Sample records for absolute detection efficiency

  1. Absolute calibration of a multichannel plate detector for low energy O, O-, and O+

    NASA Astrophysics Data System (ADS)

    Stephen, T. M.; Peko, B. L.

    2000-03-01

    Absolute detection efficiencies of a commercial multichannel plate detector have been measured for O, O+, and O-, impacting at normal incidence for energies ranging from 30-1000 eV. In addition, the detection efficiencies for O relative to its ions are presented, as they may have a more universal application. The absolute detection efficiencies are strongly energy dependent and significant differences are observed for the various charge states at lower energies. The detection efficiencies for the different charge states appear to converge at higher energies. The strongest energy dependence is for O+; the detection efficiency varies by three orders of magnitude across the energy range studied. The weakest dependence is for O-, which varies less than one order of magnitude.

  2. Absolute ion detection efficiencies of microchannel plates and funnel microchannel plates for multi-coincidence detection

    NASA Astrophysics Data System (ADS)

    Fehre, K.; Trojanowskaja, D.; Gatzke, J.; Kunitski, M.; Trinter, F.; Zeller, S.; Schmidt, L. Ph. H.; Stohner, J.; Berger, R.; Czasch, A.; Jagutzki, O.; Jahnke, T.; Dörner, R.; Schöffler, M. S.

    2018-04-01

    Modern momentum imaging techniques allow for the investigation of complex molecules in the gas phase by detection of several fragment ions in coincidence. For these studies, it is of great importance that the single-particle detection efficiency ɛ is as high as possible, as the overall efficiency scales with ɛn, i.e., the power of the number of detected particles. Here we present measured absolute detection efficiencies for protons of several micro-channel plates (MCPs), including efficiency enhanced "funnel MCPs." Furthermore, the relative detection efficiency for two-, three-, four-, and five-body fragmentation of CHBrClF has been examined. The "funnel" MCPs exhibit an efficiency of approximately 90%, gaining a factor of 24 (as compared to "normal" MCPs) in the case of a five-fold ion coincidence detection.

  3. Absolute detection efficiencies of low energy H, H -, H +, H 2+ and H 3+ incident on a multichannel plate detector

    NASA Astrophysics Data System (ADS)

    Peko, B. L.; Stephen, T. M.

    2000-12-01

    Measured absolute detection efficiencies are presented for H, H - and H n+ ( n=1,2,3) impacting a commercially available, dual multichannel plate (MCP) electron multiplier at kinetic energies ranging from 30 to 1000 eV. Measurements involving isotopic substitutions (D, D -, D n+) and Ar + are also presented. In addition, atomic hydrogen detection efficiencies relative to those of H + and H - are given, as they may have a more universal application. For the three charge states, H, H + and H -, the absolute detection efficiencies are markedly different at low energies and converge to a nearly uniform value of ˜70% with increasing projectile energy. The energy dependence is strongest for H +, varying nearly three orders of magnitude over the energy range studied, and weakest for H -, varying by less than one order of magnitude. In general, for the low energy positive ions at a given energy, the lighter the incident particle mass, the greater the probability of its detection.

  4. Experimental feasibility of the airborne measurement of absolute oil fluorescence spectral conversion efficiency

    NASA Technical Reports Server (NTRS)

    Hoge, F. E.; Swift, R. N.

    1983-01-01

    Airborne lidar oil spill experiments carried out to determine the practicability of the AOFSCE (absolute oil fluorescence spectral conversion efficiency) computational model are described. The results reveal that the model is suitable over a considerable range of oil film thicknesses provided the fluorescence efficiency of the oil does not approach the minimum detection sensitivity limitations of the lidar system. Separate airborne lidar experiments to demonstrate measurement of the water column Raman conversion efficiency are also conducted to ascertain the ultimate feasibility of converting such relative oil fluorescence to absolute values. Whereas the AOFSCE model is seen as highly promising, further airborne water column Raman conversion efficiency experiments with improved temporal or depth-resolved waveform calibration and software deconvolution techniques are thought necessary for a final determination of suitability.

  5. Absolute and angular efficiencies of a microchannel-plate position-sensitive detector

    NASA Technical Reports Server (NTRS)

    Gao, R. S.; Gibner, P. S.; Newman, J. H.; Smith, K. A.; Stebbings, R. F.

    1984-01-01

    This paper presents a characterization of a commercially available position-sensitive detector of energetic ions and neutrals. The detector consists of two microchannel plates followed by a resistive position-encoding anode. The work includes measurement of absolute efficiencies of H(+), He(+), and O(+) ions in the energy range between 250 and 5000 eV, measurement of relative detection efficiencies as a function of particle impact angle, and a simple method for accurate measurement of the time at which a particle strikes the detector.

  6. Measurement of absolute response functions and detection efficiencies of an NE213 scintillator up to 600 MeV

    NASA Astrophysics Data System (ADS)

    Kajimoto, Tsuyoshi; Shigyo, Nobuhiro; Sanami, Toshiya; Ishibashi, Kenji; Haight, Robert C.; Fotiades, Nikolaos

    2011-02-01

    Absolute neutron response functions and detection efficiencies of an NE213 liquid scintillator that was 12.7 cm in diameter and 12.7 cm in thickness were measured for neutron energies between 15 and 600 MeV at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. The experiment was performed with continuous-energy neutrons on a spallation neutron source by 800-MeV proton incidence. The incident neutron flux was measured using a 238U fission ionization chamber. Measured response functions and detection efficiencies were compared with corresponding calculations using the SCINFUL-QMD code. The calculated and experimental values were in good agreement for data below 70 MeV. However, there were discrepancies in the energy region between 70 and 150 MeV. Thus, the code was partly modified and the revised code provided better agreement with the experimental data.

  7. Rapid, absolute calibration of x-ray filters employed by laser-produced plasma diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, G. V.; Beiersdorfer, P.; Emig, J.

    2008-10-15

    The Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory is being used to absolutely calibrate the transmission efficiency of x-ray filters employed by diodes and spectrometers used to diagnose laser-produced plasmas. EBIT emits strong, discrete monoenergetic lines at appropriately chosen x-ray energies. X rays are detected using the high resolution EBIT Calorimeter Spectrometer (ECS), developed for LLNL at the NASA/Goddard Space Flight Center. X-ray filter transmission efficiency is determined by dividing the x-ray counts detected when the filter is in the line of sight by those detected when out of the line of sight. Verification ofmore » filter thickness can be completed in only a few hours, and absolute efficiencies can be calibrated in a single day over a broad range from about 0.1 to 15 keV. The EBIT calibration lab has been used to field diagnostics (e.g., the OZSPEC instrument) with fully calibrated x-ray filters at the OMEGA laser. Extensions to use the capability for calibrating filter transmission for the DANTE instrument on the National Ignition Facility are discussed.« less

  8. Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

    NASA Technical Reports Server (NTRS)

    Lapson, L. B.; Timothy, J. G.

    1976-01-01

    Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

  9. Conversion of far ultraviolet to visible radiation: absolute measurements of the conversion efficiency of tetraphenyl butadiene

    NASA Astrophysics Data System (ADS)

    Vest, Robert E.; Coplan, Michael A.; Clark, Charles W.

    Far ultraviolet (FUV) scintillation of noble gases is used in dark matter and neutrino research and in neutron detection. Upon collisional excitation, noble gas atoms recombine into excimer molecules that decay by FUV emission. Direct detection of FUV is difficult. Another approach is to convert it to visible light using a wavelength-shifting medium. One such medium, tetraphenyl butadiene (TPB) can be vapor-deposited on substrates. Thus the quality of thin TPB films can be tightly controlled. We have measured the absolute efficiency of FUV-to-visible conversion by 1 μm-thick TPB films vs. FUV wavelengths between 130 and 300 nm, with 1 nm resolution. The energy efficiency of FUV to visible conversion varies between 1% and 5%. We make comparisons with other recent results. Work performed at the NIST SURF III Synchrotron Ultraviolet Radiation Facility,.

  10. Absolute detector calibration using twin beams.

    PubMed

    Peřina, Jan; Haderka, Ondřej; Michálek, Václav; Hamar, Martin

    2012-07-01

    A method for the determination of absolute quantum detection efficiency is suggested based on the measurement of photocount statistics of twin beams. The measured histograms of joint signal-idler photocount statistics allow us to eliminate an additional noise superimposed on an ideal calibration field composed of only photon pairs. This makes the method superior above other approaches presently used. Twin beams are described using a paired variant of quantum superposition of signal and noise.

  11. Measuring Transmission Efficiencies Of Mass Spectrometers

    NASA Technical Reports Server (NTRS)

    Srivastava, Santosh K.

    1989-01-01

    Coincidence counts yield absolute efficiencies. System measures mass-dependent transmission efficiencies of mass spectrometers, using coincidence-counting techniques reminiscent of those used for many years in calibration of detectors for subatomic particles. Coincidences between detected ions and electrons producing them counted during operation of mass spectrometer. Under certain assumptions regarding inelastic scattering of electrons, electron/ion-coincidence count is direct measure of transmission efficiency of spectrometer. When fully developed, system compact, portable, and used routinely to calibrate mass spectrometers.

  12. In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.

    PubMed

    Brusasco, Claudia; Corradi, Francesco; Vargas, Maria; Bona, Margherita; Bruno, Federica; Marsili, Maria; Simonassi, Francesca; Santori, Gregorio; Severgnini, Paolo; Kacmarek, Robert M; Pelosi, Paolo

    2013-11-01

    Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spontaneously breathing tracheostomized patients, in a normothermic model, at different minute ventilations (VE) and supplemental O2 flows. HME efficiency was evaluated using an in vitro lung model at 2 VE (5 and 15 L/min) and 4 supplemental O2 flows (0, 3, 6, and 12 L/min). Wet and dry temperatures of the inspiratory flow were measured, and absolute humidity was calculated. In addition, HME efficiency at 0, 12, and 24 h use was evaluated, as well as resistance to flow at 0 and 24 h. The progressive increase in O2 flow from 0 to 12 L/min was associated with a reduction in temperature and absolute humidity. Under the same conditions, this effect was greater at lower VE. The HME with the best performance provided an absolute humidity of 26 mg H2O/L and a temperature of 27.8 °C. No significant changes in efficiency or resistance were detected during the 24 h evaluation. The efficiency of HMEs in terms of temperature and absolute humidity is significantly affected by O2 supplementation and V(E).

  13. Absolute measurements of fast neutrons using yttrium.

    PubMed

    Roshan, M V; Springham, S V; Rawat, R S; Lee, P; Krishnan, M

    2010-08-01

    Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f(n) approximately 4.1x10(-4) with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10(8) neutrons per discharge.

  14. ELENA MCP detector: absolute detection efficiency for low-energy neutral atoms

    NASA Astrophysics Data System (ADS)

    Rispoli, R.; De Angelis, E.; Colasanti, L.; Vertolli, N.; Orsini, S.; Scheer, J. A.; Mura, A.; Milillo, A.; Wurz, P.; Selci, S.; Di Lellis, A. M.; Leoni, R.; D'Alessandro, M.; Mattioli, F.; Cibella, S.

    2012-09-01

    Microchannel Plates (MCP) detectors are frequently used in space instrumentation for detecting a wide range of radiation and particles. In particular, the capability to detect non-thermal low energy neutral species is crucial for the sensor ELENA (Emitted Low-Energy Neutral Atoms), part of the package SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) on board the BepiColombo mission of ESA to Mercury to be launched in 2015. ELENA is a Time of Flight (TOF) sensor, based on a novel concept using an ultra-sonic oscillating shutter (Start section), which is operated at frequencies up to 50 kHz; a MCP detector is used as a Stop detector. The scientific objective of ELENA is to detect energetic neutral atoms in the range 10 eV - 5 keV, within 76° FOV, perpendicular to the S/C orbital plane. ELENA will monitor the emission of neutral atoms from the whole surface of Mercury thanks to the spacecraft motion. The major scientific objectives are the interaction between the plasma environment and the planet’s surface, the global particle loss-rate and the remote sensing of the surface properties. In particular, surface release processes are investigated by identifying particles released from the surface, via solar wind-induced ion sputtering (< 1eV - < 100 eV) as well as Hydrogen back-scattered at hundreds eV. MCP absolute detection efficiency for very low energy neutral atoms (E < 30 eV) is a crucial point for this investigation. At the MEFISTO facility of the Physical Institute of the University of Bern (CH), measurements on three different types of MCP (with and without coating) have been performed providing the detection efficiencies in the energy range 10eV - 1keV. Outcomes from such measurements are discussed here.

  15. Detection of non-classical space-time correlations with a novel type of single-photon camera.

    PubMed

    Just, Felix; Filipenko, Mykhaylo; Cavanna, Andrea; Michel, Thilo; Gleixner, Thomas; Taheri, Michael; Vallerga, John; Campbell, Michael; Tick, Timo; Anton, Gisela; Chekhova, Maria V; Leuchs, Gerd

    2014-07-14

    During the last decades, multi-pixel detectors have been developed capable of registering single photons. The newly developed hybrid photon detector camera has a remarkable property that it has not only spatial but also temporal resolution. In this work, we apply this device to the detection of non-classical light from spontaneous parametric down-conversion and use two-photon correlations for the absolute calibration of its quantum efficiency.

  16. ELENA MCP detector: absolute efficiency measurement for low energy neutral atoms

    NASA Astrophysics Data System (ADS)

    Rispoli, R.; De Angelis, E.; Colasanti, L.; Vertolli, N.; Orsini, S.; Scheer, J.; Mura, A.; Milillo, A.; Wurz, P.; Selci, S.; Di Lellis, A. M.; Leoni, R.; D'Alessandro, M.; Mattioli, F.; Cibella, S.

    2012-04-01

    MicroChannel plates (MCP) detectors are frequently used in space instrumentation for detecting a wide range of radiation and particles. In particular, the capability to detect non-thermal low energy neutral species is crucial for the sensor ELENA (Emitted Low-Energy Neutral Atoms), part of the package SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) on board the BepiColombo mission to Mercury to be launched in 2014. ELENA is a TOF sensor, based on a novel concept ultra-sonic oscillating shutter (Start section)which is operated at frequencies up to 50 kHz; a MCP detector is used as a Stop section. It is aimed to detect neutral atoms in the range 10 eV - 5 keV, within 70° FOV, perpendicular to the S/C orbital plane. ELENA will monitor the emission of neutral atoms from the whole surface of Mercury thanks to the spacecraft motion. The major scientific objectives are the interaction between the environment and the planet, the global particle loss-rate and the remote sensing of the surface properties. In particular, surface release processes are investigated by identifying particles release from the surface, via solar wind-induced ion sputtering (<1eV and >100 eV) as well as Hydrogen back-scattered at hundreds eV. MCP absolute detection efficiency for very low energy neutral atoms (E< 30eV) is a crucial point not yet investigated. At the MEFISTO facility of the Physical Institute of University of Bern (CH), measurements on three different type of MCPs coating have been performed providing the behaviors of MCP detection efficiency in the range 10eV-1keV. Outcomes from such measurements are here discussed.

  17. Traffic Vehicle Counting in Jam Flow Conditions Using Low-Cost and Energy-Efficient Wireless Magnetic Sensors.

    PubMed

    Bao, Xu; Li, Haijian; Xu, Dongwei; Jia, Limin; Ran, Bin; Rong, Jian

    2016-11-06

    The jam flow condition is one of the main traffic states in traffic flow theory and the most difficult state for sectional traffic information acquisition. Since traffic information acquisition is the basis for the application of an intelligent transportation system, research on traffic vehicle counting methods for the jam flow conditions has been worthwhile. A low-cost and energy-efficient type of multi-function wireless traffic magnetic sensor was designed and developed. Several advantages of the traffic magnetic sensor are that it is suitable for large-scale deployment and time-sustainable detection for traffic information acquisition. Based on the traffic magnetic sensor, a basic vehicle detection algorithm (DWVDA) with less computational complexity was introduced for vehicle counting in low traffic volume conditions. To improve the detection performance in jam flow conditions with a "tailgating effect" between front vehicles and rear vehicles, an improved vehicle detection algorithm (SA-DWVDA) was proposed and applied in field traffic environments. By deploying traffic magnetic sensor nodes in field traffic scenarios, two field experiments were conducted to test and verify the DWVDA and the SA-DWVDA algorithms. The experimental results have shown that both DWVDA and the SA-DWVDA algorithms yield a satisfactory performance in low traffic volume conditions (scenario I) and both of their mean absolute percent errors are less than 1% in this scenario. However, for jam flow conditions with heavy traffic volumes (scenario II), the SA-DWVDA was proven to achieve better results, and the mean absolute percent error of the SA-DWVDA is 2.54% with corresponding results of the DWVDA 7.07%. The results conclude that the proposed SA-DWVDA can implement efficient and accurate vehicle detection in jam flow conditions and can be employed in field traffic environments.

  18. Traffic Vehicle Counting in Jam Flow Conditions Using Low-Cost and Energy-Efficient Wireless Magnetic Sensors

    PubMed Central

    Bao, Xu; Li, Haijian; Xu, Dongwei; Jia, Limin; Ran, Bin; Rong, Jian

    2016-01-01

    The jam flow condition is one of the main traffic states in traffic flow theory and the most difficult state for sectional traffic information acquisition. Since traffic information acquisition is the basis for the application of an intelligent transportation system, research on traffic vehicle counting methods for the jam flow conditions has been worthwhile. A low-cost and energy-efficient type of multi-function wireless traffic magnetic sensor was designed and developed. Several advantages of the traffic magnetic sensor are that it is suitable for large-scale deployment and time-sustainable detection for traffic information acquisition. Based on the traffic magnetic sensor, a basic vehicle detection algorithm (DWVDA) with less computational complexity was introduced for vehicle counting in low traffic volume conditions. To improve the detection performance in jam flow conditions with a “tailgating effect” between front vehicles and rear vehicles, an improved vehicle detection algorithm (SA-DWVDA) was proposed and applied in field traffic environments. By deploying traffic magnetic sensor nodes in field traffic scenarios, two field experiments were conducted to test and verify the DWVDA and the SA-DWVDA algorithms. The experimental results have shown that both DWVDA and the SA-DWVDA algorithms yield a satisfactory performance in low traffic volume conditions (scenario I) and both of their mean absolute percent errors are less than 1% in this scenario. However, for jam flow conditions with heavy traffic volumes (scenario II), the SA-DWVDA was proven to achieve better results, and the mean absolute percent error of the SA-DWVDA is 2.54% with corresponding results of the DWVDA 7.07%. The results conclude that the proposed SA-DWVDA can implement efficient and accurate vehicle detection in jam flow conditions and can be employed in field traffic environments. PMID:27827974

  19. Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF.

    PubMed

    Casey, D T; Frenje, J A; Gatu Johnson, M; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Knauer, J P; Meyerhofer, D D; Sangster, T C; Bionta, R M; Bleuel, D L; Döppner, T; Glenzer, S; Hartouni, E; Hatchett, S P; Le Pape, S; Ma, T; MacKinnon, A; McKernan, M A; Moran, M; Moses, E; Park, H-S; Ralph, J; Remington, B A; Smalyuk, V; Yeamans, C B; Kline, J; Kyrala, G; Chandler, G A; Leeper, R J; Ruiz, C L; Cooper, G W; Nelson, A J; Fletcher, K; Kilkenny, J; Farrell, M; Jasion, D; Paguio, R

    2012-10-01

    A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  20. Measurements of the response function and the detection efficiency of an NE213 scintillator for neutrons between 20 and 65 MeV

    NASA Astrophysics Data System (ADS)

    Meigo, S.

    1997-02-01

    For neutrons 25, 30 and 65 MeV, the response functions and detection efficiencies of an NE213 liquid scintillator were measured. Quasi-monoenergetic neutrons produced by the 7Li(p,N 0.1) reaction were employed for the measurement and the absolute flux of incident neutrons was determined within 4% accuracy using a proton recoil telescope. Response functions and detection efficiencies calculated with the Monte Carlo codes, CECIL and SCINFUL, were compared with the measured data. It was found that response functions calculated with SCINFUL agreed better with experimental ones than those with CECIL, however, the deuteron light output used in SCINFUL was too low. The response functions calculated with a revised SCINFUL agreed with the experimental ones quite well even for the deuteron bump and peak due to the C(n,d 0) reaction. It was confirmed that the detection efficiencies calculated with the original and the revised SCINFULs agreed with the experimental data within the experimental error, while those with CECIL were about 20% higher in the energy region above 30 MeV.

  1. Comparison of the Performances of Five Primer Sets for the Detection and Quantification of Plasmodium in Anopheline Vectors by Real-Time PCR.

    PubMed

    Chaumeau, V; Andolina, C; Fustec, B; Tuikue Ndam, N; Brengues, C; Herder, S; Cerqueira, D; Chareonviriyaphap, T; Nosten, F; Corbel, V

    2016-01-01

    Quantitative real-time polymerase chain reaction (qrtPCR) has made a significant improvement for the detection of Plasmodium in anopheline vectors. A wide variety of primers has been used in different assays, mostly adapted from molecular diagnosis of malaria in human. However, such an adaptation can impact the sensitivity of the PCR. Therefore we compared the sensitivity of five primer sets with different molecular targets on blood stages, sporozoites and oocysts standards of Plasmodium falciparum (Pf) and P. vivax (Pv). Dilution series of standard DNA were used to discriminate between methods at low concentrations of parasite and to generate standard curves suitable for the absolute quantification of Plasmodium sporozoites. Our results showed that the best primers to detect blood stages were not necessarily the best ones to detect sporozoites. Absolute detection threshold of our qrtPCR assay varied between 3.6 and 360 Pv sporozoites and between 6 and 600 Pf sporozoites per mosquito according to the primer set used in the reaction mix. In this paper, we discuss the general performance of each primer set and highlight the need to use efficient detection methods for transmission studies.

  2. Comparison of the Performances of Five Primer Sets for the Detection and Quantification of Plasmodium in Anopheline Vectors by Real-Time PCR

    PubMed Central

    Chaumeau, V.; Andolina, C.; Fustec, B.; Tuikue Ndam, N.; Brengues, C.; Herder, S.; Cerqueira, D.; Chareonviriyaphap, T.; Nosten, F.; Corbel, V.

    2016-01-01

    Quantitative real-time polymerase chain reaction (qrtPCR) has made a significant improvement for the detection of Plasmodium in anopheline vectors. A wide variety of primers has been used in different assays, mostly adapted from molecular diagnosis of malaria in human. However, such an adaptation can impact the sensitivity of the PCR. Therefore we compared the sensitivity of five primer sets with different molecular targets on blood stages, sporozoites and oocysts standards of Plasmodium falciparum (Pf) and P. vivax (Pv). Dilution series of standard DNA were used to discriminate between methods at low concentrations of parasite and to generate standard curves suitable for the absolute quantification of Plasmodium sporozoites. Our results showed that the best primers to detect blood stages were not necessarily the best ones to detect sporozoites. Absolute detection threshold of our qrtPCR assay varied between 3.6 and 360 Pv sporozoites and between 6 and 600 Pf sporozoites per mosquito according to the primer set used in the reaction mix. In this paper, we discuss the general performance of each primer set and highlight the need to use efficient detection methods for transmission studies. PMID:27441839

  3. A dedicated on-line detecting system for auto air dryers

    NASA Astrophysics Data System (ADS)

    Shi, Chao-yu; Luo, Zai

    2013-10-01

    According to the correlative automobile industry standard and the requirements of manufacturer, this dedicated on-line detecting system is designed against the shortage of low degree automatic efficiency and detection precision of auto air dryer in the domestic. Fast automatic detection is achieved by combining the technology of computer control, mechatronics and pneumatics. This system can detect the speciality performance of pressure regulating valve and sealability of auto air dryer, in which online analytical processing of test data is available, at the same time, saving and inquiring data is achieved. Through some experimental analysis, it is indicated that efficient and accurate detection of the performance of auto air dryer is realized, and the test errors are less than 3%. Moreover, we carry out the type A evaluation of uncertainty in test data based on Bayesian theory, and the results show that the test uncertainties of all performance parameters are less than 0.5kPa, which can meet the requirements of operating industrial site absolutely.

  4. Design and Fabrication of Cherenkov Counters for the Detection of SNM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erickson, Anna S.; Lanza, Richard; Galaitsis, Anthony

    2011-12-13

    The need for large-size detectors for long-range active interrogation (AI) detection of SNM has generated interest in water-based detector technologies. Water Cherenkov Detectors (WCD) were selected for this research because of their transportability, scalability, and an inherent energy threshold. The detector design and analysis was completed using the Geant4 toolkit. It was demonstrated both computationally and experimentally that it is possible to use WCD to detect and characterize gamma rays. Absolute efficiency of the detector (with no energy cuts applied) was determined to be around 30% for a {sup 60}Co source.

  5. Extended performance gas Cherenkov detector for gamma-ray detection in high-energy density experiments.

    PubMed

    Herrmann, H W; Kim, Y H; Young, C S; Fatherley, V E; Lopez, F E; Oertel, J A; Malone, R M; Rubery, M S; Horsfield, C J; Stoeffl, W; Zylstra, A B; Shmayda, W T; Batha, S H

    2014-11-01

    A new Gas Cherenkov Detector (GCD) with low-energy threshold and high sensitivity, currently known as Super GCD (or GCD-3 at OMEGA), is being developed for use at the OMEGA Laser Facility and the National Ignition Facility (NIF). Super GCD is designed to be pressurized to ≤400 psi (absolute) and uses all metal seals to allow the use of fluorinated gases inside the target chamber. This will allow the gamma energy threshold to be run as low at 1.8 MeV with 400 psi (absolute) of C2F6, opening up a new portion of the gamma ray spectrum. Super GCD operating at 20 cm from TCC will be ∼400 × more efficient at detecting DT fusion gammas at 16.7 MeV than the Gamma Reaction History diagnostic at NIF (GRH-6m) when operated at their minimum thresholds.

  6. Standardization approaches in absolute quantitative proteomics with mass spectrometry.

    PubMed

    Calderón-Celis, Francisco; Encinar, Jorge Ruiz; Sanz-Medel, Alfredo

    2017-07-31

    Mass spectrometry-based approaches have enabled important breakthroughs in quantitative proteomics in the last decades. This development is reflected in the better quantitative assessment of protein levels as well as to understand post-translational modifications and protein complexes and networks. Nowadays, the focus of quantitative proteomics shifted from the relative determination of proteins (ie, differential expression between two or more cellular states) to absolute quantity determination, required for a more-thorough characterization of biological models and comprehension of the proteome dynamism, as well as for the search and validation of novel protein biomarkers. However, the physico-chemical environment of the analyte species affects strongly the ionization efficiency in most mass spectrometry (MS) types, which thereby require the use of specially designed standardization approaches to provide absolute quantifications. Most common of such approaches nowadays include (i) the use of stable isotope-labeled peptide standards, isotopologues to the target proteotypic peptides expected after tryptic digestion of the target protein; (ii) use of stable isotope-labeled protein standards to compensate for sample preparation, sample loss, and proteolysis steps; (iii) isobaric reagents, which after fragmentation in the MS/MS analysis provide a final detectable mass shift, can be used to tag both analyte and standard samples; (iv) label-free approaches in which the absolute quantitative data are not obtained through the use of any kind of labeling, but from computational normalization of the raw data and adequate standards; (v) elemental mass spectrometry-based workflows able to provide directly absolute quantification of peptides/proteins that contain an ICP-detectable element. A critical insight from the Analytical Chemistry perspective of the different standardization approaches and their combinations used so far for absolute quantitative MS-based (molecular and elemental) proteomics is provided in this review. © 2017 Wiley Periodicals, Inc.

  7. Analysis of Intrinsic Peptide Detectability via Integrated Label-Free and SRM-Based Absolute Quantitative Proteomics.

    PubMed

    Jarnuczak, Andrew F; Lee, Dave C H; Lawless, Craig; Holman, Stephen W; Eyers, Claire E; Hubbard, Simon J

    2016-09-02

    Quantitative mass spectrometry-based proteomics of complex biological samples remains challenging in part due to the variability and charge competition arising during electrospray ionization (ESI) of peptides and the subsequent transfer and detection of ions. These issues preclude direct quantification from signal intensity alone in the absence of a standard. A deeper understanding of the governing principles of peptide ionization and exploitation of the inherent ionization and detection parameters of individual peptides is thus of great value. Here, using the yeast proteome as a model system, we establish the concept of peptide F-factor as a measure of detectability, closely related to ionization efficiency. F-factor is calculated by normalizing peptide precursor ion intensity by absolute abundance of the parent protein. We investigated F-factor characteristics in different shotgun proteomics experiments, including across multiple ESI-based LC-MS platforms. We show that F-factors mirror previously observed physicochemical predictors as peptide detectability but demonstrate a nonlinear relationship between hydrophobicity and peptide detectability. Similarly, we use F-factors to show how peptide ion coelution adversely affects detectability and ionization. We suggest that F-factors have great utility for understanding peptide detectability and gas-phase ion chemistry in complex peptide mixtures, selection of surrogate peptides in targeted MS studies, and for calibration of peptide ion signal in label-free workflows. Data are available via ProteomeXchange with identifier PXD003472.

  8. Quantitative Detection of Combustion Species using Ultra-Violet Diode Lasers

    NASA Technical Reports Server (NTRS)

    Pilgrim, J. S.; Peterson, K. A.

    2001-01-01

    Southwest Sciences is developing a new microgravity combustion diagnostic based on UV diode lasers. The instrument will allow absolute concentration measurements of combustion species on a variety of microgravity combustion platforms including the Space Station. Our approach uses newly available room temperature UV diode lasers, thereby keeping the instrument compact, rugged and energy efficient. The feasibility of the technique was demonstrated by measurement of CH radicals in laboratory flames. Further progress in fabrication technology of UV diode lasers at shorter wavelengths and higher power will result in detection of transient species in the deeper UV. High sensitivity detection of combustion radicals is provided with wavelength modulation absorption spectroscopy.

  9. A LEAST ABSOLUTE SHRINKAGE AND SELECTION OPERATOR (LASSO) FOR NONLINEAR SYSTEM IDENTIFICATION

    NASA Technical Reports Server (NTRS)

    Kukreja, Sunil L.; Lofberg, Johan; Brenner, Martin J.

    2006-01-01

    Identification of parametric nonlinear models involves estimating unknown parameters and detecting its underlying structure. Structure computation is concerned with selecting a subset of parameters to give a parsimonious description of the system which may afford greater insight into the functionality of the system or a simpler controller design. In this study, a least absolute shrinkage and selection operator (LASSO) technique is investigated for computing efficient model descriptions of nonlinear systems. The LASSO minimises the residual sum of squares by the addition of a 1 penalty term on the parameter vector of the traditional 2 minimisation problem. Its use for structure detection is a natural extension of this constrained minimisation approach to pseudolinear regression problems which produces some model parameters that are exactly zero and, therefore, yields a parsimonious system description. The performance of this LASSO structure detection method was evaluated by using it to estimate the structure of a nonlinear polynomial model. Applicability of the method to more complex systems such as those encountered in aerospace applications was shown by identifying a parsimonious system description of the F/A-18 Active Aeroelastic Wing using flight test data.

  10. Thorough subcells diagnosis in a multi-junction solar cell via absolute electroluminescence-efficiency measurements

    PubMed Central

    Chen, Shaoqiang; Zhu, Lin; Yoshita, Masahiro; Mochizuki, Toshimitsu; Kim, Changsu; Akiyama, Hidefumi; Imaizumi, Mitsuru; Kanemitsu, Yoshihiko

    2015-01-01

    World-wide studies on multi-junction (tandem) solar cells have led to record-breaking improvements in conversion efficiencies year after year. To obtain detailed and proper feedback for solar-cell design and fabrication, it is necessary to establish standard methods for diagnosing subcells in fabricated tandem devices. Here, we propose a potential standard method to quantify the detailed subcell properties of multi-junction solar cells based on absolute measurements of electroluminescence (EL) external quantum efficiency in addition to the conventional solar-cell external-quantum-efficiency measurements. We demonstrate that the absolute-EL-quantum-efficiency measurements provide I–V relations of individual subcells without the need for referencing measured I–V data, which is in stark contrast to previous works. Moreover, our measurements quantify the absolute rates of junction loss, non-radiative loss, radiative loss, and luminescence coupling in the subcells, which constitute the “balance sheets” of tandem solar cells. PMID:25592484

  11. Photon-number statistics of twin beams: Self-consistent measurement, reconstruction, and properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peřina, Jan Jr.; Haderka, Ondřej; Michálek, Václav

    2014-12-04

    A method for the determination of photon-number statistics of twin beams using the joint signal-idler photocount statistics obtained by an iCCD camera is described. It also provides absolute quantum detection efficiency of the camera. Using the measured photocount statistics, quasi-distributions of integrated intensities are obtained. They attain negative values occurring in characteristic strips an a consequence of pairing of photons in twin beams.

  12. Efficient scalable solid-state neutron detector.

    PubMed

    Moses, Daniel

    2015-06-01

    We report on scalable solid-state neutron detector system that is specifically designed to yield high thermal neutron detection sensitivity. The basic detector unit in this system is made of a (6)Li foil coupled to two crystalline silicon diodes. The theoretical intrinsic efficiency of a detector-unit is 23.8% and that of detector element comprising a stack of five detector-units is 60%. Based on the measured performance of this detector-unit, the performance of a detector system comprising a planar array of detector elements, scaled to encompass effective area of 0.43 m(2), is estimated to yield the minimum absolute efficiency required of radiological portal monitors used in homeland security.

  13. High-resolution absolute position detection using a multiple grating

    NASA Astrophysics Data System (ADS)

    Schilling, Ulrich; Drabarek, Pawel; Kuehnle, Goetz; Tiziani, Hans J.

    1996-08-01

    To control electro-mechanical engines, high-resolution linear and rotary encoders are needed. Interferometric methods (grating interferometers) promise a resolution of a few nanometers, but have an ambiguity range of some microns. Incremental encoders increase the absolute measurement range by counting the signal periods starting from a defined initial point. In many applications, however, it is not possible to move to this initial point, so that absolute encoders have to be used. Absolute encoders generally have a scale with two or more tracks placed next to each other. Therefore, they use a two-dimensional grating structure to measure a one-dimensional position. We present a new method, which uses a one-dimensional structure to determine the position in one dimension. It is based on a grating with a large grating period up to some millimeters, having the same diffraction efficiency in several predefined diffraction orders (multiple grating). By combining the phase signals of the different diffraction orders, it is possible to establish the position in an absolute range of the grating period with a resolution like incremental grating interferometers. The principal functionality was demonstrated by applying the multiple grating in a heterodyne grating interferometer. The heterodyne frequency was generated by a frequency modulated laser in an unbalanced interferometer. In experimental measurements an absolute range of 8 mm was obtained while achieving a resolution of 10 nm.

  14. High-efficiency and low-background multi-segmented proportional gas counter for β-decay spectroscopy

    NASA Astrophysics Data System (ADS)

    Mukai, M.; Hirayama, Y.; Watanabe, Y. X.; Schury, P.; Jung, H. S.; Ahmed, M.; Haba, H.; Ishiyama, H.; Jeong, S. C.; Kakiguchi, Y.; Kimura, S.; Moon, J. Y.; Oyaizu, M.; Ozawa, A.; Park, J. H.; Ueno, H.; Wada, M.; Miyatake, H.

    2018-03-01

    A multi-segmented proportional gas counter (MSPGC) with high detection efficiency and low-background event rate has been developed for β-decay spectroscopy. The MSPGC consists of two cylindrically aligned layers of 16 counters (32 counters in total). Each counter has a long active length and small trapezoidal cross-section, and the total solid angle of the 32 counters is 80% of 4 π. β-rays are distinguished from the background events including cosmic-rays by analyzing the hit patterns of independent counters. The deduced intrinsic detection efficiency of each counter was almost 100%. The measured background event rate was 0.11 counts per second using the combination of veto counters for cosmic-rays and lead block shields for background γ-rays. The MSPGC was applied to measure the β-decay half-lives of 198Ir and 199mPt. The evaluated half-lives of T1/2 = 9 . 8(7) s and 12.4(7) s for 198Ir and 199mPt, respectively, were in agreement with previously reported values. The estimated absolute detection efficiency of the MSPGC from GEANT4 simulations was consistent with the evaluated efficiency from the analysis of the β- γ spectroscopy of 199Pt, saturating at approximately 60% for Qβ > 4 MeV.

  15. Automatic Seizure Detection in Rats Using Laplacian EEG and Verification with Human Seizure Signals

    PubMed Central

    Feltane, Amal; Boudreaux-Bartels, G. Faye; Besio, Walter

    2012-01-01

    Automated detection of seizures is still a challenging problem. This study presents an approach to detect seizure segments in Laplacian electroencephalography (tEEG) recorded from rats using the tripolar concentric ring electrode (TCRE) configuration. Three features, namely, median absolute deviation, approximate entropy, and maximum singular value were calculated and used as inputs into two different classifiers: support vector machines and adaptive boosting. The relative performance of the extracted features on TCRE tEEG was examined. Results are obtained with an overall accuracy between 84.81 and 96.51%. In addition to using TCRE tEEG data, the seizure detection algorithm was also applied to the recorded EEG signals from Andrzejak et al. database to show the efficiency of the proposed method for seizure detection. PMID:23073989

  16. Quaternary ammonium isobaric tag for a relative and absolute quantification of peptides.

    PubMed

    Setner, Bartosz; Stefanowicz, Piotr; Szewczuk, Zbigniew

    2018-02-01

    Isobaric labeling quantification of peptides has become a method of choice for mass spectrometry-based proteomics studies. However, despite of wide variety of commercially available isobaric tags, none of the currently available methods offers significant improvement of sensitivity of detection during MS experiment. Recently, many strategies were applied to increase the ionization efficiency of peptides involving chemical modifications introducing quaternary ammonium fixed charge. Here, we present a novel quaternary ammonium-based isobaric tag for relative and absolute quantification of peptides (QAS-iTRAQ 2-plex). Upon collisional activation, the new stable benzylic-type cationic reporter ion is liberated from the tag. Deuterium atoms were used to offset the differential masses of a reporter group. We tested the applicability of QAS-iTRAQ 2-plex reagent on a series of model peptides as well as bovine serum albumin tryptic digest. Obtained results suggest usefulness of this isobaric ionization tag for relative and absolute quantification of peptides. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Development and application of absolute quantitative detection by duplex chamber-based digital PCR of genetically modified maize events without pretreatment steps.

    PubMed

    Zhu, Pengyu; Fu, Wei; Wang, Chenguang; Du, Zhixin; Huang, Kunlun; Zhu, Shuifang; Xu, Wentao

    2016-04-15

    The possibility of the absolute quantitation of GMO events by digital PCR was recently reported. However, most absolute quantitation methods based on the digital PCR required pretreatment steps. Meanwhile, singleplex detection could not meet the demand of the absolute quantitation of GMO events that is based on the ratio of foreign fragments and reference genes. Thus, to promote the absolute quantitative detection of different GMO events by digital PCR, we developed a quantitative detection method based on duplex digital PCR without pretreatment. Moreover, we tested 7 GMO events in our study to evaluate the fitness of our method. The optimized combination of foreign and reference primers, limit of quantitation (LOQ), limit of detection (LOD) and specificity were validated. The results showed that the LOQ of our method for different GMO events was 0.5%, while the LOD is 0.1%. Additionally, we found that duplex digital PCR could achieve the detection results with lower RSD compared with singleplex digital PCR. In summary, the duplex digital PCR detection system is a simple and stable way to achieve the absolute quantitation of different GMO events. Moreover, the LOQ and LOD indicated that this method is suitable for the daily detection and quantitation of GMO events. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Mass-dependent channel electron multiplier operation. [for ion detection

    NASA Technical Reports Server (NTRS)

    Fields, S. A.; Burch, J. L.; Oran, W. A.

    1977-01-01

    The absolute counting efficiency and pulse height distributions of a continuous-channel electron multiplier used in the detection of hydrogen, argon and xenon ions are assessed. The assessment technique, which involves the post-acceleration of 8-eV ion beams to energies from 100 to 4000 eV, provides information on counting efficiency versus post-acceleration voltage characteristics over a wide range of ion mass. The charge pulse height distributions for H2 (+), A (+) and Xe (+) were measured by operating the experimental apparatus in a marginally gain-saturated mode. It was found that gain saturation occurs at lower channel multiplier operating voltages for light ions such as H2 (+) than for the heavier ions A (+) and Xe (+), suggesting that the technique may be used to discriminate between these two classes of ions in electrostatic analyzers.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ortiz-Ramírez, Pablo, E-mail: rapeitor@ug.uchile.cl; Ruiz, Andrés

    The Monte Carlo simulation of the gamma spectroscopy systems is a common practice in these days. The most popular softwares to do this are MCNP and Geant4 codes. The intrinsic spatial efficiency method is a general and absolute method to determine the absolute efficiency of a spectroscopy system for any extended sources, but this was only demonstrated experimentally for cylindrical sources. Due to the difficulty that the preparation of sources with any shape represents, the simplest way to do this is by the simulation of the spectroscopy system and the source. In this work we present the validation of themore » intrinsic spatial efficiency method for sources with different geometries and for photons with an energy of 661.65 keV. In the simulation the matrix effects (the auto-attenuation effect) are not considered, therefore these results are only preliminaries. The MC simulation is carried out using the FLUKA code and the absolute efficiency of the detector is determined using two methods: the statistical count of Full Energy Peak (FEP) area (traditional method) and the intrinsic spatial efficiency method. The obtained results show total agreement between the absolute efficiencies determined by the traditional method and the intrinsic spatial efficiency method. The relative bias is lesser than 1% in all cases.« less

  20. Absolute detection efficiency of a microchannel plate detector to X rays in the 1-100 KeV energy range

    NASA Astrophysics Data System (ADS)

    Burginyon, Gary A.; Jacoby, Barry A.; Wobser, James K.; Ernst, Richard; Ancheta, Dione S.; Tirsell, Kenneth G.

    1993-02-01

    There is little information in the literature on the performance of working micro-channel plate (MCP) detectors at high x-ray energies. We have measured the absolute efficiency of a microchannel-plate-intensified, subnanosecond, one dimensional imaging x-ray detector developed at LLNL in the 1 to 100 keV range and at 1.25 MeV. The detector consists of a gold photocathode deposited on the front surface of the MCP (optimized for Ni K(subscript (alpha) ) x rays) to convert x rays to electrons, an MCP to amplify the electrons, and a fast In:CdS phosphor that converts the electron's kinetic energy to light. The phosphor is coated on a fiber-optic faceplate to transmit the light out of the vacuum system. Electrostatic focusing electrodes compress the electron current out of the MCP in one dimension while preserving spatial resolution in the other. The calibration geometry, dictated by a recent experiment, required grazing incidence x rays (15.6 degree(s)) onto the MCP detector in order to maximize deliverable current. The experiment also used a second detector made up of 0.071 in. thick BC422 plastic scintillator material from the Bicron Corporation. We compare the absolute efficiencies of these two detectors in units of optical W/cm(superscript 2) into 4 (pi) per x ray W/cm(superscript 2) incident. At 7.47 keV and 900 volts MCP bias, the MCP detector delivers approximately 1400 times more light than the scintillator detector.

  1. Detection efficiency calculation for photons, electrons and positrons in a well detector. Part I: Analytical model

    NASA Astrophysics Data System (ADS)

    Pommé, S.

    2009-06-01

    An analytical model is presented to calculate the total detection efficiency of a well-type radiation detector for photons, electrons and positrons emitted from a radioactive source at an arbitrary position inside the well. The model is well suited to treat a typical set-up with a point source or cylindrical source and vial inside a NaI well detector, with or without lead shield surrounding it. It allows for fast absolute or relative total efficiency calibrations for a wide variety of geometrical configurations and also provides accurate input for the calculation of coincidence summing effects. Depending on its accuracy, it may even be applied in 4π-γ counting, a primary standardisation method for activity. Besides an accurate account of photon interactions, precautions are taken to simulate the special case of 511 keV annihilation quanta and to include realistic approximations for the range of (conversion) electrons and β -- and β +-particles.

  2. Quantitative Profiling of Major Neutral Lipid Classes in Human Meibum by Direct Infusion Electrospray Ionization Mass Spectrometry

    PubMed Central

    Chen, Jianzhong; Green, Kari B.; Nichols, Kelly K.

    2013-01-01

    Purpose. The purpose of this investigation was to better understand lipid composition in human meibum. Methods. Intact lipids in meibum samples were detected by direct infusion electrospray ionization mass spectrometry (ESI-MS) analysis in positive detection mode using sodium iodide (NaI) as an additive. The peak intensities of all major types of lipid species, that is, wax esters (WEs), cholesteryl esters (CEs), and diesters (DEs) were corrected for peak overlapping and isotopic distribution; an additional ionization efficiency correction was performed for WEs and CEs, which was simplified by the observation that the corresponding ionization efficiency was primarily dependent on the specific lipid class and saturation degree of the lipids while independent of the carbon chain length. A set of WE and CE standards was spiked in meibum samples for ionization efficiency determination and absolute quantitation. Results. The absolute amount (μmol/mg) for each of 51 WEs and 31 CEs in meibum samples was determined. The summed masses for 51 WEs and 31 CEs accounted for 48 ± 4% and 40 ± 2%, respectively, of the total meibum lipids. The mass percentages of saturated and unsaturated species were determined to be 75 ± 2% and 25 ± 1% for CEs and 14 ± 1% and 86 ± 1% for WEs. The profiles for two types of DEs were also obtained, which include 42 α,ω Type II DEs, and 21 ω Type I-St DEs. Conclusions. Major neutral lipid classes in meibum samples were quantitatively profiled by ESI-MS analysis with NaI additive. PMID:23847307

  3. Efficient parallel algorithms for string editing and related problems

    NASA Technical Reports Server (NTRS)

    Apostolico, Alberto; Atallah, Mikhail J.; Larmore, Lawrence; Mcfaddin, H. S.

    1988-01-01

    The string editing problem for input strings x and y consists of transforming x into y by performing a series of weighted edit operations on x of overall minimum cost. An edit operation on x can be the deletion of a symbol from x, the insertion of a symbol in x or the substitution of a symbol x with another symbol. This problem has a well known O((absolute value of x)(absolute value of y)) time sequential solution (25). The efficient Program Requirements Analysis Methods (PRAM) parallel algorithms for the string editing problem are given. If m = ((absolute value of x),(absolute value of y)) and n = max((absolute value of x),(absolute value of y)), then the CREW bound is O (log m log n) time with O (mn/log m) processors. In all algorithms, space is O (mn).

  4. Efficient Merge and Insert Operations for Binary Heaps and Trees

    NASA Technical Reports Server (NTRS)

    Kuszmaul, Christopher Lee; Woo, Alex C. (Technical Monitor)

    2000-01-01

    Binary heaps and binary search trees merge efficiently. We introduce a new amortized analysis that allows us to prove the cost of merging either binary heaps or balanced binary trees is O(l), in the amortized sense. The standard set of other operations (create, insert, delete, extract minimum, in the case of binary heaps, and balanced binary trees, as well as a search operation for balanced binary trees) remain with a cost of O(log n). For binary heaps implemented as arrays, we show a new merge algorithm that has a single operation cost for merging two heaps, a and b, of O(absolute value of a + min(log absolute value of b log log absolute value of b. log absolute value of a log absolute value of b). This is an improvement over O(absolute value of a + log absolute value of a log absolute value of b). The cost of the new merge is so low that it can be used in a new structure which we call shadow heaps. to implement the insert operation to a tunable efficiency. Shadow heaps support the insert operation for simple priority queues in an amortized time of O(f(n)) and other operations in time O((log n log log n)/f (n)), where 1 less than or equal to f (n) less than or equal to log log n. More generally, the results here show that any data structure with operations that change its size by at most one, with the exception of a merge (aka meld) operation, can efficiently amortize the cost of the merge under conditions that are true for most implementations of binary heaps and search trees.

  5. The Size Distribution of Near-Earth Objects Larger Than 10 m

    NASA Astrophysics Data System (ADS)

    Trilling, D. E.; Valdes, F.; Allen, L.; James, D.; Fuentes, C.; Herrera, D.; Axelrod, T.; Rajagopal, J.

    2017-10-01

    We analyzed data from the first year of a survey for Near-Earth Objects (NEOs) that we are carrying out with the Dark Energy Camera (DECam) on the 4 m Blanco telescope at the Cerro Tololo Inter-American Observatory. We implanted synthetic NEOs into the data stream to derive our nightly detection efficiency as a function of magnitude and rate of motion. Using these measured efficiencies and the solar system absolute magnitudes derived by the Minor Planet Center for the 1377 measurements of 235 unique NEOs detected, we directly derive, for the first time from a single observational data set, the NEO size distribution from 1 km down to 10 m. We find that there are {10}6.6 NEOs larger than 10 m. This result implies a factor of 10 fewer small NEOs than some previous results, though our derived size distribution is in good agreement with several other estimates.

  6. Study on detection geometry and detector shielding for portable PGNAA system using PHITS

    NASA Astrophysics Data System (ADS)

    Ithnin, H.; Dahing, L. N. S.; Lip, N. M.; Rashid, I. Q. Abd; Mohamad, E. J.

    2018-01-01

    Prompt gamma-ray neutron activation analysis (PGNAA) measurements require efficient detectors for gamma-ray detection. Apart from experimental studies, the Monte Carlo (MC) method has become one of the most popular tools in detector studies. The absolute efficiency for a 2 × 2 inch cylindrical Sodium Iodide (NaI) detector has been modelled using the PHITS software and compared with previous studies in literature. In the present work, PHITS code is used for optimization of portable PGNAA system using the validated NaI detector. The detection geometry is optimized by moving the detector along the sample to find the highest intensity of the prompt gamma generated from the sample. Shielding material for the validated NaI detector is also studied to find the best option for the PGNAA system setup. The result shows the optimum distance for detector is on the surface of the sample and around 15 cm from the source. The results specify that this process can be followed to determine the best setup for PGNAA system for a different sample size and detector type. It can be concluded that data from PHITS code is a strong tool not only for efficiency studies but also for optimization of PGNAA system.

  7. Development and validation of a multiplex real-time PCR method to simultaneously detect 47 targets for the identification of genetically modified organisms.

    PubMed

    Cottenet, Geoffrey; Blancpain, Carine; Sonnard, Véronique; Chuah, Poh Fong

    2013-08-01

    Considering the increase of the total cultivated land area dedicated to genetically modified organisms (GMO), the consumers' perception toward GMO and the need to comply with various local GMO legislations, efficient and accurate analytical methods are needed for their detection and identification. Considered as the gold standard for GMO analysis, the real-time polymerase chain reaction (RTi-PCR) technology was optimised to produce a high-throughput GMO screening method. Based on simultaneous 24 multiplex RTi-PCR running on a ready-to-use 384-well plate, this new procedure allows the detection and identification of 47 targets on seven samples in duplicate. To comply with GMO analytical quality requirements, a negative and a positive control were analysed in parallel. In addition, an internal positive control was also included in each reaction well for the detection of potential PCR inhibition. Tested on non-GM materials, on different GM events and on proficiency test samples, the method offered high specificity and sensitivity with an absolute limit of detection between 1 and 16 copies depending on the target. Easy to use, fast and cost efficient, this multiplex approach fits the purpose of GMO testing laboratories.

  8. Radiometric calibration of optical microscopy and microspectroscopy apparata over a broad spectral range using a special thin-film luminescence standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valenta, J., E-mail: jan.valenta@mff.cuni.cz; Greben, M.

    2015-04-15

    Application capabilities of optical microscopes and microspectroscopes can be considerably enhanced by a proper calibration of their spectral sensitivity. We propose and demonstrate a method of relative and absolute calibration of a microspectroscope over an extraordinary broad spectral range covered by two (parallel) detection branches in visible and near-infrared spectral regions. The key point of the absolute calibration of a relative spectral sensitivity is application of the standard sample formed by a thin layer of Si nanocrystals with stable and efficient photoluminescence. The spectral PL quantum yield and the PL spatial distribution of the standard sample must be characterized bymore » separate experiments. The absolutely calibrated microspectroscope enables to characterize spectral photon emittance of a studied object or even its luminescence quantum yield (QY) if additional knowledge about spatial distribution of emission and about excitance is available. Capabilities of the calibrated microspectroscope are demonstrated by measuring external QY of electroluminescence from a standard poly-Si solar-cell and of photoluminescence of Er-doped Si nanocrystals.« less

  9. Absolute Total Photoionization Cross Section of C60 in the Range of 25-120 eV: Revisited

    NASA Astrophysics Data System (ADS)

    Kafle, Bhim P.; Katayanagi, Hideki; Prodhan, Md. Serajul I.; Yagi, Hajime; Huang, Chaoqun; Mitsuke, Koichiro

    2008-01-01

    The absolute total photoionization cross section σabs,I of gaseous C60 is measured in the photon energy hν range from 25 to 120 eV by photoionization mass spectrometry with synchrotron radiation. The absolute detection efficiencies of photoions in different charge states are evaluated. The present σabs,I curve is combined with the photoabsorption cross section curves of C60 at hν=3.5--26 eV in the literature, after appropriate alterations of the vapor pressure are taken into account. The oscillator strengths are computed from the composite curve to be 178.5 and 230.5 for the hν ranges from 3.5 to 40.8 eV and from 3.5 to 119 eV, respectively. These oscillator strengths agree well with those expected from the Thomas-Kuhn-Reiche sum rule and 60 times the photoabsorption cross section of a carbon atom. Moreover, the present σabs,I curve behaves similarly to the relative photoionization cross section curve reported by Reinköster et al.

  10. Metabolomics for the Authentication of Natural Extracts Used in Flavors and Fragrances: the Case Study of Violet Leaf Absolutes from Viola odorata.

    PubMed

    Saint-Lary, Laure; Roy, Céline; Paris, Jean-Philippe; Martin, Jean-François; Thomas, Olivier P; Fernandez, Xavier

    2016-06-01

    Natural extracts used in fine fragrances (alcoholic perfumes) are rare and precious. As such, they represent an interesting target for fraudulent practices called adulterations. Absolutes, important materials used in the creation of perfumes, are obtained by organic solvent extraction of raw plant materials. Because the nonvolatile part of these natural extracts is not normalized and scarcely reported, highlighting potential adulterations present in this fraction appears highly challenging. For the first time, we investigated the use of nontargeted UHPLC-ToFMS metabolomics for this purpose, considering Viola odorata l., a plant largely used in the perfume industry, as a model. Significant differences in the metabolic fingerprints of the violet leaf absolutes were evidenced according to geographical locations, and/or adulterations. Additionally, markers of the geographical origin were detected through their molecular weight/most probable molecular formula and retention time, while adulterations were statistically validated. In this study, we thus clearly demonstrated the efficiency of UHPLC-ToFMS-based metabolomics in accelerating both the identification of the origin of raw materials as well as the search for potential adulterations in absolutes, natural products of high added value. © 2016 Verlag Helvetica Chimica Acta AG, Zürich.

  11. The future scientific CCD

    NASA Technical Reports Server (NTRS)

    Janesick, J. R.; Elliott, T.; Collins, S.; Marsh, H.; Blouke, M. M.

    1984-01-01

    Since the first introduction of charge-coupled devices (CCDs) in 1970, CCDs have been considered for applications related to memories, logic circuits, and the detection of visible radiation. It is pointed out, however, that the mass market orientation of CCD development has left largely untapped the enormous potential of these devices for advanced scientific instrumentation. The present paper has, therefore, the objective to introduce the CCD characteristics to the scientific community, taking into account prospects for further improvement. Attention is given to evaluation criteria, a summary of current CCDs, CCD performance characteristics, absolute calibration tools, quantum efficiency, aspects of charge collection, charge transfer efficiency, read noise, and predictions regarding the characteristics of the next generation of silicon scientific CCD imagers.

  12. Structure Detection of Nonlinear Aeroelastic Systems with Application to Aeroelastic Flight Test Data. Part 2

    NASA Technical Reports Server (NTRS)

    Kukreja, Sunil L.; Brenner, martin J.

    2006-01-01

    This viewgraph presentation reviews the 1. Motivation for the study 2. Nonlinear Model Form 3. Structure Detection 4. Least Absolute Shrinkage and Selection Operator (LASSO) 5. Objectives 6. Results 7. Assess LASSO as a Structure Detection Tool: Simulated Nonlinear Models 8. Applicability to Complex Systems: F/A-18 Active Aeroelastic Wing Flight Test Data. The authors conclude that 1. this is a novel approach for detecting the structure of highly over-parameterised nonlinear models in situations where other methods may be inadequate 2. that it is a practical significance in the analysis of aircraft dynamics during envelope expansion and could lead to more efficient control strategies and 3. this could allow greater insight into the functionality of various systems dynamics, by providing a quantitative model which is easily interpretable

  13. Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McIntyre, Justin I.; Cooper, Matthew W.; Carman, April J.

    Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute sourcemore » strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.« less

  14. Analysis of sewage sludge using an experimental prompt gamma neutron activation analysis (pgnaa) set-up with an am-be source

    NASA Astrophysics Data System (ADS)

    Idiri, Z.; Redjem, F.; Beloudah, N.

    2016-09-01

    An experimental PGNAA set-up using a 1 Ci Am-Be source has been developed and used for analysis of bulk sewage sludge samples issued from a wastewater treatment plant situated in an industrial area of Algiers. The sample dimensions were optimized using thermal neutron flux calculations carried out with the MCNP5 Monte Carlo Code. A methodology is then proposed to perform quantitative analysis using the absolute method. For this, average thermal neutron flux inside the sludge samples is deduced using average thermal neutron flux in reference water samples and thermal flux measurements with the aid of a 3He neutron detector. The average absolute gamma detection efficiency is determined using the prompt gammas emitted by chlorine dissolved in a water sample. The gamma detection efficiency is normalized for sludge samples using gamma attenuation factors calculated with the MCNP5 code for water and sludge. Wet and dehydrated sludge samples were analyzed. Nutritive elements (Ca, N, P, K) and heavy metals elements like Cr and Mn were determined. For some elements, the PGNAA values were compared to those obtained using Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma (ICP) methods. Good agreement is observed between the different values. Heavy element concentrations are very high compared to normal values; this is related to the fact that the wastewater treatment plant is treating not only domestic but also industrial wastewater that is probably rejected by industries without removal of pollutant elements. The detection limits for almost all elements of interest are sufficiently low for the method to be well suited for such analysis.

  15. A novel specific duplex real-time RT-PCR method for absolute quantitation of Grapevine Pinot gris virus in plant material and single mites.

    PubMed

    Morán, Félix; Olmos, Antonio; Lotos, Leonidas; Predajňa, Lukáš; Katis, Nikolaos; Glasa, Miroslav; Maliogka, Varvara; Ruiz-García, Ana B

    2018-01-01

    Grapevine Pinot gris virus (GPGV) is a widely distributed grapevine pathogen that has been associated to the grapevine leaf mottling and deformation disease. With the aim of better understanding the disease epidemiology and providing efficient control strategies a specific and quantitative duplex TaqMan real-time RT-PCR assay has been developed. This method has allowed reliable quantitation of the GPGV titer ranging from 30 up to 3 x 108 transcript copies, with a detection limit of 70 viral copies in plant material. The assay targets a grapevine internal control that reduces the occurrence of false negative results, thus increasing the diagnostic sensitivity of the technique. Viral isolates both associated and non-associated to symptoms from Greece, Slovakia and Spain have been successfully detected. The method has also been applied to the absolute quantitation of GPGV in its putative transmission vector Colomerus vitis. Moreover, the viral titer present in single mites has been determined. In addition, in the current study a new polymorphism in the GPGV genome responsible for a shorter movement protein has been found. A phylogenetic study based on this genomic region has shown a high variability among Spanish isolates and points to a different evolutionary origin of this new polymorphism. The methodology here developed opens new possibilities for basic and epidemiological studies as well as for the establishment of efficient control strategies.

  16. Electron Density and Temperature Measurements At Mercury Using Thermal Noise Spectroscopy

    NASA Astrophysics Data System (ADS)

    Moncuquet, M.; Bougeret, J.-L.; Hellinger, P.; Issautier, K.; Maksimovic, M.; Manning, R.; Meyer-Vernet, N.; Travnicek, P.; Zarka, P.

    With an innovative procedure, we have constructed a model of the de-biased orbital and magnitude distribution of Near Earth Objects (NEOs), up to absolute magnitude H=22. This model accounts for 4 main sources of Near Earth Objects in the asteroid belt and for extinct Jupiter Family Comets (JFCs). It fits well the orbital-magnitude distribution of the NEOs detected by the Spacewatch Survey, once the observational biases are properly taken into account. The model predicts the existence of 960 NEOs with absolute magnitude H<18 and semimajor axis a<7.8 AU. of these, 58 bodies should be Aten (NEOs with a<1 AU), 590 should be Apollo (NEOs with a>1 AU and perihelion distance q<1 AU) and 310 should be Amor (NEOs with 11km is 834, which, compared to the total number of NEOs with H<18 (963), shows that the usually assumed conversion H=18 <=> D=1km is slightly pessimistic, on average (the exact correspondence would be H=17.82). In a size limited sample, our model predicts that the de-biased ratio between dark and bright (albedo smaller or larger than 0.089) NEOs is 0.8 (I.E., 56% of the NEO with a < 7.4 AU have dark albedos). Moreover, combining our orbital distribution model with the new albedo distribution model, and assuming that the density of bright and dark bodies is 2.7 and 1.3 g/cm3, respectively, we estimate that the Earth should undergo a 1000 megatons collision every 64,000 years. Based on our model, we have computed the expected NEO distribution in the sky to- gether with their apparent magnitudes and rates of motion. This is the basis to simulate the efficiency of the various survey strategies. To understand the detection efficiency of various survey strategies, we have first simulated ``perfect surveys" as benchmarks. These are 100% efficient, all-sky, every night survey, subject only to the constraints of 1 detection above a specified air mass and when the Sun is below the horizon. We have computed that such a survey must have a limiting magnitude of about V=21 to reach 90% detection of NEOs with H<18 within ten years. Slightly more realistic surveys, limited by latitude, the galaxy, minimum rates of NEO motion, etc, require progres- sively fainter limiting magnitude to reach the 90% completion level. A survey with the sky-coverage of LINEAR could detect 90% of the NEOs with H<18 only if its limiting magnitude is 24 (the current 50% efficiency magnitude of LINEAR is around 18.5). Our simulations suggest that there may be little need for distributing survey telescopes in longitude and latitude as long as there is sufficient sky coverage from a telescope or network of telescopes which may be geographically close. Conversely, a space based survey, especially from a satellite orbit much interior to Earth, offers a tremendous advantage over their terrestrial planted brethren. For instance, a perfect survey based at Mercury with limiting magnitude V=18 would discover 90% of the NEOs with H<18 in less than 4 years. 2

  17. Improved determination of the neutron lifetime.

    PubMed

    Yue, A T; Dewey, M S; Gilliam, D M; Greene, G L; Laptev, A B; Nico, J S; Snow, W M; Wietfeldt, F E

    2013-11-27

    The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of τ(n)=(886.3±1.2[stat]±3.2[syst]) s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. In the current work, we measure the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally absorbing neutron detector. This direct approach does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but is measured with a precision of 0.057%, which represents a fivefold improvement in the uncertainty. We verify the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is τ(n)=(887.7±1.2[stat]±1.9[syst]) s.

  18. Measured and simulated performance of Compton-suppressed TIGRESS HPGe clover detectors

    NASA Astrophysics Data System (ADS)

    Schumaker, M. A.; Hackman, G.; Pearson, C. J.; Svensson, C. E.; Andreoiu, C.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Boston, A. J.; Chakrawarthy, R. S.; Churchman, R.; Drake, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hyland, B.; Jones, B.; Maharaj, R.; Morton, A. C.; Phillips, A. A.; Sarazin, F.; Scraggs, H. C.; Smith, M. B.; Valiente-Dobón, J. J.; Waddington, J. C.; Watters, L. M.

    2007-01-01

    Tests of the performance of a 32-fold segmented HPGe clover detector coupled to a 20-fold segmented Compton-suppression shield, which form a prototype element of the TRIUMF-ISAC Gamma-Ray Escape-Suppressed Spectrometer (TIGRESS), have been made. Peak-to-total ratios and relative efficiencies have been measured for a variety of γ-ray energies. These measurements were used to validate a GEANT4 simulation of the TIGRESS detectors, which was then used to create a simulation of the full 12-detector array. Predictions of the expected performance of TIGRESS are presented. These predictions indicate that TIGRESS will be capable, for single 1 MeV γ rays, of absolute detection efficiencies of 17% and 9.4%, and peak-to-total ratios of 54% and 61% for the "high-efficiency" and "optimized peak-to-total" configurations of the array, respectively.

  19. Dispersion compensation of fiber optic communication system with direct detection using artificial neural networks (ANNs)

    NASA Astrophysics Data System (ADS)

    Maghrabi, Mahmoud M. T.; Kumar, Shiva; Bakr, Mohamed H.

    2018-02-01

    This work introduces a powerful digital nonlinear feed-forward equalizer (NFFE), exploiting multilayer artificial neural network (ANN). It mitigates impairments of optical communication systems arising due to the nonlinearity introduced by direct photo-detection. In a direct detection system, the detection process is nonlinear due to the fact that the photo-current is proportional to the absolute square of the electric field intensity. The proposed equalizer provides the most efficient computational cost with high equalization performance. Its performance is comparable to the benchmark compensation performance achieved by maximum-likelihood sequence estimator. The equalizer trains an ANN to act as a nonlinear filter whose impulse response removes the intersymbol interference (ISI) distortions of the optical channel. Owing to the proposed extensive training of the equalizer, it achieves the ultimate performance limit of any feed-forward equalizer (FFE). The performance and efficiency of the equalizer is investigated by applying it to various practical short-reach fiber optic communication system scenarios. These scenarios are extracted from practical metro/media access networks and data center applications. The obtained results show that the ANN-NFFE compensates for the received BER degradation and significantly increases the tolerance to the chromatic dispersion distortion.

  20. Observer efficiency in free-localization tasks with correlated noise.

    PubMed

    Abbey, Craig K; Eckstein, Miguel P

    2014-01-01

    The efficiency of visual tasks involving localization has traditionally been evaluated using forced choice experiments that capitalize on independence across locations to simplify the performance of the ideal observer. However, developments in ideal observer analysis have shown how an ideal observer can be defined for free-localization tasks, where a target can appear anywhere in a defined search region and subjects respond by localizing the target. Since these tasks are representative of many real-world search tasks, it is of interest to evaluate the efficiency of observer performance in them. The central question of this work is whether humans are able to effectively use the information in a free-localization task relative to a similar task where target location is fixed. We use a yes-no detection task at a cued location as the reference for this comparison. Each of the tasks is evaluated using a Gaussian target profile embedded in four different Gaussian noise backgrounds having power-law noise power spectra with exponents ranging from 0 to 3. The free localization task had a square 6.7° search region. We report on two follow-up studies investigating efficiency in a detect-and-localize task, and the effect of processing the white-noise backgrounds. In the fixed-location detection task, we find average observer efficiency ranges from 35 to 59% for the different noise backgrounds. Observer efficiency improves dramatically in the tasks involving localization, ranging from 63 to 82% in the forced localization tasks and from 78 to 92% in the detect-and- localize tasks. Performance in white noise, the lowest efficiency condition, was improved by filtering to give them a power-law exponent of 2. Classification images, used to examine spatial frequency weights for the tasks, show better tuning to ideal weights in the free-localization tasks. The high absolute levels of efficiency suggest that observers are well-adapted to free-localization tasks.

  1. Observer efficiency in free-localization tasks with correlated noise

    PubMed Central

    Abbey, Craig K.; Eckstein, Miguel P.

    2014-01-01

    The efficiency of visual tasks involving localization has traditionally been evaluated using forced choice experiments that capitalize on independence across locations to simplify the performance of the ideal observer. However, developments in ideal observer analysis have shown how an ideal observer can be defined for free-localization tasks, where a target can appear anywhere in a defined search region and subjects respond by localizing the target. Since these tasks are representative of many real-world search tasks, it is of interest to evaluate the efficiency of observer performance in them. The central question of this work is whether humans are able to effectively use the information in a free-localization task relative to a similar task where target location is fixed. We use a yes-no detection task at a cued location as the reference for this comparison. Each of the tasks is evaluated using a Gaussian target profile embedded in four different Gaussian noise backgrounds having power-law noise power spectra with exponents ranging from 0 to 3. The free localization task had a square 6.7° search region. We report on two follow-up studies investigating efficiency in a detect-and-localize task, and the effect of processing the white-noise backgrounds. In the fixed-location detection task, we find average observer efficiency ranges from 35 to 59% for the different noise backgrounds. Observer efficiency improves dramatically in the tasks involving localization, ranging from 63 to 82% in the forced localization tasks and from 78 to 92% in the detect-and- localize tasks. Performance in white noise, the lowest efficiency condition, was improved by filtering to give them a power-law exponent of 2. Classification images, used to examine spatial frequency weights for the tasks, show better tuning to ideal weights in the free-localization tasks. The high absolute levels of efficiency suggest that observers are well-adapted to free-localization tasks. PMID:24817854

  2. A universal TaqMan-based RT-PCR protocol for cost-efficient detection of small noncoding RNA.

    PubMed

    Jung, Ulrike; Jiang, Xiaoou; Kaufmann, Stefan H E; Patzel, Volker

    2013-12-01

    Several methods for the detection of RNA have been developed over time. For small RNA detection, a stem-loop reverse primer-based protocol relying on TaqMan RT-PCR has been described. This protocol requires an individual specific TaqMan probe for each target RNA and, hence, is highly cost-intensive for experiments with small sample sizes or large numbers of different samples. We describe a universal TaqMan-based probe protocol which can be used to detect any target sequence and demonstrate its applicability for the detection of endogenous as well as artificial eukaryotic and bacterial small RNAs. While the specific and the universal probe-based protocol showed the same sensitivity, the absolute sensitivity of detection was found to be more than 100-fold lower for both than previously reported. In subsequent experiments, we found previously unknown limitations intrinsic to the method affecting its feasibility in determination of mature template RISC incorporation as well as in multiplexing. Both protocols were equally specific in discriminating between correct and incorrect small RNA targets or between mature miRNA and its unprocessed RNA precursor, indicating the stem-loop RT-primer, but not the TaqMan probe, triggers target specificity. The presented universal TaqMan-based RT-PCR protocol represents a cost-efficient method for the detection of small RNAs.

  3. Development of a duplex droplet digital PCR assay for absolute quantitative detection of "Candidatus Liberibacter asiaticus".

    PubMed

    Selvaraj, Vijayanandraj; Maheshwari, Yogita; Hajeri, Subhas; Chen, Jianchi; McCollum, Thomas Greg; Yokomi, Raymond

    2018-01-01

    Huanglongbing (HLB, citrus greening) is a devastating citrus disease affecting citrus production worldwide. It is associated with the bacterium "Candidatus Liberibacter asiaticus" (CLas) and is vectored by the Asian citrus psyllid (ACP). Currently, diagnosis of CLas in regulatory samples is based on real-time quantitative polymerase chain reaction (qPCR) using 16S rRNA gene specific primers/probe. The detection of CLas using qPCR is challenging due to low pathogen titer and uneven distribution in infected plants and exacerbated by sampling issues and presence of inhibitors. This study evaluated a duplex droplet digital polymerase chain reaction (ddPCR) using multi-copy gene targets, 16S and RNR, to simultaneously detect CLas DNA targets in the same sample for unambiguous detection of the HLB pathogen in DNA extracts from citrus leaves and ACP. Standard curve analyses on tenfold dilution series with plasmid, citrus leaf and ACP DNA showed that both ddPCR and qPCR exhibited good linearity and efficiency in the duplex assay. CLas-infected low titer samples were used to validate the duplex ddPCR and qPCR performance and demonstrated that detection rate is higher when both 16S and RNR primers were used in duplex assay. However, the receiver operating characteristic analysis indicated that area under the curve for RNR primer was significantly broader, compared to 16S primers for CLas detection at low target titer. The absolute quantification of CLas at variable titers was reproducible and repeatable for both primer sets and the ddPCR showed higher resilience to PCR inhibitors with citrus leaf and ACP extracts. Hence, the resultant duplex ddPCR assay resulted in a significantly improved detection platform for diagnosis of CLas in samples with low pathogen titer.

