Robust Alternatives to the Standard Deviation in Processing of Physics Experimental Data
NASA Astrophysics Data System (ADS)
Shulenin, V. P.
2016-10-01
Properties of robust estimations of the scale parameter are studied. It is noted that the median of absolute deviations and the modified estimation of the average Gini differences have asymptotically normal distributions and bounded influence functions, are B-robust estimations, and hence, unlike the estimation of the standard deviation, are protected from the presence of outliers in the sample. Results of comparison of estimations of the scale parameter are given for a Gaussian model with contamination. An adaptive variant of the modified estimation of the average Gini differences is considered.
9 CFR 439.10 - Criteria for obtaining accreditation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...
9 CFR 439.10 - Criteria for obtaining accreditation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...
9 CFR 439.10 - Criteria for obtaining accreditation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...
9 CFR 439.10 - Criteria for obtaining accreditation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...
9 CFR 439.10 - Criteria for obtaining accreditation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... absolute value of the average standardized difference must not exceed the following: (i) For food chemistry... samples must be less than 5.0. A result will have a large deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is less than 2.5 and otherwise a measure equal...
A Case Study to Improve Emergency Room Patient Flow at Womack Army Medical Center
2009-06-01
use just the previous month, moving average 2-month period ( MA2 ) uses the average from the previous two months, moving average 3-month period (MA3...ED prior to discharge by provider) MA2 /MA3/MA4 - moving averages of 2-4 months in length MAD - mean absolute deviation (measure of accuracy for
Density of Jatropha curcas Seed Oil and its Methyl Esters: Measurement and Estimations
NASA Astrophysics Data System (ADS)
Veny, Harumi; Baroutian, Saeid; Aroua, Mohamed Kheireddine; Hasan, Masitah; Raman, Abdul Aziz; Sulaiman, Nik Meriam Nik
2009-04-01
Density data as a function of temperature have been measured for Jatropha curcas seed oil, as well as biodiesel jatropha methyl esters at temperatures from above their melting points to 90 ° C. The data obtained were used to validate the method proposed by Spencer and Danner using a modified Rackett equation. The experimental and estimated density values using the modified Rackett equation gave almost identical values with average absolute percent deviations less than 0.03% for the jatropha oil and 0.04% for the jatropha methyl esters. The Janarthanan empirical equation was also employed to predict jatropha biodiesel densities. This equation performed equally well with average absolute percent deviations within 0.05%. Two simple linear equations for densities of jatropha oil and its methyl esters are also proposed in this study.
A Robust Interpretation of Teaching Evaluation Ratings
ERIC Educational Resources Information Center
Bi, Henry H.
2018-01-01
There are no absolute standards regarding what teaching evaluation ratings are satisfactory. It is also problematic to compare teaching evaluation ratings with the average or with a cutoff number to determine whether they are adequate. In this paper, we use average and standard deviation charts (X[overbar]-S charts), which are based on the theory…
Discrete distributed strain sensing of intelligent structures
NASA Technical Reports Server (NTRS)
Anderson, Mark S.; Crawley, Edward F.
1992-01-01
Techniques are developed for the design of discrete highly distributed sensor systems for use in intelligent structures. First the functional requirements for such a system are presented. Discrete spatially averaging strain sensors are then identified as satisfying the functional requirements. A variety of spatial weightings for spatially averaging sensors are examined, and their wave number characteristics are determined. Preferable spatial weightings are identified. Several numerical integration rules used to integrate such sensors in order to determine the global deflection of the structure are discussed. A numerical simulation is conducted using point and rectangular sensors mounted on a cantilevered beam under static loading. Gage factor and sensor position uncertainties are incorporated to assess the absolute error and standard deviation of the error in the estimated tip displacement found by numerically integrating the sensor outputs. An experiment is carried out using a statically loaded cantilevered beam with five point sensors. It is found that in most cases the actual experimental error is within one standard deviation of the absolute error as found in the numerical simulation.
Foster, Ken; Anwar, Nasim; Pogue, Rhea; Morré, Dorothy M.; Keenan, T. W.; Morré, D. James
2003-01-01
Seasonal decomposition analyses were applied to the statistical evaluation of an oscillating activity for a plasma membrane NADH oxidase activity with a temperature compensated period of 24 min. The decomposition fits were used to validate the cyclic oscillatory pattern. Three measured values, average percentage error (MAPE), a measure of the periodic oscillation, mean average deviation (MAD), a measure of the absolute average deviations from the fitted values, and mean standard deviation (MSD), the measure of standard deviation from the fitted values plus R-squared and the Henriksson-Merton p value were used to evaluate accuracy. Decomposition was carried out by fitting a trend line to the data, then detrending the data if necessary, by subtracting the trend component. The data, with or without detrending, were then smoothed by subtracting a centered moving average of length equal to the period length determined by Fourier analysis. Finally, the time series were decomposed into cyclic and error components. The findings not only validate the periodic nature of the major oscillations but suggest, as well, that the minor intervening fluctuations also recur within each period with a reproducible pattern of recurrence. PMID:19330112
Introducing the Mean Absolute Deviation "Effect" Size
ERIC Educational Resources Information Center
Gorard, Stephen
2015-01-01
This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…
NASA Technical Reports Server (NTRS)
Goldhirsh, J.
1982-01-01
The first absolute rain fade distribution method described establishes absolute fade statistics at a given site by means of a sampled radar data base. The second method extrapolates absolute fade statistics from one location to another, given simultaneously measured fade and rain rate statistics at the former. Both methods employ similar conditional fade statistic concepts and long term rain rate distributions. Probability deviations in the 2-19% range, with an 11% average, were obtained upon comparison of measured and predicted levels at given attenuations. The extrapolation of fade distributions to other locations at 28 GHz showed very good agreement with measured data at three sites located in the continental temperate region.
A standardized model for predicting flap failure using indocyanine green dye
NASA Astrophysics Data System (ADS)
Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.
2016-03-01
Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.
Estimation of the lower flammability limit of organic compounds as a function of temperature.
Rowley, J R; Rowley, R L; Wilding, W V
2011-02-15
A new method of estimating the lower flammability limit (LFL) of general organic compounds is presented. The LFL is predicted at 298 K for gases and the lower temperature limit for solids and liquids from structural contributions and the ideal gas heat of formation of the fuel. The average absolute deviation from more than 500 experimental data points is 10.7%. In a previous study, the widely used modified Burgess-Wheeler law was shown to underestimate the effect of temperature on the lower flammability limit when determined in a large-diameter vessel. An improved version of the modified Burgess-Wheeler law is presented that represents the temperature dependence of LFL data determined in large-diameter vessels more accurately. When the LFL is estimated at increased temperatures using a combination of this model and the proposed structural-contribution method, an average absolute deviation of 3.3% is returned when compared with 65 data points for 17 organic compounds determined in an ASHRAE-style apparatus. Copyright © 2010 Elsevier B.V. All rights reserved.
A FORMULA FOR HUMAN PAROTID FLUID COLLECTED WITHOUT EXOGENEOUS STIMULATION.
Parotid fluid was collected from 4,589 systemically healthy males between 17 and 22 years of age. Collection devices were placed with an absolute...secretion of the parotid gland. For all 4,589 subjects from the 8 experiments the mean rate of flow was 0.040 ml./minute with an average standard deviation of
Modelling PET radionuclide production in tissue and external targets using Geant4
NASA Astrophysics Data System (ADS)
Amin, T.; Infantino, A.; Lindsay, C.; Barlow, R.; Hoehr, C.
2017-07-01
The Proton Therapy Facility in TRIUMF provides 74 MeV protons extracted from a 500 MeV H- cyclotron for ocular melanoma treatments. During treatment, positron emitting radionuclides such as 1C, 15O and 13N are produced in patient tissue. Using PET scanners, the isotopic activity distribution can be measured for in-vivo range verification. A second cyclotron, the TR13, provides 13 MeV protons onto liquid targets for the production of PET radionuclides such as 18F, 13N or 68Ga, for medical applications. The aim of this work was to validate Geant4 against FLUKA and experimental measurements for production of the above-mentioned isotopes using the two cyclotrons. The results show variable degrees of agreement. For proton therapy, the proton-range agreement was within 2 mm for 11C activity, whereas 13N disagreed. For liquid targets at the TR13 the average absolute deviation ratio between FLUKA and experiment was 1.9±2.7, whereas the average absolute deviation ratio between Geant4 and experiment was 0. 6±0.4. This is due to the uncertainties present in experimentally determined reaction cross sections.
NASA Astrophysics Data System (ADS)
Wu, Xiaoru; Gao, Yingyu; Ban, Chunlan; Huang, Qiang
2016-09-01
In this paper the results of the vapor-liquid equilibria study at 100 kPa are presented for two binary systems: α-phenylethylamine(1) + toluene (2) and (α-phenylethylamine(1) + cyclohexane(2)). The binary VLE data of the two systems were correlated by the Wilson, NRTL, and UNIQUAC models. For each binary system the deviations between the results of the correlations and the experimental data have been calculated. For the both binary systems the average relative deviations in temperature for the three models were lower than 0.99%. The average absolute deviations in vapour phase composition (mole fractions) and in temperature T were lower than 0.0271 and 1.93 K, respectively. Thermodynamic consistency has been tested for all vapor-liquid equilibrium data by the Herrington method. The values calculated by Wilson and NRTL equations satisfied the thermodynamics consistency test for the both two systems, while the values calculated by UNIQUAC equation didn't.
Dust-Corrected Star Formation Rates in Galaxies with Outer Rings
NASA Astrophysics Data System (ADS)
Kostiuk, I.; Silchenko, O.
2018-03-01
The star formation rates SFR, as well as the SFR surface densities ΣSFR and absolute stellar magnitudes MAB, are determined and corrected for interinsic dust absorption for 34 disk galaxies of early morphological types with an outer ring structure and ultraviolet emission from the ring. These characteristic are determined for the outer ring structures and for the galaxies as a whole. Data from the space telescopes GALEX (in the NUV and FUV ultraviolet ranges) and WISE (in the W4 22 μm infrared band) are used. The average relative deviation in the corrected SFR and ΣSFR derived from the NUV and FUV bands is only 19.0%, so their averaged values are used for statistical consideration. The relations between the dust-corrected SFR characteristics, UV colours, the galaxy morphological type, absolute magnitude are illustrated.
NASA Astrophysics Data System (ADS)
Braun, Jaroslav; Štroner, Martin; Urban, Rudolf
2015-05-01
All surveying instruments and their measurements suffer from some errors. To refine the measurement results, it is necessary to use procedures restricting influence of the instrument errors on the measured values or to implement numerical corrections. In precise engineering surveying industrial applications the accuracy of the distances usually realized on relatively short distance is a key parameter limiting the resulting accuracy of the determined values (coordinates, etc.). To determine the size of systematic and random errors of the measured distances were made test with the idea of the suppression of the random error by the averaging of the repeating measurement, and reducing systematic errors influence of by identifying their absolute size on the absolute baseline realized in geodetic laboratory at the Faculty of Civil Engineering CTU in Prague. The 16 concrete pillars with forced centerings were set up and the absolute distances between the points were determined with a standard deviation of 0.02 millimetre using a Leica Absolute Tracker AT401. For any distance measured by the calibrated instruments (up to the length of the testing baseline, i.e. 38.6 m) can now be determined the size of error correction of the distance meter in two ways: Firstly by the interpolation on the raw data, or secondly using correction function derived by previous FFT transformation usage. The quality of this calibration and correction procedure was tested on three instruments (Trimble S6 HP, Topcon GPT-7501, Trimble M3) experimentally using Leica Absolute Tracker AT401. By the correction procedure was the standard deviation of the measured distances reduced significantly to less than 0.6 mm. In case of Topcon GPT-7501 is the nominal standard deviation 2 mm, achieved (without corrections) 2.8 mm and after corrections 0.55 mm; in case of Trimble M3 is nominal standard deviation 3 mm, achieved (without corrections) 1.1 mm and after corrections 0.58 mm; and finally in case of Trimble S6 is nominal standard deviation 1 mm, achieved (without corrections) 1.2 mm and after corrections 0.51 mm. Proposed procedure of the calibration and correction is in our opinion very suitable for increasing of the accuracy of the electronic distance measurement and allows the use of the common surveying instrument to achieve uncommonly high precision.
Echenique-Robba, Pablo; Nelo-Bazán, María Alejandra; Carrodeguas, José A
2013-01-01
When the value of a quantity x for a number of systems (cells, molecules, people, chunks of metal, DNA vectors, so on) is measured and the aim is to replicate the whole set again for different trials or assays, despite the efforts for a near-equal design, scientists might often obtain quite different measurements. As a consequence, some systems' averages present standard deviations that are too large to render statistically significant results. This work presents a novel correction method of a very low mathematical and numerical complexity that can reduce the standard deviation of such results and increase their statistical significance. Two conditions are to be met: the inter-system variations of x matter while its absolute value does not, and a similar tendency in the values of x must be present in the different assays (or in other words, the results corresponding to different assays must present a high linear correlation). We demonstrate the improvements this method offers with a cell biology experiment, but it can definitely be applied to any problem that conforms to the described structure and requirements and in any quantitative scientific field that deals with data subject to uncertainty.
A determination of the absolute radiant energy of a Robertson-Berger meter sunburn unit
NASA Astrophysics Data System (ADS)
DeLuisi, John J.; Harris, Joyce M.
Data from a Robertson-Berger (RB) sunburn meter were compared with concurrent measurements obtained with an ultraviolet double monochromator (DM), and the absolute energy of one sunburn unit measured by the RB-meter was determined. It was found that at a solar zenith angle of 30° one sunburn unit (SU) is equivalent to 35 ± 4 mJ cm -2, and at a solar zenith angle of 69°, one SU is equivalent to 20 ± 2 mJ cm -2 (relative to a wavelength of 297 nm), where the rate of change is non-linear. The deviation is due to the different response functions of the RB-meter and the DM system used to simulate the response of human skin to the incident u.v. solar spectrum. The average growth rate of the deviation with increasing solar zenith angle was found to be 1.2% per degree between solar zenith angles 30 and 50° and 2.3% per degree between solar zenith angles 50 and 70°. The deviations of response with solar zenith angle were found to be consistent with reported RB-meter characteristics.
The Effectiveness of a Rater Training Booklet in Increasing Accuracy of Performance Ratings
1988-04-01
subjects’ ratings were compared for accuracy. The dependent measure was the absolute deviation score of each individual’s rating from the "true score". The...subjects’ ratings were compared for accuracy. The dependent measure was the absolute deviation score of each individual’s rating from the "true score". The...r IS % _. Findings: The absolute deviation scores of each individual’s ratings from the "true score" provided by subject matter experts were analyzed
Darajeh, Negisa; Idris, Azni; Fard Masoumi, Hamid Reza; Nourani, Abolfazl; Truong, Paul; Rezania, Shahabaldin
2017-05-04
Artificial neural networks (ANNs) have been widely used to solve the problems because of their reliable, robust, and salient characteristics in capturing the nonlinear relationships between variables in complex systems. In this study, ANN was applied for modeling of Chemical Oxygen Demand (COD) and biodegradable organic matter (BOD) removal from palm oil mill secondary effluent (POMSE) by vetiver system. The independent variable, including POMSE concentration, vetiver slips density, and removal time, has been considered as input parameters to optimize the network, while the removal percentage of COD and BOD were selected as output. To determine the number of hidden layer nodes, the root mean squared error of testing set was minimized, and the topologies of the algorithms were compared by coefficient of determination and absolute average deviation. The comparison indicated that the quick propagation (QP) algorithm had minimum root mean squared error and absolute average deviation, and maximum coefficient of determination. The importance values of the variables was included vetiver slips density with 42.41%, time with 29.8%, and the POMSE concentration with 27.79%, which showed none of them, is negligible. Results show that the ANN has great potential ability in prediction of COD and BOD removal from POMSE with residual standard error (RSE) of less than 0.45%.
Forecasting of Water Consumptions Expenditure Using Holt-Winter’s and ARIMA
NASA Astrophysics Data System (ADS)
Razali, S. N. A. M.; Rusiman, M. S.; Zawawi, N. I.; Arbin, N.
2018-04-01
This study is carried out to forecast water consumption expenditure of Malaysian university specifically at University Tun Hussein Onn Malaysia (UTHM). The proposed Holt-Winter’s and Auto-Regressive Integrated Moving Average (ARIMA) models were applied to forecast the water consumption expenditure in Ringgit Malaysia from year 2006 until year 2014. The two models were compared and performance measurement of the Mean Absolute Percentage Error (MAPE) and Mean Absolute Deviation (MAD) were used. It is found that ARIMA model showed better results regarding the accuracy of forecast with lower values of MAPE and MAD. Analysis showed that ARIMA (2,1,4) model provided a reasonable forecasting tool for university campus water usage.
NASA Astrophysics Data System (ADS)
Dong, Min; Dong, Chenghui; Guo, Miao; Wang, Zhe; Mu, Xiaomin
2018-04-01
Multiresolution-based methods, such as wavelet and Contourlet are usually used to image fusion. This work presents a new image fusion frame-work by utilizing area-based standard deviation in dual tree Contourlet trans-form domain. Firstly, the pre-registered source images are decomposed with dual tree Contourlet transform; low-pass and high-pass coefficients are obtained. Then, the low-pass bands are fused with weighted average based on area standard deviation rather than the simple "averaging" rule. While the high-pass bands are merged with the "max-absolute' fusion rule. Finally, the modified low-pass and high-pass coefficients are used to reconstruct the final fused image. The major advantage of the proposed fusion method over conventional fusion is the approximately shift invariance and multidirectional selectivity of dual tree Contourlet transform. The proposed method is compared with wavelet- , Contourletbased methods and other the state-of-the art methods on common used multi focus images. Experiments demonstrate that the proposed fusion framework is feasible and effective, and it performs better in both subjective and objective evaluation.
Note: An absolute X-Y-Θ position sensor using a two-dimensional phase-encoded binary scale
NASA Astrophysics Data System (ADS)
Kim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan
2018-04-01
This Note presents a new absolute X-Y-Θ position sensor for measuring planar motion of a precision multi-axis stage system. By analyzing the rotated image of a two-dimensional phase-encoded binary scale (2D), the absolute 2D position values at two separated points were obtained and the absolute X-Y-Θ position could be calculated combining these values. The sensor head was constructed using a board-level camera, a light-emitting diode light source, an imaging lens, and a cube beam-splitter. To obtain the uniform intensity profiles from the vignette scale image, we selected the averaging directions deliberately, and higher resolution in the angle measurement could be achieved by increasing the allowable offset size. The performance of a prototype sensor was evaluated in respect of resolution, nonlinearity, and repeatability. The sensor could resolve 25 nm linear and 0.001° angular displacements clearly, and the standard deviations were less than 18 nm when 2D grid positions were measured repeatedly.
NASA Astrophysics Data System (ADS)
Li, Qimeng; Li, Shichun; Hu, Xianglong; Zhao, Jing; Xin, Wenhui; Song, Yuehui; Hua, Dengxin
2018-01-01
The absolute measurement technique for atmospheric temperature can avoid the calibration process and improve the measurement accuracy. To achieve the rotational Raman temperature lidar of absolute measurement, the two-stage parallel multi-channel spectroscopic filter combined a first-order blazed grating with a fiber Bragg grating is designed and its performance is tested. The parameters and the optical path structure of the core cascaded-device (micron-level fiber array) are optimized, the optical path of the primary spectroscope is simulated and the maximum centrifugal distortion of the rotational Raman spectrum is approximately 0.0031 nm, the centrifugal ratio of 0.69%. The experimental results show that the channel coefficients of the primary spectroscope are 0.67, 0.91, 0.67, 0.75, 0.82, 0.63, 0.87, 0.97, 0.89, 0.87 and 1 by using the twelfth channel as a reference and the average FWHM is about 0.44 nm. The maximum deviation between the experimental wavelength and the theoretical value is approximately 0.0398 nm, with the deviation degree of 8.86%. The effective suppression to elastic scattering signal are 30.6, 35.2, 37.1, 38.4, 36.8, 38.2, 41.0, 44.3, 44.0, 46.7 dB. That means, combined with the second spectroscope, the suppression at least is up to 65 dB. Therefore we can fine extract single rotational Raman line to achieve the absolute measurement technique.
Zhang, You; Yin, Fang-Fang; Ren, Lei
2015-08-01
Lung cancer treatment is susceptible to treatment errors caused by interfractional anatomical and respirational variations of the patient. On-board treatment dose verification is especially critical for the lung stereotactic body radiation therapy due to its high fractional dose. This study investigates the feasibility of using cone-beam (CB)CT images estimated by a motion modeling and free-form deformation (MM-FD) technique for on-board dose verification. Both digital and physical phantom studies were performed. Various interfractional variations featuring patient motion pattern change, tumor size change, and tumor average position change were simulated from planning CT to on-board images. The doses calculated on the planning CT (planned doses), the on-board CBCT estimated by MM-FD (MM-FD doses), and the on-board CBCT reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm (FDK doses) were compared to the on-board dose calculated on the "gold-standard" on-board images (gold-standard doses). The absolute deviations of minimum dose (ΔDmin), maximum dose (ΔDmax), and mean dose (ΔDmean), and the absolute deviations of prescription dose coverage (ΔV100%) were evaluated for the planning target volume (PTV). In addition, 4D on-board treatment dose accumulations were performed using 4D-CBCT images estimated by MM-FD in the physical phantom study. The accumulated doses were compared to those measured using optically stimulated luminescence (OSL) detectors and radiochromic films. Compared with the planned doses and the FDK doses, the MM-FD doses matched much better with the gold-standard doses. For the digital phantom study, the average (± standard deviation) ΔDmin, ΔDmax, ΔDmean, and ΔV100% (values normalized by the prescription dose or the total PTV) between the planned and the gold-standard PTV doses were 32.9% (±28.6%), 3.0% (±2.9%), 3.8% (±4.0%), and 15.4% (±12.4%), respectively. The corresponding values of FDK PTV doses were 1.6% (±1.9%), 1.2% (±0.6%), 2.2% (±0.8%), and 17.4% (±15.3%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.3% (±0.2%), 0.9% (±0.6%), 0.6% (±0.4%), and 1.0% (±0.8%), respectively. Similarly, for the physical phantom study, the average ΔDmin, ΔDmax, ΔDmean, and ΔV100% of planned PTV doses were 38.1% (±30.8%), 3.5% (±5.1%), 3.0% (±2.6%), and 8.8% (±8.0%), respectively. The corresponding values of FDK PTV doses were 5.8% (±4.5%), 1.6% (±1.6%), 2.0% (±0.9%), and 9.3% (±10.5%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.4% (±0.8%), 0.8% (±1.0%), 0.5% (±0.4%), and 0.8% (±0.8%), respectively. For the 4D dose accumulation study, the average (± standard deviation) absolute dose deviation (normalized by local doses) between the accumulated doses and the OSL measured doses was 3.3% (±2.7%). The average gamma index (3%/3 mm) between the accumulated doses and the radiochromic film measured doses was 94.5% (±2.5%). MM-FD estimated 4D-CBCT enables accurate on-board dose calculation and accumulation for lung radiation therapy. It can potentially be valuable for treatment quality assessment and adaptive radiation therapy.
Neural network versus classical time series forecasting models
NASA Astrophysics Data System (ADS)
Nor, Maria Elena; Safuan, Hamizah Mohd; Shab, Noorzehan Fazahiyah Md; Asrul, Mohd; Abdullah, Affendi; Mohamad, Nurul Asmaa Izzati; Lee, Muhammad Hisyam
2017-05-01
Artificial neural network (ANN) has advantage in time series forecasting as it has potential to solve complex forecasting problems. This is because ANN is data driven approach which able to be trained to map past values of a time series. In this study the forecast performance between neural network and classical time series forecasting method namely seasonal autoregressive integrated moving average models was being compared by utilizing gold price data. Moreover, the effect of different data preprocessing on the forecast performance of neural network being examined. The forecast accuracy was evaluated using mean absolute deviation, root mean square error and mean absolute percentage error. It was found that ANN produced the most accurate forecast when Box-Cox transformation was used as data preprocessing.
Forecasting Error Calculation with Mean Absolute Deviation and Mean Absolute Percentage Error
NASA Astrophysics Data System (ADS)
Khair, Ummul; Fahmi, Hasanul; Hakim, Sarudin Al; Rahim, Robbi
2017-12-01
Prediction using a forecasting method is one of the most important things for an organization, the selection of appropriate forecasting methods is also important but the percentage error of a method is more important in order for decision makers to adopt the right culture, the use of the Mean Absolute Deviation and Mean Absolute Percentage Error to calculate the percentage of mistakes in the least square method resulted in a percentage of 9.77% and it was decided that the least square method be worked for time series and trend data.
Vapor-liquid equilibria for an R134a/lubricant mixture: Measurements and equation-of-state modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huber, M.L.; Holcomb, C.D.; Outcalt, S.L.
2000-07-01
The authors measured bubble point pressures and coexisting liquid densities for two mixtures of R-134a and a polyolester (POE) lubricant. The mass fraction of the lubricant was approximately 9% and 12%, and the temperature ranged from 280 K to 355 K. The authors used the Elliott, Suresh, and Donohue (ESD) equation of state to model the bubble point pressure data. The bubble point pressures were represented with an average absolute deviation of 2.5%. A binary interaction parameter reduced the deviation to 1.4%. The authors also applied the ESD model to other R-134a/POE lubricant data in the literature. As the concentrationmore » of the lubricant increased, the performance of the model deteriorated markedly. However, the use of a single binary interaction parameter reduced the deviations significantly.« less
Concistrè, A; Grillo, A; La Torre, G; Carretta, R; Fabris, B; Petramala, L; Marinelli, C; Rebellato, A; Fallo, F; Letizia, C
2018-04-01
Primary hyperparathyroidism is associated with a cluster of cardiovascular manifestations, including hypertension, leading to increased cardiovascular risk. The aim of our study was to investigate the ambulatory blood pressure monitoring-derived short-term blood pressure variability in patients with primary hyperparathyroidism, in comparison with patients with essential hypertension and normotensive controls. Twenty-five patients with primary hyperparathyroidism (7 normotensive,18 hypertensive) underwent ambulatory blood pressure monitoring at diagnosis, and fifteen out of them were re-evaluated after parathyroidectomy. Short-term-blood pressure variability was derived from ambulatory blood pressure monitoring and calculated as the following: 1) Standard Deviation of 24-h, day-time and night-time-BP; 2) the average of day-time and night-time-Standard Deviation, weighted for the duration of the day and night periods (24-h "weighted" Standard Deviation of BP); 3) average real variability, i.e., the average of the absolute differences between all consecutive BP measurements. Baseline data of normotensive and essential hypertension patients were matched for age, sex, BMI and 24-h ambulatory blood pressure monitoring values with normotensive and hypertensive-primary hyperparathyroidism patients, respectively. Normotensive-primary hyperparathyroidism patients showed a 24-h weighted Standard Deviation (P < 0.01) and average real variability (P < 0.05) of systolic blood pressure higher than that of 12 normotensive controls. 24-h average real variability of systolic BP, as well as serum calcium and parathyroid hormone levels, were reduced in operated patients (P < 0.001). A positive correlation of serum calcium and parathyroid hormone with 24-h-average real variability of systolic BP was observed in the entire primary hyperparathyroidism patients group (P = 0.04, P = 0.02; respectively). Systolic blood pressure variability is increased in normotensive patients with primary hyperparathyroidism and is reduced by parathyroidectomy, and may potentially represent an additional cardiovascular risk factor in this disease.
Intensity stabilisation of optical pulse sequences for coherent control of laser-driven qubits
NASA Astrophysics Data System (ADS)
Thom, Joseph; Yuen, Ben; Wilpers, Guido; Riis, Erling; Sinclair, Alastair G.
2018-05-01
We demonstrate a system for intensity stabilisation of optical pulse sequences used in laser-driven quantum control of trapped ions. Intensity instability is minimised by active stabilisation of the power (over a dynamic range of > 104) and position of the focused beam at the ion. The fractional Allan deviations in power were found to be <2.2 × 10^{-4} for averaging times from 1 to 16,384 s. Over similar times, the absolute Allan deviation of the beam position is <0.1 μm for a 45 {μ }m beam diameter. Using these residual power and position instabilities, we estimate the associated contributions to infidelity in example qubit logic gates to be below 10^{-6} per gate.
Thermal sensing of cryogenic wind tunnel model surfaces Evaluation of silicon diodes
NASA Technical Reports Server (NTRS)
Daryabeigi, K.; Ash, R. L.; Dillon-Townes, L. A.
1986-01-01
Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.
Thermal sensing of cryogenic wind tunnel model surfaces - Evaluation of silicon diodes
NASA Technical Reports Server (NTRS)
Daryabeigi, Kamran; Ash, Robert L.; Dillon-Townes, Lawrence A.
1986-01-01
Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.
Sex Ratios at Birth and Environmental Temperatures
NASA Astrophysics Data System (ADS)
Lerchl, Alexander
The relationship between average monthly air temperature and sex ratios at birth (SRB) was analyzed for children born in Germany during the period 1946-1995. Both the absolute temperature and - more markedly - the monthly temperature deviations from the overall mean were significantly positively correlated with the SRB (P<0.01) when temperatures were time-lagged against the SRB data by -10 or -11months. It is concluded that the sex of the offspring is partially determined by environmental temperatures prior to conception.
Single-breath diffusing capacity for carbon monoxide instrument accuracy across 3 health systems.
Hegewald, Matthew J; Markewitz, Boaz A; Wilson, Emily L; Gallo, Heather M; Jensen, Robert L
2015-03-01
Measuring diffusing capacity of the lung for carbon monoxide (DLCO) is complex and associated with wide intra- and inter-laboratory variability. Increased D(LCO) variability may have important clinical consequences. The objective of the study was to assess instrument performance across hospital pulmonary function testing laboratories using a D(LCO) simulator that produces precise and repeatable D(LCO) values. D(LCO) instruments were tested with CO gas concentrations representing medium and high range D(LCO) values. The absolute difference between observed and target D(LCO) value was used to determine measurement accuracy; accuracy was defined as an average deviation from the target value of < 2.0 mL/min/mm Hg. Accuracy of inspired volume measurement and gas sensors were also determined. Twenty-three instruments were tested across 3 healthcare systems. The mean absolute deviation from the target value was 1.80 mL/min/mm Hg (range 0.24-4.23) with 10 of 23 instruments (43%) being inaccurate. High volume laboratories performed better than low volume laboratories, although the difference was not significant. There was no significant difference among the instruments by manufacturers. Inspired volume was not accurate in 48% of devices; mean absolute deviation from target value was 3.7%. Instrument gas analyzers performed adequately in all instruments. D(LCO) instrument accuracy was unacceptable in 43% of devices. Instrument inaccuracy can be primarily attributed to errors in inspired volume measurement and not gas analyzer performance. D(LCO) instrument performance may be improved by regular testing with a simulator. Caution should be used when comparing D(LCO) results reported from different laboratories. Copyright © 2015 by Daedalus Enterprises.
Xu, Zhoubing; Gertz, Adam L.; Burke, Ryan P.; Bansal, Neil; Kang, Hakmook; Landman, Bennett A.; Abramson, Richard G.
2016-01-01
OBJECTIVES Multi-atlas fusion is a promising approach for computer-assisted segmentation of anatomical structures. The purpose of this study was to evaluate the accuracy and time efficiency of multi-atlas segmentation for estimating spleen volumes on clinically-acquired CT scans. MATERIALS AND METHODS Under IRB approval, we obtained 294 deidentified (HIPAA-compliant) abdominal CT scans on 78 subjects from a recent clinical trial. We compared five pipelines for obtaining splenic volumes: Pipeline 1–manual segmentation of all scans, Pipeline 2–automated segmentation of all scans, Pipeline 3–automated segmentation of all scans with manual segmentation for outliers on a rudimentary visual quality check, Pipelines 4 and 5–volumes derived from a unidimensional measurement of craniocaudal spleen length and three-dimensional splenic index measurements, respectively. Using Pipeline 1 results as ground truth, the accuracy of Pipelines 2–5 (Dice similarity coefficient [DSC], Pearson correlation, R-squared, and percent and absolute deviation of volume from ground truth) were compared for point estimates of splenic volume and for change in splenic volume over time. Time cost was also compared for Pipelines 1–5. RESULTS Pipeline 3 was dominant in terms of both accuracy and time cost. With a Pearson correlation coefficient of 0.99, average absolute volume deviation 23.7 cm3, and 1 minute per scan, Pipeline 3 yielded the best results. The second-best approach was Pipeline 5, with a Pearson correlation coefficient 0.98, absolute deviation 46.92 cm3, and 1 minute 30 seconds per scan. Manual segmentation (Pipeline 1) required 11 minutes per scan. CONCLUSION A computer-automated segmentation approach with manual correction of outliers generated accurate splenic volumes with reasonable time efficiency. PMID:27519156
Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar
Gabella, Marco; Leuenberger, Andreas
2017-01-01
The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of −0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the “small” (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB. PMID:28531164
Dual-Polarization Observations of Slowly Varying Solar Emissions from a Mobile X-Band Radar.
Gabella, Marco; Leuenberger, Andreas
2017-05-22
The radio noise that comes from the Sun has been reported in literature as a reference signal to check the quality of dual-polarization weather radar receivers for the S-band and C-band. In most cases, the focus was on relative calibration: horizontal and vertical polarizations were evaluated versus the reference signal mainly in terms of standard deviation of the difference. This means that the investigated radar receivers were able to reproduce the slowly varying component of the microwave signal emitted by the Sun. A novel method, aimed at the absolute calibration of dual-polarization receivers, has recently been presented and applied for the C-band. This method requires the antenna beam axis to be pointed towards the center of the Sun for less than a minute. Standard deviations of the difference as low as 0.1 dB have been found for the Swiss radars. As far as the absolute calibration is concerned, the average differences were of the order of -0.6 dB (after noise subtraction). The method has been implemented on a mobile, X-band radar, and this paper presents the successful results that were obtained during the 2016 field campaign in Payerne (Switzerland). Despite a relatively poor Sun-to-Noise ratio, the "small" (~0.4 dB) amplitude of the slowly varying emission was captured and reproduced; the standard deviation of the difference between the radar and the reference was ~0.2 dB. The absolute calibration of the vertical and horizontal receivers was satisfactory. After the noise subtraction and atmospheric correction a, the mean difference was close to 0 dB.
Water quality management using statistical analysis and time-series prediction model
NASA Astrophysics Data System (ADS)
Parmar, Kulwinder Singh; Bhardwaj, Rashmi
2014-12-01
This paper deals with water quality management using statistical analysis and time-series prediction model. The monthly variation of water quality standards has been used to compare statistical mean, median, mode, standard deviation, kurtosis, skewness, coefficient of variation at Yamuna River. Model validated using R-squared, root mean square error, mean absolute percentage error, maximum absolute percentage error, mean absolute error, maximum absolute error, normalized Bayesian information criterion, Ljung-Box analysis, predicted value and confidence limits. Using auto regressive integrated moving average model, future water quality parameters values have been estimated. It is observed that predictive model is useful at 95 % confidence limits and curve is platykurtic for potential of hydrogen (pH), free ammonia, total Kjeldahl nitrogen, dissolved oxygen, water temperature (WT); leptokurtic for chemical oxygen demand, biochemical oxygen demand. Also, it is observed that predicted series is close to the original series which provides a perfect fit. All parameters except pH and WT cross the prescribed limits of the World Health Organization /United States Environmental Protection Agency, and thus water is not fit for drinking, agriculture and industrial use.
2014-01-01
Background It is important to predict the quality of a protein structural model before its native structure is known. The method that can predict the absolute local quality of individual residues in a single protein model is rare, yet particularly needed for using, ranking and refining protein models. Results We developed a machine learning tool (SMOQ) that can predict the distance deviation of each residue in a single protein model. SMOQ uses support vector machines (SVM) with protein sequence and structural features (i.e. basic feature set), including amino acid sequence, secondary structures, solvent accessibilities, and residue-residue contacts to make predictions. We also trained a SVM model with two new additional features (profiles and SOV scores) on 20 CASP8 targets and found that including them can only improve the performance when real deviations between native and model are higher than 5Å. The SMOQ tool finally released uses the basic feature set trained on 85 CASP8 targets. Moreover, SMOQ implemented a way to convert predicted local quality scores into a global quality score. SMOQ was tested on the 84 CASP9 single-domain targets. The average difference between the residue-specific distance deviation predicted by our method and the actual distance deviation on the test data is 2.637Å. The global quality prediction accuracy of the tool is comparable to other good tools on the same benchmark. Conclusion SMOQ is a useful tool for protein single model quality assessment. Its source code and executable are available at: http://sysbio.rnet.missouri.edu/multicom_toolbox/. PMID:24776231
Cao, Renzhi; Wang, Zheng; Wang, Yiheng; Cheng, Jianlin
2014-04-28
It is important to predict the quality of a protein structural model before its native structure is known. The method that can predict the absolute local quality of individual residues in a single protein model is rare, yet particularly needed for using, ranking and refining protein models. We developed a machine learning tool (SMOQ) that can predict the distance deviation of each residue in a single protein model. SMOQ uses support vector machines (SVM) with protein sequence and structural features (i.e. basic feature set), including amino acid sequence, secondary structures, solvent accessibilities, and residue-residue contacts to make predictions. We also trained a SVM model with two new additional features (profiles and SOV scores) on 20 CASP8 targets and found that including them can only improve the performance when real deviations between native and model are higher than 5Å. The SMOQ tool finally released uses the basic feature set trained on 85 CASP8 targets. Moreover, SMOQ implemented a way to convert predicted local quality scores into a global quality score. SMOQ was tested on the 84 CASP9 single-domain targets. The average difference between the residue-specific distance deviation predicted by our method and the actual distance deviation on the test data is 2.637Å. The global quality prediction accuracy of the tool is comparable to other good tools on the same benchmark. SMOQ is a useful tool for protein single model quality assessment. Its source code and executable are available at: http://sysbio.rnet.missouri.edu/multicom_toolbox/.
Nilsonne, A; Sundberg, J; Ternström, S; Askenfelt, A
1988-02-01
A method of measuring the rate of change of fundamental frequency has been developed in an effort to find acoustic voice parameters that could be useful in psychiatric research. A minicomputer program was used to extract seven parameters from the fundamental frequency contour of tape-recorded speech samples: (1) the average rate of change of the fundamental frequency and (2) its standard deviation, (3) the absolute rate of fundamental frequency change, (4) the total reading time, (5) the percent pause time of the total reading time, (6) the mean, and (7) the standard deviation of the fundamental frequency distribution. The method is demonstrated on (a) a material consisting of synthetic speech and (b) voice recordings of depressed patients who were examined during depression and after improvement.
Mackie, Iain D; DiLabio, Gino A
2011-10-07
The first-principles calculation of non-covalent (particularly dispersion) interactions between molecules is a considerable challenge. In this work we studied the binding energies for ten small non-covalently bonded dimers with several combinations of correlation methods (MP2, coupled-cluster single double, coupled-cluster single double (triple) (CCSD(T))), correlation-consistent basis sets (aug-cc-pVXZ, X = D, T, Q), two-point complete basis set energy extrapolations, and counterpoise corrections. For this work, complete basis set results were estimated from averaged counterpoise and non-counterpoise-corrected CCSD(T) binding energies obtained from extrapolations with aug-cc-pVQZ and aug-cc-pVTZ basis sets. It is demonstrated that, in almost all cases, binding energies converge more rapidly to the basis set limit by averaging the counterpoise and non-counterpoise corrected values than by using either counterpoise or non-counterpoise methods alone. Examination of the effect of basis set size and electron correlation shows that the triples contribution to the CCSD(T) binding energies is fairly constant with the basis set size, with a slight underestimation with CCSD(T)∕aug-cc-pVDZ compared to the value at the (estimated) complete basis set limit, and that contributions to the binding energies obtained by MP2 generally overestimate the analogous CCSD(T) contributions. Taking these factors together, we conclude that the binding energies for non-covalently bonded systems can be accurately determined using a composite method that combines CCSD(T)∕aug-cc-pVDZ with energy corrections obtained using basis set extrapolated MP2 (utilizing aug-cc-pVQZ and aug-cc-pVTZ basis sets), if all of the components are obtained by averaging the counterpoise and non-counterpoise energies. With such an approach, binding energies for the set of ten dimers are predicted with a mean absolute deviation of 0.02 kcal/mol, a maximum absolute deviation of 0.05 kcal/mol, and a mean percent absolute deviation of only 1.7%, relative to the (estimated) complete basis set CCSD(T) results. Use of this composite approach to an additional set of eight dimers gave binding energies to within 1% of previously published high-level data. It is also shown that binding within parallel and parallel-crossed conformations of naphthalene dimer is predicted by the composite approach to be 9% greater than that previously reported in the literature. The ability of some recently developed dispersion-corrected density-functional theory methods to predict the binding energies of the set of ten small dimers was also examined. © 2011 American Institute of Physics
Development of a Dual-Pump CARS System for Measurements in a Supersonic Combusting Free Jet
NASA Technical Reports Server (NTRS)
Magnotti, Gaetano; Cutler, Andrew D.; Danehy, Paul
2012-01-01
This work describes the development of a dual-pump CARS system for simultaneous measurements of temperature and absolute mole fraction of N2, O2 and H2 in a laboratory scale supersonic combusting free jet. Changes to the experimental set-up and the data analysis to improve the quality of the measurements in this turbulent, high-temperature reacting flow are described. The accuracy and precision of the instrument have been determined using data collected in a Hencken burner flame. For temperature above 800 K, errors in absolute mole fraction are within 1.5, 0.5, and 1% of the total composition for N2, O2 and H2, respectively. Estimated standard deviations based on 500 single shots are between 10 and 65 K for the temperature, between 0.5 and 1.7% of the total composition for O2, and between 1.5 and 3.4% for N2. The standard deviation of H2 is 10% of the average measured mole fraction. Results obtained in the jet with and without combustion are illustrated, and the capabilities and limitations of the dual-pump CARS instrument discussed.
Predicting Accommodative Response Using Paraxial Schematic Eye Models
Ramasubramanian, Viswanathan; Glasser, Adrian
2016-01-01
Purpose Prior ultrasound biomicroscopy (UBM) studies showed that accommodative optical response (AOR) can be predicted from accommodative biometric changes in a young and a pre-presbyopic population from linear relationships between accommodative optical and biometric changes, with a standard deviation of less than 0.55D. Here, paraxial schematic eyes (SE) were constructed from measured accommodative ocular biometry parameters to see if predictions are improved. Methods Measured ocular biometry (OCT, A-scan and UBM) parameters from 24 young and 24 pre-presbyopic subjects were used to construct paraxial SEs for each individual subject (individual SEs) for three different lens equivalent refractive index methods. Refraction and AOR calculated from the individual SEs were compared with Grand Seiko (GS) autorefractor measured refraction and AOR. Refraction and AOR were also calculated from individual SEs constructed using the average population accommodative change in UBM measured parameters (average SEs). Results Schematic eye calculated and GS measured AOR were linearly related (young subjects: slope = 0.77; r2 = 0.86; pre-presbyopic subjects: slope = 0.64; r2 = 0.55). The mean difference in AOR (GS - individual SEs) for the young subjects was −0.27D and for the pre-presbyopic subjects was 0.33D. For individual SEs, the mean ± SD of the absolute differences in AOR between the GS and SEs was 0.50 ± 0.39D for the young subjects and 0.50 ± 0.37D for the pre-presbyopic subjects. For average SEs, the mean ± SD of the absolute differences in AOR between the GS and the SEs was 0.77 ± 0.88D for the young subjects and 0.51 ± 0.49D for the pre-presbyopic subjects. Conclusions Individual paraxial SEs predict AOR, on average, with a standard deviation of 0.50D in young and pre-presbyopic subject populations. Although this prediction is only marginally better than from individual linear regressions, it does consider all the ocular biometric parameters. PMID:27092928
NASA Technical Reports Server (NTRS)
Cardelli, Jason A.; Clayton, Geoffrey C.
1991-01-01
The range of validity of the average absolute extinction law (AAEL) proposed by Cardelli et al. (1988 and 1989) is investigated, combining published visible and NIR data with IUE UV observations for three lines of sight through dense dark cloud environments with high values of total-to-selective extinction. The characteristics of the data sets and the reduction and parameterization methods applied are described in detail, and the results are presented in extensive tables and graphs. Good agreement with the AAEL is demonstrated for wavelengths from 3.4 microns to 250 nm, but significant deviations are found at shorter wavelengths (where previous studies of lines of sight through bright nebulosity found good agreement with the AAEL). These differences are attributed to the effects of coatings on small-bump and FUV grains.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen, N; Lu, S; Qin, Y
Purpose: To evaluate the dosimetric uncertainty associated with Gafchromic (EBT3) films and establish an absolute dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). Methods: EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields, and standard deviations of dose maps were calculated at each color channel for evaluation. A scanner non-uniform response correction map was built by registering and comparing film doses to the reference diode array-based dose map delivered with the same doses. To determine the temporal dependence of EBT3 films, the average correction factors of differentmore » dose levels as a function of time were evaluated up to four days after irradiation. An integrated film dosimetry protocol was developed for dose calibration, calibration curve fitting, dose mapping, and profile/gamma analysis. Patient specific quality assurance (PSQA) was performed for 93 SRS/SBRT treatment plans. Results: The scanner response varied within 1% for the field sizes less than 5 × 5 cm{sup 2}, and up to 5% for the field sizes of 10 × 10 cm{sup 2}. The scanner correction method was able to remove visually evident, irregular detector responses found for larger field sizes. The dose response of the film changed rapidly (∼10%) in the first two hours and plateaued afterwards, ∼3% change between 2 and 24 hours. The mean uncertainties (mean of the standard deviations) were <0.5% over the dose range 1∼15Gy for all color channels for the OD response curves. The percentage of points passing the 3%/1mm gamma criteria based on absolute dose analysis, averaged over all tests, was 95.0 ± 4.2. Conclusion: We have developed an absolute film dose dosimetry protocol using EBT3 films. The overall uncertainty has been established to be approximately 1% for SRS and SBRT PSQA. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, You; Yin, Fang-Fang; Ren, Lei, E-mail: lei.ren@duke.edu
2015-08-15
Purpose: Lung cancer treatment is susceptible to treatment errors caused by interfractional anatomical and respirational variations of the patient. On-board treatment dose verification is especially critical for the lung stereotactic body radiation therapy due to its high fractional dose. This study investigates the feasibility of using cone-beam (CB)CT images estimated by a motion modeling and free-form deformation (MM-FD) technique for on-board dose verification. Methods: Both digital and physical phantom studies were performed. Various interfractional variations featuring patient motion pattern change, tumor size change, and tumor average position change were simulated from planning CT to on-board images. The doses calculated onmore » the planning CT (planned doses), the on-board CBCT estimated by MM-FD (MM-FD doses), and the on-board CBCT reconstructed by the conventional Feldkamp-Davis-Kress (FDK) algorithm (FDK doses) were compared to the on-board dose calculated on the “gold-standard” on-board images (gold-standard doses). The absolute deviations of minimum dose (ΔD{sub min}), maximum dose (ΔD{sub max}), and mean dose (ΔD{sub mean}), and the absolute deviations of prescription dose coverage (ΔV{sub 100%}) were evaluated for the planning target volume (PTV). In addition, 4D on-board treatment dose accumulations were performed using 4D-CBCT images estimated by MM-FD in the physical phantom study. The accumulated doses were compared to those measured using optically stimulated luminescence (OSL) detectors and radiochromic films. Results: Compared with the planned doses and the FDK doses, the MM-FD doses matched much better with the gold-standard doses. For the digital phantom study, the average (± standard deviation) ΔD{sub min}, ΔD{sub max}, ΔD{sub mean}, and ΔV{sub 100%} (values normalized by the prescription dose or the total PTV) between the planned and the gold-standard PTV doses were 32.9% (±28.6%), 3.0% (±2.9%), 3.8% (±4.0%), and 15.4% (±12.4%), respectively. The corresponding values of FDK PTV doses were 1.6% (±1.9%), 1.2% (±0.6%), 2.2% (±0.8%), and 17.4% (±15.3%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.3% (±0.2%), 0.9% (±0.6%), 0.6% (±0.4%), and 1.0% (±0.8%), respectively. Similarly, for the physical phantom study, the average ΔD{sub min}, ΔD{sub max}, ΔD{sub mean}, and ΔV{sub 100%} of planned PTV doses were 38.1% (±30.8%), 3.5% (±5.1%), 3.0% (±2.6%), and 8.8% (±8.0%), respectively. The corresponding values of FDK PTV doses were 5.8% (±4.5%), 1.6% (±1.6%), 2.0% (±0.9%), and 9.3% (±10.5%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.4% (±0.8%), 0.8% (±1.0%), 0.5% (±0.4%), and 0.8% (±0.8%), respectively. For the 4D dose accumulation study, the average (± standard deviation) absolute dose deviation (normalized by local doses) between the accumulated doses and the OSL measured doses was 3.3% (±2.7%). The average gamma index (3%/3 mm) between the accumulated doses and the radiochromic film measured doses was 94.5% (±2.5%). Conclusions: MM-FD estimated 4D-CBCT enables accurate on-board dose calculation and accumulation for lung radiation therapy. It can potentially be valuable for treatment quality assessment and adaptive radiation therapy.« less
Mirkhani, Seyyed Alireza; Gharagheizi, Farhad; Sattari, Mehdi
2012-03-01
Evaluation of diffusion coefficients of pure compounds in air is of great interest for many diverse industrial and air quality control applications. In this communication, a QSPR method is applied to predict the molecular diffusivity of chemical compounds in air at 298.15K and atmospheric pressure. Four thousand five hundred and seventy nine organic compounds from broad spectrum of chemical families have been investigated to propose a comprehensive and predictive model. The final model is derived by Genetic Function Approximation (GFA) and contains five descriptors. Using this dedicated model, we obtain satisfactory results quantified by the following statistical results: Squared Correlation Coefficient=0.9723, Standard Deviation Error=0.003 and Average Absolute Relative Deviation=0.3% for the predicted properties from existing experimental values. Copyright © 2011 Elsevier Ltd. All rights reserved.
Lin, Yifan; Chen, Gui; Fu, Zhen; Ma, Lian; Li, Weiran
2015-01-01
To evaluate, using cone-beam computed tomography (CBCT), both the condylar-fossa relationships and the mandibular and condylar asymmetries between unilateral cleft lip and palate (UCLP) patients and non-cleft patients with class III skeletal relationship, and to investigate the factors of asymmetry contributing to chin deviation. The UCLP and non-cleft groups consisted of 30 and 40 subjects, respectively, in mixed dentition with class III skeletal relationships. Condylar-fossa relationships and the dimensional and positional asymmetries of the condyles and mandibles were examined using CBCT. Intra-group differences were compared between two sides in both groups using a paired t-test. Furthermore, correlations between each measurement and chin deviation were assessed. It was observed that 90% of UCLP and 67.5% of non-cleft subjects had both condyles centered, and no significant asymmetry was found. The axial angle and the condylar center distances to the midsagittal plane were significantly greater on the cleft side than on the non-cleft side (P=0.001 and P=0.028, respectively) and were positively correlated with chin deviation in the UCLP group. Except for a larger gonial angle on the cleft side, the two groups presented with consistent asymmetries showing shorter mandibular bodies and total mandibular lengths on the cleft (deviated) side. The average chin deviation was 1.63 mm to the cleft side, and the average absolute chin deviation was significantly greater in the UCLP group than in the non-cleft group (P=0.037). Compared with non-cleft subjects with similar class III skeletal relationships, the subjects with UCLP showed more severe lower facial asymmetry. The subjects with UCLP presented with more asymmetrical positions and rotations of the condyles on axial slices, which were positively correlated with chin deviation.
Endo, Takao; Fujikado, Takashi; Hirota, Masakazu; Kanda, Hiroyuki; Morimoto, Takeshi; Nishida, Kohji
2018-04-20
To evaluate the improvement in targeted reaching movements toward targets of various contrasts in a patient implanted with a suprachoroidal-transretinal stimulation (STS) retinal prosthesis. An STS retinal prosthesis was implanted in the right eye of a 42-year-old man with advanced Stargardt disease (visual acuity: right eye, light perception; left eye, hand motion). In localization tests during the 1-year follow-up period, the patient attempted to touch the center of a white square target (visual angle, 10°; contrast, 96, 85, or 74%) displayed at a random position on a monitor. The distance between the touched point and the center of the target (the absolute deviation) was averaged over 20 trials with the STS system on or off. With the left eye occluded, the absolute deviation was not consistently lower with the system on than off for high-contrast (96%) targets, but was consistently lower with the system on for low-contrast (74%) targets. With both eyes open, the absolute deviation was consistently lower with the system on than off for 85%-contrast targets. With the system on and 96%-contrast targets, we detected a shorter response time while covering the right eye, which was being implanted with the STS, compared to covering the left eye (2.41 ± 2.52 vs 8.45 ± 3.78 s, p < 0.01). Performance of a reaching movement improved in a patient with an STS retinal prosthesis implanted in an eye with residual natural vision. Patients with a retinal prosthesis may be able to improve their visual performance by using both artificial vision and their residual natural vision. Beginning date of the trial: Feb. 20, 2014 Date of registration: Jan. 4, 2014 Trial registration number: UMIN000012754 Registration site: UMIN Clinical Trials Registry (UMIN-CTR) http://www.umin.ac.jp/ctr/index.htm.
NASA Technical Reports Server (NTRS)
Maximenko, Nikolai A.
2003-01-01
Mean absolute sea level reflects the deviation of the Ocean surface from geoid due to the ocean currents and is an important characteristic of the dynamical state of the ocean. Values of its spatial variations (order of 1 m) are generally much smaller than deviations of the geoid shape from ellipsoid (order of 100 m) that makes the derivation of the absolute mean sea level a difficult task for gravity and satellite altimetry observations. Technique used by Niiler et al. for computation of the absolute mean sea level in the Kuroshio Extension was then developed into more general method and applied by Niiler et al. (2003b) to the global Ocean. The method is based on the consideration of balance of horizontal momentum.
Wadehn, Federico; Carnal, David; Loeliger, Hans-Andrea
2015-08-01
Heart rate variability is one of the key parameters for assessing the health status of a subject's cardiovascular system. This paper presents a local model fitting algorithm used for finding single heart beats in photoplethysmogram recordings. The local fit of exponentially decaying cosines of frequencies within the physiological range is used to detect the presence of a heart beat. Using 42 subjects from the CapnoBase database, the average heart rate error was 0.16 BPM and the standard deviation of the absolute estimation error was 0.24 BPM.
NASA Astrophysics Data System (ADS)
Liu, Weibo; Jin, Yan; Price, Mark
2016-10-01
A new heuristic based on the Nawaz-Enscore-Ham algorithm is proposed in this article for solving a permutation flow-shop scheduling problem. A new priority rule is proposed by accounting for the average, mean absolute deviation, skewness and kurtosis, in order to fully describe the distribution style of processing times. A new tie-breaking rule is also introduced for achieving effective job insertion with the objective of minimizing both makespan and machine idle time. Statistical tests illustrate better solution quality of the proposed algorithm compared to existing benchmark heuristics.
Donald, William A; Leib, Ryan D; O'Brien, Jeremy T; Williams, Evan R
2009-06-08
Solution-phase, half-cell potentials are measured relative to other half-cell potentials, resulting in a thermochemical ladder that is anchored to the standard hydrogen electrode (SHE), which is assigned an arbitrary value of 0 V. A new method for measuring the absolute SHE potential is demonstrated in which gaseous nanodrops containing divalent alkaline-earth or transition-metal ions are reduced by thermally generated electrons. Energies for the reactions 1) M(H(2)O)(24)(2+)(g) + e(-)(g)-->M(H(2)O)(24)(+)(g) and 2) M(H(2)O)(24)(2+)(g) + e(-)(g)-->MOH(H(2)O)(23)(+)(g) + H(g) and the hydrogen atom affinities of MOH(H(2)O)(23)(+)(g) are obtained from the number of water molecules lost through each pathway. From these measurements on clusters containing nine different metal ions and known thermochemical values that include solution hydrolysis energies, an average absolute SHE potential of +4.29 V vs. e(-)(g) (standard deviation of 0.02 V) and a real proton solvation free energy of -265 kcal mol(-1) are obtained. With this method, the absolute SHE potential can be obtained from a one-electron reduction of nanodrops containing divalent ions that are not observed to undergo one-electron reduction in aqueous solution.
Donald, William A.; Leib, Ryan D.; O’Brien, Jeremy T.; Williams, Evan R.
2009-01-01
Solution-phase, half-cell potentials are measured relative to other half-cell potentials, resulting in a thermochemical ladder that is anchored to the standard hydrogen electrode (SHE), which is assigned an arbitrary value of 0 V. A new method for measuring the absolute SHE potential is demonstrated in which gaseous nanodrops containing divalent alkaline-earth or transition-metal ions are reduced by thermally generated electrons. Energies for the reactions 1) M-(H2O)242+(g)+e−(g)→M(H2O)24+(g) and 2) M(H2O)242+(g)+e−(g)→MOH(H2O)23+(g)+H(g) and the hydrogen atom affinities of MOH(H2O)23+(g) are obtained from the number of water molecules lost through each pathway. From these measurements on clusters containing nine different metal ions and known thermochemical values that include solution hydrolysis energies, an average absolute SHE potential of +4.29 V vs. e−(g) (standard deviation of 0.02 V) and a real proton solvation free energy of −265 kcal mol−1 are obtained. With this method, the absolute SHE potential can be obtained from a one-electron reduction of nanodrops containing divalent ions that are not observed to undergo one-electron reduction in aqueous solution. PMID:19440999
Heavy Ozone Enrichments from ATMOS Infrared Solar Spectra
NASA Technical Reports Server (NTRS)
Irion, F. W.; Gunson, M. R.; Rinsland, C. P.; Yung, Y. L.; Abrams, M. C.; Chang, A. Y.; Goldman, A.
1996-01-01
Vertical enrichment profiles of stratospheric O-16O-16O-18 and O-16O-18O-16 (hereafter referred to as (668)O3 and (686)O3 respectively) have been derived from space-based solar occultation spectra recorded at 0.01 cm(exp-1) resolution by the ATMOS (Atmospheric Trace MOlecule Spectroscopy) Fourier transform infrared (FTIR) spectrometer. The observations, made during the Spacelab 3 and ATLAS-1, -2, and -3 shuttle missions, cover polar, mid-latitude and tropical regions between 26 to 2.6 mb inclusive (approximately 25 to 41 km). Average enrichments, weighted by molecular (48)O3 density, of (15 +/- 6)% were found for (668)O3 and (10 +/- 7)% for (686)O3. Defining the mixing ratio of (50)O3 as the sum of those for (668)O3 and (686)O3, an enrichment of (13 plus or minus 5)% was found for (50)O3 (1 sigma standard deviation). No latitudinal or vertical gradients were found outside this standard deviation. From a series of ground-based measurements by the ATMOS instrument at Table Mountain, California (34.4 deg N), an average total column (668)O3 enrichment of (17 +/- 4)% (1 sigma standard deviation) was determined, with no significant seasonal variation discernable. Possible biases in the spectral intensities that affect the determination of absolute enrichments are discussed.
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
9 CFR 439.20 - Criteria for maintaining accreditation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... deviation measure equal to zero when the absolute value of the result's standardized difference, (d), is...) Variability: The absolute value of the standardized difference between the accredited laboratory's result and... constant, is used in place of the absolute value of the standardized difference to determine the CUSUM-V...
ERIC Educational Resources Information Center
Helmreich, James E.; Krog, K. Peter
2018-01-01
We present a short, inquiry-based learning course on concepts and methods underlying ordinary least squares (OLS), least absolute deviation (LAD), and quantile regression (QR). Students investigate squared, absolute, and weighted absolute distance functions (metrics) as location measures. Using differential calculus and properties of convex…
NASA Astrophysics Data System (ADS)
Anees, Amir; Khan, Waqar Ahmad; Gondal, Muhammad Asif; Hussain, Iqtadar
2013-07-01
The aim of this work is to make use of the mean of absolute deviation (MAD) method for the evaluation process of substitution boxes used in the advanced encryption standard. In this paper, we use the MAD technique to analyze some popular and prevailing substitution boxes used in encryption processes. In particular, MAD is applied to advanced encryption standard (AES), affine power affine (APA), Gray, Lui J., Residue Prime, S8 AES, SKIPJACK, and Xyi substitution boxes.
NASA Astrophysics Data System (ADS)
Yi, Huili; Tian, Jianxiang
2014-07-01
A new simple correlation based on the principle of corresponding state is proposed to estimate the temperature-dependent surface tension of normal saturated liquids. The correlation is a linear one and strongly stands for 41 saturated normal liquids. The new correlation requires only the triple point temperature, triple point surface tension and critical point temperature as input and is able to represent the experimental surface tension data for these 41 saturated normal liquids with a mean absolute average percent deviation of 1.26% in the temperature regions considered. For most substances, the temperature covers the range from the triple temperature to the one beyond the boiling temperature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manaa, M. Riad; Fried, Laurence E.; Kuo, I-Feng W.
We report gas-phase enthalpies of formation for the set of energetic molecules NTO, DADE, LLM-105, TNT, RDX, TATB, HMX, and PETN using the G2, G3, G4, and ccCA-PS3 quantum composite methods. Calculations for HMX and PETN hitherto represent the largest molecules attempted with these methods. G3 and G4 calculations are typically close to one another, with a larger difference found between these methods and ccCA-PS3. Furthermore there is significant uncertainty in experimental values, the mean absolute deviation between the average experimental value and calculations are 12, 6, 7, and 3 kcal/mol for G2, G3, G4, and ccCA-PS3, respectively.
Støre-Valen, Jakob; Ryum, Truls; Pedersen, Geir A F; Pripp, Are H; Jose, Paul E; Karterud, Sigmund
2015-09-01
The Global Assessment of Functioning (GAF) Scale is used in routine clinical practice and research to estimate symptom and functional severity and longitudinal change. Concerns about poor interrater reliability have been raised, and the present study evaluated the effect of a Web-based GAF training program designed to improve interrater reliability in routine clinical practice. Clinicians rated up to 20 vignettes online, and received deviation scores as immediate feedback (i.e., own scores compared with expert raters) after each rating. Growth curves of absolute SD scores across the vignettes were modeled. A linear mixed effects model, using the clinician's deviation scores from expert raters as the dependent variable, indicated an improvement in reliability during training. Moderation by content of scale (symptoms; functioning), scale range (average; extreme), previous experience with GAF rating, profession, and postgraduate training were assessed. Training reduced deviation scores for inexperienced GAF raters, for individuals in clinical professions other than nursing and medicine, and for individuals with no postgraduate specialization. In addition, training was most beneficial for cases with average severity of symptoms compared with cases with extreme severity. The results support the use of Web-based training with feedback routines as a means to improve the reliability of GAF ratings performed by clinicians in mental health practice. These results especially pertain to clinicians in mental health practice who do not have a masters or doctoral degree. (c) 2015 APA, all rights reserved.
In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.
Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J
2004-01-01
In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.
Yuan, Peng; Mai, Huaming; Li, Jianfu; Ho, Dennis Chun-Yu; Lai, Yingying; Liu, Siting; Kim, Daeseung; Xiong, Zixiang; Alfi, David M; Teichgraeber, John F; Gateno, Jaime; Xia, James J
2017-12-01
There are many proven problems associated with traditional surgical planning methods for orthognathic surgery. To address these problems, we developed a computer-aided surgical simulation (CASS) system, the AnatomicAligner, to plan orthognathic surgery following our streamlined clinical protocol. The system includes six modules: image segmentation and three-dimensional (3D) reconstruction, registration and reorientation of models to neutral head posture, 3D cephalometric analysis, virtual osteotomy, surgical simulation, and surgical splint generation. The accuracy of the system was validated in a stepwise fashion: first to evaluate the accuracy of AnatomicAligner using 30 sets of patient data, then to evaluate the fitting of splints generated by AnatomicAligner using 10 sets of patient data. The industrial gold standard system, Mimics, was used as the reference. When comparing the results of segmentation, virtual osteotomy and transformation achieved with AnatomicAligner to the ones achieved with Mimics, the absolute deviation between the two systems was clinically insignificant. The average surface deviation between the two models after 3D model reconstruction in AnatomicAligner and Mimics was 0.3 mm with a standard deviation (SD) of 0.03 mm. All the average surface deviations between the two models after virtual osteotomy and transformations were smaller than 0.01 mm with a SD of 0.01 mm. In addition, the fitting of splints generated by AnatomicAligner was at least as good as the ones generated by Mimics. We successfully developed a CASS system, the AnatomicAligner, for planning orthognathic surgery following the streamlined planning protocol. The system has been proven accurate. AnatomicAligner will soon be available freely to the boarder clinical and research communities.
Preconditioning of Interplanetary Space Due to Transient CME Disturbances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Temmer, M.; Reiss, M. A.; Hofmeister, S. J.
Interplanetary space is characteristically structured mainly by high-speed solar wind streams emanating from coronal holes and transient disturbances such as coronal mass ejections (CMEs). While high-speed solar wind streams pose a continuous outflow, CMEs abruptly disrupt the rather steady structure, causing large deviations from the quiet solar wind conditions. For the first time, we give a quantification of the duration of disturbed conditions (preconditioning) for interplanetary space caused by CMEs. To this aim, we investigate the plasma speed component of the solar wind and the impact of in situ detected interplanetary CMEs (ICMEs), compared to different background solar wind modelsmore » (ESWF, WSA, persistence model) for the time range 2011–2015. We quantify in terms of standard error measures the deviations between modeled background solar wind speed and observed solar wind speed. Using the mean absolute error, we obtain an average deviation for quiet solar activity within a range of 75.1–83.1 km s{sup −1}. Compared to this baseline level, periods within the ICME interval showed an increase of 18%–32% above the expected background, and the period of two days after the ICME displayed an increase of 9%–24%. We obtain a total duration of enhanced deviations over about three and up to six days after the ICME start, which is much longer than the average duration of an ICME disturbance itself (∼1.3 days), concluding that interplanetary space needs ∼2–5 days to recover from the impact of ICMEs. The obtained results have strong implications for studying CME propagation behavior and also for space weather forecasting.« less
Yuan, Peng; Mai, Huaming; Li, Jianfu; Ho, Dennis Chun-Yu; Lai, Yingying; Liu, Siting; Kim, Daeseung; Xiong, Zixiang; Alfi, David M.; Teichgraeber, John F.; Gateno, Jaime
2017-01-01
Purpose There are many proven problems associated with traditional surgical planning methods for orthognathic surgery. To address these problems, we developed a computer-aided surgical simulation (CASS) system, the AnatomicAligner, to plan orthognathic surgery following our streamlined clinical protocol. Methods The system includes six modules: image segmentation and three-dimensional (3D) reconstruction, registration and reorientation of models to neutral head posture, 3D cephalometric analysis, virtual osteotomy, surgical simulation, and surgical splint generation. The accuracy of the system was validated in a stepwise fashion: first to evaluate the accuracy of AnatomicAligner using 30 sets of patient data, then to evaluate the fitting of splints generated by AnatomicAligner using 10 sets of patient data. The industrial gold standard system, Mimics, was used as the reference. Result When comparing the results of segmentation, virtual osteotomy and transformation achieved with AnatomicAligner to the ones achieved with Mimics, the absolute deviation between the two systems was clinically insignificant. The average surface deviation between the two models after 3D model reconstruction in AnatomicAligner and Mimics was 0.3 mm with a standard deviation (SD) of 0.03 mm. All the average surface deviations between the two models after virtual osteotomy and transformations were smaller than 0.01 mm with a SD of 0.01 mm. In addition, the fitting of splints generated by AnatomicAligner was at least as good as the ones generated by Mimics. Conclusion We successfully developed a CASS system, the AnatomicAligner, for planning orthognathic surgery following the streamlined planning protocol. The system has been proven accurate. AnatomicAligner will soon be available freely to the boarder clinical and research communities. PMID:28432489
Interactive Visual Least Absolutes Method: Comparison with the Least Squares and the Median Methods
ERIC Educational Resources Information Center
Kim, Myung-Hoon; Kim, Michelle S.
2016-01-01
A visual regression analysis using the least absolutes method (LAB) was developed, utilizing an interactive approach of visually minimizing the sum of the absolute deviations (SAB) using a bar graph in Excel; the results agree very well with those obtained from nonvisual LAB using a numerical Solver in Excel. These LAB results were compared with…
Viscosities of aqueous blended amines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, C.H.; Li, M.H.
1997-07-01
Solutions of alkanolamines are an industrially important class of compounds used in the natural gas, oil refineries, petroleum chemical plants, and synthetic ammonia industries for the removal of acidic components like CO{sub 2} and H{sub 2}S from gas streams. The viscosities of aqueous mixtures of diethanolamine (DEA) + N-methyldiethanolamine (MDEA), DEA + 2-amino-2-methyl-1-propanol (AMP), and monoethanolamine (MEA) + 2-piperidineethanol (2-PE) were measured from 30 C to 80 C. A Redlich-Kister equation for the viscosity deviation was applied to represent the viscosity. On the basis of the available viscosity data for five ternary systems, MEA + MDEA + H{sub 2}O, MEAmore » + AMP + H{sub 2}O, DEA + MDEA + H{sub 2}O, DEA + AMP + H{sub 2}O, and MEA + 2-PE + H{sub 2}O, a generalized set of binary parameters were determined. For the viscosity calculation of the systems tested, the overall average absolute percent deviation is about 1.0% for a total of 499 data points.« less
Forecast of Frost Days Based on Monthly Temperatures
NASA Astrophysics Data System (ADS)
Castellanos, M. T.; Tarquis, A. M.; Morató, M. C.; Saa-Requejo, A.
2009-04-01
Although frost can cause considerable crop damage and mitigation practices against forecasted frost exist, frost forecasting technologies have not changed for many years. The paper reports a new method to forecast the monthly number of frost days (FD) for several meteorological stations at Community of Madrid (Spain) based on successive application of two models. The first one is a stochastic model, autoregressive integrated moving average (ARIMA), that forecasts monthly minimum absolute temperature (tmin) and monthly average of minimum temperature (tminav) following Box-Jenkins methodology. The second model relates these monthly temperatures to minimum daily temperature distribution during one month. Three ARIMA models were identified for the time series analyzed with a stational period correspondent to one year. They present the same stational behavior (moving average differenced model) and different non-stational part: autoregressive model (Model 1), moving average differenced model (Model 2) and autoregressive and moving average model (Model 3). At the same time, the results point out that minimum daily temperature (tdmin), for the meteorological stations studied, followed a normal distribution each month with a very similar standard deviation through years. This standard deviation obtained for each station and each month could be used as a risk index for cold months. The application of Model 1 to predict minimum monthly temperatures showed the best FD forecast. This procedure provides a tool for crop managers and crop insurance companies to asses the risk of frost frequency and intensity, so that they can take steps to mitigate against frost damage and estimated the damage that frost would cost. This research was supported by Comunidad de Madrid Research Project 076/92. The cooperation of the Spanish National Meteorological Institute and the Spanish Ministerio de Agricultura, Pesca y Alimentation (MAPA) is gratefully acknowledged.
