Science.gov

Sample records for above-groundelectromagnetic impedance measurements

  1. Impedance Measurement Box

    ScienceCinema

    Christophersen, Jon; Morrison, Bill

    2018-02-14

    Energy storage devices, primarily batteries, are now more important to consumers, industries and the military. With increasing technical complexity and higher user expectations, there is also a demand for highly accurate state-of-health battery assessment techniques. IMB incorporates patented, proprietary, and tested capabilities using control software and hardware that can be part of an embedded monitoring system. IMB directly measures the wideband impedance spectrum in seconds during battery operation with no significant impact on service life. It also can be applied to batteries prior to installation, confirming health before entering active service, as well as during regular maintenance. For more information about this project, visit http://www.inl.gov/rd100/2011/impedance-measurement-box/

  2. Monolithically compatible impedance measurement

    DOEpatents

    Ericson, Milton Nance; Holcomb, David Eugene

    2002-01-01

    A monolithic sensor includes a reference channel and at least one sensing channel. Each sensing channel has an oscillator and a counter driven by the oscillator. The reference channel and the at least one sensing channel being formed integrally with a substrate and intimately nested with one another on the substrate. Thus, the oscillator and the counter have matched component values and temperature coefficients. A frequency determining component of the sensing oscillator is formed integrally with the substrate and has an impedance parameter which varies with an environmental parameter to be measured by the sensor. A gating control is responsive to an output signal generated by the reference channel, for terminating counting in the at least one sensing channel at an output count, whereby the output count is indicative of the environmental parameter, and successive ones of the output counts are indicative of changes in the environmental parameter.

  3. Constant current loop impedance measuring system that is immune to the effects of parasitic impedances

    NASA Technical Reports Server (NTRS)

    Anderson, Karl F. (Inventor)

    1994-01-01

    A constant current loop measuring system is provided for measuring a characteristic of an environment. The system comprises a first impedance positionable in the environment, a second impedance coupled in series with said first impedance and a parasitic impedance electrically coupled to the first and second impedances. A current generating device, electrically coupled in series with the first and second impedances, provides a constant current through the first and second impedances to produce first and second voltages across the first and second impedances, respectively, and a parasitic voltage across the parasitic impedance. A high impedance voltage measuring device measures a voltage difference between the first and second voltages independent of the parasitic voltage to produce a characteristic voltage representative of the characteristic of the environment.

  4. Protein Aggregation Measurement through Electrical Impedance Spectroscopy

    NASA Astrophysics Data System (ADS)

    Affanni, A.; Corazza, A.; Esposito, G.; Fogolari, F.; Polano, M.

    2013-09-01

    The paper presents a novel methodology to measure the fibril formation in protein solutions. We designed a bench consisting of a sensor having interdigitated electrodes, a PDMS hermetic reservoir and an impedance meter automatically driven by calculator. The impedance data are interpolated with a lumped elements model and their change over time can provide information on the aggregation process. Encouraging results have been obtained by testing the methodology on K-casein, a protein of milk, with and without the addition of a drug inhibiting the aggregation. The amount of sample needed to perform this measurement is by far lower than the amount needed by fluorescence analysis.

  5. Impedance measurements of the human cochlear partition

    NASA Astrophysics Data System (ADS)

    Raufer, Stefan; Nakajima, Hideko H.

    2018-05-01

    The cochlea is a mechanical frequency analyzer, owing its characteristics to the impedance of the cochlear partition. In humans, the impedance of the partition has not been measured directly, and estimates of the stiffness (a principal component of the impedance) are based on loose assumptions. In this study, we examine not only the stiffness of the basilar membrane (BM), but also the osseous spiral lamina (OSL), which, in human, vibrates substantially. We hypothesize that the OSL contributes significantly to the volume stiffness of the cochlear partition (CP). We measured velocities of the BM and OSL at different radial locations 1 mm from the base of the cochlea in a fresh human cadaveric specimen. Simultaneously, we measured intracochlear pressures on the other side of the partition, in scala vestibuli. With the velocity and pressure measurements we can estimate the specific acoustic impedance of the BM and OSL (Z = p/v). At frequencies well below the resonant frequency, the stiffness of these structures can be extracted by multiplying the impedance by the radian frequency. The specific acoustic stiffness was found to be 1.2 GPa/m on the BM, 6 GPa/m at the juncture where the BM attaches to the OSL, and 10 GPa/m at the midpoint of the OSL. A beam model, appropriate to model the radial motion of the BM in guinea pig or gerbil, cannot describe the displacement of the human CP in the base. Instead, we find that the OSL is hinged near the modiolus and vibrates significantly near the connection to the more compliant BM, contributing greatly the volume compliance of the CP.

  6. Bioelectrical impedance analysis. What does it measure?

    NASA Technical Reports Server (NTRS)

    Schoeller, D. A.

    2000-01-01

    Bioelectrical impedance analysis (BIA) has been proposed for measuring fat-free mass, total body water, percent fat, body cell mass, intracellular water, and extracellular water: a veritable laboratory in a box. Although it is unlikely that BIA is quite this versatile, correlations have been demonstrated between BIA and all of these body compartments. At the same time, it is known that all of the compartments are correlated among themselves. Because of this, it is difficult to determine whether BIA is specific for any or all of these compartments. To investigate this question, we induced acute changes in total body water and its compartments over a 3-h period. Using this approach, we demonstrated that multifrequency BIA, using the Cole-Cole model to calculate the zero frequency and infinite frequency resistance, measures extracellular and intracellular water.

  7. Baseline impedance measured during high-resolution esophageal impedance manometry reliably discriminates GERD patients.

    PubMed

    Ravi, K; Geno, D M; Vela, M F; Crowell, M D; Katzka, D A

    2017-05-01

    Baseline impedance measured with ambulatory impedance pH monitoring (MII-pH) and a mucosal impedance catheter detects gastroesophageal reflux disease (GERD). However, these tools are limited by cost or patient tolerance. We investigated whether baseline impedance measured during high-resolution impedance manometry (HRIM) distinguishes GERD patients from controls. Consecutive patients with clinical HRIM and MII-pH testing were identified. Gastroesophageal reflux disease was defined by esophageal pH <4 for ≥5% of both the supine and total study time, whereas controls had an esophageal pH <4 for ≤3% of the study performed off PPI. Baseline impedance was measured over 15 seconds during the landmark period of HRIM and over three 10 minute intervals during the overnight period of MII-pH. Among 29 GERD patients and 26 controls, GERD patients had a mean esophageal acid exposure time of 22.7% compared to 1.2% in controls (P<.0001). Mean baseline impedance during HRIM was lower in GERD (1061 Ω) than controls (2814 Ω) (P<.0001). Baseline mucosal impedance measured during HRIM and MII-pH correlated (r=0.59, P<.0001). High-resolution esophageal manometry baseline impedance had high diagnostic accuracy for GERD, with an area under the curve (AUC) of 0.931 on receiver operating characteristics (ROC) analysis. A HRIM baseline impedance threshold of 1582 Ω had a sensitivity of 86.2% and specificity of 88.5% for GERD, with a positive predictive value of 89.3% and negative predictive value of 85.2%. Baseline impedance measured during HRIM can reliably discriminate GERD patients with at least moderate esophageal acid exposure from controls. This diagnostic tool may represent an accurate, cost-effective, and less invasive test for GERD. © 2016 John Wiley & Sons Ltd.

  8. Factors confounding impedance catheter volume measurements in vitro.

    PubMed

    Bielefeld, M R; Cabreriza, S E; Spotnitz, H M

    1993-06-01

    The impedance catheter allows continuous measurement of ventricular volume. External influences have been described as causing parallel shifts in impedance-measured volumes; however, factors affecting impedance measurements in a nonparallel manner have not been fully characterized. Accordingly, an impedance catheter was placed inside a latex balloon into which known volumes of normal saline solution were injected. Conductive and nonconductive materials were individually placed within the balloon. Impedance was measured with materials touching (T) or not touching (NT) the catheter. Impedance-measured volumes were plotted versus actual volumes. Compared with the line of identity (LID), a statistical difference (p < 0.05) was found in the slopes in the presence of metallic objects only. These included a pacing lead (T, NT) (mT = 1.32m mNT = 1.29 versus mLID = 1.00), titanium (T) (mT = 1.68 versus mLID = 1.00), and aluminum (NT) (mNT = 0.72 versus mLID = 1.00). These changes in slope indicate nonparallel effects on impedance that confound the ability of the impedance catheter to determine volumes in vitro. These observations imply that serial calibration of both the slope constant (alpha) and the intercept (parallel conductance) of impedance may be necessary for in vivo measurements of ventricular volume based on impedance in the presence of metallic objects.

  9. Operators manual for a computer controlled impedance measurement system

    NASA Astrophysics Data System (ADS)

    Gordon, J.

    1987-02-01

    Operating instructions of a computer controlled impedance measurement system based in Hewlett Packard instrumentation are given. Hardware details, program listings, flowcharts and a practical application are included.

  10. Plasma Diagnostics by Antenna Impedance Measurements

    NASA Technical Reports Server (NTRS)

    Swenson, C. M.; Baker, K. D.; Pound, E.; Jensen, M. D.

    1993-01-01

    The impedance of an electrically short antenna immersed in a plasma provides an excellent in situ diagnostic tool for electron density and other plasma parameters. By electrically short we mean that the wavelength of the free-space electromagnetic wave that would be excited at the driving frequency is much longer than the physical size of the antenna. Probes using this impedance technique have had a long history with sounding rockets and satellites, stretching back to the early 1960s. This active technique could provide information on composition and temperature of plasmas for comet or planetary missions. Advantages of the impedance probe technique are discussed and two classes of instruments built and flown by SDL-USU for determining electron density (the capacitance and plasma frequency probes) are described.

  11. Impedance measurements for detecting pathogens attached to antibodies

    DOEpatents

    Miles, Robin R.; Venkateswaran, Kodumudi S.; Fuller, Christopher K.

    2004-12-28

    The use of impedance measurements to detect the presence of pathogens attached to antibody-coated beads. In a fluidic device antibodies are immobilized on a surface of a patterned interdigitated electrode. Pathogens in a sample fluid streaming past the electrode attach to the immobilized antibodies, which produces a change in impedance between two adjacent electrodes, which impedance change is measured and used to detect the presence of a pathogen. To amplify the signal, beads coated with antibodies are introduced and the beads would stick to the pathogen causing a greater change in impedance between the two adjacent electrodes.

  12. Whole-body impedance--what does it measure?

    PubMed

    Foster, K R; Lukaski, H C

    1996-09-01

    Although the bioelectrical impedance technique is widely used in human nutrition and clinical research, an integrated summary of the biophysical and bioelectrical bases of this approach is lacking. We summarize the pertinent electrical phenomena relevant to the application of the impedance technique in vivo and discuss the relations between electrical measurements and biological conductor volumes. Key terms in the derivation of bioelectrical impedance analysis are described and the relation between the electrical properties of tissues and tissue structure is discussed. The relation between the impedance of an object and its geometry, scale, and intrinsic electrical properties is also discussed. Correlations between whole-body impedance measurements and various bioconductor volumes, such as total body water and fat-free mass, are experimentally well established; however, the reason for the success of the impedence technique is much less clear. The bioengineering basis for the technique is critically presented and considerations are proposed that might help to clarify the method and potentially improve its sensitivity.

  13. Measurement and simulation of the RHIC abort kicker longitudinal impedence

    SciTech Connect

    Abreu,N.P.; Hahn,H.; Choi, E.

    2009-09-01

    In face of the new upgrades for RHIC the longitudinal impedance of the machine plays an important role in setting the threshold for instabilities and the efficacy of some systems. In this paper we describe the measurement of the longitudinal impedance of the abort kicker for RHIC as well as computer simulations of the structure. The impedance measurement was done by the S{sub 21} wire method covering the frequency range from 9 kHz to 2.5 GHz. We observed a sharp resonance peak around 10 MHz and a broader peak around 20 MHz in both, the real and imaginary part, ofmore » the Z/n. These two peaks account for a maximum imaginary longitudinal impedance of j15 {Omega}, a value an order of magnitude larger than the estimated value of j0.2 {Omega}, which indicates that the kicker is one of the main sources of longitudinal impedance in the machine. A computer model was constructed for simulations in the CST MWS program. Results for the magnet input and the also the beam impedance are compared to the measurements. A more detail study of the system properties and possible changes to reduce the coupling impedance are presented.« less

  14. Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis

    PubMed Central

    Weyer, Sören; Pauly, Karolin; Napp, Andreas; Dreher, Michael; Leonhardt, Steffen; Marx, Nikolaus; Schauerte, Patrick; Mischke, Karl

    2015-01-01

    Background. Bioelectrical impedance spectroscopy is applied to measure changes in tissue composition. The aim of this study was to evaluate its feasibility in measuring the fluid shift after thoracentesis in patients with pleural effusion. Methods. 45 participants (21 with pleural effusion and 24 healthy subjects) were included. Bioelectrical impedance was analyzed for “Transthoracic,” “Foot to Foot,” “Foot to Hand,” and “Hand to Hand” vectors in low and high frequency domain before and after thoracentesis. Healthy subjects were measured at a single time point. Results. The mean volume of removed pleural effusion was 1169 ± 513 mL. The “Foot to Foot,” “Hand to Hand,” and “Foot to Hand” vector indicated a trend for increased bioelectrical impedance after thoracentesis. Values for the low frequency domain in the “Transthoracic” vector increased significantly (P < 0.001). A moderate correlation was observed between the amount of removed fluid and impedance change in the low frequency domain using the “Foot to Hand” vector (r = −0.7). Conclusion. Bioelectrical impedance changes in correlation with the thoracic fluid level. It was feasible to monitor significant fluid shifts and loss after thoracentesis in the “Transthoracic” vector by means of bioelectrical impedance spectroscopy. The trial is registered with Registration Numbers IRB EK206/11 and NCT01778270. PMID:25861647

  15. Smart mug to measure hand's geometrical mechanical impedance.

    PubMed

    Hondori, Hossein Mousavi; Tech, Ang Wei

    2011-01-01

    A novel device, which looks like a mug, has been proposed for measuring the impedance of human hand. The device is designed to have convenient size and light weight similar to an ordinary coffee mug. It contains a 2-axis inertia sensor to monitor vibration and a small motor to carry an eccentric mass (m=100 gr, r=2 cm, rpm=600). The centrifugal force due to the rotating mass applies a dynamic force to the hand that holds the mug. Correlation of the acceleration signals with the perturbing force gives the geometrical mechanical impedance. Experimental results on a healthy subject shows that impedance is posture dependant while it changes with the direction of the applied perturbing force. For nine postures the geometrical impedance is obtained all of which have elliptical shapes. The method can be used for assessment of spasticity and monitoring stability in patients with stroke or similar problems.

  16. Quantitative impedance measurements for eddy current model validation

    NASA Astrophysics Data System (ADS)

    Khan, T. A.; Nakagawa, N.

    2000-05-01

    This paper reports on a series of laboratory-based impedance measurement data, collected by the use of a quantitatively accurate, mechanically controlled measurement station. The purpose of the measurement is to validate a BEM-based eddy current model against experiment. We have therefore selected two "validation probes," which are both split-D differential probes. Their internal structures and dimensions are extracted from x-ray CT scan data, and thus known within the measurement tolerance. A series of measurements was carried out, using the validation probes and two Ti-6Al-4V block specimens, one containing two 1-mm long fatigue cracks, and the other containing six EDM notches of a range of sizes. Motor-controlled XY scanner performed raster scans over the cracks, with the probe riding on the surface with a spring-loaded mechanism to maintain the lift off. Both an impedance analyzer and a commercial EC instrument were used in the measurement. The probes were driven in both differential and single-coil modes for the specific purpose of model validation. The differential measurements were done exclusively by the eddyscope, while the single-coil data were taken with both the impedance analyzer and the eddyscope. From the single-coil measurements, we obtained the transfer function to translate the voltage output of the eddyscope into impedance values, and then used it to translate the differential measurement data into impedance results. The presentation will highlight the schematics of the measurement procedure, a representative of raw data, explanation of the post data-processing procedure, and then a series of resulting 2D flaw impedance results. A noise estimation will be given also, in order to quantify the accuracy of these measurements, and to be used in probability-of-detection estimation.—This work was supported by the NSF Industry/University Cooperative Research Program.

  17. MEASURED TRANSVERSE COUPLING IMPEDANCE OF RHIC INJECTION AND ABORT KICKERS.

    SciTech Connect

    HAHN,H.; DAVINO,D.

    2001-06-18

    Concerns regarding possible transverse instabilities in RHIC and the SNS pointed to the need for measurements of the transverse coupling impedance of ring components. The impedance of the RHIC injection and abort kicker was measured using the conventional method based on the S{sub 21} forward transmission coefficient. A commercial 450 {Omega} twin-wire Lecher line were used and the data was interpreted via the log-formula. All measurements, were performed in test stands fully representing operational conditions including pulsed power supplies and connecting cables. The measured values for the transverse coupling impedance in kick direction and perpendicular to it are comparable inmore » magnitude, but differ from Handbook predictions.« less

  18. Energy storage cell impedance measuring apparatus, methods and related systems

    DOEpatents

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.

    2017-12-26

    Energy storage cell impedance testing devices, circuits, and related methods are disclosed. An energy storage cell impedance measuring device includes a sum of sinusoids (SOS) current excitation circuit including differential current sources configured to isolate a ground terminal of the differential current sources from a positive terminal and a negative terminal of an energy storage cell. A method includes applying an SOS signal comprising a sum of sinusoidal current signals to the energy storage cell with the SOS current excitation circuit, each of the sinusoidal current signals oscillating at a different one of a plurality of different frequencies. The method also includes measuring an electrical signal at a positive terminal and a negative terminal of the energy storage cell, and computing an impedance of the energy storage cell at each of the plurality of different frequencies using the measured electrical signal.

  19. [An instrument for estimating human body composition using impedance measurement].

    PubMed

    Yin, J; Peng, C

    1997-03-01

    According to the impedance feature of biological tissue, the instrument was designed at 1, 5, 10, 50, 100kHz to measure human impedance, and then to calculate human FAT, FFM, FAT%, TBW, ECW, ICW and so on. A 8031 singlechip microprocessor contacuting used as a control center in the instrument. The part of electric circuit contacuting human body in the instrument was unreally earthing. The instrument was safty, effective, repeatable, and easily manpulative. Prelimintary clinical experiment showed the results measured with the instrument could effectively reflect practical, status of human composition.

  20. Sensorless battery temperature measurements based on electrochemical impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Raijmakers, L. H. J.; Danilov, D. L.; van Lammeren, J. P. M.; Lammers, M. J. G.; Notten, P. H. L.

    2014-02-01

    A new method is proposed to measure the internal temperature of (Li-ion) batteries. Based on electrochemical impedance spectroscopy measurements, an intercept frequency (f0) can be determined which is exclusively related to the internal battery temperature. The intercept frequency is defined as the frequency at which the imaginary part of the impedance is zero (Zim = 0), i.e. where the phase shift between the battery current and voltage is absent. The advantage of the proposed method is twofold: (i) no hardware temperature sensors are required anymore to monitor the battery temperature and (ii) the method does not suffer from heat transfer delays. Mathematical analysis of the equivalent electrical-circuit, representing the battery performance, confirms that the intercept frequency decreases with rising temperatures. Impedance measurements on rechargeable Li-ion cells of various chemistries were conducted to verify the proposed method. These experiments reveal that the intercept frequency is clearly dependent on the temperature and does not depend on State-of-Charge (SoC) and aging. These impedance-based sensorless temperature measurements are therefore simple and convenient for application in a wide range of stationary, mobile and high-power devices, such as hybrid- and full electric vehicles.

  1. AC orbit bump method of local impedance measurement

    SciTech Connect

    Smaluk, Victor; Yang, Xi; Blednykh, Alexei

    A fast and precise technique of local impedance measurement has been developed and tested at NSLS-II. This technique is based on in-phase sine-wave (AC) excitation of four fast correctors adjacent to the vacuum chamber section, impedance of which is measured. The beam position is measured using synchronous detection. Use of the narrow-band sine-wave signal allows us to improve significantly the accuracy of the orbit bump method. Beam excitation by fast correctors results in elimination of the systematic error caused by hysteresis effect. The systematic error caused by orbit drift is also eliminated because the measured signal is not affected bymore » the orbit motion outside the excitation frequency range. In this article, the measurement technique is described and the result of proof-of-principle experiment carried out at NSLS-II is presented.« less

  2. AC orbit bump method of local impedance measurement

    DOE PAGES

    Smaluk, Victor; Yang, Xi; Blednykh, Alexei; ...

    2017-08-04

    A fast and precise technique of local impedance measurement has been developed and tested at NSLS-II. This technique is based on in-phase sine-wave (AC) excitation of four fast correctors adjacent to the vacuum chamber section, impedance of which is measured. The beam position is measured using synchronous detection. Use of the narrow-band sine-wave signal allows us to improve significantly the accuracy of the orbit bump method. Beam excitation by fast correctors results in elimination of the systematic error caused by hysteresis effect. The systematic error caused by orbit drift is also eliminated because the measured signal is not affected bymore » the orbit motion outside the excitation frequency range. In this article, the measurement technique is described and the result of proof-of-principle experiment carried out at NSLS-II is presented.« less

  3. An 8-channel skin impedance measurement system for acupuncture research.

    PubMed

    Thong, Tran; Colbert, Agatha P; Larsen, Adrian P

    2009-01-01

    An 8-channel skin impedance measurement system for acupuncture research has been developed. The underlying model of the skin used is a parallel R & C network. Pulses are used to measure the R and C values. The measurement circuit is time multiplexed across the 8 channels at the rate of 2 measurements per second, leading to a complete set of measurements every 4 seconds. In static tests, the system has been operational for over 2 days of continuous measurements. In preliminary human tests, measurements over 2 hours have been collected per subject.

  4. Measurement of intestinal edema using an impedance analyzer circuit.

    PubMed

    Radhakrishnan, Ravi S; Shah, Kunal; Xue, Hasen; Moore-Olufemi, Stacey D; Moore, Frederick A; Weisbrodt, Norman W; Allen, Steven J; Gill, Brijesh; Cox, Charles S

    2007-03-01

    Acute intestinal edema adversely affects intestinal transit, permeability, and contractility. Current resuscitation modalities, while effective, are associated with development of acute intestinal edema. Knowledge of levels of tissue edema would allow clinicians to monitor intestinal tissue water and may help prevent the detrimental effects of edema. However, there is no simple method to measure intestinal tissue water without biopsy. We sought to develop a tissue impedance analyzer to measure tissue edema, without the need for invasive biopsy. Oscillating voltage input was applied to the analyzer circuit and an oscilloscope measured the voltage output across any load. Rats were randomized to three groups: sham, mild edema (80 mL/kg of NS resuscitation), and severe edema (80 mL/kg of NS resuscitation with intestinal venous hypertension). Intestinal edema was measured by wet-to-dry tissue weight ratio. Bowel impedance was measured and converted to capacitance using a standard curve. Acute intestinal edema causes a significant increase in bowel capacitance. This capacitance can be used to predict tissue water concentration. Using an impedance analyzer circuit, it is possible to measure intestinal edema reliably and quickly. This may prove to be a useful tool in the resuscitation of critically ill patients.

  5. Determination of Complex Microcalorimeter Parameters with Impedance Measurements

    NASA Technical Reports Server (NTRS)

    Saab, T.; Bandler, S. R.; Chervenak, J.; Figueroa-Feliciano, E.; Finkbeiner, F.; Iyomoto, N.; Kelley, R.; Kilbourne, C. A.; Lindeman, M. A.; Porter, F. S.; hide

    2005-01-01

    The proper understanding and modeling of a microcalorimeter s response requires the accurate knowledge of a handful of parameters, such as C, G, alpha, . . . . While a few of these, such 8s the normal state resistance and the total thermal conductance to the heat bath (G) are directly determined from the DC IV characteristics, some others, notoriously the heat capacity (C) and alpha, appear in degenerate combinations in most measurable quantities. The case of a complex microcalorimeter, i.e. one in which the absorber s heat capacity is connected by a finite thermal impedance to the sensor, and subsequently by another thermal impedance to the heat bath, results in an added ambiguity in the determination of the individual C's and G's. In general, the dependence of the microcalorimeter s complex impedance on these parameters varies with frequency. This variation allows us to determine the individual parameters by fitting the prediction of the microcalorimeter model to the impedance data. We describe in this paper our efforts at characterizing the Goddard X-ray microcalorimeters. Using the parameters determined with this method we them compare the pulse shape and noise spectra predicted by the microcalorimeter model to data taken with the same devices.

  6. Damage Diagnosis in Semiconductive Materials Using Electrical Impedance Measurements

    NASA Technical Reports Server (NTRS)

    Ross, Richard W.; Hinton, Yolanda L.

    2008-01-01

    Recent aerospace industry trends have resulted in an increased demand for real-time, effective techniques for in-flight structural health monitoring. A promising technique for damage diagnosis uses electrical impedance measurements of semiconductive materials. By applying a small electrical current into a material specimen and measuring the corresponding voltages at various locations on the specimen, changes in the electrical characteristics due to the presence of damage can be assessed. An artificial neural network uses these changes in electrical properties to provide an inverse solution that estimates the location and magnitude of the damage. The advantage of the electrical impedance method over other damage diagnosis techniques is that it uses the material as the sensor. Simple voltage measurements can be used instead of discrete sensors, resulting in a reduction in weight and system complexity. This research effort extends previous work by employing finite element method models to improve accuracy of complex models with anisotropic conductivities and by enhancing the computational efficiency of the inverse techniques. The paper demonstrates a proof of concept of a damage diagnosis approach using electrical impedance methods and a neural network as an effective tool for in-flight diagnosis of structural damage to aircraft components.

  7. Nuclear radiation-warning detector that measures impedance

    DOEpatents

    Savignac, Noel Felix; Gomez, Leo S; Yelton, William Graham; Robinson, Alex; Limmer, Steven

    2013-06-04

    This invention is a nuclear radiation-warning detector that measures impedance of silver-silver halide on an interdigitated electrode to detect light or radiation comprised of alpha particles, beta particles, gamma rays, X rays, and/or neutrons. The detector is comprised of an interdigitated electrode covered by a layer of silver halide. After exposure to alpha particles, beta particles, X rays, gamma rays, neutron radiation, or light, the silver halide is reduced to silver in the presence of a reducing solution. The change from the high electrical resistance (impedance) of silver halide to the low resistance of silver provides the radiation warning that detected radiation levels exceed a predetermined radiation dose threshold.

  8. Body Fat Measurement: Weighing the Pros and Cons of Electrical Impedance.

    ERIC Educational Resources Information Center

    Nash, Heyward L.

    1985-01-01

    Research technologists have developed electrical impedance units in response to demand for a convenient and reliable method of measuring body fat. Accuracy of impedance measures versus calipers and underwater weighing are discussed. (MT)

  9. Auditory evoked field measurement using magneto-impedance sensors

    SciTech Connect

    Wang, K., E-mail: o-kabou@echo.nuee.nagoya-u.ac.jp; Tajima, S.; Song, D.

    The magnetic field of the human brain is extremely weak, and it is mostly measured and monitored in the magnetoencephalography method using superconducting quantum interference devices. In this study, in order to measure the weak magnetic field of the brain, we constructed a Magneto-Impedance sensor (MI sensor) system that can cancel out the background noise without any magnetic shield. Based on our previous studies of brain wave measurements, we used two MI sensors in this system for monitoring both cerebral hemispheres. In this study, we recorded and compared the auditory evoked field signals of the subject, including the N100 (ormore » N1) and the P300 (or P3) brain waves. The results suggest that the MI sensor can be applied to brain activity measurement.« less

  10. Optimization of Acoustic Pressure Measurements for Impedance Eduction

    NASA Technical Reports Server (NTRS)

    Jones, M. G.; Watson, W. R.; Nark, D. M.

    2007-01-01

    As noise constraints become increasingly stringent, there is continued emphasis on the development of improved acoustic liner concepts to reduce the amount of fan noise radiated to communities surrounding airports. As a result, multiple analytical prediction tools and experimental rigs have been developed by industry and academia to support liner evaluation. NASA Langley has also placed considerable effort in this area over the last three decades. More recently, a finite element code (Q3D) based on a quasi-3D implementation of the convected Helmholtz equation has been combined with measured data acquired in the Langley Grazing Incidence Tube (GIT) to reduce liner impedance in the presence of grazing flow. A new Curved Duct Test Rig (CDTR) has also been developed to allow evaluation of liners in the presence of grazing flow and controlled, higher-order modes, with straight and curved waveguides. Upgraded versions of each of these two test rigs are expected to begin operation by early 2008. The Grazing Flow Impedance Tube (GFIT) will replace the GIT, and additional capabilities will be incorporated into the CDTR. The current investigation uses the Q3D finite element code to evaluate some of the key capabilities of these two test rigs. First, the Q3D code is used to evaluate the microphone distribution designed for the GFIT. Liners ranging in length from 51 to 610 mm are investigated to determine whether acceptable impedance eduction can be achieved with microphones placed on the wall opposite the liner. This analysis indicates the best results are achieved for liner lengths of at least 203 mm. Next, the effects of moving this GFIT microphone array to the wall adjacent to the liner are evaluated, and acceptable results are achieved if the microphones are placed off the centerline. Finally, the code is used to investigate potential microphone placements in the CDTR rigid wall adjacent to the wall containing an acoustic liner, to determine if sufficient fidelity can be

  11. [The functional assessment of the upper urinary tract by the methods of 2-frequency impedance measurement and multichannel impedance ureterography].

    PubMed

    Mudraia, I S; Kirpatovskiĭ, V I

    1993-01-01

    The paper describes impedance methods of investigating upper urinary tracts (UUT) which may serve adjuvants in the diagnosis of the urinary tract wall disturbances due to diseases caused by impaired urine evacuation from the kidney and which may prove helpful in the choice of therapeutic policy, evaluation of the postoperative period and outcomes prognosis. UUT impedance tests can be performed during endoscopic manipulations or under open operative interventions. Two-frequency impedancemetry allows rapid detection of non-functioning UUT parts or sclerosal sites of the UUT wall, relevant criteria being the ratio of basic impedances of the site under low and high scanning current. This value is computed by an urological two-frequency impedancemeter IDU-M. To assess the UUT wall functionally, use should be made of 6-channel urological rheograph REUR-6 providing multichannel registration of immediate impedance ureterograms. In this manner one can obtain qualitative and quantitative assessment of the ureteral peristalsis through its all length, the criteria being the amplitude of impedance ureterographic complexes, their shape, duration, frequency, rhythm, sequence and rate of distribution. Loading tests increase the accuracy of UUT impedance measurements, are able to define compensatory reserves of the wall contractility. The introduction of rheological methods in urological practice makes broader the armory of diagnostic techniques in urology, upgrade pathogenetic validity of surgical and therapeutic measures.

  12. Detection of Chamber Conditioning Through Optical Emission and Impedance Measurements

    NASA Technical Reports Server (NTRS)

    Cruden, Brett A.; Rao, M. V. V. S.; Sharma, Surendra P.; Meyyappan, Meyya

    2001-01-01

    During oxide etch processes, buildup of fluorocarbon residues on reactor sidewalls can cause run-to-run drift and will necessitate some time for conditioning and seasoning of the reactor. Though diagnostics can be applied to study and understand these phenomena, many of them are not practical for use in an industrial reactor. For instance, measurements of ion fluxes and energy by mass spectrometry show that the buildup of insulating fluorocarbon films on the reactor surface will cause a shift in both ion energy and current in an argon plasma. However, such a device cannot be easily integrated into a processing system. The shift in ion energy and flux will be accompanied by an increase in the capacitance of the plasma sheath. The shift in sheath capacitance can be easily measured by a common commercially available impedance probe placed on the inductive coil. A buildup of film on the chamber wall is expected to affect the production of fluorocarbon radicals, and thus the presence of such species in the optical emission spectrum of the plasma can be monitored as well. These two techniques are employed on a GEC (Gaseous Electronics Conference) Reference Cell to assess the validity of optical emission and impedance monitoring as a metric of chamber conditioning. These techniques are applied to experimental runs with CHF3 and CHF3/O2/Ar plasmas, with intermediate monitoring of pure argon plasmas as a reference case for chamber conditions.

  13. Mechanical impedance measurements for improved cost-effective process monitoring

    NASA Astrophysics Data System (ADS)

    Clopet, Caroline R.; Pullen, Deborah A.; Badcock, Rodney A.; Ralph, Brian; Fernando, Gerard F.; Mahon, Steve W.

    1999-06-01

    The aerospace industry has seen a considerably growth in composite usage over the past ten years, especially with the development of cost effective manufacturing techniques such as Resin Transfer Molding and Resin Infusion under Flexible Tooling. The relatively high cost of raw material and conservative processing schedules has limited their growth further in non-aerospace technologies. In-situ process monitoring has been explored for some time as a means to improving the cost efficiency of manufacturing with dielectric spectroscopy and optical fiber sensors being the two primary techniques developed to date. A new emerging technique is discussed here making use of piezoelectric wafers with the ability to sense not only aspects of resin flow but also to detect the change in properties of the resin as it cures. Experimental investigations to date have shown a correlation between mechanical impedance measurements and the mechanical properties of cured epoxy systems with potential for full process monitoring.

  14. An Effective Measured Data Preprocessing Method in Electrical Impedance Tomography

    PubMed Central

    Yu, Chenglong; Yue, Shihong; Wang, Jianpei; Wang, Huaxiang

    2014-01-01

    As an advanced process detection technology, electrical impedance tomography (EIT) has widely been paid attention to and studied in the industrial fields. But the EIT techniques are greatly limited to the low spatial resolutions. This problem may result from the incorrect preprocessing of measuring data and lack of general criterion to evaluate different preprocessing processes. In this paper, an EIT data preprocessing method is proposed by all rooting measured data and evaluated by two constructed indexes based on all rooted EIT measured data. By finding the optimums of the two indexes, the proposed method can be applied to improve the EIT imaging spatial resolutions. In terms of a theoretical model, the optimal rooting times of the two indexes range in [0.23, 0.33] and in [0.22, 0.35], respectively. Moreover, these factors that affect the correctness of the proposed method are generally analyzed. The measuring data preprocessing is necessary and helpful for any imaging process. Thus, the proposed method can be generally and widely used in any imaging process. Experimental results validate the two proposed indexes. PMID:25165735

  15. Impedance measurement of Cobalt doped ZnO Quantum dots

    NASA Astrophysics Data System (ADS)

    Tiwari, Ram; Kaphle, Amrit; Hari, Parameswar

    We investigated structural, thermal and electrical properties of ZnO Quantum dots grown by precipitation method. QDs were spin coated on ITO and annealed at various temperatures ranging from 1000C to 300 0C. ZnO QDs were doped with cobalt for concentration ranging from 0-15%. XRD measurement showed increase in bond length, strain, dislocation density and Cell volume as the doping level varied from 0% to 15%. Impedance Spectroscopy measurements represented by Cole-Cole plot showed reduction in resistance as the cobalt doping concentration increased from 0-15%. Thermal activation energy was obtained by plotting resistivity Vs temperature for doped samples at temperatures from 1000C to 3000C. The thermal activation energy decreased from 85.13meV to 58.21meV as doping increased from 0-15%. Relaxation time was extracted by fitting data to RC model. Relaxation time varied from 61.57 ns to 3.76 ns as the cobalt concentration increased from 0% to 15%. We will also discuss applications of cobalt doped ZnO QDs on improving conversion efficiency of solar cells.

  16. Using impedance measurements for detecting pathogens trapped in an electric field

    DOEpatents

    Miles, Robin R.

    2004-07-20

    Impedance measurements between the electrodes in an electric field is utilized to detect the presence of pathogens trapped in the electric field. Since particles trapped in a field using the dielectiphoretic force changes the impedance between the electrodes by changing the dielectric material between the electrodes, the degree of particle trapping can be determined by measuring the impedance. This measurement is used to determine if sufficient pathogen have been collected to analyze further or potentially to identify the pathogen.

  17. Validity of total and segmental impedance measurements for prediction of body composition across ethnic population groups.

    PubMed

    Deurenberg, P; Deurenberg-Yap, M; Schouten, F J M

    2002-03-01

    To test the impact of body build factors on the validity of impedance-based body composition predictions across (ethnic) population groups and to study the suitability of segmental impedance measurements. Cross-sectional observational study. Ministry of Health and School of Physical Education, Nanyang Technological University, Singapore. A total of 291 female and male Chinese, Malays and Indian Singaporeans, aged 18-69, body mass index (BMI) 16.0-40.2 kg/ m2. Anthropometric parameters were measured in addition to impedance (100 kHz) of the total body, arms and legs. Impedance indexes were calculated as height2/impedance. Arm length (span) and leg length (sitting height), wrist and knee width were measured from which body build indices were calculated. Total body water (TBW) was measured using deuterium oxide dilution. Extra cellular water (ECW) was measured using bromide dilution. Body fat percentage was determined using a chemical four-compartment model. The bias of TBW predicted from total body impedance index (bias: measured minus predicted TBW) was different among the three ethnic groups, TBW being significantly underestimated in Indians compared to Chinese and Malays. This bias was found to be dependent on body water distribution (ECW/TBW) and parameters of body build, mainly relative (to height) arm length. After correcting for differences in body water distribution and body build parameters the differences in bias across the ethnic groups disappeared. The impedance index using total body impedance was better correlated with TBW than the impedance index of arm or leg impedance, even after corrections for body build parameters. The study shows that ethnic-specific bias of impedance-based prediction formulas for body composition is due mainly to differences in body build among the ethnic groups. This means that the use of 'general' prediction equations across different (ethnic) population groups without prior testing of their validity should be avoided. Total

  18. Measurement of low temperature plasma properties using non-invasive impedance measurements

    NASA Astrophysics Data System (ADS)

    Gillman, Eric; Amatucci, Bill; Tejero, Erik; Blackwell, David

    2017-10-01

    A plasma discharge can be modeled electrically as a combination of capacitors, resistors, and inductors. The plasma, much like an RLC circuit, will have resonances at particular frequencies. The location in frequency space of these resonances provides information about the plasma parameters. These resonances can be detected using impedance measurements, where the AC impedance of the plasma is measured by sweeping the frequency of an AC voltage applied to a sensor and determining the magnitude and phase of the measured current. In this work, an electrode used to sustain a glow discharge is also used as an impedance probe. The novelty of this method is that insertion of a physical probe, which can introduce perturbation and/or contamination, is not necessary. This non-invasive impedance probe method is used to measure the plasma discharge density in various regimes of plasma operation. Experimental results are compared to the basic circuit model results. The potential applications of this diagnostic method and regimes over which this measurement method is valid will be discussed.

  19. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  20. Measuring impedance in congestive heart failure: Current options and clinical applications

    PubMed Central

    Tang, W. H. Wilson; Tong, Wilson

    2011-01-01

    Measurement of impedance is becoming increasingly available in the clinical setting as a tool for assessing hemodynamics and volume status in patients with heart failure. The 2 major categories of impedance assessment are the band electrode method and the implanted device lead method. The exact sources of the impedance signal are complex and can be influenced by physiologic effects such as blood volume, fluid, and positioning. This article provides a critical review of our current understanding and promises of impedance measurements, the techniques that have evolved, as well as the evidence and limitations regarding their clinical applications in the setting of heart failure management. PMID:19249408

  1. Identification of fluids and an interface between fluids by measuring complex impedance

    DOEpatents

    Lee, David O.; Wayland, Jr., James R.

    1989-01-01

    Complex impedance measured over a predefined frequency range is used to determine the identity of different oils in a column. The location of an interface between the oils is determined from the percent frequency effects of the complex impedance measured across the interface.

  2. Identification of fluids and an interface between fluids by measuring complex impedance

    DOEpatents

    Lee, D.O.; Wayland, J.R. Jr.

    1989-12-05

    Complex impedance measured over a predefined frequency range is used to determine the identity of different oils in a column. The location of an interface between the oils is determined from the percent frequency effects of the complex impedance measured across the interface. 5 figs.

  3. Electron density dependence of impedance probe plasma potential measurements

    SciTech Connect

    Walker, D. N.; Blackwell, D. D.; Amatucci, W. E.

    2015-08-15

    In earlier works, we used spheres of various sizes as impedance probes in demonstrating a method of determining plasma potential, φ{sub p}, when the probe radius is much larger than the Debye length, λ{sub D}. The basis of the method in those works [Walker et al., Phys. Plasmas 13, 032108 (2006); ibid. 15, 123506 (2008); ibid. 17, 113503 (2010)] relies on applying a small amplitude signal of fixed frequency to a probe in a plasma and, through network analyzer-based measurements, determining the complex reflection coefficient, Γ, for varying probe bias, V{sub b}. The frequency range of the applied signal ismore » restricted to avoid sheath resonant effects and ion contributions such that ω{sub pi} ≪ ω ≪ ω{sub pe}, where ω{sub pi} is the ion plasma frequency and ω{sub pe} is the electron plasma frequency. For a given frequency and applied bias, both Re(Z{sub ac}) and Im(Z{sub ac}) are available from Γ. When Re(Z{sub ac}) is plotted versus V{sub b}, a minimum predicted by theory occurs at φ{sub p} [Walker et al., Phys. Plasmas 17, 113503 (2010)]. In addition, Im(Z{sub ac}) appears at, or very near, a maximum at φ{sub p}. As n{sub e} decreases and the sheath expands, the minimum becomes harder to discern. The purpose of this work is to demonstrate that when using network analyzer-based measurements, Γ itself and Im(Z{sub ac}) and their derivatives are useful as accompanying indicators to Re(Z{sub ac}) in these difficult cases. We note the difficulties encountered by the most commonly used plasma diagnostic, the Langmuir probe. Spherical probe data is mainly used in this work, although we present limited data for a cylinder and a disk. To demonstrate the effect of lowered density as a function of probe geometry, we compare the cylinder and disk using only the indicator Re(Z{sub ac})« less

  4. Accurate position estimation methods based on electrical impedance tomography measurements

    NASA Astrophysics Data System (ADS)

    Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.

    2017-08-01

    Electrical impedance tomography (EIT) is a technology that estimates the electrical properties of a body or a cross section. Its main advantages are its non-invasiveness, low cost and operation free of radiation. The estimation of the conductivity field leads to low resolution images compared with other technologies, and high computational cost. However, in many applications the target information lies in a low intrinsic dimensionality of the conductivity field. The estimation of this low-dimensional information is addressed in this work. It proposes optimization-based and data-driven approaches for estimating this low-dimensional information. The accuracy of the results obtained with these approaches depends on modelling and experimental conditions. Optimization approaches are sensitive to model discretization, type of cost function and searching algorithms. Data-driven methods are sensitive to the assumed model structure and the data set used for parameter estimation. The system configuration and experimental conditions, such as number of electrodes and signal-to-noise ratio (SNR), also have an impact on the results. In order to illustrate the effects of all these factors, the position estimation of a circular anomaly is addressed. Optimization methods based on weighted error cost functions and derivate-free optimization algorithms provided the best results. Data-driven approaches based on linear models provided, in this case, good estimates, but the use of nonlinear models enhanced the estimation accuracy. The results obtained by optimization-based algorithms were less sensitive to experimental conditions, such as number of electrodes and SNR, than data-driven approaches. Position estimation mean squared errors for simulation and experimental conditions were more than twice for the optimization-based approaches compared with the data-driven ones. The experimental position estimation mean squared error of the data-driven models using a 16-electrode setup was less

  5. Middle ear impedance measurements in large vestibular aqueduct syndrome.

    PubMed

    Bilgen, Cem; Kirkim, Günay; Kirazli, Tayfun

    2009-06-01

    To assess the effect of inner ear pressure on middle ear impedance in patients with large vestibular aqueduct syndrome (LVAS). Data from admittance tympanometry and multifrequency tympanometry on 8 LVAS patients and control subjects were studied. Static acoustic compliance (SAC) values for the ears with stable sensorineural hearing loss (SNHL) were within the limits of the mean values of control groups except for two ears. The resonance frequency (RF) values of the ears with stable SNHL were lower than the mean values of control groups except for three ears. SAC values for the two ears with fluctuating SNHL were lower and the RF values were higher than the mean values of control groups. Decreased SAC values and increased RF values found in the ears with fluctuating SNHL might be an indirect indicator of increased inner ear pressure, while low RF values in the ears with stable SNHL might reflect the decreased inner ear impedance.

  6. Insulator-based DEP with impedance measurements for analyte detection

    SciTech Connect

    Davalos, Rafael V.; Simmons, Blake A.; Crocker, Robert W.

    2010-03-16

    Disclosed herein are microfluidic devices for assaying at least one analyte specie in a sample comprising at least one analyte concentration area in a microchannel having insulating structures on or in at least one wall of the microchannel which provide a nonuniform electric field in the presence of an electric field provided by off-chip electrodes; and a pair of passivated sensing electrodes for impedance detection in a detection area. Also disclosed are assay methods and methods of making.

  7. Impedance measurement using a two-microphone, random-excitation method

    NASA Technical Reports Server (NTRS)

    Seybert, A. F.; Parrott, T. L.

    1978-01-01

    The feasibility of using a two-microphone, random-excitation technique for the measurement of acoustic impedance was studied. Equations were developed, including the effect of mean flow, which show that acoustic impedance is related to the pressure ratio and phase difference between two points in a duct carrying plane waves only. The impedances of a honeycomb ceramic specimen and a Helmholtz resonator were measured and compared with impedances obtained using the conventional standing-wave method. Agreement between the two methods was generally good. A sensitivity analysis was performed to pinpoint possible error sources and recommendations were made for future study. The two-microphone approach evaluated in this study appears to have some advantages over other impedance measuring techniques.

  8. Nondestructive Determination of Moisture Content in Dry Fruits by Impedance and Phase angle measurements

    USDA-ARS?s Scientific Manuscript database

    Impedance (Z), and phase angle (') of a cylindrical parallel-plate capacitor with dry fruits between the plates was measured using a CI meter (Chari’s Impedance meter), at 1 and 9 MHz . Capacitance, C was derived from Z and ', and using the C, ', and Z values of a set of cherries whose moisture con...

  9. Anisotropy of human muscle via non invasive impedance measurements. Frequency dependence of the impedance changes during isometric contractions

    NASA Astrophysics Data System (ADS)

    Kashuri, Hektor

    In this thesis we present non invasive muscle impedance measurements using rotatable probes extending the work done by Aaron et al. (1997) by measuring not only the real part of the impedance but the imaginary part as well. The results reveal orientations of underlying muscle fibers via minima in resistance and reactance versus angle curves, suggesting this method as potentially useful for studying muscle properties in clinical and physiological research. Calculations of the current distribution for a slab of material with anisotropic conductivity show that the current distribution depends strongly on the separation of two current electrodes and as well as on its conducting anisotropy. Forearm muscle impedance measurements at 50 kHz done by Shiffman et al. (2003) had shown that both resistance (R) and reactance (X) increase during isometric contraction. We have extended these measurements in the 3 to 100 kHz range and we found that resistance (R) and reactance (X) both increase and their changes increased or decreased at frequency dependent rates. Analysis based on circuit models of changes in R and X during the short contraction pulses showed that the extra cellular fluid resistance increased by 3.9 +/- 1.4 %, while the capacitance increased by 5.6 +/- 2 %. For long contraction pulses at very low frequencies: (1) there was practically no change in R during contraction, which implies that these changes are due to cellular membrane or intracellular effects with the extra cellular water component not participating, and (2) in post contraction stage there were no morphological changes which means that drifts in R can only be due to physiological changes. Following Shiffman et al. (2003) we measured impedance changes of R and X during a triangular shaped pulse of force generated via isometric forearm muscle contraction at 50 kHz. We measured these changes in 3-100 kHz frequency range for a stair case pulse of forces and the results showed that they are frequency

  10. In situ measurement of tissue impedance using an inductive coupling interface circuit.

    PubMed

    Chiu, Hung-Wei; Chuang, Jia-min; Lu, Chien-Chi; Lin, Wei-Tso; Lin, Chii-Wann; Lin, Mu-Lien

    2013-06-01

    In this work, a method of an inductive coupling impedance measurement (ICIM) is proposed for measuring the nerve impedance of a dorsal root ganglion (DRG) under PRF stimulation. ICIM provides a contactless interface for measuring the reflected impedance by an impedance analyzer with a low excitation voltage of 7 mV. The paper develops a calibration procedure involving a 50-Ω reference resistor to calibrate the reflected resistance for measuring resistance of the nerve in the test. A de-embedding technique to build the equivalent transformer circuit model for the ICIM circuit is also presented. A batteryless PRF stimulator with ICIM circuit demonstrated good accuracy for the acute measurement of DRG impedance both in situ and in vivo. Besides, an in vivo animal experiment was conducted to show that the effectiveness of pulsed radiofrequency (PRF) stimulation in relieving pain gradually declined as the impedance of the stimulated nerve increased. The experiment also revealed that the excitation voltage for measuring impedance below 25 mV can prevent the excitation of a nonlinear response of DRG.

  11. Skin-electrode impedance measurement during ECG acquisition: method’s validation

    NASA Astrophysics Data System (ADS)

    Casal, Leonardo; La Mura, Guillermo

    2016-04-01

    Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.

  12. Microelectrical Impedance Spectroscopy for the Differentiation between Normal and Cancerous Human Urothelial Cell Lines: Real-Time Electrical Impedance Measurement at an Optimal Frequency

    PubMed Central

    Park, Yangkyu; Kim, Hyeon Woo; Yun, Joho; Seo, Seungwan; Park, Chang-Ju; Lee, Jeong Zoo; Lee, Jong-Hyun

    2016-01-01

    Purpose. To distinguish between normal (SV-HUC-1) and cancerous (TCCSUP) human urothelial cell lines using microelectrical impedance spectroscopy (μEIS). Materials and Methods. Two types of μEIS devices were designed and used in combination to measure the impedance of SV-HUC-1 and TCCSUP cells flowing through the channels of the devices. The first device (μEIS-OF) was designed to determine the optimal frequency at which the impedance of two cell lines is most distinguishable. The μEIS-OF trapped the flowing cells and measured their impedance at a frequency ranging from 5 kHz to 1 MHz. The second device (μEIS-RT) was designed for real-time impedance measurement of the cells at the optimal frequency. The impedance was measured instantaneously as the cells passed the sensing electrodes of μEIS-RT. Results. The optimal frequency, which maximized the average difference of the amplitude and phase angle between the two cell lines (p < 0.001), was determined to be 119 kHz. The real-time impedance of the cell lines was measured at 119 kHz; the two cell lines differed significantly in terms of amplitude and phase angle (p < 0.001). Conclusion. The μEIS-RT can discriminate SV-HUC-1 and TCCSUP cells by measuring the impedance at the optimal frequency determined by the μEIS-OF. PMID:26998490

  13. Investigation of ground reflection and impedance from flyover noise measurements

    NASA Technical Reports Server (NTRS)

    Chapkis, R. L.; Marsh, A. H.

    1978-01-01

    An extensive series of flyover noise tests was conducted for the primary purpose of studying meteorological effects on propagation of aircraft noise. The test airplane, a DC 9-10, flew several level-flight passes at various heights over a taxiway. Two microphone stations were located under the flight path. A total of 37 runs was selected for analysis and processed to obtain a consistant set of 1/3 octave band sound pressure levels at half-second intervals. The goal of the present study was to use the flyover noise data to deduce acoustical reflection coefficients and hence, acoustical impedances.

  14. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

    PubMed

    Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon

    2015-05-01

    The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  15. Circuits and methods for impedance determination using active measurement cancelation

    DOEpatents

    Jamison, David K.

    2016-12-13

    A delta signal and opposite delta signal are generated such that a sum of the two signals is substantially zero. The delta signal is applied across a first set of electrochemical cells. The opposite delta signal is applied across a second set of electrochemical cells series connected to the first set. A first held voltage is established as the voltage across the first set. A second held voltage is established as the voltage across the second set. A first delta signal is added to the first held voltage and applied to the first set. A second delta signal is added to the second held voltage and applied to the second set. The current responses due to the added delta voltages travel only into the set associated with its delta voltage. The delta voltages and the current responses are used to calculate the impedances of their associated cells.

  16. Impedance method for measuring shear elasticity of liquids

    NASA Astrophysics Data System (ADS)

    Badmaev, B. B.; Dembelova, T. S.; Damdinov, B. B.; Gulgenov, Ch. Zh.

    2017-11-01

    Experimental results of studying low-frequency (74 kHz) shear elasticity of polymer liquids by the impedance method (analogous to the Mason method) are presented. A free-volume thick liquid layer is placed on the horizontal surface of a piezoelectric quartz crystal with dimensions 34.7 × 12 × 5.5 cm. The latter performs tangential vibrations at resonance frequency. The liquid layer experiences shear strain, and shear waves should propagate in it. From the theory of the method, it follows that, with an increase in the layer thickness, both real and imaginary resonance frequency shifts should exhibit damped oscillations and tend to limiting values. For the liquids under study, the imaginary frequency shift far exceeds the real one, which testifies to the presence of bulk shear elasticity.

  17. [In vivo measurement of rabbits brain impedance frequency response and the elementary imaging of EIT].

    PubMed

    Wu, Xiaoming; Dong, Xiuzhen; Qin, Mingxin; Fu, Feng; Wang, Yuemin; You, Fusheng; Xiang, Haiyan; Liu, Ruigang; Shi, Xuetao

    2003-03-01

    The in vivo measurements of rabbit brain tissue impedance were taken under both normal and ischemic conditions by using two-electrode measurement method in the frequency range from 0.1 Hz to 1 MHz. The dynamic images about the resistivity of cerebral ischemia were reconstructed based on a 16-electrode system. The results of in vivo measurement showed that the ratio of impedance increased can be as high as 75% at frequencies lower than 10 Hz. In the range from 1 KHz to 1 MHz, the ratio showed a constant value of 15%. The electrical impedance tomography (EIT) images obtained suggested that the regions of impedance changes highly correspond to the position of ischemia. It is confirmed that the brain function changes caused by local deficiency of blood can be detected and imaged by EIT method.

  18. IMPEDANCE MEASUREMENT OF VACUUM CHAMBER COMPONENTS FOR THE ADVANCE PHOTON SOURCE (APS) UPGRADE

    SciTech Connect

    Sangroula, M.; Lindberg, R.; Lill, R.

    2017-06-16

    The proposed Advance Photon Source Upgrade (APS-U) employs a multi-bend achromat (MBA) lattice to increase the photon brightness by two to three orders of magnitude. One of the main design challenges of the upgrade is to minimize rf heating and collective instabilities associated with the impedance of small-aperture vacuum components. As part of this effort, my research focuses on impedance measurement and simulation of various MBA vacuum components. Here, we present the summary of the impedance contributions for the APS-U and describe our planned impedance measurement technique, including some measurement results for the non-evaporative getter (NEG)-coated copper chamber and simulationmore » results for other critical components using a novel Goubau line (G-line) set up.« less

  19. Impedance measurement of vacuum chamber components for the Advance Photon Source(APS) Upgrade

    SciTech Connect

    Sangroula, M.; Lindberg, R.; Lill, R.

    2017-01-01

    The proposed Advance Photon Source Upgrade (APS-U) employs a multi-bend achromat (MBA) lattice to increase the photon brightness by two to three orders of magnitude. One of the main design challenges of the upgrade is to minimize rf heating and collective instabilities associated with the impedance of small-aperture vacuum components. As part of this effort, my research focuses on impedance measurement and simulation of various MBA vacuum components. Here, we present the summary of the impedance contributions for the APS-U and describe our planned impedance measurement technique, including some measurement results for the non-evaporative getter (NEG)-coated copper chamber and simulationmore » results for other critical components using a novel Goubau line (G-line) set up.« less

  20. A novel method for real-time skin impedance measurement during radiofrequency skin tightening treatments.

    PubMed

    Harth, Yoram; Lischinsky, Daniel

    2011-03-01

    The thermal effects of monopolar and bipolar radiofrequency (RF) have been proven to be beneficial in skin tightening. Nevertheless, these effects were frequently partial or unpredictable because of the uncontrolled nature of monopolar or unipolar RF and the superficial nature of energy flow for bipolar or tripolar configurations. One of the hypotheses for lack or predictability of efficacy of the first-generation RF therapy skin tightening systems is lack of adaptation of delivered power to differences in individual skin impedance. A novel multisource phase-controlled system was used (1 MHz, power range 0-65 W) for treatment and real-time skin impedance measurements in 24 patients (EndyMed PRO™; EndyMed, Cesarea, Israel). This system allows continuous real-time measurement of skin impedance delivering constant energy to the patient skin independent of changes in its impedance. More than 6000 unique skin impedance measurements on 22 patients showed an average session impedance range was 215-584 Ohm with an average of 369 Ohm (standard deviation of 49 Ohm). Analyzing individual pulses (total of 600 readings) showed a significant decrease in impedance during the pulse. These findings validate the expected differences in skin impedance between individual patients and in the same patients during the treatment pulse. Clinical study on 30 patients with facial skin aging using the device has shown high predictability of efficacy (86.7% of patients had good results or better at 3 months' follow-up [decrease of 2 or more grades in Fitzpatrick's wrinkle scale]). The real-time customization of energy according to skin impedance allows a significantly more accurate and safe method of nonablative skin tightening with more consistent and predictable results. © 2011 Wiley Periodicals, Inc.

  1. Experimental investigation of microwave interaction with magnetoplasma in miniature multipolar configuration using impedance measurements

    SciTech Connect

    Dey, Indranuj, E-mail: indranuj@aees.kyushu-u.ac.jp; Toyoda, Yuji; Yamamoto, Naoji

    2014-09-15

    A miniature microwave plasma source employing both radial and axial magnetic fields for plasma confinement has been developed for micro-propulsion applications. Plasma is initiated by launching microwaves via a short monopole antenna to circumvent geometrical cutoff limitations. The amplitude and phase of the forward and reflected microwave power is measured to obtain the complex reflection coefficient from which the equivalent impedance of the plasma source is determined. Effect of critical plasma density condition is reflected in the measurements and provides insight into the working of the miniature plasma source. A basic impedance calculation model is developed to help in understandingmore » the experimental observations. From experiment and theory, it is seen that the equivalent impedance magnitude is controlled by the coaxial discharge boundary conditions, and the phase is influenced primarily by the plasma immersed antenna impedance.« less

  2. Static and Dynamic Measurement of Dopamine Adsorption in Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.

    PubMed

    Rivera-Serrano, Nilka; Pagan, Miraida; Colón-Rodríguez, Joanisse; Fuster, Christian; Vélez, Román; Almodovar-Faria, Jose; Jiménez-Rivera, Carlos; Cunci, Lisandro

    2018-02-06

    In this study, electrochemical impedance spectroscopy was used for the first time to study the adsorption of dopamine in carbon fiber microelectrodes. In order to show a proof-of-concept, static and dynamic measurements were taken at potentials ranging from -0.4 to 0.8 V versus Ag|AgCl to demonstrate the versatility of this technique to study dopamine without the need of its oxidation. We used electrochemical impedance spectroscopy and single frequency electrochemical impedance to measure different concentrations of dopamine as low as 1 nM. Moreover, the capacitance of the microelectrodes surface was found to decrease due to dopamine adsorption, which is dependent on its concentration. The effect of dissolved oxygen and electrochemical oxidation of the surface in the detection of dopamine was also studied. Nonoxidized and oxidized carbon fiber microelectrodes were prepared and characterized by optical microscopy, scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Optimum working parameters of the electrodes, such as frequency and voltage, were obtained for better measurement. Electrochemical impedance of dopamine was determined at different concentration, voltages, and frequencies. Finally, dynamic experiments were conducted using a flow cell and single frequency impedance in order to study continuous and real-time measurements of dopamine.

  3. Drilling electrode for real-time measurement of electrical impedance in bone tissues.

    PubMed

    Dai, Yu; Xue, Yuan; Zhang, Jianxun

    2014-03-01

    In order to prevent possible damages to soft tissues, reliable monitoring methods are required to provide valuable information on the condition of the bone being cut. This paper describes the design of an electrical impedance sensing drill developed to estimate the relative position between the drill and the bone being drilled. The two-electrode method is applied to continuously measure the electrical impedance during a drill feeding movement: two copper wire brushes are used to conduct electricity in the rotating drill and then the drill is one electrode; a needle is inserted into the soft tissues adjacent to the bone being drilled and acts as another electrode. Considering that the recorded electrical impedance is correlated with the insertion depth of the drill, we theoretically calculate the electrode-tissue contact impedance and prove that the rate of impedance change varies considerably when the drill bit crosses the boundary between two different bone tissues. Therefore, the rate of impedance change is used to determine whether the tip of the drill is located in one of cortical bone, cancellous bone, and cortical bone near a boundary with soft tissue. In vitro experiments in porcine thoracic spines were performed to demonstrate the feasibility of the impedance sensing drill. The experimental results indicate that the drill, used with the proposed data-processing method, can provide accurate and reliable breakthrough detection in the bone-drilling process.

  4. Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue

    NASA Astrophysics Data System (ADS)

    Ikhsanti, Mila Izzatul; Bouzida, Rana; Wijaya, Sastra Kusuma; Rohmadi, Muttakin, Imamul; Taruno, Warsito P.

    2017-02-01

    This research aims to explore the feasibility of capacitance-digital converter and impedance converter for measurement module in electrical capacitance tomography (ECT) system. ECT sensor used was a cylindrical sensor having 8 electrodes. Absolute capacitance measurement system based on Sigma Delta Capacitance-to-Digital-Converter AD7746 has been shown to produce measurement with high resolution. Whereas, capacitance measurement with wide range of frequency is possible using Impedance Converter AD5933. Comparison of measurement accuracy by both AD7746 and AD5933 with reference of LCR meter was evaluated. Biological matters represented in water and oil were treated as object reconstructed into image using linear back projection (LBP) algorithm.

  5. Impedance computations and beam-based measurements: A problem of discrepancy

    SciTech Connect

    Smaluk, Victor

    High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictionsmore » based on the computed impedance budgets show a significant discrepancy. For this article, three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.« less

  6. Impedance computations and beam-based measurements: A problem of discrepancy

    DOE PAGES

    Smaluk, Victor

    2018-04-21

    High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictionsmore » based on the computed impedance budgets show a significant discrepancy. For this article, three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.« less

  7. Impedance computations and beam-based measurements: A problem of discrepancy

    NASA Astrophysics Data System (ADS)

    Smaluk, Victor

    2018-04-01

    High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictions based on the computed impedance budgets show a significant discrepancy. Three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.

  8. On the use of The Bio-Impedance technique for Body Composition Measurements

    NASA Astrophysics Data System (ADS)

    Huerta-Franco, R.; Vargas-Luna, M.; González-Solís, J. L.; Gutiérrez-Juárez, G.

    2003-09-01

    Reviewing the methods and physical principles used in body composition measurements (BCM), it is evident that more accurate, reliable, and easily handled methods are required. The use of bio-impedance analysis (BIA) has been very useful in BCM. This technique, in the single frequency mode, has some commercial versions to perform BCM. However these apparatus have significant variability in the BCM values. The multi-frequency option of the bio-impedance technique has still a lot of challenges to overcome. We studied the variability of the body impedance spectrum (from 1 Hz to 1 MHz) in a group of subjects compared to the values obtained from commercial apparatus. We compared different anatomical body regions, some of them with less subcutaneous body fat (frontal, anterior tibial, knee, and frontal regions); others with more subcutaneous body fat (pectoral, abdominal, and internal calf regions). In order to model the bio-impedance spectrum, we analyzed layered samples with different thickness and material composition.

  9. Measuring the multi-frequency electrical impedance of the mouse gastrocnemius muscle using a tetrapolar technique

    NASA Astrophysics Data System (ADS)

    Li, J.; Fogerson, P. M.; Rutkove, S. B.

    2010-04-01

    Electrical impedance methods can be used to evaluate and monitor neuromuscular disease states. Recently, we have applied tetrapolar surface electrical impedance methods to the gastrocnemius muscle of the rat for this purpose and substantial changes in the impedance parameters after sciatic nerve crush can be identified. In order to be able to study additional animal models of nerve and muscle disease, however, it would highly desirable to be able to perform such impedance measurements in the mouse. Yet the small size of the mouse presents a substantial technical challenge. In this study, we evaluate a basic approach for performing such measurements. A series of thin, stainless steel strip electrodes affixed to the gastrocnemius and interfaced via a separate connector to the Imp SFB7® (Impedimed, Inc), provided an effective means for obtaining impedance data in the 20-500 kHz range. After two weeks, test-retest reproducibility was good, with intra-class correlation coefficients as high 0.84 and variability as low as 12.86 ± 6.18% in the 15 mice studied. Using this approach, it may now be possible to study impedance changes in a variety of mouse models of neuromuscular disease, including amyotrophic lateral sclerosis, spinal muscular atrophy, muscular dystrophy and Charcot-Marie-Tooth disease.

  10. Portable bioimpedance monitor evaluation for continuous impedance measurements. Towards wearable plethysmography applications.

    PubMed

    Ferreira, J; Seoane, F; Lindecrantz, K

    2013-01-01

    Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.

  11. Measurements of high impedance two-terminal device with SMU NI PXIe-4139

    NASA Astrophysics Data System (ADS)

    Bogdanov, S. V.; Lelekov, E. T.; Kovalev, I. V.; Zelenkov, P. V.; Lelekov, A. T.

    2016-11-01

    To measure high-frequency and low-frequency impedance of betavoltaic power sources (it can be represented as two-terminal device), measurement stand was created. To measure high-frequency part need to inject external test signal through the current transformer with waveform generator and need to use external high-frequency current sensor, because of SMU PXIe-4139 current channel limitations.

  12. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    PubMed

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  13. Inductance analyzer based on auto-balanced circuit for precision measurement of fluxgate impedance

    NASA Astrophysics Data System (ADS)

    Setiadi, Rahmondia N.; Schilling, Meinhard

    2018-05-01

    An instrument for fluxgate sensor impedance measurement based on an auto-balanced circuit has been designed and characterized. The circuit design is adjusted to comply with the fluxgate sensor characteristics which are low impedance and highly saturable core with very high permeability. The system utilizes a NI-DAQ card and LabVIEW to process the signal acquisition and evaluation. Some fixed reference resistances are employed for system calibration using linear regression. A multimeter HP 34401A and impedance analyzer Agilent 4294A are used as calibrator and validator for the resistance and inductance measurements. Here, we realized a fluxgate analyzer instrument based on auto-balanced circuit, which measures the resistance and inductance of the device under test with a small error and much lower excitation current to avoid core saturation compared to the used calibrator.

  14. Crew Quarters (CQ) and Electromagnetic Interference (EMI) Measurement Facility Combined Impedance Study

    NASA Technical Reports Server (NTRS)

    Scully, Robert C.

    2011-01-01

    This report documents an investigation into observed failures associated with conducted susceptibility testing of Crew Quarters (CQ) hardware in the Johnson Space Center (JSC) Electromagnetic Interference (EMI) Measurement Facility, and the work accomplished to identify the source of the observed behavior. Investigation led to the conclusion that the hardware power input impedance was interacting with the facility power impedance leading to instability at the observed frequencies of susceptibility. Testing performed in other facilities did not show this same behavior, pointing back to the EMI Measurement Facility power as the potential root cause. A LISN emulating the Station power bus impedance was inserted into the power circuit, and the susceptibility was eliminated from the measurements.

  15. The development of the miniaturized waveform receiver with the function measuring Antenna Impedance in space plasmas

    NASA Astrophysics Data System (ADS)

    Ishii, H.; Kojima, H.; Fukuhara, H.; Okada, S.; Yamakawa, H.

    2012-04-01

    Plasma wave is one of the most essential physical quantities in the solar terrestrial physics. The role of plasma wave receiver onboard satellites is to detect plasma waves in space with a good signal to noise ratio. There are two types of plasma wave receivers, the sweep frequency analyzer and the waveform capture. While the sweep frequency analyzer provides plasma wave spectra, the waveform capture obtains waveforms with phase information that is significant in studying nonlinear phenomena. Antenna sensors to observe electric fields of the plasma waves show different features in plasmas from in vacuum. The antenna impedances have specific characteristics in the frequency domain because of the dispersion of plasmas. These antenna impedances are expressed with complex number. We need to know not only the antenna impedances but also the transfer functions of plasma wave receiver's circuits in order to calibrate observed waveforms precisely. The impedances of the electric field antennas are affected by a state of surrounding plasmas. Since satellites run through various regions with different plasma parameters, we precisely should measure the antenna impedances onboard spacecraft. On the contrary, we can obtain the plasma density and by measuring the antenna impedances. Several formulas of the antenna impedance measurement system were proposed. A synchronous detection method is used on the BepiColombo Mercury Magnetospheric Orbiter (MMO), which will be launched in 2014. The digital data are stored in the onboard memory. They are read out and converted to the analog waveforms by D/A converter. They are fed into the input of the preamplifiers of antenna sensors through a resistor. We can calculate a transfer function of the circuit by applying the synchronous detection method to the output waveform from waveform receivers and digital data as a signal source. The size of this system is same as an A5 board. In recent years, Application Specific Integrated Circuit (ASIC

  16. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

    PubMed

    Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D

    2001-10-01

    The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

  17. Studies of longitudinal profile of electron bunches and impedance measurements at Indus-2 synchrotron radiation source

    NASA Astrophysics Data System (ADS)

    Garg, Akash Deep; Yadav, S.; Kumar, Mukesh; Shrivastava, B. B.; Karnewar, A. K.; Ojha, A.; Puntambekar, T. A.

