Science.gov

Sample records for absolute cleanliness excellent

  1. Surface cleanliness measurement procedure

    DOEpatents

    Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank

    2002-01-01

    A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.

  2. Tools for measuring surface cleanliness

    DOEpatents

    Schroder, Mark Stewart; Woodmansee, Donald Ernest; Beadie, Douglas Frank

    2002-01-01

    A procedure and tools for quantifying surface cleanliness are described. Cleanliness of a target surface is quantified by wiping a prescribed area of the surface with a flexible, bright white cloth swatch, preferably mounted on a special tool. The cloth picks up a substantial amount of any particulate surface contamination. The amount of contamination is determined by measuring the reflectivity loss of the cloth before and after wiping on the contaminated system and comparing that loss to a previous calibration with similar contamination. In the alternative, a visual comparison of the contaminated cloth to a contamination key provides an indication of the surface cleanliness.

  3. Hardware cleanliness methodology and certification

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Lash, Thomas J.; Rawls, J. Richard

    1995-01-01

    Inadequacy of mass loss cleanliness criteria for selection of materials for contamination sensitive uses, and processing of flight hardware for contamination sensitive instruments is discussed. Materials selection for flight hardware is usually based on mass loss (ASTM E-595). However, flight hardware cleanliness (MIL 1246A) is a surface cleanliness assessment. It is possible for materials (e.g. Sil-Pad 2000) to pass ASTM E-595 and fail MIL 1246A class A by orders of magnitude. Conversely, it is possible for small amounts of nonconforming material (Huma-Seal conformal coating) to not present significant cleanliness problems to an optical flight instrument. Effective cleaning (precleaning, precision cleaning, and ultra cleaning) and cleanliness verification are essential for contamination sensitive flight instruments. Polish cleaning of hardware, e.g. vacuum baking for vacuum applications, and storage of clean hardware, e.g. laser optics, is discussed. Silicone materials present special concerns for use in space because of the rapid conversion of the outgassed residues to glass by solar ultraviolet radiation and/or atomic oxygen. Non ozone depleting solvent cleaning and institutional support for cleaning and certification are also discussed.

  4. Surface cleanliness of fluid systems, specification for

    NASA Technical Reports Server (NTRS)

    1995-01-01

    This specification establishes surface cleanliness levels, test methods, cleaning and packaging requirements, and protection and inspection procedures for determining surface cleanliness. These surfaces pertain to aerospace parts, components, assemblies, subsystems, and systems in contact with any fluid medium.

  5. [Cleanliness Norms 1964-1975].

    PubMed

    Noelle-Neumann, E

    1976-01-01

    In 1964 the Institut für Demoskopie Allensbach made a first survey taking stock of norms concerning cleanliness in the Federal Republic of Germany. At that time, 78% of respondents thought that the vogue among young people of cultivating an unkempt look was past or on the wane (Table 1.). Today we know that this fashion was an indicator of more serious desires for change in many different areas like politics, sexual morality, education and that its high point was still to come. In the fall of 1975 a second survey, modelled on the one of 1964, was conducted. Again, it concentrated on norms, not on behavior. As expected, norms have changed over this period but not in a one-directional or simple manner. In general, people are much more large-minded about children's looks: neat, clean school-dress, properly combed hair, clean shoes, all this and also holding their things in order has become less important in 1975 (Table 2). To carry a clean handkerchief is becoming oldfashioned (Table 3). On the other hand, principles of bringing-up children have not loosened concerning personal hygiene - brushing ones teeth, washing hands, feet, and neck, clean fingernails (Table 4). On one item related to protection of the environment, namely throwing around waste paper, standards have even become more strict (Table 5). With regard to school-leavers, norms of personal hygiene have generally become more strict (Table 6). As living standards have gone up and the number of full bathrooms has risen from 42% to 75% of households, norms of personal hygiene have also increased: one warm bath a week seemed enough to 56% of adults in 1964, but to only 32% in 1975 (Table 7). Also standards for changing underwear have changed a lot: in 1964 only 12% of respondents said "every day", in 1975 48% said so (Table 8). Even more stringent norms are applied to young women (Tables 9/10). For comparison: 1964 there were automatic washing machines in 16%, 1975 in 79% of households. Answers to questions

  6. 49 CFR 178.338-15 - Cleanliness.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Containers for Motor Vehicle Transportation § 178.338-15 Cleanliness. A cargo tank constructed for oxygen... 49 Transportation 3 2013-10-01 2013-10-01 false Cleanliness. 178.338-15 Section 178.338-15 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS...

  7. 49 CFR 178.338-15 - Cleanliness.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Containers for Motor Vehicle Transportation § 178.338-15 Cleanliness. A cargo tank constructed for oxygen... 49 Transportation 3 2014-10-01 2014-10-01 false Cleanliness. 178.338-15 Section 178.338-15 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS...

  8. 49 CFR 178.338-15 - Cleanliness.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Containers for Motor Vehicle Transportation § 178.338-15 Cleanliness. A cargo tank constructed for oxygen... 49 Transportation 3 2011-10-01 2011-10-01 false Cleanliness. 178.338-15 Section 178.338-15 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS...

  9. 49 CFR 178.338-15 - Cleanliness.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Containers for Motor Vehicle Transportation § 178.338-15 Cleanliness. A cargo tank constructed for oxygen... 49 Transportation 3 2012-10-01 2012-10-01 false Cleanliness. 178.338-15 Section 178.338-15 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS...

  10. 49 CFR 178.338-15 - Cleanliness.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Cleanliness. 178.338-15 Section 178.338-15... Specifications for Containers for Motor Vehicle Transportation § 178.338-15 Cleanliness. A cargo tank constructed for oxygen service must be thoroughly cleaned to remove all foreign material in accordance with CGA...

  11. [Cleanliness in the operating room].

    PubMed

    Suzuki, Toshiyasu

    2010-05-01

    With regard to recent findings in the cleanliness of the operating room, concerning handwashing and performing operations, the traditional method of excessive scrubbing using a brush is not effective, and handwashing using only an alcohol-containing antiseptic hand rub (rubbing method) has become common practice. Use of a brush has already been abolished in some medical institutions. In addition, sterilized water used for handwashing when performing operations has no scientific basis and use of tap water is considered sufficient. Furthermore, the concept of operating room zoning has also undergone a dramatic change. It was discovered that a layout focusing on work efficiency is more desirable than the one that follows an excessively rigid zoning pattern. One-footwear System not requiring change of shoes also has various advantages in improving the efficiency of the operation room, and this is thought to become commonplace in the future. PMID:20486565

  12. Automated Steel Cleanliness Analysis Tool (ASCAT)

    SciTech Connect

    Gary Casuccio; Michael Potter; Fred Schwerer; Dr. Richard J. Fruehan; Dr. Scott Story

    2005-12-30

    The objective of this study was to develop the Automated Steel Cleanliness Analysis Tool (ASCATTM) to permit steelmakers to evaluate the quality of the steel through the analysis of individual inclusions. By characterizing individual inclusions, determinations can be made as to the cleanliness of the steel. Understanding the complicating effects of inclusions in the steelmaking process and on the resulting properties of steel allows the steel producer to increase throughput, better control the process, reduce remelts, and improve the quality of the product. The ASCAT (Figure 1) is a steel-smart inclusion analysis tool developed around a customized next-generation computer controlled scanning electron microscopy (NG-CCSEM) hardware platform that permits acquisition of inclusion size and composition data at a rate never before possible in SEM-based instruments. With built-in customized ''intelligent'' software, the inclusion data is automatically sorted into clusters representing different inclusion types to define the characteristics of a particular heat (Figure 2). The ASCAT represents an innovative new tool for the collection of statistically meaningful data on inclusions, and provides a means of understanding the complicated effects of inclusions in the steel making process and on the resulting properties of steel. Research conducted by RJLG with AISI (American Iron and Steel Institute) and SMA (Steel Manufactures of America) members indicates that the ASCAT has application in high-grade bar, sheet, plate, tin products, pipes, SBQ, tire cord, welding rod, and specialty steels and alloys where control of inclusions, whether natural or engineered, are crucial to their specification for a given end-use. Example applications include castability of calcium treated steel; interstitial free (IF) degasser grade slag conditioning practice; tundish clogging and erosion minimization; degasser circulation and optimization; quality assessment/steel cleanliness; slab, billet

  13. Spacecraft Magnetic Cleanliness Prediction and Control

    NASA Astrophysics Data System (ADS)

    Weikert, S.; Mehlem, K.; Wiegand, A.

    2012-05-01

    The paper describes a sophisticated and realistic control and prediction method for the magnetic cleanliness of spacecraft, covering all phases of a project till the final system test. From the first establishment of the so-called magnetic moment allocation list the necessary boom length can be determined. The list is then continuously updated by real unit test results with the goal to ensure that the magnetic cleanliness budget is not exceeded at a given probability level. A complete example is described. The synthetic spacecraft modeling which predicts only quite late the final magnetic state of the spacecraft is also described. Finally, the most important cleanliness verification, the spacecraft system test, is described shortly with an example. The emphasis of the paper is put on the magnetic dipole moment allocation method.

  14. Achieving and maintaining cleanliness in NIF amplifiers

    SciTech Connect

    Burnham, A. K.; Horvath, J. A.; Letts, S. A.; Menapace, J. A.; Stowers, I. F.

    1998-07-28

    Cleanliness measurements made on AMPLAB prototype National Ignition Facility (NIF) laser amplifiers during assembly, cassette transfer, and amplifier operation are summarized. These measurements include particle counts from surface cleanliness assessments using filter swipe techniques and from airborne particle monitoring. Results are compared with similar measurements made on the Beamlet and Nova lasers and in flashlamp test fixtures. Observations of Class 100,000 aerosols after flashlamp firings are discussed. Comparisons are made between typical damage densities on laser amplifier optics from Novette, NOVA, Beamlet, and AMPLAB.

  15. 7 CFR 58.129 - Cleanliness.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Cleanliness. 58.129 Section 58.129 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE...

  16. Precision Clean Hardware: Maintenance of Fluid Systems Cleanliness

    NASA Technical Reports Server (NTRS)

    Sharp, Sheila; Pedley, Mike; Bond, Tim; Quaglino, Joseph; Lorenz, Mary Jo; Bentz, Michael; Banta, Richard; Tolliver, Nancy; Golden, John; Levesque, Ray

    2003-01-01

    The ISS fluid systems are so complex that fluid system cleanliness cannot be verified at the assembly level. A "build clean / maintain clean" approach was used by all major fluid systems: Verify cleanliness at the detail and subassembly level. Maintain cleanliness during assembly.

  17. Cleaning and Cleanliness Measurement of Additive Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Mitchell, Mark A.; Raley, Randy

    2016-01-01

    The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surfaces of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The methods for establishing objective cleanliness acceptance limits will be discussed.

  18. Cleaning and Cleanliness Measurement of Additive Manufactured Parts

    NASA Technical Reports Server (NTRS)

    Welker, Roger W.; Mitchell, Mark A.

    2015-01-01

    The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surface of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The six commonly used methods for establishing objective cleanliness acceptance limits will be discussed. Special emphasis shall focus on the use of multiple extraction, a technique that has been demonstrated for additively manufactured parts.

  19. Magnetic cleanliness verification approach on tethered satellite

    NASA Technical Reports Server (NTRS)

    Messidoro, Piero; Braghin, Massimo; Grande, Maurizio

    1990-01-01

    Magnetic cleanliness testing was performed on the Tethered Satellite as the last step of an articulated verification campaign aimed at demonstrating the capability of the satellite to support its TEMAG (TEthered MAgnetometer) experiment. Tests at unit level and analytical predictions/correlations using a dedicated mathematical model (GANEW program) are also part of the verification activities. Details of the tests are presented, and the results of the verification are described together with recommendations for later programs.

  20. Cleanliness validation of NIF small optics

    NASA Astrophysics Data System (ADS)

    Chow, Robert; Bickel, Robert C.; Ertel, John; Pryatel, James; Loomis, Gary E.; Stowers, Irving F.; Taylor, John R.

    2002-09-01

    The National Ignition Facility will be the highest energy laser in the world when completed. Many small optics (less than or equal to 14" in diameter) have stringent transport efficiency and some have very high laser fluence requirements. For optics to sustain high spectral efficiencies and survive high fluences for a 30-year operation, these optics have cleanliness requirements to assure optimal laser system performance. These optical components have insufficient surface areas to validate the particulate and organic contamination requirements by methods used for mechanical parts. Also, the common validation techniques require some sort of surface contact which is not compatible with handling of laser optics. This presentation describes alternate cleanliness validation methods developed for the NIF small optical components. An organic validation procedure was devised based on the spectral transmission sensitivity to contamination layers on coated and uncoated fused silica windows. Optics were scanned in the near infrared before and after an application of a specific amount of organic contamination onto the surface. Changes in transmission correlated to organic contamination levels and used to determine non-volatile organic contamination optics. A validation method for particulate contamination was demonstrated on a large window, showing that acceptable cleanliness levels could be achieved after a wet-wipe and inspection with a high intensity light. The method is similar to that used to inspect the surface quality of optical components.

  1. Cleanliness Validation of NIF Small Optics

    SciTech Connect

    Chow, R; Bickel, R; Ertel, J; Pryatel, J; Loomis, G; Stowers, I; Taylor, J R

    2002-05-07

    The National Ignition Facility will be the highest energy laser in the world when completed. Many small optics ({le} 14 inches in diameter) have stringent transport efficiency and some have very high laser fluence requirements. For optics to sustain high spectral efficiencies and survive high fluences for a 30-year operation, these optics have cleanliness requirements to assure optimal laser system performance. These optical components have insufficient surface areas to validate the particulate and organic contamination requirements by methods used for mechanical parts. Also, the common validation techniques require some sort of surface contact which is not compatible with handling of laser optics. This presentation describes alternate cleanliness validation methods developed for the NIF small optical components. An organic validation procedure was devised based on the spectral transmission sensitivity to contamination layers on coated and uncoated fused silica windows. Optics were scanned in the near infrared before and after an application of a specific amount of organic contamination onto the surface. Changes in transmission correlated to organic contamination levels and used to determine non-volatile organic contamination optics. A validation method for particulate contamination was demonstrated on a large window, showing that acceptable cleanliness levels could be achieved after a wet-wipe and inspection with a high intensity light. The method is similar to that used to inspect the surface quality of optical components.

  2. Does cleanliness influence moral judgments? Response effort moderates the effect of cleanliness priming on moral judgments

    PubMed Central

    Huang, Jason L.

    2014-01-01

    Whether cleanliness influences moral judgments has recently become a topic of debate in the psychological literature. After the initial report that activating the notion of physical purity can result in less severe moral judgments (Schnall et al., 2008a), a direct replication (Johnson et al., 2014a) with much larger sample sizes failed to yield similar findings. The current paper examines the possibility that only non-conscious activation of the cleanliness concept, as achieved in participants with low response effort on priming materials, can produce the expected effect. An online replication (Study 1, N = 214) provided evidence that, when participants exerted low (yet still acceptable) levels of response effort to the experimental material, cleanliness priming led to more lenient moral judgments than neutral priming. An online experiment (Study 2, N = 440; replicated in Study 2a, N = 436) manipulating participants’ effort on the priming task (low vs. high) supported the hypothesized mechanism. Specifically, respondents in the low response effort group were instructed to complete the priming task as quickly as possible without too much attention, and the cleanliness priming resulted in less extreme moral judgments than the neutral condition as expected. In contrast, respondents in the high response effort group were instructed to perform to the best of their ability on the priming task, with a non-significant difference on moral ratings between cleanliness and neutral conditions. In addition to helping resolve the controversy regarding the cleanliness hypothesis, the current paper calls into attention the role of response effort in the execution and replication of priming studies. PMID:25414690

  3. Back to basics: surgical attire and cleanliness.

    PubMed

    Spruce, Lisa

    2014-01-01

    A clean perioperative environment is beneficial for both patients and perioperative team members, and surgical attire is the foundation of cleanliness. Perioperative personnel should adhere to general hygiene and wear clean, facility-laundered surgical attire in the health care facility. Implementing a surgical attire policy can be challenging because attire is linked to personal preference and image. There are ways to achieve compliance with attire recommendations as well as to implement an attire policy. To help ensure success, perioperative nurses should be prepared to help educate other team members and participate in monitoring and compliance efforts. PMID:24369978

  4. Dirt reference standard for surface cleanliness measurements

    NASA Astrophysics Data System (ADS)

    Orzi, D. J. O.; Bilmes, G. M.

    2016-08-01

    Thin films based on polymer poly(isobutyl methacrylate) (PIBMA), doped with carbon black particles deposited on steel plate substrates are proposed as dirt reference standards for cleanliness accreditation methods, particularly for instruments based on laser ablation. The films were made with the spin-coating method, obtaining layers with thickness between 4 and 17 μm. Carbon black particles with sizes smaller than 100 nm and concentrations between 1 and 27.6 mgr/cm3 were used. Characterization of the films was made by using absorbance measurements and laser ablation-induced photoacoustic.

  5. Automated Counting of Particles To Quantify Cleanliness

    NASA Technical Reports Server (NTRS)

    Rhode, James

    2005-01-01

    A machine vision system, similar to systems used in microbiological laboratories to count cultured microbes, has been proposed for quantifying the cleanliness of nominally precisely cleaned hardware by counting residual contaminant particles. The system would include a microscope equipped with an electronic camera and circuitry to digitize the camera output, a personal computer programmed with machine-vision and interface software, and digital storage media. A filter pad, through which had been aspirated solvent from rinsing the hardware in question, would be placed on the microscope stage. A high-resolution image of the filter pad would be recorded. The computer would analyze the image and present a histogram of sizes of particles on the filter. On the basis of the histogram and a measure of the desired level of cleanliness, the hardware would be accepted or rejected. If the hardware were accepted, the image would be saved, along with other information, as a quality record. If the hardware were rejected, the histogram and ancillary information would be recorded for analysis of trends. The software would perceive particles that are too large or too numerous to meet a specified particle-distribution profile. Anomalous particles or fibrous material would be flagged for inspection.

  6. A strategic cleaning assessment program: menu cleanliness at restaurants.

    PubMed

    Choi, Jinkyung; Almanza, Barbara; Nelson, Douglas; Neal, Jay; Sirsat, Sujata

    2014-06-01

    The importance of clean food contact surfaces has been recognized; however, the importance of cleanliness on nonfood contact surfaces such as menus may be underestimated. The aim of the study described in this article was to determine the cleanliness of restaurant menus, evaluate typical cleaning methods used in a restaurant, and provide recommendations for improving menu cleanliness. The authors' study used an adenosine triphosphate meter to assess the cleanliness of the menus. A pretest identified the most commonly touched areas of the menu by consumers. Based on the results of the pretest, menus were collected from casual-family dining restaurants and analyzed for cleanliness. Results suggested that menus should be cleaned after each shift and that menus distributed by the staff when guests are seated are cleaner than those kept on the table. PMID:24988660

  7. New Developments in Magnetostatic Cleanliness Modeling

    NASA Astrophysics Data System (ADS)

    Mehlem, K.; Wiegand, A.; Weickert, S.

    2012-05-01

    The paper describes improvements and extensions of the multiple magnetic dipole modeling method (MDM) for cleanliness verification which had been introduced by the author1 in 1977 and then applied during 3 decades to numerous international projects. The solutions of specific modeling problems which had been left unsolved so far, are described in the present paper. Special attention is given to the ambiguities of MDM solutions caused by the limited data coverage available. Constraint handling by the constraint-free NLP solver, optimal MDM sizing and multiple-point far-field compensation techniques are presented. The recent extension of the MDM method to field gradient data is formulated and demonstrated by an example. Finally, a complex MDM application (Ulysses) is presented. Finally, a short description of the MDM software GAMAG, recently introduced by the author1, is given.

  8. Criteria evaluation for cleanliness testing phase 0

    SciTech Connect

    Meltzer, Michael; Koester, Carolyn; Stefanni, Chris

    1999-02-04

    The Boeing Company (Boeing) contracted with Lawrence Livermore National Laboratory (LLNL) to develop criteria for evaluating the efficacy of its parts cleaning processes. In particular, LLNL and Boeing are attempting to identify levels of contamination that lead to parts failures. Sufficient contamination to cause impairment of anodizing, alodining, painting, or welding operations is considered a "part failure." In the "Phase 0" part of the project that was recently completed, preliminary analyses of aluminum substrates were performed as a first step in determining suitable cleanliness criteria for actual Boeing parts made from this material. A wide spread of contamination levels was specified for the Phase 0 test coupons, in the hopes of finding a range in which an appropriate cleanliness specification might lie. It was planned that, based on the results of the Phase 0 testing, further more detailed analyses ("Phase 1 testing") would be performed in order to more accurately identify the most appropriate criteria. For the Phase 0 testing, Boeing supplied LLNL with 3" x 6" and 3" x 10" aluminum test panels which LLNL contaminated with measured amounts of typical hydrocarbon substances encountered in Boeing' s fabrication operations. The panels were then subjected by Boeing to normal cleaning procedures, after which they went through one of the following sets of operations: l anodizing and primer painting . alodining (chromating) and primer painting l welding The coatings or welds were then examined by both Boeing and LLNL to determine whether any of the operations were impaired, and whether there was a correlation between contamination level and damage to the parts. The experimental approach and results are described in detail.

  9. Cleanliness verification process at Martin Marietta Astronautics

    NASA Astrophysics Data System (ADS)

    King, Elizabeth A.; Giordano, Thomas J.

    1994-06-01

    The Montreal Protocol and the 1990 Clean Air Act Amendments mandate CFC-113, other chlorinated fluorocarbons (CFC's) and 1,1,1-Trichloroethane (TCA) be banned from production after December 31, 1995. In response to increasing pressures, the Air Force has formulated policy that prohibits purchase of these solvents for Air Force use after April 1, 1994. In response to the Air Force policy, Martin Marietta Astronautics is in the process of eliminating all CFC's and TCA from use at the Engineering Propulsion Laboratory (EPL), located on Air Force property PJKS. Gross and precision cleaning operations are currently performed on spacecraft components at EPL. The final step of the operation is a rinse with a solvent, typically CFC-113. This solvent is then analyzed for nonvolatile residue (NVR), particle count and total filterable solids (TFS) to determine cleanliness of the parts. The CFC-113 used in this process must be replaced in response to the above policies. Martin Marietta Astronautics, under contract to the Air Force, is currently evaluating and testing alternatives for a cleanliness verification solvent. Completion of test is scheduled for May, 1994. Evaluation of the alternative solvents follows a three step approach. This first is initial testing of solvents picked from literature searches and analysis. The second step is detailed testing of the top candidates from the initial test phase. The final step is implementation and validation of the chosen alternative(s). Testing will include contaminant removal, nonvolatile residue, material compatibility and propellant compatibility. Typical materials and contaminants will be tested with a wide range of solvents. Final results of the three steps will be presented as well as the implementation plan for solvent replacement.

  10. Finding a benchmark for monitoring hospital cleanliness.

    PubMed

    Mulvey, D; Redding, P; Robertson, C; Woodall, C; Kingsmore, P; Bedwell, D; Dancer, S J

    2011-01-01

    This study evaluated three methods for monitoring hospital cleanliness. The aim was to find a benchmark that could indicate risk to patients from a contaminated environment. We performed visual monitoring, ATP bioluminescence and microbiological screening of five clinical surfaces before and after detergent-based cleaning on two wards over a four-week period. Five additional sites that were not featured in the routine domestic specification were also sampled. Measurements from all three methods were integrated and compared in order to choose appropriate levels for routine monitoring. We found that visual assessment did not reflect ATP values nor environmental contamination with microbial flora including Staphylococcus aureus and meticillin-resistant S. aureus (MRSA). There was a relationship between microbial growth categories and the proportion of ATP values exceeding a chosen benchmark but neither reliably predicted the presence of S. aureus or MRSA. ATP values were occasionally diverse. Detergent-based cleaning reduced levels of organic soil by 32% (95% confidence interval: 16-44%; P<0.001) but did not necessarily eliminate indicator staphylococci, some of which survived the cleaning process. An ATP benchmark value of 100 relative light units offered the closest correlation with microbial growth levels <2.5 cfu/cm(2) (receiver operating characteristic ROC curve sensitivity: 57%; specificity: 57%). In conclusion, microbiological and ATP monitoring confirmed environmental contamination, persistence of hospital pathogens and measured the effect on the environment from current cleaning practices. This study has provided provisional benchmarks to assist with future assessment of hospital cleanliness. Further work is required to refine practical sampling strategy and choice of benchmarks. PMID:21129820

  11. Easy Absolute Values? Absolutely

    ERIC Educational Resources Information Center

    Taylor, Sharon E.; Mittag, Kathleen Cage

    2015-01-01

    The authors teach a problem-solving course for preservice middle-grades education majors that includes concepts dealing with absolute-value computations, equations, and inequalities. Many of these students like mathematics and plan to teach it, so they are adept at symbolic manipulations. Getting them to think differently about a concept that they…

  12. Effect of melt cleanliness on the properties

    NASA Astrophysics Data System (ADS)

    Samuel, F. H.; Liu, H.; Samuel, A. M.

    1993-07-01

    An experimental study was conducted to examine the effect of melt cleanliness with respect to the presence of inclusions on the properties of an Al-10 wt pct Si metal matrix composite (MMC) reinforced with 10 vol pct SiC particles. The occurrence of inclusions was controlled by filtra- tion, using ceramic foam filters of 10, 20, and 30 ppi sizes, under gravity and pressure. Test bars obtained from filtered and unfiltered melt castings, prepared from fresh (as-received) and recycled composite materials, were T6-tempered and tensile tested at room temperature. The casting quality was examined using X-ray radiography. The results indicate that various factors influence the casting quality and mechanical properties of the cast composite. The A12O3 films and spinel MgAl2O4 — the main inclusions observed in the present composite — are chiefly responsible for the degradation in the mechanical properties. In addition, SiC sedimentation, Al4C3 formation, the hydrogen level of the melt, and the starting material used can also influence these properties. Fracture studies reveal that the inclusions and associated microvoids act as the crack initiation sites during composite fracture. Simple filtration using 10 ppi ceramic foam filters under gravity serves adequately in removing these inclusions and producing the desired mechanical properties.

  13. Determining cleanliness levels along the neutron tube manufacturing line

    SciTech Connect

    Lopez, E.P.; Montoya, M.G.

    1997-02-01

    A study is underway to identify a rapid, easy method for determining cleanliness levels during the manufacture of neutron tubes. Due to high reliability concerns associated with neutron tubes, cleanliness levels of metal and ceramic piece parts are critical. Sandia has traditionally used quantitative surface analytical methods, such as Auger Electron Spectroscopy and X-ray Photoelectron Spectroscopy for determining cleanliness levels. A critical disadvantage of these techniques is the time required to perform them. More rapid, reliable methods are needed for in-line testing of neutron tube assemblies. Several methods including contact angle, MESERAN, Fourier Transform Infrared Spectroscopy, and Optically Stimulated Electron Emission measurements are being evaluated as potential candidates. Cleanliness levels for each of these methods have been compared to Auger Electron Spectroscopy results, after processing samples through similar test conditions. An attempt was made to correlate the results from the alternative methods to those of Auger Electron Spectroscopy. Test results are presented.

  14. Improved Detection Technique for Solvent Rinse Cleanliness Verification

    NASA Technical Reports Server (NTRS)

    Hornung, S. D.; Beeson, H. D.

    2001-01-01

    The NASA White Sands Test Facility (WSTF) has an ongoing effort to reduce or eliminate usage of cleaning solvents such as CFC-113 and its replacements. These solvents are used in the final clean and cleanliness verification processes for flight and ground support hardware, especially for oxygen systems where organic contaminants can pose an ignition hazard. For the final cleanliness verification in the standard process, the equivalent of one square foot of surface area of parts is rinsed with the solvent, and the final 100 mL of the rinse is captured. The amount of nonvolatile residue (NVR) in the solvent is determined by weight after the evaporation of the solvent. An improved process of sampling this rinse, developed at WSTF, requires evaporation of less than 2 mL of the solvent to make the cleanliness verification. Small amounts of the solvent are evaporated in a clean stainless steel cup, and the cleanliness of the stainless steel cup is measured using a commercially available surface quality monitor. The effectiveness of this new cleanliness verification technique was compared to the accepted NVR sampling procedures. Testing with known contaminants in solution, such as hydraulic fluid, fluorinated lubricants, and cutting and lubricating oils, was performed to establish a correlation between amount in solution and the process response. This report presents the approach and results and discusses the issues in establishing the surface quality monitor-based cleanliness verification.

  15. Evaluating denture cleanliness of patients in a regional dental hospital.

    PubMed

    Mylonas, P; Attrill, D C; Walmsley, A D

    2016-08-12

    Aims To evaluate the quality of clinical record keeping and determine quality of denture cleanliness; record baseline denture cleanliness for 60 patients; introduce denture hygiene instruction (DHI); and then re-assess the patients for improvement and enhanced record keeping.Methods Analysis of patients' denture hygiene instruction record keeping (n = 60) was undertaken retrospectively. The Denture Cleanliness Index (DCI) was utilised to assess denture cleanliness (best score 0, worst score 4). Baseline DCI scores were taken and individual DHI was delivered. After one month, patients were reviewed and scored, with record keeping quality analysed.Results At baseline, 11.7% (n = 7) of patients had DCI scores of ≤2, improving to 93.8% (n = 45) after one month, demonstrating short-term improvement in denture cleanliness. Only 63% (n = 38) of patients had evidence of a record of DHI within their notes at baseline, improving to 100% at recall.Conclusions New patient information leaflet and clinical guidelines on denture hygiene have been written and implemented. The results of this study suggest that this may be a relatively straightforward method to achieve a short-term improvement in denture cleanliness. The implementation of a DCI score is helpful in allowing patients to improve denture hygiene and its wider use is supported. PMID:27514347

  16. Sensor for the working surface cleanliness definition in vacuum

    NASA Astrophysics Data System (ADS)

    Deulin, E. A.; Mashurov, S. S.; Gatsenko, A. A.

    2016-07-01

    Modern development of nanotechnology as one of the modern science priority directions is impossible to imagine without the use of vacuum systems and technologies. And the better the vacuum (lower the pressure), the “cleaner” we get a surface, which is very important for nanotechnology. Determination of the cleanliness of the surface or the amount of molecular layers of adsorbed gases on the working surface of the products especially in industry, where the cleanliness of the working surface is a key parameter of the technological process and has a significant influence on the output parameters of the final product is the main goal of this work.

  17. Use of a fluorescent marker for assessing hospital bathroom cleanliness.

    PubMed

    Fattorini, Mattia; Ceriale, Emma; Nante, Nicola; Lenzi, Daniele; Manzi, Pietro; Basagni, Claudia; Messina, Gabriele

    2016-09-01

    A fluorescent marker was used to assess the efficacy of daily cleaning in hospital en suite bathrooms. We applied the marker on 218 surfaces and we assigned a score according how completely the mark had been removed. We found significant statistical differences among different surfaces and wards (P < .05). Microbiologic contamination and marker removal score did not seem to be correlated. Differences in cleanliness may indicate discrepancies in cleaning procedures. Fluorescent marker proved to be a practical and effective method and it could be adopted as a first-level control system to assess hospital cleanliness. PMID:27179392

  18. New Facility for S/C Magnetic Cleanliness Program

    NASA Astrophysics Data System (ADS)

    Polirpo, A.; Cucca, M.

    2012-05-01

    Detailed magnetic cleanliness programs in space systems are mandatory, especially for Earth and interplanetary missions carrying magnetometers used for measuring magnetic fields or for a stringent attitude control. In order to cope with these demands, TAS-I (Thales Alenia Space - Italia) Torino, traditionally involved in the development and AIT (Assembly Integration and Test) of scientific satellites, has decided to enhance its actual own capability through the acquisition of a new MCF (Magnetic Cleanliness Facility), adequate to support testing of spacecraft with stringent magnetic requirements. The aim of this paper is to introduce the basic features of this facility and the foreseen capabilities. Such facility will first be used during the early stage of the program Bepi Colombo, and consistent advantages are expected with respect to the MCF used in TAS-I Torino in the past.

  19. Investigation of cleanliness verification techniques for rocket engine hardware

    NASA Technical Reports Server (NTRS)

    Fritzemeier, Marilyn L.; Skowronski, Raymund P.

    1995-01-01

    Oxidizer propellant systems for liquid-fueled rocket engines must meet stringent cleanliness requirements for particulate and nonvolatile residue. These requirements were established to limit residual contaminants which could block small orifices or ignite in the oxidizer system during engine operation. Limiting organic residues in high pressure oxygen systems is particularly important. The current method of cleanliness verification used by Rocketdyne requires an organic solvent flush of the critical hardware surfaces. The solvent is filtered and analyzed for particulate matter, followed by gravimetric determination of the nonvolatile residue (NVR) content of the filtered solvent. The organic solvents currently specified for use (1,1,1-trichloroethane and CFC-113) are ozone-depleting chemicals slated for elimination by December 1995. A test program is in progress to evaluate alternative methods for cleanliness verification that do not require the use of ozone-depleting chemicals and that minimize or eliminate the use of solvents regulated as hazardous air pollutants or smog precursors. Initial results from the laboratory test program to evaluate aqueous-based methods and organic solvent flush methods for NVR verification are provided and compared with results obtained using the current method. Evaluation of the alternative methods was conducted using a range of contaminants encountered in the manufacture of rocket engine hardware.

  20. Investigation of Cleanliness Verification Techniques for Rocket Engine Hardware

    NASA Technical Reports Server (NTRS)

    Fritzemeier, Marilyn L.; Skowronski, Raymund P.

    1994-01-01

    Oxidizer propellant systems for liquid-fueled rocket engines must meet stringent cleanliness requirements for particulate and nonvolatile residue. These requirements were established to limit residual contaminants which could block small orifices or ignite in the oxidizer system during engine operation. Limiting organic residues in high pressure oxygen systems, such as in the Space Shuttle Main Engine (SSME), is particularly important. The current method of cleanliness verification for the SSME uses an organic solvent flush of the critical hardware surfaces. The solvent is filtered and analyzed for particulate matter followed by gravimetric determination of the nonvolatile residue (NVR) content of the filtered solvent. The organic solvents currently specified for use (1, 1, 1-trichloroethane and CFC-113) are ozone-depleting chemicals slated for elimination by December 1995. A test program is in progress to evaluate alternative methods for cleanliness verification that do not require the use of ozone-depleting chemicals and that minimize or eliminate the use of solvents regulated as hazardous air pollutants or smog precursors. Initial results from the laboratory test program to evaluate aqueous-based methods and organic solvent flush methods for NVR verification are provided and compared with results obtained using the current method. Evaluation of the alternative methods was conducted using a range of contaminants encountered in the manufacture of rocket engine hardware.

  1. Introducing "Excel"

    ERIC Educational Resources Information Center

    Tyrrell, Sidney

    2006-01-01

    In this brief article, the author instructs teachers on how to produce an interactive spreadsheet from scratch in about 20 minutes and en route equip themselves and their students, with handy "Excel" skills. The aim is to introduce the basics of "Excel," plus some fun bits, speedily and with a purpose; producing something that is useful in its own…

  2. Absolute Zero

    NASA Astrophysics Data System (ADS)

    Donnelly, Russell J.; Sheibley, D.; Belloni, M.; Stamper-Kurn, D.; Vinen, W. F.

    2006-12-01

    Absolute Zero is a two hour PBS special attempting to bring to the general public some of the advances made in 400 years of thermodynamics. It is based on the book “Absolute Zero and the Conquest of Cold” by Tom Shachtman. Absolute Zero will call long-overdue attention to the remarkable strides that have been made in low-temperature physics, a field that has produced 27 Nobel Prizes. It will explore the ongoing interplay between science and technology through historical examples including refrigerators, ice machines, frozen foods, liquid oxygen and nitrogen as well as much colder fluids such as liquid hydrogen and liquid helium. A website has been established to promote the series: www.absolutezerocampaign.org. It contains information on the series, aimed primarily at students at the middle school level. There is a wealth of material here and we hope interested teachers will draw their student’s attention to this website and its substantial contents, which have been carefully vetted for accuracy.

  3. Absolute Summ

    NASA Astrophysics Data System (ADS)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  4. 49 CFR 174.715 - Cleanliness of transport vehicles after use.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Cleanliness of transport vehicles after use. 174... RAIL Detailed Requirements for Class 7 (Radioactive) Materials § 174.715 Cleanliness of transport vehicles after use. (a) Each transport vehicle used for transporting Class 7 (radioactive) materials...

  5. 49 CFR 174.715 - Cleanliness of transport vehicles after use.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Cleanliness of transport vehicles after use. 174... RAIL Detailed Requirements for Class 7 (Radioactive) Materials § 174.715 Cleanliness of transport vehicles after use. (a) Each transport vehicle used for transporting Class 7 (radioactive) materials...

  6. 49 CFR 174.715 - Cleanliness of transport vehicles after use.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Cleanliness of transport vehicles after use. 174... RAIL Detailed Requirements for Class 7 (Radioactive) Materials § 174.715 Cleanliness of transport vehicles after use. (a) Each transport vehicle used for transporting Class 7 (radioactive) materials...

  7. 49 CFR 174.715 - Cleanliness of transport vehicles after use.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Cleanliness of transport vehicles after use. 174... RAIL Detailed Requirements for Class 7 (Radioactive) Materials § 174.715 Cleanliness of transport vehicles after use. (a) Each transport vehicle used for transporting Class 7 (radioactive) materials...

  8. 49 CFR 174.715 - Cleanliness of transport vehicles after use.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Cleanliness of transport vehicles after use. 174... RAIL Detailed Requirements for Class 7 (Radioactive) Materials § 174.715 Cleanliness of transport vehicles after use. (a) Each transport vehicle used for transporting Class 7 (radioactive) materials...

  9. GRAZING-ANGLE FOURIER TRANSFORM INFRARED SPECTROSCOPY FOR ONLINE SURFACE CLEANLINESS VERIFICATION. YEAR 1

    EPA Science Inventory

    As part of the Online Surface Cleanliness Project, the Naval Facilities Engineering Service Center (NFESC) conducted a study of grazing-angle reflectance Fourier Transform Infrared (FTIR) Spectroscopy as a tool for online cleanliness verification at Department of Defense (DoD) cl...

  10. Why Excel?

    ERIC Educational Resources Information Center

    Barreto, Humberto

    2015-01-01

    This article is not the usual Excel pedagogy fare in that it does not provide an application or example taught via a spreadsheet. Instead, it briefly reviews the history of spreadsheets in the economics classroom and explores the current environment, with an emphasis on modern learning theory. The conclusion is not surprising: spreadsheets improve…

  11. The use of filter media to determine filter cleanliness

    NASA Astrophysics Data System (ADS)

    Van Staden, S. J.; Haarhoff, J.

    It is general believed that a sand filter starts its life with new, perfectly clean media, which becomes gradually clogged with each filtration cycle, eventually getting to a point where either head loss or filtrate quality starts to deteriorate. At this point the backwash cycle is initiated and, through the combined action of air and water, returns the media to its original perfectly clean state. Reality, however, dictates otherwise. Many treatment plants visited a decade or more after commissioning are found to have unacceptably dirty filter sand and backwash systems incapable of returning the filter media to a desired state of cleanliness. In some cases, these problems are common ones encountered in filtration plants but many reasons for media deterioration remain elusive, falling outside of these common problems. The South African conditions of highly eutrophic surface waters at high temperatures, however, exacerbate the problems with dirty filter media. Such conditions often lead to the formation of biofilm in the filter media, which is shown to inhibit the effective backwashing of sand and carbon filters. A systematic investigation into filter media cleanliness was therefore started in 2002, ending in 2005, at the University of Johannesburg (the then Rand Afrikaans University). This involved media from eight South African Water Treatment Plants, varying between sand and sand-anthracite combinations and raw water types from eutrophic through turbid to low-turbidity waters. Five states of cleanliness and four fractions of specific deposit were identified relating to in situ washing, column washing, cylinder inversion and acid-immersion techniques. These were measured and the results compared to acceptable limits for specific deposit, as determined in previous studies, though expressed in kg/m 3. These values were used to determine the state of the filters. In order to gain greater insight into the composition of the specific deposits stripped from the media, a

  12. Chlorhexidine to Maintain Cleanliness of Restroom Door Handles.

    PubMed

    Young, Holly; Plumb, Zara; Stevenson, James; Tibbett, Annabelle; Rawson, Alexander; Thompsett, Joseph; Asif, Mehroze; Gunasekara, Mignonne; Beresford-Peirse, Thomas; Miller, Stuart; Blunt, Mark

    2015-11-01

    Restroom internal door handles have the potential to become contaminated by pathogenic bacteria, particularly because frequent breakdowns occur in hand hygiene. Cleaning these door handles periodically could reduce this cross-contamination risk. The sustained effect following cleaning with chlorhexidine could be beneficial in restroom facilities as cleaning episodes are of necessity at time intervals. The cleaning efficacies and residual effects of Sani Cloth CHG 2% wipes were investigated in a double-blinded randomized crossover controlled trial in a school setting. No significant difference occurred in initial cleaning efficacy; however, following a six-hour period of use by pupils of the restroom facilities, the internal door handles wiped with Sani-Cloth CHG 2% wipes were significantly less contaminated than those with the control wipe (14% v. 32%, p = .02). Cleaning with Sani-Cloth CHG 2% wipes demonstrated significant improvements in the continuous cleanliness of restroom door handles during use with this simple and inexpensive technique. PMID:26638670

  13. Mir Environmental Effects Payload and Returned Mir Solar Panel Cleanliness

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Humes, Donald H.; Kinard, William H.

    2000-01-01

    The MIR Environmental Effects Payload (MEEP) was attached to the Docking Module of the MIR space station for 18 months during calendar years 1996 and 1997 (March 1996, STS 76 to October 1997, STS 86). A solar panel array with more than 10 years space exposure was removed from the MIR core module in November 1997, and returned to Earth in January, 1998, STS 89. MEEP and the returned solar array are part of the International Space Station (ISS) Risk Mitigation Program. This space flight hardware has been inspected and studied by teams of space environmental effects (SEE) investigators for micrometeoroid and space debris effects, space exposure effects on materials, and electrical performance. This paper reports changes in cleanliness of parts of MEEP and the solar array due to the space exposures. Special attention is given to the extensive water soluble residues deposited on some of the flight hardware surfaces. Directionality of deposition and chemistry of these residues are discussed.

  14. Stall cleanliness and stall temperature of two different freestall bases.

    PubMed

    Wadsworth, B A; Stone, A E; Clark, J D; Ray, D L; Bewley, J M

    2015-06-01

    The objective of this study was to describe the differences in freestall cleanliness and stall temperature between a barn with Dual Chamber Cow Waterbeds (DCCW; Advanced Comfort Technology, Reedsburg, WI) and a barn with rubber-filled mattresses at the University of Kentucky Coldstream Dairy Research Farm from January 18, 2012, to May 3, 2013. Stall cleanliness was measured twice weekly (n=134) by the same 2 observers using a 0.91 m×0.91 m wire grid containing 128 equally sized rectangles (10.16 cm×5.08 cm). This grid was centered at the rear portion of the stall; a rectangle that was visibly wet or had any amount of feces present was defined as a dirty rectangle. Weekly stall temperature (n=66) was measured by the same observer during a.m. milkings in the same predetermined stalls. Feces and wet sawdust were removed from the stalls before stall temperatures were acquired. Temperatures were obtained using a handheld thermometer at 30.48 cm above the stall base as determined via dual laser measurements. Stall temperature was measured on the front, middle, and back of the stall first with clean sawdust and then with the sawdust removed from the stall and wiped clean with a towel. Daily temperature-humidity index (THI) was calculated using Kentucky climate data calculated through the University of Kentucky College of Agriculture via a data logger, located 5.63 km from the Coldstream Dairy Farm. Stall cleanliness was not different between the DCCW barn (26.09±0.89 rectangles) and the rubber-filled mattress barn (23.70±0.89 rectangles). Mean THI throughout the study was 64.39±0.82. Stall temperature was different among THI categories. Temperature-humidity index categories 1 (coldest), 2, 3, and 4 (warmest) had THI ranges of 22.94 to 50.77, 50.77 to 64.88, 64.88 to 78.75, and 78.75 to 101.59, respectively. Stall temperatures (°C; least squares means±SE) were 2.26±0.30, 8.86±0.30, 15.52±0.30, and 20.95±0.30 for THI categories 1 to 4, respectively. Stalls with

  15. Evaluation of Steel Cleanliness in a Steel Deoxidized Using Al

    NASA Astrophysics Data System (ADS)

    Castro-Cedeño, Edgar-Ivan; Herrera-Trejo, Martín; Castro-Román, Manuel; Castro-Uresti, Fabián; López-Cornejo, Monserrat

    2016-06-01

    The effect of magnesium in the aluminum used as a deoxidizer on the cleanliness of steel was studied throughout a steelmaking route for the production of thin slabs. Two deoxidizers with different Mg contents were used. The Mg content of a "typical" deoxidizer was ~0.5 wt pct Mg, whereas that for an alternative deoxidizer was ~2 wt pct Mg. The inclusion population at different stages of the steelmaking process was characterized in terms of chemical composition, number, and size distribution. The inclusion modification path shows that the solid Al2O3 and Al2O3-MgO inclusions formed in the early stage of the steel ladle treatment are modified into Al2O3-MgO-CaO liquid and MgO-Al2O3-liquid inclusions. Although some slight differences were observed in the ladle furnace samples, the chemical composition of inclusions was similar in the samples taken at the mold of the continuous casting, regardless of the deoxidizer used. Gumbel, generalized extreme value (GEV), and generalized Pareto (GP) distributions were used for the description of the size distribution. The GEV and GP distributions resulted in proper distributions to describe the evolution of size distribution throughout the steelmaking process. Furthermore, no statistically significant differences between inclusion size distributions resulting from the use of either deoxidizer were found.

  16. Environmental surface cleanliness and the potential for contamination during handwashing.

    PubMed

    Griffith, Christopher J; Malik, Rifhat; Cooper, Rose A; Looker, Nick; Michaels, Barry

    2003-04-01

    Effective handwashing (including drying) is important in infection control. The ability of the various stages of handwashing to decrease skin-surface microbial counts has been documented. However, an important element, environmental surface cleanliness, and the potential for contamination of hands during the process has not been well studied or quantified. An examination of the adenosine triphosphate (a measure of residual organic soil), bacterial, and staphylococcal load on ward handwash station surfaces, which could be touched during handwashing, is reported. Hand contact surfaces tested consisted of approximately 620 each of: faucet handles, soap dispenser activator mechanisms, and folded paper-towel dispenser exits. Failure rates in excess of benchmark clean values were higher with adenosine triphosphate assays than microbial counts. This could indicate the presence of a higher level of general organic debris (eg, skin cells) as opposed to microbial contamination or could reflect greater assay sensitivity. Faucet handles were more likely to be contaminated and be in excess of benchmark values than paper-towel dispenser exits. However, the latter are likely to be the final surface touched during the handwashing process and overall nearly 20% were above microbiologic benchmark values. Many of the organisms isolated were staphylococci and the results are discussed within the context of microbial cross-contamination and potential pathogen spread. PMID:12665742

  17. Evaluation of Cleanliness Test Methods for Spacecraft PCB Assemblies

    NASA Astrophysics Data System (ADS)

    Tegehall, P.-E.; Dunn, B. D.

    2006-10-01

    Ionic contamination on printed-circuit-board assemblies may cause current leakage and short-circuits. The present cleanliness requirement in ECSS-Q-70-08, "The manual soldering of high-reliability electrical connections", is that the ionic contamination shall be less than 1.56 fl-glcm2 NaCI equivalents. The relevance of the method used for measurement of the ionic contamination level, resistivity of solvent extract, has been questioned. Alternative methods are ion chromatography and measurement of surface insulation resistance, but these methods also have their drawbacks. These methods are first described and their advantages and drawbacks are discussed. This is followed by an experimental evaluation of the three methods. This was done by soldering test vehicles at four manufacturers of space electronics using their ordinary processes for soldering and cleaning printed board assemblies. The experimental evaluation showed that the ionic contamination added by the four assemblers was very small and well below the acceptance criterion in ECSS-Q-70-80. Ion-chromatography analysis showed that most of the ionic contamination on the cleaned assembled boards originated from the hot-oil fusing of the printed circuit boards. Also, the surface insulation resistance was higher on the assembled boards compared to the bare printed circuit boards. Since strongly activated fluxes are normally used when printed circuit boards are hot-oil fused, it is essential that they are thoroughly cleaned in order to achieve low contamination levels on the final printed-board assemblies.