Georg, Dietmar; Stock, Markus; Kroupa, Bernhard; Olofsson, Jörgen; Nyholm, Tufve; Ahnesjö, Anders; Karlsson, Mikael
2007-08-21
Experimental methods are commonly used for patient-specific intensity-modulated radiotherapy (IMRT) verification. The purpose of this study was to investigate the accuracy and performance of independent dose calculation software (denoted as 'MUV' (monitor unit verification)) for patient-specific quality assurance (QA). 52 patients receiving step-and-shoot IMRT were considered. IMRT plans were recalculated by the treatment planning systems (TPS) in a dedicated QA phantom, in which an experimental 1D and 2D verification (0.3 cm(3) ionization chamber; films) was performed. Additionally, an independent dose calculation was performed. The fluence-based algorithm of MUV accounts for collimator transmission, rounded leaf ends, tongue-and-groove effect, backscatter to the monitor chamber and scatter from the flattening filter. The dose calculation utilizes a pencil beam model based on a beam quality index. DICOM RT files from patient plans, exported from the TPS, were directly used as patient-specific input data in MUV. For composite IMRT plans, average deviations in the high dose region between ionization chamber measurements and point dose calculations performed with the TPS and MUV were 1.6 +/- 1.2% and 0.5 +/- 1.1% (1 S.D.). The dose deviations between MUV and TPS slightly depended on the distance from the isocentre position. For individual intensity-modulated beams (total 367), an average deviation of 1.1 +/- 2.9% was determined between calculations performed with the TPS and with MUV, with maximum deviations up to 14%. However, absolute dose deviations were mostly less than 3 cGy. Based on the current results, we aim to apply a confidence limit of 3% (with respect to the prescribed dose) or 6 cGy for routine IMRT verification. For off-axis points at distances larger than 5 cm and for low dose regions, we consider 5% dose deviation or 10 cGy acceptable. The time needed for an independent calculation compares very favourably with the net time for an experimental approach. The physical effects modelled in the dose calculation software MUV allow accurate dose calculations in individual verification points. Independent calculations may be used to replace experimental dose verification once the IMRT programme is mature.
Nebuya, S; Noshiro, M; Yonemoto, A; Tateno, S; Brown, B H; Smallwood, R H; Milnes, P
2006-05-01
Inter-subject variability has caused the majority of previous electrical impedance tomography (EIT) techniques to focus on the derivation of relative or difference measures of in vivo tissue resistivity. Implicit in these techniques is the requirement for a reference or previously defined data set. This study assesses the accuracy and optimum electrode placement strategy for a recently developed method which estimates an absolute value of organ resistivity without recourse to a reference data set. Since this measurement of tissue resistivity is absolute, in Ohm metres, it should be possible to use EIT measurements for the objective diagnosis of lung diseases such as pulmonary oedema and emphysema. However, the stability and reproducibility of the method have not yet been investigated fully. To investigate these problems, this study used a Sheffield Mk3.5 system which was configured to operate with eight measurement electrodes. As a result of this study, the absolute resistivity measurement was found to be insensitive to the electrode level between 4 and 5 cm above the xiphoid process. The level of the electrode plane was varied between 2 cm and 7 cm above the xiphoid process. Absolute lung resistivity in 18 normal subjects (age 22.6 +/- 4.9, height 169.1 +/- 5.7 cm, weight 60.6 +/- 4.5 kg, body mass index 21.2 +/- 1.6: mean +/- standard deviation) was measured during both normal and deep breathing for 1 min. Three sets of measurements were made over a period of several days on each of nine of the normal male subjects. No significant differences in absolute lung resistivity were found, either during normal tidal breathing between the electrode levels of 4 and 5 cm (9.3 +/- 2.4 Omega m, 9.6 +/- 1.9 Omega m at 4 and 5 cm, respectively: mean +/- standard deviation) or during deep breathing between the electrode levels of 4 and 5 cm (10.9 +/- 2.9 Omega m and 11.1 +/- 2.3 Omega m, respectively: mean +/- standard deviation). However, the differences in absolute lung resistivity between normal and deep tidal breathing at the same electrode level are significant. No significant difference was found in the coefficient of variation between the electrode levels of 4 and 5 cm (9.5 +/- 3.6%, 8.5 +/- 3.2% at 4 and 5 cm, respectively: mean +/- standard deviation in individual subjects). Therefore, the electrode levels of 4 and 5 cm above the xiphoid process showed reasonable reliability in the measurement of absolute lung resistivity both among individuals and over time.
Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance.
Atieh, Mohammad A; Ritter, André V; Ko, Ching-Chang; Duqum, Ibrahim
2017-09-01
Trueness and precision are used to evaluate the accuracy of intraoral optical impressions. Although the in vivo precision of intraoral optical impressions has been reported, in vivo trueness has not been evaluated because of limitations in the available protocols. The purpose of this clinical study was to compare the accuracy (trueness and precision) of optical and conventional impressions by using a novel study design. Five study participants consented and were enrolled. For each participant, optical and conventional (vinylsiloxanether) impressions of a custom-made intraoral Co-Cr alloy reference appliance fitted to the mandibular arch were obtained by 1 operator. Three-dimensional (3D) digital models were created for stone casts obtained from the conventional impression group and for the reference appliances by using a validated high-accuracy reference scanner. For the optical impression group, 3D digital models were obtained directly from the intraoral scans. The total mean trueness of each impression system was calculated by averaging the mean absolute deviations of the impression replicates from their 3D reference model for each participant, followed by averaging the obtained values across all participants. The total mean precision for each impression system was calculated by averaging the mean absolute deviations between all the impression replicas for each participant (10 pairs), followed by averaging the obtained values across all participants. Data were analyzed using repeated measures ANOVA (α=.05), first to assess whether a systematic difference in trueness or precision of replicate impressions could be found among participants and second to assess whether the mean trueness and precision values differed between the 2 impression systems. Statistically significant differences were found between the 2 impression systems for both mean trueness (P=.010) and mean precision (P=.007). Conventional impressions had higher accuracy with a mean trueness of 17.0 ±6.6 μm and mean precision of 16.9 ±5.8 μm than optical impressions with a mean trueness of 46.2 ±11.4 μm and mean precision of 61.1 ±4.9 μm. Complete arch (first molar-to-first molar) optical impressions were less accurate than conventional impressions but may be adequate for quadrant impressions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Yeh, Wei-Chang
Network reliability is an important index to the provision of useful information for decision support in the modern world. There is always a need to calculate symbolic network reliability functions (SNRFs) due to dynamic and rapid changes in network parameters. In this brief, the proposed squeezed artificial neural network (SqANN) approach uses the Monte Carlo simulation to estimate the corresponding reliability of a given designed matrix from the Box-Behnken design, and then the Taguchi method is implemented to find the appropriate number of neurons and activation functions of the hidden layer and the output layer in ANN to evaluate SNRFs. According to the experimental results of the benchmark networks, the comparison appears to support the superiority of the proposed SqANN method over the traditional ANN-based approach with at least 16.6% improvement in the median absolute deviation in the cost of extra 2 s on average for all experiments.Network reliability is an important index to the provision of useful information for decision support in the modern world. There is always a need to calculate symbolic network reliability functions (SNRFs) due to dynamic and rapid changes in network parameters. In this brief, the proposed squeezed artificial neural network (SqANN) approach uses the Monte Carlo simulation to estimate the corresponding reliability of a given designed matrix from the Box-Behnken design, and then the Taguchi method is implemented to find the appropriate number of neurons and activation functions of the hidden layer and the output layer in ANN to evaluate SNRFs. According to the experimental results of the benchmark networks, the comparison appears to support the superiority of the proposed SqANN method over the traditional ANN-based approach with at least 16.6% improvement in the median absolute deviation in the cost of extra 2 s on average for all experiments.
Estimating Accuracy of Land-Cover Composition From Two-Stage Clustering Sampling
Land-cover maps are often used to compute land-cover composition (i.e., the proportion or percent of area covered by each class), for each unit in a spatial partition of the region mapped. We derive design-based estimators of mean deviation (MD), mean absolute deviation (MAD), ...
Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration
NASA Astrophysics Data System (ADS)
Sabet, Mahsheed; Rowshanfarzad, Pejman; Vial, Philip; Menk, Frederick W.; Greer, Peter B.
2012-08-01
In this study an amorphous silicon electronic portal imaging device (a-Si EPID) converted to direct detection configuration was investigated as a transit dosimeter for intensity modulated radiation therapy (IMRT). After calibration to dose and correction for a background offset signal, the EPID-measured absolute IMRT transit doses for 29 fields were compared to a MatriXX two-dimensional array of ionization chambers (as reference) using Gamma evaluation (3%, 3 mm). The MatriXX was first evaluated as reference for transit dosimetry. The accuracy of EPID measurements was also investigated by comparison of point dose measurements by an ionization chamber on the central axis with slab and anthropomorphic phantoms in a range of simple to complex fields. The uncertainty in ionization chamber measurements in IMRT fields was also investigated by its displacement from the central axis and comparison with the central axis measurements. Comparison of the absolute doses measured by the EPID and MatriXX with slab phantoms in IMRT fields showed that on average 96.4% and 97.5% of points had a Gamma index<1 in head and neck and prostate fields, respectively. For absolute dose comparisons with anthropomorphic phantoms, the values changed to an average of 93.6%, 93.7% and 94.4% of points with Gamma index<1 in head and neck, brain and prostate fields, respectively. Point doses measured by the EPID and ionization chamber were within 3% difference for all conditions. The deviations introduced in the response of the ionization chamber in IMRT fields were<1%. The direct EPID performance for transit dosimetry showed that it has the potential to perform accurate, efficient and comprehensive in vivo dosimetry for IMRT.
Evaluation of factors affecting CGMS calibration.
Buckingham, Bruce A; Kollman, Craig; Beck, Roy; Kalajian, Andrea; Fiallo-Scharer, Rosanna; Tansey, Michael J; Fox, Larry A; Wilson, Darrell M; Weinzimer, Stuart A; Ruedy, Katrina J; Tamborlane, William V
2006-06-01
The optimal number/timing of calibrations entered into the CGMS (Medtronic MiniMed, Northridge, CA) continuous glucose monitoring system have not been previously described. Fifty subjects with Type 1 diabetes mellitus (10-18 years old) were hospitalized in a clinical research center for approximately 24 h on two separate days. CGMS and OneTouch Ultra meter (LifeScan, Milpitas, CA) data were obtained. The CGMS was retrospectively recalibrated using the Ultra data varying the number and timing of calibrations. Resulting CGMS values were compared against laboratory reference values. There was a modest improvement in accuracy with increasing number of calibrations. The median relative absolute deviation (RAD) was 14%, 15%, 13%, and 13% when using three, four, five, and seven calibration values, respectively (P < 0.001). Corresponding percentages of CGMS-reference pairs meeting the International Organisation for Standardisation criteria were 66%, 67%, 71%, and 72% (P < 0.001). Nighttime accuracy improved when daytime calibrations (pre-lunch and pre-dinner) were removed leaving only two calibrations at 9 p.m. and 6 a.m. (median difference, -2 vs. -9 mg/dL, P < 0.001; median RAD, 12% vs. 15%, P = 0.001). Accuracy was better on visits where the average absolute rate of glucose change at the times of calibration was lower. On visits with average absolute rates <0.5, 0.5 to <1.0, 1.0 to <1.5, and >or=1.5 mg/dL/min, median RAD values were 13% versus 14% versus 17% versus 19%, respectively (P = 0.05). Although accuracy is slightly improved with more calibrations, the timing of the calibrations appears more important. Modifying the algorithm to put less weight on daytime calibrations for nighttime values and calibrating during times of relative glucose stability may have greater impact on accuracy.
Evaluation of Factors Affecting CGMS Calibration
2006-01-01
Background The optimal number/timing of calibrations entered into the Continuous Glucose Monitoring System (“CGMS”; Medtronic MiniMed, Northridge, CA) have not been previously described. Methods Fifty subjects with T1DM (10–18y) were hospitalized in a clinical research center for ~24h on two separate days. CGMS and OneTouch® Ultra® Meter (“Ultra”; LifeScan, Milpitas, CA) data were obtained. The CGMS was retrospectively recalibrated using the Ultra data varying the number and timing of calibrations. Resulting CGMS values were compared against laboratory reference values. Results There was a modest improvement in accuracy with increasing number of calibrations. The median relative absolute deviation (RAD) was 14%, 15%, 13% and 13% when using 3, 4, 5 and 7 calibration values, respectively (p<0.001). Corresponding percentages of CGMS-reference pairs meeting the ISO criteria were 66%, 67%, 71% and 72% (p<0.001). Nighttime accuracy improved when daytime calibrations (pre-lunch and pre-dinner) were removed leaving only two calibrations at 9p.m. and 6a.m. (median difference: −2 vs. −9mg/dL, p<0.001; median RAD: 12% vs. 15%, p=0.001). Accuracy was better on visits where the average absolute rate of glucose change at the times of calibration was lower. On visits with average absolute rates <0.5, 0.5-<1.0, 1.0-<1.5 and ≥1.5mg/dL/min, median RAD values were 13% vs. 14% vs. 17% vs. 19%, respectively (p=0.05). Conclusions Although accuracy is slightly improved with more calibrations, the timing of the calibrations appears more important. Modifying the algorithm to put less weight on daytime calibrations for nighttime values and calibrating during times of relative glucose stability may have greater impact on accuracy. PMID:16800753
NASA Astrophysics Data System (ADS)
Lahmiri, Salim; Boukadoum, Mounir
2015-08-01
We present a new ensemble system for stock market returns prediction where continuous wavelet transform (CWT) is used to analyze return series and backpropagation neural networks (BPNNs) for processing CWT-based coefficients, determining the optimal ensemble weights, and providing final forecasts. Particle swarm optimization (PSO) is used for finding optimal weights and biases for each BPNN. To capture symmetry/asymmetry in the underlying data, three wavelet functions with different shapes are adopted. The proposed ensemble system was tested on three Asian stock markets: The Hang Seng, KOSPI, and Taiwan stock market data. Three statistical metrics were used to evaluate the forecasting accuracy; including, mean of absolute errors (MAE), root mean of squared errors (RMSE), and mean of absolute deviations (MADs). Experimental results showed that our proposed ensemble system outperformed the individual CWT-ANN models each with different wavelet function. In addition, the proposed ensemble system outperformed the conventional autoregressive moving average process. As a result, the proposed ensemble system is suitable to capture symmetry/asymmetry in financial data fluctuations for better prediction accuracy.
Design for the optical retardation in broadband zero-order half-wave plates.
Liu, Jin; Cai, Yi; Chen, Hongyi; Zeng, Xuanke; Zou, Da; Xu, Shixiang
2011-04-25
This paper presents a novel design for broadband zero-order half-wave plates to eliminate the first-order or up to second-order wavelength-dependent birefringent phase retardation (BPR) with 2 or 3 different birefringent materials. The residual BPRs of the plates increase monotonously with the wavelength deviation from a selected wavelength, so the plates are applicable to the broadband light pulses which gather most of the light energy around their central wavelengths. The model chooses the materials by the birefringent dispersion coefficient and evaluates the performances of the plates by the weighted average of the absolute value of residual BPR in order to emphasize the contributions of the incident spectral components whose possess higher energies.
Manaa, M. Riad; Fried, Laurence E.; Kuo, I-Feng W.
2016-02-01
We report gas-phase enthalpies of formation for the set of energetic molecules NTO, DADE, LLM-105, TNT, RDX, TATB, HMX, and PETN using the G2, G3, G4, and ccCA-PS3 quantum composite methods. Calculations for HMX and PETN hitherto represent the largest molecules attempted with these methods. G3 and G4 calculations are typically close to one another, with a larger difference found between these methods and ccCA-PS3. Furthermore there is significant uncertainty in experimental values, the mean absolute deviation between the average experimental value and calculations are 12, 6, 7, and 3 kcal/mol for G2, G3, G4, and ccCA-PS3, respectively.
Detection of Epileptic Seizure Event and Onset Using EEG
Ahammad, Nabeel; Fathima, Thasneem; Joseph, Paul
2014-01-01
This study proposes a method of automatic detection of epileptic seizure event and onset using wavelet based features and certain statistical features without wavelet decomposition. Normal and epileptic EEG signals were classified using linear classifier. For seizure event detection, Bonn University EEG database has been used. Three types of EEG signals (EEG signal recorded from healthy volunteer with eye open, epilepsy patients in the epileptogenic zone during a seizure-free interval, and epilepsy patients during epileptic seizures) were classified. Important features such as energy, entropy, standard deviation, maximum, minimum, and mean at different subbands were computed and classification was done using linear classifier. The performance of classifier was determined in terms of specificity, sensitivity, and accuracy. The overall accuracy was 84.2%. In the case of seizure onset detection, the database used is CHB-MIT scalp EEG database. Along with wavelet based features, interquartile range (IQR) and mean absolute deviation (MAD) without wavelet decomposition were extracted. Latency was used to study the performance of seizure onset detection. Classifier gave a sensitivity of 98.5% with an average latency of 1.76 seconds. PMID:24616892
Characterizing Accuracy and Precision of Glucose Sensors and Meters
2014-01-01
There is need for a method to describe precision and accuracy of glucose measurement as a smooth continuous function of glucose level rather than as a step function for a few discrete ranges of glucose. We propose and illustrate a method to generate a “Glucose Precision Profile” showing absolute relative deviation (ARD) and /or %CV versus glucose level to better characterize measurement errors at any glucose level. We examine the relationship between glucose measured by test and comparator methods using linear regression. We examine bias by plotting deviation = (test – comparator method) versus glucose level. We compute the deviation, absolute deviation (AD), ARD, and standard deviation (SD) for each data pair. We utilize curve smoothing procedures to minimize the effects of random sampling variability to facilitate identification and display of the underlying relationships between ARD or %CV and glucose level. AD, ARD, SD, and %CV display smooth continuous relationships versus glucose level. Estimates of MARD and %CV are subject to relatively large errors in the hypoglycemic range due in part to a markedly nonlinear relationship with glucose level and in part to the limited number of observations in the hypoglycemic range. The curvilinear relationships of ARD and %CV versus glucose level are helpful when characterizing and comparing the precision and accuracy of glucose sensors and meters. PMID:25037194
NASA Technical Reports Server (NTRS)
Dlugach, Janna M.; Mishchenko, Michael I.
2014-01-01
By using the results of highly accurate T-matrix computations for randomly oriented oblate and prolate spheroids and Chebyshev particles with varying degrees of asphericity, we analyze the effects of a deviation of water-droplet shapes from that of a perfect sphere on the behavior of Lorenz-Mie morphology-dependent resonances of various widths. We demonstrate that the positions and profiles of the resonances can change significantly with increasing asphericity. The absolute degree of asphericity required to suppress a Lorenz-Mie resonance is approximately proportional to the resonance width. Our results imply that numerical averaging of scattering characteristics of real cloud droplets over sizes may rely on a significantly coarser size-parameter resolution than that required for ideal, perfectly spherical particles.
Frequency Measurements of Superradiance from the Strontium Clock Transition
NASA Astrophysics Data System (ADS)
Norcia, Matthew A.; Cline, Julia R. K.; Muniz, Juan A.; Robinson, John M.; Hutson, Ross B.; Goban, Akihisa; Marti, G. Edward; Ye, Jun; Thompson, James K.
2018-04-01
We present the first characterization of the spectral properties of superradiant light emitted from the ultranarrow, 1-mHz-linewidth optical clock transition in an ensemble of cold
Gibbs Energy Additivity Approaches in Estimation of Dynamic Viscosities of n-Alkane-1-ol
NASA Astrophysics Data System (ADS)
Phankosol, S.; Krisnangkura, K.
2017-09-01
Alcohols are solvents for organic and inorganic substances. Dynamic viscosity of liquid is important transport properties. In this study models for estimating n-alkan-1-ol dynamic viscosities are correlated to the Martin’s rule of free energy additivity. Data available in literatures are used to validate and support the proposed equations. The dynamic viscosities of n-alkan-1-ol can be easily estimated from its carbon numbers (nc) and temperatures (T). The bias, average absolute deviation and coefficient of determination (R2) in estimating of n-alkan-1-ol are -0.17%, 1.73% and 0.999, respectively. The dynamic viscosities outside temperature between 288.15 and 363.15 K may be possibly estimated by this model but accuracy may be lower.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drzymala, R; Alvarez, P; Bednarz, G
2015-06-15
Purpose: The purpose of this multi-institutional study was to compare two new gamma stereotactic radiosurgery (GSRS) dosimetry protocols to existing calibration methods. The ultimate goal was to guide AAPM Task Group 178 in recommending a standard GSRS dosimetry protocol. Methods: Nine centers (ten GSRS units) participated in the study. Each institution made eight sets of dose rate measurements: six with two different ionization chambers in three different 160mm-diameter spherical phantoms (ABS plastic, Solid Water and liquid water), and two using the same ionization chambers with a custom in-air positioning jig. Absolute dose rates were calculated using a newly proposed formalismmore » by the IAEA working group for small and non-standard radiation fields and with a new air-kerma based protocol. The new IAEA protocol requires an in-water ionization chamber calibration and uses previously reported Monte-Carlo generated factors to account for the material composition of the phantom, the type of ionization chamber, and the unique GSRS beam configuration. Results obtained with the new dose calibration protocols were compared to dose rates determined by the AAPM TG-21 and TG-51 protocols, with TG-21 considered as the standard. Results: Averaged over all institutions, ionization chambers and phantoms, the mean dose rate determined with the new IAEA protocol relative to that determined with TG-21 in the ABS phantom was 1.000 with a standard deviation of 0.008. For TG-51, the average ratio was 0.991 with a standard deviation of 0.013, and for the new in-air formalism it was 1.008 with a standard deviation of 0.012. Conclusion: Average results with both of the new protocols agreed with TG-21 to within one standard deviation. TG-51, which does not take into account the unique GSRS beam configuration or phantom material, was not expected to perform as well as the new protocols. The new IAEA protocol showed remarkably good agreement with TG-21. Conflict of Interests: Paula Petti, Josef Novotny, Gennady Neyman and Steve Goetsch are consultants for Elekta Instrument A/B; Elekta Instrument AB, PTW Freiburg GmbH, Standard Imaging, Inc., and The Phantom Laboratory, Inc. loaned equipment for use in these experiments; The University of Wisconsin Accredited Dosimetry Calibration Laboratory provided calibration services.« less
NASA Astrophysics Data System (ADS)
Lahmiri, Salim
2016-02-01
Multiresolution analysis techniques including continuous wavelet transform, empirical mode decomposition, and variational mode decomposition are tested in the context of interest rate next-day variation prediction. In particular, multiresolution analysis techniques are used to decompose interest rate actual variation and feedforward neural network for training and prediction. Particle swarm optimization technique is adopted to optimize its initial weights. For comparison purpose, autoregressive moving average model, random walk process and the naive model are used as main reference models. In order to show the feasibility of the presented hybrid models that combine multiresolution analysis techniques and feedforward neural network optimized by particle swarm optimization, we used a set of six illustrative interest rates; including Moody's seasoned Aaa corporate bond yield, Moody's seasoned Baa corporate bond yield, 3-Month, 6-Month and 1-Year treasury bills, and effective federal fund rate. The forecasting results show that all multiresolution-based prediction systems outperform the conventional reference models on the criteria of mean absolute error, mean absolute deviation, and root mean-squared error. Therefore, it is advantageous to adopt hybrid multiresolution techniques and soft computing models to forecast interest rate daily variations as they provide good forecasting performance.
Multiple regression technique for Pth degree polynominals with and without linear cross products
NASA Technical Reports Server (NTRS)
Davis, J. W.
1973-01-01
A multiple regression technique was developed by which the nonlinear behavior of specified independent variables can be related to a given dependent variable. The polynomial expression can be of Pth degree and can incorporate N independent variables. Two cases are treated such that mathematical models can be studied both with and without linear cross products. The resulting surface fits can be used to summarize trends for a given phenomenon and provide a mathematical relationship for subsequent analysis. To implement this technique, separate computer programs were developed for the case without linear cross products and for the case incorporating such cross products which evaluate the various constants in the model regression equation. In addition, the significance of the estimated regression equation is considered and the standard deviation, the F statistic, the maximum absolute percent error, and the average of the absolute values of the percent of error evaluated. The computer programs and their manner of utilization are described. Sample problems are included to illustrate the use and capability of the technique which show the output formats and typical plots comparing computer results to each set of input data.
NASA Astrophysics Data System (ADS)
Zhang, Rui; Yao, Yi-bin; Hu, Yue-ming; Song, Wei-wei
2017-12-01
The Global Navigation Satellite System presents a plausible and cost-effective way of computing the total electron content (TEC). But TEC estimated value could be seriously affected by the differential code biases (DCB) of frequency-dependent satellites and receivers. Unlike GPS and other satellite systems, GLONASS adopts a frequency-division multiplexing access mode to distinguish different satellites. This strategy leads to different wavelengths and inter-frequency biases (IFBs) for both pseudo-range and carrier phase observations, whose impacts are rarely considered in ionospheric modeling. We obtained observations from four groups of co-stations to analyze the characteristics of the GLONASS receiver P1P2 pseudo-range IFB with a double-difference method. The results showed that the GLONASS P1P2 pseudo-range IFB remained stable for a period of time and could catch up to several meters, which cannot be absorbed by the receiver DCB during ionospheric modeling. Given the characteristics of the GLONASS P1P2 pseudo-range IFB, we proposed a two-step ionosphere modeling method with the priori IFB information. The experimental analysis showed that the new algorithm can effectively eliminate the adverse effects on ionospheric model and hardware delay parameters estimation in different space environments. During high solar activity period, compared to the traditional GPS + GLONASS modeling algorithm, the absolute average deviation of TEC decreased from 2.17 to 2.07 TECu (TEC unit); simultaneously, the average RMS of GPS satellite DCB decreased from 0.225 to 0.219 ns, and the average deviation of GLONASS satellite DCB decreased from 0.253 to 0.113 ns with a great improvement in over 55%.
Calibrated Color and Albedo Maps of Mercury
NASA Astrophysics Data System (ADS)
Robinson, M. S.; Lucey, P. G.
1996-03-01
In order to determine the albedo and color of the mercurian surface, we are completing calibrated mosaics of Mariner 10 image data. A set of clear filter mosaics is being compiled in such a way as to maximize the signal-to-noise-ratio of the data and to allow for a quantitative measure of the precision of the data on a pixel-by-pixel basis. Three major imaging sequences of Mercury were acquired by Mariner 10: incoming first encounter (centered at 20S, 2E), outgoing first encounter (centered at 20N, 175E), and southern hemisphere second encounter (centered at 40S, 100E). For each sequence we are making separate mosaics for each camera (A and B) in order to have independent measurements. For each mosaic, regions of overlap from frame-to-frame are being averaged and the attendant standard deviations are being calculated. Due to the highly redundant nature of the data, each pixel in each mosaic will be an average calculated from 1-10 images. Each mosaic will have a corresponding standard deviation and n (number of measurements) map. A final mosaic will be created by averaging the six independent mosaics. This procedure lessens the effects of random noise and calibration residuals. From these data an albedo map will be produced using an improved photometric function for the Moon. A similar procedure is being followed for the lower resolution color sequences (ultraviolet, blue, orange, ultraviolet polarized). These data will be calibrated to absolute units through comparison of Mariner 10 images acquired of the Moon and Jupiter. Spectral interpretation of these new color and albedo maps will be presented with an emphasis on comparison with the Moon.
ESTIMATION OF EFFECTIVE SHEAR STRESS WORKING ON FLAT SHEET MEMBRANE USING FLUIDIZED MEDIA IN MBRs
NASA Astrophysics Data System (ADS)
Zaw, Hlwan Moe; Li, Tairi; Nagaoka, Hiroshi; Mishima, Iori
This study was aimed at estimating effective shear stress working on flat sheet membrane by the addition of fluidized media in MBRs. In both of laboratory-scale aeration tanks with and without fluidized media, shear stress variations on membrane surface and water phase velocity variations were measured and MBR operation was conducted. For the evaluation of the effective shear stress working on membrane surface to mitigate membrane surface, simulation of trans-membrane pressure increase was conducted. It was shown that the time-averaged absolute value of shear stress was smaller in the reactor with fluidized media than without fluidized media. However, due to strong turbulence in the reactor with fluidized media caused by interaction between water-phase and media and also due to the direct interaction between membrane surface and fluidized media, standard deviation of shear stress on membrane surface was larger in the reactor with fluidized media than without media. Histograms of shear stress variation data were fitted well to normal distribution curves and mean plus three times of standard deviation was defined to be a maximum shear stress value. By applying the defined maximum shear stress to a membrane fouling model, trans-membrane pressure curve in the MBR experiment was simulated well by the fouling model indicting that the maximum shear stress, not time-averaged shear stress, can be regarded as an effective shear stress to prevent membrane fouling in submerged flat-sheet MBRs.
NASA Astrophysics Data System (ADS)
Prentice, Boone M.; Chumbley, Chad W.; Caprioli, Richard M.
2017-01-01
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R2) and accuracy (>93% quality controls, <9% relative errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%.
Boonen, Bert; Schotanus, Martijn G M; Kerens, Bart; Hulsmans, Frans-Jan; Tuinebreijer, Wim E; Kort, Nanne P
2017-09-01
To assess whether there is a significant difference between the alignment of the individual femoral and tibial components (in the frontal, sagittal and horizontal planes) as calculated pre-operatively (digital plan) and the actually achieved alignment in vivo obtained with the use of patient-specific positioning guides (PSPGs) for TKA. It was hypothesised that there would be no difference between post-op implant position and pre-op digital plan. Twenty-six patients were included in this non-inferiority trial. Software permitted matching of the pre-operative MRI scan (and therefore calculated prosthesis position) to a pre-operative CT scan and then to a post-operative full-leg CT scan to determine deviations from pre-op planning in all three anatomical planes. For the femoral component, mean absolute deviations from planning were 1.8° (SD 1.3), 2.5° (SD 1.6) and 1.6° (SD 1.4) in the frontal, sagittal and transverse planes, respectively. For the tibial component, mean absolute deviations from planning were 1.7° (SD 1.2), 1.7° (SD 1.5) and 3.2° (SD 3.6) in the frontal, sagittal and transverse planes, respectively. Absolute mean deviation from planned mechanical axis was 1.9°. The a priori specified null hypothesis for equivalence testing: the difference from planning is >3 or <-3 was rejected for all comparisons except for the tibial transverse plane. PSPG was able to adequately reproduce the pre-op plan in all planes, except for the tibial rotation in the transverse plane. Possible explanations for outliers are discussed and highlight the importance for adequate training surgeons before they start using PSPG in their day-by-day practise. Prospective cohort study, Level II.
Multicentre dose audit for clinical trials of radiation therapy in Asia
Fukuda, Shigekazu; Fukumura, Akifumi; Nakamura, Yuzuru-Kutsutani; Jianping, Cao; Cho, Chul-Koo; Supriana, Nana; Dung, To Anh; Calaguas, Miriam Joy; Devi, C.R. Beena; Chansilpa, Yaowalak; Banu, Parvin Akhter; Riaz, Masooma; Esentayeva, Surya; Kato, Shingo; Karasawa, Kumiko; Tsujii, Hirohiko
2017-01-01
Abstract A dose audit of 16 facilities in 11 countries has been performed within the framework of the Forum for Nuclear Cooperation in Asia (FNCA) quality assurance program. The quality of radiation dosimetry varies because of the large variation in radiation therapy among the participating countries. One of the most important aspects of international multicentre clinical trials is uniformity of absolute dose between centres. The National Institute of Radiological Sciences (NIRS) in Japan has conducted a dose audit of participating countries since 2006 by using radiophotoluminescent glass dosimeters (RGDs). RGDs have been successfully applied to a domestic postal dose audit in Japan. The authors used the same audit system to perform a dose audit of the FNCA countries. The average and standard deviation of the relative deviation between the measured and intended dose among 46 beams was 0.4% and 1.5% (k = 1), respectively. This is an excellent level of uniformity for the multicountry data. However, of the 46 beams measured, a single beam exceeded the permitted tolerance level of ±5%. We investigated the cause for this and solved the problem. This event highlights the importance of external audits in radiation therapy. PMID:27864507
Pullman, Rebecca E; Roepke, Stephanie E; Duffy, Jeanne F
2012-06-01
To determine whether an accurate circadian phase assessment could be obtained from saliva samples collected by patients in their home. Twenty-four individuals with a complaint of sleep initiation or sleep maintenance difficulty were studied for two evenings. Each participant received instructions for collecting eight hourly saliva samples in dim light at home. On the following evening they spent 9h in a laboratory room with controlled dim (<20 lux) light where hourly saliva samples were collected. Circadian phase of dim light melatonin onset (DLMO) was determined using both an absolute threshold (3 pg ml(-1)) and a relative threshold (two standard deviations above the mean of three baseline values). Neither threshold method worked well for one participant who was a "low-secretor". In four cases the participants' in-lab melatonin levels rose much earlier or were much higher than their at-home levels, and one participant appeared to take the at home samples out of order. Overall, the at-home and in-lab DLMO values were significantly correlated using both methods, and differed on average by 37 (± 19)min using the absolute threshold and by 54 (± 36)min using the relative threshold. The at-home assessment procedure was able to determine an accurate DLMO using an absolute threshold in 62.5% of the participants. Thus, an at-home procedure for assessing circadian phase could be practical for evaluating patients for circadian rhythm sleep disorders. Copyright © 2012 Elsevier B.V. All rights reserved.
Validation of the CrIS fast physical NH3 retrieval with ground-based FTIR
NASA Astrophysics Data System (ADS)
Dammers, Enrico; Shephard, Mark W.; Palm, Mathias; Cady-Pereira, Karen; Capps, Shannon; Lutsch, Erik; Strong, Kim; Hannigan, James W.; Ortega, Ivan; Toon, Geoffrey C.; Stremme, Wolfgang; Grutter, Michel; Jones, Nicholas; Smale, Dan; Siemons, Jacob; Hrpcek, Kevin; Tremblay, Denis; Schaap, Martijn; Notholt, Justus; Erisman, Jan Willem
2017-07-01
Presented here is the validation of the CrIS (Cross-track Infrared Sounder) fast physical NH3 retrieval (CFPR) column and profile measurements using ground-based Fourier transform infrared (FTIR) observations. We use the total columns and profiles from seven FTIR sites in the Network for the Detection of Atmospheric Composition Change (NDACC) to validate the satellite data products. The overall FTIR and CrIS total columns have a positive correlation of r = 0.77 (N = 218) with very little bias (a slope of 1.02). Binning the comparisons by total column amounts, for concentrations larger than 1.0 × 1016 molecules cm-2, i.e. ranging from moderate to polluted conditions, the relative difference is on average ˜ 0-5 % with a standard deviation of 25-50 %, which is comparable to the estimated retrieval uncertainties in both CrIS and the FTIR. For the smallest total column range (< 1.0 × 1016 molecules cm-2) where there are a large number of observations at or near the CrIS noise level (detection limit) the absolute differences between CrIS and the FTIR total columns show a slight positive column bias. The CrIS and FTIR profile comparison differences are mostly within the range of the single-level retrieved profile values from estimated retrieval uncertainties, showing average differences in the range of ˜ 20 to 40 %. The CrIS retrievals typically show good vertical sensitivity down into the boundary layer which typically peaks at ˜ 850 hPa (˜ 1.5 km). At this level the median absolute difference is 0.87 (std = ±0.08) ppb, corresponding to a median relative difference of 39 % (std = ±2 %). Most of the absolute and relative profile comparison differences are in the range of the estimated retrieval uncertainties. At the surface, where CrIS typically has lower sensitivity, it tends to overestimate in low-concentration conditions and underestimate in higher atmospheric concentration conditions.
NASA Astrophysics Data System (ADS)
Maggio, Angelo; Carillo, Viviana; Cozzarini, Cesare; Perna, Lucia; Rancati, Tiziana; Valdagni, Riccardo; Gabriele, Pietro; Fiorino, Claudio
2013-04-01
The aim of this study was to evaluate the correlation between the ‘true’ absolute and relative dose-volume histograms (DVHs) of the bladder wall, dose-wall histogram (DWH) defined on MRI imaging and other surrogates of bladder dosimetry in prostate cancer patients, planned both with 3D-conformal and intensity-modulated radiation therapy (IMRT) techniques. For 17 prostate cancer patients, previously treated with radical intent, CT and MRI scans were acquired and matched. The contours of bladder walls were drawn by using MRI images. External bladder surfaces were then used to generate artificial bladder walls by performing automatic contractions of 5, 7 and 10 mm. For each patient a 3D conformal radiotherapy (3DCRT) and an IMRT treatment plan was generated with a prescription dose of 77.4 Gy (1.8 Gy/fr) and DVH of the whole bladder of the artificial walls (DVH-5/10) and dose-surface histograms (DSHs) were calculated and compared against the DWH in absolute and relative value, for both treatment planning techniques. A specific software (VODCA v. 4.4.0, MSS Inc.) was used for calculating the dose-volume/surface histogram. Correlation was quantified for selected dose-volume/surface parameters by the Spearman correlation coefficient. The agreement between %DWH and DVH5, DVH7 and DVH10 was found to be very good (maximum average deviations below 2%, SD < 5%): DVH5 showed the best agreement. The correlation was slightly better for absolute (R = 0.80-0.94) compared to relative (R = 0.66-0.92) histograms. The DSH was also found to be highly correlated with the DWH, although slightly higher deviations were generally found. The DVH was not a good surrogate of the DWH (R < 0.7 for most of parameters). When comparing the two treatment techniques, more pronounced differences between relative histograms were seen for IMRT with respect to 3DCRT (p < 0.0001).
Chaste, Pauline; Klei, Lambertus; Sanders, Stephan J; Murtha, Michael T; Hus, Vanessa; Lowe, Jennifer K; Willsey, A Jeremy; Moreno-De-Luca, Daniel; Yu, Timothy W; Fombonne, Eric; Geschwind, Daniel; Grice, Dorothy E; Ledbetter, David H; Lord, Catherine; Mane, Shrikant M; Lese Martin, Christa; Martin, Donna M; Morrow, Eric M; Walsh, Christopher A; Sutcliffe, James S; State, Matthew W; Devlin, Bernie; Cook, Edwin H; Kim, Soo-Jeong
2013-10-15
Brain development follows a different trajectory in children with autism spectrum disorders (ASD) than in typically developing children. A proxy for neurodevelopment could be head circumference (HC), but studies assessing HC and its clinical correlates in ASD have been inconsistent. This study investigates HC and clinical correlates in the Simons Simplex Collection cohort. We used a mixed linear model to estimate effects of covariates and the deviation from the expected HC given parental HC (genetic deviation). After excluding individuals with incomplete data, 7225 individuals in 1891 families remained for analysis. We examined the relationship between HC/genetic deviation of HC and clinical parameters. Gender, age, height, weight, genetic ancestry, and ASD status were significant predictors of HC (estimate of the ASD effect = .2 cm). HC was approximately normally distributed in probands and unaffected relatives, with only a few outliers. Genetic deviation of HC was also normally distributed, consistent with a random sampling of parental genes. Whereas larger HC than expected was associated with ASD symptom severity and regression, IQ decreased with the absolute value of the genetic deviation of HC. Measured against expected values derived from covariates of ASD subjects, statistical outliers for HC were uncommon. HC is a strongly heritable trait, and population norms for HC would be far more accurate if covariates including genetic ancestry, height, and age were taken into account. The association of diminishing IQ with absolute deviation from predicted HC values suggests HC could reflect subtle underlying brain development and warrants further investigation. © 2013 Society of Biological Psychiatry.
Chaste, Pauline; Klei, Lambertus; Sanders, Stephan J.; Murtha, Michael T.; Hus, Vanessa; Lowe, Jennifer K.; Willsey, A. Jeremy; Moreno-De-Luca, Daniel; Yu, Timothy W.; Fombonne, Eric; Geschwind, Daniel; Grice, Dorothy E.; Ledbetter, David H.; Lord, Catherine; Mane, Shrikant M.; Martin, Christa Lese; Martin, Donna M.; Morrow, Eric M.; Walsh, Christopher A.; Sutcliffe, James S.; State, Matthew W.; Devlin, Bernie; Cook, Edwin H.; Kim, Soo-Jeong
2013-01-01
BACKGROUND Brain development follows a different trajectory in children with Autism Spectrum Disorders (ASD) than in typically developing children. A proxy for neurodevelopment could be head circumference (HC), but studies assessing HC and its clinical correlates in ASD have been inconsistent. This study investigates HC and clinical correlates in the Simons Simplex Collection cohort. METHODS We used a mixed linear model to estimate effects of covariates and the deviation from the expected HC given parental HC (genetic deviation). After excluding individuals with incomplete data, 7225 individuals in 1891 families remained for analysis. We examined the relationship between HC/genetic deviation of HC and clinical parameters. RESULTS Gender, age, height, weight, genetic ancestry and ASD status were significant predictors of HC (estimate of the ASD effect=0.2cm). HC was approximately normally distributed in probands and unaffected relatives, with only a few outliers. Genetic deviation of HC was also normally distributed, consistent with a random sampling of parental genes. Whereas larger HC than expected was associated with ASD symptom severity and regression, IQ decreased with the absolute value of the genetic deviation of HC. CONCLUSIONS Measured against expected values derived from covariates of ASD subjects, statistical outliers for HC were uncommon. HC is a strongly heritable trait and population norms for HC would be far more accurate if covariates including genetic ancestry, height and age were taken into account. The association of diminishing IQ with absolute deviation from predicted HC values suggests HC could reflect subtle underlying brain development and warrants further investigation. PMID:23746936
Alghanim, Hussain; Antunes, Joana; Silva, Deborah Soares Bispo Santos; Alho, Clarice Sampaio; Balamurugan, Kuppareddi; McCord, Bruce
2017-11-01
Recent developments in the analysis of epigenetic DNA methylation patterns have demonstrated that certain genetic loci show a linear correlation with chronological age. It is the goal of this study to identify a new set of epigenetic methylation markers for the forensic estimation of human age. A total number of 27 CpG sites at three genetic loci, SCGN, DLX5 and KLF14, were examined to evaluate the correlation of their methylation status with age. These sites were evaluated using 72 blood samples and 91 saliva samples collected from volunteers with ages ranging from 5 to 73 years. DNA was bisulfite modified followed by PCR amplification and pyrosequencing to determine the level of DNA methylation at each CpG site. In this study, certain CpG sites in SCGN and KLF14 loci showed methylation levels that were correlated with chronological age, however, the tested CpG sites in DLX5 did not show a correlation with age. Using a 52-saliva sample training set, two age-predictor models were developed by means of a multivariate linear regression analysis for age prediction. The two models performed similarly with a single-locus model explaining 85% of the age variance at a mean absolute deviation of 5.8 years and a dual-locus model explaining 84% of the age variance with a mean absolute deviation of 6.2 years. In the validation set, the mean absolute deviation was measured to be 8.0 years and 7.1 years for the single- and dual-locus model, respectively. Another age predictor model was also developed using a 40-blood sample training set that accounted for 71% of the age variance. This model gave a mean absolute deviation of 6.6 years for the training set and 10.3years for the validation set. The results indicate that specific CpGs in SCGN and KLF14 can be used as potential epigenetic markers to estimate age using saliva and blood specimens. These epigenetic markers could provide important information in cases where the determination of a suspect's age is critical in developing investigative leads. Copyright © 2017. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Scalabrin, G.; Marchi, P.; Finezzo, F.
2006-11-01
The application of an optimization technique to the available experimental data has led to the development of a new multiparameter equation λ = λ ( T,ρ ) for the representation of the thermal conductivity of 1,1-difluoroethane (R152a). The region of validity of the proposed equation covers the temperature range from 220 to 460 K and pressures up to 55 MPa, including the near-critical region. The average absolute deviation of the equation with respect to the selected 939 primary data points is 1.32%. The proposed equation represents therefore a significant improvement with respect to the literature conventional equation. The density value required by the equation is calculated at the chosen temperature and pressure conditions using a high accuracy equation of state for the fluid.
Review of the BACKONE equation of state and its applications
NASA Astrophysics Data System (ADS)
Lai, Ngoc Anh; Phan, Thi Thu Huong
2017-06-01
This paper presents a review of the BACKONE equation of state (EOS) and its various applications in the study of pure fluid and mixtures as refrigerants, working fluids, natural gases and the study of heat pumps, refrigeration cycles, organic Rankine cycles, trilateral cycles and power flash cycles. It also presents an accurate parameterisation of the BACKONE EOS for the low global warming potential working fluid 3,3,3-trifluoropropene (HFO-1243zf). The average absolute deviations (AAD) between experimental vapour pressure and saturated liquid density data from those of the BACKONE EOS are 0.12% and 0.08%, respectively. The BACKONE EOS for HFO-1243zf also predicts thermodynamic data accurately. The AAD between the BACKONE predicted values and experimental data are 0.20% for sub-cooled liquid density and 0.56% for gaseous pressure.
NASA Astrophysics Data System (ADS)
Tian, Jianxiang; Zhang, Cuihua; Zhang, Laibin; Zheng, Mengmeng; Liu, Shuzhen
2017-10-01
Based on the recent progresses on the corresponding state-based correlations for the temperature-dependent surface tension of saturated fluids [I. Cachadiña, A. Mulero and J. X. Tian, Fluid Phase Equilibr. 442 (2017) 68; J. X. Tian, M. M. Zheng, H. L. Yi, L. B. Zhang and S. Z. Liu, Mod. Phys. Lett. B 31 (2017) 1750110], we proposed a new correlation for saturated hydrocarbons. This correlation includes three fluid-independent parameters and inquires the critical temperature, the triple-point temperature and the surface tension at the triple-point temperature as inputs for each hydrocarbon. Results show that this correlation can reproduce NIST data with absolute average deviation (AAD) less than 1% for 10 out of 19 hydrocarbons and AAD less than 5% for 17 out of 19 hydrocarbons, clearly better than other correlations.
A critical assessment of two types of personal UV dosimeters.
Seckmeyer, Gunther; Klingebiel, Marcus; Riechelmann, Stefan; Lohse, Insa; McKenzie, Richard L; Liley, J Ben; Allen, Martin W; Siani, Anna-Maria; Casale, Giuseppe R
2012-01-01
Doses of erythemally weighted irradiances derived from polysulphone (PS) and electronic ultraviolet (EUV) dosimeters have been compared with measurements obtained using a reference spectroradiometer. PS dosimeters showed mean absolute deviations of 26% with a maximum deviation of 44%, the calibrated EUV dosimeters showed mean absolute deviations of 15% (maximum 33%) around noon during several test days in the northern hemisphere autumn. In the case of EUV dosimeters, measurements with various cut-off filters showed that part of the deviation from the CIE erythema action spectrum was due to a small, but significant sensitivity to visible radiation that varies between devices and which may be avoided by careful preselection. Usually the method of calibrating UV sensors by direct comparison to a reference instrument leads to reliable results. However, in some circumstances the quality of measurements made with simple sensors may be over-estimated. In the extreme case, a simple pyranometer can be used as a UV instrument, providing acceptable results for cloudless skies, but very poor results under cloudy conditions. It is concluded that while UV dosimeters are useful for their design purpose, namely to estimate personal UV exposures, they should not be regarded as an inexpensive replacement for meteorological grade instruments. © 2011 Wiley Periodicals, Inc. Photochemistry and Photobiology © 2011 The American Society of Photobiology.
Bolann, B J; Asberg, A
2004-01-01
The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.
NASA Astrophysics Data System (ADS)
Nooruddin, Hasan A.; Anifowose, Fatai; Abdulraheem, Abdulazeez
2014-03-01
Soft computing techniques are recently becoming very popular in the oil industry. A number of computational intelligence-based predictive methods have been widely applied in the industry with high prediction capabilities. Some of the popular methods include feed-forward neural networks, radial basis function network, generalized regression neural network, functional networks, support vector regression and adaptive network fuzzy inference system. A comparative study among most popular soft computing techniques is presented using a large dataset published in literature describing multimodal pore systems in the Arab D formation. The inputs to the models are air porosity, grain density, and Thomeer parameters obtained using mercury injection capillary pressure profiles. Corrected air permeability is the target variable. Applying developed permeability models in recent reservoir characterization workflow ensures consistency between micro and macro scale information represented mainly by Thomeer parameters and absolute permeability. The dataset was divided into two parts with 80% of data used for training and 20% for testing. The target permeability variable was transformed to the logarithmic scale as a pre-processing step and to show better correlations with the input variables. Statistical and graphical analysis of the results including permeability cross-plots and detailed error measures were created. In general, the comparative study showed very close results among the developed models. The feed-forward neural network permeability model showed the lowest average relative error, average absolute relative error, standard deviations of error and root means squares making it the best model for such problems. Adaptive network fuzzy inference system also showed very good results.
In Vivo Measurement of Pediatric Vocal Fold Motion Using Structured Light Laser Projection
Patel, Rita R.; Donohue, Kevin D.; Lau, Daniel; Unnikrishnan, Harikrishnan
2013-01-01
Summary Objective The aim of the study was to present the development of a miniature structured light laser projection endoscope and to quantify vocal fold length and vibratory features related to impact stress of the pediatric glottis using high-speed imaging. Study Design The custom-developed laser projection system consists of a green laser with a 4-mm diameter optics module at the tip of the endoscope, projecting 20 vertical laser lines on the glottis. Measurements of absolute phonatory vocal fold length, membranous vocal fold length, peak amplitude, amplitude-to-length ratio, average closing velocity, and impact velocity were obtained in five children (6–9 years), two adult male and three adult female participants without voice disorders, and one child (10 years) with bilateral vocal fold nodules during modal phonation. Results Independent measurements made on the glottal length of a vocal fold phantom demonstrated a 0.13 mm bias error with a standard deviation of 0.23 mm, indicating adequate precision and accuracy for measuring vocal fold structures and displacement. First, in vivo measurements of amplitude-to-length ratio, peak closing velocity, and impact velocity during phonation in pediatric population and a child with vocal fold nodules are reported. Conclusion The proposed laser projection system can be used to obtain in vivo measurements of absolute length and vibratory features in children and adults. Children have large amplitude-to-length ratio compared with typically developing adults, whereas nodules result in larger peak amplitude, amplitude-to-length ratio, average closing velocity, and impact velocity compared with typically developing children. PMID:23809569
Belief Propagation Algorithm for Portfolio Optimization Problems
2015-01-01
The typical behavior of optimal solutions to portfolio optimization problems with absolute deviation and expected shortfall models using replica analysis was pioneeringly estimated by S. Ciliberti et al. [Eur. Phys. B. 57, 175 (2007)]; however, they have not yet developed an approximate derivation method for finding the optimal portfolio with respect to a given return set. In this study, an approximation algorithm based on belief propagation for the portfolio optimization problem is presented using the Bethe free energy formalism, and the consistency of the numerical experimental results of the proposed algorithm with those of replica analysis is confirmed. Furthermore, the conjecture of H. Konno and H. Yamazaki, that the optimal solutions with the absolute deviation model and with the mean-variance model have the same typical behavior, is verified using replica analysis and the belief propagation algorithm. PMID:26305462
Belief Propagation Algorithm for Portfolio Optimization Problems.
Shinzato, Takashi; Yasuda, Muneki
2015-01-01
The typical behavior of optimal solutions to portfolio optimization problems with absolute deviation and expected shortfall models using replica analysis was pioneeringly estimated by S. Ciliberti et al. [Eur. Phys. B. 57, 175 (2007)]; however, they have not yet developed an approximate derivation method for finding the optimal portfolio with respect to a given return set. In this study, an approximation algorithm based on belief propagation for the portfolio optimization problem is presented using the Bethe free energy formalism, and the consistency of the numerical experimental results of the proposed algorithm with those of replica analysis is confirmed. Furthermore, the conjecture of H. Konno and H. Yamazaki, that the optimal solutions with the absolute deviation model and with the mean-variance model have the same typical behavior, is verified using replica analysis and the belief propagation algorithm.
Fuzzy Random λ-Mean SAD Portfolio Selection Problem: An Ant Colony Optimization Approach
NASA Astrophysics Data System (ADS)
Thakur, Gour Sundar Mitra; Bhattacharyya, Rupak; Mitra, Swapan Kumar
2010-10-01
To reach the investment goal, one has to select a combination of securities among different portfolios containing large number of securities. Only the past records of each security do not guarantee the future return. As there are many uncertain factors which directly or indirectly influence the stock market and there are also some newer stock markets which do not have enough historical data, experts' expectation and experience must be combined with the past records to generate an effective portfolio selection model. In this paper the return of security is assumed to be Fuzzy Random Variable Set (FRVS), where returns are set of random numbers which are in turn fuzzy numbers. A new λ-Mean Semi Absolute Deviation (λ-MSAD) portfolio selection model is developed. The subjective opinions of the investors to the rate of returns of each security are taken into consideration by introducing a pessimistic-optimistic parameter vector λ. λ-Mean Semi Absolute Deviation (λ-MSAD) model is preferred as it follows absolute deviation of the rate of returns of a portfolio instead of the variance as the measure of the risk. As this model can be reduced to Linear Programming Problem (LPP) it can be solved much faster than quadratic programming problems. Ant Colony Optimization (ACO) is used for solving the portfolio selection problem. ACO is a paradigm for designing meta-heuristic algorithms for combinatorial optimization problem. Data from BSE is used for illustration.
NASA Astrophysics Data System (ADS)
Karaali, S.; Gökçe, E. Yaz; Bilir, S.; Güçtekin, S. Tunçel
2014-07-01
We present two absolute magnitude calibrations for dwarfs based on colour-magnitude diagrams of Galactic clusters. The combination of the Mg absolute magnitudes of the dwarf fiducial sequences of the clusters M92, M13, M5, NGC 2420, M67, and NGC 6791 with the corresponding metallicities provides absolute magnitude calibration for a given (g - r)0 colour. The calibration is defined in the colour interval 0.25 ≤ (g - r)0 ≤ 1.25 mag and it covers the metallicity interval - 2.15 ≤ [Fe/H] ≤ +0.37 dex. The absolute magnitude residuals obtained by the application of the procedure to another set of Galactic clusters lie in the interval - 0.15 ≤ ΔMg ≤ +0.12 mag. The mean and standard deviation of the residuals are < ΔMg > = - 0.002 and σ = 0.065 mag, respectively. The calibration of the MJ absolute magnitude in terms of metallicity is carried out by using the fiducial sequences of the clusters M92, M13, 47 Tuc, NGC 2158, and NGC 6791. It is defined in the colour interval 0.90 ≤ (V - J)0 ≤ 1.75 mag and it covers the same metallicity interval of the Mg calibration. The absolute magnitude residuals obtained by the application of the procedure to the cluster M5 ([Fe/H] = -1.40 dex) and 46 solar metallicity, - 0.45 ≤ [Fe/H] ≤ +0.35 dex, field stars lie in the interval - 0.29 and + 0.35 mag. However, the range of 87% of them is rather shorter, - 0.20 ≤ ΔMJ ≤ +0.20 mag. The mean and standard deviation of all residuals are < ΔMJ > =0.05 and σ = 0.13 mag, respectively. The derived relations are applicable to stars older than 4 Gyr for the Mg calibration, and older than 2 Gyr for the MJ calibration. The cited limits are the ages of the youngest calibration clusters in the two systems.
Electronic Absolute Cartesian Autocollimator
NASA Technical Reports Server (NTRS)
Leviton, Douglas B.
2006-01-01
An electronic absolute Cartesian autocollimator performs the same basic optical function as does a conventional all-optical or a conventional electronic autocollimator but differs in the nature of its optical target and the manner in which the position of the image of the target is measured. The term absolute in the name of this apparatus reflects the nature of the position measurement, which, unlike in a conventional electronic autocollimator, is based absolutely on the position of the image rather than on an assumed proportionality between the position and the levels of processed analog electronic signals. The term Cartesian in the name of this apparatus reflects the nature of its optical target. Figure 1 depicts the electronic functional blocks of an electronic absolute Cartesian autocollimator along with its basic optical layout, which is the same as that of a conventional autocollimator. Referring first to the optical layout and functions only, this or any autocollimator is used to measure the compound angular deviation of a flat datum mirror with respect to the optical axis of the autocollimator itself. The optical components include an illuminated target, a beam splitter, an objective or collimating lens, and a viewer or detector (described in more detail below) at a viewing plane. The target and the viewing planes are focal planes of the lens. Target light reflected by the datum mirror is imaged on the viewing plane at unit magnification by the collimating lens. If the normal to the datum mirror is parallel to the optical axis of the autocollimator, then the target image is centered on the viewing plane. Any angular deviation of the normal from the optical axis manifests itself as a lateral displacement of the target image from the center. The magnitude of the displacement is proportional to the focal length and to the magnitude (assumed to be small) of the angular deviation. The direction of the displacement is perpendicular to the axis about which the mirror is slightly tilted. Hence, one can determine the amount and direction of tilt from the coordinates of the target image on the viewing plane.
Resting-State Oscillatory Activity in Children Born Small for Gestational Age: An MEG Study
Boersma, Maria; de Bie, Henrica M. A.; Oostrom, Kim J.; van Dijk, Bob W.; Hillebrand, Arjan; van Wijk, Bernadette C. M.; Delemarre-van de Waal, Henriëtte A.; Stam, Cornelis J.
2013-01-01
Growth restriction in utero during a period that is critical for normal growth of the brain, has previously been associated with deviations in cognitive abilities and brain anatomical and functional changes. We measured magnetoencephalography (MEG) in 4- to 7-year-old children to test if children born small for gestational age (SGA) show deviations in resting-state brain oscillatory activity. Children born SGA with postnatally spontaneous catch-up growth [SGA+; six boys, seven girls; mean age 6.3 year (SD = 0.9)] and children born appropriate for gestational age [AGA; seven boys, three girls; mean age 6.0 year (SD = 1.2)] participated in a resting-state MEG study. We calculated absolute and relative power spectra and used non-parametric statistics to test for group differences. SGA+ and AGA born children showed no significant differences in absolute and relative power except for reduced absolute gamma band power in SGA children. At the time of MEG investigation, SGA+ children showed significantly lower head circumference (HC) and a trend toward lower IQ, however there was no association of HC or IQ with absolute or relative power. Except for reduced absolute gamma band power, our findings suggest normal brain activity patterns at school age in a group of children born SGA in which spontaneous catch-up growth of bodily length after birth occurred. Although previous findings suggest that being born SGA alters brain oscillatory activity early in neonatal life, we show that these neonatal alterations do not persist at early school age when spontaneous postnatal catch-up growth occurs after birth. PMID:24068993
Estimating the Kinematic Viscosity of Petroleum Fractions
NASA Astrophysics Data System (ADS)
AlMulla, Hessa A.; Albahri, Tareq A.
2017-04-01
Kinematic viscosity correlation has been developed for liquid petroleum fractions at 37.78°C and 98.89°C (100 and 210°F) standard temperatures using a large variety of experimental data. The only required inputs are the specific gravity and the average boiling point temperature. The accuracy of the correlation was compared with several other correlations available in the literature. The proposed correlations proved to be more accurate in predicting the viscosity at 37.78°C and 98.89°C with average absolute deviations of 0.39 and 0.72 mm2/s, respectively. Another objective was to develop a relation for the variation of viscosity with temperature to predict the viscosity of petroleum fraction at a certain temperature from the knowledge of the viscosity for the same liquid at two other temperatures. The newly developed correlation represents a wide array of temperatures from 20°C to 150°C and viscosities from 0.14 mm2/s to 343.64 mm2/s. The results have been validated with experimental data consisting of 9558 data points, yielding an overall deviation of 0.248 mm2/s and R2 of 0.998. In addition, new formulas were developed to interconvert the viscosity of petroleum fractions from one unit of measure to another based on finding the best fit for a set of experimental data from the literature with R2 as high as 1.0 for many cases. Detailed analysis showed good agreement between the predicted values and the experimental data.
Arima model and exponential smoothing method: A comparison
NASA Astrophysics Data System (ADS)
Wan Ahmad, Wan Kamarul Ariffin; Ahmad, Sabri
2013-04-01
This study shows the comparison between Autoregressive Moving Average (ARIMA) model and Exponential Smoothing Method in making a prediction. The comparison is focused on the ability of both methods in making the forecasts with the different number of data sources and the different length of forecasting period. For this purpose, the data from The Price of Crude Palm Oil (RM/tonne), Exchange Rates of Ringgit Malaysia (RM) in comparison to Great Britain Pound (GBP) and also The Price of SMR 20 Rubber Type (cents/kg) with three different time series are used in the comparison process. Then, forecasting accuracy of each model is measured by examinethe prediction error that producedby using Mean Squared Error (MSE), Mean Absolute Percentage Error (MAPE), and Mean Absolute deviation (MAD). The study shows that the ARIMA model can produce a better prediction for the long-term forecasting with limited data sources, butcannot produce a better prediction for time series with a narrow range of one point to another as in the time series for Exchange Rates. On the contrary, Exponential Smoothing Method can produce a better forecasting for Exchange Rates that has a narrow range of one point to another for its time series, while itcannot produce a better prediction for a longer forecasting period.
Zhang, Kai; Li, Yun; Schwartz, Joel D.; O'Neill, Marie S.
2014-01-01
Hot weather increases risk of mortality. Previous studies used different sets of weather variables to characterize heat stress, resulting in variation in heat-mortality- associations depending on the metric used. We employed a statistical learning method – random forests – to examine which of various weather variables had the greatest impact on heat-related mortality. We compiled a summertime daily weather and mortality counts dataset from four U.S. cities (Chicago, IL; Detroit, MI; Philadelphia, PA; and Phoenix, AZ) from 1998 to 2006. A variety of weather variables were ranked in predicting deviation from typical daily all-cause and cause-specific death counts. Ranks of weather variables varied with city and health outcome. Apparent temperature appeared to be the most important predictor of heat-related mortality for all-cause mortality. Absolute humidity was, on average, most frequently selected one of the top variables for all-cause mortality and seven cause-specific mortality categories. Our analysis affirms that apparent temperature is a reasonable variable for activating heat alerts and warnings, which are commonly based on predictions of total mortality in next few days. Additionally, absolute humidity should be included in future heat-health studies. Finally, random forests can be used to guide choice of weather variables in heat epidemiology studies. PMID:24834832
A suggestion for computing objective function in model calibration
Wu, Yiping; Liu, Shuguang
2014-01-01
A parameter-optimization process (model calibration) is usually required for numerical model applications, which involves the use of an objective function to determine the model cost (model-data errors). The sum of square errors (SSR) has been widely adopted as the objective function in various optimization procedures. However, ‘square error’ calculation was found to be more sensitive to extreme or high values. Thus, we proposed that the sum of absolute errors (SAR) may be a better option than SSR for model calibration. To test this hypothesis, we used two case studies—a hydrological model calibration and a biogeochemical model calibration—to investigate the behavior of a group of potential objective functions: SSR, SAR, sum of squared relative deviation (SSRD), and sum of absolute relative deviation (SARD). Mathematical evaluation of model performance demonstrates that ‘absolute error’ (SAR and SARD) are superior to ‘square error’ (SSR and SSRD) in calculating objective function for model calibration, and SAR behaved the best (with the least error and highest efficiency). This study suggests that SSR might be overly used in real applications, and SAR may be a reasonable choice in common optimization implementations without emphasizing either high or low values (e.g., modeling for supporting resources management).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thakkar, Ajit J., E-mail: ajit@unb.ca; Wu, Taozhe
2015-10-14
Static electronic dipole polarizabilities for 135 molecules are calculated using second-order Møller-Plesset perturbation theory and six density functionals recently recommended for polarizabilities. Comparison is made with the best gas-phase experimental data. The lowest mean absolute percent deviations from the best experimental values for all 135 molecules are 3.03% and 3.08% for the LC-τHCTH and M11 functionals, respectively. Excluding the eight extreme outliers for which the experimental values are almost certainly in error, the mean absolute percent deviation for the remaining 127 molecules drops to 2.42% and 2.48% for the LC-τHCTH and M11 functionals, respectively. Detailed comparison enables us to identifymore » 32 molecules for which the discrepancy between the calculated and experimental values warrants further investigation.« less
A comparison of portfolio selection models via application on ISE 100 index data
NASA Astrophysics Data System (ADS)
Altun, Emrah; Tatlidil, Hüseyin
2013-10-01
Markowitz Model, a classical approach to portfolio optimization problem, relies on two important assumptions: the expected return is multivariate normally distributed and the investor is risk averter. But this model has not been extensively used in finance. Empirical results show that it is very hard to solve large scale portfolio optimization problems with Mean-Variance (M-V)model. Alternative model, Mean Absolute Deviation (MAD) model which is proposed by Konno and Yamazaki [7] has been used to remove most of difficulties of Markowitz Mean-Variance model. MAD model don't need to assume that the probability of the rates of return is normally distributed and based on Linear Programming. Another alternative portfolio model is Mean-Lower Semi Absolute Deviation (M-LSAD), which is proposed by Speranza [3]. We will compare these models to determine which model gives more appropriate solution to investors.
New generalized corresponding states correlation for surface tension of normal saturated liquids
NASA Astrophysics Data System (ADS)
Yi, Huili; Tian, Jianxiang
2015-08-01
A new simple correlation based on the principle of corresponding state is proposed to estimate the temperature-dependent surface tension of normal saturated liquids. The new correlation contains three coefficients obtained by fitting 17,051 surface tension data of 38 saturated normal liquids. These 38 liquids contain refrigerants, hydrocarbons and some other inorganic liquids. The new correlation requires only the triple point temperature, triple point surface tension and critical point temperature as input and is able to well represent the experimental surface tension data for each of the 38 saturated normal liquids from the triple temperature up to the point near the critical point. The new correlation gives absolute average deviations (AAD) values below 3% for all of these 38 liquids with the only exception being octane with AAD=4.30%. Thus, the new correlation gives better overall results in comparison with other correlations for these 38 normal saturated liquids.
New correlation for the temperature-dependent viscosity for saturated liquids
NASA Astrophysics Data System (ADS)
Tian, Jianxiang; Zhang, Laibin
2016-11-01
Based on the recent progress on both the temperature dependence of surface tension [H. L. Yi, J. X. Tian, A. Mulero and I. Cachading, J. Therm. Anal. Calorim. 126 (2016) 1603, and the correlation between surface tension and viscosity of liquids [J. X. Tian and A. Mulero, Ind. Eng. Chem. Res. 53 (2014) 9499], we derived a new multiple parameter correlation to describe the temperature-dependent viscosity of liquids. This correlation is verified by comparing with data from NIST Webbook for 35 saturated liquids including refrigerants, hydrocarbons and others, in a wide temperature range from the triple point temperature to the one very near to the critical temperature. Results show that this correlation predicts the NIST data with high accuracy with absolute average deviation (AAD) less than 1% for 21 liquids and more than 3% for only four liquids, and is clearly better than the popularly used Vogel-Fulcher-Tamman (VFT) correlation.
Tong, Xiayu; Wang, Zhou-Jing
2016-09-19
This article develops a group decision framework with intuitionistic preference relations. An approach is first devised to rectify an inconsistent intuitionistic preference relation to derive an additive consistent one. A new aggregation operator, the so-called induced intuitionistic ordered weighted averaging (IIOWA) operator, is proposed to aggregate individual intuitionistic fuzzy judgments. By using the mean absolute deviation between the original and rectified intuitionistic preference relations as an order inducing variable, the rectified consistent intuitionistic preference relations are aggregated into a collective preference relation. This treatment is presumably able to assign different weights to different decision-makers' judgments based on the quality of their inputs (in terms of consistency of their original judgments). A solution procedure is then developed for tackling group decision problems with intuitionistic preference relations. A low carbon supplier selection case study is developed to illustrate how to apply the proposed decision model in practice.
Tong, Xiayu; Wang, Zhou-Jing
2016-01-01
This article develops a group decision framework with intuitionistic preference relations. An approach is first devised to rectify an inconsistent intuitionistic preference relation to derive an additive consistent one. A new aggregation operator, the so-called induced intuitionistic ordered weighted averaging (IIOWA) operator, is proposed to aggregate individual intuitionistic fuzzy judgments. By using the mean absolute deviation between the original and rectified intuitionistic preference relations as an order inducing variable, the rectified consistent intuitionistic preference relations are aggregated into a collective preference relation. This treatment is presumably able to assign different weights to different decision-makers’ judgments based on the quality of their inputs (in terms of consistency of their original judgments). A solution procedure is then developed for tackling group decision problems with intuitionistic preference relations. A low carbon supplier selection case study is developed to illustrate how to apply the proposed decision model in practice. PMID:27657097
Improving the Glucose Meter Error Grid With the Taguchi Loss Function.
Krouwer, Jan S
2016-07-01
Glucose meters often have similar performance when compared by error grid analysis. This is one reason that other statistics such as mean absolute relative deviation (MARD) are used to further differentiate performance. The problem with MARD is that too much information is lost. But additional information is available within the A zone of an error grid by using the Taguchi loss function. Applying the Taguchi loss function gives each glucose meter difference from reference a value ranging from 0 (no error) to 1 (error reaches the A zone limit). Values are averaged over all data which provides an indication of risk of an incorrect medical decision. This allows one to differentiate glucose meter performance for the common case where meters have a high percentage of values in the A zone and no values beyond the B zone. Examples are provided using simulated data. © 2015 Diabetes Technology Society.
Gaonkar, Narayan; Vaidya, R G
2016-05-01
A simple method to estimate the density of biodiesel blend as simultaneous function of temperature and volume percent of biodiesel is proposed. Employing the Kay's mixing rule, we developed a model and investigated theoretically the density of different vegetable oil biodiesel blends as a simultaneous function of temperature and volume percent of biodiesel. Key advantage of the proposed model is that it requires only a single set of density values of components of biodiesel blends at any two different temperatures. We notice that the density of blend linearly decreases with increase in temperature and increases with increase in volume percent of the biodiesel. The lower values of standard estimate of error (SEE = 0.0003-0.0022) and absolute average deviation (AAD = 0.03-0.15 %) obtained using the proposed model indicate the predictive capability. The predicted values found good agreement with the recent available experimental data.
NASA Astrophysics Data System (ADS)
Eom, Seongyong; Ahn, Seongyool; Kang, Kijoong; Choi, Gyungmin
2017-12-01
In this study, a numerical model of activation and ohmic polarization is modified, taking into account the correlation function between surface properties and inner resistance. To investigate the correlation function, the surface properties of coal are changed by acid treatment, and the correlations between the inner resistance measured by half-cell tests and the surface characteristics are analyzed. A comparison between the model and experimental results demonstrates that the absolute average deviations for each fuel are less than 10%. The numerical results show that the sensitivities of the coal surface properties affecting polarization losses change depending on the operating temperature. The surface oxygen concentrations affect the activation polarization and the sensitivity decreased with increasing temperature. The surface ash of coal is an additional index to be considered along with ohmic polarization and it has the greatest effect on the surface properties at 973 K.
Wang, Xinxin; Lu, Xingmei; Zhou, Qing; Zhao, Yongsheng; Li, Xiaoqian; Zhang, Suojiang
2017-08-02
Refractive index is one of the important physical properties, which is widely used in separation and purification. In this study, the refractive index data of ILs were collected to establish a comprehensive database, which included about 2138 pieces of data from 1996 to 2014. The Group Contribution-Artificial Neural Network (GC-ANN) model and Group Contribution (GC) method were employed to predict the refractive index of ILs at different temperatures from 283.15 K to 368.15 K. Average absolute relative deviations (AARD) of the GC-ANN model and the GC method were 0.179% and 0.628%, respectively. The results showed that a GC-ANN model provided an effective way to estimate the refractive index of ILs, whereas the GC method was simple and extensive. In summary, both of the models were accurate and efficient approaches for estimating refractive indices of ILs.
Test of quantum electrodynamics by muonic atoms: An experimental contribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tauscher, L.; Backenstoss, G.; Fransson, K.
1975-08-18
The large unexplained deviations of the experimental muonic 4-3 transitions in Ba and 5-4 transitions in Pb from calculations were found not to be existent. The absolute energies of these transitions agree, on the average, with theory to within 10 eV: The differences between experimental and calculated energies E)-E) are +2plus-or-minus13 and -2plus-or-minus12 eV for themore » $mu$$sup -$- Ba 4f$sub 5$/$sub 2$-3d$sub 3$/$sub 2$ and 4f$sub 7$/$sub 2$-3d$sub 5$/$sub 2$ transitions, respectively, and 10plus-or-minus16 and -13plus-or-minus14 eV for the $mu$$sup -$-Pb 5g$sub 7$/$sub 2$-4f$sub 5$/$sub 2$ and 5g$sub 9$/$sub 2$- 4f$sub 7$/$sub 2$ transitions, respectively.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodenbush, C.M.; Viswanath, D.S.; Hsieh, F.H.
