performance of Human Eye After Conventional Ablation

    NASA Astrophysics Data System (ADS)

    Fang, L.

    2014-12-01

    The analysis in the impact of transition zone on the optical performance of human eye after laser refractive surgery is important for improving visual correction technology. By designing the ablation profiles of aspheric transition zone and creating the ablation profile for conventional refractive surgery in optical zone, the influence of aspheric transition zone on residual aberrations was studied. The results indicated that the ablation profiles of transition zone had a significant influence on the residual wavefront aberrations. For a hyperopia correction, the profile #9 shows a larger induced coma and spherical aberration when the translation of the centre of pupil remains constant. However, for a myopia astigmatism correction, the induced coma and spherical aberration in profile #1 shows relatively larger RMS values than those in other profiles. Therefore, the residual higher order aberrations may be decreased by optimizing ablation profiles of transition zone, but they cannot be eliminated. In order to achieve the best visual performance, the design of ablation pattern of transition zone played a crucial role.

  13. Sustained Growth of the Ex Vivo Ablation Zones' Critical Short Axis Using Gas-cooled Radiofrequency Applicators

    SciTech Connect

    Rempp, Hansjoerg; Scharpf, Marcus; Voigtlaender, Matthias; Schraml, Christina; Schmidt, Diethard; Fend, Falko; Claussen, Claus D.; Enderle, Markus D.; Pereira, Philippe L.; Clasen, Stephan

    2011-02-15

    Purpose: To evaluate the ablation zones created with a gas-cooled bipolar radiofrequency applicator performed on ex vivo bovine liver tissue. Materials and Methods: A total of 320 ablations with an internally gas-cooled bipolar radiofrequency applicator were performed on fresh ex vivo bovine liver tissue, varying the ablation time (5, 10, 15, and 20 min), power (20, 30, 40, and 50 W), and gas pressure of the CO{sub 2} used for cooling (585, 600, 615, 630, 645 psi), leading to a total of 80 different parameter combinations. Size and shape of the white coagulation zone were assessed. Results: The largest complete ablation zone was achieved after 20 min of implementing 50 W and 645 psi, resulting in a short axis of mean 46 {+-} 1 mm and a long axis of 56 {+-} 2 mm (mean {+-} standard deviation). Short-axis diameters increased between 5 and 20 min of ablation time at 585 psi (increase of the short axis was 45% at 30 W, 29% at 40 W, and 39% at 50 W). This increase was larger at 645 psi (113% at 30 W, 67% at 40 W, and 70% at 50 W). Macroscopic assessment and NADH (nicotinamide adenine dinucleotide) staining revealed incompletely ablated tissue along the needle track in 18 parameter combinations including low-power settings (20 and 30 W) and different cooling levels and ablation times. Conclusion: Gas-cooled radiofrequency applicators increase the short-axis diameter of coagulation in an ex vivo setting if appropriate parameters are selected.

  14. Effects of dust and black carbon on albedo of the Greenland ablation zone

    NASA Astrophysics Data System (ADS)

    Boggild, C. E.; Warren, S. G.; Brandt, R. E.; Brown, K. J.

    2006-12-01

    Recent thinning of the perimeter of the Greenland ice sheet has prompted several studies that are focused on identifying possible mechanisms. Surface melting in the ablation zone is known to be highly sensitive to changes in the surface albedo. However, explanations for the variable albedo of the ablation zone in Greenland have not yet been established because ground validation is often difficult due to the inaccessibility of much of the marginal zone. The emergence and melting of old ice in the ablation zone creates a surface layer of dust that was originally deposited with snowfall high on the ice sheet. This debris cover is augmented by locally-derived windblown sediment. Subsequently, the surface dust particles often aggregate together to form millimeter to centimeter scale clumps that melt into the ice, creating cryoconite holes. The debris in the cryoconite holes becomes hidden from sunlight, thus raising the area-averaged albedo. These processes were examined on the readily accessible ice sheet margin of northeast Greenland in Kronprins Christians Land (80 N, 24 W). To assess the effects of dust and black carbon deposition on ice albedo, spectral albedo measurements across the solar spectrum at ultraviolet, visible and near-infrared wavelengths were taken on snow, slush, ice hummocks, debris-covered ice and cryoconite-studded ice. In addition, albedo measurements were likewise taken on the debris in the cryoconite holes. Areal distribution of the aforementioned surface types was estimated as a function of distance from the ice edge (330 m elevation). Ablation rates were measured on a 5-km transect from the ice margin that spanned both Pleistocene and Holocene ice, eventually terminating in the slush zone (550 m). Impurity concentrations (per unit area of surface and per unit volume for snow and subsurface ice) were measured. Snow was also collected for analysis of impurities at distances of 40 and 90 km from the margin, at elevations of 950 and 1440 m

  15. Accidental Inclusions Following Blast Injury in Esthetical Zones: Ablation by a Hydrosurgery System

    PubMed Central

    Siemers, Frank; Mauss, Karl L.; Liodaki, Eirini; Ottomann, Christian; Bergmann, Philipp A.; Mailänder, Peter

    2012-01-01

    In case of blast injuries, traumatic tattoos can result from accidental inclusions of intradermal pigmented particles. To avoid these tattoos, especially in esthetical areas like the head and neck region and the hands, the primary goal in our treatment is to remove all particles and foreign bodies. Superficial foreign bodies can easily be removed by brushes or dermabrasion. Deeper lesions are a challenge for plastic surgeons, because they are not so easily removed. Ablation by a water jet surgical tool, the Versajet-system (Smith & Nephew Inc, Andover, MA), enables the removal of nearly all particles and foreign bodies, which sustained a blast injury of the face or the hands. Aim of this paper is to describe the method of using this hydrosurgery system in blast injuries in esthetical zones and its advantages by presenting cases of two patients of us. PMID:22848777

  16. Measurements of the conduction-zone length and mass ablation rate in cryogenic direct-drive implosions on OMEGA

    SciTech Connect

    Michel, D. T.; Davis, A. K.; Goncharov, V. N.; Sangster, T. C.; Hu, S. X.; Igumenshchev, I. V.; Meyerhofer, D. D.; Seka, W.; Froula, D. H.

    2015-04-14

    Measurements of the conduction-zone length (110 ± 20 μm at t = 2.8 ns), the averaged mass ablation rate of the deuterated plastic (7.95 ± 0.3 μg/ns), shell trajectory, and laser absorption are made in direct-drive cryogenic implosions and are used to quantify the electron thermal transport through the conduction zone. Hydrodynamic simulations that use nonlocal thermal transport and cross-beam energy transfer models reproduce these experimental observables. Hydrodynamic simulations that use a time-dependent flux-limited model reproduce the measured shell trajectory and the laser absorption but underestimate the mass ablation rate by ~10% and the length of the conduction zone by nearly a factor of 2.

  17. Measurements of the Conduction-Zone Length and Mass Ablation Rate in Cryogenic Direct-Drive Implosions on OMEGA

    NASA Astrophysics Data System (ADS)

    Michel, D. T.; Davis, A. K.; Goncharov, V. N.; Sangster, T. C.; Hu, S. X.; Igumenshchev, I. V.; Meyerhofer, D. D.; Seka, W.; Froula, D. H.

    2015-04-01

    Measurements of the conduction-zone length (110 ±20 μ m at t =2.8 ns ), the averaged mass ablation rate of the deuterated plastic (7.95 ±0.3 μ g /ns ), shell trajectory, and laser absorption are made in direct-drive cryogenic implosions and are used to quantify the electron thermal transport through the conduction zone. Hydrodynamic simulations that use nonlocal thermal transport and cross-beam energy transfer models reproduce these experimental observables. Hydrodynamic simulations that use a time-dependent flux-limited model reproduce the measured shell trajectory and the laser absorption but underestimate the mass ablation rate by ˜10 % and the length of the conduction zone by nearly a factor of 2.

  18. Endometrial ablation

    MedlinePlus

    Hysteroscopy-endometrial ablation; Laser thermal ablation; Endometrial ablation-radiofrequency; Endometrial ablation-thermal balloon ablation; Rollerball ablation; Hydrothermal ablation; Novasure ablation

  19. Zone Specific Fractal Dimension of Retinal Images as Predictor of Stroke Incidence

    PubMed Central

    Kumar, Dinesh Kant; Hao, Hao; Unnikrishnan, Premith; Kawasaki, Ryo; Mitchell, Paul

    2014-01-01

    Fractal dimensions (FDs) are frequently used for summarizing the complexity of retinal vascular. However, previous techniques on this topic were not zone specific. A new methodology to measure FD of a specific zone in retinal images has been developed and tested as a marker for stroke prediction. Higuchi's fractal dimension was measured in circumferential direction (FDC) with respect to optic disk (OD), in three concentric regions between OD boundary and 1.5 OD diameter from its margin. The significance of its association with future episode of stroke event was tested using the Blue Mountain Eye Study (BMES) database and compared against spectrum fractal dimension (SFD) and box-counting (BC) dimension. Kruskal-Wallis analysis revealed FDC as a better predictor of stroke (H = 5.80, P = 0.016, α = 0.05) compared with SFD (H = 0.51, P = 0.475, α = 0.05) and BC (H = 0.41, P = 0.520, α = 0.05) with overall lower median value for the cases compared to the control group. This work has shown that there is a significant association between zone specific FDC of eye fundus images with future episode of stroke while this difference is not significant when other FD methods are employed. PMID:25485298

  20. Caterpillar-like ice motion in the ablation zone of the Greenland ice sheet

    NASA Astrophysics Data System (ADS)

    Ryser, C.; Lüthi, M. P.; Andrews, L. C.; Catania, G. A.; Funk, M.; Hawley, R.; Hoffman, M.; Neumann, T. A.

    2014-10-01

    Current understanding of ice dynamics predicts that increasing availability and variability of meltwater will have an impact on basal motion and therefore on the evolution and future behavior of the Greenland ice sheet. We present measurements of ice deformation, subglacial water pressure, and surface velocity that show periodic and episodic variations on several time scales (seasonal, multiday, and diurnal). These variations, observed with GPS and sensors at different depths throughout the ice column, are not synchronous but show delayed responses of ice deformation with increasing depth and basal water pressure in antiphase with surface velocity. With the help of a Full-Stokes ice flow model, these observations are explained as ice motion in a caterpillar-like fashion. Caused by patches of different basal slipperiness, horizontal stress transfer through the stiff central part of the ice body leads to spatially varying surface velocities and ice deformation patterns. Variation of this basal slipperiness induces characteristic patterns of ice deformation variability that explain the observed behavior. Ice flow in the ablation zone of the Greenland ice sheet is therefore controlled by activation of basal patches by varying slipperiness in the course of a melt season, leading to caterpillar-like ice motion superposed on the classical shear deformation.

  1. Helicopter-based Photography for use in SfM over the West Greenland Ablation Zone

    NASA Astrophysics Data System (ADS)

    Mote, T. L.; Tedesco, M.; Astuti, I.; Cotten, D.; Jordan, T.; Rennermalm, A. K.

    2015-12-01

    Results of low-elevation high-resolution aerial photography from a helicopter are reported for a supraglacial watershed in West Greenland. Data were collected at the end of July 2015 over a supraglacial watershed terminating in the Kangerlussuaq region of Greenland and following the Utrecht University K-Transect of meteorological stations. The aerial photography reported here were complementary observations used to support hyperspectral measurements of albedo, discussed in the Greenland Ice sheet hydrology session of this AGU Fall meeting. A compact digital camera was installed inside a pod mounted on the side of the helicopter together with gyroscopes and accelerometers that were used to estimate the relative orientation. Continuous video was collected on 19 and 21 July flights, and frames extracted from the videos are used to create a series of aerial photos. Individual geo-located aerial photos were also taken on a 24 July flight. We demonstrate that by maintaining a constant flight elevation and a near constant ground speed, a helicopter with a mounted camera can produce 3-D structure of the ablation zone of the ice sheet at unprecedented spatial resolution of the order of 5 - 10 cm. By setting the intervalometer on the camera to 2 seconds, the images obtained provide sufficient overlap (>60%) for digital image alignment, even at a flight elevation of ~170m. As a result, very accurate point matching between photographs can be achieved and an extremely dense RGB encoded point cloud can be extracted. Overlapping images provide a series of stereopairs that can be used to create point cloud data consisting of 3 position and 3 color variables, X, Y, Z, R, G, and B. This point cloud is then used to create orthophotos or large scale digital elevation models, thus accurately displaying ice structure. The geo-referenced images provide a ground spatial resolution of approximately 6 cm, permitting analysis of detailed features, such as cryoconite holes, evolving small

  2. Evaluation of the energy transfer in the char zone during ablation. Part 2: In-depth response of ablative composites, volume 1. Ph.D. Thesis, 1975. Final Report

    NASA Technical Reports Server (NTRS)

    Pike, R. W.; Delvalle, E. G.

    1974-01-01

    The decomposition of ablative composites is described along with the transport phenomena of pyrolysis gases which result from the decomposition of these plastics as they flow through the porous char of char-forming ablators. The pyrolysis products are those formed by the thermal degradation of nylon-phenolic resin and silicone elastomer composites. Emphasis is placed on the nature and extent of chemical reactions of the pyrolysis products and the char, along with the energy absorbed by the combined pyrolysis and char zone. Chemical reactions with thermodynamically consistent kinetic data are determined in order to develop a realistic analysis for predicting the thermal performance of ablative heat shields.

  3. Subpixel variability of MODIS albedo retrievals and its importance for ice sheet surface melting in southwestern Greenland's ablation zone

    NASA Astrophysics Data System (ADS)

    Moustafa, S.; Rennermalm, A. K.; Roman, M. O.; Koenig, L.; Smith, L. C.; Schaaf, C.; Wang, Z.; Mioduszewski, J.

    2013-12-01

    On the Greenland ice sheet, albedo declined across 70% of its surface since 2000, with the greatest reduction in the lower 600 m of the southwestern ablation zone. Because albedo plays a prominent role in the ice sheet surface energy balance, its decline has resulted in near doubling of meltwater production. To characterize ice sheet albedo, Moderate Imaging Spectrometer (MODIS) surface albedo products are typically used. However, it is unclear how the spatial variability of albedo within a MODIS pixel influences surface melting and whether it can be considered a linear function of albedo. In this study, high spatiotemporal resolution measurements of spectral albedo and ice sheet surface ablation were collected along a ~ 1.3 km transect during June 2013 within the Akuliarusiarsuup Kuua (AK) River watershed in southwest Greenland. Spectral measurements were made at 325-1075 nm using a Analytical Spectral Devices (ASD) spectroradiometer, fitted with a Remote Cosine Receptor (RCR). In situ albedo measurements are compared with the daily MODIS albedo product (MCD43A) to analyze how space, time, surface heterogeneity, atmospheric conditions, and solar zenith angle geometry govern albedo at different scales. Finally, analysis of sub-pixel albedo and ablation reveal its importance on meltwater production in the lower parts of the ice sheet margin.

  4. The Annual Glaciohydrology Cycle in the Ablation Zone of the Greenland Ice Sheet: Part 1. Hydrology Model

    NASA Technical Reports Server (NTRS)

    Colgan, William; Rajaram, Harihar; Anderson, Robert; Steffen. Konrad; Phillips, Thomas; Zwally, H. Jay; Abdalati, Waleed

    2012-01-01

    We apply a novel one-dimensional glacier hydrology model that calculates hydraulic head to the tidewater-terminating Sermeq Avannarleq flowline of the Greenland ice sheet. Within a plausible parameter space, the model achieves a quasi-steady-state annual cycle in which hydraulic head oscillates close to flotation throughout the ablation zone. Flotation is briefly achieved during the summer melt season along a approx.17 km stretch of the approx.50 km of flowline within the ablation zone. Beneath the majority of the flowline, subglacial conduit storage closes (i.e. obtains minimum radius) during the winter and opens (i.e. obtains maximum radius) during the summer. Along certain stretches of the flowline, the model predicts that subglacial conduit storage remains open throughout the year. A calculated mean glacier water residence time of approx.2.2 years implies that significant amounts of water are stored in the glacier throughout the year. We interpret this residence time as being indicative of the timescale over which the glacier hydrologic system is capable of adjusting to external surface meltwater forcings. Based on in situ ice velocity observations, we suggest that the summer speed-up event generally corresponds to conditions of increasing hydraulic head during inefficient subglacial drainage. Conversely, the slowdown during fall generally corresponds to conditions of decreasing hydraulic head during efficient subglacial drainage.

  5. Radiofrequency Ablation of Liver Metastases-Software-Assisted Evaluation of the Ablation Zone in MDCT: Tumor-Free Follow-Up Versus Local Recurrent Disease

    SciTech Connect

    Keil, Sebastian Bruners, Philipp; Schiffl, Katharina; Sedlmair, Martin; Muehlenbruch, Georg; Guenther, Rolf W.; Das, Marco; Mahnken, Andreas H.

    2010-04-15

    The purpose of this study was to investigate differences in change of size and CT value between local recurrences and tumor-free areas after CT-guided radiofrequency ablation (RFA) of hepatic metastases during follow-up by means of dedicated software for automatic evaluation of hepatic lesions. Thirty-two patients with 54 liver metastases from breast or colorectal cancer underwent triphasic contrast-enhanced multidetector-row computed tomography (MDCT) to evaluate hepatic metastatic spread and localization before CT-guided RFA and for follow-up after intervention. Sixteen of these patients (65.1 {+-} 10.3 years) with 30 metastases stayed tumor-free (group 1), while the other group (n = 16 with 24 metastases; 62.0 {+-} 13.8 years) suffered from local recurrent disease (group 2). Applying an automated software tool (SyngoCT Oncology; Siemens Healthcare, Forchheim, Germany), size parameters (volume, RECIST, WHO) and attenuation were measured within the lesions before, 1 day after, and 28 days after RFA treatment. The natural logarithm (ln) of the quotient of the volume 1 day versus 28 days after RFA treament was computed: lnQ1//28/0{sub volume}. Analogously, ln ratios of RECIST, WHO, and attenuation were computed and statistically evaluated by repeated-measures ANOVA. One lesion in group 2 was excluded from further evaluation due to automated missegmentation. Statistically significant differences between the two groups were observed with respect to initial volume, RECIST, and WHO (p < 0.05). Furthermore, ln ratios corresponding to volume, RECIST, and WHO differed significantly between the two groups. Attenuation evaluations showed no significant differences, but there was a trend toward attenuation assessment for the parameter lnQ28/0{sub attenuation} (p = 0.0527), showing higher values for group 1 (-0.4 {+-} 0.3) compared to group 2 (-0.2 {+-} 0.2). In conclusion, hepatic metastases and their zone of coagulation necrosis after RFA differed significantly between tumor

  6. Design and evaluation of an oxidant-fuel-ratio-zoned rocket injector for high performance and ablative engine compatibility

    NASA Technical Reports Server (NTRS)

    Winter, J. M.; Pavli, A. J.; Shinn, A. M., Jr.

    1972-01-01

    A method for temperature control of the combustion gases in the peripheral zone of a rocket combustor which would reduce ablative throat erosion, prevent melting of zirconia throat inserts, and maintain high combustion performance is discussed. Included are techniques for analyzing and predicting zoned injector performance, as well as the philosophy and method for accomplishing an optimum compromise between high performance and reduced effective gas temperature. The experimental work was done with a 1000-lbf rocket engine which used as propellants N2O4 and a blend of 50-percent N2H4 and 50-percent UDMH at 100-psia chamber pressure and an overall O/F of 2.0. The method selected to provide temperature control was to use 30 percent of the propellant to form a peripheral zone of combustion gases at an O/F of 1.31 and 2700 K. The remaining 70 percent of the propellant in the core was at an O/F of 2.45 to keep the overall O/F at 2.0.

  7. Comparison of ablation defect on MR imaging with computer simulation estimated treatment zone following irreversible electroporation of patient prostate.

    PubMed

    Srimathveeravalli, Govindarajan; Cornelis, Francois; Mashni, Joseph; Takaki, Haruyuki; Durack, Jeremy C; Solomon, Stephen B; Coleman, Jonathan A

    2016-01-01

    To determine whether patient specific numerical simulations of irreversible electroporation (IRE) of the prostate correlates with the treatment effect seen on follow-up MR imaging. Computer models were created using intra-operative US images, post-treatment follow-up MR images and clinical data from six patients receiving IRE. Isoelectric contours drawn using simulation results were compared with MR imaging to estimate the energy threshold separating treated and untreated tissue. Simulation estimates of injury to the neurovascular bundle and rectum were compared with clinical follow-up and patient reported outcomes. At the electric field strength of 700 V/cm, simulation estimated electric field distribution was not different from the ablation defect seen on follow-up MR imaging (p = 0.43). Simulation predicted cross sectional area of treatment (mean 532.33 ± 142.32 mm(2)) corresponded well with the treatment zone seen on MR imaging (mean 540.16 ± 237.13 mm(2)). Simulation results did not suggest injury to the rectum or neurovascular bundle, matching clinical follow-up at 3 months. Computer simulation estimated zone of irreversible electroporation in the prostate at 700 V/cm was comparable to measurements made on follow-up MR imaging. Numerical simulation may aid treatment planning for irreversible electroporation of the prostate in patients.

  8. Local recurrence of small cell lung cancer following radiofrequency ablation is induced by HIF-1α expression in the transition zone

    PubMed Central

    WAN, JUN; WU, WEI; ZHANG, RENQUAN

    2016-01-01

    Local recurrence of lung cancer following radiofrequency ablation (RFA) treatment is common. The aims of the present study were to assess how RFA treatment affects the growth of small cell lung cancer (SCLC) micrometastases in the transition zone (TZ) surrounding the ablated region and in the reference zones (RZs) of the ablated or unablated lobes and to identify the molecular mechanism(s) of lung cancer recurrence following RFA treatment. After lung micrometastases of human SCLCs had formed, RFA treatment was applied to the right upper lobe (RUL) of the lung in nude mice. Hypoxia inducible factor (HIF)-1α expression, proliferation and angiogenesis potential both in the TZ and RZ were evaluated over time. Separately, at day 1, 7 and 14 following RFA treatment, the growth of micrometastases showed an ~2-fold increase in the TZ compared to the RZ of the unablated lobe, as the right lower lobe (RLL) and the growth of micrometastases in the RZ of the RUL was also induced by RFA. In addition, accelerated tumor growth in the TZ was induced by HIF-1α, but was not associated with tissue angiogenesis potential. We concluded that local recurrences of SCLCs caused by overproliferation of micrometastases following RFA treatment were driven by HIF-1α, although angiogenesis was not the driving force in the TZ. PMID:26750332

  9. "Sub Specie Boni": The Comfort Zone of Self-Belief--A Dimension in Counseling Offenders.

    ERIC Educational Resources Information Center

    Church, James Lee

    1996-01-01

    Claims that self-defeating behavior is a rational attempt to satisfy early, introjected messages about the type of person one is, arising from a desire for things perceived as good--sub specie boni. Examines the notion of the comfort zone, toxic shame, and therapists' responsibility to nourish acceptable joy. (RJM)

  10. Thermal Ablation of Lung Tissue: In Vivo Experimental Comparison of Microwave and Radiofrequency

    SciTech Connect

    Crocetti, Laura Bozzi, Elena; Faviana, Pinuccia; Cioni, Dania; Della Pina, Clotilde; Sbrana, Alberto; Fontanini, Gabriella; Lencioni, Riccardo

    2010-08-15

    This study was designed to compare feasibility, safety, and effectiveness of microwave (MW) ablation versus radiofrequency (RF) ablation of lung tissue in a rabbit model. Twenty New Zealand White rabbits were submitted to MW (n = 10, group A) or RF ablation (n = 10, group B). The procedures were performed with a prototype MW ablation device with a 1.6-cm radiating section antenna (Valleylab MW Ablation System) and with a 2-cm exposed-tip RF electrode (Cool-tip RF Ablation System). At immediate computed tomography increase in density, maximum diameters (D1-D3) of ablation zones were measured and ablation volume was calculated. Histopathologic assessment was performed 3 and 7 days after the procedure. Technical success was achieved in nine of 10 rabbits in each group. One death occurred in group B. Complications included pneumothorax (group A, n = 4; group B, n = 4), abscess (group A, n = 1; group B, n = 1), and thoracic wall burn (group A, n = 4). No significant differences were demonstrated in attenuation increase (P = 0.73), dimensions (P = 0.28, 0.86, 0.06, respectively, comparing D1-D3) and volume (P = 0.17). At histopathology, ablation zones were similar, with septal necrosis, edema, hemorrhage, and peripheral lymphocytic infiltrate. Complete thrombosis of more than 90% of vessels up to 2 mm in diameter was depicted at the periphery of the ablation zone in group A specimens. In group B specimens, complete thrombosis was depicted in 20% of vessels. Feasibility and safety of MW and RF ablation are similar in a lung rabbit model. MW ablation produces a greater damage to peripheral small vessels inducing thrombosis.

  11. Modelling of transient river - aquifer exchange using pressure head and heat measurements: the hyporheic zone's dimension

    NASA Astrophysics Data System (ADS)

    Nuetzmann, Gunnar; Christian, Levers; Jörg, Lewandowski

    2010-05-01

    Water exchange processes in the floodplain of a lowland groundwater-surface water system are studied on the basis of a study site near Freienbrink, NE Germany. The surface water boundaries of this site are formed by an oxbow and the current bed of the river Spree, section Müggelspree. Surface and ground water levels and water temperatures were collected in 12 piezometers and 2 recording stage gauges of a 300 m long transect throughout a one-year-period. Due to water level fluctuations alternation of infiltration and exfiltration occurred. However, most of the time groundwater flux is directed into the river Spree and, river water infiltration events into the aquifer are usually short and of minor importance. Due to clogging of the oxbow bed with a mud layer of different thickness the hydraulic contact between the oxbow and the adjacent aquifer is heterogeneously distributed and partially marginal. These features are modelled quantitatively using SUTRA in order to simulate coupled ground water flow and heat transport. A two-dimensional vertical modelling approach along the piezometer transect is developed to study exchange processes close to the surface water bodies more in detail in order to quantify the hyporheic fluxes of both river sections and to identify the directions and quantities of mass and heat fluxes. With the results the following questions will be answered: (1) It is possible to identify and to quantify the hydraulic processes (in- and exfiltration) between both river sections and the aquifer? (2) How fast does the exchange between the surface water and the aquifer occur? (3) Is there a hyporheic zone between the river sections and the aquifer, where groundwater and surface water are mixed, and how much water and heat will be transferred through this zones?

  12. Probabilistic finite element analysis of radiofrequency liver ablation using the unscented transform

    NASA Astrophysics Data System (ADS)

    dos Santos, Icaro; Haemmerich, Dieter; Schutt, David; Ferreira da Rocha, Adson; Rax Menezes, Leonardo

    2009-02-01

    The main limitation of radiofrequency (RF) ablation numerical simulations reported in the literature is their failure to provide statistical results based on the statistical variability of tissue thermal-electrical parameters. This work developed an efficient probabilistic approach to hepatic RF ablation in order to statistically evaluate the effect of four thermal-electrical properties of liver tissue on the uncertainty of the ablation zone dimensions: thermal conductivity, specific heat, blood perfusion and electrical conductivity. A deterministic thermal-electrical finite element model of a monopolar electrode inserted in the liver was coupled with the unscented transform method in order to obtain coagulation zone confidence intervals, probability and cumulative density functions. The coagulation zone volume, diameter and length were 10.96 cm3, 2.17 cm and 4.08 cm, respectively (P < 0.01). Furthermore, a probabilistic sensitivity analysis showed that perfusion and thermal conductivity account for >95% of the variability in coagulation zone volume, diameter and length.

  13. CT imaging during microwave ablation: Analysis of spatial and temporal tissue contraction

    SciTech Connect

    Liu, Dong; Brace, Christopher L.

    2014-11-01

    Purpose: To analyze the spatial distribution and temporal development of liver tissue contraction during high-temperature ablation by using intraprocedural computed tomography (CT) imaging. Methods: A total of 46 aluminum fiducial markers were positioned in a 60 × 45 mm grid, in a single plane, around a microwave ablation antenna in each of six ex vivo bovine liver samples. Ablations were performed for 10 min at 100 W. CT data of the liver sample were acquired every 30 s during ablation. Fiducial motion between acquisitions was tracked in postprocessing and used to calculate measures of tissue contraction and contraction rates. The spatial distribution and temporal evolution of contraction were analyzed. Results: Fiducial displacement indicated that the zone measured postablation was 8.2 ± 1.8 mm (∼20%) smaller in the radial direction and 7.1 ± 1.0 mm (∼10%) shorter in the longitudinal direction than the preablation tissue dimension. Therefore, the total ablation volume was reduced from its preablation value by approximately 45%. Very little longitudinal contraction was noted in the distal portion of the ablation zone. Central tissues contracted more than 60%, which was near an estimated limit of ∼70% based on initial water content. More peripheral tissues contracted only 15% in any direction. Contraction rates peaked during the first 60 s of heating with a roughly exponential decay over time. Conclusions: Ablation zones measured posttreatment are significantly smaller than the pretreatment tissue dimensions. Tissue contraction is spatially dependent, with the greatest effect occurring in the central ablation zone. Contraction rate peaks early and decays over time.

  14. Modeling and validation of microwave ablations with internal vaporization.

    PubMed

    Chiang, Jason; Birla, Sohan; Bedoya, Mariajose; Jones, David; Subbiah, Jeyam; Brace, Christopher L

    2015-02-01

    Numerical simulation is increasingly being utilized for computer-aided design of treatment devices, analysis of ablation growth, and clinical treatment planning. Simulation models to date have incorporated electromagnetic wave propagation and heat conduction, but not other relevant physics such as water vaporization and mass transfer. Such physical changes are particularly noteworthy during the intense heat generation associated with microwave heating. In this paper, a numerical model was created that integrates microwave heating with water vapor generation and transport by using porous media assumptions in the tissue domain. The heating physics of the water vapor model was validated through temperature measurements taken at locations 5, 10, and 20 mm away from the heating zone of the microwave antenna in homogenized ex vivo bovine liver setup. Cross-sectional area of water vapor transport was validated through intraprocedural computed tomography (CT) during microwave ablations in homogenized ex vivo bovine liver. Iso-density contours from CT images were compared to vapor concentration contours from the numerical model at intermittent time points using the Jaccard index. In general, there was an improving correlation in ablation size dimensions as the ablation procedure proceeded, with a Jaccard index of 0.27, 0.49, 0.61, 0.67, and 0.69 at 1, 2, 3, 4, and 5 min, respectively. This study demonstrates the feasibility and validity of incorporating water vapor concentration into thermal ablation simulations and validating such models experimentally. PMID:25330481

  15. Modeling and validation of microwave ablations with internal vaporization.

    PubMed

    Chiang, Jason; Birla, Sohan; Bedoya, Mariajose; Jones, David; Subbiah, Jeyam; Brace, Christopher L

    2015-02-01

    Numerical simulation is increasingly being utilized for computer-aided design of treatment devices, analysis of ablation growth, and clinical treatment planning. Simulation models to date have incorporated electromagnetic wave propagation and heat conduction, but not other relevant physics such as water vaporization and mass transfer. Such physical changes are particularly noteworthy during the intense heat generation associated with microwave heating. In this paper, a numerical model was created that integrates microwave heating with water vapor generation and transport by using porous media assumptions in the tissue domain. The heating physics of the water vapor model was validated through temperature measurements taken at locations 5, 10, and 20 mm away from the heating zone of the microwave antenna in homogenized ex vivo bovine liver setup. Cross-sectional area of water vapor transport was validated through intraprocedural computed tomography (CT) during microwave ablations in homogenized ex vivo bovine liver. Iso-density contours from CT images were compared to vapor concentration contours from the numerical model at intermittent time points using the Jaccard index. In general, there was an improving correlation in ablation size dimensions as the ablation procedure proceeded, with a Jaccard index of 0.27, 0.49, 0.61, 0.67, and 0.69 at 1, 2, 3, 4, and 5 min, respectively. This study demonstrates the feasibility and validity of incorporating water vapor concentration into thermal ablation simulations and validating such models experimentally.

  16. Modeling and Validation of Microwave Ablations with Internal Vaporization

    PubMed Central

    Chiang, Jason; Birla, Sohan; Bedoya, Mariajose; Jones, David; Subbiah, Jeyam; Brace, Christopher L.

    2014-01-01

    Numerical simulation is increasingly being utilized for computer-aided design of treatment devices, analysis of ablation growth, and clinical treatment planning. Simulation models to date have incorporated electromagnetic wave propagation and heat conduction, but not other relevant physics such as water vaporization and mass transfer. Such physical changes are particularly noteworthy during the intense heat generation associated with microwave heating. In this work, a numerical model was created that integrates microwave heating with water vapor generation and transport by using porous media assumptions in the tissue domain. The heating physics of the water vapor model was validated through temperature measurements taken at locations 5, 10 and 20 mm away from the heating zone of the microwave antenna in homogenized ex vivo bovine liver setup. Cross-sectional area of water vapor transport was validated through intra-procedural computed tomography (CT) during microwave ablations in homogenized ex vivo bovine liver. Iso-density contours from CT images were compared to vapor concentration contours from the numerical model at intermittent time points using the Jaccard Index. In general, there was an improving correlation in ablation size dimensions as the ablation procedure proceeded, with a Jaccard Index of 0.27, 0.49, 0.61, 0.67 and 0.69 at 1, 2, 3, 4, and 5 minutes. This study demonstrates the feasibility and validity of incorporating water vapor concentration into thermal ablation simulations and validating such models experimentally. PMID:25330481

  17. Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment.

    PubMed

    Watanabe, Hiroki; Yamazaki, Nozomu; Isobe, Yosuke; Lu, XiaoWei; Kobayashi, Yo; Miyashita, Tomoyuki; Ohdaira, Takeshi; Hashizume, Makoto; Fujie, Masakatsu G

    2012-01-01

    Radiofrequency (RF) ablation is increasingly used to treat cancer because it is minimally invasive. However, it is difficult for operators to control precisely the formation of coagulation zones because of the inadequacies of imaging modalities. To overcome this limitation, we previously proposed a model-based robotic ablation system that can create the required size and shape of coagulation zone based on the dimensions of the tumor. At the heart of such a robotic system is a precise temperature distribution simulator for RF ablation. In this article, we evaluated the simulation accuracy of two numerical simulation liver models, one using a constant thermal conductivity value and the other using temperature-dependent thermal conductivity values, compared with temperatures obtained using in vitro experiments. The liver model that reflected the temperature dependence of thermal conductivity did not result in a large increase of simulation accuracy compared with the temperature-independent model in the temperature range achieved during clinical RF ablation.

  18. Rates of burial and exhumation of lawsonite blueschist/eclogite in subduction zones from in situ UV laser ablation 40Ar/39Ar phengite geochronology

    NASA Astrophysics Data System (ADS)

    Fornash, K.; Cosca, M. A.; Whitney, D. L.; Teyssier, C. P.

    2014-12-01

    Lawsonite eclogites and blueschists are accessible records of processes that occur at depth in subducting slabs and can therefore provide information about the chemical and physical evolution of subduction zones. In composite blueschist-eclogite terranes, blueschists may have formed (1) by prograde metamorphism (pre-eclogite), (2) at the same P-T conditions as eclogite-facies metamorphism as a result of differences in bulk composition, H2O content, or oxidation state, or (3) from retrogression of eclogite, e.g. during exhumation. Field and petrologic observations of lawsonite eclogite and blueschist in the Sivrihisar Massif, Turkey, suggest that some blueschist formed from eclogite during exhumation in the subduction channel, whereas results from thermobarometry suggest that some blueschist formed at the same P-T conditions as eclogite. To test the age, petrologic, and tectonic relationship of coexisting eclogite and blueschist, we applied in situ UV laser ablation 40Ar/39Ar phengite geochronology to eclogite- and blueschist-facies rocks representing different structural positions and displaying different phengite textures and coexisting mineral assemblages. Phengite from fresh lawsonite eclogite yield an age of 93 ± 2 Ma and have the narrowest spread in ages (<12 Ma) of any rock type analyzed. Retrogressed (epidote) eclogite yields a mean weighted age of 82 ± 2 Ma. In contrast to the tightly constrained ages obtained in eclogite pods, blueschists and blueschist-facies quartzite exhibit discrete age populations ranging from 82 Ma to 110 Ma. Deformed phengite clusters from lawsonite garnet blueschist record age populations at 82 Ma and 92 Ma. Phengite from lawsonite-garnet veins and glaucophane-rich margins of eclogite pods also record 92 Ma. Omphacite-bearing lawsonite blueschist and a blueschist-facies quartzite from the same structural position contain age populations at 97 Ma and 110 Ma. These results document a sequence of events from prograde blueschist

  19. Microwave Ablation Compared with Radiofrequency Ablation for Breast Tissue in an Ex Vivo Bovine Udder Model

    SciTech Connect

    Tanaka, Toshihiro; Westphal, Saskia; Isfort, Peter; Braunschweig, Till; Penzkofer, Tobias Bruners, Philipp; Kichikawa, Kimihiko; Schmitz-Rode, Thomas Mahnken, Andreas H.

    2012-08-15

    Purpose: To compare the effectiveness of microwave (MW) ablation with radiofrequency (RF) ablation for treating breast tissue in a nonperfused ex vivo model of healthy bovine udder tissue. Materials and Methods: MW ablations were performed at power outputs of 25W, 35W, and 45W using a 915-MHz frequency generator and a 2-cm active tip antenna. RF ablations were performed with a bipolar RF system with 2- and 3-cm active tip electrodes. Tissue temperatures were continuously monitored during ablation. Results: The mean short-axis diameters of the coagulation zones were 1.34 {+-} 0.14, 1.45 {+-} 0.13, and 1.74 {+-} 0.11 cm for MW ablation at outputs of 25W, 35W, and 45W. For RF ablation, the corresponding values were 1.16 {+-} 0.09 and 1.26 {+-} 0.14 cm with electrodes having 2- and 3-cm active tips, respectively. The mean coagulation volumes were 2.27 {+-} 0.65, 2.85 {+-} 0.72, and 4.45 {+-} 0.47 cm{sup 3} for MW ablation at outputs of 25W, 35W, and 45W and 1.18 {+-} 0.30 and 2.29 {+-} 0.55 cm{sup 3} got RF ablation with 2- and 3-cm electrodes, respectively. MW ablations at 35W and 45W achieved significantly longer short-axis diameters than RF ablations (P < 0.05). The highest tissue temperature was achieved with MW ablation at 45W (P < 0.05). On histological examination, the extent of the ablation zone in MW ablations was less affected by tissue heterogeneity than that in RF ablations. Conclusion: MW ablation appears to be advantageous with respect to the volume of ablation and the shape of the margin of necrosis compared with RF ablation in an ex vivo bovine udder.

  20. [Ablative and fractional lasers].

    PubMed

    Beylot, C; Grognard, C; Michaud, T

    2009-10-01

    The use of pulsed or scanning Carbon Dioxide, and pulsed Erbium-YAG lasers allows the programmable and reproducible photocoagulation of thin layers of the epidermis and superficial dermis. Thermal damage depends on the type of laser and is greater with CO(2) lasers. The degree of neocollagenesis is proportional to the thermal damage and is better with CO(2) lasers. Their main indication is the correction of photoaged facial skin but they can also be used for corrective dermatology, e.g. for scars and genodermatosis. Results are highly satisfactory but the technique is invasive and the patient experiences a social hindrance of around two weeks. Fractionated techniques treat 25% of the defective skin area at each session in noncontiguous microzones; four sessions are therefore necessary to treat the entire cutaneous surface. The treatment is given under topical anesthesia and is much less invasive, particularly with nonablative fractional laser treatment in which photothermolysis does not penetrate below the epidermis and/or the effects are slight, with no or very little social isolation. However, the results are much less satisfactory than the results of ablative laser and there is no firming effect. Other zones than the face can be treated. With the fractional CO(2) and Erbium ablative lasers, which have multiplied over the past 2 years, the much wider impacts cause perforation of the epidermis and there is a zone of ablation by laser photovaporization, with a zone of thermal damage below. The results are better in correcting photoaging of the face, without, however, achieving the efficacy of ablative lasers, which remain the reference technique. However, the effects are not insignificant, requiring at least 5 days of social isolation.

  1. Features and dimensions of the Hayward Fault Zone in the Strawberry and Blackberry Creek Area, Berkeley, California

    SciTech Connect

    Williams, P.L.

    1995-03-01

    This report presents an examination of the geometry of the Hayward fault adjacent to the Lawrence Berkeley Laboratory and University of California campuses in central Berkeley. The fault crosses inside the eastern border of the UC campus. Most subtle geomorphic (landform) expressions of the fault have been removed by development and by the natural processes of landsliding and erosion. Some clear expressions of the fault remain however, and these are key to mapping the main trace through the campus area. In addition, original geomorphic evidence of the fault`s location was recovered from large scale mapping of the site dating from 1873 to 1897. Before construction obscured and removed natural landforms, the fault was expressed by a linear, northwest-tending zone of fault-related geomorphic features. There existed well-defined and subtle stream offsets and beheaded channels, fault scarps, and a prominent ``shutter ridge``. To improve our confidence in fault locations interpreted from landforms, we referred to clear fault exposures revealed in trenching, revealed during the construction of the Foothill Housing Complex, and revealed along the length of the Lawson Adit mining tunnel. Also utilized were the locations of offset cultural features. At several locations across the study area, distress features in buildings and streets have been used to precisely locate the fault. Recent published mapping of the fault (Lienkaemper, 1992) was principally used for reference to evidence of the fault`s location to the northwest and southeast of Lawrence Berkeley Laboratory.

  2. Larger low voltage zone in endocardial unipolar map compared with that in epicardial bipolar map indicates difficulty in eliminating ventricular tachycardia by catheter ablation.

    PubMed

    Miyamoto, Koji; Noda, Takashi; Satomi, Kazuhiro; Wada, Mitsuru; Nakajima, Ikutaro; Ishibashi, Kohei; Okamura, Hideo; Noguchi, Teruo; Anzai, Toshihisa; Yasuda, Satoshi; Ogawa, Hisao; Shimizu, Wataru; Aiba, Takeshi; Kamakura, Shiro; Kusano, Kengo

    2016-08-01

    Patients with ischemic and non-ischemic cardiomyopathy often have substrate for ventricular tachycardia (VT) in the endocardium (ENDO), epicardium (EPI), and/or intramural. Although it has been reported that the ENDO unipolar (UNI) voltage map is useful in detecting EPI substrate, its feasibility to detect intramural scarring and its usefulness in radiofrequency catheter ablation (RFCA) remain unclear. To assess the relationship between the left ventricle (LV) ENDO UNI voltage map and the LV EPI bipolar (BIP) voltage map, and to determine the usefulness of the ENDO UNI voltage map to guide RFCA for VT in patients with cardiomyopathy undergoing combined ENDO- and EPI RFCA. Eleven patients with VT undergoing detailed ENDO and EPI electroanatomical mapping of the LV were included (mean age 59 ± 11 years, 9 men). We assessed the value of the LV ENDO UNI voltage map in identifying EPI and/or intramural substrate in these 11 patients with non-ischemic or ischemic cardiomyopathy. The underlying heart disease was dilated cardiomyopathy in 4 patients, cardiac sarcoidosis in 3, hypertrophic cardiomyopathy in 2, and ischemic heart disease in 2 patients. The mean LV ejection fraction was 24 ± 7 %. The low voltage zone (LVZ) was defined as <1.5 mV for LV ENDO BIP electrograms (EGMs), <8.3 mV for LV ENDO UNI EGMs, and <1.0 mV for LV EPI BIP EGMs. The surface area of each LVZ was measured. We also measured the LVZ of the spatial overlap between ENDO UNI and EPI BIP voltage maps using the transparency mode on CARTO software. We performed RFCA at the ENDO and EPI based on activation and/or substrate maps, targeting the LVZ and/or abnormal EGMs. The LVZ was present in the LV ENDO BIP voltage map in 10 of 11 patients (42 ± 33 cm(2)), and in the LV ENDO UNI voltage map in 10 of 11 patients (72 ± 45 cm(2)). The LVZ was present in the EPI BIP voltage map in 9 of 11 patients (70 ± 61 cm(2)), and the LVZ in the ENDO UNI voltage map was also seen in all 9 patients

  3. Larger low voltage zone in endocardial unipolar map compared with that in epicardial bipolar map indicates difficulty in eliminating ventricular tachycardia by catheter ablation.

    PubMed

    Miyamoto, Koji; Noda, Takashi; Satomi, Kazuhiro; Wada, Mitsuru; Nakajima, Ikutaro; Ishibashi, Kohei; Okamura, Hideo; Noguchi, Teruo; Anzai, Toshihisa; Yasuda, Satoshi; Ogawa, Hisao; Shimizu, Wataru; Aiba, Takeshi; Kamakura, Shiro; Kusano, Kengo

    2016-08-01

    Patients with ischemic and non-ischemic cardiomyopathy often have substrate for ventricular tachycardia (VT) in the endocardium (ENDO), epicardium (EPI), and/or intramural. Although it has been reported that the ENDO unipolar (UNI) voltage map is useful in detecting EPI substrate, its feasibility to detect intramural scarring and its usefulness in radiofrequency catheter ablation (RFCA) remain unclear. To assess the relationship between the left ventricle (LV) ENDO UNI voltage map and the LV EPI bipolar (BIP) voltage map, and to determine the usefulness of the ENDO UNI voltage map to guide RFCA for VT in patients with cardiomyopathy undergoing combined ENDO- and EPI RFCA. Eleven patients with VT undergoing detailed ENDO and EPI electroanatomical mapping of the LV were included (mean age 59 ± 11 years, 9 men). We assessed the value of the LV ENDO UNI voltage map in identifying EPI and/or intramural substrate in these 11 patients with non-ischemic or ischemic cardiomyopathy. The underlying heart disease was dilated cardiomyopathy in 4 patients, cardiac sarcoidosis in 3, hypertrophic cardiomyopathy in 2, and ischemic heart disease in 2 patients. The mean LV ejection fraction was 24 ± 7 %. The low voltage zone (LVZ) was defined as <1.5 mV for LV ENDO BIP electrograms (EGMs), <8.3 mV for LV ENDO UNI EGMs, and <1.0 mV for LV EPI BIP EGMs. The surface area of each LVZ was measured. We also measured the LVZ of the spatial overlap between ENDO UNI and EPI BIP voltage maps using the transparency mode on CARTO software. We performed RFCA at the ENDO and EPI based on activation and/or substrate maps, targeting the LVZ and/or abnormal EGMs. The LVZ was present in the LV ENDO BIP voltage map in 10 of 11 patients (42 ± 33 cm(2)), and in the LV ENDO UNI voltage map in 10 of 11 patients (72 ± 45 cm(2)). The LVZ was present in the EPI BIP voltage map in 9 of 11 patients (70 ± 61 cm(2)), and the LVZ in the ENDO UNI voltage map was also seen in all 9 patients

  4. Radio Frequency Ablation in the Rabbit Lung Using Wet Electrodes: Comparison of Monopolar and Dual Bipolar Electrode Mode

    PubMed Central

    Park, Sang Hee; Han, Young Min; Chung, Gyung Ho; Kwak, Hyo Sung; Jeon, Soo bin; Lee, Yong Chul

    2006-01-01

    Objective To compare the effect of radio frequency ablation (RFA) on the dimensions of radio frequency coagulation necrosis in a rabbit lung using a wet electrode in monopolar mode with that in dual electrode bipolar mode at different infusion rates (15 mm/hr versus 30 ml/hr) and saline concentrations (0.9% normal versus 5.8% hypertonic saline). Materials and Methods Fifty ablation zones (one ablation zone in each rabbit) were produced in 50 rabbits using one or two 16-guage wet electrodes with a 1-cm active tip. The RFA system used in the monopolar and dual electrode wet bipolar RFA consisted of a 375-kHz generator (Elektrotom HiTT 106, Berchtold, Medizinelektronik, Germany). The power used was 30 watts and the exposure time was 5 minutes. The rabbits were assigned to one of five groups. Group A (n = 10) was infused with 0.9% NaCl used at a rate of 30 ml/hr in a monopolar mode. Groups B (n = 10) and C (n = 10) were infused with 0.9% NaCl at a rate of 15 and 30 ml/hr, respectively in dual electrode bipolar mode; groups D (n = 10) and E (n = 10) were infused with 5.8% NaCl at a rate of 15 and 30 ml/hr, respectively in a dual electrode bipolar mode. The dimensions of the ablation zones in the gross specimens from the groups were compared using one-way analysis of variance by means of the Scheffe test (post-hoc testing). Results The mean largest diameter of the ablation zones was larger in dual electrode bipolar mode (30.9±4.4 mm) than in monopolar mode (22.5±3.5 mm). The mean smallest diameter of the ablation zones was larger in dual electrode bipolar mode (22.3±2.5 mm) than in monopolar mode (19.5±3.5 mm). There were significant differences in the largest and smallest dimension between the monopolar (group A) and dual electrode wet bipolar mode (groups B-E). In dual electrode bipolar mode, the mean largest diameter of the ablation zones was larger at an infusion rate of 15 ml/hr (34.2±4.0 mm) than at 30 ml/hr (27.6±0.1 mm), and the mean smallest diameter of

  5. Ablative Thermal Protection: An Overview

    NASA Technical Reports Server (NTRS)

    Laub, Bernie

    2003-01-01

    Contents include the following: Why ablative thermal protections - TPS. Ablative TPS chronology: strategic reentry systems, solid rocket motor nozzles, space (manned missions and planetary entry probes). Ablation mechanisms. Ablation material testing. Ablative material testing.

  6. Femtosecond laser ablation of dentin and enamel: relationship between laser fluence and ablation efficiency

    NASA Astrophysics Data System (ADS)

    Chen, Hu; Liu, Jing; Li, Hong; Ge, Wenqi; Sun, Yuchun; Wang, Yong; Lü, Peijun

    2015-02-01

    The objective was to study the relationship between laser fluence and ablation efficiency of a femtosecond laser with a Gaussian-shaped pulse used to ablate dentin and enamel for prosthodontic tooth preparation. A diode-pumped thin-disk femtosecond laser with wavelength of 1025 nm and pulse width of 400 fs was used for the ablation of dentin and enamel. The laser spot was guided in a line on the dentin and enamel surfaces to form a groove-shaped ablation zone under a series of laser pulse energies. The width and volume of the ablated line were measured under a three-dimensional confocal microscope to calculate the ablation efficiency. Ablation efficiency for dentin reached a maximum value of 0.020 mm3/J when the laser fluence was set at 6.51 J/cm2. For enamel, the maximum ablation efficiency was 0.009 mm3/J at a fluence of 7.59 J/cm2. Ablation efficiency of the femtosecond laser on dentin and enamel is closely related to the laser fluence and may reach a maximum when the laser fluence is set to an appropriate value.

  7. Sphere-Enhanced Microwave Ablation (sMWA) Versus Bland Microwave Ablation (bMWA): Technical Parameters, Specific CT 3D Rendering and Histopathology

    SciTech Connect

    Gockner, T. L.; Zelzer, S.; Mokry, T. Gnutzmann, D. Bellemann, N.; Mogler, C.; Beierfuß, A. Köllensperger, E. Germann, G.; Radeleff, B. A. Stampfl, U. Kauczor, H. U.; Pereira, P. L.; Sommer, C. M.

    2015-04-15

    PurposeThis study was designed to compare technical parameters during ablation as well as CT 3D rendering and histopathology of the ablation zone between sphere-enhanced microwave ablation (sMWA) and bland microwave ablation (bMWA).MethodsIn six sheep-livers, 18 microwave ablations were performed with identical system presets (power output: 80 W, ablation time: 120 s). In three sheep, transarterial embolisation (TAE) was performed immediately before microwave ablation using spheres (diameter: 40 ± 10 μm) (sMWA). In the other three sheep, microwave ablation was performed without spheres embolisation (bMWA). Contrast-enhanced CT, sacrifice, and liver harvest followed immediately after microwave ablation. Study goals included technical parameters during ablation (resulting power output, ablation time), geometry of the ablation zone applying specific CT 3D rendering with a software prototype (short axis of the ablation zone, volume of the largest aligned ablation sphere within the ablation zone), and histopathology (hematoxylin-eosin, Masson Goldner and TUNEL).ResultsResulting power output/ablation times were 78.7 ± 1.0 W/120 ± 0.0 s for bMWA and 78.4 ± 1.0 W/120 ± 0.0 s for sMWA (n.s., respectively). Short axis/volume were 23.7 ± 3.7 mm/7.0 ± 2.4 cm{sup 3} for bMWA and 29.1 ± 3.4 mm/11.5 ± 3.9 cm{sup 3} for sMWA (P < 0.01, respectively). Histopathology confirmed the signs of coagulation necrosis as well as early and irreversible cell death for bMWA and sMWA. For sMWA, spheres were detected within, at the rim, and outside of the ablation zone without conspicuous features.ConclusionsSpecific CT 3D rendering identifies a larger ablation zone for sMWA compared with bMWA. The histopathological signs and the detectable amount of cell death are comparable for both groups. When comparing sMWA with bMWA, TAE has no effect on the technical parameters during ablation.

  8. Laser ablation of blepharopigmentation

    SciTech Connect

    Tanenbaum, M.; Karas, S.; McCord, C.D. Jr. )

    1988-01-01

    This article discusses laser ablation of blepharopigmentation in four stages: first, experimentally, where pigment vaporization is readily achieved with the argon blue-green laser; second, in the rabbit animal model, where eyelid blepharopigmentation markings are ablated with the laser; third, in human subjects, where the argon blue-green laser is effective in the ablation of implanted eyelid pigment; and fourth, in a case report, where, in a patient with improper pigment placement in the eyelid, the laser is used to safely and effectively ablate the undesired pigment markings. This article describes in detail the new technique of laser ablation of blepharopigmentation. Potential complications associated with the technique are discussed.

  9. Assessment of liver ablation using cone beam computed tomography

    PubMed Central

    Abdel-Rehim, Mohamed; Ronot, Maxime; Sibert, Annie; Vilgrain, Valérie

    2015-01-01

    AIM: To investigate the feasibility and accuracy of cone beam computed tomography (CBCT) in assessing the ablation zone after liver tumor ablation. METHODS: Twenty-three patients (17 men and 6 women, range: 45-85 years old, mean age 65 years) with malignant liver tumors underwent ultrasound-guided percutaneous tumor ablation [radiofrequency (n = 14), microwave (n = 9)] followed by intravenous contrast-enhanced CBCT. Baseline multidetector computed tomography (MDCT) and peri-procedural CBCT images were compared. CBCT image quality was assessed as poor, good, or excellent. Image fusion was performed to assess tumor coverage, and quality of fusion was rated as bad, good, or excellent. Ablation zone volumes on peri-procedural CBCT and post-procedural MDCT were compared using the non-parametric paired Wilcoxon t-test. RESULTS: Rate of primary ablation effectiveness was 100%. There were no complications related to ablation. Local tumor recurrence and new liver tumors were found 3 mo after initial treatment in one patient (4%). The ablation zone was identified in 21/23 (91.3%) patients on CBCT. The fusion of baseline MDCT and peri-procedural CBCT images was feasible in all patients and showed satisfactory tumor coverage (at least 5-mm margin). CBCT image quality was poor, good, and excellent in 2 (9%), 8 (35%), and 13 (56%), patients respectively. Registration quality between peri-procedural CBCT and post-procedural MDCT images was good to excellent in 17/23 (74%) patients. The median ablation volume on peri-procedural CBCT and post-procedural MDCT was 30 cm3 (range: 4-95 cm3) and 30 cm3 (range: 4-124 cm3), respectively (P-value > 0.2). There was a good correlation (r = 0.79) between the volumes of the two techniques. CONCLUSION: Contrast-enhanced CBCT after tumor ablation of the liver allows early assessment of the ablation zone. PMID:25593467

  10. Pulsed HF laser ablation of dentin

    NASA Astrophysics Data System (ADS)

    Papagiakoumou, Eirini I.; Papadopoulos, Dimitris N.; Makropoulou, Mersini I.; Khabbaz, Maruan G.; Serafetinides, Alexander A.

    2005-03-01

    The interaction of a TEA (Transversally Excited Atmospheric pressure) corona preionized oscillator double amplifier HF (hydrogen fluoride) laser beam with dentin tissue is reported. Pulses of 39 ns in the wavelength range of 2.65-3.35 μm and output energies in the range of 10-45 mJ, in a predominantly TEM00 beam were used to interact with dentin tissue. Ablation experiments were conducted with the laser beam directly focused on the tissue. Several samples of freshly extracted human teeth were used, cut longitudinally in facets of about 1mm thick and stored in phosphate buffered saline after being cleaned from the soft tissue remains. The experimental data (ablation thresholds, ablation rates) are discussed with respect to the ablation mechanism(s). Adequate tissue removal was observed and the ablation behavior was, in the greates part of the available fluences, almost linear. From the microscopic examination of teh samples, in a scanning electron microscope (SEM), the irradiated surfaces displayed oval craters (reflecting the laser beam shape) with absence of any melting or carbonization zone. It is suggested that the specific laser removes hard tissue by a combined photothermal and plasma mediated ablation mechanism, leaving a surface free from thermal damage and with a well-shaped crater.

  11. Combination of erbium and holmium laser radiation for tissue ablation

    NASA Astrophysics Data System (ADS)

    Pratisto, Hans S.; Frenz, Martin; Koenz, Flurin; Altermatt, Hans J.; Weber, Heinz P.

    1996-05-01

    Erbium lasers emitting at 2.94 micrometers and holmium lasers emitting at 2.1 micrometers are interesting tools for cutting, drilling, smoothing and welding of water containing tissues. The high absorption coefficient of water at these wavelengths leads to their good ablation efficiency with controlled thermally altered zones around the ablation sites. Combination of pulses with both wavelengths transmitted through one fiber were used to perform incisions in soft tissue and impacts in bone disks. Histological results and scanning electron microscope evaluations reveal the strong influence of the absorption coefficient on tissue effects, especially on the ablation efficiency and the zone of thermally damaged tissue. It is demonstrated that the combination of high ablation rates and deep coagulation zones can be achieved. The results indicate that this laser system can be considered as a first step towards a multi-functional medical instrument.

  12. Nonequilibrium Ablation of Phenolic Impregnated Carbon Ablator

    NASA Technical Reports Server (NTRS)

    Milos, Frank S.; Chen, Yih K.; Gokcen, Tahir

    2012-01-01

    In previous work, an equilibrium ablation and thermal response model for Phenolic Impregnated Carbon Ablator was developed. In general, over a wide range of test conditions, model predictions compared well with arcjet data for surface recession, surface temperature, in-depth temperature at multiple thermocouples, and char depth. In this work, additional arcjet tests were conducted at stagnation conditions down to 40 W/sq cm and 1.6 kPa. The new data suggest that nonequilibrium effects become important for ablation predictions at heat flux or pressure below about 80 W/sq cm or 10 kPa, respectively. Modifications to the ablation model to account for nonequilibrium effects are investigated. Predictions of the equilibrium and nonequilibrium models are compared with the arcjet data.

  13. Printable Nanophotonic Devices via Holographic Laser Ablation.

    PubMed

    Zhao, Qiancheng; Yetisen, Ali K; Sabouri, Aydin; Yun, Seok Hyun; Butt, Haider

    2015-09-22

    Holography plays a significant role in applications such as data storage, light trapping, security, and biosensors. However, conventional fabrication methods remain time-consuming, costly, and complex, limiting the fabrication of holograms and their extensive use. Here, we demonstrate a single-pulse laser ablation technique to write parallel surface gratings and Fresnel zone plates. We utilized a 6 ns high-energy green laser pulse to form interference patterns to record a surface grating with 820 nm periodicity and asymmetric zone plate holograms on 4.5 nm gold-coated substrates. The holographic recording process was completed within seconds. The optical characteristics of the interference patterns have been computationally modeled, and well-ordered polychromatic diffraction was observed from the fabricated holograms. The zone plate showed a significant diffraction angle of 32° from the normal incident for the focal point. The nanosecond laser interference ablation for rapid hologram fabrication holds great potential in a vast range of optical devices.

  14. Renal Ablation Update

    PubMed Central

    Khiatani, Vishal; Dixon, Robert G.

    2014-01-01

    Thermal ablative technologies have evolved considerably in the recent past and are now an important component of current clinical guidelines for the treatment of small renal masses. Both radiofrequency ablation and cryoablation have intermediate-term oncologic control that rivals surgical options, with favorable complication profiles. Studies comparing cryoablation and radiofrequency ablation show no significant difference in oncologic control or complication profile between the two modalities. Early data from small series with microwave ablation have shown similar promising results. Newer technologies including irreversible electroporation and high-intensity–focused ultrasound have theoretical advantages, but will require further research before becoming a routine part of the ablation armamentarium. The purpose of this review article is to discuss the current ablative technologies available, briefly review their mechanisms of action, discuss technical aspects of each, and provide current data supporting their use. PMID:25049445

  15. Radiofrequency Ablation of Cancer

    SciTech Connect

    Friedman, Marc; Mikityansky, Igor; Kam, Anthony; Libutti, Steven K.; Walther, McClellan M.; Neeman, Ziv; Locklin, Julia K.; Wood, Bradford J.

    2004-09-15

    Radiofrequency ablation (RFA) has been used for over 18 years for treatment of nerve-related chronic pain and cardiac arrhythmias. In the last 10 years, technical developments have increased ablation volumes in a controllable, versatile, and relatively inexpensive manner. The host of clinical applications for RFA have similarly expanded. Current RFA equipment, techniques, applications, results, complications, and research avenues for local tumor ablation are summarized.

  16. Stellar Ablation of Planetary Atmospheres

    NASA Technical Reports Server (NTRS)

    Moore, Thomas E.; Horwitz, J. L.

    2007-01-01

    We review observations and theories of the solar ablation of planetary atmospheres, focusing on the terrestrial case where a large magnetosphere holds off the solar wind, so that there is little direct atmospheric impact, but also couples the solar wind electromagnetically to the auroral zones. We consider the photothermal escape flows known as the polar wind or refilling flows, the enhanced mass flux escape flows that result from localized solar wind energy dissipation in the auroral zones, and the resultant enhanced neutral atom escape flows. We term these latter two escape flows the "auroral wind." We review observations and theories of the heating and acceleration of auroral winds, including energy inputs from precipitating particles, electromagnetic energy flux at magnetohydrodynamic and plasma wave frequencies, and acceleration by parallel electric fields and by convection pickup processes also known as "centrifugal acceleration." We consider also the global circulation of ionospheric plasmas within the magnetosphere, their participation in magnetospheric disturbances as absorbers of momentum and energy, and their ultimate loss from the magnetosphere into the downstream solar wind, loading reconnection processes that occur at high altitudes near the magnetospheric boundaries. We consider the role of planetary magnetization and the accumulating evidence of stellar ablation of extrasolar planetary atmospheres. Finally, we suggest and discuss future needs for both the theory and observation of the planetary ionospheres and their role in solar wind interactions, to achieve the generality required for a predictive science of the coupling of stellar and planetary atmospheres over the full range of possible conditions.

  17. Image-Guided Spinal Ablation: A Review.

    PubMed

    Tsoumakidou, Georgia; Koch, Guillaume; Caudrelier, Jean; Garnon, Julien; Cazzato, Roberto Luigi; Edalat, Faramarz; Gangi, Afshin

    2016-09-01

    The image-guided thermal ablation procedures can be used to treat a variety of benign and malignant spinal tumours. Small size osteoid osteoma can be treated with laser or radiofrequency. Larger tumours (osteoblastoma, aneurysmal bone cyst and metastasis) can be addressed with radiofrequency or cryoablation. Results on the literature of spinal microwave ablation are scarce, and thus it should be used with caution. A distinct advantage of cryoablation is the ability to monitor the ice-ball by intermittent CT or MRI. The different thermal insulation, temperature and electrophysiological monitoring techniques should be applied. Cautious pre-procedural planning and intermittent intra-procedural monitoring of the ablation zone can help reduce neural complications. Tumour histology, patient clinical-functional status and life-expectancy should define the most efficient and least disabling treatment option. PMID:27329231

  18. Sprayable lightweight ablative coating

    NASA Technical Reports Server (NTRS)

    Simpson, William G. (Inventor); Sharpe, Max H. (Inventor); Hill, William E. (Inventor)

    1991-01-01

    An improved lightweight, ablative coating is disclosed that may be spray applied and cured without the development of appreciable shrinkage cracks. The ablative mixture consists essentially of phenolic microballoons, hollow glass spheres, glass fibers, ground cork, a flexibilized resin binder, and an activated colloidal clay.

  19. Healing responses following cryothermic and hyperthermic tissue ablation

    NASA Astrophysics Data System (ADS)

    Godwin, Braden L.; Coad, James E.

    2009-02-01

    Minimally invasive, thermally ablative, interventional technologies have been changing the practice of medicine since before the turn of the 20th century. More recently, cryothermic and hyperthermic therapies have expanded in terms of their spectrum of thermal generators, modes for controlling and monitoring the treatment zone and both benign and malignant medical applications. The final tissue, and hence clinical outcome, of a thermal ablation is determined by the summation of direct primary (thermal) and secondary (apoptosis, ischemia, free radical, inflammation, wound healing, etc.) injury followed by possible cellular regeneration and scar formation. The initial thermal lesion can be broadly divided into two major zones of cellular death: 1) the complete ablation zone closer to the thermal source and 2) the peripheral transition zone with a decreasing gradient of cell death. While not applicable to cryotherapy, hyperthermic complete ablation zones are subdivided into two zones: 1) thermal or heat fixation and 2) coagulative necrosis. It is important to clearly differentiate these tissue zones because of their substantially different healing responses. Therefore, the development of clinically successful thermal therapies requires an understanding of tissue healing responses. The healing responses can be affected by a number of additional factors such as the tissue's anatomy, organ specific healing differences, blood supply, protein vs. lipid content, and other factors. Thus, effective biomedical instrument development requires both an understanding of thermal cell injury/death and the body's subsequent healing responses. This paper provides a general overview of the healing pathways that follow thermal tissue treatment.

  20. Finite-element analysis and in vitro experiments of placement configurations using triple antennas in microwave hepatic ablation.

    PubMed

    Phasukkit, Pattarapong; Tungjitkusolmun, Supan; Sangworasil, Manas

    2009-11-01

    This study presents analyses of triple-antenna configurations and designs for microwave (MW) hepatic ablation using 3-D finite-element (FE) analyses verified by in vitro experiments. Treatment of hepatic cancer often requires removal or destruction of large volume lesions. Using multiple antennas offers a potential solution for creating ablation zones with larger dimensions, as well as varied geometrical shapes. We performed both 3-D FE analyses and in vitro experiments using three identical open-tip MW antennas simultaneously, placing them in three types of configurations-"linear array," "triangular," and "T-shaped" arrangements. We compared coagulation volumes created, as well as temperature distribution characteristics, from the three-antenna arrangements after power delivery of 50 W for 60 s. We also performed additional tests using nonidentical antennas (open tip, slot, and slot with insulating jacket) for the three configurations. The results illustrate that arranging antennas in the "T-shaped" pattern destroyed more unwanted tissues than those found when using "linear array" and "triangular" arrangements, with maximum coagulation width and depth of 46 and 81 mm, respectively, and coagulation volume of 30.7 cm(3) . In addition, using nonidentical triple antennas caused variations in coagulation zone characteristics, and thus, the technique could be applied to treatment situations where nonsymmetric coagulation zones are required. PMID:19628446

  1. Finite-element analysis and in vitro experiments of placement configurations using triple antennas in microwave hepatic ablation.

