Drift Reduction in Pedestrian Navigation System by Exploiting Motion Constraints and Magnetic Field.
Ilyas, Muhammad; Cho, Kuk; Baeg, Seung-Ho; Park, Sangdeok
2016-09-09
Pedestrian navigation systems (PNS) using foot-mounted MEMS inertial sensors use zero-velocity updates (ZUPTs) to reduce drift in navigation solutions and estimate inertial sensor errors. However, it is well known that ZUPTs cannot reduce all errors, especially as heading error is not observable. Hence, the position estimates tend to drift and even cyclic ZUPTs are applied in updated steps of the Extended Kalman Filter (EKF). This urges the use of other motion constraints for pedestrian gait and any other valuable heading reduction information that is available. In this paper, we exploit two more motion constraints scenarios of pedestrian gait: (1) walking along straight paths; (2) standing still for a long time. It is observed that these motion constraints (called "virtual sensor"), though considerably reducing drift in PNS, still need an absolute heading reference. One common absolute heading estimation sensor is the magnetometer, which senses the Earth's magnetic field and, hence, the true heading angle can be calculated. However, magnetometers are susceptible to magnetic distortions, especially in indoor environments. In this work, an algorithm, called magnetic anomaly detection (MAD) and compensation is designed by incorporating only healthy magnetometer data in the EKF updating step, to reduce drift in zero-velocity updated INS. Experiments are conducted in GPS-denied and magnetically distorted environments to validate the proposed algorithms.
Drift Reduction in Pedestrian Navigation System by Exploiting Motion Constraints and Magnetic Field
Ilyas, Muhammad; Cho, Kuk; Baeg, Seung-Ho; Park, Sangdeok
2016-01-01
Pedestrian navigation systems (PNS) using foot-mounted MEMS inertial sensors use zero-velocity updates (ZUPTs) to reduce drift in navigation solutions and estimate inertial sensor errors. However, it is well known that ZUPTs cannot reduce all errors, especially as heading error is not observable. Hence, the position estimates tend to drift and even cyclic ZUPTs are applied in updated steps of the Extended Kalman Filter (EKF). This urges the use of other motion constraints for pedestrian gait and any other valuable heading reduction information that is available. In this paper, we exploit two more motion constraints scenarios of pedestrian gait: (1) walking along straight paths; (2) standing still for a long time. It is observed that these motion constraints (called “virtual sensor”), though considerably reducing drift in PNS, still need an absolute heading reference. One common absolute heading estimation sensor is the magnetometer, which senses the Earth’s magnetic field and, hence, the true heading angle can be calculated. However, magnetometers are susceptible to magnetic distortions, especially in indoor environments. In this work, an algorithm, called magnetic anomaly detection (MAD) and compensation is designed by incorporating only healthy magnetometer data in the EKF updating step, to reduce drift in zero-velocity updated INS. Experiments are conducted in GPS-denied and magnetically distorted environments to validate the proposed algorithms. PMID:27618056
Rohde, Max; Nielsen, Anne L; Johansen, Jørgen; Sørensen, Jens A; Nguyen, Nina; Diaz, Anabel; Nielsen, Mie K; Asmussen, Jon T; Christiansen, Janus M; Gerke, Oke; Thomassen, Anders; Alavi, Abass; Høilund-Carlsen, Poul Flemming; Godballe, Christian
2017-12-01
The purpose of this study was to determine the detection rate of distant metastasis and synchronous cancer, comparing clinically used imaging strategies based on chest x-ray + head and neck MRI (CXR/MRI) and chest CT + head and neck MRI (CHCT/MRI) with 18 F-FDG PET/CT upfront in the diagnostic workup of patients with oral, pharyngeal, or laryngeal cancer. Methods: This was a prospective cohort study based on paired data. Consecutive patients with histologically verified primary head and squamous cell carcinoma at Odense University Hospital from September 2013 to March 2016 were considered for the study. Included patients underwent CXR/MRI and CHCT/MRI as well as PET/CT on the same day and before biopsy. Scans were read masked by separate teams of experienced nuclear physicians or radiologists. The true detection rate of distant metastasis and synchronous cancer was assessed for CXR/MRI, CHCT/MRI, and PET/CT. Results: A total of 307 patients were included. CXR/MRI correctly detected 3 (1%) patients with distant metastasis, CHCT/MRI detected 11 (4%) patients, and PET/CT detected 18 (6%) patients. The absolute differences of 5% and 2%, respectively, were statistically significant in favor of PET/CT. Also, PET/CT correctly detected 25 (8%) synchronous cancers, which was significantly more than CXR/MRI (3 patients, 1%) and CHCT/MRI (6 patients, 2%). The true detection rate of distant metastasis or synchronous cancer with PET/CT was 13% (40 patients), which was significantly higher than 2% (6 patients) for CXR/MRI and 6% (17 patients) for CHCT/MRI. Conclusion: A clinical imaging strategy based on PET/CT demonstrated a significantly higher detection rate of distant metastasis or synchronous cancer than strategies in current clinical imaging guidelines, of which European ones primarily recommend CXR/MRI, whereas U.S. guidelines preferably point to CHCT/MRI in patients with head and neck squamous cell carcinoma. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
van Ginkel, Joost H; Huibers, Manon M H; van Es, Robert J J; de Bree, Remco; Willems, Stefan M
2017-06-19
During posttreatment surveillance of head and neck cancer patients, imaging is insufficiently accurate for the early detection of relapsing disease. Free circulating tumor DNA (ctDNA) may serve as a novel biomarker for monitoring tumor burden during posttreatment surveillance of these patients. In this exploratory study, we investigated whether low level ctDNA in plasma of head and neck cancer patients can be detected using Droplet Digital PCR (ddPCR). TP53 mutations were determined in surgically resected primary tumor samples from six patients with high stage (II-IV), moderate to poorly differentiated head and neck squamous cell carcinoma (HNSCC). Subsequently, mutation specific ddPCR assays were designed. Pretreatment plasma samples from these patients were examined on the presence of ctDNA by ddPCR using the mutation-specific assays. The ddPCR results were evaluated alongside clinicopathological data. In all cases, plasma samples were found positive for targeted TP53 mutations in varying degrees (absolute quantification of 2.2-422 mutational copies/ml plasma). Mutations were detected in wild-type TP53 background templates of 7667-156,667 copies/ml plasma, yielding fractional abundances of down to 0.01%. Our results show that detection of tumor specific TP53 mutations in low level ctDNA from HNSCC patients using ddPCR is technically feasible and provide ground for future research on ctDNA quantification for the use of diagnostic biomarkers in the posttreatment surveillance of HNSCC patients.
Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration
NASA Astrophysics Data System (ADS)
Sabet, Mahsheed; Rowshanfarzad, Pejman; Vial, Philip; Menk, Frederick W.; Greer, Peter B.
2012-08-01
In this study an amorphous silicon electronic portal imaging device (a-Si EPID) converted to direct detection configuration was investigated as a transit dosimeter for intensity modulated radiation therapy (IMRT). After calibration to dose and correction for a background offset signal, the EPID-measured absolute IMRT transit doses for 29 fields were compared to a MatriXX two-dimensional array of ionization chambers (as reference) using Gamma evaluation (3%, 3 mm). The MatriXX was first evaluated as reference for transit dosimetry. The accuracy of EPID measurements was also investigated by comparison of point dose measurements by an ionization chamber on the central axis with slab and anthropomorphic phantoms in a range of simple to complex fields. The uncertainty in ionization chamber measurements in IMRT fields was also investigated by its displacement from the central axis and comparison with the central axis measurements. Comparison of the absolute doses measured by the EPID and MatriXX with slab phantoms in IMRT fields showed that on average 96.4% and 97.5% of points had a Gamma index<1 in head and neck and prostate fields, respectively. For absolute dose comparisons with anthropomorphic phantoms, the values changed to an average of 93.6%, 93.7% and 94.4% of points with Gamma index<1 in head and neck, brain and prostate fields, respectively. Point doses measured by the EPID and ionization chamber were within 3% difference for all conditions. The deviations introduced in the response of the ionization chamber in IMRT fields were<1%. The direct EPID performance for transit dosimetry showed that it has the potential to perform accurate, efficient and comprehensive in vivo dosimetry for IMRT.
An Orientation Sensor-Based Head Tracking System for Driver Behaviour Monitoring.
Zhao, Yifan; Görne, Lorenz; Yuen, Iek-Man; Cao, Dongpu; Sullman, Mark; Auger, Daniel; Lv, Chen; Wang, Huaji; Matthias, Rebecca; Skrypchuk, Lee; Mouzakitis, Alexandros
2017-11-22
Although at present legislation does not allow drivers in a Level 3 autonomous vehicle to engage in a secondary task, there may become a time when it does. Monitoring the behaviour of drivers engaging in various non-driving activities (NDAs) is crucial to decide how well the driver will be able to take over control of the vehicle. One limitation of the commonly used face-based head tracking system, using cameras, is that sufficient features of the face must be visible, which limits the detectable angle of head movement and thereby measurable NDAs, unless multiple cameras are used. This paper proposes a novel orientation sensor based head tracking system that includes twin devices, one of which measures the movement of the vehicle while the other measures the absolute movement of the head. Measurement error in the shaking and nodding axes were less than 0.4°, while error in the rolling axis was less than 2°. Comparison with a camera-based system, through in-house tests and on-road tests, showed that the main advantage of the proposed system is the ability to detect angles larger than 20° in the shaking and nodding axes. Finally, a case study demonstrated that the measurement of the shaking and nodding angles, produced from the proposed system, can effectively characterise the drivers' behaviour while engaged in the NDAs of chatting to a passenger and playing on a smartphone.
An Orientation Sensor-Based Head Tracking System for Driver Behaviour Monitoring
Görne, Lorenz; Yuen, Iek-Man; Cao, Dongpu; Sullman, Mark; Auger, Daniel; Lv, Chen; Wang, Huaji; Matthias, Rebecca; Skrypchuk, Lee; Mouzakitis, Alexandros
2017-01-01
Although at present legislation does not allow drivers in a Level 3 autonomous vehicle to engage in a secondary task, there may become a time when it does. Monitoring the behaviour of drivers engaging in various non-driving activities (NDAs) is crucial to decide how well the driver will be able to take over control of the vehicle. One limitation of the commonly used face-based head tracking system, using cameras, is that sufficient features of the face must be visible, which limits the detectable angle of head movement and thereby measurable NDAs, unless multiple cameras are used. This paper proposes a novel orientation sensor based head tracking system that includes twin devices, one of which measures the movement of the vehicle while the other measures the absolute movement of the head. Measurement error in the shaking and nodding axes were less than 0.4°, while error in the rolling axis was less than 2°. Comparison with a camera-based system, through in-house tests and on-road tests, showed that the main advantage of the proposed system is the ability to detect angles larger than 20° in the shaking and nodding axes. Finally, a case study demonstrated that the measurement of the shaking and nodding angles, produced from the proposed system, can effectively characterise the drivers’ behaviour while engaged in the NDAs of chatting to a passenger and playing on a smartphone. PMID:29165331
NASA Astrophysics Data System (ADS)
Dekdouk, B.; Ktistis, C.; Armitage, D. W.; Peyton, A. J.
2010-04-01
Magnetic induction tomography (MIT) has been proposed as a possible method for imaging stroke in the human brain. Hemorrhagic stroke is characterized by local blood accumulation in the brain and exhibits a greater change in conductivity with frequency compared to other tissues which is observed in the frequency range of interest [1-10] MHz. In this study, we investigate the feasibility of detecting hemorrhagic stroke using absolute and frequency difference imaging. For this purpose, a model of the head originally obtained from MRI and X-ray data was used, to which a large stroke (50 ml) was added. In addition, a model of a 16 channel circular array MIT system was employed. The received coil induced voltages were computed using a custom eddy current solver, based on the finite difference method. For absolute imaging, the induced voltages at the receiver coils were calculated from various coil combinations at 10 MHz frequency together with anticipated systematic errors and biases (orientation and displacement of the coils, movement of the head). The induced voltage noise due to these systematic inaccuracies was compared with the voltage change due to the stroke. In order to decrease the impact of this noise, frequency difference was also considered, whereby measurements were performed at another frequency (1MHz) and subtracted. Comparison results are presented and a realistic picture is delivered with to regard the required mechanical stability and electronics accuracy for this particular medical application
Delineation of sympatric morphotypes of lake trout in Lake Superior
Moore, Seth A.; Bronte, Charles R.
2001-01-01
Three morphotypes of lake trout Salvelinus namaycush are recognized in Lake Superior: lean, siscowet, and humper. Absolute morphotype assignment can be difficult. We used a size-free, whole-body morphometric analysis (truss protocol) to determine whether differences in body shape existed among lake trout morphotypes. Our results showed discrimination where traditional morphometric characters and meristic measurements failed to detect differences. Principal components analysis revealed some separation of all three morphotypes based on head and caudal peduncle shape, but it also indicated considerable overlap in score values. Humper lake trout have smaller caudal peduncle widths to head length and depth characters than do lean or siscowet lake trout. Lean lake trout had larger head measures to caudal widths, whereas siscowet had higher caudal peduncle to head measures. Backward stepwise discriminant function analysis retained two head measures, three midbody measures, and four caudal peduncle measures; correct classification rates when using these variables were 83% for leans, 80% for siscowets, and 83% for humpers, which suggests the measures we used for initial classification were consistent. Although clear ecological reasons for these differences are not readily apparent, patterns in misclassification rates may be consistent with evolutionary hypotheses for lake trout within the Laurentian Great Lakes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saenz, D; Gutierrez, A
Purpose: The ScandiDos Discover has obtained FDA clearance and is now clinically released. We studied the essential attenuation and beam hardening components as well as tested the diode array’s ability to detect changes in absolute dose and MLC leaf positions. Methods: The ScandiDos Discover was mounted on the heads of an Elekta VersaHD and a Varian 23EX. Beam attenuation measurements were made at 10 cm depth for 6 MV and 18 MV beam energies. The PDD(10) was measured as a metric for the effect on beam quality. Next, a plan consisting of two orthogonal 10 × 10 cm2 fields wasmore » used to adjust the dose per fraction by scaling monitor units to test the absolute dose detection sensitivity of the Discover. A second plan (conformal arc) was then delivered several times independently on the Elekta VersaHD. Artificially introduced MLC position errors in the four central leaves were then added. The errors were incrementally increased from 1 mm to 4 mm and back across seven control points. Results: The absolute dose measured at 10 cm depth decreased by 1.2% and 0.7% for 6 MV and 18 MV beam with the Discover, respectively. Attenuation depended slightly on the field size but only changed the attenuation by 0.1% across 5 × 5 cm{sup 2} and 20 − 20 cm{sup 2} fields. The change in PDD(10) for a 10 − 10 cm{sup 2} field was +0.1% and +0.6% for 6 MV and 18 MV, respectively. Changes in monitor units from −5.0% to 5.0% were faithfully detected. Detected leaf errors were within 1.0 mm of intended errors. Conclusion: A novel in-vivo dosimeter monitoring the radiation beam during treatment was examined through its attenuation and beam hardening characteristics. The device tracked with changes in absolute dose as well as introduced leaf position deviations.« less
Feedback dew-point sensor utilizing optimally cut plastic optical fibres
NASA Astrophysics Data System (ADS)
Hadjiloucas, S.; Irvine, J.; Keating, D. A.
2000-01-01
A plastic optical fibre reflectance sensor that makes full use of the critical angle of the fibres is implemented to monitor dew formation on a Peltier-cooled reflector surface. The optical configuration permits isolation of optoelectronic components from the sensing head and better light coupling between the reflector and the detecting fibre, giving a better signal of the onset of dew formation on the reflector. Continuous monitoring of the rate of change in reflectance as well as the absolute reflectance signals, the use of a novel polymethyl-methacrylate-coated hydrophobic film reflector on the Peltier element and the application of feedback around the point of dew formation, further reduces the possibility of contamination of the sensor head. Under closed-loop operation, the sensor is capable of cycling around the point of dew formation at a frequency of 2.5 Hz.
Brahem, Sonia; Elghezal, Hatem; Ghédir, Houda; Landolsi, Hanène; Amara, Abdelbacett; Ibala, Samira; Gribaa, Moez; Saad, Ali; Mehdi, Meriem
2011-12-01
To compare the results of cytogenetic and molecular analysis between absolute polymorphic and monomorphic teratozoospermia. The semen samples from patients with polymorphic teratozoospermia (n = 20), globozoospermia (n = 8), or macrocephalic sperm head syndrome (n = 12), and healthy fertile men (n = 20) were analyzed according to the World Health Organization criteria. The constitutional blood karyotype of the patients was performed on cultured lymphocytes, according to standard techniques. Microdeletion analysis of the Y chromosomes used a sequence tagged site-polymerase chain reaction technique. Triple-color fluorescent in situ hybridization for chromosomes X, Y, and 18 were used to analyze the meiotic segregation. DNA fragmentation was detected using the terminal desoxynucleotidyl transferase-mediated deoxyuridine triphosphate biotin nick-end labeling assay. Whatever the type of teratozoospermia, a normal karyotype and an absence of Y chromosome microdeletion were shown for all patients. A significant increase in the sperm aneuploidy rate and DNA fragmentation were shown, regardless of the type of teratozoospermia. Spermatozoa of the patients with globozoospermia carry an abnormal chromosomal constitution and DNA damage rate with the same frequency as that found in the sperm of patients with absolute polymorphic teratozoospermia. However, a greater sperm aneuploidy rate and DNA fragmentation were found in patients whose teratozoospermia was mainly characterized by increased rates of spermatozoa with macrocephalic head and multiple flagella. Our data have demonstrated that DNA fragmentation and sperm aneuploidy are critical tests in teratozoospermic men, because the results could negatively affect the intracytoplasmic sperm injection outcomes and might play an important role in the counseling of couples considering intracytoplasmic sperm injection. Copyright © 2011 Elsevier Inc. All rights reserved.
Femoral head asymmetry and coxa magna: anatomic study.
Young, Ernest Y; Gebhart, Jeremy J; Bajwa, Navkirat; Cooperman, Daniel R; Ahn, Nicholas U
2014-06-01
Coxa magna, the asymmetrical circumferential enlargement of the femoral head, is an important sequela of pediatric disorders such as Legg-Calvé-Perthes disease. Definitions vary because of lack of controls and a scarcity of research on the distribution of the femoral head asymmetry. This study aims at defining the normal distribution of asymmetry between the left and the right femoral head and neck in the population and how demographics affect these properties. The study also looked at the distribution of side dominance (left or right). This study measured 230 paired femurs from individuals (20 to 40 y old) distributed for sex and ethnicity. The height and weight of the individuals were also recorded. The femoral head diameter and minimal femoral neck diameter in the anteroposterior view were measured on each paired femurs. The absolute and percent differences were determined to define asymmetry. Most of the population fell within 3% of asymmetry for the femoral head and 4% for the femoral neck. The maximum head percent asymmetry was 7.4%. Absolute difference in millimeters to percent asymmetry showed a ratio of 2:1 for the femoral head and 3:1 for the femoral neck. African Americans showed greater femoral head symmetry and a bias toward left-sided femoral head and neck enlargement when compared with their white counterparts. There was a high degree of symmetry between the left and right femoral heads and necks, which supports definitions found in the literature that define coxa magna above 10%. This study defines asymmetry in the femoral head in the normal population, which will help to define a quantitative definition of coxa magna.
Wang, Y A; Zheng, J W; Zhu, H G; Ye, W M; He, Y; Zhang, Z Y
2010-06-01
Venous malformation (VM) is the most common symptomatic low-flow vascular malformation, which predominantly occurs in the head and neck region. The aim of this paper was to evaluate the results of endovascular sclerotherapy of voluminous VM, when the lesion is either >or=15 cm in maximum diameter or the lesion invades more than one anatomical space, in the head and neck region using absolute ethanol under digital subtraction angiography (DSA) guidance. A total of 23 patients with head and neck VMs between October 2005 and December 2008 were retrospectively reviewed. All patients received direct puncture ethanol sclerotherapy under DSA guidance. Follow-up assessments were performed at 3-25 months after therapies were completed, and complications were reported in some cases. All patients were satisfied with the results of therapy. Seventeen patients (73.9%) achieved excellent responses and six patients (26.1%) achieved good responses in magnetic resonance imaging assessments. Minor complications developed during the procedures, all of which were successfully managed with full recovery during follow-ups. Serious complications such as acute pulmonary hypertension, cardiovascular collapse and pulmonary embolism were not encountered. It is concluded that sclerotherapy with absolute ethanol under DSA guidance is an important alternative therapy for voluminous and extensive VM, as the procedure is reasonably safe and offers good therapeutic results.
Results of the first continuous meteor head echo survey at polar latitudes
NASA Astrophysics Data System (ADS)
Schult, Carsten; Stober, Gunter; Janches, Diego; Chau, Jorge L.
2017-11-01
We present the first quasi continuous meteor head echo measurements obtained during a period of over two years using the Middle Atmosphere ALOMAR Radar System (MAARSY). The measurements yield information on the altitude, trajectory, vector velocity, radar cross section, deceleration and dynamical mass of every single event. The large statistical amount of nearly one million meteor head detections provide an excellent overview of the elevation, altitude, velocity and daily count rate distributions during different times of the year at polar latitudes. Only 40% of the meteors were detected within the full width half maximum of the specific sporadic meteor sources. Our observation of the sporadic meteors are compared to the observations with other radar systems and a meteor input function (MIF). The best way to compare different radar systems is by comparing the radar cross section (RCS), which is the main detection criterion for each system. In this study we aim to compare our observations with a MIF, which provides information only about the meteoroid mass. Thus, we are using a statistical approach for the elevation and velocity dependent visibility and a specific mass selection. The predicted absolute count rates from the MIF are in a good agreement with the observation when it is assumed that the radar system is only sensitive to meteoroids with masses higher than one microgram. The analysis of the dynamic masses seems to be consistent with this assumption since the count rate of events with smaller masses are low and decrease even more by using events with relatively small errors.
On the accuracy of the Head Impact Telemetry (HIT) System used in football helmets.
Jadischke, Ron; Viano, David C; Dau, Nathan; King, Albert I; McCarthy, Joe
2013-09-03
On-field measurement of head impacts has relied on the Head Impact Telemetry (HIT) System, which uses helmet mounted accelerometers to determine linear and angular head accelerations. HIT is used in youth and collegiate football to assess the frequency and severity of helmet impacts. This paper evaluates the accuracy of HIT for individual head impacts. Most HIT validations used a medium helmet on a Hybrid III head. However, the appropriate helmet is large based on the Hybrid III head circumference (58 cm) and manufacturer's fitting instructions. An instrumented skull cap was used to measure the pressure between the head of football players (n=63) and their helmet. The average pressure with a large helmet on the Hybrid III was comparable to the average pressure from helmets used by players. A medium helmet on the Hybrid III produced average pressures greater than the 99th percentile volunteer pressure level. Linear impactor tests were conducted using a large and medium helmet on the Hybrid III. Testing was conducted by two independent laboratories. HIT data were compared to data from the Hybrid III equipped with a 3-2-2-2 accelerometer array. The absolute and root mean square error (RMSE) for HIT were computed for each impact (n=90). Fifty-five percent (n=49) had an absolute error greater than 15% while the RMSE was 59.1% for peak linear acceleration. Copyright © 2013 Elsevier Ltd. All rights reserved.
Task-dependent color discrimination
NASA Technical Reports Server (NTRS)
Poirson, Allen B.; Wandell, Brian A.
1990-01-01
When color video displays are used in time-critical applications (e.g., head-up displays, video control panels), the observer must discriminate among briefly presented targets seen within a complex spatial scene. Color-discrimination threshold are compared by using two tasks. In one task the observer makes color matches between two halves of a continuously displayed bipartite field. In a second task the observer detects a color target in a set of briefly presented objects. The data from both tasks are well summarized by ellipsoidal isosensitivity contours. The fitted ellipsoids differ both in their size, which indicates an absolute sensitivity difference, and orientation, which indicates a relative sensitivity difference.
Knox, Joanna Joy; Beilstein, Darren Jay; Charles, Scott Darren; Aarseth, Geir Arne; Rayar, Shivanthi; Treleaven, Julia; Hodges, Paul William
2006-01-01
It has been shown that perception of elbow joint position is affected by changes in head and neck position. Further, people with whiplash-associated disorders (WAD) present with deficits in upper limb coordination and movement. This study is aimed to determine whether the effect of changes in head position on elbow joint position error (JPE) is more pronounced in people with WAD, and to determine whether this is related to the participant's pain and anxiety levels. Nine people with chronic and disabling WAD and 11 healthy people participated in this experiment. The ability to reproduce a position at the elbow joint was assessed after changes in the position of the head and neck to 30 degrees , and with the head in the midline. Pain was monitored in WAD participants. Absolute elbow JPE with the head in neutral was not different between WAD and control participants (P=0.5). Changes in the head and neck position increased absolute elbow JPE in the WAD group (P<0.05), but did not affect elbow JPE in the control group (P=0.4). There was a connection between pain during testing and the effect of changes in head position on elbow JPE (P<0.05). Elbow JPE is affected by movement of the head and neck, with smaller angles of neck rotation in people with WAD than in healthy individuals. This observation may explain deficits in upper limb coordination in people with WAD, which may be due to the presence of pain or reduced range of motion in this population.
Absolute Risk Aversion and the Returns to Education.
ERIC Educational Resources Information Center
Brunello, Giorgio
2002-01-01
Uses 1995 Italian household income and wealth survey to measure individual absolute risk aversion of 1,583 married Italian male household heads. Uses this measure as an instrument for attained education in a standard-log earnings equation. Finds that the IV estimate of the marginal return to schooling is much higher than the ordinary least squares…
NASA Astrophysics Data System (ADS)
Langousis, Andreas; Kaleris, Vassilios; Xeygeni, Vagia; Magkou, Foteini
2017-04-01
Assessing the availability of groundwater reserves at a regional level, requires accurate and robust hydraulic head estimation at multiple locations of an aquifer. To that extent, one needs groundwater observation networks that can provide sufficient information to estimate the hydraulic head at unobserved locations. The density of such networks is largely influenced by the spatial distribution of the hydraulic conductivity in the aquifer, and it is usually determined through trial-and-error, by solving the groundwater flow based on a properly selected set of alternative but physically plausible geologic structures. In this work, we use: 1) dimensional analysis, and b) a pulse-based stochastic model for simulation of synthetic aquifer structures, to calculate the distribution of the absolute error in hydraulic head estimation as a function of the standardized distance from the nearest measuring locations. The resulting distributions are proved to encompass all possible small-scale structural dependencies, exhibiting characteristics (bounds, multi-modal features etc.) that can be explained using simple geometric arguments. The obtained results are promising, pointing towards the direction of establishing design criteria based on large-scale geologic maps.
Clinical applications of correlational vestibular autorotation test.
Hsieh, Li-Chun; Lin, Te-Ming; Chang, Yu-Min; Kuo, Terry B J; Lee, Gho-She
2015-06-01
The correlational vestibular autorotation test (VAT) system has the advantages of good test-retest reliability and calibrations of absolute degrees of eye movement are unnecessary when acquiring a cross correlation coefficient (CCC). The approach is able to efficiently detect peripheral vestibulopathies. A VAT has some drawbacks including poor test-retest reliability and slippage of sensor. This study aimed to develop a correlational VAT system and to evaluate the reliability and applicability of this system. Twenty healthy participants and 10 vertiginous patients were enrolled. Vertical and horizontal autorotations from 0 to 3 Hz with either closed or open eyes were performed. A small sensor and a wireless transmission technique were used to acquire the electro-ocular graph and head velocity signals. The two signals were analyzed using CCCs to assess the functioning of the vestibular ocular reflex (VOR). The results showed a significantly greater CCC for open-eye versus closed-eye of head autorotations. The CCCs also increased significantly with head rotational frequencies. Moreover, the CCCs significantly correlated with the VOR gains at autorotation frequencies ≥1.0 Hz. The test-retest reliability was good (intraclass correlation coefficients ≥0.85). The vertiginous participants had significantly lower individual CCCs and overall average CCC than age- and-gender matched controls.
Sosson, Charlotte; Georges, Carrie; Guillaume, Mathieu; Schuller, Anne-Marie; Schiltz, Christine
2018-01-01
Numbers are thought to be spatially organized along a left-to-right horizontal axis with small/large numbers on its left/right respectively. Behavioral evidence for this mental number line (MNL) comes from studies showing that the reallocation of spatial attention by active left/right head rotation facilitated the generation of small/large numbers respectively. While spatial biases in random number generation (RNG) during active movement are well established in adults, comparable evidence in children is lacking and it remains unclear whether and how children's access to the MNL is affected by active head rotation. To get a better understanding of the development of embodied number processing, we investigated the effect of active head rotation on the mean of generated numbers as well as the mean difference between each number and its immediately preceding response (the first order difference; FOD) not only in adults ( n = 24), but also in 7- to 11-year-old elementary school children ( n = 70). Since the sign and absolute value of FODs carry distinct information regarding spatial attention shifts along the MNL, namely their direction (left/right) and size (narrow/wide) respectively, we additionally assessed the influence of rotation on the total of negative and positive FODs regardless of their numerical values as well as on their absolute values. In line with previous studies, adults produced on average smaller numbers and generated smaller mean FODs during left than right rotation. More concretely, they produced more negative/positive FODs during left/right rotation respectively and the size of negative FODs was larger (in terms of absolute value) during left than right rotation. Importantly, as opposed to adults, no significant differences in RNG between left and right head rotations were observed in children. Potential explanations for such age-related changes in the effect of active head rotation on RNG are discussed. Altogether, the present study confirms that numerical processing is spatially grounded in adults and suggests that its embodied aspect undergoes significant developmental changes.
Landmark-aided localization for air vehicles using learned object detectors
NASA Astrophysics Data System (ADS)
DeAngelo, Mark Patrick
This research presents two methods to localize an aircraft without GPS using fixed landmarks observed from an optical sensor. Onboard absolute localization is useful for vehicle navigation free from an external network. The objective is to achieve practical navigation performance using available autopilot hardware and a downward pointing camera. The first method uses computer vision cascade object detectors, which are trained to detect predetermined, distinct landmarks prior to a flight. The first method also concurrently explores aircraft localization using roads between landmark updates. During a flight, the aircraft navigates with attitude, heading, airspeed, and altitude measurements and obtains measurement updates when landmarks are detected. The sensor measurements and landmark coordinates extracted from the aircraft's camera images are combined into an unscented Kalman filter to obtain an estimate of the aircraft's position and wind velocities. The second method uses computer vision object detectors to detect abundant generic landmarks referred as buildings, fields, trees, and road intersections from aerial perspectives. Various landmark attributes and spatial relationships to other landmarks are used to help associate observed landmarks with reference landmarks. The computer vision algorithms automatically extract reference landmarks from maps, which are processed offline before a flight. During a flight, the aircraft navigates with attitude, heading, airspeed, and altitude measurements and obtains measurement corrections by processing aerial photos with similar generic landmark detection techniques. The method also combines sensor measurements and landmark coordinates into an unscented Kalman filter to obtain an estimate of the aircraft's position and wind velocities.
Bayesian estimation of optical properties of the human head via 3D structural MRI
NASA Astrophysics Data System (ADS)
Barnett, Alexander H.; Culver, Joseph P.; Sorensen, A. Gregory; Dale, Anders M.; Boas, David A.
2003-10-01
Knowledge of the baseline optical properties of the tissues of the human head is essential for absolute cerebral oximetry, and for quantitative studies of brain activation. In this work we numerically model the utility of signals from a small 6-optode time-resolved diffuse optical tomographic apparatus for inferring baseline scattering and absorption coefficients of the scalp, skull and brain, when complete geometric information is available from magnetic resonance imaging (MRI). We use an optical model where MRI-segmented tissues are assumed homogeneous. We introduce a noise model capturing both photon shot noise and forward model numerical accuracy, and use Bayesian inference to predict errorbars and correlations on the measurments. We also sample from the full posterior distribution using Markov chain Monte Carlo. We conclude that ~ 106 detected photons are sufficient to measure the brain"s scattering and absorption to a few percent. We present preliminary results using a fast multi-layer slab model, comparing the case when layer thicknesses are known versus unknown.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corradini, N; Leick, M; Bonetti, M
Purpose: To determine the MVCT imaging uncertainty on the TomoHDA system for intracranial radiosurgery treatments. To determine the end-to-end (E2E) overall accuracy of the TomoHDA system for intracranial radiosurgery. Methods: A pig head was obtained from the butcher, cut coronally through the brain, and preserved in formaldehyde. The base of the head was fixed to a positioning plate allowing precise movement, i.e. translation and rotation, in all 6 axes. A repeatability test was performed on the pig head to determine uncertainty in the image bone registration algorithm. Furthermore, the test studied images with MVCT slice thicknesses of 1 and 3more » mm in unison with differing scan lengths. A sensitivity test was performed to determine the registration algorithm’s ability to find the absolute position of known translations/rotations of the pig head. The algorithm’s ability to determine absolute position was compared against that of manual operators, i.e. a radiation therapist and radiation oncologist. Finally, E2E tests for intracranial radiosurgery were performed by measuring the delivered dose distributions within the pig head using Gafchromic films. Results: The repeatability test uncertainty was lowest for the MVCTs of 1-mm slice thickness, which measured less than 0.10 mm and 0.12 deg for all axes. For the sensitivity tests, the bone registration algorithm performed better than human eyes and a maximum difference of 0.3 mm and 0.4 deg was observed for the axes. E2E test results in absolute position difference measured 0.03 ± 0.21 mm in x-axis and 0.28 ± 0.18 mm in y-axis. A maximum difference of 0.32 and 0.66 mm was observed in x and y, respectively. The average peak dose difference between measured and calculated dose was 2.7 cGy or 0.4%. Conclusion: Our tests using a pig head phantom estimate the TomoHDA system to have a submillimeter overall accuracy for intracranial radiosurgery.« less
Exfoliated cells of the oral mucosa for HPV typing by SPF10 in head and neck cancer.
Morbini, Patrizia; Dal Bello, Barbara; Alberizzi, Paola; Mannarini, Laura; Mevio, Niccolò; Bertino, Giulia; Benazzo, Marco
2012-12-01
HPV infection in the superficial cells of the oral mucosa could reflect the presence of HPV in head and neck cancer cells. Due mostly to the use of heterogeneous analytical methods, discordant data exist in the literature regarding the agreement between the presence of HPV in non-neoplastic oral mucosa and in tumour tissue from the same patient. The presence of HPV DNA and viral types were compared in paired cytological and biopsy samples from 56 patients with head and neck neoplastic and preneoplastic lesions using the highly sensitive SPF10 LiPA Extra assay, which has been validated recently for formalin-fixed paraffin-embedded tissue using paired cervical cytology and biopsy samples. Kappa statistics were used to measure the inter-rater agreement. The overall agreement with respect to HPV infection was 96.43% (kappa=0.8367). For 76.79% of subjects (kappa=0.6937), the same number of HPV types was detected in cytological and biopsy specimens. The overall positive typing agreement was 90.90%, comprising 130 out of 143 individual HPV type analyses. The agreement shown was good for HPV 18, 44, 45, 54 and 66 (kappa=0.6585-0. 7321), excellent for HPV 6, 16, 40, and 54 (kappa=0.8108-0.8679), and absolute for HPV 11, 31, 33, 35, 39, 51, 52, 53, 59, 74, and 69-71 (kappa=1.0000). The high sensitivity of the SPF10 LiPA and its excellent performance both for recognising HPV infection and for identifying the viral types present in tumour tissue and in oral exfoliated cells make it a useful method for the assessment of HPV infection in patients with head and neck cancer. The excellent agreement for HPV infection and genotyping in paired samples suggests that oral exfoliated cells can be used for HPV detection in the head and neck region. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
A, Popescu I; Lobo, J; Sawkey, D
2014-06-15
Purpose: To simulate and measure radiation backscattered into the monitor chamber of a TrueBeam linac; establish a rigorous framework for absolute dose calculations for TrueBeam Monte Carlo (MC) simulations through a novel approach, taking into account the backscattered radiation and the actual machine output during beam delivery; improve agreement between measured and simulated relative output factors. Methods: The ‘monitor backscatter factor’ is an essential ingredient of a well-established MC absolute dose formalism (the MC equivalent of the TG-51 protocol). This quantity was determined for the 6 MV, 6X FFF, and 10X FFF beams by two independent Methods: (1) MC simulationsmore » in the monitor chamber of the TrueBeam linac; (2) linac-generated beam record data for target current, logged for each beam delivery. Upper head MC simulations used a freelyavailable manufacturer-provided interface to a cloud-based platform, allowing use of the same head model as that used to generate the publicly-available TrueBeam phase spaces, without revealing the upper head design. The MC absolute dose formalism was expanded to allow direct use of target current data. Results: The relation between backscatter, number of electrons incident on the target for one monitor unit, and MC absolute dose was analyzed for open fields, as well as a jaw-tracking VMAT plan. The agreement between the two methods was better than 0.15%. It was demonstrated that the agreement between measured and simulated relative output factors improves across all field sizes when backscatter is taken into account. Conclusion: For the first time, simulated monitor chamber dose and measured target current for an actual TrueBeam linac were incorporated in the MC absolute dose formalism. In conjunction with the use of MC inputs generated from post-delivery trajectory-log files, the present method allows accurate MC dose calculations, without resorting to any of the simplifying assumptions previously made in the TrueBeam MC literature. This work has been partially funded by Varian Medical Systems.« less
Bright, Chloe J; Hawkins, Mike M; Guha, Joyeeta; Henson, Katherine E; Winter, David L; Kelly, Julie S; Feltbower, Richard G; Hall, Marlous; Cutter, David J; Edgar, Angela B; Frobisher, Clare; Reulen, Raoul C
2017-03-28
Survivors of teenage and young adult cancer are at risk of cerebrovascular events, but the magnitude of and extent to which this risk varies by cancer type, decade of diagnosis, age at diagnosis, and attained age remains uncertain. This is the largest-ever cohort study to evaluate the risks of hospitalization for a cerebrovascular event among long-term survivors of teenage and young adult cancer. The population-based TYACSS (Teenage and Young Adult Cancer Survivor Study) (N=178,962) was linked to Hospital Episode Statistics data for England to investigate the risks of hospitalization for a cerebrovascular event among 5-year survivors of cancer diagnosed when 15 to 39 years of age. Observed numbers of first hospitalizations for cerebrovascular events were compared with that expected from the general population using standardized hospitalization ratios (SHRs) and absolute excess risks per 10 000 person-years. Cumulative incidence was calculated with death considered a competing risk. Overall, 2782 cancer survivors were hospitalized for a cerebrovascular event-40% higher than expected (SHR=1.4, 95% confidence interval, 1.3-1.4). Survivors of central nervous system (CNS) tumors (SHR=4.6, 95% confidence interval, 4.3-5.0), head and neck tumors (SHR=2.6, 95% confidence interval, 2.2-3.1), and leukemia (SHR=2.5, 95% confidence interval, 1.9-3.1) were at greatest risk. Males had significantly higher absolute excess risks than females (absolute excess risks =7 versus 3), especially among head and neck tumor survivors (absolute excess risks =30 versus 11). By 60 years of age, 9%, 6%, and 5% of CNS tumor, head and neck tumor, and leukemia survivors, respectively, had been hospitalized for a cerebrovascular event. Beyond 60 years of age, every year, 0.4% of CNS tumor survivors were hospitalized for a cerebral infarction (versus 0.1% expected), whereas at any age, every year, 0.2% of head and neck tumor survivors were hospitalized for a cerebral infarction (versus 0.06% expected). Survivors of a CNS tumor, head and neck tumor, and leukemia are particularly at risk of hospitalization for a cerebrovascular event. The excess risk of cerebral infarction among CNS tumor survivors increases with attained age. For head and neck tumor survivors, this excess risk remains high across all ages. These groups of survivors, particularly males, should be considered for surveillance of cerebrovascular risk factors and potential pharmacological interventions for cerebral infarction prevention. © 2017 American Heart Association, Inc.
3D interferometric shape measurement technique using coherent fiber bundles
NASA Astrophysics Data System (ADS)
Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen
2017-06-01
In-situ 3-D shape measurements with submicron shape uncertainty of fast rotating objects in a cutting lathe are expected, which can be achieved by simultaneous distance and velocity measurements. Conventional tactile methods, coordinate measurement machines, only support ex-situ measurements. Optical measurement techniques such as triangulation and conoscopic holography offer only the distance, so that the absolute diameter cannot be retrieved directly. In comparison, laser Doppler distance sensors (P-LDD sensor) enable simultaneous and in-situ distance and velocity measurements for monitoring the cutting process in a lathe. In order to achieve shape measurement uncertainties below 1 μm, a P-LDD sensor with a dual camera based scattered light detection has been investigated. Coherent fiber bundles (CFB) are employed to forward the scattered light towards cameras. This enables a compact and passive sensor head in the future. Compared with a photo detector based sensor, the dual camera based sensor allows to decrease the measurement uncertainty by the order of one magnitude. As a result, the total shape uncertainty of absolute 3-D shape measurements can be reduced to about 100 nm.
On the sensitivity of TG-119 and IROC credentialing to TPS commissioning errors.