Data on thermal conductivity of liquids, as a function of temperature, are essential in the design of heat- and mass- transfer equipment. A number of correlations have been developed to predict thermal conductivity of liquids with limited success. Among the correlations proposed so far, only the correlation due to Nagvekar and Daubert is based on group contributions. In this paper, a new group contribution method is developed based on the Klaas and Viswanath method for prediction of thermal conductivity of liquids and the results are compared to the method of Nagvekar and Daubert and other existing correlations. The present methodmore » predicts thermal conductivity of some 228 liquids that encompass 1487 experimental data points with an average absolute deviation of 2.5%. The group contribution method is used to examine the temperature dependence of Prandtl number for vegetable oils.« less
Künzler, Thomas; Fotina, Irina; Stock, Markus; Georg, Dietmar
2009-12-21
The dosimetric performance of a Monte Carlo algorithm as implemented in a commercial treatment planning system (iPlan, BrainLAB) was investigated. After commissioning and basic beam data tests in homogenous phantoms, a variety of single regular beams and clinical field arrangements were tested in heterogeneous conditions (conformal therapy, arc therapy and intensity-modulated radiotherapy including simultaneous integrated boosts). More specifically, a cork phantom containing a concave-shaped target was designed to challenge the Monte Carlo algorithm in more complex treatment cases. All test irradiations were performed on an Elekta linac providing 6, 10 and 18 MV photon beams. Absolute and relative dose measurements were performed with ion chambers and near tissue equivalent radiochromic films which were placed within a transverse plane of the cork phantom. For simple fields, a 1D gamma (gamma) procedure with a 2% dose difference and a 2 mm distance to agreement (DTA) was applied to depth dose curves, as well as to inplane and crossplane profiles. The average gamma value was 0.21 for all energies of simple test cases. For depth dose curves in asymmetric beams similar gamma results as for symmetric beams were obtained. Simple regular fields showed excellent absolute dosimetric agreement to measurement values with a dose difference of 0.1% +/- 0.9% (1 standard deviation) at the dose prescription point. A more detailed analysis at tissue interfaces revealed dose discrepancies of 2.9% for an 18 MV energy 10 x 10 cm(2) field at the first density interface from tissue to lung equivalent material. Small fields (2 x 2 cm(2)) have their largest discrepancy in the re-build-up at the second interface (from lung to tissue equivalent material), with a local dose difference of about 9% and a DTA of 1.1 mm for 18 MV. Conformal field arrangements, arc therapy, as well as IMRT beams and simultaneous integrated boosts were in good agreement with absolute dose measurements in the heterogeneous phantom. For the clinical test cases, the average dose discrepancy was 0.5% +/- 1.1%. Relative dose investigations of the transverse plane for clinical beam arrangements were performed with a 2D gamma-evaluation procedure. For 3% dose difference and 3 mm DTA criteria, the average value for gamma(>1) was 4.7% +/- 3.7%, the average gamma(1%) value was 1.19 +/- 0.16 and the mean 2D gamma-value was 0.44 +/- 0.07 in the heterogeneous phantom. The iPlan MC algorithm leads to accurate dosimetric results under clinical test conditions.
Burghelea, Manuela; Verellen, Dirk; Poels, Kenneth; Gevaert, Thierry; Depuydt, Tom; Tournel, Koen; Hung, Cecilia; Simon, Viorica; Hiraoka, Masahiro; de Ridder, Mark
2015-07-15
The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry-ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation was calculated as the maximum 3-dimensional distance between the CP and the closest DetPositions. In the CP versus DetPositions comparison, an overall mean G/R deviation of 0.13°/0.16° ± 0.16°/0.16° was obtained, with a maximum G/R deviation of 0.6°/0.2°. For the LogActed versus DetPositions evaluation, the overall mean deviation was 0.08°/0.15° ± 0.10°/0.10° with a maximum G/R of 0.3°/0.4°. The largest decoupled deviations registered for gantry and ring were 0.6° and 0.4° respectively. No directional dependence was observed between clockwise and counterclockwise rotations. Doubling the dose resulted in a double number of detected points around each CP, and an angular deviation reduction in all cases. An independent geometric quality assurance approach was developed for DWA delivery verification and was successfully applied on diverse trajectories. Results showed that the Vero system is capable of following complex G/R trajectories with maximum deviations during DWA below 0.6°. Copyright © 2015 Elsevier Inc. All rights reserved.
N2/O2/H2 Dual-Pump Cars: Validation Experiments
NASA Technical Reports Server (NTRS)
OByrne, S.; Danehy, P. M.; Cutler, A. D.
2003-01-01
The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method is used to measure temperature and the relative species densities of N2, O2 and H2 in two experiments. Average values and root-mean-square (RMS) deviations are determined. Mean temperature measurements in a furnace containing air between 300 and 1800 K agreed with thermocouple measurements within 26 K on average, while mean mole fractions agree to within 1.6 % of the expected value. The temperature measurement standard deviation averaged 64 K while the standard deviation of the species mole fractions averaged 7.8% for O2 and 3.8% for N2, based on 200 single-shot measurements. Preliminary measurements have also been performed in a flat-flame burner for fuel-lean and fuel-rich flames. Temperature standard deviations of 77 K were measured, and the ratios of H2 to N2 and O2 to N2 respectively had standard deviations from the mean value of 12.3% and 10% of the measured ratio.
Santana, Juan A.; Krogel, Jaron T.; Kent, Paul R. C.; ...
2016-05-03
We have applied the diffusion quantum Monte Carlo (DMC) method to calculate the cohesive energy and the structural parameters of the binary oxides CaO, SrO, BaO, Sc 2O 3, Y 2O 3 and La 2O 3. The aim of our calculations is to systematically quantify the accuracy of the DMC method to study this type of metal oxides. The DMC results were compared with local and semi-local Density Functional Theory (DFT) approximations as well as with experimental measurements. The DMC method yields cohesive energies for these oxides with a mean absolute deviation from experimental measurements of 0.18(2) eV, while withmore » local and semi-local DFT approximations the deviation is 3.06 and 0.94 eV, respectively. For lattice constants, the mean absolute deviation in DMC, local and semi-local DFT approximations, are 0.017(1), 0.07 and 0.05 , respectively. In conclusion, DMC is highly accurate method, outperforming the local and semi-local DFT approximations in describing the cohesive energies and structural parameters of these binary oxides.« less
Multicentre dose audit for clinical trials of radiation therapy in Asia.
Mizuno, Hideyuki; Fukuda, Shigekazu; Fukumura, Akifumi; Nakamura, Yuzuru-Kutsutani; Jianping, Cao; Cho, Chul-Koo; Supriana, Nana; Dung, To Anh; Calaguas, Miriam Joy; Devi, C R Beena; Chansilpa, Yaowalak; Banu, Parvin Akhter; Riaz, Masooma; Esentayeva, Surya; Kato, Shingo; Karasawa, Kumiko; Tsujii, Hirohiko
2017-05-01
A dose audit of 16 facilities in 11 countries has been performed within the framework of the Forum for Nuclear Cooperation in Asia (FNCA) quality assurance program. The quality of radiation dosimetry varies because of the large variation in radiation therapy among the participating countries. One of the most important aspects of international multicentre clinical trials is uniformity of absolute dose between centres. The National Institute of Radiological Sciences (NIRS) in Japan has conducted a dose audit of participating countries since 2006 by using radiophotoluminescent glass dosimeters (RGDs). RGDs have been successfully applied to a domestic postal dose audit in Japan. The authors used the same audit system to perform a dose audit of the FNCA countries. The average and standard deviation of the relative deviation between the measured and intended dose among 46 beams was 0.4% and 1.5% (k = 1), respectively. This is an excellent level of uniformity for the multicountry data. However, of the 46 beams measured, a single beam exceeded the permitted tolerance level of ±5%. We investigated the cause for this and solved the problem. This event highlights the importance of external audits in radiation therapy. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.
A novel strategy for forensic age prediction by DNA methylation and support vector regression model
Xu, Cheng; Qu, Hongzhu; Wang, Guangyu; Xie, Bingbing; Shi, Yi; Yang, Yaran; Zhao, Zhao; Hu, Lan; Fang, Xiangdong; Yan, Jiangwei; Feng, Lei
2015-01-01
High deviations resulting from prediction model, gender and population difference have limited age estimation application of DNA methylation markers. Here we identified 2,957 novel age-associated DNA methylation sites (P < 0.01 and R2 > 0.5) in blood of eight pairs of Chinese Han female monozygotic twins. Among them, nine novel sites (false discovery rate < 0.01), along with three other reported sites, were further validated in 49 unrelated female volunteers with ages of 20–80 years by Sequenom Massarray. A total of 95 CpGs were covered in the PCR products and 11 of them were built the age prediction models. After comparing four different models including, multivariate linear regression, multivariate nonlinear regression, back propagation neural network and support vector regression, SVR was identified as the most robust model with the least mean absolute deviation from real chronological age (2.8 years) and an average accuracy of 4.7 years predicted by only six loci from the 11 loci, as well as an less cross-validated error compared with linear regression model. Our novel strategy provides an accurate measurement that is highly useful in estimating the individual age in forensic practice as well as in tracking the aging process in other related applications. PMID:26635134
NASA Astrophysics Data System (ADS)
Hemmat Esfe, Mohammad; Tatar, Afshin; Ahangar, Mohammad Reza Hassani; Rostamian, Hossein
2018-02-01
Since the conventional thermal fluids such as water, oil, and ethylene glycol have poor thermal properties, the tiny solid particles are added to these fluids to increase their heat transfer improvement. As viscosity determines the rheological behavior of a fluid, studying the parameters affecting the viscosity is crucial. Since the experimental measurement of viscosity is expensive and time consuming, predicting this parameter is the apt method. In this work, three artificial intelligence methods containing Genetic Algorithm-Radial Basis Function Neural Networks (GA-RBF), Least Square Support Vector Machine (LS-SVM) and Gene Expression Programming (GEP) were applied to predict the viscosity of TiO2/SAE 50 nano-lubricant with Non-Newtonian power-law behavior using experimental data. The correlation factor (R2), Average Absolute Relative Deviation (AARD), Root Mean Square Error (RMSE), and Margin of Deviation were employed to investigate the accuracy of the proposed models. RMSE values of 0.58, 1.28, and 6.59 and R2 values of 0.99998, 0.99991, and 0.99777 reveal the accuracy of the proposed models for respective GA-RBF, CSA-LSSVM, and GEP methods. Among the developed models, the GA-RBF shows the best accuracy.
A vibration-insensitive optical cavity and absolute determination of its ultrahigh stability.
Zhao, Y N; Zhang, J; Stejskal, A; Liu, T; Elman, V; Lu, Z H; Wang, L J
2009-05-25
We use the three-cornered-hat method to evaluate the absolute frequency stabilities of three different ultrastable reference cavities, one of which has a vibration-insensitive design that does not even require vibration isolation. An Nd:YAG laser and a diode laser are implemented as light sources. We observe approximately 1 Hz beat note linewidths between all three cavities. The measurement demonstrates that the vibration-insensitive cavity has a good frequency stability over the entire measurement time from 100 ms to 200 s. An absolute, correlation-removed Allan deviation of 1.4 x 10(-15) at s of this cavity is obtained, giving a frequency uncertainty of only 0.44 Hz.
Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven
2010-09-01
To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.
Wide-field absolute transverse blood flow velocity mapping in vessel centerline
NASA Astrophysics Data System (ADS)
Wu, Nanshou; Wang, Lei; Zhu, Bifeng; Guan, Caizhong; Wang, Mingyi; Han, Dingan; Tan, Haishu; Zeng, Yaguang
2018-02-01
We propose a wide-field absolute transverse blood flow velocity measurement method in vessel centerline based on absorption intensity fluctuation modulation effect. The difference between the light absorption capacities of red blood cells and background tissue under low-coherence illumination is utilized to realize the instantaneous and average wide-field optical angiography images. The absolute fuzzy connection algorithm is used for vessel centerline extraction from the average wide-field optical angiography. The absolute transverse velocity in the vessel centerline is then measured by a cross-correlation analysis according to instantaneous modulation depth signal. The proposed method promises to contribute to the treatment of diseases, such as those related to anemia or thrombosis.
Earthquakes Magnitude Predication Using Artificial Neural Network in Northern Red Sea Area
NASA Astrophysics Data System (ADS)
Alarifi, A. S.; Alarifi, N. S.
2009-12-01
Earthquakes are natural hazards that do not happen very often, however they may cause huge losses in life and property. Early preparation for these hazards is a key factor to reduce their damage and consequence. Since early ages, people tried to predicate earthquakes using simple observations such as strange or a typical animal behavior. In this paper, we study data collected from existing earthquake catalogue to give better forecasting for future earthquakes. The 16000 events cover a time span of 1970 to 2009, the magnitude range from greater than 0 to less than 7.2 while the depth range from greater than 0 to less than 100km. We propose a new artificial intelligent predication system based on artificial neural network, which can be used to predicate the magnitude of future earthquakes in northern Red Sea area including the Sinai Peninsula, the Gulf of Aqaba, and the Gulf of Suez. We propose a feed forward new neural network model with multi-hidden layers to predicate earthquakes occurrences and magnitudes in northern Red Sea area. Although there are similar model that have been published before in different areas, to our best knowledge this is the first neural network model to predicate earthquake in northern Red Sea area. Furthermore, we present other forecasting methods such as moving average over different interval, normally distributed random predicator, and uniformly distributed random predicator. In addition, we present different statistical methods and data fitting such as linear, quadratic, and cubic regression. We present a details performance analyses of the proposed methods for different evaluation metrics. The results show that neural network model provides higher forecast accuracy than other proposed methods. The results show that neural network achieves an average absolute error of 2.6% while an average absolute error of 3.8%, 7.3% and 6.17% for moving average, linear regression and cubic regression, respectively. In this work, we show an analysis of earthquakes data in northern Red Sea area for different statistics parameters such as correlation, mean, standard deviation, and other. This analysis is to provide a deep understand of the Seismicity of the area, and existing patterns.
In Vivo measurement of pediatric vocal fold motion using structured light laser projection.
Patel, Rita R; Donohue, Kevin D; Lau, Daniel; Unnikrishnan, Harikrishnan
2013-07-01
The aim of the study was to present the development of a miniature structured light laser projection endoscope and to quantify vocal fold length and vibratory features related to impact stress of the pediatric glottis using high-speed imaging. The custom-developed laser projection system consists of a green laser with a 4-mm diameter optics module at the tip of the endoscope, projecting 20 vertical laser lines on the glottis. Measurements of absolute phonatory vocal fold length, membranous vocal fold length, peak amplitude, amplitude-to-length ratio, average closing velocity, and impact velocity were obtained in five children (6-9 years), two adult male and three adult female participants without voice disorders, and one child (10 years) with bilateral vocal fold nodules during modal phonation. Independent measurements made on the glottal length of a vocal fold phantom demonstrated a 0.13mm bias error with a standard deviation of 0.23mm, indicating adequate precision and accuracy for measuring vocal fold structures and displacement. First, in vivo measurements of amplitude-to-length ratio, peak closing velocity, and impact velocity during phonation in pediatric population and a child with vocal fold nodules are reported. The proposed laser projection system can be used to obtain in vivo measurements of absolute length and vibratory features in children and adults. Children have large amplitude-to-length ratio compared with typically developing adults, whereas nodules result in larger peak amplitude, amplitude-to-length ratio, average closing velocity, and impact velocity compared with typically developing children. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Brassey, Charlotte A.; Margetts, Lee; Kitchener, Andrew C.; Withers, Philip J.; Manning, Phillip L.; Sellers, William I.
2013-01-01
Classic beam theory is frequently used in biomechanics to model the stress behaviour of vertebrate long bones, particularly when creating intraspecific scaling models. Although methodologically straightforward, classic beam theory requires complex irregular bones to be approximated as slender beams, and the errors associated with simplifying complex organic structures to such an extent are unknown. Alternative approaches, such as finite element analysis (FEA), while much more time-consuming to perform, require no such assumptions. This study compares the results obtained using classic beam theory with those from FEA to quantify the beam theory errors and to provide recommendations about when a full FEA is essential for reasonable biomechanical predictions. High-resolution computed tomographic scans of eight vertebrate long bones were used to calculate diaphyseal stress owing to various loading regimes. Under compression, FEA values of minimum principal stress (σmin) were on average 142 per cent (±28% s.e.) larger than those predicted by beam theory, with deviation between the two models correlated to shaft curvature (two-tailed p = 0.03, r2 = 0.56). Under bending, FEA values of maximum principal stress (σmax) and beam theory values differed on average by 12 per cent (±4% s.e.), with deviation between the models significantly correlated to cross-sectional asymmetry at midshaft (two-tailed p = 0.02, r2 = 0.62). In torsion, assuming maximum stress values occurred at the location of minimum cortical thickness brought beam theory and FEA values closest in line, and in this case FEA values of τtorsion were on average 14 per cent (±5% s.e.) higher than beam theory. Therefore, FEA is the preferred modelling solution when estimates of absolute diaphyseal stress are required, although values calculated by beam theory for bending may be acceptable in some situations. PMID:23173199
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacFadden, Derek; Zhang Beibei; Brock, Kristy K.
Purpose: Increasing the magnetic resonance imaging (MRI) field strength can improve image resolution and quality, but concerns remain regarding the influence on geometric fidelity. The objectives of the present study were to spatially investigate the effect of 3-Tesla (3T) MRI on clinical target localization for stereotactic radiosurgery. Methods and Materials: A total of 39 patients were enrolled in a research ethics board-approved prospective clinical trial. Imaging (1.5T and 3T MRI and computed tomography) was performed after stereotactic frame placement. Stereotactic target localization at 1.5T vs. 3T was retrospectively analyzed in a representative cohort of patients with tumor (n = 4)more » and functional (n = 5) radiosurgical targets. The spatial congruency of the tumor gross target volumes was determined by the mean discrepancy between the average gross target volume surfaces at 1.5T and 3T. Reproducibility was assessed by the displacement from an averaged surface and volume congruency. Spatial congruency and the reproducibility of functional radiosurgical targets was determined by comparing the mean and standard deviation of the isocenter coordinates. Results: Overall, the mean absolute discrepancy across all patients was 0.67 mm (95% confidence interval, 0.51-0.83), significantly <1 mm (p < .010). No differences were found in the overall interuser target volume congruence (mean, 84% for 1.5T vs. 84% for 3T, p > .4), and the gross target volume surface mean displacements were similar within and between users. The overall average isocenter coordinate discrepancy for the functional targets at 1.5T and 3T was 0.33 mm (95% confidence interval, 0.20-0.48), with no patient-specific differences between the mean values (p >.2) or standard deviations (p >.1). Conclusion: Our results have provided clinically relevant evidence supporting the spatial validity of 3T MRI for use in stereotactic radiosurgery under the imaging conditions used.« less
[A new kinematics method of determing elbow rotation axis and evaluation of its feasibility].
Han, W; Song, J; Wang, G Z; Ding, H; Li, G S; Gong, M Q; Jiang, X Y; Wang, M Y
2016-04-18
To study a new positioning method of elbow external fixation rotation axis, and to evaluate its feasibility. Four normal adult volunteers and six Sawbone elbow models were brought into this experiment. The kinematic data of five elbow flexion were collected respectively by optical positioning system. The rotation axes of the elbow joints were fitted by the least square method. The kinematic data and fitting results were visually displayed. According to the fitting results, the average moving planes and rotation axes were calculated. Thus, the rotation axes of new kinematic methods were obtained. By using standard clinical methods, the entrance and exit points of rotation axes of six Sawbone elbow models were located under X-ray. And The kirschner wires were placed as the representatives of rotation axes using traditional positioning methods. Then, the entrance point deviation, the exit point deviation and the angle deviation of two kinds of located rotation axes were compared. As to the four volunteers, the indicators represented circular degree and coplanarity of elbow flexion movement trajectory of each volunteer were both about 1 mm. All the distance deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 3 mm. All the angle deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 5°. As to the six Sawbone models, the average entrance point deviations, the average exit point deviations and the average angle deviations of two different rotation axes determined by two kinds of located methods were respectively 1.697 2 mm, 1.838 3 mm and 1.321 7°. All the deviations were very small. They were all in an acceptable range of clinical practice. The values that represent circular degree and coplanarity of volunteer's elbow single curvature movement trajectory are very small. The result shows that the elbow single curvature movement can be regarded as the approximate fixed axis movement. The new method can replace the traditional method in accuracy. It can make up the deficiency of the traditional fixed axis method.
Mehri, M
2012-12-01
An artificial neural network (ANN) approach was used to develop feed-forward multilayer perceptron models to estimate the nutritional requirements of digestible lysine (dLys), methionine (dMet), and threonine (dThr) in broiler chicks. Sixty data lines representing response of the broiler chicks during 3 to 16 d of age to dietary levels of dLys (0.88-1.32%), dMet (0.42-0.58%), and dThr (0.53-0.87%) were obtained from literature and used to train the networks. The prediction values of ANN were compared with those of response surface methodology to evaluate the fitness of these 2 methods. The models were tested using R(2), mean absolute deviation, mean absolute percentage error, and absolute average deviation. The random search algorithm was used to optimize the developed ANN models to estimate the optimal values of dietary dLys, dMet, and dThr. The ANN models were used to assess the relative importance of each dietary input on the bird performance using sensitivity analysis. The statistical evaluations revealed the higher accuracy of ANN to predict the bird performance compared with response surface methodology models. The optimization results showed that the maximum BW gain may be obtained with dietary levels of 1.11, 0.51, and 0.78% of dLys, dMet, and dThr, respectively. Minimum feed conversion ratio may be achieved with dietary levels of 1.13, 0.54, 0.78% of dLys, dMet, and dThr, respectively. The sensitivity analysis on the models indicated that dietary Lys is the most important variable in the growth performance of the broiler chicks, followed by dietary Thr and Met. The results of this research revealed that the experimental data of a response-surface-methodology design could be successfully used to develop the well-designed ANN for pattern recognition of bird growth and optimization of nutritional requirements. The comparison between the 2 methods also showed that the statistical methods may have little effect on the ideal ratios of dMet and dThr to dLys in broiler chicks using multivariate optimization.
Loaiza-Echeverri, A M; Bergmann, J A G; Toral, F L B; Osorio, J P; Carmo, A S; Mendonça, L F; Moustacas, V S; Henry, M
2013-03-15
The objective was to use various nonlinear models to describe scrotal circumference (SC) growth in Guzerat bulls on three farms in the state of Minas Gerais, Brazil. The nonlinear models were: Brody, Logistic, Gompertz, Richards, Von Bertalanffy, and Tanaka, where parameter A is the estimated testis size at maturity, B is the integration constant, k is a maturating index and, for the Richards and Tanaka models, m determines the inflection point. In Tanaka, A is an indefinite size of the testis, and B and k adjust the shape and inclination of the curve. A total of 7410 SC records were obtained every 3 months from 1034 bulls with ages varying between 2 and 69 months (<240 days of age = 159; 241-365 days = 451; 366-550 days = 1443; 551-730 days = 1705; and >731 days = 3652 SC measurements). Goodness of fit was evaluated by coefficients of determination (R(2)), error sum of squares, average prediction error (APE), and mean absolute deviation. The Richards model did not reach the convergence criterion. The R(2) were similar for all models (0.68-0.69). The error sum of squares was lowest for the Tanaka model. All models fit the SC data poorly in the early and late periods. Logistic was the model which best estimated SC in the early phase (based on APE and mean absolute deviation). The Tanaka and Logistic models had the lowest APE between 300 and 1600 days of age. The Logistic model was chosen for analysis of the environmental influence on parameters A and k. Based on absolute growth rate, SC increased from 0.019 cm/d, peaking at 0.025 cm/d between 318 and 435 days of age. Farm, year, and season of birth significantly affected size of adult SC and SC growth rate. An increase in SC adult size (parameter A) was accompanied by decreased SC growth rate (parameter k). In conclusion, SC growth in Guzerat bulls was characterized by an accelerated growth phase, followed by decreased growth; this was best represented by the Logistic model. The inflection point occurred at approximately 376 days of age (mean SC of 17.9 cm). We inferred that early selection of testicular size might result in smaller testes at maturity. Copyright © 2013 Elsevier Inc. All rights reserved.
Extensive TD-DFT Benchmark: Singlet-Excited States of Organic Molecules.
Jacquemin, Denis; Wathelet, Valérie; Perpète, Eric A; Adamo, Carlo
2009-09-08
Extensive Time-Dependent Density Functional Theory (TD-DFT) calculations have been carried out in order to obtain a statistically meaningful analysis of the merits of a large number of functionals. To reach this goal, a very extended set of molecules (∼500 compounds, >700 excited states) covering a broad range of (bio)organic molecules and dyes have been investigated. Likewise, 29 functionals including LDA, GGA, meta-GGA, global hybrids, and long-range-corrected hybrids have been considered. Comparisons with both theoretical references and experimental measurements have been carried out. On average, the functionals providing the best match with reference data are, one the one hand, global hybrids containing between 22% and 25% of exact exchange (X3LYP, B98, PBE0, and mPW1PW91) and, on the other hand, a long-range-corrected hybrid with a less-rapidly increasing HF ratio, namely LC-ωPBE(20). Pure functionals tend to be less consistent, whereas functionals incorporating a larger fraction of exact exchange tend to underestimate significantly the transition energies. For most treated cases, the M05 and CAM-B3LYP schemes deliver fairly small deviations but do not outperform standard hybrids such as X3LYP or PBE0, at least within the vertical approximation. With the optimal functionals, one obtains mean absolute deviations smaller than 0.25 eV, though the errors significantly depend on the subset of molecules or states considered. As an illustration, PBE0 and LC-ωPBE(20) provide a mean absolute error of only 0.14 eV for the 228 states related to neutral organic dyes but are completely off target for cyanine-like derivatives. On the basis of comparisons with theoretical estimates, it also turned out that CC2 and TD-DFT errors are of the same order of magnitude, once the above-mentioned hybrids are selected.
Walorczyk, Stanisław; Drożdżyński, Dariusz; Kierzek, Roman
2015-01-01
A method was developed for pesticide analysis in samples of high chlorophyll content belonging to the group of minor crops. A new type of sorbent, known as ChloroFiltr, was employed for dispersive-solid phase extraction cleanup (dispersive-SPE) to reduce the unwanted matrix background prior to concurrent analysis by gas chromatography and ultra-performance liquid chromatography coupled to tandem quadrupole mass spectrometry (GC-MS/MS and UPLC-MS/MS). Validation experiments were carried out on green, unripe plants of lupin, white mustard and sorghum. The overall recoveries at the three spiking levels of 0.01, 0.05 and 0.5 mg kg(-1) fell in the range between 68 and 120% (98% on average) and 72-104% (93% on average) with relative standard deviation (RSD) values between 2 and 19% (7% on average) and 3-16% (6% on average) by GC-MS/MS and UPLC-MS/MS technique, respectively. Because of strong enhancement or suppression matrix effects (absolute values >20%) which were exhibited by about 80% of the pesticide and matrix combinations, acceptably accurate quantification was achieved by using matrix-matched standards. Up to now, the proposed method has been successfully used to study the dissipation patterns of pesticides after application on lupin, white mustard, soya bean, sunflower and field bean in experimental plot trials conducted in Poland. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Guochao; Tan, Lilong; Yan, Shuhua
2018-02-07
We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He-Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10 -8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions.
Tan, Lilong; Yan, Shuhua
2018-01-01
We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He–Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10−8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions. PMID:29414897
1986-03-01
Directly from Sample Bid VI-16 Example 3 VI-16 Determining the Zero Price Qiantity Demanded VI-26 Summary VI -31 CHAPrER VII, THE DETERMINATION OF NED...While the standard deviation and variance are absolute measures of dispersion, a relative measure of dispersion can also be computed. This measure is...refers to the closeness of fit between the estimates obtained from Zli e and the true population value. The only way of being absolutely i: o-.iat the
NASA Astrophysics Data System (ADS)
Qie, L.; Li, Z.; Li, L.; Li, K.; Li, D.; Xu, H.
2018-04-01
The Devaux-Vermeulen-Li method (DVL method) is a simple approach to retrieve aerosol optical parameters from the Sun-sky radiance measurements. This study inherited the previous works of retrieving aerosol single scattering albedo (SSA) and scattering phase function, the DVL method was modified to derive aerosol asymmetric factor (g). To assess the algorithm performance at various atmospheric aerosol conditions, retrievals from AERONET observations were implemented, and the results are compared with AERONET official products. The comparison shows that both the DVL SSA and g were well correlated with those of AERONET. The RMSD and the absolute value of MBD deviations between the SSAs are 0.025 and 0.015 respectively, well below the AERONET declared SSA uncertainty of 0.03 for all wavelengths. For asymmetry factor g, the RMSD deviations are smaller than 0.02 and the absolute values of MBDs smaller than 0.01 at 675, 870 and 1020 nm bands. Then, considering several factors probably affecting retrieval quality (i.e. the aerosol optical depth (AOD), the solar zenith angle, and the sky residual error, sphericity proportion and Ångström exponent), the deviations for SSA and g of these two algorithms were calculated at varying value intervals. Both the SSA and g deviations were found decrease with the AOD and the solar zenith angle, and increase with sky residual error. However, the deviations do not show clear sensitivity to the sphericity proportion and Ångström exponent. This indicated that the DVL algorithm is available for both large, non-spherical particles and spherical particles. The DVL results are suitable for the evaluation of aerosol direct radiative effects of different aerosol types.
NASA Astrophysics Data System (ADS)
Wang, Lei; Moltz, Jan H.; Bornemann, Lars; Hahn, Horst K.
2012-03-01
Precise size measurement of enlarged lymph nodes is a significant indicator for diagnosing malignancy, follow-up and therapy monitoring of cancer diseases. The presence of diverse sizes and shapes, inhomogeneous enhancement and the adjacency to neighboring structures with similar intensities, make the segmentation task challenging. We present a semi-automatic approach requiring minimal user interactions to fast and robustly segment the enlarged lymph nodes. First, a stroke approximating the largest diameter of a specific lymph node is drawn manually from which a volume of interest (VOI) is determined. Second, Based on the statistical analysis of the intensities on the dilated stroke area, a region growing procedure is utilized within the VOI to create an initial segmentation of the target lymph node. Third, a rotatable spiral-scanning technique is proposed to resample the 3D boundary surface of the lymph node to a 2D boundary contour in a transformed polar image. The boundary contour is found by seeking the optimal path in 2D polar image with dynamic programming algorithm and eventually transformed back to 3D. Ultimately, the boundary surface of the lymph node is determined using an interpolation scheme followed by post-processing steps. To test the robustness and efficiency of our method, a quantitative evaluation was conducted with a dataset of 315 lymph nodes acquired from 79 patients with lymphoma and melanoma. Compared to the reference segmentations, an average Dice coefficient of 0.88 with a standard deviation of 0.08, and an average absolute surface distance of 0.54mm with a standard deviation of 0.48mm, were achieved.
A Typology for Charting Socioeconomic Mortality Gradients: "Go Southwest".
Blakely, Tony; Disney, George; Atkinson, June; Teng, Andrea; Mackenbach, Johan P
2017-07-01
Holistic depiction of time-trends in average mortality rates, and absolute and relative inequalities, is challenging. We outline a typology for situations with falling average mortality rates (m↓; e.g., cardiovascular disease), rates stable over time (m-; e.g., some cancers), and increasing average mortality rates (m↑; e.g., suicide in some contexts). If we consider inequality trends on both the absolute (a) and relative (r) scales, there are 13 possible combination of m, a, and r trends over time. They can be mapped to graphs with relative inequality (log relative index of inequality [RII]; r) on the y axis, log average mortality rate on the x axis (m), and absolute inequality (slope index of inequality; SII; a) as contour lines. We illustrate this by plotting adult mortality trends: (1) by household income from 1981 to 2011 for New Zealand, and (2) by education for European countries. Types range from the "best" m↓a↓r↓ (average, absolute, and relative inequalities all decreasing; southwest movement in graphs) to the "worst" m↑a↑r↑ (northeast). Mortality typologies in New Zealand (all-cause, cardiovascular disease, nonlung cancer, and unintentional injury) were all m↓r↑ (northwest), but variable with respect to absolute inequality. Most European typologies were m↓r↑ types (northwest; e.g., Finland), but with notable exceptions of m-a↑r↑ (north; e.g., Hungary) and "best" or southwest m↓a↓r↓ for Spain (Barcelona) females. Our typology and corresponding graphs provide a convenient way to summarize and understand past trends in inequalities in mortality, and hold potential for projecting future trends and target setting.
Fredriksson, Ingemar; Burdakov, Oleg; Larsson, Marcus; Strömberg, Tomas
2013-12-01
The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source-detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1.2 mm in the same fiber-optic probe. Data are analyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayered tissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information. Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluate the method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1 percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and 23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations are presented. The method offers several advantages such as simultaneous quantification of RBC tissue fraction and oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speed resolved, absolute (% RBC×mm/s), and more accurate due to the combination with DRS.
NASA Astrophysics Data System (ADS)
Fredriksson, Ingemar; Burdakov, Oleg; Larsson, Marcus; Strömberg, Tomas
2013-12-01
The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source-detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1.2 mm in the same fiber-optic probe. Data are analyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayered tissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information. Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluate the method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1 percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and 23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations are presented. The method offers several advantages such as simultaneous quantification of RBC tissue fraction and oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speed resolved, absolute (% RBC×mm/s), and more accurate due to the combination with DRS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morley, Steven
The PyForecastTools package provides Python routines for calculating metrics for model validation, forecast verification and model comparison. For continuous predictands the package provides functions for calculating bias (mean error, mean percentage error, median log accuracy, symmetric signed bias), and for calculating accuracy (mean squared error, mean absolute error, mean absolute scaled error, normalized RMSE, median symmetric accuracy). Convenience routines to calculate the component parts (e.g. forecast error, scaled error) of each metric are also provided. To compare models the package provides: generic skill score; percent better. Robust measures of scale including median absolute deviation, robust standard deviation, robust coefficient ofmore » variation and the Sn estimator are all provided by the package. Finally, the package implements Python classes for NxN contingency tables. In the case of a multi-class prediction, accuracy and skill metrics such as proportion correct and the Heidke and Peirce skill scores are provided as object methods. The special case of a 2x2 contingency table inherits from the NxN class and provides many additional metrics for binary classification: probability of detection, probability of false detection, false alarm ration, threat score, equitable threat score, bias. Confidence intervals for many of these quantities can be calculated using either the Wald method or Agresti-Coull intervals.« less
Uncertainty Analysis of Downscaled CMIP5 Precipitation Data for Louisiana, USA
NASA Astrophysics Data System (ADS)
Sumi, S. J.; Tamanna, M.; Chivoiu, B.; Habib, E. H.
2014-12-01
The downscaled CMIP3 and CMIP5 Climate and Hydrology Projections dataset contains fine spatial resolution translations of climate projections over the contiguous United States developed using two downscaling techniques (monthly Bias Correction Spatial Disaggregation (BCSD) and daily Bias Correction Constructed Analogs (BCCA)). The objective of this study is to assess the uncertainty of the CMIP5 downscaled general circulation models (GCM). We performed an analysis of the daily, monthly, seasonal and annual variability of precipitation downloaded from the Downscaled CMIP3 and CMIP5 Climate and Hydrology Projections website for the state of Louisiana, USA at 0.125° x 0.125° resolution. A data set of daily gridded observations of precipitation of a rectangular boundary covering Louisiana is used to assess the validity of 21 downscaled GCMs for the 1950-1999 period. The following statistics are computed using the CMIP5 observed dataset with respect to the 21 models: the correlation coefficient, the bias, the normalized bias, the mean absolute error (MAE), the mean absolute percentage error (MAPE), and the root mean square error (RMSE). A measure of variability simulated by each model is computed as the ratio of its standard deviation, in both space and time, to the corresponding standard deviation of the observation. The correlation and MAPE statistics are also computed for each of the nine climate divisions of Louisiana. Some of the patterns that we observed are: 1) Average annual precipitation rate shows similar spatial distribution for all the models within a range of 3.27 to 4.75 mm/day from Northwest to Southeast. 2) Standard deviation of summer (JJA) precipitation (mm/day) for the models maintains lower value than the observation whereas they have similar spatial patterns and range of values in winter (NDJ). 3) Correlation coefficients of annual precipitation of models against observation have a range of -0.48 to 0.36 with variable spatial distribution by model. 4) Most of the models show negative correlation coefficients in summer and positive in winter. 5) MAE shows similar spatial distribution for all the models within a range of 5.20 to 7.43 mm/day from Northwest to Southeast of Louisiana. 6) Highest values of correlation coefficients are found at seasonal scale within a range of 0.36 to 0.46.
Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.
1998-01-01
A method for generating a validated measurement of a process parameter at a point in time by using a plurality of individual sensor inputs from a scan of said sensors at said point in time. The sensor inputs from said scan are stored and a first validation pass is initiated by computing an initial average of all stored sensor inputs. Each sensor input is deviation checked by comparing each input including a preset tolerance against the initial average input. If the first deviation check is unsatisfactory, the sensor which produced the unsatisfactory input is flagged as suspect. It is then determined whether at least two of the inputs have not been flagged as suspect and are therefore considered good inputs. If two or more inputs are good, a second validation pass is initiated by computing a second average of all the good sensor inputs, and deviation checking the good inputs by comparing each good input including a present tolerance against the second average. If the second deviation check is satisfactory, the second average is displayed as the validated measurement and the suspect sensor as flagged as bad. A validation fault occurs if at least two inputs are not considered good, or if the second deviation check is not satisfactory. In the latter situation the inputs from each of all the sensors are compared against the last validated measurement and the value from the sensor input that deviates the least from the last valid measurement is displayed.
Inter-comparison of precipitable water among reanalyses and its effect on downscaling in the tropics
NASA Astrophysics Data System (ADS)
Takahashi, H. G.; Fujita, M.; Hara, M.
2012-12-01
This paper compared precipitable water (PW) among four major reanalyses. In addition, we also investigated the effect of the boundary conditions on downscaling in the tropics, using a regional climate model. The spatial pattern of PW in the reanalyses agreed closely with observations. However, the absolute amounts of PW in some reanalyses were very small compared to observations. The discrepancies of the 12-year mean PW in July over the Southeast Asian monsoon region exceeded the inter-annual standard deviation of the PW. There was also a discrepancy in tropical PWs throughout the year, an indication that the problem is not regional, but global. The downscaling experiments were conducted, which were forced by the different four reanalyses. The atmospheric circulation, including monsoon westerlies and various disturbances, was very small among the reanalyses. However, simulated precipitation was only 60 % of observed precipitation, although the dry bias in the boundary conditions was only 6 %. This result indicates that dry bias has large effects on precipitation in downscaling over the tropics. This suggests that a simulated regional climate downscaled from ensemble-mean boundary conditions is quite different from an ensemble-mean regional climate averaged over the several regional ones downscaled from boundary conditions of the ensemble members in the tropics. Downscaled models can provide realistic simulations of regional tropical climates only if the boundary conditions include realistic absolute amounts of PW. Use of boundary conditions that include realistic absolute amounts of PW in downscaling in the tropics is imperative at the present time. This work was partly supported by the Global Environment Research Fund (RFa-1101) of the Ministry of the Environment, Japan.
Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health
Hersek, Sinan; Töreyin, Hakan; Teague, Caitlin N.; Millard-Stafford, Mindy L.; Jeong, Hyeon-Ki; Bavare, Miheer M.; Wolkoff, Paul; Sawka, Michael N.; Inan, Omer T.
2017-01-01
Objective We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Methods Five separate experiments were performed to demonstrate the: (1) ability of the EBI system to assess knee injury and recovery; (2) inter-day variability of knee EBI measurements; (3) sensitivity of the system to small changes in interstitial fluid volume; (4) reducing the error of EBI measurements using acceleration signals; (5) use of the system with dry electrodes integrated to a wearable knee wrap. Results (1) The absolute difference in resistance (R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p<0.05); the absolute difference in R decreased significantly (p<0.05) in injured subjects following rehabilitation. (2) The average inter-day variability (standard deviation) of the absolute difference in knee R was 2.5Ω, and for X was, 1.2 Ω. (3) Local heating/cooling resulted in a significant decrease/increase in knee R (p<0.01). (4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. (5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated (r2 = 0.8 and 0.9, respectively). Conclusion This work demonstrates the use of wearable EBI measurements in monitoring knee joint health. Significance The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation. PMID:28026745
Wearable Vector Electrical Bioimpedance System to Assess Knee Joint Health.
Hersek, Sinan; Toreyin, Hakan; Teague, Caitlin N; Millard-Stafford, Mindy L; Jeong, Hyeon-Ki; Bavare, Miheer M; Wolkoff, Paul; Sawka, Michael N; Inan, Omer T
2017-10-01
We designed and validated a portable electrical bioimpedance (EBI) system to quantify knee joint health. Five separate experiments were performed to demonstrate the: 1) ability of the EBI system to assess knee injury and recovery; 2) interday variability of knee EBI measurements; 3) sensitivity of the system to small changes in interstitial fluid volume; 4) reducing the error of EBI measurements using acceleration signals; and 5) use of the system with dry electrodes integrated to a wearable knee wrap. 1) The absolute difference in resistance ( R) and reactance (X) from the left to the right knee was able to distinguish injured and healthy knees (p < 0.05); the absolute difference in R decreased significantly (p < 0.05) in injured subjects following rehabilitation. 2) The average interday variability (standard deviation) of the absolute difference in knee R was 2.5 Ω and for X was 1.2 Ω. 3) Local heating/cooling resulted in a significant decrease/increase in knee R (p < 0.01). 4) The proposed subject position detection algorithm achieved 97.4% leave-one subject out cross-validated accuracy and 98.2% precision in detecting when the subject is in the correct position to take measurements. 5) Linear regression between the knee R and X measured using the wet electrodes and the designed wearable knee wrap were highly correlated ( R 2 = 0.8 and 0.9, respectively). This study demonstrates the use of wearable EBI measurements in monitoring knee joint health. The proposed wearable system has the potential for assessing knee joint health outside the clinic/lab and help guide rehabilitation.
Fidelity deviation in quantum teleportation
NASA Astrophysics Data System (ADS)
Bang, Jeongho; Ryu, Junghee; Kaszlikowski, Dagomir
2018-04-01
We analyze the performance of quantum teleportation in terms of average fidelity and fidelity deviation. The average fidelity is defined as the average value of the fidelities over all possible input states and the fidelity deviation is their standard deviation, which is referred to as a concept of fluctuation or universality. In the analysis, we find the condition to optimize both measures under a noisy quantum channel—we here consider the so-called Werner channel. To characterize our results, we introduce a 2D space defined by the aforementioned measures, in which the performance of the teleportation is represented as a point with the channel noise parameter. Through further analysis, we specify some regions drawn for different channel conditions, establishing the connection to the dissimilar contributions of the entanglement to the teleportation and the Bell inequality violation.
Genheden, Samuel
2017-10-01
We present the estimation of solvation free energies of small solutes in water, n-octanol and hexane using molecular dynamics simulations with two MARTINI models at different resolutions, viz. the coarse-grained (CG) and the hybrid all-atom/coarse-grained (AA/CG) models. From these estimates, we also calculate the water/hexane and water/octanol partition coefficients. More than 150 small, organic molecules were selected from the Minnesota solvation database and parameterized in a semi-automatic fashion. Using either the CG or hybrid AA/CG models, we find considerable deviations between the estimated and experimental solvation free energies in all solvents with mean absolute deviations larger than 10 kJ/mol, although the correlation coefficient is between 0.55 and 0.75 and significant. There is also no difference between the results when using the non-polarizable and polarizable water model, although we identify some improvements when using the polarizable model with the AA/CG solutes. In contrast to the estimated solvation energies, the estimated partition coefficients are generally excellent with both the CG and hybrid AA/CG models, giving mean absolute deviations between 0.67 and 0.90 log units and correlation coefficients larger than 0.85. We analyze the error distribution further and suggest avenues for improvements.
NASA Astrophysics Data System (ADS)
Genheden, Samuel
2017-10-01
We present the estimation of solvation free energies of small solutes in water, n-octanol and hexane using molecular dynamics simulations with two MARTINI models at different resolutions, viz. the coarse-grained (CG) and the hybrid all-atom/coarse-grained (AA/CG) models. From these estimates, we also calculate the water/hexane and water/octanol partition coefficients. More than 150 small, organic molecules were selected from the Minnesota solvation database and parameterized in a semi-automatic fashion. Using either the CG or hybrid AA/CG models, we find considerable deviations between the estimated and experimental solvation free energies in all solvents with mean absolute deviations larger than 10 kJ/mol, although the correlation coefficient is between 0.55 and 0.75 and significant. There is also no difference between the results when using the non-polarizable and polarizable water model, although we identify some improvements when using the polarizable model with the AA/CG solutes. In contrast to the estimated solvation energies, the estimated partition coefficients are generally excellent with both the CG and hybrid AA/CG models, giving mean absolute deviations between 0.67 and 0.90 log units and correlation coefficients larger than 0.85. We analyze the error distribution further and suggest avenues for improvements.
Absolute binding free energy calculations of CBClip host–guest systems in the SAMPL5 blind challenge
Tofoleanu, Florentina; Pickard, Frank C.; König, Gerhard; Huang, Jing; Damjanović, Ana; Baek, Minkyung; Seok, Chaok; Brooks, Bernard R.
2016-01-01
Herein, we report the absolute binding free energy calculations of CBClip complexes in the SAMPL5 blind challenge. Initial conformations of CBClip complexes were obtained using docking and molecular dynamics simulations. Free energy calculations were performed using thermodynamic integration (TI) with soft-core potentials and Bennett’s acceptance ratio (BAR) method based on a serial insertion scheme. We compared the results obtained with TI simulations with soft-core potentials and Hamiltonian replica exchange simulations with the serial insertion method combined with the BAR method. The results show that the difference between the two methods can be mainly attributed to the van der Waals free energies, suggesting that either the simulations used for TI or the simulations used for BAR, or both are not fully converged and the two sets of simulations may have sampled difference phase space regions. The penalty scores of force field parameters of the 10 guest molecules provided by CHARMM Generalized Force Field can be an indicator of the accuracy of binding free energy calculations. Among our submissions, the combination of docking and TI performed best, which yielded the root mean square deviation of 2.94 kcal/mol and an average unsigned error of 3.41 kcal/mol for the ten guest molecules. These values were best overall among all participants. However, our submissions had little correlation with experiments. PMID:27677749
Yang, Eunjoo; Park, Hyun Woo; Choi, Yeon Hwa; Kim, Jusim; Munkhdalai, Lkhagvadorj; Musa, Ibrahim; Ryu, Keun Ho
2018-05-11
Early detection of infectious disease outbreaks is one of the important and significant issues in syndromic surveillance systems. It helps to provide a rapid epidemiological response and reduce morbidity and mortality. In order to upgrade the current system at the Korea Centers for Disease Control and Prevention (KCDC), a comparative study of state-of-the-art techniques is required. We compared four different temporal outbreak detection algorithms: the CUmulative SUM (CUSUM), the Early Aberration Reporting System (EARS), the autoregressive integrated moving average (ARIMA), and the Holt-Winters algorithm. The comparison was performed based on not only 42 different time series generated taking into account trends, seasonality, and randomly occurring outbreaks, but also real-world daily and weekly data related to diarrhea infection. The algorithms were evaluated using different metrics. These were namely, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), F1 score, symmetric mean absolute percent error (sMAPE), root-mean-square error (RMSE), and mean absolute deviation (MAD). Although the comparison results showed better performance for the EARS C3 method with respect to the other algorithms, despite the characteristics of the underlying time series data, Holt⁻Winters showed better performance when the baseline frequency and the dispersion parameter values were both less than 1.5 and 2, respectively.
Schlüns, Danny; Franchini, Mirko; Götz, Andreas W; Neugebauer, Johannes; Jacob, Christoph R; Visscher, Lucas
2017-02-05
We present a new implementation of analytical gradients for subsystem density-functional theory (sDFT) and frozen-density embedding (FDE) into the Amsterdam Density Functional program (ADF). The underlying theory and necessary expressions for the implementation are derived and discussed in detail for various FDE and sDFT setups. The parallel implementation is numerically verified and geometry optimizations with different functional combinations (LDA/TF and PW91/PW91K) are conducted and compared to reference data. Our results confirm that sDFT-LDA/TF yields good equilibrium distances for the systems studied here (mean absolute deviation: 0.09 Å) compared to reference wave-function theory results. However, sDFT-PW91/PW91k quite consistently yields smaller equilibrium distances (mean absolute deviation: 0.23 Å). The flexibility of our new implementation is demonstrated for an HCN-trimer test system, for which several different setups are applied. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
A Visual Model for the Variance and Standard Deviation
ERIC Educational Resources Information Center
Orris, J. B.
2011-01-01
This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.
SU-F-T-552: A One-Year Evaluation of the QABeamChecker+ for Use with the CyberKnife System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gersh, J; Spectrum Medical Physics, LLC, Greenville, SC
Purpose: By attaching an adapter plate with fiducial markers to the QA BeamChecker+ (Standard Imaging, Inc., Middleton, WI), the output of the CyberKnife can be accurately, efficiently, and consistently evaluated. The adapter plate, known as the Cutting Board, allows for automated alignment of the QABC+ using the CK’s stereoscopic kV image-based treatment localization system (TLS). Described herein is an evaluation of the system following a year of clinical utilization. Methods: Based on a CT scan of the QABC+ and CB, a treatment plan is generated which delivers a beam to each of the 5 plane-parallel ionization chambers. Following absolute calibrationmore » of the CK, the QA plan is delivered, and baseline measurements are acquired (and automatically corrected for temperature and pressure). This test was performed at the beginning of each treatment day for a year. A calibration evaluation (using a water-equivalent slab and short thimble chamber) is performed every four weeks, or whenever the QABC+ detects a deviation of more than 1.0%. Results: During baseline evaluation, repeat measurements (n=10) were performed, with an average output of 0.25% with an SD of 0.11%. As a test of the reposition of the QABC+ and CB, ten additional measurements were performed where between each acquisition, the entire system was removed and re-positioned using the TLS. The average output deviation was 0.30% with a SD of 0.13%. During the course of the year, 187 QABC+ measurements and 13 slab-based measurements were performed. The output measurements of the QABC+ correlated well with slab-based measurements (R2=0.909). Conclusion: By using the QABC+ and CB, daily output was evaluated accurately, efficiently, and consistently. From setup to break-down (including analysis), this test required 5 minutes instead of approximately 15 using traditional techniques (collimator-mounted ionization chambers). Additionally, by automatically saving resultant output deviation to a database, trend analysis was simplified. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.« less
Titah, Harmin Sulistiyaning; Halmi, Mohd Izuan Effendi Bin; Abdullah, Siti Rozaimah Sheikh; Hasan, Hassimi Abu; Idris, Mushrifah; Anuar, Nurina
2018-06-07
In this study, the removal of arsenic (As) by plant, Ludwigia octovalvis, in a pilot reed bed was optimized. A Box-Behnken design was employed including a comparative analysis of both Response Surface Methodology (RSM) and an Artificial Neural Network (ANN) for the prediction of maximum arsenic removal. The predicted optimum condition using the desirability function of both models was 39 mg kg -1 for the arsenic concentration in soil, an elapsed time of 42 days (the sampling day) and an aeration rate of 0.22 L/min, with the predicted values of arsenic removal by RSM and ANN being 72.6% and 71.4%, respectively. The validation of the predicted optimum point showed an actual arsenic removal of 70.6%. This was achieved with the deviation between the validation value and the predicted values being within 3.49% (RSM) and 1.87% (ANN). The performance evaluation of the RSM and ANN models showed that ANN performs better than RSM with a higher R 2 (0.97) close to 1.0 and very small Average Absolute Deviation (AAD) (0.02) and Root Mean Square Error (RMSE) (0.004) values close to zero. Both models were appropriate for the optimization of arsenic removal with ANN demonstrating significantly higher predictive and fitting ability than RSM.
Judging in Rhythmic Gymnastics at Different Levels of Performance.
Leandro, Catarina; Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta
2017-12-01
This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach's alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges' difficulty scores, the Kendall's coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach's alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level.
Judging in Rhythmic Gymnastics at Different Levels of Performance
Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta
2017-01-01
Abstract This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach’s alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges’ difficulty scores, the Kendall’s coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach’s alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level. PMID:29339996
Measuring (subglacial) bedform orientation, length, and longitudinal asymmetry - Method assessment.
Jorge, Marco G; Brennand, Tracy A
2017-01-01
Geospatial analysis software provides a range of tools that can be used to measure landform morphometry. Often, a metric can be computed with different techniques that may give different results. This study is an assessment of 5 different methods for measuring longitudinal, or streamlined, subglacial bedform morphometry: orientation, length and longitudinal asymmetry, all of which require defining a longitudinal axis. The methods use the standard deviational ellipse (not previously applied in this context), the longest straight line fitting inside the bedform footprint (2 approaches), the minimum-size footprint-bounding rectangle, and Euler's approximation. We assess how well these methods replicate morphometric data derived from a manually mapped (visually interpreted) longitudinal axis, which, though subjective, is the most typically used reference. A dataset of 100 subglacial bedforms covering the size and shape range of those in the Puget Lowland, Washington, USA is used. For bedforms with elongation > 5, deviations from the reference values are negligible for all methods but Euler's approximation (length). For bedforms with elongation < 5, most methods had small mean absolute error (MAE) and median absolute deviation (MAD) for all morphometrics and thus can be confidently used to characterize the central tendencies of their distributions. However, some methods are better than others. The least precise methods are the ones based on the longest straight line and Euler's approximation; using these for statistical dispersion analysis is discouraged. Because the standard deviational ellipse method is relatively shape invariant and closely replicates the reference values, it is the recommended method. Speculatively, this study may also apply to negative-relief, and fluvial and aeolian bedforms.
Zhang, Yunyun; Yan, Jing; Fu, Yi; Chen, Shengdi
2013-01-01
Objective To compare the accuracy of formula 1/2ABC with 2/3SH on volume estimation for hypertensive infratentorial hematoma. Methods One hundred and forty-seven CT scans diagnosed as hypertensive infratentorial hemorrhage were reviewed. Based on the shape, hematomas were categorized as regular or irregular. Multilobular was defined as a special shape of irregular. Hematoma volume was calculated employing computer-assisted volumetric analysis (CAVA), 1/2ABC and 2/3SH, respectively. Results The correlation coefficients between 1/2ABC (or 2/3SH) and CAVA were greater than 0.900 in all subgroups. There were neither significant differences in absolute values of volume deviation nor percentage deviation between 1/2ABC and 2/3SH for regular hemorrhage (P>0.05). While for cerebellar, brainstem and irregular hemorrhages, the absolute values of volume deviation and percentage deviation by formula 1/2ABC were greater than 2/3SH (P<0.05). 1/2ABC and 2/3SH underestimated hematoma volume each by 10% and 5% for cerebellar hemorrhage, 14% and 9% for brainstem hemorrhage, 19% and 16% for regular hemorrhage, 9% and 3% for irregular hemorrhage, respectively. In addition, for the multilobular hemorrhage, 1/2ABC underestimated the volume by 9% while 2/3SH overestimated it by 2%. Conclusions For regular hemorrhage volume calculation, the accuracy of 2/3SH is similar to 1/2ABC. While for cerebellar, brainstem or irregular hemorrhages (including multilobular), 2/3SH is more accurate than 1/2ABC. PMID:23638025
Anterior capsulotomy with an ultrashort-pulse laser.
Tackman, Ramon Naranjo; Kuri, Jorge Villar; Nichamin, Louis D Skip; Edwards, Keith
2011-05-01
To assess the precision of laser anterior capsulotomy compared with that of manual continuous curvilinear capsulorhexis (CCC). Asociación Para Evitar La Ceguera en México IAP, Hospital Dr. Luis Sánchez Bulnes, Mexico City, Mexico. Nonrandomized single-center clinical trial. In patients presenting for cataract surgery, the LensAR Laser System was used to create a laser anterior capsulotomy of the surgeon's desired size. Capsule buttons were retrieved and measured and then compared with buttons retrieved from eyes having a manually torn CCC. Deviation from the intended diameter and the regularity of shape were assessed. When removing the capsule buttons at the start of surgery, the surgeon rated the ease of removal on a scale of 1 to 10 (1 = required manual capsulorhexis around the whole diameter; 10 = button free floating or required no manual detachment from remaining capsule during removal). The mean deviation from the intended diameter was 0.16 mm ± 0.17 (SD) for laser anterior capsulotomy and 0.42 ± 0.54 mm for CCC (P=.03). The mean absolute deviation from the intended diameter was 0.20 ± 0.12 mm and 0.49 ± 0.47 mm, respectively (P=.003). The mean of the average squared residuals was 0.01 ± 0.03 and 0.02 ± 0.04, respectively (P=.09). The median rating of the ease of removal was 9 (range 5 to 10). Laser anterior capsulotomy created a more precise capsule opening than CCC, and the buttons created by the laser procedure were easy to remove at the beginning of cataract surgery. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
An image registration based ultrasound probe calibration
NASA Astrophysics Data System (ADS)
Li, Xin; Kumar, Dinesh; Sarkar, Saradwata; Narayanan, Ram
2012-02-01
Reconstructed 3D ultrasound of prostate gland finds application in several medical areas such as image guided biopsy, therapy planning and dose delivery. In our application, we use an end-fire probe rotated about its axis to acquire a sequence of rotational slices to reconstruct 3D TRUS (Transrectal Ultrasound) image. The image acquisition system consists of an ultrasound transducer situated on a cradle directly attached to a rotational sensor. However, due to system tolerances, axis of probe does not align exactly with the designed axis of rotation resulting in artifacts in the 3D reconstructed ultrasound volume. We present a rigid registration based automatic probe calibration approach. The method uses a sequence of phantom images, each pair acquired at angular separation of 180 degrees and registers corresponding image pairs to compute the deviation from designed axis. A modified shadow removal algorithm is applied for preprocessing. An attribute vector is constructed from image intensity and a speckle-insensitive information-theoretic feature. We compare registration between the presented method and expert-corrected images in 16 prostate phantom scans. Images were acquired at multiple resolutions, and different misalignment settings from two ultrasound machines. Screenshots from 3D reconstruction are shown before and after misalignment correction. Registration parameters from automatic and manual correction were found to be in good agreement. Average absolute differences of translation and rotation between automatic and manual methods were 0.27 mm and 0.65 degree, respectively. The registration parameters also showed lower variability for automatic registration (pooled standard deviation σtranslation = 0.50 mm, σrotation = 0.52 degree) compared to the manual approach (pooled standard deviation σtranslation = 0.62 mm, σrotation = 0.78 degree).
Validation of ozone intensities at 10 μm with THz spectrometry
NASA Astrophysics Data System (ADS)
Drouin, Brian J.; Crawford, Timothy J.; Yu, Shanshan
2017-12-01
This manuscript reports an effort to improve the absolute accuracy of ozone intensities in the 10 μm region via a transfer of the precision of the rotational dipole moment onto the infrared measurement. The approach determines the ozone mixing ratio through alternately measuring seven pure rotation ozone lines from 692 to 779 GHz. A multispectrum fitting technique was employed. The results determine the column with absolute accuracy of 1.5% and the intensities of infrared transitions measured at this accuracy reproduce the recommended values to within a standard deviation of 2.8%.
40 CFR 62.14740 - What must I include in the deviation report?
Code of Federal Regulations, 2010 CFR
2010-07-01
... your unit deviated from the emission limitations or operating limit requirements. (b) The averaged and recorded data for those dates. (c) Duration and causes of each deviation from the emission limitations or... that deviated from the emission limitations or operating limits specified in this subpart, include the...
Evaluation of Piecewise Polynomial Equations for Two Types of Thermocouples
Chen, Andrew; Chen, Chiachung
2013-01-01
Thermocouples are the most frequently used sensors for temperature measurement because of their wide applicability, long-term stability and high reliability. However, one of the major utilization problems is the linearization of the transfer relation between temperature and output voltage of thermocouples. The linear calibration equation and its modules could be improved by using regression analysis to help solve this problem. In this study, two types of thermocouple and five temperature ranges were selected to evaluate the fitting agreement of different-order polynomial equations. Two quantitative criteria, the average of the absolute error values |e|ave and the standard deviation of calibration equation estd, were used to evaluate the accuracy and precision of these calibrations equations. The optimal order of polynomial equations differed with the temperature range. The accuracy and precision of the calibration equation could be improved significantly with an adequate higher degree polynomial equation. The technique could be applied with hardware modules to serve as an intelligent sensor for temperature measurement. PMID:24351627
NASA Astrophysics Data System (ADS)
Liu, Yang; Yang, Linghui; Guo, Yin; Lin, Jiarui; Cui, Pengfei; Zhu, Jigui
2018-02-01
An interferometer technique based on temporal coherence function of femtosecond pulses is demonstrated for practical distance measurement. Here, the pulse-to-pulse alignment is analyzed for large delay distance measurement. Firstly, a temporal coherence function model between two femtosecond pulses is developed in the time domain for the dispersive unbalanced Michelson interferometer. Then, according to this model, the fringes analysis and the envelope extraction process are discussed. Meanwhile, optimization methods of pulse-to-pulse alignment for practical long distance measurement are presented. The order of the curve fitting and the selection of points for envelope extraction are analyzed. Furthermore, an averaging method based on the symmetry of the coherence function is demonstrated. Finally, the performance of the proposed methods is evaluated in the absolute distance measurement of 20 μ m with path length difference of 9 m. The improvement of standard deviation in experimental results shows that these approaches have the potential for practical distance measurement.
Accuracy assessment of TanDEM-X IDEM using airborne LiDAR on the area of Poland
NASA Astrophysics Data System (ADS)
Woroszkiewicz, Małgorzata; Ewiak, Ireneusz; Lulkowska, Paulina
2017-06-01
The TerraSAR-X add-on for Digital Elevation Measurement (TanDEM-X) mission launched in 2010 is another programme - after the Shuttle Radar Topography Mission (SRTM) in 2000 - that uses space-borne radar interferometry to build a global digital surface model. This article presents the accuracy assessment of the TanDEM-X intermediate Digital Elevation Model (IDEM) provided by the German Aerospace Center (DLR) under the project "Accuracy assessment of a Digital Elevation Model based on TanDEM-X data" for the southwestern territory of Poland. The study area included: open terrain, urban terrain and forested terrain. Based on a set of 17,498 reference points acquired by airborne laser scanning, the mean errors of average heights and standard deviations were calculated for areas with a terrain slope below 2 degrees, between 2 and 6 degrees and above 6 degrees. The absolute accuracy of the IDEM data for the analysed area, expressed as a root mean square error (Total RMSE), was 0.77 m.
Heart rate prediction for coronary artery disease patients (CAD): Results of a clinical pilot study.
Müller-von Aschwege, Frerk; Workowski, Anke; Willemsen, Detlev; Müller, Sebastian M; Hein, Andreas
2015-01-01
This paper describes the results of a pilot study with cardiac patients based on information that can be derived from a smartphone. The idea behind the study is to design a model for estimating the heart rate of a patient before an outdoor walking session for track planning, as well as using the model for guidance during an outdoor session. The model allows estimation of the heart rate several minutes in advance to guide the patient and avoid overstrain before its occurrence. This paper describes the first results of the clinical pilot study with cardiac patients taking β-blockers. 9 patients have been tested on a treadmill and during three outdoor sessions each. The results have been derived and three levels of improvement have been tested by cross validation. The overall result is an average Median Absolute Deviation (MAD) of 4.26 BPM between measured heart rate and smartphone sensor based model estimation.
Densities of aqueous blended amines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, C.H.; Li, M.H.
1997-05-01
Solutions of alkanolamines are an industrially important class of compounds used in the natural gas and synthetic ammonia industries and petroleum chemical plants for the removal of CO{sub 2} and H{sub 2}S from gas streams. The densities of aqueous mixtures of diethanolamine (DEA) + N-methyldiethanolamine (MDEA) + water, DEA + 2-amino-2-methyl-1-propanol (AMP) + water, and monoethanolamine (MEA) + 2-piperidineethanol (2-PE) + water were measured from 30 C to 80 C. A Redlich-Kister equation of the excess volume was applied to represent the density. Based on the available density data for five ternary systems: MEA + MDEA + H{sub 2}O, MEAmore » + AMP + H{sub 2}O, DEA + MDEA + H{sub 2}O, DEA + AMP + H{sub 2}O, and MEA + 2-PE + H{sub 2}O, a generalized set of binary parameters were determined. The density calculations show quite satisfactory results. The overall average absolute percent deviation is about 0.04% for a total of 686 data points.« less
Viscosity Measurements of Ethyl Fluoride (R161) from 243 K to 363 K at Pressures up to 30 MPa
NASA Astrophysics Data System (ADS)
Meng, Xianyang; Gu, Xiaoyun; Wu, Jiangtao; Bi, Shengshan
2015-11-01
The Montreal Protocol and its subsequent amendments have created a schedule to replace ozone depletion substances, such as chlorofluorocarbons and hydrochlorofluorocarbons, with chlorine-free molecules in several industrial applications. Ethyl fluoride (R161, C2H5F, 353-36-6) was found to be a potential alternative refrigerant for the replacement of controlled substances, such as R22 with excellent cycle performance. In this work, the viscosity of ethyl fluoride is reported at temperatures from 243 K to 363 K and at pressures from saturation pressure to 30 MPa. The experiment was performed with a calibrated vibrating-wire viscometer, which exhibited a combined expanded uncertainty of 2.5 % with a level of confidence of 0.95 (k = 2) for such a fluid. A scheme based on a hard-spheres model was used to correlate the experimental results. The average absolute deviation of the experimental results from the correlations for R161 is 0.88 %.
Investigations on 3-dimensional temperature distribution in a FLATCON-type CPV module
NASA Astrophysics Data System (ADS)
Wiesenfarth, Maike; Gamisch, Sebastian; Kraus, Harald; Bett, Andreas W.
2013-09-01
The thermal flow in a FLATCON®-type CPV module is investigated theoretically and experimentally. For the simulation a model in the computational fluid dynamics (CFD) software SolidWorks Flow Simulation was established. In order to verify the simulation results the calculated and measured temperatures were compared assuming the same operating conditions (wind speed and direction, direct normal irradiance (DNI) and ambient temperature). Therefore, an experimental module was manufactured and equipped with temperature sensors at defined positions. In addition, the temperature distribution on the back plate of the module was displayed by infrared images. The simulated absolute temperature and the distribution compare well with an average deviation of only 3.3 K to the sensor measurements. Finally, the validated model was used to investigate the influence of the back plate material on the temperature distribution by replacing the glass material by aluminum. The simulation showed that it is important to consider heat dissipation by radiation when designing a CPV module.
NASA Astrophysics Data System (ADS)
Hamzehlouia, Sepehr; Asfour, Abdul-Fattah A.
2013-06-01
The volumetric and viscometric properties of the quinary system: cyclohexane + m -xylene + cyclooctane + chlorobenzene + decane, were measured over the entire composition range at 308.15 K and 313.15 K. The experimental data obtained in the course of the present study were employed to analyze the predictive capability of six semi-theoretical and empirical well-known viscosity models reported in the literature, namely, the generalized McAllister three-body interaction model, the pseudo- binary McAllister model, the group contribution model, the generalized corresponding states principle model, the Allan and Teja correlation, and the Grunberg and Nissan law of viscosity. The predictive capabilities of the models were compared using the percentage average absolute deviation (%AAD). The final results showed that the generalized McAllister model gives the lowest AADs of 3.3 % and 3.7 % at 308.15 K and 313.15 K, respectively.
Malekzadeh, Mohammad; Abedini Najafabadi, Hamed; Hakim, Maziar; Feilizadeh, Mehrzad; Vossoughi, Manouchehr; Rashtchian, Davood
2016-02-01
In this research, organic solvent composed of hexane and methanol was used for lipid extraction from dry and wet biomass of Chlorella vulgaris. The results indicated that lipid and fatty acid extraction yield was decreased by increasing the moisture content of biomass. However, the maximum extraction efficiency was attained by applying equivolume mixture of hexane and methanol for both dry and wet biomass. Thermodynamic modeling was employed to estimate the effect of hexane/methanol ratio and moisture content on fatty acid extraction yield. Hansen solubility parameter was used in adjusting the interaction parameters of the model, which led to decrease the number of tuning parameters from 6 to 2. The results indicated that the model can accurately estimate the fatty acid recovery with average absolute deviation percentage (AAD%) of 13.90% and 15.00% for the two cases of using 6 and 2 adjustable parameters, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.
Human Age Recognition by Electrocardiogram Signal Based on Artificial Neural Network
NASA Astrophysics Data System (ADS)
Dasgupta, Hirak
2016-12-01
The objective of this work is to make a neural network function approximation model to detect human age from the electrocardiogram (ECG) signal. The input vectors of the neural network are the Katz fractal dimension of the ECG signal, frequencies in the QRS complex, male or female (represented by numeric constant) and the average of successive R-R peak distance of a particular ECG signal. The QRS complex has been detected by short time Fourier transform algorithm. The successive R peak has been detected by, first cutting the signal into periods by auto-correlation method and then finding the absolute of the highest point in each period. The neural network used in this problem consists of two layers, with Sigmoid neuron in the input and linear neuron in the output layer. The result shows the mean of errors as -0.49, 1.03, 0.79 years and the standard deviation of errors as 1.81, 1.77, 2.70 years during training, cross validation and testing with unknown data sets, respectively.
Delmonico, Matthew J; Kostek, Matthew C; Doldo, Neil A; Hand, Brian D; Walsh, Sean; Conway, Joan M; Carignan, Craig R; Roth, Stephen M; Hurley, Ben F
2007-02-01
The alpha-actinin-3 (ACTN3) R577X polymorphism has been associated with muscle power performance in cross-sectional studies. We examined baseline knee extensor concentric peak power (PP) and PP change with approximately 10 weeks of unilateral knee extensor strength training (ST) using air-powered resistance machines in 71 older men (65 [standard deviation = 8] years) and 86 older women (64 [standard deviation = 9] years). At baseline in women, the XX genotype group had an absolute (same resistance) PP that was higher than the RR (p =.005) and RX genotype groups (p =.02). The women XX group also had a relative (70% of one-repetition maximum [1-RM]) PP that was higher than that in the RR (p =.002) and RX groups (p =.008). No differences in baseline absolute or relative PP were observed between ACTN3 genotype groups in men. In men, absolute PP change with ST in the RR (n = 16) group approached a significantly higher value than in the XX group (n = 9; p =.07). In women, relative PP change with ST in the RR group (n = 16) was higher than in the XX group (n = 17; p =.02). The results indicate that the ACTN3 R577X polymorphism influences the response of quadriceps muscle power to ST in older adults.
Predictive model for disinfection by-product in Alexandria drinking water, northern west of Egypt.
Abdullah, Ali M; Hussona, Salah El-dien
2013-10-01
Chlorine has been utilized in the early stages of water treatment processes as disinfectant. Disinfection for drinking water reduces the risk of pathogenic infection but may pose a chemical threat to human health due to disinfection residues and their by-products (DBP) when the organic and inorganic precursors are present in water. In the last two decades, many modeling attempts have been made to predict the occurrence of DBP in drinking water. Models have been developed based on data generated in laboratory-scale and field-scale investigations. The objective of this paper is to develop a predictive model for DBP formation in the Alexandria governorate located at the northern west of Egypt based on field-scale investigations as well as laboratory-controlled experimentations. The present study showed that the correlation coefficient between trihalomethanes (THM) predicted and THM measured was R (2)=0.88 and the minimum deviation percentage between THM predicted and THM measured was 0.8 %, the maximum deviation percentage was 89.3 %, and the average deviation was 17.8 %, while the correlation coefficient between dichloroacetic acid (DCAA) predicted and DCAA measured was R (2)=0.98 and the minimum deviation percentage between DCAA predicted and DCAA measured was 1.3 %, the maximum deviation percentage was 47.2 %, and the average deviation was 16.6 %. In addition, the correlation coefficient between trichloroacetic acid (TCAA) predicted and TCAA measured was R (2)=0.98 and the minimum deviation percentage between TCAA predicted and TCAA measured was 4.9 %, the maximum deviation percentage was 43.0 %, and the average deviation was 16.0 %.
Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B
2017-10-01
In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P < .0018). The exploratory analysis revealed no significant difference in the standard deviations of the log proportional errors for injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.