  4. Development of a duplex droplet digital PCR assay for absolute quantitative detection of "Candidatus Liberibacter asiaticus"

    PubMed Central

    Hajeri, Subhas; Chen, Jianchi; McCollum, Thomas Greg

    2018-01-01

    Huanglongbing (HLB, citrus greening) is a devastating citrus disease affecting citrus production worldwide. It is associated with the bacterium “Candidatus Liberibacter asiaticus” (CLas) and is vectored by the Asian citrus psyllid (ACP). Currently, diagnosis of CLas in regulatory samples is based on real-time quantitative polymerase chain reaction (qPCR) using 16S rRNA gene specific primers/probe. The detection of CLas using qPCR is challenging due to low pathogen titer and uneven distribution in infected plants and exacerbated by sampling issues and presence of inhibitors. This study evaluated a duplex droplet digital polymerase chain reaction (ddPCR) using multi-copy gene targets, 16S and RNR, to simultaneously detect CLas DNA targets in the same sample for unambiguous detection of the HLB pathogen in DNA extracts from citrus leaves and ACP. Standard curve analyses on tenfold dilution series with plasmid, citrus leaf and ACP DNA showed that both ddPCR and qPCR exhibited good linearity and efficiency in the duplex assay. CLas-infected low titer samples were used to validate the duplex ddPCR and qPCR performance and demonstrated that detection rate is higher when both 16S and RNR primers were used in duplex assay. However, the receiver operating characteristic analysis indicated that area under the curve for RNR primer was significantly broader, compared to 16S primers for CLas detection at low target titer. The absolute quantification of CLas at variable titers was reproducible and repeatable for both primer sets and the ddPCR showed higher resilience to PCR inhibitors with citrus leaf and ACP extracts. Hence, the resultant duplex ddPCR assay resulted in a significantly improved detection platform for diagnosis of CLas in samples with low pathogen titer. PMID:29772016

  5. Relative radiometric calibration for multispectral remote sensing imagery

    NASA Astrophysics Data System (ADS)

    Ren, Hsuan

    2006-10-01

    Our environment has been changed continuously by nature causes or human activities. In order to identify what has been changed during certain time period, we need to spend enormous resources to collect all kinds of data and analyze them. With remote sensing images, change detection has become one efficient and inexpensive technique. It has wide applications including disaster management, agriculture analysis, environmental monitoring and military reconnaissance. To detect the changes between two remote sensing images collected at different time, radiometric calibration is one of the most important processes. Under the different weather and atmosphere conditions, even the same material might be resulting distinct radiance spectrum in two images. In this case, they will be misclassified as changes and false alarm rate will also increase. To achieve absolute calibration, i.e., to convert the radiance to reflectance spectrum, the information about the atmosphere condition or ground reference materials with known reflectance spectrum is needed but rarely available. In this paper, we present relative radiometric calibration methods which transform image pair into similar atmospheric effect instead of remove it in absolutely calibration, so that the information of atmosphere condition is not required. A SPOT image pair will be used for experiment to demonstrate the performance.

  6. Enhanced explosive sensing based on bis(methyltetraphenyl)silole nanoaggregate

    NASA Astrophysics Data System (ADS)

    Shin, Bomina; Sohn, Honglae

    2018-01-01

    New photoluminescent bis(methyltetraphenyl)silole nanoaggregates for the detection of trinitrotoluene (TNT) were developed by using aggregation-induced emission property. Bis(methyltetraphenyl)silole nanoaggregates exhibited that photoluminescence (PL) intensity was increased when the water fraction was increased to 90% by volume. Relative PL efficiency of bis(methyltetraphenyl)silole nanoaggregates was exponentially increased to the percent of water fraction and particle diameter was dependent on solvent composition. Particle size of bis(methyltetraphenyl)silole nanoaggregates was tuned by controlling the water fraction by volume. Absolute quantum yield of bis(methyltetraphenyl)silole nanoaggregates in 90% water volume fraction were 32.4%, which increases by about 40 times. Detection of TNT was achieved from the quenching PL measurement of bis(methyltetraphenyl)silole nanoaggregates by adding the TNT. A linear Stern-Volmer relationship was observed for the detection of TNT.

  7. Adaptation of a military FTS to civilian air toxics measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engel, J.R.; Dorval, R.K.

    1994-12-31

    In many ways, the military problem of chemical agent detection is similar to the civilian problem of toxic and related air pollutants detection. A recent program to design a next generation Fourier transform spectrometer (FTS) based chemical agent detection system has been funded by the US Army. This program has resulted in an FTS system that has a number of characteristics that make it suitable for applications to the civilian measurement problem. Low power, low weight, and small size lead to low installation, operating and maintenance costs. Innovative use of diode lasers in place of HeNe reference sources leads tomore » long lifetimes and high reliability. Absolute scan position servos allow for highly efficient offset scanning. This paper will relate the performance of this system to present air monitoring requirements.« less

  8. Sort entropy-based for the analysis of EEG during anesthesia

    NASA Astrophysics Data System (ADS)

    Ma, Liang; Huang, Wei-Zhi

    2010-08-01

    The monitoring of anesthetic depth is an absolutely necessary procedure in the process of surgical operation. To judge and control the depth of anesthesia has become a clinical issue which should be resolved urgently. EEG collected wiil be processed by sort entrop in this paper. Signal response of the surface of the cerebral cortex is determined for different stages of patients in the course of anesthesia. EEG is simulated and analyzed through the fast algorithm of sort entropy. The results show that discipline of phasic changes for EEG is very detected accurately,and it has better noise immunity in detecting the EEG anaesthetized than approximate entropy. In conclusion,the computing of Sort entropy algorithm requires shorter time. It has high efficiency and strong anti-interference.

  9. A loophole-free Bell's inequality experiment

    NASA Astrophysics Data System (ADS)

    Kwiat, Paul G.; Steinberg, Aephraim M.; Chiao, Raymond Y.; Eberhard, Philippe H.

    1994-05-01

    The proof of Nature's nonlocality through Bell-type experiments is a topic of longstanding interest. Nevertheless, no experiments performed thus far have avoided the so-called 'detection loophole,' arising from low detector efficiencies and angular-correlation difficulties. In fact, most, if not all, of the systems employed to date can never close this loophole, even with perfect detectors. In addition, another loophole involving the non-rapid, non-random switching of various parameter settings exists in all past experiments. We discuss a proposal for a potentially loophole-free Bell's inequality experiment. The source of the EPR-correlated pairs consists of two simultaneously-pumped type-2 phase-matched nonlinear crystals and a polarizing beam splitter. The feasibility of such a scheme with current detector technology seems high, and will be discussed. We also present a single-crystal version, motivated by other work presented at this conference. In a separate experiment, we have measured the absolute detection efficiency and time response of four single-photon detectors. The highest observed efficiencies were 70.7 plus or minus 1.9 percent (at 633 nm, with a device from Rockwell International) and 76.4 plus or minus 2.3 percent (at 702 nm, with an EG&G counting module). Possible efficiencies as high as 90 percent were implied. The EG&G devices displayed sub-nanosecond time resolution.

  10. A loophole-free Bell's inequality experiment

    NASA Technical Reports Server (NTRS)

    Kwiat, Paul G.; Steinberg, Aephraim M.; Chiao, Raymond Y.; Eberhard, Philippe H.

    1994-01-01

    The proof of Nature's nonlocality through Bell-type experiments is a topic of longstanding interest. Nevertheless, no experiments performed thus far have avoided the so-called 'detection loophole,' arising from low detector efficiencies and angular-correlation difficulties. In fact, most, if not all, of the systems employed to date can never close this loophole, even with perfect detectors. In addition, another loophole involving the non-rapid, non-random switching of various parameter settings exists in all past experiments. We discuss a proposal for a potentially loophole-free Bell's inequality experiment. The source of the EPR-correlated pairs consists of two simultaneously-pumped type-2 phase-matched nonlinear crystals and a polarizing beam splitter. The feasibility of such a scheme with current detector technology seems high, and will be discussed. We also present a single-crystal version, motivated by other work presented at this conference. In a separate experiment, we have measured the absolute detection efficiency and time response of four single-photon detectors. The highest observed efficiencies were 70.7 plus or minus 1.9 percent (at 633 nm, with a device from Rockwell International) and 76.4 plus or minus 2.3 percent (at 702 nm, with an EG&G counting module). Possible efficiencies as high as 90 percent were implied. The EG&G devices displayed sub-nanosecond time resolution.

  11. Factors concerned in the efficient steam sterilization of surgical dressings

    PubMed Central

    Fallon, R. J.

    1961-01-01

    Some of the factors affecting the efficient steam sterilization of dressings have been examined. A jacketed sterilizer will process a load more quickly than a sterilizer without a jacket. The level of fore-vacuum is critical and must reach an absolute pressure of 20 mm. Hg (29·2 in.Hg vacuum) or less. This will overcome all conditions of overpacking studied. The level of after-vacuum should be 100 mm. Hg absolute or less, preferably near 50 mm. Hg absolute. Overpacking cannot be defined in terms of weight of a fabric per unit volume of container but occurs when a load is compressed in its container. PMID:13891475

  12. Improved Determination of the Neutron Lifetime

    NASA Astrophysics Data System (ADS)

    Yue, A.

    2013-10-01

    The most precise determination of the neutron lifetime using the beam method reported a result of τn = (886 . 3 +/- 3 . 4) s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was determined with a monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. We have used a second, totally-absorbing neutron detector to directly measure the detection efficiency of the monitor on a monochromatic neutron beam of precisely known wavelength. This method does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The monitor detection efficiency was measured to an uncertainty of 0.06%, which represents a five-fold improvement in uncertainty. We have verified the temporal stability of the monitor with ancillary measurements, and the measured neutron monitor efficiency has been used to improve the fluence determination in the past lifetime experiment. An updated neutron lifetime based on the improved fluence determination will be presented. Work done in collaboration with M. Dewey, D. Gilliam, J. Nico, National Institute of Standards and Technology; G. Greene, University of Tennessee / Oak Ridge National Laboratory; A. Laptev, Los Alamos National Laboratory; W. Snow, Indiana University; and F. Wietfeldt, Tulane University.

  13. Nanotechnology for the detection and kill of circulating tumor cells

    NASA Astrophysics Data System (ADS)

    Gao, Yang; Yuan, Zhou

    2014-09-01

    Circulating tumor cells (CTCs) represent a surrogate biomarker of hematogenous metastases and thus could be considered as a `liquid biopsy' which reveals metastasis in action. But it is absolutely a challenge to detect CTCs due to their extreme rarity. At present, the most common principle is to take advantage of the epithelial surface markers of CTCs which attach to a specific antibody. Antibody-magnetic nanobeads combine with the epithelial surface markers, and then the compound is processed by washing, separation, and detection. However, a proportion of CTC antigen expressions are down-regulated or lost in the process of epithelial-mesenchymal transition (EMT), and thus, this part of CTCs cannot be detected by classical detection methods such as CellSearch. To resolve this problem, some multiple-marker CTC detections have been developed rapidly. Additionally, nanotechnology is a promising approach to kill CTCs with high efficiency. Implantable nanotubes coated with apoptosis-promoting molecules improve the disease-free survival and overall survival. The review introduces some novel CTC detection techniques and therapeutic methods by virtue of nanotechnology to provide a better knowledge of the progress about CTC study.

  14. Key parameters design of an aerial target detection system on a space-based platform

    NASA Astrophysics Data System (ADS)

    Zhu, Hanlu; Li, Yejin; Hu, Tingliang; Rao, Peng

    2018-02-01

    To ensure flight safety of an aerial aircraft and avoid recurrence of aircraft collisions, a method of multi-information fusion is proposed to design the key parameter to realize aircraft target detection on a space-based platform. The key parameters of a detection wave band and spatial resolution using the target-background absolute contrast, target-background relative contrast, and signal-to-clutter ratio were determined. This study also presented the signal-to-interference ratio for analyzing system performance. Key parameters are obtained through the simulation of a specific aircraft. And the simulation results show that the boundary ground sampling distance is 30 and 35 m in the mid- wavelength infrared (MWIR) and long-wavelength infrared (LWIR) bands for most aircraft detection, and the most reasonable detection wavebands is 3.4 to 4.2 μm and 4.35 to 4.5 μm in the MWIR bands, and 9.2 to 9.8 μm in the LWIR bands. We also found that the direction of detection has a great impact on the detection efficiency, especially in MWIR bands.

  15. Extremely high absolute internal quantum efficiency of photoluminescence in co-doped GaN:Zn,Si

    NASA Astrophysics Data System (ADS)

    Reshchikov, M. A.; Willyard, A. G.; Behrends, A.; Bakin, A.; Waag, A.

    2011-10-01

    We report on the fabrication of GaN co-doped with silicon and zinc by metalorganic vapor phase epitaxy and a detailed study of photoluminescence in this material. We observe an exceptionally high absolute internal quantum efficiency of blue photoluminescence in GaN:Zn,Si. The value of 0.93±0.04 has been obtained from several approaches based on rate equations.

  16. Detection limits of organic compounds achievable with intense, short-pulse lasers.

    PubMed

    Miles, Jordan; De Camillis, Simone; Alexander, Grace; Hamilton, Kathryn; Kelly, Thomas J; Costello, John T; Zepf, Matthew; Williams, Ian D; Greenwood, Jason B

    2015-06-21

    Many organic molecules have strong absorption bands which can be accessed by ultraviolet short pulse lasers to produce efficient ionization. This resonant multiphoton ionization scheme has already been exploited as an ionization source in time-of-flight mass spectrometers used for environmental trace analysis. In the present work we quantify the ultimate potential of this technique by measuring absolute ion yields produced from the interaction of 267 nm femtosecond laser pulses with the organic molecules indole and toluene, and gases Xe, N2 and O2. Using multiphoton ionization cross sections extracted from these results, we show that the laser pulse parameters required for real-time detection of aromatic molecules at concentrations of one part per trillion in air and a limit of detection of a few attomoles are achievable with presently available commercial laser systems. The potential applications for the analysis of human breath, blood and tissue samples are discussed.

  17. Nature of gamma rays background radiation in new and old buildings of Qatar University

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Houty, L.; Abou-Leila, H.; El-Kameesy, S.

    Measurements and analysis of gamma-background radiation spectrum in four different places of Qatar University campus were performed at the energy range 10 keV-3 MeV using hyper pure Ge-detector. The dependence of the detector absolute photopeak efficiency on gamma-ray energies was determined and correction of the data for that was also done. The absorbed dose for each gamma line was calculated and an estimation of the total absorbed dose for the detected gamma lines in the four different places was obtained. Comparison with other results was also performed.

  18. Smartphone-based photoplethysmographic imaging for heart rate monitoring.

    PubMed

    Alafeef, Maha

    2017-07-01

    The purpose of this study is to make use of visible light reflected mode photoplethysmographic (PPG) imaging for heart rate (HR) monitoring via smartphones. The system uses the built-in camera feature in mobile phones to capture video from the subject's index fingertip. The video is processed, and then the PPG signal resulting from the video stream processing is used to calculate the subject's heart rate. Records from 19 subjects were used to evaluate the system's performance. The HR values obtained by the proposed method were compared with the actual HR. The obtained results show an accuracy of 99.7% and a maximum absolute error of 0.4 beats/min where most of the absolute errors lay in the range of 0.04-0.3 beats/min. Given the encouraging results, this type of HR measurement can be adopted with great benefit, especially in the conditions of personal use or home-based care. The proposed method represents an efficient portable solution for HR accurate detection and recording.

  19. Nanomolar detection of hypochlorite by a rhodamine-based chiral hydrazide in absolute aqueous media: application in tap water analysis with live-cell imaging.

    PubMed

    Goswami, Shyamaprosad; Das, Avijit Kumar; Manna, Abhishek; Maity, Anup Kumar; Saha, Partha; Quah, Ching Kheng; Fun, Hoong-Kun; Abdel-Aziz, Hatem A

    2014-07-01

    By employing the oxidation property of hypochlorite (OCl(-)), a novel rhodamine-based hydrazide of the chiral acid ((S)-(-)-2-pyrrolidone-5-carboxylic acid) (RHHP) was designed and synthesized for detection of OCl(-) absolutely in aqueous medium at nanomolar level. The structure of the chiral sensor was also proved by the X-ray crystallography. The bioactivity and the application of the probe for detection of OCl(-) in natural water system have been demonstrated. A plausible mechanism for oxidation of the sensor followed by hydrolysis is also proposed. The sensibility of the receptor toward OCl(-) was studied in absolute aqueous media, and the detection limit of hypochlorite-mediated oxidation to the receptor in nanomolar level makes this platform (RHHP) an ultrasensitive and unique system for OCl(-) oxidation.

  20. Characterization of 3-Aminopropyl Oligosilsesquioxane.

    PubMed

    Dimzon, Ian Ken D; Frömel, Tobias; Knepper, Thomas P

    2016-05-03

    The synthesis routes in the production of polysilsesquioxanes have largely relied upon in situ formations. This perspective often leads to polymers in which their basic structures including molecular weight and functionality are unknown [ Lichtenhan , J. D. ; et al. Silsesquioxane-siloxane copolymers from polyhedral silsesquioxanes Macromolecules , 1993 , 26 , 2141 - 2142 , http://dx.doi.org/10.1021/ma0060a053 ]. For a better understanding of the polysilsesquioxane properties and applications, there is a need to develop more techniques to enable their chemical characterization. An innovative method was developed to determine the molecular weight distribution (MWD) of an oligosilsesquioxane synthesized in-house from (3-aminopropyl)triethoxysilane. This method, which can be applied to other silsesquioxanes, siloxanes, and similar oligomers and polymers, involved separation using high performance liquid chromatography (HPLC) and detection using mass spectrometry (MS) with electrospray ionization (ESI). The novelty of the method lies on the unique determination of the absolute concentrations of the individual homologues present in the sample formulation. The use of absolute concentrations is necessary in estimating the MWD of the formulation when relative percentage, which is based solely on mass spectral ion intensities, becomes irrelevant due to the disproportionate response factors of the homologues. Determination of absolute concentration requires the use of single-homologue calibration standards. Because of commercial unavailability, these standards were prepared by efficient fractionation of the original formulation.

  1. Intensity correlation-based calibration of FRET.

    PubMed

    Bene, László; Ungvári, Tamás; Fedor, Roland; Sasi Szabó, László; Damjanovich, László

    2013-11-05

    Dual-laser flow cytometric resonance energy transfer (FCET) is a statistically efficient and accurate way of determining proximity relationships for molecules of cells even under living conditions. In the framework of this algorithm, absolute fluorescence resonance energy transfer (FRET) efficiency is determined by the simultaneous measurement of donor-quenching and sensitized emission. A crucial point is the determination of the scaling factor α responsible for balancing the different sensitivities of the donor and acceptor signal channels. The determination of α is not simple, requiring preparation of special samples that are generally different from a double-labeled FRET sample, or by the use of sophisticated statistical estimation (least-squares) procedures. We present an alternative, free-from-spectral-constants approach for the determination of α and the absolute FRET efficiency, by an extension of the presented framework of the FCET algorithm with an analysis of the second moments (variances and covariances) of the detected intensity distributions. A quadratic equation for α is formulated with the intensity fluctuations, which is proved sufficiently robust to give accurate α-values on a cell-by-cell basis in a wide system of conditions using the same double-labeled sample from which the FRET efficiency itself is determined. This seemingly new approach is illustrated by FRET measurements between epitopes of the MHCI receptor on the cell surface of two cell lines, FT and LS174T. The figures show that whereas the common way of α determination fails at large dye-per-protein labeling ratios of mAbs, this presented-as-new approach has sufficient ability to give accurate results. Although introduced in a flow cytometer, the new approach can also be straightforwardly used with fluorescence microscopes. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. Computationally Aided Absolute Stereochemical Determination of Enantioenriched Amines.

    PubMed

    Zhang, Jun; Gholami, Hadi; Ding, Xinliang; Chun, Minji; Vasileiou, Chrysoula; Nehira, Tatsuo; Borhan, Babak

    2017-03-17

    A simple and efficient protocol for sensing the absolute stereochemistry and enantiomeric excess of chiral monoamines is reported. Preparation of the sample requires a single-step reaction of the 1,1'-(bromomethylene)dinaphthalene (BDN) with the chiral amine. Analysis of the exciton coupled circular dichroism generated from the BDN-derivatized chiral amine sample, along with comparison to conformational analysis performed computationally, yields the absolute stereochemistry of the parent chiral monoamine.

  3. Is Efficiency Enough? Towards a New Framework for Carbon Savingsin the California Residential Sector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moezzi, Mithra; Diamond, Rick

    2005-10-01

    The overall implementation of energy efficiency in the United States is not adequately aligned with the environmental benefits claimed for efficiency, because it does not consider absolute levels of energy use, pollutant emissions, or consumption. In some ways, promoting energy efficiency may even encourage consumption. A more effective basis for environmental policy could be achieved by recognizing the degree and nature of the synchronization between environmental objectives and efficiency. This research seeks to motivate and initiate exploration of alternative ways of defining efficiency or otherwise moderating energy use toward reaching environmental objectives, as applicable to residential electricity use in California.more » The report offers three main recommendations: (1) produce definitions of efficiency that better integrate absolute consumption, (2) attend to the deeper social messages of energy efficiency communications, and (3) develop a more critical perspective on benefits and limitations of energy efficiency for delivering environmental benefits. In keeping with the exploratory nature of this project, the report also identifies ten questions for further investigation.« less

  4. Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration

    NASA Astrophysics Data System (ADS)

    Sabet, Mahsheed; Rowshanfarzad, Pejman; Vial, Philip; Menk, Frederick W.; Greer, Peter B.

    2012-08-01

    In this study an amorphous silicon electronic portal imaging device (a-Si EPID) converted to direct detection configuration was investigated as a transit dosimeter for intensity modulated radiation therapy (IMRT). After calibration to dose and correction for a background offset signal, the EPID-measured absolute IMRT transit doses for 29 fields were compared to a MatriXX two-dimensional array of ionization chambers (as reference) using Gamma evaluation (3%, 3 mm). The MatriXX was first evaluated as reference for transit dosimetry. The accuracy of EPID measurements was also investigated by comparison of point dose measurements by an ionization chamber on the central axis with slab and anthropomorphic phantoms in a range of simple to complex fields. The uncertainty in ionization chamber measurements in IMRT fields was also investigated by its displacement from the central axis and comparison with the central axis measurements. Comparison of the absolute doses measured by the EPID and MatriXX with slab phantoms in IMRT fields showed that on average 96.4% and 97.5% of points had a Gamma index<1 in head and neck and prostate fields, respectively. For absolute dose comparisons with anthropomorphic phantoms, the values changed to an average of 93.6%, 93.7% and 94.4% of points with Gamma index<1 in head and neck, brain and prostate fields, respectively. Point doses measured by the EPID and ionization chamber were within 3% difference for all conditions. The deviations introduced in the response of the ionization chamber in IMRT fields were<1%. The direct EPID performance for transit dosimetry showed that it has the potential to perform accurate, efficient and comprehensive in vivo dosimetry for IMRT.

  5. Lyman alpha SMM/UVSP absolute calibration and geocoronal correction

    NASA Technical Reports Server (NTRS)

    Fontenla, Juan M.; Reichmann, Edwin J.

    1987-01-01

    Lyman alpha observations from the Ultraviolet Spectrometer Polarimeter (UVSP) instrument of the Solar Maximum Mission (SMM) spacecraft were analyzed and provide instrumental calibration details. Specific values of the instrument quantum efficiency, Lyman alpha absolute intensity, and correction for geocoronal absorption are presented.

  6. Absolute charge calibration of scintillating screens for relativistic electron detection

    NASA Astrophysics Data System (ADS)

    Buck, A.; Zeil, K.; Popp, A.; Schmid, K.; Jochmann, A.; Kraft, S. D.; Hidding, B.; Kudyakov, T.; Sears, C. M. S.; Veisz, L.; Karsch, S.; Pawelke, J.; Sauerbrey, R.; Cowan, T.; Krausz, F.; Schramm, U.

    2010-03-01

    We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm2. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm2 was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

  7. Aeroelastic Model Structure Computation for Envelope Expansion

    NASA Technical Reports Server (NTRS)

    Kukreja, Sunil L.

    2007-01-01

    Structure detection is a procedure for selecting a subset of candidate terms, from a full model description, that best describes the observed output. This is a necessary procedure to compute an efficient system description which may afford greater insight into the functionality of the system or a simpler controller design. Structure computation as a tool for black-box modelling may be of critical importance in the development of robust, parsimonious models for the flight-test community. Moreover, this approach may lead to efficient strategies for rapid envelope expansion which may save significant development time and costs. In this study, a least absolute shrinkage and selection operator (LASSO) technique is investigated for computing efficient model descriptions of nonlinear aeroelastic systems. The LASSO minimises the residual sum of squares by the addition of an l(sub 1) penalty term on the parameter vector of the traditional 2 minimisation problem. Its use for structure detection is a natural extension of this constrained minimisation approach to pseudolinear regression problems which produces some model parameters that are exactly zero and, therefore, yields a parsimonious system description. Applicability of this technique for model structure computation for the F/A-18 Active Aeroelastic Wing using flight test data is shown for several flight conditions (Mach numbers) by identifying a parsimonious system description with a high percent fit for cross-validated data.

  8. An Observational Upper Limit on the Interstellar Number Density of Asteroids and Comets

    NASA Astrophysics Data System (ADS)

    Engelhardt, Toni; Jedicke, Robert; Vereš, Peter; Fitzsimmons, Alan; Denneau, Larry; Beshore, Ed; Meinke, Bonnie

    2017-03-01

    We derived 90% confidence limits (CLs) on the interstellar number density ({ρ }{IS}{CL}) of interstellar objects (ISOs; comets and asteroids) as a function of the slope of their size-frequency distribution (SFD) and limiting absolute magnitude. To account for gravitational focusing, we first generated a quasi-realistic ISO population to ˜ 750 {au} from the Sun and propagated it forward in time to generate a steady state population of ISOs with heliocentric distance < 50 {au}. We then simulated the detection of the synthetic ISOs using pointing data for each image and average detection efficiencies for each of three contemporary solar system surveys—Pan-STARRS1, the Mt. Lemmon Survey, and the Catalina Sky Survey. These simulations allowed us to determine the surveys’ combined ISO detection efficiency under several different but realistic modes of identifying ISOs in the survey data. Some of the synthetic detected ISOs had eccentricities as small as 1.01, which is in the range of the largest eccentricities of several known comets. Our best CL of {ρ }{IS}{CL}=1.4× {10}-4 {{au}}-3 implies that the expectation that extra-solar systems form like our solar system, eject planetesimals in the same way, and then distribute them throughout the Galaxy, is too simplistic, or that the SFD or behavior of ISOs as they pass through our solar system is far from expectation.

  9. The Absolute Spectrum Polarimeter (ASP)

    NASA Technical Reports Server (NTRS)

    Kogut, A. J.

    2010-01-01

    The Absolute Spectrum Polarimeter (ASP) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from 30 GHz to 5 THz. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much greater than 1O(raised to the power of { -3}) and Compton distortion y < 10 (raised to the power of{-6}). We describe the ASP instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

  10. Method For Detecting The Presence Of A Ferromagnetic Object

    DOEpatents

    Roybal, Lyle G.

    2000-11-21

    A method for detecting a presence or an absence of a ferromagnetic object within a sensing area may comprise the steps of sensing, during a sample time, a magnetic field adjacent the sensing area; producing surveillance data representative of the sensed magnetic field; determining an absolute value difference between a maximum datum and a minimum datum comprising the surveillance data; and determining whether the absolute value difference has a positive or negative sign. The absolute value difference and the corresponding positive or negative sign thereof forms a representative surveillance datum that is indicative of the presence or absence in the sensing area of the ferromagnetic material.

  11. Calibration and characterization of the IceCube photomultiplier tube

    NASA Astrophysics Data System (ADS)

    Abbasi, R.; Abdou, Y.; Abu-Zayyad, T.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Andeen, K.; Auffenberg, J.; Bai, X.; Baker, M.; Barwick, S. W.; Bay, R.; Bazo Alba, J. L.; Beattie, K.; Beatty, J. J.; Bechet, S.; Becker, J. K.; Becker, K.-H.; Benabderrahmane, M. L.; Berdermann, J.; Berghaus, P.; Berley, D.; Bernardini, E.; Bertrand, D.; Besson, D. Z.; Bissok, M.; Blaufuss, E.; Boersma, D. J.; Bohm, C.; Botner, O.; Bradley, L.; Braun, J.; Buitink, S.; Carson, M.; Chirkin, D.; Christy, B.; Clem, J.; Cohen, S.; Colnard, C.; Cowen, D. F.; D'Agostino, M. V.; Danninger, M.; de Clercq, C.; Demirörs, L.; Depaepe, O.; Descamps, F.; Desiati, P.; de Vries-Uiterweerd, G.; Deyoung, T.; Díaz-Vélez, J. C.; Dreyer, J.; Dumm, J. P.; Duvoort, M. R.; Ehrlich, R.; Eisch, J.; Ellsworth, R. W.; Engdegård, O.; Euler, S.; Evenson, P. A.; Fadiran, O.; Fazely, A. R.; Feusels, T.; Filimonov, K.; Finley, C.; Foerster, M. M.; Fox, B. D.; Franckowiak, A.; Franke, R.; Gaisser, T. K.; Gallagher, J.; Ganugapati, R.; Geisler, M.; Gerhardt, L.; Gladstone, L.; Goldschmidt, A.; Goodman, J. A.; Grant, D.; Griesel, T.; Groß, A.; Grullon, S.; Gunasingha, R. M.; Gurtner, M.; Ha, C.; Hallgren, A.; Halzen, F.; Han, K.; Hanson, K.; Hasegawa, Y.; Haugen, J.; Helbing, K.; Herquet, P.; Hickford, S.; Hill, G. C.; Hoffman, K. D.; Homeier, A.; Hoshina, K.; Hubert, D.; Huelsnitz, W.; Hülß, J.-P.; Hulth, P. O.; Hultqvist, K.; Hussain, S.; Imlay, R. L.; Inaba, M.; Ishihara, A.; Jacobsen, J.; Japaridze, G. S.; Johansson, H.; Joseph, J. M.; Kampert, K.-H.; Kappes, A.; Karg, T.; Karle, A.; Kelley, J. L.; Kemming, N.; Kenny, P.; Kiryluk, J.; Kislat, F.; Kitamura, N.; Klein, S. R.; Knops, S.; Kohnen, G.; Kolanoski, H.; Köpke, L.; Koskinen, D. J.; Kowalski, M.; Kowarik, T.; Krasberg, M.; Krings, T.; Kroll, G.; Kuehn, K.; Kuwabara, T.; Labare, M.; Lafebre, S.; Laihem, K.; Landsman, H.; Lauer, R.; Laundrie, A.; Lehmann, R.; Lennarz, D.; Lünemann, J.; Madsen, J.; Majumdar, P.; Maruyama, R.; Mase, K.; Matis, H. S.; Matusik, M.; Meagher, K.; Merck, M.; Mészáros, P.; Meures, T.; Middell, E.; Milke, N.; Miyamoto, H.; Montaruli, T.; Morse, R.; Movit, S. M.; Nahnhauer, R.; Nam, J. W.; Naumann, U.; Nießen, P.; Nygren, D. R.; Odrowski, S.; Olivas, A.; Olivo, M.; Ono, M.; Panknin, S.; Paul, L.; Pérez de Los Heros, C.; Petrovic, J.; Piegsa, A.; Pieloth, D.; Pohl, A. C.; Porrata, R.; Posselt, J.; Price, P. B.; Prikockis, M.; Przybylski, G. T.; Rawlins, K.; Redl, P.; Resconi, E.; Rhode, W.; Ribordy, M.; Rizzo, A.; Robl, P.; Rodrigues, J. P.; Roth, P.; Rothmaier, F.; Rott, C.; Roucelle, C.; Rutledge, D.; Ruzybayev, B.; Ryckbosch, D.; Sander, H.-G.; Sandstrom, P.; Sarkar, S.; Schatto, K.; Schlenstedt, S.; Schmidt, T.; Schneider, D.; Schukraft, A.; Schultes, A.; Schulz, O.; Schunck, M.; Seckel, D.; Semburg, B.; Seo, S. H.; Sestayo, Y.; Seunarine, S.; Silvestri, A.; Slipak, A.; Spiczak, G. M.; Spiering, C.; Stamatikos, M.; Stanev, T.; Stephens, G.; Stezelberger, T.; Stokstad, R. G.; Stoyanov, S.; Strahler, E. A.; Straszheim, T.; Sullivan, G. W.; Swillens, Q.; Taboada, I.; Tamburro, A.; Tarasova, O.; Tepe, A.; Ter-Antonyan, S.; Terranova, C.; Tilav, S.; Toale, P. A.; Tosi, D.; Turčan, D.; van Eijndhoven, N.; Vandenbroucke, J.; van Overloop, A.; van Santen, J.; Voigt, B.; Wahl, D.; Walck, C.; Waldenmaier, T.; Wallraff, M.; Walter, M.; Wendt, C.; Westerhoff, S.; Whitehorn, N.; Wiebe, K.; Wiebusch, C. H.; Wikström, G.; Williams, D. R.; Wischnewski, R.; Wissing, H.; Woschnagg, K.; Xu, C.; Xu, X. W.; Yodh, G.; Yoshida, S.; Zarzhitsky, P.; IceCube Collaboration

    2010-06-01

    Over 5000 PMTs are being deployed at the South Pole to compose the IceCube neutrino observatory. Many are placed deep in the ice to detect Cherenkov light emitted by the products of high-energy neutrino interactions, and others are frozen into tanks on the surface to detect particles from atmospheric cosmic ray showers. IceCube is using the 10-in. diameter R7081-02 made by Hamamatsu Photonics. This paper describes the laboratory characterization and calibration of these PMTs before deployment. PMTs were illuminated with pulses ranging from single photons to saturation level. Parameterizations are given for the single photoelectron charge spectrum and the saturation behavior. Time resolution, late pulses and afterpulses are characterized. Because the PMTs are relatively large, the cathode sensitivity uniformity was measured. The absolute photon detection efficiency was calibrated using Rayleigh-scattered photons from a nitrogen laser. Measured characteristics are discussed in the context of their relevance to IceCube event reconstruction and simulation efforts.

  12. Ultralow-power near-infrared excited neodymium-doped nanoparticles for long-term in vivo bioimaging.

    PubMed

    Qin, Qing-Song; Zhang, Pei-Zhi; Sun, Ling-Dong; Shi, Shuo; Chen, Nai-Xiu; Dong, Hao; Zheng, Xiao-Yu; Li, Le-Min; Yan, Chun-Hua

    2017-04-06

    Lanthanide-doped luminescent nanoparticles with both emission and excitation in the near-infrared (NIR-to-NIR) region hold great promise for bioimaging. Herein, core@shell structured LiLuF 4 :Nd@LiLuF 4 (named as Nd@Lu) nanoparticles (NPs) with highly efficient NIR emission were developed for high-performance in vivo bioimaging. Strikingly, the absolute quantum yield of Nd@Lu NPs reached as high as 32%. After coating with polyethylene glycol (PEG), the water-dispersible Nd@Lu NPs showed good bio-compatibility and low toxicity. With efficient NIR emission, the Nd@Lu NPs were clearly detectable in tissues at depths of up to 20 mm. In addition, long-term in vivo biodistribution with a high signal-to-noise ratio of 25.1 was distinctly tracked upon an ultralow-power-density excitation (10 mW cm -2 ) of 732 nm for the first time.

  13. Measurements of the Acoustic Speaking Voice After Vocal Warm-up and Cooldown in Choir Singers.

    PubMed

    Onofre, Fernanda; Prado, Yuka de Almeida; Rojas, Gleidy Vannesa E; Garcia, Denny Marco; Aguiar-Ricz, Lílian

    2017-01-01

    The aim of this study was to evaluate the acoustic measurements of the vowel /a/ in modal recording before and after a singing voice resistance test and after 30 minutes of absolute rest in female choir singers. This is a prospective cohort study. A total of 13 soprano choir singers with experience in choir singing were evaluated through analysis of acoustic voice parameters at three points in time: before continuous use of the voice, after vocal warm-up and a singing test 60 minutes in duration respecting the pauses for breathing, and after vocal cooldown and an absolute voice rest for 30 minutes. The fundamental frequency increased after the voice resistance test (P = 0.012) and remained elevated after the 30 minutes of voice rest (P = 0.01). The jitter decreased after the voice resistance test (P = 0.02) and after the 30 minutes of voice rest. A significant difference was detected for the acoustic voice parameters relative average perturbation (RAP), (P = 0.05), and pitch perturbation quotient (PPQ), (P = 0.04), compared with the initial time point. The fundamental frequency increased after 60 minutes of singing and remained elevated after vocal cooldown and absolute rest for 30 minutes, proving an efficient parameter for identifying the changes inherent to voice demand during singing. Copyright © 2017. Published by Elsevier Inc.

  14. Absolute S- and P-plane polarization efficiencies for high frequency holographic gratings in the VUV

    NASA Technical Reports Server (NTRS)

    Caruso, A. J.; Woodgate, B. E.; Mount, G. H.

    1981-01-01

    High frequency plane gratings (3500 and 3600 gr/mm) have been holographically ruled and blazed for the VUV spectral region. All gratings were coated with 70 nm Al + 25 nm MgF2. Absolute unpolarized and S- and P-plane polarization efficiencies have been measured for the first and second orders in the 120- to 450-nm spectral region at 18.5 and 30 deg angles of deviation. For deep grooves, anomalous features are more pronounced for the P-plane polarization efficiency than for the S-plane polarization efficiency. Holographic gratings can be tailored to produce high polarization or low polarization in the VUV. For comparison, efficiencies and polarization of the best conventional high frequency gratings were also determined. Measurements show that scattered light is significantly lower for holographic gratings in the VUV when compared with the conventional gratings.

  15. Detection of medically important Candida species by absolute quantitation real-time polymerase chain reaction.

    PubMed

    Than, Leslie Thian Lung; Chong, Pei Pei; Ng, Kee Peng; Seow, Heng Fong

    2015-01-01

    The number of invasive candidiasis cases has risen especially with an increase in the number of immunosuppressed and immunocom promised patients. The early detection of Candida species which is specific and sensitive is important in determining the correct administration of antifungal drugs to patients. This study aims to develop a method for the detection, identification and quantitation of medically important Candida species through quantitative polymerase chain reaction (qPCR). The isocitrate lyase (ICL) gene which is not found in mammals was chosen as the target gene of real-time PCR. Absolute quantitation of the gene copy number was achieved by constructing the plasmid containing the ICL gene which is used to generate standard curve. Twenty fungal species, two bacterial species and human DNA were tested to check the specificity of the detection method. All eight Candida species were successfully detected, identified and quantitated based on the ICL gene. A seven-log range of the gene copy number and a minimum detection limit of 10(3) copies were achieved. A one-tube absolute quantification real-time PCR that differentiates medically important Candida species via individual unique melting temperature was achieved. Analytical sensitivity and specificity were not compromised.

  16. Miniature fiber optic spectrometer-based quantitative fluorescence resonance energy transfer measurement in single living cells.

    PubMed

    Chai, Liuying; Zhang, Jianwei; Zhang, Lili; Chen, Tongsheng

    2015-03-01

    Spectral measurement of fluorescence resonance energy transfer (FRET), spFRET, is a widely used FRET quantification method in living cells today. We set up a spectrometer-microscope platform that consists of a miniature fiber optic spectrometer and a widefield fluorescence microscope for the spectral measurement of absolute FRET efficiency (E) and acceptor-to-donor concentration ratio (R(C)) in single living cells. The microscope was used for guiding cells and the spectra were simultaneously detected by the miniature fiber optic spectrometer. Moreover, our platform has independent excitation and emission controllers, so different excitations can share the same emission channel. In addition, we developed a modified spectral FRET quantification method (mlux-FRET) for the multiple donors and multiple acceptors FRET construct (mD∼nA) sample, and we also developed a spectra-based 2-channel acceptor-sensitized FRET quantification method (spE-FRET). We implemented these modified FRET quantification methods on our platform to measure the absolute E and R(C) values of tandem constructs with different acceptor/donor stoichiometries in single living Huh-7 cells.

  17. Auditory processing in absolute pitch possessors

    NASA Astrophysics Data System (ADS)

    McKetton, Larissa; Schneider, Keith A.

    2018-05-01

    Absolute pitch (AP) is a rare ability in classifying a musical pitch without a reference standard. It has been of great interest to researchers studying auditory processing and music cognition since it is seldom expressed and sheds light on influences pertaining to neurodevelopmental biological predispositions and the onset of musical training. We investigated the smallest frequency that could be detected or just noticeable difference (JND) between two pitches. Here, we report significant differences in JND thresholds in AP musicians and non-AP musicians compared to non-musician control groups at both 1000 Hz and 987.76 Hz testing frequencies. Although the AP-musicians did better than non-AP musicians, the difference was not significant. In addition, we looked at neuro-anatomical correlates of musicianship and AP using structural MRI. We report increased cortical thickness of the left Heschl's Gyrus (HG) and decreased cortical thickness of the inferior frontal opercular gyrus (IFO) and circular insular sulcus volume (CIS) in AP compared to non-AP musicians and controls. These structures may therefore be optimally enhanced and reduced to form the most efficient network for AP to emerge.

  18. Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC ESI-MS/MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Weiskittel, Taylor M.; Vavek, Marissa

    Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. Thesemore » values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction efficiency was calibrated for a given tissue type and drug, the droplet-based approach provides a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.« less

  19. Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC ESI-MS/MS

    DOE PAGES

    Kertesz, Vilmos; Weiskittel, Taylor M.; Vavek, Marissa; ...

    2016-06-22

    Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. Thesemore » values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction efficiency was calibrated for a given tissue type and drug, the droplet-based approach provides a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.« less

  20. Evaluation of absolute measurement using a 4π plastic scintillator for the 4πβ-γ coincidence counting method.

    PubMed

    Unno, Y; Sanami, T; Sasaki, S; Hagiwara, M; Yunoki, A

    2018-04-01

    Absolute measurement by the 4πβ-γ coincidence counting method was conducted by two photomultipliers facing across a plastic scintillator to be focused on β ray counting efficiency. The detector was held with a through-hole-type NaI(Tl) detector. The results include absolutely determined activity and its uncertainty especially about extrapolation. A comparison between the obtained and known activities showed agreement within their uncertainties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Fringe order correction for the absolute phase recovered by two selected spatial frequency fringe projections in fringe projection profilometry.

    PubMed

    Ding, Yi; Peng, Kai; Yu, Miao; Lu, Lei; Zhao, Kun

    2017-08-01

    The performance of the two selected spatial frequency phase unwrapping methods is limited by a phase error bound beyond which errors will occur in the fringe order leading to a significant error in the recovered absolute phase map. In this paper, we propose a method to detect and correct the wrong fringe orders. Two constraints are introduced during the fringe order determination of two selected spatial frequency phase unwrapping methods. A strategy to detect and correct the wrong fringe orders is also described. Compared with the existing methods, we do not need to estimate the threshold associated with absolute phase values to determine the fringe order error, thus making it more reliable and avoiding the procedure of search in detecting and correcting successive fringe order errors. The effectiveness of the proposed method is validated by the experimental results.

  2. Setting Whole-Building Absolute Energy Use Targets for the K-12 School, Retail, and Healthcare Sectors: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leach, M.; Bonnema, E.; Pless, S.

    2012-08-01

    This paper helps owners' efficiency representatives to inform executive management, contract development, and project management staff as to how specifying and applying whole-building absolute energy use targets for new construction or renovation projects can improve the operational energy performance of commercial buildings.

  3. Extraction of Organic Molecules from Terrestrial Material: Quantitative Yields from Heat and Water Extractions

    NASA Technical Reports Server (NTRS)

    Beegle, L. W.; Abbey, W. A.; Tsapin, A. T.; Dragoi, D.; Kanik, I.

    2004-01-01

    In the robotic search for life on Mars, different proposed missions will analyze the chemical and biological signatures of life using different platforms. The analysis of samples via analytical instrumentation on the surface of Mars has thus far only been attempted by the two Viking missions. Robotic arms scooped relogith material into a pyrolysis oven attached to a GC/MS. No trace of organic material was found on any of the two different samples at either of the two different landing sites. This null result puts an upper limit on the amount of organics that might be present in Martian soil/rocks, although the level of detection for each individual molecular species is still debated. Determining the absolute limit of detection for each analytical instrument is essential so that null results can be understood. This includes investigating the trade off of using pyrolysis versus liquid solvent extraction to release organic materials (in terms of extraction efficiencies and the complexity of the sample extraction process.) Extraction of organics from field samples can be accomplished by a variety of methods such utilizing various solvents including HCl, pure water, supercritical fluid and Soxhelt extraction. Utilizing 6N HCl is one of the most commonly used method and frequently utilized for extraction of organics from meteorites but it is probably infeasible for robotic exploration due to difficulty of storage and transport. Extraction utilizing H2O is promising, but it could be less efficient than 6N HCl. Both supercritical fluid and Soxhelt extraction methods require bulky hardware and require complex steps, inappropriate for inclusion on rover spacecraft. This investigation reports the efficiencies of pyrolysis and solvent extraction methods for amino acids for different terrestrial samples. The samples studied here, initially created in aqueous environments, are sedimentary in nature. These particular samples were chosen because they possibly represent one of the best terrestrial analogs of Mars and they represent one of the absolute best case scenarios for finding organic molecules on the Martian surface.

  4. Detection efficiency of microchannel plates for e{sup −} and π{sup −} in the momentum range from 17.5 to 345 MeV/c

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tulej, M., E-mail: marek.tulej@space.unibe.ch; Meyer, S.; Lüthi, M.

    2015-08-15

    High-energy e{sup –} and π{sup –} were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% ± 0.5% for electrons in the beam momenta range 17.5–300 MeV/c and 6.0% ± 1.3% for pions in the beam momenta range 172–345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere insidemore » the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter’s magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution.« less

  5. Aeroelastic Model Structure Computation for Envelope Expansion

    NASA Technical Reports Server (NTRS)

    Kukreja, Sunil L.

    2007-01-01

    Structure detection is a procedure for selecting a subset of candidate terms, from a full model description, that best describes the observed output. This is a necessary procedure to compute an efficient system description which may afford greater insight into the functionality of the system or a simpler controller design. Structure computation as a tool for black-box modeling may be of critical importance in the development of robust, parsimonious models for the flight-test community. Moreover, this approach may lead to efficient strategies for rapid envelope expansion that may save significant development time and costs. In this study, a least absolute shrinkage and selection operator (LASSO) technique is investigated for computing efficient model descriptions of non-linear aeroelastic systems. The LASSO minimises the residual sum of squares with the addition of an l(Sub 1) penalty term on the parameter vector of the traditional l(sub 2) minimisation problem. Its use for structure detection is a natural extension of this constrained minimisation approach to pseudo-linear regression problems which produces some model parameters that are exactly zero and, therefore, yields a parsimonious system description. Applicability of this technique for model structure computation for the F/A-18 (McDonnell Douglas, now The Boeing Company, Chicago, Illinois) Active Aeroelastic Wing project using flight test data is shown for several flight conditions (Mach numbers) by identifying a parsimonious system description with a high percent fit for cross-validated data.

  6. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    NASA Astrophysics Data System (ADS)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald

    2015-08-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.

  7. Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: what level is achievable?

    PubMed

    van Battum, L J; Hoffmans, D; Piersma, H; Heukelom, S

    2008-02-01

    This paper focuses on the accuracy, in absolute dose measurements, with GafChromicTM EBT film achievable in water for a 6 MV photon beam up to a dose of 2.3 Gy. Motivation is to get an absolute dose detection system to measure up dose distributions in a (water) phantom, to check dose calculations. An Epson 1680 color (red green blue) transmission flatbed scanner has been used as film scanning system, where the response in the red color channel has been extracted and used for the analyses. The influence of the flatbed film scanner on the film based dose detection process was investigated. The scan procedure has been optimized; i.e. for instance a lateral correction curve was derived to correct the scan value, up to 10%, as a function of optical density and lateral position. Sensitometric curves of different film batches were evaluated in portrait and landscape scan mode. Between various batches important variations in sensitometric curve were observed. Energy dependence of the film is negligible, while a slight variation in dose response is observed for very large angles between film surface and incident photon beam. Improved accuracy in absolute dose detection can be obtained by repetition of a film measurement to tackle at least the inherent presence of film inhomogeneous construction. We state that the overall uncertainty is random in absolute EBT film dose detection and of the order of 1.3% (1 SD) under the condition that the film is scanned in a limited centered area on the scanner and at least two films have been applied. At last we advise to check a new film batch on its characteristics compared to available information, before using that batch for absolute dose measurements.

  8. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance.

    PubMed

    Thiéry, Guillaume; Boyer, Alexandre; Pigné, Etienne; Salah, Amar; De Lassence, Arnaud; Dreyfuss, Didier; Ricard, Jean-Damien

    2003-03-01

    To determine whether use of a hygroscopic and hydrophobic heat and moisture exchanger (HME) for 7 days without change affects its efficiency in long-term, mechanically ventilated, chronic obstructive pulmonary disease (COPD) patients. Prospective, randomized, controlled clinical study comparing two combined HMEs. Medical intensive care unit at a university teaching hospital. Long-term, mechanically ventilated, COPD patients compared with non-COPD patients. In the first part of the study, COPD patients were studied with the Hygroster HME changed once a week. For the second part, the Hygroster was assessed in non-COPD patients and compared with the Hygrobac HME used in COPD and non-COPD patients for 1 wk without change. Devices could be changed if hygrometric measurements indicated insufficient humidity delivery. Daily measurements were recorded for inspired gas temperature and relative and absolute humidity. Ventilatory variables, clinical indicators of efficient humidification, were also recorded. No tracheal tube occlusion occurred. However, contrary to the manufacturer advertisement, the Hygroster experienced surprisingly low values for absolute humidity in both COPD and non-COPD patients. Such events did not occur with the Hygrobac. Absolute humidity with the Hygroster was constantly and significantly lower during the 7-day study period than with the Hygrobac. Absolute humidity measured in COPD patients was identical to that measured in the rest of the study population with both HMEs. Manufacturer specifications and bedside measurements of absolute humidity differed considerably for the Hygroster, which in certain instances did not achieve efficient humidification in both COPD and non-COPD patients. This did not occur with the Hygrobac, which performed well throughout the 7-day period in both COPD and non-COPD patients. Our results speak for independent and evaluation of HMEs.

  9. Dependence of hydrogen arcjet operation on electrode geometry

    NASA Technical Reports Server (NTRS)

    Pencil, Eric J.; Sankovic, John M.; Sarmiento, Charles J.; Hamley, John A.

    1992-01-01

    The dependence of 2kW hydrogen arcjet performance on cathode to anode electrode spacing was evaluated at specific impulses of 900 and 1000 s. Less than 2 absolute percent change in efficiency was measured for the spacings tested which did not repeat the 14 absolute percent variation reported in earlier work with similar electrode designs. A different nozzle configuration was used to quantify the variation in hydrogen arcjet performance over an extended range of electrode spacing. Electrode gap variation resulted in less than 3 absolute percent change in efficiency. These null results suggested that electrode spacing is decoupled from hydrogen arcjet ignition. The dependence of breakdown voltage on mass flow rate and electrode agreed with Paschen curves for hydrogen. Preliminary characterization of the dependence of hydrogen arcjet ignition on rates of pulse repetition and pulse voltage rise were also included for comparison with previous results obtained using simulated hydrazine.

  10. Dependence of hydrogen arcjet operation on electrode geometry

    NASA Technical Reports Server (NTRS)

    Pencil, Eric J.; Sankovic, John M.; Sarmiento, Charles J.; Hamley, John A.

    1992-01-01

    The dependence of 2 kW hydrogen arcjet performance on cathode to anode electrode spacing was evaluated at specific impulses of 900 and 1000 s. Less than 2 absolute percent change in efficiency was measured for the spacings tested which did not repeat the 14 absolute percent variation reported in earlier work with similar electrode designs. A different nozzle configuration was used to quantify the variation in hydrogen arcjet performance over an extended range of electrode spacing. Electrode gap variation resulted in less than 3 absolute percent change in efficiency. These null results suggested that electrode spacing is decoupled from hydrogen arcjet performance considerations over the ranges tested. Initial studies were conducted on hydrogen arcjet ignition. The dependence of breakdown voltage on mass flow rate and hydrogen arcjet ignition on rates of pulse repetition and pulse voltage rise were also included for comparison with previous results obtained using simulated hydrazine.

  11. Localised excitation of a single photon source by a nanowaveguide.

    PubMed

    Geng, Wei; Manceau, Mathieu; Rahbany, Nancy; Sallet, Vincent; De Vittorio, Massimo; Carbone, Luigi; Glorieux, Quentin; Bramati, Alberto; Couteau, Christophe

    2016-01-29

    Nowadays, integrated photonics is a key technology in quantum information processing (QIP) but achieving all-optical buses for quantum networks with efficient integration of single photon emitters remains a challenge. Photonic crystals and cavities are good candidates but do not tackle how to effectively address a nanoscale emitter. Using a nanowire nanowaveguide, we realise an hybrid nanodevice which locally excites a single photon source (SPS). The nanowire acts as a passive or active sub-wavelength waveguide to excite the quantum emitter. Our results show that localised excitation of a SPS is possible and is compared with free-space excitation. Our proof of principle experiment presents an absolute addressing efficiency ηa ~ 10(-4) only ~50% lower than the one using free-space optics. This important step demonstrates that sufficient guided light in a nanowaveguide made of a semiconductor nanowire is achievable to excite a single photon source. We accomplish a hybrid system offering great potentials for electrically driven SPSs and efficient single photon collection and detection, opening the way for optimum absorption/emission of nanoscale emitters. We also discuss how to improve the addressing efficiency of a dipolar nanoscale emitter with our system.

  12. Localised excitation of a single photon source by a nanowaveguide

    PubMed Central

    Geng, Wei; Manceau, Mathieu; Rahbany, Nancy; Sallet, Vincent; De Vittorio, Massimo; Carbone, Luigi; Glorieux, Quentin; Bramati, Alberto; Couteau, Christophe

    2016-01-01

    Nowadays, integrated photonics is a key technology in quantum information processing (QIP) but achieving all-optical buses for quantum networks with efficient integration of single photon emitters remains a challenge. Photonic crystals and cavities are good candidates but do not tackle how to effectively address a nanoscale emitter. Using a nanowire nanowaveguide, we realise an hybrid nanodevice which locally excites a single photon source (SPS). The nanowire acts as a passive or active sub-wavelength waveguide to excite the quantum emitter. Our results show that localised excitation of a SPS is possible and is compared with free-space excitation. Our proof of principle experiment presents an absolute addressing efficiency ηa ~ 10−4 only ~50% lower than the one using free-space optics. This important step demonstrates that sufficient guided light in a nanowaveguide made of a semiconductor nanowire is achievable to excite a single photon source. We accomplish a hybrid system offering great potentials for electrically driven SPSs and efficient single photon collection and detection, opening the way for optimum absorption/emission of nanoscale emitters. We also discuss how to improve the addressing efficiency of a dipolar nanoscale emitter with our system. PMID:26822999

  13. Absolute efficiency calibration of 6LiF-based solid state thermal neutron detectors

    NASA Astrophysics Data System (ADS)

    Finocchiaro, Paolo; Cosentino, Luigi; Lo Meo, Sergio; Nolte, Ralf; Radeck, Desiree

    2018-03-01

    The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations of thermal neutron detectors, characterized by reasonable efficiency and gamma rejection comparable to 3He tubes. In this paper we show the state of the art of a promising low-cost technique, based on commercial solid state silicon detectors coupled with thin neutron converter layers of 6LiF deposited onto carbon fiber substrates. A few configurations were studied with the GEANT4 simulation code, and the intrinsic efficiency of the corresponding detectors was calibrated at the PTB Thermal Neutron Calibration Facility. The results show that the measured intrinsic detection efficiency is well reproduced by the simulations, therefore validating the simulation tool in view of new designs. These neutron detectors have also been tested at neutron beam facilities like ISIS (Rutherford Appleton Laboratory, UK) and n_TOF (CERN) where a few samples are already in operation for beam flux and 2D profile measurements. Forthcoming applications are foreseen for the online monitoring of spent nuclear fuel casks in interim storage sites.

  14. Enantiomeric high-performance liquid chromatography resolution and absolute configuration of 6β-benzoyloxy-3α-tropanol.

    PubMed

    Muñoz, Marcelo A; González, Natalia; Joseph-Nathan, Pedro

    2016-07-01

    The absolute configuration of the naturally occurring isomers of 6β-benzoyloxy-3α-tropanol (1) has been established by the combined use of chiral high-performance liquid chromatography with electronic circular dichroism detection and optical rotation detection. For this purpose (±)-1, prepared in two steps from racemic 6-hydroxytropinone (4), was subjected to chiral high-performance liquid chromatography with electronic circular dichroism and optical rotation detection allowing the online measurement of both chiroptical properties for each enantiomer, which in turn were compared with the corresponding values obtained from density functional theory calculations. In an independent approach, preparative high-performance liquid chromatography separation using an automatic fraction collector, yielded an enantiopure sample of OR (+)-1 whose vibrational circular dichroism spectrum allowed its absolute configuration assignment when the bands in the 1100-950 cm(-1) region were compared with those of the enantiomers of esters derived from 3α,6β-tropanediol. In addition, an enantiomerically enriched sample of 4, instead of OR (±)-4, was used for the same transformation sequence, whose high-performance liquid chromatography follow-up allowed their spectroscopic correlation. All evidences lead to the OR (+)-(1S,3R,5S,6R) and OR (-)-(1R,3S,5R,6S) absolute configurations, from where it follows that samples of 1 isolated from Knightia strobilina and Erythroxylum zambesiacum have the OR (+)-(1S,3R,5S,6R) absolute configuration, while the sample obtained from E. rotundifolium has the OR (-)-(1R,3S,5R,6S) absolute configuration. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Early diagnosis of severe combined immunodeficiency (SCID) in Turkey: a pilot study.

    PubMed

    Can, Ceren; Hamilçıkan, Şahin; Can, Emrah

    2017-08-29

    Severe combined immunodeficiency (SCID) is a neonatal emergency. As the T-cell receptor excision circles (TREC) test is not cost effective for neonatal screening of SCID in developing countries, this pilot study's objective aimed at identifying preliminary data to enable SCID identification in the general population. This observational study was performed in Bagcılar Training and Research Hospital, Istanbul, Turkey. Cord-blood complete blood count (CBC) was recorded in all neonates included in the study. Absolute lymphopenia was considered in cord-blood samples if the absolute lymphocyte count was less than 2500/mm 3 . A control blood count was performed 1-month later for cases with detected lymphopenia. A total of 2945 term neonates were included in the study. Absolute lymphopenia was found in nine (0.3%) neonates, while 2936 (99.7%) had an absolute lymphocytic count above 2.5 × 10 3 /mm 3 . The mean counts of red blood cells (RBC), hemoglobin (HGB), hematocrit (HCT), platelets (PLT), and monocytes in the lymphopenia group were not found to significantly differ from the non-lymphopenia group. However, there were significantly lower mean white blood cell (WBC), lymphocyte, and neutrophil counts between the groups (p < .05). Absolute lymphopenia detected using CBC analysis is a simple, easier, more non-invasive, and cheaper method than the TREC method for detection of SCID neonates, and this method may prove to be a useful alternative, especially in developing countries.

  16. Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification.

    PubMed

    Guan, Weihua; Chen, Liben; Rane, Tushar D; Wang, Tza-Huei

    2015-09-03

    We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples.

  17. Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification

    PubMed Central

    Guan, Weihua; Chen, Liben; Rane, Tushar D.; Wang, Tza-Huei

    2015-01-01

    We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples. PMID:26333806

  18. Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification

    NASA Astrophysics Data System (ADS)

    Guan, Weihua; Chen, Liben; Rane, Tushar D.; Wang, Tza-Huei

    2015-09-01

    We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples.

  19. Improved methods of AAV-mediated gene targeting for human cell lines using ribosome-skipping 2A peptide

    PubMed Central

    Karnan, Sivasundaram; Ota, Akinobu; Konishi, Yuko; Wahiduzzaman, Md; Hosokawa, Yoshitaka; Konishi, Hiroyuki

    2016-01-01

    The adeno-associated virus (AAV)-based targeting vector has been one of the tools commonly used for genome modification in human cell lines. It allows for relatively efficient gene targeting associated with 1–4-log higher ratios of homologous-to-random integration of targeting vectors (H/R ratios) than plasmid-based targeting vectors, without actively introducing DNA double-strand breaks. In this study, we sought to improve the efficiency of AAV-mediated gene targeting by introducing a 2A-based promoter-trap system into targeting constructs. We generated three distinct AAV-based targeting vectors carrying 2A for promoter trapping, each targeting a GFP-based reporter module incorporated into the genome, PIGA exon 6 or PIGA intron 5. The absolute gene targeting efficiencies and H/R ratios attained using these vectors were assessed in multiple human cell lines and compared with those attained using targeting vectors carrying internal ribosome entry site (IRES) for promoter trapping. We found that the use of 2A for promoter trapping increased absolute gene targeting efficiencies by 3.4–28-fold and H/R ratios by 2–5-fold compared to values obtained with IRES. In CRISPR-Cas9-assisted gene targeting using plasmid-based targeting vectors, the use of 2A did not enhance the H/R ratios but did upregulate the absolute gene targeting efficiencies compared to the use of IRES. PMID:26657635

  20. Preliminary investigation of the performance of a single tubular combustor at pressure up to 12 atmospheres

    NASA Technical Reports Server (NTRS)

    Wear, Jerrold D; Butze, Helmut F

    1954-01-01

    The effects of combustor operation at conditions representative of those encountered in high pressure-ratio turbojet engines or at high flight speeds on carbon deposition, exhaust smoke, and combustion efficiency were studied in a single tubular combustor. Carbon deposition and smoke formation tests were conducted over a range of combustor-inlet pressures from 33 to 173 pounds per square inch absolute and combustor reference velocities from 78 to 143 feet per second. Combustion efficiency tests were conducted over a range of pressures from 58 to 117 pounds per square inch absolute and velocities from 89 to 172 feet per second.

  1. Determination of the absolute internal quantum efficiency of photoluminescence in GaN co-doped with Si and Zn

    NASA Astrophysics Data System (ADS)

    Reshchikov, M. A.; Foussekis, M.; McNamara, J. D.; Behrends, A.; Bakin, A.; Waag, A.

    2012-04-01

    The optical properties of high-quality GaN co-doped with silicon and zinc are investigated by using temperature-dependent continuous-wave and time-resolved photoluminescence measurements. The blue luminescence band is related to the ZnGa acceptor in GaN:Si,Zn, which exhibits an exceptionally high absolute internal quantum efficiency (IQE). An IQE above 90% was calculated for several samples having different concentrations of Zn. Accurate and reliable values of the IQE were obtained by using several approaches based on rate equations. The concentrations of the ZnGa acceptors and free electrons were also estimated from the photoluminescence measurements.

  2. Absolute Effect of Prostate Cancer Screening: Balance of benefits and harms by center within the European Randomized Study of Prostate Cancer Screening

    PubMed Central

    Auvinen, Anssi; Moss, Sue M; Tammela, Teuvo L J; Taari, Kimmo; Roobol, Monique J; Schröder, Fritz H; Bangma, Chris H; Carlsson, Sigrid; Aus, Gunnar; Zappa, Marco; Puliti, Donella; Denis, Louis J; Nelen, Vera; Kwiatkowski, Maciej; Randazzo, Marco; Paez, Alvaro; Lujan, Marcos; Hugosson, Jonas

    2016-01-01

    Purpose The balance of benefits and harms in prostate cancer screening has not been sufficiently characterized. We related indicators of mortality reduction and overdetection by center within the European Randomized Study of Prostate Cancer Screening. Experimental Design We analyzed the absolute mortality reduction expressed as number needed to invite (NNI=1/absolute risk reduction; indicating how many men had to be randomized to screening arm to avert a prostate cancer death) for screening and the absolute excess of prostate cancer detection as number needed for overdetection (NNO=1/absolute excess incidence; indicating the number of men invited per additional prostate cancer case), and compared their relationship across the seven ERSPC centers. Results Both absolute mortality reduction (NNI) and absolute overdetection (NNO) varied widely between the centers: NNI 200-7000 and NNO 16-69. Extent of overdiagnosis and mortality reduction were closely associated (correlation coefficient r=0.76, weighted linear regression coefficient β=33, 95% 5-62, R2=0.72). For an averted prostate cancer death at 13 years of follow-up, 12-36 excess cases had to be detected in various centers. Conclusions The differences between the ERSPC centers likely reflect variations in prostate cancer incidence and mortality, as well as in screening protocol and performance. The strong interrelation between the benefits and harms suggests that efforts to maximize the mortality effect are bound to increase overdiagnosis, and might be improved by focusing on high-risk populations. The optimal balance between screening intensity and risk of overdiagnosis remains unclear. PMID:26289069

  3. The effect of household poverty on tuberculosis.

    PubMed

    Siroka, A; Law, I; Macinko, J; Floyd, K; Banda, R P; Hoa, N B; Tsolmon, B; Chanda-Kapata, P; Gasana, M; Lwinn, T; Senkoro, M; Tupasi, T; Ponce, N A

    2016-12-01

    pSETTING: Households in Malawi, Mongolia, Myanmar, the Philippines, Rwanda, Tanzania, Viet Nam and Zambia.OBJECTIVE To assess the relationship between household socio-economic level, both relative and absolute, and individual tuberculosis (TB) disease. We analysed national TB prevalence surveys from eight countries individually and in pooled multicountry models. Socio-economic level (SEL) was measured in terms of both relative household position and absolute wealth. The outcome of interest was whether or not an individual had TB disease. Logistic regression models were used to control for putative risk factors for TB disease such as age, sex and previous treatment history. Overall, a strong and consistent association between household SEL and individual TB disease was not found. Significant results were found in four individual country models, with the lowest socio-economic quintile being associated with higher TB risk in Mongolia, Myanmar, Tanzania and Viet Nam. TB prevalence surveys are designed to assess prevalence of disease and, due to the small numbers of cases usually detected, may not be the most efficient means of investigating TB risk factors. Different designs are needed, including measuring the SEL of individuals in nested case-control studies within TB prevalence surveys or among TB patients seeking treatment in health care facilities.

  4. The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: a systematic review.

    PubMed

    Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline

    2013-06-01

    What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.

  5. Resistive Plate Chambers as thermal neutron detectors

    NASA Astrophysics Data System (ADS)

    Abbrescia, M.; Mongelli, T.; Paticchio, V.; Ranieri, A.; Trentadue, R.

    2003-09-01

    We present a construction procedure suitable to make Resistive Plate Chambers detectors sensitive also to thermal neutrons. This procedure, consisting in coating the inner surface of one of the RPC Bakelite electrodes with a mixture of linseed oil and Gd203, is very simple, cheap, and suitable to be employed for industrial, medical or de-mining applications. Here the results of extensive tests aimed to asset the performance of two prototypes of Gd-RPCs are shown. While the detection efficiency to thermal neutrons for a standard not Gd-coated RPC results to be about 0.1%, Gd-RPCs reach, in stand-alone, absolute efficiencies of about 10%, and, when two of these detectors are coupled together, more than 15%. In addition RPCs have excellent time resolution and good imaging performance. This new type, position sensitive gas detector can be operated at atmospheric pressure, is light-weighted, has low γ-ray sensitivity, and is easy to build and handle even when large areas are to be covered.

  6. MEERCAT: Multiplexed Efficient Cell Free Expression of Recombinant QconCATs For Large Scale Absolute Proteome Quantification*

    PubMed Central

    Takemori, Nobuaki; Takemori, Ayako; Tanaka, Yuki; Endo, Yaeta; Hurst, Jane L.; Gómez-Baena, Guadalupe; Harman, Victoria M.; Beynon, Robert J.

    2017-01-01

    A major challenge in proteomics is the absolute accurate quantification of large numbers of proteins. QconCATs, artificial proteins that are concatenations of multiple standard peptides, are well established as an efficient means to generate standards for proteome quantification. Previously, QconCATs have been expressed in bacteria, but we now describe QconCAT expression in a robust, cell-free system. The new expression approach rescues QconCATs that previously were unable to be expressed in bacteria and can reduce the incidence of proteolytic damage to QconCATs. Moreover, it is possible to cosynthesize QconCATs in a highly-multiplexed translation reaction, coexpressing tens or hundreds of QconCATs simultaneously. By obviating bacterial culture and through the gain of high level multiplexing, it is now possible to generate tens of thousands of standard peptides in a matter of weeks, rendering absolute quantification of a complex proteome highly achievable in a reproducible, broadly deployable system. PMID:29055021

  7. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...

  8. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...

  9. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...

  10. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...

  11. 40 CFR 1065.345 - Vacuum-side leak verification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...

  12. Dynamic planar solid phase microextraction-ion mobility spectrometry for rapid field air sampling and analysis of illicit drugs and explosives.

    PubMed

    Guerra-Diaz, Patricia; Gura, Sigalit; Almirall, José R

    2010-04-01

    A preconcentration device that targets the volatile chemical signatures associated with illicit drugs and explosives (high and low) has been designed to fit in the inlet of an ion mobility spectrometer (IMS). This is the first reporting of a fast and sensitive method for dynamic sampling of large volumes of air using planar solid phase microextraction (PSPME) incorporating a high surface area for absorption of analytes onto a sol-gel polydimethylsiloxane (PDMS) coating for direct thermal desorption into an IMS. This device affords high extraction efficiencies due to strong retention properties at ambient temperature, resulting in the detection of analyte concentrations in the parts per trillion range when as low as 3.5 L of air are sampled over the course of 10 s (absolute mass detection of less than a nanogram). Dynamic PSPME was used to sample the headspace over the following: 3,4-methylenedioxymethamphetamine (MDMA) tablets resulting in the detection of 12-40 ng of piperonal, high explosives (Pentolite) resulting in the detection of 0.6 ng of 2,4,6-trinitrotoluene (TNT), and low explosives (several smokeless powders) resulting in the detection of 26-35 ng of 2,4-dinitrotoluene (2,4-DNT) and 11-74 ng of diphenylamine (DPA).

  13. Chloride interference in the determination of bromate in drinking water by reagent free ion chromatography with mass spectrometry detection.

    PubMed

    Cavalli, Silvano; Polesello, Stefano; Valsecchi, Sara

    2005-08-26

    Bromate, a well known by-product of the ozonation of drinking water, has been included among the substances which have to be monitored in the drinking water according to the last EC Directive 251/98 on potable water with a regulated limit of 10 microg l(-1). The need of performing routine analysis at this limit is a driving force for the developing of new simple and sensitive methods of detection, which should be also able to overcome the effect of matrix composition. This work explored the use of mass spectrometry detection with electrospray ionisation hyphenated to a reagent free ion chromatograph with hydroxide gradient elution for the determination of bromate in drinking water. The use of a high capacity hydroxide selective column operated in gradient mode allowed to avoid the interference by carbonate peak, which moved to longer retention times. The effect of increasing chloride concentrations from 0 to 250 mg l(-1), which is the guideline limit for drinking water in Directive 251/98/EC, was to decrease absolute mass spectrometric response and chromatographic efficiency and, on the consequence, to increase the effective detection limits. The effect of the chloride concentration on the detection of bromate is discussed.