    2016-04-01

    Indus-2 is a 3rd generation synchrotron radiation source at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We study the longitudinal profile of electrons in Indus-2 by using dual sweep synchroscan streak camera at visible diagnostic beamline. In this paper, the longitudinal profiles of electron bunch are analyzed by filling beam current in a single bunch mode. These studies are carried at injection energy (550 MeV) and at ramped beam energy (2.5 GeV). The effects of the wakefield generated interactions between the circulating electrons and the surrounding vacuum chamber are analyzed in terms of measured effects on longitudinal beam distribution. The impedance of the storage ring is obtained by fitting the solutions of Haissinski equation to the measured bunch lengthening with different impedance models. The impedance of storage ring obtained by a series R+L impedance model indicates a resistance (R) of 1350±125 Ω, an inductance (L) of 180±25 nH and broadband impedance of 2.69 Ω. These results are also compared with the values obtained from measured synchronous phase advancing and scaling laws. These studies are very useful in better understanding and control of the electromagnetic interactions.

  18. In-Plane Impedance Spectroscopy measurements in Vanadium Dioxide thin films

    NASA Astrophysics Data System (ADS)

    Ramirez, Juan; Patino, Edgar; Schmidt, Rainer; Sharoni, Amos; Gomez, Maria; Schuller, Ivan

    2012-02-01

    In plane Impedance Spectroscopy measurements have been done in Vanadium Dioxide thin films in the range of 100 Hz to 1 MHz. Our measurements allows distinguishing between the resistive and capacitive response of the Vanadium Dioxide films across the metal-insulator transition. A non ideal RC behavior was found in our thin films from room temperature up to 334 K. Around the MIT, an increase of the total capacitance is observed. A capacitor-network model is able to reproduce the capacitance changes across the MIT. Above the MIT, the system behaves like a metal as expected, and a modified equivalent circuit is necessary to describe the impedance data adequately.

  19. Comparison of different coil positions for ventilation monitoring with contact-less magnetic impedance measurements

    NASA Astrophysics Data System (ADS)

    Cordes, A.; Pollig, D.; Leonhardt, S.

    2010-04-01

    For monitoring the health status of individuals, proper monitoring of ventilation is desirable. Therefore, a continuous measurement technique is an advantage for many patients since it allows personal home care scenarios. As an example, monitoring of elderly people at home could enable them to live in their familiar environment on their own with the safety of a continuous monitoring. Therefore, a measurement technique without the restriction of mobility is required. Since it is possible to monitor ventilation with magnetic impedance measurements without conductive contact, this technique is well suited for the mentioned scenario. Integrated in a chair, a person's health state could be monitored in many situations, e.g. during meals, while watching TV or reading a book. In this paper, we compare different positions of coil arrays for a magnetic impedance measurement system integrated in a chair in order to monitor ventilation continuously. For limiting the costs and technical complexity of the magnetic impedance measurement system, we have a focus on coil configurations with one RF channel. To limit the needed space and thickness of the array in the backrest, planar gradiometer coil setups are investigated. All measurements will be performed with a new developed portable magnetic impedance measurement system and a standard office chair.

  20. Impedance spectroscopy measurements as a tool for distinguishing different luminal content during bolus transit studies.

    PubMed

    Ruiz-Vargas, A; Mohd Rosli, R; Ivorra, A; Arkwright, J W

    2018-01-08

    Intraluminal electrical impedance is a well-known diagnostic tool used to study bolus movement in the human esophagus. However, it is use in the human colon it is hindered by the fact that the content cannot be controlled and may include liquid, gas, solid, or a mixture of these at any one time. This article investigates the use of complex impedance spectroscopy to study different luminal content (liquid and gas). An excised section of guinea pig proximal colon was placed in an organ bath with Krebs solution at 37°C and a custom built bioimpedance catheter was placed in the lumen. Liquid (Krebs) and gas (air) content was pumped through the lumen and the intraluminal impedance was measured at five different frequencies (1, 5.6, 31.6, 177.18 kHz and 1 MHz) at 10 samples per second. A numerical model was created to model the passage of bolus with different content and compared to the experimental data. Differences in mean impedance magnitude and phase angle were found (from 1 to 177.18 kHz) for different contents. The numerical results qualitatively agreed with those in the experimental study. Conductivities of bolus had an effect on detecting its passage. Complex impedance spectroscopy can distinguish between different luminal content within a range of measuring frequencies. The numerical model showed the importance of bolus conductivities for bolus transit studies in those where the bolus is controlled. © 2018 John Wiley & Sons Ltd.

  1. Impedance probe to measure local void fraction profiles

    NASA Astrophysics Data System (ADS)

    Teyssedou, A.; Tapucu, A.; Lortie, M.

    1988-04-01

    A conductivity-type local void measurement system has been developed. The effects of the sensor tip geometry, the unbalance of the front-end bridge, the comparator threshold level, and the mass fluxes on the response of the instrument have been studied. The system has been calibrated under air-water two-phase flow conditions using the quick-closing-valve technique. Comparison of the void profiles obtained with the conductivity probe with those obtained using an optical probe confirms the applicability of this system for two-phase (air-water) flows.

  2. Lorentz force electrical impedance tomography using magnetic field measurements.

    PubMed

    Zengin, Reyhan; Gençer, Nevzat Güneri

    2016-08-21

    In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic wave propagates along its path. The forward problem of this imaging modality is defined as calculation of the pick-up voltages due to a given acoustic excitation and known body properties. Firstly, the feasibility of the proposed technique is investigated analytically. The basic field equations governing the behaviour of time-varying electromagnetic fields are presented. Secondly, the general formulation of the partial differential equations for the scalar and magnetic vector potentials are derived. To investigate the feasibility of this technique, numerical studies are conducted using a finite element method based software. To sense the pick-up voltages a novel coil configuration (xy coil pairs) is proposed. Two-dimensional numerical geometry with a 16-element linear phased array (LPA) ultrasonic transducer (1 MHz) and a conductive body (breast fat) with five tumorous tissues is modeled. The static magnetic field is assumed to be 4 Tesla. To understand the performance of the imaging system, the sensitivity matrix is analyzed. The sensitivity matrix is obtained for two different locations of LPA transducer with eleven steering angles from [Formula: see text] to [Formula: see text] at intervals of [Formula: see text]. The characteristics of the imaging system are shown with the singular value decomposition (SVD) of the sensitivity matrix. The images are reconstructed with the truncated SVD algorithm. The signal-to-noise ratio in measurements is assumed 80 d

  3. Lorentz force electrical impedance tomography using magnetic field measurements

    NASA Astrophysics Data System (ADS)

    Zengin, Reyhan; Güneri Gençer, Nevzat

    2016-08-01

    In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic wave propagates along its path. The forward problem of this imaging modality is defined as calculation of the pick-up voltages due to a given acoustic excitation and known body properties. Firstly, the feasibility of the proposed technique is investigated analytically. The basic field equations governing the behaviour of time-varying electromagnetic fields are presented. Secondly, the general formulation of the partial differential equations for the scalar and magnetic vector potentials are derived. To investigate the feasibility of this technique, numerical studies are conducted using a finite element method based software. To sense the pick-up voltages a novel coil configuration (xy coil pairs) is proposed. Two-dimensional numerical geometry with a 16-element linear phased array (LPA) ultrasonic transducer (1 MHz) and a conductive body (breast fat) with five tumorous tissues is modeled. The static magnetic field is assumed to be 4 Tesla. To understand the performance of the imaging system, the sensitivity matrix is analyzed. The sensitivity matrix is obtained for two different locations of LPA transducer with eleven steering angles from -{{25}\\circ} to {{25}\\circ} at intervals of {{5}\\circ} . The characteristics of the imaging system are shown with the singular value decomposition (SVD) of the sensitivity matrix. The images are reconstructed with the truncated SVD algorithm. The signal-to-noise ratio in measurements is assumed 80 dB. Simulation studies

  4. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery

    PubMed Central

    Aglzim, El-Hassane; Rouane, Amar; El-Moznine, Reddad

    2007-01-01

    In this paper we present an inexpensive electronic measurement instrumentation developed in our laboratory, to measure and plot the impedance of a loaded fuel cell or battery. Impedance measurements were taken by using the load modulation method. This instrumentation has been developed around a VXI system stand which controls electronic cards. Software under Hpvee® was developed for automatic measurements and the layout of the impedance of the fuel cell on load. The measurement environment, like the ambient temperature, the fuel cell temperature, the level of the hydrogen, etc…, were taken with several sensors that enable us to control the measurement. To filter the noise and the influence of the 50Hz, we have implemented a synchronous detection which filters in a very narrow way around the useful signal. The theoretical result obtained by a simulation under Pspice® of the method used consolidates the choice of this method and the possibility of obtaining correct and exploitable results. The experimental results are preliminary results on a 12V vehicle battery, having an inrush current of 330A and a capacity of 40Ah (impedance measurements on a fuel cell are in progress, and will be the subject of a forthcoming paper). The results were plotted at various nominal voltages of the battery (12.7V, 10V, 8V and 5V) and with two imposed currents (0.6A and 4A). The Nyquist diagram resulting from the experimental data enable us to show an influence of the load of the battery on its internal impedance. The similitude in the graph form and in order of magnitude of the values obtained (both theoretical and practical) enables us to validate our electronic measurement instrumentation. One of the future uses for this instrumentation is to integrate it with several control sensors, on a vehicle as an embedded system to monitor the degradation of fuel cell membranes. PMID:28903231

  5. Assessment of lamb carcass composition from live animal measurement of bioelectrical impedance or ultrasonic tissue depths.

    PubMed

    Berg, E P; Neary, M K; Forrest, J C; Thomas, D L; Kauffman, R G

    1996-11-01

    Market weight lambs, average weight 52.5 kg (+/-6.1), were used to evaluate nontraditional live animal measurements as predictors of carcass composition. The sample population (n = 106) represented U.S. market lambs and transcended geographic location, breed, carcass weight, yield grade, and production system. Realtime ultrasonic (RU) measurements and bioelectrical impedance analysis (BIA) were used for development and evaluation of prediction equations for % boneless, closely trimmed primal cuts (BCTPC), weight or % of dissected lean tissue (TDL), and chemically derived weight or % fat-free lean (FFL). Longitudinal ultrasonic images were obtained parallel to the longissimus thoracis et lumborum (LTL), positioning the last costae in the center of the transducer head. Images were saved and fat and LTL depths were derived from printed images of the ultrasonic scans. Bioelectrical impedance analysis was administered via a four-terminal impedance plethysmograph operating at 800 microA at 50 kHz. Impedance measurements of whole-body resistance and reactance were recorded. Prediction equations including common linear measurements of live weight, heart girth, hindsaddle length, and shoulder height were also evaluated. All measurements were taken just before slaughter. Bioelectrical impedance measurements (as compared to RU and linear measurements) provided equations for %BCTPC, TDL, %TDL, FFL and %FFL with the highest R2 and lowest root mean square error. Even though BIA provided the best equations of the three methodologies tested, prediction of proportional yield (%BCTPC, %TDL, and %FFL) was marginal (R2 = .296, .551, and .551, respectively). Equations combining BIA, RU, and linear measurements greatly improved equations for prediction of proportional lean yield.

  6. [A Digital System for Bioimpedance and Electrical Impedance Tomography Measurement System].

    PubMed

    Chen, Xiaoyan; Gao, Nana; Huang, Huafang

    2015-06-01

    A digital system for bioimpedance and electrical impedance tomography (EIT) measurement controlled by an ATmega16 microcontroller was constructed in our laboratory. There are eight digital electrodes using AD5933 to measure the impedance of the targets, and the data is transmitted to the computer wirelessly through nRF24L01. The structure of the system, circuit design, system testing, vitro measurements of animals' tissues and electrical impedance tomography are introduced specifically in this paper. The experimental results showed that the system relative error was 0.42%, and the signal noise ratio was 76.3 dB. The system not only can be used to measure the impedance by any two electrodes within the frequency of 1-100 kHz in a sweep scanning, but also can reconstruct the images of EIT. The animal experiments showed that the data was valid and plots were fitting with Cole-Cole theory. The testing verified the feasibility and effectiveness of the system. The images reconstructed of a salt-water tank are satisfactory and match with the actual distribution of the tank. The system improves the effectiveness of the front-end measuring signal and the stability of the system greatly.

  7. Tissue electrical properties measured by bioelectrical impedance analysis among healthy and sportsmen population

    NASA Astrophysics Data System (ADS)

    Kapica, Dominik; Warchulińska, Joanna; Jakubiak, Monika; Teter, Mariusz; Mlak, Radosław; Hałabiś, Magdalena; Wójcik, Waldemar; Małecka-Massalska, Teresa

    2015-09-01

    Introduction: Bioelectrical impedance analysis (BIA) is a useful tool to asses human body composition and nutrition status; multi-frequency BIA has a higher accuracy than single-frequency BIA. In our study a difference of impedance values (Z) at 5, 100 and 200 kHz and Z200/Z5 index between professional athletes and control group were determined. Methods: In this research 105 people were tested, divided into control group (72 people: 35 males and 37 females) and professional athletes (33 people: 16 males and 17 females). Impedance was measured at three frequency values - 5, 100 and 200 kHz; with received values the Z200/Z5 index was calculated. Results: In most compared subgroups impedance values showed significantly lower values in athletes than in control group (5 kHz - males: p=0.136, females: p=0.001, 100 kHz - males: p=0.039, females: p<0.0001, 200 kHz - males: p=0.047, females: p<0.0001) Z200/Z5 index also showed lower value in athletes than in control group (p=0.016 for males, p<0.0001 for females). Conclusion: Lower values of impedance and Z200/Z5 index indicates a better nutrition status and general health condition of athletes than in control group.

  8. Tissue type determination by impedance measurement: A bipolar and monopolar comparison

    PubMed Central

    Sharp, Jack; Bouazza-Marouf, Kaddour; Noronha, Dorita; Gaur, Atul

    2017-01-01

    Background: In certain medical applications, it is necessary to be able to determine the position of a needle inside the body, specifically with regards to identifying certain tissue types. By measuring the electrical impedance of specific tissue types, it is possible to determine the type of tissue the tip of the needle (or probe) is at. Materials and Methods: Two methods have been investigated for electric impedance detection; bipolar and monopolar. Commercially available needle electrodes are of a monopolar type. Although many patents exist on the bipolar setups, these have not as yet been commercialized. This paper reports a comparison of monopolar and bipolar setups for tissue type determination. In vitro experiments were carried out on pork to compare this investigation with other investigations in this field. Results: The results show that both monopolar and bipolar setups are capable of determining tissue type. However, the bipolar setup showed slightly better results; the difference between the different soft tissue type impedances was greater compared to the monopolar method. Conclusion: Both monopolar and bipolar electrical impedance setups work very similarly in inhomogeneous volumes such as biological tissue. There is a clear potential for clinical applications with impedance-based needle guidance, with both the monopolar and bipolar setups. It is, however, worth noting that the bipolar setup is more versatile. PMID:28217047

  9. Electrode-Skin contact impedance: In vivo measurements on an ovine model

    NASA Astrophysics Data System (ADS)

    Nguyen, D. T.; Kosobrodov, R.; Barry, M. A.; Chik, W.; Jin, C.; Oh, T. I.; Thiagalingam, A.; McEwan, A.

    2013-04-01

    The problem of electrical impedance between the skin and the electrode is an on-going challenge in bio-electronics. This is particularly true in the case of Electrical Impedance Tomography (EIT), which uses a large number of skin-contact electrodes and is very sensitive to noise. In the present article, contact impedance is measured and compared for a range of electrodes placed on the thorax of an ovine model. The study has been approved by the Westmead Hospital Animal Ethics Committee. The electrode models that were employed in the research are Ag/AgCl electrodes (E1), commonly used for ECG and EIT measurements in both humans and animal models, stainless steel crocodile clips (E2), typically used on animal models, and novel multi-point dry electrodes in two modifications: bronze plated (E3) and nickel plated (E4). Further, since the contact impedance is mostly attributed to the acellular outer layer of the skin, in our experiment, we attempted to study the effect of this layer by comparing the results when the skin is intact and when electrodes are introduced underneath the skin through small cuts. This boundary effect was assessed by comparison of measurements obtained during E2 skin surface contact, and sub-cutaneous contact (E5). Twelve gauge intradermal needles were also tested as an electrode (E6). The full impedance spectrum, from 500 Hz to 300 kHz, was recorded, analysed and compared. As expected, the contact impedance in the more invasive cases, i.e the electrodes under the skin, is significantly lower than in the non-invasive cases. At the frequency of 50 kHz which is commonly used in lung EIT acquisition, electrodes E3, E4 and E6 demonstrated contact impedance of less than 200 Ω, compared to more than 400 Ω measured for electrodes E1, E2 and E5. In conclusion, the novel multipoint electrodes proved to be best suited for EIT purposes, because they are non-invasive and have lower contact impedance than Ag/AgCl and crocodile clips, in both invasive and

  10. Measurements of acoustic impedance at the input to the occluded ear canal.

    PubMed

    Larson, V D; Nelson, J A; Cooper, W A; Egolf, D P

    1993-01-01

    Multi-frequency (multi-component) acoustic impedance measurements may evolve into a sensitive technique for the remote detection of aural pathologies. Such data are also relevant to models used in hearing aid design and could be an asset to the hearing aid prescription and fitting process. This report describes the development and use of a broad-band procedure which acquires impedance data in 20 Hz intervals and describes a comparison of data collected at two sites by different investigators. Mean data were in excellent agreement, and an explanation for a single case of extreme normal variability is presented.

  11. Development of high impedance measurement system for water leakage detection in implantable neuroprosthetic devices.

    PubMed

    Yousif, Aziz; Kelly, Shawn K

    2016-08-01

    There has been a push for a greater number of channels in implantable neuroprosthetic devices; but, that number has largely been limited by current hermetic packaging technology. Microfabricated packaging is becoming reality, but a standard testing system is needed to prepare these devices for clinical trials. Impedance measurements of electrodes built into the packaging layers may give an early warning of device failure and predict device lifetime. Because the impedance magnitudes of such devices can be on the order of gigaohms, a versatile system was designed to accommodate ultra-high impedances and allow future integrated circuit implementation in current neural prosthetic technologies. Here we present the circuitry, control software, and preliminary testing results of our designed system.

  12. Estimating body fat by using bioelectrical-impedance measurements: a preliminary assessment.

    Treesearch

    M.G. Raphael; H.J. Harlow; S.W. Buskirk

    1991-01-01

    We evaluated a technique for measuring body fat content of marten (Martes americana) by using a noninvasive bioelectrical-impedance device with four electrodes to introduce a current into the body. Instantaneous readings of resistance were significantly correlated with fat-free mass (determined from solvent extraction) of carcasses of 17 skinned (r...

  13. Servo-controlled pneumatic pressure oscillator for respiratory impedance measurements and high-frequency ventilation.

    PubMed

    Kaczka, David W; Lutchen, Kenneth R

    2004-04-01

    The ability to provide forced oscillatory excitation of the respiratory system can be useful in mechanical impedance measurements as well as high frequency ventilation (HFV). Experimental systems currently used for generating forced oscillations are limited in their ability to provide high amplitude flows or maintain the respiratory system at a constant mean pressure during excitation. This paper presents the design and implementation of a pneumatic pressure oscillator based on a proportional solenoid valve. The device is capable of providing forced oscillatory excitations to the respiratory system over a bandwidth suitable for mechanical impedance measurements and HVF. It delivers high amplitude flows (> 1.4 l/s) and utilizes a servo-control mechanism to maintain a load at a fixed mean pressure during simultaneous oscillation. Under open-loop conditions, the device exhibited a static hysteresis of approximately 7%, while its dynamic magnitude and phase responses were flat out to 10 Hz. Broad-band measurement of total harmonic distortion was approximately 19%. Under closed-loop conditions, the oscillator was able to maintain a mechanical test load at both positive and negative mean pressures during oscillatory excitations from 0.1 to 10.0 Hz. Impedance of the test load agreed closely with theoretical predictions. We conclude that this servo-controlled oscillator can be a useful tool for respiratory impedance measurements as well as HFV.

  14. Method and device for bio-impedance measurement with hard-tissue applications.

    PubMed

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-06-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kOmega to 10 MOmega across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kOmega to 10 MOmega and from 20 pF to 100 pF, are discussed.

  15. Estimation of pressure-particle velocity impedance measurement uncertainty using the Monte Carlo method.

    PubMed

    Brandão, Eric; Flesch, Rodolfo C C; Lenzi, Arcanjo; Flesch, Carlos A

    2011-07-01

    The pressure-particle velocity (PU) impedance measurement technique is an experimental method used to measure the surface impedance and the absorption coefficient of acoustic samples in situ or under free-field conditions. In this paper, the measurement uncertainty of the the absorption coefficient determined using the PU technique is explored applying the Monte Carlo method. It is shown that because of the uncertainty, it is particularly difficult to measure samples with low absorption and that difficulties associated with the localization of the acoustic centers of the sound source and the PU sensor affect the quality of the measurement roughly to the same extent as the errors in the transfer function between pressure and particle velocity do. © 2011 Acoustical Society of America

  16. Impedance measurements of the extraction kicker system for the rapid cycling synchrotron of China Spallation Neutron Source

    NASA Astrophysics Data System (ADS)

    Huang, Liang-Sheng; Wang, Sheng; Liu, Yu-Dong; Li, Yong; Liu, Ren-Hong; Xiao, Ou-Zheng

    2016-04-01

    The fast extraction kicker system is one of the most important accelerator components and the main source of impedance in the Rapid Cycling Synchrotron of the China Spallation Neutron Source. It is necessary to understand the kicker impedance before its installation into the tunnel. Conventional and improved wire methods are employed in the impedance measurement. The experimental results for the kicker impedance are explained by comparison with simulation using CST PARTICLE STUDIO. The simulation and measurement results confirm that the window-frame ferrite geometry and the end plate are the important structures causing coupling impedance. It is proved in the measurements that the mismatching from the power form network to the kicker leads to a serious oscillation sideband of the longitudinal and vertical impedance and the oscillation can be reduced by ferrite absorbing material. Supported by National Natural Science Foundation of China (11175193, 11275221)

  17. Beam measurement of the high frequency impedance sources with long bunches in the CERN Super Proton Synchrotron

    NASA Astrophysics Data System (ADS)

    Lasheen, A.; Argyropoulos, T.; Bohl, T.; Esteban Müller, J. F.; Timko, H.; Shaposhnikova, E.

    2018-03-01

    Microwave instability in the Super Proton Synchrotron (SPS) at CERN is one of the main limitations to reach the requirements for the High Luminosity-LHC project (increased beam intensity by a factor 2). To identify the impedance source responsible of the instability, beam measurements were carried out to probe the SPS impedance. The method presented in this paper relies on measurements of the unstable spectra of single bunches, injected in the SPS with the rf voltage switched off. The modulation of the bunch profile gives information about the main impedance sources driving microwave instability, and is compared to particle simulations using the SPS impedance model to identify the most important contributions. This allowed us to identify the vacuum flanges as the main impedance source for microwave instability in the SPS, and to evaluate possible missing impedance sources.

  18. Validity and reproducibility of electrical impedance tomography for measurement of calf blood flow in healthy subjects.

    PubMed

    Vonk Noordegraaf, A; Kunst, P W; Janse, A; Smulders, R A; Heethaar, R M; Postmus, P E; Faes, T J; de Vries, P M

    1997-03-01

    The Sheffield electrical impedance tomography; (EIT) system produces images of changes in the distribution of resistivity within tissue. The paper reports on the application of electrical impedance tomography in monitoring volume changes in the limb during venous occlusion. The aim of the study is to assess the feasibility, reproducibility and validity of calf blood flow measurements by EIT. In 14 healthy volunteers calf blood flow is compared, as determined in a calf segment by strain-gauge plethysmography (SGP), with the impedance changes measured by EIT during rest and post-ischaemic hyperaemia. The measurements are repeated to assess reproducibility. The reproducibility for the EIT, assessed from the repeated measurements and expressed as a reproducibility coefficient, is 0.88 during rest and 0.89 during hyperaemia. The reproducibility coefficient for SGP data is 0.83 at rest and 0.67 during hyperaemia. Flow measurements, assessed by means of two methods, correlate well at rest (r = 0.89), but only moderately during hyperaemia (r = 0.51). The correlation coefficient for the pooled flow measurements is 0.98. It is concluded that EIT is a valid and reliable method for assessing blood flow in the limb. Possible applications of EIT in localising fluid changes are discussed.

  19. Abdominal fat thickness measurement using Focused Impedance Method (FIM) - phantom study

    NASA Astrophysics Data System (ADS)

    Haowlader, Salahuddin; Baig, Tanveer Noor; Siddique-e Rabbani, K.

    2010-04-01

    Abdominal fat thickness is a risk indicator of heart diseases, diabetes, etc., and its measurement is therefore important from the point of view of preventive care. Tetrapolar electrical impedance measurements (TPIM) could offer a simple and low cost alternative for such measurement compared to conventional techniques using CT scan and MRI, and has been tried by different groups. Focused Impedance Method (FIM) appears attractive as it can give localised information. An intuitive physical model was developed and experimental work was performed on a phantom designed to simulate abdominal subcutaneous fat layer in a body. TPIM measurements were performed with varying electrode separations. For small separations of current and potential electrodes, the measured impedance changed little, but started to decrease sharply beyond a certain separation, eventually diminishing gradually to negligible values. The finding could be explained using the intuitive physical model and gives an important practical information. TPIM and FIM may be useful for measurement of SFL thickness only if the electrode separations are within a certain specific range, and will fail to give reliable results if beyond this range. Further work, both analytical and experimental, are needed to establish this technique on a sound footing.

  20. Calculating realistic voltages across the US power grid utilizing measured impedances and magnetic fields

    NASA Astrophysics Data System (ADS)

    Lucas, G.; Love, J. J.; Kelbert, A.; Bedrosian, P.; Rigler, E. J.

    2017-12-01

    Space weather induces significant geoelectric fields within Earth's subsurface that can adversely affect electric power grids. The complex interaction between space weather and the solid Earth has traditionally been approached with the use of simple 1-D impedance functions relating the inducing magnetic field to the induced geoelectric field. Ongoing data collection through the NSF EarthScope program has produced measured impedance data across much of the continental US. In this work, impedance data are convolved with magnetic field variations, obtained from USGS magnetic observatories, during a geomagnetic storm. This convolution produces geoelectric fields within the earth. These geoelectric fields are then integrated across power transmission lines to determine the voltage generated within each power line as a function of time during a geomagnetic storm. The voltages generated within the electric power grid will be shown for several historic geomagnetic storms. The estimated voltages calculated from 1-D and 3-D impedances differ by more than 100 V across some transmission lines. In combination with grounding resistance data and network topology, these voltage estimates can be utilized by power companies to estimate geomagnetically-induced currents throughout the network. These voltage estimates can provide information on which power lines are most vulnerable to geomagnetic storms, and assist power grid companies investigating where to install additional protections within their grid.

  1. TECHNICAL NOTE: Portable audio electronics for impedance-based measurements in microfluidics

    NASA Astrophysics Data System (ADS)

    Wood, Paul; Sinton, David

    2010-08-01

    We demonstrate the use of audio electronics-based signals to perform on-chip electrochemical measurements. Cell phones and portable music players are examples of consumer electronics that are easily operated and are ubiquitous worldwide. Audio output (play) and input (record) signals are voltage based and contain frequency and amplitude information. A cell phone, laptop soundcard and two compact audio players are compared with respect to frequency response; the laptop soundcard provides the most uniform frequency response, while the cell phone performance is found to be insufficient. The audio signals in the common portable music players and laptop soundcard operate in the range of 20 Hz to 20 kHz and are found to be applicable, as voltage input and output signals, to impedance-based electrochemical measurements in microfluidic systems. Validated impedance-based measurements of concentration (0.1-50 mM), flow rate (2-120 µL min-1) and particle detection (32 µm diameter) are demonstrated. The prevailing, lossless, wave audio file format is found to be suitable for data transmission to and from external sources, such as a centralized lab, and the cost of all hardware (in addition to audio devices) is ~10 USD. The utility demonstrated here, in combination with the ubiquitous nature of portable audio electronics, presents new opportunities for impedance-based measurements in portable microfluidic systems.

  2. Development of in vivo impedance spectroscopy techniques for measurement of micropore formation following microneedle insertion

    PubMed Central

    Brogden, Nicole K.; Ghosh, Priyanka; Hardi, Lucia; Crofford, Leslie J.; Stinchcomb, Audra L.

    2013-01-01

    Microneedles provide a minimally invasive means to enhance skin permeability by creating micron-scale channels (micropores) that provide a drug delivery pathway. Adequate formation of the micropores is critical to the success of this unique drug delivery technique. The objective of these studies was to develop sensitive and reproducible impedance spectroscopy techniques to monitor micropore formation in animal models and human subjects. Hairless guinea pigs, a Yucatan miniature pig, and human volunteers were treated with 100 microneedle insertions per site following an overnight pre-hydration period. Repeated measurements were made pre- and post-microneedle treatment using dry and gel Ag/AgCl electrodes applied with light vs. direct pressure to hold the electrode to the skin surface. Impedance measurements dropped significantly post-microneedle application at all sites (p < 0.05, irrespective of electrode type or gel application), confirming micropore formation. In the Yucatan pig and human subjects, gel electrodes with direct pressure yielded the lowest variability (demonstrated by lower %RSD), whereas dry electrodes with direct pressure were superior in the guinea pigs. These studies confirm that impedance measurements are suitable for use in both clinical and animal research environments to monitor formation of new micropores that will allow for drug delivery through the impermeable skin layers. PMID:23589356

  3. Development of in vivo impedance spectroscopy techniques for measurement of micropore formation following microneedle insertion.

    PubMed

    Brogden, Nicole K; Ghosh, Priyanka; Hardi, Lucia; Crofford, Leslie J; Stinchcomb, Audra L

    2013-06-01

    Microneedles (MNs) provide a minimally invasive means to enhance skin permeability by creating micron-scale channels (micropores) that provide a drug delivery pathway. Adequate formation of the micropores is critical to the success of this unique drug delivery technique. The objective of the current work was to develop sensitive and reproducible impedance spectroscopy techniques to monitor micropore formation in animal models and human subjects. Hairless guinea pigs, a Yucatan miniature pig, and human volunteers were treated with 100 MN insertions per site following an overnight prehydration period. Repeated measurements were made pre- and post-MN treatment using dry and gel Ag/AgCl electrodes applied with light verses direct pressure to hold the electrode to the skin surface. Impedance measurements dropped significantly post-MN application at all sites (p < 0.05, irrespective of electrode type or gel application), confirming micropore formation. In the Yucatan pig and human subjects, gel electrodes with direct pressure yielded the lowest variability (demonstrated by lower %relative standard deviation), whereas dry electrodes with direct pressure were superior in the guinea pigs. These studies confirm that impedance measurements are suitable for use in both clinical and animal research environments to monitor the formation of new micropores that will allow for drug delivery through the impermeable skin layers. Copyright © 2013 Wiley Periodicals, Inc.

  4. Equivalent circuit simulation of cylindrical monopole impedance measurements in ionospheric electron plasma

    NASA Astrophysics Data System (ADS)

    Kiraga, A.

    Several common problems occur in measurement techniques and interpretation of plasma natural emissions and impedance data. Antenna characteristics are of prime importance in equivalent circuit analysis. Spacecraft - plasma interaction contributes to variability of equivalent circuit impedances and e.m.f. components and imposes constrains on usefulness of experimental data. In order to have independent, built in estimate of local plasma frequency and to get deeper insight into properties of equivalent circuit for wave diagnostics, impedance measurement was integrated with radio receivers on the ACTIVE, APEX and CORONAS satellites. Impedance measurements of 7.5m long monopole were performed in frequency range .1-10MHz with the frequency step of 50kHz, in voltage divider configuration. Due to high inclination of 82.5deg and altitude range of 500-3000km, data from very different plasmas were collected. Data can be split into quasi normal, disturbed and very disturbed measurements. Equivalent circuit structure evolved in attempt to m tcha even very disturbed measurements. For quasi normal measurements, satisfactory matching is obtained with computed gyrofrequency fc and fitted plasma frequency fn, stray capacitance Cs and capacitance Cv of phenomenological vacuum sheath. With Balmain formula for monopole impedance in cold magnetoplasma, two basic spectral structures are explained. For sufficiently magnetized plasma (roughly fn/fc<2 if Cs=20pF), circuit parallel resonance frequency Fr falls into upper hybrid band (max(fn,fc),fu), resonance amplitude is reduced by high antenna resistance and horn like absolute maximum points fu. For values of fn/fc ratio, greater then critical, Fr is less than fn and broad absolute maximum at Fr follows from low antenna resistance. Further increase of fn/fc results in increasing lag of Fr behind fn. Critical rati o fn/fc increases with decreasing stray capacitance Cs. It follows from data analysis that stray capacitance may change in

  5. Amplifier spurious input current components in electrode-electrolyte interface impedance measurements.

    PubMed

    Felice, Carmelo J; Madrid, Rossana E; Valentinuzzi, Max E

    2005-03-29

    In Impedance Microbiology, the time during which the measuring equipment is connected to the bipolar cells is rather long, usually between 6 to 24 hrs for microorganisms with duplication times in the order of less than one hour and concentrations ranging from 10(1) to 10(7) [CFU/ml]. Under these conditions, the electrode-electrolyte interface impedance may show a slow drift of about 2%/hr. By and large, growth curves superimposed on such drift do not stabilize, are less reproducible, and keep on distorting all over the measurement of the temporal reactive or resistive records due to interface changes, in turn originated in bacterial activity. This problem has been found when growth curves were obtained by means of impedance analyzers or with impedance bridges using different types of operational amplifiers. Suspecting that the input circuitry was the culprit of the deleterious effect, we used for that matter (a) ultra-low bias current amplifiers, (b) isolating relays for the selection of cells, and (c) a shorter connection time, so that the relays were maintained opened after the readings, to bring down such spurious drift to a negligible value. Bacterial growth curves were obtained in order to test their quality. It was demonstrated that the drift decreases ten fold when the circuit remained connected to the cell for a short time between measurements, so that the distortion became truly negligible. Improvement due to better-input amplifiers was not as good as by reducing the connection time. Moreover, temperature effects were insignificant with a regulation of +/- 0.2 [ degrees C]. Frequency did not influence either. The drift originated either at the dc input bias offset current (Ios) of the integrated circuits, or in discrete transistors connected directly to the electrodes immersed in the cells, depending on the particular circuit arrangement. Reduction of the connection time was the best countermeasure.

  6. Amplifier spurious input current components in electrode-electrolyte interface impedance measurements

    PubMed Central

    Felice, Carmelo J; Madrid, Rossana E; Valentinuzzi, Max E

    2005-01-01

    Background In Impedance Microbiology, the time during which the measuring equipment is connected to the bipolar cells is rather long, usually between 6 to 24 hrs for microorganisms with duplication times in the order of less than one hour and concentrations ranging from 101 to 107 [CFU/ml]. Under these conditions, the electrode-electrolyte interface impedance may show a slow drift of about 2%/hr. By and large, growth curves superimposed on such drift do not stabilize, are less reproducible, and keep on distorting all over the measurement of the temporal reactive or resistive records due to interface changes, in turn originated in bacterial activity. This problem has been found when growth curves were obtained by means of impedance analyzers or with impedance bridges using different types of operational amplifiers. Methods Suspecting that the input circuitry was the culprit of the deleterious effect, we used for that matter (a) ultra-low bias current amplifiers, (b) isolating relays for the selection of cells, and (c) a shorter connection time, so that the relays were maintained opened after the readings, to bring down such spurious drift to a negligible value. Bacterial growth curves were obtained in order to test their quality. Results It was demonstrated that the drift decreases ten fold when the circuit remained connected to the cell for a short time between measurements, so that the distortion became truly negligible. Improvement due to better-input amplifiers was not as good as by reducing the connection time. Moreover, temperature effects were insignificant with a regulation of ± 0.2 [°C]. Frequency did not influence either. Conclusion The drift originated either at the dc input bias offset current (Ios) of the integrated circuits, or in discrete transistors connected directly to the electrodes immersed in the cells, depending on the particular circuit arrangement. Reduction of the connection time was the best countermeasure. PMID:15796776

  7. OP-15 FEATURES OF AEROPHAGIA MEASURED WITH MULTICHANNEL PH-IMPEDANCE IN CHILDREN.

    PubMed

    Rybak, Anna; Gomez, Carlos Tutau; Lindley, Keith; Thapar, Nikhil; Mutalib, Mohamed

    2015-10-01

    Diagnosis of aerophagia is based on clinical symptoms and described in Rome III Criteria. The aim of this study was to estimate the normal and pathological values for air swallows measured with pH-impedance in children. We analysed features of air swallowing in pH-impedance for patients hospitalized in the Great Ormond Street Hospital in 2008-2014, with the clinical symptoms of aerophagia, who have met the Rome III Criteria. Children with pH-impedance performed due to other gastrointestinal conditions (GORD, Abdominal pain, food allergy and asthma) and had normal studies comprised the control group. The exclusion criteria were: neurological, metabolic or genetic disorders, previous oesophageal surgery including fundoplication, connective tissue disorders and studies lasting less than 16 hours in durationAll studies were re analysed manually, meals were excluded from analysis. Total number of air swallows (in upright and recumbent position); mixed swallows, gastric belching and supragastric belching were counted. The results were presented as total number of episodes and as median number of episodes per hour. Impedance recording of 10 patients (7 males) with clinical aerophagia and control group of10 children (7 males) were analysed. Mean age of patients was 10 years (4.5-13.5) and 7 years in control group (4.5-17 years). Mean (±SD) recording time for patients 21.3 hrs (±2.3) for control 21.2 hrs (±1.2).Total number of liquid reflux (mean ± SD) for patients 46.9 (±22.6), control 27.6 (±15.4) p = 0.028. The median of total air swallows per hour was 30.35 (IQR: 22.6 to 43.50) in patients with aerophagia and 7.33 (IQR: 5.43 to 9.9) in control group. There were significant differences in total number of air swallows, as well as in supragastric belches between the groups (p = 0.0001 and p = 0.001, respectively). Both, air swallows and gastric belches were significantly more often observed in boys (median for boys 20.92 and 1.06; for girls 7.20 and

  8. Measurements of complex impedance in microwave high power systems with a new bluetooth integrated circuit.

    PubMed

    Roussy, Georges; Dichtel, Bernard; Chaabane, Haykel

    2003-01-01

    By using a new integrated circuit, which is marketed for bluetooth applications, it is possible to simplify the method of measuring the complex impedance, complex reflection coefficient and complex transmission coefficient in an industrial microwave setup. The Analog Devices circuit AD 8302, which measures gain and phase up to 2.7 GHz, operates with variable level input signals and is less sensitive to both amplitude and frequency fluctuations of the industrial magnetrons than are mixers and AM crystal detectors. Therefore, accurate gain and phase measurements can be performed with low stability generators. A mechanical setup with an AD 8302 is described; the calibration procedure and its performance are presented.

  9. Complex numbers in chemometrics: examples from multivariate impedance measurements on lipid monolayers.

    PubMed

    Geladi, Paul; Nelson, Andrew; Lindholm-Sethson, Britta

    2007-07-09

    Electrical impedance gives multivariate complex number data as results. Two examples of multivariate electrical impedance data measured on lipid monolayers in different solutions give rise to matrices (16x50 and 38x50) of complex numbers. Multivariate data analysis by principal component analysis (PCA) or singular value decomposition (SVD) can be used for complex data and the necessary equations are given. The scores and loadings obtained are vectors of complex numbers. It is shown that the complex number PCA and SVD are better at concentrating information in a few components than the naïve juxtaposition method and that Argand diagrams can replace score and loading plots. Different concentrations of Magainin and Gramicidin A give different responses and also the role of the electrolyte medium can be studied. An interaction of Gramicidin A in the solution with the monolayer over time can be observed.

  10. Impedance Measurement of a Gamma-Ray TES Calorimeter with a Bulk Sn Absorber

    SciTech Connect

    Akamatsu, H.; Ishisaki, Y.; Hoshino, A.

    2009-12-16

    We performed complex impedance measurements with a Ti/Au-based gamma-ray TES calorimeter with a bulk Sn absorber. Excellent energy resolution of 38.4{+-}0.9eV at 60 keV was observed. The impedance of the calorimeter can be well explained by a two-body thermal model. We investigated the behavior of the parameters of the calorimeter during the superconducting-to-normal transition. We confirmed that C and G{sub a} are in good agreement with the predicted values. We performed a noise analysis and found several excess noise components, as well as internal thermal fluctuation noise (ITFN) term due to the thermal conductance between the Sn absorber and themore » Ti/Au TES. Dominanting the noise is an excess noise having a similar frequency dependence to the phonon noise and the ITFN noise.« less

  11. Development of an Algorithm for Automatic Analysis of the Impedance Spectrum Based on a Measurement Model

    NASA Astrophysics Data System (ADS)

    Kobayashi, Kiyoshi; Suzuki, Tohru S.

    2018-03-01

    A new algorithm for the automatic estimation of an equivalent circuit and the subsequent parameter optimization is developed by combining the data-mining concept and complex least-squares method. In this algorithm, the program generates an initial equivalent-circuit model based on the sampling data and then attempts to optimize the parameters. The basic hypothesis is that the measured impedance spectrum can be reproduced by the sum of the partial-impedance spectra presented by the resistor, inductor, resistor connected in parallel to a capacitor, and resistor connected in parallel to an inductor. The adequacy of the model is determined by using a simple artificial-intelligence function, which is applied to the output function of the Levenberg-Marquardt module. From the iteration of model modifications, the program finds an adequate equivalent-circuit model without any user input to the equivalent-circuit model.

  12. Measurement of thin liquid film drainage using a novel high-speed impedance analyzer

    NASA Astrophysics Data System (ADS)

    Hool, Kevin O.; Saunders, Robert C.; Ploehn, Harry J.

    1998-09-01

    This work describes the design and implementation of a new instrument, called the thin film impedance analyzer, which measures the rate of drainage of thin oil films. The instrument forms an oil film by elevating a planar oil-water interface into a water drop hanging from a stainless steel capillary tube immersed in the oil. The instrument measures the magnitude of the impedance of the matter between the capillary tube and a screen electrode immersed in the lower water phase. Under appropriate conditions, the capacitance of the oil film dominates the impedance. The instrument records the increase in the magnitude of the admittance associated with the draining and thinning of the oil film. The features of the drainage curves vary considerably with the type, amount, and location of surfactants in the oil and water phases, as well as with user-specified values of drop volume, drop equilibration time, and extent of drop compression. For this reason, the instrument has utility as a screening tool for selecting surfactants for emulsion formulations. Potential future uses include accelerated prediction of emulsion stability and extraction of oil-water interfacial rheological parameters.

  13. Evaluation method for corrosion level of rebar in RC with electrical impedance measurement

    NASA Astrophysics Data System (ADS)

    Sasamoto, Akira

    2018-04-01

    The author reported that the impedance measurement using the 4-terminal method on the RC surface for diagnosing corrosion of internal rebar. The difference between the maximum value at 0.01 Hz and the minimum value around 10 Hz indicates the corrosion level of rebar in that report. This is successive report on a signal processing method for estimating the corrosion level by the measured impedance data to obtain more high accuracy. In the dielectric, a graph of frequency and dielectric constant (Cole-Cole plot diagram by KS Cole and RH Cole article of 1941) draws a shape of circle if the dielectric is independent of frequency but it draws a shape of ellipse in reality due to frequency dependency. Havriliak and Negami have also presented Havriliak-Negami model which introduced parameter into dielectric constant equation which deforms Cole-Cole plot diagram and showed that acquired dielectric data of polymer materials fit to this model with proper parameters. In this report, we first consider electric model connected with resistance and capacitance as a rough model of RC concrete. If the capacitance in this model circuit has some loss of dielectric, it is stated that graph in impedance plot is expected to take as similar deformation in the dielectric Cole-Cole plot. Then a numerical optimization computer code for obtaining parameters in the Cole-Cole plot diagram and Havriliak-Negami model is constructed, and the correlation between the deformation parameter of each model and corrosion is shown by this code. These results are feasibility study for diagnosis of corrosion level of rebar by associated parameters to a shape of impedance graph.

  14. A new bioimpedance research device (BIRD) for measuring the electrical impedance of acupuncture meridians.

    PubMed

    Wong, Felix Wu Shun; Lim, Chi Eung Danforn; Smith, Warren

    2010-03-01

    The aim of this article is to introduce an electrical bioimpedance device that uses an old and little-known impedance measuring technique to study the impedance of the meridian and nonmeridian tissue segments. Three (3) pilot experimental studies involving both a tissue phantom (a cucumber) and 3 human subjects were performed using this BIRD-I (Bioimpedance Research Device) device. This device consists of a Fluke RCL meter, a multiplexer box, a laptop computer, and a medical-grade isolation transformer. Segment and surface sheath (or local) impedances were estimated using formulae first published in the 1930s, in an approach that differs from that of the standard four-electrode technique used in most meridian studies to date. Our study found that, when using a quasilinear four-electrode arrangement, the reference electrodes should be positioned at least 10 cm from the test electrodes to ensure that the segment (or core) impedance estimation is not affected by the proximity of the reference electrodes. A tissue phantom was used to determine the repeatability of segment (core) impedance measurement by the device. An applied frequency of 100 kHz was found to produce the best repeatability among the various frequencies tested. In another preliminary study, with a segment of the triple energizer meridian on the lower arm selected as reference segment, core resistance-based profiles around the lower arm showed three of the other five meridians to exist as local resistance minima relative to neighboring nonmeridian segments. The profiles of the 2 subjects tested were very similar, suggesting that the results are unlikely to be spurious. In electrical bioimpedance studies, it is recommended that the measuring technique and device be clearly defined and standardized to provide optimal working conditions. In our study using the BIRD I device, we defined our standard experimental conditions as a test frequency of 100 kHz and the position of the reference electrodes of at

  15. A critical analysis of single-frequency LCR databridge impedance measurements of human skin.

    PubMed

    White, Erick A; Orazem, Mark E; Bunge, Annette L

    2011-06-01

    Testing whether the barrier of skin samples has sufficient integrity for meaningful measurements of in-vitro chemical permeability is usually required when data are generated for regulatory purposes. Recently, skin integrity has been assessed using LCR databridge measurements, which are reported as resistances determined in either series (SER) or parallel (PAR) modes at a single frequency, typically 100 or 1000Hz. Measurements made at different combinations of mode and frequency are known to differ, although the skin literature reveals confusion over the meaning of these differences and the impact on the interpretation of integrity test results. Here, the theoretical meanings of resistance and capacitance measurements in PAR and SER mode are described and confirmed experimentally. SER-mode resistances are equal to the real part of the complex impedance; whereas, PAR-mode resistances are the inverse of the real part of the admittance. Capacitance measurements reported in SER and PAR modes are similar manipulations of the imaginary parts of the complex impedance and admittance. A large body of data from human cadaver skin is used to show that the PAR-mode resistance and SER-mode capacitance measured at 100Hz are sensitive to skin resistivity, which is the electrical measurement most closely related to skin integrity. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery.

    PubMed

    Aglzim, El-Hassane; Rouane, Amar; El-Moznine, Reddad

    2007-10-17

    In this paper we present an inexpensive electronic measurement instrumentationdeveloped in our laboratory, to measure and plot the impedance of a loaded fuel cell orbattery. Impedance measurements were taken by using the load modulation method. Thisinstrumentation has been developed around a VXI system stand which controls electroniccards. Software under Hpvee ® was developed for automatic measurements and the layout ofthe impedance of the fuel cell on load. The measurement environment, like the ambienttemperature, the fuel cell temperature, the level of the hydrogen, etc..., were taken withseveral sensors that enable us to control the measurement. To filter the noise and theinfluence of the 50Hz, we have implemented a synchronous detection which filters in a verynarrow way around the useful signal. The theoretical result obtained by a simulation underPspice ® of the method used consolidates the choice of this method and the possibility ofobtaining correct and exploitable results. The experimental results are preliminary results ona 12V vehicle battery, having an inrush current of 330A and a capacity of 40Ah (impedancemeasurements on a fuel cell are in progress, and will be the subject of a forthcoming paper).The results were plotted at various nominal voltages of the battery (12.7V, 10V, 8V and 5V)and with two imposed currents (0.6A and 4A). The Nyquist diagram resulting from theexperimental data enable us to show an influence of the load of the battery on its internalimpedance. The similitude in the graph form and in order of magnitude of the valuesobtained (both theoretical and practical) enables us to validate our electronic measurementinstrumentation. One of the future uses for this instrumentation is to integrate it with several control sensors, on a vehicle as an embedded system to monitor the degradation of fuel cell membranes.

  17. Attenuation Compensation of Ultrasonic Wave in Soft Tissue for Acoustic Impedance Measurement of In vivo Bone by Transducer Vibration Method

    NASA Astrophysics Data System (ADS)

    Yoshizawa, Masasumi; Nakamura, Yuuta; Ishiguro, Masataka; Moriya, Tadashi

    2007-07-01

    In this paper, we describe a method of compensating the attenuation of the ultrasound caused by soft tissue in the transducer vibration method for the measurement of the acoustic impedance of in vivo bone. In the in vivo measurement, the acoustic impedance of bone is measured through soft tissue; therefore, the amplitude of the ultrasound reflected from the bone is attenuated. This attenuation causes an error of the order of -20 to -30% when the acoustic impedance is determined from the measured signals. To compensate the attenuation, the attenuation coefficient and length of the soft tissue are measured by the transducer vibration method. In the experiment using a phantom, this method allows the measurement of the acoustic impedance typically with an error as small as -8 to 10%.

  18. The performance of integrated transconductance amplifiers as variable current sources for bio-electric impedance measurements.

    PubMed

    Smith, D N

    1992-01-01

    Multiple applied current impedance measurement systems require numbers of current sources which operate simultaneously at the same frequency and within the same phase but at variable amplitudes. Investigations into the performance of some integrated operational transconductance amplifiers as variable current sources are described. Measurements of breakthrough, non-linearity and common-mode output levels for LM13600, NE5517 and CA3280 were carried out. The effects of such errors on the overall performance and stability of multiple current systems when driving floating loads are considered.

  19. Technique for measurement of characteristic impedance and propagation constant for porous materials

    NASA Astrophysics Data System (ADS)

    Jung, Ki Won; Atchley, Anthony A.

    2005-09-01

    Knowledge of acoustic properties such as characteristic impedance and complex propagation constant is useful to characterize the acoustic behaviors of porous materials. Song and Bolton's four-microphone method [J. Acoust. Soc. Am. 107, 1131-1152 (2000)] is one of the most widely employed techniques. In this method two microphones are used to determine the complex pressure amplitudes for each side of a sample. Muehleisen and Beamer [J. Acoust. Soc. Am. 117, 536-544 (2005)] improved upon a four-microphone method by interchanging microphones to reduce errors due to uncertainties in microphone response. In this paper, a multiple microphone technique is investigated to reconstruct the pressure field inside an impedance tube. Measurements of the acoustic properties of a material having square cross-section pores is used to check the validity of the technique. The values of characteristic impedance and complex propagation constant extracted from the reconstruction agree well with predicted values. Furthermore, this technique is used in investigating the acoustic properties of reticulated vitreous carbon (RVC) in the range of 250-1100 Hz.

  20. Predicting burst pressure of radiofrequency-induced colorectal anastomosis by bio-impedance measurement.

    PubMed

    Zhao, Lingxi; Zhou, Yu; Song, Chengli; Wang, Zhigang; Cuschieri, Alfred

    2017-03-01

    The present study investigates the relationship between bio-impedance and burst pressure of colorectal anastomosis created by radiofrequency (RF)-induced tissue fusion. Colorectal anastomosis were created with ex vivo porcine colorectal segments, during which 5 levels of compression pressure were applied by a custom-made bipolar prototype, with 5 replicate experiments at each compression pressure. Instant anastomotic tensile strength was assessed by burst pressure. Bio-impedance of fused tissue was measured by Impedance Analyzer across frequency that 100 Hz to 3 MHz. Statistical analysis shows only a weak correlation between bio-impedance modulus and burst pressures at frequency of 445 kHz ([Formula: see text]  =  -0.426, P  =  0.099  >  0.05). In contrast, results demonstrated a highly significant negative correlation between reactance modulus and burst pressures ([Formula: see text]  =  -0.812, P  =  0.000  <  0.05). The decrease in mean reactance modulus with increasing burst pressures was highly significant (P  =  0.019  <  0.05). The observed strong negative correlation between reactance modulus and burst pressures at frequency of 445 kHz indicates that reactance is likely to be a good index for tensile strength of RF-induced colorectal anastomosis, and should be considered for inclusion in a feedback loops in devices design.

  1. Impact of eating and drinking on body composition measurements by bioelectrical impedance.

    PubMed

    Androutsos, O; Gerasimidis, K; Karanikolou, A; Reilly, J J; Edwards, C A

    2015-04-01

    Bioelectrical impedance analysis would be a more practical tool to measure body composition in clinical settings, dietetic practice and epidemiological studies if patients/subjects did not have to fast before measurements. The present study assessed whether the ingestion of food or drink had any biologically significant effect on bioimpedance measurements and body composition by the foot-to-foot method. Fifty-five healthy adults [30 males and 25 females; mean (SD) age 27.7 (7.1) years; mean (SD)body mass index 24 (3.8) kg m(-2)] were randomly assigned to a 2-day food trial (high-fat meal or high-carbohydrate meal) or a 2-day drink trial (water or high electrolyte drink). Body composition measurements were carried out in the fasting state, immediately after meal consumption and every 30 min for 2 h by the foot-to-foot single frequency bioimpedance technique. Bioimpedance increased significantly after the ingestion of food and fluid, although the changes were small. The electrolyte drink, high-fat and high-carbohydrate meals significantly increased the percentage body fat and fat mass. In all cases, the median percentage changes from baseline were approximately 1% in body fat percentage units. Although there were statistically significant changes in body composition estimates after food or drink consumption, these were small and within the imprecision of the impedance technique, and so are unlikely to be of clinical significance. The present study suggests that impedance measures of body fatness in clinical settings do not require strict adherence to fasting, and this should increase the opportunities for clinical application. © 2014 The British Dietetic Association Ltd.

  2. A new lithium-ion battery internal temperature on-line estimate method based on electrochemical impedance spectroscopy measurement

    NASA Astrophysics Data System (ADS)

    Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.

    2015-01-01

    The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.

  3. Association between respiratory impedance measured by forced oscillation technique and exacerbations in patients with COPD.

    PubMed

    Yamagami, Hitomi; Tanaka, Akihiko; Kishino, Yasunari; Mikuni, Hatsuko; Kawahara, Tomoko; Ohta, Shin; Yamamoto, Mayumi; Suzuki, Shintaro; Ohnishi, Tsukasa; Sagara, Hironori

    2018-01-01

    It is well known that increased airflow limitation as measured by spirometry is associated with the risk of exacerbation in patients with COPD. The forced oscillation technique (FOT) is a noninvasive method used to assess respiratory impedance (resistance and reactance) with minimal patient cooperation required. The clinical utility of the FOT in assessing the risk of exacerbations of COPD is yet to be determined. We examined the relationship between respiratory impedance as measured by FOT and exacerbations in patients with COPD. Among 310 patients with COPD (Global Initiative for Chronic Obstructive Lung Disease stages I-IV) who presented at the outpatient clinic of the Showa University Hospital from September 2014 through January 2015, 119 were collected and assigned into 2 groups according to their history of exacerbation: exacerbators and nonexacerbators. Respiratory resistance components and respiratory reactance components, as measured by FOT, were compared between the two groups. Exacerbators were significantly older and had a higher white blood cell count than nonexacerbators. Resistance at 20 Hz, reactance at 5 Hz (X5), resonant frequency (Fres), and area of low reactance (ALX) differed significantly between the two groups. In addition, among patients with stage II COPD, there were significant differences in X5, Fres, and ALX between the two groups despite no significant differences in respiratory function as assessed by spirometry. Finally, receiver operating characteristic curve analysis revealed that the reactance components rather than the resistance components were associated with the risk of exacerbation. There were significant differences in respiratory impedance between exacerbators and nonexacerbators in patients with moderate COPD. FOT is a promising tool for assessing future exacerbations in patients with COPD.

  4. Structural damage identification using piezoelectric impedance measurement with sparse inverse analysis

    NASA Astrophysics Data System (ADS)

    Cao, Pei; Qi, Shuai; Tang, J.

    2018-03-01

    The impedance/admittance measurements of a piezoelectric transducer bonded to or embedded in a host structure can be used as damage indicator. When a credible model of the healthy structure, such as the finite element model, is available, using the impedance/admittance change information as input, it is possible to identify both the location and severity of damage. The inverse analysis, however, may be under-determined as the number of unknowns in high-frequency analysis is usually large while available input information is limited. The fundamental challenge thus is how to find a small set of solutions that cover the true damage scenario. In this research we cast the damage identification problem into a multi-objective optimization framework to tackle this challenge. With damage locations and severities as unknown variables, one of the objective functions is the difference between impedance-based model prediction in the parametric space and the actual measurements. Considering that damage occurrence generally affects only a small number of elements, we choose the sparsity of the unknown variables as another objective function, deliberately, the l 0 norm. Subsequently, a multi-objective Dividing RECTangles (DIRECT) algorithm is developed to facilitate the inverse analysis where the sparsity is further emphasized by sigmoid transformation. As a deterministic technique, this approach yields results that are repeatable and conclusive. In addition, only one algorithmic parameter, the number of function evaluations, is needed. Numerical and experimental case studies demonstrate that the proposed framework is capable of obtaining high-quality damage identification solutions with limited measurement information.

  5. Ventilation inhomogeneity in obstructive lung diseases measured by electrical impedance tomography: a simulation study.

    PubMed

    Schullcke, B; Krueger-Ziolek, S; Gong, B; Jörres, R A; Mueller-Lisse, U; Moeller, K

    2017-10-10

    Electrical impedance tomography (EIT) has mostly been used in the Intensive Care Unit (ICU) to monitor ventilation distribution but is also promising for the diagnosis in spontaneously breathing patients with obstructive lung diseases. Beside tomographic images, several numerical measures have been proposed to quantitatively assess the lung state. In this study two common measures, the 'Global Inhomogeneity Index' and the 'Coefficient of Variation' were compared regarding their capability to reflect the severity of lung obstruction. A three-dimensional simulation model was used to simulate obstructed lungs, whereby images were reconstructed on a two-dimensional domain. Simulations revealed that minor obstructions are not adequately recognized in the reconstructed images and that obstruction above and below the electrode plane may result in misleading values of inhomogeneity measures. EIT measurements on several electrode planes are necessary to apply these measures in patients with obstructive lung diseases in a promising manner.

  6. A Comparison Study of Normal-Incidence Acoustic Impedance Measurements of a Perforate Liner

    NASA Technical Reports Server (NTRS)

    Schultz, Todd; Liu, Fei; Cattafesta, Louis; Sheplak, Mark; Jones, Michael

    2009-01-01

    The eduction of the acoustic impedance for liner configurations is fundamental to the reduction of noise from modern jet engines. Ultimately, this property must be measured accurately for use in analytical and numerical propagation models of aircraft engine noise. Thus any standardized measurement techniques must be validated by providing reliable and consistent results for different facilities and sample sizes. This paper compares normal-incidence acoustic impedance measurements using the two-microphone method of ten nominally identical individual liner samples from two facilities, namely 50.8 mm and 25.4 mm square waveguides at NASA Langley Research Center and the University of Florida, respectively. The liner chosen for this investigation is a simple single-degree-of-freedom perforate liner with resonance and anti-resonance frequencies near 1.1 kHz and 2.2 kHz, respectively. The results show that the ten measurements have the most variation around the anti-resonance frequency, where statistically significant differences exist between the averaged results from the two facilities. However, the sample-to-sample variation is comparable in magnitude to the predicted cross-sectional area-dependent cavity dissipation differences between facilities, providing evidence that the size of the present samples does not significantly influence the results away from anti-resonance.

  7. Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

    NASA Technical Reports Server (NTRS)

    Humphreys, William M., Jr.; Bartram, Scott M.; Parrott, Tony L.; Jones, Michael G.

    1998-01-01

    Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

  8. Measurement of lung function using Electrical Impedance Tomography (EIT) during mechanical ventilation

    NASA Astrophysics Data System (ADS)

    Nebuya, Satoru; Koike, Tomotaka; Imai, Hiroshi; Noshiro, Makoto; Brown, Brian H.; Soma, Kazui

    2010-04-01

    The consistency of regional lung density measurements as estimated by Electrical Impedance Tomography (EIT), in eleven patients supported by a mechanical ventilator, was validated to verify the feasibility of its use in intensive care medicine. There were significant differences in regional lung densities between the normal lung and diseased lungs associated with pneumonia, atelectasis and pleural effusion (Steel-Dwass test, p < 0.05). Temporal changes in regional lung density of patients with atelectasis were observed to be in good agreement with the results of clinical diagnosis. These results indicate that it is feasible to obtain a quantitative value for regional lung density using EIT.

  9. Multifrequency impedance measurement technique for wireless characterization of microbiological cell cultures

    NASA Astrophysics Data System (ADS)

    Wissenwasser, J.; Vellekoop, M. J.; Kapferer, W.; Lepperdinger, G.; Heer, R.

    2011-11-01

    An impedance measurement system with probe signal frequencies up to 50 kHz with AC-probe voltages below 30 mV rms was integrated for wireless and battery-free monitoring of microbiological cell cultures. The here presented modular design and the use of state-of-the-art components greatly eases adoptions to a wide range of biotechnological applications without the need of bulky LCR-meters or potentiostats. The device had a power consumption of less than 2.5 mA at a 3.3 V single power supply and worked trouble-free within the humid environment of a cell culture incubator. Measurements on lumped RC-elements showed an error of less than 1% for absolute values and less than 1° regarding the phase of the complex impedance. The performance of sensor devices with interdigitated electrode structures for the measurement of adherent cell cultures was tested in the presence of phosphate-buffered saline solution in the humid atmosphere of an incubator for biological cell cultures.

  10. Characterizing Esophageal Cancerous Cells at Different Stages Using the Dielectrophoretic Impedance Measurement Method in a Microchip.

    PubMed

    Wang, Hsiang-Chen; Nguyen, Ngoc-Viet; Lin, Rui-Yi; Jen, Chun-Ping

    2017-05-06

    Analysis of cancerous cells allows us to provide useful information for the early diagnosis of cancer and to monitor treatment progress. An approach based on electrical principles has recently become an attractive technique. This study presents a microdevice that utilizes a dielectrophoretic impedance measurement method for the identification of cancerous cells. The proposed biochip consists of circle-on-line microelectrodes that are patterned using a standard microfabrication processes. A sample of various cell concentrations was introduced in an open-top microchamber. The target cells were collectively concentrated between the microelectrodes using dielectrophoresis manipulation, and their electrical impedance properties were also measured. Different stages of human esophageal squamous cell carcinoma lines could be distinguished. This result is consistent with findings using hyperspectral imaging technology. Moreover, it was observed that the distinguishing characteristics change in response to the progression of cancer cell invasiveness by Raman spectroscopy. The device enables highly efficient cell collection and provides rapid, sensitive, and label-free electrical measurements of cancerous cells.

  11. Monitoring of pipelines in nuclear power plants by measuring laser-based mechanical impedance

    NASA Astrophysics Data System (ADS)

    Lee, Hyeonseok; Sohn, Hoon; Yang, Suyoung; Yang, Jinyeol

    2014-06-01

    Using laser-based mechanical impedance (LMI) measurement, this study proposes a damage detection technique that enables structural health monitoring of pipelines under the high temperature and radioactive environments of nuclear power plants (NPPs). The applications of conventional electromechanical impedance (EMI) based techniques to NPPs have been limited, mainly due to the contact nature of piezoelectric transducers, which cannot survive under the high temperature and high radiation environments of NPPs. The proposed LMI measurement technique aims to tackle the limitations of the EMI techniques by utilizing noncontact laser beams for both ultrasound generation and sensing. An Nd:Yag pulse laser is used for ultrasound generation, and a laser Doppler vibrometer is employed for the measurement of the corresponding ultrasound responses. For the monitoring of pipes covered by insulation layers, this study utilizes optical fibers to guide the laser beams to specific target locations. Then, an outlier analysis is adopted for autonomous damage diagnosis. Validation of the proposed LMI technique is carried out on a carbon steel pipe elbow under varying temperatures. A corrosion defect chemically engraved in the specimen is successfully detected.

  12. Validation of bioelectrical-impedance analysis as a measurement of change in body composition in obesity

    SciTech Connect

    Kushner, R.F.; Kunigk, A.; Alspaugh, M.

    1990-08-01

    The bioelectrical-impedance-analysis (BIA) method accurately measures body composition in weight-stable subjects. This study validates the use of BIA to measure change in body composition. Twelve obese females underwent weight loss at a mean rate of 1.16 kg/wk. Body composition was measured by deuterium oxide dilution (D2O), BIA, and skinfold anthropometry (SFA) at baseline and at 5% decrements in weight. Highly significant correlations were obtained between D2O and BIA (r = 0.971) and between D2O and SFA (r = 0.932). Overall, BIA predicted change in fat-free mass with greater accuracy (to 0.4 kg) and precision (+/- 1.28 kg) than did anthropometrymore » (to 0.8 kg and +/- 2.58 kg, respectively). We conclude that BIA is a useful clinical method for measuring change in body composition.« less

  13. Impedance measurements on a spiral-wound nickel/metal hydride cell cycled in a simulated Leo orbit

    NASA Technical Reports Server (NTRS)

    Reid, Margaret A.

    1993-01-01

    A spiral-wound size C cell was cycled at 25 C in a low earth orbit (LEO) regime at 50 percent depth of discharge (DOD) with approximately five percent over-charge. The nominal capacity was 3.5 AH. The cell was cycled for 2000 cycles. Capacity checks and impedance measurements over the complete range of state of charge were made upon receipt and after 500, 1000, and 2000 cycles. The capacity of the cell was essentially unchanged until after the impedance measurements at 2000 cycles. Only small changes in the impedance parameters were observed, but there was somewhat more scatter in the data after 2000 cycles. When the cell was returned to LEO cycling after 2000 cycles, only 38 percent of the capacity could be obtained. It is believed that the cell failed because of an equipment failure at the end of the final impedance measurements which allowed an over-discharge.

  14. Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

    PubMed

    Järverud, K; Ollmar, S; Brodin, L A

    2002-09-01

    Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, sinus rhythm 100.3 +/- 16.5 beats min(-1), average impedance 629.8 +/- 72.6 ohms; and two dogs: 30 kg each, sinus rhythm 86.0 beats min(-1), 862.1 ohms and 134.0 beats min(-1), 1114.6 ohms, respectively). The averaged curve and standard deviation curve of the impedance in sinus rhythm were analysed in MATLAB to clarify and study consistent impedance shape over one heart cycle. In eight of nine (89%) animal subjects, a consistent impedance slope change (notch) was observed in the early stage of the cardiac filling phase. This result was reproduced in an additional subject with simultaneous echocardiographical measurements of mitral valve blood flow. The notch occured soon after rapid early filling (E-wave in mitral flow) but prior to ventricular filling caused by atrial contraction, indicating that the impedance notch was caused by rapid ventricular filling and that it might be a sensed feature of diagnostic value. The intracardiac impedance notch in the present study had similar features to the non-invasive transthoracic impedance O-wave reported by others, and it is shown here that an O-wave is found in intracardiac impedance signals, strongly suggesting that the non-invasive O-wave is caused by cardiac events.