McVicker, Drew; Yin, Fang-Fang; Adamson, Justus D
2016-01-08
We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical anisotropic algorithm within a commercial treatment planning system. Errors were implemented into the various components of the dose calculation algorithm including primary photons, secondary photons, electron contamination, and MLC parameters. For each error we evaluated the probability that it could be committed unknowingly during the dose algorithm commissioning stage, and the probability of it being identified during the verification stage. The clinical impact of each commissioning error was evaluated using representative IMRT plans including low and intermediate risk prostate, head and neck, mesothelioma, and scalp; the sensitivity of the TG-119 and IROC phantoms was evaluated by comparing dosimetric changes to the dose planes where film measurements occur and change in point doses where dosimeter measurements occur. No commissioning errors were found to have both a low probability of detection and high clinical severity. When errors do occur, the IROC credentialing and TG 119 commissioning criteria are generally effective at detecting them; however, for the IROC phantom, OAR point-dose measurements are the most sensitive despite being currently excluded from IROC analysis. Point-dose measurements with an absolute dose constraint were the most effective at detecting errors, while film analysis using a gamma comparison and the IROC film distance to agreement criteria were less effective at detecting the specific commissioning errors implemented here.
Sosson, Charlotte; Georges, Carrie; Guillaume, Mathieu; Schuller, Anne-Marie; Schiltz, Christine
2018-01-01
Numbers are thought to be spatially organized along a left-to-right horizontal axis with small/large numbers on its left/right respectively. Behavioral evidence for this mental number line (MNL) comes from studies showing that the reallocation of spatial attention by active left/right head rotation facilitated the generation of small/large numbers respectively. While spatial biases in random number generation (RNG) during active movement are well established in adults, comparable evidence in children is lacking and it remains unclear whether and how children’s access to the MNL is affected by active head rotation. To get a better understanding of the development of embodied number processing, we investigated the effect of active head rotation on the mean of generated numbers as well as the mean difference between each number and its immediately preceding response (the first order difference; FOD) not only in adults (n = 24), but also in 7- to 11-year-old elementary school children (n = 70). Since the sign and absolute value of FODs carry distinct information regarding spatial attention shifts along the MNL, namely their direction (left/right) and size (narrow/wide) respectively, we additionally assessed the influence of rotation on the total of negative and positive FODs regardless of their numerical values as well as on their absolute values. In line with previous studies, adults produced on average smaller numbers and generated smaller mean FODs during left than right rotation. More concretely, they produced more negative/positive FODs during left/right rotation respectively and the size of negative FODs was larger (in terms of absolute value) during left than right rotation. Importantly, as opposed to adults, no significant differences in RNG between left and right head rotations were observed in children. Potential explanations for such age-related changes in the effect of active head rotation on RNG are discussed. Altogether, the present study confirms that numerical processing is spatially grounded in adults and suggests that its embodied aspect undergoes significant developmental changes. PMID:29541048
Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen
2012-07-01
To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.
Shin, Seung-Han; Lee, Yong-Suk; Kang, Jin-Woo; Noh, Dong-Young; Jung, Joon-Yong; Chung, Yang-Guk
2018-03-01
The location of the ulnar styloid process can be confusing because the radius and the hand rotate around the ulna. The purpose of this study was to identify the absolute location of the ulnar styloid process, which is independent of forearm pronation or supination, to use it as a reference for neutral forearm rotation on lateral radiographs of the wrist. Computed tomography (CT) images of 23 forearms taken with elbow flexion of 70° to 90° were analyzed. The axial CT images were reconstructed to be perpendicular to the distal ulnar shaft. The absolute location of the ulnar styloid process in this study was defined as the position of the ulnar styloid process on the axial plane of the ulnar head relative to the long axis of the humeral shaft with the elbow set in the position for standard lateral radiographs of the wrist. To identify in which direction the ulnar styloid is located on the axial plane of the ulnar head, the angle between "the line of humeral long axis projected on the axial plane of the ulna" and "the line passing the center of the ulnar head and the center of the ulnar styloid" was measured (ulnar styloid direction angle). To identify how volarly or dorsally the ulnar styloid should appear on the true lateral view of the wrist, the ratio of "the volar-dorsal diameter of the ulnar head" and "the distance between the volar-most aspect of the ulnar head and the center of the ulnar styloid" was calculated (ulnar styloid location ratio). The mean ulnar styloid direction angle was 12° dorsally. The mean ulnar styloid location ratio was 1:0.55. The ulnar styloid is located at nearly the ulnar-most (the opposite side of the humerus with the elbow flexed) and slightly dorsal aspects of the ulnar head on the axial plane. It should appear almost midway (55% dorsally) from the ulnar head on the standard lateral view of the wrist in neutral forearm rotation. These location references could help clinicians determine whether the forearm is in neutral or rotated position on an axial CT/magnetic resonance imaging scan or a lateral radiograph of the wrist.
Kaliontzopoulou, Antigoni; Carretero, M A; Llorente, G A
2010-06-01
Morphological variation in relation to habitat is known to occur in several lizard groups. Comparative studies have linked morphology and habitat use, showing that locomotion is the principal mediator of this evolutionary relationship. Here, we investigate intraspecific ecomorphological variation in Podarcis bocagei by examining three habitat types, representing a variety between saxicolous and ground-dwelling habits. Our results indicate variation in absolute and relative limb length, but patterns are only partially concordant to biomechanical predictions. Whereas the femur and hind foot are longer in ground-dwelling lizards, confirming previous observations, the tibia and hind limb are relatively shorter, contradicting expectations. Additionally, head shape varies substantially between habitats, in line with a hypothesis of mechanical restrictions related to microhabitat and refuge use. Finally, we detect male-specific variation between habitats in total body size and head size, providing evidence for interactions between natural and sexual selection. Although performance and behaviour studies are necessary to definitely confirm the functional and evolutionary significance of the observed patterns, our study indicates that ecomorphological adaptations can arise in a very short evolutionary time in this group of lizards.
Zhu, Pengyu; Fu, Wei; Wang, Chenguang; Du, Zhixin; Huang, Kunlun; Zhu, Shuifang; Xu, Wentao
2016-04-15
The possibility of the absolute quantitation of GMO events by digital PCR was recently reported. However, most absolute quantitation methods based on the digital PCR required pretreatment steps. Meanwhile, singleplex detection could not meet the demand of the absolute quantitation of GMO events that is based on the ratio of foreign fragments and reference genes. Thus, to promote the absolute quantitative detection of different GMO events by digital PCR, we developed a quantitative detection method based on duplex digital PCR without pretreatment. Moreover, we tested 7 GMO events in our study to evaluate the fitness of our method. The optimized combination of foreign and reference primers, limit of quantitation (LOQ), limit of detection (LOD) and specificity were validated. The results showed that the LOQ of our method for different GMO events was 0.5%, while the LOD is 0.1%. Additionally, we found that duplex digital PCR could achieve the detection results with lower RSD compared with singleplex digital PCR. In summary, the duplex digital PCR detection system is a simple and stable way to achieve the absolute quantitation of different GMO events. Moreover, the LOQ and LOD indicated that this method is suitable for the daily detection and quantitation of GMO events. Copyright © 2016 Elsevier B.V. All rights reserved.
Marimuthu, Arivusudar; Chavan, Sandip; Sathe, Gajanan; Sahasrabuddhe, Nandini A; Srikanth, Srinivas M; Renuse, Santosh; Ahmad, Sartaj; Radhakrishnan, Aneesha; Barbhuiya, Mustafa A; Kumar, Rekha V; Harsha, H C; Sidransky, David; Califano, Joseph; Pandey, Akhilesh; Chatterjee, Aditi
2013-11-01
Protein biomarker discovery for early detection of head and neck squamous cell carcinoma (HNSCC) is a crucial unmet need to improve patient outcomes. Mass spectrometry-based proteomics has emerged as a promising tool for identification of biomarkers in different cancer types. Proteins secreted from cancer cells can serve as potential biomarkers for early diagnosis. In the current study, we have used isobaric tag for relative and absolute quantitation (iTRAQ) labeling methodology coupled with high resolution mass spectrometry to identify and quantitate secreted proteins from a panel of head and neck carcinoma cell lines. In all, we identified 2,472 proteins, of which 225 proteins were secreted at higher or lower abundance in HNSCC-derived cell lines. Of these, 148 were present in higher abundance and 77 were present in lower abundance in the cancer-cell derived secretome. We detected a higher abundance of some previously known markers for HNSCC including insulin like growth factor binding protein 3, IGFBP3 (11-fold) and opioid growth factor receptor, OGFR (10-fold) demonstrating the validity of our approach. We also identified several novel secreted proteins in HNSCC including olfactomedin-4, OLFM4 (12-fold) and hepatocyte growth factor activator, HGFA (5-fold). IHC-based validation was conducted in HNSCC using tissue microarrays which revealed overexpression of IGFBP3 and OLFM4 in 70% and 75% of the tested cases, respectively. Our study illustrates quantitative proteomics of secretome as a robust approach for identification of potential HNSCC biomarkers. This article is part of a Special Issue entitled: An Updated Secretome. Copyright © 2013 Elsevier B.V. All rights reserved.
Commercial golf glove effects on golf performance and forearm muscle activity.
Sorbie, Graeme G; Darroch, Paul; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike C
2017-01-01
The study aimed to determine whether or not commercial golf gloves influence performance variables and forearm muscle activity during golf play. Fifteen golfers participated in the laboratory based study, each performing 8 golf swings with a Driver and 7-iron whilst wearing a glove and 8 without wearing the glove. Club head speed, ball speed and absolute carry distance performance variables were calculated. Surface electromyography was recorded from the flexor digitorum superficialis and extensor carpi radialis brevis on both forearm muscles. Club head speed, ball speed and absolute carry distance was significantly higher when using the Driver with the glove in comparison to the Driver without the glove (p < 0.05). No significant differences were evident when using the 7-iron and no significant differences were displayed in muscle activity in either of the conditions. Findings from this study suggest that driving performance is improved when wearing a glove.
In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.
Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J
2004-01-01
In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.
Pettorossi, V E; Ermanno, M; Pierangelo, E; Silvarosa, G
2000-03-01
The influence of gravity in the orientation and slow phase eye velocity of the ocular nystagmus following unilateral damage of the cupula in the ampulla of the horizontal semicircular canal (UHCD) was investigated. The nystagmus was analysed at different sagittal head positions using the x-y infrared eye monitor technique. The nystagmus was almost horizontal at 0 degrees head pitch angle and remained partially fixed in space when the head was pitched upward or downward. The reorientation gain of the slow and quick phases was high (about 0.75) within +/- 45 degrees of head pitch angle, but beyond this range, it decreased greatly. The gain value depended on the lesion extension to otolithic receptors. The absolute value of the slow phase eye velocity of UHCD nystagmus was also modified systematically by the head pitch, showing a reduction in the upward and an increase in the downward.
Head repositioning accuracy to neutral: a comparative study of error calculation.
Hill, Robert; Jensen, Pål; Baardsen, Tor; Kulvik, Kristian; Jull, Gwendolen; Treleaven, Julia
2009-02-01
Deficits in cervical proprioception have been identified in subjects with neck pain through the measure of head repositioning accuracy (HRA). Nevertheless there appears to be no general consensus regarding the construct of measurement of error used for calculating HRA. This study investigated four different mathematical methods of measurement of error to determine if there were any differences in their ability to discriminate between a control group and subjects with a whiplash associated disorder. The four methods for measuring cervical joint position error were calculated using a previous data set consisting of 50 subjects with whiplash complaining of dizziness (WAD D), 50 subjects with whiplash not complaining of dizziness (WAD ND) and 50 control subjects. The results indicated that no one measure of HRA uniquely detected or defined the differences between the whiplash and control groups. Constant error (CE) was significantly different between the whiplash and control groups from extension (p<0.05). Absolute errors (AEs) and root mean square errors (RMSEs) demonstrated differences between the two WAD groups in rotation trials (p<0.05). No differences were seen with variable error (VE). The results suggest that a combination of AE (or RMSE) and CE are probably the most suitable measures for analysis of HRA.
2015-09-01
OPTICAL FLOW SENSORS FOR DEAD RECKONING, HEADING REFERENCE, OBSTACLE DETECTION, AND OBSTACLE AVOIDANCE by Tarek M. Nejah September 2015...SENSORS FOR DEAD RECKONING, HEADING REFERENCE, OBSTACLE DETECTION, AND OBSTACLE AVOIDANCE 5. FUNDING NUMBERS 6. AUTHOR(S) Nejah, Tarek M. 7...DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) A novel approach for dead reckoning, heading reference, obstacle detection, and obstacle
At what age is hydrocephalus detected, and what is the role of head circumference measurements?
Breuning-Broers, Jacqueline M; Deurloo, Jacqueline A; Gooskens, Rob H; Verkerk, Paul H
2014-02-01
To investigate at what age hydrocephalus is detected and to assess the role of head circumference measurements in detecting hydrocephalus, we performed a retrospective chart review in children with hydrocephalus treated in a tertiary paediatric hospital in the Netherlands. The study group contained 146 patients; 38 patients (31%) were referred because of abnormalities in head circumference. Eighty-nine per cent of the patients were detected in the first year of life. After this period, no patients were referred because of an abnormal head circumference. Therefore, head circumference measurements seem to have little value for detecting hydrocephalus after the first year of life.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tinhofer, Ingeborg, E-mail: ingeborg.tinhofer@charite.de; Hristozova, Tsvetana; Stromberger, Carmen
2012-08-01
Purpose: The numbers of circulating tumor cells (CTCs) and their expression/activation of epidermal growth factor receptor (EGFR) during the course of combined chemo- or bioradiotherapy regimens as potential biomarkers of treatment efficacy in squamous cell carcinoma of the head and neck (SCCHN) were determined. Methods and Materials: Peripheral blood samples from SCCHN patients with locally advanced stage IVA/B disease who were treated with concurrent radiochemotherapy or induction chemotherapy followed by bioradiation with cetuximab were included in this study. Using flow cytometry, the absolute number of CTCs per defined blood volume as well as their expression of EGFR and its phosphorylatedmore » form (pEGFR) during the course of treatment were assessed. Results: Before treatment, we detected {>=}1 CTC per 3.75 mL blood in 9 of 31 patients (29%). Basal expression of EGFR was detected in 100% and pEGFR in 55% of the CTC+ cases. The frequency of CTC detection was not influenced by induction chemotherapy. However, the number of CTC+ samples significantly increased after radiotherapy. This radiation-induced increase in CTC numbers was less pronounced when radiotherapy was combined with cetuximab compared to its combination with cisplatin/5-fluorouracil. The former treatment regimen was also more effective in reducing pEGFR expression in CTCs. Conclusions: Definitive radiotherapy regimens of locally advanced SCCHN can increase the number of CTCs and might thus contribute to a systemic spread of tumor cells. Further studies are needed to evaluate the predictive value of the radiation-induced increase in CTC numbers and the persistent activation of the EGFR signalling pathway in individual CTC+ cases.« less
Brew, Christopher J; Simpson, Philip M; Whitehouse, Sarah L; Donnelly, William; Crawford, Ross W; Hubble, Matthew J W
2012-04-01
We describe a scaling method for templating digital radiographs using conventional acetate templates independent of template magnification without the need for a calibration marker. The mean magnification factor for the radiology department was determined (119.8%; range, 117%-123.4%). This fixed magnification factor was used to scale the radiographs by the method described. Thirty-two femoral heads on postoperative total hip arthroplasty radiographs were then measured and compared with the actual size. The mean absolute accuracy was within 0.5% of actual head size (range, 0%-3%) with a mean absolute difference of 0.16 mm (range, 0-1 mm; SD, 0.26 mm). Intraclass correlation coefficient showed excellent reliability for both interobserver and intraobserver measurements with intraclass correlation coefficient scores of 0.993 (95% CI, 0.988-0.996) for interobserver measurements and intraobserver measurements ranging between 0.990 and 0.993 (95% CI, 0.980-0.997). Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.
Schinagl, Dominic A X; Vogel, Wouter V; Hoffmann, Aswin L; van Dalen, Jorn A; Oyen, Wim J; Kaanders, Johannes H A M
2007-11-15
Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with (18)F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may improve definition of the gross tumor volume (GTV). In this study, five methods for tumor delineation on FDG-PET are compared with CT-based delineation. Seventy-eight patients with Stages II-IV squamous cell carcinoma of the head and neck area underwent coregistered CT and FDG-PET. The primary tumor was delineated on CT, and five PET-based GTVs were obtained: visual interpretation, applying an isocontour of a standardized uptake value of 2.5, using a fixed threshold of 40% and 50% of the maximum signal intensity, and applying an adaptive threshold based on the signal-to-background ratio. Absolute GTV volumes were compared, and overlap analyses were performed. The GTV method of applying an isocontour of a standardized uptake value of 2.5 failed to provide successful delineation in 45% of cases. For the other PET delineation methods, volume and shape of the GTV were influenced heavily by the choice of segmentation tool. On average, all threshold-based PET-GTVs were smaller than on CT. Nevertheless, PET frequently detected significant tumor extension outside the GTV delineated on CT (15-34% of PET volume). The choice of segmentation tool for target-volume definition of head and neck cancer based on FDG-PET images is not trivial because it influences both volume and shape of the resulting GTV. With adequate delineation, PET may add significantly to CT- and physical examination-based GTV definition.
Absolute calibration of a multichannel plate detector for low energy O, O-, and O+
NASA Astrophysics Data System (ADS)
Stephen, T. M.; Peko, B. L.
2000-03-01
Absolute detection efficiencies of a commercial multichannel plate detector have been measured for O, O+, and O-, impacting at normal incidence for energies ranging from 30-1000 eV. In addition, the detection efficiencies for O relative to its ions are presented, as they may have a more universal application. The absolute detection efficiencies are strongly energy dependent and significant differences are observed for the various charge states at lower energies. The detection efficiencies for the different charge states appear to converge at higher energies. The strongest energy dependence is for O+; the detection efficiency varies by three orders of magnitude across the energy range studied. The weakest dependence is for O-, which varies less than one order of magnitude.
Rapid decrease of radar cross section of meteor head echo observed by the MU radar
NASA Astrophysics Data System (ADS)
Nakamura, T.; Nishio, M.; Sato, T.; Tsutsumi, S.; Tsuda, T.; Fushimi, K.
The meteor head echo observation using the MU (Middle and Upper atmosphere) radar (46.5M Hz, 1MW), Shigaraki, Japan, was carried out simultaneously with a high sensitive ICCD (Image-intensified CCD) camera observation in November 2001. The time records were synchronized using GPS satellite signals, in order to compare instantaneous radar and optical meteor magnitudes. 26 faint meteors were successfully observed simultaneously by both equipments. Detailed comparison of the time variation of radar echo intensity and absolute optical magnitude showed that the radar scattering cross section is likely to decrease rapidly by 5 - 20 dB without no corresponding magnitude variation in the optical data. From a simple modeling, we concluded that such decrease of RCS (radar cross section ) is probably due to the transition from overdense head echo to underd ense head echo.
Lee, Jongshill; Chee, Youngjoon; Kim, Inyoung; Karpettas, Nikos; Kollias, Anastasios; Atkins, Neil; Stergiou, George S; O'Brien, Eoin
2015-10-01
This study describes the development of a new digital sphygmocorder (DS-II), which allows the digital recording and playback of the Korotkoff sounds, together with cuff pressure waveform, and its performance in a pilot validation study. A condenser microphone and stethoscope head detect Korotkoff sounds and an electronic chip, dedicated to audio-signal processing, is used to record high-quality sounds. Systolic and diastolic blood pressure (SBP/DBP) are determined from the recorded signals with an automatic beat detection algorithm that displays the cuff pressure at each beat on the monitor. Recordings of Korotkoff sounds, with the cuff pressure waveforms, and the simultaneous on-site assessments of SBP/DBP were performed during 100 measurements in 10 individuals. The observers reassessed the recorded signals to verify their accuracy and differences were calculated. The features of the high-fidelity DS-II, the technical specifications and the assessment procedures utilizing the playback software are described. Interobserver absolute differences (mean±SD) in measurements were 0.7±1.1/1.3±1.3 mmHg (SBP/DBP) with a mercury sphygmomanometer and 0.3±0.9/0.8±1.2 mmHg with the DS-II. The absolute DS-II mercury sphygmomanometer differences were 1.3±1.9/1.5±1.3 mmHg (SBP/DBP). The high-fidelity DS-II device presents satisfactory agreement with simultaneous measurements of blood pressure with a mercury sphygmomanometer. The device will be a valuable methodology for validating new blood pressure measurement technologies and devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dance, M; Chera, B; Falchook, A
2015-06-15
Purpose: Validate the consistency of a gradient-based segmentation tool to facilitate accurate delineation of PET/CT-based GTVs in head and neck cancers by comparing against hybrid PET/MR-derived GTV contours. Materials and Methods: A total of 18 head and neck target volumes (10 primary and 8 nodal) were retrospectively contoured using a gradient-based segmentation tool by two observers. Each observer independently contoured each target five times. Inter-observer variability was evaluated via absolute percent differences. Intra-observer variability was examined by percentage uncertainty. All target volumes were also contoured using the SUV percent threshold method. The thresholds were explored case by case so itsmore » derived volume matched with the gradient-based volume. Dice similarity coefficients (DSC) were calculated to determine overlap of PET/CT GTVs and PET/MR GTVs. Results: The Levene’s test showed there was no statistically significant difference of the variances between the observer’s gradient-derived contours. However, the absolute difference between the observer’s volumes was 10.83%, with a range from 0.39% up to 42.89%. PET-avid regions with qualitatively non-uniform shapes and intensity levels had a higher absolute percent difference near 25%, while regions with uniform shapes and intensity levels had an absolute percent difference of 2% between observers. The average percentage uncertainty between observers was 4.83% and 7%. As the volume of the gradient-derived contours increased, the SUV threshold percent needed to match the volume decreased. Dice coefficients showed good agreement of the PET/CT and PET/MR GTVs with an average DSC value across all volumes at 0.69. Conclusion: Gradient-based segmentation of PET volume showed good consistency in general but can vary considerably for non-uniform target shapes and intensity levels. PET/CT-derived GTV contours stemming from the gradient-based tool show good agreement with the anatomically and metabolically more accurate PET/MR-derived GTV contours, but tumor delineation accuracy can be further improved with the use PET/MR.« less
Setting Standards for Minimum Competency Tests.
ERIC Educational Resources Information Center
Mehrens, William A.
Some general questions about minimum competency tests are discussed, and various methods of setting standards are reviewed with major attention devoted to those methods used for dichotomizing a continuum. Methods reviewed under the heading of Absolute Judgments of Test Content include Nedelsky's, Angoff's, Ebel's, and Jaeger's. These methods are…
Why Our Nation Tolerates Risks to Children.
ERIC Educational Resources Information Center
Penning, Nick
1991-01-01
Contrasts children's well-being and family support services in the United States with superior programs in Germany and other industrialized countries. The American Association of School Administrators considers the Children's Investment Trust, authored by Head Start founding administrator Jule Sugarman, an absolute must for improving children's…
Human recognition based on head-shoulder contour extraction and BP neural network
NASA Astrophysics Data System (ADS)
Kong, Xiao-fang; Wang, Xiu-qin; Gu, Guohua; Chen, Qian; Qian, Wei-xian
2014-11-01
In practical application scenarios like video surveillance and human-computer interaction, human body movements are uncertain because the human body is a non-rigid object. Based on the fact that the head-shoulder part of human body can be less affected by the movement, and will seldom be obscured by other objects, in human detection and recognition, a head-shoulder model with its stable characteristics can be applied as a detection feature to describe the human body. In order to extract the head-shoulder contour accurately, a head-shoulder model establish method with combination of edge detection and the mean-shift algorithm in image clustering has been proposed in this paper. First, an adaptive method of mixture Gaussian background update has been used to extract targets from the video sequence. Second, edge detection has been used to extract the contour of moving objects, and the mean-shift algorithm has been combined to cluster parts of target's contour. Third, the head-shoulder model can be established, according to the width and height ratio of human head-shoulder combined with the projection histogram of the binary image, and the eigenvectors of the head-shoulder contour can be acquired. Finally, the relationship between head-shoulder contour eigenvectors and the moving objects will be formed by the training of back-propagation (BP) neural network classifier, and the human head-shoulder model can be clustered for human detection and recognition. Experiments have shown that the method combined with edge detection and mean-shift algorithm proposed in this paper can extract the complete head-shoulder contour, with low calculating complexity and high efficiency.
Note: An absolute X-Y-Θ position sensor using a two-dimensional phase-encoded binary scale
NASA Astrophysics Data System (ADS)
Kim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan
2018-04-01
This Note presents a new absolute X-Y-Θ position sensor for measuring planar motion of a precision multi-axis stage system. By analyzing the rotated image of a two-dimensional phase-encoded binary scale (2D), the absolute 2D position values at two separated points were obtained and the absolute X-Y-Θ position could be calculated combining these values. The sensor head was constructed using a board-level camera, a light-emitting diode light source, an imaging lens, and a cube beam-splitter. To obtain the uniform intensity profiles from the vignette scale image, we selected the averaging directions deliberately, and higher resolution in the angle measurement could be achieved by increasing the allowable offset size. The performance of a prototype sensor was evaluated in respect of resolution, nonlinearity, and repeatability. The sensor could resolve 25 nm linear and 0.001° angular displacements clearly, and the standard deviations were less than 18 nm when 2D grid positions were measured repeatedly.
40 CFR 1065.510 - Engine mapping.
Code of Federal Regulations, 2012 CFR
2012-07-01
... expected maximum power. Continue the warm-up until the engine coolant, block, or head absolute temperature... torque of zero on the engine's primary output shaft, and allow the engine to govern the speed. Measure... values. (ii) For engines without a low-speed governor, operate the engine at warm idle speed and zero...
40 CFR 1065.510 - Engine mapping.
Code of Federal Regulations, 2014 CFR
2014-07-01
... expected maximum power. Continue the warm-up until the engine coolant, block, or head absolute temperature... torque of zero on the engine's primary output shaft, and allow the engine to govern the speed. Measure... values. (ii) For engines without a low-speed governor, operate the engine at warm idle speed and zero...
40 CFR 1065.510 - Engine mapping.
Code of Federal Regulations, 2013 CFR
2013-07-01
... expected maximum power. Continue the warm-up until the engine coolant, block, or head absolute temperature... torque of zero on the engine's primary output shaft, and allow the engine to govern the speed. Measure... values. (ii) For engines without a low-speed governor, operate the engine at warm idle speed and zero...
Impact of seasonality and storage of semen on epigenetics in swine placenta and fetal livers
USDA-ARS?s Scientific Manuscript database
Epigenetics includes the study of external factors that can influence the expression of genes by altering accessibility of DNA through methylation and histone modification. To investigate the influence of: season (semen collection and breeding), absolute sperm head-shape change, and semen storage on...
Translation and Rotation Trade Off in Human Visual Heading Estimation
NASA Technical Reports Server (NTRS)
Stone, Leland S.; Perrone, John A.; Null, Cynthia H. (Technical Monitor)
1996-01-01
We have previously shown that, during simulated curvilinear motion, humans can make reasonably accurate and precise heading judgments from optic flow without either oculomotor or static-depth cues about rotation. We now systematically investigate the effect of varying the parameters of self-motion. We visually simulated 400 ms of self-motion along curved paths (constant rotation and translation rates, fixed retinocentric heading) towards two planes of random dots at 10.3 m and 22.3 m at mid-trial. Retinocentric heading judgments of 4 observers (2 naive) were measured for 12 different combinations of translation (T between 4 and 16 m/s) and rotation (R either 8 or 16 deg/s). In the range tested, heading bias and uncertainty decrease quasilinearly with T/R, but the bias also appears to depend on R. If depth is held constant, the ratio T/R can account for much of the variation in the accuracy and precision of human visual heading estimation, although further experiments are needed to resolve whether absolute rotation rate, total flow rate, or some other factor can account for the observed -2 deg shift between the bias curves.
NASA Astrophysics Data System (ADS)
Miyazaki, Yusuke; Tachiya, Hiroshi; Anata, Kenji; Hojo, Akihiro
This study discusses a head injury mechanism in case of a human head subjected to impact, from results of impact experiments by using a physical model of a human head with high-shape fidelity. The physical model was constructed by using rapid prototyping technology from the three-dimensional CAD data, which obtained from CT/MRI images of a subject's head. As results of the experiments, positive pressure responses occurred at the impacted site, whereas negative pressure responses occurred at opposite the impacted site. Moreover, the absolute maximum value of pressure occurring at the frontal region of the intracranial space of the head model resulted in same or higher than that at the occipital site in each case that the impact force was imposed on frontal or occipital region. This result has not been showed in other study using simple shape physical models. And, the result corresponds with clinical evidences that brain contusion mainly occurs at the frontal part in each impact direction. Thus, physical model with accurate skull shape is needed to clarify the mechanism of brain contusion.
Suction performance and internal flow of a 2-bladed helical inducer with inlet asymmetric plate
NASA Astrophysics Data System (ADS)
Watanabe, S.; Uchinono, Y.; Ishizaka, K.; Furukawa, A.; Kim, J.-H.
2013-10-01
It has been found in our past studies that the installation of asymmetric plate at the inlet of inducer is effective for the suppression of cavitation surge phenomenon. In the present study, the suction performance of 2-bladed helical inducer with an inlet asymmetric plate is experimentally investigated. It is observed that the suction performance in large flow rate conditions is not significantly influenced by the asymmetric plate, whereas the head of inducer with the asymmetric plate increases just before the head breakdown in partial flow conditions. To understand the mechanism of this additional head, the flow measurements and the numerical simulations are carried out. It is found that the circumferential component of absolute velocity at the exit of inducer slightly increases with the development of cavitation in both cases with and without the inlet asymmetric plate, indicating the increase of the theoretical head. The theoretical head increase with the inlet asymmetric plate is also confirmed by the unsteady numerical simulations, suggesting that the additional head is achieved through the increase of the theoretical head with the change of the exiting flow from the inducer associated with some amount of cavitation.
Absolute quantification methods in tissue near-infrared spectroscopy
NASA Astrophysics Data System (ADS)
Matcher, Steven J.; Kirkpatrick, Peter J.; Nahid, K.; Cope, Mark; Delpy, David T.
1995-05-01
Recent work aimed at providing an absolute measurement of tissue haemoglobin saturation and a new instrument development, the spatially resolved spectrometer (SRS), are discussed. The theoretical basis of operation of this device and its hardware implementation are described and the results of validation studies on tissue simulating phantoms are presented as are preliminary measurements on human volunteers and observations on patients undergoing neurosurgery. In its present form the instrument appears to produce absolute haemoglobin saturation values for resting human skeletal muscle and the normally perfused human head which are rather low based on physiological expectations. However, we obtained a tight correlation between the saturation values measured by the SRS instrument and those obtained from blood-gas analysis of samples drawn from a jugular bulb catheter in one neurosurgery subject during clamping of the right carotid arteries.
Assessment of InfraScanner 2000™ in Detecting Subdural and Epidural Hematomas
2018-05-18
Head Trauma; Craniocerebral Injuries; Crushing Skull Injury; Head Injuries; Head Injuries, Multiple; Head Injuries, Closed; Head Trauma,Closed; Head Trauma Injury; Head Trauma, Penetrating; Head Injury, Minor; Head Injury Major; Head Injury, Open; Injuries, Craniocerebral; Injuries, Head; Multiple Head Injury; Trauma, Head
Ilyas, Muhammad; Hong, Beomjin; Cho, Kuk; Baeg, Seung-Ho; Park, Sangdeok
2016-01-01
This paper provides algorithms to fuse relative and absolute microelectromechanical systems (MEMS) navigation sensors, suitable for micro planetary rovers, to provide a more accurate estimation of navigation information, specifically, attitude and position. Planetary rovers have extremely slow speed (~1 cm/s) and lack conventional navigation sensors/systems, hence the general methods of terrestrial navigation may not be applicable to these applications. While relative attitude and position can be tracked in a way similar to those for ground robots, absolute navigation information is hard to achieve on a remote celestial body, like Moon or Mars, in contrast to terrestrial applications. In this study, two absolute attitude estimation algorithms were developed and compared for accuracy and robustness. The estimated absolute attitude was fused with the relative attitude sensors in a framework of nonlinear filters. The nonlinear Extended Kalman filter (EKF) and Unscented Kalman filter (UKF) were compared in pursuit of better accuracy and reliability in this nonlinear estimation problem, using only on-board low cost MEMS sensors. Experimental results confirmed the viability of the proposed algorithms and the sensor suite, for low cost and low weight micro planetary rovers. It is demonstrated that integrating the relative and absolute navigation MEMS sensors reduces the navigation errors to the desired level. PMID:27223293
Ilyas, Muhammad; Hong, Beomjin; Cho, Kuk; Baeg, Seung-Ho; Park, Sangdeok
2016-05-23
This paper provides algorithms to fuse relative and absolute microelectromechanical systems (MEMS) navigation sensors, suitable for micro planetary rovers, to provide a more accurate estimation of navigation information, specifically, attitude and position. Planetary rovers have extremely slow speed (~1 cm/s) and lack conventional navigation sensors/systems, hence the general methods of terrestrial navigation may not be applicable to these applications. While relative attitude and position can be tracked in a way similar to those for ground robots, absolute navigation information is hard to achieve on a remote celestial body, like Moon or Mars, in contrast to terrestrial applications. In this study, two absolute attitude estimation algorithms were developed and compared for accuracy and robustness. The estimated absolute attitude was fused with the relative attitude sensors in a framework of nonlinear filters. The nonlinear Extended Kalman filter (EKF) and Unscented Kalman filter (UKF) were compared in pursuit of better accuracy and reliability in this nonlinear estimation problem, using only on-board low cost MEMS sensors. Experimental results confirmed the viability of the proposed algorithms and the sensor suite, for low cost and low weight micro planetary rovers. It is demonstrated that integrating the relative and absolute navigation MEMS sensors reduces the navigation errors to the desired level.
The development and role of megavoltage cone beam computerized tomography in radiation oncology
NASA Astrophysics Data System (ADS)
Morin, Olivier
External beam radiation therapy has now the ability to deliver doses that conform tightly to a tumor volume. The steep dose gradients planned in these treatments make it increasingly important to reproduce the patient position and anatomy at each treatment fraction. For this reason, considerable research now focuses on in-room three-dimensional imaging. This thesis describes the first clinical megavoltage cone beam computed tomography (MVCBCT) system, which utilizes a conventional linear accelerator equipped with an amorphous silicon flat panel detector. The document covers the system development and investigation of its clinical applications over the last 4-5 years. The physical performance of the system was evaluated and optimized for soft-tissue contrast resolution leading to recommendations of imaging protocols to use for specific clinical applications and body sites. MVCBCT images can resolve differences of 5% in electron density for a mean dose of 9 cGy. Hence, the image quality of this system is sufficient to differentiate some soft-tissue structures. The absolute positioning accuracy with MVCBCT is better than 1 mm. The accuracy of isodose lines calculated using MVCBCT images of head and neck patients is within 3% and 3 mm. The system shows excellent stability in image quality, CT# calibration, radiation exposure and absolute positioning over a period of 8 months. A procedure for MVCBCT quality assurance was developed. In our clinic, MVCBCT has been used to detect non rigid spinal cord distortions, to position a patient with a paraspinous tumor close to metallic hardware, to position prostate cancer patients using gold markers or soft-tissue landmarks, to monitor head and neck anatomical changes and their dosimetric consequences, and to complement the convention CT for treatment planning in presence of metallic implants. MVCBCT imaging is changing the clinical practice of our department by increasingly revealing patient-specific errors. New verification protocols are being developed to minimize those errors thus moving the practice of radiation therapy one step closer to personalized medicine.
40 CFR 1065.510 - Engine mapping.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the warm-up until the engine coolant, block, or head absolute temperature is within ± 2% of its mean... demand to minimum, use the dynamometer or other loading device to target a torque of zero on the engine's...-speed governor, operate the engine at warm idle speed and zero torque on the engine's primary output...
40 CFR 1065.935 - Emission test sequence for field testing.
Code of Federal Regulations, 2014 CFR
2014-07-01
... verifications in emission calculations. (5) You may periodically condition and analyze batch samples in-situ... drift corrected results in emissions calculations. (6) Unless you weighed PM in-situ, such as by using... engine in-use until the engine coolant, block, or head absolute temperature is within ±10% of its mean...
40 CFR 1065.935 - Emission test sequence for field testing.
Code of Federal Regulations, 2013 CFR
2013-07-01
... verifications in emission calculations. (5) You may periodically condition and analyze batch samples in-situ... drift corrected results in emissions calculations. (6) Unless you weighed PM in-situ, such as by using... engine in-use until the engine coolant, block, or head absolute temperature is within ±10% of its mean...
40 CFR 1065.935 - Emission test sequence for field testing.
Code of Federal Regulations, 2012 CFR
2012-07-01
... verifications in emission calculations. (5) You may periodically condition and analyze batch samples in-situ... drift corrected results in emissions calculations. (6) Unless you weighed PM in-situ, such as by using... engine in-use until the engine coolant, block, or head absolute temperature is within ±10% of its mean...
40 CFR 1065.935 - Emission test sequence for field testing.
Code of Federal Regulations, 2010 CFR
2010-07-01
... verifications in emission calculations. (5) You may periodically condition and analyze batch samples in-situ... drift corrected results in emissions calculations. (6) Unless you weighed PM in-situ, such as by using... engine in-use until the engine coolant, block, or head absolute temperature is within ±10% of its mean...
40 CFR 1065.935 - Emission test sequence for field testing.
Code of Federal Regulations, 2011 CFR
2011-07-01
... verifications in emission calculations. (5) You may periodically condition and analyze batch samples in-situ... drift corrected results in emissions calculations. (6) Unless you weighed PM in-situ, such as by using... engine in-use until the engine coolant, block, or head absolute temperature is within ±10% of its mean...
Lassen, Pernille; Lacas, Benjamin; Pignon, Jean-Pierre; Trotti, Andy; Zackrisson, Bjorn; Zhang, Qiang; Overgaard, Jens; Blanchard, Pierre
2018-01-01
Evaluate the prognostic and predictive impact of HPV-associated p16-expression and assess the combined prognostic impact of p16 and smoking on altered fractionated radiotherapy (AFRT) for oropharyngeal cancer (OPC) within the frames of the update of the Meta-Analysis of Radiotherapy in Carcinomas of Head and neck (MARCH). Patients with OPC, known tumor p16-status and smoking history were identified from the MARCH update, resulting in a dataset of 815 patients from four randomized trials (RTOG9003, DAHANCA6&7, RTOG0129, ARTSCAN). Analysis was performed using a Cox model stratified by trial and adjusted on gender, age, T-stage, N-stage, type of radiotherapy fractionation, p16, smoking. Primary endpoint was progression-free survival (PFS). In total, 465 patients (57%) had p16-positive tumors and 350 (43%) p16-negative. Compared to p16-negative, p16-positive patients had significantly better PFS (HR = 0.42 [95% CI: 0.34-0.51], 28.9% absolute increase at 10 years) and OS (HR = 0.40 [0.32-0.49], 32.1% absolute increase at 10 years). No interaction between p16-status and fractionation schedule was detected. Smoking negatively impacted outcome; in the p16-positive subgroup, never smokers had significantly better PFS than former/current smokers (HR = 0.49 [0.33-0.75], 24.2% survival benefit at 10 years). No predictive impact of p16-status on response to AFRT could be detected but the strong prognostic impact of p16-status was confirmed and especially p16-positive never smoking patients have superior outcome after RT. Copyright © 2017 Elsevier B.V. All rights reserved.
Driving with hemianopia: IV. Head scanning and detection at intersections in a simulator.
Bowers, Alex R; Ananyev, Egor; Mandel, Aaron J; Goldstein, Robert B; Peli, Eli
2014-03-13
Using a driving simulator, we examined the effects of homonymous hemianopia (HH) on head scanning behaviors at intersections and evaluated the role of inadequate head scanning in detection failures. Fourteen people with complete HH and without cognitive decline or visual neglect and 12 normally sighted (NV) current drivers participated. They drove in an urban environment following predetermined routes, which included multiple intersections. Head scanning behaviors were quantified at T-intersections (n = 32) with a stop or yield sign. Participants also performed a pedestrian detection task. The relationship between head scanning and detection was examined at 10 intersections. For HH drivers, the first scan was more likely to be toward the blind than the seeing hemifield. They also made a greater proportion of head scans overall to the blind side than did the NV drivers to the corresponding side (P = 0.003). However, head scan magnitudes of HH drivers were smaller than those of the NV group (P < 0.001). Drivers with HH had impaired detection of blind-side pedestrians due either to not scanning in the direction of the pedestrian or to an insufficient scan magnitude (left HH detected only 46% and right HH 8% at the extreme left and right of the intersection, respectively). Drivers with HH demonstrated compensatory head scan patterns, but not scan magnitudes. Inadequate scanning resulted in blind-side detection failures, which might place HH drivers at increased risk for collisions at intersections. Scanning training tailored to specific problem areas identified in this study might be beneficial.