  18. Passing excellence

    NASA Astrophysics Data System (ADS)

    Tsoupikova, Daria

    2007-02-01

    This paper describes the research and development of a virtual reality visualization project "Passing excellence" about the world famous architectural ensemble "Kizhi". The Kizhi Pogost is located on an island in Lake Onega in northern Karelia in Russia. It is an authentic museum of an ancient wood building tradition which presents a unique artistic achievement. This ensemble preserves a concentration of masterpieces of the Russian heritage and is included in the List of Most Endangered Sites of the World Monuments Watch protected by World Heritage List of UNESCO. The project strives to create a unique virtual observation of the dynamics of the architectural changes of the museum area beginning from the 15th Century up to the 21st Century. The visualization is being created to restore the original architecture of Kizhi island based on the detailed photographs, architectural and geometric measurements, textural data, video surveys and resources from the Kizhi State Open-Air Museum archives. The project is being developed using Electro, an application development environment for the tiled display high-resolution graphics visualization system and can be shown on the virtual reality systems such as the GeoWall TM and the C-Wall.

  19. Ojirami-Ugbo: the village where the god of cleanliness is worshipped.

    PubMed

    Aletor, G A

    1999-06-01

    The beliefs and practices of the people of Ojirami-Ugbo, who worship Atta, the god of cleanliness, have been reported. A laboratory survey showed significant medical benefits in those health measures adopted by the people. PMID:11043005

  20. How Clean Are Hotel Rooms? Part II: Examining the Concept of Cleanliness Standards.

    PubMed

    Almanza, Barbara A; Kirsch, Katie; Kline, Sheryl Fried; Sirsat, Sujata; Stroia, Olivia; Choi, Jin Kyung; Neal, Jay

    2015-01-01

    Hotel room cleanliness is based on observation and not on microbial assessment even though recent reports suggest that infections may be acquired while staying in hotel rooms. Exploratory research in the first part of the authors' study was conducted to determine if contamination of hotel rooms occurs and whether visual assessments are accurate indicators of hotel room cleanliness. Data suggested the presence of microbial contamination that was not reflective of visual assessments. Unfortunately, no standards exist for interpreting microbiological data and other indicators of cleanliness in hotel rooms. The purpose of the second half of the authors' study was to examine cleanliness standards in other industries to see if they might suggest standards in hotels. Results of the authors' study indicate that standards from other related industries do not provide analogous criteria, but do provide suggestions for further research. PMID:26427263

  1. Technical Tension Between Achieving Particulate and Molecular Organic Environmental Cleanliness: Data from Astromaterial Curation Laboratories

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Burkett, P. J.

    2011-01-01

    NASA Johnson Space Center operates clean curation facilities for Apollo lunar, Antarctic meteorite, stratospheric cosmic dust, Stardust comet and Genesis solar wind samples. Each of these collections is curated separately due unique requirements. The purpose of this abstract is to highlight the technical tensions between providing particulate cleanliness and molecular cleanliness, illustrated using data from curation laboratories. Strict control of three components are required for curating samples cleanly: a clean environment; clean containers and tools that touch samples; and use of non-shedding materials of cleanable chemistry and smooth surface finish. This abstract focuses on environmental cleanliness and the technical tension between achieving particulate and molecular cleanliness. An environment in which a sample is manipulated or stored can be a room, an enclosed glovebox (or robotic isolation chamber) or an individual sample container.

  2. Cleanliness audit of clinical surfaces and equipment: who cleans what?

    PubMed

    Anderson, R E; Young, V; Stewart, M; Robertson, C; Dancer, S J

    2011-07-01

    Current guidelines recommend regular cleaning of clinical equipment. We monitored items on a surgical ward for predominant user, hand-touch frequency, cleaning responsibilities and measurement of organic soil. Equipment was assessed in triplicate against a cleanliness benchmark of 100 relative light units (RLU) using the Hygiena® ATP system. There were 44 items, of which 21 were cleaned by clinical support workers (CSWs), five by domestic staff; three by nurses, three by doctors, and 12 with no designated cleaning responsibility. Geometric mean RLUs ranged from 60 to 550/100 cm² for small items such as hand-gel containers, bed control, blood pressure cuff and clinical notes; with similar values of 80-540/100 cm² RLU for larger items such as electrocardiogram machine, defibrillator, trolleys and tables. Overall geometric mean was 249/100 cm² RLU for all surfaces, with 84% (37 of 44) items exceeding the 100RLU benchmark. Of 27 items cleaned by clinical staff, 24 (89%) failed the benchmark. Of 12 sites with no cleaning specification, 11 (92%) failed the benchmark. Three of seven 'clean' sites (<100/100 cm² RLU) were cleaned by domestic staff. Average log(10) RLU of surfaces cleaned by domestics were 64% lower compared with surfaces cleaned by CSWs (95% confidence interval: 35%, 80%; P=0.019). In conclusion, clinical equipment frequently demonstrates high levels of organic soil, whether or not items have assigned cleaning responsibility. These findings suggest that cleaning practices for clinical equipment may require review, along with education of staff with specific cleaning responsibilities. PMID:21497943

  3. Teaching Absolute Value Meaningfully

    ERIC Educational Resources Information Center

    Wade, Angela

    2012-01-01

    What is the meaning of absolute value? And why do teachers teach students how to solve absolute value equations? Absolute value is a concept introduced in first-year algebra and then reinforced in later courses. Various authors have suggested instructional methods for teaching absolute value to high school students (Wei 2005; Stallings-Roberts…

  4. Organic cleanliness of the Mars Science Laboratory sample transfer chain.

    PubMed

    Blakkolb, B; Logan, C; Jandura, L; Okon, A; Anderson, M; Katz, I; Aveni, G; Brown, K; Chung, S; Ferraro, N; Limonadi, D; Melko, J; Mennella, J; Yavrouian, A

    2014-07-01

    One of the primary science goals of the Mars Science Laboratory (MSL) Rover, Curiosity, is the detection of organics in Mars rock and regolith. To achieve this, the Curiosity rover includes a robotic sampling system that acquires rock and regolith samples and delivers it to the Sample Analysis at Mars (SAM) instrument on board the rover. In order to provide confidence that any significant organics detection result was Martian and not terrestrial in origin, a requirement was levied on the flight system (i.e., all sources minus the SAM instrument) to impart no more than 36 parts per billion (ppb by weight) of total reduced carbon terrestrial contamination to any sample transferred to the SAM instrument. This very clean level was achieved by a combination of a rigorous contamination control program on the project, and then using the first collected samples for a "dilution cleaning" campaign of the sample chain prior to delivering a sample to the SAM instrument. Direct cleanliness assays of the sample-contacting and other Flight System surfaces during pre-launch processing were used as inputs to determine the number of dilution cleaning samples needed once on Mars, to enable delivery of suitably clean samples to the SAM experiment. Taking into account contaminant redistribution during launch thorough landing of the MSL on Mars, the amount of residue present on the sampling hardware prior to the time of first dilution cleaning sample acquisition was estimated to be 60 ng/cm(2) on exposed outer surfaces of the sampling hardware and 20 ng/cm(2) on internal sample contacting surfaces; residues consisting mainly of aliphatic hydrocarbons and esters. After three dilution cleaning samples, estimated in-sample contamination level for the first regolith sample delivered to the SAM instrument at the Gale Crater "Rocknest" site was bounded at ≤10 ppb total organic carbon. A Project decision to forego ejecting the dilution cleaning sample and instead transfer the first drill

  5. Organic cleanliness of the Mars Science Laboratory sample transfer chain

    NASA Astrophysics Data System (ADS)

    Blakkolb, B.; Logan, C.; Jandura, L.; Okon, A.; Anderson, M.; Katz, I.; Aveni, G.; Brown, K.; Chung, S.; Ferraro, N.; Limonadi, D.; Melko, J.; Mennella, J.; Yavrouian, A.

    2014-07-01

    One of the primary science goals of the Mars Science Laboratory (MSL) Rover, Curiosity, is the detection of organics in Mars rock and regolith. To achieve this, the Curiosity rover includes a robotic sampling system that acquires rock and regolith samples and delivers it to the Sample Analysis at Mars (SAM) instrument on board the rover. In order to provide confidence that any significant organics detection result was Martian and not terrestrial in origin, a requirement was levied on the flight system (i.e., all sources minus the SAM instrument) to impart no more than 36 parts per billion (ppb by weight) of total reduced carbon terrestrial contamination to any sample transferred to the SAM instrument. This very clean level was achieved by a combination of a rigorous contamination control program on the project, and then using the first collected samples for a "dilution cleaning" campaign of the sample chain prior to delivering a sample to the SAM instrument. Direct cleanliness assays of the sample-contacting and other Flight System surfaces during pre-launch processing were used as inputs to determine the number of dilution cleaning samples needed once on Mars, to enable delivery of suitably clean samples to the SAM experiment. Taking into account contaminant redistribution during launch thorough landing of the MSL on Mars, the amount of residue present on the sampling hardware prior to the time of first dilution cleaning sample acquisition was estimated to be 60 ng/cm2 on exposed outer surfaces of the sampling hardware and 20 ng/cm2 on internal sample contacting surfaces; residues consisting mainly of aliphatic hydrocarbons and esters. After three dilution cleaning samples, estimated in-sample contamination level for the first regolith sample delivered to the SAM instrument at the Gale Crater "Rocknest" site was bounded at ≤10 ppb total organic carbon. A Project decision to forego ejecting the dilution cleaning sample and instead transfer the first drill

  6. Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.

    2016-01-01

    It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 mg/sq m, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems vary considerably. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

  7. Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.

    2016-01-01

    It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 milligrams per square meter, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems, however, vary considerably, notably within the aerospace industry. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

  8. Eosinophil count - absolute

    MedlinePlus

    Eosinophils; Absolute eosinophil count ... the white blood cell count to give the absolute eosinophil count. ... than 500 cells per microliter (cells/mcL). Normal value ranges may vary slightly among different laboratories. Talk ...

  9. Is Cleanliness Next to Godliness? The Role of Housekeeping in Impression Formation

    ERIC Educational Resources Information Center

    Harris, Paul B.; Sachau, Daniel

    2005-01-01

    We conducted a study to determine if the cleanliness of an apartment would affect observer impressions of the resident. Participants (210 female and 126 male undergraduate students) read a story in which a character's apartment was described as clean or dirty or in which no information about housekeeping was provided. For each condition, half the…

  10. An index to quantify street cleanliness: the case of Granada (Spain).

    PubMed

    Sevilla, Aitana; Rodríguez, Miguel Luis; García-Maraver, Angela; Zamorano, Montserrat

    2013-05-01

    Urban surfaces receive waste deposits from natural and human sources, which create a negative visual impact and are identified as potentially significant contributors to water and air pollution. Local councils are usually responsible for the sweep of roads and footpaths to keep the environment clean and free of litter. Quality controls are useful in order to check whether the services are being executed according to the quantity, quality and performance standards that are provided. In this sense, several factors might affect the efficiency of the management of cleaning and waste collection services; however, only a few contributions are available in the literature on the various aspects associated with the level of street cleanliness. In this paper, the suitability of a Cleanliness Index has been checked, for the case of Granada (South of Spain), in order to contribute to the proper management of public expenditure, improving the quality and cost of an essential service for any municipality. Results have concluded that the city exhibits a good level of cleanliness, although the standard of cleaning varied from one area of the city to another. The Cleaning Index fits well to the general situation of the different districts of Granada and thus, it could be considered a useful tool for measuring the level of cleanliness of the streets of the city and for evaluating the organization of the cleaning service, such that an outsourced company would not be responsible for controlling all the cleaning services. PMID:23434128

  11. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  12. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  13. Excellent Teachers' Perspectives on Excellent Teaching

    ERIC Educational Resources Information Center

    Keeley, Jared W.; Ismail, Emad; Buskist, William

    2016-01-01

    Studies of master teaching have investigated a set of qualities that define excellent teaching. However, few studies have investigated master teachers' perspectives on excellent teaching and how it may differ from other faculty or students. The current study investigated award-winning teachers' (N = 50) ratings of the 28 qualities on the teacher…

  14. Developing the Cleanliness Requirements for an Organic-detection Instrument MOMA-MS

    NASA Technical Reports Server (NTRS)

    Perry, Radford; Canham, John; Lalime, Erin

    2015-01-01

    The cleanliness requirements for an organic-detection instrument, like the Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS), on a Planetary Protection Class IVb mission can be extremely stringent. These include surface molecular and particulate, outgassing, and bioburden. The prime contractor for the European Space Agencys ExoMars 2018 project, Thales Alenia Space Italy, provided requirements based on a standard, conservative approach of defining limits which yielded levels that are unverifiable by standard cleanliness verification methods. Additionally, the conservative method for determining contamination surface area uses underestimation while conservative bioburden surface area relies on overestimation, which results in inconsistencies for the normalized reporting. This presentation will provide a survey of the challenge to define requirements that can be reasonably verified and still remain appropriate to the core science of the ExoMars mission.

  15. Identifying risk factors for poor hind limb cleanliness in Danish loose-housed dairy cows.

    PubMed

    Nielsen, B H; Thomsen, P T; Sørensen, J T

    2011-08-01

    The objective of this study was to identify possible risk factors for poor cow hind limb cleanliness in Danish loose-housed, lactating dairy cows. The study was conducted as a cross-sectional study of 1315 cows in 42 commercial Danish dairy herds with primarily Danish Holstein cows. The effect of four cow-level factors (parity, days in milk, daily lying time and lameness) and eight herd-level factors (herd size, milk production, milking system, floor type, access to pasture grazing, floor scraping frequency, hoof bathing frequency and hoof washing frequency) on the risk of having dirtier hind limbs were analysed using ordinal logistic regression fitting a proportional odds model. Cow hind limb cleanliness was scored using an ordinal score from 1 to 4: 1 being clean and 4 being covered in dirt. The odds ratios (ORs) estimated from the proportional odds model depict the effect of a risk factor on the odds of having a higher rather than a lower cleanliness score. First parity cows had an increased risk of being dirtier compared with third parity or older cows (OR=1.70). Compared with late lactation, early and mid lactation were associated with an increased risk of being dirtier (OR=2.07 and 1.33, respectively). Decreasing the daily time lying by 30 min was associated with an increased risk of being dirtier (OR=1.05). Furthermore, an increased risk of being dirtier was found in herds with no pasture access (OR=3.75). PMID:22440353

  16. Absolute biological needs.

    PubMed

    McLeod, Stephen

    2014-07-01

    Absolute needs (as against instrumental needs) are independent of the ends, goals and purposes of personal agents. Against the view that the only needs are instrumental needs, David Wiggins and Garrett Thomson have defended absolute needs on the grounds that the verb 'need' has instrumental and absolute senses. While remaining neutral about it, this article does not adopt that approach. Instead, it suggests that there are absolute biological needs. The absolute nature of these needs is defended by appeal to: their objectivity (as against mind-dependence); the universality of the phenomenon of needing across the plant and animal kingdoms; the impossibility that biological needs depend wholly upon the exercise of the abilities characteristic of personal agency; the contention that the possession of biological needs is prior to the possession of the abilities characteristic of personal agency. Finally, three philosophical usages of 'normative' are distinguished. On two of these, to describe a phenomenon or claim as 'normative' is to describe it as value-dependent. A description of a phenomenon or claim as 'normative' in the third sense does not entail such value-dependency, though it leaves open the possibility that value depends upon the phenomenon or upon the truth of the claim. It is argued that while survival needs (or claims about them) may well be normative in this third sense, they are normative in neither of the first two. Thus, the idea of absolute need is not inherently normative in either of the first two senses. PMID:23586876

  17. Bringing Excellence to Automotive

    NASA Astrophysics Data System (ADS)

    Večeřa, Pavel; Paulová, Iveta

    2012-12-01

    Market situation and development in recent years shows, that organization's ability to meet customer requirements is not enough. Successful organizations are able to exceed the expectations of all stakeholders. They are building their excellence systematically. Our contribution basically how the excellence in automotive is created using EFQM Excellence Model in Total Quality Management.

  18. Excellence in Library Management.

    ERIC Educational Resources Information Center

    Naulty, Deborah

    By emulating traits of high-performing corporations such as those described in the book "In Search of Excellence," the library/information profession can also reach the goal of excellence. Attributes characterizing excellent companies include exhibiting a bias for action; maintaining quality service through closeness to the customer; encouraging…

  19. Preventing Healthcare-Associated Infections by Monitoring the Cleanliness of Medical Devices and Other Critical Points in a Sterilization Service.

    PubMed

    Veiga-Malta, Isabel

    2016-04-01

    It is well known that the common goal of all central sterile supply departments (CSSDs) is to prevent healthcare-associated infections. Such infections entail high costs to society, not only economic but also social. Therefore, delivering safe medical devices and guaranteeing a positive contribution to the control of healthcare-associated infections form the main responsibilities of a CSSD. The monitoring of the effectiveness of medical device cleaning processes is highly recommended. However, ensuring a flawless environment for the preparation, assembly, and packaging of medical devices and clean handling of sterilized items is crucial to achieving the goal of safe medical devices. This study analyzed not only the cleanliness of surgical instruments but also two critical aspects of the surrounding environment: the cleanliness of work surfaces and the cleanliness of workers' hands. To evaluate the cleanliness of surgical instruments, two methods were used: the adenosine triphosphate (ATP) detection method and a residual protein test. It was not the intention of this work to make an exhaustive comparison of these methods. The ATP bioluminescence method was also used for monitoring the cleanliness of work surfaces and workers' hands. The aims of this study were to establish the most suitable method of evaluating the cleanliness of reusable medical devices in the CSSD and to assess the quality of the environment. Assessing the surgical instruments, work surfaces, and staff hands for cleanliness allowed the identification of possible contamination sources and to correct them by improving cleaning/disinfection protocols. Furthermore, the use of ATP monitoring tests of workers' hands highlighted the importance of staff compliance with good practice guidelines. Thus, these results have a positive impact on the CSSD quality system and, consequently, on patient safety. PMID:27100075

  20. Associations between Body Mass Index and Park Proximity, Size, Cleanliness and Recreational Facilities

    PubMed Central

    Quinn, James; Lovasi, Gina; Bader, Michael; Yousefzadeh, Paulette; Weiss, Christopher; Neckerman, Kathryn

    2013-01-01

    Purpose To determine whether body mass index (BMI) is associated with proximity to neighborhood parks, the size of the parks, their cleanliness and the availability of recreational facilities in the parks. Design Cross-sectional. Setting New York City. Subjects 13,102 adults (median age 45 years, 36% male) recruited from 2000–2002. Measures Anthropometric and socio-demographic data from study subjects were linked to Department of Parks & Recreation data on park space, cleanliness, and facilities. Neighborhood level socio-demographic and park proximity metrics were created for half-mile radius circular buffers around each subject’s residence. Proximity to park space was measured as the proportion of the subject’s neighborhood buffer area that was total park space, large park space (a park > 6 acres) and small park space (a park <=6 acres). Analysis Hierarchical linear models were used to determine whether neighborhood park metrics were associated with BMI. Results Higher proximity to large park space was significantly associated with lower BMI (beta = −1.69 95% CI = −2.76, −0.63). Across the population distribution of proximity to large park space, compared to subjects living in neighborhoods at the 10th percentile of the distribution, the covariate adjusted average BMI was estimated to be 0.35 kg/m2 lower for those living in neighborhoods at the 90th percentile. The proportion of neighborhood area that was small park space was not associated with BMI, nor was park cleanliness or the availability of recreational facilities. Conclusions Neighborhood proximity to large park spaces is modestly associated with lower BMI in a diverse urban population. PMID:23448416

  1. The absolute path command

    2012-05-11

    The ap command traveres all symlinks in a given file, directory, or executable name to identify the final absolute path. It can print just the final path, each intermediate link along with the symlink chan, and the permissions and ownership of each directory component in the final path. It has functionality similar to "which", except that it shows the final path instead of the first path. It is also similar to "pwd", but it canmore » provide the absolute path to a relative directory from the current working directory.« less

  2. The absolute path command

    SciTech Connect

    Moody, A.

    2012-05-11

    The ap command traveres all symlinks in a given file, directory, or executable name to identify the final absolute path. It can print just the final path, each intermediate link along with the symlink chan, and the permissions and ownership of each directory component in the final path. It has functionality similar to "which", except that it shows the final path instead of the first path. It is also similar to "pwd", but it can provide the absolute path to a relative directory from the current working directory.

  3. Design considerations in the creation and maintenance of electrostatic cleanliness for solar electrically propelled spacecraft

    NASA Technical Reports Server (NTRS)

    Sellen, J. M., Jr.; Fitzgerald, D. J.

    1975-01-01

    Charge build-up on spacecraft surfaces and resulting zones of electrostatic contamination have been examined for electrically active and electrically passive spacecraft with both conducting and dielectric surface materials, illuminated and nonilluminated surface conditions, and for both inclusion and neglect of free charge effects from photocurrents and ambient space plasma particles. Techniques for measurement and reduction of electrostatic contamination zone extent have been developed for spacecraft with charge release capability. Indicated limitations for contamination cleanup are about 1 volt potential variation from spacecraft to ambient plasma. Bandwidths of electrostatic monitoring and clamping devices extend to several hundred kilohertz for both DC and 'broadband' AC electrostatic cleanliness.

  4. Keyboard cleanliness: a controlled study of the residual effect of chlorhexidine gluconate.

    PubMed

    Jones, Rhiannon; Hutton, Anna; Mariyaselvam, Maryanne; Hodges, Emily; Wong, Katherine; Blunt, Mark; Young, Peter

    2015-03-01

    A controlled trial of once daily cleaning of computer keyboards in an intensive care unit was performed comparing 2% chlorhexidine gluconate-70% isopropyl alcohol (CHG) and a chlorine dioxide-based product used as a standard in our hospital. A study before and after the introduction of once daily keyboard cleaning with CHG in the wider hospital was also completed. Cleaning with CHG showed a sustained and significant reduction in bacterial colony forming units compared with the chlorine dioxide-based product, demonstrating its unique advantage of maintaining continuous keyboard cleanliness over time. PMID:25728156

  5. Melt Cleanliness Comparison of Chlorine Fluxing and Ar Degassing of Secondary Al-4Cu

    NASA Astrophysics Data System (ADS)

    Çolak, Murat; Kayikci, Ramazan; Dispinar, Derya

    2016-07-01

    The treatment of liquid aluminum prior to casting typically consists of purging gas and/or fluxes through the melt. By the use of several chemicals during these operations, several environmental problems can occur. Therefore, in this study, the melt cleanliness of Al-4Cu secondary alloy was investigated by comparing the use of argon degassing with or without chlorine fluxing. Reduced pressure test was used to assess the melt quality. Highest quality melt was obtained by Ar degassing with preheated graphite lance without the need to use any chemicals.

  6. Absolute photoionization cross sections of atomic oxygen

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.; Pareek, P. N.

    1985-01-01

    The absolute values of photoionization cross sections of atomic oxygen were measured from the ionization threshold to 120 A. An auto-ionizing resonance belonging to the 2S2P4(4P)3P(3Do, 3So) transition was observed at 479.43 A and another line at 389.97 A. The experimental data is in excellent agreement with rigorous close-coupling calculations that include electron correlations in both the initial and final states.

  7. Absolute photoionization cross sections of atomic oxygen

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.; Pareek, P. N.

    1982-01-01

    The absolute values of photoionization cross sections of atomic oxygen were measured from the ionization threshold to 120 A. An auto-ionizing resonance belonging to the 2S2P4(4P)3P(3Do, 3So) transition was observed at 479.43 A and another line at 389.97 A. The experimental data is in excellent agreement with rigorous close-coupling calculations that include electron correlations in both the initial and final states.

  8. Leading Others Toward Excellence.

    PubMed

    Hupp, James R

    2015-12-01

    This essay puts forth the proposition that academic program excellence does not arise by accident. Effective leadership is required. To support this proposition, the essay discusses the characteristics common to effective leaders. It then proceeds to use the example of a successful academic oral-maxillofacial surgery department and characteristics of its leader to provide evidence that excellence derives from effective leadership. PMID:26608145

  9. Melding Excellence and Equity.

    ERIC Educational Resources Information Center

    Bennett, David A.

    1983-01-01

    This document examines the issues of educational excellence and equity. The Milwaukee Public School System, Wisconsin, is cited as an example of a desegregation program that both exceeded court requirements of equity and also made a substantial contribution to the goals of excellence in education. The school effectiveness movement, like…

  10. "Excellence" in STEM Education

    ERIC Educational Resources Information Center

    Clark, Aaron C.

    2012-01-01

    So what does it take to achieve excellence in STEM education? That is the title of the author's presentation delivered at International Technology and Engineering Educators Association's (ITEEA's) FTEE "Spirit of Excellence" Breakfast on March 16, 2012, in Long Beach, California. In preparation for this presentation, the author went back and read…

  11. Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

    NASA Technical Reports Server (NTRS)

    Allton, J. H.; Zeigler, R. A.; Calaway, M. J.

    2016-01-01

    The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample

  12. Recognition of Teaching Excellence*

    PubMed Central

    Piascik, Peggy; Medina, Melissa; Pittenger, Amy; Rose, Renee; Creekmore, Freddy; Soltis, Robert; Bouldin, Alicia; Schwarz, Lindsay; Scott, Steven

    2010-01-01

    The 2008-2009 Task Force for the Recognition of Teaching Excellence was charged by the AACP Council of Faculties Leadership to examine teaching excellence by collecting best practices from colleges and schools of pharmacy, evaluating the literature to identify evidence-based criteria for excellent teaching, and recommending appropriate means to acknowledge and reward teaching excellence. This report defines teaching excellence and discusses a variety of ways to assess it, including student, alumni, peer, and self-assessment. The task force identifies important considerations that colleges and schools must address when establishing teaching recognition programs including the purpose, criteria, number and mix of awards, frequency, type of award, and method of nominating and determining awardees. The report concludes with recommendations for the academy to consider when establishing and revising teaching award programs. PMID:21301598

  13. Assessing the cleanliness of surfaces: Innovative molecular approaches vs. standard spore assays

    SciTech Connect

    Cooper, M.; Duc, M.T. La; Probst, A.; Vaishampayan, P.; Stam, C.; Benardini, J.N.; Piceno, Y.M.; Andersen, G.L.; Venkateswaran, K.

    2011-04-01

    A bacterial spore assay and a molecular DNA microarray method were compared for their ability to assess relative cleanliness in the context of bacterial abundance and diversity on spacecraft surfaces. Colony counts derived from the NASA standard spore assay were extremely low for spacecraft surfaces. However, the PhyloChip generation 3 (G3) DNA microarray resolved the genetic signatures of a highly diverse suite of microorganisms in the very same sample set. Samples completely devoid of cultivable spores were shown to harbor the DNA of more than 100 distinct microbial phylotypes. Furthermore, samples with higher numbers of cultivable spores did not necessarily give rise to a greater microbial diversity upon analysis with the DNA microarray. The findings of this study clearly demonstrated that there is not a statistically significant correlation between the cultivable spore counts obtained from a sample and the degree of bacterial diversity present. Based on these results, it can be stated that validated state-of-the-art molecular techniques, such as DNA microarrays, can be utilized in parallel with classical culture-based methods to further describe the cleanliness of spacecraft surfaces.

  14. Improving Cleanliness of 95CrMo Drill Rod Steel by Slag Refining

    NASA Astrophysics Data System (ADS)

    Wang, Linzhu; Yang, Shufeng; Li, Jingshe; Wu, Tuo; Liu, Wei; Xiong, Jiaze

    2016-02-01

    Industrial experiments were performed to improve the cleanliness of 95CrMo drill rod steel by slag refining. Higher steel cleanliness, lower corrosion, and small inclusions were obtained using the optimal slag composition (pctCaO/pctSiO2 = 3.7 to 4, pctCaO/pctAl2O3 = 6 to 8). Layered composite inclusions formed during vacuum decarburizing refining. CaS first precipitated around the spinel and subsequently formed inclusions in which solid CaS-CaO wrapped around the Al2O3-MgO-SiO2-CaO system as the modification and diffusion progressed. The thermodynamic equilibrium between slag and liquid 95CrMo steel at 1873 K (1600 °C) was also studied to understand the effect of slag composition on the oxygen content and absorption capacity for Al2O3. A mathematical model based on an investigation of slag viscosity and the interfacial tension between slag and inclusions was used to predict the size of critical inclusions for different slags. The evolution of typical inclusions is discussed in terms of the study of reactions between slag and steel.

  15. A noncontacting scanning photoelectron emission technique for bonding surface cleanliness inspection

    NASA Technical Reports Server (NTRS)

    Gause, Raymond L.

    1989-01-01

    Molecular contamination of bonding surfaces can drastically affect the bond strength that can be achieved and therefore the structural integrity and reliability of the bonded part. The presence of thin contaminant films on bonding surfaces can result from inadequate or incomplete cleaning methods, from oxide growth during the time between cleaning (such as grit blasting) and bonding, or from failure to properly protect cleaned surfaces from oils, greases, fingerprints, release agents, or deposition of facility airborne molecules generated by adjacent manufacturing or processing operations. Required cleanliness levels for desired bond performance can be determined by testing to correlate bond strength with contaminant type and quantity, thereby establishing the degree of contamination that can be tolerated based on the strength that is needed. Once the maximum acceptable contaminant level is defined, a method is needed to quantitatively measure the contaminant level on the bonding surface prior to bonding to verify that the surface meets the established cleanliness requirement. A photoelectron emission technique for the nondestructive inspection of various bonding surfaces, both metallic and nonmetallic, to provide quantitative data on residual contaminant levels is described. The technique can be used to scan surfaces at speeds of at least 30 ft/min using a servo system to maintain required sensor to surface spacing. The fundamental operation of the photoelectron emission sensor system is explained and the automated scanning system and computer data acquisition hardware and software are described.

  16. Contamination control and cleanliness level integrity for the Space Shuttle Orbiter PLB, payloads and facilities at KSC

    NASA Technical Reports Server (NTRS)

    Bartelson, D.

    1984-01-01

    The PLB, its cargo, and payload canister must satisfy the cleanliness requirements of visual clean (VC) level 1, 2, 3, or special as stated in NASA document SN-C-0005A. The specific level of cleanliness is chosen by the payload bay customer for their mission. During orbiter turnaround processing at KSC, the payload bay is exposed to the environments of the Orbiter Processing Facility (OPF) and the Payload Changeout Room (PCR). In supportive response to the orbiter payload bay/facility interface, it is necessary that the facility environment be controlled and monitored to protect the cleanliness/environmental integrity of the payload bay and its cargo. Techniques used to meet environmental requirements during orbiter processing are introduced.

  17. Excel for Cost Engineers

    NASA Technical Reports Server (NTRS)

    Butts, Glenn C.

    2007-01-01

    Excel is a powerful tool with a plethora of largely unused capabilities that can make the life of an engineer cognizant of them a great deal easier. This paper offers tips, tricks and techniques for better worksheets. Including the use of data validation, conditional formatting, subtotals, text formulas, custom functions and much more. It is assumed that the reader will have a cursory understanding of Excel so the basics will not be covered, if you get hung up try Excel's built in help menus, or a good book.

  18. Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care

    PubMed Central

    2014-01-01

    Background Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). Methods The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. Results The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Conclusions

  19. Electronic Absolute Cartesian Autocollimator

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.

    2006-01-01

    An electronic absolute Cartesian autocollimator performs the same basic optical function as does a conventional all-optical or a conventional electronic autocollimator but differs in the nature of its optical target and the manner in which the position of the image of the target is measured. The term absolute in the name of this apparatus reflects the nature of the position measurement, which, unlike in a conventional electronic autocollimator, is based absolutely on the position of the image rather than on an assumed proportionality between the position and the levels of processed analog electronic signals. The term Cartesian in the name of this apparatus reflects the nature of its optical target. Figure 1 depicts the electronic functional blocks of an electronic absolute Cartesian autocollimator along with its basic optical layout, which is the same as that of a conventional autocollimator. Referring first to the optical layout and functions only, this or any autocollimator is used to measure the compound angular deviation of a flat datum mirror with respect to the optical axis of the autocollimator itself. The optical components include an illuminated target, a beam splitter, an objective or collimating lens, and a viewer or detector (described in more detail below) at a viewing plane. The target and the viewing planes are focal planes of the lens. Target light reflected by the datum mirror is imaged on the viewing plane at unit magnification by the collimating lens. If the normal to the datum mirror is parallel to the optical axis of the autocollimator, then the target image is centered on the viewing plane. Any angular deviation of the normal from the optical axis manifests itself as a lateral displacement of the target image from the center. The magnitude of the displacement is proportional to the focal length and to the magnitude (assumed to be small) of the angular deviation. The direction of the displacement is perpendicular to the axis about which the

  20. Cleanliness and damage measurements of optics in atmospheric sensing high energy lasers

    SciTech Connect

    Harvey, G.A.; Chyba, T.H.; Cimolino, M.C.

    1996-12-31

    Langley Research Center has several atmospheric remote sensing programs which utilize, high energy pulsed lasers. These lasers typically have many damaged optics after several million shots. Damage is defined herein as color changes and/or optical flaws seen in microscopic inspection, and does not necessarily relate to measured performance degradation of the optic. Inspections and measurements of some of these optics indicate that energy thresholds for several million shots damage is about an order of magnitude lower than that for single shot damage. Damage initiation is often at micron size areas at the coating interface, which grows and sometimes develops as erosion of the top of the coating. There is a wide range in polish and coating quality of new optics, even on different faces of the same optic. Military Standard 1246C can be used to provide overall particulate, and molecular film, or nonvolatile residue (NTVR) cleanliness scales. Microscopic inspections and photography at I0x to 500x with brightfield (perpendicular) and darkfield (oblique) illumination are useful in assigning cleanliness levels of new and in-service optics. Microextraction (effecting concentration of molecular films to small areas) provides for enhanced optical detection and surface film chemical analysis by electron-microscope energy-dispersive-spectroscopy (EDS). Similar measurement techniques can be used to characterize and document optical damage initiation and optical damage growth. Surface contamination interferes with and complicates measurements of polish and coating quality, and of optical damage. This work indicates ultrasonic cleaning, and packaging of optics in Teflon sleeves or cups is advantageous over conventional cleaning and packaging for characterization of new optics.

  1. Leg lesions and cleanliness of finishing bulls kept in housing systems with different lying area surfaces.

    PubMed

    Schulze Westerath, H; Gygax, L; Mayer, C; Wechsler, B

    2007-07-01

    The influence of the quality of different lying surfaces on lesions and swellings at the joints as well as on the cleanliness of finishing bulls throughout the fattening period was studied. On 17 farms (623 bulls), pens with fully slatted concrete floors (CONCRETE), with rubber coated slats (RUBBER), with cubicles (CUBICLES, provided with five different types of soft lying mat) and with a littered lying area (STRAW) were compared. Bulls kept on STRAW developed the smallest lesion scores at the joints. In CUBICLES, there was a huge variability in the lesion scores depending on the type of lying mat, ranging from values comparable to STRAW up to and greater than the values for CONCRETE. The highest lesion scores at the carpal joints were found on CONCRETE, with intermediate values on RUBBER and in CUBICLES. At the tarsal joints, lesion scores were similar on CONCRETE and RUBBER and in the same range or worse on most mats in the CUBICLES. Swelling scores were highest on CONCRETE and intermediate on RUBBER and in CUBICLES compared to STRAW. In general, there was a steady increase in the lesion scores of the leg joints throughout the fattening period on CONCRETE, RUBBER and STRAW, whereas on some of the mats in CUBICLES these scores were at a high level from early on in the fattening period. Animals in all the housing systems were clean over the whole fattening period. Littering the lying area in CUBICLES affected neither the lesion scores nor the swelling scores at the joints nor animal cleanliness. In conclusion, both rubber coated slats and cubicles provided with soft lying mats were favourable with regard to the levels of lesions and swellings of the leg joints of finishing bulls compared to concrete slats. However, these levels were even lower in pens with a straw bedded lying area. PMID:16843018

  2. Cleanliness and damage measurements of optics in atmospheric-sensing high-energy lasers

    NASA Astrophysics Data System (ADS)

    Harvey, Gale A.; Chyba, Thomas H.; Cimolino, Marc C.

    1996-05-01

    Langley Research Center has several atmospheric remote sensing programs which utilize high energy pulsed lasers. These lasers typically have many damaged optics after several million shots. Damage is defined herein as color changes and/or optical flaws seen in microscopic inspection, and does not necessarily relate to measured performance degradation of the optic. Inspections and measurements of some of these optics indicate that energy thresholds for several million shots damage is about an order of magnitude lower than that for single shot damage. Damage initiation is often at micron size areas at the coating interface, which grows and sometimes develops as erosion of the top of the coating. There is a wide range in polish and coating quality of new optics, even on different faces of the same optic. Military Standard 1246C can be used to provide overall particulate, and molecular film, or nonvolatile residue cleanliness scales. Microscopic inspections and photography at 10X to 500X with brightfield (perpendicular) and darkfield (oblique) illumination are useful in assigning cleanliness levels of new and in-service optics. Microextraction (effecting concentration of molecular films to small areas) provides for enhanced optical detection and surface film chemical analysis by electron-microscope energy-dispersive-spectroscopy. Similar measurement techniques can be used to characterize and document optical damage initiation and optical damage growth. Surface contamination interferes with and complicated measurements of polish and coating quality, and of optical damage. Our work indicates ultrasonic cleaning, and packaging of optics in Teflon sleeves or cups is advantageous over conventional cleaning and packaging for characterization of new optics.

  3. ABSOLUTE POLARIMETRY AT RHIC.

    SciTech Connect

    OKADA; BRAVAR, A.; BUNCE, G.; GILL, R.; HUANG, H.; MAKDISI, Y.; NASS, A.; WOOD, J.; ZELENSKI, Z.; ET AL.

    2007-09-10

    Precise and absolute beam polarization measurements are critical for the RHIC spin physics program. Because all experimental spin-dependent results are normalized by beam polarization, the normalization uncertainty contributes directly to final physics uncertainties. We aimed to perform the beam polarization measurement to an accuracy Of {Delta}P{sub beam}/P{sub beam} < 5%. The absolute polarimeter consists of Polarized Atomic Hydrogen Gas Jet Target and left-right pairs of silicon strip detectors and was installed in the RHIC-ring in 2004. This system features proton-proton elastic scattering in the Coulomb nuclear interference (CNI) region. Precise measurements of the analyzing power A{sub N} of this process has allowed us to achieve {Delta}P{sub beam}/P{sub beam} = 4.2% in 2005 for the first long spin-physics run. In this report, we describe the entire set up and performance of the system. The procedure of beam polarization measurement and analysis results from 2004-2005 are described. Physics topics of AN in the CNI region (four-momentum transfer squared 0.001 < -t < 0.032 (GeV/c){sup 2}) are also discussed. We point out the current issues and expected optimum accuracy in 2006 and the future.

  4. Elements of Engineering Excellence

    NASA Technical Reports Server (NTRS)

    Blair, J. C.; Ryan, R. S.; Schutzenhofer

    2012-01-01

    The inspiration for this Contract Report (CR) originated in discussions with the director of Marshall Space Flight Center (MSFC) Engineering who asked that we investigate the question: "How do you achieve excellence in aerospace engineering?" Engineering a space system is a complex activity. Avoiding its inherent potential pitfalls and achieving a successful product is a challenge. This CR presents one approach to answering the question of how to achieve Engineering Excellence. We first investigated the root causes of NASA major failures as a basis for developing a proposed answer to the question of Excellence. The following discussions integrate a triad of Technical Understanding and Execution, Partnership with the Project, and Individual and Organizational Culture. The thesis is that you must focus on the whole process and its underlying culture, not just on the technical aspects. In addition to the engineering process, emphasis is given to the need and characteristics of a Learning Organization as a mechanism for changing the culture.

  5. Paternity analysis in Excel.

    PubMed

    Rocheta, Margarida; Dionísio, F Miguel; Fonseca, Luís; Pires, Ana M

    2007-12-01

    Paternity analysis using microsatellite information is a well-studied subject. These markers are ideal for parentage studies and fingerprinting, due to their high-discrimination power. This type of data is used to assign paternity, to compute the average selfing and outcrossing rates and to estimate the biparental inbreeding. There are several public domain programs that compute all this information from data. Most of the time, it is necessary to export data to some sort of format, feed it to the program and import the output to an Excel book for further processing. In this article we briefly describe a program referred from now on as Paternity Analysis in Excel (PAE), developed at IST and IBET (see the acknowledgments) that computes paternity candidates from data, and other information, from within Excel. In practice this means that the end user provides the data in an Excel sheet and, by pressing an appropriate button, obtains the results in another Excel sheet. For convenience PAE is divided into two modules. The first one is a filtering module that selects data from the sequencer and reorganizes it in a format appropriate to process paternity analysis, assuming certain conventions for the names of parents and offspring from the sequencer. The second module carries out the paternity analysis assuming that one parent is known. Both modules are written in Excel-VBA and can be obtained at the address (www.math.ist.utl.pt/~fmd/pa/pa.zip). They are free for non-commercial purposes and have been tested with different data and against different software (Cervus, FaMoz, and MLTR). PMID:17928093

  6. Searching for excellence

    NASA Astrophysics Data System (ADS)

    Yager, Robert E.

    Visits to six school districts which were identified by the National Science Teachers Association's Search for Excellence program were made during 1983 by teams of 17 researchers. The reports were analyzed in search for common characteristics that can explain the requirements necessary for excellent science programs. The results indicate that creative ideas, administrative and community involvement, local ownership and pride, and well-developed in-service programs and implementation strategies are vital. Exceptional teachers with boundless energies also seem to exist where exemplary science programs are found.

  7. The Excellent Researcher

    ERIC Educational Resources Information Center

    Angervall, Petra

    2016-01-01

    The neo-liberal university not only changes systems of governance but also impacts on how subject positions are valued. These changes justify critical questions on how academics manoeuvre in academia. In this study focus is on the told experiences of 18 researchers who describe how they made an excellent career in academia. The results show that…

  8. Reaching for Excellence.

    ERIC Educational Resources Information Center

    Wright, Emmett L.; Perna, Jack A.

    1992-01-01

    Presents the four program goals for biology set forth in the National Science Teacher Association's "A Focus on Excellence: Biology Revisited" to (1) address biosphere, human society, and individual needs; (2) encourage students to experience, understand, and appreciate of natural systems; (3) apply the basic concept of the biosphere; and (4)…

  9. Enlisting Excel--Again

    ERIC Educational Resources Information Center

    Parramore, Keith

    2009-01-01

    In Volume 26, Number 2, we reported on a group case study run for level 3 mathematics students at the University of Brighton. At the core of the study was a quadratic assignment problem, and we reported on attempts by students to use Excel to solve the problem, and on the attendant difficulties. We provided an elegant solution. In this article, we…

  10. Implants as absolute anchorage.

    PubMed

    Rungcharassaeng, Kitichai; Kan, Joseph Y K; Caruso, Joseph M

    2005-11-01

    Anchorage control is essential for successful orthodontic treatment. Each tooth has its own anchorage potential as well as propensity to move when force is applied. When teeth are used as anchorage, the untoward movements of the anchoring units may result in the prolonged treatment time, and unpredictable or less-than-ideal outcome. To maximize tooth-related anchorage, techniques such as differential torque, placing roots into the cortex of the bone, the use of various intraoral devices and/or extraoral appliances have been implemented. Implants, as they are in direct contact with bone, do not possess a periodontal ligament. As a result, they do not move when orthodontic/orthopedic force is applied, and therefore can be used as "absolute anchorage." This article describes different types of implants that have been used as orthodontic anchorage. Their clinical applications and limitations are also discussed. PMID:16463910

  11. Absolute Equilibrium Entropy

    NASA Technical Reports Server (NTRS)

    Shebalin, John V.

    1997-01-01

    The entropy associated with absolute equilibrium ensemble theories of ideal, homogeneous, fluid and magneto-fluid turbulence is discussed and the three-dimensional fluid case is examined in detail. A sigma-function is defined, whose minimum value with respect to global parameters is the entropy. A comparison is made between the use of global functions sigma and phase functions H (associated with the development of various H-theorems of ideal turbulence). It is shown that the two approaches are complimentary though conceptually different: H-theorems show that an isolated system tends to equilibrium while sigma-functions allow the demonstration that entropy never decreases when two previously isolated systems are combined. This provides a more complete picture of entropy in the statistical mechanics of ideal fluids.

  12. Absolute neutrino mass measurements

    NASA Astrophysics Data System (ADS)

    Wolf, Joachim

    2011-10-01

    The neutrino mass plays an important role in particle physics, astrophysics and cosmology. In recent years the detection of neutrino flavour oscillations proved that neutrinos carry mass. However, oscillation experiments are only sensitive to the mass-squared difference of the mass eigenvalues. In contrast to cosmological observations and neutrino-less double beta decay (0v2β) searches, single β-decay experiments provide a direct, model-independent way to determine the absolute neutrino mass by measuring the energy spectrum of decay electrons at the endpoint region with high accuracy. Currently the best kinematic upper limits on the neutrino mass of 2.2eV have been set by two experiments in Mainz and Troitsk, using tritium as beta emitter. The next generation tritium β-experiment KATRIN is currently under construction in Karlsruhe/Germany by an international collaboration. KATRIN intends to improve the sensitivity by one order of magnitude to 0.2eV. The investigation of a second isotope (137Rh) is being pursued by the international MARE collaboration using micro-calorimeters to measure the beta spectrum. The technology needed to reach 0.2eV sensitivity is still in the R&D phase. This paper reviews the present status of neutrino-mass measurements with cosmological data, 0v2β decay and single β-decay.

  13. Absolute neutrino mass measurements

    SciTech Connect

    Wolf, Joachim

    2011-10-06

    The neutrino mass plays an important role in particle physics, astrophysics and cosmology. In recent years the detection of neutrino flavour oscillations proved that neutrinos carry mass. However, oscillation experiments are only sensitive to the mass-squared difference of the mass eigenvalues. In contrast to cosmological observations and neutrino-less double beta decay (0v2{beta}) searches, single {beta}-decay experiments provide a direct, model-independent way to determine the absolute neutrino mass by measuring the energy spectrum of decay electrons at the endpoint region with high accuracy.Currently the best kinematic upper limits on the neutrino mass of 2.2eV have been set by two experiments in Mainz and Troitsk, using tritium as beta emitter. The next generation tritium {beta}-experiment KATRIN is currently under construction in Karlsruhe/Germany by an international collaboration. KATRIN intends to improve the sensitivity by one order of magnitude to 0.2eV. The investigation of a second isotope ({sup 137}Rh) is being pursued by the international MARE collaboration using micro-calorimeters to measure the beta spectrum. The technology needed to reach 0.2eV sensitivity is still in the R and D phase. This paper reviews the present status of neutrino-mass measurements with cosmological data, 0v2{beta} decay and single {beta}-decay.

  14. Studying the Use of Photocatalytic Coatings to Increase Building/Structure Sustainability and Cleanliness at NASA Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Underwood, Lauren

    2013-01-01

    TiO2 coated surfaces demonstrated both visually through photographic representation, and quantitatively, through reflectance measurements that they improved upon the current state of cleanliness upon the surfaces that they were applied to. TiO2 has the potential to both maintain and increase building s sustainability and the overall appearance of cleanliness TiO2 coated slides degraded soot under UV light compared to soot samples on plain uncoated slides under the same conditions Degradation of soot by photocatalysis was far more apparent than degradation of soot by UV light alone This demonstration provides the foundation for a laboratory model that could be used to simulate real world applications for photocatalytic materials Additional research is required to better understand the full potential of TiO2

  15. Bioluminescence ATP Monitoring for the Routine Assessment of Food Contact Surface Cleanliness in a University Canteen

    PubMed Central

    Osimani, Andrea; Garofalo, Cristiana; Clementi, Francesca; Tavoletti, Stefano; Aquilanti, Lucia

    2014-01-01

    ATP bioluminescence monitoring and traditional microbiological analyses (viable counting of total mesophilic aerobes, coliforms and Escherichia coli) were used to evaluate the effectiveness of Sanitation Standard Operating Procedures (SSOP) at a university canteen which uses a HACCP-based approach. To that end, 10 cleaning control points (CPs), including food contact surfaces at risk of contamination from product residues or microbial growth, were analysed during an 8-month monitoring period. Arbitrary acceptability limits were set for both microbial loads and ATP bioluminescence readings. A highly significant correlation (r = 0.99) between the means of ATP bioluminescence readings and the viable counts of total mesophilic aerobes was seen, thus revealing a strong association of these parameters with the level of surface contamination. Among CPs, the raw meat and multi-purpose chopping boards showed the highest criticalities. Although ATP bioluminescence technology cannot substitute traditional microbiological analyses for the determination of microbial load on food contact surfaces, it has proved to be a powerful tool for the real time monitoring of surface cleanliness at mass catering plants, for verify the correct application of SSOP, and hence for their implementation/revision in the case of poor hygiene. PMID:25329534

  16. Bioluminescence ATP monitoring for the routine assessment of food contact surface cleanliness in a university canteen.