  15. Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults

    PubMed Central

    Macias, Nayeli; Alemán-Mateo, Heliodoro; Esparza-Romero, Julián; Valencia, Mauro E

    2007-01-01

    Background The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA) requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP) as standard method to measure body composition in Mexican adult men and women. Methods This study included 155 male and female subjects from northern Mexico, 20–50 years of age, from low, middle, and upper income levels. Body composition was measured by ADP. Body weight (BW, kg) and height (Ht, cm) were obtained by standard anthropometric techniques. Resistance, R (ohms) and reactance, Xc (ohms) were also measured. A random-split method was used to obtain two samples: one was used to derive the equation by the "all possible regressions" procedure and was cross-validated in the other sample to test predicted versus measured values of fat-free mass (FFM). Results and Discussion The final model was: FFM (kg) = 0.7374 * (Ht2 /R) + 0.1763 * (BW) - 0.1773 * (Age) + 0.1198 * (Xc) - 2.4658. R2 was 0.97; the square root of the mean square error (SRMSE) was 1.99 kg, and the pure error (PE) was 2.96. There was no difference between FFM predicted by the new equation (48.57 ± 10.9 kg) and that measured by ADP (48.43 ± 11.3 kg). The new equation did not differ from the line of identity, had a high R2 and a low SRMSE, and showed no significant bias (0.87 ± 2.84 kg). Conclusion The new bioelectrical impedance equation based on the two-compartment model (2C) was accurate, precise, and free of bias. This equation can be used to assess body composition and nutritional status in populations similar in anthropometric and physical characteristics to this sample. PMID:17697388

  16. Bio-electrical impedance spectroscopy: alternatives for the conventional hand-to-foot measurements.

    PubMed

    Cox-Reijven, P L M; Van Kreel, B; Soeters, P B

    2002-04-01

    Bio-impedance spectroscopy (BIS) is a very attractive method for measuring body composition. The standard method measures impedance from hand to foot. However, in patients a hand or foot is not always accessible. In these cases alternative methods would be helpful. The objective of this study was to compare BIS measurements from hand to foot (HF) with foot to foot (FF) and hand to hand (HH) measurements as alternatives. Aims were firstly, to assess the relationship between resistance (R) values measured by the different methods, secondly, to study the influence of body geometry on this relationship and lastly, to assess the predictive capacity of the methods for measuring body fluid volumes. In 53 subjects with different degrees of obesity (mean BMI = 38; SD = 9 kg/m(2)) three BIS measurements were performed from HF, HH and FF with a Xitron 4000B machine. Resistances of extracellular (Recw) and intracellular water (Ricw) were extrapolated by fitting the data to a Cole-Cole plot. Total body water (TBW) and extracellular water (ECW) were measured by deuterium and bromide dilution respectively. Intracellular water (ICW) was calculated as TBW-ECW. Anthropometric measurements, including length and circumference of limbs and trunk, were performed as measures for body geometry. The Recw, Ricw and R50 values of HF measurements could be accurately described as a function of the Recw, Ricw and R50 values of HH or FF measurements. The relative circumference of arms and legs and the length of the trunk influenced the relationship between R values of the three different measurements. The degree of overweight did not affect this relationship. The precision of the predictions of TBW, ECW and ICW based on R values of the HH measurements were comparable with the traditional HF measurements while the FF measurements gave slightly less accurate results. Under circumstances where total body BIS measurements cannot be performed, FF or HH measurements may be used as alternatives

  17. Validity of bioelectrical impedance measurement in predicting fat-free mass of Chinese children and adolescents.

    PubMed

    Wang, Lin; Hui, Stanley Sai-chuen; Wong, Stephen Heung-sang

    2014-11-15

    The current study aimed to examine the validity of various published bioelectrical impedance analysis (BIA) equations in estimating FFM among Chinese children and adolescents and to develop BIA equations for the estimation of fat-free mass (FFM) appropriate for Chinese children and adolescents. A total of 255 healthy Chinese children and adolescents aged 9 to 19 years old (127 males and 128 females) from Tianjin, China, participated in the BIA measurement at 50 kHz between the hand and the foot. The criterion measure of FFM was also employed using dual-energy X-ray absorptiometry (DEXA). FFM estimated from 24 published BIA equations was cross-validated against the criterion measure from DEXA. Multiple linear regression was conducted to examine alternative BIA equation for the studied population. FFM estimated from the 24 published BIA equations yielded high correlations with the directly measured FFM from DEXA. However, none of the 24 equations was statistically equivalent with the DEXA-measured FFM. Using multiple linear regression and cross-validation against DEXA measurement, an alternative prediction equation was determined as follows: FFM (kg)=1.613+0.742×height (cm)2/impedance (Ω)+0.151×body weight (kg); R2=0.95; SEE=2.45 kg; CV=6.5, 93.7% of the residuals of all the participants fell within the 95% limits of agreement. BIA was highly correlated with FFM in Chinese children and adolescents. When the new developed BIA equations are applied, BIA can provide a practical and valid measurement of body composition in Chinese children and adolescents.

  18. Validity of Bioelectrical Impedance Measurement in Predicting Fat-Free Mass of Chinese Children and Adolescents

    PubMed Central

    Wang, Lin; Hui, Stanley Sai-chuen; Wong, Stephen Heung-sang

    2014-01-01

    Background The current study aimed to examine the validity of various published bioelectrical impedance analysis (BIA) equations in estimating FFM among Chinese children and adolescents and to develop BIA equations for the estimation of fat-free mass (FFM) appropriate for Chinese children and adolescents. Material/Methods A total of 255 healthy Chinese children and adolescents aged 9 to 19 years old (127 males and 128 females) from Tianjin, China, participated in the BIA measurement at 50 kHz between the hand and the foot. The criterion measure of FFM was also employed using dual-energy X-ray absorptiometry (DEXA). FFM estimated from 24 published BIA equations was cross-validated against the criterion measure from DEXA. Multiple linear regression was conducted to examine alternative BIA equation for the studied population. Results FFM estimated from the 24 published BIA equations yielded high correlations with the directly measured FFM from DEXA. However, none of the 24 equations was statistically equivalent with the DEXA-measured FFM. Using multiple linear regression and cross-validation against DEXA measurement, an alternative prediction equation was determined as follows: FFM (kg)=1.613+0.742×height (cm)2/impedance (Ω)+0.151×body weight (kg); R2=0.95; SEE=2.45kg; CV=6.5, 93.7% of the residuals of all the participants fell within the 95% limits of agreement. Conclusions BIA was highly correlated with FFM in Chinese children and adolescents. When the new developed BIA equations are applied, BIA can provide a practical and valid measurement of body composition in Chinese children and adolescents. PMID:25398209

  19. On impedance measurement of reinforced concrete on the surface for estimate of corroded rebar

    NASA Astrophysics Data System (ADS)

    Sasamoto, Akira; Yu, Jun; Harada, Yoshihisa; Iwata, Masahiro; Noguchi, Kazuhiro

    2017-04-01

    In an estimate of health monitoring for reinforced concrete, corrosion degree of rebar is important parameter but is not easy to be estimated by non destructive testing. A few test method such as half cell method or polarization resistance method could be a 'perfect' nondestructive method if luckily having had wired connection to rebar without destructing target concrete. In this presentation it is reported the experimental result that an impedance measurement on surface of reinforced concretes is able to distinguish corroded rebar from healthy rebar. The contact electrode on concrete surface are simple structure made of urethane sponge and needle. Impedance measurement are carried out with frequency response analyzer with frequency range from 0.01Hz to 1MHz, typical amplitude of imposed voltage are 10 volt. We made concrete specimens under two different corrosion process. One process(pre corrosion) has rebars corroded by electrolysis in salty water before concrete casting and another process (post corrosion) has concrete specimens being corroded during the curing. The results of application of developed method to these corroded specimens show the method is useful to estimate corrosion level of rebars.

  20. Impedance measures in analysis and characterization of multistable structures subjected to harmonic excitation

    NASA Astrophysics Data System (ADS)

    Harne, Ryan L.; Goodpaster, Benjamin A.

    2018-01-01

    Structural components susceptible to adverse, post-buckled dynamic behaviors have long challenged the success of applications requiring lightweight, slender curved structures, while researchers have begun to leverage such bistable systems in emerging applications for novel energy attenuation and shape-changing properties. To expedite development and deployment of these built-up platforms containing post-buckled constituents, efficient approaches are required to complement time-consuming full-field models in the prediction of the near- and far-from-equilibrium dynamics. This research meets the need by introducing a semi-analytical model framework to enable the characterization of steady-state responses in multi degree-of-freedom (DOF) and multistable structural systems subjected to harmonic excitation. In so doing, the pathway for assessing impedance measures is created here so as to identify how energy travels and returns within built-up multistable structures. Verified by simulations and qualitatively validated by experiments, the analysis is shown to accurately reproduce both near- and far-from-equilibrium responses including different classes of energetic snap-through dynamics that only exist in such multistable structures. A first look at the impedance measures of different dynamic regimes reveals a connection between damping in multistable structures and the sustainability of far-from-equilibrium oscillations.

  1. AN ADVANCED CALIBRATION PROCEDURE FOR COMPLEX IMPEDANCE SPECTRUM MEASUREMENTS OF ADVANCED ENERGY STORAGE DEVICES

    SciTech Connect

    William H. Morrison; Jon P. Christophersen; Patrick Bald

    With the increasing demand for electric and hybrid electric vehicles and the explosion in popularity of mobile and portable electronic devices such as laptops, cell phones, e-readers, tablet computers and the like, reliance on portable energy storage devices such as batteries has likewise increased. The concern for the availability of critical systems in turn drives the availability of battery systems and thus the need for accurate battery health monitoring has become paramount. Over the past decade the Idaho National Laboratory (INL), Montana Tech of the University of Montana (Tech), and Qualtech Systems, Inc. (QSI) have been developing the Smart Batterymore » Status Monitor (SBSM), an integrated battery management system designed to monitor battery health, performance and degradation and use this knowledge for effective battery management and increased battery life. Key to the success of the SBSM is an in-situ impedance measurement system called the Impedance Measurement Box (IMB). One of the challenges encountered has been development of an accurate, simple, robust calibration process. This paper discusses the successful realization of this process.« less

  2. Simultaneous Measurements of Ossicular Velocity and Intracochlear Pressure Leading to the Cochlear Input Impedance in Gerbil

    PubMed Central

    Decraemer, W. F.; Khanna, S. M.; Olson, E. S.

    2008-01-01

    Recent measurements of three-dimensional stapes motion in gerbil indicated that the piston component of stapes motion was the primary contributor to intracochlear pressure. In order to make a detailed correlation between stapes piston motion and intracochlear pressure behind the stapes, simultaneous pressure and motion measurements were undertaken. We found that the scala vestibuli pressure followed the piston component of the stapes velocity with high fidelity, reinforcing our previous finding that the piston motion of the stapes was the main stimulus to the cochlea. The present data allowed us to calculate cochlear input impedance and power flow into the cochlea. Both the amplitude and phase of the impedance were quite flat with frequency from 3 kHz to at least 30 kHz, with a phase that was primarily resistive. With constant stimulus pressure in the ear canal the intracochlear pressure at the stapes has been previously shown to be approximately flat with frequency through a wide range, and coupling that result with the present findings indicates that the power that flows into the cochlea is quite flat from about 3 to 30 kHz. The observed wide-band intracochlear pressure and power flow are consistent with the wide-band audiogram of the gerbil. PMID:18459001

  3. High-Frequency Electromagnetic Impedance Measurements for Characterization, Monitoring and Verification Efforts

    SciTech Connect

    Lee, Ki Ha; Becker, Alex; Tseng, Hung-Wen

    2004-06-16

    Non-invasive, high-resolution imaging of the shallow subsurface is needed for delineation of buried waste, detection of unexploded ordinance, verification and monitoring of containment structures, and other environmental applications. Electromagnetic (EM) measurements at frequencies between 0.1 and 100 MHz are important for such applications, because the induction number of many targets is small and the ability to determine the dielectric permittivity in addition to electrical conductivity of the subsurface is possible. Earlier workers were successful in developing systems for detecting anomalous areas, but no quantifiable information was accurately determined. For high-resolution imaging, accurate measurements are necessary so the field data canmore » be mapped into the space of the subsurface parameters. We are developing a non-invasive method for accurately mapping the electrical conductivity and dielectric permittivity of the shallow subsurface using the EM impedance approach (Frangos, 2001; Lee and Becker, 2001; Song et al., 2002, Tseng et al., 2003). Electric and magnetic sensors are being tested and calibrated on sea water and in a known area against theoretical predictions, thereby insuring that the data collected with the high-frequency impedance (HFI) system will support high-resolution, multi-dimensional imaging techniques.« less

  4. High Frequency Electromagnetic Impedance Measurements for Characterization, Monitoring and Verification Efforts

    SciTech Connect

    Lee, Ki Ha; Becker, Alex; Framgos, William

    1999-06-01

    Non-invasive, high-resolution imaging of the shallow subsurface is needed for delineation of buried waste, detection of unexploded ordinance, verification and monitoring of containment structures, and other environmental applications. Electromagnetic measurements at frequencies between 1 and 100 MHz are important for such applications, because the induction number of many targets is small and the ability to determine the dielectric permittivity in addition to electrical conductivity of the subsurface is possible. Earlier workers were successful in developing systems for detecting anomalous areas, but no quantifiable information was accurately determined. For high-resolution imaging, accurate measurements are necessary so the field data can bemore » mapped into the space of the subsurface parameters. We are developing a non-invasive method for accurately imaging the electrical conductivity and dielectric permittivity of the shallow subsurface using the plane wave impedance approach. Electric and magnetic sensors are being tested in a known area against theoretical predictions, thereby insuring that the data collected with the high-frequency impedance (HFI) system will support high-resolution, multi-dimensional imaging techniques.« less

  5. High-Frequency Electromagnetic Impedance Measurements for Characterization, Monitoring and Verification Efforts

    SciTech Connect

    Lee, Ki Ha; Becker, Alex; Tseng, Hung-Wen

    2002-11-20

    Non-invasive, high-resolution imaging of the shallow subsurface is needed for delineation of buried waste, detection of unexploded ordinance, verification and monitoring of containment structures, and other environmental applications. Electromagnetic (EM) measurements at frequencies between 1 and 100 MHz are important for such applications, because the induction number of many targets is small and the ability to determine the dielectric permittivity in addition to electrical conductivity of the subsurface is possible. Earlier workers were successful in developing systems for detecting anomalous areas, but no quantifiable information was accurately determined. For high-resolution imaging, accurate measurements are necessary so the field data canmore » be mapped into the space of the subsurface parameters. We are developing a non-invasive method for accurately mapping the electrical conductivity and dielectric permittivity of the shallow subsurface using the EM impedance approach (Frangos, 2001; Lee and Becker, 2001; Song et al., 2002). Electric and magnetic sensors are being tested in a known area against theoretical predictions, thereby insuring that the data collected with the high-frequency impedance (HFI) system will support high-resolution, multi-dimensional imaging techniques.« less

  6. High-Frequency Electromagnetic Impedance Measurements for Characterization, Monitoring, and Verification Efforts

    SciTech Connect

    Lee, Ki Ha; Becker, Alex

    2000-06-01

    Non-invasive, high-resolution imaging of the shallow subsurface is needed for delineation of buried waste, detection of unexploded ordinance, verification and monitoring of containment structures, and other environmental applications. Electromagnetic measurements at frequencies between 1 and 100 MHz are important for such applications, because the induction number of many targets is small and the ability to determine the dielectric permittivity in addition to electrical conductivity of the subsurface is possible. Earlier workers were successful in developing systems for detecting anomalous areas, but no quantifiable information was accurately determined. For high-resolution imaging, accurate measurements are necessary so the field data can bemore » mapped into the space of the subsurface parameters. We are developing a non-invasive method for accurately imaging the electrical conductivity and dielectric permittivity of the shallow subsurface using the plane wave impedance approach (Song et al., 1997). Electric and magnetic sensors are being tested in a known area against theoretical predictions, thereby insuring that the data collected with the high-frequency impedance (HFI) system will support high-resolution, multi-dimensional imaging techniques.« less

  7. High-Frequency Electromagnetic Impedance Measurements for Characterization, Monitoring and Verification Efforts

    SciTech Connect

    Lee, Ki Ha; Becker, Alex; Tseng, Hung-Wen

    2001-06-10

    Non-invasive, high-resolution imaging of the shallow subsurface is needed for delineation of buried waste, detection of unexploded ordinance, verification and monitoring of containment structures, and other environmental applications. Electromagnetic (EM) measurements at frequencies between 1 and 100 MHz are important for such applications, because the induction number of many targets is small and the ability to determine the dielectric permittivity in addition to electrical conductivity of the subsurface is possible. Earlier workers were successful in developing systems for detecting anomalous areas, but no quantifiable information was accurately determined. For high-resolution imaging, accurate measurements are necessary so the field data canmore » be mapped into the space of the subsurface parameters. We are developing a non-invasive method for accurately mapping the electrical conductivity and dielectric permittivity of the shallow subsurface using the EM impedance approach (Frangos, 2001; Lee and Becker, 2001). Electric and magnetic sensors are being tested in a known area against theoretical predictions, thereby insuring that the data collected with the high-frequency impedance (HFI) system will support high-resolution, multi-dimensional imaging techniques.« less

  8. Wide-Range Filter-Based Sinusoidal Wave Synthesizer for Electrochemical Impedance Spectroscopy Measurements.

    PubMed

    Chia-Ling Wei; Yi-Wen Wang; Bin-Da Liu

    2014-06-01

    A filter-based wide-range programmable sinusoidal wave synthesizer for electrochemical impedance spectroscopy measurement is proposed. The adopted filter is implemented with switched-capacitor circuits, so its corner frequency is accurate and adjustable by changing its switching frequency. The proposed sine wave synthesizer is implemented by using a 0.35 μm 2P4M 3.3 V mixed-signal polycide process. According to the measured results, the output frequency of the proposed synthesizer is 40 mHz-40 kHz . The measured total harmonic distortion is 0.073% at 10 Hz and 0.075% at 10 kHz, both of which are better than that of a typical function generator.

  9. Method and apparatus for sensing a target characteristic by measuring both impedance and resonant frequency of a tank circuit

    NASA Technical Reports Server (NTRS)

    Laskowski, Edward L. (Inventor)

    1995-01-01

    An apparatus for sensing a target characteristic, such as relative distance between the apparatus and target, target thickness, target material, or lateral position between the apparatus and the target, includes a coil for directing an electro-magnetic field at the target. A voltage controlled oscillator energizes the coil at a resonant frequency which is functionally related to the target characteristic. The coil has an effective impedance value at resonance functionally related to the target characteristic. A frequency monitor measures the resonant frequency. An impedance monitor determines the impedance value when the drive frequency is at the resonant value. A PROM or controller determines the target characteristic in response to the measured resonant frequency and the determined impedance value. The PROM or controller provides a signal responsive to the determined target characteristic.

  10. An electrode polarization impedance based flow sensor for low water flow measurement

    NASA Astrophysics Data System (ADS)

    Yan, Tinghu; Sabic, Darko

    2013-06-01

    This note describes an electrode polarization impedance based flow sensor for low water flow measurement. It consists of two pairs of stainless steel electrodes set apart and inserted into a non-conductive flow tube with each pair of electrodes placed diametrically at the opposite sides. The flow sensor is modeled as a typical four-electrode system of which two electrodes are current-carrying and the other two serve as output pick ups. The polarization impedances of the two current carrying electrodes are affected by water flows resulting in changes of differential potential between the two pick-up electrodes which are separated by the same fluid. The interrogation of the two excitation electrodes with dc biased ac signals offers significantly higher sensor sensitivities to flow. The prototype flow sensor constructed for a 20 mm diameter pipeline was able to measure water flow rate as low as tested at 1.06 l h-1 and remained sensitive at a flow rate of 25.18 l h-1 when it was driven with a sinusoidal voltage at 1000 Hz with a peak ac amplitude of 2 V and a dc offset of +8 V. The nonlinear characteristics of the sensor response indicate that the sensor is more sensitive at low flows and will not be able to measure at very high flows. Additional experiments are needed to evaluate the influences of impurities, chemical species, ions constituents, conductivity and temperature over a practical range of residential water conditions, the effects of fluctuating ground signals, measurement uncertainty, power consumption, compensation of effects and practical operations. The flow sensor (principle) presented may be used as (in) a secondary sensor in combination with an existing electronic water meter to extend the low end of measurement range in residential water metering.

  11. Focused Impedance Method (FIM) and Pigeon Hole Imaging (PHI) for localized measurements - a review

    NASA Astrophysics Data System (ADS)

    Siddique-e Rabbani, K.

    2010-04-01

    This paper summarises up to date development in Focused Impedance Method (FIM) initiated by us. It basically involves taking the sum of two orthogonal tetra-polar impedance measurements around a common central region, giving a localized enhanced sensitivity. Although the basic idea requires 8 electrodes, versions with 6- and 4-electrodes were subsequently conceived and developed. The focusing effect has been verified in 2D and 3D phantoms and through numerical analysis. Dynamic stomach emptying, and ventilation of localized lung regions have been studied successfully suggesting further applications in monitoring of gastric acid secretion, artificial respiration, bladder emptying, etc. Multi-frequency FIM may help identify some diseases and disorders including certain cancers. FIM, being much simpler and having less number of electrodes, appears to have the potential to replace EIT for applications involving large and shallow organs. An enhancement of 6-electrode FIM led to Pigeon Hole Imaging (PHI) in a square matrix through backprojection in two orthogonal directions, good for localising of one or two well separated objects.

  12. Evaluation of indirect impedance for measuring microbial growth in complex food matrices.

    PubMed

    Johnson, N; Chang, Z; Bravo Almeida, C; Michel, M; Iversen, C; Callanan, M

    2014-09-01

    The suitability of indirect impedance to accurately measure microbial growth in real food matrices was investigated. A variety of semi-solid and liquid food products were inoculated with Bacillus cereus, Listeria monocytogenes, Staphylococcus aureus, Lactobacillus plantarum, Pseudomonas aeruginosa, Escherichia coli, Salmonella enteriditis, Candida tropicalis or Zygosaccharomyces rouxii and CO2 production was monitored using a conductimetric (Don Whitely R.A.B.I.T.) system. The majority (80%) of food and microbe combinations produced a detectable growth signal. The linearity of conductance responses in selected food products was investigated and a good correlation (R(2) ≥ 0.84) was observed between inoculum levels and times to detection. Specific growth rate estimations from the data were sufficiently accurate for predictive modeling in some cases. This initial evaluation of the suitability of indirect impedance to generate microbial growth data in complex food matrices indicates significant potential for the technology as an alternative to plating methods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Improved electrode positions for local impedance measurements in the lung-a simulation study.

    PubMed

    Orschulik, Jakob; Petkau, Rudolf; Wartzek, Tobias; Hochhausen, Nadine; Czaplik, Michael; Leonhardt, Steffen; Teichmann, Daniel

    2016-12-01

    Impedance spectroscopy can be used to analyze the dielectric properties of various materials. In the biomedical domain, it is used as bioimpedance spectroscopy (BIS) to analyze the composition of body tissue. Being a non-invasive, real-time capable technique, it is a promising modality, especially in the field of lung monitoring. Unfortunately, up to now, BIS does not provide any regional lung information as the electrodes are usually placed in hand-to-hand or transthoracic configurations. Even though transthoracic electrode configurations are in general capable of monitoring the lung, no focusing to specific regions is achieved. In order to resolve this issue, we use a finite element model (FEM) of the human body to study the effect of different electrode configurations on measured BIS data. We present evaluation results and show suitable electrode configurations for eight lung regions. We show that, using these optimized configurations, BIS measurements can be focused to desired regions allowing local lung analysis.

  14. A sapphire loaded TE011 cavity for surface impedance measurements: design, construction, and commissioning status

    SciTech Connect

    L. Phillips; G. K. Davis; J. R. Delayen

    2005-07-10

    In order to measure the superconducting surface properties of niobium that are of interest to SRF applications, a facility which utilizes a Nb cavity operating in the TE011 mode at 7.65 GHz which provides a well-defined RF field on a disk shaped sample has been designed and fabricated. The RF losses due to the sample's surface impedance are determined by using a calorimetric technique. The system has the capability to measure such properties as Rs,(T), and penetration depth, which can then be correlated with surface properties and preparation processes. The design, fabrication, and results from initial commissioning operations will bemore » discussed, along with the near term sample evaluation program.« less

  15. An HF coaxial bridge for measuring impedance ratios up to 1 MHz

    NASA Astrophysics Data System (ADS)

    Kucera, J.; Sedlacek, R.; Bohacek, J.

    2012-08-01

    A four-terminal pair coaxial ac bridge developed for calibrating both resistance and capacitance ratios and working in the frequency range from 100 kHz up to 1 MHz is described. A reference inductive voltage divider (IVD) makes it possible to calibrate ratios 1:1 and 10:1 with uncertainty of a few parts in 105. The IVD is calibrated by means of a series-parallel capacitance device (SPCD). Use of the same ac bridge with minimal changes for calibrating the SPCD, IVD and unknown impedances simplifies the whole calibration process. The bridge balance conditions are fulfilled with simple capacitance and resistance decades and by injecting voltage supplied from the auxiliary direct digital synthesizer. Bridge performance was checked on the basis of resistance ratio measurements and also capacitance ratio measurements.

  16. Estimation of Metabolism Characteristics for Heat-Injured Bacteria Using Dielectrophoretic Impedance Measurement Method

    NASA Astrophysics Data System (ADS)

    Amako, Eri; Enjoji, Takaharu; Uchida, Satoshi; Tochikubo, Fumiyoshi

    Constant monitoring and immediate control of fermentation processes have been required for advanced quality preservation in food industry. In the present work, simple estimation of metabolic states for heat-injured Escherichia coli (E. coli) in a micro-cell was investigated using dielectrophoretic impedance measurement (DEPIM) method. Temporal change in the conductance between micro-gap (ΔG) was measured for various heat treatment temperatures. In addition, the dependence of enzyme activity, growth capacity and membrane situation for E. coli on heat treatment temperature was also analyzed with conventional biological methods. Consequently, a correlation between ΔG and those biological properties was obtained quantitatively. This result suggests that DEPIM method will be available for an effective monitoring technique for complex change in various biological states of microorganisms.

  17. A new application of electrical impedance spectroscopy for measuring glucose metabolism: a phantom study

    NASA Astrophysics Data System (ADS)

    Dhurjaty, Sreeram; Qiu, Yuchen; Tan, Maxine; Liu, Hong; Zheng, Bin

    2015-03-01

    Glucose metabolism relates to biochemical processes in living organisms and plays an important role in diabetes and cancer-metastasis. Although many methods are available for measuring glucose metabolism-activities, from simple blood tests to positron emission tomography, currently there is no robust and affordable device that enables monitoring of glucose levels in real-time. In this study we tested feasibility of applying a unique resonance-frequency based electronic impedance spectroscopy (REIS) device that has been, recently developed to measure and monitor glucose metabolism levels using a phantom study. In this new testing model, a multi-frequency electrical signal sequence is applied and scanned through the subject. When the positive reactance of an inductor inside the device cancels out the negative reactance of the capacitance of the subject, the electrical impedance reaches a minimum value and this frequency is defined as the resonance frequency. The REIS system has a 24-bit analog-to-digital signal convertor and a frequency-resolution of 100Hz. In the experiment, two probes are placed inside a 100cc container initially filled with distilled water. As we gradually added liquid-glucose in increments of 1cc (250mg), we measured resonance frequencies and minimum electrical signal values (where A/D was normalized to a full scale of 1V). The results showed that resonance frequencies monotonously decreased from 243kHz to 178kHz, while the minimum voltages increased from 405mV to 793mV as the added amount of glucose increased from 0 to 5cc. The study demonstrated the feasibility of applying this new REIS technology to measure and/or monitor glucose levels in real-time in future.

  18. Quantitative measurements of nanoscale permittivity and conductivity using tuning-fork-based microwave impedance microscopy

    SciTech Connect

    Wu, Xiaoyu; Hao, Zhenqi; Wu, Di

    Here, we report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS 2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-fieldmore » microwave imaging with small distance modulation.« less

  19. Quantitative measurements of nanoscale permittivity and conductivity using tuning-fork-based microwave impedance microscopy

    DOE PAGES

    Wu, Xiaoyu; Hao, Zhenqi; Wu, Di; ...

    2018-04-01

    Here, we report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS 2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-fieldmore » microwave imaging with small distance modulation.« less

  20. Characterizing a porous road pavement using surface impedance measurement: a guided numerical inversion procedure.

    PubMed

    Benoit, Gaëlle; Heinkélé, Christophe; Gourdon, Emmanuel

    2013-12-01

    This paper deals with a numerical procedure to identify the acoustical parameters of road pavement from surface impedance measurements. This procedure comprises three steps. First, a suitable equivalent fluid model for the acoustical properties porous media is chosen, the variation ranges for the model parameters are set, and a sensitivity analysis for this model is performed. Second, this model is used in the parameter inversion process, which is performed with simulated annealing in a selected frequency range. Third, the sensitivity analysis and inversion process are repeated to estimate each parameter in turn. This approach is tested on data obtained for porous bituminous concrete and using the Zwikker and Kosten equivalent fluid model. This work provides a good foundation for the development of non-destructive in situ methods for the acoustical characterization of road pavements.

  1. Determination of Cole-Cole parameters using only the real part of electrical impedivity measurements.

    PubMed

    Miranda, David A; Rivera, S A López

    2008-05-01

    An algorithm is presented to determine the Cole-Cole parameters of electrical impedivity using only measurements of its real part. The algorithm is based on two multi-fold direct inversion methods for the Cole-Cole and Debye equations, respectively, and a genetic algorithm for the optimization of the mean square error between experimental and calculated data. The algorithm has been developed to obtain the Cole-Cole parameters from experimental data, which were used to screen cervical intra-epithelial neoplasia. The proposed algorithm was compared with different numerical integrations of the Kramers-Kronig relation and the result shows that this algorithm is the best. A high immunity to noise was obtained.

  2. Quantitative measurements of nanoscale permittivity and conductivity using tuning-fork-based microwave impedance microscopy

    NASA Astrophysics Data System (ADS)

    Wu, Xiaoyu; Hao, Zhenqi; Wu, Di; Zheng, Lu; Jiang, Zhanzhi; Ganesan, Vishal; Wang, Yayu; Lai, Keji

    2018-04-01

    We report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-field microwave imaging with small distance modulation.

  3. 3D modelling of the human thorax for ventilation distribution measured through electrical impedance tomography

    NASA Astrophysics Data System (ADS)

    Fan, W. R.; Wang, H. X.

    2010-11-01

    Thoracic electrical impedance tomography (EIT) aims to reconstruct a cross-sectional image of the internal spatial distribution of conductivity from electrical measurements made by injecting small alternating currents via an electrode array placed on the surface of the thorax. It is a non-invasive, radiation-free monitoring technique. In this paper, true 3D thorax models with conductivity distribution or complex conductivity distribution under different ARDS conditions are built up in comparison with the 2.5D ones, and EIT-derived numeric indices are also employed for evaluation of the lung ventilation. The purpose of this paper is to study different effects of different thorax models with either conductivity or complex conductivity on the reconstructed images and ventilation indices.

  4. Design and test of voltage and current probes for EAST ICRF antenna impedance measurement

    NASA Astrophysics Data System (ADS)

    Jianhua, WANG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Shuai, YUAN; Xinjun, ZHANG; Hua, YANG; Chengming, QIN; Yan, CHENG; Yuqing, YANG; Guillaume, URBANCZYK; Lunan, LIU; Jian, CHENG

    2018-04-01

    On the experimental advanced superconducting tokamak (EAST), a pair of voltage and current probes (V/I probes) is installed on the ion cyclotron radio frequency transmission lines to measure the antenna input impedance, and supplement the conventional measurement technique based on voltage probe arrays. The coupling coefficients of V/I probes are sensitive to their sizes and installing locations, thus they should be determined properly to match the measurement range of data acquisition card. The V/I probes are tested in a testing platform at low power with various artificial loads. The testing results show that the deviation of coupling resistance is small for loads R L > 2.5 Ω, while the resistance deviations appear large for loads R L < 1.5 Ω, which implies that the power loss cannot be neglected at high VSWR. As the factors that give rise to the deviation of coupling resistance calculation, the phase measurement error is the more significant factor leads to deleterious results rather than the amplitude measurement error. To exclude the possible ingredients that may lead to phase measurement error, the phase detector can be calibrated in steady L-mode scenario and then use the calibrated data for calculation under H-mode cases in EAST experiments.

  5. An impedance bridge measuring the capacitance ratio in the high frequency range up to 1 MHz

    NASA Astrophysics Data System (ADS)

    Bee Kim, Dan; Kew Lee, Hyung; Kim, Wan-Seop

    2017-02-01

    This paper describes a 2-terminal-pair impedance bridge, measuring the capacitance ratio in the high frequency range up to 1 MHz. The bridge was configured with two voltage sources and a phase control unit which enabled the bridge balance by synchronizing the voltage sources with an enhanced phase resolution. Without employing the transformers such as inductive voltage divider, injection and detection transformers, etc, the bridge system is quite simple to set up, and the balance procedure is quick and easy. Using this dual-source coaxial bridge, the 1:1 and 10:1 capacitance ratios were measured with 1 pF-1 nF capacitors in the frequency range from 1 kHz to 1 MHz. The measurement values obtained by the dual-source bridge were then compared with reference values measured using a commercial precision capacitance bridge of AH2700A, the Z-matrix method developed by ourselves, and the 4-terminal-pair coaxial bridge by the Czech Metrological Institute. All the measurements agreed within the reference uncertainty range of an order of 10-6-10-5, proving the bridge ability as a trustworthy tool for measuring the capacitance ratio in the high frequency range.

  6. Equivalent circuit parameters of nickel/metal hydride batteries from sparse impedance measurements

    NASA Astrophysics Data System (ADS)

    Nelatury, Sudarshan Rao; Singh, Pritpal

    In a recent communication, a method for extracting the equivalent circuit parameters of a lead acid battery from sparse (only three) impedance spectroscopy observations at three different frequencies was proposed. It was based on an equivalent circuit consisting of a bulk resistance, a reaction resistance and a constant phase element (CPE). Such a circuit is a very appropriate model of a lead-acid cell at high state of charge (SOC). This paper is a sequel to it and presents an application of it in case of nickel/metal hydride (Ni/MH) batteries, which also at high SOC are represented by the same circuit configuration. But when the SOC of a Ni/MH battery under interrogation goes low, The EIS curve has a positive slope at the low frequency end and our technique yields complex values for the otherwise real circuit parameters, suggesting the need for additional elements in the equivalent circuit and a definite relationship between parameter consistency and SOC. To improvise the previous algorithm, in order that it works reasonably well at both high and low SOCs, we propose three more measurements—two at very low frequencies to include the Warburg response and one at a high frequency to model the series inductance, in addition to the three in the mid frequency band—totally six measurements. In most of the today's instrumentation, it is the user who should choose the circuit configuration and the number of frequencies where impedance should be measured and the accompanying software performs data fitting by complex nonlinear least squares. The proposed method has built into it an SOC-based decision-making capability—both to choose the circuit configuration and to estimate the values of the circuit elements.

  7. High frequency electromagnetic impedance measurements for characterization, monitoring and verification efforts. 1998 annual progress report

    SciTech Connect

    Lee, K.H.; Pellerin, L.; Becker, A.

    1998-06-01

    'Non-invasive, high-resolution imaging of the shallow subsurface is needed for delineation of buried waste, detection of unexploded ordinance, verification and monitoring of containment structures, and other environmental applications. Electromagnetic measurements at frequencies between 1 and 100 MHz are important for such applications, because the induction number of many targets is small due, and the ability to determine the dielectric permittivity in addition to electrical conductivity of the subsurface is possible. Earlier workers were successful in developing systems for detecting anomalous areas, but no quantifiable information was accurately determined. For high resolution imaging, accurate measurements are necessary so the field datamore » can be mapped into the space of the subsurface parameters. The authors are developing a non-invasive method for accurately imaging the electrical conductivity and dielectric permittivity of the shallow subsurface using the plane wave impedance approach, known as the magnetotelluric (MT) method at low frequencies. Electric and magnetic sensors are being tested in a known area against theoretical predictions, thereby insuring that the data collected with the high-frequency impedance (HFI) system will support high-resolution, multi-dimensional imaging techniques. The summary of the work to date is divided into three sections: equipment procurement, instrumentation, and theoretical developments. For most earth materials, the frequency range from 1 to 100 MHz encompasses a very difficult transition zone between the wave propagation of displacement currents and the diffusive behavior of conduction currents. Test equipment, such as signal generators and amplifiers, does not cover the entire range except at great expense. Hence the authors have divided the range of investigation into three sub-ranges: 1--10 MHz, 10--30 MHz, and 30--100 MHz. Results to date are in the lowest frequency range of 1--10 MHz. Even though conduction

  8. Evaluation of Grounding Impedance of a Complex Lightning Protective System Using Earth Ground Clamp Measurements and ATP Modeling

    NASA Technical Reports Server (NTRS)

    Mata, Carlos T.; Rakov, V. A.; Mata, Angel G.

    2010-01-01

    A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulators installed atop three towers in a triangular configuration. A total of nine downconductors (each about 250 meters long, on average) are connected to the catenary wire system. Each of the nine downconductors is connected to a 7.62-meter radius circular counterpoise conductor with six equally spaced 6-meter long vertical grounding rods. Grounding requirements at LC39B call for all underground and above ground metallic piping, enclosures, raceways, and cable trays, within 7.62 meters of the counterpoise, to be bounded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways, and cable trays that run in multiple direction around LC39B. The complexity of this grounding system makes the fall of potential method, which uses multiple metallic rods or stakes, unsuitable for measuring the grounding impedances of the downconductors. To calculate the downconductors grounding impedance, an Earth Ground Clamp (a stakeless grounding resistance measuring device) and a LPS Alternative Transient Program (ATP) model are used. The Earth Ground Clamp is used to measure the loop impedance plus the grounding impedance of each downconductor and the ATP model is used to calculate the loop impedance of each downconductor circuit. The grounding impedance of the downconductors is then calculated by subtracting the ATP calculated loop impedances from the Earth Ground Clamp measurements.

  9. Biomedical engineering meets acupuncture - development of a miniaturized 48-channel skin impedance measurement system for needle and laser acupuncture

    PubMed Central

    2010-01-01

    Background Due to controversially discussed results in scientific literature concerning changes of electrical skin impedance before and during acupuncture a new measurement system has been developed. Methods The prototype measures and analyzes the electrical skin impedance computer-based and simultaneously in 48 channels within a 2.5×3.5 cm matrix. Preliminary measurements in one person were performed using metal needle and violet laser (405 nm) acupuncture at the acupoint Kongzui (LU6). The new system is an improvement on devices previously developed by other researchers for this purpose. Results Skin impedance in the immediate surroundings of the acupoint was lowered reproducibly following needle stimulation and also violet laser stimulation. Conclusions A new instrumentation for skin impedance measurements is presented. The following hypotheses suggested by our results will have to be tested in further studies: Needle acupuncture causes significant, specific local changes of electrical skin impedance parameters. Optical stimulation (violet laser) at an acupoint causes direct electrical biosignal changes. PMID:21092296

  10. Electrical properties of rat muscle after sciatic nerve injury: Impact on surface impedance measurements assessed via finite element analysis

    NASA Astrophysics Data System (ADS)

    Ahad, M. A.; Rutkove, S. B.

    2010-04-01

    Tetrapolar surface electrical impedance methods are sensitive to changes in muscle status and can therefore provide a means for studying neuromuscular disease noninvasively. In order to better understand the relationship between surface impedance measurements and the actual muscle electrical properties, we performed measurements on 20 adult Wistar rats, 8 of which underwent sciatic nerve crush. Surface impedance measurements were performed on the left hind limb both before injury and out to 2 weeks after injury. In addition, both normal and sciatic crush animals were sacrificed and the dielectric properties of the extracted gastrocnemius muscle measured. We found that 50 kHz conductivities were greater in the animals that underwent crush than in the animals that did not. The permittivities in both directions, however, showed non-significant differences. In order to analyze the effect of these changes as well as the accompanying reduction in muscle volume, a finite element model of the hind limb was developed based on computerized tomographic imaging. The model successfully predicted the surface impedance values in the animals after crush injury and, by its inverse application, may be used to help determine the underlying electrical properties of muscle in various neuromuscular diseases based on surface impedance data.

  11. Parametric electrical impedance tomography for measuring bone mineral density in the pelvis using a computational model.

    PubMed

    Kimel-Naor, Shani; Abboud, Shimon; Arad, Marina

    2016-08-01

    Osteoporosis is defined as bone microstructure deterioration resulting a decrease of bone's strength. Measured bone mineral density (BMD) constitutes the main tool for Osteoporosis diagnosis, management, and defines patient's fracture risk. In the present study, parametric electrical impedance tomography (pEIT) method was examined for monitoring BMD, using a computerized simulation model and preliminary real measurements. A numerical solver was developed to simulate surface potentials measured over a 3D computerized pelvis model. Varying cortical and cancellous BMD were simulated by changing bone conductivity and permittivity. Up to 35% and 16% change was found in the real and imaginary modules of the calculated potential, respectively, while BMD changes from 100% (normal) to 60% (Osteoporosis). Negligible BMD relative error was obtained with SNR>60 [dB]. Position changes errors indicate that for long term monitoring, measurement should be taken at the same geometrical configuration with great accuracy. The numerical simulations were compared to actual measurements that were acquired from a healthy male subject using a five electrodes belt bioimpedance device. The results suggest that pEIT may provide an inexpensive easy to use tool for frequent monitoring BMD in small clinics during pharmacological treatment, as a complementary method to DEXA test. Copyright © 2016. Published by Elsevier Ltd.

  12. Transfer impedance measurements of the space shuttle Solid Rocket Motor (SRM) joints, wire meshes and a carbon graphite motor case

    NASA Technical Reports Server (NTRS)

    Papazian, Peter B.; Perala, Rodney A.; Curry, John D.; Lankford, Alan B.; Keller, J. David

    1988-01-01

    Using three different current injection methods and a simple voltage probe, transfer impedances for Solid Rocket Motor (SRM) joints, wire meshes, aluminum foil, Thorstrand and a graphite composite motor case were measured. In all cases, the surface current distribution for the particular current injection device was calculated analytically or by finite difference methods. The results of these calculations were used to generate a geometric factor which was the ratio of total injected current to surface current density. The results were validated in several ways. For wire mesh measurements, results showed good agreement with calculated results for a 14 by 18 Al screen. SRM joint impedances were independently verified. The filiment wound case measurement results were validated only to the extent that their curve shape agrees with the expected form of transfer impedance for a homogeneous slab excited by a plane wave source.

  13. Assessing risk of thyroid cancer using resonance-frequency based electrical impedance measurements

    NASA Astrophysics Data System (ADS)

    Zheng, Bin; Tublin, Mitchell E.; Lederman, Dror; Klym, Amy H.; Brown, Erica D.; Gur, David

    2011-03-01

    The incidence of thyroid cancer has risen faster than many malignancies and has nearly doubled in the USA over the past 30 years. Palpable nodules and subclinical nodules detected by imaging are found in a large percentage of the USA population. Most of these (.>95%) are fortunately benign. This vast reservoir of nodules makes the detection and diagnosis of thyroid cancer a diagnostic dilemma. Ultrasound guided Fine Needle Aspiration Biopsy (FNAB) is excellent for triaging patients but up to 25% of FNABs are inconclusive. As a result, definitive diagnosis is often only possible with a diagnostic lobectomy; many thousands of these are performed in the USA annually for ultimately benign disease. It would be extremely beneficial if we could develop a non-invasive procedure that could assist the diagnostician in reliably predicting the likelihood of malignancy of otherwise indeterminate thyroid nodules, thereby reducing the number of these "exploratory/diagnostic" lobectomies performed under general anesthesia. Electrical Impedance Spectroscopy (EIS) was considered as a possible approach to address this problem. However, the diagnostic accuracy of EIS is too low for routine clinical use to date. In our group, we developed a substantially modified technology termed Resonance-frequency Electrical Impedance Spectroscopy (REIS), which yields usable information for classifying risk of having breast abnormalities. We preliminarily applied REIS to measure signals on participants having thyroid nodules aiming to assess whether we can assist in improving diagnosis of indeterminate thyroid nodules. In this study we present a new multi-probe based REIS device specifically designed for the assessment of indeterminate thyroid nodules. Our preliminary assessment presented here demonstrates the feasibility of using this proposed REIS device in a busy tertiary care center.

  14. Non-contact multi-frequency magnetic induction spectroscopy system for industrial-scale bio-impedance measurement

    NASA Astrophysics Data System (ADS)

    O'Toole, M. D.; Marsh, L. A.; Davidson, J. L.; Tan, Y. M.; Armitage, D. W.; Peyton, A. J.

    2015-03-01

    Biological tissues have a complex impedance, or bio-impedance, profile which changes with respect to frequency. This is caused by dispersion mechanisms which govern how the electromagnetic field interacts with the tissue at the cellular and molecular level. Measuring the bio-impedance spectra of a biological sample can potentially provide insight into the sample’s properties and its cellular structure. This has obvious applications in the medical, pharmaceutical and food-based industrial domains. However, measuring the bio-impedance spectra non-destructively and in a way which is practical at an industrial scale presents substantial challenges. The low conductivity of the sample requires a highly sensitive instrument, while the demands of industrial-scale operation require a fast high-throughput sensor of rugged design. In this paper, we describe a multi-frequency magnetic induction spectroscopy (MIS) system suitable for industrial-scale, non-contact, spectroscopic bio-impedance measurement over a bandwidth of 156 kHz-2.5 MHz. The system sensitivity and performance are investigated using calibration and known reference samples. It is shown to yield rapid and consistently sensitive results with good long-term stability. The system is then used to obtain conductivity spectra of a number of biological test samples, including yeast suspensions of varying concentration and a range of agricultural produce, such as apples, pears, nectarines, kiwis, potatoes, oranges and tomatoes.

  15. Method to detect the end-point for PCR DNA amplification using an ionically labeled probe and measuring impedance change

    DOEpatents

    Miles, Robin R [Danville, CA; Belgrader, Phillip [Severna Park, MD; Fuller, Christopher D [Oakland, CA

    2007-01-02

    Impedance measurements are used to detect the end-point for PCR DNA amplification. A pair of spaced electrodes are located on a surface of a microfluidic channel and an AC or DC voltage is applied across the electrodes to produce an electric field. An ionically labeled probe will attach to a complementary DNA segment, and a polymerase enzyme will release the ionic label. This causes the conductivity of the solution in the area of the electrode to change. This change in conductivity is measured as a change in the impedance been the two electrodes.

  16. Measurement of nutritional status in simulated microgravity by bioelectrical impedance spectroscopy

    NASA Technical Reports Server (NTRS)

    Bartok, Cynthia; Atkinson, Richard L.; Schoeller, Dale A.

    2003-01-01

    The potential of bioelectrical impedance spectroscopy (BIS) for assessing nutritional status in spaceflight was tested in two head-down-tilt bed-rest studies. BIS-predicted extracellular water (ECW), intracellular water (ICW), and total body water (TBW) measured using knee-elbow electrode placement were compared with deuterium and bromide dilution (DIL) volumes in healthy, 19- to 45-yr-old subjects. BIS was accurate during 44 h of head-down tilt with mean differences (BIS - DIL) of 0-0.1 kg for ECW, 0.3-0.5 for ICW, and 0.4-0.6 kg for TBW (n = 28). At 44 h, BIS followed the within-individual change in body water compartments with a relative prediction error (standard error of the estimate/baseline volume) of 2.0-3.6% of water space. In the second study, BIS did not detect an acute decrease (-1.41 +/- 0.91 kg) in ICW secondary to 48 h of a protein-free, 800 kcal/day diet (n = 18). BIS's insensitivity to ICW losses may be because they were predominantly (65%) localized to the trunk and/or because there was a general failure of BIS to measure ICW independently of ECW and TBW. BIS may have potential for measuring nutritional status during spaceflight, but its limitations in precision and insensitivity to acute ICW changes warrant further validation studies.

  17. Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry.

    PubMed

    Abrahamsen, B; Hansen, T B; Høgsberg, I M; Pedersen, F B; Beck-Nielsen, H

    1996-01-01

    Dual X-ray absorptiometry (DXA) performs noninvasive assessment of bone and soft tissue with high precision. However, soft tissue algorithms assume that 73.2% of the lean body mass is water, a potential source of error in fluid retention. We evaluated DXA (model QDR-2000; Hologic Inc, Waltham, MA), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined by the reduction in gravimetric weight (r = 0.975, P < 0.0001; SEE: 233 g), whereas BIA was considerably less accurate in assessing FFM reductions (r = 0.66, P < 0.01; SEE: 757 g). Lumbar bone mineral density (BMD) was unaffected by dialysis, as were whole-body fat and BMD. Whole-body bone mineral content, however, was estimated to be 0.6% lower after dialysis. None of the simple anthropometric measurements correlated significantly with the reduction in FFM. In an unmodified clinical setting, DXA appears to be superior to other simple noninvasive methods for determining body composition, particularly when the emphasis is on repeated measurements.

  18. Measured and calculated acoustic attenuation rates of tuned resonator arrays for two surface impedance distribution models with flow

    NASA Technical Reports Server (NTRS)

    Parrott, Tony L.; Abrahamson, A. Louis; Jones, Michael G.

    1988-01-01

    An experiment was performed to validate two analytical models for predicting low frequency attenuation of duct liner configurations built from an array of seven resonators that could be individually tuned via adjustable cavity depths. These analytical models had previously been developed for high frequency aero-engine inlet duct liner design. In the low frequency application, the liner surface impedance distribution is unavoidably spatially varying by virtue of available fabrication techniques. The characteristic length of this spatial variation may be a significant fraction of the acoustic wavelength. Comparison of measured and predicted attenuation rates and transmission losses for both modal decomposition and finite element propagation models were in good to excellent agreement for a test frequency range that included the first and second cavity resonance frequencies. This was true for either of two surface impedance distribution modeling procedures used to simplify the impedance boundary conditions. In the presence of mean flow, measurements revealed a fine scale structure of acoustic hot spots in the attenuation and phase profiles. These details were accurately predicted by the finite element model. Since no impedance changes due to mean flow were assumed, it is concluded that this fine scale structure was due to convective effects of the mean flow interacting with the surface impedance nonuniformities.

  19. Relationship between frequency and impedance change in an infusion rate measurement system employing a capacitance sensor - biomed 2011.

    PubMed

    Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Hahn, Allen W; Caldwell, W Morton

    2011-01-01

    We have been searching for a suitable frequency range for an electrical impedance measurement infusion solution drip monitoring system, which we have previously reported. This electrical impedance, which is formed between two electrodes wrapped around the infusion supply polyvinyl-chloride tube and around the drip chamber, is changed by the growth and fall of each drop of fluid. Thus, the drip rate can be detected by measuring this impedance. However, many different kinds of infusion solutions such as glucose, amino acid, soya oil, and lactated Ringer’s solution are used in hospitals and care facilities. Therefore, it was necessary to find a suitable frequency for driving the capacitance-change sensor with a wide range of infusion solutions. In this study, the sensor electrical impedance change of 16 infusion solutions was measured from 1 kHz up to 1 MHz. The drip impedance produced by 5% glucose solution, 10% glucose solution and soya oil indicated the maximum sensor output change at 10 kHz, 20 kHz, and 70 kHz, respectively. The other 13 infusion solutions increased up to 10 kHz, and were constant from 10 kHz to 1 MHz. However, the growth, fall, and drip rate of the drops of all the infusion solutions were monitored by measuring the impedance change from 10 kHz to 30 kHz. Our experimental results indicated that most suitable excitation range for the infusion monitoring system is from 10 kHz to 30 kHz. Thus, we can now “fine-tune” the system for optimal sensing.

  20. Comparison of hydrostatic weighing and bioelectric impedance measurements in determining body composition pre- and postdehydration.

    PubMed

    Pearman, P; Hunter, G; Hendricks, C; O'Sullivan, P

    1989-01-01

    This study investigated the effect of dehydration on measurements of body composition by hydrostatic weighing (HW) and bioelectric impedance analysis (BIA). Ten endurance-trained male athletes between the ages of 18 and 42 years performed an endurance training session consisting of running until body weight was reduced by approximately 3%. Body composition was determined prior to exercise and immediately after exercise by HW and BIA techniques. A high correlation existed between pre- and postdehydration for both HW and BIA. Validity coefficients between HW and BIA were moderate (predehydration 0.85 and postdehydration 0.82). In addition, BIA percent fat was 3.5% higher than HW percent fat. The BIA revealed a mean loss of 2.1% fat BIA and only 0.9% fat HW after approximately 45 minutes of exercise. BIA also showed an increase in percent body water (mean = 2.6%) in all 10 subjects after dehydration. There are indications that BIA, with its present equational configuration, is measuring something other than lean body weight. J Orthop Sports Phys Ther 1989;10(11):451-455.

  1. Microengineered Conductive Elastomeric Electrodes for Long-Term Electrophysiological Measurements with Consistent Impedance under Stretch

    PubMed Central

    Hu, Dinglong; Cheng, Tin Kei; Xie, Kai; Lam, Raymond H. W.

    2015-01-01

    In this research, we develop a micro-engineered conductive elastomeric electrode for measurements of human bio-potentials with the absence of conductive pastes. Mixing the biocompatible polydimethylsiloxane (PDMS) silicone with other biocompatible conductive nano-particles further provides the material with an electrical conductivity. We apply micro-replica mold casting for the micro-structures, which are arrays of micro-pillars embedded between two bulk conductive-PDMS layers. These micro-structures can reduce the micro-structural deformations along the direction of signal transmission; therefore the corresponding electrical impedance under the physical stretch by the movement of the human body can be maintained. Additionally, we conduct experiments to compare the electrical properties between the bulk conductive-PDMS material and the microengineered electrodes under stretch. We also demonstrate the working performance of these micro-engineered electrodes in the acquisition of the 12-lead electrocardiographs (ECG) of a healthy subject. Together, the presented gel-less microengineered electrodes can provide a more convenient and stable bio-potential measurement platform, making tele-medical care more achievable with reduced technical barriers for instrument installation performed by patients/users themselves. PMID:26512662

  2. Optimization of impedance spectroscopy techniques for measuring cutaneous micropore formation after microneedle treatment in an elderly population.

    PubMed

    Kelchen, Megan N; Holdren, Grant O; Farley, Matthew J; Zimmerman, M Bridget; Fairley, Janet A; Brogden, Nicole K

    2014-12-01

    The objective of this study was to optimize a reproducible impedance spectroscopy method in elderly subjects as a means to evaluate the effects of microneedles on aging skin. Human volunteers were treated with microneedles at six sites on the upper arm. Repeated impedance measurements were taken pre- and post-microneedle insertion. Two electrode types were evaluated (dry vs. gel), using either light or direct pressure to maintain contact between the electrode and skin surface. Transepidermal water loss (TEWL) was measured as a complementary technique. Five control subjects and nine elderly subjects completed the study. Microneedle insertion produced a significant decrease in impedance from baseline in all subjects (p < 0.05, regardless of electrode type or pressure application), confirming micropore formation. This was supported by a complementary significant increase in TEWL (p < 0.05). The gel*direct condition produced the lowest variability between measurements, as demonstrated by a coefficient of variation of 3.8% and 3.5% (control and elderly subjects, respectively). This was lower than variation between TEWL measurements at the same sites: 19.8% and 21.6% (control and elderly subjects, respectively). Impedance spectroscopy reproducibly measures micropore formation in elderly subjects, which will be essential for future studies describing microneedle-assisted transdermal delivery in aging populations.

  3. Measuring acoustic impedances using a semi-infinite waveguide reference: Applications to wind instruments and vocal tracts

    NASA Astrophysics Data System (ADS)

    Wolfe, Joe; Smith, John; Tann, John; France, Ryan

    2002-11-01

    Acoustic pressures may generally be measured with much greater sensitivity, dynamic range, and frequency response than acoustic currents. Consequently, most measurements of acoustic impedance consist of comparison with standard impedances. The method reported here uses a semi-infinite waveguide as the reference because its impedance is purely resistive, frequency independent and accurately known, independent of theories of the boundary layer. Waveguides are effectively infinite for pulses shorter than the echo return time, or if the attenuation due to wall losses (typically 80 dB) exceeds the dynamic range of the experiment. The measurement signal from a high output impedance source is calibrated to have Fourier components proportional to fn, where n may be 1 for convenience or chosen to improve the signal:noise ratio. The method has been used on diverse systems over the range 50 Hz to 13 kHz. When applied to systems with simple geometries, the technique yields results with a little higher wall losses than those expected from the calculations of Rayleigh and Benade. Discontinuities introduce further losses as well as the expected departures from simple one-dimensional models. Measurements on musical wind instruments and on the human vocal tract are reported. [Work supported by the Australian Research Council.

  4. Electron Density Measurement on JUICE Mission by Mutual Impedance Technique: MIME Instrument as a Part of RPWI Consortium

    NASA Astrophysics Data System (ADS)

    Rauch, J. L.; Henri, P.; Wahlund, J. E.; Le Duff, O.; Sene, O.; Colin, F.; Lagoutte, D.; Gilet, N.; Ahlen, L.; Bergman, J.; Gill, R.; Puccio, W.

    2017-09-01

    Mutual Impedance MEasurements (MIME) instrument is a part of the Radio Wave Plasma Investigation (RPWI) consortium which has been selected by European Space Agency (ESA) on the nest planetary mission JJUpiter ICy moons Exploer (JUICE) for a launch in 2022. The goals are to explore Jupiter and its potentially habitable icy moons and to study its plasma environment. Impedance probes, which are well known in geophysical prospection, in particular for ground permittivity investigations, have been successfully transposed to space plasmas diagnostic. Transmitting and receiving electrodes are used for measuring on open circuit the dynamic impedance of the system at several fixed frequencies over a range that includes characteristic frequencies of the ambient plasma. The measurements are then interpreted using a suitable theory and the values of plasma parameters, such as the electron density and possibly the temperature of the plasma can be deduced. To show how powerful this technique is, results obtained in the Earth's plasmasphere by the mutual impedance probe onboard ROSETTA are presented as example. MIME instrument proposal is then described and its ability to make valuable measurements in the Jupiter space environment and in particular around Europe, Callisto and Ganymede is investigated..

  5. Electrochemical impedance spectroscopy (EIS) as a tool for measuring corrosion of polymer-coated fasteners used in treated wood

    Treesearch

    Samuel L. Zelinka; Lorraine Ortiz-Candelaria; Donald S. Stone; Douglas R. Rammer

    2009-01-01

    Currently, many of the polymer-coated fasteners on the market are designed for improved corrosion performance in treated wood; yet, there is no way to evaluate their corrosion performance. In this study, a common technique for measuring the corrosion performance of polymer-coated metals, electrochemical impedance spectroscopy (EIS), was used to evaluate commercial...

  6. Propagation of sound through the Earth's atmosphere. 1: Measurement of sound absorption in the air: 2: Measurement of ground impedance

    NASA Technical Reports Server (NTRS)

    Meredith, R. W.; Becher, J.

    1981-01-01

    Parts were fabricated for the acoustic ground impedance meter and the instrument was tested. A rubber hose was used to connect the resonator neck to the chamber in order to suppress vibration from the volume velocity source which caused chatter. An analog to digital converter was successfully hardwired to the computer detection system. The cooling system for the resonant tube was modified to use liquid nitrogen cooling. This produced the required temperature for the tube, but the temperature gradients within each of the four tube sections reached unacceptable levels. Final measurements of the deexcitation of nitrogen by water vapor indicate that the responsible physical process is not the direct vibration-translation energy transfer, but is a vibration-vibration energy transfer.

  7. Bioelectrical impedance vector analysis (BIVA) for measuring the hydration status in young elite synchronized swimmers

    PubMed Central

    Carrasco-Marginet, Marta; Castizo-Olier, Jorge; Rodríguez-Zamora, Lara; Iglesias, Xavier; Rodríguez, Ferran A.; Chaverri, Diego; Brotons, Daniel

    2017-01-01

    Purpose The assessment of body hydration is a complex process, and no measurement is valid for all situations. Bioelectrical impedance vector analysis (BIVA) has emerged as a relatively novel technique for assessing hydration status in sports. We applied BIVA a) to determine hydration changes evoked by an intense synchronized swimming (SS) training session; b) to characterize the sample of young elite swimmers in relation with a nonathletic reference population; and c) to generate its 50%, 75% and 95% percentiles of the bioelectrical variables. Methods Forty-nine elite SS female swimmers of two age categories, comen (Co: 13.9 ± 0.9 years, n = 34) and junior (Jr: 16.3 ± 0.6 years, n = 15), performed a long, high intensity training session. Body mass (BM) and bioelectrical variables (R, resistance; Xc, reactance; PA, phase angle; and Z, impedance module) were assessed pre- and post-training. BIVA was used to characterize 1) the distribution pattern of the bioelectrical vector (BIA vector) for both age groups, and 2) pre- to post-training BIA vector migration. Bioelectrical variables were also correlated with BM change values. Results Most swimmers were mostly located outside the 75% and some beyond the 95% percentile of the bioelectrical tolerance ellipses of the general population. The BIA vector showed statistically significant differences in both Co (T2 = 134.7, p = 0.0001) and Jr (T2 = 126.2, p < 0.001). Both groups were also bioelectrically different (T2 = 17.6, p < 0.001). After the training session, a decrease in BM (p = 0.0001) and an increase in BIA variables (p = 0.01) was observed. BIVA also showed a significant pre-post vector migration both in Co (T2 = 82.1; p < 0.001) and Jr (T2 = 41.8; p < 0.001). No correlations were observed between BM changes and bioelectrical variables. Conclusions BIVA showed specific bioelectrical characteristics in young elite SS athletes. Considering the decrease in BM and the migration of the BIA vector, we conclude that the

  8. High-resolution manometry combined with impedance measurements discriminates the cause of dysphagia in children.

    PubMed

    Rommel, Nathalie; Omari, Taher I; Selleslagh, Margot; Kritas, Stamatiki; Cock, Charles; Rosan, Rachel; Rodriguez, Leonel; Nurko, Samuel

    2015-12-01

    high-resolution manometry and impedance measurements with pressure-flow analysis can differentiate paediatric patients with dysphagia symptoms in relation to either weak peristalsis (poor bolus clearance) or over-pressurization (abnormal bolus flow resistance). HOW MIGHT IT IMPACT ON CLINICAL PRACTICE IN THE FUTURE? • This study supports the use of a novel objective analysis method on recordings that are readily used in paediatric clinical practice. • The pressure-flow approach allows discriminating esophageal dysfunction in relation to dysphagia symptoms in children. This has not been achieved in children with current analysis methods. • The new findings of this study allow a dichotomous categorization of esophageal function, which may help to guide the selection of the most optimal treatment such as pharmacological or endoscopic therapy.

  9. Optimizing electrode configuration for electrical impedance measurements of muscle via the finite element method.

    PubMed

    Jafarpoor, Mina; Li, Jia; White, Jacob K; Rutkove, Seward B

    2013-05-01

    Electrical impedance myography (EIM) is a technique for the evaluation of neuromuscular diseases, including amyotrophic lateral sclerosis and muscular dystrophy. In this study, we evaluated how alterations in the size and conductivity of muscle and thickness of subcutaneous fat impact the EIM data, with the aim of identifying an optimized electrode configuration for EIM measurements. Finite element models were developed for the human upper arm based on anatomic data; material properties of the tissues were obtained from rat and published sources. The developed model matched the frequency-dependent character of the data. Of the three major EIM parameters, resistance, reactance, and phase, the reactance was least susceptible to alterations in the subcutaneous fat thickness, regardless of electrode arrangement. For example, a quadrupling of fat thickness resulted in a 375% increase in resistance at 35 kHz but only a 29% reduction in reactance. By further optimizing the electrode configuration, the change in reactance could be reduced to just 0.25%. For a fixed 30 mm distance between the sense electrodes centered between the excitation electrodes, an 80 mm distance between the excitation electrodes was found to provide the best balance, with a less than 1% change in reactance despite a doubling of subcutaneous fat thickness or halving of muscle size. These analyses describe a basic approach for further electrode configuration optimization for EIM.

  10. Indirect measurement of lung density and air volume from electrical impedance tomography (EIT) data.

    PubMed

    Nebuya, Satoru; Mills, Gary H; Milnes, Peter; Brown, Brian H

    2011-12-01

    This paper describes a method for estimating lung density, air volume and changes in fluid content from a non-invasive measurement of the electrical resistivity of the lungs. Resistivity in Ω m was found by fitting measured electrical impedance tomography (EIT) data to a finite difference model of the thorax. Lung density was determined by comparing the resistivity of the lungs, measured at a relatively high frequency, with values predicted from a published model of lung structure. Lung air volume can then be calculated if total lung weight is also known. Temporal changes in lung fluid content will produce proportional changes in lung density. The method was implemented on EIT data, collected using eight electrodes placed in a single plane around the thorax, from 46 adult male subjects and 36 adult female subjects. Mean lung densities (±SD) of 246 ± 67 and 239 ± 64 kg m(-3), respectively, were obtained. In seven adult male subjects estimates of 1.68 ± 0.30, 3.42 ± 0.49 and 4.40 ± 0.53 l in residual volume, functional residual capacity and vital capacity, respectively, were obtained. Sources of error are discussed. It is concluded that absolute differences in lung density of about 30% and changes over time of less than 30% should be detected using the current technology in normal subjects. These changes would result from approximately 300 ml increase in lung fluid. The method proposed could be used for non-invasive monitoring of total lung air and fluid content in normal subjects but needs to be assessed in patients with lung disease.

  11. Cost-effective broad-band electrical impedance spectroscopy measurement circuit and signal analysis for piezo-materials and ultrasound transducers

    PubMed Central

    Lewis, George K; Lewis, George K; Olbricht, William

    2008-01-01

    This paper explains the circuitry and signal processing to perform electrical impedance spectroscopy on piezoelectric materials and ultrasound transducers. Here, we measure and compare the impedance spectra of 2−5 MHz piezoelectrics, but the methodology applies for 700 kHz–20 MHz ultrasonic devices as well. Using a 12 ns wide 5 volt pulsing circuit as an impulse, we determine the electrical impedance curves experimentally using Ohm's law and fast Fourier transform (FFT), and compare results with mathematical models. The method allows for rapid impedance measurement for a range of frequencies using a narrow input pulse, digital oscilloscope and FFT techniques. The technique compares well to current methodologies such as network and impedance analyzers while providing additional versatility in the electrical impedance measurement. The technique is theoretically simple, easy to implement and completed with ordinary laboratory instrumentation for minimal cost. PMID:19081773

  12. A cell impedance measurement device for the cytotoxicity assay dependent on the velocity of supplied toxic fluid

    NASA Astrophysics Data System (ADS)

    Kang, Yoon-Tae; Kim, Min-Ji; Cho, Young-Ho

    2018-04-01

    We present a cell impedance measurement chip capable of characterizing the toxic response of cells depending on the velocity of the supplied toxic fluid. Previous impedance-based devices using a single open-top chamber have been limited to maintaining a constant supply velocity, and devices with a single closed-top chamber present difficulties in simultaneous cytotoxicity assay for varying levels of supply velocities. The present device, capable of generating constant and multiple levels of toxic fluid velocity simultaneously within a single stepwise microchannel, performs a cytotoxicity assay dependent on toxic fluid velocity, in order to find the effective velocity of toxic fluid to cells for maximizing the cytotoxic effect. We analyze the cellular toxic response of 5% ethanol media supplied to cancer cells within a toxic fluid velocity range of 0-8.3 mm s-1. We observe the velocity-dependent cell detachment rate, impedance, and death rate. We find that the cell detachment rate decreased suddenly to 2.4% at a velocity of 4.4 mm s-1, and that the change rates of cell resistance and cell capacitance showed steep decreases to 8% and 41%, respectively, at a velocity of 5.7 mm s-1. The cell death rate and impedance fell steeply to 32% at a velocity of 5.7 mm s-1. We conclude that: (1) the present device is useful in deciding on the toxic fluid velocity effective to cytotoxicity assay, since the cellular toxic response is dependent on the velocity of toxic fluid, and; (2) the cell impedance analysis facilitates a finer cellular response analysis, showing better correlation with the cell death rate, compared to conventional visual observation. The present device, capable of performing the combinational analysis of toxic fluid velocity and cell impedance, has potential for application to the fine cellular toxicity assay of drugs with proper toxic fluid velocity.

  13. Propagation of sound through the Earth's atmosphere. 1: Measurement of sound absorption in the air. 2: Measurement of ground impedance

    NASA Technical Reports Server (NTRS)

    Becher, J.; Meredith, R. W.; Zuckerwar, A. J.

    1981-01-01

    The fabrication of parts for the acoustic ground impedance meter was completed, and the instrument tested. Acoustic ground impedance meter, automatic data processing system, cooling system for the resonant tube, and final results of sound absorption in N2-H2O gas mixtures at elevated temperatures are described.

  14. Prediction of specific damage or infarction from the measurement of tissue impedance following repetitive brain ischaemia in the rat.

    PubMed

    Klein, H C; Krop-Van Gastel, W; Go, K G; Korf, J

    1993-02-01

    The development of irreversible brain damage during repetitive periods of hypoxia and normoxia was studied in anaesthetized rats with unilateral occlusion of the carotid artery (modified Levine model). Rats were exposed to 10 min hypoxia and normoxia until severe damage developed. As indices of damage, whole striatal tissue impedance (reflecting cellular water uptake), sodium/potassium contents (due to exchange with blood). Evans Blue staining (blood-brain barrier [BBB] integrity) and silver staining (increased in irreversibly damaged neurons) were used. A substantial decrease in blood pressure was observed during the hypoxic periods possibly producing severe ischaemia. Irreversibly increased impedance, massive changes in silver staining, accumulation of whole tissue Na and loss of K occurred only after a minimum of two periods of hypoxia, but there was no disruption of the BBB. Microscopic examination of tissue sections revealed that cell death was selective with reversible impedance changes, but became massive and non-specific after irreversible increase of the impedance. The development of brain infarcts could, however, not be predicted from measurements of physiological parameters in the blood. We suggest that the development of cerebral infarction during repetitive periods of hypoxia may serve as a model for the development of brain damage in a variety of clinical conditions. Furthermore, the present model allows the screening of potential therapeutic measuring of the prevention and treatment of both infarction and selective cell death.

  15. Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children.