    PubMed

    Phasukkit, Pattarapong; Tungjitkusolmun, Supan; Sangworasil, Manas

    2009-11-01

    This study presents analyses of triple-antenna configurations and designs for microwave (MW) hepatic ablation using 3-D finite-element (FE) analyses verified by in vitro experiments. Treatment of hepatic cancer often requires removal or destruction of large volume lesions. Using multiple antennas offers a potential solution for creating ablation zones with larger dimensions, as well as varied geometrical shapes. We performed both 3-D FE analyses and in vitro experiments using three identical open-tip MW antennas simultaneously, placing them in three types of configurations-"linear array," "triangular," and "T-shaped" arrangements. We compared coagulation volumes created, as well as temperature distribution characteristics, from the three-antenna arrangements after power delivery of 50 W for 60 s. We also performed additional tests using nonidentical antennas (open tip, slot, and slot with insulating jacket) for the three configurations. The results illustrate that arranging antennas in the "T-shaped" pattern destroyed more unwanted tissues than those found when using "linear array" and "triangular" arrangements, with maximum coagulation width and depth of 46 and 81 mm, respectively, and coagulation volume of 30.7 cm(3) . In addition, using nonidentical triple antennas caused variations in coagulation zone characteristics, and thus, the technique could be applied to treatment situations where nonsymmetric coagulation zones are required.

  2. Laser ablation of dyes

    NASA Astrophysics Data System (ADS)

    Späth, M.; Stuke, M.

    1992-01-01

    High density 50 μs pulses of the UV dyes PPF, POPOP and BBO and of two dyes in the visible region, Xanthen N92 and Fluorol 7GA were generated by laser ablation. Dye powders were pressed with 7800 kp/cm 2 in round pellets which were ablated by exposure to KrF excimer laser radiation (248 nm) at a fluence of 100 mJ/cm 2. The ablation cloud was optically activated with a XeCl excimer laser. Its fluorescence spectrum was measured and was identified as a dye vapour fluorescence spectrum by comparison to conventional dye solution and dye vapour spectra. The dye cloud is not deflected in an electric field (10 6 V/m). By changing the delay time between the ablation laser and the focused activation laser, the velocity distribution of the ablated dye was measured. Its maximum is at 600 m/s for PPF. Knowing the thickness of the ablated dye layer per shot (300 Å) and the size of the ablation cloud (pictures of a video camera), one can estimate the maximum density of the dye in the gas pulse to be 10 -5 mol/ l in the range of concentration of lasing dyes. However, no lasing was observed up to now.

  3. Tumor Ablation and Nanotechnology

    PubMed Central

    Manthe, Rachel L.; Foy, Susan P.; Krishnamurthy, Nishanth; Sharma, Blanka; Labhasetwar, Vinod

    2010-01-01

    Next to surgical resection, tumor ablation is a commonly used intervention in the treatment of solid tumors. Tumor ablation methods include thermal therapies, photodynamic therapy, and reactive oxygen species (ROS) producing agents. Thermal therapies induce tumor cell death via thermal energy and include radiofrequency, microwave, high intensity focused ultrasound, and cryoablation. Photodynamic therapy and ROS producing agents cause increased oxidative stress in tumor cells leading to apoptosis. While these therapies are safe and viable alternatives when resection of malignancies is not feasible, they do have associated limitations that prevent their widespread use in clinical applications. To improve the efficacy of these treatments, nanoparticles are being studied in combination with nonsurgical ablation regimens. In addition to better thermal effect on tumor ablation, nanoparticles can deliver anticancer therapeutics that show synergistic anti-tumor effect in the presence of heat and can also be imaged to achieve precision in therapy. Understanding the molecular mechanism of nanoparticle-mediated tumor ablation could further help engineer nanoparticles of appropriate composition and properties to synergize the ablation effect. This review aims to explore the various types of nonsurgical tumor ablation methods currently used in cancer treatment and potential improvements by nanotechnology applications. PMID:20866097

  4. Navigation Systems for Ablation

    PubMed Central

    Wood, B. J.; Kruecker, J.; Abi-Jaoudeh, N; Locklin, J.; Levy, E.; Xu, S.; Solbiati, L.; Kapoor, A.; Amalou, H.; Venkatesan, A.

    2010-01-01

    Navigation systems, devices and intra-procedural software are changing the way we practice interventional oncology. Prior to the development of precision navigation tools integrated with imaging systems, thermal ablation of hard-to-image lesions was highly dependent upon operator experience, spatial skills, and estimation of positron emission tomography-avid or arterial-phase targets. Numerous navigation systems for ablation bring the opportunity for standardization and accuracy that extends our ability to use imaging feedback during procedures. Existing systems and techniques are reviewed, and specific clinical applications for ablation are discussed to better define how these novel technologies address specific clinical needs, and fit into clinical practice. PMID:20656236

  5. Experiments on ocular tissue ablation at 5.3 and 6.0 {mu}m with the Los Alamos advanced FEL

    SciTech Connect

    Nguyen, D.C.; Ren, Q.; Hill, R.

    1995-12-31

    We investigated the ablation characteristics of a picosecond free-electron laser and compared its ablation effects on ocular tissues at 5.3 {mu}m and 6.0 {mu}m. The Advanced FEL at Los Alamos, operating in the wavelength range 4-6 {mu}m, was used for this study. The 10-{mu}s macropulse consisted of {approximately}1000 micropulses, each approximately 15 ps in length and separated from one another by 9.2 ns. The FEL beam was passed through a series of attenuator and focused to a 200-{mu}m spot in the sample with a 150-mm f.l. CaF{sub 2} lens. The energy in each macropulse ranged from 5 to 120 mJ. Five transplantable corneal-scleral buttons preserved in corneal storage media were used for this study. The tissue sample was positioned at the focused FEL beam for the ablation, and then fixed for histologic study. Corneal cuts made at 6.0 {mu}m revealed a well-defined ablation boundary. The measured lateral zone of the tissue damage was 11 {+-} 2 {mu}m. The integrity of the adjacent tissue was well maintained. By contrast, the ablation boundary of the corneal cuts made at 5.3 {mu}m appeared to be very disruptive. The collagen fiber near the ablation was thermally denatured and lost its organized structure. The lateral dimension of such effect extended out to 220 {mu}m beyond the intended cut into the surrounding tissues. We concluded that a short-pulsed laser operating at 6 {mu}m may be a potentially effective tool for cutting ocular tissues.

  6. Experimental Evaluation of the Heat Sink Effect in Hepatic Microwave Ablation

    PubMed Central

    Ringe, Kristina I.; Lutat, Carolin; Rieder, Christian; Schenk, Andrea; Wacker, Frank; Raatschen, Hans-Juergen

    2015-01-01

    Purpose To demonstrate and quantify the heat sink effect in hepatic microwave ablation (MWA) in a standardized ex vivo model, and to analyze the influence of vessel distance and blood flow on lesion volume and shape. Materials and Methods 108 ex vivo MWA procedures were performed in freshly harvested pig livers. Antennas were inserted parallel to non-perfused and perfused (700,1400 ml/min) glass tubes (diameter 5mm) at different distances (10, 15, 20mm). Ablation zones (radius, area) were analyzed and compared (Kruskal-Wallis Test, Dunn’s multiple comparison Test). Temperature changes adjacent to the tubes were measured throughout the ablation cycle. Results Maximum temperature decreased significantly with increasing flow and distance (p<0.05). Compared to non-perfused tubes, ablation zones were significantly deformed by perfused tubes within 15mm distance to the antenna (p<0.05). At a flow rate of 700ml/min ablation zone radius was reduced to 37.2% and 80.1% at 10 and 15mm tube distance, respectively; ablation zone area was reduced to 50.5% and 89.7%, respectively. Conclusion Significant changes of ablation zones were demonstrated in a pig liver model. Considerable heat sink effect was observed within a diameter of 15mm around simulated vessels, dependent on flow rate. This has to be taken into account when ablating liver lesions close to vessels. PMID:26222431

  7. Moldable cork ablation material

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A successful thermal ablative material was manufactured. Moldable cork sheets were tested for density, tensile strength, tensile elongation, thermal conductivity, compression set, and specific heat. A moldable cork sheet, therefore, was established as a realistic product.

  8. Laser ablation of concrete.

    SciTech Connect

    Savina, M.

    1998-10-05

    Laser ablation is effective both as an analytical tool and as a means of removing surface coatings. The elemental composition of surfaces can be determined by either mass spectrometry or atomic emission spectroscopy of the atomized effluent. Paint can be removed from aircraft without damage to the underlying aluminum substrate, and environmentally damaged buildings and sculptures can be restored by ablating away deposited grime. A recent application of laser ablation is the removal of radioactive contaminants from the surface and near-surface regions of concrete. We present the results of ablation tests on concrete samples using a high power pulsed Nd:YAG laser with fiber optic beam delivery. The laser-surface interaction was studied on various model systems consisting of Type I Portland cement with varying amounts of either fine silica or sand in an effort to understand the effect of substrate composition on ablation rates and mechanisms. A sample of non-contaminated concrete from a nuclear power plant was also studied. In addition, cement and concrete samples were doped with non-radioactive isotopes of elements representative of cooling waterspills, such as cesium and strontium, and analyzed by laser-resorption mass spectrometry to determine the contamination pathways. These samples were also ablated at high power to determine the efficiency with which surface contaminants are removed and captured. The results show that the neat cement matrix melts and vaporizes when little or no sand or aggregate is present. Surface flows of liquid material are readily apparent on the ablated surface and the captured aerosol takes the form of glassy beads up to a few tens of microns in diameter. The presence of sand and aggregate particles causes the material to disaggregate on ablation, with intact particles on the millimeter size scale leaving the surface. Laser resorption mass spectrometric analysis showed that cesium and potassium have similar chemical environments in the

  9. Dimension stone

    USGS Publications Warehouse

    Dolley, T.P.

    2003-01-01

    Dimension stone can be defined as natural rock material quarried to obtain blocks or slabs that meet specifications as to size (width, length and thickness) and shape for architectural or engineering purposes. Color, grain texture and pattern, and surface finish of the stone are also normal requirements. Other important selection criteria are durability (based on mineral composition, hardness and past performance), strength and the ability of the stone to take a polish.

  10. Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation

    PubMed Central

    Park, Mi-Hyun; Shin, Byung Seok; Jeon, Gyeong Sik; Lee, Byungmo; Lee, Kichang

    2012-01-01

    Background/Aims Various strategies to expand the ablation zone have been attempted using hepatic radiofrequency ablation (RFA). The optimal strategy, however, is unknown. We compared hepatic RFA with an internally cooled wet (ICW) electrode and vascular inflow occlusion. Methods Eight dogs were assigned to one of three groups: only RFA using an internally cooled electrode (group A), RFA using an ICW electrode (group B), and RFA using an internally cooled electrode with the Pringle maneuver (group C). The ablation zone diameters were measured on the gross specimens, and the volume of the ablation zone was calculated. Results The ablation zone volume was greatest in group B (1.82±1.23 cm3), followed by group C (1.22±0.47 cm3), and then group A (0.48±0.33 cm3). The volumes for group B were significantly larger than the volumes for group A (p=0.030). There was no significant difference in the volumes between groups A and C (p=0.079) and between groups B and C (p=0.827). Conclusions Both the usage of an ICW electrode and hepatic vascular occlusion effectively expanded the ablation zone. The use of an ICW electrode induced a larger ablation zone with easy handling compared with using hepatic vascular occlusion, although this difference was not statistically significant. PMID:23170152

  11. Multiple-antenna microwave ablation: analysis of non-parallel antenna implants

    NASA Astrophysics Data System (ADS)

    Mukherjee, Souvick; Curto, Sergio; Albin, Nathan; Natarajan, Bala; Prakash, Punit

    2015-03-01

    Microwave ablation is a minimally invasive modality increasingly being used for thermal treatment of cancer in various organs. During ablation procedures, treatment planning is typically restricted to vendor specifications of expected ablation zone volumes based on experiments in unperfused ex vivo tissues, presuming parallel insertion of antennas. However, parallel antenna implants are not always clinically possible due to the restricted control of flexible antennas and presence of intervening organs. This paper aims to quantify the effect of non-parallel antenna implants on the ablation volume. 3D electromagnetic-bioheat transfer models were implemented to analyze ablation zone profiles created by dual antenna arrays. Parallel and non-parallel implants spaced 10-25 mm with antenna tips deviated to create converging or diverging configurations were analyzed. Volumetric Dice Similarity Coefficients (DSC) were calculated to compare ablation zone volumes for parallel and non-parallel configuration. Antenna tip displacements of 3 mm/antenna yielded an average DSC of 0.78. Tip displacements of 5 mm/antenna yielded a DSC of 0.78 and 0.64 for 15 mm and 20 mm antenna spacing, respectively. For ablation with dipole antennas as the frequency of operation decreases from 2.45 GHz to 915 MHz the similarity between the ablation zones for parallel and angled cases increased significantly. In conclusion, ablation volumes with non-parallel antenna implants may differ significantly from the parallel configuration. Patient-specific treatment planning tools may provide more accurate predictions of 3D-ablation volumes based on imaging data of actual implanted antenna configurations. Methods to compare ablation zone volumes incorporating uncertainty in antenna positions and experimental results to validate the numerical modelling are also presented.

  12. Interferometric analysis of the ablation profile in refractive surgery

    NASA Astrophysics Data System (ADS)

    Rodríguez-Rodríguez, M. I.; López-Olazagasti, E.; Rosales, M. A.; Ramírez-Zavaleta, G.; Cantú, R.; Tepichín, E.

    2008-08-01

    In ophthalmology, the laser excimer corneal surface ablation used to correct the refractive eye defects, such as myopia, astigmatism and hyperopia and, more recently, presbyopia is known as refractive surgery. Typically, the characterization of the corresponding technique, as well as the laser accuracy, is performed by analyzing standard ablation profiles made on PMMA (polymethylmethacrylate) plates. A drawback of this technique is that those plates do not necessarily represent the dimensions of the cornea during the ablation. On the other hand, due to the time varying process of the eye aberrations, the direct eye refractometric measurements can produce some errors. We report in this work the interferometric analysis of the ablation profile obtained with refractive surgery, applied directly on a contact lens. In this case, the resultant ablation profile might be closer to the real profile as well as time invariant. We use, as a reference, a similar contact lens without ablation. The preliminary results of the characterization of the corresponding ablation profile are also presented.

  13. CT thermometry for cone-beam CT guided ablation

    NASA Astrophysics Data System (ADS)

    DeStefano, Zachary; Abi-Jaoudeh, Nadine; Li, Ming; Wood, Bradford J.; Summers, Ronald M.; Yao, Jianhua

    2016-03-01

    Monitoring temperature during a cone-beam CT (CBCT) guided ablation procedure is important for prevention of over-treatment and under-treatment. In order to accomplish ideal temperature monitoring, a thermometry map must be generated. Previously, this was attempted using CBCT scans of a pig shoulder undergoing ablation.1 We are extending this work by using CBCT scans of real patients and incorporating more processing steps. We register the scans before comparing them due to the movement and deformation of organs. We then automatically locate the needle tip and the ablation zone. We employ a robust change metric due to image noise and artifacts. This change metric takes windows around each pixel and uses an equation inspired by Time Delay Analysis to calculate the error between windows with the assumption that there is an ideal spatial offset. Once the change map is generated, we correlate change data with measured temperature data at the key points in the region. This allows us to transform our change map into a thermal map. This thermal map is then able to provide an estimate as to the size and temperature of the ablation zone. We evaluated our procedure on a data set of 12 patients who had a total of 24 ablation procedures performed. We were able to generate reasonable thermal maps with varying degrees of accuracy. The average error ranged from 2.7 to 16.2 degrees Celsius. In addition to providing estimates of the size of the ablation zone for surgical guidance, 3D visualizations of the ablation zone and needle are also produced.

  14. [Steam ablation of varicose veins].

    PubMed

    van den Bos, Renate R; Malskat, Wendy S J; Neumann, H A M Martino

    2013-01-01

    In many western countries endovenous thermal ablation techniques have largely replaced classical surgery for the treatment of saphenous varicose veins as they are more effective and patient friendly. Because these treatments can be performed under local tumescent anaesthesia, patients can mobilize immediately after the procedure. A new method of thermal ablation is endovenous steam ablation, which is a fast and easy procedure. Steam ablation may cause less pain than laser ablation and it is also cheaper and more flexible than segmental radiofrequency ablation. PMID:23484513

  15. Ablative therapies for renal tumors

    PubMed Central

    Ramanathan, Rajan; Leveillee, Raymond J.

    2010-01-01

    Owing to an increased use of diagnostic imaging for evaluating patients with other abdominal conditions, incidentally discovered kidney masses now account for a majority of renal tumors. Renal ablative therapy is assuming a more important role in patients with borderline renal impairment. Renal ablation uses heat or cold to bring about cell death. Radiofrequency ablation and cryoablation are two such procedures, and 5-year results are now emerging from both modalities. Renal biopsy at the time of ablation is extremely important in order to establish tissue diagnosis. Real-time temperature monitoring at the time of radiofrequency ablation is very useful to ensure adequacy of ablation. PMID:21789083

  16. Analysis of ablation debris from natural and artificial iron meteorites

    NASA Technical Reports Server (NTRS)

    Blanchard, M. B.; Davis, A. S.

    1977-01-01

    Artificial ablation studies were performed on iron and nickel-iron samples using an arc-heated plasma of ionized air. Experiment conditions simulated a meteoroid traveling about 12 km/sec at an altitude of 70 km. The artificially produced fusion crusts and ablation debris show features very similar to natural fusion crusts of the iron meteorites Boguslavka, Norfork, and N'Kandhla and to magnetic spherules recovered from Mn nodules. X-ray diffraction, electron microprobe, optical, and scanning electron microscope analyses reveal that important mineralogical, elemental, and textural changes occur during ablation. Some metal is melted and ablated. The outer margin of the melted rind is oxidized and recrystallizes as a discontinuous crust of magnetite and wustite. Adjacent to the oxidized metallic ablation zone is an unoxidized metallic ablation zone in which structures such as Widmannstatten bands are obliterated as the metal is transformed to unequilibrated alpha 2 nickel-iron. Volatile elements are vaporized and less volatile elements undergo fractionation.

  17. Nonlinear Analysis of Two-phase Circumferential Motion in the Ablation Circumstance

    NASA Astrophysics Data System (ADS)

    Xiao-liang, Xu; Hai-ming, Huang; Zi-mao, Zhang

    2010-05-01

    In aerospace craft reentry and solid rocket propellant nozzle, thermal chemistry ablation is a complex process coupling with convection, heat transfer, mass transfer and chemical reaction. Based on discrete vortex method (DVM), thermal chemical ablation model and particle kinetic model, a computational module dealing with the two-phase circumferential motion in ablation circumstance is designed, the ablation velocity and circumferential field can be thus calculated. The calculated nonlinear time series are analyzed in chaotic identification method: relative chaotic characters such as correlation dimension and the maximum Lyapunov exponent are calculated, fractal dimension of vortex bulbs and particles distributions are also obtained, thus the nonlinear ablation process can be judged as a spatiotemporal chaotic process.

  18. Real-time spectroscopic assessment of thermal damage: implications for radiofrequency ablation.

    PubMed

    Anderson, Christopher D; Lin, Wei-Chiang; Buttemere, Clay R; Washington, M Kay; Mahadevan-Jansen, Anita; Pierce, Janene; Nicoud, Ian B; Pinson, C Wright; Chari, Ravi S

    2004-01-01

    Radiofrequency ablation (RFA) is an evolving technology used to treat unresectable liver tumors. Currently, there is no accurate method to determine RFA margins in real-time during the procedure. We hypothesized that a fiber-optic based spectroscopic monitoring system could detect thermal damage from RFA in real-time. Fluorescence (F) and diffuse reflectance (Rd) spectra were continuously acquired from within the expected ablation zone during canine hepatic RFA using a fiber-optic microinterrogation probe (MIP). The F and Rd spectral feedback were continuously monitored and ablations were stopped based on changes in spectra alone. After each ablation, the MIP tract was marked with India ink and the ablation zone was excised. The relationship of the MIP to the zone of ablation was examined grossly and microscopically. F and Rd spectral changes occurred in three characteristic phases as the ablation zone progresses past the MIP. Phase 1 indicates minimal deviation from normal lives. Phase 2 occurs as the MIP lies within the hemorrhagic zone of the ablated tissue. Phase 3 correlates with complete tissue coagulation. The absolute magnitude of spectral change correlates with the gross and histologic degree of thermal damage. Optical spectroscopy is a technology that allows real-time detection of thermal tissue damage. In this study, both F and Rd spectroscopy accurately defined the advancing hemorrhagic edge of the zone of ablation and the central coagulation zone. These results suggest that F and Rd spectroscopy can be used to create a real-time feedback system to accurately define RFA margins. PMID:15358325

  19. Rat liver regeneration following ablation with irreversible electroporation

    PubMed Central

    Bruinsma, Bote G.; Jaramillo, Maria; Yarmush, Martin L.

    2016-01-01

    During the past decade, irreversible electroporation (IRE) ablation has emerged as a promising tool for the treatment of multiple diseases including hepatic cancer. However, the mechanisms behind the tissue regeneration following IRE ablation have not been investigated. Our results indicate that IRE treatment immediately kills the cells at the treatment site preserving the extracellular architecture, in effect causing in vivo decellularization. Over the course of 4 weeks, progenitor cell differentiation, through YAP and notch pathways, together with hepatocyte expansion led to almost complete regeneration of the ablated liver leading to the formation of hepatocyte like cells at the ablated zone. We did not observe significant scarring or tumor formation at the regenerated areas 6 months post IRE. Our study suggests a new model to study the regeneration of liver when the naïve extracellular matrix is decellularized in vivo with completely preserved extracellular architecture. PMID:26819842

  20. Tissue healing response following hyperthermic vapor ablation in the porcine longissimus muscle

    NASA Astrophysics Data System (ADS)

    Grantham, John T.; Grisez, Brian T.; Famoso, Justin; Hoey, Michael; Dixon, Chris; Coad, James E.

    2015-03-01

    As the use of hyperthermic ablation technologies has increased, so too has the need to understand their effects on tissue and their healing responses. This study was designed to characterize tissue injury and healing following hyperthermic vapor ablation in the in vivo porcine longissimus muscle model. The individual ablations were performed using the NxThera Vapor Delivery System (NxThera Inc., Minneapolis, MN). To assess the vapor ablation's evolution, the swine were euthanized post-treatment on Day 0, Day 3, Day 7, Day 14, Day 28, Day 45 and Day 90. Triphenyltetrazolium chloride viability staining (TTC staining) was used to macroscopically assess the extent of each vapor ablation within the tissue. The ablation associated healing responses were then histologically evaluated for acute inflammation, chronic inflammation, foreign body reaction and fibrosis. Two zones of tissue injury were initially identified in the ablations: 1) a central zone of complete coagulative necrosis and 2) an outer "transition zone" of viable and non-viable cells. The ablations initially increased in size from Day 0 to Day 7 and then progressively decreased in size though Day 45. The initial Day 3 healing changes originated in the transition zone with minimal acute and chronic inflammation. As time progressed, granulation tissue began to form by Day 7 and peaked around Day 14. Collagen formation, deposition and remodeling began in the adjacent healthy tissue by Day 28, replaced the ablation site by Day 45 and reorganized by Day 90. In conclusion, this vapor ablation technology provided a non-desiccating form of hyperthermic ablation that resulted in coagulative necrosis without a central thermally/heat-fixed tissue component, followed a classical wound healing pathway, and healed with minimal associated inflammation.

  1. Transient Ablation of Teflon Hemispheres

    NASA Technical Reports Server (NTRS)

    Arai, Norio; Karashima, Kei-ichi; Sato, Kiyoshi

    1997-01-01

    For high-speed entry of space vehicles into atmospheric environments, ablation is a practical method for alleviating severe aerodynamic heating. Several studies have been undertaken on steady or quasi-steady ablation. However, ablation is a very complicated phenomenon in which a nonequilibrium chemical process is associated with an aerodynamic process that involves changes in body shape with time. Therefore, it seems realistic to consider that ablation is an unsteady phenomenon. In the design of an ablative heat-shield system, since the ultimate purpose of the heat shield is to keep the internal temperature of the space vehicle at a safe level during entry, the transient heat conduction characteristics of the ablator may be critical in the selection of the material and its thickness. This note presents an experimental study of transient ablation of Teflon, with particular emphasis on the change in body shape, the instantaneous internal temperature distribution, and the effect of thermal expansion on ablation rate.

  2. Advanced Ablative TPS

    NASA Technical Reports Server (NTRS)

    Gasch, Matthew J.

    2011-01-01

    Early NASA missions (Gemini, Apollo, Mars Viking) employed new ablative TPS that were tailored for the entry environment. After 40 years, heritage ablative TPS materials using Viking or Pathfinder era materials are at or near their performance limits and will be inadequate for future exploration missions. Significant advances in TPS materials technology are needed in order to enable any subsequent human exploration missions beyond Low Earth Orbit. This poster summarizes some recent progress at NASA in developing families of advanced rigid/conformable and flexible ablators that could potentially be used for thermal protection in planetary entry missions. In particular the effort focuses technologies required to land heavy (approx.40 metric ton) masses on Mars to facilitate future exploration plans.

  3. Shuttle subscale ablative nozzle tests

    NASA Technical Reports Server (NTRS)

    Powers, L. B.; Bailey, R. L.

    1980-01-01

    Recent subscale nozzle tests have identified new and promising carbon phenolic nozzle ablatives which utilize staple rayon, PAN, and pitch based carbon cloth. A 4-inch throat diameter submerged test nozzle designed for the 48-inch Jet Propulsion Laboratory char motor was used to evaluate five different designs incorporating 20 candidate ablatives. Test results indicate that several pitch and PAN-based carbon phenolic ablatives can provide erosion and char performance equivalent or superior to the present continuous rayon-based SRM ablative.

  4. Conformal needle-based ultrasound ablation using EM-tracked conebeam CT image guidance

    NASA Astrophysics Data System (ADS)

    Burdette, E. Clif; Banovac, Filip; Diederich, Chris J.; Cheng, Patrick; Wilson, Emmanuel; Cleary, Kevin R.

    2011-03-01

    Numerous studies have demonstrated the efficacy of interstitial ablative approaches for the treatment of renal and hepatic tumors. Despite these promising results, current systems remain highly dependent on operator skill, and cannot treat many tumors because there is little control of the size and shape of the zone of necrosis, and no control over ablator trajectory within tissue once insertion has taken place. Additionally, tissue deformation and target motion make it extremely difficult to accurately place the ablator device into the target. Irregularly shaped target volumes typically require multiple insertions and several sequential thermal ablation procedures. This study demonstrated feasibility of spatially tracked image-guided conformal ultrasound (US) ablation for percutaneous directional ablation of diseased tissue. Tissue was prepared by suturing the liver within a pig belly and 1mm BBs placed to serve as needle targets. The image guided system used integrated electromagnetic tracking and cone-beam CT (CBCT) with conformable needlebased high-intensity US ablation in the interventional suite. Tomographic images from cone beam CT were transferred electronically to the image-guided tracking system (IGSTK). Paired-point registration was used to register the target specimen to CT images and enable navigation. Path planning is done by selecting the target BB on the GUI of the realtime tracking system and determining skin entry location until an optimal path is selected. Power was applied to create the desired ablation extent within 7-10 minutes at a thermal dose (>300eqm43). The system was successfully used to place the US ablator in planned target locations within ex-vivo kidney and liver through percutaneous access. Targeting accuracy was 3-4 mm. Sectioned specimens demonstrated uniform ablation within the planned target zone. Subsequent experiments were conducted for multiple ablator positions based upon treatment planning simulations. Ablation zones in

  5. Thermal ablation in cancer

    PubMed Central

    Liu, Yong; Cao, Cheng-Song; Yu, Yang; Si, Ya-Meng

    2016-01-01

    Radiofrequency ablation (RFA) and cryoablation are alternative forms of therapy used widely in various pathological states, including treatment of carcinogenesis. The reason is that ablation techniques have ability of modulating the immune system. Furthermore, recent studies have applied this form of therapy on tumor microenvironment and in the systematic circulation. Moreover, RFA and cryoablation result in an inflammatory immune response along with tissue disruption. Evidence has demonstrated that these procedures affect carcinogenesis by causing a significant local inflammatory response leading to an immunogenic gene signature. The present review enlightens the current view of these techniques in cancer. PMID:27703520

  6. Laser ablation studies in southern Africa

    NASA Astrophysics Data System (ADS)

    McKenzie, Edric; Forbes, A.; Turner, G. R.; Michaelis, Max M.

    2000-08-01

    With the launch of the South African National Laser Centre, new programs will need to be defined. Medical, environmental and industrial laser applications must obviously take top priority -- as opposed to the uranium isotope separation and military applications of the past. We argue however, that a small effort in laser ablation for space propulsion is justifiable, since a few very large CO2 lasers are available and since two tentative propulsion experiments have already been conducted in South Africa. We attempt to give LISP (Laser Impulse Space Propulsion) an equatorial and a Southern dimension.

  7. Microwave ablation energy delivery: Influence of power pulsing on ablation results in an ex vivo and in vivo liver model

    PubMed Central

    Bedoya, Mariajose; del Rio, Alejandro Muñoz; Chiang, Jason; Brace, Christopher L.

    2014-01-01

    pulsed ablations were again slightly more circular. Conclusions: Pulsed energy delivery created larger ablation zones at low average power compared to continuous energy delivery in the presence of blood perfusion. Shorter duty cycles appear to provide greater benefit when pulsing. PMID:25471983

  8. Solid state ultraviolet laser (213 nm) ablation of the cornea and synthetic collagen lenticules.

    PubMed

    Gailitis, R P; Ren, Q S; Thompson, K P; Lin, J T; Waring, G O

    1991-01-01

    We used a Q-switched Nd:YAG laser with non-linear optical crystals to produce the 5th (213 nm) and the 4th (266 nm) harmonic frequencies. Using these two wavelengths, we ablated fresh porcine corneas and type I collagen synthetic epikeratoplasty lenticules. For the 213-nm ablation, radiant exposure was 1.3 J/cm2. The ablation rate was 0.23 micron per pulse for the epikeratoplasty lenticules. We examined all tissues with light microscopy, transmission electron microscopy, and scanning electron microscopy. Histology for the 213-nm ablation showed a clean ablation crater with minimal collagen lamellae disruption and a damage zone less than 1 micron. In comparison, the 266 nm radiation showed more charring at the edges with a damage zone approximately 25 microns deep with disruption of the stromal lamella. Our results show that this solid state UV laser is a potential alternative to the excimer laser for cornea surgery.

  9. Heating characteristics of antenna arrays used in microwave ablation: A theoretical parametric study.

    PubMed

    Karampatzakis, Andreas; Kühn, Sven; Tsanidis, George; Neufeld, Esra; Samaras, Theodoros; Kuster, Niels

    2013-10-01

    A numerical study of the performance of antenna arrays used in microwave ablation (MWA) is carried out. Double-slot coaxial antennas in triangular and square configurations are studied. Clinical (healthy vs. malignant) and experimental (in vs. ex vivo) scenarios for hepatic cancer treatment are modeled, and further application in bone and lung tissue is examined. It is found that triangular arrays can create spherical ablation zones, while square configurations result in flatter ones. Thresholds in power and application times for creating continuous ablation zones are calculated, and the characteristics of the latter are quantified. PMID:24034722

  10. Printable Nanophotonic Devices via Holographic Laser Ablation.

    PubMed

    Zhao, Qiancheng; Yetisen, Ali K; Sabouri, Aydin; Yun, Seok Hyun; Butt, Haider

    2015-09-22

    Holography plays a significant role in applications such as data storage, light trapping, security, and biosensors. However, conventional fabrication methods remain time-consuming, costly, and complex, limiting the fabrication of holograms and their extensive use. Here, we demonstrate a single-pulse laser ablation technique to write parallel surface gratings and Fresnel zone plates. We utilized a 6 ns high-energy green laser pulse to form interference patterns to record a surface grating with 820 nm periodicity and asymmetric zone plate holograms on 4.5 nm gold-coated substrates. The holographic recording process was completed within seconds. The optical characteristics of the interference patterns have been computationally modeled, and well-ordered polychromatic diffraction was observed from the fabricated holograms. The zone plate showed a significant diffraction angle of 32° from the normal incident for the focal point. The nanosecond laser interference ablation for rapid hologram fabrication holds great potential in a vast range of optical devices. PMID:26301907

  11. Towards Fully Diagnosed Ablative Rayleigh-Taylor Instability

    NASA Astrophysics Data System (ADS)

    Azechi, Hiroshi

    2002-11-01

    The Rayleigh-Taylor (RT) instability with material ablation through the unstable interface is the key physics that determines the success or failure of inertial fusion energy. The ablative RT instability has also general resemblance to hydrodynamic instabilities occurring in Type Ia supernovae and in interstellar clouds, such as the Eagle Nebula. In the laser fusion community, it is generally accepted that the Bodner-Takabe formula [1] with significant improvement by Betti [2] may predict correct dispersion relation of the growth rates of the ablative RT instability. However, there still exist theoretical uncertainties due to the different treatment of electron transport from the laser absorption region to the ablation region. The difference in the electron transport is most pronounced at short wavelength perturbation that is below spatial resolution of most x-ray imagers. The direct effect of the transport is the ablation density profile, which measurement is also a formidable task with conventional diagnostic techniques. We will present our RT growth as well as the ablation density measurements based on recently developed novel techniques of high spatial resolution: moir interferometry, penumbral imaging, and Fresnel-phase-zone-plate imaging. [1] S. Bodner, Phys. Rev. Lett. 33, 761 (1974); H. Takabe et al., Phys. Fluids 28, 3676 (1985). [2] R. Betti et al., Phys. Plasmas 5, 1446 (1998).

  12. Spatiotemporal electrophysiological changes in a murine ablation model

    PubMed Central

    Bernstein, Scott A.; Duggirala, Srikant; Floberg, Michael; Elfvendal, Pehr; Kuznekoff, Laura M.; Lader, Joshua M.; Vasquez, Carolina; Morley, Gregory E.

    2011-01-01

    Aims High recurrence rates after complex radiofrequency ablation procedures, such as for atrial fibrillation, remain a major clinical problem. Local electrophysiological changes that occur following cardiac ablation therapy are incompletely described in the literature. The purpose of this study was to determine whether alterations in conduction velocity, action potential duration (APD), and effective refractory period resolve dynamically following cardiac ablation. Methods and results  Lesions were delivered to the right ventricle of mice using a subxiphoid approach. The sham-operated control group (SHAM) received the same procedure without energy delivery. Hearts were isolated at 0, 1, 7, 30, and 60 days following the procedure and electrophysiological parameters were obtained using high-resolution optical mapping with a voltage-sensitive dye. Conduction velocity was significantly decreased at the lesion border in the 0, 7, and 30 day groups compared to SHAM. APD70 at the lesion border was significantly increased at all time points compared to SHAM. Effective refractory period was significantly increased at the lesion border at 0, 1, 7, and 30 days but not at 60 days post-ablation. This study demonstrated that post-ablation electrophysiological changes take place immediately following energy delivery and resolve within 60 days. Conclusions Cardiac ablation causes significant electrophysiological changes both within the lesion and beyond the border zone. Late recovery of electrical conduction in individual lesions is consistent with clinical data demonstrating that arrhythmia recurrence is associated with failure to maintain bi-directional conduction block. PMID:21712278

  13. Investigation of ultrashort pulse laser ablation of solid targets by measuring the ablation-generated momentum using a torsion pendulum.

    PubMed

    Zhang, Nan; Wang, Wentao; Zhu, Xiaonong; Liu, Jiansheng; Xu, Kuanhong; Huang, Peng; Zhao, Jiefeng; Li, Ruxin; Wang, Mingwei

    2011-04-25

    50 fs - 12 ps laser pulses are employed to ablate aluminum, copper, iron, and graphite targets. The ablation-generated momentum is measured with a torsion pendulum. Corresponding time-resolved shadowgraphic measurements show that the ablation process at the optimal laser fluence achieving the maximal momentum is primarily dominated by the photomechanical mechanism. When laser pulses with specific laser fluence are used and the pulse duration is tuned from 50 fs to 12 ps, the generated momentum firstly increases and then remains almost constant, which could be attributed to the change of the ablation mechanism involved from atomization to phase explosion. The investigation of the ablation-generated momentum also reveals a nonlinear momentum-energy conversion scaling law, namely, as the pulse energy increases, the momentum obtained by the target increases nonlinearly. This may be caused by the effective reduction of the dissipated energy into the surrounding of the ablation zone as the pulse energy increases, which indicates that for femtosecond laser the dissipated energy into the surrounding target is still significant.

  14. Ablation of Martian glaciers

    NASA Technical Reports Server (NTRS)

    Moore, Henry J.; Davis, Philip A.

    1987-01-01

    Glacier like landforms are observed in the fretted terrain of Mars in the latitude belts near + or - 42 deg. It was suggested that sublimation or accumulation-ablation rates could be estimated for these glaciers if their shapes were known. To this end, photoclinometric profiles were obtained of a number of these landforms. On the basis of analyses of these profiles, it was concluded that ice is chiefly ablating from these landforms that either are inactive rock-glaciers or have materials within them that are moving exceedingly slowly at this time. These conclusions are consistent with other geologic information. The analyses were performed using a two-dimensional model of an isothermal glacier.

  15. OCDR guided laser ablation device

    DOEpatents

    Dasilva, Luiz B.; Colston, Jr., Bill W.; James, Dale L.

    2002-01-01

    A guided laser ablation device. The device includes a mulitmode laser ablation fiber that is surrounded by one or more single mode optical fibers that are used to image in the vicinity of the laser ablation area to prevent tissue damage. The laser ablation device is combined with an optical coherence domain reflectometry (OCDR) unit and with a control unit which initializes the OCDR unit and a high power laser of the ablation device. Data from the OCDR unit is analyzed by the control unit and used to control the high power laser. The OCDR images up to about 3 mm ahead of the ablation surface to enable a user to see sensitive tissue such as a nerve or artery before damaging it by the laser.

  16. Multiple target laser ablation system

    DOEpatents

    Mashburn, Douglas N.

    1996-01-01

    A laser ablation apparatus and method are provided in which multiple targets consisting of material to be ablated are mounted on a movable support. The material transfer rate is determined for each target material, and these rates are stored in a controller. A position detector determines which target material is in a position to be ablated, and then the controller controls the beam trigger timing and energy level to achieve a desired proportion of each constituent material in the resulting film.

  17. Multiple target laser ablation system

    DOEpatents

    Mashburn, D.N.

    1996-01-09

    A laser ablation apparatus and method are provided in which multiple targets consisting of material to be ablated are mounted on a movable support. The material transfer rate is determined for each target material, and these rates are stored in a controller. A position detector determines which target material is in a position to be ablated, and then the controller controls the beam trigger timing and energy level to achieve a desired proportion of each constituent material in the resulting film. 3 figs.

  18. Role of debris cover to control specific ablation of adjoining Batal and Sutri Dhaka glaciers in Chandra Basin (Himachal Pradesh) during peak ablation season

    NASA Astrophysics Data System (ADS)

    Sharma, Parmanand; Patel, Lavkush K.; Ravindra, Rasik; Singh, Ajit; K, Mahalinganathan; Thamban, Meloth

    2016-04-01

    As part of the on-going annual mass balance measurements on Batal and Sutri Dhaka glaciers, observations were made during peak ablation (August-September) season in 2013 to understand the response of debris covered and clean-ice (debris free) glacier surface to melting processes. Though, both the Batal and Sutri Dhaka glaciers have almost similar geographical disposition, Batal shows extensive debris cover (90% of the ablation area), while the latter is free from debris (only 5% of the ablation area). The thickness of debris in Batal glacier is inversely proportional to altitude, whereas Sutri Dhaka mostly experienced debris-free zone except snout area. Observation revealed that the vertical gradient of ablation rate in ablation area is contrastingly opposite in these two glaciers, reflecting significant control of debris thickness and their distribution over glacier surface on the ablation rates. While different thickness (2-100 cm) of debris have attenuated melting rates up to 70% of total melting, debris cover of <2 cm thickness has accelerated melting up to 10% of the total melting. Estimated melt ratio reveals that about 90% of the ablation area has experienced inhibited melting in Batal glacier, whereas only less than 5% ablation area of Sutri Dhaka has undergone inhibited melting. Comparison of topographical maps of 1962 with successive satellite images of the area demonstrates a terminus retreat of 373 ± 33.5 m and 579 ± 33.5 m for Batal and Sutri Dhaka glaciers for the period 1962-2013, respectively.

  19. Practical Laser Ablation U-Th Thermochronology and Geochronology

    NASA Astrophysics Data System (ADS)

    Hodges, K.; Van Soest, M. C.; Tripathy, A.; Boyce, J. W.

    2012-12-01

    (U-Th)/He thermochronology of the accessory phases apatite and zircon has become an essential tool for many landscape evolution and tectonic studies. Moreover, new geochronologic applications of the (U-Th)/He method -dating impact events, young volcanic eruptions, and secondary hydrothermal mineralization, for example - are only recently being explored. A significant impediment to all applications of the method is a commonly observed scatter of replicate dates for different crystals from an individual sample, typically greater than that which can be explained by analytical imprecision alone. While several reasons for this have been proposed, three are certainly important: 1) the propensity for many accessory minerals to be strongly and complexly zoned in U and Th; 2) inclusions of other (U+Th)-rich minerals in dated grains; and 3) frequently ignored and generally unquantifiable uncertainties in the alpha ejection corrections applied to dated crystals. For nearly a decade, we have worked to establish a new technique that avoids or minimizes the impact of these factors. Individual crystals are mounted, polished, and imaged to resolve internal zonation and inclusion content as a means of selecting appropriate grains for analysis. A 193 nm ArF excimer laser is used to ablate sample from the center of the polished surface, sufficiently far from the crystal rim to eliminate the need for an alpha ejection correction. 4He is measured in the ablated material by magnetic sector, gas-source mass spectrometry. After precise measurement of the ablation pit to permit the determination of 4He concentration, the sample is removed and mounted for U + Th analysis by laser ablation inductively coupled, plasma mass spectrometry. For parent element analyses, the ablation pit is targeted so as to encompass the 4He ablation pit on a scale large enough to integrate intragranular U + Th zoning and account for recoil redistribution of 4He within grains. We have documented the efficacy of

  20. Radiofrequency Ablation with a New Perfused-Cooled Electrode Using a Single Pump: An Experimental Study in Ex Vivo Bovine Liver

    SciTech Connect

    Kim, Seung Kwon Seo, Jung Wook

    2005-12-15

    The purpose of this study was to assess the efficacy of a new perfused-cooled electrode that uses a single pump for creating a large ablation zone in explanted bovine liver. This was done by comparing with the radiofrequency (RF) ablation zones that were created with a monopolar cooled electrode to the RF ablation zones that were created by the new perfused-cooled electrode. We developed a new perfused-cooled electrode that uses a single pump by modifying a 17-gauge cooled electrode (Radionics) with a 2.5-cm outer metallic sheath (15-gauge) in order to allow use of the internal cooling water (5.85 % hypertonic saline) for the infused saline. Thirty ablation zones were created in explanted bovine livers (12-min ablation cycle; pulsed technique; 2000 mA, maximum) with three different regimens: group A, RF ablation with the 17-gauge cooled electrode; group B, RF ablation with the 15-gauge cooled electrode; group C, RF ablation with the perfused-cooled electrode. T2-weighted magnetic resonance (MR) imaging was obtained immediately after RF ablation for calculating volumes of the ablation zone. Following MR imaging, the ablation zones were excised and measured for transverse diameters and vertical diameters. The transverse diameter, vertical diameter, and the calculated volumes of the ablation zones on MR imaging were compared among the groups. Ablation zones created with the perfused-cooled electrode (group C) were significantly larger than those created with the 17-gauge cooled electrode (group A) and the 15-gauge cooled electrode (group B) according to the transverse diameter and vertical diameter on the gross specimens (p < 0.05): 3.6 {+-} 0.38 cm and 4.4 {+-} 0.20 cm in group A, 3.7 {+-} 0.08 cm and 4.6 {+-} 0.16 cm in group B, and 5.4 {+-} 0.65 cm and 6.0 {+-} 0.56 cm in group C, respectively. On the MR imaging, the calculated volumes of the ablation zones in group C were significantly larger than those in groups A and B (p < 0.05): 23.1 {+-} 8.7 cm{sup 3} in

  1. Matricectomy and nail ablation.

    PubMed

    Baran, Robert; Haneke, Eckart

    2002-11-01

    Matricectomy refers to the complete extirpation of the nail matrix, resulting in permanent nail loss. Usually however, matricectomy is only partial, restricted to one or both lateral horns of the matrix. Nail ablation is the definitive removal of the entire nail organ. The most important common denominator in the successful matricectomy is the total removal or destruction of the matrix tissue. Matricectomy may be indicated for the management of onychauxis, onychogryphosis, congenital nail dystrophies, and chronic painful nail, such as recalcitrant ingrown toenail or split within the medial or lateral one-third of the nail.

  2. High temperature ablative foam

    NASA Technical Reports Server (NTRS)

    Liu, Matthew T. (Inventor)

    1992-01-01

    An ablative foam composition is formed of approximately 150 to 250 parts by weight polymeric isocyanate having an isocyanate functionality of 2.6 to 3.2; approximately 15 to 30 parts by weight reactive flame retardant having a hydroxyl number range from 200-260; approximately 10 to 40 parts by weight non-reactive flame retardant; approximately 10 to 40 parts by weight nonhydrolyzable silicone copolymer having a hydroxyl number range from 75-205; and approximately 3 to 16 parts by weight amine initiated polyether resin having an isocyanate functionality greater than or equal to 3.0 and a hydroxyl number range from 400-800.

  3. Percutaneous Ablation in the Kidney

    PubMed Central

    Wood, Bradford J.; Gervais, Debra A.

    2011-01-01

    Percutaneous ablation in the kidney is now performed as a standard therapeutic nephron-sparing option in patients who are poor candidates for resection. Its increasing use has been largely prompted by the rising incidental detection of renal cell carcinomas with cross-sectional imaging and the need to preserve renal function in patients with comorbid conditions, multiple renal cell carcinomas, and/or heritable renal cancer syndromes. Clinical studies to date indicate that radiofrequency ablation and cryoablation are effective therapies with acceptable short- to intermediate-term outcomes and with a low risk in the appropriate setting, with attention to pre-, peri-, and postprocedural detail. The results following percutaneous radiofrequency ablation and cryoablation in the treatment of renal cell carcinoma are reviewed in this article, including those of several larger scale studies of ablation of T1a tumors. Clinical and technical considerations unique to ablation in the kidney are presented, and potential complications are discussed. © RSNA, 2011 PMID:22012904

  4. The Importance of Ablation on ice Flow and Meteorite Exhumation: the Physical Modeling Approach at Frontier Mountain, Antarctica

    NASA Astrophysics Data System (ADS)

    Zeoli, A.; Folco, L.; Corti, G.

    2008-12-01

    The highest concentration of meteorites yet discovered on Earth is found in the ice sheet covering Antarctica. Major meteorite accumulation zones often occur in front of submerged or emerged bedrock obstacles, where the meteorite-bearing ice slows down, is uplifted by the buttressing effect and exhumed and concentrated by wind ablation ("ice-flow model"). Meteorite traps have also been discovered in the downstream side of major emerged bedrock barriers, as in the Frontier Mountain (FM) region, a nunatak outcropping in the Northern Victoria Land, Antarctica, 250 km from the Italian Terra Nova Base. However, recent detailed glaciological analyses indicate that also for this site the "ice-flow model" remains the best concentration explanation, being present an important submerged barrier in the main blue-ice field. A this site, during the last fifteen years, more than 1000 meteorites have been there collected. During the various field expeditions, different data were acquired to allow a detailed study of the local glaciodynamics. This large data set was used to constrain boundary conditions for performing a set of physical experiments reproducing the main glaciodynamics characteristics of the FM region. In addition to previous result, now we performed a series of experiments that consider also the ablation effect in order to better reproduce the natural environment. Analog experiments were performed at the Tectonic Modelling Laboratory of the CNR-IGG (Florence, Italy). Polydimethilsyloxane (PDMS) is used to simulate glacial flow in analog models; this material properly simulates the rheological behaviour of ice (Corti et al, 2003; Corti et al, 2008). Models are built inside a Plexiglas box with dimensions of 70cm x 20cm x 10cm. The models are scaled to nature conditions allowing a comparison between laboratories and natural models. The geometrical scaling ratio was of 2*10-5, such that 1 cm in the model represented about 500 m in nature. In order to measure the

  5. Planning Irreversible Electroporation in the Porcine Kidney: Are Numerical Simulations Reliable for Predicting Empiric Ablation Outcomes?

    SciTech Connect

    Wimmer, Thomas Srimathveeravalli, Govindarajan; Gutta, Narendra; Ezell, Paula C.; Monette, Sebastien; Maybody, Majid; Erinjery, Joseph P.; Durack, Jeremy C.; Coleman, Jonathan A.; Solomon, Stephen B.

    2015-02-15

    PurposeNumerical simulations are used for treatment planning in clinical applications of irreversible electroporation (IRE) to determine ablation size and shape. To assess the reliability of simulations for treatment planning, we compared simulation results with empiric outcomes of renal IRE using computed tomography (CT) and histology in an animal model.MethodsThe ablation size and shape for six different IRE parameter sets (70–90 pulses, 2,000–2,700 V, 70–100 µs) for monopolar and bipolar electrodes was simulated using a numerical model. Employing these treatment parameters, 35 CT-guided IRE ablations were created in both kidneys of six pigs and followed up with CT immediately and after 24 h. Histopathology was analyzed from postablation day 1.ResultsAblation zones on CT measured 81 ± 18 % (day 0, p ≤ 0.05) and 115 ± 18 % (day 1, p ≤ 0.09) of the simulated size for monopolar electrodes, and 190 ± 33 % (day 0, p ≤ 0.001) and 234 ± 12 % (day 1, p ≤ 0.0001) for bipolar electrodes. Histopathology indicated smaller ablation zones than simulated (71 ± 41 %, p ≤ 0.047) and measured on CT (47 ± 16 %, p ≤ 0.005) with complete ablation of kidney parenchyma within the central zone and incomplete ablation in the periphery.ConclusionBoth numerical simulations for planning renal IRE and CT measurements may overestimate the size of ablation compared to histology, and ablation effects may be incomplete in the periphery.

  6. Thermal response and ablation characteristics of light weight ceramic ablators

    NASA Technical Reports Server (NTRS)

    Tran, Huy K.; Rasky, Daniel J.; Esfahani, Lili

    1993-01-01

    An account is given of the thermal performance and ablation characteristics of the NASA-Ames Lightweight Ceramic Ablators (LCAs) in supersonic, high-enthalpy convective environments, which use low density ceramic or carbon fiber matrices as substrates for main structural support, with organic resin fillers. LCA densities are in the 0.224-1.282 g/cu cm range. In-depth temperature data have been obtained to determine thermal penetration depths and conductivity. The addition of SiC and PPMA is noted to significantly improve the ablation performance of LCAs with silica substrates. Carbon-based LCAs are the most mass-efficient at high flux levels.

  7. Percutaneous microwave ablation vs radiofrequency ablation in the treatment of hepatocellular carcinoma

    PubMed Central

    Poulou, Loukia S; Botsa, Evanthia; Thanou, Ioanna; Ziakas, Panayiotis D; Thanos, Loukas

    2015-01-01

    Hepatocellular cancer ranks fifth among cancers and is related to chronic viral hepatitis, alcohol abuse, steatohepatitis and liver autoimmunity. Surgical resection and orthotopic liver transplantation have curative potential, but fewer than 20% of patients are suitable candidates. Interventional treatments are offered to the vast majority of patients. Radiofrequency (RFA) and microwave ablation (MWA) are among the therapeutic modalities, with similar indications which include the presence of up to three lesions, smaller than 3 cm in size, and the absence of extrahepatic disease. The therapeutic effect of both methods relies on thermal injury, but MWA uses an electromagnetic field as opposed to electrical current used in RFA. Unlike MWA, the effect of RFA is partially limited by the heat-sink effect and increased impedance of the ablated tissue. Compared with RFA, MWA attains a more predictable ablation zone, permits simultaneous treatment of multiple lesions, and achieves larger coagulation volumes in a shorter procedural time. Major complications of both methods are comparable and infrequent (approximately 2%-3%), and they include haemorrhage, infection/abscess, visceral organ injury, liver failure, and pneumothorax. RFA may incur the additional complication of skin burns. Nevertheless, there is no compelling evidence for differences in clinical outcomes, including local recurrence rates and survival. PMID:26052394

  8. Laser Ablation of Polymer Microfluidic Devices

    NASA Astrophysics Data System (ADS)

    Killeen, Kevin

    2004-03-01

    Microfluidic technology is ideal for processing precious samples of limited volumes. Some of the most important classes of biological samples are both high in sample complexity and low in concentration. Combining the elements of sample pre-concentration, chemical separation and high sensitivity detection with chemical identification is essential for realizing a functional microfluidic based analysis system. Direct write UV laser ablation has been used to rapidly fabricate microfluidic devices capable of high performance liquid chromatography (HPLC)-MS. These chip-LC/MS devices use bio-compatible, solvent resistant and flexible polymer materials such as polyimide. A novel microfluidic to rotary valve interface enables, leak free, high pressure fluid switching between multiple ports of the microfluidic chip-LC/MS device. Electrospray tips with outer dimension of 50 um and inner of 15 um are formed by ablating the polymer material concentrically around a multilayer laminated channel structure. Biological samples of digested proteins were used to evaluate the performance of these microfluidic devices. Liquid chromatography separation and similar sample pretreatments have been performed using polymeric microfluidic devices with on-chip separation channels. Mass spectrometry was performed using an Agilent Technologies 1100 series ion trap mass spectrometer. Low fmol amounts of protein samples were positively and routinely identified by searching the MS/MS spectral data against protein databases. The sensitivity and separation performance of the chip-LC devices has been found to be comparable to state of the art nano-electrospray systems.

  9. Epicardial Ablation of Ventricular Tachycardia

    PubMed Central

    Tung, Roderick; Shivkumar, Kalyanam

    2015-01-01

    Epicardial mapping and ablation via a percutaneous subxiphoid technique has been instrumental in improving the working understanding of complex myocardial scars in various arrhythmogenic substrates. Endocardial ablation alone may not be sufficient in patients with ischemic cardiomyopathy, dilated cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy, hypertrophic cardiomyopathy, and Chagas disease to prevent recurrent ventricular tachycardia. Multiple observational studies have demonstrated greater freedom from recurrence with adjunctive epicardial ablation compared with endocardial ablation alone. While epicardial ablation is performed predominantly at tertiary referral centers, knowledge of the technical approach, clinical indications, and potential complications is imperative to maximizing clinical success and patient safety. In 1996, Sosa and colleagues modified the pericardiocentesis technique to enable percutaneous access to the pericardial space for mapping and catheter ablation of ventricular tachycardia.1 Originally developed for patients with epicardial scarring due to chagasic cardiomyopathy and patients with ischemic cardiomyopathy refractory to endocardial ablationm,2,3 this approach has since become an essential part of the armamentarium for the treatment of ventricular tachycardia. Myocardial scars are three-dimensionally complex with varying degrees of transmurality, and the ability to map and ablate the epicardial surface has contributed to a greater understanding of scar-related VT in postinfarction cardiomyopathy and nonischemic substrates including idiopathic dilated cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy, hypertrophic cardiomyopathy, and chagasic cardiomyopathy. In this review, we highlight the percutaneous approach and discuss clinical indications and potential complications. PMID:26306131

  10. Ex Vivo Experiment of Saline-Enhanced Hepatic Bipolar Radiofrequency Ablation with a Perfused Needle Electrode: Comparison with Conventional Monopolar and Simultaneous Monopolar Modes

    SciTech Connect

    Lee, Jeong Min Kim, Se Hyung; Han, Joon Koo; Sohn, Kyu Li; Choi, Byung Ihn

    2005-04-15

    The purpose of this study was to validate the saline-enhanced bipolar radiofrequency ablation (RFA) technique using a perfused electrode to increase RF-created coagulation necrosis, to compare that technique with monopolar RFAs and to find appropriate concentrations and volumes of perfused NaCl solution for the bipolar RFA. A total of 90 ablations were performed in explanted bovine livers. In the initial experiments to determine appropriate conditions for bipolar RFA, we created five thermal ablation zones in each condition, with instillations of varied concentrations (0.9-36%) or injection rates (30 mL/hr-120 mL/hr) of NaCl solution. After placement of one or two 16-gauge open-perfused electrodes into bovine livers, the NaCl solution was instilled into the tissue through the electrode. In the second part of the study, 10 ablation zones were created using one or two perfused electrodes for each of five groups under different conditions: a conventional monopolar mode with 0.9% NaCl solution (group A) or with 6% NaCl solution (group B), a simultaneous monopolar mode with 6% NaCl solution (group C) and a bipolar mode with 6% NaCl solution (groups D and E). RF was applied to each electrode for 20 min in groups A, B, C, and E, or for 10 min in group D. During RFA, we measured the tissue temperature 15 mm from the electrode. The temperature changes during the RFA and the dimensions of the ablation zones were compared among the groups. Bipolar RFA created larger short-axis diameters of coagulation necrosis with 6% NaCl solution (35.8 {+-} 15 mm) than with 0.9% NaCl solution (17 {+-} 9.7 mm) (P < 0.05). However, concentrations of NaCl solution above 6% did not further increase the extent of coagulation necrosis. In addition, bipolar RFA with 6% NaCl solution instillation at a rate of 1.0 mL/min (37.9 {+-} 5.4 mm) or 2.0 mL/min (35.6 {+-} 9.3 mm) produced larger diameters at the mid-point between the electrodes of the ablated lesion than did 0.5 mL/min (25.8 {+-} 9.3 mm) (P

  11. [New techniques of tumor ablation (microwaves, electroporation)].

    PubMed

    de Baere, T

    2011-09-01

    Since the introduction of radiofrequency tumor ablation of liver tumors in the late 1990s, local destructive therapies have been applied to lung, renal and bone lesions. In addition, new techniques have been introduced to compensate for the limitations of radiofrequency ablation, namely the reduced rate of complete ablation for tumors larger than 3 cm and tumors near vessels larger than 3 mm. Microwave ablation is currently evolving rapidly. While it is a technique based on thermal ablation similar to radiofrequency ablation, there are significant differences between both techniques. Electroporation, of interest because of the non-thermal nature of the ablation process, also is under evaluation.

  12. Ion acceleration enhanced by target ablation

    SciTech Connect

    Zhao, S.; Lin, C. Wang, H. Y.; Lu, H. Y.; He, X. T.; Yan, X. Q.; Chen, J. E.; Cowan, T. E.

    2015-07-15

    Laser proton acceleration can be enhanced by using target ablation, due to the energetic electrons generated in the ablation preplasma. When the ablation pulse matches main pulse, the enhancement gets optimized because the electrons' energy density is highest. A scaling law between the ablation pulse and main pulse is confirmed by the simulation, showing that for given CPA pulse and target, proton energy improvement can be achieved several times by adjusting the target ablation.

  13. Real-time calibration of temperature estimates during radiofrequency ablation.

    PubMed

    Varghese, T; Daniels, M J

    2004-07-01

    Radiofrequency ablation is an interstitial focal ablative therapy that can be used in a percutaneous fashion and permits in situ destruction of hepatic tumors. Recurrence rates after rf therapy are as high as 34-55%, due to difficulties in accurately identifying the zone of necrosis (thermal lesion) because of the low intrinsic acoustic contrast between normal and ablated liver tissue. Our goal is to provide real-time ultrasonic tracking of temperature changes over the large range of temperatures traditionally used (40-100 degrees C) in rfablation procedures using an external ultrasound transducer. Temperature estimates are obtained using a cross-correlation algorithm applied to rf ultrasound echo signal data acquired at discrete intervals during heating. Apparent tissue displacement estimates obtained at these discrete time-intervals are accumulated to obtain a cumulative displacement map, whose gradient provides after appropriate scaling provides a temperature map at the specified elapsed ablation duration. Temperature maps are used to display the initial temperature rise and to continuously update a thermal map of the treated region. In this paper, we develop calibration curves that relate the echo shift due to the change in the speed of sound and thermal expansion to the corresponding temperature increase on in-vitro tissue specimens. These calibration curves can then be utilized for the real time calibration and analysis of temperature estimates obtained from the rf echo signals during ablation. Temperature maps obtained using the calibration curve compare favorably to temperature estimates observed using the invasive thermosensor readings on the ablation electrode and previous results that utilized a linear calibration factor.

  14. Dynamics of tissue shrinkage during ablative temperature exposures

    PubMed Central

    Rossmann, Christian; Garrett-Mayer, Elizabeth; Rattay, Frank; Haemmerich, Dieter

    2014-01-01

    There is a lack of studies that examine dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occurs due to protein denaturation, dehydration, and contraction of collagen at temperatures greater 50ºC. This is particularly relevant for image-guided procedures such as tumor ablation, where pre- and post-treatment images are compared and any changes in dimensions must be considered to avoid misinterpretations of the treatment outcome. We present data from ex vivo, isothermal shrinkage tests in porcine liver tissue, where axial changes in tissue length were recorded during 15 minutes of heating to temperatures between 60 and 95ºC. A mathematical model was developed to accurately describe the time and temperature-dependent shrinkage behavior. Shrinkage dynamics had same characteristics independent of temperature; the estimated relative shrinkage, adjusted for time since death, after 15 min heating to temperatures of 60, 65, 75, 85 and 95ºC, was 12.3, 13.8, 16.6, 19.2, and 21.7%, respectively. Our results demonstrate shrinkage dynamics of organ tissues, and suggest the importance of considering tissue shrinkage for thermal ablative treatments. PMID:24345880

  15. Ablative Approaches for Pulmonary Metastases.

    PubMed

    Boyer, Matthew J; Ricardi, Umberto; Ball, David; Salama, Joseph K

    2016-02-01

    Pulmonary metastases are common in patients with cancer for which surgery is considered a standard approach in appropriately selected patients. A number of patients are not candidates for surgery due to a medical comorbidities or the extent of surgery required. For these patients, noninvasive or minimally invasive approaches to ablate pulmonary metastases are potential treatment strategies. This article summarizes the rationale and outcomes for non-surgical treatment approaches, including radiotherapy, radiofrequency and microwave ablation, for pulmonary metastases.

  16. Laser ablation in analytical chemistry.

    PubMed

    Russo, Richard E; Mao, Xianglei; Gonzalez, Jhanis J; Zorba, Vassilia; Yoo, Jong

    2013-07-01

    In 2002, we wrote an Analytical Chemistry feature article describing the Physics of Laser Ablation in Microchemical Analysis. In line with the theme of the 2002 article, this manuscript discusses current issues in fundamental research, applications based on detecting photons at the ablation site (LIBS and LAMIS) and by collecting particles for excitation in a secondary source (ICP), and directions for the technology. PMID:23614661

  17. Evaluation of a Thermoprotective Gel for Hydrodissection During Percutaneous Microwave Ablation: In Vivo Results

    SciTech Connect

    Moreland, Anna J. Lubner, Meghan G. Ziemlewicz, Timothy J. Kitchin, Douglas R. Hinshaw, J. Louis Johnson, Alexander D. Lee, Fred T. Brace, Christopher L.

    2015-06-15

    PurposeTo evaluate whether thermoreversible poloxamer 407 15.4 % in water (P407) can protect non-target tissues adjacent to microwave (MW) ablation zones in a porcine model.Materials and MethodsMW ablation antennas were placed percutaneously into peripheral liver, spleen, or kidney (target tissues) under US and CT guidance in five swine such that the expected ablation zones would extend into adjacent diaphragm, body wall, or bowel (non-target tissues). For experimental ablations, P407 (a hydrogel that transitions from liquid at room temperature to semi-solid at body temperature) was injected into the potential space between target and non-target tissues, and the presence of a gel barrier was verified on CT. No barrier was used for controls. MW ablation was performed at 65 W for 5 min. Thermal damage to target and non-target tissues was evaluated at dissection.ResultsAntennas were placed 7 ± 3 mm from the organ surface for both control and gel-protected ablations (p = 0.95). The volume of gel deployed was 49 ± 27 mL, resulting in a barrier thickness of 0.8 ± 0.5 cm. Ablations extended into non-target tissues in 12/14 control ablations (mean surface area = 3.8 cm{sup 2}) but only 4/14 gel-protected ablations (mean surface area = 0.2 cm{sup 2}; p = 0.0005). The gel barrier remained stable at the injection site throughout power delivery.ConclusionWhen used as a hydrodissection material, P407 protected non-targeted tissues and was successfully maintained at the injection site for the duration of power application. Continued investigations to aid clinical translation appear warranted.

  18. In Vivo Evaluation of Lung Microwave Ablation in a Porcine Tumor Mimic Model

    SciTech Connect

    Planche, Olivier; Teriitehau, Christophe; Boudabous, Sana; Robinson, Joey Marie; Rao, Pramod; Deschamps, Frederic; Farouil, Geoffroy; Baere, Thierry de

    2013-02-15

    To evaluate the microwave ablation of created tumor mimics in the lung of a large animal model (pigs), with examination of the ablative synergy of multiple antennas. Fifty-six tumor-mimic models of various sizes were created in 15 pigs by using barium-enriched minced collected thigh muscle injected into the lung of the same animal. Tumors were ablated under fluoroscopic guidance by single-antenna and multiple-antenna microwaves. Thirty-five tumor models were treated in 11 pigs with a single antenna at 75 W for 15 min, with 15 measuring 20 mm in diameter, 10 measuring 30 mm, and 10 measuring 40 mm. Mean circularity of the single-antenna ablation zones measured 0.64 {+-} 0.12, with a diameter of 35.7 {+-} 8.7 mm along the axis of the antenna and 32.7 {+-} 12.8 mm perpendicular to the feeding point. Multiple-antenna delivery of 75 W for 15 min caused intraprocedural death of 2 animals; modified protocol to 60 W for 10 min resulted in an ablation zone with a diameter of 43.0 {+-} 7.7 along the axis of the antenna and 54.8 {+-} 8.5 mm perpendicular to the feeding point; circularity was 0.70 {+-} 0.10. A single microwave antenna can create ablation zones large enough to cover lung tumor mimic models of {<=}4 cm with no heat sink effect from vessels of {<=}6 mm. Synergic use of 3 antennas allows ablation of larger volumes than single-antenna or radiofrequency ablation, but great caution must be taken when 3 antennas are used simultaneously in the lung in clinical practice.

  19. Radiofrequency interstitial tumor ablation: dry electrode.

    PubMed

    Johnson, D Brooke; Cadeddu, Jeffrey A

    2003-10-01

    With the shift in the treatment of small renal tumors from radical extirpative surgery to nephron-sparing approaches, dry-electrode radiofrequency ablation (RFA) has emerged as one potential modality. This application of RF energy leads to the production of heat within the treatment zone secondary to the native impedance of living tissue. Animal studies and human clinical series have demonstrated that RFA can create controlled, targeted, reproducible, and lethal lesions. Most clinical series have reported promising results, although some authors question the totality of tumor destruction by RFA. With time, the efficacy of RFA, as measured by patient survival, will be determined. Once this is known, RFA may be compared with other therapeutic modalities for small renal tumors to determine its place.

  20. Grain-size effects on the closure temperature of white mica in a crustal-scale extensional shear zone - Implications of in-situ 40Ar/39Ar laser-ablation of white mica for dating shearing and cooling (Tauern Window, Eastern Alps)

    NASA Astrophysics Data System (ADS)

    Scharf, Andreas; Handy, Mark R.; Schmid, Stefan M.; Favaro, Silvia; Sudo, Masafumi; Schuster, Ralf; Hammerschmidt, Konrad

    2016-04-01

    In-situ 40Ar/39Ar laser ablation dating of white-mica grains was performed on samples from the footwall of a crustal-scale extensional fault (Katschberg Normal Fault; KNF) that accommodated eastward orogen-parallel displacement of Alpine orogenic crust in the eastern part of the Tauern Window. This dating yields predominantly cooling ages ranging from 31 to 13 Myr, with most ages clustering between 21 and 17 Myr. Folded white micas that predate the main Katschberg foliation yield, within error, the same ages as white-mica grains that overgrow this foliation. However, the absolute ages of both generations are older at the base (20 Myr) where their grain size is larger (300-500 μm), than at the top and adjacent to the hangingwall (17 Myr) of this shear zone where grain size is smaller (< 100-300 μm). This fining-upward trend of white-mica grain size within the KNF is associated with a reduction of the closure temperature from the base (~ 445 °C) to the top (< 400 °C) and explains the counter-intuitive trend of downward-increasing age of cooling in the footwall. The new data show that rapid cooling within the KNF of the eastern Tauern Window started sometime before 21 Myr according to the 40Ar/39Ar white-mica cooling ages and between 25-21 Myr according to the new Rb/Sr white-mica ages, i.e., shortly after the attainment of the thermal peak in the Tauern Window at ~ 25 Myr ago. These new data, combined with literature data, support earlier cooling in the eastern part of then Tauern Window than in the western part by some 3-5 Myr.