Hahn, David K; RaghuVeer, Krishans; Ortiz, J V
2014-05-15
Time-dependent density functional theory (TD-DFT) and electron propagator theory (EPT) are used to calculate the electronic transition energies and ionization energies, respectively, of species containing phosphorus or sulfur. The accuracy of TD-DFT and EPT, in conjunction with various basis sets, is assessed with data from gas-phase spectroscopy. TD-DFT is tested using 11 prominent exchange-correlation functionals on a set of 37 vertical and 19 adiabatic transitions. For vertical transitions, TD-CAM-B3LYP calculations performed with the MG3S basis set are lowest in overall error, having a mean absolute deviation from experiment of 0.22 eV, or 0.23 eV over valence transitions and 0.21 eV over Rydberg transitions. Using a larger basis set, aug-pc3, improves accuracy over the valence transitions via hybrid functionals, but improved accuracy over the Rydberg transitions is only obtained via the BMK functional. For adiabatic transitions, all hybrid functionals paired with the MG3S basis set perform well, and B98 is best, with a mean absolute deviation from experiment of 0.09 eV. The testing of EPT used the Outer Valence Green's Function (OVGF) approximation and the Partial Third Order (P3) approximation on 37 vertical first ionization energies. It is found that OVGF outperforms P3 when basis sets of at least triple-ζ quality in the polarization functions are used. The largest basis set used in this study, aug-pc3, obtained the best mean absolute error from both methods -0.08 eV for OVGF and 0.18 eV for P3. The OVGF/6-31+G(2df,p) level of theory is particularly cost-effective, yielding a mean absolute error of 0.11 eV.
A Simple Model Predicting Individual Weight Change in Humans
Thomas, Diana M.; Martin, Corby K.; Heymsfield, Steven; Redman, Leanne M.; Schoeller, Dale A.; Levine, James A.
2010-01-01
Excessive weight in adults is a national concern with over 2/3 of the US population deemed overweight. Because being overweight has been correlated to numerous diseases such as heart disease and type 2 diabetes, there is a need to understand mechanisms and predict outcomes of weight change and weight maintenance. A simple mathematical model that accurately predicts individual weight change offers opportunities to understand how individuals lose and gain weight and can be used to foster patient adherence to diets in clinical settings. For this purpose, we developed a one dimensional differential equation model of weight change based on the energy balance equation is paired to an algebraic relationship between fat free mass and fat mass derived from a large nationally representative sample of recently released data collected by the Centers for Disease Control. We validate the model's ability to predict individual participants’ weight change by comparing model estimates of final weight data from two recent underfeeding studies and one overfeeding study. Mean absolute error and standard deviation between model predictions and observed measurements of final weights are less than 1.8 ± 1.3 kg for the underfeeding studies and 2.5 ± 1.6 kg for the overfeeding study. Comparison of the model predictions to other one dimensional models of weight change shows improvement in mean absolute error, standard deviation of mean absolute error, and group mean predictions. The maximum absolute individual error decreased by approximately 60% substantiating reliability in individual weight change predictions. The model provides a viable method for estimating individual weight change as a result of changes in intake and determining individual dietary adherence during weight change studies. PMID:24707319
Qualification of a Quantitative Laryngeal Imaging System Using Videostroboscopy and Videokymography
Popolo, Peter S.; Titze, Ingo R.
2008-01-01
Objectives: We sought to determine whether full-cycle glottal width measurements could be obtained with a quantitative laryngeal imaging system using videostroboscopy, and whether glottal width and vocal fold length measurements were repeatable and reliable. Methods: Synthetic vocal folds were phonated on a laboratory bench, and dynamic images were obtained in repeated trials by use of videostroboscopy and videokymography (VKG) with an imaging system equipped with a 2-point laser projection device for measuring absolute dimensions. Video images were also obtained with an industrial videoscope system with a built-in laser measurement capability. Maximum glottal width and vocal fold length were compared among these 3 methods. Results: The average variation in maximum glottal width measurements between stroboscopic data and VKG data was 3.10%. The average variations in width measurements between the clinical system and the industrial system were 1.93% (stroboscopy) and 3.49% (VKG). The variations in vocal fold length were similarly small. The standard deviations across trials were 0.29 mm for width and 0.48 mm for length (stroboscopy), 0.18 mm for width (VKG), and 0.25 mm for width and 0.84 mm for length (industrial). Conclusions: For stable, periodic vibration, the full extent of the glottal width can be reliably measured with the quantitative videostroboscopy system. PMID:18646436
Seismic Anisotropy Beneath Eastern North America: Results from Multi-Event Inversion
NASA Astrophysics Data System (ADS)
Li, Y.; Levin, V. L.; Chen, X.
2017-12-01
Seismic anisotropy observed from the split core-refracted shear phases reflects upper mantle deformation. To characterize anisotropic signatures beneath eastern North America, we collected observations along a 1300 km long array from James Bay to the Fundy Basin. The averaged splitting parameters of individual sites show uniform fast polarization orientation of 80° and delay times linearly decreasing from 1.0 s in the Appalachians to 0.5 s in the Superior Province. We also see directional variation of fast polarizations at most sites, which is a likely effect of vertical changes in anisotropic properties. For sites with 10 or more observations, we used a multi-event inversion technique to solve for the underlying anisotropic structure. The technique considers the NULL observations from single-event analysis that are excluded from the averaged splitting parameters. For models with a single 100 km thick anisotropic layer with a horizontal fast axis, we find up to 6% of anisotropy in the Appalachian Orogen, equivalent to a splitting delay time of 1.5 s. Anisotropy strength reduces to 1.8% in the Superior Province, equivalent to delay times under 0.5 s. The overall decrease in anisotropic strength is modified by local changes of up to 2%, suggesting small-scale local variations near the surface. Orientations of the fast axes change from 60° in the Appalachian Orogen to 90° in the Superior Province, and are also modulated by local deviations. In the Appalachian Orogen the fast axes are close to the absolute plate motion in a hot-spot reference frame, while those in the Superior Province differ from it by almost 30°. Average values of splitting delays agree well with results of inversions in the Superior Province, and diverge in the Appalachians. Conversely, averaged fast polarizations match inversion results in the Appalachians, and are systematically different in the Superior Province. For an set of sites with recording periods exceeding 5 years, we will test more complicated models of anisotropy, including dipping fast axes and multiple layers. Figure 1. The best fit anisotropic parameters, orientations of fast axes (top) and strength of anisotropy (bottom), assuming a single 100 km thick horizontal layer with a horizontal fast axis. The red line in top represents the absolute plate motion in a hot spot reference frame.
ESTIMATION OF RADIOACTIVE CALCIUM-45 BY LIQUID SCINTILLATION COUNTING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lutwak, L.
1959-03-01
A liquid sclntillation counting method is developed for determining radioactive calcium-45 in biological materials. The calcium-45 is extracted, concentrated, and dissolved in absolute ethyl alcohol to which is added 0.4% diphenyloxazol in toluene. Counting efficiency is about 65 percent with standard deviation of the J-57 engin 7.36 percent. (auth)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santoro, J. P.; McNamara, J.; Yorke, E.
2012-10-15
Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged imagesmore » for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction, seven required a single correction, one required two corrections, and one required three corrections. Mean residual GTV deviation (3D distance) following GTV-based systematic correction (mean {+-} 1 standard deviation 4.8 {+-} 1.5 mm) is significantly lower than for systematic skeletal-based (6.5 {+-} 2.9 mm, p= 0.015), and weekly skeletal-based correction (7.2 {+-} 3.0 mm, p= 0.001), but is not significantly lower than daily skeletal-based correction (5.4 {+-} 2.6 mm, p= 0.34). In two cases, first-day CBCT images reveal tumor changes-one showing tumor growth, the other showing large tumor displacement-that are not readily observed in radiographs. Differences in computed GTV deviations between respiration-correlated and respiration-averaged images are 0.2 {+-} 1.8 mm in the superior-inferior direction and are of similar magnitude in the other directions. Conclusions: An off-line protocol to correct GTV-based systematic error in locally advanced lung tumor cases can be effective at reducing tumor deviations, although the findings need confirmation with larger patient statistics. In some cases, a single cone-beam CT can be useful for assessing tumor changes early in treatment, if more than a few days elapse between simulation and the start of treatment. Tumor deviations measured with respiration-averaged CT and CBCT images are consistent with those measured with respiration-correlated images; the respiration-averaged method is more easily implemented in the clinic.« less
Yang, Shuai; Liu, Ying
2018-08-01
Liquid crystal nematic elastomers are one kind of smart anisotropic and viscoelastic solids simultaneously combing the properties of rubber and liquid crystals, which is thermal sensitivity. In this paper, the wave dispersion in a liquid crystal nematic elastomer porous phononic crystal subjected to an external thermal stimulus is theoretically investigated. Firstly, an energy function is proposed to determine thermo-induced deformation in NE periodic structures. Based on this function, thermo-induced band variation in liquid crystal nematic elastomer porous phononic crystals is investigated in detail. The results show that when liquid crystal elastomer changes from nematic state to isotropic state due to the variation of the temperature, the absolute band gaps at different bands are opened or closed. There exists a threshold temperature above which the absolute band gaps are opened or closed. Larger porosity benefits the opening of the absolute band gaps. The deviation of director from the structural symmetry axis is advantageous for the absolute band gap opening in nematic state whist constrains the absolute band gap opening in isotropic state. The combination effect of temperature and director orientation provides an added degree of freedom in the intelligent tuning of the absolute band gaps in phononic crystals. Copyright © 2018 Elsevier B.V. All rights reserved.
Cruise Summary of WHP P6, A10, I3 and I4 Revisits in 2003
NASA Astrophysics Data System (ADS)
Kawano, T.; Uchida, H.; Schneider, W.; Kumamoto, Y.; Nishina, A.; Aoyama, M.; Murata, A.; Sasaki, K.; Yoshikawa, Y.; Watanabe, S.; Fukasawa, M.
2004-12-01
Japan Agency for Marin-Earth Science and Technology (JAMSTEC) conducted a research cruise to round in the southern hemisphere by R/V Mirai. In this presentation, we introduce an outline of the cruise and data quality obtained during the cruise. The cruise started on Aug. 3, 2003 in Brisbane, Australia and sailed eastward until it reached Fremantle, Australia on Feb. 19, 2004. It contained six legs and legs 1, 2, 4 and 5 were revisits of WOCE Hydrographic Program (WHP) sections P6W, P6E, A10 and I3/I4, respectively. The sections consisted of about 500 hydrographic stations in total. On each station, CTD profiles and up to 36 water samples by 12L Niskin-X bottles were taken from the surface to within 10 m of the bottom. Water samples were analyzed at every station for salinity, dissolved oxygen (DO), and nutrients and at alternate stations for concentration of freons, dissolved inorganic carbon (CT), total alkalinity (AT), pH, and so on. Approximately 17,000 samples were obtained for salinity. The standard seawater was measured repeatedly to estimate the uncertainty caused by the setting and stability of the salinometer. The standard deviation of 699 repeated runs of standard seawater was 0.0002 in salinity. Replicate samples, which are a pair of samples drawn from the same Niskin bottle to different sample bottles, were taken to evaluate the overall uncertainty. The standard deviation of absolute differences of 2,769 replicates was also 0.0002 in salinity. For DO, about 13,400 samples were obtained. The analysis was made by a photometric titration technique. The reproducibility estimated from the absolute standard deviation of 1,625 replicates was about 0.09 umol/kg. CTD temperature was calibrated against a deep ocean standards thermometer (SBE35) which was attached to the CTD using a polynomial expression Tcal = T - (a +b*P + c*t), where Tcal is calibrated temperature, T is CTD temperature, P is CTD pressure and t is time. Calibration coefficients, a, b and c, were determined for each station by minimizing the sum of absolute deviation from SBE35 temperature below 2,000dbar. CTD salinity and DO were fitted to values obtained by sampled water analysis using similar polynomials. These corrections yielded deviations of about 0.0002 K in temperature, 0.0003 in salinity and 0.6 umol/kg in DO. Nutrients analyses were accomplished on 16,000 samples using the reference material of nutrients in seawater (RMNS). To establish the traceability and to get higher quality data, 500 bottles of RMNS from the same lot and 150 sets of RMNSs were used. The precisions of phosphate, nitrate and silicate measurements were 0.18 %, 0.17 % and 0.16 % in terms of median of those at 493 stations, respectively. The nutrients concentrations could be expressed with uncertainties explicitly because of the repeated runs of RMNSs. All the analyses for the CO{2}-system parameters in water columns were finished onboard. Analytical precisions of CT, AT and pH were estimated to be \\sim1.0 umol/kg, \\sim2.0 umol/kg, and \\sim7*10-4 pH unit, respectively. Approximately 6,300 samples were obtained for CFC-11 and CFC-12. The concentrations were determined with an electron capture detector - gas chromatograph (ECD-GC) attached the purge and trapping system. The reproducibility estimated from the absolute standard deviation of 365 replicates was less than 1% with respect to the surface concentrations.
Mirzaeinia, Ali; Feyzi, Farzaneh; Hashemianzadeh, Seyed Majid
2017-12-07
Simple and accurate expressions are presented for the equation of state (EOS) and absolute Helmholtz free energy of a system composed of simple atomic particles interacting through the repulsive Lennard-Jones potential model in the fluid and solid phases. The introduced EOS has 17 and 22 coefficients for fluid and solid phases, respectively, which are regressed to the Monte Carlo (MC) simulation data over the reduced temperature range of 0.6≤T * ≤6.0 and the packing fraction range of 0.1 ≤ η ≤ 0.72. The average absolute relative percent deviation in fitting the EOS parameters to the MC data is 0.06 and 0.14 for the fluid and solid phases, respectively. The thermodynamic integration method is used to calculate the free energy using the MC simulation results. The Helmholtz free energy of the ideal gas is employed as the reference state for the fluid phase. For the solid phase, the values of the free energy at the reduced density equivalent to the close-packed of a hard sphere are used as the reference state. To check the validity of the predicted values of the Helmholtz free energy, the Widom particle insertion method and the Einstein crystal technique of Frenkel and Ladd are employed. The results obtained from the MC simulation approaches are well agreed to the EOS results, which show that the proposed model can reliably be utilized in the framework of thermodynamic theories.
In-vivo studies of reflectance pulse oximeter sensor
NASA Astrophysics Data System (ADS)
Ling, Jian; Takatani, Setsuo; Noon, George P.; Nose, Yukihiko
1993-08-01
Reflectance oximetry can offer an advantage of being applicable to any portion of the body. However, the major problem of reflectance oximetry is low pulsatile signal level which prevents prolonged clinical application during extreme situations, such as hypothermia and vasoconstriction. In order to improve the pulsatile signal level of reflectance pulse oximeter and thus its accuracy, three different sensors, with the separation distances (SPD) between light emitting diode (LED) and photodiode being 3, 5, and 7 mm respectively, were studied on nine healthy volunteers. With the increase of the SPD, it was found that both the red (660 nm) and near-infrared (830 nm) pulsatile to average signal ratio (AC/DC) increased, and the standard deviations of (AC/DC)red/(AC/DC)infrared ratio decreased, in spite of the decrease of the absolute signal level. Further clinical studies of 3 mm and 7 mm SPD sensors on seven patients also showed that the (AC/DC)red/(AC/DC)infrared ratio measured by the 7 mm sensor were less disturbed than the 3 mm sensor during the surgery. A theoretical study based on the three-dimensional photon diffusion theory supports the experimental and clinical results. As a conclusion, the 7 mm sensor has the highest signal-to- noise ratio among three different sensors. A new 7 mm SPD reflectance sensor, with the increased number of LEDs around the photodiode, was designed to increase the AC/DC ratio, as well as to increase the absolute signal level.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cherpak, Amanda
Purpose: The Octavius 1000{sup SRS} detector was commissioned in December 2014 and is used routinely for verification of all SRS and SBRT plans. Results of verifications were analyzed to assess trends and limitations of the device and planning methods. Methods: Plans were delivered using a True Beam STx and results were evaluated using gamma analysis (95%, 3%/3mm) and absolute dose difference (5%). Verification results were analyzed based on several plan parameters including tumour volume, degree of modulation and prescribed dose. Results: During a 12 month period, a total of 124 patient plans were verified using the Octavius detector. Thirteen plansmore » failed the gamma criteria, while 7 plans failed based on the absolute dose difference. When binned according to degree of modulation, a significant correlation was found between MU/cGy and both mean dose difference (r=0.78, p<0.05) and gamma (r=−0.60, p<0.05). When data was binned according to tumour volume, the standard deviation of average gamma dropped from 2.2% – 3.7% for the volumes less than 30 cm{sup 3} to below 1% for volumes greater than 30 cm{sup 3}. Conclusions: The majority of plans and verification failures involved tumour volumes smaller than 30 cm{sup 3}. This was expected due to the nature of disease treated with SBRT and SRS techniques and did not increase rate of failure. Correlations found with MU/cGy indicate that as modulation increased, results deteriorated but not beyond the previously set thresholds.« less
NASA Astrophysics Data System (ADS)
Mirzaeinia, Ali; Feyzi, Farzaneh; Hashemianzadeh, Seyed Majid
2017-12-01
Simple and accurate expressions are presented for the equation of state (EOS) and absolute Helmholtz free energy of a system composed of simple atomic particles interacting through the repulsive Lennard-Jones potential model in the fluid and solid phases. The introduced EOS has 17 and 22 coefficients for fluid and solid phases, respectively, which are regressed to the Monte Carlo (MC) simulation data over the reduced temperature range of 0.6 ≤T*≤6.0 and the packing fraction range of 0.1 ≤ η ≤ 0.72. The average absolute relative percent deviation in fitting the EOS parameters to the MC data is 0.06 and 0.14 for the fluid and solid phases, respectively. The thermodynamic integration method is used to calculate the free energy using the MC simulation results. The Helmholtz free energy of the ideal gas is employed as the reference state for the fluid phase. For the solid phase, the values of the free energy at the reduced density equivalent to the close-packed of a hard sphere are used as the reference state. To check the validity of the predicted values of the Helmholtz free energy, the Widom particle insertion method and the Einstein crystal technique of Frenkel and Ladd are employed. The results obtained from the MC simulation approaches are well agreed to the EOS results, which show that the proposed model can reliably be utilized in the framework of thermodynamic theories.
Deviation Value for Conventional X-ray in Hospitals in South Sulawesi Province from 2014 to 2016
NASA Astrophysics Data System (ADS)
Bachtiar, Ilham; Abdullah, Bualkar; Tahir, Dahlan
2018-03-01
This paper describes the conventional X-ray machine parameters tested in the region of South Sulawesi from 2014 to 2016. The objective of this research is to know deviation of every parameter of conventional X-ray machine. The testing parameters were analyzed by using quantitative methods with participatory observational approach. Data collection was performed by testing the output of conventional X-ray plane using non-invasive x-ray multimeter. The test parameters include tube voltage (kV) accuracy, radiation output linearity, reproducibility and radiation beam value (HVL) quality. The results of the analysis show four conventional X-ray test parameters have varying deviation spans, where the tube voltage (kV) accuracy has an average value of 4.12%, the average radiation output linearity is 4.47% of the average reproducibility of 0.62% and the averaged of the radiation beam (HVL) is 3.00 mm.
NASA Astrophysics Data System (ADS)
Taylor, Decarlos E.; Sausa, Rosario C.
2018-06-01
The determination of crystal structures plays an important role for model testing and validation, and understanding intra and intermolecular interactions that influence crystal packing. Here, we report the molecular structure of two recently synthesized energetic molecules, 3,3-bis-isoxazole-5,5‧-bis-methylene dinitrate (C8H6N4O8, BIDN) and bis-isoxazole tetramethylene tetranitrate (C10H8N6O14, BITN) determined by single crystal x-ray diffraction and solid state density functional theory (DFT). BIDN is composed of two planar alkyl nitrate groups (r.m.s deviation = 0.0004 (1) Å) bonded to two planar azole rings (r.m.s deviation = 0.001 (1) Å, whereas BITN is composed of four planar alkyl nitrate groups (average r.m.s deviation = 0.002 (1) Å) bonded to two planar azole rings (average r.m.s deviation = 0.002 (1) Å). The theoretical calculations predict very well the planarity of both the alkyl nitrate groups and rings for both compounds. Furthermore, they predict well the bond lengths and angles of both molecules with mean deviation values of 0.018 Å (BIDN) and 0.017 Å (BITN) and 0.481° (BIDN) and 0.747° (BITN). Overall, the DFT determined torsion angles agree well with those determined experimentally for both BIDN (average deviation = 1.139°) and BITN (average deviation = 0.604°). The theoretical cell constant values are in excellent agreement with those determined experimentally for both molecules, with the BIDN a cell value and β angle showing the largest deviation, 2.1% and -1.3%, respectively. Contacts between the atoms N and H dominate the intermolecular interactions of BIDN, whereas contacts involving the atoms O and H dominate the BITN intermolecular interactions. Electrostatic potential calculations at the B3LYP/6-31G* level reveal BIDN exhibits a lower sensitivity to impact compared to BITN.
A study on the measurement of wrist motion range using the iPhone 4 gyroscope application.
Kim, Tae Seob; Park, David Dae Hwan; Lee, Young Bae; Han, Dong Gil; Shim, Jeong Su; Lee, Young Jig; Kim, Peter Chan Woo
2014-08-01
Measuring the range of motion (ROM) of the wrist is an important physical examination conducted in the Department of Hand Surgery for the purpose of evaluation, diagnosis, prognosis, and treatment of patients. The most common method for performing this task is by using a universal goniometer. This study was performed using 52 healthy participants to compare wrist ROM measurement using a universal goniometer and the iPhone 4 Gyroscope application. Participants did not have previous wrist illnesses and their measured values for wrist motion were compared in each direction. Normal values for wrist ROM are 73 degrees of flexion, 71 degrees of extension, 19 degrees of radial deviation, 33 degrees of ulnar deviation, 140 degrees of supination, and 60 degrees of pronation.The average measurement values obtained using the goniometer were 74.2 (5.1) degrees for flexion, 71.1 (4.9) degrees for extension, 19.7 (3.0) degrees for radial deviation, 34.0 (3.7) degrees for ulnar deviation, 140.8 (5.6) degrees for supination, and 61.1 (4.7) degrees for pronation. The average measurement values obtained using the iPhone 4 Gyroscope application were 73.7 (5.5) degrees for flexion, 70.8 (5.1) degrees for extension, 19.5 (3.0) degrees for radial deviation, 33.7 (3.9) degrees for ulnar deviation, 140.4 (5.7) degrees for supination, and 60.8 (4.9) degrees for pronation. The differences between the measurement values by the Gyroscope application and average value were 0.7 degrees for flexion, -0.2 degrees for extension, 0.5 degrees for radial deviation, 0.7 degrees for ulnar deviation, 0.4 degrees for supination, and 0.8 degrees for pronation. The differences in average value were not statistically significant. The authors introduced a new method of measuring the range of wrist motion using the iPhone 4 Gyroscope application that is simpler to use and can be performed by the patient outside a clinical setting.
SU-F-T-472: Validation of Absolute Dose Measurements for MR-IGRT With and Without Magnetic Field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Green, O; Li, H; Goddu, S
Purpose: To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. Methods: The standard method (AAPM’s TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 cc) and the PTW (Freiburg, Germany). A previously reported Monte Carlo simulation suggested a difference on the order of 0.5% for dose measured with and without the presence of the magnetic field, but testing this was not possible until anmore » engineering solution to allow the radiation system to be used without the nominal magnetic field was found. A previously identified effect of orientation in the magnetic field was also tested by placing the chamber either parallel or perpendicular to the field and irradiating from two opposing angles (90 and 270). Finally, the Imaging and Radiation Oncology Core provided OSLD detectors for five irradiations each with and without the field - with two heads at both 0 and 90 degrees, and one head at 90 degrees only as it doesn’t reach 0 (IEC convention). Results: For the TG-51 comparison, expected dose was obtained by decaying values measured at the time of source installation. The average measured difference was 0.4%±0.12% for A18 and 0.06%±0.15% for Farmer chamber. There was minimal (0.3%) orientation dependence without the magnetic field for the A18 chamber, while previous measurements with the magnetic field had a deviation of 3.2% with chamber perpendicular to magnetic field. Results reported by IROC for the OSLDs with and without the field had a maximum difference of 2%. Conclusion: Accurate absolute dosimetry was verified by measurement under the same conditions with and without the magnetic field for both ionization chambers and independently-verifiable OSLDs.« less
Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems.
Leelarathna, Lalantha; Nodale, Marianna; Allen, Janet M; Elleri, Daniela; Kumareswaran, Kavita; Haidar, Ahmad; Caldwell, Karen; Wilinska, Malgorzata E; Acerini, Carlo L; Evans, Mark L; Murphy, Helen R; Dunger, David B; Hovorka, Roman
2013-02-01
This study evaluated the accuracy and large inaccuracy of the Freestyle Navigator (FSN) (Abbott Diabetes Care, Alameda, CA) and Dexcom SEVEN PLUS (DSP) (Dexcom, Inc., San Diego, CA) continuous glucose monitoring (CGM) systems during closed-loop studies. Paired CGM and plasma glucose values (7,182 data pairs) were collected, every 15-60 min, from 32 adults (36.2±9.3 years) and 20 adolescents (15.3±1.5 years) with type 1 diabetes who participated in closed-loop studies. Levels 1, 2, and 3 of large sensor error with increasing severity were defined according to absolute relative deviation greater than or equal to ±40%, ±50%, and ±60% at a reference glucose level of ≥6 mmol/L or absolute deviation greater than or equal to ±2.4 mmol/L,±3.0 mmol/L, and ±3.6 mmol/L at a reference glucose level of <6 mmol/L. Median absolute relative deviation was 9.9% for FSN and 12.6% for DSP. Proportions of data points in Zones A and B of Clarke error grid analysis were similar (96.4% for FSN vs. 97.8% for DSP). Large sensor over-reading, which increases risk of insulin over-delivery and hypoglycemia, occurred two- to threefold more frequently with DSP than FSN (once every 2.5, 4.6, and 10.7 days of FSN use vs. 1.2, 2.0, and 3.7 days of DSP use for Level 1-3 errors, respectively). At levels 2 and 3, large sensor errors lasting 1 h or longer were absent with FSN but persisted with DSP. FSN and DSP differ substantially in the frequency and duration of large inaccuracy despite only modest differences in conventional measures of numerical and clinical accuracy. Further evaluations are required to confirm that FSN is more suitable for integration into closed-loop delivery systems.
Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi
2013-07-01
Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and presented separately for clinically different categories, e.g., hypoglycemia, exercise, or night and day. © 2013 Diabetes Technology Society.
SU-F-T-345: Quasi-Dead Beams: Clinical Relevance and Implications for Automatic Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, R; Veltchev, I; Lin, T
Purpose: Beam direction selection for fixed-beam IMRT planning is typically a manual process. Severe dose-volume limits on critical structures in the thorax often result in atypical selection of beam directions as compared to other body sites. This work demonstrates the potential consequences as well as clinical relevance. Methods: 21 thoracic cases treated with 5–7 beam directions, 6 cases including non-coplanar arrangements, with fractional doses of 150–411cGy were analyzed. Endpoints included per-beam modulation scaling factor (MSF), variation from equal weighting, and delivery QA passing rate. Results: During analysis of patient-specific delivery QA a sub-standard passing rate was found for a singlemore » 5-field plan (90.48% of pixels evaluated passing 3% dose, 3mm DTA). During investigation it was found that a single beam demonstrated a MSF of 34.7 and contributed only 2.7% to the mean dose of the target. In addition, the variation from equal weighting for this beam was 17.3% absolute resulting in another beam with a MSF of 4.6 contributing 41.9% to the mean dose to the target; a variation of 21.9% from equal weighting. The average MSF for the remaining 20 cases was 4.0 (SD 1.8) with an average absolute deviation of 2.8% from equal weighting (SD 3.1%). Conclusion: Optimization in commercial treatment planning systems typically results in relatively equally weighted beams. Extreme variation from this can result in excessively high MSFs (very small segments) and potential decreases in agreement between planned and delivered dose distributions. In addition, the resultant beam may contribute minimal dose to the target (quasi-dead beam); a byproduct being increased treatment time and associated localization uncertainties. Potential ramifications exist for automatic planning algorithms should they allow for user-defined beam directions. Additionally, these quasi-dead beams may be embedded in the libraries for model-based systems potentially resulting in inefficient and less accurate deliveries.« less
SU-F-J-95: Impact of Shape Complexity On the Accuracy of Gradient-Based PET Volume Delineation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dance, M; Wu, G; Gao, Y
2016-06-15
Purpose: Explore correlation of tumor complexity shape with PET target volume accuracy when delineated with gradient-based segmentation tool. Methods: A total of 24 clinically realistic digital PET Monte Carlo (MC) phantoms of NSCLC were used in the study. The phantom simulated 29 thoracic lesions (lung primary and mediastinal lymph nodes) of varying size, shape, location, and {sup 18}F-FDG activity. A program was developed to calculate a curvature vector along the outline and the standard deviation of this vector was used as a metric to quantify a shape’s “complexity score”. This complexity score was calculated for standard geometric shapes and MC-generatedmore » target volumes in PET phantom images. All lesions were contoured using a commercially available gradient-based segmentation tool and the differences in volume from the MC-generated volumes were calculated as the measure of the accuracy of segmentation. Results: The average absolute percent difference in volumes between the MC-volumes and gradient-based volumes was 11% (0.4%–48.4%). The complexity score showed strong correlation with standard geometric shapes. However, no relationship was found between the complexity score and the accuracy of segmentation by gradient-based tool on MC simulated tumors (R{sup 2} = 0.156). When the lesions were grouped into primary lung lesions and mediastinal/mediastinal adjacent lesions, the average absolute percent difference in volumes were 6% and 29%, respectively. The former group is more isolated and the latter is more surround by tissues with relatively high SUV background. Conclusion: The complexity shape of NSCLC lesions has little effect on the accuracy of the gradient-based segmentation method and thus is not a good predictor of uncertainty in target volume delineation. Location of lesion within a relatively high SUV background may play a more significant role in the accuracy of gradient-based segmentation.« less
The truly remarkable universality of half a standard deviation: confirmation through another look.
Norman, Geoffrey R; Sloan, Jeff A; Wyrwich, Kathleen W
2004-10-01
In this issue of Expert Review of Pharmacoeconomics and Outcomes Research, Farivar, Liu, and Hays present their findings in 'Another look at the half standard deviation estimate of the minimally important difference in health-related quality of life scores (hereafter referred to as 'Another look') . These researchers have re-examined the May 2003 Medical Care article 'Interpretation of changes in health-related quality of life: the remarkable universality of half a standard deviation' (hereafter referred to as 'Remarkable') in the hope of supporting their hypothesis that the minimally important difference in health-related quality of life measures is undoubtedly closer to 0.3 standard deviations than 0.5. Nonetheless, despite their extensive wranglings with the exclusion of many articles that we included in our review; the inclusion of articles that we did not include in our review; and the recalculation of effect sizes using the absolute value of the mean differences, in our opinion, the results of the 'Another look' article confirm the same findings in the 'Remarkable' paper.
NASA Astrophysics Data System (ADS)
Yamamoto, Y.; Hoshi, H.
2005-12-01
Correct determination of absolute paleointensities is essential to investigate past geomagnetic field. There are two types of methods to obtain the paleointensities: the Thellier-type and Shaw-type methods. Many paleomagnetists have so far regarded the former method as reliable. However, there are increasing evidences that it is sometimes not robust for basaltic lavas resulting in systematic high paleointensities (e.g. Calvo et al., 2002; Yamamoto et al., 2003). Alternatively, the double heating technique of the Shaw method combined with low temperature demagnetization (LTD-DHT Shaw method; Tsunakawa et al., 1997; Yamamoto et al., 2003), a lately developed paleointensity technique in Japan, can yield reliable answers even from such basaltic samples (e.g. Yamamoto et al., 2003; Mochizuki et al., 2004; Oishi et al., 2005). In the Japanese archipelago, there are not only basaltic lavas but also andesitic lavas. They are important candidates of the absolute paleointensity determination in Japan. For a case study, we sampled oriented paleomagnetic cores from three sites of the Sakurajima 1914 (TS01 and TS02) and 1946 (SW01) lavas in Japan. Several rock magnetic experiments revealed that main magnetic carriers of the present samples are titanomagnetites with Curie temperatures of about 300-550 C, and that high temperature oxidation progresses in the order of SW01, TS01 and TS02. The LTD-DHT Shaw and Coe-Thellier experiments were conducted on 72 and 63 specimens, respectively. They gave 64 and 60 successful determinations. If the results are normalized by expected field intensities calculated from IGRF-9 (Macmillan et al., 2003) and grouped into LTD-DHT Shaw and Thellier datasets, their averages and standard deviations (1 sigma) resulted in 0.98+/-0.11 (LTD-DHT Shaw) and 1.13+/-0.13 (Thellier). Considering the standard deviations, we can say that both paleointensity methods recovered correct geomagnetic field. However, it is apparent that the LTD-DHT Shaw method has higher reliability than the Thellier method.
SU-E-T-188: Commission of World 1st Commercial Compact PBS Proton System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, X; Patel, B; Song, X
2015-06-15
Purpose: ProteusONE is the 1st commercial compact PBS proton system with an upstream scanning gantry and C230 cyclotron. We commissioned XiO and Raystation TPS simultaneously. This is a summary of beam data collection, modeling, and verification and comparison without range shiter for this unique system with both TPS. Methods: Both Raystation and XiO requires the same measurements data: (i) integral depth dose(IDDs) of single central spot measured in water tank; (ii) absolute dose calibration measured at 2cm depth of water with mono-energetic 10×10 cm2 field with spot spacing 4mm, 1MU per spot; and (iii) beam spot characteristics in air atmore » 0cm and ± 20cm away from ISO. To verify the beam model for both TPS, same 15 cube plans were created to simulate different treatment sites, target volumes and positions. PDDs of each plan were measured using a Multi-layer Ionization Chamber(MLIC), absolute point dose verification were measured using PPC05 in water tank and patient-specific QA were measured using MatriXX PT, a 2D ion chamber array. Results: All the point dose measurements at midSOBP were within 2% for both XiO and Raystation. However, up to 5% deviations were observed in XiO’s plans at shallow depth while within 2% in Raystation plans. 100% of the ranges measured were within 1 mm with maximum deviation of 0.5 mm. 20 patient specific plan were generated and measured in 3 planes (distal, proximal and midSOBP) in Raystation. The average of gamma index is 98.7%±3% with minimum 94% Conclusions: Both TPS were successfully commissioned and can be safely deployed for clinical use for ProteusONE. Based on our clinical experience in PBS planning, user interface, function and workflow, we preferably use Raystation as our main clinical TPS. Gamma Index >95% at 3%/3 mm criteria is our institution action level for patient specific plan QAs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoker, J; Summers, P; Li, X
2014-06-01
Purpose: This study seeks to evaluate the dosimetric effects of intra-fraction motion during spot scanning proton beam therapy as a function of beam-scan orientation and target motion amplitude. Method: Multiple 4DCT scans were collected of a dynamic anthropomorphic phantom mimicking respiration amplitudes of 0 (static), 0.5, 1.0, and 1.5 cm. A spot-scanning treatment plan was developed on the maximum intensity projection image set, using an inverse-planning approach. Dynamic phantom motion was continuous throughout treatment plan delivery.The target nodule was designed to accommodate film and thermoluminescent dosimeters (TLD). Film and TLDs were uniquely labeled by location within the target. The phantommore » was localized on the treatment table using the clinically available orthogonal kV on-board imaging device. Film inserts provided data for dose uniformity; TLDs provided a 3% precision estimate of absolute dose. An inhouse script was developed to modify the delivery order of the beam spots, to orient the scanning direction parallel or perpendicular to target motion.TLD detector characterization and analysis was performed by the Imaging and Radiation Oncology Core group (IROC)-Houston. Film inserts, exhibiting a spatial resolution of 1mm, were analyzed to determine dose homogeneity within the radiation target. Results: Parallel scanning and target motions exhibited reduced target dose heterogeneity, relative to perpendicular scanning orientation. The average percent deviation in absolute dose for the motion deliveries relative to the static delivery was 4.9±1.1% for parallel scanning, and 11.7±3.5% (p<<0.05) for perpendicularly oriented scanning. Individual delivery dose deviations were not necessarily correlated to amplitude of motion for either scan orientation. Conclusions: Results demonstrate a quantifiable difference in dose heterogeneity as a function of scan orientation, more so than target amplitude. Comparison to the analyzed planar dose of a single field hint that multiple-field delivery alters intra-fraction beam-target motion synchronization and may mitigate heterogeneity, though further study is warranted.« less
Absolute Parameters for the F-type Eclipsing Binary BW Aquarii
NASA Astrophysics Data System (ADS)
Maxted, P. F. L.
2018-05-01
BW Aqr is a bright eclipsing binary star containing a pair of F7V stars. The absolute parameters of this binary (masses, radii, etc.) are known to good precision so they are often used to test stellar models, particularly in studies of convective overshooting. ... Maxted & Hutcheon (2018) analysed the Kepler K2 data for BW Aqr and noted that it shows variability between the eclipses that may be caused by tidally induced pulsations. ... Table 1 shows the absolute parameters for BW Aqr derived from an improved analysis of the Kepler K2 light curve plus the RV measurements from both Imbert (1979) and Lester & Gies (2018). ... The values in Table 1 with their robust error estimates from the standard deviation of the mean are consistent with the values and errors from Maxted & Hutcheon (2018) based on the PPD calculated using emcee for a fit to the entire K2 light curve.
Measurement of the cosmic microwave background spectrum by the COBE FIRAS instrument
NASA Technical Reports Server (NTRS)
Mather, J. C.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Fixsen, D. J.; Hewagama, T.; Isaacman, R. B.; Jensen, K. A.; Meyer, S. S.; Noerdlinger, P. D.
1994-01-01
The cosmic microwave background radiation (CMBR) has a blackbody spectrum within 3.4 x 10(exp -8) ergs/sq cm/s/sr cm over the frequency range from 2 to 20/cm (5-0.5 mm). These measurements, derived from the Far-Infrared Absolute Spectrophotomer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite, imply stringent limits on energy release in the early universe after t approximately 1 year and redshift z approximately 3 x 10(exp 6). The deviations are less than 0.30% of the peak brightness, with an rms value of 0.01%, and the dimensionless cosmological distortion parameters are limited to the absolute value of y is less than 2.5 x 10(exp -5) and the absolute value of mu is less than 3.3 x 10(exp -4) (95% confidence level). The temperature of the CMBR is 2.726 +/- 0.010 K (95% confidence level systematic).
NASA Astrophysics Data System (ADS)
Olsson, Martin A.; García-Sosa, Alfonso T.; Ryde, Ulf
2018-01-01
We have studied the binding of 102 ligands to the farnesoid X receptor within the D3R Grand Challenge 2016 blind-prediction competition. First, we employed docking with five different docking software and scoring functions. The selected docked poses gave an average root-mean-squared deviation of 4.2 Å. Consensus scoring gave decent results with a Kendall's τ of 0.26 ± 0.06 and a Spearman's ρ of 0.41 ± 0.08. For a subset of 33 ligands, we calculated relative binding free energies with free-energy perturbation. Five transformations between the ligands involved a change of the net charge and we implemented and benchmarked a semi-analytic correction (Rocklin et al., J Chem Phys 139:184103, 2013) for artifacts caused by the periodic boundary conditions and Ewald summation. The results gave a mean absolute deviation of 7.5 kJ/mol compared to the experimental estimates and a correlation coefficient of R 2 = 0.1. These results were among the four best in this competition out of 22 submissions. The charge corrections were significant (7-8 kJ/mol) and always improved the results. By employing 23 intermediate states in the free-energy perturbation, there was a proper overlap between all states and the precision was 0.1-0.7 kJ/mol. However, thermodynamic cycles indicate that the sampling was insufficient in some of the perturbations.
A Comparison of MICROTOPS II and OMI Satellite Ozone Measurements in Novi Sad from 2007 to 2015
NASA Astrophysics Data System (ADS)
Podrascanin, Z.; Balog, I.; Jankovic, A.; Mijatovic, Z.; Nadj, Z.
2017-12-01
In this paper, we present consecutive daily measurements of the total ozone column (TOC) using MICROTOPS II in Novi Sad, the Republic of Serbia (45.3 N, 19.8 E and the altitude of 84 m) from 2007 to 2015. The MICROTOPS II data set was compared to the ozone monitoring instrument (OMI) satellite data, since there was no nearby comparative long-time series available for the Dobson or Brewer instrument. The data quality control of the measured MICROTOPS II TOC data was carried out before the comparison with the satellite data. The MICROTOPS II was calibrated at the manufacturer's facilities and only TOC values drawn from the 305.5/312.5 nm wavelength combination were compared with the satellite data. The mean bias deviation between MICROTOPS II and OMI satellite data sets was obtained to be less than 2%, and the mean absolute deviation was in the range of 5%. The difference in the mean seasonal TOC values in summer and autumn was less than 0.5%, while in winter and spring this difference reached 2.8%. A possible calibration of MICROTOPS II instrument with the satellite data is presented, where the calibration coefficients for all channels were calculated for every satellite and MICROTPS II data pair during one year. Then, the average value of all the calculated coefficients was used for instrument calibration. The presented calibration improves the MICROTOPS II instrument stability and enables the usage of all the wavelength combinations.
ERIC Educational Resources Information Center
Ceulemans, Eva; Van Mechelen, Iven; Leenen, Iwin
2007-01-01
Hierarchical classes models are quasi-order retaining Boolean decomposition models for N-way N-mode binary data. To fit these models to data, rationally started alternating least squares (or, equivalently, alternating least absolute deviations) algorithms have been proposed. Extensive simulation studies showed that these algorithms succeed quite…
40 CFR 1065.1005 - Symbols, abbreviations, acronyms, and units of measure.
Code of Federal Regulations, 2014 CFR
2014-07-01
... of diameters meter per meter m/m 1 b atomic oxygen-to-carbon ratio mole per mole mol/mol 1 C # number... error between a quantity and its reference e brake-specific emission or fuel consumption gram per... standard deviation S Sutherland constant kelvin K K SEE standard estimate of error T absolute temperature...
New calibrators for the Cepheid period-luminosity relation
NASA Technical Reports Server (NTRS)
Evans, Nancy R.
1992-01-01
IUE spectra of six Cepheids have been used to determine their absolute magnitudes from the spectral types of their binary companions. The stars observed are U Aql, V659 Cen, Y Lac, S Nor, V350 Sgr, and V636 Sco. The absolute magnitude for V659 Cen is more uncertain than for the others because its reddening is poorly determined and the spectral type is hotter than those of the others. In addition, a reddening law with extra absorption in the 2200 A region is necessary, although this has a negligible effect on the absolute magnitude. For the other Cepheids, and also Eta Aql and W Sgr, the standard deviation from the Feast and Walker period-luminosity-color (PLC) relation is 0.37 mag, confirming the previously estimated internal uncertainty. The absolute magnitudes for S Nor from the binary companion and from cluster membership are very similar. The preliminary PLC zero point is less than 2 sigma (+0.21 mag) different from that of Feast and Walker. The same narrowing of the instability strip at low luminosities found by Fernie is seen.
NASA Astrophysics Data System (ADS)
Kosar, Naveen; Mahmood, Tariq; Ayub, Khurshid
2017-12-01
Benchmark study has been carried out to find a cost effective and accurate method for bond dissociation energy (BDE) of carbon halogen (Csbnd X) bond. BDE of C-X bond plays a vital role in chemical reactions, particularly for kinetic barrier and thermochemistry etc. The compounds (1-16, Fig. 1) with Csbnd X bond used for current benchmark study are important reactants in organic, inorganic and bioorganic chemistry. Experimental data of Csbnd X bond dissociation energy is compared with theoretical results. The statistical analysis tools such as root mean square deviation (RMSD), standard deviation (SD), Pearson's correlation (R) and mean absolute error (MAE) are used for comparison. Overall, thirty-one density functionals from eight different classes of density functional theory (DFT) along with Pople and Dunning basis sets are evaluated. Among different classes of DFT, the dispersion corrected range separated hybrid GGA class along with 6-31G(d), 6-311G(d), aug-cc-pVDZ and aug-cc-pVTZ basis sets performed best for bond dissociation energy calculation of C-X bond. ωB97XD show the best performance with less deviations (RMSD, SD), mean absolute error (MAE) and a significant Pearson's correlation (R) when compared to experimental data. ωB97XD along with Pople basis set 6-311g(d) has RMSD, SD, R and MAE of 3.14 kcal mol-1, 3.05 kcal mol-1, 0.97 and -1.07 kcal mol-1, respectively.
40 CFR 60.2780 - What must I include in the deviation report?
Code of Federal Regulations, 2010 CFR
2010-07-01
... from the emission limitations or operating limit requirements. (b) The averaged and recorded data for those dates. (c) Duration and causes of each deviation from the emission limitations or operating limits... deviated from the emission limitations or operating limits specified in this subpart, include the six items...
NASA Astrophysics Data System (ADS)
Yang, L.; Wang, G.; Liu, H.
2017-12-01
Rising sea level has important direct impacts on coastal and island regions such as the Caribbean where the influence of sea-level rise is becoming more apparent. The Caribbean Sea is a semi-enclosed sea adjacent to the landmasses of South and Central America to the south and west, and the Greater Antilles and the Lesser Antilles separate it from the Atlantic Ocean to the north and east. The work focus on studying the relative and absolute sea-level changes by integrating tide gauge, GPS, and satellite altimetry datasets (1955-2016) within the Caribbean Sea. Further, the two main components of absolute sea-level change, ocean mass and steric sea-level changes, are respectively studied using GRACE, temperature, and salinity datasets (1955-2016). According to the analysis conducted, the sea-level change rates have considerable temporal and spatial variations, and estimates may be subject to the techniques used and observation periods. The average absolute sea-level rise rate is 1.8±0.3 mm/year for the period from 1955 to 2015 according to the integrated tide gauge and GPS observations; the average absolute sea-level rise rate is 3.5±0.6 mm/year for the period from 1993 to 2016 according to the satellite altimetry observations. This study shows that the absolute sea-level change budget in the Caribbean Sea is closed in the periods from 1955 to 2016, in which ocean mass change dominates the absolute sea-level rise. The absolute sea-level change budget is also closed in the periods from 2004 to 2016, in which steric sea-level rise dominates the absolute sea-level rise.
Scientific fraud in 20 falsified anesthesia papers : detection using financial auditing methods.
Hein, J; Zobrist, R; Konrad, C; Schuepfer, G
2012-06-01
Data from natural sources show counter-intuitive distribution patterns for the leading digits to the left of the decimal point and the digit 1 is observed more frequently than all other numbers. This pattern, which was first described by Newcomb and later confirmed by Benford, is used in financial and tax auditing to detect fraud. Deviations from the pattern indicate possible falsifications. Anesthesiology journals are affected not only by ghostwriting and plagiarism but also by counterfeiting. In the present study 20 publications in anesthesiology known to be falsified by an author were investigated for irregularities with respect to Benford's law using the χ(2)-test and the Z-test. In the 20 retracted publications an average first-digit frequency of 243.1 (standard deviation SD ± 118.2, range: 30-592) and an average second-digit frequency of 132.3 (SD ± 72.2, range: 15-383) were found. The observed distribution of the first and second digits to the left of the decimal point differed significantly (p< 0.01) from the expected distribution described by Benford. Only the observed absolute frequencies for digits 3, 4 and 5 did not differ significantly from the expected values. In an analysis of each paper 17 out of 20 studies differed significantly from the expected value for the first digit and 18 out of 20 studies varied significantly from the expected value of the second digit. Only one paper did not vary significantly from expected values for the digits to the left of the decimal. For comparison, a meta-analysis using complex mathematical procedures was chosen as a control. The analysis showed a first-digit distribution consistent with the Benford distribution. Thus, the method used in the present study seems to be sensitive for detecting fraud. Additional statements of specificity cannot yet be made as this requires further analysis of data that is definitely not falsified. Future studies exploring conformity might help prevent falsified studies from being published.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carver, R; Popple, R; Benhabib, S
Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10{sup 9}),more » resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT.« less
NASA Astrophysics Data System (ADS)
Larsson, R.; Milz, M.; Rayer, P.; Saunders, R.; Bell, W.; Booton, A.; Buehler, S. A.; Eriksson, P.; John, V.
2015-10-01
We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Same channel, there is 1.2 K in average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Same channel, there is 1.3 K in average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies causing up to ± 7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.
NASA Astrophysics Data System (ADS)
Larsson, Richard; Milz, Mathias; Rayer, Peter; Saunders, Roger; Bell, William; Booton, Anna; Buehler, Stefan A.; Eriksson, Patrick; John, Viju O.
2016-03-01
We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high-altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Concerning the same channel, there is 1.2 K on average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Regarding the same channel, there is 1.3 K on average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies, causing up to ±7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.
Mental health care and average happiness: strong effect in developed nations.
Touburg, Giorgio; Veenhoven, Ruut
2015-07-01
Mental disorder is a main cause of unhappiness in modern society and investment in mental health care is therefore likely to add to average happiness. This prediction was checked in a comparison of 143 nations around 2005. Absolute investment in mental health care was measured using the per capita number of psychiatrists and psychologists working in mental health care. Relative investment was measured using the share of mental health care in the total health budget. Average happiness in nations was measured with responses to survey questions about life-satisfaction. Average happiness appeared to be higher in countries that invest more in mental health care, both absolutely and relative to investment in somatic medicine. A data split by level of development shows that this difference exists only among developed nations. Among these nations the link between mental health care and happiness is quite strong, both in an absolute sense and compared to other known societal determinants of happiness. The correlation between happiness and share of mental health care in the total health budget is twice as strong as the correlation between happiness and size of the health budget. A causal effect is likely, but cannot be proved in this cross-sectional analysis.
Use of modern contraception by the poor is falling behind.
Gakidou, Emmanuela; Vayena, Effy
2007-02-01
The widespread increase in the use of contraception, due to multiple factors including improved access to modern contraception, is one of the most dramatic social transformations of the past fifty years. This study explores whether the global progress in the use of modern contraceptives has also benefited the poorest. Demographic and Health Surveys from 55 developing countries were analyzed using wealth indices that allow the identification of the absolute poor within each country. This article explores the macro level determinants of the differences in the use of modern contraceptives between the poor and the national averages of several countries. Despite increases in national averages, use of modern contraception by the absolute poor remains low. South and Southeast Asia have relatively high rates of modern contraception in the absolute poor, on average 17% higher than in Latin America. Over time the gaps in use persist and are increasing. Latin America exhibits significantly larger gaps in use between the poor and the averages, while gaps in sub-Saharan Africa are on average smaller by 15.8% and in Southeast Asia by 11.6%. The secular trend of increasing rates of modern contraceptive use has not resulted in a decrease of the gap in use for those living in absolute poverty. Countries with large economic inequalities also exhibit large inequalities in modern contraceptive use. In addition to macro level factors that influence contraceptive use, such as economic development and provision of reproductive health services, there are strong regional variations, with sub-Saharan Africa exhibiting the lowest national rates of use, South and Southeast Asia the highest use among the poor, and Latin America the largest inequalities in use.
Hura, Arjan S; Osher, Robert H
2017-07-01
To compare the alignment meridian generated by the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA) and the Alcon Verion Image Guided System (Alcon Laboratories, Inc., Fort Worth, TX). In this retrospective comparative evaluation of technology, intraoperative images were captured at different steps in the same surgery, allowing the comparison of the guidance lines generated by the Verion system to the parallel guidance lines generated by the Callisto Eye system. Measurements of each hemi-meridian were quantified using Adobe Photoshop 2015 CC software (Adobe Systems, San Jose, CA). The numbers of degrees separating these alignment meridians were calculated, entered into a database, and analyzed. The authors found that of 98 captured images of 16 eyes, the two technologies were identical in 0 eyes (θ 1 = θ 2 = 0), similar by 3° in 52 (53%) captured images (θ 1 ≠ θ 2 ≠ 0), and different by at least 3° in 46 (47%) captured images (θ 1 ≠ θ 2 ≠ 0). The target meridians were superimposed, the target lines were minimally separated, and the target lines were dissimilar. It was noted that some intraoperative variation occurred from measurement to measurement. Within the small group of 16 cases of routine toric lens implantation in this study, the absolute average number of degrees of misalignment between the Verion and Callisto Eye systems was 3.355 for θ 1 and 3.838 for θ 2 . On average, the intraoperative variation termed "drift" was noted to be 3.963° for θ 1 , and 4.557° for θ 2 . The authors found that small deviations were frequent when comparing two sophisticated technologies. Although deviations greater than 3° occurred in less than 47% of captured images from 16 eyes, smaller but significant variations of less than 3° occurred in 53% of captured images from 16 eyes. It was rare to identify a large deviation. However, the authors identified "drift" in the same eye when measurements were taken at different times. The results indicate that the two systems are not currently interchangeable. Superiority of one system over the other was not determined. [J Refract Surg. 2017;33(7):482-487.]. Copyright 2017, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Guleria, Raj Paul; Kuniyal, Jagdish Chandra; Rawat, Pan Singh; Thakur, Harinder Kumar; Sharma, Manum; Sharma, Nand Lal; Singh, Mahavir; Chand, Kesar; Sharma, Priyanka; Thakur, Ajay Kumar; Dhyani, Pitamber Prasad; Bhuyan, Pradip Kumar
2011-08-01
The present study deals with the aerosol optical property which carried out during April 2006 to March 2007 over Mohal (31.9°N, 77.12°E) in the northwestern Indian Himalaya. The study was conducted using ground based Multi-wavelength Radiometer (MWR) and Moderate Resolution Imaging Spectroradiometer (MODIS) sensor. The daily average aerosol optical depth (AOD) at 500 nm was found to be (mean ± standard deviation) 0.24 ± 0.10. The afternoon AOD values have been noticed to be higher than the forenoon AOD values. Spectral AOD values exhibited larger day-to-day variation in finer aerosols during the observation period. The daily average value of Ångström exponent 'α' and turbidity coefficient 'β' obtained was 1.10 ± 0.38 and 0.12 ± 0.08 respectively. Higher value of AOD ~ 0.39 ± 0.06 during summer associated with low α ~ 0.73 ± 0.28 has attributed to the increase in the relative dominance of coarse size particles. In winter α ~ 1.21 ± 0.32 indicating a considerable increase in fine size particles, attributed to the anthropogenic activities. The AOD spectra seem to be more wavelength dependent in winter as compared to summer. Comparison of MWR observation with MODIS observation indicates a good conformity between ground-based and satellite derived AOD. The root mean square deviation (RMSD), mean absolute bias deviation (MABD) and correlation coefficient have been found to be ~ 0.08, ~ 0.06 and ~ 0.77 respectively. These results suggest that the AOD retrieval through satellite can be able to characterize AOD distribution over Mohal. However, further efforts to eliminate systematic errors in the existing MODIS products are needed. During the observation period ~ 30%, ~ 47% and ~ 62% air parcels drawn at 4000, 5500 and 8000 m above ground level respectively reached at Mohal which passed through or originated from The Great Sahara. The maximum AOD at 500 nm occurred on 8 May 2006. This has caused a significant reduction in surface reaching solar irradiance by ~ 59 Wm -2. The back trajectory analysis suggested that the highest AOD during summer is due to high degree of human interference in the form of tourism and dust transport from the country lying in the northwestern part of India.
Size-dependent standard deviation for growth rates: Empirical results and theoretical modeling
NASA Astrophysics Data System (ADS)
Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H. Eugene; Grosse, I.
2008-05-01
We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation σ(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation σ(R) on the average value of the wages with a scaling exponent β≈0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation σ(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of σ(R) on the average payroll with a scaling exponent β≈-0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.
Size-dependent standard deviation for growth rates: empirical results and theoretical modeling.
Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H Eugene; Grosse, I
2008-05-01
We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation sigma(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation sigma(R) on the average value of the wages with a scaling exponent beta approximately 0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation sigma(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of sigma(R) on the average payroll with a scaling exponent beta approximately -0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.
Koenig, Bruce E; Lacey, Douglas S
2014-07-01
In this research project, nine small digital audio recorders were tested using five sets of 30-min recordings at all available recording modes, with consistent audio material, identical source and microphone locations, and identical acoustic environments. The averaged direct current (DC) offset values and standard deviations were measured for 30-sec and 1-, 2-, 3-, 6-, 10-, 15-, and 30-min segments. The research found an inverse association between segment lengths and the standard deviation values and that lengths beyond 30 min may not meaningfully reduce the standard deviation values. This research supports previous studies indicating that measured averaged DC offsets should only be used for exclusionary purposes in authenticity analyses and exhibit consistent values when the general acoustic environment and microphone/recorder configurations were held constant. Measured average DC offset values from exemplar recorders may not be directly comparable to those of submitted digital audio recordings without exactly duplicating the acoustic environment and microphone/recorder configurations. © 2014 American Academy of Forensic Sciences.
MetaMQAP: a meta-server for the quality assessment of protein models.
Pawlowski, Marcin; Gajda, Michal J; Matlak, Ryszard; Bujnicki, Janusz M
2008-09-29
Computational models of protein structure are usually inaccurate and exhibit significant deviations from the true structure. The utility of models depends on the degree of these deviations. A number of predictive methods have been developed to discriminate between the globally incorrect and approximately correct models. However, only a few methods predict correctness of different parts of computational models. Several Model Quality Assessment Programs (MQAPs) have been developed to detect local inaccuracies in unrefined crystallographic models, but it is not known if they are useful for computational models, which usually exhibit different and much more severe errors. The ability to identify local errors in models was tested for eight MQAPs: VERIFY3D, PROSA, BALA, ANOLEA, PROVE, TUNE, REFINER, PROQRES on 8251 models from the CASP-5 and CASP-6 experiments, by calculating the Spearman's rank correlation coefficients between per-residue scores of these methods and local deviations between C-alpha atoms in the models vs. experimental structures. As a reference, we calculated the value of correlation between the local deviations and trivial features that can be calculated for each residue directly from the models, i.e. solvent accessibility, depth in the structure, and the number of local and non-local neighbours. We found that absolute correlations of scores returned by the MQAPs and local deviations were poor for all methods. In addition, scores of PROQRES and several other MQAPs strongly correlate with 'trivial' features. Therefore, we developed MetaMQAP, a meta-predictor based on a multivariate regression model, which uses scores of the above-mentioned methods, but in which trivial parameters are controlled. MetaMQAP predicts the absolute deviation (in Angströms) of individual C-alpha atoms between the model and the unknown true structure as well as global deviations (expressed as root mean square deviation and GDT_TS scores). Local model accuracy predicted by MetaMQAP shows an impressive correlation coefficient of 0.7 with true deviations from native structures, a significant improvement over all constituent primary MQAP scores. The global MetaMQAP score is correlated with model GDT_TS on the level of 0.89. Finally, we compared our method with the MQAPs that scored best in the 7th edition of CASP, using CASP7 server models (not included in the MetaMQAP training set) as the test data. In our benchmark, MetaMQAP is outperformed only by PCONS6 and method QA_556 - methods that require comparison of multiple alternative models and score each of them depending on its similarity to other models. MetaMQAP is however the best among methods capable of evaluating just single models. We implemented the MetaMQAP as a web server available for free use by all academic users at the URL https://genesilico.pl/toolkit/
40 CFR 60.2220 - What must I include in the deviation report?
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 60.2215, for any pollutant or parameter that deviated from the emission limitations or operating... section. (a) The calendar dates and times your unit deviated from the emission limitations or operating limit requirements. (b) The averaged and recorded data for those dates. (c) Durations and causes of each...
Utrillas, María P; Marín, María J; Esteve, Anna R; Estellés, Victor; Tena, Fernando; Cañada, Javier; Martínez-Lozano, José A
2009-01-01
Values of measured and modeled diffuse UV erythemal irradiance (UVER) for all sky conditions are compared on planes inclined at 40 degrees and oriented north, south, east and west. The models used for simulating diffuse UVER are of the geometric-type, mainly the Isotropic, Klucher, Hay, Muneer, Reindl and Schauberger models. To analyze the precision of the models, some statistical estimators were used such as root mean square deviation, mean absolute deviation and mean bias deviation. It was seen that all the analyzed models reproduce adequately the diffuse UVER on the south-facing plane, with greater discrepancies for the other inclined planes. When the models are applied to cloud-free conditions, the errors obtained are higher because the anisotropy of the sky dome acquires more importance and the models do not provide the estimation of diffuse UVER accurately.
Dmitrieva, E S; Gel'man, V Ia; Zaĭtseva, K A; Orlov, A M
2009-01-01
Comparative study of acoustic correlates of emotional intonation was conducted on two types of speech material: sensible speech utterances and short meaningless words. The corpus of speech signals of different emotional intonations (happy, angry, frightened, sad and neutral) was created using the actor's method of simulation of emotions. Native Russian 20-70-year-old speakers (both professional actors and non-actors) participated in the study. In the corpus, the following characteristics were analyzed: mean values and standard deviations of the power, fundamental frequency, frequencies of the first and second formants, and utterance duration. Comparison of each emotional intonation with "neutral" utterances showed the greatest deviations of the fundamental frequency and frequencies of the first formant. The direction of these deviations was independent of the semantic content of speech utterance and its duration, age, gender, and being actor or non-actor, though the personal features of the speakers affected the absolute values of these frequencies.
Allan Deviation Plot as a Tool for Quartz-Enhanced Photoacoustic Sensors Noise Analysis.
Giglio, Marilena; Patimisco, Pietro; Sampaolo, Angelo; Scamarcio, Gaetano; Tittel, Frank K; Spagnolo, Vincenzo
2016-04-01
We report here on the use of the Allan deviation plot to analyze the long-term stability of a quartz-enhanced photoacoustic (QEPAS) gas sensor. The Allan plot provides information about the optimum averaging time for the QEPAS signal and allows the prediction of its ultimate detection limit. The Allan deviation can also be used to determine the main sources of noise coming from the individual components of the sensor. Quartz tuning fork thermal noise dominates for integration times up to 275 s, whereas at longer averaging times, the main contribution to the sensor noise originates from laser power instabilities.
NASA Astrophysics Data System (ADS)
Zint, M.; Stock, K.; Graser, R.; Ertl, T.; Brauer, E.; Heyninck, J.; Vanbiervliet, J.; Dhondt, S.; De Ceuninck, P.; Hibst, R.
2015-03-01
The presented work describes the development and verification of a novel optical, powder-free intra-oral scanner based on chromatic confocal technology combined with a multifocal approach. The proof of concept for a chromatic confocal area scanner for intra-oral scanning is given. Several prototype scanners passed a verification process showing an average accuracy (distance deviation on flat surfaces) of less than 31μm +/- 21μm and a reproducibility of less than 4μm +/- 3μm. Compared to a tactile measurement on a full jaw model fitted with 4mm ceramic spheres the measured average distance deviation between the spheres was 49μm +/- 12μm for scans of up to 8 teeth (3- unit bridge, single Quadrant) and 104μm +/- 82μm for larger scans and full jaws. The average deviation of the measured sphere diameter compared to the tactile measurement was 27μm +/- 14μm. Compared to μCT scans of plaster models equipped with human teeth the average standard deviation on up to 3 units was less than 55μm +/- 49μm whereas the reproducibility of the scans was better than 22μm +/- 10μm.
Observations on the method of determining the velocity of airships
NASA Technical Reports Server (NTRS)
Volterra, Vito
1921-01-01
To obtain the absolute velocity of an airship by knowing the speed at which two routes are covered, we have only to determine the geographical direction of the routes which we locate from a map, and the angles of routes as given by the compass, after correcting for the variation (the algebraical sum of the local magnetic declination and the deviation).
File Carving and Malware Identification Algorithms Applied to Firmware Reverse Engineering
2013-03-21
33 3.5 Performance Metrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 3.6 Experimental...consider a byte value rate-of-change frequency metric [32]. Their system calculates the absolute value of the distance between all consecutive bytes, then...the rate-of-change means and standard deviations. Karresand and Shahmehri use the same distance metric for both byte value frequency and rate-of-change
Time-Series Forecast Modeling on High-Bandwidth Network Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoo, Wucherl; Sim, Alex
With the increasing number of geographically distributed scientific collaborations and the growing sizes of scientific data, it has become challenging for users to achieve the best possible network performance on a shared network. In this paper, we have developed a model to forecast expected bandwidth utilization on high-bandwidth wide area networks. The forecast model can improve the efficiency of the resource utilization and scheduling of data movements on high-bandwidth networks to accommodate ever increasing data volume for large-scale scientific data applications. A univariate time-series forecast model is developed with the Seasonal decomposition of Time series by Loess (STL) and themore » AutoRegressive Integrated Moving Average (ARIMA) on Simple Network Management Protocol (SNMP) path utilization measurement data. Compared with the traditional approach such as Box-Jenkins methodology to train the ARIMA model, our forecast model reduces computation time up to 92.6 %. It also shows resilience against abrupt network usage changes. Finally, our forecast model conducts the large number of multi-step forecast, and the forecast errors are within the mean absolute deviation (MAD) of the monitored measurements.« less
NASA Astrophysics Data System (ADS)
Song, Yifei; Kujofsa, Tedi; Ayers, John E.
2018-07-01
In order to evaluate various buffer layers for metamorphic devices, threading dislocation densities have been calculated for uniform composition In x Ga1- x As device layers deposited on GaAs (001) substrates with an intermediate graded buffer layer using the L MD model, where L MD is the average length of misfit dislocations. On this basis, we compare the relative effectiveness of buffer layers with linear, exponential, and S-graded compositional profiles. In the case of a 2 μm thick buffer layer linear grading results in higher threading dislocation densities in the device layer compared to either exponential or S-grading. When exponential grading is used, lower threading dislocation densities are obtained with a smaller length constant. In the S-graded case, lower threading dislocation densities result when a smaller standard deviation parameter is used. As the buffer layer thickness is decreased from 2 μm to 0.1 μm all of the above effects are diminished, and the absolute threading dislocation densities increase.
NASA Astrophysics Data System (ADS)
Hemmat Esfe, Mohammad; Saedodin, Seyfolah; Rejvani, Mousa; Shahram, Jalal
2017-06-01
In the present study, rheological behavior of ZnO/10W40 nano-lubricant is investigated by an experimental approach. Firstly, ZnO nanoparticles of 10-30 nm were dispersed in 10W40 engine oil with solid volume fractions of 0.25-2%, then the viscosity of the composed nano-lubricant was measured in temperature ranges of 5-55 °C and in various shear rates. From analyzing the results, it was revealed that both of the base oil and nano-lubricants are non-Newtonian fluids which exhibit shear thinning behavior. Sensitivity of viscosity to the solid volume fraction enhancement was calculated by a new correlation which was proposed in terms of solid volume fraction and temperature. In order to attain an accurate model by which experimental data are predicted, an artificial neural network (ANN) with a hidden layer and 5 neurons was designed. This model was considerably accurate in predicting experimental data of dynamic viscosity as R-squared and average absolute relative deviation (AARD %) were respectively 0.9999 and 0.0502.
Buhr, H; Büermann, L; Gerlach, M; Krumrey, M; Rabus, H
2012-12-21
For the first time the absolute photon mass energy-absorption coefficient of air in the energy range of 10 to 60 keV has been measured with relative standard uncertainties below 1%, considerably smaller than those of up to 2% assumed for calculated data. For monochromatized synchrotron radiation from the electron storage ring BESSY II both the radiant power and the fraction of power deposited in dry air were measured using a cryogenic electrical substitution radiometer and a free air ionization chamber, respectively. The measured absorption coefficients were compared with state-of-the art calculations and showed an average deviation of 2% from calculations by Seltzer. However, they agree within 1% with data calculated earlier by Hubbell. In the course of this work, an improvement of the data analysis of a previous experimental determination of the mass energy-absorption coefficient of air in the range of 3 to 10 keV was found to be possible and corrected values of this preceding study are given.
NASA Astrophysics Data System (ADS)
Ghosh, Arpita; Das, Papita; Sinha, Keka
2015-06-01
In the present work, spent tea leaves were modified with Ca(OH)2 and used as a new, non-conventional and low-cost biosorbent for the removal of Cu(II) from aqueous solution. Response surface methodology (RSM) and artificial neural network (ANN) were used to develop predictive models for simulation and optimization of the biosorption process. The influence of process parameters (pH, biosorbent dose and reaction time) on the biosorption efficiency was investigated through a two-level three-factor (23) full factorial central composite design with the help of Design Expert. The same design was also used to obtain a training set for ANN. Finally, both modeling methodologies were statistically compared by the root mean square error and absolute average deviation based on the validation data set. Results suggest that RSM has better prediction performance as compared to ANN. The biosorption followed Langmuir adsorption isotherm and it followed pseudo-second-order kinetic. The optimum removal efficiency of the adsorbent was found as 96.12 %.
Effects of Nonlinear Inhomogeneity on the Cosmic Expansion with Numerical Relativity.
Bentivegna, Eloisa; Bruni, Marco
2016-06-24
We construct a three-dimensional, fully relativistic numerical model of a universe filled with an inhomogeneous pressureless fluid, starting from initial data that represent a perturbation of the Einstein-de Sitter model. We then measure the departure of the average expansion rate with respect to this homogeneous and isotropic reference model, comparing local quantities to the predictions of linear perturbation theory. We find that collapsing perturbations reach the turnaround point much earlier than expected from the reference spherical top-hat collapse model and that the local deviation of the expansion rate from the homogeneous one can be as high as 28% at an underdensity, for an initial density contrast of 10^{-2}. We then study, for the first time, the exact behavior of the backreaction term Q_{D}. We find that, for small values of the initial perturbations, this term exhibits a 1/a scaling, and that it is negative with a linearly growing absolute value for larger perturbation amplitudes, thereby contributing to an overall deceleration of the expansion. Its magnitude, on the other hand, remains very small even for relatively large perturbations.
Shanmugaprakash, M; Sivakumar, V
2013-11-01
In the present work, the evaluation capacities of two optimization methodologies such as RSM and ANN were employed and compared for predication of Cr(VI) uptake rate using defatted pongamia oil cake (DPOC) in both batch and column mode. The influence of operating parameters was investigated through a central composite design (CCD) of RSM using Design Expert 8.0.7.1 software. The same data was fed as input in ANN to obtain a trained the multilayer feed-forward networks back-propagation algorithm using MATLAB. The performance of the developed ANN models were compared with RSM mathematical models for Cr(VI) uptake rate in terms of the coefficient of determination (R(2)), root mean square error (RMSE) and absolute average deviation (AAD). The estimated values confirm that ANN predominates RSM representing the superiority of a trained ANN models over RSM models in order to capture the non-linear behavior of the given system. Copyright © 2013 Elsevier Ltd. All rights reserved.
Time-Series Forecast Modeling on High-Bandwidth Network Measurements
Yoo, Wucherl; Sim, Alex
2016-06-24
With the increasing number of geographically distributed scientific collaborations and the growing sizes of scientific data, it has become challenging for users to achieve the best possible network performance on a shared network. In this paper, we have developed a model to forecast expected bandwidth utilization on high-bandwidth wide area networks. The forecast model can improve the efficiency of the resource utilization and scheduling of data movements on high-bandwidth networks to accommodate ever increasing data volume for large-scale scientific data applications. A univariate time-series forecast model is developed with the Seasonal decomposition of Time series by Loess (STL) and themore » AutoRegressive Integrated Moving Average (ARIMA) on Simple Network Management Protocol (SNMP) path utilization measurement data. Compared with the traditional approach such as Box-Jenkins methodology to train the ARIMA model, our forecast model reduces computation time up to 92.6 %. It also shows resilience against abrupt network usage changes. Finally, our forecast model conducts the large number of multi-step forecast, and the forecast errors are within the mean absolute deviation (MAD) of the monitored measurements.« less
Maeda, Aya; Sakoguchi, Yoko; Miyawaki, Shouichi
2013-09-01
This report describes the treatment of a 20-year-old woman with a dental midline deviation and 7 congenitally missing premolars. She had retained a maxillary right deciduous canine and 4 deciduous second molars, and she had an impacted maxillary right third molar. The maxillary right deciduous second molar was extracted, and the space was nearly closed by mesial movement of the maxillary right molars using an edgewise appliance and a miniscrew for absolute anchorage. The miniscrew was removed, and the extraction space of the maxillary right deciduous canine was closed, correcting the dental midline deviation. After the mesial movement of the maxillary right molars, the impacted right third molar was aligned. To prevent root resorption, the retained left deciduous second molars were not aligned by the edgewise appliance. The occlusal contact area and the maximum occlusal force increased over the 2 years of retention. The miniscrew was useful for absolute anchorage for unilateral mesial movement of the maxillary molars and for the creation of eruption space and alignment of the impacted third molar in a patient with oligodontia. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
March, Rod S.