    PubMed

    Prachuapthunyachart, Sittichoke; Jarasvaraparn, Chaowapong; Gremse, David A

    2017-01-01

    Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determine whether the Gastroesophageal reflux disease Assessment Symptom Questionnaire composite symptom scores and individual symptom scores correlate with outcomes in esophageal multichannel intraluminal impedance-pH monitoring. A total of 26 patients with gastroesophageal reflux disease-associated symptoms, aged 0-2 years, for whom both esophageal multichannel intraluminal impedance-pH monitoring and Gastroesophageal reflux disease Assessment Symptom Questionnaire survey results were available were included in the study. Gastroesophageal reflux disease Assessment Symptom Questionnaire score data were collected from a 7-day recall of parent's responses about the frequency and severity of gastroesophageal reflux disease symptoms, which determined the individual symptom scores. The composite symptom scores is the sum of all individual symptom scores. Multichannel intraluminal impedance-pH study results were compared to Gastroesophageal reflux disease Assessment Symptom Questionnaire data using Pearson correlation. Among 26 patients, a total number of 2817 (1700 acid and 1117 non-acid) reflux episodes and 845 clinical reflux behaviors were recorded. There were significant correlations between the reflux index and the individual symptom scores for coughing/gagging/choking (r 2 = 0.2842, p = 0.005), the impedance score and individual symptom scores for coughing/gagging/choking (r 2 = 0.2482, p = 0.009), the reflux symptom index for acid reflux-related coughing/gagging/choking and the individual symptom scores for coughing/gagging/choking (r 2 = 0.1900, p = 0.026), the impedance score and

  16. Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children

    PubMed Central

    Prachuapthunyachart, Sittichoke; Jarasvaraparn, Chaowapong; Gremse, David A

    2017-01-01

    Background: Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determine whether the Gastroesophageal reflux disease Assessment Symptom Questionnaire composite symptom scores and individual symptom scores correlate with outcomes in esophageal multichannel intraluminal impedance-pH monitoring. Methods: A total of 26 patients with gastroesophageal reflux disease–associated symptoms, aged 0–2 years, for whom both esophageal multichannel intraluminal impedance-pH monitoring and Gastroesophageal reflux disease Assessment Symptom Questionnaire survey results were available were included in the study. Gastroesophageal reflux disease Assessment Symptom Questionnaire score data were collected from a 7-day recall of parent’s responses about the frequency and severity of gastroesophageal reflux disease symptoms, which determined the individual symptom scores. The composite symptom scores is the sum of all individual symptom scores. Multichannel intraluminal impedance-pH study results were compared to Gastroesophageal reflux disease Assessment Symptom Questionnaire data using Pearson correlation. Results: Among 26 patients, a total number of 2817 (1700 acid and 1117 non-acid) reflux episodes and 845 clinical reflux behaviors were recorded. There were significant correlations between the reflux index and the individual symptom scores for coughing/gagging/choking (r2 = 0.2842, p = 0.005), the impedance score and individual symptom scores for coughing/gagging/choking (r2 = 0.2482, p = 0.009), the reflux symptom index for acid reflux-related coughing/gagging/choking and the individual symptom scores for coughing/gagging/choking (r2 = 0.1900, p = 0

  17. Method, system and computer-readable media for measuring impedance of an energy storage device

    DOEpatents

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.; Motloch, Chester G.

    2016-01-26

    Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. A time profile of this sampled signal has a duration that is a few periods of the lowest frequency. A voltage response of the battery, average deleted, is an impedance of the battery in a time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time profile by rectifying relative to sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

  18. Increased abdominal fat levels measured by bioelectrical impedance are associated with histological lesions of nonalcoholic steatohepatitis.

    PubMed

    Margariti, Aikaterini; Kontogianni, Meropi D; Tileli, Nafsika; Georgoulis, Michael; Deutsch, Melanie; Zafeiropoulou, Rodessa; Tiniakos, Dina; Manios, Yannis; Pectasides, Dimitrios; Papatheodoridis, George V

    2015-08-01

    Abdominal fat is considered to play an important role in nonalcoholic fatty liver disease (NAFLD), although it is not adequately studied because abdominal fat levels cannot be estimated easily. In this study, associations between abdominal obesity, as assessed by abdominal bioelectrical impedance analysis (BIA), and the characteristics of patients with NAFLD were explored. Seventy-four consecutive NAFLD patients who underwent measurement of abdominal fat levels by BIA were included. Levels of abdominal fat 12.5 or less and more than 12.5 were considered to be average and increased, respectively. The mean±SD BMI was 30±4 kg/m and the mean abdominal fat levels were 16±5, whereas 26% of patients had average abdominal fat levels. Patients with average compared with those with increased abdominal fat levels were more frequently women (50 vs. 12%, P=0.001), had lower BMI (27±3 vs. 31±4 kg/m, P<0.001), lower Homeostasis Model Assessment index (2.6±1.4 vs. 3.9±2.7, P=0.045), and lower median liver stiffness on transient elastography (5.3 vs. 6.8 kPa, P=0.025). In patients with available liver biopsy, steatohepatitis was present more frequently in patients with increased compared with average abdominal fat levels (78 vs. 38%, P=0.030) and in patients with BMI 30 or more compared with less than 30 kg/m (87 vs. 48%, P=0.033), but similar in patients with increased or normal waist circumference (67 vs. 56%, P=0.693). Average levels of abdominal fat, as assessed by abdominal BIA, are mainly present in female patients with NAFLD and are associated with a lower degree of insulin resistance. Increased abdominal fat as assessed by BIA and obesity seem to represent strong risk factors for histological steatohepatitis.

  19. FEM/BEM impedance and power analysis for measured LGS SH-SAW devices.

    PubMed

    Kenny, Thomas D; Pollard, Thomas B; Berkenpas, Eric; da Cunha, Mauricio Pereira

    2006-02-01

    Pure shear horizontal piezoelectrically active surface and bulk acoustic waves (SH-SAW and SH-BAW) exist along rotated Y-cuts, Euler angles (0 degrees, theta, 90 degrees), of trigonal class 32 group crystals, which include the LGX family of crystals (langasite, langatate, and langanite). In this paper both SH-SAW and SH-BAW generated by finite-length, interdigital transducers (IDTs) on langasite, Euler angles (0 degrees, 22 degrees, 90 degrees), are simulated using combined finite- and boundary-element methods (FEM/BEM). Aluminum and gold IDT electrodes ranging in thickness from 600 A to 2000 A have been simulated, fabricated, and tested, with both free and metalized surfaces outside the IDT regions considered. Around the device's operating frequency, the percent difference between the calculated IDT impedance magnitude using the FEM/BEM model and the measurements is better than 5% for the different metal layers and thicknesses considered. The proportioning of SH-SAW and SH-BAW power is analyzed as a function of the number of IDT electrodes; type of electrode metal; and relative thickness of the electrode film, h/wavelength, where wavelength is the SH-SAW wavelength. Simulation results show that moderate mechanical loading by gold electrodes increases the proportion of input power converted to SH-SAW. For example, with a split-electrode IDT, comprising 238 electrodes with a relative thickness h/wavelength = 0.63% and surrounded by an infinitesimally thin conducting film, nearly 9% more input power is radiated as SH-SAW when gold instead of aluminum electrodes are used.

  20. Validation of the force and frequency characteristics of the activator adjusting instrument: effectiveness as a mechanical impedance measurement tool.

    PubMed

    Keller, T S; Colloca, C J; Fuhr, A W

    1999-02-01

    To determine the dynamic force-time and force-frequency characteristics of the Activator Adjusting Instrument and to validate its effectiveness as a mechanical impedance measurement device; in addition, to refine or optimize the force-frequency characteristics of the Activator Adjusting Instrument to provide enhanced dynamic structural measurement reliability and accuracy. An idealized test structure consisting of a rectangular steel beam with a static stiffness similar to that of the human thoracolumbar spine was used for validation of a method to determine the dynamic mechanical response of the spine. The Activator Adjusting Instrument equipped with a load cell and accelerometer was used to measure forces and accelerations during mechanical excitation of the steel beam. Driving point and transfer mechanical impedance and resonant frequency of the beam were determined by use of a frequency spectrum analysis for different force settings, stylus masses, and stylus tips. Results were compared with beam theory and transfer impedance measurements obtained by use of a commercial electronic PCB impact hammer. The Activator Adjusting Instrument imparted a very complex dynamic impact comprising an initial high force (116 to 140 N), short duration pulse (<0.1 ms) followed by several lower force (30 to 100 N), longer duration impulses (1 to 5 ms). The force profile was highly reproducible in terms of the peak impulse forces delivered to the beam structure (<8% variance). Spectrum analysis of the Activator Adjusting Instrument impulse indicated that the Activator Adjusting Instrument has a variable force spectrum and delivers its peak energy at a frequency of 20 Hz. Added masses and different durometer stylus tips had very little influence on the Activator Adjusting Instrument force spectrum. The resonant frequency of the beam was accurately predicted by both the Activator Adjusting Instrument and electronic PCB impact hammer, but variations in the magnitude of the driving

  1. Mechanical impedance and acoustic mobility measurement techniques of specifying vibration environments

    NASA Technical Reports Server (NTRS)

    Kao, G. C.

    1973-01-01

    Method has been developed for predicting interaction between components and corresponding support structures subjected to acoustic excitations. Force environments determined in spectral form are called force spectra. Force-spectra equation is determined based on one-dimensional structural impedance model.

  2. Pulmonary Vascular Input Impedance is a Combined Measure of Pulmonary Vascular Resistance and Stiffness and Predicts Clinical Outcomes Better than PVR Alone in Pediatric Patients with Pulmonary Hypertension

    PubMed Central

    Hunter, Kendall S.; Lee, Po-Feng; Lanning, Craig J.; Ivy, D. Dunbar; Kirby, K. Scott; Claussen, Lori R.; Chan, K. Chen; Shandas, Robin

    2011-01-01

    Background Pulmonary vascular resistance (PVR) is the current standard for evaluating reactivity in children with pulmonary arterial hypertension (PAH). However, PVR measures only the mean component of right ventricular afterload and neglects pulsatile effects. We recently developed and validated an method to measure pulmonary vascular input impedance, which revealed excellent correlation between the zero-harmonic impedance value and PVR, and suggested a correlation between higher harmonic impedance values and pulmonary vascular stiffness (PVS). Here we show that input impedance can be measured routinely and easily in the catheterization laboratory, that impedance provides PVR and PVS from a single measurement, and that impedance is a better predictor of disease outcomes compared to PVR. Methods Pressure and velocity waveforms within the main PA were measured during right-heart catheterization of patients with normal PA hemodynamics (n=14) and those with PAH undergoing reactivity evaluation (49 subjects; 95 conditions). A correction factor needed to transform velocity into flow was obtained by calibrating against cardiac output. Input impedance was obtained off-line by dividing Fourier-transformed pressure and flow waveforms. Results Exceptional correlation was found between the indexed zero harmonic of impedance and indexed PVR (y=1.095·x+1.381, R2=0.9620). Additionally, the modulus sum of the first two harmonics of impedance was found to best correlate with indexed pulse pressure over stroke volume (PP/SV) (y=13.39·x-0.8058, R2=0.7962). Amongst a subset of PAH patients (n=25), cumulative logistic regression between outcomes to total indexed impedance was better (RL2=0.4012) than between outcomes and indexed PVR (RL2=0.3131). Conclusions Input impedance can be consistently and easily obtained from PW Doppler and a single catheter pressure measurement, provides comprehensive characterization of the main components of RV afterload, and better predicts patient

  3. Locating interfaces in vertically-layered materials and determining concentrations in mixed materials utilizing acoustic impedance measurements

    DOEpatents

    Langlois, G.N.

    1983-09-13

    Measurement of the relative and actual value of acoustic characteristic impedances of an unknown substance, location of the interfaces of vertically-layered materials, and the determination of the concentration of a first material mixed in a second material are disclosed. A highly damped ultrasonic pulse is transmitted into one side of a reference plate, such as a tank wall, where the other side of the reference plate is in physical contact with the medium to be measured. The amplitude of a return signal, which is the reflection of the transmitted pulse from the interface between the other side of the reference plate and the medium, is measured. The amplitude value indicates the acoustic characteristic impedance of the substance relative to that of the reference plate or relative to that of other tested materials. Discontinuities in amplitude with repeated measurements for various heights indicate the location of interfaces in vertically-layered materials. Standardization techniques permit the relative acoustic characteristic impedance of a substance to be converted to an actual value. Calibration techniques for mixtures permit the amplitude to be converted to the concentration of a first material mixed in a second material. 6 figs.

  4. Locating interfaces in vertically-layered materials and determining concentrations in mixed materials utilizing acoustic impedance measurements

    DOEpatents

    Langlois, Gary N.

    1983-09-13

    Measurement of the relative and actual value of acoustic characteristic impedances of an unknown substance, location of the interfaces of vertically-layered materials, and the determination of the concentration of a first material mixed in a second material. A highly damped ultrasonic pulse is transmitted into one side of a reference plate, such as a tank wall, where the other side of the reference plate is in physical contact with the medium to be measured. The amplitude of a return signal, which is the reflection of the transmitted pulse from the interface between the other side of the reference plate and the medium, is measured. The amplitude value indicates the acoustic characteristic impedance of the substance relative to that of the reference plate or relative to that of other tested materials. Discontinuities in amplitude with repeated measurements for various heights indicate the location of interfaces in vertically-layered materials. Standardization techniques permit the relative acoustic characteristic impedance of a substance to be converted to an actual value. Calibration techniques for mixtures permit the amplitude to be converted to the concentration of a first material mixed in a second material.

  5. Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry.

    PubMed

    Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C

    2016-06-01

    Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs. Copyright © 2016. Published by Elsevier Ltd.

  6. Novel circuit design for high-impedance and non-local electrical measurements of two-dimensional materials

    NASA Astrophysics Data System (ADS)

    De Sanctis, Adolfo; Mehew, Jake D.; Alkhalifa, Saad; Tate, Callum P.; White, Ashley; Woodgate, Adam R.; Craciun, Monica F.; Russo, Saverio

    2018-02-01

    Two-dimensional materials offer a novel platform for the development of future quantum technologies. However, the electrical characterisation of topological insulating states, non-local resistance, and bandgap tuning in atomically thin materials can be strongly affected by spurious signals arising from the measuring electronics. Common-mode voltages, dielectric leakage in the coaxial cables, and the limited input impedance of alternate-current amplifiers can mask the true nature of such high-impedance states. Here, we present an optical isolator circuit which grants access to such states by electrically decoupling the current-injection from the voltage-sensing circuitry. We benchmark our apparatus against two state-of-the-art measurements: the non-local resistance of a graphene Hall bar and the transfer characteristic of a WS2 field-effect transistor. Our system allows the quick characterisation of novel insulating states in two-dimensional materials with potential applications in future quantum technologies.

  7. Red blood cells aggregability measurement of coagulating blood in extracorporeal circulation system with multiple-frequency electrical impedance spectroscopy.

    PubMed

    Li, Jianping; Sapkota, Achyut; Kikuchi, Daisuke; Sakota, Daisuke; Maruyama, Osamu; Takei, Masahiro

    2018-07-30

    Red blood cells (RBCs) aggregability A G of coagulating blood in extracorporeal circulation system has been investigated under the condition of pulsatile flow. Relaxation frequency f c from the multiple-frequency electrical impedance spectroscopy is utilized to obtain RBCs aggregability A G . Compared with other methods, the proposed multiple-frequency electrical impedance method is much easier to obtain non-invasive measurement with high speed and good penetrability performance in biology tissues. Experimental results show that, RBCs aggregability A G in coagulating blood falls down with the thrombus formation while that in non-coagulation blood almost keeps the same value, which has a great agreement with the activated clotting time (ACT) fibrinogen concertation (F bg ) tests. Modified Hanai formula is proposed to quantitatively analyze the influence of RBCs aggregation on multiple-frequency electrical impedance measurement. The reduction of RBCs aggregability A G is associated with blood coagulation reaction, which indicates the feasibility of the high speed, compact and cheap on-line thrombus measurement biosensors in extracorporeal circulation systems. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. AC-impedance measurements during thermal runaway process in several lithium/polymer batteries

    NASA Astrophysics Data System (ADS)

    Uchida, I.; Ishikawa, H.; Mohamedi, M.; Umeda, M.

    In this work, we present a set of thermal characterization experiments of charged prismatic polymer lithium-ion battery (PLB) comparatively with those of a lithium-ion battery (LIB). These cells at different state of charge (SOC) were tested inside an accelerated rate calorimeter (ARC) to determine the onset-of-thermal runaway (OTR) temperatures. In addition, the thermally activated components of these cells were followed by monitoring the impedance (at 1 kHz) and the open-circuit voltage (OCV) as a function of temperature. An increase in the impedance was observed at around 133 °C corresponding to the polyethylene separator shutdown. Above 140 °C, the OCV dropped to zero indicating an internal short-circuit due the separator meltdown suggesting that the pinholes created in the separator at meltdown are large enough to create an internal short-circuit.

  9. Offline Impedance Measurements for Detection and Mitigation of Dangerous Implant Interactions: An RF Safety Prescreen

    PubMed Central

    Ellenor, Christopher W; Stang, Pascal P; Etezadi-Amoli, Maryam; Pauly, John M; Scott, Greig C

    2015-01-01

    Purpose The concept of a “radiofrequency safety prescreen” is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. Theory The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. Methods A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. Results Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. Conclusions The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire. Magn Reson Med 73:1328–1339, 2015. © 2014 Wiley Periodicals, Inc. PMID:24623586

  10. Electrical impedance measurements in the arm and the leg during a thirty day bed rest study

    NASA Technical Reports Server (NTRS)

    Cardus, David; Jaweed, Mazher; McTaggart, Wesley

    1995-01-01

    The need to detect, follow, and understand the effects of gravity on body fluid distribution is a constant stimulus to the quest for new techniques in this area of research. One of these techniques is electrical bioimpedance spectroscopy (BIS). Although not new, this is a technique whose applications to biomedical research are fairly recent. What is new is the development of instrumentation that has made practical the use of impedance spectroscopy in the biomedical setting, particularly in studies involving human subjects. The purpose of this paper is to report impedance spectroscopy observations made on a subject who was submitted to bed rest for a period of thirty days. These observations were made as part of a study on muscle atrophy during a thirty day head down bed rest. Since bed rest studies are very costly in human and financial terms, and technically difficult to realize, we felt that even though the present study deals only with a single case it was worthy of reporting because it illustrates kinds of questions impedance spectroscopy may help to answer in microgravity research.

  11. Offline impedance measurements for detection and mitigation of dangerous implant interactions: an RF safety prescreen.

    PubMed

    Ellenor, Christopher W; Stang, Pascal P; Etezadi-Amoli, Maryam; Pauly, John M; Scott, Greig C

    2015-03-01

    The concept of a "radiofrequency safety prescreen" is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire. © 2014 Wiley Periodicals, Inc.

  12. Smartphone-based portable biosensing system using impedance measurement with printed electrodes for 2,4,6-trinitrotoluene (TNT) detection.

    PubMed

    Zhang, Diming; Jiang, Jing; Chen, Junye; Zhang, Qian; Lu, Yanli; Yao, Yao; Li, Shuang; Logan Liu, Gang; Liu, Qingjun

    2015-08-15

    Rapid, sensitive, selective and portable detection of 2,4,6-trinitrotoluene (TNT) is in high demand for public safety and environmental monitoring. In this study, we reported a smartphone-based system using impedance monitoring for TNT detection. The screen-printed electrodes modified with TNT-specific peptides were used as disposable a biosensor to produce impedance responses to TNT. The responses could be monitored by a hand-held device and send out to smartphone through Bluetooth. Then, the smartphone was used to display TNT responses in real time and report concentration finally. In the measurement, the system was demonstrated to detect TNT at concentration as low as 10(-6) M and distinguish TNT versus different chemicals in high specificity. Thus, the smartphone-based biosensing platform provided a convenient and efficient approach to design portable instruments for chemical detections such as TNT recognition. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. A 0.18 μm CMOS LDO Regulator for an On-Chip Sensor Array Impedance Measurement System.

    PubMed

    Pérez-Bailón, Jorge; Márquez, Alejandro; Calvo, Belén; Medrano, Nicolás

    2018-05-02

    This paper presents a fully integrated 0.18 μm CMOS Low-Dropout (LDO) Voltage Regulator specifically designed to meet the stringent requirements of a battery-operated impedance spectrometry multichannel CMOS micro-instrument. The proposed LDO provides a regulated 1.8 V voltage from a 3.6 V to 1.94 V battery voltage over a −40 °C to 100 °C temperature range, with a compact topology (<0.10 mm² area) and a constant quiescent current of only 7.45 μA with 99.985% current efficiency, achieving remarkable state-of-art Figures of Merit (FoMs) for the regulating⁻transient performance. Experimental measurements validate its suitability for the target application, paving the way towards the future achievement of a truly portable System on Chip (SoC) platform for impedance sensors.

  14. The Performance of Dammar-based Paint System Evaluated by Electrochemical Impedance Spectroscopy (EIS) and Potential Time Measurement (PTM)

    NASA Astrophysics Data System (ADS)

    Omar, N. M.; Ahmad, A. Hanom

    2009-06-01

    The coating resistance of the Dammar-based paint system was determined by using Electrochemical Impedance Spectroscopy (EIS), whereas, the corrosion potential analysis was determined by using potential time measurement (PTM) method. Carotenoid pigment obtained from Capsicum Annum (dried chili pepper) was added into the mixture of dammar and acrylic polyol resin and the paint systems were proofed on Aluminium steel Q-panels as a substrate. Result shows that the paint system with a composition of 35% dammar (CD35%) possessed the higher corrosion resistance after 30 days of exposure in 3% NaCl solution for electrochemical impedance spectroscopy and also can withstand the longest time for delimitation protection in PTM analysis. The results prove that the developed organic paint system can improve the electrochemical and corrosion protection properties of a paint system.

  15. Locating damage using integrated global-local approach with wireless sensing system and single-chip impedance measurement device.

    PubMed

    Lin, Tzu-Hsuan; Lu, Yung-Chi; Hung, Shih-Lin

    2014-01-01

    This study developed an integrated global-local approach for locating damage on building structures. A damage detection approach with a novel embedded frequency response function damage index (NEFDI) was proposed and embedded in the Imote2.NET-based wireless structural health monitoring (SHM) system to locate global damage. Local damage is then identified using an electromechanical impedance- (EMI-) based damage detection method. The electromechanical impedance was measured using a single-chip impedance measurement device which has the advantages of small size, low cost, and portability. The feasibility of the proposed damage detection scheme was studied with reference to a numerical example of a six-storey shear plane frame structure and a small-scale experimental steel frame. Numerical and experimental analysis using the integrated global-local SHM approach reveals that, after NEFDI indicates the approximate location of a damaged area, the EMI-based damage detection approach can then identify the detailed damage location in the structure of the building.

  16. The application of impedance measurement to assess biofilm development on technical materials used for water supply system construction

    NASA Astrophysics Data System (ADS)

    Wolf, Mirela; Traczewska, Teodora; Grzebyk, Tomasz

    2017-11-01

    The lack of biological stability of water which is introduced into the network, leads primarily to its secondary contamination during transport to the consumer. The water that is biologically unstable creates ideal conditions for colonization of the inner surface of pipelines by microorganisms and adhesion of their products (biocorrosion). The studies was conducted using the identified microorganisms isolated from the water supply network which accounted inocula in continuous culture of biofilm in CDC reactor. As a result of studies it was revealed the presence of biofilm formed on different materials polyethylene, polypropylene, polyvinyl chloride, polybutylene. Microbiological biodiversity of organisms inhabiting a biofilm of the diversity of nucleic acids was used. It was observed the amount of the psychrophilic bacteria oscillation in the effluent from the reactor. It was also determined the affinity of various bacteria to the plastic through adhesion measurement using impedance spectroscopy. For impedance measurements apparatus SIGNAL RECOVERY 7280 DSP LOCK-IN AMPLIFIER was used, recording impedance components (real and imaginary). The results will allow for the creation of biosensor systems that can be used in predicting health risks in connection with drinking water and taking corrective actions.

  17. Impedance-estimation methods, modeling methods, articles of manufacture, impedance-modeling devices, and estimated-impedance monitoring systems

    DOEpatents

    Richardson, John G [Idaho Falls, ID

    2009-11-17

    An impedance estimation method includes measuring three or more impedances of an object having a periphery using three or more probes coupled to the periphery. The three or more impedance measurements are made at a first frequency. Three or more additional impedance measurements of the object are made using the three or more probes. The three or more additional impedance measurements are made at a second frequency different from the first frequency. An impedance of the object at a point within the periphery is estimated based on the impedance measurements and the additional impedance measurements.

  18. Impact of exacerbations on respiratory system impedance measured by a forced oscillation technique in COPD: a prospective observational study.

    PubMed

    Kamada, Takahiro; Kaneko, Masahiro; Tomioka, Hiromi

    2017-01-01

    Forced oscillation technique (FOT) has been reported to be useful in the evaluation and management of obstructive lung disease, including COPD. To date, no data are available concerning long-term changes in respiratory system impedance measured by FOT. Additionally, although exacerbations have been reported to be associated with excessive lung function decline in COPD, the impact of exacerbations on the results of FOT has not been demonstrated. The aim of this study was to investigate the longitudinal changes in respiratory system impedance and the influence of exacerbations thereon. Between March 2011 and March 2012, outpatients who attended Kobe City Medical Center West Hospital with a diagnosis of COPD were assessed for eligibility. Baseline patient characteristics (age, sex, body mass index, smoking history, current smoking status, COPD stage), lung function (post-bronchodilator forced expiratory volume in 1 second [FEV 1 ]), blood tests (neutrophils and eosinophils), FOT, and COPD assessment test results were collected at enrollment. Lung function and FOT were examined every 6 months until March 2016. Annual changes in FEV 1 and FOT parameters were obtained from the slope of the linear regression curve. The patients were divided into 2 groups based on exacerbation history. Fifty-one of 58 patients with COPD were enrolled in this study. The median follow-up period was 57 (52-59) months. Twenty-five (49%) patients experienced exacerbations. A significant annual decline in FEV 1 and respiratory system impedance were shown. Additionally, annual changes in FEV 1 , respiratory system resistance at 5 Hz, respiratory system reactance at 5 Hz, and resonant frequency were greater in patients with exacerbations than in those without exacerbations. Exacerbations of COPD lead not only to a decline in lung function but also to an increase in respiratory system impedance.

  19. Design And Construction of an Impedance Tube for Measuring Sound Absorptivity and Transmissibility of Materials Using Transfer Function Method

    NASA Astrophysics Data System (ADS)

    Gowda, Haarish Kapaninaikappa

    Noise is defined as unwanted sound, when perceived in excess can cause many harmful effects such as annoyance, interference with speech, and hearing loss, hence there is a need to control noise in practical situations. Noise can be controlled actively and/or passively, here we discuss the passive noise control techniques. Passive noise control involves using energy dissipating or reflecting materials such as absorbers or barriers respectively. Damping and isolating materials are also used in eliminating structure-borne noise. These materials exhibit properties such as reflection, absorption and transmission loss when incidence is by a sound source. Thus, there is a need to characterize the acoustical properties of these materials for practical use. The theoretical background of the random incident sound absorption with reverberation room and normal incident sound absorption using impedance tube are well documented. The Transfer Matrix method for measuring transmission loss and absorption coefficient using impedance tube is very attractive since it is rather inexpensive and fast. In this research, a low-cost Impedance Tube is constructed using transfer function method to measure both absorption and transmissibility of materials. Equipment and measurement instruments available in the laboratory were used in the construction of the tube, adhering to cost-effectiveness. Care has been taken for precise construction of tube to ensure better measurement results. Further various samples varying from hard non-porous to soft porous materials were tested for absorption and sound transmission loss. Absorption values were also compared with reverberation room method with the available samples further ensuring the reliability of the newly constructed tube for future measurements.

  20. Impedance spectroscopy of PZT ceramics--measuring diffusion coefficients, mixed conduction, and Pb loss.

    PubMed

    Donnelly, Niall J; Randall, Clive A

    2012-09-01

    Sintering of lead zirconate titanate (PZT) at high temperatures results in loss of Pb unless an ambient Pb activity is maintained. The tell-tale sign of Pb loss is an increased conductivity, usually manifested in unacceptably high values of tanδ. The conductivity is caused by oxygen vacancies and/or electron holes which are a byproduct of Pb evaporation. In the first part of this paper, it is shown how impedance spectroscopy can be used to separate ionic and electronic conductivity in a properly designed sample by selection of appropriate boundary conditions. Subsequently, impedance is used to probe defect concentrations in PZT during prolonged annealing at 700°C. It is found that oxygen vacancies are generated during annealing in air but the rate of generation actually decreases upon lowering the ambient pO(2). These results are explained by a model of Pb evaporation which, in this case, leads predominantly to oxygen vacancy generation. In principle, this effect could be used to generate a specific vacancy concentration in similar Pb-based oxides.

  1. Percentiles of body fat measured by bioelectrical impedance in children and adolescents from Bogotá (Colombia): the FUPRECOL study.

    PubMed

    Escobar-Cardozo, Germán D; Correa-Bautista, Jorge E; González-Jiménez, Emilio; Schmidt-RioValle, Jacqueline; Ramírez-Vélez, Robinson

    2016-04-01

    The analysis of body composition is a fundamental part of nutritional status assessment. The objective of this study was to establish body fat percentiles by bioelectrical impedance in children and adolescents from Bogotá (Colombia) who were part of the FUPRECOL study (Asociación de la Fuerza Prensil con Manifestaciones Tempranas de Riesgo Cardiovascular en Niños y Adolescentes Colombianos - Association between prehensile force and early signs of cardiovascular risk in Colombian children and adolescents). This was a cross-sectional study conducted among 5850 students aged 9-17.9 years old from Bogotá (Colombia). Body fat percentage was measured using foot-to-foot bioelectrical impedance (Tanita®, BF-689), by age and gender. Weight, height, waist circumference, and hip circumference were measured, and sexual maturity was self-staged. Percentiles (P3, P10, P25, P50, P75, P90 and P97) and centile curves were estimated using the LMS method (L [BoxCox curve], M [median curve] and S [variation coefficient curve]), by age and gender. Subjects included were 2526 children and 3324 adolescents. Body fat percentages and centile curves by age and gender were established. For most age groups, values resulted higher among girls than boys. Participants with values above P90 were considered to have a high cardiovascular risk due to excess fat (boys > 23.428.3, girls > 31.0-34.1). Body fat percentage percentiles measured using bioelectrical impedance by age and gender are presented here and may be used as reference to assess nutritional status and to predict cardiovascular risk due to excess fat at an early age. Sociedad Argentina de Pediatría.

  2. Can Total Body Resistance Measured Using Bioelectrical Impedance Analysis Be the Index of Dehydration in Older Japanese Patients?

    PubMed

    Shimizu, Miyuki; Kinoshita, Kensuke; Maeno, Takami; Kobayashi, Hiroyuki; Maeno, Tetsuhiro

    2017-11-01

    Dehydration in older patients has long been considered a significant health problem because it implies increased morbidity and mortality. However, dehydration is detected by a combination of physical signs and blood tests. For older people dwelling at home and in nursing homes, a simple and non-invasive method for detecting dehydration by caregivers is needed. The total body resistance is measured using bioelectrical impedance analysis and is known as an indicator of dehydration. There are no data from older Japanese patients on this issue. We performed this study to examine the relationship between dehydration and total body resistance in Japan. We performed blood tests and measured bioelectrical impedance in older outpatients aged ≥ 65 years from the Internal Medicine Department at Mito Kyodo General Hospital. Patients were classified as dehydrated and non-dehydrated using the dehydration index with a blood urea nitrogen/creatinine ratio > 20, and the mean total body resistance was compared between the two groups. Eighty-one patients were recruited in the study. In the dehydrated group, the mean total body resistance was 439 Ω at 50 kHz, which was significantly higher than that in the non-dehydrated group (408 Ω, P = 0.038). The total body resistance measurements can be used for simple assessment of dehydration among older Japanese patients.

  3. Resonance-mode electrochemical impedance measurements of silicon dioxide supported lipid bilayer formation and ion channel mediated charge transport.

    PubMed

    Lundgren, Anders; Hedlund, Julia; Andersson, Olof; Brändén, Magnus; Kunze, Angelika; Elwing, Hans; Höök, Fredrik

    2011-10-15

    A single-chip electrochemical method based on impedance measurements in resonance mode has been employed to study lipid monolayer and bilayer formation on hydrophobic alkanethiolate and SiO(2) substrates, respectively. The processes were monitored by temporally resolving changes in interfacial capacitance and resistance, revealing information about the rate of formation, coverage, and defect density (quality) of the layers at saturation. The resonance-based impedance measurements were shown to reveal significant differences in the layer formation process of bilayers made from (i) positively charged lipid 1-palmitoyl-2-oleoyl-sn-glycero-3-ethylphosphocholine (POEPC), (ii) neutral lipid 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) on SiO(2), and (iii) monolayers made from POEPC on hydrophobic alkanethiolate substrates. The observed responses were represented with an equivalent circuit, suggesting that the differences primarily originate from the presence of a conductive aqueous layer between the lipid bilayers and the SiO(2). In addition, by adding the ion channel gramicidin D to bilayers supported on SiO(2), channel-mediated charge transport could be measured with high sensitivity (resolution around 1 pA). © 2011 American Chemical Society

  4. Overview Of Impedance Sensors

    NASA Astrophysics Data System (ADS)

    Abele, John E.

    1989-08-01

    Electrical impedance has been one of the many "tools of great promise" that physicians have employed in their quest to measure and/or monitor body function or physiologic events. So far, the expectations for its success have always exceeded its performance. In simplistic terms, physiologic impedance is a measure of the resistance in the volume between electrodes which changes as a function of changes in that volume, the relative impedance of that volume, or a combination of these two. The history and principles of electrical impedance are very nicely reviewed by Geddes and Baker in their textbook "Principles of Applied Biomedical Instrumentation". It is humbling, however, to note that Cremer recorded variations in electrical impedance in frog hearts as early as 1907. The list of potential applications includes the measurement of thyroid function, estrogen activity, galvanic skin reflex, respiration, blood flow by conductivity dilution, nervous activity and eye movement. Commercial devices employing impedance have been and are being used to measure respiration (pneumographs and apneamonitors), pulse volume (impedance phlebographs) and even noninvasive cardiac output.

  5. Microfabricated AC impedance sensor

    DOEpatents

    Krulevitch, Peter; Ackler, Harold D.; Becker, Frederick; Boser, Bernhard E.; Eldredge, Adam B.; Fuller, Christopher K.; Gascoyne, Peter R. C.; Hamilton, Julie K.; Swierkowski, Stefan P.; Wang, Xiao-Bo

    2002-01-01

    A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

  6. Evaluation of electrical broad bandwidth impedance spectroscopy as a tool for body composition measurement in cows in comparison with body measurements and the deuterium oxide dilution method.

    PubMed

    Schäff, C T; Pliquett, U; Tuchscherer, A; Pfuhl, R; Görs, S; Metges, C C; Hammon, H M; Kröger-Koch, C

    2017-05-01

    Body fatness and degree of body fat mobilization in cows vary enormously during their reproduction cycle and influence energy partitioning and metabolic adaptation. The objective of the study was to test bioelectrical impedance spectroscopy (BIS) as a method for predicting fat depot mass (FDM), in living cows. The FDM is defined as the sum of subcutaneous, omental, mesenteric, retroperitoneal, and carcass fat mass. Bioelectrical impedance spectroscopy is compared with the prediction of FDM from the deuterium oxide (DO) dilution method and from body conformation measurements. Charolais × Holstein Friesian (HF; = 18; 30 d in milk) crossbred cows and 2 HF (lactating and nonlactating) cows were assessed by body conformation measurements, BIS, and the DO dilution method. The BCS of cows was a mean of 3.68 (SE 0.64). For the DO dilution method, a bolus of 0.23 g/kg BW DO (60 atom%) was intravenously injected and deuterium (D) enrichment was analyzed in plasma and whey by stabile isotope mass spectrometry, and total body water content was calculated. Impedance measurement was performed using a 4-electrode interface and time domain-based measurement system consisting of a voltage/current converter for applying current stimulus and an amplifier for monitoring voltage across the sensor electrodes. For the BIS, we used complex impedances over three frequency decades that delivers information on intra- and extracellular water and capacity of cell membranes. Impedance data (resistance of extra- and intracellular space, cell membrane capacity, and phase angle) were extracted 1) by simple curve fit to extract the resistance at direct current and high frequency and 2) by using an electrical equivalent circuit. Cows were slaughtered 7 d after BIS and D enrichment measurements and dissected for the measurement of FDM. Multiple linear regression analyses were performed to predict FDM based on data obtained from body conformation measurements, BIS, and D enrichment, and applied

  7. Measurement of changes in impedance of DNA nanowires due to radiation induced structural damage. A novel approach for a DNA-based radiosensitive device

    NASA Astrophysics Data System (ADS)

    Heimbach, Florian; Arndt, Alexander; Nettelbeck, Heidi; Langner, Frank; Giesen, Ulrich; Rabus, Hans; Sellner, Stefan; Toppari, Jussi; Shen, Boxuan; Baek, Woon Yong

    2017-08-01

    The ability of DNA to conduct electric current has been the topic of numerous investigations over the past few decades. Those investigations indicate that this ability is dependent on the molecular structure of the DNA. Radiation-induced damages, which lead to an alteration of the molecular structure, should therefore change the electrical impedance of a DNA molecule. In this paper, the damage due to ionising radiation is shown to have a direct effect on the electrical transport properties of DNA. Impedance measurements of DNA samples were carried out by an AC impedance spectrometer before, during and after irradiation. The samples comprised of DNA segments, which were immobilized between gold electrodes with a gap of 12 μm. The impedance of all DNA samples exhibited rising capacitive behaviour with increasing absorbed dose.

  8. Foot-to-foot bioelectrical impedance analysis: a valuable tool for the measurement of body composition in children.

    PubMed

    Tyrrell, V J; Richards, G; Hofman, P; Gillies, G F; Robinson, E; Cutfield, W S

    2001-02-01

    To determine the accuracy of foot-to-foot bioelectrical impedance analysis (BIA) and anthropometric indices as measures of body composition in children. Comparison of foot-to-foot BIA and anthropometry to dual-energy X-ray absorptiometry (DEXA)-derived body composition in a multi-ethnic group of children. : Eighty-two European, NZ Maori and Pacific Island children aged 4.9-10.9 y. DEXA body composition, foot-to-foot bioelectrical impedance, height, weight, hip and waist measurements. Using a BIA prediction equation derived from our study population we found a high correlation between DEXA and BIA in the estimation of fat-free mass (FFM), fat mass (FM) and percentage body fat (PBF) (r=0.98, 0.98 and 0.94, respectively). BIA-FFM underestimated DEXA-FFM by a mean of 0.75 kg, BIA-FM overestimated DEXA-FM by a mean of 1.02 kg and BIA-PBF overestimated DEXA-PBF by a mean of 2.53%. The correlation between six anthropometric indices (body mass index (BMI), ponderal index, Chinn's weight-for-height index, BMI standard deviation score, weight-for-length index and Cole's weight-for-height index) and DEXA were also examined. The correlation of these indices with PBF was remarkably similar (r=0.85-0.87), more variable with FM (r=0.77-0.94) and poor with FFM (r=0.41-0.75). BIA correlated better than anthropometric indices in the estimation of FFM, FM and PBF. Foot-to-foot BIA is an accurate technique in the measurement of body composition.

  9. Measuring the shock impedance mismatch between high-density carbon and deuterium at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Millot, M.; Celliers, P. M.; Sterne, P. A.; Benedict, L. X.; Correa, A. A.; Hamel, S.; Ali, S. J.; Baker, K. L.; Berzak Hopkins, L. F.; Biener, J.; Collins, G. W.; Coppari, F.; Divol, L.; Fernandez-Panella, A.; Fratanduono, D. E.; Haan, S. W.; Le Pape, S.; Meezan, N. B.; Moore, A. S.; Moody, J. D.; Ralph, J. E.; Ross, J. S.; Rygg, J. R.; Thomas, C.; Turnbull, D. P.; Wild, C.; Eggert, J. H.

    2018-04-01

    Fine-grained diamond, or high-density carbon (HDC), is being used as an ablator for inertial confinement fusion (ICF) research at the National Ignition Facility (NIF). Accurate equation of state (EOS) knowledge over a wide range of phase space is critical in the design and analysis of integrated ICF experiments. Here, we report shock and release measurements of the shock impedance mismatch between HDC and liquid deuterium conducted during shock-timing experiments having a first shock in the ablator ranging between 8 and 14 Mbar. Using ultrafast Doppler imaging velocimetry to track the leading shock front, we characterize the shock velocity discontinuity upon the arrival of the shock at the HDC/liquid deuterium interface. Comparing the experimental data with tabular EOS models used to simulate integrated ICF experiments indicates the need for an improved multiphase EOS model for HDC in order to achieve a significant increase in neutron yield in indirect-driven ICF implosions with HDC ablators.

  10. Impedance measurement of non-locally reactive samples and the influence of the assumption of local reaction.

    PubMed

    Brandão, Eric; Mareze, Paulo; Lenzi, Arcanjo; da Silva, Andrey R

    2013-05-01

    In this paper, the measurement of the absorption coefficient of non-locally reactive sample layers of thickness d1 backed by a rigid wall is investigated. The investigation is carried out with the aid of real and theoretical experiments, which assume a monopole sound source radiating sound above an infinite non-locally reactive layer. A literature search revealed that the number of papers devoted to this matter is rather limited in comparison to those which address the measurement of locally reactive samples. Furthermore, the majority of papers published describe the use of two or more microphones whereas this paper focuses on the measurement with the pressure-particle velocity sensor (PU technique). For these reasons, the assumption that the sample is locally reactive is initially explored, so that the associated measurement errors can be quantified. Measurements in the impedance tube and in a semi-anechoic room are presented to validate the theoretical experiment. For samples with a high non-local reaction behavior, for which the measurement errors tend to be high, two different algorithms are proposed in order to minimize the associated errors.

  11. Verification of three-microphone impedance tube method for measurement of transmission loss in aerogels

    NASA Astrophysics Data System (ADS)

    Connick, Robert J.

    Accurate measurement of normal incident transmission loss is essential for the acoustic characterization of building materials. In this research, a method of measuring normal incidence sound transmission loss proposed by Salissou et al. as a complement to standard E2611-09 of the American Society for Testing and Materials [Standard Test Method for Measurement of Normal Incidence Sound Transmission of Acoustical Materials Based on the Transfer Matrix Method (American Society for Testing and Materials, New York, 2009)] is verified. Two sam- ples from the original literature are used to verify the method as well as a Filtros RTM sample. Following the verification, several nano-material Aerogel samples are measured.

  12. The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers

    PubMed Central

    Omari, Taher I.; Savilampi, Johanna; Kokkinn, Karmen; Schar, Mistyka; Lamvik, Kristin; Doeltgen, Sebastian; Cock, Charles

    2016-01-01

    Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing. Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showed substantial to excellent agreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged from slight to excellent depending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showed excellent test-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showed moderate to substantial test-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged from slight to substantial (mean Interrater ICC 0.15–0.61). Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility. PMID:27190520

  13. Inter- and intraobserver agreement in 24-hour combined multiple intraluminal impedance and pH measurement in children.

    PubMed

    Pilic, Denisa; Höfs, Carolin; Weitmann, Sandra; Nöh, Frank; Fröhlich, Thorsten; Skopnik, Heino; Köhler, Henrik; Wenzl, Tobias G; Schmidt-Choudhury, Anjona

    2011-09-01

    Assessment of intra- and interobserver agreement in multiple intraluminal impedance (MII) measurement between investigators from different institutions. Twenty-four 18- to 24-hour MII tracings were randomly chosen from 4 different institutions (6 per center). Software-aided automatic analysis was performed. Each result was validated by 2 independent investigators from the 4 different centers (4 investigator combinations). For intraobserver agreement, 6 measurements were analyzed twice by the same investigator. Agreement between investigators was calculated using the Cohen kappa coefficient. Interobserver agreement: 13 measurements showed a perfect agreement (kappa > 0.8); 9 had a substantial (kappa 0.61-0.8), 1 a moderate (kappa coefficient 0.41 to 0.6), and 1 a fair agreement (kappa coefficient 0.11-0.4). Median kappa value was 0.83. Intraobserver agreement: 5 tracings showed perfect and 1 showed a substantial agreement. The median kappa value was 0.88. Most measurements showed substantial to perfect intra- and interobserver agreement. Still, we found a few outliers presumably caused by poorer signal quality in some tracings rather than being observer dependent. An improvement of analysis results may be achieved by using a standard analysis protocol, a standardized method for judging tracing quality, better training options for method users, and more interaction between investigators from different institutions.

  14. A Multi-Functional Microelectrode Array Featuring 59760 Electrodes, 2048 Electrophysiology Channels, Stimulation, Impedance Measurement and Neurotransmitter Detection Channels.

    PubMed

    Dragas, Jelena; Viswam, Vijay; Shadmani, Amir; Chen, Yihui; Bounik, Raziyeh; Stettler, Alexander; Radivojevic, Milos; Geissler, Sydney; Obien, Marie; Müller, Jan; Hierlemann, Andreas

    2017-06-01

    Biological cells are characterized by highly complex phenomena and processes that are, to a great extent, interdependent. To gain detailed insights, devices designed to study cellular phenomena need to enable tracking and manipulation of multiple cell parameters in parallel; they have to provide high signal quality and high spatiotemporal resolution. To this end, we have developed a CMOS-based microelectrode array system that integrates six measurement and stimulation functions, the largest number to date. Moreover, the system features the largest active electrode array area to date (4.48×2.43 mm 2 ) to accommodate 59,760 electrodes, while its power consumption, noise characteristics, and spatial resolution (13.5 μm electrode pitch) are comparable to the best state-of-the-art devices. The system includes: 2,048 action-potential (AP, bandwidth: 300 Hz to 10 kHz) recording units, 32 local-field-potential (LFP, bandwidth: 1 Hz to 300 Hz) recording units, 32 current recording units, 32 impedance measurement units, and 28 neurotransmitter detection units, in addition to the 16 dual-mode voltage-only or current/voltage-controlled stimulation units. The electrode array architecture is based on a switch matrix, which allows for connecting any measurement/stimulation unit to any electrode in the array and for performing different measurement/stimulation functions in parallel.

  15. In vivo measurements of structure/electrode position changes during respiration for Electrical Impedance Tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Jie; Qin, Lihong; Allen, Tadashi; Patterson, Robert

    2010-04-01

    For pulmonary applications of EIT systems, the electrodes are placed around the chest in a 2D ring, and the images are reconstructed based on the assumptions that the object is rigid and the measured resistivity change in EIT images is only caused by the actual resistivity change of tissue. Structural changes are rarely considered. Previous studies have shown that structural changes which result in tissue/organ and electrode position change tend to introduce artifacts to EIT images of the thorax. Since EIT reconstruction is an ill-posed inverse problem, any inaccurate assumptions of object may cause large artifacts in reconstructed images. Accurate information on structure/electrode position changes is necessary to understand factors contributing to the measured resistivity changes and to improve EIT reconstruction algorithm. In this study, in vivo structure/electrode position changes from a healthy male volunteer are investigated during respiration cycle at two levels, the nipple line level and the level approximately 5 cm below. For each level, sixteen fiduciary markers are equally spaced around the surface, the same as the electrode placement for EIT measurements. A MR scanner with respiration-gated ability is used to acquire images of the thorax. MR thoracic images are prospectively acquired corresponding temporally to specific time periods within respiration cycle (FRC, mid tidal volume, tidal volume). The chest expansions in anterior-posterior and lateral directions and inside tissue/organ position changes are then analyzed. The electrode position changes corresponding to different phases of respiration cycle are also measured.

  16. Platelet impedance adhesiometry: A novel technique for the measurement of platelet adhesion and spreading.

    PubMed

    Polgár, L; Soós, P; Lajkó, E; Láng, O; Merkely, B; Kőhidai, L

    2018-06-01

    Thrombogenesis plays an important role in today's morbidity and mortality. Antithrombotics are among the most frequently prescribed drugs. Thorough knowledge of platelet function is needed for optimal clinical care. Platelet adhesion is a separate subprocess of platelet thrombus formation; still, no well-standardized technique for the isolated measurement of platelet adhesion exists. Impedimetry is one of the most reliable, state-of-art techniques to analyze cell adhesion, proliferation, viability, and cytotoxicity. We propose impedimetry as a feasible novel method for the isolated measurement of 2 significant platelet functions: adhesion and spreading. Laboratory reference platelet agonists (epinephrine, ADP, and collagen) were applied to characterize platelet functions by impedimetry using the xCELLigence SP system. Platelet samples were obtained from 20 healthy patients under no drug therapy. Standard laboratory parameters and clinical patient history were also analyzed. Epinephrine and ADP increased platelet adhesion in a concentration-dependent manner, while collagen tended to have a negative effect. Serum sodium and calcium levels and age had a negative correlation with platelet adhesion induced by epinephrine and ADP, while increased immunoreactivity connected with allergic diseases was associated with increased platelet adhesion induced by epinephrine and ADP. ADP increased platelet spreading in a concentration-dependent manner. Impedimetry proved to be a useful and sensitive method for the qualitative and quantitated measurement of platelet adhesion, even differentiating between subgroups of a healthy population. This novel technique is offered as an important method in the further investigation of platelet function. © 2018 John Wiley & Sons Ltd.

  17. Discrepancies between leg-to-leg bioelectrical Impedance analysis and computerized tomography in abdominal visceral fat measurement.

    PubMed

    Lu, Hsueh-Kuan; Chen, Yu-Yawn; Yeh, Chinagwen; Chuang, Chih-Lin; Chiang, Li-Ming; Lai, Chung-Liang; Casebolt, Kevin M; Huang, Ai-Chun; Lin, Wen-Long; Hsieh, Kuen-Chang

    2017-08-22

    The aim of this study was to evaluate leg-to-leg bioelectrical impedance analysis (LBIA) using a four-contact electrode system for measuring abdominal visceral fat area (VFA). The present study recruited 381 (240 male and 141 female) Chinese participants to compare VFA measurements estimated by a standing LBIA system (VFALBIA) with computerized tomography (CT) scanned at the L4-L5 vertebrae (VFA CT ). The total mean body mass index (BMI) was 24.7 ± 4.2 kg/m 2 . Correlation analysis, regression analysis, Bland-Altman plot, and paired sample t-tests were used to analyze the accuracy of the VFA LBIA . For the total subjects, the regression line was VFA LBIA  = 0.698 VFA CT  + 29.521, (correlation coefficient (r) = 0.789, standard estimate of error (SEE) = 24.470 cm 2 , p < 0.001), Lin's correlation coefficient (CCC) was 0.785; and the limit of agreement (LOA; mean difference ±2 standard deviation) ranged from -43.950 to 67.951 cm 2 , LOA% (given as a percentage of mean value measured by the CT) was 48.2%. VFA LBIA and VFA CT showed significant difference (p < 0.001). Collectively, the current study indicates that LBIA has limited potential to accurately estimate visceral fat in a clinical setting.

  18. Measurement of electrode-tissue interface impedance for improvement of a transcutaneous data transmission using human body as transmission medium.

    PubMed

    Okamoto, Eiji; Kato, Yoshikuni; Kikuchi, Sakiko; Mitamura, Yoshinori

    2014-01-01

    The electrical property between an electrode and skin or tissue is one of the important issues for communication performance of the transcutaneous communication system (TCS) using a human body as a conductive medium.In this study, we used a simple method to measure interface resistance between the electrode and skin on the surface of the body. The electrode-electrode impedance was measured by a commercially available LCR meter with changes in the distance between two electrodes on an arm of a healthy male subject, and we obtained the tissue resistivity and electrode-skin interface resistance using the cross-sectional area of the arm.We also measured transmission gain of the TCS on the surface of the body, and we investigated the relationship between electrode-skin interface resistance and transmission gain. We examined four kinds of electrodes: a stainless steel electrode, a titanium electrode, an Ag-AgCl electrode and an Ag-AgCl paste electrode. The stainless steel electrode, which had lower electrode-skin resistance, had higher transmission gain.The results indicate that an electrode that has lower electrode-skin resistance will contribute to improvement of the performance of the TCS and that electrode-skin interface resistance is one of valuable evaluation parameters for selecting an optimum electrode for the TCS.

  19. Optically stimulated differential impedance spectroscopy

    DOEpatents

    Maxey, Lonnie C; Parks, II, James E; Lewis, Sr., Samuel A; Partridge, Jr., William P

    2014-02-18

    Methods and apparatuses for evaluating a material are described. Embodiments typically involve use of an impedance measurement sensor to measure the impedance of a sample of the material under at least two different states of illumination. The states of illumination may include (a) substantially no optical stimulation, (b) substantial optical stimulation, (c) optical stimulation at a first wavelength of light, (d) optical stimulation at a second wavelength of light, (e) a first level of light intensity, and (f) a second level of light intensity. Typically a difference in impedance between the impedance of the sample at the two states of illumination is measured to determine a characteristic of the material.

  20. Cross-sectional changes in lung volume measured by electrical impedance tomography are representative for the whole lung in ventilated preterm infants.

    PubMed

    van der Burg, Pauline S; Miedema, Martijn; de Jongh, Frans H; Frerichs, Inez; van Kaam, Anton H

    2014-06-01

    Electrical impedance tomography measures lung volume in a cross-sectional slice of the lung. Whether these cross-sectional volume changes are representative of the whole lung has only been investigated in adults, showing conflicting results. This study aimed to compare cross-sectional and whole lung volume changes using electrical impedance tomography and respiratory inductive plethysmography. A prospective, single-center, observational, nonrandomized study. The study was conducted in a neonatal ICU in the Netherlands. High-frequency ventilated preterm infants with respiratory distress syndrome. Cross-sectional and whole lung volume changes were continuously and simultaneously measured by, respectively, electrical impedance tomography and respiratory inductive plethysmography during a stepwise recruitment procedure. End-expiratory lung volume changes were assessed by mapping the inflation and deflation limbs using both the pressure/impedance and pressure/inductance pairs and characterized by calculating the inflection points. In addition, oscillatory tidal volume changes were assessed at each pressure step. Twenty-three infants were included in the study. Of these, eight infants had to be excluded because the quality of the registration was insufficient for analysis (two electrical impedance tomography and six respiratory inductive plethysmography). In the remaining 15 infants (gestational age 28.0 ± 2.6 wk; birth weight 1,027 ± 514 g), end-expiratory lung volume changes measured by electrical impedance tomography were significantly correlated to respiratory inductive plethysmography measurements in 12 patients (mean r = 0.93 ± 0.05). This was also true for the upper inflection point on the inflation (r = 0.91, p < 0.01) and deflation limb (r = 0.83, p < 0.01). In 13 patients, impedance and inductance data also correlated significantly on oscillatory tidal volume/pressure relationships (mean r = 0.81 ± 0.18). This study shows that cross-sectional lung volume

  1. Application of non-invasive cerebral electrical impedance measurement on brain edema in patients with cerebral infarction.

    PubMed

    He, Lan Ying; Wang, Jian; Luo, Yong; Dong, Wei Wei; Liu, Li Xu

    2010-09-01

    To investigate the change of brain edema in patients with cerebral infarction by non-invasive cerebral electrical impedance (CEI) measurements. An invariable secure current at a frequency of 50 kHz and an intensity of 0.1 mA was given into a person's brain. CEI values of the bilateral hemisphere of 200 healthy volunteers and 107 patients with cerebral infarction were measured by non-invasive brain edema monitor. The results of perturbative index (PI) converted from CEI were compared with the volumes of brain edema, which were calculated by an image analysing system according to magnetic resonance imaging or computed tomography. (1) In the healthy volunteers, PI values in the left and right hemisphere were 7.98 +/- 0.95 and 8.02 +/- 0.71 respectively, and there was no significant difference between the two sides (p>0.05). Age, gender and different measuring times did not obviously affect PI values (p>0.05). (2) In the cerebral infarction group, CEI measurements were more sensitive to the volumes of lesion, which were more than 20 ml. The positive ratio of PI was higher when the volumes of infarction were >20 ml (80.0%): the ratio of PI was 75.9% when the volumes of infarction were 20-50 ml and it was 83.3% when the volumes of lesion were more than 50 ml. PI was lower when the volumes were less than 20 ml. (3) PI of the infarction side increased obviously 3-5 days after onset; the difference of two sides was the most significant. There was a positive correlation between PI of the infarction side and volume of infarction. PI may be a sensitive parameter for non-invasive monitoring of the change of brain edema in patients with cerebral infarction. CEI is a valuable method for the early detection of brain edema.

  2. Impedance analysis of GPCR-mediated changes in endothelial barrier function: overview, and fundamental considerations for stable and reproducible measurements

    PubMed Central

    Stolwijk, Judith A.; Matrougui, Khalid; Renken, Christian W.; Trebak, Mohamed

    2014-01-01

    The past 20 years have seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists, pharmacological and toxicological compounds. Most studies on barrier function use G protein coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance based techniques such as Electric Cell-Substrate Impedance Sensing (ECIS) reside in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine and Sphingosine-1-Phosphate. PMID:25537398

  3. Impedance analysis of GPCR-mediated changes in endothelial barrier function: overview and fundamental considerations for stable and reproducible measurements.

    PubMed

    Stolwijk, Judith A; Matrougui, Khalid; Renken, Christian W; Trebak, Mohamed

    2015-10-01

    The past 20 years has seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists and pharmacological and toxicological compounds. Most studies on barrier function use G protein-coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance-based techniques such as electric cell-substrate impedance sensing (ECIS) resides in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications, and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research, little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency, or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling, and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine, and sphingosine-1-phosphate.

  4. Design and optimization of a noise reduction system for infrasonic measurements using elements with low acoustic impedance.

    PubMed

    Alcoverro, Benoit; Le Pichon, Alexis

    2005-04-01

    The implementation of the infrasound network of the International Monitoring System (IMS) for the enforcement of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) increases the effort in the design of suitable noise reducer systems. In this paper we present a new design consisting of low impedance elements. The dimensioning and the optimization of this discrete mechanical system are based on numerical simulations, including a complete electroacoustical modeling and a realistic wind-noise model. The frequency response and the noise reduction obtained for a given wind speed are compared to statistical noise measurements in the [0.02-4] Hz frequency band. The effects of the constructive parameters-the length of the pipes, inner diameters, summing volume, and number of air inlets-are investigated through a parametric study. The studied system consists of 32 air inlets distributed along an overall diameter of 16 m. Its frequency response is flat up to 4 Hz. For a 2 m/s wind speed, the maximal noise reduction obtained is 15 dB between 0.5 and 4 Hz. At lower frequencies, the noise reduction is improved by the use of a system of larger diameter. The main drawback is the high-frequency limitation introduced by acoustical resonances inside the pipes.

  5. Silicon Photoelectrode Thermodynamics and Hydrogen Evolution Kinetics Measured by Intensity-Modulated High-Frequency Resistivity Impedance Spectroscopy

    SciTech Connect

    Anderson, Nicholas C.; Carroll, Gerard M.; Pekarek, Ryan T.

    Here, we present an impedance technique based on light intensity-modulated high-frequency resistivity (IMHFR) that provides a new way to elucidate both the thermodynamics and kinetics in complex semiconductor photoelectrodes. We apply IMHFR to probe electrode interfacial energetics on oxide-modified semiconductor surfaces frequently used to improve the stability and efficiency of photoelectrochemical water splitting systems. Combined with current density-voltage measurements, the technique quantifies the overpotential for proton reduction relative to its thermodynamic potential in Si photocathodes coated with three oxides (SiO x, TiO 2, and Al 2O 3) and a Pt catalyst. In pH 7 electrolyte, the flatband potentials of TiOmore » 2- and Al 2O 3-coated Si electrodes are negative relative to samples with native SiO x, indicating that SiO x is a better protective layer against oxidative electrochemical corrosion than ALD-deposited crystalline TiO 2 or Al 2O 3. Adding a Pt catalyst to SiO x/Si minimizes proton reduction overpotential losses but at the expense of a reduction in available energy characterized by a more negative flatband potential relative to catalyst-free SiO x/Si.« less

  6. Measuring the shock impedance mismatch between high-density carbon and deuterium at the National Ignition Facility

    SciTech Connect

    Millot, M.; Celliers, P. M.; Sterne, P. A.

    Fine-grained diamond, or high-density carbon (HDC), is being used as an ablator for inertial confinement fusion (ICF) research at the National Ignition Facility (NIF). Accurate equation of state (EOS) knowledge over a wide range of phase space is critical in the design and analysis of integrated ICF experiments. Here in this paper, we report shock and release measurements of the shock impedance mismatch between HDC and liquid deuterium conducted during shock-timing experiments having a first shock in the ablator ranging between 8 and 14 Mbar. Using ultrafast Doppler imaging velocimetry to track the leading shock front, we characterize the shockmore » velocity discontinuity upon the arrival of the shock at the HDC/liquid deuterium interface. Comparing the experimental data with tabular EOS models used to simulate integrated ICF experiments indicates the need for an improved multiphase EOS model for HDC in order to achieve a significant increase in neutron yield in indirect-driven ICF implosions with HDC ablators.« less

  7. Measuring the shock impedance mismatch between high-density carbon and deuterium at the National Ignition Facility

    DOE PAGES

    Millot, M.; Celliers, P. M.; Sterne, P. A.; ...

    2018-04-18

    Fine-grained diamond, or high-density carbon (HDC), is being used as an ablator for inertial confinement fusion (ICF) research at the National Ignition Facility (NIF). Accurate equation of state (EOS) knowledge over a wide range of phase space is critical in the design and analysis of integrated ICF experiments. Here in this paper, we report shock and release measurements of the shock impedance mismatch between HDC and liquid deuterium conducted during shock-timing experiments having a first shock in the ablator ranging between 8 and 14 Mbar. Using ultrafast Doppler imaging velocimetry to track the leading shock front, we characterize the shockmore » velocity discontinuity upon the arrival of the shock at the HDC/liquid deuterium interface. Comparing the experimental data with tabular EOS models used to simulate integrated ICF experiments indicates the need for an improved multiphase EOS model for HDC in order to achieve a significant increase in neutron yield in indirect-driven ICF implosions with HDC ablators.« less

  8. A Liquid Level Measurement Technique Outside a Sealed Metal Container Based on Ultrasonic Impedance and Echo Energy

    PubMed Central

    Zhang, Bin; Wei, Yue-Juan; Liu, Wen-Yi; Zhang, Yan-Jun; Yao, Zong; Zhao, Li-Hui; Xiong, Ji-Jun

    2017-01-01

    The proposed method for measuring the liquid level focuses on the ultrasonic impedance and echo energy inside a metal wall, to which the sensor is attached directly, not on ultrasonic waves that penetrate the gas–liquid medium of a container. Firstly, by analyzing the sound field distribution characteristics of the sensor in a metal wall, this paper proposes the concept of an "energy circle" and discusses how to calculate echo energy under three different states in detail. Meanwhile, an ultrasonic transmitting and receiving circuit is designed to convert the echo energy inside the energy circle into its equivalent electric power. Secondly, in order to find the two critical states of the energy circle in the process of liquid level detection, a program is designed to help with calculating two critical positions automatically. Finally, the proposed method is evaluated through a series of experiments, and the experimental results indicate that the proposed method is effective and accurate in calibration of the liquid level outside a sealed metal container. PMID:28106857

  9. Silicon Photoelectrode Thermodynamics and Hydrogen Evolution Kinetics Measured by Intensity-Modulated High-Frequency Resistivity Impedance Spectroscopy

    DOE PAGES

    Anderson, Nicholas C.; Carroll, Gerard M.; Pekarek, Ryan T.; ...

    2017-10-05

    Here, we present an impedance technique based on light intensity-modulated high-frequency resistivity (IMHFR) that provides a new way to elucidate both the thermodynamics and kinetics in complex semiconductor photoelectrodes. We apply IMHFR to probe electrode interfacial energetics on oxide-modified semiconductor surfaces frequently used to improve the stability and efficiency of photoelectrochemical water splitting systems. Combined with current density-voltage measurements, the technique quantifies the overpotential for proton reduction relative to its thermodynamic potential in Si photocathodes coated with three oxides (SiO x, TiO 2, and Al 2O 3) and a Pt catalyst. In pH 7 electrolyte, the flatband potentials of TiOmore » 2- and Al 2O 3-coated Si electrodes are negative relative to samples with native SiO x, indicating that SiO x is a better protective layer against oxidative electrochemical corrosion than ALD-deposited crystalline TiO 2 or Al 2O 3. Adding a Pt catalyst to SiO x/Si minimizes proton reduction overpotential losses but at the expense of a reduction in available energy characterized by a more negative flatband potential relative to catalyst-free SiO x/Si.« less

  10. TSDC and impedance spectroscopy measurements on hydroxyapatite, β-tricalcium phosphate and hydroxyapatite/β-tricalcium phosphate biphasic bioceramics

    NASA Astrophysics Data System (ADS)

    Prezas, P. R.; Melo, B. M. G.; Costa, L. C.; Valente, M. A.; Lança, M. C.; Ventura, J. M. G.; Pinto, L. F. V.; Graça, M. P. F.

    2017-12-01

    Bone grafting and surgical interventions related with orthopaedic disorders consist in a big business, generating large revenues worldwide every year. There is a need to replace the biomaterials that currently still dominate this market, i.e., autografts and allografts, due to their disadvantages, such as limited availability, need for additional surgeries and diseases transmission possibilities. The most promising replacement materials are biomaterials with bioactive properties, such as the calcium phosphate-based bioceramics group. The bioactivity of these materials, i.e., the rate at which they promote the growth and directly bond with the new host biological bone, can be enhanced through their electrical polarization. In the present work, the electrical polarization features of pure hydroxyapatite (Hap), pure β-tricalcium phosphate (β-TCP) and biphasic hydroxyapatite/β-tricalcium phosphate composites (HTCP) were analyzed by measuring thermally stimulated depolarization currents (TSDC). The samples were thermoelectrically polarized at 500 °C under a DC electric field with a magnitude of 5 kV/cm. The biphasic samples were also polarized under electric fields with different magnitudes: 2, 3, 4 and 5 kV/cm. Additionally, the depolarization processes detected in the TSDC measurements were correlated with dielectric relaxation processes observed in impedance spectroscopy (IS) measurements. The results indicate that the β-TCP crystalline phase has a considerable higher ability to store electrical charge compared with the Hap phase. This indicates that it has a suitable composition and structure for ionic conduction and establishment of a large electric charge density, providing great potential for orthopaedic applications.

  11. Lead field theory provides a powerful tool for designing microelectrode array impedance measurements for biological cell detection and observation.

    PubMed

    Böttrich, Marcel; Tanskanen, Jarno M A; Hyttinen, Jari A K

    2017-06-26

    Our aim is to introduce a method to enhance the design process of microelectrode array (MEA) based electric bioimpedance measurement systems for improved detection and viability assessment of living cells and tissues. We propose the application of electromagnetic lead field theory and reciprocity for MEA design and measurement result interpretation. Further, we simulated impedance spectroscopy (IS) with two- and four-electrode setups and a biological cell to illustrate the tool in the assessment of the capabilities of given MEA electrode constellations for detecting cells on or in the vicinity of the microelectrodes. The results show the power of the lead field theory in electromagnetic simulations of cell-microelectrode systems depicting the fundamental differences of two- and four-electrode IS measurement configurations to detect cells. Accordingly, the use in MEA system design is demonstrated by assessing the differences between the two- and four-electrode IS configurations. Further, our results show how cells affect the lead fields in these MEA system, and how we can utilize the differences of the two- and four-electrode setups in cell detection. The COMSOL simulator model is provided freely in public domain as open source. Lead field theory can be successfully applied in MEA design for the IS based assessment of biological cells providing the necessary visualization and insight for MEA design. The proposed method is expected to enhance the design and usability of automated cell and tissue manipulation systems required for bioreactors, which are intended for the automated production of cell and tissue grafts for medical purposes. MEA systems are also intended for toxicology to assess the effects of chemicals on living cells. Our results demonstrate that lead field concept is expected to enhance also the development of such methods and devices.

  12. Predicting total weight of retail-ready lamb cuts from bioelectrical impedance measurements taken at the processing plant.

    PubMed

    Slanger, W D; Marchello, M J; Busboom, J R; Meyer, H H; Mitchell, L A; Hendrix, W F; Mills, R R; Warnock, W D

    1994-06-01

    Data of sixty finished, crossbred lambs were used to develop prediction equations of total weight of retail-ready cuts (SUM). These cuts were the leg, sirloin, loin, rack, shoulder, neck, riblets, shank, and lean trim (85/15). Measurements were taken on live lambs and on both hot and cold carcasses. A four-terminal bioelectrical impedance analyzer (BIA) was used to measure resistance (Rs, ohms) and reactance (Xc, ohms). Distances between detector terminals (L, centimeters) were recorded. Carcass temperatures (T, degrees C) at time of BIA readings were also recorded. The equation predicting SUM from cold carcass measurements (n = 53, R2 = .97) was .093 + .621 x weight-.0219 x Rs + .0248 x Xc + .182 x L-.338 x T. Resistance accounted for variability in SUM over and above weight and L (P = .0016). The above equation was used to rank cold carcasses in descending order of predicted SUM. An analogous ranking was obtained from a prediction equation that used weight only (R2 = .88). These rankings were divided into five categories: top 25%, middle 50%, bottom 25%, top 50%, and bottom 50%. Within-category differences in average fat cover, yield grade, and SUM as a percentage of cold carcass weight of carcasses not placed in the same category by both prediction equations were quantified with independent t-tests. These differences were statistically significant for all categories except middle 50%. This shows that BIA located those lambs that could more efficiently contribute to SUM because a higher portion of their weight was lean.