  1. Bone and Soft Tissue Ablation

    PubMed Central

    Foster, Ryan C.B.; Stavas, Joseph M.

    2014-01-01

    Bone and soft tissue tumor ablation has reached widespread acceptance in the locoregional treatment of various benign and malignant musculoskeletal (MSK) lesions. Many principles of ablation learned elsewhere in the body are easily adapted to the MSK system, particularly the various technical aspects of probe/antenna design, tumoricidal effects, selection of image guidance, and methods to reduce complications. Despite the common use of thermal and chemical ablation procedures in bone and soft tissues, there are few large clinical series that show longitudinal benefit and cost-effectiveness compared with conventional methods, namely, surgery, external beam radiation, and chemotherapy. Percutaneous radiofrequency ablation of osteoid osteomas has been evaluated the most and is considered a first-line treatment choice for many lesions. Palliation of painful metastatic bone disease with thermal ablation is considered safe and has been shown to reduce pain and analgesic use while improving quality of life for cancer patients. Procedure-related complications are rare and are typically easily managed. Similar to all interventional procedures, bone and soft tissue lesions require an integrated approach to disease management to determine the optimum type of and timing for ablation techniques within the context of the patient care plan. PMID:25053865

  2. Dimension of chaotic attractors

    SciTech Connect

    Farmer, J.D.; Ott, E.; Yorke, J.A.

    1982-09-01

    Dimension is perhaps the most basic property of an attractor. In this paper we discuss a variety of different definitions of dimension, compute their values for a typical example, and review previous work on the dimension of chaotic attractors. The relevant definitions of dimension are of two general types, those that depend only on metric properties, and those that depend on probabilistic properties (that is, they depend on the frequency with which a typical trajectory visits different regions of the attractor). Both our example and the previous work that we review support the conclusion that all of the probabilistic dimensions take on the same value, which we call the dimension of the natural measure, and all of the metric dimensions take on a common value, which we call the fractal dimension. Furthermore, the dimension of the natural measure is typically equal to the Lyapunov dimension, which is defined in terms of Lyapunov numbers, and thus is usually far easier to calculate than any other definition. Because it is computable and more physically relevant, we feel that the dimension of the natural measure is more important than the fractal dimension.

  3. Focal Hydrothermal Ablation: Preliminary Investigation of a New Concept

    SciTech Connect

    Roy, Sumit

    2013-08-01

    PurposeTo determine whether focal tissue ablation is possible with interstitial instillation of steam.MethodsFresh swine livers were used. Through a 20 gauge needle, steam was instilled every 5 s, 3 (n = 5), 6 (n = 5), 9 (n = 5), or 12 (n = 5 + 5) times in a liver lobe. The ablated zones were sectioned parallel (n = 20) or perpendicular (n = 5) to the needle track. The longitudinal long and short axis diameters, or transverse long and short axis diameters of areas with discoloration on macroscopic examination, were measured. The experiment was repeated in vivo on a pig. Steam instillation was performed once every 5 s for 5 min in the liver (n = 3) and in muscle (n = 4), and temperature changes at three neighboring sites were monitored. Long and short axis diameters of the discolored areas were measured.ResultsA well-defined area of discoloration was invariably present at the site of steam instillation. The median longitudinal long axis diameter were 2.0, 2.5, 2.5, and 3.5 cm for 3, 6, 9, and 12 steam instillations in vitro, while median short axis diameters were 1.0, 1.5, 1.5, and 1.5 cm, respectively. Six attempts at ablation in vivo could be successfully completed. The long axis diameters of the ablated zones in the liver were 7.0 and 8.0 cm, while in muscle it ranged from 5.5 to 7.0 cm.ConclusionInstillation of steam in the liver in vitro and in vivo, and in muscle in vivo rapidly leads to circumscribed zones of coagulation necrosis.

  4. Computed Tomography-Guided Radiofrequency Ablation Following Transcatheter Arterial Embolization in Treatment of Large Hepatic Hemangiomas.

    PubMed

    Ji, Jiansong; Gao, Jun; Zhao, Lizhen; Tu, Jianfei; Song, Jingjing; Sun, Wenbing

    2016-04-01

    The aim of the study was to evaluate the feasibility, safety, and efficacy of computed tomography (CT)-guided radiofrequency (RF) ablation combined with transcatheter arterial embolization (TAE) to treat large (≥10 cm) hepatic hemangiomas. We retrospectively reviewed our sequential experience with 15 large hepatic hemangiomas in 15 patients. The mean diameter of the 15 hemangiomas was 13.0 ± 2.2 cm (10.0-16.0 cm). RF ablation combined with TAE treatment was performed successfully in all patients. The mean diameter of the hemangiomas decreased from 13.0 ± 2.2 to 7.1 ± 2.0 cm (P < 0.001) after TAE treatment. Out of 15 hepatic hemangiomas, 14 (93.3%) showed no enhancement on CT or MRI indicating complete ablation after RF treatment. The mean diameter of the ablation zone decreased to 6.1 ± 2.0 cm 1 month after ablation and further decreased to 4.9 ± 1.6 cm 6 months after ablation. There were 6 complications related to the ablation in 4 patients. According to the Dindo-Clavien classification, all the complications were minor (Grade I). RF ablation combined with TAE is a safe and effective treatment for large hepatic hemangiomas. TAE can improve the disruption of lesion blood supply and reduce lesion size to facilitate subsequent RF ablation and reduce the risk of ablation-related complications.

  5. Silver nano-entities through ultrafast double ablation in aqueous media for surface enhanced Raman scattering and photonics applications

    NASA Astrophysics Data System (ADS)

    Krishna Podagatlapalli, G.; Hamad, Syed; Tewari, Surya P.; Sreedhar, S.; Prasad, Muvva D.; Venugopal Rao, S.

    2013-02-01

    We have fabricated stable silver nanoparticles (NPs) and nanostructures (NSs) effectively through double ablation of bulk silver substrate immersed in double distilled water using ˜2 ps laser pulses. The effects of multiple/double/single ablation on silver substrates via surface morphology studies along with average size distribution of Ag NPs were investigated. Prepared Ag NPs in solution exhibited yellow color with an absorption peak near 410 nm, assigned to localized surface Plasmon resonance of nano-sized silver. Depending on the ablation parameters average sizes observed were ˜13 nm/˜17 nm in multiple/double ablation case and ˜7 nm in single ablation case. High resolution transmission electron microscope studies highlighted that most of the Ag NPs were spherical and polycrystalline in nature. Surface morphology of the substrates was characterized by field emission scanning electron microscope and atomic force microscope. A different scenario was observed in the double ablation case compared to single/multiple ablation case. Double ablation resulted in dome like NSs on the substrate with dimensions of few hundreds of nanometers while single ablation did not. Nonlinear optical (NLO) properties of Ag NPs were investigated using Z-scan technique with ˜2 ps pulses and corresponding NLO coefficients were obtained. Surface enhanced Raman scattering (SERS) studies on multiple/double ablated Ag substrates with adsorbed Rhodamine 6G molecules were carried out using excitation wavelengths of 532 nm, 785 nm, and three orders of enhancement in Raman signal intensity was observed. Furthermore, influence of laser fluence on the fabrication of SERS active Ag substrates with double ablation was also investigated. In this case, Raman spectra of adsorbed Research Department eXplosive (RDX) molecules on ablated surfaces were recorded for 532 nm and 785 nm excitation. Enhancements up to 460 were observed from substrates fabricated at fluences of 12 J/cm2, 16 J/cm2 with

  6. Glass particles produced by laser ablation for ICP-MSmeasurements

    SciTech Connect

    Gonzalez, J.; Liu, C.; Wen, S.; Mao, X.; Russo, R.E.

    2007-06-01

    Pulsed laser ablation (266nm) was used to generate glass particles from two sets of standard reference materials using femtosecond (150fs) and nanosecond (4ns) laser pulses with identical fluences of 50 J cm{sup -2}. Scanning electron microscopy (SEM) images of the collected particles revealed that there are more and larger agglomerations of particles produced by nanosecond laser ablation. In contrast to the earlier findings for metal alloy samples, no correlation between the concentration of major elements and the median particle size was found. When the current data on glass were compared with the metal alloy data, there were clear differences in terms of particle size, crater depth, heat affected zone, and ICP-MS response. For example, glass particles were larger than metal alloy particles, the craters in glass were less deep than craters in metal alloys, and damage to the sample was less pronounced in glass compared to metal alloys samples. The femtosecond laser generated more intense ICP-MS signals compared to nanosecond laser ablation for both types of samples, although glass sample behavior was more similar between ns and fs-laser ablation than for metals alloys.

  7. Percutaneous Tumor Ablation Tools: Microwave, Radiofrequency, or Cryoablation—What Should You Use and Why?

    PubMed Central

    Lubner, Meghan G.; Ziemlewicz, Timothy J.; Lee, Fred T.; Brace, Christopher L.

    2014-01-01

    Image-guided thermal ablation is an evolving and growing treatment option for patients with malignant disease of multiple organ systems. Treatment indications have been expanding to include benign tumors as well. Specifically, the most prevalent indications to date have been in the liver (primary and metastatic disease, as well as benign tumors such as hemangiomas and adenomas), kidney (primarily renal cell carcinoma, but also benign tumors such as angiomyolipomas and oncocytomas), lung (primary and metastatic disease), and soft tissue and/or bone (primarily metastatic disease and osteoid osteomas). Each organ system has different underlying tissue characteristics, which can have profound effects on the resulting thermal changes and ablation zone. Understanding these issues is important for optimizing clinical results. In addition, thermal ablation technology has evolved rapidly during the past several decades, with substantial technical and procedural improvements that can help improve clinical outcomes and safety profiles. Staying up to date on these developments is challenging but critical because the physical properties underlying the different ablation modalities and the appropriate use of adjuncts will have a tremendous effect on treatment results. Ultimately, combining an understanding of the physical properties of the ablation modalities with an understanding of the thermal kinetics in tissue and using the most appropriate ablation modality for each patient are key to optimizing clinical outcomes. Suggested algorithms are described that will help physicians choose among the various ablation modalities for individual patients. ©RSNA, 2014 PMID:25208284

  8. Comparative study on laser tissue ablation between PV and HPS lasers

    NASA Astrophysics Data System (ADS)

    Kang, Hyun Wook; Jebens, David; Mitchell, Gerald; Koullick, Ed

    2008-02-01

    Laser therapy for obstructive benign prostatic hyperplasia (BPH) has gained broad adoption due to effective tissue removal, immediate hemostasis, and minor complications. The aim of this study is to quantitatively compare ablation characteristics of PV (Photoselective Vaporization) and the newly introduced HPS (High Performance System) 532 nm lasers. Bovine prostatic tissues were ablated in vitro, using a custom-made scanning system. Laser-induced volume produced by two lasers was quantified as a function of applied power, fiber working distance (WD), and treatment speed. Given the same power of 80 W and speed of 4 mm/s, HPS created up to 50 % higher tissue ablation volume than PV did. PV induced a rapid decrease of ablation volume when WD increased from 0.5 mm to 3 mm while HPS yielded almost constant tissue removal up to 3 mm for both 80 W and 120 W. As the treatment speed increased, both lasers reached saturation in tissue ablation volume. Lastly, both PV and HPS lasers exhibited approximately 1 mm thick heat affected zone (HAZ) in this study although HPS created twice deeper ablation channels with a depth of up to 4 mm. Due to a smaller beam size and a higher output power, HPS maximized tissue ablation rate with minimal thermal effects to the adjacent tissue. Furthermore, more collimated beam characteristics provides more spatial flexibility and may even help to decrease the rate of fiber degradation associated with thermal damage from debris reattachment to the tip.

  9. Current hot potatoes in atrial fibrillation ablation.

    PubMed

    Roten, Laurent; Derval, Nicolas; Pascale, Patrizio; Scherr, Daniel; Komatsu, Yuki; Shah, Ashok; Ramoul, Khaled; Denis, Arnaud; Sacher, Frédéric; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre

    2012-11-01

    Atrial fibrillation (AF) ablation has evolved to the treatment of choice for patients with drug-resistant and symptomatic AF. Pulmonary vein isolation at the ostial or antral level usually is sufficient for treatment of true paroxysmal AF. For persistent AF ablation, drivers and perpetuators outside of the pulmonary veins are responsible for AF maintenance and have to be targeted to achieve satisfying arrhythmia-free success rate. Both complex fractionated atrial electrogram (CFAE) ablation and linear ablation are added to pulmonary vein isolation for persistent AF ablation. Nevertheless, ablation failure and necessity of repeat ablations are still frequent, especially after persistent AF ablation. Pulmonary vein reconduction is the main reason for arrhythmia recurrence after paroxysmal and to a lesser extent after persistent AF ablation. Failure of persistent AF ablation mostly is a consequence of inadequate trigger ablation, substrate modification or incompletely ablated or reconducting linear lesions. In this review we will discuss these points responsible for AF recurrence after ablation and review current possibilities on how to overcome these limitations. PMID:22920482

  10. Femtosecond laser ablation of enamel

    NASA Astrophysics Data System (ADS)

    Le, Quang-Tri; Bertrand, Caroline; Vilar, Rui

    2016-06-01

    The surface topographical, compositional, and structural modifications induced in human enamel by femtosecond laser ablation is studied. The laser treatments were performed using a Yb:KYW chirped-pulse-regenerative amplification laser system (560 fs and 1030 nm) and fluences up to 14 J/cm2. The ablation surfaces were studied by scanning electron microscopy, grazing incidence x-ray diffraction, and micro-Raman spectroscopy. Regardless of the fluence, the ablation surfaces were covered by a layer of resolidified material, indicating that ablation is accompanied by melting of hydroxyapatite. This layer presented pores and exploded gas bubbles, created by the release of gaseous decomposition products of hydroxyapatite (CO2 and H2O) within the liquid phase. In the specimen treated with 1-kHz repetition frequency and 14 J/cm2, thickness of the resolidified material is in the range of 300 to 900 nm. The micro-Raman analysis revealed that the resolidified material contains amorphous calcium phosphate, while grazing incidence x-ray diffraction analysis allowed detecting traces of a calcium phosphate other than hydroxyapatite, probably β-tricalcium phosphate Ca3), at the surface of this specimen. The present results show that the ablation of enamel involves melting of enamel's hydroxyapatite, but the thickness of the altered layer is very small and thermal damage of the remaining material is negligible.

  11. Femtosecond laser ablation of enamel

    NASA Astrophysics Data System (ADS)

    Le, Quang-Tri; Bertrand, Caroline; Vilar, Rui

    2016-06-01

    The surface topographical, compositional, and structural modifications induced in human enamel by femtosecond laser ablation is studied. The laser treatments were performed using a Yb:KYW chirped-pulse-regenerative amplification laser system (560 fs and 1030 nm) and fluences up to 14 J/cm2. The ablation surfaces were studied by scanning electron microscopy, grazing incidence x-ray diffraction, and micro-Raman spectroscopy. Regardless of the fluence, the ablation surfaces were covered by a layer of resolidified material, indicating that ablation is accompanied by melting of hydroxyapatite. This layer presented pores and exploded gas bubbles, created by the release of gaseous decomposition products of hydroxyapatite (CO2 and H2O) within the liquid phase. In the specimen treated with 1-kHz repetition frequency and 14 J/cm2, thickness of the resolidified material is in the range of 300 to 900 nm. The micro-Raman analysis revealed that the resolidified material contains amorphous calcium phosphate, while grazing incidence x-ray diffraction analysis allowed detecting traces of a calcium phosphate other than hydroxyapatite, probably β-tricalcium phosphate Ca3), at the surface of this specimen. The present results show that the ablation of enamel involves melting of enamel's hydroxyapatite, but the thickness of the altered layer is very small and thermal damage of the remaining material is negligible.

  12. Laser ablation studies of concrete

    SciTech Connect

    Savina, M.; Xu, Z.; Wang, Y.; Reed, C.; Pellin, M.

    1999-10-20

    Laser ablation was studied as a means of removing radioactive contaminants from the surface and near-surface regions of concrete. The authors present the results of ablation tests on cement and concrete samples using a 1.6 kW pulsed Nd:YAG laser with fiber optic beam delivery. The laser-surface interaction was studied using cement and high density concrete as targets. Ablation efficiency and material removal rates were determined as functions of irradiance and pulse overlap. Doped samples were also ablated to determine the efficiency with which surface contaminants were removed and captured in the effluent. The results show that the cement phase of the material melts and vaporizes, but the aggregate portion (sand and rock) fragments. The effluent consists of both micron-size aerosol particles and chunks of fragmented aggregate material. Laser-induced optical emission spectroscopy was used to analyze the surface during ablation. Analysis of the effluent showed that contaminants such as cesium and strontium were strongly segregated into different regions of the particle size distribution of the aerosol.

  13. Fragmentation and ablation during entry

    SciTech Connect

    Canavan, G.H.

    1997-09-01

    This note discusses objects that both fragment and ablate during entry, using the results of previous reports to describe the velocity, pressure, and fragmentation of entering objects. It shows that the mechanisms used there to describe the breakup of non-ablating objects during deceleration remain valid for most ablating objects. It treats coupled fragmentation and ablation during entry, building on earlier models that separately discuss the entry of objects that are hard, whose high heat of ablation permits little erosion, and those who are strong whose strength prevents fragmentation, which are discussed in ``Radiation from Hard Objects,`` ``Deceleration and Radiation of Strong, Hard, Asteroids During Atmospheric Impact,`` and ``Meteor Signature Interpretation.`` This note provides a more detailed treatment of the further breakup and separation of fragments during descent. It replaces the constraint on mass per unit area used earlier to determine the altitude and magnitude of peak power radiation with a detailed analytic solution of deceleration. Model predictions are shown to be in agreement with the key features of numerical calculations of deceleration. The model equations are solved for the altitudes of maximum radiation, which agree with numerical integrations. The model is inverted analytically to infer object size and speed from measurements of peak power and altitude to provide a complete model for the approximate inversion of meteor data.

  14. Evaluation of explosive sublimation as the mechanism of nanosecond laser ablation of tungsten under vacuum conditions

    NASA Astrophysics Data System (ADS)

    Oderji, Hassan Yousefi; Farid, Nazar; Sun, Liying; Fu, Cailong; Ding, Hongbin

    2016-08-01

    A non-equilibrium mechanism for nanosecond laser ablation is suggested herein, and its predictions are compared to the results of W experiments performed under vacuum conditions. A mechanism of particle formation is explained via this model, with partial sublimation of the superheated irradiated zone of the target considered to be the mechanism of laser ablation. In this study, a mixture of vapor and particles was explosively generated and subsequently prevented the rest of a laser pulse from reaching its intended target. This mechanism was found to play an essential role in the ablation of W under vacuum conditions, and it provides a theoretical justification for particle formation. Moreover, special considerations were taken into account for the expansion of plasma into a vacuum. The model was evaluated by measuring the mass of ablated particles using a quartz crystal deposition monitor and time-resolved optical emission spectroscopy. The results of this model were found to be in good agreement with experimental values.

  15. Interstitial ultrasound ablation of vertebral and paraspinal tumours: Parametric and patient-specific simulations

    PubMed Central

    Scott, Serena J.; Salgaonkar, Vasant; Prakash, Punit; Burdette, E. Clif; Diederich, Chris J.

    2015-01-01

    Purpose Theoretical parametric and patient-specific models are applied to assess the feasibility of interstitial ultrasound ablation of tumours in and near the spine and to identify potential treatment delivery strategies. Methods 3D patient-specific finite element models (n=11) of interstitial ultrasound ablation of tumours associated with spine were generated. Gaseous nerve insulation and various applicator configurations, frequencies (3 and 7 MHz), placement trajectories, and tumour locations were simulated. Parametric studies with multilayered models investigated the impacts of tumour attenuation, tumour dimension, and the thickness of bone insulating critical structures. Temperature and thermal dose were calculated to define ablation (>240 equivalent minutes at 43°C (EM43°C)) and safety margins (<45°C & <6 EM43°C), and to determine performance and required delivery parameters. Results Osteolytic tumours (≤44 mm) encapsulated by bone could be successfully ablated with 7 MHz interstitial ultrasound (8.1-16.6 W/cm2, 120-5900 J, 0.4-15 min). Ablation of tumours (94.6-100% volumetric) 0-14.5 mm from the spinal canal was achieved within 3-15 min without damaging critical nerves. 3 MHz devices provided faster ablation (390 versus 930 s) of an 18 mm diameter osteoblastic (high bone content) volume than 7 MHz devices. Critical anatomy in proximity to the tumour could be protected by selection of appropriate applicator configurations, active sectors, and applied power schemas, and through gaseous insulation. Preferential ultrasound absorption at bone surfaces facilitated faster, more effective ablations in osteolytic tumours and provided isolation of ablative energies and temperatures. Conclusions Parametric and patient-specific studies demonstrated the feasibility and potential advantages of interstitial ultrasound ablation treatment of paraspinal and osteolytic vertebral tumours. PMID:25017322

  16. Theoretical Modeling for Hepatic Microwave Ablation

    PubMed Central

    Prakash, Punit

    2010-01-01

    Thermal tissue ablation is an interventional procedure increasingly being used for treatment of diverse medical conditions. Microwave ablation is emerging as an attractive modality for thermal therapy of large soft tissue targets in short periods of time, making it particularly suitable for ablation of hepatic and other tumors. Theoretical models of the ablation process are a powerful tool for predicting the temperature profile in tissue and resultant tissue damage created by ablation devices. These models play an important role in the design and optimization of devices for microwave tissue ablation. Furthermore, they are a useful tool for exploring and planning treatment delivery strategies. This review describes the status of theoretical models developed for microwave tissue ablation. It also reviews current challenges, research trends and progress towards development of accurate models for high temperature microwave tissue ablation. PMID:20309393

  17. Image-Guided Ablation of Adrenal Lesions

    PubMed Central

    Yamakado, Koichiro

    2014-01-01

    Although laparoscopic adrenalectomy has remained the standard of care for the treatment for adrenal tumors, percutaneous image-guided ablation therapy, such as chemical ablation, radiofrequency ablation, cryoablation, and microwave ablation, has been shown to be clinically useful in many nonsurgical candidates. Ablation therapy has been used to treat both functioning adenomas and malignant tumors, including primary adrenal carcinoma and metastasis. For patients with functioning adenomas, biochemical and symptomatic improvement is achieved in 96 to 100% after ablation; for patients with malignant adrenal neoplasms, however, the survival benefit from ablation therapy remains unclear, though good initial results have been reported. This article outlines the current role of ablation therapy for adrenal lesions, as well as identifying some of the technical considerations for this procedure. PMID:25049444

  18. Femtosecond lasers for machining of transparent, brittle materials: ablative vs. non-ablative femtosecond laser processing

    NASA Astrophysics Data System (ADS)

    Hendricks, F.; Matylitsky, V. V.

    2016-03-01

    This paper focuses on precision machining of transparent materials by means of ablative and non-ablative femtosecond laser processing. Ablation technology will be compared with a newly developed patent pending non-ablative femtosecond process, ClearShapeTM, using the Spectra-Physics Spirit industrial femtosecond laser.

  19. Microwave ablation at 915 MHz vs 2.45 GHz: A theoretical and experimental investigation

    SciTech Connect

    Curto, Sergio; Taj-Eldin, Mohammed; Fairchild, Dillon; Prakash, Punit

    2015-11-15

    Purpose: The relationship between microwave ablation system operating frequency and ablation performance is not currently well understood. The objective of this study was to comparatively assess the differences in microwave ablation at 915 MHz and 2.45 GHz. Methods: Analytical expressions for electromagnetic radiation from point sources were used to compare power deposition at the two frequencies of interest. A 3D electromagnetic-thermal bioheat transfer solver was implemented with the finite element method to characterize power deposition and thermal ablation with asymmetrical insulated dipole antennas (single-antenna and dual-antenna synchronous arrays). Simulation results were validated against experiments in ex vivo tissue. Results: Theoretical, computational, and experimental results indicated greater power deposition and larger diameter ablation zones when using a single insulated microwave antenna at 2.45 GHz; experimentally, 32 ± 4.1 mm and 36.3 ± 1.0 mm for 5 and 10 min, respectively, at 2.45 GHz, compared to 24 ± 1.7 mm and 29.5 ± 0.6 mm at 915 MHz, with 30 W forward power at the antenna input port. In experiments, faster heating was observed at locations 5 mm (0.91 vs 0.49 °C/s) and 10 mm (0.28 vs 0.15 °C/s) from the antenna operating at 2.45 GHz. Larger ablation zones were observed with dual-antenna arrays at 2.45 GHz; however, the differences were less pronounced than for single antennas. Conclusions: Single- and dual-antenna arrays systems operating at 2.45 GHz yield larger ablation zone due to greater power deposition in proximity to the antenna, as well as greater role of thermal conduction.

  20. Microwave ablation of hepatocellular carcinoma

    PubMed Central

    Poggi, Guido; Tosoratti, Nevio; Montagna, Benedetta; Picchi, Chiara

    2015-01-01

    Although surgical resection is still the optimal treatment option for early-stage hepatocellular carcinoma (HCC) in patients with well compensated cirrhosis, thermal ablation techniques provide a valid non-surgical treatment alternative, thanks to their minimal invasiveness, excellent tolerability and safety profile, proven efficacy in local disease control, virtually unlimited repeatability and cost-effectiveness. Different energy sources are currently employed in clinics as physical agents for percutaneous or intra-surgical thermal ablation of HCC nodules. Among them, radiofrequency (RF) currents are the most used, while microwave ablations (MWA) are becoming increasingly popular. Starting from the 90s’, RF ablation (RFA) rapidly became the standard of care in ablation, especially in the treatment of small HCC nodules; however, RFA exhibits substantial performance limitations in the treatment of large lesions and/or tumors located near major heat sinks. MWA, first introduced in the Far Eastern clinical practice in the 80s’, showing promising results but also severe limitations in the controllability of the emitted field and in the high amount of power employed for the ablation of large tumors, resulting in a poor coagulative performance and a relatively high complication rate, nowadays shows better results both in terms of treatment controllability and of overall coagulative performance, thanks to the improvement of technology. In this review we provide an extensive and detailed overview of the key physical and technical aspects of MWA and of the currently available systems, and we want to discuss the most relevant published data on MWA treatments of HCC nodules in regard to clinical results and to the type and rate of complications, both in absolute terms and in comparison with RFA. PMID:26557950

  1. Microwave ablation of hepatocellular carcinoma.

    PubMed

    Poggi, Guido; Tosoratti, Nevio; Montagna, Benedetta; Picchi, Chiara

    2015-11-01

    Although surgical resection is still the optimal treatment option for early-stage hepatocellular carcinoma (HCC) in patients with well compensated cirrhosis, thermal ablation techniques provide a valid non-surgical treatment alternative, thanks to their minimal invasiveness, excellent tolerability and safety profile, proven efficacy in local disease control, virtually unlimited repeatability and cost-effectiveness. Different energy sources are currently employed in clinics as physical agents for percutaneous or intra-surgical thermal ablation of HCC nodules. Among them, radiofrequency (RF) currents are the most used, while microwave ablations (MWA) are becoming increasingly popular. Starting from the 90s', RF ablation (RFA) rapidly became the standard of care in ablation, especially in the treatment of small HCC nodules; however, RFA exhibits substantial performance limitations in the treatment of large lesions and/or tumors located near major heat sinks. MWA, first introduced in the Far Eastern clinical practice in the 80s', showing promising results but also severe limitations in the controllability of the emitted field and in the high amount of power employed for the ablation of large tumors, resulting in a poor coagulative performance and a relatively high complication rate, nowadays shows better results both in terms of treatment controllability and of overall coagulative performance, thanks to the improvement of technology. In this review we provide an extensive and detailed overview of the key physical and technical aspects of MWA and of the currently available systems, and we want to discuss the most relevant published data on MWA treatments of HCC nodules in regard to clinical results and to the type and rate of complications, both in absolute terms and in comparison with RFA. PMID:26557950

  2. An MRI guided system for prostate laser ablation with treatment planning and multi-planar temperature monitoring

    NASA Astrophysics Data System (ADS)

    Xu, Sheng; Agarwal, Harsh; Bernardo, Marcelino; Seifabadi, Reza; Turkbey, Baris; Partanen, Ari; Negussie, Ayele; Glossop, Neil; Choyke, Peter; Pinto, Peter; Wood, Bradford J.

    2016-03-01

    Prostate cancer is often over treated with standard treatment options which impact the patients' quality of life. Laser ablation has emerged as a new approach to treat prostate cancer while sparing the healthy tissue around the tumor. Since laser ablation has a small treatment zone with high temperature, it is necessary to use accurate image guidance and treatment planning to enable full ablation of the tumor. Intraoperative temperature monitoring is also desirable to protect critical structures from being damaged in laser ablation. In response to these problems, we developed a navigation platform and integrated it with a clinical MRI scanner and a side firing laser ablation device. The system allows imaging, image guidance, treatment planning and temperature monitoring to be carried out on the same platform. Temperature sensing phantoms were developed to demonstrate the concept of iterative treatment planning and intraoperative temperature monitoring. Retrospective patient studies were also conducted to show the clinical feasibility of the system.

  3. Micro-ablation with high power pulsed copper vapor lasers.

    PubMed

    Knowles, M

    2000-07-17

    Visible and UV lasers with nanosecond pulse durations, diffraction-limited beam quality and high pulse repetition rates have demonstrated micro-ablation in a wide variety of materials with sub-micron precision and sub-micron-sized heat-affected zones. The copper vapour laser (CVL) is one of the important industrial lasers for micro-ablation applications. Manufacturing applications for the CVL include orifice drilling in fuel injection components and inkjet printers, micro-milling of micromoulds, via hole drilling in printed circuit boards and silicon machining. Recent advances in higher power (100W visible, 5W UV), diffraction-limited, compact CVLs are opening new possibilities for manufacturing with this class of nanosecond laser.

  4. Transhemangioma Ablation of Hepatocellular Carcinoma

    SciTech Connect

    Pua, Uei

    2012-12-15

    Radiofrequency ablation (RFA) is a well-established treatment modality in the treatment of early hepatocellular carcinoma (HCC) [1]. Safe trajectory of the RFA probe is crucial in decreasing collateral tissue damage and unwarranted probe transgression. As a percutaneous technique, however, the trajectory of the needle is sometimes constrained by the available imaging plane. The presence of a hemangioma beside an HCC is uncommon but poses the question of safety related to probe transgression. We hereby describe a case of transhemangioma ablation of a dome HCC.

  5. Photochemical ablation of organic solids

    NASA Astrophysics Data System (ADS)

    Yingling, Yaroslava G.; Garrison, Barbara J.

    2003-04-01

    We have investigated by molecular dynamics simulations the ablation of material that is onset by photochemical processes. We compare this system with only photochemical processes to a system containing photochemical and photothermal processes. The simulations reveal that ablation by purely photochemical processes is accompanied by the ejection of relatively cold massive molecular clusters from the surface of the sample. The top of the plume exhibits high temperatures whereas the residual part of the sample is cold. The removal of the damaged material through big molecular cluster ejection is consistent with experimental observations of low heat damage of material.

  6. Laser ablation based fuel ignition

    DOEpatents

    Early, J.W.; Lester, C.S.

    1998-06-23

    There is provided a method of fuel/oxidizer ignition comprising: (a) application of laser light to a material surface which is absorptive to the laser radiation; (b) heating of the material surface with the laser light to produce a high temperature ablation plume which emanates from the heated surface as an intensely hot cloud of vaporized surface material; and (c) contacting the fuel/oxidizer mixture with the hot ablation cloud at or near the surface of the material in order to heat the fuel to a temperature sufficient to initiate fuel ignition. 3 figs.

  7. Laser ablation based fuel ignition

    DOEpatents

    Early, James W.; Lester, Charles S.

    1998-01-01

    There is provided a method of fuel/oxidizer ignition comprising: (a) application of laser light to a material surface which is absorptive to the laser radiation; (b) heating of the material surface with the laser light to produce a high temperature ablation plume which emanates from the heated surface as an intensely hot cloud of vaporized surface material; and (c) contacting the fuel/oxidizer mixture with the hot ablation cloud at or near the surface of the material in order to heat the fuel to a temperature sufficient to initiate fuel ignition.

  8. Atrial Fibrillation Ablation and Stroke.

    PubMed

    Aagaard, Philip; Briceno, David; Csanadi, Zoltan; Mohanty, Sanghamitra; Gianni, Carola; Trivedi, Chintan; Nagy-Baló, Edina; Danik, Stephan; Barrett, Conor; Santoro, Francesco; Burkhardt, J David; Sanchez, Javier; Natale, Andrea; Di Biase, Luigi

    2016-05-01

    Catheter ablation has become a widely available and accepted treatment to restore sinus rhythm in atrial fibrillation patients who fail antiarrhythmic drug therapy. Although generally safe, the procedure carries a non-negligible risk of complications, including periprocedural cerebral insults. Uninterrupted anticoagulation, maintenance of an adequate ACT during the procedure, and measures to avoid and detect thrombus build-up on sheaths and atheters during the procedure, appears useful to reduce the risk of embolic events. This is a review of the incidence, mechanisms, impact, and methods to reduce catheter ablation related cerebral insults. PMID:27150179

  9. Radiofrequency ablation of lung tumours

    PubMed Central

    Goh, PYT

    2006-01-01

    Radiofrequency ablation (RFA) is a well-established local therapy for hepatic malignancies. It is rapidly emerging as an effective treatment modality for small lesions elsewhere in the body, in particular, the kidney and the lung. It is a relatively safe and minimally invasive treatment for small lung malignancies, both primary and secondary. In particular, it is the preferred form of treatment for non-surgical candidates. This paper describes the technique employed for radiofrequency ablation of lung tumours, as well as the protocol established, at the Mount Elizabeth Hospital, Singapore. PMID:21614247

  10. Ablative Therapies for Barrett's Esophagus

    PubMed Central

    Garman, Katherine S.; Shaheen, Nicholas J.

    2011-01-01

    Barrett's esophagus has gained increased clinical attention because of its association with esophageal adenocarcinoma, a cancer with increasing incidence and poor survival rates. The goals of ablating Barrett's esophagus are to decrease esophageal cancer rates and to improve overall survival and quality of life. Different techniques have been developed and tested for their effectiveness eradicating Barrett's epithelium. This review assesses the literature associated with different ablative techniques. The safety and efficacy of different techniques are discussed. This review concludes with recommendations for the clinician, including specific strategies for patient care decisions for patients with Barrett's esophagus with varying degrees of dysplasia. PMID:21373836

  11. Tektite ablation - Some confirming calculations.

    NASA Technical Reports Server (NTRS)

    O'Keefe, J. A., III; Silver, A. D.; Cameron, W. S.; Adams , E. W.; Warmbrod, J. D.

    1973-01-01

    The calculation of tektite ablation has been redone, taking into account transient effects, internal radiation, melting and nonequilibrium vaporization of the glass, and the drag effect of the flanges. It is found that the results confirm the earlier calculations of Chapman and his group and of Adams and his co-workers. The general trend of the results is not sensitive to reasonable changes of the physical parameters. The ablation is predominantly by melting rather than by vaporization at all velocities up to 11 km/sec; this is surprising in view of the lack of detectable melt flow in most tektites. Chemical effects have not been considered.

  12. Damage in materials following ablation by ultrashort laser pulses: A molecular-dynamics study

    SciTech Connect

    Bouilly, Delphine; Perez, Danny; Lewis, Laurent J.

    2007-11-01

    The formation of craters following femtosecond- and picosecond-pulse laser ablation in the thermal regime is studied using a generic two-dimensional numerical model based on molecular-dynamics simulations and the Lennard-Jones potential. Femtosecond pulses are found to produce very clean craters through a combination of etching of the walls and the formation of a very thin heat affected zone. Our simulations also indicate that dislocations are emitted continuously during all of the ablation process (i.e., for hundreds of ps). For picosecond pulses, we observe much thicker heat affected zones which result from melting and recrystallization following the absorption of the light. In this case also, continuous emission of dislocations--though fewer in number--takes place throughout the ablation process.

  13. Lung Tumor Radiofrequency Ablation: Where Do We Stand?

    SciTech Connect

    Baere, Thierry de

    2011-04-15

    Today, radiofrequency ablation (RFA) of primary and metastatic lung tumor is increasingly used. Because RFA is most often used with curative intent, preablation workup must be a preoperative workup. General anesthesia provides higher feasibility than conscious sedation. The electrode positioning must be performed under computed tomography for sake of accuracy. The delivery of RFA must be adapted to tumor location, with different impedances used when treating tumors with or without pleural contact. The estimated rate of incomplete local treatment at 18 months was 7% (95% confidence interval, 3-14) per tumor, with incomplete treatment depicted at 4 months (n = 1), 6 months (n = 2), 9 months (n = 2), and 12 months (n = 2). Overall survival and lung disease-free survival at 18 months were, respectively, 71 and 34%. Size is a key point for tumor selection because large size is predictive of incomplete local treatment and poor survival. The ratio of ablation volume relative to tumor volume is predictive of complete ablation. Follow-up computed tomography that relies on the size of the ablation zone demonstrates the presence of incomplete ablation. Positron emission tomography might be an interesting option. Chest tube placement for pneumothorax is reported in 8 to 12%. Alveolar hemorrhage and postprocedure hemoptysis occurred in approximately 10% of procedures and rarely required specific treatment. Death was mostly related to single-lung patients and hilar tumors. No modification of forced expiratory volume in the first second between pre- and post-RFA at 2 months was found. RFA in the lung provides a high local efficacy rate. The use of RFA as a palliative tool in combination with chemotherapy remains to be explored.

  14. Catheter ablation of parahisian premature ventricular complex.

    PubMed

    Kim, Jun; Kim, Jeong Su; Park, Yong Hyun; Kim, June Hong; Chun, Kook Jin

    2011-12-01

    Catheter ablation is performed in selected patients with a symptomatic premature ventricular complex (PVC) or PVC-induced cardiomyopathy. Ablation of PVC from the His region has a high risk of inducing a complete atrioventricular block. Here we report successful catheter ablation of a parahisian PVC in a 63-year-old man.

  15. The role of cold volcanic debris in glacier ablation

    NASA Astrophysics Data System (ADS)

    Hobbs, L. K.; Gilbert, J. S.; Lane, S. J.

    2011-12-01

    Debris deposits on ice can either enhance or hinder glacial ablation relative to a clean ice surface. The effect of debris on ice is dependent on whether its thickness is above or below a critical thickness. This is the thickness at which ablation of the underlying ice equates to that of bare ice. It is dependent on the properties of the debris material, as well as local conditions. The small amount of published data available indicate that volcanic deposits have lower critical thickness values than non-volcanic deposits at similar latitudes and altitudes, suggesting that they are more effective insulators. Volcanic ash fall events are significant for glacial ablation because (1) they mantle topography and distribute well-sorted material over a wide area, and (2) the locations of Earth's glaciers often coincide with regions of active volcanism; at least 280 active volcanoes have ice or snow cover. At ice-capped volcanoes, volcanic material will also be deposited on glaciers by erosion and aeolian remobilisation. Volcán Sollipulli is an active, ice-filled caldera volcano in southern Chile (38.97°S:71.52°W) which last erupted 700 years ago. Satellite imagery and comparisons of field photographs show that the intra-caldera ice body is receding. The Sollipulli glacier is a local water resource and an increase in melting rate could produce lahars. Sollipulli lies between Llaima and Villarrica, two of the most active volcanoes in Chile, and the potential for its glacier to receive ablation-changing ash fall from other volcanoes in the Southern Volcanic Zone of the Andes is high. Indeed, it has in June-July 2011 received ash fall from Puyehue-Cordón Caulle volcano to the south. It is, therefore, important to understand the ice ablation effects of volcanic debris deposited both at Sollipulli and on glaciers worldwide. In February-March 2011, field experiments were conducted on the surface of Sollipulli glacier, on both ice and snow, in order to determine critical

  16. Modern Advances in Ablative TPS

    NASA Technical Reports Server (NTRS)

    Venkatapathy, Ethiraj

    2013-01-01

    Topics covered include: Physics of Hypersonic Flow and TPS Considerations. Destinations, Missions and Requirements. State of the Art Thermal Protection Systems Capabilities. Modern Advances in Ablative TPS. Entry Systems Concepts. Flexible TPS for Hypersonic Inflatable Aerodynamic Decelerators. Conformal TPS for Rigid Aeroshell. 3-D Woven TPS for Extreme Entry Environment. Multi-functional Carbon Fabric for Mechanically Deployable.

  17. Reconstruction of an ablated breast.

    PubMed

    Scarfì, A; Ordemann, K; Hüter, J

    1986-01-01

    It is the aim of the reconstruction of an ablated breast to repair the woman's integrity. The technique of this operation, according to Bomert, is the sliding of a flap of skin in the case of a horizontal breast scar. For the reconstruction, a silicone prosthesis is implanted which in most cases is prepectoral.

  18. Navigating between the Dimensions

    ERIC Educational Resources Information Center

    Fleron, Julian F.; Ecke, Volker

    2011-01-01

    Generations have been inspired by Edwin A. Abbott's profound tour of the dimensions in his novella "Flatland: A Romance of Many Dimensions" (1884). This well-known satire is the story of a flat land inhabited by geometric shapes trying to navigate the subtleties of their geometric, social, and political positions. In this article, the authors…

  19. Fast Conformal Thermal Ablation in the Prostate with Transurethral Multi-Sectored Ultrasound Devices and MR Guidance

    NASA Astrophysics Data System (ADS)

    Kinsey, Adam M.; Diederich, Chris J.; Nau, William H.; Ross, Anthony B.; Pauly, Kim Butts; Rieke, Viola; Sommer, Graham

    2007-05-01

    Transurethral ultrasound applicators incorporating an array of multisectored tubular transducers were evaluated in theoretical simulations and in vivo canine prostates under MR guidance as a method for fast, conformal thermal therapy of the prostate. Comprehensive simulations with a biothermal model investigated the effect on lesion creation of sector size, perfusion, treatment time, rectal cooling, prostate target dimensions, and feedback controller parameters (maximum temperature, pilot points at boundary, update times). In vivo canine prostates (n = 4) were treated with trisectored ultrasound transducers (3 mm OD) under MR temperature monitoring to contour the ablation zone (>52 C for 1-2 min) to the boundary of the prostate. Contiguous thermal lesions extended 2 cm in radius from the urethra in less than 15 min and independent sector control simultaneously allowed for conformal treatment in the angular dimension. Experiments investigated sequential translation of the transducer assembly within the catheter for tailoring heat treatments to different partitions in the prostate (base, apex) without changing the initial setup. This treatment method offered greater lesion shape control in three dimensions and slightly lengthened the overall treatment time. The MR temperature images correlated with post-treatment histology and accurately controlled the heating to the target boundary. MR-based control of transurethral ultrasound devices appeared more practical with multisectored transducers compared to rotating curvilinear and planar applicators due to less stringent requirements on spatial and temporal MR parameters. This study demonstrated the applicability of these devices in the prostate for anterior-lateral BPH treatment, and whole gland or quadrant target volumes for cancer treatment.

  20. Esophageal papilloma: Flexible endoscopic ablation by radiofrequency

    PubMed Central

    del Genio, Gianmattia; del Genio, Federica; Schettino, Pietro; Limongelli, Paolo; Tolone, Salvatore; Brusciano, Luigi; Avellino, Manuela; Vitiello, Chiara; Docimo, Giovanni; Pezzullo, Angelo; Docimo, Ludovico

    2015-01-01

    Squamous papilloma of the esophagus is a rare benign lesion of the esophagus. Radiofrequency ablation is an established endoscopic technique for the eradication of Barrett esophagus. No cases of endoscopic ablation of esophageal papilloma by radiofrequency ablation (RFA) have been reported. We report a case of esophageal papilloma successfully treated with a single session of radiofrequency ablation. Endoscopic ablation of the lesion was achieved by radiofrequency using a new catheter inserted through the working channel of endoscope. The esophageal ablated tissue was removed by a specifically designed cup. Complete ablation was confirmed at 3 mo by endoscopy with biopsies. This case supports feasibility and safety of as a new potential indication for BarrxTM RFA in patients with esophageal papilloma. PMID:25789102

  1. Synergistic Combination of Electrolysis and Electroporation for Tissue Ablation.

    PubMed

    Stehling, Michael K; Guenther, Enric; Mikus, Paul; Klein, Nina; Rubinsky, Liel; Rubinsky, Boris

    2016-01-01

    Electrolysis, electrochemotherapy with reversible electroporation, nanosecond pulsed electric fields and irreversible electroporation are valuable non-thermal electricity based tissue ablation technologies. This paper reports results from the first large animal study of a new non-thermal tissue ablation technology that employs "Synergistic electrolysis and electroporation" (SEE). The goal of this pre-clinical study is to expand on earlier studies with small animals and use the pig liver to establish SEE treatment parameters of clinical utility. We examined two SEE methods. One of the methods employs multiple electrochemotherapy-type reversible electroporation magnitude pulses, designed in such a way that the charge delivered during the electroporation pulses generates the electrolytic products. The second SEE method combines the delivery of a small number of electrochemotherapy magnitude electroporation pulses with a low voltage electrolysis generating DC current in three different ways. We show that both methods can produce lesion with dimensions of clinical utility, without the need to inject drugs as in electrochemotherapy, faster than with conventional electrolysis and with lower electric fields than irreversible electroporation and nanosecond pulsed ablation.

  2. Synergistic Combination of Electrolysis and Electroporation for Tissue Ablation

    PubMed Central

    Mikus, Paul; Klein, Nina; Rubinsky, Liel; Rubinsky, Boris

    2016-01-01

    Electrolysis, electrochemotherapy with reversible electroporation, nanosecond pulsed electric fields and irreversible electroporation are valuable non-thermal electricity based tissue ablation technologies. This paper reports results from the first large animal study of a new non-thermal tissue ablation technology that employs “Synergistic electrolysis and electroporation” (SEE). The goal of this pre-clinical study is to expand on earlier studies with small animals and use the pig liver to establish SEE treatment parameters of clinical utility. We examined two SEE methods. One of the methods employs multiple electrochemotherapy-type reversible electroporation magnitude pulses, designed in such a way that the charge delivered during the electroporation pulses generates the electrolytic products. The second SEE method combines the delivery of a small number of electrochemotherapy magnitude electroporation pulses with a low voltage electrolysis generating DC current in three different ways. We show that both methods can produce lesion with dimensions of clinical utility, without the need to inject drugs as in electrochemotherapy, faster than with conventional electrolysis and with lower electric fields than irreversible electroporation and nanosecond pulsed ablation. PMID:26866693

  3. [Catheter ablation of persistent atrial fibrillation : pulmonary vein isolation, ablation of fractionated electrograms, stepwise approach or rotor ablation?].

    PubMed

    Scherr, D

    2015-02-01

    Catheter ablation is an established treatment option for patients with atrial fibrillation (AF). In paroxysmal AF ablation, pulmonary vein isolation alone is a well-defined procedural endpoint, leading to success rates of up to 80% with multiple procedures over 5 years of follow-up. The success rate in persistent AF ablation is significantly more limited. This is partly due to the rudimentary understanding of the substrate maintaining persistent AF. Three main pathophysiological concepts for this arrhythmia exist: the multiple wavelet hypothesis, the concept of focal triggers, mainly located in the pulmonary veins and the rotor hypothesis. However, the targets and endpoints of persistent AF ablation are ill-defined and there is no consensus on the optimal ablation strategy in these patients. Based on these concepts, several ablation approaches for persistent AF have emerged: pulmonary vein isolation, the stepwise approach (i.e. pulmonary vein isolation, ablation of fractionated electrograms and linear ablation), magnetic resonance imaging (MRI) and rotor-based approaches. Currently, persistent AF ablation is a second-line therapy option to restore and maintain sinus rhythm. Several factors, such as the presence of structural heart disease, duration of persistent AF and dilatation and possibly also the degree of fibrosis of the left atrium should influence the decision to perform persistent AF ablation. PMID:25687615

  4. Electric Ablation with Irreversible Electroporation (IRE) in Vital Hepatic Structures and Follow-up Investigation.

    PubMed

    Chen, Xinhua; Ren, Zhigang; Zhu, Tongyin; Zhang, Xiongxin; Peng, Zhiyi; Xie, Haiyang; Zhou, Lin; Yin, Shengyong; Sun, Junhui; Zheng, Shusen

    2015-01-01

    Irreversible electroporation (IRE) with microsecond-pulsed electric fields (μsPEFs) can effectively ablate hepatocellular carcinomas in animal models. This preclinical study evaluates the feasibility and safety of IRE on porcine livers. Altogether, 10 pigs were included. Computed tomography (CT) was used to guide two-needle electrodes that were inserted near the hilus hepatis and gall bladder. Animals were followed-up at 2 hours and at 2, 7 and 14 days post-treatment. During and after μsPEF ablation, electrocardiographs found no cardiovascular events, and contrast CT found no portal vein thrombosis. There was necrosis in the ablation zone. Mild cystic oedema around the gall bladder was found 2 hours post-treatment. Pathological studies showed extensive cell death. There was no large vessel damage, but there was mild endothelial damage in some small vessels. Follow-up liver function tests and routine blood tests showed immediate liver function damage and recovery from the damage, which correlated to the pathological changes. These results indicate that μsPEF ablation affects liver tissue and is less effective in vessels, which enable μsPEFs to ablate central tumour lesions close to the hilus hepatis and near large vessels and bile ducts, removing some of the limitations and contraindications of conventional thermal ablation. PMID:26549662

  5. Planar laser-driven ablation model for nonlocalized absorption

    SciTech Connect

    Dahmani, F.; Kerdja, T. )

    1991-05-01

    A model for planar laser-driven ablation is presented. Nonlocalized inverse bremsstrahlung absorption of laser energy at a density {ital n}{sub 1}{lt}{ital n}{sub {ital c}} is assumed. A steady-state solution in the conduction zone is joined to a rarefaction wave in the underdense plasma. The calculations relate all steady-state fluid quantities to only the material, absorbed intensity, and laser wavelength. The theory agrees well with results from a computer hydrodynamics code MEDUSA (Comput. Phys. Commun. {bold 7}, 271 (1974)) and experiments.

  6. Dimension control of Superradiance

    NASA Astrophysics Data System (ADS)

    Hill, Tyler; Hui Deng Collaboration; Barry C. Sanders Collaboration

    2016-05-01

    We develop a theory for quantum dipole-dipole coupling when the electromagnetic fields are confined to an open line, open plane, or open space, commensurate with experimental capability for collective atomic effects subject to dimensional confinement. Our mathematical model naturally interpolates for all real dimension between one dimension for the line to three dimensions for open space. We show how superradiant emission can be controlled by dimensional confinement, including near-field and dipole-orientation effects, and we propose a two-dimensional confinement experiment to test our theory's efficacy. University of Michigan.

  7. Glue septal ablation: A promising alternative to alcohol septal ablation

    PubMed Central

    Aytemir, Kudret; Oto, Ali

    2016-01-01

    Hypertrophic cardiomyopathy (HCM) is defined as myocardial hypertrophy in the absence of another cardiac or systemic disease capable of producing the magnitude of present hypertrophy. In about 70% of patients with HCM, there is left ventricular outflow tract (LVOT) obstruction (LVOTO) and this is known as obstructive type of hypertrophic cardiomyopathy (HOCM). Cases refractory to medical treatment have had two options either surgical septal myectomy or alcohol septal ablation (ASA) to alleviate LVOT gradient. ASA may cause some life-threatening complications including conduction disturbances and complete heart block, hemodynamic compromise, ventricular arrhythmias, distant and massive myocardial necrosis. Glue septal ablation (GSA) is a promising technique for the treatment of HOCM. Glue seems to be superior to alcohol due to some intrinsic advantageous properties of glue such as immediate polymerization which prevents the leak into the left anterior descending coronary artery and it is particularly useful in patients with collaterals to the right coronary artery in whom alcohol ablation is contraindicated. In our experience, GSA is effective and also a safe technique without significant complications. GSA decreases LVOT gradient immediately after the procedure and this reduction persists during 12 months of follow-up. It improves New York Heart Association functional capacity and decrease interventricular septal wall thickness. Further studies are needed in order to assess the long-term efficacy and safety of this technique. PMID:27011786

  8. Dimensions of Aesthetic Perception.

    ERIC Educational Resources Information Center

    Biaggio, Mary Kay; Supplee, Katherine A.

    1983-01-01

    Examines the validity of three dimensions of aesthetic perception: hedonic value, arousal, and uncertainty. Hedonic interest and arousal factors were found to differ from factors previously reported, while the uncertainty factor paralleled that previously reported. (Author/RH)

  9. Characterization of tracked radiofrequency ablation in phantom

    SciTech Connect

    Chen, Chun-Cheng R.; Miga, Michael I.; Galloway, Robert L.

    2007-10-15

    In radiofrequency ablation (RFA), successful therapy requires accurate, image-guided placement of the ablation device in a location selected by a predictive treatment plan. Current planning methods rely on geometric models of ablations that are not sensitive to underlying physical processes in RFA. Implementing plans based on computational models of RFA with image-guided techniques, however, has not been well characterized. To study the use of computational models of RFA in planning needle placement, this work compared ablations performed with an optically tracked RFA device with corresponding models of the ablations. The calibration of the tracked device allowed the positions of distal features of the device, particularly the tips of the needle electrodes, to be determined to within 1.4{+-}0.6 mm of uncertainty. Ablations were then performed using the tracked device in a phantom system based on an agarose-albumin mixture. Images of the sliced phantom obtained from the ablation experiments were then compared with the predictions of a bioheat transfer model of RFA, which used the positional data of the tracked device obtained during ablation. The model was demonstrated to predict 90% of imaged pixels classified as being ablated. The discrepancies between model predictions and observations were analyzed and attributed to needle tracking inaccuracy as well as to uncertainties in model parameters. The results suggest the feasibility of using finite element modeling to plan ablations with predictable outcomes when implemented using tracked RFA.

  10. Picosecond and femtosecond laser ablation of hard tissues

    NASA Astrophysics Data System (ADS)

    Serafetinides, Alexander A.; Makropoulou, Mersini I.; Kar, Ajoy K.; Khabbaz, Marouan

    1996-12-01

    In this study, the interaction of picosecond and femtosecond pulsed laser radiation with human dental tissue was investigated experimentally, as this unexplored field is expected to be a potential alternative in powerful laser processing of biomedical structures. Dentin ablation rate experiments were performed by using teeth sections of different thickness. Dental tissue samples were irradiated in air with i) a regenerative amplifier laser at 1064 nm, pulse duration 110 ps, ii) the second harmonic laser at 532 nm, pulse duration 100 ps, and iii) a picosecond tunable dye amplifier at 595 nm, pulse width 800 fs. In all the experiments the pulse repetition rate was 10 Hz. The ablation rate per pulse at different energy fluence settings was calculated by measuring the time needed for the perforation of the whole dental sample thickness. Short laser pulses can confine thermal energy within the optical zone, which maximizes photothermal and photomechanical mechanisms of interaction. Tissue ablation rates were found to be comparable to or better than other nanosecond lasers, and left smooth surfaces, free of thermal damage.

  11. Optimization of Direct Current-Enhanced Radiofrequency Ablation: An Ex Vivo Study

    SciTech Connect

    Tanaka, Toshihiro Isfort, Peter; Bruners, Philipp; Penzkofer, Tobias; Kichikawa, Kimihiko; Schmitz-Rode, Thomas; Mahnken, Andreas H.

    2010-10-15

    The purpose of this study was to investigate the optimal setting for radiofrequency (RF) ablation combined with direct electrical current (DC) ablation in ex vivo bovine liver. An electrical circuit combining a commercially available RF ablation system with DC was developed. The negative electrode of a rectifier that provides DC was connected to a 3-cm multitined expandable RF probe. A 100-mH inductor was used to prevent electrical leakage from the RF generator. DC was applied for 15 min and followed by RF ablation in freshly excised bovine livers. Electric current was measured by an ammeter. Coagulation volume, ablation duration, and mean amperage were assessed for various DC voltages (no DC, 2.2, 4.5, and 9.0 V) and different RF ablation protocols (stepwise increase from 40 to 80 W, 40 W fixed, and 80 W fixed). Results were compared using Kruskal-Wallis and Mann-Whitney U test. Applying DC with 4.5 or 9.0 V, in combination with 40 W fixed or a stepwise increase of RF energy, resulted in significantly increased zone of ablation size compared with 2.2 V or no DC (P = 0.009). At 4.5 V DC, the stepwise increase of RF energy resulted in the same necrosis size as a 40 W fixed protocol (26.6 {+-} 3.9 vs. 26.5 {+-} 4.0 ml), but ablation duration was significantly decreased (296 {+-} 85 s vs. 423 {+-} 104 s; P = 0.028). Mean amperage was significantly lower at 4.5 V compared with 9.0 V (P = 0.028). Combining a stepwise increase of RF energy with a DC voltage of 4.5 V is most appropriate to increase coagulation volume and to minimize procedure time.

  12. MR Imaging to Assess Immediate Response to Irreversible Electroporation for Targeted Ablation of Liver Tissues: Preclinical Feasibility Studies in a Rodent Model1

    PubMed Central

    Zhang, Yue; Guo, Yang; Ragin, Ann B.; Lewandowski, Robert J.; Yang, Guang-Yu; Nijm, Grace M.; Sahakian, Alan V.; Omary, Reed A.

    2010-01-01

    Purpose: To test the hypothesis that magnetic resonance (MR) imaging measurements can be used to immediately detect treated tissue regions after irreversible electroporation (IRE) ablation procedures in rodent liver tissues. Materials and Methods: All experiments received institutional animal care and use committee approval. In four rats for preliminary studies and 18 rats for formal assessment, MR imaging–compatible electrodes were inserted into the liver and MR imaging–monitored IRE procedures were performed at one of three electrode voltages (1000, 1500, or 2500 V), with T1- and T2-weighted images acquired before and immediately after application of the IRE pulses. MR imaging measurements were compared with both finite element modeling (FEM)-anticipated ablation zones and histologically confirmed ablation zones at necropsy. Intraclass and Spearman correlation coefficients were calculated for statistical comparisons. Results: MR imaging measurements permitted immediate depiction of IRE ablation zones that were hypointense on T1-weighted images and hyperintense on T2-weighted images. MR imaging–based measurements demonstrated excellent consistency with FEM-anticipated ablation zones (r > 0.90 and P < .001 for both T1- and T2-weighted images). MR imaging measurements were also highly correlated with histologically confirmed ablation zone measurements (ρ > 0.90 and P < .001 for both T1- and T2-weighted images). Conclusion: MR imaging permits immediate depiction of ablated tissue zones for monitoring of IRE ablation procedures. These measurements could potentially be used during treatment to elicit repeat application of IRE pulses or adjustments to electrode positions to ensure complete treatment of targeted lesions. © RSNA, 2010 PMID:20656834

  13. The TriBeam system: Femtosecond laser ablation in situ SEM

    SciTech Connect

    Echlin, McLean P.; Straw, Marcus; Randolph, Steven; Filevich, Jorge; Pollock, Tresa M.

    2015-02-15

    Femtosecond laser ablation offers the unique ability to remove material at rates that are orders of magnitude faster than existing ion beam technologies with little or no associated damage. By combining ultrafast lasers with state-of-the-art electron microscopy equipment, we have developed a TriBeam system capable of targeted, in-situ tomography providing chemical, structural, and topographical information in three dimensions of near mm{sup 3} sized volumes. The origins, development, physics, current uses, and future potential for the TriBeam system are described in this tutorial review. - Graphical abstract: Display Omitted - Highlights: • An emerging tool, the TriBeam, for in situ femtosecond (fs) laser ablation is presented. • Fs laser ablation aided tomography at the mm{sup 3}-scale is demonstrated. • Fs laser induced deposition of Pt is demonstrated at sub-diffraction limit resolution. • Fs laser surface structuring is reviewed as well as micromachining applications.

  14. Thermo-mechanical laser ablation of soft biological tissue: modeling the micro-explosions

    NASA Astrophysics Data System (ADS)

    Majaron, B.; Plestenjak, P.; Lukač, M.

    Characteristics of thermo-mechanical laser ablation process are investigated using an original numerical model. In contrast with previous models, it is based on a microscopic physical model of the micro-explosion process, which combines thermodynamic behavior of tissue water with elastic response of the solid tissue components. Diffusion of dissipated heat is treated in one dimension, and the amount of thermal damage is assessed using the Arrhenius model of the protein denaturation kinetics. Influence of the pulse fluence and duration on temperature profile development, ablation threshold, and depth of thermal damage is analyzed for the case of Er:YAG laser irradiation of human skin. Influence of mechanical properties on the ablation threshold of soft tissue is predicted theoretically for the first time. In addition, feasibility of deep tissue coagulation with a repetitively pulsed Er:YAG laser is indicated from the model.

  15. Nanometer-scale ablation using focused, coherent extreme ultraviolet/soft x-ray light

    DOEpatents

    Menoni, Carmen S.; Rocca, Jorge J.; Vaschenko, Georgiy; Bloom, Scott; Anderson, Erik H.; Chao, Weilun; Hemberg, Oscar

    2011-04-26

    Ablation of holes having diameters as small as 82 nm and having clean walls was obtained in a poly(methyl methacrylate) on a silicon substrate by focusing pulses from a Ne-like Ar, 46.9 nm wavelength, capillary-discharge laser using a freestanding Fresnel zone plate diffracting into third order is described. Spectroscopic analysis of light from the ablation has also been performed. These results demonstrate the use of focused coherent EUV/SXR light for the direct nanoscale patterning of materials.

  16. Development of a Laser Ablation ICPMS Rutile Standard

    NASA Astrophysics Data System (ADS)

    Lytle, M. L.; Kohn, M. J.

    2015-12-01

    Rutile is a common accessory mineral in igneous and high-grade metamorphic rocks and igneous, with many applications in geosciences. Rutile geochemistry, especially the high field strength elements (i.e., Nb and Ta), monitors many geological processes including subduction-zone metamorphism, while Zr provides temperature information in buffering assemblages. Rutile can also be used for U-Pb geochronology, but typically low U concentrations can make age dating difficult. Many applications of rutile now rely on laser ablation ICPMS (LA-ICPMS) analysis, a major disadvantage of this technique is the lack of reliable rutile standards. Here, we present laser ablation data of several rutile megacrysts from around the world, illustrating typical geochemical characteristics of potential standards. Whole-grain transects and depth profiles were collected on several rutiles, including Graves Mountain, Kragerø, Madagascar, Mozambique, Quebec, and Diamantina. Most transects, particularly across Graves Mountain and Diamantina, show dramatic zoning in Zr (up to 100 ppm), U (up to 10 ppm), and Nb (up to 1000 ppm). Rutile grains from Mozambique and Kragerø show little variation in concentration in Zr, U, and Nb. However, U concentrations generally range from 1ppm (Graves Mountain) to 45ppm (Kragero). Depth profiles (30-80s analysis; 15-40 μm) showed a combination of slight surface contamination plus minor to significant near-rim zoning. Some samples, such as Mozambique, show minor concentration changes in Zr, Nb, and Ta over the outer 10 μm but are otherwise unzoned, whereas U concentrations decrease for 25 μm then are constant. Kragero shows depth zoning throughout for Zr, Ta, and U but Nb is unzoned. Some rutile megacrysts show promise as standards (e.g. Mozambique and Kragero), but must be prepared to eliminate crystal surfaces. Other megacrysts would have to be subsampled within specific crystals to isolate chemical homogeneous domains.

  17. Formulating a coastal zone health metric for landuse impact management in urban coastal zones.

    PubMed

    Anilkumar, P P; Varghese, Koshy; Ganesh, L S

    2010-11-01

    The need for ICZM arises often due to inadequate or inappropriate landuse planning practices and policies, especially in urban coastal zones which are more complex due to the larger number of components, their critical dimensions, attributes and interactions. A survey of literature shows that there is no holistic metric for assessing the impacts of landuse planning on the health of a coastal zone. Thus there is a need to define such a metric. The proposed metric, CHI (Coastal zone Health Indicator), developed on the basis of coastal system sustainability, attempts to gauge the health status of any coastal zone. It is formulated and modeled through an expert survey and pertains to the characteristic components of coastal zones, their critical dimensions, and relevant attributes. The proposed metric is applied to two urban coastal zones and validated. It can be used for more coast friendly and sustainable landuse planning/masterplan preparation and thereby for the better management of landuse impacts on coastal zones.

  18. Selective Attention to Perceptual Dimensions and Switching between Dimensions

    ERIC Educational Resources Information Center

    Meiran, Nachshon; Dimov, Eduard; Ganel, Tzvi

    2013-01-01

    In the present experiments, the question being addressed was whether switching attention between perceptual dimensions and selective attention to dimensions are processes that compete over a common resource? Attention to perceptual dimensions is usually studied by requiring participants to ignore a never-relevant dimension. Selection failure…

  19. Production of microscale particles from fish bone by gas flow assisted laser ablation

    NASA Astrophysics Data System (ADS)

    Boutinguiza, M.; Lusquiños, F.; Comesaña, R.; Riveiro, A.; Quintero, F.; Pou, J.

    2007-12-01

    Recycled wastes from fish and seafood can constitute a source of precursor material for different applications in the biomedical field such as bone fillers or precursor material for bioceramic coatings to improve the osteointegration of metallic implants. In this work, fish bones have been used directly as target in a laser ablation system. A pulsed Nd:YAG laser was used to ablate the fish bone material and a transverse air flow was used to extract the ablated material out of the interaction zone. The particles collected at a filter were in the micro and nanoscale range. The morphology as well as the composition of the obtained particles were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and transmission electron microscopy (TEM). The results reveal that the composition of the analyzed particles is similar to that of the inorganic part of the fish bone.

  20. Extra Dimensions of Space

    ERIC Educational Resources Information Center

    Lincoln, Don

    2013-01-01

    They say that there is no such thing as a stupid question. In a pedagogically pure sense, that's probably true. But some questions do seem to flirt dangerously close to being really quite ridiculous. One such question might well be, "How many dimensions of space are there?" I mean, it's pretty obvious that there are three:…

  1. Dimensions of Delinquency.

    ERIC Educational Resources Information Center

    Wunderlich, Richard A.

    1985-01-01

    In response to research questioning the utility of the Jesness Inventory in predicting and differentiating delinquency, this study isolated the personality dimensions of 422 adjudicated, noninstitutionalized adolescents by item level factor analysis. The resulting three factors--Mistrust, Social Pessimism, and Hypersensitivity--were compared with…

  2. Moving between Dimensions

    ERIC Educational Resources Information Center

    Stephenson, Paul

    2012-01-01

    The first word of this item is "imagine". This instruction has the potential to signal a journey through a world of geometry that might leave you spellbound. On the other hand, it could be the start of a roller-coaster ride through three dimensions that will tax both your imagination, and your powers of visualisation. It is likely that you will…

  3. Big Mysteries: Extra Dimensions

    SciTech Connect

    Lincoln, Don

    2014-06-10

    The weakness of gravity compared to the other subatomic forces is a real mystery. While nobody knows the answer, one credible solution is that gravity has access to more spatial dimensions than the other three known forces. In this video, Fermilab's Dr. Don Lincoln describes this idea, with the help of some very urbane characters.