  14. Prion subcellular fractionation reveals infectivity spectrum, with a high titre-low PrPres level disparity

    PubMed Central

    2012-01-01

    Background Prion disease transmission and pathogenesis are linked to misfolded, typically protease resistant (PrPres) conformers of the normal cellular prion protein (PrPC), with the former posited to be the principal constituent of the infectious 'prion'. Unexplained discrepancies observed between detectable PrPres and infectivity levels exemplify the complexity in deciphering the exact biophysical nature of prions and those host cell factors, if any, which contribute to transmission efficiency. In order to improve our understanding of these important issues, this study utilized a bioassay validated cell culture model of prion infection to investigate discordance between PrPres levels and infectivity titres at a subcellular resolution. Findings Subcellular fractions enriched in lipid rafts or endoplasmic reticulum/mitochondrial marker proteins were equally highly efficient at prion transmission, despite lipid raft fractions containing up to eight times the levels of detectable PrPres. Brain homogenate infectivity was not differentially enhanced by subcellular fraction-specific co-factors, and proteinase K pre-treatment of selected fractions modestly, but equally reduced infectivity. Only lipid raft associated infectivity was enhanced by sonication. Conclusions This study authenticates a subcellular disparity in PrPres and infectivity levels, and eliminates simultaneous divergence of prion strains as the explanation for this phenomenon. On balance, the results align best with the concept that transmission efficiency is influenced more by intrinsic characteristics of the infectious prion, rather than cellular microenvironment conditions or absolute PrPres levels. PMID:22534096

  15. Nuclear-Recoil Energy Scale in CDMS II Silicon Dark-Matter Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnese, R.; et al.

    The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrummore » $$^{252}$$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $$4.8^{+0.7}_{-0.9}$$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $$\\sim$$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $$\\sim$$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.« less

  16. Two-stage sparse coding of region covariance via Log-Euclidean kernels to detect saliency.

    PubMed

    Zhang, Ying-Ying; Yang, Cai; Zhang, Ping

    2017-05-01

    In this paper, we present a novel bottom-up saliency detection algorithm from the perspective of covariance matrices on a Riemannian manifold. Each superpixel is described by a region covariance matrix on Riemannian Manifolds. We carry out a two-stage sparse coding scheme via Log-Euclidean kernels to extract salient objects efficiently. In the first stage, given background dictionary on image borders, sparse coding of each region covariance via Log-Euclidean kernels is performed. The reconstruction error on the background dictionary is regarded as the initial saliency of each superpixel. In the second stage, an improvement of the initial result is achieved by calculating reconstruction errors of the superpixels on foreground dictionary, which is extracted from the first stage saliency map. The sparse coding in the second stage is similar to the first stage, but is able to effectively highlight the salient objects uniformly from the background. Finally, three post-processing methods-highlight-inhibition function, context-based saliency weighting, and the graph cut-are adopted to further refine the saliency map. Experiments on four public benchmark datasets show that the proposed algorithm outperforms the state-of-the-art methods in terms of precision, recall and mean absolute error, and demonstrate the robustness and efficiency of the proposed method. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized 3He neutron spin-filter

    NASA Astrophysics Data System (ADS)

    Musgrave, M. M.; Baeßler, S.; Balascuta, S.; Barrón-Palos, L.; Blyth, D.; Bowman, J. D.; Chupp, T. E.; Cianciolo, V.; Crawford, C.; Craycraft, K.; Fomin, N.; Fry, J.; Gericke, M.; Gillis, R. C.; Grammer, K.; Greene, G. L.; Hamblen, J.; Hayes, C.; Huffman, P.; Jiang, C.; Kucuker, S.; McCrea, M.; Mueller, P. E.; Penttilä, S. I.; Snow, W. M.; Tang, E.; Tang, Z.; Tong, X.; Wilburn, W. S.

    2018-07-01

    Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of ∼ 109 neutrons per second per cm2 and a cross sectional area of 10 × 12 cm2. The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized 3He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the 3He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured in this work were done for the NPDGamma experiment, which measures the parity violating γ-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. The experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.

  18. Levelized cost of energy (LCOE) metric to characterize solar absorber coatings for the CSP industry

    DOE PAGES

    Boubault, Antoine; Ho, Clifford K.; Hall, Aaron; ...

    2015-07-08

    The contribution of each component of a power generation plant to the levelized cost of energy (LCOE) can be estimated and used to increase the power output while reducing system operation and maintenance costs. The LCOE is used in order to quantify solar receiver coating influence on the LCOE of solar power towers. Two new parameters are introduced: the absolute levelized cost of coating (LCOC) and the LCOC efficiency. Depending on the material properties, aging, costs, and temperature, the absolute LCOC enables quantifying the cost-effectiveness of absorber coatings, as well as finding optimal operating conditions. The absolute LCOC is investigatedmore » for different hypothetic coatings and is demonstrated on Pyromark 2500 paint. Results show that absorber coatings yield lower LCOE values in most cases, even at significant costs. Optimal reapplication intervals range from one to five years. At receiver temperatures greater than 700 °C, non-selective coatings are not always worthwhile while durable selective coatings consistently reduce the LCOE—up to 12% of the value obtained for an uncoated receiver. Moreover the absolute LCOC is a powerful tool to characterize and compare different coatings, not only considering their initial efficiencies but also including their durability.« less

  19. Genital shedding of human immunodeficiency virus type 1 DNA during pregnancy: association with immunosuppression, abnormal cervical or vaginal discharge, and severe vitamin A deficiency.

    PubMed

    John, G C; Nduati, R W; Mbori-Ngacha, D; Overbaugh, J; Welch, M; Richardson, B A; Ndinya-Achola, J; Bwayo, J; Krieger, J; Onyango, F; Kreiss, J K

    1997-01-01

    The presence of human immunodeficiency virus type 1 (HIV-1) in genital secretions may be a determinant of vertical HIV-1 transmission. Cervical and vaginal secretions from HIV-1-seropositive pregnant women were evaluated to determine prevalence and correlates of HIV-1-infected cells in the genital tract. HIV-1 DNA was detected by polymerase chain reaction in 32% of 212 cervical and 10% of 215 vaginal specimens. Presence of HIV-1 DNA in the cervix was associated with cervical mucopus and a significantly lower absolute CD4 cell count (354 vs. 469, P < .001). An absolute CD4 cell count <200 was associated with a 9.6-fold increased odds of cervical HIV-1 DNA detection compared with a count > or = 500 (95% confidence interval, 2.8-34.2). Detection of vaginal HIV- 1 DNA was associated with abnormal vaginal discharge, lower absolute CD4 cell count, and severe vitamin A deficiency. Presence of HIV-1-infected cells in genital secretions was associated with immunosuppression and abnormal cervical or vaginal discharge.

  20. Detection of asymmetric blotches (asymmetric structureless areas) in dermoscopy images of malignant melanoma using relative color

    PubMed Central

    Stoecker, William V.; Gupta, Kapil; Stanley, R. Joe; Moss, Randy H.; Shrestha, Bijaya

    2011-01-01

    Background Dermoscopy, also known as dermatoscopy or epiluminescence microscopy (ELM), is a non-invasive, in vivo technique, which permits visualization of features of pigmented melanocytic neoplasms that are not discernable by examination with the naked eye. One prominent feature useful for melanoma detection in dermoscopy images is the asymmetric blotch (asymmetric structureless area). Method Using both relative and absolute colors, blotches are detected in this research automatically by using thresholds in the red and green color planes. Several blotch indices are computed, including the scaled distance between the largest blotch centroid and the lesion centroid, ratio of total blotch areas to lesion area, ratio of largest blotch area to lesion area, total number of blotches, size of largest blotch, and irregularity of largest blotch. Results The effectiveness of the absolute and relative color blotch features was examined for melanoma/benign lesion discrimination over a dermoscopy image set containing 165 melanomas (151 invasive melanomas and 14 melanomas in situ) and 347 benign lesions (124 nevocellular nevi without dysplasia and 223 dysplastic nevi) using a leave-one-out neural network approach. Receiver operating characteristic curve results are shown, highlighting the sensitivity and specificity of melanoma detection. Statistical analysis of the blotch features are also presented. Conclusion Neural network and statistical analysis showed that the blotch detection method was somewhat more effective using relative color than using absolute color. The relative-color blotch detection method gave a diagnostic accuracy of about 77%. PMID:15998328

  1. The current status of the Gas Electron Multiplier (GEM) research at Kasetsart University, Thailand

    NASA Astrophysics Data System (ADS)

    Kumpiranon, P.; Kulasri, K.; Rittirong, A.; Saenboonruang, K.

    2017-06-01

    During the past decade, Gas Electron Multiplier (GEM) detectors have been greatly developed and utilized in numbers of applications including advanced nuclear and particle researches, medical imaging, astrophysics, and neutron detection for national security. Our GEM research group at the Department of Applied Radiation and Isotopes, Faculty of Science, Kasetsart University, Thailand, realized in its excellent properties/potentials and started extensive researches on GEM detectors. To build a strong foundation on our research group, two 10 cm × 10 cm triple GEM detectors were characterized on their important properties including absolute gains and detection uniformity. Moreover, to widen applications of the GEM detector, our group had modified the GEM detector by introducing either solid or gaseous neutron converters to the detector so that the detector could effectively detect neutrons. These modifications included coating a thin film of 10B and natB to the GEM drift cathode for thermal neutron detection and flowing a gas mixture of He/CO2 (80:20 and 70:30) and C4H10/He/CO2 (7:70:23) for fast neutron detection. Results showed that the modified GEM-based neutron detector could detect both types of neutrons with different relative efficiencies and gains depending on thicknesses and types of neutron converters. This article discusses basic knowledge of the GEM detector, construction and testing procedures, results, and discussion.

  2. Two-dimensional fluorescence-detected coherent spectroscopy with absolute phasing by confocal imaging of a dynamic grating and 27-step phase-cycling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De, Arijit K., E-mail: akde@lbl.gov; Fleming, Graham R., E-mail: grfleming@lbl.gov; Department of Chemistry, University of California at Berkeley, Berkeley, California 94702

    2014-05-21

    We present a novel experimental scheme for two-dimensional fluorescence-detected coherent spectroscopy (2D-FDCS) using a non-collinear beam geometry with the aid of “confocal imaging” of dynamic (population) grating and 27-step phase-cycling to extract the signal. This arrangement obviates the need for distinct experimental designs for previously developed transmission detected non-collinear two-dimensional coherent spectroscopy (2D-CS) and collinear 2D-FDCS. We also describe a novel method for absolute phasing of the 2D spectrum. We apply this method to record 2D spectra of a fluorescent dye in solution at room temperature and observe “spectral diffusion.”.

  3. Advanced capabilities and applications of a sputter-RBS system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brijs, B.; Deleu, J.; Beyer, G.

    1999-06-10

    In previous experiments, sputter-RBS{sup 1} has proven to be an ideal tool to study the interaction of low energy ions. This contribution employs the same methodology to identify surface contamination induced during sputtering and to the determine absolute sputter yields. In the first experiment ERDA analysis was used to study the evolution of Hydrogen contamination during sputter-RBS experiments. Since the determination of Hydrogen concentration in very thin near surface layers is frequently limited by the presence of a strong surface peak of Hydrogen originating from adsorbed contamination of the residual vacuum, removal of this contamination would increase the sensitivity formore » Hydrogen detection in the near sub surface drastically. Therefore low energy (12 keV) Argon sputtering was used to remove the Hydrogen surface peak. However enhanced Hydrogen adsorption was observed related to the Ar dose. This experiment shows that severe vacuum conditions and the use of high current densities/sputter yields are a prerequisite for an efficient detection of Hydrogen in the near surface layers. In the second experiment, an attempt was made to determine the sputter yield of Cu during low energy (12 keV) Oxygen bombardment. In order to determine the accumulated dose of the low energy ion beam, a separate Faraday cup in combination with a remote controlled current have been added to the existing sputter-RBS set-up. Alternating sputtering and RBS analysis seem to be an adequate tool for the determination of the absolute sputter yield of Cu and this as well in the as under steady state conditions.« less

  4. Improvement of correlation-based centroiding methods for point source Shack-Hartmann wavefront sensor

    NASA Astrophysics Data System (ADS)

    Li, Xuxu; Li, Xinyang; wang, Caixia

    2018-03-01

    This paper proposes an efficient approach to decrease the computational costs of correlation-based centroiding methods used for point source Shack-Hartmann wavefront sensors. Four typical similarity functions have been compared, i.e. the absolute difference function (ADF), ADF square (ADF2), square difference function (SDF), and cross-correlation function (CCF) using the Gaussian spot model. By combining them with fast search algorithms, such as three-step search (TSS), two-dimensional logarithmic search (TDL), cross search (CS), and orthogonal search (OS), computational costs can be reduced drastically without affecting the accuracy of centroid detection. Specifically, OS reduces calculation consumption by 90%. A comprehensive simulation indicates that CCF exhibits a better performance than other functions under various light-level conditions. Besides, the effectiveness of fast search algorithms has been verified.

  5. An Efficient Semi-fragile Watermarking Scheme for Tamper Localization and Recovery

    NASA Astrophysics Data System (ADS)

    Hou, Xiang; Yang, Hui; Min, Lianquan

    2018-03-01

    To solve the problem that remote sensing images are vulnerable to be tampered, a semi-fragile watermarking scheme was proposed. Binary random matrix was used as the authentication watermark, which was embedded by quantizing the maximum absolute value of directional sub-bands coefficients. The average gray level of every non-overlapping 4×4 block was adopted as the recovery watermark, which was embedded in the least significant bit. Watermarking detection could be done directly without resorting to the original images. Experimental results showed our method was robust against rational distortions to a certain extent. At the same time, it was fragile to malicious manipulation, and realized accurate localization and approximate recovery of the tampered regions. Therefore, this scheme can protect the security of remote sensing image effectively.

  6. SIX MORE QUASARS AT REDSHIFT 6 DISCOVERED BY THE CANADA-FRANCE HIGH-z QUASAR SURVEY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willott, Chris J.; Crampton, David; Hutchings, John B.

    2009-03-15

    We present imaging and spectroscopic observations for six quasars at z {>=} 5.9 discovered by the Canada-France High-z Quasar Survey (CFHQS). The CFHQS contains subsurveys with a range of flux and area combinations to sample a wide range of quasar luminosities at z {approx} 6. The new quasars have luminosities 10-75 times lower than the most luminous Sloan Digital Sky Survey quasars at this redshift. The least luminous quasar, CFHQS J0216-0455 at z = 6.01, has absolute magnitude M {sub 1450} = -22.21, well below the likely break in the luminosity function. This quasar is not detected in a deepmore » XMM-Newton survey showing that optical selection is still a very efficient tool for finding high-redshift quasars.« less

  7. Overcoming interference with the detection of a stable isotopically labeled microtracer in the evaluation of beclabuvir absolute bioavailability using a concomitant microtracer approach.

    PubMed

    Jiang, Hao; Titsch, Craig; Zeng, Jianing; Jones, Barry; Joyce, Philip; Gandhi, Yash; Turley, Wesley; Burrell, Richard; Aubry, Anne F; Arnold, Mark E

    2017-09-05

    The oral absolute bioavailability of beclabuvir in healthy subjects was determined using a microdose (100μg) of the stable isotopically labeled tracer via intravenous (IV) infusion started after oral dosing of beclabuvir (150mg). To simultaneously analyze the concentrations of the IV microtracer ([ 13 C 6 ]beclabuvir) and beclabuvir in plasma samples, a liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) method was initially developed. Surprisingly beclabuvir significantly interfered with the IV microtracer detection when using the selected reaction monitoring (SRM) in the assay. An interfering component from the drug substance was observed using a high resolution mass spectrometer (HRMS). The mass-to-charge (m/z) of the interfering component was -32ppm different from the nominal value for the IV microtracer and thus could not be differentiated in the SRM assay by the unit mass resolution. To overcome this interference, we evaluated two approaches by either monitoring an alternative product ion using the SRM assay or isolating the interfering component using the parallel reaction monitoring (PRM) assay on the HRMS. This case study has demonstrated two practical approaches for overcoming interferences with the detection of stable isotopically labeled IV microtracers in the evaluation of absolute bioavailability, which provides users the flexibility in using either LC-MS/MS or HRMS to mitigate unpredicted interferences in the assay to support microtracer absolute bioavailability studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Costas loop lock detection in the advanced receiver

    NASA Technical Reports Server (NTRS)

    Mileant, A.; Hinedi, S.

    1989-01-01

    The advanced receiver currently being developed uses a Costas digital loop to demodulate the subcarrier. Previous analyses of lock detector algorithms for Costas loops have ignored the effects of the inherent correlation between the samples of the phase-error process. Accounting for this correlation is necessary to achieve the desired lock-detection probability for a given false-alarm rate. Both analysis and simulations are used to quantify the effects of phase correlation on lock detection for the square-law and the absolute-value type detectors. Results are obtained which depict the lock-detection probability as a function of loop signal-to-noise ratio for a given false-alarm rate. The mathematical model and computer simulation show that the square-law detector experiences less degradation due to phase jitter than the absolute-value detector and that the degradation in detector signal-to-noise ratio is more pronounced for square-wave than for sine-wave signals.

  9. Theoretical considerations on the optogalvanic detection of laser induced fluorescence in atmospheric pressure atomizers

    NASA Astrophysics Data System (ADS)

    Omenetto, N.; Smith, B. W.; Winefordner, J. D.

    1989-01-01

    Several theoretical considerations are given on the potential and practical capabilities of a detector of fluorescence radiation whose operating principle is based on a multi-step excitation-ionization scheme involving the fluorescence photons as the first excitation step. This detection technique, which was first proposed by MATVEEVet al. [ Zh. Anal Khim.34, 846 (1979)], combines two independent atomizers, one analytical cell for the excitation of the sample fluorescence and one cell, filled with pure analyte atomic vapor, acting as the ionization detector. One laser beam excites the analyte fluorescence in the analytical cell and one (or two) laser beams are used to ionize the excited atoms in the detector. Several different causes of signal and noise are evaluated, together with a discussion on possible analytical atom reservoirs (flames, furnaces) and laser sources which could be used with this approach. For properly devised conditions, i.e. optical saturation of the fluorescence and unity ionization efficiency, detection limits well below pg/ml in solution and well below femtograms as absolute amounts in furnaces can be predicted. However, scattering problems, which are absent in a conventional laser-enhanced ionization set-up, may be important in this approach.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karpius, Peter Joseph; Myers, Steven Charles

    This presentation is a part of the DHS LSS spectroscopy course and provides an overview of the following concepts: detector system components, intrinsic and absolute efficiency, resolution and linearity, and operational issues and limits.

  11. Laser Truss Sensor for Segmented Telescope Phasing

    NASA Technical Reports Server (NTRS)

    Liu, Duncan T.; Lay, Oliver P.; Azizi, Alireza; Erlig, Herman; Dorsky, Leonard I.; Asbury, Cheryl G.; Zhao, Feng

    2011-01-01

    A paper describes the laser truss sensor (LTS) for detecting piston motion between two adjacent telescope segment edges. LTS is formed by two point-to-point laser metrology gauges in a crossed geometry. A high-resolution (<30 nm) LTS can be implemented with existing laser metrology gauges. The distance change between the reference plane and the target plane is measured as a function of the phase change between the reference and target beams. To ease the bandwidth requirements for phase detection electronics (or phase meter), homodyne or heterodyne detection techniques have been used. The phase of the target beam also changes with the refractive index of air, which changes with the air pressure, temperature, and humidity. This error can be minimized by enclosing the metrology beams in baffles. For longer-term (weeks) tracking at the micron level accuracy, the same gauge can be operated in the absolute metrology mode with an accuracy of microns; to implement absolute metrology, two laser frequencies will be used on the same gauge. Absolute metrology using heterodyne laser gauges is a demonstrated technology. Complexity of laser source fiber distribution can be optimized using the range-gated metrology (RGM) approach.

  12. Genital Shedding of Human Immunodeficiency Virus Type 1 DNA during Pregnancy: Association with Immunosuppression, Abnormal Cervical or Vaginal Discharge, and Severe Vitamin A Deficiency

    PubMed Central

    John, Grace C.; Nduati, Ruth W.; Mbori-Ngacha, Dorothy; Overbaugh, Julie; Welch, Mary; Richardson, Barbra A.; Ndinya-Achola, Jeckoniah; Bwayo, Job; Krieger, John; Onyango, Francis; Kreiss, Joan K.

    2012-01-01

    The presence of human immunodeficiency virus type 1 (HIV-1) in genital secretions may be a determinant of vertical HIV-1 transmission. Cervical and vaginal secretions from HIV-1–seropositive pregnant women were evaluated to determine prevalence and correlates of HIV-1–infected cells in the genital tract. HIV-1 DNA was detected by polymerase chain reaction in 32% of 212 cervical and 10% of 215 vaginal specimens. Presence of HIV-1 DNA in the cervix was associated with cervical mucopus and a significantly lower absolute CD4 cell count (354 vs. 469, P < .001). An absolute CD4 cell count <200 was associated with a 9.6-fold increased odds of cervical HIV-1 DNA detection compared with a count ≥500 (95% confidence interval, 2.8–34.2). Detection of vaginal HIV-1 DNA was associated with abnormal vaginal discharge, lower absolute CD4 cell count, and severe vitamin A deficiency. Presence of HIV-1–infected cells in genital secretions was associated with immunosuppression and abnormal cervical or vaginal discharge. PMID:8985196

  13. Detection of radioactive particles offshore by γ-ray spectrometry Part I: Monte Carlo assessment of detection depth limits

    NASA Astrophysics Data System (ADS)

    Maučec, M.; de Meijer, R. J.; Rigollet, C.; Hendriks, P. H. G. M.; Jones, D. G.

    2004-06-01

    A joint research project between the British Geological Survey and Nuclear Geophysics Division of the Kernfysisch Versneller Instituut, Groningen, the Netherlands, was commissioned by the United Kingdom Atomic Energy Authority to establish the efficiency of a towed seabed γ-ray spectrometer for the detection of 137Cs-containing radioactive particles offshore Dounreay, Scotland. Using the MCNP code, a comprehensive Monte Carlo feasibility study was carried out to model various combinations of geological matrices, particle burial depth and lateral displacement, source activity and detector material. To validate the sampling and absolute normalisation procedures of MCNP for geometries including multiple (natural and induced) heterogeneous sources in environmental monitoring, a benchmark experiment was conducted. The study demonstrates the ability of seabed γ-ray spectrometry to locate radioactive particles offshore and to distinguish between γ count rate increases due to particles from those due to enhanced natural radioactivity. The information presented in this study will be beneficial for estimation of the inventory of 137Cs particles and their activity distribution and for the recovery of particles from the sea floor. In this paper, the Monte Carlo assessment of the detection limits is presented. The estimation of the required towing speed and acquisition times and their application to radioactive particle detection and discrimination offshore formed a supplementary part of this study.

  14. Simultaneous separation and detection of actinides in acidic solutions using an extractive scintillating resin.

    PubMed

    Roane, J E; DeVol, T A

    2002-11-01

    An extractive scintillating resin was evaluated for the simultaneous separation and detection of actinides in acidic solutions. The transuranic extractive scintillating (TRU-ES) resin is composed of an inert macroporous polystyrene core impregnated with organic fluors (diphenyloxazole and 1,4-bis-(4-methyl-5-phenyl-2-oxazolyl)benzene) and an extractant (octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide in tributyl phosphate). The TRU-ES resin was packed into FEP Teflon tubing to produce a flow cell (0.2-mL free column volume), which is placed into a scintillation detection system to obtain pulse height spectra and time series data during loading and elution of actinides onto/from the resin. The alpha-particle absolute detection efficiencies ranged from 77% to 96.5%, depending on the alpha energy and quench. In addition to the on-line analyses, off-line analyses of the effluent can be conducted using conventional detection methods. The TRU-ES resin was applied to the quantification of a mixed radionuclide solution and two actual waste samples. The on-line characterization of the mixed radionuclide solution was within 10% of the reported activities whereas the agreement with the waste samples was not as good due to sorption onto the sample container walls and the oxidation state of plutonium. Agreement between the on-line and off-line analyses was within 35% of one another for both waste samples.

  15. Reprint of "Two-stage sparse coding of region covariance via Log-Euclidean kernels to detect saliency".

    PubMed

    Zhang, Ying-Ying; Yang, Cai; Zhang, Ping

    2017-08-01

    In this paper, we present a novel bottom-up saliency detection algorithm from the perspective of covariance matrices on a Riemannian manifold. Each superpixel is described by a region covariance matrix on Riemannian Manifolds. We carry out a two-stage sparse coding scheme via Log-Euclidean kernels to extract salient objects efficiently. In the first stage, given background dictionary on image borders, sparse coding of each region covariance via Log-Euclidean kernels is performed. The reconstruction error on the background dictionary is regarded as the initial saliency of each superpixel. In the second stage, an improvement of the initial result is achieved by calculating reconstruction errors of the superpixels on foreground dictionary, which is extracted from the first stage saliency map. The sparse coding in the second stage is similar to the first stage, but is able to effectively highlight the salient objects uniformly from the background. Finally, three post-processing methods-highlight-inhibition function, context-based saliency weighting, and the graph cut-are adopted to further refine the saliency map. Experiments on four public benchmark datasets show that the proposed algorithm outperforms the state-of-the-art methods in terms of precision, recall and mean absolute error, and demonstrate the robustness and efficiency of the proposed method. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Evaluation of a multiarray system for pharmaceutical analysis by microemulsion electrokinetic chromatography.

    PubMed

    Lynen, Frederic; Saavedra, Luis; Saveedra, Luis; Nickerson, Beverly; Sandra, Pat

    2011-05-15

    A multiplexed capillary electrophoresis (CE) system equipped with 96 channels was evaluated for high-throughput screening in drug discovery by microemulsion electrokinetic chromatography (MEEKC). Method transfer from a single channel to a multichannel CE system is described. Loss of efficiency and reduced migration times could be elucidated to the poor efficacy in Joule heat dissipation by forced air cooling in the multiarray system compared to liquid cooling in the single channel instrument. On the other hand, only 48 channels could actually be used because of the maximum total current of 3 mA. Precision data remained below 8% and 9% for migration times and peak areas, respectively. Some UV-detector cross-talk interference between neighboring capillary channels was noted. Impurities at 0.5% compared to the main peak (100%) could be detected with the multiplexed system which is 10 times lower compared to the single capillary system. Higher efficiency and improved figures of merit (absolute sensitivity and no cross-talk interferences) were obtained by using an array of only 24 capillaries. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Comparison of Two Methods for Detecting Alternative Splice Variants Using GeneChip® Exon Arrays

    PubMed Central

    Fan, Wenhong; Stirewalt, Derek L.; Radich, Jerald P.; Zhao, Lueping

    2011-01-01

    The Affymetrix GeneChip Exon Array can be used to detect alternative splice variants. Microarray Detection of Alternative Splicing (MIDAS) and Partek® Genomics Suite (Partek® GS) are among the most popular analytical methods used to analyze exon array data. While both methods utilize statistical significance for testing, MIDAS and Partek® GS could produce somewhat different results due to different underlying assumptions. Comparing MIDAS and Partek® GS is quite difficult due to their substantially different mathematical formulations and assumptions regarding alternative splice variants. For meaningful comparison, we have used the previously published generalized probe model (GPM) which encompasses both MIDAS and Partek® GS under different assumptions. We analyzed a colon cancer exon array data set using MIDAS, Partek® GS and GPM. MIDAS and Partek® GS produced quite different sets of genes that are considered to have alternative splice variants. Further, we found that GPM produced results similar to MIDAS as well as to Partek® GS under their respective assumptions. Within the GPM, we show how discoveries relating to alternative variants can be quite different due to different assumptions. MIDAS focuses on relative changes in expression values across different exons within genes and tends to be robust but less efficient. Partek® GS, however, uses absolute expression values of individual exons within genes and tends to be more efficient but more sensitive to the presence of outliers. From our observations, we conclude that MIDAS and Partek® GS produce complementary results, and discoveries from both analyses should be considered. PMID:23675234

  18. Pharmaceutical container/closure integrity. I: Mass spectrometry-based helium leak rate detection for rubber-stoppered glass vials.

    PubMed

    Kirsch, L E; Nguyen, L; Moeckly, C S

    1997-01-01

    The development of mass spectrometry-based leak detection for pharmaceutical container integrity was undertaken to provide an alternative to microbial challenge testing. Standard 10-mL vials were modified to contain pinholes (0.5 to 10 microns) by affixing micropipettes with epoxy into 2-mm vial side wall holes. The absolute leak rate was determined using vials that were sealed in a tracer (helium) environment with butyl rubber stoppers and crimps. Alternatively leak rates were determined using vials that were sealed in room air and exposed to tracer under pressure (charging or bombing). Tracer leak rates were measured with mass spectrometry leak rate detectors. The absolute leak rate was correlated the squared nominal leak radius which suggested that the mode of gas flow through the glass pipette leaks was more turbulent than viscous even at low leak rates typically associated with viscous flow. The minimum observed absolute leak rate was about 10(-6.6) std cc/sec and was likely due to helium permeation through the rubber stoppers. Heat-stressed rubber stoppers did not affect the baseline absolute leak rate. Adsorption of helium tracer to the test unit surfaces was found to confound baseline leak rate measurement reliability but was eliminated as a source of variation by exposing the test units to ambient air for > or = 12 hours. The absolute leak rate and the leak rate measured after charging were related in a mathematically predictable way.

  19. Anomalies in the detection of change: When changes in sample size are mistaken for changes in proportions.

    PubMed

    Fiedler, Klaus; Kareev, Yaakov; Avrahami, Judith; Beier, Susanne; Kutzner, Florian; Hütter, Mandy

    2016-01-01

    Detecting changes, in performance, sales, markets, risks, social relations, or public opinions, constitutes an important adaptive function. In a sequential paradigm devised to investigate detection of change, every trial provides a sample of binary outcomes (e.g., correct vs. incorrect student responses). Participants have to decide whether the proportion of a focal feature (e.g., correct responses) in the population from which the sample is drawn has decreased, remained constant, or increased. Strong and persistent anomalies in change detection arise when changes in proportional quantities vary orthogonally to changes in absolute sample size. Proportional increases are readily detected and nonchanges are erroneously perceived as increases when absolute sample size increases. Conversely, decreasing sample size facilitates the correct detection of proportional decreases and the erroneous perception of nonchanges as decreases. These anomalies are however confined to experienced samples of elementary raw events from which proportions have to be inferred inductively. They disappear when sample proportions are described as percentages in a normalized probability format. To explain these challenging findings, it is essential to understand the inductive-learning constraints imposed on decisions from experience.

  20. Electromagnetic waves with frequencies near the local proton gyrofrequency: ISEE-3 1 AU observations

    NASA Technical Reports Server (NTRS)

    Tsurutani, Bruce T.; Arballo, John K.; Mok, John; Smith, Edward J.; Mason, Glenn M.; Tan, Lun C.

    1994-01-01

    Low Frequency (LF) electromagnetic waves with periods near the local proton gyrofrequency have been detected in interplanetary space by the magnetometer onboard International-Sun-Earth-Explorer-3 (ISEE-3). Transverse peak-to-peak amplitudes as large as delta vector B/absolute value of B approximately 0.4 have been noted with compressional components (Delta absolute value of B/absolute value of B) typically less than or = 0.1. Generally, the waves have even smaller amplitudes, or are not detectable within the solar wind turbulence. The waves are elliptically/linearly polarized and are often, but not always, found to propagate nearly along vector B(sub zero). Both right- and left-hand polarizations in the spacecraft-frame have been detected. The waves are observed during all orientations of the interplanetary magnetic field, with the Parker spiral orientation being the most common case. Because the waves are detected at and near the local proton cyclotron frequency, the generation mechanism must almost certainly be solar wind pickup of freshly created hydrogen ions. Possible sources for the hydrogen are the Earth's atmosphere, coronal mass ejections from the Sun, comets and interstellar neutral atoms. At this time it is not obvious which potential source is the correct one. Statistical tests employing over one year of ISEE-3 data will be done in the near future to eliminate/confirm some of these possibilities.

  1. An efficient robust sound classification algorithm for hearing aids.

    PubMed

    Nordqvist, Peter; Leijon, Arne

    2004-06-01

    An efficient robust sound classification algorithm based on hidden Markov models is presented. The system would enable a hearing aid to automatically change its behavior for differing listening environments according to the user's preferences. This work attempts to distinguish between three listening environment categories: speech in traffic noise, speech in babble, and clean speech, regardless of the signal-to-noise ratio. The classifier uses only the modulation characteristics of the signal. The classifier ignores the absolute sound pressure level and the absolute spectrum shape, resulting in an algorithm that is robust against irrelevant acoustic variations. The measured classification hit rate was 96.7%-99.5% when the classifier was tested with sounds representing one of the three environment categories included in the classifier. False-alarm rates were 0.2%-1.7% in these tests. The algorithm is robust and efficient and consumes a small amount of instructions and memory. It is fully possible to implement the classifier in a DSP-based hearing instrument.

  2. Healthy live birth using theophylline in a case of retrograde ejaculation and absolute asthenozoospermia.

    PubMed

    Ebner, Thomas; Shebl, Omar; Mayer, Richard Bernhard; Moser, Marianne; Costamoling, Walter; Oppelt, Peter

    2014-02-01

    To analyze whether the use of ready-to-use theophylline is a feasible option in a case of retrograde ejaculation and absolute asthenozoospermia. Case report. In vitro fertilization unit of a public hospital. Thirty-one-year-old nulliparous woman, and 39-year-old male with retrograde ejaculation and absolute asthenozoospermia. Retrieval of postejaculatory urine, restoration of motility using a methylxanthine, intracytoplasmic sperm injection, single-embryo transfer. Sperm motility, fertilization, embryo quality, live birth. Successful fertilization and a single-embryo transfer resulted in a healthy live birth. Theophylline turned out to be a safe, efficient agent for stimulating immotile spermatozoa in patients with retrograde ejaculation. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  3. How efficient is sliding-scale insulin therapy? Problems with a 'cookbook' approach in hospitalized patients.

    PubMed

    Katz, C M

    1991-04-01

    Sliding-scale insulin therapy is seldom the best way to treat hospitalized diabetic patients. In the few clinical situations in which it is appropriate, close attention to details and solidly based scientific principles is absolutely necessary. Well-organized alternative approaches to insulin therapy usually offer greater efficiency and effectiveness.

  4. The World Bank’s Clean Technology Fund (CTF)

    DTIC Science & Technology

    2008-11-24

    economies such as China and India. The incremental carbon dioxide (CO2) emissions from China and India alone have accounted for an estimated 62% of new...gas reductions. Carbon dioxide emissions from power plants are directly proportional to efficiency, so a plant going with an 18% absolute increase in...efficiency would produce 18% less carbon dioxide . These are the higher heating value (HHV) thermal efficiency rates, not be confused with lower heating

  5. Fluorescent probes and bioimaging: alkali metals, alkaline earth metals and pH.

    PubMed

    Yin, Jun; Hu, Ying; Yoon, Juyoung

    2015-07-21

    All living species and life forms have an absolute requirement for bio-functional metals and acid-base equilibrium chemistry owing to the critical roles they play in biological processes. Hence, a great need exists for efficient methods to detect and monitor biometals and acids. In the last few years, great attention has been paid to the development of organic molecule based fluorescent chemosensors. The availability of new synthetic fluorescent probes has made fluorescence microscopy an indispensable tool for tracing biologically important molecules and in the area of clinical diagnostics. This review highlights the recent advances that have been made in the design and bioimaging applications of fluorescent probes for alkali metals and alkaline earth metal cations, including lithium, sodium and potassium, magnesium and calcium, and for pH determination within biological systems.

  6. Laser-based sensors for oil spill remote sensing

    NASA Astrophysics Data System (ADS)

    Brown, Carl E.; Fingas, Mervin F.; Mullin, Joseph V.

    1997-07-01

    Remote sensing is becoming an increasingly important tool for the effective direction of oil spill countermeasures. Cleanup personnel have recognized that remote sensing can increase spill cleanup efficiency. It has long been recognized that there is no one sensor which is capable of detecting oil and related petroleum products in all environments and spill scenarios. There are sensors which possess a wide field-of- view and can therefore be used to map the overall extent of the spill. These sensors, however lack the capability to positively identify oil and related products, especially along complicated beach and shoreline environments where several substrates are present. The laser-based sensors under development by the Emergencies Science Division of Environment Canada are designed to fill specific roles in oil spill response. The scanning laser environmental airborne fluorosensor (SLEAF) is being developed to detect and map oil and related petroleum products in complex marine and shoreline environments where other non-specific sensors experience difficulty. The role of the SLEAF would be to confirm or reject suspected oil contamination sites that have been targeted by the non-specific sensors. This confirmation will release response crews from the time-consuming task of physically inspecting each site, and direct crews to sites that require remediation. The laser ultrasonic remote sensing of oil thickness (LURSOT) sensor will provide an absolute measurement of oil thickness from an airborne platform. There are presently no sensors available, either airborne or in the laboratory which can provide an absolute measurement of oil thickness. This information is necessary for the effective direction of spill countermeasures such as dispersant application and in-situ burning. This paper describes the development of laser-based airborne oil spill remote sensing instrumentation at Environment Canada and identifies the anticipated benefits of the use of this technology to the oil spill response community.

  7. A method for quantitative analysis of standard and high-throughput qPCR expression data based on input sample quantity.

    PubMed

    Adamski, Mateusz G; Gumann, Patryk; Baird, Alison E

    2014-01-01

    Over the past decade rapid advances have occurred in the understanding of RNA expression and its regulation. Quantitative polymerase chain reactions (qPCR) have become the gold standard for quantifying gene expression. Microfluidic next generation, high throughput qPCR now permits the detection of transcript copy number in thousands of reactions simultaneously, dramatically increasing the sensitivity over standard qPCR. Here we present a gene expression analysis method applicable to both standard polymerase chain reactions (qPCR) and high throughput qPCR. This technique is adjusted to the input sample quantity (e.g., the number of cells) and is independent of control gene expression. It is efficiency-corrected and with the use of a universal reference sample (commercial complementary DNA (cDNA)) permits the normalization of results between different batches and between different instruments--regardless of potential differences in transcript amplification efficiency. Modifications of the input quantity method include (1) the achievement of absolute quantification and (2) a non-efficiency corrected analysis. When compared to other commonly used algorithms the input quantity method proved to be valid. This method is of particular value for clinical studies of whole blood and circulating leukocytes where cell counts are readily available.

  8. Upconverting fluorescent nanoparticles for biodetection and photoactivation

    NASA Astrophysics Data System (ADS)

    Huang, Kai; Li, WenKai; Jayakumar, Muthu Kumara Gnanasammandhan; Zhang, Yong

    2013-03-01

    Fluorophores including fluorescent dyes/proteins and quantum dots (QDs) are used for fluorescence-based imaging and detection. These are based on `downconversion fluorescence' and have several drawbacks: photobleaching, autofluorescence, short tissue penetration depth and tissue photo-damage. Upconversion fluorescent nanoparticles (UCNs) emit detectable photons of higher energy in the short wavelength range upon irradiation with near-infrared (NIR) light based on a process termed `upconversion'. UCNs show absolute photostability, negligible autofluorescence, high penetration depth and minimum photodamage to biological tissues. Lanthanide doped nanocrystals with nearinfrared NIR-to-NIR and/or NIR-to-VIS and/or NIR-to-UV upconversion fluorescence emission have been synthesized. The nanocrystals with small size and tunable multi-color emission have been developed. The emission can be tuned by doping different upconverting lanthanide ions into the nanocrystals. The nanocrystals with core-shell structure have also been prepared to tune the emission color. The surfaces of these nanocrystals have been modified to render them water dispersible and biocompatible. They can be used for ultrasensitive interference-free biodetection because most biomolecules do not have upconversion properties. UCNs are also useful for light based therapy with enhanced efficiency, for example, photoactivation.

  9. Cost-effectiveness of follow-up of pulmonary nodules incidentally detected on cardiac computed tomographic angiography in patients with suspected coronary artery disease.

    PubMed

    Goehler, Alexander; McMahon, Pamela M; Lumish, Heidi S; Wu, Carol C; Munshi, Vidit; Gilmore, Michael; Chung, Jonathan H; Ghoshhajra, Brian B; Mark, Daniel; Truong, Quynh A; Gazelle, G Scott; Hoffmann, Udo

    2014-08-19

    Pulmonary nodules (PNs) are often detected incidentally during coronary computed tomographic (CT) angiography, which is increasingly being used to evaluate patients with chest pain symptoms. However, the efficiency of following up on incidentally detected PN is unknown. We determined demographic and clinical characteristics of stable symptomatic patients referred for coronary CT angiography in whom incidentally detected PNs warranted follow-up. A validated lung cancer simulation model was populated with data from these patients, and clinical and economic consequences of follow-up per Fleischner guidelines versus no follow-up were simulated. Of the 3665 patients referred for coronary CT angiography, 591 (16%) had PNs requiring follow-up. The mean age of patients with PNs was 59±10 years; 66% were male; 67% had ever smoked; and 21% had obstructive coronary artery disease. The projected overall lung cancer incidence was 5.8% in these patients, but the majority died of coronary artery disease (38%) and other causes (57%). Follow-up of PNs was associated with a 4.6% relative reduction in cumulative lung cancer mortality (absolute mortality: follow-up, 4.33% versus non-follow-up, 4.54%), more downstream testing (follow-up, 2.34 CTs per patient versus non-follow-up, 1.01 CTs per patient), and an average increase in quality-adjusted life of 7 days. Costs per quality-adjusted life-year gained were $154 700 to follow up the entire cohort and $129 800 per quality-adjusted life-year when only smokers were included. Follow-up of PNs incidentally detected in patients undergoing coronary CT angiography for chest pain evaluation is associated with a small reduction in lung cancer mortality. However, significant downstream testing contributes to limited efficiency, as demonstrated by a high cost per quality-adjusted life-year, especially in nonsmokers. © 2014 American Heart Association, Inc.

  10. BEAMing LAMP: single-molecule capture and on-bead isothermal amplification for digital detection of hepatitis C virus in plasma.

    PubMed

    Chen, Jiyun; Xu, Xiaomin; Huang, Zhimei; Luo, Yuan; Tang, Lijuan; Jiang, Jian-Hui

    2018-01-02

    A novel dNAD platform (BEAMing LAMP) by combining emulsion micro-reactors, single-molecule magnetic capture and on-bead loop-mediated isothermal amplification has been developed for DNA detection, which enables absolute and high-precision quantification of a target with a detection limit of 300 copies.

  11. Instrument for Real-Time Digital Nucleic Acid Amplification on Custom Microfluidic Devices

    PubMed Central

    Selck, David A.

    2016-01-01

    Nucleic acid amplification tests that are coupled with a digital readout enable the absolute quantification of single molecules, even at ultralow concentrations. Digital methods are robust, versatile and compatible with many amplification chemistries including isothermal amplification, making them particularly invaluable to assays that require sensitive detection, such as the quantification of viral load in occult infections or detection of sparse amounts of DNA from forensic samples. A number of microfluidic platforms are being developed for carrying out digital amplification. However, the mechanistic investigation and optimization of digital assays has been limited by the lack of real-time kinetic information about which factors affect the digital efficiency and analytical sensitivity of a reaction. Commercially available instruments that are capable of tracking digital reactions in real-time are restricted to only a small number of device types and sample-preparation strategies. Thus, most researchers who wish to develop, study, or optimize digital assays rely on the rate of the amplification reaction when performed in a bulk experiment, which is now recognized as an unreliable predictor of digital efficiency. To expand our ability to study how digital reactions proceed in real-time and enable us to optimize both the digital efficiency and analytical sensitivity of digital assays, we built a custom large-format digital real-time amplification instrument that can accommodate a wide variety of devices, amplification chemistries and sample-handling conditions. Herein, we validate this instrument, we provide detailed schematics that will enable others to build their own custom instruments, and we include a complete custom software suite to collect and analyze the data retrieved from the instrument. We believe assay optimizations enabled by this instrument will improve the current limits of nucleic acid detection and quantification, improving our fundamental understanding of single-molecule reactions and providing advancements in practical applications such as medical diagnostics, forensics and environmental sampling. PMID:27760148

  12. A false-alarm aware methodology to develop robust and efficient multi-scale infrared small target detection algorithm

    NASA Astrophysics Data System (ADS)

    Moradi, Saed; Moallem, Payman; Sabahi, Mohamad Farzan

    2018-03-01

    False alarm rate and detection rate are still two contradictory metrics for infrared small target detection in an infrared search and track system (IRST), despite the development of new detection algorithms. In certain circumstances, not detecting true targets is more tolerable than detecting false items as true targets. Hence, considering background clutter and detector noise as the sources of the false alarm in an IRST system, in this paper, a false alarm aware methodology is presented to reduce false alarm rate while the detection rate remains undegraded. To this end, advantages and disadvantages of each detection algorithm are investigated and the sources of the false alarms are determined. Two target detection algorithms having independent false alarm sources are chosen in a way that the disadvantages of the one algorithm can be compensated by the advantages of the other one. In this work, multi-scale average absolute gray difference (AAGD) and Laplacian of point spread function (LoPSF) are utilized as the cornerstones of the desired algorithm of the proposed methodology. After presenting a conceptual model for the desired algorithm, it is implemented through the most straightforward mechanism. The desired algorithm effectively suppresses background clutter and eliminates detector noise. Also, since the input images are processed through just four different scales, the desired algorithm has good capability for real-time implementation. Simulation results in term of signal to clutter ratio and background suppression factor on real and simulated images prove the effectiveness and the performance of the proposed methodology. Since the desired algorithm was developed based on independent false alarm sources, our proposed methodology is expandable to any pair of detection algorithms which have different false alarm sources.

  13. Efficient reversible data hiding in encrypted image with public key cryptosystem

    NASA Astrophysics Data System (ADS)

    Xiang, Shijun; Luo, Xinrong

    2017-12-01

    This paper proposes a new reversible data hiding scheme for encrypted images by using homomorphic and probabilistic properties of Paillier cryptosystem. The proposed method can embed additional data directly into encrypted image without any preprocessing operations on original image. By selecting two pixels as a group for encryption, data hider can retrieve the absolute differences of groups of two pixels by employing a modular multiplicative inverse method. Additional data can be embedded into encrypted image by shifting histogram of the absolute differences by using the homomorphic property in encrypted domain. On the receiver side, legal user can extract the marked histogram in encrypted domain in the same way as data hiding procedure. Then, the hidden data can be extracted from the marked histogram and the encrypted version of original image can be restored by using inverse histogram shifting operations. Besides, the marked absolute differences can be computed after decryption for extraction of additional data and restoration of original image. Compared with previous state-of-the-art works, the proposed scheme can effectively avoid preprocessing operations before encryption and can efficiently embed and extract data in encrypted domain. The experiments on the standard image files also certify the effectiveness of the proposed scheme.

  14. 49 CFR 214.337 - On-track safety procedures for lone workers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...

  15. 49 CFR 214.337 - On-track safety procedures for lone workers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...

  16. 49 CFR 214.337 - On-track safety procedures for lone workers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...

  17. 49 CFR 214.337 - On-track safety procedures for lone workers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...

  18. Comprehensive Panel of Real-Time TaqMan™ Polymerase Chain Reaction Assays for Detection and Absolute Quantification of Filoviruses, Arenaviruses, and New World Hantaviruses

    PubMed Central

    Trombley, Adrienne R.; Wachter, Leslie; Garrison, Jeffrey; Buckley-Beason, Valerie A.; Jahrling, Jordan; Hensley, Lisa E.; Schoepp, Randal J.; Norwood, David A.; Goba, Augustine; Fair, Joseph N.; Kulesh, David A.

    2010-01-01

    Viral hemorrhagic fever is caused by a diverse group of single-stranded, negative-sense or positive-sense RNA viruses belonging to the families Filoviridae (Ebola and Marburg), Arenaviridae (Lassa, Junin, Machupo, Sabia, and Guanarito), and Bunyaviridae (hantavirus). Disease characteristics in these families mark each with the potential to be used as a biological threat agent. Because other diseases have similar clinical symptoms, specific laboratory diagnostic tests are necessary to provide the differential diagnosis during outbreaks and for instituting acceptable quarantine procedures. We designed 48 TaqMan™-based polymerase chain reaction (PCR) assays for specific and absolute quantitative detection of multiple hemorrhagic fever viruses. Forty-six assays were determined to be virus-specific, and two were designated as pan assays for Marburg virus. The limit of detection for the assays ranged from 10 to 0.001 plaque-forming units (PFU)/PCR. Although these real-time hemorrhagic fever virus assays are qualitative (presence of target), they are also quantitative (measure a single DNA/RNA target sequence in an unknown sample and express the final results as an absolute value (e.g., viral load, PFUs, or copies/mL) on the basis of concentration of standard samples and can be used in viral load, vaccine, and antiviral drug studies. PMID:20439981

  19. Calibration and characterization of a highly efficient spectrometer in von Hamos geometry for 7-10 keV x-rays

    DOE PAGES

    Jarrott, L. C.; Wei, M. S.; McGuffey, C.; ...

    2017-04-27

    Here, we have built an absolutely calibrated, highly efficient, Bragg crystal spectrometer in von Hamos geometry. This zinc von Hamos spectrometer uses a crystal made from highly oriented pyrolytic graphite that is cylindrically bent along the non-dispersive axis. It is tuned to measure x-ray spectra in the 7–10 keV range and has been designed to be used on a Ten Inch Manipulator for the Omega and OmegaEP target chambers at the Laboratory for Laser Energetics in Rochester, USA. Significant shielding strategies and fluorescence mitigation have been implemented in addition to an imaging plate detector making it well suited for experimentsmore » in high-intensity environments. Here we present the design and absolute calibration as well as mosaicity and integrated reflectivity measurements.« less

  20. Sampling techniques for thrips (Thysanoptera: Thripidae) in preflowering tomato.

    PubMed

    Joost, P Houston; Riley, David G

    2004-08-01

    Sampling techniques for thrips (Thysanoptera: Thripidae) were compared in preflowering tomato plants at the Coastal Plain Experiment Station in Tifton, GA, in 2000 and 2003, to determine the most effective method of determining abundance of thrips on tomato foliage early in the growing season. Three relative sampling techniques, including a standard insect aspirator, a 946-ml beat cup, and an insect vacuum device, were compared for accuracy to an absolute method and to themselves for precision and efficiency of sampling thrips. Thrips counts of all relative sampling methods were highly correlated (R > 0.92) to the absolute method. The aspirator method was the most accurate compared with the absolute sample according to regression analysis in 2000. In 2003, all sampling methods were considered accurate according to Dunnett's test, but thrips numbers were lower and sample variation was greater than in 2000. In 2000, the beat cup method had the lowest relative variation (RV) or best precision, at 1 and 8 d after transplant (DAT). Only the beat cup method had RV values <25 for all sampling dates. In 2003, the beat cup method had the lowest RV value at 15 and 21 DAT. The beat cup method also was the most efficient method for all sample dates in both years. Frankliniella fusca (Pergande) was the most abundant thrips species on the foliage of preflowering tomato in both years of study at this location. Overall, the best thrips sampling technique tested was the beat cup method in terms of precision and sampling efficiency.

  1. Ablative efficiency of lithium triborate laser vaporization and conventional transurethral resection of the prostate: a comparison using transrectal three-dimensional ultrasound volumetry

    NASA Astrophysics Data System (ADS)

    Gross, Oliver; Sulser, Tullio; Hefermehl, Lukas J.; Strebel, Daniel D.; Largo, Remo; Mortezavi, Ashkan; Poyet, Cédric; Eberli, Daniel; Zimmermann, Matthias; Müller, Alexander; Michel, Maurice S.; Müntener, Michael; Seifert, Hans-Helge; Hermanns, Thomas

    2011-03-01

    Introduction and objectives: It is unknown if tissue ablation following 120W lithium triborate (LBO) laser vaporization (LV) of the prostate is comparable to that following transurethral resection of the prostate (TURP). Therefore, transrectal 3D-ultrasound volumetry of the prostate was performed to compare the efficiency of tissue ablation between LBO-LV and TURP. Methods: Between 03/2008 and 03/2010 110 patients underwent routine LBO-LV (n=61) or TURP (n=49). Transrectal 3D-ultrasound with planimetric volumetry of the prostate was performed pre-operatively, after catheter removal, 6 weeks and 6 months. Results: Median prostate volume was 52.5ml in the LV group and 46.9ml in the TURP group. After catheter removal, median absolute volume reduction (LV: 7.05ml, TURP: 15.8ml) and relative volume reduction (15.9% vs. 34.2%) were significantly lower in the LV group (p<0.001). After 6 weeks/ 6 months, the relative volume reduction but not the absolute remained significantly lower in the LV group. Conclusions: LBO-LV is an efficient procedure evidenced by an absolute tissue ablation not significantly different to that after TURP. However, TURP seems to be superior due to a higher relative tissue ablation. The differences in tissue ablation had no impact on the early clinical outcome. Delayed volume reduction indicates that prostatic swelling occurs early after LV and then decreases subsequently.

  2. Bio-Inspired Stretchable Absolute Pressure Sensor Network

    PubMed Central

    Guo, Yue; Li, Yu-Hung; Guo, Zhiqiang; Kim, Kyunglok; Chang, Fu-Kuo; Wang, Shan X.

    2016-01-01

    A bio-inspired absolute pressure sensor network has been developed. Absolute pressure sensors, distributed on multiple silicon islands, are connected as a network by stretchable polyimide wires. This sensor network, made on a 4’’ wafer, has 77 nodes and can be mounted on various curved surfaces to cover an area up to 0.64 m × 0.64 m, which is 100 times larger than its original size. Due to Micro Electro-Mechanical system (MEMS) surface micromachining technology, ultrathin sensing nodes can be realized with thicknesses of less than 100 µm. Additionally, good linearity and high sensitivity (~14 mV/V/bar) have been achieved. Since the MEMS sensor process has also been well integrated with a flexible polymer substrate process, the entire sensor network can be fabricated in a time-efficient and cost-effective manner. Moreover, an accurate pressure contour can be obtained from the sensor network. Therefore, this absolute pressure sensor network holds significant promise for smart vehicle applications, especially for unmanned aerial vehicles. PMID:26729134

  3. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    NASA Astrophysics Data System (ADS)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  4. SU-F-T-330: Characterization of the Clinically Released ScandiDos Discover Diode Array for In-Vivo Dose Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saenz, D; Gutierrez, A

    Purpose: The ScandiDos Discover has obtained FDA clearance and is now clinically released. We studied the essential attenuation and beam hardening components as well as tested the diode array’s ability to detect changes in absolute dose and MLC leaf positions. Methods: The ScandiDos Discover was mounted on the heads of an Elekta VersaHD and a Varian 23EX. Beam attenuation measurements were made at 10 cm depth for 6 MV and 18 MV beam energies. The PDD(10) was measured as a metric for the effect on beam quality. Next, a plan consisting of two orthogonal 10 × 10 cm2 fields wasmore » used to adjust the dose per fraction by scaling monitor units to test the absolute dose detection sensitivity of the Discover. A second plan (conformal arc) was then delivered several times independently on the Elekta VersaHD. Artificially introduced MLC position errors in the four central leaves were then added. The errors were incrementally increased from 1 mm to 4 mm and back across seven control points. Results: The absolute dose measured at 10 cm depth decreased by 1.2% and 0.7% for 6 MV and 18 MV beam with the Discover, respectively. Attenuation depended slightly on the field size but only changed the attenuation by 0.1% across 5 × 5 cm{sup 2} and 20 − 20 cm{sup 2} fields. The change in PDD(10) for a 10 − 10 cm{sup 2} field was +0.1% and +0.6% for 6 MV and 18 MV, respectively. Changes in monitor units from −5.0% to 5.0% were faithfully detected. Detected leaf errors were within 1.0 mm of intended errors. Conclusion: A novel in-vivo dosimeter monitoring the radiation beam during treatment was examined through its attenuation and beam hardening characteristics. The device tracked with changes in absolute dose as well as introduced leaf position deviations.« less

  5. On-line high-performance liquid chromatography-ultraviolet-nuclear magnetic resonance method of the markers of nerve agents for verification of the Chemical Weapons Convention.

    PubMed

    Mazumder, Avik; Gupta, Hemendra K; Garg, Prabhat; Jain, Rajeev; Dubey, Devendra K

    2009-07-03

    This paper details an on-flow liquid chromatography-ultraviolet-nuclear magnetic resonance (LC-UV-NMR) method for the retrospective detection and identification of alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs), the markers of the toxic nerve agents for verification of the Chemical Weapons Convention (CWC). Initially, the LC-UV-NMR parameters were optimized for benzyl derivatives of the APAs and AAPAs. The optimized parameters include stationary phase C(18), mobile phase methanol:water 78:22 (v/v), UV detection at 268nm and (1)H NMR acquisition conditions. The protocol described herein allowed the detection of analytes through acquisition of high quality NMR spectra from the aqueous solution of the APAs and AAPAs with high concentrations of interfering background chemicals which have been removed by preceding sample preparation. The reported standard deviation for the quantification is related to the UV detector which showed relative standard deviations (RSDs) for quantification within +/-1.1%, while lower limit of detection upto 16mug (in mug absolute) for the NMR detector. Finally the developed LC-UV-NMR method was applied to identify the APAs and AAPAs in real water samples, consequent to solid phase extraction and derivatization. The method is fast (total experiment time approximately 2h), sensitive, rugged and efficient.

  6. Limiting loss mechanisms in 23% efficient silicon solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aberle, A.G.; Altermatt, P.P.; Heiser, G.

    1995-04-01

    The ``passivated emitter and rear locally diffused`` (PERL) silicon solar cell structure presently demonstrates the highest terrestrial performance of any silicon-based solar cell. This paper presents a detailed investigation of the limiting loss mechanisms in PERL cells exhibiting independently confirmed 1-sun efficiencies of up to 23.0%. Optical, resistive, and recombinative losses are all analyzed under the full range of solar cell operating conditions with the aid of two-dimensional (2D) device simulations. The analysis is based on measurements of the reflectance, quantum efficiency, dark and illuminated current--voltage ({ital I}--{ital V}) characteristics, and properties of the Si--SiO{sub 2} interfaces employed on thesemore » cells for surface passivation. Through the use of the 2D simulations, particular attention has been paid to the magnitudes of the spatially resolved recombination losses in these cells. It is shown that approximately 50% of the recombination losses at the 1-sun maximum power point occur in the base of the cells, followed by recombination losses at the rear and front oxidized surfaces (25% and {lt}25%, respectively). The relatively low fill factors of PERL cells are principally a result of resistive losses; however, the recombination behavior in the base and at the rear surface also contributes. This work predicts that the efficiency of 23% PERL cells could be increased by about 0.7% absolute if ohmic losses were eliminated, a further 1.1% absolute if there were no reflection losses at the nonmetallized front surface regions, about 2.0% by introducing ideal light trapping and eliminating shading losses due to the front metallization, and by about 3.7% absolute if the device had no defect-related recombination losses. New design rules for future efficiency improvements, evident from this analysis, are also presented. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.« less

  7. Application of Nanofiber-packed SPE for Determination of Urinary 1-Hydroxypyrene Level Using HPLC.

    PubMed

    Ifegwu, Okechukwu Clinton; Anyakora, Chimezie; Chigome, Samuel; Torto, Nelson

    2014-01-01

    It is always desirable to achieve maximum sample clean-up, extraction, and pre-concentration with the minimum possible organic solvent. The miniaturization of sample preparation devices was successfully demonstrated by packing 10 mg of 11 electrospun polymer nanofibers into pipette tip micro column and mini disc cartridges for efficient pre-concentration of 1-hydroxypyrene in urine samples. 1-hydroxypyrene is an extensively studied biomarker of the largest class of chemical carcinogens. Excretory 1-hydroxypyrene was monitored with HPLC/fluorescence detector. Important parameters influencing the percentage recovery such as fiber diameter, fiber packing amount, eluent, fiber packing format, eluent volume, surface area, porosity, and breakthrough parameters were thoroughly studied and optimized. Under optimized condition, there was a near perfect linearity of response in the range of 1-1000 μg/L with a coefficient of determination (r (2)) between 0.9992 and 0.9999 and precision (% RSD) ≤7.64% (n = 6) for all the analysis (10, 25, and 50 μg/L). The Limit of detection (LOD) was between 0.022 and 0.15 μg/L. When compared to the batch studies, both disc packed nanofiber sorbents and pipette tip packed sorbents exhibited evident dominance based on their efficiencies. The experimental results showed comparable absolute recoveries for the mini disc packed fibers (84% for Nylon 6) and micro columns (80% for Nylon 6), although the disc displayed slightly higher recoveries possibly due to the exposure of the analyte to a larger reacting surface. The results also showed highly comparative extraction efficiencies between the nanofibers and conventional C-18 SPE sorbent. Nevertheless, miniaturized SPE devices simplified sample preparation, reducing back pressure, time of the analysis with acceptable reliability, selectivity, detection levels, and environmental friendliness, hence promoting green chemistry.

  8. 237Np absolute delayed neutron yield measurements

    NASA Astrophysics Data System (ADS)

    Doré, D.; Ledoux, X.; Nolte, R.; Gagnon-Moisan, F.; Thulliez, L.; Litaize, O.; Roettger, S.; Serot, O.

    2017-09-01

    237Np absolute delayed neutron yields have been measured at different incident neutron energies from 1.5 to 16 MeV. The experiment was performed at the Physikalisch-Technische Bundesanstalt (PTB) facility where the Van de Graaff accelerator and the cyclotron CV28 delivered 9 different neutron energy beams using p+T, d+D and d+T reactions. The detection system is made up of twelve 3He tubes inserted into a polyethylene cylinder. In this paper, the experimental setup and the data analysis method are described. The evolution of the absolute DN yields as a function of the neutron incident beam energies are presented and compared to experimental data found in the literature and data from the libraries.

  9. 242Pu absolute neutron-capture cross section measurement

    NASA Astrophysics Data System (ADS)

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; O'Donnell, J. M.; Ullmann, J. L.

    2017-09-01

    The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. During target fabrication, a small amount of 239Pu was added to the active target so that the absolute scale of the 242Pu(n,γ) cross section could be set according to the known 239Pu(n,f) resonance at En,R = 7.83 eV. The relative scale of the 242Pu(n,γ) cross section covers four orders of magnitude for incident neutron energies from thermal to ≈ 40 keV. The cross section reported in ENDF/B-VII.1 for the 242Pu(n,γ) En,R = 2.68 eV resonance was found to be 2.4% lower than the new absolute 242Pu(n,γ) cross section.

  10. Efficiency at Sorting Cards in Compressed Air

    PubMed Central

    Poulton, E. C.; Catton, M. J.; Carpenter, A.

    1964-01-01

    At a site where compressed air was being used in the construction of a tunnel, 34 men sorted cards twice, once at normal atmospheric pressure and once at 3½, 2½, or 2 atmospheres absolute pressure. An additional six men sorted cards twice at normal atmospheric pressure. When the task was carried out for the first time, all the groups of men performing at raised pressure were found to yield a reliably greater proportion of very slow responses than the group of men performing at normal pressure. There was reliably more variability in timing at 3½ and 2½ atmospheres absolute than at normal pressure. At 3½ atmospheres absolute the average performance was also reliably slower. When the task was carried out for the second time, exposure to 3½ atmospheres absolute pressure had no reliable effect. Thus compressed air affected performance only while the task was being learnt; it had little effect after practice. No reliable differences were found related to age, to length of experience in compressed air, or to the duration of the exposure to compressed air, which was never less than 10 minutes at 3½ atmospheres absolute pressure. PMID:14180485

  11. Psychophysical Criteria for Visual Simulation Systems.

    DTIC Science & Technology

    1980-05-01

    definitive data were found to estab- lish detection thresholds; therefore, this is one area where a psycho- physical study was recommended. Differential size...The specific functional relationships needinq quantification were the following: 1. The effect of Horizontal Aniseikonia on Target Detection and...Transition Technique 6. The Effects of Scene Complexity and Separation on the Detection of Scene Misalignment 7. Absolute Brightness Levels in

  12. Total and dissociative photoionization cross sections of N2 from threshold to 107 eV

    NASA Technical Reports Server (NTRS)

    Samson, James A. R.; Masuoka, T.; Pareek, P. N.; Angel, G. C.

    1986-01-01

    The absolute cross sections for the production of N(+) and N2(+) were measured from the dissociative ionization threshold of 115 A. In addition, the absolute photoabsorption and photoionization cross sections were tabulated between 114 and 796 A. The ionization efficiencies were also given at several discrete wave lengths between 660 and 790 A. The production of N(+) fragment ions are discussed in terms of the doubly excited N2(+) states with binding energies in the range of 24 to 44 eV.

  13. Total and dissociative photoionization cross sections of N2 from threshold to 107 eV

    NASA Technical Reports Server (NTRS)

    Samson, James A. R.; Masuoka, T.; Pareek, P. N.; Angel, G. C.

    1987-01-01

    The absolute cross sections for the production of N(+) and N2(+) have been measured from the dissociative ionization threshold to 115 A. In addition, the absolute photoabsorption and photoionization cross sections are tabulated between 114 and 796 A. The ionization efficiencies are also given at several discrete wavelengths between 660 and 790 A. The production of N(+) fragment ions are discussed in terms of the doubly excited N2(+) states with binding energies in the range 24 to 44 eV.

  14. Method of differential-phase/absolute-amplitude QAM

    DOEpatents

    Dimsdle, Jeffrey William [Overland Park, KS

    2007-07-03

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  15. Method of differential-phase/absolute-amplitude QAM

    DOEpatents

    Dimsdle, Jeffrey William [Overland Park, KS

    2008-10-21

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  16. Method of differential-phase/absolute-amplitude QAM

    DOEpatents

    Dimsdle, Jeffrey William [Overland Park, KS

    2009-09-01

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  17. Method of differential-phase/absolute-amplitude QAM

    DOEpatents

    Dimsdle, Jeffrey William [Overland Park, KS

    2007-07-17

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  18. Method of differential-phase/absolute-amplitude QAM

    DOEpatents

    Dimsdle, Jeffrey William

    2007-10-02

    A method of quadrature amplitude modulation involving encoding phase differentially and amplitude absolutely, allowing for a high data rate and spectral efficiency in data transmission and other communication applications, and allowing for amplitude scaling to facilitate data recovery; amplitude scale tracking to track-out rapid and severe scale variations and facilitate successful demodulation and data retrieval; 2.sup.N power carrier recovery; incoherent demodulation where coherent carrier recovery is not possible or practical due to signal degradation; coherent demodulation; multipath equalization to equalize frequency dependent multipath; and demodulation filtering.

  19. Neutron activation measurements over an extremely wide dynamic range (invited) (abstract)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, C.W.

    1997-01-01

    The DT program at the Tokamak Fusion Test Reactor (TFTR) created requirements on 14 MeV neutron measurements to measure from 10{sup 6} n/cm{sup 2} (for triton burnup and Ohmic tritium plasmas) to {gt}10{sup 12} n/cm{sup 2} (characteristic of {gt}10 MW DT plasmas) with an accuracy of 7% (one-sigma).1 To maintain an absolute calibration over this dynamic range with active neutron detectors required one to go from some absolute standard at one fluence level to a measurement at a much higher fluence. Maintaining accuracy requires an extremely linear set of measurements not systematically affected over this dynamic range. Neutron activation canmore » provide such linearity when care is taken with a number of effects such as gamma-ray detection efficiency and sample contamination.2 Absolutely calibrated neutron yield measurements using dosimetric (well-known cross section) reactions with thin (low-mass) elemental foils is be described. This technique makes the detector comparison to an absolute standard of gamma-ray activity correspond to all neutron fluences by reducing the sample mass while keeping the activation detectors operating in a linear counting mode; i.e., low count rates which minimize pileup effects. The International Thermonuclear Experimental Reactor is projected to have 1000 s burn durations at fluxes of few 10{sup 13} n/cm{sup 2}s, or more neutron fluence {ital per second} than entire TFTR discharges. Extrapolating neutron activation to these higher fluences will require yet more care. Some of the issues at such high fluences will be discussed.3 The National Ignition Facility (NIF) is projected to yield 10 MJ of fusion energy, or up to 10{sup 12} n/cm{sup 2} at the vacuum vessel wall, similar to TFTR DT conditions. It is expected that much interesting physics will be performed at yields far less than those from ignition, covering an even greater dynamic range than needed on TFTR. Thin foil techniques do not have the sensitivity required at low fluences.« less

  20. Behavior of Multiclass Pesticide Residue Concentrations during the Transformation from Rose Petals to Rose Absolute.

    PubMed

    Tascone, Oriane; Fillâtre, Yoann; Roy, Céline; Meierhenrich, Uwe J

    2015-05-27

    This study investigates the concentrations of 54 multiclass pesticides during the transformation processes from rose petal to concrete and absolute using roses spiked with pesticides as a model. The concentrations of the pesticides were followed during the process of transforming the spiked rose flowers from an organic field into concrete and then into absolute. The rose flowers, the concrete, and the absolute, as well as their transformation intermediates, were analyzed for pesticide content using gas chromatography/tandem mass spectrometry. We observed that all the pesticides were extracted and concentrated in the absolute, with the exception of three molecules: fenthion, fenamiphos, and phorate. Typical pesticides were found to be concentrated by a factor of 100-300 from the rose flowers to the rose absolute. The observed effect of pesticide enrichment was also studied in roses and their extracts from four classically phytosanitary treated fields. Seventeen pesticides were detected in at least one of the extracts. Like the case for the spiked samples in our model, the pesticides present in the rose flowers from Turkey were concentrated in the absolute. Two pesticides, methidathion and chlorpyrifos, were quantified in the rose flowers at approximately 0.01 and 0.01-0.05 mg kg(-1), respectively, depending on the treated field. The concentrations determined for the corresponding rose absolutes were 4.7 mg kg(-1) for methidathion and 0.65-27.25 mg kg(-1) for chlorpyrifos.

  1. The good, the bad and the outliers: automated detection of errors and outliers from groundwater hydrographs

    NASA Astrophysics Data System (ADS)

    Peterson, Tim J.; Western, Andrew W.; Cheng, Xiang

    2018-03-01

    Suspicious groundwater-level observations are common and can arise for many reasons ranging from an unforeseen biophysical process to bore failure and data management errors. Unforeseen observations may provide valuable insights that challenge existing expectations and can be deemed outliers, while monitoring and data handling failures can be deemed errors, and, if ignored, may compromise trend analysis and groundwater model calibration. Ideally, outliers and errors should be identified but to date this has been a subjective process that is not reproducible and is inefficient. This paper presents an approach to objectively and efficiently identify multiple types of errors and outliers. The approach requires only the observed groundwater hydrograph, requires no particular consideration of the hydrogeology, the drivers (e.g. pumping) or the monitoring frequency, and is freely available in the HydroSight toolbox. Herein, the algorithms and time-series model are detailed and applied to four observation bores with varying dynamics. The detection of outliers was most reliable when the observation data were acquired quarterly or more frequently. Outlier detection where the groundwater-level variance is nonstationary or the absolute trend increases rapidly was more challenging, with the former likely to result in an under-estimation of the number of outliers and the latter an overestimation in the number of outliers.

  2. Microfabricated Collector-Generator Electrode Sensor for Measuring Absolute pH and Oxygen Concentrations.

    PubMed

    Dengler, Adam K; Wightman, R Mark; McCarty, Gregory S

    2015-10-20

    Fast-scan cyclic voltammetry (FSCV) has attracted attention for studying in vivo neurotransmission due to its subsecond temporal resolution, selectivity, and sensitivity. Traditional FSCV measurements use background subtraction to isolate changes in the local electrochemical environment, providing detailed information on fluctuations in the concentration of electroactive species. This background subtraction removes information about constant or slowly changing concentrations. However, determination of background concentrations is still important for understanding functioning brain tissue. For example, neural activity is known to consume oxygen and produce carbon dioxide which affects local levels of oxygen and pH. Here, we present a microfabricated microelectrode array which uses FSCV to detect the absolute levels of oxygen and pH in vitro. The sensor is a collector-generator electrode array with carbon microelectrodes spaced 5 μm apart. In this work, a periodic potential step is applied at the generator producing transient local changes in the electrochemical environment. The collector electrode continuously performs FSCV enabling these induced changes in concentration to be recorded with the sensitivity and selectivity of FSCV. A negative potential step applied at the generator produces a transient local pH shift at the collector. The generator-induced pH signal is detected using FSCV at the collector and correlated to absolute solution pH by postcalibration of the anodic peak position. In addition, in oxygenated solutions a negative potential step at the generator produces hydrogen peroxide by reducing oxygen. Hydrogen peroxide is detected with FSCV at the collector electrode, and the magnitude of the oxidative peak is proportional to absolute oxygen concentrations. Oxygen interference on the pH signal is minimal and can be accounted for with a postcalibration.