  13. Validity of Bioelectrical Impedance Analysis for Measuring Changes in Body Water and Percent Fat After Bariatric Surgery

    PubMed Central

    Widen, Elizabeth M.; Strain, Gladys; King, Wendy C.; Yu, Wenwen; Lin, Susan; Goodpaster, Bret; Thornton, John; Courcoulas, Anita; Pomp, Alfons

    2014-01-01

    Background Few studies have validated bioelectrical impedance analysis (BIA) following bariatric surgery. Methods We examined agreement of BIA (Tanita 310) measures of total body water (TBW) and percent body fat (%fat) before (T0) and 12 months (T12) after bariatric surgery, and change between T0 and T12 with reference measures: deuterium oxide dilution for TBW and three-compartment model (3C) for %fat in a subset of participants (n=50) of the Longitudinal Assessment of Bariatric Surgery-2. Results T0 to T12 median (IQR) change in deuterium TBW and 3C %fat was −6.4 L (6.4 L) and −14.8 % (13.4 %), respectively. There were no statistically significant differences between deuterium and BIA determined TBW [median (IQR) difference: T0 −0.1 L (7.1 L), p=0.75; T12 0.2 L (5.7 L), p=0.35; Δ 0.35 L(6.3 L), p=1.0]. Compared with 3C, BIA underestimated %fat at T0 and T12 [T0 −3.3 (5.6), p<0.001; T12 −1.7 (5.2), p=0.04] but not change [0.7 (8.2), p=0.38]. Except for %fat change, Bland-Altman plots indicated no proportional bias. However, 95 % limits of agreement were wide (TBW 15–22 L, %fat 19–20 %). Conclusions BIA may be appropriate for evaluating group level response among severely obese adults. However, clinically meaningful differences in the accuracy of BIA between individuals exist. PMID:24464517

  14. Could bioelectric impedance spectroscopy (BIS) measured appendicular intracellular water serve as a lean mass measurement in sarcopenia definitions? A pilot study.

    PubMed

    Siglinsky, E; Buehring, B; Krueger, D; Binkley, N; Yamada, Y

    2018-03-25

    DXA lean mass measurement for sarcopenia diagnosis is not always possible. Bioelectric impedance spectroscopy (BIS), a portable technology, is a potential alternative to DXA-measured lean mass. This pilot study explores the possibility and proposes an arbitrarily chosen potential cut-point for appendicular intracellular water corrected by height (aICW/ht 2 ). Sarcopenia definitions often include DXA lean mass measurement. However, DXA is not always available. We explored the potential of a less-expensive mobile method, bioelectric impedance spectroscopy (BIS), to assess lean mass for sarcopenia determination. We hypothesized that BIS-measured appendicular intracellular water (aICW/ht 2 ) would correlate with DXA-measured appendicular lean mass (ALM)/ht 2 and with functional parameters. If so, establishing an aICW/ht 2 cut-point in sarcopenia definitions may be feasible. Sixty-one community-dwelling women, mean age 79.9, had BIS and DXA lean mass, grip strength, gait speed, and jumping mechanography assessments. BIS aICW was calculated using limb length and intracellular water resistance. aICW/ht 2 was compared to DXA-measured ALM/ht 2 by linear regression. The European Working Group ALM/ht 2 and an exploratory aICW/ht 2 cut-point were utilized. In this cohort, ALM/ht 2 and aICW/ht 2 were moderately correlated, R 2  = 0.55, p < 0.0001. Lean mass was low in 7 and normal in 44 by BIS and DXA. Those with low aICW/ht 2 had lower grip strength (p = 0.04) and jump power (p = 0.0002) than those with normal aICW/ht 2 and ALM/ht 2 . Subjects with low ALM/ht 2 had lower jump power (p = 0.0006) but were not different in gait speed or grip strength. BIS aICW is correlated with DXA-measured ALM directly, and when height adjusted. An aICW/ht 2 cut-point of 6.5 L/m 2 identified 70% of women with low ALM/ht 2 . Women with low lean mass by DXA and BIS had poorer function measured by jump power. These pilot data support further evaluation of BIS measurement

  15. Coupled field modeling of E/M impedance of piezoelectric wafer active sensor for cataphoretic coating thickness measurement

    NASA Astrophysics Data System (ADS)

    Kamas, T.; Tekkalmaz, M.

    2017-04-01

    The cataphoretic electro-coating is one of the most common methods that are used against corrosion as a primary coating layer. The cataphoretic electro-coating is commonly utilized technique especially in protecting of automobile components in automotive industry. This coating method has many advantages such as high corrosion resistance, ability of homogeneous and complete coating of components in any geometry, less pollution, and less risk of ignition. In this study, some specimens in the form of steel sheets coated by the cataphoretic electro-coating method are examined using electro-mechanical impedance spectroscopy (EMIS) method. One of the extensively employed sensor technologies has been permanently installed piezoelectric wafer active sensor (PWAS) for in situ continuous structural health monitoring (SHM). Using the transduction of ultrasonic elastic waves into voltage and vice versa, PWAS has been emerged as one of the major SHM sensing technologies. EMIS method has been utilized as a dynamic descriptor of PWAS and the structure on which it is bonded. EMIS of PWAS-structure couple is a high frequency local modal sensing technique by applying standing waves to indicate the response of the PWAS resonator by determining the resonance and anti-resonance frequencies. To simulate the actual EMIS measurements in the present work, two-dimensional and three-dimensional coupled field finite element models are created for both uncoated and coated steel plates in a commercial FEA software, ANSYS®. The EMIS values of the specimens in certain sizes and coated in different thickness are going to be simulated in broad-band of frequency spectra. The thickness of the coating layer and coating time are of paramount importance for the corrosion resistance. The coating layer thickness and the corresponding coating period will be optimized by analyses of the values obtained from the 2D and 3D EMIS simulations.

  16. Obesity in Korean pre-adolescent school children: comparison of various anthropometric measurements based on bioelectrical impedance analysis.

    PubMed

    Yoo, S; Lee, S-Y; Kim, K-N; Sung, E

    2006-07-01

    To examine the relationships between body mass index (BMI), percentage-weight-for-height (PWH) and percentage body fat (PBF), and to compare their validity based on PBF with the BMI criteria of International Obesity Task Force (IOTF) for childhood obesity in Korean pre-adolescent school children. Statistical comparative analysis for anthropometric measures. Korean pre-adolescent children (438 boys and 454 girls, aged 8-12 years, mean BMI 19.5+/-3.4 kg/m2). Body mass index and PWH were calculated as body size indices from height and weight. Hand-to-foot bioelectrical impedance analysis (BIA) was performed to obtain PBF values, with obese children defined as PBF above 35%. Sensitivity and specificity were displayed with the gold standard of PBF, and receiver operating characteristic (ROC) curves were used to assess the performance of BMI and PWH in detecting obesity. The prevalence of obesity varied by the criteria: 18.8% by Korean BMI standards for 95 percentile, 11% by the IOTF-BMI 30 kg/m2 and 29.4% by Korean PWH cutoffs. Body mass index and PWH were significantly correlated with PBF after adjusting for age, 0.910 (P<0.01) and 0.915 (P<0.01), respectively. The sensitivity and specificity of the PWH cutoffs were 0.909 and 0.882, respectively. The local BMI 95 percentiles had lower sensitivity (0.714) and specificity (0.790). The IOTF-BMI definition showed much lower sensitivity (0.457) and higher specificity (0.990). The BMI cutoffs corresponding with the highest accuracy were smaller than IOTF-BMI 30 kg/m2 for all age groups in both boys and girls. The prevalence of obesity among Korean pre-adolescent children widely varied according to the diagnostic criteria applied. Universally recommended cutoffs for children by IOTF showed the lowest sensitivity among the criteria used, and may therefore underestimate obesity in this population.

  17. Feasibility and acceptability of a self-measurement using a portable bioelectrical impedance analysis, by the patient with chronic heart failure, in acute decompensated heart failure.

    PubMed

    Huguel, Benjamin; Vaugrenard, Thibaud; Saby, Ludivine; Benhamou, Lionel; Arméro, Sébastien; Camilleri, Élise; Langar, Aida; Alitta, Quentin; Grino, Michel; Retornaz, Frédérique

    2018-06-01

    Chronic heart failure (CHF) is a major public health matter. Mainly affecting the elderly, it is responsible for a high rate of hospitalization due to the frequency of acute heart failure (ADHF). This represents a disabling pathology for the patient and very costly for the health care system. Our study is designed to assess a connected and portable bioelectrical impedance analysis (BIA) that could reduce these hospitalizations by preventing early ADHF. This prospective study included patients hospitalized in cardiology for ADHF. Patients achieved 3 self-measurements using the BIA during their hospitalization and answered a questionnaire evaluating the acceptability of this self-measurement. The results of these measures were compared with the clinical, biological and echocardiographic criteria of patients at the same time. Twenty-three patients were included, the self-measurement during the overall duration of the hospitalization was conducted autonomously by more than 80% of the patients. The acceptability (90%) for the use of the portable BIA was excellent. Some correlations were statistically significant, such as the total water difference to the weight difference (p=0.001). There were common trends between the variation of impedance analysis measures and other evaluation criteria. The feasibility and acceptability of a self-measurement of bioelectrical impedance analysis by the patient in AHF opens up major prospects in the management of monitoring patients in CHF. The interest of this tool is the prevention of ADHF leading to hospitalization or re-hospitalizations now requires to be presented by new studies.

  18. Measurement of electrical impedance of a Berea sandstone core during the displacement of saturated brine by oil and CO2 injections

    NASA Astrophysics Data System (ADS)

    Liu, Yu; Xue, Ziqiu; Park, Hyuck; Kiyama, Tamotsu; Zhang, Yi; Nishizawa, Osamu; Chae, Kwang-seok

    2015-12-01

    Complex electrical impedance measurements were performed on a brine-saturated Berea sandstone core while oil and CO2 were injected at different pressures and temperatures. The saturations of brine, oil, and CO2 in the core were simultaneously estimated using an X-ray computed tomography scanner. The formation factor of this Berea core and the resistivity indexes versus the brine saturations were calculated using Archie's law. The experimental results found different flow patterns of oil under different pressures and temperatures. Fingers were observed for the first experiment at 10 MPa and 40 °C. The fingers were restrained as the viscosity ratio of oil and water changed in the second (10 MPa and 25 °C) and third (5 MPa and 25 °C) experiments. The resistivity index showed an exponential increase with a decrease in brine saturation. The saturation exponent varied from 1.4 to 4.0 at different pressure and temperature conditions. During the oil injection procedure, the electrical impedance increased with oil saturation and was significantly affected by different oil distributions; therefore, the impedance varied whether the finger was remarkable or not, even if the oil saturation remained constant. During the CO2 injection steps, the impedance showed almost no change with CO2 saturation because the brine in the pores became immobile after the oil injection.

  19. Hemodynamic response to exercise as measured by the solar IKG impedance cardiography module and correlation with metabolic variables.

    PubMed

    Ziegeler, Stephan; Grundmann, Ulrich; Fuerst, Oliver; Raddatz, Alexander; Kreuer, Sascha

    2007-02-01

    Impedance Cardiography (ICG) has been shown to be a feasible and accurate method for non-invasive measurement of cardiac index (CI). Aim of this investigation was the correlation of hemodynamic variables under exercise as measured by a specific ICG-monitor (Solar IKG-Modul, Version 3.0, GE-Healthcare, Freiburg, Germany) with metabolic variables. Ten healthy volunteers were included in the investigation doing ergometer exercise (5 min equilibration followed by 5 min each at 50, 75, 100 and 125 W). Hemodynamic parameters were obtained by ICG. Metabolic variables were assessed by indirect calorimetry with the Deltatrac II Metabolic monitor using a helmet system for spontaneous respiration. CI increased throughout exercise (baseline: 3.0 +/- 0.4 l/min/m(2); 125 W: 4.8 +/- 0.5 l/min/m(2)). Heart rate (baseline: 87.2 +/- 13.4 bpm; 125 W: 152.7 +/- 22.4 bpm) and contractility (velocity index) (baseline: 48.9 +/- 9.3/1000 s; 125 W: 70.5 +/- 10.0/1000 s) showed a continuous rise while the stroke index decreased after an initial rise (baseline: 35.0 +/- 4.6 ml/m(2); 50 W: 37.6 +/- 4.9 ml/m(2); 75 W: 41.2 +/- 5.9 ml/m(2); 125 W: 32.3 +/- 6.1 ml/m(2)). VO(2) (baseline: 335.2 +/- 84.1 ml/min; 125 W: 1298.9 +/- 282.3 ml/min) and VCO(2)(baseline: 255.4 +/- 74.5 ml/min; 125 W: 1342.5 +/- 282.5 ml/min) increased throughout exercise. There was a good correlation in the individual fits between hemodynamic and metabolic variables. CI in healthy volunteers, as measured by the Solar IKG-Modul, correlates well with O(2)-consumption and CO(2)-production in individual subjects, thus indicating the metabolic needs under exercise conditions in healthy individuals.

  20. Electrical impedance spectroscopy for quality assessment of meat and fish: A review on basic principles, measurement methods, and recent advances

    USDA-ARS?s Scientific Manuscript database

    Electrical impedance spectroscopy (EIS), as an effective analytical technique for electrochemical system, has shown a wide application for food quality and safety assessment recently. Individual differences of livestock cause high variation in quality of raw meat and fish and their commercialized pr...

  1. The use of electrochemical impedance spectroscopy (EIS) to measure the corrosion of metals in contact with wood

    Treesearch

    Samuel L. Zelinka; Douglas R. Rammer

    2005-01-01

    Although preservative treatments prolong the life of wood, they can also contribute to the corrosion of fasteners. The corrosion of fasteners merits further study because it can affect the long-term durability of structures and fundamental knowledge of corrosion in wood is limited. The goal of this study is to determine the viability of electrochemical impedance...

  2. Pulmonary vascular input impedance is a combined measure of pulmonary vascular resistance and stiffness and predicts clinical outcomes better than pulmonary vascular resistance alone in pediatric patients with pulmonary hypertension.

    PubMed

    Hunter, Kendall S; Lee, Po-Feng; Lanning, Craig J; Ivy, D Dunbar; Kirby, K Scott; Claussen, Lori R; Chan, K Chen; Shandas, Robin

    2008-01-01

    Pulmonary vascular resistance (PVR) is the current standard for evaluating reactivity in children with pulmonary arterial hypertension (PAH). However, PVR measures only the mean component of right ventricular afterload and neglects pulsatile effects. We recently developed and validated a method to measure pulmonary vascular input impedance, which revealed excellent correlation between the zero harmonic impedance value and PVR and suggested a correlation between higher-harmonic impedance values and pulmonary vascular stiffness. Here we show that input impedance can be measured routinely and easily in the catheterization laboratory, that impedance provides PVR and pulmonary vascular stiffness from a single measurement, and that impedance is a better predictor of disease outcomes compared with PVR. Pressure and velocity waveforms within the main pulmonary artery were measured during right heart catheterization of patients with normal pulmonary artery hemodynamics (n = 14) and those with PAH undergoing reactivity evaluation (49 subjects, 95 conditions). A correction factor needed to transform velocity into flow was obtained by calibrating against cardiac output. Input impedance was obtained off-line by dividing Fourier-transformed pressure and flow waveforms. Exceptional correlation was found between the indexed zero harmonic of impedance and indexed PVR (y = 1.095x + 1.381, R2 = 0.9620). In addition, the modulus sum of the first 2 harmonics of impedance was found to best correlate with indexed pulse pressure over stroke volume (y = 13.39x - 0.8058, R2 = 0.7962). Among a subset of patients with PAH (n = 25), cumulative logistic regression between outcomes to total indexed impedance was better (R(L)2 = 0.4012) than between outcomes and indexed PVR (R(L)2 = 0.3131). Input impedance can be consistently and easily obtained from pulse-wave Doppler and a single catheter pressure measurement, provides comprehensive characterization of the main components of RV afterload, and

  3. Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study

    PubMed Central

    Richard, JC; Pouzot, C; Gros, A; Tourevieille, C; Lebars, D; Lavenne, F; Frerichs, I; Guérin, C

    2009-01-01

    Introduction Electrical impedance tomography (EIT), which can assess regional lung ventilation at the bedside, has never been compared with positron-emission tomography (PET), a gold-standard to quantify regional ventilation. This experiment systematically compared both techniques in injured and non-injured lungs. Methods The study was performed in six mechanically ventilated female piglets. In normal lungs, tidal volume (VT) was randomly changed to 6, 8, 10 and 15 ml/kg on zero end-expiratory pressure (ZEEP), then, at VT 10 ml/kg, positive end-expiratory pressure (PEEP) was randomly changed to 5, 10 and 15 cmH2O. Afterwards, acute lung injury (ALI) was subsequently created in three animals by injecting 3 ml/kg hydrochloric acid into the trachea. Then at PEEP 5 cmH2O, VT was randomly changed to 8 and 12 ml/kg and PEEP of 10 and 15 cmH2O applied at VT 10 ml/kg. EIT and PET examinations were performed simultaneously. EIT ventilation (VTEIT) and lung volume (VL) were measured in the anterior and posterior area of each lung. On the same regions of interest, ventilation (VPET) and aerated lung volume (VAatten) were determined with PET. Results On ZEEP, VTEIT and VPET significantly correlated for global (VTEIT = VPET - 2E-13, R2 = 0.95, P < 0.001) and regional (VTEIT = 0.81VPET+7.65, R2 = 0.63, P < 0.001) ventilation over both conditions. For ALI condition, corresponding R2 were 0.91 and 0.73 (P < 0.01). Bias was = 0 and limits of agreement were -37.42 and +37.42 ml/min for global ventilation over both conditions. These values were 0.04 and -29.01 and +29.08 ml/min, respectively, for regional ventilation. Significant correlations were also found between VL and VAatten for global (VL = VAatten+1E-12, R2 = 0.93, P < 0.0001) and regional (VL = 0.99VAatten+0.92, R2 = 0.65, P < 0.001) volume. For ALI condition, corresponding R2 were 0.94 (P < 0.001) and 0.54 (P < 0.05). Bias was = 0 and limits of agreement ranged -38.16 and +38.16 ml for global ventilation over both

  4. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.

    PubMed

    Spadaro, Savino; Mauri, Tommaso; Böhm, Stephan H; Scaramuzzo, Gaetano; Turrini, Cecilia; Waldmann, Andreas D; Ragazzi, Riccardo; Pesenti, Antonio; Volta, Carlo Alberto

    2018-01-31

    Assessing alveolar recruitment at different positive end-expiratory pressure (PEEP) levels is a major clinical and research interest because protective ventilation implies opening the lung without inducing overdistention. The pressure-volume (P-V) curve is a validated method of assessing recruitment but reflects global characteristics, and changes at the regional level may remain undetected. The aim of the present study was to compare, in intubated patients with acute hypoxemic respiratory failure (AHRF) and acute respiratory distress syndrome (ARDS), lung recruitment measured by P-V curve analysis, with dynamic changes in poorly ventilated units of the dorsal lung (dependent silent spaces [DSSs]) assessed by electrical impedance tomography (EIT). We hypothesized that DSSs might represent a dynamic bedside measure of recruitment. We carried out a prospective interventional study of 14 patients with AHRF and ARDS admitted to the intensive care unit undergoing mechanical ventilation. Each patient underwent an incremental/decremental PEEP trial that included five consecutive phases: PEEP 5 and 10 cmH 2 O, recruitment maneuver + PEEP 15 cmH 2 O, then PEEP 10 and 5 cmH 2 O again. We measured, at the end of each phase, recruitment from previous PEEP using the P-V curve method, and changes in DSS were continuously monitored by EIT. PEEP changes induced alveolar recruitment as assessed by the P-V curve method and changes in the amount of DSS (p < 0.001). Recruited volume measured by the P-V curves significantly correlated with the change in DSS (r s  = 0.734, p < 0.001). Regional compliance of the dependent lung increased significantly with rising PEEP (median PEEP 5 cmH 2 O = 11.9 [IQR 10.4-16.7] ml/cmH 2 O, PEEP 15 cmH 2 O = 19.1 [14.2-21.3] ml/cmH 2 O; p < 0.001), whereas regional compliance of the nondependent lung decreased from PEEP 5 cmH 2 O to PEEP 15 cmH 2 O (PEEP 5 cmH 2 O = 25.3 [21.3-30.4] ml/cmH 2 O, PEEP 15 cmH 2 O = 20

  5. Acoustic ground impedance meter

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.

    1981-01-01

    A compact, portable instrument was developed to measure the acoustic impedance of the ground, or other surfaces, by direct pressure-volume velocity measurement. A Helmholz resonator, constructed of heavy-walled stainless steel but open at the bottom, is positioned over the surface having the unknown impedance. The sound source, a cam-driven piston of known stroke and thus known volume velocity, is located in the neck of the resonator. The cam speed is a variable up to a maximum 3600 rpm. The sound pressure at the test surface is measured by means of a microphone flush-mounted in the wall of the chamber. An optical monitor of the piston displacement permits measurement of the phase angle between the volume velocity and the sound pressure, from which the real and imaginary parts of the impedance can be evaluated. Measurements using a 5-lobed cam can be made up to 300 Hz. Detailed design criteria and results on a soil sample are presented.

  6. Localised electrochemical impedance measurements of a polymer electrolyte fuel cell using a reference electrode array to give cathode-specific measurements and examine membrane hydration dynamics

    NASA Astrophysics Data System (ADS)

    Engebretsen, Erik; Hinds, Gareth; Meyer, Quentin; Mason, Tom; Brightman, Edward; Castanheira, Luis; Shearing, Paul R.; Brett, Daniel J. L.

    2018-04-01

    Advances in bespoke diagnostic techniques for polymer electrolyte fuel cells continue to provide unique insight into the internal operation of these devices and lead to improved performance and durability. Localised measurements of current density have proven to be extremely useful in designing better fuel cells and identifying optimal operating strategies, with electrochemical impedance spectroscopy (EIS) now routinely used to deconvolute the various losses in fuel cells. Combining the two techniques provides another dimension of understanding, but until now each localised EIS has been based on 2-electrode measurements, composed of both the anode and cathode responses. This work shows that a reference electrode array can be used to give individual electrode-specific EIS responses, in this case the cathode is focused on to demonstrate the approach. In addition, membrane hydration dynamics are studied under current load steps from open circuit voltage. A three-stage process is identified associated with an initial rapid reduction in membrane resistance after 10 s of applying a current step, followed by a slower ramp to approximately steady state, which was achieved after ∼250 s. These results support previously published work that has looked at membrane swelling dynamics and reveal that membrane hydration/membrane resistance is highly heterogeneous.

  7. Electromagnetic scattering by impedance structures

    NASA Technical Reports Server (NTRS)

    Balanis, Constantine A.; Griesser, Timothy

    1987-01-01

    The scattering of electromagnetic waves from impedance structures is investigated, and current work on antenna pattern calculation is presented. A general algorithm for determining radiation patterns from antennas mounted near or on polygonal plates is presented. These plates are assumed to be of a material which satisfies the Leontovich (or surface impedance) boundary condition. Calculated patterns including reflection and diffraction terms are presented for numerious geometries, and refinements are included for antennas mounted directly on impedance surfaces. For the case of a monopole mounted on a surface impedance ground plane, computed patterns are compared with experimental measurements. This work in antenna pattern prediction forms the basis of understanding of the complex scattering mechanisms from impedance surfaces. It provides the foundation for the analysis of backscattering patterns which, in general, are more problematic than calculation of antenna patterns. Further proposed study of related topics, including surface waves, corner diffractions, and multiple diffractions, is outlined.

  8. Wavelet-based multiscale analysis of bioimpedance data measured by electric cell-substrate impedance sensing for classification of cancerous and normal cells.

    PubMed

    Das, Debanjan; Shiladitya, Kumar; Biswas, Karabi; Dutta, Pranab Kumar; Parekh, Aditya; Mandal, Mahitosh; Das, Soumen

    2015-12-01

    The paper presents a study to differentiate normal and cancerous cells using label-free bioimpedance signal measured by electric cell-substrate impedance sensing. The real-time-measured bioimpedance data of human breast cancer cells and human epithelial normal cells employs fluctuations of impedance value due to cellular micromotions resulting from dynamic structural rearrangement of membrane protrusions under nonagitated condition. Here, a wavelet-based multiscale quantitative analysis technique has been applied to analyze the fluctuations in bioimpedance. The study demonstrates a method to classify cancerous and normal cells from the signature of their impedance fluctuations. The fluctuations associated with cellular micromotion are quantified in terms of cellular energy, cellular power dissipation, and cellular moments. The cellular energy and power dissipation are found higher for cancerous cells associated with higher micromotions in cancer cells. The initial study suggests that proposed wavelet-based quantitative technique promises to be an effective method to analyze real-time bioimpedance signal for distinguishing cancer and normal cells.

  9. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    NASA Astrophysics Data System (ADS)

    Santos, José; Janeiro, Fernando M.; Ramos, Pedro M.

    2015-10-01

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed.

  10. Reference Centile Curves for Body Fat Percentage, Fat-free Mass, Muscle Mass and Bone Mass Measured by Bioelectrical Impedance in Asian Indian Children and Adolescents.

    PubMed

    Chiplonkar, Shashi; Kajale, Neha; Ekbote, Veena; Mandlik, Rubina; Parthasarathy, Lavanya; Borade, Ashwin; Patel, Pinal; Patel, Prerna; Khadilkar, Vaman; Khadilkar, Anuradha

    2017-12-15

    To create gender-specific percentile curves for percent body fat (%BF) by Bio electrical Impedance Analysis (BIA) for screening adiposity and risk of hypertension in Indian children and generate reference curves for percent fat-free mass (%FFM), muscle mass (%LM) and bone mineral content (BMC) by using bioelectrical impedance. Secondary analysis of data from previous multicenter cross-sectional studies. Private schools from five regions of India. A random sample of 3850 healthy school children (2067 boys) (5-17 yr) from private schools in five major Indian cities. Anthropometry, blood pressure (BP) and body composition were measured by bioelectrical impedance. Reference curves were generated by the LMS method. %BF, %FFM, %LM, BMC and BP. Median %BF increased by 6% from 5 to 13 years of age and declined (around 2%) up to 17 years in boys. In girls, %BF increased by 8% from 5 to 14 years and thereafter declined by 3%. Based upon the risk of hypertension, the new cut-offs of 75th and 85th percentile of %BF were proposed for detecting over fatness and excess fatness in children. Median %FFM was 90% at 5 yrs and decreased till 12 years, and then showed a slight increase to 84% at 17 yrs in boys. In girls, it was 86% at 5 yrs and decreased till 15 yrs, and plateaued at 71.8% at 17 yrs. Reference curves for percent body fat for Indian children would be useful to screen children for health risk in clinical set up.

  11. Impaired bolus clearance in combined high-resolution esophageal manometry and impedance measurement helps to differentiate between esophagogastric junction outflow obstruction and achalasia.

    PubMed

    Zizer, Eugen; Seufferlein, Thomas; Hänle, Mark Martin

    2017-02-01

    Introduction and aims  High-resolution esophageal manometry (HRM) has improved the diagnostic work-up of esophageal motility disorders. Simultaneous evaluation of bolus clearance delivers useful information about the function of tubular esophagus. We assessed bolus clearance in a combined HRM-impedance examination for esophagogastric junction outflow obstruction (EGJOO) in comparison to achalasia patients. The collected data were assessed in a retrospective analysis. Patients and methods  After gastroscopy excluded a mechanical esophageal or gastric obstruction, 142 consecutive patients underwent combined HRM-impedance examination. The assessment and interpretation of the manometry results were done according to the Chicago Classification of esophageal motility disorders v3.0. After classifying the motility disorder, the evaluation of bolus clearance was done according to published studies. Results  All patients with achalasia (n = 24) showed a significantly impaired bolus clearance (< 80 %). Patients with unaffected peristalsis (n = 56) or patients with EGJOO (n = 14) each showed impaired clearance in 7 %, respectively. The evidence of axial hernia was not associated with impaired clearance. Conclusion  Our results demonstrate a significant difference in impedance measurements between EGJOO and achalasia cases. This might be helpful as an additional tool to differentiate between achalasia and EGJOO patients. Furthermore, the role of the combined impedance-HRM investigation for early diagnosis of achalasia in "pre-achalasia" condition or in evaluation of potential progress of EGJOO to achalasia should be evaluated in a prospective study. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Gynecologic electrical impedance tomograph

    NASA Astrophysics Data System (ADS)

    Korjenevsky, A.; Cherepenin, V.; Trokhanova, O.; Tuykin, T.

    2010-04-01

    Electrical impedance tomography extends to the new and new areas of the medical diagnostics: lungs, breast, prostate, etc. The feedback from the doctors who use our breast EIT diagnostic system has induced us to develop the 3D electrical impedance imaging device for diagnostics of the cervix of the uterus - gynecologic impedance tomograph (GIT). The device uses the same measuring approach as the breast imaging system: 2D flat array of the electrodes arranged on the probe with handle is placed against the body. Each of the 32 electrodes of the array is connected in turn to the current source while the rest electrodes acquire the potentials on the surface. The current flows through the electrode of the array and returns through the remote electrode placed on the patient's limb. The voltages are measured relative to another remote electrode. The 3D backprojection along equipotential surfaces is used to reconstruct conductivity distribution up to approximately 1 cm in depth. Small number of electrodes enables us to implement real time imaging with a few frames per sec. rate. The device is under initial testing and evaluation of the imaging capabilities and suitability of usage.

  13. The measurement of peripheral blood volume reactions to tilt test by the electrical impedance technique after exercise in athletes

    NASA Astrophysics Data System (ADS)

    Melnikov, A. A.; Popov, S. G.; Nikolaev, D. V.; Vikulov, A. D.

    2013-04-01

    We have investigated the distribution of peripheral blood volumes in different regions of the body in response to the tilt-test in endurance trained athletes after aerobic exercise. Distribution of peripheral blood volumes (ml/beat) simultaneously in six regions of the body (two legs, two hands, abdomen, neck and ECG) was assessed in response to the tilt-test using the impedance method (the impedance change rate (dZ/dT). Before and after exercise session cardiac stroke (CSV) and blood volumes in legs, arms and neck were higher in athletes both in lying and standing positions. Before exercise the increase of heart rate and the decrease of a neck blood volume in response to tilting was lower (p <0.05) but the decrease of leg blood volumes was higher (p<0.001) in athletes. The reactions in arms and abdomen blood volumes were similar. Also, the neck blood volumes as percentage of CSV (%/CSV) did not change in the control but increased in athletes (p <0.05) in response to the tilt test. After (10 min recovery) the aerobic bicycle exercise (mean HR = 156±8 beat/min, duration 30 min) blood volumes in neck and arms in response to the tilting were reduced equally, but abdomen (p<0.05) and leg blood volumes (p <0.001) were lowered more significantly in athletes. The neck blood flow (%/CSV) did not change in athletes but decreased in control (p<0.01), which was offset by higher tachycardia in response to tilt-test in controls after exercise. The data demonstrate greater orthostatic tolerance in athletes both before and after exercise during fatigue which is due to effective distribution of blood flows aimed at maintaining cerebral blood flow.

  14. Determination of the magnetization scaling exponent for single-crystal La0.8Sr0.2MnO3 by broadband microwave surface impedance measurements

    NASA Astrophysics Data System (ADS)

    Schwartz, Andrew; Scheffler, Marc; Anlage, Steven M.

    2000-01-01

    Employing a broadband microwave reflection configuration, we have measured the complex surface impedance, ZS(ω,T), of single-crystal La0.8Sr0.2MnO3, as a function of frequency (0.045-45 GHz) and temperature (250-325 K). Through the dependence of the microwave surface impedance on the magnetic permeability, μ⁁(ω,T), we have studied the local magnetic behavior of this material, and have extracted the spontaneous magnetization, M0(T), in zero applied field. The broadband nature of these measurements and the fact that no external field is applied to the material provide a unique opportunity to analyze the critical behavior of the spontaneous magnetization at temperatures very close to the ferromagnetic phase transition. We find a Curie temperature TC=305.5+/-0.5 K and scaling exponent β=0.45+/-0.05, in agreement with the prediction of mean-field theory. We also discuss other recent determinations of the magnetization critical exponent in this and similar materials and show why our results are more definitive.

  15. A Time Domain Impedance Probe For Ultra-Fast Measurements of Electron Parameters in the Ionosphere: Results From A NASA USIP Experiment

    NASA Astrophysics Data System (ADS)

    Clark, D. C.; Spencer, E. A.; Gollapalli, R.; Kerrigan, B.

    2016-12-01

    A plasma impedance probe is used to obtain plasma parameters in the ionosphere by measuring the magnitude, shape and location of resonances in the frequency spectrum when a probe structure is driven with RF excitation. We have designed and developed a new Time Domain Impedance Probe (TDIP) capable of making measurements of absolute electron density and electron neutral collision frequency at temporal and spatial resolutions not previously attained. A single measurement can be made in a time as short as 100 microseconds, which yields much higher spatial resolution than a frequency sweep method. This method essentially consists of applying a small amplitude time limited voltage signal into a probe and measuring the resulting current response. The frequency bandwidth of the voltage signal is selected in order that the electron plasma resonances are observable. A prototype of the new instrument was flown at 08:45 EST on March 1 2016 on a NASA Undergraduate Student Instrument Progam (USIP) sounding rocket launched out of Wallops Flight Facility (Flight time was around 20 minutes). Here we analyze the data from the sounding rocket experiment, using an adaptive system identification technique to compare the measured data with analytical formulas obtained from a theoretical consideration of the time domain response. The analytical formula is calibrated to a plasma fluid finite difference time domain (PFFDTD) numerical computation before using it to analyze the rocket data from 85 km to 170 km on both upleg and downleg. Our results show that the technique works as advertised, but several issues including payload charging and signal rectification remains to be resolved. A plasma impedance probe is used to obtain plasma parameters in the ionosphere by measuring the magnitude, shape and location of resonances in the frequency spectrum when a probe structure is driven with RF excitation. We have designed and developed a new Time Domain Impedance Probe (TDIP) capable of making

  16. A Method for the Measurement of Acoustic Impedance and Speed of Sound in a Small Region of Bone using a Fused Quartz Rod as a Transmission Line

    NASA Astrophysics Data System (ADS)

    Hatakeyama, Rokuro; Yoshizawa, Masazumi; Moriya, Tadashi

    2000-11-01

    Precise correction for γ-ray attenuation in skull bone has been a significant problem in obtaining quantitative single photon emission computed tomography (SPECT) images. The correction for γ-ray attenuation is approximately proportional to the density and thickness of the bone under investigation. If the acoustic impedance and the speed of sound in bone are measurable using ultrasonic techniques, then the density and thickness of the bone sample can be calculated. Whole bone usually consists of three layers, and each layer has a different ultrasonic character. Thus, the speed of sound must be measured in a small section of each layer in order to determine the overall density of whole bone. It is important to measure the attenuation constant in order to determine the appropriate level for the ultrasonic input signal. We have developed a method for measuring the acoustic impedance, speed of sound, and attenuation constant in a small region of a bone sample using a fused quartz rod as a transmission line. In the present study, we obtained the following results: impedance of compact bone; 5.30(±0.40)× 106 kg/(m2s), speed of sound; 3780± 250 m/s, and attenuation constant; 2.70± 0.50 Np/m. These results were used to obtain the densities of compact bone, spongy bone and bone marrow in a bovine bone sample and as well as the density of pig skull bone, which were found to be 1.40± 0.30 g/cm3, 1.19± 0.50 g/cm3, 0.90± 0.30 g/cm3 and 1.26± 0.30 g/cm3, respectively. Using a thin solid transmission line, the proposed method makes it possible to determine the density of a small region of a bone sample. It is expected that the proposed method, which is based on ultrasonic measurement, will be useful for application in brain SPECT.

  17. Outdoor ground impedance models.

    PubMed

    Attenborough, Keith; Bashir, Imran; Taherzadeh, Shahram

    2011-05-01

    Many models for the acoustical properties of rigid-porous media require knowledge of parameter values that are not available for outdoor ground surfaces. The relationship used between tortuosity and porosity for stacked spheres results in five characteristic impedance models that require not more than two adjustable parameters. These models and hard-backed-layer versions are considered further through numerical fitting of 42 short range level difference spectra measured over various ground surfaces. For all but eight sites, slit-pore, phenomenological and variable porosity models yield lower fitting errors than those given by the widely used one-parameter semi-empirical model. Data for 12 of 26 grassland sites and for three beech wood sites are fitted better by hard-backed-layer models. Parameter values obtained by fitting slit-pore and phenomenological models to data for relatively low flow resistivity grounds, such as forest floors, porous asphalt, and gravel, are consistent with values that have been obtained non-acoustically. Three impedance models yield reasonable fits to a narrow band excess attenuation spectrum measured at short range over railway ballast but, if extended reaction is taken into account, the hard-backed-layer version of the slit-pore model gives the most reasonable parameter values.

  18. Electric cell-substrate impedance sensing (ECIS) based real-time measurement of titer dependent cytotoxicity induced by adenoviral vectors in an IPI-2I cell culture model.

    PubMed

    Müller, Jakob; Thirion, Christian; Pfaffl, Michael W

    2011-01-15

    Recombinant viral vectors are widespread tools for transfer of genetic material in various modern biotechnological applications like for example RNA interference (RNAi). However, an accurate and reproducible titer assignment represents the basic step for most downstream applications regarding a precise multiplicity of infection (MOI) adjustment. As necessary scaffold for the studies described in this work we introduce a quantitative real-time PCR (qPCR) based approach for viral particle measurement. Still an implicated problem concerning physiological effects is that the appliance of viral vectors is often attended by toxic effects on the individual target. To determine the critical viral dose leading to cell death we developed an electric cell-substrate impedance sensing (ECIS) based assay. With ECIS technology the impedance change of a current flow through the cell culture medium in an array plate is measured in a non-invasive manner, visualizing effects like cell attachment, cell-cell contacts or proliferation. Here we describe the potential of this online measurement technique in an in vitro model using the porcine ileal epithelial cell line IPI-2I in combination with an adenoviral transfection vector (Ad5-derivate). This approach shows a clear dose-depending toxic effect, as the amount of applied virus highly correlates (p<0.001) with the level of cell death. Thus this assay offers the possibility to discriminate the minimal non-toxic dose of the individual transfection method. In addition this work suggests that the ECIS-device bears the feasibility to transfer this assay to multiple other cytotoxicological questions. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. A flexible electrode array for muscle impedance measurements in the mouse hind limb: A tool to speed research in neuromuscular disease

    NASA Astrophysics Data System (ADS)

    Li, J.; Rutkove, S. B.

    2013-04-01

    Electrical impedance myography (EIM) is a bioelectrical impedance technique focused on the assessment of neuromuscular diseases using tetrapolar surface arrays. Recently, we have shown that reproducible and sensitive EIM measurements can be made on the gastrocnemius muscle of the mouse hind limb and that these are sensitive to disease alterations. A dedicated array would help speed data acquisition and provide additional sensitivity to disease-induced alterations. A flexible electrode array was developed with electrode sizes of 1mm × 1mm by Parlex, Inc. Tetrapolar electrode sets were arranged both parallel to (longitudinal) and orthogonally to (transverse) the major muscle fiber direction of the gastrocnemius muscle. Measurements were made with a dedicated EIM system. A total of 11 healthy animals and 7 animals with spinal muscular atrophy (a form of motor neuron disease) were evaluated after the fur was completely removed with a depilatory agent from the hind limb. Standard electrophysiologic testing (compound motor action potential amplitude and motor unit number estimation) was also performed. The flexible electrode array demonstrated high repeatability in both the longitudinal and transverse directions in the healthy and diseased animals (with intraclass correlation coefficients of 0.94 and 0.89, respectively, for phase angle measured transversely). In addition, differences between healthy and diseased animals were identifiable. For example, the 50 kHz transverse phase angle was higher in the healthy as compared to the SMA animals (16.8° ± 0.5 vs. 14.3° ± 0.7, respectively) at 21 weeks of age (p = 0.01). Differences in anisotropy were also identifiable. Correlations to several standard neurophysiologic parameters also appeared promising. This novel flexible tetrapolar electrode array can be used on the mouse hind limb and provides multidirectional data that can be used to assess muscle health. This technique has the potential of finding widespread use in

  20. Comparative study of structural, optical and impedance measurements on V{sub 2}O{sub 5} and V-Ce mixed oxide thin films

    SciTech Connect

    Malini, D. Rachel; Sanjeeviraja, C., E-mail: sanjeeviraja@rediffmail.com

    Vanadium pentoxide (V{sub 2}O{sub 5}) and Vanadium-Cerium mixed oxide thin films at different molar ratios of V{sub 2}O{sub 5} and CeO{sub 2} have been deposited at 200 W rf power by rf planar magnetron sputtering in pure argon atmosphere. The structural and optical properties were studied by taking X-ray diffraction and transmittance and absorption spectra respectively. The amorphous thin films show an increase in transmittance and optical bandgap with increase in CeO{sub 2} content in as-prepared thin films. The impedance measurements for as-deposited thin films show an increase in electrical conductivity with increase in CeO{sub 2} material.

  1. Comparative associations between anthropometric and bioelectric impedance analysis derived adiposity measures with blood pressure and hypertension in India: a cross-sectional analysis.

    PubMed

    Taing, Kevin Y; Farkouh, Michael E; Moineddin, Rahim; Tu, Jack V; Jha, Prabhat

    2017-01-01

    The utility of bioelectrical impedance analysis (BIA) derived adiposity measures as compared to anthropometric measures for the assessment of adiposity-related health risk is not clear. We aimed to clarify the relationships of BIA and anthropometric derived adipose measures with blood pressure and hypertension, and to compare the discriminative ability of the respective measures for hypertension. We used baseline data collected between 2015 and 2016 from the Indian Study on Health of Adults (ISHA), an ongoing population based cohort study in India ( N  = 5990; age 30-69 years). We examined and compared the associations and discriminative ability between anthropometric (body mass index, waist circumference, hip circumference, waist-hip ratio, waist-height ratio) and BIA (whole body and trunk fat percentage) derived adiposity measures with blood pressure components (systolic pressure, diastolic pressure, pulse pressure, mean arterial pressure, mid-blood pressure) and hypertension. Regardless of whether the adiposity measure was derived from BIA or anthropometry, all were strongly and positively associated with blood pressure and hypertension. For both men and women, the magnitude of association of BIA measures with blood pressure and hypertension were comparable to those of anthropometric measures. Further, the ability of BIA derived adiposity measures to distinguish between those with and without hypertension was similar to the discriminative ability of anthropometric measures. As compared to simple anthropometric measures, BIA derived estimates of adiposity provide no apparent advantage in the assessment of blood pressure and hypertension. The observed similarities between adiposity measures suggest that simple anthropometrics may be sufficient to assess adiposity and adiposity-related risks.

  2. NOTE: Impedance magnetocardiogram

    NASA Astrophysics Data System (ADS)

    Kandori, Akihiko; Miyashita, Tsuyoshi; Suzuki, Daisuke; Yokosawa, Koichi; Tsukada, Keiji

    2001-02-01

    We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart - the so-called magnetocardiogram (MCG) - can be simultaneously detected by using this system. Because the mechanical and electrical functions in the heart can be monitored by non-invasive and non-contact measurements, it is easy to observe the cardiovascular functions from an accurate sensor position. This system uses a technique to demodulate induced current in a subject. A flux-locked circuit of a superconducting quantum interference device has a wide frequency range (above 1 MHz) because a constant current (40 kHz) is fed through the subject. It is shown for the first time that the system could measure IMCG signals at the same time as MCG signals.

  3. Home environmental consequences of commute travel impedance.

    PubMed

    Novaco, R W; Kliewer, W; Broquet, A

    1991-12-01

    The physical and perceptual dimensions of commuting travel impedance were again found to have stressful consequences in a study of 99 employees of two companies. This quasi-experimental replication study, which focuses here on home environment consequences, investigated the effects of physical impedance and subjective impedance on multivariate measures of residential satisfaction and personal affect in the home. Both sets of residential outcome measures were significantly related to the two impedance dimensions. As predicted, gender was a significant moderator of physical impedance effects. Women commuting on high physical impedance routes were most negatively affected. Previously found subjective impedance effects on negative home mood, regardless of gender, were strongly replicated with several methods and were buttressed by convergent results with objective indices. The theoretical conjecture that subjective impedance mediates the stress effects of physical impedance was supported by the personal affect cluster but only for one variable in the residential satisfaction cluster. Traffic congestion has increased in metropolitan areas nationwide, and commuters, families, and organizations are absorbing associated hidden costs. The results are reviewed in terms of our ecological model, and the moderating effects of gender are discussed in terms of choice and role constraints.

  4. Oxygen surface exchange kinetics measurement by simultaneous optical transmission relaxation and impedance spectroscopy: Sr(Ti,Fe)O3-x thin film case study.

    PubMed

    Perry, Nicola H; Kim, Jae Jin; Tuller, Harry L

    2018-01-01

    We compare approaches to measure oxygen surface exchange kinetics, by simultaneous optical transmission relaxation (OTR) and AC-impedance spectroscopy (AC-IS), on the same mixed conducting SrTi 0.65 Fe 0.35 O 3-x film. Surface exchange coefficients were evaluated as a function of oxygen activity in the film, controlled by gas partial pressure and/or DC bias applied across the ionically conducting yttria-stabilized zirconia substrate. Changes in measured light transmission through the film over time (relaxations) resulted from optical absorption changes in the film corresponding to changes in its oxygen and oxidized Fe (~Fe 4+ ) concentrations; such relaxation profiles were successfully described by the equation for surface exchange-limited kinetics appropriate for the film geometry. The k chem values obtained by OTR were significantly lower than the AC-IS derived k chem values and k q values multiplied by the thermodynamic factor (bulk or thin film), suggesting a possible enhancement in k by the metal current collectors (Pt, Au). Long-term degradation in k chem and k q values obtained by AC-IS was also attributed to deterioration of the porous Pt current collector, while no significant degradation was observed in the optically derived k chem values. The results suggest that, while the current collector might influence measurements by AC-IS, the OTR method offers a continuous, in situ , and contact-free method to measure oxygen exchange kinetics at the native surfaces of thin films.

  5. Oxygen surface exchange kinetics measurement by simultaneous optical transmission relaxation and impedance spectroscopy: Sr(Ti,Fe)O3-x thin film case study

    PubMed Central

    Perry, Nicola H.; Kim, Jae Jin; Tuller, Harry L.

    2018-01-01

    Abstract We compare approaches to measure oxygen surface exchange kinetics, by simultaneous optical transmission relaxation (OTR) and AC-impedance spectroscopy (AC-IS), on the same mixed conducting SrTi0.65Fe0.35O3-x film. Surface exchange coefficients were evaluated as a function of oxygen activity in the film, controlled by gas partial pressure and/or DC bias applied across the ionically conducting yttria-stabilized zirconia substrate. Changes in measured light transmission through the film over time (relaxations) resulted from optical absorption changes in the film corresponding to changes in its oxygen and oxidized Fe (~Fe4+) concentrations; such relaxation profiles were successfully described by the equation for surface exchange-limited kinetics appropriate for the film geometry. The kchem values obtained by OTR were significantly lower than the AC-IS derived kchem values and kq values multiplied by the thermodynamic factor (bulk or thin film), suggesting a possible enhancement in k by the metal current collectors (Pt, Au). Long-term degradation in kchem and kq values obtained by AC-IS was also attributed to deterioration of the porous Pt current collector, while no significant degradation was observed in the optically derived kchem values. The results suggest that, while the current collector might influence measurements by AC-IS, the OTR method offers a continuous, in situ, and contact-free method to measure oxygen exchange kinetics at the native surfaces of thin films. PMID:29511391

  6. Integrated ZnO nanoparticles on paper-based microfluidic: toward efficient analytical device for glucose detection based on impedance and FTIR measurement

    NASA Astrophysics Data System (ADS)

    Yuwono, Rio Akbar; Izdiharruddin, Mokhammad Fahmi; Wahyuono, Ruri Agung

    2016-11-01

    Microfluidic paper-based analytical devices decorated with ZnO nanospherical (nanoSPs) aggregates (ZnO-μPAD) for glucose detection have been fabricated. ZnO nanoSPs were prepared by wet chemical synthesis and integrated on the optimized geometry of ZnO-μPAD has 0.2 and 0.4 mm of channel width and length, respectively. Glucose detection measurements were based on electrochemical and infrared transmission measurements. The glucose concentrations were adjusted as 5, 6.5, and 9 mmol, i.e. typical glucose level for normal, pre-diabetes and diabetes, in a mixture of ringer lactate as simulated biological fluid and red blood cells. ZnO nanoSPs in this study possess an average aggregate size of 160 nm formed by clustered 18 nm crystallite size and ordered porous matrix as well as a surface area of 15 m2·g-1.The separation process of the glucose sample on ZnO-μPAD requires approximately 45 s. The glucose detection results show that both electrochemical-based and FTIR-based measurements perform a linear measurement system (R2 of 0.81 to 0.99) with a relatively high sensitivity. A linearly decreasing impedance spanning from 2.2 - 0.6 Ohm and linearly increasing ΔIR transmission spanning from 3 - 19% are obtained for glucose level ranging from 5 - 9 mmol.

  7. Experimental study of two-phase fluid flow in two different porosity types of sandstone by P-wave velocity and electrical Impedance measurement

    NASA Astrophysics Data System (ADS)

    Honda, H.; Mitani, Y.; Kitamura, K.; Ikemi, H.; Takaki, S.

    2015-12-01

    Carbon dioxide (CO2) capture and storage (CCS) is recently expected as the promising method to reduce greenhouse gas emissions. It is important to investigate CO2 behavior in the reservoir, to evaluate the safety and to account the stored CO2 volume. In this study, experimental investigation is conducted to discuss the relationships between injected fluid speed (Flow rate: FR) or capillary number (Ca) and non-wetting fluid flow by compressional wave velocity (Vp) and electrical impedance (Z). In the experiment, N2 and supercritical CO2 were injected into the two sandstones with different porosity (φ), Berea sandstone (φ: 18 %), and Ainoura sandstone (φ: 11.9 %). The dimension of the rock specimens is cored cylinder with a 35 mm diameter and 70 mm height. Experimental conditions are nearly same as the reservoir of deep underground (Confining pressure:15MPa, 40℃). Initial conditions of the specimen are brine (0.1wt%-KCl) saturated. Four piezo-electrical transducers (PZTs) are set on the each surface of the top, middle, lower of the specimen to monitor the CO2 bahavior by Vp. To measuring Z, we use for electrodes method with Ag-AgCl electrodes. Four electrodes are wounded around specimen on the both sides of PZTs. We measured the changes of these parameters with injecting N2, injected fluid speed (FR), the differential pore pressure (DP), N2 saturation (SN2), P-wave velocity (Vp) and electrical impedance (Z), respectively. We also estimated the Ca from measured FR. From these experimental results, there are no obvious Vp changes with increasing Ca, while Z measurement indicates clear and continuous increment. In regards to Vp, Vp reduced at the small FR (0.1 to 0.2 ml/min). As the Ca increases, Vp doesn't indicate large reduction. On the other hand, Z is more sensitive to change the fluid saturation than Vp. It is well-known that both of Vp and Z are the function of fluid saturation. Though, these experimental results are not consistent with previous studies. In

  8. The in-line measurement of plant cell biomass using radio frequency impedance spectroscopy as a component of process analytical technology.

    PubMed

    Holland, Tanja; Blessing, Daniel; Hellwig, Stephan; Sack, Markus

    2013-10-01

    Radio frequency impedance spectroscopy (RFIS) is a robust method for the determination of cell biomass during fermentation. RFIS allows non-invasive in-line monitoring of the passive electrical properties of cells in suspension and can distinguish between living and dead cells based on their distinct behavior in an applied radio frequency field. We used continuous in situ RFIS to monitor batch-cultivated plant suspension cell cultures in stirred-tank bioreactors and compared the in-line data to conventional off-line measurements. RFIS-based analysis was more rapid and more accurate than conventional biomass determination, and was sensitive to changes in cell viability. The higher resolution of the in-line measurement revealed subtle changes in cell growth which were not accessible using conventional methods. Thus, RFIS is well suited for correlating such changes with intracellular states and product accumulation, providing unique opportunities for employing systems biotechnology and process analytical technology approaches to increase product yield and quality. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Evaluation of NK cell function by flowcytometric measurement and impedance based assay using real-time cell electronic sensing system.

    PubMed

    Park, Ki-Hyun; Park, Hyesun; Kim, Myungshin; Kim, Yonggoo; Han, Kyungja; Oh, Eun-Jee

    2013-01-01

    Although real-time cell electronic sensing (RT-CES) system-based natural killer (NK) cytotoxicity has been introduced, it has not been evaluated using human blood samples. In present study, we measured flowcytometry based assay (FCA) and RT-CES based NK cytotoxicity and analyzed degranulation activity (CD107a) and cytokine production. In 98 healthy individuals, FCA with peripheral blood mononuclear cells (PBMCs) at effector to target (E/T) ratio of 32 revealed 46.5 ± 2.6% cytolysis of K562 cells, and 23.5 ± 1.1% of NK cells showed increased degranulation. In RT-CES system, adherent NIH3T3 target cells were resistant to basal killing by PBMC or NK cells. NK cell activation by adding IL-2 demonstrated real-time dynamic killing activity, and lymphokine-activated PBMC (E/T ratio of 32) from 15 individuals showed 59.1 ± 6.2% cytotoxicity results after 4 hours incubation in RT-CES system. However, there was no significant correlation between FCA and RT-CES cytotoxicity. After K562 target cell stimulation, PBMC produced profound proinflammatory and immunoregulatory cytokines/chemokines including IL-2, IL-8, IL-10, MIP-1 α β , IFN- γ , and TNF- α , and cytokine/chemokine secretion was related to flowcytometry-based NK cytotoxicity. These data suggest that RT-CES and FCA differ in sensitivity, applicability and providing information, and further investigations are necessary in variable clinical conditions.

  10. Impedance of a nanoantenna

    SciTech Connect

    Greffet, Jean-Jacques; Laroche, Marine; Marquier, Francois

    2009-10-07

    We introduce a generalized definition of the impedance of a nanoantenna that can be applied to any system. We also introduce a definition of the impedance of a two level system. Using this framework, we establish a link between the electrical engineering and the quantum optics picture of light emission.

  11. Evaluation of NK Cell Function by Flowcytometric Measurement and Impedance Based Assay Using Real-Time Cell Electronic Sensing System

    PubMed Central

    Park, Ki-Hyun; Park, Hyesun; Kim, Myungshin; Kim, Yonggoo; Han, Kyungja; Oh, Eun-Jee

    2013-01-01

    Although real-time cell electronic sensing (RT-CES) system-based natural killer (NK) cytotoxicity has been introduced, it has not been evaluated using human blood samples. In present study, we measured flowcytometry based assay (FCA) and RT-CES based NK cytotoxicity and analyzed degranulation activity (CD107a) and cytokine production. In 98 healthy individuals, FCA with peripheral blood mononuclear cells (PBMCs) at effector to target (E/T) ratio of 32 revealed 46.5 ± 2.6% cytolysis of K562 cells, and 23.5 ± 1.1% of NK cells showed increased degranulation. In RT-CES system, adherent NIH3T3 target cells were resistant to basal killing by PBMC or NK cells. NK cell activation by adding IL-2 demonstrated real-time dynamic killing activity, and lymphokine-activated PBMC (E/T ratio of 32) from 15 individuals showed 59.1 ± 6.2% cytotoxicity results after 4 hours incubation in RT-CES system. However, there was no significant correlation between FCA and RT-CES cytotoxicity. After K562 target cell stimulation, PBMC produced profound proinflammatory and immunoregulatory cytokines/chemokines including IL-2, IL-8, IL-10, MIP-1α β, IFN-γ, and TNF-α, and cytokine/chemokine secretion was related to flowcytometry-based NK cytotoxicity. These data suggest that RT-CES and FCA differ in sensitivity, applicability and providing information, and further investigations are necessary in variable clinical conditions. PMID:24236291

  12. An improved water-filled impedance tube.

    PubMed

    Wilson, Preston S; Roy, Ronald A; Carey, William M

    2003-06-01

    A water-filled impedance tube capable of improved measurement accuracy and precision is reported. The measurement instrument employs a variation of the standardized two-sensor transfer function technique. Performance improvements were achieved through minimization of elastic waveguide effects and through the use of sound-hard wall-mounted acoustic pressure sensors. Acoustic propagation inside the water-filled impedance tube was found to be well described by a plane wave model, which is a necessary condition for the technique. Measurements of the impedance of a pressure-release terminated transmission line, and the reflection coefficient from a water/air interface, were used to verify the system.

  13. Network analysis of semiconducting Zn1-xCdxS based photosensitive device using impedance spectroscopy and current-voltage measurement

    NASA Astrophysics Data System (ADS)

    Datta, Joydeep; Das, Mrinmay; Dey, Arka; Halder, Soumi; Sil, Sayantan; Ray, Partha Pratim

    2017-10-01

    ZnCdS is an intermediate ternary alloy type semiconducting material which has huge tunable structural, optical and electrical properties. Here, we have synthesized Zn1-xCdxS compound and characterized its structural, optical and charge transport properties. It is seen that the particle size is greatly influenced by the amount of alloy concentration of cadmium. The performance of semiconductor device such as Schottky diode depends mainly on the charge transportation through the metal-semiconductor junction. So, we have fabricated Al/Zn1-xCdxS/ITO device and investigated the bias dependent impedance properties through equivalent circuit network analysis to study the electron lifetime and interfacial region resistance. The result of network analysis indicates that the charge transportation through Al- Zn0.6Cd0.4S is better than the other fabricated devices. For further explanation, we have studied the capacitance-voltage (C-V) characteristic under dark and current-voltage (I-V) characteristic under dark and light. We have investigated barrier height, depletion layer width and employed SCLC (space charge limited current) theory in I-V characteristics to determine mobility, transit time and diffusion length. The mobility and diffusion length for Zn0.6Cd0.4S fabricated device are derived as 23.01 m2 V-1 s-1 and 4.4 μm respectively while both the values are less for the other devices. These values are enhanced upon illumination for all the devices but superiority comes from the Al/Zn0.6Cd0.4S/ITO device and it leads us to measure the photosensitivity, responsivity, specific detectivity. As expected, the photosensing parameters are enhanced for the Zn0.6Cd0.4S fabricated device. So, this literature not only explores the metal semiconductor charge transportation using impedance spectroscopy (IS) network analysis and SCLC theory but also explain it from the structural point of view.

  14. Body composition of adult cystic fibrosis patients and control subjects as determined by densitometry, bioelectrical impedance, total-body electrical conductivity, skinfold measurements, and deuterium oxide dilution

    SciTech Connect

    Newby, M.J.; Keim, N.L.; Brown, D.L.

    1990-08-01

    This study contrasts body compositions (by six methods) of eight cystic fibrosis (CF) subjects with those of eight control subjects matched for age, height, and sex. CF subjects weighed 84% as much as control subjects. Densitometry and two bioelectrical impedance-analysis methods suggested that reduced CF weights were due to less lean tissue (10.7, 9.5, and 10.4 kg). Total-body electrical conductivity (TOBEC) and skinfold-thickness measurements indicated that CF subjects were leaner than control subjects and had less fat (5.4 and 3.6 kg) and less lean (5.2 and 7 kg) tissue. D2O dilution showed a pattern similar to TOBEC (8.3 kg lessmore » lean, 2.7 kg less fat tissue). Densitometry estimates of fat (mass and percent) were not correlated (r less than 0.74, p greater than 0.05) with any other method for CF subjects but were correlated with all other methods for control subjects. CF subjects contained less fat and lean tissue than did control subjects. Densitometry by underwater weighing is unsuitable for assessing body composition of CF patients.« less

  15. Lung disease severity in idiopathic pulmonary fibrosis is more strongly associated with impedance measures of bolus reflux than pH parameters of acid reflux alone.

    PubMed

    Gavini, S; Borges, L F; Finn, R T; Lo, W-K; Goldberg, H J; Burakoff, R; Feldman, N; Chan, W W

    2017-05-01

    Gastroesophageal reflux (GER) has been associated with idiopathic pulmonary fibrosis (IPF). Pathogenesis may be related to chronic micro-aspiration. We aimed to assess objective measures of GER on multichannel intraluminal impedance and pH study (MII-pH) and their relationship with pulmonary function testing (PFT) results, and to compare the performance of pH/acid reflux parameters vs corresponding MII/bolus parameters in predicting pulmonary dysfunction in IPF. This was a retrospective cohort study of IPF patients undergoing prelung transplant evaluation with MII-pH off acid suppression, and having received PFT within 3 months. Patients with prior fundoplication were excluded. Severe pulmonary dysfunction was defined using diffusion capacity of the lung for carbon monoxide (DLCO) ≤40%. Six pH/acid reflux parameters with corresponding MII/bolus reflux measures were specified a priori. Multivariate analyses were applied using forward stepwise logistic regression. Predictive value of each parameter for severe pulmonary dysfunction was calculated by area-under-the-receiver-operating-characteristic-curve or c-statistic. Forty-five subjects (67% M, age 59, 15 mild-moderate vs 30 severe) met criteria for inclusion. Patient demographics and clinical characteristics were similar between pulmonary dysfunction groups. Abnormal total reflux episodes and prolonged bolus clearance time were significantly associated with pulmonary dysfunction severity on univariate and multivariate analyses. No pH parameters were significant. The c-statistic of each pH parameter was lower than its MII counterpart in predicting pulmonary dysfunction. MII/bolus reflux, but not pH/acid reflux, was associated with pulmonary dysfunction in prelung transplant patients with IPF. MII-pH may be more valuable than pH testing alone in characterizing GER in IPF. © 2016 John Wiley & Sons Ltd.

  16. Pre-lung transplant measures of reflux on impedance are superior to pH testing alone in predicting early allograft injury

    PubMed Central

    Lo, Wai-Kit; Burakoff, Robert; Goldberg, Hilary J; Feldman, Natan; Chan, Walter W

    2015-01-01

    AIM: To evaluate pre-lung transplant acid reflux on pH-testing vs corresponding bolus reflux on multichannel intraluminal impedance (MII) to predict early allograft injury. METHODS: This was a retrospective cohort study of lung transplant recipients who underwent pre-transplant combined MII-pH-testing at a tertiary care center from January 2007 to November 2012. Patients with pre-transplant fundoplication were excluded. Time-to-event analysis was performed using a Cox proportional hazards model to assess associations between measures of reflux on MII-pH testing and early allograft injury. Area under the receiver operating characteristic (ROC) curve (c-statistic) of the Cox model was calculated to assess the predictive value of each reflux parameter for early allograft injury. Six pH-testing parameters and their corresponding MII measures were specified a priori. The pH parameters were upright, recumbent, and overall acid reflux exposure; elevated acid reflux exposure; total acid reflux episodes; and acid clearance time. The corresponding MII measures were upright, recumbent, and overall bolus reflux exposure; elevated bolus reflux exposure; total bolus reflux episodes; and bolus clearance time. RESULTS: Thirty-two subjects (47% men, mean age: 55 years old) met the inclusion criteria of the study. Idiopathic pulmonary fibrosis (46.9%) represented the most common pulmonary diagnosis leading to transplantation. Baseline demographics, pre-transplant cardiopulmonary function, number of lungs transplanted (unilateral vs bilateral), and post-transplant proton pump inhibitor use were similar between reflux severity groups. The area under the ROC curve, or c-statistic, of each acid reflux parameter on pre-transplant pH-testing was lower than its bolus reflux counterpart on MII in the prediction of early allograft injury. In addition, the development of early allograft injury was significantly associated with three pre-transplant MII measures of bolus reflux: overall reflux

  17. Fast measurement of proton exchange membrane fuel cell impedance based on pseudo-random binary sequence perturbation signals and continuous wavelet transform

    NASA Astrophysics Data System (ADS)

    Debenjak, Andrej; Boškoski, Pavle; Musizza, Bojan; Petrovčič, Janko; Juričić, Đani

    2014-05-01

    This paper proposes an approach to the estimation of PEM fuel cell impedance by utilizing pseudo-random binary sequence as a perturbation signal and continuous wavelet transform with Morlet mother wavelet. With the approach, the impedance characteristic in the frequency band from 0.1 Hz to 500 Hz is identified in 60 seconds, approximately five times faster compared to the conventional single-sine approach. The proposed approach was experimentally evaluated on a single PEM fuel cell of a larger fuel cell stack. The quality of the results remains at the same level compared to the single-sine approach.

  18. In vivo imaging of twist drill drainage for subdural hematoma: a clinical feasibility study on electrical impedance tomography for measuring intracranial bleeding in humans.

    PubMed

    Dai, Meng; Li, Bing; Hu, Shijie; Xu, Canhua; Yang, Bin; Li, Jianbo; Fu, Feng; Fei, Zhou; Dong, Xiuzhen

    2013-01-01

    Intracranial bleeding is one of the most severe medical emergencies in neurosurgery. Early detection or diagnosis would largely reduce the rate of disability and mortality, and improve the prognosis of the patients. Electrical Impedance Tomography (EIT) can non-invasively image the internal resistivity distribution within a human body using a ring of external electrodes, and is thus a promising technique to promptly detect the occurrence of intracranial bleedings because blood differs from other brain tissues in resistivity. However, so far there is no experimental study that has determined whether the intracranial resistivity changes in humans could be repeatedly detected and imaged by EIT. Hence, we for the first time attempt to clinically validate this by in vivo imaging the influx and efflux of irrigating fluid (5% dextrose in water, D5W) during the twist-drill drainage operation for the patients with subdural hematoma (SDH). In this study, six patients (four male, two female) with subacute or chronic SDH received the surgical operation in order to evacuate the hematoma around subdural region, and EIT measurements were performed simultaneously on each patient's head. The results showed that the resistivity significantly increased on the corresponding position of EIT images during the influx of D5W and gradually decreased back to baseline during the efflux. In the quantitative analysis, the average resistivity values demonstrated the similar results and had highly linear correlation (R(2) = 0.93 ± 0.06) with the injected D5W volumes, as well as the area of the resistivity gain(R(2) = 0.94 ± 0.05). In conclusion, it was clinically validated that intracranial resistivity changes in humans were detectable and quantifiable by the EIT method. After further technical improvements, EIT has the great potential of being a routine neuroimaging tool for early detection of intracranial bleedings.

  19. In Vivo Imaging of Twist Drill Drainage for Subdural Hematoma: A Clinical Feasibility Study on Electrical Impedance Tomography for Measuring Intracranial Bleeding in Humans

    PubMed Central

    Xu, Canhua; Yang, Bin; Li, Jianbo; Fu, Feng; Fei, Zhou; Dong, Xiuzhen

    2013-01-01

    Intracranial bleeding is one of the most severe medical emergencies in neurosurgery. Early detection or diagnosis would largely reduce the rate of disability and mortality, and improve the prognosis of the patients. Electrical Impedance Tomography (EIT) can non-invasively image the internal resistivity distribution within a human body using a ring of external electrodes, and is thus a promising technique to promptly detect the occurrence of intracranial bleedings because blood differs from other brain tissues in resistivity. However, so far there is no experimental study that has determined whether the intracranial resistivity changes in humans could be repeatedly detected and imaged by EIT. Hence, we for the first time attempt to clinically validate this by in vivo imaging the influx and efflux of irrigating fluid (5% dextrose in water, D5W) during the twist-drill drainage operation for the patients with subdural hematoma (SDH). In this study, six patients (four male, two female) with subacute or chronic SDH received the surgical operation in order to evacuate the hematoma around subdural region, and EIT measurements were performed simultaneously on each patient’s head. The results showed that the resistivity significantly increased on the corresponding position of EIT images during the influx of D5W and gradually decreased back to baseline during the efflux. In the quantitative analysis, the average resistivity values demonstrated the similar results and had highly linear correlation (R2 = 0.93±0.06) with the injected D5W volumes, as well as the area of the resistivity gain(R2 = 0.94±0.05). In conclusion, it was clinically validated that intracranial resistivity changes in humans were detectable and quantifiable by the EIT method. After further technical improvements, EIT has the great potential of being a routine neuroimaging tool for early detection of intracranial bleedings. PMID:23372808

  20. Validation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obese Colombian adults.

    PubMed

    Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; González-Jiménez, Emilio; Triana-Reina, Hector Reynaldo; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline

    2018-01-01

    To verify the validity of multi-frequency bioelectrical impedance analysis (mBCA) for predicting body fat percentage (BF%) in overweight/obese adults using dual-energy X-ray absorptiometry (DXA) as the reference method. Forty-eight adults participated (54% women, mean age = 41.0 ± 7.3 years old). The Pearson's correlation coefficient was used to evaluate the correlation between BIA and BF% assessed by DXA. The concordance between BF% measured by both methods was obtained with Lin's concordance correlation coefficient and Bland-Altman difference plots. Measures of BF% were estimated as 39.0 (SD = 6.1) and 38.3 (SD = 6.5) using DXA and mBCA, respectively. The Pearson's correlation coefficient reflected a strong correlation (r =.921, P = .001). The paired t-test showed a significant mean difference between these methods for obese men BF% of -0.6 [(SD 1.95; 95% CI = -4.0 to 3.0), P =.037]. Overall, the bias of the mBCA was -0.6 [(SD 2.2; 95% CI = -5.0 to 3.7), P =.041], which indicated that the mBCA method significantly underestimated BF% in comparison to the reference method. Finally, in both genders, Lin's concordance correlation coefficient showed a strong agreement. More specifically the DXA value was ρc = 0.943 (95% CI = 0.775 to 0.950) and the mBCA value was ρc = 0.948 (95% CI = 0.778 to 0.978). Our analysis showed a strong agreement between the two methods as reflected in the range of BF%. These results show that mBCA and DXA are comparable methods for measuring body composition with higher body fat percentages. However, due to broad limits of agreement, we can only recommend mBCA for groups of populations. © 2017 Wiley Periodicals, Inc.