2013-01-01
Background Socioeconomic inequalities in cancer mortality have been observed in different European countries and the US until the end of the 1990s, with changes over time in the magnitude of these inequalities and contrasted situations between countries. The aim of this study is to estimate relative and absolute educational differences in cancer mortality in France between 1999 and 2007, and to compare these inequalities with those reported during the 1990s. Methods Data from a representative sample including 1% of the French population were analysed. Educational differences among people aged 30–74 were quantified with hazard ratios and relative indices of inequality (RII) computed using Cox regression models as well as mortality rate difference and population attributable fraction. Results In the period 1999–2007, large relative inequalities were found among men for total cancer and smoking and/or alcohol related cancers mortality (lung, head and neck, oesophagus). Among women, educational differences were reported for total cancer, head and neck and uterus cancer mortality. No association was found between education and breast cancer mortality. Slight educational differences in colorectal cancer mortality were observed in men and women. For most frequent cancers, no change was observed in the magnitude of relative inequalities in mortality between the 1990s and the 2000s, although the RII for lung cancer increased both in men and women. Among women, a large increase in absolute inequalities in mortality was observed for all cancers combined, lung, head and neck and colorectal cancer. In contrast, among men, absolute inequalities in mortality decreased for all smoking and/or alcohol related cancers. Conclusion Although social inequalities in cancer mortality are still high among men, an encouraging trend is observed. Among women though, the situation regarding social inequalities is less favourable, mainly due to a health improvement limited to higher educated women. These inequalities may be expected to further increase in future years. PMID:24015917
Menvielle, Gwenn; Rey, Grégoire; Jougla, Eric; Luce, Danièle
2013-09-10
Socioeconomic inequalities in cancer mortality have been observed in different European countries and the US until the end of the 1990s, with changes over time in the magnitude of these inequalities and contrasted situations between countries. The aim of this study is to estimate relative and absolute educational differences in cancer mortality in France between 1999 and 2007, and to compare these inequalities with those reported during the 1990s. Data from a representative sample including 1% of the French population were analysed. Educational differences among people aged 30-74 were quantified with hazard ratios and relative indices of inequality (RII) computed using Cox regression models as well as mortality rate difference and population attributable fraction. In the period 1999-2007, large relative inequalities were found among men for total cancer and smoking and/or alcohol related cancers mortality (lung, head and neck, oesophagus). Among women, educational differences were reported for total cancer, head and neck and uterus cancer mortality. No association was found between education and breast cancer mortality. Slight educational differences in colorectal cancer mortality were observed in men and women. For most frequent cancers, no change was observed in the magnitude of relative inequalities in mortality between the 1990s and the 2000s, although the RII for lung cancer increased both in men and women. Among women, a large increase in absolute inequalities in mortality was observed for all cancers combined, lung, head and neck and colorectal cancer. In contrast, among men, absolute inequalities in mortality decreased for all smoking and/or alcohol related cancers. Although social inequalities in cancer mortality are still high among men, an encouraging trend is observed. Among women though, the situation regarding social inequalities is less favourable, mainly due to a health improvement limited to higher educated women. These inequalities may be expected to further increase in future years.
Pernik, Meribeth
1987-01-01
The sensitivity of a multilayer finite-difference regional flow model was tested by changing the calibrated values for five parameters in the steady-state model and one in the transient-state model. The parameters that changed under the steady-state condition were those that had been routinely adjusted during the calibration process as part of the effort to match pre-development potentiometric surfaces, and elements of the water budget. The tested steady-state parameters include: recharge, riverbed conductance, transmissivity, confining unit leakance, and boundary location. In the transient-state model, the storage coefficient was adjusted. The sensitivity of the model to changes in the calibrated values of these parameters was evaluated with respect to the simulated response of net base flow to the rivers, and the mean value of the absolute head residual. To provide a standard measurement of sensitivity from one parameter to another, the standard deviation of the absolute head residual was calculated. The steady-state model was shown to be most sensitive to changes in rates of recharge. When the recharge rate was held constant, the model was more sensitive to variations in transmissivity. Near the rivers, the riverbed conductance becomes the dominant parameter in controlling the heads. Changes in confining unit leakance had little effect on simulated base flow, but greatly affected head residuals. The model was relatively insensitive to changes in the location of no-flow boundaries and to moderate changes in the altitude of constant head boundaries. The storage coefficient was adjusted under transient conditions to illustrate the model 's sensitivity to changes in storativity. The model is less sensitive to an increase in storage coefficient than it is to a decrease in storage coefficient. As the storage coefficient decreased, the aquifer drawdown increases, the base flow decreased. The opposite response occurred when the storage coefficient was increased. (Author 's abstract)
Haefner, Matthias Felix; Giesel, Frederik Lars; Mattke, Matthias; Rath, Daniel; Wade, Moritz; Kuypers, Jacob; Preuss, Alan; Kauczor, Hans-Ulrich; Schenk, Jens-Peter; Debus, Juergen; Sterzing, Florian; Unterhinninghofen, Roland
2018-01-01
We developed a new approach to produce individual immobilization devices for the head based on MRI data and 3D printing technologies. The purpose of this study was to determine positioning accuracy with healthy volunteers. 3D MRI data of the head were acquired for 8 volunteers. In-house developed software processed the image data to generate a surface mesh model of the immobilization mask. After adding an interface for the couch, the fixation setup was materialized using a 3D printer with acrylonitrile butadiene styrene (ABS). Repeated MRI datasets (n=10) were acquired for all volunteers wearing their masks thus simulating a setup for multiple fractions. Using automatic image-to-image registration, displacements of the head were calculated relative to the first dataset (6 degrees of freedom). The production process has been described in detail. The absolute lateral (x), vertical (y) and longitudinal (z) translations ranged between −0.7 and 0.5 mm, −1.8 and 1.4 mm, and −1.6 and 2.4 mm, respectively. The absolute rotations for pitch (x), yaw (y) and roll (z) ranged between −0.9 and 0.8°, −0.5 and 1.1°, and −0.6 and 0.8°, respectively. The mean 3D displacement was 0.9 mm with a standard deviation (SD) of the systematic and random error of 0.2 mm and 0.5 mm, respectively. In conclusion, an almost entirely automated production process of 3D printed immobilization masks for the head derived from MRI data was established. A high level of setup accuracy was demonstrated in a volunteer cohort. Future research will have to focus on workflow optimization and clinical evaluation. PMID:29464087
NASA Astrophysics Data System (ADS)
Salguero, Francisco Javier; Arráns, Rafael; Atriana Palma, Bianey; Leal, Antonio
2010-03-01
The purpose of this paper is to assess the feasibility of delivering intensity- and energy-modulated electron radiation treatment (MERT) by a photon multileaf collimator (xMLC) and to evaluate the improvements obtained in shallow head and neck (HN) tumors. Four HN patient cases covering different clinical situations were planned by MERT, which used an in-house treatment planning system that utilized Monte Carlo dose calculation. The cases included one oronasal, two parotid and one middle ear tumors. The resulting dose-volume histograms were compared with those obtained from conventional photon and electron treatment techniques in our clinic, which included IMRT, electron beam and mixed beams, most of them using fixed-thickness bolus. Experimental verification was performed with plane-parallel ionization chambers for absolute dose verification, and a PTW ionization chamber array and radiochromic film for relative dosimetry. A MC-based treatment planning system for target with compromised volumes in depth and laterally has been validated. A quality assurance protocol for individual MERT plans was launched. Relative MC dose distributions showed a high agreement with film measurements and absolute ion chamber dose measurements performed at a reference point agreed with MC calculations within 2% in all cases. Clinically acceptable PTV coverage and organ-at-risk sparing were achieved by using the proposed MERT approach. MERT treatment plans, based on delivery of intensity-modulated electron beam using the xMLC, for superficial head and neck tumors, demonstrated comparable or improved PTV dose homogeneity with significantly lower dose to normal tissues. The clinical implementation of this technique will be able to offer a viable alternative for the treatment of shallow head and neck tumors.
Haefner, Matthias Felix; Giesel, Frederik Lars; Mattke, Matthias; Rath, Daniel; Wade, Moritz; Kuypers, Jacob; Preuss, Alan; Kauczor, Hans-Ulrich; Schenk, Jens-Peter; Debus, Juergen; Sterzing, Florian; Unterhinninghofen, Roland
2018-01-19
We developed a new approach to produce individual immobilization devices for the head based on MRI data and 3D printing technologies. The purpose of this study was to determine positioning accuracy with healthy volunteers. 3D MRI data of the head were acquired for 8 volunteers. In-house developed software processed the image data to generate a surface mesh model of the immobilization mask. After adding an interface for the couch, the fixation setup was materialized using a 3D printer with acrylonitrile butadiene styrene (ABS). Repeated MRI datasets (n=10) were acquired for all volunteers wearing their masks thus simulating a setup for multiple fractions. Using automatic image-to-image registration, displacements of the head were calculated relative to the first dataset (6 degrees of freedom). The production process has been described in detail. The absolute lateral (x), vertical (y) and longitudinal (z) translations ranged between -0.7 and 0.5 mm, -1.8 and 1.4 mm, and -1.6 and 2.4 mm, respectively. The absolute rotations for pitch (x), yaw (y) and roll (z) ranged between -0.9 and 0.8°, -0.5 and 1.1°, and -0.6 and 0.8°, respectively. The mean 3D displacement was 0.9 mm with a standard deviation (SD) of the systematic and random error of 0.2 mm and 0.5 mm, respectively. In conclusion, an almost entirely automated production process of 3D printed immobilization masks for the head derived from MRI data was established. A high level of setup accuracy was demonstrated in a volunteer cohort. Future research will have to focus on workflow optimization and clinical evaluation.
Kishan, Amar U; Cui, Jing; Wang, Pin-Chieh; Daly, Megan E; Purdy, James A; Chen, Allen M
2014-10-01
To quantify changes in gross tumour volume (GTV) between simulation and initiation of radiotherapy in patients with locally advanced malignancies of the lung and head/neck. Initial cone beam computed tomography (CT) scans from 12 patients with lung cancer and 12 with head/neck cancer (head and neck squamous cell carcinoma (HNSCC)) treated with intensity-modulated radiotherapy with image guidance were rigidly registered to the simulation CT scans. The GTV was demarcated on both scans. The relationship between percent GTV change and variables including time interval between simulation and start, tumour (T) stage, and absolute weight change was assessed. For lung cancer patients, the GTV increased a median of 35.06% (range, -16.63% to 229.97%) over a median interval of 13 days (range, 7-43), while for HNSCC patients, the median GTV increase was 16.04% (range, -8.03% to 47.41%) over 13 days (range, 7-40). These observed changes are statistically significant. The magnitude of this change was inversely associated with the size of the tumour on the simulation scan for lung cancer patients (P < 0.05). However, the observed changes in GTV did not correlate with the duration of the interval for either disease site. Similarly, T stage, absolute weight change and histologic type (the latter for lung cancer cases) did not correlate with degree of GTV change (P > 0.1). While the observed changes in GTV were moderate from the time of simulation to start of radiotherapy, these findings underscore the importance of image guidance for target localisation and verification, particularly for smaller tumours. Minimising the delay between simulation and treatment initiation may also be beneficial. © 2014 The Royal Australian and New Zealand College of Radiologists.
Goswami, Shyamaprosad; Das, Avijit Kumar; Manna, Abhishek; Maity, Anup Kumar; Saha, Partha; Quah, Ching Kheng; Fun, Hoong-Kun; Abdel-Aziz, Hatem A
2014-07-01
By employing the oxidation property of hypochlorite (OCl(-)), a novel rhodamine-based hydrazide of the chiral acid ((S)-(-)-2-pyrrolidone-5-carboxylic acid) (RHHP) was designed and synthesized for detection of OCl(-) absolutely in aqueous medium at nanomolar level. The structure of the chiral sensor was also proved by the X-ray crystallography. The bioactivity and the application of the probe for detection of OCl(-) in natural water system have been demonstrated. A plausible mechanism for oxidation of the sensor followed by hydrolysis is also proposed. The sensibility of the receptor toward OCl(-) was studied in absolute aqueous media, and the detection limit of hypochlorite-mediated oxidation to the receptor in nanomolar level makes this platform (RHHP) an ultrasensitive and unique system for OCl(-) oxidation.
Head Rotation Detection in Marmoset Monkeys
NASA Astrophysics Data System (ADS)
Simhadri, Sravanthi
Head movement is known to have the benefit of improving the accuracy of sound localization for humans and animals. Marmoset is a small bodied New World monkey species and it has become an emerging model for studying the auditory functions. This thesis aims to detect the horizontal and vertical rotation of head movement in marmoset monkeys. Experiments were conducted in a sound-attenuated acoustic chamber. Head movement of marmoset monkey was studied under various auditory and visual stimulation conditions. With increasing complexity, these conditions are (1) idle, (2) sound-alone, (3) sound and visual signals, and (4) alert signal by opening and closing of the chamber door. All of these conditions were tested with either house light on or off. Infra-red camera with a frame rate of 90 Hz was used to capture of the head movement of monkeys. To assist the signal detection, two circular markers were attached to the top of monkey head. The data analysis used an image-based marker detection scheme. Images were processed using the Computation Vision Toolbox in Matlab. The markers and their positions were detected using blob detection techniques. Based on the frame-by-frame information of marker positions, the angular position, velocity and acceleration were extracted in horizontal and vertical planes. Adaptive Otsu Thresholding, Kalman filtering and bound setting for marker properties were used to overcome a number of challenges encountered during this analysis, such as finding image segmentation threshold, continuously tracking markers during large head movement, and false alarm detection. The results show that the blob detection method together with Kalman filtering yielded better performances than other image based techniques like optical flow and SURF features .The median of the maximal head turn in the horizontal plane was in the range of 20 to 70 degrees and the median of the maximal velocity in horizontal plane was in the range of a few hundreds of degrees per second. In comparison, the natural alert signal -- door opening and closing -- evoked the faster head turns than other stimulus conditions. These results suggest that behaviorally relevant stimulus such as alert signals evoke faster head-turn responses in marmoset monkeys.
[Sequelae of severe craniocerebral injuries. An epidemiological study in the Canton of St. Gallen].
Annoni, J M; Beer, S; Kesselring, J
1991-02-16
Severe head injuries often lead to serious medical and socioeconomic sequelae. The incidence rate indicated in other studies shows a wide variation due to differences in selection criteria. Based upon an unselected population, the incidence of severe head injury was calculated and the surviving patients were interviewed and clinically examined 3 years after the accident in order to describe the course, rehabilitation and psychosocial sequelae after severe head injury. Retrospectively we collected 80 patients living in the canton of St. Gallen who had a severe head injury requiring hospitalization in 1987, indicating an incidence of 20 per 100,000 inhabitants. 22 (28%) of these patients died as a consequence of the head trauma. The best predictor was the Glasgow coma score at admission, which showed a highly significant direct correlation with survival rate. Regarding the degree of impairment of survivors the duration of posttraumatic amnesia was the best predictive parameter. Of the 45 patients controlled 3 years after the head trauma only 11% were severely impaired in daily activities. 79% of the patients who were gainfully employed before the accident were working full- or at least part-time. However, only 3 patients (7%) were absolutely free of symptoms. Most patients suffered from cognitive and emotional deficits. Based on an estimated incidence for minor head trauma of 174 per 100,000 inhabitants, a total annual incidence for all head traumas of 194 per 100,000 inhabitants is calculated, with severe head injury representing about 1/9 of all head injuries.
QTLs for heading date and plant height under multiple environments in rice.
Han, Zhongmin; Hu, Wei; Tan, Cong; Xing, Yongzhong
2017-02-01
Both heading date and plant height are important traits related to grain yield in rice. In this study, a recombinant inbred lines (RILs) population was used to map quantitative trait loci (QTLs) for both traits under 3 long-day (LD) environments and 1 short-day (SD) environment. A total of eight QTLs for heading date and three QTLs for plant height were detected by composite interval mapping under LD conditions. Additional one QTL for heading date and three QTLs for plant height were identified by Two-QTL model under LD conditions. Among them, major QTLs qHd7.1, qHd7.2 and qHd8 for heading date, and qPh1 and qPh7.1 for plant height were commonly detected. qHd7.1 and qHd7.2 were mapped to small regions of less than 1 cM. Genome position comparison of previously cloned genes with QTLs detected in this study revealed that qHd5 and qPh3.1 were two novel QTLs. The alleles of these QTLs increasing trait values were dispersed in both parents, which well explained the transgressive segregation observed in this population. In addition, the interaction between qHd7.1 and qHd8 was detected under all LD conditions. Multiple-QTL model analysis revealed that all QTLs and their interactions explained over 80% of heading date variation and 50% of plant height variation. Two heading date QTLs were detected under SD condition. Of them, qHd10 were commonly identified under LD condition. The difference in QTL detection between LD and SD conditions indicated most heading date QTLs are sensitive to photoperiod. These findings will benefit breeding design for heading date and plant height in rice.
Numbers Defy the Law of Large Numbers
ERIC Educational Resources Information Center
Falk, Ruma; Lann, Avital Lavie
2015-01-01
As the number of independent tosses of a fair coin grows, the rates of heads and tails tend to equality. This is misinterpreted by many students as being true also for the absolute numbers of the two outcomes, which, conversely, depart unboundedly from each other in the process. Eradicating that misconception, as by coin-tossing experiments,…
ERIC Educational Resources Information Center
Giuliani, Fabienne; Favrod, Jerome; Grasset, Francois; Schenk, Francoise
2011-01-01
Using head-mounted eye tracker material, we assessed spatial recognition abilities (e.g., reaction to object permutation, removal or replacement with a new object) in participants with intellectual disabilities. The "Intellectual Disabilities (ID)" group (n = 40) obtained a score totalling a 93.7% success rate, whereas the "Normal Control" group…
Effect of Viewing Plane on Perceived Distances in Real and Virtual Environments
ERIC Educational Resources Information Center
Geuss, Michael N.; Stefanucci, Jeanine K.; Creem-Regehr, Sarah H.; Thompson, William B.
2012-01-01
Three experiments examined perceived absolute distance in a head-mounted display virtual environment (HMD-VE) and a matched real-world environment, as a function of the type and orientation of the distance viewed. In Experiment 1, participants turned and walked, without vision, a distance to match the viewed interval for both egocentric…
Eddy-Current Detection of Weak Bolt Heads
NASA Technical Reports Server (NTRS)
Messina, C. P.
1987-01-01
Electronic test identifies flawed units passing hardness tests. Eddy-current test detects weakness in head-to-shank junctions of 1/4-28 cup-washer lock bolts. Developed for alloy A286 steel bolts in Space Shuttle main engine fuel turbo-pump. Test examines full volume of head, including head-to-shank transition and nondestructively screens out potentially defective units. Test adapts to any other alloys.
Qian, Zhi-Ming; Wang, Shuo Hong; Cheng, Xi En; Chen, Yan Qiu
2016-06-23
Fish tracking is an important step for video based analysis of fish behavior. Due to severe body deformation and mutual occlusion of multiple swimming fish, accurate and robust fish tracking from video image sequence is a highly challenging problem. The current tracking methods based on motion information are not accurate and robust enough to track the waving body and handle occlusion. In order to better overcome these problems, we propose a multiple fish tracking method based on fish head detection. The shape and gray scale characteristics of the fish image are employed to locate the fish head position. For each detected fish head, we utilize the gray distribution of the head region to estimate the fish head direction. Both the position and direction information from fish detection are then combined to build a cost function of fish swimming. Based on the cost function, global optimization method can be applied to associate the target between consecutive frames. Results show that our method can accurately detect the position and direction information of fish head, and has a good tracking performance for dozens of fish. The proposed method can successfully obtain the motion trajectories for dozens of fish so as to provide more precise data to accommodate systematic analysis of fish behavior.
van Dommelen, Paula; Deurloo, Jacqueline A; Gooskens, Rob H; Verkerk, Paul H
2015-04-01
Increased head circumference is often the first and main sign leading to the diagnosis of hydrocephalus. Our aim is to investigate the diagnostic accuracy of referral criteria for head circumference to detect hydrocephalus in the first year of life. A reference group with longitudinal head circumference data (n = 1938) was obtained from the Social Medical Survey of Children Attending Child Health Clinics study. The case group comprised infants with hydrocephalus treated in a tertiary pediatric hospital who had not already been detected during pregnancy (n = 125). Head circumference data were available for 43 patients. Head circumference data were standardized according to gestational age-specific references. Sensitivity and specificity of a very large head circumference (>2.5 standard deviations on the growth chart) were, respectively, 72.1% (95% confidence interval [CI]: 56.3-84.7) and 97.1% (95% CI:96.2-97.8). These figures were, respectively, 74.4% (95% CI: 58.8-86.5) and 93.0% (95% CI:91.8-94.1) for a large head circumference (>2.0 standard deviation), and 76.7% (95% CI:61.4-88.2) and 96.5% (95% CI:95.6-97.3) for a very large head circumference and/or a very large (>2.5 standard deviation) progressive growth of head circumference. A very large head circumference and/or a very large progressive growth of head circumference shows the best diagnostic accuracy to detect hydrocephalus at an early stage. Gestational age-specific growth charts are recommended. Further improvements may be possible by taking into account parental head circumference. Copyright © 2015 Elsevier Inc. All rights reserved.
Assessment of a head support system to prevent pediatric out-of-position: an observational study.
Lopez-Valdes, Francisco J; Forman, Jason L; Ash, Joseph H; Kent, Richard; Alba, Juan J; Segui-Gomez, Maria
Head injuries are the most common severe injuries sustained by pediatric occupants in road traffic crashes. Preventing children from adopting positions that can result in an increased injury risk due to unfavorable interactions with the restraints is fundamental. The objective of this paper was to assess the effect of a head support system (SS) on the lateral position of the head, the vertical position of the sternum and the shoulder belt fit. Thirty pediatric rear-seat passengers were exposed to two 75-minute trials. Volunteers were restrained by a three-point belt and, if needed, used the appropriate child restraint system for their anthropometry (high-back booster, low-back booster, no booster). A case crossover study was designed in which the volunteers used the head support system (SS) during one of the trials, acting as their own controls (No SS) in the other. Compared to the control group, the head support reduced significantly the 90(th) percentile value of the absolute value of the relative lateral motion of the head, regardless of the restraint used. The system also reduced the maximum downward position of the sternal notch within the low-back booster group. As for the belt fit, the use of the head support improved significantly the position of the shoulder belt on the occupant in the low-back booster and in the no booster groups.
Assessment of a head support system to prevent pediatric out-of-position: an observational study
Lopez-Valdes, Francisco J.; Forman, Jason L.; Ash, Joseph H.; Kent, Richard; Alba, Juan J.; Segui-Gomez, Maria
2013-01-01
Head injuries are the most common severe injuries sustained by pediatric occupants in road traffic crashes. Preventing children from adopting positions that can result in an increased injury risk due to unfavorable interactions with the restraints is fundamental. The objective of this paper was to assess the effect of a head support system (SS) on the lateral position of the head, the vertical position of the sternum and the shoulder belt fit. Thirty pediatric rear-seat passengers were exposed to two 75-minute trials. Volunteers were restrained by a three-point belt and, if needed, used the appropriate child restraint system for their anthropometry (high-back booster, low-back booster, no booster). A case crossover study was designed in which the volunteers used the head support system (SS) during one of the trials, acting as their own controls (No SS) in the other. Compared to the control group, the head support reduced significantly the 90th percentile value of the absolute value of the relative lateral motion of the head, regardless of the restraint used. The system also reduced the maximum downward position of the sternal notch within the low-back booster group. As for the belt fit, the use of the head support improved significantly the position of the shoulder belt on the occupant in the low-back booster and in the no booster groups. PMID:24406966
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, S; Tianjin University, Tianjin; Hara, W
Purpose: MRI has a number of advantages over CT as a primary modality for radiation treatment planning (RTP). However, one key bottleneck problem still remains, which is the lack of electron density information in MRI. In the work, a reliable method to map electron density is developed by leveraging the differential contrast of multi-parametric MRI. Methods: We propose a probabilistic Bayesian approach for electron density mapping based on T1 and T2-weighted MRI, using multiple patients as atlases. For each voxel, we compute two conditional probabilities: (1) electron density given its image intensity on T1 and T2-weighted MR images, and (2)more » electron density given its geometric location in a reference anatomy. The two sources of information (image intensity and spatial location) are combined into a unifying posterior probability density function using the Bayesian formalism. The mean value of the posterior probability density function provides the estimated electron density. Results: We evaluated the method on 10 head and neck patients and performed leave-one-out cross validation (9 patients as atlases and remaining 1 as test). The proposed method significantly reduced the errors in electron density estimation, with a mean absolute HU error of 138, compared with 193 for the T1-weighted intensity approach and 261 without density correction. For bone detection (HU>200), the proposed method had an accuracy of 84% and a sensitivity of 73% at specificity of 90% (AUC = 87%). In comparison, the AUC for bone detection is 73% and 50% using the intensity approach and without density correction, respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection based on multi-parametric MRI of the head with highly heterogeneous anatomy. This could allow for accurate dose calculation and reference image generation for patient setup in MRI-based radiation treatment planning.« less
NASA Astrophysics Data System (ADS)
Peko, B. L.; Stephen, T. M.
2000-12-01
Measured absolute detection efficiencies are presented for H, H - and H n+ ( n=1,2,3) impacting a commercially available, dual multichannel plate (MCP) electron multiplier at kinetic energies ranging from 30 to 1000 eV. Measurements involving isotopic substitutions (D, D -, D n+) and Ar + are also presented. In addition, atomic hydrogen detection efficiencies relative to those of H + and H - are given, as they may have a more universal application. For the three charge states, H, H + and H -, the absolute detection efficiencies are markedly different at low energies and converge to a nearly uniform value of ˜70% with increasing projectile energy. The energy dependence is strongest for H +, varying nearly three orders of magnitude over the energy range studied, and weakest for H -, varying by less than one order of magnitude. In general, for the low energy positive ions at a given energy, the lighter the incident particle mass, the greater the probability of its detection.
Heo, Gyeong Mi; Kim, Mi Hee; Kim, Jin Hwan; Rho, Young Soo; Shin, Woon Geon
2016-07-25
In head and neck squamous cell carcinoma, second primary gastrointestinal tumors are not uncommon. However, it is unclear whether a screening endoscopy is needed for detecting gastrointestinal neoplasm in patients with head and neck cancer. Therefore, we analyzed the prevalence and independent risk factors for second primary gastrointestinal neoplasm in head and neck squamous cell carcinoma. A consecutive series of 328 patients with primary head and neck squamous cell carcinoma that underwent esophagogastroduodenoscopy or colonoscopy were included using our registry. An age- and sex-matched group of 328 control subjects was enrolled. We assessed risk factors of synchronous gastrointestinal cancer. The prevalence of esophageal cancer with head and neck squamous cell carcinoma was significantly higher than that of the control group (1.5% vs. 0.0%, p=0.011). An age of 54 years or more (OR, 1.033; 95% CI, 1.008-1.059; p=0.009) and male gender (OR, 4.974; 95% CI, 1.648-15.013; p=0.004) were risk factors for concomitant colorectal cancer or adenomas in the head and neck squamous cell carcinoma patients. Preoperative colonoscopy can be recommended for detecting synchronous second primary colorectal lesions in head and neck squamous cell carcinoma patients with male sex regardless of age, and esophagogastroduodenoscopy is necessary in all head and neck squamous cell carcinoma patients for detecting esophageal cancer.
Diagnostic Performance of Ultrafast Brain MRI for Evaluation of Abusive Head Trauma.
Kralik, S F; Yasrebi, M; Supakul, N; Lin, C; Netter, L G; Hicks, R A; Hibbard, R A; Ackerman, L L; Harris, M L; Ho, C Y
2017-04-01
MR imaging with sedation is commonly used to detect intracranial traumatic pathology in the pediatric population. Our purpose was to compare nonsedated ultrafast MR imaging, noncontrast head CT, and standard MR imaging for the detection of intracranial trauma in patients with potential abusive head trauma. A prospective study was performed in 24 pediatric patients who were evaluated for potential abusive head trauma. All patients received noncontrast head CT, ultrafast brain MR imaging without sedation, and standard MR imaging with general anesthesia or an immobilizer, sequentially. Two pediatric neuroradiologists independently reviewed each technique blinded to other modalities for intracranial trauma. We performed interreader agreement and consensus interpretation for standard MR imaging as the criterion standard. Diagnostic accuracy was calculated for ultrafast MR imaging, noncontrast head CT, and combined ultrafast MR imaging and noncontrast head CT. Interreader agreement was moderate for ultrafast MR imaging (κ = 0.42), substantial for noncontrast head CT (κ = 0.63), and nearly perfect for standard MR imaging (κ = 0.86). Forty-two percent of patients had discrepancies between ultrafast MR imaging and standard MR imaging, which included detection of subarachnoid hemorrhage and subdural hemorrhage. Sensitivity, specificity, and positive and negative predictive values were obtained for any traumatic pathology for each examination: ultrafast MR imaging (50%, 100%, 100%, 31%), noncontrast head CT (25%, 100%, 100%, 21%), and a combination of ultrafast MR imaging and noncontrast head CT (60%, 100%, 100%, 33%). Ultrafast MR imaging was more sensitive than noncontrast head CT for the detection of intraparenchymal hemorrhage ( P = .03), and the combination of ultrafast MR imaging and noncontrast head CT was more sensitive than noncontrast head CT alone for intracranial trauma ( P = .02). In abusive head trauma, ultrafast MR imaging, even combined with noncontrast head CT, demonstrated low sensitivity compared with standard MR imaging for intracranial traumatic pathology, which may limit its utility in this patient population. © 2017 by American Journal of Neuroradiology.
A primitive study on unsupervised anomaly detection with an autoencoder in emergency head CT volumes
NASA Astrophysics Data System (ADS)
Sato, Daisuke; Hanaoka, Shouhei; Nomura, Yukihiro; Takenaga, Tomomi; Miki, Soichiro; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu
2018-02-01
Purpose: The target disorders of emergency head CT are wide-ranging. Therefore, people working in an emergency department desire a computer-aided detection system for general disorders. In this study, we proposed an unsupervised anomaly detection method in emergency head CT using an autoencoder and evaluated the anomaly detection performance of our method in emergency head CT. Methods: We used a 3D convolutional autoencoder (3D-CAE), which contains 11 layers in the convolution block and 6 layers in the deconvolution block. In the training phase, we trained the 3D-CAE using 10,000 3D patches extracted from 50 normal cases. In the test phase, we calculated abnormalities of each voxel in 38 emergency head CT volumes (22 abnormal cases and 16 normal cases) for evaluation and evaluated the likelihood of lesion existence. Results: Our method achieved a sensitivity of 68% and a specificity of 88%, with an area under the curve of the receiver operating characteristic curve of 0.87. It shows that this method has a moderate accuracy to distinguish normal CT cases to abnormal ones. Conclusion: Our method has potentialities for anomaly detection in emergency head CT.
Absolute charge calibration of scintillating screens for relativistic electron detection
NASA Astrophysics Data System (ADS)
Buck, A.; Zeil, K.; Popp, A.; Schmid, K.; Jochmann, A.; Kraft, S. D.; Hidding, B.; Kudyakov, T.; Sears, C. M. S.; Veisz, L.; Karsch, S.; Pawelke, J.; Sauerbrey, R.; Cowan, T.; Krausz, F.; Schramm, U.
2010-03-01
We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm2. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm2 was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.
Halberstadt, Adam L; Geyer, Mark A
2013-06-01
The head-twitch response (HTR) is a rapid side-to-side rotational head movement that occurs in rats and mice after administration of serotonergic hallucinogens and other 5-HT2A agonists. The HTR is widely used as a behavioral assay for 5-HT2A activation and to probe for interactions between the 5-HT2A receptor and other transmitter systems. High-speed video recordings were used to analyze the head movement that occurs during head twitches in C57BL/6J mice. Experiments were also conducted in C57BL/6J mice to determine whether a head-mounted magnet and a magnetometer coil could be used to detect the HTR induced by serotonergic hallucinations based on the dynamics of the response. Head movement during the HTR was highly rhythmic and occurred within a specific frequency range (mean head movement frequency of 90.3 Hz). Head twitches produced wave-like oscillations of magnetometer coil voltage that matched the frequency of head movement during the response. The magnetometer coil detected the HTR induced by the serotonergic hallucinogens 2,5-dimethoxy-4-iodoamphetamine (DOI; 0.25, 0.5, and 1.0 mg/kg, i.p.) and lysergic acid diethylamide (LSD; 0.05, 0.1, 0.2, and 0.4 mg/kg, i.p.) with extremely high sensitivity and specificity. Magnetometer coil recordings demonstrated that the non-hallucinogenic compounds (+)-amphetamine (2.5 and 5.0 mg/kg, i.p.) and lisuride (0.8, 1.6, and 3.2 mg/kg, i.p.) did not induce the HTR. These studies confirm that a magnetometer coil can be used to detect the HTR induced by hallucinogens. The use of magnetometer-based HTR detection provides a high-throughput, semi-automated assay for this behavior, and offers several advantages over traditional assessment methods.
Bell, Zane W.
2000-01-01
A sensor for simultaneously detecting neutrons and ionizing electromagnetic radiation comprising: a sensor for the detection of gamma radiation, the sensor defining a sensing head; the sensor further defining an output end in communication with the sensing head; and an exterior neutron-sensitive material configured to form around the sensing head; wherein the neutron-sensitive material, subsequent to the capture of the neutron, fissions into an alpha-particle and a .sup.7 Li ion that is in a first excited state in a majority of the fissions, the first excited state decaying via the emission of a single gamma ray at 478 keV which can in turn be detected by the sensing head; and wherein the sensing head can also detect the ionizing electromagnetic radiation from an incident radiation field without significant interference from the neutron-sensitive material. A method for simultaneously detecting neutrons and ionizing electromagnetic radiation comprising the steps of: providing a gamma ray sensitive detector comprising a sensing head and an output end; conforming an exterior neutron-sensitive material configured to form around the sensing head of the detector; capturing neutrons by the sensing head causing the neutron-sensitive material to fission into an alpha-particle and a .sup.7 Li ion that is in a first excited state in a majority of the fissions, the state decaying via the emission of a single gamma ray at 478 keV; sensing gamma rays entering the detector through the neutron-sensitive material; and producing an output through a readout device coupled to the output end; wherein the detector provides an output which is proportional to the energy of the absorbed ionizing electromagnetic radiation.
Guilford, Tim; Taylor, Graham K.
2014-01-01
Many animals, and birds in particular, are thought to use directional information from the sun in the form of a time-compensated sun compass, with predictably deviated orientation under clock shift being regarded as the litmus test of this. We suggest that this paradigm obscures a number of other ways in which solar-derived information could be important in animal orientation. We distinguish between the known use of the sun's azimuth to provide absolute geographical direction (compass mechanism) and its possible use to detect changes in heading (heading indicator mechanism). Just as in an aircraft, these two kinds of information may be provided by separate mechanisms and used for different functions, for example for navigation versus steering. We also argue that although a solar compass must be time-referenced to account for the sun's apparent diurnal movement, this need not entail full time compensation. This is because animals might also use time-dependent solar information in an associatively acquired, and hence time-limited, way. Furthermore, we show that a solar heading indicator, when used on a sufficiently short timescale, need not require time compensation at all. Finally, we suggest that solar-derived cues, such as shadows, could also be involved in navigation in ways that depend explicitly upon position, and are therefore not strictly compass-related. This could include giving directionality to landmarks, or acting as time-dependent landmarks involved in place recognition. We conclude that clock shift experiments alone are neither necessary nor sufficient to identify the occurrence of all conceivable uses of solar information in animal orientation, so that a predictable response to clock shift should not be regarded as an acid test of the use of solar information in navigation. PMID:25389374
NREL's Solar Radiation Research Laboratory Offers a Mesa-Top Home for
measurements of a group of six absolute cavity radiometers. The standard has been in use since 1980, and is . NREL organizers such as Principal Scientist and Metrology Group Manager Ibrahim Reda, who heads up the presence. "We're still keeping in his footsteps. He's the one who mentored everyone here," Reda
The Absolute Spectrum Polarimeter (ASP)
NASA Technical Reports Server (NTRS)
Kogut, A. J.
2010-01-01
The Absolute Spectrum Polarimeter (ASP) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from 30 GHz to 5 THz. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much greater than 1O(raised to the power of { -3}) and Compton distortion y < 10 (raised to the power of{-6}). We describe the ASP instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.
Method For Detecting The Presence Of A Ferromagnetic Object
Roybal, Lyle G.
2000-11-21
A method for detecting a presence or an absence of a ferromagnetic object within a sensing area may comprise the steps of sensing, during a sample time, a magnetic field adjacent the sensing area; producing surveillance data representative of the sensed magnetic field; determining an absolute value difference between a maximum datum and a minimum datum comprising the surveillance data; and determining whether the absolute value difference has a positive or negative sign. The absolute value difference and the corresponding positive or negative sign thereof forms a representative surveillance datum that is indicative of the presence or absence in the sensing area of the ferromagnetic material.
Hawk Eyes II: Diurnal Raptors Differ in Head Movement Strategies When Scanning from Perches
O'Rourke, Colleen T.; Pitlik, Todd; Hoover, Melissa; Fernández-Juricic, Esteban
2010-01-01
Background Relatively little is known about the degree of inter-specific variability in visual scanning strategies in species with laterally placed eyes (e.g., birds). This is relevant because many species detect prey while perching; therefore, head movement behavior may be an indicator of prey detection rate, a central parameter in foraging models. We studied head movement strategies in three diurnal raptors belonging to the Accipitridae and Falconidae families. Methodology/Principal Findings We used behavioral recording of individuals under field and captive conditions to calculate the rate of two types of head movements and the interval between consecutive head movements. Cooper's Hawks had the highest rate of regular head movements, which can facilitate tracking prey items in the visually cluttered environment they inhabit (e.g., forested habitats). On the other hand, Red-tailed Hawks showed long intervals between consecutive head movements, which is consistent with prey searching in less visually obstructed environments (e.g., open habitats) and with detecting prey movement from a distance with their central foveae. Finally, American Kestrels have the highest rates of translational head movements (vertical or frontal displacements of the head keeping the bill in the same direction), which have been associated with depth perception through motion parallax. Higher translational head movement rates may be a strategy to compensate for the reduced degree of eye movement of this species. Conclusions Cooper's Hawks, Red-tailed Hawks, and American Kestrels use both regular and translational head movements, but to different extents. We conclude that these diurnal raptors have species-specific strategies to gather visual information while perching. These strategies may optimize prey search and detection with different visual systems in habitat types with different degrees of visual obstruction. PMID:20877650
Hawk eyes II: diurnal raptors differ in head movement strategies when scanning from perches.
O'Rourke, Colleen T; Pitlik, Todd; Hoover, Melissa; Fernández-Juricic, Esteban
2010-09-22
Relatively little is known about the degree of inter-specific variability in visual scanning strategies in species with laterally placed eyes (e.g., birds). This is relevant because many species detect prey while perching; therefore, head movement behavior may be an indicator of prey detection rate, a central parameter in foraging models. We studied head movement strategies in three diurnal raptors belonging to the Accipitridae and Falconidae families. We used behavioral recording of individuals under field and captive conditions to calculate the rate of two types of head movements and the interval between consecutive head movements. Cooper's Hawks had the highest rate of regular head movements, which can facilitate tracking prey items in the visually cluttered environment they inhabit (e.g., forested habitats). On the other hand, Red-tailed Hawks showed long intervals between consecutive head movements, which is consistent with prey searching in less visually obstructed environments (e.g., open habitats) and with detecting prey movement from a distance with their central foveae. Finally, American Kestrels have the highest rates of translational head movements (vertical or frontal displacements of the head keeping the bill in the same direction), which have been associated with depth perception through motion parallax. Higher translational head movement rates may be a strategy to compensate for the reduced degree of eye movement of this species. Cooper's Hawks, Red-tailed Hawks, and American Kestrels use both regular and translational head movements, but to different extents. We conclude that these diurnal raptors have species-specific strategies to gather visual information while perching. These strategies may optimize prey search and detection with different visual systems in habitat types with different degrees of visual obstruction.
Intersexual chemo-sensation in a “visually-oriented” lizard, Anolis sagrei
Driessens, Tess; Van Damme, Raoul
2016-01-01
While the conspicuous visual displays of anoles have been studied in great depth, the possibility that these lizards may also interact through chemical signalling has received hardly any consideration. In this study, we observed the behaviour of male brown anoles (Anolis sagrei) when introduced into an environment previously inhabited by female conspecifics, and compared it to when they were introduced into an untreated environment. The males in our tests exhibited significantly more elaborate display behaviour (i.e., greater number of dewlap extensions and head-nods) and a significantly greater number of tongue extrusions while in the cage formerly occupied by females than when placed in the untreated, control cage. The absolute numbers of tongue extrusions, however, were relatively low in comparison to average tongue-flick rates of ‘true’ chemically-oriented lizards. Our results strongly suggest that the males were capable of detecting chemical cues left behind by the females. These observations provide the first evidence of intersexual chemo-sensation in an anole lizard. PMID:27069809
Detection of Sound Image Movement During Horizontal Head Rotation
Ohba, Kagesho; Iwaya, Yukio; Suzuki, Yôiti
2016-01-01
Movement detection for a virtual sound source was measured during the listener’s horizontal head rotation. Listeners were instructed to do head rotation at a given speed. A trial consisted of two intervals. During an interval, a virtual sound source was presented 60° to the right or left of the listener, who was instructed to rotate the head to face the sound image position. Then in one of a pair of intervals, the sound position was moved slightly in the middle of the rotation. Listeners were asked to judge the interval in a trial during which the sound stimuli moved. Results suggest that detection thresholds are higher when listeners do head rotation. Moreover, this effect was found to be independent of the rotation velocity. PMID:27698993
A Reward-Based Behavioral Platform to Measure Neural Activity during Head-Fixed Behavior.