  4. Dimensions of Nonverbal Communication.

    ERIC Educational Resources Information Center

    Overmier, Mary; And Others

    After a brief description of the dimensions of nonverbal communication, this booklet presents 21 activities that deal with nonverbal communication. Activities in the booklet involve body movements (kinesics), facial expressions, eye movements, perception and use of space (proxemics), haptics (touch), paralinguistics (vocal elements that accompany…

  5. Big Mysteries: Extra Dimensions

    ScienceCinema

    Lincoln, Don

    2016-07-12

    The weakness of gravity compared to the other subatomic forces is a real mystery. While nobody knows the answer, one credible solution is that gravity has access to more spatial dimensions than the other three known forces. In this video, Fermilab's Dr. Don Lincoln describes this idea, with the help of some very urbane characters.

  6. Physics in One Dimension

    ERIC Educational Resources Information Center

    Bertel, Erminald

    2013-01-01

    Due to progress in nanotechnology high-quality quantum wires can nowadays be fabricated. The behavior of particles in one dimension differs significantly from that in three-dimensional (3D) systems, yet the physics of such low-dimensional systems is generally not very well represented in standard undergraduate or graduate curricula. For instance,…

  7. Possible role for cryoballoon ablation of right atrial appendage tachycardia when conventional ablation fails.

    PubMed

    Amasyali, Basri; Kilic, Ayhan

    2015-06-01

    Focal atrial tachycardia arising from the right atrial appendage usually responds well to radiofrequency ablation; however, successful ablation in this anatomic region can be challenging. Surgical excision of the right atrial appendage has sometimes been necessary to eliminate the tachycardia and prevent or reverse the resultant cardiomyopathy. We report the case of a 48-year-old man who had right atrial appendage tachycardia resistant to multiple attempts at ablation with use of conventional radiofrequency energy guided by means of a 3-dimensional mapping system. The condition led to cardiomyopathy in 3 months. The arrhythmia was successfully ablated with use of a 28-mm cryoballoon catheter that had originally been developed for catheter ablation of paroxysmal atrial fibrillation. To our knowledge, this is the first report of cryoballoon ablation without isolation of the right atrial appendage. It might also be an alternative to epicardial ablation or surgery when refractory atrial tachycardia originates from the right atrial appendage.

  8. Picosecond laser ablation system with process control by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Targowski, Piotr; Ostrowski, Roman; Marczak, Jan; Sylwestrzak, Marcin; Kwiatkowska, Ewa A.

    2009-07-01

    In this contribution we describe an apparatus for precise laser ablation of delicate layers, like varnish on pictures. This specific case is very demanding. First of all any changes in colour of remaining varnish layer as well as underneath paint layers are unacceptable. This effect may be induced photochemically or thermically. In the first case strong absorption of the radiation used will eliminate its influence on underlying strata. The thermal effect is limited to so called heat affected zone (HAZ). In addition to colour change, a mechanical damage caused by overheating of the structure adjacent to ablated region should be considered also. All kinds of treads must be carefully eliminated in order to make laser ablation of varnish commonly accepted alternative to chemical and/or mechanical treatments [1]. Since the varnish ablation process is obviously irreversible its effective monitoring is very important to make it safe and trusted. As we showed previously [2-6] optical coherence tomography (OCT) originated from medicine diagnostic method for examination and imaging of cross-sections of weakly absorbing objects can be used for this task. OCT utilises infrared light for non-invasive structure examination and has been under consideration for the examining of objects of art since 2004 [7-10]. In this case the in-depth (axial) resolution is obtained by means of interference of light of high spatial (to ensure sensitivity) and very low temporal coherence (to ensure high axial resolution). In practice, IR sources of bandwidths from 25 to 150 nm are utilised. Resolutions obtained range from 15 down to 2 μm in the media of refracting index equal 1.5. In this contribution we expand application of OCT to space resolved determination of ablation rates, separately for every point of examined area. Such data help in better understanding of the ablation process, fine tuning the laser and finally permit increase of the safety of the ablation process.

  9. Lung Radiofrequency Ablation: In Vivo Experimental Study with Low-Perfusion-Rate Multitined Electrodes

    SciTech Connect

    Crocetti, Laura Lencioni, Riccardo; Bozzi, Elena; Sbrana, Alberto; Bartolozzi, Carlo

    2008-05-15

    The purpose of this study was to investigate the feasibility and safety of lung radiofrequency (RF) ablation by using low-perfusion-rate, expandable, multitined electrodes in an in vivo animal model. Ten New Zealand White rabbits underwent RF ablation using low-perfusion-rate, expandable, multitined electrodes (Starburst Talon; RITA Medical Systems, Mountain View, CA) and a 200-W RF generator. The electrode was positioned under fluoroscopy guidance and a single percutaneous RF ablation was performed. Saline perfusate was doped with nonionic iodinated contrast agent to render it visible on computed tomography (CT). The pump infused the saline doped with contrast agent into the lateral tines at a rate of 0.1ml/min. The planned ablation was of 3 min, with the hooks deployed to 2 cm at a target temperature of 105{sup o}C. An immediate posttreatment CT scan documented the distribution of the doped saline and the presence of immediate complications. The animals were monitored for delayed complications and sacrificed within 72 h (n = 4), 2 weeks (n = 3), or 4 weeks (n = 3). Assessment of ablation zone and adjacent structures was done at autopsy. Major complications consisted of pneumothorax requiring drainage (n = 2) and skin burn (n = 1). Immediately after the procedure the area of ablation was depicted at CT as a round, well-demarcated area, homogeneously opacified by iodinated contrast medium (mean size, 2.3 {+-} 0.8 cm). The presence of a sharply demarcated area of coagulation necrosis (mean size, 2.1 {+-} 0.4 cm) without severe damage to adjacent structures was confirmed at autopsy. In one case, euthanized at 4 weeks, in whom pneumothorax and pleural effusion were depicted, pleural fibrinous adhesions were demonstrated at autopsy. In conclusion, lung RF ablation performed in an in vivo animal model using low-perfusion-rate, expandable, multitined electrodes is feasible and safe. No severe damage to adjacent structures was demonstrated.

  10. Testing and evaluation of light ablation decontamination

    SciTech Connect

    Demmer, R.L.; Ferguson, R.L.

    1994-10-01

    This report details the testing and evaluation of light ablation decontamination. It details WINCO contracted research and application of light ablation efforts by Ames Laboratory. Tests were conducted with SIMCON (simulated contamination) coupons and REALCON (actual radioactive metal coupons) under controlled conditions to compare cleaning effectiveness, speed and application to plant process type equipment.

  11. Image-Guided Radiofrequency Ablation (RFA) of Unresectable Hepatic Tumors Using a Triple-Spiral-Shaped Electrode Needle: Initial Experience in 34 Patients

    SciTech Connect

    Thanos, Loukas; Poulou, Loukia S.; Ziakas, Panayiotis D.; Kelekis, Alexis D.; Pomoni, Maria; Kelekis, Dimitrios A.

    2010-02-15

    We evaluated the safety and efficacy of image-guided radiofrequency ablation (RFA) using a triple-spiral-shaped electrode needle for unresectable primary or metastatic hepatic tumors. Thirty-four patients with 46 index tumors were treated. Ablation zone, morbidity, and complications were assessed. The lesions were completely ablated with an ablative margin of about 1 cm. Five patients (14.7%) with a lesion larger than 4.5 cm had local tumor progression after 1 month and were retreated. Hemothorax, as a major complication, occurred in 1 of 34 patients (3.0%) or 1 of 46 lesions ablated (2.2%). RFA using this new electrode needle can be effective in the treatment of large unresectable hepatic tumors.

  12. Efficacy and predictability of soft tissue ablation using a prototype Raman-shifted alexandrite laser.

    PubMed

    Kozub, John A; Shen, Jin-H; Joos, Karen M; Prasad, Ratna; Hutson, M Shane

    2015-10-01

    Previous research showed that mid-infrared free-electron lasers could reproducibly ablate soft tissue with little collateral damage. The potential for surgical applications motivated searches for alternative tabletop lasers providing thermally confined pulses in the 6- to-7-µm wavelength range with sufficient pulse energy, stability, and reliability. Here, we evaluate a prototype Raman-shifted alexandrite laser. We measure ablation thresholds, etch rates, and collateral damage in gelatin and cornea as a function of laser wavelength (6.09, 6.27, or 6.43 µm), pulse energy (up to 3 mJ/pulse), and spot diameter (100 to 600 µm). We find modest wavelength dependence for ablation thresholds and collateral damage, with the lowest thresholds and least damage for 6.09 µm. We find a strong spot-size dependence for all metrics. When the beam is tightly focused (~100-µm diameter), ablation requires more energy, is highly variable and less efficient, and can yield large zones of mechanical damage (for pulse energies>1 mJ). When the beam is softly focused (~300-µm diameter), ablation proceeded at surgically relevant etch rates, with reasonable reproducibility (5% to 12% within a single sample), and little collateral damage. With improvements in pulse-energy stability, this prototype laser may have significant potential for soft-tissue surgical applications.

  13. Efficacy and predictability of soft tissue ablation using a prototype Raman-shifted alexandrite laser

    PubMed Central

    Kozub, John A.; Shen, Jin-H.; Joos, Karen M.; Prasad, Ratna; Shane Hutson, M.

    2015-01-01

    Abstract. Previous research showed that mid-infrared free-electron lasers could reproducibly ablate soft tissue with little collateral damage. The potential for surgical applications motivated searches for alternative tabletop lasers providing thermally confined pulses in the 6- to-7-μm wavelength range with sufficient pulse energy, stability, and reliability. Here, we evaluate a prototype Raman-shifted alexandrite laser. We measure ablation thresholds, etch rates, and collateral damage in gelatin and cornea as a function of laser wavelength (6.09, 6.27, or 6.43  μm), pulse energy (up to 3  mJ/pulse), and spot diameter (100 to 600  μm). We find modest wavelength dependence for ablation thresholds and collateral damage, with the lowest thresholds and least damage for 6.09  μm. We find a strong spot-size dependence for all metrics. When the beam is tightly focused (∼100-μm diameter), ablation requires more energy, is highly variable and less efficient, and can yield large zones of mechanical damage (for pulse energies >1  mJ). When the beam is softly focused (∼300-μm diameter), ablation proceeded at surgically relevant etch rates, with reasonable reproducibility (5% to 12% within a single sample), and little collateral damage. With improvements in pulse-energy stability, this prototype laser may have significant potential for soft-tissue surgical applications. PMID:26456553

  14. Efficacy and predictability of soft tissue ablation using a prototype Raman-shifted alexandrite laser

    NASA Astrophysics Data System (ADS)

    Kozub, John A.; Shen, Jin-H.; Joos, Karen M.; Prasad, Ratna; Shane Hutson, M.

    2015-10-01

    Previous research showed that mid-infrared free-electron lasers could reproducibly ablate soft tissue with little collateral damage. The potential for surgical applications motivated searches for alternative tabletop lasers providing thermally confined pulses in the 6- to-7-μm wavelength range with sufficient pulse energy, stability, and reliability. Here, we evaluate a prototype Raman-shifted alexandrite laser. We measure ablation thresholds, etch rates, and collateral damage in gelatin and cornea as a function of laser wavelength (6.09, 6.27, or 6.43 μm), pulse energy (up to 3 mJ/pulse), and spot diameter (100 to 600 μm). We find modest wavelength dependence for ablation thresholds and collateral damage, with the lowest thresholds and least damage for 6.09 μm. We find a strong spot-size dependence for all metrics. When the beam is tightly focused (˜100-μm diameter), ablation requires more energy, is highly variable and less efficient, and can yield large zones of mechanical damage (for pulse energies >1 mJ). When the beam is softly focused (˜300-μm diameter), ablation proceeded at surgically relevant etch rates, with reasonable reproducibility (5% to 12% within a single sample), and little collateral damage. With improvements in pulse-energy stability, this prototype laser may have significant potential for soft-tissue surgical applications.

  15. Efficacy and predictability of soft tissue ablation using a prototype Raman-shifted alexandrite laser.

    PubMed

    Kozub, John A; Shen, Jin-H; Joos, Karen M; Prasad, Ratna; Hutson, M Shane

    2015-10-01

    Previous research showed that mid-infrared free-electron lasers could reproducibly ablate soft tissue with little collateral damage. The potential for surgical applications motivated searches for alternative tabletop lasers providing thermally confined pulses in the 6- to-7-µm wavelength range with sufficient pulse energy, stability, and reliability. Here, we evaluate a prototype Raman-shifted alexandrite laser. We measure ablation thresholds, etch rates, and collateral damage in gelatin and cornea as a function of laser wavelength (6.09, 6.27, or 6.43 µm), pulse energy (up to 3 mJ/pulse), and spot diameter (100 to 600 µm). We find modest wavelength dependence for ablation thresholds and collateral damage, with the lowest thresholds and least damage for 6.09 µm. We find a strong spot-size dependence for all metrics. When the beam is tightly focused (~100-µm diameter), ablation requires more energy, is highly variable and less efficient, and can yield large zones of mechanical damage (for pulse energies>1 mJ). When the beam is softly focused (~300-µm diameter), ablation proceeded at surgically relevant etch rates, with reasonable reproducibility (5% to 12% within a single sample), and little collateral damage. With improvements in pulse-energy stability, this prototype laser may have significant potential for soft-tissue surgical applications. PMID:26456553

  16. Lung Cancer Ablation: Technologies and Techniques

    PubMed Central

    Alexander, Erica S.; Dupuy, Damian E.

    2013-01-01

    The incidence of lung cancers in 2012 is estimated to reach 226,160 new cases, with only a third of patients suitable surgical candidates. Tumor ablation has emerged as an important and efficacious treatment option for nonsurgical lung cancer patients. This localized minimally invasive therapy is best suited for small oligonodular lesions or favorably located metastatic tumors. Radiofrequency ablation has been in use for over a decade, and newer modalities including microwave ablation, cryoablation, and irreversible electroporation have emerged as additional treatment options for patients. Ablation therapies can offer patients and clinicians a repeatable and effective therapy for palliation and, in some cases, cure of thoracic malignancies. This article discusses the available technologies and techniques available for tumor ablation of thoracic malignancies including patient selection, basic aspects of procedure technique, imaging follow-up, treatment outcomes, and comparisons between various therapies. PMID:24436530

  17. Ablative shielding for hypervelocity projectiles

    NASA Technical Reports Server (NTRS)

    Rucker, Michelle A. (Inventor)

    1993-01-01

    A hypervelocity projectile shield which includes a hollow semi-flexible housing fabricated from a plastic like, or otherwise transparent membrane which is filled with a fluid (gas or liquid) is presented. The housing has a inlet valve, similar to that on a tire or basketball, to introduce an ablating fluid into the housing. The housing is attached by a Velcro mount or double-sided adhesive tape to the outside surface of a structure to be protected. The housings are arrayed in a side-by-side relationship for complete coverage of the surface to be protected. In use, when a hypervelocity projectile penetrates the outer wall of a housing it is broken up and then the projectile is ablated as it travels through the fluid, much like a meteorite 'burns up' as it enters the earth's atmosphere, and the housing is deflated. The deflated housing can be easily spotted for replacement, even from a distance. Replacement is then accomplished by simply pulling a deflated housing off the structure and installing a new housing.

  18. Influence of the embryonic preplate on the organization of the cerebral cortex: a targeted ablation model.

    PubMed

    Xie, Y; Skinner, E; Landry, C; Handley, V; Schonmann, V; Jacobs, E; Fisher, R; Campagnoni, A

    2002-10-15

    Transgenic mice were generated to permit the targeted ablation of cortical preplate cells at the time they are born. In these mice, the 1.3 kb golli promoter of the myelin basic protein gene was used to drive the herpes simplex virus thymidine kinase (TK) transgene in cortical preplate cells. Heterozygous transgenic pairs were bred, and pregnant dams were treated with ganciclovir at embryonic days 11-12 to ablate preplate cells at the time the preplate was forming. This paradigm exposed control (TK-) and experimental (TK+) littermates to exactly the same conditions. Embryological ablation of preplate cells led to an early disruption of the radial glial framework and subplate structure in the developing cortex and dramatically altered the cellular lamination and connectivity of the cortical plate. The disturbed radial glial network contributed to an impaired radial migration of neurons into the cortical plate from the ventricular zone. The cortical plate became dyslaminated, and there was a substantial reduction in short- and long-range cortical projections within the cortex and to subcortical regions. Cell death within the cortical plate and the proliferative zones was substantially increased in the ablated animals. After birth, a cortical lesion developed, which became exacerbated with the secondary onset of hydrocephaly in the second postnatal week. The results underscore the critical importance of the preplate in cortex formation, mediated through its guidance of the formation of radial glial scaffolding, subsequent neuronal migration into the incipient cortical plate, and the final arrangement of its vertical organization and cellular connectivity.

  19. Feasibility of Extracted-Overlay Fusion Imaging for Intraoperative Treatment Evaluation of Radiofrequency Ablation for Hepatocellular Carcinoma

    PubMed Central

    Makino, Yuki; Imai, Yasuharu; Igura, Takumi; Kogita, Sachiyo; Sawai, Yoshiyuki; Fukuda, Kazuto; Iwamoto, Takayuki; Okabe, Junya; Takamura, Manabu; Fujita, Norihiko; Hori, Masatoshi; Takehara, Tetsuo; Kudo, Masatoshi; Murakami, Takamichi

    2016-01-01

    Background and Aims Extracted-overlay fusion imaging is a novel computed tomography/magnetic resonance-ultrasonography (CT/MR-US) imaging technique in which a target tumor with a virtual ablative margin is extracted from CT/MR volume data and synchronously overlaid on US images. We investigated the applicability of the technique to intraoperative evaluation of radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC). Methods This retrospective study analyzed 85 HCCs treated with RFA using extracted-overlay fusion imaging for guidance and evaluation. To perform RFA, an electrode was inserted targeting the tumor and a virtual 5-mm ablative margin overlaid on the US image. Following ablation, contrast-enhanced US (CEUS) was performed to assess the ablative margin, and the minimal ablative margins were categorized into three groups: (I) margin <0 mm (protrusion), (II) margin 0 to <5 mm, and (III) margin ≥5 mm. Margin assessment was based on the positional relationship between the overlaid tumor plus margin and the perfusion defect of the ablation zone. Tumors in group I underwent repeat ablation until they were in groups II or III. The final classifications were compared with those obtained by retrospectively created fusion images of pre- and post-RFA CT or MR imaging (CT-CT/MR-MR fusion imaging). Results Treatment evaluation was impossible using CEUS in six HCCs because the tumors were located far below the body surface. Of the remaining 79 HCCs, the categorizations of minimal ablative margins between CEUS extracted-overlay fusion imaging and CT-CT/MR-MR fusion imaging were in agreement for 72 tumors (91.1%) (Cohen's quadratic-weighted kappa coefficient 0.66, good agreement, p<0.01). Conclusions Extracted-overlay fusion imaging combined with CEUS is feasible for the evaluation of RFA and enables intraoperative treatment evaluation without the need to perform contrast-enhanced CT. PMID:27781199

  20. Tensor sufficient dimension reduction

    PubMed Central

    Zhong, Wenxuan; Xing, Xin; Suslick, Kenneth

    2015-01-01

    Tensor is a multiway array. With the rapid development of science and technology in the past decades, large amount of tensor observations are routinely collected, processed, and stored in many scientific researches and commercial activities nowadays. The colorimetric sensor array (CSA) data is such an example. Driven by the need to address data analysis challenges that arise in CSA data, we propose a tensor dimension reduction model, a model assuming the nonlinear dependence between a response and a projection of all the tensor predictors. The tensor dimension reduction models are estimated in a sequential iterative fashion. The proposed method is applied to a CSA data collected for 150 pathogenic bacteria coming from 10 bacterial species and 14 bacteria from one control species. Empirical performance demonstrates that our proposed method can greatly improve the sensitivity and specificity of the CSA technique. PMID:26594304

  1. Cultural dimensions of learning

    NASA Astrophysics Data System (ADS)

    Eyford, Glen A.

    1990-06-01

    How, what, when and where we learn is frequently discussed, as are content versus process, or right brain versus left brain learning. What is usually missing is the cultural dimension. This is not an easy concept to define, but various aspects can be identified. The World Decade for Cultural Development emphasizes the need for a counterbalance to a quantitative, economic approach. In the last century poets also warned against brutalizing materialism, and Sorokin and others have described culture more recently in terms of cohesive basic values expressed through aesthetics and institutions. Bloom's taxonomy incorporates the category of affective learning, which internalizes values. If cultural learning goes beyond knowledge acquisition, perhaps the surest way of understanding the cultural dimension of learning is to examine the aesthetic experience. This can use myths, metaphors and symbols, and to teach and learn by using these can help to unlock the human potential for vision and creativity.

  2. Infinitely Large New Dimensions

    SciTech Connect

    Arkani-Hamed, Nima; Dimopoulos, Savas; Dvali, Gia; Kaloper, Nemanja

    1999-07-29

    We construct intersecting brane configurations in Anti-de-Sitter space localizing gravity to the intersection region, with any number n of extra dimensions. This allows us to construct two kinds of theories with infinitely large new dimensions, TeV scale quantum gravity and sub-millimeter deviations from Newton's Law. The effective 4D Planck scale M{sub Pl} is determined in terms of the fundamental Planck scale M{sub *} and the AdS radius of curvature L via the familiar relation M{sub Pl}{sup 2} {approx} M{sub *}{sup 2+n} L{sup n}; L acts as an effective radius of compactification for gravity on the intersection. Taking M{sub *} {approx} TeV and L {approx} sub-mm reproduces the phenomenology of theories with large extra dimensions. Alternately, taking M{sub *} {approx} L{sup -1} {approx} M{sub Pl}, and placing our 3-brane a distance {approx} 100M{sub Pl}{sup -1} away from the intersection gives us a theory with an exponential determination of the Weak/Planck hierarchy.

  3. On the Ablation Models of Fuel Pellets

    SciTech Connect

    Rozhansky, V.A.; Senichenkov, I.Yu.

    2005-12-15

    The neutral gas shielding model and neutral-gas-plasma shielding model are analyzed qualitatively. The main physical processes that govern the formation of the shielding gas cloud and, consequently, the ablation rate are considered. For the neutral gas shielding model, simple formulas relating the ablation rate and cloud parameters to the parameters of the pellet and the background plasma are presented. The estimates of the efficiency of neutral gas shielding and plasma shielding are compared. It is shown that the main portion of the energy flux of the background electrons is released in the plasma cloud. Formulas for the ablation rate and plasma parameters are derived in the neutral-gas-plasma shielding model. The question is discussed as to why the neutral gas shielding model describes well the ablation rate of the pellet material, although it does not take into account the ionization effects and the effects associated with the interaction of ionized particles with the magnetic field. The reason is that the ablation rate depends weakly on the energy flux of hot electrons; as a result, the attenuation of this flux by the electrostatic shielding and plasma shielding has little effect on the ablation rate. This justifies the use of the neutral gas shielding model to estimate the ablation rate (to within a factor of about 2) over a wide range of parameters of the pellet and the background plasma.

  4. Dynamics of mid-infrared femtosecond laser resonant ablation

    NASA Astrophysics Data System (ADS)

    Pang, Dongqing; Li, Yunxuan; Wang, Qingyue

    2014-06-01

    Resonant ablation is beneficial to avoiding uncontrollable subsurface damages in the laser ablation of polymers. In this paper the dynamics of mid-infrared laser resonant ablation of polylactic acid and toluene was calculated by using fluid dynamic equations. The merits and drawbacks of mid-infrared femtosecond laser resonant ablation of high molecular weight polymers have been discussed.

  5. Pulsed and CW adjustable 1942 nm single-mode all-fiber Tm-doped fiber laser system for surgical laser soft tissue ablation applications.

    PubMed

    Huang, Yize; Jivraj, Jamil; Zhou, Jiaqi; Ramjist, Joel; Wong, Ronnie; Gu, Xijia; Yang, Victor X D

    2016-07-25

    A surgical laser soft tissue ablation system based on an adjustable 1942 nm single-mode all-fiber Tm-doped fiber laser operating in pulsed or CW mode with nitrogen assistance is demonstrated. Ex vivo ablation on soft tissue targets such as muscle (chicken breast) and spinal cord (porcine) with intact dura are performed at different ablation conditions to examine the relationship between the system parameters and ablation outcomes. The maximum laser average power is 14.4 W, and its maximum peak power is 133.1 W with 21.3 μJ pulse energy. The maximum CW power density is 2.33 × 106 W/cm2 and the maximum pulsed peak power density is 2.16 × 107 W/cm2. The system parameters examined include the average laser power in CW or pulsed operation mode, gain-switching frequency, total ablation exposure time, and the input gas flow rate. The ablation effects were measured by microscopy and optical coherence tomography (OCT) to evaluate the ablation depth, superficial heat-affected zone diameter (HAZD) and charring diameter (CD). Our results conclude that the system parameters can be tailored to meet different clinical requirements such as ablation for soft tissue cutting or thermal coagulation for future applications of hemostasis. PMID:27464121

  6. Real-time conductivity imaging of temperature and tissue property changes during radiofrequency ablation: an ex vivo model using weighted frequency difference.

    PubMed

    Wi, Hun; McEwan, Alistair Lee; Lam, Vincent; Kim, Hyung Joong; Woo, Eung Je; Oh, Tong In

    2015-04-01

    We demonstrated the feasibility of time difference and weighted frequency difference conductivity imaging for real-time monitoring of temperature distribution and ablation region estimation during radiofrequency (RF) ablation. The electrical conductivity spectrum of biological tissue reflects mobility of ions in intra- and extra-cellular fluids and changes in cellular morphology induced by heating. The time series conductivity spectra were measured in an ex vivo bovine liver by a high-speed electrical impedance tomography (EIT) system. The EIT system was protected by filters to suppress RF energy and allow interleaved real-time imaging. We recorded time and weighted frequency-difference conductivity images and direct temperature variations at the ablation region and control region during 8 min ablation and for the following 66 min of cooling. Conductivity variation in regions of interest was compared with temperature recordings. Contours of conductivity change were visualized and compared to estimate the ablation area. EIT images confirmed increase of conductivity at all frequencies and loss of frequency conductivity change associated with loss of cellular structure. Time difference conductivity images showed changes due to both heating during ablation and heat dissipation following ablation together with tissue property changes. Weighted frequency-difference images presented persistent changes following heating due to the morphological change in the ablation zone.

  7. Pulsed and CW adjustable 1942 nm single-mode all-fiber Tm-doped fiber laser system for surgical laser soft tissue ablation applications.

    PubMed

    Huang, Yize; Jivraj, Jamil; Zhou, Jiaqi; Ramjist, Joel; Wong, Ronnie; Gu, Xijia; Yang, Victor X D

    2016-07-25

    A surgical laser soft tissue ablation system based on an adjustable 1942 nm single-mode all-fiber Tm-doped fiber laser operating in pulsed or CW mode with nitrogen assistance is demonstrated. Ex vivo ablation on soft tissue targets such as muscle (chicken breast) and spinal cord (porcine) with intact dura are performed at different ablation conditions to examine the relationship between the system parameters and ablation outcomes. The maximum laser average power is 14.4 W, and its maximum peak power is 133.1 W with 21.3 μJ pulse energy. The maximum CW power density is 2.33 × 106 W/cm2 and the maximum pulsed peak power density is 2.16 × 107 W/cm2. The system parameters examined include the average laser power in CW or pulsed operation mode, gain-switching frequency, total ablation exposure time, and the input gas flow rate. The ablation effects were measured by microscopy and optical coherence tomography (OCT) to evaluate the ablation depth, superficial heat-affected zone diameter (HAZD) and charring diameter (CD). Our results conclude that the system parameters can be tailored to meet different clinical requirements such as ablation for soft tissue cutting or thermal coagulation for future applications of hemostasis.

  8. Thermal protection system ablation sensor

    NASA Technical Reports Server (NTRS)

    Gorbunov, Sergey (Inventor); Martinez, Edward R. (Inventor); Scott, James B. (Inventor); Oishi, Tomomi (Inventor); Fu, Johnny (Inventor); Mach, Joseph G. (Inventor); Santos, Jose B. (Inventor)

    2011-01-01

    An isotherm sensor tracks space vehicle temperatures by a thermal protection system (TPS) material during vehicle re-entry as a function of time, and surface recession through calibration, calculation, analysis and exposed surface modeling. Sensor design includes: two resistive conductors, wound around a tube, with a first end of each conductor connected to a constant current source, and second ends electrically insulated from each other by a selected material that becomes an electrically conductive char at higher temperatures to thereby complete an electrical circuit. The sensor conductors become shorter as ablation proceeds and reduced resistance in the completed electrical circuit (proportional to conductor length) is continually monitored, using measured end-to-end voltage change or current in the circuit. Thermocouple and/or piezoelectric measurements provide consistency checks on local temperatures.

  9. Laser-Ablation (U-Th)/He Geochronology

    NASA Astrophysics Data System (ADS)

    Hodges, K.; Boyce, J.

    2003-12-01

    Over the past decade, ultraviolet laser microprobes have revolutionized the field of 40Ar/39Ar geochronology. They provide unprecedented information about Ar isotopic zoning in natural crystals, permit high-resolution characterization of Ar diffusion profiles produced during laboratory experiments, and enable targeted dating of multiple generations of minerals in thin section. We have modified the analytical protocols used for 40Ar/39Ar laser microanalysis for use in (U-Th)/He geochronologic studies. Part of the success of the 40Ar/39Ar laser microprobe stems from fact that measurements of Ar isotopic ratios alone are sufficient for the calculation of a date. In contrast, the (U-Th)/He method requires separate analysis of U+Th and 4He. Our method employs two separate laser microprobes for this process. A target mineral grain is placed in an ultrahigh vacuum chamber fitted with a window of appropriate composition to transmit ultraviolet radiation. A focused ArF (193 nm) excimer laser is used to ablate tapered cylindrical pits on the surface of the target. The liberated material is scrubbed with a series of getters in a fashion similar to that used for 40Ar/39Ar geochronology, and the 4He abundance is determined using a quadrupole mass spectrometer with well-calibrated sensitivity. A key requirement for calculation of the 4He abundance in the target is a precise knowledge of the volume of the ablation pit. This is the principal reason why we employ the ArF excimer for 4He analysis rather than a less-expensive frequency-multiplied Nd-YAG laser; the excimer creates tapered cylindrical pits with extremely reproducible and easily characterized geometry. After 4He analysis, U and Th are measured on the same sample surface using the more familiar technique of laser-ablation inductively coupled plasma mass spectrometry (LA-ICPMS). Our early experiments have been done using a frequency-quintupled Nd-YAG microprobe (213nm), While the need to analyze U+Th and He in separate

  10. Diamond Ablators for Inertial Confinement Fusion

    SciTech Connect

    Biener, J; Mirkarimi, P B; Tringe, J W; Baker, S L; Wang, Y M; Kucheyev, S O; Teslich, N E; Wu, K J; Hamza, A V; Wild, C; Woerner, E; Koidl, P; Bruehne, K; Fecht, H

    2005-06-21

    Diamond has a unique combination of physical properties for the inertial confinement fusion ablator application, such as appropriate optical properties, high atomic density, high yield strength, and high thermal conductivity. Here, we present a feasible concept to fabricate diamond ablator shells. The fabrication of diamond capsules is a multi-step process, which involves diamond chemical vapor deposition on silicon mandrels followed by polishing, microfabrication of holes, and removing of the silicon mandrel by an etch process. We also discuss the pros and cons of coarse-grained optical quality and nanocrystalline chemical vapor deposition diamond films for the ablator application.

  11. Ablation response testing of aerospace power supplies

    NASA Astrophysics Data System (ADS)

    Lutz, S. A.; Chan, C. C.

    1993-01-01

    An experimental program was performed to assess the aerothermal ablation response of aerospace power supplies. Full-scale General Purpose Heat Source (GPHS) test articles, Graphite Impact Shell (GIS) test articles, and Lightweight Radioisotope Heater Unit (LWRHU) test articles were all tested without nuclear fuel in simulated reentry environments at the NASA Ames Research Center. Stagnation heating, stagnation pressure, stagnation surface temperature, stagnation surface recession profile, and weight loss measurements were obtained for diffusion-limited and sublimation ablation conditions. The recession profile and weight loss measurements showed an effect of surface features on the stagnation face. The surface features altered the local heating which in turn affected the local ablation.

  12. Bond percolation in higher dimensions

    NASA Astrophysics Data System (ADS)

    Corwin, Eric I.; Stinchcombe, Robin; Thorpe, M. F.

    2013-07-01

    We collect results for bond percolation on various lattices from two to fourteen dimensions that, in the limit of large dimension d or number of neighbors z, smoothly approach a randomly diluted Erdős-Rényi graph. We include results on bond-diluted hypersphere packs in up to nine dimensions, which show the mean coordination, excess kurtosis, and skewness evolving smoothly with dimension towards the Erdős-Rényi limit.

  13. Sub ablation effects of the KTP laser on wound healing.

    PubMed

    Kyzer, M D; Aly, A S; Davidson, J M; Reinisch, L; Ossoff, R H

    1993-01-01

    The KTP laser (wavelength 532 nm) was used in a sub ablative format to determine the effect of low energy density irradiation on the normal healing by primary intention of scalpel skin incisions in rats. Two longitudinal lased strips were created by a 1 cm diameter defocused beam on the shaved, cleaned dorsal epidermis of 32 Sprague-Dawley rates; one strip was produced with a 2.0 W beam (54 J, or 18 J/cm2 total dose), and the other with a 3.5 W beam (94.5 J or 31.5 J/cm2, total dose). Scalpel incisions were made longitudinally within the irradiated zones, using contra lateral scalpel incisions on unirradiated skin as controls. Tensiometric analysis of wound strength was performed at 3, 7, 14, and 23 days following surgery. The data from fresh tissue tensiometry indicate that KTP laser irradiation of skin incisions results in a lower tensile strength for the wound at 7 and 14 days. The decrease in tensile strength is proportional to the total energy density of the exposure. At day 3 and 23, the tensile strength of the wound was independent of the sub ablative laser exposure. The results are in general agreement with studies of the healing process of laser incisions and may help us to understand the details of the healing process from laser incisions. PMID:8426529

  14. Novel microwave applicators for thermal therapy, ablation, and hemostasis

    NASA Astrophysics Data System (ADS)

    Ryan, Thomas P.; Clegg, Peter

    2009-02-01

    Microwave applicators are becoming more prevalent in cancer ablation therapy due to factors of penetration, high power, and shortened treatment time. These applicators create the largest zones of necrosis of available energy sources. Progress has been made both with interstitial applicators for surgical, laparoscopic, or radiological approaches, as well as surface applicators that provide hemostasis or precoagulation prior to resection. Most commonly, the applicators operate at 915 MHz or 2450 MHz, and are well matched to tissue. Surgical applicators are as large as 5.6 mm and have the capability to operate at 100-200 W. With smaller applicators, internal cooling may be required to avoid heating sensitive skin surfaces if used percutaneously or laparoscopically. With the interstitial applicators, animal studies have shown a strong relationship between power and ablation volume, including reaching a steady-state plateau in performance based more on power level and less on time. As shown in-vivo, MW surface applicators are very efficient in surface coagulation for hemostasis or precoagulation and in the treatment of surface breaking lesions. These applicators are also capable of deep penetration as applied from the surface. Characteristic treatment times for interstitial applicators are four minutes and for surface applicators, one minute or less is sufficient. Examples will be shown of multi-organ results with surface coagulation using high-power microwaves. Finally, future trends will be discussed that include treatment planning, multiple applicators, and navigation.

  15. Dimensions of E-Learning.

    ERIC Educational Resources Information Center

    Khan, Badrul H.

    2002-01-01

    Considers factors that must be weighed in creating effective electronic learning environments and presents a basic framework for Web-based or electronic learning. Highlights include the institutional dimension; the pedagogical dimension; technological dimension; interface design; evaluation; management; resource support; and ethical…

  16. Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results

    PubMed Central

    Chenot, Jérémy; Melodelima, David; N'Djin, William Apoutou; Souchon, Rémi; Rivoire, Michel; Chapelon, Jean-Yves

    2010-01-01

    The use of hand-held ultrasound strain imaging for intra-operative real-time visualization of HIFU ablations produced in the liver by a toroidal transducer was investigated. A linear 12 MHz ultrasound imaging probe was used to obtain radiofrequency signals. Using a fast cross-correlation algorithm, strain images were calculated and displayed at 60 frames/s, allowing the use of hand-held strain imaging intra-operatively. Fourteen HIFU lesions were produced in 4 pigs. Intra-operative strain imaging of HIFU ablations in the liver was feasible owing to the high frame rate. The correlation between dimensions measured on gross pathology and dimensions measured on B-mode images and on strain images were R = 0.72 and R = 0.94 respectively. The contrast between ablated and non-ablated tissue was significantly higher (p<0.05) in the strain images (22 dB) than in the B-mode images (9 dB). Strain images allowed equivalent or improved definition of ablated regions when compared with B-mode images. Real-time intra-operative hand-held strain imaging seems to be a promising complement to conventional B-Mode imaging for the guidance of HIFU ablations produced in the liver during an open procedure. These results support that hand-held strain imaging outperforms conventional B-mode ultrasound and could potentially be used for assessment of thermal therapies. PMID:20479514

  17. Flying in Two Dimensions

    NASA Astrophysics Data System (ADS)

    Prakash, Manu; Bardon, Thibaut

    2012-11-01

    It has long been proposed that insect flight might have evolved on a fluid interface. Surface of a pond provides an ecological niche which is exploited by a large number of species capable of locomotion on a fluid interface. Here we describe the discovery of constrained flight in two dimensions as a novel mode of locomotion used by water lily beetles (genus Galerucella). Because water lily beetles are also capable of three-dimensional free flight, this novel two-dimensional locomotion provides us with a unique model system to explore both the transition between two and three dimensional flight and the associated energetics. Here we present a comparative analysis of this transition in terms of wing stroke angles associated with two and three dimensional flight, as well as modeling surface tension forces on both the horizontal and vertical axes. Special attention is paid to the dynamics and energetics of flight in two-dimensions, focusing on the interaction of the wing strokes with the fluid interface and the capillary-gravity wave drag associated with two-dimensional propulsion. Current Address: Ecole Polytechnique, France.

  18. Supergravity in twelve dimension

    NASA Astrophysics Data System (ADS)

    Choi, Kang-Sin

    2015-09-01

    We consider supergravity in twelve dimension, whose dimensional reduction yields eleven-dimensional, IIA, and IIB supergravities. This also provides the effective field theory of F-theory. We must take one direction as a compact circle, so that the Poincaré symmetry and the zero-mode field contents are identical to those of eleven-dimensional supergravity. We also have a tower of massive Kaluza-Klein states to be viewed as the wrapping modes of M2-branes. The twelfth dimension decompactifies only if other two directions are compactified on a torus, restoring different ten dimensional Poincaré symmetry of IIB supergravity, whose missing graviton is provided by components of the rank three tensor field. This condition prevents us from violating the condition on the maximal number of real supercharges, which should be thirty-two. The self-duality condition of the IIB four-form fields is understood from twelve-dimensional Hodge duality. In this framework T-duality is re-interpreted as taking different compactification routes.

  19. Infinitely Large New Dimensions

    SciTech Connect

    Arkani-Hamed, Nima; Dimopoulos, Savas; Dvali, Gia; Kaloper, Nemanja

    2000-01-24

    We construct intersecting brane configurations in anitde Sitter (AdS) space which localize gravity to the intersection region, generalizing the trapping of gravity to any number n of infinite extra dimensions. Since the 4D Planck scale M{sub Pl} is determined by the fundamental Planck scale M{sub *} and the AdS radius L via the familiar relation M{sup 2}{sub Pl}{approx}M{sup 2+n}{sub *}L{sup n} , we get two kinds of theories with TeV scale quantum gravity and submillimeter deviations from Newton's law. With M{sub *}{approx}TeV and L{approx}submillimeter , we recover the phenomenology of theories with large extra dimensions. Alternatively, if M{sub *}{approx}L{sup -1}{approx}M{sub Pl} , and our 3-brane is at a distance of {approx}100M{sup -1}{sub Pl} from the intersection, we obtain a theory with an exponential determination of the weak/Planck hierarchy. (c) 2000 The American Physical Society.

  20. Femtosecond laser ablation of the stapes

    PubMed Central

    McCaughey, Ryan G.; Sun, Hui; Rothholtz, Vanessa S.; Juhasz, Tibor; Wong, Brian J. F.

    2014-01-01

    A femtosecond laser, normally used for LASIK eye surgery, is used to perforate cadaveric human stapes. The thermal side effects of bone ablation are measured with a thermocouple in an inner ear model and are found to be within acceptable limits for inner ear surgery. Stress and acoustic events, recorded with piezoelectric film and a microphone, respectively, are found to be negligible. Optical microscopy, scanning electron microscopy, and optical coherence tomography are used to confirm the precision of the ablation craters and lack of damage to the surrounding tissue. Ablation is compared to that from an Er:YAG laser, the current laser of choice for stapedotomy, and is found to be superior. Ultra-short-pulsed lasers offer a precise and efficient ablation of the stapes, with minimal thermal and negligible mechanical and acoustic damage. They are, therefore, ideal for stapedotomy operations. PMID:19405768

  1. Simple spherical ablative-implosion model

    SciTech Connect

    Mayer, F.J.; Steele, J.T.; Larsen, J.T.

    1980-06-23

    A simple model of the ablative implosion of a high-aspect-ratio (shell radius to shell thickness ratio) spherical shell is described. The model is similar in spirit to Rosenbluth's snowplow model. The scaling of the implosion time was determined in terms of the ablation pressure and the shell parameters such as diameter, wall thickness, and shell density, and compared these to complete hydrodynamic code calculations. The energy transfer efficiency from ablation pressure to shell implosion kinetic energy was examined and found to be very efficient. It may be possible to attach a simple heat-transport calculation to our implosion model to describe the laser-driven ablation-implosion process. The model may be useful for determining other energy driven (e.g., ion beam) implosion scaling.

  2. Nanosecond laser ablation of silver nanoparticle film

    NASA Astrophysics Data System (ADS)

    Chung, Jaewon; Han, Sewoon; Lee, Daeho; Ahn, Sanghoon; Grigoropoulos, Costas P.; Moon, Jooho; Ko, Seung H.

    2013-02-01

    Nanosecond laser ablation of polyvinylpyrrolidone (PVP) protected silver nanoparticle (20 nm diameter) film is studied using a frequency doubled Nd:YAG nanosecond laser (532 nm wavelength, 6 ns full width half maximum pulse width). In the sintered silver nanoparticle film, absorbed light energy conducts well through the sintered porous structure, resulting in ablation craters of a porous dome shape or crown shape depending on the irradiation fluence due to the sudden vaporization of the PVP. In the unsintered silver nanoparticle film, the ablation crater with a clean edge profile is formed and many coalesced nanoparticles of 50 to 100 nm in size are observed inside the ablation crater. These results and an order of magnitude analysis indicate that the absorbed thermal energy is confined within the nanoparticles, causing melting of nanoparticles and their coalescence to larger agglomerates, which are removed following melting and subsequent partial vaporization.

  3. Laser ablation in analytical chemistry - A review

    SciTech Connect

    Russo, Richard E.; Mao, Xianglei; Liu, Haichen; Gonzalez, Jhanis; Mao, Samuel S.

    2001-10-10

    Laser ablation is becoming a dominant technology for direct solid sampling in analytical chemistry. Laser ablation refers to the process in which an intense burst of energy delivered by a short laser pulse is used to sample (remove a portion of) a material. The advantages of laser ablation chemical analysis include direct characterization of solids, no chemical procedures for dissolution, reduced risk of contamination or sample loss, analysis of very small samples not separable for solution analysis, and determination of spatial distributions of elemental composition. This review describes recent research to understand and utilize laser ablation for direct solid sampling, with emphasis on sample introduction to an inductively coupled plasma (ICP). Current research related to contemporary experimental systems, calibration and optimization, and fractionation is discussed, with a summary of applications in several areas.

  4. Neocuproine ablates melanocytes in adult zebrafish.

    PubMed

    O'Reilly-Pol, Thomas; Johnson, Stephen L

    2008-12-01

    The simplest regeneration experiments involve the ablation of a single cell type. While methods exist to ablate the melanocytes of the larval zebrafish,(1,2) no convenient method exists to ablate melanocytes in adult zebrafish. Here, we show that the copper chelator neocuproine (NCP) causes fragmentation and disappearance of melanin in adult zebrafish melanocytes. Adult melanocytes expressing eGFP under the control of a melanocyte-specific promoter also lose eGFP fluorescence in the presence of NCP. We conclude that NCP causes melanocyte death. This death is independent of p53 and melanin, but can be suppressed by the addition of exogenous copper. NCP is ineffective at ablating larval melanocytes. This now provides a tool for addressing questions about stem cells and the maintenance of the adult pigment pattern in zebrafish.

  5. Photodynamic therapy toward selective endometrial ablation

    NASA Astrophysics Data System (ADS)

    Tadir, Yona; Tromberg, Bruce J.; Krasieva, Tatiana B.; Berns, Michael W.

    1993-05-01

    Potential applications of photodynamic therapy for endometrial disease are discussed. Experimental models that may lead to diagnosis and treatment of endometriosis as well as selective endometrial ablation are summarized.

  6. Nanoscale ablation through optically trapped microspheres

    NASA Astrophysics Data System (ADS)

    Fardel, Romain; McLeod, Euan; Tsai, Yu-Cheng; Arnold, Craig B.

    2010-10-01

    The ability to directly create patterns with size scales below 100 nm is important for many applications where the production or repair of high resolution and density features is needed. Laser-based direct-write methods have the benefit of being able to quickly and easily modify and create structures on existing devices, but ablation can negatively impact the overall technique. In this paper we show that self-positioning of near-field objectives through the optical trap assisted nanopatterning (OTAN) method allows for ablation without harming the objective elements. Small microbeads are positioned in close proximity to a substrate where ablation is initiated. Upon ablation, these beads are temporarily displaced from the trap but rapidly return to the initial position. We analyze the range of fluence values for which this process occurs and find that there exists a critical threshold beyond which the beads are permanently ejected.

  7. Thermal Ablation Modeling for Silicate Materials

    NASA Technical Reports Server (NTRS)

    Chen, Yih-Kanq

    2016-01-01

    A general thermal ablation model for silicates is proposed. The model includes the mass losses through the balance between evaporation and condensation, and through the moving molten layer driven by surface shear force and pressure gradient. This model can be applied in the ablation simulation of the meteoroid and the glassy ablator for spacecraft Thermal Protection Systems. Time-dependent axisymmetric computations are performed by coupling the fluid dynamics code, Data-Parallel Line Relaxation program, with the material response code, Two-dimensional Implicit Thermal Ablation simulation program, to predict the mass lost rates and shape change. The predicted mass loss rates will be compared with available data for model validation, and parametric studies will also be performed for meteoroid earth entry conditions.

  8. Preparation of GaN Nanostructures by Laser Ablation of ga Metal

    NASA Astrophysics Data System (ADS)

    El Nadi, Lotfia; Omar, Magdy M.; Mehena, Galila A.; Moniem, Hussien M. A.

    2011-06-01

    In the present study, GaN nanodots (0D) and nanowires (1D) nanostructures were prepared on stainless steal substrates applying laser ablation technique. The target of Ga metal mixed with NaNO2 was introduced in a central bore of a graphite rod of a confined geometry set up. The laser beam was normally focused onto the central bore and the ablated plume of Ga metal was deposited on stainless steal substrate lying below the graphite rod in an atmosphere of slow flow of nitrogen gas with or without ammonia vapor. The pulsed N2 laser beam having a wavelength of 337± 2 nm, pulse duration 15±1 ns and energy per pulse of 15±1 m J, could be focused on the central bore by a cylindrical quartz lens to a spot of dimensions 500 × 700 μm2 t providing target irradiance of 0.2-0.3 GW/cm2 per pulse. The ablated plum was collected after several thousand laser shots. The morphology and structure of the formed nanostructures were investigated by Scanning electron microscope and Energy Dispersive X-Ray Spectroscopy. The growth mechanism is most likely by Solid-Liquid-Vapor phase during the laser ablation processes. The role of the carbon, the NaNO2 and the flowing gas on the growth of Nanostructures of GaN are discussed.

  9. Conformal Bulk Ablation And Therapy Monitoring Using Intracorporeal Image-Treat Ultrasound Arrays

    NASA Astrophysics Data System (ADS)

    Makin, I. R.; Faidi, W.; Mast, T. D.; Runk, M.; Slayton, M.; Barthe, P.

    2005-03-01

    For thermal treatment of soft tissue, an alternative to HIFU is bulk ablation using unfocused or weakly focused intense ultrasound fields. This approach offers faster ablation of large tissue volumes and can be performed in minimally invasive (e.g., laparoscopic or percutaneous) procedures. Here, methods for image-guided ablation of large tissue volumes using compact dual-modality (image and treat) ultrasound arrays are reported including tissue modification caused by the thermal therapy. The dual-modality arrays developed have 16-64 elements spanning apertures of 2-8 mm in elevation and 24-48 mm in azimuth. These devices can provide both therapeutically significant power (e.g. source intensity > 80 W/cm2 at 3.1 MHz) and broad bandwidth (e.g. 50% with a center frequency of 3.5 MHz) for imaging. Imaging challenges associated with limited probe dimensions and channel count are met using signal processing techniques that improve definition and contrast, allowing high-quality B-scan images and useful monitoring information to be obtained during therapy planning and treatment. Using linear and rotational scanning methods, large tissue volumes (20-60 cc) can be treated. The approach can be applied for ablation of other soft tissue pathologies, e.g., kidney, heart, uterus, brain, GI tract, etc.

  10. Principles of the radiative ablation modeling

    NASA Astrophysics Data System (ADS)

    Saillard, Yves; Arnault, Philippe; Silvert, Virginie

    2010-12-01

    Indirectly driven inertial confinement fusion (ICF) rests on the setting up of a radiation temperature within a laser cavity and on the optimization of the capsule implosion ablated by this radiation. In both circumstances, the ablation of an optically thick medium is at work. The nonlinear radiation conduction equations that describe this phenomenon admit different kinds of solutions called generically Marshak waves. In this paper, a completely analytic model is proposed to describe the ablation in the subsonic regime relevant to ICF experiments. This model approximates the flow by a deflagrationlike structure where Hugoniot relations are used in the stationary part from the ablation front up to the isothermal sonic Chapman-Jouguet point and where the unstationary expansion from the sonic point up to the external boundary is assumed quasi-isothermal. It uses power law matter properties. It can also accommodate arbitrary boundary conditions provided the ablation wave stays very subsonic and the surface temperature does not vary too quickly. These requirements are often met in realistic situations. Interestingly, the ablated mass rate, the ablation pressure, and the absorbed radiative energy depend on the time history of the surface temperature, not only on the instantaneous temperature values. The results compare very well with self-similar solutions and with numerical simulations obtained by hydrodynamic code. This analytic model gives insight into the physical processes involved in the ablation and is helpful for optimization and sensitivity studies in many situations of interest: radiation temperature within a laser cavity, acceleration of finite size medium, and ICF capsule implosion, for instance.

  11. Principles of the radiative ablation modeling

    SciTech Connect

    Saillard, Yves; Arnault, Philippe; Silvert, Virginie

    2010-12-15

    Indirectly driven inertial confinement fusion (ICF) rests on the setting up of a radiation temperature within a laser cavity and on the optimization of the capsule implosion ablated by this radiation. In both circumstances, the ablation of an optically thick medium is at work. The nonlinear radiation conduction equations that describe this phenomenon admit different kinds of solutions called generically Marshak waves. In this paper, a completely analytic model is proposed to describe the ablation in the subsonic regime relevant to ICF experiments. This model approximates the flow by a deflagrationlike structure where Hugoniot relations are used in the stationary part from the ablation front up to the isothermal sonic Chapman-Jouguet point and where the unstationary expansion from the sonic point up to the external boundary is assumed quasi-isothermal. It uses power law matter properties. It can also accommodate arbitrary boundary conditions provided the ablation wave stays very subsonic and the surface temperature does not vary too quickly. These requirements are often met in realistic situations. Interestingly, the ablated mass rate, the ablation pressure, and the absorbed radiative energy depend on the time history of the surface temperature, not only on the instantaneous temperature values. The results compare very well with self-similar solutions and with numerical simulations obtained by hydrodynamic code. This analytic model gives insight into the physical processes involved in the ablation and is helpful for optimization and sensitivity studies in many situations of interest: radiation temperature within a laser cavity, acceleration of finite size medium, and ICF capsule implosion, for instance.

  12. Flexible Ablators: Applications and Arcjet Testing

    NASA Technical Reports Server (NTRS)

    Arnold, James O.; Venkatapathy, Ethiraj; Beck, Robin A S.; Mcguire, Kathy; Prabhu, Dinesh K.; Gorbunov, Sergey

    2011-01-01

    Flexible ablators were conceived in 2009 to meet the technology pull for large, human Mars Exploration Class, 23 m diameter hypersonic inflatable aerodynamic decelerators. As described elsewhere, they have been recently undergoing initial technical readiness (TRL) advancement by NASA. The performance limits of flexible ablators in terms of maximum heat rates, pressure and shear remain to be defined. Further, it is hoped that this emerging technology will vastly expand the capability of future NASA missions involving atmospheric entry systems. This paper considers four topics of relevance to flexible ablators: (1) Their potential applications to near/far term human and robotic missions (2) Brief consideration of the balance between heat shield diameter, flexible ablator performance limits, entry vehicle controllability and aft-body shear layer impingement of interest to designers of very large entry vehicles, (3) The approach for developing bonding processes of flexible ablators for use on rigid entry bodies and (4) Design of large arcjet test articles that will enable the testing of flexible ablators in flight-like, combined environments (heat flux, pressure, shear and structural tensile loading). Based on a review of thermal protection system performance requirements for future entry vehicles, it is concluded that flexible ablators have broad applications to conventional, rigid entry body systems and are enabling to large deployable (both inflatable and mechanical) heat shields. Because of the game-changing nature of flexible ablators, it appears that NASA's Office of the Chief Technologist (OCT) will fund a focused, 3-year TRL advancement of the new materials capable of performance in heat fluxes in the range of 200-600 W/sq. cm. This support will enable the manufacture and use of the large-scale arcjet test designs that will be a key element of this OCT funded activity.

  13. Resonant laser ablation: mechanisms and applications

    SciTech Connect

    Anderson, J.E.; Allen, T.M.; Garrett, A.W.; Gill, C.G.; Hemberger, P.H.; Kelly, P.B.; Nogar, N.S.

    1996-10-01

    We report on aspects of resonant laser ablation (RLA) behavior for a number of sample types: metals, alloys, thin films, zeolites and soil. The versatility of RLA is demonstrated, with results on a variety of samples and in several mass spectrometers. In addition, the application to depth profiling of thin films is described; absolute removal rates and detection limits are also displayed. A discussion of possible mechanisms for low-power ablation is presented.

  14. Fabrication of x-ray spiral masks by laser ablation

    NASA Astrophysics Data System (ADS)

    Peele, Andrew G.; Nugent, Keith A.; McMahon, Phillip J.; Paterson, David; Tran, Chanh Q.; Mancuso, Adrian; Mackin, Tracy R.; Hayes, Jason P.; Harvey, Erol C.; McNulty, Ian

    2002-11-01

    The manipulation of x-rays by phase structures is becoming more common through devices such as compound refractive lenses, blazed zone-plates and other structures. A spiral phase modulation structure can be used to condition an x-ray beam to produce an x-ray vortex. An x-ray beam in this form can be used as the first step towards a self-collimating beam. Also it can be used as a controllable pathological feature in studies of x-ray phase retrieval. We describe the microfabrication of a spiral phase modulation structure by excimer laser ablation. A multi-step fabrication using 15 separate chrome-on-quartz mask patterns is used to create a 16 step spiral staircase structure approximating the desired spiral ramp. The results of simulations and initial experimental results are presented.

  15. Laser Ablated Carbon Nanodots for Light Emission.

    PubMed

    Reyes, Delfino; Camacho, Marco; Camacho, Miguel; Mayorga, Miguel; Weathers, Duncan; Salamo, Greg; Wang, Zhiming; Neogi, Arup

    2016-12-01

    The synthesis of fluorescent carbon dots-like nanostructures (CNDs) obtained through the laser ablation of a carbon solid target in liquid environment is reported. The ablation process was induced in acetone with laser pulses of 1064, 532, and 355 nm under different irradiation times. Close-spherical amorphous CNDs with sizes between 5 and 20 nm, whose abundance strongly depends on the ablation parameters were investigated using electron microscopy and was confirmed using absorption and emission spectroscopies. The π- π* electronic transition at 3.76 eV dominates the absorption for all the CNDs species synthesized under different irradiation conditions. The light emission is most efficient due to excitation at 3.54 eV with the photoluminescence intensity centered at 3.23 eV. The light emission from the CNDs is most efficient due to ablation at 355 nm. The emission wavelength of the CNDs can be tuned from the near-UV to the green wavelength region by controlling the ablation time and modifying the ablation and excitation laser wavelength.

  16. Femtosecond laser lithotripsy: feasibility and ablation mechanism

    NASA Astrophysics Data System (ADS)

    Qiu, Jinze; Teichman, Joel M. H.; Wang, Tianyi; Neev, Joseph; Glickman, Randolph D.; Chan, Kin Foong; Milner, Thomas E.

    2010-03-01

    Light emitted from a femtosecond laser is capable of plasma-induced ablation of various materials. We tested the feasibility of utilizing femtosecond-pulsed laser radiation (λ=800 nm, 140 fs, 0.9 mJ/pulse) for ablation of urinary calculi. Ablation craters were observed in human calculi of greater than 90% calcium oxalate monohydrate (COM), cystine (CYST), or magnesium ammonium phosphate hexahydrate (MAPH). Largest crater volumes were achieved on CYST stones, among the most difficult stones to fragment using Holmium:YAG (Ho:YAG) lithotripsy. Diameter of debris was characterized using optical microscopy and found to be less than 20 μm, substantially smaller than that produced by long-pulsed Ho:YAG ablation. Stone retropulsion, monitored by a high-speed camera system with a spatial resolution of 15 μm, was negligible for stones with mass as small as 0.06 g. Peak shock wave pressures were less than 2 bars, measured by a polyvinylidene fluoride (PVDF) needle hydrophone. Ablation dynamics were visualized and characterized with pump-probe imaging and fast flash photography and correlated to shock wave pressures. Because femtosecond-pulsed laser ablates urinary calculi of soft and hard compositions, with micron-sized debris, negligible stone retropulsion, and small shock wave pressures, we conclude that the approach is a promising candidate technique for lithotripsy.

  17. Laser Ablated Carbon Nanodots for Light Emission

    NASA Astrophysics Data System (ADS)

    Reyes, Delfino; Camacho, Marco; Camacho, Miguel; Mayorga, Miguel; Weathers, Duncan; Salamo, Greg; Wang, Zhiming; Neogi, Arup

    2016-09-01

    The synthesis of fluorescent carbon dots-like nanostructures (CNDs) obtained through the laser ablation of a carbon solid target in liquid environment is reported. The ablation process was induced in acetone with laser pulses of 1064, 532, and 355 nm under different irradiation times. Close-spherical amorphous CNDs with sizes between 5 and 20 nm, whose abundance strongly depends on the ablation parameters were investigated using electron microscopy and was confirmed using absorption and emission spectroscopies. The π- π* electronic transition at 3.76 eV dominates the absorption for all the CNDs species synthesized under different irradiation conditions. The light emission is most efficient due to excitation at 3.54 eV with the photoluminescence intensity centered at 3.23 eV. The light emission from the CNDs is most efficient due to ablation at 355 nm. The emission wavelength of the CNDs can be tuned from the near-UV to the green wavelength region by controlling the ablation time and modifying the ablation and excitation laser wavelength.

  18. Basic ablation phenomena during laser thrombolysis

    NASA Astrophysics Data System (ADS)

    Sathyam, Ujwal S.; Shearin, Alan; Prahl, Scott A.

    1997-05-01

    This paper presents studies of microsecond ablation phenomena that take place during laser thrombolysis. The main goals were to optimize laser parameters for efficient ablation, and to investigate the ablation mechanism. Gelatin containing an absorbing dye was used as the clot model. A parametric study was performed to identify the optimal wavelength, spot size, pulse energies, and repetition rate for maximum material removal. The minimum radiant exposures to achieve ablation at any wavelength were measured. The results suggest that most visible wavelengths were equally efficient at removing material at radiant exposures above threshold. Ablation was initiated at surface temperatures just above 100 degrees Celsius. A vapor bubble was formed during ablation. Less than 5% of the total pulse energy is coupled into the bubble energy. A large part of the delivered energy is unaccounted for and is likely released partly as acoustic transients from the vapor expansion and partly wasted as heat. The current laser and delivery systems may not be able to completely remove large clot burden that is sometimes encountered in heart attacks. However, laser thrombolysis may emerge as a favored treatment for strokes where the occlusion is generally smaller and rapid recanalization is of paramount importance. A final hypothesis is that laser thrombolysis should be done at radiant exposures close to threshold to minimize any damaging effects of the bubble dynamics on the vessel wall.

  19. Laser Ablation for Small Hepatocellular Carcinoma

    PubMed Central

    Pacella, Claudio Maurizio; Francica, Giampiero; Di Costanzo, Giovanni Giuseppe

    2011-01-01

    Hepatocellular carcinoma (HCC) is one of the most common malignancies worldwide and is increasingly detected at small size (<5 cm) owing to surveillance programmes in high-risk patients. For these cases, curative therapies such as resection, liver transplantation, or percutaneous ablation have been proposed. When surgical options are precluded, image-guided tumor ablation is recommended as the most appropriate therapeutic choice in terms of tumor local control, safety, and improvement in survival. Laser ablation (LA) represents one of currently available loco-ablative techniques: light is delivered via flexible quartz fibers of diameter from 300 to 600 μm inserted into tumor lesion through either fine needles (21g Chiba needles) or large-bore catheters. The thermal destruction of tissue is achieved through conversion of absorbed light (usually infrared) into heat. A range of different imaging modalities have been used to guide percutaneous laser ablation, but ultrasound and magnetic resonance imaging are most widely employed, according to local experience and resource availability. Available clinical data suggest that LA is highly effective in terms of tumoricidal capability with an excellent safety profile; the best results in terms of long-term survival are obtained in early HCC so that LA can be proposed not only in unresectable cases but, not differently from radiofrequency ablation, also as the first-line treatment. PMID:22191028

  20. Optical modeling of laser ablated microstructures

    NASA Astrophysics Data System (ADS)

    Gower, M. C.; Davies, E.; Holmes, A. S.

    2012-11-01

    From only an a priori knowledge of the optical parameters of a laser beam, the delivery system together with a substrate's material properties, a ray-tracing model capable of predicting the 3-D topology of micro/nanostructures machined by pulsed laser ablation has been developed. The model includes secondary illumination effects produced by the microstructure created by successive pulses (wall reflections, refraction, wave guiding, shadowing, etc.) as well as the complete optical properties of the beam delivery system. We have used material ablation by pulsed excimer lasers and associated beam delivery systems to demonstrate some of the capabilities of the model. Good agreement is obtained between computations and experimental results in terms of the predicted ablation depth per pulse and the wall taper angle of channels and holes. The model can predict ablated profiles of holes and indicate the most efficient drilling strategy in terms of material removal rates. The model also shows diffraction effects are not required to explain the tapering vertical walls observed when ablating microstructures. Finally, the model has been used to demonstrate aberrations in an optical imaging system limiting the creation of submicron features in an ablated microstructure. Provided photons are absorbed linearly in a substrate according to Beer's law with negligible thermal diffusion effects, the model is equally applicable to using other types of pulsed laser sources and systems with imaged or focused beams.

  1. Micrometeoroid ablation simulated in the laboratory

    NASA Astrophysics Data System (ADS)

    Sternovsky, Zoltan; Thomas, Evan W.; DeLuca, Michael; Horanyi, Mihaly; Janches, Diego; Munsat, Tobin L.; Plane, John M. C.

    2016-04-01

    A facility is developed to simulate the ablation of micrometeoroids in laboratory conditions, which also allows measuring the ionization probability of the ablated material. An electrostatic dust accelerator is used to generate iron and meteoric analog particles with velocities 10-50 km/s. The particles are then introduced into a cell filled with nitrogen, air or carbon dioxide gas with pressures adjustable in the 0.02 - 0.5 Torr range, where the partial or complete ablation of the particle occurs over a short distance. An array of biased electrodes is used to collect the ionized products with spatial resolution along the ablating particles' path, allowing thus the study of the temporal resolution of the process. A simple ablation model is used to match the observations. For completely ablated particles the total collected charge directly yields the ionization efficiency for. The measurements using iron particles in N2 and air are in relatively good agreement with earlier data. The measurements with CO2 and He gases, however, are significantly different from the expectations.

  2. Laser Ablated Carbon Nanodots for Light Emission.

    PubMed

    Reyes, Delfino; Camacho, Marco; Camacho, Miguel; Mayorga, Miguel; Weathers, Duncan; Salamo, Greg; Wang, Zhiming; Neogi, Arup

    2016-12-01

    The synthesis of fluorescent carbon dots-like nanostructures (CNDs) obtained through the laser ablation of a carbon solid target in liquid environment is reported. The ablation process was induced in acetone with laser pulses of 1064, 532, and 355 nm under different irradiation times. Close-spherical amorphous CNDs with sizes between 5 and 20 nm, whose abundance strongly depends on the ablation parameters were investigated using electron microscopy and was confirmed using absorption and emission spectroscopies. The π- π* electronic transition at 3.76 eV dominates the absorption for all the CNDs species synthesized under different irradiation conditions. The light emission is most efficient due to excitation at 3.54 eV with the photoluminescence intensity centered at 3.23 eV. The light emission from the CNDs is most efficient due to ablation at 355 nm. The emission wavelength of the CNDs can be tuned from the near-UV to the green wavelength region by controlling the ablation time and modifying the ablation and excitation laser wavelength. PMID:27659953

  3. Novel Laser Ablation Technology for Surface Decontamination

    SciTech Connect

    Cheng, Chung H.

    2004-06-01

    Laser ablation for surface cleaning has been pursued for the removal of paint on airplanes. It has also been pursued for the cleaning of semiconductor surfaces. However, all these approaches have been pursued by laser ablation in air. For highly contaminated surface, laser ablation in air can easily cause secondary contamination. Thus it is not suitable to apply to achieve surface decontamination for DOE facilities since many of these facilities have radioactive contaminants on the surface. Any secondary contamination will be a grave concern. The objective of this project is to develop a novel technology for laser ablation in liquid for surface decontamination. It aims to achieve more efficient surface decontamination without secondary contamination and to evaluate the economic feasibility for large scale surface decontamination with laser ablation in liquid. When laser ablation is pursued in the solution, all the desorbed contaminants will be confined in liquid. The contaminants can be precipitated and subsequently contained in a small volume for disposal. It can reduce the risk of the decontamination workers. It can also reduce the volume of contaminants dramatically.

  4. Modeling Initial Stage of Ablation Material Pyrolysis: Graphitic Precursor Formation and Interfacial Effects

    NASA Technical Reports Server (NTRS)

    Desai, Tapan G.; Lawson, John W.; Keblinski, Pawel

    2010-01-01

    Reactive molecular dynamics simulations are used to study initial stage of pyrolysis of ablation materials and their composites with carbon nanotubes and carbon fibers. The products formed during pyrolysis are characterized and water is found as the primary product in all cases. The water formation mechanisms are analyzed and the value of the activation energy for water formation is estimated. A detailed study on graphitic precursor formation reveals the presence of two temperature zones. In the lower temperature zone (less than 2000 K) polymerization occurs resulting in formation of large, stable graphitic precursors, and in the high temperature zone (greater than 2000 K) polymer scission results in formation of short polymer chains/molecules. Simulations performed in the high temperature zone on the phenolic resin composites (with carbon nanotubes and carbon fibers) shows that the presence of interfaces had no substantial effect on the chain scission rate or the activation energy value for water formation.