  1. Impeded Dark Matter

    SciTech Connect

    Kopp, Joachim; Liu, Jia; Slatyer, Tracy

    Here, we consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario \\Impeded Dark Matter". We also demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may evenmore » be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. Furthermore, for positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.« less

  2. Impeded Dark Matter

    DOE PAGES

    Kopp, Joachim; Liu, Jia; Slatyer, Tracy; ...

    2016-12-12

    Here, we consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario \\Impeded Dark Matter". We also demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may evenmore » be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. Furthermore, for positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.« less

  3. An investigation of thrust, depth and the impedance cardiogram as measures of cardiopulmonary resuscitation efficacy in a porcine model of cardiac arrest.

    PubMed

    Howe, Andrew; O'Hare, Peter; Crawford, Paul; Delafont, Bruno; McAlister, Olibhear; Di Maio, Rebecca; Clutton, Eddie; Adgey, Jennifer; McEneaney, David

    2015-11-01

    Optimising the depth and rate of applied chest compressions following out of hospital cardiac arrest is crucial in maintaining end organ perfusion and improving survival. The impedance cardiogram (ICG) measured via defibrillator pads produces a characteristic waveform during chest compressions with the potential to provide feedback on cardiopulmonary resuscitation (CPR) and enhance performance. The objective of this pre-clinical study was to investigate the relationship between mechanical and physiological markers of CPR efficacy in a porcine model and examine the strength of correlation between the ICG amplitude, compression depth and end-tidal CO2 (ETCO2). Two experiments were performed using 24 swine (12 per experiment). For experiment 1, ventricular fibrillation (VF) was induced and mechanical CPR commenced at varying thrusts (0-60 kg) for 2 min intervals. Chest compression depth was recorded using a Philips QCPR device with additional recording of invasive physiological parameters: systolic blood pressure, ETCO2, cardiac output and carotid flow. For experiment 2, VF was induced and mechanical CPR commenced at varying depths (0-5 cm) for 2 min intervals. The ICG was recorded via defibrillator pads attached to the animal's sternum and connected to a Heartsine 500 P defibrillator. ICG amplitude, chest compression depth, systolic blood pressure and ETCO2 were recorded during each cycle. In both experiments the within-animal correlation between the measured parameters was assessed using a mixed effect model. In experiment 1 moderate within-animal correlations were observed between physiological parameters and compression depth (r=0.69-0.77) and thrust (r=0.66-0.82). A moderate correlation was observed between compression depth and thrust (r=0.75). In experiment 2 a strong within-animal correlation and moderate overall correlations were observed between ICG amplitude and compression depth (r=0.89, r=0.79) and ETCO2 (r=0.85, r=0.64). In this porcine model of induced

  4. Superconducting active impedance converter

    DOEpatents

    Ginley, D.S.; Hietala, V.M.; Martens, J.S.

    1993-11-16

    A transimpedance amplifier for use with high temperature superconducting, other superconducting, and conventional semiconductors allows for appropriate signal amplification and impedance matching to processing electronics. The amplifier incorporates the superconducting flux flow transistor into a differential amplifier configuration which allows for operation over a wide temperature range, and is characterized by high gain, relatively low noise, and response times less than 200 picoseconds over at least a 10-80 K. temperature range. The invention is particularly useful when a signal derived from either far-IR focal plane detectors or from Josephson junctions is to be processed by higher signal/higher impedance electronics, such as conventional semiconductor technology. 12 figures.

  5. Superconducting active impedance converter

    DOEpatents

    Ginley, David S.; Hietala, Vincent M.; Martens, Jon S.

    1993-01-01

    A transimpedance amplifier for use with high temperature superconducting, other superconducting, and conventional semiconductor allows for appropriate signal amplification and impedance matching to processing electronics. The amplifier incorporates the superconducting flux flow transistor into a differential amplifier configuration which allows for operation over a wide temperature range, and is characterized by high gain, relatively low noise, and response times less than 200 picoseconds over at least a 10-80 K. temperature range. The invention is particularly useful when a signal derived from either far-IR focal plane detectors or from Josephson junctions is to be processed by higher signal/higher impedance electronics, such as conventional semiconductor technology.

  6. Mechanical Impedance Modeling of Human Arm: A survey

    NASA Astrophysics Data System (ADS)

    Puzi, A. Ahmad; Sidek, S. N.; Sado, F.

    2017-03-01

    Human arm mechanical impedance plays a vital role in describing motion ability of the upper limb. One of the impedance parameters is stiffness which is defined as the ratio of an applied force to the measured deformation of the muscle. The arm mechanical impedance modeling is useful in order to develop a better controller for system that interacts with human as such an automated robot-assisted platform for automated rehabilitation training. The aim of the survey is to summarize the existing mechanical impedance models of human upper limb so to justify the need to have an improved version of the arm model in order to facilitate the development of better controller of such systems with ever increase in complexity. In particular, the paper will address the following issue: Human motor control and motor learning, constant and variable impedance models, methods for measuring mechanical impedance and mechanical impedance modeling techniques.

  7. Broadband electrical impedance matching for piezoelectric ultrasound transducers.

    PubMed

    Huang, Haiying; Paramo, Daniel

    2011-12-01

    This paper presents a systematic method for designing broadband electrical impedance matching networks for piezoelectric ultrasound transducers. The design process involves three steps: 1) determine the equivalent circuit of the unmatched piezoelectric transducer based on its measured admittance; 2) design a set of impedance matching networks using a computerized Smith chart; and 3) establish the simulation model of the matched transducer to evaluate the gain and bandwidth of the impedance matching networks. The effectiveness of the presented approach is demonstrated through the design, implementation, and characterization of impedance matching networks for a broadband acoustic emission sensor. The impedance matching network improved the power of the acquired signal by 9 times.

  8. LONGITUDINAL IMPEDANCE OF THE SQUID GIANT AXON

    PubMed Central

    Cole, Kenneth S.; Baker, Richard F.

    1941-01-01

    Longitudinal alternating current impedance measurements have been made on the squid giant axon over the frequency range from 30 cycles per second to 200 kc. per second. Large sea water electrodes were used and the inter-electrode length was immersed in oil. The impedance at high frequency was approximately as predicted theoretically on the basis of the poorly conducting dielectric characteristics of the membrane previously determined. For the large majority of the axons, the impedance reached a maximum at a low frequency and the reactance then vanished at a frequency between 150 and 300 cycles per second. Below this frequency, the reactance was inductive, reaching a maximum and then approaching zero as the frequency was decreased. The inductive reactance is a property of the axon and requires that it contain an inductive structure. The variation of the impedance with interpolar distance indicates that the inductance is in the membrane. The impedance characteristics of the membrane as calculated from the measured longitudinal impedance of the axon may be expressed by an equivalent membrane circuit containing inductance, capacity, and resistance. For a square centimeter of membrane the capacity of 1 µf with dielectric loss is shunted by the series combination of a resistance of 400 ohms and an inductance of one-fifth henry. PMID:19873252

  9. Electrical Impedance Spectroscopy Study of Biological Tissues

    PubMed Central

    Dean, D.A.; Ramanathan, T.; Machado, D.; Sundararajan, R.

    2008-01-01

    The objective of this study was to investigate the electrical impedance properties of rat lung and other tissues ex vivo using Electrical Impedance Spectroscopy. Rat lungs (both electroporated and naïve (untreated)), and mesenteric vessels (naïve) were harvested from male Sprague-Dawley rats; their electrical impedance were measured using a Solartron 1290 impedance analyzer. Mouse lung and heart samples (naïve) were also studied. The resistance (Real Z, ohm) and the reactance (Im Z, negative ohm)) magnitudes and hence the Cole-Cole (Real Z versus Im Z) plots are different for the electroporated lung and the naive lung. The results confirm the close relationship between the structure and the functional characteristic. These also vary for the different biological tissues studied. The impedance values were higher at low frequencies compared to those at high frequencies. This study is of practical interest for biological applications of electrical pulses, such as electroporation, whose efficacy depends on cell type and its electrical impedance characteristics. PMID:19255614

  10. Robust Magnetotelluric Impedance Estimation

    NASA Astrophysics Data System (ADS)

    Sutarno, D.

    2010-12-01

    Robust magnetotelluric (MT) response function estimators are now in standard use by the induction community. Properly devised and applied, these have ability to reduce the influence of unusual data (outliers). The estimators always yield impedance estimates which are better than the conventional least square (LS) estimation because the `real' MT data almost never satisfy the statistical assumptions of Gaussian distribution and stationary upon which normal spectral analysis is based. This paper discuses the development and application of robust estimation procedures which can be classified as M-estimators to MT data. Starting with the description of the estimators, special attention is addressed to the recent development of a bounded-influence robust estimation, including utilization of the Hilbert Transform (HT) operation on causal MT impedance functions. The resulting robust performances are illustrated using synthetic as well as real MT data.

  11. High input impedance amplifier

    NASA Technical Reports Server (NTRS)

    Kleinberg, Leonard L.

    1995-01-01

    High input impedance amplifiers are provided which reduce the input impedance solely to a capacitive reactance, or, in a somewhat more complex design, provide an extremely high essentially infinite, capacitive reactance. In one embodiment, where the input impedance is reduced in essence, to solely a capacitive reactance, an operational amplifier in a follower configuration is driven at its non-inverting input and a resistor with a predetermined magnitude is connected between the inverting and non-inverting inputs. A second embodiment eliminates the capacitance from the input by adding a second stage to the first embodiment. The second stage is a second operational amplifier in a non-inverting gain-stage configuration where the output of the first follower stage drives the non-inverting input of the second stage and the output of the second stage is fed back to the non-inverting input of the first stage through a capacitor of a predetermined magnitude. These amplifiers, while generally useful, are very useful as sensor buffer amplifiers that may eliminate significant sources of error.

  12. Bioelectrical Impedance and Body Composition Assessment

    ERIC Educational Resources Information Center

    Martino, Mike

    2006-01-01

    This article discusses field tests that can be used in physical education programs. The most common field tests are anthropometric measurements, which include body mass index (BMI), girth measurements, and skinfold testing. Another field test that is gaining popularity is bioelectrical impedance analysis (BIA). Each method has particular strengths…

  13. Impedance Matching of Tapered Slot Antenna using a Dielectric Transformer

    NASA Technical Reports Server (NTRS)

    Simons, R. N.; Lee, R. Q.

    1998-01-01

    A new impedance matching technique for tapered slot antennas using a dielectric transformer is presented. The technique is demonstrated by measuring the input impedance, Voltage Standing Wave Ratio (VSWR) and the gain of a Vivaldi antenna (VA). Measured results at Ka-Band frequencies are presented and discussed.

  14. RHIC ABORT KICKER WITH REDUCED COUPLING IMPEDANCE.

    SciTech Connect

    HAHN,H.; DAVINO,D.

    2002-06-02

    Kicker magnets typically represent the most important contributors to the transverse impedance budget of accelerators and storage rings. Methods of reducing the impedance value of the SNS extraction kicker presently under construction and, in view of a future performance upgrade, that of the RHIC abort kicker have been thoroughly studied at this laboratory. In this paper, the investigation of a potential improvement from using ferrite different from the BNL standard CMD5005 is reported. Permeability measurements of several ferrite types have been performed. Measurements on two kicker magnets using CMD5005 and C2050 suggest that the impedance of a magnet without externalmore » resistive damping, such as the RHIC abort kicker, would benefit.« less

  15. Assessing the reliability of FTIR spectroscopy measurements and validity of bioelectrical impedance analysis as a surrogate measure of body composition among children and adolescents aged 8-19 years attending schools in Kampala, Uganda.

    PubMed

    Ndagire, Catherine T; Muyonga, John H; Isabirye, Dan; Odur, Benard; Somda, Serge M A; Bukenya, Richard; Andrade, Juan E; Nakimbugwe, Dorothy

    2018-06-04

    Accurate measurement of body composition in children and adolescents is important as the quantities of fat and fat-free mass have implications for health risk. The objectives of the present study were: to determine the reliability of Fourier Transform Infrared spectroscopy (FTIR) measurements and; compare the Fat Mass (FM), Fat Free Mass (FFM) and body fat percentage (%BF) values determined by bioelectrical impedance analysis (BIA) to those determined by deuterium dilution method (DDM) to identify correlations and agreement between the two methods. A cross-sectional study was conducted among 203 children and adolescents aged 8-19 years attending schools in Kampala city, Uganda. Pearson product-moment correlation at 5% significance level was considered for assessing correlations. Bland Altman analysis was used to examine the agreement between of FTIR measurements and between estimates by DDM and BIA.. Reliability of measurements was determined by Cronbach's alpha. There was good agreement between the in vivo D 2 O saliva enrichment measurements at 3 and 4 h among the studied age groups based on Bland-Altman plots. Cronbach's alpha revealed that measurements of D 2 O saliva enrichment had very good reliability. For children and young adolescents, DDM and BIA gave similar estimates of FFM, FM, and %BF. Among older adolescents, BIA significantly over-estimated FFM and significantly under-estimated FM and %BF compared to estimates by DDM. The correlation between FFM, FM and %BF estimates by DDM and BIA was high and significant among young and older adolescents and for FFM among children. Reliability of the FTIR spectroscopy measurements was very good among the studied population. BIA is suitable for assessing body composition among children (8-9 years) and young adolescents (10-14 years) but not among older adolescents (15-19 years) in Uganda. The body composition measurements of older adolescents determined by DDM can be predicted using those provided by BIA using

  16. Damage Detection Based on Power Dissipation Measured with PZT Sensors through the Combination of Electro-Mechanical Impedances and Guided Waves

    PubMed Central

    Sevillano, Enrique; Sun, Rui; Perera, Ricardo

    2016-01-01

    The use of piezoelectric ceramic transducers (such as Lead-Zirconate-Titanate—PZT) has become more and more widespread for Structural Health Monitoring (SHM) applications. Among all the techniques that are based on this smart sensing solution, guided waves and electro-mechanical impedance techniques have found wider acceptance, and so more studies and experimental works can be found containing these applications. However, even though these two techniques can be considered as complementary to each other, little work can be found focused on the combination of them in order to define a new and integrated damage detection procedure. In this work, this combination of techniques has been studied by proposing a new integrated damage indicator based on Electro-Mechanical Power Dissipation (EMPD). The applicability of this proposed technique has been tested through different experimental tests, with both lab-scale and real-scale structures. PMID:27164104

  17. Measurement of pulmonary arterial impedance and reflection from single-slice phase-contrast and steady-state free precession MRI

    NASA Astrophysics Data System (ADS)

    Leimbigler, Peter John

    Pulmonary arterial hypertension (PAH) alters vessel wall mechanics and vasomotor tone, driving up pulmonary hemodynamic variables such as pulse wave velocity, input and characteristic impedance, and pulse wave reflection magnitude. Heterogeneous treatment response necessitates frequent hemodynamic evaluation, for which right-heart catheterization (RHC) remains the gold standard; however, several disadvantages limit its frequency of use. In this work, a non-invasive magnetic resonance (MR) imaging protocol is developed to address the shortcomings of invasive hemodynamic monitoring and may support existing diagnostic procedures. First, accuracy and precision of the proposed method is characterized through linear uncertainty propagation and numerical simulation of the data-processing pipeline. Second, the MR protocol is tested in seven healthy adult volunteers. Third, a rapid version of the MR protocol is tested in a healthy volunteer, yielding good agreement with mean values obtained in the seven-volunteer study.

  18. Damage Detection Based on Power Dissipation Measured with PZT Sensors through the Combination of Electro-Mechanical Impedances and Guided Waves.

    PubMed

    Sevillano, Enrique; Sun, Rui; Perera, Ricardo

    2016-05-05

    The use of piezoelectric ceramic transducers (such as Lead-Zirconate-Titanate-PZT) has become more and more widespread for Structural Health Monitoring (SHM) applications. Among all the techniques that are based on this smart sensing solution, guided waves and electro-mechanical impedance techniques have found wider acceptance, and so more studies and experimental works can be found containing these applications. However, even though these two techniques can be considered as complementary to each other, little work can be found focused on the combination of them in order to define a new and integrated damage detection procedure. In this work, this combination of techniques has been studied by proposing a new integrated damage indicator based on Electro-Mechanical Power Dissipation (EMPD). The applicability of this proposed technique has been tested through different experimental tests, with both lab-scale and real-scale structures.

  19. Electrical impedance tomography

    PubMed Central

    Lobo, Beatriz; Hermosa, Cecilia; Abella, Ana

    2018-01-01

    Continuous assessment of respiratory status is one of the cornerstones of modern intensive care unit (ICU) monitoring systems. Electrical impedance tomography (EIT), although with some constraints, may play the lead as a new diagnostic and guiding tool for an adequate optimization of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and of end-expiratory lung volume (EELV) and contribute to titrate positive end-expiratory pressure (PEEP)/tidal volume combinations. It may also quantify gains (recruitment) and losses (overdistention or derecruitment), granting a more realistic evaluation of different ventilator modes or recruitment maneuvers, and helping in the identification of responders and non-responders to such maneuvers. Moreover, EIT also contributes to the management of life-threatening lung diseases such as pneumothorax, and aids in guiding fluid management in the critical care setting. Lastly, assessment of cardiac function and lung perfusion through electrical impedance is on the way. PMID:29430443

  20. ELECTRIC IMPEDANCE OF THE FROG EGG

    PubMed Central

    Cole, Kenneth S.; Guttman, Rita M.

    1942-01-01

    Electrical impedance measurements were made upon unfertilized and fertilized eggs of the leopard frog, Rana pipiens, over a frequency range of 0.05 to 10 kc. Average values of 170 ohm cm.2 were obtained for the plasma membrane resistance of the egg, 2.0 µf/cm.2 for the plasma membrane capacity, 86° for the phase angle of the membrane, and 570 ohm cm. for the specific resistance of the interior. These values did not change upon fertilization. No spontaneous rhythmical impedance changes such as have been found by Hubbard and Rothschild in the trout egg were found in frog eggs. PMID:19873312

  1. Understanding Artifacts in Impedance Spectroscopy

    DOE PAGES

    Veal, B. W.; Baldo, P. M.; Paulikas, A. P.; ...

    2014-11-22

    Four-terminal measurements of impedance spectra have long been troubled by the presence of high frequency artifacts that typically indicate unphysically large inductive behavior. In this paper, we follow up on the observation of Fleig et al., that voltage and current are necessarily measured in different locations of the potentiostat circuit, and that, typically, the electrometer input is a virtual ground. In this case, the capacitance of coaxial cables that connect sample electrodes to the potentiostat provides a high frequency conduction path to ground, so that some of the current that passes through the sample bypasses the electrometer. In four-electrode measurements,more » this mechanism produces the observed inductive artifacts. We examine a variety of simulated samples, with calculations compared to measurements of relevant circuits, to quantitatively investigate the nature of the artifacts. Model results agree with measurements when the leakage capacitances are properly included in the circuit analyses. With understanding of the origin of the inductive artifacts, the four-electrode method can be effectively utilized, enabling a combination of two-, three- and four-electrode measurements to be used to best advantage. Finally, using this combination of electrode configurations, temperature dependent measurements of SrTiO 3, Y 2O 3-stabilized ZrO 2, and In 2O 3 films deposited on YSZ substrates are presented.« less

  2. Ionospheric effects to antenna impedance

    NASA Technical Reports Server (NTRS)

    Bethke, K. H.

    1986-01-01

    The reciprocity between high power satellite antennas and the surrounding plasma are examined. The relevant plasma states for antenna impedance calculations are presented and plasma models, and hydrodynamic and kinetic theory, are discussed. A theory from which a variation in antenna impedance with regard to the radiated power can be calculated for a frequency range well above the plasma resonance frequency is give. The theory can include photo and secondary emission effects in antenna impedance calculations.

  3. On Impedance Spectroscopy of Supercapacitors

    NASA Astrophysics Data System (ADS)

    Uchaikin, V. V.; Sibatov, R. T.; Ambrozevich, A. S.

    2016-10-01

    Supercapacitors are often characterized by responses measured by methods of impedance spectroscopy. In the frequency domain these responses have the form of power-law functions or their linear combinations. The inverse Fourier transform leads to relaxation equations with integro-differential operators of fractional order under assumption that the frequency response is independent of the working voltage. To compare long-term relaxation kinetics predicted by these equations with the observed one, charging-discharging of supercapacitors (with nominal capacitances of 0.22, 0.47, and 1.0 F) have been studied by means of registration of the current response to a step voltage signal. It is established that the reaction of devices under study to variations of the charging regime disagrees with the model of a homogeneous linear response. It is demonstrated that relaxation is well described by a fractional stretched exponent.

  4. Residential neighborhood, geographic work environment, and work economic sector: associations with body fat measured by bioelectrical impedance in the RECORD Study.

    PubMed

    Lewin, Antoine; Pannier, Bruno; Méline, Julie; Karusisi, Noëlla; Thomas, Frédérique; Chaix, Basile

    2014-03-01

    Studies of associations between geographic environment and obesity have mostly examined body mass index and focused on residential neighborhoods. We investigated associations between residential neighborhoods, geographic work environments, and work economic sectors and the fat mass index (FMI) and percentage of fat mass (%FM). Data on 4331 participants from the French RECORD Study geolocated at their residence and workplace were analyzed. Body composition was assessed by bioelectrical impedance analyzers. Multilevel linear regression was used to investigate the determinants of FMI and %FM. After adjustment, among men, the FMI and %FM increased independently with decreasing density of population and educational level in the residential neighborhood. Among women, the residential educational level was related to the FMI and %FM. Among men, a higher FMI and %FM were observed among participants working in the construction and transportation/communication sectors than in the education sector. For women, the FMI was higher among participants working in the public administration and health/social work sectors than in the transport/communication sector. A long home-work distance was associated with a higher FMI among women. There was evidence that body mass index cannot fully capture work economic sector effects on fat mass. Public health interventions to reduce social/territorial disparities in obesity should also consider the different contexts to which the participants belong, such as residential environments and work economic sectors. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. A microfluidic device for label-free detection of Escherichia coli in drinking water using positive dielectrophoretic focusing, capturing, and impedance measurement.

    PubMed

    Kim, Myounggon; Jung, Taekeon; Kim, Youngjin; Lee, Changgeun; Woo, Kyungchul; Seol, Jae Hun; Yang, Sung

    2015-12-15

    While sensors that allow for high-throughput enumeration of microorganisms within drinking water are useful for water quality monitoring, it is particularly challenging to accurately quantify microorganisms that are present in low numbers (<100 CFU/mL) in a high-throughput manner. Negative dielectrophoresis (nDEP) is typically utilized in DEP-based cell focusing methods; however, due to its low conductivity, drinking water cannot be analyzed by this approach. Here, we report a positive DEP (pDEP)-based Escherichia coli detection system that is integrated with a focusing and sensing electrode. By incorporating a passivation layer, we avoided issues with adhesion of E. coli to the electrode, and achieved efficient cell focusing under high flow rate conditions (1500 μL/h). The resulting focused E. coli cells were then trapped on the sensor electrode, resulting in changes in impedance. The proposed system was evaluated using four different E. coli populations (150-1500 CFU/mL). We successfully enumerated populations as low as 300 CFU/mL within 1 min, and the signal variation was 1.13±0.37%. The device introduced in this study provides the basis for the development of portable, highly sensitive microorganism sensors that enable rapid detection of bacteria in drinking water. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Electrical impedance tomography.

    PubMed

    Costa, Eduardo L V; Lima, Raul Gonzalez; Amato, Marcelo B P

    2009-02-01

    Electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring tool that allows real-time imaging of ventilation. The purpose of this article is to discuss the fundamentals of EIT and to review the use of EIT in critical care patients. In addition to its established role in describing the distribution of alveolar ventilation, EIT has been shown to be a useful tool to detect lung collapse and monitor lung recruitment, both regionally and on a global basis. EIT has also been used to diagnose with high sensitivity incident pneumothoraces during mechanical ventilation. Additionally, with injection of hypertonic saline as a contrast agent, it is possible to estimate ventilation/perfusion distributions. EIT is cheap, noninvasive and allows continuous monitoring of ventilation. It is gaining acceptance as a valuable monitoring tool for the care of critical patients.

  7. Idiopathic pulmonary fibrosis is associated with increased impedance measures of reflux compared to non-fibrotic disease among pre-lung transplant patients.

    PubMed

    Gavini, S; Finn, R T; Lo, W-K; Goldberg, H J; Burakoff, R; Feldman, N; Chan, W W

    2015-09-01

    Gastroesophageal reflux (GER) has been associated with idiopathic pulmonary fibrosis (IPF), although the mechanism remains unclear. Gastroesophageal reflux/microaspiration may lead to lung fibrosis, while increased pulmonary workload may also worsen GER. Comparing the GER profile of IPF patients to chronic obstructive pulmonary disease (COPD) patients with similar lung function may help delineate the role of GER in IPF pathogenesis. This was a retrospective cohort study of IPF and COPD patients undergoing pre-lung transplant multichannel intraluminal impedance and pH study (MII-pH) off acid suppression at a tertiary center in 2008-2014. Patients with prior fundoplication were excluded. Baseline demographics, pulmonary function test, and MII-pH results were recorded. Univariate analyses were performed using Fisher's exact (binary variables) and Student's t (continuous variables) tests. Logistic regression was performed to adjust for potential confounders. A total of 90 subjects (54 IPF, 36 COPD) met inclusion criteria. Compared to COPD, IPF patients had increased total reflux episodes (65.9 vs 46.1, p = 0.02), proximal reflux episodes (30.3 vs 20.3, p = 0.04), and prevalence of abnormal total reflux episodes (38.9% vs 16.7%, p = 0.02). On multivariate analyses, abnormal total reflux episodes (OR: 4.9, p = 0.05) and bolus reflux exposure time (OR: 4, p = 0.04) remained significantly associated with IPF. Abnormal reflux was significantly more prevalent among IPF patients after controlling for lung disease severity. Gastroesophageal reflux/microaspiration likely plays a role in fibrosis in IPF. A significant portion of IPF patients had increased non-acid reflux. Therapies aiming to prevent reflux of gastric contents may be more beneficial than antisecretory medications alone in these patients. © 2015 John Wiley & Sons Ltd.

  8. Laparoscopic Nissen fundoplication mainly reduces the volume of acid reflux and potentially improves mucosal integrity up to the middle esophagus in neurologically impaired children detected by esophageal combined pH-multichannel intraluminal impedance measurements.

    PubMed

    Fukahori, Suguru; Yagi, Minoru; Ishii, Shinji; Asagiri, Kimio; Saikusa, Nobuyuki; Hashizume, Naoki; Yoshida, Motomu; Masui, Daisuke; Sakamoto, Saki; Tsuruhisa, Shihori; Kurahachi, Tomohiro; Tanaka, Yoshiaki

    2016-08-01

    The aim of this study was to evaluate detailed changes of gastroesophageal reflux disease (GERD) in children before and after laparoscopic Nissen fundoplication (LNF) utilizing esophageal combined pH-multichannel intraluminal impedance (pH/MII) measurements. Thirteen patients with neurological impairment, who received laparoscopic Nissen fundoplication (LNF) owing to refractory pathological GERD, were enrolled in this study. 24h pH/MII was conducted in all patients before and one year after LNF. Each parameter of the pH/MII was evaluated and compared each other. Both the mean pH index and bolus exposure index after LNF were significantly lower than those before LNF. The mean numbers of total and nonacid reflux episodes after LNF were significantly lower than those before LNF. The mean numbers of total, acid and nonacid proximal reflux episodes after LNF were significantly lower than those before LNF. The mean baseline impedance values from Z3 to Z6 after LNF were significantly higher than those before LNF. The present study provides new insights into the effects of LNF in pediatric patients, which prevents mainly acid reflux episodes from rising to the proximal esophagus, and is expected to improve the mucosal integrity up to the middle esophagus. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. The Influence of Segmental Impedance Analysis in Predicting Validity of Consumer Grade Bioelectrical Impedance Analysis Devices

    NASA Astrophysics Data System (ADS)

    Sharp, Andy; Heath, Jennifer; Peterson, Janet

    2008-05-01

    Consumer grade bioelectric impedance analysis (BIA) instruments measure the body's impedance at 50 kHz, and yield a quick estimate of percent body fat. The frequency dependence of the impedance gives more information about the current pathway and the response of different tissues. This study explores the impedance response of human tissue at a range of frequencies from 0.2 - 102 kHz using a four probe method and probe locations standard for segmental BIA research of the arm. The data at 50 kHz, for a 21 year old healthy Caucasian male (resistance of 180φ±10 and reactance of 33φ±2) is in agreement with previously reported values [1]. The frequency dependence is not consistent with simple circuit models commonly used in evaluating BIA data, and repeatability of measurements is problematic. This research will contribute to a better understanding of the inherent difficulties in estimating body fat using consumer grade BIA devices. [1] Chumlea, William C., Richard N. Baumgartner, and Alex F. Roche. ``Specific resistivity used to estimate fat-free mass from segmental body measures of bioelectrical impedance.'' Am J Clin Nutr 48 (1998): 7-15.

  10. Method of estimating pulse response using an impedance spectrum

    DOEpatents

    Morrison, John L; Morrison, William H; Christophersen, Jon P; Motloch, Chester G

    2014-10-21

    Electrochemical Impedance Spectrum data are used to predict pulse performance of an energy storage device. The impedance spectrum may be obtained in-situ. A simulation waveform includes a pulse wave with a period greater than or equal to the lowest frequency used in the impedance measurement. Fourier series coefficients of the pulse train can be obtained. The number of harmonic constituents in the Fourier series are selected so as to appropriately resolve the response, but the maximum frequency should be less than or equal to the highest frequency used in the impedance measurement. Using a current pulse as an example, the Fourier coefficients of the pulse are multiplied by the impedance spectrum at corresponding frequencies to obtain Fourier coefficients of the voltage response to the desired pulse. The Fourier coefficients of the response are then summed and reassembled to obtain the overall time domain estimate of the voltage using the Fourier series analysis.

  11. TRANSVERSE ELECTRIC IMPEDANCE OF NITELLA

    PubMed Central

    Curtis, Howard J.; Cole, Kenneth S.

    1937-01-01

    Alternating current measurements have been taken on single Nitella cells over a frequency range from 30 to 2,500,000 cycles per second with the current flow perpendicular to the axis of the cell. The measuring cells were so constructed that electrolytes of any desired concentration could be circulated during the course of the measurements. The cellulose wall which surrounds the cell is found to play an important part in the interpretation of the results obtained. In a mature cell, this cellulose has a specific resistance of about 1000 ohm cm. which is independent of the medium in which the cell is suspended. The thickness of the wall is computed to be about 10 µ. The cell membrane is found to be virtually non-conducting, and to have a capacity of 0.94 µf./cm.2 ± 10 per cent and a phase angle of 80° ± 4°. The specific resistances of the sap were difficult to compute from data on living cells and were unsatisfactory because they were very much dependent upon the medium, while measurements on extracted sap gave 58 ohm cm. ± 8 per cent which was independent of the medium. There are indications that the chloroplasts have impedance properties similar to those of living cells. PMID:19873046

  12. Impedance in School Screening Programs.

    ERIC Educational Resources Information Center

    Robarts, John T.

    1985-01-01

    This paper examines the controversy over use of impedance screening in public schools to identify students with hearing problems, including otitis media, a common ear condition in infants and young children. It cites research that questions the value of pure tone screening as a single test and raises critics' objections to the use of impedance,…

  13. Ultra-wideband impedance sensor

    DOEpatents

    McEwan, Thomas E.

    1999-01-01

    The ultra-wideband impedance sensor (UWBZ sensor, or Z-sensor) is implemented in differential and single-ended configurations. The differential UWBZ sensor employs a sub-nanosecond impulse to determine the balance of an impedance bridge. The bridge is configured as a differential sample-and-hold circuit that has a reference impedance side and an unknown impedance side. The unknown impedance side includes a short transmission line whose impedance is a function of the near proximity of objects. The single-ended UWBZ sensor eliminates the reference side of the bridge and is formed of a sample and hold circuit having a transmission line whose impedance is a function of the near proximity of objects. The sensing range of the transmission line is bounded by the two-way travel time of the impulse, thereby eliminating spurious Doppler modes from large distant objects that would occur in a microwave CW impedance bridge. Thus, the UWBZ sensor is a range-gated proximity sensor. The Z-sensor senses the near proximity of various materials such as metal, plastic, wood, petroleum products, and living tissue. It is much like a capacitance sensor, yet it is impervious to moisture. One broad application area is the general replacement of magnetic sensors, particularly where nonferrous materials need to be sensed. Another broad application area is sensing full/empty levels in tanks, vats and silos, e.g., a full/empty switch in water or petroleum tanks.

  14. Ultra-wideband impedance sensor

    DOEpatents

    McEwan, T.E.

    1999-03-16

    The ultra-wideband impedance sensor (UWBZ sensor, or Z-sensor) is implemented in differential and single-ended configurations. The differential UWBZ sensor employs a sub-nanosecond impulse to determine the balance of an impedance bridge. The bridge is configured as a differential sample-and-hold circuit that has a reference impedance side and an unknown impedance side. The unknown impedance side includes a short transmission line whose impedance is a function of the near proximity of objects. The single-ended UWBZ sensor eliminates the reference side of the bridge and is formed of a sample and hold circuit having a transmission line whose impedance is a function of the near proximity of objects. The sensing range of the transmission line is bounded by the two-way travel time of the impulse, thereby eliminating spurious Doppler modes from large distant objects that would occur in a microwave CW impedance bridge. Thus, the UWBZ sensor is a range-gated proximity sensor. The Z-sensor senses the near proximity of various materials such as metal, plastic, wood, petroleum products, and living tissue. It is much like a capacitance sensor, yet it is impervious to moisture. One broad application area is the general replacement of magnetic sensors, particularly where nonferrous materials need to be sensed. Another broad application area is sensing full/empty levels in tanks, vats and silos, e.g., a full/empty switch in water or petroleum tanks. 2 figs.

  15. Mechanical Impedance of the Human Body in the Horizontal Direction

    NASA Astrophysics Data System (ADS)

    Holmlund, P.; Lundström, R.

    1998-08-01

    The mechanical impedance of the seated human body in horizontal directions (fore-and-aft and lateral) was measured during different experimental conditions, such as vibration level (0·25-1·4 m/s2r.m.s.), frequency (1·13-80 Hz), body weight (54-93 kg), upper body posture (relaxed and erect) and gender. The outcome showed that impedance, normalized by the sitting weight, varies with direction, level, posture and gender. Generally the impedance spectra show one peak for the fore-and-aft (X) direction while two peaks are found in the lateral (Y) direction. Males showed a lower normalized impedance than females. Increasing fore-and-aft vibration decreases the frequency at which maximum impedance occurs but also reduces the overall magnitude. For the lateral direction a more complex pattern was found. The frequency of impedance peaks are constant with increasing vibration level. The magnitude of the second peak decreases when changing posture from erect to relaxed. Males showed a higher impedance magnitude than females and a greater dip between the two peaks. The impedance spectra for the two horizontal directions have different shapes. This supports the idea of treating them differently; such as with respect to risk assessments and development of preventative measures.

  16. Changes in transthoracic electrical impedance at high altitude.

    PubMed

    Hoon, R S; Balasubramanian, V; Tiwari, S C; Mathew, O P; Behl, A; Sharma, S C; Chadha, K S

    1977-01-01

    Mean transthoracic electrical impedance (impedance) which is inversely related to intrathoracic extravascular fluid volume was measured in 121 normal healthy volunteers at sea-level and at 3658 metres altitude. Fifty (group A) reached the high altitude location after an hour's journey in a pressurised aircraft. Twenty-five (group D) underwent slow road ascent including acclimatisation en route. Thirty permanent residents (group B) and 16 temporary residents at high altitude (group C) were also studied. Serial studies in the 30 subjects of group A who developed symptoms of high altidue sickness showed a significant decrease of impedance up to the fourth day of exposure to high altitude which later returned to normal. The 4 volunteers who developed severe symptoms showed the largest drop in impedance. A case of acute pulmonary oedema developing at 4300 metres showed an impedance value of 24-1 ohms on admission. After effective treatment the impedance increased by 11-9 to 36-0 ohms. Twenty asymptomatic subjects of group A and 25 of group D showed a small average increase in impedance values at high altitude. These obstructions suggest that measurement of transthoracic electrical impedance may be a valuable means of detecting incipient high altitude pulmonary oedema.

  17. Geometric beam coupling impedance of LHC secondary collimators

    NASA Astrophysics Data System (ADS)

    Frasciello, Oscar; Tomassini, Sandro; Zobov, Mikhail; Salvant, Benoit; Grudiev, Alexej; Mounet, Nicolas

    2016-02-01

    The High Luminosity LHC project is aimed at increasing the LHC luminosity by an order of magnitude. One of the key ingredients to achieve the luminosity goal is the beam intensity increase. In order to keep beam instabilities under control and to avoid excessive power losses a careful design of new vacuum chamber components and an improvement of the present LHC impedance model are required. Collimators are among the major impedance contributors. Measurements with beam have revealed that the betatron coherent tune shifts were higher by about a factor of 2 with respect to the theoretical predictions based on the LHC impedance model up to 2012. In that model the resistive wall impedance has been considered as the dominating impedance contribution for collimators. By carefully simulating also their geometric impedance we have contributed to the update of the LHC impedance model, reaching also a better agreement between the measured and simulated betatron tune shifts. During the just ended LHC Long Shutdown I (LSI), TCS/TCT collimators were replaced by new devices embedding BPMs and TT2-111R ferrite blocks. We present here preliminary estimations of their broad-band impedance, showing that an increase of about 20% is expected in the kick factors with respect to previous collimators without BPMs.

  18. Comparison of the multichannel intraluminal impedance pH and conventional pH for measuring esophageal acid exposure: a propensity score-matched analysis.

    PubMed

    Hoshino, Masato; Omura, Nobuo; Yano, Fumiaki; Tsuboi, Kazuto; Yamamoto, Se Ryung; Akimoto, Shunsuke; Masuda, Takahiro; Kashiwagi, Hideyuki; Yanaga, Katsuhiko

    2017-12-01

    The modalities for evaluating acid reflux in medical care for gastroesophageal reflux disease (GERD) include conventional pH (C-pH), wireless pH (Bravo ® ) and multichannel intraluminal impedance pH (MII-pH), which have been reported to vary with respect to the duration of acid reflux. In this study, we examined the difference between the acid reflux in C-pH and MII-pH among patients with GERD. Prior to initial laparoscopic fundoplication carried out on 297 cases from December 1994 to April 2016, an upper gastrointestinal endoscopy and C-pH or MII-pH were conducted. A propensity score-matched analysis was carried out about five factors including age, sex, BMI, the extent of reflux esophagitis (Los Angeles classification), and the presence of hiatal hernia (HH), ultimately leading to the creation of a C-pH group (81 cases) and MII-pH group (81 cases) as the subjects. Concerning pH < 4 holding time (18.9 vs. 7.3%, p < 0.001), DeMeester score (58.5 vs. 24.4, p < 0.001), and the number of times reflux continued for longer than 5 min (8.8 vs. 4.1 times/day, p = 0.002), the C-pH group had significantly higher values for each, while the positive rate of acid reflux (Positive pH) was significantly higher in the C-pH group (p < 0.001), at 80% in the C-pH group and 42% in the MII-pH group. In terms of the correlation between the extent of reflux esophagitis and pH < 4 holding time, a moderate level of positive correlation was seen in both the C-pH group and MII-pH group (r of each = 0.427, r = 0.408); moreover, regardless of the presence of HH, the holding time was significantly higher in the C-pH group than the MII-pH group (p of each <0.001, p = 0.040). While the values of each parameter regarding acid reflux are calculated as lower in MII-pH than in C-pH, there is no difference in the evaluation of the pathology between the two modalities.

  19. Relationships among dual-energy X-ray absorptiometry (DXA), bioelectrical impedance (BIA), and ultrasound measurements of body composition of swine

    USDA-ARS?s Scientific Manuscript database

    In three separate studies (156 pigs total), DXA, BIA, and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body l...

  20. A power saving protocol for impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Bîrlea, Nicolae Marius

    2017-12-01

    Because power saving is a main concern of wearable devices we present here a transient method with a low power demand for impedance spectroscopy of the skin, but the idea is valid for other test materials. The used signal is an electrical pulse (the ON period) followed by a pause (the OFF period) when the electrodes do not consume current from the power supply. The method has the advantage of being able to measure at once the frequency characteristics of the impedance and is well suited for the time varying bioimpedance. In addition, this kind of measurement creates a more direct and explicit relationship between the lumped elements of the electrical model and the measured signal.

  1. ELECTRIC IMPEDANCE OF NITELLA DURING ACTIVITY

    PubMed Central

    Cole, Kenneth S.; Curtis, Howard J.

    1938-01-01

    The changes in the alternating current impedance which occur during activity of cells of the fresh water plant Nitella have been measured with the current flow normal to the cell axis, at eight frequencies from 0.05 to 20 kilocycles per second, and with simultaneous records of the action potential under the impedance electrodes. At each frequency the resting cell was balanced in a Wheatstone bridge with a cathode ray oscillograph, and after electrical stimulation at one end of the cell, the changes in the complex impedance were determined from the bridge unbalance recorded by motion pictures of the oscillograph figure. An extension of the previous technique of interpretation of the transverse impedance shows that the normal membrane capacity of 0.9 µf./cm.2 decreases about 15 per cent without change of phase angle, while the membrane resistance decreases from 105 ohm cm.2 to about 500 ohm cm.2 during the passage of the excitation wave. This membrane change occurs during the latter part of the rising phase of the action potential, and it is shown that the membrane electromotive force remains unchanged until nearly the same time. The part of the action potential preceding these membrane changes is probably a passive fall of potential ahead of a partial short circuit. PMID:19873091

  2. I/O impedance controller

    DOEpatents

    Ruesch, Rodney; Jenkins, Philip N.; Ma, Nan

    2004-03-09

    There is disclosed apparatus and apparatus for impedance control to provide for controlling the impedance of a communication circuit using an all-digital impedance control circuit wherein one or more control bits are used to tune the output impedance. In one example embodiment, the impedance control circuit is fabricated using circuit components found in a standard macro library of a computer aided design system. According to another example embodiment, there is provided a control for an output driver on an integrated circuit ("IC") device to provide for forming a resistor divider network with the output driver and a resistor off the IC device so that the divider network produces an output voltage, comparing the output voltage of the divider network with a reference voltage, and adjusting the output impedance of the output driver to attempt to match the output voltage of the divider network and the reference voltage. Also disclosed is over-sampling the divider network voltage, storing the results of the over sampling, repeating the over-sampling and storing, averaging the results of multiple over sampling operations, controlling the impedance with a plurality of bits forming a word, and updating the value of the word by only one least significant bit at a time.

  3. Bioelectrical impedance analysis of bovine milk fat

    NASA Astrophysics Data System (ADS)

    Veiga, E. A.; Bertemes-Filho, P.

    2012-12-01

    Three samples of 250ml at home temperature of 20°C were obtained from whole, low fat and fat free bovine UHT milk. They were analysed by measuring both impedance spectra and dc conductivity in order to establish the relationship between samples related to fat content. An impedance measuring system was developed, which is based on digital oscilloscope, a current source and a FPGA. Data was measured by the oscilloscope in the frequency 1 kHz to 100 kHz. It was showed that there is approximately 7.9% difference in the conductivity between whole and low fat milk whereas 15.9% between low fat and free fat one. The change of fatness in the milk can be significantly sensed by both impedance spectra measurements and dc conductivity. This result might be useful for detecting fat content of milk in a very simple way and also may help the development of sensors for measuring milk quality, as for example the detection of mastitis.

  4. Optically coupled methods for microwave impedance microscopy

    NASA Astrophysics Data System (ADS)

    Johnston, Scott R.; Ma, Eric Yue; Shen, Zhi-Xun

    2018-04-01

    Scanning Microwave Impedance Microscopy (MIM) measurement of photoconductivity with 50 nm resolution is demonstrated using a modulated optical source. The use of a modulated source allows for the measurement of photoconductivity in a single scan without a reference region on the sample, as well as removing most topographical artifacts and enhancing signal to noise as compared with unmodulated measurement. A broadband light source with a tunable monochrometer is then used to measure energy resolved photoconductivity with the same methodology. Finally, a pulsed optical source is used to measure local photo-carrier lifetimes via MIM, using the same 50 nm resolution tip.

  5. Twelve years evolution of skin as seen by electrical impedance

    NASA Astrophysics Data System (ADS)

    Nicander, Ingrid; Emtestam, Lennart; Åberg, Peter; Ollmar, Stig

    2010-04-01

    Twelve years ago we reported an electrical impedance baseline study related to age, sex and body locations. The results showed significant differences between different anatomical locations and ages. In this study, the same participants were recalled to explore how the skin had evolved at the individual level over time. A total of 50 subjects, divided into an older and a younger group, were recalled for measurements of electrical impedance at eight anatomical locations. Readings were taken with an electrical impedance spectrometer. Information was extracted from the impedance spectra using indices based on magnitude and phase at two frequencies as in the earlier study. All included body sites had undergone alterations over time, and the size of the changes varied at different locations. The results also showed that changes in the younger group were different over time compared with the older group. In conclusion: Electrical impedance can be used to monitor skin evolution over time and baseline characteristics differ between various locations.

  6. AC impedance study of degradation of porous nickel battery electrodes

    NASA Technical Reports Server (NTRS)

    Lenhart, Stephen J.; Macdonald, D. D.; Pound, B. G.

    1987-01-01

    AC impedance spectra of porous nickel battery electrodes were recorded periodically during charge/discharge cycling in concentrated KOH solution at various temperatures. A transmission line model (TLM) was adopted to represent the impedance of the porous electrodes, and various model parameters were adjusted in a curve fitting routine to reproduce the experimental impedances. Degradation processes were deduced from changes in model parameters with electrode cycling time. In developing the TLM, impedance spectra of planar (nonporous) electrodes were used to represent the pore wall and backing plate interfacial impedances. These data were measured over a range of potentials and temperatures, and an equivalent circuit model was adopted to represent the planar electrode data. Cyclic voltammetry was used to study the characteristics of the oxygen evolution reaction on planar nickel electrodes during charging, since oxygen evolution can affect battery electrode charging efficiency and ultimately electrode cycle life if the overpotential for oxygen evolution is sufficiently low.

  7. Reactanceless synthesized impedance bandpass amplifier

    NASA Technical Reports Server (NTRS)

    Kleinberg, L. L. (Inventor)

    1985-01-01

    An active R bandpass filter network is formed by four operational amplifier stages interconnected by discrete resistances. One pair of stages synthesize an equivalent input impedance of an inductance (L sub eq) in parallel with a discrete resistance (R sub o) while the second pair of stages synthesizes an equivalent input impedance of a capacitance (C sub eq) serially coupled to another discrete resistance (R sub i) coupled in parallel with the first two stages. The equivalent input impedances aggregately define a tuned resonant bandpass filter in the roll-off regions of the operational amplifiers.

  8. Development on electromagnetic impedance function modeling and its estimation

    NASA Astrophysics Data System (ADS)

    Sutarno, D.

    2015-09-01

    Today the Electromagnetic methods such as magnetotellurics (MT) and controlled sources audio MT (CSAMT) is used in a broad variety of applications. Its usefulness in poor seismic areas and its negligible environmental impact are integral parts of effective exploration at minimum cost. As exploration was forced into more difficult areas, the importance of MT and CSAMT, in conjunction with other techniques, has tended to grow continuously. However, there are obviously important and difficult problems remaining to be solved concerning our ability to collect process and interpret MT as well as CSAMT in complex 3D structural environments. This talk aim at reviewing and discussing the recent development on MT as well as CSAMT impedance functions modeling, and also some improvements on estimation procedures for the corresponding impedance functions. In MT impedance modeling, research efforts focus on developing numerical method for computing the impedance functions of three dimensionally (3-D) earth resistivity models. On that reason, 3-D finite elements numerical modeling for the impedances is developed based on edge element method. Whereas, in the CSAMT case, the efforts were focused to accomplish the non-plane wave problem in the corresponding impedance functions. Concerning estimation of MT and CSAMT impedance functions, researches were focused on improving quality of the estimates. On that objective, non-linear regression approach based on the robust M-estimators and the Hilbert transform operating on the causal transfer functions, were used to dealing with outliers (abnormal data) which are frequently superimposed on a normal ambient MT as well as CSAMT noise fields. As validated, the proposed MT impedance modeling method gives acceptable results for standard three dimensional resistivity models. Whilst, the full solution based modeling that accommodate the non-plane wave effect for CSAMT impedances is applied for all measurement zones, including near-, transition

  9. Development on electromagnetic impedance function modeling and its estimation

    SciTech Connect

    Sutarno, D., E-mail: Sutarno@fi.itb.ac.id

    2015-09-30

    Today the Electromagnetic methods such as magnetotellurics (MT) and controlled sources audio MT (CSAMT) is used in a broad variety of applications. Its usefulness in poor seismic areas and its negligible environmental impact are integral parts of effective exploration at minimum cost. As exploration was forced into more difficult areas, the importance of MT and CSAMT, in conjunction with other techniques, has tended to grow continuously. However, there are obviously important and difficult problems remaining to be solved concerning our ability to collect process and interpret MT as well as CSAMT in complex 3D structural environments. This talk aim atmore » reviewing and discussing the recent development on MT as well as CSAMT impedance functions modeling, and also some improvements on estimation procedures for the corresponding impedance functions. In MT impedance modeling, research efforts focus on developing numerical method for computing the impedance functions of three dimensionally (3-D) earth resistivity models. On that reason, 3-D finite elements numerical modeling for the impedances is developed based on edge element method. Whereas, in the CSAMT case, the efforts were focused to accomplish the non-plane wave problem in the corresponding impedance functions. Concerning estimation of MT and CSAMT impedance functions, researches were focused on improving quality of the estimates. On that objective, non-linear regression approach based on the robust M-estimators and the Hilbert transform operating on the causal transfer functions, were used to dealing with outliers (abnormal data) which are frequently superimposed on a normal ambient MT as well as CSAMT noise fields. As validated, the proposed MT impedance modeling method gives acceptable results for standard three dimensional resistivity models. Whilst, the full solution based modeling that accommodate the non-plane wave effect for CSAMT impedances is applied for all measurement zones, including near

  10. Image Reconstruction Under Contact Impedance Effect in Micro Electrical Impedance Tomography Sensors.

    PubMed

    Liu, Xiayi; Yao, Jiafeng; Zhao, Tong; Obara, Hiromichi; Cui, Yahui; Takei, Masahiro

    2018-06-01

    Contact impedance has an important effect on micro electrical impedance tomography (EIT) sensors compared to conventional macro sensors. In the present work, a complex contact impedance effect ratio ξ is defined to quantitatively evaluate the effect of the contact impedance on the accuracy of the reconstructed images by micro EIT. Quality of the reconstructed image under various ξ is estimated by the phantom simulation to find the optimum algorithm. The generalized vector sampled pattern matching (GVSPM) method reveals the best image quality and the best tolerance to ξ. Moreover, the images of yeast cells sedimentary distribution in a multilayered microchannel are reconstructed by the GVSPM method under various mean magnitudes of contact impedance effect ratio |ξ|. The result shows that the best image quality that has the smallest voltage error U E = 0.581 is achieved with measurement frequency f = 1 MHz and mean magnitude |ξ| = 26. In addition, the reconstructed images of cells distribution become improper while f < 10 kHz and mean value of |ξ| > 2400.

  11. Intrathoracic impedance monitor alarm in a patient with cardiac resynchronisation therapy and advanced lung carcinoma.

    PubMed

    Cvijić, Marta; Zižek, David; Antolič, Bor; Zupan, Igor

    2013-01-01

    The intrathoracic impedance monitor system measures impedance between the device case and the right ventricular coil and reflects intrathoracic fluid status. It is used to detect early volume overload in patients with chronic heart failure. We report a case of inappropriate activation of the intrathoracic impedance monitor alarm in a patient with epidermoid lung cancer and pleural carcinosis.

  12. Impedance spectroscopy for the detection and identification of unknown toxins

    NASA Astrophysics Data System (ADS)

    Riggs, B. C.; Plopper, G. E.; Paluh, J. L.; Phamduy, T. B.; Corr, D. T.; Chrisey, D. B.

    2012-06-01

    Advancements in biological and chemical warfare has allowed for the creation of novel toxins necessitating a universal, real-time sensor. We have used a function-based biosensor employing impedance spectroscopy using a low current density AC signal over a range of frequencies (62.5 Hz-64 kHz) to measure the electrical impedance of a confluent epithelial cell monolayer at 120 sec intervals. Madin Darby canine kidney (MDCK) epithelial cells were grown to confluence on thin film interdigitated gold electrodes. A stable impedance measurement of 2200 Ω was found after 24 hrs of growth. After exposure to cytotoxins anthrax lethal toxin and etoposide, the impedance decreased in a linear fashion resulting in a 50% drop in impedance over 50hrs showing significant difference from the control sample (~20% decrease). Immunofluorescent imaging showed that apoptosis was induced through the addition of toxins. Similarities of the impedance signal shows that the mechanism of cellular death was the same between ALT and etoposide. A revised equivalent circuit model was employed in order to quantify morphological changes in the cell monolayer such as tight junction integrity and cell surface area coverage. This model showed a faster response to cytotoxin (2 hrs) compared to raw measurements (20 hrs). We demonstrate that herein that impedance spectroscopy of epithelial monolayers serves as a real-time non-destructive sensor for unknown pathogens.

  13. Altered Impedance of Ear Acupuncture Point MT2 in Breast Cancer Patients: A Preliminary Observation

    PubMed Central

    Yang, Huayuan; Wang, Pin; Liu, Tangyi; Tang, Wenchao

    2015-01-01

    Skin impedance at acupuncture points (APs) has been used as a diagnostic aid for more than 50 years. In this study, we have a diagnostic tool (JXT-2008) to measure the skin impedance of ear APs of 30 breast cancer patients and the corresponding skin impedance of ear APs of 30 healthy humans, and then we compared these changes in ear AP impedance in breast cancer patients and healthy individuals. PMID:26504483

  14. Superconducting surface impedance under radiofrequency field

    DOE PAGES

    Xiao, Binping P.; Reece, Charles E.; Kelley, Michael J.

    2013-04-26

    Based on BCS theory with moving Cooper pairs, the electron states distribution at 0K and the probability of electron occupation with finite temperature have been derived and applied to anomalous skin effect theory to obtain the surface impedance of a superconductor under radiofrequency (RF) field. We present the numerical results for Nb and compare these with representative RF field-dependent effective surface resistance measurements from a 1.5 GHz resonant structure.

  15. Prediction of lamb carcass composition by impedance spectroscopy.

    PubMed

    Altmann, M; Pliquett, U; Suess, R; von Borell, E

    2004-03-01

    The objective of this study was to compare impedance spectroscopy with resistance measurements at a single frequency (50 kHz) for the prediction of lamb carcass composition. The impedance spectrum is usually recorded by measuring the complex impedance at various frequencies (frequency domain); however, in this study, we also applied the faster and simpler measurement in the time domain (application of a current step and measurement of the voltage response). The study was carried out on 24 male, German Black-headed Mutton lambs with an average BW of 45 kg. Frequency- and time domain-based impedance measurements were collected at 20 min and 24 h postmortem with different electrode placements. Real and imaginary parts at various frequencies were calculated from the locus diagram. Left sides were dissected into lean, fat, and bone, and right sides were ground to determine actual carcass composition. Crude fat, crude protein, and moisture were chemically analyzed on ground samples. Frequency- and time domain-based measurements did not provide the same absolute impedance values; however, the high correlations (P < 0.001) between these methods for the "real parts" showed that they ranked individuals in the same order. Most of the time domain data correlated higher to carcass composition than did the frequency domain data. The real parts of impedance showed correlations between -0.37 (P > 0.05) and -0.74 (P < 0.001) to water, crude fat, lean, and fatty tissue, whereas the relations to CP were much lower (from 0.00 to -0.47, P < 0.05). Electrode placements at different locations did not substantially improve the correlations with carcass composition. The "imaginary parts" of impedance were not suitable for the prediction of carcass composition. The highest accuracy (R2 = 0.66) was reached for the estimation of crude fat percentage by a regression equation with the time domain-based impedance measured at 24 h postmortem. Furthermore, there was not a clear superiority of

  16. Ventilation mapping of chest using Focused Impedance Method (FIM)

    NASA Astrophysics Data System (ADS)

    Kadir, M. Abdul; Ferdous, Humayra; Baig, Tanvir Noor; Siddique-e-Rabbani, K.

    2010-04-01

    Focused Impedance Method (FIM) provides an opportunity for localized impedance measurement down to reasonable depths within the body using surface electrodes, and has a potential application in localized lung ventilation study. This however needs assessment of normal values for healthy individuals. In this study, localized ventilation maps in terms of electrical impedance in a matrix formation around the thorax, both from the front and the back, were obtained from two normal male subjects using a modified configuration of FIM. For this the focused impedance values at full inspiration and full expiration were measured and the percentage difference with respect to the latter was used. Some of the measured values would have artefacts due to movements of the heart and the diaphragm in the relevant anatomical positions which needs to be considered with due care in any interpretation.

  17. Bioelectrical impedance analysis for bovine milk: Preliminary results

    NASA Astrophysics Data System (ADS)

    Bertemes-Filho, P.; Valicheski, R.; Pereira, R. M.; Paterno, A. S.

    2010-04-01

    This work reports the investigation and analysis of bovine milk quality by using biological impedance measurements using electrical impedance spectroscopy (EIS). The samples were distinguished by a first chemical analysis using Fourier transform midinfrared spectroscopy (FTIR) and flow citometry. A set of milk samples (100ml each) obtained from 17 different cows in lactation with and without mastitis were analyzed with the proposed technique using EIS. The samples were adulterated by adding distilled water and hydrogen peroxide in a controlled manner. FTIR spectroscopy and flow cytometry were performed, and impedance measurements were made in a frequency range from 500Hz up to 1MHz with an implemented EIS system. The system's phase shift was compensated by measuring saline solutions. It was possible to show that the results obtained with the Bioelectrical Impedance Analysis (BIA) technique may detect changes in the milk caused by mastitis and the presence of water and hydrogen peroxide in the bovine milk.

  18. A comparison between handgrip strength, upper limb fat free mass by segmental bioelectrical impedance analysis (SBIA) and anthropometric measurements in young males

    NASA Astrophysics Data System (ADS)

    Gonzalez-Correa, C. H.; Caicedo-Eraso, J. C.; Varon-Serna, D. R.

    2013-04-01

    The mechanical function and size of a muscle may be closely linked. Handgrip strength (HGS) has been used as a predictor of functional performing. Anthropometric measurements have been made to estimate arm muscle area (AMA) and physical muscle mass volume of upper limb (ULMMV). Electrical volume estimation is possible by segmental BIA measurements of fat free mass (SBIA-FFM), mainly muscle-mass. Relationship among these variables is not well established. We aimed to determine if physical and electrical muscle mass estimations relate to each other and to what extent HGS is to be related to its size measured by both methods in normal or overweight young males. Regression analysis was used to determine association between these variables. Subjects showed a decreased HGS (65.5%), FFM, (85.5%) and AMA (74.5%). It was found an acceptable association between SBIA-FFM and AMA (r2 = 0.60) and poorer between physical and electrical volume (r2 = 0.55). However, a paired Student t-test and Bland and Altman plot showed that physical and electrical models were not interchangeable (pt<0.0001). HGS showed a very weak association with anthropometric (r2 = 0.07) and electrical (r2 = 0.192) ULMMV showing that muscle mass quantity does not mean muscle strength. Other factors influencing HGS like physical training or nutrition require more research.

  19. Electrochemical impedance spectroscopy system and methods for determining spatial locations of defects

    DOEpatents

    Glenn, David F.; Matthern, Gretchen E.; Propp, W. Alan; Glenn, Anne W.; Shaw, Peter G.

    2006-08-08

    A method and apparatus for determining spatial locations of defects in a material are described. The method includes providing a plurality of electrodes in contact with a material, applying a sinusoidal voltage to a select number of the electrodes at a predetermined frequency, determining gain and phase angle measurements at other of the electrodes in response to applying the sinusoidal voltage to the select number of electrodes, determining impedance values from the gain and phase angle measurements, computing an impedance spectrum for an area of the material from the determined impedance values, and comparing the computed impedance spectrum with a known impedance spectrum to identify spatial locations of defects in the material.

  20. Multi-frequency bioelectrical impedance: a comparison between the Cole-Cole modelling and Hanai equations with the classical impedance index approach.

    PubMed

    Deurenberg, P; Andreoli, A; de Lorenzo, A

    1996-01-01

    Total body water and extracellular water were measured by deuterium oxide and bromide dilution respectively in 23 healthy males and 25 healthy females. In addition, total body impedance was measured at 17 frequencies, ranging from 1 kHz to 1350 kHz. Modelling programs were used to extrapolate impedance values to frequency zero (extracellular resistance) and frequency infinity (total body water resistance). Impedance indexes (height2/Zf) were computed at all 17 frequencies. The estimation errors of extracellular resistance and total body water resistance were 1% and 3%, respectively. Impedance and impedance index at low frequency were correlated with extracellular water, independent of the amount of total body water. Total body water showed the greatest correlation with impedance and impedance index at high frequencies. Extrapolated impedance values did not show a higher correlation compared to measured values. Prediction formulas from the literature applied to fixed frequencies showed the best mean and individual predictions for both extracellular water and total body water. It is concluded that, at least in healthy individuals with normal body water distribution, modelling impedance data has no advantage over impedance values measured at fixed frequencies, probably due to estimation errors in the modelled data.

  1. Comparison of Two Acoustic Waveguide Methods for Determining Liner Impedance

    NASA Technical Reports Server (NTRS)

    Jones, Michael G.; Watson, Willie R.; Tracy, Maureen B.; Parrott, Tony L.

    2001-01-01

    Acoustic measurements taken in a flow impedance tube are used to assess the relative accuracy of two waveguide methods for impedance eduction in the presence of grazing flow. The aeroacoustic environment is assumed to contain forward and backward-traveling acoustic waves, consisting of multiple modes, and uniform mean flow. Both methods require a measurement of the complex acoustic pressure profile over the length of the test liner. The Single Mode Method assumes that the sound pressure level and phase decay-rates of a single progressive mode can be extracted from this measured complex acoustic pressure profile. No a priori assumptions are made in the Finite Element. Method regarding the modal or reflection content in the measured acoustic pressure profile. The integrity of each method is initially demonstrated by how well their no-flow impedances match those acquired in a normal incidence impedance tube. These tests were conducted using ceramic tubular and conventional perforate liners. Ceramic tubular liners were included because of their impedance insensitivity to mean flow effects. Conversely, the conventional perforate liner was included because its impedance is known to be sensitive to mean flow velocity effects. Excellent comparisons between impedance values educed with the two waveguide methods in the absence of mean flow and the corresponding values educed with the normal incident impedance tube were observed. The two methods are then compared for mean flow Mach numbers up to 0.5, and are shown to give consistent results for both types of test liners. The quality of the results indicates that the Single Mode Method should be used when the measured acoustic pressure profile is clearly dominated by a single progressive mode, and the Finite Element Method should be used for all other cases.

  2. Clinical implementation of electrical impedance tomography with hyperthermia.

    PubMed

    Moskowitz, M J; Ryan, T P; Paulsen, K D; Mitchell, S E

    1995-01-01

    We describe the use of electrical impedance tomography (EIT) for non-invasive thermal imaging in conjunction with a clinical treatment of a superficial scalp lesion utilizing a spiral microstrip antenna. This is our first reported use of EIT with a clinical hyperthermia treatment and perhaps the first world-wide. The thermal measurements recorded during treatment compare favourably with the images reconstructed from impedance data gathered during heating. A linear relation, measured in phantom material, between the change in temperature with the change in reconstructed impedance was assumed. The average discrepancy between the measured temperature changes with the temperatures reconstructed from the impedance changes was 1.4 degrees C, with the maximum being 8.9 degrees C. These preliminary data suggest that impedance changes can be measured during hyperthermia delivery and temperature estimates based on these observed changes are possible in the clinical setting. These findings also point to the complex, yet critical nature of the impedance versus temperature relationship for tissue in vivo. The reconstructed thermal images may provide complementary information about the overall thermal damage imposed during heating. Based on this initial clinical experience we feel that EIT has great potential as a viable clinical aid in imaging the temperature changes imposed during hyperthermia.

  3. Antenna pattern control using impedance surfaces

    NASA Technical Reports Server (NTRS)

    Balanis, Constantine A.; Liu, Kefeng

    1992-01-01

    During this research period, we have effectively transferred existing computer codes from CRAY supercomputer to work station based systems. The work station based version of our code preserved the accuracy of the numerical computations while giving a much better turn-around time than the CRAY supercomputer. Such a task relieved us of the heavy dependence of the supercomputer account budget and made codes developed in this research project more feasible for applications. The analysis of pyramidal horns with impedance surfaces was our major focus during this research period. Three different modeling algorithms in analyzing lossy impedance surfaces were investigated and compared with measured data. Through this investigation, we discovered that a hybrid Fourier transform technique, which uses the eigen mode in the stepped waveguide section and the Fourier transformed field distributions across the stepped discontinuities for lossy impedances coating, gives a better accuracy in analyzing lossy coatings. After a further refinement of the present technique, we will perform an accurate radiation pattern synthesis in the coming reporting period.

  4. Equivalent complex conductivities representing the effects of T-tubules and folded surface membranes on the electrical admittance and impedance of skeletal muscles measured by external-electrode method

    NASA Astrophysics Data System (ADS)

    Sekine, Katsuhisa

    2017-12-01

    In order to represent the effects of T-tubules and folded surface membranes on the electrical admittance and impedance of skeletal muscles measured by the external-electrode method, analytical relations for the equivalent complex conductivities of hypothetical smooth surface membranes were derived. In the relations, the effects of each tubule were represented by the admittance of a straight cable. The effects of the folding of a surface membrane were represented by the increased area of surface membranes. The equivalent complex conductivities were represented as summation of these effects, and the effects of the T-tubules were different between the transversal and longitudinal directions. The validity of the equivalent complex conductivities was supported by the results of finite-difference method (FDM) calculations made using three-dimensional models in which T-tubules and folded surface membranes were represented explicitly. FDM calculations using the equivalent complex conductivities suggested that the electrically inhomogeneous structure due to the existence of muscle cells with T-tubules was sufficient for explaining the experimental results previously obtained using the external-electrode method. Results of FDM calculations in which the structural changes caused by muscle contractions were taken into account were consistent with the reported experimental results.

  5. [Impedance between modiolus and different walls of scala tympani].

    PubMed

    Du, Qiang; Wang, Zhengmin

    2008-10-01

    To compare the impedance between the modiolus and the inner wall of scala tympani with that between the modiolus and the outer wall of scala tympani. The impedances between the modiolus and the inner wall of scala tympani and the impedance between the modiolus and the outer wall of scala tympani were measured, calculated and compared under different stimulating rates 0.1, 1.0, 10.0 kHz. The impedance between the modiolus and the inner wall of scala tympani is less than that between the modiolus and the outer wall of scala tympani (P < 0.05). To effectively stimulate the residual neurons in the spiral ganglion, the electrodes should be kept close to the inner wall of scale tympani.

  6. Digital synthetic impedance for application in vibration damping.

    PubMed

    Nečásek, J; Václavík, J; Marton, P

    2016-02-01

    In this work we present construction details of a precision, standalone, and compact digital synthetic impedance for application in the field of vibration damping. The presented device is based on an embedded ARM microcontroller with external AD and DA converters and a special analog front-end. The performance of the device is tested by comparing the actually synthesized impedance with several prescribed impedances and shows very good match. Fine-tuning ability of the device, which is crucial for the considered application, is also demonstrated and reaches as small step as 0.1% for the most complicated impedance structure and drops below the level of direct measurability with less complex structures. The real application in vibration damping is demonstrated on a simple and well understood case of a one-dimensional vibrating spring-mass system with piezoelectric actuator embedded as the interface between source of vibrations and vibrating mass.