    PubMed

    Osimani, Andrea; Garofalo, Cristiana; Clementi, Francesca; Tavoletti, Stefano; Aquilanti, Lucia

    2014-01-01

    ATP bioluminescence monitoring and traditional microbiological analyses (viable counting of total mesophilic aerobes, coliforms and Escherichia coli) were used to evaluate the effectiveness of Sanitation Standard Operating Procedures (SSOP) at a university canteen which uses a HACCP-based approach. To that end, 10 cleaning control points (CPs), including food contact surfaces at risk of contamination from product residues or microbial growth, were analysed during an 8-month monitoring period. Arbitrary acceptability limits were set for both microbial loads and ATP bioluminescence readings. A highly significant correlation (r = 0.99) between the means of ATP bioluminescence readings and the viable counts of total mesophilic aerobes was seen, thus revealing a strong association of these parameters with the level of surface contamination. Among CPs, the raw meat and multi-purpose chopping boards showed the highest criticalities. Although ATP bioluminescence technology cannot substitute traditional microbiological analyses for the determination of microbial load on food contact surfaces, it has proved to be a powerful tool for the real time monitoring of surface cleanliness at mass catering plants, for verify the correct application of SSOP, and hence for their implementation/revision in the case of poor hygiene. PMID:25329534

  17. Balanced Rotating Spray Tank and Pipe Cleaning and Cleanliness Verification System

    NASA Technical Reports Server (NTRS)

    Caimi, Raoul E. B. (Inventor); Thaxton, Eric A. (Inventor)

    1998-01-01

    A system for cleaning and verifying the cleanliness of the interior surfaces of hollow items, such as small bottles, tanks, pipes and tubes, employs a rotating spray head for supplying a gas-liquid cleaning mixture to the item's surface at a supersonic velocity. The spray head incorporates a plurality of nozzles having diverging cross sections so that the incoming gas-liquid mixture is first converged within the spray head and then diverged through the nozzles, thereby accelerating the mixture to a supersonic velocity. In the preferred embodiment, three nozzles are employed; one forwardly facing nozzle at the end of the spray head and two oppositely facing angled nozzles exiting on opposite sides of the spray head which balance each other, and therefore impart no net side load on the spray head. A drive mechanism is provided to rotate the spray head and at the same time move the head back and forth within the item to be cleaned. The drive mechanism acts on a long metal tube to which the spray head is fixed, and thus no moving parts are exposed to the interior surfaces of the items to be cleaned, thereby reducing the risk of contamination.

  18. Qualification of Target Chamber Vacuum Systems Cleanliness using Sol-Gel Coatings

    SciTech Connect

    Miller, P; Stowers, I F; Ertel, J R

    2006-01-03

    This document defines the procedure necessary to qualify the airborne molecular cleanliness (AMC) of vacuum systems (enclosures or large components) that are placed within the National Ignition Facility (NIF) target chamber or are attached to it and communicate with it during vacuum operation. This test is specific to the NIF target chamber because the allowable time dependent rate of rise in the pore filling of a sol-gel coated SAW sensor is based on some nominal change-out time for the disposable debris shields. These debris shields will be sol-gel coated and thus they represent a means of ''pumping'' AMCs from the target chamber. The debris shield pumping rate sets the allowable change in pore filling with time specified in the test procedure. This document describes a two-part procedure that provides both a static measurement of sol-gel pore filling at the end of a 48-hour test period and a dynamic record of pore-filling measured throughout the test period. Successful qualification of a vacuum system requires that both the static and dynamic measurements meet the criteria set forth in Section 7 of this document.

  19. Standard Operating Procedures for Maintaining Cleanliness in a Novel Compact Facility for Breeding SPF Mice

    PubMed Central

    Sakuma, Kenji; Hayashi, Susumu; Otokuni, Keiko; Matsumoto, Izumi; Matsuoka, Hideaki; Saito, Mikako

    2013-01-01

    A compact facility for SPF mice that was not equipped with a large autoclave used disposable mouse cages instead. The SPF clean room was 5.7 × 8.1 × 2.7 m3, with a breeding capacity of 1008 cages (168 cages on each of 6 racks). We evaluated cleanliness in the SPF clean room under the conditions of an occupation rate of 60% to 70% and typically 1 to 3 personnel (maximum, 4 to 6) daily on weekdays. Personnel were taught standard procedures and received training beforehand. During the 15-mo study period, the maximal concentration of airborne particles 0.5 μm or larger was 1.0 × 104 particles/m3 and that of particles 5.0 μm or larger was 5.0 × 102 particles/m3—well below the maximal permissible concentrations of 3.52 × 105 and 2.93 × 103 particles/m3, respectively. During the study period, no mice exhibited clinical symptoms of infection. Testing of 2 representative, overtly healthy mice for 16 pathogens including Staphylococcus aureus, Pseudomonas aeruginosa, and Helicobacter bilis failed to detect any of the target agents. The current study demonstrates the feasibility of the compact facility for breeding SPF mice in the academic environment. PMID:24351759

  20. Absolute Identification by Relative Judgment

    ERIC Educational Resources Information Center

    Stewart, Neil; Brown, Gordon D. A.; Chater, Nick

    2005-01-01

    In unidimensional absolute identification tasks, participants identify stimuli that vary along a single dimension. Performance is surprisingly poor compared with discrimination of the same stimuli. Existing models assume that identification is achieved using long-term representations of absolute magnitudes. The authors propose an alternative…

  1. Be Resolute about Absolute Value

    ERIC Educational Resources Information Center

    Kidd, Margaret L.

    2007-01-01

    This article explores how conceptualization of absolute value can start long before it is introduced. The manner in which absolute value is introduced to students in middle school has far-reaching consequences for their future mathematical understanding. It begins to lay the foundation for students' understanding of algebra, which can change…

  2. Investigating the intrinsic cleanliness of automated handling designed for EUV mask pod-in-pod systems

    NASA Astrophysics Data System (ADS)

    Brux, O.; van der Walle, P.; van der Donck, J. C. J.; Dress, P.

    2011-11-01

    Extreme Ultraviolet Lithography (EUVL) is the most promising solution for technology nodes 16nm (hp) and below. However, several unique EUV mask challenges must be resolved for a successful launch of the technology into the market. Uncontrolled introduction of particles and/or contamination into the EUV scanner significantly increases the risk for device yield loss and potentially scanner down-time. With the absence of a pellicle to protect the surface of the EUV mask, a zero particle adder regime between final clean and the point-of-exposure is critical for the active areas of the mask. A Dual Pod concept for handling EUV masks had been proposed by the industry as means to minimize the risk of mask contamination during transport and storage. SuSS-HamaTech introduces MaskTrackPro InSync as a fully automated solution for the handling of EUV masks in and out of this Dual Pod System and therefore constitutes an interface between various tools inside the Fab. The intrinsic cleanliness of each individual handling and storage step of the inner shell (EIP) of this Dual Pod and the EUV mask inside the InSync Tool has been investigated to confirm the capability for minimizing the risk of cross-contamination. An Entegris Dual Pod EUV-1000A-A110 has been used for the qualification. The particle detection for the qualification procedure was executed with the TNO's RapidNano Particle Scanner, qualified for particle sizes down to 50nm (PSL equivalent). It has been shown that the target specification of < 2 particles @ 60nm per 25 cycles has been achieved. In case where added particles were measured, the EIP has been identified as a potential root cause for Ni particle generation. Any direct Ni-Al contact has to be avoided to mitigate the risk of material abrasion.

  3. The habitus of hygiene: discourses of cleanliness and infection control in nursing work.

    PubMed

    Brown, Brian; Crawford, Paul; Nerlich, Brigitte; Koteyko, Nelya

    2008-10-01

    This paper reports upon a qualitative interview study of 22 matrons, infection control staff and operating theatre staff who were questioned about their working lives and the role they played in the control of healthcare acquired infections such as MRSA virus in the UK. A theoretical framework drawing upon the work of Bourdieu is deployed as his notion of habitus captures the combination of practical work, physical disposition and ways of looking at the world which are displayed in the interview accounts of labour in the healthcare field. Three themes emerged from the analysis: first, the 'securitization' of healthcare work, concerned with control, supervision, 'making sure' and the management of risk through inspection, audit and the exercise of responsibility; second, the sense of struggle against doctors who were seen to represent a threat to the carefully organized boundaries, through such alleged violations as not washing their hands, wandering between theatre and canteen areas in soiled clothing and thinking the rules did not apply to them; third, in a 'back to basics' theme participants emphasised the fundamentals of what they saw to be nursing work and were concerned with cleanliness and practically based training -- the habitus of hygiene itself. This was formulated in nostalgic terms with reminiscences about basic training earlier in the participants' careers. The preoccupation with hygiene and its 'basic' processes can be seen as a way of managing uncertainty, accumulating a certain kind of symbolic capital and constructing and maintaining boundaries in the healthcare field. It also makes for self-governing, self-exploiting individuals who accrue responsibility to themselves for implementing the 'habitus of hygiene'. PMID:18639965

  4. Toward Excellence in Technology Education

    ERIC Educational Resources Information Center

    LaPorte, James E.

    2008-01-01

    This article presents a text of a speech delivered by the author at the Foundation for Technology Education (FTE) Spirit of Excellence breakfast in Salt Lake City, Utah. In this speech, the author talked about the meaning of excellence. In order to pursue excellence, the author suggested that people in the field of technology education should…

  5. ASBO's Certificate of Excellence Program: 15 years of Professional Excellence.

    ERIC Educational Resources Information Center

    Gatti, Bernard

    1987-01-01

    Presents the history, advantages, and requirements of the Association of School Business Officials' Certificate of Excellence Program. Receiving a Certificate of Excellence provides evidence of the integrity and technical competence of a school system's fiscal administration to the board members and superintendent. (MLF)

  6. Development of Genesis Solar Wind Sample Cleanliness Assessment: Initial Report on Sample 60341 Optical Imagery and Elemental Mapping

    NASA Technical Reports Server (NTRS)

    Gonzalez, C. P.; Goreva, Y. S.; Burnett, D. S.; Woolum, D.; Jurewicz, A. J.; Allton, J. H.; Rodriguez, P. J.; Burkett, P. J.

    2014-01-01

    Since 2005 the Genesis science team has experimented with techniques for removing the contaminant particles and films from the collection surface of the Genesis fragments. A subset of 40 samples have been designated as "cleaning matrix" samples. These are small samples to which various cleaning approaches are applied and then cleanliness is assessed optically, by TRXRF, SEM, ToF-SIMS, XPS, ellipsometry or other means [1-9]. Most of these sam-ples remain available for allocation, with cleanliness assessment data. This assessment allows evaluation of various cleaning techniques and handling or analytical effects. Cleaning techniques investigated by the Genesis community include acid/base etching, acetate replica peels, ion beam, and CO2 snow jet cleaning [10-16]. JSC provides surface cleaning using UV ozone exposure and ultra-pure water (UPW) [17-20]. The UPW rinse is commonly used to clean samples for handling debris between processing by different researchers. Optical microscopic images of the sample taken before and after UPW cleaning show what has been added or removed during the cleaning process.

  7. Absolute transition probabilities of phosphorus.

    NASA Technical Reports Server (NTRS)

    Miller, M. H.; Roig, R. A.; Bengtson, R. D.

    1971-01-01

    Use of a gas-driven shock tube to measure the absolute strengths of 21 P I lines and 126 P II lines (from 3300 to 6900 A). Accuracy for prominent, isolated neutral and ionic lines is estimated to be 28 to 40% and 18 to 30%, respectively. The data and the corresponding theoretical predictions are examined for conformity with the sum rules.-

  8. Grassroots Excellence: Problems and Progress.

    ERIC Educational Resources Information Center

    Hansen, Kenneth H.

    The educational "excellence" movement is hindered by inconsistencies between goals and action and by difficulties in translating national and state goals into local policy; nonetheless, progress has occurred. Examples of "voodoo excellence," in which proposed policies will likely work against their stated objectives, are widespread. While…

  9. Associations between Active Trachoma and Community Intervention with Antibiotics, Facial Cleanliness, and Environmental Improvement (A,F,E)

    PubMed Central

    Ngondi, Jeremiah; Matthews, Fiona; Reacher, Mark; Baba, Samson; Brayne, Carol; Emerson, Paul

    2008-01-01

    Background Surgery, Antibiotics, Facial cleanliness and Environmental improvement (SAFE) are advocated by the World Health Organization (WHO) for trachoma control. However, few studies have evaluated the complete SAFE strategy, and of these, none have investigated the associations of Antibiotics, Facial cleanliness, and Environmental improvement (A,F,E) interventions and active trachoma. We aimed to investigate associations between active trachoma and A,F,E interventions in communities in Southern Sudan. Methods and Findings Surveys were undertaken in four districts after 3 years of implementation of the SAFE strategy. Children aged 1–9 years were examined for trachoma and uptake of SAFE assessed through interviews and observations. Using ordinal logistic regression, associations between signs of active trachoma and A,F,E interventions were explored. Trachomatous inflammation-intense (TI) was considered more severe than trachomatous inflammation-follicular (TF). A total of 1,712 children from 25 clusters (villages) were included in the analysis. Overall uptake of A,F,E interventions was: 53.0% of the eligible children had received at least one treatment with azithromycin; 62.4% children had a clean face on examination; 72.5% households reported washing faces of children two or more times a day; 73.1% households had received health education; 44.4% of households had water accessible within 30 minutes; and 6.3% households had pit latrines. Adjusting for age, sex, and district baseline prevalence of active trachoma, factors independently associated with reduced odds of a more severe active trachoma sign were: receiving three treatments with azithromycin (odds ratio [OR] = 0.1; 95% confidence interval [CI] 0.0–0.4); clean face (OR = 0.3; 95% CI 0.2–0.4); washing faces of children three or more times daily (OR = 0.4; 95% CI 0.3–0.7); and presence and use of a pit latrine in the household (OR = 0.4; 95% CI 0.2–0.9). Conclusion Analysis of

  10. Influence of Ultrasonic Irrigation and Chloroform on Cleanliness of Dentinal Tubules During Endodontic Retreatment-An Invitro SEM Study

    PubMed Central

    Singhal, Anurag; Gurtu, Anuraag; Vinayak, Vineet

    2015-01-01

    Background Ultrasonic irrigation has been proved for its remarkable cleaning efficiency in the field of endodontics. But its role in endodontic re-treatment has been understated. There is not much data available to understand the effect of ultrasonic irrigation for the evaluation of cleanliness of dentinal tubules when it is used with or without chloroform, a gutta percha solvent during endodontic retreatment. Aim To compare the influence of ultrasonic irrigation with syringe irrigation on cleanliness of dentinal tubules after gutta perch removal for endodontic retreatment with or without the use of chloroform a gutta percha solvent using scanning electron microscope (SEM). Materials and Methods Freshly extracted 45 human mandibular premolar teeth for periodontal and orthodontic reasons were taken and were occlusally adjusted to a working length of 19 mm. The root canals of all teeth were prepared chemo mechanically to a master apical file size 40 and were divided in various groups. In Group 1 (n = 5; control group), the canals remained unfilled. In Groups 2 and 3 (n = 20 each), the canals were filled using lateral compaction with gutta-percha and AH plus sealer, removal of root fillings was undertaken after 2 weeks using Gates Glidden drills and H files without chloroform in Group 2 and with chloroform in group 3. The specimen of Group 2 and 3 were further divided into two subgroups I and II (n=10). In subgroup I, irrigation was done using side vented needles and sodium hypochlorite. In subgroup II irrigation was done using passive ultrasonic irrigation with sodium hypochlorite. Thereafter, the roots were split and the sections were observed under SEM. The number of occluded dentinal tubules /total number of dentinal tubules were calculated for the coronal, middle and apical third of each root half. Statistical analysis was performed using one-way ANOVA followed by Tukey’s test using standardized technique. Result Results indicated that the cleanest dentinal

  11. Optomechanics for absolute rotation detection

    NASA Astrophysics Data System (ADS)

    Davuluri, Sankar

    2016-07-01

    In this article, we present an application of optomechanical cavity for the absolute rotation detection. The optomechanical cavity is arranged in a Michelson interferometer in such a way that the classical centrifugal force due to rotation changes the length of the optomechanical cavity. The change in the cavity length induces a shift in the frequency of the cavity mode. The phase shift corresponding to the frequency shift in the cavity mode is measured at the interferometer output to estimate the angular velocity of absolute rotation. We derived an analytic expression to estimate the minimum detectable rotation rate in our scheme for a given optomechanical cavity. Temperature dependence of the rotation detection sensitivity is studied.

  12. The Absolute Spectrum Polarimeter (ASP)

    NASA Technical Reports Server (NTRS)

    Kogut, A. J.

    2010-01-01

    The Absolute Spectrum Polarimeter (ASP) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from 30 GHz to 5 THz. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much greater than 1O(raised to the power of { -3}) and Compton distortion y < 10 (raised to the power of{-6}). We describe the ASP instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

  13. Absolute calibration of optical flats

    DOEpatents

    Sommargren, Gary E.

    2005-04-05

    The invention uses the phase shifting diffraction interferometer (PSDI) to provide a true point-by-point measurement of absolute flatness over the surface of optical flats. Beams exiting the fiber optics in a PSDI have perfect spherical wavefronts. The measurement beam is reflected from the optical flat and passed through an auxiliary optic to then be combined with the reference beam on a CCD. The combined beams include phase errors due to both the optic under test and the auxiliary optic. Standard phase extraction algorithms are used to calculate this combined phase error. The optical flat is then removed from the system and the measurement fiber is moved to recombine the two beams. The newly combined beams include only the phase errors due to the auxiliary optic. When the second phase measurement is subtracted from the first phase measurement, the absolute phase error of the optical flat is obtained.

  14. Obstacles to the ‘cleanliness of our race’: HIV, reproductive risk, stratified reproduction, and population quality in Hanoi, Vietnam

    PubMed Central

    Hong, Khuat Thu; Nhan, Vu Thi Thanh; Thao, Nguyen Thi Phuong; Hirsch, Jennifer S.

    2013-01-01

    This paper focuses on the interactions between medical professionals in Hanoi, Vietnam and their HIV-positive patients who desire children. Drawing on ethnographic research, we argue that despite ongoing state and civil society efforts to reduce discrimination against people living with HIV (PLHIV), doctors do stigmatize patients who choose to reproduce, even if the patients are found to have carefully considered all associated risks. While the effects of the Social Evils Campaign linger, the doctors’ prejudicial stance towards PLHIV’s reproductive desires and risks also reflects the messages communicated by the more recent governmental campaign on Population Quality. The result of this stigmatization is a stratification of reproduction among the Vietnamese citizenry whereby PLHIV are considered obstacles to ‘the cleanliness of the race’. PMID:25378810

  15. The AFGL absolute gravity program

    NASA Technical Reports Server (NTRS)

    Hammond, J. A.; Iliff, R. L.

    1978-01-01

    A brief discussion of the AFGL's (Air Force Geophysics Laboratory) program in absolute gravity is presented. Support of outside work and in-house studies relating to gravity instrumentation are discussed. A description of the current transportable system is included and the latest results are presented. These results show good agreement with measurements at the AFGL site by an Italian system. The accuracy obtained by the transportable apparatus is better than 0.1 microns sq sec 10 microgal and agreement with previous measurements is within the combined uncertainties of the measurements.

  16. A Path to Academic Excellence

    ERIC Educational Resources Information Center

    Grizzard, Clare; Woerner, Georgia K.

    2010-01-01

    Educators in Roland Park Elementary/Middle School in Baltimore recognize the essential role that the arts play in education. This K-8 urban public school, which serves a highly diverse population, focuses on academic excellence and high standards for students and faculty. They believe that teaching "in and through the arts" helps to achieve those…

  17. Partnership for Excellence, Fall 2000.

    ERIC Educational Resources Information Center

    Cartnal, Ryan; Hagen, Pete

    Cuesta College (California) students are exceeding goals for AA/AS degrees and certificates, along with basic skills, vocational and occupational course completions. Students have shown excellent progress for goals with transfer preparedness and have shown improvement in combined California State University (CSU) and University of California (UC)…

  18. Using Excel in the Classroom.

    ERIC Educational Resources Information Center

    Summerville, Jennifer; Morrow, Jean; Howell, Dusti

    Microsoft Excel is a sophisticated and flexible reporting, planning, and presentation tool that teachers can use effectively for curriculum prep, class projects, budget planning and reporting, and even as a database. This book, a how-to guide for teachers at all grade levels, provides information on the fundamentals of creating powerful…

  19. Directions to Excellence in Education.

    ERIC Educational Resources Information Center

    Dochterman, Clifford L.; Beshoar, Barron B.

    This monograph is directed toward policy makers, parents, students, educational leaders, teachers, taxpayers and society as a whole, aiming at their involvement and the attainment of excellence in education. People living in a rapidly changing society have many expectations for education, among which are the teaching of moral and ethical values,…

  20. On Excellence: Craftsmanship and Leadership

    ERIC Educational Resources Information Center

    Merrill, Chris

    2013-01-01

    At a presentation from the Maley "Spirit of Excellence" Breakfast in Columbus, OH, March 2013, the author shares comments about craftsmanship and leadership as they relate to technology and engineering education. Students need more experience getting their hands dirty troubleshooting, researching and developing, inventing and innovating,…

  1. Implementing the Reading Excellence Act.

    ERIC Educational Resources Information Center

    Lacy, Laurie; Dole, Janice; Donaldson, Becky; Donaldson, Brady

    This slide presentation outlines one state's (Utah) version of implementation of a model for literacy learning under the Reading Excellence Act (REA). According to the presentation, the model is called "The Utah Reads K-3 Literacy Model." The presentation is divided into the following sections: Utah's Vision: What We've Learned So Far; One…

  2. Cosmology with negative absolute temperatures

    NASA Astrophysics Data System (ADS)

    Vieira, J. P. P.; Byrnes, Christian T.; Lewis, Antony

    2016-08-01

    Negative absolute temperatures (NAT) are an exotic thermodynamical consequence of quantum physics which has been known since the 1950's (having been achieved in the lab on a number of occasions). Recently, the work of Braun et al. [1] has rekindled interest in negative temperatures and hinted at a possibility of using NAT systems in the lab as dark energy analogues. This paper goes one step further, looking into the cosmological consequences of the existence of a NAT component in the Universe. NAT-dominated expanding Universes experience a borderline phantom expansion (w < ‑1) with no Big Rip, and their contracting counterparts are forced to bounce after the energy density becomes sufficiently large. Both scenarios might be used to solve horizon and flatness problems analogously to standard inflation and bouncing cosmologies. We discuss the difficulties in obtaining and ending a NAT-dominated epoch, and possible ways of obtaining density perturbations with an acceptable spectrum.

  3. Excellence in Ophthalmology: Continuous Certification.

    PubMed

    Siatkowski, R Michael

    2016-09-01

    Over the course of a century, American medical specialty boards including the American Board of Ophthalmology (ABO) have developed significant expertise in assessing physician competence on completion of postgraduate training and, more recently, in defining appropriate criteria for continuous learning and quality improvement in practicing physicians. This article explores why maintaining career-long excellence is an evolving challenge, but one that is at the heart of the ABO's mission to protect the public by improving patient care. PMID:27549998

  4. Advances in the production and use of steel with improved internal cleanliness. ASTM special technical publication 1361

    SciTech Connect

    Mahaney, J.K. Jr.

    1999-07-01

    From earliest times, the presence of nonmetallic inclusion has been a major source of problems and failures. Failures due to inclusions have been seen in major structures and boilers as well as the inability to successfully form material into usable shapes and parts. The conference sought to determine the status of the state of the art of inclusion identification and prevention, as well as the relative status of different parts of the industry in the attempt to produce material with improved internal cleanliness. The papers presented in this book cover areas from bearing steels to castings. The various authors clearly show that level of inclusion identification and control through processing improvements is greatly dependent upon the sector of the industry. The level of inclusions desired in bearings is several orders of magnitude from the majority of the casting industry. At the same time, manufacturing methods such as continuous casting and other tonnage industry methods are not available in the discrete steel and iron casting segments of the metal melting industry. The papers in the Special Technical Publication show the state of the art in inclusion identification, prevention, and understanding of the deleterious effects of those inclusions. Products covered include bearing steels, high-strength plates, steel castings, stainless steel medical implants, and test methods to determine the presence and effect of nonmetallic inclusions in the steel products. The papers emphasize the effect on the products rather than manufacturing methods.

  5. Improving HST Pointing & Absolute Astrometry

    NASA Astrophysics Data System (ADS)

    Lallo, Matthew; Nelan, E.; Kimmer, E.; Cox, C.; Casertano, S.

    2007-05-01

    Accurate absolute astrometry is becoming increasingly important in an era of multi-mission archives and virtual observatories. Hubble Space Telescope's (HST's) Guidestar Catalog II (GSC2) has reduced coordinate error to around 0.25 arcsecond, a factor 2 or more compared with GSC1. With this reduced catalog error, special attention must be given to calibrate and maintain the Fine Guidance Sensors (FGSs) and Science Instruments (SIs) alignments in HST to a level well below this in order to ensure that the accuracy of science product's astrometry keywords and target positioning are limited only by the catalog errors. After HST Servicing Mission 4, such calibrations' improvement in "blind" pointing accuracy will allow for more efficient COS acquisitions. Multiple SIs and FGSs each have their own footprints in the spatially shared HST focal plane. It is the small changes over time in primarily the whole-body positions & orientations of these instruments & guiders relative to one another that is addressed by this work. We describe the HST Cycle 15 program CAL/OTA 11021 which, along with future variants of it, determines and maintains positions and orientations of the SIs and FGSs to better than 50 milli- arcseconds and 0.04 to 0.004 degrees of roll, putting errors associated with the alignment sufficiently below GSC2 errors. We present recent alignment results and assess their errors, illustrate trends, and describe where and how the observer sees benefit from these calibrations when using HST.

  6. Absolute oral bioavailability of ciprofloxacin.

    PubMed

    Drusano, G L; Standiford, H C; Plaisance, K; Forrest, A; Leslie, J; Caldwell, J

    1986-09-01

    We evaluated the absolute bioavailability of ciprofloxacin, a new quinoline carboxylic acid, in 12 healthy male volunteers. Doses of 200 mg were given to each of the volunteers in a randomized, crossover manner 1 week apart orally and as a 10-min intravenous infusion. Half-lives (mean +/- standard deviation) for the intravenous and oral administration arms were 4.2 +/- 0.77 and 4.11 +/- 0.74 h, respectively. The serum clearance rate averaged 28.5 +/- 4.7 liters/h per 1.73 m2 for the intravenous administration arm. The renal clearance rate accounted for approximately 60% of the corresponding serum clearance rate and was 16.9 +/- 3.0 liters/h per 1.73 m2 for the intravenous arm and 17.0 +/- 2.86 liters/h per 1.73 m2 for the oral administration arm. Absorption was rapid, with peak concentrations in serum occurring at 0.71 +/- 0.15 h. Bioavailability, defined as the ratio of the area under the curve from 0 h to infinity for the oral to the intravenous dose, was 69 +/- 7%. We conclude that ciprofloxacin is rapidly absorbed and reliably bioavailable in these healthy volunteers. Further studies with ciprofloxacin should be undertaken in target patient populations under actual clinical circumstances. PMID:3777908

  7. Absolute Instability in Coupled-Cavity TWTs

    NASA Astrophysics Data System (ADS)

    Hung, D. M. H.; Rittersdorf, I. M.; Zhang, Peng; Lau, Y. Y.; Simon, D. H.; Gilgenbach, R. M.; Chernin, D.; Antonsen, T. M., Jr.

    2014-10-01

    This paper will present results of our analysis of absolute instability in a coupled-cavity traveling wave tube (TWT). The structure mode at the lower and upper band edges are respectively approximated by a hyperbola in the (omega, k) plane. When the Briggs-Bers criterion is applied, a threshold current for onset of absolute instability is observed at the upper band edge, but not the lower band edge. The nonexistence of absolute instability at the lower band edge is mathematically similar to the nonexistence of absolute instability that we recently demonstrated for a dielectric TWT. The existence of absolute instability at the upper band edge is mathematically similar to the existence of absolute instability in a gyroton traveling wave amplifier. These interesting observations will be discussed, and the practical implications will be explored. This work was supported by AFOSR, ONR, and L-3 Communications Electron Devices.

  8. Absolute negative mobility of interacting Brownian particles

    NASA Astrophysics Data System (ADS)

    Ou, Ya-li; Hu, Cai-tian; Wu, Jian-chun; Ai, Bao-quan

    2015-12-01

    Transport of interacting Brownian particles in a periodic potential is investigated in the presence of an ac force and a dc force. From Brownian dynamic simulations, we find that both the interaction between particles and the thermal fluctuations play key roles in the absolute negative mobility (the particle noisily moves backwards against a small constant bias). When no the interaction acts, there is only one region where the absolute negative mobility occurs. In the presence of the interaction, the absolute negative mobility may appear in multiple regions. The weak interaction can be helpful for the absolute negative mobility, while the strong interaction has a destructive impact on it.

  9. Centers of Excellence: A Catalogue

    NASA Technical Reports Server (NTRS)

    Phelps, Paul B. (Compiler)

    1988-01-01

    This report summarizes information on State-sponsored 'Centers of Excellence' gathered during a survey of State programs in the Fall of 1987. For the purposes of this catalog, 'Centers of Excellence' refers to organizations or activities with the following characteristics: institutionalized, focused, cooperative Research and Development (R&D) programs; supported in part by State governments, in addition to universities, industry and (in some cases) Federal agencies; performed by teams that may include both industry and university employees; and concentrated on relatively specific R&D agendas, usually with near term commercial or governmental applicability. Most of these activities involve state-of-the-art advancement of new technologies under conditions leading to early practical applications. Not included in this catalog are project-level matching grant programs. The principal purpose of this catalog is to help NASA program management, at all levels. to identify and where appropriate, to initiate relationships with other technology-developing organizations. These State-sponsored programs should be of particular interest, because: they present an opportunity to leverage NASA's R&D investments; they are concentrated at the frontier, yet have a concern for practical applications; and they involve industrial participation under conditions that increase the probability of prompt, widespread dissemination in the form of new or enhanced commercial products, processes, or services.

  10. College Astronomy Teaching Excellence Workshops

    NASA Astrophysics Data System (ADS)

    Slater, T. F.; Bennett, M.; Greene, W. M.; Pompea, S.; Prather, E. E.

    2003-12-01

    As part of the education and public outreach efforts of the NASA JPL Navigator, SIRTF Mission and the Astronomical Society of the Pacific, astronomy educators affiliated with the Conceptual Astronomy and Physics Education Research (CAPER) Team at the University of Arizona are conducting a series of two- and three-day teaching excellence workshops for college faculty. These workshops are being held in conjunction with professional society meetings, such as the American Astronomical Society and the American Association of Physics Teachers, and through the infrastructure of the National Science Foundation's Summer Chautauqua Workshop program. This three-day, interactive teaching excellence workshop focuses on dilemmas astronomy teachers face and develop practical solutions for the troubling issues in curriculum, instruction, and assessment. After reviewing the latest research about how students learn, participants define and set measurable student learning goals and objectives for students in their astronomy courses and construct effective course syllabi reflecting the ASTRO 101 goals publicized by the AAS. To improve instruction, participants learn how to create productive learning environments by using interactive lectures, peer instruction, engaging demonstrations, collaborative groups, tutorials, computer-based laboratories, and observational projects. Participants also learn how to write more effective multiple-choice tests and implement authentic assessment strategies including portfolio assessment, performance tasks, and concept maps. Texts provided at the workshop are: (i) Learner-Centered Astronomy Teaching, Slater and Adams, Prentice Hall, 2002; (ii) Great Ideas for Teaching Astronomy, Pompea, Brooks Cole, 2000; and (iii) Lecture-Tutorials for Introductory Astronomy, Adams, Prather, & Slater, Prentice Hall, 2002.

  11. Excellence and Education: Rhetoric and Reality

    ERIC Educational Resources Information Center

    Gillies, Donald

    2007-01-01

    "Excellence" has been a prevalent term in New Labour rhetoric on education, most notably in the stated goal of "excellence for all" in education. Despite that, the meaning of the term has remained imprecise, and the implications of universal excellence unclear. In this paper, three distinct definitions of excellence are identified and the…

  12. Inequalities, Absolute Value, and Logical Connectives.

    ERIC Educational Resources Information Center

    Parish, Charles R.

    1992-01-01

    Presents an approach to the concept of absolute value that alleviates students' problems with the traditional definition and the use of logical connectives in solving related problems. Uses a model that maps numbers from a horizontal number line to a vertical ray originating from the origin. Provides examples solving absolute value equations and…

  13. Absolute optical metrology : nanometers to kilometers

    NASA Technical Reports Server (NTRS)

    Dubovitsky, Serge; Lay, O. P.; Peters, R. D.; Liebe, C. C.

    2005-01-01

    We provide and overview of the developments in the field of high-accuracy absolute optical metrology with emphasis on space-based applications. Specific work on the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor is described along with novel applications of the sensor.

  14. Monolithically integrated absolute frequency comb laser system

    DOEpatents

    Wanke, Michael C.

    2016-07-12

    Rather than down-convert optical frequencies, a QCL laser system directly generates a THz frequency comb in a compact monolithically integrated chip that can be locked to an absolute frequency without the need of a frequency-comb synthesizer. The monolithic, absolute frequency comb can provide a THz frequency reference and tool for high-resolution broad band spectroscopy.

  15. Introducing the Mean Absolute Deviation "Effect" Size

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  16. Investigating Absolute Value: A Real World Application

    ERIC Educational Resources Information Center

    Kidd, Margaret; Pagni, David

    2009-01-01

    Making connections between various representations is important in mathematics. In this article, the authors discuss the numeric, algebraic, and graphical representations of sums of absolute values of linear functions. The initial explanations are accessible to all students who have experience graphing and who understand that absolute value simply…

  17. Absolute Income, Relative Income, and Happiness

    ERIC Educational Resources Information Center

    Ball, Richard; Chernova, Kateryna

    2008-01-01

    This paper uses data from the World Values Survey to investigate how an individual's self-reported happiness is related to (i) the level of her income in absolute terms, and (ii) the level of her income relative to other people in her country. The main findings are that (i) both absolute and relative income are positively and significantly…

  18. Animal health and welfare planning improves udder health and cleanliness but not leg health in Austrian dairy herds.

    PubMed

    Tremetsberger, Lukas; Leeb, Christine; Winckler, Christoph

    2015-10-01

    Animal health and welfare planning is considered an important tool for herd management; however, its effectiveness is less well known. The aim of this study was to conduct animal health and welfare planning on 34 Austrian dairy farms and to evaluate changes in health and welfare after 1 yr. After an initial assessment using the Welfare Quality protocol (Welfare Quality Consortium, Lelystad, the Netherlands), results were reported back to the farmers. Health and welfare area(s) in which both the farmer and the researcher regarded improvement as important were discussed. Management practices and husbandry measures were chosen according to the respective farm situation. One year after interventions had been initiated, farms were reassessed, and the degree of implementation of improvement measures was recorded. The average implementation rate was 57% and thus relatively high when compared with other studies. High degrees of implementation were achieved related to cleanliness and udder health, at 77 and 63%, respectively. Intervention measures addressing udder health were mostly easy to incorporate in the daily routine and led to a reduced somatic cell score, whereas this score increased in herds without implementation of measures. The decrease in cows with dirty teats was more pronounced when measures were implemented compared with control farms. The implementation rate regarding leg health (46%) was comparably low in the present study, and leg health did not improve even when measures were implemented. Lying comfort, social behavior, and human-animal relationship did not require interventions and were therefore seldom chosen by farmers as part of health and welfare plans. In conclusion, the structured, participatory process of animal health and welfare planning appears to be a promising way to improve at least some animal health and welfare issues. PMID:26233459

  19. (Center of excellence: Microlaser microscope)

    SciTech Connect

    Webb, R.H.

    1992-01-01

    This Center-of-Excellence grant has two components: development of an imaging system based on microlaser arrays forms a central project among a group of laser diagnostic and therapeutic efforts primarily funded outside the grant. In these first 8 months we have set up the Microlaser Microscope using small microlaser arrays. We have emphasized the basics of microlaser handling and electronic addressing and the optics of the microscope. Details of electronics and optics given here will be used in the larger arrays which should be available soon. After a description of the central Microlaser Microscope project, we touch briefly on the other projects of the Center, which have been outstandingly fruitful this year. Publications are necessarily concerned with the smaller projects, since the Microlaser Microscope is in its early stages.

  20. Center of excellence: Microlaser microscope

    NASA Astrophysics Data System (ADS)

    Webb, R. H.

    This Center-of-Excellence grant has two components: development of an imaging system based on microlaser arrays forms a central project among a group of laser diagnostic and therapeutic efforts primarily funded outside the grant. In these first 8 months we have set up the Microlaser Microscope using small microlaser arrays. We have emphasized the basics of microlaser handling and electronic addressing and the optics of the microscope. Details of electronics and optics given here will be used in the larger arrays which should be available soon. After a description of the central Microlaser Microscope project, we touch briefly on the other projects of the Center, which have been outstandingly fruitful this year. Publications are necessarily concerned with the smaller projects, since the Microlaser Microscope is in its early stages.

  1. Absolute instability of the Gaussian wake profile

    NASA Technical Reports Server (NTRS)

    Hultgren, Lennart S.; Aggarwal, Arun K.

    1987-01-01

    Linear parallel-flow stability theory has been used to investigate the effect of viscosity on the local absolute instability of a family of wake profiles with a Gaussian velocity distribution. The type of local instability, i.e., convective or absolute, is determined by the location of a branch-point singularity with zero group velocity of the complex dispersion relation for the instability waves. The effects of viscosity were found to be weak for values of the wake Reynolds number, based on the center-line velocity defect and the wake half-width, larger than about 400. Absolute instability occurs only for sufficiently large values of the center-line wake defect. The critical value of this parameter increases with decreasing wake Reynolds number, thereby indicating a shrinking region of absolute instability with decreasing wake Reynolds number. If backflow is not allowed, absolute instability does not occur for wake Reynolds numbers smaller than about 38.

  2. Absolute far-ultraviolet spectrophotometry of hot subluminous stars from Voyager

    SciTech Connect

    Holberg, J.B.; Ali, B.; Carone, T.E.; Polidan, R.S. NASA, Goddard Space Flight Center, Greenbelt, MD )

    1991-07-01

    Observations, obtained with the Voyager ultraviolet spectrometers, are presented of absolute fluxes for two well-known hot subluminous stars: BD + 28 deg 4211, an sdO, and G191 - B2B, a hot DA white dwarf. Complete absolute energy distributions for these two stars, from the Lyman limit at 912 A to 1 micron, are given. For BD + 28 deg 4211, a single power law closely represents the entire observed energy distribution. For G191 - B2B, a pure hydrogen model atmosphere provides an excellent match to the entire absolute energy distribution. Voyager absolute fluxes are discussed in relation to those reported from various sounding rocket experiments, including a recent rocket observation of BD + 28 deg 4211. 43 refs.

  3. Absolute optical instruments without spherical symmetry

    NASA Astrophysics Data System (ADS)

    Tyc, Tomáš; Dao, H. L.; Danner, Aaron J.

    2015-11-01

    Until now, the known set of absolute optical instruments has been limited to those containing high levels of symmetry. Here, we demonstrate a method of mathematically constructing refractive index profiles that result in asymmetric absolute optical instruments. The method is based on the analogy between geometrical optics and classical mechanics and employs Lagrangians that separate in Cartesian coordinates. In addition, our method can be used to construct the index profiles of most previously known absolute optical instruments, as well as infinitely many different ones.

  4. Absolute magnitudes of trans-neptunian objects

    NASA Astrophysics Data System (ADS)

    Duffard, R.; Alvarez-candal, A.; Pinilla-Alonso, N.; Ortiz, J. L.; Morales, N.; Santos-Sanz, P.; Thirouin, A.

    2015-10-01

    Accurate measurements of diameters of trans- Neptunian objects are extremely complicated to obtain. Radiomatric techniques applied to thermal measurements can provide good results, but precise absolute magnitudes are needed to constrain diameters and albedos. Our objective is to measure accurate absolute magnitudes for a sample of trans- Neptunian objects, many of which have been observed, and modelled, by the "TNOs are cool" team, one of Herschel Space Observatory key projects grantes with ~ 400 hours of observing time. We observed 56 objects in filters V and R, if possible. These data, along with data available in the literature, was used to obtain phase curves and to measure absolute magnitudes by assuming a linear trend of the phase curves and considering magnitude variability due to rotational light-curve. In total we obtained 234 new magnitudes for the 56 objects, 6 of them with no reported previous measurements. Including the data from the literature we report a total of 109 absolute magnitudes.

  5. A New Gimmick for Assigning Absolute Configuration.

    ERIC Educational Resources Information Center

    Ayorinde, F. O.

    1983-01-01

    A five-step procedure is provided to help students in making the assignment absolute configuration less bothersome. Examples for both single (2-butanol) and multi-chiral carbon (3-chloro-2-butanol) molecules are included. (JN)

  6. On Excellence--Illustrated through Four Exemplars

    ERIC Educational Resources Information Center

    Lewis, Theodore

    2009-01-01

    In this article, the author presents an excerpt from his speech delivered at the Foundation for Technology Education (FTE) Spirit of Excellence Breakfast in Louisville, Kentucky, in Marcy 2009. The author focuses on people whose work reflect excellence and social responsibility. He uses this frame of excellence and social responsibility to reflect…

  7. Teaching Excellence Initiatives: Modalities and Operational Factors

    ERIC Educational Resources Information Center

    Land, Ray; Gordon, George

    2015-01-01

    Teaching excellence is at the centre of national and international higher education policy. The Higher Education Academy (HEA) is a part of the debate to develop a shared understanding of what constitutes teaching excellence and has published research including "Considering Teaching Excellence in Higher Education: 2007-2013" by Dr Vicky…

  8. An Excel macro for generating trilinear plots.

    PubMed

    Shikaze, Steven G; Crowe, Allan S

    2007-01-01

    This computer note describes a method for creating trilinear plots in Microsoft Excel. Macros have been created in MS Excel's internal language: Visual Basic for Applications (VBA). A simple form has been set up to allow the user to input data from an Excel worksheet. The VBA macro is used to convert the triangular data (which consist of three columns of percentage data) into X-Y data. The macro then generates the axes, labels, and grid for the trilinear plot. The X-Y data are plotted as scatter data in Excel. By providing this macro in Excel, users can create trilinear plots in a quick, inexpensive manner. PMID:17257347

  9. Absolute dose calculations for Monte Carlo simulations of radiotherapy beams.

    PubMed

    Popescu, I A; Shaw, C P; Zavgorodni, S F; Beckham, W A

    2005-07-21

    Monte Carlo (MC) simulations have traditionally been used for single field relative comparisons with experimental data or commercial treatment planning systems (TPS). However, clinical treatment plans commonly involve more than one field. Since the contribution of each field must be accurately quantified, multiple field MC simulations are only possible by employing absolute dosimetry. Therefore, we have developed a rigorous calibration method that allows the incorporation of monitor units (MU) in MC simulations. This absolute dosimetry formalism can be easily implemented by any BEAMnrc/DOSXYZnrc user, and applies to any configuration of open and blocked fields, including intensity-modulated radiation therapy (IMRT) plans. Our approach involves the relationship between the dose scored in the monitor ionization chamber of a radiotherapy linear accelerator (linac), the number of initial particles incident on the target, and the field size. We found that for a 10 x 10 cm2 field of a 6 MV photon beam, 1 MU corresponds, in our model, to 8.129 x 10(13) +/- 1.0% electrons incident on the target and a total dose of 20.87 cGy +/- 1.0% in the monitor chambers of the virtual linac. We present an extensive experimental verification of our MC results for open and intensity-modulated fields, including a dynamic 7-field IMRT plan simulated on the CT data sets of a cylindrical phantom and of a Rando anthropomorphic phantom, which were validated by measurements using ionization chambers and thermoluminescent dosimeters (TLD). Our simulation results are in excellent agreement with experiment, with percentage differences of less than 2%, in general, demonstrating the accuracy of our Monte Carlo absolute dose calculations. PMID:16177516

  10. Absolute dose calculations for Monte Carlo simulations of radiotherapy beams

    NASA Astrophysics Data System (ADS)

    Popescu, I. A.; Shaw, C. P.; Zavgorodni, S. F.; Beckham, W. A.

    2005-07-01

    Monte Carlo (MC) simulations have traditionally been used for single field relative comparisons with experimental data or commercial treatment planning systems (TPS). However, clinical treatment plans commonly involve more than one field. Since the contribution of each field must be accurately quantified, multiple field MC simulations are only possible by employing absolute dosimetry. Therefore, we have developed a rigorous calibration method that allows the incorporation of monitor units (MU) in MC simulations. This absolute dosimetry formalism can be easily implemented by any BEAMnrc/DOSXYZnrc user, and applies to any configuration of open and blocked fields, including intensity-modulated radiation therapy (IMRT) plans. Our approach involves the relationship between the dose scored in the monitor ionization chamber of a radiotherapy linear accelerator (linac), the number of initial particles incident on the target, and the field size. We found that for a 10 × 10 cm2 field of a 6 MV photon beam, 1 MU corresponds, in our model, to 8.129 × 1013 ± 1.0% electrons incident on the target and a total dose of 20.87 cGy ± 1.0% in the monitor chambers of the virtual linac. We present an extensive experimental verification of our MC results for open and intensity-modulated fields, including a dynamic 7-field IMRT plan simulated on the CT data sets of a cylindrical phantom and of a Rando anthropomorphic phantom, which were validated by measurements using ionization chambers and thermoluminescent dosimeters (TLD). Our simulation results are in excellent agreement with experiment, with percentage differences of less than 2%, in general, demonstrating the accuracy of our Monte Carlo absolute dose calculations.

  11. Jasminum flexile flower absolute from India--a detailed comparison with three other jasmine absolutes.

    PubMed

    Braun, Norbert A; Kohlenberg, Birgit; Sim, Sherina; Meier, Manfred; Hammerschmidt, Franz-Josef

    2009-09-01

    Jasminum flexile flower absolute from the south of India and the corresponding vacuum headspace (VHS) sample of the absolute were analyzed using GC and GC-MS. Three other commercially available Indian jasmine absolutes from the species: J. sambac, J. officinale subsp. grandiflorum, and J. auriculatum and the respective VHS samples were used for comparison purposes. One hundred and twenty-one compounds were characterized in J. flexile flower absolute, with methyl linolate, benzyl salicylate, benzyl benzoate, (2E,6E)-farnesol, and benzyl acetate as the main constituents. A detailed olfactory evaluation was also performed. PMID:19831037

  12. Effect of the CaO-Al2O3-Based Top Slag on the Cleanliness of Stainless Steel During Secondary Metallurgy

    NASA Astrophysics Data System (ADS)

    Yan, Pengcheng; Huang, Shuigen; Pandelaers, Lieven; Van Dyck, Joris; Guo, Muxing; Blanpain, Bart

    2013-10-01

    The ladle treatment of a 18 pct Cr-9 pct Ni stainless steel, with desulfurization as its main purpose, was simulated on a laboratory scale. The influence of the top slag chemistry on the steel cleanliness was evaluated. A higher steel cleanliness was obtained with an optimized lime-alumina-based slag than with a lime-fluorspar-based slag. The inclusions were found to be mainly in the form of oxysulfide; the alumina content in the inclusions first increased and subsequently showed a slow drop, while the sulfide content decreased during the treatment. The equilibrium between steel and inclusions was found to be more easily reached than that between slag and steel. A slag-steel kinetic model was used to predict the steel chemistry evolution during the treatment. Furthermore, a slag-steel-inclusions interaction kinetic model was developed to calculate the change of alumina content in the inclusions during the ladle treatment. The sulfide content of inclusions was also calculated and compared with the measured values.