  3. Nd/sup 3 +/ fluorescence quantum-efficiency measurements with photoacoustics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosencwaig, A.; Hildum, E.A.

    1981-04-01

    We have investigated the use of photoacoustic techniques for obtaining absolute values of fluorescence quantum efficiencies in lightly doped Nd/sup 3 +/ laser materials. We have found that surface absorptions play an important role in gas-microphone measurements, and that thermal profiles are important in piezoelectric measurements. We have obtained fluorescence quantum efficiencies for Nd/sup 3 +/ in yttrium aluminum garnet, and in silicate and borate glasses that are in good agreement with lifetime measurements and Judd-Ofelt calculations.

  4. An experiment to measure the one-way velocity of propagation of electromagnetic radiation

    NASA Technical Reports Server (NTRS)

    Kolen, P.; Torr, D. G.

    1982-01-01

    An experiment involving commercially available instrumentation to measure the velocity of the earth with respect to absolute space is described. The experiment involves the measurement of the one-way propagation velocity of electromagnetic radiation down a high-quality coaxial cable. It is demonstrated that the experiment is both physically meaningful and exceedingly simple in concept and in implementation. It is shown that with currently available commercial equipment one might expect to detect a threshold value for the component of velocity of the earth's motion with respect to absolute space in the equatorial plane of approximately 10 km/s, which greatly exceeds the velocity resolution required to detect the motion of the solar system with respect to the center of the galaxy.

  5. 49 CFR 214.337 - On-track safety procedures for lone workers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-track equipment is not impaired by background noise, lights, precipitation, fog, passing trains, or any... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...

  6. Generic method for the absolute quantification of glutathione S-conjugates: Application to the conjugates of acetaminophen, clozapine and diclofenac.

    PubMed

    den Braver, Michiel W; Vermeulen, Nico P E; Commandeur, Jan N M

    2017-03-01

    Modification of cellular macromolecules by reactive drug metabolites is considered to play an important role in the initiation of tissue injury by many drugs. Detection and identification of reactive intermediates is often performed by analyzing the conjugates formed after trapping by glutathione (GSH). Although sensitivity of modern mass spectrometrical methods is extremely high, absolute quantification of GSH-conjugates is critically dependent on the availability of authentic references. Although 1 H NMR is currently the method of choice for quantification of metabolites formed biosynthetically, its intrinsically low sensitivity can be a limiting factor in quantification of GSH-conjugates which generally are formed at low levels. In the present study, a simple but sensitive and generic method for absolute quantification of GSH-conjugates is presented. The method is based on quantitative alkaline hydrolysis of GSH-conjugates and subsequent quantification of glutamic acid and glycine by HPLC after precolumn derivatization with o-phthaldialdehyde/N-acetylcysteine (OPA/NAC). Because of the lower stability of the glycine OPA/NAC-derivate, quantification of the glutamic acid OPA/NAC-derivate appeared most suitable for quantification of GSH-conjugates. The novel method was used to quantify the concentrations of GSH-conjugates of diclofenac, clozapine and acetaminophen and quantification was consistent with 1 H NMR, but with a more than 100-fold lower detection limit for absolute quantification. Copyright © 2017. Published by Elsevier B.V.

  7. Optimal design of the absolute positioning sensor for a high-speed maglev train and research on its fault diagnosis.

    PubMed

    Zhang, Dapeng; Long, Zhiqiang; Xue, Song; Zhang, Junge

    2012-01-01

    This paper studies an absolute positioning sensor for a high-speed maglev train and its fault diagnosis method. The absolute positioning sensor is an important sensor for the high-speed maglev train to accomplish its synchronous traction. It is used to calibrate the error of the relative positioning sensor which is used to provide the magnetic phase signal. On the basis of the analysis for the principle of the absolute positioning sensor, the paper describes the design of the sending and receiving coils and realizes the hardware and the software for the sensor. In order to enhance the reliability of the sensor, a support vector machine is used to recognize the fault characters, and the signal flow method is used to locate the faulty parts. The diagnosis information not only can be sent to an upper center control computer to evaluate the reliability of the sensors, but also can realize on-line diagnosis for debugging and the quick detection when the maglev train is off-line. The absolute positioning sensor we study has been used in the actual project.

  8. High efficiency microfluidic beta detector for pharmacokinetic studies in small animals

    NASA Astrophysics Data System (ADS)

    Convert, Laurence; Girard-Baril, Frédérique; Renaudin, Alan; Grondin, Étienne; Jaouad, Abdelatif; Aimez, Vincent; Charette, Paul; Lecomte, Roger

    2011-10-01

    New radiotracers are continuously being developed to improve diagnostic efficiency using Single Photon Emission Computed Tomography (SPECT) or Positron Emission Tomography (PET). The characterization of their pharmacokinetics requires blood radioactivity monitoring over time during the scan and is very challenging in small animals because of the low volume of blood available. In this work, a prototype microfluidic blood counter made of a microchannel atop a silicon substrate containing PIN photodiodes is proposed to improve beta detection efficiency in a small volume by eliminating unnecessary interfaces between fluid and detector. A flat rectangular-shaped epoxy channel, 36 μm×1.26 mm cross section and 31.5 mm in length, was microfabricated over a die containing an array of 2×2 mm 2 PIN photodiodes, leaving only a few micrometers of epoxy floor layer between the fluid and the photodiode sensitive surface. This geometry leads to a quasi 2D source, optimizing geometrical detection efficiency that was estimated at 41% using solid angle calculation. CV- IV measurements were made at each fabrication step to confirm that the microchannel components had no significant effects on the diodes' electrical characteristics. The chip was wire-bonded to a PCB and connected to charge sensitive preamplifier and amplifier modules for pulse shaping. Energy spectra recorded for different isotopes showed continuous beta distribution for PET isotopes and monoenergetic conversion electron peaks for 99mTc. Absolute sensitivity was determined for the most popular PET and SPECT radioisotopes and ranged from 26% to 33% for PET tracers ( 18F, 13N, 11C, 68Ga) and more than 2% for 99mTc. Input functions were successfully simulated with 18F, confirming the setup's suitability for pharmacokinetic modeling of PET and SPECT radiotracers in animal experiments. By using standard materials and procedures, the fabrication process is well suited to on-chip microfluidic functionality, allowing full characterization of new radiotracers.

  9. Characterization of a 2 × 2 array of large square bars of LaBr3:Ce detectors with γ-rays up to 22.5 MeV

    NASA Astrophysics Data System (ADS)

    Dhibar, M.; Mazumdar, I.; Chavan, P. B.; Patel, S. M.; Anil Kumar, G.

    2018-03-01

    LaBr3:Ce scintillators have recently become commercially available in sizes large enough for measurements of high energy gamma-rays. In this communication, we report our studies on properties and response of large volume square bars (2‧‧ ×2‧‧ ×8‧‧) of LaBr3:Ce detectors, individually, and in a compact array of four square bars, with gamma-rays up to 22.5 MeV. The properties studied are, uniformity of the crystal, internal radioactivity, energy resolution, timing resolution, linearity of the response and detection efficiencies. The response of the detectors for 22.5 MeV γ-rays produced from 11B(p , γ)12C capture reaction and for 15.1 MeV γ-rays produced from 12C(p ,p‧ γ)12C inelastic scattering reaction are studied in detail. The measured absolute efficiencies (both total detection and photo-peak) for 662 keV gamma-rays from 137Cs are compared to those obtained using realistic GEANT4 simulations. The primary aim of the array is to measure high energy gamma-rays (5-50 MeV) produced from the de-excitation of excited Giant Dipole Resonance (GDR) states, radiative capture reactions, nuclear Bremsstrahlung process and inelastic scattering process. The highly satisfactory performance of the array provides the impetus for future efforts toward building a bigger array.

  10. Development of a novel handheld intra-operative laparoscopic Compton camera for 18F-Fluoro-2-deoxy-2-D-glucose-guided surgery

    NASA Astrophysics Data System (ADS)

    Nakamura, Y.; Shimazoe, K.; Takahashi, H.; Yoshimura, S.; Seto, Y.; Kato, S.; Takahashi, M.; Momose, T.

    2016-08-01

    As well as pre-operative roadmapping by 18F-Fluoro-2-deoxy-2-D-glucose (FDG) positron emission tomography, intra-operative localization of the tracer is important to identify local margins for less-invasive surgery, especially FDG-guided surgery. The objective of this paper is to develop a laparoscopic Compton camera and system aimed at use for intra-operative FDG imaging for accurate and less-invasive dissections. The laparoscopic Compton camera consists of four layers of a 12-pixel cross-shaped array of GFAG crystals (2× 2× 3 mm3) and through silicon via multi-pixel photon counters and dedicated individual readout electronics based on a dynamic time-over-threshold method. Experimental results yielded a spatial resolution of 4 mm (FWHM) for a 10 mm working distance and an absolute detection efficiency of 0.11 cps kBq-1, corresponding to an intrinsic detection efficiency of  ˜0.18%. In an experiment using a NEMA-like well-shaped FDG phantom, a φ 5× 10 mm cylindrical hot spot was clearly obtained even in the presence of a background distribution surrounding the Compton camera and the hot spot. We successfully obtained reconstructed images of a resected lymph node and primary tumor ex vivo after FDG administration to a patient having esophageal cancer. These performance characteristics indicate a new possibility of FDG-directed surgery by using a Compton camera intra-operatively.

  11. Evaluation of the plasma hydrogen isotope content by residual gas analysis at JET and AUG

    NASA Astrophysics Data System (ADS)

    Drenik, A.; Alegre, D.; Brezinsek, S.; De Castro, A.; Kruezi, U.; Oberkofler, M.; Panjan, M.; Primc, G.; Reichbauer, T.; Resnik, M.; Rohde, V.; Seibt, M.; Schneider, P. A.; Wauters, T.; Zaplotnik, R.; ASDEX-Upgrade, the; EUROfusion MST1 Teams; contributors, JET

    2017-12-01

    The isotope content of the plasma reflects on the dynamics of isotope changeover experiments, efficiency of wall conditioning and the performance of a fusion device in the active phase of operation. The assessment of the isotope ratio of hydrogen and methane molecules is used as a novel method of assessing the plasma isotope ratios at JET and ASDEX-Upgrade (AUG). The isotope ratios of both molecules in general shows similar trends as the isotope ratio detected by other diagnostics. At JET, the absolute values of RGA signals are in relatively good agreement with each other and with spectroscopy data, while at AUG the deviation from neutral particle analyser data are larger, and the results show a consistent spatial distribution of the isotope ratio. It is further shown that the isotope ratio of the hydrogen molecule can be used to study the degree of dissociation of the injected gas during changeover experiments.

  12. Graph-based real-time fault diagnostics

    NASA Technical Reports Server (NTRS)

    Padalkar, S.; Karsai, G.; Sztipanovits, J.

    1988-01-01

    A real-time fault detection and diagnosis capability is absolutely crucial in the design of large-scale space systems. Some of the existing AI-based fault diagnostic techniques like expert systems and qualitative modelling are frequently ill-suited for this purpose. Expert systems are often inadequately structured, difficult to validate and suffer from knowledge acquisition bottlenecks. Qualitative modelling techniques sometimes generate a large number of failure source alternatives, thus hampering speedy diagnosis. In this paper we present a graph-based technique which is well suited for real-time fault diagnosis, structured knowledge representation and acquisition and testing and validation. A Hierarchical Fault Model of the system to be diagnosed is developed. At each level of hierarchy, there exist fault propagation digraphs denoting causal relations between failure modes of subsystems. The edges of such a digraph are weighted with fault propagation time intervals. Efficient and restartable graph algorithms are used for on-line speedy identification of failure source components.

  13. Universality of Generalized Bunching and Efficient Assessment of Boson Sampling.

    PubMed

    Shchesnovich, V S

    2016-03-25

    It is found that identical bosons (fermions) show a generalized bunching (antibunching) property in linear networks: the absolute maximum (minimum) of the probability that all N input particles are detected in a subset of K output modes of any nontrivial linear M-mode network is attained only by completely indistinguishable bosons (fermions). For fermions K is arbitrary; for bosons it is either (i) arbitrary for only classically correlated bosons or (ii) satisfies K≥N (or K=1) for arbitrary input states of N particles. The generalized bunching allows us to certify in a polynomial in N number of runs that a physical device realizing boson sampling with an arbitrary network operates in the regime of full quantum coherence compatible only with completely indistinguishable bosons. The protocol needs only polynomial classical computations for the standard boson sampling, whereas an analytic formula is available for the scattershot version.

  14. Network of time-multiplexed optical parametric oscillators as a coherent Ising machine

    NASA Astrophysics Data System (ADS)

    Marandi, Alireza; Wang, Zhe; Takata, Kenta; Byer, Robert L.; Yamamoto, Yoshihisa

    2014-12-01

    Finding the ground states of the Ising Hamiltonian maps to various combinatorial optimization problems in biology, medicine, wireless communications, artificial intelligence and social network. So far, no efficient classical and quantum algorithm is known for these problems and intensive research is focused on creating physical systems—Ising machines—capable of finding the absolute or approximate ground states of the Ising Hamiltonian. Here, we report an Ising machine using a network of degenerate optical parametric oscillators (OPOs). Spins are represented with above-threshold binary phases of the OPOs and the Ising couplings are realized by mutual injections. The network is implemented in a single OPO ring cavity with multiple trains of femtosecond pulses and configurable mutual couplings, and operates at room temperature. We programmed a small non-deterministic polynomial time-hard problem on a 4-OPO Ising machine and in 1,000 runs no computational error was detected.

  15. Temperature monitoring by infrared radiation measurements during ArF excimer laser ablation with cornea

    NASA Astrophysics Data System (ADS)

    Ishihara, Miya; Arai, Tsunenori; Sato, Shunichi; Nakano, Hironori; Obara, Minoru; Kikuchi, Makoto

    1999-06-01

    We measured infrared thermal radiation from porcine cornea during various fluences ArF excimer laser ablations with 1 microsecond(s) rise time. To obtain absolute temperature by means of Stefan-Boltzman law of radiation, we carried out a collection efficiency and detective sensitivity by a pre-experiment using panel heater. We measured the time course of the thermal radiation intensity with various laser fluences. We studied the relation between the peak cornea temperature during the ablation and irradiation fluences. We found the ablation situations, i.e., sub-ablation threshold, normal thermal ablation, and over-heated ablation, may be judged by both of the measured temperature transient waveforms and peak temperature. The boundary fluences corresponding to normal thermal ablation were 90 and 160 mJ/cm2. Our fast remote temperature monitoring during cornea ablation might be useful to control ablation quality/quantity of the cornea ArF laser ablation, that is PRK.

  16. Cytochrome c-553 is not required for photosynthetic activity in the cyanobacterium Synechococcus.

    PubMed Central

    Laudenbach, D E; Herbert, S K; McDowell, C; Fork, D C; Grossman, A R; Straus, N A

    1990-01-01

    In cyanobacteria, the water-soluble cytochrome c-553 functions as a mobile carrier of electrons between the membrane-bound cytochrome b6-f complex and P-700 reaction centers of Photosystem I. The structural gene for cytochrome c-553 (designated cytA) of the cyanobacterium Synechococcus sp. PCC 7942 was cloned, and the deduced amino acid sequence was shown to be similar to known cyanobacterial cytochrome c-553 proteins. A deletion mutant was constructed that had no detectable cytochrome c-553 based on spectral analyses and tetramethylbenzidine-hydrogen peroxide staining of proteins resolved by polyacrylamide gel electrophoresis. The mutant strain was not impaired in overall photosynthetic activity. However, this mutant exhibited a decreased efficiency of cytochrome f oxidation. These results indicate that cytochrome c-553 is not an absolute requirement for reducing Photosystem I reaction centers in Synechococcus sp. PCC 7942. PMID:1967057

  17. International ring trial for the validation of an event-specific Golden Rice 2 quantitative real-time polymerase chain reaction method.

    PubMed

    Jacchia, Sara; Nardini, Elena; Bassani, Niccolò; Savini, Christian; Shim, Jung-Hyun; Trijatmiko, Kurniawan; Kreysa, Joachim; Mazzara, Marco

    2015-05-27

    This article describes the international validation of the quantitative real-time polymerase chain reaction (PCR) detection method for Golden Rice 2. The method consists of a taxon-specific assay amplifying a fragment of rice Phospholipase D α2 gene, and an event-specific assay designed on the 3' junction between transgenic insert and plant DNA. We validated the two assays independently, with absolute quantification, and in combination, with relative quantification, on DNA samples prepared in haploid genome equivalents. We assessed trueness, precision, efficiency, and linearity of the two assays, and the results demonstrate that both the assays independently assessed and the entire method fulfill European and international requirements for methods for genetically modified organism (GMO) testing, within the dynamic range tested. The homogeneity of the results of the collaborative trial between Europe and Asia is a good indicator of the robustness of the method.

  18. Quantum efficiency measurement of the Transiting Exoplanet Survey Satellite (TESS) CCD detectors

    NASA Astrophysics Data System (ADS)

    Krishnamurthy, A.; Villasenor, J.; Thayer, C.; Kissel, S.; Ricker, G.; Seager, S.; Lyle, R.; Deline, A.; Morgan, E.; Sauerwein, T.; Vanderspek, R.

    2016-07-01

    Very precise on-ground characterization and calibration of TESS CCD detectors will significantly assist in the analysis of the science data from the mission. An accurate optical test bench with very high photometric stability has been developed to perform precise measurements of the absolute quantum efficiency. The setup consists of a vacuum dewar with a single MIT Lincoln Lab CCID-80 device mounted on a cold plate with the calibrated reference photodiode mounted next to the CCD. A very stable laser-driven light source is integrated with a closed-loop intensity stabilization unit to control variations of the light source down to a few parts-per-million when averaged over 60 s. Light from the stabilization unit enters a 20 inch integrating sphere. The output light from the sphere produces near-uniform illumination on the cold CCD and on the calibrated reference photodiode inside the dewar. The ratio of the CCD and photodiode signals provides the absolute quantum efficiency measurement. The design, key features, error analysis, and results from the test campaign are presented.

  19. The Dependence of Cloud Property Trend Detection on Absolute Calibration Accuracy of Passive Satellite Sensors

    NASA Astrophysics Data System (ADS)

    Shea, Y.; Wielicki, B. A.; Sun-Mack, S.; Minnis, P.; Zelinka, M. D.

    2016-12-01

    Detecting trends in climate variables on global, decadal scales requires highly accurate, stable measurements and retrieval algorithms. Trend uncertainty depends on its magnitude, natural variability, and instrument and retrieval algorithm accuracy and stability. We applied a climate accuracy framework to quantify the impact of absolute calibration on cloud property trend uncertainty. The cloud properties studied were cloud fraction, effective temperature, optical thickness, and effective radius retrieved using the Clouds and the Earth's Radiant Energy System (CERES) Cloud Property Retrieval System, which uses Moderate-resolution Imaging Spectroradiometer measurements (MODIS). Modeling experiments from the fifth phase of the Climate Model Intercomparison Project (CMIP5) agree that net cloud feedback is likely positive but disagree regarding its magnitude, mainly due to uncertainty in shortwave cloud feedback. With the climate accuracy framework we determined the time to detect trends for instruments with various calibration accuracies. We estimated a relationship between cloud property trend uncertainty, cloud feedback, and Equilibrium Climate Sensitivity and also between effective radius trend uncertainty and aerosol indirect effect trends. The direct relationship between instrument accuracy requirements and climate model output provides the level of instrument absolute accuracy needed to reduce climate model projection uncertainty. Different cloud types have varied radiative impacts on the climate system depending on several attributes, such as their thermodynamic phase, altitude, and optical thickness. Therefore, we also conducted these studies by cloud types for a clearer understanding of instrument accuracy requirements needed to detect changes in their cloud properties. Combining this information with the radiative impact of different cloud types helps to prioritize among requirements for future satellite sensors and understanding the climate detection capabilities of existing sensors.

  20. Transmission Efficiency Measurements and Correlations with Physical Characteristics of the Lubricant

    NASA Technical Reports Server (NTRS)

    Coy, J. J.; Mitchell, A. M.; Hamrock, B. J.

    1984-01-01

    Data from helicopter transmission efficiency tests were compared to physical properties of the eleven lubricants used in those tests. The tests were conducted with the OH-58 helicopter main rotor transmission. Efficiencies ranged from 98.3 to 98.8 percent. The data was examined for correlation of physical properties with efficiency. There was a reasonable correlation of efficiency with absolute viscosity if the viscosity was first corrected for temperature and pressure in the lubricated contact. Between lubricants, efficiency did not correlate well with viscosity at atmospheric pressure. Between lubricants, efficiency did not correlate well with calculated lubricant film forming capacity. Bench type sliding friction and wear measurements could not be correlated to transmission efficiency and component wear.

  1. Analytical correlation of centrifugal compressor design geometry for maximum efficiency with specific speed

    NASA Technical Reports Server (NTRS)

    Galvas, M. R.

    1972-01-01

    Centrifugal compressor performance was examined analytically to determine optimum geometry for various applications as characterized by specific speed. Seven specific losses were calculated for various combinations of inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, blade exit backsweep, and inlet-tip absolute tangential velocity for solid body prewhirl. The losses considered were inlet guide vane loss, blade loading loss, skin friction loss, recirculation loss, disk friction loss, vaneless diffuser loss, and vaned diffuser loss. Maximum total efficiencies ranged from 0.497 to 0.868 for a specific speed range of 0.257 to 1.346. Curves of rotor exit absolute flow angle, inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, head coefficient and blade exit backsweep are presented over a range of specific speeds for various inducer tip speeds to permit rapid selection of optimum compressor size and shape for a variety of applications.

  2. Temperature response of several scintillator materials to light ions

    NASA Astrophysics Data System (ADS)

    Rodríguez-Ramos, M.; Jiménez-Ramos, M. C.; García-Muñoz, M.; García López, J.

    2017-07-01

    Ion beam induced luminescence has been used to study the response of scintillator screens of Y2O3:Eu3+ (P56) and SrGa2S4:Eu2+ (TG-Green) when irradiated with light ions (protons, deuterium and helium particles). The absolute efficiency of the samples has been studied as a function of the ion energy (with energies up to 3.5 MeV), the beam current and the operating temperature. The evolution of the scintillator yield with ion fluence has been carried out for all the scintillators to estimate radiation damage. Finally, measurements of the decay time of these materials using a system of pulsed beam accelerated particles have been done. Among the screens under study, the TG-Green is the best suited material, in terms of absolute efficiency, temporal response and degradation with ion dose, for fast-ion loss detectors in fusion devices.

  3. Beyond Extreme Ultra Violet (BEUV) Radiation from Spherically symmetrical High-Z plasmas

    NASA Astrophysics Data System (ADS)

    Yoshida, Kensuke; Fujioka, Shinsuke; Higashiguchi, Takeshi; Ugomori, Teruyuki; Tanaka, Nozomi; Kawasaki, Masato; Suzuki, Yuhei; Suzuki, Chihiro; Tomita, Kentaro; Hirose, Ryouichi; Eshima, Takeo; Ohashi, Hayato; Nishikino, Masaharu; Scally, Enda; Nshimura, Hiroaki; Azechi, Hiroshi; O'Sullivan, Gerard

    2016-03-01

    Photo-lithography is a key technology for volume manufacture of high performance and compact semiconductor devices. Smaller and more complex structures can be fabricated by using shorter wavelength light in the photolithography. One of the most critical issues in development of the next generation photo-lithography is to increase energy conversion efficiency (CE) from laser to shorter wavelength light. Experimental database of beyond extreme ultraviolet (BEUV) radiation was obtained by using spherically symmetrical high-Z plasmas generated with spherically allocated laser beams. Absolute energy and spectra of BEUV light emitted from Tb, Gd, and Mo plasmas were measured with a absolutely calibrated BEUV calorimeter and a transmission grating spectrometer. 1.0 x 1012 W/cm2 is the optimal laser intensity to produced efficient BEUV light source plasmas with Tb and Gd targets. Maximum CE is achieved at 0.8% that is two times higher than the published CEs obtained with planar targets.

  4. Absolute Configuration from Different Multifragmentation Pathways in Light-Induced Coulomb Explosion Imaging.

    PubMed

    Pitzer, Martin; Kastirke, Gregor; Kunitski, Maksim; Jahnke, Till; Bauer, Tobias; Goihl, Christoph; Trinter, Florian; Schober, Carl; Henrichs, Kevin; Becht, Jasper; Zeller, Stefan; Gassert, Helena; Waitz, Markus; Kuhlins, Andreas; Sann, Hendrik; Sturm, Felix; Wiegandt, Florian; Wallauer, Robert; Schmidt, Lothar Ph H; Johnson, Allan S; Mazenauer, Manuel; Spenger, Benjamin; Marquardt, Sabrina; Marquardt, Sebastian; Schmidt-Böcking, Horst; Stohner, Jürgen; Dörner, Reinhard; Schöffler, Markus; Berger, Robert

    2016-08-18

    The absolute configuration of individual small molecules in the gas phase can be determined directly by light-induced Coulomb explosion imaging (CEI). Herein, this approach is demonstrated for ionization with a single X-ray photon from a synchrotron light source, leading to enhanced efficiency and faster fragmentation as compared to previous experiments with a femtosecond laser. In addition, it is shown that even incomplete fragmentation pathways of individual molecules from a racemic CHBrClF sample can give access to the absolute configuration in CEI. This leads to a significant increase of the applicability of the method as compared to the previously reported complete break-up into atomic ions and can pave the way for routine stereochemical analysis of larger chiral molecules by light-induced CEI. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A novel bio-engineering approach to generate an eminent surface-functionalized template for selective detection of female sex pheromone of Helicoverpa armigera.

    PubMed

    Moitra, Parikshit; Bhagat, Deepa; Pratap, Rudra; Bhattacharya, Santanu

    2016-11-28

    Plant pests exert serious effects on food production due to which the global crop yields are reduced by ~20-40 percent per year. Hence to meet the world's food needs, loses of food due to crop pests must be reduced. Herein the silicon dioxide based MEMS devices are covalently functionalized for robust and efficient optical sensing of the female sex pheromones of the pests like Helicoverpa armigera for the first time in literature. The functionalized devices are also capable of selectively measuring the concentration of this pheromone at femtogram level which is much below the concentration of pheromone at the time of pest infestation in an agricultural field. Experiments are also performed in a confined region in the presence of male and female pests and tomato plants which directly mimics the real environmental conditions. Again the reversible use and absolutely trouble free transportation of these pheromone nanosensors heightens their potentials for commercial use. Overall, a novel and unique approach for the selective and reversible sensing of female sex pheromones of certain hazardous pests is reported herein which may be efficiently and economically carried forward from the research laboratory to the agricultural field.

  6. A novel bio-engineering approach to generate an eminent surface-functionalized template for selective detection of female sex pheromone of Helicoverpa armigera

    NASA Astrophysics Data System (ADS)

    Moitra, Parikshit; Bhagat, Deepa; Pratap, Rudra; Bhattacharya, Santanu

    2016-11-01

    Plant pests exert serious effects on food production due to which the global crop yields are reduced by ~20-40 percent per year. Hence to meet the world’s food needs, loses of food due to crop pests must be reduced. Herein the silicon dioxide based MEMS devices are covalently functionalized for robust and efficient optical sensing of the female sex pheromones of the pests like Helicoverpa armigera for the first time in literature. The functionalized devices are also capable of selectively measuring the concentration of this pheromone at femtogram level which is much below the concentration of pheromone at the time of pest infestation in an agricultural field. Experiments are also performed in a confined region in the presence of male and female pests and tomato plants which directly mimics the real environmental conditions. Again the reversible use and absolutely trouble free transportation of these pheromone nanosensors heightens their potentials for commercial use. Overall, a novel and unique approach for the selective and reversible sensing of female sex pheromones of certain hazardous pests is reported herein which may be efficiently and economically carried forward from the research laboratory to the agricultural field.

  7. Intranasal agomelatine solid lipid nanoparticles to enhance brain delivery: formulation, optimization and in vivo pharmacokinetics

    PubMed Central

    Fatouh, Ahmed M; Elshafeey, Ahmed H; Abdelbary, Ahmed

    2017-01-01

    Purpose Agomelatine is a novel antidepressant drug suffering from an extensive first-pass metabolism leading to a diminished absolute bioavailability. The aim of the study is: first to enhance its absolute bioavailability, and second to increase its brain delivery. Methods To achieve these aims, the nasal route was adopted to exploit first its avoidance of the hepatic first-pass metabolism to increase the absolute bioavailability, and second the direct nose-to-brain pathway to enhance the brain drug delivery. Solid lipid nanoparticles were selected as a drug delivery system to enhance agomelatine permeability across the blood–brain barrier and therefore its brain delivery. Results The optimum solid lipid nanoparticles have a particle size of 167.70 nm ±0.42, zeta potential of −17.90 mV ±2.70, polydispersity index of 0.12±0.10, entrapment efficiency % of 91.25%±1.70%, the percentage released after 1 h of 35.40%±1.13% and the percentage released after 8 h of 80.87%±5.16%. The pharmacokinetic study of the optimized solid lipid nanoparticles revealed a significant increase in each of the plasma peak concentration, the AUC(0–360 min) and the absolute bioavailability compared to that of the oral suspension of Valdoxan® with the values of 759.00 ng/mL, 7,805.69 ng⋅min/mL and 44.44%, respectively. The optimized solid lipid nanoparticles gave a drug-targeting efficiency of 190.02, which revealed more successful brain targeting by the intranasal route compared with the intravenous route. The optimized solid lipid nanoparticles had a direct transport percentage of 47.37, which indicates a significant contribution of the direct nose-to-brain pathway in the brain drug delivery. Conclusion The intranasal administration of agomelatine solid lipid nanoparticles has effectively enhanced both the absolute bioavailability and the brain delivery of agomelatine. PMID:28684900

  8. Single cell digital polymerase chain reaction on self-priming compartmentalization chip

    PubMed Central

    Zhu, Qiangyuan; Qiu, Lin; Xu, Yanan; Li, Guang; Mu, Ying

    2017-01-01

    Single cell analysis provides a new framework for understanding biology and disease, however, an absolute quantification of single cell gene expression still faces many challenges. Microfluidic digital polymerase chain reaction (PCR) provides a unique method to absolutely quantify the single cell gene expression, but only limited devices are developed to analyze a single cell with detection variation. This paper describes a self-priming compartmentalization (SPC) microfluidic digital polymerase chain reaction chip being capable of performing single molecule amplification from single cell. The chip can be used to detect four single cells simultaneously with 85% of sample digitization. With the optimized protocol for the SPC chip, we first tested the ability, precision, and sensitivity of our SPC digital PCR chip by assessing β-actin DNA gene expression in 1, 10, 100, and 1000 cells. And the reproducibility of the SPC chip is evaluated by testing 18S rRNA of single cells with 1.6%–4.6% of coefficient of variation. At last, by detecting the lung cancer related genes, PLAU gene expression of A549 cells at the single cell level, the single cell heterogeneity was demonstrated. So, with the power-free, valve-free SPC chip, the gene copy number of single cells can be quantified absolutely with higher sensitivity, reduced labor time, and reagent. We expect that this chip will enable new studies for biology and disease. PMID:28191267

  9. Single cell digital polymerase chain reaction on self-priming compartmentalization chip.

    PubMed

    Zhu, Qiangyuan; Qiu, Lin; Xu, Yanan; Li, Guang; Mu, Ying

    2017-01-01

    Single cell analysis provides a new framework for understanding biology and disease, however, an absolute quantification of single cell gene expression still faces many challenges. Microfluidic digital polymerase chain reaction (PCR) provides a unique method to absolutely quantify the single cell gene expression, but only limited devices are developed to analyze a single cell with detection variation. This paper describes a self-priming compartmentalization (SPC) microfluidic digital polymerase chain reaction chip being capable of performing single molecule amplification from single cell. The chip can be used to detect four single cells simultaneously with 85% of sample digitization. With the optimized protocol for the SPC chip, we first tested the ability, precision, and sensitivity of our SPC digital PCR chip by assessing β-actin DNA gene expression in 1, 10, 100, and 1000 cells. And the reproducibility of the SPC chip is evaluated by testing 18S rRNA of single cells with 1.6%-4.6% of coefficient of variation. At last, by detecting the lung cancer related genes, PLAU gene expression of A549 cells at the single cell level, the single cell heterogeneity was demonstrated. So, with the power-free, valve-free SPC chip, the gene copy number of single cells can be quantified absolutely with higher sensitivity, reduced labor time, and reagent. We expect that this chip will enable new studies for biology and disease.

  10. Risk aversion affects economic values of blue fox breeding scheme.

    PubMed

    Peura, J; Kempe, R; Strandén, I; Rydhmer, L

    2016-12-01

    The profit and production of an average Finnish blue fox farm was simulated using a deterministic bio-economic farm model. Risk was included using Arrow-Prat absolute risk aversion coefficient and profit variance. Risk-rated economic values were calculated for pregnancy rate, litter loss, litter size, pelt size, pelt quality, pelt colour clarity, feed efficiency and eye infection. With high absolute risk aversion, economic values were lower than with low absolute risk aversion. Economic values were highest for litter loss (18.16 and 26.42 EUR), litter size (13.27 and 19.40 EUR), pregnancy (11.99 and 18.39 EUR) and eye infection (12.39 and 13.81 EUR). Sensitivity analysis showed that selection pressure for improved eye health depended strongly on proportion of culled animals among infected animals and much less on the proportion of infected animals. The economic value of feed efficiency was lower than expected (6.06 and 8.03 EUR). However, it was almost the same magnitude as pelt quality (7.30 and 7.30 EUR) and higher than the economic value of pelt size (3.37 and 5.26 EUR). Risk factors should be considered in blue fox breeding scheme because they change the relative importance of traits. © 2016 Blackwell Verlag GmbH.

  11. Variance associated with walking velocity during force platform gait analysis of a heterogeneous sample of clinically normal dogs.

    PubMed

    Piazza, Alexander M; Binversie, Emily E; Baker, Lauren A; Nemke, Brett; Sample, Susannah J; Muir, Peter

    2017-04-01

    OBJECTIVE To determine whether walking at specific ranges of absolute and relative (V*) velocity would aid efficient capture of gait trial data with low ground reaction force (GRF) variance in a heterogeneous sample of dogs. ANIMALS 17 clinically normal dogs of various breeds, ages, and sexes. PROCEDURES Each dog was walked across a force platform at its preferred velocity, with controlled acceleration within 0.5 m/s 2 . Ranges in V* were created for height at the highest point of the shoulders (withers; WHV*). Variance effects from 8 walking absolute velocity ranges and associated WHV* ranges were examined by means of repeated-measures ANCOVA. RESULTS The individual dog effect provided the greatest contribution to variance. Narrow velocity ranges typically resulted in capture of a smaller percentage of valid trials and were not consistently associated with lower variance. The WHV* range of 0.33 to 0.46 allowed capture of valid trials efficiently, with no significant effects on peak vertical force and vertical impulse. CONCLUSIONS AND CLINICAL RELEVANCE Dogs with severe lameness may be unable to trot or may have a decline in mobility with gait trial repetition. Gait analysis involving evaluation of individual dogs at their preferred absolute velocity, such that dogs are evaluated at a similar V*, may facilitate efficient capture of valid trials without significant effects on GRF. Use of individual velocity ranges derived from a WHV* range of 0.33 to 0.46 can account for heterogeneity and appears suitable for use in clinical trials involving dogs at a walking gait.

  12. Calibration aspects of the JEM-EUSO mission

    NASA Astrophysics Data System (ADS)

    Adams, J. H.; Ahmad, S.; Albert, J.-N.; Allard, D.; Anchordoqui, L.; Andreev, V.; Anzalone, A.; Arai, Y.; Asano, K.; Ave Pernas, M.; Baragatti, P.; Barrillon, P.; Batsch, T.; Bayer, J.; Bechini, R.; Belenguer, T.; Bellotti, R.; Belov, K.; Berlind, A. A.; Bertaina, M.; Biermann, P. L.; Biktemerova, S.; Blaksley, C.; Blanc, N.; Błȩcki, J.; Blin-Bondil, S.; Blümer, J.; Bobik, P.; Bogomilov, M.; Bonamente, M.; Briggs, M. S.; Briz, S.; Bruno, A.; Cafagna, F.; Campana, D.; Capdevielle, J.-N.; Caruso, R.; Casolino, M.; Cassardo, C.; Castellinic, G.; Catalano, C.; Catalano, G.; Cellino, A.; Chikawa, M.; Christl, M. J.; Cline, D.; Connaughton, V.; Conti, L.; Cordero, G.; Crawford, H. J.; Cremonini, R.; Csorna, S.; Dagoret-Campagne, S.; de Castro, A. J.; De Donato, C.; de la Taille, C.; De Santis, C.; del Peral, L.; Dell'Oro, A.; De Simone, N.; Di Martino, M.; Distratis, G.; Dulucq, F.; Dupieux, M.; Ebersoldt, A.; Ebisuzaki, T.; Engel, R.; Falk, S.; Fang, K.; Fenu, F.; Fernández-Gómez, I.; Ferrarese, S.; Finco, D.; Flamini, M.; Fornaro, C.; Franceschi, A.; Fujimoto, J.; Fukushima, M.; Galeotti, P.; Garipov, G.; Geary, J.; Gelmini, G.; Giraudo, G.; Gonchar, M.; González Alvarado, C.; Gorodetzky, P.; Guarino, F.; Guzmán, A.; Hachisu, Y.; Harlov, B.; Haungs, A.; Hernández Carretero, J.; Higashide, K.; Ikeda, D.; Ikeda, H.; Inoue, N.; Inoue, S.; Insolia, A.; Isgrò, F.; Itow, Y.; Joven, E.; Judd, E. G.; Jung, A.; Kajino, F.; Kajino, T.; Kaneko, I.; Karadzhov, Y.; Karczmarczyk, J.; Karus, M.; Katahira, K.; Kawai, K.; Kawasaki, Y.; Keilhauer, B.; Khrenov, B. A.; Kim, J.-S.; Kim, S.-W.; Kim, S.-W.; Kleifges, M.; Klimov, P. A.; Kolev, D.; Kreykenbohm, I.; Kudela, K.; Kurihara, Y.; Kusenko, A.; Kuznetsov, E.; Lacombe, M.; Lachaud, C.; Lee, J.; Licandro, J.; Lim, H.; López, F.; Maccarone, M. C.; Mannheim, K.; Maravilla, D.; Marcelli, L.; Marini, A.; Martinez, O.; Masciantonio, G.; Mase, K.; Matev, R.; Medina-Tanco, G.; Mernik, T.; Miyamoto, H.; Miyazaki, Y.; Mizumoto, Y.; Modestino, G.; Monaco, A.; Monnier-Ragaigne, D.; Morales de los Ríos, J. A.; Moretto, C.; Morozenko, V. S.; Mot, B.; Murakami, T.; Murakami, M. Nagano; Nagata, M.; Nagataki, S.; Nakamura, T.; Napolitano, T.; Naumov, D.; Nava, R.; Neronov, A.; Nomoto, K.; Nonaka, T.; Ogawa, T.; Ogio, S.; Ohmori, H.; Olinto, A. V.; Orleański, P.; Osteria, G.; Panasyuk, M. I.; Parizot, E.; Park, I. H.; Park, H. W.; Pastircak, B.; Patzak, T.; Paul, T.; Pennypacker, C.; Perez Cano, S.; Peter, T.; Picozza, P.; Pierog, T.; Piotrowski, L. W.; Piraino, S.; Plebaniak, Z.; Pollini, A.; Prat, P.; Prévôt, G.; Prieto, H.; Putis, M.; Reardon, P.; Reyes, M.; Ricci, M.; Rodríguez, I.; Rodríguez Frías, M. D.; Ronga, F.; Roth, M.; Rothkaehl, H.; Roudil, G.; Rusinov, I.; Rybczyński, M.; Sabau, M. D.; Sáez-Cano, G.; Sagawa, H.; Saito, A.; Sakaki, N.; Sakata, M.; Salazar, H.; Sánchez, S.; Santangelo, A.; Santiago Crúz, L.; Sanz Palomino, M.; Saprykin, O.; Sarazin, F.; Sato, H.; Sato, M.; Schanz, T.; Schieler, H.; Scotti, V.; Segreto, A.; Selmane, S.; Semikoz, D.; Serra, M.; Sharakin, S.; Shibata, T.; Shimizu, H. M.; Shinozaki, K.; Shirahama, T.; Siemieniec-Oziȩbło, G.; Silva López, H. H.; Sledd, J.; Słomińska, K.; Sobey, A.; Sugiyama, T.; Supanitsky, D.; Suzuki, M.; Szabelska, B.; Szabelski, J.; Tajima, F.; Tajima, N.; Tajima, T.; Takahashi, Y.; Takami, H.; Takeda, M.; Takizawa, Y.; Tenzer, C.; Tibolla, O.; Tkachev, L.; Tokuno, H.; Tomida, T.; Tone, N.; Toscano, S.; Trillaud, F.; Tsenov, R.; Tsunesada, Y.; Tsuno, K.; Tymieniecka, T.; Uchihori, Y.; Unger, M.; Vaduvescu, O.; Valdés-Galicia, J. F.; Vallania, P.; Valore, L.; Vankova, G.; Vigorito, C.; Villaseñor, L.; von Ballmoos, P.; Wada, S.; Watanabe, J.; Watanabe, S.; Watts, J.; Weber, M.; Weiler, T. J.; Wibig, T.; Wiencke, L.; Wille, M.; Wilms, J.; Włodarczyk, Z.; Yamamoto, T.; Yamamoto, Y.; Yang, J.; Yano, H.; Yashin, I. V.; Yonetoku, D.; Yoshida, K.; Yoshida, S.; Young, R.; Zotov, M. Yu.; Zuccaro Marchi, A.

    2015-11-01

    The JEM-EUSO telescope will be, after calibration, a very accurate instrument which yields the number of received photons from the number of measured photo-electrons. The project is in phase A (demonstration of the concept) including already operating prototype instruments, i.e. many parts of the instrument have been constructed and tested. Calibration is a crucial part of the instrument and its use. The focal surface (FS) of the JEM-EUSO telescope will consist of about 5000 photo-multiplier tubes (PMTs), which have to be well calibrated to reach the required accuracy in reconstructing the air-shower parameters. The optics system consists of 3 plastic Fresnel (double-sided) lenses of 2.5 m diameter. The aim of the calibration system is to measure the efficiencies (transmittances) of the optics and absolute efficiencies of the entire focal surface detector. The system consists of 3 main components: (i) Pre-flight calibration devices on ground, where the efficiency and gain of the PMTs will be measured absolutely and also the transmittance of the optics will be. (ii) On-board relative calibration system applying two methods: a) operating during the day when the JEM-EUSO lid will be closed with small light sources on board. b) operating during the night, together with data taking: the monitoring of the background rate over identical sites. (iii) Absolute in-flight calibration, again, applying two methods: a) measurement of the moon light, reflected on high altitude, high albedo clouds. b) measurements of calibrated flashes and tracks produced by the Global Light System (GLS). Some details of each calibration method will be described in this paper.

  13. Is There a Clinical Role For Smartphone Sleep Apps? Comparison of Sleep Cycle Detection by a Smartphone Application to Polysomnography.

    PubMed

    Bhat, Sushanth; Ferraris, Ambra; Gupta, Divya; Mozafarian, Mona; DeBari, Vincent A; Gushway-Henry, Neola; Gowda, Satish P; Polos, Peter G; Rubinstein, Mitchell; Seidu, Huzaifa; Chokroverty, Sudhansu

    2015-07-15

    Several inexpensive, readily available smartphone apps that claim to monitor sleep are popular among patients. However, their accuracy is unknown, which limits their widespread clinical use. We therefore conducted this study to evaluate the validity of parameters reported by one such app, the Sleep Time app (Azumio, Inc., Palo Alto, CA, USA) for iPhones. Twenty volunteers with no previously diagnosed sleep disorders underwent in-laboratory polysomnography (PSG) while simultaneously using the app. Parameters reported by the app were then compared to those obtained by PSG. In addition, an epoch-by-epoch analysis was performed by dividing the PSG and app graph into 15-min epochs. There was no correlation between PSG and app sleep efficiency (r = -0.127, p = 0.592), light sleep percentage (r = 0.024, p = 0.921), deep sleep percentage (r = 0.181, p = 0.444) or sleep latency (rs = 0.384, p = 0.094). The app slightly and nonsignificantly overestimated sleep efficiency by 0.12% (95% confidence interval [CI] -4.9 to 5.1%, p = 0.962), significantly underestimated light sleep by 27.9% (95% CI 19.4-36.4%, p < 0.0001), significantly overestimated deep sleep by 11.1% (CI 4.7-17.4%, p = 0.008) and significantly overestimated sleep latency by 15.6 min (CI 9.7-21.6, p < 0.0001). Epochwise comparison showed low overall accuracy (45.9%) due to poor interstage discrimination, but high accuracy in sleep-wake detection (85.9%). The app had high sensitivity but poor specificity in detecting sleep (89.9% and 50%, respectively). Our study shows that the absolute parameters and sleep staging reported by the Sleep Time app (Azumio, Inc.) for iPhones correlate poorly with PSG. Further studies comparing app sleep-wake detection to actigraphy may help elucidate its potential clinical utility. A commentary on this article appears in this issue on page 695. © 2015 American Academy of Sleep Medicine.

  14. Population trends of binary near-Earth asteroids based on radar and lightcurves observations

    NASA Astrophysics Data System (ADS)

    Brozovic, Marina; Benner, Lance A. M.; Naidu, Shantanu P.; Taylor, Patrick A.; Busch, Michael W.; Margot, Jean-Luc; Nolan, Michael C.; Howell, Ellen S.; Springmann, Alessondra; Giorgini, Jon D.; Shepard, Michael K.; Magri, Christopher; Richardson, James E.; Rivera-Valentin, Edgard G.; Rodriguez-Ford, Linda A.; Zambrano Marin, Luisa Fernanda

    2016-10-01

    The Arecibo and Goldstone planetary radars are invaluable instruments for the discovery and characterization of binary and triple asteroids in the near-Earth asteroid (NEA) population. To date, 41 out of 56 known binaries and triples (~73% of the objects) have been discovered by radar and 49 of these multiple systems have been detected by radar. Their absolute magnitudes range from 12.4 for (1866) Sisyphus to 22.6 for 2015 TD144 and have a mean and rms dispersion of 18.1+-2.0. There is a pronounced decrease in the abundance of binaries for absolute magnitudes H>20. One of the smallest binaries, 1994 CJ1, with an absolute magnitude H=21.4, is also the most accessible binary for a spacecraft rendezvous. Among 365 NEAs with H<22 (corresponding to diameters larger than ~ 140 m) detected by radar since 1999, ~13% have at least one companion. Two triple systems are known, (15391) 2001 SN263 and (136617) 1994 CC, but this is probably an underestimate due to low signal to noise ratios (SNRs) for many of the binary radar detections. Taxonomic classes have been reported for 41 out of 56 currently known multiple systems and some trends are starting to emerge: at least 50% of multiple asteroid systems are S, Sq, Q, or Sk, and at least 20% are optically dark (C, B, P, or U). Thirteen V-class NEAs have been observed by radar and six of them are binaries. Curiously, a comparable number of E-class objects have been detected by radar, but none is known to be a binary.

  15. Test-Retest Reliability and Minimal Detectable Change of Randomized Dichotic Digits in Learning-Disabled Children: Implications for Dichotic Listening Training.

    PubMed

    Mahdavi, Mohammad Ebrahim; Pourbakht, Akram; Parand, Akram; Jalaie, Shohreh

    2018-03-01

    Evaluation of dichotic listening to digits is a common part of many studies for diagnosis and managing auditory processing disorders in children. Previous researchers have verified test-retest relative reliability of dichotic digits results in normal children and adults. However, detecting intervention-related changes in the ear scores after dichotic listening training requires information regarding trial-to-trial typical variation of individual ear scores that is estimated using indices of absolute reliability. Previous studies have not addressed absolute reliability of dichotic listening results. To compare the results of the Persian randomized dichotic digits test (PRDDT) and its relative and absolute indices of reliability between typical achieving (TA) and learning-disabled (LD) children. A repeated measures observational study. Fifteen LD children were recruited from a previously performed study with age range of 7-12 yr. The control group consisted of 15 TA schoolchildren with age range of 8-11 yr. The Persian randomized dichotic digits test was administered on the children under free recall condition in two test sessions 7-12 days apart. We compared the average of the ear scores and ear advantage between TA and LD children. Relative indices of reliability included Pearson's correlation and intraclass correlation (ICC 2,1 ) coefficients and absolute reliability was evaluated by calculation of standard error of measurement (SEM) and minimal detectable change (MDC) using the raw ear scores. The Pearson correlation coefficient indicated that in both groups of children the ear scores of test and retest sessions were strongly and positively (greater than +0.8) correlated. The ear scores showed excellent ICC coefficient of consistency (0.78-0.82) and fair to excellent ICC coefficient of absolute agreement (0.62-0.74) in TA children and excellent ICC coefficients of consistency and absolute agreement in LD children (0.76-0.87). SEM and SEM% of the ear scores in TA children were 1.46 and 1.44% for the right ear and 4.68 and 5.47% for the left ear. SEM and SEM% of the ear scores in LD children were 4.55 and 5.88% for the right ear to 7.56 and 12.81% for the left ear. MDC and MDC% of the ear scores in TA children varied from 4.03 and 3.99% for the right ear to 12.93 and 15.13% for the left ear. MDC and MDC% of the ear scores in LD children varied from 12.57 and 16.25% for the right ear to 20.89 and 35.39% for the left ear. The LD children indicated test-retest relative reliability as high as TA children in the ear scores measured by PRDDT. However, within-subject variations of the ear scores calculated by indices of absolute reliability were considerably higher in LD children versus TA children. The results of the current study could have implications for detecting real training-related changes in the ear scores. American Academy of Audiology

  16. On the Perceptual Subprocess of Absolute Pitch.

    PubMed

    Kim, Seung-Goo; Knösche, Thomas R

    2017-01-01

    Absolute pitch (AP) is the rare ability of musicians to identify the pitch of tonal sound without external reference. While there have been behavioral and neuroimaging studies on the characteristics of AP, how the AP is implemented in human brains remains largely unknown. AP can be viewed as comprising of two subprocesses: perceptual (processing auditory input to extract a pitch chroma) and associative (linking an auditory representation of pitch chroma with a verbal/non-verbal label). In this review, we focus on the nature of the perceptual subprocess of AP. Two different models on how the perceptual subprocess works have been proposed: either via absolute pitch categorization (APC) or based on absolute pitch memory (APM). A major distinction between the two views is that whether the AP uses unique auditory processing (i.e., APC) that exists only in musicians with AP or it is rooted in a common phenomenon (i.e., APM), only with heightened efficiency. We review relevant behavioral and neuroimaging evidence that supports each notion. Lastly, we list open questions and potential ideas to address them.

  17. On the Perceptual Subprocess of Absolute Pitch

    PubMed Central

    Kim, Seung-Goo; Knösche, Thomas R.

    2017-01-01

    Absolute pitch (AP) is the rare ability of musicians to identify the pitch of tonal sound without external reference. While there have been behavioral and neuroimaging studies on the characteristics of AP, how the AP is implemented in human brains remains largely unknown. AP can be viewed as comprising of two subprocesses: perceptual (processing auditory input to extract a pitch chroma) and associative (linking an auditory representation of pitch chroma with a verbal/non-verbal label). In this review, we focus on the nature of the perceptual subprocess of AP. Two different models on how the perceptual subprocess works have been proposed: either via absolute pitch categorization (APC) or based on absolute pitch memory (APM). A major distinction between the two views is that whether the AP uses unique auditory processing (i.e., APC) that exists only in musicians with AP or it is rooted in a common phenomenon (i.e., APM), only with heightened efficiency. We review relevant behavioral and neuroimaging evidence that supports each notion. Lastly, we list open questions and potential ideas to address them. PMID:29085275

  18. Determination of short chain carboxylic acids in vegetable oils and fats using ion exclusion chromatography electrospray ionization mass spectrometry.

    PubMed

    Viidanoja, Jyrki

    2015-02-27

    A new method for quantification of short chain C1-C6 carboxylic acids in vegetable oils and fats by employing Liquid Chromatography Mass Spectrometry (LC-MS) has been developed. The method requires minor sample preparation and applies non-conventional Electrospray Ionization (ESI) liquid phase chemistry. Samples are first dissolved in chloroform and then extracted using water that has been spiked with stable isotope labeled internal standards that are used for signal normalization and absolute quantification of selected acids. The analytes are separated using Ion Exclusion Chromatography (IEC) and detected with Electrospray Ionization Mass Spectrometry (ESI-MS) as deprotonated molecules. Prior to ionization the eluent that contains hydrochloric acid is modified post-column to ensure good ionization efficiency of the analytes. The averaged within run precision and between run precision were generally lower than 8%. The accuracy was between 85 and 115% for most of the analytes. The Lower Limit of Quantification (LLOQ) ranged from 0.006 to 7mg/kg. It is shown that this method offers good selectivity in cases where UV detection fails to produce reliable results. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. ViBe: a universal background subtraction algorithm for video sequences.

    PubMed

    Barnich, Olivier; Van Droogenbroeck, Marc

    2011-06-01

    This paper presents a technique for motion detection that incorporates several innovative mechanisms. For example, our proposed technique stores, for each pixel, a set of values taken in the past at the same location or in the neighborhood. It then compares this set to the current pixel value in order to determine whether that pixel belongs to the background, and adapts the model by choosing randomly which values to substitute from the background model. This approach differs from those based upon the classical belief that the oldest values should be replaced first. Finally, when the pixel is found to be part of the background, its value is propagated into the background model of a neighboring pixel. We describe our method in full details (including pseudo-code and the parameter values used) and compare it to other background subtraction techniques. Efficiency figures show that our method outperforms recent and proven state-of-the-art methods in terms of both computation speed and detection rate. We also analyze the performance of a downscaled version of our algorithm to the absolute minimum of one comparison and one byte of memory per pixel. It appears that even such a simplified version of our algorithm performs better than mainstream techniques.

  20. [Experimental studies of using real-time fluorescence quantitative PCR and RT-PCR to detect E6 and E7 genes of human papillomavirus type 16 in cervical carcinoma cell lines].

    PubMed

    Chen, Yue-yue; Peng, Zhi-lan; Liu, Shan-ling; He, Bing; Hu, Min

    2007-06-01

    To establish a method of using real-time fluorescence quantitative PCR and RT-PCR to detect the E6 and E7 genes of human papillomavirus type 16 (HPV-16). Plasmids containing HPV-16 E6 or E7 were used to generate absolute standard curves. Three cervical carcinoma cell lines CaSki, SiHa and HeLa were tested by real-time fluorescence quantitative PCR and RT-PCR analyses for the expressions of HPV-16 E6 and E7. The correlation coefficients of standard curves were larger than 0. 99, and the PCR efficiency was more than 90%. The relative levels of HPV-16 E6 and E7 DNA and RNA were CaSki>SiHa>HeLa cell. HPV-16 E6 and E7 quantum by real-time fluorescence quantitative PCR and RT-PCR analyses may serve as a reliable and sensitive tool. This study provides the possibility of further researches on the relationship between HPV-16 E6 or E7 copy number and cervical carcinoma.

  1. Reaction πN → ππN near threshold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frlez, Emil

    1993-11-01

    The LAMPF E1179 experiment used the π 0 spectrometer and an array of charged particle range counters to detect and record π +π 0, π 0p, and π +π 0p coincidences following the reaction π +p → π 0π +p near threshold. The total cross sections for single pion production were measured at the incident pion kinetic energies 190, 200, 220, 240, and 260 MeV. Absolute normalizations were fixed by measuring π +p elastic scattering at 260 MeV. A detailed analysis of the π 0 detection efficiency was performed using cosmic ray calibrations and pion single charge exchange measurements with a 30 MeV π - beam. All published data on πN → ππN, including our results, are simultaneously fitted to yield a common chiral symmetry breaking parameter ξ =-0.25±0.10. The threshold matrix element |α 0(π 0π +p)| determined by linear extrapolation yields the value of the s-wave isospin-2 ππ scattering length αmore » $$2\\atop{0}$$(ππ) = -0.041±0.003 m$$-1\\atop{π}$$ -1, within the framework of soft-pion theory.« less

  2. Absolute atomic hydrogen densities in a radio frequency discharge measured by two-photon laser induced fluorescence imaging

    NASA Astrophysics Data System (ADS)

    Chérigier, L.; Czarnetzki, U.; Luggenhölscher, D.; Schulz-von der Gathen, V.; Döbele, H. F.

    1999-01-01

    Absolute atomic hydrogen densities were measured in the gaseous electronics conference reference cell parallel plate reactor by Doppler-free two-photon absorption laser induced fluorescence spectroscopy (TALIF) at λ=205 nm. The capacitively coupled radio frequency discharge was operated at 13.56 MHz in pure hydrogen under various input power and pressure conditions. The Doppler-free excitation technique with an unfocused laser beam together with imaging the fluorescence radiation by an intensified charge coupled device camera allows instantaneous spatial resolution along the radial direction. Absolute density calibration is obtained with the aid of a flow tube reactor and titration with NO2. The influence of spatial intensity inhomogenities along the laser beam and subsequent fluorescence are corrected by TALIF in xenon. A full mapping of the absolute density distribution between the electrodes was obtained. The detection limit for atomic hydrogen amounts to about 2×1018 m-3. The dissociation degree is of the order of a few percent.

  3. VUV photoionization cross sections of HO2, H2O2, and H2CO.

    PubMed

    Dodson, Leah G; Shen, Linhan; Savee, John D; Eddingsaas, Nathan C; Welz, Oliver; Taatjes, Craig A; Osborn, David L; Sander, Stanley P; Okumura, Mitchio

    2015-02-26

    The absolute vacuum ultraviolet (VUV) photoionization spectra of the hydroperoxyl radical (HO2), hydrogen peroxide (H2O2), and formaldehyde (H2CO) have been measured from their first ionization thresholds to 12.008 eV. HO2, H2O2, and H2CO were generated from the oxidation of methanol initiated by pulsed-laser-photolysis of Cl2 in a low-pressure slow flow reactor. Reactants, intermediates, and products were detected by time-resolved multiplexed synchrotron photoionization mass spectrometry. Absolute concentrations were obtained from the time-dependent photoion signals by modeling the kinetics of the methanol oxidation chemistry. Photoionization cross sections were determined at several photon energies relative to the cross section of methanol, which was in turn determined relative to that of propene. These measurements were used to place relative photoionization spectra of HO2, H2O2, and H2CO on an absolute scale, resulting in absolute photoionization spectra.

  4. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    NASA Astrophysics Data System (ADS)

    Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter

    2017-11-01

    Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  5. Mapping absolute tissue endogenous fluorophore concentrations with chemometric wide-field fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Xu, Zhang; Reilley, Michael; Li, Run; Xu, Min

    2017-06-01

    We report chemometric wide-field fluorescence microscopy for imaging the spatial distribution and concentration of endogenous fluorophores in thin tissue sections. Nonnegative factorization aided by spatial diversity is used to learn both the spectral signature and the spatial distribution of endogenous fluorophores from microscopic fluorescence color images obtained under broadband excitation and detection. The absolute concentration map of individual fluorophores is derived by comparing the fluorescence from "pure" fluorophores under the identical imaging condition following the identification of the fluorescence species by its spectral signature. This method is then demonstrated by characterizing the concentration map of endogenous fluorophores (including tryptophan, elastin, nicotinamide adenine dinucleotide, and flavin adenine dinucleotide) for lung tissue specimens. The absolute concentrations of these fluorophores are all found to decrease significantly from normal, perilesional, to cancerous (squamous cell carcinoma) tissue. Discriminating tissue types using the absolute fluorophore concentration is found to be significantly more accurate than that achievable with the relative fluorescence strength. Quantification of fluorophores in terms of the absolute concentration map is also advantageous in eliminating the uncertainties due to system responses or measurement details, yielding more biologically relevant data, and simplifying the assessment of competing imaging approaches.

  6. Optimal Design of the Absolute Positioning Sensor for a High-Speed Maglev Train and Research on Its Fault Diagnosis

    PubMed Central

    Zhang, Dapeng; Long, Zhiqiang; Xue, Song; Zhang, Junge

    2012-01-01

    This paper studies an absolute positioning sensor for a high-speed maglev train and its fault diagnosis method. The absolute positioning sensor is an important sensor for the high-speed maglev train to accomplish its synchronous traction. It is used to calibrate the error of the relative positioning sensor which is used to provide the magnetic phase signal. On the basis of the analysis for the principle of the absolute positioning sensor, the paper describes the design of the sending and receiving coils and realizes the hardware and the software for the sensor. In order to enhance the reliability of the sensor, a support vector machine is used to recognize the fault characters, and the signal flow method is used to locate the faulty parts. The diagnosis information not only can be sent to an upper center control computer to evaluate the reliability of the sensors, but also can realize on-line diagnosis for debugging and the quick detection when the maglev train is off-line. The absolute positioning sensor we study has been used in the actual project. PMID:23112619

  7. Absolute sensitivity calibration of an extreme ultraviolet spectrometer for tokamak measurements

    NASA Astrophysics Data System (ADS)

    Guirlet, R.; Schwob, J. L.; Meyer, O.; Vartanian, S.

    2017-01-01

    An extreme ultraviolet spectrometer installed on the Tore Supra tokamak has been calibrated in absolute units of brightness in the range 10-340 Å. This has been performed by means of a combination of techniques. The range 10-113 Å was absolutely calibrated by using an ultrasoft-X ray source emitting six spectral lines in this range. The calibration transfer to the range 113-182 Å was performed using the spectral line intensity branching ratio method. The range 182-340 Å was calibrated thanks to radiative-collisional modelling of spectral line intensity ratios. The maximum sensitivity of the spectrometer was found to lie around 100 Å. Around this wavelength, the sensitivity is fairly flat in a 80 Å wide interval. The spatial variations of sensitivity along the detector assembly were also measured. The observed trend is related to the quantum efficiency decrease as the angle of the incoming photon trajectories becomes more grazing.

  8. Absolute brightness temperature measurements at 3.5-mm wavelength. [of sun, Venus, Jupiter and Saturn

    NASA Technical Reports Server (NTRS)

    Ulich, B. L.; Rhodes, P. J.; Davis, J. H.; Hollis, J. M.

    1980-01-01

    Careful observations have been made at 86.1 GHz to derive the absolute brightness temperatures of the sun (7914 + or - 192 K), Venus (357.5 + or - 13.1 K), Jupiter (179.4 + or - 4.7 K), and Saturn (153.4 + or - 4.8 K) with a standard error of about three percent. This is a significant improvement in accuracy over previous results at millimeter wavelengths. A stable transmitter and novel superheterodyne receiver were constructed and used to determine the effective collecting area of the Millimeter Wave Observatory (MWO) 4.9-m antenna relative to a previously calibrated standard gain horn. The thermal scale was set by calibrating the radiometer with carefully constructed and tested hot and cold loads. The brightness temperatures may be used to establish an absolute calibration scale and to determine the antenna aperture and beam efficiencies of other radio telescopes at 3.5-mm wavelength.

  9. SRS-sensor 13C/12C isotops measurements for detecting Helicobacter Pylori

    NASA Astrophysics Data System (ADS)

    Grishkanich, Aleksandr; Chubchenko, Yan; Elizarov, Valentin; Zhevlakov, Aleksandr; Konopelko, Leonid

    2018-02-01

    We developed SRS-sensor 13C/12C isotops measurements detecting Helicobacter Pylori for medical diagnostics of human health. Measuring of absolute 13C/12C isotope amount ratios allows to explore the topical problems of the modern world, alcoholic beverages and tobacco, medical diagnostics of human health. SRS method is used to measure the ratio of carbon isotopes in the exhaled carbon dioxide, which is used to diagnose the human infection of Helicobacter pylori and the influence of the Helicobacter pylori bacterium on the occurrence of gastritis, gastric and duodenal ulcers. A method for the analysis of human infection with Helicobacter pylori was developed on the basis of measurements of the ratio of 13C / 12C carbon isotopes in human exhaled air with a high level of measurement accuracy. The article reviews the work in the field of provision comparability of absolute 13C/12C isotope amount ratios in the environment and food. The analysis of the technical and metrological characteristics of traditional and perspective instruments for measuring isotope ratios is presented. The provision of comparability of absolute 13C/12C isotope amount ratios is carried by gravimetrically prepared reference standards. The key features and emerging issues are discussed.

  10. Repeat Absolute and Relative Gravity Measurements for Geothermal Reservoir Monitoring in the Ogiri Geothermal Field, Southern Kyushu, Japan

    NASA Astrophysics Data System (ADS)

    Nishijima, J.; Umeda, C.; Fujimitsu, Y.; Takayama, J.; Hiraga, N.; Higuchi, S.

    2016-09-01

    Repeat hybrid microgravity measurements were conducted around the Ogiri Geothermal Field on the western slope of Kirishima volcano, southern Kyushu, Japan. This study was undertaken to detect the short-term gravity change caused by the temporary shutdown of production and reinjection wells for regular maintenance in 2011 and 2013. Repeat microgravity measurements were taken using an A-10 absolute gravimeter (Micro-g LaCoste) and CG-5 gravimeter (Scintrex) before and after regular maintenance. Both instruments had an accuracy of 10 μgal. The gravity stations were established at 27 stations (two stations for absolute measurements and 25 stations for relative measurements). After removal of noise effects (e.g., tidal movement, precipitation, shallow groundwater level changes), the residual gravity changes were subdivided into five types of response. We detected a gravity decrease (up to 20 μgal) in the reinjection area and a gravity increase (up to 30 μgal) in the production area 1 month after the temporary shutdown. Most of the gravity stations recovered after the maintenance. The temporal density changes in the geothermal reservoir were estimated based on these gravity changes.

  11. Integrated poly(dimethysiloxane) with an intrinsic nonfouling property approaching "absolute" zero background in immunoassays.

    PubMed

    Ma, Hongwei; Wu, Yuanzi; Yang, Xiaoli; Liu, Xing; He, Jianan; Fu, Long; Wang, Jie; Xu, Hongke; Shi, Yi; Zhong, Renqian

    2010-08-01

    The key to achieve a highly sensitive and specific protein microarray assay is to prevent nonspecific protein adsorption to an "absolute" zero level because any signal amplification method will simultaneously amplify signal and noise. Here, we develop a novel solid supporting material, namely, polymer coated initiator integrated poly(dimethysiloxane) (iPDMS), which was able to achieve such "absolute" zero (i.e., below the detection limit of instrument). The implementation of this iPDMS enables practical and high-quality multiplexed enzyme-linked immunosorbent assay (ELISA) of 11 tumor markers. This iPDMS does not need any blocking steps and only require mild washing conditions. It also uses on an average 8-fold less capture antibodies compared with the mainstream nitrocellulose (NC) film. Besides saving time and materials, iPDMS achieved a limit-of-detection (LOD) as low as 19 pg mL(-1), which is sufficiently low for most current clinical diagnostic applications. We expect to see an immediate impact of this iPDMS on the realization of the great potential of protein microarray in research and practical uses such as large scale and high-throughput screening, clinical diagnosis, inspection, and quarantine.

  12. Absolute Quantification of Norovirus Capsid Protein in Food, Water, and Soil Using Synthetic Peptides with Electrospray and MALDI Mass Spectrometry

    PubMed Central

    Hartmann, Erica M.; Colquhoun, David R.; Schwab, Kellogg J.; Halden, Rolf U.

    2015-01-01

    Norovirus infections are one of the most prominent public health problems of microbial origin in the U.S. and other industrialized countries. Surveillance is necessary to prevent secondary infection, confirm successful cleanup after outbreaks, and track the causative agent. Quantitative mass spectrometry, based on absolute quantitation with stable-isotope labeled peptides, is a promising tool for norovirus monitoring because of its speed, sensitivity, and robustness in the face of environmental inhibitors. In the current study, we present two new methods for the detection of the norovirus genogroup I capsid protein using electrospray and matrixassisted laser desorption/ionization (MALDI) mass spectrometry. The peptide TLDPIEVPLEDVR was used to quantify norovirus-like particles down to 500 attomoles with electrospray and 100 attomoles with MALDI. With MALDI, we also demonstrate a detection limit of 1 femtomole and a quantitative dynamic range of 5 orders of magnitude in the presence of an environmental matrix effect. Due to the rapid processing time and applicability to a wide range of environmental sample types (bacterial lysate, produce, milk, soil, and groundwater), mass spectrometry-based absolute quantitation has a strong potential for use in public health and environmental sciences. PMID:25603302

  13. Demonstration of a portable near-infrared CH4 detection sensor based on tunable diode laser absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Zheng, Chuan-Tao; Huang, Jian-Qiang; Ye, Wei-Lin; Lv, Mo; Dang, Jing-Min; Cao, Tian-Shu; Chen, Chen; Wang, Yi-Ding

    2013-11-01

    A portable near-infrared (NIR) CH4 detection sensor based on a distributed feedback (DFB) laser modulated at 1.654 μm is experimentally demonstrated. Intelligent temperature controller with an accuracy of -0.07 to +0.09 °C as well as a scan and modulation module generating saw-wave and cosine-wave signals are developed to drive the DFB laser, and a cost effective lock-in amplifier used to extract the second harmonic signal is integrated. Thorough experiments are carried out to obtain detection performances, including detection range, accuracy, stability and the minimum detection limit (MDL). Measurement results show that the absolute detection error relative to the standard value is less than 7% within the range of 0-100%, and the MDL is estimated to be about 11 ppm under an absorption length of 0.2 m and a noise level of 2 mVpp. Twenty-four hours monitoring on two gas samples (0.1% and 20%) indicates that the absolute errors are less than 7% and 2.5%, respectively, suggesting good long term stability. The sensor reveals competitive characteristics compared with other reported portable or handheld sensors. The developed sensor can also be used for the detection of other gases by adopting other DFB lasers with different center-wavelength using the same hardware and slightly modified software.

  14. Process and design considerations for high-efficiency solar cells

    NASA Technical Reports Server (NTRS)

    Rohati, A.; Rai-Choudhury, P.

    1985-01-01

    This paper shows that oxide surface passivation coupled with optimum multilayer anti-reflective coating can provide approx. 3% (absolute) improvement in solar cell efficiency. Use of single-layer AR coating, without passivation, gives cell efficiencies in the range of 15 to 15.5% on high-quality, 4 ohm-cm as well as 0.1 to 0.2 ohm-cm float-zone silicon. Oxide surface passivation alone raises the cell efficiency to or = 17%. An optimum double-layer AR coating on oxide-passivated cells provides an additional approx. 5 to 10% improvement over a single-layer AR-coated cell, resulting in cell efficiencies in excess of 18%. Experimentally observed improvements are supported by model calculations and an approach to or = 20% efficient cells is discussed.

  15. First identification of O,S-diethyl Thiocarbonate in Indian Cress absolute and odor evaluation of its synthesized homologues by GC-sniffing.

    PubMed

    Breme, Katharina; Guillamon, Nadine; Fernandez, Xavier; Tournayre, Pascal; Brevard, Hugues; Joulain, Daniel; Berdagué, Jean Louis; Meierhenrich, Uwe J

    2009-03-25

    Indian cress (Tropaeolum majus L.) absolute was studied by GC-olfactometry (VIDEO-Sniff method) in order to identify odor-active aroma compounds. Because of its fruity-sulfury odor note, a compound that has never been identified in plant extracts before stood out: O,S-diethyl thiocarbonate, present at 0.1% (percentage of the total GC/FID area) in the extract. GCxGC-TOFMS allowed for a clean mass spectrum to be obtained, and isolation by preparative GC followed by NMR studies allowed its identification. Here, we report on the first detection of O,S-diethyl thiocarbonate in Indian cress absolute by GC-olfactometry/VIDEO-Sniff and on its isolation and identification. The synthesis and odor evaluation of its homologues are presented.