  5. Photoreduced silver nanoparticles grown on femtosecond laser ablated, D-shaped fiber probe for surface-enhanced Raman scattering.

    PubMed

    Yin, Zhen; Geng, Youfu; Xie, Qingli; Hong, Xueming; Tan, Xiaoling; Chen, Yuzhi; Wang, Lele; Wang, Wenjia; Li, Xuejin

    2016-07-10

    Surface-enhanced Raman scattering (SERS) probes are made by facile photochemical deposition of silver nanoparticles on a femtosecond (fs) laser ablated, D-shaped fiber. The structure and surface morphology of the probe are investigated by scanning electron microscopy. High-quality SERS signals are detected using Rhodamine 6G molecules via an in situ sensing mode. Experimental results show that the SERS signals increase with the increase of the length of fs laser ablated, D-shaped zone. Our D-shaped fiber SERS probe shows a feasible method for a large active area, high performance, and real-time and remote measurement of SERS signals in biochemical analysis. PMID:27409318

  6. Plasma formation and structural modification below the visible ablation threshold in fused silica upon femtosecond laser irradiation

    SciTech Connect

    Siegel, J.; Puerto, D.; Gawelda, W.; Bachelier, G.; Solis, J.; Ehrentraut, L.; Bonse, J.

    2007-08-20

    We have investigated the temporal and spatial evolution of the ablation process induced in fused silica upon irradiation with single 120 fs laser pulses at 800 nm. Time-resolved microscopy images of the surface reflectivity at 400 nm reveal the existence of a transient plasma distribution with annular shape surrounding the visible ablation crater. The material in this annular zone shows an increased reflectivity after irradiation, consistent with a local refractive index increase of approximately 0.01. White light interferometry measurements indicate a shallow surface depression in this outer region, most likely due to material densification.

  7. Phenomenology of Extra Dimensions

    SciTech Connect

    Hewett, J.L.; /SLAC

    2006-11-07

    If the structure of spacetime is different than that readily observed, gravitational physics, particle physics and cosmology are all immediately affected. The physics of extra dimensions offers new insights and solutions to fundamental questions arising in these fields. Novel ideas and frameworks are continuously born and evolved. They make use of string theoretical features and tools and they may reveal if and how the 11-dimensional string theory is relevant to our four-dimensional world. We have outlined some of the experimental observations in particle and gravitational physics as well as astrophysical and cosmological considerations that can constrain or confirm these scenarios. These developing ideas and the wide interdisciplinary experimental program that is charted out to investigate them mark a renewed effort to describe the dynamics behind spacetime. We look forward to the discovery of a higher dimensional spacetime.

  8. Action languages: Dimensions, effects

    NASA Technical Reports Server (NTRS)

    Hayes, Daniel G.; Streeter, Gordon

    1989-01-01

    Dimensions of action languages are discussed for communication between humans and machines, and the message handling capabilities of object oriented programming systems are examined. Design of action languages is seen to be very contextual. Economical and effective design will depend on features of situations, the tasks intended to be accomplished, and the nature of the devices themselves. Current object oriented systems turn out to have fairly simple and straightforward message handling facilities, which in themselves do little to buffer action or even in some cases to handle competing messages. Even so, it is possible to program a certain amount of discretion about how they react to messages. Such thoughtfulness and perhaps relative autonomy of program modules seems prerequisite to future systems to handle complex interactions in changing situations.

  9. Plans and status of the Beryllium ablator campaign on NIF

    NASA Astrophysics Data System (ADS)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Wilson, D. C.; Olson, R. E.; Krasheninnikova, N. S.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Dewald, E. L.; Edwards, M. J.; MacKinnon, A. J.; Meezan, N. B.

    2014-10-01

    Beryllium has long been known to have excellent properties for indirectly driven ICF implosions including enhanced ablation pressure, implosion velocity, and mass ablation rate. The high ablation velocity leads to stabilization of ablative hydrodynamic instabilities and higher ablation pressures. Recent ``high foot'' experiments have shown ablative Rayleigh-Taylor to be a leading cause of degraded performance for ICF implosions. While Beryllium ablators have these advantages, there are also risks associated with Beryllium target designs. A campaign is underway to design and to test these advantages for comparison with other ablator options and determine which provides the best path forward for ICF. Experiments using Beryllium ablators are expected to start in the late summer of 2014. This presentation will discuss the status of the experiments and layout the plans/goals for the campaign. This work is supported by the US DOE.

  10. Radiofrequency Ablation Beyond the Liver

    PubMed Central

    Neeman, Ziv; Wood, Bradford J.

    2008-01-01

    Radiofrequency ablation (RFA) has begun to show promise for extrahepatic indications. Although much of the reported work on image-guided RFA of liver neoplasms is quite promising, it is even earlier in the evaluation and validation process for extrahepatic RFA, with few short-term and no long-term studies reported. Although there are much more data for liver RFA with almost 3,000 cases reported in the literature, there are a number of ongoing investigations of RFA for tumors in the kidney, lung, bone, breast, bone, and adrenal gland. Debulking and pain control with RFA present palliative options becoming increasingly popular weapons in the interventionalist's oncology arsenal. Metastatic disease with a wide variety of primary histologies in a myriad of locations may be treated with RFA after a careful consideration of the risk-to-benefit ratio balance. The RFA technique can be slightly different outside the liver. Specifically, differing dielectric tissue characteristics may markedly alter the RFA treatment. Each different RFA system has a unique risk and advantage profile. Extrahepatic indications and contraindications will be suggested. Treatment tips and the unique complications and considerations will be introduced for some of the more common extrahepatic locations. PMID:12524646

  11. Dust Ablation in Pluto's Atmosphere

    NASA Astrophysics Data System (ADS)

    Horanyi, M.; Poppe, A. R.; Sternovsky, Z.

    2015-12-01

    Based on measurements by in situ dust detectors onboard the Pioneer and New Horizon spacecraft the total production rate of dust particles born in the Kuiper belt can be estimated to be on the order of 5 x 10 ^3 kg/s in the approximate size range of 1 - 10 micron. These particles slowly migrate inward due to Poynting - Robertson drag and their spatial distribution is shaped by mean motion resonances with the gas giant planets in the outer solar system. The expected mass influx into Pluto's atmosphere is on the order of 50 kg/day, and the arrival speed of the incoming particles is on the order of 3 - 4 km/s. We have followed the ablation history as function of speed and size of dust particles in Pluto's atmosphere, and found that, if the particles are rich in volatiles, they can fully sublimate due to drag heating and deposit their mass in a narrow layer. This deposition might promote the formation of the haze layers observed by the New Horizons spacecraft. This talk will explore the constraints on the composition of the dust particles, as well as on our newly developed models of Pluto's atmosphere that can be learned by matching the altitude where haze layers could be formed.

  12. Dust ablation in Pluto's atmosphere

    NASA Astrophysics Data System (ADS)

    Horanyi, Mihaly; Poppe, Andrew; Sternovsky, Zoltan

    2016-04-01

    Based on measurements by dust detectors onboard the Pioneer 10/11 and New Horizons spacecraft the total production rate of dust particles born in the Edgeworth Kuiper Belt (EKB) has been be estimated to be on the order of 5 ṡ 103 kg/s in the approximate size range of 1 - 10 μm. Dust particles are produced by collisions between EKB objects and their bombardment by both interplanetary and interstellar dust particles. Dust particles of EKB origin, in general, migrate towards the Sun due to Poynting-Robertson drag but their distributions are further sculpted by mean-motion resonances as they first approach the orbit of Neptune and later the other planets, as well as mutual collisions. Subsequently, Jupiter will eject the vast majority of them before they reach the inner solar system. The expected mass influx into Pluto atmosphere is on the order of 200 kg/day, and the arrival speed of the incoming particles is on the order of 3 - 4 km/s. We have followed the ablation history as function of speed and size of dust particles in Pluto's atmosphere, and found that volatile rich particles can fully sublimate due to drag heating and deposit their mass in narrow layers. This deposition might promote the formation of the haze layers observed by the New Horizons spacecraft. This talk will explore the constraints on the composition of the dust particles by comparing the altitude of the deposition layers to the observed haze layers.

  13. Magnetocardiographically-guided catheter ablation.

    PubMed

    Fenici, R R; Covino, M; Cellerino, C; Di Lillo, M; De Filippo, M C; Melillo, G

    1995-12-01

    After more than 30 years since the first magnetocardiographic (MCG) recording was carried out with induction coils, MCG is now approaching the threshold of clinical use. During the last 5 years, in fact, there has been a growing interest of clinicians in this new method which provides an unrivalled accuracy for noninvasive, three-dimensional localization of intracardiac source. An increasing number of laboratories are reporting data validating the use of MCG as an effective method for preoperative localization of arrhythmogenic substrates and for planning the best catheter ablation approach for different arrhythmogenic substrates. In this article, available data from literature have been reviewed. We consider the clinical use of MCG to localize arrhythmogenic substrates in patients with Wolff-Parkinson-White syndrome and in patients with ventricular tachycardia in order to assess the state-of-the-art of the method on a large number of patients. This article also addresses some suggestions for industrial development of more compact, medically oriented MCG equipments at reasonable cost.

  14. Lip Reconstruction after Tumor Ablation

    PubMed Central

    Ebrahimi, Ali; Kalantar Motamedi, Mohammad Hossein; Ebrahimi, Azin; Kazemi, Mohammad; Shams, Amin; Hashemzadeh, Haleh

    2016-01-01

    Approximately 25% of all oral cavity carcinomas involve the lips, and the primary management of these lesions is complete surgical resection. Loss of tissue in the lips after resection is treated with a variety of techniques, depending on the extension and location of the defect. Here we review highly accepted techniques of lip reconstruction and some of new trials with significant clinical results. Reconstruction choice is primarily depend to size of the defect, localization of defect, elasticity of tissues. But patient’s age, comorbidities, and motivation are also important. According to the defect location and size, different reconstruction methods can be used. For defects involved less than 30% of lips, primary closures are sufficient. In defects with 35–70% lip involvement, the Karapandzic, Abbe, Estlander, McGregor or Gillies’ fan flaps or their modifications can be used. When lip remaining tissues are insufficient, cheek tissue can be used in Webster and Bernard advancement flaps and their various modifications. Deltopectoral or radial forearm free flaps can be options for large defects of the lip extending to the Jaws. To achieve best functional and esthetic results, surgeons should be able to choose most appropriate reconstruction method. Considering defects’ size and location, patients’ expects and surgeon’s ability and knowledge, a variety of flaps are presented in order to reconstruct defects resulted from tumor ablation. It’s necessary for surgeons to trace the recent innovations in lip reconstruction to offer best choices to patients. PMID:27308236

  15. A systematic review of surgical ablation versus catheter ablation for atrial fibrillation

    PubMed Central

    Kearney, Katherine; Stephenson, Rowan; Phan, Kevin; Chan, Wei Yen; Huang, Min Yin

    2014-01-01

    Background Atrial fibrillation (AF) is an increasingly prevalent condition in the ageing population, with significantly associated morbidity and mortality. Surgical and catheter ablative strategies both aim to reduce mortality and morbidity through freedom from AF. This review consolidates all currently available comparative data to evaluate these two interventions. Methods A systematic search was conducted across MEDLINE, PubMed, Embase, Cochrane Central Register of Controlled Trials and the Cochrane Database of Systematic Reviews from January 2000 until August 2013. All studies were critically appraised and only those directly comparing surgical and catheter ablation were included. Results Seven studies were deemed suitable for analysis according to the inclusion criteria. Freedom from AF was significantly higher in the surgical ablation group versus the catheter ablation group at 6-month, 12-month and study endpoint follow-up periods. Subgroup analysis demonstrated similar trends, with higher freedom from AF in the surgical ablation group for paroxysmal AF patients. The incidence of pacemaker implantation was higher, while no difference in stroke or cardiac tamponade was demonstrated for the surgical versus catheter ablation groups. Conclusions Current evidence suggests that epicardial ablative strategies are associated with higher freedom from AF, higher pacemaker implantation rates and comparable neurological complications and cardiac tamponade incidence to catheter ablative treatment. Other complications and risks were poorly reported, which warrants further randomized controlled trials (RCTs) of adequate power and follow-up duration. PMID:24516794

  16. Online monitoring of nanoparticles formed during nanosecond laser ablation

    NASA Astrophysics Data System (ADS)

    Nováková, Hana; Holá, Markéta; Vojtíšek-Lom, Michal; Ondráček, Jakub; Kanický, Viktor

    2016-11-01

    The particle size distribution of dry aerosol originating from laser ablation of glass material was monitored simultaneously with Laser Ablation - Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) analysis and two aerosol spectrometers - Fast Mobility Particle Sizer (FMPS) and Aerodynamic Particle Sizer (APS). The unique combination of LA-ICP-MS and FMPS offers the possibility of measuring the particle size distribution every 1 s of the ablation process in the size range of 5.6-560 nm. APS extends the information about particle concentration in the size range 0.54-17 μm. Online monitoring of the dry aerosol was performed for two ablation modes (spot and line with a duration of 80 s) with a 193 nm excimer laser system, using the glass reference material NIST 610 as a sample. Different sizes of laser spot for spot ablation and different scan speeds for line ablation were tested. It was found that the FMPS device is capable of detecting changes in particle size distribution at the first pulses of spot laser ablation and is suitable for laser ablation control simultaneously with LA-ICP-MS analysis. The studied parameters of laser ablation have an influence on the resulting particle size distribution. The line mode of laser ablation produces larger particles during the whole ablation process, while spot ablation produces larger particles only at the beginning, during the ablation of the intact layer of the ablated material. Moreover, spot ablation produces more primary nano-particles (in ultrafine mode size range < 100 nm) than line ablation. This effect is most probably caused by a reduced amount of large particles released from the spot ablation crater. The larger particles scavenge the ultrafine particles during the line ablation mode.

  17. Nanometer thickness laser ablation for spatial control of cell attachment

    NASA Astrophysics Data System (ADS)

    Thissen, H.; Hayes, J. P.; Kingshott, P.; Johnson, G.; Harvey, E. C.; Griesser, H. J.

    2002-10-01

    We demonstrate here a new method to control the location of cells on surfaces in two dimensions, which can be applied to a number of biomedical applications including diagnostic tests and tissue engineered medical devices. Two-dimensional control over cell attachment is achieved by generation of a spatially controlled surface chemistry that allows control over protein adsorption, a process which mediates cell attachment. Here, we describe the deposition of thin allylamine plasma polymer coatings on silicon wafer and perfluorinated poly(ethylene-co-propylene) substrates, followed by grafting of a protein resistant layer of poly(ethylene oxide). Spatially controlled patterning of the surface chemistry was achieved in a fast, one-step procedure by nanometer thickness controlled laser ablation using a 248 nm excimer laser. X-ray photoelectron spectroscopy and atomic force microscopy were used to confirm the production of surface chemistry patterns with a resolution of approximately 1 µm, which is significantly below the dimensions of a single mammalian cell. Subsequent adsorption of the extracellular matrix proteins collagen I and fibronectin followed by cell culture experiments using bovine corneal epithelial cells confirmed that cell attachment is controlled by the surface chemistry pattern. The method is an effective tool for use in a number of in vitro and in vivo applications.

  18. Energy transport analysis in ultrashort pulse laser ablation through combined molecular dynamics and Monte Carlo simulation

    SciTech Connect

    Hu Wenqian; Shin, Yung C.; King, Galen

    2010-09-01

    Mechanisms of energy transport during ultrashort laser pulses (USLPs) ablation are investigated in this paper. Nonequilibrium electron-transport, material ionization, as well as density change effects, are studied using atomistic models--the molecular dynamics (MD) and Monte Carlo (MC) methods, in addition to the previously studied laser absorption, heat conduction, and stress wave propagation. The target material is treated as consisting of two subsystems: valence-electron system and lattice system. MD method is applied to analyze the motion of atoms while MC method is applied for simulating electron dynamics and multiscattering events between particles. Early-time laser-energy absorption and redistribution as well as later-time material ablation and expansion processes are analyzed. This model is validated in terms of ablation depth, lattice/electron temperature distribution as well as evolution, and plume front velocity, through comparisons with experimental or theoretical results in literature. It is generally believed that the hydrodynamic motion of the ablated material is negligible for USLP but this study shows it is true only for its effect on laser-energy deposition. This study shows that the consideration of hydrodynamic expansion and fast density change in both electron and lattice systems is important for obtaining a reliable energy transport mechanism in the locally heated zone.

  19. Damage and ablation thresholds of fused-silica in femtosecond regime

    SciTech Connect

    Chimier, B.; Uteza, O.; Sanner, N.; Sentis, M.; Itina, T.; Lassonde, P.; Legare, F.; Vidal, F.; Kieffer, J. C.

    2011-09-01

    We present an experimental and numerical study of the damage and ablation thresholds at the surface of a dielectric material, e.g., fused silica, using short pulses ranging from 7 to 300 fs. The relevant numerical criteria of damage and ablation thresholds are proposed consistently with experimental observations of the laser irradiated zone. These criteria are based on lattice thermal melting and electronic cohesion temperature, respectively. The importance of the three major absorption channels (multi-photon absorption, tunnel effect, and impact ionization) is investigated as a function of pulse duration (7-300 fs). Although the relative importance of the impact ionization process increases with the pulse duration, our results show that it plays a role even at short pulse duration (<50 fs). For few optical cycle pulses (7 fs), it is also shown that both damage and ablation fluence thresholds tend to coincide due to the sharp increase of the free electron density. This electron-driven ablation regime is of primary interest for thermal-free laser-matter interaction and therefore for the development of high quality micromachining processes.

  20. In vitro assessment of fiber sweeping angle during Q-switched 532-nm laser tissue ablation

    NASA Astrophysics Data System (ADS)

    Rajabhandharaks, Danop; Kang, Hyun Wook; Ko, Woo Jin; Stinson, Douglas; Choi, Benjamin

    2011-03-01

    Photoselective vaporization of the prostate (PVP) has been widely used to treat benign prostatic hyperplasia (BPH). It is well regarded as a safe and minimally invasive procedure and an alternative to the gold standard transurethral resection of the prostate (TURP). Despite of its greatness, as well aware of, the operative procedure time during the PVP is still prolonged. Such attempts have been tried out in order to shorten the operative time and increase its efficacy. However, scientific study to investigate techniques used during the PVP is still lacking. The objective of this study is to investigate how sweeping angle might affect the PVP performance. Porcine kidneys acquired from a local grocery store were used (N=140). A Q-switched 532-nm GreenLight XPSTM (American Medical Systems, Inc., MN, USA), together with 750- μm core MoXyTM fiber, was set to have power levels of 120 W and 180 W. Treatment speed and sweeping speed were fixed at 2 mm/s and 0.5 sweep/s, respectively. Sweeping angles were varied from 0 (no sweeping motion) to 120 degree. Ablation rate, depth, and coagulation zone were measured and quantified. Tissue ablation rate was peaked at 15 and 30 degree for both 120- and 180-W power levels and dramatically decreased beyond 60 degree. At 180 W, ablation rate increased 20% at 30 degree compared to 0 degree. This study demonstrated that ablation rate could be maximized and was contingent upon sweeping angle.

  1. The Mixed Processing Models Development Of Thermal Fracture And Laser Ablation On Glass Substrate

    NASA Astrophysics Data System (ADS)

    Huang, Kuo-Cheng; Wu, Wen-Hong; Tseng, Shih-Feng; Hwang, Chi-Hung

    2011-01-01

    As the industries of cell phone and LCD TV were vigorously flourishing and the manufacturing requirements for LCD glass substrate were getting higher, the thermal fracture cutting technology (TFCT) has progressively become the main technology for LCD glass substrate cutting. Due to using laser as the heat source, the TFCT has many advantages, such as uniform heating, small heat effect zone, and high cutting speed, smooth cutting surface and low residual stress, etc. Moreover, a general laser ablation processing or traditional diamond wheel cutting does not have the last two advantages. The article presents a mixed processing of glass substrate, which consists of TFCT and laser ablation mechanisms, and how to enhance the cutting speed with little ablation laser energy. In this study, a 10W Nd:YAG laser and a 40W CO2 laser are used as the heat source of TFCT and laser ablation processing, respectively. The result indicates that the speed of the mixed processing is more than twice the speed of TFCT. Furthermore, after the mixed processing, the residual stresses in the glass substrates are also smaller.

  2. Ultraviolet femtosecond and nanosecond laser ablation of silicon: Ablation efficiency and laser-induced plasma expansion

    SciTech Connect

    Zeng, Xianzhong; Mao, Xianglei; Greif, Ralph; Russo, Richard E.

    2004-03-23

    Femtosecond laser ablation of silicon in air was studied and compared with nanosecond laser ablation at ultraviolet wavelength (266 nm). Laser ablation efficiency was studied by measuring crater depth as a function of pulse number. For the same number of laser pulses, the fs-ablated crater was about two times deeper than the ns-crater. The temperature and electron number density of the pulsed laser-induced plasma were determined from spectroscopic measurements. The electron number density and temperature of fs-pulse plasmas decreased faster than ns-pulse plasmas due to different energy deposition mechanisms. Images of the laser-induced plasma were obtained with femtosecond time-resolved laser shadowgraph imaging. Plasma expansion in both the perpendicular and the lateral directions to the laser beam were compared for femtosecond and nanosecond laser ablation.

  3. Femtosecond ultraviolet laser ablation of silver and comparison with nanosecond ablation

    SciTech Connect

    Toftmann, B.; Schou, J.; Doggett, B.; Budtz-Jorgensen, C.; Lunney, J. G.

    2013-02-28

    The ablation plume dynamics arising from ablation of silver with a 500 fs, 248 nm laser at {approx}2 J cm{sup -2} has been studied using angle-resolved Langmuir ion probe and thin film deposition techniques. For the same laser fluence, the time-of-flight ion signals from femtosecond and nanosecond laser ablation are similar; both show a singly peaked time-of-flight distribution. The angular distribution of ion emission and the deposition are well described by the adiabatic and isentropic model of plume expansion, though distributions for femtosecond ablation are significantly narrower. In this laser fluence regime, the energy efficiency of mass ablation is higher for femtosecond pulses than for nanosecond pulses, but the ion production efficiency is lower.

  4. Photoacoustic characterization of radiofrequency ablation lesions

    NASA Astrophysics Data System (ADS)

    Bouchard, Richard; Dana, Nicholas; Di Biase, Luigi; Natale, Andrea; Emelianov, Stanislav

    2012-02-01

    Radiofrequency ablation (RFA) procedures are used to destroy abnormal electrical pathways in the heart that can cause cardiac arrhythmias. Current methods relying on fluoroscopy, echocardiography and electrical conduction mapping are unable to accurately assess ablation lesion size. In an effort to better visualize RFA lesions, photoacoustic (PA) and ultrasonic (US) imaging were utilized to obtain co-registered images of ablated porcine cardiac tissue. The left ventricular free wall of fresh (i.e., never frozen) porcine hearts was harvested within 24 hours of the animals' sacrifice. A THERMOCOOLR Ablation System (Biosense Webster, Inc.) operating at 40 W for 30-60 s was used to induce lesions through the endocardial and epicardial walls of the cardiac samples. Following lesion creation, the ablated tissue samples were placed in 25 °C saline to allow for multi-wavelength PA imaging. Samples were imaged with a VevoR 2100 ultrasound system (VisualSonics, Inc.) using a modified 20-MHz array that could provide laser irradiation to the sample from a pulsed tunable laser (Newport Corp.) to allow for co-registered photoacoustic-ultrasound (PAUS) imaging. PA imaging was conducted from 750-1064 nm, with a surface fluence of approximately 15 mJ/cm2 maintained during imaging. In this preliminary study with PA imaging, the ablated region could be well visualized on the surface of the sample, with contrasts of 6-10 dB achieved at 750 nm. Although imaging penetration depth is a concern, PA imaging shows promise in being able to reliably visualize RF ablation lesions.

  5. Production of copper and brass nanoparticles upon laser ablation in liquids

    SciTech Connect

    Kazakevich, Pavel V; Simakin, Aleksandr V; Shafeev, Georgii A; Voronov, Valerii V

    2004-10-31

    The production of nanoparticles upon ablation of copper and brass by pulsed radiation from Nd:YAG and copper lasers in water, ethanol, and acetone is studied. The nanoparticles were investigated by the methods of X-ray diffractometry, optical spectroscopy, and transmission electron microscopy. The produced copper and brass nanoparticles were shown to exhibit a plasmon resonance lying in the visible spectral range near 580 and 510 nm. The brass nanoparticles produced by ablation in ethanol have a shell approximately 10-nm thick for an average dimension of 20-30 nm. A chemical modification of ethanol was observed, which manifested itself in the appearance of intense UV absorption bands. Upon laser irradiation of brass nanoparticles in a liquid their absorption spectrum gradually transformed into the spectrum of copper nanoparticles. (interaction of laser radiation with matter)

  6. UV-laser ablation of ionic liquid matrices.

    PubMed

    Hellwig, Nils; Thrun, Alexander; Muskat, Tassilo; Grotemeyer, Jürgen

    2009-12-01

    Ionic liquid matrices are a new class of matrices used in MALDI mass spectrometry. The ablation process of several ionic liquid matrices was studied by determining the velocity distribution of ablated neutral matrix molecules. This was done by a postionization approach, where the neutrals were ionized in the ablation plume by a second laser pulse. It was found that a second, time-delayed ablation event occurs consisting completely of neutral molecules. To explain this, the reflected-shockwave model is used, which assumes that the shockwave emerging from the laser ablation is reflected at the sample holder surface. When the shockwave arrives at the sample surface it causes a second ablation.

  7. Ablation threshold and ablation mechanism transition of polyoxymethylene irradiated by CO2 laser.

    PubMed

    Li, Gan; Cheng, Mousen; Li, Xiaokang

    2016-09-01

    Polyoxymethylene (POM) decomposes gradually as it is heated up by the irradiation of CO2 laser; the long-chain molecules of POM are broken into short chains, which leads to the lowering of the melting point and the critical temperature of the ablation products. When the product temperature is above the melting point, ablation comes up in the way of vaporization; when the product temperature is higher than the critical temperature, all liquid products are transformed into gas instantly and the ablation mechanism is changed. The laser fluence at which significant ablation is observed is defined as the ablation threshold, and the fluence corresponding to the ablation mechanism changing is denoted as the flyover threshold. In this paper, random pyrolysis is adopted to describe the pyrolytic decomposition of POM, and consequently, the components of the pyrolysis products under different pyrolysis rates are acquired. The Group Contribution method is used to count the thermodynamic properties of the pyrolysis products, and the melting point and the critical temperature of the product mixture are obtained by the Mixing Law. The Knudsen layer relationship is employed to evaluate the ablation mass removal when the product temperature is below the critical temperature. The gas dynamics conservation laws associated with the Jouguet condition are used to calculate the mass removal when the product temperature is higher than the critical temperature. Based on the model, a set of simulations for various laser intensities and lengths are carried out to generalize the relationships between the thresholds and the laser parameters. Besides the ablated mass areal density, which fits the experimental data quite well, the ablation temperature, pyrolysis rate, and product components are also discussed for a better understanding of the ablation mechanism of POM.

  8. Ablation threshold and ablation mechanism transition of polyoxymethylene irradiated by CO2 laser.

    PubMed

    Li, Gan; Cheng, Mousen; Li, Xiaokang

    2016-09-01

    Polyoxymethylene (POM) decomposes gradually as it is heated up by the irradiation of CO2 laser; the long-chain molecules of POM are broken into short chains, which leads to the lowering of the melting point and the critical temperature of the ablation products. When the product temperature is above the melting point, ablation comes up in the way of vaporization; when the product temperature is higher than the critical temperature, all liquid products are transformed into gas instantly and the ablation mechanism is changed. The laser fluence at which significant ablation is observed is defined as the ablation threshold, and the fluence corresponding to the ablation mechanism changing is denoted as the flyover threshold. In this paper, random pyrolysis is adopted to describe the pyrolytic decomposition of POM, and consequently, the components of the pyrolysis products under different pyrolysis rates are acquired. The Group Contribution method is used to count the thermodynamic properties of the pyrolysis products, and the melting point and the critical temperature of the product mixture are obtained by the Mixing Law. The Knudsen layer relationship is employed to evaluate the ablation mass removal when the product temperature is below the critical temperature. The gas dynamics conservation laws associated with the Jouguet condition are used to calculate the mass removal when the product temperature is higher than the critical temperature. Based on the model, a set of simulations for various laser intensities and lengths are carried out to generalize the relationships between the thresholds and the laser parameters. Besides the ablated mass areal density, which fits the experimental data quite well, the ablation temperature, pyrolysis rate, and product components are also discussed for a better understanding of the ablation mechanism of POM. PMID:27607281

  9. Dimensions of systems biology.

    PubMed

    Huang, S; Wikswo, J

    2006-01-01

    Systems biology, possibly the latest sub-discipline of biology, has arisen as a result of the shockwave of genomic and proteomic data that has appeared in the past few years. However, despite ubiquitous initiatives that carry this label, there is no precise definition of systems biology other than the implication of a new, all-encompassing, multidisciplinary endeavor. Here we propose that systems biology is more than the integration of biology with methods of the physical and computational sciences, and also more than the expansion of the single-pathway approach to embracing genome-scale networks. It is the discipline that specifically addresses the fundamental properties of the complexity that living systems represent. To facilitate the discussion, we dissect and project the multifaceted systems complexity of living organisms into five dimensions: (1) molecular complexity; (2) structural complexity; (3) temporal complexity; (4) abstraction and emergence; and (5) algorithmic complexity. This "five-dimensional space" may provide a framework for comparing, classifying, and complementing the vast diversity of existing systems biology programs and their goals, and will also give a glimpse of the magnitude of the scientific problems associated with unraveling the ultimate mysteries of life.

  10. Physics in one dimension

    NASA Astrophysics Data System (ADS)

    van Houselt, A.; Schäfer, J.; Zandvliet, H. J. W.; Claessen, R.

    2013-01-01

    With modern microelectronics moving towards smaller and smaller length scales on the (sub-) nm scale, quantum effects (apart from band structure and band gaps) have begun to play an increasingly important role. This especially concerns dimensional confinement to 2D (high electron mobility transistors and integer/fractional quantum Hall effect physics, graphene and topological insulators) and 1D (with electrical connections eventually reaching the quantum limit). Recent developments in the above-mentioned areas have revealed that the properties of electron systems become increasingly exotic as one progresses from the 3D case into lower dimensions. As compared to 2D electron systems, much less experimental progress has been achieved in the field of 1D electron systems. The main reason for the lack of experimental results in this field is related to the difficulty of realizing 1D electron systems. Atom chains created in quantum mechanical break junction set-ups are too short to exhibit the typically 1D signatures. As an alternative, atomic chains can be produced on crystal surfaces, either via assembling them one-by-one using a scanning tunnelling microscope or via self-assembly. The drawback of the latter systems is that the atomic chains are not truly 1D since they are coupled to the underlying crystal and sometimes even to the neighbouring chains. In retrospect, this coupling turns out to be an absolute necessity in the experiment since true 1D systems are disordered at any non-zero temperature [1]. The coupling to the crystal and/or neighbouring chains shifts the phase transition, for example, a Peierls instability, to a non-zero temperature and thus allows experiments to be performed in the ordered state. Here, we want to emphasize that the electronic properties of the 1D electron system are fundamentally different from its 2D and 3D counterparts. The Fermi liquid theory, which is applicable to 2D and 3D electron systems, breaks down spectacularly in the 1D case

  11. Physics in one dimension

    NASA Astrophysics Data System (ADS)

    van Houselt, A.; Schäfer, J.; Zandvliet, H. J. W.; Claessen, R.

    2013-01-01

    With modern microelectronics moving towards smaller and smaller length scales on the (sub-) nm scale, quantum effects (apart from band structure and band gaps) have begun to play an increasingly important role. This especially concerns dimensional confinement to 2D (high electron mobility transistors and integer/fractional quantum Hall effect physics, graphene and topological insulators) and 1D (with electrical connections eventually reaching the quantum limit). Recent developments in the above-mentioned areas have revealed that the properties of electron systems become increasingly exotic as one progresses from the 3D case into lower dimensions. As compared to 2D electron systems, much less experimental progress has been achieved in the field of 1D electron systems. The main reason for the lack of experimental results in this field is related to the difficulty of realizing 1D electron systems. Atom chains created in quantum mechanical break junction set-ups are too short to exhibit the typically 1D signatures. As an alternative, atomic chains can be produced on crystal surfaces, either via assembling them one-by-one using a scanning tunnelling microscope or via self-assembly. The drawback of the latter systems is that the atomic chains are not truly 1D since they are coupled to the underlying crystal and sometimes even to the neighbouring chains. In retrospect, this coupling turns out to be an absolute necessity in the experiment since true 1D systems are disordered at any non-zero temperature [1]. The coupling to the crystal and/or neighbouring chains shifts the phase transition, for example, a Peierls instability, to a non-zero temperature and thus allows experiments to be performed in the ordered state. Here, we want to emphasize that the electronic properties of the 1D electron system are fundamentally different from its 2D and 3D counterparts. The Fermi liquid theory, which is applicable to 2D and 3D electron systems, breaks down spectacularly in the 1D case

  12. Johannes Kepler and Extra Dimensions

    NASA Astrophysics Data System (ADS)

    Hendry, Archibald W.

    2004-02-01

    How many dimensions are there? The answer used to be four — three spatial and one time dimension. Maybe it still is, though nowadays we hear that the answer may be more, perhaps many more. Many of our students have heard about this on television or read about it. They want to know more. Why do physicists think we need more than three spatial dimensions? What's the point of it all?

  13. Anomalous dimensions of conformal baryons

    NASA Astrophysics Data System (ADS)

    Pica, Claudio; Sannino, Francesco

    2016-10-01

    We determine the anomalous dimensions of baryon operators for the three-color theory as functions of the number of massless flavors within the conformal window to the maximum known order in perturbation theory. We show that the anomalous dimension of the baryon is controllably small, within the δ expansion, for a wide range of number of flavors. We also find that this is always smaller than the anomalous dimension of the fermion mass operator. These findings challenge the partial compositeness paradigm.

  14. Time-resolved analysis of thickness-dependent dewetting and ablation of silver films upon nanosecond laser irradiation

    NASA Astrophysics Data System (ADS)

    Qi, Dongfeng; Paeng, Dongwoo; Yeo, Junyeob; Kim, Eunpa; Wang, Letian; Chen, Songyan; Grigoropoulos, Costas P.

    2016-05-01

    Nanosecond pulsed laser dewetting and ablation of thin silver films is investigated by time-resolved imaging. Laser pulses of 532 nm wavelength and 5 ns temporal width are irradiated on silver films of different thicknesses (50 nm, 80 nm, and 350 nm). Below the ablation threshold, it is observed that the dewetting process does not conclude until 630 ns after the laser irradiation for all samples, forming droplet-like particles in the spot central region. At higher laser intensities, ablative material removal occurs in the spot center. Cylindrical rims are formed in the peripheral dewetting zone due to the solidification of transported matter at about 700 ns following the laser pulse exposure. In addition to these features, droplet fingers are superposed upon irradiation of 350-nm thick silver films with higher intensity.

  15. Effect of Laser Wavelength and Ablation Time on Pulsed Laser Ablation Synthesis of AL Nanoparticles in Ethanol

    NASA Astrophysics Data System (ADS)

    Baladi, A.; Mamoory, R. Sarraf

    Aluminum nanoparticles were synthesized by pulsed laser ablation of Al targets in ethanol for 5-15 minutes using the 1064 and 533 nm wavelengths of a Nd:YAG laser with energies of 280-320 mJ per pulse. It has been found that higher wavelength leads to significantly higher ablation efficiency, and finer spherical nanoparticles are also synthesized. Besides, it was obvious that higher ablation time resulted in higher ablated mass, while lower ablation rate was observed. Finer nanoparticles, moreover, are synthesized in higher ablation times.

  16. Dental ablation with 1064 nm, 500 ps, Diode pumped solid state laser: A preliminary study

    PubMed Central

    Fornaini, Carlo; Cucinotta, Annamaria; Merigo, Elisabetta; Vescovi, Paolo; Selleri, Stefano

    2013-01-01

    Background: The Er:YAG laser in conservative dentistry is. good alternative to conventional instruments. Though several studies show the advantages of these devices, some drawbacks and unsolved problems are still present, such as the cost of the device and the large dimensions of the equipment. Purpose: In the present study, the effectiveness of dental surface ablation with a picosecond infrared diode-pumped solid-state (DPSS) laser was investigated. In vitro tests on extracted human teeth were carried out, with assessment of the ablation quality in the tooth and thermal increase inside the pulp chamber. Materials and Methods: A solid-state picosecond laser was used for the experiments. The samples were exposed to laser energy at 1064 nm at a frequency of 30 kHz and a 500 ps pulse width. The target teeth were cooled during exposures. The internal temperature of the pulp chamber was monitored with. thermocouple. Results: Optical microscope images showed effective ablation with the absence of carbonisation and micro-cracks. The cooling maintained the temperature rise in the pulp chamber below the permitted 5.5°C. Discussion: The main problem with the use of lasers in dentistry when teeth are the target is the heat generated in the pulp chamber of the target teeth. With lasers operating in the femtosecond mode, a better management of the internal temperature is possible, but is offset by the high cost of such devices. With the ps domain system used in the present study together with cooling using chilled water, effective and clean ablation could be achieved with a controlled thermal effect in the pulp chamber. Conclusions: In this preliminary study with a picosecond domain DPSS laser using water cooling for the target, effective hard tissue ablation was achieved keeping the thermal increase in the pulp within the permitted range. The results suggest that this system could be used in clinical practice with appropriate modifications. PMID:24204093

  17. Exterior dimension of fat fractals

    NASA Technical Reports Server (NTRS)

    Grebogi, C.; Mcdonald, S. W.; Ott, E.; Yorke, J. A.

    1985-01-01

    Geometric scaling properties of fat fractal sets (fractals with finite volume) are discussed and characterized via the introduction of a new dimension-like quantity which is called the exterior dimension. In addition, it is shown that the exterior dimension is related to the 'uncertainty exponent' previously used in studies of fractal basin boundaries, and it is shown how this connection can be exploited to determine the exterior dimension. Three illustrative applications are described, two in nonlinear dynamics and one dealing with blood flow in the body. Possible relevance to porous materials and ballistic driven aggregation is also noted.

  18. [Radiofrequency transcatheter ablation in atrial tachycardia].

    PubMed

    Velázquez Rodríguez, E; Morales Hernández, J A

    2000-01-01

    Incessant atrial tachycardia is an infrequent arrhythmia. Specially difficult to treat medically. Radiofrequency catheter ablation has been used successfully to cure a variety of supraventricular tachycardias. The purpose of this work is to report our initial experience in the treatment of atrial tachycardia. Ten patients, mean age 28.7 +/- 15 year with conventional drug-resistant symptomatic atrial tachycardia were treated with selective ablation of the focus using radiofrequency energy. It was found an abnormal automaticity in 10 tachycardias and in only one patient intra-atrial reentrant was supported. Radiofrequency energy was successful in 10 of 11 tachycardias with a mean of 9.3 +/- 6.8 applications using the technique of local atrial electrogram activation time with a mean value of -54 +/- -31 milliseconds at the successful ablation sites. No complications were observed and one patient had an early clinical recurrence. All patients with successful ablation are symptom-free, in sinus rhythm and without antiarrhythmic medications after 1 to 28 months of follow-up. Our initial experience support that radiofrequency catheter ablation is a safe and effective therapeutic option for incessant atrial tachycardia. PMID:10855411

  19. Fracture in Phenolic Impregnated Carbon Ablator

    NASA Technical Reports Server (NTRS)

    Agrawal, Parul; Chavez-Garcia, Jose; Pham, John

    2013-01-01

    This paper describes the development of a novel technique to understand the failure mechanisms inside thermal protection materials. The focus of this research is on the class of materials known as phenolic impregnated carbon ablators. It has successfully flown on the Stardust spacecraft and is the thermal protection system material chosen for the Mars Science Laboratory and SpaceX Dragon spacecraft. Although it has good thermal properties, structurally, it is a weak material. To understand failure mechanisms in carbon ablators, fracture tests were performed on FiberForm(Registered TradeMark) (precursor), virgin, and charred ablator materials. Several samples of these materials were tested to investigate failure mechanisms at a microstructural scale. Stress-strain data were obtained simultaneously to estimate the tensile strength and toughness. It was observed that cracks initiated and grew in the FiberForm when a critical stress limit was reached such that the carbon fibers separated from the binder. However, both for virgin and charred carbon ablators, crack initiation and growth occurred in the matrix (phenolic) phase. Both virgin and charred carbon ablators showed greater strength values compared with FiberForm samples, confirming that the presence of the porous matrix helps in absorbing the fracture energy.

  20. Design Calculations for NIF Convergent Ablator Experiments

    NASA Astrophysics Data System (ADS)

    Olson, R. E.; Callahan, D. A.; Hicks, D. G.; Landen, O. L.; Langer, S. H.; Meezan, N. B.; Spears, B. K.; Widmann, K.; Kline, J. L.; Wilson, D. C.; Petrasso, R. D.; Leeper, R. J.

    2010-11-01

    Design calculations for NIF convergent ablator experiments will be described. The convergent ablator experiments measure the implosion trajectory, velocity, and ablation rate of an x-ray driven capsule and are a important component of the U. S. National Ignition Campaign at NIF. The design calculations are post-processed to provide simulations of the key diagnostics -- 1) Dante measurements of hohlraum x-ray flux and spectrum, 2) streaked radiographs of the imploding ablator shell, 3) wedge range filter measurements of D-He3 proton output spectra, and 4) GXD measurements of the imploded core. The simulated diagnostics will be compared to the experimental measurements to provide an assessment of the accuracy of the design code predictions of hohlraum radiation temperature, capsule ablation rate, implosion velocity, shock flash areal density, and x-ray bang time. Post-shot versions of the design calculations are used to enhance the understanding of the experimental measurements and will assist in choosing parameters for subsequent shots and the path towards optimal ignition capsule tuning. *SNL, LLNL, and LANL are operated under US DOE contracts DE-AC04-94AL85000. DE-AC52-07NA27344, and DE-AC04-94AL85000.

  1. Design calculations for NIF convergent ablator experiments.

    SciTech Connect

    Callahan, Debra; Leeper, Ramon Joe; Spears, B. K.; Zylstra, A.; Seguin, F.; Landen, Otto L.; Petrasso, R. D.; Rinderknecht, H.; Kline, J. L.; Frenje, J.; Wilson, D. C.; Langer, S. H.; Widmann, K.; Meezan, Nathan B.; Hicks, Damien G.; Olson, Richard Edward

    2010-11-01

    Design calculations for NIF convergent ablator experiments will be described. The convergent ablator experiments measure the implosion trajectory, velocity, and ablation rate of an x-ray driven capsule and are a important component of the U. S. National Ignition Campaign at NIF. The design calculations are post-processed to provide simulations of the key diagnostics: (1) Dante measurements of hohlraum x-ray flux and spectrum, (2) streaked radiographs of the imploding ablator shell, (3) wedge range filter measurements of D-He3 proton output spectra, and (4) GXD measurements of the imploded core. The simulated diagnostics will be compared to the experimental measurements to provide an assessment of the accuracy of the design code predictions of hohlraum radiation temperature, capsule ablation rate, implosion velocity, shock flash areal density, and x-ray bang time. Post-shot versions of the design calculations are used to enhance the understanding of the experimental measurements and will assist in choosing parameters for subsequent shots and the path towards optimal ignition capsule tuning.

  2. Test of Thermal Transport Models through Dynamic Overpressure Stabilization of Ablation-Front Perturbation Growth in Laser-Driven CH Foils

    SciTech Connect

    Gotchev, O.V.; Goncharov, V.N.; Knauer, J.P.; Boehly, T.R.; Collins, T.J.B.; Epstein, R.; Jaanimagi, P.A.; Meyerhofer, D.D.

    2006-03-24

    Heat-flow-induced dynamic overpressure at the perturbed ablation front of an ICF target can stabilize the ablative Richtmyer/Meshkov-like instability and mitigate the subsequent ablative Rayleigh/Taylor (RT) instability. A series of experiments was performed on the OMEGA laser to quantify the dynamic overpressure stabilization during the shock transit. Analysis of the experimental data using hydrocode simulations shows that the observed oscillatory evolution of the ablation-front perturbations depends on Dc, the size of the thermal conduction zone, and the fluid velocity in the blowoff region Vbl that are sensitive to the thermal transport model used. We show that the simulations match the experiment well when the time dependence of the heat-flux inhibition is taken into account using a recently developed nonlocal heat transport model.

  3. Damage morphology and mechanism in ablation cutting of thin glass sheets with picosecond pulsed lasers

    NASA Astrophysics Data System (ADS)

    Sun, Mingying; Eppelt, Urs; Hartmann, Claudia; Schulz, Wolfgang; Zhu, Jianqiang; Lin, Zunqi

    2016-06-01

    We experimentally investigated the morphology and mechanism of laser-induced damage in the ablation cutting of thin glass sheets with picosecond pulsed lasers and we compared the experimental results to our models. After several passes of laser ablation, we observed two different kinds of damage morphologies on the cross-section of the cut channel. They are distinguished to be the damage region caused by high-density free-electrons and the heat-affected zone due to the heat accumulation, respectively. Furthermore, micro-cracks can be observed on the top surface of the workpiece near the cut edge. The nano-cracks could be generated by high energy free-electrons but opened and developed to be visible micro-cracks by thermal stress generated in the heat-affected zone. The crack length was proportional to the volume of heat-affected zone. Heat-affected-zone and visible-cracks free conditions of glass cutting were achieved by controlling the repetition rate and spatial overlap of laser pulses.

  4. Heat sink effect on tumor ablation characteristics as observed in monopolar radiofrequency, bipolar radiofrequency, and microwave, using ex vivo calf liver model.

    PubMed

    Pillai, Krishna; Akhter, Javid; Chua, Terence C; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L

    2015-03-01

    Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices.With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored.With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres.Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected.Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5.MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink.

  5. Cryoballoon or radiofrequency ablation for symptomatic paroxysmal atrial fibrillation: reintervention, rehospitalization, and quality-of-life outcomes in the FIRE AND ICE trial

    PubMed Central

    Kuck, Karl-Heinz; Fürnkranz, Alexander; Chun, K.R. Julian; Metzner, Andreas; Ouyang, Feifan; Schlüter, Michael; Elvan, Arif; Lim, Hae W.; Kueffer, Fred J.; Arentz, Thomas; Albenque, Jean-Paul; Tondo, Claudio; Kühne, Michael; Sticherling, Christian; Brugada, Josep

    2016-01-01

    Aims The primary safety and efficacy endpoints of the randomized FIRE AND ICE trial have recently demonstrated non-inferiority of cryoballoon vs. radiofrequency current (RFC) catheter ablation in patients with drug-refractory symptomatic paroxysmal atrial fibrillation (AF). The aim of the current study was to assess outcome parameters that are important for the daily clinical management of patients using key secondary analyses. Specifically, reinterventions, rehospitalizations, and quality-of-life were examined in this randomized trial of cryoballoon vs. RFC catheter ablation. Methods and results Patients (374 subjects in the cryoballoon group and 376 subjects in the RFC group) were evaluated in the modified intention-to-treat cohort. After the index ablation, log-rank testing over 1000 days of follow-up demonstrated that there were statistically significant differences in favour of cryoballoon ablation with respect to repeat ablations (11.8% cryoballoon vs. 17.6% RFC; P = 0.03), direct-current cardioversions (3.2% cryoballoon vs. 6.4% RFC; P = 0.04), all-cause rehospitalizations (32.6% cryoballoon vs. 41.5% RFC; P = 0.01), and cardiovascular rehospitalizations (23.8% cryoballoon vs. 35.9% RFC; P < 0.01). There were no statistical differences between groups in the quality-of-life surveys (both mental and physical) as measured by the Short Form-12 health survey and the EuroQol five-dimension questionnaire. There was an improvement in both mental and physical quality-of-life in all patients that began at 6 months after the index ablation and was maintained throughout the 30 months of follow-up. Conclusion Patients treated with cryoballoon as opposed to RFC ablation had significantly fewer repeat ablations, direct-current cardioversions, all-cause rehospitalizations, and cardiovascular rehospitalizations during follow-up. Both patient groups improved in quality-of-life scores after AF ablation. Clinical trial registration ClinicalTrials.gov identifier: NCT01490814

  6. Knowledge-based flow field zoning

    NASA Technical Reports Server (NTRS)

    Andrews, Alison E.

    1988-01-01

    Automation flow field zoning in two dimensions is an important step towards easing the three-dimensional grid generation bottleneck in computational fluid dynamics. A knowledge based approach works well, but certain aspects of flow field zoning make the use of such an approach challenging. A knowledge based flow field zoner, called EZGrid, was implemented and tested on representative two-dimensional aerodynamic configurations. Results are shown which illustrate the way in which EZGrid incorporates the effects of physics, shape description, position, and user bias in a flow field zoning.

  7. Characterization of tissue response to radiofrequency ablation using 3D model-based analysis of interventional MR images

    NASA Astrophysics Data System (ADS)

    Weinberg, Brent D.; Lazebnik, Roee S.; Breen, Michael S.; Lewin, Jonathan S.; Wilson, David L.

    2003-05-01

    Using magnetic resonance imaging (MRI), real-time guidance is feasible for radiofrequency (RF) current ablation of pathologic tissue. Lesions have a characteristic two-zone appearance: an inner core (Zone I) surrounded by a hyper-intense rim (Zone II). A better understanding of both the immediate (hyper-acute) and delayed (sub-acute) physiological response of the target tissue will aid development of minimally invasive tumor treatment strategies. We performed in vivo RF ablations in a rabbit thigh model and characterized the tissue response to treatment through contrast enhanced (CE) T1 and T2 weighted MR images at two time points. We measured zonal grayscale changes as well as zone volume changes using a 3D computationally fitted globally deformable parametric model. Comparison over time demonstrated an increase in the volume of both the inner necrotic core (mean 56.5% increase) and outer rim (mean 16.8% increase) of the lesion. Additionally, T2 images of the lesion exhibited contrast greater than or equal to CE T1 (mean 35% improvement). This work establishes a foundation for the clinical use of T2 MR images coupled with a geometric model of the ablation for noninvasive lesion monitoring and characterization.

  8. Excimer laser ablation of aluminum: influence of spot size on ablation rate

    NASA Astrophysics Data System (ADS)

    Shaheen, M. E.; Gagnon, J. E.; Fryer, B. J.

    2016-11-01

    The dependence of ablation rate of an Al alloy on laser beam spot size (10–150 µm) was investigated using an ArF excimer laser operating at a wavelength of 193 nm and pulse width less than 4 ns. Ablation was conducted in air at a fluence of 11 J cm‑2 and at a repetition rate of 20 Hz. Surface morphology and depth of craters produced by a variable number of laser pulses were characterized using optical and scanning electron microscopy. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used as an additional diagnostic technique to estimate the amount of material ablated from craters produced by a laser beam of different diameters. Laser beam spot size and number of laser pulses applied to the same spot were found to influence crater morphology, ablation rate, shape and amount of particles deposited at or around the crater rim. Ablation rate was found to be less dependent on spot size for craters greater than 85 µm. A four-fold increase in ablation rate was observed with decreasing crater size from 150 µm to 10 µm.

  9. Depth Profiling of Polymer Composites by Ultrafast Laser Ablation

    NASA Astrophysics Data System (ADS)

    Young, Christopher; Clayton, Clive; Longtin, Jon

    2009-03-01

    Past work has shown femtosecond laser ablation to be an athermal process at low fluences in polymer systems. The ablation rate in this low fluence regime is very low, allowing for micro-scale removal of material. We have taken advantage of this fact to perform shallow depth profiling ablation on carbon fiber reinforced polymer (CFRP) composites. Neat composite and resin samples were studied to establish reference ablation profiles. These profiles and the effects of the heterogeneous distribution of carbon fibers were observed through confocal laser profilometry and optical and scanning electron microscopy. Weathered materials that have been subjected to accelerated tests in artificial sunlight or water conditions were ablated to determine the correlation between exposure and change in ablation characteristics. Preliminary Raman and micro-ATR analysis performed before and after ablation shows no chemical changes indicative of thermal effects. The low-volume-ablation property was utilized in an attempt to expose the sizing-matrix interphase for analysis.

  10. Radiofrequency catheter ablation in pediatric patients with supraventricular arrhythmias.

    PubMed

    Rhodes, L A; Lobban, J H; Schmidt, S B

    1995-01-01

    Radiofrequency (RF) ablation of foci leading to abnormal cardiac rhythms is rapidly becoming the procedure of choice in the management of arrhythmias in adults. This report reviews our initial experience with RF ablation in the pediatric population. PMID:8533398

  11. Specific Impulse Definition for Ablative Laser Propulsion

    NASA Astrophysics Data System (ADS)

    Gregory, Don A.; Herren, Kenneth A.

    2005-04-01

    The term "specific impulse" is so ingrained in the field of rocket propulsion that it is unlikely that any fundamental argument would be taken seriously for its removal. It is not an ideal measure but it does give an indication of the amount of mass flow (mass loss/time), as in fuel rate, required to produce a measured thrust over some time period. This investigation explores the implications of being able to accurately measure the ablation rate and how the language used to describe the specific impulse results may have to change slightly, and recasts the specific impulse as something that is not a time average. It is not currently possible to measure the ablation rate accurately in real time so it is generally just assumed that a constant amount of material will be removed for each laser pulse delivered. The specific impulse dependence on the ablation rate is determined here as a correction to the classical textbook definition.

  12. Simulation of Double-Pulse Laser Ablation

    SciTech Connect

    Povarnitsyn, Mikhail E.; Khishchenko, Konstantin V.; Levashov, Pavel R.; Itina, Tatian E.

    2010-10-08

    We investigate the physical reasons of a strange decrease in the ablation depth observed in femtosecond double-pulse experiments with increasing delay between the pulses. Two ultrashort pulses of the same energy produce the crater which is less than that created by a single pulse. Hydrodynamic simulation shows that the ablation mechanism is suppressed when the delay between the pulses exceeds the electron-ion relaxation time. In this case, the interaction of the second laser pulse with the expanding target material leads to the formation of the second shock wave suppressing the rarefaction wave created by the first pulse. The modeling of the double-pulse ablation for different delays between pulses confirms this explanation.

  13. Numerical Modeling of Ablation Heat Transfer

    NASA Technical Reports Server (NTRS)

    Ewing, Mark E.; Laker, Travis S.; Walker, David T.

    2013-01-01

    A unique numerical method has been developed for solving one-dimensional ablation heat transfer problems. This paper provides a comprehensive description of the method, along with detailed derivations of the governing equations. This methodology supports solutions for traditional ablation modeling including such effects as heat transfer, material decomposition, pyrolysis gas permeation and heat exchange, and thermochemical surface erosion. The numerical scheme utilizes a control-volume approach with a variable grid to account for surface movement. This method directly supports implementation of nontraditional models such as material swelling and mechanical erosion, extending capabilities for modeling complex ablation phenomena. Verifications of the numerical implementation are provided using analytical solutions, code comparisons, and the method of manufactured solutions. These verifications are used to demonstrate solution accuracy and proper error convergence rates. A simple demonstration of a mechanical erosion (spallation) model is also provided to illustrate the unique capabilities of the method.

  14. Performance of Conformable Ablators in Aerothermal Environments

    NASA Technical Reports Server (NTRS)

    Thornton, J.; Fan, W.; Skokova, K.; Stackpoole, M.; Beck, R.; Chavez-Garcia, J.

    2012-01-01

    Conformable Phenolic Impregnated Carbon Ablator, a cousin of Phenolic Impregnated Carbon Ablator (PICA), was developed at NASA Ames Research Center as a lightweight thermal protection system under the Fundamental Aeronautics Program. PICA is made using a brittle carbon substrate, which has a very low strain to failure. Conformable PICA is made using a flexible carbon substrate, a felt in this case. The flexible felt significantly increases the strain to failure of the ablator. PICA is limited by its thermal mechanical properties. Future NASA missions will require heatshields that are more fracture resistant than PICA and, as a result, NASA Ames is working to improve PICAs performance by developing conformable PICA to meet these needs. Research efforts include tailoring the chemistry of conformable PICA with varying amounts of additives to enhance mechanical properties and testing them in aerothermal environments. This poster shows the performance of conformable PICA variants in arc jets tests. Some mechanical and thermal properties will also be presented.

  15. Deep Dive Topic: Choosing between ablators

    SciTech Connect

    Hurricane, O. A.; Thomas, C.; Olson, R.

    2015-07-14

    Recent data on implosions using identical hohlraums and very similar laser drives underscores the conundrum of making a clear choice of one ablator over another. Table I shows a comparison of Be and CH in a nominal length, gold, 575 μm-diameter, 1.6 mg/cc He gas-fill hohlraum while Table II shows a comparison of undoped HDC and CH in a +700 length, gold, 575 μm diameter, 1.6 mg/cc He gas fill hohlraum. As can be seen in the tables, the net integrated fusion performance of these ablators is the same to within error bars. In the case of the undoped HDC and CH ablators, the hot spot shapes of the implosions were nearly indistinguishable for the experiments listed in Table II.

  16. Effects of endocardial microwave energy ablation

    PubMed Central

    Climent, Vicente; Hurlé, Aquilino; Ho, Siew Yen; Sánchez-Quintana, Damián

    2005-01-01

    Until recently the treatment of atrial fibrillation (AF) consisted primarily of palliation, mostly in the form of pharmacological intervention. However because of recent advances in nonpharmacologic therapies, the current expectation of patients and referring physicians is that AF will be cured, rather than palliated. In recent years there has been a rapid expansion in the availability and variety of energy sources and devices for ablation. One of these energies, microwave, has been applied clinically only in the last few years, and may be a promising technique that is potentially capable of treating a wide range of ventricular and supraventricular arrhythmias. The purpose of this study was to review microwave energy ablation in surgical treatment of AF with special interest in histology and ultrastructure of lesions produced by this endocardial ablation procedure. PMID:16943871

  17. Laser ablated hard coating for microtools

    DOEpatents

    McLean, W. II; Balooch, M.; Siekhaus, W.J.

    1998-05-05

    Wear-resistant coatings composed of laser ablated hard carbon films, are deposited by pulsed laser ablation using visible light, on instruments such as microscope tips and micro-surgical tools. Hard carbon, known as diamond-like carbon (DLC), films produced by pulsed laser ablation using visible light enhances the abrasion resistance, wear characteristics, and lifetimes of small tools or instruments, such as small, sharp silicon tips used in atomic probe microscopy without significantly affecting the sharpness or size of these devices. For example, a 10--20 nm layer of diamond-like carbon on a standard silicon atomic force microscope (AFM) tip, enables the useful operating life of the tip to be increased by at least twofold. Moreover, the low inherent friction coefficient of the DLC coating leads to higher resolution for AFM tips operating in the contact mode. 12 figs.

  18. Laser ablated hard coating for microtools

    DOEpatents

    McLean, II, William; Balooch, Mehdi; Siekhaus, Wigbert J.

    1998-05-05

    Wear-resistant coatings composed of laser ablated hard carbon films, are deposited by pulsed laser ablation using visible light, on instruments such as microscope tips and micro-surgical tools. Hard carbon, known as diamond-like carbon (DLC), films produced by pulsed laser ablation using visible light enhances the abrasion resistance, wear characteristics, and lifetimes of small tools or instruments, such as small, sharp silicon tips used in atomic probe microscopy without significantly affecting the sharpness or size of these devices. For example, a 10-20 nm layer of diamond-like carbon on a standard silicon atomic force microscope (AFM) tip, enables the useful operating life of the tip to be increased by at least twofold. Moreover, the low inherent friction coefficient of the DLC coating leads to higher resolution for AFM tips operating in the contact mode.

  19. Specific Impulse Definition for Ablative Laser Propulsion

    NASA Technical Reports Server (NTRS)

    Herren, Kenneth A.; Gregory, Don A.

    2004-01-01

    The term "specific impulse" is so ingrained in the field of rocket propulsion that it is unlikely that any fundamental argument would be taken seriously for its removal. It is not an ideal measure but it does give an indication of the amount of mass flow (mass loss/time), as in fuel rate, required to produce a measured thrust over some time period This investigation explores the implications of being able to accurately measure the ablation rate and how the language used to describe the specific impulse results may have to change slightly, and recasts the specific impulse as something that is not a time average. It is not currently possible to measure the ablation rate accurately in real time so it is generally just assumed that a constant amount of material will be removed for each laser pulse delivered The specific impulse dependence on the ablation rate is determined here as a correction to the classical textbook definition.

  20. Ablation therapy for left atrial autonomic modification.

    PubMed

    Malcolme-Lawes, Louisa; Sandler, Belinda C; Sikkel, Markus B; Lim, Phang Boon; Kanagaratnam, Prapa

    2016-08-01

    The autonomic nervous system is implicated in the multifactorial pathogenesis of atrial fibrillation (AF) but few studies have attempted neural targeting for therapeutic intervention. We have demonstrated that short bursts of stimulation, at specific sites of left atrial ganglionated plexi (GPs), trigger fibrillation-inducing atrial ectopy and importantly continuous stimulation of these sites may not induce AV block, the 'conventional' marker used to locate GPs. We have shown that these ectopy-triggering GP (ET-GP) sites are anatomically stable and can be rendered inactive by either ablation at the site or by ablation between the site and the adjacent pulmonary vein (PV). This may have important implications for planning patient specific strategies for ablation of paroxysmal AF in the future. PMID:27595199

  1. Ultrafast laser ablation of transparent materials

    NASA Astrophysics Data System (ADS)

    Bauer, Lara; Russ, Simone; Kaiser, Myriam; Kumkar, Malte; Faißt, Birgit; Weber, Rudolf; Graf, Thomas

    2016-03-01

    The present work investigates the influence of the pulse duration and the temporal spacing between pulses on the ablation of aluminosilicate glass by comparing the results obtained with pulse durations of 0.4 ps and 6 ps. We found that surface modifications occur already at fluences below the single pulse ablation threshold and that laser-induced periodic surface structures (LIPSS) emerge as a result of those surface modifications. For 0.4 ps the ablation threshold fluences is lower than for 6 ps. Scanning electron micrographs of LIPSS generated with 0.4 ps exhibit a more periodic and less coarse structure as compared to structures generated with 6 ps. Furthermore we report on the influence of temporal spacing between the pulses on the occurrence of LIPSS and the impact on the quality of the cutting edge. Keywords: LIPSS,

  2. Tumor Ablation: Common Modalities and General Practices

    PubMed Central

    Knavel, Erica M.; Brace, Christopher L.

    2014-01-01

    Tumor ablation is a minimally invasive technique that is commonly used in the treatment of tumors of the liver, kidney, bone, and lung. During tumor ablation, thermal energy is used to heat or cool tissue to cytotoxic levels (less than −40°C or more than 60°C). An additional technique is being developed that targets the permeability of the cell membrane and is ostensibly nonthermal. Within the classification of tumor ablation, there are several modalities used worldwide: radiofrequency, microwave, laser, high-intensity focused ultrasound, cryoablation, and irreversible electroporation. Each technique, although similar in purpose, has specific and optimal indications. This review serves to discuss general principles and technique, reviews each modality, and discusses modality selection. PMID:24238374

  3. Thermal Ablation Modeling for Silicate Materials

    NASA Technical Reports Server (NTRS)

    Chen, Yih-Kanq

    2016-01-01

    A thermal ablation model for silicates is proposed. The model includes the mass losses through the balance between evaporation and condensation, and through the moving molten layer driven by surface shear force and pressure gradient. This model can be applied in ablation simulations of the meteoroid or glassy Thermal Protection Systems for spacecraft. Time-dependent axi-symmetric computations are performed by coupling the fluid dynamics code, Data-Parallel Line Relaxation program, with the material response code, Two-dimensional Implicit Thermal Ablation simulation program, to predict the mass lost rates and shape change. For model validation, the surface recession of fused amorphous quartz rod is computed, and the recession predictions reasonably agree with available data. The present parametric studies for two groups of meteoroid earth entry conditions indicate that the mass loss through moving molten layer is negligibly small for heat-flux conditions at around 1 MW/cm(exp. 2).

  4. Body Buffer Zone and Proxemics in Blocking.

    ERIC Educational Resources Information Center

    Stockwell, John C.; Bahs, Clarence W.

    This paper investigates the effect of personal body buffer zones on compositional arrangements staged by novice directors. Relationships between directors' concepts of personal space and their projection of its dimensions into staging are studied through the use of a variety of proximity measures--distance, area angles of approach, and physical…

  5. FED. Zoning for TRUMP Heat Transfer Code

    SciTech Connect

    Elrod, D.

    1987-10-23

    FED reduces the effort required to obtain the necessary geometric input for problems which are to be solved using the heat-transfer code, TRUMP. TRUMP calculates transient and steady-state temperature distributions in multidimensional systems. FED can properly zone any body of revolution in one, two, or three dimensions.

  6. Determination of cytotoxic thermal dose during HIFU ablation

    NASA Astrophysics Data System (ADS)

    Nandlall, Sacha D.; Bazán-Peregrino, Miriam; Mo, Steven; Coussios, Constantin-C.

    2012-10-01

    Thermal dose has been proposed for various hyperthermic cancer treatment modalities as a measure of heat-induced cell and tissue damage. However, many of the models that are currently used for calculating thermal dose have not been validated or suitably adapted for the elevated temperatures and rates of heating encountered during ablation by High-Intensity Focused Ultrasound (HIFU). This work quantifies the performance of the widely employed Cumulative Equivalent Minutes at 43°C (CEM43) thermal dose metric under HIFU-relevant heating. A total of 36 agar phantoms were embedded with different human cancer cell lines (PC3, 22RV1, or ZR75.1) as well as calcein AM and propidium iodide assays. The phantoms were cast in sterile molds with internal dimensions of 7 cm × 7 cm × 2 mm. Using a water bath, 12 of the phantoms were treated with mild hyperthermia (43-46°C for up to 60 minutes), while another 12 were subjected to HIFU-relevant temperature profiles (60-80°C peak temperature, 2-3°C/s peak heating rate). In each of the remaining 12 phantoms, 8 HIFU exposures were carried out in a 37°C water tank (1.067 MHz, 95% duty cycle, 3-6 MPa peak rarefaction pressure, 2-20 s exposure duration). Cavitation emissions were monitored passively with a detector transducer that was confocally and co-axially aligned with the HIFU source. Cell death was quantified by measuring the locally averaged fluorescence intensity of the assays relative to unheated and severely heat-shocked phantoms. The results show that the CEM43 dose required to achieve the same level of heat-induced cell death varies considerably across cell lines, and that inertial cavitation can cause significant mechanical damage at ablation-relevant intensities even when no significant thermal dose is delivered (CEM43 < 5 s). These findings demonstrate the need for improved models of cell death at ablation-relevant temperatures.

  7. Indirect-drive ablative Richtmyer Meshkov node scaling

    NASA Astrophysics Data System (ADS)

    Landen, O. L.; Baker, K. L.; Clark, D. S.; Goncharov, V. N.; Hammel, B. A.; Ho, D. D.; Hurricane, O. A.; Lindl, J. D.; Loomis, E. N.; Masse, L.; Mauche, C.; Milovich, J. L.; Peterson, J. L.; Smalyuk, V. A.; Yi, S. A.; Velikovich, A. L.; Weber, C.

    2016-05-01

    The ablation front Rayleigh Taylor hydroinstability growth dispersion curve for indirect-drive implosions has been shown to be dependent on the Richtmyer Meshkov growth during the first shock transit phase. In this paper, a simplified treatment of the first shock ablative Richtmyer-Meshkov (ARM) growth dispersion curve is used to extract differences in ablation front perturbation growth behavior as function of foot pulse shape and ablator material for comparing the merits of various ICF design option.