2003-01-01
The 1996 measured winter snow, maximum winter snow, net, and annual balances in the Gulkana Glacier Basin were evaluated on the basis of meteorological, hydrological, and glaciological data. Averaged over the glacier, the measured winter snow balance was 0.87 meter on April 18, 1996, 1.1 standard deviation below the long-term average; the maximum winter snow balance, 1.06 meters, was reached on May 28, 1996; and the net balance (from August 30, 1995, to August 24, 1996) was -0.53 meter, 0.53 standard deviation below the long-term average. The annual balance (October 1, 1995, to September 30, 1996) was -0.37 meter. Area-averaged balances were reported using both the 1967 and 1993 area altitude distributions (the numbers previously given in this abstract use the 1993 area altitude distribution). Net balance was about 25 percent less negative using the 1993 area altitude distribution than the 1967 distribution. Annual average air temperature was 0.9 degree Celsius warmer than that recorded with the analog sensor used since 1966. Total precipitation catch for the year was 0.78 meter, 0.8 standard deviations below normal. The annual average wind speed was 3.5 meters per second in the first year of measuring wind speed. Annual runoff averaged 1.50 meters over the basin, 1.0 standard deviation below the long-term average. Glacier-surface altitude and ice-motion changes measured at three index sites document seasonal ice-speed and glacier-thickness changes. Both showed a continuation of a slowing and thinning trend present in the 1990s. The glacier terminus and lower ablation area were defined for 1996 with a handheld Global Positioning System survey of 126 locations spread out over about 4 kilometers on the lower glacier margin. From 1949 to 1996, the terminus retreated about 1,650 meters for an average retreat rate of 35 meters per year.
Benchmarking the Bethe–Salpeter Formalism on a Standard Organic Molecular Set
2015-01-01
We perform benchmark calculations of the Bethe–Salpeter vertical excitation energies for the set of 28 molecules constituting the well-known Thiel’s set, complemented by a series of small molecules representative of the dye chemistry field. We show that Bethe–Salpeter calculations based on a molecular orbital energy spectrum obtained with non-self-consistent G0W0 calculations starting from semilocal DFT functionals dramatically underestimate the transition energies. Starting from the popular PBE0 hybrid functional significantly improves the results even though this leads to an average −0.59 eV redshift compared to reference calculations for Thiel’s set. It is shown, however, that a simple self-consistent scheme at the GW level, with an update of the quasiparticle energies, not only leads to a much better agreement with reference values, but also significantly reduces the impact of the starting DFT functional. On average, the Bethe–Salpeter scheme based on self-consistent GW calculations comes close to the best time-dependent DFT calculations with the PBE0 functional with a 0.98 correlation coefficient and a 0.18 (0.25) eV mean absolute deviation compared to TD-PBE0 (theoretical best estimates) with a tendency to be red-shifted. We also observe that TD-DFT and the standard adiabatic Bethe–Salpeter implementation may differ significantly for states implying a large multiple excitation character. PMID:26207104
NASA Astrophysics Data System (ADS)
Joshi, K. D.; Marchant, T. E.; Moore, C. J.
2017-03-01
A shading correction algorithm for the improvement of cone-beam CT (CBCT) images (Phys. Med. Biol. 53 5719{33) has been further developed, optimised and validated extensively using 135 clinical CBCT images of patients undergoing radiotherapy treatment of the pelvis, lungs and head and neck. An automated technique has been developed to efficiently analyse the large number of clinical images. Small regions of similar tissue (for example fat tissue) are automatically identified using CT images. The same regions on the corresponding CBCT image are analysed to ensure that they do not contain pixels representing multiple types of tissue. The mean value of all selected pixels and the non-uniformity, defined as the median absolute deviation of the mean values in each small region, are calculated. Comparisons between CT and raw and corrected CBCT images are then made. Analysis of fat regions in pelvis images shows an average difference in mean pixel value between CT and CBCT of 136:0 HU in raw CBCT images, which is reduced to 2:0 HU after the application of the shading correction algorithm. The average difference in non-uniformity of fat pixels is reduced from 33:7 in raw CBCT to 2:8 in shading-corrected CBCT images. Similar results are obtained in the analysis of lung and head and neck images.
Chen, Raymond; Ilasi, Nicholas; Sekulic, Sonja S
2011-12-05
Molecular weight distribution is an important quality attribute for hypromellose acetate succinate (HPMCAS), a pharmaceutical excipient used in spray-dried dispersions. Our previous study showed that neither relative nor universal calibration method of size exclusion chromatography (SEC) works for HPMCAS polymers. We here report our effort to develop a SEC method using a mass sensitive multi angle laser light scattering detector (MALLS) to determine molecular weight distributions of HPMCAS polymers. A solvent screen study reveals that a mixed solvent (60:40%, v/v 50mM NaH(2)PO(4) with 0.1M NaNO(3) buffer: acetonitrile, pH* 8.0) is the best for HPMCAS-LF and MF sub-classes. Use of a mixed solvent creates a challenging condition for the method that uses refractive index detector. Therefore, we thoroughly evaluated the method performance and robustness. The mean weight average molecular weight of a polyethylene oxide standard has a 95% confidence interval of (28,443-28,793) g/mol vs. 28,700g/mol from the Certificate of Analysis. The relative standard deviations of average molecular weights for all polymers are 3-6%. These results and the Design of Experiments study demonstrate that the method is accurate and robust. Copyright © 2011 Elsevier B.V. All rights reserved.
Measuring radio-signal power accurately
NASA Technical Reports Server (NTRS)
Goldstein, R. M.; Newton, J. W.; Winkelstein, R. A.
1979-01-01
Absolute value of signal power in weak radio signals is determined by computer-aided measurements. Equipment operates by averaging received signal over several-minute period and comparing average value with noise level of receiver previously calibrated.
Laser frequency stabilization using a commercial wavelength meter
NASA Astrophysics Data System (ADS)
Couturier, Luc; Nosske, Ingo; Hu, Fachao; Tan, Canzhu; Qiao, Chang; Jiang, Y. H.; Chen, Peng; Weidemüller, Matthias
2018-04-01
We present the characterization of a laser frequency stabilization scheme using a state-of-the-art wavelength meter based on solid Fizeau interferometers. For a frequency-doubled Ti-sapphire laser operated at 461 nm, an absolute Allan deviation below 10-9 with a standard deviation of 1 MHz over 10 h is achieved. Using this laser for cooling and trapping of strontium atoms, the wavemeter scheme provides excellent stability in single-channel operation. Multi-channel operation with a multimode fiber switch results in fluctuations of the atomic fluorescence correlated to residual frequency excursions of the laser. The wavemeter-based frequency stabilization scheme can be applied to a wide range of atoms and molecules for laser spectroscopy, cooling, and trapping.
Estimating error statistics for Chambon-la-Forêt observatory definitive data
NASA Astrophysics Data System (ADS)
Lesur, Vincent; Heumez, Benoît; Telali, Abdelkader; Lalanne, Xavier; Soloviev, Anatoly
2017-08-01
We propose a new algorithm for calibrating definitive observatory data with the goal of providing users with estimates of the data error standard deviations (SDs). The algorithm has been implemented and tested using Chambon-la-Forêt observatory (CLF) data. The calibration process uses all available data. It is set as a large, weakly non-linear, inverse problem that ultimately provides estimates of baseline values in three orthogonal directions, together with their expected standard deviations. For this inverse problem, absolute data error statistics are estimated from two series of absolute measurements made within a day. Similarly, variometer data error statistics are derived by comparing variometer data time series between different pairs of instruments over few years. The comparisons of these time series led us to use an autoregressive process of order 1 (AR1 process) as a prior for the baselines. Therefore the obtained baselines do not vary smoothly in time. They have relatively small SDs, well below 300 pT when absolute data are recorded twice a week - i.e. within the daily to weekly measures recommended by INTERMAGNET. The algorithm was tested against the process traditionally used to derive baselines at CLF observatory, suggesting that statistics are less favourable when this latter process is used. Finally, two sets of definitive data were calibrated using the new algorithm. Their comparison shows that the definitive data SDs are less than 400 pT and may be slightly overestimated by our process: an indication that more work is required to have proper estimates of absolute data error statistics. For magnetic field modelling, the results show that even on isolated sites like CLF observatory, there are very localised signals over a large span of temporal frequencies that can be as large as 1 nT. The SDs reported here encompass signals of a few hundred metres and less than a day wavelengths.
NASA Astrophysics Data System (ADS)
Bertincourt, B.; Lagache, G.; Martin, P. G.; Schulz, B.; Conversi, L.; Dassas, K.; Maurin, L.; Abergel, A.; Beelen, A.; Bernard, J.-P.; Crill, B. P.; Dole, H.; Eales, S.; Gudmundsson, J. E.; Lellouch, E.; Moreno, R.; Perdereau, O.
2016-04-01
We compare the absolute gain photometric calibration of the Planck/HFI and Herschel/SPIRE instruments on diffuse emission. The absolute calibration of HFI and SPIRE each relies on planet flux measurements and comparison with theoretical far-infrared emission models of planetary atmospheres. We measure the photometric cross calibration between the instruments at two overlapping bands, 545 GHz/500 μm and 857 GHz/350 μm. The SPIRE maps used have been processed in the Herschel Interactive Processing Environment (Version 12) and the HFI data are from the 2015 Public Data Release 2. For our study we used 15 large fields observed with SPIRE, which cover a total of about 120 deg2. We have selected these fields carefully to provide high signal-to-noise ratio, avoid residual systematics in the SPIRE maps, and span a wide range of surface brightness. The HFI maps are bandpass-corrected to match the emission observed by the SPIRE bandpasses. The SPIRE maps are convolved to match the HFI beam and put on a common pixel grid. We measure the cross-calibration relative gain between the instruments using two methods in each field, pixel-to-pixel correlation and angular power spectrum measurements. The SPIRE/HFI relative gains are 1.047 (±0.0069) and 1.003 (±0.0080) at 545 and 857 GHz, respectively, indicating very good agreement between the instruments. These relative gains deviate from unity by much less than the uncertainty of the absolute extended emission calibration, which is about 6.4% and 9.5% for HFI and SPIRE, respectively, but the deviations are comparable to the values 1.4% and 5.5% for HFI and SPIRE if the uncertainty from models of the common calibrator can be discounted. Of the 5.5% uncertainty for SPIRE, 4% arises from the uncertainty of the effective beam solid angle, which impacts the adopted SPIRE point source to extended source unit conversion factor, highlighting that as a focus for refinement.
Automated time series forecasting for biosurveillance.
Burkom, Howard S; Murphy, Sean Patrick; Shmueli, Galit
2007-09-30
For robust detection performance, traditional control chart monitoring for biosurveillance is based on input data free of trends, day-of-week effects, and other systematic behaviour. Time series forecasting methods may be used to remove this behaviour by subtracting forecasts from observations to form residuals for algorithmic input. We describe three forecast methods and compare their predictive accuracy on each of 16 authentic syndromic data streams. The methods are (1) a non-adaptive regression model using a long historical baseline, (2) an adaptive regression model with a shorter, sliding baseline, and (3) the Holt-Winters method for generalized exponential smoothing. Criteria for comparing the forecasts were the root-mean-square error, the median absolute per cent error (MedAPE), and the median absolute deviation. The median-based criteria showed best overall performance for the Holt-Winters method. The MedAPE measures over the 16 test series averaged 16.5, 11.6, and 9.7 for the non-adaptive regression, adaptive regression, and Holt-Winters methods, respectively. The non-adaptive regression forecasts were degraded by changes in the data behaviour in the fixed baseline period used to compute model coefficients. The mean-based criterion was less conclusive because of the effects of poor forecasts on a small number of calendar holidays. The Holt-Winters method was also most effective at removing serial autocorrelation, with most 1-day-lag autocorrelation coefficients below 0.15. The forecast methods were compared without tuning them to the behaviour of individual series. We achieved improved predictions with such tuning of the Holt-Winters method, but practical use of such improvements for routine surveillance will require reliable data classification methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hazelaar, Colien, E-mail: c.hazelaar@vumc.nl; Dahele, Max; Mostafavi, Hassan
Purpose: Spine stereotactic body radiation therapy (SBRT) requires highly accurate positioning. We report our experience with markerless template matching and triangulation of kilovoltage images routinely acquired during spine SBRT, to determine spine position. Methods and Materials: Kilovoltage images, continuously acquired at 7, 11 or 15 frames/s during volumetric modulated spine SBRT of 18 patients, consisting of 93 fluoroscopy datasets (1 dataset/arc), were analyzed off-line. Four patients were immobilized in a head/neck mask, 14 had no immobilization. Two-dimensional (2D) templates were created for each gantry angle from planning computed tomography data and registered to prefiltered kilovoltage images to determine 2D shiftsmore » between actual and planned spine position. Registrations were considered valid if the normalized cross correlation score was ≥0.15. Multiple registrations were triangulated to determine 3D position. For each spine position dataset, average positional offset and standard deviation were calculated. To verify the accuracy and precision of the technique, mean positional offset and standard deviation for twenty stationary phantom datasets with different baseline shifts were measured. Results: For the phantom, average standard deviations were 0.18 mm for left-right (LR), 0.17 mm for superior-inferior (SI), and 0.23 mm for the anterior-posterior (AP) direction. Maximum difference in average detected and applied shift was 0.09 mm. For the 93 clinical datasets, the percentage of valid matched frames was, on average, 90.7% (range: 49.9-96.1%) per dataset. Average standard deviations for all datasets were 0.28, 0.19, and 0.28 mm for LR, SI, and AP, respectively. Spine position offsets were, on average, −0.05 (range: −1.58 to 2.18), −0.04 (range: −3.56 to 0.82), and −0.03 mm (range: −1.16 to 1.51), respectively. Average positional deviation was <1 mm in all directions in 92% of the arcs. Conclusions: Template matching and triangulation using kilovoltage images acquired during irradiation allows spine position detection with submillimeter accuracy at subsecond intervals. Although the majority of patients were not immobilized, most vertebrae were stable at the sub-mm level during spine SBRT delivery.« less
LD-SPatt: large deviations statistics for patterns on Markov chains.
Nuel, G
2004-01-01
Statistics on Markov chains are widely used for the study of patterns in biological sequences. Statistics on these models can be done through several approaches. Central limit theorem (CLT) producing Gaussian approximations are one of the most popular ones. Unfortunately, in order to find a pattern of interest, these methods have to deal with tail distribution events where CLT is especially bad. In this paper, we propose a new approach based on the large deviations theory to assess pattern statistics. We first recall theoretical results for empiric mean (level 1) as well as empiric distribution (level 2) large deviations on Markov chains. Then, we present the applications of these results focusing on numerical issues. LD-SPatt is the name of GPL software implementing these algorithms. We compare this approach to several existing ones in terms of complexity and reliability and show that the large deviations are more reliable than the Gaussian approximations in absolute values as well as in terms of ranking and are at least as reliable as compound Poisson approximations. We then finally discuss some further possible improvements and applications of this new method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jafarov, E. E.; Parsekian, A. D.; Schaefer, K.
Ground penetrating radar (GPR) has emerged as an effective tool for estimating active layer thickness (ALT) and volumetric water content (VWC) within the active layer. In August 2013, we conducted a series of GPR and probing surveys using a 500 MHz antenna and metallic probe around Barrow, Alaska. Here, we collected about 15 km of GPR data and 1.5 km of probing data. We describe the GPR data processing workflow from raw GPR data to the estimated ALT and VWC. We then include the corresponding uncertainties for each measured and estimated parameter. The estimated average GPR-derived ALT was 41 cm,more » with a standard deviation of 9 cm. The average probed ALT was 40 cm, with a standard deviation of 12 cm. The average GPR-derived VWC was 0.65, with a standard deviation of 0.14.« less
Jafarov, E. E.; Parsekian, A. D.; Schaefer, K.; ...
2018-01-09
Ground penetrating radar (GPR) has emerged as an effective tool for estimating active layer thickness (ALT) and volumetric water content (VWC) within the active layer. In August 2013, we conducted a series of GPR and probing surveys using a 500 MHz antenna and metallic probe around Barrow, Alaska. Here, we collected about 15 km of GPR data and 1.5 km of probing data. We describe the GPR data processing workflow from raw GPR data to the estimated ALT and VWC. We then include the corresponding uncertainties for each measured and estimated parameter. The estimated average GPR-derived ALT was 41 cm,more » with a standard deviation of 9 cm. The average probed ALT was 40 cm, with a standard deviation of 12 cm. The average GPR-derived VWC was 0.65, with a standard deviation of 0.14.« less
NASA Astrophysics Data System (ADS)
Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.
2016-12-01
Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, R; Bai, W
Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) weremore » delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.« less
Current Reversals of an Underdamped Brownian Particle in an Asymmetric Deformable Potential
NASA Astrophysics Data System (ADS)
Cai, Chun-Chun; Liu, Jian-Li; Chen, Hao; Li, Feng-Guo
2018-03-01
Transport of an underdamped Brownian particle in a one-dimensional asymmetric deformable potential is investigated in the presence of both an ac force and a static force, respectively. From numerical simulations, we obtain the current average velocity. The current reversals and the absolute negative mobility are presented. The increasing of the deformation of the potential can cause the absolute negative mobility to be suppressed and even disappear. When the static force is small, the increase of the potential deformation suppresses the absolute negative mobility. When the force is large, the absolute negative mobility disappears. In particular, when the potential deformation is equal to 0.015, the two current reversals present with the increasing of the force. Remarkably, when the potential deformation is small, there are three current reversals with the increasing of the friction coefficient and the average velocity presents a oscillation behavior. Supported in part by the National Natural Science Foundation of China under Grant Nos. 11575064 and 11175067, and the Natural Science Foundation of Guangdong Province under Grant No. 2016A030313433
First metatarsal length change after basilar closing wedge osteotomy for hallux valgus.
Day, Thomas; Charlton, Timothy P; Thordarson, David B
2011-05-01
Hallux valgus deformities with large intermetatarsal angles require a more proximal metatarsal procedure to adequately correct the deformity. Due to the relative ease of a closing wedge osteotomy, this technique was adopted but with concern over first metatarsal shortening. In this study, we primarily evaluated angular correction and first metatarsal shortening. We evaluated 70 feet in 57 patients (average age, 54 years) with 52 female and five male. The average followup was 14 (range, 6 to 45) months. The charts were reviewed for the presence of metatarsalgia. Digital radiographic measurements were made for pre- and postoperative hallux valgus and intermetatarsal angles, dorsiflexion angle of the first metatarsal, and absolute and relative shortening of the first metatarsal. The average hallux valgus angle improved from 31 to 11 degrees (p < 0.0001) and intermetatarsal angle from 13.2 to 4.4 angles (p < 0.0001). The absolute shortening of the first metatarsal was 2.2 mm and relative shortening was 0.6 mm. There was 1.3 degrees of dorsiflexion on average. Excellent correction of the deformity with minimal dorsiflexion or new complaints of metatarsalgia was found with this technique. The new method of assessing the relative shortening found to be less than the absolute shortening, which we feel more accurately reflects the functional length of the first metatarsal.
Regional comparison of absolute gravimeters SIM.M.G-K1 key comparison
NASA Astrophysics Data System (ADS)
Newell, D. B.; van Westrum, D.; Francis, O.; Kanney, J.; Liard, J.; Ramirez, A. E.; Lucero, B.; Ellis, B.; Greco, F.; Pistorio, A.; Reudink, R.; Iacovone, D.; Baccaro, F.; Silliker, J.; Wheeler, R. D.; Falk, R.; Ruelke, A.
2017-01-01
Twelve absolute gravimeters were compared during the regional Key Comparison SIM.M.G-K1 of absolute gravimeters. The four gravimeters were from different NMIs and DIs. The comparison was linked to the CCM.G-K2 through EURAMET.M.G-K2 via the DI gravimeter FG5X-216. Overall, the results and uncertainties indicate an excellent agreement among the gravimeters, with a standard deviation of the gravimeters' DoEs better than 1.3 μGal. In the case of the official solution, all the gravimeters are in equivalence well within the declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Wu, Hanzhong; Zhang, Fumin; Liu, Tingyang; Li, Jianshuang; Qu, Xinghua
2016-10-17
Two-color interferometry is powerful for the correction of the air refractive index especially in the turbulent air over long distance, since the empirical equations could introduce considerable measurement uncertainty if the environmental parameters cannot be measured with sufficient precision. In this paper, we demonstrate a method for absolute distance measurement with high-accuracy correction of air refractive index using two-color dispersive interferometry. The distances corresponding to the two wavelengths can be measured via the spectrograms captured by a CCD camera pair in real time. In the long-term experiment of the correction of air refractive index, the experimental results show a standard deviation of 3.3 × 10-8 for 12-h continuous measurement without the precise knowledge of the environmental conditions, while the variation of the air refractive index is about 2 × 10-6. In the case of absolute distance measurement, the comparison with the fringe counting interferometer shows an agreement within 2.5 μm in 12 m range.
3D shape measurements with a single interferometric sensor for in-situ lathe monitoring
NASA Astrophysics Data System (ADS)
Kuschmierz, R.; Huang, Y.; Czarske, J.; Metschke, S.; Löffler, F.; Fischer, A.
2015-05-01
Temperature drifts, tool deterioration, unknown vibrations as well as spindle play are major effects which decrease the achievable precision of computerized numerically controlled (CNC) lathes and lead to shape deviations between the processed work pieces. Since currently no measurement system exist for fast, precise and in-situ 3d shape monitoring with keyhole access, much effort has to be made to simulate and compensate these effects. Therefore we introduce an optical interferometric sensor for absolute 3d shape measurements, which was integrated into a working lathe. According to the spindle rotational speed, a measurement rate of 2,500 Hz was achieved. In-situ absolute shape, surface profile and vibration measurements are presented. While thermal drifts of the sensor led to errors of several mµm for the absolute shape, reference measurements with a coordinate machine show, that the surface profile could be measured with an uncertainty below one micron. Additionally, the spindle play of 0.8 µm was measured with the sensor.
Rectangularization of the survival curve in The Netherlands, 1950-1992.
Nusselder, W J; Mackenbach, J P
1996-12-01
In this article we determine whether rectangularization of the survival curve occurred in the Netherlands in the period 1950-1992. Rectangularization is defined as a trend toward a more rectangular shape of the survival curve due to increased survival and concentration of deaths around the mean age at death. We distinguish between absolute and relative rectangularization, depending on whether an increase in life expectancy is accompanied by concentration of deaths into a smaller age interval or into a smaller proportion of total life expectancy. We used measures of variability based on Keyfitz' H and the standard deviation, both life table-based. Our results show that absolute and relative rectangularization of the entire survival curve occurred in both sexes and over the complete period (except for the years 1955-1959 and 1965-1969 in men). At older ages, results differ between sexes, periods, and an absolute versus a relative definition of rectangularization. Above age 60 1/2, relative rectangularization occurred in women over the complete period and in men since 1975-1979 only, whereas absolute rectangularization occurred in both sexes since the period of 1980-1984. The implications of the recent rectangularization at older ages for achieving compression of morbidity are discussed.
Determining the Equation of State (EoS) Parameters for Ballistic Gelatin
2015-09-01
standard deviation. The specific heat measured at room temperature reported in (Winter 1975) is approximately 1.13 cal/g/°C (= 4.73 J /g/K). Fig. 4...Piatt 2010) Table 3 Specific heat capacity, average heat capacity, and standard deviation Temperature (°C) Cp [ J /(g·K)] Cp Cp Cp Average Cp...density amorphous ice and their implications on pressure induced amorphization. J Chem Physics. 2005;122:124710. Appleby-Thomas GJ, Hazell PJ
2015-01-01
The 0–0 energies of 80 medium and large molecules have been computed with a large panel of theoretical formalisms. We have used an approach computationally tractable for large molecules, that is, the structural and vibrational parameters are obtained with TD-DFT, the solvent effects are accounted for with the PCM model, whereas the total and transition energies have been determined with TD-DFT and with five wave function approaches accounting for contributions from double excitations, namely, CIS(D), ADC(2), CC2, SCS-CC2, and SOS-CC2, as well as Green’s function based BSE/GW approach. Atomic basis sets including diffuse functions have been systematically applied, and several variations of the PCM have been evaluated. Using solvent corrections obtained with corrected linear-response approach, we found that three schemes, namely, ADC(2), CC2, and BSE/GW allow one to reach a mean absolute deviation smaller than 0.15 eV compared to the measurements, the two former yielding slightly better correlation with experiments than the latter. CIS(D), SCS-CC2, and SOS-CC2 provide significantly larger deviations, though the latter approach delivers highly consistent transition energies. In addition, we show that (i) ADC(2) and CC2 values are extremely close to each other but for systems absorbing at low energies; (ii) the linear-response PCM scheme tends to overestimate solvation effects; and that (iii) the average impact of nonequilibrium correction on 0–0 energies is negligible. PMID:26574326
NASA Astrophysics Data System (ADS)
Takahata, Yuji; Chong, Delano P.
For substituted benzenes such as (p-F-C6H4-Z), Linderberg et al. 1 demonstrated the validity of an equation similar to: ΔCEBE ≈ κσ, where ΔCEBE is the difference in core-electron binding energies (CEBEs) of the fluorinated carbon in p-F-C6H4-Z and that in FC6H5, the parameter κ is a function of the type of reaction, and σ is the Hammett substituent (σ) constant. In this work, CEBEs of ring carbon atoms for a series of para disubstituted molecules p-F-C6H4-Z were first calculated using Density Functional Theory (DFT) with the scheme ΔEKS (PW86-PW91)/TZP+Crel//HF/6-31G*. An average absolute deviation of 0.13 eV from experiment was obtained for the CEBEs. Then we performed a linear regression analysis in the form of Y = A+B*X for a plot of Hammett σp constants against calculated shifts ΔCEBEs (in eV) for the fluorinated carbon. The results were: A = -0.08 and B = 1.01, with correlation coefficient R = 0.973, standard deviation = 0.12, and P < 0.0001. The intercept A of the fitted line, close to zero, shows that the Hammett σp constant is proportional to the calculated ΔCEBEs. On the other hand, the slope B of the straight line gives an estimate of the parameter κ. Similar statistical correlations were obtained for the carbon atoms ortho and meta to the substituent Z.
Global model of the F2 layer peak height for low solar activity based on GPS radio-occultation data
NASA Astrophysics Data System (ADS)
Shubin, V. N.; Karpachev, A. T.; Tsybulya, K. G.
2013-11-01
We propose a global median model SMF2 (Satellite Model of the F2 layer) of the ionospheric F2-layer height maximum (hmF2), based on GPS radio-occultation data for low solar activity periods (F10.7A<80). The model utilizes data provided by GPS receivers onboard satellites CHAMP (~100,000 hmF2 values), GRACE (~70,000) and COSMIC (~2,000,000). The data were preprocessed to remove cases where the absolute maximum of the electron density lies outside the F2 region. Ground-based ionospheric sounding data were used for comparison and validation. Spatial dependence of hmF2 is modeled by a Legendre-function expansion. Temporal dependence, as a function of Universal Time (UT), is described by a Fourier expansion. Inputs of the model are: geographical coordinates, month and F10.7A solar activity index. The model is designed for quiet geomagnetic conditions (Kр=1-2), typical for low solar activity. SMF2 agrees well with the International Reference Ionosphere model (IRI) in those regions, where the ground-based ionosonde network is dense. Maximal difference between the models is found in the equatorial belt, over the oceans and the polar caps. Standard deviations of the radio-occultation and Digisonde data from the predicted SMF2 median are 10-16 km for all seasons, against 13-29 km for IRI-2012. Average relative deviations are 3-4 times less than for IRI, 3-4% against 9-12%. Therefore, the proposed hmF2 model is more accurate than IRI-2012.
Weinstein, Ronald S; Krupinski, Elizabeth A; Weinstein, John B; Graham, Anna R; Barker, Gail P; Erps, Kristine A; Holtrust, Angelette L; Holcomb, Michael J
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school ( F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender ( F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level ( F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student's expectations. One class voted K-12 general pathology their "elective course-of-the-year."
Flexner 3.0—Democratization of Medical Knowledge for the 21st Century
Krupinski, Elizabeth A.; Weinstein, John B.; Graham, Anna R.; Barker, Gail P.; Erps, Kristine A.; Holtrust, Angelette L.; Holcomb, Michael J.
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school (F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender (F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level (F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student’s expectations. One class voted K-12 general pathology their “elective course-of-the-year.” PMID:28725762
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierce, Karisa M.; Wright, Bob W.; Synovec, Robert E.
2007-02-02
First, simulated chromatographic separations with declining retention time precision were used to study the performance of the piecewise retention time alignment algorithm and to demonstrate an unsupervised parameter optimization method. The average correlation coefficient between the first chromatogram and every other chromatogram in the data set was used to optimize the alignment parameters. This correlation method does not require a training set, so it is unsupervised and automated. This frees the user from needing to provide class information and makes the alignment algorithm more generally applicable to classifying completely unknown data sets. For a data set of simulated chromatograms wheremore » the average chromatographic peak was shifted past two neighboring peaks between runs, the average correlation coefficient of the raw data was 0.46 ± 0.25. After automated, optimized piecewise alignment, the average correlation coefficient was 0.93 ± 0.02. Additionally, a relative shift metric and principal component analysis (PCA) were used to independently quantify and categorize the alignment performance, respectively. The relative shift metric was defined as four times the standard deviation of a given peak’s retention time in all of the chromatograms, divided by the peak-width-at-base. The raw simulated data sets that were studied contained peaks with average relative shifts ranging between 0.3 and 3.0. Second, a “real” data set of gasoline separations was gathered using three different GC methods to induce severe retention time shifting. In these gasoline separations, retention time precision improved ~8 fold following alignment. Finally, piecewise alignment and the unsupervised correlation optimization method were applied to severely shifted GC separations of reformate distillation fractions. The effect of piecewise alignment on peak heights and peak areas is also reported. Piecewise alignment either did not change the peak height, or caused it to slightly decrease. The average relative difference in peak height after piecewise alignment was –0.20%. Piecewise alignment caused the peak areas to either stay the same, slightly increase, or slightly decrease. The average absolute relative difference in area after piecewise alignment was 0.15%.« less
SU-E-T-636: ProteusONE Machine QA Procedure and Stabiity Study: Half Year Clinical Operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freund, D; Ding, X; Wu, H
2015-06-15
Purpose: The objective of this study is to evaluate the stability of ProteusOne, the 1st commercial PBS proton system, throughout the daily QA and monthly over 6 month clinical operation. Method: Daily QA test includes IGRT position/repositioning, output in the middle of SOBP, beam flatness, symmetry, inplane and crossplane dimensions as well as energy range check. Daily range shifter QA consist of output, symmetry and field size checks to make sure its integrity. In 30 mins Daily QA test, all the measurements are performed using the MatriXXPT (IBA dosimetry). The data from these measurement was collected and compare over themore » first 6 month of clinical operation. In addition to the items check in daily QA, the summary also includes the monthly QA gantry star shots, absolute position check using a novel device, XRV-100. Results: Average machine output at the center of the spread out bragg peak was 197.5±.8 cGy and was within 1%of the baseline at 198.4 cGy. Beam flatness was within 1% cross plane with an average of 0.67±0.12% and 2% in-plane with an average of 1.08±0.17% compared to baseline measurements of 0.6 and 1.03, respectively. In all cases the radiation isocenter shift was less than or equal to 1mm. Output for the range shifter was within 2% for each individual measurement and averaged 34.4±.2cGy compare to a baseline reading of 34.5cGy. The average range shifter in and cross plane field size measurements were 19.8±0.5cm and 20.5±0.4cm compared with baseline values of 20.19cm and 20.79cm, respectively. Range shifter field symmetry had an average of less 1% for both in-plane and cross plane measurements. Conclusion: All machine metrics over the past 6 months have proved to be stable. Although, some averages are outside the baseline measurement they are within 1% tolerance and the deviation across all measurements is minimal.« less
Intra- and Interobserver Variability of Cochlear Length Measurements in Clinical CT.
Iyaniwura, John E; Elfarnawany, Mai; Riyahi-Alam, Sadegh; Sharma, Manas; Kassam, Zahra; Bureau, Yves; Parnes, Lorne S; Ladak, Hanif M; Agrawal, Sumit K
2017-07-01
The cochlear A-value measurement exhibits significant inter- and intraobserver variability, and its accuracy is dependent on the visualization method in clinical computed tomography (CT) images of the cochlea. An accurate estimate of the cochlear duct length (CDL) can be used to determine electrode choice, and frequency map the cochlea based on the Greenwood equation. Studies have described estimating the CDL using a single A-value measurement, however the observer variability has not been assessed. Clinical and micro-CT images of 20 cadaveric cochleae were acquired. Four specialists measured A-values on clinical CT images using both standard views and multiplanar reconstructed (MPR) views. Measurements were repeated to assess for intraobserver variability. Observer variabilities were evaluated using intra-class correlation and absolute differences. Accuracy was evaluated by comparison to the gold standard micro-CT images of the same specimens. Interobserver variability was good (average absolute difference: 0.77 ± 0.42 mm) using standard views and fair (average absolute difference: 0.90 ± 0.31 mm) using MPR views. Intraobserver variability had an average absolute difference of 0.31 ± 0.09 mm for the standard views and 0.38 ± 0.17 mm for the MPR views. MPR view measurements were more accurate than standard views, with average relative errors of 9.5 and 14.5%, respectively. There was significant observer variability in A-value measurements using both the standard and MPR views. Creating the MPR views increased variability between experts, however MPR views yielded more accurate results. Automated A-value measurement algorithms may help to reduce variability and increase accuracy in the future.
Lockie, Robert G; Schultz, Adrian B; Callaghan, Samuel J; Jeffriess, Matthew D; Berry, Simon P
2013-01-01
Field sport coaches must use reliable and valid tests to assess change-of-direction speed in their athletes. Few tests feature linear sprinting with acute change- of-direction maneuvers. The Change-of-Direction and Acceleration Test (CODAT) was designed to assess field sport change-of-direction speed, and includes a linear 5-meter (m) sprint, 45° and 90° cuts, 3- m sprints to the left and right, and a linear 10-m sprint. This study analyzed the reliability and validity of this test, through comparisons to 20-m sprint (0-5, 0-10, 0-20 m intervals) and Illinois agility run (IAR) performance. Eighteen Australian footballers (age = 23.83 ± 7.04 yrs; height = 1.79 ± 0.06 m; mass = 85.36 ± 13.21 kg) were recruited. Following familiarization, subjects completed the 20-m sprint, CODAT, and IAR in 2 sessions, 48 hours apart. Intra-class correlation coefficients (ICC) assessed relative reliability. Absolute reliability was analyzed through paired samples t-tests (p ≤ 0.05) determining between-session differences. Typical error (TE), coefficient of variation (CV), and differences between the TE and smallest worthwhile change (SWC), also assessed absolute reliability and test usefulness. For the validity analysis, Pearson's correlations (p ≤ 0.05) analyzed between-test relationships. Results showed no between-session differences for any test (p = 0.19-0.86). CODAT time averaged ~6 s, and the ICC and CV equaled 0.84 and 3.0%, respectively. The homogeneous sample of Australian footballers meant that the CODAT's TE (0.19 s) exceeded the usual 0.2 x standard deviation (SD) SWC (0.10 s). However, the CODAT is capable of detecting moderate performance changes (SWC calculated as 0.5 x SD = 0.25 s). There was a near perfect correlation between the CODAT and IAR (r = 0.92), and very large correlations with the 20-m sprint (r = 0.75-0.76), suggesting that the CODAT was a valid change-of-direction speed test. Due to movement specificity, the CODAT has value for field sport assessment. Key pointsThe change-of-direction and acceleration test (CODAT) was designed specifically for field sport athletes from specific speed research, and data derived from time-motion analyses of sports such as rugby union, soccer, and Australian football. The CODAT features a linear 5-meter (m) sprint, 45° and 90° cuts and 3-m sprints to the left and right, and a linear 10-m sprint.The CODAT was found to be a reliable change-of-direction speed assessment when considering intra-class correlations between two testing sessions, and the coefficient of variation between trials. A homogeneous sample of Australian footballers resulted in absolute reliability limitations when considering differences between the typical error and smallest worthwhile change. However, the CODAT will detect moderate (0.5 times the test's standard deviation) changes in performance.The CODAT correlated with the Illinois agility run, highlighting that it does assess change-of-direction speed. There were also significant relationships with short sprint performance (i.e. 0-5 m and 0-10 m), demonstrating that linear acceleration is assessed within the CODAT, without the extended duration and therefore metabolic limitations of the IAR. Indeed, the average duration of the test (~6 seconds) is field sport-specific. Therefore, the CODAT could be used as an assessment of change-of-direction speed in field sport athletes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korhonen, Juha, E-mail: juha.p.korhonen@hus.fi; Kapanen, Mika; Department of Oncology, Helsinki University Central Hospital, POB-180, 00029 HUS
Purpose: The lack of electron density information in magnetic resonance images (MRI) poses a major challenge for MRI-based radiotherapy treatment planning (RTP). In this study the authors convert MRI intensity values into Hounsfield units (HUs) in the male pelvis and thus enable accurate MRI-based RTP for prostate cancer patients with varying tissue anatomy and body fat contents. Methods: T{sub 1}/T{sub 2}*-weighted MRI intensity values and standard computed tomography (CT) image HUs in the male pelvis were analyzed using image data of 10 prostate cancer patients. The collected data were utilized to generate a dual model HU conversion technique from MRImore » intensity values of the single image set separately within and outside of contoured pelvic bones. Within the bone segment local MRI intensity values were converted to HUs by applying a second-order polynomial model. This model was tuned for each patient by two patient-specific adjustments: MR signal normalization to correct shifts in absolute intensity level and application of a cutoff value to accurately represent low density bony tissue HUs. For soft tissues, such as fat and muscle, located outside of the bone contours, a threshold-based segmentation method without requirements for any patient-specific adjustments was introduced to convert MRI intensity values into HUs. The dual model HU conversion technique was implemented by constructing pseudo-CT images for 10 other prostate cancer patients. The feasibility of these images for RTP was evaluated by comparing HUs in the generated pseudo-CT images with those in standard CT images, and by determining deviations in MRI-based dose distributions compared to those in CT images with 7-field intensity modulated radiation therapy (IMRT) with the anisotropic analytical algorithm and 360° volumetric-modulated arc therapy (VMAT) with the Voxel Monte Carlo algorithm. Results: The average HU differences between the constructed pseudo-CT images and standard CT images of each test patient ranged from −2 to 5 HUs and from 22 to 78 HUs in soft and bony tissues, respectively. The average local absolute value differences were 11 HUs in soft tissues and 99 HUs in bones. The planning target volume doses (volumes 95%, 50%, 5%) in the pseudo-CT images were within 0.8% compared to those in CT images in all of the 20 treatment plans. The average deviation was 0.3%. With all the test patients over 94% (IMRT) and 92% (VMAT) of dose points within body (lower than 10% of maximum dose suppressed) passed the 1 mm and 1% 2D gamma index criterion. The statistical tests (t- and F-tests) showed significantly improved (p ≤ 0.05) HU and dose calculation accuracies with the soft tissue conversion method instead of homogeneous representation of these tissues in MRI-based RTP images. Conclusions: This study indicates that it is possible to construct high quality pseudo-CT images by converting the intensity values of a single MRI series into HUs in the male pelvis, and to use these images for accurate MRI-based prostate RTP dose calculations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korhonen, Juha, E-mail: juha.p.korhonen@hus.fi; Department of Oncology, Helsinki University Central Hospital, POB-180, 00029 HUS; Kapanen, Mika
2014-01-15
Purpose: The lack of electron density information in magnetic resonance images (MRI) poses a major challenge for MRI-based radiotherapy treatment planning (RTP). In this study the authors convert MRI intensity values into Hounsfield units (HUs) in the male pelvis and thus enable accurate MRI-based RTP for prostate cancer patients with varying tissue anatomy and body fat contents. Methods: T{sub 1}/T{sub 2}*-weighted MRI intensity values and standard computed tomography (CT) image HUs in the male pelvis were analyzed using image data of 10 prostate cancer patients. The collected data were utilized to generate a dual model HU conversion technique from MRImore » intensity values of the single image set separately within and outside of contoured pelvic bones. Within the bone segment local MRI intensity values were converted to HUs by applying a second-order polynomial model. This model was tuned for each patient by two patient-specific adjustments: MR signal normalization to correct shifts in absolute intensity level and application of a cutoff value to accurately represent low density bony tissue HUs. For soft tissues, such as fat and muscle, located outside of the bone contours, a threshold-based segmentation method without requirements for any patient-specific adjustments was introduced to convert MRI intensity values into HUs. The dual model HU conversion technique was implemented by constructing pseudo-CT images for 10 other prostate cancer patients. The feasibility of these images for RTP was evaluated by comparing HUs in the generated pseudo-CT images with those in standard CT images, and by determining deviations in MRI-based dose distributions compared to those in CT images with 7-field intensity modulated radiation therapy (IMRT) with the anisotropic analytical algorithm and 360° volumetric-modulated arc therapy (VMAT) with the Voxel Monte Carlo algorithm. Results: The average HU differences between the constructed pseudo-CT images and standard CT images of each test patient ranged from −2 to 5 HUs and from 22 to 78 HUs in soft and bony tissues, respectively. The average local absolute value differences were 11 HUs in soft tissues and 99 HUs in bones. The planning target volume doses (volumes 95%, 50%, 5%) in the pseudo-CT images were within 0.8% compared to those in CT images in all of the 20 treatment plans. The average deviation was 0.3%. With all the test patients over 94% (IMRT) and 92% (VMAT) of dose points within body (lower than 10% of maximum dose suppressed) passed the 1 mm and 1% 2D gamma index criterion. The statistical tests (t- and F-tests) showed significantly improved (p ≤ 0.05) HU and dose calculation accuracies with the soft tissue conversion method instead of homogeneous representation of these tissues in MRI-based RTP images. Conclusions: This study indicates that it is possible to construct high quality pseudo-CT images by converting the intensity values of a single MRI series into HUs in the male pelvis, and to use these images for accurate MRI-based prostate RTP dose calculations.« less
Mammographic Density Phenotypes and Risk of Breast Cancer: A Meta-analysis
Graff, Rebecca E.; Ursin, Giske; dos Santos Silva, Isabel; McCormack, Valerie; Baglietto, Laura; Vachon, Celine; Bakker, Marije F.; Giles, Graham G.; Chia, Kee Seng; Czene, Kamila; Eriksson, Louise; Hall, Per; Hartman, Mikael; Warren, Ruth M. L.; Hislop, Greg; Chiarelli, Anna M.; Hopper, John L.; Krishnan, Kavitha; Li, Jingmei; Li, Qing; Pagano, Ian; Rosner, Bernard A.; Wong, Chia Siong; Scott, Christopher; Stone, Jennifer; Maskarinec, Gertraud; Boyd, Norman F.; van Gils, Carla H.
2014-01-01
Background Fibroglandular breast tissue appears dense on mammogram, whereas fat appears nondense. It is unclear whether absolute or percentage dense area more strongly predicts breast cancer risk and whether absolute nondense area is independently associated with risk. Methods We conducted a meta-analysis of 13 case–control studies providing results from logistic regressions for associations between one standard deviation (SD) increments in mammographic density phenotypes and breast cancer risk. We used random-effects models to calculate pooled odds ratios and 95% confidence intervals (CIs). All tests were two-sided with P less than .05 considered to be statistically significant. Results Among premenopausal women (n = 1776 case patients; n = 2834 control subjects), summary odds ratios were 1.37 (95% CI = 1.29 to 1.47) for absolute dense area, 0.78 (95% CI = 0.71 to 0.86) for absolute nondense area, and 1.52 (95% CI = 1.39 to 1.66) for percentage dense area when pooling estimates adjusted for age, body mass index, and parity. Corresponding odds ratios among postmenopausal women (n = 6643 case patients; n = 11187 control subjects) were 1.38 (95% CI = 1.31 to 1.44), 0.79 (95% CI = 0.73 to 0.85), and 1.53 (95% CI = 1.44 to 1.64). After additional adjustment for absolute dense area, associations between absolute nondense area and breast cancer became attenuated or null in several studies and summary odds ratios became 0.82 (95% CI = 0.71 to 0.94; P heterogeneity = .02) for premenopausal and 0.85 (95% CI = 0.75 to 0.96; P heterogeneity < .01) for postmenopausal women. Conclusions The results suggest that percentage dense area is a stronger breast cancer risk factor than absolute dense area. Absolute nondense area was inversely associated with breast cancer risk, but it is unclear whether the association is independent of absolute dense area. PMID:24816206
Accuracy of open-source software segmentation and paper-based printed three-dimensional models.
Szymor, Piotr; Kozakiewicz, Marcin; Olszewski, Raphael
2016-02-01
In this study, we aimed to verify the accuracy of models created with the help of open-source Slicer 3.6.3 software (Surgical Planning Lab, Harvard Medical School, Harvard University, Boston, MA, USA) and the Mcor Matrix 300 paper-based 3D printer. Our study focused on the accuracy of recreating the walls of the right orbit of a cadaveric skull. Cone beam computed tomography (CBCT) of the skull was performed (0.25-mm pixel size, 0.5-mm slice thickness). Acquired DICOM data were imported into Slicer 3.6.3 software, where segmentation was performed. A virtual model was created and saved as an .STL file and imported into Netfabb Studio professional 4.9.5 software. Three different virtual models were created by cutting the original file along three different planes (coronal, sagittal, and axial). All models were printed with a Selective Deposition Lamination Technology Matrix 300 3D printer using 80 gsm A4 paper. The models were printed so that their cutting plane was parallel to the paper sheets creating the model. Each model (coronal, sagittal, and axial) consisted of three separate parts (∼200 sheets of paper each) that were glued together to form a final model. The skull and created models were scanned with a three-dimensional (3D) optical scanner (Breuckmann smart SCAN) and were saved as .STL files. Comparisons of the orbital walls of the skull, the virtual model, and each of the three paper models were carried out with GOM Inspect 7.5SR1 software. Deviations measured between the models analysed were presented in the form of a colour-labelled map and covered with an evenly distributed network of points automatically generated by the software. An average of 804.43 ± 19.39 points for each measurement was created. Differences measured in each point were exported as a .csv file. The results were statistically analysed using Statistica 10, with statistical significance set at p < 0.05. The average number of points created on models for each measurement was 804.43 ± 19.39; however, deviation in some of the generated points could not be calculated, and those points were excluded from further calculations. From 94% to 99% of the measured absolute deviations were <1 mm. The mean absolute deviation between the skull and virtual model was 0.15 ± 0.11 mm, between the virtual and printed models was 0.15 ± 0.12 mm, and between the skull and printed models was 0.24 ± 0.21 mm. Using the optical scanner and specialized inspection software for measurements of accuracy of the created parts is recommended, as it allows one not only to measure 2-dimensional distances between anatomical points but also to perform more clinically suitable comparisons of whole surfaces. However, it requires specialized software and a very accurate scanner in order to be useful. Threshold-based, manually corrected segmentation of orbital walls performed with 3D Slicer software is accurate enough to be used for creating a virtual model of the orbit. The accuracy of the paper-based Mcor Matrix 300 3D printer is comparable to those of other commonly used 3-dimensional printers and allows one to create precise anatomical models for clinical use. The method of dividing the model into smaller parts and sticking them together seems to be quite accurate, although we recommend it only for creating small, solid models with as few parts as possible to minimize shift associated with gluing. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Autonomous cryogenic sapphire oscillators employing low vibration pulse-tube cryocoolers at NMIJ
NASA Astrophysics Data System (ADS)
Ikegami, Takeshi; Watabe, Ken-ichi; Yanagimachi, Shinya; Takamizawa, Akifumi; Hartnett, John G.
2016-06-01
Two liquid-helium-cooled cryogenic sapphire-resonator oscillators (CSOs), have been modified to operate using cryo-refrigerators and low-vibration cryostats. The Allan deviation of the first CSO was evaluated to be better than 2 x 10-15 for averaging times of 1 s to 30 000 s, which is better than that of the original liquid helium cooled CSO. The Allan deviation of the second CSO is better than 4 x 10-15 from 1 s to 6 000 s averaging time.
NASA Technical Reports Server (NTRS)
Anspaugh, B. E.; Miyahira, T. F.; Weiss, R. S.
1979-01-01
Computed statistical averages and standard deviations with respect to the measured cells for each intensity temperature measurement condition are presented. Display averages and standard deviations of the cell characteristics in a two dimensional array format are shown: one dimension representing incoming light intensity, and another, the cell temperature. Programs for calculating the temperature coefficients of the pertinent cell electrical parameters are presented, and postirradiation data are summarized.
Measuring Time-Averaged Blood Pressure
NASA Technical Reports Server (NTRS)
Rothman, Neil S.
1988-01-01
Device measures time-averaged component of absolute blood pressure in artery. Includes compliant cuff around artery and external monitoring unit. Ceramic construction in monitoring unit suppresses ebb and flow of pressure-transmitting fluid in sensor chamber. Transducer measures only static component of blood pressure.
Who's biased? A meta-analysis of buyer-seller differences in the pricing of lotteries.
Yechiam, Eldad; Ashby, Nathaniel J S; Pachur, Thorsten
2017-05-01
A large body of empirical research has examined the impact of trading perspective on pricing of consumer products, with the typical finding being that selling prices exceed buying prices (i.e., the endowment effect). Using a meta-analytic approach, we examine to what extent the endowment effect also emerges in the pricing of monetary lotteries. As monetary lotteries have a clearly defined normative value, we also assess whether one trading perspective is more biased than the other. We consider several indicators of bias: absolute deviation from expected values, rank correlation with expected values, overall variance, and per-unit variance. The meta-analysis, which includes 35 articles, indicates that selling prices considerably exceed buying prices (Cohen's d = 0.58). Importantly, we also find that selling prices deviate less from the lotteries' expected values than buying prices, both in absolute and in relative terms. Selling prices also exhibit lower variance per unit. Hierarchical Bayesian modeling with cumulative prospect theory indicates that buyers have lower probability sensitivity and a more pronounced response bias. The finding that selling prices are more in line with normative standards than buying prices challenges the prominent account whereby sellers' valuations are upward biased due to loss aversion, and supports alternative theoretical accounts. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Inter-laboratory validation of bioaccessibility testing for metals.
Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R
2014-10-01
Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.
Cozzi, Bruno; De Giorgio, Andrea; Peruffo, A; Montelli, S; Panin, M; Bombardi, C; Grandis, A; Pirone, A; Zambenedetti, P; Corain, L; Granato, Alberto
2017-08-01
The architecture of the neocortex classically consists of six layers, based on cytological criteria and on the layout of intra/interlaminar connections. Yet, the comparison of cortical cytoarchitectonic features across different species proves overwhelmingly difficult, due to the lack of a reliable model to analyze the connection patterns of neuronal ensembles forming the different layers. We first defined a set of suitable morphometric cell features, obtained in digitized Nissl-stained sections of the motor cortex of the horse, chimpanzee, and crab-eating macaque. We then modeled them using a quite general non-parametric data representation model, showing that the assessment of neuronal cell complexity (i.e., how a given cell differs from its neighbors) can be performed using a suitable measure of statistical dispersion such as the mean absolute deviation-mean absolute deviation (MAD). Along with the non-parametric combination and permutation methodology, application of MAD allowed not only to estimate, but also to compare and rank the motor cortical complexity across different species. As to the instances presented in this paper, we show that the pyramidal layers of the motor cortex of the horse are far more irregular than those of primates. This feature could be related to the different organizations of the motor system in monodactylous mammals.
Mendiburu, Andrés Z; de Carvalho, João A; Coronado, Christian R
2015-03-21
Estimation of the lower flammability limits of C-H compounds at 25 °C and 1 atm; at moderate temperatures and in presence of diluent was the objective of this study. A set of 120 C-H compounds was divided into a correlation set and a prediction set of 60 compounds each. The absolute average relative error for the total set was 7.89%; for the correlation set, it was 6.09%; and for the prediction set it was 9.68%. However, it was shown that by considering different sources of experimental data the values were reduced to 6.5% for the prediction set and to 6.29% for the total set. The method showed consistency with Le Chatelier's law for binary mixtures of C-H compounds. When tested for a temperature range from 5 °C to 100 °C, the absolute average relative errors were 2.41% for methane; 4.78% for propane; 0.29% for iso-butane and 3.86% for propylene. When nitrogen was added, the absolute average relative errors were 2.48% for methane; 5.13% for propane; 0.11% for iso-butane and 0.15% for propylene. When carbon dioxide was added, the absolute relative errors were 1.80% for methane; 5.38% for propane; 0.86% for iso-butane and 1.06% for propylene. Copyright © 2014 Elsevier B.V. All rights reserved.
Allan deviation analysis of financial return series
NASA Astrophysics Data System (ADS)
Hernández-Pérez, R.
2012-05-01
We perform a scaling analysis for the return series of different financial assets applying the Allan deviation (ADEV), which is used in the time and frequency metrology to characterize quantitatively the stability of frequency standards since it has demonstrated to be a robust quantity to analyze fluctuations of non-stationary time series for different observation intervals. The data used are opening price daily series for assets from different markets during a time span of around ten years. We found that the ADEV results for the return series at short scales resemble those expected for an uncorrelated series, consistent with the efficient market hypothesis. On the other hand, the ADEV results for absolute return series for short scales (first one or two decades) decrease following approximately a scaling relation up to a point that is different for almost each asset, after which the ADEV deviates from scaling, which suggests that the presence of clustering, long-range dependence and non-stationarity signatures in the series drive the results for large observation intervals.
Daily Deviations in Anger, Guilt, and Sympathy: A Developmental Diary Study of Aggression.
Colasante, Tyler; Zuffianò, Antonio; Malti, Tina
2016-11-01
With a diary study of 4- and 8-year-olds, we tested the association between daily deviations in anger and aggressive behavior, and whether this link was moderated by feelings of guilt and sympathy. Caregivers reported their children's anger and aggression for 10 consecutive days (470 records; N = 80, 53 % girls). To calculate daily anger deviations from average anger levels, we subtracted each child's average anger score (i.e., across 10 days) from his/her daily anger scores. Children reported their guilty feelings in response to vignettes depicting intentional harm, as well as their dispositional sympathy levels. Multilevel modeling indicated that within-child spikes in daily anger were associated with more aggression, above and beyond between-child differences in average anger levels. However, this association was weaker for children who reported higher levels of guilt. Sympathy did not moderate the anger-aggression link. We discuss potential implications for affective-developmental models of aggression and interventions that target anger-related aggression.
Kook, Michael S; Cho, Hyun-soo; Seong, Mincheol; Choi, Jaewan
2005-11-01
To evaluate the ability of scanning laser polarimetry parameters and a novel deviation map algorithm to discriminate between healthy and early glaucomatous eyes with localized visual field (VF) defects confined to one hemifield. Prospective case-control study. Seventy glaucomatous eyes with localized VF defects and 66 normal controls. A Humphrey field analyzer 24-2 full-threshold test and scanning laser polarimetry with variable corneal compensation were used. We assessed the sensitivity and specificity of scanning laser polarimetry parameters, sensitivity and cutoff values for scanning laser polarimetry deviation map algorithms at different specificity values (80%, 90%, and 95%) in the detection of glaucoma, and correlations between the algorithms of scanning laser polarimetry and of the pattern deviation derived from Humphrey field analyzer testing. There were significant differences between the glaucoma group and normal subjects in the mean parametric values of the temporal, superior, nasal, inferior, temporal (TSNIT) average, superior average, inferior average, and TSNIT standard deviation (SD) (P<0.05). The sensitivity and specificity of each scanning laser polarimetry variable was as follows: TSNIT, 44.3% (95% confidence interval [CI], 39.8%-49.8%) and 100% (95.4%-100%); superior average, 30% (25.5%-34.5%) and 97% (93.5%-100%); inferior average, 45.7% (42.2%-49.2%) and 100% (95.8%-100%); and TSNIT SD, 30% (25.9%-34.1%) and 97% (93.2%-100%), respectively (when abnormal was defined as P<0.05). Based on nerve fiber indicator cutoff values of > or =30 and > or =51 to indicate glaucoma, sensitivities were 54.3% (50.1%-58.5%) and 10% (6.4%-13.6%), and specificities were 97% (93.2%-100%) and 100% (95.8%-100%), respectively. The range of areas under the receiver operating characteristic curves using the scanning laser polarimetry deviation map algorithm was 0.790 to 0.879. Overall sensitivities combining each probability scale and severity score at 80%, 90%, and 95% specificities were 90.0% (95% CI, 86.4%-93.6%), 71.4% (67.4%-75.4%), and 60.0% (56.2%-63.8%), respectively. There was a statistically significant correlation between the scanning laser polarimetry severity score and the VF severity score (R2 = 0.360, P<0.001). Scanning laser polarimetry parameters may not be sufficiently sensitive to detect glaucomatous patients with localized VF damage. Our algorithm using the scanning laser polarimetry deviation map may enhance the understanding of scanning laser polarimetry printouts in terms of the locality, deviation size, and severity of localized retinal nerve fiber layer defects in eyes with localized VF loss.
Grundstein, Andrew J; Hosokawa, Yuri; Casa, Douglas J
2018-01-01
Weather-based activity modification in athletics is an important way to minimize heat illnesses. However, many commonly used heat-safety guidelines include a uniform set of heat-stress thresholds that do not account for geographic differences in acclimatization. To determine if heat-related fatalities among American football players occurred on days with unusually stressful weather conditions based on the local climate and to assess the need for regional heat-safety guidelines. Cross-sectional study. Data from incidents of fatal exertional heat stroke (EHS) in American football players were obtained from the National Center for Catastrophic Sport Injury Research and the Korey Stringer Institute. Sixty-one American football players at all levels of competition with fatal EHSs from 1980 to 2014. We used the wet bulb globe temperature (WBGT) and a z-score WBGT standardized to local climate conditions from 1991 to 2010 to assess the absolute and relative magnitudes of heat stress, respectively. We observed a poleward decrease in exposure WBGTs during fatal EHSs. In milder climates, 80% of cases occurred at above-average WBGTs, and 50% occurred at WBGTs greater than 1 standard deviation from the long-term mean; however, in hotter climates, half of the cases occurred at near average or below average WBGTs. The combination of lower exposure WBGTs and frequent extreme climatic values in milder climates during fatal EHSs indicates the need for regional activity-modification guidelines with lower, climatically appropriate weather-based thresholds. Established activity-modification guidelines, such as those from the American College of Sports Medicine, work well in the hotter climates, such as the southern United States, where hot and humid weather conditions are common.
Simulation and Analysis of Topographic Effect on Land Surface Albedo over Mountainous Areas
NASA Astrophysics Data System (ADS)
Hao, D.; Wen, J.; Xiao, Q.
2017-12-01
Land surface albedo is one of the significant geophysical variables affecting the Earth's climate and controlling the surface radiation budget. Topography leads to the formation of shadows and the redistribution of incident radiation, which complicates the modeling and estimation of the land surface albedo. Some studies show that neglecting the topography effect may lead to significant bias in estimating the land surface albedo for the sloping terrain. However, for the composite sloping terrain, the topographic effects on the albedo remain unclear. Accurately estimating the sub-topographic effect on the land surface albedo over the composite sloping terrain presents a challenge for remote sensing modeling and applications. In our study, we focus on the development of a simplified estimation method for land surface albedo including black-sky albedo (BSA) and white-sky albedo (WSA) of the composite sloping terrain at a kilometer scale based on the fine scale DEM (30m) and quantitatively investigate and understand the topographic effects on the albedo. The albedo is affected by various factors such as solar zenith angle (SZA), solar azimuth angle (SAA), shadows, terrain occlusion, and slope and aspect distribution of the micro-slopes. When SZA is 30°, the absolute and relative deviations between the BSA of flat terrain and that of rugged terrain reaches 0.12 and 50%, respectively. When the mean slope of the terrain is 30.63° and SZA=30°, the absolute deviation of BSA caused by SAA can reach 0.04. The maximal relative and relative deviation between the WSA of flat terrain and that of rugged terrain reaches 0.08 and 50%. These results demonstrate that the topographic effect has to be taken into account in the albedo estimation.
Gödel, Tarski, Turing and the Conundrum of Free Will
NASA Astrophysics Data System (ADS)
Nayakar, Chetan S. Mandayam; Srikanth, R.
2014-07-01
The problem of defining and locating free will (FW) in physics is studied. On the basis of logical paradoxes, we argue that FW has a metatheoretic character, like the concept of truth in Tarski's undefinability theorem. Free will exists relative to a base theory if there is freedom to deviate from the deterministic or indeterministic dynamics in the theory, with the deviations caused by parameters (representing will) in the meta-theory. By contrast, determinism and indeterminism do not require meta-theoretic considerations in their formalization, making FW a fundamentally new causal primitive. FW exists relative to the meta-theory if there is freedom for deviation, due to higher-order causes. Absolute free will, which corresponds to our intuitive introspective notion of free will, exists if this meta-theoretic hierarchy is infinite. We argue that this hierarchy corresponds to higher levels of uncomputability. In other words, at any finitely high order in the hierarchy, there are uncomputable deviations from the law at that order. Applied to the human condition, the hierarchy corresponds to deeper levels of the subconscious or unconscious mind. Possible ramifications of our model for physics, neuroscience and artificial intelligence (AI) are briefly considered.
NASA Astrophysics Data System (ADS)
Schutt, D.; Witt, D. R.; Aster, R. C.; Freymueller, J.; Cubley, J. F.
2017-12-01
Shear wave splitting results from the Northern Cordillera and surroundings will be presented. This complex tectonic setting contains a subduction zone responding to the Yakutat Indenter, an oceanic plateau fragment, a slab window under the Yukon Territory, and the actively uplifting Mackenzie Mountains. A particular goal of this project is to understand whether asthenospheric tractions play a significant role in Mackenzie Mountain uplift. Using a new method for calculating station-averaged splitting parameters, we have analyzed stations that span a large part of the region and therefore can see the variation in splitting parameters from the dynamic NA-PA subduction zone to the stable Slave Craton. Like other shear wave splitting studies in the Northern Cordillera, we find abrupt changes in fast axis direction along the continental margin, while the continental interior displays more coherent splitting parameters. This study is also the first to look at data from a recent deployment through center of the Mackenzie Mountains. Northeast of the Tintina Fault, we find average fast axes directions that are very close to the absolute NA plate motion but our large deviations from event to event suggest that there is some crustal anisotropy and/or dipping structure present. This observation appears to support the idea of a lower crustal décollement that has been put forth by Mazzoti and Hyndman [2002]. These results serve as a broad regional overview of mantle anisotropy and may also shed light on frozen lithospheric deformation.
Chan, B H; Leung, Y Y
2018-04-01
The comparison of serial radiographs and clinical photographs is considered the current accepted standard for the diagnosis of active condylar hyperplasia in patients with facial asymmetry. Single photon emission computed tomography (SPECT) has recently been proposed as an alternative method. SPECT can be interpreted using three reported methods absolute difference in uptake, uptake ratio, and relative uptake. SPECT findings were compared to those from serial comparisons of radiographs and clinical photographs taken at the time of SPECT and a year later; the sensitivities and specificities were determined. Two hundred patient scans were evaluated. Thirty-four patients showed active growth on serial growth assessment. On comparison with serial growth assessment, the sensitivity and specificity of the three methods ranged between 32.4% and 67.6%, and 36.1% and 78.3%, respectively. Analysis using receiver operating characteristic (ROC) curves revealed area under the curve (AUC) values of <0.58. The average age (mean±standard deviation) of patients with active growth was 18.6±2.8 years, and average growth in the anteroposterior, vertical, and transverse directions was 0.94±0.91mm, 0.88±0.86mm, and 1.4±0.66 mm, respectively. With such low sensitivity and specificity values, it is not justifiable to use SPECT in place of serial growth assessment for the determination of condylar growth status. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Usta, Murat; Aral, Hale; Mete Çilingirtürk, Ahmet; Kural, Alev; Topaç, Ibrahim; Semerci, Tuna; Hicri Köseoğlu, Mehmet
2016-11-01
Average of normals (AON) is a quality control procedure that is sensitive only to systematic errors that can occur in an analytical process in which patient test results are used. The aim of this study was to develop an alternative model in order to apply the AON quality control procedure to datasets that include qualitative values below limit of detection (LoD). The reported patient test results for tumor markers, such as CA 15-3, CA 125, and CA 19-9, analyzed by two instruments, were retrieved from the information system over a period of 5 months, using the calibrator and control materials with the same lot numbers. The median as a measure of central tendency and the median absolute deviation (MAD) as a measure of dispersion were used for the complementary model of AON quality control procedure. The u bias values, which were determined for the bias component of the measurement uncertainty, were partially linked to the percentages of the daily median values of the test results that fall within the control limits. The results for these tumor markers, in which lower limits of reference intervals are not medically important for clinical diagnosis and management, showed that the AON quality control procedure, using the MAD around the median, can be applied for datasets including qualitative values below LoD.
Microcephaly: general considerations and aids to nosology.
Opitz, J M; Holt, M C
1990-01-01
Microcephaly is defined as an occipito-frontal head circumference (OFC) 2 or more standard deviations below the mean for age and sex using the new Roche et al. [Pediatrics 1987;79:706-712] charts, and corrected for parental OFC by the method of Weaver and Christian [J Pediatr 1980;96:990-994]. "Relative" microcephaly, i.e., a small head on a small child, may be associated with a much better intellectual prognosis than absolute microcephaly, although the average IQ of children with absolute microcephaly ascertained in a normal school system is normal when compared with that of appropriate control children. "Primary" microcephaly means an abnormal OFC at birth (corrected for gestational age and length), and "secondary" microcephaly a normal birth OFC with later, acquired microcephaly due to deceleration of brain growth reflecting infection, trauma, intoxication, metabolic disease, the Rett syndrome, or a true CNS degenerative disease. Some cases of syndromal microcephaly may be associated with normal intelligence including some "primordial dwarfs," children with Dubowitz syndrome, FAS, mild SC-Roberts syndrome, and an occasional Brachmann-de Lange individual. The nosology of (syndromal) microcephaly is extraordinarily complex and requires the assistance of special library resources and information retrieval expertise. At a minimum, it requires McKusick's Catalog of Mendelian Inheritance in Man (MIM); however, we find that our work is greatly enhanced by recently developed electronic databases such as MIM-online (OMIM), POSSUM, SYNDROME, and MEDLINE, as well. Three groups of syndromal and non-syndromal microcephaly are discussed selectively in order to illustrate the marvels of pleiotropy in human development and its abnormalities and the difficulties encountered in splitting and lumping entities with overlapping manifestations.
Uncertainties in Climatological Seawater Density Calculations
NASA Astrophysics Data System (ADS)
Dai, Hao; Zhang, Xining
2018-03-01
In most applications, with seawater conductivity, temperature, and pressure data measured in situ by various observation instruments e.g., Conductivity-Temperature-Depth instruments (CTD), the density which has strong ties to ocean dynamics and so on is computed according to equations of state for seawater. This paper, based on density computational formulae in the Thermodynamic Equation of Seawater 2010 (TEOS-10), follows the Guide of the expression of Uncertainty in Measurement (GUM) and assesses the main sources of uncertainties. By virtue of climatological decades-average temperature/Practical Salinity/pressure data sets in the global ocean provided by the National Oceanic and Atmospheric Administration (NOAA), correlation coefficients between uncertainty sources are determined and the combined standard uncertainties uc>(ρ>) in seawater density calculations are evaluated. For grid points in the world ocean with 0.25° resolution, the standard deviations of uc>(ρ>) in vertical profiles cover the magnitude order of 10-4 kg m-3. The uc>(ρ>) means in vertical profiles of the Baltic Sea are about 0.028kg m-3 due to the larger scatter of Absolute Salinity anomaly. The distribution of the uc>(ρ>) means in vertical profiles of the world ocean except for the Baltic Sea, which covers the range of >(0.004,0.01>) kg m-3, is related to the correlation coefficient r>(SA,p>) between Absolute Salinity SA and pressure p. The results in the paper are based on sensors' measuring uncertainties of high accuracy CTD. Larger uncertainties in density calculations may arise if connected with lower sensors' specifications. This work may provide valuable uncertainty information required for reliability considerations of ocean circulation and global climate models.
Chen, Yasheng; Juttukonda, Meher; Su, Yi; Benzinger, Tammie; Rubin, Brian G.; Lee, Yueh Z.; Lin, Weili; Shen, Dinggang; Lalush, David
2015-01-01
Purpose To develop a positron emission tomography (PET) attenuation correction method for brain PET/magnetic resonance (MR) imaging by estimating pseudo computed tomographic (CT) images from T1-weighted MR and atlas CT images. Materials and Methods In this institutional review board–approved and HIPAA-compliant study, PET/MR/CT images were acquired in 20 subjects after obtaining written consent. A probabilistic air segmentation and sparse regression (PASSR) method was developed for pseudo CT estimation. Air segmentation was performed with assistance from a probabilistic air map. For nonair regions, the pseudo CT numbers were estimated via sparse regression by using atlas MR patches. The mean absolute percentage error (MAPE) on PET images was computed as the normalized mean absolute difference in PET signal intensity between a method and the reference standard continuous CT attenuation correction method. Friedman analysis of variance and Wilcoxon matched-pairs tests were performed for statistical comparison of MAPE between the PASSR method and Dixon segmentation, CT segmentation, and population averaged CT atlas (mean atlas) methods. Results The PASSR method yielded a mean MAPE ± standard deviation of 2.42% ± 1.0, 3.28% ± 0.93, and 2.16% ± 1.75, respectively, in the whole brain, gray matter, and white matter, which were significantly lower than the Dixon, CT segmentation, and mean atlas values (P < .01). Moreover, 68.0% ± 16.5, 85.8% ± 12.9, and 96.0% ± 2.5 of whole-brain volume had within ±2%, ±5%, and ±10% percentage error by using PASSR, respectively, which was significantly higher than other methods (P < .01). Conclusion PASSR outperformed the Dixon, CT segmentation, and mean atlas methods by reducing PET error owing to attenuation correction. © RSNA, 2014 PMID:25521778
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zerouali, K; Aubry, J; Doucet, R
2016-06-15
Purpose: To implement the new EBT-XD Gafchromic films for accurate dosimetric and geometric validation of stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) CyberKnife (CK) patient specific QA. Methods: Film calibration was performed using a triplechannel film analysis on an Epson 10000XL scanner. Calibration films were irradiated using a Varian Clinac 21EX flattened beam (0 to 20 Gy), to ensure sufficient dose homogeneity. Films were scanned to a resolution of 0.3 mm, 24 hours post irradiation following a well-defined protocol. A set of 12 QA was performed for several types of CK plans: trigeminal neuralgia, brain metastasis, prostate andmore » lung tumors. A custom made insert for the CK head phantom has been manufactured to yield an accurate measured to calculated dose registration. When the high dose region was large enough, absolute dose was also measured with an ionization chamber. Dose calculation is performed using MultiPlan Ray-tracing algorithm for all cases since the phantom is mostly made from near water-equivalent plastic. Results: Good agreement (<2%) was found between the dose to the chamber and the film, when a chamber measurement was possible The average dose difference and standard deviations between film measurements and TPS calculations were respectively 1.75% and 3%. The geometric accuracy has been estimated to be <1 mm, combining robot positioning uncertainty and film registration to calculated dose. Conclusion: Patient specific QA measurements using EBT-XD films yielded a full 2D dose plane with high spatial resolution and acceptable dose accuracy. This method is particularly promising for trigeminal neuralgia plan QA, where the positioning of the spatial dose distribution is equally or more important than the absolute delivered dose to achieve clinical goals.« less
Murata, Hiroshi; Araie, Makoto; Asaoka, Ryo
2014-11-20
We generated a variational Bayes model to predict visual field (VF) progression in glaucoma patients. This retrospective study included VF series from 911 eyes of 547 glaucoma patients as test data, and VF series from 5049 eyes of 2858 glaucoma patients as training data. Using training data, variational Bayes linear regression (VBLR) was created to predict VF progression. The performance of VBLR was compared against ordinary least-squares linear regression (OLSLR) by predicting VFs in the test dataset. The total deviation (TD) values of test patients' 11th VFs were predicted using TD values from their second to 10th VFs (VF2-10), the root mean squared error (RMSE) associated with each approach then was calculated. Similarly, mean TD (mTD) of test patients' 11th VFs was predicted using VBLR and OLSLR, and the absolute prediction errors compared. The RMSE resulting from VBLR averaged 3.9 ± 2.1 (SD) and 4.9 ± 2.6 dB for prediction based on the second to 10th VFs (VF2-10) and the second to fourth VFs (VF2-4), respectively. The RMSE resulting from OLSLR was 4.1 ± 2.0 (VF2-10) and 19.9 ± 12.0 (VF2-4) dB. The absolute prediction error (SD) for mTD using VBLR was 1.2 ± 1.3 (VF2-10) and 1.9 ± 2.0 (VF2-4) dB, while the prediction error resulting from OLSLR was 1.2 ± 1.3 (VF2-10) and 6.2 ± 6.6 (VF2-4) dB. The VBLR more accurately predicts future VF progression in glaucoma patients compared to conventional OLSLR, especially in short VF series. © ARVO.