  13. Universal Cosmic Absolute and Modern Science

    NASA Astrophysics Data System (ADS)

    Kostro, Ludwik

    The official Sciences, especially all natural sciences, respect in their researches the principle of methodic naturalism i.e. they consider all phenomena as entirely natural and therefore in their scientific explanations they do never adduce or cite supernatural entities and forces. The purpose of this paper is to show that Modern Science has its own self-existent, self-acting, and self-sufficient Natural All-in Being or Omni-Being i.e. the entire Nature as a Whole that justifies the scientific methodic naturalism. Since this Natural All-in Being is one and only It should be considered as the own scientifically justified Natural Absolute of Science and should be called, in my opinion, the Universal Cosmic Absolute of Modern Science. It will be also shown that the Universal Cosmic Absolute is ontologically enormously stratified and is in its ultimate i.e. in its most fundamental stratum trans-reistic and trans-personal. It means that in its basic stratum. It is neither a Thing or a Person although It contains in Itself all things and persons with all other sentient and conscious individuals as well, On the turn of the 20th century the Science has begun to look for a theory of everything, for a final theory, for a master theory. In my opinion the natural Universal Cosmic Absolute will constitute in such a theory the radical all penetrating Ultimate Basic Reality and will substitute step by step the traditional supernatural personal Absolute.

  14. Absolute isotopic abundances of TI in meteorites

    NASA Astrophysics Data System (ADS)

    Niederer, F. R.; Papanastassiou, D. A.; Wasserburg, G. J.

    1985-03-01

    The absolute isotope abundance of Ti has been determined in Ca-Al-rich inclusions from the Allende and Leoville meteorites and in samples of whole meteorites. The absolute Ti isotope abundances differ by a significant mass dependent isotope fractionation transformation from the previously reported abundances, which were normalized for fractionation using 46Ti/48Ti. Therefore, the absolute compositions define distinct nucleosynthetic components from those previously identified or reflect the existence of significant mass dependent isotope fractionation in nature. The authors provide a general formalism for determining the possible isotope compositions of the exotic Ti from the measured composition, for different values of isotope fractionation in nature and for different mixing ratios of the exotic and normal components.

  15. Molecular iodine absolute frequencies. Final report

    SciTech Connect

    Sansonetti, C.J.

    1990-06-25

    Fifty specified lines of {sup 127}I{sub 2} were studied by Doppler-free frequency modulation spectroscopy. For each line the classification of the molecular transition was determined, hyperfine components were identified, and one well-resolved component was selected for precise determination of its absolute frequency. In 3 cases, a nearby alternate line was selected for measurement because no well-resolved component was found for the specified line. Absolute frequency determinations were made with an estimated uncertainty of 1.1 MHz by locking a dye laser to the selected hyperfine component and measuring its wave number with a high-precision Fabry-Perot wavemeter. For each line results of the absolute measurement, the line classification, and a Doppler-free spectrum are given.

  16. Stimulus probability effects in absolute identification.

    PubMed

    Kent, Christopher; Lamberts, Koen

    2016-05-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of presentation probability on both proportion correct and response times. The effects were moderated by the ubiquitous stimulus position effect. The accuracy and response time data were predicted by an exemplar-based model of perceptual cognition (Kent & Lamberts, 2005). The bow in discriminability was also attenuated when presentation probability for middle items was relatively high, an effect that will constrain future model development. The study provides evidence for item-specific learning in absolute identification. Implications for other theories of absolute identification are discussed. (PsycINFO Database Record PMID:26478959

  17. Absolute calibration in vivo measurement systems

    SciTech Connect

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs.

  18. Cold spots in quantum systems far from equilibrium: Local entropies and temperatures near absolute zero

    NASA Astrophysics Data System (ADS)

    Shastry, Abhay; Stafford, Charles A.

    2015-12-01

    We consider a question motivated by the third law of thermodynamics: Can there be a local temperature arbitrarily close to absolute zero in a nonequilibrium quantum system? We consider nanoscale quantum conductors with the source reservoir held at finite temperature and the drain held at or near absolute zero, a problem outside the scope of linear response theory. We obtain local temperatures close to absolute zero when electrons originating from the finite temperature reservoir undergo destructive quantum interference. The local temperature is computed by numerically solving a nonlinear system of equations describing equilibration of a scanning thermoelectric probe with the system, and we obtain excellent agreement with analytic results derived using the Sommerfeld expansion. A local entropy for a nonequilibrium quantum system is introduced and used as a metric quantifying the departure from local equilibrium. It is shown that the local entropy of the system tends to zero when the probe temperature tends to zero, consistent with the third law of thermodynamics.

  19. Precise Measurement of the Absolute Fluorescence Yield

    NASA Astrophysics Data System (ADS)

    Ave, M.; Bohacova, M.; Daumiller, K.; Di Carlo, P.; di Giulio, C.; San Luis, P. Facal; Gonzales, D.; Hojvat, C.; Hörandel, J. R.; Hrabovsky, M.; Iarlori, M.; Keilhauer, B.; Klages, H.; Kleifges, M.; Kuehn, F.; Monasor, M.; Nozka, L.; Palatka, M.; Petrera, S.; Privitera, P.; Ridky, J.; Rizi, V.; D'Orfeuil, B. Rouille; Salamida, F.; Schovanek, P.; Smida, R.; Spinka, H.; Ulrich, A.; Verzi, V.; Williams, C.

    2011-09-01

    We present preliminary results of the absolute yield of fluorescence emission in atmospheric gases. Measurements were performed at the Fermilab Test Beam Facility with a variety of beam particles and gases. Absolute calibration of the fluorescence yield to 5% level was achieved by comparison with two known light sources--the Cherenkov light emitted by the beam particles, and a calibrated nitrogen laser. The uncertainty of the energy scale of current Ultra-High Energy Cosmic Rays experiments will be significantly improved by the AIRFLY measurement.

  20. Absolutely relative or relatively absolute: violations of value invariance in human decision making.

    PubMed

    Teodorescu, Andrei R; Moran, Rani; Usher, Marius

    2016-02-01

    Making decisions based on relative rather than absolute information processing is tied to choice optimality via the accumulation of evidence differences and to canonical neural processing via accumulation of evidence ratios. These theoretical frameworks predict invariance of decision latencies to absolute intensities that maintain differences and ratios, respectively. While information about the absolute values of the choice alternatives is not necessary for choosing the best alternative, it may nevertheless hold valuable information about the context of the decision. To test the sensitivity of human decision making to absolute values, we manipulated the intensities of brightness stimuli pairs while preserving either their differences or their ratios. Although asked to choose the brighter alternative relative to the other, participants responded faster to higher absolute values. Thus, our results provide empirical evidence for human sensitivity to task irrelevant absolute values indicating a hard-wired mechanism that precedes executive control. Computational investigations of several modelling architectures reveal two alternative accounts for this phenomenon, which combine absolute and relative processing. One account involves accumulation of differences with activation dependent processing noise and the other emerges from accumulation of absolute values subject to the temporal dynamics of lateral inhibition. The potential adaptive role of such choice mechanisms is discussed. PMID:26022836

  1. Technical Excellence: A Requirement for Good Engineering

    NASA Technical Reports Server (NTRS)

    Gill, Paul S.; Vaughan, William W.

    2008-01-01

    Technical excellence is a requirement for good engineering. Technical excellence has many different ways of expressing itself within engineering. NASA has initiatives that address the enhancement of the Agency's technical excellence and thrust to maintain the associated high level of performance by the Agency on current programs/projects and as it moves into the Constellation Program and the return to the Moon with plans to visit Mars. This paper addresses some of the key initiatives associated with NASA's technical excellence thrust. Examples are provided to illustrate some results being achieved and plans to enhance these initiatives.

  2. Absolute partial photoionization cross sections of ozone.

    SciTech Connect

    Berkowitz, J.; Chemistry

    2008-04-01

    Despite the current concerns about ozone, absolute partial photoionization cross sections for this molecule in the vacuum ultraviolet (valence) region have been unavailable. By eclectic re-evaluation of old/new data and plausible assumptions, such cross sections have been assembled to fill this void.

  3. Solving Absolute Value Equations Algebraically and Geometrically

    ERIC Educational Resources Information Center

    Shiyuan, Wei

    2005-01-01

    The way in which students can improve their comprehension by understanding the geometrical meaning of algebraic equations or solving algebraic equation geometrically is described. Students can experiment with the conditions of the absolute value equation presented, for an interesting way to form an overall understanding of the concept.

  4. Teaching Absolute Value Inequalities to Mature Students

    ERIC Educational Resources Information Center

    Sierpinska, Anna; Bobos, Georgeana; Pruncut, Andreea

    2011-01-01

    This paper gives an account of a teaching experiment on absolute value inequalities, whose aim was to identify characteristics of an approach that would realize the potential of the topic to develop theoretical thinking in students enrolled in prerequisite mathematics courses at a large, urban North American university. The potential is…

  5. Increasing Capacity: Practice Effects in Absolute Identification

    ERIC Educational Resources Information Center

    Dodds, Pennie; Donkin, Christopher; Brown, Scott D.; Heathcote, Andrew

    2011-01-01

    In most of the long history of the study of absolute identification--since Miller's (1956) seminal article--a severe limit on performance has been observed, and this limit has resisted improvement even by extensive practice. In a startling result, Rouder, Morey, Cowan, and Pfaltz (2004) found substantially improved performance with practice in the…

  6. On Relative and Absolute Conviction in Mathematics

    ERIC Educational Resources Information Center

    Weber, Keith; Mejia-Ramos, Juan Pablo

    2015-01-01

    Conviction is a central construct in mathematics education research on justification and proof. In this paper, we claim that it is important to distinguish between absolute conviction and relative conviction. We argue that researchers in mathematics education frequently have not done so and this has lead to researchers making unwarranted claims…

  7. Absolute Points for Multiple Assignment Problems

    ERIC Educational Resources Information Center

    Adlakha, V.; Kowalski, K.

    2006-01-01

    An algorithm is presented to solve multiple assignment problems in which a cost is incurred only when an assignment is made at a given cell. The proposed method recursively searches for single/group absolute points to identify cells that must be loaded in any optimal solution. Unlike other methods, the first solution is the optimal solution. The…

  8. Nonequilibrium equalities in absolutely irreversible processes

    NASA Astrophysics Data System (ADS)

    Murashita, Yuto; Funo, Ken; Ueda, Masahito

    2015-03-01

    Nonequilibrium equalities have attracted considerable attention in the context of statistical mechanics and information thermodynamics. Integral nonequilibrium equalities reveal an ensemble property of the entropy production σ as = 1 . Although nonequilibrium equalities apply to rather general nonequilibrium situations, they break down in absolutely irreversible processes, where the forward-path probability vanishes and the entropy production diverges. We identify the mathematical origins of this inapplicability as the singularity of probability measure. As a result, we generalize conventional integral nonequilibrium equalities to absolutely irreversible processes as = 1 -λS , where λS is the probability of the singular part defined based on Lebesgue's decomposition theorem. The acquired equality contains two physical quantities related to irreversibility: σ characterizing ordinary irreversibility and λS describing absolute irreversibility. An inequality derived from the obtained equality demonstrates the absolute irreversibility leads to the fundamental lower bound on the entropy production. We demonstrate the validity of the obtained equality for a simple model.

  9. Stimulus Probability Effects in Absolute Identification

    ERIC Educational Resources Information Center

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  10. Precision absolute positional measurement of laser beams.

    PubMed

    Fitzsimons, Ewan D; Bogenstahl, Johanna; Hough, James; Killow, Christian J; Perreur-Lloyd, Michael; Robertson, David I; Ward, Henry

    2013-04-20

    We describe an instrument which, coupled with a suitable coordinate measuring machine, facilitates the absolute measurement within the machine frame of the propagation direction of a millimeter-scale laser beam to an accuracy of around ±4 μm in position and ±20 μrad in angle. PMID:23669658

  11. Florida's Centers of Excellence in English.

    ERIC Educational Resources Information Center

    Deluzain, Edward, Ed.

    1986-01-01

    The eight English language arts programs in the six Florida public schools included among the 150 Centers of Excellence in English selected by the National Council of Teachers of English are described in this focused journal issue. Following an introductory essay by coeditor Edward Deluzain describing the Centers of Excellence selection procedure,…

  12. 76 FR 41233 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-13

    ... Equity and Excellence Commission AGENCY: U.S. Department of Education, Office for Civil Rights. ACTION... meeting of the Equity and Excellence Commission (Commission). The notice also describes the functions of... Center Plaza, 550 12th Street, SW., Washington, DC 20202 in the auditorium (room 10026). FOR...

  13. The Pursuit of Excellence through Education.

    ERIC Educational Resources Information Center

    Ferrari, Michel, Ed.

    In this book theorists and researchers present a range of perspectives on how to promote excellence in education, providing an opportunity for expression to those who stress transformation of educational practice and those who emphasize individual abilities. In part 1, The Individual Pursuit of Excellence, the chapters are: (1) Learning from…

  14. Standards of Excellence in Budget Presentation.

    ERIC Educational Resources Information Center

    Bolton, Denny G.; Harmer, W. Gary

    This guide describes the Meritorious Budget Awards Program recognizing excellence in school system budgeting awarded by the Association of School Business Officials. The award is designed to help school business administrators achieve a high standard of excellence in budget presentations. Chapters provide the expectations and relevant criteria…

  15. Feminist Rhetorical Practices: In Search of Excellence

    ERIC Educational Resources Information Center

    Kirsch, Gesa E.; Royster, Jacqueline J.

    2010-01-01

    In this article, we undertake three critical tasks: First, we delineate major shifts in feminist rhetorical inquiry, thus describing a new and changed landscape of the field. Second, we argue that as feminist rhetorical practices have shifted, so have standards of excellence. To articulate excellence in feminist rhetorical studies, we draw…

  16. 76 FR 27034 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-10

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF EDUCATION Equity and Excellence Commission AGENCY: Office for Civil Rights, U.S. Department of Education. ACTION... upcoming meeting of the Equity and Excellence Commission (Commission). The notice also describes...

  17. 77 FR 67637 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-13

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF EDUCATION Equity and Excellence Commission AGENCY: U.S. Department of Education, Office for Civil Rights. ACTION... Federal Official, Equity and Excellence Commission, U.S. Department of Education, 400 Maryland Avenue...

  18. 77 FR 484 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-05

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF EDUCATION Equity and Excellence Commission AGENCY: Office for Civil Rights, U.S. Department of Education. ACTION..., Equity and Excellence Commission, U.S. Department of Education, 400 Maryland Avenue SW, Washington,...

  19. 76 FR 62394 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-07

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF EDUCATION Equity and Excellence Commission AGENCY: Office for Civil Rights, U.S. Department of Education. ACTION...-coming meeting of the Equity and Excellence Commission (Commission). The notice also describes...

  20. Excellence in Schools of Education: An Oxymoron?

    ERIC Educational Resources Information Center

    Brabeck, Mary M.; Shirley, David

    2003-01-01

    Offers thoughts on why schools, colleges, and departments of education fail to achieve excellence and three premises for achieving same involving building strong partnerships with schools and communities, building an excellent research base, and the preparation of teachers with deep content knowledge, an understanding of child development and…

  1. The global quest for nursing excellence.

    PubMed

    Ferguson, Stephanie L

    2013-11-01

    In this month's column, Stephanie Ferguson, PhD, RN, FAAN, Director, International Council of Nurses' (ICN) Leadership for Change Programme; Facilitator, ICN Global Nursing Leadership Institute; ICN Consultant for Nursing and Health Policy; and World Health Organization Consultant, provides a perspective on the importance of global nursing excellence and highlights the American Nurses Credentialing Center's strategic global quest for nursing excellence. PMID:24153194

  2. Getting the Best out of Excel

    ERIC Educational Resources Information Center

    Heys, Chris

    2008-01-01

    Excel, Microsoft's spreadsheet program, offers several tools which have proven useful in solving some optimization problems that arise in operations research. We will look at two such tools, the Excel modules called Solver and Goal Seek--this after deriving an equation, called the "cash accumulation equation", to be used in conjunction with them.

  3. Using Microsoft Excel to Generate Usage Statistics

    ERIC Educational Resources Information Center

    Spellman, Rosemary

    2011-01-01

    At the Libraries Service Center, statistics are generated on a monthly, quarterly, and yearly basis by using four Microsoft Excel workbooks. These statistics provide information about what materials are being requested and by whom. They also give details about why certain requests may not have been filled. Utilizing Excel allows for a shallower…

  4. School Effectiveness: Profile of School Excellence.

    ERIC Educational Resources Information Center

    Sanders, Jack; And Others

    Based on Larry Hutchins' analysis of the school effectiveness literature, the Profile of School Excellence (PRO-S/E) is a diagnostic tool keyed to 11 instructional and organizational variables which are positively related to effective/excellent schools and which are alterable. The variables are: needs basis; objectives; expectations; roles and…

  5. Excellence through Minimum Essentials and Individual Development.

    ERIC Educational Resources Information Center

    Alexander, William M.

    1986-01-01

    The author states that throughout the past century or more, especially during the twentieth century, the continuing conflict between proponents of the minimum essentials approach to curriculum excellence and those of the individual development approach has been an obstacle to the achievement of excellence. (CT)

  6. Combined Use of Absolute and Differential Seismic Arrival Time Data to Improve Absolute Event Location

    NASA Astrophysics Data System (ADS)

    Myers, S.; Johannesson, G.

    2012-12-01

    Arrival time measurements based on waveform cross correlation are becoming more common as advanced signal processing methods are applied to seismic data archives and real-time data streams. Waveform correlation can precisely measure the time difference between the arrival of two phases, and differential time data can be used to constrain relative location of events. Absolute locations are needed for many applications, which generally requires the use of absolute time data. Current methods for measuring absolute time data are approximately two orders of magnitude less precise than differential time measurements. To exploit the strengths of both absolute and differential time data, we extend our multiple-event location method Bayesloc, which previously used absolute time data only, to include the use of differential time measurements that are based on waveform cross correlation. Fundamentally, Bayesloc is a formulation of the joint probability over all parameters comprising the multiple event location system. The Markov-Chain Monte Carlo method is used to sample from the joint probability distribution given arrival data sets. The differential time component of Bayesloc includes scaling a stochastic estimate of differential time measurement precision based the waveform correlation coefficient for each datum. For a regional-distance synthetic data set with absolute and differential time measurement error of 0.25 seconds and 0.01 second, respectively, epicenter location accuracy is improved from and average of 1.05 km when solely absolute time data are used to 0.28 km when absolute and differential time data are used jointly (73% improvement). The improvement in absolute location accuracy is the result of conditionally limiting absolute location probability regions based on the precise relative position with respect to neighboring events. Bayesloc estimates of data precision are found to be accurate for the synthetic test, with absolute and differential time measurement

  7. Excellence in the Knowledge-Based Economy: From Scientific to Research Excellence

    ERIC Educational Resources Information Center

    Sørensen, Mads P.; Bloch, Carter; Young, Mitchell

    2016-01-01

    In 2013, the European Union (EU) unveiled its new "Composite Indicator for Scientific and Technological Research Excellence." This is not an isolated occurrence; policy-based interest in excellence is growing all over the world. The heightened focus on excellence and, in particular, attempts to define it through quantitative indicators…

  8. Absolute and relative dosimetry for ELIMED

    SciTech Connect

    Cirrone, G. A. P.; Schillaci, F.; Scuderi, V.; Cuttone, G.; Candiano, G.; Musumarra, A.; Pisciotta, P.; Romano, F.; Carpinelli, M.; Presti, D. Lo; Raffaele, L.; Tramontana, A.; Cirio, R.; Sacchi, R.; Monaco, V.; Marchetto, F.; Giordanengo, S.

    2013-07-26

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  9. Probing absolute spin polarization at the nanoscale.

    PubMed

    Eltschka, Matthias; Jäck, Berthold; Assig, Maximilian; Kondrashov, Oleg V; Skvortsov, Mikhail A; Etzkorn, Markus; Ast, Christian R; Kern, Klaus

    2014-12-10

    Probing absolute values of spin polarization at the nanoscale offers insight into the fundamental mechanisms of spin-dependent transport. Employing the Zeeman splitting in superconducting tips (Meservey-Tedrow-Fulde effect), we introduce a novel spin-polarized scanning tunneling microscopy that combines the probing capability of the absolute values of spin polarization with precise control at the atomic scale. We utilize our novel approach to measure the locally resolved spin polarization of magnetic Co nanoislands on Cu(111). We find that the spin polarization is enhanced by 65% when increasing the width of the tunnel barrier by only 2.3 Å due to the different decay of the electron orbitals into vacuum. PMID:25423049

  10. Absolute-magnitude distributions of supernovae

    SciTech Connect

    Richardson, Dean; Wright, John; Jenkins III, Robert L.; Maddox, Larry

    2014-05-01

    The absolute-magnitude distributions of seven supernova (SN) types are presented. The data used here were primarily taken from the Asiago Supernova Catalogue, but were supplemented with additional data. We accounted for both foreground and host-galaxy extinction. A bootstrap method is used to correct the samples for Malmquist bias. Separately, we generate volume-limited samples, restricted to events within 100 Mpc. We find that the superluminous events (M{sub B} < –21) make up only about 0.1% of all SNe in the bias-corrected sample. The subluminous events (M{sub B} > –15) make up about 3%. The normal Ia distribution was the brightest with a mean absolute blue magnitude of –19.25. The IIP distribution was the dimmest at –16.75.

  11. Absolute radiometry and the solar constant

    NASA Technical Reports Server (NTRS)

    Willson, R. C.

    1974-01-01

    A series of active cavity radiometers (ACRs) are described which have been developed as standard detectors for the accurate measurement of irradiance in absolute units. It is noted that the ACR is an electrical substitution calorimeter, is designed for automatic remote operation in any environment, and can make irradiance measurements in the range from low-level IR fluxes up to 30 solar constants with small absolute uncertainty. The instrument operates in a differential mode by chopping the radiant flux to be measured at a slow rate, and irradiance is determined from two electrical power measurements together with the instrumental constant. Results are reported for measurements of the solar constant with two types of ACRs. The more accurate measurement yielded a value of 136.6 plus or minus 0.7 mW/sq cm (1.958 plus or minus 0.010 cal/sq cm per min).

  12. Asteroid absolute magnitudes and slope parameters

    NASA Technical Reports Server (NTRS)

    Tedesco, Edward F.

    1991-01-01

    A new listing of absolute magnitudes (H) and slope parameters (G) has been created and published in the Minor Planet Circulars; this same listing will appear in the 1992 Ephemerides of Minor Planets. Unlike previous listings, the values of the current list were derived from fits of data at the V band. All observations were reduced in the same fashion using, where appropriate, a single basis default value of 0.15 for the slope parameter. Distances and phase angles were computed for each observation. The data for 113 asteroids was of sufficiently high quality to permit derivation of their H and G. These improved absolute magnitudes and slope parameters will be used to deduce the most reliable bias-corrected asteroid size-frequency distribution yet made.

  13. Absolute calibration of TFTR helium proportional counters

    SciTech Connect

    Strachan, J.D.; Diesso, M.; Jassby, D.; Johnson, L.; McCauley, S.; Munsat, T.; Roquemore, A.L.; Barnes, C.W. |; Loughlin, M. |

    1995-06-01

    The TFTR helium proportional counters are located in the central five (5) channels of the TFTR multichannel neutron collimator. These detectors were absolutely calibrated using a 14 MeV neutron generator positioned at the horizontal midplane of the TFTR vacuum vessel. The neutron generator position was scanned in centimeter steps to determine the collimator aperture width to 14 MeV neutrons and the absolute sensitivity of each channel. Neutron profiles were measured for TFTR plasmas with time resolution between 5 msec and 50 msec depending upon count rates. The He detectors were used to measure the burnup of 1 MeV tritons in deuterium plasmas, the transport of tritium in trace tritium experiments, and the residual tritium levels in plasmas following 50:50 DT experiments.

  14. Absolute enantioselective separation: optical activity ex machina.

    PubMed

    Bielski, Roman; Tencer, Michal

    2005-11-01

    The paper describes methodology of using three independent macroscopic factors affecting molecular orientation to accomplish separation of a racemic mixture without the presence of any other chiral compounds, i. e., absolute enantioselective separation (AES) which is an extension of a concept of applying these factors to absolute asymmetric synthesis. The three factors may be applied simultaneously or, if their effects can be retained, consecutively. The resulting three mutually orthogonal or near orthogonal directors constitute a true chiral influence and their scalar triple product is the measure of the chirality of the system. AES can be executed in a chromatography-like microfluidic process in the presence of an electric field. It may be carried out on a chemically modified flat surface, a monolithic polymer column made of a mesoporous material, each having imparted directional properties. Separation parameters were estimated for these media and possible implications for the natural homochirality are discussed. PMID:16342798

  15. An absolute measure for a key currency

    NASA Astrophysics Data System (ADS)

    Oya, Shunsuke; Aihara, Kazuyuki; Hirata, Yoshito

    It is generally considered that the US dollar and the euro are the key currencies in the world and in Europe, respectively. However, there is no absolute general measure for a key currency. Here, we investigate the 24-hour periodicity of foreign exchange markets using a recurrence plot, and define an absolute measure for a key currency based on the strength of the periodicity. Moreover, we analyze the time evolution of this measure. The results show that the credibility of the US dollar has not decreased significantly since the Lehman shock, when the Lehman Brothers bankrupted and influenced the economic markets, and has increased even relatively better than that of the euro and that of the Japanese yen.

  16. From Hubble's NGSL to Absolute Fluxes

    NASA Technical Reports Server (NTRS)

    Heap, Sara R.; Lindler, Don

    2012-01-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R-l000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18-1.00 microns. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsll. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We are therefore developing an observing procedure that should yield fluxes with uncertainties less than 1 % and will take part in an HST proposal to observe up to 15 stars using this new procedure.

  17. Metallic Magnetic Calorimeters for Absolute Activity Measurement

    NASA Astrophysics Data System (ADS)

    Loidl, M.; Leblanc, E.; Rodrigues, M.; Bouchard, J.; Censier, B.; Branger, T.; Lacour, D.

    2008-05-01

    We present a prototype of metallic magnetic calorimeters that we are developing for absolute activity measurements of low energy emitting radionuclides. We give a detailed description of the realization of the prototype, containing an 55Fe source inside the detector absorber. We present the analysis of first data taken with this detector and compare the result of activity measurement with liquid scintillation counting. We also propose some ways for reducing the uncertainty on the activity determination with this new technique.

  18. Silicon Absolute X-Ray Detectors

    SciTech Connect

    Seely, John F.; Korde, Raj; Sprunck, Jacob; Medjoubi, Kadda; Hustache, Stephanie

    2010-06-23

    The responsivity of silicon photodiodes having no loss in the entrance window, measured using synchrotron radiation in the 1.75 to 60 keV range, was compared to the responsivity calculated using the silicon thickness measured using near-infrared light. The measured and calculated responsivities agree with an average difference of 1.3%. This enables their use as absolute x-ray detectors.

  19. Blood pressure targets and absolute cardiovascular risk.

    PubMed

    Odutayo, Ayodele; Rahimi, Kazem; Hsiao, Allan J; Emdin, Connor A

    2015-08-01

    In the Eighth Joint National Committee guideline on hypertension, the threshold for the initiation of blood pressure-lowering treatment for elderly adults (≥60 years) without chronic kidney disease or diabetes mellitus was raised from 140/90 mm Hg to 150/90 mm Hg. However, the committee was not unanimous in this decision, particularly because a large proportion of adults ≥60 years may be at high cardiovascular risk. On the basis of Eighth Joint National Committee guideline, we sought to determine the absolute 10-year risk of cardiovascular disease among these adults through analyzing the National Health and Nutrition Examination Survey (2005-2012). The primary outcome measure was the proportion of adults who were at ≥20% predicted absolute cardiovascular risk and above goals for the Seventh Joint National Committee guideline but reclassified as at target under the Eighth Joint National Committee guideline (reclassified). The Framingham General Cardiovascular Disease Risk Score was used. From 2005 to 2012, the surveys included 12 963 adults aged 30 to 74 years with blood pressure measurements, of which 914 were reclassified based on the guideline. Among individuals reclassified as not in need of additional treatment, the proportion of adults 60 to 74 years without chronic kidney disease or diabetes mellitus at ≥20% absolute risk was 44.8%. This corresponds to 0.8 million adults. The proportion at high cardiovascular risk remained sizable among adults who were not receiving blood pressure-lowering treatment. Taken together, a sizable proportion of reclassified adults 60 to 74 years without chronic kidney disease or diabetes mellitus was at ≥20% absolute cardiovascular risk. PMID:26056340

  20. Relative errors can cue absolute visuomotor mappings.

    PubMed

    van Dam, Loes C J; Ernst, Marc O

    2015-12-01

    When repeatedly switching between two visuomotor mappings, e.g. in a reaching or pointing task, adaptation tends to speed up over time. That is, when the error in the feedback corresponds to a mapping switch, fast adaptation occurs. Yet, what is learned, the relative error or the absolute mappings? When switching between mappings, errors with a size corresponding to the relative difference between the mappings will occur more often than other large errors. Thus, we could learn to correct more for errors with this familiar size (Error Learning). On the other hand, it has been shown that the human visuomotor system can store several absolute visuomotor mappings (Mapping Learning) and can use associated contextual cues to retrieve them. Thus, when contextual information is present, no error feedback is needed to switch between mappings. Using a rapid pointing task, we investigated how these two types of learning may each contribute when repeatedly switching between mappings in the absence of task-irrelevant contextual cues. After training, we examined how participants changed their behaviour when a single error probe indicated either the often-experienced error (Error Learning) or one of the previously experienced absolute mappings (Mapping Learning). Results were consistent with Mapping Learning despite the relative nature of the error information in the feedback. This shows that errors in the feedback can have a double role in visuomotor behaviour: they drive the general adaptation process by making corrections possible on subsequent movements, as well as serve as contextual cues that can signal a learned absolute mapping. PMID:26280315

  1. Absolute distance measurements by variable wavelength interferometry

    NASA Astrophysics Data System (ADS)

    Bien, F.; Camac, M.; Caulfield, H. J.; Ezekiel, S.

    1981-02-01

    This paper describes a laser interferometer which provides absolute distance measurements using tunable lasers. An active feedback loop system, in which the laser frequency is locked to the optical path length difference of the interferometer, is used to tune the laser wavelengths. If the two wavelengths are very close, electronic frequency counters can be used to measure the beat frequency between the two laser frequencies and thus to determine the optical path difference between the two legs of the interferometer.

  2. Absolute dosimetry for extreme-ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Berger, Kurt W.; Campiotti, Richard H.

    2000-06-01

    The accurate measurement of an exposure dose reaching the wafer on an extreme ultraviolet (EUV) lithographic system has been a technical challenge directly applicable to the evaluation of candidate EUV resist materials and calculating lithography system throughputs. We have developed a dose monitoring sensor system that can directly measure EUV intensities at the wafer plane of a prototype EUV lithographic system. This sensor system, located on the wafer stage adjacent to the electrostatic chuck used to grip wafers, operates by translating the sensor into the aerial image, typically illuminating an 'open' (unpatterned) area on the reticle. The absolute signal strength can be related to energy density at the wafer, and thus used to determine resist sensitivity, and the signal as a function of position can be used to determine illumination uniformity at the wafer plane. Spectral filtering to enhance the detection of 13.4 nm radiation was incorporated into the sensor. Other critical design parameters include the packaging and amplification technologies required to place this device into the space and vacuum constraints of a EUV lithography environment. We describe two approaches used to determine the absolute calibration of this sensor. The first conventional approach requires separate characterization of each element of the sensor. A second novel approach uses x-ray emission from a mildly radioactive iron source to calibrate the absolute response of the entire sensor system (detector and electronics) in a single measurement.

  3. Effectiveness, Productivity, and Excellence in American Schools.

    ERIC Educational Resources Information Center

    Chand, Krishan

    This paper argues that excellence in American education requires increased superintendent effectiveness and productivity. It provides examples of inadequate educational outcomes and lists recommendations for improvement. These recommendations include more effective superintendent selection procedures, better superintendent working conditions,…

  4. Teaching Comparative Statics with Microsoft Excel.

    ERIC Educational Resources Information Center

    Barreto, Humberto

    2001-01-01

    Describes a Web site that makes use of the Comparative Statics Wizard add-in feature for Microsoft Excel. Enables students to focus on economic problems involving optimality, rate of change, and equilibrium solutions. (JEH)

  5. 2011 Editors' Citations for Excellence in Refereeing

    NASA Astrophysics Data System (ADS)

    2012-12-01

    In the 2 October 2012 issue of Eos, the 2011 Editors' Citations for Excellence in Refereeing were announced (Eos, 93(40), 391-394, doi:10.1029/2012EO400012). The editors' citations recognize this special service to the Union, and these individuals are to be commended for consistently providing constructive and thoughtful reviews. The reviewers listed below were inadvertently omitted from that announcement. They, too, have been cited by editors of AGU journals for excellence in refereeing.

  6. Limitations of Using Microsoft Excel Version 2016 (MS Excel 2016) for Statistical Analysis for Medical Research.

    PubMed

    Tanavalee, Chotetawan; Luksanapruksa, Panya; Singhatanadgige, Weerasak

    2016-06-01

    Microsoft Excel (MS Excel) is a commonly used program for data collection and statistical analysis in biomedical research. However, this program has many limitations, including fewer functions that can be used for analysis and a limited number of total cells compared with dedicated statistical programs. MS Excel cannot complete analyses with blank cells, and cells must be selected manually for analysis. In addition, it requires multiple steps of data transformation and formulas to plot survival analysis graphs, among others. The Megastat add-on program, which will be supported by MS Excel 2016 soon, would eliminate some limitations of using statistic formulas within MS Excel. PMID:27135620

  7. Clock time is absolute and universal

    NASA Astrophysics Data System (ADS)

    Shen, Xinhang

    2015-09-01

    A critical error is found in the Special Theory of Relativity (STR): mixing up the concepts of the STR abstract time of a reference frame and the displayed time of a physical clock, which leads to use the properties of the abstract time to predict time dilation on physical clocks and all other physical processes. Actually, a clock can never directly measure the abstract time, but can only record the result of a physical process during a period of the abstract time such as the number of cycles of oscillation which is the multiplication of the abstract time and the frequency of oscillation. After Lorentz Transformation, the abstract time of a reference frame expands by a factor gamma, but the frequency of a clock decreases by the same factor gamma, and the resulting multiplication i.e. the displayed time of a moving clock remains unchanged. That is, the displayed time of any physical clock is an invariant of Lorentz Transformation. The Lorentz invariance of the displayed times of clocks can further prove within the framework of STR our earth based standard physical time is absolute, universal and independent of inertial reference frames as confirmed by both the physical fact of the universal synchronization of clocks on the GPS satellites and clocks on the earth, and the theoretical existence of the absolute and universal Galilean time in STR which has proved that time dilation and space contraction are pure illusions of STR. The existence of the absolute and universal time in STR has directly denied that the reference frame dependent abstract time of STR is the physical time, and therefore, STR is wrong and all its predictions can never happen in the physical world.

  8. Achieving Climate Change Absolute Accuracy in Orbit

    NASA Technical Reports Server (NTRS)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; Bowman, K.; Brindley, H.; Butler, J. J.; Collins, W.; Dykema, J. A.; Doelling, D. R.; Feldman, D. R.; Fox, N.; Huang, X.; Holz, R.; Huang, Y.; Jennings, D.; Jin, Z.; Johnson, D. G.; Jucks, K.; Kato, S.; Kratz, D. P.; Liu, X.; Lukashin, C.; Mannucci, A. J.; Phojanamongkolkij, N.; Roithmayr, C. M.; Sandford, S.; Taylor, P. C.; Xiong, X.

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  9. The National Geodetic Survey absolute gravity program

    NASA Astrophysics Data System (ADS)

    Peter, George; Moose, Robert E.; Wessells, Claude W.

    1989-03-01

    The National Geodetic Survey absolute gravity program will utilize the high precision afforded by the JILAG-4 instrument to support geodetic and geophysical research, which involves studies of vertical motions, identification and modeling of other temporal variations, and establishment of reference values. The scientific rationale of these objectives is given, the procedures used to collect gravity and environmental data in the field are defined, and the steps necessary to correct and remove unwanted environmental effects are stated. In addition, site selection criteria, methods of concomitant environmental data collection and relative gravity observations, and schedule and logistics are discussed.

  10. An absolute radius scale for Saturn's rings

    NASA Technical Reports Server (NTRS)

    Nicholson, Philip D.; Cooke, Maren L.; Pelton, Emily

    1990-01-01

    Radio and stellar occultation observations of Saturn's rings made by the Voyager spacecraft are discussed. The data reveal systematic discrepancies of almost 10 km in some parts of the rings, limiting some of the investigations. A revised solution for Saturn's rotation pole has been proposed which removes the discrepancies between the stellar and radio occultation profiles. Corrections to previously published radii vary from -2 to -10 km for the radio occultation, and +5 to -6 km for the stellar occultation. An examination of spiral density waves in the outer A Ring supports that the revised absolute radii are in error by no more than 2 km.

  11. Characterization of the DARA solar absolute radiometer

    NASA Astrophysics Data System (ADS)

    Finsterle, W.; Suter, M.; Fehlmann, A.; Kopp, G.

    2011-12-01

    The Davos Absolute Radiometer (DARA) prototype is an Electrical Substitution Radiometer (ESR) which has been developed as a successor of the PMO6 type on future space missions and ground based TSI measurements. The DARA implements an improved thermal design of the cavity detector and heat sink assembly to minimize air-vacuum differences and to maximize thermal symmetry of measuring and compensating cavity. The DARA also employs an inverted viewing geometry to reduce internal stray light. We will report on the characterization and calibration experiments which were carried out at PMOD/WRC and LASP (TRF).

  12. Absolute calibration of the Auger fluorescence detectors

    SciTech Connect

    Bauleo, P.; Brack, J.; Garrard, L.; Harton, J.; Knapik, R.; Meyhandan, R.; Rovero, A.C.; Tamashiro, A.; Warner, D.

    2005-07-01

    Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the combined effects of all detector components in a single measurement. The calibrated 2.5 m diameter light source fills the aperture, providing uniform illumination to each pixel. The known flux from the light source and the response of the acquisition system give the required calibration for each pixel. In the lab, light source uniformity is studied using CCD images and the intensity is measured relative to NIST-calibrated photodiodes. Overall uncertainties are presently 12%, and are dominated by systematics.

  13. Absolute angular positioning in ultrahigh vacuum

    SciTech Connect

    Schief, H.; Marsico, V.; Kern, K.

    1996-05-01

    Commercially available angular resolvers, which are routinely used in machine tools and robotics, are modified and adapted to be used under ultrahigh-vacuum (UHV) conditions. They provide straightforward and reliable measurements of angular positions for any kind of UHV sample manipulators. The corresponding absolute reproducibility is on the order of 0.005{degree}, whereas the relative resolution is better than 0.001{degree}, as demonstrated by high-resolution helium-reflectivity measurements. The mechanical setup and possible applications are discussed. {copyright} {ital 1996 American Institute of Physics.}

  14. Absolute method of measuring magnetic susceptibility

    USGS Publications Warehouse

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  15. Absolute Priority for a Vehicle in VANET

    NASA Astrophysics Data System (ADS)

    Shirani, Rostam; Hendessi, Faramarz; Montazeri, Mohammad Ali; Sheikh Zefreh, Mohammad

    In today's world, traffic jams waste hundreds of hours of our life. This causes many researchers try to resolve the problem with the idea of Intelligent Transportation System. For some applications like a travelling ambulance, it is important to reduce delay even for a second. In this paper, we propose a completely infrastructure-less approach for finding shortest path and controlling traffic light to provide absolute priority for an emergency vehicle. We use the idea of vehicular ad-hoc networking to reduce the imposed travelling time. Then, we simulate our proposed protocol and compare it with a centrally controlled traffic light system.

  16. Absolute absorption on the potassium D lines: theory and experiment

    NASA Astrophysics Data System (ADS)

    Hanley, Ryan K.; Gregory, Philip D.; Hughes, Ifan G.; Cornish, Simon L.

    2015-10-01

    We present a detailed study of the absolute Doppler-broadened absorption of a probe beam scanned across the potassium D lines in a thermal vapour. Spectra using a weak probe were measured on the 4S \\to 4P transition and compared to the theoretical model of the electric susceptibility detailed by Zentile et al (2015 Comput. Phys. Commun. 189 162-74) in the code named ElecSus. Comparisons were also made on the 4S \\to 5P transition with an adapted version of ElecSus. This is the first experimental test of ElecSus on an atom with a ground state hyperfine splitting smaller than that of the Doppler width. An excellent agreement was found between ElecSus and experimental measurements at a variety of temperatures with rms errors ˜ {10}-3. We have also demonstrated the use of ElecSus as an atomic vapour thermometry tool, and present a possible new measurement technique of transition decay rates which we predict to have a precision of ˜3 {kHz}.

  17. A high-precision mechanical absolute-rotation sensor.

    PubMed

    Venkateswara, Krishna; Hagedorn, Charles A; Turner, Matthew D; Arp, Trevor; Gundlach, Jens H

    2014-01-01

    We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad/√Hz above 30 mHz and 0.2 nrad/√Hz above 100 mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 μm above the pivot, giving an excellent horizontal displacement rejection of better than 3 × 10(-5) rad/m. The angle of the beam is read out optically using a high-sensitivity autocollimator. We have also built a tiltmeter with better than 1 nrad/√Hz sensitivity above 30 mHz. Co-located measurements using the two instruments allowed us to distinguish between background rotation signal at low frequencies and intrinsic instrument noise. The rotation sensor is useful for rotational seismology and for rejecting background rotation signal from seismometers in experiments demanding high levels of seismic isolation, such as Advanced Laser Interferometer Gravitational-wave Observatory. PMID:24517804

  18. Auto Draw from Excel Input Files

    NASA Technical Reports Server (NTRS)

    Strauss, Karl F.; Goullioud, Renaud; Cox, Brian; Grimes, James M.

    2011-01-01

    The design process often involves the use of Excel files during project development. To facilitate communications of the information in the Excel files, drawings are often generated. During the design process, the Excel files are updated often to reflect new input. The problem is that the drawings often lag the updates, often leading to confusion of the current state of the design. The use of this program allows visualization of complex data in a format that is more easily understandable than pages of numbers. Because the graphical output can be updated automatically, the manual labor of diagram drawing can be eliminated. The more frequent update of system diagrams can reduce confusion and reduce errors and is likely to uncover symmetric problems earlier in the design cycle, thus reducing rework and redesign.

  19. Determination of the absolute contours of optical flats

    NASA Technical Reports Server (NTRS)

    Primak, W.

    1969-01-01

    Emersons procedure is used to determine true absolute contours of optical flats. Absolute contours of standard flats are determined and a comparison is then made between standard and unknown flats. Contour differences are determined by deviation of Fizeau fringe.

  20. Standardization of the cumulative absolute velocity

    SciTech Connect

    O'Hara, T.F.; Jacobson, J.P. )

    1991-12-01

    EPRI NP-5930, A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set.

  1. Absolute rates of hole transfer in DNA.

    PubMed

    Senthilkumar, Kittusamy; Grozema, Ferdinand C; Guerra, Célia Fonseca; Bickelhaupt, F Matthias; Lewis, Frederick D; Berlin, Yuri A; Ratner, Mark A; Siebbeles, Laurens D A

    2005-10-26

    Absolute rates of hole transfer between guanine nucleobases separated by one or two A:T base pairs in stilbenedicarboxamide-linked DNA hairpins were obtained by improved kinetic analysis of experimental data. The charge-transfer rates in four different DNA sequences were calculated using a density-functional-based tight-binding model and a semiclassical superexchange model. Site energies and charge-transfer integrals were calculated directly as the diagonal and off-diagonal matrix elements of the Kohn-Sham Hamiltonian, respectively, for all possible combinations of nucleobases. Taking into account the Coulomb interaction between the negative charge on the stilbenedicarboxamide linker and the hole on the DNA strand as well as effects of base pair twisting, the relative order of the experimental rates for hole transfer in different hairpins could be reproduced by tight-binding calculations. To reproduce quantitatively the absolute values of the measured rate constants, the effect of the reorganization energy was taken into account within the semiclassical superexchange model for charge transfer. The experimental rates could be reproduced with reorganization energies near 1 eV. The quantum chemical data obtained were used to discuss charge carrier mobility and hole-transport equilibria in DNA. PMID:16231945

  2. Transient absolute robustness in stochastic biochemical networks.

    PubMed

    Enciso, German A

    2016-08-01

    Absolute robustness allows biochemical networks to sustain a consistent steady-state output in the face of protein concentration variability from cell to cell. This property is structural and can be determined from the topology of the network alone regardless of rate parameters. An important question regarding these systems is the effect of discrete biochemical noise in the dynamical behaviour. In this paper, a variable freezing technique is developed to show that under mild hypotheses the corresponding stochastic system has a transiently robust behaviour. Specifically, after finite time the distribution of the output approximates a Poisson distribution, centred around the deterministic mean. The approximation becomes increasingly accurate, and it holds for increasingly long finite times, as the total protein concentrations grow to infinity. In particular, the stochastic system retains a transient, absolutely robust behaviour corresponding to the deterministic case. This result contrasts with the long-term dynamics of the stochastic system, which eventually must undergo an extinction event that eliminates robustness and is completely different from the deterministic dynamics. The transiently robust behaviour may be sufficient to carry out many forms of robust signal transduction and cellular decision-making in cellular organisms. PMID:27581485

  3. Absolute Electron Extraction Efficiency of Liquid Xenon

    NASA Astrophysics Data System (ADS)

    Kamdin, Katayun; Mizrachi, Eli; Morad, James; Sorensen, Peter

    2016-03-01

    Dual phase liquid/gas xenon time projection chambers (TPCs) currently set the world's most sensitive limits on weakly interacting massive particles (WIMPs), a favored dark matter candidate. These detectors rely on extracting electrons from liquid xenon into gaseous xenon, where they produce proportional scintillation. The proportional scintillation from the extracted electrons serves to internally amplify the WIMP signal; even a single extracted electron is detectable. Credible dark matter searches can proceed with electron extraction efficiency (EEE) lower than 100%. However, electrons systematically left at the liquid/gas boundary are a concern. Possible effects include spontaneous single or multi-electron proportional scintillation signals in the gas, or charging of the liquid/gas interface or detector materials. Understanding EEE is consequently a serious concern for this class of rare event search detectors. Previous EEE measurements have mostly been relative, not absolute, assuming efficiency plateaus at 100%. I will present an absolute EEE measurement with a small liquid/gas xenon TPC test bed located at Lawrence Berkeley National Laboratory.

  4. Sentinel-2/MSI absolute calibration: first results

    NASA Astrophysics Data System (ADS)

    Lonjou, V.; Lachérade, S.; Fougnie, B.; Gamet, P.; Marcq, S.; Raynaud, J.-L.; Tremas, T.

    2015-10-01

    Sentinel-2 is an optical imaging mission devoted to the operational monitoring of land and coastal areas. It is developed in partnership between the European Commission and the European Space Agency. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. It will offer a unique combination of global coverage with a wide field of view (290km), a high revisit (5 days with two satellites), a high resolution (10m, 20m and 60m) and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains). CNES is involved in the instrument commissioning in collaboration with ESA. This paper reviews all the techniques that will be used to insure an absolute calibration of the 13 spectral bands better than 5% (target 3%), and will present the first results if available. First, the nominal calibration technique, based on an on-board sun diffuser, is detailed. Then, we show how vicarious calibration methods based on acquisitions over natural targets (oceans, deserts, and Antarctica during winter) will be used to check and improve the accuracy of the absolute calibration coefficients. Finally, the verification scheme, exploiting photometer in-situ measurements over Lacrau plain, is described. A synthesis, including spectral coherence, inter-methods agreement and temporal evolution, will conclude the paper.

  5. Absolute Spectrophotometry of 237 Open Cluster Stars

    NASA Astrophysics Data System (ADS)

    Clampitt, L.; Burstein, D.