  7. Digital synthetic impedance for application in vibration damping

    NASA Astrophysics Data System (ADS)

    Nečásek, J.; Václavík, J.; Marton, P.

    2016-02-01

    In this work we present construction details of a precision, standalone, and compact digital synthetic impedance for application in the field of vibration damping. The presented device is based on an embedded ARM microcontroller with external AD and DA converters and a special analog front-end. The performance of the device is tested by comparing the actually synthesized impedance with several prescribed impedances and shows very good match. Fine-tuning ability of the device, which is crucial for the considered application, is also demonstrated and reaches as small step as 0.1% for the most complicated impedance structure and drops below the level of direct measurability with less complex structures. The real application in vibration damping is demonstrated on a simple and well understood case of a one-dimensional vibrating spring-mass system with piezoelectric actuator embedded as the interface between source of vibrations and vibrating mass.

  8. Development of a wearable multi-frequency impedance cardiography device.

    PubMed

    Weyer, Sören; Menden, Tobias; Leicht, Lennart; Leonhardt, Steffen; Wartzek, Tobias

    2015-02-01

    Cardiovascular diseases as well as pulmonary oedema can be early diagnosed using vital signs and thoracic bio-impedance. By recording the electrocardiogram (ECG) and the impedance cardiogram (ICG), vital parameters are captured continuously. The aim of this study is the continuous monitoring of ECG and multi-frequency ICG by a mobile system. A mobile measuring system, based on 'low-power' ECG, ICG and an included radio transmission is described. Due to the high component integration, a board size of only 6.5 cm×5 cm could be realized. The measured data can be transmitted via Bluetooth and visualized on a portable monitor. By using energy-efficient hardware, the system can operate for up to 18 hs with a 3 V battery, continuously sending data via Bluetooth. Longer operating times can be realized by decreased transfer rates. The relative error of the impedance measurement was less than 1%. The ECG and ICG measurements allow an approximate calculation of the heart stroke volume. The ECG and the measured impedance showed a high correlation to commercial devices (r=0.83, p<0.05). In addition to commercial devices, the developed system allows a multi-frequency measurement of the thoracic impedance between 5-150 kHz.

  9. Anisotropic bioelectrical impedance determination of subcutaneous fat thickness

    NASA Astrophysics Data System (ADS)

    Hernández-Becerra, P. A. I.; Delgadillo-Holtfort, I.; Balleza-Ordaz, M.; Huerta-Franco, M. R.; Vargas-Luna, M.

    2014-11-01

    Preliminary results have shown that bioelectrical impedance measurements performed on different parts of the human body strongly depend upon the subcutaneous fat of the considered region. In this work, a method for the determination of subcutaneous fat thickness is explored. Within this method the measurement of the bioelectrical impedance response of the fat-muscle system, both along the direction defined by the muscle fibers and along the corresponding perpendicular direction, are performed. Measurements have been carried out on human female and male subjects of ages around 25 years old at the region of the biceps. Correlation has been performed with skinfold caliper measurements.

  10. Dependence of Impedance of Embedded Single Cells on Cellular Behaviour

    PubMed Central

    Cho, Sungbo; Castellarnau, Marc; Samitier, Josep; Thielecke, Hagen

    2008-01-01

    Non-invasive single cell analyses are increasingly required for the medical diagnostics of test substances or the development of drugs and therapies on the single cell level. For the non-invasive characterisation of cells, impedance spectroscopy which provides the frequency dependent electrical properties has been used. Recently, microfludic systems have been investigated to manipulate the single cells and to characterise the electrical properties of embedded cells. In this article, the impedance of partially embedded single cells dependent on the cellular behaviour was investigated by using the microcapillary. An analytical equation was derived to relate the impedance of embedded cells with respect to the morphological and physiological change of extracellular interface. The capillary system with impedance measurement showed a feasibility to monitor the impedance change of embedded single cells caused by morphological and physiological change of cell during the addition of DMSO. By fitting the derived equation to the measured impedance of cell embedded at different negative pressure levels, it was able to extrapolate the equivalent gap and gap conductivity between the cell and capillary wall representing the cellular behaviour. PMID:27879760

  11. Dependence of Impedance of Embedded Single Cells on Cellular Behaviour.

    PubMed

    Cho, Sungbo; Castellarnau, Marc; Samitier, Josep; Thielecke, Hagen

    2008-02-21

    Non-invasive single cell analyses are increasingly required for the medicaldiagnostics of test substances or the development of drugs and therapies on the single celllevel. For the non-invasive characterisation of cells, impedance spectroscopy whichprovides the frequency dependent electrical properties has been used. Recently,microfludic systems have been investigated to manipulate the single cells and tocharacterise the electrical properties of embedded cells. In this article, the impedance ofpartially embedded single cells dependent on the cellular behaviour was investigated byusing the microcapillary. An analytical equation was derived to relate the impedance ofembedded cells with respect to the morphological and physiological change ofextracellular interface. The capillary system with impedance measurement showed afeasibility to monitor the impedance change of embedded single cells caused bymorphological and physiological change of cell during the addition of DMSO. By fittingthe derived equation to the measured impedance of cell embedded at different negativepressure levels, it was able to extrapolate the equivalent gap and gap conductivity betweenthe cell and capillary wall representing the cellular behaviour.

  12. Implementation and Validation of an Impedance Eduction Technique

    NASA Technical Reports Server (NTRS)

    Watson, Willie R.; Jones, Michael G.; Gerhold, Carl H.

    2011-01-01

    Implementation of a pressure gradient method of impedance eduction in two NASA Langley flow ducts is described. The Grazing Flow Impedance Tube only supports plane-wave sources, while the Curved Duct Test Rig supports sources that contain higher-order modes. Multiple exercises are used to validate this new impedance eduction method. First, synthesized data for a hard wall insert and a conventional liner mounted in the Grazing Flow Impedance Tube are used as input to the two impedance eduction methods, the pressure gradient method and a previously validated wall pressure method. Comparisons between the two results are excellent. Next, data measured in the Grazing Flow Impedance Tube are used as input to both methods. Results from the two methods compare quite favorably for sufficiently low Mach numbers but this comparison degrades at Mach 0.5, especially when the hard wall insert is used. Finally, data measured with a hard wall insert mounted in the Curved Duct Test Rig are used as input to the pressure gradient method. Significant deviation from the known solution is observed, which is believed to be largely due to 3-D effects in this flow duct. Potential solutions to this issue are currently being explored.

  13. BPM Design and Impedance Considerations for a Rotatable Collimator for the LHC Collimation Upgrade

    SciTech Connect

    Smith, Jeffrey Claiborne; /SLAC; Keller, Lewis

    2010-08-26

    The Phase II upgrade to the LHC collimation system calls for complementing the 30 high robust Phase I graphite secondary collimators with 30 high Z Phase II collimators. This paper reports on BPM and impedance considerations and measurements of the integrated BPMs in the prototype rotatable collimator to be installed in the Super Proton Synchrotron (SPS) at CERN. The BPMs are necessary to align the jaws with the beam. Without careful design the beam impedance can result in unacceptable heating of the chamber wall or beam instabilities. The impedance measurements involve utilizing both a single displaced wire and two wiresmore » excited in opposite phase to disentangle the driving and detuning transverse impedances. Trapped mode resonances and longitudinal impedance are to also be measured and compared with simulations. These measurements, when completed, will demonstrate the device is fully operational and has the impedance characteristics and BPM performance acceptable for installation in the SPS.« less

  14. Broadband Planar 5:1 Impedence Transformer

    NASA Technical Reports Server (NTRS)

    Ehsan, Negar; Hsieh, Wen-Ting; Moseley, Samuel H.; Wollack, Edward J.

    2015-01-01

    This paper presents a broadband Guanella-type planar impedance transformer that transforms so 50 omega to 10 omega with a 10 dB bandwidth of 1-14GHz. The transformer is designed on a flexible 50 micrometer thick polyimide substrate in microstrip and parallel-plate transmission line topologies, and is Inspired by the traditional 4:1 Guanella transformer. Back-to-back transformers were designed and fabricated for characterization in a 50 omega system. Simulated and measured results are in excellent agreement.

  15. Method for conducting nonlinear electrochemical impedance spectroscopy

    DOEpatents

    Adler, Stuart B.; Wilson, Jamie R.; Huff, Shawn L.; Schwartz, Daniel T.

    2015-06-02

    A method for conducting nonlinear electrochemical impedance spectroscopy. The method includes quantifying the nonlinear response of an electrochemical system by measuring higher-order current or voltage harmonics generated by moderate-amplitude sinusoidal current or voltage perturbations. The method involves acquisition of the response signal followed by time apodization and fast Fourier transformation of the data into the frequency domain, where the magnitude and phase of each harmonic signal can be readily quantified. The method can be implemented on a computer as a software program.

  16. Electrochemical Impedance Of Inorganic-Zinc-Coated Steel

    NASA Technical Reports Server (NTRS)

    Macdowell, Louis G.

    1992-01-01

    Report describes preliminary experiments to evaluate both direct-current and alternating-current electrochemical impedance measurements as candidate techniques for use in accelerated corrosion testing of mild-steel panels coated with inorganic zinc-rich primers and exposed to seaside air. Basic idea behind experiments to compare electrochemical impedance measurements with anticorrosion performances of coating materials to determine whether measurements can be used to predict performances. Part of continuing program to identify anticorrosion coating materials protecting steel panels adequately for as long as 5 years and beyond.

  17. Optimization and Control of Acoustic Liner Impedance with Bias Flow

    NASA Technical Reports Server (NTRS)

    Wood, Houston; Follet, Jesse

    2000-01-01

    Because communities are impacted by steady increases in aircraft traffic, aircraft noise continues to be a growing problem for the growth of commercial aviation. Research has focused on improving the design of specific high noise source areas of aircraft and on noise control measures to alleviate noise radiated from aircraft to the surrounding environment. Engine duct liners have long been a principal means of attenuating engine noise. The ability to control in-situ the acoustic impedance of a liner would provide a valuable tool to improve the performance of liners. The acoustic impedance of a liner is directly related to the sound absorption qualities of that liner. Increased attenuation rates, the ability to change liner acoustic impedance to match various operating conditions, or the ability to tune a liner to more precisely match design impedance represent some ways that in-situ impedance control could be useful. With this in mind, the research to be investigated will focus on improvements in the ability to control liner impedance using a mean flow through the liner which is referred to as bias flow.

  18. Development of the algorithm of measurement data and tomographic section reconstruction results processing for evaluating the respiratory activity of the lungs using the multi-angle electric impedance tomography

    NASA Astrophysics Data System (ADS)

    Aleksanyan, Grayr; Shcherbakov, Ivan; Kucher, Artem; Sulyz, Andrew

    2018-04-01

    Continuous monitoring of the patient's breathing by the method of multi-angle electric impedance tomography allows to obtain images of conduction change in the chest cavity during the monitoring. Direct analysis of images is difficult due to the large amount of information and low resolution images obtained by multi-angle electrical impedance tomography. This work presents a method for obtaining a graph of respiratory activity of the lungs based on the results of continuous lung monitoring using the multi-angle electrical impedance tomography method. The method makes it possible to obtain a graph of the respiratory activity of the left and right lungs separately, as well as a summary graph, to which it is possible to apply methods of processing the results of spirography.

  19. Comparison of three rf plasma impedance monitors on a high phase angle planar inductively coupled plasma source

    NASA Astrophysics Data System (ADS)

    Uchiyama, H.; Watanabe, M.; Shaw, D. M.; Bahia, J. E.; Collins, G. J.

    1999-10-01

    Accurate measurement of plasma source impedance is important for verification of plasma circuit models, as well as for plasma process characterization and endpoint detection. Most impedance measurement techniques depend in some manner on the cosine of the phase angle to determine the impedance of the plasma load. Inductively coupled plasmas are generally highly inductive, with the phase angle between the applied rf voltage and the rf current in the range of 88 to near 90 degrees. A small measurement error in this phase angle range results in a large error in the calculated cosine of the angle, introducing large impedance measurement variations. In this work, we have compared the measured impedance of a planar inductively coupled plasma using three commercial plasma impedance monitors (ENI V/I probe, Advanced Energy RFZ60 and Advanced Energy Z-Scan). The plasma impedance is independently verified using a specially designed match network and a calibrated load, representing the plasma, to provide a measurement standard.

  20. Impedance-matched Marx generators

    NASA Astrophysics Data System (ADS)

    Stygar, W. A.; LeChien, K. R.; Mazarakis, M. G.; Savage, M. E.; Stoltzfus, B. S.; Austin, K. N.; Breden, E. W.; Cuneo, M. E.; Hutsel, B. T.; Lewis, S. A.; McKee, G. R.; Moore, J. K.; Mulville, T. D.; Muron, D. J.; Reisman, D. B.; Sceiford, M. E.; Wisher, M. L.

    2017-04-01

    We have conceived a new class of prime-power sources for pulsed-power accelerators: impedance-matched Marx generators (IMGs). The fundamental building block of an IMG is a brick, which consists of two capacitors connected electrically in series with a single switch. An IMG comprises a single stage or several stages distributed axially and connected in series. Each stage is powered by a single brick or several bricks distributed azimuthally within the stage and connected in parallel. The stages of a multistage IMG drive an impedance-matched coaxial transmission line with a conical center conductor. When the stages are triggered sequentially to launch a coherent traveling wave along the coaxial line, the IMG achieves electromagnetic-power amplification by triggered emission of radiation. Hence a multistage IMG is a pulsed-power analogue of a laser. To illustrate the IMG approach to prime power, we have developed conceptual designs of two ten-stage IMGs with L C time constants on the order of 100 ns. One design includes 20 bricks per stage, and delivers a peak electrical power of 1.05 TW to a matched-impedance 1.22 -Ω load. The design generates 113 kV per stage and has a maximum energy efficiency of 89%. The other design includes a single brick per stage, delivers 68 GW to a matched-impedance 19 -Ω load, generates 113 kV per stage, and has a maximum energy efficiency of 90%. For a given electrical-power-output time history, an IMG is less expensive and slightly more efficient than a linear transformer driver, since an IMG does not use ferromagnetic cores.

  1. TRANSVERSE ELECTRIC IMPEDANCE OF THE SQUID GIANT AXON

    PubMed Central

    Curtis, Howard J.; Cole, Kenneth S.

    1938-01-01

    The impedance of the excised giant axon from hindmost stellar nerve of Loligo pealii has been measured over the frequency range from 1 to 2500 kilocycles per second. The measurements have been made with the current flow perpendicular to the axis of the axon to permit a relatively simple analysis of the data. It has been found that the axon membrane has a polarization impedance with an average phase angle of 76° and an average capacity of 1.1µf./cm2 at 1 kilocycle. The direct current resistance of the membrane could not be measured, but was greater than 3 ohm cm.2 and the average internal specific resistance was four times that of sea water. There was no detectable change in the membrane impedance when the axon lost excitability, but some time later it decreased to zero. PMID:19873081

  2. Impedance analysis of acupuncture points and pathways

    NASA Astrophysics Data System (ADS)

    Teplan, Michal; Kukučka, Marek; Ondrejkovičová, Alena

    2011-12-01

    Investigation of impedance characteristics of acupuncture points from acoustic to radio frequency range is addressed. Discernment and localization of acupuncture points in initial single subject study was unsuccessfully attempted by impedance map technique. Vector impedance analyses determined possible resonant zones in MHz region.

  3. 21 CFR 870.2770 - Impedance plethysmograph.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Impedance plethysmograph. 870.2770 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2770 Impedance plethysmograph. (a) Identification. An impedance plethysmograph is a device used to estimate peripheral blood...

  4. 21 CFR 870.2750 - Impedance phlebograph.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Impedance phlebograph. 870.2750 Section 870.2750...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2750 Impedance phlebograph. (a) Identification. An impedance phlebograph is a device used to provide a visual display of the...

  5. Efficient Simultaneous Reconstruction of Time-Varying Images and Electrode Contact Impedances in Electrical Impedance Tomography.

    PubMed

    Boverman, Gregory; Isaacson, David; Newell, Jonathan C; Saulnier, Gary J; Kao, Tzu-Jen; Amm, Bruce C; Wang, Xin; Davenport, David M; Chong, David H; Sahni, Rakesh; Ashe, Jeffrey M

    2017-04-01

    In electrical impedance tomography (EIT), we apply patterns of currents on a set of electrodes at the external boundary of an object, measure the resulting potentials at the electrodes, and, given the aggregate dataset, reconstruct the complex conductivity and permittivity within the object. It is possible to maximize sensitivity to internal conductivity changes by simultaneously applying currents and measuring potentials on all electrodes but this approach also maximizes sensitivity to changes in impedance at the interface. We have, therefore, developed algorithms to assess contact impedance changes at the interface as well as to efficiently and simultaneously reconstruct internal conductivity/permittivity changes within the body. We use simple linear algebraic manipulations, the generalized singular value decomposition, and a dual-mesh finite-element-based framework to reconstruct images in real time. We are also able to efficiently compute the linearized reconstruction for a wide range of regularization parameters and to compute both the generalized cross-validation parameter as well as the L-curve, objective approaches to determining the optimal regularization parameter, in a similarly efficient manner. Results are shown using data from a normal subject and from a clinical intensive care unit patient, both acquired with the GE GENESIS prototype EIT system, demonstrating significantly reduced boundary artifacts due to electrode drift and motion artifact.

  6. Uncertainty Analysis of the Grazing Flow Impedance Tube

    NASA Technical Reports Server (NTRS)

    Brown, Martha C.; Jones, Michael G.; Watson, Willie R.

    2012-01-01

    This paper outlines a methodology to identify the measurement uncertainty of NASA Langley s Grazing Flow Impedance Tube (GFIT) over its operating range, and to identify the parameters that most significantly contribute to the acoustic impedance prediction. Two acoustic liners are used for this study. The first is a single-layer, perforate-over-honeycomb liner that is nonlinear with respect to sound pressure level. The second consists of a wire-mesh facesheet and a honeycomb core, and is linear with respect to sound pressure level. These liners allow for evaluation of the effects of measurement uncertainty on impedances educed with linear and nonlinear liners. In general, the measurement uncertainty is observed to be larger for the nonlinear liners, with the largest uncertainty occurring near anti-resonance. A sensitivity analysis of the aerodynamic parameters (Mach number, static temperature, and static pressure) used in the impedance eduction process is also conducted using a Monte-Carlo approach. This sensitivity analysis demonstrates that the impedance eduction process is virtually insensitive to each of these parameters.

  7. Application of plant impedance for diagnosing plant disease

    NASA Astrophysics Data System (ADS)

    Xu, Huirong; Jiang, Xuesong; Zhu, Shengpan; Ying, Yibin

    2006-10-01

    Biological cells have components acting as electrical elements that maintain the health of the cell by regulation of the electrical charge content. Plant impedance is decided by the state of plant physiology and pathology. Plant physiology and pathology can be studies by measuring plant impedance. The effect of Cucumber Mosaic Virus red bean isolate (CMV-RB) on electrical resistance of tomato leaves was studied by the method of impedance measurement. It was found that the value of resistance of tomato leaves infected with CMV-RB was smaller than that in sound plant leaves. This decrease of impedances in leaf tissue was occurred with increased severity of disease. The decrease of resistance of tomato leaves infected with CMV-RB could be detected by electrical resistance detecting within 4 days after inoculation even though significant visible differences between the control and the infected plants were not noted, so that the technique for measurement of tomato leaf tissue impedance is a rapid, clever, simple method on diagnosis of plant disease.

  8. Characterisation of CFRP adhesive bonds by electromechanical impedance

    NASA Astrophysics Data System (ADS)

    Malinowski, Pawel H.; Wandowski, Tomasz; Ostachowicz, Wieslaw M.

    2014-03-01

    In aircraft industry the Carbon Fiber Reinforced Polymer (CFRP) elements are joint using rivets and adhesive bonding. The reliability of the bonding limits the use of adhesive bonding for primary aircraft structures, therefore it is important to assess the bond quality. The performance of adhesive bonds depends on the physico-chemical properties of the adhered surfaces. The contamination leading to weak bonds may have various origin and be caused by moisture, release agent, hydraulic fluid, fuel, poor curing of adhesive and so on. In this research three different causes of possible weak bonds were selected for the investigation: 1. Weak bond due to release agent contamination, 2. Weak bond due to moisture contamination, 3. Weak bond due to poor curing of the adhesive. In order to assess the bond quality electromechanical impedance (EMI) technique was selected and investigation was focused on the influence of bond quality on electrical impedance of piezoelectric transducer. The piezoelectric transducer was mounted at the middle of each sample surface. Measurements were conducted using HIOKI Impedance Analyzer IM3570. Using the impedance analyzer the electrical parameters were measured for wide frequency band. Due to piezoelectric effect the electrical response of a piezoelectric transducer is related to mechanical response of the sample to which the transducers is attached. The impedance spectra were investigated in order to find indication of the weak bonds. These spectra were compared with measurements for reference sample using indexes proposed in order to assess the bond quality.

  9. Finger impedance evaluation by means of hand exoskeleton.

    PubMed

    Fiorilla, Angelo Emanuele; Nori, Francesco; Masia, Lorenzo; Sandini, Giulio

    2011-12-01

    Modulation of arm mechanical impedance is a fundamental aspect for interaction with the external environment and its regulation is essential for stability preservation during manipulation. Even though past research on human arm movements has suggested that models of human finger impedance would benefit the study of neural control mechanisms and the design of novel hand prostheses, relatively few studies have focused on finger and hand impedance. This article touches on the two main aspects of this research topic: first it introduces a mechanical refinement of a device that can be used to effectively measure finger impedance during manipulation tasks; then, it describes a pilot study aimed at identifying the inertia of the finger and the viscous and elastic properties of finger muscles. The proposed wearable exoskeleton, which has been designed to measure finger posture and impedance modulation while leaving the palm free, is capable of applying fast displacements while monitoring the interaction forces between the human finger and the robotic links. Moreover, due to the relatively small inertia of the fingers, it allows us to meet some stringent specifications, performing relatively large displacements (~45°) before the stretch reflex intervenes (~25 ms). The results of measurements on five subjects show that inertia, damping, and stiffness can be effectively identified and that the parameters obtained are comparable with values from previous studies.

  10. Utilization of bone impedance for age estimation in postmortem cases.

    PubMed

    Ishikawa, Noboru; Suganami, Hideki; Nishida, Atsushi; Miyamori, Daisuke; Kakiuchi, Yasuhiro; Yamada, Naotake; Wook-Cheol, Kim; Kubo, Toshikazu; Ikegaya, Hiroshi

    2015-11-01

    In the field of Forensic Medicine the number of unidentified cadavers has increased due to natural disasters and international terrorism. The age estimation is very important for identification of the victims. The degree of sagittal closure is one of such age estimation methods. However it is not widely accepted as a reliable method for age estimation. In this study, we have examined whether measuring impedance value (z-values) of the sagittal suture of the skull is related to the age in men and women and discussed the possibility to use bone impedance for age estimation. Bone impedance values increased with aging and decreased after the age of 64.5. Then we compared age estimation through the conventional visual method and the proposed bone impedance measurement technique. It is suggested that the bone impedance measuring technique may be of value to forensic science as a method of age estimation. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  11. Smart Multi-Frequency Bioelectrical Impedance Spectrometer for BIA and BIVA Applications.

    PubMed

    Harder, Rene; Diedrich, Andre; Whitfield, Jonathan S; Buchowski, Macie S; Pietsch, John B; Baudenbacher, Franz J

    2016-08-01

    Bioelectrical impedance analysis (BIA) is a noninvasive and commonly used method for the assessment of body composition including body water. We designed a small, portable and wireless multi-frequency impedance spectrometer based on the 12 bit impedance network analyzer AD5933 and a precision wide-band constant current source for tetrapolar whole body impedance measurements. The impedance spectrometer communicates via Bluetooth with mobile devices (smart phone or tablet computer) that provide user interface for patient management and data visualization. The export of patient measurement results into a clinical research database facilitates the aggregation of bioelectrical impedance analysis and biolectrical impedance vector analysis (BIVA) data across multiple subjects and/or studies. The performance of the spectrometer was evaluated using a passive tissue equivalent circuit model as well as a comparison of body composition changes assessed with bioelectrical impedance and dual-energy X-ray absorptiometry (DXA) in healthy volunteers. Our results show an absolute error of 1% for resistance and 5% for reactance measurements in the frequency range of 3 kHz to 150 kHz. A linear regression of BIA and DXA fat mass estimations showed a strong correlation (r(2)=0.985) between measures with a maximum absolute error of 6.5%. The simplicity of BIA measurements, a cost effective design and the simple visual representation of impedance data enables patients to compare and determine body composition during the time course of a specific treatment plan in a clinical or home environment.

  12. Effects of tissue impedance on heat generation during RF delivery with the Thermage system

    NASA Astrophysics Data System (ADS)

    Tomkoria, Sara; Pope, Karl

    2005-04-01

    The Thermage ThermaCool TC system is a non-ablative RF device designed to promote tissue tightening and contouring. The system delivers RF energy to a target area under the skin, with volumetric tissue heating in that area. While the amount of energy delivered to a patient can be controlled by ThermaCool system settings, the distribution of energy to the treatment area and underlying layers is variable from individual to individual due to differences in body composition. The present study investigated how local tissue impedance affects the amount of discomfort experienced by patients during RF energy delivery. Discomfort results from heat generation in the treatment area. By using features of the ThermaCool TC System, local impedance (impedance of the treatment area), bulk impedance (impedance of the underlying tissue layers), and total impedance (the sum of local and bulk impedance) were measured for 35 patients. For each patient, impedance measurements were compared to discomfort levels expressed during treatment. Analysis of whole body, local, and bulk impedance values indicate that the percent of total body impedance in the local treatment area contributes to discomfort levels expressed by patients during treatment.

  13. A high frequency electromagnetic impedance imaging system

    SciTech Connect

    Tseng, Hung-Wen; Lee, Ki Ha; Becker, Alex

    2003-01-15

    Non-invasive, high resolution geophysical mapping of the shallow subsurface is necessary for delineation of buried hazardous wastes, detecting unexploded ordinance, verifying and monitoring of containment or moisture contents, and other environmental applications. Electromagnetic (EM) techniques can be used for this purpose since electrical conductivity and dielectric permittivity are representative of the subsurface media. Measurements in the EM frequency band between 1 and 100 MHz are very important for such applications, because the induction number of many targets is small and the ability to determine the subsurface distribution of both electrical properties is required. Earlier workers were successful in developing systemsmore » for detecting anomalous areas, but quantitative interpretation of the data was difficult. Accurate measurements are necessary, but difficult to achieve for high-resolution imaging of the subsurface. We are developing a broadband non-invasive method for accurately mapping the electrical conductivity and dielectric permittivity of the shallow subsurface using an EM impedance approach similar to the MT exploration technique. Electric and magnetic sensors were tested to ensure that stray EM scattering is minimized and the quality of the data collected with the high-frequency impedance (HFI) system is good enough to allow high-resolution, multi-dimensional imaging of hidden targets. Additional efforts are being made to modify and further develop existing sensors and transmitters to improve the imaging capability and data acquisition efficiency.« less

  14. Determination of Peukert's Constant Using Impedance Spectroscopy: Application to Supercapacitors.

    PubMed

    Mills, Edmund Martin; Kim, Sangtae

    2016-12-15

    Peukert's equation is widely used to model the rate dependence of battery capacity, and has recently attracted attention for application to supercapacitors. Here we present a newly developed method to readily determine Peukert's constant using impedance spectroscopy. Impedance spectroscopy is ideal for this purpose as it has the capability of probing electrical performance of a device over a wide range of time-scales within a single measurement. We demonstrate that the new method yields consistent results with conventional galvanostatic measurements through applying it to commercially available supercapacitors. Additionally, the novel method is much simpler and more precise, making it an attractive alternative for the determination of Peukert's constant.

  15. A Wireless Multi-Sensor Dielectric Impedance Spectroscopy Platform

    PubMed Central

    Ghaffari, Seyed Alireza; Caron, William-O.; Loubier, Mathilde; Rioux, Maxime; Viens, Jeff; Gosselin, Benoit; Messaddeq, Younes

    2015-01-01

    This paper describes the development of a low-cost, miniaturized, multiplexed, and connected platform for dielectric impedance spectroscopy (DIS), designed for in situ measurements and adapted to wireless network architectures. The platform has been tested and used as a DIS sensor node on ZigBee mesh and was able to interface up to three DIS sensors at the same time and relay the information through the network for data analysis and storage. The system is built from low-cost commercial microelectronics components, performs dielectric spectroscopy ranging from 5 kHz to 100 kHz, and benefits from an on-the-fly calibration system that makes sensor calibration easy. The paper describes the microelectronics design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the testing of the platform for in situ dielectric impedance spectroscopy applications pertaining to fertilizer sensing, water quality sensing, and touch sensing. PMID:26393587

  16. From impedance theory to needle electrode guidance in tissue

    NASA Astrophysics Data System (ADS)

    Kalvøy, Håvard; Høyum, Per; Grimnes, Sverre; Martinsen, Ørjan G.

    2010-04-01

    Fast access to blood vessels or other tissues/organs can be crucial in clinical or acute medical treatment. We have developed a method for needle guidance for use in different types of applications. The feasibility of an automatic application for fast access to blood vessels during acute cardiac arrest, based on this method, has been evaluated. Suited electrode setups were found by development of needle electrode models used in simulation and sensitivity analyses. In vitro measurements were done both to determine the fundamental properties of the electrodes for use in the models and to confirm the simulation results. Development of algorithms for tissue characterization and differentiation was based on in vivo impedance measurement in porcine models and confirmed in human tissue in vivo. Feasibility was proven by application prototyping and impedance data presented as invasive Electrical Impedance Tomography (iEIT). Our conclusion is that this method can be utilized in a wide range of clinical applications.

  17. Investigation of an Anomaly Observed in Impedance Eduction Techniques

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.; Parrott, T. L.

    2008-01-01

    An intensive investigation into the cause of anomalous behavior commonly observed in impedance eduction techniques is performed. The investigation consists of grid refinement studies, detailed evaluation of results at and near anti-resonance frequencies, comparisons of different model results with synthesized and measured data, assessment or optimization techniques, and evaluation or boundary condition effects. Results show that the root cause of the anomalous behavior is the sensitivity of the educed impedance to small errors in the measured termination resistance at frequencies near anti-resonance or cut-on of a higher-order mode. Evidence is presented to show that the common usage of an anechoic, plane wave termination boundary condition in ducts where the "true" termination is reflective may act as a trigger for these anomalies. Replacing the exit impedance boundary condition by an exit pressure condition is shown to reduce the anomalous results.

  18. Low-frequency quadrupole impedance of undulators and wigglers

    DOE PAGES

    Blednykh, A.; Bassi, G.; Hidaka, Y.; ...

    2016-10-25

    An analytical expression of the low-frequency quadrupole impedance for undulators and wigglers is derived and benchmarked against beam-based impedance measurements done at the 3 GeV NSLS-II storage ring. The adopted theoretical model, valid for an arbitrary number of electromagnetic layers with parallel geometry, allows to calculate the quadrupole impedance for arbitrary values of the magnetic permeability μ r. Here, in the comparison of the analytical results with the measurements for variable magnet gaps, two limit cases of the permeability have been studied: the case of perfect magnets (μ r → ∞), and the case in which the magnets are fullymore » saturated (μ r = 1).« less

  19. Broadband spectroscopy of dynamic impedances with short chirp pulses.

    PubMed

    Min, M; Land, R; Paavle, T; Parve, T; Annus, P; Trebbels, D

    2011-07-01

    An impedance spectrum of dynamic systems is time dependent. Fast impedance changes take place, for example, in high throughput microfluidic devices and in operating cardiovascular systems. Measurements must be as short as possible to avoid significant impedance changes during the spectrum analysis, and as long as possible for enlarging the excitation energy and obtaining a better signal-to-noise ratio (SNR). The authors propose to use specific short chirp pulses for excitation. Thanks to the specific properties of the chirp function, it is possible to meet the needs for a spectrum bandwidth, measurement time and SNR so that the most accurate impedance spectrogram can be obtained. The chirp wave excitation can include thousands of cycles when the impedance changes slowly, but in the case of very high speed changes it can be shorter than a single cycle, preserving the same excitation bandwidth. For example, a 100 kHz bandwidth can be covered by the chirp pulse with durations from 10 µs to 1 s; only its excitation energy differs also 10(5) times. After discussing theoretical short chirp properties in detail, the authors show how to generate short chirps in the microsecond range with a bandwidth up to a few MHz by using digital synthesis architectures developed inside a low-cost standard field programmable gate array.

  20. Temperature dependence of acoustic impedance for specific fluorocarbon liquids

    NASA Astrophysics Data System (ADS)

    Marsh, Jon N.; Hall, Christopher S.; Wickline, Samuel A.; Lanza, Gregory M.

    2002-12-01

    Recent studies by our group have demonstrated the efficacy of perfluorocarbon liquid nanoparticles for enhancing the reflectivity of tissuelike surfaces to which they are bound. The magnitude of this enhancement depends in large part on the difference in impedances of the perfluorocarbon, the bound substrate, and the propagating medium. The impedance varies directly with temperature because both the speed of sound and the mass density of perfluorocarbon liquids are highly temperature dependent. However, there are relatively little data in the literature pertaining to the temperature dependence of the acoustic impedance of these compounds. In this study, the speed of sound and density of seven different fluorocarbon liquids were measured at specific temperatures between 20 °C and 45 °C. All of the samples demonstrated negative, linear dependencies on temperature for both speed of sound and density and, consequently, for the acoustic impedance. The slope of sound speed was greatest for perfluorohexane (-278+/-1.5 cm/s-°C) and lowest for perfluorodichlorooctane (-222+/-0.9 cm/s-°C). Of the compounds measured, perfluorohexane exhibited the lowest acoustic impedance at all temperatures, and perfluorodecalin the highest at all temperatures. Computations from a simple transmission-line model used to predict reflectivity enhancement from surface-bound nanoparticles are discussed in light of these results.

  1. Electrochemical impedance spectroscopy of supercapacitors: A novel analysis approach using evolutionary programming

    NASA Astrophysics Data System (ADS)

    Oz, Alon; Hershkovitz, Shany; Tsur, Yoed

    2014-11-01

    In this contribution we present a novel approach to analyze impedance spectroscopy measurements of supercapacitors. Transforming the impedance data into frequency-dependent capacitance allows us to use Impedance Spectroscopy Genetic Programming (ISGP) in order to find the distribution function of relaxation times (DFRT) of the processes taking place in the tested device. Synthetic data was generated in order to demonstrate this technique and a model for supercapacitor ageing process has been obtained.

  2. Bilateral Impedance Control For Telemanipulators

    NASA Technical Reports Server (NTRS)

    Moore, Christopher L.

    1993-01-01

    Telemanipulator system includes master robot manipulated by human operator, and slave robot performing tasks at remote location. Two robots electronically coupled so slave robot moves in response to commands from master robot. Teleoperation greatly enhanced if forces acting on slave robot fed back to operator, giving operator feeling he or she manipulates remote environment directly. Main advantage of bilateral impedance control: enables arbitrary specification of desired performance characteristics for telemanipulator system. Relationship between force and position modulated at both ends of system to suit requirements of task.

  3. Effect of Intravenous Infusion Solutions on Bioelectrical Impedance Spectroscopy.

    PubMed

    Yap, Jason; Rafii, Mahroukh; Azcue, Maria; Pencharz, Paul

    2017-05-01

    Bioelectrical impedance (BIA) is often used to measure body fluid spaces and thereby body composition. However, in acute animal studies, we found that impedance was driven by the saline content of intravenous (IV) fluids and not by the volume. The aim of the study was to investigate the effect of 3 different fluids acutely administered on the change in impedance, specifically resistance (R). Nine healthy adults participated in 3 treatment (0.9% saline, 5% dextrose, and a mixture of 0.3% saline + 3.3% dextrose) experiments on nonconsecutive days. They all received 1 L of one of the treatments intravenously over a 1-hour period. Repeated BIA measurements were performed prior to IV infusion and then every 5 minutes for the 1-hour infusion period, plus 3 more measurements up to 15 minutes after the completion of the infusion. The change in R in the 0.9% saline infusion experiment was significantly lower than that of the glucose and mixture treatment ( P < .001). Bioelectrical impedance spectroscopy and BIA measure salt rather than the volume changes over the infusion period. Hence, in patients receiving IV fluids, BIA of any kind (single frequency or multifrequency) cannot be used to measure body fluid spaces or body composition.

  4. Damage Assessment of Aerospace Structural Components by Impedance Based Health Monitoring

    NASA Technical Reports Server (NTRS)

    Gyekenyesi, Andrew L.; Martin, Richard E.; Sawicki, Jerzy T.; Baaklini, George Y.

    2005-01-01

    This paper addresses recent efforts at the NASA Glenn Research Center at Lewis Field relating to the set-up and assessment of electro-mechanical (E/M) impedance based structural health monitoring. The overall aim is the application of the impedance based technique to aeronautic and space based structural components. As initial steps, a laboratory was created, software written, and experiments conducted on aluminum plates in undamaged and damaged states. A simulated crack, in the form of a narrow notch at various locations, was analyzed using piezoelectric-ceramic (PZT: lead, zirconate, titarate) patches as impedance measuring transducers. Descriptions of the impedance quantifying hardware and software are provided as well as experimental results. In summary, an impedance based health monitoring system was assembled and tested. The preliminary data showed that the impedance based technique was successful in recognizing the damage state of notched aluminum plates.

  5. Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation.

    PubMed

    Cao, Hong; Tungjitkusolmun, Supan; Choy, Young Bin; Tsai, Jang-Zern; Vorperian, Vicken R; Webster, John G

    2002-03-01

    During radio-frequency (RF) cardiac catheter ablation, there is little information to estimate the contact between the catheter tip electrode and endocardium because only the metal electrode shows up under fluoroscopy. We present a method that utilizes the electrical impedance between the catheter electrode and the dispersive electrode to predict the catheter tip electrode insertion depth into the endocardium. Since the resistivity of blood differs from the resistivity of the endocardium, the impedance increases as the catheter tip lodges deeper in the endocardium. In vitro measurements yielded the impedance-depth relations at 1, 10, 100, and 500 kHz. We predict the depth by spline curve interpolation using the obtained calibration curve. This impedance method gives reasonably accurate predicted depth. We also evaluated alternative methods, such as impedance difference and impedance ratio.

  6. Impedance dispersion analysis of drug-membrane interactions

    NASA Astrophysics Data System (ADS)

    Tacheva, Bilyana; Paarvanova, Boyana; Ivanov, Ivan T.; Karabaliev, Miroslav

    2017-11-01

    Thin lipid films modified glassy carbon electrodes (GCE) were used in this work as model system for studying the interactions between two antipsychotic phenothiazine drugs, chlorpromazine and thioridazine, and the lipid fraction of the biomembranes. The lipid films on the electrode surface were obtained through the thinning of film-forming lipid solution deposited between an electrolyte phase and the working GC electrode. The effects of the drugs on the lipid film structure were investigated by electrochemical impedance spectroscopy (EIS). To characterize the electric properties of the lipid film the impedance of the working GCE is modeled with an equivalent circuit consisting of parallel capacitance Cp and resistance Rp. These capacitance and resistance are not frequency independent but could be calculated as equivalent Cp and Rp for each measured frequency of the impedance spectrum and presented as functions of the frequency f, Cp = Cp(f) and Rp= Rp(f). For the lipid films used in this work, it is demonstrated that both Cp(f) and Rp(f) are well approximated with power-law functions. This behavior implies that the impedance Z of the films could be analysed in terms of the well-known constant-phase angle element (CPE), which is often used to describe the interfacial impedance of solid working electrodes.

  7. A systematic uncertainty analysis for liner impedance eduction technology

    NASA Astrophysics Data System (ADS)

    Zhou, Lin; Bodén, Hans

    2015-11-01

    The so-called impedance eduction technology is widely used for obtaining acoustic properties of liners used in aircraft engines. The measurement uncertainties for this technology are still not well understood though it is essential for data quality assessment and model validation. A systematic framework based on multivariate analysis is presented in this paper to provide 95 percent confidence interval uncertainty estimates in the process of impedance eduction. The analysis is made using a single mode straightforward method based on transmission coefficients involving the classic Ingard-Myers boundary condition. The multivariate technique makes it possible to obtain an uncertainty analysis for the possibly correlated real and imaginary parts of the complex quantities. The results show that the errors in impedance results at low frequency mainly depend on the variability of transmission coefficients, while the mean Mach number accuracy is the most important source of error at high frequencies. The effect of Mach numbers used in the wave dispersion equation and in the Ingard-Myers boundary condition has been separated for comparison of the outcome of impedance eduction. A local Mach number based on friction velocity is suggested as a way to reduce the inconsistencies found when estimating impedance using upstream and downstream acoustic excitation.

  8. Diagnostic criteria for mass lesions differentiating in electrical impedance mammography

    NASA Astrophysics Data System (ADS)

    A, Karpov; M, Korotkova

    2013-04-01

    The purpose of this research was to determine the diagnostic criteria for differentiating volumetric lesions in the mammary gland in electrical impedance mammography. The research was carried out utilizing the electrical impedance computer mammograph llMEIK v.5.6gg®, which enables to acquire images of 3-D conductivity distribution layers within mamma's tissues up to 5 cm depth. The weighted reciprocal projection method was employed to reconstruct the 3-D electric conductivity distribution of the examined organ. The results of 3,710 electrical impedance examinations were analyzed. The analysis of a volumetric lesion included assessment of its shape, contour, internal electrical structure and changes of the surrounding tissues. Moreover, mammary gland status was evaluated with the help of comparative and age-related electrical conductivity curves. The diagnostic chart is provided. Each criterion is measured in points. Using the numerical score for evaluation of mass and non-volumetric lesions within the mammary gland in electrical impedance mammography allowed comparing this information to BI-RADS categories developed by American College of Radiology experts. The article is illustrated with electrical impedance mammograms and tables.

  9. A Case of Aerophagia Diagnosed by Multichannel Intraluminal Impedance Monitoring.

    PubMed

    Sohn, Ki Chang; Jeong, Young Hoon; Jo, Dong Ho; Heo, Won Gak; Yeom, Dong Han; Choi, Suck Chei; Ryu, Han Seung

    2015-11-01

    Aerophagia is a disorder caused by abnormal accumulation of air in the gastrointestinal tract as a result of repetitive and frequent inflow of air through the mouth. For the diagnosis of this condition, it is difficult to objectively measure the air swallowing. However, multichannel intraluminal impedance monitoring facilitates the differential diagnosis between normal air swallowing and pathologic aerophagia, and can aid in the determination of the frequency and amount of air swallowed. In this report, in addition to a literature review, we describe a case of 36-year-old man with abdominal distension who was diagnosed with aerophagia using esophageal impedance monitoring and was treated with clonazepam.

  10. Impedance spectroscopy of water soluble resin modified by zirconium sulphate

    NASA Astrophysics Data System (ADS)

    Joseph, Anandraj; Joshi, Girish M.

    2018-04-01

    We successfully modified water soluble resin polyvinyl alcohol (PVA) by loading zirconium sulphate (ZrSO4). We demonstrated the measurement of electrical properties by using impedance analyser across frequency range (10 Hz-1 MHz) and the temperature range of (30°C to 150°C). The impedance spectroscopy demonstrates decrease in bulk resistance as a function of temperature loading of zirconia 2.5 wt. %. Increase in AC (10-5 S/cm and DC conductivity (10- 2 S/m) observed due to ionic contribution of zirconia. However, the electrical properties of PVA/ZrSO4 composite useful to develop battery electrolyte applications.

  11. Bayesian identification of acoustic impedance in treated ducts.

    PubMed

    Buot de l'Épine, Y; Chazot, J-D; Ville, J-M

    2015-07-01

    The noise reduction of a liner placed in the nacelle of a turbofan engine is still difficult to predict due to the lack of knowledge of its acoustic impedance that depends on grazing flow profile, mode order, and sound pressure level. An eduction method, based on a Bayesian approach, is presented here to adjust an impedance model of the liner from sound pressures measured in a rectangular treated duct under multimodal propagation and flow. The cost function is regularized with prior information provided by Guess's [J. Sound Vib. 40, 119-137 (1975)] impedance of a perforated plate. The multi-parameter optimization is achieved with an Evolutionary-Markov-Chain-Monte-Carlo algorithm.

  12. Creating low-impedance tetrodes by electroplating with additives

    PubMed Central

    Ferguson, John E.; Boldt, Chris; Redish, A. David

    2011-01-01

    A tetrode is a bundle of four microwires that can record from multiple neurons simultaneously in the brain of a freely moving animal. Tetrodes are usually electroplated to reduce impedances from 2-3 MΩ to 200-500 kΩ (measured at 1 kHz), which increases the signal-to-noise ratio and allows for the recording of small amplitude signals. Tetrodes with even lower impedances could improve neural recordings but cannot be made using standard electroplating methods without shorting. We were able to electroplate tetrodes to 30-70 kΩ by adding polyethylene glycol (PEG) or multi-walled carbon nanotube (MWCNT) solutions to a commercial gold-plating solution. The MWCNTs and PEG acted as inhibitors in the electroplating process and created large-surface-area, low-impedance coatings on the tetrode tips. PMID:21379404

  13. Multichannel intraluminal impedance: general principles and technical issues.

    PubMed

    Tutuian, Radu; Castell, Donald O

    2005-04-01

    Multichannel intraluminal impedance (MII) is a new technology that allows detection of bolus movement without the use of external radiation or radiolabeled substances. The principles of MII are based on changes in resistance to alternating electrical current (impedance) induced by the presence of various boluses within the esophagus. The timing of changes in multiple impedance-measuring segments in the esophagus allows determination of the direction of bolus movement. Combined MII and manometry (MII-EM) provides simultaneous information on intraesophageal pressures and bolus transit, offers the ability to monitor all types of reflux, and allows the detection of the physical (liquid, gas, or mixed) and chemical (acid, nonacid) characteristics of the gastroesophageal refluxate.

  14. Primary Multi-frequency Data Analyze in Electrical Impedance Scanning.

    PubMed

    Liu, Ruigang; Dong, Xiuzhen; Fu, Feng; Shi, Xuetao; You, Fusheng; Ji, Zhenyu

    2005-01-01

    This paper deduced the Cole-Cole arc equation in form of admittance by the traditional Cole-Cole equation in form of impedance. Comparing to the latter, the former is more adaptive to the electrical impedance scanning which using lower frequency region. When using our own electrical impedance scanning device at 50-5000Hz, the measurement data separated on the arc of the former, while collected near the direct current resistor on the arc of the latter. The four parameters of the former can be evaluated by the least square method. The frequency of the imaginary part of admittance reaching maximum can be calculated by the Cole-Cole parameters. In conclusion, the Cole-Cole arc in form of admittance is more effective to multi-frequency data analyze at lower frequency region, like EIS.

  15. Quantification of temperature effect on impedance monitoring via PZT interface for prestressed tendon anchorage

    NASA Astrophysics Data System (ADS)

    Huynh, Thanh-Canh; Kim, Jeong-Tae

    2017-12-01

    In this study, the quantification of temperature effect on impedance monitoring via a PZT interface for prestressed tendon-anchorage is presented. Firstly, a PZT interface-based impedance monitoring technique is selected to monitor impedance signatures by predetermining sensitive frequency bands. An analytical model is designed to represent coupled dynamic responses of the PZT interface-tendon anchorage system. Secondly, experiments on a lab-scaled tendon anchorage are described. Impedance signatures are measured via the PZT interface for a series of temperature and prestress-force changes. Thirdly, temperature effects on measured impedance responses of the tendon anchorage are estimated by quantifying relative changes in impedance features (such as RMSD and CCD indices) induced by temperature variation and prestress-force change. Finally, finite element analyses are conducted to investigate the mechanism of temperature variation and prestress-loss effects on the impedance responses of prestressed tendon anchorage. Temperature effects on impedance monitoring are filtered by effective frequency shift-based algorithm for distinguishing prestress-loss effects on impedance signatures.

  16. Organic electrochemical transistors for cell-based impedance sensing

    NASA Astrophysics Data System (ADS)

    Rivnay, Jonathan; Ramuz, Marc; Leleux, Pierre; Hama, Adel; Huerta, Miriam; Owens, Roisin M.

    2015-01-01

    Electrical impedance sensing of biological systems, especially cultured epithelial cell layers, is now a common technique to monitor cell motion, morphology, and cell layer/tissue integrity for high throughput toxicology screening. Existing methods to measure electrical impedance most often rely on a two electrode configuration, where low frequency signals are challenging to obtain for small devices and for tissues with high resistance, due to low current. Organic electrochemical transistors (OECTs) are conducting polymer-based devices, which have been shown to efficiently transduce and amplify low-level ionic fluxes in biological systems into electronic output signals. In this work, we combine OECT-based drain current measurements with simultaneous measurement of more traditional impedance sensing using the gate current to produce complex impedance traces, which show low error at both low and high frequencies. We apply this technique in vitro to a model epithelial tissue layer and show that the data can be fit to an equivalent circuit model yielding trans-epithelial resistance and cell layer capacitance values in agreement with literature. Importantly, the combined measurement allows for low biases across the cell layer, while still maintaining good broadband signal.

  17. Organic electrochemical transistors for cell-based impedance sensing

    SciTech Connect

    Rivnay, Jonathan, E-mail: rivnay@emse.fr, E-mail: owens@emse.fr; Ramuz, Marc; Hama, Adel

    2015-01-26

    Electrical impedance sensing of biological systems, especially cultured epithelial cell layers, is now a common technique to monitor cell motion, morphology, and cell layer/tissue integrity for high throughput toxicology screening. Existing methods to measure electrical impedance most often rely on a two electrode configuration, where low frequency signals are challenging to obtain for small devices and for tissues with high resistance, due to low current. Organic electrochemical transistors (OECTs) are conducting polymer-based devices, which have been shown to efficiently transduce and amplify low-level ionic fluxes in biological systems into electronic output signals. In this work, we combine OECT-based drain currentmore » measurements with simultaneous measurement of more traditional impedance sensing using the gate current to produce complex impedance traces, which show low error at both low and high frequencies. We apply this technique in vitro to a model epithelial tissue layer and show that the data can be fit to an equivalent circuit model yielding trans-epithelial resistance and cell layer capacitance values in agreement with literature. Importantly, the combined measurement allows for low biases across the cell layer, while still maintaining good broadband signal.« less

  18. Corrosion Study Using Electrochemical Impedance Spectroscopy

    NASA Technical Reports Server (NTRS)

    Farooq, Muhammad Umar

    2003-01-01

    Corrosion is a common phenomenon. It is the destructive result of chemical reaction between a metal or metal alloy and its environment. Stainless steel tubing is used at Kennedy Space Center for various supply lines which service the orbiter. The launch pads are also made of stainless steel. The environment at the launch site has very high chloride content due to the proximity to the Atlantic Ocean. Also, during a launch, the exhaust products in the solid rocket boosters include concentrated hydrogen chloride. The purpose of this project was to study various alloys by Electrochemical Impedance Spectroscopy in corrosive environments similar to the launch sites. This report includes data and analysis of the measurements for 304L, 254SMO and AL-6XN in primarily neutral 3.55% NaCl. One set of data for 304L in neutral 3.55%NaCl + 0.1N HCl is also included.

  19. Electrical Impedance Tomography of Electrolysis

    PubMed Central

    Meir, Arie; Rubinsky, Boris

    2015-01-01

    The primary goal of this study is to explore the hypothesis that changes in pH during electrolysis can be detected with Electrical Impedance Tomography (EIT). The study has relevance to real time control of minimally invasive surgery with electrolytic ablation. To investigate the hypothesis, we compare EIT reconstructed images to optical images acquired using pH-sensitive dyes embedded in a physiological saline agar gel phantom treated with electrolysis. We further demonstrate the biological relevance of our work using a bacterial E.Coli model, grown on the phantom. The results demonstrate the ability of EIT to image pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E.coli model. The results are promising, and invite further experimental explorations. PMID:26039686

  20. Impedance-controlled ultrasound probe

    NASA Astrophysics Data System (ADS)

    Gilbertson, Matthew W.; Anthony, Brian W.

    2011-03-01

    An actuated hand-held impedance-controlled ultrasound probe has been developed. The controller maintains a prescribed contact state (force and velocity) between the probe and a patient's body. The device will enhance the diagnostic capability of free-hand elastography and swept-force compound imaging, and also make it easier for a technician to acquire repeatable (i.e. directly comparable) images over time. The mechanical system consists of an ultrasound probe, ball-screw-driven linear actuator, and a force/torque sensor. The feedback controller commands the motor to rotate the ball-screw to translate the ultrasound probe in order to maintain a desired contact force. It was found that users of the device, with the control system engaged, maintain a constant contact force with 15 times less variation than without the controller engaged. The system was used to determine the elastic properties of soft tissue.

  1. Simulating Reflex Induced Changes in the Acoustic Impedance of the Ear.

    ERIC Educational Resources Information Center

    Sirlin, Mindy W.; Levitt, Harry

    1991-01-01

    A simple procedure for measuring changes in the acoustic impedance of the ear is described. The technique has several applications, including simulation using a standard coupler of changes in real ear impedance produced by the acoustic reflex, and calibration of response time of an otoadmittance meter. (Author/DB)

  2. Transition metal oxide as anode interface buffer for impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Xu, Hui; Tang, Chao; Wang, Xu-Liang; Zhai, Wen-Juan; Liu, Rui-Lan; Rong, Zhou; Pang, Zong-Qiang; Jiang, Bing; Fan, Qu-Li; Huang, Wei

    2015-12-01

    Impedance spectroscopy is a strong method in electric measurement, which also shows powerful function in research of carrier dynamics in organic semiconductors when suitable mathematical physical models are used. Apart from this, another requirement is that the contact interface between the electrode and materials should at least be quasi-ohmic contact. So in this report, three different transitional metal oxides, V2O5, MoO3 and WO3 were used as hole injection buffer for interface of ITO/NPB. Through the impedance spectroscopy and PSO algorithm, the carrier mobilities and I-V characteristics of the NPB in different devices were measured. Then the data curves were compared with the single layer device without the interface layer in order to investigate the influence of transitional metal oxides on the carrier mobility. The careful research showed that when the work function (WF) of the buffer material was just between the work function of anode and the HOMO of the organic material, such interface material could work as a good bridge for carrier injection. Under such condition, the carrier mobility measured through impedance spectroscopy should be close to the intrinsic value. Considering that the HOMO (or LUMO) of most organic semiconductors did not match with the work function of the electrode, this report also provides a method for wide application of impedance spectroscopy to the research of carrier dynamics.

  3. Validation of a New Procedure for Impedance Eduction in Flow

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.

    2010-01-01

    A new impedance eduction procedure is validated by comparing the educed impedance spectrum to that of an older but well-tested eduction procedure. The older procedure requires the installation of a microphone array in the liner test section but the new procedure removes this requirement. A 12.7-mm stainless steel plate and a conventional liner consisting of a perforated plate bonded to a honeycomb core are tested. Test data is acquired from a grazing flow, impedance tube facility for a range of source frequencies and mean flow Mach numbers for which only plane waves are cut on. For the stainless steel plate, the educed admittance spectrum using the new procedure shows an improvement over that of the old procedure. This improvement shows up primarily in the educed conductance spectrum. Both eduction procedures show discrepancies in educed admittance in the mid-frequency range. Indications are that this discrepancy is triggered by an inconsistency between the measured eduction data (that contains boundary layer effects) and the two eduction models (for which the boundary layer is neglected). For the conventional liner, both eduction procedures are in very good agreement with each other. Small discrepancies occur for one or two frequencies in the mid-frequency range and for frequencies beyond the cut on frequency of higher-order duct modes. This discrepancy in the midfrequency range occurs because an automated optimizer is used to educe the impedance and the objective function used by the optimizer is extremely flat and therefore sensitive to initial starting values. The discrepancies at frequencies beyond the cut on frequency of higher order duct modes are due to the assumption of only plane waves in the impedance eduction model, although higher order modes are propagating in the impedance tube facility.

  4. PREFACE: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT)

    NASA Astrophysics Data System (ADS)

    Pliquett, Uwe

    2013-04-01

    Over recent years advanced measurement methods have facilitated outstanding achievements not only in medical instrumentation but also in biotechnology. Impedance measurement is a simple and innocuous way to characterize materials. For more than 40 years biological materials, most of them based on cells, have been characterized by means of electrical impedance for quality control of agricultural products, monitoring of biotechnological or food processes or in health care. Although the list of possible applications is long, very few applications successfully entered the market before the turn of the century. This was, on the one hand, due to the low specificity of electrical impedance with respect to other material properties because it is influenced by multiple factors. On the other hand, equipment and methods for many potential applications were not available. With the appearance of microcontrollers that could be easily integrated in applications at the beginning of the 1980s, impedance measurement advanced as a valuable tool in process optimization and lab automation. However, established methods and data processing were mostly used in a new environment. This has changed significantly during the last 10 years with a dramatic growth of the market for medical instrumentation and also for biotechnological applications. Today, advanced process monitoring and control require fast and highly parallel electrical characterization which in turn yields incredible data volumes that must be handled in real time. Many newer developments require miniaturized but precise sensing methods which is one of the main parts of Lab-on-Chip technology. Moreover, biosensors increasingly use impedometric transducers, which are not compatible with the large expensive measurement devices that are common in the laboratory environment. Following the achievements in the field of bioimpedance measurement, we will now witness a dramatic development of new electrode structures and electronics

  5. Bioelectrical impedance vector distribution in the first year of life.

    PubMed

    Savino, Francesco; Grasso, Giulia; Cresi, Francesco; Oggero, Roberto; Silvestro, Leandra

    2003-06-01

    We assessed the bioelectrical impedance vector distribution in a sample of healthy infants in the first year of life, which is not available in literature. The study was conducted as a cross-sectional study in 153 healthy Caucasian infants (90 male and 63 female) younger than 1 y, born at full term, adequate for gestational age, free from chronic diseases or growth problems, and not feverish. Z scores for weight, length, cranial circumference, and body mass index for the study population were within the range of +/-1.5 standard deviations according to the Euro-Growth Study references. Concurrent anthropometrics (weight, length, and cranial circumference), body mass index, and bioelectrical impedance (resistance and reactance) measurements were made by the same operator. Whole-body (hand to foot) tetrapolar measurements were performed with a single-frequency (50 kHz), phase-sensitive impedance analyzer. The study population was subdivided into three classes of age for statistical analysis: 0 to 3.99 mo, 4 to 7.99 mo, and 8 to 11.99 mo. Using the bivariate normal distribution of resistance and reactance components standardized by the infant's length, the bivariate 95% confidence limits for the mean impedance vector separated by sex and age groups were calculated and plotted. Further, the bivariate 95%, 75%, and 50% tolerance intervals for individual vector measurements in the first year of life were plotted. Resistance and reactance values often fluctuated during the first year of life, particularly as raw measurements (without normalization by subject's length). However, 95% confidence ellipses of mean vectors from the three age groups overlapped each other, as did confidence ellipses by sex for each age class, indicating no significant vector migration during the first year of life. We obtained an estimate of mean impedance vector in a sample of healthy infants in the first year of life and calculated the bivariate values for an individual vector (95%, 75%, and 50

  6. Acute evaluation of transthoracic impedance vectors using ICD leads.

    PubMed

    Gottfridsson, Christer; Daum, Douglas; Kennergren, Charles; Ramuzat, Agnès; Willems, Roger; Edvardsson, Nils

    2009-06-01

    Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.

  7. Impedance changes during setting of amorphous calcium phosphate composites.

    PubMed

    Par, Matej; Šantić, Ana; Gamulin, Ozren; Marovic, Danijela; Moguš-Milanković, Andrea; Tarle, Zrinka

    2016-11-01

    To investigate the electrical properties of experimental light-curable composite materials based on amorphous calcium phosphate (ACP) with the admixture of silanized barium glass and silica fillers. Short-term setting was investigated by impedance measurements at a frequency of 1kHz, while for the long-term setting the impedance spectra were measured consecutively over a frequency range of 0.05Hz to 1MHz for 24h. The analysis of electrical resistivity changes during curing allowed the extraction of relevant kinetic parameters. The impedance results were correlated to the degree of conversion assessed by Raman spectroscopy, water content determined by gravimetry, light transmittance measured by CCD spectrometer and microstructural features observed by scanning electron microscopy. ACP-based composites have shown higher immediate degree of conversion and less post-cure polymerization than the control composites, but lower polymerization rate. The polymerization rate assessed by impedance measurements correlated well with the light transmittance. The differences in the electrical conductivity values observed among the materials were correlated to the amount of water introduced into composites by the ACP filler. High correlation was found between the degree of conversion and electrical resistivity. Equivalent circuit modeling revealed two electrical contributions for the ACP-based composites and a single contribution for the control composites. The impedance spectroscopy has proven a valuable method for gaining insight into various features of ACP-based composites. Better understanding of the properties of ACP-based composites should further the development of these promising bioactive materials. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors

    PubMed Central

    Khoury, Dirar S.; Naware, Mihir; Siou, Jeff; Blomqvist, Andreas; Mathuria, Nilesh S.; Wang, Jianwen; Shih, Hue-Teh; Nagueh, Sherif F.; Panescu, Dorin

    2009-01-01

    Objectives To investigate properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy (CRT) system. Background Monitoring of CHF has relied mainly on right-heart sensors. Methods Fifteen normal dogs underwent implantation of CRT systems using standard leads. An additional left atrial (LA) pressure lead-sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathorcaic and intracardiac vectors, were measured via ring (r), coil (c), and device Can electrodes. Results All animals developed CHF after 2–4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LVr-Can, −17%; LVr-RVr, −15%; LVr-RAr, −11%; RVr-Can, −12%; RVc-Can, −7%; RAr-Can, −5%. The LVr-Can vector reflected both the fastest and largest change in impedance in comparison to vectors employing only right-heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure. Conclusions Impedance, acquired via different lead-electrodes, have variable responses to CHF. Impedance vectors employing a LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients. PMID:19298923

  9. Multivariable Dynamic Ankle Mechanical Impedance With Active Muscles

    PubMed Central

    Lee, Hyunglae; Krebs, Hermano Igo; Hogan, Neville

    2015-01-01

    Multivariable dynamic ankle mechanical impedance in two coupled degrees-of-freedom (DOFs) was quantified when muscles were active. Measurements were performed at five different target activation levels of tibialis anterior and soleus, from 10% to 30% of maximum voluntary contraction (MVC) with increments of 5% MVC. Interestingly, several ankle behaviors characterized in our previous study of the relaxed ankle were observed with muscles active: ankle mechanical impedance in joint coordinates showed responses largely consistent with a second-order system consisting of inertia, viscosity, and stiffness; stiffness was greater in the sagittal plane than in the frontal plane at all activation conditions for all subjects; and the coupling between dorsiflexion–plantarflexion and inversion–eversion was small—the two DOF measurements were well explained by a strictly diagonal impedance matrix. In general, ankle stiffness increased linearly with muscle activation in all directions in the 2-D space formed by the sagittal and frontal planes, but more in the sagittal than in the frontal plane, resulting in an accentuated “peanut shape.” This characterization of young healthy subjects’ ankle mechanical impedance with active muscles will serve as a baseline to investigate pathophysiological ankle behaviors of biomechanically and/or neurologically impaired patients. PMID:25203497

  10. Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition.

    PubMed

    Wang, Fu-Tai; Chan, Hsiao-Lung; Wang, Chun-Li; Jian, Hung-Ming; Lin, Sheng-Hsiung

    2015-07-07

    Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD) can decompose a signal into several intrinsic mode functions (IMFs) that disclose nonstationary components as well as stationary components and, similarly, capture respiratory episodes from thoracic impedance. However, upper-body movements usually produce motion artifacts that are not easily removed by digital filtering. Moreover, large motion artifacts disable the EMD to decompose respiratory components. In this paper, motion artifacts are detected and replaced by the data mirrored from the prior and the posterior before EMD processing. A novel intrinsic respiratory reconstruction index that considers both global and local properties of IMFs is proposed to define respiration-related IMFs for respiration reconstruction and instantaneous respiratory estimation. Based on the experiments performing a series of static and dynamic physical activates, our results showed the proposed method had higher cross correlations between respiratory frequencies estimated from thoracic impedance and those from oronasal airflow based on small window size compared to the Fourier transform-based method.

  11. Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition

    PubMed Central

    Wang, Fu-Tai; Chan, Hsiao-Lung; Wang, Chun-Li; Jian, Hung-Ming; Lin, Sheng-Hsiung

    2015-01-01

    Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD) can decompose a signal into several intrinsic mode functions (IMFs) that disclose nonstationary components as well as stationary components and, similarly, capture respiratory episodes from thoracic impedance. However, upper-body movements usually produce motion artifacts that are not easily removed by digital filtering. Moreover, large motion artifacts disable the EMD to decompose respiratory components. In this paper, motion artifacts are detected and replaced by the data mirrored from the prior and the posterior before EMD processing. A novel intrinsic respiratory reconstruction index that considers both global and local properties of IMFs is proposed to define respiration-related IMFs for respiration reconstruction and instantaneous respiratory estimation. Based on the experiments performing a series of static and dynamic physical activates, our results showed the proposed method had higher cross correlations between respiratory frequencies estimated from thoracic impedance and those from oronasal airflow based on small window size compared to the Fourier transform-based method. PMID:26198231

  12. Combined electromechanical impedance and fiber optic diagnosis of aerospace structures

    NASA Astrophysics Data System (ADS)

    Schlavin, Jon; Zagrai, Andrei; Clemens, Rebecca; Black, Richard J.; Costa, Joey; Moslehi, Behzad; Patel, Ronak; Sotoudeh, Vahid; Faridian, Fereydoun

    2014-03-01

    Electromechanical impedance is a popular diagnostic method for assessing structural conditions at high frequencies. It has been utilized, and shown utility, in aeronautic, space, naval, civil, mechanical, and other types of structures. By contrast, fiber optic sensing initially found its niche in static strain measurement and low frequency structural dynamic testing. Any low frequency limitations of the fiber optic sensing, however, are mainly governed by its hardware elements. As hardware improves, so does the bandwidth (frequency range * number of sensors) provided by the appropriate enabling fiber optic sensor interrogation system. In this contribution we demonstrate simultaneous high frequency measurements using fiber optic and electromechanical impedance structural health monitoring technologies. A laboratory specimen imitating an aircraft wing structure, incorporating surfaces with adjustable boundary conditions, was instrumented with piezoelectric and fiber optic sensors. Experiments were conducted at different structural boundary conditions associated with deterioration of structural health. High frequency dynamic responses were collected at multiple locations on a laboratory wing specimen and conclusions were drawn about correspondence between structural damage and dynamic signatures as well as correlation between electromechanical impedance and fiber optic sensors spectra. Theoretical investigation of the effect of boundary conditions on electromechanical impedance spectra is presented and connection to low frequency structural dynamics is suggested. It is envisioned that acquisition of high frequency structural dynamic responses with multiple fiber optic sensors may open new diagnostic capabilities for fiber optic sensing technologies.

  13. 21 CFR 870.2750 - Impedance phlebograph.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Impedance phlebograph. 870.2750 Section 870.2750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2750 Impedance phlebograph...

  14. 21 CFR 870.2770 - Impedance plethysmograph.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Impedance plethysmograph. 870.2770 Section 870.2770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2770 Impedance...

  15. Possibilities of electrical impedance tomography in gynecology

    NASA Astrophysics Data System (ADS)

    V, Trokhanova O.; A, Chijova Y.; B, Okhapkin M.; V, Korjenevsky A.; S, Tuykin T.

    2013-04-01

    The paper describes results of comprehensive EIT diagnostics of mammary glands and cervix. The data were obtained from examinations of 170 patients by EIT system MEM (multi-frequency electrical impedance mammograph) and EIT system GIT (gynecological impedance tomograph). Mutual dependence is discussed.

  16. FDTD modeling of thin impedance sheets

    NASA Technical Reports Server (NTRS)

    Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    Thin sheets of resistive or dielectric material are commonly encountered in radar cross section calculations. Analysis of such sheets is simplified by using sheet impedances. In this paper it is shown that sheet impedances can be modeled easily and accurately using Finite Difference Time Domain (FDTD) methods.

  17. Complex Impedance of Fast Optical Transition Edge Sensors up to 30 MHz

    NASA Astrophysics Data System (ADS)

    Hattori, K.; Kobayashi, R.; Numata, T.; Inoue, S.; Fukuda, D.

    2018-03-01

    Optical transition edge sensors (TESs) are characterized by a very fast response, of the order of μs, which is 10^3 times faster than TESs for X-ray and gamma-ray. To extract important parameters associated with the optical TES, complex impedances at high frequencies (> 1 MHz) need to be measured, where the parasitic impedance in the circuit and reflections of electrical signals due to discontinuities in the characteristic impedance of the readout circuits become significant. This prevents the measurements of the current sensitivity β , which can be extracted from the complex impedance. In usual setups, it is hard to build a circuit model taking into account the parasitic impedances and reflections. In this study, we present an alternative method to estimate a transfer function without investigating the details of the entire circuit. Based on this method, the complex impedance up to 30 MHz was measured. The parameters were extracted from the impedance and were compared with other measurements. Using these parameters, we calculated the theoretical limit on an energy resolution and compared it with the measured energy resolution. In this paper, the reasons for the deviation of the measured value from theoretically predicted values will be discussed.