A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andreasen, Daniel, E-mail: dana@dtu.dk
Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so-called pseudo-computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch-based method could produce accurate pCTs of the brain using conventional T{sub 1}-weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co-registered MRI/CT scan pairsmore » and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch-based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter-patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water-equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T{sub 1}-weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave-one-out fashion and compared with the CT using frequently described metrics such as the voxel-wise mean absolute error (MAE{sub vox}) and the deviation in water-equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose–volume histogram (DVH) point deviations and γ-index analysis. Results: The patch-based approach had an average MAE{sub vox} of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ-index pass rate of 0.97 using a 1%/1 mm criterion. The patch-based approach showed a significantly better performance than the baseline water pCT in almost all metrics. The approximate patch search strategy was 70x faster than a brute-force search, with an average prediction time of 20.8 min. Conclusions: The authors showed that a patch-based method based on affine registrations and T{sub 1}-weighted MRI could generate accurate pCTs of the pelvis. The main source of differences between pCT and CT was positional changes of air pockets and body outline.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magnelli, A; Smith, A; Chao, S
2016-06-15
Purpose: Spinal stereotactic body radiotherapy (SBRT) involves highly conformal dose distributions and steep dose gradients due to the proximity of the spinal cord to the treatment volume. To achieve the planning goals while limiting the spinal cord dose, patients are setup using kV cone-beam CT (kV-CBCT) with 6 degree corrections. The kV-CBCT registration with the reference CT is dependent on a user selected region of interest (ROI). The objective of this work is to determine the dosimetric impact of ROI selection. Methods: Twenty patients were selected for this study. For each patient, the kV-CBCT was registered to the reference CTmore » using three ROIs including: 1) the external body, 2) a large anatomic region, and 3) a small region focused in the target volume. Following each registration, the aligned CBCTs and contours were input to the treatment planning system for dose evaluation. The minimum dose, dose to 99% and 90% of the tumor volume (D99%, D90%), dose to 0.03cc and the dose to 10% of the spinal cord subvolume (V10Gy) were compared to the planned values. Results: The average deviations in the tumor minimum dose were 2.68%±1.7%, 4.6%±4.0%, 14.82%±9.9% for small, large and the external ROIs, respectively. The average deviations in tumor D99% were 1.15%±0.7%, 3.18%±1.7%, 10.0%±6.6%, respectively. The average deviations in tumor D90% were 1.00%±0.96%, 1.14%±1.05%, 3.19%±4.77% respectively. The average deviations in the maximum dose to the spinal cord were 2.80%±2.56%, 7.58%±8.28%, 13.35%±13.14%, respectively. The average deviation in V10Gy to the spinal cord were 1.69%±0.88%, 1.98%±2.79%, 2.71%±5.63%. Conclusion: When using automated registration algorithms for CBCT-Reference alignment, a small target-focused ROI results in the least dosimetric deviation from the plan. It is recommended to focus narrowly on the target volume to keep the spinal cord dose below tolerance.« less
Large-deviation probabilities for correlated Gaussian processes and intermittent dynamical systems
NASA Astrophysics Data System (ADS)
Massah, Mozhdeh; Nicol, Matthew; Kantz, Holger
2018-05-01
In its classical version, the theory of large deviations makes quantitative statements about the probability of outliers when estimating time averages, if time series data are identically independently distributed. We study large-deviation probabilities (LDPs) for time averages in short- and long-range correlated Gaussian processes and show that long-range correlations lead to subexponential decay of LDPs. A particular deterministic intermittent map can, depending on a control parameter, also generate long-range correlated time series. We illustrate numerically, in agreement with the mathematical literature, that this type of intermittency leads to a power law decay of LDPs. The power law decay holds irrespective of whether the correlation time is finite or infinite, and hence irrespective of whether the central limit theorem applies or not.
Results of the first North American comparison of absolute gravimeters, NACAG-2010
Schmerge, David; Francis, Olvier; Henton, J.; Ingles, D.; Jones, D.; Kennedy, Jeffrey R.; Krauterbluth, K.; Liard, J.; Newell, D.; Sands, R.; Schiel, J.; Silliker, J.; van Westrum, D.
2012-01-01
The first North American Comparison of absolute gravimeters (NACAG-2010) was hosted by the National Oceanic and Atmospheric Administration at its newly renovated Table Mountain Geophysical Observatory (TMGO) north of Boulder, Colorado, in October 2010. NACAG-2010 and the renovation of TMGO are part of NGS’s GRAV-D project (Gravity for the Redefinition of the American Vertical Datum). Nine absolute gravimeters from three countries participated in the comparison. Before the comparison, the gravimeter operators agreed to a protocol describing the strategy to measure, calculate, and present the results. Nine sites were used to measure the free-fall acceleration of g. Each gravimeter measured the value of g at a subset of three of the sites, for a total set of 27 g-values for the comparison. The absolute gravimeters agree with one another with a standard deviation of 1.6 µGal (1 Gal = 1 cm s-2). The minimum and maximum offsets are -2.8 and 2.7 µGal. This is an excellent agreement and can be attributed to multiple factors, including gravimeters that were in good working order, good operators, a quiet observatory, and a short duration time for the experiment. These results can be used to standardize gravity surveys internationally.
Effect of helicity on the correlation time of large scales in turbulent flows
NASA Astrophysics Data System (ADS)
Cameron, Alexandre; Alexakis, Alexandros; Brachet, Marc-Étienne
2017-11-01
Solutions of the forced Navier-Stokes equation have been conjectured to thermalize at scales larger than the forcing scale, similar to an absolute equilibrium obtained for the spectrally truncated Euler equation. Using direct numeric simulations of Taylor-Green flows and general-periodic helical flows, we present results on the probability density function, energy spectrum, autocorrelation function, and correlation time that compare the two systems. In the case of highly helical flows, we derive an analytic expression describing the correlation time for the absolute equilibrium of helical flows that is different from the E-1 /2k-1 scaling law of weakly helical flows. This model predicts a new helicity-based scaling law for the correlation time as τ (k ) ˜H-1 /2k-1 /2 . This scaling law is verified in simulations of the truncated Euler equation. In simulations of the Navier-Stokes equations the large-scale modes of forced Taylor-Green symmetric flows (with zero total helicity and large separation of scales) follow the same properties as absolute equilibrium including a τ (k ) ˜E-1 /2k-1 scaling for the correlation time. General-periodic helical flows also show similarities between the two systems; however, the largest scales of the forced flows deviate from the absolute equilibrium solutions.
Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A
1980-12-01
1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.
40 CFR 1065.1005 - Symbols, abbreviations, acronyms, and units of measure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... least squares regression β ratio of diameters meter per meter m/m 1 β atomic oxygen to carbon ratio mole... consumption gram per kilowatt hour g/(kW·hr) g·3.6−1·106·m−2·kg·s2 F F-test statistic f frequency hertz Hz s−1... standard deviation S Sutherland constant kelvin K K SEE standard estimate of error T absolute temperature...
40 CFR 1065.1005 - Symbols, abbreviations, acronyms, and units of measure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... least squares regression β ratio of diameters meter per meter m/m 1 β atomic oxygen to carbon ratio mole... consumption gram per kilowatt hour g/(kW·hr) g·3.6−1·106·m−2·kg·s2 F F-test statistic f frequency hertz Hz s−1... standard deviation S Sutherland constant kelvin K K SEE standard estimate of error T absolute temperature...
ERIC Educational Resources Information Center
Nienhusser, H. Kenny; Oshio, Toko
2017-01-01
High school students' accuracy in estimating the cost of college (AECC) was examined by utilizing a new methodological approach, the absolute-deviation-continuous construct. This study used the High School Longitudinal Study of 2009 (HSLS:09) data and examined 10,530 11th grade students in order to measure their AECC for 4-year public and private…
Patient-specific cardiac phantom for clinical training and preprocedure surgical planning.
Laing, Justin; Moore, John; Vassallo, Reid; Bainbridge, Daniel; Drangova, Maria; Peters, Terry
2018-04-01
Minimally invasive mitral valve repair procedures including MitraClip ® are becoming increasingly common. For cases of complex or diseased anatomy, clinicians may benefit from using a patient-specific cardiac phantom for training, surgical planning, and the validation of devices or techniques. An imaging compatible cardiac phantom was developed to simulate a MitraClip ® procedure. The phantom contained a patient-specific cardiac model manufactured using tissue mimicking materials. To evaluate accuracy, the patient-specific model was imaged using computed tomography (CT), segmented, and the resulting point cloud dataset was compared using absolute distance to the original patient data. The result, when comparing the molded model point cloud to the original dataset, resulted in a maximum Euclidean distance error of 7.7 mm, an average error of 0.98 mm, and a standard deviation of 0.91 mm. The phantom was validated using a MitraClip ® device to ensure anatomical features and tools are identifiable under image guidance. Patient-specific cardiac phantoms may allow for surgical complications to be accounted for preoperative planning. The information gained by clinicians involved in planning and performing the procedure should lead to shorter procedural times and better outcomes for patients.
[Rare earth elements contents and distribution characteristics in nasopharyngeal carcinoma tissue].
Zhang, Xiangmin; Lan, Xiaolin; Zhang, Lingzhen; Xiao, Fufu; Zhong, Zhaoming; Ye, Guilin; Li, Zong; Li, Shaojin
2016-03-01
To investigate the rare earth elements(REEs) contents and distribution characteristics in nasopharyngeal carcinoma( NPC) tissue in Gannan region. Thirty patients of NPC in Gannan region were included in this study. The REEs contents were measured by tandem mass spectrometer inductively coupled plasma(ICP-MS/MS) in 30 patients, and the REEs contents and distribution were analyzed. The average standard deviation value of REEs in lung cancer and normal lung tissues was the minimum mostly. Light REEs content was higher than the medium REEs, and medium REEs content was higher than the heavy REEs content. REEs contents changes in nasopharyngeal carcinoma were variable obviously, the absolute value of Nd, Ce, Pr, Gd and other light rare earth elements were variable widely. The degree of changes on Yb, Tb, Ho and other heavy rare earth elements were variable widely, and there was presence of Eu, Ce negative anomaly(δEu=0. 385 5, δCe= 0. 523 4). The distribution characteristic of REEs contents in NPC patients is consistent with the parity distribution. With increasing atomic sequence, the content is decline wavy. Their distribution patterns were a lack of heavy REEs and enrichment of light REEs, and there was Eu , Ce negative anomaly.
The X-ray reflectivity of the AXAF VETA-I optics
NASA Technical Reports Server (NTRS)
Kellogg, E.; Chartas, G.; Graessle, D.; Hughes, J. P.; Van Speybroeck, L.; Zhao, Ping; Weisskopf, M. C.; Elsner, R. F.; O'Dell, S. L.
1993-01-01
The study measures the X-ray reflectivity of the AXAF VETA-I optic and compares it with theoretical predictions. Measurements made at energies of 0.28, 0.9, 1.5, 2.1, and 2.3 keV are compared with predictions based on ray trace calculations. Results on the variation of the reflectivity with energy as well as the absolute value of the reflectivity are presented. A synchrotron reflectivity measurement with a high-energy resolution over the range 0.26 to 1.8 keV on a flat Zerodur sample is also reported. Evidence is found for contamination of the flat by a thin layer of carbon on the surface, and the possibility of alteration of the surface composition of the VETA-I mirror, perhaps by the polishing technique. The overall agreement between the measured and calculated effective area of VETA-I is between 2.6 and 10 percent. Measurements at individual energies deviate from the best-fitting calculation to 0.3 to 0.8 percent, averaging 0.6 percent at energies below the high energy cutoff of the mirror reflectivity, and are as high as 20.7 percent at the cutoff.
A digital system for surface reconstruction
Zhou, Weiyang; Brock, Robert H.; Hopkins, Paul F.
1996-01-01
A digital photogrammetric system, STEREO, was developed to determine three dimensional coordinates of points of interest (POIs) defined with a grid on a textureless and smooth-surfaced specimen. Two CCD cameras were set up with unknown orientation and recorded digital images of a reference model and a specimen. Points on the model were selected as control or check points for calibrating or assessing the system. A new algorithm for edge-detection called local maximum convolution (LMC) helped extract the POIs from the stereo image pairs. The system then matched the extracted POIs and used a least squares “bundle” adjustment procedure to solve for the camera orientation parameters and the coordinates of the POIs. An experiment with STEREO found that the standard deviation of the residuals at the check points was approximately 24%, 49% and 56% of the pixel size in the X, Y and Z directions, respectively. The average of the absolute values of the residuals at the check points was approximately 19%, 36% and 49% of the pixel size in the X, Y and Z directions, respectively. With the graphical user interface, STEREO demonstrated a high degree of automation and its operation does not require special knowledge of photogrammetry, computers or image processing.
NASA Astrophysics Data System (ADS)
Ansari, Ziaul Haque; Zeng, Yan; Zhang, Yan; Demopoulos, George P.; Li, Zhibao
2017-06-01
The solubility of glycine in HCl and HCl-MgCl2 solutions was measured from 283.15 to 343.15 K and found to increase with temperature and increase linearly with the concentration of HCl. The MSE model integrated in the OLI platform was modified by regressing the experimental and literature solubility data through the adjustment of the middle-range interaction parameters. After parameterization, the model can accurately calculate the solubility with the average absolute deviation lower than 3.5% and thus be able to predict supersaturation of glycine. Crystallization of different polymorphs of glycine in water, HCl, NaOH, MgCl2, and HCl-MgCl2 aqueous solutions was performed. The effects of medium, temperature, supersaturation, and time on the crystallization were investigated. It was found that only in the HCl solution the formation of single α-glycine phase was achieved under all the investigated temperature and holding time. α-glycine or its mixture with γ-glycine or C4H18N2O4·HCl was produced in systems other than HCl solution depending on the conditions.
Music playing and memory trace: evidence from event-related potentials.
Kamiyama, Keiko; Katahira, Kentaro; Abla, Dilshat; Hori, Koji; Okanoya, Kazuo
2010-08-01
We examined the relationship between motor practice and auditory memory for sound sequences to evaluate the hypothesis that practice involving physical performance might enhance auditory memory. Participants learned two unfamiliar sound sequences using different training methods. Under the key-press condition, they learned a melody while pressing a key during auditory input. Under the no-key-press condition, they listened to another melody without any key pressing. The two melodies were presented alternately, and all participants were trained in both methods. Participants were instructed to pay attention under both conditions. After training, they listened to the two melodies again without pressing keys, and ERPs were recorded. During the ERP recordings, 10% of the tones in these melodies deviated from the originals. The grand-average ERPs showed that the amplitude of mismatch negativity (MMN) elicited by deviant stimuli was larger under the key-press condition than under the no-key-press condition. This effect appeared only in the high absolute pitch group, which included those with a pronounced ability to identify a note without external reference. This result suggests that the effect of training with key pressing was mediated by individual musical skills. Copyright 2010 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.
Solubility of caffeine from green tea in supercritical CO2: a theoretical and empirical approach.
Gadkari, Pravin Vasantrao; Balaraman, Manohar
2015-12-01
Decaffeination of fresh green tea was carried out with supercritical CO2 in the presence of ethanol as co-solvent. The solubility of caffeine in supercritical CO2 varied from 44.19 × 10(-6) to 149.55 × 10(-6) (mole fraction) over a pressure and temperature range of 15 to 35 MPa and 313 to 333 K, respectively. The maximum solubility of caffeine was obtained at 25 MPa and 323 K. Experimental solubility data were correlated with the theoretical equation of state models Peng-Robinson (PR), Soave Redlich-Kwong (SRK), and Redlich-Kwong (RK). The RK model had regressed experimental data with 15.52 % average absolute relative deviation (AARD). In contrast, Gordillo empirical model regressed the best to experimental data with only 0.96 % AARD. Under supercritical conditions, solubility of caffeine in tea matrix was lower than the solubility of pure caffeine. Further, solubility of caffeine in supercritical CO2 was compared with solubility of pure caffeine in conventional solvents and a maximum solubility 90 × 10(-3) mol fraction was obtained with chloroform.
Diffusion coefficients of phenylbutazone in supercritical CO2 and in ethanol.
Kong, Chang Yi; Watanabe, Kou; Funazukuri, Toshitaka
2013-03-01
The diffusion coefficients D(12) of phenylbutazone at infinite dilution in supercritical CO(2) were measured by the chromatographic impulse response (CIR) method. The measurements were carried out over the temperature range from 308.2 to 343.2 K at pressures up to 40.0 MPa. In addition, the D(12) data of phenylbutazone at infinite dilution in ethanol were also measured by the Taylor dispersion method at 298.2-333.2K and at atmospheric pressure. The D(12) value of phenylbutazone increased from 4.45×10(-10) m(2) s(-1) at 298.2 K and 0.1 MPa in ethanol to about 1.43×10(-8) m(2) s(-1) at 343.2 K and 14.0 MPa in supercritical CO(2). It was found that all diffusion data of phenylbutazone measured in this study in supercritical CO(2) and in ethanol can be satisfactorily represented by the hydrodynamic equation over a wide range of fluid viscosity from supercritical state to liquid state with average absolute relative deviation of 5.4% for 112 data points. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Mendoza-Wilson, Ana María.; Lardizabal-Gutiérrez, Daniel; Torres-Moye, Enrique; Fuentes-Cobas, Luis; Balandrán-Quintana, René R.; Camacho-Dávila, Alejandro; Quintero-Ramos, Armando; Glossman-Mitnik, Daniel
2007-12-01
The purpose of this work was to evaluate the accuracy of the CHIH(medium)-DFT model chemistry (PBEg/CBSB2 ∗∗//PBEg/CBSB4) in the determination of the optimized structure and thermochemical properties of heterocyclic systems of medium size such as flavonoids, wherefore were selected three of the most abundant flavonoids in vegetable tissues, and which posses the higher antioxidant activity: quercetin, (+)-catechin and cyanidin. As reference systems were employed three cyclic compounds: phenol, catechol and resorcinol. The thermochemical properties evaluated were enthalpy of formation, bond dissociation enthalpy (BDE) and ionization potential (IP), following the scheme of isodesmic reactions. The theoretical results were compared with experimental data generated by X-ray diffraction and calorimetric techniques realized in part by us, whereas other data were taken from the literature. The results obtained in this work reveal that the CHIH(medium)-DFT model chemistry represents an accurate computational tool to calculate structural and thermochemical properties in the studied flavonoid and reference compounds. The average absolute deviation of enthalpy of formation for reference compounds was 3.0 kcal/mol, 2.64 kcal/mol for BDE, and 2.97 kcal/mol for IP.
Zhou, Jinhui; Xue, Xiaofeng; Li, Yi; Zhang, Jinzhen; Zhao, Jing
2007-01-01
An optimized reversed-phase high-performance liquid chromatography method was developed to detect the trans-10-hydroxy-2-decenoic acid (10-HDA) content in royal jelly cream and lyophilized powder. The sample was extracted using absolute ethanol. Chromatographic separation of 10-HDA and methyl 4-hydroxybenzoate as the internal standard was performed on a Nova-pak C18 column. The average recoveries were 95.0-99.2% (n = 5) with relative standard deviation (RSD) values of 1.3-2.1% for royal jelly cream and 98.0-100.0% (n = 5) with RSD values of 1.6-3.0% for lyophilized powder, respectively. The limits of detection and quantitation were 0.5 and 1.5 mg/kg, respectively, for both royal jelly cream and lyophilized powder. The method was validated for the determination of practical royal jelly products. The concentration of 10-HDA ranged from 1.26 to 2.21% for pure royal jelly cream samples and 3.01 to 6.19% for royal jelly lyophilized powder samples. For 30 royal jelly products, the 10-HDA content varied from not detectable to 0.98%.
Establishment of a high accuracy geoid correction model and geodata edge match
NASA Astrophysics Data System (ADS)
Xi, Ruifeng
This research has developed a theoretical and practical methodology for efficiently and accurately determining sub-decimeter level regional geoids and centimeter level local geoids to meet regional surveying and local engineering requirements. This research also provides a highly accurate static DGPS network data pre-processing, post-processing and adjustment method and a procedure for a large GPS network like the state level HRAN project. The research also developed an efficient and accurate methodology to join soil coverages in GIS ARE/INFO. A total of 181 GPS stations has been pre-processed and post-processed to obtain an absolute accuracy better than 1.5cm at 95% of the stations, and at all stations having a 0.5 ppm average relative accuracy. A total of 167 GPS stations in Iowa and around Iowa have been included in the adjustment. After evaluating GEOID96 and GEOID99, a more accurate and suitable geoid model has been established in Iowa. This new Iowa regional geoid model improved the accuracy from a sub-decimeter 10˜20 centimeter to 5˜10 centimeter. The local kinematic geoid model, developed using Kalman filtering, gives results better than third order leveling accuracy requirement with 1.5 cm standard deviation.
The Liquid State and Its Electrical Properties
1988-01-01
system. At any instant, the density will deviate from its average, and the deviation of one position r will affect that at another position r’. These...and treats the affect of the sizes of the ions incompletely. The limiting law slopes and deviations from them depend strongly on the temperature and...2,2,4-trimethylpentane, pressure increases the mobility by 30-40% at room temperature, affects little change at temperatures near 60*, and decreases
The Effect of Paid Leave on Maternal Mental Health.
Mandal, Bidisha
2018-06-07
Objectives I examined the relationship between paid maternity leave and maternal mental health among women returning to work within 12 weeks of childbirth, after 12 weeks, and those returning specifically to full-time work within 12 weeks of giving birth. Methods I used data from 3850 women who worked full-time before childbirth from the Early Childhood Longitudinal Study-Birth Cohort. I utilized propensity score matching techniques to address selection bias. Mental health was measured using the Center for Epidemiologic Studies Depression (CESD) scale, with high scores indicating greater depressive symptoms. Results Returning to work after giving birth provided psychological benefits to women who used to work full-time before childbirth. The average CESD score of women who returned to work was 0.15 standard deviation (p < 0.01) lower than the average CESD score of all women who worked full-time before giving birth. Shorter leave, on the other hand, was associated with adverse effects on mental health. The average CESD score of women who returned within 12 weeks of giving birth was 0.13 standard deviation higher (p < 0.05) than the average CESD score of all women who rejoined labor market within 9 months of giving birth. However, receipt of paid leave was associated with an improved mental health outcome. Among all women who returned to work within 12 weeks of childbirth, those women who received some paid leave had a 0.17 standard deviation (p < 0.05) lower CESD score than the average CESD score. The result was stronger for women who returned to full-time work within 12 weeks of giving birth, with a 0.32 standard deviation (p < 0.01) lower CESD score than the average CESD score. Conclusions The study revealed that the negative psychological effect of early return to work after giving birth was alleviated when women received paid leave.
NASA Technical Reports Server (NTRS)
Benedict, G. F.; McArthur, Barbara E.; Napiwotzki, Ralf; Harrison, Thomas E.; Harris, Hugh C.; Nelan, Edmund; Bond, Howard E; Patterson, Richard J.; Ciardullo, Robin
2009-01-01
We present absolute parallaxes and relative proper motions for the central stars of the planetary nebulae NGC 6853 (The Dumbbell), NGC 7293 (The Helix), Abell 31, and DeHt 5. This paper details our reduction and analysis using DeHt 5 as an example. We obtain these planetary nebula nuclei (PNNi) parallaxes with astrometric data from Fine Guidance Sensors FGS 1r and FGS 3, white-light interferometers on the Hubble Space Telescope. Proper motions, spectral classifications and VJHKT2M and DDO51 photometry of the stars comprising the astrometric reference frames provide spectrophotometric estimates of reference star absolute parallaxes. Introducing these into our model as observations with error, we determine absolute parallaxes for each PNN. Weighted averaging with previous independent parallax measurements yields an average parallax precision, sigma (sub pi)/ pi = 5%. Derived distances are: d(sub NGC6853) = 405(exp +28 sub -25) pc, d(sub NGC7293) = 216(exp +14 sub -12) pc, d(sub Abell31) = 621(exp +91 sub -70) pc, and d(sub DeHt5) = 345(exp +19 sub -17) pc. These PNNi distances are all smaller than previously derived from spectroscopic analyses of the central stars. To obtain absolute magnitudes from these distances requires estimates of interstellar extinction. We average extinction measurements culled from the literature, from reddening based on PNNi intrinsic colors derived from model SEDs, and an assumption that each PNN experiences the same rate of extinction as a function of distance as do the reference stars nearest (in angular separation) to each central star. We also apply Lutz-Kelker bias corrections. The absolute magnitudes and effective temperatures permit estimates of PNNi radii through both the Stefan-Boltzmann relation and Eddington fluxes. Comparing absolute magnitudes with post-AGB models provides mass estimates. Masses cluster around 0.57 solar Mass, close to the peak of the white dwarf mass distribution. Adding a few more PNNi with well-determined distances and masses, we compare all the PNNi with cooler white dwarfs of similar mass, and confirm, as expected, that PNNi have larger radii than white dwarfs that have reached their final cooling tracks.
Pfeiffer, Karin A; Dowda, Marsha; Dishman, Rod K; Sirard, John R; Pate, Russell R
2007-12-01
To determine how factors are related to change in cardiorespiratory fitness (CRF) across time in middle school girls followed through high school. Adolescent girls (N = 274, 59% African American, baseline age = 13.6 +/- 0.6 yr) performed a submaximal fitness test (PWC170) in 8th, 9th, and 12th grades. Height, weight, sports participation, and physical activity were also measured. Moderate-to-vigorous physical activity (MVPA) and vigorous physical activity (VPA) were determined by the number of blocks reported on the 3-Day Physical Activity Recall (3DPAR). Individual differences and developmental change in CRF were assessed simultaneously by calculating individual growth curves for each participant, using growth curve modeling. Both weight-relative and absolute CRF increased from 8th to 9th grade and decreased from 9th to 12th grade. On average, girls lost 0.16 kg.m.min.kg.yr in weight-relative PWC170 scores (P < 0.01) and gained 10.3 kg.m.min.yr in absolute PWC170 scores. Girls reporting two or more blocks of MVPA or one or more blocks of VPA at baseline showed an average increase in PWC170 scores of 0.40-0.52 kg.m.min.kg.yr (weight relative) and 22-28 kg.m.min.yr (absolute) in CRF. In weight-relative models, girls with higher BMI showed lower CRF (approximately 0.37 g.m.min.kg.yr), but this was not shown in absolute models. In absolute models, white girls (approximately 40 kg.m.min.yr) and sport participants (approximately 28 kg.m.min.yr) showed an increase in CRF over time. Although there were fluctuations in PWC170 scores across time, average scores decreased during 4 yr. Physical activity was related to change in CRF over time; BMI, race, and sport participation were also important factors related to change over time in CRF (depending on expression of CRF-weight-relative vs absolute). Subsequent research should focus on explaining the complex longitudinal interactions between CRF, physical activity, race, BMI, and sports participation.
Pyregov, A V; Ovechkin, A Iu; Petrov, S V
2012-01-01
Results of prospective randomized comparative research of 2 total hemoglobin estimation methods are presented. There were laboratory tests and continuous noninvasive technique with multiwave spectrophotometry on the Masimo Rainbow SET. Research was carried out in two stages. At the 1st stage (gynecology)--67 patients were included and in second stage (obstetrics)--44 patients during and after Cesarean section. The standard deviation of noninvasive total hemoglobin estimation from absolute values (invasive) was 7.2 and 4.1%, an standard deviation in a sample--5.2 and 2.7 % in gynecologic operations and surgical delivery respectively, that confirms lack of reliable indicators differences. The method of continuous noninvasive total hemoglobin estimation with multiwave spectrophotometry on the Masimo Rainbow SET technology can be recommended for use in obstetrics and gynecology.
Intelligence May Moderate the Cognitive Profile of Patients with ASD.
Rommelse, Nanda; Langerak, Ilse; van der Meer, Jolanda; de Bruijn, Yvette; Staal, Wouter; Oerlemans, Anoek; Buitelaar, Jan
2015-01-01
The intelligence of individuals with Autism Spectrum Disorder (ASD) varies considerably. The pattern of cognitive deficits associated with ASD may differ depending on intelligence. We aimed to study the absolute and relative severity of cognitive deficits in participants with ASD in relation to IQ. A total of 274 children (M age = 12.1, 68.6% boys) participated: 30 ASD and 22 controls in the below average Intelligence Quotient (IQ) group (IQ<85), 57 ASD and 54 controls in the average IQ group (85
Intelligence May Moderate the Cognitive Profile of Patients with ASD
Rommelse, Nanda; Langerak, Ilse; van der Meer, Jolanda; de Bruijn, Yvette; Staal, Wouter; Oerlemans, Anoek; Buitelaar, Jan
2015-01-01
Background The intelligence of individuals with Autism Spectrum Disorder (ASD) varies considerably. The pattern of cognitive deficits associated with ASD may differ depending on intelligence. We aimed to study the absolute and relative severity of cognitive deficits in participants with ASD in relation to IQ. Methods A total of 274 children (M age = 12.1, 68.6% boys) participated: 30 ASD and 22 controls in the below average Intelligence Quotient (IQ) group (IQ<85), 57 ASD and 54 controls in the average IQ group (85
Fidell, Sanford; Tabachnick, Barbara; Mestre, Vincent; Fidell, Linda
2013-11-01
Assessment of aircraft noise-induced sleep disturbance is problematic for several reasons. Current assessment methods are based on sparse evidence and limited understandings; predictions of awakening prevalence rates based on indoor absolute sound exposure levels (SELs) fail to account for appreciable amounts of variance in dosage-response relationships and are not freely generalizable from airport to airport; and predicted awakening rates do not differ significantly from zero over a wide range of SELs. Even in conjunction with additional predictors, such as time of night and assumed individual differences in "sensitivity to awakening," nominally SEL-based predictions of awakening rates remain of limited utility and are easily misapplied and misinterpreted. Probabilities of awakening are more closely related to SELs scaled in units of standard deviates of local distributions of aircraft SELs, than to absolute sound levels. Self-selection of residential populations for tolerance of nighttime noise and habituation to airport noise environments offer more parsimonious and useful explanations for differences in awakening rates at disparate airports than assumed individual differences in sensitivity to awakening.
An isotope-dilution standard GC/MS/MS method for steroid hormones in water
Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.
2013-01-01
An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.
Permutation tests for goodness-of-fit testing of mathematical models to experimental data.
Fişek, M Hamit; Barlas, Zeynep
2013-03-01
This paper presents statistical procedures for improving the goodness-of-fit testing of theoretical models to data obtained from laboratory experiments. We use an experimental study in the expectation states research tradition which has been carried out in the "standardized experimental situation" associated with the program to illustrate the application of our procedures. We briefly review the expectation states research program and the fundamentals of resampling statistics as we develop our procedures in the resampling context. The first procedure we develop is a modification of the chi-square test which has been the primary statistical tool for assessing goodness of fit in the EST research program, but has problems associated with its use. We discuss these problems and suggest a procedure to overcome them. The second procedure we present, the "Average Absolute Deviation" test, is a new test and is proposed as an alternative to the chi square test, as being simpler and more informative. The third and fourth procedures are permutation versions of Jonckheere's test for ordered alternatives, and Kendall's tau(b), a rank order correlation coefficient. The fifth procedure is a new rank order goodness-of-fit test, which we call the "Deviation from Ideal Ranking" index, which we believe may be more useful than other rank order tests for assessing goodness-of-fit of models to experimental data. The application of these procedures to the sample data is illustrated in detail. We then present another laboratory study from an experimental paradigm different from the expectation states paradigm - the "network exchange" paradigm, and describe how our procedures may be applied to this data set. Copyright © 2012 Elsevier Inc. All rights reserved.
Brambilla, Donald J; Miller, Scott T; Adams, Robert J
2007-09-01
Children with sickle cell disease (SCD) are at elevated risk of stroke. Risk increases with blood flow velocity in selected cerebral arteries, as measured by transcranial Doppler (TCD) ultrasound, and use of TCD to screen these patients is widely recommended. Interpretation of TCD results should be based on knowledge of intra-individual variation in blood flow velocity, information not currently available for sickle cell patients. Between 1995 and 2002, 4,141 subjects, 2-16 years old, with homozygous SCD or Sbeta0-thalasemmia and no history of stroke were screened with TCD, including 2,018 subjects screened in one clinical trial (STOP), 1,816 screened in another (STOP 2), and 307 screened in an interim ancillary prospective study. The 812 subjects with >or=2 examinations<6 months apart were selected for analysis, including 242 (29.8%) subjects with normal average velocities (i.e., <170 cm/sec), 350 (43.1%) subjects with conditional velocities (i.e., 170-199 cm/sec), and 220 (27.1%) subjects with abnormal velocities (i.e., >or=200 cm/sec). The intra-subject standard deviation of TCD velocity was estimated from the difference between velocities at the first two interpretable examinations on each subject. An intra-subject standard deviation of 14.9 cm/sec was obtained. Seven (0.9%) subjects had unusually large and unexplained differences between velocities at the two examinations (range of absolute differences: 69-112 cm/sec). While stroke risk is well demonstrated to increase with increasingly abnormal TCD velocity, given the relatively large intra-subject variability, one TCD examination is generally not sufficient to characterize stroke risk in this patient population. Copyright (c) 2007 Wiley-Liss, Inc.
40 CFR 60.2958 - What must I include in the deviation report?
Code of Federal Regulations, 2010 CFR
2010-07-01
... limitations or operating limit requirements. (b) The averaged and recorded data for those dates. (c) Durations and causes of each deviation from the emission limitations or operating limits and your corrective... limitations or operating limits specified in this subpart, include the seven items described in paragraphs (a...
40 CFR 60.3053 - What must I include in the deviation report?
Code of Federal Regulations, 2010 CFR
2010-07-01
... limitations or operating limit requirements. (b) The averaged and recorded data for those dates. (c) Durations and causes of each deviation from the emission limitations or operating limits and your corrective... limitations or operating limits specified in this subpart, include the seven items described in paragraphs (a...
Corrective responses in human food intake identified from an analysis of 7-d food-intake records2
Bray, George A; Flatt, Jean-Pierre; Volaufova, Julia; DeLany, James P; Champagne, Catherine M
2009-01-01
Background We tested the hypothesis that ad libitum food intake shows corrective responses over periods of 1–5 d. Design This was a prospective study of food intake in women. Methods Two methods, a weighed food intake and a measured food intake, were used to determine daily nutrient intake during 2 wk in 20 women. Energy expenditure with the use of doubly labeled water was done contemporaneously with the weighed food-intake record. The daily deviations in macronutrient and energy intake from the average 7-d values were compared with the deviations observed 1, 2, 3, 4, and 5 d later to estimate the corrective responses. Results Both methods of recording food intake gave similar patterns of macronutrient and total energy intakes and for deviations from average intakes. The intraindividual CVs for energy intake ranged from ±12% to ±47% with an average of ±25%. Reported energy intake was 85.5–95.0% of total energy expenditure determined by doubly labeled water. Significant corrective responses were observed in food intakes with a 3- to 4-d lag that disappeared when data were randomized within each subject. Conclusions Human beings show corrective responses to deviations from average energy and macronutrient intakes with a lag time of 3–4 d, but not 1–2 d. This suggests that short-term studies may fail to recognize important signals of food-intake regulation that operate over several days. These corrective responses probably play a crucial role in bringing about weight stability. PMID:19064509
Photon scattering cross sections of H2 and He measured with synchrotron radiation
NASA Technical Reports Server (NTRS)
Ice, G. E.
1977-01-01
Total (elastic + inelastic) differential photon scattering cross sections have been measured for H2 gas and He, using an X-ray beam. Absolute measured cross sections agree with theory within the probable errors. Relative cross sections (normalized to theory at large S) agree to better than one percent with theoretical values calculated from wave functions that include the effect of electron-electron Coulomb correlation, but the data deviate significantly from theoretical independent-particle (e.g., Hartree-Fock) results. The ratios of measured absolute He cross sections to those of H2, at any given S, also agree to better than one percent with theoretical He-to-H2 cross-section ratios computed from correlated wave functions. It appears that photon scattering constitutes a very promising tool for probing electron correlation in light atoms and molecules.
NASA Astrophysics Data System (ADS)
Nagarajan, K.; Shashidharan Nair, C. K.
2007-07-01
The channelled spectrum employing polarized light interference is a very convenient method for the study of dispersion of birefringence. However, while using this method, the absolute order of the polarized light interference fringes cannot be determined easily. Approximate methods are therefore used to estimate the order. One of the approximations is that the dispersion of birefringence across neighbouring integer order fringes is negligible. In this paper, we show how this approximation can cause errors. A modification is reported whereby the error in the determination of absolute fringe order can be reduced using fractional orders instead of integer orders. The theoretical background for this method supported with computer simulation is presented. An experimental arrangement implementing these modifications is described. This method uses a Constant Deviation Spectrometer (CDS) and a Soleil Babinet Compensator (SBC).
NASA Astrophysics Data System (ADS)
Klaessens, John H.; van der Veen, Albert; Verdaasdonk, Rudolf M.
2017-03-01
Recently, low cost smart phone based thermal cameras are being considered to be used in a clinical setting for monitoring physiological temperature responses such as: body temperature change, local inflammations, perfusion changes or (burn) wound healing. These thermal cameras contain uncooled micro-bolometers with an internal calibration check and have a temperature resolution of 0.1 degree. For clinical applications a fast quality measurement before use is required (absolute temperature check) and quality control (stability, repeatability, absolute temperature, absolute temperature differences) should be performed regularly. Therefore, a calibrated temperature phantom has been developed based on thermistor heating on both ends of a black coated metal strip to create a controllable temperature gradient from room temperature 26 °C up to 100 °C. The absolute temperatures on the strip are determined with software controlled 5 PT-1000 sensors using lookup tables. In this study 3 FLIR-ONE cameras and one high end camera were checked with this temperature phantom. The results show a relative good agreement between both low-cost and high-end camera's and the phantom temperature gradient, with temperature differences of 1 degree up to 6 degrees between the camera's and the phantom. The measurements were repeated as to absolute temperature and temperature stability over the sensor area. Both low-cost and high-end thermal cameras measured relative temperature changes with high accuracy and absolute temperatures with constant deviations. Low-cost smart phone based thermal cameras can be a good alternative to high-end thermal cameras for routine clinical measurements, appropriate to the research question, providing regular calibration checks for quality control.
Mehta, Amar J.; Kloog, Itai; Zanobetti, Antonella; Coull, Brent A.; Sparrow, David; Vokonas, Pantel; Schwartz, Joel
2014-01-01
Background The underlying mechanisms of the association between ambient temperature and cardiovascular morbidity and mortality are not well understood, particularly for daily temperature variability. We evaluated if daily mean temperature and standard deviation of temperature was associated with heart rate-corrected QT interval (QTc) duration, a marker of ventricular repolarization in a prospective cohort of older men. Methods This longitudinal analysis included 487 older men participating in the VA Normative Aging Study with up to three visits between 2000–2008 (n = 743). We analyzed associations between QTc and moving averages (1–7, 14, 21, and 28 days) of the 24-hour mean and standard deviation of temperature as measured from a local weather monitor, and the 24-hour mean temperature estimated from a spatiotemporal prediction model, in time-varying linear mixed-effect regression. Effect modification by season, diabetes, coronary heart disease, obesity, and age was also evaluated. Results Higher mean temperature as measured from the local monitor, and estimated from the prediction model, was associated with longer QTc at moving averages of 21 and 28 days. Increased 24-hr standard deviation of temperature was associated with longer QTc at moving averages from 4 and up to 28 days; a 1.9°C interquartile range increase in 4-day moving average standard deviation of temperature was associated with a 2.8 msec (95%CI: 0.4, 5.2) longer QTc. Associations between 24-hr standard deviation of temperature and QTc were stronger in colder months, and in participants with diabetes and coronary heart disease. Conclusion/Significance In this sample of older men, elevated mean temperature was associated with longer QTc, and increased variability of temperature was associated with longer QTc, particularly during colder months and among individuals with diabetes and coronary heart disease. These findings may offer insight of an important underlying mechanism of temperature-related cardiovascular morbidity and mortality in an older population. PMID:25238150
Optical frequency transfer via a 660 km underground fiber link using a remote Brillouin amplifier.
Raupach, S M F; Koczwara, A; Grosche, G
2014-11-03
In long-distance, optical continuous-wave frequency transfer via fiber, remote bidirectional Er³ ⁺ -doped fiber amplifiers are commonly used to mitigate signal attenuation. We demonstrate for the first time the ultrastable transfer of an optical frequency using a remote fiber Brillouin amplifier, placed in a server room along the link. Using it as the only means of remote amplification, on a 660 km loop of installed underground fiber we bridge distances of 250 km and 160 km between amplifications. Over several days of uninterrupted measurement, we find an instability of the frequency transfer (Allan deviation of Λ-weighted data with 1 s gate time) of around 1 × 10(-19) and less for averaging times longer than 3000 s. The modified Allan deviation reaches 3 × 10(-19) at an averaging time of 100 s. Beyond 100 s it follows the interferometer noise floor, and for averaging times longer than 1000 s the modified Allan deviation is in the 10(-20) range. A conservative value of the overall accuracy is 1 × 10(-19)
Absolute dual-comb spectroscopy at 1.55 μm by free-running Er:fiber lasers
NASA Astrophysics Data System (ADS)
Cassinerio, Marco; Gambetta, Alessio; Coluccelli, Nicola; Laporta, Paolo; Galzerano, Gianluca
2014-06-01
We report on a compact scheme for absolute referencing and coherent averaging for dual-comb based spectrometers, exploiting a single continuous-wave (CW) laser in a transfer oscillator configuration. The same CW laser is used for both absolute calibration of the optical frequency axis and the generation of a correction signal which is used for a real-time jitter compensation in a fully electrical feed-forward scheme. The technique is applied to a near-infrared spectrometer based on a pair of free-running mode-locked Er:fiber lasers, allowing to perform real-time absolute-frequency measurements over an optical bandwidth of more than 25 nm, with coherent interferogram averaging over 1-s acquisition time, leading to a signal-to-noise ratio improvement of 29 dB over the 50 μs single shot acquisition. Using 10-cm single pass cell, a value of 1.9 × 10-4 cm-1 Hz-0.5 noise-equivalent-absorption over 1 s integration time is obtained, which can be further scaled down with a multi-pass or resonant cavity. The adoption of a single CW laser, together with the absence of optical locks, and the full-fiber design makes this spectrometer a robust and compact system to be employed in gas-sensing applications.
The statistical properties and possible causes of polar motion prediction errors
NASA Astrophysics Data System (ADS)
Kosek, Wieslaw; Kalarus, Maciej; Wnek, Agnieszka; Zbylut-Gorska, Maria
2015-08-01
The pole coordinate data predictions from different prediction contributors of the Earth Orientation Parameters Combination of Prediction Pilot Project (EOPCPPP) were studied to determine the statistical properties of polar motion forecasts by looking at the time series of differences between them and the future IERS pole coordinates data. The mean absolute errors, standard deviations as well as the skewness and kurtosis of these differences were computed together with their error bars as a function of prediction length. The ensemble predictions show a little smaller mean absolute errors or standard deviations however their skewness and kurtosis values are similar as the for predictions from different contributors. The skewness and kurtosis enable to check whether these prediction differences satisfy normal distribution. The kurtosis values diminish with the prediction length which means that the probability distribution of these prediction differences is becoming more platykurtic than letptokurtic. Non zero skewness values result from oscillating character of these differences for particular prediction lengths which can be due to the irregular change of the annual oscillation phase in the joint fluid (atmospheric + ocean + land hydrology) excitation functions. The variations of the annual oscillation phase computed by the combination of the Fourier transform band pass filter and the Hilbert transform from pole coordinates data as well as from pole coordinates model data obtained from fluid excitations are in a good agreement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Sunghwan; Hong, Kwangwoo; Kim, Jaewook
2015-03-07
We developed a self-consistent field program based on Kohn-Sham density functional theory using Lagrange-sinc functions as a basis set and examined its numerical accuracy for atoms and molecules through comparison with the results of Gaussian basis sets. The result of the Kohn-Sham inversion formula from the Lagrange-sinc basis set manifests that the pseudopotential method is essential for cost-effective calculations. The Lagrange-sinc basis set shows faster convergence of the kinetic and correlation energies of benzene as its size increases than the finite difference method does, though both share the same uniform grid. Using a scaling factor smaller than or equal tomore » 0.226 bohr and pseudopotentials with nonlinear core correction, its accuracy for the atomization energies of the G2-1 set is comparable to all-electron complete basis set limits (mean absolute deviation ≤1 kcal/mol). The same basis set also shows small mean absolute deviations in the ionization energies, electron affinities, and static polarizabilities of atoms in the G2-1 set. In particular, the Lagrange-sinc basis set shows high accuracy with rapid convergence in describing density or orbital changes by an external electric field. Moreover, the Lagrange-sinc basis set can readily improve its accuracy toward a complete basis set limit by simply decreasing the scaling factor regardless of systems.« less
NASA Astrophysics Data System (ADS)
Armstrong, Hannah; Boese, Matthew; Carmichael, Cody; Dimich, Hannah; Seay, Dylan; Sheppard, Nathan; Beekman, Matt
2017-01-01
Maximum thermoelectric energy conversion efficiencies are calculated using the conventional "constant property" model and the recently proposed "cumulative/average property" model (Kim et al. in Proc Natl Acad Sci USA 112:8205, 2015) for 18 high-performance thermoelectric materials. We find that the constant property model generally predicts higher energy conversion efficiency for nearly all materials and temperature differences studied. Although significant deviations are observed in some cases, on average the constant property model predicts an efficiency that is a factor of 1.16 larger than that predicted by the average property model, with even lower deviations for temperature differences typical of energy harvesting applications. Based on our analysis, we conclude that the conventional dimensionless figure of merit ZT obtained from the constant property model, while not applicable for some materials with strongly temperature-dependent thermoelectric properties, remains a simple yet useful metric for initial evaluation and/or comparison of thermoelectric materials, provided the ZT at the average temperature of projected operation, not the peak ZT, is used.
NASA Astrophysics Data System (ADS)
Huang, Dong; Campos, Edwin; Liu, Yangang
2014-09-01
Statistical characteristics of cloud variability are examined for their dependence on averaging scales and best representation of probability density function with the decade-long retrieval products of cloud liquid water path (LWP) from the tropical western Pacific (TWP), Southern Great Plains (SGP), and North Slope of Alaska (NSA) sites of the Department of Energy's Atmospheric Radiation Measurement Program. The statistical moments of LWP show some seasonal variation at the SGP and NSA sites but not much at the TWP site. It is found that the standard deviation, relative dispersion (the ratio of the standard deviation to the mean), and skewness all quickly increase with the averaging window size when the window size is small and become more or less flat when the window size exceeds 12 h. On average, the cloud LWP at the TWP site has the largest values of standard deviation, relative dispersion, and skewness, whereas the NSA site exhibits the least. Correlation analysis shows that there is a positive correlation between the mean LWP and the standard deviation. The skewness is found to be closely related to the relative dispersion with a correlation coefficient of 0.6. The comparison further shows that the lognormal, Weibull, and gamma distributions reasonably explain the observed relationship between skewness and relative dispersion over a wide range of scales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Dong; Campos, Edwin; Liu, Yangang
2014-09-17
Statistical characteristics of cloud variability are examined for their dependence on averaging scales and best representation of probability density function with the decade-long retrieval products of cloud liquid water path (LWP) from the tropical western Pacific (TWP), Southern Great Plains (SGP), and North Slope of Alaska (NSA) sites of the Department of Energy’s Atmospheric Radiation Measurement Program. The statistical moments of LWP show some seasonal variation at the SGP and NSA sites but not much at the TWP site. It is found that the standard deviation, relative dispersion (the ratio of the standard deviation to the mean), and skewness allmore » quickly increase with the averaging window size when the window size is small and become more or less flat when the window size exceeds 12 h. On average, the cloud LWP at the TWP site has the largest values of standard deviation, relative dispersion, and skewness, whereas the NSA site exhibits the least. Correlation analysis shows that there is a positive correlation between the mean LWP and the standard deviation. The skewness is found to be closely related to the relative dispersion with a correlation coefficient of 0.6. The comparison further shows that the log normal, Weibull, and gamma distributions reasonably explain the observed relationship between skewness and relative dispersion over a wide range of scales.« less
Esophageal motion during radiotherapy: quantification and margin implications.
Cohen, R J; Paskalev, K; Litwin, S; Price, R A; Feigenberg, S J; Konski, A A
2010-08-01
The purpose was to evaluate interfraction and intrafraction esophageal motion in the right-left (RL) and anterior-posterior (AP) directions using computed tomography (CT) in esophageal cancer patients. Eight patients underwent CT simulation and CT-on-rails imaging before and after radiotherapy. Interfraction displacement was defined as differences between pretreatment and simulation images. Intrafraction displacement was defined as differences between pretreatment and posttreatment images. Images were fused using bone registries, adjusted to the carina. The mean, average of the absolute, and range of esophageal motion were calculated in the RL and AP directions, above and below the carina. Thirty-one CT image sets were obtained. The incidence of esophageal interfraction motion > or =5 mm was 24% and > or =10 mm was 3%; intrafraction motion > or =5 mm was 13% and > or =10 mm was 4%. The average RL motion was 1.8 +/- 5.1 mm, favoring leftward movement, and the average AP motion was 0.6 +/- 4.8 mm, favoring posterior movement. Average absolute motion was 4.2 mm or less in the RL and AP directions. Motion was greatest in the RL direction above the carina. Coverage of 95% of esophageal mobility requires 12 mm left, 8 mm right, 10 mm posterior, and 9 mm anterior margins. In all directions, the average of the absolute interfraction and intrafraction displacement was 4.2 mm or less. These results support a 12 mm left, 8 mm right, 10 mm posterior, and 9 mm anterior margin for internal target volume (ITV) and can guide margins for future intensity modulated radiation therapy (IMRT) trials to account for organ motion and set up error in three-dimensional planning.
Global Summary MGS TES Data and Mars-Gram Validation
NASA Technical Reports Server (NTRS)
Justus, C.; Johnson, D.; Parker, Nelson C. (Technical Monitor)
2002-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many Mars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model (MGCM), while above 80 km it is based on University of Arizona Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topograph$ from Mars Global Surveyor Mars Orbiting Laser Altimeter (MOLA). Validation studies are described comparing Mars-GRAM with a global summary data set of Mars Global Surveyor Thermal Emission Spectrometer (TES) data. TES averages and standard deviations were assembled from binned TES data which covered surface to approx. 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of a Mars global dust storm). TES data were binned in 10-by-10 degree latitude-longitude bins (i.e. 36 longitude bins by 19 latitude bins), 12 seasonal bins (based on 30 degree increments of Ls angle). Bin averages and standard deviations were assembled at 23 data levels (temperature at 21 pressure levels, plus surface temperature and surface pressure). Two time-of day bins were used: local time near 2 or 14 hours local time). Two dust optical depth bins wereused: infrared optical depth either less than or greater than 0.25 (which corresponds to visible optical depth either less than or greater than about 0.5). For interests in aerocapture and precision entry and landing, comparisons focused on atmospheric density. TES densities versus height were computed from TES temperature versus pressure, using assumptions of perfect gas law and hydrostatics. Mars-GRAM validation studies used density ratio (TES/Mars-GRAM) evaluated at data bin center points in space and time. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (> 45 deg N), or at most altitudes in the southern hemisphere at Ls approx. 90 and 180deg). Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approx. 65-10.5% (varying with height) for all data, or approx. 5-12%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for local time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about the same as the standard deviation of TES data about the TES mean value at a given position and season.
Visual field progression in glaucoma: total versus pattern deviation analyses.
Artes, Paul H; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C
2005-12-01
To compare visual field progression with total and pattern deviation analyses in a prospective longitudinal study of patients with glaucoma and healthy control subjects. A group of 101 patients with glaucoma (168 eyes) with early to moderately advanced visual field loss at baseline (average mean deviation [MD], -3.9 dB) and no clinical evidence of media opacity were selected from a prospective longitudinal study on visual field progression in glaucoma. Patients were examined with static automated perimetry at 6-month intervals for a median follow-up of 9 years. At each test location, change was established with event and trend analyses of total and pattern deviation. The event analyses compared each follow-up test to a baseline obtained from averaging the first two tests, and visual field progression was defined as deterioration beyond the 5th percentile of test-retest variability at three test locations, observed on three consecutive tests. The trend analyses were based on point-wise linear regression, and visual field progression was defined as statistically significant deterioration (P < 5%) worse than -1 dB/year at three locations, confirmed by independently omitting the last and the penultimate observation. The incidence and the time-to-progression were compared between total and pattern deviation analyses. To estimate the specificity of the progression analyses, identical criteria were applied to visual fields obtained in 102 healthy control subjects, and the rate of visual field improvement was established in the patients with glaucoma and the healthy control subjects. With both event and trend methods, pattern deviation analyses classified approximately 15% fewer eyes as having progressed than did the total deviation analyses. In eyes classified as progressing by both the total and pattern deviation methods, total deviation analyses tended to detect progression earlier than the pattern deviation analyses. A comparison of the changes observed in MD and the visual fields' general height (estimated by the 85th percentile of the total deviation values) confirmed that change in the glaucomatous eyes almost always comprised a diffuse component. Pattern deviation analyses of progression may therefore underestimate the true amount of glaucomatous visual field progression. Pattern deviation analyses of visual field progression may underestimate visual field progression in glaucoma, particularly when there is no clinical evidence of increasing media opacity. Clinicians should have access to both total and pattern deviation analyses to make informed decisions on visual field progression in glaucoma.
MOSFET detectors in quality assurance of tomotherapy treatments.
Cherpak, Amanda; Studinski, Ryan C N; Cygler, Joanna E
2008-02-01
The purpose of this work was to characterize metal oxide semiconductor field-effect transistors (MOSFETs) in a 6 MV conventional linac and investigate their use for quality assurance of radiotherapy treatments with a tomotherapy Hi-Art unit. High sensitivity and standard sensitivity MOSFETs were first calibrated and then tested for reproducibility, field size dependence, and accuracy of measuring surface dose in a 6 MV beam as well as in a tomotherapy Hi-Art unit. In vivo measurements were performed on both a RANDO phantom and several head and neck cancer patients treated with tomotherapy and compared to TLD measurements and treatment plan doses to evaluate the performance of MOSFETs in a high gradient radiation field. The average calibration factor found was 0.345+/-2.5%cGy/mV for the high sensitivity MOSFETs tested and 0.901+/-2.4%cGy/mV for the standard sensitivity MOSFETs. MOSFET measured surface doses had an average agreement with ion chamber measurements of 1.55% for the high sensitivity MOSFET and 5.23% for the standard sensitivity MOSFET when averaged over all trials and field sizes tested. No significant dependence on field size was found for the standard sensitivity MOSFETs, however a maximum difference of 5.34% was found for the high sensitivity MOSFET calibration factors in the field sizes tested. Measurements made with MOSFETS on head and neck patients treated on a tomotherapy Hi-Art unit had an average agreement of (3.26+/-0.03)% with TLD measurements, however the average of the absolute difference between the MOSFET measurements and the treatment plan skin doses was (12.2+/-7.5)%. The MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1.4% to 6.6%. Similar results were found from trials using a RANDO phantom. The MOSFETs performed well when used in the tomotherapy Hi-Art unit and did not increase the overall treatment set-up time when used for patient measurements. It was found that MOSFETs are suitable detectors for surface dose measurements in both conventional beam and tomotherapy treatments and they can provide valuable skin dose information in areas where the treatment planning system may not be accurate.
Calibration Against the Moon. I: A Disk-Resolved Lunar Model for Absolute Reflectance Calibration
2010-01-01
average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and...3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Calibration against the Moon I: A disk- resolved lunar model for absolute reflectance...of the disk- resolved Moon at visible to near infrared wavelengths. It has been developed in order to use the Moon as a calibration reference
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, D; Koch, N; Peng, J
2015-06-15
Purpose: To examine the feasibility of using Varian’s EPID-based Machine Performance Check (MPC) system to track daily machine output through comparison with Sun Nuclear’s DailyQA3 (DQA) device. Methods: Daily machine outputs for two photon energies (6 and 16MV) and five electron energies (6, 9, 12, 16, 20MeV) were measured for one month using both MPC and DQA. Baselines measurements for MPC were taken at the start of the measurement series, while DQA baselines were set at an earlier date. In order to make absolute comparisons with MPC, all DQA readings were referenced to the average of the first three DQAmore » readings in that series, minimizing systematic differences between the measurement techniques due to baseline differences. In addition to daily output measurements, weekly averages were also calculated and compared. Finally, the electron energy dependence of each measurement technique was examined by comparing energy-specific measurements to the average electron output of all energies each day. Results: For 6 and 16MV photons, the largest absolute percent differences between MPC and DQA were 0.60% and 0.73%, respectively. Weekly averages were within 0.17% and 0.23%, respectively. For all five electron energies, the greatest absolute percent differences between MPC and DQA for each energy ranged from 0.49%–0.83%. Weekly averages ranged from 0.07%–0.28%. DQA energy-specific electron readings matched the average electron output within 0.29% for all days and all energies. MPC energy-specific readings matched the average within 0.21% for 9–20MeV. However, 6MeV showed a larger distribution about the average with four days showing a difference greater than 0.30% and a maximum difference of 0.51%. Conclusion: MPC output measurements correlated well with the widely-used DQA3 for most beam energies, making it a reliable back up technique for daily output monitoring. However, MPC may display an energy dependence for lower electrons energies, requiring additional investigation.« less
Age-specific absolute and relative organ weight distributions for B6C3F1 mice.
Marino, Dale J
2012-01-01
The B6C3F1 mouse is the standard mouse strain used in toxicology studies conducted by the National Cancer Institute (NCI) and the National Toxicology Program (NTP). While numerous reports have been published on growth, survival, and tumor incidence, no overall compilation of organ weight data is available. Importantly, organ weight change is an endpoint used by regulatory agencies to develop toxicity reference values (TRVs) for use in human health risk assessments. Furthermore, physiologically based pharmacokinetic (PBPK) models, which utilize relative organ weights, are increasingly being used to develop TRVs. Therefore, all available absolute and relative organ weight data for untreated control B6C3F1 mice were collected from NCI/NTP studies in order to develop age-specific distributions. Results show that organ weights were collected more frequently in NCI/NTP studies at 2-wk (60 studies), 3-mo (147 studies), and 15-mo (40 studies) intervals than at other intervals, and more frequently from feeding and inhalation than drinking water studies. Liver, right kidney, lung, heart, thymus, and brain weights were most frequently collected. From the collected data, the mean and standard deviation for absolute and relative organ weights were calculated. Results show age-related increases in absolute liver, right kidney, lung, and heart weights and relatively stable brain and right testis weights. The results suggest a general variability trend in absolute organ weights of brain < right testis < right kidney < heart < liver < lung < spleen < thymus. This report describes the results of this effort.
NASA Technical Reports Server (NTRS)
Mehdipour, M.; Kaastra, J. S.; Kallman, T.
2016-01-01
Atomic data and plasma models play a crucial role in the diagnosis and interpretation of astrophysical spectra, thus influencing our understanding of the Universe. In this investigation we present a systematic comparison of the leading photoionization codes to determine how much their intrinsic differences impact X-ray spectroscopic studies of hot plasmas in photoionization equilibrium. We carry out our computations using the Cloudy, SPEX, and XSTAR photoionization codes, and compare their derived thermal and ionization states for various ionizing spectral energy distributions. We examine the resulting absorption-line spectra from these codes for the case of ionized outflows in active galactic nuclei. By comparing the ionic abundances as a function of ionization parameter, we find that on average there is about 30 deviation between the codes in where ionic abundances peak. For H-like to B-like sequence ions alone, this deviation in is smaller at about 10 on average. The comparison of the absorption-line spectra in the X-ray band shows that there is on average about 30 deviation between the codes in the optical depth of the lines produced at log 1 to 2, reducing to about 20 deviation at log 3. We also simulate spectra of the ionized outflows with the current and upcoming high-resolution X-ray spectrometers, on board XMM-Newton, Chandra, Hitomi, and Athena. From these simulations we obtain the deviation on the best-fit model parameters, arising from the use of different photoionization codes, which is about 10 to40. We compare the modeling uncertainties with the observational uncertainties from the simulations. The results highlight the importance of continuous development and enhancement of photoionization codes for the upcoming era of X-ray astronomy with Athena.
The trading time risks of stock investment in stock price drop
NASA Astrophysics Data System (ADS)
Li, Jiang-Cheng; Tang, Nian-Sheng; Mei, Dong-Cheng; Li, Yun-Xian; Zhang, Wan
2016-11-01
This article investigates the trading time risk (TTR) of stock investment in the case of stock price drop of Dow Jones Industrial Average (ˆDJI) and Hushen300 data (CSI300), respectively. The escape time of stock price from the maximum to minimum in a data window length (DWL) is employed to measure the absolute TTR, the ratio of the escape time to data window length is defined as the relative TTR. Empirical probability density functions of the absolute and relative TTRs for the ˆDJI and CSI300 data evidence that (i) whenever the DWL increases, the absolute TTR increases, the relative TTR decreases otherwise; (ii) there is the monotonicity (or non-monotonicity) for the stability of the absolute (or relative) TTR; (iii) there is a peak distribution for shorter trading days and a two-peak distribution for longer trading days for the PDF of ratio; (iv) the trading days play an opposite role on the absolute (or relative) TTR and its stability between ˆDJI and CSI300 data.
Ganglion cell complex scan in the early prediction of glaucoma.
Ganekal, S
2012-01-01
To compare the macular ganglion cell complex (GCC) with peripapillary retinal fiber layer (RNFL) thickness map in glaucoma suspects and patients. Forty participants (20 glaucoma suspects and 20 glaucoma patients) were enrolled. Macular GCC and RNFL thickness maps were performed in both eyes of each participant in the same visit. The sensitivity and specificity of a color code less than 5% (red or yellow) for glaucoma diagnosis were calculated. Standard Automated Perimetry was performed with the Octopus 3.1.1 Dynamic 24-2 program. The statistical analysis was performed with the SPSS 10.1 (SPSS Inc. Chicago, IL, EUA). Results were expressed as mean +/- standard deviation and a p value of 0.05 or less was considered significant. Provide absolute numbers of these findings with their units of measurement. There was a statistically significant difference in average RNFL thickness (p=0.004), superior RNFL thickness (p=0.006), inferior RNFL thickness (p=0.0005) and average GCC (p=0.03) between the suspects and glaucoma patients. There was no difference in optic disc area (p=0.35) and vertical cup/disc ratio (p=0.234) in both groups. While 38% eyes had an abnormal GCC and 13% had an abnormal RNFL thickness in the glaucoma suspect group, 98% had an abnormal GCC and 90% had an abnormal RNFL thickness in the glaucoma group. The ability to diagnose glaucoma with macular GCC thickness is comparable to that with peripapillary RNFL thickness . Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma. © NEPjOPH.
Determination of split renal function using dynamic CT-angiography: preliminary results.
Helck, Andreas; Schönermarck, Ulf; Habicht, Antje; Notohamiprodjo, Mike; Stangl, Manfred; Klotz, Ernst; Nikolaou, Konstantin; la Fougère, Christian; Clevert, Dirk Andrè; Reiser, Maximilian; Becker, Christoph
2014-01-01
To determine the feasibility of a dynamic CT angiography-protocol with regard to simultaneous assessment of renal anatomy and function. 7 healthy potential kidney donors (58 ± 7 years) underwent a dynamic computed tomography angiography (CTA) using a 128-slice CT-scanner with continuous bi-directional table movement, allowing the coverage of a scan range of 18 cm within 1.75 sec. Twelve scans of the kidneys (n = 14) were acquired every 3.5 seconds with the aim to simultaneously obtain CTA and renal function data. Image quality was assessed quantitatively (HU-measurements) and qualitatively (grade 1-4, 1 = best). The glomerular filtration rate (GFR) was calculated by a modified Patlak method and compared with the split renal function obtained with renal scintigraphy. Mean maximum attenuation was 464 ± 58 HU, 435 ± 48 HU and 277 ± 29 HU in the aorta, renal arteries, and renal veins, respectively. The abdominal aorta and all renal vessels were depicted excellently (grade 1.0). The image quality score for cortex differentiation was 1.6 ± 0.49, for the renal parenchyma 2.4 ± 0.49. GFR obtained from dynamic CTA correlated well with renal scintigraphy with a correlation coefficient of r = 0.84; P = 0.0002 (n = 14). The average absolute deviation was 1.6 mL/min. The average effective dose was 8.96 mSv. Comprehensive assessment of renal anatomy and function is feasible using a single dynamic CT angiography examination. The proposed protocol may help to improve management in case of asymmetric kidney function as well as to simplify evaluation of potential living kidney donors.
NASA Astrophysics Data System (ADS)
Li, Yongming; Li, Fan; Wang, Pin; Zhu, Xueru; Liu, Shujun; Qiu, Mingguo; Zhang, Jingna; Zeng, Xiaoping
2016-10-01
Traditional age estimation methods are based on the same idea that uses the real age as the training label. However, these methods ignore that there is a deviation between the real age and the brain age due to accelerated brain aging. This paper considers this deviation and searches for it by maximizing the separability distance value rather than by minimizing the difference between the estimated brain age and the real age. Firstly, set the search range of the deviation as the deviation candidates according to prior knowledge. Secondly, use the support vector regression (SVR) as the age estimation model to minimize the difference between the estimated age and the real age plus deviation rather than the real age itself. Thirdly, design the fitness function based on the separability distance criterion. Fourthly, conduct age estimation on the validation dataset using the trained age estimation model, put the estimated age into the fitness function, and obtain the fitness value of the deviation candidate. Fifthly, repeat the iteration until all the deviation candidates are involved and get the optimal deviation with maximum fitness values. The real age plus the optimal deviation is taken as the brain pathological age. The experimental results showed that the separability was apparently improved. For normal control-Alzheimer’s disease (NC-AD), normal control-mild cognition impairment (NC-MCI), and MCI-AD, the average improvements were 0.178 (35.11%), 0.033 (14.47%), and 0.017 (39.53%), respectively. For NC-MCI-AD, the average improvement was 0.2287 (64.22%). The estimated brain pathological age could be not only more helpful to the classification of AD but also more precisely reflect accelerated brain aging. In conclusion, this paper offers a new method for brain age estimation that can distinguish different states of AD and can better reflect the extent of accelerated aging.
Solid-gas phase equilibria and thermodynamic properties of cadmium selenide.
NASA Technical Reports Server (NTRS)
Sigai, A. G.; Wiedemeier, H.
1972-01-01
Accurate vapor pressures are determined through direct weight loss measurements using the Knudsen effusion technique. The experimental data are evaluated by establishing the mode of vaporization and determining the heat capacity of cadmium selenide at elevated temperatures. Additional information is obtained through a second- and third-law evaluation of data, namely, the heat of formation and the absolute entropy of cadmium selenide. A preferential loss of selenium during the initial heating of CdSe is observed, which leads to a deviation in stoichiometry.
Robust Programming Problems Based on the Mean-Variance Model Including Uncertainty Factors
NASA Astrophysics Data System (ADS)
Hasuike, Takashi; Ishii, Hiroaki
2009-01-01
This paper considers robust programming problems based on the mean-variance model including uncertainty sets and fuzzy factors. Since these problems are not well-defined problems due to fuzzy factors, it is hard to solve them directly. Therefore, introducing chance constraints, fuzzy goals and possibility measures, the proposed models are transformed into the deterministic equivalent problems. Furthermore, in order to solve these equivalent problems efficiently, the solution method is constructed introducing the mean-absolute deviation and doing the equivalent transformations.
Checking ozone amounts by measurements of UV-irradiances
NASA Technical Reports Server (NTRS)
Seckmeyer, Gunther; Kettner, Christiane; Thiel, Stephen
1994-01-01
Absolute measurements of UV-irradiances in Germany and New Zealand are used to determine the total amounts of ozone. UV-irradiances measured and calculated for clear skies and for solar zenith angles less than 60 deg generally show a good accordance. The UVB-irradiances, however, show that the actual Dobson values are about 5 percent higher in Germany and about 3 percent higher in New Zealand compared to those obtained by our method. Possible reasons for these deviations are discussed.
[Systemic approach to radiobiological studies].
Bulanova, K Ia; Lobanok, L M
2004-01-01
The principles of information theory were applied for analysis of radiobiological effects. The perception of ionizing radiations as a signal enables living organism to discern their benefits or harm, to react to absolute and relatively small deviations, to keep the logic and chronicle of events, to use the former experience for reacting in presence, to forecast consequences. The systemic analysis of organism's response to ionizing radiations allows explaining the peculiarities of effects of different absorbed doses, hormesis, apoptosis, remote consequences and other post-radiation effects.
Falling Behind: New Evidence on the Black-White Achievement Gap
ERIC Educational Resources Information Center
Levitt, Steven D.; Fryer, Roland G.
2004-01-01
On average, black students typically score one standard deviation below white students on standardized tests--roughly the difference in performance between the average 4th grader and the average 8th grader. Historically, what has come to be known as the black-white test-score gap has emerged before children enter kindergarten and has tended to…
Measurement of the aerothermodynamic state in a high enthalpy plasma wind-tunnel flow
NASA Astrophysics Data System (ADS)
Hermann, Tobias; Löhle, Stefan; Zander, Fabian; Fasoulas, Stefanos
2017-11-01
This paper presents spatially resolved measurements of absolute particle densities of N2, N2+, N, O, N+ , O+ , e- and excitation temperatures of electronic, rotational and vibrational modes of an air plasma free stream. All results are based on optical emission spectroscopy data. The measured parameters are combined to determine the local mass-specific enthalpy of the free stream. The analysis of the radiative transport, relative and absolute intensities, and spectral shape is used to determine various thermochemical parameters. The model uncertainty of each analysis method is assessed. The plasma flow is shown to be close to equilibrium. The strongest deviations from equilibrium occur for N, N+ and N2+ number densities in the free stream. Additional measurements of the local mass-specific enthalpy are conducted using a mass injection probe as well as a heat flux and total pressure probe. The agreement between all methods of enthalpy determination is good.
Forecasting in foodservice: model development, testing, and evaluation.
Miller, J L; Thompson, P A; Orabella, M M
1991-05-01
This study was designed to develop, test, and evaluate mathematical models appropriate for forecasting menu-item production demand in foodservice. Data were collected from residence and dining hall foodservices at Ohio State University. Objectives of the study were to collect, code, and analyze the data; develop and test models using actual operation data; and compare forecasting results with current methods in use. Customer count was forecast using deseasonalized simple exponential smoothing. Menu-item demand was forecast by multiplying the count forecast by a predicted preference statistic. Forecasting models were evaluated using mean squared error, mean absolute deviation, and mean absolute percentage error techniques. All models were more accurate than current methods. A broad spectrum of forecasting techniques could be used by foodservice managers with access to a personal computer and spread-sheet and database-management software. The findings indicate that mathematical forecasting techniques may be effective in foodservice operations to control costs, increase productivity, and maximize profits.