    1994-12-01

    We present absolute spectrophotometry of 237 stars in 7 nearby open clusters: Hyades, Pleiades, Alpha Persei, Praesepe, Coma Berenices, IC 4665, and M 39. The observations were taken using the Wampler single-channel scanner (Wampler 1966) on the Crossley 0.9m telescope at Lick Observatory from July 1973 through December 1974. 21 bandpasses spanning the spectral range 3500 Angstroms to 7780 Angstroms were observed for each star, with bandwiths ranging from 32Angstroms to 64 Angstroms. Data are standardized to the Hayes--Latham (1975) system. Our measurements are compared to filter colors on the Johnson BV, Stromgren ubvy, and Geneva U V B_1 B_2 V_1 G systems, as well as to spectrophotometry of a few stars published by Gunn, Stryker & Tinsley and in the Spectrophotometric Standards Catalog (Adelman; as distributed by the NSSDC). Both internal and external comparisons to the filter systems indicate a formal statistical accuracy per bandpass of 0.01 to 0.02 mag, with apparent larger ( ~ 0.03 mag) differences in absolute calibration between this data set and existing spectrophotometry. These data will comprise part of the spectrophotometry that will be used to calibrate the Beijing-Arizona-Taipei-Connecticut Color Survey of the Sky (see separate paper by Burstein et al. at this meeting).

  6. A Conceptual Approach to Absolute Value Equations and Inequalities

    ERIC Educational Resources Information Center

    Ellis, Mark W.; Bryson, Janet L.

    2011-01-01

    The absolute value learning objective in high school mathematics requires students to solve far more complex absolute value equations and inequalities. When absolute value problems become more complex, students often do not have sufficient conceptual understanding to make any sense of what is happening mathematically. The authors suggest that the…

  7. Using, Seeing, Feeling, and Doing Absolute Value for Deeper Understanding

    ERIC Educational Resources Information Center

    Ponce, Gregorio A.

    2008-01-01

    Using sticky notes and number lines, a hands-on activity is shared that anchors initial student thinking about absolute value. The initial point of reference should help students successfully evaluate numeric problems involving absolute value. They should also be able to solve absolute value equations and inequalities that are typically found in…

  8. 20 CFR 404.1205 - Absolute coverage groups.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Absolute coverage groups. 404.1205 Section... INSURANCE (1950- ) Coverage of Employees of State and Local Governments What Groups of Employees May Be Covered § 404.1205 Absolute coverage groups. (a) General. An absolute coverage group is a...

  9. Curriculum for Excellence Science: Vision or Confusion?

    ERIC Educational Resources Information Center

    Day, Stephen; Bryce, Tom

    2013-01-01

    Policy studies in science education do not have a particularly high profile. For science teachers, policy lurks in the background, somewhat disconnected from their normal classroom practice; for many, it is simply taken-for-granted. This paper analyses policy documents which have emerged from Curriculum for Excellence ("CfE") that impact…

  10. Measurement of Excellence in Newspaper Writing Courses.

    ERIC Educational Resources Information Center

    Stone, Gerald

    1990-01-01

    Charts the dimensions of introductory newspaper news writing classes as they are taught today in colleges and universities. Defines a model for excellence in the class by distinguishing between courses in nationally recognized writing programs versus those in programs that have not attained such acclaim. (MM)

  11. Budgeting for the Kentucky Educational Excellence Scholarship

    ERIC Educational Resources Information Center

    Letteer, Melvin E.

    2008-01-01

    The Kentucky Educational Excellence Scholarship (KEES) is a broad-based initiative that provides the opportunity for traditional and nontraditional secondary school students and General Educational Development (GED) recipients to earn scholarships that may be used at Kentucky colleges, universities, and selected technical and vocational education…

  12. 75 FR 48661 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-11

    ...The U.S. Secretary of Education (Secretary) announces the establishment of the Equity and Excellence Commission (Equity Commission or Commission). The Federal Advisory Committee Act (FACA) (Pub. L. 92-463, as amended; 5 U.S.C.A., Appendix 2) shall govern the Equity Commission. Purpose: The Secretary is establishing the Commission in order to collect information, analyze issues, and obtain......

  13. 77 FR 31605 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-29

    ...This notice sets forth the schedule and proposed agenda of an up- coming meeting of the Equity and Excellence Commission (Commission). The notice also describes the functions of the Commission. Notice of this meeting is required by section 10(a)(2) of the Federal Advisory Committee Act (FACA) and is intended to notify the public of their opportunity to...

  14. Towards a Performance Support Centre of Excellence.

    ERIC Educational Resources Information Center

    Bezanson, William R.

    1995-01-01

    Discussion of performance support focuses on Canada's Bell-Northern Research's views of embedded performance support systems. The establishment of a corporate center of excellence for performance support system (PSS) development is explained; a pilot project is described; and a business case showing the benefits of implementing a PSS is presented.…

  15. It's Time to Recognize Excellent Teachers.

    ERIC Educational Resources Information Center

    Berger, Stuart D.

    1986-01-01

    The Teacher Plus Program (TPP) currently used in the Frederick County (Maryland) Public Schools shares some characteristics with a system for rewarding excellence in teachers that was originally proposed by Myron Lieberman and has since been championed by Albert Shanker. Lieberman's proposal called for the creation of national educational…

  16. Curriculum for Excellence and Interdisciplinary Learning

    ERIC Educational Resources Information Center

    Humes, Walter

    2013-01-01

    This paper examines the recommendations contained in Curriculum for Excellence (CfE) aimed at encouraging the integration of knowledge, skills and understanding across different areas of the curriculum. It first outlines what is said in the official CfE documentation and supporting materials produced by Education Scotland, noting the absence of…

  17. 77 FR 29621 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-18

    ..., in Room 1W105/108. FOR FURTHER INFORMATION CONTACT: Guy Johnson, Designated Federal Official, Equity... equitycommission@ed.gov or via U.S. mail to Guy Johnson, Designated Federal Official, Equity and Excellence... contact Guy Johnson at (202) 453-6567 or by email at equitycommission@ed.gov . Individuals who will...

  18. Introduction to 3D Graphics through Excel

    ERIC Educational Resources Information Center

    Benacka, Jan

    2013-01-01

    The article presents a method of explaining the principles of 3D graphics through making a revolvable and sizable orthographic parallel projection of cuboid in Excel. No programming is used. The method was tried in fourteen 90 minute lessons with 181 participants, which were Informatics teachers, undergraduates of Applied Informatics and gymnasium…

  19. 77 FR 18798 - Equity and Excellence Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-28

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF EDUCATION Equity and Excellence Commission AGENCY: U.S. Department of Education. ACTION: Notice; Advisory Committee Meeting Cancellation. SUMMARY: The Department of Education gives notice of the cancellation of the...

  20. Excel Yourself with Personalised Email Messages

    ERIC Educational Resources Information Center

    McClean, Stephen

    2008-01-01

    Combining the Excel spreadsheet with an email program provides a very powerful tool for sending students personalised emails. Most email clients now support a Mail Merge facility whereby a generic template is created and information unique to each student record in the spreadsheet is filled into that template, generating tens if not hundreds of…

  1. Catholic Intellectual Excellence: Challenges and Visions.

    ERIC Educational Resources Information Center

    Current Issues in Catholic Higher Education, 1991

    1991-01-01

    This publication on the subject of Catholic intellectual excellence at the university level reproduces six papers from an annual meeting and four papers on John Henry Cardinal Newman in celebration of the 100th anniversary of his death in 1890. The papers on Newman include the following: "Newman's Idea of a University: Is It Viable Today?" (E. J.…

  2. Implementing Service Excellence in Higher Education

    ERIC Educational Resources Information Center

    Khan, Hina; Matlay, Harry

    2009-01-01

    Purpose: The purpose of this paper is to provide a critical analysis of the importance of service excellence in higher education. Design/methodology/approach: The research upon which this paper is based employed a phenomenological approach. This method was selected for its focus on respondent perceptions and experiences. Both structured and…

  3. Teaching excellence: what great teachers teach us.

    PubMed

    Johnson-Farmer, Barbara; Frenn, Marilyn

    2009-01-01

    Given the shortage of nurse educators, we sought to better understand teaching excellence because it is crucial for developing the next generation of nurses. A grounded theory approach was used. The sample included 17 respondents, thought to be excellent teachers, from universities across the United States. Consenting respondents were asked, "What do you do to bring nursing to life with your students?" Using line-by-line coding and the constant comparative method, five major themes emerged: (a) engagement, (b) relevance, (c) student centeredness, (d) facilitation of learning, and (e) dynamic process of becoming an excellent nursing educator. We found that the core category, engagement, included the faculty being (a) current and knowledgeable, (b) being clear in communication of objectives/outcomes, (c) being student centered, (d) being able to draw all students into active questioning and learning so that the process of discovery is enjoyable, and (e) using multiple strategies in teaching the content. The process of becoming an excellent teacher involved "change from 'instiller' to 'facilitator' and laid the foundation for continued development of my teaching self." Those beginning to teach or seeking to improve their teaching may find the results enlightening. PMID:19751930

  4. Families as Partners in Centers for Excellence.

    ERIC Educational Resources Information Center

    Hamilton, Muriel E.; Roach, Mary A.; Riley, David A.

    2003-01-01

    Strengthening family involvement in early childhood programs became a fundamental component of the Wisconsin Early Childhood Excellence Initiative. The initiative's strategies for encouraging family involvement include: creating a welcoming atmosphere; actively involving parents, children, and other family members in the education process;…

  5. Textbooks for Responsible Data Analysis in Excel

    ERIC Educational Resources Information Center

    Garrett, Nathan

    2015-01-01

    With 27 million users, Excel (Microsoft Corporation, Seattle, WA) is the most common business data analysis software. However, audits show that almost all complex spreadsheets have errors. The author examined textbooks to understand why responsible data analysis is taught. A purposeful sample of 10 textbooks was coded, and then compared against…

  6. 2000 Awards of Excellence in Architectural Design.

    ERIC Educational Resources Information Center

    School Business Affairs, 2001

    2001-01-01

    In 2000, ASBO International Certificates of Excellence went to Arcon Associates, Inc., in Lombard, Illinois; Barbour/LaDouceur Architects and Ellerbe Becket in Minneapolis, Minnesota; Fanning/Howey Associates in Indianapolis, Indiana; and Tomaino Iamello Associates in Deal, New Jersey, for school building construction/renovation projects. (MLH)

  7. Tips for Using Microsoft Excel in Assessment.

    ERIC Educational Resources Information Center

    Kahan, David

    Acknowledging the need for additional practical resources for integrating technology into physical education assessment, this paper provides strategies and step-by-step instructions for incorporating Microsoft Excel into physical educators' assessment tools. The first section briefly reviews the literature on assessment in physical education. The…

  8. Teaching Excellence for All Our Students

    ERIC Educational Resources Information Center

    King, Sabrina Hope; Watson, Audra

    2010-01-01

    Education has the power to change the world. We wrote this article in the spirit of the hope embodied by the election of President Obama and the critical need for improved teaching to benefit all the nation's students. This article offers a synthesis of the characteristics of excellent teaching for the diverse student population. This article…

  9. AWARE (Alabama Working at Reading Excellence).

    ERIC Educational Resources Information Center

    Alabama Univ., Tuscaloosa. Coll. of Education.

    The selected material from the Right-to-Read Institute consists of: (1) Goals of the Institute and Specific Objectives, (2) Alabama Working at Reading Excellence Program, (3) What is the Right to Read?, (4) Objectives, (5) Activities - Studies, (6) Inventory, (7) Recommendations, (8) Alabama Population Characteristics and (9) Sounds and Light for…

  10. Award for Excellence in Facilities Management.

    ERIC Educational Resources Information Center

    Gretchen, Stephanie

    1989-01-01

    Recipients of Association of Physical Plant Administrators awards for excellence in facilities management in various institutional categories are noted. Specific areas of outstanding achievement include cooperation, energy conservation, attention to detail, use of customer feedback, emergency preparedness, individual employee recognition, utility…

  11. Equilibrator: Modeling Chemical Equilibria with Excel

    ERIC Educational Resources Information Center

    Vander Griend, Douglas A.

    2011-01-01

    Equilibrator is a Microsoft Excel program for learning about chemical equilibria through modeling, similar in function to EQS4WIN, which is no longer supported and does not work well with newer Windows operating systems. Similar to EQS4WIN, Equilibrator allows the user to define a system with temperature, initial moles, and then either total…

  12. Using Professional Software To Enhance Teaching Excellence.

    ERIC Educational Resources Information Center

    Coulter, Fredrik V.; Stryker, Judson P.

    Commitment to teaching excellence is enhanced when innovative and creative methods are introduced into the education setting. With today's rapidly changing technology, professional and presentation software can be used to improve the learning process. At Florida's Stetson University, professional estate, gift, and fiduciary software packages were…

  13. High Five: Building Capacity for School Excellence

    ERIC Educational Resources Information Center

    McCullen, Caroline

    2006-01-01

    In 2004, five North Carolina school districts combined forces with five corporate foundations to leverage their collective wisdom and develop regional strategies for school improvement. The result was the High Five Regional Partnership for High School Excellence, a corporate-public sector effort that had the common goal of improving graduation…

  14. Safety and Excellence. Safety in the Schools

    ERIC Educational Resources Information Center

    Merrow, John

    2004-01-01

    As far as schools are concerned, there are three kinds of safety: physical, emotional, and intellectual. Excellence demands all three, while "good enough" schools are simply physically safe. How can parents and others determine whether a school is physically safe? It's always good to find out how many students were suspended at a particular…

  15. District Awards for Teacher Excellence: Research Brief

    ERIC Educational Resources Information Center

    National Center on Performance Incentives, 2010

    2010-01-01

    Since 2008 Texas's District Awards for Teacher Excellence (D.A.T.E.) program has provided grants to districts for the implementation of locally designed incentive pay plans. The 2010-11 school year is the third year of the D.A.T.E. incentive pay plans with approximately $197 million in annual state funding. This research brief summarizes the key…

  16. 2010 editors' citations for excellence in refereeing

    NASA Astrophysics Data System (ADS)

    2011-09-01

    The reviewers listed on these pages have been cited by editors of AGU journals for excellence in refereeing. The editors' citations recognize this special service to the Union. These individuals (photographs provided as available) are to be commended for consistently providing constructive and thoughtful reviews.

  17. 2009 Editors' Citations for Excellence in Refereeing

    NASA Astrophysics Data System (ADS)

    2010-09-01

    The reviewers listed on these pages have been cited by editors of AGU journals for excellence in refereeing. The editors’ citations recognize this special service to the Union. These individuals (photographs provided as available) are commended for consistently providing constructive and thoughtful reviews.

  18. 2011 editors' citations for excellence in refereeing

    NASA Astrophysics Data System (ADS)

    Anonymous

    2012-10-01

    The reviewers listed below have been cited by editors of AGU journals for excellence in refereeing. The editors' citations recognize this special service to the Union, and these individuals (photographs provided as available) are to be commended for consistently providing constructive and thoughtful reviews.

  19. Standards of Excellence in Budget Presentation.

    ERIC Educational Resources Information Center

    Strachota, Dennis

    The Association of School Business Officials International (ASBO) inaugurated the Meritorious Budget Awards Program (MBA) in July 1995. ASBO specifically created this program to help school business administrators achieve a standard of excellence in budget presentation. This book is intended to serve as a practical guide to the MBA program and…

  20. Excellence Center for High Technology Transfer.

    ERIC Educational Resources Information Center

    Ismail, M. I.; Al-Turkait, A. A.

    Centers for technology transfer are available almost everywhere based on the availability of interested experts and funding. The objective of this monograph is to introduce the assured system that results in excellence in services and expectations from technology transfer. The focus is on simple techniques of potential interest for community and…

  1. Designing Quality Service: The Service Excellence Model.

    ERIC Educational Resources Information Center

    Ellicott, Michael A.; Conard, Rodney J.

    1997-01-01

    Recent experiences of manufacturing and commercial service industries provide insights to college facilities managers for combining downsizing with quality improvement. The Service Excellence Model emphasizes creation of shared responsibility, focus on core service processes, empowerment of cross-functional process-improvement teams, performance…

  2. Reading Excellence Act (REA): A Progress Report.

    ERIC Educational Resources Information Center

    Shannon, David M.

    Three analyses were conducted for this progress report of the Reading Excellence Act as implemented in Alabama public schools. The first analysis involved third grade reading comprehension scores over the 3-year period (1999-2001). Overall, reading comprehension scores remained stable. Based on multiple criteria, schools that either failed to meet…

  3. The Excellence of Play. Second Edition

    ERIC Educational Resources Information Center

    Moyles, Janet, Ed.

    2005-01-01

    This second edition of "The Excellence of Play" encapsulates all of the many changes that have taken place in early childhood in the last decade. It examines the vital importance of play as a tool for learning and teaching for children and practitioners, supporting all those who work in early childhood education and care in developing and…

  4. The solar absolute spectral irradiance 1150-3173 A - May 17, 1982

    NASA Technical Reports Server (NTRS)

    Mount, G. H.; Rottman, G. J.

    1983-01-01

    The full-disk solar spectral irradiance in the spectral range 1150-3173 A was obtained from a rocket observation above White Sands Missile Range, NM, on May 17, 1982, half way in time between solar maximum and solar minimum. Comparison with measurements made during solar maximum in 1980 indicate a large decrease in the absolute solar irradiance at wavelengths below 1900 A to approximately solar minimum values. No change above 1900 A from solar maximum to this flight was observed to within the errors of the measurements. Irradiance values lower than the Broadfoot results in the 2100-2500 A spectral range are found, but excellent agreement with Broadfoot between 2500 and 3173 A is found. The absolute calibration of the instruments for this flight was accomplished at the National Bureau of Standards Synchrotron Radiation Facility which significantly improves calibration of solar measurements made in this spectral region.

  5. Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

    SciTech Connect

    Mackinnon, A; Casey, D; Frenje, J A; Johnson, M G; Seguin, F H; Li, C K; Petrasso, R D; Glebov, V Y; Katz, J; Knauer, J; Meyerhofer, D; Sangster, T; Bionta, R; Bleuel, D; Hachett, S P; Hartouni, E; Lepape, S; Mckernan, M; Moran, M; Yeamans, C

    2012-05-03

    A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  6. Use of Absolute and Comparative Performance Feedback in Absolute and Comparative Judgments and Decisions

    ERIC Educational Resources Information Center

    Moore, Don A.; Klein, William M. P.

    2008-01-01

    Which matters more--beliefs about absolute ability or ability relative to others? This study set out to compare the effects of such beliefs on satisfaction with performance, self-evaluations, and bets on future performance. In Experiment 1, undergraduate participants were told they had answered 20% correct, 80% correct, or were not given their…

  7. Use of a Sampling Area-Adjusted Adenosine Triphosphate Bioluminescence Assay Based on Digital Image Quantification to Assess the Cleanliness of Hospital Surfaces.

    PubMed

    Ho, Yu-Huai; Wang, Lih-Shinn; Jiang, Hui-Li; Chang, Chih-Hui; Hsieh, Chia-Jung; Chang, Dan-Chi; Tu, Hsin-Yu; Chiu, Tan-Yun; Chao, Huei-Jen; Tseng, Chun-Chieh

    2016-01-01

    Contaminated surfaces play an important role in the transmission of pathogens. We sought to establish a criterion that could indicate "cleanliness" using a sampling area-adjusted adenosine triphosphate (ATP) assay. In the first phase of the study, target surfaces were selected for swab sampling before and after daily cleaning; then, an aerobic colony count (ACC) plate assay of bacteria and antibiotic-resistant bacteria was conducted. ATP swabs were also tested, and the ATP readings were reported as relative light units (RLUs). The results of the ACC and ATP assays were adjusted according to the sampling area. During the second phase of the study, a new cleaning process employing sodium dichloroisocyanurate (NaDCC) was implemented for comparison. Using the criterion of 2.5 colony-forming units (CFU)/cm², 45% of the sampled sites were successfully cleaned during phase one of the study. During phase two, the pass rates of the surface samples (64%) were significantly improved, except under stringent (5 RLU/cm²) and lax (500 RLU) ATP criteria. Using receiver-operating characteristic curve analysis, the best cut-off point for an area-adjusted ATP level was 7.34 RLU/cm², which corresponded to culture-assay levels of <2.5 CFU/cm². An area adjustment of the ATP assay improved the degree of correlation with the ACC-assay results from weak to moderate. PMID:27294944

  8. Absolute calibration of ultraviolet filter photometry

    NASA Technical Reports Server (NTRS)

    Bless, R. C.; Fairchild, T.; Code, A. D.

    1972-01-01

    The essential features of the calibration procedure can be divided into three parts. First, the shape of the bandpass of each photometer was determined by measuring the transmissions of the individual optical components and also by measuring the response of the photometer as a whole. Secondly, each photometer was placed in the essentially-collimated synchrotron radiation bundle maintained at a constant intensity level, and the output signal was determined from about 100 points on the objective. Finally, two or three points on the objective were illuminated by synchrotron radiation at several different intensity levels covering the dynamic range of the photometers. The output signals were placed on an absolute basis by the electron counting technique described earlier.

  9. MAGSAT: Vector magnetometer absolute sensor alignment determination

    NASA Technical Reports Server (NTRS)

    Acuna, M. H.

    1981-01-01

    A procedure is described for accurately determining the absolute alignment of the magnetic axes of a triaxial magnetometer sensor with respect to an external, fixed, reference coordinate system. The method does not require that the magnetic field vector orientation, as generated by a triaxial calibration coil system, be known to better than a few degrees from its true position, and minimizes the number of positions through which a sensor assembly must be rotated to obtain a solution. Computer simulations show that accuracies of better than 0.4 seconds of arc can be achieved under typical test conditions associated with existing magnetic test facilities. The basic approach is similar in nature to that presented by McPherron and Snare (1978) except that only three sensor positions are required and the system of equations to be solved is considerably simplified. Applications of the method to the case of the MAGSAT Vector Magnetometer are presented and the problems encountered discussed.

  10. Absolute geostrophic currents in global tropical oceans

    NASA Astrophysics Data System (ADS)

    Yang, Lina; Yuan, Dongliang

    2016-03-01

    A set of absolute geostrophic current (AGC) data for the period January 2004 to December 2012 are calculated using the P-vector method based on monthly gridded Argo profiles in the world tropical oceans. The AGCs agree well with altimeter geostrophic currents, Ocean Surface Current Analysis-Real time currents, and moored current-meter measurements at 10-m depth, based on which the classical Sverdrup circulation theory is evaluated. Calculations have shown that errors of wind stress calculation, AGC transport, and depth ranges of vertical integration cannot explain non-Sverdrup transport, which is mainly in the subtropical western ocean basins and equatorial currents near the Equator in each ocean basin (except the North Indian Ocean, where the circulation is dominated by monsoons). The identified non-Sverdrup transport is thereby robust and attributed to the joint effect of baroclinicity and relief of the bottom (JEBAR) and mesoscale eddy nonlinearity.

  11. Absolute Measurement of Electron Cloud Density

    SciTech Connect

    Covo, M K; Molvik, A W; Cohen, R H; Friedman, A; Seidl, P A; Logan, G; Bieniosek, F; Baca, D; Vay, J; Orlando, E; Vujic, J L

    2007-06-21

    Beam interaction with background gas and walls produces ubiquitous clouds of stray electrons that frequently limit the performance of particle accelerator and storage rings. Counterintuitively we obtained the electron cloud accumulation by measuring the expelled ions that are originated from the beam-background gas interaction, rather than by measuring electrons that reach the walls. The kinetic ion energy measured with a retarding field analyzer (RFA) maps the depressed beam space-charge potential and provides the dynamic electron cloud density. Clearing electrode current measurements give the static electron cloud background that complements and corroborates with the RFA measurements, providing an absolute measurement of electron cloud density during a 5 {micro}s duration beam pulse in a drift region of the magnetic transport section of the High-Current Experiment (HCX) at LBNL.

  12. Absolute instability of a viscous hollow jet

    NASA Astrophysics Data System (ADS)

    Gañán-Calvo, Alfonso M.

    2007-02-01

    An investigation of the spatiotemporal stability of hollow jets in unbounded coflowing liquids, using a general dispersion relation previously derived, shows them to be absolutely unstable for all physical values of the Reynolds and Weber numbers. The roots of the symmetry breakdown with respect to the liquid jet case, and the validity of asymptotic models are here studied in detail. Asymptotic analyses for low and high Reynolds numbers are provided, showing that old and well-established limiting dispersion relations [J. W. S. Rayleigh, The Theory of Sound (Dover, New York, 1945); S. Chandrasekhar, Hydrodynamic and Hydromagnetic Stability (Dover, New York, 1961)] should be used with caution. In the creeping flow limit, the analysis shows that, if the hollow jet is filled with any finite density and viscosity fluid, a steady jet could be made arbitrarily small (compatible with the continuum hypothesis) if the coflowing liquid moves faster than a critical velocity.

  13. Stitching interferometry: recent results and absolute calibration

    NASA Astrophysics Data System (ADS)

    Bray, Michael

    2004-02-01

    Stitching Interferometry is a method of analysing large optical components using a standard "small" interferometer. This result is obtained by taking multiple overlapping images of the large component, and numerically "stitching" these sub-apertures together. We have already reported the industrial use our Stitching Interferometry systems (Previous SPIE symposia), but experimental results had been lacking because this technique is still new, and users needed to get accustomed to it before producing reliable measurements. We now have more results. We will report user comments and show new, unpublished results. We will discuss sources of error, and show how some of these can be reduced to arbitrarily small values. These will be discussed in some detail. We conclude with a few graphical examples of absolute measurements performed by us.

  14. Swarm's Absolute Scalar Magnetometer metrological performances

    NASA Astrophysics Data System (ADS)

    Leger, J.; Fratter, I.; Bertrand, F.; Jager, T.; Morales, S.

    2012-12-01

    The Absolute Scalar Magnetometer (ASM) has been developed for the ESA Earth Observation Swarm mission, planned for launch in November 2012. As its Overhauser magnetometers forerunners flown on Oersted and Champ satellites, it will deliver high resolution scalar measurements for the in-flight calibration of the Vector Field Magnetometer manufactured by the Danish Technical University. Latest results of the ground tests carried out to fully characterize all parameters that may affect its accuracy, both at instrument and satellite level, will be presented. In addition to its baseline function, the ASM can be operated either at a much higher sampling rate (burst mode at 250 Hz) or in a dual mode where it also delivers vector field measurements as a by-product. The calibration procedure and the relevant vector performances will be discussed.

  15. Absolute nonlocality via distributed computing without communication

    NASA Astrophysics Data System (ADS)

    Czekaj, Ł.; Pawłowski, M.; Vértesi, T.; Grudka, A.; Horodecki, M.; Horodecki, R.

    2015-09-01

    Understanding the role that quantum entanglement plays as a resource in various information processing tasks is one of the crucial goals of quantum information theory. Here we propose an alternative perspective for studying quantum entanglement: distributed computation of functions without communication between nodes. To formalize this approach, we propose identity games. Surprisingly, despite no signaling, we obtain that nonlocal quantum strategies beat classical ones in terms of winning probability for identity games originating from certain bipartite and multipartite functions. Moreover we show that, for a majority of functions, access to general nonsignaling resources boosts success probability two times in comparison to classical ones for a number of large enough outputs. Because there are no constraints on the inputs and no processing of the outputs in the identity games, they detect very strong types of correlations: absolute nonlocality.

  16. Samuel P. Massie Chair of Excellence Program

    SciTech Connect

    Johnson, James H

    2014-12-15

    Abstract In 1994 the Department of Energy established the DOE Chair of Excellence Professorship in Environmental Disciplines Program. In 2004, the Massie Chair of Excellence Professor at Howard University transitioned from Dr. Edward Martin to Dr. James H. Johnson, Jr. At the time of his appointment Dr. Johnson served as professor of civil engineering and Dean of the College of Engineering, Architecture and Computer Sciences. Program activities under Dr. Johnson were in the following areas: • Increase the institution’s capacity to conduct scientific research and technical investigations at the cutting-edge. • Promote interactions, collaborations and partnerships between the private sector, Federal agencies, majority research institutes and other HBCUs. • Assist other HBCUs in reaching parity in engineering and related fields. • Mentor young investigators and be a role model for students.

  17. Understanding Statistical Mechanics and Biophysics Using Excel

    NASA Astrophysics Data System (ADS)

    Nelson, Peter

    2009-03-01

    A new approach to teaching statistical mechanics and biophysics is presented using the classic two-box system from statistical mechanics as an example. This approach makes advanced physics concepts accessible to a broad audience including undergraduates with no calculus background. Students develop a simple Excel spreadsheet that implements a kinetic Monte Carlo (kMC) simulation algorithm ``from scratch''. The students discover for themselves the properties of the system by analyzing the simulation output in a directed, activity-based exercise. By changing the number and initial distribution of the particles, students see how the system approaches equilibrium and how system variability changes with system size. A finite difference solution is also implemented in Excel, and students compare its predictions with the kMC results. This approach is quite different from using ``canned'' computer demonstrations, as students design, implement and debug the simulation themselves -- ensuring that they understand the model system intimately.

  18. Center of excellence in laser medicine

    SciTech Connect

    Parrish, J.A.

    1992-01-01

    Achievements during the first six months of funding to prepare for a Center of Excellence in biomedical laser development include limited specific research projects within the Center's three broad interest areas, and program development to establish the Center and its activities. Progress in the three interest areas -- new medical laser systems development, optical diagnostics, and photosensitization, is reported. Feasibility studies and prototype development were emphasized, to enhance establishing a substantial Center through future support. Specific projects are an optimized laser-catheter system for reversal of vasospasm; optical detection of major skin burn depth and cancers using fluorescent drugs, and photosensitization of vascular tissues. In addition, an interdepartmental Laser Center was established at MGH to enhance collaborations and institutional committment to the Center of Excellence. Competitive postdoctoral research fellowships, with provision for matching funds from other departments, have been announced.

  19. Maintaining technical excellence requires a national plan

    NASA Technical Reports Server (NTRS)

    Davidson, T. F.

    1991-01-01

    To meet the challenge of technical excellence, AIA established a rocket propulsion committee to develop the National Rocket Propulsion Strategic Plan. Developing such a plan required a broad spectrum of experience and disciplines. The Strategic Plan team needed the participation of industry, government, and academia. The plan provides, if followed, a means for the U.S. to maintain technical excellence and world leadership in rocket propulsion. To implement the National Rocket Propulsion Strategic Plan is to invest in the social, economic, and technological futures of America. The plan lays the basis for upgrading existing propulsion systems and a firm base for future full scale development, production, and operation of rocket propulsion systems for space, defense, and commercial applications.

  20. Surface Spectroscopy Center Of Excellence Project

    NASA Technical Reports Server (NTRS)

    Wooden, Diane

    2014-01-01

    We propose to develop a national center of excellence in Regolith Radiative Transfer (RRT), i.e., in modeling spectral reflectivity and emissivity of grainy or structured surfaces. The focus is the regime where the structural elements of grainy surfaces have grain sizes and separations of tens of microns, comparable to the wavelengths carrying diagnostic compositional information. This regime is of fundamental interest to remote sensing of planetary and terrestrial surfaces.

  1. Development of a Center for Teaching Excellence

    PubMed Central

    Andurkar, Shridhar; Sincak, Carrie; Todd, Timothy

    2010-01-01

    This article describes the development, implementation, and assessment of a Center for Teaching Excellence at Midwestern University Chicago College of Pharmacy. The purpose of the Center was to create a systematic framework to promote, enhance, and assess the scholarship of teaching and learning. Assessment of the Center's activities suggests a positive impact on the teaching abilities of faculty. This report is intended to offer other schools or colleges of pharmacy considerations for center development. PMID:21088728

  2. Gervais High School: 100% Committed to Excellence

    ERIC Educational Resources Information Center

    Principal Leadership, 2013

    2013-01-01

    Gervais High School--with a senior class of 80 and a total enrollment of 337--may be small in size compared to its neighbors, but it has demonstrated over the last four years the ability to think big in pursuit of excellence. A decade ago, Gervais had a well-earned reputation in Oregon's Willamette Valley as a drug-ridden, gang-infested…

  3. 2012 Editors' Citations for Excellence in Refereeing

    NASA Astrophysics Data System (ADS)

    2013-09-01

    One of the most important services performed for AGU is the conscientious reviewing of submitted papers. Because of the nature of the reviewing process, this service is also one of the least recognized. Every year editors are asked to select the outstanding reviewers from the previous year. The reviewers listed below have been cited by editors of AGU journals and Eos for excellence in refereeing. These individuals are to be commended for consistently providing constructive and thoughtful reviews.

  4. 2013 Editors' Citations for Excellence in Refereeing

    NASA Astrophysics Data System (ADS)

    2014-06-01

    One of the most important services performed for AGU is the conscientious reviewing of submitted papers. Because of the nature of the reviewing process, this service is also one of the least recognized. Every year editors are asked to select the outstanding reviewers from the previous year. The reviewers listed below have been cited by editors of AGU journals and Eos for excellence in refereeing. These individuals are to be commended for consistently providing constructive and thoughtful reviews.

  5. Role modeling excellence in clinical nursing practice.

    PubMed

    Perry, R N Beth

    2009-01-01

    Role modeling excellence in clinical nursing practice is the focus of this paper. The phenomenological research study reported involved a group of 8 nurses identified by their colleagues as exemplary. The major theme revealed in this study was that these exemplary nurses were also excellent role models in the clinical setting. This paper details approaches used by these nurses that made them excellent role models. Specifically, the themes of attending to the little things, making connections, maintaining a light-hearted attitude, modeling, and affirming others are presented. These themes are discussed within the framework of Watson [Watson, J., 1989. Human caring and suffering: a subjective model for health services. In: Watson, J., Taylor, R. (Eds.), They Shall Not Hurt: Human Suffering and Human Caring. Colorado University, Boulder, CO] "transpersonal caring" and [Bandura, A., 1997. Social Learning Theory. Prentice Hall, Englewood Cliffs, NJ] "Social Learning Theory." Particular emphasis in the discussion is on how positive role modeling by exemplary practitioners can contribute to the education of clinical nurses in the practice setting. PMID:18590978

  6. Comparison of simulation to absolute X-ray emission of CH plasma created with the Nike laser

    NASA Astrophysics Data System (ADS)

    Busquet, M.; Weaver, J. L.; Colombant, D. G.; Mostovych, A. N.; Feldman, U.; Klapisch, M.; Seely, J. F.; Holland, G.

    2006-06-01

    The Nike laser group at the Naval Research Laboratory has an ongoing effort to improve and benchmark the radiation hydrodynamic simulations used to develop pellet designs for inertial confinement fusion. A new postprocessor, Virtual Spectro, has been added to the FAST code suite for detailed simulation of non-LTE spectra, including radiation transport effects and Stark line profile. This new combination enhances our ability to predict the absolute emission of soft x-rays. An absolutely calibrated transmission grating spectrometer and a high resolution grazing incidence spectrometer have been used to collect time integrated and time resolved spectra emitted by CH targets irradiated at laser intensities of ˜10 TW/cm^2. Comparison between these observations and simulations using Virtual Spectro demonstrates excellent agreement (within factor of ˜1.5) for the absolute emission.

  7. Non-invasive quantification of brain glycogen absolute concentration

    PubMed Central

    van Heeswijk, Ruud B.; Xin, Lijing; Laus, Sabrina; Frenkel, Hanne; Lei, Hongxia; Gruetter, Rolf

    2009-01-01

    The only currently available method to measure brain glycogen in vivo is 13C NMR spectroscopy. Incorporation of 13C-labeled glucose (Glc) is necessary to allow glycogen measurement, but might be affected by turnover changes. Our aim was to measure glycogen absolute concentration in the rat brain by eliminating label turnover as variable. The approach is based on establishing an increased, constant 13C isotopic enrichment (IE). 13C-Glc infusion is then performed at the IE of brain glycogen. As glycogen IE cannot be assessed in vivo, we validated that it can be inferred from that of N-acetyl-aspartate IE in vivo: After [1-13C]-Glc ingestion, glycogen IE was 2.2 ± 0.1 fold that of N-acetyl-aspartate (n = 11, R2 = 0.77). After subsequent Glc infusion, glycogen IE equaled brain Glc IE (n = 6, paired t-test, p = 0.37), implying isotopic steady-state achievement and complete turnover of the glycogen molecule. Glycogen concentration measured in vivo by 13C NMR (mean ± SD: 5.8 ± 0.7 μmol/g) was in excellent agreement with that in vitro (6.4 ± 0.6 μmol/g, n = 5). When insulin was administered, the stability of glycogen concentration was analogous to previous biochemical measurements implying that glycogen turnover is activated by insulin. We conclude that the entire glycogen molecule is turned over and that insulin activates glycogen turnover. PMID:19013831

  8. Gyrokinetic Statistical Absolute Equilibrium and Turbulence

    SciTech Connect

    Jian-Zhou Zhu and Gregory W. Hammett

    2011-01-10

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence [T.-D. Lee, "On some statistical properties of hydrodynamical and magnetohydrodynamical fields," Q. Appl. Math. 10, 69 (1952)] is taken to study gyrokinetic plasma turbulence: A finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N + 1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  9. Absolute surface energy for zincblende semiconductors

    NASA Astrophysics Data System (ADS)

    Zhang, S. B.; Wei, Su-Huai

    2003-03-01

    Recent advance in nanosciences requires the determination of surface (or facet) energy of semiconductors, which is often difficult due to the polar nature of some of the most important surfaces such as the (111)A/(111)B surfaces. Several approaches have been developed in the past [1-3] to deal with the problem but an unambiguous division of the polar surface energies is yet to come [2]. Here we show that an accurate division is indeed possible for the zincblende semiconductors and will present the results for GaAs, ZnSe, and CuInSe2 [4], respectively. A general trend emerges, relating the absolute surface energy to the ionicity of the bulk materials. [1] N. Chetty and R. M. Martin, Phys. Rev. B 45, 6074 (1992). [2] N. Moll, et al., Phys. Rev. B 54, 8844 (1996). [3] S. Mankefors, Phys. Rev. B 59, 13151 (1999). [4] S. B. Zhang and S.-H. Wei, Phys. Rev. B 65, 081402 (2002).

  10. Climate Absolute Radiance and Refractivity Observatory (CLARREO)

    NASA Technical Reports Server (NTRS)

    Leckey, John P.

    2015-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is a mission, led and developed by NASA, that will measure a variety of climate variables with an unprecedented accuracy to quantify and attribute climate change. CLARREO consists of three separate instruments: an infrared (IR) spectrometer, a reflected solar (RS) spectrometer, and a radio occultation (RO) instrument. The mission will contain orbiting radiometers with sufficient accuracy, including on orbit verification, to calibrate other space-based instrumentation, increasing their respective accuracy by as much as an order of magnitude. The IR spectrometer is a Fourier Transform spectrometer (FTS) working in the 5 to 50 microns wavelength region with a goal of 0.1 K (k = 3) accuracy. The FTS will achieve this accuracy using phase change cells to verify thermistor accuracy and heated halos to verify blackbody emissivity, both on orbit. The RS spectrometer will measure the reflectance of the atmosphere in the 0.32 to 2.3 microns wavelength region with an accuracy of 0.3% (k = 2). The status of the instrumentation packages and potential mission options will be presented.

  11. Absolute decay width measurements in 16O

    NASA Astrophysics Data System (ADS)

    Wheldon, C.; Ashwood, N. I.; Barr, M.; Curtis, N.; Freer, M.; Kokalova, Tz; Malcolm, J. D.; Spencer, S. J.; Ziman, V. A.; Faestermann, Th; Krücken, R.; Wirth, H.-F.; Hertenberger, R.; Lutter, R.; Bergmaier, A.

    2012-09-01

    The reaction 126C(63Li, d)168O* at a 6Li bombarding energy of 42 MeV has been used to populate excited states in 16O. The deuteron ejectiles were measured using the high-resolution Munich Q3D spectrograph. A large-acceptance silicon-strip detector array was used to register the recoil and break-up products. This complete kinematic set-up has enabled absolute α-decay widths to be measured with high-resolution in the 13.9 to 15.9 MeV excitation energy regime in 16O; many for the first time. This energy region spans the 14.4 MeV four-α breakup threshold. Monte-Carlo simulations of the detector geometry and break-up processes yield detection efficiencies for the two dominant decay modes of 40% and 37% for the α+12C(g.s.) and a+12C(2+1) break-up channels respectively.

  12. Absolute calibration of forces in optical tweezers

    NASA Astrophysics Data System (ADS)

    Dutra, R. S.; Viana, N. B.; Maia Neto, P. A.; Nussenzveig, H. M.

    2014-07-01

    Optical tweezers are highly versatile laser traps for neutral microparticles, with fundamental applications in physics and in single molecule cell biology. Force measurements are performed by converting the stiffness response to displacement of trapped transparent microspheres, employed as force transducers. Usually, calibration is indirect, by comparison with fluid drag forces. This can lead to discrepancies by sizable factors. Progress achieved in a program aiming at absolute calibration, conducted over the past 15 years, is briefly reviewed. Here we overcome its last major obstacle, a theoretical overestimation of the peak stiffness, within the most employed range for applications, and we perform experimental validation. The discrepancy is traced to the effect of primary aberrations of the optical system, which are now included in the theory. All required experimental parameters are readily accessible. Astigmatism, the dominant effect, is measured by analyzing reflected images of the focused laser spot, adapting frequently employed video microscopy techniques. Combined with interface spherical aberration, it reveals a previously unknown window of instability for trapping. Comparison with experimental data leads to an overall agreement within error bars, with no fitting, for a broad range of microsphere radii, from the Rayleigh regime to the ray optics one, for different polarizations and trapping heights, including all commonly employed parameter domains. Besides signaling full first-principles theoretical understanding of optical tweezers operation, the results may lead to improved instrument design and control over experiments, as well as to an extended domain of applicability, allowing reliable force measurements, in principle, from femtonewtons to nanonewtons.

  13. Absolute spectrophotometry of northern compact planetary nebulae

    NASA Astrophysics Data System (ADS)

    Wright, S. A.; Corradi, R. L. M.; Perinotto, M.

    2005-06-01

    We present medium-dispersion spectra and narrowband images of six northern compact planetary nebulae (PNe): BoBn 1, DdDm 1, IC 5117, M 1-5, M 1-71, and NGC 6833. From broad-slit spectra, total absolute fluxes and equivalent widths were measured for all observable emission lines. High signal-to-noise emission line fluxes of Hα, Hβ, [Oiii], [Nii], and HeI may serve as emission line flux standards for northern hemisphere observers. From narrow-slit spectra, we derive systemic radial velocities. For four PNe, available emission line fluxes were measured with sufficient signal-to-noise to probe the physical properties of their electron densities, temperatures, and chemical abundances. BoBn 1 and DdDm 1, both type IV PNe, have an Hβ flux over three sigma away from previous measurements. We report the first abundance measurements of M 1-71. NGC 6833 measured radial velocity and galactic coordinates suggest that it is associated with the outer arm or possibly the galactic halo, and its low abundance ([O/H]=1.3× 10-4) may be indicative of low metallicity within that region.

  14. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOEpatents

    Prasad, Mano K.; Snyderman, Neal J.; Rowland, Mark S.

    2015-12-01

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  15. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  16. Using humor to communicate competitive excellence

    SciTech Connect

    Grimsley, M.

    1994-12-31

    The use of humor to communicate excellence in the nuclear industry is described, particularly as a method to relieve public anxiety. At many companies throughout our culture, it is not okay to have fun with anything work related; it violates the puritan work ethic - you know, nose to the grindstone, buckle down and get crackin, and so forth. At Wolf Creek, we`re finding that when we have fun - not only among ourselves, but around and with others as well - we are more effective with the public, more interesting to the media, and we all smile more.

  17. Graphing techniques for materials laboratory using Excel

    NASA Technical Reports Server (NTRS)

    Kundu, Nikhil K.

    1994-01-01

    Engineering technology curricula stress hands on training and laboratory practices in most of the technical courses. Laboratory reports should include analytical as well as graphical evaluation of experimental data. Experience shows that many students neither have the mathematical background nor the expertise for graphing. This paper briefly describes the procedure and data obtained from a number of experiments such as spring rate, stress concentration, endurance limit, and column buckling for a variety of materials. Then with a brief introduction to Microsoft Excel the author explains the techniques used for linear regression and logarithmic graphing.

  18. The absolute disparity anomaly and the mechanism of relative disparities.

    PubMed

    Chopin, Adrien; Levi, Dennis; Knill, David; Bavelier, Daphne

    2016-06-01

    There has been a long-standing debate about the mechanisms underlying the perception of stereoscopic depth and the computation of the relative disparities that it relies on. Relative disparities between visual objects could be computed in two ways: (a) using the difference in the object's absolute disparities (Hypothesis 1) or (b) using relative disparities based on the differences in the monocular separations between objects (Hypothesis 2). To differentiate between these hypotheses, we measured stereoscopic discrimination thresholds for lines with different absolute and relative disparities. Participants were asked to judge the depth of two lines presented at the same distance from the fixation plane (absolute disparity) or the depth between two lines presented at different distances (relative disparity). We used a single stimulus method involving a unique memory component for both conditions, and no extraneous references were available. We also measured vergence noise using Nonius lines. Stereo thresholds were substantially worse for absolute disparities than for relative disparities, and the difference could not be explained by vergence noise. We attribute this difference to an absence of conscious readout of absolute disparities, termed the absolute disparity anomaly. We further show that the pattern of correlations between vergence noise and absolute and relative disparity acuities can be explained jointly by the existence of the absolute disparity anomaly and by the assumption that relative disparity information is computed from absolute disparities (Hypothesis 1). PMID:27248566

  19. The absolute disparity anomaly and the mechanism of relative disparities

    PubMed Central

    Chopin, Adrien; Levi, Dennis; Knill, David; Bavelier, Daphne

    2016-01-01

    There has been a long-standing debate about the mechanisms underlying the perception of stereoscopic depth and the computation of the relative disparities that it relies on. Relative disparities between visual objects could be computed in two ways: (a) using the difference in the object's absolute disparities (Hypothesis 1) or (b) using relative disparities based on the differences in the monocular separations between objects (Hypothesis 2). To differentiate between these hypotheses, we measured stereoscopic discrimination thresholds for lines with different absolute and relative disparities. Participants were asked to judge the depth of two lines presented at the same distance from the fixation plane (absolute disparity) or the depth between two lines presented at different distances (relative disparity). We used a single stimulus method involving a unique memory component for both conditions, and no extraneous references were available. We also measured vergence noise using Nonius lines. Stereo thresholds were substantially worse for absolute disparities than for relative disparities, and the difference could not be explained by vergence noise. We attribute this difference to an absence of conscious readout of absolute disparities, termed the absolute disparity anomaly. We further show that the pattern of correlations between vergence noise and absolute and relative disparity acuities can be explained jointly by the existence of the absolute disparity anomaly and by the assumption that relative disparity information is computed from absolute disparities (Hypothesis 1). PMID:27248566

  20. Self-scheduling with Microsoft Excel.

    PubMed

    Irvin, S A; Brown, H N

    1999-01-01

    Excessive time was being spent by the emergency department (ED) staff, head nurse, and unit secretary on a complex 6-week manual self-scheduling system. This issue, plus inevitable errors and staff dissatisfaction, resulted in a manager-lead initiative to automate elements of the scheduling process using Microsoft Excel. The implementation of this initiative included: common coding of all 8-hour and 12-hour shifts, with each 4-hour period represented by a cell; the creation of a 6-week master schedule using the "count-if" function of Excel based on current staffing guidelines; staff time-off requests then entered by the department secretary; the head nurse, with staff input, then fine-tuned the schedule to provide even unit coverage. Outcomes of these changes included an increase in staff satisfaction, time saved by the head nurse, and staff work time saved because there was less arguing about the schedule. Ultimately, the automated self-scheduling method was expanded to the entire 700-bed hospital. PMID:10711163

  1. Orion Absolute Navigation System Progress and Challenge

    NASA Technical Reports Server (NTRS)

    Holt, Greg N.; D'Souza, Christopher

    2012-01-01

    The absolute navigation design of NASA's Orion vehicle is described. It has undergone several iterations and modifications since its inception, and continues as a work-in-progress. This paper seeks to benchmark the current state of the design and some of the rationale and analysis behind it. There are specific challenges to address when preparing a timely and effective design for the Exploration Flight Test (EFT-1), while still looking ahead and providing software extensibility for future exploration missions. The primary onboard measurements in a Near-Earth or Mid-Earth environment consist of GPS pseudo-range and delta-range, but for future explorations missions the use of star-tracker and optical navigation sources need to be considered. Discussions are presented for state size and composition, processing techniques, and consider states. A presentation is given for the processing technique using the computationally stable and robust UDU formulation with an Agee-Turner Rank-One update. This allows for computational savings when dealing with many parameters which are modeled as slowly varying Gauss-Markov processes. Preliminary analysis shows up to a 50% reduction in computation versus a more traditional formulation. Several state elements are discussed and evaluated, including position, velocity, attitude, clock bias/drift, and GPS measurement biases in addition to bias, scale factor, misalignment, and non-orthogonalities of the accelerometers and gyroscopes. Another consideration is the initialization of the EKF in various scenarios. Scenarios such as single-event upset, ground command, and cold start are discussed as are strategies for whole and partial state updates as well as covariance considerations. Strategies are given for dealing with latent measurements and high-rate propagation using multi-rate architecture. The details of the rate groups and the data ow between the elements is discussed and evaluated.