  18. [Monitoring of extra- and intra-cellular compartment through total body impedance (author's transl)].

    PubMed

    Raggueneau, J L; Gambini, D; Levante, A; Riche, F; de Vernejoul, P; Echter, E

    1979-01-01

    To evaluate the extra-cellular space, we measure the impedance (or resistance) of the extra-cellular electrolyte compartment with an alternating current at a fixed frequency of 5 kHz that can't pass through the cellular membrane. Total water is measured by the impedance to a current of 1 MHz which is conducted by extra and intra cellular hydro-electrolytic space. There is a good correlation between electrical impedance measurements and distribution of isotopic markers. The extra-cellular compartment was evaluated by diffusion of D.T.P.A. marked with 99mTc or with 111In and the total water by the diffusion of Antipyrin marked with 1,311 or 1,231. The findings indicate that there is not a significant difference between the results of the size of extra-cellular water measured by electrical impedance and D.T.P.A. diffusion (r = 0.75). Comparable results have been obtained in the determination of total water by electrical impedance measure and diffusion of Antipyrin (r = 0.90). We have also studied by method of electric impedance:--The state of hydratation in head injured patients and after pituitary surgery.--The lean body mass and hydro-electrolyte compartments in pregnancy. Electrical impedance measure seems to be a simple and reliable method to assess the hydric state of patients.

  19. Impedance analysis of a disk-type SOFC using doped lanthanum gallate under power generation

    NASA Astrophysics Data System (ADS)

    Kato, Tohru; Nozaki, Ken; Negishi, Akira; Kato, Ken; Monma, Akihiko; Kaga, Yasuo; Nagata, Susumu; Takano, Kiyonami; Inagaki, Toru; Yoshida, Hiroyuki; Hosoi, Kei; Hoshino, Koji; Akbay, Taner; Akikusa, Jun

    Impedance measurements were carried out under practical power generation conditions in a disk-type SOFC, which may be utilized as a small-scale power generator. The tested cell was composed of doped lanthanum gallate (La 0.8Sr 0.2Ga 0.8Mg 0.15Co 0.05O 3- δ) as the electrolyte, Sm 0.5Sr 0.5CoO 3 as the cathode electrode and Ni/Ce 0.8Sm 0.2O 2 cermet as the anode electrode. The cell impedance was measured between 10 mHz and 10 kHz by varying the fuel utilization and gas flow rate and plotted in complex impedance diagrams. The observed impedance shows a large semi-circular pattern on the low frequency side. The semi-circular impedance, having a noticeably low characteristic frequency between 0.13 and 0.4 Hz, comes from the change in gas composition, originally caused by the cell reaction. The change in impedance with the fuel utilization (load current) and the gas flow rate agreed qualitatively well with the theoretical predictions from a simulation. This impedance was dominant under high fuel-utilization power-generation conditions. The impedance, which described the activation polarizations in the electrode reactions, was comparatively small and scarcely changed with the change in fuel utilization (load current) and gas flow rate.

  20. Estimating surface acoustic impedance with the inverse method.

    PubMed

    Piechowicz, Janusz

    2011-01-01

    Sound field parameters are predicted with numerical methods in sound control systems, in acoustic designs of building and in sound field simulations. Those methods define the acoustic properties of surfaces, such as sound absorption coefficients or acoustic impedance, to determine boundary conditions. Several in situ measurement techniques were developed; one of them uses 2 microphones to measure direct and reflected sound over a planar test surface. Another approach is used in the inverse boundary elements method, in which estimating acoustic impedance of a surface is expressed as an inverse boundary problem. The boundary values can be found from multipoint sound pressure measurements in the interior of a room. This method can be applied to arbitrarily-shaped surfaces. This investigation is part of a research programme on using inverse methods in industrial room acoustics.

  1. Three-dimensional electrical impedance tomography: a topology optimization approach.

    PubMed

    Mello, Luís Augusto Motta; de Lima, Cícero Ribeiro; Amato, Marcelo Britto Passos; Lima, Raul Gonzalez; Silva, Emílio Carlos Nelli

    2008-02-01

    Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.

  2. Impedance-based structural health monitoring of wind turbine blades

    NASA Astrophysics Data System (ADS)

    Pitchford, Corey; Grisso, Benjamin L.; Inman, Daniel J.

    2007-04-01

    Wind power is a fast-growing source of non-polluting, renewable energy with vast potential. However, current wind turbine technology must be improved before the potential of wind power can be fully realized. Wind turbine blades are one of the key components in improving this technology. Blade failure is very costly because it can damage other blades, the wind turbine itself, and possibly other wind turbines. A successful damage detection system incorporated into wind turbines could extend blade life and allow for less conservative designs. A damage detection method which has shown promise on a wide variety of structures is impedance-based structural health monitoring. The technique utilizes small piezoceramic (PZT) patches attached to a structure as self-sensing actuators to both excite the structure with high-frequency excitations, and monitor any changes in structural mechanical impedance. By monitoring the electrical impedance of the PZT, assessments can be made about the integrity of the mechanical structure. Recently, advances in hardware systems with onboard computing, including actuation and sensing, computational algorithms, and wireless telemetry, have improved the accessibility of the impedance method for in-field measurements. This paper investigates the feasibility of implementing such an onboard system inside of turbine blades as an in-field method of damage detection. Viability of onboard detection is accomplished by running a series of tests to verify the capability of the method on an actual wind turbine blade section from an experimental carbon/glass/balsa composite blade developed at Sandia National Laboratories.

  3. High-density CMOS Microelectrode Array System for Impedance Spectroscopy and Imaging of Biological Cells.

    PubMed

    Vijay, Viswam; Raziyeh, Bounik; Amir, Shadmani; Jelena, Dragas; Alicia, Boos Julia; Axel, Birchler; Jan, Müller; Yihui, Chen; Andreas, Hierlemann

    2017-01-26

    A monolithic measurement platform was implemented to enable label-free in-vitro electrical impedance spectroscopy measurements of cells on multi-functional CMOS microelectrode array. The array includes 59,760 platinum microelectrodes, densely packed within a 4.5 mm × 2.5 mm sensing region at a pitch of 13.5 μm. The 32 on-chip lock-in amplifiers can be used to measure the impedance of any arbitrarily chosen electrodes on the array by applying a sinusoidal voltage, generated by an on-chip waveform generator with a frequency range from 1 Hz to 1 MHz, and measuring the respective current. Proof-of-concept measurements of impedance sensing and imaging are shown in this paper. Correlations between cell detection through optical microscopy and electrochemical impedance scanning were established.

  4. Tracking of electrochemical impedance of batteries

    NASA Astrophysics Data System (ADS)

    Piret, H.; Granjon, P.; Guillet, N.; Cattin, V.

    2016-04-01

    This paper presents an evolutionary battery impedance estimation method, which can be easily embedded in vehicles or nomad devices. The proposed method not only allows an accurate frequency impedance estimation, but also a tracking of its temporal evolution contrary to classical electrochemical impedance spectroscopy methods. Taking into account constraints of cost and complexity, we propose to use the existing electronics of current control to perform a frequency evolutionary estimation of the electrochemical impedance. The developed method uses a simple wideband input signal, and relies on a recursive local average of Fourier transforms. The averaging is controlled by a single parameter, managing a trade-off between tracking and estimation performance. This normalized parameter allows to correctly adapt the behavior of the proposed estimator to the variations of the impedance. The advantage of the proposed method is twofold: the method is easy to embed into a simple electronic circuit, and the battery impedance estimator is evolutionary. The ability of the method to monitor the impedance over time is demonstrated on a simulator, and on a real Lithium ion battery, on which a repeatability study is carried out. The experiments reveal good tracking results, and estimation performance as accurate as the usual laboratory approaches.

  5. Rotor damage detection by using piezoelectric impedance

    NASA Astrophysics Data System (ADS)

    Qin, Y.; Tao, Y.; Mao, Y. F.

    2016-04-01

    Rotor is a core component of rotary machinery. Once the rotor has the damage, it may lead to a major accident. Thus the quantitative rotor damage detection method based on piezoelectric impedance is studied in this paper. With the governing equation of piezoelectric transducer (PZT) in a cylindrical coordinate, the displacement along the radius direction is derived. The charge of PZT is calculated by the electric displacement. Then, by the use of the obtained displacement and charge, an analytic piezoelectric impedance model of the rotor is built. Given the circular boundary condition of a rotor, annular elements are used as the analyzed objects and spectral element method is used to set up the damage detection model. The Electro-Mechanical (E/M) coupled impedance expression of an undamaged rotor is deduced with the application of a low-cost impedance test circuit. A Taylor expansion method is used to obtain the approximate E/M coupled impedance expression for the damaged rotor. After obtaining the difference between the undamaged and damaged rotor impedance, a rotor damage detection method is proposed. This method can directly calculate the change of bending stiffness of the structural elements, it follows that the rotor damage can be effectively detected. Finally, a preset damage configuration is used for the numerical simulation. The result shows that the quantitative damage detection algorithm based on spectral element method and piezoelectric impedance proposed in this paper can identify the location and the severity of the damaged rotor accurately.

  6. Coupling impedance and wake functions for laminated structures with an application to the Fermilab Booster

    DOE PAGES

    Macridin, Alexandru; Spentzouris, Panagiotis; Amundson, James; ...

    2011-06-28

    We calculate the impedance and wake functions for laminated structures with parallel-plane and circular geometries. We critically examine the approximations used in the literature for the coupling impedance in laminated chambers and find that most of them are not justified because the wall surface impedance is large. A comparison between flat and circular geometry impedances is presented. We apply our calculation in a state-of-the-art beam dynamics simulation of the Fermilab Booster which includes nonlinear optics, laminated wakefields, and space charge impedance. The latter can have a significant effect away from the ultrarelativistic limit. Even though the simulations and the comparisonmore » with the experiment are done at the Booster injection energy, where the relativistic factor γ = 1.42, we find good agreement between our calculation of the coherent tune shift and recent experimental measurements.« less

  7. FDTD modeling of thin impedance sheets

    NASA Technical Reports Server (NTRS)

    Luebbers, Raymond; Kunz, Karl

    1991-01-01

    Thin sheets of resistive or dielectric material are commonly encountered in radar cross section calculations. Analysis of such sheets is simplified by using sheet impedances. It is shown that sheet impedances can be modeled easily and accurately using Finite Difference Time Domain (FDTD) methods. These sheets are characterized by a discontinuity in the tangential magnetic field on either side of the sheet but no discontinuity in tangential electric field. This continuity, or single valued behavior of the electric field, allows the sheet current to be expressed in terms of an impedance multiplying this electric field.

  8. Electrical impedance myography in facioscapulohumeral muscular dystrophy.

    PubMed

    Statland, Jeffrey M; Heatwole, Chad; Eichinger, Katy; Dilek, Nuran; Martens, William B; Tawil, Rabi

    2016-10-01

    In this study we determined the reliability and validity of electrical impedance myography (EIM) in facioscapulohumeral muscular dystrophy (FSHD). We performed a prospective study of EIM on 16 bilateral limb and trunk muscles in 35 genetically defined and clinically affected FSHD patients (reliability testing on 18 patients). Summary scores based on body region were derived. Reactance and phase (50 and 100 kHz) were compared with measures of strength, FSHD disease severity, and functional outcomes. Participants were mostly men, mean age 53.0 years, and included a full range of severity. Limb and trunk muscles showed good to excellent reliability [intraclass correlation coefficients (ICC) 0.72-0.99]. Summary scores for the arm, leg, and trunk showed excellent reliability (ICC 0.89-0.98). Reactance was the most sensitive EIM parameter to a broad range of FSHD disease metrics. EIM is a reliable measure of muscle composition in FSHD that offers the possibility to serially evaluate affected muscles. Muscle Nerve 54: 696-701, 2016. © 2016 Wiley Periodicals, Inc.

  9. Embedded silver PDMS electrodes for single cell electrical impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Wei, Yuan; Xu, Zhensong; Cachia, Mark A.; Nguyen, John; Zheng, Yi; Wang, Chen; Sun, Yu

    2016-09-01

    This paper presents a microfluidic device with wide channels and embedded AgPDMS electrodes for measuring the electrical properties of single cells. The work demonstrates the feasibility of using a large channel design and embedded electrodes for impedance spectroscopy to circumvent issues such as channel clogging and limited device re-usability. AgPDMS electrodes were formed on channel sidewalls for impedance detection and cell electrical properties measurement. Equivalent circuit models were used to interpret multi-frequency impedance data to quantify each cell’s cytoplasm conductivity and specific membrane capacitance. T24 cells were tested to validate the microfluidic system and modeling results. Comparisons were then made by measuring two leukemia cell lines (AML-2 and HL-60) which were found to have different cytoplasm conductivity values (0.29  ±  0.15 S m-1 versus 0.47  ±  0.20 S m-1) and specific membrane capacitance values (41  ±  25 mF m-2 versus 55  ±  26 mF m-2) when the cells were flown through the wide channel and measured by the AgPDMS electrodes.

  10. Sonic impedance technique detects flaws in polyurethane foam spray-on insulation

    NASA Technical Reports Server (NTRS)

    Haralson, H. S.; Haynes, J. L.

    1970-01-01

    Sonic impedance testing detects voids and unbonded regions as small as 1 inch in diameter by 0.03 inch thick. Measurements are made manually or by automatic scanning and the readout is made by meter or recorder.

  11. Multivariable Dynamic Ankle Mechanical Impedance With Relaxed Muscles

    PubMed Central

    Lee, Hyunglae; Krebs, Hermano Igo; Hogan, Neville

    2015-01-01

    Neurological or biomechanical disorders may distort ankle mechanical impedance and thereby impair locomotor function. This paper presents a quantitative characterization of multivariable ankle mechanical impedance of young healthy subjects when their muscles were relaxed, to serve as a baseline to compare with pathophysiological ankle properties of biomechanically and/or neurologically impaired patients. Measurements using a highly backdrivable wearable ankle robot combined with multi-input multi-output stochastic system identification methods enabled reliable characterization of ankle mechanical impedance in two degrees-of-freedom (DOFs) simultaneously, the sagittal and frontal planes. The characterization included important ankle properties unavailable from single DOF studies: coupling between DOFs and anisotropy as a function of frequency. Ankle impedance in joint coordinates showed responses largely consistent with a second-order system consisting of inertia, viscosity, and stiffness in both seated (knee flexed) and standing (knee straightened) postures. Stiffness in the sagittal plane was greater than in the frontal plane and furthermore, was greater when standing than when seated, most likely due to the stretch of bi-articular muscles (medial and lateral gastrocnemius). Very low off-diagonal partial coherences implied negligible coupling between dorsiflexion-plantarflexion and inversion-eversion. The directions of principal axes were tilted slightly counterclockwise from the original joint coordinates. The directional variation (anisotropy) of ankle impedance in the 2-D space formed by rotations in the sagittal and frontal planes exhibited a characteristic “peanut” shape, weak in inversion-eversion over a wide range of frequencies from the stiffness dominated region up to the inertia dominated region. Implications for the assessment of neurological and biomechanical impairments are discussed. PMID:24686292

  12. Multivariable dynamic ankle mechanical impedance with relaxed muscles.

    PubMed

    Lee, Hyunglae; Krebs, Hermano Igo; Hogan, Neville

    2014-11-01

    Neurological or biomechanical disorders may distort ankle mechanical impedance and thereby impair locomotor function. This paper presents a quantitative characterization of multivariable ankle mechanical impedance of young healthy subjects when their muscles were relaxed, to serve as a baseline to compare with pathophysiological ankle properties of biomechanically and/or neurologically impaired patients. Measurements using a highly backdrivable wearable ankle robot combined with multi-input multi-output stochastic system identification methods enabled reliable characterization of ankle mechanical impedance in two degrees-of-freedom (DOFs) simultaneously, the sagittal and frontal planes. The characterization included important ankle properties unavailable from single DOF studies: coupling between DOFs and anisotropy as a function of frequency. Ankle impedance in joint coordinates showed responses largely consistent with a second-order system consisting of inertia, viscosity, and stiffness in both seated (knee flexed) and standing (knee straightened) postures. Stiffness in the sagittal plane was greater than in the frontal plane and furthermore, was greater when standing than when seated, most likely due to the stretch of bi-articular muscles (medial and lateral gastrocnemius). Very low off-diagonal partial coherences implied negligible coupling between dorsiflexion-plantarflexion and inversion-eversion. The directions of principal axes were tilted slightly counterclockwise from the original joint coordinates. The directional variation (anisotropy) of ankle impedance in the 2-D space formed by rotations in the sagittal and frontal planes exhibited a characteristic "peanut" shape, weak in inversion-eversion over a wide range of frequencies from the stiffness dominated region up to the inertia dominated region. Implications for the assessment of neurological and biomechanical impairments are discussed.

  13. Equivalent circuit models for interpreting impedance perturbation spectroscopy data

    NASA Astrophysics Data System (ADS)

    Smith, R. Lowell

    2004-07-01

    As in-situ structural integrity monitoring disciplines mature, there is a growing need to process sensor/actuator data efficiently in real time. Although smaller, faster embedded processors will contribute to this, it is also important to develop straightforward, robust methods to reduce the overall computational burden for practical applications of interest. This paper addresses the use of equivalent circuit modeling techniques for inferring structure attributes monitored using impedance perturbation spectroscopy. In pioneering work about ten years ago significant progress was associated with the development of simple impedance models derived from the piezoelectric equations. Using mathematical modeling tools currently available from research in ultrasonics and impedance spectroscopy is expected to provide additional synergistic benefits. For purposes of structural health monitoring the objective is to use impedance spectroscopy data to infer the physical condition of structures to which small piezoelectric actuators are bonded. Features of interest include stiffness changes, mass loading, and damping or mechanical losses. Equivalent circuit models are typically simple enough to facilitate the development of practical analytical models of the actuator-structure interaction. This type of parametric structure model allows raw impedance/admittance data to be interpreted optimally using standard multiple, nonlinear regression analysis. One potential long-term outcome is the possibility of cataloging measured viscoelastic properties of the mechanical subsystems of interest as simple lists of attributes and their statistical uncertainties, whose evolution can be followed in time. Equivalent circuit models are well suited for addressing calibration and self-consistency issues such as temperature corrections, Poisson mode coupling, and distributed relaxation processes.

  14. Gastrointestinal Impedance Spectroscopy to Detect Hypoperfusion During Hemorrhage.

    PubMed

    Bloch, Andreas; Kohler, Andreas; Posthaus, Horst; Berger, David; Santos, Laura; Jakob, Stephan; Takala, Jukka; Haenggi, Matthias

    2017-08-01

    Changes in tissue impedance (Ω) have been proposed as early signs of impaired tissue perfusion. We hypothesized that hemorrhage may induce early changes in alimentary tract tissue impedance and that these can be detected by impedance spectroscopy. We evaluated impedance spectroscopy in an acute hemorrhage model in pigs. Twenty anesthetized pigs were randomized to stepwise hemorrhage to mean arterial blood pressure (MAP) targets of 60 mm Hg, 50 mm Hg, 45 mm Hg, and 40 mm Hg, followed by retransfusion in two steps, or control (n = 10 each). In the end, 500 mL of enteral nutrition was administered in both groups. Ω in four sites (sublingually, esophagus, stomach, proximal jejunum) and cardiac output (Qtot thermodilution), superior mesenteric artery blood flow (QSMA; Doppler ultrasound), and jejunal mucosal blood flow (LDF; laser Doppler) were measured. The bleeding (total volume 838 ± 185 mL; mean ± SD) resulted in progressive hypotension (actual MAP 65 ± 3 mm Hg, 59 ± 4 mm Hg, 55 ± 5 mm Hg, and 46 ± 6 mm Hg) and decrease in Qtot, QSMA, and mucosal LDF. Bleeding did not change Ω in any of the monitoring sites. Retransfusion restored the blood flows to at least baseline levels, again without change in Ω. Enteral nutrition did not alter Ω or any of the blood flows.Five animals (three in the hemorrhage group, two in the control group) had histologically proven acute gastric focal necrosis at the site of It transducer. Gastrointestinal impedance spectroscopy does not detect early changes in tissue perfusion during progressive hemorrhage or retransfusion. Ω spectroscopy is unlikely to provide any additional information of hypovolemia-induced early changes in gastrointestinal perfusion.

  15. Non-Intrusive Impedance-Based Cable Tester

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    1999-01-01

    A non-intrusive electrical cable tester determines the nature and location of a discontinuity in a cable through application of an oscillating signal to one end of the cable. The frequency of the oscillating signal is varied in increments until a minimum, close to zero voltage is measured at a signal injection point which is indicative of a minimum impedance at that point. The frequency of the test signal at which the minimum impedance occurs is then employed to determine the distance to the discontinuity by employing a formula which relates this distance to the signal frequency and the velocity factor of the cable. A numerically controlled oscillator is provided to generate the oscillating signal, and a microcontroller automatically controls operation of the cable tester to make the desired measurements and display the results. The device is contained in a portable housing which may be hand held to facilitate convenient use of the device in difficult to access locations.

  16. TRANSVERSE IMPEDANCE OF THE SQUID GIANT AXON DURING CURRENT FLOW

    PubMed Central

    Cole, Kenneth S.; Baker, Richard F.

    1941-01-01

    The change in the transverse impedance of the squid giant axon caused by direct current flow has been measured at frequencies from 1 kc. per second to 500 kc. per second. The impedance change is equivalent to an increase of membrane conductance at the cathode to a maximum value approximately the same as that obtained during activity and a decrease at the anode to a minimum not far from zero. There is no evidence of appreciable membrane capacity change in either case. It then follows that the membrane has the electrical characteristics of a rectifier. Interpreting the membrane conductance as a measure of ion permeability, this permeability is increased at the cathode and decreased at the anode. PMID:19873233

  17. Dielectrophoresis and dielectrophoretic impedance detection of adenovirus and rotavirus

    NASA Astrophysics Data System (ADS)

    Nakano, Michihiko; Ding, Zhenhao; Suehiro, Junya

    2016-01-01

    The aim of this study is the electrical detection of pathogenic viruses, namely, adenovirus and rotavirus, using dielectrophoretic impedance measurement (DEPIM). DEPIM consists of two simultaneous processes: dielectrophoretic trapping of the target and measurement of the impedance change and increase in conductance with the number of trapped targets. This is the first study of applying DEPIM, which was originally developed to detect bacteria suspended in aqueous solutions, to virus detection. The dielectric properties of the viruses were also investigated in terms of their dielectrophoretic behavior. Although their estimated dielectric properties were different from those of bacteria, the trapped viruses increased the conductance of the microelectrode in a manner similar to that in bacteria detection. We demonstrated the electrical detection of viruses within 60 s at concentrations as low as 70 ng/ml for adenovirus and 50 ng/ml for rotavirus.

  18. Stochastic Estimation of Arm Mechanical Impedance During Robotic Stroke Rehabilitation

    PubMed Central

    Palazzolo, Jerome J.; Ferraro, Mark; Krebs, Hermano Igo; Lynch, Daniel; Volpe, Bruce T.; Hogan, Neville

    2009-01-01

    This paper presents a stochastic method to estimate the multijoint mechanical impedance of the human arm suitable for use in a clinical setting, e.g., with persons with stroke undergoing robotic rehabilitation for a paralyzed arm. In this context, special circumstances such as hypertonicity and tissue atrophy due to disuse of the hemiplegic limb must be considered. A low-impedance robot was used to bring the upper limb of a stroke patient to a test location, generate force perturbations, and measure the resulting motion. Methods were developed to compensate for input signal coupling at low frequencies apparently due to human–machine interaction dynamics. Data was analyzed by spectral procedures that make no assumption about model structure. The method was validated by measuring simple mechanical hardware and results from a patient's hemiplegic arm are presented. PMID:17436881

  19. Impedance matched joined drill pipe for improved acoustic transmission

    DOEpatents

    Moss, William C.

    2000-01-01

    An impedance matched jointed drill pipe for improved acoustic transmission. A passive means and method that maximizes the amplitude and minimize the temporal dispersion of acoustic signals that are sent through a drill string, for use in a measurement while drilling telemetry system. The improvement in signal transmission is accomplished by replacing the standard joints in a drill string with joints constructed of a material that is impedance matched acoustically to the end of the drill pipe to which it is connected. Provides improvement in the measurement while drilling technique which can be utilized for well logging, directional drilling, and drilling dynamics, as well as gamma-ray spectroscopy while drilling post shot boreholes, such as utilized in drilling post shot boreholes.

  20. Impedance Eduction in Sound Fields With Peripherally Varying Liners and Flow

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.

    2015-01-01

    A two-dimensional impedance eduction theory is extended to three-dimensional sound fields and peripherally varying duct liners. The approach is to first measure the acoustic pressure field at a series of flush-mounted wall microphones located around the periphery of the flow duct. The numerical solution for the acoustic pressure field at these microphones is also obtained by solving the three-dimensional convected Helmholtz equation using the finite element method. A quadratic objective function based on the difference between the measured and finite element solution is constructed and the unknown impedance function is obtained by minimizing this objective function. Impedance spectra educed for two uniform-structure liners (a wire-mesh and a conventional liner) and a hard-soft-hard peripherally varying liner (for which the soft segment is that of the conventional liner) are presented. Results are presented at three mean flow Mach numbers and fourteen sound source frequencies. The impedance spectra of the uniform-structure liners are also computed using a two-dimensional impedance eduction theory. The primary conclusions of the study are: 1) when measured data is used with the uniform-structure liners, the three-dimensional theory reproduces the same impedance spectra as the two-dimensional theory except for frequencies corresponding to very low or very high liner attenuation; and 2) good agreement between the educed impedance spectra of the uniform structure conventional liner and the soft segment of the peripherally varying liner is obtained.

  1. Note: Rapid offset reduction of impedance bridges taking into account instrumental damping and phase shifting.

    PubMed

    van der Wel, C M; Kortschot, R J; Bakelaar, I A; Erné, B H; Kuipers, B W M

    2013-03-01

    The sensitivity of an imperfectly balanced impedance bridge is limited by the remaining offset voltage. Here, we present a procedure for offset reduction in impedance measurements using a lock-in amplifier, by applying a complex compensating voltage external to the bridge. This procedure takes into account instrumental damping and phase shifting, which generally occur at the high end of the operational frequency range. Measurements demonstrate that the output of the circuit rapidly converges to the instrumentally limited noise at any frequency.

  2. Electrokinetics Models for Micro and Nano Fluidic Impedance Sensors

    DTIC Science & Technology

    2010-11-01

    primitive Differential-Algebraic Equations (DAEs), used to process and interpret the experimentally measured electrical impedance data (Sun and Morgan...field, and species respectively. A second-order scheme was used to calculate the ionic species distribution. The linearized algebraic equations were...is governed by the Poisson equation 2 0 0 r i i i F z cε ε φ∇ + =∑ where ε0 and εr are, respectively, the electrical permittivity in the vacuum

  3. Impedance spectroscopy of reduced monoclinic zirconia.

    PubMed

    Eder, Dominik; Kramer, Reinhard

    2006-10-14

    Zirconia doped with low-valent cations (e.g. Y3+ or Ca2+) exhibits an exceptionally high ionic conductivity, making them ideal candidates for various electrochemical applications including solid oxide fuel cells (SOFC) and oxygen sensors. It is nevertheless important to study the undoped, monoclinic ZrO2 as a model system to construct a comprehensive picture of the electrical behaviour. In pure zirconia a residual number of anion vacancies remains because of contaminants in the material as well as the thermodynamic disorder equilibrium, but electronic conduction may also contribute to the observed conductivity. Reduction of zirconia in hydrogen leads to the adsorption of hydrogen and to the formation of oxygen vacancies, with their concentration affected by various parameters (e.g. reduction temperature and time, surface area, and water vapour pressure). However, there is still little known about the reactivities of defect species and their effect on the ionic and electronic conduction. Thus, we applied electrochemical impedance spectroscopy to investigate the electric performance of pure monoclinic zirconia with different surface areas in both oxidizing and reducing atmospheres. A novel equivalent circuit model including parallel ionic and electronic conduction has previously been developed for titania and is used herein to decouple the conduction processes. The concentration of defects and their formation energies were measured using volumetric oxygen titration and temperature programmed oxidation/desorption.

  4. Note: Characterization and test of a high input impedance RF amplifier for series nanowire detector

    NASA Astrophysics Data System (ADS)

    Wan, Chao; Pei, Yufeng; Jiang, Zhou; Kang, Lin; Wu, Peiheng

    2016-09-01

    We designed a high input impedance RF amplifier based on Tower Jazz's 0.18 μm SiGe BiCMOS process for series nanowire detector. The characterization of its gain and input impedance with a vector network analyzer is described in detail for its specificity. The actual 15 dB gain should be the measured value subtracts 6 dB, which is easy to be ignored. Its input impedance can be equivalent to 6.7 kΩ ∥ 3.4 pF though fitting the measurement, whose accuracy is verified. The process of measurement provides a good reference to characterize the similar special amplifier with unmatched impedance.

  5. Impedance study of undoped, polycrystalline diamond layers obtained by HF CVD

    NASA Astrophysics Data System (ADS)

    Paprocki, Kazimierz; Fabisiak, Kazimerz; Dychalska, Anna; Szybowicz, Mirosław; Dudkowiak, Alina; Iskaliyeva, Aizhan

    2017-04-01

    In this paper, we report results of impedance measurements in polycrystalline diamond films deposited on n-Si using HF CVD method. The temperature was changed from 170 K up to RT and the scan frequency from 42 Hz to 5 MHz. The results of impedance measurement of the real and imaginary parts were presented in the form of a Cole-Cole plot in the complex plane. In the temperatures below RT, the observed impedance response of polycrystalline diamond was in the form of a single semicircular form. In order to interpret the observed response, a double resistor-capacitor parallel circuit model was used which allow for interpretation physical mechanisms responsible for such behavior. The impedance results were correlated with Raman spectroscopy measurements.

  6. Comparison of bolus transit patterns identified by esophageal impedance to barium esophagram in patients with dysphagia.

    PubMed

    Cho, Y K; Choi, M-G; Oh, S N; Baik, C N; Park, J M; Lee, I S; Kim, S W; Choi, K Y; Chung, I-S

    2012-01-01

    Bolus transit through the esophagus has not been validated by videoesophagram in patients with dysphagia and changes in impedance with abnormal barium transit have not been described in those patients. The aim of this study was to compare esophageal impedance findings with barium esophagram measurements in patients with dysphagia. The consecutive patients with dysphagia underwent conventional multichannel esophageal impedance manometry, after which a barium videoesophagram was performed simultaneously with multichannel esophageal impedance manometry using a mean of three swallows of barium. Esophageal emptying patterns shown in the esophagogram were classified by the degree of intraesophageal stasis and presence of intraesophageal reflux. Bolus transit patterns in impedance were classified as complete and incomplete transit. Sixteen patients (M : F = 8 : 8, mean age, 47 years) were enrolled. Their manometric diagnosis were normal (n= 6), ineffective esophageal motility (n= 1), diffuse esophageal spasm (DES; n= 2), and achalasia (n= 7). Sixty-three swallows were analyzed. According to impedance analysis, 21/22 swallows with normal barium emptying showed complete transit (96%) and 31/32 swallows with severe stasis showed incomplete transit (97%). Nine swallows with mild stasis showed either complete or incomplete transit patterns in impedance. Swallows with mild barium stasis and complete transit in impedance were observed in patients who had received treatment (two patients with achalasia with history of esophageal balloonplasty and a patient with DES after nifedipine administration). Impedance reflected severe stasis with retrograde barium movement and described typical bolus transit patterns in patients with achalasia and DES. In conclusion, impedance-barium esophagram concordance is high for swallows with normal esophageal emptying and for severe barium stasis in patients with dysphagia. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley

  7. Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium.

    PubMed

    Yang, Liju; Li, Yanbin; Griffis, Carl L; Johnson, Michael G

    2004-05-15

    Interdigitated microelectrodes (IMEs) were used as impedance sensors for rapid detection of viable Salmonella typhimurium in a selective medium and milk samples. The impedance growth curves, impedance against bacterial growth time, were recorded at four frequencies (10Hz, 100Hz, 1kHz, and 10kHz) during the growth of S. typhimurium. The impedance did not change until the cell number reached 10(5)-10(6) CFUml(-1). The greatest change in impedance was observed at 10Hz. To better understand the mechanism of the IME impedance sensor, an equivalent electrical circuit, consisting of double layer capacitors, a dielectric capacitor, and a medium resistor, was introduced and used for interpreting the change in impedance during bacterial growth. Bacterial attachment to the electrode surface was observed with scanning electron microscopy, and it had effect on the impedance measurement. The detection time, t(D), defined as the time for the impedance to start change, was obtained from the impedance growth curve at 10Hz and had a linear relationship with the logarithmic value of the initial cell number of S. typhimurium in the medium and milk samples. The regression equations for the cell numbers between 4.8 and 5.4 x 10(5) CFUml(-1) were t(D) = -1.38 log N + 10.18 with R(2) = 0.99 in the pure medium and t(D) = -1.54 log N + 11.33 with R(2) = 0.98 in milk samples, respectively. The detection times for 4.8 and 5.4 x 10(5) CFUml(-1) initial cell numbers were 9.3 and 2.2 h, respectively, and the detection limit could be as low as 1 cell in a sample.

  8. A new hybrid active/passive sound absorber with variable surface impedance

    NASA Astrophysics Data System (ADS)

    Betgen, Benjamin; Galland, Marie-Annick

    2011-07-01

    The context of the present paper is the wall treatment of flow ducts, notably aero-engine nacelle intakes and outlets. For this purpose, hybrid active/passive absorbers have been developed at the LMFA for about 15 years. A hybrid cell combines passive absorbent properties of a porous layer and active control at its rear face. Active control is mainly used to increase absorption at low frequencies by cancelling the imaginary part of the surface impedance presented by the absorber. However, the optimal impedance (i.e. the one that produces the highest noise reduction) of an absorber for flow duct applications is generally complex and frequency dependent. A new hybrid absorber intended to realise any of impedance has therefore been developed. The new cell uses one microphone on each side of a resistive cloth. Normal velocity can then be deduced by a simple pressure difference, which allows an estimation of the surface impedance of the absorber. In order to obtain an error signal related to a target impedance, the target impedance has to be reproduced in time domain. The design of a stable and causal filter is a difficult task, considering the kind of frequency response we seek. An alternative way of representing the impedance in time domain is therefore given. The new error signal is integrated into a feedback control structure. Fast convergence and good stability are observed for a wide range of target impedances. Typical optimal impedances with a positive increasing real part and a negative decreasing imaginary part have been successfully realised. Measurements in a grazing-incidence tube show that the new complex impedance absorber clearly outperforms the former active absorber.

  9. Evaluation of Wall Boundary Conditions for Impedance Eduction Using a Dual-Source Method

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.

    2012-01-01

    The accuracy of the Ingard-Myers boundary condition and a recently proposed modified Ingard-Myers boundary condition is evaluated for use in impedance eduction under the assumption of uniform mean flow. The evaluation is performed at three centerline Mach numbers, using data acquired in a grazing flow impedance tube, using both upstream and downstream propagating sound sources, and on a database of test liners for which the expected behavior of the impedance spectra is known. The test liners are a hard-wall insert consisting of 12.6 mm thick aluminum, a linear liner without a facesheet consisting of a number of small diameter but long cylindrical channels embedded in a ceramic material, and two conventional nonlinear liners consisting of a perforated facesheet bonded to a honeycomb core. The study is restricted to a frequency range for which only plane waves are cut on in the hard-wall sections of the flow impedance tube. The metrics used to evaluate each boundary condition are 1) how well it educes the same impedance for upstream and downstream propagating sources, and 2) how well it predicts the expected behavior of the impedance spectra over the Mach number range. The primary conclusions of the study are that the same impedance is educed for upstream and downstream propagating sources except at the highest Mach number, that an effective impedance based on both the upstream and downstream measurements is more accurate than an impedance based on the upstream or downstream data alone, and that the Ingard-Myers boundary condition with an effective impedance produces results similar to that achieved with the modified Ingard-Myers boundary condition.

  10. Noninvasive electrical impedance sensor for in vivo tissue discrimination at radio frequencies.

    PubMed

    Dai, Yu; Du, Jun; Yang, Qing; Zhang, Jianxun

    2014-09-01

    Compared to traditional open surgery, minimally invasive surgery (MIS) allows for a more rapid and less painful recovery. However, the lack of significant haptic feedback in MIS can make tissue discrimination difficult. This paper tests a noninvasive electrical impedance sensor for in vivo discrimination of tissue types in MIS. The sensor consists of two stainless steel spherical electrodes used to measure the impedance spectra over the frequency range of 200 kHz to 5 MHz. The sensor helps ensure free movement on an organ surface and prevents soft tissues from being injured during impedance measurement. Since the recorded electrical impedance is correlated with the force pressed on the electrode and the mechanical property of the tissue, the electrode-tissue contact impedance is calculated theoretically. We show that the standard deviation of the impedance ratio at each frequency point is sufficient to distinguish different tissue types. Both in vitro experiment in a pig kidney and in vivo experiment in rabbit organs were performed to demonstrate the feasibility of the electrical impedance sensor. The experimental results indicated that the sensor, used with the proposed data-processing method, provides accurate and reliable biological tissue discrimination. © 2014 Wiley Periodicals, Inc.

  11. Impedance microflow cytometry for viability studies of microorganisms

    NASA Astrophysics Data System (ADS)

    Di Berardino, Marco; Hebeisen, Monika; Hessler, Thomas; Ziswiler, Adrian; Largiadèr, Stephanie; Schade, Grit

    2011-02-01

    Impedance-based Coulter counters and its derivatives are widely used cell analysis tools in many laboratories and use normally DC or low frequency AC to perform these electrical analyses. The emergence of micro-fabrication technologies in the last decade, however, provides a new means of measuring electrical properties of cells. Microfluidic approaches combined with impedance spectroscopy measurements in the radio frequency (RF) range increase sensitivity and information content and thus push single cell analyses beyond simple cell counting and sizing applications towards multiparametric cell characterization. Promising results have been shown already in the fields of cell differentiation and blood analysis. Here we emphasize the potential of this technology by presenting new data obtained from viability studies on microorganisms. Impedance measurements of several yeast and bacteria strains performed at frequencies around 10 MHz enable an easy discrimination between dead and viable cells. Moreover, cytotoxic effects of antibiotics and other reagents, as well as cell starvation can also be monitored easily. Control analyses performed with conventional flow cytometers using various fluorescent dyes (propidium iodide, oxonol) indicate a good correlation and further highlight the capability of this device. The label-free approach makes on the one hand the use of usually expensive fluorochromes obsolete, on the other hand practically eliminates laborious sample preparation procedures. Until now, online cell monitoring was limited to the determination of viable biomass, which provides rather poor information of a cell culture. Impedance microflow cytometry, besides other aspects, proposes a simple solution to these limitations and might become an important tool for bioprocess monitoring applications in the biotech industry.

  12. Vertical electrical impedance evaluation of asphalt overlays on concrete bridge decks

    NASA Astrophysics Data System (ADS)

    Baxter, Jared S.; Guthrie, W. Spencer; Waters, Tenli; Barton, Jeffrey D.; Mazzeo, Brian A.

    2018-04-01

    Vertical electrical impedance scanning of concrete bridge decks is a non-destructive method for quantifying the degree of protection provided to steel reinforcement against the ingress of corrosive agents. Four concrete bridge decks with asphalt overlays in northern Utah were evaluated using scanning vertical electrical impedance measurements in this study. At the time of testing, the bridges ranged in age from 21 to 34 years, and asphalt overlays had been in place for 7 to 22 years, depending on the bridge. Electrical impedance measurements were collected using a previously constructed apparatus that consisted of six probes spanning a transverse distance of 12 ft. The impedance measurements were compared to surface cracking observations and cores obtained from the same four bridge decks. The results presented in this paper demonstrate the utility of scanning vertical electrical impedance measurements for detecting cracks in asphalt overlays and quantifying their severity. In addition, the results demonstrate the sensitivity of impedance measurements to the presence of an intact membrane beneath the asphalt overlay.

  13. Stochastic estimation of human shoulder impedance with robots: an experimental design.

    PubMed

    Park, Kyungbin; Chang, Pyung Hun

    2011-01-01

    Previous studies assumed the shoulder as a hinge joint during human arm impedance measurement. This is obviously a vast simplification since the shoulder is a complex of several joints with multiple degrees of freedom. In the present work, a practical methodology for more general and realistic estimation of human shoulder impedance is proposed and validated with a spring array. It includes a gravity compensation scheme, which is developed and used for the experiments with a spatial three degrees of freedom PUMA-type robot. The experimental results were accurate and reliable, and thus it has shown a strong potential of the proposed methodology in the estimation of human shoulder impedance. © 2011 IEEE

  14. Impedance-matching system for a flexible surface-coil-type resonator

    NASA Astrophysics Data System (ADS)

    Hirata, Hiroshi; Ono, Mitsuhiro

    1997-09-01

    This article describes an impedance-matching system for a flexible surface-coil-type resonator (FSCR) used in electron paramagnetic resonance (EPR) experiments. To design the matching system, the input impedance of the FSCR was formulated using transmission line theory, and then the parameters of a matching circuit using varicap diodes were calculated. Experimental measurements of input impedance showed the validity of the formulation and the usefulness of the matching system. The matching circuit made by the varicap diodes 1SV186 offered the tunable bandwidth of 50 MHz for the prototype FSCR. Such a matching system also offers the possibility of remotely tuning EPR resonators electronically.

  15. Cell-substrate impedance fluctuations of single amoeboid cells encode cell-shape and adhesion dynamics

    NASA Astrophysics Data System (ADS)

    Leonhardt, Helmar; Gerhardt, Matthias; Höppner, Nadine; Krüger, Kirsten; Tarantola, Marco; Beta, Carsten

    2016-01-01

    We show systematic electrical impedance measurements of single motile cells on microelectrodes. Wild-type cells and mutant strains were studied that differ in their cell-substrate adhesion strength. We recorded the projected cell area by time-lapse microscopy and observed irregular oscillations of the cell shape. These oscillations were correlated with long-term variations in the impedance signal. Superposed to these long-term trends, we observed fluctuations in the impedance signal. Their magnitude clearly correlated with the adhesion strength, suggesting that strongly adherent cells display more dynamic cell-substrate interactions.

  16. Qualitative human body composition analysis assessed with bioelectrical impedance.

    PubMed

    Talluri, T

    1998-12-01

    Body composition is generally aiming at quantitative estimates of fat mass, inadequate to assess nutritional states that on the other hand are well defined by the intra/extra cellular masses proportion (ECM/BCM). Direct measures performed with phase sensitive bioelectrical impedance analyzers can be used to define the current distribution in normal and abnormal populations. Phase angle and reactance nomogram is directly reflecting the ECM/BCM pathways proportions and body impedance analysis (BIA) is also validated to estimate the individual content of body cell mass (BCM). A new body cell mass index (BCMI) obtained dividing the weight of BCM in kilograms by the body surface in square meters is confronted to the scatterplot distribution of phase angle and reactance values obtained from controls and patients, and proposed as a qualitative approach to identify abnormal ECM/BCM ratios and nutritional states.

  17. Impedance-based cellular assay technologies: recent advances, future promise.

    PubMed

    McGuinness, Ryan

    2007-10-01

    Cell-based assays are continuing to grow in importance in the drug discovery workflow. Their early introduction holds the promise of limiting attrition in the later, more costly phases of the process. This article reviews recent advances in the development of impedance technologies for label-free cell-based assays. These systems are capable of monitoring endogenous receptor activation, and thus generate more physiologically relevant measures of pharmacological endpoints. Primary cells can be investigated as well, thus producing disease relevant information. Label-free assays significantly decrease assay development efforts and avoid many complications inherent in recombinant readout systems. Impedance-based systems have great potential to advance the utility of cell-based assays as they are applied to drug discovery and pharmacology.

  18. Experimental Impedance of Single Liner Elements with Bias Flow

    NASA Technical Reports Server (NTRS)

    Follet, J. I.; Betts, J. F.; Kelly, Jeffrey J.; Thomas, Russell H.

    2000-01-01

    An experimental investigation was conducted to generate a high quality database, from which the effects of a mean bias flow on the acoustic impedance of lumped-element single-degree-of-freedom liners was determined. Acoustic impedance measurements were made using the standard two-microphone method in the NASA Langley Normal Incidence Tube. Each liner consisted of a perforated sheet with a constant-area cavity. Liner resistance was shown to increase and to become less frequency and sound pressure level dependent as the bias flow was increased. The resistance was also consistently lower for a negative bias flow (suction) than for a positive bias flow (blowing) of equal magnitude. The slope of the liner reactance decreased with increased flow.

  19. Determining bonding, thickness, and density via thermal wave impedance NDE

    NASA Technical Reports Server (NTRS)

    Green, D. R.

    1985-01-01

    Bonding, density, and thickness of coatings have a vital effect on their performance in many applications. Pioneering development work on thermal wave nondestructive evaluation (NDE) methods during the past 25 years has resulted in an array of useful techniques for performing bonding, density, and thickness measurements in a practical shop environment. The most useful thermal wave methods for this purpose are based on thermal wave surface impedance measurement or scanning. A pulse of heat from either a thermal transducer or a hot gas pulse is projected onto the surface, and the resulting temperature response is analyzed to unfold the bonding, density, and thickness of the coating. An advanced emissivity independent infrared method was applied to detect the temperature response. These methods were recently completely computerized and can automatically provide information on coating quality in near real-time using the proper equipment. Complex shapes such as turbine blades can be scanned. Microscopic inhomogeneities such as microstructural differences and small, normal, isolated voids do not cause problems but are seen as slight differences in the bulk thermal properties. Test objects with rough surfaces can be effectively nondestructively evaluated using proper thermal surface impedance methods. Some of the basic principles involved, as well as metallographic results illustrating the ability of the thermal wave surface impedance method to detect natural nonbonds under a two-layer thermally sprayed coating, will be presented.

  20. The IMPACT shirt: textile integrated and portable impedance cardiography.

    PubMed

    Ulbrich, Mark; Mühlsteff, Jens; Sipilä, Auli; Kamppi, Merja; Koskela, Anne; Myry, Manu; Wan, Tingting; Leonhardt, Steffen; Walter, Marian

    2014-06-01

    Measurement of hemodynamic parameters such as stroke volume (SV) via impedance cardiography (ICG) is an easy, non-invasive and inexpensive way to assess the health status of the heart. We present a possibility to use this technology for monitoring risk patients at home. The IMPACT Shirt (IMPedAnce Cardiography Textile) has been developed with integrated textile electrodes and textile wiring, as well as with portable miniaturized hardware. Several textile materials were characterized in vitro and in vivo to analyze their performance with regard to washability, and electrical characteristics such as skin-electrode impedance, capacitive coupling and subjective tactile feeling. The small lightweight hardware measures ECG and ICG continuously and transmits wireless data via Bluetooth to a mobile phone (Android) or PC for further analysis. A lithium polymer battery supplies the circuit and can be charged via a micro-USB. Results of a proof-of-concept trial show excellent agreement between SV assessed by a commercial device and the developed system. The IMPACT Shirt allows monitoring of SV and ECG on a daily basis at the patient's home.

  1. ONERA-NASA Cooperative Effort on Liner Impedance Eduction

    NASA Technical Reports Server (NTRS)

    Primus, Julien; Piot, Estelle; Simon, Frank; Jones, Michael G.; Watson, Willie R

    2013-01-01

    As part of a cooperation between ONERA and NASA, the liner impedance eduction methods developed by the two research centers are compared. The NASA technique relies on an objective function built on acoustic pressure measurements located on the wall opposite the test liner, and the propagation code solves the convected Helmholtz equation in uniform ow using a finite element method that implements a continuous Galerkin discretization. The ONERA method uses an objective function based either on wall acoustic pressure or on acoustic velocity acquired above the liner by Laser Doppler Anemometry, and the propagation code solves the linearized Euler equations by a discontinuous Galerkin discretization. Two acoustic liners are tested in both ONERA and NASA ow ducts and the measured data are treated with the corresponding impedance eduction method. The first liner is a wire mesh facesheet mounted onto a honeycomb core, designed to be linear with respect to incident sound pressure level and to grazing ow velocity. The second one is a conventional, nonlinear, perforate-over-honeycomb single layer liner. Configurations without and with ow are considered. For the nonlinear liner, the comparison of liner impedance educed by NASA and ONERA shows a sensitivity to the experimental conditions, namely to the nature of the source and to the sample width.

  2. Electrical impedance tomography spectroscopy method for characterising particles in solid-liquid phase

    SciTech Connect

    Zhao, Yanlin; Wang, Mi; Yao, Jun

    2014-04-11

    Electrical impedance tomography (EIT) is one of the process tomography techniques to provide an on-line non-invasive imaging for multiphase flow measurement. With EIT measurements, the images of impedance real part, impedance imaginary part, phase angle, and magnitude can be obtained. However, most of the applications of EIT in the process industries rely on the conductivity difference between two phases in fluids to obtain the concentration profiles. It is not common to use the imaginary part or phase angle due to the dominant change in conductivity or complication in the use of other impedance information. In a solid-liquid two phases systemmore » involving nano- or submicro-particles, characterisation of particles (e.g. particle size and concentration) have to rely on the measurement of impedance phase angle or imaginary part. Particles in a solution usually have an electrical double layer associated with their surfaces and can form an induced electrical dipole moment due to the polarization of the electrical double layer under the influence of an alternating electric field. Similar to EIT, electrical impedance spectroscopy (EIS) measurement can record the electrical impedance data, including impedance real part, imaginary part and phase angle (θ), which are caused by the polarization of the electrical double layer. These impedance data are related to the particle characteristics e.g. particle size, particle and ionic concentrations in the aqueous medium, therefore EIS method provides a capability for characterising the particles in suspensions. Electrical impedance tomography based on EIS measurement or namely, electrical impedance tomography spectroscopy (EITS) could image the spatial distribution of particle characteristics. In this paper, a new method, including test set-up and data analysis, for characterisation of particles in suspensions are developed through the experimental approach. The experimental results on tomographic imaging of colloidal

  3. Earth impedance model for through-the-earth communication applications with electrodes

    NASA Astrophysics Data System (ADS)

    Bataller, Vanessa; MuñOz, Antonio; Gaudó, Pilar Molina; Mediano, Arturo; Cuchí, José A.; Villarroel, José L.

    2010-12-01

    Through-the-earth (TTE) communications are relevant in applications such as caving, tunnel and cave rescue, mining, and subsurface radiolocation. The majority of the TTE communication systems use ground electrodes as load antenna. Wires, electrode contact, and earth impedances are the major contributors to the impedance observed by the transmitter. In this paper, state-of-art models found in the literature are reviewed, and an improved method to measure the earth impedance is presented. The paper also proposes an optimal circuit model for earth impedance between electrodes as a function of frequency, as a consequence of the particular conditions of the application. The model is validated with measurements for different soil conditions, showing a good agreement between empirical data and the simulation results.

  4. Duct wall impedance control as an advanced concept for acoustic suppression enhancement. [engine noise reduction

    NASA Technical Reports Server (NTRS)

    Dean, P. D.

    1978-01-01

    A systems concept procedure is described for the optimization of acoustic duct liner design for both uniform and multisegment types. The concept was implemented by the use of a double reverberant chamber flow duct facility coupled with sophisticated computer control and acoustic analysis systems. The optimization procedure for liner insertion loss was based on the concept of variable liner impedance produced by bias air flow through a multilayer, resonant cavity liner. A multiple microphone technique for in situ wall impedance measurements was used and successfully adapted to produce automated measurements for all liner configurations tested. The complete validation of the systems concept was prevented by the inability to optimize the insertion loss using bias flow induced wall impedance changes. This inability appeared to be a direct function of the presence of a higher order energy carrying modes which were not influenced significantly by the wall impedance changes.

  5. Tunable impedance matching network fundamental limits and practical considerations

    NASA Astrophysics Data System (ADS)

    Allen, Wesley N.

    As wireless devices continue to increase in utility while decreasing in dimension, design of the RF front-end becomes more complex. It is common for a single handheld device to operate on a plethora of frequency bands, utilize multiple antennae, and be subjected to a variety of environments. One complexity in particular which arises from these factors is that of impedance mismatch. Recently, tunable impedance matching networks have begun to be implemented to address this problem. This dissertation presents the first in-depth study on the frequency tuning range of tunable impedance matching networks. Both the fundamental limitations of ideal networks as well as practical considerations for design and implementation are addressed. Specifically, distributed matching networks with a single tuning element are investigated for use with parallel resistor-capacitor and series resistor-inductor loads. Analytical formulas are developed to directly calculate the frequency tuning range TR of ideal topologies. The theoretical limit of TR for these topologies is presented and discussed. Additional formulas are developed which address limitations in transmission line characteristic impedance and varactor range. Equations to predict loss due to varactor quality factor are demonstrated and the ability of parasitics to both increase and decrease TR are shown. Measured results exemplify i) the potential to develop matching networks with a small impact from parasitics, ii) the need for accurate knowledge of parasitics when designing near transition points in optimal parameters, iii) the importance of using a transmission line with the right characteristic impedance, and iv) the ability to achieve extremely low loss at the design frequency with a lossy varactor under the right conditions (measured loss of -0.07 dB). In the area of application, tunable matching networks are designed and measured for mobile handset antennas, demonstrating up to a 3 dB improvement in power delivered to a

  6. A Comparative Study of Four Impedance Eduction Methodologies Using Several Test Liners

    NASA Technical Reports Server (NTRS)

    Watson, Willie R.; Jones, Michael G.

    2013-01-01

    A comparative study of four commonly used impedance eduction methods is presented for a range of liner structures and test conditions. Two of the methods are restricted to uniform flow while the other two accommodate both uniform and boundary layer flows. Measurements on five liner structures (a rigid-wall insert, a ceramic tubular liner, a wire mesh liner, a low porosity conventional liner, and a high porosity conventional liner) are obtained using the NASA Langley Grazing Flow Impedance Tube. The educed impedance of each liner is presented for forty-two test conditions (three Mach numbers and fourteen frequencies). In addition, the effects of moving the acoustic source from upstream to downstream and the refractive effects of the mean boundary layer on the wire mesh liner are investigated. The primary conclusions of the study are that: (1) more accurate results are obtained for the upstream source, (2) the uniform flow methods produce nearly identical impedance spectra at and below Mach 0.3 but significant scatter in the educed impedance occurs at the higher Mach number, (3) there is better agreement in educed impedance among the methods for the conventional liners than for the rigid-wall insert, ceramic, or wire mesh liner, and (4) the refractive effects of the mean boundary layer on the educed impedance of the wire mesh liner are generally small except at Mach 0.5.

  7. Effects of Liner Length and Attenuation on NASA Langley Impedance Eduction

    NASA Technical Reports Server (NTRS)

    Jones, M. G.; Watson, W. R.

    2016-01-01

    This study explores the effects of liner length and attenuation on the CHE (convected Helmholtz equation) impedance eduction method, in which the surface impedance of an acoustic liner is inferred through an iterative process based on repeated solutions to the convected Helmholtz equation. Wire mesh-over-honeycomb and perforate-over-honeycomb acoustic liners are tested in the NASA Langley Grazing Flow Impedance Tube, and the resultant data are processed using two impedance eduction methods. The first is the CHE method, and the second is a direct method (labeled the KT method) that uses the Kumaresan and Tufts algorithm to compute the impedance directly. The CHE method has been extensively used for acoustic liner evaluation, but experiences anomalous behavior under some test conditions. It is postulated that the anomalies are related to the liner length and/or attenuation. Since the KT method only employs data measured over the length of the liner, it is expected to be unaffected by liner length. A comparison of results achieved with the two impedance eduction methods is used to explore the interactive effects of liner length and attenuation on the CHE impedance eduction method.

  8. Acoustic Treatment Design Scaling Methods. Volume 2; Advanced Treatment Impedance Models for High Frequency Ranges

    NASA Technical Reports Server (NTRS)

    Kraft, R. E.; Yu, J.; Kwan, H. W.

    1999-01-01

    The primary purpose of this study is to develop improved models for the acoustic impedance of treatment panels at high frequencies, for application to subscale treatment designs. Effects that cause significant deviation of the impedance from simple geometric scaling are examined in detail, an improved high-frequency impedance model is developed, and the improved model is correlated with high-frequency impedance measurements. Only single-degree-of-freedom honeycomb sandwich resonator panels with either perforated sheet or "linear" wiremesh faceplates are considered. The objective is to understand those effects that cause the simple single-degree-of- freedom resonator panels to deviate at the higher-scaled frequency from the impedance that would be obtained at the corresponding full-scale frequency. This will allow the subscale panel to be designed to achieve a specified impedance spectrum over at least a limited range of frequencies. An advanced impedance prediction model has been developed that accounts for some of the known effects at high frequency that have previously been ignored as a small source of error for full-scale frequency ranges.

  9. Adaptive Filtering to Enhance Noise Immunity of Impedance and Admittance Spectroscopy: Comparison with Fourier Transformation

    NASA Astrophysics Data System (ADS)

    Stupin, Daniil D.; Koniakhin, Sergei V.; Verlov, Nikolay A.; Dubina, Michael V.

    2017-05-01

    The time-domain technique for impedance spectroscopy consists of computing the excitation voltage and current response Fourier images by fast or discrete Fourier transformation and calculating their relation. Here we propose an alternative method for excitation voltage and current response processing for deriving a system impedance spectrum based on a fast and flexible adaptive filtering method. We show the equivalence between the problem of adaptive filter learning and deriving the system impedance spectrum. To be specific, we express the impedance via the adaptive filter weight coefficients. The noise-canceling property of adaptive filtering is also justified. Using the RLC circuit as a model system, we experimentally show that adaptive filtering yields correct admittance spectra and elements ratings in the high-noise conditions when the Fourier-transform technique fails. Providing the additional sensitivity of impedance spectroscopy, adaptive filtering can be applied to otherwise impossible-to-interpret time-domain impedance data. The advantages of adaptive filtering are justified with practical living-cell impedance measurements.

  10. Quantum optics in a high impedance environment

    NASA Astrophysics Data System (ADS)

    Puertas, Javier; Gheeraert, Nicolas; Krupko, Yuriy; Dassonneville, Remy; Planat, Luca; Foroughui, Farshad; Naud, Cecile; Guichard, Wiebke; Buisson, Olivier; Florens, Serge; Roch, Nicolas; Snyman, Izak

    Understanding light matter interaction remains a key topic in fundamental physics. Its strength is imposed by the fine structure constant, α. For most atomic and molecular systems α =e2/ℏc 4 πɛo = 1 / 137 << 1 , giving weak interactions. When dealing with superconducting artificial atoms, α is either proportional to 1 /Zc (magnetic coupling) or Zc (electric coupling), where Zc is the characteristic impedance of the environment. Recent experiments followed the first approach, coupling a flux qubit to a low impedance environment, demonstrating strong interaction (α 1). In our work, we reached the large α regime, following a complementary approach: we couple electrically a transmon qubit to an array of 5000 SQUIDs. This metamaterial provides high characteristic impedance ( 3 kΩ), in-situ flux tunability and full control over its dispersion relation. In this new regime, all usual approximations break down and new phenomena such as frequency conversion at the single photon level are expected.

  11. Impedance properties of circular microstrip antenna

    NASA Technical Reports Server (NTRS)

    Deshpande, M. D.; Bailey, M. C.

    1983-01-01

    A moment method solution to the input impedance of a circular microstrip antenna excited by either a microstrip feed or a coaxial probe is presented. Using the exact dyadic Green's function and the Fourier transform the problem is formulated in terms of Richmond's reaction integral equation from which the unknown patch current can be solved for. The patch current is expanded in terms of regular surface patch modes and an attachment mode (for probe excited case) which insures continuity of the current at probe/patch junction, proper polarization and p-dependance of patch current in the vicinity of the probe. The input impedance of a circular microstrip antenna is computed and compared with earlier results. Effect of attachment mode on the input impedance is also discussed.

  12. Wavelet analysis of the impedance cardiogram waveforms

    NASA Astrophysics Data System (ADS)

    Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.

    2012-12-01

    Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.

  13. Assessing heat treatment of chicken breast cuts by impedance spectroscopy.

    PubMed

    Schmidt, Franciny C; Fuentes, Ana; Masot, Rafael; Alcañiz, Miguel; Laurindo, João B; Barat, José M

    2017-03-01

    The aim of this work was to develop a new system based on impedance spectroscopy to assess the heat treatment of previously cooked chicken meat by two experiments; in the first, samples were cooked at different temperatures (from 60 to 90 ℃) until core temperature of the meat reached the water bath temperature. In the second approach, temperature was 80 ℃ and the samples were cooked for different times (from 5 to 55 min). Impedance was measured once samples had cooled. The examined processing parameters were the maximum temperature reached in thermal centre of the samples, weight loss, moisture and the integral of the temperature profile during the cooking-cooling process. The correlation between the processing parameters and impedance was studied by partial least square regressions. The models were able to predict the studied parameters. Our results are essential for developing a new system to control the technological, sensory and safety aspects of cooked meat products on the whole meat processing line.

  14. Estimation of fatigue life using electromechanical impedance technique

    NASA Astrophysics Data System (ADS)

    Lim, Yee Yan; Soh, Chee Kiong

    2010-04-01

    Fatigue induced damage is often progressive and gradual in nature. Structures subjected to large number of fatigue load cycles will encounter the process of progressive crack initiation, propagation and finally fracture. Monitoring of structural health, especially for the critical components, is therefore essential for early detection of potential harmful crack. Recent advent of smart materials such as piezo-impedance transducer adopting the electromechanical impedance (EMI) technique and wave propagation technique are well proven to be effective in incipient damage detection and characterization. Exceptional advantages such as autonomous, real-time and online, remote monitoring may provide a cost-effective alternative to the conventional structural health monitoring (SHM) techniques. In this study, the main focus is to investigate the feasibility of characterizing a propagating fatigue crack in a structure using the EMI technique as well as estimating its remaining fatigue life using the linear elastic fracture mechanics (LEFM) approach. Uniaxial cyclic tensile load is applied on a lab-sized aluminum beam up to failure. Progressive shift in admittance signatures measured by the piezo-impedance transducer (PZT patch) corresponding to increase of loading cycles reflects effectiveness of the EMI technique in tracing the process of fatigue damage progression. With the use of LEFM, prediction of the remaining life of the structure at different cycles of loading is possible.

  15. Impedance cardiography: What is the source of the signal?

    NASA Astrophysics Data System (ADS)

    Patterson, R. P.

    2010-04-01

    Impedance cardiography continues to be investigated for various applications. Instruments for its use are available commercially. Almost all of the recent presentations and articles along with commercial advertisements have assumed that aortic volume pulsation is the source of the signal. A review of the literature will reveal that there is no clear evidence for this assumption. Starting with the first paper on impedance cardiography in 1964, which assumed the lung was the source of the signal, the presentation will review many studies in the 60's, 70's and 80's, which suggest the aorta and other vessels as well as atria and again the lung as possible sources. Current studies based on high resolution thoracic models will be presented that show the aorta as contributing only approximately 1% of the total impedance measurement, making it an unlikely candidate for the major contributor to the signal. Combining the results of past studies along with recent work based on models, suggest other vessels and regions as possible sources.

  16. A Numerical Theory for Impedance Education in Three-Dimensional Normal Incidence Tubes

    NASA Technical Reports Server (NTRS)

    Watson, Willie R.; Jones, Michael G.

    2016-01-01

    A method for educing the locally-reacting acoustic impedance of a test sample mounted in a 3-D normal incidence impedance tube is presented and validated. The unique feature of the method is that the excitation frequency (or duct geometry) may be such that high-order duct modes may exist. The method educes the impedance, iteratively, by minimizing an objective function consisting of the difference between the measured and numerically computed acoustic pressure at preselected measurement points in the duct. The method is validated on planar and high-order mode sources with data synthesized from exact mode theory. These data are then subjected to random jitter to simulate the effects of measurement uncertainties on the educed impedance spectrum. The primary conclusions of the study are 1) Without random jitter the method is in excellent agreement with that for known impedance samples, and 2) Random jitter that is compatible to that found in a typical experiment has minimal impact on the accuracy of the educed impedance.

  17. Electrochemical Impedance Spectroscopy Of Metal Alloys

    NASA Technical Reports Server (NTRS)

    Macdowell, L. G.; Calle, L. M.

    1993-01-01

    Report describes use of electrochemical impedance spectroscopy (EIS) to investigate resistances of 19 alloys to corrosion under conditions similar to those of corrosive, chloride-laden seaside environment of Space Transportation System launch site. Alloys investigated: Hastelloy C-4, C-22, C-276, and B-2; Inconel(R) 600, 625, and 825; Inco(R) G-3; Monel 400; Zirconium 702; Stainless Steel 304L, 304LN, 316L, 317L, and 904L; 20Cb-3; 7Mo+N; ES2205; and Ferralium 255. Results suggest electrochemical impedance spectroscopy used to predict corrosion performances of metal alloys.

  18. Hole-Impeded-Doping-Superlattice LWIR Detectors

    NASA Technical Reports Server (NTRS)

    Maserjian, Joseph

    1991-01-01

    Hole-Impeded-Doping-Superlattice (HIDS) InAs devices proposed for use as photoconductive or photovoltaic detectors of radiation in long-wavelength infrared (LWIR) range of 8 to 17 micrometers. Array of HIDS devices fabricated on substrates GaAs or Si. Radiation incident on black surface, metal contacts for picture elements serve as reactors, effectively doubling optical path and thereby increasing absorption of photons. Photoconductive detector offers advantages of high gain and high impedance; photovoltaic detector offers lower noise and better interface to multiplexer readouts.

  19. Some Nonlinear Reconstruction Algorithms for Electrical Impedance Tomography

    SciTech Connect

    Berryman, J G

    2001-03-09

    An impedance camera [Henderson and Webster, 1978; Dines and Lytle, 1981]--or what is now more commonly called electrical impedance tomography--attempts to image the electrical impedance (or just the conductivity) distribution inside a body using electrical measurements on its boundary. The method has been used successfully in both biomedical [Brown, 1983; Barber and Brown, 1986; J. C. Newell, D. G. Gisser, and D. Isaacson, 1988; Webster, 1990] and geophysical applications [Wexler, Fry, and Neurnan, 1985; Daily, Lin, and Buscheck, 1987], but the analysis of optimal reconstruction algorithms is still progressing [Murai and Kagawa, 1985; Wexler, Fry, and Neurnan, 1985; Kohn andmore » Vogelius, 1987; Yorkey and Webster, 1987; Yorkey, Webster, and Tompkins, 1987; Berryman and Kohn, 1990; Kohn and McKenney, 1990; Santosa and Vogelius, 1990; Yorkey, 1990]. The most common application is monitoring the influx or efflux of a highly conducting fluid (such as brine in a porous rock or blood in the human body) through the volume being imaged. For biomedical applications, this met hod does not have the resolution of radiological methods, but it is comparatively safe and inexpensive and therefore provides a valuable alternative when continuous monitoring of a patient or process is desired. The following discussion is intended first t o summarize the physics of electrical impedance tomography, then to provide a few details of the data analysis and forward modeling requirements, and finally to outline some of the reconstruction algorithms that have proven to be most useful in practice. Pointers to the literature are provided throughout this brief narrative and the reader is encouraged to explore the references for more complete discussions of the various issues raised here.« less

  20. Alteration in transthoracic impedance following cardiac surgery.

    PubMed

    Khan, Nouman U; Strang, Tim; Bonsheck, Claire; Krishnamurty, Bhuvana; Hooper, Timothy L

    2008-06-01

    Haemodynamically significant ventricular tachyarrhythmias are a frequent complication in the immediate post-operative period after cardiac surgery. Successful cardioversion depends on delivery of sufficient current, which in turn is dependent on transthoracic impedance (TTI). However, it is uncertain if there is a change in TTI immediately following cardiac surgery using cardiopulmonary bypass (CPB). TTI was measured on 40 patients undergoing first time isolated cardiac surgery using CPB. TTI was recorded at 30 kHz using Bodystat Multiscan 5000 equipment before operation (with and without a positive end-expiratory pressure (PEEP) of 5 cm of H(2)O) and then at 1, 4 and 24 h after the operation. Data was analyzed to determine the relationship between pre- and post-operative variables and TTI values. Mean pre-operative TTI was 54.5+/-10.55 ohms without PEEP and 61.8+/-15.4 ohms on a PEEP of 5 cm of H(2)O. TTI dropped significantly (p<0.001) after the operation to 47.2+/-10.6 ohms at 1 h, 42.6+/-10.2 ohms at 4 h and 41.8+/-10.4 ohms at 24 h. A positive correlation was noted between duration of operation and TTI change at 1 h (r=0.38; p=0.016). There was no significant correlation between the duration of bypass and change in TTI. TTI decreases by more than 30% in the immediate post-operative period following cardiac surgery. This state may favour defibrillation at lower energy levels.