ORBITAL SOLUTIONS AND ABSOLUTE ELEMENTS OF THE ECLIPSING BINARY EE AQUARII
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wronka, Marissa Diehl; Gold, Caitlin; Sowell, James R.
2010-04-15
EE Aqr is a 7.9 mag Algol variable with a 12 hr orbital period. The Wilson-Devinney program is used to simultaneously solve 11 previously published light curves together with two existing radial velocity curves. The resulting masses are M {sub 1} = 2.24 {+-} 0.13 M {sub sun} and M {sub 2} = 0.72 {+-} 0.04 M {sub sun}, and the radii are R {sub 1} = 1.76 {+-} 0.03 R {sub sun} and R {sub 2} = 1.10 {+-} 0.02 R {sub sun}. The system has the lower-mass component completely filling its Roche lobe. Its distance from Hipparcos observationsmore » is 112 {+-} 10 pc. An improved ephemeris is derived, and no deviations in the period over time were seen. Light and velocity curve parameters, orbital elements, and absolute dimensions are presented, plus a comparison is made with previous solutions.« less
Self-mixing instrument for simultaneous distance and speed measurement
NASA Astrophysics Data System (ADS)
Norgia, Michele; Melchionni, Dario; Pesatori, Alessandro
2017-12-01
A novel instrument based on Self-mixing interferometry is proposed to simultaneously measure absolute distance and velocity. The measurement method is designed for working directly on each kind of surface, in industrial environment, overcoming also problems due to speckle pattern effect. The laser pump current is modulated at quite high frequency (40 kHz) and the estimation of the induced fringes frequency allows an almost instantaneous measurement (measurement time equal to 25 μs). A real time digital elaboration processes the measurement data and discards unreliable measurements. The simultaneous measurement reaches a relative standard deviation of about 4·10-4 in absolute distance, and 5·10-3 in velocity measurement. Three different laser sources are tested and compared. The instrument shows good performances also in harsh environment, for example measuring the movement of an opaque iron tube rotating under a running water flow.
Early results from the Far Infrared Absolute Spectrophotometer (FIRAS)
NASA Technical Reports Server (NTRS)
Mather, J. C.; Cheng, E. S.; Shafer, R. A.; Eplee, R. E.; Isaacman, R. B.; Fixsen, D. J.; Read, S. M.; Meyer, S. S.; Weiss, R.; Wright, E. L.
1991-01-01
The Far Infrared Absolute Spectrophotometer (FIRAS) on the Cosmic Background Explorer (COBE) mapped 98 percent of the sky, 60 percent of it twice, before the liquid helium coolant was exhausted. The FIRAS covers the frequency region from 1 to 100/cm with a 7 deg angular resolution. The spectral resolution is 0.2/cm for frequencies less than 20/cm and 0.8/cm for higher frequencies. Preliminary results include: a limit on the deviations from a Planck curve of 1 percent of the peak brightness from 1 to 20/cm, a temperature of 2.735 +/- 0.06 K, a limit on the Comptonization parameter y of 0.001, on the chemical potential parameter mu of 0.01, a strong limit on the existence of a hot smooth intergalactic medium, and a confirmation that the dipole anisotropy spectrum is that of a Doppler shifted blackbody.
Real-Gas Correction Factors for Hypersonic Flow Parameters in Helium
NASA Technical Reports Server (NTRS)
Erickson, Wayne D.
1960-01-01
The real-gas hypersonic flow parameters for helium have been calculated for stagnation temperatures from 0 F to 600 F and stagnation pressures up to 6,000 pounds per square inch absolute. The results of these calculations are presented in the form of simple correction factors which must be applied to the tabulated ideal-gas parameters. It has been shown that the deviations from the ideal-gas law which exist at high pressures may cause a corresponding significant error in the hypersonic flow parameters when calculated as an ideal gas. For example the ratio of the free-stream static to stagnation pressure as calculated from the thermodynamic properties of helium for a stagnation temperature of 80 F and pressure of 4,000 pounds per square inch absolute was found to be approximately 13 percent greater than that determined from the ideal-gas tabulation with a specific heat ratio of 5/3.
The NIST Detector-Based Luminous Intensity Scale
Cromer, C. L.; Eppeldauer, G.; Hardis, J. E.; Larason, T. C.; Ohno, Y.; Parr, A. C.
1996-01-01
The Système International des Unités (SI) base unit for photometry, the candela, has been realized by using absolute detectors rather than absolute sources. This change in method permits luminous intensity calibrations of standard lamps to be carried out with a relative expanded uncertainty (coverage factor k = 2, and thus a 2 standard deviation estimate) of 0.46 %, almost a factor-of-two improvement. A group of eight reference photometers has been constructed with silicon photodiodes, matched with filters to mimic the spectral luminous efficiency function for photopic vision. The wide dynamic range of the photometers aid in their calibration. The components of the photometers were carefully measured and selected to reduce the sources of error and to provide baseline data for aging studies. Periodic remeasurement of the photometers indicate that a yearly recalibration is required. The design, characterization, calibration, evaluation, and application of the photometers are discussed. PMID:27805119
Absolute S- and P-plane polarization efficiencies for high frequency holographic gratings in the VUV
NASA Technical Reports Server (NTRS)
Caruso, A. J.; Woodgate, B. E.; Mount, G. H.
1981-01-01
High frequency plane gratings (3500 and 3600 gr/mm) have been holographically ruled and blazed for the VUV spectral region. All gratings were coated with 70 nm Al + 25 nm MgF2. Absolute unpolarized and S- and P-plane polarization efficiencies have been measured for the first and second orders in the 120- to 450-nm spectral region at 18.5 and 30 deg angles of deviation. For deep grooves, anomalous features are more pronounced for the P-plane polarization efficiency than for the S-plane polarization efficiency. Holographic gratings can be tailored to produce high polarization or low polarization in the VUV. For comparison, efficiencies and polarization of the best conventional high frequency gratings were also determined. Measurements show that scattered light is significantly lower for holographic gratings in the VUV when compared with the conventional gratings.
Position of the station Borowiec in the Doppler observation campaign WEDOC 80
NASA Astrophysics Data System (ADS)
Pachelski, W.
The position of the Doppler antenna located at the Borowiec Observatory, Poland, is analyzed based on data gathered during the WEDOC 80 study and an earlier study in 1977. Among other findings, it is determined that biases of the reference system origin can be partially eliminated by transforming absolute coordinates of two or more stations into station-to-station vector components, and by determining the vector length while the system scale remains affected by broadcast ephemerides. The standard deviations of absolute coordinates are shown to represent only the internal accuracy of the solution, and are found to depend on the geometrical configuration between the station position and the satellite passes. It is shown that significant correlations between station coordinates in translocation or multilocation are due to the poor conditioning of design matrices with respect to the origin and orientation of the reference system.
Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P
2012-12-05
Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in the frequency of malpositioned glenoid implants. Novel three-dimensional preoperative planning, coupled with patient and implant-specific instrumentation, allows the surgeon to better define the preoperative pathology, select the optimal implant design and location, and then accurately execute the plan at the time of surgery.
Mars Global Reference Atmospheric Model (Mars-GRAM) and Database for Mission Design
NASA Technical Reports Server (NTRS)
Justus, C. G.; Duvall, Aleta; Johnson, D. L.
2003-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many Mars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model, while above 80 km it is based on Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topography from Mars Global Surveyor Mars Orbiting Laser Altimeter. Validation studies are described comparing Mars-GRAM with Mars Global Surveyor Radio Science and Thermal Emission Spectrometer data. RS data from 2480 profiles were used, covering latitudes 75 deg S to 72 deg N, surface to approximately 40 km, for seasons ranging from areocentric longitude of Sun (Ls) = 70-160 deg and 265-310 deg. RS data spanned a range of local times, mostly 0-9 hours and 18-24 hours. For interests in aerocapture and precision landing, comparisons concentrated on atmospheric density. At a fixed height of 20 km, RS density varied by about a factor of 2.5 over ranges of latitudes and Ls values observed. Evaluated at matching positions and times, these figures show average RSMars-GRAM density ratios were generally 1+/-)0.05, except at heights above approximately 25 km and latitudes above approximately 50 deg N. Average standard deviation of RSMars-GRAM density ratio was 6%. TES data were used covering surface to approximately 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of a Mars global dust storm). Depending on season, TES data covered latitudes 85 deg S to 85 deg N. Most TES data were concentrated near local times 2 hours and 14 hours. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (greater than 45 deg N), or at most altitudes in the southern hemisphere at Ls approximately 90 and 180 deg. Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approximately 2.5% for all data, or approximately 1-4%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for local time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about three times the standard deviation of TES data about the TES mean value at a given position and season.
McCormick, Matthew M.; Madsen, Ernest L.; Deaner, Meagan E.; Varghese, Tomy
2011-01-01
Absolute backscatter coefficients in tissue-mimicking phantoms were experimentally determined in the 5–50 MHz frequency range using a broadband technique. A focused broadband transducer from a commercial research system, the VisualSonics Vevo 770, was used with two tissue-mimicking phantoms. The phantoms differed regarding the thin layers covering their surfaces to prevent desiccation and regarding glass bead concentrations and diameter distributions. Ultrasound scanning of these phantoms was performed through the thin layer. To avoid signal saturation, the power spectra obtained from the backscattered radio frequency signals were calibrated by using the signal from a liquid planar reflector, a water-brominated hydrocarbon interface with acoustic impedance close to that of water. Experimental values of absolute backscatter coefficients were compared with those predicted by the Faran scattering model over the frequency range 5–50 MHz. The mean percent difference and standard deviation was 54% ± 45% for the phantom with a mean glass bead diameter of 5.40 μm and was 47% ± 28% for the phantom with 5.16 μm mean diameter beads. PMID:21877789
Toussaint, Rebecca K.; Sage, G. Kevin; Talbot, Sandra L.; Scheel, David
2012-01-01
We isolated and developed 18 novel microsatellite markers for the giant Pacific octopus (Enteroctopus dofleini) and examined them for 31 individuals from Prince William Sound (PWS), Alaska. These loci displayed moderate levels of allelic diversity (averaging 11 alleles per locus) and heterozygosity (averaging 65%). Seven loci deviated from Hardy–Weinberg Equilibrium (HWE) due to heterozygote deficiency for the PWS population, although deviations were not observed for all these loci in other populations, suggesting the PWS population is not in mutation-drift equilibrium. These novel microsatellite loci yielded sufficient genetic diversity for potential use in population genetics, individual identification, and parentage studies.
Chung, Younshik; Chang, IlJoon
2015-11-01
Recently, the introduction of vehicle black box systems or in-vehicle video event data recorders enables the driver to use the system to collect more accurate crash information such as location, time, and situation at the pre-crash and crash moment, which can be analyzed to find the crash causal factors more accurately. This study presents the vehicle black box system in brief and its application status in Korea. Based on the crash data obtained from the vehicle black box system, this study analyzes the accuracy of the crash data collected from existing road crash data recording method, which has been recorded by police officers based on accident parties' statements or eyewitness's account. The analysis results show that the crash data observed by the existing method have an average of 84.48m of spatial difference and standard deviation of 157.75m as well as average 29.05min of temporal error and standard deviation of 19.24min. Additionally, the average and standard deviation of crash speed errors were found to be 9.03km/h and 7.21km/h, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.
Deviation-based spam-filtering method via stochastic approach
NASA Astrophysics Data System (ADS)
Lee, Daekyung; Lee, Mi Jin; Kim, Beom Jun
2018-03-01
In the presence of a huge number of possible purchase choices, ranks or ratings of items by others often play very important roles for a buyer to make a final purchase decision. Perfectly objective rating is an impossible task to achieve, and we often use an average rating built on how previous buyers estimated the quality of the product. The problem of using a simple average rating is that it can easily be polluted by careless users whose evaluation of products cannot be trusted, and by malicious spammers who try to bias the rating result on purpose. In this letter we suggest how trustworthiness of individual users can be systematically and quantitatively reflected to build a more reliable rating system. We compute the suitably defined reliability of each user based on the user's rating pattern for all products she evaluated. We call our proposed method as the deviation-based ranking, since the statistical significance of each user's rating pattern with respect to the average rating pattern is the key ingredient. We find that our deviation-based ranking method outperforms existing methods in filtering out careless random evaluators as well as malicious spammers.
Scanning laser polarimetry in eyes with exfoliation syndrome.
Dimopoulos, Antonios T; Katsanos, Andreas; Mikropoulos, Dimitrios G; Giannopoulos, Theodoros; Empeslidis, Theodoros; Teus, Miguel A; Holló, Gábor; Konstas, Anastasios G P
2013-01-01
To compare retinal nerve fiber layer thickness (RNFLT) of normotensive eyes with exfoliation syndrome (XFS) and healthy eyes. Sixty-four consecutive individuals with XFS and normal office-time intraocular pressure (IOP) and 72 consecutive healthy controls were prospectively enrolled for a cross-sectional analysis in this hospital-based observational study. The GDx-VCC parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, TSNIT standard deviation (SD), and nerve fiber indicator [NFI]) were compared between groups. Correlation between various clinical parameters and RNFLT parameters was investigated with Spearman coefficient. The NFI, although within normal limits for both groups, was significantly greater in the XFS group compared to controls: the respective median and interquartile range (IQR) values were 25.1 (22.0-29.0) vs 15.0 (12.0-20.0), p<0.001. In the XFS group, all RNFLT values were significantly lower compared to controls (p<0.001). However, they were all within the normal clinical ranges for both groups: TSNIT average median (IQR): 52.8 (49.7-55.7) vs 56.0 (53.0-59.3) µm; superior average mean (SD): 62.3 (6.7) vs 68.8 (8.2) µm; inferior average mean (SD): 58.0 (7.2) vs 64.8 (7.7) µm, respectively. TSNIT SD was significantly lower in the XFS group, median (IQR): 18.1 (15.4-20.4) vs 21.0 (18.4-23.8), p<0.001. There was no systematic relationship between RNFLT and visual acuity, cup-to-disc ratio, IOP, central corneal thickness, Humphrey mean deviation, and pattern standard deviation in either group. Compared to control eyes, polarimetry-determined RNFLT was lower in XFS eyes with normal IOP. Therefore, close monitoring of RNFLT may facilitate early identification of those XFS eyes that convert to exfoliative glaucoma.
Income inequality in the developing world.
Ravallion, Martin
2014-05-23
Should income inequality be of concern in developing countries? New data reveal less income inequality in the developing world than 30 years ago. However, this is due to falling inequality between countries. Average inequality within developing countries has been slowly rising, though staying fairly flat since 2000. As a rule, higher rates of growth in average incomes have not put upward pressure on inequality within countries. Growth has generally helped reduce the incidence of absolute poverty, but less so in more unequal countries. High inequality also threatens to stall future progress against poverty by attenuating growth prospects. Perceptions of rising absolute gaps in living standards between the rich and the poor in growing economies are also consistent with the evidence. Copyright © 2014, American Association for the Advancement of Science.
NASA Astrophysics Data System (ADS)
Massah, Mozhdeh; Kantz, Holger
2016-04-01
As we have one and only one earth and no replicas, climate characteristics are usually computed as time averages from a single time series. For understanding climate variability, it is essential to understand how close a single time average will typically be to an ensemble average. To answer this question, we study large deviation probabilities (LDP) of stochastic processes and characterize them by their dependence on the time window. In contrast to iid variables for which there exists an analytical expression for the rate function, the correlated variables such as auto-regressive (short memory) and auto-regressive fractionally integrated moving average (long memory) processes, have not an analytical LDP. We study LDP for these processes, in order to see how correlation affects this probability in comparison to iid data. Although short range correlations lead to a simple correction of sample size, long range correlations lead to a sub-exponential decay of LDP and hence to a very slow convergence of time averages. This effect is demonstrated for a 120 year long time series of daily temperature anomalies measured in Potsdam (Germany).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mampuya, Wambaka Ange; Nakamura, Mitsuhiro; Matsuo, Yukinori
2013-09-15
Purpose: To assess the effect of abdominal compression on the interfraction variation in tumor position in lung stereotactic body radiotherapy (SBRT) using cone-beam computed tomography (CBCT) in a larger series of patients with large tumor motion amplitude.Methods: Thirty patients with lung tumor motion exceeding 8 mm who underwent SBRT were included in this study. After translational and rotational initial setup error was corrected based on bone anatomy, CBCT images were acquired for each fraction. The residual interfraction variation was defined as the difference between the centroid position of the visualized target in three dimensions derived from CBCT scans and thosemore » derived from averaged intensity projection images. The authors compared the magnitude of the interfraction variation in tumor position between patients treated with [n= 16 (76 fractions)] and without [n= 14 (76 fractions)] abdominal compression.Results: The mean ± standard deviation (SD) of the motion amplitude in the longitudinal direction before abdominal compression was 19.9 ± 7.3 (range, 10–40) mm and was significantly (p < 0.01) reduced to 12.4 ± 5.8 (range, 5–30) mm with compression. The greatest variance of the interfraction variation with abdominal compression was observed in the longitudinal direction, with a mean ± SD of 0.79 ± 3.05 mm, compared to −0.60 ± 2.10 mm without abdominal compression. The absolute values of the 95th percentile of the interfraction variation for one side in each direction were 3.97/6.21 mm (posterior/anterior), 4.16/3.76 mm (caudal/cranial), and 2.90/2.32 mm (right/left) without abdominal compression, and 2.14/5.03 mm (posterior/anterior), 3.93/9.23 mm (caudal/cranial), and 2.37/5.45 mm (right/left) with abdominal compression. An absolute interfraction variation greater than 5 mm was observed in six (9.2%) fractions without and 13 (17.1%) fractions with abdominal compression.Conclusions: Abdominal compression was effective for reducing the amplitude of tumor motion. However, in most of the authors’ patients, the use of abdominal compression seemed to increase the interfraction variation in tumor position, despite reducing lung tumor motion. The daily tumor position deviated more systematically from the tumor position in the planning CT scan in the lateral and longitudinal directions in patients treated with abdominal compression compared to those treated without compression. Therefore, target matching is required to correct or minimize the interfraction variation.« less
NASA Astrophysics Data System (ADS)
Bernhard, G.; Dahlback, A.; Fioletov, V.; Heikkilä, A.; Johnsen, B.; Koskela, T.; Lakkala, K.; Svendby, T.
2013-11-01
Greatly increased levels of ultraviolet (UV) radiation were observed at thirteen Arctic and sub-Arctic ground stations in the spring of 2011, when the ozone abundance in the Arctic stratosphere dropped to the lowest amounts on record. Measurements of the noontime UV Index (UVI) during the low-ozone episode exceeded the climatological mean by up to 77% at locations in the western Arctic (Alaska, Canada, Greenland) and by up to 161% in Scandinavia. The UVI measured at the end of March at the Scandinavian sites was comparable to that typically observed 15-60 days later in the year when solar elevations are much higher. The cumulative UV dose measured during the period of the ozone anomaly exceeded the climatological mean by more than two standard deviations at 11 sites. Enhancements beyond three standard deviations were observed at seven sites and increases beyond four standard deviations at two sites. At the western sites, the episode occurred in March, when the Sun was still low in the sky, limiting absolute UVI anomalies to less than 0.5 UVI units. At the Scandinavian sites, absolute UVI anomalies ranged between 1.0 and 2.2 UVI units. For example, at Finse, Norway, the noontime UVI on 30 March was 4.7, while the climatological UVI is 2.5. Although a UVI of 4.7 is still considered moderate, UV levels of this amount can lead to sunburn and photokeratitis during outdoor activity when radiation is reflected upward by snow towards the face of a person or animal. At the western sites, UV anomalies can be well explained with ozone anomalies of up to 41% below the climatological mean. At the Scandinavian sites, low ozone can only explain a UVI increase of 50-60%. The remaining enhancement was mainly caused by the absence of clouds during the low-ozone period.
NASA Astrophysics Data System (ADS)
Bernhard, G.; Dahlback, A.; Fioletov, V.; Heikkilä, A.; Johnsen, B.; Koskela, T.; Lakkala, K.; Svendby, T. M.
2013-06-01
Greatly increased levels of ultraviolet (UV) radiation were observed at thirteen Arctic and sub-Arctic ground stations in the spring of 2011 when the ozone abundance in the Arctic stratosphere dropped to the lowest amounts on record. Measurements of the noontime UV Index (UVI) during the low-ozone episode exceeded the climatological mean by up to 77% at locations in the western Arctic (Alaska, Canada, Greenland) and by up to 161% in Scandinavia. The UVI measured at the end of March at the Scandinavian sites was comparable to that typically observed 15-60 days later in the year when solar elevations are much higher. The cumulative UV dose measured during the period of the ozone anomaly exceeded the climatological mean by more than two standard deviations at 11 sites. Enhancements beyond three standard deviations were observed at seven sites and increases beyond four standard deviations at two sites. At the western sites, the episode occurred in March when the Sun was still low in the sky, limiting absolute UVI anomalies to less than 0.5 UVI units. At the Scandinavian sites, absolute UVI anomalies ranged between 1.0 and 2.2 UVI units. For example, at Finse, Norway, the noontime UVI on 30 March was 4.7 while the climatological UVI is 2.5. Although a UVI of 4.7 is still considered moderate, UV levels of this amount can lead to sunburn and photokeratitis during outdoor activity when radiation is reflected upward by snow towards the face of a person or animal. At the western sites, UV anomalies can be well explained with ozone anomalies of up to 41% below the climatological mean. At the Scandinavian sites, low ozone can only explain a UVI increase by 50-60%. The remaining enhancement was mainly caused by the absence of clouds during the low-ozone period.
Variations in Daily Sleep Quality and Type 1 Diabetes Management in Late Adolescents
Queen, Tara L.; Butner, Jonathan; Wiebe, Deborah; Berg, Cynthia A.
2016-01-01
Objective To determine how between- and within-person variability in perceived sleep quality were associated with adolescent diabetes management. Methods A total of 236 older adolescents with type 1 diabetes reported daily for 2 weeks on sleep quality, self-regulatory failures, frequency of blood glucose (BG) checks, and BG values. Average, inconsistent, and daily deviations in sleep quality were examined. Results Hierarchical linear models indicated that poorer average and worse daily perceived sleep quality (compared with one’s average) was each associated with more self-regulatory failures. Sleep quality was not associated with frequency of BG checking. Poorer average sleep quality was related to greater risk of high BG. Furthermore, inconsistent and daily deviations in sleep quality interacted to predict higher BG, with more consistent sleepers benefitting more from a night of high-quality sleep. Conclusions Good, consistent sleep quality during late adolescence may benefit diabetes management by reducing self-regulatory failures and risk of high BG. PMID:26994852
Lantry, B.F.; Rudstam, L. G.; Forney, J.L.; VanDeValk, A.J.; Mills, E.L.; Stewart, D.J.; Adams, J.V.
2008-01-01
Daily consumption was estimated from the stomach contents of walleyes Sander vitreus collected weekly from Oneida Lake, New York, during June-October 1975, 1992, 1993, and 1994 for one to four age-groups per year. Field rations were highly variable between weeks, and trends in ration size varied both seasonally and annually. The coefficient of variation for weekly field rations within years and ages ranged from 45% to 97%. Field estimates were compared with simulated consumption from a bioenergetics model. The simulation averages of daily ration deviated from those of the field estimates by -20.1% to +70.3%, with a mean across all simulations of +14.3%. The deviations for each time step were much greater than those for the simulation averages, ranging from -92.8% to +363.6%. A systematic trend in the deviations was observed, the model producing overpredictions at rations less than 3.7% of body weight. Analysis of variance indicated that the deviations were affected by sample year and week but not age. Multiple linear regression using backwards selection procedures and Akaike's information criterion indicated that walleye weight, walleye growth, lake temperature, prey energy density, and the proportion of gizzard shad Dorosoma cepedianum in the diet significantly affected the deviations between simulated and field rations and explained 32% of the variance. ?? Copyright by the American Fisheries Society 2008.
Dosimetry audit simulation of treatment planning system in multicenters radiotherapy
NASA Astrophysics Data System (ADS)
Kasmuri, S.; Pawiro, S. A.
2017-07-01
Treatment Planning System (TPS) is an important modality that determines radiotherapy outcome. TPS requires input data obtained through commissioning and the potentially error occurred. Error in this stage may result in the systematic error. The aim of this study to verify the TPS dosimetry to know deviation range between calculated and measurement dose. This study used CIRS phantom 002LFC representing the human thorax and simulated all external beam radiotherapy stages. The phantom was scanned using CT Scanner and planned 8 test cases that were similar to those in clinical practice situation were made, tested in four radiotherapy centers. Dose measurement using 0.6 cc ionization chamber. The results of this study showed that generally, deviation of all test cases in four centers was within agreement criteria with average deviation about -0.17±1.59 %, -1.64±1.92 %, 0.34±1.34 % and 0.13±1.81 %. The conclusion of this study was all TPS involved in this study showed good performance. The superposition algorithm showed rather poor performance than either analytic anisotropic algorithm (AAA) and convolution algorithm with average deviation about -1.64±1.92 %, -0.17±1.59 % and -0.27±1.51 % respectively.
Measurements of Ultra-Stable Oscillator (USO) Allan Deviations in Space
NASA Technical Reports Server (NTRS)
Enzer, Daphna G.; Klipstein, William M.; Wang, Rabi T.; Dunn, Charles E.
2013-01-01
Researchers have used data from the GRAIL mission to the Moon to make the first in-flight verification of ultra-stable oscillators (USOs) with Allan deviation below 10 13 for 1-to-100-second averaging times. USOs are flown in space to provide stable timing and/or navigation signals for a variety of different science and programmatic missions. The Gravity Recovery and Interior Laboratory (GRAIL) mission is flying twin spacecraft, each with its own USO and with a Ka-band crosslink used to measure range fluctuations. Data from this crosslink can be combined in such a way as to give the relative time offsets of the two spacecrafts USOs and to calculate the Allan deviation to describe the USOs combined performance while orbiting the Moon. Researchers find the first direct in-space Allan deviations below 10(exp -13) for 1-to-100-second averaging times comparable to pre-launch data, and better than measurements from ground tracking of an X-band carrier coherent with the USO. Fluctuations in Earth s atmosphere limit measurement performance in direct-to-Earth links. Inflight USO performance verification was also performed for GRAIL s parent mission, the Gravity Recovery and Climate Experiment (GRACE), using both Kband and Ka-band crosslinks.
NASA Technical Reports Server (NTRS)
Raj, Sai V.
2014-01-01
Thermal expansion measurements were conducted on hot-pressed CrSi(sub 2), TiSi(sub 2), W Si(sub 2) and a two-phase Cr-Mo-Si intermetallic alloy between 293 and 1523 K during three heat-cool cycles. The corrected thermal expansion, (L/L(sub 0)(sub thermal), varied with the absolute temperature, T, as (deltaL/L(sub 0)(sub thermal) = A(T-293)(sup 3) + B(T-293)(sup 2) + C(T-293) + D, where A, B, C and D are regression constants. Excellent reproducibility was observed for most of the materials after the first heat-up cycle. In some cases, the data from the first heatup cycle deviated from those determined in the subsequent cycles. This deviation was attributed to the presence of residual stresses developed during processing, which are relieved after the first heat-up cycle.
NASA Astrophysics Data System (ADS)
Blue, Alan S.; Belyung, David P.; Fontijn, Arthur
1997-09-01
Semiempirical configuration interaction (SECI) theory is used to predict activation barriers E, as defined by k(T)=ATn exp(-E/RT). Previously SECI has been applied to homologous series of oxidation reactions of s1, s2, and s2p1 metal atoms. Here it is extended to oxidation reactions of diatomic molecules containing one s2p1 atom. E values are calculated for the reactions of BH, BF, BCl, AlF, AlCl, AlBr, GaF, GaI, InCl, InBr, InI, TlF, TlCl, TlBr, and TlI with O2, CO2, SO2, or N2O. These values correlate with the sums of the ionization potentials and Σ-Π promotion energies of the former minus the electron affinities of the latter. In the earlier work n was chosen somewhat arbitrarily, which affected the absolute values of E. Here it is shown that examination of available experimental and theoretical results allows determination of the best values of n. Using this approach yields n=1.9 for the present series. For the seven reactions which have been studied experimentally, the average deviation of the SECI activation barrier prediction from experiment is 4.0 kJ mol-1. Energy barriers are calculated for another 52 reactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stow, Sarah M.; Causon, Tim J.; Zheng, Xueyun
Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on amore » commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.« less
NASA Astrophysics Data System (ADS)
POP, A. B.; ȚÎȚU, M. A.
2016-11-01
In the metal cutting process, surface quality is intrinsically related to the cutting parameters and to the cutting tool geometry. At the same time, metal cutting processes are closely related to the machining costs. The purpose of this paper is to reduce manufacturing costs and processing time. A study was made, based on the mathematical modelling of the average of the absolute value deviation (Ra) resulting from the end milling process on 7136 aluminium alloy, depending on cutting process parameters. The novel element brought by this paper is the 7136 aluminium alloy type, chosen to conduct the experiments, which is a material developed and patented by Universal Alloy Corporation. This aluminium alloy is used in the aircraft industry to make parts from extruded profiles, and it has not been studied for the proposed research direction. Based on this research, a mathematical model of surface roughness Ra was established according to the cutting parameters studied in a set experimental field. A regression analysis was performed, which identified the quantitative relationships between cutting parameters and the surface roughness. Using the variance analysis ANOVA, the degree of confidence for the achieved results by the regression equation was determined, and the suitability of this equation at every point of the experimental field.
NASA Astrophysics Data System (ADS)
Motevasel, Mohsen; Nazar, Ali Reza Solaimany; Jamialahmadi, Mohammad
2018-01-01
Nanoparticles suspended in a base fluid yield increased thermal conductivity, which in turn increases convection heat transfer rate. Prediction of suitable relations for determination of thermal conductivity results in heightened accuracy in the calculation of convection heat transfer coefficient and reduced costs. In the majority of studies performed on the prediction of thermal conductivity, some relations and models were used in which the effect of aggregation of particles, especially at low concentrations was ignored. In this research, the thermal conductivity of the nanofluid is measured experimentally at low volumetric concentrations, within the range of 0.02-0.2% for the nanoparticles of Al2O3, MgO, CuO, and SiC in the base fluid of distilled water. The results obtained from the models are compared by the available models considering and neglecting the effect of aggregation of particles. Within the range of the applied concentrations, the relative absolute average deviation ratio of the thermal conductivity models without considering the aggregation effect in relation with the models considering the aggregate, is observed to be between 2 and 6 times. Therefore, it is recommended that even at low concentrations, the effect of aggregation should be considered in the prediction of thermal conductivity.
Sand dune ridge alignment effects on surface BRF over the Libya-4 CEOS calibration site.
Govaerts, Yves M
2015-02-03
The Libya-4 desert area, located in the Great Sand Sea, is one of the most important bright desert CEOS pseudo-invariant calibration sites by its size and radiometric stability. This site is intensively used for radiometer drift monitoring, sensor intercalibration and as an absolute calibration reference based on simulated radiances traceable to the SI standard. The Libya-4 morphology is composed of oriented sand dunes shaped by dominant winds. The effects of sand dune spatial organization on the surface bidirectional reflectance factor is analyzed in this paper using Raytran, a 3D radiative transfer model. The topography is characterized with the 30 m resolution ASTER digital elevation model. Four different regions-of-interest sizes, ranging from 10 km up to 100 km, are analyzed. Results show that sand dunes generate more backscattering than forward scattering at the surface. The mean surface reflectance averaged over different viewing and illumination angles is pretty much independent of the size of the selected area, though the standard deviation differs. Sun azimuth position has an effect on the surface reflectance field, which is more pronounced for high Sun zenith angles. Such 3D azimuthal effects should be taken into account to decrease the simulated radiance uncertainty over Libya-4 below 3% for wavelengths larger than 600 nm.
A Prediction Method of Binding Free Energy of Protein and Ligand
NASA Astrophysics Data System (ADS)
Yang, Kun; Wang, Xicheng
2010-05-01
Predicting the binding free energy is an important problem in bimolecular simulation. Such prediction would be great benefit in understanding protein functions, and may be useful for computational prediction of ligand binding strengths, e.g., in discovering pharmaceutical drugs. Free energy perturbation (FEP)/thermodynamics integration (TI) is a classical method to explicitly predict free energy. However, this method need plenty of time to collect datum, and that attempts to deal with some simple systems and small changes of molecular structures. Another one for estimating ligand binding affinities is linear interaction energy (LIE) method. This method employs averages of interaction potential energy terms from molecular dynamics simulations or other thermal conformational sampling techniques. Incorporation of systematic deviations from electrostatic linear response, derived from free energy perturbation studies, into the absolute binding free energy expression significantly enhances the accuracy of the approach. However, it also is time-consuming work. In this paper, a new prediction method based on steered molecular dynamics (SMD) with direction optimization is developed to compute binding free energy. Jarzynski's equality is used to derive the PMF or free-energy. The results for two numerical examples are presented, showing that the method has good accuracy and efficiency. The novel method can also simulate whole binding proceeding and give some important structural information about development of new drugs.
Viscosity Prediction for Petroleum Fluids Using Free Volume Theory and PC-SAFT
NASA Astrophysics Data System (ADS)
Khoshnamvand, Younes; Assareh, Mehdi
2018-04-01
In this study, free volume theory ( FVT) in combination with perturbed-chain statistical associating fluid theory is implemented for viscosity prediction of petroleum reservoir fluids containing ill-defined components such as cuts and plus fractions. FVT has three adjustable parameters for each component to calculate viscosity. These three parameters for petroleum cuts (especially plus fractions) are not available. In this work, these parameters are determined for different petroleum fractions. A model as a function of molecular weight and specific gravity is developed using 22 real reservoir fluid samples with API grades in the range of 22 to 45. Afterward, the proposed model accuracy in comparison with the accuracy of De la Porte et al. with reference to experimental data is presented. The presented model is used for six real samples in an evaluation step, and the results are compared with available experimental data and the method of De la Porte et al. Finally, the method of Lohrenz et al. and the method of Pedersen et al. as two common industrial methods for viscosity calculation are compared with the proposed approach. The absolute average deviation was 9.7 % for free volume theory method, 15.4 % for Lohrenz et al., and 22.16 for Pedersen et al.
Comparison of GPS receiver DCB estimation methods using a GPS network
NASA Astrophysics Data System (ADS)
Choi, Byung-Kyu; Park, Jong-Uk; Min Roh, Kyoung; Lee, Sang-Jeong
2013-07-01
Two approaches for receiver differential code biases (DCB) estimation using the GPS data obtained from the Korean GPS network (KGN) in South Korea are suggested: the relative and single (absolute) methods. The relative method uses a GPS network, while the single method determines DCBs from a single station only. Their performance was assessed by comparing the receiver DCB values obtained from the relative method with those estimated by the single method. The daily averaged receiver DCBs obtained from the two different approaches showed good agreement for 7 days. The root mean square (RMS) value of those differences is 0.83 nanoseconds (ns). The standard deviation of the receiver DCBs estimated by the relative method was smaller than that of the single method. From these results, it is clear that the relative method can obtain more stable receiver DCBs compared with the single method over a short-term period. Additionally, the comparison between the receiver DCBs obtained by the Korea Astronomy and Space Science Institute (KASI) and those of the IGS Global Ionosphere Maps (GIM) showed a good agreement at 0.3 ns. As the accuracy of DCB values significantly affects the accuracy of ionospheric total electron content (TEC), more studies are needed to ensure the reliability and stability of the estimated receiver DCBs.
2012-01-01
Background The robust identification of isotope patterns originating from peptides being analyzed through mass spectrometry (MS) is often significantly hampered by noise artifacts and the interference of overlapping patterns arising e.g. from post-translational modifications. As the classification of the recorded data points into either ‘noise’ or ‘signal’ lies at the very root of essentially every proteomic application, the quality of the automated processing of mass spectra can significantly influence the way the data might be interpreted within a given biological context. Results We propose non-negative least squares/non-negative least absolute deviation regression to fit a raw spectrum by templates imitating isotope patterns. In a carefully designed validation scheme, we show that the method exhibits excellent performance in pattern picking. It is demonstrated that the method is able to disentangle complicated overlaps of patterns. Conclusions We find that regularization is not necessary to prevent overfitting and that thresholding is an effective and user-friendly way to perform feature selection. The proposed method avoids problems inherent in regularization-based approaches, comes with a set of well-interpretable parameters whose default configuration is shown to generalize well without the need for fine-tuning, and is applicable to spectra of different platforms. The R package IPPD implements the method and is available from the Bioconductor platform (http://bioconductor.fhcrc.org/help/bioc-views/devel/bioc/html/IPPD.html). PMID:23137144
He, Pengbo; Li, Qiang; Liu, Xinguo; Dai, Zhongying; Zhao, Ting; Fu, Tingyan; Shen, Guosheng; Ma, Yuanyuan; Huang, Qiyan; Yan, Yuanlin
2014-01-01
Purpose: To efficiently deliver respiratory-gated radiation during synchrotron-based pulsed heavy-ion radiotherapy, a novel respiratory guidance method combining a personalized audio-visual biofeedback (BFB) system, breath hold (BH), and synchrotron-based gating was designed to help patients synchronize their respiratory patterns with synchrotron pulses and to overcome typical limitations such as low efficiency, residual motion, and discomfort. Methods: In-house software was developed to acquire body surface marker positions and display BFB, gating signals, and real-time beam profiles on a LED screen. Patients were prompted to perform short BHs or short deep breath holds (SDBH) with the aid of BFB following a personalized standard BH/SDBH (stBH/stSDBH) guiding curve or their own representative BH/SDBH (reBH/reSDBH) guiding curve. A practical simulation was performed for a group of 15 volunteers to evaluate the feasibility and effectiveness of this method. Effective dose rates (EDRs), mean absolute errors between the guiding curves and the measured curves, and mean absolute deviations of the measured curves were obtained within 10%–50% duty cycles (DCs) that were synchronized with the synchrotron’s flat-top phase. Results: All maneuvers for an individual volunteer took approximately half an hour, and no one experienced discomfort during the maneuvers. Using the respiratory guidance methods, the magnitude of residual motion was almost ten times less than during nongated irradiation, and increases in the average effective dose rate by factors of 2.39–4.65, 2.39–4.59, 1.73–3.50, and 1.73–3.55 for the stBH, reBH, stSDBH, and reSDBH guiding maneuvers, respectively, were observed in contrast with conventional free breathing-based gated irradiation, depending on the respiratory-gated duty cycle settings. Conclusions: The proposed respiratory guidance method with personalized BFB was confirmed to be feasible in a group of volunteers. Increased effective dose rate and improved overall treatment precision were observed compared to conventional free breathing-based, respiratory-gated irradiation. Because breathing guidance curves could be established based on the respective average respiratory period and amplitude for each patient, it may be easier for patients to cooperate using this technique. PMID:25370622
Kinanthropometric profile of Cuban women Olympic volleyball champions.
Carvajal, Wiliam; Betancourt, Hamlet; León, Sofia; Deturnel, Yanel; Martínez, Miriam; Echevarría, Ivis; Castillo, María Eugenia; Serviat, Noemí
2012-04-01
Athletes' kinanthropometric profiles are widely addressed in the scientific literature. Such profiles are particularly important in volleyball because absolute size contributes a significant percentage of total variance associated with athletic success. As in other team sports, volleyball players' kinanthropometric attributes correlate with the game's tactical demands. From 1992 through 2000, the Cuban women's volleyball team achieved top global performance, winning first place in three successive Summer Olympic Games. Describe the kinanthropometric profiles of Cuban women Olympic volleyball champions during 1992-2000 and compare these by position played. Measurements were taken of body composition, somatotype, proportionality and several anthropometric indicators in 41 Cuban women volleyball players, grouped by playing position. All were members of the national team that participated in the Summer Olympic Games in Barcelona (1992), Atlanta (1996) and Sydney (2000). Mean and standard deviations were calculated for all study variables. Analysis of variance was used to compare means for different positions for the variables weight; height; percent adipose, muscle and bone mass; body mass index; and muscle-to-bone ratio. Discriminant analysis was performed to identify anthropometric dimensions differentiating playing positions (center, spiker and setter), using p<0.05 as significance threshold. Results were presented in tables and figures. Centers presented greater absolute size and higher average adipose (22.8±1.7 kg) and bone (7.1±0.6 kg) mass. The mean somatotype of all volleyball players was balanced mesomorphic (2.7-3.6-2.9). Classified by position, centers (2.9-3.4-3.4) and spikers (2.8-3.6-2.9) presented an average mesomorphic-ectomorphic somatotype, and setters (2.6-3.7-2.6) were balanced mesomorphic. On assessing Somatotype Attitudinal Mean (SAM), centers and spikers showed more intrapositional homogeneity than that of setters. Centers were significantly taller (187.1±2.5 cm) than players in other positions. Centers' percent adipose tissue mass (28.9±2.7%) was significantly higher than that of setters (24.3±2.7%), who were leanest of all positions. The kinanthropometric profile of Cuban women Olympic volleyball champions was defined by considerable muscular-skeletal development, with a predominantly mesomorphic somatotype and low endomorphy. Height and body composition varied significantly by playing position.
Müller, Erich A; Mejía, Andrés
2017-10-24
The statistical associating fluid theory of variable range employing a Mie potential (SAFT-VR-Mie) proposed by Lafitte et al. (J. Chem Phys. 2013, 139, 154504) is one of the latest versions of the SAFT family. This particular version has been shown to have a remarkable capability to connect experimental determinations, theoretical calculations, and molecular simulations results. However, the theoretical development restricts the model to chains of beads connected in a linear fashion. In this work, the capabilities of the SAFT-VR Mie equation of state for modeling phase equilibria are extended for the case of planar ring compounds. This modification proposed replaces the Helmholtz energy of chain formation by an empirical contribution based on a parallelism to the second-order thermodynamic perturbation theory for hard sphere trimers. The proposed expression is given in terms of an extra parameter, χ, that depends on the number of beads, m s , and the geometry of the ring. The model is used to describe the phase equilibrium for planar ring compounds formed of Mie isotropic segments for the cases of m s equals to 3, 4, 5 (two configurations), and 7 (two configurations). The resulting molecular model is further parametrized, invoking a corresponding states principle resulting in sets of parameters that can be used indistinctively in theoretical calculations or in molecular simulations without any further refinements. The extent and performance of the methodology has been exemplified by predicting the phase equilibria and vapor pressure curves for aromatic hydrocarbons (benzene, hexafluorobenzene, toluene), heterocyclic molecules (2,5-dimethylfuran, sulfolane, tetrahydro-2H-pyran, tetrahydrofuran), and polycyclic aromatic hydrocarbons (naphthalene, pyrene, anthracene, pentacene, and coronene). An important aspect of the theory is that the parameters of the model can be used directly in molecular dynamics (MD) simulations to calculate equilibrium phase properties and interfacial tensions with an accuracy that rivals other coarse grained and united atom models, for example, liquid densities, are predicted, with a maximum absolute average deviation of 3% from both the theory and the MD simulations, while the interfacial tension is predicted, with a maximum absolute average of 8%. The extension to mixtures is exemplified by considering a binary system of hexane (chain fluid) and tetrahydro-2H-pyran (ring fluid).
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Pengbo; Ma, Yuanyuan; Huang, Qiyan
Purpose: To efficiently deliver respiratory-gated radiation during synchrotron-based pulsed heavy-ion radiotherapy, a novel respiratory guidance method combining a personalized audio-visual biofeedback (BFB) system, breath hold (BH), and synchrotron-based gating was designed to help patients synchronize their respiratory patterns with synchrotron pulses and to overcome typical limitations such as low efficiency, residual motion, and discomfort. Methods: In-house software was developed to acquire body surface marker positions and display BFB, gating signals, and real-time beam profiles on a LED screen. Patients were prompted to perform short BHs or short deep breath holds (SDBH) with the aid of BFB following a personalized standardmore » BH/SDBH (stBH/stSDBH) guiding curve or their own representative BH/SDBH (reBH/reSDBH) guiding curve. A practical simulation was performed for a group of 15 volunteers to evaluate the feasibility and effectiveness of this method. Effective dose rates (EDRs), mean absolute errors between the guiding curves and the measured curves, and mean absolute deviations of the measured curves were obtained within 10%–50% duty cycles (DCs) that were synchronized with the synchrotron’s flat-top phase. Results: All maneuvers for an individual volunteer took approximately half an hour, and no one experienced discomfort during the maneuvers. Using the respiratory guidance methods, the magnitude of residual motion was almost ten times less than during nongated irradiation, and increases in the average effective dose rate by factors of 2.39–4.65, 2.39–4.59, 1.73–3.50, and 1.73–3.55 for the stBH, reBH, stSDBH, and reSDBH guiding maneuvers, respectively, were observed in contrast with conventional free breathing-based gated irradiation, depending on the respiratory-gated duty cycle settings. Conclusions: The proposed respiratory guidance method with personalized BFB was confirmed to be feasible in a group of volunteers. Increased effective dose rate and improved overall treatment precision were observed compared to conventional free breathing-based, respiratory-gated irradiation. Because breathing guidance curves could be established based on the respective average respiratory period and amplitude for each patient, it may be easier for patients to cooperate using this technique.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, G; Ha, J; Zhou, S
Purpose: To examine and validate the absolute dose for total skin electron therapy (TSET) through an end-to-end test with a Rando phantom using optically stimulated luminescent dosimeters (OSLDs) and EBT3 radiochromic films. Methods: A Varian Trilogy linear accelerator equipped with the special procedure 6 MeV HDTSe- was used to perform TSET irradiations using a modified Stanford 6-dual-field technique. The absolute dose was calibrated using a Markus ion chamber at a reference depth of 1.3cm at 100 cm SSD with a field size of 36 × 36 cm at the isocenter in solid water slabs. The absolute dose was cross validatedmore » by a farmer ion chamber. Then the dose rate in the unit of cGy/Mu was calibrated using the Markus chamber at the treatment position. OSLDs were used to independently verify the dose using the calibrated dose rate. Finally, a patient treatment plan (200 cGy/cycle) was delivered in the QA mode to a Rando phantom, which had 16 pairs of OSLDs and EBT3 films taped onto its surface at different anatomical positions. The doses recorded were read out to validate the absolute dosimetry for TSET. Results: The OSLD measurements were within 7% agreement with the planned dose except the shoulder areas, where the doses recorded were 23% lower on average than those of the planned. The EBT3 film measurements were within 10% agreement with the planned dose except the shoulder and the scalp vertex areas, where the respective doses recorded were 18% and 14% lower on average than those of the planned. The OSLDs gave more consistent dose measurements than those of the EBT3 films. Conclusion: The absolute dosimetry for TSET was validated by an end-to-end test with a Rando phantom using the OSLDs and EBT3 films. The beam calibration and monitor unit calculations were confirmed.« less
A system for automatic aorta sections measurements on chest CT
NASA Astrophysics Data System (ADS)
Pfeffer, Yitzchak; Mayer, Arnaldo; Zholkover, Adi; Konen, Eli
2016-03-01
A new method is proposed for caliber measurement of the ascending aorta (AA) and descending aorta (DA). A key component of the method is the automatic detection of the carina, as an anatomical landmark around which an axial volume of interest (VOI) can be defined to observe the aortic caliber. For each slice in the VOI, a linear profile line connecting the AA with the DA is found by pattern matching on the underlying intensity profile. Next, the aortic center position is found using Hough transform on the best linear segment candidate. Finally, region growing around the center provides an accurate segmentation and caliber measurement. We evaluated the algorithm on 113 sequential chest CT scans, slice thickness of 0.75 - 3.75mm, 90 with contrast agent injected. The algorithm success rates were computed as the percentage of scans in which the center of the AA was found. Automated measurements of AA caliber were compared with independent measurements of two experienced chest radiologists, comparing the absolute difference between the two radiologists with the absolute difference between the algorithm and each of the radiologists. The measurement stability was demonstrated by computing the STD of the absolute difference between the radiologists, and between the algorithm and the radiologists. Results: Success rates of 93% and 74% were achieved, for contrast injected cases and non-contrast cases, respectively. These results indicate that the algorithm can be robust in large variability of image quality, such as the cases in a realworld clinical setting. The average absolute difference between the algorithm and the radiologists was 1.85mm, lower than the average absolute difference between the radiologists, which was 2.1mm. The STD of the absolute difference between the algorithm and the radiologists was 1.5mm vs 1.6mm between the two radiologists. These results demonstrate the clinical relevance of the algorithm measurements.
Murray, Louise; Mason, Joshua; Henry, Ann M; Hoskin, Peter; Siebert, Frank-Andre; Venselaar, Jack; Bownes, Peter
2016-08-01
To estimate the risks of radiation-induced rectal and bladder cancers following low dose rate (LDR) and high dose rate (HDR) brachytherapy as monotherapy for localised prostate cancer and compare to external beam radiotherapy techniques. LDR and HDR brachytherapy monotherapy plans were generated for three prostate CT datasets. Second cancer risks were assessed using Schneider's concept of organ equivalent dose. LDR risks were assessed according to a mechanistic model and a bell-shaped model. HDR risks were assessed according to a bell-shaped model. Relative risks and excess absolute risks were estimated and compared to external beam techniques. Excess absolute risks of second rectal or bladder cancer were low for both LDR (irrespective of the model used for calculation) and HDR techniques. Average excess absolute risks of rectal cancer for LDR brachytherapy according to the mechanistic model were 0.71 per 10,000 person-years (PY) and 0.84 per 10,000 PY respectively, and according to the bell-shaped model, were 0.47 and 0.78 per 10,000 PY respectively. For HDR, the average excess absolute risks for second rectal and bladder cancers were 0.74 and 1.62 per 10,000 PY respectively. The absolute differences between techniques were very low and clinically irrelevant. Compared to external beam prostate radiotherapy techniques, LDR and HDR brachytherapy resulted in the lowest risks of second rectal and bladder cancer. This study shows both LDR and HDR brachytherapy monotherapy result in low estimated risks of radiation-induced rectal and bladder cancer. LDR resulted in lower bladder cancer risks than HDR, and lower or similar risks of rectal cancer. In absolute terms these differences between techniques were very small. Compared to external beam techniques, second rectal and bladder cancer risks were lowest for brachytherapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Modeling of the influence of humidity on H1N1 flu in China
NASA Astrophysics Data System (ADS)
PEI, Y.; Tian, H.; Xu, B.
2015-12-01
In 2009, a heavy Flu hit the whole world. It was caused by the virus H1N1. The influenza first broke out in Mexico in March and the United States in April, 2009. The World Health Organization (WHO) announced that the H1N1 influenza became pandemic, alert to a warning phase of six. By the end of 2011, 181302 H1N1 cases were reported in mainland China. To improve our understanding on the impact of environmental factors on the disease transmission, we constructed an SIR (Susceptible - Infectious - Recovered) model incorporating environmental factors. It was found that the absolute humidity was a dominant environmental factor. The study interpolated the humidity data monitored with 340 weather stations from 1951 to 2011 in mainland China. First, the break point of the trend for the absolutely humidity was detected by the BFAST (Break For Additive Season and Trend) method. Then, the SIR model with and without the absolutely humidity incorporated in the model was built and tested. Finally, the results with the two scenarios were compared. Results indicate that lower absolutely humidity may promote the transmission of the H1N1 cases. The calculated basic reproductive number ranges from 1.65 to 3.66 with a changing absolute humidity. This is consistent with the former study result with basic reproductive number ranging from 2.03 to 4.18. The average recovery duration was estimated to be 5.7 days. The average duration to get immunity from the influenza is 399.02 days. A risk map is also produced to illustrate the model results.
Pinhas, Alexander; Linderman, Rachel; Mo, Shelley; Krawitz, Brian D; Geyman, Lawrence S; Carroll, Joseph; Rosen, Richard B; Chui, Toco Y
2018-01-01
To present a method for age-matched deviation mapping in the assessment of disease-related changes to the radial peripapillary capillaries (RPCs). We reviewed 4.5x4.5mm en face peripapillary OCT-A scans of 133 healthy control eyes (133 subjects, mean 41.5 yrs, range 11-82 yrs) and 4 eyes with distinct retinal pathologies, obtained using spectral-domain optical coherence tomography angiography. Statistical analysis was performed to evaluate the impact of age on RPC perfusion densities. RPC density group mean and standard deviation maps were generated for each decade of life. Deviation maps were created for the diseased eyes based on these maps. Large peripapillary vessel (LPV; noncapillary vessel) perfusion density was also studied for impact of age. Average healthy RPC density was 42.5±1.47%. ANOVA and pairwise Tukey-Kramer tests showed that RPC density in the ≥60yr group was significantly lower compared to RPC density in all younger decades of life (p<0.01). Average healthy LPV density was 21.5±3.07%. Linear regression models indicated that LPV density decreased with age, however ANOVA and pairwise Tukey-Kramer tests did not reach statistical significance. Deviation mapping enabled us to quantitatively and visually elucidate the significance of RPC density changes in disease. It is important to consider changes that occur with aging when analyzing RPC and LPV density changes in disease. RPC density, coupled with age-matched deviation mapping techniques, represents a potentially clinically useful method in detecting changes to peripapillary perfusion in disease.
Vasak, Christoph; Watzak, Georg; Gahleitner, André; Strbac, Georg; Schemper, Michael; Zechner, Werner
2011-10-01
This prospective study was intended to evaluate the overall deviation in a clinical treatment setting to provide for quantification of the potential impairment of treatment safety and reliability with computer-assisted, template-guided transgingival implantation. The patient population enrolled (male/female=10/8) presented with partially dentate and edentulous maxillae and mandibles. Overall, 86 implants were placed by two experienced dental surgeons strictly following the NobelGuide™ protocol for template-guided implantation. All patients had a postoperative computed tomography (CT) with identical settings to the preoperative examination. Using the triple scan technique, pre- and postoperative CT data were merged in the Procera planning software, a newly developed procedure - initially presented in 2007 allowing measurement of the deviations at implant shoulder and apex. The deviations measured were an average of 0.43 mm (bucco-lingual), 0.46 mm (mesio-distal) and 0.53 mm (depth) at the level of the implant shoulder and slightly higher at the implant apex with an average of 0.7 mm (bucco-lingual), 0.63 mm (mesio-distal) and 0.52 mm (depth). The maximum deviation of 2.02 mm was encountered in the corono-apical direction. Significantly lower deviations were seen for implants in the anterior region vs. the posterior tooth region (P<0.01, 0.31 vs. 0.5 mm), and deviations were also significantly lower in the mandible than in the maxilla (P=0.04, 0.36 vs. 0.45 mm) in the mesio-distal direction. Moreover, a significant correlation between deviation and mucosal thickness was seen and a learning effect was found over the time period of performance of the surgical procedures. Template-guided implantation will ensure reliable transfer of preoperative computer-assisted planning into surgical practice. With regard to the required verification of treatment reliability of an implantation system with flapless access, all maximum deviations measured in this clinical study were within the safety margins recommended by the planning software. © 2011 John Wiley & Sons A/S.
CAD/CAM produces dentures with improved fit.
Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca
2018-02-22
Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.
Mayhew, S D; Mullinger, K J; Ostwald, D; Porcaro, C; Bowtell, R; Bagshaw, A P; Francis, S T
2016-06-01
In functional magnetic resonance imaging (fMRI), the relationship between positive BOLD responses (PBRs) and negative BOLD responses (NBRs) to stimulation is potentially informative about the balance of excitatory and inhibitory brain responses in sensory cortex. In this study, we performed three separate experiments delivering visual, motor or somatosensory stimulation unilaterally, to one side of the sensory field, to induce PBR and NBR in opposite brain hemispheres. We then assessed the relationship between the evoked amplitudes of contralateral PBR and ipsilateral NBR at the level of both single-trial and average responses. We measure single-trial PBR and NBR peak amplitudes from individual time-courses, and show that they were positively correlated in all experiments. In contrast, in the average response across trials the absolute magnitudes of both PBR and NBR increased with increasing stimulus intensity, resulting in a negative correlation between mean response amplitudes. Subsequent analysis showed that the amplitude of single-trial PBR was positively correlated with the BOLD response across all grey-matter voxels and was not specifically related to the ipsilateral sensory cortical response. We demonstrate that the global component of this single-trial response modulation could be fully explained by voxel-wise vascular reactivity, the BOLD signal standard deviation measured in a separate resting-state scan (resting state fluctuation amplitude, RSFA). However, bilateral positive correlation between PBR and NBR regions remained. We further report that modulations in the global brain fMRI signal cannot fully account for this positive PBR-NBR coupling and conclude that the local sensory network response reflects a combination of superimposed vascular and neuronal signals. More detailed quantification of physiological and noise contributions to the BOLD signal is required to fully understand the trial-by-trial PBR and NBR relationship compared with that of average responses. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald
2015-08-01
We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.
Historical Precision of an Ozone Correction Procedure for AM0 Solar Cell Calibration
NASA Technical Reports Server (NTRS)
Snyder, David B.; Jenkins, Phillip; Scheiman, David
2005-01-01
In an effort to improve the accuracy of the high altitude aircraft method for calibration of high band-gap solar cells, the ozone correction procedure has been revisited. The new procedure adjusts the measured short circuit current, Isc, according to satellite based ozone measurements and a model of the atmospheric ozone profile then extrapolates the measurements to air mass zero, AMO. The purpose of this paper is to assess the precision of the revised procedure by applying it to historical data sets. The average Isc of a silicon cell for a flying season increased 0.5% and the standard deviation improved from 0.5% to 0.3%. The 12 year average Isc of a GaAs cell increased 1% and the standard deviation improved from 0.8% to 0.5%. The slight increase in measured Isc and improvement in standard deviation suggests that the accuracy of the aircraft method may improve from 1% to nearly 0.5%.
Signal averaging limitations in heterodyne- and direct-detection laser remote sensing measurements
NASA Technical Reports Server (NTRS)
Menyuk, N.; Killinger, D. K.; Menyuk, C. R.
1983-01-01
The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.
Lin, Lawrence; Pan, Yi; Hedayat, A S; Barnhart, Huiman X; Haber, Michael
2016-01-01
Total deviation index (TDI) captures a prespecified quantile of the absolute deviation of paired observations from raters, observers, methods, assays, instruments, etc. We compare the performance of TDI using nonparametric quantile regression to the TDI assuming normality (Lin, 2000). This simulation study considers three distributions: normal, Poisson, and uniform at quantile levels of 0.8 and 0.9 for cases with and without contamination. Study endpoints include the bias of TDI estimates (compared with their respective theoretical values), standard error of TDI estimates (compared with their true simulated standard errors), and test size (compared with 0.05), and power. Nonparametric TDI using quantile regression, although it slightly underestimates and delivers slightly less power for data without contamination, works satisfactorily under all simulated cases even for moderate (say, ≥40) sample sizes. The performance of the TDI based on a quantile of 0.8 is in general superior to that of 0.9. The performances of nonparametric and parametric TDI methods are compared with a real data example. Nonparametric TDI can be very useful when the underlying distribution on the difference is not normal, especially when it has a heavy tail.
NASA Astrophysics Data System (ADS)
Krisna, Trismono C.; Wendisch, Manfred; Ehrlich, André; Jäkel, Evelyn; Werner, Frank; Weigel, Ralf; Borrmann, Stephan; Mahnke, Christoph; Pöschl, Ulrich; Andreae, Meinrat O.; Voigt, Christiane; Machado, Luiz A. T.
2018-04-01
Solar radiation reflected by cirrus and deep convective clouds (DCCs) was measured by the Spectral Modular Airborne Radiation Measurement System (SMART) installed on the German High Altitude and Long Range Research Aircraft (HALO) during the Mid-Latitude Cirrus (ML-CIRRUS) and the Aerosol, Cloud, Precipitation, and Radiation Interaction and Dynamic of Convective Clouds System - Cloud Processes of the Main Precipitation Systems in Brazil: A Contribution to Cloud Resolving Modelling and to the Global Precipitation Measurement (ACRIDICON-CHUVA) campaigns. On particular flights, HALO performed measurements closely collocated with overpasses of the Moderate Resolution Imaging Spectroradiometer (MODIS) aboard the Aqua satellite. A cirrus cloud located above liquid water clouds and a DCC topped by an anvil cirrus are analyzed in this paper. Based on the nadir spectral upward radiance measured above the two clouds, the optical thickness τ and particle effective radius reff of the cirrus and DCC are retrieved using a radiance ratio technique, which considers the cloud thermodynamic phase, the vertical profile of cloud microphysical properties, the presence of multilayer clouds, and the heterogeneity of the surface albedo. For the cirrus case, the comparison of τ and reff retrieved on the basis of SMART and MODIS measurements yields a normalized mean absolute deviation of up to 1.2 % for τ and 2.1 % for reff. For the DCC case, deviations of up to 3.6 % for τ and 6.2 % for reff are obtained. The larger deviations in the DCC case are mainly attributed to the fast cloud evolution and three-dimensional (3-D) radiative effects. Measurements of spectral upward radiance at near-infrared wavelengths are employed to investigate the vertical profile of reff in the cirrus. The retrieved values of reff are compared with corresponding in situ measurements using a vertical weighting method. Compared to the MODIS observations, measurements of SMART provide more information on the vertical distribution of particle sizes, which allow reconstructing the profile of reff close to the cloud top. The comparison between retrieved and in situ reff yields a normalized mean absolute deviation, which ranges between 1.5 and 10.3 %, and a robust correlation coefficient of 0.82.
The influence of cooling forearm/hand and gender on estimation of handgrip strength.
Cheng, Chih-Chan; Shih, Yuh-Chuan; Tsai, Yue-Jin; Chi, Chia-Fen
2014-01-01
Handgrip strength is essential in manual operations and activities of daily life, but the influence of forearm/hand skin temperature on estimation of handgrip strength is not well documented. Therefore, the present study intended to investigate the effect of local cooling of the forearm/hand on estimation of handgrip strength at various target force levels (TFLs, in percentage of MVC) for both genders. A cold pressor test was used to lower and maintain the hand skin temperature at 14°C for comparison with the uncooled condition. A total of 10 male and 10 female participants were recruited. The results indicated that females had greater absolute estimation deviations. In addition, both genders had greater absolute deviations in the middle range of TFLs. Cooling caused an underestimation of grip strength. Furthermore, a power function is recommended for establishing the relationship between actual and estimated handgrip force. Statement of relevance: Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the forearm/hand tended to cause underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Practitioner Summary: It is important to understand the effect of lowering the forearm/hand skin temperature on grip-strength estimation. A cold pressor was used to cool the hand. The cooling caused underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. Manipulation with grip strength is essential in daily life and the workplace, so it is important to understand the influence of lowering the forearm/hand skin temperature on grip-strength estimation. Females and the middle range of TFL had greater deviations. Cooling the forearm/hand tended to cause underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force. It is important to understand the effect of lowering the forearm/hand skin temperature on grip-strength estimation. A cold pressor was used to cool the hand. The cooling caused underestimation, and a power function is recommended for establishing the relationship between actual and estimated handgrip force
Stable fiber-optic time transfer by active radio frequency phase locking.
Yin, Feifei; Wu, Zhongle; Dai, Yitang; Ren, Tianpeng; Xu, Kun; Lin, Jintong; Tang, Geshi
2014-05-15
In this Letter we demonstrate a fiber link capable of stable time signal transfer utilizing our active long-distance radio frequency (RF) stabilization technology. Taking advantage of the chromatic dispersion in optical fiber, our scheme compensates dynamically the link delay variation by tuning the optical carrier wavelength to phase lock a round-trip RF reference. Since the time signal and the RF reference are carried by the same optical carrier, a highly stable time transfer is achieved at the same time. Experimentally, we demonstrate a stability of the time signal transfer over 50-km fiber with a time deviation of 40 ps at 1-s average and 2.3 ps at 1000-s average. The performance of the RF reference delivery is also tested, with an Allan deviation of 2×10(-15) at 1000-s average. According to our proposal, a simultaneous stable time and frequency transfer is expected.
Multi-Observation Continuous Density Hidden Markov Models for Anomaly Detection in Full Motion Video
2012-06-01
response profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 3.5 Method for measuring angular movement versus average direction...of movement 49 3.6 Method for calculating Angular Deviation, Θ . . . . . . . . . . . . . . . . . . 50 4.1 HMM produced by K Means Learning for agent H... Angular Deviation. A random variable, the difference in heading (in degrees) from the overall direction of movement over the sequence • S : Speed. A
42 CFR 486.318 - Condition: Outcome measures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... rate of eligible donors as a percentage of eligible deaths is no more than 1.5 standard deviations below the mean national donation rate of eligible donors as a percentage of eligible deaths, averaged...'s donation rate ratio are adjusted by adding a 1 for each donation after cardiac death donor and...
42 CFR 486.318 - Condition: Outcome measures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... rate of eligible donors as a percentage of eligible deaths is no more than 1.5 standard deviations below the mean national donation rate of eligible donors as a percentage of eligible deaths, averaged...'s donation rate ratio are adjusted by adding a 1 for each donation after cardiac death donor and...
42 CFR 486.318 - Condition: Outcome measures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... rate of eligible donors as a percentage of eligible deaths is no more than 1.5 standard deviations below the mean national donation rate of eligible donors as a percentage of eligible deaths, averaged...'s donation rate ratio are adjusted by adding a 1 for each donation after cardiac death donor and...
42 CFR 486.318 - Condition: Outcome measures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... rate of eligible donors as a percentage of eligible deaths is no more than 1.5 standard deviations below the mean national donation rate of eligible donors as a percentage of eligible deaths, averaged...'s donation rate ratio are adjusted by adding a 1 for each donation after cardiac death donor and...
NASA Astrophysics Data System (ADS)
Ye, Liming; Yang, Guixia; Van Ranst, Eric; Tang, Huajun
2013-03-01
A generalized, structural, time series modeling framework was developed to analyze the monthly records of absolute surface temperature, one of the most important environmental parameters, using a deterministicstochastic combined (DSC) approach. Although the development of the framework was based on the characterization of the variation patterns of a global dataset, the methodology could be applied to any monthly absolute temperature record. Deterministic processes were used to characterize the variation patterns of the global trend and the cyclic oscillations of the temperature signal, involving polynomial functions and the Fourier method, respectively, while stochastic processes were employed to account for any remaining patterns in the temperature signal, involving seasonal autoregressive integrated moving average (SARIMA) models. A prediction of the monthly global surface temperature during the second decade of the 21st century using the DSC model shows that the global temperature will likely continue to rise at twice the average rate of the past 150 years. The evaluation of prediction accuracy shows that DSC models perform systematically well against selected models of other authors, suggesting that DSC models, when coupled with other ecoenvironmental models, can be used as a supplemental tool for short-term (˜10-year) environmental planning and decision making.
APOLLO: a quality assessment service for single and multiple protein models.
Wang, Zheng; Eickholt, Jesse; Cheng, Jianlin
2011-06-15
We built a web server named APOLLO, which can evaluate the absolute global and local qualities of a single protein model using machine learning methods or the global and local qualities of a pool of models using a pair-wise comparison approach. Based on our evaluations on 107 CASP9 (Critical Assessment of Techniques for Protein Structure Prediction) targets, the predicted quality scores generated from our machine learning and pair-wise methods have an average per-target correlation of 0.671 and 0.917, respectively, with the true model quality scores. Based on our test on 92 CASP9 targets, our predicted absolute local qualities have an average difference of 2.60 Å with the actual distances to native structure. http://sysbio.rnet.missouri.edu/apollo/. Single and pair-wise global quality assessment software is also available at the site.
Patient satisfaction with correction of congenital penile curvature.
Mayer, M; Rey Valzacchi, G; Silva Garretón, A; Layus, O; Gueglio, G
2017-12-29
Congenital penile curvature is a relatively rare disease, resulting from a deviation of the penis from the body's straight axis when erect. The prevalence is difficult to determine. Although it has been suggested that the condition could affect up to 10% of the male population, most of these deviations are minor, with no clinical or psychological importance, which leads to its underdiagnosis. Effective correction of the deviation can markedly improve the quality of life of adolescents with this condition. To assess the quality of the sex life of patients diagnosed with congenital penile curvature who underwent surgical correction. Design Retrospective, observational cohort study. Data was collected from the medical records of patients who underwent surgical correction of congenital penile curvature from June 2004 to August 2016. The patients completed the following self-administered questionnaires: Sexual Quality of Life Questionnaire-Male (SQOL-M), International Index of Erectile Function 5 (IIEF 5) and "How satisfied are you with the results of the surgery? From 0 to 10". Twenty-two corporoplasties were performed to correct the patients' congenital penile curvature. The patients' average age was 23.4 years (range, 17-35). The mean deviation prior to surgery was 47.9° (range, 20°-90°). The average score on the SQOL-M was 52 points (range, 6-66). The average score on the IIEF 5 was 22.4 points. Congenital penile curvature profoundly decreases quality of life, and early surgery is fundamental for repairing the anatomical deformation and thereby significantly restores the patients' psychosocial and sexual wellbeing. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Fried, Terri R; Tinetti, Mary E; Towle, Virginia; O'Leary, John R; Iannone, Lynne
2011-05-23
Quality-assurance initiatives encourage adherence to evidenced-based guidelines based on a consideration of treatment benefit. We examined older persons' willingness to take medication for primary cardiovascular disease prevention according to benefits and harms. In-person interviews were performed with 356 community-living older persons. Participants were asked about their willingness to take medication for primary prevention of myocardial infarction (MI) with varying benefits in terms of absolute 5-year risk reduction and varying harms in terms of type and severity of adverse effects. Most (88%) would take medication, providing an absolute benefit of 6 fewer persons with MI out of 100, approximating the average risk reduction of currently available medications. Of participants who would not take it, 17% changed their preference if the absolute benefit was increased to 10 fewer persons with MI, and, of participants who would take it, 82% remained willing if the absolute benefit was decreased to 3 fewer persons with MI. In contrast, large proportions (48%-69%) were unwilling or uncertain about taking medication with average benefit causing mild fatigue, nausea, or fuzzy thinking, and only 3% would take medication with adverse effects severe enough to affect functioning. Older persons' willingness to take medication for primary cardiovascular disease prevention is relatively insensitive to its benefit but highly sensitive to its adverse effects. These results suggest that clinical guidelines and decisions about prescribing these medications to older persons need to place emphasis on both benefits and harms.
SNPP VIIRS RSB Earth View Reflectance Uncertainty
NASA Technical Reports Server (NTRS)
Lei, Ning; Twedt, Kevin; McIntire, Jeff; Xiong, Xiaoxiong
2017-01-01
The Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (SNPP) satellite uses its 14 reflective solar bands to passively collect solar radiant energy reflected off the Earth. The Level 1 product is the geolocated and radiometrically calibrated top-of- the-atmosphere solar reflectance. The absolute radiometric uncertainty associated with this product includes contributions from the noise associated with measured detector digital counts and the radiometric calibration bias. Here, we provide a detailed algorithm for calculating the estimated standard deviation of the retrieved top-of-the-atmosphere spectral solar radiation reflectance.
High-speed rangefinder for industrial application
NASA Astrophysics Data System (ADS)
Cavedo, Federico; Pesatori, Alessandro; Norgia, Michele
2016-06-01
The proposed work aims to improve one of the most used telemetry techniques to make absolute measurements of distance: the time of flight telemetry. The main limitation of the low-cost implementation of this technique is the low accuracy (some mm) and measurement rate (few measurements per second). In order to overcome these limits we modified the typical setup of this rangefinder exploiting low-cost telecommunication transceivers and radiofrequency synthesizers. The obtained performances are very encouraging, reaching a standard deviation of a few micrometers over the range of some meters.
Hyperfine-resolved transition frequency list of fundamental vibration bands of H35Cl and H37Cl
NASA Astrophysics Data System (ADS)
Iwakuni, Kana; Sera, Hideyuki; Abe, Masashi; Sasada, Hiroyuki
2014-12-01
Sub-Doppler resolution spectroscopy of the fundamental vibration bands of H35Cl and H37Cl has been carried out from 87.1 to 89.9 THz. We have determined the absolute transition frequencies of the hyperfine-resolved R(0) to R(4) transitions with a typical uncertainty of 10 kHz. We have also yielded six molecular constants for each isotopomer in the vibrational excited state, which reproduce the determined frequencies with a standard deviation of about 10 kHz.