  2. Evaluation of the Absolute Regional Temperature Potential

    NASA Technical Reports Server (NTRS)

    Shindell, D. T.

    2012-01-01

    The Absolute Regional Temperature Potential (ARTP) is one of the few climate metrics that provides estimates of impacts at a sub-global scale. The ARTP presented here gives the time-dependent temperature response in four latitude bands (90-28degS, 28degS-28degN, 28-60degN and 60-90degN) as a function of emissions based on the forcing in those bands caused by the emissions. It is based on a large set of simulations performed with a single atmosphere-ocean climate model to derive regional forcing/response relationships. Here I evaluate the robustness of those relationships using the forcing/response portion of the ARTP to estimate regional temperature responses to the historic aerosol forcing in three independent climate models. These ARTP results are in good accord with the actual responses in those models. Nearly all ARTP estimates fall within +/-20%of the actual responses, though there are some exceptions for 90-28degS and the Arctic, and in the latter the ARTP may vary with forcing agent. However, for the tropics and the Northern Hemisphere mid-latitudes in particular, the +/-20% range appears to be roughly consistent with the 95% confidence interval. Land areas within these two bands respond 39-45% and 9-39% more than the latitude band as a whole. The ARTP, presented here in a slightly revised form, thus appears to provide a relatively robust estimate for the responses of large-scale latitude bands and land areas within those bands to inhomogeneous radiative forcing and thus potentially to emissions as well. Hence this metric could allow rapid evaluation of the effects of emissions policies at a finer scale than global metrics without requiring use of a full climate model.

  3. Absolute optical surface measurement with deflectometry

    NASA Astrophysics Data System (ADS)

    Li, Wansong; Sandner, Marc; Gesierich, Achim; Burke, Jan

    Deflectometry utilises the deformation and displacement of a sample pattern after reflection from a test surface to infer the surface slopes. Differentiation of the measurement data leads to a curvature map, which is very useful for surface quality checks with sensitivity down to the nanometre range. Integration of the data allows reconstruction of the absolute surface shape, but the procedure is very error-prone because systematic errors may add up to large shape deviations. In addition, there are infinitely many combinations for slope and object distance that satisfy a given observation. One solution for this ambiguity is to include information on the object's distance. It must be known very accurately. Two laser pointers can be used for positioning the object, and we also show how a confocal chromatic distance sensor can be used to define a reference point on a smooth surface from which the integration can be started. The used integration algorithm works without symmetry constraints and is therefore suitable for free-form surfaces as well. Unlike null testing, deflectometry also determines radius of curvature (ROC) or focal lengths as a direct result of the 3D surface reconstruction. This is shown by the example of a 200 mm diameter telescope mirror, whose ROC measurements by coordinate measurement machine and deflectometry coincide to within 0.27 mm (or a sag error of 1.3μm). By the example of a diamond-turned off-axis parabolic mirror, we demonstrate that the figure measurement uncertainty comes close to a well-calibrated Fizeau interferometer.

  4. Absolute determination of local tropospheric OH concentrations

    NASA Technical Reports Server (NTRS)

    Armerding, Wolfgang; Comes, Franz-Josef

    1994-01-01

    Long path absorption (LPA) according to Lambert Beer's law is a method to determine absolute concentrations of trace gases such as tropospheric OH. We have developed a LPA instrument which is based on a rapid tuning of the light source which is a frequency doubled dye laser. The laser is tuned across two or three OH absorption features around 308 nm with a scanning speed of 0.07 cm(exp -1)/microsecond and a repetition rate of 1.3 kHz. This high scanning speed greatly reduces the fluctuation of the light intensity caused by the atmosphere. To obtain the required high sensitivity the laser output power is additionally made constant and stabilized by an electro-optical modulator. The present sensitivity is of the order of a few times 10(exp 5) OH per cm(exp 3) for an acquisition time of a minute and an absorption path length of only 1200 meters so that a folding of the optical path in a multireflection cell was possible leading to a lateral dimension of the cell of a few meters. This allows local measurements to be made. Tropospheric measurements have been carried out in 1991 resulting in the determination of OH diurnal variation at specific days in late summer. Comparison with model calculations have been made. Interferences are mainly due to SO2 absorption. The problem of OH self generation in the multireflection cell is of minor extent. This could be shown by using different experimental methods. The minimum-maximum signal to noise ratio is about 8 x 10(exp -4) for a single scan. Due to the small size of the absorption cell the realization of an open air laboratory is possible in which by use of an additional UV light source or by additional fluxes of trace gases the chemistry can be changed under controlled conditions allowing kinetic studies of tropospheric photochemistry to be made in open air.

  5. Absolute Radiometric Calibration of KOMPSAT-3A

    NASA Astrophysics Data System (ADS)

    Ahn, H. Y.; Shin, D. Y.; Kim, J. S.; Seo, D. C.; Choi, C. U.

    2016-06-01

    This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A) performed by the Korea Aerospace Research Institute (KARI) and the Pukyong National University Remote Sensing Group (PKNU RSG) in 2015.The primary stages of this study are summarized as follows: (1) A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2) To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4). Correlations between top-of-atmosphere (TOA) radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB) region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  6. Results of the first North American comparison of absolute gravimeters, NACAG-2010

    USGS Publications Warehouse

    Schmerge, David; Francis, Olvier; Henton, J.; Ingles, D.; Jones, D.; Kennedy, Jeffrey R.; Krauterbluth, K.; Liard, J.; Newell, D.; Sands, R.; Schiel, J.; Silliker, J.; van Westrum, D.

    2012-01-01

    The first North American Comparison of absolute gravimeters (NACAG-2010) was hosted by the National Oceanic and Atmospheric Administration at its newly renovated Table Mountain Geophysical Observatory (TMGO) north of Boulder, Colorado, in October 2010. NACAG-2010 and the renovation of TMGO are part of NGS’s GRAV-D project (Gravity for the Redefinition of the American Vertical Datum). Nine absolute gravimeters from three countries participated in the comparison. Before the comparison, the gravimeter operators agreed to a protocol describing the strategy to measure, calculate, and present the results. Nine sites were used to measure the free-fall acceleration of g. Each gravimeter measured the value of g at a subset of three of the sites, for a total set of 27 g-values for the comparison. The absolute gravimeters agree with one another with a standard deviation of 1.6 µGal (1 Gal = 1 cm s-2). The minimum and maximum offsets are -2.8 and 2.7 µGal. This is an excellent agreement and can be attributed to multiple factors, including gravimeters that were in good working order, good operators, a quiet observatory, and a short duration time for the experiment. These results can be used to standardize gravity surveys internationally.

  7. Organizational Cultures of Excellent Schools in Hong Kong.

    ERIC Educational Resources Information Center

    Pang, Nicholas Sun-Keung

    Currently school organizations are under pressure to achieve excellence. There is no exception to this pressure in the schools of Hong Kong. Research into organizational cultures of excellent schools in Hong Kong is seeking evidence for others striving for excellence. Excellent schools are defined as few schools that have many aspects that…

  8. Mid-infrared absolute spectral responsivity scale based on an absolute cryogenic radiometer and an optical parametric oscillator laser

    NASA Astrophysics Data System (ADS)

    Zhao, Kun; Shi, Xueshun; Chen, Haidong; Liu, Yulong; Liu, Changming; Chen, Kunfeng; Li, Ligong; Gan, Haiyong; Ma, Chong

    2016-06-01

    We are reporting on a laser-based absolute spectral responsivity scale in the mid-infrared spectral range. By using a mid-infrared tunable optical parametric oscillator as the laser source, the absolute responsivity scale has been established by calibrating thin-film thermopile detectors against an absolute cryogenic radiometer. The thin-film thermopile detectors can be then used as transfer standard detectors. The extended uncertainty of the absolute spectral responsivity measurement has been analyzed to be 0.58%–0.68% (k  =  2).

  9. Simplifying CEA through Excel, VBA, and Subeq

    NASA Technical Reports Server (NTRS)

    Foster, Ryan

    2004-01-01

    Many people use compound equilibrium programs for very different reasons, varying from refrigerators to light bulbs to rockets. A commonly used equilibrium program is CEA. CEA can take various inputs such as pressure, temperature, and volume along with numerous reactants and run them through equilibrium equations to obtain valuable output information, including products formed and their relative amounts. A little over a year ago, Bonnie McBride created the program subeq with the goal to simplify the calling of CEA. Subeq was also designed to be called by other programs, including Excel, through the use of Visual Basic for Applications (VBA). The largest advantage of using Excel is that it allows the user to input the information in a colorful and user-friendly environment while allowing VBA to run subeq, which is in the form of a FORTRAN DLL (Dynamic Link Library). Calling subeq in this form makes it much faster than if it were converted to VBA. Since subeq requires such large lists of reactant and product names, all of which can't be passed in as an array, subeq had to be changed to accept very long strings of reactants and products. To pass this string and adjust the transfer of input and output parameters, the subeq DLL had to be changed. One program that does this is Compaq Visual FORTRAN, which allows DLLs to be edited, debugged, and compiled. Compaq Visual FORTRAN uses FORTRAN 90/95, which has additional features to that of FORTRAN 77. My goals this summer include finishing up the excel spreadsheet of subeq, which I started last summer, and putting it on the Internet so that others can use it without having to download my spreadsheet. To finish up the spreadsheet I will need to work on debugging current options and problems. I will also work on making it as robust as possible, so that all errors that may arise will be clearly communicated to the user. New features will be added old ones will be changed as I receive comments from people using the spreadsheet

  10. BREEAM Excellent: Business Value Vs Employee Morale

    NASA Astrophysics Data System (ADS)

    Turner, Nova; Arif, Mohammed

    2012-05-01

    BREEAM is gaining popularity in the UK. Similar green building standards have gained popularity worldwide. However, it is important that we analyse the actual value added to a business by having a BREEAM rated facility. It is also important to analyze the impact on employee performance of such a facility. This paper presents a case study of a BREEAM excellent rated building with impact on the morale and performance of the employees. The data for the paper was collected using semi-structured interviews of a group of employees who work at this facility located in Glasgow. The results suggest that it is important to highlight the tangible benefits and value added through the implementation of the BREEAM standard.

  11. [EXCELLENCE IN QUALITY, SERVICE AND RESEARCH].

    PubMed

    Hershko, Alon; Edri, Mira Maram; Wirtheim, Eytan

    2015-08-01

    Meir Medical Center was founded in 1956 as a hospital for patients with tuberculosis and lung disease. In 1962 its status was changed to a general hospital. Since 1971 it has been academically affiliated with the Tel Aviv University. Presently, Meir is a leading institution with regards to medical leadership. The strategic goals of the Meir Medical Center have been defined as excellence in care quality, service and research. In terms of scientific activity, the institutional Research Authority has been involved in strengthening the scientific community. This has been achieved through various initiatives including research grants, annual scientific meetings, development of infrastructure as well as a long term strategy for the promotion of academic research. Here we outline major recent progress in the implementation of quality control indices and improved patient experience. Furthermore, this issue of Harefuah highlights the hospital's multifaceted accomplishments in the clinical and academic fields. PMID:26480608

  12. Profiling 'centres of excellence' in CAM research.

    PubMed

    Hentschel, C

    2002-03-01

    Several 'centres of excellence' of research in complementary/alternative medicine (CAM) have emerged in recent years. This study represents an attempt to profile the most productive of these centres. Medline searches (1995-2001) were performed with a long list of individuals directing CAM research groups as key words. Eight of them (all male) had published in excess of 20 Medline-listed articles between 1995-2001, and this group was evaluated in further detail. Three originated from the US and two from the UK. Collectively this group had published 32 clinical trials, an equal number of surveys and 95 systematic reviews. The range of research subjects for most centres was narrow. It is concluded that several active CAM research centres are well established. Their output is variable and, in most cases, leave room for improvement. Probably because of funding difficulties, clinical trials remain rare. PMID:12442823

  13. Center of Excellence in Theoretical Geoplasma Research

    NASA Astrophysics Data System (ADS)

    Chang, Tom

    1993-08-01

    The Center for Theoretical Geoplasma Physics was established at MIT in 1986 through an AFOSR University Research Initiative grant. The goal of the Center since its inception has been to develop and maintain a program of excellence in interdisciplinary geoplasma research involving the mutual interaction of ionospheric scientists, aeronomists, plasma physicists, and numerical analysts. During the past six years, members of the center have made germinal contributions to a number of definitive research findings in the fundamental understanding of ionospheric turbulence, particle acceleration, and the phenomenon of coupling between the ionosphere and magnetosphere. Some of the results of these research activities have already found practical applications toward the mission of the Air Force by scientists at the Geophysics Directorate of the Phillips Laboratory, particularly those affiliated with the research group headed by Dr. J.R. Jasperse of the Ionospheric Effects Branch. Theoretical geoplasma physics, URI Program.

  14. Center-of-Excellence: Microlaser microscope

    NASA Astrophysics Data System (ADS)

    Webb, R. H.

    This Center-of-Excellence grant has supported the development of an imaging system based on microlaser arrays. In the second year of the grant, we dealt with the slow delivery of new microlaser arrays by developing a new approach to the idea of all-solid-state confocal microscopy. One solution was moderately successful, and the other has produced the first microscope that is electronically switchable from confocal to non-confocal. We think this may be a useful alternative to the final design. This report thus discloses patentable material. We describe first the central Microlaser Microscope project, then we will touch briefly on the other projects of the Center. The publications are primarily those of the smaller projects, though no longer exclusively so. The appendix includes some of the publications.

  15. Supplementary and Enrichment Series: Absolute Value. Teachers' Commentary. SP-25.

    ERIC Educational Resources Information Center

    Bridgess, M. Philbrick, Ed.

    This is one in a series of manuals for teachers using SMSG high school supplementary materials. The pamphlet includes commentaries on the sections of the student's booklet, answers to the exercises, and sample test questions. Topics covered include addition and multiplication in terms of absolute value, graphs of absolute value in the Cartesian…

  16. Supplementary and Enrichment Series: Absolute Value. SP-24.

    ERIC Educational Resources Information Center

    Bridgess, M. Philbrick, Ed.

    This is one in a series of SMSG supplementary and enrichment pamphlets for high school students. This series is designed to make material for the study of topics of special interest to students readily accessible in classroom quantity. Topics covered include absolute value, addition and multiplication in terms of absolute value, graphs of absolute…

  17. Novalis' Poetic Uncertainty: A "Bildung" with the Absolute

    ERIC Educational Resources Information Center

    Mika, Carl

    2016-01-01

    Novalis, the Early German Romantic poet and philosopher, had at the core of his work a mysterious depiction of the "absolute." The absolute is Novalis' name for a substance that defies precise knowledge yet calls for a tentative and sensitive speculation. How one asserts a truth, represents an object, and sets about encountering things…

  18. Absolute Humidity and the Seasonality of Influenza (Invited)

    NASA Astrophysics Data System (ADS)

    Shaman, J. L.; Pitzer, V.; Viboud, C.; Grenfell, B.; Goldstein, E.; Lipsitch, M.

    2010-12-01

    Much of the observed wintertime increase of mortality in temperate regions is attributed to seasonal influenza. A recent re-analysis of laboratory experiments indicates that absolute humidity strongly modulates the airborne survival and transmission of the influenza virus. Here we show that the onset of increased wintertime influenza-related mortality in the United States is associated with anomalously low absolute humidity levels during the prior weeks. We then use an epidemiological model, in which observed absolute humidity conditions temper influenza transmission rates, to successfully simulate the seasonal cycle of observed influenza-related mortality. The model results indicate that direct modulation of influenza transmissibility by absolute humidity alone is sufficient to produce this observed seasonality. These findings provide epidemiological support for the hypothesis that absolute humidity drives seasonal variations of influenza transmission in temperate regions. In addition, we show that variations of the basic and effective reproductive numbers for influenza, caused by seasonal changes in absolute humidity, are consistent with the general timing of pandemic influenza outbreaks observed for 2009 A/H1N1 in temperate regions. Indeed, absolute humidity conditions correctly identify the region of the United States vulnerable to a third, wintertime wave of pandemic influenza. These findings suggest that the timing of pandemic influenza outbreaks is controlled by a combination of absolute humidity conditions, levels of susceptibility and changes in population mixing and contact rates.

  19. 2005 College Astronomy Teaching Excellence Workshops

    NASA Astrophysics Data System (ADS)

    Prather, E. E.; Slater, T. F.; Greene, W. M.; Thaller, M.; Brissenden, G.; UA Steward Observatory CAPER Team; NASA JPL Navigator EPO CenterAstrononomy Education Team; NASA Spitzer EPO Team

    2004-12-01

    As part of the education and public outreach efforts of the NASA JPL Navigator and Spitzer EPO Programs along with the American Astronomical Society and the Astronomical Society of the Pacific, astronomy educators affiliated with the Conceptual Astronomy and Physics Education Research (CAPER) Team at the University of Arizona are conducting a series of two- and three-day teaching excellence workshops for college faculty. These regional workshops are being held at community colleges around the country and in conjunction with professional society meetings, such as the American Astronomical Society and the American Association of Physics Teachers, and through the infrastructure of the National Science Foundation's Summer Chautauqua Workshop program. These interactive teaching excellence workshops focus on dilemmas astronomy teachers face and develop practical solutions for the troubling issues in curriculum, instruction, and assessment. After reviewing the latest research about how students learn, participants define and set measurable student learning goals and objectives for students in their astronomy courses and construct effective course syllabi reflecting the ASTRO 101 goals publicized by the AAS. To improve instruction, participants learn how to create productive learning environments by using interactive lectures, peer instruction, engaging demonstrations, collaborative groups, tutorials, computer-based laboratories, and observational projects. Participants also learn how to write more effective multiple-choice tests and implement authentic assessment strategies including portfolio assessment, performance tasks, and concept maps. Texts used at the workshop include: (i) Learner-Centered Astronomy Teaching, Slater and Adams, Prentice Hall, 2002; (ii) Great Ideas for Teaching Astronomy, Pompea, Brooks Cole, 2000; Insights into the Universe, Slater and Zeilik, and (iv) Lecture-Tutorials for Introductory Astronomy, Adams, Prather, & Slater, Prentice Hall, 2005.

  20. Explorations in the Meanings of Excellence and Its Importance for Counselors: The Culture of Excellence in the United States

    ERIC Educational Resources Information Center

    Stewart, Alan E.

    2010-01-01

    Contemporary narratives of excellence embody the competitive striving and achievement themes underlying the idea of American exceptionalism. The author examines excellence through Aristotle's (trans. 2002) "Nicomachean Ethics". An overemphasis on winning or excelling can undermine general human excellence and harm well-being. Counselors are…

  1. Karst Water System Investigated by Absolute Gravimetry

    NASA Astrophysics Data System (ADS)

    Quinif, Y.; Meus, P.; van Camp, M.; Kaufmann, O.; van Ruymbeke, M.; Vandiepenbeeck, M.; Camelbeeck, T.

    2006-12-01

    The highly anisotropic and heterogeneous hydrogeological characteristics of karst aquifers are difficult to characterize and present challenges for modeling of storage capacities. Little is known about the surface and groundwater interconnection, about the connection between the porous formations and the draining cave and conduits, and about the variability of groundwater volume within the system. Usually, an aquifer is considered as a black box, where water fluxes are monitored as input and output. However, water inflow and outflow are highly variable and cannot be measured directly. A recent project, begun in 2006 sought to constrain the water budget in a Belgian karst aquifer and to assess the porosity and water dynamics, combining absolute gravity (AG) measurements and piezometric levels around the Rochefort cave. The advantage of gravity measurements is that they integrate all the subsystems in the karst system. This is not the case with traditional geophysical tools like boring or monitoring wells, which are soundings affected by their near environment and its heterogeneity. The investigated cave results from the meander cutoff system of the Lomme River. The main inputs are swallow holes of the river crossing the limestone massif. The river is canalized and the karst system is partly disconnected from the hydraulic system. In February and March 2006, when the river spilled over its dyke and sank into the most important swallow hole, this resulted in dramatic and nearly instantaneous increases in the piezometric levels in the cave, reaching up to 13 meters. Meanwhile, gravity increased by 50 and 90 nms-2 in February and March, respectively. A first conclusion is that during these sudden floods, the pores and fine fissures were poorly connected with the enlarged fractures, cave, and conduits. With a rise of 13 meters in the water level and a 5% porosity, a gravity change of 250 nms-2 should have been expected. This moderate gravity variation suggests either a

  2. Absolute radiometric calibration of advanced remote sensing systems

    NASA Technical Reports Server (NTRS)

    Slater, P. N.

    1982-01-01

    The distinction between the uses of relative and absolute spectroradiometric calibration of remote sensing systems is discussed. The advantages of detector-based absolute calibration are described, and the categories of relative and absolute system calibrations are listed. The limitations and problems associated with three common methods used for the absolute calibration of remote sensing systems are addressed. Two methods are proposed for the in-flight absolute calibration of advanced multispectral linear array systems. One makes use of a sun-illuminated panel in front of the sensor, the radiance of which is monitored by a spectrally flat pyroelectric radiometer. The other uses a large, uniform, high-radiance reference ground surface. The ground and atmospheric measurements required as input to a radiative transfer program to predict the radiance level at the entrance pupil of the orbital sensor are discussed, and the ground instrumentation is described.

  3. Testing the quasi-absolute method in photon activation analysis

    SciTech Connect

    Sun, Z. J.; Wells, D.; Starovoitova, V.; Segebade, C.

    2013-04-19

    In photon activation analysis (PAA), relative methods are widely used because of their accuracy and precision. Absolute methods, which are conducted without any assistance from calibration materials, are seldom applied for the difficulty in obtaining photon flux in measurements. This research is an attempt to perform a new absolute approach in PAA - quasi-absolute method - by retrieving photon flux in the sample through Monte Carlo simulation. With simulated photon flux and database of experimental cross sections, it is possible to calculate the concentration of target elements in the sample directly. The QA/QC procedures to solidify the research are discussed in detail. Our results show that the accuracy of the method for certain elements is close to a useful level in practice. Furthermore, the future results from the quasi-absolute method can also serve as a validation technique for experimental data on cross sections. The quasi-absolute method looks promising.

  4. Learning in the temporal bisection task: Relative or absolute?

    PubMed

    de Carvalho, Marilia Pinheiro; Machado, Armando; Tonneau, François

    2016-01-01

    We examined whether temporal learning in a bisection task is absolute or relational. Eight pigeons learned to choose a red key after a t-seconds sample and a green key after a 3t-seconds sample. To determine whether they had learned a relative mapping (short→Red, long→Green) or an absolute mapping (t-seconds→Red, 3t-seconds→Green), the pigeons then learned a series of new discriminations in which either the relative or the absolute mapping was maintained. Results showed that the generalization gradient obtained at the end of a discrimination predicted the pattern of choices made during the first session of a new discrimination. Moreover, most acquisition curves and generalization gradients were consistent with the predictions of the learning-to-time model, a Spencean model that instantiates absolute learning with temporal generalization. In the bisection task, the basis of temporal discrimination seems to be absolute, not relational. PMID:26752233

  5. A Vision of Excellence. The National Search for Excellence Awards in Rehabilitation

    ERIC Educational Resources Information Center

    J.M. Foundation, New York, NY.

    This publication provides information on 1989 winners of the Search for Excellence award for outstanding vocational service programs for people with disabilities. A history and description of the search appears first. A winner and two finalists are described in each of four categories. An introduction to each category discusses typical applicant…

  6. Learning Excellence: How Do Learning Providers Measure Up to the Benchmarks of Service Excellence?

    ERIC Educational Resources Information Center

    Owen, Jane; Robson, Andy; Yarrow, Dave; Appleby, Alex

    In order for learning providers to become learning organizations, their services must be delivered effectively. The Learning PROBE (Promoting Business Excellence) was created for the learning and skills sector and was in use by nearly 100 colleges and work-based learning (WBL) providers by April 2003. PROBE has assisted 3000 organizations across…

  7. Cultivating Excellence: A Curriculum for Excellence in School Administration. V. School-Based Management.

    ERIC Educational Resources Information Center

    Lawson, John

    This report is the fifth in a series on cultivating excellence in education for the purpose of training and retraining school leaders of the 1990s. The role of school administrators, and especially building principals; the characteristic administrative functions; the step-by-step procedures for implementation; and the advantages and possible…

  8. Evaluation of backside particle contamination and electrostatic chuck design on the cleanliness of EUV reticle mask blanks in a multilayer Mo/Si ion beam deposition system

    NASA Astrophysics Data System (ADS)

    Hayes, A. V.; Randive, R.; Reiss, I.; Menendez, J.; Kearney, P.; Sugiyama, T.

    2008-10-01

    A key requirement for the success of EUV lithography is a high volume supply of defect-free Mo/Si multilayer (ML)- coated mask blanks. The process of fabricating mask blanks is particularly sensitive to particle contamination because decoration by the deposition of the reflective stack on sub-lithographic (< 22 nm) particles can create larger, printable defects. One possible source of added defects is the mask substrate fixturing method, which, in the Veeco ion beam deposition (IBD) system used to deposit our ML coatings, must allow tilt and rotation of a vertically oriented substrate. As commonly practiced, an electrostatic chuck (ESC) is used instead of a mechanical clamping fixture to avoid transferring particles to the front surface of the mask by mechanical clamping and declamping operations. However, a large number of particles can be introduced to the backside of the mask by electrostatic clamping. Up to now, there has been little concern about such backside particles, except for relatively large particles (> 1 micron) that may affect out-of-plane distortion of the mask in an EUV lithography tool. As the cleanliness of the EUV masks and mask blank fabrication approaches perfection, however, there is more concern that particles transferred from the backside to the frontside of the mask may be a significant issue. Such transfer may occur in the deposition chamber, in the substrate cassette, or in the transfer module and may be indirect. In this paper, we present data from characterizing the amount, size, shape, composition, and location of the backside particle defects generated by electrostatic clamping, using a particle counter and scanning electron microscope (SEM), and compare results for a pin-type e-chuck, which has a small contact area, with the standard flat e-chuck. The key result is a 10X to 30X reduction in the total number of backside particles for the pin chuck. Also, preliminary data indicates that the pin chuck stays cleaner under service

  9. Center of excellence for small robots

    NASA Astrophysics Data System (ADS)

    Nguyen, Hoa G.; Carroll, Daniel M.; Laird, Robin T.; Everett, H. R.

    2005-05-01

    The mission of the Unmanned Systems Branch of SPAWAR Systems Center, San Diego (SSC San Diego) is to provide network-integrated robotic solutions for Command, Control, Communications, Computers, Intelligence, Surveillance, and Reconnaissance (C4ISR) applications, serving and partnering with industry, academia, and other government agencies. We believe the most important criterion for a successful acquisition program is producing a value-added end product that the warfighter needs, uses and appreciates. Through our accomplishments in the laboratory and field, SSC San Diego has been designated the Center of Excellence for Small Robots by the Office of the Secretary of Defense Joint Robotics Program. This paper covers the background, experience, and collaboration efforts by SSC San Diego to serve as the "Impedance-Matching Transformer" between the robotic user and technical communities. Special attention is given to our Unmanned Systems Technology Imperatives for Research, Development, Testing and Evaluation (RDT&E) of Small Robots. Active projects, past efforts, and architectures are provided as success stories for the Unmanned Systems Development Approach.

  10. Mini-implants and miniplates generate sub-absolute and absolute anchorage

    PubMed Central

    Consolaro, Alberto

    2014-01-01

    The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and resorption that happen to meet the functional demands. The endosteum and the periosteum are the effectors responsible for stimulating adaptive osteocytes in the inner and outer surfaces.Changes in shape, volume and position of the jaws as a result of skeletal correction of the maxilla and mandible require anchorage to allow bone remodeling to redefine morphology, esthetics and function as a result of spatial deformation conducted by orthodontic appliances. Examining the degree of changes in shape, volume and structural relationship of areas where mini-implants and miniplates are placed allows us to classify mini-implants as devices of subabsolute anchorage and miniplates as devices of absolute anchorage. PMID:25162561

  11. Absolute brightness temperature measurements at 2.1-mm wavelength

    NASA Technical Reports Server (NTRS)

    Ulich, B. L.

    1974-01-01

    Absolute measurements of the brightness temperatures of the Sun, new Moon, Venus, Mars, Jupiter, Saturn, and Uranus, and of the flux density of DR21 at 2.1-mm wavelength are reported. Relative measurements at 3.5-mm wavelength are also preented which resolve the absolute calibration discrepancy between The University of Texas 16-ft radio telescope and the Aerospace Corporation 15-ft antenna. The use of the bright planets and DR21 as absolute calibration sources at millimeter wavelengths is discussed in the light of recent observations.

  12. Absolute Antenna Calibration at the US National Geodetic Survey

    NASA Astrophysics Data System (ADS)

    Mader, G. L.; Bilich, A. L.

    2012-12-01

    Geodetic GNSS applications routinely demand millimeter precision and extremely high levels of accuracy. To achieve these accuracies, measurement and instrument biases at the centimeter to millimeter level must be understood. One of these biases is the antenna phase center, the apparent point of signal reception for a GNSS antenna. It has been well established that phase center patterns differ between antenna models and manufacturers; additional research suggests that the addition of a radome or the choice of antenna mount can significantly alter those a priori phase center patterns. For the more demanding GNSS positioning applications and especially in cases of mixed-antenna networks, it is all the more important to know antenna phase center variations as a function of both elevation and azimuth in the antenna reference frame and incorporate these models into analysis software. Determination of antenna phase center behavior is known as "antenna calibration". Since 1994, NGS has computed relative antenna calibrations for more than 350 antennas. In recent years, the geodetic community has moved to absolute calibrations - the IGS adopted absolute antenna phase center calibrations in 2006 for use in their orbit and clock products, and NGS's CORS group began using absolute antenna calibration upon the release of the new CORS coordinates in IGS08 epoch 2005.00 and NAD 83(2011,MA11,PA11) epoch 2010.00. Although NGS relative calibrations can be and have been converted to absolute, it is considered best practice to independently measure phase center characteristics in an absolute sense. Consequently, NGS has developed and operates an absolute calibration system. These absolute antenna calibrations accommodate the demand for greater accuracy and for 2-dimensional (elevation and azimuth) parameterization. NGS will continue to provide calibration values via the NGS web site www.ngs.noaa.gov/ANTCAL, and will publish calibrations in the ANTEX format as well as the legacy ANTINFO

  13. Direct comparisons between absolute and relative geomagnetic paleointensities: Absolute calibration of a relative paleointensity stack

    NASA Astrophysics Data System (ADS)

    Mochizuki, N.; Yamamoto, Y.; Hatakeyama, T.; Shibuya, H.

    2013-12-01

    Absolute geomagnetic paleointensities (APIs) have been estimated from igneous rocks, while relative paleomagnetic intensities (RPIs) have been reported from sediment cores. These two datasets have been treated separately, as correlations between APIs and RPIs are difficult on account of age uncertainties. High-resolution RPI stacks have been constructed from globally distributed sediment cores with high sedimentation rates. Previous studies often assumed that the RPI stacks have a linear relationship with geomagnetic axial dipole moments, and calibrated the RPI values to API values. However, the assumption of a linear relationship between APIs and RPIs has not been evaluated. Also, a quantitative calibration method for the RPI is lacking. We present a procedure for directly comparing API and RPI stacks, thus allowing reliable calibrations of RPIs. Direct comparisons between APIs and RPIs were conducted with virtually no associated age errors using both tephrochronologic correlations and RPI minima. Using the stratigraphic positions of tephra layers in oxygen isotope stratigraphic records, we directly compared the RPIs and APIs reported from welded tuffs contemporaneously extruded with the tephra layers. In addition, RPI minima during geomagnetic reversals and excursions were compared with APIs corresponding to the reversals and excursions. The comparison of APIs and RPIs at these exact points allowed a reliable calibration of the RPI values. We applied this direct comparison procedure to the global RPI stack PISO-1500. For six independent calibration points, virtual axial dipole moments (VADMs) from the corresponding APIs and RPIs of the PISO-1500 stack showed a near-linear relationship. On the basis of the linear relationship, RPIs of the stack were successfully calibrated to the VADMs. The direct comparison procedure provides an absolute calibration method that will contribute to the recovery of temporal variations and distributions of geomagnetic axial dipole

  14. Developing the excellence habit: 25 rules to live by.

    PubMed

    Hills, Laura

    2011-01-01

    Most medical practice employees agree pretty readily that they want to achieve a high level of excellence both in their work and in their lives. But defining and achieving excellence can be a challenge. This article explores specifically what it means to be excellent both inside and outside the medical practice. It suggests that the small things we do and the company we keep definitely matter and that excellence can become habitual if it is repeated again and again. Specifically, this article provides 25 clearly defined rules medical practice employees can learn and live by to develop and increase their personal excellence. It describes three hallmarks common to all excellent medical practice employees and five benefits of excellence. Finally, this article provides 10 daily affirmations the medical practice employee can use to develop and cement his or her own habit of excellence. PMID:21595386

  15. Microsoft Excel as a Supplement to Intermediate Algebra

    ERIC Educational Resources Information Center

    Stephens, Larry J.

    2003-01-01

    Excel assignments were used as extra credit in an intermediate algebra course. Ninety percent of the students had a home computer and seventy per cent were familiar with Excel. There was not a significant linear correlation between the amount of Excel that the students performed and their achievement in algebra. One-third of the students did less…

  16. Urban Schools: Community Leadership, Excellence in Teaching, Systemic Change.

    ERIC Educational Resources Information Center

    Poliakoff, Anne Rogers, Ed.

    2001-01-01

    This collection of essays discusses excellence and achievement in urban schools. "Needed: Excellent Teachers for Urban Schools" (Diane Ravitch) suggests that the best thing to do to help urban students is to ensure that they have excellent teachers. "Beyond the Courage to Change Urban School Systems" (Rudolph F. Crew) discusses how much difference…

  17. Christian Schooling and Educational Excellence: An Australian Perspective

    ERIC Educational Resources Information Center

    Justins, Charles

    2009-01-01

    This paper considers from an Australian perspective the tensions for Christian schooling in the notion of educational excellence and whether, ultimately, it is possible for a Christian school to promote itself as a centre for educational excellence and remain authentically Christian. The language of excellence is prevalent in Western society, and…

  18. ExceL through Innovation. Evaluation Report, 1998-99.

    ERIC Educational Resources Information Center

    Koehler, Holly

    ExceL through Innovation (ExceL) is a local funding initiative of the Austin Independent School District (AISD), Texas, created to enhance elementary student achievement through innovative programs designed at the campus level for the specific students served. By 1998, 68 campuses were receiving ExceL funds. In spring 1998, principals of the ExceL…

  19. Overcoming Microsoft Excel's Weaknesses for Crop Model Building and Simulations

    ERIC Educational Resources Information Center

    Sung, Christopher Teh Boon

    2011-01-01

    Using spreadsheets such as Microsoft Excel for building crop models and running simulations can be beneficial. Excel is easy to use, powerful, and versatile, and it requires the least proficiency in computer programming compared to other programming platforms. Excel, however, has several weaknesses: it does not directly support loops for iterative…

  20. Searching for Excellence in Education: Knowledge, Virtue and Presence?

    ERIC Educational Resources Information Center

    MacAllister, James; Macleod, Gale; Pirrie, Anne

    2013-01-01

    This article addresses two main questions: (1) what is excellence and (2) should epistemic excellence be the main purpose of education? Though references to excellence have become increasingly frequent in the UK education policy, these questions are perhaps especially important in Scotland where the curriculum is explicitly "for"…

  1. Enhancing Teaching using MATLAB Add-Ins for Excel

    ERIC Educational Resources Information Center

    Hamilton, Paul V.

    2004-01-01

    In this paper I will illustrate how to extend the capabilities of Microsoft Excel spreadsheets with add-ins created by MATLAB. Excel provides a broad array of fundamental tools but often comes up short when more sophisticated scenarios are involved. To overcome this short-coming of Excel while retaining its ease of use, I will describe how…

  2. 75 FR 4822 - 2010 Travel and Relocation Excellence Award

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-29

    ... ADMINISTRATION 2010 Travel and Relocation Excellence Award AGENCY: Office of Governmentwide Policy, General... seeking candidates for the biennial 2010 Travel and Relocation Excellence Award, which honors excellence in federal travel and relocation policy. FOR FURTHER INFORMATION CONTACT: Go to GSA's 2010 Travel...

  3. In Search of Excellence: Historical Roots of Greek Culture.

    ERIC Educational Resources Information Center

    Makedon, Alexander

    This paper seeks to discover conditions that motivate people to achieve excellence and uses the Greek culture as an example of excellence. The document addresses the basic questions: (1) What were the social conditions that resulted in what is widely known as the "Greek Miracle"?; (2) What motivated the ancient Greeks to excel, especially their…

  4. Excellence: The Importance of Vision and Work Ethic

    ERIC Educational Resources Information Center

    Hill, Roger B.

    2010-01-01

    In this paper, the author discusses the topic of excellence and shares key aspects of excellence that he has found to be true in his life's journey. He discusses two elements of excellence, namely (1) "vision"; and (2) "work ethic", and describes some characteristics of each element. Three aspects: (1) interpersonal skills; (2) initiative; and (3)…

  5. Absolute calibration of sniffer probes on Wendelstein 7-X.

    PubMed

    Moseev, D; Laqua, H P; Marsen, S; Stange, T; Braune, H; Erckmann, V; Gellert, F; Oosterbeek, J W

    2016-08-01

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m(2) per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m(2) per MW injected beam power is measured. PMID:27587121

  6. Absolute Value Boundedness, Operator Decomposition, and Stochastic Media and Equations

    NASA Technical Reports Server (NTRS)

    Adomian, G.; Miao, C. C.

    1973-01-01

    The research accomplished during this period is reported. Published abstracts and technical reports are listed. Articles presented include: boundedness of absolute values of generalized Fourier coefficients, propagation in stochastic media, and stationary conditions for stochastic differential equations.

  7. The conditions of absolute summability of multiple trigonometric series

    NASA Astrophysics Data System (ADS)

    Bitimkhan, Samat; Akishev, Gabdolla

    2015-09-01

    In this work necessary and sufficient conditions of absolute summability of multiple trigonometric Fourier series of functions from anisotropic spaces of Lebesque are found in terms of its best approximation, the module of smoothness and the mixed smoothness module.

  8. Absolute calibration of sniffer probes on Wendelstein 7-X

    NASA Astrophysics Data System (ADS)

    Moseev, D.; Laqua, H. P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V.; Gellert, F.; Oosterbeek, J. W.

    2016-08-01

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m2 per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m2 per MW injected beam power is measured.

  9. Absolute and Convective Instability of a Liquid Jet in Microgravity

    NASA Technical Reports Server (NTRS)

    Lin, Sung P.; Vihinen, I.; Honohan, A.; Hudman, Michael D.

    1996-01-01

    The transition from convective to absolute instability is observed in the 2.2 second drop tower of the NASA Lewis Research Center. In convective instability the disturbance grows spatially as it is convected downstream. In absolute instability the disturbance propagates both downstream and upstream, and manifests itself as an expanding sphere. The transition Reynolds numbers are determined for two different Weber numbers by use of Glycerin and a Silicone oil. Preliminary comparisons with theory are made.

  10. Absolute biphoton meter of the quantum efficiency of photomultipliers

    NASA Astrophysics Data System (ADS)

    Ginzburg, V. M.; Keratishvili, N. G.; Korzhenevich, E. L.; Lunev, G. V.; Sapritskii, V. I.

    1992-07-01

    An biphoton absolute meter of photomultiplier quantum efficiency is presented which is based on spontaneous parametric down-conversion. Calculation and experiment results were obtained which made it possible to choose the parameters of the setup that guarantee a linear dependence of wavelength on the Z coordinate (along the axicon axis). Results of a series of absolute measurements of the quantum efficiency of a specific photomultiplier (FEU-136) are presented.

  11. Absolute/convective instability of planar viscoelastic jets

    NASA Astrophysics Data System (ADS)

    Ray, Prasun K.; Zaki, Tamer A.

    2015-01-01

    Spatiotemporal linear stability analysis is used to investigate the onset of local absolute instability in planar viscoelastic jets. The influence of viscoelasticity in dilute polymer solutions is modeled with the FENE-P constitutive equation which requires the specification of a non-dimensional polymer relaxation time (the Weissenberg number, We), the maximum polymer extensibility, L, and the ratio of solvent and solution viscosities, β. A two-parameter family of velocity profiles is used as the base state with the parameter, S, controlling the amount of co- or counter-flow while N-1 sets the thickness of the jet shear layer. We examine how the variation of these fluid and flow parameters affects the minimum value of S at which the flow becomes locally absolutely unstable. Initially setting the Reynolds number to Re = 500, we find that the first varicose jet-column mode dictates the presence of absolute instability, and increasing the Weissenberg number produces important changes in the nature of the instability. The region of absolute instability shifts towards thin shear layers, and the amount of back-flow needed for absolute instability decreases (i.e., the influence of viscoelasticity is destabilizing). Additionally, when We is sufficiently large and N-1 is sufficiently small, single-stream jets become absolutely unstable. Numerical experiments with approximate equations show that both the polymer and solvent contributions to the stress become destabilizing when the scaled shear rate, η = /W e dU¯1/dx 2L ( /d U ¯ 1 d x 2 is the base-state velocity gradient), is sufficiently large. These qualitative trends are largely unchanged when the Reynolds number is reduced; however, the relative importance of the destabilizing stresses increases tangibly. Consequently, absolute instability is substantially enhanced, and single-stream jets become absolutely unstable over a sizable portion of the parameter space.

  12. Heat capacity and absolute entropy of iron phosphides

    SciTech Connect

    Dobrokhotova, Z.V.; Zaitsev, A.I.; Litvina, A.D.

    1994-09-01

    There is little or no data on the thermodynamic properties of iron phosphides despite their importance for several areas of science and technology. The information available is of a qualitative character and is based on assessments of the heat capacity and absolute entropy. In the present work, we measured the heat capacity over the temperature range of 113-873 K using a differential scanning calorimeter (DSC) and calculated the absolute entropy.

  13. Global absolut gravity reference system as replacement of IGSN 71

    NASA Astrophysics Data System (ADS)

    Wilmes, Herbert; Wziontek, Hartmut; Falk, Reinhard

    2015-04-01

    The determination of precise gravity field parameters is of great importance in a period in which earth sciences are achieving the necessary accuracy to monitor and document global change processes. This is the reason why experts from geodesy and metrology joined in a successful cooperation to make absolute gravity observations traceable to SI quantities, to improve the metrological kilogram definition and to monitor mass movements and smallest height changes for geodetic and geophysical applications. The international gravity datum is still defined by the International Gravity Standardization Net adopted in 1971 (IGSN 71). The network is based upon pendulum and spring gravimeter observations taken in the 1950s and 60s supported by the early free fall absolute gravimeters. Its gravity values agreed in every case to better than 0.1 mGal. Today, more than 100 absolute gravimeters are in use worldwide. The series of repeated international comparisons confirms the traceability of absolute gravity measurements to SI quantities and confirm the degree of equivalence of the gravimeters in the order of a few µGal. For applications in geosciences where e.g. gravity changes over time need to be analyzed, the temporal stability of an absolute gravimeter is most important. Therefore, the proposition is made to replace the IGSN 71 by an up-to-date gravity reference system which is based upon repeated absolute gravimeter comparisons and a global network of well controlled gravity reference stations.

  14. Revisiting absolute and relative judgments in the WITNESS model.

    PubMed

    Fife, Dustin; Perry, Colton; Gronlund, Scott D

    2014-04-01

    The WITNESS model (Clark in Applied Cognitive Psychology 17:629-654, 2003) provides a theoretical framework with which to investigate the factors that contribute to eyewitness identification decisions. One key factor involves the contributions of absolute versus relative judgments. An absolute contribution is determined by the degree of match between an individual lineup member and memory for the perpetrator; a relative contribution involves the degree to which the best-matching lineup member is a better match to memory than the remaining lineup members. In WITNESS, the proportional contributions of relative versus absolute judgments are governed by the values of the decision weight parameters. We conducted an exploration of the WITNESS model's parameter space to determine the identifiability of these relative/absolute decision weight parameters, and compared the results to a restricted version of the model that does not vary the decision weight parameters. This exploration revealed that the decision weights in WITNESS are difficult to identify: Data often can be fit equally well by setting the decision weights to nearly any value and compensating with a criterion adjustment. Clark, Erickson, and Breneman (Law and Human Behavior 35:364-380, 2011) claimed to demonstrate a theoretical basis for the superiority of lineup decisions that are based on absolute contributions, but the relationship between the decision weights and the criterion weakens this claim. These findings necessitate reconsidering the role of the relative/absolute judgment distinction in eyewitness decision making. PMID:23943556

  15. Academic excellence workshops in chemistry and physics

    NASA Astrophysics Data System (ADS)

    Mills, Susan Rose

    In the mid-1970's, Uri Treisman, at the University of California, Berkeley, developed an academic excellence workshop program that had important successes in increasing minority student achievement and persistence in calculus. The present dissertation research is an in-depth study of chemistry and physics workshops at the California State Polytechnic University, Pomona. Data for the first, longitudinal component of this study were obtained by tracking to Spring 1998 all workshop minority students, i.e., Latino, African American, and Native American workshop students, a random sample of non-workshop minority students, and a random sample of non-targeted students, i.e., Anglo and Asian students, enrolled in first-quarter General Chemistry or Physics during specific quarters of 1992 or 1993. Data for the second component were obtained by administering questionnaires, conducting interviews, and observing science students during Fall, 1996. Workshop participation was a significant predictor of first-quarter course grade for minority students in both chemistry and physics, while verbal and mathematics Scholastic Aptitude Test (SAT) scores were not significant predictors of beginning course grade for minority science students. The lack of predictive ability of the SAT and the importance of workshop participation in minority students' beginning science course performance are results with important implications for educators and students. In comparing pre-college achievement measures for workshop and non-targeted students, non-targeted students' mathematics SAT scores were significantly higher than chemistry and physics workshop students' scores. Nonetheless, workshop participation "leveled the field" as workshop and non-targeted students performed similarly in beginning science courses. Positive impacts of workshop participation on achievement, persistence, efficiency, social integration, and self-confidence support the continued and expanded funding of workshop programs

  16. Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF.

    PubMed

    Casey, D T; Frenje, J A; Gatu Johnson, M; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Knauer, J P; Meyerhofer, D D; Sangster, T C; Bionta, R M; Bleuel, D L; Döppner, T; Glenzer, S; Hartouni, E; Hatchett, S P; Le Pape, S; Ma, T; MacKinnon, A; McKernan, M A; Moran, M; Moses, E; Park, H-S; Ralph, J; Remington, B A; Smalyuk, V; Yeamans, C B; Kline, J; Kyrala, G; Chandler, G A; Leeper, R J; Ruiz, C L; Cooper, G W; Nelson, A J; Fletcher, K; Kilkenny, J; Farrell, M; Jasion, D; Paguio, R

    2012-10-01

    A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF. PMID:23126915

  17. Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF

    SciTech Connect

    Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Seguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Knauer, J. P.; Meyerhofer, D. D.; Sangster, T. C.; Bionta, R. M.; Bleuel, D. L.; Doeppner, T.; Glenzer, S.; Hartouni, E.; Hatchett, S. P.; Le Pape, S.; Ma, T.; MacKinnon, A.; and others

    2012-10-15

    A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  18. Helical, Axial, and Central Chirality Combined in a Single Cage: Synthesis, Absolute Configuration, and Recognition Properties.