  16. Luminescence of powdered uranium glasses

    NASA Technical Reports Server (NTRS)

    Eubanks, A. G.; Mcgarrity, J. M.; Silverman, J.

    1974-01-01

    Measurement of cathodoluminescence and photoluminescence efficiencies in powdered borosilicate glasses having different particle size and different uranium content. Excitation with 100 to 350 keV electrons and with 253.7 nm light was found to produce identical absolute radiant exitance spectra in powdered samples. The most efficient glass was one containing 29.4 wt% B2O3, 58.8 wt% SiO2, 9.8 wt% Na2O and 2.0 wt% UO2.

  17. Advanced Radioisotope Power Systems Segmented Thermoelectric Research

    NASA Technical Reports Server (NTRS)

    Caillat, Thierry

    2004-01-01

    Flight times are long; - Need power systems with >15 years life. Mass is at an absolute premium; - Need power systems with high specific power and scalability. 3 orders of magnitude reduction in solar irradiance from Earth to Pluto. Nuclear power sources preferable. The Overall objective is to develop low mass, high efficiency, low-cost Advanced Radioisotope Power System with double the Specific Power and Efficiency over state-of-the-art Radioisotope Thermoelectric Generators (RTGs).

  18. Structured physician order entry for trauma CT: value in improving clinical information transfer and billing efficiency.

    PubMed

    Wortman, Jeremy R; Goud, Asha; Raja, Ali S; Marchello, Dana; Sodickson, Aaron

    2014-12-01

    The purpose of this study was to measure the effects of use of a structured physician order entry system for trauma CT on the communication of clinical information and on coding practices and reimbursement efficiency. This study was conducted between April 1, 2011, and January 14, 2013, at a level I trauma center with 59,000 annual emergency department visits. On March 29, 2012, a structured order entry system was implemented for head through pelvis trauma CT, so-called pan-scan CT. This study compared the following factors before and after implementation: communication of clinical signs and symptoms and mechanism of injury, primary International Classification of Diseases, 9th revision, Clinical Modification (ICD-9-CM) code category, success of reimbursement, and time required for successful reimbursement for the examination. Chi-square statistics were used to compare all categoric variables before and after the intervention, and the Wilcoxon rank sum test was used to compare billing cycle times. A total of 457 patients underwent pan-scan CT in 2734 distinct examinations. After the intervention, there was a 62% absolute increase in requisitions containing clinical signs or symptoms (from 0.4% to 63%, p<0.0001) and a 99% absolute increase in requisitions providing mechanism of injury (from 0.4% to 99%, p<0.0001). There was a 19% absolute increase in primary ICD-9-CM codes representing clinical signs or symptoms (from 2.9% to 21.8%, p<0.0001), and a 7% absolute increase in reimbursement success for examinations submitted to insurance carriers (from 83.0% to 89.7%, p<0.0001). For reimbursed studies, there was a 14.7-day reduction in mean billing cycle time (from 68.4 days to 53.7 days, p=0.008). Implementation of structured physician order entry for trauma CT was associated with significant improvement in the communication of clinical history to radiologists. The improvement was also associated with changes in coding practices, greater billing efficiency, and an increase in reimbursement success.

  19. Calibration of the Auger Fluorescence Telescopes

    NASA Astrophysics Data System (ADS)

    Klages, H.; Pierre Auger Observatory Collaboration

    Thirty fluorescence telescopes in four stations will overlook the detector array of the southern hemisphere experiment of the Pierre Auger project. The main aim of these telescopes is tracking of EHE air showers, measurement of the longitudinal shower development (Xmax) and determination of the absolute energy of EHE events. A telescope camera contains 440 PMTs each covering a 1.5 x 1.5 degree pixel of the sky. The response of every pixel is converted into the number of charged particles at the observed part of the shower. This reconstruction includes the shower/observer geometry and the details of the atmospheric photon production and transport. The remaining experimental task is to convert the ADC counts of the camera pixel electronics into the light flux entering the Schmidt aperture. Three types of calibration and control are necessary : a) Monitoring of time dependent variations has to be performed for all parts of the optics and for all pixels frequently. Common illumination for all pixels of a camera allows the detection of individual deviations. Properties of windows, filters and mirrors have to be measured separately. b) Differences in pixel-to-pixel efficiency are mainly due to PMT gain and to differences in effective area (camera shadow, mirror size limits). Homogeneous and isotropic illumination will enable cross calibration. c) An absolute calibration has to be performed once in a while using trusted light monitors. The calibration methods used for the Pierre Auger FD telescopes in Argentina are discussed.

  20. Spot measurement of heart rate based on morphology of PhotoPlethysmoGraphic (PPG) signals.

    PubMed

    Madhan Mohan, P; Nagarajan, V; Vignesh, J C

    2017-02-01

    Due to increasing health consciousness among people, it is imperative to have low-cost health care devices to measure the vital parameters like heart rate and arterial oxygen saturation (SpO 2 ). In this paper, an efficient heart rate monitoring algorithm based on the morphology of photoplethysmography (PPG) signals to measure the spot heart rate (HR) and its real-time implementation is proposed. The algorithm does pre-processing and detects the onsets and systolic peaks of the PPG signal to estimate the heart rate of the subject. Since the algorithm is based on the morphology of the signal, it works well when the subject is not moving, which is a typical test case. So, this algorithm is developed mainly to measure the heart rate at on-demand applications. Real-time experimental results indicate the heart rate accuracy of 99.5%, mean absolute percentage error (MAPE) of 1.65%, mean absolute error (MAE) of 1.18 BPM and reference closeness factor (RCF) of 0.988. The results further show that the average response time of the algorithm to give the spot HR is 6.85 s, so that the users need not wait longer to see their HR. The hardware implementation results show that the algorithm only requires 18 KBytes of total memory and runs at high speed with 0.85 MIPS. So, this algorithm can be targeted to low-cost embedded platforms.

  1. First-principles investigation of CO adsorption on pristine, C-doped and N-vacancy defected hexagonal AlN nanosheets

    NASA Astrophysics Data System (ADS)

    Ouyang, Tianhong; Qian, Zhao; Ahuja, Rajeev; Liu, Xiangfa

    2018-05-01

    The optimized atomic structures, energetics and electronic structures of toxic gas CO adsorption systems on pristine, C-doped and N-vacancy defected h-AlN nanosheets respectively have been investigated using Density functional theory (DFT-D2 method) to explore their potential gas detection or sensing capabilities. It is found that both the C-doping and the N-vacancy defect improve the CO adsorption energies of AlN nanosheet (from pure -3.847 eV to -5.192 eV and -4.959 eV). The absolute value of the system band gap change induced by adsorption of CO can be scaled up to 2.558 eV or 1.296 eV after C-doping or N-vacancy design respectively, which is evidently larger than the value of 0.350 eV for pristine material and will benefit the robustness of electronic signals in potential gas detection. Charge transfer mechanisms between CO and the AlN nanosheet have been presented by the Bader charge and differential charge density analysis to explore the deep origin of the underlying electronic structure changes. This theoretical study is proposed to predict and understand the CO adsorption properties of the pristine and defected h-AlN nanosheets and would help to guide experimentalists to develop better AlN-based two-dimensional materials for efficient gas detection or sensing applications in the future.

  2. The 200 MeV Pi+ induced single-nucleon removal from 24Mg

    NASA Technical Reports Server (NTRS)

    Joyce, Donald; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; hide

    1985-01-01

    Nuclear gamma-rays in coincidence with outgoing pions or protons following single nucleon removal from Mg-24 by 200 MeV pions (+) were detected with Ge(Li) detectors. Differential cross sections are reported for gamma-rays from the first excited mirror states of Na-23 and Mg-23 in coincidence with positive pions or protons detected in particle telescopes at 30, 60, 90, 120, and 150 deg; angle-integrated absolute cross sections and cross section ratios are calculated. These results are compared with the predictions of a Pauli-blocked plane-wave impulse approximation (PWIA) and the intranuclear cascade (INC) and nucleon charge exchange (NCX) reaction models. The PWIA and the INC calculations generally agree with the angular dependence of the experimental results but not the absolute magnitude. The NCX calculation does not reproduce the observed cross section charge ratios.

  3. Digital PCR provides absolute quantitation of viral load for an occult RNA virus.

    PubMed

    White, Richard Allen; Quake, Stephen R; Curr, Kenneth

    2012-01-01

    Using a multiplexed LNA-based Taqman assay, RT-digital PCR (RT-dPCR) was performed in a prefabricated microfluidic device that monitored absolute viral load in native and immortalized cell lines, overall precision of detection, and the absolute detection limit of an occult RNA virus GB Virus Type C (GBV-C). RT-dPCR had on average a 10% lower overall coefficient of variation (CV, a measurement of precision) for viral load testing than RT-qPCR and had a higher overall detection limit, able to quantify as low as three 5'-UTR molecules of GBV-C genome. Two commercial high-yield in vitro transcription kits (T7 Ribomax Express by Promega and Ampliscribe T7 Flash by Epicentre) were compared to amplify GBV-C RNA genome with T7-mediated amplification. The Ampliscribe T7 Flash outperformed the T7 Ribomax Express in yield of full-length GBV-C RNA genome. THP-1 cells (a model of monocytic derived cells) were transfected with GBV-C, yielding infectious virions that replicated over a 120h time course and could be infected directly. This study provides the first evidence of GBV-C replication in monocytic derived clonal cells. Thus far, it is the only study using a microfluidic device that measures directly viral load of mammalian RNA virus in a digital format without need for a standard curve. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Galaxy clusters in the SDSS Stripe 82 based on photometric redshifts

    DOE PAGES

    Durret, F.; Adami, C.; Bertin, E.; ...

    2015-06-10

    Based on a recent photometric redshift galaxy catalogue, we have searched for galaxy clusters in the Stripe ~82 region of the Sloan Digital Sky Survey by applying the Adami & MAzure Cluster FInder (AMACFI). Extensive tests were made to fine-tune the AMACFI parameters and make the cluster detection as reliable as possible. The same method was applied to the Millennium simulation to estimate our detection efficiency and the approximate masses of the detected clusters. Considering all the cluster galaxies (i.e. within a 1 Mpc radius of the cluster to which they belong and with a photoz differing by less thanmore » 0.05 from that of the cluster), we stacked clusters in various redshift bins to derive colour-magnitude diagrams and galaxy luminosity functions (GLFs). For each galaxy with absolute magnitude brighter than -19.0 in the r band, we computed the disk and spheroid components by applying SExtractor, and by stacking clusters we determined how the disk-to-spheroid flux ratio varies with cluster redshift and mass. We also detected 3663 clusters in the redshift range 0.1513 and a few 10 14 solar masses. Furthermore, by stacking the cluster galaxies in various redshift bins, we find a clear red sequence in the (g'-r') versus r' colour-magnitude diagrams, and the GLFs are typical of clusters, though with a possible contamination from field galaxies. The morphological analysis of the cluster galaxies shows that the fraction of late-type to early-type galaxies shows an increase with redshift (particularly in high mass clusters) and a decrease with detection level, i.e. cluster mass. From the properties of the cluster galaxies, the majority of the candidate clusters detected here seem to be real clusters with typical cluster properties.« less

  5. Galaxy clusters in the SDSS Stripe 82 based on photometric redshifts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durret, F.; Adami, C.; Bertin, E.

    Based on a recent photometric redshift galaxy catalogue, we have searched for galaxy clusters in the Stripe ~82 region of the Sloan Digital Sky Survey by applying the Adami & MAzure Cluster FInder (AMACFI). Extensive tests were made to fine-tune the AMACFI parameters and make the cluster detection as reliable as possible. The same method was applied to the Millennium simulation to estimate our detection efficiency and the approximate masses of the detected clusters. Considering all the cluster galaxies (i.e. within a 1 Mpc radius of the cluster to which they belong and with a photoz differing by less thanmore » 0.05 from that of the cluster), we stacked clusters in various redshift bins to derive colour-magnitude diagrams and galaxy luminosity functions (GLFs). For each galaxy with absolute magnitude brighter than -19.0 in the r band, we computed the disk and spheroid components by applying SExtractor, and by stacking clusters we determined how the disk-to-spheroid flux ratio varies with cluster redshift and mass. We also detected 3663 clusters in the redshift range 0.1513 and a few 10 14 solar masses. Furthermore, by stacking the cluster galaxies in various redshift bins, we find a clear red sequence in the (g'-r') versus r' colour-magnitude diagrams, and the GLFs are typical of clusters, though with a possible contamination from field galaxies. The morphological analysis of the cluster galaxies shows that the fraction of late-type to early-type galaxies shows an increase with redshift (particularly in high mass clusters) and a decrease with detection level, i.e. cluster mass. From the properties of the cluster galaxies, the majority of the candidate clusters detected here seem to be real clusters with typical cluster properties.« less

  6. Detectability of thermal neutrinos from binary neutron-star mergers and implications for neutrino physics

    NASA Astrophysics Data System (ADS)

    Kyutoku, Koutarou; Kashiyama, Kazumi

    2018-05-01

    We propose a long-term strategy for detecting thermal neutrinos from the remnant of binary neutron-star mergers with a future M-ton water-Cherenkov detector such as Hyper-Kamiokande. Monitoring ≳2500 mergers within ≲200 Mpc , we may be able to detect a single neutrino with a human time-scale operation of ≈80 Mtyears for the merger rate of 1 Mpc-3 Myr-1 , which is slightly lower than the median value derived by the LIGO-Virgo Collaboration with GW170817. Although the number of neutrino events is minimal, contamination from other sources of neutrinos can be reduced efficiently to ≈0.03 by analyzing only ≈1 s after each merger identified with gravitational-wave detectors if gadolinium is dissolved in the water. The contamination may be reduced further to ≈0.01 if we allow the increase of waiting time by a factor of ≈1.7 . The detection of even a single neutrino can pin down the energy scale of thermal neutrino emission from binary neutron-star mergers and could strongly support or disfavor formation of remnant massive neutron stars. Because the dispersion relation of gravitational waves is now securely constrained to that of massless particles with a corresponding limit on the graviton mass of ≲10-22 eV /c2 by binary black-hole mergers, the time delay of a neutrino from gravitational waves can be used to put an upper limit of ≲O (10 ) meV /c2 on the absolute neutrino mass in the lightest eigenstate. Large neutrino detectors will enhance the detectability, and, in particular, 5 Mt Deep-TITAND and 10 Mt MICA planned in the future will allow us to detect thermal neutrinos every ≈16 and 8 years, respectively, increasing the significance.

  7. Linking Comparisons of Absolute Gravimeters: A Proof of Concept for a new Global Absolute Gravity Reference System.

    NASA Astrophysics Data System (ADS)

    Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.

    2016-12-01

    Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.

  8. Metabolite concentrations, fluxes and free energies imply efficient enzyme usage

    DOE PAGES

    Park, Junyoung O.; Rubin, Sara A.; Xu, Yi -Fan; ...

    2016-05-02

    In metabolism, available free energy is limited and must be divided across pathway steps to maintain a negative Δ G throughout. For each reaction, Δ G is log proportional both to a concentration ratio (reaction quotient to equilibrium constant) and to a flux ratio (backward to forward flux). In this paper, we use isotope labeling to measure absolute metabolite concentrations and fluxes in Escherichia coli, yeast and a mammalian cell line. We then integrate this information to obtain a unified set of concentrations and Δ G for each organism. In glycolysis, we find that free energy is partitioned so asmore » to mitigate unproductive backward fluxes associated with Δ G near zero. Across metabolism, we observe that absolute metabolite concentrations and Δ G are substantially conserved and that most substrate (but not inhibitor) concentrations exceed the associated enzyme binding site dissociation constant ( K m or K i). Finally, the observed conservation of metabolite concentrations is consistent with an evolutionary drive to utilize enzymes efficiently given thermodynamic and osmotic constraints.« less

  9. Study of ground state optical transfer for ultracold alkali dimers

    NASA Astrophysics Data System (ADS)

    Bouloufa-Maafa, Nadia; Londono, Beatriz; Borsalino, Dimitri; Vexiau, Romain; Mahecha, Jorge; Dulieu, Olivier; Luc-Koenig, Eliane

    2013-05-01

    Control of molecular states by laser pulses offer promising potential applications. The manipulation of molecules by external fields requires precise knowledge of the molecular structure. Our motivation is to perform a detailed analysis of the spectroscopic properties of alkali dimers, with the aim to determine efficient optical paths to form molecules in the absolute ground state and to determine the optimal parameters of the optical lattices where those molecules are manipulated to avoid losses by collisions. To this end, we use state of the art molecular potentials, R-dependent spin-orbit coupling and transition dipole moment to perform our calculations. R-dependent SO coupling are of crucial importance because the transitions occur at internuclear distances where they are affected by this R-dependence. Efficient schemes to transfer RbCs, KRb and KCs to the absolute ground state as well as the optimal parameters of the optical lattices will be presented. This work was supported in part by ``Triangle de la Physique'' under contract 2008-007T-QCCM (Quantum Control of Cold Molecules).

  10. [Comparison study on sampling methods of Oncomelania hupensis snail survey in marshland schistosomiasis epidemic areas in China].

    PubMed

    An, Zhao; Wen-Xin, Zhang; Zhong, Yao; Yu-Kuan, Ma; Qing, Liu; Hou-Lang, Duan; Yi-di, Shang

    2016-06-29

    To optimize and simplify the survey method of Oncomelania hupensis snail in marshland endemic region of schistosomiasis and increase the precision, efficiency and economy of the snail survey. A quadrate experimental field was selected as the subject of 50 m×50 m size in Chayegang marshland near Henghu farm in the Poyang Lake region and a whole-covered method was adopted to survey the snails. The simple random sampling, systematic sampling and stratified random sampling methods were applied to calculate the minimum sample size, relative sampling error and absolute sampling error. The minimum sample sizes of the simple random sampling, systematic sampling and stratified random sampling methods were 300, 300 and 225, respectively. The relative sampling errors of three methods were all less than 15%. The absolute sampling errors were 0.221 7, 0.302 4 and 0.047 8, respectively. The spatial stratified sampling with altitude as the stratum variable is an efficient approach of lower cost and higher precision for the snail survey.

  11. Optical Johnson noise thermometry

    DOEpatents

    Shepard, Robert L.; Blalock, Theron V.; Roberts, Michael J.; Maxey, Lonnie C.

    1992-01-01

    Method and device for direct, non-contact temperature measure of a body. A laser beam is reflected from the surface of the body and detected along with the Planck radiation. The detected signal is analyzed using signal correlation technique to generate an output signal proportional to the Johnson noise introduced into the reflected laser beam as a direct measure of the absolute temperature of the body.

  12. Python Waveform Cross-Correlation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Templeton, Dennise

    PyWCC is a tool to compute seismic waveform cross-correlation coefficients on single-component or multiple-component seismic data across a network of seismic sensors. PyWCC compares waveform data templates with continuous seismic data, associates the resulting detections, identifies the template with the highest cross-correlation coefficient, and outputs a catalog of detections above a user-defined absolute cross-correlation threshold value.

  13. Restrictions on linear heat capacities from Joule-Brayton maximum-work cycle efficiency

    NASA Astrophysics Data System (ADS)

    Angulo-Brown, F.; Gonzalez-Ayala, Julian; Arias-Hernandez, L. A.

    2014-02-01

    This paper discusses the possibility of using the Joule-Brayton cycle to determine the accessible value range for the coefficients a and b of the heat capacity at constant pressure Cp, expressed as Cp=a+bT (with T the absolute temperature) by using the Carnot theorem. This is made for several gases which operate as the working fluids. Moreover, the landmark role of the Curzon-Ahlborn efficiency for this type of cycle is established.

  14. Hybrid Molecule-Nanocrystal Photon Upconversion Across the Visible and Near-Infrared

    DTIC Science & Technology

    2015-07-10

    applications in solar energy, biological imaging , and data storage. In this Letter, CdSe and PbSe semiconductor nanocrystals are combined with molecular...Goldschmidt, J. C. Absolute Upconversion Quantum Yield of β-NaYF4 Doped with Er3+ and External Quantum Efficiency of Upconverter Solar Cell Devices...C. Peak External Photocurrent Quantum Efficiency Exceeding 100% via MEG in a Quantum Dot Solar Cell . Science 2011, 334, 1530−1533. (37) Choi, J.-H

  15. Ultrasound virtual endoscopy: Polyp detection and reliability of measurement in an in vitro study with pig intestine specimens

    PubMed Central

    Liu, Jin-Ya; Chen, Li-Da; Cai, Hua-Song; Liang, Jin-Yu; Xu, Ming; Huang, Yang; Li, Wei; Feng, Shi-Ting; Xie, Xiao-Yan; Lu, Ming-De; Wang, Wei

    2016-01-01

    AIM: To present our initial experience regarding the feasibility of ultrasound virtual endoscopy (USVE) and its measurement reliability for polyp detection in an in vitro study using pig intestine specimens. METHODS: Six porcine intestine specimens containing 30 synthetic polyps underwent USVE, computed tomography colonography (CTC) and optical colonoscopy (OC) for polyp detection. The polyp measurement defined as the maximum polyp diameter on two-dimensional (2D) multiplanar reformatted (MPR) planes was obtained by USVE, and the absolute measurement error was analyzed using the direct measurement as the reference standard. RESULTS: USVE detected 29 (96.7%) of 30 polyps, remaining a 7-mm one missed. There was one false-positive finding. Twenty-six (89.7%) of 29 reconstructed images were clearly depicted, while 29 (96.7%) of 30 polyps were displayed on CTC with one false-negative finding. In OC, all the polyps were detected. The intraclass correlation coefficient was 0.876 (95%CI: 0.745-0.940) for measurements obtained with USVE. The pooled absolute measurement errors ± the standard deviations of the depicted polyps with actual sizes ≤ 5 mm, 6-9 mm, and ≥ 10 mm were 1.9 ± 0.8 mm, 0.9 ± 1.2 mm, and 1.0 ± 1.4 mm, respectively. CONCLUSION: USVE is reliable for polyp detection and measurement in in vitro study. PMID:27022217

  16. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples.

    PubMed

    Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-03-18

    Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems.

  17. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples

    PubMed Central

    Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-01-01

    Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems. PMID:26999129

  18. The metabolism of plant sterols is disturbed in postmenopausal women with coronary artery disease.

    PubMed

    Gylling, Helena; Hallikainen, Maarit; Rajaratnam, Radhakrishnan A; Simonen, Piia; Pihlajamäki, Jussi; Laakso, Markku; Miettinen, Tatu A

    2009-03-01

    In postmenopausal coronary artery disease (CAD) women, serum plant sterols are elevated. Thus, we investigated further whether serum plant sterols reflect absolute cholesterol metabolism in CAD as in other populations and whether the ABCG5 and ABCG8 genes, associated with plant sterol metabolism, were related to the risk of CAD. In free-living postmenopausal women with (n = 47) and without (n = 62) CAD, serum noncholesterol sterols including plant sterols were analyzed with gas-liquid chromatography, cholesterol absorption with peroral isotopes, absolute cholesterol synthesis with sterol balance technique, and bile acid synthesis with quantitating fecal bile acids. In CAD women, serum plant sterol ratios to cholesterol were 21% to 26% (P < .05) higher than in controls despite similar cholesterol absorption efficiency. Absolute cholesterol and bile acid synthesis were reduced. Only in controls were serum plant sterols related to cholesterol absorption (eg, sitosterol; in controls: r = 0.533, P < .001; in CAD: r = 0.296, P = not significant). However, even in CAD women, serum lathosterol (relative synthesis marker) and lathosterol-cholestanol (relative synthesis-absorption marker) were related to absolute synthesis and absorption percentage (P range from .05 to <.001) similarly to controls. Frequencies of the common polymorphisms of ABCG5 and ABCG8 genes did not differ between coronary and control women. In conclusion, plant sterol metabolism is disturbed in CAD women; so serum plant sterols only tended to reflect absolute cholesterol absorption. Other relative markers of cholesterol metabolism were related to the absolute ones in both groups. ABCG5 and ABCG8 genes were not associated with the risk of CAD.

  19. The Herschel Multi-Tiered Extragalactic Survey: SPIRE-mm Photometric Redshifts

    NASA Technical Reports Server (NTRS)

    Roseboom, I. G.; Ivison, R. J.; Greve, T. R.; Amblard, A.; Arumugam, V.; Auld, R.; Aussel, H.; Bethermin, M.; Blain, A.; Block, J.; hide

    2012-01-01

    We investigate the potential of submm-mm and submm-mm-radio photometric redshifts using a sample of mm-selected sources as seen at 250, 350 and 500 micron by the SPIRE instrument on Herschel. From a sample of 63 previously identified mm sources with reliable radio identifications in the Great Observatories Origins Deep Survey North and Lockman Hole North fields, 46 (73 per cent) are found to have detections in at least one SPIRE band. We explore the observed submm/mm color evolution with redshift, finding that the colors of mm sources are adequately described by a modified blackbody with constant optical depth Tau = (Nu/nu(sub 0))(exp Beta), where Beta = +1.8 and nu(sub 0) = c/100 micron. We find a tight correlation between dust temperature and IR luminosity. Using a single model of the dust temperature and IR luminosity relation, we derive photometric redshift estimates for the 46 SPIRE-detected mm sources. Testing against the 22 sources with known spectroscopic or good quality optical/near-IR photometric redshifts, we find submm/mm photometric redshifts offer a redshift accuracy of (absolute value of Delta sub (z))/(1 + z) = 0.16 (absolute value of Delta sub (z)) = 0.51). Including constraints from the radio-far-IR correlation, the accuracy is improved to (absolute value of Delta sub (z))/(1 + z) = 0.14 (((absolute value of Delta sub (z))) = 0.45). We estimate the redshift distribution of mm-selected sources finding a significant excess at Z > 3 when compared to approx 8S0 micron selected samples.

  20. Absolute optical extinction measurements of single nano-objects by spatial modulation spectroscopy using a white lamp

    NASA Astrophysics Data System (ADS)

    Billaud, Pierre; Marhaba, Salem; Grillet, Nadia; Cottancin, Emmanuel; Bonnet, Christophe; Lermé, Jean; Vialle, Jean-Louis; Broyer, Michel; Pellarin, Michel

    2010-04-01

    This article describes a high sensitivity spectrophotometer designed to detect the overall extinction of light by a single nanoparticle (NP) in the 10-4-10-5 relative range, using a transmission measurement configuration. We focus here on the simple and low cost scheme where a white lamp is used as a light source, permitting easy and broadband extinction measurements (300-900 nm). Using a microscope, in a confocal geometry, an increased sensitivity is reached thanks to a modulation of the NP position under the light spot combined with lock-in detection. Moreover, it is shown that this technique gives access to the absolute extinction cross-sections of the single NP provided that the incident electromagnetic field distribution experienced by the NP is accurately characterized. In this respect, an experimental procedure to characterize the light spot profile in the focal plane, using a reference NP as a probe, is also laid out. The validity of this approach is discussed and confirmed by comparing experimental intensity distributions to theoretical calculations taking into account the vector character of the tightly focused beam. The calibration procedure permitting to obtain the absolute extinction cross-section of the probed NP is then fully described. Finally, the force of the present technique is illustrated through selected examples concerning spherical and slightly elongated gold and silver NPs. Absolute extinction measurements are found to be in good consistency with the NP size and shape independently obtained from transmission electron microscopy, showing that spatial modulation spectroscopy is a powerful tool to get an optical fingerprint of the NP.

  1. Investigation of detection limits for diffuse optical tomography systems: II. Analysis of slab and cup geometry for breast imaging.

    PubMed

    Ziegler, Ronny; Brendel, Bernhard; Rinneberg, Herbert; Nielsen, Tim

    2009-01-21

    Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and model how detection sensitivity depends on breast compression and lesion fluorescence contrast. Our investigation shows that lesion detection is limited by relative noise in slab geometry and by absolute noise in cup geometry.

  2. ENVIORNMENTAL TECHNOLOGY VERIFICATION REPORT: ANEST IWATA CORPORATION LPH400-LV HVLP SPRAY GUN

    EPA Science Inventory

    This Enviornmental Technology Verification reports on the characteristics of a paint spray gun. The research showed that the spray gun provided absolute and relative increases in transfer efficiency over the base line and provided a reduction in the use of paint.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Surynek, J.; Mach, P.; Dressler, J.

    The administering of oxytetracycline, vitamin B/sub 12/, and folic acid is efficient in the recovery from postirradiation leucopenia in whole-body irradiated chicks. Oxytetracycline and vitamin B/sub 12/ combined influenced especially the number of heterophils, and the addition of folic acid resulted in a significant rise of the absolute lymphocyte count. (auth)

  4. Anchoring effects in the judgment of confidence: semantic or numeric priming?

    PubMed

    Carroll, Steven R; Petrusic, William M; Leth-Steensen, Craig

    2009-02-01

    Over the last decade, researchers have debated whether anchoring effects are the result of semantic or numeric priming. The present study tested both hypotheses. In four experiments involving a sensory detection task, participants first made a relative confidence judgment by deciding whether they were more or less confident than an anchor value in the correctness of their decision. Subsequently, they expressed an absolute level of confidence. In two of these experiments, the relative confidence anchor values represented the midpoints between the absolute confidence scale values, which were either explicitly numeric or semantic, nonnumeric representations of magnitude. In two other experiments, the anchor values were drawn from a scale modally different from that used to express the absolute confidence (i.e., nonnumeric and numeric, respectively, or vice versa). Regardless of the nature of the anchors, the mean confidence ratings revealed anchoring effects only when the relative and absolute confidence values were drawn from identical scales. Together, the results of these four experiments limit the conditions under which both numeric and semantic priming would be expected to lead to anchoring effects.

  5. Characterizing ICF Neutron Diagnostics on the nTOF line at SUNY Geneseo

    NASA Astrophysics Data System (ADS)

    Simone, Angela; Padalino, Stephen; Turner, Ethan; Ginnane, Mary Kate; Dubois, Natalie; Fletcher, Kurtis; Giordano, Michael; Lawson-Keister, Patrick; Harrison, Hannah; Visca, Hannah; Sangster, Craig; Regan, Sean

    2014-10-01

    Charged particle beams from the Geneseo 1.7 MV tandem Pelletron accelerator produce nuclear reactions that emit neutrons in the range of 0.5 to 17.9 MeV via the d(d,n)3He and 11B(d,n)12C reactions. The neutron energy and flux can be adjusted by controlling the accelerator beam current and potential. This adjustable neutron source makes it possible to calibrate ICF and HEDP neutron scintillator diagnostics. However, gamma rays which are often present during an accelerator-based calibration are difficult to differentiate from neutron signals in scintillators. To identify neutrons from gamma rays and to determine their energy, a permanent neutron time-of-flight (nTOF) line is being constructed. By detecting the scintillator signal in coincidence with an associated charged particle (ACP) produced in the reaction, the identity of the neutron can be known and its energy determined by time of flight. Using a 100% efficient surface barrier detector to count the ACPs, the absolute efficiency of the scintillator as a function of neutron energy can be determined. This is done by determining the ratio of the ACP counts in the singles spectrum to coincidence counts for matched solid angles of the SBD and scintillator. Funded in part by a LLE contract through the DOE.

  6. A novel bio-engineering approach to generate an eminent surface-functionalized template for selective detection of female sex pheromone of Helicoverpa armigera

    PubMed Central

    Moitra, Parikshit; Bhagat, Deepa; Pratap, Rudra; Bhattacharya, Santanu

    2016-01-01

    Plant pests exert serious effects on food production due to which the global crop yields are reduced by ~20–40 percent per year. Hence to meet the world’s food needs, loses of food due to crop pests must be reduced. Herein the silicon dioxide based MEMS devices are covalently functionalized for robust and efficient optical sensing of the female sex pheromones of the pests like Helicoverpa armigera for the first time in literature. The functionalized devices are also capable of selectively measuring the concentration of this pheromone at femtogram level which is much below the concentration of pheromone at the time of pest infestation in an agricultural field. Experiments are also performed in a confined region in the presence of male and female pests and tomato plants which directly mimics the real environmental conditions. Again the reversible use and absolutely trouble free transportation of these pheromone nanosensors heightens their potentials for commercial use. Overall, a novel and unique approach for the selective and reversible sensing of female sex pheromones of certain hazardous pests is reported herein which may be efficiently and economically carried forward from the research laboratory to the agricultural field. PMID:27892521

  7. Simulating coupled dynamics of a rigid-flexible multibody system and compressible fluid

    NASA Astrophysics Data System (ADS)

    Hu, Wei; Tian, Qiang; Hu, HaiYan

    2018-04-01

    As a subsequent work of previous studies of authors, a new parallel computation approach is proposed to simulate the coupled dynamics of a rigid-flexible multibody system and compressible fluid. In this approach, the smoothed particle hydrodynamics (SPH) method is used to model the compressible fluid, the natural coordinate formulation (NCF) and absolute nodal coordinate formulation (ANCF) are used to model the rigid and flexible bodies, respectively. In order to model the compressible fluid properly and efficiently via SPH method, three measures are taken as follows. The first is to use the Riemann solver to cope with the fluid compressibility, the second is to define virtual particles of SPH to model the dynamic interaction between the fluid and the multibody system, and the third is to impose the boundary conditions of periodical inflow and outflow to reduce the number of SPH particles involved in the computation process. Afterwards, a parallel computation strategy is proposed based on the graphics processing unit (GPU) to detect the neighboring SPH particles and to solve the dynamic equations of SPH particles in order to improve the computation efficiency. Meanwhile, the generalized-alpha algorithm is used to solve the dynamic equations of the multibody system. Finally, four case studies are given to validate the proposed parallel computation approach.

  8. Efficient estimation of ideal-observer performance in classification tasks involving high-dimensional complex backgrounds

    PubMed Central

    Park, Subok; Clarkson, Eric

    2010-01-01

    The Bayesian ideal observer is optimal among all observers and sets an absolute upper bound for the performance of any observer in classification tasks [Van Trees, Detection, Estimation, and Modulation Theory, Part I (Academic, 1968).]. Therefore, the ideal observer should be used for objective image quality assessment whenever possible. However, computation of ideal-observer performance is difficult in practice because this observer requires the full description of unknown, statistical properties of high-dimensional, complex data arising in real life problems. Previously, Markov-chain Monte Carlo (MCMC) methods were developed by Kupinski et al. [J. Opt. Soc. Am. A 20, 430(2003) ] and by Park et al. [J. Opt. Soc. Am. A 24, B136 (2007) and IEEE Trans. Med. Imaging 28, 657 (2009) ] to estimate the performance of the ideal observer and the channelized ideal observer (CIO), respectively, in classification tasks involving non-Gaussian random backgrounds. However, both algorithms had the disadvantage of long computation times. We propose a fast MCMC for real-time estimation of the likelihood ratio for the CIO. Our simulation results show that our method has the potential to speed up ideal-observer performance in tasks involving complex data when efficient channels are used for the CIO. PMID:19884916

  9. Cold atomic hydrogen in the inner galaxy

    NASA Technical Reports Server (NTRS)

    Dickey, J. M.; Garwood, R. W.

    1986-01-01

    The VLA is used to measure 21 cm absorption in directions with the absolute value of b less than 1 deg., the absolute value of 1 less than 25 deg. to probe the cool atomic gas in the inner galaxy. Abundant H I absorption is detected; typical lines are deep and narrow, sometimes blending in velocity with adjacent features. Unlike 21 cm emission not all allowed velocities are covered: large portions of the l-v diagram are optically thin. Although not similar to H I emission, the absorption shows a striking correspondence with CO emission in the inner galaxy: essentially every strong feature detected in one survey is seen in the other. The provisional conclusion is that in the inner galaxy most cool atomic gas is associated with molecular cloud complexes. There are few or no cold atomic clouds devoid of molecules in the inner galaxy, although these are common in the outer galaxy.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morley, Steven

    The PyForecastTools package provides Python routines for calculating metrics for model validation, forecast verification and model comparison. For continuous predictands the package provides functions for calculating bias (mean error, mean percentage error, median log accuracy, symmetric signed bias), and for calculating accuracy (mean squared error, mean absolute error, mean absolute scaled error, normalized RMSE, median symmetric accuracy). Convenience routines to calculate the component parts (e.g. forecast error, scaled error) of each metric are also provided. To compare models the package provides: generic skill score; percent better. Robust measures of scale including median absolute deviation, robust standard deviation, robust coefficient ofmore » variation and the Sn estimator are all provided by the package. Finally, the package implements Python classes for NxN contingency tables. In the case of a multi-class prediction, accuracy and skill metrics such as proportion correct and the Heidke and Peirce skill scores are provided as object methods. The special case of a 2x2 contingency table inherits from the NxN class and provides many additional metrics for binary classification: probability of detection, probability of false detection, false alarm ration, threat score, equitable threat score, bias. Confidence intervals for many of these quantities can be calculated using either the Wald method or Agresti-Coull intervals.« less

  11. The absolute threshold of cone vision

    PubMed Central

    Koeing, Darran; Hofer, Heidi

    2013-01-01

    We report measurements of the absolute threshold of cone vision, which has been previously underestimated due to sub-optimal conditions or overly strict subjective response criteria. We avoided these limitations by using optimized stimuli and experimental conditions while having subjects respond within a rating scale framework. Small (1′ fwhm), brief (34 msec), monochromatic (550 nm) stimuli were foveally presented at multiple intensities in dark-adapted retina for 5 subjects. For comparison, 4 subjects underwent similar testing with rod-optimized stimuli. Cone absolute threshold, that is, the minimum light energy for which subjects were just able to detect a visual stimulus with any response criterion, was 203 ± 38 photons at the cornea, ∼0.47 log units lower than previously reported. Two-alternative forced-choice measurements in a subset of subjects yielded consistent results. Cone thresholds were less responsive to criterion changes than rod thresholds, suggesting a limit to the stimulus information recoverable from the cone mosaic in addition to the limit imposed by Poisson noise. Results were consistent with expectations for detection in the face of stimulus uncertainty. We discuss implications of these findings for modeling the first stages of human cone vision and interpreting psychophysical data acquired with adaptive optics at the spatial scale of the receptor mosaic. PMID:21270115

  12. A modified QuEChERS method for the determination of some herbicides in yogurt and milk by high performance liquid chromatography.

    PubMed

    Li, Na; Lei, Lei; Nian, Li; Zhang, Rui; Wu, Shuting; Ren, Ruibing; Wang, Yeqiang; Zhang, Hanqi; Yu, Aimin

    2013-02-15

    A modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method was applied to the extraction of triazines and phenylureas from milk and yogurt. The herbicides was extracted by the mixture of ethyl acetate and n-hexane and cleaned by primary secondary amine (10mg/mL). The frozen-out centrifugation was applied to further remove fatty. The proposed method can achieve efficient extraction and cleanup. Some experimental parameters, such as extraction method, extraction solvent and adsorbent, pH of sample solution, extraction time and amount of primary secondary amine and sodium chloride were investigated and optimized. The precision and absolute recoveries of eight herbicides vary from 0.07 to 5.86% and from 78.9 to 99.9%, respectively. The detection limits for simeton, monuron, chlorotoluron, simetryne, atrazine, karmex, ametryne and propazine range from 0.15 to 0.35 ng/mL. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. [CORRECTION OF METABOLIC DISTURBANCES IN PATIENTS WITH PULMONARY TUBERCULOSIS AND CONCOMITANT DISEASES].

    PubMed

    2010-01-01

    Metabolic disturbances were corrected using the oral specialized formula Nutrien-phthisio (ZAO "Company Nutritec", Russia) in 53 patients with pulmonary tuberculosis and concomitant diseases. In the whole group, tuberculosis was first detected in 21 patients; 32 had a chronic process. Chemotherapy was discontinued in all the patients due to the intolerance phenomena caused by comorbidity (erosive gastritis, gastroduodenal peptic ulcer, hepatitis B and C, chronic pyelonephritis) in 24 patients, by adverse reactions in 19, and by a combination of both factors in 10. The criteria for objectively monitoring the efficiency of nutritional support (in combination with specific treatment) were body mass index, general blood analysis, by taking into account the percentage and absolute count of lymphocytes and the protein metabolism from the serum levels of total protein, albumin, and transferrin. The study determined clinical and laboratory indications for the use of Nutrien-phthisio and the favorable impact of nutritional support on the course of a tuberculous process and concomitant diseases.

  14. Mechanical regulation of plant growth and development

    NASA Technical Reports Server (NTRS)

    Mitchell, C. A.

    1984-01-01

    Soybean and eggplant grown and shaken in a greenhouse exhibited decreased internode length, internode diameter, leaf area, and fresh and dry weight of roots and shoots in much the same way as outdoor-exposed plants. Perhaps more important than decreased dimensions of plant parts resulting from periodic seismic treatment is the inhibition of photosynthetic productivity that accompanies this stress. Soybeam plants briefly shaken or rubbed twice daily experienced a decrease in relative as well as absolute growth rate compared to that of undisturbed controls. Growth dynamics analysis revealed that virtually all of the decline in relative growth rate (RGR) was due to a decline in net assimilation rate (NAR), but not in leaf area ratio (LAR). Lower NAR suggests that the stress-induced decrease in dry weight gain is due to a decline in photosynthetic efficiency. Possible effects on stomatal aperture was investigated by measuring rates of whole plant transpiration as a function of seismo-stress, and a transitory decrease followed by a gradual, partial recovery was detected.

  15. Dynamic ASXL1 Exon Skipping and Alternative Circular Splicing in Single Human Cells

    PubMed Central

    Natarajan, Sivaraman; Carter, Robert; Brown, Patrick O.

    2016-01-01

    Circular RNAs comprise a poorly understood new class of noncoding RNA. In this study, we used a combination of targeted deletion, high-resolution splicing detection, and single-cell sequencing to deeply probe ASXL1 circular splicing. We found that efficient circular splicing required the canonical transcriptional start site and inverted AluSx elements. Sequencing-based interrogation of isoforms after ASXL1 overexpression identified promiscuous linear splicing between all exons, with the two most abundant non-canonical linear products skipping the exons that produced the circular isoforms. Single-cell sequencing revealed a strong preference for either the linear or circular ASXL1 isoforms in each cell, and found the predominant exon skipping product is frequently co-expressed with its reciprocal circular isoform. Finally, absolute quantification of ASXL1 isoforms confirmed our findings and suggests that standard methods overestimate circRNA abundance. Taken together, these data reveal a dynamic new view of circRNA genesis, providing additional framework for studying their roles in cellular biology. PMID:27736885

  16. Constraints on the utility of MnO2 cartridge method for the extraction of radionuclides: A case study using 234Th

    USGS Publications Warehouse

    Baskaran, M.; Swarzenski, P.W.; Biddanda, B.A.

    2009-01-01

    [1] Large volume (102-103 L) seawater samples are routinely processed to investigate the partitioning of particle reactive radionuclides and Ra between solution and size-fractionated suspended particulate matter. One of the most frequently used methods to preconcentrate these nuclides from such large volumes involves extraction onto three filter cartridges (a prefilter for particulate species and two MnO2-coated filters for dissolved species) connected in series. This method assumes that the extraction efficiency is uniform for both MnO2-coated cartridges, that no dissolved species are removed by the prefilter, and that any adsorbed radionuclides are not desorbed from the MnO2-coated cartridges during filtration. In this study, we utilized 234Th-spiked coastal seawater and deionized water to address the removal of dissolved Th onto prefilters and MnO2-coated filter cartridges. Experimental results provide the first data that indicate (1) a small fraction of dissolved Th (<6%) can be removed by the prefilter cartridge; (2) a small fraction of dissolved Th (<5%) retained by the MnO2 surface can also be desorbed, which undermines the assumption of uniform extraction efficiency for Th; and (3) the absolute and relative extraction efficiencies can vary widely. These experiments provide insight on the variability of the extraction efficiency of MnO 2-coated filter cartridges by comparing the relative and absolute efficiencies and recommend the use of a constant efficiency on the combined activity from two filter cartridges connected in series for future studies of dissolved 234Th and other radionuclides in natural waters using sequential filtration/extraction methods. ?? 2009 by the American Geophysical Union.

  17. Synthetic Hounsfield units from spectral CT data

    NASA Astrophysics Data System (ADS)

    Bornefalk, Hans

    2012-04-01

    Beam-hardening-free synthetic images with absolute CT numbers that radiologists are used to can be constructed from spectral CT data by forming ‘dichromatic’ images after basis decomposition. The CT numbers are accurate for all tissues and the method does not require additional reconstruction. This method prevents radiologists from having to relearn new rules-of-thumb regarding absolute CT numbers for various organs and conditions as conventional CT is replaced by spectral CT. Displaying the synthetic Hounsfield unit images side-by-side with images reconstructed for optimal detectability for a certain task can ease the transition from conventional to spectral CT.

  18. Object detection system based on multimodel saliency maps

    NASA Astrophysics Data System (ADS)

    Guo, Ya'nan; Luo, Chongfan; Ma, Yide

    2017-03-01

    Detection of visually salient image regions is extensively applied in computer vision and computer graphics, such as object detection, adaptive compression, and object recognition, but any single model always has its limitations to various images, so in our work, we establish a method based on multimodel saliency maps to detect the object, which intelligently absorbs the merits of various individual saliency detection models to achieve promising results. The method can be roughly divided into three steps: in the first step, we propose a decision-making system to evaluate saliency maps obtained by seven competitive methods and merely select the three most valuable saliency maps; in the second step, we introduce heterogeneous PCNN algorithm to obtain three prime foregrounds; and then a self-designed nonlinear fusion method is proposed to merge these saliency maps; at last, the adaptive improved and simplified PCNN model is used to detect the object. Our proposed method can constitute an object detection system for different occasions, which requires no training, is simple, and highly efficient. The proposed saliency fusion technique shows better performance over a broad range of images and enriches the applicability range by fusing different individual saliency models, this proposed system is worthy enough to be called a strong model. Moreover, the proposed adaptive improved SPCNN model is stemmed from the Eckhorn's neuron model, which is skilled in image segmentation because of its biological background, and in which all the parameters are adaptive to image information. We extensively appraise our algorithm on classical salient object detection database, and the experimental results demonstrate that the aggregation of saliency maps outperforms the best saliency model in all cases, yielding highest precision of 89.90%, better recall rates of 98.20%, greatest F-measure of 91.20%, and lowest mean absolute error value of 0.057, the value of proposed saliency evaluation EHA reaches to 215.287. We deem our method can be wielded to diverse applications in the future.

  19. Seduction or Productivity: Repurposing the Promise of Technology

    ERIC Educational Resources Information Center

    Klein, William; Duffey, Suellynn

    2009-01-01

    In tight financial climates, emerging technologies loom as enticing options to administrators: efficient and cost-effective solutions to both operational and pedagogical problems. Disciplinary knowledge, frequently hailed as the pinnacle of cultural capital in the academy, does not hold absolute power in rhetorical situations in which the material…

  20. Detecting Lung and Colorectal Cancer Recurrence Using Structured Clinical/Administrative Data to Enable Outcomes Research and Population Health Management.

    PubMed

    Hassett, Michael J; Uno, Hajime; Cronin, Angel M; Carroll, Nikki M; Hornbrook, Mark C; Ritzwoller, Debra

    2017-12-01

    Recurrent cancer is common, costly, and lethal, yet we know little about it in community-based populations. Electronic health records and tumor registries contain vast amounts of data regarding community-based patients, but usually lack recurrence status. Existing algorithms that use structured data to detect recurrence have limitations. We developed algorithms to detect the presence and timing of recurrence after definitive therapy for stages I-III lung and colorectal cancer using 2 data sources that contain a widely available type of structured data (claims or electronic health record encounters) linked to gold-standard recurrence status: Medicare claims linked to the Cancer Care Outcomes Research and Surveillance study, and the Cancer Research Network Virtual Data Warehouse linked to registry data. Twelve potential indicators of recurrence were used to develop separate models for each cancer in each data source. Detection models maximized area under the ROC curve (AUC); timing models minimized average absolute error. Algorithms were compared by cancer type/data source, and contrasted with an existing binary detection rule. Detection model AUCs (>0.92) exceeded existing prediction rules. Timing models yielded absolute prediction errors that were small relative to follow-up time (<15%). Similar covariates were included in all detection and timing algorithms, though differences by cancer type and dataset challenged efforts to create 1 common algorithm for all scenarios. Valid and reliable detection of recurrence using big data is feasible. These tools will enable extensive, novel research on quality, effectiveness, and outcomes for lung and colorectal cancer patients and those who develop recurrence.

  1. In vivo visualization method by absolute blood flow velocity based on speckle and fringe pattern using two-beam multipoint laser Doppler velocimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kyoden, Tomoaki, E-mail: kyouden@nc-toyama.ac.jp; Naruki, Shoji; Akiguchi, Shunsuke

    Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensionalmore » space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.« less

  2. CT scan range estimation using multiple body parts detection: let PACS learn the CT image content.

    PubMed

    Wang, Chunliang; Lundström, Claes

    2016-02-01

    The aim of this study was to develop an efficient CT scan range estimation method that is based on the analysis of image data itself instead of metadata analysis. This makes it possible to quantitatively compare the scan range of two studies. In our study, 3D stacks are first projected to 2D coronal images via a ray casting-like process. Trained 2D body part classifiers are then used to recognize different body parts in the projected image. The detected candidate regions go into a structure grouping process to eliminate false-positive detections. Finally, the scale and position of the patient relative to the projected figure are estimated based on the detected body parts via a structural voting. The start and end lines of the CT scan are projected to a standard human figure. The position readout is normalized so that the bottom of the feet represents 0.0, and the top of the head is 1.0. Classifiers for 18 body parts were trained using 184 CT scans. The final application was tested on 136 randomly selected heterogeneous CT scans. Ground truth was generated by asking two human observers to mark the start and end positions of each scan on the standard human figure. When compared with the human observers, the mean absolute error of the proposed method is 1.2% (max: 3.5%) and 1.6% (max: 5.4%) for the start and end positions, respectively. We proposed a scan range estimation method using multiple body parts detection and relative structure position analysis. In our preliminary tests, the proposed method delivered promising results.

  3. Normal incidence spectrophotometer using high density transmission grating technology and highly efficiency silicon photodiodes for absolute solar EUV irradiance measurements

    NASA Technical Reports Server (NTRS)

    Ogawa, H. S.; Mcmullin, D.; Judge, D. L.; Korde, R.

    1992-01-01

    New developments in transmission grating and photodiode technology now make it possible to realize spectrometers in the extreme ultraviolet (EUV) spectral region (wavelengths less than 1000 A) which are expected to be virtually constant in their diffraction and detector properties. Time dependent effects associated with reflection gratings are eliminated through the use of free standing transmission gratings. These gratings together with recently developed and highly stable EUV photodiodes have been utilized to construct a highly stable normal incidence spectrophotometer to monitor the variability and absolute intensity of the solar 304 A line. Owing to its low weight and compactness, such a spectrometer will be a valuable tool for providing absolute solar irradiance throughout the EUV. This novel instrument will also be useful for cross-calibrating other EUV flight instruments and will be flown on a series of Hitchhiker Shuttle Flights and on SOHO. A preliminary version of this instrument has been fabricated and characterized, and the results are described.

  4. Fabrication and evaluation of magnetic activated carbon as adsorbent for ultrasonic assisted magnetic solid phase dispersive extraction of bisphenol A from milk prior to high performance liquid chromatographic analysis with ultraviolet detection.

    PubMed

    Filippou, Olga; Deliyanni, Eleni A; Samanidou, Victoria F

    2017-01-06

    In the present study, the impregnation of a micro - meso porous activated carbon with magnetite (Fe 3 O 4 ) was successfully achieved by sonication and the magnetic activated carbon prepared (Bmi) was evaluated as a new adsorbent for ultrasonic assisted magnetic solid phase dispersive extraction of Bisphenol A (BPA) from cow milk and human breast milk samples, prior to the determination by HPLC with UV detection. The prepared Bmi was characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The effect of pH on adsorption, initial concentration, contact time and desorption were studied. The main experimental parameters influencing extraction efficiency of BPA, such as type and amount of the adsorbent, sample amount, type of desorption solvent, time of adsorption and desorption, type of precipitation solvent, were investigated and optimized. Under the optimal extraction conditions the absolute recovery of BPA was 81% and 95% in cow milk and human breast milk samples, respectively. Good linearity was observed in the investigated concentration range of 2.5μgkg -1 -5000μgkg -1 (R 2 =0.9997). Limit of detection (LOD) was 0.75μgL -1 , which is in accordance with the specific migration limit (SML) established by the European Union, and limit of quantification (LOQ) was 2.5μgL -1 . Within-day and between-day recoveries ranged from 91.4% to 98.6% and 89.1% to 99.4% respectively and the RSDs were less than 3.7%. Due to the excellent magnetic behavior of Bmi the proposed method was shown to be simple and rapid. Besides these, this method is sensitive, low cost, efficient and environmentally friendly. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. A novel double-focusing time-of-flight mass spectrometer for absolute recoil ion cross sections measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigaud, L., E-mail: lsigaud@if.uff.br; Jesus, V. L. B. de; Ferreira, Natalia

    In this work, the inclusion of an Einzel-like lens inside the time-of-flight drift tube of a standard mass spectrometer coupled to a gas cell—to study ionization of atoms and molecules by electron impact—is described. Both this lens and a conical collimator are responsible for further focalization of the ions and charged molecular fragments inside the spectrometer, allowing a much better resolution at the time-of-flight spectra, leading to a separation of a single mass-to-charge unit up to 100 a.m.u. The procedure to obtain the overall absolute efficiency of the spectrometer and micro-channel plate detector is also discussed.

  6. A novel double-focusing time-of-flight mass spectrometer for absolute recoil ion cross sections measurements.

    PubMed

    Sigaud, L; de Jesus, V L B; Ferreira, Natalia; Montenegro, E C

    2016-08-01

    In this work, the inclusion of an Einzel-like lens inside the time-of-flight drift tube of a standard mass spectrometer coupled to a gas cell-to study ionization of atoms and molecules by electron impact-is described. Both this lens and a conical collimator are responsible for further focalization of the ions and charged molecular fragments inside the spectrometer, allowing a much better resolution at the time-of-flight spectra, leading to a separation of a single mass-to-charge unit up to 100 a.m.u. The procedure to obtain the overall absolute efficiency of the spectrometer and micro-channel plate detector is also discussed.

  7. Relative and absolute test-retest reliabilities of pressure pain threshold in patients with knee osteoarthritis.

    PubMed

    Srimurugan Pratheep, Neeraja; Madeleine, Pascal; Arendt-Nielsen, Lars

    2018-04-25

    Pressure pain threshold (PPT) and PPT maps are commonly used to quantify and visualize mechanical pain sensitivity. Although PPT's have frequently been reported from patients with knee osteoarthritis (KOA), the absolute and relative reliability of PPT assessments remain to be determined. Thus, the purpose of this study was to evaluate the test-retest relative and absolute reliability of PPT in KOA. For that purpose, intra- and interclass correlation coefficient (ICC) as well as the standard error of measurement (SEM) and the minimal detectable change (MDC) values within eight anatomical locations covering the most painful knee of KOA patients was measured. Twenty KOA patients participated in two sessions with a period of 2 weeks±3 days apart. PPT's were assessed over eight anatomical locations covering the knee and two remote locations over tibialis anterior and brachioradialis. The patients rated their maximum pain intensity during the past 24 h and prior to the recordings on a visual analog scale (VAS), and completed The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and PainDetect surveys. The ICC, SEM and MDC between the sessions were assessed. The ICC for the individual variability was expressed with coefficient of variance (CV). Bland-Altman plots were used to assess potential bias in the dataset. The ICC ranged from 0.85 to 0.96 for all the anatomical locations which is considered "almost perfect". CV was lowest in session 1 and ranged from 44.2 to 57.6%. SEM for comparison ranged between 34 and 71 kPa and MDC ranged between 93 and 197 kPa with a mean PPT ranged from 273.5 to 367.7 kPa in session 1 and 268.1-331.3 kPa in session 2. The analysis of Bland-Altman plot showed no systematic bias. PPT maps showed that the patients had lower thresholds in session 2, but no significant difference was observed for the comparison between the sessions for PPT or VAS. No correlations were seen between PainDetect and PPT and PainDetect and WOMAC. Almost perfect relative and absolute reliabilities were found for the assessment of PPT's for KOA patients. The present investigation implicates that PPT's is reliable for assessing pain sensitivity and sensitization in KOA patients.

  8. Evaluation of water-quality characteristics and sampling design for streams in North Dakota, 1970–2008

    USGS Publications Warehouse

    Galloway, Joel M.; Vecchia, Aldo V.; Vining, Kevin C.; Densmore, Brenda K.; Lundgren, Robert F.

    2012-01-01

    In response to the need to examine the large amount of historic water-quality data comprehensively across North Dakota and evaluate the efficiency of the State-wide sampling programs, a study was done by the U.S. Geological Survey in cooperation with the North Dakota State Water Commission and the North Dakota Department of Health to describe the water-quality data collected for the various programs and determine an efficient State-wide sampling design for monitoring future water-quality conditions. Although data collected for the North Dakota State Water Commission High-Low Sampling Program, the North Dakota Department of Health Ambient Water-Quality Network, and other projects and programs provide valuable information on the quality of water in streams in North Dakota, the objectives vary among the programs, some of the programs overlap spatially and temporally, and the various sampling designs may not be the most efficient or relevant to the objectives of the individual programs as they have changed through time. One objective of a State-wide sampling program was to evaluate ways to describe the spatial variability of water-quality conditions across the State in the most efficient manner. Weighted least-squares regression analysis was used to relate the average absolute difference between paired downstream and upstream concentrations, expressed as a percent of the average downstream concentration, to the average absolute difference in daily flow between the downstream and upstream pairs, expressed as a percent of the average downstream flow. The analysis showed that a reasonable spatial network would consist of including the most downstream sites in large basins first, followed by the next upstream site(s) that roughly bisect the downstream flows at the first sites, followed by the next upstream site(s) that roughly bisect flows for the second sites. Sampling sites to be included in a potential State-wide network were prioritized into 3 design levels: level 1 (highest priority), level 2 (second priority), and level 3 (third priority). Given the spatial distribution and priority designation (levels 1–3) of sites in the potential spatial network, the next consideration was to determine the appropriate temporal sampling frequency to use for monitoring future water-quality conditions. The time-series model used to detect concentration trends for this report also was used to evaluate sampling designs to monitor future water-quality trends. Sampling designs were evaluated with regard to their sensitivity to detect seasonal trends that occurred during three 4-month seasons—March through June, July through October, and November through February. For the 34 level-1 sites, samples would be collected for major ions, trace metals, nutrients, bacteria, and sediment eight times per year, with samples in January, April (2 samples),May, June, July, August, and October. For the 21 level-2 sites, samples would be collected for major ions, trace metals, and nutrients six times per year (January, April, May, June, August, and October), and for the 26 level-3 sites, samples would be collected for these constituents four times per year (April, June, August, and October).

  9. Third-Order Incremental Dual-Basis Set Zero-Buffer Approach: An Accurate and Efficient Way To Obtain CCSD and CCSD(T) Energies.

    PubMed

    Zhang, Jun; Dolg, Michael

    2013-07-09

    An efficient way to obtain accurate CCSD and CCSD(T) energies for large systems, i.e., the third-order incremental dual-basis set zero-buffer approach (inc3-db-B0), has been developed and tested. This approach combines the powerful incremental scheme with the dual-basis set method, and along with the new proposed K-means clustering (KM) method and zero-buffer (B0) approximation, can obtain very accurate absolute and relative energies efficiently. We tested the approach for 10 systems of different chemical nature, i.e., intermolecular interactions including hydrogen bonding, dispersion interaction, and halogen bonding; an intramolecular rearrangement reaction; aliphatic and conjugated hydrocarbon chains; three compact covalent molecules; and a water cluster. The results show that the errors for relative energies are <1.94 kJ/mol (or 0.46 kcal/mol), for absolute energies of <0.0026 hartree. By parallelization, our approach can be applied to molecules of more than 30 atoms and more than 100 correlated electrons with high-quality basis set such as cc-pVDZ or cc-pVTZ, saving computational cost by a factor of more than 10-20, compared to traditional implementation. The physical reasons of the success of the inc3-db-B0 approach are also analyzed.

  10. Standard-less analysis of Zircaloy clad samples by an instrumental neutron activation method

    NASA Astrophysics Data System (ADS)

    Acharya, R.; Nair, A. G. C.; Reddy, A. V. R.; Goswami, A.

    2004-03-01

    A non-destructive method for analysis of irregular shape and size samples of Zircaloy has been developed using the recently standardized k0-based internal mono standard instrumental neutron activation analysis (INAA). The samples of Zircaloy-2 and -4 tubes, used as fuel cladding in Indian boiling water reactors (BWR) and pressurized heavy water reactors (PHWR), respectively, have been analyzed. Samples weighing in the range of a few tens of grams were irradiated in the thermal column of Apsara reactor to minimize neutron flux perturbations and high radiation dose. The method utilizes in situ relative detection efficiency using the γ-rays of selected activation products in the sample for overcoming γ-ray self-attenuation. Since the major and minor constituents (Zr, Sn, Fe, Cr and/or Ni) in these samples were amenable to NAA, the absolute concentrations of all the elements were determined using mass balance instead of using the concentration of the internal mono standard. Concentrations were also determined in a smaller size Zircaloy-4 sample by irradiating in the core position of the reactor to validate the present methodology. The results were compared with literature specifications and were found to be satisfactory. Values of sensitivities and detection limits have been evaluated for the elements analyzed.

  11. Improved electron probe microanalysis of trace elements in quartz

    USGS Publications Warehouse

    Donovan, John J.; Lowers, Heather; Rusk, Brian G.

    2011-01-01

    Quartz occurs in a wide range of geologic environments throughout the Earth's crust. The concentration and distribution of trace elements in quartz provide information such as temperature and other physical conditions of formation. Trace element analyses with modern electron-probe microanalysis (EPMA) instruments can achieve 99% confidence detection of ~100 ppm with fairly minimal effort for many elements in samples of low to moderate average atomic number such as many common oxides and silicates. However, trace element measurements below 100 ppm in many materials are limited, not only by the precision of the background measurement, but also by the accuracy with which background levels are determined. A new "blank" correction algorithm has been developed and tested on both Cameca and JEOL instruments, which applies a quantitative correction to the emitted X-ray intensities during the iteration of the sample matrix correction based on a zero level (or known trace) abundance calibration standard. This iterated blank correction, when combined with improved background fit models, and an "aggregate" intensity calculation utilizing multiple spectrometer intensities in software for greater geometric efficiency, yields a detection limit of 2 to 3 ppm for Ti and 6 to 7 ppm for Al in quartz at 99% t-test confidence with similar levels for absolute accuracy.

  12. Synergistic Combination of Unquenching and Plasmonic Fluorescence Enhancement in Fluorogenic Nucleic Acid Hybridization Probes.

    PubMed

    Vietz, Carolin; Lalkens, Birka; Acuna, Guillermo P; Tinnefeld, Philip

    2017-10-11

    Fluorogenic nucleic acid hybridization probes are widely used for detecting and quantifying nucleic acids. The achieved sensitivity strongly depends on the contrast between a quenched closed form and an unquenched opened form with liberated fluorescence. So far, this contrast was improved by improving the quenching efficiency of the closed form. In this study, we modularly combine these probes with optical antennas used for plasmonic fluorescence enhancement and study the effect of the nanophotonic structure on the fluorescence of the quenched and the opened form. As quenched fluorescent dyes are usually enhanced more by fluorescence enhancement, a detrimental reduction of the contrast between closed and opened form was anticipated. In contrast, we could achieve a surprising increase of the contrast with full additivity of quenching of the dark form and fluorescence enhancement of the bright form. Using single-molecule experiments, we demonstrate that the additivity of the two mechanisms depends on the perfect quenching in the quenched form, and we delineate the rules for new nucleic acid probes for enhanced contrast and absolute brightness. Fluorogenic hybridization probes optimized not only for quenching but also for the brightness of the open form might find application in nucleic acid assays with PCR avoiding detection schemes.

  13. Accountability, efficiency, and the "bottom line" in non-profit organizations.

    PubMed

    Cutt, J

    1982-01-01

    Financial reporting by non-profit organizations deals only with accountability for propriety and regularity, and ignores output measurement. The development of output measures of a physical or index nature offers a means of relating dollar costs to output in the form of cost-efficiency or cost-effectiveness measures, but does not provide any measure of the absolute value or worthwhileness of such programs. This fundamental absolute value question should be asked of all non-profit programs and documented to the greatest possible extent in budgetary submissions, and subsequent control and audit. In public sector non-profit programs, the posing of this question requires information on consumer demand other than in aggregative and imprecise form through the political process, and much improved information on the cost side. Eliciting demand information is feasible in the case of public programs with separable benefits by the use of a variety of pricing techniques, direct or imputed, whether or not the service in question is ultimately financed on a user-pay basis. The problem of eliciting demand is more difficult in the case of public goods, but improved demand information can be obtained, ideally by an approach such as the use of a Clarke tax. The argument can be extended to encompass questions of income distribution, stabilization, regulation and tax policy. Recent developments in program evaluation in the federal government are important, but remain deficient in failing to address the question of absolute value.

  14. A signal-detection-based diagnostic-feature-detection model of eyewitness identification.

    PubMed

    Wixted, John T; Mickes, Laura

    2014-04-01

    The theoretical understanding of eyewitness identifications made from a police lineup has long been guided by the distinction between absolute and relative decision strategies. In addition, the accuracy of identifications associated with different eyewitness memory procedures has long been evaluated using measures like the diagnosticity ratio (the correct identification rate divided by the false identification rate). Framed in terms of signal-detection theory, both the absolute/relative distinction and the diagnosticity ratio are mainly relevant to response bias while remaining silent about the key issue of diagnostic accuracy, or discriminability (i.e., the ability to tell the difference between innocent and guilty suspects in a lineup). Here, we propose a signal-detection-based model of eyewitness identification, one that encourages the use of (and helps to conceptualize) receiver operating characteristic (ROC) analysis to measure discriminability. Recent ROC analyses indicate that the simultaneous presentation of faces in a lineup yields higher discriminability than the presentation of faces in isolation, and we propose a diagnostic feature-detection hypothesis to account for that result. According to this hypothesis, the simultaneous presentation of faces allows the eyewitness to appreciate that certain facial features (viz., those that are shared by everyone in the lineup) are non-diagnostic of guilt. To the extent that those non-diagnostic features are discounted in favor of potentially more diagnostic features, the ability to discriminate innocent from guilty suspects will be enhanced.

  15. Absolute cross-sections for DNA strand breaks and crosslinks induced by low energy electrons

    PubMed Central

    Chen, Wenzhuang; Chen, Shiliang; Dong, Yanfang; Cloutier, Pierre; Sanche, Léon

    2016-01-01

    Absolute cross sections (CSs) for the interaction of low energy electrons with condensed macromolecules are essential parameters to accurately model ionizing radiation induced reactions. To determine CSs for various conformational DNA damage induced by 2–20 eV electrons, we investigated the influence of the attenuation length (AL) and penetration factor (f) using a mathematical model. Solid films of super-coiled plasmid DNA with thicknesses of 10, 15 and 20 nm were irradiated with 4.6, 5.6, 9.6 and 14.6 eV electrons. DNA conformational changes were quantified by gel electrophoresis, and the respective yields were extrapolated from exposure–response curves. The absolute CS, AL and f values were generated by applying the model developed by Rezaee et al. The values of AL were found to lie between 11 and 16 nm with the maximum at 14.6 eV. The absolute CSs for the loss of the supercoiled (LS) configuration and production of crosslinks (CL), single strand breaks (SSB) and double strand breaks (DSB) induced by 4.6, 5.6, 9.6 and 14.6 eV electrons are obtained. The CSs for SSB are smaller, but similar to those for LS, indicating that SSB are the main conformational damage. The CSs for DSB and CL are about one order of magnitude smaller than those of LS and SSB. The value of f is found to be independent of electron energy, which allows extending the absolute CSs for these types of damage within the range 2–20 eV, from previous measurements of effective CSs. When comparison is possible, the absolute CSs are found to be in good agreement with those obtained from previous similar studies with double-stranded DNA. The high values of the absolute CSs of 4.6 and 9.6 eV provide quantitative evidence for the high efficiency of low energy electrons to induce DNA damage via the formation of transient anions. PMID:27878170

  16. Absolute cross-sections for DNA strand breaks and crosslinks induced by low energy electrons.

    PubMed

    Chen, Wenzhuang; Chen, Shiliang; Dong, Yanfang; Cloutier, Pierre; Zheng, Yi; Sanche, Léon

    2016-12-07

    Absolute cross sections (CSs) for the interaction of low energy electrons with condensed macromolecules are essential parameters to accurately model ionizing radiation induced reactions. To determine CSs for various conformational DNA damage induced by 2-20 eV electrons, we investigated the influence of the attenuation length (AL) and penetration factor (f) using a mathematical model. Solid films of supercoiled plasmid DNA with thicknesses of 10, 15 and 20 nm were irradiated with 4.6, 5.6, 9.6 and 14.6 eV electrons. DNA conformational changes were quantified by gel electrophoresis, and the respective yields were extrapolated from exposure-response curves. The absolute CS, AL and f values were generated by applying the model developed by Rezaee et al. The values of AL were found to lie between 11 and 16 nm with the maximum at 14.6 eV. The absolute CSs for the loss of the supercoiled (LS) configuration and production of crosslinks (CL), single strand breaks (SSB) and double strand breaks (DSB) induced by 4.6, 5.6, 9.6 and 14.6 eV electrons are obtained. The CSs for SSB are smaller, but similar to those for LS, indicating that SSB are the main conformational damage. The CSs for DSB and CL are about one order of magnitude smaller than those of LS and SSB. The value of f is found to be independent of electron energy, which allows extending the absolute CSs for these types of damage within the range 2-20 eV, from previous measurements of effective CSs. When comparison is possible, the absolute CSs are found to be in good agreement with those obtained from previous similar studies with double-stranded DNA. The high values of the absolute CSs of 4.6 and 9.6 eV provide quantitative evidence for the high efficiency of low energy electrons to induce DNA damage via the formation of transient anions.

  17. Effect of Ozone Addition on Combustion Efficiency of Hydrogen: Liquid-Oxygen Propellant in Small Rockets

    NASA Technical Reports Server (NTRS)

    Miller, Riley O.; Brown, Dwight D.

    1959-01-01

    An experimental study shows that 2 percent by weight ozone in oxygen has little effect on overall reactivity for a range of oxidant-fuel weight ratios from 1 to 6. This conclusion is based on characteristic-velocity measurements in 200-pound-thrust chambers at a pressure of 300 pounds per square inch absolute with low-efficiency injectors. The presence of 9 percent ozone in oxygen also did not affect performance in an efficient chamber. Explosions were encountered when equipment or procedure permitted ozone to concentrate locally. These experiments indicate that even small amounts of ozone in oxygen can cause operational problems.

  18. Microwave Detection of Chemical Agents: A Review

    DTIC Science & Technology

    1986-06-01

    Health (NIOSH).8’l1 This instrument was designed to detect acetonitrile, acetaldehyde , acetone, carbonyl sulfide, ethanol, ethylene oxide , isopropyl...absolute temperature mij - the dipole matrix element connecting the upper and lower energy states vo = the absorption line center v - transition...from multiple reflections through the cell. The Q of a cavity is defined as the electro - magnetic energy in the cavity divided by the energy lost per

  19. Evaluation of the performance of quantitative detection of the Listeria monocytogenes prfA locus with droplet digital PCR.