  8. Stereotactic Body Radiotherapy and Ablative Therapies for Lung Cancer.

    PubMed

    Abbas, Ghulam; Danish, Adnan; Krasna, Mark J

    2016-07-01

    The treatment paradigm for early stage lung cancer and oligometastatic disease to the lung is rapidly changing. Ablative therapies, especially stereotactic body radiation therapy, are challenging the surgical gold standard and have the potential to be the standard for operable patients with early stage lung cancer who are high risk due to co- morbidities. The most commonly used ablative modalities include stereotactic body radiation therapy, microwave ablation, and radiofrequency ablation. PMID:27261915

  9. Stereotactic Body Radiotherapy and Ablative Therapies for Lung Cancer.

    PubMed

    Abbas, Ghulam; Danish, Adnan; Krasna, Mark J

    2016-07-01

    The treatment paradigm for early stage lung cancer and oligometastatic disease to the lung is rapidly changing. Ablative therapies, especially stereotactic body radiation therapy, are challenging the surgical gold standard and have the potential to be the standard for operable patients with early stage lung cancer who are high risk due to co- morbidities. The most commonly used ablative modalities include stereotactic body radiation therapy, microwave ablation, and radiofrequency ablation.

  10. Thermal Ablation for Benign Thyroid Nodules: Radiofrequency and Laser

    PubMed Central

    Lee, Jeong Hyun; Valcavi, Roberto; Pacella, Claudio M.; Rhim, Hyunchul; Na, Dong Gyu

    2011-01-01

    Although ethanol ablation has been successfully used to treat cystic thyroid nodules, this procedure is less effective when the thyroid nodules are solid. Radiofrequency (RF) ablation, a newer procedure used to treat malignant liver tumors, has been valuable in the treatment of benign thyroid nodules regardless of the extent of the solid component. This article reviews the basic physics, techniques, applications, results, and complications of thyroid RF ablation, in comparison to laser ablation. PMID:21927553

  11. Subcellular analysis by laser ablation electrospray ionization mass spectrometry

    DOEpatents

    Vertes, Akos; Stolee, Jessica A; Shrestha, Bindesh

    2014-12-02

    In various embodiments, a method of laser ablation electrospray ionization mass spectrometry (LAESI-MS) may generally comprise micro-dissecting a cell comprising at least one of a cell wall and a cell membrane to expose at least one subcellular component therein, ablating the at least one subcellular component by an infrared laser pulse to form an ablation plume, intercepting the ablation plume by an electrospray plume to form ions, and detecting the ions by mass spectrometry.

  12. Percutaneous Ablation for Small Renal Masses—Imaging Follow-Up

    PubMed Central

    Iannuccilli, Jason D.; Grand, David J.; Dupuy, Damian E.; Mayo-Smith, William W.

    2014-01-01

    Image-guided percutaneous thermal ablation is a safe and effective nephron-sparing alternative to surgical resection for the treatment of small renal tumors. Assessment of treatment efficacy relies heavily on interval follow-up imaging after treatment. Contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) both play a pivotal role in evaluating the treatment zone, identifying residual tumor, and detecting early and delayed procedure-related complications. This article discusses a surveillance imaging protocol for patients who undergo percutaneous thermal ablation of renal tumors, and also illustrates the typical appearances of both successfully treated tumors and residual disease on contrast-enhanced CT or MRI. In addition, it discusses the imaging appearance of potential early and delayed treatment-related complications to facilitate their prompt detection and management. PMID:24596440

  13. Dimensioning, Tolerancing, and Machine Finishes.

    ERIC Educational Resources Information Center

    Adams, George C.

    Intended for use with the vocational education student interested in technical drawing, this guide provides answers to questions relating to dimensioning and tolerancing machine drawings. It also gives examples of standard dimensioning practices, tolerancing applications, and finish applications. The problems and examples presented are based on…

  14. Dimensions of Organizational Task Environments.

    ERIC Educational Resources Information Center

    Dess, Gregory G.; Beard, Donald W.

    1984-01-01

    Reducing Aldrich's codification of organizational task environments from six to three dimensions--munificence (capacity), complexity (homogeneity-heterogeneity, concentration-dispersion), and dynamism (stability-instability, turbulence), the authors use interim and factor analytical techniques to explore each dimension's viability and draw…

  15. Dimensions of temperament: an analysis.

    PubMed

    Lorr, M; Stefic, E C

    1976-01-01

    The TDOT recast into a single stimulus format was administered to 150 college Ss. A factor analysis of the items followed by an analysis of item clusters that define each factor indicated the presence of 14 dimensions. Of the 10 bipolar scales of the TDOT, 3 were confirmed as independent dimensions, and 5 were confirmed in part or split into unipolar factors.

  16. High throughput solar cell ablation system

    SciTech Connect

    Harley, Gabriel; Pass, Thomas; Cousins, Peter John; Viatella, John

    2014-10-14

    A solar cell is formed using a solar cell ablation system. The ablation system includes a single laser source and several laser scanners. The laser scanners include a master laser scanner, with the rest of the laser scanners being slaved to the master laser scanner. A laser beam from the laser source is split into several laser beams, with the laser beams being scanned onto corresponding wafers using the laser scanners in accordance with one or more patterns. The laser beams may be scanned on the wafers using the same or different power levels of the laser source.

  17. Effects of Laser Wavelength on Ablator Testing

    NASA Technical Reports Server (NTRS)

    White, Susan M.

    2014-01-01

    Wavelength-dependent or spectral radiation effects are potentially significant for thermal protection materials. NASA atmospheric entry simulations include trajectories with significant levels of shock layer radiation which is concentrated in narrow spectral lines. Tests using two different high powered lasers, the 10.6 micron LHMEL I CO2 laser and the near-infrared 1.07 micron fiber laser, on low density ablative thermal protection materials offer a unique opportunity to evaluate spectral effects. Test results indicated that the laser wavelength can impact the thermal response of an ablative material, in terms of bond-line temperatures, penetration times, mass losses, and char layer thicknesses.

  18. Testing of Advanced Conformal Ablative TPS

    NASA Technical Reports Server (NTRS)

    Gasch, Matthew; Agrawal, Parul; Beck, Robin

    2013-01-01

    In support of the CA250 project, this paper details the results of a test campaign that was conducted at the Ames Arcjet Facility, wherein several novel low density thermal protection (TPS) materials were evaluated in an entry like environment. The motivation for these tests was to investigate whether novel conformal ablative TPS materials can perform under high heat flux and shear environment as a viable alternative to rigid ablators like PICA or Avcoat for missions like MSL and beyond. A conformable TPS over a rigid aeroshell has the potential to solve a number of challenges faced by traditional rigid TPS materials (such as tiled Phenolic Impregnated Carbon Ablator (PICA) system on MSL, and honeycomb-based Avcoat on the Orion Multi Purpose Crew Vehicle (MPCV)). The compliant (high strain to failure) nature of the conformable ablative materials will allow better integration of the TPS with the underlying aeroshell structure and enable monolithic-like configuration and larger segments to be used in fabrication.A novel SPRITE1 architecture, developed by the researchers at NASA Ames was used for arcjet testing. This small probe like configuration with 450 spherecone, enabled us to test the materials in a combination of high heat flux, pressure and shear environment. The heat flux near the nose were in the range of 500-1000 W/sq cm whereas in the flank section of the test article the magnitudes were about 50 of the nose, 250-500W/sq cm range. There were two candidate conformable materials under consideration for this test series. Both test materials are low density (0.28 g/cu cm) similar to Phenolic Impregnated Carbon Ablator (PICA) or Silicone Impregnated Refractory Ceramic Ablator (SIRCA) and are comprised of: A flexible carbon substrate (Carbon felt) infiltrated with an ablative resin system: phenolic (Conformal-PICA) or silicone (Conformal-SICA). The test demonstrated a successful performance of both the conformable ablators for heat flux conditions between 50

  19. General Model for Multicomponent Ablation Thermochemistry

    NASA Technical Reports Server (NTRS)

    Milos, Frank S.; Marschall, Jochen; Rasky, Daniel J. (Technical Monitor)

    1994-01-01

    A previous paper (AIAA 94-2042) presented equations and numerical procedures for modeling the thermochemical ablation and pyrolysis of thermal protection materials which contain multiple surface species. This work describes modifications and enhancements to the Multicomponent Ablation Thermochemistry (MAT) theory and code for application to the general case which includes surface area constraints, rate limited surface reactions, and non-thermochemical mass loss (failure). Detailed results and comparisons with data are presented for the Shuttle Orbiter reinforced carbon-carbon oxidation protection system which contains a mixture of sodium silicate (Na2SiO3), silica (SiO2), silicon carbide (SiC), and carbon (C).

  20. A Sensor for Obtaining Ablation Rates

    NASA Technical Reports Server (NTRS)

    Winters, Clyde W.; Bracalente, Emedio

    1961-01-01

    A variable-capacitance ablation-rate sensor which allows continuous measurements of ablation rates for Teflon and similar polymers has been developed and tested i n an ethylene-heated high-temperature jet at stagnation temperatures ranging from 2,400 deg to 3,800 deg F. The data (length changes) were measured by using the same telemeter equipment as that used in rocket-propelled flight vehicles.Results indicate measurement error to be a maximum of 4 percent between the telemetered length changes and the length changes that were obtained from photographic records of the test.

  1. High throughput solar cell ablation system

    SciTech Connect

    Harley, Gabriel; Pass, Thomas; Cousins, Peter John; Viatella, John

    2012-09-11

    A solar cell is formed using a solar cell ablation system. The ablation system includes a single laser source and several laser scanners. The laser scanners include a master laser scanner, with the rest of the laser scanners being slaved to the master laser scanner. A laser beam from the laser source is split into several laser beams, with the laser beams being scanned onto corresponding wafers using the laser scanners in accordance with one or more patterns. The laser beams may be scanned on the wafers using the same or different power levels of the laser source.

  2. Dispersive effects in laser ablation plasmas

    NASA Astrophysics Data System (ADS)

    Irimiciuc, Ştefan Andrei; Agop, Maricel; Nica, Petru; Gurlui, Silviu; Mihăileanu, Doina; Toma, Ştefan; Focşa, Cristian

    2014-11-01

    The dynamics of transient plasmas generated by high-fluence nanosecond laser ablation has been investigated by recording the ionic current with a Langmuir probe. Systematic measurements have been carried out on a plasma produced in vacuum by Nd:YAG laser irradiation of a copper target. The temporal evolution of the ionic current for different fluences was investigated, revealing the presence of some periodic oscillations. A theoretical model is proposed in order to describe the nonlinear behavior of the expanding plasma by assuming that the motion curves of the ablated particles are fractals. The behaviors predicted by the proposed theoretical model are in good agreement with the experimental findings.

  3. Photothermal ablation of liver tissue with 1940-nm thulium fiber laser: an ex vivo study on lamb liver

    NASA Astrophysics Data System (ADS)

    Alagha, Heba Z.; Gülsoy, Murat

    2016-01-01

    The purpose of this study was to investigate the ablation efficiency of 1940-nm thulium fiber laser on liver tissue, while utilizing a real-time measurement system to monitor the temperature rise in adjacent tissues. Thulium fiber laser was delivered to lamb liver tissue samples via 400-μm bare tip fiber in contact mode. Eight different laser parameter combinations [power, continuous-wave (cw)/pulsed-modulated (pm) mode, and exposure time] were used. Exposure times were chosen to give the same total applied energy of 4 J for comparative purposes. Following laser irradiations, tissues were processed and stained with hematoxylin and eosin for macroscopic evaluation of ablation areas and total altered areas, and ablation efficiencies were calculated. Temperature of the nearby tissue at a distance of 1 mm from the fiber was measured, and rate of temperature change was calculated. A strong correlation between the rate of temperature change and ablation area was noted. Thermal effects increased with increasing power for both modes. The continuous-wave mode yielded higher ablation efficiencies than the pulse-modulated mode. Histological evaluation revealed a narrow vacuolization zone and negligible carbonization for higher-power values.

  4. Experimental measurement of ablation effects in plasma armature railguns

    SciTech Connect

    Parker, J.V.; Parsons, W.M.

    1986-01-01

    Experimental evidence supporting the importance of ablation in plasma armature railguns is presented. Experiments conducted using the HYVAX and MIDI-2 railguns are described. Several indirect effects of ablation are identified from the experimental results. An improved ablation model of plasma armature dynamics is proposed which incorporates the restrike process.

  5. Ablation techniques for primary and metastatic liver tumors

    PubMed Central

    Ryan, Michael J; Willatt, Jonathon; Majdalany, Bill S; Kielar, Ania Z; Chong, Suzanne; Ruma, Julie A; Pandya, Amit

    2016-01-01

    Ablative treatment methods have emerged as safe and effective therapies for patients with primary and secondary liver tumors who are not surgical candidates at the time of diagnosis. This article reviews the current literature and describes the techniques, complications and results for radiofrequency ablation, microwave ablation, cryoablation, and irreversible electroporation. PMID:26839642

  6. Distributed modeling of ablation (1996–2011) and climate sensitivity on the glaciers of Taylor Valley, Antarctica

    DOE PAGES

    Hoffman, Matthew J.; Fountain, Andrew G.; Liston, Glen E.

    2016-02-24

    Here, the McMurdo Dry Valleys of Antarctica host the coldest and driest ecosystem on Earth, which is acutely sensitive to the availability of water coming from glacial runoff. We modeled the spatial variability in ablation and assessed climate sensitivity of the glacier ablation zones using 16 years of meteorological and surface mass-balance observations collected in Taylor Valley. Sublimation was the primary form of mass loss over much of the ablation zones, except for near the termini where melt, primarily below the surface, dominated. Microclimates in ~10 m scale topographic basins generated melt rates up to ten times higher than overmore » smooth glacier surfaces. In contrast, the vertical terminal cliffs on the glaciers can have higher or lower melt rates than the horizontal surfaces due to differences in incoming solar radiation. The model systematically underpredicted ablation for the final 5 years studied, possibly due to an increase of windblown sediment. Surface mass-balance sensitivity to temperature was ~–0.02 m w.e. K–1, which is among the smallest magnitudes observed globally. We also identified a high sensitivity to ice albedo, with a decrease of 0.02 having similar effects as a 1 K increase in temperature, and a complex sensitivity to wind speed.« less

  7. Navier-Stokes analysis of scale effects on ablation in carbon-carbon rocket nozzles

    NASA Astrophysics Data System (ADS)

    Bianchi, D.; Nasuti, F.; Martelli, E.; Onofri, M.

    2012-01-01

    A study is conducted to predict carbon-carbon nozzle recession behavior in solid rocket motors (SRM) for wide variations of propellant formulations and motor operating conditions. The numerical model considers the solution of Reynolds averaged Navier-Stokes (RANS) equations in the nozzle, heterogeneous chemical reactions at the nozzle surface, variable transport and thermodynamic properties, and heat conduction in the nozzle material. Results show that the ablation rate is affected by the dimension of the nozzle as well as by the boundary layer thickness at the nozzle entrance. The combined effect of both scale and boundary layer thickness at the nozzle entrance is also analyzed.

  8. Selective nanoparticle-directed photothermal ablation of the canine prostate

    NASA Astrophysics Data System (ADS)

    Schwartz, Jon A.; Price, Roger E.; Gill-Sharp, Kelly L.; Sang, Krystina L.; Khorchani, Jennifer D.; Payne, J. Donald; Goodwin, Bradford S.

    2011-03-01

    This study adapted AuroLase® Therapy, previously reported for the treatment of brain tumors, to the treatment of prostate disease by 1) using normal canine prostate in vivo, directly injected with a solution of nanoparticles as a proxy for prostate tumor and, 2) developing an appropriate laser dosimetry for prostate which is which is subablative in native prostate while simultaneously producing photothermal coagulation in prostate tissue containing therapeutic nanoshells. Healthy, mixed-breed hound dogs were given surgical laparotomies during which nanoshells were injected directly into one or both prostate hemispheres. Laser energy was delivered percutaneously to the parenchyma of the prostate along 1-5 longitudinal tracts via a liquid-cooled optical fiber catheter terminated with a 1-cm isotropic diffuser after which the incision was closed and sutured using standard surgical techniques. The photothermal lesions were permitted to resolve for up to 8 days, after which each animal was euthanized, necropsied, and the prostate taken for histopathological analysis. We developed a laser dosimetry which is sub- to marginally ablative in native prostate and simultaneously ablative of prostate tissue containing nanoshells which would indicate a viable means of treating tumors of the prostate which are known from other studies to accumulate nanoshells. Secondly, we determined that multiple laser treatments of nanoshell-containing prostate tissue could be accomplished while sparing the urethra and prostate capsule thermal damage. Finally, we determined that the extent of damage zone radii correlate positively with nanoshell concentration, and negatively to the length of time between nanoshell injection and laser treatment.

  9. Organized Atrial Tachycardias after Atrial Fibrillation Ablation

    PubMed Central

    Castrejón-Castrejón, Sergio; Ortega, Marta; Pérez-Silva, Armando; Doiny, David; Estrada, Alejandro; Filgueiras, David; López-Sendón, José L.; Merino, José L.

    2011-01-01

    The efficacy of catheter-based ablation techniques to treat atrial fibrillation is limited not only by recurrences of this arrhythmia but also, and not less importantly, by new-onset organized atrial tachycardias. The incidence of such tachycardias depends on the type and duration of the baseline atrial fibrillation and specially on the ablation technique which was used during the index procedure. It has been repeatedly reported that the more extensive the left atrial surface ablated, the higher the incidence of organized atrial tachycardias. The exact origin of the pathologic substrate of these trachycardias is not fully understood and may result from the interaction between preexistent regions with abnormal electrical properties and the new ones resultant from radiofrequency delivery. From a clinical point of view these atrial tachycardias tend to remit after a variable time but in some cases are responsible for significant symptoms. A precise knowledge of the most frequent types of these arrhythmias, of their mechanisms and components is necessary for a thorough electrophysiologic characterization if a new ablation procedure is required. PMID:21941669

  10. Laboratory Micrometeroid/Dust Ablation Studies

    NASA Astrophysics Data System (ADS)

    Thomas, E.; Horanyi, M.; Janches, D.; Munsat, T. L.; Plane, J. M. C.; Simolka, J.; Sternovsky, Z.

    2014-12-01

    Each day, somewhere between 5-270 tonnes of meteoric material ablates in Earth's upper atmosphere. Thisenormous range is significant because the Interplanetary Dust Particle (IDP) input has implications in ourunderstanding of meteor transport in the atmosphere, the formation of layers of metal atoms and ions,nucleation of noctilucent clouds, effects on stratospheric aerosols and O3 chemistry, and dust evolution inour solar system. As the dust ablates, it produces light, as well as a plasma trail of ionized atmosphericatoms and electrons. These meteor signatures are detected by photographic means, or by radar, but thereremain uncertainties in the luminous efficiency and ionization coefficient of meteors - two parameters thatare essential to evaluate densities, masses, height distributions and fluxes. Precise measurements of theseparameters would allow for not only an understanding of the layers of metal atoms and ions and meteoricsmoke particles in the mesosphere and lower thermosphere, but also would allow for the Earth's atmosphereto be used as a dust detector to detect and characterize the dust environment in our solar system. This work discusses the preliminary results of the new dust ablation facility at the 3 MV hypervelocity dust accelerator at the Institute for Modeling Plasma, Atmospheres and Cosmic Dust (IMPACT) at the University of Colorado, which aims to characterize the ionization coefficient and luminous efficiency of ablating micrometeroids.

  11. UV laser ablation patterns in intraocular lenses

    NASA Astrophysics Data System (ADS)

    Lagiou, D. P.; Evangelatos, Ch.; Apostolopoulos, A.; Spyratou, E.; Bacharis, C.; Makropoulou, M.; Serafetinides, A. A.

    2013-03-01

    The aim of this work is to investigate the effect of UV solid state laser radiation on intraocular lens (IOL) polymer surfaces as an alternative method to conventional surface shaping techniques for IOLs customization. Laser ablation experiments were performed on PMMA plates and commercially available hydrophobic and hydrophilic acrylic IOLs with the 5th harmonic of a Q-switched Nd:YAG laser (λ=213 nm). Circular arrays of holes were drilled on the polymer surface, covering the centre and the peripheries of the IOL. The morphology of the ablated IOL surface was examined with a conventional optical microscope (Leitz GMBH Wetzlar) and with a scanning electron microscope (SEM, Fei - Innova Nanoscope) at various laser parameters. Quantitative measurements of ablation rates were performed with a contact profilometer (Dektak-150), in which a mechanical stylus scanned across the surface of gold-coated IOLs (after SEM imaging) to measure variationsF in surface height. Laser interaction with IOLs depends on optical and mechanical material properties, in addition to laser radiation parameters. The exact ablation mechanism is discussed. Some polymer materials, depending on their properties, are more susceptible to the photothermal mechanism than the photochemical one or vice versa. In summary, every IOL polymer exhibits specific attributes in its interaction with the 5th harmonic of Nd:YAG laser.

  12. Atmospheric Profile Imprint in Firewall Ablation Coefficient

    NASA Technical Reports Server (NTRS)

    Ceplecha, Z.; Pecina, P.

    1984-01-01

    A general formula which expresses the distance along the meteoric fireball trajectory 1 as a function of t is discussed. Differential equations which include the motion and ablation of a single nonfragmenting meteor body are presented. The importance of the atmospheric density profile in the meteor formula is emphasized.

  13. Ablation Resistant Zirconium and Hafnium Ceramics

    NASA Technical Reports Server (NTRS)

    Bull, Jeffrey (Inventor); White, Michael J. (Inventor); Kaufman, Larry (Inventor)

    1998-01-01

    High temperature ablation resistant ceramic composites have been made. These ceramics are composites of zirconium diboride and zirconium carbide with silicon carbide, hafnium diboride and hafnium carbide with silicon carbide and ceramic composites which contain mixed diborides and/or carbides of zirconium and hafnium. along with silicon carbide.

  14. Combining Electrolysis and Electroporation for Tissue Ablation.

    PubMed

    Phillips, Mary; Rubinsky, Liel; Meir, Arie; Raju, Narayan; Rubinsky, Boris

    2015-08-01

    Electrolytic ablation is a method that operates by delivering low magnitude direct current to the target region over long periods of time, generating electrolytic products that destroy cells. This study was designed to explore the hypothesis stating that electrolytic ablation can be made more effective when the electrolysis-producing electric charges are delivered using electric pulses with field strength typical in reversible electroporation protocols. (For brevity we will refer to tissue ablation protocols that combine electroporation and electrolysis as E(2).) The mechanistic explanation of this hypothesis is related to the idea that products of electrolysis generated by E(2) protocols can gain access to the interior of the cell through the electroporation permeabilized cell membrane and therefore cause more effective cell death than from the exterior of an intact cell. The goal of this study is to provide a first-order examination of this hypothesis by comparing the charge dosage required to cause a comparable level of damage to a rat liver, in vivo, when using either conventional electrolysis or E(2) approaches. Our results show that E(2) protocols produce tissue damage that is consistent with electrolytic ablation. Furthermore, E(2) protocols cause damage comparable to that produced by conventional electrolytic protocols while delivering orders of magnitude less charge to the target tissue over much shorter periods of time.

  15. Modeling sublimation of a charring ablator

    NASA Technical Reports Server (NTRS)

    Balhoff, J. F.; Pike, R. W.

    1973-01-01

    The Hertz-Knudsen analysis is shown to accurately predict the sublimation rate from a charring ablator. Porosity is shown to have a significant effect on the surface temperature. The predominant carbon species found in the vapor is C3, which agrees well with the results of previous investigations.

  16. Innovative Laser Ablation Technology for Surface Decontamination

    SciTech Connect

    Chen, Winston C. H.

    2003-06-01

    The objective of this project is to develop a novel laser ablation in liquid for surface decontamination. It aims to achieve more efficient surface decontamination without secondary contamination. Another aim is to make this surface decontamination technology becomes economically feasible for large scale decontamination.

  17. Reflecting ablating heat shields for planetary entry.

    NASA Technical Reports Server (NTRS)

    Peterson, D. L.; Nachtsheim, P. R.; Howe, J. T.

    1972-01-01

    Heat shielding for planetary entry probes of future Jovian and Venusian missions will encounter heating levels well beyond those previously experienced. These entries are typically dominated by radiative heating from the shock layer. This paper demonstrates the potential of reflecting this incident radiation diffusely from an ablating material. This technique contrasts with the absorption experienced by char-forming or graphitic ablators. Two dielectric materials, Teflon (polytetra-fluoroethylene) and boron nitride, are examined for their ablative performance, including reflection, in a combined convective- and radiative-heating environment. For Teflon, at the conditions obtained, superimposition of radiative heating upon a convective stream causes no additional increase in surface recession over the convective only results. For boron nitride, an excellent room-temperature reflector in the visible spectrum, a decrease in reflectivity from 90 to 55 percent is experienced when the surface undergoes sublimation at high temperatures. The process of reflection in each of these materials is described in terms of backscattering from crystals. The significance of a sizable reflection as a mode of energy accommodation is demonstrated for Venusian entries as a potential reduction in mass loss due to ablation.

  18. Intumescent-ablator coatings using endothermic fillers

    NASA Technical Reports Server (NTRS)

    Sawko, P. M.; Riccitiello, S. R. (Inventor)

    1978-01-01

    An intumescent-ablator coating composition which contains the ammonium salt of 1,4-nitroaniline-2-sulfonic acid or 4,4 dinitrosul fanilide, a polymeric binder system and about 5 to 30% weight of an endothermic filler is reported. The filler has a decomposition temperature about or within the exothermic region of the intumescent agent.

  19. Plume collimation for laser ablation electrospray ionization mass spectrometry

    DOEpatents

    Vertes, Akos; Stolee, Jessica A.

    2016-06-07

    In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

  20. Plume collimation for laser ablation electrospray ionization mass spectrometry

    SciTech Connect

    Vertes, Akos; Stolee, Jessica A.

    2014-09-09

    In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

  1. Thermochemical Ablation Analysis of the Orion Heatshield

    NASA Technical Reports Server (NTRS)

    Sixel, William

    2015-01-01

    The Orion Multi-Purpose Crew Vehicle will one day carry astronauts to the Moon and beyond, and Orion's heatshield is a critical component in ensuring their safe return to Earth. The Orion heatshield is the structural component responsible for absorbing the intense heating environment caused by re-entry to Earth's atmosphere. The heatshield is primarily composed of Avcoat, an ablative material that is consumed during the re-entry process. Ablation is primarily characterized by two processes: pyrolysis and recession. The decomposition of in-depth virgin material is known as pyrolysis. Recession occurs when the exposed surface of the heatshield reacts with the surrounding flow. The Orion heatshield design was changed from an individually filled Avcoat honeycomb to a molded block Avcoat design. The molded block Avcoat heatshield relies on an adhesive bond to keep it attached to the capsule. In some locations on the heatshield, the integrity of the adhesive bond cannot be verified. For these locations, a mechanical retention device was proposed. Avcoat ablation was modelled in CHAR and the in-depth virgin material temperatures were used in a Thermal Desktop model of the mechanical retention device. The retention device was analyzed and shown to cause a large increase in the maximum bondline temperature. In order to study the impact of individual ablation modelling parameters on the heatshield sizing process, a Monte Carlo simulation of the sizing process was proposed. The simulation will give the sensitivity of the ablation model to each of its input parameters. As part of the Monte Carlo simulation, statistical uncertainties on material properties were required for Avcoat. Several properties were difficult to acquire uncertainties for: the pyrolysis gas enthalpy, non-dimensional mass loss rate (B´c), and Arrhenius equation parameters. Variability in the elemental composition of Avcoat was used as the basis for determining the statistical uncertainty in pyrolysis gas

  2. Laser ablation of a platinum target in water. I. Ablation mechanisms

    SciTech Connect

    Nichols, William T.; Sasaki, Takeshi; Koshizaki, Naoto

    2006-12-01

    This is the first in a series of three papers aimed at better understanding the processes that lead to nanomaterial formation during laser ablation of solid targets in liquids. Here we study the variation of the target surface morphology versus laser fluence and wavelength in order to suggest an ablation mechanism. A key finding is that an explosive ablation mechanism is prominent for a wide range of laser fluences for all wavelengths tested. Interestingly, however, ultraviolet (355 nm) and infrared (1064 nm) wavelengths show characteristically different explosive behaviors. In the infrared case, numerous large craters with diameters around 20 {mu}m form at localized points within the laser irradiated area. In contrast, ultraviolet ablation results in a striking transition to nanoscale surface roughness across the entire irradiated area. This texture is attributed to spinodal decomposition at the molten target surface. We propose that the wavelength and fluence dependence of the ablation craters can be explained by the amount of energy absorbed in the target. The consequences of the ablation mechanism for nanomaterial synthesis are discussed.

  3. Nd:YAG laser cleaning of ablation debris from excimer-laser-ablated polyimide

    NASA Astrophysics Data System (ADS)

    Gu, Jianhui; Low, Jason; Lim, Puay K.; Lim, Pean

    2001-10-01

    In the processing of excimer laser ablation of nozzles on polyimide in air, both gases like CO2, CO and HCN and solid debris including C2 approximately C12 are produced in laser ablation area. In this paper, we reported for the first time a Nd:YAG laser cleaning of ablation debris generated in excimer laser ablation of polyimide. It demonstrated effective cleaning with the advantages of shortening cleaning cycle time and simplifying cleaning process. The laser used for the cleaning was a Q-switched and frequency doubled Nd:YAG laser with wavelength of 532 nm and repetition rate of 10 Hz. The laser cleaning effect was compared with conventional plasma ashing. AFM measurement showed that the Nd:YAG laser cleaning had no damage to the substrate. XPS results indicated that the polyimide surface cleaned with laser beam had a lower oxygen/carbon ratio than that of plasma ashing. The study shows that frequency doubled Nd:YAG laser cleaning is effective in ablation debris removal from excimer laser ablated polyimide.

  4. Ablation of Atrial Fibrillation: Patient Selection, Periprocedural Anticoagulation, Techniques, and Preventive Measures After Ablation.

    PubMed

    Link, Mark S; Haïssaguerre, Michel; Natale, Andrea

    2016-07-26

    Atrial fibrillation (AF) is the most common arrhythmia encountered by cardiologists and is a major cause of morbidity and mortality. Risk factors for AF include age, male sex, genetic predisposition, hypertension, diabetes mellitus, sleep apnea, obesity, excessive alcohol, smoking, hyperthyroidism, pulmonary disease, air pollution, heart failure, and possibly excessive exercise. The management of AF involves decisions about rate versus rhythm control. Asymptomatic patients are generally managed with rate control and anticoagulation. Symptomatic patients will desire rhythm control. Rhythm control options are either antiarrhythmic agents or ablation, with each having its own risks and benefits. Ablation of AF has evolved from a rare and complex procedure to a common electrophysiological technique. Selection of patients to undergo ablation is an important aspect of AF care. Patients with the highest success rates of ablation are those with normal structural hearts and paroxysmal AF, although those with congestive heart failure have the greatest potential benefit of the procedure. Although pulmonary vein isolation of any means/energy source is the approach generally agreed on for those with paroxysmal AF, optimal techniques for the ablation of nonparoxysmal AF are not yet clear. Anticoagulation reduces thromboembolic complications; the newer anticoagulants have eased management for both the patient and the cardiologist. Aggressive management of modifiable risk factors (hypertension, diabetes mellitus, sleep apnea, obesity, excessive alcohol, smoking, hyperthyroidism, pulmonary disease, air pollution, and possibly excessive exercise) after ablation reduces the odds of recurrent AF and is an important element of care. PMID:27462054

  5. Burn, freeze, or photo-ablate?: comparative symptom profile in Barrett's dysplasia patients undergoing endoscopic ablation

    NASA Astrophysics Data System (ADS)

    Gill, Kanwar Rupinder S.; Gross, Seth A.; Greenwald, Bruce D.; Hemminger, Lois L.; Wolfsen, Herbert C.

    2009-06-01

    Background: There are few data available comparing endoscopic ablation methods for Barrett's esophagus with high-grade dysplasia (BE-HGD). Objective: To determine differences in symptoms and complications associated with endoscopic ablation. Design: Prospective observational study. Setting: Two tertiary care centers in USA. Patients: Consecutive patients with BE-HGD Interventions: In this pilot study, symptoms profile data were collected for BE-HGD patients among 3 endoscopic ablation methods: porfimer sodium photodynamic therapy, radiofrequency ablation and low-pressure liquid nitrogen spray cryotherapy. Main Outcome Measurements: Symptom profiles and complications from the procedures were assessed 1-8 weeks after treatment. Results: Ten BE-HGD patients were treated with each ablation modality (30 patients total; 25 men, median age: 69 years (range 53-81). All procedures were performed in the clinic setting and none required subsequent hospitalization. The most common symptoms among all therapies were chest pain, dysphagia and odynophagia. More patients (n=8) in the porfimer sodium photodynamic therapy group reported weight loss compared to radio-frequency ablactation (n=2) and cryotherapy (n=0). Four patients in the porfimer sodium photodynamic therapy group developed phototoxicity requiring medical treatment. Strictures, each requiring a single dilation, were found in radiofrequency ablactation (n=1) and porfimer sodium photodynamic therapy (n=2) patients. Limitations: Small sample size, non-randomized study. Conclusions: These three endoscopic therapies are associated with different types and severity of post-ablation symptoms and complications.

  6. Major ablative procedures in orthopaedic surgery.

    PubMed

    Soucacos, P N; Dailiana, Z H; Beris, A E; Xenakis, T H; Malizos, K N; Chrisovitsinos, J

    1996-01-01

    In the presence of the notable progress in limb-sparing techniques afforded by the developments in microsurgery and musculoskeletal oncology, major ablative surgery of the extremities still remains a last-resort, yet powerful tool in managing patients with primary tumors in whom wide excision is not possible, as well as in cases with severe trauma to the limbs. During the last thirteen years, eight major ablative procedures were performed at the Department of Orthopaedic Surgery of the University of Ioannina Medical School. Seven out of the eight procedures were performed in patients with primary malignant tumors either because the anatomical location or multiple recurrences of the tumor did not allow removal by wide local excision or by amputation at a lower level. In one patient, the procedure was related to a severe, mangling trauma. Four illustrative cases of the eight major ablative procedures performed are reported to highlight the current indications of this rarely used, complex, and extensive surgery. The characteristic cases presented are: hemipelvectomy in a patient with chondrosarcoma of the pelvis, disarticulation of the hip in a patient with a malignant histiocytoma of the supracondylar area of the knee, forequarter amputation in a patient with a basal cell carcinoma of the axilla, and disarticulation of the shoulder in a patient with an incomplete nonviable amputation at the level of the shoulder girdle associated with severe damage to the brachial plexus and axillary artery. After a five to over a ten year follow-up, six of the eight patients who where subjected to major ablative procedures are doing well and are satisfactorily active. These cases reflect the dilemma that orthopaedic surgeons geons still face in selecting limb salvage or major ablative surgery in cases of aggressive malignant tumors to severe trauma. PMID:8771355

  7. Femtosecond laser ablation of brass in air and liquid media

    SciTech Connect

    Shaheen, M. E.; Gagnon, J. E.; Fryer, B. J.

    2013-06-07

    Laser ablation of brass in air, water, and ethanol was investigated using a femtosecond laser system operating at a wavelength of 785 nm and a pulse width less than 130 fs. Scanning electron and optical microscopy were used to study the efficiency and quality of laser ablation in the three ablation media at two different ablation modes. With a liquid layer thickness of 3 mm above the target, ablation rate was found to be higher in water and ethanol than in air. Ablation under water and ethanol showed cleaner surfaces and less debris re-deposition compared to ablation in air. In addition to spherical particles that are normally formed from re-solidified molten material, micro-scale particles with varying morphologies were observed scattered in the ablated structures (craters and grooves) when ablation was conducted under water. The presence of such particles indicates the presence of a non-thermal ablation mechanism that becomes more apparent when ablation is conducted under water.

  8. Silicon-Class Ablators for NIC Ignition Capsules

    NASA Astrophysics Data System (ADS)

    Ho, Darwin; Salmonson, Jay; Haan, Steve

    2012-10-01

    We present design studies using silicon-class ablators (i.e., Si, SiC, SiB6, and SiB14) for NIC ignition capsules. These types of ablators have several advantages in that they: (a) require no internal dopant layers and are robust to M-band radiation; (b) have smooth outer surfaces; (c) have stable fuel-ablator interface; and (d) have good 1-D performance. The major disadvantage for some of the ablators in this class is the relatively smaller ablation stabilization. Consequently, the ablator is more susceptible to breakup caused by RT instabilities. However, smoother outer surfaces on this class of ablators can reduce the effect of RT instabilities. 2-D simulations of SiC ablators show ignition failure despite smooth surfaces and good 1-D performance. But SiB6 and SiB14 ablators exhibit promising behaviors. SiB6 (SiB14) ablators have high 1-D ignition margin and high peak core hydrodynamic pressure 880 (900) Gbar. The ablation scale length for SiB6 is longer than that for SiC and for SiB14 is comparable to that of plastic. Therefore, we expect acceptable performance for SiB6 and less RT growth for SiB14. 2-D simulations are now in progress.

  9. Current Status of Thermal Ablation Treatments for Lung Malignancies

    PubMed Central

    Dupuy, Damian E.; Shulman, Maria

    2010-01-01

    About 75% of lung cancer patients are not surgical candidates, either due to advanced disease or medical comorbidities. Furthermore, conventional treatments that can be offered to these patients are beneficial only to a small percentage of them. Thermal ablation is a minimally invasive treatment that is commonly used in this group of patients, and which has shown promising results. Currently, the most widely used ablation techniques in the treatment of lung malignancies are radiofrequency ablation (RFA), microwave ablation, and cryoablation. Although the most studied technique is RFA, recent studies with microwave ablation and cryoablation have shown some advantages over RFA. This article reviews the application of thermal ablation in the thorax, including patient selection, basic aspects of procedure technique, imaging follow-up, treatment outcomes, and comparison of ablation techniques. PMID:22550366

  10. Laser ablation of micro-photonic structures for efficient light collection and distribution

    NASA Astrophysics Data System (ADS)

    Shang, Xiaobing; Desmet, Andres; De Smet, Jelle; Joshi, Pankaj; Cuypers, Dieter; Van Put, Steven; Van Steenberge, Geert; Vervaeke, Michael; Thienpont, Hugo; De Smet, Herbert

    2015-06-01

    In this work we report the fabrication of polymer micro-photonic gratings for use in liquid-crystal based actively tunable electro-optic components. The gratings are produced by moving the sample surface sideways across a perpendicularly impinging KrF excimer laser beam (λ  =  248 nm), which is shaped by specially designed triangular and trapezoidal masks. To obtain correctly dimensioned and smooth grating surfaces, different materials (SU-8, polycarbonate, Epoclad and Epocore) are subjected to the laser ablation with optimized laser processing parameters. The resulting grating structures on Epocore exhibit the best surface roughness and dimensional fidelity. Optionally, spacers for maintaining the cell gap of the superimposed liquid crystal layer can also be fabricated in the same process. Two different methods were demonstrated: overlapping ablation and double mask ablation. Micro-grating structures were produced that deflect a monochromatic (543 nm) laser beam to the theoretically predicted 11th order with an angle of 7°.

  11. Multilevel diffractive optical element manufacture by excimer laser ablation and halftone masks

    NASA Astrophysics Data System (ADS)

    Quentel, Francois; Fieret, Jim; Holmes, Andrew S.; Paineau, Sylvain

    2001-06-01

    A novel method is presented to manufacture multilevel diffractive optical elements (DOEs) in polymer by single- step KrF excimer laser ablation using a halftone mask. The DOEs have a typical pixel dimension of 5 micrometers and are up to 512 by 512 pixels in size. The DOEs presented are Fresnel lenses and Fourier computer generated holograms, calculated by means of a conventional iterative Fourier transform algorithm. The halftone mask is built up as an array of 5 micrometers -square pixels, each containing a rectangular or L- shaped window on an opaque background. The mask is imaged onto the polymer with a 5x, 0.13 NA reduction lens. The pixels are not resolved by the lens, so they behave simply as attenuators, allowing spatial variation of the ablation rate via the window size. The advantages of halftone mask technology over other methods, such as pixel-by-pixel ablation and multi-mask overlay, are that it is very fast regardless of DOE size, and that no high-precision motion stages and alignment are required. The challenges are that the halftone mask is specific to the etch curve of the polymer used, that precise calibration of each grey-level is required, and that the halftone mask must be calculated specifically for the imaging lens used. This paper describes the design procedures for multilevel DOEs and halftone masks, the calibration of the various levels, and some preliminary DOE test results.

  12. Femtosecond laser ablation of CuxZr1-x bulk metallic glasses: A molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Marinier, Sébastien; Lewis, Laurent J.

    2015-11-01

    Molecular-dynamics simulations combined with a two-temperature model are used to study laser ablation in CuxZr1-x (x =0.33 ,0.50 ,0.67 ) metallic glasses as well as crystalline CuZr2 in the C11b (MoSi2) structure. Ablation thresholds are found to be 430 ±10 ,450 ±10 ,510 ±10 , and 470 ±10 J/m 2 for a-Cu2Zr , a-CuZr, a-CuZr2, and c-CuZr2, respectively. The larger threshold in amorphous CuZr2 results from a weaker electron-phonon coupling and thus longer electron-ion equilibration time. We observe that the velocity of the pressure waves in the amorphous samples is not affected by the fluence, in contrast to the crystal; this is due to differences in the behavior of the shear modulus with increasing pressure. The heat-affected zone in the different systems is characterized in terms of the melting depth as well as inelastic deformations. The melting depth is found to be smaller in the crystal than in the amorphous targets because of its higher melting temperature. The inelastic deformations are investigated in terms of the von Mises shear strain invariant ηMises; the homogeneous nucleation of shear transformation zones is observed in the glass as reported in previous theoretical and experimental studies. The coalescence of the shear transformation zones is also found at higher fluence.

  13. Timbre Dimensions for Musical Control

    NASA Astrophysics Data System (ADS)

    Giese, Gregory Roy

    This dissertation addresses the folowing question: Given the technologies to develop and implement any kind of sound generating and controlling device, what will the instrument designer, the composer, and the performer need to know in order to more fully utilize the dimensions of timbre in music and musical performance? This question is approached from the standpoint of music theory. Definitions of timbre and a few examples of related physical and perceptual research are reviewed. Included is a discussion of the essential elements of musical control and of intelligent organization of sound in music. This discussion raises more questions than can be answered simply. It is an attempt to unravel the nature of sound clues and sound qualities as they convey sound identities and musical gesture. A theoretical simplification of sound dimensions for musical use is proposed. Sounds which can be sustained indefinitely consist of steady-state acoustical dimensions. These dimensions rely upon the perceptual phenomenon of simultaneous fusion (synance). Sounds which can not be sustained indefinitely consist of transitions. Transitions may cause successive fusion (sonance). The discussion of steady-state and transition dimensions includes a review of a few informal experiments. This work reveals problems that will influence the musical use of timbre dimensions. It also leads to a theory for the organization and control of timbre dimensions in music. Among the timbre dimensions discussed are: spectral envelope, harmonic content, brightness, phase, inharmonicity, aperiodicity, and temporal transitions. Questions are raised regarding the perception of harmonic content. The effect of register on perception of tones consisting of from two to nine partials is explored and discussed. The size of interval between partials determines a unique quality. This is most apparent with tones consisting of only two or three partials (dions or trions).

  14. Increasing the dimensions of metrology

    NASA Astrophysics Data System (ADS)

    Maurer, Wilhelm; Blaesing-Bangert, Carola; Paul, Hans-Helmut

    1990-06-01

    In any process that generates or measures pattern-placement (overlay), these parameters need to be regarded at least as two-dimensional. We show this on our procedure bringing a mask repeater under statistical process control SPC). In order to increase the accuracy of the overlay measurement process itself, plate bending has to be included as a third dimension. By taking the third dimension into account, the LMS 2000 Metrology System significantly reduces the maximum uncertainity of measurement results.

  15. Superselective Particle Embolization Enhances Efficacy of Radiofrequency Ablation: Effects of Particle Size and Sequence of Action

    SciTech Connect

    Tanaka, Toshihiro; Isfort, Peter; Braunschweig, Till Westphal, Saskia; Woitok, Anna; Penzkofer, Tobias Bruners, Philipp; Kichikawa, Kimihiko; Schmitz-Rode, Thomas Mahnken, Andreas H.

    2013-06-15

    Purpose. To evaluate the effects of particle size and course of action of superselective bland transcatheter arterial embolization (TAE) on the efficacy of radiofrequency ablation (RFA). Methods. Twenty pigs were divided into five groups: group 1a, 40-{mu}m bland TAE before RFA; group 1b, 40-{mu}m bland TAE after RFA; group 2a, 250-{mu}m bland TAE before RFA; group 2b, 250-{mu}m bland TAE after RFA and group 3, RFA alone. A total of 40 treatments were performed with a combined CT and angiography system. The sizes of the treated zones were measured from contrast-enhanced CTs on days 1 and 28. Animals were humanely killed, and the treated zones were examined pathologically. Results. There were no complications during procedures and follow-up. The short-axis diameter of the ablation zone in group 1a (mean {+-} standard deviation, 3.19 {+-} 0.39 cm) was significantly larger than in group 1b (2.44 {+-} 0.52 cm; P = 0.021), group 2a (2.51 {+-} 0.32 cm; P = 0.048), group 2b (2.19 {+-} 0.44 cm; P = 0.02), and group 3 (1.91 {+-} 0.55 cm; P < 0.001). The greatest volume of ablation was achieved by performing embolization with 40-{mu}m particles before RFA (group 1a; 20.97 {+-} 9.65 cm{sup 3}). At histology, 40-{mu}m microspheres were observed to occlude smaller and more distal arteries than 250-{mu}m microspheres. Conclusion. Bland TAE is more effective before RFA than postablation embolization. The use of very small 40-{mu}m microspheres enhances the efficacy of RFA more than the use of larger particles.

  16. Radiative ablation of disks around massive stars

    NASA Astrophysics Data System (ADS)

    Kee, Nathaniel Dylan

    Hot, massive stars (spectral types O and B) have extreme luminosities (10. 4 -10. 6 L?) that drive strong stellar winds through UV line-scattering.Some massive stars also have disks, formed by either decretion from the star (as in the rapidly rotating "Classical Be stars"), or accretion during the star's formation. This dissertation examines the role of stellar radiation in driving (ablating) material away from these circumstellar disks. A key result is that the observed month to year decay of Classical Be disks can be explained by line-driven ablation without, as previously done, appealing to anomalously strong viscous diffusion. Moreover, the higher luminosity of O stars leads to ablation of optically thin disks on dynamical timescales of order a day, providing a natural explanation for the lack of observed Oe stars. In addition to the destruction of Be disks, this dissertation also introduces a model for their formation by coupling observationally inferred non-radial pulsation modes and rapid stellar rotation to launch material into orbiting Keplerian disks of Be-like densities. In contrast to such Be decretion disks, star-forming accretion disks are much denser and so are generally optically thick to continuum processes. To circumvent the computational challenges associated with radiation hydrodynamics through optically thick media, we develop an approximate method for treating continuum absorption in the limit of geometrically thin disks. The comparison of ablation with and without continuum absorption shows that accounting for disk optical thickness leads to less than a 50% reduction in ablation rate, implying that ablation rate depends mainly on stellar properties like luminosity. Finally, we discuss the role of "thin-shell mixing" in reducing X-rays from colliding wind binaries. Laminar, adiabatic shocks produce well understood X-ray emission, but the emission from radiatively cooled shocks is more complex due to thin-shell instabilities. The parameter

  17. Temperature profiles of 980- and 1,470-nm endovenous laser ablation, endovenous radiofrequency ablation and endovenous steam ablation.

    PubMed

    Malskat, W S J; Stokbroekx, M A L; van der Geld, C W M; Nijsten, T E C; van den Bos, R R

    2014-03-01

    Endovenous thermal ablation (EVTA) techniques are very effective for the treatment of varicose veins, but their exact working mechanism is still not well documented. The lack of knowledge of mechanistic properties has led to a variety of EVTA protocols and a commercially driven dissemination of new or modified techniques without robust scientific evidence. The aim of this study is to compare temperature profiles of 980-and 1,470-nm endovenous laser ablation (EVLA), segmental radiofrequency ablation (RFA), and endovenous steam ablation (EVSA). In an experimental setting, temperature measurements were performed using thermocouples; raw potato was used to mimic a vein wall. Two laser wavelengths (980 and 1,470 nm) were used with tulip-tip fibers and 1,470 nm also with a radial-emitting fiber. Different powers and pullback speeds were used to achieve fluences of 30, 60, and 90 J/cm. For segmental RFA, 1 cycle of 20 s was analyzed. EVSA was performed with two and three pulses of steam per centimeter. Maximum temperature increase, time span of relevant temperature increase, and area under the curve of the time of relevant temperature increase were measured. In all EVLA settings, temperatures increased and decreased rapidly. High fluence is associated with significantly higher temperatures and increased time span of temperature rise. Temperature profiles of 980- and 1,470-nm EVLA with tulip-tip fibers did not differ significantly. Radial EVLA showed significantly higher maximum temperatures than tulip-tip EVLA. EVSA resulted in mild peak temperatures for longer durations than EVLA. Maximum temperatures with three pulses per centimeter were significantly higher than with two pulses. RFA temperature rises were relatively mild, resulting in a plateau-shaped temperature profile, similar to EVSA. Temperature increase during EVLA is fast with a high-peak temperature for a short time, where EVSA and RFA have longer plateau phases and lower maximum temperatures. PMID

  18. Formation of the surface structure of polyethylene-terephtalate (PET) due to ArF excimer laser ablation

    NASA Astrophysics Data System (ADS)

    Hopp, B.; Csete, M.; Révész, K.; Vinkó, J.; Bor, Zs.

    1996-04-01

    The development process of the surface structure on polyethylene-terephtalate (PET) has been investigated. It was found that the average dimension and shape of its unit cells depend on the excimer laser fluence, the incident angle of the ablating laser beam (the longitudinal dimension is proportional to cons × tan( α) + D formula, where D means the average dimension of the unit cell at α = 0°) and the number of shots (the average dimension and height proportional to the logarithm of the number of shots). A dye laser based arrangement was constructed to investigate the temporal dependence of the scattered probe light intensity from the ablated polymer surface. It was found that the formation of the surface structure takes place in the time range of 5-10 μs. We used a heat diffusion melting model to explain the development of the surface structure. A simple 1D simulation of the heat transfer shows that the lifetime of the liquid phase (˜ 1-7 μs) is comparable with the time scale mentioned above.

  19. Atrial conduction delay predicts atrial fibrillation in paroxysmal supraventricular tachycardia patients after radiofrequency catheter ablation.

    PubMed

    Xu, Zhen-Xing; Zhong, Jing-Quan; Zhang, Wei; Yue, Xin; Rong, Bing; Zhu, Qing; Zheng, Zhaotong; Zhang, Yun

    2014-06-01

    This study aimed to assess whether intra- and inter-atrial conduction delay could predict atrial fibrillation (AF) for paroxysmal supraventricular tachycardia (PSVT) patients after successful treatment by radiofrequency catheter ablation (RFCA). Echocardiography examination was performed on 524 consecutive PSVT patients (15 patients were excluded). Left atrial dimension, right atrial diameter and intra- and inter-atrial conduction delay were measured before ablation. Patients were divided into group A (n = 32): occurrence of AF after the ablation and group B (n = 477): remained in sinus rhythm during follow-up. Receiver operating characteristic (ROC) curve analysis was performed to estimate the predictive value of intra- and inter-atrial conduction delay. Both intra- and inter-atrial conduction delay were higher in group A than in group B (4.79 ± 0.30 msec vs. 4.56 ± 0.32 msec; 21.98 ± 1.32 msec vs. 20.01 ± 1.33; p < 0.05). Binary logistic regression analysis showed that intra- and inter-atrial conduction were significant influential factors for the occurrence of AF (odds ratio [OR] = 13.577, 95% confidence interval [CI], 3.469-48.914; OR = 2.569, 95% CI, 1.909-3.459, p < 0.05). The ROC cure analysis revealed that intra-atrial conduction delay ≥ 4.45 msec and inter-atrial conduction delay ≥ 20.65 were the most optimal cut-off value for predicting AF in PSVT patients after RFCA. In conclusion, this is the first study to show that the intra- and inter-atrial conduction delay could effectively predict AF in post-ablation PSVT patients.

  20. The absorption and radiation of a tungsten plasma plume during nanosecond laser ablation

    SciTech Connect

    Moscicki, T. Hoffman, J.; Chrzanowska, J.

    2015-10-15

    In this paper, the effect of absorption of the laser beam and subsequent radiation on the dynamics of a tungsten plasma plume during pulsed laser ablation is analyzed. Different laser wavelengths are taken into consideration. The absorption and emission coefficients of tungsten plasma in a pressure range of 0.1–100 MPa and temperature up to 70 000 K are presented. The shielding effects due to the absorption and radiation of plasma may have an impact on the course of ablation. The numerical model that describes the tungsten target heating and the formation of the plasma and its expansion were made for 355 nm and 1064 nm wavelengths of a Nd:YAG laser. The laser beam with a Gaussian profile was focused to a spot size of 0.055 mm{sup 2} with a power density of 1 × 10{sup 9 }W/cm{sup 2} (10 ns full width half maximum pulse duration). The plasma expands into air at ambient pressure of 1 mPa. The use of the shorter wavelength causes faster heating of the target, thus the higher ablation rate. The consequences of a higher ablation rate are slower expansion and smaller dimensions of the plasma plume. The higher plasma temperature in the case of 1064 nm is due to the lower density and lower plasma radiation. In the initial phase of propagation of the plasma plume, when both the temperature and pressure are very high, the dominant radiation is emission due to photo-recombination. However, for a 1064 nm laser wavelength after 100 ns of plasma expansion, the radiation of the spectral lines is up to 46.5% of the total plasma radiation and should not be neglected.

  1. Generation of Ag-di water nanofluids using multipulse laser ablation in liquid approach

    SciTech Connect

    Tran, P X; Soong, Yee; Gupta, R K; Walker, L M; White, L R; Kuntz, D M

    2007-09-01

    Multiple laser ablation of a silver sample submerged in deionized water was carried out. The generated nanofluids were characterized using a variety of techniques to determine particle size, stability and surface properties. Results of transmission electron microscopy (TEM) and dynamic light scattering (DLS) indicate that the nanoparticles are reasonably monodisperse with sizes ranging from 10 – 60 nm depending on details of the ablation method. For the single pulse approach, the majority of the particles were in 14 – 32 nm range. There were some big ones as large as 50 – 60 nm in size. For double pulse approach, the particle sizes were more uniform and the majority of the particles were in 9 – 21 nm range with some big ones ranging from 23 – 26 nm in size. For stability analysis, one of the samples was filtered using a 0.45 μm filter and then re-analyzed. The result was essentially identical to those obtained when non-filtered samples were used. To test the possibility of particle aggregation, the sample was sonicated using an ultrasonic probe and then analyzed. These results again were identical to the other runs of the non-sonicated and non-filtered samples. All UV-VIS spectra on silver particles showed a surface plasmon peak around 409 nm and the absorbance versus concentration relationship was indeed linear over a range of dilutions of the stock solutions. Using Beer’s law and the slope of the curve showing the absorbance versus concentration data, concentrations of several stock solutions were measured to determine the impact of laser ablation variables on suspension concentration. It appears that the multiple laser ablation technique produces silver-based nanofluids of stability and controllable particle dimensions and laser configuration may dictate product concentration as well as product characteristic size.

  2. Role of wavelength and pulse duration in laser ablation: implications to beam delivery, surface modifications, and diagnostic techniques

    NASA Astrophysics Data System (ADS)

    Serafetinides, Alexander A.

    1999-05-01

    The basic interaction mechanism of pulsed laser ablation of tissue reveals a complexity of parameters, such as the optical properties of the tissue and the technical characteristics of the laser beam. The role of the laser wavelength, the pulse duration, the energy fluence, etc. as well as the implications on the beam delivery means, the ablated surface modifications and the diagnostic techniques employed are under investigation. For example, it was experimentally verified that when using mid-infrared lasers with pulse durations in the ns range, the photothermal mechanism involved exhibits strong absorption restricting the residual thermal damage to a relatively small zone. On the other hand the ablation of tissue with ultrashort, picosecond and femtosecond, visible and near-infrared laser pulses has been investigated as an alternative, as the energy threshold for ablation biological tissue, depends approximately on the square root of the pulse duration. However the pulse length shortening creates problems to the fibers or the waveguides ends, due to the very high laser power densities involved. Conventional and advanced microscopy, scanning electron microscopy--SEM and atomic force microscopy--AFM, were used to study the surface and ends alterations of the delivery system involved and the surface alterations of the soft or the hard tissue target in pulsed laser ablation. Finally differentiation between the normal and the pathological tissue was achieved by employing the laser induced fluorescence--LIF diagnostic technique in a long term effort to develop a computer aided system, which will facilitate the automated, real-time characterization of healthy or atherosclerotic plaques in a less invasive laser ablation clinical procedure.

  3. Interstitial ultrasound ablation of tumors within or adjacent to bone: Contributions of preferential heating at the bone surface

    NASA Astrophysics Data System (ADS)

    Scott, Serena J.; Prakash, Punit; Salgaonkar, Vasant; Jones, Peter D.; Cam, Richard N.; Han, Misung; Rieke, Viola; Burdette, E. Clif; Diederich, Chris J.

    2013-02-01

    Preferential heating of bone due to high ultrasound attenuation may enhance thermal ablation performed with cathetercooled interstitial ultrasound applicators in or near bone. At the same time, thermally and acoustically insulating cortical bone may protect sensitive structures nearby. 3D acoustic and biothermal transient finite element models were developed to simulate temperature and thermal dose distributions during catheter-cooled interstitial ultrasound ablation near bone. Experiments in ex vivo tissues and tissue-mimicking phantoms were performed to validate the models and to quantify the temperature profiles and ablated volumes for various distances between the interstitial applicator and the bone surface. 3D patient-specific models selected to bracket the range of clinical usage were developed to investigate what types of tumors could be treated, applicator configurations, insertion paths, safety margins, and other parameters. Experiments show that preferential heating at the bone surface decreases treatment times compared to when bone is absent and that all tissue between an applicator and bone can be ablated when they are up to 2 cm apart. Simulations indicate that a 5-7 mm safety margin of normal bone is needed to protect (thermal dose < 6 CEM43°C and T < 45°C) sensitive structures behind ablated bone. In 3D patient-specific simulations, tumors 1.0-3.8 cm (L) and 1.3-3.0 cm (D) near or within bone were ablated (thermal dose > 240 CEM43°C) within 10 min without damaging the nearby spinal cord, lungs, esophagus, trachea, or major vasculature. Preferential absorption of ultrasound by bone may provide improved localization, faster treatment times, and larger treatment zones in tumors in and near bone compared to other heating modalities.

  4. Pathology of non-thermal irreversible electroporation (N-TIRE)-induced ablation of the canine brain.

    PubMed

    Rossmeisl, John H; Garcia, Paulo A; Roberston, John L; Ellis, Thomas L; Davalos, Rafael V

    2013-01-01

    This study describes the neuropathologic features of normal canine brain ablated with non-thermal irreversible electroporation (N-TIRE). The parietal cerebral cortices of four dogs were treated with N-TIRE using a dose-escalation protocol with an additional dog receiving sham treatment. Animals were allowed to recover following N-TIRE ablation and the effects of treatment were monitored with clinical and magnetic resonance imaging examinations. Brains were subjected to histopathologic and ultrastructural assessment along with Bcl-2, caspase-3, and caspase-9 immunohistochemical staining following sacrifice 72 h post-treatment. Adverse clinical effects of N-TIRE were only observed in the dog treated at the upper energy tier. MRI and neuropathologic examinations indicated that N-TIRE ablation resulted in focal regions of severe cytoarchitectural and blood-brain-barrier disruption. Lesion size correlated to the intensity of the applied electrical field. N-TIRE-induced lesions were characterized by parenchymal necrosis and hemorrhage; however, large blood vessels were preserved. A transition zone containing parenchymal edema, perivascular inflammatory cuffs, and reactive gliosis was interspersed between the necrotic focus and normal neuropil. Apoptotic labeling indices were not different between the N-TIRE-treated and control brains. This study identified N-TIRE pulse parameters that can be used to safely create circumscribed foci of brain necrosis while selectively preserving major vascular structures. PMID:23820168

  5. Pathology of non-thermal irreversible electroporation (N-TIRE)-induced ablation of the canine brain

    PubMed Central

    Garcia, Paulo A.; Roberston, John L.; Ellis, Thomas L.; Davalos, Rafael V.

    2013-01-01

    This study describes the neuropathologic features of normal canine brain ablated with non-thermal irreversible electroporation (N-TIRE). The parietal cerebral cortices of four dogs were treated with N-TIRE using a dose-escalation protocol with an additional dog receiving sham treatment. Animals were allowed to recover following N-TIRE ablation and the effects of treatment were monitored with clinical and magnetic resonance imaging examinations. Brains were subjected to histopathologic and ultrastructural assessment along with Bcl-2, caspase-3, and caspase-9 immunohistochemical staining following sacrifice 72 h post-treatment. Adverse clinical effects of N-TIRE were only observed in the dog treated at the upper energy tier. MRI and neuropathologic examinations indicated that N-TIRE ablation resulted in focal regions of severe cytoarchitectural and blood-brain-barrier disruption. Lesion size correlated to the intensity of the applied electrical field. N-TIRE-induced lesions were characterized by parenchymal necrosis and hemorrhage; however, large blood vessels were preserved. A transition zone containing parenchymal edema, perivascular inflammatory cuffs, and reactive gliosis was interspersed between the necrotic focus and normal neuropil. Apoptotic labeling indices were not different between the N-TIRE-treated and control brains. This study identified N-TIRE pulse parameters that can be used to safely create circumscribed foci of brain necrosis while selectively preserving major vascular structures. PMID:23820168

  6. Microwave-activated nanodroplet vaporization for highly efficient tumor ablation with real-time monitoring performance.

    PubMed

    Xu, Jinshun; Chen, Yu; Deng, Liming; Liu, Jianxin; Cao, Yang; Li, Pan; Ran, Haitao; Zheng, Yuanyi; Wang, Zhigang

    2016-11-01

    The fast development of nanotechnology has provided a new efficient strategy for enhancing the therapeutic efficiency of various treatment modalities against cancer. However, the improvement of minimally invasive microwave therapy based on nanomaterials has not been realized. In this work, we successfully designed and synthesized a novel folate-targeted nanodroplet (TPN) with a composite mixture of perfluorocarbons as the core and lipid as the shell, which exerts the distinctive dual functions as the adjuvant for highly efficient percutaneous ultrasound imaging-guided microwave ablation (MWA) of tumors. Based on the unique phase-changeable performance of TPN nanosystem, a novel microwave-droplet vaporization (MWDV) strategy was proposed, for the first time, to overcome the critical issues of traditional acoustic-droplet vaporization (ADV) and optical-droplet vaporization (ODV) for cancer theranostics. Especially, the elaborately designed TPN can overcome the challenges of indistinct imaging of ablation margin and the limited ablation zone of MWA modality against cancer. The high efficiency of this new MWDV strategy has been systematically elucidated in vitro, ex vivo and in vivo. Therefore, such a successful demonstration of the role of nanomaterials (TPN in this case) in ultrasound imaging-guided MWA therapy against cancer provides a highly feasible strategy to effectively enhance the MWA outcome with the specific features of high efficiency and biosafety. PMID:27573134

  7. Fractal dimension of alumina aggregates grown in two dimensions

    NASA Technical Reports Server (NTRS)

    Larosa, Judith L.; Cawley, James D.

    1992-01-01

    The concepts of fractal geometry are applied to the analysis of 0.4-micron alumina constrained to agglomerate in two dimensions. Particles were trapped at the bottom surface of a drop of a dilute suspension, and the agglomeration process was directly observed, using an inverted optical microscope. Photographs were digitized and analyzed, using three distinct approaches. The results indicate that the agglomerates are fractal, having a dimension of approximately 1.5, which agrees well with the predictions of the diffusion-limited cluster-cluster aggregation model.

  8. Automated planning of ablation targets in atrial fibrillation treatment

    NASA Astrophysics Data System (ADS)

    Keustermans, Johannes; De Buck, Stijn; Heidbüchel, Hein; Suetens, Paul

    2011-03-01

    Catheter based radio-frequency ablation is used as an invasive treatment of atrial fibrillation. This procedure is often guided by the use of 3D anatomical models obtained from CT, MRI or rotational angiography. During the intervention the operator accurately guides the catheter to prespecified target ablation lines. The planning stage, however, can be time consuming and operator dependent which is suboptimal both from a cost and health perspective. Therefore, we present a novel statistical model-based algorithm for locating ablation targets from 3D rotational angiography images. Based on a training data set of 20 patients, consisting of 3D rotational angiography images with 30 manually indicated ablation points, a statistical local appearance and shape model is built. The local appearance model is based on local image descriptors to capture the intensity patterns around each ablation point. The local shape model is constructed by embedding the ablation points in an undirected graph and imposing that each ablation point only interacts with its neighbors. Identifying the ablation points on a new 3D rotational angiography image is performed by proposing a set of possible candidate locations for each ablation point, as such, converting the problem into a labeling problem. The algorithm is validated using a leave-one-out-approach on the training data set, by computing the distance between the ablation lines obtained by the algorithm and the manually identified ablation points. The distance error is equal to 3.8+/-2.9 mm. As ablation lesion size is around 5-7 mm, automated planning of ablation targets by the presented approach is sufficiently accurate.

  9. Dimension of fractal basin boundaries

    SciTech Connect

    Park, B.S.

    1988-01-01

    In many dynamical systems, multiple attractors coexist for certain parameter ranges. The set of initial conditions that asymptotically approach each attractor is its basin of attraction. These basins can be intertwined on arbitrary small scales. Basin boundary can be either smooth or fractal. Dynamical systems that have fractal basin boundary show final state sensitivity of the initial conditions. A measure of this sensitivity (uncertainty exponent {alpha}) is related to the dimension of the basin boundary d = D - {alpha}, where D is the dimension of the phase space and d is the dimension of the basin boundary. At metamorphosis values of the parameter, there might happen a conversion from smooth to fractal basin boundary (smooth-fractal metamorphosis) or a conversion from fractal to another fractal basin boundary characteristically different from the previous fractal one (fractal-fractal metamorphosis). The dimension changes continuously with the parameter except at the metamorphosis values where the dimension of the basin boundary jumps discontinuously. We chose the Henon map and the forced damped pendulum to investigate this. Scaling of the basin volumes near the metamorphosis values of the parameter is also being studied for the Henon map. Observations are explained analytically by using low dimensional model map.

  10. Root apex transition zone as oscillatory zone.

    PubMed

    Baluška, František; Mancuso, Stefano

    2013-01-01

    Root apex of higher plants shows very high sensitivity to environmental stimuli. The root cap acts as the most prominent plant sensory organ; sensing diverse physical parameters such as gravity, light, humidity, oxygen, and critical inorganic nutrients. However, the motoric responses to these stimuli are accomplished in the elongation region. This spatial discrepancy was solved when we have discovered and characterized the transition zone which is interpolated between the apical meristem and the subapical elongation zone. Cells of this zone are very active in the cytoskeletal rearrangements, endocytosis and endocytic vesicle recycling, as well as in electric activities. Here we discuss the oscillatory nature of the transition zone which, together with several other features of this zone, suggest that it acts as some kind of command center. In accordance with the early proposal of Charles and Francis Darwin, cells of this root zone receive sensory information from the root cap and instruct the motoric responses of cells in the elongation zone.