    PubMed

    Zhang, Dawei; Mulatier, Jean-Christophe; Cochrane, James Robert; Guy, Laure; Gao, Guohua; Dutasta, Jean-Pierre; Martinez, Alexandre

    2016-06-01

    The synthesis of eight enantiopure molecular cages (four diastereomeric pairs of enantiomers) comprising a helically chiral cyclotriveratrylene (CTV) unit, three axially chiral binaphthol linkages, and three centrally asymmetric carbon atoms of a trialkanolamine core, is described. These new cages constitute a novel family of hemicryptophanes, which combine three classes of chirality. Their absolute configuration was successfully assigned by a chemical correlation method to overcome the signals overlap in the ECD spectra of the binaphtol and CTV units. Stereoselective recognition of glucose and mannose derivatives was investigated with these new chiral cages. Excellent enantio- and diastereoselectivity were reached, since in some cases, both exclusive enantio- and diastereo-discrimination have been observed. In addition, compared with the most relevant hemicryptophanes, these new cages also exhibit improved binding affinities. PMID:27037555

  19. A Helium-Cooled Absolute Cavity Radiometer For Solar And Laboratory Irradiance Measurement

    NASA Astrophysics Data System (ADS)

    Foukal, P.; Miller, P.

    1983-09-01

    We describe the design and testing of a helium-cooled absolute radiometer (HCAR) devel-oped for highly reproducible measurements of total solar irradiance and ultraviolet flux, and for laboratory standards uses. The receiver of this cryogenic radiometer is a blackened cone of pure copper whose temperature is sensed by a germanium resistance thermometer. During a duty cycle, radiant power input is compared to electrical heating in an accurate resistor wound on the receiver, as in conventional self-calibrating radiometers of the PACRAD and ACR type. But operation at helium temperatures enables us to achieve excellent radia-tive shielding between the receiver and the radiometer thermal background. This enables us to attain a sensitivity level of 10-7 watts at 30 seconds integration time, at least 10 times better than achieved by room temperature cavities. The dramatic drop of copper specific heat at helium temperatures reduces the time constant for a given mass of receiver, by a factor of 103. Together with other cryogenic materials properties such as electrical superconductivity and the high thermal conductivity of copper, this can be used to greatly reduce non-equivalence errors between electrical and radiant heating, that presently limit the absolute accuracy of radiometers to approximately 0,2%. Absolute accuracy of better than 0.01% has been achieved with a similar cryogenic radiometer in laboratory measurements of the Stefan-Boltzmann constant at NPL in the U.K. Electrical and radiometric tests con-ducted so far on our prototype indicate that comparable accuracy and long-term reproducibility can be achieved in a versatile instrument of manageable size for Shuttle flight and laboratory standards uses. This work is supported at AER under NOAA contract NA8ORAC00204 and NSF grant DMR-8260273.

  20. Sulfur-based absolute quantification of proteins using isotope dilution inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Lee, Hyun-Seok; Heun Kim, Sook; Jeong, Ji-Seon; Lee, Yong-Moon; Yim, Yong-Hyeon

    2015-10-01

    An element-based reductive approach provides an effective means of realizing International System of Units (SI) traceability for high-purity biological standards. Here, we develop an absolute protein quantification method using double isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) combined with microwave-assisted acid digestion for the first time. We validated the method and applied it to certify the candidate protein certified reference material (CRM) of human growth hormone (hGH). The concentration of hGH was determined by analysing the total amount of sulfur in hGH. Next, the size-exclusion chromatography method was used with ICP-MS to characterize and quantify sulfur-containing impurities. By subtracting the contribution of sulfur-containing impurities from the total sulfur content in the hGH CRM, we obtained a SI-traceable certification value. The quantification result obtained with the present method based on sulfur analysis was in excellent agreement with the result determined via a well-established protein quantification method based on amino acid analysis using conventional acid hydrolysis combined with an ID liquid chromatography-tandem mass spectrometry. The element-based protein quantification method developed here can be generally used for SI-traceable absolute quantification of proteins, especially pure-protein standards.

  1. Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fields

    PubMed Central

    Paganetti, Harald

    2008-01-01

    The prescribed dose in radiation therapy has to be converted into machine monitor units for patient treatment. This is done routinely for each spread-out Bragg peak (SOBP) field either by calibration measurements, by using analytical algorithms or by relying on empirical data. At the Northeast Proton Therapy Center, a monitor unit corresponds to a fixed amount of charge collected in a segmented transmission ionization chamber inside the treatment head. The goal of this work was to use a detailed Monte Carlo model of the treatment head to calculate the dose delivered to the patient as a function of ionization chamber reading, i.e. to yield absolute dose in patients in terms of machine monitor units. The results show excellent agreement with measurements. For 50 SOBP fields considered in this study, the mean absolute difference between the experimental and the calculated value is 1.5%, where ~50% of the fields agree within 1%. This is within the uncertainties of the data. The Monte Carlo method has advantages over analytical algorithms because it takes into account scattered and secondary radiation, does not rely on empirical parameters, and provides a tool to study the influence of parts of the treatment head on the ionization chamber reading. Compared to experimental methods the Monte Carlo method has the advantage of being able to verify the dose in the patient geometry. PMID:16723767

  2. Absolute irradiance of the Moon for on-orbit calibration

    USGS Publications Warehouse

    Stone, T.C.; Kieffer, H.H.

    2002-01-01

    The recognized need for on-orbit calibration of remote sensing imaging instruments drives the ROLO project effort to characterize the Moon for use as an absolute radiance source. For over 5 years the ground-based ROLO telescopes have acquired spatially-resolved lunar images in 23 VNIR (Moon diameter ???500 pixels) and 9 SWIR (???250 pixels) passbands at phase angles within ??90 degrees. A numerical model for lunar irradiance has been developed which fits hundreds of ROLO images in each band, corrected for atmospheric extinction and calibrated to absolute radiance, then integrated to irradiance. The band-coupled extinction algorithm uses absorption spectra of several gases and aerosols derived from MODTRAN to fit time-dependent component abundances to nightly observations of standard stars. The absolute radiance scale is based upon independent telescopic measurements of the star Vega. The fitting process yields uncertainties in lunar relative irradiance over small ranges of phase angle and the full range of lunar libration well under 0.5%. A larger source of uncertainty enters in the absolute solar spectral irradiance, especially in the SWIR, where solar models disagree by up to 6%. Results of ROLO model direct comparisons to spacecraft observations demonstrate the ability of the technique to track sensor responsivity drifts to sub-percent precision. Intercomparisons among instruments provide key insights into both calibration issues and the absolute scale for lunar irradiance.

  3. Absolute luminosity measurements with the LHCb detector at the LHC

    NASA Astrophysics Data System (ADS)

    LHCb Collaboration

    2012-01-01

    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic ``van der Meer scan'' method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overal precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.

  4. PREMOS Absolute Radiometer Calibration and Implications to on-orbit Measurements of the Total Solar Irradiance

    NASA Astrophysics Data System (ADS)

    Fehlmann, A.; Kopp, G.; Schmutz, W. K.; Winkler, R.; Finsterle, W.; Fox, N.

    2011-12-01

    On orbit measurements starting in the late 1970's, have revealed the 11 year cycle of the Total Solar Irradiance (TSI). However, the absolute results from individual experiments differ although all instrument teams claim to measure an absolute value. Especially the data from the TIM/SORCE experiment confused the community as it measures 0.3 % lower than the other instruments, e.g. VIRGO/SOHO by PMOD/WRC, which clearly exceeds the uncertainty stated for the absolute characterization of the experiments. The PREMOS package on the PICARD platform launched in June 2010 is the latest space experiment by PMOD/WRC measuring the TSI. We have put great effort in the calibration and characterization of this instrument in order to resolve the inter-instrument differences. We performed calibrations at the National Physical Laboratory (NPL) in London and the Laboratory for Atmospheric and Space Physics (LASP) in Boulder against national SI standards for radiant power using a laser beam with a diameter being smaller than the aperture of the instrument. These measurements together with the World Radiometric Reference (WRR) calibration in Davos allowed to compare the WRR and the SI radiant power scale. We found that the WRR lies 0.18 % above the SI radiant power scale which explains a part of the VIRGO-TIM difference. The Total solar irradiance Radiometer Facility (TRF) at the LASP allows to generate a beam that over fills the apertures of our instruments, giving the presently best available representation of solar irradiance in a laboratory. These irradiance calibrations revealed a stray light contribution between 0.09 and 0.3 % to the measurements which had been underestimated in the characterization of our instruments. Using the irradiance calibrations, we found that the WRR lies 0.32 % above the TRF scale which in turn explains the full VIRGO-TIM difference. The first light PREMOS measurements in space confirmed our findings. If we use the WRR calibration, PREMOS yields a TSI

  5. System and method for calibrating a rotary absolute position sensor

    NASA Technical Reports Server (NTRS)

    Davis, Donald R. (Inventor); Permenter, Frank Noble (Inventor); Radford, Nicolaus A (Inventor)

    2012-01-01

    A system includes a rotary device, a rotary absolute position (RAP) sensor generating encoded pairs of voltage signals describing positional data of the rotary device, a host machine, and an algorithm. The algorithm calculates calibration parameters usable to determine an absolute position of the rotary device using the encoded pairs, and is adapted for linearly-mapping an ellipse defined by the encoded pairs to thereby calculate the calibration parameters. A method of calibrating the RAP sensor includes measuring the rotary position as encoded pairs of voltage signals, linearly-mapping an ellipse defined by the encoded pairs to thereby calculate the calibration parameters, and calculating an absolute position of the rotary device using the calibration parameters. The calibration parameters include a positive definite matrix (A) and a center point (q) of the ellipse. The voltage signals may include an encoded sine and cosine of a rotary angle of the rotary device.

  6. Method and apparatus for two-dimensional absolute optical encoding

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B. (Inventor)

    2004-01-01

    This invention presents a two-dimensional absolute optical encoder and a method for determining position of an object in accordance with information from the encoder. The encoder of the present invention comprises a scale having a pattern being predetermined to indicate an absolute location on the scale, means for illuminating the scale, means for forming an image of the pattern; and detector means for outputting signals derived from the portion of the image of the pattern which lies within a field of view of the detector means, the field of view defining an image reference coordinate system, and analyzing means, receiving the signals from the detector means, for determining the absolute location of the object. There are two types of scale patterns presented in this invention: grid type and starfield type.

  7. Absolute and Convective Instability in Fluid-Conveying Flexible Pipes

    NASA Astrophysics Data System (ADS)

    de Langre, E.; Ouvrard, A. E.

    1998-11-01

    The effect of internal plug flow on the lateral stability of fluid conveying flexible pipes is investigated by determining the absolute/convective nature of the instability from the analytically derived linear dispersion relation. The fluid-structure interaction is modeled following the work of Gregory and Paidoussis (1966). The different domains of stability, convective instability, and absolute instability are explicitly derived in parameter space. The effect of flow velocity, mass ratio between the fluid and the structure, stiffness of the elastic foundation and axial tension is considered. Absolute instability prevails over a wide range of parameters. Convective instability only takes place at very high mass ratio, small stiffness and small axial tension. Relation is made with previous work of Brazier-Smith & Scott (1984) and Crighton (1991), considered here as a short wave approximation.

  8. Absolute surface metrology by rotational averaging in oblique incidence interferometry.

    PubMed

    Lin, Weihao; He, Yumei; Song, Li; Luo, Hongxin; Wang, Jie

    2014-06-01

    A modified method for measuring the absolute figure of a large optical flat surface in synchrotron radiation by a small aperture interferometer is presented. The method consists of two procedures: the first step is oblique incidence measurement; the second is multiple rotating measurements. This simple method is described in terms of functions that are symmetric or antisymmetric with respect to reflections at the vertical axis. Absolute deviations of a large flat surface could be obtained when mirror antisymmetric errors are removed by N-position rotational averaging. Formulas are derived for measuring the absolute surface errors of a rectangle flat, and experiments on high-accuracy rectangle flats are performed to verify the method. Finally, uncertainty analysis is carried out in detail. PMID:24922410

  9. THE LINDA CRANE MEMORIAL LECTURE: Striving for Excellence

    PubMed Central

    Hayes, Sherrill H

    2010-01-01

    Historically, invited lecturers have often challenged us to define excel lence in physical therapy practice, or in our academic programs. While some have addressed different char acteristics of excellence, our profession has not really come together to address 2 very important questions: what does “quality” mean in physical therapist education? And how do we measure it? Using 3 elements of Friendship, Leadership, and Mentoring, and Defining Excellence and juxtaposing these with Linda Crane and her life, a vision of excellence in physical therapy educational programs was explored in this invited lecture. The text of that lecture ensues. PMID:20520760

  10. Non-Invasive Method of Determining Absolute Intracranial Pressure

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Cantrell, John H., Jr. (Inventor); Hargens, Alan E. (Inventor)

    2004-01-01

    A method is presented for determining absolute intracranial pressure (ICP) in a patient. Skull expansion is monitored while changes in ICP are induced. The patient's blood pressure is measured when skull expansion is approximately zero. The measured blood pressure is indicative of a reference ICP value. Subsequently, the method causes a known change in ICP and measured the change in skull expansion associated therewith. The absolute ICP is a function of the reference ICP value, the known change in ICP and its associated change in skull expansion; and a measured change in skull expansion.

  11. Measurements of the reactor neutron power in absolute units

    NASA Astrophysics Data System (ADS)

    Lebedev, G. V.

    2015-12-01

    The neutron power of the reactor of the Yenisei space nuclear power plant is measured in absolute units using the modernized method of correlation analysis during the ground-based tests of the Yenisei prototypes. Results of the experiments are given. The desired result is obtained in a series of experiments carried out at the stage of the plant preparation for tests. The acceptability of experimental data is confirmed by the results of measuring the reactor neutron power in absolute units at the nominal level by the thermal balance during the life cycle tests of the ground prototypes.

  12. In-flight absolute radiometric calibration of the thematic mapper

    NASA Technical Reports Server (NTRS)

    Castle, K. R.; Holm, R. G.; Kastner, C. J.; Palmer, J. M.; Slater, P. N.; Dinguirard, M.; Ezra, C. E.; Jackson, R. D.; Savage, R. K.

    1983-01-01

    The TM multispectral scanner system was calibrated in an absolute manner before launch. To determine the temporal changes of the absolute radiometric calibration of the entire system, spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM collections over White Sands, New Mexico. By entering the measured values in an atmospheric radiative transfer program, the radiance levels of the in four of the spectral bands of the TM were determined. Tables show values for the reflectance of snow at White Sands measured by a modular 8 channel radiometer, and values for exoatmospheric irradiance within the TM passbands, calculated for the Earth-Sun distance using a solar radiometer.

  13. Absolute photon-flux measurements in the vacuum ultraviolet

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.; Haddad, G. N.

    1974-01-01

    Absolute photon-flux measurements in the vacuum ultraviolet have extended to short wavelengths by use of rare-gas ionization chambers. The technique involves the measurement of the ion current as a function of the gas pressure in the ion chamber. The true value of the ion current, and hence the absolute photon flux, is obtained by extrapolating the ion current to zero gas pressure. Examples are given at 162 and 266 A. The short-wavelength limit is determined only by the sensitivity of the current-measuring apparatus and by present knowledge of the photoionization processes that occur in the rate gases.

  14. Notes on Van der Meer scan for absolute luminosity measurement

    NASA Astrophysics Data System (ADS)

    Balagura, Vladislav

    2011-10-01

    The absolute luminosity can be measured in an accelerator by sweeping beams transversely across each other in the so-called van der Meer scan. We prove that the method can be applied in the general case of arbitrary beam directions and a separation scan plane. A simple method to develop an image of the beam in its transverse plane from spatial distributions of interaction vertexes is also proposed. From the beam images one can determine their overlap and the absolute luminosity. This provides an alternative way of the luminosity measurement during van der Meer scan.

  15. Measurements of the reactor neutron power in absolute units

    SciTech Connect

    Lebedev, G. V.

    2015-12-15

    The neutron power of the reactor of the Yenisei space nuclear power plant is measured in absolute units using the modernized method of correlation analysis during the ground-based tests of the Yenisei prototypes. Results of the experiments are given. The desired result is obtained in a series of experiments carried out at the stage of the plant preparation for tests. The acceptability of experimental data is confirmed by the results of measuring the reactor neutron power in absolute units at the nominal level by the thermal balance during the life cycle tests of the ground prototypes.

  16. Absolute Stability Analysis of a Phase Plane Controlled Spacecraft

    NASA Technical Reports Server (NTRS)

    Jang, Jiann-Woei; Plummer, Michael; Bedrossian, Nazareth; Hall, Charles; Jackson, Mark; Spanos, Pol

    2010-01-01

    Many aerospace attitude control systems utilize phase plane control schemes that include nonlinear elements such as dead zone and ideal relay. To evaluate phase plane control robustness, stability margin prediction methods must be developed. Absolute stability is extended to predict stability margins and to define an abort condition. A constrained optimization approach is also used to design flex filters for roll control. The design goal is to optimize vehicle tracking performance while maintaining adequate stability margins. Absolute stability is shown to provide satisfactory stability constraints for the optimization.

  17. A general relativistic model for free-fall absolute gravimeters

    NASA Astrophysics Data System (ADS)

    Tan, Yu-Jie; Shao, Cheng-Gang; Li, Jia; Hu, Zhong-Kun

    2016-04-01

    Although the relativistic manifestations of gravitational fields in gravimetry were first studied 40 years ago, the relativistic effects combined with free-fall absolute gravimeters have rarely been considered. In light of this, we present a general relativistic model for free-fall absolute gravimeters in a local-Fermi coordinates system, where we focus on effects related to the measuring devices: relativistic transverse Doppler effects, gravitational redshift effects and Earth’s rotation effects. Based on this model, a general relativistic expression of the measured gravity acceleration is obtained.

  18. Absolute determination of inelastic mean-free paths and surface excitation parameters by absolute reflection electron energy loss spectrum analysis

    NASA Astrophysics Data System (ADS)

    Nagatomi, T.; Goto, K.

    2005-11-01

    An analytical approach was proposed for simultaneously determining an inelastic mean-free path (IMFP) and a surface excitation parameter (SEP) with absolute units by the analysis of an absolute experimental reflection electron energy loss spectrum. The IMFPs and SEPs in Ni were deduced for electrons of 300 to 3000 eV. The obtained IMFPs were in good agreement with those calculated using the TPP-2M equation. The Chen-type empirical formula was proposed for determining the SEP. The results confirmed the applicability of the present approach for determining the IMFP and SEP for medium-energy electrons.

  19. Mapping Excellence in National Research Systems: The Case of Italy

    ERIC Educational Resources Information Center

    Abramo, Giovanni; D'Angelo, Ciriaco Andrea; Di Costa, Flavia

    2009-01-01

    The study of "scientific excellence" is taking on increasing importance in the development of research policies in many nations. However, scientific excellence is difficult to define because of its multidimensional and highly complex character. This work contributes to the state of the art by exploring an effective, simple, and inexpensive…

  20. Microsoft Excel Software Usage for Teaching Science and Engineering Curriculum

    ERIC Educational Resources Information Center

    Singh, Gurmukh; Siddiqui, Khalid

    2009-01-01

    In this article, our main objective is to present the use of Microsoft Software Excel 2007/2003 for teaching college and university level curriculum in science and engineering. In particular, we discuss two interesting and fascinating examples of interactive applications of Microsoft Excel targeted for undergraduate students in: 1) computational…

  1. The German Excellence Initiative: Update. Go8 Backgrounder 24a

    ERIC Educational Resources Information Center

    Frohlich, Ellen

    2012-01-01

    As described in "Go8 Backgrounder 24: Answering the Global Challenge--Experiences from European Excellence Initiatives," Germany began a debate about how to strengthen its position as an excellent location for science and research in 2004. This debate focussed in particular on the competitiveness of the country's universities and research centres…

  2. Excellence and Enjoyment: The Logic of a "Contradiction"

    ERIC Educational Resources Information Center

    Hartley, David

    2006-01-01

    In 2004, the Department for Education and Skills in England published its Five Year Strategy for Children and Learners (DfES, 2004). It was preceded by Excellence and Enjoyment: a strategy for primary schools (DfES, 003). "Excellence and enjoyment" seems to constitute an ambiguity, even a contradiction. The government's view is otherwise. It…

  3. Excellence and Enjoyment: The Logic of a "Contradiction"

    ERIC Educational Resources Information Center

    Hartley, David

    2006-01-01

    In 2004, the Department for Education and Skills in England published its Five Year Strategy for Children and Learners (DfES, 2004). It was preceded by Excellence and Enjoyment: a strategy for primary schools (DfES, 2003). "Excellence and enjoyment" seems to constitute an ambiguity, even a contradiction. The government's view is otherwise. It…

  4. Linking the Faculty Recognition Process to Teaching Excellence.

    ERIC Educational Resources Information Center

    Shirk, Joseph; Miller, Marie

    Recently, there has been a growing emphasis on excellence in teaching and research in academia. Evaluative activities used in decisions related to retention, tenure, promotion, and merit salary increases can be positively linked to renewing faculty excellence in teaching. The development or revision of a faculty recognition document should allow…

  5. Finding Aristotle's Golden Mean: Social Justice and Academic Excellence

    ERIC Educational Resources Information Center

    Rivera, John

    2005-01-01

    Over 2,000 years ago, Aristotle wrote a treatise on ethics in which he proposed that there were both intellectual and moral virtues to be developed in the human being. Virtue ("aristeia") was roughly equivalent to the English word "excellence" and the unifying virtue that was both a moral and an intellectual virtue was prudence. Excellence lay not…

  6. The Oldest Cave Art: An Essay on Giftedness and Excellence.

    ERIC Educational Resources Information Center

    Breen, Maureen; White, David A.

    1996-01-01

    This essay examines issues of giftedness and excellence, beginning with classical references to human striving toward the "good," the attraction of gifted children to quality, and the recent discovery of the oldest known cave art with its manifest excellence. Classroom activities related to cave art and language arts, social studies, sciences,…

  7. Recognizing a Centre of Excellence in Ontario's Colleges

    ERIC Educational Resources Information Center

    Litwin, Jeffrey M.

    2012-01-01

    The term "Centre of Excellence" is increasingly used by Ontario's colleges with the expectation of portraying a superior level of proficiency, expertise, or investment in a particular academic discipline or program cluster. This paper proposes that the term Centre of Excellence should have a clearer definition so that when one of Ontario's…

  8. What Is Community College Excellence? Lessons from the Aspen Prize

    ERIC Educational Resources Information Center

    Wyner, Joshua

    2012-01-01

    Over the past year, in a process to select the winner of the Aspen Prize for Community College Excellence, the Aspen Institute has convened national experts to define and determine how to measure "excellence," to identify community colleges with high levels of student success, and to help more community colleges understand what can be done to…

  9. Exploring the Characteristics of "Teachers for Excellence": Teachers' Own Perceptions

    ERIC Educational Resources Information Center

    Grieve, Ann MacDonald

    2010-01-01

    This article is concerned first with identifying teacher characteristics connected with excellence. It then analyses the results of a survey conducted among primary school teachers in one local authority area in Scotland. Teachers responded to a questionnaire which asked them to rate in importance 44 characteristics of excellence. The findings…

  10. 77 FR 15089 - Equity and Excellence Commission Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-14

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF EDUCATION Equity and Excellence Commission Meeting AGENCY: Office for Civil Rights, U.S. Department of Education... up-coming meeting of the Equity and ] Excellence Commission (Commission). The notice also...

  11. 77 FR 33203 - Equity and Excellence Commission, Meeting Cancellation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-05

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF EDUCATION Equity and Excellence Commission, Meeting Cancellation AGENCY: U.S. Department of Education. ACTION..., Equity and Excellence Commission, U.S. Department of Education, 400 Maryland Avenue SW., Washington,...

  12. Technology Tips: Two Useful Functions for Excel Grade Books

    ERIC Educational Resources Information Center

    Lobo, Glen E.

    2006-01-01

    The topic of this month's department is writing macros in Excel. The examples given are of use to teachers who maintain their grade books in Excel, and show, for example, how to drop the lowest or choose the highest scores from a student's record. The Surfing Note cites a collection of online tools and resources for professional development…

  13. Promoting Excellent Teaching: The Chair as Academic Leader.

    ERIC Educational Resources Information Center

    Lamb, Bill

    Community college department chairs have many diverse responsibilities. One role which needs to be given more emphasis is that of "promoting excellent teaching." The three conditions which must be present for a department chair to begin promoting excellent teaching are open, honest, and positive communication; the ability to provide immediate…

  14. Improving the Pedagogy of Capital Structure Theory: An Excel Application

    ERIC Educational Resources Information Center

    Baltazar, Ramon; Maybee, Bryan; Santos, Michael R.

    2012-01-01

    This paper uses Excel to enhance the pedagogy of capital structure theory for corporate finance instructors and students. We provide a lesson plan that utilizes Excel spreadsheets and graphs to develop understanding of the theory. The theory is introduced in three scenarios that utilize Modigliani & Miller's Propositions and…

  15. Excel Spreadsheets for Algebra: Improving Mental Modeling for Problem Solving

    ERIC Educational Resources Information Center

    Engerman, Jason; Rusek, Matthew; Clariana, Roy

    2014-01-01

    This experiment investigates the effectiveness of Excel spreadsheets in a high school algebra class. Students in the experiment group convincingly outperformed the control group on a post lesson assessment. The student responses, teacher observations involving Excel spreadsheet revealed that it operated as a mindtool, which formed the users'…

  16. Automating Partial Period Bond Valuation with Excel's Day Counting Functions

    ERIC Educational Resources Information Center

    Vicknair, David; Spruell, James

    2009-01-01

    An Excel model for calculating the actual price of bonds under a 30 day/month, 360 day/year day counting assumption by nesting the DAYS360 function within the PV function is developed. When programmed into an Excel spreadsheet, the model can accommodate annual and semiannual payment bonds sold on or between interest dates using six fundamental…

  17. Excel in the Accounting Curriculum: Perceptions from Accounting Professors

    ERIC Educational Resources Information Center

    Ramachandran Rackliffe, Usha; Ragland, Linda

    2016-01-01

    Public accounting firms emphasize the importance of accounting graduates being proficient in Excel. Since many accounting graduates often aspire to work in public accounting, a question arises as to whether there should be an emphasis on Excel in accounting education. The purpose of this paper is to specifically look at this issue by examining…

  18. Leadership Characteristics of an Excellent Principal in Malaysia

    ERIC Educational Resources Information Center

    Fook, Chan Yuen; Sidhu, Gurnam Kaur

    2009-01-01

    Excellent principals are sense makers of schools that help create a sustainable school climate that will enhance students' and teachers' productivity. Hence they are not only the Chief Executive Officers (CEOs) but also the instructional leaders and motivators for their teams. In exploring the leadership characteristics of an excellent school…

  19. Series that Converge Absolutely but Don't Converge

    ERIC Educational Resources Information Center

    Kantrowitz, Robert; Schramm, Michael

    2012-01-01

    If a series of real numbers converges absolutely, then it converges. The usual proof requires completeness in the form of the Cauchy criterion. Failing completeness, the result is false. We provide examples of rational series that illustrate this point. The Cantor set appears in connection with one of the examples.

  20. Population-based absolute risk estimation with survey data.

    PubMed

    Kovalchik, Stephanie A; Pfeiffer, Ruth M

    2014-04-01

    Absolute risk is the probability that a cause-specific event occurs in a given time interval in the presence of competing events. We present methods to estimate population-based absolute risk from a complex survey cohort that can accommodate multiple exposure-specific competing risks. The hazard function for each event type consists of an individualized relative risk multiplied by a baseline hazard function, which is modeled nonparametrically or parametrically with a piecewise exponential model. An influence method is used to derive a Taylor-linearized variance estimate for the absolute risk estimates. We introduce novel measures of the cause-specific influences that can guide modeling choices for the competing event components of the model. To illustrate our methodology, we build and validate cause-specific absolute risk models for cardiovascular and cancer deaths using data from the National Health and Nutrition Examination Survey. Our applications demonstrate the usefulness of survey-based risk prediction models for predicting health outcomes and quantifying the potential impact of disease prevention programs at the population level. PMID:23686614

  1. Invalid phase values removal method for absolute phase recovery.

    PubMed

    Lu, Jin; Mo, Rong; Sun, Huibin; Chang, Zhiyong; Zhao, Xiaxia

    2016-01-10

    A novel approach is presented for more effectively removing invalid phase values in absolute phase recovery. The approach is based on a detailed study involving the types and cases of invalid phase values. Meanwhile, some commonalities of the existing removal algorithms also are thoroughly analyzed. It is well known that rough absolute phase and fringe order maps can very easily be obtained by temporal phase unwrapping techniques. After carefully analyzing the components and fringe order distribution of the rough fringe order map, the proposed method chiefly adopts an entirely new strategy to refine a pure fringe order map. The strategy consists of three parts: (1) the square of an image gradient, (2) subregion areas of the binary image, and (3) image decomposition and composition. In combination with the pure fringe order map and a removal criterion, the invalid phase values can be identified and filtered out from the rough absolute phase map. This new strategy not only gets rid of the limitations of traditional removal methods but also has a two-fold function. The paper also offers different metrics from the experiment to evaluate the quality of the final absolute phase. In contrast with other removal methods, experimental results have verified the feasibility, effectiveness, and superiority of the proposed method. PMID:26835776

  2. Absolute Value Inequalities: High School Students' Solutions and Misconceptions

    ERIC Educational Resources Information Center

    Almog, Nava; Ilany, Bat-Sheva

    2012-01-01

    Inequalities are one of the foundational subjects in high school math curricula, but there is a lack of academic research into how students learn certain types of inequalities. This article fills part of the research gap by presenting the findings of a study that examined high school students' methods of approaching absolute value inequalities,…

  3. Lyman alpha SMM/UVSP absolute calibration and geocoronal correction

    NASA Technical Reports Server (NTRS)

    Fontenla, Juan M.; Reichmann, Edwin J.

    1987-01-01

    Lyman alpha observations from the Ultraviolet Spectrometer Polarimeter (UVSP) instrument of the Solar Maximum Mission (SMM) spacecraft were analyzed and provide instrumental calibration details. Specific values of the instrument quantum efficiency, Lyman alpha absolute intensity, and correction for geocoronal absorption are presented.

  4. An improved generalized Newton method for absolute value equations.

    PubMed

    Feng, Jingmei; Liu, Sanyang

    2016-01-01

    In this paper, we suggest and analyze an improved generalized Newton method for solving the NP-hard absolute value equations [Formula: see text] when the singular values of A exceed 1. We show that the global and local quadratic convergence of the proposed method. Numerical experiments show the efficiency of the method and the high accuracy of calculation. PMID:27462490

  5. Relative versus Absolute Stimulus Control in the Temporal Bisection Task

    ERIC Educational Resources Information Center

    de Carvalho, Marilia Pinhiero; Machado, Armando

    2012-01-01

    When subjects learn to associate two sample durations with two comparison keys, do they learn to associate the keys with the short and long samples (relational hypothesis), or with the specific sample durations (absolute hypothesis)? We exposed 16 pigeons to an ABA design in which phases A and B corresponded to tasks using samples of 1 s and 4 s,…

  6. Absolute calibration of Landsat instruments using the moon.

    USGS Publications Warehouse

    Kieffer, H.H.; Wildey, R.L.

    1985-01-01

    A lunar observation by Landsat could provide improved radiometric and geometric calibration of both the Thematic Mapper and the Multispectral Scanner in terms of absolute radiometry, determination of the modulation transfer function, and sensitivity to scattered light. A pitch of the spacecraft would be required. -Authors

  7. Absence of absolutely continuous spectrum for random scattering zippers

    NASA Astrophysics Data System (ADS)

    Boumaza, Hakim; Marin, Laurent

    2015-02-01

    A scattering zipper is a system obtained by concatenation of scattering events with equal even number of incoming and outgoing channels. The associated scattering zipper operator is the unitary analog of Jacobi matrices with matrix entries. For infinite identical events and independent and identically distributed random phases, Lyapunov exponents positivity is proved and yields absence of absolutely continuous spectrum by Kotani's theory.

  8. Individual Differences in Absolute and Relative Metacomprehension Accuracy

    ERIC Educational Resources Information Center

    Maki, Ruth H.; Shields, Micheal; Wheeler, Amanda Easton; Zacchilli, Tammy Lowery

    2005-01-01

    The authors investigated absolute and relative metacomprehension accuracy as a function of verbal ability in college students. Students read hard texts, revised texts, or a mixed set of texts. They then predicted their performance, took a multiple-choice test on the texts, and made posttest judgments about their performance. With hard texts,…

  9. Mathematical Model for Absolute Magnetic Measuring Systems in Industrial Applications

    NASA Astrophysics Data System (ADS)

    Fügenschuh, Armin; Fügenschuh, Marzena; Ludszuweit, Marina; Mojsic, Aleksandar; Sokół, Joanna

    2015-09-01

    Scales for measuring systems are either based on incremental or absolute measuring methods. Incremental scales need to initialize a measurement cycle at a reference point. From there, the position is computed by counting increments of a periodic graduation. Absolute methods do not need reference points, since the position can be read directly from the scale. The positions on the complete scales are encoded using two incremental tracks with different graduation. We present a new method for absolute measuring using only one track for position encoding up to micrometre range. Instead of the common perpendicular magnetic areas, we use a pattern of trapezoidal magnetic areas, to store more complex information. For positioning, we use the magnetic field where every position is characterized by a set of values measured by a hall sensor array. We implement a method for reconstruction of absolute positions from the set of unique measured values. We compare two patterns with respect to uniqueness, accuracy, stability and robustness of positioning. We discuss how stability and robustness are influenced by different errors during the measurement in real applications and how those errors can be compensated.

  10. Absolute Radiometer for Reproducing the Solar Irradiance Unit

    NASA Astrophysics Data System (ADS)

    Sapritskii, V. I.; Pavlovich, M. N.

    1989-01-01

    A high-precision absolute radiometer with a thermally stabilized cavity as receiving element has been designed for use in solar irradiance measurements. The State Special Standard of the Solar Irradiance Unit has been built on the basis of the developed absolute radiometer. The Standard also includes the sun tracking system and the system for automatic thermal stabilization and information processing, comprising a built-in microcalculator which calculates the irradiance according to the input program. During metrological certification of the Standard, main error sources have been analysed and the non-excluded systematic and accidental errors of the irradiance-unit realization have been determined. The total error of the Standard does not exceed 0.3%. Beginning in 1984 the Standard has been taking part in a comparison with the Å 212 pyrheliometer and other Soviet and foreign standards. In 1986 it took part in the international comparison of absolute radiometers and standard pyrheliometers of socialist countries. The results of the comparisons proved the high metrological quality of this Standard based on an absolute radiometer.

  11. Multifrequency continuous wave terahertz spectroscopy for absolute thickness determination

    SciTech Connect

    Scheller, Maik; Baaske, Kai; Koch, Martin

    2010-04-12

    We present a tunable multifrequency continuous wave terahertz spectrometer based on two laser diodes, photoconductive antennas, and a coherent detection scheme. The system is employed to determine the absolute thickness of samples utilizing a proposed synthetic difference frequency method to circumvent the 2pi uncertainty known from conventional photomixing systems while preserving a high spatial resolution.

  12. Ion chambers simplify absolute intensity measurements in the vacuum ultraviolet

    NASA Technical Reports Server (NTRS)

    Sampson, J. A. R.

    1966-01-01

    Single or double ion chamber technique measures absolute radiation intensities in the extreme vacuum ultraviolet region of the spectrum. The ion chambers use rare gases as the ion carrier. Photon absorbed by the gas creates one ion pair so a measure of these is a measure of the number of incident photons.

  13. Urey: to measure the absolute age of Mars

    NASA Technical Reports Server (NTRS)

    Randolph, J. E.; Plescia, J.; Bar-Cohen, Y.; Bartlett, P.; Bickler, D.; Carlson, R.; Carr, G.; Fong, M.; Gronroos, H.; Guske, P. J.; Herring, M.; Javadi, H.; Johnson, D. W.; Larson, T.; Malaviarachchi, K.; Sherrit, S.; Stride, S.; Trebi-Ollennu, A.; Warwick, R.

    2003-01-01

    UREY, a proposed NASA Mars Scout mission will, for the first time, measure the absolute age of an identified igneous rock formation on Mars. By extension to relatively older and younger rock formations dated by remote sensing, these results will enable a new and better understanding of Martian geologic history.

  14. Is There a Rule of Absolute Neutralization in Nupe?

    ERIC Educational Resources Information Center

    Krohn, Robert

    1975-01-01

    A previously prosed rule of absolute neutralization (merging underlying low vowels) is eliminated in an alternative analysis including instead a rule that "breaks" the feature matrix of certain low vowels and redistributes the features of each vowel as a sequence of vowel-like transition plus (a). (Author/RM)

  15. Assignment of absolute stereochemistry by computation of optical rotation angles

    NASA Astrophysics Data System (ADS)

    Kondru, Rama Krishna

    We have developed simple wire and molecular orbital models to qualitatively and quantitatively understand optical rotation angles of molecules. We reported the first ab initio theoretical approach to determine the absolute stereochemistry of a complex natural product by calculating molar rotation angles, [M]D. We applied this method for an unambiguous assignment of the absolute stereochemistry of the hennoxazole A. A protocol analogous to population analysis was devised to analyze atomic contributions to the rotation angles for oxiranes, orthoesters, and other organic compounds. The molar rotations for an indoline, an indonone, menthol and menthone were calculated using ab inito methods and compared with experimental values. We reported the first prediction of the absolute configuration of a natural product, i.e. an a priori assignment of the relative and absolute stereochemistry of pitiamide A. Furthermore, we described a strategy that may help to establish structure-function relations for rotation angles by visualizing the electric and magnetic-field perturbations to a molecule's molecular orbitals.

  16. Hitting the target: relatively easy, yet absolutely difficult.

    PubMed

    Mapp, Alistair P; Ono, Hiroshi; Khokhotva, Mykola

    2007-01-01

    It is generally agreed that absolute-direction judgments require information about eye position, whereas relative-direction judgments do not. The source of this eye-position information, particularly during monocular viewing, is a matter of debate. It may be either binocular eye position, or the position of the viewing-eye only, that is crucial. Using more ecologically valid stimulus situations than the traditional LED in the dark, we performed two experiments. In experiment 1, observers threw darts at targets that were fixated either monocularly or binocularly. In experiment 2, observers aimed a laser gun at targets while fixating either the rear or the front gunsight monocularly, or the target either monocularly or binocularly. We measured the accuracy and precision of the observers' absolute- and relative-direction judgments. We found that (a) relative-direction judgments were precise and independent of phoria, and (b) monocular absolute-direction judgments were inaccurate, and the magnitude of the inaccuracy was predictable from the magnitude of phoria. These results confirm that relative-direction judgments do not require information about eye position. Moreover, they show that binocular eye-position information is crucial when judging the absolute direction of both monocular and binocular targets. PMID:17972479

  17. Absolute Risk Aversion and the Returns to Education.

    ERIC Educational Resources Information Center

    Brunello, Giorgio

    2002-01-01

    Uses 1995 Italian household income and wealth survey to measure individual absolute risk aversion of 1,583 married Italian male household heads. Uses this measure as an instrument for attained education in a standard-log earnings equation. Finds that the IV estimate of the marginal return to schooling is much higher than the ordinary least squares…

  18. Improved cavity-type absolute total-radiation radiometer

    NASA Technical Reports Server (NTRS)

    Kendall, J. M., Sr.; Plamondon, J. A., Jr.

    1967-01-01

    Conical cavity-type absolute radiometer measures the intensity of radiant energy to an accuracy of one to two percent in a vacuum of ten to the minus fifth torr or lower. There is a uniform response over the ultraviolet, visible, and infrared range, and it requires no calibration or comparison with a radiation standard.

  19. Absolute Interrogative Intonation Patterns in Buenos Aires Spanish

    ERIC Educational Resources Information Center

    Lee, Su Ar

    2010-01-01

    In Spanish, each uttered phrase, depending on its use, has one of a variety of intonation patterns. For example, a phrase such as "Maria viene manana" "Mary is coming tomorrow" can be used as a declarative or as an absolute interrogative (a yes/no question) depending on the intonation pattern that a speaker produces. Patterns of usage also…

  20. Absolute configurations of zingiberenols isolated from ginger (Zingiber officinale) rhizomes

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The sesquiterpene alcohol zingiberenol, or 1,10-bisaboladien-3-ol, was isolated some time ago from ginger, Zingiber officinale, rhizomes, but its absolute configuration had not been determined. With three chiral centers present in the molecule, zingiberenol can exist in eight stereoisomeric forms. ...

  1. Defining Clinical Excellence in Adult Infectious Disease Practice

    PubMed Central

    Chida, Natasha M.; Ghanem, Khalil G.; Auwaerter, Paul G.; Wright, Scott M.; Melia, Michael T.

    2016-01-01

    Clinical excellence should be recognized, particularly in the current climate that appropriately prioritizes relationship-centered care. In order to develop a recognition model, a definition of clinical excellence must be created and agreed upon. A paradigm recently suggested by C. Christmas describes clinical excellence through the following domains: diagnostic acumen, professionalism and humanism, communication and interpersonal skills, skillful negotiation of the healthcare system, knowledge, taking a scholarly approach to clinical practice, and having passion for clinical medicine. This work references examples of infectious disease (ID) clinical excellence across Christmas' domains and, in doing so, both examines how the definition of clinical excellence applies to ID practice and highlights the importance of ID physicians. Emphasizing such aspirational standards may not only inspire trainees and practicing physicians to pursue their own fulfilling clinical ID careers, it may also encourage health systems to fully value outstanding ID physicians who labor tirelessly to provide patients with exceptional care. PMID:27419186

  2. Defining Clinical Excellence in Adult Infectious Disease Practice.

    PubMed

    Chida, Natasha M; Ghanem, Khalil G; Auwaerter, Paul G; Wright, Scott M; Melia, Michael T

    2016-09-01

    Clinical excellence should be recognized, particularly in the current climate that appropriately prioritizes relationship-centered care. In order to develop a recognition model, a definition of clinical excellence must be created and agreed upon. A paradigm recently suggested by C. Christmas describes clinical excellence through the following domains: diagnostic acumen, professionalism and humanism, communication and interpersonal skills, skillful negotiation of the healthcare system, knowledge, taking a scholarly approach to clinical practice, and having passion for clinical medicine. This work references examples of infectious disease (ID) clinical excellence across Christmas' domains and, in doing so, both examines how the definition of clinical excellence applies to ID practice and highlights the importance of ID physicians. Emphasizing such aspirational standards may not only inspire trainees and practicing physicians to pursue their own fulfilling clinical ID careers, it may also encourage health systems to fully value outstanding ID physicians who labor tirelessly to provide patients with exceptional care. PMID:27419186

  3. Award for Excellence in Perioperative Nursing--AORN's ultimate prize.

    PubMed

    Voss, S J

    1992-12-01

    Excellence should be part of our daily practice. Through sharing of knowledge, ideas, and information, private excellence is transformed into public excellence and deserves recognition. AORN recognizes that many individuals have and do make a difference in their individual practice settings as well as by their national influence. The importance of recognizing members for their contributions to perioperative nursing is evidenced by the addition of the two new awards and the many other individual awards given by the Association. The importance of peer recognition and participation in the selection process for the awards cannot be underestimated. The Award for Excellence Committee encourages your continued involvement in the nomination process. Excellence is not just for a chosen few! It is something each of us is capable of doing each day. What we need to do now is to recognize it in ourselves and others and to accord those who display this quality the recognition they deserve. PMID:1463328

  4. Four Years of Absolute Gravity in the Taiwan Orogen (AGTO)

    NASA Astrophysics Data System (ADS)

    Mouyen, Maxime; Masson, Frédéric; Hwang, Cheinway; Cheng, Ching-Chung; Le Moigne, Nicolas; Lee, Chiung-Wu; Kao, Ricky; Hsieh, Nicky

    2010-05-01

    AGTO is a scientific project between Taiwanese and French institutes, which aim is to improve tectonic knowledge of Taiwan primarily using absolute gravity measurements and permanent GPS stations. Both tools are indeed useful to study vertical movements and mass transfers involved in mountain building, a major process in Taiwan located at the convergent margin between Philippine Sea plate and Eurasian plate. This convergence results in two subductions north and south of Taiwan (Ryukyu and Manilla trenches, respectively), while the center is experiencing collision. These processes make Taiwan very active tectonically, as illustrated by numerous large earthquakes and rapid uplift of the Central Range. High slopes of Taiwan mountains and heavy rains brought by typhoons together lead to high landslides and mudflows risks. Practically, absolute gravity measurements have been yearly repeated since 2006 along a transect across south Taiwan, from Penghu to Lutao islands, using FG5 absolute gravimeters. This transect contains ten sites for absolute measurements and has been densified in 2008 by incorporating 45 sites for relative gravity measurements with CG5 gravimeters. The last relative and absolute measurements have been performed in November 2009. Most of the absolute sites have been measured with a good accuracy, about 1 or 2 ?Gal. Only the site located in Tainan University has higher standard deviation, due to the city noise. We note that absolute gravity changes seem to follow a trend in every site. However, straightforward tectonic interpretation of these trends is not valuable as many non-tectonic effects are supposed to change g with time, like groundwater or erosion. Estimating and removing these effects leads to a tectonic gravity signal, which has theoretically two origins : deep mass transfers around the site and vertical movements of the station. The latter can be well constrained by permanent GPS stations located close to the measurement pillar. Deep mass

  5. Four Years of Absolute Gravity in the Taiwan Orogen (AGTO)

    NASA Astrophysics Data System (ADS)

    Mouyen, M.; Masson, F.; Hwang, C.; Cheng, C.; Le Moigne, N.; Lee, C.; Kao, R.; Hsieh, N.

    2009-12-01

    AGTO is a scientific project between Taiwanese and French institutes which aim is to improve tectonic knowledge of Taiwan primarily using absolute gravity measurements and permanent GPS stations. Both tools are indeed useful to study vertical movements and mass transfers involved in mountain building, a major process in Taiwan located at the convergent margin between Philippine Sea plate and Eurasian plate. This convergence results in two subductions north and south of Taiwan (Ryukyu and Manilla trenches, respectively), while the center is experiencing collision. These processes make Taiwan very active tectonically, as illustrated by numerous large earthquakes and rapid uplift of the Central Range. High slopes of Taiwan mountains and heavy rains brought by typhoons together lead to high landslides and mudflows risks. Practically, absolute gravity measurements have been yearly repeated since 2006 along a transect across south Taiwan, from Penghu to Lutao island, using FG5 absolute gravimeters. This transect contains ten sites for absolute measurements and has been densified in 2008 by incorporating 45 sites for relative gravity measurements with CG5 gravimeters. At the end of 2009, the relative gravity network will be densified again in its eastern part, i.e. in the Longitudinal Valley and the Central Range. A fourth set of absolute gravity measurements will also be performed at the same period. Most of the absolute sites have been measured with a good accuracy, about 1 or 2 μGal. Only the site located in Tainan University has higher standard deviation, due to the city noise. The stronger change in gravity reaches -7 μGal a -1 west of the Longitudinal Valley and might be explained by tectonic movement along a fault. A large decrease of -5 μGal a-1 is also measured in Tainan city and could be correlated with uplift of this region, also denoted by InSAR, leveling and GPS. Changes occurring in the Central Range are more difficult to interpret due to the small

  6. GNSS Absolute Antenna Calibration at the National Geodetic Survey

    NASA Astrophysics Data System (ADS)

    Mader, G. L.; Bilich, A. L.; Geoghegan, C.

    2011-12-01

    Geodetic GNSS applications routinely demand millimeter precision and extremely high levels of accuracy. To achieve these accuracies, measurement and instrument biases at the centimeter to millimeter level must be understood. One of these biases is the antenna phase center, the apparent point of signal reception for a GNSS antenna. It has been well established that phase center patterns differ between antenna models and manufacturers; additional research suggests that the addition of a radome or the choice of antenna mount can significantly alter those a priori phase center patterns. For the more demanding GNSS positioning applications and especially in cases of mixed-antenna networks, it is all the more important to know antenna phase center variations as a function of both elevation and azimuth in the antenna reference frame and incorporate these models into analysis software. To help meet the needs of the high-precision GNSS community, the National Geodetic Survey (NGS) now operates an absolute antenna calibration facility. Located in Corbin, Virginia, this facility uses field measurements and actual GNSS satellite signals to quantitatively determine the carrier phase advance/delay introduced by the antenna element. The NGS facility was built to serve traditional NGS constituents such as the surveying and geodesy communities, however calibration services are open and available to all GNSS users as the calibration schedule permits. All phase center patterns computed by this facility will be publicly available and disseminated in both the ANTEX and NGS formats. We describe the NGS calibration facility, and discuss the observation models and strategy currently used to generate NGS absolute calibrations. We demonstrate that NGS absolute phase center variation (PCV) patterns are consistent with published values determined by other absolute antenna calibration facilities, and compare absolute calibrations to the traditional NGS relative calibrations.