Micallef, Andrew H; Takahashi, Naoya; Larkum, Matthew E; Palmer, Lucy M
2017-01-01
Understanding the neural computations that contribute to behavior requires recording from neurons while an animal is behaving. This is not an easy task as most subcellular recording techniques require absolute head stability. The Go/No-Go sensory task is a powerful decision-driven task that enables an animal to report a binary decision during head-fixation. Here we discuss how to set up an Ardunio and Python based platform system to control a Go/No-Go sensory behavior paradigm. Using an Arduino micro-controller and Python-based custom written program, a reward can be delivered to the animal depending on the decision reported. We discuss the various components required to build the behavioral apparatus that can control and report such a sensory stimulus paradigm. This system enables the end user to control the behavioral testing in real-time and therefore it provides a strong custom-made platform for probing the neural basis of behavior.
Zviagin, V N; Galitskaia, O I; Negasheva, M A
2012-01-01
We have determined absolute dimensions of the head and the relationship between the dimensions of its selected parts. The study enrolled adult subjects (mostly of Russian ethnicity) at the age from 17 to 22 years (1108 men and 1153 women). We calculated the normal values for the estimation of real dimensional characteristics and the frequency of their occurrence in the population. The proposed approach makes it possible to reliably identify the dimensional features of human appearance in terms of the quantitative verbal description (categories 1-5) and to reveal its most characteristic features. The results of this biometric study of the heads of unrecognized corpses obtained by the specially developed technology may be used in operational and search investigations, in the procedure of corpse identification, and forensic medical personality identification of a missing subject.
The IBM HeadTracking Pointer: improvements in vision-based pointer control.
Kjeldsen, Rick
2008-07-01
Vision-based head trackers have been around for some years and are even beginning to be commercialized, but problems remain with respect to usability. Users without the ability to use traditional pointing devices--the intended audience of such systems--have no alternative if the automatic bootstrapping process fails. There is room for improvement in face tracking, and the pointer movement dynamics do not support accurate and efficient pointing. This paper describes the IBM HeadTracking Pointer, a system which attempts to directly address some of these issues. Head gestures are used to provide the end user a greater level of autonomous control over the system. A novel face-tracking algorithm reduces drift under variable lighting conditions, allowing the use of absolute, rather than relative, pointer positioning. Most importantly, the pointer dynamics have been designed to take into account the constraints of head-based pointing, with a non-linear gain which allows stability in fine pointer movement, high speed on long transitions and adjustability to support users with different movement dynamics. User studies have identified some difficulties with training the system and some characteristics of the pointer motion that take time to get used to, but also good user feedback and very promising performance results.
Hagiwara, Akifumi; Warntjes, Marcel; Hori, Masaaki; Andica, Christina; Nakazawa, Misaki; Kumamaru, Kanako Kunishima; Abe, Osamu; Aoki, Shigeki
2017-01-01
Abstract Conventional magnetic resonance images are usually evaluated using the image signal contrast between tissues and not based on their absolute signal intensities. Quantification of tissue parameters, such as relaxation rates and proton density, would provide an absolute scale; however, these methods have mainly been performed in a research setting. The development of rapid quantification, with scan times in the order of 6 minutes for full head coverage, has provided the prerequisites for clinical use. The aim of this review article was to introduce a specific quantification method and synthesis of contrast-weighted images based on the acquired absolute values, and to present automatic segmentation of brain tissues and measurement of myelin based on the quantitative values, along with application of these techniques to various brain diseases. The entire technique is referred to as “SyMRI” in this review. SyMRI has shown promising results in previous studies when used for multiple sclerosis, brain metastases, Sturge-Weber syndrome, idiopathic normal pressure hydrocephalus, meningitis, and postmortem imaging. PMID:28257339
Halberstadt, Adam L.; Geyer, Mark A.
2013-01-01
Rationale The head-twitch response (HTR) is a rapid side-to-side rotational head movement that occurs in rats and mice after administration of serotonergic hallucinogens and other 5-HT2A agonists. The HTR is widely used as a behavioral assay for 5-HT2A activation and to probe for interactions between the 5-HT2A receptor and other transmitter systems. Objective High-speed video recordings were used to analyze the head movement that occurs during head twitches in C57BL/6J mice. Experiments were also conducted in C57BL/6J mice to determine whether a head-mounted magnet and a magnetometer coil could be used to detect the HTR induced by serotonergic hallucinations based on the dynamics of the response. Results Head movement during the HTR was highly rhythmic and occurred within a specific frequency range (mean reciprocation frequency of 90.3 Hz). Head twitches produced wave-like oscillations of magnetometer coil voltage that matched the frequency of head movement during the response. The magnetometer coil detected the HTR induced by the serotonergic hallucinogens 2,5-dimethoxy-4-iodoamphetamine (DOI; 0.25, 0.5, and 1.0 mg/kg, IP) and lysergic acid diethylamide (LSD; 0.05, 0.1, 0.2, and 0.4 mg/kg, IP) with extremely high sensitivity and specificity. Magnetometer coil recordings demonstrated that the non-hallucinogenic compounds (+)-amphetamine (2.5 and 5.0 mg/kg, IP) and lisuride (0.8, 1.6, and 3.2 mg/kg, IP) did not induce the HTR. Conclusions These studies confirm that a magnetometer coil can be used to detect the HTR induced by hallucinogens. The use of magnetometer-based HTR detection provides a high-throughput, semi-automated assay for this behavior, and offers several advantages over traditional assessment methods. PMID:23407781
NASA Astrophysics Data System (ADS)
Lu, Wei; Tan, Jinglu; Floyd, Randall C.
2005-04-01
Object detection in ultrasound fetal images is a challenging task for the relatively low resolution and low signal-to-noise ratio. A direct inverse randomized Hough transform (DIRHT) is developed for filtering and detecting incomplete curves in images with strong noise. The DIRHT combines the advantages of both the inverse and the randomized Hough transforms. In the reverse image, curves are highlighted while a large number of unrelated pixels are removed, demonstrating a "curve-pass filtering" effect. Curves are detected by iteratively applying the DIRHT to the filtered image. The DIRHT was applied to head detection and measurement of the biparietal diameter (BPD) and head circumference (HC). No user input or geometric properties of the head were required for the detection. The detection and measurement took 2 seconds for each image on a PC. The inter-run variations and the differences between the automatic measurements and sonographers" manual measurements were small compared with published inter-observer variations. The results demonstrated that the automatic measurements were consistent and accurate. This method provides a valuable tool for fetal examinations.
Toward an Understanding of the Role of Relational Trust for New Heads of Independent Schools
ERIC Educational Resources Information Center
Batiste, Harold Eugene, III
2012-01-01
Within the context of schools, it can be argued that trust is a complex absolute necessity if students are to be successful learners; if educators are to be successful facilitators and champions of learning; if the staff is to be successful providers of educational support; if parents, guardians, and families are to be successful partners with the…
NASA Astrophysics Data System (ADS)
Chiu, Joshua; Pierce, Marlon; Braunstein, Steve E.; Theodosopoulos, Philip V.; McDermott, Michael W.; Sneed, Penny K.; Ma, Lijun
2016-10-01
Sharp dose fall-off is the hallmark of brain radiosurgery for the purpose of delivering high dose radiation to the target while minimizing peripheral dose to regional normal brain tissue. In this study, a technique was developed to enhance the peripheral dose gradient by magnifying the total number of beams focused toward each isocenter through pre-programmed patient head tilting. This technique was tested in clinical settings on a dedicated brain radiosurgical system (GKPFX, Gamma Knife Perfexion, Elekta Oncology) by comparing dosimetry as well as delivery efficiency for 20 radiosurgical cases previously treated with the system. The 3-fold beam number enhancement (BNE) treatment plans were found to produce nearly identical target volume coverage (absolute value < 0.5%, P > 0.2) and dose conformity (BNE CI = 1.41 ± 0.22 versus 1.41 ± 0.11, P > 0.99) as the original treatment plans. The total beam-on time for the 3-fold BNE treatment plans were also found to be comparable (<0.5 min or 2%) with those of the original treatment plans for all the cases. However, BNE treatment plans significantly improved the mean gradient index (BNE GI = 2.94 ± 0.27 versus original GI = 2.98 ± 0.28 P < 0.0001) and low-level isodose volumes, e.g. 20-50% prescribed isodose volumes, by 1.7%-3.9% (P < 0.03). With further 4-5-fold increase in the total number of beams, the absolute gradient index can decrease by as much as -0.5 in absolute value or -20% for a treatment. In conclusion, BNE via patient head tilt has been demonstrated to be a clinically suitable and efficient technique for physically sharpening the peripheral dose gradient for brain radiosurgery. This work was presented in part at the 2015 ISRS Congress in Yokohama Japan.
Than, Leslie Thian Lung; Chong, Pei Pei; Ng, Kee Peng; Seow, Heng Fong
2015-01-01
The number of invasive candidiasis cases has risen especially with an increase in the number of immunosuppressed and immunocom promised patients. The early detection of Candida species which is specific and sensitive is important in determining the correct administration of antifungal drugs to patients. This study aims to develop a method for the detection, identification and quantitation of medically important Candida species through quantitative polymerase chain reaction (qPCR). The isocitrate lyase (ICL) gene which is not found in mammals was chosen as the target gene of real-time PCR. Absolute quantitation of the gene copy number was achieved by constructing the plasmid containing the ICL gene which is used to generate standard curve. Twenty fungal species, two bacterial species and human DNA were tested to check the specificity of the detection method. All eight Candida species were successfully detected, identified and quantitated based on the ICL gene. A seven-log range of the gene copy number and a minimum detection limit of 10(3) copies were achieved. A one-tube absolute quantification real-time PCR that differentiates medically important Candida species via individual unique melting temperature was achieved. Analytical sensitivity and specificity were not compromised.
A Comparison of Blood Metal Ions in Total Hip Arthroplasty Using Metal and Ceramic Heads.
White, Peter B; Meftah, Morteza; Ranawat, Amar S; Ranawat, Chitranjan S
2016-10-01
In recent time, metal ion debris and adverse local tissue reaction have reemerged as an area of clinical concern with the use of large femoral heads after total hip arthroplasty (THA). Between June 2014 and January 2015, 60 patients with a noncemented THA using a titanium (titanium, molybdenum, zirconium, and iron alloy) femoral stem and a V40 trunnion were identified with a minimum 5-year follow-up. All THAs had a 32- or 36-mm metal (n = 30) or ceramic (n = 30) femoral head coupled with highly cross-linked polyethylene. Cobalt, chromium, and nickel ions were measured. Patients with metal heads had detectable cobalt and chromium levels. Cobalt levels were detectable in 17 (56.7%) patients with a mean of 2.0 μg/L (range: <1.0-10.8 μg/L). Chromium levels were detectable in 5 (16.7%) patients with a mean of 0.3 μg/L (range: <1.0-2.2 μg/L). All patients with a ceramic head had nondetectable cobalt and chromium levels. Cobalt and chromium levels were significantly higher with metal heads compared to ceramic heads (P < .01). Cobalt levels were significantly higher with 36-mm metal heads compared with 32-mm heads (P < .01). Seven patients with metal femoral heads had mild hip symptoms, 4 of whom had positive findings of early adverse local tissue reaction on magnetic resonance imaging. All ceramic THA was asymptomatic. The incidence and magnitude of cobalt and chromium levels is higher in metal heads compared to ceramic heads with this implant system (P < .01). Thirty-six millimeter metal femoral heads result in larger levels of cobalt compared with 32-mm metal heads. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Fehre, K.; Trojanowskaja, D.; Gatzke, J.; Kunitski, M.; Trinter, F.; Zeller, S.; Schmidt, L. Ph. H.; Stohner, J.; Berger, R.; Czasch, A.; Jagutzki, O.; Jahnke, T.; Dörner, R.; Schöffler, M. S.
2018-04-01
Modern momentum imaging techniques allow for the investigation of complex molecules in the gas phase by detection of several fragment ions in coincidence. For these studies, it is of great importance that the single-particle detection efficiency ɛ is as high as possible, as the overall efficiency scales with ɛn, i.e., the power of the number of detected particles. Here we present measured absolute detection efficiencies for protons of several micro-channel plates (MCPs), including efficiency enhanced "funnel MCPs." Furthermore, the relative detection efficiency for two-, three-, four-, and five-body fragmentation of CHBrClF has been examined. The "funnel" MCPs exhibit an efficiency of approximately 90%, gaining a factor of 24 (as compared to "normal" MCPs) in the case of a five-fold ion coincidence detection.
Noninvasive analysis of human neck muscle function
NASA Technical Reports Server (NTRS)
Conley, M. S.; Meyer, R. A.; Bloomberg, J. J.; Feeback, D. L.; Dudley, G. A.
1995-01-01
STUDY DESIGN. Muscle use evoked by exercise was determined by quantifying shifts in signal relaxation times of T2-weighted magnetic resonance images. Images were collected at rest and after exercise at each of two intensities (moderate and intense) for each of four head movements: 1) extension, 2) flexion, 3) rotation, and 4) lateral flexion. OBJECTIVE. This study examined the intensity and pattern of neck muscle use evoked by various movements of the head. The results will help elucidate the pathophysiology, and thus methods for treating disorders of the cervical musculoskeletal system. SUMMARY OF BACKGROUND DATA. Exercise-induced contrast shifts in T2 has been shown to indicate muscle use during the activity. The noninvasive nature of magnetic resonance imaging appears to make it an ideal approach for studying the function of the complex neuromuscular system of the neck. METHODS. The extent of T2 increase was examined to gauge how intensely nine different neck muscles or muscle pairs were used in seven subjects. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation was assessed to infer the pattern of use among and within individual neck muscles or muscle pairs. RESULTS. Signal relaxation increased with exercise intensity for each head movement. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation also increased with exercise load. Neck muscles or muscle pairs extensively used to perform each head movement were: extension--semispinalis capitis and cervicis and splenius capitis; flexion--sternocleidomastoid and longus capitis and colli; rotation--splenius capitis, levator scapulae, scalenus, semispinalis capitis ipsilateral to the rotation, and sternocleidomastoid contralateral; and lateral flexion--sternocleidomastoid CONCLUSION. The results of this study, in part, agree with the purported functions of neck muscles derived from anatomic location. This also was true for the few selected muscles that have been examined in human electromyographic studies. Neck muscle function and morphology can be studied at a detailed level using exercise-induced shifts in magnetic resonance images.
Ding, Yi; Peng, Kai; Yu, Miao; Lu, Lei; Zhao, Kun
2017-08-01
The performance of the two selected spatial frequency phase unwrapping methods is limited by a phase error bound beyond which errors will occur in the fringe order leading to a significant error in the recovered absolute phase map. In this paper, we propose a method to detect and correct the wrong fringe orders. Two constraints are introduced during the fringe order determination of two selected spatial frequency phase unwrapping methods. A strategy to detect and correct the wrong fringe orders is also described. Compared with the existing methods, we do not need to estimate the threshold associated with absolute phase values to determine the fringe order error, thus making it more reliable and avoiding the procedure of search in detecting and correcting successive fringe order errors. The effectiveness of the proposed method is validated by the experimental results.
The research on a novel type of the solar-blind UV head-mounted displays
NASA Astrophysics Data System (ADS)
Zhao, Shun-long
2011-08-01
Ultraviolet technology of detecting is playing a more and more important role in the field of civil application, especially in the corona discharge detection, in modern society. Now the UV imaging detector is one of the most important equipments in power equipment flaws detection. And the modern head-mounted displays (HMDs) have shown the applications in the fields of military, industry production, medical treatment, entertainment, 3D visualization, education and training. We applied the system of head-mounted displays to the UV image detection, and a novel type of head-mounted displays is presented: the solar-blind UV head-mounted displays. And the structure is given. By the solar-blind UV head-mounted displays, a real-time, isometric and visible image of the corona discharge is correctly displayed upon the background scene where it exists. The user will see the visible image of the corona discharge on the real scene rather than on a small screen. Then the user can easily find out the power equipment flaws and repair them. Compared with the traditional UV imaging detector, the introducing of the HMDs simplifies the structure of the whole system. The original visible spectrum optical system is replaced by the eye in the solar-blind UV head-mounted displays. And the optical image fusion technology would be used rather than the digital image fusion system which is necessary in traditional UV imaging detector. That means the visible spectrum optical system and digital image fusion system are not necessary. This makes the whole system cheaper than the traditional UV imaging detector. Another advantage of the solar-blind UV head-mounted displays is that the two hands of user will be free. So while observing the corona discharge the user can do some things about it. Therefore the solar-blind UV head-mounted displays can make the corona discharge expose itself to the user in a better way, and it will play an important role in corona detection in the future.
Bouvresse, Sophie; Socolovshi, Cristina; Berdjane, Zohra; Durand, Rémy; Izri, Arezki; Raoult, Didier; Chosidow, Olivier; Brouqui, Philippe
2011-12-01
The human body louse is the only known vector of Bartonella quintana. However, the presence of this bacterium has recently been detected in the head lice of homeless individuals and Nepalese slum children. Previous studies have reported the isolation of Acinetobacter baumannii from the body lice of homeless individuals. An epidemiological survey including 74 schools was conducted between 2008 and 2009 in Paris. After a first visual examination, the hair of children with suspected pediculosis was combed with a fine-tooth comb to collect live adult head lice. Molecular studies were performed on randomly selected DNA samples to detect B. quintana and A. baumannii by specific quantitative real-time PCR. Among a collection of 288 DNA samples, B. quintana was not detected, but A. baumannii was detected in 95 DNA samples (33%). Further study is needed to determine the significance of the finding of A. baumannii in head lice. 2011. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yamada, Masayoshi; Fukuzawa, Masayuki; Kitsunezuka, Yoshiki; Kishida, Jun; Nakamori, Nobuyuki; Kanamori, Hitoshi; Sakurai, Takashi; Kodama, Souichi
1995-05-01
In order to detect pulsation from a series of noisy ultrasound-echo moving images of a newborn baby's head for pediatric diagnosis, a digital image processing system capable of recording at the video rate and processing the recorded series of images was constructed. The time-sequence variations of each pixel value in a series of moving images were analyzed and then an algorithm based on Fourier transform was developed for the pulsation detection, noting that the pulsation associated with blood flow was periodically changed by heartbeat. Pulsation detection for pediatric diagnosis was successfully made from a series of noisy ultrasound-echo moving images of newborn baby's head by using the image processing system and the pulsation detection algorithm developed here.
Photorefractor ocular screening system
NASA Technical Reports Server (NTRS)
Richardson, John R. (Inventor); Kerr, Joseph H. (Inventor)
1987-01-01
A method and apparatus for detecting human eye defects, particularly detection of refractive error is presented. Eye reflex is recorded on color film when the eyes are exposed to a flash of light. The photographs are compared with predetermined standards to detect eye defects. The base structure of the ocular screening system is a folding interconnect structure, comprising hinged sections. Attached to one end of the structure is a head positioning station which comprises vertical support, a head positioning bracket having one end attached to the top of the support, and two head positioning lamps to verify precise head positioning. At the opposite end of the interconnect structure is a camera station with camera, electronic flash unit, and blinking fixation lamp, for photographing the eyes of persons being evaluated.
From tiger to panda: animal head detection.
Zhang, Weiwei; Sun, Jian; Tang, Xiaoou
2011-06-01
Robust object detection has many important applications in real-world online photo processing. For example, both Google image search and MSN live image search have integrated human face detector to retrieve face or portrait photos. Inspired by the success of such face filtering approach, in this paper, we focus on another popular online photo category--animal, which is one of the top five categories in the MSN live image search query log. As a first attempt, we focus on the problem of animal head detection of a set of relatively large land animals that are popular on the internet, such as cat, tiger, panda, fox, and cheetah. First, we proposed a new set of gradient oriented feature, Haar of Oriented Gradients (HOOG), to effectively capture the shape and texture features on animal head. Then, we proposed two detection algorithms, namely Bruteforce detection and Deformable detection, to effectively exploit the shape feature and texture feature simultaneously. Experimental results on 14,379 well labeled animals images validate the superiority of the proposed approach. Additionally, we apply the animal head detector to improve the image search result through text based online photo search result filtering.
Detection of bacterial pathogens including potential new species in human head lice from Mali
Amanzougaghene, Nadia; Fenollar, Florence; Sangaré, Abdoul Karim; Sissoko, Mahamadou S.; Doumbo, Ogobara K.; Raoult, Didier
2017-01-01
In poor African countries, where no medical and biological facilities are available, the identification of potential emerging pathogens of concern at an early stage is challenging. Head lice, Pediculus humanus capitis, have a short life, feed only on human blood and do not transmit pathogens to their progeny. They are, therefore, a perfect tool for the xenodiagnosis of current or recent human infection. This study assessed the occurrence of bacterial pathogens from head lice collected in two rural villages from Mali, where a high frequency of head lice infestation had previously been reported, using molecular methods. Results show that all 600 head lice, collected from 117 individuals, belonged to clade E, specific to West Africa. Bartonella quintana, the causative agent of trench fever, was identified in three of the 600 (0.5%) head lice studied. Our study also shows, for the first time, the presence of the DNA of two pathogenic bacteria, namely Coxiella burnetii (5.1%) and Rickettsia aeschlimannii (0.6%), detected in human head lice, as well as the DNA of potential new species from the Anaplasma and Ehrlichia genera of unknown pathogenicity. The finding of several Malian head lice infected with B. quintana, C. burnetii, R. aeschlimannii, Anaplasma and Ehrlichia is alarming and highlights the need for active survey programs to define the public health consequences of the detection of these emerging bacterial pathogens in human head lice. PMID:28931077
Detection of bacterial pathogens including potential new species in human head lice from Mali.
Amanzougaghene, Nadia; Fenollar, Florence; Sangaré, Abdoul Karim; Sissoko, Mahamadou S; Doumbo, Ogobara K; Raoult, Didier; Mediannikov, Oleg
2017-01-01
In poor African countries, where no medical and biological facilities are available, the identification of potential emerging pathogens of concern at an early stage is challenging. Head lice, Pediculus humanus capitis, have a short life, feed only on human blood and do not transmit pathogens to their progeny. They are, therefore, a perfect tool for the xenodiagnosis of current or recent human infection. This study assessed the occurrence of bacterial pathogens from head lice collected in two rural villages from Mali, where a high frequency of head lice infestation had previously been reported, using molecular methods. Results show that all 600 head lice, collected from 117 individuals, belonged to clade E, specific to West Africa. Bartonella quintana, the causative agent of trench fever, was identified in three of the 600 (0.5%) head lice studied. Our study also shows, for the first time, the presence of the DNA of two pathogenic bacteria, namely Coxiella burnetii (5.1%) and Rickettsia aeschlimannii (0.6%), detected in human head lice, as well as the DNA of potential new species from the Anaplasma and Ehrlichia genera of unknown pathogenicity. The finding of several Malian head lice infected with B. quintana, C. burnetii, R. aeschlimannii, Anaplasma and Ehrlichia is alarming and highlights the need for active survey programs to define the public health consequences of the detection of these emerging bacterial pathogens in human head lice.
Stackman, Robert W.; Lora, Joan C.; Williams, Sidney B.
2012-01-01
Recent findings indicate that rats navigate in spatial tasks such as the Morris water maze (MWM) using a local cue-based reference frame rather than a distal cue-based reference frame. Specifically, rats swim in a particular direction to a location relative to pool-based cues, rather than to an absolute location defined by room-based cues. Neural mechanisms supporting this bias in rodents for relative responding in spatial tasks are not yet understood. Anterior thalamic neurons discharge according to the current directional heading of the animal. The contribution of head direction (HD) cell activity to navigation has been difficult to elucidate. We found that male C57BL/6J mice trained for 4 or 7 days in the MWM exhibited an overwhelming preference for swimming in a direction relative to pool-based cues over absolute responding during a platform-less probe test. Rotation of extra-maze cues caused a corresponding rotation of the direction mice swam during probe test, suggesting that both pool- and room-based reference frames guide platform search. However, disorienting the mice before the probe test disturbed relative responding. Therefore, relative responding is guided by both internal and external cue sources. Selective inactivation of anterior thalamic nuclei (ATN) by microinfusion of muscimol or fluorophore-conjugated muscimol caused a near complete shift in preference from relative to absolute responding. Interestingly, inactivation of the dorsal CA1 region of the hippocampus did not affect relative responding. These data suggest that ATN, and HD cells therein, may guide relative responding in the MWM, a task considered by most to reflect hippocampal processing. PMID:22836256
Liang, Yun; Kim, Gwe-Ya; Pawlicki, Todd; Mundt, Arno J; Mell, Loren K
2013-03-04
The purpose of this study was to develop dosimetry verification procedures for volumetric-modulated arc therapy (VMAT)-based total marrow irradiation (TMI). The VMAT based TMI plans were generated for three patients: one child and two adults. The planning target volume (PTV) was defined as bony skeleton, from head to mid-femur, with a 3 mm margin. The plan strategy similar to published studies was adopted. The PTV was divided into head and neck, chest, and pelvic regions, with separate plans each of which is composed of 2-3 arcs/fields. Multiple isocenters were evenly distributed along the patient's axial direction. The focus of this study is to establish a dosimetry quality assurance procedure involving both two-dimensional (2D) and three-dimensional (3D) volumetric verifications, which is desirable for a large PTV treated with multiple isocenters. The 2D dose verification was performed with film for gamma evaluation and absolute point dose was measured with ion chamber, with attention to the junction between neighboring plans regarding hot/cold spots. The 3D volumetric dose verification used commercial dose reconstruction software to reconstruct dose from electronic portal imaging devices (EPID) images. The gamma evaluation criteria in both 2D and 3D verification were 5% absolute point dose difference and 3 mm of distance to agreement. With film dosimetry, the overall average gamma passing rate was 98.2% and absolute dose difference was 3.9% in junction areas among the test patients; with volumetric portal dosimetry, the corresponding numbers were 90.7% and 2.4%. A dosimetry verification procedure involving both 2D and 3D was developed for VMAT-based TMI. The initial results are encouraging and warrant further investigation in clinical trials.
Vision-Aided Context-Aware Framework for Personal Navigation Services
NASA Astrophysics Data System (ADS)
Saeedi, S.; Moussa, A.; El-Sheimy, N., , Dr.
2012-07-01
The ubiquity of mobile devices (such as smartphones and tablet-PCs) has encouraged the use of location-based services (LBS) that are relevant to the current location and context of a mobile user. The main challenge of LBS is to find a pervasive and accurate personal navigation system (PNS) in different situations of a mobile user. In this paper, we propose a method of personal navigation for pedestrians that allows a user to freely move in outdoor environments. This system aims at detection of the context information which is useful for improving personal navigation. The context information for a PNS consists of user activity modes (e.g. walking, stationary, driving, and etc.) and the mobile device orientation and placement with respect to the user. After detecting the context information, a low-cost integrated positioning algorithm has been employed to estimate pedestrian navigation parameters. The method is based on the integration of the relative user's motion (changes of velocity and heading angle) estimation based on the video image matching and absolute position information provided by GPS. A Kalman filter (KF) has been used to improve the navigation solution when the user is walking and the phone is in his/her hand. The Experimental results demonstrate the capabilities of this method for outdoor personal navigation systems.
Localised photoplethysmography imaging for heart rate estimation of pre-term infants in the clinic
NASA Astrophysics Data System (ADS)
Chaichulee, Sitthichok; Villarroel, Mauricio; Jorge, João.; Arteta, Carlos; Green, Gabrielle; McCormick, Kenny; Zisserman, Andrew; Tarassenko, Lionel
2018-02-01
Non-contact vital-sign estimation allows the monitoring of physiological parameters (such as heart rate, respiratory rate, and peripheral oxygen saturation) without contact electrodes or sensors. Our recent work has demonstrated that a convolutional neural network (CNN) can be used to detect the presence of a patient and segment the patient's skin area for vital-sign estimation, thus enabling the automatic continuous monitoring of vital signs in a hospital environment. In a study approved by the local Research Ethical Committee, we made video recordings of pre-term infants nursed in a Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford, UK. We extended the CNN model to detect the head, torso and diaper of the infants. We extracted multiple photoplethysmographic imaging (PPGi) signals from each body part, analysed their signal quality, and compared them with the PPGi signal derived from the entire skin area. Our results demonstrated the benefits of estimating heart rate combined from multiple regions of interest using data fusion. In the test dataset, we achieved a mean absolute error of 2.4 beats per minute for 80% (31.1 hours) from a total recording time of 38.5 hours for which both reference heart rate and video data were valid.
Chiarelli, Antonio M.; Maclin, Edward L.; Low, Kathy A.; Fantini, Sergio; Fabiani, Monica; Gratton, Gabriele
2017-01-01
Abstract. Near infrared (NIR) light has been widely used for measuring changes in hemoglobin concentration in the human brain (functional NIR spectroscopy, fNIRS). fNIRS is based on the differential measurement and estimation of absorption perturbations, which, in turn, are based on correctly estimating the absolute parameters of light propagation. To do so, it is essential to accurately characterize the baseline optical properties of tissue (absorption and reduced scattering coefficients). However, because of the diffusive properties of the medium, separate determination of absorption and scattering across the head is challenging. The effective attenuation coefficient (EAC), which is proportional to the geometric mean of absorption and reduced scattering coefficients, can be estimated in a simpler fashion by multidistance light decay measurements. EAC mapping could be of interest for the scientific community because of its absolute information content, and because light propagation is governed by the EAC for source–detector distances exceeding 1 cm, which sense depths extending beyond the scalp and skull layers. Here, we report an EAC mapping procedure that can be applied to standard fNIRS recordings, yielding topographic maps with 2- to 3-cm resolution. Application to human data indicates the importance of venous sinuses in determining regional EAC variations, a factor often overlooked. PMID:28466026
Cervical joint position sense in rugby players versus non-rugby players.
Pinsault, Nicolas; Anxionnaz, Marion; Vuillerme, Nicolas
2010-05-01
To determine whether cervical joint position sense is modified by intensive rugby practice. A group-comparison study. University Medical Bioengineering Laboratory. Twenty young elite rugby players (10 forwards and 10 backs) and 10 young non-rugby elite sports players. Participants were asked to perform the cervicocephalic relocation test (CRT) to the neutral head position (NHP) that is, to reposition their head on their trunk, as accurately as possible, after full active left and right cervical rotation. Rugby players were asked to perform the CRT to NHP before and after a training session. Absolute and variable errors were used to assess accuracy and consistency of the repositioning for the three groups of Forwards, Backs and Non-rugby players, respectively. The 2 groups of Forwards and Backs exhibited higher absolute and variable errors than the group of Non-rugby players. No difference was found between the two groups of Forwards and Backs and no difference was found between Before and After the training session. The cervical joint position sense of young elite rugby players is altered compared to that of non-rugby players. Furthermore, Forwards and Backs demonstrated comparable repositioning errors before and after a specific training session, suggesting that cervical proprioceptive alteration is mainly due to tackling and not the scrum.
Chiarelli, Antonio M; Maclin, Edward L; Low, Kathy A; Fantini, Sergio; Fabiani, Monica; Gratton, Gabriele
2017-04-01
Near infrared (NIR) light has been widely used for measuring changes in hemoglobin concentration in the human brain (functional NIR spectroscopy, fNIRS). fNIRS is based on the differential measurement and estimation of absorption perturbations, which, in turn, are based on correctly estimating the absolute parameters of light propagation. To do so, it is essential to accurately characterize the baseline optical properties of tissue (absorption and reduced scattering coefficients). However, because of the diffusive properties of the medium, separate determination of absorption and scattering across the head is challenging. The effective attenuation coefficient (EAC), which is proportional to the geometric mean of absorption and reduced scattering coefficients, can be estimated in a simpler fashion by multidistance light decay measurements. EAC mapping could be of interest for the scientific community because of its absolute information content, and because light propagation is governed by the EAC for source-detector distances exceeding 1 cm, which sense depths extending beyond the scalp and skull layers. Here, we report an EAC mapping procedure that can be applied to standard fNIRS recordings, yielding topographic maps with 2- to 3-cm resolution. Application to human data indicates the importance of venous sinuses in determining regional EAC variations, a factor often overlooked.
NASA Astrophysics Data System (ADS)
Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald
2015-08-01
We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.
van Battum, L J; Hoffmans, D; Piersma, H; Heukelom, S
2008-02-01
This paper focuses on the accuracy, in absolute dose measurements, with GafChromicTM EBT film achievable in water for a 6 MV photon beam up to a dose of 2.3 Gy. Motivation is to get an absolute dose detection system to measure up dose distributions in a (water) phantom, to check dose calculations. An Epson 1680 color (red green blue) transmission flatbed scanner has been used as film scanning system, where the response in the red color channel has been extracted and used for the analyses. The influence of the flatbed film scanner on the film based dose detection process was investigated. The scan procedure has been optimized; i.e. for instance a lateral correction curve was derived to correct the scan value, up to 10%, as a function of optical density and lateral position. Sensitometric curves of different film batches were evaluated in portrait and landscape scan mode. Between various batches important variations in sensitometric curve were observed. Energy dependence of the film is negligible, while a slight variation in dose response is observed for very large angles between film surface and incident photon beam. Improved accuracy in absolute dose detection can be obtained by repetition of a film measurement to tackle at least the inherent presence of film inhomogeneous construction. We state that the overall uncertainty is random in absolute EBT film dose detection and of the order of 1.3% (1 SD) under the condition that the film is scanned in a limited centered area on the scanner and at least two films have been applied. At last we advise to check a new film batch on its characteristics compared to available information, before using that batch for absolute dose measurements.
Muñoz, Marcelo A; González, Natalia; Joseph-Nathan, Pedro
2016-07-01
The absolute configuration of the naturally occurring isomers of 6β-benzoyloxy-3α-tropanol (1) has been established by the combined use of chiral high-performance liquid chromatography with electronic circular dichroism detection and optical rotation detection. For this purpose (±)-1, prepared in two steps from racemic 6-hydroxytropinone (4), was subjected to chiral high-performance liquid chromatography with electronic circular dichroism and optical rotation detection allowing the online measurement of both chiroptical properties for each enantiomer, which in turn were compared with the corresponding values obtained from density functional theory calculations. In an independent approach, preparative high-performance liquid chromatography separation using an automatic fraction collector, yielded an enantiopure sample of OR (+)-1 whose vibrational circular dichroism spectrum allowed its absolute configuration assignment when the bands in the 1100-950 cm(-1) region were compared with those of the enantiomers of esters derived from 3α,6β-tropanediol. In addition, an enantiomerically enriched sample of 4, instead of OR (±)-4, was used for the same transformation sequence, whose high-performance liquid chromatography follow-up allowed their spectroscopic correlation. All evidences lead to the OR (+)-(1S,3R,5S,6R) and OR (-)-(1R,3S,5R,6S) absolute configurations, from where it follows that samples of 1 isolated from Knightia strobilina and Erythroxylum zambesiacum have the OR (+)-(1S,3R,5S,6R) absolute configuration, while the sample obtained from E. rotundifolium has the OR (-)-(1R,3S,5R,6S) absolute configuration. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Early diagnosis of severe combined immunodeficiency (SCID) in Turkey: a pilot study.
Can, Ceren; Hamilçıkan, Şahin; Can, Emrah
2017-08-29
Severe combined immunodeficiency (SCID) is a neonatal emergency. As the T-cell receptor excision circles (TREC) test is not cost effective for neonatal screening of SCID in developing countries, this pilot study's objective aimed at identifying preliminary data to enable SCID identification in the general population. This observational study was performed in Bagcılar Training and Research Hospital, Istanbul, Turkey. Cord-blood complete blood count (CBC) was recorded in all neonates included in the study. Absolute lymphopenia was considered in cord-blood samples if the absolute lymphocyte count was less than 2500/mm 3 . A control blood count was performed 1-month later for cases with detected lymphopenia. A total of 2945 term neonates were included in the study. Absolute lymphopenia was found in nine (0.3%) neonates, while 2936 (99.7%) had an absolute lymphocytic count above 2.5 × 10 3 /mm 3 . The mean counts of red blood cells (RBC), hemoglobin (HGB), hematocrit (HCT), platelets (PLT), and monocytes in the lymphopenia group were not found to significantly differ from the non-lymphopenia group. However, there were significantly lower mean white blood cell (WBC), lymphocyte, and neutrophil counts between the groups (p < .05). Absolute lymphopenia detected using CBC analysis is a simple, easier, more non-invasive, and cheaper method than the TREC method for detection of SCID neonates, and this method may prove to be a useful alternative, especially in developing countries.
Head Pose Estimation on Eyeglasses Using Line Detection and Classification Approach
NASA Astrophysics Data System (ADS)
Setthawong, Pisal; Vannija, Vajirasak
This paper proposes a unique approach for head pose estimation of subjects with eyeglasses by using a combination of line detection and classification approaches. Head pose estimation is considered as an important non-verbal form of communication and could also be used in the area of Human-Computer Interface. A major improvement of the proposed approach is that it allows estimation of head poses at a high yaw/pitch angle when compared with existing geometric approaches, does not require expensive data preparation and training, and is generally fast when compared with other approaches.
A Reward-Based Behavioral Platform to Measure Neural Activity during Head-Fixed Behavior
Micallef, Andrew H.; Takahashi, Naoya; Larkum, Matthew E.; Palmer, Lucy M.
2017-01-01
Understanding the neural computations that contribute to behavior requires recording from neurons while an animal is behaving. This is not an easy task as most subcellular recording techniques require absolute head stability. The Go/No-Go sensory task is a powerful decision-driven task that enables an animal to report a binary decision during head-fixation. Here we discuss how to set up an Ardunio and Python based platform system to control a Go/No-Go sensory behavior paradigm. Using an Arduino micro-controller and Python-based custom written program, a reward can be delivered to the animal depending on the decision reported. We discuss the various components required to build the behavioral apparatus that can control and report such a sensory stimulus paradigm. This system enables the end user to control the behavioral testing in real-time and therefore it provides a strong custom-made platform for probing the neural basis of behavior. PMID:28620282
Strojan, Primož; Vermorken, Jan B; Beitler, Jonathan J; Saba, Nabil F; Haigentz, Missak; Bossi, Paolo; Worden, Francis P; Langendijk, Johannes A; Eisbruch, Avraham; Mendenhall, William M; Lee, Anne W M; Harrison, Louis B; Bradford, Carol R; Smee, Robert; Silver, Carl E; Rinaldo, Alessandra; Ferlito, Alfio
2016-04-01
The optimal cumulative dose and timing of cisplatin administration in various concurrent chemoradiotherapy protocols for nonmetastatic head and neck squamous cell carcinoma (HNSCC) has not been determined. The absolute survival benefit at 5 years of concurrent chemoradiotherapy protocols versus radiotherapy alone observed in prospective randomized trials reporting on the use of cisplatin monochemotherapy for nonnasopharyngeal HNSCC was extracted. In the case of nonrandomized studies, the outcome results at 2 years were compared between groups of patients receiving different cumulative cisplatin doses. Eleven randomized trials and 7 nonrandomized studies were identified. In 6 definitive radiotherapy phase III trials, a statistically significant association (p = .027) between cumulative cisplatin dose, independent of the schedule, and overall survival benefit was observed for higher doses. Results support the conclusion that the cumulative dose of cisplatin in concurrent chemoradiation protocols for HNSCC has a significant positive correlation with survival. © 2015 Wiley Periodicals, Inc. Head Neck 38: E2151-E2158, 2016. © 2015 Wiley Periodicals, Inc.
Correcting electrode modelling errors in EIT on realistic 3D head models.
Jehl, Markus; Avery, James; Malone, Emma; Holder, David; Betcke, Timo
2015-12-01
Electrical impedance tomography (EIT) is a promising medical imaging technique which could aid differentiation of haemorrhagic from ischaemic stroke in an ambulance. One challenge in EIT is the ill-posed nature of the image reconstruction, i.e., that small measurement or modelling errors can result in large image artefacts. It is therefore important that reconstruction algorithms are improved with regard to stability to modelling errors. We identify that wrongly modelled electrode positions constitute one of the biggest sources of image artefacts in head EIT. Therefore, the use of the Fréchet derivative on the electrode boundaries in a realistic three-dimensional head model is investigated, in order to reconstruct electrode movements simultaneously to conductivity changes. We show a fast implementation and analyse the performance of electrode position reconstructions in time-difference and absolute imaging for simulated and experimental voltages. Reconstructing the electrode positions and conductivities simultaneously increased the image quality significantly in the presence of electrode movement.
Continuous-wave EPR at 275 GHz: Application to high-spin Fe 3+ systems
NASA Astrophysics Data System (ADS)
Mathies, G.; Blok, H.; Disselhorst, J. A. J. M.; Gast, P.; van der Meer, H.; Miedema, D. M.; Almeida, R. M.; Moura, J. J. G.; Hagen, W. R.; Groenen, E. J. J.