  11. Root Apex Transition Zone As Oscillatory Zone

    PubMed Central

    Baluška, František; Mancuso, Stefano

    2013-01-01

    Root apex of higher plants shows very high sensitivity to environmental stimuli. The root cap acts as the most prominent plant sensory organ; sensing diverse physical parameters such as gravity, light, humidity, oxygen, and critical inorganic nutrients. However, the motoric responses to these stimuli are accomplished in the elongation region. This spatial discrepancy was solved when we have discovered and characterized the transition zone which is interpolated between the apical meristem and the subapical elongation zone. Cells of this zone are very active in the cytoskeletal rearrangements, endocytosis and endocytic vesicle recycling, as well as in electric activities. Here we discuss the oscillatory nature of the transition zone which, together with several other features of this zone, suggest that it acts as some kind of command center. In accordance with the early proposal of Charles and Francis Darwin, cells of this root zone receive sensory information from the root cap and instruct the motoric responses of cells in the elongation zone. PMID:24106493

  12. Particle analysis using laser ablation mass spectroscopy

    DOEpatents

    Parker, Eric P.; Rosenthal, Stephen E.; Trahan, Michael W.; Wagner, John S.

    2003-09-09

    The present invention provides a method of quickly identifying bioaerosols by class, even if the subject bioaerosol has not been previously encountered. The method begins by collecting laser ablation mass spectra from known particles. The spectra are correlated with the known particles, including the species of particle and the classification (e.g., bacteria). The spectra can then be used to train a neural network, for example using genetic algorithm-based training, to recognize each spectra and to recognize characteristics of the classifications. The spectra can also be used in a multivariate patch algorithm. Laser ablation mass specta from unknown particles can be presented as inputs to the trained neural net for identification as to classification. The description below first describes suitable intelligent algorithms and multivariate patch algorithms, then presents an example of the present invention including results.

  13. Ablative Therapies for Colorectal Polyps and Malignancy

    PubMed Central

    Hochwald, Steven N.; Nurkin, Steven

    2014-01-01

    Endoscopic techniques are gaining popularity in the management of colorectal polyps and occasionally superficial cancers. While their use is in many times palliative, they have proven to be curative in carefully selected patients with polyps or malignancies, with less morbidity than radical resection. However, one should note that data supporting local and ablative therapies for colorectal cancer is scarce and may be subject to publication bias. Therefore, for curative intent, these techniques should only be considered in highly select cases as higher rates of local recurrences have also been reported. The aim of this review is to explain the different modalities of local and ablative therapies specific to colorectal neoplasia and explain the indications and circumstances where they have been most successful. PMID:25089281

  14. Thrust improvement with ablative insert nozzle extension

    NASA Technical Reports Server (NTRS)

    Clayton, R. M.; Back, L. H.

    1986-01-01

    Aspects are examined of an investigation by the Marshall Space Flight Center into the conceptual feasibility of increasing the thrust performance of the Space Shuttle Main Engine (SSME) by using a conical nozzle extension fitted with an ablative insert in order to achieve a low-cost, near-term gain in payload. The ablating insert would provide a controlled increase in nozzle expansion ratio during launch and early climbout (first 30-60 seconds) so as to reduce thrust loss from nozzle over-expansion in the lower atmosphere. Summaries are given of JPL studies in the area of: defining the near-wall flow environment in the extended nozzle insert region; selecting potential insert materials; conceptualizing an extension/insert geometrical configuration; and identifying future experimental efforts necessary to verify the feasibility of the concepts.

  15. Glycine Ablation during Comet/Meteoroid Impact

    NASA Technical Reports Server (NTRS)

    Huo, Winifred M.; Dateo, Christopher E.; Mckay, Christopher P.; Borucki, William J.

    2004-01-01

    Amino acids and other organic compounds important to the chemistry of life are thought to have been delivered to early Earth by asteroids and comets. The survivability of such compounds upon high speed entry is not well understood. If molecular processing occurs during entry, the nature of the new molecules produced by such processing is also an open question. To address this question, we have initiated a study of the ablation of glycine, the simplest amino acid, upon the high speed entry of a comet or meteoroid into an atmosphere. The study assumes glycine is distributed on the surface of the comet/meteoroid. The high speed impact creates electrons, ions, and radicals in the atmosphere that react with the surface and either desorb glycine or break it up. The ablation process is studied as a function of entry speed and atmospheric composition. The AURORA code from the commercially available software package CHEMKIN is used in the study.

  16. Pulmonary radiofrequency ablation (Part 1): current state.

    PubMed

    Plasencia Martínez, J M

    2015-01-01

    The risks involved in surgical treatment and conventional radiotherapy in patients with early lung cancer or lung metastases often make these treatments difficult to justify. However, on the other hand, it is also unacceptable to allow these lesions to evolve freely because, left untreated, these neoplasms will usually lead to the death of the patient. In recent years, alternative local therapies have been developed, such as pulmonary radiofrequency ablation, which has proven to increase survival with a minimal risk of complications. There are common recommendations for these treatments, and although the specific indications for using one technique or another have yet to be established, there are clearly defined situations that will determine the outcome of the treatment. It is important to know these situations, because appropriate patient selection is essential for therapeutic success. This article aims to describe the characteristics and constraints of pulmonary radiofrequency ablation and to outline its role in thoracic oncology in light of the current evidence. PMID:25766072

  17. Palliative Radiofrequency Ablation for Recurrent Prostate Cancer

    SciTech Connect

    Jindal, Gaurav; Friedman, Marc; Locklin, Julia Wood, Bradford J.

    2006-06-15

    Percutaneous radiofrequency ablation (RFA) is a minimally invasive local therapy for cancer. Its efficacy is now becoming well documented in many different organs, including liver, kidney, and lung. The goal of RFA is typically complete eradication of a tumor in lieu of an invasive surgical procedure. However, RFA can also play an important role in the palliative care of cancer patients. Tumors which are surgically unresectable and incompatible for complete ablation present the opportunity for RFA to be used in a new paradigm. Cancer pain runs the gamut from minor discomfort relieved with mild pain medication to unrelenting suffering for the patient, poorly controlled by conventional means. RFA is a tool which can potentially palliate intractable cancer pain. We present here a case in which RFA provided pain relief in a patient with metastatic prostate cancer with pain uncontrolled by conventional methods.

  18. Occipital lobe infarction following cardiac ablation.

    PubMed

    Mirza, Rukhsana G; Biller, Jose; Jay, Walter M

    2004-01-01

    A 60-year-old man presented with the chief complaint of seeing a blurred area just up and to the left of the center of his vision. The patient noted this visual field defect immediately after he awoke from a cardiac electrophysiologic study with a catheter ablation procedure. On neuro-ophthalmologic testing, a small scotoma was present superior and left of fixation in both eyes. MRI showed a small irregular area of abnormal signal in the right occipital lobe consistent with an ischemic lesion. To the best of our knowledge, this represents the first case report of a homonymous visual field defect secondary to an occipital lobe infarction following a cardiac catheter ablation procedure.

  19. Laser ablation of gall bladder stones

    NASA Astrophysics Data System (ADS)

    Marafi, M.; Makdisi, Y.; Bhatia, K. S.; Abdulah, A. H.; Kokaj, Y.; Mathew, K.; Quinn, F.; Qabazard, A.

    1999-06-01

    Study of laser interaction with calculi is presented. A system of Nd-Yag and Ho-Yag pulsed lasers were used to produce fluorescence and plasma signals at the stone surface surrounded by saline and bile fluids. Fourth harmonic from Nd-Yag laser was transmitted to the samples by graded UV optical fibres. Gall bladder stones of various compositions were subjected to the high power Ho-Yag laser. Temporal transients and spectral evolution of plasma and fluorescence signals were monitored by a streak camera. A profile of acoustic pressures generated by shock waves was recorded with sensitive hydrophones placed in the surrounding fluids. Ablation threshold, cavitation process and fluorescence dependence on the laser parameters were studied in detail. Potential of stone identification by fluorescence and possible hydrodynamic model for ablation of biological samples is discussed.

  20. Simulation of ablation in Earth atmospheric entry

    NASA Technical Reports Server (NTRS)

    Keenan, James A.; Candler, Graham V.

    1993-01-01

    The process of ablation for Earth atmospheric entry is simulated using a computational approach that allows thermo-chemical nonequilibrium of the flow field and ablation gases. The heat pulse into the heat shield is modeled. The flowfield and graphite heat shield are coupled through surface mass and energy balances. The surface thermochemistry involves the oxidation of graphite and allows for catalytic recombination of diatomic oxygen. Steady-state simulations are performed on a one meter nose radius sphere at an altitude of 65/km and at freestream velocities of 8 km/s and 10 km/s. A transient simulation is performed at 65 km altitude and a freestream velocity of 10 km/s.

  1. Pulmonary radiofrequency ablation (Part 1): current state.

    PubMed

    Plasencia Martínez, J M

    2015-01-01

    The risks involved in surgical treatment and conventional radiotherapy in patients with early lung cancer or lung metastases often make these treatments difficult to justify. However, on the other hand, it is also unacceptable to allow these lesions to evolve freely because, left untreated, these neoplasms will usually lead to the death of the patient. In recent years, alternative local therapies have been developed, such as pulmonary radiofrequency ablation, which has proven to increase survival with a minimal risk of complications. There are common recommendations for these treatments, and although the specific indications for using one technique or another have yet to be established, there are clearly defined situations that will determine the outcome of the treatment. It is important to know these situations, because appropriate patient selection is essential for therapeutic success. This article aims to describe the characteristics and constraints of pulmonary radiofrequency ablation and to outline its role in thoracic oncology in light of the current evidence.

  2. 3D Multifunctional Ablative Thermal Protection System

    NASA Technical Reports Server (NTRS)

    Feldman, Jay; Venkatapathy, Ethiraj; Wilkinson, Curt; Mercer, Ken

    2015-01-01

    NASA is developing the Orion spacecraft to carry astronauts farther into the solar system than ever before, with human exploration of Mars as its ultimate goal. One of the technologies required to enable this advanced, Apollo-shaped capsule is a 3-dimensional quartz fiber composite for the vehicle's compression pad. During its mission, the compression pad serves first as a structural component and later as an ablative heat shield, partially consumed on Earth re-entry. This presentation will summarize the development of a new 3D quartz cyanate ester composite material, 3-Dimensional Multifunctional Ablative Thermal Protection System (3D-MAT), designed to meet the mission requirements for the Orion compression pad. Manufacturing development, aerothermal (arc-jet) testing, structural performance, and the overall status of material development for the 2018 EM-1 flight test will be discussed.

  3. [Radiofrequency ablation of an unresectable abdominal tumor].

    PubMed

    Sézeur, Alain; Fritsch, Sylvie; Louvet, Christophe; Kujas, Albert; Mosnier, Henri; Talbot, Jean-Noël; Grimberg, Sylvie

    2003-02-01

    Remnant malignant tissue is left behind after conventional surgery for an unresectable intraperitoneal malignant tumor. Standard radiotherapy or chemotherapy rarely enables good tumor control. We report the case of a 74-year-old man who developed a local recurrence of a sigmoid tumor located 5 to 6 cm from the anus. The tumor was fixed to the pelvic wall and could not be totally eradicated with conventional surgery. Preoperative peroperative assessment confirmed the absence of metastatic spread. Radiotherapy could not be performed due to risk of bowel injury. Peroperative radiofrequency ablation was followed by surgical colorectal resection without restoration of intestinal continuity, leaving only tumor tissue destroyed by radiofrequency. No adjuvant treatment was proposed because of intolerance to chemotherapy. Clinical assessment and thoracic and abdominal CT scan confirmed the absence of recurrence 26 months after radiofrequency ablation. Serum markers remained normal.

  4. Tissue ablation technologies for localized prostate cancer.

    PubMed

    Gillett, Michael D; Gettman, Matthew T; Zincke, Horst; Blute, Michael L

    2004-12-01

    Traditional treatments for men with localized prostate cancer have included both surgical removal and radiation therapy, with their potential adverse effects on patient quality of life. Thus, there has been increasing interest in the development of minimally invasive procedures that use various technologies to deliver lethal doses of heat or cold to the prostate in an attempt to kill cancer cells. At the same time, it is vital that these newer techniques ablate prostate tissue and spare vital periprostatic organs essential for maintaining function and quality of life. In this article, we evaluate the current status of tissue ablation modalities in the treatment of clinically localized prostate cancer, focusing on the different methods, early results, and possible future directions. Although still in the beginning stages, these newer forms of treatment offer exciting potential for first-line and second-line treatment of this common urologic malignancy.

  5. Nozzle designs with pitch precursor ablatives

    NASA Technical Reports Server (NTRS)

    Blevins, H. R.; Bedard, R. J.

    1976-01-01

    Recent developments in carbon phenolic ablatives for solid rocket motor nozzles have yielded a pitch precursor carbon fiber offering significant raw material availability and cost saving advantages as compared to conventional rayon precursor material. This paper discusses the results of an experimental program conducted to assess the thermal performance and characterize the thermal properties of pitch precursor carbon phenolic ablatives. The end result of this program is the complete thermal characterization of pitch fabric, pitch mat, hybrid pitch/rayon fabric and pitch mat molding compound. With these properties determined an analytic capability now exists for predicting the thermal performance of these materials in rocket nozzle liner applications. Further planned efforts to verify material performance and analytical prediction procedures through actual rocket motor firings are also discussed.

  6. Exploring the potential of Multiphoton Laser Ablation Lithography (MP-LAL) as a reliable technique for sub-50nm patterning

    NASA Astrophysics Data System (ADS)

    Manouras, Theodoros; Angelakos, Evangelos; Vamvakaki, Maria; Argitis, Panagiotis

    2016-03-01

    In this work, direct-write, high-resolution multiphoton photolithography using doped random methacrylic co-polymer thin films is demonstrated, using a continuous wave ultraviolet (UV) 375 nm diode laser source. The random copolymers are specifically designed for enhancing resolution and addressing issues arising from laser ablation processes, such as the berm-formation around the created holes in the film, which can be accessed by tuning the polymeric material properties including Tg, surface adhesion etc. The methacrylic copolymer is composed of monomers, each of them especially selected to improve individual properties. The material formulations comprise perylene molecules absorbing at the exposure wavelength where the polymeric matrix is transparent. It was found that if the radiation intensity exceeds a certain threshold, the perylene molecules transfer the absorbed light energy to the acrylate polymer matrix leading to polymer degradation and ablation of the exposed areas. The non-linear nature of the light absorption and energy transfer processes resulted in the creation of holes with critical dimensions well below the used wavelength reaching the sub 50 nm domain. Arrays of holes having various dimensions were fabricated in the laser ablation experiments using a directwrite laser system developed specifically for the purposes of this project.

  7. Pulmonary Vein Stenosis Complicating Radiofrequency Catheter Ablation

    PubMed Central

    Lu, Hai-Wen; Wei, Ping; Jiang, Sen; Gu, Shu-yi; Fan, Li-Chao; liang, Shuo; Ji, Xiaobin; Rajbanshi, Bhavana; Xu, Jin-Fu

    2015-01-01

    Abstract The aim of this study is to characterize the clinical manifestations and features of pulmonary vein stenosis (PVS) by retrospectively analyzing clinical data of patients in addition to reviewing the literature simultaneously to improve the understanding of PVS complicating radiofrequency catheter ablation and to provide evidence for early diagnosis and timely treatment. Clinical, imaging, and follow-up data of 5 patients with PVS-complicating radiofrequency catheter ablation were retrospectively analyzed between January 2012 and December 2014 in Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China. Relevant studies previously reported were also reviewed. Three out of 5 patients received pulmonary angiography. The initial symptoms were not specific, presenting chest pain in 3 cases, hemoptysis in 2 cases. The average duration between radiofrequency ablation to the onset of symptoms was 5.8 months. The chest image results were consolidation and pleural effusion mainly. Veins distributed in the left lungs were mostly influenced in 4 patients, and the inferior veins in 3 patients. Cardiac ultrasound examinations showed pulmonary arterial hypertension in 2 patients. Two patients received selective bronchial artery embolization after bronchial artery radiography because of hemoptysis. One patient underwent video-assisted thoracoscopic biopsy because of the suspicion of tumor. PVS is a condition mostly undetected because of its silent manifestations and inconsistent follow-up. The accurate clinical diagnosis is very difficult. A careful review of medical history and follow-up observation may be useful for all the patients who received the radiofrequency catheter ablation to recognize PVS in the early stage. PMID:26313772

  8. A Review of Laser Ablation Propulsion

    SciTech Connect

    Phipps, Claude; Bohn, Willy; Lippert, Thomas; Sasoh, Akihiro; Schall, Wolfgang; Sinko, John

    2010-10-08

    Laser Ablation Propulsion is a broad field with a wide range of applications. We review the 30-year history of laser ablation propulsion from the transition from earlier pure photon propulsion concepts of Oberth and Saenger through Kantrowitz's original laser ablation propulsion idea to the development of air-breathing 'Lightcraft' and advanced spacecraft propulsion engines. The polymers POM and GAP have played an important role in experiments and liquid ablation fuels show great promise. Some applications use a laser system which is distant from the propelled object, for example, on another spacecraft, the Earth or a planet. Others use a laser that is part of the spacecraft propulsion system on the spacecraft. Propulsion is produced when an intense laser beam strikes a condensed matter surface and produces a vapor or plasma jet. The advantages of this idea are that exhaust velocity of the propulsion engine covers a broader range than is available from chemistry, that it can be varied to meet the instantaneous demands of the particular mission, and that practical realizations give lower mass and greater simplicity for a payload delivery system. We review the underlying theory, buttressed by extensive experimental data. The primary problem in laser space propulsion theory has been the absence of a way to predict thrust and specific impulse over the transition from the vapor to the plasma regimes. We briefly discuss a method for combining two new vapor regime treatments with plasma regime theory, giving a smooth transition from one regime to the other. We conclude with a section on future directions.

  9. Design Calculations For NIF Convergent Ablator Experiments

    SciTech Connect

    Olson, R E; Hicks, D G; Meezan, N B; Callahan, D A; Landen, O L; Jones, O S; Langer, S H; Kline, J L; Wilson, D C; Rinderknecht, H; Zylstra, A; Petrasso, R D

    2011-10-25

    The NIF convergent ablation tuning effort is underway. In the early experiments, we have discovered that the design code simulations over-predict the capsule implosion velocity and shock flash rhor, but under-predict the hohlraum x-ray flux measurements. The apparent inconsistency between the x-ray flux and radiography data implies that there are important unexplained aspects of the hohlraum and/or capsule behavior.

  10. Design calculations for NIF convergent ablator experiments

    NASA Astrophysics Data System (ADS)

    Olson, R. E.; Hicks, D. G.; Meezan, N. B.; Callahan, D. A.; Landen, O. L.; Jones, O. S.; Langer, S. H.; Kline, J. L.; Wilson, D. C.; Rinderknecht, H.; Zylstra, A.; Petrasso, R. D.

    2013-11-01

    The NIF convergent ablation tuning effort is underway. In the early experiments, we have discovered that the design code simulations over-predict the capsule implosion velocity and shock flash ρr, but under-predict the hohlraum x-ray flux measurements. The apparent inconsistency between the x-ray flux and radiography data implies that there are important unexplained aspects of the hohlraum and/or capsule behavior.

  11. Stability analysis of unsteady ablation fronts

    SciTech Connect

    Betti, R.; McCrory, R.L.; Verdon, C.P. )

    1993-11-08

    The linear stability analysis of unsteady ablation fronts is carried out for a semi-infinite uniform medium. For a laser accelerated target, it is shown that a properly selected modulation of the laser intensity can lead to the dynamic stabilization or growth-rate reduction of a large portion of the unstable spectrum. The theory is in qualitative agreement with the numerical results obtained by using the two-dimensional hydrodynamic code ORCHID.

  12. Stability analysis of unsteady ablation fronts

    NASA Astrophysics Data System (ADS)

    Betti, R.; McCrory, R. L.; Verdon, C. P.

    1993-08-01

    The linear stability analysis of unsteady ablation fronts is carried out for a semi-infinite uniform medium. For a laser accelerated target, it is shown that a properly selected modulation of the laser intensity can lead to the dynamic stabilization or growth-rate reduction of a large portion of the unstable spectrum. The theory is in qualitative agreement with the numerical results obtained by using the two-dimensional hydrodynamic code ORCHID.

  13. Stability analysis of unsteady ablation fronts

    SciTech Connect

    Betti, R.; McCrory, R.L.; Verdon, C.P.

    1993-08-01

    The linear stability analysis of unsteady ablation fronts, is carried out for a semi-infinite uniform medium. For a laser accelerated target, it is shown that a properly selected modulation of the laser intensity can lead to the dynamic stabilization or growth-rate reduction of a large portion of the unstable spectrum. The theory is in qualitative agreement with the numerical results obtained by using the two-dimensional hydrodynamic code ORCHID.

  14. Stability analysis of unsteady ablation fronts

    NASA Astrophysics Data System (ADS)

    Betti, R.; McCrory, R. L.; Verdon, C. P.

    1993-11-01

    The linear stability analysis of unsteady ablation fronts is carried out for a semi-infinite uniform medium. For a laser accelerated target, it is shown that a properly selected modulation of the laser intensity can lead to the dynamic stabilization or growth-rate reduction of a large portion of the unstable spectrum. The theory is in qualitative agreement with the numerical results obtained by using the two-dimensional hydrodynamic code orchid.

  15. A Review of Laser Ablation Propulsion

    NASA Astrophysics Data System (ADS)

    Phipps, Claude; Bohn, Willy; Lippert, Thomas; Sasoh, Akihiro; Schall, Wolfgang; Sinko, John

    2010-10-01

    Laser Ablation Propulsion is a broad field with a wide range of applications. We review the 30-year history of laser ablation propulsion from the transition from earlier pure photon propulsion concepts of Oberth and Sänger through Kantrowitz's original laser ablation propulsion idea to the development of air-breathing "Lightcraft" and advanced spacecraft propulsion engines. The polymers POM and GAP have played an important rôle in experiments and liquid ablation fuels show great promise. Some applications use a laser system which is distant from the propelled object, for example, on another spacecraft, the Earth or a planet. Others use a laser that is part of the spacecraft propulsion system on the spacecraft. Propulsion is produced when an intense laser beam strikes a condensed matter surface and produces a vapor or plasma jet. The advantages of this idea are that exhaust velocity of the propulsion engine covers a broader range than is available from chemistry, that it can be varied to meet the instantaneous demands of the particular mission, and that practical realizations give lower mass and greater simplicity for a payload delivery system. We review the underlying theory, buttressed by extensive experimental data. The primary problem in laser space propulsion theory has been the absence of a way to predict thrust and specific impulse over the transition from the vapor to the plasma regimes. We briefly discuss a method for combining two new vapor regime treatments with plasma regime theory, giving a smooth transition from one regime to the other. We conclude with a section on future directions.

  16. Study of the ablative effects on tektite

    NASA Technical Reports Server (NTRS)

    Chen, K. K.

    1975-01-01

    The tumbling and surface roughness effects on the trajectory of entry tektite are studied in both free molecular and continuum flows. It was concluded that, while surface roughness has negligible effect on trajectory, the tumbling may play an important role in tektite trajectory and the consequent ablation, provided the body shape is different from a sphere. A shape factor was a good parameter for correlations between body shape and tumbling effects.

  17. Enhanced Tissue Ablation Efficiency with a Mid-Infrared Nonlinear Frequency Conversion Laser System and Tissue Interaction Monitoring Using Optical Coherence Tomography

    PubMed Central

    Kim, Bongkyun; Kim, Dae Yu

    2016-01-01

    We report development of optical parametric oscillator (OPO)-based mid-infrared laser system that utilizes a periodically poled nonlinear crystal pumped by a near-infrared (NIR) laser. We obtained a mid-infrared average output of 8 W at an injection current of 20 A from a quasi-phase-matched OPO using an external cavity configuration. Laser tissue ablation efficiency is substantially affected by several parameters, including an optical fluence rate, wavelength of the laser source, and the optical properties of target tissue. Dimensions of wavelength and radiant exposure dependent tissue ablation are quantified using Fourier domain optical coherence tomography and the ablation efficiency was compared to a non-converted NIR laser system. PMID:27128916

  18. Enhanced Tissue Ablation Efficiency with a Mid-Infrared Nonlinear Frequency Conversion Laser System and Tissue Interaction Monitoring Using Optical Coherence Tomography.

    PubMed

    Kim, Bongkyun; Kim, Dae Yu

    2016-04-26

    We report development of optical parametric oscillator (OPO)-based mid-infrared laser system that utilizes a periodically poled nonlinear crystal pumped by a near-infrared (NIR) laser. We obtained a mid-infrared average output of 8 W at an injection current of 20 A from a quasi-phase-matched OPO using an external cavity configuration. Laser tissue ablation efficiency is substantially affected by several parameters, including an optical fluence rate, wavelength of the laser source, and the optical properties of target tissue. Dimensions of wavelength and radiant exposure dependent tissue ablation are quantified using Fourier domain optical coherence tomography and the ablation efficiency was compared to a non-converted NIR laser system.

  19. Classical Liquids in Fractal Dimension.

    PubMed

    Heinen, Marco; Schnyder, Simon K; Brady, John F; Löwen, Hartmut

    2015-08-28

    We introduce fractal liquids by generalizing classical liquids of integer dimensions d=1,2,3 to a noninteger dimension dl. The particles composing the liquid are fractal objects and their configuration space is also fractal, with the same dimension. Realizations of our generic model system include microphase separated binary liquids in porous media, and highly branched liquid droplets confined to a fractal polymer backbone in a gel. Here, we study the thermodynamics and pair correlations of fractal liquids by computer simulation and semianalytical statistical mechanics. Our results are based on a model where fractal hard spheres move on a near-critical percolating lattice cluster. The predictions of the fractal Percus-Yevick liquid integral equation compare well with our simulation results.

  20. Personality dimensions of opiate addicts.

    PubMed

    Vukov, M; Baba-Milkic, N; Lecic, D; Mijalkovic, S; Marinkovic, J

    1995-02-01

    A survey of 80 opiate addicts included in a detoxification program was conducted at the Institute on Addictions in Belgrade. In addition to a dependence diagnosis and mental disorders based on DSM-III-R, we applied a Tridimensional Personality Questionnaire (TPQ) that measures the 3 major personality dimensions: novelty-seeking (NS), harm avoidance (HA) and reward dependence (RD). When compared with a control group (a sample of Yugoslav undergraduate students), the opiate addicts demonstrate significantly high NS dimension as well as significant divergences of HA and RD subscales. The surveyed opiate addicts demonstrate a high percentage of personality disorders specifically in cluster B. The personality dimensions of opiate addicts showed certain temperament traits, such as: impulsiveness, shyness with strangers, fear of uncertainty and dependence. NS, HA and RD determined by temperament specifics may be an etiological factor in forming of a personality disorder, an affective disorder as well as of a drug choice.

  1. Collider searches for extra dimensions

    SciTech Connect

    Landsberg, Greg; /Brown U.

    2004-12-01

    Searches for extra spatial dimensions remain among the most popular new directions in our quest for physics beyond the Standard Model. High-energy collider experiments of the current decade should be able to find an ultimate answer to the question of their existence in a variety of models. Until the start of the LHC in a few years, the Tevatron will remain the key player in this quest. In this paper, we review the most recent results from the Tevatron on searches for large, TeV{sup -1}-size, and Randall-Sundrum extra spatial dimensions, which have reached a new level of sensitivity and currently probe the parameter space beyond the existing constraints. While no evidence for the existence of extra dimensions has been found so far, an exciting discovery might be just steps away.

  2. Correlated Electrons in Reduced Dimensions

    SciTech Connect

    Bonesteel, Nicholas E

    2015-01-31

    This report summarizes the work accomplished under the support of US DOE grant # DE-FG02-97ER45639, "Correlated Electrons in Reduced Dimensions." The underlying hypothesis of the research supported by this grant has been that studying the unique behavior of correlated electrons in reduced dimensions can lead to new ways of understanding how matter can order and how it can potentially be used. The systems under study have included i) fractional quantum Hall matter, which is realized when electrons are confined to two-dimensions and placed in a strong magnetic field at low temperature, ii) one-dimensional chains of spins and exotic quasiparticle excitations of topologically ordered matter, and iii) electrons confined in effectively ``zero-dimensional" semiconductor quantum dots.

  3. Microwave soft tissue ablation (Invited Paper)

    NASA Astrophysics Data System (ADS)

    Clegg, Peter J.; Cronin, Nigel J.

    2005-04-01

    Microsulis, in conjunction with the University of Bath have developed a set of novel microwave applicators for the ablation of soft tissues. These interstitial applicators have been designed for use in open surgical, laparoscopic and percutaneous settings and range in diameter from 2.4 to 7 mm. A 20 mm diameter flat faced interface applicator was developed as an adjunct to the open surgical interstitial applicator and has been applied to the treatment of surface breaking lesions in hepatobiliary surgery. Taken as a complete tool set the applicators are capable of treating a wide range of conditions in a safe and efficacious manner. The modality employs a radiated electromagnetic field at the allocated medical frequency of 2.45 GHz and powers between 30 and 150 Watts. Computer simulations, bench testing, safety and efficacy testing, ex-vivo and in-vivo work plus clinical trials have demonstrated that these systems are capable of generating large volumes of ablation in short times with favourable ablation geometries. Clinical studies have shown very low complication rates with minimal local recurrence. It is considered that this modality offers major advantages over currently marketed products. The technique is considered to be particularly safe as it is quick and there is no passage of current obviating the requirement for grounding pads. Since the microwave field operates primarily on water and all soft tissues with the exception of fat are made up of approximately 70% water the heating pattern is highly predictable making repeatability a key factor for this modality.

  4. Ultraviolet laser ablation of polyimide films

    NASA Astrophysics Data System (ADS)

    Srinivasan, R.; Braren, B.; Dreyfus, R. W.

    1987-01-01

    Pulsed laser radiation at 193, 248, or 308 nm can etch films of polyimide (DuPont KaptonTM). The mechanism of this process has been examined by the chemical analysis of the condensible products, by laser-induced fluorescence analysis of the diatomic products, and by the measurement of the etch depth per pulse over a range of fluences of the laser pulse. The most important product as well as the only one condensible at room temperature is carbon. Laser-induced fluorescence analysis showed that C2 and CN were present in the ablation plume. At 248 nm, even well below the fluence threshold of 0.08 J/cm2 for significant ablation, these diatomic species are readily detected and are measured to leave the polymer surface with translational energy of ˜5 eV. These results, when combined with the photoacoustic studies of Dyer and Srinivasan [Appl. Phys. Lett. 48, 445 (1986)], show that a simple photochemical mechanism in which one photon or less (on average) is absorbed per monomer is inadequate. The ablation process must involve many photons per monomer unit to account for the production of predominantly small (<4 atoms) products and the ejection of these fragments at supersonic velocities.

  5. KTP-532 laser ablation of urethral strictures

    NASA Astrophysics Data System (ADS)

    Malloy, Terrence R.

    1991-07-01

    In 1988, the KTP-532 laser was used to ablate a series of benign urethral strictures. Rather than using a single incision, as in urethrotomy, strictures were treated with a 360$DEG contact photoradiation. Thirty-one males, average age 53.2 years, received 37 treatments. Six patients underwent a second laser treatment. Stricture etiology was commonly iatrogenic (32%), traumatic (16%), and post-gonococcal (10%). Stricture location included mainly bulbar (49%), membranous (20%), and penile (12%) areas. The surgical technique consisted of a circumferential ablation followed by foley catheter placement (mean 10 days). Follow-up on 29 of 31 patients ranged from 1 to 16 months (mean 9.7) Complete success occurred in 17 patients (59%) who had no further symptoms or instrumentation. Partial success was seen in 6 patients (20.5%) with symptoms but no stricture recurrence. Six patients (20.5%) failed therapy requiring additional surgery or regular dilatations. No complications were encountered. Although longer assessment is required, KTP-532 laser ablation of urethral strictures appears efficacious.

  6. Transurethral radio frequency ablation of the prostate

    NASA Astrophysics Data System (ADS)

    Kabalin, John N.

    1996-05-01

    Since 1993, radiofrequency ablation of the prostate has been studied as a potential treatment for symptomatic bladder outlet obstruction due to benign prostatic hyperplasia. Two transurethral radiofrequency delivery systems have been developed to the point of undergoing initial human clinical trials. The TUNATM system involves focal interstitial radiofrequency energy application, while the TURAPYTM system involves a circumferential application of radiofrequency energy to the prostatic urethra via a simple delivery catheter. Experimental studies in animal models and human prostate tissue have demonstrated the nature of radiofrequency induced tissue heating and thermal injury. Observed thermal effects are relatively focused, with steep temperature gradients occurring over a few millimeters from the radiofrequency emission source. This allows precise and focused tissue treatment with little or no danger of injury to surrounding structures. Early human clinical experience in the treatment of benign prostatic hyperplasia has demonstrated efficacy in the relief of voiding symptoms and safety and minimal morbidity associated with this technology. The existing operative approaches are relatively simple. Ongoing development of more versatile delivery systems for radiofrequency ablation of the prostate is expected. Results from larger clinical trials with longer term followup will eventually allow adequate assessment of the role of radiofrequency ablation in the surgical management of benign prostatic hyperplasia.

  7. Laparoscopic ablation of symptomatic renal cysts.

    PubMed

    Rubenstein, S C; Hulbert, J C; Pharand, D; Schuessler, W W; Vancaillie, T G; Kavoussi, L R

    1993-10-01

    We report a laparoscopic approach to the drainage and ablation of symptomatic simple renal cysts. Ten patients with chronic pain, 6 of whom failed primary aspiration, underwent laparoscopic cyst ablation: 6 had solitary renal cysts, 3 had multiple cysts and 1 had a peripelvic cyst. The approach was transabdominal in 9 patients and extraperitoneal in 1. Intraoperatively, cyst fluid was obtained for cytological examination, and cyst walls were excised and sent for pathological examination. When possible, the remaining inner cyst walls were fulgurated to prevent recurrence. Mean total operating room time was 2 hours 27 minutes and blood loss was minimal. The sole complication was a postoperative retroperitoneal hematoma, which was managed conservatively. Malignancy was diagnosed in 2 patients, each of whom had a negative preoperative aspiration. These patients subsequently underwent radical nephrectomy. All remaining patients were asymptomatic at a mean followup of 10 months. Laparoscopic ablation of renal cysts is a safe and effective alternative to open surgery in patients who have failed conservative measures. Preoperative and intraoperative evaluation for malignancy should be performed.

  8. Ingrowing toenails: studies of segmental chemical ablation.

    PubMed

    Gem, M A; Sykes, P A

    1990-12-01

    Recent studies have suggested that segmental ablation is the treatment of choice for patients with ingrowing toenails and that the success rate is 96%. This procedure has been common practice among chiropodists for 20 years, usually using phenol in the United Kingdom, and sodium hydroxide in the United States. However, there has been little critical evaluation of the relative merits of the two chemicals, of the period of chemical application, or of the duration of post-operative pain and healing time. We therefore embarked upon a number of controlled prospective studies to examine these questions. A prospective study of 422 procedures for patients with ingrowing toenails (onychocryptosis) shows that good results are achieved by segmental chemical ablation performed by chiropodists in 91% of cases. The average period of post-operative pain is 3.6 days. Similar results are obtained using either 80% phenol or 10% sodium hydroxide. We believe that segmental chemical ablation by a chiropodist is the treatment of choice for the typical patient with an ingrowing toe nail. PMID:2102144

  9. Critical dimension: MEMS road map

    NASA Astrophysics Data System (ADS)

    Poulingue, Marc; Knutrud, Paul

    2007-03-01

    The use of Micro-Electro-Mechanical Systems (MEMS) technology in mechanical, biotechnology, optical, communications, and ink jet is growing. Critical dimensions in MEMS devices are getting smaller and processes are constantly facing new metrology challenges. This paper will examine some critical dimension metrology needs and challenges for MEMS using resist-on-silicon structures. It is shown that the use of automated optical CD metrology can meet emerging measurement requirements while bringing the advantages of a non-destructive, high throughput and precise methodology.

  10. Laser ablative cutting of ceramics for electronics applications

    SciTech Connect

    Warner, B. E., LLNL

    1996-03-01

    Pulsed, high-beam quality lasers offer unique materials processing characteristics. In processing metals, copper vapor and pulsed Nd:YAG lasers have produced micron-scale cuts and holes with submicron heat-affected zones. Since the cost of laser photons is high and average material removal rates can be slow with ablation, high value-added applications are necessary to justify processing costs. Ceramics present a special challenge for manufacturing because of their high hardness, relatively low thermal conductivity, and brittle nature. Surface damage typically limits the strength of a ceramic part to a small fraction of its bulk strength. This work investigates the use of copper vapor and pulsed diode-pumped Nd:YAG lasers to cut precision features in ceramic substrates. Variations in laser wavelength and power, processing speed, ceramic type, and assist gas were investigated with the goal of producing <100-{mu}m wide by 600-{mu}m deep cuts through silicon-carbide and alumina/titanium-carbide substrates for potential use in electronics. Silicon-carbide bars 250-{mu}m wide by 600-{mu}m high by 2.5-cm long were laser cut from substrates without fracture.

  11. Influence of the Liquid on Femtosecond Laser Ablation of Iron

    NASA Astrophysics Data System (ADS)

    Kanitz, A.; Hoppius, J. S.; Gurevich, E. L.; Ostendorf, A.

    Ultrashort pulse laser ablation has become a very important industrial method for highly precise material removal ranging from sensitive thin film processing to drilling and cutting of metals. Over the last decade, a new method to produce pure nanoparticles emerged from this technique: Pulsed Laser Ablation in Liquids (PLAL). By this method, the ablation of material by a laser beam is used to generate a metal vapor within the liquid in order to obtain nanoparticles from its recondensation process. It is well known that the liquid significantly alters the ablation properties of the substrate, in our case iron. For example, the ablation rate and crater morphology differ depending on the used liquid. We present our studies on the efficiency and quality of ablated grooves in water, methanol, acetone, ethanol and toluene. The produced grooves are investigated by means of white-light interferometry, EDX and SEM.

  12. Modeling CO{sub 2} Laser Ablative Impulse with Polymers

    SciTech Connect

    Sinko, John E.; Phipps, Claude R.; Sasoh, Akihiro

    2010-10-08

    Laser ablation vaporization models have usually ignored the spatial dependence of the laser beam. Here, we consider effects from modeling using a Gaussian beam for both photochemical and photothermal conditions. The modeling results are compared to experimental and literature data for CO{sub 2} laser ablation of the polymer polyoxymethylene under vacuum, and discussed in terms of the ablated mass areal density and momentum coupling coefficient. Extending the scope of discussion, laser ablative impulse generation research has lacked a cohesive strategy for linking the vaporization and plasma regimes. Existing models, mostly formulated for ultraviolet laser systems or metal targets, appear to be inappropriate or impractical for applications requiring CO{sub 2} laser ablation of polymers. A recently proposed method for linking the vaporization and plasma regimes for analytical modeling is addressed here along with the implications of its use. Key control parameters are considered, along with the major propulsion parameters needed for laser ablation propulsion modeling.

  13. How to Make an Active Zone: Unexpected Universal Functional Redundancy between RIMs and RIM-BPs.

    PubMed

    Acuna, Claudio; Liu, Xinran; Südhof, Thomas C

    2016-08-17

    RIMs and RIM-binding proteins (RBPs) are evolutionary conserved multidomain proteins of presynaptic active zones that are known to recruit Ca(2+) channels; in addition, RIMs perform well-recognized functions in tethering and priming synaptic vesicles for exocytosis. However, deletions of RIMs or RBPs in mice cause only partial impairments in various active zone functions and have no effect on active zone structure, as visualized by electron micrographs, suggesting that their contribution to active zone functions is limited. Here, we show in synapses of the calyx of Held in vivo and hippocampal neurons in culture that combined, but not individual, deletions of RIMs and RBPs eliminate tethering and priming of synaptic vesicles, deplete presynaptic Ca(2+) channels, and ablate active zone complexes, as analyzed by electron microscopy of chemically fixed synapses. Thus, RBPs perform unexpectedly broad roles at the active zone that together with those of RIMs are essential for all active zone functions. PMID:27537484

  14. How to Make an Active Zone: Unexpected Universal Functional Redundancy between RIMs and RIM-BPs.

    PubMed

    Acuna, Claudio; Liu, Xinran; Südhof, Thomas C

    2016-08-17

    RIMs and RIM-binding proteins (RBPs) are evolutionary conserved multidomain proteins of presynaptic active zones that are known to recruit Ca(2+) channels; in addition, RIMs perform well-recognized functions in tethering and priming synaptic vesicles for exocytosis. However, deletions of RIMs or RBPs in mice cause only partial impairments in various active zone functions and have no effect on active zone structure, as visualized by electron micrographs, suggesting that their contribution to active zone functions is limited. Here, we show in synapses of the calyx of Held in vivo and hippocampal neurons in culture that combined, but not individual, deletions of RIMs and RBPs eliminate tethering and priming of synaptic vesicles, deplete presynaptic Ca(2+) channels, and ablate active zone complexes, as analyzed by electron microscopy of chemically fixed synapses. Thus, RBPs perform unexpectedly broad roles at the active zone that together with those of RIMs are essential for all active zone functions.

  15. Distinguishing benign confounding treatment changes from residual prostate cancer on MRI following laser ablation

    NASA Astrophysics Data System (ADS)

    Litjens, G.; Huisman, H.; Elliott, R.; Shih, N.; Feldman, M.; Viswanath, S.; Fütterer, J.; Bomers, J.; Madabhushi, A.

    2014-03-01

    Laser interstitial thermotherapy (LITT) is a relatively new focal therapy technique for the ablation of localized prostate cancer. However, very little is known about the specific effects of LITT within the ablation zone and the surrounding normal tissue regions. For instance, it is important to be able to assess the extent of residual cancer within the prostate following LITT, which may be masked by thermally induced benign necrotic changes. Fortunately LITT is MRI compatible and hence this allows for quantitatively assessing LITT induced changes via multi-parametric MRI. Of course definite validation of any LITT induced changes on MRI requires confirmation via histopathology. The aim of this study was to quantitatively assess and distinguish the imaging characteristics of prostate cancer and benign confounding treatment changes following LITTon 3 Tesla multi-parametric MRI by carefully mapping the treatment related changes from the ex vivo surgically resected histopathologic specimens onto the pre-operative in vivo imaging. A better understanding of the imaging characteristics of residual disease and successfully ablated tissue might lead to improved treatment monitoring and as such patient prognosis. A unique clinical trial at the Radboud University Medical Center, in which 3 patients underwent a prostatectomy after LITT treatment, yielded ex-vivo histopathologic specimens along with pre- and post-LITT MRI. Using this data we (1) identified the computer extracted MRI signatures associated with treatment effects including benign necrotic changes and residual disease and (2) subsequently evaluated the computer extracted MRI features previously identified in distinguishing LITT induced changes in the ablated area relative to the residual disease. Towards this end first a pathologist annotated the ablated area and the residual disease on the ex-vivo histology and then we transferred the annotations to the post-LITT MRI using semi-automatic elastic registration. The

  16. Ablation by ultrashort laser pulses: Atomistic and thermodynamic analysis of the processes at the ablation threshold

    SciTech Connect

    Upadhyay, Arun K.; Inogamov, Nail A.; Rethfeld, Baerbel; Urbassek, Herbert M.

    2008-07-15

    Ultrafast laser irradiation of solids may ablate material off the surface. We study this process for thin films using molecular-dynamics simulation and thermodynamic analysis. Both metals and Lennard-Jones (LJ) materials are studied. We find that despite the large difference in thermodynamical properties between these two classes of materials--e.g., for aluminum versus LJ the ratio T{sub c}/T{sub tr} of critical to triple-point temperature differs by more than a factor of 4--the values of the ablation threshold energy E{sub abl} normalized to the cohesion energy, {epsilon}{sub abl}=E{sub abl}/E{sub coh}, are surprisingly universal: all are near 0.3 with {+-}30% scattering. The difference in the ratio T{sub c}/T{sub tr} means that for metals the melting threshold {epsilon}{sub m} is low, {epsilon}{sub m}<{epsilon}{sub abl}, while for LJ it is high, {epsilon}{sub m}>{epsilon}{sub abl}. This thermodynamical consideration gives a simple explanation for the difference between metals and LJ. It explains why despite the universality in {epsilon}{sub abl}, metals thermomechanically ablate always from the liquid state. This is opposite to LJ materials, which (near threshold) ablate from the solid state. Furthermore, we find that immediately below the ablation threshold, the formation of large voids (cavitation) in the irradiated material leads to a strong temporary expansion on a very slow time scale. This feature is easily distinguished from the acoustic oscillations governing the material response at smaller intensities, on the one hand, and the ablation occurring at larger intensities, on the other hand. This finding allows us to explain the puzzle of huge surface excursions found in experiments at near-threshold laser irradiation.

  17. Percutaneous ablation therapies of inoperable pancreatic cancer: a systematic review

    PubMed Central

    Ierardi, Anna Maria; Lucchina, Natalie; Bacuzzi, Alessandro; Marco, De Chiara; Bracchi, Elena; Cocozza, Eugenio; Dionigi, Gianlorenzo; Tsetis, Dimitrios; Floridi, Chiara; Carrafiello, Gianpaolo

    2015-01-01

    Initial studies about ablation therapies of the pancreas were associated with significant morbidity and mortality, which limited widespread adoption. Development of techniques with high quality imaging used as guidance improve outcomes reducing complications. Moreover, only few experiences of percutaneous pancreatic ablations are reported. They are performed by very skilled operators in highly specialized centers. This review presents the current status of percutaneous local ablative therapies in the treatment of advanced pancreatic cancer. PMID:26424487

  18. Thermal Protection during Percutaneous Thermal Ablation of Renal Cell Carcinoma

    PubMed Central

    Kam, Anthony W.; Littrup, Peter J.; Walther, McClellan M.; Hvizda, Julia; Wood, Bradford J.

    2008-01-01

    Thermal injury to collateral structures is a known complication of thermal ablation of tumors. The authors present the use of CO2 dissection and inserted balloons to protect the bowel during percutaneous radiofrequency (RF) ablation and cryotherapy of primary and locally recurrent renal cell carcinoma. These techniques offer the potential to increase the number of tumors that can be treated with RF ablation or cryotherapy from a percutaneous approach. PMID:15231890

  19. Focal Ablation of Prostate Cancer: Four Roles for MRI Guidance

    PubMed Central

    Sommer, Graham; Bouley, Donna; Gill, Harcharan; Daniel, Bruce; Pauly, Kim Butts; Diederich, Christopher

    2014-01-01

    Introduction There is currently a great deal of interest in the possible use of focal therapies for prostate cancer, since such treatments offer the prospect for control or cure of the primary disease with minimal side effects. Many forms of thermal therapy have been proposed for focal ablation of prostate cancer, including laser, high intensity ultrasound and cryotherapy. This review will demonstrate the important roles that MRI guidance can offer to such focal ablation, focusing on the use of high intensity ultrasonic applicators as an example of one promising technique. Materials and Methods Transurethral and interstitial high intensity ultrasonic applicators, designed specifically for ablation of prostate tissue were tested extensively in vivo in a canine model. The roles of MRI in positioning the devices, monitoring prostate ablation, and depicting ablated tissue were assessed using appropriate MRI sequences. Results MRI guidance provides a very effective tool for the positioning of ablative devices in the prostate, and thermal monitoring successfully predicted ablation of prostate tissue when a threshold of 52°C was achieved. Contrast enhanced MRI accurately depicted the distribution of ablated prostate tissue, which is resorbed at 30 days. Conclusions Guidance of thermal therapies for focal ablation of prostate cancer will likely prove critically dependent on MRI functioning in four separate roles. Our studies indicate that in 3 roles: device positioning; thermal monitoring of prostate ablation; and depiction of ablated prostate tissue, MR techniques are highly accurate and likely to be of great benefit in focal prostate cancer ablation. A fourth critical role, identification of cancer within the gland for targeting of thermal therapy, is more problematic at present, but will likely become practical with further technological advances. PMID:23587506

  20. [Successful ablation of an atrioventricular nodal reentrant tachycardia ablation 2 years after orthotopic heart transplantation].

    PubMed

    Bellmann, Barbara; Reith, Sebastian; Gemein, Christopher; Schauerte, Patrick

    2015-09-01

    We report the case of a 48-year-old woman with an orthotopic heart transplantation. Two years after transplantation, the patient reported intermittent palpitations and dyspnea. The results of the 12-lead electrogram provided suspicion of AV nodal reentrant tachycardia (AVNRT), which was confirmed in the electrophysiological examination. The AVNRT was successfully eliminated without complications by radiofrequency catheter ablation of the slow pathway. The case shows that an AVNRT, even with existing sinus rhythm of the original heart, can also occur on the transplanted heart and ablation is safe and feasible. PMID:26208808

  1. Young’s Modulus Reconstruction for Radio-frequency Ablation Electrode-induced Displacement Fields: A Feasibility Study

    PubMed Central

    Jiang, Jingfeng; Varghese, Tomy; Brace, Chris L.; Madsen, Ernest L.; Hall, Timothy J.; Bharat, Shyam; Hobson, Maritza A.; Zagzebski, James A.; Lee, Fred T.

    2009-01-01

    Radiofrequency (RF) ablation is a minimally invasive treatment for tumors in various abdominal organs. It is effective if good tumor localization and intra-procedural monitoring can be done. In this paper, we investigate the feasibility of using an ultrasound-based Young’s modulus reconstruction algorithm to image an ablated region whose stiffness is elevated due to tissue coagulation. To obtain controllable tissue deformations for abdominal organs during and/or intermediately after the RF ablation, the proposed modulus imaging method is specifically designed for using tissue deformation fields induced by the RF electrode. We have developed a new scheme under which the reconstruction problem is simplified to a two-dimensional problem. Based on this scheme, an iterative Young’s modulus reconstruction technique with edge-preserving regularization was developed to estimate the Young’s modulus distribution. The method was tested in experiments using a tissue-mimicking phantom and on ex vivo bovine liver tissues. Our preliminary results suggest that high contrast modulus images can be successfully reconstructed. In both experiments, the geometries of the reconstructed modulus images of thermal ablation zones match well with the phantom design and the gross pathology image, respectively. PMID:19258195

  2. Modelling of Indirect Laser-induced Thin-film Ablation of Epoxy for Local Exposing of Carbon Fibers

    NASA Astrophysics Data System (ADS)

    Emonts, Michael; Fischer, Kai; Schmitt, Stefan; Schares, Richard Ludwig

    Laser radiation is used as enabling technology for intrinsic joining of high-strength CFRP laminates and fiber-reinforced thermoplastic injection moulding compounds by exposure of surface-near carbon fibers. Short-pulsed NIR laser sources represent an acceptable compromise with respect to ablation performance, remote process capability by use of compact 3D scanner and the capability for closed-loop process control. However, using such a laser source means also minimizing heat-affected zones (HAZ). Based on literature research about laser ablation of thin metal films, heat flow at CFRP and thermo-mechanical behavior in FRP by pyrolysis, an analytical model was generated for thin-film ablation of cured epoxy resins at the surface of CFRP laminates by lift-off of resin chips. A comparison between simulation and experimental results confirms the capability of the model to predict the exposure area and the HAZ with deviations below 15%. Threshold fluences for the HAZ (>1 J/cm2) and the resin ablation (>3 J/cm2) have been confirmed.

  3. Nanochemical effects in femtosecond laser ablation of metals

    SciTech Connect

    Vorobyev, A. Y.; Guo, Chunlei

    2013-02-18

    We study chemical energy released from the oxidation of aluminum in multipulse femtosecond laser ablation in air and oxygen. Our study shows that the released chemical energy amounts to about 13% of the incident laser energy, and about 50% of the ablated material is oxidized. The ablated material mass per laser pulse is measured to be on the nanogram scale. Our study indicates that femtosecond laser ablation is capable of inducing nanochemical reactions since the femtosecond laser pulse can controllably produce nanoparticles, clusters, and atoms from a solid target.

  4. Stability of a Shock-Decelerated Ablation Front

    SciTech Connect

    Aglitskiy, Y.; Karasik, M.; Velikovich, A. L.; Serlin, V.; Weaver, J. L.; Schmitt, A. J.; Obenschain, S. P.; Metzler, N.; Zalesak, S. T.; Gardner, J. H.; Oh, J.; Harding, E. C.

    2009-08-21

    Experimental study of a shock-decelerated ablation front is reported. A planar solid plastic target is accelerated by a laser across a vacuum gap and collides with a lower-density plastic foam layer. While the target is accelerated, a fast Rayleigh-Taylor (RT) growth of the seeded single-mode perturbation at the ablation front is observed. After the collision, the velocity of the ablation front is seen to remain constant. The reshock quenches the RT growth but does not trigger any Richtmyer-Meshkov growth at the ablation front, which is shown to be consistent with both theory and simulations.

  5. Wavefront control of optical components by laser-ablative figuring

    NASA Astrophysics Data System (ADS)

    Jitsuno, Takahisa; Akashi, Tomoyoshi; Nakatsuka, Masahiro; Nakai, Sadao; Tokumura, Keiu

    1997-12-01

    A new method for figuring the surface profile of optical plastics and optical glass have been proposed and demonstrated. An ArF excimer laser is used to ablate very thin layer of the surface of the substrates. The shape of the ablated surface is monitored by an interferometer in site condition. The ablation rate of PMMA is 0.08 micrometers per pulse at the energy density of 50 mJ/cm2. The optical glass (BK-7) can be ablated 0.15 micrometers per pulse at the fluence of 1.5 J/cm2.

  6. Recent Advances in Tumor Ablation for Hepatocellular Carcinoma.

    PubMed

    Kang, Tae Wook; Rhim, Hyunchul

    2015-09-01

    Image-guided tumor ablation for early stage hepatocellular carcinoma (HCC) is an accepted non-surgical treatment that provides excellent local tumor control and favorable survival benefit. This review summarizes the recent advances in tumor ablation for HCC. Diagnostic imaging and molecular biology of HCC has recently undergone marked improvements. Second-generation ultrasonography (US) contrast agents, new computed tomography (CT) techniques, and liver-specific contrast agents for magnetic resonance imaging (MRI) have enabled the early detection of smaller and inconspicuous HCC lesions. Various imaging-guidance tools that incorporate imaging-fusion between real-time US and CT/MRI, that are now common for percutaneous tumor ablation, have increased operator confidence in the accurate targeting of technically difficult tumors. In addition to radiofrequency ablation (RFA), various therapeutic modalities including microwave ablation, irreversible electroporation, and high-intensity focused ultrasound ablation have attracted attention as alternative energy sources for effective locoregional treatment of HCC. In addition, combined treatment with RFA and chemoembolization or molecular agents may be able to overcome the limitation of advanced or large tumors. Finally, understanding of the biological mechanisms and advances in therapy associated with tumor ablation will be important for successful tumor control. All these advances in tumor ablation for HCC will result in significant improvement in the prognosis of HCC patients. In this review, we primarily focus on recent advances in molecular tumor biology, diagnosis, imaging-guidance tools, and therapeutic modalities, and refer to the current status and future perspectives for tumor ablation for HCC.

  7. Osteoid Osteoma: Experience with Laser- and Radiofrequency-Induced Ablation

    SciTech Connect

    Gebauer, Bernhard Tunn, Per-Ulf; Gaffke, Gunnar; Melcher, Ingo; Felix, Roland; Stroszczynski, Christian

    2006-04-15

    The purpose of this study was to analyze the clinical outcome of osteoid osteoma treated by thermal ablation after drill opening. A total of 17 patients and 20 procedures were included. All patients had typical clinical features (age, pain) and a typical radiograph showing a nidus. In 5 cases, additional histological specimens were acquired. After drill opening of the osteoid osteoma nidus, 12 thermal ablations were induced by laser interstitial thermal therapy (LITT) (9F Power-Laser-Set; Somatex, Germany) and 8 ablations by radiofrequency ablation (RFA) (RITA; StarBurst, USA). Initial clinical success with pain relief has been achieved in all patients after the first ablation. Three patients had an osteoid osteoma recurrence after 3, 9, and 10 months and were successfully re-treated by thermal ablation. No major complication and one minor complication (sensible defect) were recorded. Thermal ablation is a safe and minimally invasive therapy option for osteoid osteoma. Although the groups are too small for a comparative analysis, we determined no difference between laser- and radiofrequency-induced ablation in clinical outcome after ablation.

  8. Image-Guided Tumor Ablation: Emerging Technologies and Future Directions

    PubMed Central

    McWilliams, Justin P.; Lee, Edward W.; Yamamoto, Shota; Loh, Christopher T.; Kee, Stephen T.

    2010-01-01

    As the trend continues toward the decreased invasiveness of medical procedures, image-guided percutaneous ablation has begun to supplant surgery for the local control of small tumors in the liver, kidney, and lung. New ablation technologies, and refinements of existing technologies, will enable treatment of larger and more complex tumors in these and other organs. At the same time, improvements in intraprocedural imaging promise to improve treatment accuracy and reduce complications. In this review, the latest advancements in clinical and experimental ablation technologies will be summarized, and new applications of image-guided tumor ablation will be discussed. PMID:22550370

  9. Transcatheter and ablative therapeutic approaches for solid malignancies.

    PubMed

    Liapi, Eleni; Geschwind, Jean-Francois H

    2007-03-10

    The purpose of this article is to present in a concise manner an overview of the most widely used locoregional transcatheter and ablative therapies for solid malignancies. An extensive MEDLINE search was performed for this review. Therapies used for liver cancer were emphasized because these therapies are used most commonly in the liver. Applications in pulmonary, renal, and bone tumors were also discussed. These approaches were divided into catheter-based therapies (such as transcatheter arterial chemoembolization, bland embolization, and the most recent transcatheter arterial approach with drug-eluting microspheres), ablative therapies (such as chemical [ethanol or acetic acid injection]), and thermal ablative therapies (such as radiofrequency ablation, laser induced thermotherapy, microwave ablation, cryoablation, and extracorporeal high-intensity focused ultrasound ablation). A brief description of each technique and analysis of available data was reported for all therapies. Locoregional transcatheter and ablative therapies continue to be used mostly for palliation, but have also been used with curative intent. A growing body of evidence suggests clear survival benefit, excellent results regarding local tumor control, and improved quality of life. Clinical trials are underway to validate these results. Image-guided transcatheter and ablative approaches currently play an important role in the management of patients with various types of cancer-a role that is likely to grow even more given the technological advances in imaging, image-guidance systems, catheters, ablative tools, and drug delivery systems. As a result, the outcomes of patients with cancer undoubtedly will improve.

  10. Dimensions of Interpersonal Relationships Revisited.

    ERIC Educational Resources Information Center

    Wiemann, John M.; Krueger, Dorothy Lenk

    The ways in which people described their own interpersonal relationships were examined along the universally acknowledged relational dimensions control and affiliation. A total of 216 undergraduate communication students wrote about one of three types of relationships they had: best liked friend of the opposite sex, (60), best liked friend of the…

  11. Dimension independence in exterior algebra.

    PubMed Central

    Hawrylycz, M

    1995-01-01

    The identities between homogeneous expressions in rank 1 vectors and rank n - 1 covectors in a Grassmann-Cayley algebra of rank n, in which one set occurs multilinearly, are shown to represent a set of dimension-independent identities. The theorem yields an infinite set of nontrivial geometric identities from a given identity. PMID:11607520

  12. The Visuospatial Dimension of Writing

    ERIC Educational Resources Information Center

    Olive, Thierry; Passerault, Jean-Michel

    2012-01-01

    The authors suggest that writing should be conceived of not only as a verbal activity but also as a visuospatial activity, in which writers process and construct visuospatial mental representations. After briefly describing research on visuospatial cognition, they look at how cognitive researchers have investigated the visuospatial dimension of…

  13. The European Dimension in Education.

    ERIC Educational Resources Information Center

    Council of Europe, Strasbourg (France). Directorate of Education, Culture and Sport, Documentation Section.

    This paper addresses concerns about a European dimension in education that has been created by the enlargement of the European Union (EU) (the inclusion of Austria, Finland, and Sweden) and the gradual transformations of institutions into a future federal state. Sections of the paper include: (1) "Introduction"; (2) "Defining the European…

  14. Heat conduction in three dimensions

    NASA Technical Reports Server (NTRS)

    Danza, T. M.; Fesler, L. W.; Mongan, R. D.

    1980-01-01

    Multidimensional heat conduction program computes transient temperature history and steady state temperatures of complex body geometries in three dimensions. Emphasis is placed on type of problems associated with Space Shuttle thermal protection system, but program could be used in thermal analysis of most three dimensional systems.

  15. Temporal Trends in the Histology of the Rabbit Kidney after Cavitational Tissue Ablation

    NASA Astrophysics Data System (ADS)

    Hall, Timothy L.; Kieran, Kathleen; Fowlkes, J. Brian; Cain, Charles A.; Roberts, William W.

    2007-05-01

    Tissue can be mechanically ablated through inertial cavitation generated by high intensity pulsed ultrasound. The ablation appears acutely as a fine slurry with absent cellular structure. Long-term effects and the evolution of histologic changes in disrupted tissue remain poorly understood. This study aimed to characterize the 0-60 day histology of cavitational ablation in a rabbit model. 29 New Zealand White rabbits were anesthetized and exposed to high intensity pulses of ultrasound (60000 pulses, 20 usec duration, 750 kHz, 1 kHz PRF, 18 MPa peak rarefactional pressure, lower pole, left kidney). Kidneys were harvested immediately from five rabbits. The others were recovered and the kidneys were harvested 1, 2, 7, 20, or 60 days after treatment. Grossly, kidneys from 0-2 days displayed subcapsular bruising near the exposure site and some hemorrhage in the adjacent perirenal fat; microscopically, a disrupted, acellular zone measuring 3-5 mm by 5-10 mm accompanied by local infiltration of neutrophils (acute inflammation) was seen. Kidneys harvested after 7 days displayed tubular dilatation adjacent to the targeted area and collagen deposition consistent with scar formation. Decreased collagen deposition, decreased size of the disrupted zone, and regeneration of the tubular basal cell layer of dilated tubules was evident by day 20. Kidneys harvested at 20 and 60 days had contour defects near the exposure site with an apparent volume loss. Cavitation causes orderly and predictable histologic changes. Local renal damage induced during histotripsy may be partially reversible. Further research is needed to identify the clinical correlates of the observed histologic findings.

  16. Association of computerized texture features on MRI with early treatment response following laser ablation for neuropathic cancer pain: preliminary findings.

    PubMed

    Tiwari, Pallavi; Danish, Shabbar F; Jiang, Benjamin; Madabhushi, Anant

    2015-10-01

    Laser interstitial thermal therapy (LITT) has recently emerged as a new treatment modality for cancer pain management that targets the cingulum (pain center in the brain) and has shown promise over radio frequency (RF)-based ablation, due to magnetic resonance image (MRI) guidance that allows for precise ablation. Since laser ablation for pain management is currently exploratory and is only performed at a few centers worldwide, its short- and long-term effects on the cingulum are currently unknown. Traditionally, treatment effects for neurological conditions are evaluated by monitoring changes in intensities and/or volume of the ablation zone on post-treatment Gadolinium-contrast T1-w (Gd-T1) MRI. However, LITT introduces subtle localized changes corresponding to tissues response to treatment, which may not be appreciable on visual inspection of volumetric or intensity changes. Additionally, different MRI protocols [Gd-T1, T2w, gradient echo sequence (GRE), fluid-attenuated inversion recovery (FLAIR)] are known to capture complementary diagnostic information regarding the patient's response to treatment; the utility of these MRI protocols has so far not been investigated to evaluate early and localized response to LITT treatment in the context of neuropathic cancer pain. In this work, we present the first attempt at (a) examining early treatment-related changes on a per-voxel basis via quantitative comparison of computer-extracted texture descriptors across pre- and post-LITT multiparametric (MP-MRI) (Gd-T1, T2w, GRE, FLAIR), subtle microarchitectural texture changes that may not be appreciable on original MR intensities or volumetric differences, and (b) investigating the efficacy of different MRI protocols in accurately capturing immediate post-treatment changes reflected (1) within and (2) outside the ablation zone. A retrospective cohort of four patient studies comprising pre- and immediate (24 h) post-LITT 3 Tesla Gd-T1, T2w, GRE, and FLAIR acquisitions

  17. Vadose zone microbiology

    SciTech Connect

    Kieft, Thomas L.; Brockman, Fred J.

    2001-01-17

    The vadose zone is defined as the portion of the terrestrial subsurface that extends from the land surface downward to the water table. As such, it comprises the surface soil (the rooting zone), the underlying subsoil, and the capillary fringe that directly overlies the water table. The unsaturated zone between the rooting zone and the capillary fringe is termed the "intermediate zone" (Chapelle, 1993). The vadose zone has also been defined as the unsaturated zone, since the sediment pores and/or rock fractures are generally not completely water filled, but instead contain both water and air. The latter characteristic results in the term "zone of aeration" to describe the vadose zone. The terms "vadose zone," "unsaturated zone", and "zone of aeration" are nearly synonymous, except that the vadose zone may contain regions of perched water that are actually saturated. The term "subsoil" has also been used for studies of shallow areas of the subsurface immediately below the rooting zone. This review focuses almost exclusively on the unsaturated region beneath the soil layer since there is already an extensive body of literature on surface soil microbial communities and process, e.g., Paul and Clark (1989), Metting (1993), Richter and Markowitz, (1995), and Sylvia et al. (1998); whereas the deeper strata of the unsaturated zone have only recently come under scrutiny for their microbiological properties.

  18. Automatic alignment of pre- and post-interventional liver CT images for assessment of radiofrequency ablation

    NASA Astrophysics Data System (ADS)

    Rieder, Christian; Wirtz, Stefan; Strehlow, Jan; Zidowitz, Stephan; Bruners, Philipp; Isfort, Peter; Mahnken, Andreas H.; Peitgen, Heinz-Otto

    2012-02-01

    Image-guided radiofrequency ablation (RFA) is becoming a standard procedure for minimally invasive tumor treatment in clinical practice. To verify the treatment success of the therapy, reliable post-interventional assessment of the ablation zone (coagulation) is essential. Typically, pre- and post-interventional CT images have to be aligned to compare the shape, size, and position of tumor and coagulation zone. In this work, we present an automatic workflow for masking liver tissue, enabling a rigid registration algorithm to perform at least as accurate as experienced medical experts. To minimize the effect of global liver deformations, the registration is computed in a local region of interest around the pre-interventional lesion and post-interventional coagulation necrosis. A registration mask excluding lesions and neighboring organs is calculated to prevent the registration algorithm from matching both lesion shapes instead of the surrounding liver anatomy. As an initial registration step, the centers of gravity from both lesions are aligned automatically. The subsequent rigid registration method is based on the Local Cross Correlation (LCC) similarity measure and Newton-type optimization. To assess the accuracy of our method, 41 RFA cases are registered and compared with the manually aligned cases from four medical experts. Furthermore, the registration results are compared with ground truth transformations based on averaged anatomical landmark pairs. In the evaluation, we show that our method allows to automatic alignment of the data sets with equal accuracy as medical experts, but requiring significancy less time consumption and variability.

  19. CT-guided Bipolar and Multipolar Radiofrequency Ablation (RF Ablation) of Renal Cell Carcinoma: Specific Technical Aspects and Clinical Results

    SciTech Connect

    Sommer, C. M.; Lemm, G.; Hohenstein, E.; Bellemann, N.; Stampfl, U.; Goezen, A. S.; Rassweiler, J.; Kauczor, H. U.; Radeleff, B. A.; Pereira, P. L.

    2013-06-15

    Purpose. This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. Methods. We included 22 consecutive patients (3 women; age 74.2 {+-} 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 {+-} 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. Results. Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 {+-} 13.6 min and 43.7 {+-} 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 {+-} 8.8 months, local recurrence-free survival was 14.4 {+-} 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 {+-} 16.6 ml/min/1.73 m{sup 2} before RF ablation vs. 47.2 {+-} 11.9 ml/min/1.73 m{sup 2} after RF ablation; not significant). Conclusions. CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.