Determination of carrier concentration and compensation microprofiles in GaAs
NASA Technical Reports Server (NTRS)
Jastrzebski, L.; Lagowski, J.; Walukiewicz, W.; Gatos, H. C.
1980-01-01
Simultaneous microprofiling of semiconductor free carrier, donor, and acceptor concentrations was achieved for the first time from the absolute value of the free carrier absorption coefficient and its wavelength dependence determined by IR absorption in a scanning mode. Employing Ge- and Si-doped melt-grown GaAs, striking differences were found between the variations of electron concentration and those of ionized impurity concentrations. These results showed clearly that the electronic characteristics of this material are controlled by amphoteric doping and deviations from stoichiometry rather than by impurity segregation.
High-Throughput RNA Interference Screening: Tricks of the Trade
Nebane, N. Miranda; Coric, Tatjana; Whig, Kanupriya; McKellip, Sara; Woods, LaKeisha; Sosa, Melinda; Sheppard, Russell; Rasmussen, Lynn; Bjornsti, Mary-Ann; White, E. Lucile
2016-01-01
The process of validating an assay for high-throughput screening (HTS) involves identifying sources of variability and developing procedures that minimize the variability at each step in the protocol. The goal is to produce a robust and reproducible assay with good metrics. In all good cell-based assays, this means coefficient of variation (CV) values of less than 10% and a signal window of fivefold or greater. HTS assays are usually evaluated using Z′ factor, which incorporates both standard deviation and signal window. A Z′ factor value of 0.5 or higher is acceptable for HTS. We used a standard HTS validation procedure in developing small interfering RNA (siRNA) screening technology at the HTS center at Southern Research. Initially, our assay performance was similar to published screens, with CV values greater than 10% and Z′ factor values of 0.51 ± 0.16 (average ± standard deviation). After optimizing the siRNA assay, we got CV values averaging 7.2% and a robust Z′ factor value of 0.78 ± 0.06 (average ± standard deviation). We present an overview of the problems encountered in developing this whole-genome siRNA screening program at Southern Research and how equipment optimization led to improved data quality. PMID:23616418
NASA Astrophysics Data System (ADS)
Evangelisti, Luca; Mayer, Kevin J.; Holdren, Martin S.; Smart, Taylor; West, Channing; Pate, Brooks; Sedo, Galen; Marshall, Frank E.; Grubbs, G. S., II
2017-06-01
Chiral analysis of a commercial sample of (1S)-(-)-verbenone has been performed using the chiral tag approach. The chirped-pulse Fourier transform microwave spectrum of the verbenone-butynol complex is measured in the 2-8 GHz frequency range. Verbenone is placed in a nozzle reservoir heated to 333K (about 1 Torr vapor pressure). The complex is formed by using a carrier gas of neon with approximately 0.1% butynol. The expansion pressure is about 2 atm. A measurement using racemic butynol is performed to identify isomers of both diastereomer complexes. Quantum chemistry calculations using the B3LYP-D3BJ method with the def2TZVP basis set provided estimated spectroscopic constants for the homochiral and heterochiral complexes. This analysis included 8 isomers for each diastereomer. Four rotational spectra are identified for isomers of the homochiral complex and correspond to the four lowest energy isomers from the theoretical study. Three heterochiral complexes are identified and also correspond to the lowest energy isomers from theory. Subsequent measurements were made with enantiopure tag (both (R)-(+)-3-buty-2-nol and (S)-(-)-3-butyn-2-ol) to establish the absolute configuration of verbenone. The sensitivity of the measurement was sufficient to perform ^{13}C-isotopologue analysis of three of the homochiral complexes and two of the heterochiral complexes. These results provide definitive structures of verbenone with correct stereochemistry. The commercial sample has relatively low enantiomeric excess with the certificate of analysis reporting an EE of 53.6%. Using the intensities of assigned transitions of the chiral tag complexes, the enantiomeric excess was determined from the broadband rotational spectrum through the ratio of the intensities of pairs of transitions. A total of 2617 pairs of transitions were analyzed. The average EE was found to be 53.6% with a standard deviation of 2%.
Responsiveness of a Brief Measure of Lung Cancer Screening Knowledge.
Housten, Ashley J; Lowenstein, Lisa M; Leal, Viola B; Volk, Robert J
2016-12-14
Our aim was to examine the responsiveness of a lung cancer screening brief knowledge measure (LCS-12). Eligible participants were aged 55-80 years, current smokers or had quit within 15 years, and English speaking. They completed a baseline pretest survey, viewed a lung cancer screening video-based patient decision aid, and then filled out a follow-up posttest survey. We performed a paired samples t-test, calculated effect size, and calculated absolute and relative percent improvement for each item. Participants (n = 30) were primarily White (63%) with less than a college degree (63%), and half were female (50%). Mean age was 61.5 years (standard deviation [SD] = 4.67) and average smoking history was 30.4 pack-years (range = 4.6-90.0). Mean score on the 12-item measure increased from 47.3% correct on the pretest to 80.3% correct on the posttest (mean pretest score = 5.67 vs. mean posttest score = 9.63; mean score difference = 3.97, SD = 2.87, 95% CI = 2.90, 5.04). Total knowledge scores improved significantly and were responsive to the decision aid intervention (paired samples t-test = 7.57, p < .001; Cohen's effect size = 1.59; standard response mean [SRM] = 1.38). All individual items were responsive, yet two items had lower absolute responsiveness than the others (item 8: "Without screening, is lung cancer often found at a later stage when cure is less likely?" pretest correct = 83.3% vs. posttest = 96.7%, responsiveness = 13.4%; and item 10: "Can a CT scan find lung disease that is not cancer?" pretest correct = 80.0% vs. posttest = 93.3%, responsiveness = 13.3%). The LCS-12 knowledge measure may be a useful outcome measure of shared decision making for lung cancer screening.
NASA Astrophysics Data System (ADS)
Buchholz, Bernhard; Afchine, Armin; Klein, Alexander; Schiller, Cornelius; Krämer, Martina; Ebert, Volker
2017-01-01
The novel Hygrometer for Atmospheric Investigation (HAI) realizes a unique concept for simultaneous gas-phase and total (gas-phase + evaporated cloud particles) water measurements. It has been developed and successfully deployed for the first time on the German HALO research aircraft. This new instrument combines direct tunable diode laser absorption spectroscopy (dTDLAS) with a first-principle evaluation method to allow absolute water vapor measurements without any initial or repetitive sensor calibration using a reference gas or a reference humidity generator. HAI contains two completely independent dual-channel (closed-path, open-path) spectrometers, one at 1.4 and one at 2.6 µm, which together allow us to cover the entire atmospheric H2O range from 1 to 40 000 ppmv with a single instrument. Both spectrometers each comprise a separate, wavelength-individual extractive, closed-path cell for total water (ice and gas-phase) measurements. Additionally, both spectrometers couple light into a common open-path cell outside of the aircraft fuselage for a direct, sampling-free, and contactless determination of the gas-phase water content. This novel twin dual-channel setup allows for the first time multiple self-validation functions, in particular a reliable, direct, in-flight validation of the open-path channels. During the first field campaigns, the in-flight deviations between the independent and calibration-free channels (i.e., closed-path to closed-path and open-path to closed-path) were on average in the 2 % range. Further, the fully autonomous HAI hygrometer allows measurements up to 240 Hz with a minimal integration time of 1.4 ms. The best precision is achieved by the 1.4 µm closed-path cell at 3.8 Hz (0.18 ppmv) and by the 2.6 µm closed-path cell at 13 Hz (0.055 ppmv). The requirements, design, operation principle, and first in-flight performance of the hygrometer are described and discussed in this work.
Identifying Stride-To-Stride Control Strategies in Human Treadmill Walking
Dingwell, Jonathan B.; Cusumano, Joseph P.
2015-01-01
Variability is ubiquitous in human movement, arising from internal and external noise, inherent biological redundancy, and from the neurophysiological control actions that help regulate movement fluctuations. Increased walking variability can lead to increased energetic cost and/or increased fall risk. Conversely, biological noise may be beneficial, even necessary, to enhance motor performance. Indeed, encouraging more variability actually facilitates greater improvements in some forms of locomotor rehabilitation. Thus, it is critical to identify the fundamental principles humans use to regulate stride-to-stride fluctuations in walking. This study sought to determine how humans regulate stride-to-stride fluctuations in stepping movements during treadmill walking. We developed computational models based on pre-defined goal functions to compare if subjects, from each stride to the next, tried to maintain the same speed as the treadmill, or instead stay in the same position on the treadmill. Both strategies predicted average behaviors empirically indistinguishable from each other and from that of humans. These strategies, however, predicted very different stride-to-stride fluctuation dynamics. Comparisons to experimental data showed that human stepping movements were generally well-predicted by the speed-control model, but not by the position-control model. Human subjects also exhibited no indications they corrected deviations in absolute position only intermittently: i.e., closer to the boundaries of the treadmill. Thus, humans clearly do not adopt a control strategy whose primary goal is to maintain some constant absolute position on the treadmill. Instead, humans appear to regulate their stepping movements in a way most consistent with a strategy whose primary goal is to try to maintain the same speed as the treadmill at each consecutive stride. These findings have important implications both for understanding how biological systems regulate walking in general and for being able to harness these mechanisms to develop more effective rehabilitation interventions to improve locomotor performance. PMID:25910253
Pandit, Jaideep J; Dexter, Franklin
2009-06-01
At multiple facilities including some in the United Kingdom's National Health Service, the following are features of many surgical-anesthetic teams: i) there is sufficient workload for each operating room (OR) list to almost always be fully scheduled; ii) the workdays are organized such that a single surgeon is assigned to each block of time (usually 8 h); iii) one team is assigned per block; and iv) hardly ever would a team "split" to do cases in more than one OR simultaneously. We used Monte-Carlo simulation using normal and Weibull distributions to estimate the times to complete lists of cases scheduled into such 8 h sessions. For each combination of mean and standard deviation, inefficiencies of use of OR time were determined for 10 h versus 8 h of staffing. When the mean actual hours of OR time used averages < or = 8 h 25 min, 8 h of staffing has higher OR efficiency than 10 h for all combinations of standard deviation and relative cost of over-run to under-run. When mean > or = 8 h 50 min, 10 h staffing has higher OR efficiency. For 8 h 25 min < mean < 8 h 50 min, the economic break-even point depends on conditions. For example, break-even is: (a) 8 h 27 min for Weibull, standard deviation of 60 min and relative cost of over-run to under-run of 2.0 versus (b) 8 h 48 min for normal, standard deviation of 0 min and relative cost ratio of 1.50. Although the simplest decision rule would be to staff for 8 h if the mean workload is < or = 8 h 40 min and to staff for 10 h otherwise, performance was poor. For example, for the Weibull distribution with mean 8 h 40 min, standard deviation 60 min, and relative cost ratio of 2.00, the inefficiency of use of OR time would be 34% larger if staffing were planned for 8 h instead of 10 h. For surgical teams with 8 h sessions, use the following decision rule for anesthesiology and OR nurse staffing. If actual hours of OR time used averages < or = 8 h 25 min, plan 8 h staffing. If average > or = 8 h 50 min, plan 10 h staffing. For averages in between, perform the full analysis of McIntosh et al. (Anesth Analg 2006;103:1499-516).
Mars-Gram Validation with Mars Global Surveyor Data
NASA Technical Reports Server (NTRS)
Justus, C. G.; Johnson, D.; Parker, Nelson C. (Technical Monitor)
2002-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many b4ars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model (MGCM), while above 80 km it is based on University of Arizona Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topography from Mars Global Surveyor Mars Orbiting Laser Altimeter (MOLA). Validation studies are described comparing Mars-GRAM with Mars Global Surveyor Radio Science (RS) and Thermal Emission Spectrometer (TES) data. RS data from 2480 profiles were used, covering latitudes 75deg S to 72deg N, surface to approx. 40 km, for seasons ranging from areocentric longitude of Sun (Ls) = 70-160deg and 265-310deg. RS data spanned a range of local times, mostly 0-9 hours and 18-24 hours. For interests in aerocapture and precision landing, comparisons concentrated on atmospheric density. At a fixed height of 20 km, measured RS density varied by about a factor of 2.5 over the range of latitudes and Ls values observed. Evaluated at matching positions and times, average RS/Mars-GRAM density ratios were generally lf0.05, except at heights above approx. 25 km and latitudes above approx.50deg N. Average standard deviation of RS/Mars-GRAM density ratio was 6%. TES data were used covering surface to approx. 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of Mars global dust storm). Depending on season, TES data covered latitudes 85deg S to 85deg N. Most TES data were concentrated near local times 2 hours and 14 hours. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (> 45deg N), or at most altitudes in the southern hemisphere at Ls approx. 90 and 180deg). Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approx. 6.5-10.5% (varying with height) for all data, or approx. 5- 12%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for 1o:al time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about the same as the standard deviation of TES data about the TES mean value at a given position and season.
Aerosol Measurements in the Mid-Atlantic: Trends and Uncertainty
NASA Astrophysics Data System (ADS)
Hains, J. C.; Chen, L. A.; Taubman, B. F.; Dickerson, R. R.
2006-05-01
Elevated levels of PM2.5 are associated with cardiovascular and respiratory problems and even increased mortality rates. In 2002 we ran two commonly used PM2.5 speciation samplers (an IMPROVE sampler and an EPA sampler) in parallel at Fort Meade, Maryland (a suburban site located in the Baltimore- Washington urban corridor). The filters were analyzed at different labs. This experiment allowed us to calculate the 'real world' uncertainties associated with these instruments. The EPA method retrieved a January average PM2.5 mass of 9.3 μg/m3 with a standard deviation of 2.8 μg/m3, while the IMPROVE method retrieved an average mass of 7.3 μg/m3 with a standard deviation of 2.1 μg/m3. The EPA method retrieved a July average PM2.5 mass of 26.4 μg/m3 with a standard deviation of 14.6 μg/m3, while the IMPROVE method retrieved an average mass of 23.3 μg/m3 with a standard deviation of 13.0 μg/m3. We calculated a 5% uncertainty associated with the EPA and IMPROVE methods that accounts for uncertainties in flow control strategies and laboratory analysis. The RMS difference between the two methods in January was 2.1 μg/m3, which is about 25% of the monthly average mass and greater than the uncertainty we calculated. In July the RMS difference between the two methods was 5.2 μg/m3, about 20% of the monthly average mass, and greater than the uncertainty we calculated. The EPA methods retrieve consistently higher concentrations of PM2.5 than the IMPROVE methods on a daily basis in January and July. This suggests a systematic bias possibly resulting from contamination of either of the sampling methods. We reconstructed the mass and found that both samplers have good correlation between reconstructed and gravimetric mass, though the IMPROVE method has slightly better correlation than the EPA method. In January, organic carbon is the largest contributor to PM2.5 mass, and in July both sulfate and organic matter contribute substantially to PM2.5. Source apportionment models suggest that regional and local power plants are the major sources of sulfate, while mobile and vegetative burning factors are the major sources of organic carbon.
Roelfs, David J.; Shor, Eran; Blank, Aharon; Schwartz, Joseph E.
2015-01-01
PURPOSE Individual-level unemployment has been consistently linked to poor health and higher mortality, but some scholars have suggested that the negative effect of job loss may be lower during times and in places where aggregate unemployment rates are high. We review three logics associated with this moderation hypothesis: health selection, social isolation, and unemployment stigma. We then test whether aggregate unemployment rates moderate the individual-level association between unemployment and all-cause mortality. METHODS We use 6 meta-regression models (each utilizing a different measure of the aggregate unemployment rate) based on 62 relative all-cause mortality risk estimates from 36 studies (from 15 nations). RESULTS We find that the magnitude of the individual-level unemployment-mortality association is approximately the same during periods of high and low aggregate-level unemployment. Model coefficients (exponentiated) were 1.01 for the crude unemployment rate (p = 0.27), 0.94 for the change in unemployment rate from the previous year (p = 0.46), 1.01 for the deviation of the unemployment rate from the 5-year running average (p = 0.87), 1.01 for the deviation of the unemployment rate from the 10-year running average (p = 0.73), 1.01 for the deviation of the unemployment rate from the overall average (measured as a continuous variable; p = 0.61), and showed no variation across unemployment levels when the deviation of the unemployment rate from the overall average was measured categorically. Heterogeneity between studies was significant (p < .001), supporting the use of the random effects model. CONCLUSIONS We found no strong evidence to suggest that unemployment experiences change when macro-economic conditions change. Efforts to ameliorate the negative social and economic consequences of unemployment should continue to focus on the individual and should be maintained regardless of periodic changes in macro-economic conditions. PMID:25795225
Roelfs, David J; Shor, Eran; Blank, Aharon; Schwartz, Joseph E
2015-05-01
Individual-level unemployment has been consistently linked to poor health and higher mortality, but some scholars have suggested that the negative effect of job loss may be lower during times and in places where aggregate unemployment rates are high. We review three logics associated with this moderation hypothesis: health selection, social isolation, and unemployment stigma. We then test whether aggregate unemployment rates moderate the individual-level association between unemployment and all-cause mortality. We use six meta-regression models (each using a different measure of the aggregate unemployment rate) based on 62 relative all-cause mortality risk estimates from 36 studies (from 15 nations). We find that the magnitude of the individual-level unemployment-mortality association is approximately the same during periods of high and low aggregate-level unemployment. Model coefficients (exponentiated) were 1.01 for the crude unemployment rate (P = .27), 0.94 for the change in unemployment rate from the previous year (P = .46), 1.01 for the deviation of the unemployment rate from the 5-year running average (P = .87), 1.01 for the deviation of the unemployment rate from the 10-year running average (P = .73), 1.01 for the deviation of the unemployment rate from the overall average (measured as a continuous variable; P = .61), and showed no variation across unemployment levels when the deviation of the unemployment rate from the overall average was measured categorically. Heterogeneity between studies was significant (P < .001), supporting the use of the random effects model. We found no strong evidence to suggest that unemployment experiences change when macroeconomic conditions change. Efforts to ameliorate the negative social and economic consequences of unemployment should continue to focus on the individual and should be maintained regardless of periodic changes in macroeconomic conditions. Copyright © 2015 Elsevier Inc. All rights reserved.
Investigating different computed tomography techniques for internal target volume definition.
Yoganathan, S A; Maria Das, K J; Subramanian, V Siva; Raj, D Gowtham; Agarwal, Arpita; Kumar, Shaleen
2017-01-01
The aim of this work was to evaluate the various computed tomography (CT) techniques such as fast CT, slow CT, breath-hold (BH) CT, full-fan cone beam CT (FF-CBCT), half-fan CBCT (HF-CBCT), and average CT for delineation of internal target volume (ITV). In addition, these ITVs were compared against four-dimensional CT (4DCT) ITVs. Three-dimensional target motion was simulated using dynamic thorax phantom with target insert of diameter 3 cm for ten respiration data. CT images were acquired using a commercially available multislice CT scanner, and the CBCT images were acquired using On-Board-Imager. Average CT was generated by averaging 10 phases of 4DCT. ITVs were delineated for each CT by contouring the volume of the target ball; 4DCT ITVs were generated by merging all 10 phases target volumes. Incase of BH-CT, ITV was derived by boolean of CT phases 0%, 50%, and fast CT target volumes. ITVs determined by all CT and CBCT scans were significantly smaller (P < 0.05) than the 4DCT ITV, whereas there was no significant difference between average CT and 4DCT ITVs (P = 0.17). Fast CT had the maximum deviation (-46.1% ± 20.9%) followed by slow CT (-34.3% ± 11.0%) and FF-CBCT scans (-26.3% ± 8.7%). However, HF-CBCT scans (-12.9% ± 4.4%) and BH-CT scans (-11.1% ± 8.5%) resulted in almost similar deviation. On the contrary, average CT had the least deviation (-4.7% ± 9.8%). When comparing with 4DCT, all the CT techniques underestimated ITV. In the absence of 4DCT, the HF-CBCT target volumes with appropriate margin may be a reasonable approach for defining the ITV.
NASA Technical Reports Server (NTRS)
Meneghini, Robert; Kim, Hyokyung
2016-01-01
For an airborne or spaceborne radar, the precipitation-induced path attenuation can be estimated from the measurements of the normalized surface cross section, sigma 0, in the presence and absence of precipitation. In one implementation, the mean rain-free estimate and its variability are found from a lookup table (LUT) derived from previously measured data. For the dual-frequency precipitation radar aboard the global precipitation measurement satellite, the nominal table consists of the statistics of the rain-free 0 over a 0.5 deg x 0.5 deg latitude-longitude grid using a three-month set of input data. However, a problem with the LUT is an insufficient number of samples in many cells. An alternative table is constructed by a stepwise procedure that begins with the statistics over a 0.25 deg x 0.25 deg grid. If the number of samples at a cell is too few, the area is expanded, cell by cell, choosing at each step that cell that minimizes the variance of the data. The question arises, however, as to whether the selected region corresponds to the smallest variance. To address this question, a second type of variable-averaging grid is constructed using all possible spatial configurations and computing the variance of the data within each region. Comparisons of the standard deviations for the fixed and variable-averaged grids are given as a function of incidence angle and surface type using a three-month set of data. The advantage of variable spatial averaging is that the average standard deviation can be reduced relative to the fixed grid while satisfying the minimum sample requirement.
Importance of the levator labii alaeque nasi muscle in dorsal septal deviations.
Tellioğlu, Ali Teoman; Özakpinar, Hülda Rifat; Cakir, Bariş; Tekdemir, Ibrahim
2011-03-01
Deviated cartilages structures of the nose can be affected by nasal muscles, and deviation becomes conspicuous when the patient smiles. This condition depends on activity of nasal muscles, particularly the levator labii alaeque nasi muscle. A total of 124 septorhinoplasty operations were performed to correct dorsal concave septal deviation between 2005 and 2009 years. The 70 women and 54 men included in the study had an average age of 28 years. The average follow-up period was 12 months. Open septorhinoplasty was preferred in all cases. The medial part of the levator labii alaeque nasi muscle was extensively dissected from the lateral crus and surrounding tissues. The lateral crura of the alar cartilages were separated from the upper lateral cartilages in the scroll area. The dorsal septal deviation was corrected by combination of bilateral spreader grafts, which reinforced cartilage with horizontal control sutures. Early postoperative period was uneventful. Nasal obstruction was reduced after surgery, and significant subjective postoperative improvements were observed in all patients. Comparison of preoperative and postoperative photographs demonstrated improved dorsal nasal contour. Revision operation was performed in 3 cases. The corrected septal cartilage was in a good position in all revised cases; therefore, septal surgery was not performed in the revision operations. In conclusion, surgical disruption of the anatomic relationship between the muscle with the dorsal septal cartilage and reinforcement of the dorsal septal cartilage with spreader grafts and horizontal control sutures can decrease risk of recurrence.
Toddle temporal-spatial deviation index: Assessment of pediatric gait.
Cahill-Rowley, Katelyn; Rose, Jessica
2016-09-01
This research aims to develop a gait index for use in the pediatric clinic as well as research, that quantifies gait deviation in 18-22 month-old children: the Toddle Temporal-spatial Deviation Index (Toddle TDI). 81 preterm children (≤32 weeks) with very-low-birth-weights (≤1500g) and 42 full-term TD children aged 18-22 months, adjusted for prematurity, walked on a pressure-sensitive mat. Preterm children were administered the Bayley Scales of Infant Development-3rd Edition (BSID-III). Principle component analysis of TD children's temporal-spatial gait parameters quantified raw gait deviation from typical, normalized to an average(standard deviation) Toddle TDI score of 100(10), and calculated for all participants. The Toddle TDI was significantly lower for preterm versus TD children (86 vs. 100, p=0.003), and lower in preterm children with <85 vs. ≥85 BSID-III motor composite scores (66 vs. 89, p=0.004). The Toddle TDI, which by design plateaus at typical average (BSID-III gross motor 8-12), correlated with BSID-III gross motor (r=0.60, p<0.001) and not fine motor (r=0.08, p=0.65) in preterm children with gross motor scores ≤8, suggesting sensitivity to gross motor development. The Toddle TDI demonstrated sensitivity and specificity to gross motor function in very-low-birth-weight preterm children aged 18-22 months, and has been potential as an easily-administered, revealing clinical gait metric. Copyright © 2016 Elsevier B.V. All rights reserved.
Winkler, Robert
2010-02-01
Electrospray ionization (ESI) ion trap mass spectrometers with relatively low resolution are frequently used for the analysis of natural products and peptides. Although ESI spectra of multiply charged protein molecules also can be measured on this type of devices, only average spectra are produced for the majority of naturally occurring proteins. Evaluating such ESI protein spectra would provide valuable information about the native state of investigated proteins. However, no suitable and freely available software could be found which allows the charge state determination and molecular weight calculation of single proteins from average ESI-MS data. Therefore, an algorithm based on standard deviation optimization (scatter minimization) was implemented for the analysis of protein ESI-MS data. The resulting software ESIprot was tested with ESI-MS data of six intact reference proteins between 12.4 and 66.7 kDa. In all cases, the correct charge states could be determined. The obtained absolute mass errors were in a range between -0.2 and 1.2 Da, the relative errors below 30 ppm. The possible mass accuracy allows for valid conclusions about the actual condition of proteins. Moreover, the ESIprot algorithm demonstrates an extraordinary robustness and allows spectral interpretation from as little as two peaks, given sufficient quality of the provided m/z data, without the necessity for peak intensity data. ESIprot is independent from the raw data format and the computer platform, making it a versatile tool for mass spectrometrists. The program code was released under the open-source GPLv3 license to support future developments of mass spectrometry software. Copyright 2010 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y; Giebeler, A; Mascia, A
Purpose: To quantitatively evaluate dosimetric consequence of spot size variations and validate beam-matching criteria for commissioning a pencil beam model for multiple treatment rooms. Methods: A planning study was first conducted by simulating spot size variations to systematically evaluate dosimetric impact of spot size variations in selected cases, which was used to establish the in-air spot size tolerance for beam matching specifications. A beam model in treatment planning system was created using in-air spot profiles acquired in one treatment room. These spot profiles were also acquired from another treatment room for assessing the actual spot size variations between the twomore » treatment rooms. We created twenty five test plans with targets of different sizes at different depths, and performed dose measurement along the entrance, proximal and distal target regions. The absolute doses at those locations were measured using ionization chambers at both treatment rooms, and were compared against the calculated doses by the beam model. Fifteen additional patient plans were also measured and included in our validation. Results: The beam model is relatively insensitive to spot size variations. With an average of less than 15% measured in-air spot size variations between two treatment rooms, the average dose difference was −0.15% with a standard deviation of 0.40% for 55 measurement points within target region; but the differences increased to 1.4%±1.1% in the entrance regions, which are more affected by in-air spot size variations. Overall, our single-room based beam model in the treatment planning system agreed with measurements in both rooms < 0.5% within the target region. For fifteen patient cases, the agreement was within 1%. Conclusion: We have demonstrated that dosimetrically equivalent machines can be established when in-air spot size variations are within 15% between the two treatment rooms.« less
Density functional study of double ionization energies
NASA Astrophysics Data System (ADS)
Chong, D. P.
2008-02-01
In this paper, double ionization energies (DIEs) of gas-phase atoms and molecules are calculated by energy difference method with density functional theory. To determine the best functional for double ionization energies, we first study 24 main group atoms in the second, third, and fourth periods. An approximation is used in which the electron density is first obtained from a density functional computation with the exchange-correlation potential Vxc known as statistical average of orbital potentials, after which the energy is computed from that density with 59 different exchange-correlation energy functionals Exc. For the 24 atoms, the two best Exc functional providing DIEs with average absolute deviation (AAD) of only 0.25eV are the Perdew-Burke-Ernzerhof functional modified by Hammer et al. [Phys. Rev. B 59, 6413 (1999)] and one known as the Krieger-Chen-Iafrate-Savin functional modified by Krieger et al. (unpublished). Surprisingly, none of the 20 available hybrid functionals is among the top 15 functionals for the DIEs of the 24 atoms. A similar procedure is then applied to molecules, with opposite results: Only hybrid functionals are among the top 15 functionals for a selection of 29molecules. The best Exc functional for the 29molecules is found to be the Becke 1997 functional modified by Wilson et al. [J. Chem. Phys. 115, 9233 (2001)]. With that functional, the AAD from experiment for DIEs of 29molecules is just under 0.5eV. If the two suspected values for C2H2 and Fe(CO)5 are excluded, the AAD improves to 0.32eV. Many other hybrid functionals perform almost as well.
Rebellato, Andrea; Grillo, Andrea; Dassie, Francesca; Sonino, Nicoletta; Maffei, Pietro; Martini, Chiara; Paoletta, Agostino; Fabris, Bruno; Carretta, Renzo; Fallo, Francesco
2014-11-01
Cushing's syndrome is associated with high cardiovascular morbility and mortality. Blood pressure (BP) variability within a 24-h period is increasingly recognized as an independent predictor of cardiovascular risk. The aim of our study was to investigate the short-term BP variability indices in Cushing's syndrome. Twenty-five patients with Cushing's syndrome (mean age 49 ± 13 years, 4 males; 21 Cushing's disease and 4 adrenal adenoma patients) underwent 24-h ambulatory BP monitoring (ABPM) and evaluation of cardiovascular risk factors. Cushing patients were divided into 8 normotensive (NOR-CUSH) and 17 hypertensive (HYP-CUSH) patients and were compared with 20 normotensive (NOR-CTR) and 20 hypertensive (HYP-CTR) age-, sex-, and BMI-matched control subjects. Short-term BP variability was derived from ABPM and calculated as the following: (1) standard deviation (SD) of 24-h, daytime, and nighttime BP; (2) 24-h weighted SD of BP; and (3) average real variability (ARV), i.e., the average of the absolute differences between consecutive BP measurements over 24 h. In comparison with controls, patients with Cushing's syndrome, either normotensive or hypertensive, had higher 24-h and daytime SD of BP, as well as higher 24-h weighted SD and ARV of BP (P = 0.03 to P < 0.0001). No difference in metabolic parameters was observed between NOR-CTR and NOR-CUSH or between HYP-CTR and HYP-CUSH subgroups. ABPM-derived short-term BP variability is increased in Cushing's syndrome, independent of BP elevation. It may represent an additional cardiovascular risk factor in this disease. The role of excess cortisol in BP variability has to be further clarified.
Vinod, Shalini K; Lim, Karen; Bell, Lauren; Veera, Jacqueline; Ohanessian, Lucy; Juresic, Ewa; Borok, Nira; Chan, Phillip; Chee, Raphael; Do, Viet; Govindarajulu, Geetha; Sridharan, Swetha; Johnson, Carol; Moses, Daniel; Van Dyk, Sylvia; Holloway, Lois
2017-02-01
Image-based brachytherapy for cervical cancer using MRI has been implemented in Australia and New Zealand. The aims of this study were to measure variability in High-risk CTV (HR-CTV) delineation and evaluate dosimetric consequences of this. Nine radiation oncologists, one radiation therapist and two radiologists contoured HR-CTV on 3T MRI datasets from ten consecutive patients undergoing cervical brachytherapy at a single institution. Contour comparisons were performed using the Dice Similarity Coefficient (DSC) and Mean Absolute Surface Distance (MASD). Two reference contours were created for brachytherapy planning: a Simultaneous Truth and Performance Level Estimation (STAPLE) and a consensus contour (CONSENSUS). Optimized plans (8 Gy) for both these contours were applied to individual participant's contours to assess D90 and D100 coverage of HR CTV. To compare variability in dosimetry, relative standard deviation (rSD) was calculated. Good concordance (mean DSC≥0.7, MASD≤5 mm) was achieved in 8/10 cases when compared to the STAPLE reference and 6/10 cases when compared to the CONSENSUS reference. Greatest variation was visually seen in the cranio-caudal direction. The average mean rSD across all patients was 27% and 34% for the STAPLE HR-CTV D90 and D100, respectively, and 28% and 35% for the CONSENSUS HR-CTV D90 and D100. Delineation uncertainty resulted in an average dosimetric uncertainty of ±1.5-1.6 Gy per fraction based on an 8 Gy prescribed fraction. Delineation of HR-CTV for cervical cancer brachytherapy was consistent amongst observers, suggesting similar interpretation of GEC-ESTRO guidelines. Despite the good concordance, there was dosimetric variation noted, which could be clinically significant. © 2016 The Royal Australian and New Zealand College of Radiologists.
NASA Astrophysics Data System (ADS)
Yang, Yong; Li, Chengshan
2017-10-01
The effect of minor loop size on the magnetic stiffness has not been paid attention to by most researchers in experimental and theoretical studies about the high temperature superconductor (HTS) magnetic levitation system. In this work, we numerically investigate the average magnetic stiffness obtained by the minor loop traverses Δz (or Δx) varying from 0.1 mm to 2 mm in zero field cooling and field cooling regimes, respectively. The approximate values of the magnetic stiffness with zero traverse are obtained using the method of linear extrapolation. Compared with the average magnetic stiffness gained by any minor loop traverse, these approximate values are Not always close to the average magnetic stiffness produced by the smallest size of minor loops. The relative deviation ranges of average magnetic stiffness gained by the usually minor loop traverse (1 or 2 mm) are presented by the ratios of approximate values to average stiffness for different moving processes and two typical cooling conditions. The results show that most of average magnetic stiffness are remarkably influenced by the sizes of minor loop, which indicates that the magnetic stiffness obtained by a single minor loop traverse Δ z or Δ x, for example, 1 or 2 mm, can be generally caused a large deviation.
Full-Field Calibration of Color Camera Chromatic Aberration using Absolute Phase Maps.
Liu, Xiaohong; Huang, Shujun; Zhang, Zonghua; Gao, Feng; Jiang, Xiangqian
2017-05-06
The refractive index of a lens varies for different wavelengths of light, and thus the same incident light with different wavelengths has different outgoing light. This characteristic of lenses causes images captured by a color camera to display chromatic aberration (CA), which seriously reduces image quality. Based on an analysis of the distribution of CA, a full-field calibration method based on absolute phase maps is proposed in this paper. Red, green, and blue closed sinusoidal fringe patterns are generated, consecutively displayed on an LCD (liquid crystal display), and captured by a color camera from the front viewpoint. The phase information of each color fringe is obtained using a four-step phase-shifting algorithm and optimum fringe number selection method. CA causes the unwrapped phase of the three channels to differ. These pixel deviations can be computed by comparing the unwrapped phase data of the red, blue, and green channels in polar coordinates. CA calibration is accomplished in Cartesian coordinates. The systematic errors introduced by the LCD are analyzed and corrected. Simulated results show the validity of the proposed method and experimental results demonstrate that the proposed full-field calibration method based on absolute phase maps will be useful for practical software-based CA calibration.
NASA Astrophysics Data System (ADS)
Francis, Olivier; Baumann, Henri; Volarik, Tomas; Rothleitner, Christian; Klein, Gilbert; Seil, Marc; Dando, Nicolas; Tracey, Ray; Ullrich, Christian; Castelein, Stefaan; Hua, Hu; Kang, Wu; Chongyang, Shen; Songbo, Xuan; Hongbo, Tan; Zhengyuan, Li; Pálinkás, Vojtech; Kostelecký, Jakub; Mäkinen, Jaakko; Näränen, Jyri; Merlet, Sébastien; Farah, Tristan; Guerlin, Christine; Pereira Dos Santos, Franck; Le Moigne, Nicolas; Champollion, Cédric; Deville, Sabrina; Timmen, Ludger; Falk, Reinhard; Wilmes, Herbert; Iacovone, Domenico; Baccaro, Francesco; Germak, Alessandro; Biolcati, Emanuele; Krynski, Jan; Sekowski, Marcin; Olszak, Tomasz; Pachuta, Andrzej; Agren, Jonas; Engfeldt, Andreas; Reudink, René; Inacio, Pedro; McLaughlin, Daniel; Shannon, Geoff; Eckl, Marc; Wilkins, Tim; van Westrum, Derek; Billson, Ryan
2013-06-01
We present the results of the third European Comparison of Absolute Gravimeters held in Walferdange, Grand Duchy of Luxembourg, in November 2011. Twenty-two gravimeters from both metrological and non-metrological institutes are compared. For the first time, corrections for the laser beam diffraction and the self-attraction of the gravimeters are implemented. The gravity observations are also corrected for geophysical gravity changes that occurred during the comparison using the observations of a superconducting gravimeter. We show that these corrections improve the degree of equivalence between the gravimeters. We present the results for two different combinations of data. In the first one, we use only the observations from the metrological institutes. In the second solution, we include all the data from both metrological and non-metrological institutes. Those solutions are then compared with the official result of the comparison published previously and based on the observations of the metrological institutes and the gravity differences at the different sites as measured by non-metrological institutes. Overall, the absolute gravity meters agree with one another with a standard deviation of 3.1 µGal. Finally, the results of this comparison are linked to previous ones. We conclude with some important recommendations for future comparisons.
Family structure and childhood anthropometry in Saint Paul, Minnesota in 1918
Warren, John Robert
2017-01-01
Concern with childhood nutrition prompted numerous surveys of children’s growth in the United States after 1870. The Children’s Bureau’s 1918 “Weighing and Measuring Test” measured two million children to produce the first official American growth norms. Individual data for 14,000 children survives from the Saint Paul, Minnesota survey whose stature closely approximated national norms. As well as anthropometry the survey recorded exact ages, street address and full name. These variables allow linkage to the 1920 census to obtain demographic and socioeconomic information. We matched 72% of children to census families creating a sample of nearly 10,000 children. Children in the entire survey (linked set) averaged 0.74 (0.72) standard deviations below modern WHO height-for-age standards, and 0.48 (0.46) standard deviations below modern weight-for-age norms. Sibship size strongly influenced height-for-age, and had weaker influence on weight-for-age. Each additional child six or underreduced height-for-age scores by 0.07 standard deviations (95% CI: −0.03, 0.11). Teenage siblings had little effect on height-forage. Social class effects were substantial. Children of laborers averaged half a standard deviation shorter than children of professionals. Family structure and socio-economic status had compounding impacts on children’s stature. PMID:28943749
[Navigation in implantology: Accuracy assessment regarding the literature].
Barrak, Ibrahim Ádám; Varga, Endre; Piffko, József
2016-06-01
Our objective was to assess the literature regarding the accuracy of the different static guided systems. After applying electronic literature search we found 661 articles. After reviewing 139 articles, the authors chose 52 articles for full-text evaluation. 24 studies involved accuracy measurements. Fourteen of our selected references were clinical and ten of them were in vitro (modell or cadaver). Variance-analysis (Tukey's post-hoc test; p < 0.05) was conducted to summarize the selected publications. Regarding 2819 results the average mean error at the entry point was 0.98 mm. At the level of the apex the average deviation was 1.29 mm while the mean of the angular deviation was 3,96 degrees. Significant difference could be observed between the two methods of implant placement (partially and fully guided sequence) in terms of deviation at the entry point, apex and angular deviation. Different levels of quality and quantity of evidence were available for assessing the accuracy of the different computer-assisted implant placement. The rapidly evolving field of digital dentistry and the new developments will further improve the accuracy of guided implant placement. In the interest of being able to draw dependable conclusions and for the further evaluation of the parameters used for accuracy measurements, randomized, controlled single or multi-centered clinical trials are necessary.
[Reproductive biology and artificial propagation of Acipenser sinensis below Gezhouba Dam].
Liu, Jian-yi; Wei, Qi-wei; Chen, Xi-hua; Yang, De-guo; Du, Hao; Zhu, Yong-jiu
2007-06-01
A total of 36 females and 21 males of Chinese sturgeon Acipenser sinensis were caught in 1998-2004 excluding 2002 to study the characteristics of their reproductive biology and the effect of their artificial propagation. The results showed that the body length (BL), body mass (BM) and age of the females were 240-320 cm, 140-432 kg, and 15-30 years, and those of the males were 153-284 cm, 70-244 kg and 12-26 years, respectively. The inducing rate was 93.1% for females and 100% for males, and the ova had 7 different colors. The absolute fecundity was 200,000-590,000 eggs, with an average of 358,000 eggs, and the relative fecundity to BM was 820-3,020 eggs per kg, with an average of 1,590 eggs per kg. The sperm had 4 different colors. The absolute sperm quantity obtained from one male was 1,000-5,952 ml, with an average of 2,597.8 ml, and the relative sperm quantity to BM was 1.25-31.24 ml . kg(-1), with an average of 13.3 ml . kg(-1). During the study period, the average fertilization rate in artificial propagation was 63.7%, and the hatching rate was 48.1%, with 4,762,000 fry obtained. Compared with the data in 1976, the natural reproductive capacity of the Chinese sturgeon broodstocks declined greatly.
42 CFR 486.318 - Condition: Outcome measures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... donation rate of eligible donors as a percentage of eligible deaths is no more than 1.5 standard deviations below the mean national donation rate of eligible donors as a percentage of eligible deaths, averaged...'s donation rate ratio are adjusted by adding a 1 for each donation after cardiac death donor and...
Demand forecasting of electricity in Indonesia with limited historical data
NASA Astrophysics Data System (ADS)
Dwi Kartikasari, Mujiati; Rohmad Prayogi, Arif
2018-03-01
Demand forecasting of electricity is an important activity for electrical agents to know the description of electricity demand in future. Prediction of demand electricity can be done using time series models. In this paper, double moving average model, Holt’s exponential smoothing model, and grey model GM(1,1) are used to predict electricity demand in Indonesia under the condition of limited historical data. The result shows that grey model GM(1,1) has the smallest value of MAE (mean absolute error), MSE (mean squared error), and MAPE (mean absolute percentage error).
Energy dispersive X-ray analysis on an absolute scale in scanning transmission electron microscopy.
Chen, Z; D'Alfonso, A J; Weyland, M; Taplin, D J; Allen, L J; Findlay, S D
2015-10-01
We demonstrate absolute scale agreement between the number of X-ray counts in energy dispersive X-ray spectroscopy using an atomic-scale coherent electron probe and first-principles simulations. Scan-averaged spectra were collected across a range of thicknesses with precisely determined and controlled microscope parameters. Ionization cross-sections were calculated using the quantum excitation of phonons model, incorporating dynamical (multiple) electron scattering, which is seen to be important even for very thin specimens. Copyright © 2015 Elsevier B.V. All rights reserved.
Non-Contact Determination of Antisymmetric Plate Wave Velocity in Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Kautz, Harold E.
1996-01-01
A 13 mJ NdYAG 1064 nm, 4 ns, laser pulse was employed to produce ultrasonic plate waves in 20 percent porous SiC/SiC composite tensile specimens of three different architectures. An air coupled 0.5 MHz transducer was used to detect and collect the waveforms which contained first antisymmetric plate wave pulses for determining the shear wave velocity (VS). These results were compared to VS values determined on the same specimens with 0.5 MHz ultrasonic transducers with contact coupling. Averages of four noncontact determinations on each of 18 specimens were compared to averages of four contact values. The noncontact VS's fall in the same range as the contact. The standard deviations for the noncontact VS's averaged 2.8 percent. The standard deviations for the contact measurements averaged 2.3 percent, indicating similar reproducibility. Repeated laser pulsing at the same location always lead to deterioration of the ulu-"nic signal. The signal would recover in about 24 hr in air however, indicating that no permanent damage was produced.
Stability Analysis of Receiver ISB for BDS/GPS
NASA Astrophysics Data System (ADS)
Zhang, H.; Hao, J. M.; Tian, Y. G.; Yu, H. L.; Zhou, Y. L.
2017-07-01
Stability analysis of receiver ISB (Inter-System Bias) is essential for understanding the feature of ISB as well as the ISB modeling and prediction. In order to analyze the long-term stability of ISB, the data from MGEX (Multi-GNSS Experiment) covering 3 weeks, which are from 2014, 2015 and 2016 respectively, are processed with the precise satellite clock and orbit products provided by Wuhan University and GeoForschungsZentrum (GFZ). Using the ISB calculated by BDS (BeiDou Navigation Satellite System)/GPS (Global Positioning System) combined PPP (Precise Point Positioning), the daily stability and weekly stability of ISB are investigated. The experimental results show that the diurnal variation of ISB is stable, and the average of daily standard deviation is about 0.5 ns. The weekly averages and standard deviations of ISB vary greatly in different years. The weekly averages of ISB are relevant to receiver types. There is a system bias between ISB calculated from the precise products provided by Wuhan University and GFZ. In addition, the system bias of the weekly average ISB of different stations is consistent with each other.
Accounting for body size deviations when reporting bone mineral density variables in children.
Webber, C E; Sala, A; Barr, R D
2009-01-01
In a child, bone mineral density (BMD) may differ from an age-expected normal value, not only because of the presence of disease, but also because of deviations of height or weight from population averages. Appropriate adjustment for body size deviations simplifies interpretation of BMD measurements. For children, a bone mineral density (BMD) measurement is normally expressed as a Z score. Interpretation is complicated when weight or height distinctly differ from age-matched children. We develop a procedure to allow for the influence of body size deviations upon measured BMD. We examined the relation between body size deviation and spine, hip and whole body BMD deviation in 179 normal children (91 girls). Expressions were developed that allowed derivation of an expected BMD based on age, gender and body size deviation. The difference between measured and expected BMD was expressed as a HAW score (Height-, Age-, Weight-adjusted score). In a second independent sample of 26 normal children (14 girls), measured spine, total femur and whole body BMD all fell within the same single normal range after accounting for age, gender and body size deviations. When traditional Z scores and HAW scores were compared in 154 children, 17.5% showed differences of more than 1 unit and such differences were associated with height and weight deviations. For almost 1 in 5 children, body size deviations influence BMD to an extent that could alter clinical management.
Zero absolute vorticity: insight from experiments in rotating laminar plane Couette flow.
Suryadi, Alexandre; Segalini, Antonio; Alfredsson, P Henrik
2014-03-01
For pressure-driven turbulent channel flows undergoing spanwise system rotation, it has been observed that the absolute vorticity, i.e., the sum of the averaged spanwise flow vorticity and system rotation, tends to zero in the central region of the channel. This observation has so far eluded a convincing theoretical explanation, despite experimental and numerical evidence reported in the literature. Here we show experimentally that three-dimensional laminar structures in plane Couette flow, which appear under anticyclonic system rotation, give the same effect, namely, that the absolute vorticity tends to zero if the rotation rate is high enough. It is shown that this is equivalent to a local Richardson number of approximately zero, which would indicate a stable condition. We also offer an explanation based on Kelvin's circulation theorem to demonstrate that the absolute vorticity should remain constant and approximately equal to zero in the central region of the channel when going from the nonrotating fully turbulent state to any state with sufficiently high rotation.
On Deviations between Observed and Theoretically Estimated Values on Additivity-Law Failures
NASA Astrophysics Data System (ADS)
Nayatani, Yoshinobu; Sobagaki, Hiroaki
The authors have reported in the previous studies that the average observed results are about a half of the corresponding predictions on the experiments with large additivity-law failures. One of the reasons of the deviations is studied and clarified by using the original observed data on additivity-law failures in the Nakano experiment. The conclusion from the observations and their analyses clarified that it was essentially difficult to have a good agreement between the average observed results and the corresponding theoretical predictions in the experiments with large additivity-law failures. This is caused by a kind of unavoidable psychological pressure existing in subjects participated in the experiments. We should be satisfied with the agreement in trend between them.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, X.; Senftleben, A.; Pflueger, T.
Absolutely normalized (e,2e) measurements for H{sub 2} and He covering the full solid angle of one ejected electron are presented for 16 eV sum energy of both final state continuum electrons. For both targets rich cross-section structures in addition to the binary and recoil lobes are identified and studied as a function of the fixed electron's emission angle and the energy sharing among both electrons. For H{sub 2} their behavior is consistent with multiple scattering of the projectile as discussed before [Al-Hagan et al., Nature Phys. 5, 59 (2009)]. For He the binary and recoil lobes are significantly larger thanmore » for H{sub 2} and partly cover the multiple scattering structures. To highlight these patterns we propose a alternative representation of the triply differential cross section. Nonperturbative calculations are in good agreement with the He results and show discrepancies for H{sub 2} in the recoil peak region. For H{sub 2} a perturbative approach reasonably reproduces the cross-section shape but deviates in absolute magnitude.« less
Yang, Lijun; Wu, Xuejian; Wei, Haoyun; Li, Yan
2017-04-10
The absolute group refractive index of air at 194061.02 GHz is measured in real time using frequency-sweeping interferometry calibrated by an optical frequency comb. The group refractive index of air is calculated from the calibration peaks of the laser frequency variation and the interference signal of the two beams passing through the inner and outer regions of a vacuum cell when the frequency of a tunable external cavity diode laser is scanned. We continuously measure the refractive index of air for 2 h, which shows that the difference between measured results and Ciddor's equation is less than 9.6×10-8, and the standard deviation of that difference is 5.9×10-8. The relative uncertainty of the measured refractive index of air is estimated to be 8.6×10-8. The data update rate is 0.2 Hz, making it applicable under conditions in which air refractive index fluctuates fast.
Corsica: A Multi-Mission Absolute Calibration Site
NASA Astrophysics Data System (ADS)
Bonnefond, P.; Exertier, P.; Laurain, O.; Guinle, T.; Femenias, P.
2013-09-01
In collaboration with the CNES and NASA oceanographic projects (TOPEX/Poseidon and Jason), the OCA (Observatoire de la Côte d'Azur) developed a verification site in Corsica since 1996, operational since 1998. CALibration/VALidation embraces a wide variety of activities, ranging from the interpretation of information from internal-calibration modes of the sensors to validation of the fully corrected estimates of the reflector heights using in situ data. Now, Corsica is, like the Harvest platform (NASA side) [14], an operating calibration site able to support a continuous monitoring with a high level of accuracy: a 'point calibration' which yields instantaneous bias estimates with a 10-day repeatability of 30 mm (standard deviation) and mean errors of 4 mm (standard error). For a 35-day repeatability (ERS, Envisat), due to a smaller time series, the standard error is about the double ( 7 mm).In this paper, we will present updated results of the absolute Sea Surface Height (SSH) biases for TOPEX/Poseidon (T/P), Jason-1, Jason-2, ERS-2 and Envisat.
Predicting Stability Constants for Uranyl Complexes Using Density Functional Theory
Vukovic, Sinisa; Hay, Benjamin P.; Bryantsev, Vyacheslav S.
2015-04-02
The ability to predict the equilibrium constants for the formation of 1:1 uranyl:ligand complexes (log K 1 values) provides the essential foundation for the rational design of ligands with enhanced uranyl affinity and selectivity. We also use density functional theory (B3LYP) and the IEFPCM continuum solvation model to compute aqueous stability constants for UO 2 2+ complexes with 18 donor ligands. Theoretical calculations permit reasonably good estimates of relative binding strengths, while the absolute log K 1 values are significantly overestimated. Accurate predictions of the absolute log K 1 values (root mean square deviation from experiment < 1.0 for logmore » K 1 values ranging from 0 to 16.8) can be obtained by fitting the experimental data for two groups of mono and divalent negative oxygen donor ligands. The utility of correlations is demonstrated for amidoxime and imide dioxime ligands, providing a useful means of screening for new ligands with strong chelate capability to uranyl.« less
The major influence of the atmosphere on intracranial pressure: an observational study.
Herbowski, Leszek
2017-01-01
The impact of the atmosphere on human physiology has been studied widely within the last years. In practice, intracranial pressure is a pressure difference between intracranial compartments and the surrounding atmosphere. This means that gauge intracranial pressure uses atmospheric pressure as its zero point, and therefore, this method of pressure measurement excludes the effects of barometric pressure's fluctuation. The comparison of these two physical quantities can only take place through their absolute value relationship. The aim of this study is to investigate the direct effect of barometric pressure on the absolute intracranial pressure homeostasis. A prospective observational cross-sectional open study was conducted in Szczecin, Poland. In 28 neurosurgical patients with suspected normal-pressure hydrocephalus, intracranial intraventricular pressure was monitored in a sitting position. A total of 168 intracranial pressure and atmospheric pressure measurements were performed. Absolute atmospheric pressure was recorded directly. All values of intracranial gauge pressure were converted to absolute pressure (the sum of gauge intracranial pressure and local absolute atmospheric pressure). The average absolute mean intracranial pressure in the patients is 1006.6 hPa (95 % CI 1004.5 to 1008.8 hPa, SEM 1.1), and the mean absolute atmospheric pressure is 1007.9 hPa (95 % CI 1006.3 to 1009.6 hPa, SEM 0.8). The observed association between atmospheric and intracranial pressure is strongly significant (Spearman correlation r = 0.87, p < 0.05) and all the measurements are perfectly reliable (Bland-Altman coefficient is 4.8 %). It appears from this study that changes in absolute intracranial pressure are related to seasonal variation. Absolute intracranial pressure is shown to be impacted positively by atmospheric pressure.
The major influence of the atmosphere on intracranial pressure: an observational study
NASA Astrophysics Data System (ADS)
Herbowski, Leszek
2017-01-01
The impact of the atmosphere on human physiology has been studied widely within the last years. In practice, intracranial pressure is a pressure difference between intracranial compartments and the surrounding atmosphere. This means that gauge intracranial pressure uses atmospheric pressure as its zero point, and therefore, this method of pressure measurement excludes the effects of barometric pressure's fluctuation. The comparison of these two physical quantities can only take place through their absolute value relationship. The aim of this study is to investigate the direct effect of barometric pressure on the absolute intracranial pressure homeostasis. A prospective observational cross-sectional open study was conducted in Szczecin, Poland. In 28 neurosurgical patients with suspected normal-pressure hydrocephalus, intracranial intraventricular pressure was monitored in a sitting position. A total of 168 intracranial pressure and atmospheric pressure measurements were performed. Absolute atmospheric pressure was recorded directly. All values of intracranial gauge pressure were converted to absolute pressure (the sum of gauge intracranial pressure and local absolute atmospheric pressure). The average absolute mean intracranial pressure in the patients is 1006.6 hPa (95 % CI 1004.5 to 1008.8 hPa, SEM 1.1), and the mean absolute atmospheric pressure is 1007.9 hPa (95 % CI 1006.3 to 1009.6 hPa, SEM 0.8). The observed association between atmospheric and intracranial pressure is strongly significant (Spearman correlation r = 0.87, p < 0.05) and all the measurements are perfectly reliable (Bland-Altman coefficient is 4.8 %). It appears from this study that changes in absolute intracranial pressure are related to seasonal variation. Absolute intracranial pressure is shown to be impacted positively by atmospheric pressure.
Desensitizing the posterior interosseous nerve alters wrist proprioceptive reflexes.
Hagert, Elisabet; Persson, Jonas K E
2010-07-01
The presence of wrist proprioceptive reflexes after stimulation of the dorsal scapholunate interosseous ligament has previously been described. Because this ligament is primarily innervated by the posterior interosseous nerve (PIN) we hypothesized altered ligamento-muscular reflex patterns following desensitization of the PIN. Eight volunteers (3 women, 5 men; mean age, 26 y; range 21-28 y) participated in the study. In the first study on wrist proprioceptive reflexes (study 1), the scapholunate interosseous ligament was stimulated through a fine-wire electrode with 4 1-ms bipolar pulses at 200 Hz, 30 times consecutively, while EMG activity was recorded from the extensor carpi radialis brevis, extensor carpi ulnaris, flexor carpi radialis, and flexor carpi ulnaris, with the wrist in extension, flexion, radial deviation, and ulnar deviation. After completion of study 1, the PIN was anesthetized in the radial aspect of the fourth extensor compartment using 2-mL lidocaine (10 mg/mL) infiltration anesthesia. Ten minutes after desensitization, the experiment was repeated as in study 1. The average EMG results from the 30 consecutive stimulations were rectified and analyzed using Student's t-test. Statistically significant changes in EMG amplitude were plotted along time lines so that the results of study 1 and 2 could be compared. Dramatic alterations in reflex patterns were observed in wrist flexion, radial deviation, and ulnar deviation following desensitization of the PIN, with an average of 72% reduction in excitatory reactions. In ulnar deviation, the inhibitory reactions of the extensor carpi ulnaris were entirely eliminated. In wrist extension, no differences in the reflex patterns were observed. Wrist proprioception through the scapholunate ligament in flexion, radial deviation, and ulnar deviation depends on an intact PIN function. The unchanged reflex patterns in wrist extension suggest an alternate proprioceptive pathway for this position. Routine excision of the PIN during wrist surgical procedures should be avoided, as it alters the proprioceptive function of the wrist. Therapeutic IV. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Online pretreatment verification of high-dose rate brachytherapy using an imaging panel
NASA Astrophysics Data System (ADS)
Fonseca, Gabriel P.; Podesta, Mark; Bellezzo, Murillo; Van den Bosch, Michiel R.; Lutgens, Ludy; Vanneste, Ben G. L.; Voncken, Robert; Van Limbergen, Evert J.; Reniers, Brigitte; Verhaegen, Frank
2017-07-01
Brachytherapy is employed to treat a wide variety of cancers. However, an accurate treatment verification method is currently not available. This study describes a pre-treatment verification system that uses an imaging panel (IP) to verify important aspects of the treatment plan. A detailed modelling of the IP was only possible with an extensive calibration performed using a robotic arm. Irradiations were performed with a high dose rate (HDR) 192Ir source within a water phantom. An empirical fit was applied to measure the distance between the source and the detector so 3D Cartesian coordinates of the dwell positions can be obtained using a single panel. The IP acquires 7.14 fps to verify the dwell times, dwell positions and air kerma strength (Sk). A gynecological applicator was used to create a treatment plan that was registered with a CT image of the water phantom used during the experiments for verification purposes. Errors (shifts, exchanged connections and wrong dwell times) were simulated to verify the proposed verification system. Cartesian source positions (panel measurement plane) have a standard deviation of about 0.02 cm. The measured distance between the source and the panel (z-coordinate) have a standard deviation up to 0.16 cm and maximum absolute error of ≈0.6 cm if the signal is close to sensitive limit of the panel. The average response of the panel is very linear with Sk. Therefore, Sk measurements can be performed with relatively small errors. The measured dwell times show a maximum error of 0.2 s which is consistent with the acquisition rate of the panel. All simulated errors were clearly identified by the proposed system. The use of IPs is not common in brachytherapy, however, it provides considerable advantages. It was demonstrated that the IP can accurately measure Sk, dwell times and dwell positions.
Online pretreatment verification of high-dose rate brachytherapy using an imaging panel.
Fonseca, Gabriel P; Podesta, Mark; Bellezzo, Murillo; Van den Bosch, Michiel R; Lutgens, Ludy; Vanneste, Ben G L; Voncken, Robert; Van Limbergen, Evert J; Reniers, Brigitte; Verhaegen, Frank
2017-07-07
Brachytherapy is employed to treat a wide variety of cancers. However, an accurate treatment verification method is currently not available. This study describes a pre-treatment verification system that uses an imaging panel (IP) to verify important aspects of the treatment plan. A detailed modelling of the IP was only possible with an extensive calibration performed using a robotic arm. Irradiations were performed with a high dose rate (HDR) 192 Ir source within a water phantom. An empirical fit was applied to measure the distance between the source and the detector so 3D Cartesian coordinates of the dwell positions can be obtained using a single panel. The IP acquires 7.14 fps to verify the dwell times, dwell positions and air kerma strength (Sk). A gynecological applicator was used to create a treatment plan that was registered with a CT image of the water phantom used during the experiments for verification purposes. Errors (shifts, exchanged connections and wrong dwell times) were simulated to verify the proposed verification system. Cartesian source positions (panel measurement plane) have a standard deviation of about 0.02 cm. The measured distance between the source and the panel (z-coordinate) have a standard deviation up to 0.16 cm and maximum absolute error of ≈0.6 cm if the signal is close to sensitive limit of the panel. The average response of the panel is very linear with Sk. Therefore, Sk measurements can be performed with relatively small errors. The measured dwell times show a maximum error of 0.2 s which is consistent with the acquisition rate of the panel. All simulated errors were clearly identified by the proposed system. The use of IPs is not common in brachytherapy, however, it provides considerable advantages. It was demonstrated that the IP can accurately measure Sk, dwell times and dwell positions.
Ryskina, Kira; Jessica Dine, C; Gitelman, Yevgeniy; Leri, Damien; Patel, Mitesh; Kurtzman, Gregory; Lin, Lisa Y; Epstein, Andrew J
2018-05-22
Social comparison feedback is an increasingly popular strategy that uses performance report cards to modify physician behavior. Our objective was to test the effect of such feedback on the ordering of routine laboratory tests for hospitalized patients, a practice considered overused. This was a single-blinded randomized controlled trial. Between January and June 2016, physicians on six general medicine teams at the Hospital of the University of Pennsylvania were cluster randomized with equal allocation to two arms: (1) those e-mailed a summary of their routine laboratory test ordering vs. the service average for the prior week, linked to a continuously updated personalized dashboard containing patient-level details, and snapshot of the dashboard and (2) those who did not receive the intervention. The primary outcome was the count of routine laboratory test orders placed by a physician per patient-day. We modeled the count of orders by each physician per patient-day after the intervention as a function of trial arm and the physician's order count before the intervention. The count outcome was modeled using negative binomial models with adjustment for clustering within teams. One hundred and fourteen interns and residents participated. We did not observe a statistically significant difference in adjusted reduction in routine laboratory ordering between the intervention and control physicians (physicians in the intervention group ordered 0.14 fewer tests per patient-day than physicians in the control group, 95% CI - 0.56 to 0.27, p = 0.50). Physicians whose absolute ordering rate deviated from the peer rate by more than 1.0 laboratory test per patient-day reduced their laboratory ordering by 0.80 orders per patient-day (95% CI - 1.58 to - 0.02, p = 0.04). Personalized social comparison feedback on routine laboratory ordering did not change targeted behavior among physicians, although there was a significant decrease in orders among participants who deviated more from the peer rate. Clinicaltrials.gov registration: #NCT02330289.
40 CFR 1066.310 - Coastdown procedures for vehicles above 14,000 pounds GVWR.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Calibrate the equipment by running the zero-wind and zero-angle calibrations within 24 hours before... = mean ambient absolute temperature during testing, in K. p act = average ambient pressuring during the...
Study on Growth Rhythm of Juveniles Cistolemmys Flavomarginata for One and Two Years Old
NASA Astrophysics Data System (ADS)
Huang, Bin
Growth of one and two year old Cistolemmys flavomarginata is studied. In natural temperature and under artificial feeding condition, juvenile turtles grow for 180 days in Xinyang, one year old turtle average body weight increased from 18.1 g to 54.5 g, the relative growth rate is 204.1%, the absolute growth rate is 0.21. two year old turtle average body weight increased from 46.8 g to 101.1 g, the relative growth rate is 115.98%, the absolute growth rate is 0.30. But two year old turtle growth rate is slower than that of one year old turtle. The body weight, carapace length, carapace width, plastron length, plastron width and carapace high are correlated positively to daily age. The body weight growth equations of one and two year old turtles are deduced. Compared with other reptiles, whole growth cycle is grasped systemically by the growth patterns.
Statistical properties of edge plasma turbulence in the Large Helical Device
NASA Astrophysics Data System (ADS)
Dewhurst, J. M.; Hnat, B.; Ohno, N.; Dendy, R. O.; Masuzaki, S.; Morisaki, T.; Komori, A.
2008-09-01
Ion saturation current (Isat) measurements made by three tips of a Langmuir probe array in the Large Helical Device are analysed for two plasma discharges. Absolute moment analysis is used to quantify properties on different temporal scales of the measured signals, which are bursty and intermittent. Strong coherent modes in some datasets are found to distort this analysis and are consequently removed from the time series by applying bandstop filters. Absolute moment analysis of the filtered data reveals two regions of power-law scaling, with the temporal scale τ ≈ 40 µs separating the two regimes. A comparison is made with similar results from the Mega-Amp Spherical Tokamak. The probability density function is studied and a monotonic relationship between connection length and skewness is found. Conditional averaging is used to characterize the average temporal shape of the largest intermittent bursts.
NASA Astrophysics Data System (ADS)
Baglivo, Fabricio Hugo; Arini, Pedro David
2011-12-01
Electrocardiographic repolarization abnormalities can be detected by Principal Components Analysis of the T-wave. In this work we studied the efect of signal averaging on the mean value and reproducibility of the ratio of the 2nd to the 1st eigenvalue of T-wave (T21W) and the absolute and relative T-wave residuum (TrelWR and TabsWR) in the ECG during ischemia induced by Percutaneous Coronary Intervention. Also, the intra-subject and inter-subject variability of T-wave parameters have been analyzed. Results showed that TrelWR and TabsWR evaluated from the average of 10 complexes had lower values and higher reproducibility than those obtained from 1 complex. On the other hand T21W calculated from 10 complexes did not show statistical diferences versus the T21W calculated on single beats. The results of this study corroborate that, with a signal averaging technique, the 2nd and the 1st eigenvalue are not afected by noise while the 4th to 8th eigenvalues are so much afected by this, suggesting the use of the signal averaged technique before calculation of absolute and relative T-wave residuum. Finally, we have shown that T-wave morphology parameters present high intra-subject stability.
Anomaly detection in reconstructed quantum states using a machine-learning technique
NASA Astrophysics Data System (ADS)
Hara, Satoshi; Ono, Takafumi; Okamoto, Ryo; Washio, Takashi; Takeuchi, Shigeki
2014-02-01
The accurate detection of small deviations in given density matrices is important for quantum information processing. Here we propose a method based on the concept of data mining. We demonstrate that the proposed method can more accurately detect small erroneous deviations in reconstructed density matrices, which contain intrinsic fluctuations due to the limited number of samples, than a naive method of checking the trace distance from the average of the given density matrices. This method has the potential to be a key tool in broad areas of physics where the detection of small deviations of quantum states reconstructed using a limited number of samples is essential.
Estimation of Local Bone Loads for the Volume of Interest.
Kim, Jung Jin; Kim, Youkyung; Jang, In Gwun
2016-07-01
Computational bone remodeling simulations have recently received significant attention with the aid of state-of-the-art high-resolution imaging modalities. They have been performed using localized finite element (FE) models rather than full FE models due to the excessive computational costs of full FE models. However, these localized bone remodeling simulations remain to be investigated in more depth. In particular, applying simplified loading conditions (e.g., uniform and unidirectional loads) to localized FE models have a severe limitation in a reliable subject-specific assessment. In order to effectively determine the physiological local bone loads for the volume of interest (VOI), this paper proposes a novel method of estimating the local loads when the global musculoskeletal loads are given. The proposed method is verified for the three VOI in a proximal femur in terms of force equilibrium, displacement field, and strain energy density (SED) distribution. The effect of the global load deviation on the local load estimation is also investigated by perturbing a hip joint contact force (HCF) in the femoral head. Deviation in force magnitude exhibits the greatest absolute changes in a SED distribution due to its own greatest deviation, whereas angular deviation perpendicular to a HCF provides the greatest relative change. With further in vivo force measurements and high-resolution clinical imaging modalities, the proposed method will contribute to the development of reliable patient-specific localized FE models, which can provide enhanced computational efficiency for iterative computing processes such as bone remodeling simulations.
Skyrud, Katrine Damgaard; Bray, Freddie; Eriksen, Morten Tandberg; Nilssen, Yngvar; Møller, Bjørn
2016-05-01
Cancer survival varies by place of residence, but it remains uncertain whether this reflects differences in tumour, patient and treatment characteristics (including tumour stage, indicators of socioeconomic status (SES), comorbidity and information on received surgery and radiotherapy) or possibly regional differences in the quality of delivered health care. National population-based data from the Cancer Registry of Norway were used to identify cancer patients diagnosed in 2002-2011 (n = 258,675). We investigated survival from any type of cancer (all cancer sites combined), as well as for the six most common cancers. The effect of adjusting for prognostic factors on regional variations in cancer survival was examined by calculating the mean deviation, defined by the mean absolute deviation of the relative excess risks across health services regions. For prostate cancer, the mean deviation across regions was 1.78 when adjusting for age and sex only, but decreased to 1.27 after further adjustment for tumour stage. For breast cancer, the corresponding mean deviations were 1.34 and 1.27. Additional adjustment for other prognostic factors did not materially change the regional variation in any of the other sites. Adjustment for tumour stage explained most of the regional variations in prostate cancer survival, but had little impact for other sites. Unexplained regional variations after adjusting for tumour stage, SES indicators, comorbidity and type of treatment in Norway may be related to regional inequalities in the quality of cancer care. © 2015 UICC.
Interplanetary medium data book, appendix
NASA Technical Reports Server (NTRS)
King, J. H.
1977-01-01
Computer generated listings of hourly average interplanetary plasma and magnetic field parameters are given. Parameters include proton temperature, proton density, bulk speed, an identifier of the source of the plasma data for the hour, average magnetic field magnitude and cartesian components of the magnetic field. Also included are longitude and latitude angles of the vector made up of the average field components, a vector standard deviation, and an identifier of the source of magnetic field data.
Efficiency at Sorting Cards in Compressed Air
Poulton, E. C.; Catton, M. J.; Carpenter, A.
1964-01-01
At a site where compressed air was being used in the construction of a tunnel, 34 men sorted cards twice, once at normal atmospheric pressure and once at 3½, 2½, or 2 atmospheres absolute pressure. An additional six men sorted cards twice at normal atmospheric pressure. When the task was carried out for the first time, all the groups of men performing at raised pressure were found to yield a reliably greater proportion of very slow responses than the group of men performing at normal pressure. There was reliably more variability in timing at 3½ and 2½ atmospheres absolute than at normal pressure. At 3½ atmospheres absolute the average performance was also reliably slower. When the task was carried out for the second time, exposure to 3½ atmospheres absolute pressure had no reliable effect. Thus compressed air affected performance only while the task was being learnt; it had little effect after practice. No reliable differences were found related to age, to length of experience in compressed air, or to the duration of the exposure to compressed air, which was never less than 10 minutes at 3½ atmospheres absolute pressure. PMID:14180485
NASA Astrophysics Data System (ADS)
Schabel, Matthias C.; DiBella, Edward V. R.; Jensen, Randy L.; Salzman, Karen L.
2010-08-01
Accurate quantification of pharmacokinetic model parameters in tracer kinetic imaging experiments requires correspondingly accurate determination of the arterial input function (AIF). Despite significant effort expended on methods of directly measuring patient-specific AIFs in modalities as diverse as dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), dynamic positron emission tomography (PET), and perfusion computed tomography (CT), fundamental and technical difficulties have made consistent and reliable achievement of that goal elusive. Here, we validate a new algorithm for AIF determination, the Monte Carlo blind estimation (MCBE) method (which is described in detail and characterized by extensive simulations in a companion paper), by comparing AIFs measured in DCE-MRI studies of eight brain tumor patients with results of blind estimation. Blind AIFs calculated with the MCBE method using a pool of concentration-time curves from a region of normal brain tissue were found to be quite similar to the measured AIFs, with statistically significant decreases in fit residuals observed in six of eight patients. Biases between the blind and measured pharmacokinetic parameters were the dominant source of error. Averaged over all eight patients, the mean biases were +7% in K trans, 0% in kep, -11% in vp and +10% in ve. Corresponding uncertainties (median absolute deviation from the best fit line) were 0.0043 min-1 in K trans, 0.0491 min-1 in kep, 0.29% in vp and 0.45% in ve. The use of a published population-averaged AIF resulted in larger mean biases in three of the four parameters (-23% in K trans, -22% in kep, -63% in vp), with the bias in ve unchanged, and led to larger uncertainties in all four parameters (0.0083 min-1 in K trans, 0.1038 min-1 in kep, 0.31% in vp and 0.95% in ve). When blind AIFs were calculated from a region of tumor tissue, statistically significant decreases in fit residuals were observed in all eight patients despite larger deviations of these blind AIFs from the measured AIFs. The observed decrease in root-mean-square fit residuals between the normal brain and tumor tissue blind AIFs suggests that the local blood supply in tumors is measurably different from that in normal brain tissue and that the proposed method is able to discriminate between the two. We have shown the feasibility of applying the MCBE algorithm to DCE-MRI data acquired in brain, finding generally good agreement with measured AIFs and decreased biases and uncertainties relative to the use of a population-averaged AIF. These results demonstrate that the MCBE algorithm is a useful alternative to direct AIF measurement in cases where acquisition of high-quality arterial input function data is difficult or impossible.