    PubMed

    Witte, Anna Kristina; Fister, Susanne; Mester, Patrick; Schoder, Dagmar; Rossmanith, Peter

    2016-11-01

    Fast and reliable pathogen detection is an important issue for human health. Since conventional microbiological methods are rather slow, there is growing interest in detection and quantification using molecular methods. The droplet digital polymerase chain reaction (ddPCR) is a relatively new PCR method for absolute and accurate quantification without external standards. Using the Listeria monocytogenes specific prfA assay, we focused on the questions of whether the assay was directly transferable to ddPCR and whether ddPCR was suitable for samples derived from heterogeneous matrices, such as foodstuffs that often included inhibitors and a non-target bacterial background flora. Although the prfA assay showed suboptimal cluster formation, use of ddPCR for quantification of L. monocytogenes from pure bacterial cultures, artificially contaminated cheese, and naturally contaminated foodstuff was satisfactory over a relatively broad dynamic range. Moreover, results demonstrated the outstanding detection limit of one copy. However, while poorer DNA quality, such as resulting from longer storage, can impair ddPCR, internal amplification control (IAC) of prfA by ddPCR, that is integrated in the genome of L. monocytogenes ΔprfA, showed even slightly better quantification over a broader dynamic range. Graphical Abstract Evaluating the absolute quantification potential of ddPCR targeting Listeria monocytogenes prfA.

  20. Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.; Volden, T.

    2014-01-01

    An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

  1. 40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... provide output of relative or absolute particulate matter loadings. (5) The bag leak detection system must..., repairs, calibration checks, and zero and span adjustments, emissions data must be obtained by using other...

  2. Near-Inertial and Tidal Currents Detected with a Vessel Mounted Acoustic Doppler Current Profiler in the Western Mediterranean Sea

    NASA Technical Reports Server (NTRS)

    Garcia-Gorriz, E.; Candela, J.; Font, J.

    1998-01-01

    The Acoustic Doppler Current Profiler (ADCP) combined with accurate navigation provides absolute current velocities which include information from all the frequencies which have a dynamical presence in the ocean.

  3. Optical Characterization of Tissue Phantoms Using a Silicon Integrated fdNIRS System on Chip.

    PubMed

    Sthalekar, Chirag C; Miao, Yun; Koomson, Valencia Joyner

    2017-04-01

    An interface circuit with signal processing and digitizing circuits for a high frequency, large area avalanche photodiode (APD) has been integrated in a 130 nm BiCMOS chip. The system enables the absolute oximetry of tissue using frequency domain Near Infrared Spectroscopy (fdNIRS). The system measures the light absorbed and scattered by the tissue by measuring the reduction in the amplitude of signal and phase shift introduced between the light source and detector which are placed a finite distance away from each other. The received 80 MHz RF signal is downconverted to a low frequency and amplified using a heterodyning scheme. The front-end transimpedance amplifier has a 3-level programmable gain that increases the dynamic range to 60 dB. The phase difference between an identical reference channel and the optical channel is measured with a 0.5° accuracy. The detectable current range is [Formula: see text] and with a 40 A/W reponsivity using the APD, power levels as low as 500 pW can be detected. Measurements of the absorption and reduced scattering coefficients of solid tissue phantoms using this system are compared with those using a commercial instrument with differences within 30%. Measurement of a milk based liquid tissue phantom show an increase in absorption coefficient with addition of black ink. The miniaturized circuit serves as an efficiently scalable system for multi-site detection for applications in neonatal cerebral oximetry and optical mammography.

  4. An efficient and ultrasensitive rhodamine B-based reversible colorimetric chemosensor for naked-eye recognition of molybdenum and citrate ions in aqueous solution: Sensing behavior and logic operation

    NASA Astrophysics Data System (ADS)

    Tavallali, Hossein; Deilamy-Rad, Gohar; Parhami, Abolfath; Hasanli, Nahid

    2015-03-01

    In this paper we manifest a novel rhodamine B (RhB) based colorimetric chemosensor for molybdenum and citrate ions (Cit3-) in an absolutely aqueous media. It has been identified as highly sensitive probe for Mo6+ which responds at 4.0 nmol L-1 concentration levels. RhB while combined with Mo6+ in aqueous solution displays a color changing from pink to purple which could be quickly dissociated by the addition of citrate in this system so that reversible color changes from purple to pink can be achieved. The comparison of this method with some other methods for citrate indicates that this is the only method which can detect citrate in aqueous solution by color changes. This chemosensor can be applied for quantification of citrate with a linear range covering from 1.67 × 10-7 to 1.22 × 10-5 M and a detection limit of 2.0 × 10-8 M. Moreover, the response of the chemosensor toward Mo6+ and citrate is fast. In addition, based on above sensing mechanism, an IMPLICATION logic operation can be achieved using Mo6+ ion and Cit3- as the inputs, making RhB a promising candidate for further applications in molecular logic devices and also indicates that RhB is suitable for the detection of Mo6+ and Cit3- ions in real samples.

  5. An efficient and ultrasensitive rhodamine B-based reversible colorimetric chemosensor for naked-eye recognition of molybdenum and citrate ions in aqueous solution: sensing behavior and logic operation.

    PubMed

    Tavallali, Hossein; Deilamy-Rad, Gohar; Parhami, Abolfath; Hasanli, Nahid

    2015-03-15

    In this paper we manifest a novel rhodamine B (RhB) based colorimetric chemosensor for molybdenum and citrate ions (Cit(3-)) in an absolutely aqueous media. It has been identified as highly sensitive probe for Mo(6+) which responds at 4.0 nmol L(-1) concentration levels. RhB while combined with Mo(6+) in aqueous solution displays a color changing from pink to purple which could be quickly dissociated by the addition of citrate in this system so that reversible color changes from purple to pink can be achieved. The comparison of this method with some other methods for citrate indicates that this is the only method which can detect citrate in aqueous solution by color changes. This chemosensor can be applied for quantification of citrate with a linear range covering from 1.67×10(-7) to 1.22×10(-5) M and a detection limit of 2.0×10(-8) M. Moreover, the response of the chemosensor toward Mo(6+) and citrate is fast. In addition, based on above sensing mechanism, an IMPLICATION logic operation can be achieved using Mo(6+) ion and Cit(3-) as the inputs, making RhB a promising candidate for further applications in molecular logic devices and also indicates that RhB is suitable for the detection of Mo(6+) and Cit(3-) ions in real samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Tin speciation in the femtogram range in open ocean seawater by gas chromatography/inductively coupled plasma mass spectrometry using a shield torch at normal plasma conditions.

    PubMed

    Tao, H; Rajendran, R B; Quetel, C R; Nakazato, T; Tominaga, M; Miyazaki, A

    1999-10-01

    A sensitive method for the determination of ultratrace organotin species in seawater is described. The merits and demerits of derivatization methods using Grignard reagent or sodium tetraethylborate (NaBEt4) were evaluated in terms of derivatization efficiency, applicability to the programmed temperature vaporization (PTV) method, and procedural blanks. The sensitivity of the gas chromatography/inductively coupled plasma mass spectrometry (GC/ICPMS) was improved by more than 100-fold by operating the shield torch at normal plasma conditions, compared with that obtained without using it. The absolute detection limit as tin reached subfemtogram (fg) levels. Furthermore, the detection limit in terms of relative concentration was improved 100-fold by using the PTV method, which enabled the injection of a large sample volume of as much as 100 microL without loss of analyte. When the organotin species in seawater were extracted into hexane with a preconcentration factor of 1000 after ethylation with NaBEt4 and a 100 microL aliquot of the extract was injected into the GC, the instrumental detection limit in relative concentration reached 0.01 pg/L in original seawater. Sources of contamination of organotin species during the sample preparation were examined, and a purification method of NaBEt4 was developed. Finally, the method was successfully applied to open ocean seawater samples containing organotin species at the level of 1-100 pg/L.

  7. Measuring temporal summation in visual detection with a single-photon source.

    PubMed

    Holmes, Rebecca; Victora, Michelle; Wang, Ranxiao Frances; Kwiat, Paul G

    2017-11-01

    Temporal summation is an important feature of the visual system which combines visual signals that arrive at different times. Previous research estimated complete summation to last for 100ms for stimuli judged "just detectable." We measured the full range of temporal summation for much weaker stimuli using a new paradigm and a novel light source, developed in the field of quantum optics for generating small numbers of photons with precise timing characteristics and reduced variance in photon number. Dark-adapted participants judged whether a light was presented to the left or right of their fixation in each trial. In Experiment 1, stimuli contained a stream of photons delivered at a constant rate while the duration was systematically varied. Accuracy should increase with duration as long as the later photons can be integrated with the proceeding ones into a single signal. The temporal integration window was estimated as the point that performance no longer improved, and was found to be 650ms on average. In Experiment 2, the duration of the visual stimuli was kept short (100ms or <30ms) while the number of photons was varied to explore the efficiency of summation over the integration window compared to Experiment 1. There was some indication that temporal summation remains efficient over the integration window, although there is variation between individuals. The relatively long integration window measured in this study may be relevant to studies of the absolute visual threshold, i.e., tests of single-photon vision, where "single" photons should be separated by greater than the integration window to avoid summation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. A novel EPID design for enhanced contrast and detective quantum efficiency

    NASA Astrophysics Data System (ADS)

    Rottmann, Joerg; Morf, Daniel; Fueglistaller, Rony; Zentai, George; Star-Lack, Josh; Berbeco, Ross

    2016-09-01

    Beams-eye-view imaging applications such as real-time soft-tissue motion estimation are hindered by the inherently low image contrast of electronic portal imaging devices (EPID) currently available for clinical use. We introduce and characterize a novel EPID design that provides substantially increased detective quantum efficiency (DQE), contrast-to-noise ratio (CNR) and sensitivity without degradation in spatial resolution. The prototype design features a stack of four conventional EPID layers combined with low noise integrated readout electronics. Each layer consists of a copper plate, a scintillator (\\text{G}{{\\text{d}}2}{{\\text{O}}2}{{\\text{S}}{}}\\text{:Tb} ) and a photodiode/TFT-switch (aSi:H). We characterize the prototype’s signal response to a 6 MV photon beam in terms of modulation transfer function (MTF), DQE and CNR. The presampled MTF is estimated using a slanted slit technique, the DQE is calculated from measured normalized noise power spectra (nNPS) and the MTF and CNR is estimated using a Las Vegas contrast phantom. The prototype has been designed and built to be interchangeable with the current clinical EPID on the Varian TrueBeam platform (AS-1200) in terms of size and data output specifications. Performance evaluation is conducted in absolute values as well as in relative terms using the Varian AS-1200 EPID as a reference detector. A fivefold increase of DQE(0) to about 6.7% was observed by using the four-layered design versus the AS-1200 reference detector. No substantial differences are observed between each layer’s individual MTF and the one for all four layers operating combined indicating that defocusing due to beam divergence is negligible. Also, using four layers instead of one increases the signal to noise ratio by a factor of 1.7.

  9. Multivariate regression methods for estimating velocity of ictal discharges from human microelectrode recordings

    NASA Astrophysics Data System (ADS)

    Liou, Jyun-you; Smith, Elliot H.; Bateman, Lisa M.; McKhann, Guy M., II; Goodman, Robert R.; Greger, Bradley; Davis, Tyler S.; Kellis, Spencer S.; House, Paul A.; Schevon, Catherine A.

    2017-08-01

    Objective. Epileptiform discharges, an electrophysiological hallmark of seizures, can propagate across cortical tissue in a manner similar to traveling waves. Recent work has focused attention on the origination and propagation patterns of these discharges, yielding important clues to their source location and mechanism of travel. However, systematic studies of methods for measuring propagation are lacking. Approach. We analyzed epileptiform discharges in microelectrode array recordings of human seizures. The array records multiunit activity and local field potentials at 400 micron spatial resolution, from a small cortical site free of obstructions. We evaluated several computationally efficient statistical methods for calculating traveling wave velocity, benchmarking them to analyses of associated neuronal burst firing. Main results. Over 90% of discharges met statistical criteria for propagation across the sampled cortical territory. Detection rate, direction and speed estimates derived from a multiunit estimator were compared to four field potential-based estimators: negative peak, maximum descent, high gamma power, and cross-correlation. Interestingly, the methods that were computationally simplest and most efficient (negative peak and maximal descent) offer non-inferior results in predicting neuronal traveling wave velocities compared to the other two, more complex methods. Moreover, the negative peak and maximal descent methods proved to be more robust against reduced spatial sampling challenges. Using least absolute deviation in place of least squares error minimized the impact of outliers, and reduced the discrepancies between local field potential-based and multiunit estimators. Significance. Our findings suggest that ictal epileptiform discharges typically take the form of exceptionally strong, rapidly traveling waves, with propagation detectable across millimeter distances. The sequential activation of neurons in space can be inferred from clinically-observable EEG data, with a variety of straightforward computation methods available. This opens possibilities for systematic assessments of ictal discharge propagation in clinical and research settings.

  10. On the robustness of EC-PC spike detection method for online neural recording.

    PubMed

    Zhou, Yin; Wu, Tong; Rastegarnia, Amir; Guan, Cuntai; Keefer, Edward; Yang, Zhi

    2014-09-30

    Online spike detection is an important step to compress neural data and perform real-time neural information decoding. An unsupervised, automatic, yet robust signal processing is strongly desired, thus it can support a wide range of applications. We have developed a novel spike detection algorithm called "exponential component-polynomial component" (EC-PC) spike detection. We firstly evaluate the robustness of the EC-PC spike detector under different firing rates and SNRs. Secondly, we show that the detection Precision can be quantitatively derived without requiring additional user input parameters. We have realized the algorithm (including training) into a 0.13 μm CMOS chip, where an unsupervised, nonparametric operation has been demonstrated. Both simulated data and real data are used to evaluate the method under different firing rates (FRs), SNRs. The results show that the EC-PC spike detector is the most robust in comparison with some popular detectors. Moreover, the EC-PC detector can track changes in the background noise due to the ability to re-estimate the neural data distribution. Both real and synthesized data have been used for testing the proposed algorithm in comparison with other methods, including the absolute thresholding detector (AT), median absolute deviation detector (MAD), nonlinear energy operator detector (NEO), and continuous wavelet detector (CWD). Comparative testing results reveals that the EP-PC detection algorithm performs better than the other algorithms regardless of recording conditions. The EC-PC spike detector can be considered as an unsupervised and robust online spike detection. It is also suitable for hardware implementation. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Multiplex enrichment quantitative PCR (ME-qPCR): a high-throughput, highly sensitive detection method for GMO identification.

    PubMed

    Fu, Wei; Zhu, Pengyu; Wei, Shuang; Zhixin, Du; Wang, Chenguang; Wu, Xiyang; Li, Feiwu; Zhu, Shuifang

    2017-04-01

    Among all of the high-throughput detection methods, PCR-based methodologies are regarded as the most cost-efficient and feasible methodologies compared with the next-generation sequencing or ChIP-based methods. However, the PCR-based methods can only achieve multiplex detection up to 15-plex due to limitations imposed by the multiplex primer interactions. The detection throughput cannot meet the demands of high-throughput detection, such as SNP or gene expression analysis. Therefore, in our study, we have developed a new high-throughput PCR-based detection method, multiplex enrichment quantitative PCR (ME-qPCR), which is a combination of qPCR and nested PCR. The GMO content detection results in our study showed that ME-qPCR could achieve high-throughput detection up to 26-plex. Compared to the original qPCR, the Ct values of ME-qPCR were lower for the same group, which showed that ME-qPCR sensitivity is higher than the original qPCR. The absolute limit of detection for ME-qPCR could achieve levels as low as a single copy of the plant genome. Moreover, the specificity results showed that no cross-amplification occurred for irrelevant GMO events. After evaluation of all of the parameters, a practical evaluation was performed with different foods. The more stable amplification results, compared to qPCR, showed that ME-qPCR was suitable for GMO detection in foods. In conclusion, ME-qPCR achieved sensitive, high-throughput GMO detection in complex substrates, such as crops or food samples. In the future, ME-qPCR-based GMO content identification may positively impact SNP analysis or multiplex gene expression of food or agricultural samples. Graphical abstract For the first-step amplification, four primers (A, B, C, and D) have been added into the reaction volume. In this manner, four kinds of amplicons have been generated. All of these four amplicons could be regarded as the target of second-step PCR. For the second-step amplification, three parallels have been taken for the final evaluation. After the second evaluation, the final amplification curves and melting curves have been achieved.

  12. ESTIMATION OF RADIOACTIVE CALCIUM-45 BY LIQUID SCINTILLATION COUNTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lutwak, L.

    1959-03-01

    A liquid sclntillation counting method is developed for determining radioactive calcium-45 in biological materials. The calcium-45 is extracted, concentrated, and dissolved in absolute ethyl alcohol to which is added 0.4% diphenyloxazol in toluene. Counting efficiency is about 65 percent with standard deviation of the J-57 engin 7.36 percent. (auth)

  13. Comparison of droplet digital PCR with quantitative real-time PCR for determination of zygosity in transgenic maize.

    PubMed

    Xu, Xiaoli; Peng, Cheng; Wang, Xiaofu; Chen, Xiaoyun; Wang, Qiang; Xu, Junfeng

    2016-12-01

    This study evaluated the applicability of droplet digital PCR (ddPCR) as a tool for maize zygosity determination using quantitative real-time PCR (qPCR) as a reference technology. Quantitative real-time PCR is commonly used to determine transgene copy number or GMO zygosity characterization. However, its effectiveness is based on identical reaction efficiencies for the transgene and the endogenous reference gene. Additionally, a calibrator sample should be utilized for accuracy. Droplet digital PCR is a DNA molecule counting technique that directly counts the absolute number of target and reference DNA molecules in a sample, independent of assay efficiency or external calibrators. The zygosity of the transgene can be easily determined using the ratio of the quantity of the target gene to the reference single copy endogenous gene. In this study, both the qPCR and ddPCR methods were used to determine insect-resistant transgenic maize IE034 zygosity. Both methods performed well, but the ddPCR method was more convenient because of its absolute quantification property.

  14. Heterodyne efficiency for a coherent laser radar with diffuse or aerosol targets

    NASA Technical Reports Server (NTRS)

    Frehlich, R. G.

    1993-01-01

    The performance of a Coherent Laser Radar is determined by the statistics of the coherent Doppler signal. The heterodyne efficiency is an excellent indication of performance because it is an absolute measure of beam alignment and is independent of the transmitter power, the target backscatter coefficient, the atmospheric attenuation, and the detector quantum efficiency and gain. The theoretical calculation of heterodyne efficiency for an optimal monostatic lidar with a circular aperture and Gaussian transmit laser is presented including beam misalignment in the far-field and near-field regimes. The statistical behavior of estimates of the heterodyne efficiency using a calibration hard target are considered. For space based applications, a biased estimate of heterodyne efficiency is proposed that removes the variability due to the random surface return but retains the sensitivity to misalignment. Physical insight is provided by simulation of the fields on the detector surface. The required detector calibration is also discussed.

  15. Multigrid Computations of 3-D Incompressible Internal and External Viscous Rotating Flows

    NASA Technical Reports Server (NTRS)

    Sheng, Chunhua; Taylor, Lafayette K.; Chen, Jen-Ping; Jiang, Min-Yee; Whitfield, David L.

    1996-01-01

    This report presents multigrid methods for solving the 3-D incompressible viscous rotating flows in a NASA low-speed centrifugal compressor and a marine propeller 4119. Numerical formulations are given in both the rotating reference frame and the absolute frame. Comparisons are made for the accuracy, efficiency, and robustness between the steady-state scheme and the time-accurate scheme for simulating viscous rotating flows for complex internal and external flow applications. Prospects for further increase in efficiency and accuracy of unsteady time-accurate computations are discussed.

  16. Optical properties of thin gold films applied to Schottky barrier solar cells

    NASA Technical Reports Server (NTRS)

    YEH Y. M.

    1974-01-01

    The Schottky barrier solar cell is considered a possible candidate for converting solar to electrical energy both for space and terrestrial applications. Knowledge of the optical constants of the ultrathin metal film used in the cell is essential for analyzing and designing higher efficiency Schottky barrier cells. The optical constants of 7.5 -nm (75-A) gold films on gallium arsenide have been obtained. In addition, the absolute collection efficiency of Schottky barrier solar cells has been determined from measured spectral response and optical constants of the gold film.

  17. Efficiency at maximum power for an isothermal chemical engine with particle exchange at varying chemical potential

    NASA Astrophysics Data System (ADS)

    Koning, Jesper; Koga, Kenichiro; Indekeu, Joseph. O.

    2017-02-01

    We calculate the efficiency at maximum power (EMP) of an isothermal chemical cycle in which particle uptake occurs at a fixed chemical potential but particle release takes place at varying chemical potential. We obtain the EMP as a function of Δμ/ kT, where Δμ is the difference between the highest and lowest reservoir chemical potentials and T is the absolute temperature. In the linear response limit, Δμ ≪ kT, the EMP tends to the expected universal value 1/2.

  18. Exergetic analysis of autonomous power complex for drilling rig

    NASA Astrophysics Data System (ADS)

    Lebedev, V. A.; Karabuta, V. S.

    2017-10-01

    The article considers the issue of increasing the energy efficiency of power equipment of the drilling rig. At present diverse types of power plants are used in power supply systems. When designing and choosing a power plant, one of the main criteria is its energy efficiency. The main indicator in this case is the effective efficiency factor calculated by the method of thermal balances. In the article, it is suggested to use the exergy method to determine energy efficiency, which allows to perform estimations of the thermodynamic perfection degree of the system by the example of a gas turbine plant: relative estimation (exergetic efficiency factor) and an absolute estimation. An exergetic analysis of the gas turbine plant operating in a simple scheme was carried out using the program WaterSteamPro. Exergy losses in equipment elements are calculated.

  19. High Efficiency Carbon Nanotube Thread Antennas

    NASA Astrophysics Data System (ADS)

    Bengio, Elie; Senic, Damir; Taylor, Lauren; Tsentalovich, Dmitri; Chen, Peiyu; Holloway, Christopher; Novotny, David; Babakhani, Aydin; Long, Christopher; Booth, James; Orloff, Nathan; Pasquali, Matteo

    Although previous research has explored the underlying theory of high-frequency behavior of carbon nanotubes (CNTs) and CNT bundles for antennas, there is a gap in the literature for direct experimental measurements of radiation efficiency. Here we report a novel measurement technique to accurately characterize the radiation efficiency of quarter-wavelength monopole antennas made from CNT thread. At medical device (1 GHz) and Wi-Fi (2.4 GHz) frequencies, we measured the highest absolute values of radiation efficiency in the literature for CNT antennas, matching that of copper wire. We also report the first direct experimental observation that, contrary to metals, the radiation efficiency of the CNT thread improves significantly at higher frequencies. These results pave the way for practical applications of CNT thread antennas, particularly in the aerospace and wearable electronics industries where weight saving is a priority.

  20. Measurement of the Neutron Lifetime Using a Proton Trap

    NASA Astrophysics Data System (ADS)

    Dewey, M. S.; Gilliam, D. M.; Nico, J. S.; Wietfeldt, F. E.; Fei, X.; Snow, W. M.; Greene, G. L.; Pauwels, J.; Eykens, R.; Lamberty, A.; van Gestel, J.

    2003-10-01

    We report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neu­tron lifetime: τn=(886.8±1.2[stat]±3.2[syst]) s. The systematic uncertainty is dominated by uncertainties in the mass of the 6LiF deposit and the 6Li(n,t) cross section. This is the most precise measurement of the neutron lifetime to date using an in-beam method.

  1. Absolute intensities and self-, N2-, and air-broadened Lorentz halfwidths for selected lines in the nu3 band of (C-12)H3D from measurements with a tunable diode laser spectrometer

    NASA Technical Reports Server (NTRS)

    Malathy Devi, V.; Benner, D. C.; Rinsland, C. P.; Smith, M. A. H.; Thakur, K. B.

    1986-01-01

    Absolute intensities and self-, air- and N2-broadened half-widths have been determined for the first time for individual lines in the nu3(A1) band of (C-12)H3D near 7.6 microns from measurements of individual vibration-rotation lines using a tunable diode laser spectrometer. The intensity measurements are believed to be accurate to within three percent. Within experimental uncertainties, equal broadening efficiencies are found for both air and nitrogen. Self-broadened half-widths determined for three transitions yield an average half-width value of 0.803 + or -0.0010/cm/atm at 296 K.

  2. Is There a Clinical Role For Smartphone Sleep Apps? Comparison of Sleep Cycle Detection by a Smartphone Application to Polysomnography

    PubMed Central

    Bhat, Sushanth; Ferraris, Ambra; Gupta, Divya; Mozafarian, Mona; DeBari, Vincent A.; Gushway-Henry, Neola; Gowda, Satish P.; Polos, Peter G.; Rubinstein, Mitchell; Seidu, Huzaifa; Chokroverty, Sudhansu

    2015-01-01

    Study Objectives: Several inexpensive, readily available smartphone apps that claim to monitor sleep are popular among patients. However, their accuracy is unknown, which limits their widespread clinical use. We therefore conducted this study to evaluate the validity of parameters reported by one such app, the Sleep Time app (Azumio, Inc., Palo Alto, CA, USA) for iPhones. Methods: Twenty volunteers with no previously diagnosed sleep disorders underwent in-laboratory polysomnography (PSG) while simultaneously using the app. Parameters reported by the app were then compared to those obtained by PSG. In addition, an epoch-by-epoch analysis was performed by dividing the PSG and app graph into 15-min epochs. Results: There was no correlation between PSG and app sleep efficiency (r = −0.127, p = 0.592), light sleep percentage (r = 0.024, p = 0.921), deep sleep percentage (r = 0.181, p = 0.444) or sleep latency (rs = 0.384, p = 0.094). The app slightly and nonsignificantly overestimated sleep efficiency by 0.12% (95% confidence interval [CI] −4.9 to 5.1%, p = 0.962), significantly underestimated light sleep by 27.9% (95% CI 19.4–36.4%, p < 0.0001), significantly overestimated deep sleep by 11.1% (CI 4.7–17.4%, p = 0.008) and significantly overestimated sleep latency by 15.6 min (CI 9.7–21.6, p < 0.0001). Epochwise comparison showed low overall accuracy (45.9%) due to poor interstage discrimination, but high accuracy in sleep-wake detection (85.9%). The app had high sensitivity but poor specificity in detecting sleep (89.9% and 50%, respectively). Conclusions: Our study shows that the absolute parameters and sleep staging reported by the Sleep Time app (Azumio, Inc.) for iPhones correlate poorly with PSG. Further studies comparing app sleep-wake detection to actigraphy may help elucidate its potential clinical utility. Commentary: A commentary on this article appears in this issue on page 695. Citation: Bhat S, Ferraris A, Gupta D, Mozafarian M, DeBari VA, Gushway-Henry N, Gowda SP, Polos PG, Rubinstein M, Seidu H, Chokroverty S. Is there a clinical role for smartphone sleep apps? Comparison of sleep cycle detection by a smartphone application to polysomnography. J Clin Sleep Med 2015;11(7):709–715. PMID:25766719

  3. Detecting Topological Defect Dark Matter Using Coherent Laser Ranging System

    PubMed Central

    Yang, Wanpeng; Leng, Jianxiao; Zhang, Shuangyou; Zhao, Jianye

    2016-01-01

    In the last few decades, optical frequency combs with high intensity, broad optical bandwidth, and directly traceable discrete wavelengths have triggered rapid developments in distance metrology. However, optical frequency combs to date have been limited to determine the absolute distance to an object (such as satellite missions). We propose a scheme for the detection of topological defect dark matter using a coherent laser ranging system composed of dual-combs and an optical clock via nongravitational signatures. The dark matter field, which comprises a defect, may interact with standard model particles, including quarks and photons, resulting in the alteration of their masses. Thus, a topological defect may function as a dielectric material with a distinctive frequency-depend index of refraction, which would cause the time delay of a periodic extraterrestrial or terrestrial light. When a topological defect passes through the Earth, the optical path of long-distance vacuum path is altered, this change in optical path can be detected through the coherent laser ranging system. Compared to continuous wavelength(cw) laser interferometry methods, dual-comb interferometry in our scheme excludes systematic misjudgement by measuring the absolute optical path length. PMID:27389642

  4. Teaching Point-of-Care Lung Ultrasound to Novice Pediatric Learners: Web-Based E-Learning Versus Traditional Classroom Didactic.

    PubMed

    Soon, Aun Woon; Toney, Amanda Greene; Stidham, Timothy; Kendall, John; Roosevelt, Genie

    2018-04-24

    To assess whether Web-based teaching is at least as effective as traditional classroom didactic in improving the proficiency of pediatric novice learners in the image acquisition and interpretation of pneumothorax and pleural effusion using point-of-care ultrasound (POCUS). We conducted a randomized controlled noninferiority study comparing the effectiveness of Web-based teaching to traditional classroom didactic. The participants were randomized to either group A (live classroom lecture) or group B (Web-based lecture) and completed a survey and knowledge test. They also received hands-on training and completed an objective structured clinical examination. The participants were invited to return 2 months later to test for retention of knowledge and skills. There were no significant differences in the mean written test scores between the classroom group and Web group for the precourse test (absolute difference, -2.5; 95% confidence interval [CI], -12 to 6.9), postcourse test (absolute difference, 2.0; 95% CI, -1.4, 5.3), and postcourse 2-month retention test (absolute difference, -0.8; 95% CI, -9.6 to 8.1). Similarly, no significant differences were noted in the mean objective structured clinical examination scores for both intervention groups in postcourse (absolute difference, 1.9; 95% CI, -4.7 to 8.5) and 2-month retention (absolute difference, -0.6; 95% CI, -10.7 to 9.5). Web-based teaching is at least as effective as traditional classroom didactic in improving the proficiency of novice learners in POCUS. The usage of Web-based tutorials allows a more efficient use of time and a wider dissemination of knowledge.

  5. 40 CFR 60.4880 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... section are met. (A) The zero (low-level), mid-level (if applicable), or high-level calibration drift... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  6. 40 CFR 60.4880 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... section are met. (A) The zero (low-level), mid-level (if applicable), or high-level calibration drift... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  7. 40 CFR 60.4880 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... section are met. (A) The zero (low-level), mid-level (if applicable), or high-level calibration drift... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  8. Determining the linkage of disease-resistance genes to molecular markers: the LOD-SCORE method revisited with regard to necessary sample sizes.

    PubMed

    Hühn, M

    1995-05-01

    Some approaches to molecular marker-assisted linkage detection for a dominant disease-resistance trait based on a segregating F2 population are discussed. Analysis of two-point linkage is carried out by the traditional measure of maximum lod score. It depends on (1) the maximum-likelihood estimate of the recombination fraction between the marker and the disease-resistance gene locus, (2) the observed absolute frequencies, and (3) the unknown number of tested individuals. If one replaces the absolute frequencies by expressions depending on the unknown sample size and the maximum-likelihood estimate of recombination value, the conventional rule for significant linkage (maximum lod score exceeds a given linkage threshold) can be resolved for the sample size. For each sub-population used for linkage analysis [susceptible (= recessive) individuals, resistant (= dominant) individuals, complete F2] this approach gives a lower bound for the necessary number of individuals required for the detection of significant two-point linkage by the lod-score method.

  9. Frequency characteristics of the heart rate variability produced by Cheyne-Stokes respiration during 24-hr ambulatory electrocardiographic monitoring.

    PubMed

    Ichimaru, Y; Yanaga, T

    1989-06-01

    Spectral analysis of heart rates during 24-hr ambulatory electrocardiographic monitoring has been carried out to characterize the heart rate spectral components of Cheyne-Stokes respiration (CSR) by using fast Fourier transformation (FFT). Eight patients with congestive heart failure were selected for the study. FFT analyses have been performed for 614.4 sec. Out of the power spectrum, five parameters were extracted to characterize the CSR. The low peak frequencies in eight subjects were between 0.0179 Hz (56 sec) and 0.0081 Hz (123 sec). The algorithms used to detect CSR are the followings: (i) if the LFPA/ULFA ratios were above the absolute value of 1.0, and (ii) the LFPP/MLFP ratios were above the absolute values of 4.0, then the power spectrum is suggestive of CSR. We conclude that the automatic detection of CSR by heart rate spectral analysis during ambulatory ECG monitoring may afford a tool for the evaluation of the patients with congestive heart failure.

  10. An automated system to measure the quantum efficiency of CCDs for astronomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coles, R.; Chiang, J.; Cinabro, D.

    We describe a system to measure the Quantum Efficiency in the wavelength range of 300 nm to 1100 nm of 40 × 40 mm n-channel CCD sensors for the construction of the 3.2 gigapixel LSST focal plane. The technique uses a series of instrument to create a very uniform flux of photons of controllable intensity in the wavelength range of interest across the face the sensor. This allows the absolute Quantum Efficiency to be measured with an accuracy in the 1% range. Finally, this system will be part of a production facility at Brookhaven National Lab for the basic componentmore » of the LSST camera.« less

  11. An automated system to measure the quantum efficiency of CCDs for astronomy

    DOE PAGES

    Coles, R.; Chiang, J.; Cinabro, D.; ...

    2017-04-18

    We describe a system to measure the Quantum Efficiency in the wavelength range of 300 nm to 1100 nm of 40 × 40 mm n-channel CCD sensors for the construction of the 3.2 gigapixel LSST focal plane. The technique uses a series of instrument to create a very uniform flux of photons of controllable intensity in the wavelength range of interest across the face the sensor. This allows the absolute Quantum Efficiency to be measured with an accuracy in the 1% range. Finally, this system will be part of a production facility at Brookhaven National Lab for the basic componentmore » of the LSST camera.« less

  12. Extreme ultraviolet performance of a multilayer coated high density toroidal grating

    NASA Technical Reports Server (NTRS)

    Thomas, Roger J.; Keski-Kuha, Ritva A. M.; Neupert, Werner M.; Condor, Charles E.; Gum, Jeffrey S.

    1991-01-01

    The performance of a multilayer coated diffraction grating has been evaluated at EUV wavelengths both in terms of absolute efficiency and spectral resolution. The application of ten-layer Ir/Si multilayer coating to a 3600-lines/mm blazed toroidal replica grating produced a factor of 9 enhancement in peak efficiency near the design wavelength of about 30 nm in first order, without degrading its excellent quasistigmatic spectral resolution. The measured EUV efficiency peaked at 3.3 percent and was improved over the full spectral range between 25 and 35 nm compared with the premultilayer replica which had a standard gold coating. In addition, the grating's spectral resolution of greater than 5000 was maintained.

  13. Balanced detection for self-mixing interferometry.

    PubMed

    Li, Kun; Cavedo, Federico; Pesatori, Alessandro; Zhao, Changming; Norgia, Michele

    2017-01-15

    We propose a new detection scheme for self-mixing interferometry using two photodiodes for implementing a differential acquisition. The method is based on the phase opposition of the self-mixing signal measured between the two laser diode facet outputs. The subtraction of the two outputs implements a sort of balanced detection that improves the signal quality, and allows canceling of unwanted signals due to laser modulation and disturbances on laser supply and transimpedance amplifier. Experimental results demonstrate the benefits of differential acquisition in a system for both absolute distance and displacement-vibration measurement. This Letter provides guidance for the design of self-mixing interferometers using balanced detection.

  14. Satellite SAR geocoding with refined RPC model

    NASA Astrophysics Data System (ADS)

    Zhang, Lu; Balz, Timo; Liao, Mingsheng

    2012-04-01

    Recent studies have proved that the Rational Polynomial Camera (RPC) model is able to act as a reliable replacement of the rigorous Range-Doppler (RD) model for the geometric processing of satellite SAR datasets. But its capability in absolute geolocation of SAR images has not been evaluated quantitatively. Therefore, in this article the problems of error analysis and refinement of SAR RPC model are primarily investigated to improve the absolute accuracy of SAR geolocation. Range propagation delay and azimuth timing error are identified as two major error sources for SAR geolocation. An approach based on SAR image simulation and real-to-simulated image matching is developed to estimate and correct these two errors. Afterwards a refined RPC model can be built from the error-corrected RD model and then used in satellite SAR geocoding. Three experiments with different settings are designed and conducted to comprehensively evaluate the accuracies of SAR geolocation with both ordinary and refined RPC models. All the experimental results demonstrate that with RPC model refinement the absolute location accuracies of geocoded SAR images can be improved significantly, particularly in Easting direction. In another experiment the computation efficiencies of SAR geocoding with both RD and RPC models are compared quantitatively. The results show that by using the RPC model such efficiency can be remarkably improved by at least 16 times. In addition the problem of DEM data selection for SAR image simulation in RPC model refinement is studied by a comparative experiment. The results reveal that the best choice should be using the proper DEM datasets of spatial resolution comparable to that of the SAR images.

  15. Properties and evolution of near-Earth-object families created by tidal disruption at the Earth

    NASA Astrophysics Data System (ADS)

    Schunova, E.; Walsh, K.; Granvik, M.; Jedicke, R.; Wainscoat, R.; Haghighipour, N.

    2014-07-01

    We have calculated the coherence and detectable lifetimes of synthetic near-Earth object (NEO) families created by catastrophic disruption of a progenitor as it suffers a very close Earth approach. The closest or slowest approaches yield the most violent 'S-class' disruption events and create a 'string of pearls' configuration of the resulting fragments after their reaccummulation into gravitationally bound components [3]. We found that the average absolute magnitude (H) difference between the parent body and the largest fragment is Δ H ˜ 1.0. The average slope of the absolute magnitude (H) distribution, N(H)∝10^{(0.55±0.04) H}, for the fragments in the S-class families is steeper than the slope of the NEO population [2] in the same size range. The families remain coherent as statistically significant clusters of orbits within the NEO population for an average of barτ_c = (14.7±0.6)×10^3 years after disruption. The detectable lifetimes of tidally disrupted families are extremely short compared to the multi-Myr and -Gyr lifetimes of main belt families due to the chaotic dynamical environment in NEO space -- they are detectable with the techniques developed by [1] and [4] for an average duration (barτ_{det}) ranging from about 2,000 to about 12,000 years for progenitors in the absolute magnitude (H_p) range from 20 to 13 corresponding to diameters in the range from about 0.5 to 10 km respectively. The maximum absolute magnitude of a progenitor capable of producing an observable NEO family (i.e. detectable by our family finding technique) is H_{p,max} = 20 (about 350 m diameter). The short detectability lifetime explains why zero NEO families have been discovered to-date. Nonetheless, every tidal disruption event of a progenitor with diameter greater than 0.5 km is capable of producing several million fragments in the 1 m to 10 m diameter range that can contribute to temporary local density enhancements of small NEOs in Earth's vicinity. These objects may be suitable targets for asteroid retrieval missions due to their Earth-like orbits with corresponding low v_∞ which permits low-cost missions. The fragments from the tidal disruptions evolve into orbits that bring them into collision with terrestrial planets or the Sun or they may be ejected from the solar system on hyperbolic orbits due to deep planetary encounters. The end-state for the fragments from a tidal disruption at Earth have ˜5× the collision probability with Earth compared to the background NEO population.

  16. Evaluating humidity recovery efficiency of currently available heat and moisture exchangers: a respiratory system model study.

    PubMed

    Lucato, Jeanette Janaina Jaber; Adams, Alexander Bernard; Souza, Rogério; Torquato, Jamili Anbar; Carvalho, Carlos Roberto Ribeiro; Marini, John J

    2009-01-01

    To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute humidity of air retrieved from and returned to the ventilated patient is an important measurable outcome of the heat and moisture exchangers' humidifying performance. Eight different heat and moisture exchangers were studied using a respiratory system analog. The system included a heated chamber (acrylic glass, maintained at 37 degrees C), a preserved swine lung, a hygrometer, circuitry and a ventilator. Humidity and temperature levels were measured using eight distinct interposed heat and moisture exchangers given different tidal volumes, respiratory frequencies and flow-rate conditions. Recovery of absolute humidity (%RAH) was calculated for each setting. Increasing tidal volumes led to a reduction in %RAH for all heat and moisture exchangers while no significant effect was demonstrated in the context of varying respiratory rate or inspiratory flow. Our data indicate that heat and moisture exchangers are more efficient when used with low tidal volume ventilation. The roles of flow and respiratory rate were of lesser importance, suggesting that their adjustment has a less significant effect on the performance of heat and moisture exchangers.

  17. Stability analysis of nonlinear systems with slope restricted nonlinearities.

    PubMed

    Liu, Xian; Du, Jiajia; Gao, Qing

    2014-01-01

    The problem of absolute stability of Lur'e systems with sector and slope restricted nonlinearities is revisited. Novel time-domain and frequency-domain criteria are established by using the Lyapunov method and the well-known Kalman-Yakubovich-Popov (KYP) lemma. The criteria strengthen some existing results. Simulations are given to illustrate the efficiency of the results.

  18. Graphs to estimate an individualized risk of breast cancer.

    PubMed

    Benichou, J; Gail, M H; Mulvihill, J J

    1996-01-01

    Clinicians who counsel women about their risk for developing breast cancer need a rapid method to estimate individualized risk (absolute risk), as well as the confidence limits around that point. The Breast Cancer Detection Demonstration Project (BCDDP) model (sometimes called the Gail model) assumes no genetic model and simultaneously incorporates five risk factors, but involves cumbersome calculations and interpolations. This report provides graphs to estimate the absolute risk of breast cancer from the BCDDP model. The BCDDP recruited 280,000 women from 1973 to 1980 who were monitored for 5 years. From this cohort, 2,852 white women developed breast cancer and 3,146 controls were selected, all with complete risk-factor information. The BCDDP model, previously developed from these data, was used to prepare graphs that relate a specific summary relative-risk estimate to the absolute risk of developing breast cancer over intervals of 10, 20, and 30 years. Once a summary relative risk is calculated, the appropriate graph is chosen that shows the 10-, 20-, or 30-year absolute risk of developing breast cancer. A separate graph gives the 95% confidence limits around the point estimate of absolute risk. Once a clinician rules out a single gene trait that predisposes to breast cancer and elicits information on age and four risk factors, the tables and figures permit an estimation of a women's absolute risk of developing breast cancer in the next three decades. These results are intended to be applied to women who undergo regular screening. They should be used only in a formal counseling program to maximize a woman's understanding of the estimates and the proper use of them.

  19. Suitability of polydimethylsiloxane rods for the headspace sorptive extraction of polybrominated diphenyl ethers from water samples.

    PubMed

    Montes, R; Rodríguez, I; Rubí, E; Cela, R

    2007-03-02

    The suitability of an inexpensive polydimethysiloxane (PDMS) sorbent, produced on an industrial scale, for the extraction of polybrominated diphenyl ethers (PBDEs), from tetra- to hexabrominated congeners, from water samples was assessed. Experiments were carried out using samples spiked with a pentabromo diphenyl ether (pentaBDE) mixture, PDMS rods with a diameter of 2 mm and gas chromatography with micro-electron-capture detection (GC-micro-ECD). Influence of several variables on the efficiency of the enrichment step and the further desorption of the analytes was investigated in detail. The best performance was achieved in the headspace sorptive extraction (HSSE) mode, at 95 degrees C, using 80 mL water samples containing a 30% of sodium chloride. Extractions were performed overnight using disposable PDMS rods with a length of 10 mm (31 microL volume). Analytes were further recovered from the PDMS sorbent using just 1 mL of diethyl ether. This solvent was evaporated and extracts reconstituted with 25 microL of isooctane. Under final working conditions absolute extraction efficiencies from 69 to 93% and enrichment factors higher than 2200 folds were achieved for all species. The proposed method provided acceptable precisions (relative standard deviations values under 12%), correlation coefficients higher than 0.998 and the yield of the HSSE process remained constant for different water samples.

  20. Neutron Scattering Differential Cross Sections for 12C

    NASA Astrophysics Data System (ADS)

    Byrd, Stephen T.; Hicks, S. F.; Nickel, M. T.; Block, S. G.; Peters, E. E.; Ramirez, A. P. D.; Mukhopadhyay, S.; McEllistrem, M. T.; Yates, S. W.; Vanhoy, J. R.

    2016-09-01

    Because of the prevalence of its use in the nuclear energy industry and for our overall understanding of the interactions of neutrons with matter, accurately determining the effects of fast neutrons scattering from 12C is important. Previously measured 12C inelastic neutron scattering differential cross sections found in the National Nuclear Data Center (NNDC) show significant discrepancies (>30%). Seeking to resolve these discrepancies, neutron inelastic and elastic scattering differential cross sections for 12C were measured at the University of Kentucky Acceleratory Laboratory for incident neutron energies of 5.58, 5.83, and 6.04 MeV. Quasi mono-energetic neutrons were scattered off an enriched 12C target (>99.99%) and detected by a C6D6 liquid scintillation detector. Time-of-flight (TOF) techniques were used to determine scattered neutron energies and allowed for elastic/inelastic scattering distinction. Relative detector efficiencies were determined through direct measurements of neutrons produced by the 2H(d,n) and 3H(p,n) source reactions, and absolute normalization factors were found by comparing 1H scattering measurements to accepted NNDC values. This experimental procedure has been successfully used for prior neutron scattering measurements and seems well-suited to our current objective. Significant challenges were encountered, however, with measuring the neutron detector efficiency over the broad incident neutron energy range required for these measurements. Funding for this research was provided by the National Nuclear Security Administration (NNSA).

  1. Exploring exciton relaxation and multiexciton generation in PbSe nanocrystals using hyperspectral near-IR probing.

    PubMed

    Gdor, Itay; Sachs, Hanan; Roitblat, Avishy; Strasfeld, David B; Bawendi, Moungi G; Ruhman, Sanford

    2012-04-24

    Hyperspectral femtosecond transient absorption spectroscopy is employed to record exciton relaxation and recombination in colloidal lead selenide (PbSe) nanocrystals in unprecedented detail. Results obtained with different pump wavelengths and fluences are scrutinized with regard to three issues: (1) early subpicosecond spectral features due to "hot" excitons are analyzed in terms of suggested underlying mechanisms; (2) global kinetic analysis facilitates separation of the transient difference spectra into single, double, and triple exciton state contributions, from which individual band assignments can be tested; and (3) the transient spectra are screened for signatures of multiexciton generation (MEG) by comparing experiments with excitation pulses both below and well above the theoretical threshold for multiplication. For the latter, a recently devised ultrafast pump-probe spectroscopic approach is employed. Scaling sample concentrations and pump pulse intensities inversely with the extinction coefficient at each excitation wavelength overcomes ambiguities due to direct multiphoton excitation, uncertainties of absolute absorption cross sections, and low signal levels. As observed in a recent application of this method to InAs core/shell/shell nanodots, no sign of MEG was detected in this sample up to photon energy 3.7 times the band gap. Accordingly, numerous reports of efficient MEG in other samples of PbSe suggest that the efficiency of this process varies from sample to sample and depends on factors yet to be determined.

  2. Simple and specific colorimetric detection of Staphylococcus using its volatile 2-[3-acetoxy-4,4,14-trimethylandrost-8-en-17-yl] propanoic acid in the liquid phase and head space of cultures.

    PubMed

    Saranya, Raju; Aarthi, Raju; Sankaran, Krishnan

    2015-05-01

    Spread of drug-resistant Staphylococcus spp. into communities pose danger demanding effective non-invasive and non-destructive tools for its early detection and surveillance. Characteristic volatile organic compounds (VOCs) produced by bacteria offer new diagnostic targets and novel approaches not exploited so far in infectious disease diagnostics. Our search for such characteristic VOC for Staphylococcus spp. led to the depiction of 2-[3-acetoxy-4,4,14-trimethylandrost-8-en-17-yl] propanoic acid (ATMAP), a moderately volatile compound detected both in the culture and headspace when the organism was grown in tryptone soya broth (TSB) medium. A simple and inexpensive colorimetric method (colour change from yellow to orange) using methyl red as the pH indicator provided an absolutely specific way for identifying Staphylococcus spp., The assay performed in liquid cultures (7-h growth in TSB) as well as in the headspace of plate cultures (grown for 10 h on TSA) was optimised in a 96-well plate and 12-well plate formats, respectively, employing a set of positive and negative strains. Only Staphylococcus spp. showed the distinct colour change from yellow to orange due to the production of the above VOC while in the case of other organisms, the reagent remained yellow. The method validated using known clinical and environmental strains (56 including Staphylococcus, Proteus, Pseudomonas, Klebsiella, Bacillus, Shigella and Escherichia coli) was found to be highly efficient showing 100% specificity and sensitivity. Such simple methods of bacterial pathogen identification are expected to form the next generation tools for the control of infectious diseases through early detection and surveillance of causative agents.

  3. [Absolute numbers of peripheral blood CD34+ hematopoietic stem cells prior to a leukapheresis procedure as a parameter predicting the efficiency of stem cell collection].

    PubMed

    Galtseva, I V; Davydova, Yu O; Gaponova, T V; Kapranov, N M; Kuzmina, L A; Troitskaya, V V; Gribanova, E O; Kravchenko, S K; Mangasarova, Ya K; Zvonkov, E E; Parovichnikova, E N; Mendeleeva, L P; Savchenko, V G

    To identify a parameter predicting a collection of at least 2·106 CD34+ hematopoietic stem cells (HSC)/kg body weight per leukapheresis (LA) procedure. The investigation included 189 patients with hematological malignancies and 3 HSC donors, who underwent mobilization of stem cells with their subsequent collection by LA. Absolute numbers of peripheral blood leukocytes and CD34+ cells before a LA procedure, as well as a number of CD34+ cells/kg body weight (BW) in the LA product stored on the same day were determined in each patient (donor). There was no correlation between the number of leukocytes and that of stored CD34+ cells/kg BW. There was a close correlation between the count of peripheral blood CD34+ cells prior to LA and that of collected CD34+ cells calculated with reference to kg BW. The optimal absolute blood CD34+ cell count was estimated to 20 per µl, at which a LA procedure makes it possible to collect 2·106 or more CD34+ cells/kg BW.

  4. A rare gas optics-free absolute photon flux and energy analyzer to provide absolute photoionization rates of inflowing interstellar neutrals

    NASA Technical Reports Server (NTRS)

    Judge, Darrell L.

    1994-01-01

    A prototype spectrometer has been developed for space applications requiring long term absolute EUV photon flux measurements. The energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

  5. The JILA (Joint Institute for Laboratory Astrophysics) portable absolute gravity apparatus

    NASA Astrophysics Data System (ADS)

    Faller, J. E.; Guo, Y. G.; Gschwind, J.; Niebauer, T. M.; Rinker, R. L.; Xue, J.

    1983-08-01

    We have developed a new and highly portable absolute gravity apparatus based on the principles of free-fall laser interferometry. A primary concern over the past several years has been the detection, understanding, and elimination of systematic errors. In the Spring of 1982, we used this instrument to carry out a survey at twelve sites in the United States. Over a period of eight weeks, the instrument was driven a distance of nearly 20,000 km to sites in California, New Mexico, Colorado, Wyoming, Maryland, and Massachusetts. The time required to carry out a measurement at each location was typically one day. Over the next several years, our intention is to see absolute gravity measurements become both usable and used in the field. To this end, and in the context of cooperative research programs with a number of scientific institutes throughout the world, we are building additional instruments (incorporating further refinements) which are to be used for geodetic, geophysical, geological, and tectonic studies. With these new instruments we expect to improve (perhaps by a factor of two) on the 6-10 microgal accuracy of our present instrument. Today, one can make absolutely gravity measurements as accurately as - possibly even more accurately than - one can make relative measurements. Given reasonable success with the new instruments in the field, the last years of this century should see absolute gravity measurement mature both as a new geodetic data type and as a useful geophysical tool.

  6. Quantitative detection of RASSF1A DNA promoter methylation in tumors and serum of patients with serous epithelial ovarian cancer.

    PubMed

    Bondurant, Amy E; Huang, Zhiqing; Whitaker, Regina S; Simel, Lauren R; Berchuck, Andrew; Murphy, Susan K

    2011-12-01

    Detection of cell free tumor-specific DNA methylation has been proposed as a potentially useful noninvasive mechanism to detect malignancies, including ovarian cancer, and to monitor response to treatment. However, there are few easily implemented quantitative approaches available for DNA methylation analysis. Our objectives were to develop an absolute quantitative method for detection of DNA methylation using RASSF1A, a known target of promoter methylation in ovarian cancer, and test the ability to detect RASSF1A methylation in tumors and serum specimens of women with ovarian cancer. Bisulfite modified DNAs were subjected to real time PCR using nondiscriminatory PCR primers and a probe with sequence containing a single CpG site, theoretically able to capture the methylation status of that CpG for every allele within a given specimen. Input DNA was normalized to ACTB levels detected simultaneously by assay multiplexing. Methylation levels were established by comparison to results obtained from universally methylated DNA. The assay was able to detect one methylated RASSF1A allele in 100,000 unmethylated alleles. RASSF1A was methylated in 54 of 106 (51%) invasive serous ovarian cancers analyzed and methylation status was concordant in 20/20 matched preoperative serum-tumor pairs. Serial serum specimens taken over the course of treatment for 8 of 9 patients showed fluctuations in RASSF1A methylation concomitant with disease status. This novel assay provides a real-time PCR-based method for absolute quantitation of DNA methylation. Our results support feasibility of monitoring RASSF1A methylation from serum samples taken over the course of treatment from women with ovarian cancer. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Veridical mapping in savant abilities, absolute pitch, and synesthesia: an autism case study

    PubMed Central

    Bouvet, Lucie; Donnadieu, Sophie; Valdois, Sylviane; Caron, Chantal; Dawson, Michelle; Mottron, Laurent

    2014-01-01

    An enhanced role and autonomy of perception are prominent in autism. Furthermore, savant abilities, absolute pitch, and synesthesia are all more commonly found in autistic individuals than in the typical population. The mechanism of veridical mapping has been proposed to account for how enhanced perception in autism leads to the high prevalence of these three phenomena and their structural similarity. Veridical mapping entails functional rededication of perceptual brain regions to higher order cognitive operations, allowing the enhanced detection and memorization of isomorphisms between perceptual and non-perceptual structures across multiple scales. In this paper, we present FC, an autistic individual who possesses several savant abilities in addition to both absolute pitch and synesthesia-like associations. The co-occurrence in FC of abilities, some of them rare, which share the same structure, as well as FC’s own accounts of their development, together suggest the importance of veridical mapping in the atypical range and nature of abilities displayed by autistic people. PMID:24600416

  8. Magnetic Resonance Spectroscopy (MRS) of Prostatic Fluids for Early Detection of Prostate Cancer

    DTIC Science & Technology

    2005-10-01

    measured using external 1H-NMRS coils, increasing the practicality of the metabonomic approach. In conclusion, the absolute concentrations of the...Lindon, J.C., and Holmes, E. “ Metabonomics ”: understanding the metabolic responses of living systems to pathophysiological stimuli via multivariate

  9. Heterodyne detection of CO2 emission lines and wind velocities in the atmosphere of Venus

    NASA Technical Reports Server (NTRS)

    Betz, A. L.; Johnson, M. A.; Mclaren, R. A.; Sutton, E. C.

    1975-01-01

    Strong 10 micrometer line emission from (c-12)(o-16)2 in the upper atmosphere of Venus was detected by heterodyne techniques. Observations of the absolute Doppler shift of the emission features indicate mean zonal wind velocities less than 10 m/sec in the upper atmosphere near the equator. No evidence was found of the 100 m/sec wind velocity implied by the apparent 4-day rotation period of ultraviolet cloud features.

  10. The introduction of the absolute risk for the detection of fetal aneuploidies in the first-trimester screening.

    PubMed

    Padula, Francesco; Laganà, Antonio Simone; Vitale, Salvatore Giovanni; D'Emidio, Laura; Coco, Claudio; Giannarelli, Diana; Cariola, Maria; Favilli, Alessandro; Giorlandino, Claudio

    2017-05-01

    Maternal age is a crucial factor in fetal aneuploidy screening, resulting in an increased rate of false-positive cases in older women and false-negative cases in younger women. The absolute risk (AR) is the simplest way to eliminate the background maternal age risk, as it represents the amount of improvement of the combined risk from the maternal background risk. The aim of this work is to assess the performance of the AR in the combined first-trimester screening for aneuploidies. A retrospective validation of the AR in the combined first-trimester screening for fetal aneuploidies, in an unselected population at Altamedica Fetal-Maternal Medical Center in Rome, between March 2007 and December 2008. Of 3845 women included in the study, we had a complete follow-up on 2984. We evaluated that an AR < 3 would individuate 22 of 23 cases of aneuploidy with a detection rate of 95.7% (95%CI 87.3-100), a false-positive rate of 8.7% (95%CI 7.7-9.7) and a false-negative rate of 4.3% (95%CI 0-12.7). In our study, the AR ameliorates the detection rate for aneuploidy. Further research and a prospective study on a larger population would help us to improve the AR in detecting most cases of aneuploidy.

  11. Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Staples, P.A.; Egan, J.J.; Kegel, G.H.R.

    1994-06-01

    Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scatteringmore » cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fell, Harrison; Kaffine, Daniel; Steinberg, Daniel

    We investigate the role of energy efficiency in rate-based emissions intensity standards, a particularly policy-relevant consideration given that the Environmental Protection Agency's Clean Power Plan allows crediting of electricity savings as a means of complying with state-specific emissions standards. We show that with perfectly inelastic energy services demand, crediting efficiency measures can recover the first-best allocation. However, when demand for energy services exhibits some elasticity, crediting energy efficiency can no longer recover first-best. While crediting removes the relative distortion between energy generation and energy efficiency, it distorts the absolute level of energy services. Building on these results, we derive themore » conditions determining the second-best intensity standard and crediting rule. Simulations calibrated to the electricity sector in Texas find that while some form of crediting is generally welfare-improving, the proposed one-for-one crediting of energy savings is unlikely to achieve efficient outcomes.« less

  13. Final Report: Utilizing Alternative Fuel Ignition Properties to Improve SI and CI Engine Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wooldridge, Margaret; Boehman, Andre; Lavoie, George

    Experimental and modeling studies were completed to explore leveraging physical and chemical fuel properties for improved thermal efficiency of internal combustion engines. Fundamental studies of the ignition chemistry of ethanol and iso-octane blends and constant volume spray chamber studies of gasoline and diesel sprays supported the core research effort which used several reciprocating engine platforms. Single cylinder spark ignition (SI) engine studies were carried out to characterize the impact of ethanol/gasoline, syngas (H 2 and CO)/gasoline and other oxygenate/gasoline blends on engine performance. The results of the single-cylinder engine experiments and other data from the literature were used to trainmore » a GT Power model and to develop a knock criteria based on reaction chemistry. The models were used to interpret the experimental results and project future performance. Studies were also carried out using a state of the art, direct injection (DI) turbocharged multi- cylinder engine with piezo-actuated fuel injectors to demonstrate the promising spray and spark timing strategies from single-cylinder engine studies on the multi-cylinder engine. Key outcomes and conclusions of the studies were: 1. Efficiency benefits of ethanol and gasoline fuel blends were consistent and substantial (e.g. 5-8% absolute improvement in gross indicated thermal efficiency (GITE)). 2. The best ethanol/gasoline blend (based on maximum thermal efficiency) was determined by the engine hardware and limits based on component protection (e.g. peak in-cylinder pressure or maximum turbocharger inlet temperature) – and not by knock limits. Blends with <50% ethanol delivered significant thermal efficiency gains with conventional SI hardware while maintain good safety integrity to the engine hardware. 3. Other compositions of fuel blends including syngas (H 2 and CO) and other dilution strategies provided significant efficiency gains as well (e.g. 5% absolute improvement in ITE). 4. When the combination of engine and fuel system is not knock limited, multiple fuel injection events maintain thermal efficiency while improving engine-out emissions (e.g. CO, UHC, and particulate number).« less

  14. Channel specific rate constants for reactions of O(1D) with HCl and HBr

    NASA Technical Reports Server (NTRS)

    Wine, P. H.; Wells, J. R.; Ravishankara, A. R.

    1986-01-01

    The absolute rate coefficients and product yields for reactions of O(1D) with HCl(1) and HBr(2) at 287 K are presently determined by means of the time-resolved resonance fluorescence detection of O(3P) and H(2S) in conjunction with pulsed laser photolysis of O3/HX/He mixtures. Total rate coefficients for O(1D) removal are found to be, in units of 10 to the -10th cu cm/molecule per sec, k(1) = 1.50 + or - 0.18 and k(2) 1.48 + or - 0.16; the absolute accuracy of these rate coefficients is estimated to be + or - 20 percent.

  15. Dark Light, Rod Saturation, and the Absolute and Incremental Sensitivity of Mouse Cone Vision

    PubMed Central

    Naarendorp, Frank; Esdaille, Tricia M.; Banden, Serenity M.; Andrews-Labenski, John; Gross, Owen P.; Pugh, Edward N.

    2012-01-01

    Visual thresholds of mice for the detection of small, brief targets were measured with a novel behavioral methodology in the dark and in the presence of adapting lights spanning ∼8 log10 units of intensity. To help dissect the contributions of rod and cone pathways, both wild-type mice and mice lacking rod (Gnat1−/−) or cone (Gnat2cpfl3) function were studied. Overall, the visual sensitivity of mice was found to be remarkably similar to that of the human peripheral retina. Rod absolute threshold corresponded to 12-15 isomerized pigment molecules (R*) in image fields of 800 to 3000 rods. Rod “dark light” (intrinsic retinal noise in darkness) corresponded to that estimated previously from single-cell recordings, 0.012R*s−1rod−1, indicating that spontaneous thermalisomerizations are responsible. Psychophysical rod saturation was measured for the first time in a nonhman species and found to be very similar to that of the human rod monochromat. Cone threshold corresponded to ∼5 R* cone−1 in an image field of 280 cones. Cone dark light was equivalent to ∼5000 R*s−1 cone−1, consistent with primate single-cell data but 100-fold higher than predicted by recent measurements of the rate of thermal isomerization of mouse cone opsins, indicating that nonopsin sources of noise determine cone threshold. The new, fully automated behavioral method is based on the ability of mice to learn to interrupt spontaneous wheel running on the presentation of a visual cue and provides an efficient and highly reliable means of examining visual function in naturally behaving normal and mutant mice. PMID:20844144

  16. Effect of feed-related farm characteristics on relative values of genetic traits in dairy cows to reduce greenhouse gas emissions along the chain.

    PubMed

    Van Middelaar, C E; Berentsen, P B M; Dijkstra, J; Van Arendonk, J A M; De Boer, I J M

    2015-07-01

    Breeding has the potential to reduce greenhouse gas (GHG) emissions from dairy farming. Evaluating the effect of a 1-unit change (i.e., 1 genetic standard deviation improvement) in genetic traits on GHG emissions along the chain provides insight into the relative importance of genetic traits to reduce GHG emissions. Relative GHG values of genetic traits, however, might depend on feed-related farm characteristics. The objective of this study was to evaluate the effect of feed-related farm characteristics on GHG values by comparing the values of milk yield and longevity for an efficient farm and a less efficient farm. The less efficient farm did not apply precision feeding and had lower feed production per hectare than the efficient farm. Greenhouse gas values of milk yield and longevity were calculated by using a whole-farm model and 2 different optimization methods. Method 1 optimized farm management before and after a change in genetic trait by maximizing labor income; the effect on GHG emissions (i.e., from production of farm inputs up to the farm gate) was considered a side effect. Method 2 optimized farm management after a change in genetic trait by minimizing GHG emissions per kilogram of milk while maintaining labor income and milk production at least at the level before the change in trait; the effect on labor income was considered a side effect. Based on maximizing labor income (method 1), GHG values of milk yield and longevity were, respectively, 279 and 143kg of CO2 equivalents (CO2e)/unit change per cow per year on the less efficient farm, and 247 and 210kg of CO2e/unit change per cow per year on the efficient farm. Based on minimizing GHG emissions (method 2), GHG values of milk yield and longevity were, respectively, 538 and 563kg of CO2e/unit change per cow per year on the less efficient farm, and 453 and 441kg of CO2e/unit change per cow per year on the efficient farm. Sensitivity analysis showed that, for both methods, the absolute effect of a change in genetic trait depends on model inputs, including prices and emission factors. Substantial changes in relative importance between traits due to a change in model inputs occurred only in case of maximizing labor income. We concluded that assumptions regarding feed-related farm characteristics affect the absolute level of GHG values, as well as the relative importance of traits to reduce emissions when using a method based on maximizing labor income. This is because optimizing farm management based on maximizing labor income does not give any incentive for lowering GHG emissions. When using a method based on minimizing GHG emissions, feed-related farm characteristics affected the absolute level of the GHG values, but the relative importance of the traits scarcely changed: at each level of efficiency, milk yield and longevity were equally important. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Tensiomyographical responses to accelerometer loads in female collegiate basketball players.

    PubMed

    Peterson, Kyle D; Quiggle, Gabriela T

    2017-12-01

    The purpose of the present study was to characterise the relationship between relative versus absolute internal and external loads in collegiate basketball players throughout the course of a season. Five Division I basketball players wore triaxial accelerometers throughout the 2015-2016 season and were tensiomyographically assessed weekly. One-way repeated-measure analysis of variance (RM ANOVA) with least-significant-difference (LSD) pairwise comparisons was used to determine which absolute weekly loads were different across the season. Cohen's d was used to supplement the determination of meaningful relative load changes. Overall RM ANOVA models suggest absolute external load differences occurred (PlayerLoad™ F = 17.63; IMA™ F = 31.63). Two-way RM ANOVA models revealed main effect differences were revealed between muscle groups for Tc (F = 9.11) and Dm (F = 3.25). Meaningful relative load changes between weeks were observed for both external and internal. The present study observed that tensiomyography utilised as a tool to monitor internal load may be more suitable for detecting fatigue from relative external load changes versus absolute load attained. Limiting weekly training volume changes to ≤10% may maintain appropriate adaptation. Mediolateral plane IMA™ and adductor longus muscle group may be pertinent metrics when monitoring female collegiate basketball athletes.

  18. Improved absolute calibration of LOPES measurements and its impact on the comparison with REAS 3.11 and CoREAS simulations

    NASA Astrophysics Data System (ADS)

    Apel, W. D.; Arteaga-Velázquez, J. C.; Bähren, L.; Bekk, K.; Bertaina, M.; Biermann, P. L.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Cantoni, E.; Chiavassa, A.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Falcke, H.; Fuchs, B.; Gemmeke, H.; Grupen, C.; Haungs, A.; Heck, D.; Hiller, R.; Hörandel, J. R.; Horneffer, A.; Huber, D.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Krömer, O.; Kuijpers, J.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Melissas, M.; Morello, C.; Nehls, S.; Oehlschläger, J.; Palmieri, N.; Pierog, T.; Rautenberg, J.; Rebel, H.; Roth, M.; Rühle, C.; Saftoiu, A.; Schieler, H.; Schmidt, A.; Schoo, S.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Weindl, A.; Wochele, J.; Zabierowski, J.; Zensus, J. A.

    2016-02-01

    LOPES was a digital antenna array detecting the radio emission of cosmic-ray air showers. The calibration of the absolute amplitude scale of the measurements was done using an external, commercial reference source, which emits a frequency comb with defined amplitudes. Recently, we obtained improved reference values by the manufacturer of the reference source, which significantly changed the absolute calibration of LOPES. We reanalyzed previously published LOPES measurements, studying the impact of the changed calibration. The main effect is an overall decrease of the LOPES amplitude scale by a factor of 2.6 ± 0.2, affecting all previously published values for measurements of the electric-field strength. This results in a major change in the conclusion of the paper 'Comparing LOPES measurements of air-shower radio emission with REAS 3.11 and CoREAS simulations' published by Apel et al. (2013) : With the revised calibration, LOPES measurements now are compatible with CoREAS simulations, but in tension with REAS 3.11 simulations. Since CoREAS is the latest version of the simulation code incorporating the current state of knowledge on the radio emission of air showers, this new result indicates that the absolute amplitude prediction of current simulations now is in agreement with experimental data.

  19. THE USE OF I$sup 125$ LABELED DIIODOFLUORESCEIN IN THE DETECTION OF HUMAN INTRAOCULAR NEOPLASMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goren, S.B.; Newell, E.W.; Brizel, H.E.

    The new method which is described is believed to be superior to the usual method for detection of intraocular tumors using P/sup 32/. Because of the limited penetration of beta rays, the use of P/sup 32/ imposes relatively strict geometric restrictions and its usefulness in posterior-segment tumors is limited. The patient receives a single intravenous injection of 5.0 mu c/kg body weight of diiodofluorescein-I/sup 125/, the specific activity of which is 17 mg/mc. External counting over each closed eye is carried out with a hand scintillation counter 1, 5, 8, and 24 hr after injection. Ocular counts are performed bymore » resting the window of the counter against the closed lids; the cavernous sinus is measured by placing the counter just above the bridge of the nose. ln the 17 patients studied, eyes with neoplasms contained at least 23% more radioactivity after 8 hr than did the healthy eye. Control eyes, not containing neoplasms (idiopathic retinal detachment, retinoschisis, benign nevus, macular degeneration, phthisis bulbi, absolute glaucoma), showed less than a 13% differential. One false negative test was obtained, a patient with a metastatic bronchogenic adenocarcinoma to the choroid; no false positives were seen. Diiodofluorescein labeled with I/sup 131/ has been widely used as a diagnostic aid in suspected intracranial neoplasms. However, since the gamma rays of I/sup 131/ have a half-value layer in tissue of 6.9 cm, it has not been helpful in ocular disease; the gamma rays arising from the cavernous sinus interfere with accurate counting of intraocular radiation. I/sup 125/ decays by a complicated scheme, the most important as far as ocular studies are concerned being soft photons of 27.3 and 35.4 kev energies. It has a half-value layer in tissue of 1.9 to 2.5 cm. Therefore, it is feasible to measure radiation of the posterior globe with only minimal interference from radiation arising in the brain sinuses. Its half-life of 60 days results in a greatly increased shelf-life of tagged compounds than when I/sup 131/ is used. Additionally, it has a lower energy of radiation than I/sup 131/ which reduces shielding requirements and permits more efficient detector design. These factors permit enhanced counting efficiency and scanning resolution and lead to a decreased dosage of radiation to the patient. It is thus permissible to use the compound in children in whom P/sup 32/ counting is generally considered contraindicated. However, although the total-body irradiation received during this test is not excessive, it has not been used in pregnant women. The administration of Lugol's solution prior to the test prevents excessive concentration of any free circulating radioactive iodine in the thyroid gland. Diiodofluorescein-I/sup 125/ is not retained by intraocular neoplasms for prolonged periods of time, the most significant counts appearing 8 hr after intravenous injection. About 50% of the injected dose is excreted in the urine and feces within the first 24 hr after injection. The absolute count found in the eye after 8 hr is in the order of 40,000 cpm. After 24 hr, this decreases to approximates 15,000 cpm. The ratio of counts over liver, thyroid, eye, and cavernous sinus is about 4 : 2 : 1 : 0.4. The ratio of counts between the 2 eyes is more significant than the absolute number of counts. This may limit the usefulness of this procedure in monocular patients. (H.H.D.)« less

  20. Characterization of an ultraviolet imaging detector with high event rate ROIC (HEROIC) readout

    NASA Astrophysics Data System (ADS)

    Nell, Nicholas; France, Kevin; Harwit, Alex; Bradley, Scott; Franka, Steve; Freymiller, Ed; Ebbets, Dennis

    2016-07-01

    We present characterization results from a photon counting imaging detector consisting of one microchannel plate (MCP) and an array of two readout integrated circuits (ROIC) that record photon position. The ROICs used in the position readout are the high event rate ROIC (HEROIC) devices designed to handle event rates up to 1 MHz per pixel, recently developed by the Ball Aerospace and Technologies Corporation in collaboration with the University of Colorado. An opaque cesium iodide (CsI) photocathode sensitive in the far-ultraviolet (FUV; 122-200 nm), is deposited on the upper surface of the MCP. The detector is characterized in a chamber developed by CU Boulder that is capable of illumination with vacuum-ultraviolet (VUV) monochromatic light and measurement of absolute ux with a calibrated photodiode. Testing includes investigation of the effects of adjustment of internal settings of the HEROIC devices including charge threshold, gain, and amplifier bias. The detector response to high count rates is tested. We report initial results including background, uniformity, and quantum detection efficiency (QDE) as a function of wavelength.