  7. Absolute Gravity Datum in the Age of Cold Atom Gravimeters

    NASA Astrophysics Data System (ADS)

    Childers, V. A.; Eckl, M. C.

    2014-12-01

    The international gravity datum is defined today by the International Gravity Standardization Net of 1971 (IGSN-71). The data supporting this network was measured in the 1950s and 60s using pendulum and spring-based gravimeter ties (plus some new ballistic absolute meters) to replace the prior protocol of referencing all gravity values to the earlier Potsdam value. Since this time, gravimeter technology has advanced significantly with the development and refinement of the FG-5 (the current standard of the industry) and again with the soon-to-be-available cold atom interferometric absolute gravimeters. This latest development is anticipated to provide improvement in the range of two orders of magnitude as compared to the measurement accuracy of technology utilized to develop ISGN-71. In this presentation, we will explore how the IGSN-71 might best be "modernized" given today's requirements and available instruments and resources. The National Geodetic Survey (NGS), along with other relevant US Government agencies, is concerned about establishing gravity control to establish and maintain high order geodetic networks as part of the nation's essential infrastructure. The need to modernize the nation's geodetic infrastructure was highlighted in "Precise Geodetic Infrastructure, National Requirements for a Shared Resource" National Academy of Science, 2010. The NGS mission, as dictated by Congress, is to establish and maintain the National Spatial Reference System, which includes gravity measurements. Absolute gravimeters measure the total gravity field directly and do not involve ties to other measurements. Periodic "intercomparisons" of multiple absolute gravimeters at reference gravity sites are used to constrain the behavior of the instruments to ensure that each would yield reasonably similar measurements of the same location (i.e. yield a sufficiently consistent datum when measured in disparate locales). New atomic interferometric gravimeters promise a significant

  8. Absolute magnitudes and phase coefficients of trans-Neptunian objects

    NASA Astrophysics Data System (ADS)

    Alvarez-Candal, A.; Pinilla-Alonso, N.; Ortiz, J. L.; Duffard, R.; Morales, N.; Santos-Sanz, P.; Thirouin, A.; Silva, J. S.

    2016-02-01

    Context. Accurate measurements of diameters of trans-Neptunian objects (TNOs) are extremely difficult to obtain. Thermal modeling can provide good results, but accurate absolute magnitudes are needed to constrain the thermal models and derive diameters and geometric albedos. The absolute magnitude, HV, is defined as the magnitude of the object reduced to unit helio- and geocentric distances and a zero solar phase angle and is determined using phase curves. Phase coefficients can also be obtained from phase curves. These are related to surface properties, but only few are known. Aims: Our objective is to measure accurate V-band absolute magnitudes and phase coefficients for a sample of TNOs, many of which have been observed and modeled within the program "TNOs are cool", which is one of the Herschel Space Observatory key projects. Methods: We observed 56 objects using the V and R filters. These data, along with those available in the literature, were used to obtain phase curves and measure V-band absolute magnitudes and phase coefficients by assuming a linear trend of the phase curves and considering a magnitude variability that is due to the rotational light-curve. Results: We obtained 237 new magnitudes for the 56 objects, six of which were without previously reported measurements. Including the data from the literature, we report a total of 110 absolute magnitudes with their respective phase coefficients. The average value of HV is 6.39, bracketed by a minimum of 14.60 and a maximum of -1.12. For the phase coefficients we report a median value of 0.10 mag per degree and a very large dispersion, ranging from -0.88 up to 1.35 mag per degree.

  9. A Tutorial on the Use of Excel 2010 and Excel for Mac 2011 for Conducting Delay-Discounting Analyses

    ERIC Educational Resources Information Center

    Reed, Derek D.; Kaplan, Brent A.; Brewer, Adam T.

    2012-01-01

    In recent years, researchers and practitioners in the behavioral sciences have profited from a growing literature on delay discounting. The purpose of this article is to provide readers with a brief tutorial on how to use Microsoft Office Excel 2010 and Excel for Mac 2011 to analyze discounting data to yield parameters for both the hyperbolic…

  10. Creating a Continuum of Excellence: A U.S. Blue Ribbon Schools of Excellence Conference Proceedings (Coral Gables, Florida, 1999).

    ERIC Educational Resources Information Center

    Nalley, Donna

    These proceedings of the conference "Creating a Continuum of Excellence: A U.S. Blue Ribbon Schools of Excellence Conference," produced by SERVE in collaboration with Nova Southeastern University was held in Coral Gables, Florida, 1999. It lists keynote speakers, action planning meetings, think tanks, and titles of exemplary practice sessions, as…

  11. In situ TDLAS measurement of absolute acetylene concentration profiles in a non-premixed laminar counter-flow flame

    NASA Astrophysics Data System (ADS)

    Wagner, S.; Klein, M.; Kathrotia, T.; Riedel, U.; Kissel, T.; Dreizler, A.; Ebert, V.

    2012-06-01

    Acetylene (C2H2), as an important precursor for chemiluminescence species, is a key to understand, simulate and model the chemiluminescence and the related reaction paths. Hence we developed a high resolution spectrometer based on direct Tunable Diode Laser Absorption Spectroscopy (TDLAS) allowing the first quantitative, calibration-free and spatially resolved in situ C2H2 measurement in an atmospheric non-premixed counter-flow flame supported on a Tsuji burner. A fiber-coupled distributed feedback diode laser near 1535 nm was used to measure several absolute C2H2 concentration profiles (peak concentrations up to 9700 ppm) in a laminar non-premixed CH4/air flame ( T up to 1950 K) supported on a modified Tsuji counter-flow burner with N2 purge slots to minimize end flames. We achieve a fractional optical resolution of up to 5×10-5 OD (1 σ) in the flame, resulting in temperature-dependent acetylene detection limits for the P17e line at 6513 cm-1 of up to 2.1 ppmṡm. Absolute C2H2 concentration profiles were obtained by translating the burner through the laser beam using a DC motor with 100 μm step widths. Intercomparisons of the experimental C2H2 profiles with simulations using our new hydrocarbon oxidation mechanisms show excellent agreement in position, shape and in the absolute C2H2 values.

  12. The realization of the dipole (γ, γ) method and its application to determine the absolute optical oscillator strengths of helium

    PubMed Central

    Xu, Long-Quan; Liu, Ya-Wei; Kang, Xu; Ni, Dong-Dong; Yang, Ke; Hiraoka, Nozomu; Tsuei, Ku-Ding; Zhu, Lin-Fan

    2015-01-01

    The dipole (γ, γ) method, which is the inelastic x-ray scattering operated at a negligibly small momentum transfer, is proposed and realized to determine the absolute optical oscillator strengths of the vanlence-shell excitations of atoms and molecules. Compared with the conventionally used photoabsorption method, this new method is free from the line saturation effect, which can seriously limit the accuracies of the measured photoabsorption cross sections for discrete transitions with narrow natural linewidths. Furthermore, the Bethe-Born conversion factor of the dipole (γ, γ) method varies much more slowly with the excitation energy than does that of the dipole (e, e) method. Absolute optical oscillator strengths for the excitations of 1s2 → 1 snp(n = 3 − 7) of atomic helium have been determined using the high-resolution dipole (γ, γ) method, and the excellent agreement of the present measurements with both those measured by the dipole (e, e) method and the previous theoretical calculations indicates that the dipole (γ, γ) method is a powerful tool to measure the absolute optical oscillator strengths of the valence-shell excitations of atoms and molecules. PMID:26678298

  13. Excel2Genie: A Microsoft Excel application to improve the flexibility of the Genie-2000 Spectroscopic software.

    PubMed

    Forgács, Attila; Balkay, László; Trón, Lajos; Raics, Péter

    2014-12-01

    Excel2Genie, a simple and user-friendly Microsoft Excel interface, has been developed to the Genie-2000 Spectroscopic Software of Canberra Industries. This Excel application can directly control Canberra Multichannel Analyzer (MCA), process the acquired data and visualize them. Combination of Genie-2000 with Excel2Genie results in remarkably increased flexibility and a possibility to carry out repetitive data acquisitions even with changing parameters and more sophisticated analysis. The developed software package comprises three worksheets: display parameters and results of data acquisition, data analysis and mathematical operations carried out on the measured gamma spectra. At the same time it also allows control of these processes. Excel2Genie is freely available to assist gamma spectrum measurements and data evaluation by the interested Canberra users. With access to the Visual Basic Application (VBA) source code of this application users are enabled to modify the developed interface according to their intentions. PMID:25113536

  14. Chasing Perfection and Catching Excellence in Graduate Medical Education.

    PubMed

    Andolsek, Kathryn M

    2015-09-01

    The author reflects on the chapter titled "Preserving Excellence in Residency Training and Medical Care" in Dr. Kenneth Ludmerer's book Let Me Heal: The Opportunity to Preserve Excellence in American Medicine. Rather than assuming that the status quo represents excellence, however, the author asserts that we must make an informed judgment regarding the quality of graduate medical education (GME) by applying an evidence-based approach, carefully measuring performance against specific criteria. But what are the right criteria to judge excellence in GME? The author posits that the first criterion for excellence is the foundational concept identified by the Josiah Macy Jr. Foundation, that of accountability to the public. The author argues that for GME to be truly excellent it must produce a workforce "of sufficient size, specialty mix, and skill" needed to serve the public good. For GME to be truly excellent it must produce the right composition (reflecting the population it serves), use the right pedagogy, and be embedded within the right clinical learning environment. Implementation of competency-based education must be bolder and accelerated. The process of culling out service from education in GME must be more honest, not because all service cannot in some ways be educational but because it is simply too expensive to squander a single minute of time in training. Finally, the epidemic of burnout must be addressed urgently and innovatively. PMID:26177530

  15. Clinical Excellence in Psychiatry: A Review of the Psychiatric Literature

    PubMed Central

    Chisolm, Margaret S.; Peters, Matthew E.; Burkhart, Kathleen

    2012-01-01

    Objective: The provision of excellent patient care is a goal that physicians would like to achieve in caring for all patients, all of the time. Until recently, clinical excellence had not been defined, and the extent to which this recently published definition applies to the care of patients with psychiatric illness is not known. This article sets out to consider how the paradigm for clinical excellence applies to the field of psychiatry. Data Source: PubMed, Ovid MEDLINE, and PsycINFO were searched (1962 through December 2010) combining the keywords psychiatry (or psychiatrist) and clinical excellence, limiting the output to English-language case reports. In subsequent searches, the term clinical excellence was replaced by each of the components of the definition: communication and interpersonal skills, professionalism and humanism, diagnostic acumen, skillful negotiation of the health care system, knowledge, scholarly approach to clinical practice, exhibiting a passion for patient care, explicitly modeling mastery to medical trainees, and collaborating with investigators to advance science and discovery. Study Selection: The search yielded 218 case reports. All of the case reports were reviewed, and a consensus was reached on the 8 exemplars and 1 teaching model to be presented in the article. Careful consideration was given as to whether any aspects of the framework for clinical excellence were missing or not applicable for psychiatry. Results Every case report reviewed touched on 1 or more of the domains of clinical excellence. None of the case reports uncovered new aspects of clinical excellence that were not described in the existing definition. Conclusions: This review of the case reports published in psychiatry reveals that the definition of clinical excellence described in this article may be highly applicable to those caring for patients with psychiatric illness. PMID:22943033

  16. Absolute charge calibration of scintillating screens for relativistic electron detection

    SciTech Connect

    Buck, A.; Popp, A.; Schmid, K.; Karsch, S.; Krausz, F.; Zeil, K.; Jochmann, A.; Kraft, S. D.; Sauerbrey, R.; Cowan, T.; Schramm, U.; Hidding, B.; Kudyakov, T.; Sears, C. M. S.; Veisz, L.; Pawelke, J.

    2010-03-15

    We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm{sup 2}. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm{sup 2} was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

  17. Absolute calibration for a broad range single shot electron spectrometer

    SciTech Connect

    Glinec, Y.; Faure, J.; Guemnie-Tafo, A.; Malka, V.; Monard, H.; Larbre, J. P.; De Waele, V.; Marignier, J. L.; Mostafavi, M.

    2006-10-15

    This article gives a detailed description of a single shot electron spectrometer which was used to characterize electron beams produced by laser-plasma interaction. Contrary to conventional electron sources, electron beams from laser-plasma accelerators can produce a broad range of energies. Therefore, diagnosing these electron spectra requires specific attention and experimental development. Here, we provide an absolute calibration of the Lanex Kodak Fine screen on a laser-triggered radio frequency picosecond electron accelerator. The efficiency of scintillating screens irradiated by electron beams has never been investigated so far. This absolute calibration is then compared to charge measurements from an integrating current transformer for quasimonoenergetic electron spectra from laser-plasma interaction.

  18. Absolute charge calibration of scintillating screens for relativistic electron detection

    NASA Astrophysics Data System (ADS)

    Buck, A.; Zeil, K.; Popp, A.; Schmid, K.; Jochmann, A.; Kraft, S. D.; Hidding, B.; Kudyakov, T.; Sears, C. M. S.; Veisz, L.; Karsch, S.; Pawelke, J.; Sauerbrey, R.; Cowan, T.; Krausz, F.; Schramm, U.

    2010-03-01

    We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm2. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm2 was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

  19. From Hubble's Next Generation Spectral Library (NGSL) to Absolute Fluxes

    NASA Astrophysics Data System (ADS)

    Heap, S. R.; Lindler, D.

    2016-05-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R˜1000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18–1.03 μ. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsl/. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We have therefore developed an observing procedure, data-reduction procedure, and correction algorithms that should yield fluxes with uncertainties less than 1%.

  20. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    NASA Astrophysics Data System (ADS)

    Sorri, J.; Greenlees, P. T.; Papadakis, P.; Konki, J.; Cox, D. M.; Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J.; Herzberg, R.-D.; Smallcombe, J.; Davies, P. J.; Barton, C. J.; Jenkins, D. G.

    2016-03-01

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of 154Sm, 152Sm and 166Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  1. Absolute magnitude calibration using trigonometric parallax - Incomplete, spectroscopic samples

    NASA Technical Reports Server (NTRS)

    Ratnatunga, Kavan U.; Casertano, Stefano

    1991-01-01

    A new numerical algorithm is used to calibrate the absolute magnitude of spectroscopically selected stars from their observed trigonometric parallax. This procedure, based on maximum-likelihood estimation, can retrieve unbiased estimates of the intrinsic absolute magnitude and its dispersion even from incomplete samples suffering from selection biases in apparent magnitude and color. It can also make full use of low accuracy and negative parallaxes and incorporate censorship on reported parallax values. Accurate error estimates are derived for each of the fitted parameters. The algorithm allows an a posteriori check of whether the fitted model gives a good representation of the observations. The procedure is described in general and applied to both real and simulated data.

  2. In-flight Absolute Radiometric Calibration of the Thematic Mapper

    NASA Technical Reports Server (NTRS)

    Castle, K. R.; Holm, R. G.; Kastner, C. J.; Palmer, J. M.; Slater, P. N.; Dinguirard, M.; Ezra, C. E.; Jackson, D.; Savage, R. K.

    1984-01-01

    The Thematic Mapper (TM) multispectral scanner system was placed into Earth orbit on July 16, 1982, as part of NASA's LANDSAT 4 payload. To determine temporal changes of the absolute radiometric calibration of the entire system in flight, spectroradiometric measurements of the ground and the atmosphere are made simultaneously with TM image acquisitions over the White Sands, New Mexico area. By entering the measured values into an atmospheric radiative transfer program, the radiance levels at the entrance pupil of the TM in four of the TM spectral bands are determined. These levels are compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors. By reference to an adjacent, larger uniform area, the calibration is extended to all 16 detectors in each of the three bands.

  3. Absolute measurement of the extreme UV solar flux

    NASA Technical Reports Server (NTRS)

    Carlson, R. W.; Ogawa, H. S.; Judge, D. L.; Phillips, E.

    1984-01-01

    A windowless rare-gas ionization chamber has been developed to measure the absolute value of the solar extreme UV flux in the 50-575-A region. Successful results were obtained on a solar-pointing sounding rocket. The ionization chamber, operated in total absorption, is an inherently stable absolute detector of ionizing UV radiation and was designed to be independent of effects from secondary ionization and gas effusion. The net error of the measurement is + or - 7.3 percent, which is primarily due to residual outgassing in the instrument, other errors such as multiple ionization, photoelectron collection, and extrapolation to the zero atmospheric optical depth being small in comparison. For the day of the flight, Aug. 10, 1982, the solar irradiance (50-575 A), normalized to unit solar distance, was found to be 5.71 + or - 0.42 x 10 to the 10th photons per sq cm sec.

  4. In-flight absolute radiometric calibration of the thematic mapper

    NASA Technical Reports Server (NTRS)

    Castle, K. R.; Holm, R. G.; Kastner, C. J.; Palmer, J. M.; Slater, P. N.; Dinguirard, M.; Ezra, C. E.; Jackson, R. D.; Savage, R. K.

    1984-01-01

    In order to determine temporal changes of the absolute radiometric calibration of the entire TM system in flight spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM image collections over the White Sands, New Mexico area. By entering the measured values in an atmospheric radiative transfer program, the radiance levels in four of the spectral bands of the TM were determined, band 1:0.45 to 0.52 micrometers, band 2:0.53 to 0.61 micrometers band 3:0.62 to 0.70 micrometers and 4:0.78 to 0.91 micrometers. These levels were compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors.

  5. In-flight absolute radiometric calibration of the Thematic Mapper

    NASA Technical Reports Server (NTRS)

    Castle, K. R.; Holm, R. G.; Kastner, C. J.; Palmer, J. M.; Slater, P. N.; Dinguirard, M.; Ezra, C. E.; Jackson, R. D.; Savage, R. K.

    1984-01-01

    In order to determine temporal changes of the absolute radiometric calibration of the entire TM system in flight spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM image collections over the White Sands, NM area. By entering the measured values in an atmospheric radiative transfer program, the radiance levels in four of the spectral bands of the TM were determined, band 1: 0.45 to 0.52 micrometers, band 2: 0.53 to 0.61 micrometers, band 3: 0.62 to 0.70 micrometers, and 4: 0.78 to 0.91 micrometers. These levels were compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors. Previously announced in STAR as N84-15633

  6. Absolute calibration of vacuum ultraviolet spectrograph system for plasma diagnostics

    SciTech Connect

    Yoshikawa, M.; Kubota, Y.; Kobayashi, T.; Saito, M.; Numada, N.; Nakashima, Y.; Cho, T.; Koguchi, H.; Yagi, Y.; Yamaguchi, N.

    2004-10-01

    A space- and time-resolving vacuum ultraviolet (VUV) spectrograph system has been applied to diagnose impurity ions behavior in plasmas produced in the tandem mirror GAMMA 10 and the reversed field pinch TPE-RX. We have carried out ray tracing calculations for obtaining the characteristics of the VUV spectrograph and calibration experiments to measure the absolute sensitivities of the VUV spectrograph system for the wavelength range from 100 to 1100 A. By changing the incident angle, 50.6 deg. -51.4 deg., to the spectrograph whose nominal incident angle is 51 deg., we can change the observing spectral range of the VUV spectrograph. In this article, we show the ray tracing calculation results and absolute sensitivities when the angle of incidence into the VUV spectrograph is changed, and the results of VUV spectroscopic measurement in both GAMMA 10 and TPE-RX plasmas.

  7. Absolute Configurations of Zingiberenols Isolated from Ginger (Zingiber officinale) Rhizomes.

    PubMed

    Khrimian, Ashot; Shirali, Shyam; Guzman, Filadelfo

    2015-12-24

    Two stereoisomeric zingiberenols in ginger were identified as (3R,6R,7S)-1,10-bisaboladien-3-ol (2) and (3S,6R,7S)-1,10-bisaboladien-3-ol (5). Absolute configurations were assigned by utilizing 1,10-bisaboladien-3-ol stereoisomers and two gas-chromatography columns: a 25 m Hydrodex-β-6TBDM and 60 m DB-5MS. The C-6 and C-7 absolute configurations in both zingiberenols match those of zingiberene present abundantly in ginger rhizomes. Interestingly, zingiberenol 2 has recently been identified as a male-produced sex pheromone of the rice stink bug, Oebalus poecilus, thus indicating that ginger plants may be a potential source of the sex pheromone of this bug. PMID:26606508

  8. Absolute limit on rotation of gravitationally bound stars

    SciTech Connect

    Glendenning, N.K.

    1994-03-01

    The authors seek an absolute limit on the rotational period for a neutron star as a function of its mass, based on the minimal constraints imposed by Einstein`s theory of relativity, Le Chatelier`s principle, causality and a low-density equation of state, uncertainties which can be evaluated as to their effect on the result. This establishes a limiting curve in the mass-period plane below which no pulsar that is a neutron star can lie. For example, the minimum possible Kepler period, which is an absolute limit on rotation below which mass-shedding would occur, is 0.33 ms for a M = 1.442 M{circle_dot} neutron star (the mass of PSR1913+16). If the limit were found to be broken by any pulsar, it would signal that the confined hadronic phase of ordinary nucleons and nuclei is only metastable, an extraordinary conclusion.

  9. Validation of GOCE by absolute and relative gravimetry

    NASA Astrophysics Data System (ADS)

    Pettersen, B. R.; Sprlak, M.; Lysaker, D. I.; Omang, O. C. D.; Sekowski, M.; Dykowski, P.

    2012-04-01

    Absolute gravimetry has been performed in 2011 by FG5 and A10 instruments in selected sites of the Norwegian first order gravity network. These observations are used as reference values to transform a large number of relative gravity values collected in 1968-1972. The outcome is a database at current epoch in a reference frame defined by the absolute gravity values. This constitutes our test field for validation of GOCE results. In the test fields, validation of GOCE-derived gravity anomalies was performed. The spectral enhancement method was applied to avoid the spectral inconsistency between the terrestrial and the satellite data. For this purpose, contributions of the EGM2008 model and a gravitational effect of a residual terrain model were calculated.

  10. Proposal for an absolute, atomic definition of mass

    NASA Astrophysics Data System (ADS)

    Wignall, J. W. G.

    1991-11-01

    It is proposed that the mass of a particle be defined absolutely as its de Broglie frequency, measured as the mean de Broglie wavelength of the particle when it has a mean speed (v) and Lorentz factor (gamma); the masses of systems too large to have a measurable de Broglie wavelength mean are then to be derived by specifying the usual inertial and additive properties of mass. This definition avoids the use of an arbitrary macroscopic standard such as the prototype kilogram, and, if present theory is correct, does not even require the choice of a specific particle as a mass standard. Suggestions are made as to how this absolute mass can be realized and measured at the macroscopic level and, finally, some comments are made on the effect of the new definition on the form of the equations of physics.

  11. Absolute phase effects on CPMG-type pulse sequences

    NASA Astrophysics Data System (ADS)

    Mandal, Soumyajit; Oh, Sangwon; Hürlimann, Martin D.

    2015-12-01

    We describe and analyze the effects of transients within radio-frequency (RF) pulses on multiple-pulse NMR measurements such as the well-known Carr-Purcell-Meiboom-Gill (CPMG) sequence. These transients are functions of the absolute RF phases at the beginning and end of the pulse, and are thus affected by the timing of the pulse sequence with respect to the period of the RF waveform. Changes in transients between refocusing pulses in CPMG-type sequences can result in signal decay, persistent oscillations, changes in echo shape, and other effects. We have explored such effects by performing experiments in two different low-frequency NMR systems. The first uses a conventional tuned-and-matched probe circuit, while the second uses an ultra-broadband un-tuned or non-resonant probe circuit. We show that there are distinct differences between the absolute phase effects in these two systems, and present simple models that explain these differences.

  12. Henry More and the development of absolute time.

    PubMed

    Thomas, Emily

    2015-12-01

    This paper explores the nature, development and influence of the first English account of absolute time, put forward in the mid-seventeenth century by the 'Cambridge Platonist' Henry More. Against claims in the literature that More does not have an account of time, this paper sets out More's evolving account and shows that it reveals the lasting influence of Plotinus. Further, this paper argues that More developed his views on time in response to his adoption of Descartes' vortex cosmology and cosmogony, providing new evidence of More's wider project to absorb Cartesian natural philosophy into his Platonic metaphysics. Finally, this paper argues that More should be added to the list of sources that later English thinkers - including Newton and Samuel Clarke - drew on in constructing their absolute accounts of time. PMID:26568082

  13. Improved Absolute Approximation Ratios for Two-Dimensional Packing Problems

    NASA Astrophysics Data System (ADS)

    Harren, Rolf; van Stee, Rob

    We consider the two-dimensional bin packing and strip packing problem, where a list of rectangles has to be packed into a minimal number of rectangular bins or a strip of minimal height, respectively. All packings have to be non-overlapping and orthogonal, i.e., axis-parallel. Our algorithm for strip packing has an absolute approximation ratio of 1.9396 and is the first algorithm to break the approximation ratio of 2 which was established more than a decade ago. Moreover, we present a polynomial time approximation scheme (mathcal{PTAS}) for strip packing where rotations by 90 degrees are permitted and an algorithm for two-dimensional bin packing with an absolute worst-case ratio of 2, which is optimal provided mathcal{P} not= mathcal{NP}.

  14. Flow rate calibration for absolute cell counting rationale and design.

    PubMed

    Walker, Clare; Barnett, David

    2006-05-01

    There is a need for absolute leukocyte enumeration in the clinical setting, and accurate, reliable (and affordable) technology to determine absolute leukocyte counts has been developed. Such technology includes single platform and dual platform approaches. Derivations of these counts commonly incorporate the addition of a known number of latex microsphere beads to a blood sample, although it has been suggested that the addition of beads to a sample may only be required to act as an internal quality control procedure for assessing the pipetting error. This unit provides the technical details for undertaking flow rate calibration that obviates the need to add reference beads to each sample. It is envisaged that this report will provide the basis for subsequent clinical evaluations of this novel approach. PMID:18770842

  15. Enumeration of absolute cell counts using immunophenotypic techniques.

    PubMed

    Mandy, F; Brando, B

    2001-05-01

    Absolute counting of cells or cell subsets has a number of significant clinical applications: monitoring the disease status of HIV-infected patients, enumerating residual white blood cells in leukoreduced blood products, and assessing immunodeficiency in a variety of situations. The single-platform method (flow cytometry alone) has emerged as the method of choice for absolute cell enumeration. This technology counts only the cells of interest in a precisely determined blood volume. Exact cell identification is accomplished by a logical electronic gating algorithm capable of identifying lineage-specific immunofluorescent markers. Exclusion of unwanted cells is automatic. This extensive and detailed unit presents protocols for both volumetric and flow-rate determination of residual white blood cells and of leukocyte subsets. PMID:18770719

  16. Absolute calibration for a broad range single shot electron spectrometer

    NASA Astrophysics Data System (ADS)

    Glinec, Y.; Faure, J.; Guemnie-Tafo, A.; Malka, V.; Monard, H.; Larbre, J. P.; De Waele, V.; Marignier, J. L.; Mostafavi, M.

    2006-10-01

    This article gives a detailed description of a single shot electron spectrometer which was used to characterize electron beams produced by laser-plasma interaction. Contrary to conventional electron sources, electron beams from laser-plasma accelerators can produce a broad range of energies. Therefore, diagnosing these electron spectra requires specific attention and experimental development. Here, we provide an absolute calibration of the Lanex Kodak Fine screen on a laser-triggered radio frequency picosecond electron accelerator. The efficiency of scintillating screens irradiated by electron beams has never been investigated so far. This absolute calibration is then compared to charge measurements from an integrating current transformer for quasimonoenergetic electron spectra from laser-plasma interaction.

  17. Excellence in Computational Biology and Informatics — EDRN Public Portal

    Cancer.gov

    9th Early Detection Research Network (EDRN) Scientific Workshop. Excellence in Computational Biology and Informatics: Sponsored by the EDRN Data Sharing Subcommittee Moderator: Daniel Crichton, M.S., NASA Jet Propulsion Laboratory

  18. The Pathway to Excellence Experience: One Psychiatric Hospital's Journey.

    PubMed

    Mahoney, Jane S; Jackson, Jennifer M; Palyo, Nancy

    2016-01-01

    Psychiatric nurse executives and managers face an ongoing challenge to create positive professional work environments that support the recruitment and retention of the best nurses. The Pathway to Excellence program is an organizational credentialing program that designates a hospital as a workplace of choice for nursing. This article describes one psychiatric hospital's journey to become and maintain a Pathway to Excellence designation in the midst of transition. Challenges faced and novel approaches used, along the journey, are shared. The use of Appreciative Inquiry techniques has led to positive changes and heightened energy among nurses. Our experiences suggest that effective shared governance is central to a hospital's Pathway to Excellence success. We attribute the steady increase in the retention rate of nurses, in large part, to the Pathway to Excellence program. PMID:27259129

  19. Project ProCEED: A Model for Developing Professional Excellence.

    ERIC Educational Resources Information Center

    Miller, Marilyn; Waddell, Michael G.

    1984-01-01

    Project ProCEED is a staff development model for promoting the type of professional excellence recommended in national educational reports. A six-month program designed and implemented by teachers and principals is examined. (DF)

  20. AECT Convention "Third Century Imperative: Excellence in Education"

    ERIC Educational Resources Information Center

    Audiovisual Instruction, 1977

    1977-01-01

    AECT Conference Report, Spring 1977, included: (1) First General Session: The Concept of Instructional Development-Evolution or Revolution? (2) Second General Session: AECT's Role in Educational Excellence, and (3) Third General Session: Alex Haley on Roots. (STS)

  1. Hotel shows health system keys to service excellence.

    PubMed

    2003-08-01

    Ritz-Carlton partnership part of broader program pursuing service excellence. Nearly 600 system leaders will participate in day-long seminars. GE, Harvard serve as strategic partners for ongoing educational efforts. PMID:12901319

  2. The computerized OMAHA system in microsoft office excel.

    PubMed

    Lai, Xiaobin; Wong, Frances K Y; Zhang, Peiqiang; Leung, Carenx W Y; Lee, Lai H; Wong, Jessica S Y; Lo, Yim F; Ching, Shirley S Y

    2014-01-01

    The OMAHA System was adopted as the documentation system in an interventional study. To systematically record client care and facilitate data analysis, two Office Excel files were developed. The first Excel file (File A) was designed to record problems, care procedure, and outcomes for individual clients according to the OMAHA System. It was used by the intervention nurses in the study. The second Excel file (File B) was the summary of all clients that had been automatically extracted from File A. Data in File B can be analyzed directly in Excel or imported in PASW for further analysis. Both files have four parts to record basic information and the three parts of the OMAHA System. The computerized OMAHA System simplified the documentation procedure and facilitated the management and analysis of data. PMID:24943560

  3. Absolute GNSS Antenna Calibration at the National Geodetic Survey

    NASA Astrophysics Data System (ADS)

    Mader, G.; Bilich, A.; Geoghegan, C.

    2012-04-01

    Geodetic GNSS applications routinely demand millimeter precision and extremely high levels of accuracy. To achieve these accuracies, measurement and instrument biases at the centimeter to millimeter level must be understood. One of these biases is the antenna phase center, the apparent point of signal reception for a GNSS antenna. It has been well established that phase center patterns differ between antenna models and manufacturers; additional research suggests that the addition of a radome or the choice of antenna mount can significantly alter those a priori phase center patterns. For the more demanding GNSS positioning applications and especially in cases of mixed-antenna networks, it is all the more important to know antenna phase center variations as a function of both elevation and azimuth in the antenna reference frame and incorporate these models into analysis software. To help meet the needs of the high-precision GNSS community, the National Geodetic Survey (NGS) now operates an absolute antenna calibration facility. Located in Corbin, Virginia, this facility uses field measurements and actual GNSS satellite signals to quantitatively determine the carrier phase advance/delay introduced by the antenna element. The NGS facility was built to serve traditional NGS constituents such as the surveying and geodesy communities, however calibration services are open and available to all GNSS users as the calibration schedule permits. All phase center patterns computed by this facility will be publicly available and disseminated in both the ANTEX and NGS formats. We describe the NGS calibration facility, and discuss the observation models and strategy currently used to generate NGS absolute calibrations. We demonstrate that NGS absolute phase center variation (PCV) patterns are consistent with published values determined by other absolute antenna calibration facilities, and outline future planned refinements to the system.

  4. Engine performance and the determination of absolute ceiling

    NASA Technical Reports Server (NTRS)

    Diehl, Walter S

    1924-01-01

    This report contains a brief study of the variation of engine power with temperature and pressure. The variation of propeller efficiency in standard atmosphere is obtained from the general efficiency curve which is developed in NACA report no. 168. The variation of both power available and power required are then determined and curves plotted, so that the absolute ceiling may be read directly from any known sea-level value of the ratio of power available to power required.

  5. On the Absolute Continuity of the Blackwell Measure

    NASA Astrophysics Data System (ADS)

    Bárány, Balázs; Kolossváry, István

    2015-04-01

    In 1957, Blackwell expressed the entropy of hidden Markov chains using a measure which can be characterised as an invariant measure for an iterated function system with place-dependent weights. This measure, called the Blackwell measure, plays a central role in understanding the entropy rate and other important characteristics of fundamental models in information theory. We show that for a suitable set of parameter values the Blackwell measure is absolutely continuous for almost every parameter in the case of binary symmetric channels.

  6. Electroweak absolute, meta-, and thermal stability in neutrino mass models

    NASA Astrophysics Data System (ADS)

    Lindner, Manfred; Patel, Hiren H.; Radovčić, Branimir

    2016-04-01

    We analyze the stability of the electroweak vacuum in neutrino mass models containing right-handed neutrinos or fermionic isotriplets. In addition to considering absolute stability, we place limits on the Yukawa couplings of new fermions based on metastability and thermal stability in the early Universe. Our results reveal that the upper limits on the neutrino Yukawa couplings can change significantly when the top quark mass is allowed to vary within the experimental range of uncertainty in its determination.

  7. Successful treatment of pyogenic granuloma with injection of absolute ethanol.

    PubMed

    Ichimiya, Makoto; Yoshikawa, Yoshiaki; Hamamoto, Yoshiaki; Muto, Masahiko

    2004-04-01

    Pyogenic granuloma (PG) is a small, almost always solitary, sessile or pedunculated, raspberry-like vegetation of exuberant granulation tissue. Conservative treatment by techniques such as cryosurgery, laser surgery, and electrodesiccation are usually adequate, whereas excisional treatment can often result in noticeable scars. We attempted a different approach using an injection of absolute ethanol in five patients with recurrence due to inadequate cryosurgery. This therapy is less invasive than surgical excision and appears to be an alternative therapy for PG. PMID:15187331

  8. Diagnostic Application of Absolute Neutron Activation Analysis in Hematology

    SciTech Connect

    Zamboni, C.B.; Oliveira, L.C.; Dalaqua, L. Jr.

    2004-10-03

    The Absolute Neutron Activation Analysis (ANAA) technique was used to determine element concentrations of Cl and Na in blood of healthy group (male and female blood donators), select from Blood Banks at Sao Paulo city, to provide information which can help in diagnosis of patients. This study permitted to perform a discussion about the advantages and limitations of using this nuclear methodology in hematological examinations.

  9. Absolute intensity of radiation emitted by uranium plasmas

    NASA Technical Reports Server (NTRS)

    Jalufka, N. W.; Lee, J. H.; Mcfarland, D. R.

    1975-01-01

    The absolute intensity of radiation emitted by fissioning and nonfissioning uranium plasmas in the spectral range from 350 nm to 1000 nm was measured. The plasma was produced in a plasma-focus apparatus and the plasma properties are simular to those anticipated for plasma-core nuclear reactors. The results are expected to contribute to the establishment of design criteria for the development of plasma-core reactors.

  10. THE ABSOLUTE MAGNITUDES OF TYPE Ia SUPERNOVAE IN THE ULTRAVIOLET

    SciTech Connect

    Brown, Peter J.; Roming, Peter W. A.; Ciardullo, Robin; Gronwall, Caryl; Hoversten, Erik A.; Pritchard, Tyler; Milne, Peter; Bufano, Filomena; Mazzali, Paolo; Elias-Rosa, Nancy; Filippenko, Alexei V.; Li Weidong; Foley, Ryan J.; Hicken, Malcolm; Kirshner, Robert P.; Gehrels, Neil; Holland, Stephen T.; Immler, Stefan; Phillips, Mark M.; Still, Martin

    2010-10-01

    We examine the absolute magnitudes and light-curve shapes of 14 nearby (redshift z = 0.004-0.027) Type Ia supernovae (SNe Ia) observed in the ultraviolet (UV) with the Swift Ultraviolet/Optical Telescope. Colors and absolute magnitudes are calculated using both a standard Milky Way extinction law and one for the Large Magellanic Cloud that has been modified by circumstellar scattering. We find very different behavior in the near-UV filters (uvw1{sub rc} covering {approx}2600-3300 A after removing optical light, and u {approx} 3000-4000 A) compared to a mid-UV filter (uvm2 {approx}2000-2400 A). The uvw1{sub rc} - b colors show a scatter of {approx}0.3 mag while uvm2-b scatters by nearly 0.9 mag. Similarly, while the scatter in colors between neighboring filters is small in the optical and somewhat larger in the near-UV, the large scatter in the uvm2 - uvw1 colors implies significantly larger spectral variability below 2600 A. We find that in the near-UV the absolute magnitudes at peak brightness of normal SNe Ia in our sample are correlated with the optical decay rate with a scatter of 0.4 mag, comparable to that found for the optical in our sample. However, in the mid-UV the scatter is larger, {approx}1 mag, possibly indicating differences in metallicity. We find no strong correlation between either the UV light-curve shapes or the UV colors and the UV absolute magnitudes. With larger samples, the UV luminosity might be useful as an additional constraint to help determine distance, extinction, and metallicity in order to improve the utility of SNe Ia as standardized candles.

  11. Absolute partial decay branching-ratios in 16O

    NASA Astrophysics Data System (ADS)

    Wheldon, C.; Ashwood, N. I.; Barr, M.; Curtis, N.; Freer, M.; Kokalova, Tz; Malcolm, J. D.; Spencer, S. J.; Ziman, V. A.; Faestermann, Th; Krücken, R.; Wirth, H.-F.; Hertenberger, R.; Lutter, R.; Bergmaier, A.

    2013-04-01

    The a-transfer reaction 126C(63Li, d)168O* has been performed at a 6Li bombarding energy of 42 MeV to populate excited states in 13C and 16O. Absolute branching ratios have been unambiguously determined for states in the excitation energy range 13.85 to 15.87 MeV and reduced widths are extracted.

  12. The Electromotive Series and Other Non-Absolute Scales

    NASA Astrophysics Data System (ADS)

    Peckham, Gavin D.

    1998-01-01

    This article describes an analogy which may be used to illustrate the principles that underlie the establishment of non-absolute scales of measurements that are evaluated relative to a chosen reference point. The analogy is interwoven with the establishment of the electromotive series, but may be extended to other parameters such as the Celsius and Fahrenheit temperature scales, potential energies, formation and reaction enthalpies, etc.

  13. On the Absolutely Continuous Spectrum of Stark Operators

    NASA Astrophysics Data System (ADS)

    Perelman, Galina

    The stability of the absolutely continuous spectrum of the one-dimensional Stark operator under perturbations of the potential is discussed. The focus is on proving this stability under minimal assumptions on smoothness of the perturbation. A general criterion is presented together with some applications. These include the case of periodic perturbations where we show that any perturbation vL1()∩H-1/2() preserves the a.c. spectrum.

  14. Overspecification of color, pattern, and size: salience, absoluteness, and consistency

    PubMed Central

    Tarenskeen, Sammie; Broersma, Mirjam; Geurts, Bart

    2015-01-01

    The rates of overspecification of color, pattern, and size are compared, to investigate how salience and absoluteness contribute to the production of overspecification. Color and pattern are absolute and salient attributes, whereas size is relative and less salient. Additionally, a tendency toward consistent responses is assessed. Using a within-participants design, we find similar rates of color and pattern overspecification, which are both higher than the rate of size overspecification. Using a between-participants design, however, we find similar rates of pattern and size overspecification, which are both lower than the rate of color overspecification. This indicates that although many speakers are more likely to include color than pattern (probably because color is more salient), they may also treat pattern like color due to a tendency toward consistency. We find no increase in size overspecification when the salience of size is increased, suggesting that speakers are more likely to include absolute than relative attributes. However, we do find an increase in size overspecification when mentioning the attributes is triggered, which again shows that speakers tend to refer in a consistent manner, and that there are circumstances in which even size overspecification is frequently produced. PMID:26594190

  15. Measurement of Absolute Carbon Isotope Ratios: Mechanisms and Implications

    NASA Astrophysics Data System (ADS)

    Vogel, J. S.; Giacomo, J. A.; Dueker, S. R.

    2012-12-01

    An accelerator mass spectrometer (AMS) produced absolute isotope ratio measurements for 14C/13C as tested against >500 samples of NIST SRM-4990-C (OxII 14C standard) to an accuracy of 2.2±0.6‰ over a period of one year with measurements made to 1% counting statistics. The spectrometer is not maximized for 13C/12C, but measured ∂13C to 0.4±0.1‰ accuracy, with known methods for improvement. An AMS produces elemental anions from a sputter ion source and includes a charge-changing collision in a gas cell to isolate the rare 14C from the common isotopes and molecular isobars. Both these physical processes have been modeled to determine the parameters providing such absolute measures. Neutral resonant ionization in a cesium plasma produces mass-independent ionization, while velocity dependent charge-state distributions in gas collisions produce relative ion beam intensities that are linear in mass at specific collision energies. The mechanisms are not specific to carbon isotopes, but stand alone absolute IRMS (AIR-MS) instruments have not yet been made. Aside from the obvious applications in metrology, AIR-MS is particularly valuable in coupled separatory MS because no internal or external standards are required. Sample definition processes can be compared, even if no exact standard reference sample exists. Isotope dilution measurements do not require standards matching the dilution end-points and can be made over an extended, even extrapolated, range.

  16. Peripheral absolute threshold spectral sensitivity in retinitis pigmentosa.

    PubMed Central

    Massof, R W; Johnson, M A; Finkelstein, D

    1981-01-01

    Dark-adapted spectral sensitivities were measured in the peripheral retinas of 38 patients diagnosed as having typical retinitis pigmentosa (RP) and in 3 normal volunteers. The patients included those having autosomal dominant and autosomal recessive inheritance patterns. Results were analysed by comparisons with the CIE standard scotopic spectral visibility function and with Judd's modification of the photopic spectral visibility function, with consideration of contributions from changes in spectral transmission of preretinal media. The data show 3 general patterns. One group of patients had absolute threshold spectral sensitivities that were fit by Judd's photopic visibility curve. Absolute threshold spectral sensitivities for a second group of patients were fit by a normal scotopic spectral visibility curve. The third group of patients had absolute threshold spectral sensitivities that were fit by a combination of scotopic and photopic spectral visibility curves. The autosomal dominant and autosomal recessive modes of inheritance were represented in each group of patients. These data indicate that RP patients have normal rod and/or cone spectral sensitivities, and support the subclassification of patients described previously by Massof and Finkelstein. PMID:7459312

  17. Absolute orientations from EBSD measurements - as easy as it seems?

    NASA Astrophysics Data System (ADS)

    Kilian, Rüdiger; Bestmann, Michel; Heilbronner, Renée

    2016-04-01

    In structural geology, some problems can be addressed by inspecting the crystal orientation of grains in a rock. Deriving shear senses, kinematics of flow, information on deformation processes and recrystallization are some examples. Usually, oriented samples are taken in the field and, if inspected in an universal stage, the researcher has full control over the procedure and can make sure that the derived orientation is related to our geographic reference frame - that it is an absolute orientation. Nowadays, usage of electron backscatter diffraction (EBSD) has greatly improved the information in the derived data (fully crystal orientations, mappings, etc…), and the speed of data acquisition. However, this comes to the price of having to rely on the vendor supplied software and machine setup. Recent benchmarks and comparison of reference data revealed that for various EBSD setups around the world, the orientation data defaults to the wrong absolute orientation. The absolute orientation is not correctly derived - it commonly suffer a 180 degree rotation around the normal of the sample surface. In this contribution we will discuss the implications of such erroneous measurements and what kind of interpretations derived by orientation and texture data will be affected.

  18. Determination of absolute structure using Bayesian statistics on Bijvoet differences

    PubMed Central

    Hooft, Rob W. W.; Straver, Leo H.; Spek, Anthony L.

    2008-01-01

    A new probabilistic approach is introduced for the determination of the absolute structure of a compound which is known to be enantiopure based on Bijvoet-pair intensity differences. The new method provides relative probabilities for different models of the chiral composition of the structure. The outcome of this type of analysis can also be cast in the form of a new value, along with associated standard uncertainty, that resembles the value of the well known Flack x parameter. The standard uncertainty we obtain is often about half of the standard uncertainty in the value of the Flack x parameter. The proposed formalism is suited in particular to absolute configuration determination from diffraction data of biologically active (pharmaceutical) compounds where the strongest resonant scattering signal often comes from oxygen. It is shown that a reliable absolute configuration assignment in such cases can be made on the basis of Cu Kα data, and in some cases even with carefully measured Mo Kα data. PMID:19461838

  19. Son preference in Indian families: absolute versus relative wealth effects.

    PubMed

    Gaudin, Sylvestre

    2011-02-01

    The desire for male children is prevalent in India, where son preference has been shown to affect fertility behavior and intrahousehold allocation of resources. Economic theory predicts less gender discrimination in wealthier households, but demographers and sociologists have argued that wealth can exacerbate bias in the Indian context. I argue that these apparently conflicting theories can be reconciled and simultaneously tested if one considers that they are based on two different notions of wealth: one related to resource constraints (absolute wealth), and the other to notions of local status (relative wealth). Using cross-sectional data from the 1998-1999 and 2005-2006 National Family and Health Surveys, I construct measures of absolute and relative wealth by using principal components analysis. A series of statistical models of son preference is estimated by using multilevel methods. Results consistently show that higher absolute wealth is strongly associated with lower son preference, and the effect is 20%-40% stronger when the household's community-specific wealth score is included in the regression. Coefficients on relative wealth are positive and significant although lower in magnitude. Results are robust to using different samples, alternative groupings of households in local areas, different estimation methods, and alternative dependent variables. PMID:21302027

  20. Absolute Performance of AUSGeoid09 in Mountainous Regions

    NASA Astrophysics Data System (ADS)

    Sussanna, Vittorio; Janssen, Volker; Gibbings, Peter

    2014-09-01

    The Australian Height Datum (AHD) is the current national vertical datum for Australia, and AUSGeoid09 is the latest quasigeoid model used to compute (normal-orthometric)AHDheights fromGlobalNavigation Satellite System (GNSS) derived ellipsoidal heights. While previous studies have evaluated the AUSGeoid09 model across Australia, such studies have not focused on mountainous regions in particular. This paper investigates the performance of AUSGeoid09 in an absolute sense in the Mid Hunter and Snowy Mountains regions of New South Wales. Absolute (i.e. single point) comparisons were undertaken between AUSGeoid09-derived heights and published AHD heights. The performance of AUSGeoid09 was evaluated relative to its predecessor AUSGeoid98. In both study areas, an overall improvement is evident when applying AUSGeoid09 to compute AHD heights in an absolute sense. In the MidHunter, AUSGeoid09 provided a substantial improvement over its predecessor, clearly demonstrating the benefits of its new geometric component on GNSS-derived AHD height determination. In the Snowy Mountains, moderate improvement over AUSGeoid98 was evident. However, a slope was detected for AUSGeoid09 residuals, and it appears that the geometric component may have overcompensated for sea surface topography in this area. While this appraisal of AUSGeoid09 performance in mountainous regions is encouraging, it has been shown that some discrepancies still remain between AUSGeoid09-derived heights and AHD. Eventually, a new vertical datum will be necessary to ensure homogeneity across Australia.