2011-05-01
The 275 GHz electron-paramagnetic-resonance spectrometer we reported on in 2004 has been equipped with a new probe head, which contains a cavity especially designed for operation in continuous-wave mode. The sensitivity and signal stability that is achieved with this new probe head is illustrated with 275 GHz continuous-wave spectra of a 1 mM frozen solution of the complex Fe(III)-ethylenediamine tetra-acetic acid and of 10 mM frozen solutions of the protein rubredoxin, which contains Fe 3+ in its active site, from three different organisms. The high quality of the spectra of the rubredoxins allows the determination of the zero-field-splitting parameters with an accuracy of 0.5 GHz. The success of our approach results partially from the enhanced absolute sensitivity, which can be reached using a single-mode cavity. At least as important is the signal stability that we were able to achieve with the new probe head.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pal, Sambit Bikas; Haldar, Arijit; Roy, Basudev
A photonic force microscope comprises of an optically trapped micro-probe and a position detection system to track the motion of the probe. Signal collection for motion detection is often carried out using the backscattered light off the probe-however, this mode has problems of low S/N due to the small backscattering cross sections of the micro-probes typically used. The position sensors often used in these cases are quadrant photodetectors. To ensure maximum sensitivity of such detectors, it would help if the detector size matched with the detection beam radius after the condenser lens (which for backscattered detection would be the trappingmore » objective itself). To suit this condition, we have used a miniature displacement sensor whose dimensions makes it ideal to work with 1:1 images of micrometer-sized trapped probes in the backscattering detection mode. The detector is based on the quadrant photo-integrated chip in the optical pick-up head of a compact disc player. Using this detector, we measured absolute displacements of an optically trapped 1.1 {mu}m probe with a resolution of {approx}10 nm for a bandwidth of 10 Hz at 95% significance without any sample or laser stabilization. We characterized our optical trap for different sized probes by measuring the power spectrum for each probe to 1% accuracy, and found that for 1.1 {mu}m diameter probes, the noise in our position measurement matched the thermal resolution limit for averaging times up to 10 ms. We also achieved a linear response range of around 385 nm with cross talk between axes {approx_equal}4% for 1.1 {mu}m diameter probes. The detector has extremely high bandwidth (few MHz) and low optical power threshold-other factors that can lead to its widespread use in photonic force microscopy.« less
CT scan range estimation using multiple body parts detection: let PACS learn the CT image content.
Wang, Chunliang; Lundström, Claes
2016-02-01
The aim of this study was to develop an efficient CT scan range estimation method that is based on the analysis of image data itself instead of metadata analysis. This makes it possible to quantitatively compare the scan range of two studies. In our study, 3D stacks are first projected to 2D coronal images via a ray casting-like process. Trained 2D body part classifiers are then used to recognize different body parts in the projected image. The detected candidate regions go into a structure grouping process to eliminate false-positive detections. Finally, the scale and position of the patient relative to the projected figure are estimated based on the detected body parts via a structural voting. The start and end lines of the CT scan are projected to a standard human figure. The position readout is normalized so that the bottom of the feet represents 0.0, and the top of the head is 1.0. Classifiers for 18 body parts were trained using 184 CT scans. The final application was tested on 136 randomly selected heterogeneous CT scans. Ground truth was generated by asking two human observers to mark the start and end positions of each scan on the standard human figure. When compared with the human observers, the mean absolute error of the proposed method is 1.2% (max: 3.5%) and 1.6% (max: 5.4%) for the start and end positions, respectively. We proposed a scan range estimation method using multiple body parts detection and relative structure position analysis. In our preliminary tests, the proposed method delivered promising results.
SU-F-T-472: Validation of Absolute Dose Measurements for MR-IGRT With and Without Magnetic Field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Green, O; Li, H; Goddu, S
Purpose: To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. Methods: The standard method (AAPM’s TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 cc) and the PTW (Freiburg, Germany). A previously reported Monte Carlo simulation suggested a difference on the order of 0.5% for dose measured with and without the presence of the magnetic field, but testing this was not possible until anmore » engineering solution to allow the radiation system to be used without the nominal magnetic field was found. A previously identified effect of orientation in the magnetic field was also tested by placing the chamber either parallel or perpendicular to the field and irradiating from two opposing angles (90 and 270). Finally, the Imaging and Radiation Oncology Core provided OSLD detectors for five irradiations each with and without the field - with two heads at both 0 and 90 degrees, and one head at 90 degrees only as it doesn’t reach 0 (IEC convention). Results: For the TG-51 comparison, expected dose was obtained by decaying values measured at the time of source installation. The average measured difference was 0.4%±0.12% for A18 and 0.06%±0.15% for Farmer chamber. There was minimal (0.3%) orientation dependence without the magnetic field for the A18 chamber, while previous measurements with the magnetic field had a deviation of 3.2% with chamber perpendicular to magnetic field. Results reported by IROC for the OSLDs with and without the field had a maximum difference of 2%. Conclusion: Accurate absolute dosimetry was verified by measurement under the same conditions with and without the magnetic field for both ionization chambers and independently-verifiable OSLDs.« less
Multiview face detection based on position estimation over multicamera surveillance system
NASA Astrophysics Data System (ADS)
Huang, Ching-chun; Chou, Jay; Shiu, Jia-Hou; Wang, Sheng-Jyh
2012-02-01
In this paper, we propose a multi-view face detection system that locates head positions and indicates the direction of each face in 3-D space over a multi-camera surveillance system. To locate 3-D head positions, conventional methods relied on face detection in 2-D images and projected the face regions back to 3-D space for correspondence. However, the inevitable false face detection and rejection usually degrades the system performance. Instead, our system searches for the heads and face directions over the 3-D space using a sliding cube. Each searched 3-D cube is projected onto the 2-D camera views to determine the existence and direction of human faces. Moreover, a pre-process to estimate the locations of candidate targets is illustrated to speed-up the searching process over the 3-D space. In summary, our proposed method can efficiently fuse multi-camera information and suppress the ambiguity caused by detection errors. Our evaluation shows that the proposed approach can efficiently indicate the head position and face direction on real video sequences even under serious occlusion.
Eye Tracking and Head Movement Detection: A State-of-Art Survey
2013-01-01
Eye-gaze detection and tracking have been an active research field in the past years as it adds convenience to a variety of applications. It is considered a significant untraditional method of human computer interaction. Head movement detection has also received researchers' attention and interest as it has been found to be a simple and effective interaction method. Both technologies are considered the easiest alternative interface methods. They serve a wide range of severely disabled people who are left with minimal motor abilities. For both eye tracking and head movement detection, several different approaches have been proposed and used to implement different algorithms for these technologies. Despite the amount of research done on both technologies, researchers are still trying to find robust methods to use effectively in various applications. This paper presents a state-of-art survey for eye tracking and head movement detection methods proposed in the literature. Examples of different fields of applications for both technologies, such as human-computer interaction, driving assistance systems, and assistive technologies are also investigated. PMID:27170851
Cano, I; Alonso, M C; Garcia-Rosado, E; Saint-Jean, S Rodriguez; Castro, D; Borrego, Juan J
2006-03-10
An immunoblot technique for the detection of lymphocystis disease virus (LCDV) in naturally infected gilt-head seabream (Sparus aurata, L.) has been developed. A specific antiserum against a 60 kDa viral protein has been proven to be an appropriate tool for LCDV diagnosis either from inoculated cell cultures or from fish tissues using the immunoblot assay. The sensitivity of this technique varied between 10(-1) and 10(2) TCID50. LCDV has also been detected in fish tissues from both, diseased and asymptomatic gilt-head seabream. For the asymptomatic fish detection, a viral amplification step in cell culture and a subsequent viral concentration using polyethylene glycol (PEG) (600 wt) are required. On the contrary, immunoblot allowed the detection of LCDV antigens directly from tissue homogenates of diseased fish. The method described in this study shows higher sensitivity than classical detection techniques based on cell culture inoculation.
Integrating an MR head into a peak detection channel
NASA Astrophysics Data System (ADS)
Curland, Nathan; Machelski, Russell J.
1994-03-01
Integrating a magnetoresistive (MR) head into a peak detection channel requires the engineer to deal with basic differences between MR and thin film heads. These differences result from nonlinear sensor response, separate write and read elements, and having an active element at the air bearing surface (ABS). A simple model for flux superposition can adequately address nonlinear effects and be used for equalization design. Timing budgets can be developed which demonstrate the dominance of media noise for present day systems. Single threshold qualification can handle most current system requirements. Separate read/write elements mean that more attention needs to be paid to offtrack equalization design and head dimensional tolerancing. An active element at the ABS requires better control of the head-disc potential and leakage currents.
Eremeeva, Marina E; Capps, Danielle; Winful, Emmanuel B; Warang, Shamta S; Braswell, Sarah E; Tokarevich, Nikolay K; Bonilla, Denise L; Durden, Lance A
2017-07-01
Although the head louse, Pediculus humanus capitis De Geer, and body louse, Pediculus humanus humanus L., both have a worldwide distribution, the occurrence of head louse pediculosis appears to be more prevalent in modern societies despite systematic use of various pediculicides. This study tested head lice collected in rural Georgia and body lice collected in Russia for the prevalence of a kdr-biomarker that is associated with permethrin resistance. This study also screened lice for the presence of DNA from Bartonella quintana and Acinetobacter species. The kdr-permethrin resistance biomarker for the T917I mutation was detected by RFLP and PCR in 99.9% of head lice tested from Georgia, whereas only 2.9% of body lice from Russia tested positive for this kdr biomarker. DNA of B. quintana was detected in 10.3% of head lice from Georgia, whereas 84.8% of body lice from Russia tested positive. Acinetobacter DNA was detected in 80.8% (95% CI, 68-89%) of head lice from Georgia and all body lice from Russia tested. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification.
Guan, Weihua; Chen, Liben; Rane, Tushar D; Wang, Tza-Huei
2015-09-03
We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples.
Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification
Guan, Weihua; Chen, Liben; Rane, Tushar D.; Wang, Tza-Huei
2015-01-01
We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples. PMID:26333806
Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification
NASA Astrophysics Data System (ADS)
Guan, Weihua; Chen, Liben; Rane, Tushar D.; Wang, Tza-Huei
2015-09-01
We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples.
Research on driver fatigue detection
NASA Astrophysics Data System (ADS)
Zhang, Ting; Chen, Zhong; Ouyang, Chao
2018-03-01
Driver fatigue is one of the main causes of frequent traffic accidents. In this case, driver fatigue detection system has very important significance in avoiding traffic accidents. This paper presents a real-time method based on fusion of multiple facial features, including eye closure, yawn and head movement. The eye state is classified as being open or closed by a linear SVM classifier trained using HOG features of the detected eye. The mouth state is determined according to the width-height ratio of the mouth. The head movement is detected by head pitch angle calculated by facial landmark. The driver's fatigue state can be reasoned by the model trained by above features. According to experimental results, drive fatigue detection obtains an excellent performance. It indicates that the developed method is valuable for the application of avoiding traffic accidents caused by driver's fatigue.
An evaluation of 3D head pose estimation using the Microsoft Kinect v2.
Darby, John; Sánchez, María B; Butler, Penelope B; Loram, Ian D
2016-07-01
The Kinect v2 sensor supports real-time non-invasive 3D head pose estimation. Because the sensor is small, widely available and relatively cheap it has great potential as a tool for groups interested in measuring head posture. In this paper we compare the Kinect's head pose estimates with a marker-based record of ground truth in order to establish its accuracy. During movement of the head and neck alone (with static torso), we find average errors in absolute yaw, pitch and roll angles of 2.0±1.2°, 7.3±3.2° and 2.6±0.7°, and in rotations relative to the rest pose of 1.4±0.5°, 2.1±0.4° and 2.0±0.8°. Larger head rotations where it becomes difficult to see facial features can cause estimation to fail (10.2±6.1% of all poses in our static torso range of motion tests) but we found no significant changes in performance with the participant standing further away from Kinect - additionally enabling full-body pose estimation - or without performing face shape calibration, something which is not always possible for younger or disabled participants. Where facial features remain visible, the sensor has applications in the non-invasive assessment of postural control, e.g. during a programme of physical therapy. In particular, a multi-Kinect setup covering the full range of head (and body) movement would appear to be a promising way forward. Copyright © 2016 Elsevier B.V. All rights reserved.
Feasibility of measuring dissolved carbon dioxide based on head space partial pressures
Watten, B.J.; Boyd, C.E.; Schwartz, M.F.; Summerfelt, S.T.; Brazil, B.L.
2004-01-01
We describe an instrument prototype that measures dissolved carbon dioxide (DC) without need for standard wetted probe membranes or titration. DC is calculated using Henry's Law, water temperature, and the steady-state partial pressure of carbon dioxide that develops within the instrument's vertical gas-liquid contacting chamber. Gas-phase partial pressures were determined with either an infrared detector (ID) or by measuring voltage developed by a pH electrode immersed in an isolated sodium carbonate solution (SC) sparged with recirculated head space gas. Calculated DC concentrations were compared with those obtained by titration over a range of DC (2, 4, 8, 12, 16, 20, 24, and 28mg/l), total alkalinity (35, 120, and 250mg/l as CaCO3), total dissolved gas pressure (-178 to 120 mmHg), and dissolved oxygen concentrations (7, 14, and 18 mg/l). Statistically significant (P < 0.001) correlations were established between head space (ID) and titrimetrically determined DC concentrations (R2 = 0.987-0.999, N = 96). Millivolt and titrimetric values from the SC solution tests were also correlated (P < 0.001, R 2 = 0.997, N = 16). The absolute and relative error associated with the use of the ID and SC solution averaged 0.9mg/l DC and 7.0% and 0.6 mg/l DC and 9.6%, respectively. The precision of DC estimates established in a second test series was good; coefficients of variation (100(SD/mean)) for the head space (ID) and titration analyses were 0.99% and 1.7%. Precision of the SC solution method was 1.3%. In a third test series, a single ID was coupled with four replicate head space units so as to permit sequential monitoring (15 min intervals) of a common water source. Here, appropriate gas samples were secured using a series of solenoid valves (1.6 mm bore) activated by a time-based controller. This system configuration reduced the capital cost per sample site from US$ 2695 to 876. Absolute error averaged 2.9, 3.1, 3.7, and 2.7 mg/ l for replicates 1-4 (N = 36) during a 21-day test period (DC range, 36-40 mg/l). The ID meter was then modified so as to provide for DO as well as DC measurements across components of an intensive fish production system. ?? 2003 Elsevier B.V. All rights reserved.
Auvinen, Anssi; Moss, Sue M; Tammela, Teuvo L J; Taari, Kimmo; Roobol, Monique J; Schröder, Fritz H; Bangma, Chris H; Carlsson, Sigrid; Aus, Gunnar; Zappa, Marco; Puliti, Donella; Denis, Louis J; Nelen, Vera; Kwiatkowski, Maciej; Randazzo, Marco; Paez, Alvaro; Lujan, Marcos; Hugosson, Jonas
2016-01-01
Purpose The balance of benefits and harms in prostate cancer screening has not been sufficiently characterized. We related indicators of mortality reduction and overdetection by center within the European Randomized Study of Prostate Cancer Screening. Experimental Design We analyzed the absolute mortality reduction expressed as number needed to invite (NNI=1/absolute risk reduction; indicating how many men had to be randomized to screening arm to avert a prostate cancer death) for screening and the absolute excess of prostate cancer detection as number needed for overdetection (NNO=1/absolute excess incidence; indicating the number of men invited per additional prostate cancer case), and compared their relationship across the seven ERSPC centers. Results Both absolute mortality reduction (NNI) and absolute overdetection (NNO) varied widely between the centers: NNI 200-7000 and NNO 16-69. Extent of overdiagnosis and mortality reduction were closely associated (correlation coefficient r=0.76, weighted linear regression coefficient β=33, 95% 5-62, R2=0.72). For an averted prostate cancer death at 13 years of follow-up, 12-36 excess cases had to be detected in various centers. Conclusions The differences between the ERSPC centers likely reflect variations in prostate cancer incidence and mortality, as well as in screening protocol and performance. The strong interrelation between the benefits and harms suggests that efforts to maximize the mortality effect are bound to increase overdiagnosis, and might be improved by focusing on high-risk populations. The optimal balance between screening intensity and risk of overdiagnosis remains unclear. PMID:26289069
Sharp, Adam L.; Huang, Brian Z.; Tang, Tania; Shen, Ernest; Melnick, Edward R.; Venkatesh, Arjun K.; Kanter, Michael H.; Gould, Michael K.
2018-01-01
Study objective Approximately 1 in 3 computed tomography (CT) scans performed for head injury may be avoidable. We evaluate the association of implementation of the Canadian CT Head Rule on head CT imaging in community emergency departments (EDs). Methods We conducted an interrupted time-series analysis of encounters from January 2014 to December 2015 in 13 Southern California EDs. Adult health plan members with a trauma diagnosis and Glasgow Coma Scale score at ED triage were included. A multicomponent intervention included clinical leadership endorsement, physician education, and integrated clinical decision support. The primary outcome was the proportion of patients receiving a head CT. The unit of analysis was ED encounter, and we compared CT use pre- and postintervention with generalized estimating equations segmented logistic regression, with physician as a clustering variable. Secondary analysis described the yield of identified head injuries pre- and postintervention. Results Included were 44,947 encounters (28,751 preintervention and 16,196 postintervention), resulting in 14,633 (32.6%) head CTs (9,758 preintervention and 4,875 postintervention), with an absolute 5.3% (95% confidence interval [CI] 2.5% to 8.1%) reduction in CT use postintervention. Adjusted pre-post comparison showed a trend in decreasing odds of imaging (odds ratio 0.98; 95% CI 0.96 to 0.99). All but one ED reduced CTs postintervention (0.3% to 8.7%, one ED 0.3% increase), but no interaction between the intervention and study site over time existed (P=.34). After the intervention, diagnostic yield of CT-identified intracranial injuries increased by 2.3% (95% CI 1.5% to 3.1%). Conclusion A multicomponent implementation of the Canadian CT Head Rule was associated with a modest reduction in CT use and an increased diagnostic yield of head CTs for adult trauma encounters in community EDs. PMID:28739290
Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline
2013-06-01
What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Systematic review with meta-analysis of reliability studies. Any clinical population that has undergone assessment with the Berg Balance Scale. Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. Copyright © 2013 Australian Physiotherapy Association. Published by .. All rights reserved.
Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian
2013-01-01
Background Inertial measurement of motion with Attitude and Heading Reference Systems (AHRS) is emerging as an alternative to 3D motion capture systems in biomechanics. The objectives of this study are: 1) to describe the absolute and relative accuracy of multiple units of commercially available AHRS under various types of motion; and 2) to evaluate the effect of motion velocity on the accuracy of these measurements. Methods The criterion validity of accuracy was established under controlled conditions using an instrumented Gimbal table. AHRS modules were carefully attached to the center plate of the Gimbal table and put through experimental static and dynamic conditions. Static and absolute accuracy was assessed by comparing the AHRS orientation measurement to those obtained using an optical gold standard. Relative accuracy was assessed by measuring the variation in relative orientation between modules during trials. Findings Evaluated AHRS systems demonstrated good absolute static accuracy (mean error < 0.5o) and clinically acceptable absolute accuracy under condition of slow motions (mean error between 0.5o and 3.1o). In slow motions, relative accuracy varied from 2o to 7o depending on the type of AHRS and the type of rotation. Absolute and relative accuracy were significantly affected (p<0.05) by velocity during sustained motions. The extent of that effect varied across AHRS. Interpretation Absolute and relative accuracy of AHRS are affected by environmental magnetic perturbations and conditions of motions. Relative accuracy of AHRS is mostly affected by the ability of all modules to locate the same global reference coordinate system at all time. Conclusions Existing AHRS systems can be considered for use in clinical biomechanics under constrained conditions of use. While their individual capacity to track absolute motion is relatively consistent, the use of multiple AHRS modules to compute relative motion between rigid bodies needs to be optimized according to the conditions of operation. PMID:24260324
McGrew, Patrick R; Chestovich, Paul J; Fisher, Jay D; Kuhls, Deborah A; Fraser, Douglas R; Patel, Purvi P; Katona, Chad W; Saquib, Syed; Fildes, John J
2018-05-04
Computed Tomography (CT) scans are useful in the evaluation of trauma patients, but are costly and pose risks from ionizing radiation in children. Recent literature has demonstrated the utility of CT scan guidelines in the management of pediatric trauma. This study objective is to review our treatment of pediatric blunt trauma patients and evaluate CT utilization before and after CT-guideline implementation. Our Pediatric Level 2 Trauma Center (TC) implemented a CT scan practice guideline for pediatric trauma patients in March 2014. The guideline recommended for or against CT of the head and abdomen/pelvis utilizing published criteria from the Pediatric Emergency Care and Research Network (PECARN). There was no chest CT guideline. We reviewed all pediatric trauma patients for CT scans obtained during initial evaluation before and after guideline implementation, excluding inpatient scans. The Trauma Registry Database was queried to include all pediatric (age<15) trauma patients seen in our TC from 2010-2016, excluding penetrating mechanism and deaths in the TC. Scans were considered positive if organ injury was detected. Primary outcome was the proportion of patients undergoing CT and percent positive CTs. Secondary outcomes were hospital length of stay (LOS), readmissions, and mortality. Categorical and continuous variables were analyzed with Chi-square and Wilcoxon rank-sum tests, respectively. P<0.05 was considered significant. We identified 1934 patients: 1106 pre- and 828 post-guideline. Absolute reductions in head, chest, and abdomen/pelvis CT scans were 17.7%, 11.5%, and 18.8% respectively (p<0.001). Percent positive head CTs were equivalent, but percent positive chest and abdomen CT increased after implementation. Secondary outcomes were unchanged. Implementation of a pediatric CT guideline significantly decreases CT utilization, reducing the radiation exposure without a difference in outcome. Trauma centers treating pediatric patients should adopt similar guidelines to decrease unnecessary CT scans in children. Level IV, Therapeutic Study.
Tan, Yinghui; Zhou, Shuxia; Jiang, Hetian
2002-05-01
In this experiment, we studied the craniocerebral injury that occurs due to the transmission of forces when maxillofacial gunshot wounds are sustained by the facial bones and cranium. Forty fresh pigs' heads were wounded by one of the following methods: steel spheres weighing 1.03 g at an impact velocity of 1,400 m/s, steel spheres weighing 1.03 g at an impact velocity of 800 m/s, M193 military bullets, or M56 military bullets. Pressure waves in the brain, acceleration of the head, and stress changes in the facial bones and cranium at the moment of the impact were recorded by pressure and acceleration transducers and strain gauges and were statistically compared. Some obvious differences between the mechanical values obtained from high-and low-velocity missile wounds were found. A negative relationship between the peak value of the pressure wave in the brain and the distance from the point of impact to the transducer was obtained. The acceleration of the head in the direction of the ballistic path was the strongest in absolute value. There were differences in the stress values between the mandible and the temporal bone. Acceleration of the head, pressure wave changes in the brain, and injury from bony stress conduction all play important roles in associated craniocerebral damage after maxillofacial firearm wounds. Copyright 2002 American Association of Oral and Maxillofacial Surgeons
Onboard Autonomous Corrections for Accurate IRF Pointing.
NASA Astrophysics Data System (ADS)
Jorgensen, J. L.; Betto, M.; Denver, T.
2002-05-01
Over the past decade, the Noise Equivalent Angle (NEA) of onboard attitude reference instruments, has decreased from tens-of-arcseconds to the sub-arcsecond level. This improved performance is partly due to improved sensor-technology with enhanced signal to noise ratios, partly due to improved processing electronics which allows for more sophisticated and faster signal processing. However, the main reason for the increased precision, is the application of onboard autonomy, which apart from simple outlier rejection also allows for removal of "false positive" answers, and other "unexpected" noise sources, that otherwise would degrade the quality of the measurements (e.g. discrimination between signals caused by starlight and ionizing radiation). The utilization of autonomous signal processing has also provided the means for another onboard processing step, namely the autonomous recovery from lost in space, where the attitude instrument without a priori knowledge derive the absolute attitude, i.e. in IRF coordinates, within fractions of a second. Combined with precise orbital state or position data, the absolute attitude information opens for multiple ways to improve the mission performance, either by reducing operations costs, by increasing pointing accuracy, by reducing mission expendables, or by providing backup decision information in case of anomalies. The Advanced Stellar Compass's (ASC) is a miniature, high accuracy, attitude instrument which features fully autonomous operations. The autonomy encompass all direct steps from automatic health checkout at power-on, over fully automatic SEU and SEL handling and proton induced sparkle removal, to recovery from "lost in space", and optical disturbance detection and handling. But apart from these more obvious autonomy functions, the ASC also features functions to handle and remove the aforementioned residuals. These functions encompass diverse operators such as a full orbital state vector model with automatic cloud filtered GPS updates, a world time clock, astrometric correction tables, and a attitude output transform system, that allow the ASC to deliver the spacecraft attitude relative to the Inertial Reference Frame (IRF) in realtime. This paper describes the operations of the onboard autonomy of the ASC, which in realtime removes the residuals from the attitude measurements, whereby a timely IRF attitude at arcsecond level, is delivered to the AOCS (or sent to ground). A discussion about achievable robustness and accuracy is given, and compared to inflight results from the operations of the two Advanced Stellar Compass's (ASC), which are flying in LEO onboard the German geo-potential research satellite CHAMP. The ASC's onboard CHAMP are dual head versions, i.e. each processing unit is attached to two star camera heads. The dual head configuration is primarily employed to achieve a carefree AOCS control with respect to the Sun, Moon and Earth, and to increase the attitude accuracy, but it also enables onboard estimation and removal of thermal generated biases.
Changes in Pacific Absolute Plate Motion and Formation of Oceanic Flood Basalt Plateaus
NASA Astrophysics Data System (ADS)
Kroenke, L. W.; Wessel, P.
2006-12-01
The origin of the large oceanic flood basalt plateaus that are prominent features of the central western Pacific Basin remains unclear. Major changes in Pacific Absolute Plate Motion (APM) have been identified as occurring at 145, 125, 96, and 47 Ma. Formation of the Shatsky Rise (~145 Ma), the Ontong Java Plateau (122+ Ma), the Southern Hess Rise (95±5 Ma), and the Louisiade Plateau (~48 Ma) appear to coincide with these changes. A smaller, but still prominent change in Pacific APM also occurred at 110 Ma when the Northern Hess Rise formed. Although these concurrent events may simply be chance occurrences, initiation of plate tectonic reorganizations upon arrival of mantle plume heads also was proposed by Ratcliff et al. (1998), who suggested that the mantle plume head delivery of hot material to produce flood basalts also had the potential to trigger reorganizations of plate motions. It should be noted, however, that Pacific Rim subduction zone development also coincides with these APM changes, and that the actual cause and effect of each change in APM has yet to be clearly established. Here we present a modified Pacific APM model that uses several older seamount chains (Musicians, Ratak-Gilbert-Ellice, the Wake trails, and the Liliuokalani trails) to constrain the oldest Pacific plate motion using the hybrid technique of Wessel et al (2006).
Detection of bacterial pathogens in clade E head lice collected from Niger's refugees in Algeria.
Louni, Meriem; Amanzougaghene, Nadia; Mana, Nassima; Fenollar, Florence; Raoult, Didier; Bitam, Idir; Mediannikov, Oleg
2018-06-15
Head lice, Pediculus humanus capitis, are obligate blood-sucking parasites. Phylogenetically, they occur in five divergent mitochondrial clades (A, D, B, C and E), each having a particular geographical distribution. Recent studies have revealed that head lice, as is the case of body lice, can act as a vector for louse-borne diseases. Here, we aimed to study the genetic diversity of head lice collected from Niger's refugees (migrant population) arriving in Algeria, northern Africa, and to look for louse-borne pathogens. Comparative head lice samples collected from indigenous population of schoolchildren (non-immigrant) were also analyzed to frame the study. In this study, 37 head lice samples were collected from 31 Nigerien refugees, as well as 45 head lice from 27 schoolchildren. The collection was established in three localities of eastern Algiers, north Algeria. Quantitative real-time PCR screening of pathogens bacteria and the genetic characterisation of the head lice satut were performed. Through amplification and sequencing of the cytb gene, results showed that all head lice of Nigerien refugees 37/82 (45.12%) belonged to clade E with the presence of four new haplotypes, while, of the 45 head lice of schoolchildren, 34/82 lice (41.46%) belonged to clade A and 11/82 (13.41%) belonged to clade B. Our study is the first to report the existence of clade E haplogroup in Nigerien head lice. DNA of Coxiella burnetii was detected in 3/37 (8.10%) of the head lice collected from 3 of the 31 (9.67%) migrant population. We also revealed the presence of Acinetobacter DNA in 20/37 (54.05%) of head lice collected from 25/31 (80.64%) of the Nigerien refugees, and in 25/45 (55.55%) head lice collected from 15/27 (55.55%) schoolchildren. All positive Nigerien-head lice for Acinetobacter spp. were identified as A. baumannii, while positive schoolchildren-head lice were identified as A. johnsonii 15/25 (60%), A. variabilis 8/25 (32%) and A. baumannii 2/25 (8%). Based on these findings from head lice collected on migrant and non-migrant population, our results show, for the first time, that head lice from Niger belong to haplogroup E, and confirm that the clade E had a west African distribution. We also detected, for the first time, the presence of C. burnetii and A. baumannii in these Nigerien head lice. Nevertheless, further studies are needed to determine whether the head lice can transmit these pathogenic bacteria from one person to another.
Resting-State Oscillatory Activity in Children Born Small for Gestational Age: An MEG Study
Boersma, Maria; de Bie, Henrica M. A.; Oostrom, Kim J.; van Dijk, Bob W.; Hillebrand, Arjan; van Wijk, Bernadette C. M.; Delemarre-van de Waal, Henriëtte A.; Stam, Cornelis J.
2013-01-01
Growth restriction in utero during a period that is critical for normal growth of the brain, has previously been associated with deviations in cognitive abilities and brain anatomical and functional changes. We measured magnetoencephalography (MEG) in 4- to 7-year-old children to test if children born small for gestational age (SGA) show deviations in resting-state brain oscillatory activity. Children born SGA with postnatally spontaneous catch-up growth [SGA+; six boys, seven girls; mean age 6.3 year (SD = 0.9)] and children born appropriate for gestational age [AGA; seven boys, three girls; mean age 6.0 year (SD = 1.2)] participated in a resting-state MEG study. We calculated absolute and relative power spectra and used non-parametric statistics to test for group differences. SGA+ and AGA born children showed no significant differences in absolute and relative power except for reduced absolute gamma band power in SGA children. At the time of MEG investigation, SGA+ children showed significantly lower head circumference (HC) and a trend toward lower IQ, however there was no association of HC or IQ with absolute or relative power. Except for reduced absolute gamma band power, our findings suggest normal brain activity patterns at school age in a group of children born SGA in which spontaneous catch-up growth of bodily length after birth occurred. Although previous findings suggest that being born SGA alters brain oscillatory activity early in neonatal life, we show that these neonatal alterations do not persist at early school age when spontaneous postnatal catch-up growth occurs after birth. PMID:24068993
De la Corte-Rodriguez, Hortensia; Rodriguez-Merchan, E Carlos; Alvarez-Roman, M Teresa; Martin-Salces, Mónica; Martinoli, Carlo; Jimenez-Yuste, Víctor
2018-03-01
Prevention of hemarthrosis is the key factor in the adequate management of people with hemophilia (PWH). If hemarthrosis occurs, early diagnosis of joint damage is essential to make personalized treatments. This study is aimed at gaining an understanding of the ability of point-of-care ultrasound (US) using the `Hemophilia Early Arthropathy Detection with Ultrasound´ (HEAD-US) protocol to detect abnormalities in joints without history of hemarthrosis and clinically asymptomatic joints of PWH. The sample included 976 joints from 167 PWH (mean age 24.86 years). Data were collected from routine practice over a 3-year period and analyzed based on history of hemarthrosis and results of clinical (HJHS 2.1) and HEAD-US examinations. In our series, 14% of patients exhibited HEAD-US signs of incipient arthropathy in joints with no history of bleeding and with a HJHS 2.1 score of 0. The most severely involved joint was the right ankle. Synovitis, articular cartilage and subchondral bone damage scores in joints with subclinical findings were slower than in joints with previous hemarthroses or HJHS 2.1 > 1 Conclusions: Our study demonstrates that HEAD-US is better than hemarthrosis records and the HJHS 2.1 scale in detecting the early signs of joint damage in PWH.
Mobashsher, Ahmed Toaha; Mahmoud, A.; Abbosh, A. M.
2016-01-01
Intracranial hemorrhage is a medical emergency that requires rapid detection and medication to restrict any brain damage to minimal. Here, an effective wideband microwave head imaging system for on-the-spot detection of intracranial hemorrhage is presented. The operation of the system relies on the dielectric contrast between healthy brain tissues and a hemorrhage that causes a strong microwave scattering. The system uses a compact sensing antenna, which has an ultra-wideband operation with directional radiation, and a portable, compact microwave transceiver for signal transmission and data acquisition. The collected data is processed to create a clear image of the brain using an improved back projection algorithm, which is based on a novel effective head permittivity model. The system is verified in realistic simulation and experimental environments using anatomically and electrically realistic human head phantoms. Quantitative and qualitative comparisons between the images from the proposed and existing algorithms demonstrate significant improvements in detection and localization accuracy. The radiation and thermal safety of the system are examined and verified. Initial human tests are conducted on healthy subjects with different head sizes. The reconstructed images are statistically analyzed and absence of false positive results indicate the efficacy of the proposed system in future preclinical trials. PMID:26842761
NASA Astrophysics Data System (ADS)
Mobashsher, Ahmed Toaha; Mahmoud, A.; Abbosh, A. M.
2016-02-01
Intracranial hemorrhage is a medical emergency that requires rapid detection and medication to restrict any brain damage to minimal. Here, an effective wideband microwave head imaging system for on-the-spot detection of intracranial hemorrhage is presented. The operation of the system relies on the dielectric contrast between healthy brain tissues and a hemorrhage that causes a strong microwave scattering. The system uses a compact sensing antenna, which has an ultra-wideband operation with directional radiation, and a portable, compact microwave transceiver for signal transmission and data acquisition. The collected data is processed to create a clear image of the brain using an improved back projection algorithm, which is based on a novel effective head permittivity model. The system is verified in realistic simulation and experimental environments using anatomically and electrically realistic human head phantoms. Quantitative and qualitative comparisons between the images from the proposed and existing algorithms demonstrate significant improvements in detection and localization accuracy. The radiation and thermal safety of the system are examined and verified. Initial human tests are conducted on healthy subjects with different head sizes. The reconstructed images are statistically analyzed and absence of false positive results indicate the efficacy of the proposed system in future preclinical trials.
Sharma, Shilpi; Chaukar, Devendra A
2014-07-01
Head neck cancer is an important health problem with high morbidity and mortality. Early detection and adequate treatment improve prognosis significantly. Thus creating awareness among clinicians is an important step toward control of head neck cancer and reducing its overall burden. We here provide an update on the International Federation of Head Neck Oncology Society/American Head Neck Society 2014 held between July 26, 2014 and July 30, 2014 in New York.
Kempf, Marie; Abdissa, Alemseged; Diatta, Georges; Trape, Jean-François; Angelakis, Emmanouil; Mediannikov, Oleg; La Scola, Bernard; Raoult, Didier
2012-09-01
Acinetobacter baumannii has previously been detected and genotyped in human body lice. The objectives of this study were to determine the presence of this bacterium in head and body lice collected from healthy individuals in Ethiopia by molecular methods and to characterize the genotype. Human lice from locations at different altitudes in Ethiopia were screened for the presence of Acinetobacter sp by targeting the rpoB gene. Acinetobacter baumannii was detected and genotyped using recA PCR amplification. A total of 115 head and 109 body lice were collected from 134 healthy individuals. Acinetobacter sp were found in 54 head (47%) and 77 body (71%) lice. The recA gene was sequenced for 60 of the Acinetobacter sp and 67% were positive for A. baumannii; genotype 1 was retrieved the most frequently. Our study is the first to show the presence of A. baumannii in human body lice, and also in head lice, in Ethiopia. Copyright © 2012 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2011 CFR
2011-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
40 CFR 1065.345 - Vacuum-side leak verification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... zero flow, or by detecting the dilution of a known concentration of span gas when it flows through the.... Measure and record the absolute pressure of the trapped gas and optionally the system absolute temperature... pressure and optionally temperature. (4) Calculate the leak flow rate based on an assumed value of zero for...
NASA Astrophysics Data System (ADS)
Lukianova-Hleb, Ekaterina Y.; Kim, Yoo-Shin; Belatsarkouski, Ihar; Hanna, Ehab Y.; Gillenwater, Ann M.; O'Neill, Brian; Lapotko, Dmitri
2016-02-01
Failure of cancer surgery to intraoperatively detect and eliminate microscopic residual disease (MRD) causes lethal recurrence and metastases, whereas removal of important normal tissues causes excessive morbidity. We report plasmonic nanobubble (PNB) surgical technology to intraoperatively detect and eliminate MRD in surgical bed. PNBs were generated in vivo in head and neck cancer cells by systemically targeting tumor with gold colloids and locally-applied near-infrared low energy short laser pulse, and were simultaneously detected with acoustic probe. In mouse models of head and neck squamous cell carcinoma, single cancer cells and MRD (undetectable with standard histological methods) were instantaneously non-invasively detected in solid tissue in surgical bed. In resectable MRD, PNB-guided surgery prevented local recurrence and delivered 100% tumor-free survival. In unresectable MRD, PNB nano-surgery improved survival by two-fold compared to standard surgery. PNB metrics correlated with the tumor recurrence rate. PNB surgical technology precisely detects and immediately eliminates MRD at macro- and micro-scale in a simple and safe intraoperative procedure.
NASA Technical Reports Server (NTRS)
Janches, D.; Hocking, W.; Pifko, S.; Hormaechea, J. L.; Fritts, D. C.; Brunini, C; Michell, R.; Samara, M.
2013-01-01
A radar meteor echo is the radar scattering signature from the free-electrons in a plasma trail generated by entry of extraterrestrial particles into the atmosphere. Three categories of scattering mechanisms exist: specular, nonspecular trails, and head-echoes. Generally, there are two types of radars utilized to detect meteors. Traditional VHF meteor radars (often called all-sky1radars) primarily detect the specular reflection of meteor trails traveling perpendicular to the line of sight of the scattering trail, while High Power and Large Aperture (HPLA) radars efficiently detect meteor head-echoes and, in some cases, non-specular trails. The fact that head-echo measurements can be performed only with HPLA radars limits these studies in several ways. HPLA radars are very sensitive instruments constraining the studies to the lower masses, and these observations cannot be performed continuously because they take place at national observatories with limited allocated observing time. These drawbacks can be addressed by developing head echo observing techniques with modified all-sky meteor radars. In addition, the fact that the simultaneous detection of all different scattering mechanisms can be made with the same instrument, rather than requiring assorted different classes of radars, can help clarify observed differences between the different methodologies. In this study, we demonstrate that such concurrent observations are now possible, enabled by the enhanced design of the Southern Argentina Agile Meteor Radar (SAAMER) deployed at the Estacion Astronomica Rio Grande (EARG) in Tierra del Fuego, Argentina. The results presented here are derived from observations performed over a period of 12 days in August 2011, and include meteoroid dynamical parameter distributions, radiants and estimated masses. Overall, the SAAMER's head echo detections appear to be produced by larger particles than those which have been studied thus far using this technique.
An eye model for uncalibrated eye gaze estimation under variable head pose
NASA Astrophysics Data System (ADS)
Hnatow, Justin; Savakis, Andreas
2007-04-01
Gaze estimation is an important component of computer vision systems that monitor human activity for surveillance, human-computer interaction, and various other applications including iris recognition. Gaze estimation methods are particularly valuable when they are non-intrusive, do not require calibration, and generalize well across users. This paper presents a novel eye model that is employed for efficiently performing uncalibrated eye gaze estimation. The proposed eye model was constructed from a geometric simplification of the eye and anthropometric data about eye feature sizes in order to circumvent the requirement of calibration procedures for each individual user. The positions of the two eye corners and the midpupil, the distance between the two eye corners, and the radius of the eye sphere are required for gaze angle calculation. The locations of the eye corners and midpupil are estimated via processing following eye detection, and the remaining parameters are obtained from anthropometric data. This eye model is easily extended to estimating eye gaze under variable head pose. The eye model was tested on still images of subjects at frontal pose (0 °) and side pose (34 °). An upper bound of the model's performance was obtained by manually selecting the eye feature locations. The resulting average absolute error was 2.98 ° for frontal pose and 2.87 ° for side pose. The error was consistent across subjects, which indicates that good generalization was obtained. This level of performance compares well with other gaze estimation systems that utilize a calibration procedure to measure eye features.
NASA Astrophysics Data System (ADS)
van den Heuvel, Thomas L. A.; Petros, Hezkiel; Santini, Stefano; de Korte, Chris L.; van Ginneken, Bram
2017-03-01
Worldwide, 99% of all maternal deaths occur in low-resource countries. Ultrasound imaging can be used to detect maternal risk factors, but requires a well-trained sonographer to obtain the biometric parameters of the fetus. One of the most important biometric parameters is the fetal Head Circumference (HC). The HC can be used to estimate the Gestational Age (GA) and assess the growth of the fetus. In this paper we propose a method to estimate the fetal HC with the use of the Obstetric Sweep Protocol (OSP). With the OSP the abdomen of pregnant women is imaged with the use of sweeps. These sweeps can be taught to somebody without any prior knowledge of ultrasound within a day. Both the OSP and the standard two-dimensional ultrasound image for HC assessment were acquired by an experienced gynecologist from fifty pregnant women in St. Luke's Hospital in Wolisso, Ethiopia. The reference HC from the standard two-dimensional ultrasound image was compared to both the manually measured HC and the automatically measured HC from the OSP data. The median difference between the estimated GA from the manual measured HC using the OSP and the reference standard was -1.1 days (Median Absolute Deviation (MAD) 7.7 days). The median difference between the estimated GA from the automatically measured HC using the OSP and the reference standard was -6.2 days (MAD 8.6 days). Therefore, it can be concluded that it is possible to estimate the fetal GA with simple obstetric sweeps with a deviation of only one week.