  20. Interaction between pregnancy zone protein and plasmin.

    PubMed

    Poulsen, O M; Hau, J

    1988-01-01

    Pregnancy zone protein (PZP, alpha 2-PAG, SP3) was found to bind to plasmin in crossed affino-immunoelectrophoresis using sodium caseinate in the first dimension gel. The plasmin presence in the PZP-plasmin complex was confirmed by addition of antiserum against plasminogen to the gel. In crossed affino-immunoelectrophoresis using plasmin in the first dimension gel a non migrative PZP immunoreactive peak appeared, similar to the peak obtained with casein in the first dimension gel. Incubation of mixtures of PZP and plasmin also demonstrated complex formation between PZP and plasmin. The complex between PZP and plasmin could be precipitated not only by anti-PZP antibodies, but also by anti-plasminogen antibodies, confirming the interaction between the two molecules. The significance of the binding between plasmin and PZP remains to be elucidated, but it is tempting to speculate that PZP, present on the trophoblastic surface, immobilizes plasmin, rendering this molecule able to perform a local fibrinolytic activity.

  1. A Miniature Forward-imaging B-scan Optical Coherence Tomography Probe to Guide Real-time Laser Ablation

    PubMed Central

    Li, Zhuoyan; Shen, Jin H.; Kozub, John A.; Prasad, Ratna; Lu, Pengcheng; Joos, Karen M.

    2014-01-01

    Background and Objective Investigations have shown that pulsed lasers tuned to 6.1 μm in wavelength are capable of ablating ocular and neural tissue with minimal collateral damage. This study investigated whether a miniature B-scan forward-imaging optical coherence tomography (OCT) probe can be combined with the laser to provide real-time visual feedback during laser incisions. Study Design/Methods and Materials A miniature 25-gauge B-scan forward-imaging OCT probe was developed and combined with a 250 μm hollow-glass waveguide to permit delivery of 6.1 μm laser energy. A gelatin mixture and both porcine corneal and retinal tissues were simultaneously imaged and lased (6.1 μm, 10 Hz, 0.4-0.7 mJ) through air. The ablation studies were observed and recorded in real time. The crater dimensions were measured using OCT imaging software (Bioptigen, Durham, NC). Histological analysis was performed on the ocular tissues. Results The combined miniature forward-imaging OCT and mid-infrared laser-delivery probe successfully imaged real-time tissue ablation in gelatin, corneal tissue, and retinal tissue. Application of a constant number of 60 pulses at 0.5 mJ/pulse to the gelatin resulted in a mean crater depth of 123 ± 15 μm. For the corneal tissue, there was a significant correlation between the number of pulses used and depth of the lased hole (Pearson correlation coefficient = 0.82; P = 0.0002). Histological analysis of the cornea and retina tissues showed discrete holes with minimal thermal damage. Conclusions A combined miniature OCT and laser -delivery probe can monitor real-time tissue laser ablation. With additional testing and improvements, this novel instrument has the future possibility of effectively guiding surgeries by simultaneously imaging and ablating tissue. PMID:24648326

  2. Characterising Complex Ice-Tephra Spatial Feedbacks of Post-Volcanic Eruption Glacial Ablation Using Terrestrial Laser Scanning

    NASA Astrophysics Data System (ADS)

    Vircavs, L.; Nield, J. M.; Chiverrell, R. C.; Darby, S. E.; Leyland, J.; Jacobs, B.

    2012-12-01

    Volcanic eruptions in glacio-volcanic regions regularly deposit significant quantities of volcanic ash (tephra) over nearby glaciers. This ash debris can remain for decades as it is transported through the system and has the ability to alter surface albedo, thermal insulation and ultimately surface roughness which can significantly modify the glacial response to climate perturbations. We used terrestrial laser scanning (TLS) to measure daily ice-ash surface interactions for a week in July 2011 following tephra fallout from the May 2011 Grímsvötn eruption onto Svínafellsjökull, Iceland. TLS is well suited to process studies and enabled repeat measurements to be collected of ice surface topography and signal absorption at high spatial resolution in three dimensions rather than traditional transect type studies. Our data confirm ablation rates either reduce or increase under thick (insulating) and thin (reduced albedo) ash deposits, respectively. Fourier transform analysis of the TLS data identified that a three-fold increase in aerodynamic roughness was attributable to an increase in larger (>0.2m) surface features. These surface features include micro cryoconite holes, debris cones and meltwater channels. Moreover, the temporal sequence of TLS measurements revealed the importance of ash redistribution by meltwater in generating differential melting which then modifies roughness and ash patchiness, such that the net effect of these spatial ash-ice feedbacks was to reduce ablation rates by up to 59%. This reduction in ablation rates despite increases in temperature and solar radiation was confirmed by manual stake measurements and is the reverse of modelled ablation trends without surficial ash. The modulating effects of these previously undocumented ash-ice feedbacks on ablation rates are, therefore, significant and must be correctly parameterized if ash-covered glacier mass balances are to be predicted correctly.

  3. Impairment of radial glial scaffold-dependent neuronal migration and formation of double cortex by genetic ablation of afadin.

    PubMed

    Yamamoto, Hideaki; Mandai, Kenji; Konno, Daijiro; Maruo, Tomohiko; Matsuzaki, Fumio; Takai, Yoshimi

    2015-09-16

    Studies of human brain malformations, such as lissencephaly and double cortex, have revealed the importance of neuronal migration during cortical development. Afadin, a membrane scaffolding protein, regulates the formation of adherens junctions (AJs) and cell migration to form and maintain tissue structures. Here, we report that mice with dorsal telencephalon-specific ablation of afadin gene exhibited defects similar to human double cortex, in which the heterotopic cortex was located underneath the normotopic cortex. The normotopic cortex of the mutant mice was arranged in the pattern similar to the cortex of the control mice, while the heterotopic cortex was disorganized. As seen in human patients, double cortex in the mutant mice was formed by impaired neuronal migration during cortical development. Genetic ablation of afadin in the embryonic cerebral cortex disrupted AJs of radial glial cells, likely resulting in the retraction of the apical endfeet from the ventricular surface and the dispersion of radial glial cells from the ventricular zone to the subventricular and intermediate zones. These results indicate that afadin is required for the maintenance of AJs of radial glial cells and that the disruption of AJs might cause an abnormal radial scaffold for neuronal migration. In contrast, the proliferation or differentiation of radial glial cells was not significantly affected. Taken together, these findings indicate that afadin is required for the maintenance of the radial glial scaffold for neuronal migration and that the genetic ablation of afadin leads to the formation of double cortex.

  4. Mechanism study of skin tissue ablation by nanosecond laser pulses

    NASA Astrophysics Data System (ADS)

    Fang, Qiyin

    Understanding the fundamental mechanisms in laser tissue ablation is essential to improve clinical laser applications by reducing collateral damage and laser pulse energy requirement. The motive of this dissertation is to study skin tissue ablation by nanosecond laser pulses in a wide spectral region from near-infrared to ultraviolet for a clear understanding of the mechanism that can be used to improve future design of the pulsed lasers for dermatology and plastic surgery. Multiple laser and optical configurations have been constructed to generate 9 to 12ns laser pulses with similar profiles at 1064. 532, 266 and 213nm for this study of skin tissue ablation. Through measurements of ablation depth as a function cf laser pulse energy, the 589nm spectral line in the secondary radiation from ablated skin tissue samples was identified as the signature of the occurrence of ablation. Subsequently, this spectral signature has been used to investigate the probabilistic process of the ablation near the threshold at the four wavelengths. Measurements of the ablation probability were conducted as a function of the electrical field strength of the laser pulse and the ablation thresholds in a wide spectral range from 1064nm to 213nm were determined. Histology analysis and an optical transmission method were applied in assessing of the ablation depth per pulse to study the ablation process at irradiance levels higher than threshold. Because more than 70% of the wet weight of the skin tissue is water, optical breakdown and backscattering in water was also investigated along with a nonlinear refraction index measurement using a z-scan technique. Preliminary studies on ablation of a gelatin based tissue phantom are also reported. The current theoretical models describing ablation of soft tissue ablation by short laser pulses were critically reviewed. Since none of the existing models was found capable of explaining the experimental results, a new plasma-mediated model was developed

  5. Metal particles produced by laser ablation for ICP-MSmeasurements

    SciTech Connect

    Gonzalez, Jhanis J.; Liu, Chunyi; Wen, Sy-Bor; Mao, Xianglei; Russo, Richard E.

    2007-06-01

    Pulsed laser ablation (266nm) was used to generate metal particles of Zn and Al alloys using femtosecond (150 fs) and nanosecond (4 ns) laser pulses with identical fluences of 50 J cm{sup -2}. Characterization of particles and correlation with Inductively Coupled Plasma Mass Spectrometer (ICP-MS) performance was investigated. Particles produced by nanosecond laser ablation were mainly primary particles with irregular shape and hard agglomerates (without internal voids). Particles produced by femtosecond laser ablation consisted of spherical primary particles and soft agglomerates formed from numerous small particles. Examination of the craters by white light interferometric microscopy showed that there is a rim of material surrounding the craters formed after nanosecond laser ablation. The determination of the crater volume by white light interferometric microscopy, considering the rim of material surrounding ablation craters, revealed that the volume ratio (fs/ns) of the craters on the selected samples was approximately 9 (Zn), 7 (NIST627 alloy) and 5 (NIST1711 alloy) times more ablated mass with femtosecond pulsed ablation compared to nanosecond pulsed ablation. In addition, an increase of Al concentration from 0 to 5% in Zn base alloys caused a large increase in the diameter of the particles, up to 65% while using nanosecond laser pulses. When the ablated particles were carried in argon into an ICP-MS, the Zn and Al signals intensities were greater by factors of {approx} 50 and {approx} 12 for fs vs. ns ablation. Femtosecond pulsed ablation also reduced temporal fluctuations in the {sup 66}Zn transient signal by a factor of ten compared to nanosecond laser pulses.

  6. Catheter Ablation for Long-Standing Persistent Atrial Fibrillation.

    PubMed

    Romero, Jorge; Gianni, Carola; Di Biase, Luigi; Natale, Andrea

    2015-01-01

    Atrial fibrillation (AF) is the most common sustained arrhythmia worldwide and represents a major burden to health care systems. Atrial fibrillation is associated with a 4- to 5-fold increased risk of thromboembolic stroke. The pulmonary veins have been identified as major sources of atrial triggers for AF. This is particularly true in patients with paroxysmal AF but not always the case for those with long-standing persistent AF (LSPAF), in which other locations for ectopic beats have been well recognized. Structures with foci triggering AF include the coronary sinus, the left atrial appendage (LAA), the superior vena cava, the crista terminalis, and the ligament of Marshall. More than 30 studies reporting results on radiofrequency ablation of LSPAF have been published to date. Most of these are observational studies with very different methodologies using different strategies. As a result, there has been remarkable variation in short- and long-term success, which suggests that the optimal ablation technique for LSPAF is still to be elucidated. In this review we discuss the different approaches to LSPAF catheter ablation, starting with pulmonary vein isolation (PVI) through ablation lines in different left atrial locations, the role of complex fractionated atrial electrograms, focal impulses and rotor modulation, autonomic modulation (ganglionated plexi), alcohol ablation, and the future of epicardial mapping and ablation for this arrhythmia. A stepwise ablation approach requires several key ablation techniques, such as meticulous PVI, linear ablation at the roof and mitral isthmus, electrogram-targeted ablation with particular attention to triggers in the coronary sinus and LAA, and discretionary right atrial ablation (superior vena cava, intercaval, or cavotricuspid isthmus lines). PMID:26306125

  7. Catheter Ablation for Long-Standing Persistent Atrial Fibrillation

    PubMed Central

    Romero, Jorge; Gianni, Carola; Di Biase, Luigi; Natale, Andrea

    2015-01-01

    Atrial fibrillation (AF) is the most common sustained arrhythmia worldwide and represents a major burden to health care systems. Atrial fibrillation is associated with a 4- to 5-fold increased risk of thromboembolic stroke. The pulmonary veins have been identified as major sources of atrial triggers for AF. This is particularly true in patients with paroxysmal AF but not always the case for those with long-standing persistent AF (LSPAF), in which other locations for ectopic beats have been well recognized. Structures with foci triggering AF include the coronary sinus, the left atrial appendage (LAA), the superior vena cava, the crista terminalis, and the ligament of Marshall. More than 30 studies reporting results on radiofrequency ablation of LSPAF have been published to date. Most of these are observational studies with very different methodologies using different strategies. As a result, there has been remarkable variation in short- and long-term success, which suggests that the optimal ablation technique for LSPAF is still to be elucidated. In this review we discuss the different approaches to LSPAF catheter ablation, starting with pulmonary vein isolation (PVI) through ablation lines in different left atrial locations, the role of complex fractionated atrial electrograms, focal impulses and rotor modulation, autonomic modulation (ganglionated plexi), alcohol ablation, and the future of epicardial mapping and ablation for this arrhythmia. A stepwise ablation approach requires several key ablation techniques, such as meticulous PVI, linear ablation at the roof and mitral isthmus, electrogram-targeted ablation with particular attention to triggers in the coronary sinus and LAA, and discretionary right atrial ablation (superior vena cava, intercaval, or cavotricuspid isthmus lines). PMID:26306125

  8. Similarities and differences in ablative and non-ablative iron oxide nanoparticle hyperthermia cancer treatment

    NASA Astrophysics Data System (ADS)

    Petryk, Alicia A.; Misra, Adwiteeya; Kastner, Elliot J.; Mazur, Courtney M.; Petryk, James D.; Hoopes, P. Jack

    2015-03-01

    The use of hyperthermia to treat cancer is well studied and has utilized numerous delivery techniques, including microwaves, radio frequency, focused ultrasound, induction heating, infrared radiation, warmed perfusion liquids (combined with chemotherapy), and recently, metallic nanoparticles (NP) activated by near infrared radiation (NIR) and alternating magnetic field (AMF) based platforms. It has been demonstrated by many research groups that ablative temperatures and cytotoxicity can be produced with locally NP-based hyperthermia. Such ablative NP techniques have demonstrated the potential for success. Much attention has also been given to the fact that NP may be administered systemically, resulting in a broader cancer therapy approach, a lower level of tumor NP content and a different type of NP cancer therapy (most likely in the adjuvant setting). To use NP based hyperthermia successfully as a cancer treatment, the technique and its goal must be understood and utilized in the appropriate clinical context. The parameters include, but are not limited to, NP access to the tumor (large vs. small quantity), cancer cell-specific targeting, drug carrying capacity, potential as an ionizing radiation sensitizer, and the material properties (magnetic characteristics, size and charge). In addition to their potential for cytotoxicity, the material properties of the NP must also be optimized for imaging, detection and direction. In this paper we will discuss the differences between, and potential applications for, ablative and non-ablative magnetic nanoparticle hyperthermia.

  9. Laser ablation of phenylazide in an argon matrix: direct observation and chemical reactivity of ablated fragments

    NASA Astrophysics Data System (ADS)

    Niino, H.; Sato, T.; Yabe, A.

    Ablation of pentafluorophenylazide (FPA) in an Ar matrix at 8-10 K was carried out upon irradiation with ns-pulsed UV lasers in a vacuum. The plume of ablated products was monitored by a time-resolved imaging/spectroscopic technique using a gated and intensified CCD camera system. A large amount of pentafluorophenylnitrene (FPN) having a high kinetic energy ( 6 eV) was ejected as fragments from the matrix film during ablation. A quantitative formation of triplet FPN from the photolysis of the FPA was observed by spectroscopic measurements in the IR and UV-visible regions, and was confirmed by a theoretical IR spectrum calculated according to density functional theory. A FPN beam is useful for chemical surface modification of organic materials, such as aromatic polyester and alkylthiol. A surface analysis of these materials by X-ray photoelectron spectroscopy and Fourier transform infrared reflection absorption spectroscopy showed that the FPN was immobilized onto the surface through chemical bonds. This technique for the chemical surface modification of materials is made possible by a pulsed beam of reactive fragments with a high density in the laser ablation process.

  10. Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds

    NASA Technical Reports Server (NTRS)

    Esper, Jaime; Lengowski, Michael

    2012-01-01

    Ablative materials are required to protect a space vehicle from the extreme temperatures encountered during the most demanding (hyperbolic) atmospheric entry velocities, either for probes launched toward other celestial bodies, or coming back to Earth from deep space missions. To that effect, the resin-impregnated carbon ablator (RICA) is a high-temperature carbon/phenolic ablative thermal protection system (TPS) material designed to use modern and commercially viable components in its manufacture. Heritage carbon/phenolic ablators intended for this use rely on materials that are no longer in production (i.e., Galileo, Pioneer Venus); hence the development of alternatives such as RICA is necessary for future NASA planetary entry and Earth re-entry missions. RICA s capabilities were initially measured in air for Earth re-entry applications, where it was exposed to a heat flux of 14 MW/sq m for 22 seconds. Methane tests were also carried out for potential application in Saturn s moon Titan, with a nominal heat flux of 1.4 MW/sq m for up to 478 seconds. Three slightly different material formulations were manufactured and subsequently tested at the Plasma Wind Tunnel of the University of Stuttgart in Germany (PWK1) in the summer and fall of 2010. The TPS integrity was well preserved in most cases, and results show great promise.

  11. Langmuir probe characterization of laser ablation plasmas

    SciTech Connect

    Doggett, Brendan; Lunney, James G.

    2009-02-01

    For laser ablation plumes that are significantly ionized, Langmuir probes have proved to be a useful tool for measuring the plume shape, ion energy distribution, and electron temperature. Typically in laser ablation plasmas the flow velocity is supersonic, which complicates the interpretation of the current-voltage probe characteristic. In this paper we describe some recent developments on the application of Langmuir probes for laser ablation plume diagnosis. We have investigated the behavior of the probe when it is orientated perpendicular, and parallel, to the plasma flow, and show how an analytical model developed for plasma immersion ion implantation, can quantitatively describe the variation of the ion current with probe bias for the case when the plasma flow is along the probe surface. The ion signal recorded by a probe in the parallel position is proportional to the ion density and the square root of the bias voltage. It is shown that the current varies as m{sub i}{sup -1/2} so that by comparing the ion signals from the parallel and perpendicular positions it is possible to estimate the mass of the ions detected. We have also determined the temporal variation of electron temperature. A planar probe oriented parallel to the plasma flow, where the ion current due to the plasma flow is eliminated, gives a more reliable measurement of T{sub e} (<0.6 eV). The measured T{sub e} is consistent with the measured ion current, which is dependent on T{sub e} when the time taken for an element of plasma to traverse the probe is longer than the time taken for the matrix ion sheath extraction phase.

  12. Dynamical modeling of laser ablation processes

    SciTech Connect

    Leboeuf, J.N.; Chen, K.R.; Donato, J.M.; Geohegan, D.B.; Liu, C.L.; Puretzky, A.A.; Wood, R.F.

    1995-09-01

    Several physics and computational approaches have been developed to globally characterize phenomena important for film growth by pulsed laser deposition of materials. These include thermal models of laser-solid target interactions that initiate the vapor plume; plume ionization and heating through laser absorption beyond local thermodynamic equilibrium mechanisms; gas dynamic, hydrodynamic, and collisional descriptions of plume transport; and molecular dynamics models of the interaction of plume particles with the deposition substrate. The complexity of the phenomena involved in the laser ablation process is matched by the diversity of the modeling task, which combines materials science, atomic physics, and plasma physics.

  13. Dopant Distribution in NIF Beryllium Ablator Capsules

    NASA Astrophysics Data System (ADS)

    Huang, H.; Xu, H. W.; Youngblood, K. P.; Wall, D. R.; Stephens, R. B.; Moreno, K. A.; Nikroo, A.; Salmonson, J. D.; Haan, S. W.; Wu, K. J.; Wang, Y. M.; Hamza, A. V.

    2012-10-01

    Good implosion performance requires capsule ablator material with spherically uniform x-ray opacity, which is controlled by one of several dopants (Cu, Si, Al, etc.) in the Be shell. During production, the dopant concentration is radially stepped. However, the various Be-dopant interactions result in vastly different dopant distribution patterns, some quite inhomogeneous. We have characterized these structures and established the phenomenological basis and the magnitudes of the inhomogeneity both in spatial length scales and in atomic percent. We will discuss the case of inhomogeneous Cu diffusion in detail, followed by discussions of other dopants and the estimate of the impact of these structures on target implosion.

  14. Ultrafast femtosecond laser ablation of graphite

    NASA Astrophysics Data System (ADS)

    Ionin, Andrey A.; Kudryashov, Sergey I.; Makarov, Sergey V.; Mel'nik, N. N.; Saltuganov, Pavel N.; Seleznev, Leonid V.; Sinitsyn, Dmitry V.

    2015-06-01

    Fluence dependences of IR and UV reflectivity of femtosecond laser pulses on a HOPG surface demonstrate their saturation in a certain fluence range, starting from 0.2 J cm-2, where single-shot non-linear plasma emission is detected by electric probe measurements. This correlation between prompt solid-state optical/electronic dynamics and electron-ion plasma emission indicates prompt ‘freezing’ of surface electronic dynamics via its plasma-emission cooling and simultaneous ultrafast shallow laser ablation of the surface. Strong HOPG disordering is observed in Raman spectra for laser fluences, exceeding the plasma emission threshold.

  15. Solar cell contact formation using laser ablation

    DOEpatents

    Harley, Gabriel; Smith, David D.; Cousins, Peter John

    2015-07-21

    The formation of solar cell contacts using a laser is described. A method of fabricating a back-contact solar cell includes forming a poly-crystalline material layer above a single-crystalline substrate. The method also includes forming a dielectric material stack above the poly-crystalline material layer. The method also includes forming, by laser ablation, a plurality of contacts holes in the dielectric material stack, each of the contact holes exposing a portion of the poly-crystalline material layer; and forming conductive contacts in the plurality of contact holes.

  16. Solar cell contact formation using laser ablation

    DOEpatents

    Harley, Gabriel; Smith, David; Cousins, Peter

    2012-12-04

    The formation of solar cell contacts using a laser is described. A method of fabricating a back-contact solar cell includes forming a poly-crystalline material layer above a single-crystalline substrate. The method also includes forming a dielectric material stack above the poly-crystalline material layer. The method also includes forming, by laser ablation, a plurality of contacts holes in the dielectric material stack, each of the contact holes exposing a portion of the poly-crystalline material layer; and forming conductive contacts in the plurality of contact holes.

  17. Solar cell contact formation using laser ablation

    DOEpatents

    Harley, Gabriel; Smith, David D.; Cousins, Peter John

    2014-07-22

    The formation of solar cell contacts using a laser is described. A method of fabricating a back-contact solar cell includes forming a poly-crystalline material layer above a single-crystalline substrate. The method also includes forming a dielectric material stack above the poly-crystalline material layer. The method also includes forming, by laser ablation, a plurality of contacts holes in the dielectric material stack, each of the contact holes exposing a portion of the poly-crystalline materiat layer; and forming conductive contacts in the plurality of contact holes.

  18. Radiofrequency ablation for benign thyroid nodules.

    PubMed

    Bernardi, S; Stacul, F; Zecchin, M; Dobrinja, C; Zanconati, F; Fabris, B

    2016-09-01

    Benign thyroid nodules are an extremely common occurrence. Radiofrequency ablation (RFA) is gaining ground as an effective technique for their treatment, in case they become symptomatic. Here we review what are the current indications to RFA, its outcomes in terms of efficacy, tolerability, and cost, and also how it compares to the other conventional and experimental treatment modalities for benign thyroid nodules. Moreover, we will also address the issue of treating with this technique patients with cardiac pacemakers (PM) or implantable cardioverter-defibrillators (ICD), as it is a rather frequent occurrence that has never been addressed in detail in the literature.

  19. Sprayable low density ablator and application process

    NASA Technical Reports Server (NTRS)

    Sharpe, M. H.; Hill, W. E.; Simpson, W. G.; Carter, J. M.; Brown, E. L.; King, H. M.; Schuerer, P. H.; Webb, D. D. (Inventor)

    1978-01-01

    A sprayable, low density ablative composition is described consisting esentially of: (1) 100 parts by weight of a mixture of 25-65% by weight of phenolic microballoons, 0-20% by weight of glass microballoons, 4-10% by weight of glass fibers, 25-45% by weight of an epoxy-modified polyurethane resin, 2-4% by weight of a bentonite dispersing aid, and 1-2% by weight of an alcohol activator for the bentonite; (2) 1-10 parts by weight of an aromatic amine curing agent; and (3) 200-400 parts by weight of a solvent.

  20. Critical gravity in four dimensions.

    PubMed

    Lü, H; Pope, C N

    2011-05-01

    We study four-dimensional gravity theories that are rendered renormalizable by the inclusion of curvature-squared terms to the usual Einstein action with a cosmological constant. By choosing the parameters appropriately, the massive scalar mode can be eliminated and the massive spin-2 mode can become massless. This "critical" theory may be viewed as a four-dimensional analogue of chiral topologically massive gravity, or of critical "new massive gravity" with a cosmological constant, in three dimensions. We find that the on-shell energy for the remaining massless gravitons vanishes. There are also logarithmic spin-2 modes, which have positive energy. The mass and entropy of standard Schwarzschild-type black holes vanish. The critical theory might provide a consistent toy model for quantum gravity in four dimensions. PMID:21635082

  1. Critical Gravity in Four Dimensions

    SciTech Connect

    Lue, H.; Pope, C. N.

    2011-05-06

    We study four-dimensional gravity theories that are rendered renormalizable by the inclusion of curvature-squared terms to the usual Einstein action with a cosmological constant. By choosing the parameters appropriately, the massive scalar mode can be eliminated and the massive spin-2 mode can become massless. This ''critical'' theory may be viewed as a four-dimensional analogue of chiral topologically massive gravity, or of critical 'new massive gravity' with a cosmological constant, in three dimensions. We find that the on-shell energy for the remaining massless gravitons vanishes. There are also logarithmic spin-2 modes, which have positive energy. The mass and entropy of standard Schwarzschild-type black holes vanish. The critical theory might provide a consistent toy model for quantum gravity in four dimensions.

  2. Critical gravity in four dimensions.

    PubMed

    Lü, H; Pope, C N

    2011-05-01

    We study four-dimensional gravity theories that are rendered renormalizable by the inclusion of curvature-squared terms to the usual Einstein action with a cosmological constant. By choosing the parameters appropriately, the massive scalar mode can be eliminated and the massive spin-2 mode can become massless. This "critical" theory may be viewed as a four-dimensional analogue of chiral topologically massive gravity, or of critical "new massive gravity" with a cosmological constant, in three dimensions. We find that the on-shell energy for the remaining massless gravitons vanishes. There are also logarithmic spin-2 modes, which have positive energy. The mass and entropy of standard Schwarzschild-type black holes vanish. The critical theory might provide a consistent toy model for quantum gravity in four dimensions.

  3. Double Semions in Arbitrary Dimension

    NASA Astrophysics Data System (ADS)

    Freedman, Michael H.; Hastings, Matthew B.

    2016-10-01

    We present a generalization of the double semion topological quantum field theory to higher dimensions, as a theory of {d-1} dimensional surfaces in a d dimensional ambient space. We construct a local Hamiltonian that is a sum of commuting projectors and analyze the excitations and the ground state degeneracy. Defining a consistent set of local rules requires the sign structure of the ground state wavefunction to depend not just on the number of disconnected surfaces, but also upon their higher Betti numbers through the semicharacteristic. For odd d the theory is related to the toric code by a local unitary transformation, but for even d the dimension of the space of zero energy ground states is in general different from the toric code and for even {d > 2} it is also in general different from that of the twisted {Z_2} Dijkgraaf-Witten model.

  4. Turing patterns in three dimensions

    NASA Astrophysics Data System (ADS)

    Shoji, Hiroto; Yamada, Kohtaro; Ueyama, Daishin; Ohta, Takao

    2007-04-01

    We investigate three-dimensional Turing patterns in two-component reaction diffusion systems. The FitzHugh-Nagumo equation, the Brusselator, and the Gray-Scott model are solved numerically in three dimensions. Several interconnected structures of domains as well as lamellar, hexagonal, and spherical domains are obtained as stable motionless equilibrium patterns. The relative stability of these structures is studied analytically based on the reduction approximation. The relation with the microphase-separated structures in block copolymers is also discussed.

  5. BMS modules in three dimensions

    NASA Astrophysics Data System (ADS)

    Campoleoni, A.; Gonzalez, H. A.; Oblak, B.; Riegler, M.

    2016-04-01

    We build unitary representations of the BMS algebra and its higher-spin extensions in three dimensions, using induced representations as a guide. Our prescription naturally emerges from an ultrarelativistic limit of highest-weight representations of Virasoro and 𝒲 algebras, which is to be contrasted with nonrelativistic limits that typically give nonunitary representations. To support this dichotomy, we also point out that the ultrarelativistic and nonrelativistic limits of generic 𝒲 algebras differ in the structure of their nonlinear terms.

  6. Supergravity Theory from Ten Dimensions.

    NASA Astrophysics Data System (ADS)

    Romans, Larry James

    1985-12-01

    This work is concerned with the study of several ten-dimensional field theories intimately associated with superstring theories, and possibilities for obtaining realistic four-dimensional theories from them. Three chapters follow the N = 2b supergravity from ten to five, then to four dimensions. First of all, compactifications to five dimensions on various manifolds are studied. Then the entire mass spectrum for the compactification on S('5) is derived using techniques of harmonic analysis on spheres. A particular set of modes corresponds to a gauged maximal supergravity theory in five dimensions; this theory, with Yang-Mills group SO(6), is constructed in detail. By a process similar to analytic continuation, noncompact versions of this theory are also obtained, gauging all the semisimple real forms of SO(6). One particular form, with gauge group SO*(6) (DBLTURN) SU(3,1), compactifies to flat four-dimensional spacetime and offers attractive phenomenological possibilities. The final chapter is concerned with candidates for effective low-energy theories for N = 1 superstrings with gauge group SO(32) or E(,8) x E(,8). These effective theories contain curvature squared terms, and require unusual gravitational interactions to cancel anomalies. The field equations are derived and found to admit compactifications to flat four dimensional spacetime, with the possibility of accommodating many phenomenological considerations.

  7. Infrared laser ablation of dental enamel: influence of an applied water layer on ablation rate and peripheral damage

    NASA Astrophysics Data System (ADS)

    Ashouri, Nahal; Shori, Ramesh K.; Cheung, Jason M.; Fried, Daniel

    2001-04-01

    Studies have shown that a water spray may augment the laser ablation rate of dental hard tissues in addition to reducing heat accumulation. However, the mechanism of augmentation is controversial and poorly understood. The influence of an optically thick applied water layer on the ablation rate was investigated at wavelengths in which water is a primary absorber and the magnitude of absorption varies markedly. Water was manually applied with a pipette and troughs were cut in enamel blocks using a laser scanning system. Q- switched and free running Er:YSGG and Er:YAG, free running Ho:YAG and 9.6 micrometers TEA CO2 laser systems were investigated. The addition of water increased the rate of ablation and produced a more desirable surface morphology during enamel ablation with all the erbium systems. Ablation was markedly more efficient for the Q-switched erbium lasers than for the longer free-running laser systems when a water layer was added. Although, the addition of a thick water layer reduced the rate of ablation during CO2 laser ablation, the addition of the water removed undesirable deposits of non-apatite mineral phases from the crater surface. There was extensive peripheral damage after irradiation with the Ho:YAG laser with and without added water without effective ablation of enamel. The results of this study suggest that water augments the ablation of dental enamel by aiding in the removal of loosely attached deposits of non-apatite mineral phase from the crater surface, thus producing a more desirable crater surface morphology. The non-apatite mineral phase interfere with subsequent laser pulses during erbium laser irradiation reducing the rate of ablation and their removal aids in maintaining efficient ablation during multiple pulses irradiation.

  8. Targeted ablation and reorganization of the principal preplate neurons and their neuroblasts identified by golli promoter transgene expression in the neocortex of mice

    PubMed Central

    Xie, Yuan-Yun; Jacobs, Erin; Fisher, Robin

    2009-01-01

    The present study delineates the cellular responses of dorsal pallium to targeted genetic ablation of the principal preplate neurons of the neocortex. Ganciclovir treatment during prenatal development (E11–E13; where E is embryonic day) of mice selectively killed cells with shared S-phase vulnerability and targeted expression of a GPT [golli promoter transgene, linked to HSV-TK (herpes simplex virus-thymidine kinase), τ-eGFP (τ-enhanced green fluorescent protein) and lacZ (lacZ galactosidase) reporters] localized in preplate neurons. Morphogenetic fates of attacked neurons and neuroblasts, and their successors, were assessed by multiple labelling in time-series comparisons between ablated (HSV-TK+/0) and control (HSV-TK0/0) littermates. During ablation generation, neocortical growth was suppressed, and compensatory reorganization of non-GPT ventricular zone progenitors of dorsal pallium produced replacements for killed GPT neuroblasts. Replacement and surviving GPT neuroblasts then produced replacements for killed GPT neurons. Near-normal restoration of their complement delayed the settlement of GPT neurons into the reconstituted preplate, which curtailed the outgrowth of pioneer corticofugal axons. Based on this evidence, we conclude that specific cell killing in ablated mice can eliminate a major fraction of GPT neurons, with insignificant bystander killing. Also, replacement GPT neurons in ablated mice originate exclusively by proliferation from intermediate progenitor GPT neuroblasts, whose complement is maintained by non-GPT progenitors for inductive regulation of the total complement of GPT neurons. Finally, GPT neurons in both normal and ablated mice meet all morphogenetic criteria, including the ‘outside-in’ vertical gradient of settlement, presently used to identify principal preplate neurons. In ablated mice, delayed organization of these neurons desynchronizes and isolates developing neocortex from the rest of the brain, and permanently impairs

  9. Trowelable ablative coating composition and method of use

    NASA Technical Reports Server (NTRS)

    Headrick, Stephen E. (Inventor); Hill, Roger L. (Inventor)

    1989-01-01

    A trowelable ablative coating composition is disclosed. The composition comprises an epoxy resin, an amide curing agent, glass microspheres and ground cork. A method for protecting a substrate is also disclosed. The method comprises applying the trowelable ablative coating discussed above to a substrate and curing the coating composition.

  10. Trowelable ablative coating composition and method of use

    NASA Technical Reports Server (NTRS)

    Headrick, Stephen E. (Inventor); Hill, Roger L. (Inventor)

    1988-01-01

    A trowelable ablative coating composition is disclosed. The composition comprises an epoxy resin, an amide curing agent, glass microspheres and ground cork. A method for protecting a substrate is also disclosed. The method comprises applying the trowelable ablative coating discussed above to a substrate and curing the coating composition.

  11. Rail gun performance and plasma characteristics due to wall ablation

    NASA Technical Reports Server (NTRS)

    Ray, P. K.

    1986-01-01

    The experiment of Bauer, et al. (1982) is analyzed by considering wall ablation and viscous drag in the plasma. Plasma characteristics are evaluated through a simple fluid-mechanical analysis considering only wall ablation. By equating the energy dissipated in the plasma with the radiation heat loss, the average properties of the plasma are determined as a function of time.

  12. Variations in Alaska tidewater glacier frontal ablation, 1985-2013

    NASA Astrophysics Data System (ADS)

    McNabb, R. W.; Hock, R.; Huss, M.

    2015-01-01

    Our incomplete knowledge of the proportion of mass loss due to frontal ablation (the sum of ice loss through calving and submarine melt) from tidewater glaciers outside of the Greenland and Antarctic ice sheets has been cited as a major hindrance to accurate predictions of global sea level rise. We present a 28 year record (1985-2013) of frontal ablation for 27 Alaska tidewater glaciers (representing 96% of the total tidewater glacier area in the region), calculated from satellite-derived ice velocities and modeled estimates of glacier ice thickness. We account for cross-sectional ice thickness variation, long-term thickness changes, mass lost between an upstream fluxgate and the terminus, and mass change due to changes in terminus position. The total mean rate of frontal ablation for these 27 glaciers over the period 1985-2013 is 15.11 ± 3.63Gta-1. Two glaciers, Hubbard and Columbia, account for approximately 50% of these losses. The regional total ablation has decreased at a rate of 0.14Gta-1 over this time period, likely due to the slowing and thinning of many of the glaciers in the study area. Frontal ablation constitutes only ˜4% of the total annual regional ablation, but roughly 20% of net mass loss. Comparing several commonly used approximations in the calculation of frontal ablation, we find that neglecting cross-sectional thickness variations severely underestimates frontal ablation.

  13. Ablation dynamics in coiled wire-array Z-pinches

    SciTech Connect

    Hall, G. N.; Lebedev, S. V.; Suzuki-Vidal, F.; Swadling, G.; Chittenden, J. P.; Bland, S. N.; Harvey-Thompson, A.; Knapp, P. F.; Blesener, I. C.; McBride, R. D.; Chalenski, D. A.; Blesener, K. S.; Greenly, J. B.; Pikuz, S. A.; Shelkovenko, T. A.; Hammer, D. A.; Kusse, B. R.

    2013-02-15

    Experiments to study the ablation dynamics of coiled wire arrays were performed on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and on the COBRA generator at Cornell University's Laboratory of Plasma Studies (1 MA, 100 ns). The MAGPIE generator was used to drive coiled wires in an inverse array configuration to study the distribution of ablated plasma. Using interferometry to study the plasma distribution during the ablation phase, absolute quantitative measurements of electron line density demonstrated very high density contrasts between coiled ablation streams and inter-stream regions many millimetres from the wire. The measured density contrasts for a coiled array were many times greater than that observed for a conventional array with straight wires, indicating that a much greater axial modulation of the ablated plasma may be responsible for the unique implosion dynamics of coiled arrays. Experiments on the COBRA generator were used to study the complex redirection of plasma around a coiled wire that gives rise to the ablation structure exhibited by coiled arrays. Observations of this complex 3D plasma structure were used to validate the current model of coiled array ablation dynamics [Hall et al., Phys. Rev. Lett. 100, 065003 (2008)], demonstrating irrefutably that plasma flow from the wires behaves as predicted. Coiled wires were observed to ablate and implode in the same manner on both machines, indicating that current rise time should not be an issue for the scaling of coiled arrays to larger machines with fast current rise times.

  14. Ablation of crystalline oxides by infrared femtosecond laser pulses

    SciTech Connect

    Watanabe, Fumiya; Cahill, David G.; Gundrum, Bryan; Averback, R. S.

    2006-10-15

    We use focused laser pulses with duration of 180 fs and wavelength of 800 nm to study the interactions of high power near-infrared light with the surfaces of single-crystal transparent oxides (sapphire, LaAlO{sub 3}, SrTiO{sub 3}, yttria-stabilized ZrO{sub 2}, and MgO); the morphologies of the ablation craters are studied by atomic force microscopy and scanning electron microscopy. With the exception of LaAlO{sub 3}, the high temperature annealing of these oxide crystals produces atomically flat starting surfaces that enable studies of the morphology of ablation craters with subnanometer precision. The threshold fluence for ablation is determined directly from atomic-force microscopy images and increases approximately linearly with the band gap of the oxide. For all oxides except sapphire, the depth of the ablation crater increases approximately as the square root of the difference between the peak laser fluence and the threshold fluence for ablation. Sapphire shows unique behavior: (i) at laser fluences within 1 J/cm{sup 2} of the threshold for ablation, the depth of the ablation crater increases gradually instead of abruptly with laser fluence, and (ii) the rms roughness of the ablation crater shows a pronounced minimum of <0.2 nm at a laser fluence of 1 J/cm{sup 2} above the threshold.

  15. In vivo thermal ablation monitoring using ultrasound echo decorrelation imaging.

    PubMed

    Subramanian, Swetha; Rudich, Steven M; Alqadah, Amel; Karunakaran, Chandra Priya; Rao, Marepalli B; Mast, T Douglas

    2014-01-01

    Previous work indicated that ultrasound echo decorrelation imaging can track and quantify changes in echo signals to predict thermal damage during in vitro radiofrequency ablation (RFA). In the in vivo studies reported here, the feasibility of using echo decorrelation imaging as a treatment monitoring tool was assessed. RFA was performed on normal swine liver (N = 5), and ultrasound ablation using image-ablate arrays was performed on rabbit liver implanted with VX2 tumors (N = 2). Echo decorrelation and integrated backscatter were computed from Hilbert transformed pulse-echo data acquired during RFA and ultrasound ablation treatments. Receiver operating characteristic (ROC) curves were employed to assess the ability of echo decorrelation imaging and integrated backscatter to predict ablation. Area under the ROC curves (AUROC) was determined for RFA and ultrasound ablation using echo decorrelation imaging. Ablation was predicted more accurately using echo decorrelation imaging (AUROC = 0.832 and 0.776 for RFA and ultrasound ablation, respectively) than using integrated backscatter (AUROC = 0.734 and 0.494). PMID:24239361

  16. A New Ablative Heat Shield Sensor Suite Project

    NASA Technical Reports Server (NTRS)

    Bose, Deepak

    2014-01-01

    A new sensor suite is developed to measure performance of ablative thermal protection systems used in planetary entry vehicles for robotic and human exploration. The new sensor suite measures ablation of the thermal protection system under extreme heating encountered during planetary entry. The sensor technology is compatible with a variety of thermal protection materials, and is applicable over a wide range of entry conditions.

  17. Laser ablation of paper: Raman identification of products

    NASA Astrophysics Data System (ADS)

    Balakhnina, Irina; Brandt, Nikolay; Chikishev, Andrey; Rebrikova, Natalia; Yurchuk, Yuliya

    2014-12-01

    Old paper samples are bleached using pulsed laser radiation with a wavelength of 532 nm. The ablation products of five paper samples that differ by composition and production dates are studied using Raman microspectroscopy. Cellulose, protein, calcite, titanium dioxide (anatase, rutile, and brookite), quartz, lazurite, bonattite, and dolomite are identified as ablation products.

  18. Ultrafast laser ablation for targeted atherosclerotic plaque removal

    NASA Astrophysics Data System (ADS)

    Lanvin, Thomas; Conkey, Donald B.; Descloux, Laurent; Frobert, Aurelien; Valentin, Jeremy; Goy, Jean-Jacques; Cook, Stéphane; Giraud, Marie-Noelle; Psaltis, Demetri

    2015-07-01

    Coronary artery disease, the main cause of heart disease, develops as immune cells and lipids accumulate into plaques within the coronary arterial wall. As a plaque grows, the tissue layer (fibrous cap) separating it from the blood flow becomes thinner and increasingly susceptible to rupturing and causing a potentially lethal thrombosis. The stabilization and/or treatment of atherosclerotic plaque is required to prevent rupturing and remains an unsolved medical problem. Here we show for the first time targeted, subsurface ablation of atherosclerotic plaque using ultrafast laser pulses. Excised atherosclerotic mouse aortas were ablated with ultrafast near-infrared (NIR) laser pulses. The physical damage was characterized with histological sections of the ablated atherosclerotic arteries from six different mice. The ultrafast ablation system was integrated with optical coherence tomography (OCT) imaging for plaque-specific targeting and monitoring of the resulting ablation volume. We find that ultrafast ablation of plaque just below the surface is possible without causing damage to the fibrous cap, which indicates the potential use of ultrafast ablation for subsurface atherosclerotic plaque removal. We further demonstrate ex vivo subsurface ablation of a plaque volume through a catheter device with the high-energy ultrafast pulse delivered via hollow-core photonic crystal fiber.

  19. Laser ablation synthesis and spectral characterization of ruby nanoparticles

    NASA Astrophysics Data System (ADS)

    Baranov, M. S.; Bardina, A. A.; Savelyev, A. G.; Khramov, V. N.; Khaydukov, E. V.

    2016-04-01

    The laser ablation method was implemented for synthesis of ruby nanoparticles. Nanoparticles were obtained by nanosecond ablation of bulk ruby crystal in 10% ethanol water solution. The nanoparticles enable water colloid stability and exhibit narrow photoluminescent line at 694 nm when pumped at blue-green spectral range. The ruby nanoparticles were characterized by SEM and Z-sizer.

  20. Scanning photorefractive keratectomy at 213 nm: PMMA ablations

    NASA Astrophysics Data System (ADS)

    Manns, Fabrice; Rol, Pascal O.; Wosnitza, Martin; Maine, Patrick; Parel, Jean-Marie A.

    1999-06-01

    Purpose: In scanning photorefractive keratectomy, the corneal surface is reshaped by laser ablation with a scanning beam for the correction of myopia or astigmatism. A precise knowledge of the volume of corneal tissue removed by each laser pulse is necessary to be able to develop accurate ablation algorithms for scanning photorefractive keratectomy. The purpose of this study was to measure the ablation per pulse created on PMMA surfaces with a Q-switched frequency-quintupled Nd:YAG laser emitting at 213 nm. Methods: A frequency-quintupled Nd:YAG laser emitting at 213 nm with a pulse duration of 5 ns and a pulse energy of 1.2 to 1.5 mJ was used. The laser beam was focused on the surface of PMMA blocks and ablation craters were produced with 10, 50 and 100 pulses. The shape of the ablation craters was measured with an optical profilometer and compared with the beam profile measured with a laser beam diagnostic system. Results: The beam intensity distribution in the near-field consisted of two quasi-Gaussian peaks. The ablation craters contained two peaks. Assuming a Gaussian intensity distribution, the ablation per pulse in PMMA at 213 nm can be modeled by a parabolic function. Conclusions: Optical profilometry can be used to accurately measure the ablation per pulse and evaluate the homogeneity of the beam.

  1. A Theoretical Study of Stagnation-Point Ablation

    NASA Technical Reports Server (NTRS)

    Roberts, Leonard

    1959-01-01

    A simplified analysis is made of ablation cooling near the stagnation point of a two-dimensional or axisymmetric body which occurs as the body vaporizes directly from the solid state. The automatic shielding mechanism Is discussed and the important thermal properties required by a good ablation material are given. The results of the analysis are given in terms of dimensionless parameters.

  2. Percutaneous Image-Guided Ablation of Breast Tumors: An Overview

    PubMed Central

    Sag, Alan A.; Maybody, Majid; Comstock, Christopher; Solomon, Stephen B.

    2014-01-01

    Percutaneous non-surgical image-guided ablation is emerging as an adjunct or alternative to surgery in the management of benign and malignant breast tumors. This review covers the current state of the literature regarding percutaneous image-guided ablation modalities, clinical factors regarding patient selection, and future directions for research. PMID:25049447

  3. Rare event molecular dynamics simulations of plasma induced surface ablation

    SciTech Connect

    Sharia, Onise; Holzgrafe, Jeffrey; Park, Nayoung; Henkelman, Graeme

    2014-08-21

    The interaction of thermal Ar plasma particles with Si and W surfaces is modeled using classical molecular dynamics (MD) simulations. At plasma energies above the threshold for ablation, the ablation yield can be calculated directly from MD. For plasma energies below threshold, the ablation yield becomes exponentially low, and direct MD simulations are inefficient. Instead, we propose an integration method where the yield is calculated as a function of the Ar incident kinetic energy. Subsequent integration with a Boltzmann distribution at the temperature of interest gives the thermal ablation yield. At low plasma temperatures, the ablation yield follows an Arrhenius form in which the activation energy is shown to be the threshold energy for ablation. Interestingly, equilibrium material properties, including the surface and bulk cohesive energy, are not good predictors of the threshold energy for ablation. The surface vacancy formation energy is better, but is still not a quantitative predictor. An analysis of the trajectories near threshold shows that ablation occurs by different mechanisms on different material surfaces, and both the mechanism and the binding of surface atoms determine the threshold energy.

  4. Rare event molecular dynamics simulations of plasma induced surface ablation.

    PubMed

    Sharia, Onise; Holzgrafe, Jeffrey; Park, Nayoung; Henkelman, Graeme

    2014-08-21

    The interaction of thermal Ar plasma particles with Si and W surfaces is modeled using classical molecular dynamics (MD) simulations. At plasma energies above the threshold for ablation, the ablation yield can be calculated directly from MD. For plasma energies below threshold, the ablation yield becomes exponentially low, and direct MD simulations are inefficient. Instead, we propose an integration method where the yield is calculated as a function of the Ar incident kinetic energy. Subsequent integration with a Boltzmann distribution at the temperature of interest gives the thermal ablation yield. At low plasma temperatures, the ablation yield follows an Arrhenius form in which the activation energy is shown to be the threshold energy for ablation. Interestingly, equilibrium material properties, including the surface and bulk cohesive energy, are not good predictors of the threshold energy for ablation. The surface vacancy formation energy is better, but is still not a quantitative predictor. An analysis of the trajectories near threshold shows that ablation occurs by different mechanisms on different material surfaces, and both the mechanism and the binding of surface atoms determine the threshold energy. PMID:25149805

  5. Radiofrequency ablation of hepatic tumors: lessons learned from 3000 procedures.

    PubMed

    Rhim, Hyunchul; Lim, Hyo K; Kim, Young-sum; Choi, Dongil; Lee, Won Jae

    2008-10-01

    Radiofrequency ablation has been accepted as the most popular local ablative therapy for unresectable malignant hepatic tumors. For 9 years from April 1999, we performed 3000 radiofrequency ablation procedures for hepatic tumors in our institution. Our results on the safety (mortality, 0.15%/patient) and therapeutic efficacy (5-year survival rate, 58%) are similar to those of previous studies reported, supporting the growing evidence of a clear survival benefit, excellent results for local tumor control and improved quality of life. The most important lesson learned from our 3000 procedures is that the best planning, safe ablation and complete ablation are key factors for patient outcome. Furthermore, multimodality treatment is the best strategy for recurrent hepatocellular carcinoma encountered after any kind of first-line treatment.

  6. Computational modeling of ultra-short-pulse ablation of enamel

    SciTech Connect

    London, R.A.; Bailey, D.S.; Young, D.A.

    1996-02-29

    A computational model for the ablation of tooth enamel by ultra-short laser pulses is presented. The role of simulations using this model in designing and understanding laser drilling systems is discussed. Pulses of duration 300 sec and intensity greater than 10{sup 12} W/cm{sup 2} are considered. Laser absorption proceeds via multi-photon initiated plasma mechanism. The hydrodynamic response is calculated with a finite difference method, using an equation of state constructed from thermodynamic functions including electronic, ion motion, and chemical binding terms. Results for the ablation efficiency are presented. An analytic model describing the ablation threshold and ablation depth is presented. Thermal coupling to the remaining tissue and long-time thermal conduction are calculated. Simulation results are compared to experimental measurements of the ablation efficiency. Desired improvements in the model are presented.

  7. Ablation of CsI by XUV Capillary Discharge Laser

    NASA Astrophysics Data System (ADS)

    Pira, Peter; Zelinger, Zdenek; Burian, Tomas; Vysin, Ludek; Wild, Jan; Juha, Libor; Lancok, Jan; Nevrly, Vaclav

    2015-09-01

    XUV capillary discharge laser (CDL) is suitable source for ablation of ionic crystals as material which is difficult to ablate by conventional laser. Single crystal of CsI was irradiated by 2.5 ns pulses of a 46.9 nm radiation at 2 Hz. The CDL beam was focused by Sc/Si multilayer spherical mirror. Attenuation length of CsI for this wavelength is 38 nm. Ablation rate was calculated after irradiation of 10, 20, 30, 50 and 100 pulses. Depth of the craters was measured by optical profiler (white light interferometry). Ablation threshold was determined from craters after irradiation with the changing fluence and compared with modeling by XUV-ABLATOR.

  8. Dynamics of Laser Ablation in Superfluid ^4He

    NASA Astrophysics Data System (ADS)

    Buelna, X.; Popov, E.; Eloranta, J.

    2016-10-01

    Pulsed laser ablation of metal targets immersed in superfluid ^4He is visualized by time-resolved shadowgraph photography and the products are analyzed by post-experiment atomic force microscopy (AFM) measurements. The expansion dynamics of the gaseous ablation half-bubble on the target surface appears underdamped and follows the predicted behavior for the thermally induced bubble growth mechanism. An inherent instability of the ablation bubble appears near its maximum radius and no tightly focused cavity collapse or rebound events are observed. During the ablation bubble retreat phase, the presence of sharp edges in the target introduces flow patterns that lead to the creation of large classical vortex rings. Furthermore, on the nanometer scale, AFM data reveal that the metal nanoparticles created by laser ablation are trapped in spherical vortex tangles and quantized vortex rings present in the non-equilibrium liquid.

  9. Laser ablation of a turbid medium: Modeling and experimental results

    SciTech Connect

    Brygo, F.; Semerok, A.; Weulersse, J.-M.; Thro, P.-Y.; Oltra, R.

    2006-08-01

    Q-switched Nd:YAG laser ablation of a turbid medium (paint) is studied. The optical properties (absorption coefficient, scattering coefficient, and its anisotropy) of a paint are determined with a multiple scattering model (three-flux model), and from measurements of reflection-transmission of light through thin layers. The energy deposition profiles are calculated at wavelengths of 532 nm and 1.064 {mu}m. They are different from those described by a Lambert-Beer law. In particular, the energy deposition of the laser beam is not maximum on the surface but at some depth inside the medium. The ablated rate was measured for the two wavelengths and compared with the energy deposition profile predicted by the model. This allows us to understand the evolution of the ablated depth with the wavelength: the more the scattering coefficient is higher, the more the ablated depth and the threshold fluence of ablation decrease.

  10. Characterization of Acute and Subacute Radiofrequency Ablation Lesions with Non-enhanced Magnetic Resonance Imaging

    PubMed Central

    Dickfeld, Timm; Kato, Ritsushi; Zviman, Menekem; Nazarian, Saman; Dong, Jun; Ashikaga, Hiroshi; Lardo, Albert C.; Berger, Ronald D.; Calkins, Hugh; Halperin, Henry

    2007-01-01

    Background MRI has the potential to visualize radiofrequency ablations (RFA), which have become the preferred treatment strategy for many arrhythmias. However, MRI patterns after RFA have not been well investigated. Objective This study sought to define the characteristic appearance and the effect of time and energy on non-contrast-enhanced MR imaging of RFA. Methods Using a power-controlled, cooled tip ablation system, RFA (5W–50W for 45s) were created on the right ventricular epicardium in 10 mongrel dogs. T1- and T2-weighted MR images were obtained during a 12-hours follow-up and compared to gross anatomy and histopathology. Results Lesions were successfully visualized with T2- and T1-weighted images 30min to 12 hours after RFA. T2 images were more consistent and displayed a characteristic elliptical, high-signal core (Contrast-to-noise-ratio [CNR] =18.9 ± 8.4) with a surrounding 0.5 mm low-intensity rim, which corresponded on histopathology to the central tissue necrosis and the transition zone, respectively. T1 images showed a less remarked increase in signal intensity (CNR=9.6 ± 7.4) without surrounding rim. Lesion size and appearance were well defined and unchanged during the 12 hours follow-up (ANOVA). CNR was independent of applied RF energy and allowed accurate assessment of the RFA at all time points (r=0.87 and r=0.83 for T2/T1 images, respectively). Transmural lesions, interlesional gaps and intralesional pathology could be reliably predicted in >90%. Conclusion Non-contrast-enhanced MRI allows accurate assessment of RFA and its intra-lesional pathology during a 12h follow-up. This confirms a possible role for MRI in guiding and evaluating RF application during electrophysiological ablation procedures. CONDENSED ABSTRACT MRI can visualize heat-induced tissue damage and its associated histological changes such as interstitial edema or protein necrosis through changes in T1- and T2-relaxation parameters. This study demonstrates that the

  11. Arcjet Testing of Advanced Conformal Ablative TPS

    NASA Technical Reports Server (NTRS)

    Gasch, Matthew; Beck, Robin; Agrawal, Parul

    2014-01-01

    A conformable TPS over a rigid aeroshell has the potential to solve a number of challenges faced by traditional rigid TPS materials (such as tiled Phenolic Impregnated Carbon Ablator (PICA) system on MSL. The compliant (high strain to failure) nature of the conformable ablative materials will allow integration of the TPS with the underlying aeroshell structure much easier and enable monolithic-like configuration and larger segments (or parts) to be used. In May of 2013 the CA250 project executed an arcjet test series in the Ames IHF facility to evaluate a phenolic-based conformal system (named Conformal-PICA) over a range of test conditions from 40-400Wcm2. The test series consisted of four runs in the 13-inch diameter nozzle. Test models were based on SPRITE configuration (a 55-deg sphere cone), as it was able to provide a combination of required heat flux, pressure and shear within a single entry. The preliminary in-depth TC data acquired during that test series allowed a mid-fidelity thermal response model for conformal-PICA to be created while testing of seam models began to address TPS attachment and joining of multiple segments for future fabrication of large-scale aeroshells. Discussed in this paper are the results.

  12. Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience

    SciTech Connect

    Carrafiello, Gianpaolo Lagana, Domenico; Cotta, Elisa; Mangini, Monica; Fontana, Federico; Bandiera, Francesca; Fugazzola, Carlo

    2010-08-15

    The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two patients with larger tumors (5 and 5.8 cm in diameter). All patients tolerated the procedure, and there with no major complications. Only 1 patient developed post-RFA syndrome (pain, fever, malaise, and leukocytosis), which resolved with oral administration of acetaminophen. Percutaneous RFA is a safe and effective treatment for patients with hepatic tumors: It is ideally suited for those who are not eligible for surgery. Long-term follow-up data regarding local and systemic recurrence and survival are still needed.

  13. Conditional Lineage Ablation to Model Human Diseases

    NASA Astrophysics Data System (ADS)

    Lee, Paul; Morley, Gregory; Huang, Qian; Fischer, Avi; Seiler, Stephanie; Horner, James W.; Factor, Stephen; Vaidya, Dhananjay; Jalife, Jose; Fishman, Glenn I.

    1998-09-01

    Cell loss contributes to the pathogenesis of many inherited and acquired human diseases. We have developed a system to conditionally ablate cells of any lineage and developmental stage in the mouse by regulated expression of the diphtheria toxin A (DTA) gene by using tetracycline-responsive promoters. As an example of this approach, we targeted expression of DTA to the hearts of adult mice to model structural abnormalities commonly observed in human cardiomyopathies. Induction of DTA expression resulted in cell loss, fibrosis, and chamber dilatation. As in many human cardiomyopathies, transgenic mice developed spontaneous arrhythmias in vivo, and programmed electrical stimulation of isolated-perfused transgenic hearts demonstrated a strikingly high incidence of spontaneous and inducible ventricular tachycardia. Affected mice showed marked perturbations of cardiac gap junction channel expression and localization, including a subset with disorganized epicardial activation patterns as revealed by optical action potential mapping. These studies provide important insights into mechanisms of arrhythmogenesis and suggest that conditional lineage ablation may have wide applicability for studies of disease pathogenesis.

  14. Low cost fabrication of ablative heat shields

    NASA Technical Reports Server (NTRS)

    Cecka, A. M.; Schofield, W. C.

    1972-01-01

    A material and process study was performed using subscale panels in an attempt to reduce the cost of fabricating ablative heat shield panels. Although no improvements were made in the material formulation, a significant improvement was obtained in the processing methods compared to those employed in the previous work. The principal feature of the new method is the press filling and curing of the ablation material in a single step with the bonding and curing of the face sheet. This method was chosen to replace the hand troweling and autoclave curing procedure used previously. Double-curvature panels of the same size as the flat panels were fabricated to investigate fabrication problems. It was determined that the same materials and processes used for flat panels can be used to produce the curved panels. A design with severe curvatures consisting of radii of 24 x 48 inches was employed for evaluation. Ten low-density and ten high-density panels were fabricated. With the exception of difficulties related to short run non-optimum tooling, excellent panel filling and density uniformity were obtained.

  15. Picosecond laser ablation of porcine sclera

    NASA Astrophysics Data System (ADS)

    Góra, Wojciech S.; Harvey, Eleanor M.; Dhillon, Baljean; Parson, Simon H.; Maier, Robert R. J.; Hand, Duncan P.; Shephard, Jonathan D.

    2013-03-01

    Lasers have been shown to be successful in certain medical procedures and they have been identified as potentially making a major contribution to the development of minimally invasive procedures. However, the uptake is not as widespread and there is scope for many other applications where laser devices may offer a significant advantage in comparison to the traditional surgical tools. The purpose of this research is to assess the potential of using a picosecond laser for minimally invasive laser sclerostomy. Experiments were carried out on porcine scleral samples due to the comparable properties to human tissue. Samples were prepared with a 5mm diameter trephine and were stored in lactated Ringer's solution. After laser machining, the samples were fixed in 3% glutaraldehyde, then dried and investigated under SEM. The laser used in the experiments is an industrial picosecond TRUMPF TruMicro laser operating at a wavelength of 1030nm, pulse length of 6ps, repetition rate of 1 kHz and a focused spot diameter of 30μm. The laser beam was scanned across the samples with the use of a galvanometer scan head and various ablation patterns were investigated. Processing parameters (pulse energy, spot and line separation) which allow for the most efficient laser ablation of scleral tissue without introducing any collateral damage were investigated. The potential to create various shapes, such as linear incisions, square cavities and circular cavities was demonstrated.

  16. Estrogen sulfotransferase ablation sensitizes mice to sepsis

    PubMed Central

    Chai, Xiaojuan; Guo, Yan; Jiang, Mengxi; Hu, Bingfang; Li, Zhigang; Fan, Jie; Deng, Meihong; Billiar, Timothy R.; Kucera, Heidi; Gaikwad, Nilesh W.; Xu, Meishu; Lu, Peipei; Yan, Jiong; Fu, Haiyan; Liu, Youhua; Yu, Lushan; Huang, Min; Zeng, Su; Xie, Wen

    2015-01-01

    Sepsis is the host's deleterious systemic inflammatory response to microbial infections. Here we report an essential role for the estrogen sulfotransferase (EST or SULT1E1), a conjugating enzyme that sulfonates and deactivates estrogens, in sepsis response. Both the cecal ligation and puncture (CLP) and lipopolysacharide (LPS) models of sepsis induce the expression of EST and compromise the activity of estrogen, an anti-inflammatory hormone. Surprisingly, EST ablation sensitizes mice to sepsis-induced death. Mechanistically, EST ablation attenuates sepsis-induced inflammatory responses due to compromised estrogen deactivation, leading to increased sepsis lethality. In contrast, transgenic overexpression of EST promotes estrogen deactivation and sensitizes mice to CLP-induced inflammatory response. The induction of EST by sepsis is NF-κB dependent and EST is a NF-κB target gene. The reciprocal regulation of inflammation and EST may represent a yet to be explored mechanism of endocrine regulation of inflammation, which has an impact on the clinical outcome of sepsis. PMID:26259151

  17. Producing Uniform Lesion Pattern in HIFU Ablation

    NASA Astrophysics Data System (ADS)

    Zhou, Yufeng; Kargl, Steven G.; Hwang, Joo Ha

    2009-04-01

    High intensity focused ultrasound (HIFU) is emerging as a modality for treatment of solid tumors. The temperature at the focus can reach over 65° C denaturing cellular proteins resulting in coagulative necrosis. Typically, HIFU parameters are the same for each treated spot in most HIFU control systems. Because of thermal diffusion from nearby spots, the size of lesions will gradually become larger as the HIFU therapy progresses, which may cause insufficient treatment of initial spots, and over-treatment of later ones. It is found that the produced lesion pattern also depends on the scanning pathway. From the viewpoint of the physician creating uniform lesions and minimizing energy exposure are preferred in tumor ablation. An algorithm has been developed to adaptively determine the treatment parameters for every spot in a theoretical model in order to maintain similar lesion size throughout the HIFU therapy. In addition, the exposure energy needed using the traditional raster scanning is compared with those of two other scanning pathways, spiral scanning from the center to the outside and from the outside to the center. The theoretical prediction and proposed algorithm were further evaluated using transparent gel phantoms as a target. Digital images of the lesions were obtained, quantified, and then compared with each other. Altogether, dynamically changing treatment parameters can improve the efficacy and safety of HIFU ablation.

  18. Spectroscopic characterization of laser ablated silicon plasma

    NASA Astrophysics Data System (ADS)

    Shakeel, Hira; Mumtaz, M.; Shahzada, S.; Nadeem, A.; Haq, S. U.

    2014-06-01

    We report plasma parameters of laser ablated silicon plasma using the fundamental (1064 nm) and second harmonics (532 nm) of a Nd : YAG laser. The electron temperature and electron number density are evaluated using the Boltzmann plot method and Stark broadened line profile, respectively. The electron temperature and electron number density are deduced using the same laser irradiance 2-16 GW cm-2 for 1064 nm and 532 nm as 6350-7000 K and (3.42-4.44) × 1016 cm-3 and 6000-6400 K and (4.20-5.72) × 1016 cm-3, respectively. The spatial distribution of plasma parameters shows a decreasing trend of 8200-6300 K and (4.00-3.60) × 1016 cm-3 for 1064 nm and 6400-5500 K and (5.10-4.50) × 1016 cm-3 for 532 nm laser ablation. Furthermore, plasma parameters are also investigated at low pressure from 45 to 550 mbar, yielding the electron temperature as 4580-5535 K and electron number density as (1.51-2.12) × 1016 cm-3. The trend of the above-mentioned results is in good agreement with previous investigations. However, wavelength-dependent studies and the spatial evolution of plasma parameters have been reported for the first time.

  19. Ultrasound catheters for circumferential cardiac ablation

    NASA Astrophysics Data System (ADS)

    Diederich, Chris J.; Nau, William H.; Taylor, Kevin; Maguire, Mark T.; Picazo, Guillermo; Gangu, Madhuri; Lesh, Michael D.

    1999-05-01

    The purpose of this study was to investigate performance characteristics of a catheter-based ultrasound applicator intended for circumferential ablation of cardiac tissue. The catheter design integrates a cylindrical ultrasound transducer within a distendable water filled balloon in order to produce circumferential lesions at sites in the atria (i.e., pulmonary vein ostia), intended for treatment of certain atrial arrhythmias. Biothermal simulations were used to investigate thermal lesion depths corresponding to variations in applied power, duration, balloon diameter, and acoustic efficiency. Prototype applicators of varying frequency (7 - 12 MHz) and balloon diameter were constructed and characterized using measurements of acoustic efficiency and rotational beam plots. In vitro studies were performed in freshly excised beef hearts to characterize the radial penetration, axial length, and angular uniformity of thermal lesions produced by these applicators. Selected applicators were tested in vivo within pulmonary veins, coronary sinus, and atrial appendage of canine and porcine hearts. These preliminary efforts have indicated that circumferential ablation of cardiac tissue using ultrasound balloon catheters is feasible, and devices between 7 - 12 MHz with balloon diameters of 1.5 - 2.0 cm are capable of producing uniform lesions between 1 - 5 mm depth or greater for treatment durations of 120 seconds or less.

  20. Margin Size is an Independent Predictor of Local Tumor Progression After Ablation of Colon Cancer Liver Metastases

    SciTech Connect

    Wang Xiaodong; Sofocleous, Constantinos T. Erinjeri, Joseph P.; Petre, Elena N.; Gonen, Mithat; Do, Kinh G.; Brown, Karen T.; Covey, Anne M.; Brody, Lynn A.; Alago, William; Thornton, Raymond H.; Kemeny, Nancy E.; Solomon, Stephen B.

    2013-02-15

    This study was designed to evaluate the relationship between the minimal margin size and local tumor progression (LTP) following CT-guided radiofrequency ablation (RFA) of colorectal cancer liver metastases (CLM). An institutional review board-approved, HIPPA-compliant review identified 73 patients with 94 previously untreated CLM that underwent RFA between March 2003 and May 2010, resulting in an ablation zone completely covering the tumor 4-8 weeks after RFA dynamic CT. Comparing the pre- with the post-RFA CT, the minimal margin size was categorized to 0, 1-5, 6-10, and 11-15 mm. Follow-up included CT every 2-4 months. Kaplan-Meier methodology and Cox regression analysis were used to evaluate the effect of the minimal margin size, tumor location, size, and proximity to a vessel on LTP. Forty-five of 94 (47.9 %) CLM progressed locally. Median LTP-free survival (LPFS) was 16 months. Two-year LPFS rates for ablated CLM with minimal margin of 0, 1-5 mm, 6-10 mm, 11-15 mm were 26, 46, 74, and 80 % (p < 0.011). Minimal margin (p = 0.002) and tumor size (p = 0.028) were independent risk factors for LTP. The risk for LTP decreased by 46 % for each 5-mm increase in minimal margin size, whereas each additional 5-mm increase in tumor size increased the risk of LTP by 22 %. An ablation zone with a minimal margin uniformly larger than 5 mm 4-8 weeks postablation CT is associated with the best local tumor control.