  1. 2-COLOR Pupil Imaging Method to Detect Stellar Oscillations

    NASA Astrophysics Data System (ADS)

    Costantino, Sigismondi; Alessandro, Cacciani; Mauro, Dolci; Stuart, Jeffries; Eric, Fossat; Ludovico, Cesario; Paolo, Rapex; Luca, Bertello; Ferenc, Varadi; Wolfgang, Finsterle

    Stellar intensity oscillations from the ground are strongly affected by atmospheric noise. For solar-type stars even Antarctic scintillation noise is still overwhelming. We proposed and tested a differential method that images on the same CCD detector two-color pupils of the telescope in order to compensate for intensity sky fluctuations guiding and saturation problems. SOHO data reveal that our method has an efficiency of 70% respect to the absolute amplitude variations. Using two instruments at Dome C and South Pole we can further minimize atmospheric color noise with cross-spectrum methods. This way we also decrease the likelihood of gaps in the data string due to bad weather. Observationally while waiting for the South Pole/Dome-C sites we are carrying on tests from available telescopes and Big Bear Mt. Wilson Teramo Milano. On the data analysis side we use the Random Lag Singular Cross-Spectrum Analysis which eliminates noise from the observed signal better than traditional Fourier transform. This method is also well-suited for extracting common oscillatory components from two or more observations including their relative phases as we are planning to do

  2. Up-and-down-shaker-assisted dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry for the determination of fungicides in wine.

    PubMed

    Chu, Shang-Ping; Tseng, Wan-Chi; Kong, Po-Hsin; Huang, Chun-Kai; Chen, Jung-Hsuan; Chen, Pai-Shan; Huang, Shang-Da

    2015-10-15

    An up-and-down-shaker-assisted dispersive liquid-liquid microextraction (UDSA-DLLME) method coupled with gas chromatography-mass spectrometry was developed for the determination of fungicides (cyprodinil, procymidone, fludioxonil, flusilazole, benalaxyl, and tebuconazole) in wine. The developed method requires 11 μL of 1-octanol without the need for dispersive solvents. The total extraction time was approximately 3 min. Under optimum conditions, the linear range of the method was 0.05-100 μg L(-1) for all fungicides and the limit of detection was 0.007-0.025 μg L(-1). The absolute and relative recoveries were 31-83% and 83-107% for white wine, respectively, and 32-85% and 83-108% for red wine, respectively. The intra-day and inter-day precision were 0.5-7.5% and 0.7-6.1%, respectively. Our developed method had good sensitivity and high extraction efficiency. UDSA-DLLME is a desirable method in terms of performance and speed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Precision Isotope Shift Measurements in Calcium Ions Using Quantum Logic Detection Schemes.

    PubMed

    Gebert, Florian; Wan, Yong; Wolf, Fabian; Angstmann, Christopher N; Berengut, Julian C; Schmidt, Piet O

    2015-07-31

    We demonstrate an efficient high-precision optical spectroscopy technique for single trapped ions with nonclosed transitions. In a double-shelving technique, the absorption of a single photon is first amplified to several phonons of a normal motional mode shared with a cotrapped cooling ion of a different species, before being further amplified to thousands of fluorescence photons emitted by the cooling ion using the standard electron shelving technique. We employ this extension of the photon recoil spectroscopy technique to perform the first high precision absolute frequency measurement of the 2D(3/2)→2P(1/2) transition in calcium, resulting in a transition frequency of f=346 000 234 867(96)  kHz. Furthermore, we determine the isotope shift of this transition and the 2S(1/2)→2P(1/2) transition for 42Ca+, 44Ca+, and 48Ca+ ions relative to 40Ca+ with an accuracy below 100 kHz. Improved field and mass shift constants of these transitions as well as changes in mean square nuclear charge radii are extracted from this high resolution data.

  4. Sympathetic Nerve Activity and Heart Rate Variability During Severe Hemorrhagic Shock in Sheep

    DTIC Science & Technology

    2007-01-01

    2000, Boebingen, Germany). 2.3. Experimental protocol After a steady nerve signal was obtained (verified visually and by auscultation ) the experimental...both visually and by auscultation . Automatic amplitude-based detection of sym- pathetic bursts was performed with WinCPRS software (Absolute Aliens Oy

  5. 40 CFR 60.5200 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... control if the conditions of paragraph (a)(7)(i)(A) or (a)(7)(i)(B) of this section are met. (A) The zero... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  6. 40 CFR 60.5200 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... control if the conditions of paragraph (a)(7)(i)(A) or (a)(7)(i)(B) of this section are met. (A) The zero... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  7. 40 CFR 63.1350 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... alkali bypass PMCDs. (i) The temperature recorder response range must include zero and 1.5 times the... provide output of relative or absolute particulate matter loadings. (v) The bag leak detection system must... period. (7) The flow rate sensor must have provisions to determine the daily zero and upscale calibration...

  8. 40 CFR 60.5200 - How do I develop a site-specific monitoring plan for my continuous monitoring, bag leak detection...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... control if the conditions of paragraph (a)(7)(i)(A) or (a)(7)(i)(B) of this section are met. (A) The zero... representative of the relative or absolute particulate matter loadings for each exhaust stack, roof vent, or...

  9. A highly efficient, high-throughput lipidomics platform for the quantitative detection of eicosanoids in human whole blood.

    PubMed

    Song, Jiao; Liu, Xuejun; Wu, Jiejun; Meehan, Michael J; Blevitt, Jonathan M; Dorrestein, Pieter C; Milla, Marcos E

    2013-02-15

    We have developed an ultra-performance liquid chromatography-multiple reaction monitoring/mass spectrometry (UPLC-MRM/MS)-based, high-content, high-throughput platform that enables simultaneous profiling of multiple lipids produced ex vivo in human whole blood (HWB) on treatment with calcium ionophore and its modulation with pharmacological agents. HWB samples were processed in a 96-well plate format compatible with high-throughput sample processing instrumentation. We employed a scheduled MRM (sMRM) method, with a triple-quadrupole mass spectrometer coupled to a UPLC system, to measure absolute amounts of 122 distinct eicosanoids using deuterated internal standards. In a 6.5-min run, we resolved and detected with high sensitivity (lower limit of quantification in the range of 0.4-460 pg) all targeted analytes from a very small HWB sample (2.5 μl). Approximately 90% of the analytes exhibited a dynamic range exceeding 1000. We also developed a tailored software package that dramatically sped up the overall data quantification and analysis process with superior consistency and accuracy. Matrix effects from HWB and precision of the calibration curve were evaluated using this newly developed automation tool. This platform was successfully applied to the global quantification of changes on all 122 eicosanoids in HWB samples from healthy donors in response to calcium ionophore stimulation. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Detection and quantification of extracellular microRNAs in murine biofluids

    PubMed Central

    2014-01-01

    Background MicroRNAs (miRNAs) are short RNA molecules which regulate gene expression in eukaryotic cells, and are abundant and stable in biofluids such as blood serum and plasma. As such, there has been heightened interest in the utility of extracellular miRNAs as minimally invasive biomarkers for diagnosis and monitoring of a wide range of human pathologies. However, quantification of extracellular miRNAs is subject to a number of specific challenges, including the relatively low RNA content of biofluids, the possibility of contamination with serum proteins (including RNases and PCR inhibitors), hemolysis, platelet contamination/activation, a lack of well-established reference miRNAs and the biochemical properties of miRNAs themselves. Protocols for the detection and quantification of miRNAs in biofluids are therefore of high interest. Results The following protocol was validated by quantifying miRNA abundance in C57 (wild-type) and dystrophin-deficient (mdx) mice. Important differences in miRNA abundance were observed depending on whether blood was taken from the jugular or tail vein. Furthermore, efficiency of miRNA recovery was reduced when sample volumes greater than 50 μl were used. Conclusions Here we describe robust and novel procedures to harvest murine serum/plasma, extract biofluid RNA, amplify specific miRNAs by RT-qPCR and analyze the resulting data, enabling the determination of relative and absolute miRNA abundance in extracellular biofluids with high accuracy, specificity and sensitivity. PMID:24629058

  11. Validation a solid-phase extraction-HPLC method for determining the migration behaviour of five aromatic amines from packaging bags into seafood simulants.

    PubMed

    OuYang, Xiao-Kun; Luo, Yu-Yang; Wang, Yang-Guang; Yang, Li-Ye

    2014-01-01

    The simultaneous determination of five aromatic amines and their potential migration from packaging bags into seafood simulants were investigated. A validated HPLC method was developed for the separation and qualification of five aromatic amines in seafood simulants. By combining solid-phase extraction (SPE), these amines were efficiently separated on a Halo C18 column (150 × 4.6 mm i.d., 2.7 μm, particle size) using a mobile phase of methanol/phosphate buffer solution (5 mmol l(-1), pH 6.9) with gradient elution. The linear range was 0.1-10.0 mg l(-1); the absolute recoveries ranged from 85.3% to 98.4%; and the limits of detection of the five aromatic amines were between 0.015 and 0.08 mg l(-1). In this work the migration profile of aromatic amines from black plastic bags was investigated at temperatures of 4°C with water, 3% acetic acid solution, 10% ethanol solution and 50% ethanol solution as seafood simulants, respectively. The migration of the five aromatic amines under different conditions showed that residual o-methoxyaniline, p-chloroaniline, aniline and 2,6-dimethylaniline leaching from black plastic bags increased with incubation time. No detectable 3,3´-dimethylbenzidine was found to leach from the bags.

  12. Integrating scales of seagrass monitoring to meet conservation needs

    USGS Publications Warehouse

    Neckles, Hilary A.; Kopp, Blaine S.; Peterson, Bradley J.; Pooler, Penelope S.

    2012-01-01

    We evaluated a hierarchical framework for seagrass monitoring in two estuaries in the northeastern USA: Little Pleasant Bay, Massachusetts, and Great South Bay/Moriches Bay, New York. This approach includes three tiers of monitoring that are integrated across spatial scales and sampling intensities. We identified monitoring attributes for determining attainment of conservation objectives to protect seagrass ecosystems from estuarine nutrient enrichment. Existing mapping programs provided large-scale information on seagrass distribution and bed sizes (tier 1 monitoring). We supplemented this with bay-wide, quadrat-based assessments of seagrass percent cover and canopy height at permanent sampling stations following a spatially distributed random design (tier 2 monitoring). Resampling simulations showed that four observations per station were sufficient to minimize bias in estimating mean percent cover on a bay-wide scale, and sample sizes of 55 stations in a 624-ha system and 198 stations in a 9,220-ha system were sufficient to detect absolute temporal increases in seagrass abundance from 25% to 49% cover and from 4% to 12% cover, respectively. We made high-resolution measurements of seagrass condition (percent cover, canopy height, total and reproductive shoot density, biomass, and seagrass depth limit) at a representative index site in each system (tier 3 monitoring). Tier 3 data helped explain system-wide changes. Our results suggest tiered monitoring as an efficient and feasible way to detect and predict changes in seagrass systems relative to multi-scale conservation objectives.

  13. Perfusion-weighted magnetic resonance imaging detects recurrent isolated vertigo caused by cerebral hypoperfusion.

    PubMed

    Xu, Xiaowei; Jiang, Li; Luo, Man; Li, Jiaoxing; Li, Weidong; Sheng, Wenli

    2015-06-01

    The etiology of isolated vertigo has been a substantial diagnostic challenge for both neurologists and otolaryngologists. This study was designed to detect recurrent isolated vertigo due to cerebral hypoperfusion using perfusion-weighted magnetic resonance imaging (PWI). We recruited isolated vertigo patients whose clinical condition was suspected to be caused by hypodynamics of the brain; these individuals formed the case group. We generated two additional groups: a negative group composed of vertigo patients whose symptoms were caused by problems associated with the ear and a healthy control group. Each subject underwent PWI, and seven regions of interest (ROIs) were chosen. The relative cerebral blood volume (rCBV), relative cerebral blood flow (rCBF), and mean transit time (MTT) were obtained from each ROI. We further calculated the absolute difference of relative parameter values between two mirrored ROIs. The significant difference in the relative MTT from the mirrored cerebellar ROI (|rMTTleft-right|) of the case group was larger than those from the negative and healthy control groups (p = 0.026 and p = 0.038, respectively). Signal differences in |rrCBVleft-right| and |rrCBFleft-right| were not found among the three groups. In summary, disequilibrium in the rMTT of the bilateral cerebellum in the case group implied that hypoperfusion of the posterior circulation could trigger recurrent isolated vertigo and could be shown efficiently using PWI.

  14. Analysis of non-steroidal anti-inflammatory drugs in milk using QuEChERS and liquid chromatography coupled to mass spectrometry: triple quadrupole versus Q-Orbitrap mass analyzers.

    PubMed

    Rúbies, Antoni; Guo, Lili; Centrich, Francesc; Granados, Mercè

    2016-08-01

    We developed a Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method for the high throughput determination of 10 non-steroidal anti-inflammatory drugs (NSAIDs) in milk samples using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) with a triple quadrupole (QqQ) instrument and an electrospray ionization (ESI) source. The new extraction procedure is highly efficient, and we obtained absolute recoveries in the range 78.1-97.1 % for the extraction and clean-up steps. Chromatographic separation is performed in the gradient mode with a biphenyl column and acidic mobile phases consisting of water and acetonitrile containing formic acid. The chromatographic run time was about 12 min, and NSAID peaks showed a good symmetry factor. For MS/MS detection, we used multiple reaction monitoring (MRM) mode, using ESI in both positive and negative modes. Our method has been validated in compliance with the European Commission Decision 657/2002/EC, and we obtained very satisfactory results in inter-laboratory testing. Furthermore, we explored the use of a hybrid high resolution mass spectrometer, combining a quadrupole and an Orbitrap mass analyzer, for high resolution (HR) MS/MS detection of NSAIDs. We achieved lower NSAID quantification limits with Q-Orbitrap high resolution mass spectrometry (HRMS/MS) detection than those achieved with the QqQ instrument; however, its main feature is its very high selectivity, which makes HRMS/MS particularly suitable for confirmatory analysis.

  15. High-fidelity target sequencing of individual molecules identified using barcode sequences: de novo detection and absolute quantitation of mutations in plasma cell-free DNA from cancer patients.

    PubMed

    Kukita, Yoji; Matoba, Ryo; Uchida, Junji; Hamakawa, Takuya; Doki, Yuichiro; Imamura, Fumio; Kato, Kikuya

    2015-08-01

    Circulating tumour DNA (ctDNA) is an emerging field of cancer research. However, current ctDNA analysis is usually restricted to one or a few mutation sites due to technical limitations. In the case of massively parallel DNA sequencers, the number of false positives caused by a high read error rate is a major problem. In addition, the final sequence reads do not represent the original DNA population due to the global amplification step during the template preparation. We established a high-fidelity target sequencing system of individual molecules identified in plasma cell-free DNA using barcode sequences; this system consists of the following two steps. (i) A novel target sequencing method that adds barcode sequences by adaptor ligation. This method uses linear amplification to eliminate the errors introduced during the early cycles of polymerase chain reaction. (ii) The monitoring and removal of erroneous barcode tags. This process involves the identification of individual molecules that have been sequenced and for which the number of mutations have been absolute quantitated. Using plasma cell-free DNA from patients with gastric or lung cancer, we demonstrated that the system achieved near complete elimination of false positives and enabled de novo detection and absolute quantitation of mutations in plasma cell-free DNA. © The Author 2015. Published by Oxford University Press on behalf of Kazusa DNA Research Institute.

  16. Radiometric Calibration of the NASA Advanced X-Ray Astrophysics Facility

    NASA Technical Reports Server (NTRS)

    Kellogg, Edwin M.

    1999-01-01

    We present the results of absolute calibration of the quantum efficiency of soft x-ray detectors performed at the PTB/BESSY beam lines. The accuracy goal is 1%. We discuss the implementation of that goal. These detectors were used as transfer standards to provide the radiometric calibration of the AXAF X-ray observatory, to be launched in April 1999.

  17. Non-cooperative Brownian donkeys: A solvable 1D model

    NASA Astrophysics Data System (ADS)

    Jiménez de Cisneros, B.; Reimann, P.; Parrondo, J. M. R.

    2003-12-01

    A paradigmatic 1D model for Brownian motion in a spatially symmetric, periodic system is tackled analytically. Upon application of an external static force F the system's response is an average current which is positive for F < 0 and negative for F > 0 (absolute negative mobility). Under suitable conditions, the system approaches 100% efficiency when working against the external force F.

  18. Evaluation of the ion-density measurements by the Indian satellite SROSS-C2

    NASA Astrophysics Data System (ADS)

    Subrahmanyam, P.; Jain, A. R.; Maini, H. K.; Bahl, M.; Das, Rupesh M.; Garg, S. C.; Niranjan, K.

    2010-12-01

    The ion and electron F region plasma measurements made by the ion and electron Retarding Potential Analyzers (RPAs) onboard the Indian satellite SROSS-C2, have yielded excellent data set over the Indian region for more than half a solar cycle, after the SROSS-C2 launch in May 1994. The absolute ion density, ion temperature, and ion composition parameters are derived from these in situ measurements and used by many workers. In this paper the absolute values of ion density derived from the ion RPA measurements are compared and evaluated with the measurements made by ground-based ionosondes located in the Indian region and close to the SROSS-C2 orbital path. It is shown that a slight adjustment in efficiency factor of the ion RPA sensor brings the in situ measurements much closer to those obtained from the ground-based ionosonde measurements taking into account the model calculations. It may be mentioned that this is a correction to the ion density measurement by SROSS-C2 by a fixed proportion (14-11.4%). The effect of change in efficiency factor on the ion current, which is used to deduce the ion number density, is demonstrated and discussed.

  19. Determination of photoionization cross-sections of different organic molecules using gas chromatography coupled to single-photon ionization (SPI) time-of-flight mass spectrometry (TOF-MS) with an electron-beam-pumped rare gas excimer light source (EBEL): influence of molecular structure and analytical implications.

    PubMed

    Eschner, Markus S; Zimmermann, Ralf

    2011-07-01

    This work describes a fast and reliable method for determination of photoionization cross-sections (PICS) by means of gas chromatography (GC) coupled to single-photon ionization mass spectrometry (SPI-MS). Photoionization efficiency (PIE) data for 69 substances was obtained at a photon energy of 9.8 ± 0.4 eV using an innovative electron-beam-pumped rare gas excimer light source (EBEL) filled with argon. The investigated analytes comprise 12 alkylbenzenes as well as 11 other substituted benzenes, 23 n-alkanes, ten polyaromatic hydrocarbons, seven aromatic heterocycles, and six polyaromatic heterocycles. Absolute PICS for each substance at 9.8 eV are calculated from the relative photoionization efficiencies of the compounds with respect to benzene, whose photoionization cross-section data is well known. Furthermore, a direct correlation between the type of benzene substituents and their absolute PICS is presented and discussed in depth. Finally, comparison of previously measured photoionization cross-sections for 20 substances shows good agreement with the data of the present work.

  20. Production mechanism of atomic nitrogen in atmospheric pressure pulsed corona discharge measured using two-photon absorption laser-induced fluorescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teramoto, Yoshiyuki; Ono, Ryo; Oda, Tetsuji

    To study the production mechanism of atomic nitrogen, the temporal profile and spatial distribution of atomic nitrogen are measured in atmospheric pressure pulsed positive corona discharge using two-photon absorption laser-induced fluorescence. The absolute atomic nitrogen density in the streamer filaments is estimated from decay rate of atomic nitrogen in N{sub 2} discharge. The results indicate that the absolute atomic nitrogen density is approximately constant against discharge energy. When the discharge voltage is 21.5 kV, production yield of atomic nitrogen produced by an N{sub 2} discharge pulse is estimated to be 2.9 - 9.8 Multiplication-Sign 10{sup 13} atoms and the energymore » efficiency of atomic nitrogen production is estimated to be about 1.8 - 6.1 Multiplication-Sign 10{sup 16} atoms/J. The energy efficiency of atomic nitrogen production in N{sub 2} discharge is constant against the discharge energy, while that in N{sub 2}/O{sub 2} discharge increases with discharge energy. In the N{sub 2}/O{sub 2} discharge, two-step process of N{sub 2} dissociation plays significant role for atomic nitrogen production.« less

  1. Structural Characterization and Absolute Luminescence Efficiency Evaluation of Gd2O2S High Packing Density Ceramic Screens Doped with Tb3+ and Eu3+ for further Applications in Radiology

    NASA Astrophysics Data System (ADS)

    Dezi, Anna; Monachesi, Elenasophie; D'Ignazio, Michela; Scalise, Lorenzo; Montalto, Luigi; Paone, Nicola; Rinaldi, Daniele; Mengucci, Paolo; Loudos, George; Bakas, Athanasios; Michail, Christos; Valais, Ioannis; Fountzoula, Christine; Fountos, George; David, Stratos

    2017-11-01

    Rare earth activators are impurities added in the phosphor material to enhance probability of visible photon emission during the luminescence process. The main activators employed are rare earth trivalent ions such as Ce+3, Tb+3, Pr3+ and Eu+3. In this work, four terbium-activated Gd2O2S (GOS) powder screens with different thicknesses (1049 mg/cm2, 425.41 mg/cm2, 313 mg/cm2 and 187.36 mg/cm2) and one europium-activated GOS powder screen (232.18 mg/cm2) were studied to investigate possible applications for general radiology detectors. Results presented relevant differences in crystallinity between the GOS:Tb doped screens and GOS:Eu screens in respect to the dopant agent present. The AE (Absolute efficiency) was found to rise (i) with the increase of the X-ray tube voltage with the highest peaking at 110kVp and (ii) with the decrease of the thickness among the four GOS:Tb. Comparing similar thickness values, the europium-activated powder screen showed lower AE than the corresponding terbium-activated.

  2. A Java program for LRE-based real-time qPCR that enables large-scale absolute quantification.

    PubMed

    Rutledge, Robert G

    2011-03-02

    Linear regression of efficiency (LRE) introduced a new paradigm for real-time qPCR that enables large-scale absolute quantification by eliminating the need for standard curves. Developed through the application of sigmoidal mathematics to SYBR Green I-based assays, target quantity is derived directly from fluorescence readings within the central region of an amplification profile. However, a major challenge of implementing LRE quantification is the labor intensive nature of the analysis. Utilizing the extensive resources that are available for developing Java-based software, the LRE Analyzer was written using the NetBeans IDE, and is built on top of the modular architecture and windowing system provided by the NetBeans Platform. This fully featured desktop application determines the number of target molecules within a sample with little or no intervention by the user, in addition to providing extensive database capabilities. MS Excel is used to import data, allowing LRE quantification to be conducted with any real-time PCR instrument that provides access to the raw fluorescence readings. An extensive help set also provides an in-depth introduction to LRE, in addition to guidelines on how to implement LRE quantification. The LRE Analyzer provides the automated analysis and data storage capabilities required by large-scale qPCR projects wanting to exploit the many advantages of absolute quantification. Foremost is the universal perspective afforded by absolute quantification, which among other attributes, provides the ability to directly compare quantitative data produced by different assays and/or instruments. Furthermore, absolute quantification has important implications for gene expression profiling in that it provides the foundation for comparing transcript quantities produced by any gene with any other gene, within and between samples.

  3. Absolute photoionization cross-section of the methyl radical.

    PubMed

    Taatjes, Craig A; Osborn, David L; Selby, Talitha M; Meloni, Giovanni; Fan, Haiyan; Pratt, Stephen T

    2008-10-02

    The absolute photoionization cross-section of the methyl radical has been measured using two completely independent methods. The CH3 photoionization cross-section was determined relative to that of acetone and methyl vinyl ketone at photon energies of 10.2 and 11.0 eV by using a pulsed laser-photolysis/time-resolved synchrotron photoionization mass spectrometry method. The time-resolved depletion of the acetone or methyl vinyl ketone precursor and the production of methyl radicals following 193 nm photolysis are monitored simultaneously by using time-resolved synchrotron photoionization mass spectrometry. Comparison of the initial methyl signal with the decrease in precursor signal, in combination with previously measured absolute photoionization cross-sections of the precursors, yields the absolute photoionization cross-section of the methyl radical; sigma(CH3)(10.2 eV) = (5.7 +/- 0.9) x 10(-18) cm(2) and sigma(CH3)(11.0 eV) = (6.0 +/- 2.0) x 10(-18) cm(2). The photoionization cross-section for vinyl radical determined by photolysis of methyl vinyl ketone is in good agreement with previous measurements. The methyl radical photoionization cross-section was also independently measured relative to that of the iodine atom by comparison of ionization signals from CH3 and I fragments following 266 nm photolysis of methyl iodide in a molecular-beam ion-imaging apparatus. These measurements gave a cross-section of (5.4 +/- 2.0) x 10(-18) cm(2) at 10.460 eV, (5.5 +/- 2.0) x 10(-18) cm(2) at 10.466 eV, and (4.9 +/- 2.0) x 10(-18) cm(2) at 10.471 eV. The measurements allow relative photoionization efficiency spectra of methyl radical to be placed on an absolute scale and will facilitate quantitative measurements of methyl concentrations by photoionization mass spectrometry.

  4. A Java Program for LRE-Based Real-Time qPCR that Enables Large-Scale Absolute Quantification

    PubMed Central

    Rutledge, Robert G.

    2011-01-01

    Background Linear regression of efficiency (LRE) introduced a new paradigm for real-time qPCR that enables large-scale absolute quantification by eliminating the need for standard curves. Developed through the application of sigmoidal mathematics to SYBR Green I-based assays, target quantity is derived directly from fluorescence readings within the central region of an amplification profile. However, a major challenge of implementing LRE quantification is the labor intensive nature of the analysis. Findings Utilizing the extensive resources that are available for developing Java-based software, the LRE Analyzer was written using the NetBeans IDE, and is built on top of the modular architecture and windowing system provided by the NetBeans Platform. This fully featured desktop application determines the number of target molecules within a sample with little or no intervention by the user, in addition to providing extensive database capabilities. MS Excel is used to import data, allowing LRE quantification to be conducted with any real-time PCR instrument that provides access to the raw fluorescence readings. An extensive help set also provides an in-depth introduction to LRE, in addition to guidelines on how to implement LRE quantification. Conclusions The LRE Analyzer provides the automated analysis and data storage capabilities required by large-scale qPCR projects wanting to exploit the many advantages of absolute quantification. Foremost is the universal perspective afforded by absolute quantification, which among other attributes, provides the ability to directly compare quantitative data produced by different assays and/or instruments. Furthermore, absolute quantification has important implications for gene expression profiling in that it provides the foundation for comparing transcript quantities produced by any gene with any other gene, within and between samples. PMID:21407812

  5. High-efficiency frequency doubling of continuous-wave laser light.

    PubMed

    Ast, Stefan; Nia, Ramon Moghadas; Schönbeck, Axel; Lastzka, Nico; Steinlechner, Jessica; Eberle, Tobias; Mehmet, Moritz; Steinlechner, Sebastian; Schnabel, Roman

    2011-09-01

    We report on the observation of high-efficiency frequency doubling of 1550 nm continuous-wave laser light in a nonlinear cavity containing a periodically poled potassium titanyl phosphate crystal (PPKTP). The fundamental field had a power of 1.10 W and was converted into 1.05 W at 775 nm, yielding a total external conversion efficiency of 95±1%. The latter value is based on the measured depletion of the fundamental field being consistent with the absolute values derived from numerical simulations. According to our model, the conversion efficiency achieved was limited by the nonperfect mode matching into the nonlinear cavity and by the nonperfect impedance matching for the maximum input power available. Our result shows that cavity-assisted frequency conversion based on PPKTP is well suited for low-decoherence frequency conversion of quantum states of light.

  6. Wide-field airborne laser diode array illuminator: demonstration results

    NASA Astrophysics Data System (ADS)

    Suiter, H. R.; Holloway, J. H., Jr.; Tinsley, K. R.; Pham, C. N.; Kloess, E. C., III; Witherspoon, N. H.; Stetson, S.; Crosby, F.; Nevis, A.; McCarley, K. A.; Seales, T. C.

    2005-06-01

    The Airborne Littoral Reconnaissance Technology (ALRT) program has successfully demonstrated the Wide-Field Airborne Laser Diode Array Illuminator (ALDAI-W). This illuminator is designed to illuminate a large area from the air with limited power, weight, and volume. A detection system, of which the ALDAI-W is a central portion, is capable of detecting surface-laid minefields in absolute darkness, extending the allowed mission times to night operations. This will be an overview report, giving processing results and suggested paths for additional development.

  7. Advanced oxidation technology for H2S odor gas using non-thermal plasma

    NASA Astrophysics Data System (ADS)

    Tao, ZHU; Ruonan, WANG; Wenjing, BIAN; Yang, CHEN; Weidong, JING

    2018-05-01

    Non-thermal plasma technology is a new type of odor treatment processing. We deal with H2S from waste gas emission using non-thermal plasma generated by dielectric barrier discharge. On the basis of two criteria, removal efficiency and absolute removal amount, we deeply investigate the changes in electrical parameters and process parameters, and the reaction process of the influence of ozone on H2S gas removal. The experimental results show that H2S removal efficiency is proportional to the voltage, frequency, power, residence time and energy efficiency, while it is inversely proportional to the initial concentration of H2S gas, and ozone concentration. This study lays the foundations of non-thermal plasma technology for further commercial application.

  8. One joule output from a diode-array-pumped Nd:YAG laser with side-pumped rod geometry

    NASA Technical Reports Server (NTRS)

    Kasinski, Jeffrey J.; Hughes, Will; Dibiase, Don; Bournes, Patrick; Burnham, Ralph

    1992-01-01

    Output of 1.25 J per pulse (1.064 micron) with an absolute optical efficiency of 28 percent and corresponding electrical efficiency of 10 percent was demonstrated in a diode-array-pumped Nd:YAG laser using a side-pumped rod geometry in a master-oscillator/power-amplifier configuration. In Q-switched operation, an output of 0.75 J in a 17-ns pulse was obtained. The fundamental laser output was frequency doubled in KTP with 60 percent conversion efficiency to obtain 0.45 J in a 16-ns pulse at 532 nm. The output beam had high spatial quality with pointing stability better than 40 microrad and a shot-to-shot pulse energy fluctuation of less than +/-3 percent.

  9. High efficiency carbon nanotube thread antennas

    NASA Astrophysics Data System (ADS)

    Amram Bengio, E.; Senic, Damir; Taylor, Lauren W.; Tsentalovich, Dmitri E.; Chen, Peiyu; Holloway, Christopher L.; Babakhani, Aydin; Long, Christian J.; Novotny, David R.; Booth, James C.; Orloff, Nathan D.; Pasquali, Matteo

    2017-10-01

    Although previous research has explored the underlying theory of high-frequency behavior of carbon nanotubes (CNTs) and CNT bundles for antennas, there is a gap in the literature for direct experimental measurements of radiation efficiency. These measurements are crucial for any practical application of CNT materials in wireless communication. In this letter, we report a measurement technique to accurately characterize the radiation efficiency of λ/4 monopole antennas made from the CNT thread. We measure the highest absolute values of radiation efficiency for CNT antennas of any type, matching that of copper wire. To capture the weight savings, we propose a specific radiation efficiency metric and show that these CNT antennas exceed copper's performance by over an order of magnitude at 1 GHz and 2.4 GHz. We also report direct experimental observation that, contrary to metals, the radiation efficiency of the CNT thread improves significantly at higher frequencies. These results pave the way for practical applications of CNT thread antennas, particularly in the aerospace and wearable electronics industries where weight saving is a priority.

  10. Novel method to detect microRNAs using chip-based QuantStudio 3D digital PCR.

    PubMed

    Conte, Davide; Verri, Carla; Borzi, Cristina; Suatoni, Paola; Pastorino, Ugo; Sozzi, Gabriella; Fortunato, Orazio

    2015-10-23

    Research efforts for the management of cancer, in particular for lung cancer, are directed to identify new strategies for its early detection. MicroRNAs (miRNAs) are a new promising class of circulating biomarkers for cancer detection, but lack of consensus on data normalization methods has affected the diagnostic potential of circulating miRNAs. There is a growing interest in techniques that allow an absolute quantification of miRNAs which could be useful for early diagnosis. Recently, digital PCR, mainly based on droplets generation, emerged as an affordable technology for precise and absolute quantification of nucleic acids. In this work, we described a new interesting approach for profiling circulating miRNAs in plasma samples using a chip-based platform, the QuantStudio 3D digital PCR. The proposed method was validated using synthethic oligonucleotide at serial dilutions in plasma samples of lung cancer patients and in lung tissues and cell lines. Given its reproducibility and reliability, our approach could be potentially applied for the identification and quantification of miRNAs in other biological samples such as circulating exosomes or protein complexes. As chip-digital PCR becomes more established, it would be a robust tool for quantitative assessment of miRNA copy number for diagnosis of lung cancer and other diseases.

  11. The influence of seine capture efficiency on fish abundance estimates in the upper Mississippi River

    USGS Publications Warehouse

    Holland Bartels, L. E.; Dewey, M.R.

    1997-01-01

    The effects of season, presence of vegetation, and time of day on seine capture efficiency for fish were evaluated using test enclosures in the upper Mississippi River. Overall capture efficiency of the seine haul was 49% (53% during the day and 43% at night). During daytime tests, the efficiency ranged from 39% to 74% but did not differ statistically between sites or among dates. At night, the efficiency was higher at the vegetated than at the nonvegetated site (55% vs 32%) and declined through time from 56% in May to 28% in October. Although susceptibility to capture differed among taxa, we could not predict either total catch efficiency or efficiency within a given taxon for a given sample. Adjustment of catch data with various estimates of efficiency reduced the mean absolute error for all sampling dates from 51% to 24%, but the error of the adjusted data still ranged from -58% to +54% on any given sampling date. These results indicate that it is difficult to make accurate adjustment of catch data to compensate for gear bias in studies of seasonal habitat use.

  12. Probing Carbohydrate Product Expulsion from a Processive Cellulase with Multiple Absolute Binding Free Energy Methods*

    PubMed Central

    Bu, Lintao; Beckham, Gregg T.; Shirts, Michael R.; Nimlos, Mark R.; Adney, William S.; Himmel, Michael E.; Crowley, Michael F.

    2011-01-01

    Understanding the enzymatic mechanism that cellulases employ to degrade cellulose is critical to efforts to efficiently utilize plant biomass as a sustainable energy resource. A key component of cellulase action on cellulose is product inhibition from monosaccharide and disaccharides in the product site of cellulase tunnel. The absolute binding free energy of cellobiose and glucose to the product site of the catalytic tunnel of the Family 7 cellobiohydrolase (Cel7A) of Trichoderma reesei (Hypocrea jecorina) was calculated using two different approaches: steered molecular dynamics (SMD) simulations and alchemical free energy perturbation molecular dynamics (FEP/MD) simulations. For the SMD approach, three methods based on Jarzynski's equality were used to construct the potential of mean force from multiple pulling trajectories. The calculated binding free energies, −14.4 kcal/mol using SMD and −11.2 kcal/mol using FEP/MD, are in good qualitative agreement. Analysis of the SMD pulling trajectories suggests that several protein residues (Arg-251, Asp-259, Asp-262, Trp-376, and Tyr-381) play key roles in cellobiose and glucose binding to the catalytic tunnel. Five mutations (R251A, D259A, D262A, W376A, and Y381A) were made computationally to measure the changes in free energy during the product expulsion process. The absolute binding free energies of cellobiose to the catalytic tunnel of these five mutants are −13.1, −6.0, −11.5, −7.5, and −8.8 kcal/mol, respectively. The results demonstrated that all of the mutants tested can lower the binding free energy of cellobiose, which provides potential applications in engineering the enzyme to accelerate the product expulsion process and improve the efficiency of biomass conversion. PMID:21454590

  13. Improving Spleen Volume Estimation via Computer Assisted Segmentation on Clinically Acquired CT Scans

    PubMed Central

    Xu, Zhoubing; Gertz, Adam L.; Burke, Ryan P.; Bansal, Neil; Kang, Hakmook; Landman, Bennett A.; Abramson, Richard G.

    2016-01-01

    OBJECTIVES Multi-atlas fusion is a promising approach for computer-assisted segmentation of anatomical structures. The purpose of this study was to evaluate the accuracy and time efficiency of multi-atlas segmentation for estimating spleen volumes on clinically-acquired CT scans. MATERIALS AND METHODS Under IRB approval, we obtained 294 deidentified (HIPAA-compliant) abdominal CT scans on 78 subjects from a recent clinical trial. We compared five pipelines for obtaining splenic volumes: Pipeline 1–manual segmentation of all scans, Pipeline 2–automated segmentation of all scans, Pipeline 3–automated segmentation of all scans with manual segmentation for outliers on a rudimentary visual quality check, Pipelines 4 and 5–volumes derived from a unidimensional measurement of craniocaudal spleen length and three-dimensional splenic index measurements, respectively. Using Pipeline 1 results as ground truth, the accuracy of Pipelines 2–5 (Dice similarity coefficient [DSC], Pearson correlation, R-squared, and percent and absolute deviation of volume from ground truth) were compared for point estimates of splenic volume and for change in splenic volume over time. Time cost was also compared for Pipelines 1–5. RESULTS Pipeline 3 was dominant in terms of both accuracy and time cost. With a Pearson correlation coefficient of 0.99, average absolute volume deviation 23.7 cm3, and 1 minute per scan, Pipeline 3 yielded the best results. The second-best approach was Pipeline 5, with a Pearson correlation coefficient 0.98, absolute deviation 46.92 cm3, and 1 minute 30 seconds per scan. Manual segmentation (Pipeline 1) required 11 minutes per scan. CONCLUSION A computer-automated segmentation approach with manual correction of outliers generated accurate splenic volumes with reasonable time efficiency. PMID:27519156

  14. Lymphocyte apheresis for chimeric antigen receptor T-cell manufacturing in children and young adults with leukemia and neuroblastoma.

    PubMed

    Ceppi, Francesco; Rivers, Julie; Annesley, Colleen; Pinto, Navin; Park, Julie R; Lindgren, Catherine; Mgebroff, Stephanie; Linn, Naomi; Delaney, Meghan; Gardner, Rebecca A

    2018-06-01

    The first step in the production of chimeric antigen receptor T cells is the collection of autologous T cells using apheresis technology. The procedure is technically challenging, because patients often have low leukocyte counts and are heavily pretreated with multiple lines of chemotherapy, marrow transplantation, and/or radiotherapy. Here, we report our experience of collecting T lymphocytes for chimeric antigen receptor T-cell manufacturing in pediatric and young adult patients with leukemia, non-Hodgkin lymphoma, or neuroblastoma. Apheresis procedures were performed on a COBE Spectra machine using the mononuclear cell program, with a collection target of 1 × 10 9 total mononuclear cells per kilogram. Data were collected regarding preapheresis and postapheresis blood counts, apheresis parameters, products, and adverse events. Ninety-nine patients (ages 1.3-25.7 years) and 102 apheresis events were available for analysis. Patients underwent apheresis at a variety of absolute lymphocyte cell counts, with a median absolute lymphocyte count of 944 cells/μL (range, 142-6944 cells/μL). Twenty-two patients (21.6%) had absolute lymphocyte counts less than 500 cells/μL. The mononuclear cell target was obtained in 100% of all apheresis harvests, and chimeric antigen receptor T-cell production was possible from the majority of collections (94%). Mononuclear cell collection efficiency was 65.4%, and T-lymphocyte collection efficiency was 83.4%. Ten patients (9.8%) presented with minor adverse events during the 102 apheresis procedures, with one exception of a severe allergy. Mononuclear cell apheresis for chimeric antigen receptor T-cell therapy is well tolerated and safe, and it is possible to obtain an adequate quantity of CD3+ lymphocytes for chimeric antigen receptor T-cell manufacturing in heavily pretreated patients who have low lymphocyte counts. © 2018 AABB.

  15. First light measurements of the Total Solar Irradiance experiment CLARA on NORSAT-1

    NASA Astrophysics Data System (ADS)

    Schmutz, Werner

    2016-07-01

    NORSAT-1 is a Norwegian micro-satellite, which will be launched April 22, 2016. (In the future at the time of writing this abstract.) The satellite carries two scientific instruments and an AIS receiver for performing ship detection from space. One of the scientific instruments is a Compact Light-weight Absolute RAdiometer (CLARA) and the other is a Langmuir Probe instrument comprising four probes mounted on booms. The latter experiment will measure electron density and the platform's floating potential along the orbit. The University of Oslo provides the Langmuir probes. The radiometer experiment CLARA has been built by PMOD/WRC funded through the Swiss PRODEX program. It will measure Total Solar Irradiance with an instrument of novel design that is optimized for minimizing mass and size by still ensuring highest measuring accuracy and thermal stability. The radiometers of CLARA have been fully characterized as well as calibrated at the TRF facility. It is expected that the first light accuracy of the absolute measurement of Total Solar Irradiance will be better than pm0.3 W/m^{2, allowing to probe the current TSI composite for its absolute level. The presentation will give an overview of the CLARA instrument and its calibration. It is expected that at the time of the COSPAR conference the first light TSI value of CLARA/NORSAT-1 is ready for publication. Together with a previous absolute TSI measurements available for July 27, 2010 measured by PREMOS/PICARD the new absolute TSI measurement will be used to test the accuracy of long term TSI trend given by the relative TSI composite.

  16. Parkinson Disease Detection from Speech Articulation Neuromechanics.

    PubMed

    Gómez-Vilda, Pedro; Mekyska, Jiri; Ferrández, José M; Palacios-Alonso, Daniel; Gómez-Rodellar, Andrés; Rodellar-Biarge, Victoria; Galaz, Zoltan; Smekal, Zdenek; Eliasova, Ilona; Kostalova, Milena; Rektorova, Irena

    2017-01-01

    Aim: The research described is intended to give a description of articulation dynamics as a correlate of the kinematic behavior of the jaw-tongue biomechanical system, encoded as a probability distribution of an absolute joint velocity. This distribution may be used in detecting and grading speech from patients affected by neurodegenerative illnesses, as Parkinson Disease. Hypothesis: The work hypothesis is that the probability density function of the absolute joint velocity includes information on the stability of phonation when applied to sustained vowels, as well as on fluency if applied to connected speech. Methods: A dataset of sustained vowels recorded from Parkinson Disease patients is contrasted with similar recordings from normative subjects. The probability distribution of the absolute kinematic velocity of the jaw-tongue system is extracted from each utterance. A Random Least Squares Feed-Forward Network (RLSFN) has been used as a binary classifier working on the pathological and normative datasets in a leave-one-out strategy. Monte Carlo simulations have been conducted to estimate the influence of the stochastic nature of the classifier. Two datasets for each gender were tested (males and females) including 26 normative and 53 pathological subjects in the male set, and 25 normative and 38 pathological in the female set. Results: Male and female data subsets were tested in single runs, yielding equal error rates under 0.6% (Accuracy over 99.4%). Due to the stochastic nature of each experiment, Monte Carlo runs were conducted to test the reliability of the methodology. The average detection results after 200 Montecarlo runs of a 200 hyperplane hidden layer RLSFN are given in terms of Sensitivity (males: 0.9946, females: 0.9942), Specificity (males: 0.9944, females: 0.9941) and Accuracy (males: 0.9945, females: 0.9942). The area under the ROC curve is 0.9947 (males) and 0.9945 (females). The equal error rate is 0.0054 (males) and 0.0057 (females). Conclusions: The proposed methodology avails that the use of highly normalized descriptors as the probability distribution of kinematic variables of vowel articulation stability, which has some interesting properties in terms of information theory, boosts the potential of simple yet powerful classifiers in producing quite acceptable detection results in Parkinson Disease.

  17. Detecting and quantifying stellar magnetic fields. Sparse Stokes profile approximation using orthogonal matching pursuit

    NASA Astrophysics Data System (ADS)

    Carroll, T. A.; Strassmeier, K. G.

    2014-03-01

    Context. In recent years, we have seen a rapidly growing number of stellar magnetic field detections for various types of stars. Many of these magnetic fields are estimated from spectropolarimetric observations (Stokes V) by using the so-called center-of-gravity (COG) method. Unfortunately, the accuracy of this method rapidly deteriorates with increasing noise and thus calls for a more robust procedure that combines signal detection and field estimation. Aims: We introduce an estimation method that provides not only the effective or mean longitudinal magnetic field from an observed Stokes V profile but also uses the net absolute polarization of the profile to obtain an estimate of the apparent (i.e., velocity resolved) absolute longitudinal magnetic field. Methods: By combining the COG method with an orthogonal-matching-pursuit (OMP) approach, we were able to decompose observed Stokes profiles with an overcomplete dictionary of wavelet-basis functions to reliably reconstruct the observed Stokes profiles in the presence of noise. The elementary wave functions of the sparse reconstruction process were utilized to estimate the effective longitudinal magnetic field and the apparent absolute longitudinal magnetic field. A multiresolution analysis complements the OMP algorithm to provide a robust detection and estimation method. Results: An extensive Monte-Carlo simulation confirms the reliability and accuracy of the magnetic OMP approach where a mean error of under 2% is found. Its full potential is obtained for heavily noise-corrupted Stokes profiles with signal-to-noise variance ratios down to unity. In this case a conventional COG method yields a mean error for the effective longitudinal magnetic field of up to 50%, whereas the OMP method gives a maximum error of 18%. It is, moreover, shown that even in the case of very small residual noise on a level between 10-3 and 10-5, a regime reached by current multiline reconstruction techniques, the conventional COG method incorrectly interprets a large portion of the residual noise as a magnetic field, with values of up to 100 G. The magnetic OMP method, on the other hand, remains largely unaffected by the noise, regardless of the noise level the maximum error is no greater than 0.7 G.

  18. A generalised random encounter model for estimating animal density with remote sensor data.

    PubMed

    Lucas, Tim C D; Moorcroft, Elizabeth A; Freeman, Robin; Rowcliffe, J Marcus; Jones, Kate E

    2015-05-01

    Wildlife monitoring technology is advancing rapidly and the use of remote sensors such as camera traps and acoustic detectors is becoming common in both the terrestrial and marine environments. Current methods to estimate abundance or density require individual recognition of animals or knowing the distance of the animal from the sensor, which is often difficult. A method without these requirements, the random encounter model (REM), has been successfully applied to estimate animal densities from count data generated from camera traps. However, count data from acoustic detectors do not fit the assumptions of the REM due to the directionality of animal signals.We developed a generalised REM (gREM), to estimate absolute animal density from count data from both camera traps and acoustic detectors. We derived the gREM for different combinations of sensor detection widths and animal signal widths (a measure of directionality). We tested the accuracy and precision of this model using simulations of different combinations of sensor detection widths and animal signal widths, number of captures and models of animal movement.We find that the gREM produces accurate estimates of absolute animal density for all combinations of sensor detection widths and animal signal widths. However, larger sensor detection and animal signal widths were found to be more precise. While the model is accurate for all capture efforts tested, the precision of the estimate increases with the number of captures. We found no effect of different animal movement models on the accuracy and precision of the gREM.We conclude that the gREM provides an effective method to estimate absolute animal densities from remote sensor count data over a range of sensor and animal signal widths. The gREM is applicable for count data obtained in both marine and terrestrial environments, visually or acoustically (e.g. big cats, sharks, birds, echolocating bats and cetaceans). As sensors such as camera traps and acoustic detectors become more ubiquitous, the gREM will be increasingly useful for monitoring unmarked animal populations across broad spatial, temporal and taxonomic scales.

  19. The Geostationary Lightning Mapper: Its Performance and Calibration

    NASA Astrophysics Data System (ADS)

    Christian, H. J., Jr.

    2015-12-01

    The Geostationary Lightning Mapper (GLM) has been developed to be an operational instrument on the GOES-R series of spacecraft. The GLM is a unique instrument, unlike other meteorological instruments, both in how it operates and in the information content that it provides. Instrumentally, it is an event detector, rather than an imager. While processing almost a billion pixels per second with 14 bits of resolution, the event detection process reduces the required telemetry bandwidth by almost 105, thus keeping the telemetry requirements modest and enabling efficient ground processing that leads to rapid data distribution to operational users. The GLM was designed to detect about 90 percent of the total lightning flashes within its almost hemispherical field of view. Based on laboratory calibration, we expect the on-orbit detection efficiency to be closer to 85%, making it the highest performing, large area coverage total lightning detector. It has a number of unique design features that will enable it have near uniform special resolution over most of its field of view and to operate with minimal impact on performance during solar eclipses. The GLM has no dedicated on-orbit calibration system, thus the ground-based calibration provides the bases for the predicted radiometric performance. A number of problems were encountered during the calibration of Flight Model 1. The issues arouse from GLM design features including its wide field of view, fast lens, the narrow-band interference filters located in both object and collimated space and the fact that the GLM is inherently a event detector yet the calibration procedures required both calibration of images and events. The GLM calibration techniques were based on those developed for the Lightning Imaging Sensor calibration, but there are enough differences between the sensors that the initial GLM calibration suggested that it is significantly more sensitive than its design parameters. The calibration discrepancies have been resolved and will be discussed. Absolute calibration will be verified on-orbit using vicarious cloud reflections. In addition to details of the GLM calibration, the presentation will address the unique design of the GLM, its features, capabilities and performance.

  20. Evaluating Humidity Recovery Efficiency of Currently Available Heat and Moisture Exchangers: A Respiratory System Model Study

    PubMed Central

    Lucato, Jeanette Janaina Jaber; Adams, Alexander Bernard; Souza, Rogério; Torquato, Jamili Anbar; Carvalho, Carlos Roberto Ribeiro; Marini, John J

    2009-01-01

    OBJECTIVES: To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. INTRODUCTION: Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute humidity of air retrieved from and returned to the ventilated patient is an important measurable outcome of the heat and moisture exchangers’ humidifying performance. METHODS: Eight different heat and moisture exchangers were studied using a respiratory system analog. The system included a heated chamber (acrylic glass, maintained at 37°C), a preserved swine lung, a hygrometer, circuitry and a ventilator. Humidity and temperature levels were measured using eight distinct interposed heat and moisture exchangers given different tidal volumes, respiratory frequencies and flow-rate conditions. Recovery of absolute humidity (%RAH) was calculated for each setting. RESULTS: Increasing tidal volumes led to a reduction in %RAH for all heat and moisture exchangers while no significant effect was demonstrated in the context of varying respiratory rate or inspiratory flow. CONCLUSIONS: Our data indicate that heat and moisture exchangers are more efficient when used with low tidal volume ventilation. The roles of flow and respiratory rate were of lesser importance, suggesting that their adjustment has a less significant effect on the performance of heat and moisture exchangers. PMID:19578664

  1. The Nature of Infant Color Categorization: Evidence from Eye Movements on a Target Detection Task

    ERIC Educational Resources Information Center

    Franklin, A.; Pilling, M.; Davies, I.

    2005-01-01

    Infants respond categorically to color. However, the nature of infants' categorical responding to color is unclear. The current study investigated two issues. First, is infants' categorical responding more absolute than adults' categorical responding? That is, can infants discriminate two stimuli from the same color category? Second, is color…

  2. Sampling methods to detect and estimate populations of Tyrophagus putrescentiae (Schrank) (Sarcoptiformes: Acaridae) infesting dry-cured hams

    USDA-ARS?s Scientific Manuscript database

    Spatial and temporal dynamics of pest populations is an important aspect of effective pest management. However, absolute sampling of some pest populations such as the ham mite, Tyrophagus putrescentiae (Schrank) (Sarcoptiformes: Acaridae), a serious pest of dry-cured ham, can be difficult. Sampling ...

  3. 40 CFR 63.11224 - What are my monitoring, installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... include a daily calibration drift assessment, a quarterly performance audit, and an annual zero alignment... performance audit, or an annual zero alignment audit. (7) You must calculate and record 6-minute averages from... absolute particulate matter loadings. (5) The bag leak detection system must be equipped with a device to...

  4. 40 CFR 63.11224 - What are my monitoring, installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... include a daily calibration drift assessment, a quarterly performance audit, and an annual zero alignment... performance audit, or an annual zero alignment audit. (7) You must calculate and record 6-minute averages from... absolute particulate matter loadings. (5) The bag leak detection system must be equipped with a device to...

  5. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Applications in Quantitative Proteomics.

    PubMed

    Chahrour, Osama; Malone, John

    2017-01-01

    Recent advances in inductively coupled plasma mass spectrometry (ICP-MS) hyphenated to different separation techniques have promoted it as a valuable tool in protein/peptide quantification. These emerging ICP-MS applications allow absolute quantification by measuring specific elemental responses. One approach quantifies elements already present in the structure of the target peptide (e.g. phosphorus and sulphur) as natural tags. Quantification of these natural tags allows the elucidation of the degree of protein phosphorylation in addition to absolute protein quantification. A separate approach is based on utilising bi-functional labelling substances (those containing ICP-MS detectable elements), that form a covalent chemical bond with the protein thus creating analogs which are detectable by ICP-MS. Based on the previously established stoichiometries of the labelling reagents, quantification can be achieved. This technique is very useful for the design of precise multiplexed quantitation schemes to address the challenges of biomarker screening and discovery. This review discusses the capabilities and different strategies to implement ICP-MS in the field of quantitative proteomics. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Time-resolved photoion imaging spectroscopy: Determining energy distribution in multiphoton absorption experiments

    NASA Astrophysics Data System (ADS)

    Qian, D. B.; Shi, F. D.; Chen, L.; Martin, S.; Bernard, J.; Yang, J.; Zhang, S. F.; Chen, Z. Q.; Zhu, X. L.; Ma, X.

    2018-04-01

    We propose an approach to determine the excitation energy distribution due to multiphoton absorption in the case of excited systems following decays to produce different ion species. This approach is based on the measurement of the time-resolved photoion position spectrum by using velocity map imaging spectrometry and an unfocused laser beam with a low fluence and homogeneous profile. Such a measurement allows us to identify the species and the origin of each ion detected and to depict the energy distribution using a pure Poisson's equation involving only one variable which is proportional to the absolute photon absorption cross section. A cascade decay model is used to build direct connections between the energy distribution and the probability to detect each ionic species. Comparison between experiments and simulations permits the energy distribution and accordingly the absolute photon absorption cross section to be determined. This approach is illustrated using C60 as an example. It may therefore be extended to a wide variety of molecules and clusters having decay mechanisms similar to those of fullerene molecules.

  7. Quantitative Phase Fraction Detection in Organic Photovoltaic Materials through EELS Imaging

    DOE PAGES

    Dyck, Ondrej; Hu, Sheng; Das, Sanjib; ...

    2015-11-24

    Organic photovoltaic materials have recently seen intense interest from the research community. Improvements in device performance are occurring at an impressive rate; however, visualization of the active layer phase separation still remains a challenge. Our paper outlines the application of two electron energy-loss spectroscopic (EELS) imaging techniques that can complement and enhance current phase detection techniques. Specifically, the bulk plasmon peak position, often used to produce contrast between phases in energy filtered transmission electron microscopy (EFTEM), is quantitatively mapped across a sample cross section. One complementary spectrum image capturing the carbon and sulfur core loss edges is compared with themore » plasmon peak map and found to agree quite well, indicating that carbon and sulfur density differences between the two phases also allows phase discrimination. Additionally, an analytical technique for determining absolute atomic areal density is used to produce an absolute carbon and sulfur areal density map. We also show how these maps may be re-interpreted as a phase ratio map, giving quantitative information about the purity of the phases within the junction.« less

  8. Laser-based absorption spectroscopy as a technique for rapid in-line analysis of respired gas concentrations of O2 and CO2

    PubMed Central

    Cummings, Beth; Hamilton, Michelle L.; Ciaffoni, Luca; Pragnell, Timothy R.; Peverall, Rob; Ritchie, Grant A. D.; Hancock, Gus

    2011-01-01

    The use of sidestream analyzers for respired gas analysis is almost universal. However, they are not ideal for measurements of respiratory gas exchange because the analyses are both temporally dissociated from measurements of respiratory flow and also not generally conducted under the same physical conditions. This study explores the possibility of constructing an all optical, fast response, in-line breath analyzer for oxygen and carbon dioxide. Using direct absorption spectroscopy with a diode laser operating at a wavelength near 2 μm, measurements of expired carbon dioxide concentrations were obtained with an absolute limit of detection of 0.04% at a time resolution of 10 ms. Simultaneously, cavity enhanced absorption spectroscopy at a wavelength near 760 nm was employed to obtain measurements of expired oxygen concentrations with an absolute limit of detection of 0.26% at a time resolution of 10 ms. We conclude that laser-based absorption spectroscopy is a promising technology for in-line analysis of respired carbon dioxide and oxygen concentrations. PMID:21512147

  9. Laser-based absorption spectroscopy as a technique for rapid in-line analysis of respired gas concentrations of O2 and CO2.

    PubMed

    Cummings, Beth; Hamilton, Michelle L; Ciaffoni, Luca; Pragnell, Timothy R; Peverall, Rob; Ritchie, Grant A D; Hancock, Gus; Robbins, Peter A

    2011-07-01

    The use of sidestream analyzers for respired gas analysis is almost universal. However, they are not ideal for measurements of respiratory gas exchange because the analyses are both temporally dissociated from measurements of respiratory flow and also not generally conducted under the same physical conditions. This study explores the possibility of constructing an all optical, fast response, in-line breath analyzer for oxygen and carbon dioxide. Using direct absorption spectroscopy with a diode laser operating at a wavelength near 2 μm, measurements of expired carbon dioxide concentrations were obtained with an absolute limit of detection of 0.04% at a time resolution of 10 ms. Simultaneously, cavity enhanced absorption spectroscopy at a wavelength near 760 nm was employed to obtain measurements of expired oxygen concentrations with an absolute limit of detection of 0.26% at a time resolution of 10 ms. We conclude that laser-based absorption spectroscopy is a promising technology for in-line analysis of respired carbon dioxide and oxygen concentrations.

  10. Optical designs for improved solar cell performance

    NASA Astrophysics Data System (ADS)

    Kosten, Emily Dell

    The solar resource is the most abundant renewable resource on earth, yet it is currently exploited with relatively low efficiencies. To make solar energy more affordable, we can either reduce the cost of the cell or increase the efficiency with a similar cost cell. In this thesis, we consider several different optical approaches to achieve these goals. First, we consider a ray optical model for light trapping in silicon microwires. With this approach, much less material can be used, allowing for a cost savings. We next focus on reducing the escape of radiatively emitted and scattered light from the solar cell. With this angle restriction approach, light can only enter and escape the cell near normal incidence, allowing for thinner cells and higher efficiencies. In Auger-limited GaAs, we find that efficiencies greater than 38% may be achievable, a significant improvement over the current world record. To experimentally validate these results, we use a Bragg stack to restrict the angles of emitted light. Our measurements show an increase in voltage and a decrease in dark current, as less radiatively emitted light escapes. While the results in GaAs are interesting as a proof of concept, GaAs solar cells are not currently made on the production scale for terrestrial photovoltaic applications. We therefore explore the application of angle restriction to silicon solar cells. While our calculations show that Auger-limited cells give efficiency increases of up to 3% absolute, we also find that current amorphous silicion-crystalline silicon heterojunction with intrinsic thin layer (HIT) cells give significant efficiency gains with angle restriction of up to 1% absolute. Thus, angle restriction has the potential for unprecedented one sun efficiencies in GaAs, but also may be applicable to current silicon solar cell technology. Finally, we consider spectrum splitting, where optics direct light in different wavelength bands to solar cells with band gaps tuned to those wavelengths. This approach has the potential for very high efficiencies, and excellent annual power production. Using a light-trapping filtered concentrator approach, we design filter elements and find an optimal design. Thus, this thesis explores silicon microwires, angle restriction, and spectral splitting as different optical approaches for improving the cost and efficiency of solar cells.

  11. Method and apparatus for making absolute range measurements

    DOEpatents

    Earl, Dennis D [Knoxville, TN; Allison, Stephen W [Knoxville, TN; Cates, Michael R [Oak Ridge, TN; Sanders, Alvin J [Knoxville, TN

    2002-09-24

    This invention relates to a method and apparatus for making absolute distance or ranging measurements using Fresnel diffraction. The invention employs a source of electromagnetic radiation having a known wavelength or wavelength distribution, which sends a beam of electromagnetic radiation through a screen at least partially opaque at the wavelength. The screen has an aperture sized so as to produce a Fresnel diffraction pattern. A portion of the beam travels through the aperture to a detector spaced some distance from the screen. The detector detects the central intensity of the beam as well as a set of intensities displaced from a center of the aperture. The distance from the source to the target can then be calculated based upon the known wavelength, aperture radius, and beam intensity.

  12. Pharmacokinetics of tramadol and its major metabolites following rectal and intravenous administration in dogs.

    PubMed

    Giorgi, M; Del Carlo, S; Saccomanni, G; Łebkowska-Wieruszewska, B; Kowalski, C J

    2009-06-01

    To compare the rectal and I/V administration of tramadol in dogs, to assess both its pharmacokinetic properties and absolute bioavailability. After rectal administration via suppositories and I/V injection of tramadol (4 mg/kg), the concentration of tramadol and its main metabolites, O-desmethyl-tramadol (M1), N-desmethyl-tramadol (M2) and N,O-didesmethyl-tramadol (M5), were determined in plasma, using high-performance liquid chromatography (HPLC). A balanced cross-over study was used, involving six male Beagle dogs. Plasma concentrations after rectal and I/V administration were fitted on the basis of mono- and bi-compartmental models, respectively. Following rectal administration tramadol was detected from 5 minutes up to 10 hours, in lesser amounts than M5 and M2, while M1 was detected in negligible amounts. Following I/V administration tramadol was detected up to 10 hours, M2 and M5 were detected at similar concentrations, and M1 was present at low concentrations. The area under the curve (AUC) of the three metabolites did not differ significantly after either route of administration of tramadol. The absolute bioavailability of tramadol via rectal administration was 10 (SD 4)%. After rectal administration of tramadol suppositories, absorption of the active ingredient was rapid, but its metabolism quickly transformed the parent drug to high levels of M2 and M5. In the dog, rectal pharmaceutical formulation of tramadol would have a different pharmacokinetic behaviour than in humans.

  13. Detection of protein modifications and counterfeit protein pharmaceuticals using isotope tags for relative and absolute quantification and matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry: studies of insulins.

    PubMed

    Ye, Hongping; Hill, John; Kauffman, John; Gryniewicz, Connie; Han, Xianlin

    2008-08-15

    Isotope tags for relative and absolute quantification (iTRAQ) reagent coupled with matrix-assisted laser desorption/ionization tandem time-of-flight (MALDI-TOF/TOF) mass spectrometric analysis has been evaluated as both a qualitative and quantitative method for the detection of modifications to active pharmaceutical ingredients derived from recombinant DNA technologies and as a method to detect counterfeit drug products. Five types of insulin (human, bovine, porcine, Lispro, and Lantus) were used as model products in the study because of their minor variations in amino acid sequence. Several experiments were conducted in which each insulin variant was separately digested with Glu-C, and the digestate was labeled with one of four different iTRAQ reagents. All digestates were then combined for desalting and MALDI-TOF/TOF mass spectrometric analysis. When the digestion procedure was optimized, the insulin sequence coverage was 100%. Five different types of insulin were readily differentiated, including human insulin (P28K29) and Lispro insulin (K28P29), which differ only by the interchange of two contiguous residues. Moreover, quantitative analyses show that the results obtained from the iTRAQ method agree well with those determined by other conventional methods. Collectively, the iTRAQ method can be used as a qualitative and quantitative technique for the detection of protein modification and counterfeiting.

  14. Absolute measurements of the triplet-triplet annihilation rate and the charge-carrier recombination layer thickness in working polymer light-emitting diodes based on polyspirobifluorene

    NASA Astrophysics Data System (ADS)

    Rothe, C.; Al Attar, H. A.; Monkman, A. P.

    2005-10-01

    The triplet exciton densities in electroluminescent devices prepared from two polyspirobifluorene derivatives have been investigated by means of time-resolved transient triplet absorption as a function of optical and electrical excitation power at 20 K. Because of the low mobility of the triplet excitons at this temperature, the triplet generation profile within the active polymer layer is preserved throughout the triplet lifetime and as a consequence the absolute triplet-triplet annihilation efficiency is not homogeneously distributed but depends on position within the active layer. This then gives a method to measure the charge-carrier recombination layer after electrical excitation relative to the light penetration depth, which is identical to the triplet generation layer after optical excitation. With the latter being obtained from ellipsometry, an absolute value of 5 nm is found for the exciton formation layer in polyspirobifluorene devices. This layer increases to 11 nm if the balance between the electron and the hole mobility is improved by chemically modifying the polymer backbone. Also, and consistent with previous work, triplet diffusion is dispersive at low temperature. As a consequence of this, the triplet-triplet annihilation rate is not a constant in the classical sense but depends on the triplet excitation dose. At 20 K and for typical excitation doses, absolute values of the latter rate are of the order of 10-14cm3s-1 .

  15. A suggestion for computing objective function in model calibration

    USGS Publications Warehouse

    Wu, Yiping; Liu, Shuguang

    2014-01-01

    A parameter-optimization process (model calibration) is usually required for numerical model applications, which involves the use of an objective function to determine the model cost (model-data errors). The sum of square errors (SSR) has been widely adopted as the objective function in various optimization procedures. However, ‘square error’ calculation was found to be more sensitive to extreme or high values. Thus, we proposed that the sum of absolute errors (SAR) may be a better option than SSR for model calibration. To test this hypothesis, we used two case studies—a hydrological model calibration and a biogeochemical model calibration—to investigate the behavior of a group of potential objective functions: SSR, SAR, sum of squared relative deviation (SSRD), and sum of absolute relative deviation (SARD). Mathematical evaluation of model performance demonstrates that ‘absolute error’ (SAR and SARD) are superior to ‘square error’ (SSR and SSRD) in calculating objective function for model calibration, and SAR behaved the best (with the least error and highest efficiency). This study suggests that SSR might be overly used in real applications, and SAR may be a reasonable choice in common optimization implementations without emphasizing either high or low values (e.g., modeling for supporting resources management).

  16. Poster — Thur Eve — 72: Clinical Subtleties of Flattening-Filter-Free Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corns, Robert; Thomas, Steven; Huang, Vicky

    2014-08-15

    Flattening-filter-free (fff) beams offer superior dose rates, reducing treatment times for important techniques that utilize small field sizes, such as stereotactic ablative radiotherapy (SABR). The impact of ion collection efficiency (P{sub ion}) on the percent depth dose (PDD) has been discussed at length in the literature. Relative corrections of the order of l%–2% are possible. In the process of commissioning 6fff and 10fff beams, we identified a number of other important details that influence commissioning. We looked at the absolute dose difference between corrected and uncorrected PDD. We discovered a curve with a broad maximum between 10 and 20 cm.more » We wondered about the consequences of this PDD correction on the absolute dose calibration of the linac because the TG-51 protocol does not correct the PDD curve. The quality factor k{sub Q} depends on the PDD, so in principle, a correction to the PDD will alter the absolute calibration of the linac. Finally, there are other clinical tables, such as TMR, which are derived from PDD. Attention to details on how this computation is performed is important because different corrections are possible depending the method of calculation.« less

  17. Multichannel Nephelometer.

    DTIC Science & Technology

    1986-10-01

    consists of two near-hemispheric shells bolted to a mounted plate housing the sampling system. Its walls are anodized black to decrease 13 surface...a distinct advantage when the test aerosol contains a significant quantity of liquid. Membrane filters tend to load and reduce throughout while...Table 6. As indicated, these filters can be estremely efficient. Should absolute retention be required, the AAO grade filter with a pore size of 0.3

  18. Praseodymium methanesulfonate catalyzed one-pot synthesis of 3,4-dihydropyrimidin-2-(1H)-ones.

    PubMed

    Wang, Min; Song, Zhiguo; Gong, Hong; Jiang, Heng

    2008-01-01

    A series of 3,4-dihydropyrimidin-2-(1H)-ones compounds was synthesized efficiently by a one-pot cyclocondensation of an aldehyde, 1,3-dicarbonyl compound, and urea in absolute ethanol under refluxing temperature using praseodymium methanesulfonate as catalyst. After the reaction, the catalyst can be easily recovered and reused several times without distinct decrease in reaction yields.

  19. Conclusion (The Mobile Future)

    NASA Astrophysics Data System (ADS)

    Marcus, Aaron; Sala, Riccardo; Roibás, Anxo Cereijo

    There are a couple of fundamental beliefs that I hold about the future of technology and media. First, I believe that, absolutely, most, if not all, media will be delivered, at least intermittently in its lifecycle, over an IP network. It is an efficient carrier, it is scalable, and it can be organically evolved. Whether this is IPV6 or some other technology is inconsequential, it will just work.

  20. The electronic, 'paperless' medical office; has it arrived?

    PubMed

    Gates, P; Urquhart, J

    2007-02-01

    Modern information technology offers efficiencies in medical practice, with a reduction in secretarial time in maintaining, filing and retrieving the paper medical record. Electronic requesting of investigations allows tracking of outstanding results. Less storage space is required and telephone calls from pharmacies, pathology and medical imaging service providers to clarify the hand-written request are abolished. Voice recognition software reduces secretarial typing time per letter. These combined benefits can lead to significantly reduced costs and improved patient care. The paperless office is possible, but requires commitment and training of all staff; it is preferable but not absolutely essential that at least one member of the practice has an interest and some expertise in computers. More importantly, back-up from information technology providers and back-up of the electronic data are absolutely crucial and a paperless environment should not be considered without them.

  1. SPF32629A and SPF32629B: enantioselective synthesis, determination of absolute configuration, cytotoxicity and antibacterial evaluation.

    PubMed

    Vegi, Srinivasa Rao; Boovanahalli, Shanthaveerappa K; Patro, Balaram; Mukkanti, K

    2011-05-01

    We report herein an efficient enantioselective synthesis of SPF32629A and SPF32629B through one-pot enantioselective reduction and protecting-group-free regioselective O-acylation strategy. The absolute configuration of the enantiomerically pure isomers was established by Mosher ester analysis. The inhibitory potencies of the synthesized compounds were assayed in vitro against a panel of microorganisms and against A549 human lung adenocarcinoma cell line. Compounds 2, 11 and 12 displayed moderate to potent antibacterial activity against all the tested strains and compounds 7, 8, 2, 11 and 12 exhibited significant cytotoxicity in a dose-dependent manner with an IC50 values ranging from 2.92 to 4.14 μg/ml and 8-11 μM. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  2. Measurement of the Am 242 m neutron-induced reaction cross sections

    DOE PAGES

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; ...

    2017-02-17

    The neutron-induced reaction cross sections of 242mAm were measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. A new neutron-capture cross section was determined, and the absolute scale was set according to a concurrent measurement of the well-known 242mAm(n,f) cross section. The (n,γ) cross section was measured from thermal energy to an incident energy of 1 eV at which point the data quality was limited by the reaction yield in the laboratory. Our new 242mAm fission cross section was normalized to ENDF/B-VII.1 tomore » set the absolute scale, and it agreed well with the (n,f) cross section from thermal energy to 1 keV. Lastly, the average absolute capture-to-fission ratio was determined from thermal energy to E n = 0.1 eV, and it was found to be 26(4)% as opposed to the ratio of 19% from the ENDF/B-VII.1 evaluation.« less

  3. Central-to-axial chirality transfer revealed by liquid crystals: a combined experimental and computational approach for the determination of absolute configuration of carboxylic acids with an α chirality centre.

    PubMed

    Ferrarini, Alberta; Ferroni, Fiammetta; Pieraccini, Silvia; Rosini, Carlo; Superchi, Stefano; Spada, Gian Piero

    2011-10-01

    The conversion into 6,7-dihydro-5H-dibenz[c,e]azepine (DAZ) N-protected amides is a viable route for the determination of the absolute configuration of chiral 2-substituted carboxylic acids. The biphenyl moiety of DAZ, besides being a probe of chirality for the electronic circular dichroism (ECD) spectroscopy, makes these systems suitable for configuration assignment by exploiting the chirality amplification which occurs in nematic liquid crystals. To assess the reliability of the liquid crystal method in detecting the absolute stereochemistry of chiral amides bound to a biphenyl group, we measured the helical twisting power of a series of DAZ-N-protected amides and compared these data with the results obtained from ECD measurements. We will show that the liquid crystal method, corroborated by HTP predictions, is trustworthy with our biphenyl derivatives, even when ECD spectra are ambiguous for the presence of aryl moieties displaying strong UV absorptions in the same range of the biphenyl chromophore. © 2011 Wiley-Liss, Inc.

  4. Investigation of absolute and relative response for three different liquid chromatography/tandem mass spectrometry systems; the impact of ionization and detection saturation.