Finite-frequency sensitivity kernels for head waves
NASA Astrophysics Data System (ADS)
Zhang, Zhigang; Shen, Yang; Zhao, Li
2007-11-01
Head waves are extremely important in determining the structure of the predominantly layered Earth. While several recent studies have shown the diffractive nature and the 3-D Fréchet kernels of finite-frequency turning waves, analogues of head waves in a continuous velocity structure, the finite-frequency effects and sensitivity kernels of head waves are yet to be carefully examined. We present the results of a numerical study focusing on the finite-frequency effects of head waves. Our model has a low-velocity layer over a high-velocity half-space and a cylindrical-shaped velocity perturbation placed beneath the interface at different locations. A 3-D finite-difference method is used to calculate synthetic waveforms. Traveltime and amplitude anomalies are measured by the cross-correlation of synthetic seismograms from models with and without the velocity perturbation and are compared to the 3-D sensitivity kernels constructed from full waveform simulations. The results show that the head wave arrival-time and amplitude are influenced by the velocity structure surrounding the ray path in a pattern that is consistent with the Fresnel zones. Unlike the `banana-doughnut' traveltime sensitivity kernels of turning waves, the traveltime sensitivity of the head wave along the ray path below the interface is weak, but non-zero. Below the ray path, the traveltime sensitivity reaches the maximum (absolute value) at a depth that depends on the wavelength and propagation distance. The sensitivity kernels vary with the vertical velocity gradient in the lower layer, but the variation is relatively small at short propagation distances when the vertical velocity gradient is within the range of the commonly accepted values. Finally, the depression or shoaling of the interface results in increased or decreased sensitivities, respectively, beneath the interface topography.
A game-theoretic approach for calibration of low-cost magnetometers under noise uncertainty
NASA Astrophysics Data System (ADS)
Siddharth, S.; Ali, A. S.; El-Sheimy, N.; Goodall, C. L.; Syed, Z. F.
2012-02-01
Pedestrian heading estimation is a fundamental challenge in Global Navigation Satellite System (GNSS)-denied environments. Additionally, the heading observability considerably degrades in low-speed mode of operation (e.g. walking), making this problem even more challenging. The goal of this work is to improve the heading solution when hand-held personal/portable devices, such as cell phones, are used for positioning and to improve the heading estimation in GNSS-denied signal environments. Most smart phones are now equipped with self-contained, low cost, small size and power-efficient sensors, such as magnetometers, gyroscopes and accelerometers. A magnetometer needs calibration before it can be properly employed for navigation purposes. Magnetometers play an important role in absolute heading estimation and are embedded in many smart phones. Before the users navigate with the phone, a calibration is invoked to ensure an improved signal quality. This signal is used later in the heading estimation. In most of the magnetometer-calibration approaches, the motion modes are seldom described to achieve a robust calibration. Also, suitable calibration approaches fail to discuss the stopping criteria for calibration. In this paper, the following three topics are discussed in detail that are important to achieve proper magnetometer-calibration results and in turn the most robust heading solution for the user while taking care of the device misalignment with respect to the user: (a) game-theoretic concepts to attain better filter parameter tuning and robustness in noise uncertainty, (b) best maneuvers with focus on 3D and 2D motion modes and related challenges and (c) investigation of the calibration termination criteria leveraging the calibration robustness and efficiency.
Saranya, Raju; Aarthi, Raju; Sankaran, Krishnan
2015-05-01
Spread of drug-resistant Staphylococcus spp. into communities pose danger demanding effective non-invasive and non-destructive tools for its early detection and surveillance. Characteristic volatile organic compounds (VOCs) produced by bacteria offer new diagnostic targets and novel approaches not exploited so far in infectious disease diagnostics. Our search for such characteristic VOC for Staphylococcus spp. led to the depiction of 2-[3-acetoxy-4,4,14-trimethylandrost-8-en-17-yl] propanoic acid (ATMAP), a moderately volatile compound detected both in the culture and headspace when the organism was grown in tryptone soya broth (TSB) medium. A simple and inexpensive colorimetric method (colour change from yellow to orange) using methyl red as the pH indicator provided an absolutely specific way for identifying Staphylococcus spp., The assay performed in liquid cultures (7-h growth in TSB) as well as in the headspace of plate cultures (grown for 10 h on TSA) was optimised in a 96-well plate and 12-well plate formats, respectively, employing a set of positive and negative strains. Only Staphylococcus spp. showed the distinct colour change from yellow to orange due to the production of the above VOC while in the case of other organisms, the reagent remained yellow. The method validated using known clinical and environmental strains (56 including Staphylococcus, Proteus, Pseudomonas, Klebsiella, Bacillus, Shigella and Escherichia coli) was found to be highly efficient showing 100% specificity and sensitivity. Such simple methods of bacterial pathogen identification are expected to form the next generation tools for the control of infectious diseases through early detection and surveillance of causative agents.
John, G C; Nduati, R W; Mbori-Ngacha, D; Overbaugh, J; Welch, M; Richardson, B A; Ndinya-Achola, J; Bwayo, J; Krieger, J; Onyango, F; Kreiss, J K
1997-01-01
The presence of human immunodeficiency virus type 1 (HIV-1) in genital secretions may be a determinant of vertical HIV-1 transmission. Cervical and vaginal secretions from HIV-1-seropositive pregnant women were evaluated to determine prevalence and correlates of HIV-1-infected cells in the genital tract. HIV-1 DNA was detected by polymerase chain reaction in 32% of 212 cervical and 10% of 215 vaginal specimens. Presence of HIV-1 DNA in the cervix was associated with cervical mucopus and a significantly lower absolute CD4 cell count (354 vs. 469, P < .001). An absolute CD4 cell count <200 was associated with a 9.6-fold increased odds of cervical HIV-1 DNA detection compared with a count > or = 500 (95% confidence interval, 2.8-34.2). Detection of vaginal HIV- 1 DNA was associated with abnormal vaginal discharge, lower absolute CD4 cell count, and severe vitamin A deficiency. Presence of HIV-1-infected cells in genital secretions was associated with immunosuppression and abnormal cervical or vaginal discharge.
NASA Astrophysics Data System (ADS)
Brown, P.; Stober, G.; Schult, C.; Krzeminski, Z.; Cooke, W.; Chau, J. L.
2017-07-01
The initial results of a two year simultaneous optical-radar meteor campaign are described. Analysis of 105 double-station optical meteors having plane of sky intersection angles greater than 5° and trail lengths in excess of 2 km also detected by the Middle Atmosphere Alomar Radar System (MAARSY) as head echoes was performed. These events show a median deviation in radiants between radar and optical determinations of 1.5°, with 1/3 of events having radiant agreement to less than one degree. MAARSY tends to record average speeds roughly 0.5 km/s and 1.3 km higher than optical records, in part due to the higher sensitivity of MAARSY as compared to the optical instruments. More than 98% of all head echoes are not detected with the optical system. Using this non-detection ratio and the known limiting sensitivity of the cameras, we estimate that the limiting meteoroid detection mass of MAARSY is in the 10-9-10-10 kg (astronomical limiting meteor magnitudes of +11 to +12) appropriate to speeds from 30 to 60 km/s. There is a clear trend of higher peak RCS for brighter meteors between 35 and -30 dBsm. For meteors with similar magnitudes, the MAARSY head echo radar cross-section is larger at higher speeds. Brighter meteors at fixed heights and similar speeds have consistently, on average, larger RCS values, in accordance with established scattering theory. However, our data show RCS ∝ v/2, much weaker than the normally assumed RCS ∝ v3, a consequence of our requiring head echoes to also be detectable optically. Most events show a smooth variation of RCS with height broadly following the light production behavior. A significant minority of meteors show large variations in RCS relative to the optical light curve over common height intervals, reflecting fragmentation or possibly differential ablation. No optically detected meteor occurring in the main radar beam and at times when the radar was collecting head echo data went unrecorded by MAARSY. Thus there does not appear to be any large scale bias in MAARSY head echo detections for the (comparatively) larger optical events in our dataset, even at very low speeds.
Non-intrusive head movement analysis of videotaped seizures of epileptic origin.
Mandal, Bappaditya; Eng, How-Lung; Lu, Haiping; Chan, Derrick W S; Ng, Yen-Ling
2012-01-01
In this work we propose a non-intrusive video analytic system for patient's body parts movement analysis in Epilepsy Monitoring Unit. The system utilizes skin color modeling, head/face pose template matching and face detection to analyze and quantify the head movements. Epileptic patients' heads are analyzed holistically to infer seizure and normal random movements. The patient does not require to wear any special clothing, markers or sensors, hence it is totally non-intrusive. The user initializes the person-specific skin color and selects few face/head poses in the initial few frames. The system then tracks the head/face and extracts spatio-temporal features. Support vector machines are then used on these features to classify seizure-like movements from normal random movements. Experiments are performed on numerous long hour video sequences captured in an Epilepsy Monitoring Unit at a local hospital. The results demonstrate the feasibility of the proposed system in pediatric epilepsy monitoring and seizure detection.
Method and apparatus for ultra-high-sensitivity, incremental and absolute optical encoding
NASA Technical Reports Server (NTRS)
Leviton, Douglas B. (Inventor)
1999-01-01
An absolute optical linear or rotary encoder which encodes the motion of an object (3) with increased resolution and encoding range and decreased sensitivity to damage to the scale includes a scale (5), which moves with the object and is illuminated by a light source (11). The scale carries a pattern (9) which is imaged by a microscope optical system (13) on a CCD array (17) in a camera head (15). The pattern includes both fiducial markings (31) which are identical for each period of the pattern and code areas (33) which include binary codings of numbers identifying the individual periods of the pattern. The image of the pattern formed on the CCD array is analyzed by an image processor (23) to locate the fiducial marking, decode the information encoded in the code area, and thereby determine the position of the object.
NASA Technical Reports Server (NTRS)
Galvas, M. R.
1972-01-01
Centrifugal compressor performance was examined analytically to determine optimum geometry for various applications as characterized by specific speed. Seven specific losses were calculated for various combinations of inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, blade exit backsweep, and inlet-tip absolute tangential velocity for solid body prewhirl. The losses considered were inlet guide vane loss, blade loading loss, skin friction loss, recirculation loss, disk friction loss, vaneless diffuser loss, and vaned diffuser loss. Maximum total efficiencies ranged from 0.497 to 0.868 for a specific speed range of 0.257 to 1.346. Curves of rotor exit absolute flow angle, inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, head coefficient and blade exit backsweep are presented over a range of specific speeds for various inducer tip speeds to permit rapid selection of optimum compressor size and shape for a variety of applications.
NASA Astrophysics Data System (ADS)
Ko, Woo Seok; Darwish, Naser; Gratton, Enrico; Kim, Soo Hyun
2005-04-01
We measure the concentration of oxy-, deoxy- and total hemoglobin by using the frequency-domain, near-infrared spectroscopy(NIRS) scanner. It is a non-invasive instrument that can provide real-time measurements of the changes in concentration. It can provide a diagnostic tool for the study of the brain in infants and children. However, it is difficult to apply it to the baby's head because of the contact of the probe on the soft baby's head. Therefore, we suggest the NIRS scanning system that can track the baby' head movement and detect NIRS parameters on the same position of the head. This system has three key components. The vision system performs the pattern matching for tracking the head by using the normalized cross correlation method with the target as a cross-line on the head during the diagnostic experiment. We can use the change of the position of the baby's head to re-target the light by the scanning system that uses four laser sources, a wavelength selector, and an x-y scanner. The detector system analyzes the resulting signal from the head using the diffusion model. Therefore, NIRS scanning system can provide a diagnostic tool to measure the changes of the NIRS parameters for the study of the baby's brain.
An electromechanical, patient positioning system for head and neck radiotherapy
NASA Astrophysics Data System (ADS)
Ostyn, Mark; Dwyer, Thomas; Miller, Matthew; King, Paden; Sacks, Rachel; Cruikshank, Ross; Rosario, Melvin; Martinez, Daniel; Kim, Siyong; Yeo, Woon-Hong
2017-09-01
In cancer treatment with radiation, accurate patient setup is critical for proper dose delivery. Improper arrangement can lead to disease recurrence, permanent organ damage, or lack of disease control. While current immobilization equipment often helps for patient positioning, manual adjustment is required, involving iterative, time-consuming steps. Here, we present an electromechanical robotic system for improving patient setup in radiotherapy, specifically targeting head and neck cancer. This positioning system offers six degrees of freedom for a variety of applications in radiation oncology. An analytical calculation of inverse kinematics serves as fundamental criteria to design the system. Computational mechanical modeling and experimental study of radiotherapy compatibility and x-ray-based imaging demonstrates the device feasibility and reliability to be used in radiotherapy. An absolute positioning accuracy test in a clinical treatment room supports the clinical feasibility of the system.
Bäck, Leif J J; Aro, Katri; Tapiovaara, Laura; Vikatmaa, Pirkka; de Bree, Remco; Fernández-Álvarez, Verónica; Kowalski, Luiz P; Nixon, Iain J; Rinaldo, Alessandra; Rodrigo, Juan P; Robbins, K Thomas; Silver, Carl E; Snyderman, Carl H; Suárez, Carlos; Takes, Robert P; Ferlito, Alfio
2018-06-01
Sacrifice and reconstruction of the carotid artery in cases of head and neck carcinoma with invasion of the common or internal carotid artery is debated. We conducted a systematic search of electronic databases and provide a review and meta-analysis. Of the 72 articles identified, 24 met the inclusion criteria resulting in the inclusion of 357 patients. The overall perioperative 30-day mortality was 3.6% (13/357). Permanent cerebrovascular complications occurred in 3.6% (13/357). Carotid blowout episodes were encountered in 1.4% (5/357). The meta-regression analysis showed a significant difference in 1-year overall survival between reports published from 1981-1999 (37.0%) and 2001-2016 (65.4%; P = .02). This review provides evidence that sacrifice with extracranial reconstruction of common or internal carotid artery in selected patients with head and neck carcinoma may improve survival with acceptable complication rates. However, all of the published literature is retrospective involving selected series and, therefore, precludes determining the absolute effectiveness of the surgery. © 2018 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Suzuki, Yoichiro
2008-11-01
The personal view for the next to the next neutrino detector, the ultimate experiment, is discussed. Considering the size, cost and head winds against the basic science, the ultimate experiment will be the only experiment in the world. Here two such experiments one for the neutrino oscillation and the other for the double beta decay were discussed. The ultimate experiment needs to include a bread and butter science and to have a discovery potential for an unexpected phenomenon. There are many technical challenges and international co-operations are absolutely necessary.
Stoecker, William V.; Gupta, Kapil; Stanley, R. Joe; Moss, Randy H.; Shrestha, Bijaya
2011-01-01
Background Dermoscopy, also known as dermatoscopy or epiluminescence microscopy (ELM), is a non-invasive, in vivo technique, which permits visualization of features of pigmented melanocytic neoplasms that are not discernable by examination with the naked eye. One prominent feature useful for melanoma detection in dermoscopy images is the asymmetric blotch (asymmetric structureless area). Method Using both relative and absolute colors, blotches are detected in this research automatically by using thresholds in the red and green color planes. Several blotch indices are computed, including the scaled distance between the largest blotch centroid and the lesion centroid, ratio of total blotch areas to lesion area, ratio of largest blotch area to lesion area, total number of blotches, size of largest blotch, and irregularity of largest blotch. Results The effectiveness of the absolute and relative color blotch features was examined for melanoma/benign lesion discrimination over a dermoscopy image set containing 165 melanomas (151 invasive melanomas and 14 melanomas in situ) and 347 benign lesions (124 nevocellular nevi without dysplasia and 223 dysplastic nevi) using a leave-one-out neural network approach. Receiver operating characteristic curve results are shown, highlighting the sensitivity and specificity of melanoma detection. Statistical analysis of the blotch features are also presented. Conclusion Neural network and statistical analysis showed that the blotch detection method was somewhat more effective using relative color than using absolute color. The relative-color blotch detection method gave a diagnostic accuracy of about 77%. PMID:15998328
Takasaki, Hiroshi; Treleaven, Julia; Johnston, Venerina; Van den Hoorn, Wolbert; Rakotonirainy, Andry; Jull, Gwendolen
2014-08-01
Individuals with chronic whiplash-associated disorders (WADs) often note driving as a difficult task. This study's aims were to (1) compare, while driving, neck motor performance, mental effort, and fatigue in individuals with chronic WAD against healthy controls and (2) investigate the relationships of these variables and neck pain to self-reported driving difficulty in the WAD group. This study involved 14 participants in each group (WAD and control). Measures included self-reported driving difficulty and measures of neck pain intensity, overall fatigue, mental effort, and neck motor performance (head rotation and upper trapezius activity) while driving a simulator. The WAD group had greater absolute path of head rotation in a simulated city area and used greater mental effort (P = 0.04), but there were no differences in other measures while driving compared with the controls (all P ≥ 0.05). Self-reported driving difficulty correlated moderately with neck pain intensity, fatigue level, and maximum velocity of head rotation while driving in the WAD group (all P < 0.05). Individuals with chronic WAD do not seem to have impaired neck motor performance while driving yet use greater mental effort. Neck pain, fatigue, and maximum head rotation velocity could be potential contributors to self-reported driving difficulty in this group.
Tawadrous, Davy; Dixon, Stephanie; Shariff, Salimah Z; Fleet, Jamie; Gandhi, Sonja; Jain, Arsh K; Weir, Matthew A; Gomes, Tara; Garg, Amit X
2014-10-01
Standard doses of histamine2-receptor antagonists (H2RAs) may induce altered mental status in older adults, especially in those with chronic kidney disease (CKD). Population-based cohort study of older adults who started a new H2RA between 2002 and 2011 was conducted. Ninety percent received the current standard H2RA dose in routine care. There was no significant difference in 27 baseline patient characteristics. The primary outcome was hospitalization with an urgent head computed tomography (CT) scan (proxy for altered mental status), and the secondary outcome was all-cause mortality also within 30days of a new H2RA prescription. Standard vs. low H2RA dose was associated with a higher risk of hospitalization with an urgent head CT scan (0.98% vs. 0.74%, absolute risk difference 0.24% [95% CI 0.11% to 0.36%], relative risk 1.33 [95% CI 1.12 to 1.58]). This risk was not modified by the presence of CKD (interaction P value=0.71). Standard vs. low H2RA dose was associated with a higher risk of mortality (1.07% vs.0.74%; absolute risk difference 0.34% [95% CI 0.20% to 0.46%], relative risk 1.46 [95% CI 1.23 to 1.73]). Compared to a lower dose, initiation of the current standard dose of H2RA in older adults is associated with a small absolute increase in the 30-day risk of altered mental status (using neuroimaging as a proxy), even in the absence of CKD. This risk may be avoided by initiating older adults on low doses of H2RAs for gastroesophogeal reflux disease, and increasing dosing as necessary for symptom control. Copyright © 2014 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
De, Arijit K., E-mail: akde@lbl.gov; Fleming, Graham R., E-mail: grfleming@lbl.gov; Department of Chemistry, University of California at Berkeley, Berkeley, California 94702
2014-05-21
We present a novel experimental scheme for two-dimensional fluorescence-detected coherent spectroscopy (2D-FDCS) using a non-collinear beam geometry with the aid of “confocal imaging” of dynamic (population) grating and 27-step phase-cycling to extract the signal. This arrangement obviates the need for distinct experimental designs for previously developed transmission detected non-collinear two-dimensional coherent spectroscopy (2D-CS) and collinear 2D-FDCS. We also describe a novel method for absolute phasing of the 2D spectrum. We apply this method to record 2D spectra of a fluorescent dye in solution at room temperature and observe “spectral diffusion.”.
Silicon monoxide in the 4 micron infrared spectrum of long-period variables
NASA Technical Reports Server (NTRS)
Hinkle, K. H.; Barnes, T. G.; Lambert, D. L.; Beer, R.
1976-01-01
The first-overtone sequence of vibration-rotation transitions of the free radical silicon monoxide are shown to have extreme phase-dependent variations in the spectra of two M-type long-period variables, Omicron Ceti and R Leonis, and the mild S-type long-period variable, Chi Cygni. At maximum light, the SiO band heads are not detectable. Near minimum light, the band heads of (Si-25)O are detected in the 4-micron spectra of all three stars. The band heads of the terrestrially less abundant isotopic species, (Si-29)O and (Si-30)O, are detected in Chi Cygni. Possible explanations of the phase-dependent behavior are discussed, and the role of the stellar chromosphere is considered.
Maccabi, Ashkan; Shin, Andrew; Namiri, Nikan K; Bajwa, Neha; St John, Maie; Taylor, Zachary D; Grundfest, Warren; Saddik, George N
2018-01-01
Viscoelasticity of soft tissue is often related to pathology, and therefore, has become an important diagnostic indicator in the clinical assessment of suspect tissue. Surgeons, particularly within head and neck subsites, typically use palpation techniques for intra-operative tumor detection. This detection method, however, is highly subjective and often fails to detect small or deep abnormalities. Vibroacoustography (VA) and similar methods have previously been used to distinguish tissue with high-contrast, but a firm understanding of the main contrast mechanism has yet to be verified. The contributions of tissue mechanical properties in VA images have been difficult to verify given the limited literature on viscoelastic properties of various normal and diseased tissue. This paper aims to investigate viscoelasticity theory and present a detailed description of viscoelastic experimental results obtained in tissue-mimicking phantoms (TMPs) and ex vivo tissues to verify the main contrast mechanism in VA and similar imaging modalities. A spherical-tip micro-indentation technique was employed with the Hertzian model to acquire absolute, quantitative, point measurements of the elastic modulus (E), long term shear modulus (η), and time constant (τ) in homogeneous TMPs and ex vivo tissue in rat liver and porcine liver and gallbladder. Viscoelastic differences observed between porcine liver and gallbladder tissue suggest that imaging modalities which utilize the mechanical properties of tissue as a primary contrast mechanism can potentially be used to quantitatively differentiate between proximate organs in a clinical setting. These results may facilitate more accurate tissue modeling and add information not currently available to the field of systems characterization and biomedical research.
Shin, Andrew; Namiri, Nikan K.; Bajwa, Neha; St. John, Maie; Taylor, Zachary D.; Grundfest, Warren; Saddik, George N.
2018-01-01
Viscoelasticity of soft tissue is often related to pathology, and therefore, has become an important diagnostic indicator in the clinical assessment of suspect tissue. Surgeons, particularly within head and neck subsites, typically use palpation techniques for intra-operative tumor detection. This detection method, however, is highly subjective and often fails to detect small or deep abnormalities. Vibroacoustography (VA) and similar methods have previously been used to distinguish tissue with high-contrast, but a firm understanding of the main contrast mechanism has yet to be verified. The contributions of tissue mechanical properties in VA images have been difficult to verify given the limited literature on viscoelastic properties of various normal and diseased tissue. This paper aims to investigate viscoelasticity theory and present a detailed description of viscoelastic experimental results obtained in tissue-mimicking phantoms (TMPs) and ex vivo tissues to verify the main contrast mechanism in VA and similar imaging modalities. A spherical-tip micro-indentation technique was employed with the Hertzian model to acquire absolute, quantitative, point measurements of the elastic modulus (E), long term shear modulus (η), and time constant (τ) in homogeneous TMPs and ex vivo tissue in rat liver and porcine liver and gallbladder. Viscoelastic differences observed between porcine liver and gallbladder tissue suggest that imaging modalities which utilize the mechanical properties of tissue as a primary contrast mechanism can potentially be used to quantitatively differentiate between proximate organs in a clinical setting. These results may facilitate more accurate tissue modeling and add information not currently available to the field of systems characterization and biomedical research. PMID:29373598
ClO radical yields in the reaction of O(1D) with Cl2, HCl, chloromethanes, and chlorofluoromethanes.
Feierabend, Karl J; Papanastasiou, Dimitrios K; Burkholder, James B
2010-11-18
Absolute ClO radical product yields in the gas-phase reactions of O((1)D) with Cl(2), HCl, CCl(4), CHCl(3), CH(2)Cl(2), CH(3)Cl, CFCl(3), CF(2)Cl(2), CF(3)Cl, CHFCl(2), and CHF(2)Cl are reported. Product yields were measured using pulsed-laser photolysis of O(3) to produce O((1)D) in the presence of excess reactant combined with dual wavelength differential cavity ring-down spectroscopic detection of the ClO radical. ClO radical absorption cross sections for the A(2)Π(v = 10) ← X(2)Π(v = 0) transition band head near 280 nm were determined between 200 and 296 K as part of this work. The ClO product yields obtained at room temperature were Cl(2) (0.77 ± 0.10), HCl (0.20 ± 0.04), CCl(4) (0.79 ± 0.04), CHCl(3) (0.77 ± 0.04), CH(2)Cl(2) (0.73 ± 0.04), CH(3)Cl (0.46 ± 0.06), CFCl(3) (0.79 ± 0.04), CF(2)Cl(2) (0.76 ± 0.06), CF(3)Cl (0.82 ± 0.06), CHFCl(2) (0.73 ± 0.05), and CHF(2)Cl (0.56 ± 0.03), where the quoted error limits are 2σ of the measurement precision. ClO product yields in the O((1)D) + Cl(2) and CFCl(3) reactions were found to be independent of temperature between 200 and 296 K, within the precision of the measurements. The absolute ClO yields obtained in this study are compared with previously reported values determined using relative and indirect methods.
Mobashsher, A. T.; Bialkowski, K. S.; Abbosh, A. M.; Crozier, S.
2016-01-01
An intracranial haemorrhage is a life threatening medical emergency, yet only a fraction of the patients receive treatment in time, primarily due to the transport delay in accessing diagnostic equipment in hospitals such as Magnetic Resonance Imaging or Computed Tomography. A mono-static microwave head imaging system that can be carried in an ambulance for the detection and localization of intracranial haemorrhage is presented. The system employs a single ultra-wideband antenna as sensing element to transmit signals in low microwave frequencies towards the head and capture backscattered signals. The compact and low-profile antenna provides stable directional radiation patterns over the operating bandwidth in both near and far-fields. Numerical analysis of the head imaging system with a realistic head model in various situations is performed to realize the scattering mechanism of haemorrhage. A modified delay-and-summation back-projection algorithm, which includes effects of surface waves and a distance-dependent effective permittivity model, is proposed for signal and image post-processing. The efficacy of the automated head imaging system is evaluated using a 3D-printed human head phantom with frequency dispersive dielectric properties including emulated haemorrhages with different sizes located at different depths. Scattered signals are acquired with a compact transceiver in a mono-static circular scanning profile. The reconstructed images demonstrate that the system is capable of detecting haemorrhages as small as 1 cm3. While quantitative analyses reveal that the quality of images gradually degrades with the increase of the haemorrhage’s depth due to the reduction of signal penetration inside the head; rigorous statistical analysis suggests that substantial improvement in image quality can be obtained by increasing the data samples collected around the head. The proposed head imaging prototype along with the processing algorithm demonstrates its feasibility for potential use in ambulances as an effective and low cost diagnostic tool to assure timely triaging of intracranial hemorrhage patients. PMID:27073994
Anticipatory detection of turning in humans for intuitive control of robotic mobility assistance.
Farkhatdinov, Ildar; Roehri, Nicolas; Burdet, Etienne
2017-09-26
Many wearable lower-limb robots for walking assistance have been developed in recent years. However, it remains unclear how they can be commanded in an intuitive and efficient way by their user. In particular, providing robotic assistance to neurologically impaired individuals in turning remains a significant challenge. The control should be safe to the users and their environment, yet yield sufficient performance and enable natural human-machine interaction. Here, we propose using the head and trunk anticipatory behaviour in order to detect the intention to turn in a natural, non-intrusive way, and use it for triggering turning movement in a robot for walking assistance. We therefore study head and trunk orientation during locomotion of healthy adults, and investigate upper body anticipatory behaviour during turning. The collected walking and turning kinematics data are clustered using the k-means algorithm and cross-validation tests and k-nearest neighbours method are used to evaluate the performance of turning detection during locomotion. Tests with seven subjects exhibited accurate turning detection. Head anticipated turning by more than 400-500 ms in average across all subjects. Overall, the proposed method detected turning 300 ms after its initiation and 1230 ms before the turning movement was completed. Using head anticipatory behaviour enabled to detect turning faster by about 100 ms, compared to turning detection using only pelvis orientation measurements. Finally, it was demonstrated that the proposed turning detection can improve the quality of human-robot interaction by improving the control accuracy and transparency.
Massively parallel diffuse optical tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandusky, John V.; Pitts, Todd A.
Diffuse optical tomography systems and methods are described herein. In a general embodiment, the diffuse optical tomography system comprises a plurality of sensor heads, the plurality of sensor heads comprising respective optical emitter systems and respective sensor systems. A sensor head in the plurality of sensors heads is caused to act as an illuminator, such that its optical emitter system transmits a transillumination beam towards a portion of a sample. Other sensor heads in the plurality of sensor heads act as observers, detecting portions of the transillumination beam that radiate from the sample in the fields of view of themore » respective sensory systems of the other sensor heads. Thus, sensor heads in the plurality of sensors heads generate sensor data in parallel.« less
Seo, Kyung Won; Iskenderoglu, Nur Serife; Hwang, Eui Hwan; Chung, Kyu-Rhim; Kim, Seong-Hun
2017-05-01
This article reports C-tube miniplates as a practical temporary anchorage device choice to treat open bite patients with maxillary sinus pneumatization. The C-tube components are titanium anchor plates and monocortical screws that are basically similar to any other miniplate systems, but it has the unique characteristic of the tube head to be malleable. The manipulation of the head part is easy due to the composition of pure titanium. The I-shaped C-tube with 3 holes and T-shaped C-tube miniplates were placed above the apices of maxillary molars as an absolute anchorage system to intrude the posterior maxilla. The bending of the tube heads assisted in reduction of severe open bite patient with maxillary sinus pneumatization. Sinus perforation during placement of skeletal anchorage system weakens stability of the anchorage and further cause complications. Placement of titanium C-tube miniplates allowed reliable skeletal anchorage and avoided maxillary sinus perforation in patients with extreme pneumatizations. Simple bending of C-tube miniplates ensured increased orthodontic intrusion force without having to replace them, and eliminated consequences such as perforation of maxillary sinus, sinusitis, soft tissue irritation, or infection. Anatomic difficulties in the placement of temporary anchorage device can be easily managed by using the bendable C-tube miniplate. It can serve as a great alternative over miniscrews or regular miniplates with reduced risk of sinus perforation and ability to bend the head portion to control orthodontic vectors and forces.
NASA Astrophysics Data System (ADS)
Chen, Hai-Wen; McGurr, Mike
2016-05-01
We have developed a new way for detection and tracking of human full-body and body-parts with color (intensity) patch morphological segmentation and adaptive thresholding for security surveillance cameras. An adaptive threshold scheme has been developed for dealing with body size changes, illumination condition changes, and cross camera parameter changes. Tests with the PETS 2009 and 2014 datasets show that we can obtain high probability of detection and low probability of false alarm for full-body. Test results indicate that our human full-body detection method can considerably outperform the current state-of-the-art methods in both detection performance and computational complexity. Furthermore, in this paper, we have developed several methods using color features for detection and tracking of human body-parts (arms, legs, torso, and head, etc.). For example, we have developed a human skin color sub-patch segmentation algorithm by first conducting a RGB to YIQ transformation and then applying a Subtractive I/Q image Fusion with morphological operations. With this method, we can reliably detect and track human skin color related body-parts such as face, neck, arms, and legs. Reliable body-parts (e.g. head) detection allows us to continuously track the individual person even in the case that multiple closely spaced persons are merged. Accordingly, we have developed a new algorithm to split a merged detection blob back to individual detections based on the detected head positions. Detected body-parts also allow us to extract important local constellation features of the body-parts positions and angles related to the full-body. These features are useful for human walking gait pattern recognition and human pose (e.g. standing or falling down) estimation for potential abnormal behavior and accidental event detection, as evidenced with our experimental tests. Furthermore, based on the reliable head (face) tacking, we have applied a super-resolution algorithm to enhance the face resolution for improved human face recognition performance.
Improving Cancer Detection and Dose Efficiency in Dedicated Breast Cancer CT
2011-02-01
17. A. E. Burgess, F. L. Jacobson, and P. F. Judy , “ Human observer detection experiments with mammograms and power-law noise,” Med. Phys., Vol. 28...Jacobson F L and Judy P F 2001 Human observer detection experiments with mammograms and power-law noise Med. Phys. 28 419–37 Crawford C R and Kak A C 1979...anthropomorphic head phantom was designed for realistically simulating human head [12], it features not only a natural human skeleton but also contrast
Estimation of sleep status in sleep apnea patients using a novel head actigraphy technique.
Hummel, Richard; Bradley, T Douglas; Fernie, Geoff R; Chang, S J Isaac; Alshaer, Hisham
2015-01-01
Polysomnography is a comprehensive modality for diagnosing sleep apnea (SA), but it is expensive and not widely available. Several technologies have been developed for portable diagnosis of SA in the home, most of which lack the ability to detect sleep status. Wrist actigraphy (accelerometry) has been adopted to cover this limitation. However, head actigraphy has not been systematically evaluated for this purpose. Therefore, the aim of this study was to evaluate the ability of head actigraphy to detect sleep/wake status. We obtained full overnight 3-axis head accelerometry data from 75 sleep apnea patient recordings. These were split into training and validation groups (2:1). Data were preprocessed and 5 features were extracted. Different feature combinations were fed into 3 different classifiers, namely support vector machine, logistic regression, and random forests, each of which was trained and validated on a different subgroup. The random forest algorithm yielded the highest performance, with an area under the receiver operating characteristic (ROC) curve of 0.81 for detection of sleep status. This shows that this technique has a very good performance in detecting sleep status in SA patients despite the specificities in this population, such as respiration related movements.
Electromagnetic Detection of Fatigue Cracks under Protruding Head Ferromagnetic Fasteners
NASA Technical Reports Server (NTRS)
Wincheski, Buzz; Namkung, Min
2004-01-01
The detection of fatigue cracks under installed fasteners has been a major goal of the aging aircraft NDE community. The Sliding Probe, Magneto-Optic Imager, Rotating Self-Nulling Probe, Low Frequency Eddy Current Array, and Eddyscan systems are among the instruments developed for this inspection. It has been verified that the detection of fatigue cracks under flush head aluminum and titanium fasteners can be accomplished with a high resolution by the above techniques. The detection of fatigue cracks under ferromagnetic and protruding head fasteners, however, has been found to be much more difficult. For the present work, the inspection for fatigue cracks under SAE 4340 Steel Hi-Lok fasteners is explored. Modifications to the Rotating Self-Nulling Eddy Current Probe System are presented which enable the detection of fatigue cracks hidden under the protruding head of the ferromagnetic fastener. Inspection results for samples with varying length EDM notches are shown, as well as a comparison between the signature from an EDM notch and an actual fatigue crack. Finite Element Modeling is used to investigate the effect of the ferromagnetic fastener on the induced eddy current distribution in order to help explain the detection characteristics of the system. This paper will also introduce a modification to the Rotating Probe System designed specifically for the detection of deeply buried flaws in multilayer conductors. The design change incorporates a giant magnetoresistive (GMR) sensor as the pickup device to improve the low frequency performance of the probe. The flaw detection capabilities of the GMR based Self- Nulling Probe are presented along with the status of the GMR based Rotating Probe System for detection of deeply buried flaws under installed fasteners.
Jiang, Hao; Titsch, Craig; Zeng, Jianing; Jones, Barry; Joyce, Philip; Gandhi, Yash; Turley, Wesley; Burrell, Richard; Aubry, Anne F; Arnold, Mark E
2017-09-05
The oral absolute bioavailability of beclabuvir in healthy subjects was determined using a microdose (100μg) of the stable isotopically labeled tracer via intravenous (IV) infusion started after oral dosing of beclabuvir (150mg). To simultaneously analyze the concentrations of the IV microtracer ([ 13 C 6 ]beclabuvir) and beclabuvir in plasma samples, a liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) method was initially developed. Surprisingly beclabuvir significantly interfered with the IV microtracer detection when using the selected reaction monitoring (SRM) in the assay. An interfering component from the drug substance was observed using a high resolution mass spectrometer (HRMS). The mass-to-charge (m/z) of the interfering component was -32ppm different from the nominal value for the IV microtracer and thus could not be differentiated in the SRM assay by the unit mass resolution. To overcome this interference, we evaluated two approaches by either monitoring an alternative product ion using the SRM assay or isolating the interfering component using the parallel reaction monitoring (PRM) assay on the HRMS. This case study has demonstrated two practical approaches for overcoming interferences with the detection of stable isotopically labeled IV microtracers in the evaluation of absolute bioavailability, which provides users the flexibility in using either LC-MS/MS or HRMS to mitigate unpredicted interferences in the assay to support microtracer absolute bioavailability studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Kevin T; Izquierdo-Garcia, David; Poynton, Clare B; Chonde, Daniel B; Catana, Ciprian
2017-03-01
To propose an MR-based method for generating continuous-valued head attenuation maps and to assess its accuracy and reproducibility. Demonstrating that novel MR-based photon attenuation correction methods are both accurate and reproducible is essential prior to using them routinely in research and clinical studies on integrated PET/MR scanners. Continuous-valued linear attenuation coefficient maps ("μ-maps") were generated by combining atlases that provided the prior probability of voxel positions belonging to a certain tissue class (air, soft tissue, or bone) and an MR intensity-based likelihood classifier to produce posterior probability maps of tissue classes. These probabilities were used as weights to generate the μ-maps. The accuracy of this probabilistic atlas-based continuous-valued μ-map ("PAC-map") generation method was assessed by calculating the voxel-wise absolute relative change (RC) between the MR-based and scaled CT-based attenuation-corrected PET images. To assess reproducibility, we performed pair-wise comparisons of the RC values obtained from the PET images reconstructed using the μ-maps generated from the data acquired at three time points. The proposed method produced continuous-valued μ-maps that qualitatively reflected the variable anatomy in patients with brain tumor and agreed well with the scaled CT-based μ-maps. The absolute RC comparing the resulting PET volumes was 1.76 ± 2.33 %, quantitatively demonstrating that the method is accurate. Additionally, we also showed that the method is highly reproducible, the mean RC value for the PET images reconstructed using the μ-maps obtained at the three visits being 0.65 ± 0.95 %. Accurate and highly reproducible continuous-valued head μ-maps can be generated from MR data using a probabilistic atlas-based approach.
Wiesinger, Florian; Bylund, Mikael; Yang, Jaewon; Kaushik, Sandeep; Shanbhag, Dattesh; Ahn, Sangtae; Jonsson, Joakim H; Lundman, Josef A; Hope, Thomas; Nyholm, Tufve; Larson, Peder; Cozzini, Cristina
2018-02-18
To describe a method for converting Zero TE (ZTE) MR images into X-ray attenuation information in the form of pseudo-CT images and demonstrate its performance for (1) attenuation correction (AC) in PET/MR and (2) dose planning in MR-guided radiation therapy planning (RTP). Proton density-weighted ZTE images were acquired as input for MR-based pseudo-CT conversion, providing (1) efficient capture of short-lived bone signals, (2) flat soft-tissue contrast, and (3) fast and robust 3D MR imaging. After bias correction and normalization, the images were segmented into bone, soft-tissue, and air by means of thresholding and morphological refinements. Fixed Hounsfield replacement values were assigned for air (-1000 HU) and soft-tissue (+42 HU), whereas continuous linear mapping was used for bone. The obtained ZTE-derived pseudo-CT images accurately resembled the true CT images (i.e., Dice coefficient for bone overlap of 0.73 ± 0.08 and mean absolute error of 123 ± 25 HU evaluated over the whole head, including errors from residual registration mismatches in the neck and mouth regions). The linear bone mapping accounted for bone density variations. Averaged across five patients, ZTE-based AC demonstrated a PET error of -0.04 ± 1.68% relative to CT-based AC. Similarly, for RTP assessed in eight patients, the absolute dose difference over the target volume was found to be 0.23 ± 0.42%. The described method enables MR to pseudo-CT image conversion for the head in an accurate, robust, and fast manner without relying on anatomical prior knowledge. Potential applications include PET/MR-AC, and MR-guided RTP. © 2018 International Society for Magnetic Resonance in Medicine.
Sheets, Rodney A.; Bair, E. Scott; Rowe, Gary L.
1998-01-01
Combined use of the tritium/helium 3 (3H/3He) dating technique and particle-tracking analysis can improve flow-model calibration. As shown at two sites in the Great Miami buried-valley aquifer in southwestern Ohio, the combined use of 3H/3He age dating and particle tracking led to a lower mean absolute error between measured heads and simulated heads than in the original calibrated models and/or between simulated travel times and 3H/3He ages. Apparent groundwater ages were obtained for water samples collected from 44 wells at two locations where previously constructed finite difference models of groundwater flow were available (Mound Plant and Wright-Patterson Air Force Base (WPAFB)). The two-layer Mound Plant model covers 11 km2 within the buried-valley aquifer. The WPAFB model has three layers and covers 262 km2 within the buried-valley aquifer and adjacent bedrock uplands. Sampled wells were chosen along flow paths determined from potentiometric maps or particle-tracking analyses. Water samples were collected at various depths within the aquifer. In the Mound Plant area, samples used for comparison of 3H/3He ages with simulated travel times were from wells completed in the uppermost model layer. Simulated travel times agreed well with 3H/3He ages. The mean absolute error (MAE) was 3.5 years. Agreement in ages at WPAFB decreased with increasing depth in the system. The MAEs were 1.63, 17.2, and 255 years for model layers 1, 2, and 3, respectively. Discrepancies between the simulated travel times and 3H/3He ages were assumed to be due to improper conceptualization or incorrect parameterization of the flow models. Selected conceptual and parameter modifications to the models resulted in improved agreement between 3H/3He ages and simulated travel times and between measured and simulated heads and flows.
Costas loop lock detection in the advanced receiver
NASA Technical Reports Server (NTRS)
Mileant, A.; Hinedi, S.
1989-01-01
The advanced receiver currently being developed uses a Costas digital loop to demodulate the subcarrier. Previous analyses of lock detector algorithms for Costas loops have ignored the effects of the inherent correlation between the samples of the phase-error process. Accounting for this correlation is necessary to achieve the desired lock-detection probability for a given false-alarm rate. Both analysis and simulations are used to quantify the effects of phase correlation on lock detection for the square-law and the absolute-value type detectors. Results are obtained which depict the lock-detection probability as a function of loop signal-to-noise ratio for a given false-alarm rate. The mathematical model and computer simulation show that the square-law detector experiences less degradation due to phase jitter than the absolute-value detector and that the degradation in detector signal-to-noise ratio is more pronounced for square-wave than for sine-wave signals.
NASA Astrophysics Data System (ADS)
Selb, Juliette; Ogden, Tyler M.; Dubb, Jay; Fang, Qianqian; Boas, David A.
2013-03-01
Time-domain near-infrared spectroscopy (TD-NIRS) offers the ability to measure the absolute baseline optical properties of a tissue. Specifically, for brain imaging, the robust assessment of cerebral blood volume and oxygenation based on measurement of cerebral hemoglobin concentrations is essential for reliable cross-sectional and longitudinal studies. In adult heads, these baseline measurements are complicated by the presence of thick extra-cerebral tissue (scalp, skull, CSF). A simple semi-infinite homogeneous model of the head has proven to have limited use because of the large errors it introduces in the recovered brain absorption. Analytical solutions for layered media have shown improved performance on Monte-Carlo simulated data and layered phantom experiments, but their validity on real adult head data has never been demonstrated. With the advance of fast Monte Carlo approaches based on GPU computation, numerical methods to solve the radiative transfer equation become viable alternatives to analytical solutions of the diffusion equation. Monte Carlo approaches provide the additional advantage to be adaptable to any geometry, in particular more realistic head models. The goals of the present study were twofold: (1) to implement a fast and flexible Monte Carlo-based fitting routine to retrieve the brain optical properties; (2) to characterize the performances of this fitting method on realistic adult head data. We generated time-resolved data at various locations over the head, and fitted them with different models of light propagation: the homogeneous analytical model, and Monte Carlo simulations for three head models: a two-layer slab, the true subject's anatomy, and that of a generic atlas head. We found that the homogeneous model introduced a median 20 to 25% error on the recovered brain absorption, with large variations over the range of true optical properties. The two-layer slab model only improved moderately the results over the homogeneous one. On the other hand, using a generic atlas head registered to the subject's head surface decreased the error by a factor of 2. When the information is available, using the true subject anatomy offers the best performance.
Position detectors, methods of detecting position, and methods of providing positional detectors
Weinberg, David M.; Harding, L. Dean; Larsen, Eric D.
2002-01-01
Position detectors, welding system position detectors, methods of detecting various positions, and methods of providing position detectors are described. In one embodiment, a welding system positional detector includes a base that is configured to engage and be moved along a curved surface of a welding work piece. At least one position detection apparatus is provided and is connected with the base and configured to measure angular position of the detector relative to a reference vector. In another embodiment, a welding system positional detector includes a weld head and at least one inclinometer mounted on the weld head. The one inclinometer is configured to develop positional data relative to a reference vector and the position of the weld head on a non-planar weldable work piece.
Fetal head detection and measurement in ultrasound images by an iterative randomized Hough transform
NASA Astrophysics Data System (ADS)
Lu, Wei; Tan, Jinglu; Floyd, Randall C.
2004-05-01
This paper describes an automatic method for measuring the biparietal diameter (BPD) and head circumference (HC) in ultrasound fetal images. A total of 217 ultrasound images were segmented by using a K-Mean classifier, and the head skull was detected in 214 of the 217 cases by an iterative randomized Hough transform developed for detection of incomplete curves in images with strong noise without user intervention. The automatic measurements were compared with conventional manual measurements by sonographers and a trained panel. The inter-run variations and differences between the automatic and conventional measurements were small compared with published inter-observer variations. The results showed that the automated measurements were as reliable as the expert measurements and more consistent. This method has great potential in clinical applications.
Towers, John; Burgess-Limerick, Robin; Riek, Stephan
2014-12-01
The aim of this study was to enable the head-up monitoring of two interrelated aircraft navigation instruments by developing a 3-D auditory display that encodes this navigation information within two spatially discrete sonifications. Head-up monitoring of aircraft navigation information utilizing 3-D audio displays, particularly involving concurrently presented sonifications, requires additional research. A flight simulator's head-down waypoint bearing and course deviation instrument readouts were conveyed to participants via a 3-D auditory display. Both readouts were separately represented by a colocated pair of continuous sounds, one fixed and the other varying in pitch, which together encoded the instrument value's deviation from the norm. Each sound pair's position in the listening space indicated the left/right parameter of its instrument's readout. Participants' accuracy in navigating a predetermined flight plan was evaluated while performing a head-up task involving the detection of visual flares in the out-of-cockpit scene. The auditory display significantly improved aircraft heading and course deviation accuracy, head-up time, and flare detections. Head tracking did not improve performance by providing participants with the ability to orient potentially conflicting sounds, suggesting that the use of integrated localizing cues was successful. Conclusion: A supplementary 3-D auditory display enabled effective head-up monitoring of interrelated navigation information normally attended to through a head-down display. Pilots operating aircraft, such as helicopters and unmanned aerial vehicles, may benefit from a supplementary auditory display because they navigate in two dimensions while performing head-up, out-of-aircraft, visual tasks.
Deurvorst, S E; Hoekstra, O S; Castelijns, J A; Witte, B I; Leemans, C R; de Bree, R
2018-06-01
The detection of distant metastases is of major importance in management of head and neck squamous cell carcinoma patients. All patients underwent 18 FDG PET/CT for the detection of distant metastases. Retrospective single-centre study. Head and neck squamous cell carcinoma patients with high-risk factors for distant metastases. Accuracy of 18 FDG PET/CT for the detection of distant metastases using clinical development of distant metastases and a minimal follow-up of twelve months as reference standard. Comparison of overall survival between patients diagnosed with distant metastases during initial screening and patients diagnosed with distant metastases during follow-up. In 23 (12%) of the 190 patients, 18 FDG PET/CT detected distant metastases at screening. Sensitivity and negative predictive value were 46.2% (95% CI 32.6-59.7) and 82.6% (95% CI 76.8-88.5). No difference in median overall survival from the time of distant metastases detection was found between patients diagnosed with DM during work-up or during follow-up. In head and neck squamous cell carcinoma patients with high-risk factors, 18 FDG PET/CT has a high negative predictive value for the detection of distant metastases and should be used in daily clinical practice, although the sensitivity is limited when long-term follow-up is used as reference standard. © 2018 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.
Laser Truss Sensor for Segmented Telescope Phasing
NASA Technical Reports Server (NTRS)
Liu, Duncan T.; Lay, Oliver P.; Azizi, Alireza; Erlig, Herman; Dorsky, Leonard I.; Asbury, Cheryl G.; Zhao, Feng
2011-01-01
A paper describes the laser truss sensor (LTS) for detecting piston motion between two adjacent telescope segment edges. LTS is formed by two point-to-point laser metrology gauges in a crossed geometry. A high-resolution (<30 nm) LTS can be implemented with existing laser metrology gauges. The distance change between the reference plane and the target plane is measured as a function of the phase change between the reference and target beams. To ease the bandwidth requirements for phase detection electronics (or phase meter), homodyne or heterodyne detection techniques have been used. The phase of the target beam also changes with the refractive index of air, which changes with the air pressure, temperature, and humidity. This error can be minimized by enclosing the metrology beams in baffles. For longer-term (weeks) tracking at the micron level accuracy, the same gauge can be operated in the absolute metrology mode with an accuracy of microns; to implement absolute metrology, two laser frequencies will be used on the same gauge. Absolute metrology using heterodyne laser gauges is a demonstrated technology. Complexity of laser source fiber distribution can be optimized using the range-gated metrology (RGM) approach.
Rapid, absolute calibration of x-ray filters employed by laser-produced plasma diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, G. V.; Beiersdorfer, P.; Emig, J.
2008-10-15
The Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory is being used to absolutely calibrate the transmission efficiency of x-ray filters employed by diodes and spectrometers used to diagnose laser-produced plasmas. EBIT emits strong, discrete monoenergetic lines at appropriately chosen x-ray energies. X rays are detected using the high resolution EBIT Calorimeter Spectrometer (ECS), developed for LLNL at the NASA/Goddard Space Flight Center. X-ray filter transmission efficiency is determined by dividing the x-ray counts detected when the filter is in the line of sight by those detected when out of the line of sight. Verification ofmore » filter thickness can be completed in only a few hours, and absolute efficiencies can be calibrated in a single day over a broad range from about 0.1 to 15 keV. The EBIT calibration lab has been used to field diagnostics (e.g., the OZSPEC instrument) with fully calibrated x-ray filters at the OMEGA laser. Extensions to use the capability for calibrating filter transmission for the DANTE instrument on the National Ignition Facility are discussed.« less
John, Grace C.; Nduati, Ruth W.; Mbori-Ngacha, Dorothy; Overbaugh, Julie; Welch, Mary; Richardson, Barbra A.; Ndinya-Achola, Jeckoniah; Bwayo, Job; Krieger, John; Onyango, Francis; Kreiss, Joan K.
2012-01-01
The presence of human immunodeficiency virus type 1 (HIV-1) in genital secretions may be a determinant of vertical HIV-1 transmission. Cervical and vaginal secretions from HIV-1–seropositive pregnant women were evaluated to determine prevalence and correlates of HIV-1–infected cells in the genital tract. HIV-1 DNA was detected by polymerase chain reaction in 32% of 212 cervical and 10% of 215 vaginal specimens. Presence of HIV-1 DNA in the cervix was associated with cervical mucopus and a significantly lower absolute CD4 cell count (354 vs. 469, P < .001). An absolute CD4 cell count <200 was associated with a 9.6-fold increased odds of cervical HIV-1 DNA detection compared with a count ≥500 (95% confidence interval, 2.8–34.2). Detection of vaginal HIV-1 DNA was associated with abnormal vaginal discharge, lower absolute CD4 cell count, and severe vitamin A deficiency. Presence of HIV-1–infected cells in genital secretions was associated with immunosuppression and abnormal cervical or vaginal discharge. PMID:8985196
Brain stem omnipause neurons and the control of combined eye-head gaze saccades in the alert cat.
Paré, M; Guitton, D
1998-06-01
When the head is unrestrained, rapid displacements of the visual axis-gaze shifts (eye-re-space)-are made by coordinated movements of the eyes (eye-re-head) and head (head-re-space). To address the problem of the neural control of gaze shifts, we studied and contrasted the discharges of omnipause neurons (OPNs) during a variety of combined eye-head gaze shifts and head-fixed eye saccades executed by alert cats. OPNs discharged tonically during intersaccadic intervals and at a reduced level during slow perisaccadic gaze movements sometimes accompanying saccades. Their activity ceased for the duration of the saccadic gaze shifts the animal executed, either by head-fixed eye saccades alone or by combined eye-head movements. This was true for all types of gaze shifts studied: active movements to visual targets; passive movements induced by whole-body rotation or by head rotation about stationary body; and electrically evoked movements by stimulation of the caudal part of the superior colliculus (SC), a central structure for gaze control. For combined eye-head gaze shifts, the OPN pause was therefore not correlated to the eye-in-head trajectory. For instance, in active gaze movements, the end of the pause was better correlated with the gaze end than with either the eye saccade end or the time of eye counterrotation. The hypothesis that cat OPNs participate in controlling gaze shifts is supported by these results, and also by the observation that the movements of both the eyes and the head were transiently interrupted by stimulation of OPNs during gaze shifts. However, we found that the OPN pause could be dissociated from the gaze-motor-error signal producing the gaze shift. First, OPNs resumed discharging when perturbation of head motion briefly interrupted a gaze shift before its intended amplitude was attained. Second, stimulation of caudal SC sites in head-free cat elicited large head-free gaze shifts consistent with the creation of a large gaze-motor-error signal. However, stimulation of the same sites in head-fixed cat produced small "goal-directed" eye saccades, and OPNs paused only for the duration of the latter; neither a pause nor an eye movement occurred when the same stimulation was applied with the eyes at the goal location. We conclude that OPNs can be controlled by neither a simple eye control system nor an absolute gaze control system. Our data cannot be accounted for by existing models describing the control of combined eye-head gaze shifts and therefore put new constraints on future models, which will have to incorporate all the various signals that act synergistically to control gaze shifts.
Texting and Walking: Strategies for Postural Control and Implications for Safety
Schabrun, Siobhan M.; van den Hoorn, Wolbert; Moorcroft, Alison; Greenland, Cameron; Hodges, Paul W.
2014-01-01
There are concerns about the safety of texting while walking. Although evidence of negative effects of mobile phone use on gait is scarce, cognitive distraction, altered mechanical demands, and the reduced visual field associated with texting are likely to have an impact. In 26 healthy individuals we examined the effect of mobile phone use on gait. Individuals walked at a comfortable pace in a straight line over a distance of ∼8.5 m while; 1) walking without the use of a phone, 2) reading text on a mobile phone, or 3) typing text on a mobile phone. Gait performance was evaluated using a three-dimensional movement analysis system. In comparison with normal waking, when participants read or wrote text messages they walked with: greater absolute lateral foot position from one stride to the next; slower speed; greater rotation range of motion (ROM) of the head with respect to global space; the head held in a flexed position; more in-phase motion of the thorax and head in all planes, less motion between thorax and head (neck ROM); and more tightly organized coordination in lateral flexion and rotation directions. While writing text, participants walked slower, deviated more from a straight line and used less neck ROM than reading text. Although the arms and head moved with the thorax to reduce relative motion of the phone and facilitate reading and texting, movement of the head in global space increased and this could negatively impact the balance system. Texting, and to a lesser extent reading, modify gait performance. Texting or reading on a mobile phone may pose an additional risk to safety for pedestrians navigating obstacles or crossing the road. PMID:24465402
NASA Astrophysics Data System (ADS)
Lippman, Thomas; Brockie, Richard; Coker, Jon; Contreras, John; Galbraith, Rick; Garzon, Samir; Hanson, Weldon; Leong, Tom; Marley, Arley; Wood, Roger; Zakai, Rehan; Zolla, Howard; Duquette, Paul; Petrizzi, Joe
2015-05-01
Exponential growth of the areal density has driven the magnetic recording industry for almost sixty years. But now areal density growth is slowing down, suggesting that current technologies are reaching their fundamental limit. The next generation of recording technologies, namely, energy-assisted writing and bit-patterned media, remains just over the horizon. Two-Dimensional Magnetic Recording (TDMR) is a promising new approach, enabling continued areal density growth with only modest changes to the heads and recording electronics. We demonstrate a first generation implementation of TDMR by using a dual-element read sensor to improve the recovery of data encoded by a conventional low-density parity-check (LDPC) channel. The signals are combined with a 2D equalizer into a single modified waveform that is decoded by a standard LDPC channel. Our detection hardware can perform simultaneous measurement of the pre- and post-combined error rate information, allowing one set of measurements to assess the absolute areal density capability of the TDMR system as well as the gain over a conventional shingled magnetic recording system with identical components. We discuss areal density measurements using this hardware and demonstrate gains exceeding five percent based on experimental dual reader components.
Trested, D.G.; Chan, Matthew D.; Bridges, W.C.; Isely, J.J.
2011-01-01
Long-term restoration efforts for lake sturgeon Acipenser fulvescens populations will benefit from better understanding of this species' movements and habitat use in riverine systems. Radio transmitters were implanted in both juvenile and adult lake sturgeon in the Grasse River, New York, and individuals were relocated over a 2-year period. Adult lake sturgeon demonstrated greater minimum daily distance moved, absolute distance moved, and mean home range size than juvenile lake sturgeon during the spring. During the course of the study, both adult and juvenile lake sturgeon exhibited movements upstream and downstream through a breached low-head weir, and individuals did not necessarily remain resident on an annual basis in the Grasse River. Mesohabitat and substrate use patterns were determined based on comparisons of frequency distributions for relocated lake sturgeon and quantified mesohabitat and substrate over a 15-km river reach. Lake sturgeon used pool mesohabitat and limited their use of run mesohabitat under both low- and mid-flow conditions. During most of the year, adult and juvenile lake sturgeon were detected over silt substrate. This study illustrates behavioral differences and similarities between the movements and habitat use of adult and juvenile lake sturgeon in a riverine system.
Autoantibody Approach for Serum-Based Detection of Head and Neck Cancer — EDRN Public Portal
Our long term goal is to improve survival of patients with head and neck squamous cell carcinoma (HNSCC) through early detection using simple noninvasive serum assays in an ELISA-like platform. The objective of this proposal is to improve and confirm the validity of a diagnostic serum assay based on a panel of cancer-specific biomarkers for early cancer detection in patients with HNSCC. Our central hypothesis is that the detection of antibody responses to HNSCC-specific antigens, using a panel of biomarkers, can provide sufficient sensitivity and specificity suitable for clinical testing in the primary setting to screen and diagnose HNSCC in high risk populations to improve early detection.
Standardization approaches in absolute quantitative proteomics with mass spectrometry.
Calderón-Celis, Francisco; Encinar, Jorge Ruiz; Sanz-Medel, Alfredo
2017-07-31
Mass spectrometry-based approaches have enabled important breakthroughs in quantitative proteomics in the last decades. This development is reflected in the better quantitative assessment of protein levels as well as to understand post-translational modifications and protein complexes and networks. Nowadays, the focus of quantitative proteomics shifted from the relative determination of proteins (ie, differential expression between two or more cellular states) to absolute quantity determination, required for a more-thorough characterization of biological models and comprehension of the proteome dynamism, as well as for the search and validation of novel protein biomarkers. However, the physico-chemical environment of the analyte species affects strongly the ionization efficiency in most mass spectrometry (MS) types, which thereby require the use of specially designed standardization approaches to provide absolute quantifications. Most common of such approaches nowadays include (i) the use of stable isotope-labeled peptide standards, isotopologues to the target proteotypic peptides expected after tryptic digestion of the target protein; (ii) use of stable isotope-labeled protein standards to compensate for sample preparation, sample loss, and proteolysis steps; (iii) isobaric reagents, which after fragmentation in the MS/MS analysis provide a final detectable mass shift, can be used to tag both analyte and standard samples; (iv) label-free approaches in which the absolute quantitative data are not obtained through the use of any kind of labeling, but from computational normalization of the raw data and adequate standards; (v) elemental mass spectrometry-based workflows able to provide directly absolute quantification of peptides/proteins that contain an ICP-detectable element. A critical insight from the Analytical Chemistry perspective of the different standardization approaches and their combinations used so far for absolute quantitative MS-based (molecular and elemental) proteomics is provided in this review. © 2017 Wiley Periodicals, Inc.
Effects of head tilt on visual field testing with a head-mounted perimeter imo
Matsumoto, Chota; Nomoto, Hiroki; Numata, Takuya; Eura, Mariko; Yamashita, Marika; Hashimoto, Shigeki; Okuyama, Sachiko; Kimura, Shinji; Yamanaka, Kenzo; Chiba, Yasutaka; Aihara, Makoto; Shimomura, Yoshikazu
2017-01-01
Purpose A newly developed head-mounted perimeter termed “imo” enables visual field (VF) testing without a fixed head position. Because the positional relationship between the subject’s head and the imo is fixed, the effects of head position changes on the test results are small compared with those obtained using a stationary perimeter. However, only ocular counter-roll (OCR) induced by head tilt might affect VF testing. To quantitatively reveal the effects of head tilt and OCR on the VF test results, we investigated the associations among the head-tilt angle, OCR amplitude and VF testing results. Subjects and methods For 20 healthy subjects, we binocularly recorded static OCR (s-OCR) while tilting the subject’s head at an arbitrary angle ranging from 0° to 60° rightward or leftward in 10° increments. By monitoring iris patterns, we evaluated the s-OCR amplitude. We also performed blind spot detection while tilting the subject’s head by an arbitrary angle ranging from 0° to 50° rightward or leftward in 10° increments to calculate the angle by which the blind spot rotates because of head tilt. Results The association between s-OCR amplitude and head-tilt angle showed a sinusoidal relationship. In blind spot detection, the blind spot rotated to the opposite direction of the head tilt, and the association between the rotation angle of the blind spot and the head-tilt angle also showed a sinusoidal relationship. The rotation angle of the blind spot was strongly correlated with the s-OCR amplitude (R2≥0.94, p<0.0001). A head tilt greater than 20° with imo causes interference between adjacent test areas. Conclusions Both the s-OCR amplitude and the rotation angle of the blind spot were correlated with the head-tilt angle by sinusoidal regression. The rotated VF was correlated with the s-OCR amplitude. During perimetry using imo, the change in the subject’s head tilt should be limited to 20°. PMID:28945777
Kirsch, L E; Nguyen, L; Moeckly, C S
1997-01-01
The development of mass spectrometry-based leak detection for pharmaceutical container integrity was undertaken to provide an alternative to microbial challenge testing. Standard 10-mL vials were modified to contain pinholes (0.5 to 10 microns) by affixing micropipettes with epoxy into 2-mm vial side wall holes. The absolute leak rate was determined using vials that were sealed in a tracer (helium) environment with butyl rubber stoppers and crimps. Alternatively leak rates were determined using vials that were sealed in room air and exposed to tracer under pressure (charging or bombing). Tracer leak rates were measured with mass spectrometry leak rate detectors. The absolute leak rate was correlated the squared nominal leak radius which suggested that the mode of gas flow through the glass pipette leaks was more turbulent than viscous even at low leak rates typically associated with viscous flow. The minimum observed absolute leak rate was about 10(-6.6) std cc/sec and was likely due to helium permeation through the rubber stoppers. Heat-stressed rubber stoppers did not affect the baseline absolute leak rate. Adsorption of helium tracer to the test unit surfaces was found to confound baseline leak rate measurement reliability but was eliminated as a source of variation by exposing the test units to ambient air for > or = 12 hours. The absolute leak rate and the leak rate measured after charging were related in a mathematically predictable way.
Conebeam CT of the head and neck, part 1: physical principles.
Miracle, A C; Mukherji, S K
2009-06-01
Conebeam x-ray CT (CBCT) is a developing imaging technique designed to provide relatively low-dose high-spatial-resolution visualization of high-contrast structures in the head and neck and other anatomic areas. This first installment in a 2-part review will address the physical principles underlying CBCT imaging as it is used in dedicated head and neck scanners. Concepts related to CBCT acquisition geometry, flat panel detection, and image quality will be explored in detail. Particular emphasis will be placed on technical limitations to low-contrast detectability and radiation dose. Proposed methods of x-ray scatter reduction will also be discussed.
Fiedler, Klaus; Kareev, Yaakov; Avrahami, Judith; Beier, Susanne; Kutzner, Florian; Hütter, Mandy
2016-01-01
Detecting changes, in performance, sales, markets, risks, social relations, or public opinions, constitutes an important adaptive function. In a sequential paradigm devised to investigate detection of change, every trial provides a sample of binary outcomes (e.g., correct vs. incorrect student responses). Participants have to decide whether the proportion of a focal feature (e.g., correct responses) in the population from which the sample is drawn has decreased, remained constant, or increased. Strong and persistent anomalies in change detection arise when changes in proportional quantities vary orthogonally to changes in absolute sample size. Proportional increases are readily detected and nonchanges are erroneously perceived as increases when absolute sample size increases. Conversely, decreasing sample size facilitates the correct detection of proportional decreases and the erroneous perception of nonchanges as decreases. These anomalies are however confined to experienced samples of elementary raw events from which proportions have to be inferred inductively. They disappear when sample proportions are described as percentages in a normalized probability format. To explain these challenging findings, it is essential to understand the inductive-learning constraints imposed on decisions from experience.
Electromagnetic waves with frequencies near the local proton gyrofrequency: ISEE-3 1 AU observations
NASA Technical Reports Server (NTRS)
Tsurutani, Bruce T.; Arballo, John K.; Mok, John; Smith, Edward J.; Mason, Glenn M.; Tan, Lun C.
1994-01-01
Low Frequency (LF) electromagnetic waves with periods near the local proton gyrofrequency have been detected in interplanetary space by the magnetometer onboard International-Sun-Earth-Explorer-3 (ISEE-3). Transverse peak-to-peak amplitudes as large as delta vector B/absolute value of B approximately 0.4 have been noted with compressional components (Delta absolute value of B/absolute value of B) typically less than or = 0.1. Generally, the waves have even smaller amplitudes, or are not detectable within the solar wind turbulence. The waves are elliptically/linearly polarized and are often, but not always, found to propagate nearly along vector B(sub zero). Both right- and left-hand polarizations in the spacecraft-frame have been detected. The waves are observed during all orientations of the interplanetary magnetic field, with the Parker spiral orientation being the most common case. Because the waves are detected at and near the local proton cyclotron frequency, the generation mechanism must almost certainly be solar wind pickup of freshly created hydrogen ions. Possible sources for the hydrogen are the Earth's atmosphere, coronal mass ejections from the Sun, comets and interstellar neutral atoms. At this time it is not obvious which potential source is the correct one. Statistical tests employing over one year of ISEE-3 data will be done in the near future to eliminate/confirm some of these possibilities.
Sentinel Node Detection in Head and Neck Malignancies: Innovations in Radioguided Surgery
Vermeeren, L.; Klop, W. M. C.; van den Brekel, M. W. M.; Balm, A. J. M.; Nieweg, O. E.; Valdés Olmos, R. A.
2009-01-01
Sentinel node mapping is becoming a routine procedure for staging of various malignancies, because it can determine lymph node status more precisely. Due to anatomical problems, localizing sentinel nodes in the head and neck region on the basis of conventional images can be difficult. New diagnostic tools can provide better visualization of sentinel nodes. In an attempt to keep up with possible scientific progress, this article reviews new and innovative tools for sentinel node localization in this specific area. The overview comprises a short introduction of the sentinel node procedure as well as indications in the head and neck region. Then the results of SPECT/CT for sentinel node detection are described. Finally, a portable gamma camera to enable intraoperative real-time imaging with improved sentinel node detection is described. PMID:20016804
Verikas, Antanas; Vaiciukynas, Evaldas; Gelzinis, Adas; Parker, James; Olsson, M Charlotte
2016-04-23
This study analyzes muscle activity, recorded in an eight-channel electromyographic (EMG) signal stream, during the golf swing using a 7-iron club and exploits information extracted from EMG dynamics to predict the success of the resulting shot. Muscles of the arm and shoulder on both the left and right sides, namely flexor carpi radialis, extensor digitorum communis, rhomboideus and trapezius, are considered for 15 golf players (∼5 shots each). The method using Gaussian filtering is outlined for EMG onset time estimation in each channel and activation sequence profiling. Shots of each player revealed a persistent pattern of muscle activation. Profiles were plotted and insights with respect to player effectiveness were provided. Inspection of EMG dynamics revealed a pair of highest peaks in each channel as the hallmark of golf swing, and a custom application of peak detection for automatic extraction of swing segment was introduced. Various EMG features, encompassing 22 feature sets, were constructed. Feature sets were used individually and also in decision-level fusion for the prediction of shot effectiveness. The prediction of the target attribute, such as club head speed or ball carry distance, was investigated using random forest as the learner in detection and regression tasks. Detection evaluates the personal effectiveness of a shot with respect to the player-specific average, whereas regression estimates the value of target attribute, using EMG features as predictors. Fusion after decision optimization provided the best results: the equal error rate in detection was 24.3% for the speed and 31.7% for the distance; the mean absolute percentage error in regression was 3.2% for the speed and 6.4% for the distance. Proposed EMG feature sets were found to be useful, especially when used in combination. Rankings of feature sets indicated statistics for muscle activity in both the left and right body sides, correlation-based analysis of EMG dynamics and features derived from the properties of two highest peaks as important predictors of personal shot effectiveness. Activation sequence profiles helped in analyzing muscle orchestration during golf shot, exposing a specific avalanche pattern, but data from more players are needed for stronger conclusions. Results demonstrate that information arising from an EMG signal stream is useful for predicting golf shot success, in terms of club head speed and ball carry distance, with acceptable accuracy. Surface EMG data, collected with a goal to automatically evaluate golf player's performance, enables wearable computing in the field of ambient intelligence and has potential to enhance exercising of a long carry distance drive.
Verikas, Antanas; Vaiciukynas, Evaldas; Gelzinis, Adas; Parker, James; Olsson, M. Charlotte
2016-01-01
This study analyzes muscle activity, recorded in an eight-channel electromyographic (EMG) signal stream, during the golf swing using a 7-iron club and exploits information extracted from EMG dynamics to predict the success of the resulting shot. Muscles of the arm and shoulder on both the left and right sides, namely flexor carpi radialis, extensor digitorum communis, rhomboideus and trapezius, are considered for 15 golf players (∼5 shots each). The method using Gaussian filtering is outlined for EMG onset time estimation in each channel and activation sequence profiling. Shots of each player revealed a persistent pattern of muscle activation. Profiles were plotted and insights with respect to player effectiveness were provided. Inspection of EMG dynamics revealed a pair of highest peaks in each channel as the hallmark of golf swing, and a custom application of peak detection for automatic extraction of swing segment was introduced. Various EMG features, encompassing 22 feature sets, were constructed. Feature sets were used individually and also in decision-level fusion for the prediction of shot effectiveness. The prediction of the target attribute, such as club head speed or ball carry distance, was investigated using random forest as the learner in detection and regression tasks. Detection evaluates the personal effectiveness of a shot with respect to the player-specific average, whereas regression estimates the value of target attribute, using EMG features as predictors. Fusion after decision optimization provided the best results: the equal error rate in detection was 24.3% for the speed and 31.7% for the distance; the mean absolute percentage error in regression was 3.2% for the speed and 6.4% for the distance. Proposed EMG feature sets were found to be useful, especially when used in combination. Rankings of feature sets indicated statistics for muscle activity in both the left and right body sides, correlation-based analysis of EMG dynamics and features derived from the properties of two highest peaks as important predictors of personal shot effectiveness. Activation sequence profiles helped in analyzing muscle orchestration during golf shot, exposing a specific avalanche pattern, but data from more players are needed for stronger conclusions. Results demonstrate that information arising from an EMG signal stream is useful for predicting golf shot success, in terms of club head speed and ball carry distance, with acceptable accuracy. Surface EMG data, collected with a goal to automatically evaluate golf player’s performance, enables wearable computing in the field of ambient intelligence and has potential to enhance exercising of a long carry distance drive. PMID:27120604
NASA Astrophysics Data System (ADS)
Milroy, Conor; Martucci, Giovanni; O'Dowd, Colin
2010-05-01
The planetary boundary layer (PBL) top height detections have been retrieved by two ceilometers (Vaisala CL31 and Jenoptik CHM15K) and a microwave radiometer (RPG-HATPRO) based at the Mace Head Research station, Ireland, from the 8th to the 28th of June 2009 during the ICOS Mace Head campaign. Characteristic of this region, with warm waters, the marine boundary layer is typically 2-layered with a surface mixed layer (SML) and a decoupled residual or convective layer (DRCL), above which is the free troposphere (Kunz et al. 2002). The PBL data have been analyzed using a newly developed Temporal Height-Tracking (THT) algorithm (Martucci et al., 2010) for automatic detection of the independent SML and DRCL tops. Daily and weekly averages of the PBL data have been performed to smooth out the short term variability and assess the dependence of the PBL depth on different air masses advected over the Mace Head station. Moreover, a qualitative comparison between the ceilometer and radiometer PBL top detected values has been done to assess their consistency.
Liquid Biopsy in Head and Neck Cancer: Promises and Challenges.
Nonaka, T; Wong, D T W
2018-06-01
Head and neck cancer is the sixth most common cancer worldwide. It remains one of the leading causes of death, and its early detection is crucial. Liquid biopsy has emerged as a promising tool for detecting and monitoring the disease status of patients with early and advanced cancers. Circulating tumor DNA (ctDNA), circulating tumor cells (CTCs), and exosomal miRNAs have received enormous attention because of their apparent clinical implications. Analyses of these circulating biomarkers have paved the way for novel therapeutic approaches and precision medicine. A growing number of reports have implicated the use of circulating biomarkers for detection, treatment planning, response monitoring, and prognosis assessment. Although these new biomarkers can provide a wide range of possible clinical applications, no validated circulating biomarkers have yet been integrated into clinical practice for head and neck cancer. In this review, we summarize the current knowledge of circulating biomarkers in this field, focusing on their feasibility, limitations, and key areas of clinical applications. We also highlight recent advances in salivary diagnostics and their potential application in head and neck cancer.
The paradox of extreme high-altitude migration in bar-headed geese Anser indicus
Hawkes, L. A.; Balachandran, S.; Batbayar, N.; Butler, P. J.; Chua, B.; Douglas, D. C.; Frappell, P. B.; Hou, Y.; Milsom, W. K.; Newman, S. H.; Prosser, D. J.; Sathiyaselvam, P.; Scott, G. R.; Takekawa, J. Y.; Natsagdorj, T.; Wikelski, M.; Witt, M. J.; Yan, B.; Bishop, C. M.
2013-01-01
Bar-headed geese are renowned for migratory flights at extremely high altitudes over the world's tallest mountains, the Himalayas, where partial pressure of oxygen is dramatically reduced while flight costs, in terms of rate of oxygen consumption, are greatly increased. Such a mismatch is paradoxical, and it is not clear why geese might fly higher than is absolutely necessary. In addition, direct empirical measurements of high-altitude flight are lacking. We test whether migrating bar-headed geese actually minimize flight altitude and make use of favourable winds to reduce flight costs. By tracking 91 geese, we show that these birds typically travel through the valleys of the Himalayas and not over the summits. We report maximum flight altitudes of 7290 m and 6540 m for southbound and northbound geese, respectively, but with 95 per cent of locations received from less than 5489 m. Geese travelled along a route that was 112 km longer than the great circle (shortest distance) route, with transit ground speeds suggesting that they rarely profited from tailwinds. Bar-headed geese from these eastern populations generally travel only as high as the terrain beneath them dictates and rarely in profitable winds. Nevertheless, their migration represents an enormous challenge in conditions where humans and other mammals are only able to operate at levels well below their sea-level maxima. PMID:23118436
The paradox of extreme high-altitude migration in bar-headed geese Anser indicus
Hawkes, L.A.; Balachandran, S.; Batbayar, N.; Butler, P.J.; Chua, B.; Douglas, David C.; Frappell, P.B.; Hou, Y.; Milsom, W.K.; Newman, S.H.; Prosser, D.J.; Sathiyaselvam, P.; Scott, G.R.; Takekawa, John Y.; Natsagdorj, T.; Wikelski, M.; Witt, M.J.; Yan, B.; Bishop, C.M.
2012-01-01
Bar-headed geese are renowned for migratory flights at extremely high altitudes over the world's tallest mountains, the Himalayas, where partial pressure of oxygen is dramatically reduced while flight costs, in terms of rate of oxygen consumption, are greatly increased. Such a mismatch is paradoxical, and it is not clear why geese might fly higher than is absolutely necessary. In addition, direct empirical measurements of high-altitude flight are lacking. We test whether migrating bar-headed geese actually minimize flight altitude and make use of favourable winds to reduce flight costs. By tracking 91 geese, we show that these birds typically travel through the valleys of the Himalayas and not over the summits. We report maximum flight altitudes of 7290 m and 6540 m for southbound and northbound geese, respectively, but with 95 per cent of locations received from less than 5489 m. Geese travelled along a route that was 112 km longer than the great circle (shortest distance) route, with transit ground speeds suggesting that they rarely profited from tailwinds. Bar-headed geese from these eastern populations generally travel only as high as the terrain beneath them dictates and rarely in profitable winds. Nevertheless, their migration represents an enormous challenge in conditions where humans and other mammals are only able to operate at levels well below their sea-level maxima.
NASA Technical Reports Server (NTRS)
Bard, Steven (Inventor); Wu, Jiunn-Jeng (Inventor); Trimble, Curtis A. (Inventor)
1992-01-01
A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.
Quality assessment of MEG-to-MRI coregistrations
NASA Astrophysics Data System (ADS)
Sonntag, Hermann; Haueisen, Jens; Maess, Burkhard
2018-04-01
For high precision in source reconstruction of magnetoencephalography (MEG) or electroencephalography data, high accuracy of the coregistration of sources and sensors is mandatory. Usually, the source space is derived from magnetic resonance imaging (MRI). In most cases, however, no quality assessment is reported for sensor-to-MRI coregistrations. If any, typically root mean squares (RMS) of point residuals are provided. It has been shown, however, that RMS of residuals do not correlate with coregistration errors. We suggest using target registration error (TRE) as criterion for the quality of sensor-to-MRI coregistrations. TRE measures the effect of uncertainty in coregistrations at all points of interest. In total, 5544 data sets with sensor-to-head and 128 head-to-MRI coregistrations, from a single MEG laboratory, were analyzed. An adaptive Metropolis algorithm was used to estimate the optimal coregistration and to sample the coregistration parameters (rotation and translation). We found an average TRE between 1.3 and 2.3 mm at the head surface. Further, we observed a mean absolute difference in coregistration parameters between the Metropolis and iterative closest point algorithm of (1.9 +/- 15){\\hspace{0pt}}\\circ and (1.1 +/- 9) m. A paired sample t-test indicated a significant improvement in goal function minimization by using the Metropolis algorithm. The sampled parameters allowed computation of TRE on the entire grid of the MRI volume. Hence, we recommend the Metropolis algorithm for head-to-MRI coregistrations.
NASA Astrophysics Data System (ADS)
Bard, Steven; Wu, Jiunn-Jeng; Trimble, Curtis A.
1992-06-01
A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.
Aitkenhead, A H; Rowbottom, C G; Mackay, R I
2013-10-07
We report on the design of Marvin, a Model Anatomy for Radiotherapy Verification and audit In the head and Neck and present results demonstrating its use in the development of the Elekta volumetric modulated arc therapy (VMAT) technique at the Christie, and in the audit of TomoTherapy and Varian RapidArc at other institutions. The geometry of Marvin was generated from CT datasets of eight male and female patients lying in the treatment position, with removable inhomogeneities modelling the sinuses and mandible. A modular system allows the phantom to be used with a range of detectors, with the locations of the modules being based on an analysis of a range of typical treatment plans (27 in total) which were mapped onto the phantom geometry. Results demonstrate the use of Gafchromic EBT2/EBT3 film for measurement of relative dose in a plane through the target and organs-at-risk, and the use of a small-volume ionization chamber for measurement of absolute dose in the target and spinal cord. Measurements made during the development of the head and neck VMAT protocol at the Christie quantified the improvement in plan delivery resulting from the installation of the Elekta Integrity upgrade (which permits an effectively continuously variable dose rate), with plans delivered before and after the upgrade having 88.5 ± 9.4% and 98.0 ± 2.2% respectively of points passing a gamma analysis (at 4%, 4 mm, global). Audits of TomoTherapy and Varian RapidArc neck techniques at other institutions showed a similar quality of plan delivery as for post-Integrity Elekta VMAT: film measurements for both techniques had >99% of points passing a gamma analysis at the clinical criteria of 4%, 4 mm, global, and >95% of points passing at tighter criteria of 3%, 3 mm, global; and absolute dose measurements in the PTV and spinal cord were within 1.5% and 3.5% of the planned doses respectively for both techniques. The results demonstrate that Marvin is an efficient and effective means of assessing the quality of delivery of complex radiotherapy in the head and neck, and is a useful tool to assist development and audit of these techniques.
Marvin: an anatomical phantom for dosimetric evaluation of complex radiotherapy of the head and neck
NASA Astrophysics Data System (ADS)
Aitkenhead, A. H.; Rowbottom, C. G.; Mackay, R. I.