    PubMed

    Nilsson, Lars B; Skansen, Patrik

    2012-06-30

    The investigations in this article were triggered by two observations in the laboratory; for some liquid chromatography/tandem mass spectrometry (LC/MS/MS) systems it was possible to obtain linear calibration curves for extreme concentration ranges and for some systems seemingly linear calibration curves gave good accuracy at low concentrations only when using a quadratic regression function. The absolute and relative responses were tested for three different LC/MS/MS systems by injecting solutions of a model compound and a stable isotope labeled internal standard. The analyte concentration range for the solutions was 0.00391 to 500 μM (128,000×), giving overload of the chromatographic column at the highest concentrations. The stable isotope labeled internal standard concentration was 0.667 μM in all samples. The absolute response per concentration unit decreased rapidly as higher concentrations were injected. The relative response, the ratio for the analyte peak area to the internal standard peak area, per concentration unit was calculated. For system 1, the ionization process was found to limit the response and the relative response per concentration unit was constant. For systems 2 and 3, the ion detection process was the limiting factor resulting in decreasing relative response at increasing concentrations. For systems behaving like system 1, simple linear regression can be used for any concentration range while, for systems behaving like systems 2 and 3, non-linear regression is recommended for all concentration ranges. Another consequence is that the ionization capacity limited systems will be insensitive to matrix ion suppression when an ideal internal standard is used while the detection capacity limited systems are at risk of giving erroneous results at high concentrations if the matrix ion suppression varies for different samples in a run. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Improved Large-Volume Sampler for the Collection of Bacterial Cells from Aerosol

    PubMed Central

    White, L. A.; Hadley, D. J.; Davids, D. E.; Naylor, R.

    1975-01-01

    A modified large-volume sampler was demonstrated to be an efficient device for the collection of mono-disperse aerosols of rhodamine B and poly-disperse aerosols of bacterial cells. Absolute efficiency for collection of rhodamine B varied from 100% with 5-μm particles to about 70% with 0.5-μm particles. The sampler concentrated the particles from 950 liters of air into a flow of between 1 and 2 ml of collecting fluid per min. Spores of Bacillus subtilis var. niger were collected at an efficiency of about 82% compared to the collection in the standard AGI-30 sampler. In the most desirable collecting fluids tested, aerosolized cells of Serratia marcescens, Escherichia coli, and Aerobacter aerogenes were collected at comparative efficiencies of approximately 90, 80, and 90%, respectively. The modified sampler has practical application in the study of aerosol transmission of respiratory pathogens. Images PMID:803820

  6. Diffusion lengths in irradiated N/P InP-on-Si solar cells

    NASA Technical Reports Server (NTRS)

    Wojtczuk, Steven; Colerico, Claudia; Summers, Geoffrey P.; Walters, Robert J.; Burke, Edward A.

    1996-01-01

    Indium phosphide (InP) solar cells were made on silicon (Si) wafers (InP/Si) by to take advantage of both the radiation-hardness properties of the InP solar cell and the light weight and low cost of Si wafers. The InP/Si cell application is for long duration and/or high radiation orbit space missions. Spire has made N/P InP/Si cells of sizes up to 2 cm by 4 cm with beginning-of-life (BOL) AM0 efficiencies over 13% (one-sun, 28C). These InP/Si cells have higher absolute efficiency and power density after a high radiation dose than gallium arsenide (GaAs) or silicon (Si) solar cells after a fluence of about 2e15 1 MeV electrons/sq. cm. In this work, we investigate the minority carrier (electron) base diffusion lengths in the N/P InP/Si cells. A quantum efficiency model was constructed for a 12% BOL AM0 N/P InP/Si cell which agreed well with the absolutely measured quantum efficiency and the sun-simulator measured AM0 photocurrent (30.1 mA/sq. cm). This model was then used to generate a table of AM0 photocurrents for a range of base diffusion lengths. AM0 photocurrents were then measured for irradiations up to 7.7e16 1 MeV electrons/sq. cm (the 12% BOL cell was 8% after the final irradiation). By comparing the measured photocurrents with the predicted photocurrents, base diffusion lengths were assigned at each fluence level. A damage coefficient K of 4e-8 and a starting (unirradiated) base electron diffusion length of 0.8 microns fits the data well. The quantum efficiency was measured again at the end of the experiment to verify that the photocurrent predicted by the model (25.5 mA/sq. cm) agreed with the simulator-measured photocurrent after irradiation (25.7 mA/sq. cm).

  7. Development of a Protein Standard Absolute Quantification (PSAQ™) assay for the quantification of Staphylococcus aureus enterotoxin A in serum.

    PubMed

    Adrait, Annie; Lebert, Dorothée; Trauchessec, Mathieu; Dupuis, Alain; Louwagie, Mathilde; Masselon, Christophe; Jaquinod, Michel; Chevalier, Benoît; Vandenesch, François; Garin, Jérôme; Bruley, Christophe; Brun, Virginie

    2012-06-06

    Enterotoxin A (SEA) is a staphylococcal virulence factor which is suspected to worsen septic shock prognosis. However, the presence of SEA in the blood of sepsis patients has never been demonstrated. We have developed a mass spectrometry-based assay for the targeted and absolute quantification of SEA in serum. To enhance sensitivity and specificity, we combined an immunoaffinity-based sample preparation with mass spectrometry analysis in the selected reaction monitoring (SRM) mode. Absolute quantification of SEA was performed using the PSAQ™ method (Protein Standard Absolute Quantification), which uses a full-length isotope-labeled SEA as internal standard. The lower limit of detection (LLOD) and lower limit of quantification (LLOQ) were estimated at 352pg/mL and 1057pg/mL, respectively. SEA recovery after immunocapture was determined to be 7.8±1.4%. Therefore, we assumed that less than 1femtomole of each SEA proteotypic peptide was injected on the liquid chromatography column before SRM analysis. From a 6-point titration experiment, quantification accuracy was determined to be 77% and precision at LLOQ was lower than 5%. With this sensitive PSAQ-SRM assay, we expect to contribute to decipher the pathophysiological role of SEA in severe sepsis. This article is part of a Special Issue entitled: Proteomics: The clinical link. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. What do men understand about lifetime risk following genetic testing? The effect of context and numeracy.

    PubMed

    Rolison, Jonathan J; Hanoch, Yaniv; Miron-Shatz, Talya

    2012-07-01

    Genetic testing for gene mutations associated with specific cancers provides an opportunity for early detection, surveillance, and intervention (Smith, Cokkinides, & Brawley, 2008). Lifetime risk estimates provided by genetic testing refer to the risk of developing a specific disease within one's lifetime, and evidence suggests that this is important for the medical choices people make, as well as their future family and financial plans. The present studies tested whether adult men understand the lifetime risks of prostate cancer informed by genetic testing. In 2 experiments, adult men were asked to interpret the lifetime risk information provided in statements about risks of prostate cancer. Statement format was manipulated such that the most appropriate interpretation of risk statements referred to an absolute risk of cancer in experiment 1 and a relative risk in experiment 2. Experiment 1 revealed that few men correctly interpreted the lifetime risks of cancer when these refer to an absolute risk of cancer, and numeracy levels positively predicted correct responding. The proportion of correct responses was greatly improved in experiment 2 when the most appropriate interpretation of risk statements referred instead to a relative rather than an absolute risk, and numeracy levels were less involved. Understanding of lifetime risk information is often poor because individuals incorrectly believe that these refer to relative rather than absolute risks of cancer.

  9. Can the analyte-triggered asymmetric autocatalytic Soai reaction serve as a universal analytical tool for measuring enantiopurity and assigning absolute configuration?

    PubMed

    Welch, Christopher J; Zawatzky, Kerstin; Makarov, Alexey A; Fujiwara, Satoshi; Matsumoto, Arimasa; Soai, Kenso

    2016-12-20

    An investigation is reported on the use of the autocatalytic enantioselective Soai reaction, known to be influenced by the presence of a wide variety of chiral materials, as a generic tool for measuring the enantiopurity and absolute configuration of any substance. Good generality for the reaction across a small group of test analytes was observed, consistent with literature reports suggesting a diversity of compound types that can influence the stereochemical outcome of this reaction. Some trends in the absolute sense of stereochemical enrichment were noted, suggesting the possible utility of the approach for assigning absolute configuration to unknown compounds, by analogy to closely related species with known outcomes. Considerable variation was observed in the triggering strength of different enantiopure materials, an undesirable characteristic when dealing with mixtures containing minor impurities with strong triggering strength in the presence of major components with weak triggering strength. A strong tendency of the reaction toward an 'all or none' type of behavior makes the reaction most sensitive for detecting enantioenrichment close to zero. Consequently, the ability to discern modest from excellent enantioselectivity was relatively poor. While these properties limit the ability to obtain precise enantiopurity measurements in a simple single addition experiment, prospects may exist for more complex experimental setups that may potentially offer improved performance.

  10. A Calibration Method for Nanowire Biosensors to Suppress Device-to-device Variation

    PubMed Central

    Ishikawa, Fumiaki N.; Curreli, Marco; Chang, Hsiao-Kang; Chen, Po-Chiang; Zhang, Rui; Cote, Richard J.; Thompson, Mark E.; Zhou, Chongwu

    2009-01-01

    Nanowire/nanotube biosensors have stimulated significant interest; however the inevitable device-to-device variation in the biosensor performance remains a great challenge. We have developed an analytical method to calibrate nanowire biosensor responses that can suppress the device-to-device variation in sensing response significantly. The method is based on our discovery of a strong correlation between the biosensor gate dependence (dIds/dVg) and the absolute response (absolute change in current, ΔI). In2O3 nanowire based biosensors for streptavidin detection were used as the model system. Studying the liquid gate effect and ionic concentration dependence of strepavidin sensing indicates that electrostatic interaction is the dominant mechanism for sensing response. Based on this sensing mechanism and transistor physics, a linear correlation between the absolute sensor response (ΔI) and the gate dependence (dIds/dVg) is predicted and confirmed experimentally. Using this correlation, a calibration method was developed where the absolute response is divided by dIds/dVg for each device, and the calibrated responses from different devices behaved almost identically. Compared to the common normalization method (normalization of the conductance/resistance/current by the initial value), this calibration method was proved advantageous using a conventional transistor model. The method presented here substantially suppresses device-to-device variation, allowing the use of nanosensors in large arrays. PMID:19921812

  11. Enumeration of antigen-specific CD8+ T lymphocytes by single-platform, HLA tetramer-based flow cytometry: a European multicenter evaluation.

    PubMed

    Heijnen, Ingmar A F M; Barnett, David; Arroz, Maria J; Barry, Simon M; Bonneville, Marc; Brando, Bruno; D'hautcourt, Jean-Luc; Kern, Florian; Tötterman, Thomas H; Marijt, Erik W A; Bossy, David; Preijers, Frank W M B; Rothe, Gregor; Gratama, Jan W

    2004-11-01

    HLA class I peptide tetramers represent powerful diagnostic tools for detection and monitoring of antigen-specific CD8(+) T cells. The impetus for the current multicenter study is the critical need to standardize tetramer flow cytometry if it is to be implemented as a routine diagnostic assay. Hence, the European Working Group on Clinical Cell Analysis set out to develop and evaluate a single-platform tetramer-based method that used cytomegalovirus (CMV) as the antigenic model. Absolute numbers of CMV-specific CD8(+) T cells were obtained by combining the percentage of tetramer-binding cells with the absolute CD8(+) T-cell count. Six send-outs of stabilized blood from healthy individuals or CMV-carrying donors with CMV-specific CD8(+) T-cell counts of 3 to 10 cells/microl were distributed to 7 to 16 clinical sites. These sites were requested to enumerate CD8(+) T cells and, in the case of CMV-positive donors, CMV-specific subsets on three separate occasions using the standard method. Between-site coefficients of variation of less than 10% (absolute CD8(+) T-cell counts) and approximately 30% (percentage and absolute numbers of CMV-specific CD8(+) T cells) were achieved. Within-site coefficients of variation were approximately 5% (absolute CD8(+) T-cell counts), approximately 9% (percentage CMV-specific CD8(+) T cells), and approximately 17% (absolute CMV-specific CD8(+) T-cell counts). The degree of variation tended to correlate inversely with the proportion of CMV-specific CD8(+) T-cell subsets. The single-platform MHC tetramer-based method for antigen-specific CD8(+) T-cell counting has been evaluated by a European group of laboratories and can be considered a reproducible assay for routine enumeration of antigen-specific CD8(+) T cells. (c) 2004 Wiley-Liss, Inc.

  12. A system for automatic aorta sections measurements on chest CT

    NASA Astrophysics Data System (ADS)

    Pfeffer, Yitzchak; Mayer, Arnaldo; Zholkover, Adi; Konen, Eli

    2016-03-01

    A new method is proposed for caliber measurement of the ascending aorta (AA) and descending aorta (DA). A key component of the method is the automatic detection of the carina, as an anatomical landmark around which an axial volume of interest (VOI) can be defined to observe the aortic caliber. For each slice in the VOI, a linear profile line connecting the AA with the DA is found by pattern matching on the underlying intensity profile. Next, the aortic center position is found using Hough transform on the best linear segment candidate. Finally, region growing around the center provides an accurate segmentation and caliber measurement. We evaluated the algorithm on 113 sequential chest CT scans, slice thickness of 0.75 - 3.75mm, 90 with contrast agent injected. The algorithm success rates were computed as the percentage of scans in which the center of the AA was found. Automated measurements of AA caliber were compared with independent measurements of two experienced chest radiologists, comparing the absolute difference between the two radiologists with the absolute difference between the algorithm and each of the radiologists. The measurement stability was demonstrated by computing the STD of the absolute difference between the radiologists, and between the algorithm and the radiologists. Results: Success rates of 93% and 74% were achieved, for contrast injected cases and non-contrast cases, respectively. These results indicate that the algorithm can be robust in large variability of image quality, such as the cases in a realworld clinical setting. The average absolute difference between the algorithm and the radiologists was 1.85mm, lower than the average absolute difference between the radiologists, which was 2.1mm. The STD of the absolute difference between the algorithm and the radiologists was 1.5mm vs 1.6mm between the two radiologists. These results demonstrate the clinical relevance of the algorithm measurements.

  13. Metal Stable Isotope Tagging: Renaissance of Radioimmunoassay for Multiplex and Absolute Quantification of Biomolecules.

    PubMed

    Liu, Rui; Zhang, Shixi; Wei, Chao; Xing, Zhi; Zhang, Sichun; Zhang, Xinrong

    2016-05-17

    The unambiguous quantification of biomolecules is of great significance in fundamental biological research as well as practical clinical diagnosis. Due to the lack of a detectable moiety, the direct and highly sensitive quantification of biomolecules is often a "mission impossible". Consequently, tagging strategies to introduce detectable moieties for labeling target biomolecules were invented, which had a long and significant impact on studies of biomolecules in the past decades. For instance, immunoassays have been developed with radioisotope tagging by Yalow and Berson in the late 1950s. The later languishment of this technology can be almost exclusively ascribed to the use of radioactive isotopes, which led to the development of nonradioactive tagging strategy-based assays such as enzyme-linked immunosorbent assay, fluorescent immunoassay, and chemiluminescent and electrochemiluminescent immunoassay. Despite great success, these strategies suffered from drawbacks such as limited spectral window capacity for multiplex detection and inability to provide absolute quantification of biomolecules. After recalling the sequences of tagging strategies, an apparent question is why not use stable isotopes from the start? A reasonable explanation is the lack of reliable means for accurate and precise quantification of stable isotopes at that time. The situation has changed greatly at present, since several atomic mass spectrometric measures for metal stable isotopes have been developed. Among the newly developed techniques, inductively coupled plasma mass spectrometry is an ideal technique to determine metal stable isotope-tagged biomolecules, for its high sensitivity, wide dynamic linear range, and more importantly multiplex and absolute quantification ability. Since the first published report by our group, metal stable isotope tagging has become a revolutionary technique and gained great success in biomolecule quantification. An exciting research highlight in this area is the development and application of the mass cytometer, which fully exploited the multiplexing potential of metal stable isotope tagging. It realized the simultaneous detection of dozens of parameters in single cells, accurate immunophenotyping in cell populations, through modeling of intracellular signaling network and undoubted discrimination of function and connection of cell subsets. Metal stable isotope tagging has great potential applications in hematopoiesis, immunology, stem cells, cancer, and drug screening related research and opened a post-fluorescence era of cytometry. Herein, we review the development of biomolecule quantification using metal stable isotope tagging. Particularly, the power of multiplex and absolute quantification is demonstrated. We address the advantages, applicable situations, and limitations of metal stable isotope tagging strategies and propose suggestions for future developments. The transfer of enzymatic or fluorescent tagging to metal stable isotope tagging may occur in many aspects of biological and clinical practices in the near future, just as the revolution from radioactive isotope tagging to fluorescent tagging happened in the past.

  14. Scintillation detector efficiencies for neutrons in the energy region above 20 MeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dickens, J.K.

    1991-01-01

    The computer program SCINFUL (for SCINtillator FUL1 response) is a program designed to provide a calculated complete pulse-height response anticipated for neutrons being detected by either an NE-213 (liquid) scintillator or an NE-110 (solid) scintillator in the shape of a right circular cylinder. The point neutron source may be placed at any location with respect to the detector, even inside of it. The neutron source may be monoenergetic, or Maxwellian distributed, or distributed between chosen lower and upper bounds. The calculational method uses Monte Carlo techniques, and it is relativistically correct. Extensive comparisons with a variety of experimental data havemore » been made. There is generally overall good agreement (less than 10% differences) of results for SCINFUL calculations with measured integral detector efficiencies for the design incident neutron energy range of 0.1 to 80 MeV. Calculations of differential detector responses, i.e. yield versus response pulse height, are generally within about 5% on the average for incident neutron energies between 16 and 50 MeV and for the upper 70% of the response pulse height. For incident neutron energies between 50 and 80 MeV, the calculated shape of the response agrees with measurements, but the calculations tend to underpredict the absolute values of the measured responses. Extension of the program to compute responses for incident neutron energies greater than 80 MeV will require new experimental data on neutron interactions with carbon. 32 refs., 6 figs., 2 tabs.« less

  15. Scintillation detector efficiencies for neutrons in the energy region above 20 MeV

    NASA Astrophysics Data System (ADS)

    Dickens, J. K.

    The computer program SCINFUL (for SCINtillator FUL1 response) is a program designed to provide a calculated complete pulse-height response anticipated for neutrons being detected by either an NE-213 (liquid) scintillator or an NE-110 (solid) scintillator in the shape of a right circular cylinder. The point neutron source may be placed at any location with respect to the detector, even inside of it. The neutron source may be monoenergetic, or Maxwellian distributed, or distributed between chosen lower and upper bounds. The calculational method uses Monte Carlo techniques, and it is relativistically correct. Extensive comparisons with a variety of experimental data were made. There is generally overall good agreement (less than 10 pct. differences) of results for SCINFUL calculations with measured integral detector efficiencies for the design incident neutron energy range of 0.1 to 80 MeV. Calculations of differential detector responses, i.e., yield versus response pulse height, are generally within about 5 pct. on the average for incident neutron energies between 16 and 50 MeV and for the upper 70 pct. of the response pulse height. For incident neutron energies between 50 and 80 MeV, the calculated shape of the response agrees with measurements, but the calculations tend to underpredict the absolute values of the measured responses. Extension of the program to compute responses for incident neutron energies greater than 80 MeV will require new experimental data on neutron interactions with carbon.

  16. A novel magnetic poly(aniline-naphthylamine)-based nanocomposite for micro solid phase extraction of rhodamine B.

    PubMed

    Bagheri, Habib; Daliri, Rasoul; Roostaie, Ali

    2013-09-10

    A novel Fe3O4-poly(aniline-naphthylamine)-based nanocomposite was synthesized by chemical oxidative polymerization process as a magnetic sorbent for micro solid phase extraction. The scanning electron microscopy images of the synthesized nanocomposite revealed that the copolymer posses a porous structure with diameters less than 50nm. The extraction efficiency of this sorbent was examined by isolation of rhodamine B, a mutagenic and carcinogenic dye, from aquatic media in dispersion mode. Among different synthesized polymers, Fe3O4/poly(aniline-naphthylamine) nanocomposite showed a prominent efficiency. Parameters including the desorption solvent, amount of sorbent, desorption time, sample pH, ionic strength, extraction time and stirring rate were optimized. Under the optimum condition, a linear spiked calibration curve in the range of 0.35-5.00μgL(-1) with R(2)=0.9991 was obtained. The limits of detection (3Sb) and limits of quantification (10Sb) of the method were 0.10μgL(-1) and 0.35μgL(-1) (n=3), respectively. The relative standard deviation for water sample with 0.5μgL(-1) of RhB was 4.2% (n=5) and the absolute recovery was 92%. The method was applied for the determination of rhodamine B in dishwashing foam, dishwashing liquid, shampoo, pencil, matches tips and eye shadows samples and the relative recovery percentage were in the range of 94-99%. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Improvement in ionization efficiency of direct analysis in real time-mass spectrometry (DART-MS) by corona discharge.

    PubMed

    Sekimoto, Kanako; Sakakura, Motoshi; Kawamukai, Takatomo; Hike, Hiroshi; Shiota, Teruhisa; Usui, Fumihiko; Bando, Yasuhiko; Takayama, Mitsuo

    2016-08-02

    Herein it is shown that a combination of direct analysis in real time (DART) with a corona discharge system consisting of only a needle electrode easily improves DART ionization efficiency. Positive and negative DC corona discharges led to a formation of abundant excited helium atoms as well as the reactant ions H3O(+)(H2O)n and O2˙(-) in the DART analyte ionization area. These phenomena resulted in an increase in the absolute intensities of (de)protonated analytes by a factor of 2-20 over conventional DART. The other analyte ions detected in this corona-DART system (i.e., molecular ions, fragment ions, oxygenated (de)protonated analytes, dehydrogenated deprotonated analytes, and negative ion adducts) were quite similar to those obtained from DART alone. This indicates a lack of side reactions due to the corona discharge. The change in the relative intensities of individual analyte-related ions due to the combination of a corona discharge system with DART suggests that there is no effect of the abundant excited helium in the analyte ionization area on the fragmentation processes or enhancement of oxidation due to hydroxyl radicals HO˙. Furthermore, it was found that the corona-DART combination can be applied to the highly sensitive analysis of n-alkanes, in which the alkanes are ionized as positive ions via hydride abstraction and oxidation, independent of the type of alkane or the mass spectrometer used.

  18. Identification of racial disparities in breast cancer mortality: does scale matter?

    PubMed

    Tian, Nancy; Goovaerts, Pierre; Zhan, F Benjamin; Wilson, Jeff G

    2010-07-05

    This paper investigates the impact of geographic scale (census tract, zip code, and county) on the detection of disparities in breast cancer mortality among three ethnic groups in Texas (period 1995-2005). Racial disparities were quantified using both relative (RR) and absolute (RD) statistics that account for the population size and correct for unreliable rates typically observed for minority groups and smaller geographic units. Results were then correlated with socio-economic status measured by the percentage of habitants living below the poverty level. African-American and Hispanic women generally experience higher mortality than White non-Hispanics, and these differences are especially significant in the southeast metropolitan areas and southwest border of Texas. The proportion and location of significant racial disparities however changed depending on the type of statistic (RR versus RD) and the geographic level. The largest proportion of significant results was observed for the RD statistic and census tract data. Geographic regions with significant racial disparities for African-Americans and Hispanics frequently had a poverty rate above 10.00%. This study investigates both relative and absolute racial disparities in breast cancer mortality between White non-Hispanic and African-American/Hispanic women at the census tract, zip code and county levels. Analysis at the census tract level generally led to a larger proportion of geographical units experiencing significantly higher mortality rates for minority groups, although results varied depending on the use of the relative versus absolute statistics. Additional research is needed before general conclusions can be formulated regarding the choice of optimal geographic regions for the detection of racial disparities.

  19. Identification of racial disparities in breast cancer mortality: does scale matter?

    PubMed Central

    2010-01-01

    Background This paper investigates the impact of geographic scale (census tract, zip code, and county) on the detection of disparities in breast cancer mortality among three ethnic groups in Texas (period 1995-2005). Racial disparities were quantified using both relative (RR) and absolute (RD) statistics that account for the population size and correct for unreliable rates typically observed for minority groups and smaller geographic units. Results were then correlated with socio-economic status measured by the percentage of habitants living below the poverty level. Results African-American and Hispanic women generally experience higher mortality than White non-Hispanics, and these differences are especially significant in the southeast metropolitan areas and southwest border of Texas. The proportion and location of significant racial disparities however changed depending on the type of statistic (RR versus RD) and the geographic level. The largest proportion of significant results was observed for the RD statistic and census tract data. Geographic regions with significant racial disparities for African-Americans and Hispanics frequently had a poverty rate above 10.00%. Conclusions This study investigates both relative and absolute racial disparities in breast cancer mortality between White non-Hispanic and African-American/Hispanic women at the census tract, zip code and county levels. Analysis at the census tract level generally led to a larger proportion of geographical units experiencing significantly higher mortality rates for minority groups, although results varied depending on the use of the relative versus absolute statistics. Additional research is needed before general conclusions can be formulated regarding the choice of optimal geographic regions for the detection of racial disparities. PMID:20602784

  20. Physical activity and pregnancy: cardiovascular adaptations, recommendations and pregnancy outcomes.

    PubMed

    Melzer, Katarina; Schutz, Yves; Boulvain, Michel; Kayser, Bengt

    2010-06-01

    Regular physical activity is associated with improved physiological, metabolic and psychological parameters, and with reduced risk of morbidity and mortality. Current recommendations aimed at improving the health and well-being of nonpregnant subjects advise that an accumulation of > or =30 minutes of moderate physical activity should occur on most, if not all, days of the week. Regardless of the specific physiological changes induced by pregnancy, which are primarily developed to meet the increased metabolic demands of mother and fetus, pregnant women benefit from regular physical activity the same way as nonpregnant subjects. Changes in submaximal oxygen uptake (VO(2)) during pregnancy depend on the type of exercise performed. During maternal rest or submaximal weight-bearing exercise (e.g. walking, stepping, treadmill exercise), absolute maternal VO(2) is significantly increased compared with the nonpregnant state. The magnitude of change is approximately proportional to maternal weight gain. When pregnant women perform submaximal weight-supported exercise on land (e.g. level cycling), the findings are contradictory. Some studies reported significantly increased absolute VO(2), while many others reported unchanged or only slightly increased absolute VO(2) compared with the nonpregnant state. The latter findings may be explained by the fact that the metabolic demand of cycle exercise is largely independent of the maternal body mass, resulting in no absolute VO(2) alteration. Few studies that directly measured changes in maternal maximal VO(2) (VO(2max)) showed no difference in the absolute VO(2max) between pregnant and nonpregnant subjects in cycling, swimming or weight-bearing exercise. Efficiency of work during exercise appears to be unchanged during pregnancy in non-weight-bearing exercise. During weight-bearing exercise, the work efficiency was shown to be improved in athletic women who continue exercising and those who stop exercising during pregnancy. When adjusted for weight gain, the increased efficiency is maintained throughout the pregnancy, with the improvement being greater in exercising women. Regular physical activity has been proven to result in marked benefits for mother and fetus. Maternal benefits include improved cardiovascular function, limited pregnancy weight gain, decreased musculoskeletal discomfort, reduced incidence of muscle cramps and lower limb oedema, mood stability, attenuation of gestational diabetes mellitus and gestational hypertension. Fetal benefits include decreased fat mass, improved stress tolerance, and advanced neurobehavioural maturation. In addition, few studies that have directly examined the effects of physical activity on labour and delivery indicate that, for women with normal pregnancies, physical activity is accompanied with shorter labour and decreased incidence of operative delivery. However, a substantial proportion of women stop exercising after they discover they are pregnant, and only few begin participating in exercise activities during pregnancy. The adoption or continuation of a sedentary lifestyle during pregnancy may contribute to the development of certain disorders such as hypertension, maternal and childhood obesity, gestational diabetes, dyspnoea, and pre-eclampsia. In view of the global epidemic of sedentary behaviour and obesity-related pathology, prenatal physical activity was shown to be useful for the prevention and treatment of these conditions. Further studies with larger sample sizes are required to confirm the association between physical activity and outcomes of labour and delivery.

  1. Designation of a polarization-converting system and its enhancement of double-frequency efficiency

    NASA Astrophysics Data System (ADS)

    Wang, Peng; Li, Xiao; Shang, YaPing; Xu, XiaoJun

    2015-08-01

    A polarization-converting system is designed by using axicons and wave plate transforming naturally polarized laser to linearly polarized laser at real time to resolve difficulties of generating high-power linearly polarized laser. The energy conversion efficiency reaches 96.9% with an enhancement of extinction ratio from 29.7% to 98%. The system also keeps excellent far field divergence. In the one-way SHG experiment the double frequency efficiency reached 4.32% using the generated linearly polarized laser, much higher than that of the naturally polarized laser but lower than that of the linearly polarized laser from PBS. And the phenomenon of the SHG experiment satisfies the principle of phase matching. The experiment proves that this polarization-converting system will not affect laser structure which controls easily and needs no feedback and controlling system with stable and reliable properties at the same time. It can absolutely be applied to the polarization-conversion of high power laser and enhance the SHG efficiency and the energy efficiency.

  2. Accurate reconstruction of the jV-characteristic of organic solar cells from measurements of the external quantum efficiency

    NASA Astrophysics Data System (ADS)

    Meyer, Toni; Körner, Christian; Vandewal, Koen; Leo, Karl

    2018-04-01

    In two terminal tandem solar cells, the current density - voltage (jV) characteristic of the individual subcells is typically not directly measurable, but often required for a rigorous device characterization. In this work, we reconstruct the jV-characteristic of organic solar cells from measurements of the external quantum efficiency under applied bias voltages and illumination. We show that it is necessary to perform a bias irradiance variation at each voltage and subsequently conduct a mathematical correction of the differential to the absolute external quantum efficiency to obtain an accurate jV-characteristic. Furthermore, we show that measuring the external quantum efficiency as a function of voltage for a single bias irradiance of 0.36 AM1.5g equivalent sun provides a good approximation of the photocurrent density over voltage curve. The method is tested on a selection of efficient, common single-junctions. The obtained conclusions can easily be transferred to multi-junction devices with serially connected subcells.

  3. Performance Study of Earth Networks Total Lightning Network using Rocket-Triggered Lightning Data in 2014

    NASA Astrophysics Data System (ADS)

    Heckman, S.

    2015-12-01

    Modern lightning locating systems (LLS) provide real-time monitoring and early warning of lightningactivities. In addition, LLS provide valuable data for statistical analysis in lightning research. It isimportant to know the performance of such LLS. In the present study, the performance of the EarthNetworks Total Lightning Network (ENTLN) is studied using rocket-triggered lightning data acquired atthe International Center for Lightning Research and Testing (ICLRT), Camp Blanding, Florida.In the present study, 18 flashes triggered at ICLRT in 2014 were analyzed and they comprise of 78negative cloud-to-ground return strokes. The geometric mean, median, minimum, and maximum for thepeak currents of the 78 return strokes are 13.4 kA, 13.6 kA, 3.7 kA, and 38.4 kA, respectively. The peakcurrents represent typical subsequent return strokes in natural cloud-to-ground lightning.Earth Networks has developed a new data processor to improve the performance of their network. Inthis study, results are presented for the ENTLN data using the old processor (originally reported in 2014)and the ENTLN data simulated using the new processor. The flash detection efficiency, stroke detectionefficiency, percentage of misclassification, median location error, median peak current estimation error,and median absolute peak current estimation error for the originally reported data from old processorare 100%, 94%, 49%, 271 m, 5%, and 13%, respectively, and those for the simulated data using the newprocessor are 100%, 99%, 9%, 280 m, 11%, and 15%, respectively. The use of new processor resulted inhigher stroke detection efficiency and lower percentage of misclassification. It is worth noting that theslight differences in median location error, median peak current estimation error, and median absolutepeak current estimation error for the two processors are due to the fact that the new processordetected more number of return strokes than the old processor.

  4. Large-Area, Low-Cost, High-Efficiency Neutron Detector for Vehicle-Mounted Operation

    NASA Astrophysics Data System (ADS)

    Lacy, Jeffrey L.; Martin, Christopher S.; Athanasiades, Athanasios; Regmi, Murari; Vazquez-Flores, Gerson J.; Davenport, Stephen; King, Nicholas S.; Lyons, Tom

    2017-07-01

    We have developed a large-area, low-cost, high-efficiency neutron detector for vehicle-mounted operation. The detector, which has overall dimensions 12.7 cm x 91.4 cm x 102 cm (5”x36”x40”), a sensitive area equal to 0.85 m2 (1320 in2), and weight of 110 kg (242 lbs), employs an array of 90 boron-coated straw (BCS) detectors. PTI has also developed electronics to minimize cost and space while providing low-noise signal conditioning for both neutron and gamma detection channels, as well as low energy Bluetooth communication with handheld devices. Extremely low power consumption allows continuous use for 225 hours (-.10 days) using three AAA lithium-ion rechargeable batteries. We present radiological, mechanical, and environmental tests, collected from four full-scale prototypes. Outdoor neutron-counting tests with a moderated 252Cf source 2 m away from the center of the detector face showed an average detection rate of 5.5 cps/ng with a standard deviation of 0.09 cps/ng over the four individual detector measurements. Measurements showed a gamma rejection ratio of 1.0 x 10-8, and gamma absolute rejection ratio (GARRn) of 0.93. The prototypes were also operated successfully onboard a moving vehicle for high-speed tests and a long-range 1433-mile, two-day road trip from Houston, TX, USA, to Laurel, MD, USA. Using auxiliary DARPA SIGMA equipment, the GPS, timestamp, gamma and neutron data were transmitted over the cellular network with 10 Hz resolution to a server and real-time tracking website. Mechanical impact and electrostatic discharge testing produced no spurious counts in either the neutron or gamma channels. Ambient environmental temperature testing showed less than ±1% response variation over the range from -30°C to +55°C.

  5. Microbial rRNA: rDNA gene ratios may be unexpectedly low due to extracellular DNA preservation in soils

    USDA-ARS?s Scientific Manuscript database

    We tested a method of estimating the activity of detectable individual bacterial and archaeal OTUs within a community by calculating ratios of absolute 16S rRNA to rDNA copy numbers. We investigated phylogenetically coherent patterns of activity among soil prokaryotes in non-growing soil communitie...

  6. Application of droplet digital PCR for quantitative detection of Spiroplasma citri in comparison with real time PCR

    USDA-ARS?s Scientific Manuscript database

    Droplet digital Polymerase chain reaction (ddPCR) is a unique approach to measure the absolute copy number of nucleic acid targets without the need of external standards. It is a promising DNA quantification technology for medical diagnostics but there are only a few reports of its use for plant pat...

  7. Radiometric correction of multi-temporal Landsat data for characterization of early successional forest patterns in western Oregon.

    Treesearch

    Todd A. Schroeder; Warren B. Cohen; Conghe Song; Morton J. Canty; Zhiqiang Yang

    2006-01-01

    Detecting and characterizing continuous changes in early forest succession using multi-temporal satellite imagery requires atmospheric correction procedures that are both operationally reliable, and that result in comparable units (e-g., surface reflectance). This paper presents a comparison of five atmospheric correction methods (2 relative, 3 absolute) used to...

  8. Modeling of the influence of humidity on H1N1 flu in China

    NASA Astrophysics Data System (ADS)

    PEI, Y.; Tian, H.; Xu, B.

    2015-12-01

    In 2009, a heavy Flu hit the whole world. It was caused by the virus H1N1. The influenza first broke out in Mexico in March and the United States in April, 2009. The World Health Organization (WHO) announced that the H1N1 influenza became pandemic, alert to a warning phase of six. By the end of 2011, 181302 H1N1 cases were reported in mainland China. To improve our understanding on the impact of environmental factors on the disease transmission, we constructed an SIR (Susceptible - Infectious - Recovered) model incorporating environmental factors. It was found that the absolute humidity was a dominant environmental factor. The study interpolated the humidity data monitored with 340 weather stations from 1951 to 2011 in mainland China. First, the break point of the trend for the absolutely humidity was detected by the BFAST (Break For Additive Season and Trend) method. Then, the SIR model with and without the absolutely humidity incorporated in the model was built and tested. Finally, the results with the two scenarios were compared. Results indicate that lower absolutely humidity may promote the transmission of the H1N1 cases. The calculated basic reproductive number ranges from 1.65 to 3.66 with a changing absolute humidity. This is consistent with the former study result with basic reproductive number ranging from 2.03 to 4.18. The average recovery duration was estimated to be 5.7 days. The average duration to get immunity from the influenza is 399.02 days. A risk map is also produced to illustrate the model results.

  9. On the Use of the Main-sequence Knee (Saddle) to Measure Globular Cluster Ages

    NASA Astrophysics Data System (ADS)

    Saracino, S.; Dalessandro, E.; Ferraro, F. R.; Lanzoni, B.; Origlia, L.; Salaris, M.; Pietrinferni, A.; Geisler, D.; Kalirai, J. S.; Correnti, M.; Cohen, R. E.; Mauro, F.; Villanova, S.; Moni Bidin, C.

    2018-06-01

    In this paper, we review the operational definition of the so-called main-sequence knee (MS-knee), a feature in the color-magnitude diagram (CMD) occurring at the low-mass end of the MS. The magnitude of this feature is predicted to be independent of age at fixed chemical composition. For this reason, its difference in magnitude with respect to the MS turn-off (MS-TO) point has been suggested as a possible diagnostic to estimate absolute globular cluster (GC) ages. We first demonstrate that the operational definition of the MS-knee currently adopted in the literature refers to the inflection point of the MS (which we here more appropriately named MS-saddle), a feature that is well distinct from the knee and which cannot be used as its proxy. The MS-knee is only visible in near-infrared CMDs, while the MS-saddle can be also detected in optical–NIR CMDs. By using different sets of isochrones, we then demonstrate that the absolute magnitude of the MS-knee varies by a few tenths of a dex from one model to another, thus showing that at the moment stellar models may not capture the full systematic error in the method. We also demonstrate that while the absolute magnitude of the MS-saddle is almost coincident in different models, it has a systematic dependence on the adopted color combinations which is not predicted by stellar models. Hence, it cannot be used as a reliable reference for absolute age determination. Moreover, when statistical and systematic uncertainties are properly taken into account, the difference in magnitude between the MS-TO and the MS-saddle does not provide absolute ages with better accuracy than other methods like the MS-fitting.

  10. Protection of SK-N-MC cells against β-amyloid peptide-induced degeneration using neuron growth factor-loaded liposomes with surface lactoferrin.

    PubMed

    Kuo, Yung-Chih; Wang, Cheng-Ting

    2014-07-01

    A liposomal system with surface lactoferrin (Lf) was developed for delivering neuron growth factor (NGF) across the blood-brain barrier (BBB) and improving the viability of neuron-like SK-N-MC cells with deposited β-amyloid peptide (Aβ). The Lf-grafted liposomes carrying NGF (Lf/NGF-liposomes) were applied to a monolayer of human brain-microvascular endothelial cells (HBMECs) regulated by human astrocytes (HAs) and to fibrillar Aβ1-42-insulted SK-N-MC cells. An increase in cholesterol mole percentage enhanced the particle size, absolute value of zeta potential, and physical stability, however, reduced the entrapment efficiency and release rate of NGF. In addition, an increase in Lf concentration increased the particle size, surface nitrogen percentage, NGF permeability across the BBB, and viability of HBMECs, HAs, and SK-N-MC cells, however, decreased the absolute value of zeta potential, surface phosphorus percentage, and loading efficiency of Lf. After treating with Lf/NGF-liposomes, a higher Aβ concentration yielded a lower survival of SK-N-MC cells. The current Lf/NGF-liposomes are efficacious drug carriers to target the BBB and inhibit the Aβ-induced neurotoxicity as potential pharmacotherapy for Alzheimer's disease. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Improvement of band gap profile in Cu(InGa)Se{sub 2} solar cells through rapid thermal annealing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, D.S.; College of Mathematics and Physics, Shanghai University of Electric Power, Shanghai, 200090; Yang, J.

    Highlights: • Proper RTA treatment can effectively optimize band gap profile to more expected level. • Inter-diffusion of atoms account for the improvement of the graded band gap profile. • The variation of the band gap profile created an absolute gain in the efficiency by 1.22%. - Abstract: In the paper, the effect of rapid thermal annealing on non-optimal double-graded band gap profiles was investigated by using X-ray photoelectron spectroscopy and capacitance–voltage measurement techniques. Experimental results revealed that proper rapid thermal annealing treatment can effectively improve band gap profile to more optimal level. The annealing treatment could not only reducemore » the values of front band gap and minimum band gap, but also shift the position of the minimum band gap toward front electrode and enter into space charge region. In addition, the thickness of Cu(InGa)Se{sub 2} thin film decreased by 25 nm after rapid thermal annealing treatment. All of these modifications were attributed to the inter-diffusion of atoms during thermal treatment process. Simultaneously, the variation of the band gap profile created an absolute gain in the efficiency by 1.22%, short-circuit current density by 2.16 mA/cm{sup 2} and filled factor by 3.57%.« less

  12. Cooperative and non-cooperative sensitization upconversion in lanthanide-doped LiYbF4 nanoparticles.

    PubMed

    Zou, Qilin; Huang, Ping; Zheng, Wei; You, Wenwu; Li, Renfu; Tu, Datao; Xu, Jin; Chen, Xueyuan

    2017-05-18

    Lanthanide (Ln 3+ )-doped upconversion nanoparticles (UCNPs) have attracted tremendous interest owing to their potential bioapplications. However, the intrinsic photophysics responsible for upconversion (UC) especially the cooperative sensitization UC (CSU) in colloidal Ln 3+ -doped UCNPs has remained untouched so far. Herein, we report a unique strategy for the synthesis of high-quality LiYbF 4 :Ln 3+ core-only and core/shell UCNPs with tunable particle sizes and shell thicknesses. Energy transfer UC from Er 3+ , Ho 3+ and Tm 3+ and CSU from Tb 3+ were comprehensively surveyed under 980 nm excitation. Through surface passivation, we achieved efficient non-cooperative sensitization UC with absolute UC quantum yields (QYs) of 3.36%, 0.69% and 0.81% for Er 3+ , Ho 3+ and Tm 3+ , respectively. Particularly, we for the first time quantitatively determined the CSU efficiency for Tb 3+ with an absolute QY of 0.0085% under excitation at a power density of 70 W cm -2 . By means of temperature-dependent steady-state and transient UC spectroscopy, we unraveled the dominant mechanisms of phonon-assisted cooperative energy transfer (T > 100 K) and sequential dimer ground-state absorption/excited-state absorption (T < 100 K) for the CSU process in LiYbF 4 :Tb 3+ UCNPs.

  13. Precision measurement of ^23Al beta-decay

    NASA Astrophysics Data System (ADS)

    Zhai, Yongjun; Iacob, V. E.; Hardy, J. C.; Al-Abdullah, T.; Banu, A.; Fu, C.; Golovko, V. V.; McCleskey, M.; Nica, N.; Park, H. I.; Tabacaru, G.; Tribble, R. E.; Trache, L.

    2007-10-01

    The beta-decay of ^23Al (See [1]) was re-measured with higher statistics and better accuracy at Texas A&M University. Using MARS we produced and separated pure ^23Al at 4000 pps, with a 48 MeV/u ^24Mg beam via the ^24Mg (p, 2n)^ 23Al reaction on a H2 cryogenic target. New β and β-γ coincidence measurements were made with a scintillator, an HPGe detector with BGO shielding and the fast tape transport system. The BGO Compton shield very much improved the quality of the γ spectra around the transition from the IAS state at 7803 keV. From the measured β singles and β-γ coincidence decay spectra we obtained an improved β-decay scheme and a more precise lifetime: t=447(4) ms. We use the method of detailed balance to obtain absolute β-branching ratios and absolute logft values for transitions to final states in ^23Mg. For this method, precise efficiency calibration of the HPGe detector up to about 8 MeV is needed. We extended our previous efficiency calibration to the range Eγ=3.5-8 MeV using the β-decay of ^24Al. [1] V.E. Iacob, Y. Zhai et al., Phys. Rev. C 74, 045810 (2006).

  14. Bed turbulent kinetic energy boundary conditions for trapping efficiency and spatial distribution of sediments in basins.

    PubMed

    Isenmann, Gilles; Dufresne, Matthieu; Vazquez, José; Mose, Robert

    2017-10-01

    The purpose of this study is to develop and validate a numerical tool for evaluating the performance of a settling basin regarding the trapping of suspended matter. The Euler-Lagrange approach was chosen to model the flow and sediment transport. The numerical model developed relies on the open source library OpenFOAM ® , enhanced with new particle/wall interaction conditions to limit sediment deposition in zones with favourable hydrodynamic conditions (shear stress, turbulent kinetic energy). In particular, a new relation is proposed for calculating the turbulent kinetic energy threshold as a function of the properties of each particle (diameter and density). The numerical model is compared to three experimental datasets taken from the literature and collected for scale models of basins. The comparison of the numerical and experimental results permits concluding on the model's capacity to predict the trapping of particles in a settling basin with an absolute error in the region of 5% when the sediment depositions occur over the entire bed. In the case of sediment depositions localised in preferential zones, their distribution is reproduced well by the model and trapping efficiency is evaluated with an absolute error in the region of 10% (excluding cases of particles with very low density).

  15. Evaluation of the KCl Denuder Method for Gaseous Oxidized Mercury using HgBr2 at an In-Service AMNet Site

    NASA Astrophysics Data System (ADS)

    McClure, Crystal

    During the summer of 2013, we examined the performance of KCl-coated denuders for measuring gaseous oxidized mercury (GOM) by calibrating with a known source of GOM (i.e., HgBr2) at the North Birmingham SouthEastern Aerosol Research and Characterization (SEARCH) site. We found that KCl-coated denuders have near 95% collection efficiency for HgBr2 in zero air (i.e., air scrubbed of mercury and ozone). However, in ambient air, the efficiency of KCl-coated denuders in capturing HgBr2 dropped to 20-54%. We also found that absolute humidity and ozone each demonstrate a significant inverse correlation with HgBr2 recovery in ambient air. Subsequent laboratory tests with HgBr2 and the KCl-coated denuder show that ozone and absolute humidity cause the release of gaseous elemental Hg from the denuder and thus appear to explain the low recovery in ambient air. Based on these findings, we infer that the KCl denuder method underestimates atmospheric GOM concentrations. A calibration system is needed to accurately measure GOM. The system described in this paper for HgBr2 could be implemented with existing mercury speciation instrumentation and this would improve our knowledge of the response to one potentially important GOM compound.

  16. A soil-column gas chromatography (SCGC) approach to explore the thermal desorption behavior of hydrocarbons from soils.

    PubMed

    Yu, Ying; Liu, Liang; Shao, Ziying; Ju, Tianyu; Sun, Bing; Benadda, Belkacem

    2016-01-01

    A soil-column gas chromatography approach was developed to simulate the mass transfer process of hydrocarbons between gas and soil during thermally enhanced soil vapor extraction (T-SVE). Four kinds of hydrocarbons-methylbenzene, n-hexane, n-decane, and n-tetradecane-were flowed by nitrogen gas. The retention factor k' and the tailing factor T f were calculated to reflect the desorption velocities of fast and slow desorption fractions, respectively. The results clearly indicated two different mechanisms on the thermal desorption behaviors of fast and slow desorption fractions. The desorption velocity of fast desorption fraction was an exponential function of the reciprocal of soil absolute temperature and inversely correlated with hydrocarbon's boiling point, whereas the desorption velocity of slow desorption fraction was an inverse proportional function of soil absolute temperature, and inversely proportional to the log K OW value of the hydrocarbons. The higher activation energy of adsorption was found on loamy soil with higher organic content. The increase of carrier gas flow rate led to a reduction in the apparent activation energy of adsorption of slow desorption fraction, and thus desorption efficiency was significantly enhanced. The obtained results are of practical interest for the design of high-efficiency T-SVE system and may be used to predict the remediation time.

  17. 3D prostate MR-TRUS non-rigid registration using dual optimization with volume-preserving constraint

    NASA Astrophysics Data System (ADS)

    Qiu, Wu; Yuan, Jing; Fenster, Aaron

    2016-03-01

    We introduce an efficient and novel convex optimization-based approach to the challenging non-rigid registration of 3D prostate magnetic resonance (MR) and transrectal ultrasound (TRUS) images, which incorporates a new volume preserving constraint to essentially improve the accuracy of targeting suspicious regions during the 3D TRUS guided prostate biopsy. Especially, we propose a fast sequential convex optimization scheme to efficiently minimize the employed highly nonlinear image fidelity function using the robust multi-channel modality independent neighborhood descriptor (MIND) across the two modalities of MR and TRUS. The registration accuracy was evaluated using 10 patient images by calculating the target registration error (TRE) using manually identified corresponding intrinsic fiducials in the whole prostate gland. We also compared the MR and TRUS manually segmented prostate surfaces in the registered images in terms of the Dice similarity coefficient (DSC), mean absolute surface distance (MAD), and maximum absolute surface distance (MAXD). Experimental results showed that the proposed method with the introduced volume-preserving prior significantly improves the registration accuracy comparing to the method without the volume-preserving constraint, by yielding an overall mean TRE of 2:0+/-0:7 mm, and an average DSC of 86:5+/-3:5%, MAD of 1:4+/-0:6 mm and MAXD of 6:5+/-3:5 mm.

  18. Sequential liquid biopsies reveal dynamic alterations of EGFR driver mutations and indicate EGFR amplification as a new mechanism of resistance to osimertinib in NSCLC.

    PubMed

    Knebel, Franciele H; Bettoni, Fabiana; Shimada, Andrea K; Cruz, Manoel; Alessi, João Victor; Negrão, Marcelo V; Reis, Luiz Fernando L; Katz, Artur; Camargo, Anamaria A

    2017-06-01

    Osimertinib is an EGFR-T790M-specific TKI, which has demonstrated impressive response rates in NSCLC, after failure to first-line anti-EGFR TKIs. However, acquired resistance to osimertinib is also observed and the molecular mechanisms of resistance are not yet fully understood. Monitoring and managing NSCLC patients who progressed on osimertinib is, therefore, emerging as an important clinical challenge. Sequential liquid biopsies were used to monitor a patient with EGFR-exon19del positive NSCLC, who received erlotinib and progressed through the acquisition of the EGFR-T790M mutation. Erlotinib was discontinued and osimertinib was initiated. Blood samples were collected at erlotinib progression and during osimertinib treatment for the detection of the activating (EGFR-exon19del) and resistance mutations (EGFR-T790M, EGFR-C797S, BRAF-V600E, METamp and ERBB2amp) in the plasma DNA using digital droplet PCR. Plasma levels of the activating EGFR-exon19del accurately paralleled the clinical and radiological progression of disease and allowed early detection of AR to osimertinib. Resistance to osimertinib coincided with the emergence of a small tumor cell subpopulation carrying the known EGFR-C797S resistance mutation and an additional subpopulation carrying amplified copies of EGFR-exon19del. Given the existence of multiple AR mechanisms, quantification of the original EGFR activation mutation, instead of the resistance mutations, can be efficiently used to monitor response to osimertinib, allowing early detection of AR. Absolute quantification of both activation and resistance mutations can provide important information on tumor clonal evolution upon progression to osimertinib. Selective amplification of the EGFR-exon19del allele may represent a novel resistance mechanism to osimertinib. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development of a GC/C/IRMS method--confirmation of a novel steroid profiling approach in doping control.

    PubMed

    Van Renterghem, Pieter; Polet, Michael; Brooker, Lance; Van Gansbeke, Wim; Van Eenoo, Peter

    2012-09-01

    In doping control, an athlete can only be convicted with the misuse with endogenous steroids like testosterone (T), if abnormal values of steroid metabolites and steroid ratios are observed and if the subsequent analysis with isotope ratios mass spectrometry (IRMS) confirms the presence of exogenously administered androgens. In this work, we compare the results of a novel steroid profiling approach with the performance an in-house developed IRMS method. The developed IRMS has the advantage over other methods to be relatively short in time and with target compounds androsterone, etiocholanolone, 5β-androstane 3α,17β-diol and 5α-androstane 3α,17β-diol. Pregnanediol was used as an endogenous reference compound (ERC). Reference limits for the IRMS values were established and applied as decision limits for the evaluation of excretion urine from administration with oral T, T-gel, dihydrotestosterone (DHT) - gel and dehydroepiandrosterone (DHEA). Results indicated the importance of both androstanediols as important IRMS markers where relative values compared to an ERC (Δδ(13)C) yielded better detection accuracy than absolute δ(13)C-values. The detection times of all administered endogenous steroids were evaluated using the proposed thresholds. The results of traditional steroid profiling and a new approach based upon minor steroid metabolites monitoring introduced in a longitudinal framework were evaluated with IRMS. With traditional steroid profiling methods, 95% of the atypical samples could be confirmed whereas an additional 74% of IRMS confirmed was provided by a new biomarkers strategy. These results prove that the other steroid profiling strategies can improve the efficiency in detection of misuse with endogenous steroids. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. New method of extracting information of arterial oxygen saturation based on ∑ | 𝚫 |

    NASA Astrophysics Data System (ADS)

    Dai, Wenting; Lin, Ling; Li, Gang

    2017-04-01

    Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.

  1. New method of extracting information of arterial oxygen saturation based on ∑|𝚫 |

    NASA Astrophysics Data System (ADS)

    Wenting, Dai; Ling, Lin; Gang, Li

    2017-04-01

    Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.

  2. An experimental loop design for the detection of constitutional chromosomal aberrations by array CGH

    PubMed Central

    2009-01-01

    Background Comparative genomic hybridization microarrays for the detection of constitutional chromosomal aberrations is the application of microarray technology coming fastest into routine clinical application. Through genotype-phenotype association, it is also an important technique towards the discovery of disease causing genes and genomewide functional annotation in human. When using a two-channel microarray of genomic DNA probes for array CGH, the basic setup consists in hybridizing a patient against a normal reference sample. Two major disadvantages of this setup are (1) the use of half of the resources to measure a (little informative) reference sample and (2) the possibility that deviating signals are caused by benign copy number variation in the "normal" reference instead of a patient aberration. Instead, we apply an experimental loop design that compares three patients in three hybridizations. Results We develop and compare two statistical methods (linear models of log ratios and mixed models of absolute measurements). In an analysis of 27 patients seen at our genetics center, we observed that the linear models of the log ratios are advantageous over the mixed models of the absolute intensities. Conclusion The loop design and the performance of the statistical analysis contribute to the quick adoption of array CGH as a routine diagnostic tool. They lower the detection limit of mosaicisms and improve the assignment of copy number variation for genetic association studies. PMID:19925645

  3. Automatic assessment of functional health decline in older adults based on smart home data.

    PubMed

    Alberdi Aramendi, Ane; Weakley, Alyssa; Aztiria Goenaga, Asier; Schmitter-Edgecombe, Maureen; Cook, Diane J

    2018-05-01

    In the context of an aging population, tools to help elderly to live independently must be developed. The goal of this paper is to evaluate the possibility of using unobtrusively collected activity-aware smart home behavioral data to automatically detect one of the most common consequences of aging: functional health decline. After gathering the longitudinal smart home data of 29 older adults for an average of >2 years, we automatically labeled the data with corresponding activity classes and extracted time-series statistics containing 10 behavioral features. Using this data, we created regression models to predict absolute and standardized functional health scores, as well as classification models to detect reliable absolute change and positive and negative fluctuations in everyday functioning. Functional health was assessed every six months by means of the Instrumental Activities of Daily Living-Compensation (IADL-C) scale. Results show that total IADL-C score and subscores can be predicted by means of activity-aware smart home data, as well as a reliable change in these scores. Positive and negative fluctuations in everyday functioning are harder to detect using in-home behavioral data, yet changes in social skills have shown to be predictable. Future work must focus on improving the sensitivity of the presented models and performing an in-depth feature selection to improve overall accuracy. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. A Simulation-Based Study on the Comparison of Statistical and Time Series Forecasting Methods for Early Detection of Infectious Disease Outbreaks.

    PubMed

    Yang, Eunjoo; Park, Hyun Woo; Choi, Yeon Hwa; Kim, Jusim; Munkhdalai, Lkhagvadorj; Musa, Ibrahim; Ryu, Keun Ho

    2018-05-11

    Early detection of infectious disease outbreaks is one of the important and significant issues in syndromic surveillance systems. It helps to provide a rapid epidemiological response and reduce morbidity and mortality. In order to upgrade the current system at the Korea Centers for Disease Control and Prevention (KCDC), a comparative study of state-of-the-art techniques is required. We compared four different temporal outbreak detection algorithms: the CUmulative SUM (CUSUM), the Early Aberration Reporting System (EARS), the autoregressive integrated moving average (ARIMA), and the Holt-Winters algorithm. The comparison was performed based on not only 42 different time series generated taking into account trends, seasonality, and randomly occurring outbreaks, but also real-world daily and weekly data related to diarrhea infection. The algorithms were evaluated using different metrics. These were namely, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), F1 score, symmetric mean absolute percent error (sMAPE), root-mean-square error (RMSE), and mean absolute deviation (MAD). Although the comparison results showed better performance for the EARS C3 method with respect to the other algorithms, despite the characteristics of the underlying time series data, Holt⁻Winters showed better performance when the baseline frequency and the dispersion parameter values were both less than 1.5 and 2, respectively.

  5. An experimental loop design for the detection of constitutional chromosomal aberrations by array CGH.

    PubMed

    Allemeersch, Joke; Van Vooren, Steven; Hannes, Femke; De Moor, Bart; Vermeesch, Joris Robert; Moreau, Yves

    2009-11-19

    Comparative genomic hybridization microarrays for the detection of constitutional chromosomal aberrations is the application of microarray technology coming fastest into routine clinical application. Through genotype-phenotype association, it is also an important technique towards the discovery of disease causing genes and genomewide functional annotation in human. When using a two-channel microarray of genomic DNA probes for array CGH, the basic setup consists in hybridizing a patient against a normal reference sample. Two major disadvantages of this setup are (1) the use of half of the resources to measure a (little informative) reference sample and (2) the possibility that deviating signals are caused by benign copy number variation in the "normal" reference instead of a patient aberration. Instead, we apply an experimental loop design that compares three patients in three hybridizations. We develop and compare two statistical methods (linear models of log ratios and mixed models of absolute measurements). In an analysis of 27 patients seen at our genetics center, we observed that the linear models of the log ratios are advantageous over the mixed models of the absolute intensities. The loop design and the performance of the statistical analysis contribute to the quick adoption of array CGH as a routine diagnostic tool. They lower the detection limit of mosaicisms and improve the assignment of copy number variation for genetic association studies.

  6. Swept Frequency Laser Metrology System

    NASA Technical Reports Server (NTRS)

    Zhao, Feng (Inventor)

    2010-01-01

    A swept frequency laser ranging system having sub-micron accuracy that employs multiple common-path heterodyne interferometers, one coupled to a calibrated delay-line for use as an absolute reference for the ranging system. An exemplary embodiment uses two laser heterodyne interferometers to create two laser beams at two different frequencies to measure distance and motions of target(s). Heterodyne fringes generated from reflections off a reference fiducial X(sub R) and measurement (or target) fiducial X(sub M) are reflected back and are then detected by photodiodes. The measured phase changes Delta phi(sub R) and Delta phi (sub m) resulting from the laser frequency swept gives target position. The reference delay-line is the only absolute reference needed in the metrology system and this provides an ultra-stable reference and simple/economical system.

  7. Separation and determination of molybdenum by inductively coupled plasma optical emission spectrometry using quercetin immobilization on silica gel

    NASA Astrophysics Data System (ADS)

    Azeredo, Laerte C.; Azeredo, Maria Aparecida A.; Castro, Rosane N.; Saldanha, Marcelo Francisco C.; Perez, Daniel V.

    2002-12-01

    A new method is described for the separation of molybdenum based on its chelation in a column packed with quercetin, immobilized on silica gel in a slightly acidic medium (pH 5.0). Recovery ranged from 95% (NIST 1515 apple leaves) to 99% (deionized, distilled water; DDW) with an absolute blank of 27.5±1.6 pg obtained for the analysis of DDW. Detection limits, absolute and relative, based on a 5.0-ml sample volume were 4.8 pg and 1 ng l -1, respectively. Results are presented for molybdenum determination in two standard reference materials, NIST 1515 and NIST 1547 peach leaves, using simple calibration curves for quantification. α-Benzoinoxime was used as the eluent.

  8. Reduction of User Interaction by Autonomy

    NASA Technical Reports Server (NTRS)

    Morfopoulos, Arin; McHenry, Michael; Matthies, Larry

    2006-01-01

    This paper describes experiments that quantify the improvement that autonomous behaviors enable in the amount of user interaction required to navigate a robot in urban environments. Many papers have discussed various ways to measure the absolute level of autonomy of a system; we measured the relative improvement of autonomous behaviors over teleoperation across multiple traverses of the same course. We performed four runs each on an 'easy' course and a 'hard' course, where half the runs were teleoperated and half used more autonomous behaviors. Statistics show 40-70% reductions in the amount of time the user interacts with the control station; however, with the behaviors tested, user attention remained on the control station even when he was not interacting. Reducing the need for attention will require better obstacle detection and avoidance and better absolute position estimation.

  9. Enabling High Efficiency Nanoplasmonics with Novel Nanoantenna Architectures

    PubMed Central

    Cohen, Moshik; Shavit, Reuven; Zalevsky, Zeev

    2015-01-01

    Surface plasmon polaritons (SPPs) are propagating excitations that arise from coupling of light with collective electron oscillations. Characterized by high field intensity and nanometric dimensions, SPPs fashion rapid expansion of interest from fundamental and applicative perspectives. However, high metallic losses at optical frequencies still make nanoplasmonics impractical when high absolute efficiency is paramount, with major challenge is efficient plasmon generation in deep nanoscale. Here we introduce the Plantenna, the first reported nanodevice with the potential of addressing these limitations utilizing novel plasmonic architecture. The Plantenna has simple 2D structure, ultracompact dimensions and is fabricated on Silicon chip for future CMOS integration. We design the Plantenna to feed channel (20 nm × 20 nm) nanoplasmonic waveguides, achieving 52% coupling efficiency with Plantenna dimensions of λ3/17,000. We theoretically and experimentally show that the Plantenna enormously outperforms dipole couplers, achieving 28 dB higher efficiency with broad polarization diversity and huge local field enhancement. Our findings confirm the Plantenna as enabling device for high efficiency plasmonic technologies such as quantum nanoplasmonics, molecular strong coupling and plasmon nanolasers. PMID:26620270

  10. Anticipatory flexibility: larval population density in moths determines male investment in antennae, wings and testes.

    PubMed

    Johnson, Tamara L; Symonds, Matthew R E; Elgar, Mark A

    2017-11-15

    Developmental plasticity provides individuals with a distinct advantage when the reproductive environment changes dramatically. Variation in population density, in particular, can have profound effects on male reproductive success. Females may be easier to locate in dense populations, but there may be a greater risk of sperm competition. Thus, males should invest in traits that enhance fertilization success over traits that enhance mate location. Conversely, males in less dense populations should invest more in structures that will facilitate mate location. In Lepidoptera, this may result in the development of larger antennae to increase the likelihood of detecting female sex pheromones, and larger wings to fly more efficiently. We explored the effects of larval density on adult morphology in the gum-leaf skeletonizer moth, Uraba lugens , by manipulating both the number of larvae and the size of the rearing container. This experimental arrangement allowed us to reveal the cues used by larvae to assess whether absolute number or density influences adult responses. Male investment in testes size depended on the number of individuals, while male investment in wings and antennae depended upon larval density. By contrast, the size of female antennae and wings were influenced by an interaction of larval number and container size. This study demonstrates that male larvae are sensitive to cues that may reveal adult population density, and adjust investment in traits associated with fertilization success and mate detection accordingly. © 2017 The Author(s).

  11. Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon

    NASA Astrophysics Data System (ADS)

    Neves, F.; Lindote, A.; Morozov, A.; Solovov, V.; Silva, C.; Bras, P.; Rodrigues, J. P.; Lopes, M. I.

    2017-01-01

    The performance of a detector using liquid xenon (LXe) as a scintillator is strongly dependent on the collection efficiency for xenon scintillation light, which in turn is critically dependent on the reflectance of the surfaces that surround the active volume. To improve the light collection in such detectors the active volume is usually surrounded by polytetrafluoroethylene (PTFE) reflector panels, used due to its very high reflectance—even at the short wavelength of scintillation light of LXe (peaked at 178 nm). In this work, which contributed to the overall R&D effort towards the LUX-ZEPLIN (LZ) experiment, we present experimental results for the absolute reflectance measurements of three different PTFE samples (including the material used in the LUX detector) immersed in LXe for its scintillation light. The obtained results show that very high bi-hemispherical reflectance values (>= 97%) can be achieved, enabling very low energy thresholds in liquid xenon scintillator-based detectors.

  12. Comparison of methods for developing the dynamics of rigid-body systems

    NASA Technical Reports Server (NTRS)

    Ju, M. S.; Mansour, J. M.

    1989-01-01

    Several approaches for developing the equations of motion for a three-degree-of-freedom PUMA robot were compared on the basis of computational efficiency (i.e., the number of additions, subtractions, multiplications, and divisions). Of particular interest was the investigation of the use of computer algebra as a tool for developing the equations of motion. Three approaches were implemented algebraically: Lagrange's method, Kane's method, and Wittenburg's method. Each formulation was developed in absolute and relative coordinates. These six cases were compared to each other and to a recursive numerical formulation. The results showed that all of the formulations implemented algebraically required fewer calculations than the recursive numerical algorithm. The algebraic formulations required fewer calculations in absolute coordinates than in relative coordinates. Each of the algebraic formulations could be simplified, using patterns from Kane's method, to yield the same number of calculations in a given coordinate system.

  13. Using DNA origami nanostructures to determine absolute cross sections for UV photon-induced DNA strand breakage.

    PubMed

    Vogel, Stefanie; Rackwitz, Jenny; Schürman, Robin; Prinz, Julia; Milosavljević, Aleksandar R; Réfrégiers, Matthieu; Giuliani, Alexandre; Bald, Ilko

    2015-11-19

    We have characterized ultraviolet (UV) photon-induced DNA strand break processes by determination of absolute cross sections for photoabsorption and for sequence-specific DNA single strand breakage induced by photons in an energy range from 6.50 to 8.94 eV. These represent the lowest-energy photons able to induce DNA strand breaks. Oligonucleotide targets are immobilized on a UV transparent substrate in controlled quantities through attachment to DNA origami templates. Photon-induced dissociation of single DNA strands is visualized and quantified using atomic force microscopy. The obtained quantum yields for strand breakage vary between 0.06 and 0.5, indicating highly efficient DNA strand breakage by UV photons, which is clearly dependent on the photon energy. Above the ionization threshold strand breakage becomes clearly the dominant form of DNA radiation damage, which is then also dependent on the nucleotide sequence.

  14. Examining robustness of model selection with half-normal and LASSO plots for unreplicated factorial designs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jang, Dae -Heung; Anderson-Cook, Christine Michaela

    When there are constraints on resources, an unreplicated factorial or fractional factorial design can allow efficient exploration of numerous factor and interaction effects. A half-normal plot is a common graphical tool used to compare the relative magnitude of effects and to identify important effects from these experiments when no estimate of error from the experiment is available. An alternative is to use a least absolute shrinkage and selection operation plot to examine the pattern of model selection terms from an experiment. We examine how both the half-normal and least absolute shrinkage and selection operation plots are impacted by the absencemore » of individual observations or an outlier, and the robustness of conclusions obtained from these 2 techniques for identifying important effects from factorial experiments. As a result, the methods are illustrated with 2 examples from the literature.« less

  15. Molecular spectroscopy for producing ultracold ground-state NaRb molecules

    NASA Astrophysics Data System (ADS)

    Wang, Dajun; Guo, Mingyang; Zhu, Bing; Lu, Bo; Ye, Xin; Wang, Fudong; Vexiau, Romain; Bouloufa-Maafa, Nadia; Quéméner, Goulven; Dulieu, Olivier

    2016-05-01

    Recently, we have successfully created an ultracold sample of absolute ground-state NaRb molecules by two-photon Raman transfer of weakly bound Feshbach molecules. Here we will present the detailed spectroscopic investigations on both the excited and the rovibrational ground states for finding the two-photon path. For the excited state, we focus on the A1Σ+ /b3 Π singlet and triplet admixture. We discovered an anomalously strong coupling between the Ω =0+ and 0- components which renders efficient population transfer possible. In the ground state, the pure nuclear hyperfine levels have been clearly resolved, which allows us to create molecules in the absolute ground state directly with Raman transfer. This work is jointly supported by Agence Nationale de la Recherche (#ANR-13- IS04-0004-01) and Hong Kong Research Grant Council (#A-CUHK403/13) through the COPOMOL project.

  16. Examining robustness of model selection with half-normal and LASSO plots for unreplicated factorial designs

    DOE PAGES

    Jang, Dae -Heung; Anderson-Cook, Christine Michaela

    2017-04-12

    When there are constraints on resources, an unreplicated factorial or fractional factorial design can allow efficient exploration of numerous factor and interaction effects. A half-normal plot is a common graphical tool used to compare the relative magnitude of effects and to identify important effects from these experiments when no estimate of error from the experiment is available. An alternative is to use a least absolute shrinkage and selection operation plot to examine the pattern of model selection terms from an experiment. We examine how both the half-normal and least absolute shrinkage and selection operation plots are impacted by the absencemore » of individual observations or an outlier, and the robustness of conclusions obtained from these 2 techniques for identifying important effects from factorial experiments. As a result, the methods are illustrated with 2 examples from the literature.« less

  17. The NIST Detector-Based Luminous Intensity Scale

    PubMed Central

    Cromer, C. L.; Eppeldauer, G.; Hardis, J. E.; Larason, T. C.; Ohno, Y.; Parr, A. C.

    1996-01-01

    The Système International des Unités (SI) base unit for photometry, the candela, has been realized by using absolute detectors rather than absolute sources. This change in method permits luminous intensity calibrations of standard lamps to be carried out with a relative expanded uncertainty (coverage factor k = 2, and thus a 2 standard deviation estimate) of 0.46 %, almost a factor-of-two improvement. A group of eight reference photometers has been constructed with silicon photodiodes, matched with filters to mimic the spectral luminous efficiency function for photopic vision. The wide dynamic range of the photometers aid in their calibration. The components of the photometers were carefully measured and selected to reduce the sources of error and to provide baseline data for aging studies. Periodic remeasurement of the photometers indicate that a yearly recalibration is required. The design, characterization, calibration, evaluation, and application of the photometers are discussed. PMID:27805119

  18. Neutron skyshine from intense 14-MeV neutron source facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, T.; Hayashi, K.; Takahashi, A.

    1985-07-01

    The dose distribution and the spectrum variation of neutrons due to the skyshine effect have been measured with the high-efficiency rem counter, the multisphere spectrometer, and the NE-213 scintillator in the environment surrounding an intense 14-MeV neutron source facility. The dose distribution and the energy spectra of neutrons around the facility used as a skyshine source have also been measured to enable the absolute evaluation of the skyshine effect. The skyshine effect was analyzed by two multigroup Monte Carlo codes, NIMSAC and MMCR-2, by two discrete ordinates S /sub n/ codes, ANISN and DOT3.5, and by the shield structure designmore » code for skyshine, SKYSHINE-II. The calculated results show good agreement with the measured results in absolute values. These experimental results should be useful as benchmark data for shyshine analysis and for shielding design of fusion facilities.« less

  19. Technical Note: scuda: A software platform for cumulative dose assessment.

    PubMed

    Park, Seyoun; McNutt, Todd; Plishker, William; Quon, Harry; Wong, John; Shekhar, Raj; Lee, Junghoon

    2016-10-01

    Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (scuda) that can be seamlessly integrated into the clinical workflow. scuda consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.

  20. Technical Note: SCUDA: A software platform for cumulative dose assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Seyoun; McNutt, Todd; Quon, Harry

    Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our imagemore » PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.« less

Top