2013-10-01
We report on the design of Marvin, a Model Anatomy for Radiotherapy Verification and audit In the head and Neck and present results demonstrating its use in the development of the Elekta volumetric modulated arc therapy (VMAT) technique at the Christie, and in the audit of TomoTherapy and Varian RapidArc at other institutions. The geometry of Marvin was generated from CT datasets of eight male and female patients lying in the treatment position, with removable inhomogeneities modelling the sinuses and mandible. A modular system allows the phantom to be used with a range of detectors, with the locations of the modules being based on an analysis of a range of typical treatment plans (27 in total) which were mapped onto the phantom geometry. Results demonstrate the use of Gafchromic EBT2/EBT3 film for measurement of relative dose in a plane through the target and organs-at-risk, and the use of a small-volume ionization chamber for measurement of absolute dose in the target and spinal cord. Measurements made during the development of the head and neck VMAT protocol at the Christie quantified the improvement in plan delivery resulting from the installation of the Elekta Integrity upgrade (which permits an effectively continuously variable dose rate), with plans delivered before and after the upgrade having 88.5 ± 9.4% and 98.0 ± 2.2% respectively of points passing a gamma analysis (at 4%, 4 mm, global). Audits of TomoTherapy and Varian RapidArc neck techniques at other institutions showed a similar quality of plan delivery as for post-Integrity Elekta VMAT: film measurements for both techniques had >99% of points passing a gamma analysis at the clinical criteria of 4%, 4 mm, global, and >95% of points passing at tighter criteria of 3%, 3 mm, global; and absolute dose measurements in the PTV and spinal cord were within 1.5% and 3.5% of the planned doses respectively for both techniques. The results demonstrate that Marvin is an efficient and effective means of assessing the quality of delivery of complex radiotherapy in the head and neck, and is a useful tool to assist development and audit of these techniques.
Simpson, Tyler; Gauthier, Michel; Prochazka, Arthur
2010-02-01
Computer access can play an important role in employment and leisure activities following spinal cord injury. The authors' prior work has shown that a tooth-click detecting device, when paired with an optical head mouse, may be used by people with tetraplegia for controlling cursor movement and mouse button clicks. To compare the efficacy of tooth clicks to speech recognition and that of an optical head mouse to a gyrometer head mouse for cursor and mouse button control of a computer. Six able-bodied and 3 tetraplegic subjects used the devices listed above to produce cursor movements and mouse clicks in response to a series of prompts displayed on a computer. The time taken to move to and click on each target was recorded. The use of tooth clicks in combination with either an optical head mouse or a gyrometer head mouse can provide hands-free cursor movement and mouse button control at a speed of up to 22% of that of a standard mouse. Tooth clicks were significantly faster at generating mouse button clicks than speech recognition when paired with either type of head mouse device. Tooth-click detection performed better than speech recognition when paired with both the optical head mouse and the gyrometer head mouse. Such a system may improve computer access for people with tetraplegia.
A novel optical rotary encoder with eccentricity self-detection ability.
Li, Xuan; Ye, Guoyong; Liu, Hongzhong; Ban, Yaowen; Shi, Yongsheng; Yin, Lei; Lu, Bingheng
2017-11-01
Eccentricity error is the main error source of optical rotary encoders. Real-time detection and compensation of the eccentricity error is an effective way of improving the accuracy of rotary optical encoders. In this paper, a novel rotary optical encoder is presented to realize eccentricity self-detection. The proposed encoder adopts a spider-web-patterned scale grating as a measuring standard which is scanned by a dual-head scanning unit. Two scanning heads of the dual-head scanning unit, which are arranged orthogonally, have the function of scanning the periodic pattern of the scale grating along the angular and radial directions, respectively. By this means, synchronous measurement of angular and radial displacements of the scale grating is realized. This paper gives the details of the operating principle of the rotary optical encoder, developing and testing work of a prototype. The eccentricity self-detection result agrees well with the result measured by an optical microscope. The experimental result preliminarily proves the feasibility and effectiveness of the proposed optical encoder.
NASA Astrophysics Data System (ADS)
Ma, Ling; Lu, Guolan; Wang, Dongsheng; Wang, Xu; Chen, Zhuo Georgia; Muller, Susan; Chen, Amy; Fei, Baowei
2017-03-01
Hyperspectral imaging (HSI) is an emerging imaging modality that can provide a noninvasive tool for cancer detection and image-guided surgery. HSI acquires high-resolution images at hundreds of spectral bands, providing big data to differentiating different types of tissue. We proposed a deep learning based method for the detection of head and neck cancer with hyperspectral images. Since the deep learning algorithm can learn the feature hierarchically, the learned features are more discriminative and concise than the handcrafted features. In this study, we adopt convolutional neural networks (CNN) to learn the deep feature of pixels for classifying each pixel into tumor or normal tissue. We evaluated our proposed classification method on the dataset containing hyperspectral images from 12 tumor-bearing mice. Experimental results show that our method achieved an average accuracy of 91.36%. The preliminary study demonstrated that our deep learning method can be applied to hyperspectral images for detecting head and neck tumors in animal models.
A novel optical rotary encoder with eccentricity self-detection ability
NASA Astrophysics Data System (ADS)
Li, Xuan; Ye, Guoyong; Liu, Hongzhong; Ban, Yaowen; Shi, Yongsheng; Yin, Lei; Lu, Bingheng
2017-11-01
Eccentricity error is the main error source of optical rotary encoders. Real-time detection and compensation of the eccentricity error is an effective way of improving the accuracy of rotary optical encoders. In this paper, a novel rotary optical encoder is presented to realize eccentricity self-detection. The proposed encoder adopts a spider-web-patterned scale grating as a measuring standard which is scanned by a dual-head scanning unit. Two scanning heads of the dual-head scanning unit, which are arranged orthogonally, have the function of scanning the periodic pattern of the scale grating along the angular and radial directions, respectively. By this means, synchronous measurement of angular and radial displacements of the scale grating is realized. This paper gives the details of the operating principle of the rotary optical encoder, developing and testing work of a prototype. The eccentricity self-detection result agrees well with the result measured by an optical microscope. The experimental result preliminarily proves the feasibility and effectiveness of the proposed optical encoder.
NASA Astrophysics Data System (ADS)
Hara, Takeshi; Matoba, Naoto; Zhou, Xiangrong; Yokoi, Shinya; Aizawa, Hiroaki; Fujita, Hiroshi; Sakashita, Keiji; Matsuoka, Tetsuya
2007-03-01
We have been developing the CAD scheme for head and abdominal injuries for emergency medical care. In this work, we have developed an automated method to detect typical head injuries, rupture or strokes of brain. Extradural and subdural hematoma region were detected by comparing technique after the brain areas were registered using warping. We employ 5 normal and 15 stroke cases to estimate the performance after creating the brain model with 50 normal cases. Some of the hematoma regions were detected correctly in all of the stroke cases with no false positive findings on normal cases.
Meteoroid head echo polarization features studied by numerical electromagnetics modeling
NASA Astrophysics Data System (ADS)
Vertatschitsch, L. E.; Sahr, J. D.; Colestock, P.; Close, S.
2011-12-01
Meteoroid head echoes are radar returns associated with scatter from the dense plasma surrounding meteoroids striking the Earth's atmosphere. Such echoes are detected by high power, large aperture (HPLA) radars. Frequently such detections show large variations in signal strength that suggest constructive and destructive interference. Using the ARPA Long-Range Tracking and Instrumentation Radar (ALTAIR) we can also observe the polarization of the returns. Usually, scatter from head echoes resembles scatter from a small sphere; when transmitting right circular polarization (RC), the received signal consists entirely of left circular polarization (LC). For some detections, power is also received in the RC channel, which indicates the presence of a more complicated scattering process. Radar returns of a fragmenting meteoroid are simulated using a hard-sphere scattering model numerically evaluated in the resonant region of Mie scatter. The cross- and co-polar scattering cross-sections are computed for pairs of spheres lying within a few wavelengths, simulating the earliest stages of fragmentation upon atmospheric impact. The likelihood of detecting this sort of idealized fragmentation event is small, but this demonstrates the measurements that would result from such an event would display RC power comparable to LC power, matching the anomalous data. The resulting computations show that fragmentation is a consistent interpretation for these head echo radar returns.
Aravind, Gayatri; Darekar, Anuja; Fung, Joyce; Lamontagne, Anouk
2015-03-01
Persons with post-stroke visuospatial neglect (VSN) often collide with moving obstacles while walking. It is not well understood whether the collisions occur as a result of attentional-perceptual deficits caused by VSN or due to post-stroke locomotor deficits. We assessed individuals with VSN on a seated, joystick-driven obstacle avoidance task, thus eliminating the influence of locomotion. Twelve participants with VSN were tested on obstacle detection and obstacle avoidance tasks in a virtual environment that included three obstacles approaching head-on or 30 (°) contralesionally/ipsilesionally. Our results indicate that in the detection task, the contralesional and head-on obstacles were detected at closer proximities compared to the ipsilesional obstacle. For the avoidance task collisions were observed only for the contralesional and head-on obstacle approaches. For the contralesional obstacle approach, participants initiated their avoidance strategies at smaller distances from the obstacle and maintained smaller minimum distances from the obstacles. The distance at detection showed a negative association with the distance at the onset of avoidance strategy for all three obstacle approaches. We conclusion the observation of collisions with contralesional and head-on obstacles, in the absence of locomotor burden, provides evidence that attentional-perceptual deficits due to VSN, independent of post-stroke locomotor deficits, alter obstacle avoidance abilities.
Patient positioning in radiotherapy based on surface imaging using time of flight cameras
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilles, M., E-mail: marlene.gilles@univ-brest.fr
2016-08-15
Purpose: To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. Methods: A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, andmore » head and neck cancer patients. Results: The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. Conclusions: The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).« less
Patient positioning in radiotherapy based on surface imaging using time of flight cameras.
Gilles, M; Fayad, H; Miglierini, P; Clement, J F; Scheib, S; Cozzi, L; Bert, J; Boussion, N; Schick, U; Pradier, O; Visvikis, D
2016-08-01
To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, and head and neck cancer patients. The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).
Deng, Zhi-An; Wang, Guofeng; Hu, Ying; Cui, Yang
2016-01-01
This paper proposes a novel heading estimation approach for indoor pedestrian navigation using the built-in inertial sensors on a smartphone. Unlike previous approaches constraining the carrying position of a smartphone on the user’s body, our approach gives the user a larger freedom by implementing automatic recognition of the device carrying position and subsequent selection of an optimal strategy for heading estimation. We firstly predetermine the motion state by a decision tree using an accelerometer and a barometer. Then, to enable accurate and computational lightweight carrying position recognition, we combine a position classifier with a novel position transition detection algorithm, which may also be used to avoid the confusion between position transition and user turn during pedestrian walking. For a device placed in the trouser pockets or held in a swinging hand, the heading estimation is achieved by deploying a principal component analysis (PCA)-based approach. For a device held in the hand or against the ear during a phone call, user heading is directly estimated by adding the yaw angle of the device to the related heading offset. Experimental results show that our approach can automatically detect carrying positions with high accuracy, and outperforms previous heading estimation approaches in terms of accuracy and applicability. PMID:27187391
NASA Astrophysics Data System (ADS)
Wang, H. H.; Shi, Y. P.; Li, X. H.; Ni, K.; Zhou, Q.; Wang, X. H.
2018-03-01
In this paper, a scheme to measure the position of precision stages, with a high precision, is presented. The encoder is composed of a scale grating and a compact two-probe reading head, to read the zero position pulse signal and continuous incremental displacement signal. The scale grating contains different codes, multiple reference codes with different spacing superimposed onto the incremental grooves with an equal spacing structure. The codes of reference mask in the reading head is the same with the reference codes on the scale grating, and generate pulse signal to locate the reference position primarily when the reading head moves along the scale grating. After locating the reference position in a section by means of the pulse signal, the reference position can be located precisely with the amplitude of the incremental displacement signal. A kind of reference codes and scale grating were designed, and experimental results show that the primary precision of the design achieved is 1 μ m. The period of the incremental signal is 1μ m, and 1000/N nm precision can be achieved by subdivide the incremental signal in N times.
Particle swarm optimization algorithm based low cost magnetometer calibration
NASA Astrophysics Data System (ADS)
Ali, A. S.; Siddharth, S., Syed, Z., El-Sheimy, N.
2011-12-01
Inertial Navigation Systems (INS) consist of accelerometers, gyroscopes and a microprocessor provide inertial digital data from which position and orientation is obtained by integrating the specific forces and rotation rates. In addition to the accelerometers and gyroscopes, magnetometers can be used to derive the absolute user heading based on Earth's magnetic field. Unfortunately, the measurements of the magnetic field obtained with low cost sensors are corrupted by several errors including manufacturing defects and external electro-magnetic fields. Consequently, proper calibration of the magnetometer is required to achieve high accuracy heading measurements. In this paper, a Particle Swarm Optimization (PSO) based calibration algorithm is presented to estimate the values of the bias and scale factor of low cost magnetometer. The main advantage of this technique is the use of the artificial intelligence which does not need any error modeling or awareness of the nonlinearity. The estimated bias and scale factor errors from the proposed algorithm improve the heading accuracy and the results are also statistically significant. Also, it can help in the development of the Pedestrian Navigation Devices (PNDs) when combined with the INS and GPS/Wi-Fi especially in the indoor environments
Naruto, Norihito; Tannai, Hidenori; Nishikawa, Kazuma; Yamagishi, Kentaro; Hashimoto, Masahiko; Kawabe, Hideto; Kamisaki, Yuichi; Sumiya, Hisashi; Kuroda, Satoshi; Noguchi, Kyo
2018-02-01
One of the major applications of dual-energy computed tomography (DECT) is automated bone removal (BR). We hypothesized that the visualization of acute intracranial hemorrhage could be improved on BRCT by removing bone as it has the highest density tissue in the head. This preliminary study evaluated the efficacy of a DE BR algorithm for the head CT of trauma patients. Sixteen patients with acute intracranial hemorrhage within 1 day after head trauma were enrolled in this study. All CT examinations were performed on a dual-source dual-energy CT scanner. BRCT images were generated using the Bone Removal Application. Simulated standard CT and BRCT images were visually reviewed in terms of detectability (presence or absence) of acute hemorrhagic lesions. DECT depicted 28 epidural/subdural hemorrhages, 17 contusional hemorrhages, and 7 subarachnoid hemorrhages. In detecting epidural/subdural hemorrhage, BRCT [28/28 (100%)] was significantly superior to simulated standard CT [17/28 (61%)] (p = .001). In detecting contusional hemorrhage, BRCT [17/17 (100%)] was also significantly superior to simulated standard CT [11/17 (65%)] (p = .0092). BRCT was superior to simulated standard CT in detecting acute intracranial hemorrhage. BRCT could improve the detection of small intracranial hemorrhages, particularly those adjacent to bone, by removing bone that can interfere with the visualization of small acute hemorrhage. In an emergency such as head trauma, BRCT can be used as support imaging in combination with simulated standard CT and bone scale CT, although BRCT cannot replace a simulated standard CT.
Oliver, Jonathan M; Anzalone, Anthony J; Stone, Jason D; Turner, Stephanie M; Blueitt, Damond; Garrison, J Craig; Askow, Andrew T; Luedke, Joel A; Jagim, Andrew R
2018-05-29
OBJECTIVE Repetitive subconcussive head trauma is a consequence of participation in contact sports and may be linked to neurodegenerative diseases. The degree of neurological injury caused by subconcussive head trauma is not easily detectible, and this injury does not induce readily identifiable clinical signs or symptoms. Recent advancements in immunoassays make possible the detection and quantification of blood biomarkers linked to head trauma. Identification of a blood biomarker that can identify the extent of neurological injury associated with subconcussive head trauma may provide an objective measure for informed decisions concerning cumulative exposure to subconcussive head trauma. The purpose of the current study was to examine changes in the blood biomarkers of subconcussive head trauma over the course of an American football season. METHODS Thirty-five National Collegiate Athletic Association (NCAA) American football athletes underwent blood sampling throughout the course of a football season. Serial samples were obtained throughout the 2016 season, during which the number and magnitude of head impacts changed. Blood samples were analyzed for plasma concentrations of tau and serum concentrations of neurofilament light polypeptide (NF-L). Athletes were grouped based on their starter status, because athletes identified as starters are known to sustain a greater number of impacts. Between-group differences and time-course differences were assessed. RESULTS In nonstarters, plasma concentrations of tau decreased over the course of the season, with lower values observed in starters; this resulted in a lower area under the curve (AUC) (starters: 416.78 ± 129.17 pg/ml/day; nonstarters: 520.84 ± 163.19 pg/ml/day; p = 0.050). Plasma concentrations of tau could not be used to discern between starters and nonstarters. In contrast, serum concentrations of NF-L increased throughout the season as head impacts accumulated, specifically in those athletes categorized as starters. The higher serum concentrations of NF-L observed in starters resulted in a larger AUC (starters: 1605.03 ± 655.09 pg/ml/day; nonstarters: 1067.29 ± 272.33 pg/ml/day; p = 0.007). The AUC of the receiver operating characteristic curve analyses displayed fair to modest accuracy to identify athletes who were starters with the use of serum NF-L following periods of repetitive impacts. CONCLUSIONS The different patterns observed in serum NF-L and plasma tau concentrations provide preliminary evidence for the use of blood biomarkers to detect the neurological injury associated with repetitive subconcussive head trauma. Although further investigation is necessary, such findings might lay the foundation for the further development of an objective measure for the detection of neurological injury caused by subconcussive head trauma.
Mayo, Johnathan; Baur, Kilian; Wittmann, Frieder; Riener, Robert; Wolf, Peter
2018-01-01
Background Goal-directed reaching for real-world objects by humans is enabled through visual depth cues. In virtual environments, the number and quality of available visual depth cues is limited, which may affect reaching performance and quality of reaching movements. Methods We assessed three-dimensional reaching movements in five experimental groups each with ten healthy volunteers. Three groups used a two-dimensional computer screen and two groups used a head-mounted display. The first screen group received the typically recreated visual depth cues, such as aerial and linear perspective, occlusion, shadows, and texture gradients. The second screen group received an abstract minimal rendering lacking those. The third screen group received the cues of the first screen group and absolute depth cues enabled by retinal image size of a known object, which realized with visual renderings of the handheld device and a ghost handheld at the target location. The two head-mounted display groups received the same virtually recreated visual depth cues as the second or the third screen group respectively. Additionally, they could rely on stereopsis and motion parallax due to head-movements. Results and conclusion All groups using the screen performed significantly worse than both groups using the head-mounted display in terms of completion time normalized by the straight-line distance to the target. Both groups using the head-mounted display achieved the optimal minimum in number of speed peaks and in hand path ratio, indicating that our subjects performed natural movements when using a head-mounted display. Virtually recreated visual depth cues had a minor impact on reaching performance. Only the screen group with rendered handhelds could outperform the other screen groups. Thus, if reaching performance in virtual environments is in the main scope of a study, we suggest applying a head-mounted display. Otherwise, when two-dimensional screens are used, achievable performance is likely limited by the reduced depth perception and not just by subjects’ motor skills. PMID:29293512
Wermker, Kai; Brauckmann, Till; Klein, Martin; Haßfeld, Stefan; Schulze, Hans-Joachim; Hallermann, Christian
2015-09-01
In uncommon mucosal melanomas of the head and neck established prognostic factors are rare and controversially discussed. The purpose of this study was to evaluate outcome and value of S100/podoplanin and S100/CD31 double immunostaining in head and neck mucosal melanomas. Retrospectively, patients with head and neck mucosal melanomas treated between 1973 and 2008 were analyzed. S100/podoplanin and S100/CD31 immunostaining were performed to detect lymph vessel invasion (LVI) and blood vessel invasion (BVI). Predictive parameters for disease-specific survival (DSS) were identified using univariate and multivariate statistics. Forty-two patients with head and neck mucosal melanoma were included. Three-year, 5-year, and 10-year DSS rates were 59%, 44%, and 20%, respectively. Age above 70 years, occurrence of distant metastasis, LVI, and BVI were significantly associated with shorter DSS time (p < .05), whereas localization at the conjunctiva showed better outcome. S100/podoplanin and S100/CD31 double immunostaining detect reliable LVI and BVI in head and neck mucosal melanoma and both are associated significantly with worse prognosis. © 2014 Wiley Periodicals, Inc.
MACS-Mar: a real-time remote sensing system for maritime security applications
NASA Astrophysics Data System (ADS)
Brauchle, Jörg; Bayer, Steven; Hein, Daniel; Berger, Ralf; Pless, Sebastian
2018-04-01
The modular aerial camera system (MACS) is a development platform for optical remote sensing concepts, algorithms and special environments. For real-time services for maritime security (EMSec joint project), a new multi-sensor configuration MACS-Mar was realized. It consists of four co-aligned sensor heads in the visible RGB, near infrared (NIR, 700-950 nm), hyperspectral (HS, 450-900 nm) and thermal infrared (TIR, 7.5-14 µm) spectral range, a mid-cost navigation system, a processing unit and two data links. On-board image projection, cropping of redundant data and compression enable the instant generation of direct-georeferenced high-resolution image mosaics, automatic object detection, vectorization and annotation of floating objects on the water surface. The results were transmitted over a distance up to 50 km in real-time via narrow and broadband data links and were visualized in a maritime situation awareness system. For the automatic onboard detection of floating objects, a segmentation and classification workflow based on RGB, IR and TIR information was developed and tested. The completeness of the object detection in the experiment resulted in 95%, the correctness in 53%. Mostly, bright backwash of ships lead to an overestimation of the number of objects, further refinement using water homogeneity in the TIR, as implemented in the workflow, couldn't be carried out due to problems with the TIR sensor, else distinctly better results could have been expected. The absolute positional accuracy of the projected real-time imagery resulted in 2 m without postprocessing of images or navigation data, the relative measurement accuracy of distances is in the range of the image resolution, which is about 12 cm for RGB imagery in the EMSec experiment.
Sleep confers a benefit for retention of statistical language learning in 6.5month old infants.
Simon, Katharine N S; Werchan, Denise; Goldstein, Michael R; Sweeney, Lucia; Bootzin, Richard R; Nadel, Lynn; Gómez, Rebecca L
2017-04-01
Infants show robust ability to track transitional probabilities within language and can use this information to extract words from continuous speech. The degree to which infants remember these words across a delay is unknown. Given well-established benefits of sleep on long-term memory retention in adults, we examine whether sleep similarly facilitates memory in 6.5month olds. Infants listened to an artificial language for 7minutes, followed by a period of sleep or wakefulness. After a time-matched delay for sleep and wakefulness dyads, we measured retention using the head-turn-preference procedure. Infants who slept retained memory for the extracted words that was prone to interference during the test. Infants who remained awake showed no retention. Within the nap group, retention correlated with three electrophysiological measures (1) absolute theta across the brain, (2) absolute alpha across the brain, and (3) greater fronto-central slow wave activity (SWA). Copyright © 2016 Elsevier Inc. All rights reserved.
Influence of simulated weightlessness on maximal oxygen uptake of untrained rats
NASA Technical Reports Server (NTRS)
Overton, J. Michael; Tipton, Charles M.
1987-01-01
The purpose of this study was to determine the effect of hindlimb suspension on maximal oxygen uptake of rodents. Male Sprague-Dawley rats were assigned to head-down (HD) suspension, horizontal (HOZ) suspension, or cage (C) control for 6-9 days. Rats were tested for maximal oxygen uptake before and after surgical instrumentation (Doppler flow probes, carotid and jugular cannulae), and after suspension. Body weight was significantly decreased after suspension in both HD and HOZ groups, but was significantly increased in the C group. Absolute maximal O2 uptake (ml/min) was not different in the C group. However, because of their increased weight, relative maximal O2 uptake (ml/min per kg) was significantly reduced. In contrast, both relative and absolute maximal O2 uptake were significantly lower, following suspension, for the HD and HOZ groups. These preliminary results support the use of hindlimb suspension as an effective model to study the mechanism(s) of cardiovascular deconditioning.
Human Papilloma Virus (HPV) Induced Head & Neck Squamous Cell Carcinoma: A Comprehensive Retrospect
Nishat, Roquaiya; Ramachandra, Sujatha; Kumar, Harish; Bandyopadhyay, Alokenath
2015-01-01
Head and Neck Squamous Cell Carcinoma accounts for the sixth most common malignancy occurring worldwide with tobacco and alcohol being the two well established risk factors. In the recent years, substantial evidence has been obtained that Human Papilloma Virus (HPV) associated head and neck cancers are on the rise. This article provides an insight into the structure of HPV genome, molecular pathogenesis, detection methods and clinical implications of HPV positive Head and Neck Squamous Cell Carcinoma. PMID:26266234
Pulse laser head with monolithic thermally bonded microchip operating at 1.5 μm wavelength
NASA Astrophysics Data System (ADS)
Młyńczak, Jarosław; Kopczyński, Krzysztof; Belghachem, Nabil; Kisielewski, Jarosław; Stepień, Ryszard; Wychowaniec, Marek; Galas, Jacek; Litwin, Dariusz; CzyŻewski, Adam
2016-12-01
On the basis of thermally bonded Er,Yb:glass/Co:MALO microchip a laser head pumped by fiber coupled laser diode was designed. The performance of the laser head were investigated and the main output parameters were determined. The energy over 40 μJ in 3.8 ns pulse with repetition rate of 0.735 kHz was achieved. The laser head characterized by such parameters can successfully be used in tele-detection applications.
Absolute measurements of fast neutrons using yttrium.
Roshan, M V; Springham, S V; Rawat, R S; Lee, P; Krishnan, M
2010-08-01
Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f(n) approximately 4.1x10(-4) with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10(8) neutrons per discharge.
Chen, Jiyun; Xu, Xiaomin; Huang, Zhimei; Luo, Yuan; Tang, Lijuan; Jiang, Jian-Hui
2018-01-02
A novel dNAD platform (BEAMing LAMP) by combining emulsion micro-reactors, single-molecule magnetic capture and on-bead loop-mediated isothermal amplification has been developed for DNA detection, which enables absolute and high-precision quantification of a target with a detection limit of 300 copies.
Hydroxyurea and Growth in Young Children With Sickle Cell Disease
Houston, Patricia E.; Wang, Winfred C.; Iyer, Rathi V.; Goldsmith, Jonathan; Casella, James F.; Reed, Caroline K.; Rogers, Zora R.; Waclawiw, Myron A.; Thompson, Bruce
2014-01-01
BACKGROUND: Growth impairment is a known complication of sickle cell disease. Effects of hydroxyurea (HU) on growth in very young children are not known. METHODS: Height, weight, BMI, and head circumference (HC) were compared with World Health Organization (WHO) standards in BABY HUG, a multicenter, randomized, double-blinded, placebo-controlled 2-year clinical trial of HU in 193 children 9 to 18 months of age. Anthropometric data were closely monitored and converted to z scores by using WHO standardized algorithms for descriptive analyses. The treatment and placebo groups were compared longitudinally by using a mixed model analysis. RESULTS: At entry, the z scores of BABY HUG children were higher than WHO norms. After 2 years of HU or placebo treatment, there were no significant differences between the groups, except for the mean HC z scores at study exit (HU: +0.8 versus placebo: +1.0, P = .05). Baseline z scores were the best predictors of z scores at study exit. The absolute neutrophil count, absolute reticulocyte count, and total white blood cell count had significant negative correlations with growth measures. CONCLUSIONS: Both groups had normal or near normal anthropometric measures during the study. The HC z scores at study entry and exit were slightly greater than WHO norms. Higher baseline white blood cell count, absolute reticulocyte count, and absolute neutrophil count were associated with poorer growth. The significance of the slightly lower HC in the treatment group at study exit is not clear. Trends toward normalization of weight and height and effects on HC will be monitored in ongoing BABY HUG follow-up studies. PMID:25157002
Auditory, Vestibular and Cognitive Effects due to Repeated Blast Exposure on the Warfighter
2012-10-01
Gaze Horizontal (Left and Right) Description: The primary purpose of the Gaze Horizontal subtest was to detect nystagmus when the head is fixed and...to detect nystagmus when the head is fixed and the eyes are gazing off center from the primary (straight ahead) gaze position. This test is designed...physiological target area and examiner instructions for testing): Spontaneous Nystagmus Smooth Harmonic Acceleration (.01, .08, .32, .64, 1.75
Microwave hemorrhagic stroke detector
Haddad, Waleed S.; Trebes, James E.
2002-01-01
The microwave hemorrhagic stroke detector includes a low power pulsed microwave transmitter with a broad-band antenna for producing a directional beam of microwaves, an index of refraction matching cap placed over the patients head, and an array of broad-band microwave receivers with collection antennae. The system of microwave transmitter and receivers are scanned around, and can also be positioned up and down the axis of the patients head. The microwave hemorrhagic stroke detector is a completely non-invasive device designed to detect and localize blood pooling and clots or to measure blood flow within the head or body. The device is based on low power pulsed microwave technology combined with specialized antennas and tomographic methods. The system can be used for rapid, non-invasive detection of blood pooling such as occurs with hemorrhagic stroke in human or animal patients as well as for the detection of hemorrhage within a patient's body.
Microwave hemorrhagic stroke detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haddad, Waleed S; Trebes, James E
The microwave hemorrhagic stroke detector includes a low power pulsed microwave transmitter with a broad-band antenna for producing a directional beam of microwaves, an index of refraction matching cap placed over the patients head, and an array of broad-band microwave receivers with collection antennae. The system of microwave transmitter and receivers are scanned around, and can also be positioned up and down the axis of the patients head. The microwave hemorrhagic stroke detector is a completely non-invasive device designed to detect and localize blood pooling and clots or to measure blood flow within the head or body. The device ismore » based on low power pulsed microwave technology combined with specialized antennas and tomographic methods. The system can be used for rapid, non-invasive detection of blood pooling such as occurs with hemorrhagic stoke in human or animal patients as well as for the detection of hemorrhage within a patient's body.« less
CT detection of occult pneumothorax in head trauma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tocino, I.M.; Miller, M.H.; Frederick, P.R.
1984-11-01
A prospective evaluation for occult pneumothorax was performed in 25 consecutive patients with serious head trauma by combining a limited chest CT examination with the emergency head CT examination. Of 21 pneuomothoraces present in 15 patients, 11 (52%) were found only by chest CT and were not identified clinically or by supine chest radiograph. Because of pending therapeutic measures, chest tubes were placed in nine of the 11 occult pneumothoraces, regardless of the volume. Chest CT proved itself as the most sensitive method for detection of occult pneumothorax, permitting early chest tube placement to prevent transition to a tension pneumothoraxmore » during subsequent mechanical ventilation or emergency surgery under general anesthesia.« less
Explosive vapor detection payload for small robots
NASA Astrophysics Data System (ADS)
Stimac, Phil J.; Pettit, Michael; Wetzel, John P.; Haas, John W.
2013-05-01
Detection of explosive hazards is a critical component of enabling and improving operational mobility and protection of US Forces. The Autonomous Mine Detection System (AMDS) developed by the US Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate (NVESD) is addressing this challenge for dismounted soldiers. Under the AMDS program, ARA has developed a vapor sampling system that enhances the detection of explosive residues using commercial-off-the-shelf (COTS) sensors. The Explosives Hazard Trace Detection (EHTD) payload is designed for plug-and-play installation and operation on small robotic platforms, addressing critical Army needs for more safely detecting concealed or exposed explosives in areas such as culverts, walls and vehicles. In this paper, we describe the development, robotic integration and performance of the explosive vapor sampling system, which consists of a sampling "head," a vapor transport tube and an extendable "boom." The sampling head and transport tube are integrated with the boom, allowing samples to be collected from targeted surfaces up to 7-ft away from the robotic platform. During sample collection, an IR lamp in the sampling head is used to heat a suspected object/surface and the vapors are drawn through the heated vapor transport tube to an ion mobility spectrometer (IMS) for detection. The EHTD payload is capable of quickly (less than 30 seconds) detecting explosives such as TNT, PETN, and RDX at nanogram levels on common surfaces (brick, concrete, wood, glass, etc.).
49 CFR 214.337 - On-track safety procedures for lone workers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...
49 CFR 214.337 - On-track safety procedures for lone workers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...
49 CFR 214.337 - On-track safety procedures for lone workers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...
49 CFR 214.337 - On-track safety procedures for lone workers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD WORKPLACE SAFETY Roadway Worker Protection... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...
Are patient specific meshes required for EIT head imaging?
Jehl, Markus; Aristovich, Kirill; Faulkner, Mayo; Holder, David
2016-06-01
Head imaging with electrical impedance tomography (EIT) is usually done with time-differential measurements, to reduce time-invariant modelling errors. Previous research suggested that more accurate head models improved image quality, but no thorough analysis has been done on the required accuracy. We propose a novel pipeline for creation of precise head meshes from magnetic resonance imaging and computed tomography scans, which was applied to four different heads. Voltages were simulated on all four heads for perturbations of different magnitude, haemorrhage and ischaemia, in five different positions and for three levels of instrumentation noise. Statistical analysis showed that reconstructions on the correct mesh were on average 25% better than on the other meshes. However, the stroke detection rates were not improved. We conclude that a generic head mesh is sufficient for monitoring patients for secondary strokes following head trauma.
Trombley, Adrienne R.; Wachter, Leslie; Garrison, Jeffrey; Buckley-Beason, Valerie A.; Jahrling, Jordan; Hensley, Lisa E.; Schoepp, Randal J.; Norwood, David A.; Goba, Augustine; Fair, Joseph N.; Kulesh, David A.
2010-01-01
Viral hemorrhagic fever is caused by a diverse group of single-stranded, negative-sense or positive-sense RNA viruses belonging to the families Filoviridae (Ebola and Marburg), Arenaviridae (Lassa, Junin, Machupo, Sabia, and Guanarito), and Bunyaviridae (hantavirus). Disease characteristics in these families mark each with the potential to be used as a biological threat agent. Because other diseases have similar clinical symptoms, specific laboratory diagnostic tests are necessary to provide the differential diagnosis during outbreaks and for instituting acceptable quarantine procedures. We designed 48 TaqMan™-based polymerase chain reaction (PCR) assays for specific and absolute quantitative detection of multiple hemorrhagic fever viruses. Forty-six assays were determined to be virus-specific, and two were designated as pan assays for Marburg virus. The limit of detection for the assays ranged from 10 to 0.001 plaque-forming units (PFU)/PCR. Although these real-time hemorrhagic fever virus assays are qualitative (presence of target), they are also quantitative (measure a single DNA/RNA target sequence in an unknown sample and express the final results as an absolute value (e.g., viral load, PFUs, or copies/mL) on the basis of concentration of standard samples and can be used in viral load, vaccine, and antiviral drug studies. PMID:20439981
Chaste, Pauline; Klei, Lambertus; Sanders, Stephan J; Murtha, Michael T; Hus, Vanessa; Lowe, Jennifer K; Willsey, A Jeremy; Moreno-De-Luca, Daniel; Yu, Timothy W; Fombonne, Eric; Geschwind, Daniel; Grice, Dorothy E; Ledbetter, David H; Lord, Catherine; Mane, Shrikant M; Lese Martin, Christa; Martin, Donna M; Morrow, Eric M; Walsh, Christopher A; Sutcliffe, James S; State, Matthew W; Devlin, Bernie; Cook, Edwin H; Kim, Soo-Jeong
2013-10-15
Brain development follows a different trajectory in children with autism spectrum disorders (ASD) than in typically developing children. A proxy for neurodevelopment could be head circumference (HC), but studies assessing HC and its clinical correlates in ASD have been inconsistent. This study investigates HC and clinical correlates in the Simons Simplex Collection cohort. We used a mixed linear model to estimate effects of covariates and the deviation from the expected HC given parental HC (genetic deviation). After excluding individuals with incomplete data, 7225 individuals in 1891 families remained for analysis. We examined the relationship between HC/genetic deviation of HC and clinical parameters. Gender, age, height, weight, genetic ancestry, and ASD status were significant predictors of HC (estimate of the ASD effect = .2 cm). HC was approximately normally distributed in probands and unaffected relatives, with only a few outliers. Genetic deviation of HC was also normally distributed, consistent with a random sampling of parental genes. Whereas larger HC than expected was associated with ASD symptom severity and regression, IQ decreased with the absolute value of the genetic deviation of HC. Measured against expected values derived from covariates of ASD subjects, statistical outliers for HC were uncommon. HC is a strongly heritable trait, and population norms for HC would be far more accurate if covariates including genetic ancestry, height, and age were taken into account. The association of diminishing IQ with absolute deviation from predicted HC values suggests HC could reflect subtle underlying brain development and warrants further investigation. © 2013 Society of Biological Psychiatry.
Chaste, Pauline; Klei, Lambertus; Sanders, Stephan J.; Murtha, Michael T.; Hus, Vanessa; Lowe, Jennifer K.; Willsey, A. Jeremy; Moreno-De-Luca, Daniel; Yu, Timothy W.; Fombonne, Eric; Geschwind, Daniel; Grice, Dorothy E.; Ledbetter, David H.; Lord, Catherine; Mane, Shrikant M.; Martin, Christa Lese; Martin, Donna M.; Morrow, Eric M.; Walsh, Christopher A.; Sutcliffe, James S.; State, Matthew W.; Devlin, Bernie; Cook, Edwin H.; Kim, Soo-Jeong
2013-01-01
BACKGROUND Brain development follows a different trajectory in children with Autism Spectrum Disorders (ASD) than in typically developing children. A proxy for neurodevelopment could be head circumference (HC), but studies assessing HC and its clinical correlates in ASD have been inconsistent. This study investigates HC and clinical correlates in the Simons Simplex Collection cohort. METHODS We used a mixed linear model to estimate effects of covariates and the deviation from the expected HC given parental HC (genetic deviation). After excluding individuals with incomplete data, 7225 individuals in 1891 families remained for analysis. We examined the relationship between HC/genetic deviation of HC and clinical parameters. RESULTS Gender, age, height, weight, genetic ancestry and ASD status were significant predictors of HC (estimate of the ASD effect=0.2cm). HC was approximately normally distributed in probands and unaffected relatives, with only a few outliers. Genetic deviation of HC was also normally distributed, consistent with a random sampling of parental genes. Whereas larger HC than expected was associated with ASD symptom severity and regression, IQ decreased with the absolute value of the genetic deviation of HC. CONCLUSIONS Measured against expected values derived from covariates of ASD subjects, statistical outliers for HC were uncommon. HC is a strongly heritable trait and population norms for HC would be far more accurate if covariates including genetic ancestry, height and age were taken into account. The association of diminishing IQ with absolute deviation from predicted HC values suggests HC could reflect subtle underlying brain development and warrants further investigation. PMID:23746936
Pena, J D; Mello, P A; Hernandez, M R
2000-05-01
The purpose of this study was to identify elastic microfibrillar components fibrillin-1 and fibrillin-2 in optic nerve heads of adult normal and glaucomatous subjects, in cultured optic nerve head astrocytes (type 1B astrocytes), as well as fibrillin-1 in fetal optic nerve heads. To characterize synthesis and gene expression of microfibrillar proteins in human optic nerve heads and cultured type 1B astrocytes, light microscopy immunohistochemistry, in situ hybridization, and RT-PCR or Northern blots were performed. Our results demonstrated that fibrillin-1 was associated with blood vessels, astrocytes in the glial columns and cribriform plates, and with astrocyte processes in the nerve bundles in all samples. In glaucomatous optic nerves there was enhanced fibrillin-1 immunoreactivity, especially surrounding blood vessels. Fibrillin-2 was localized primarily to blood vessels in all samples, without qualitative differences between normal and glaucomatous samples. In fetal optic nerve heads fibrillin-1 mRNA was localized to glial cells and to the blood vessel walls. In adult optic nerve heads, there was little fibrillin-1 mRNA as detectable by in situ hybridization and RT-PCR. There was no detectable upregulation of fibrillin-1 mRNA in glaucoma. In cultured type 1B astrocytes, fibrillin-1 staining was mostly pericellular. There was little fibrillin-2 immunoreactivity. In conclusion, astrocytes from the optic nerve head deposit elastic microfibrillar components in situ and in vitro, with a predominance of fibrillin-1. Upregulation of fibrillin-1 mRNA was not observed in glaucoma, suggesting that increased transcription may occur early in the disease process. Cultures of type 1B astrocytes from the optic nerve head provides a useful model to study mechanisms regulating the interactions of elastin and the microfibrils in optic nerve head astrocytes.
Sudo, Hirotaka; O'driscoll, Michael; Nishiwaki, Kenji; Kawamoto, Yuji; Gammell, Philip; Schramm, Gerhard; Wertli, Toni; Prinz, Heino; Mori, Atsuhide; Sako, Kazuhiro
2012-01-01
The application of a head space analyzer for oxygen concentration was examined to develop a novel ampoule leak test method. Studies using ampoules filled with ethanol-based solution and with nitrogen in the headspace demonstrated that the head space analysis (HSA) method showed sufficient sensitivity in detecting an ampoule crack. The proposed method is the use of HSA in conjunction with the pretreatment of an overpressurising process known as bombing to facilitate the oxygen flow through the crack in the ampoule. The method was examined in comparative studies with a conventional dye ingress method, and the results showed that the HSA method exhibits sensitivity superior to the dye method. The results indicate that the HSA method in combination with the bombing treatment provides potential application as a leak test for the detection of container defects not only for ampoule products with ethanol-based solutions, but also for testing lyophilized products in vials with nitrogen in the head space. The application of a head space analyzer for oxygen concentration was examined to develop a novel ampoule leak test method. The proposed method is the use of head space analysis (HSA) in conjunction with the pretreatment of an overpressurising process known as bombing to facilitate oxygen flow through the crack in the ampoule for use in routine production. The result of the comparative study with a conventional dye leak test method indicates that the HSA method in combination with the bombing treatment can be used as a leak test method, enabling detection of container defects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, J; Sisniega, A; Zbijewski, W
Purpose: To design a dedicated x-ray cone-beam CT (CBCT) system suitable to deployment at the point-of-care and offering reliable detection of acute intracranial hemorrhage (ICH), traumatic brain injury (TBI), stroke, and other head and neck injuries. Methods: A comprehensive task-based image quality model was developed to guide system design and optimization of a prototype head scanner suitable to imaging of acute TBI and ICH. Previously reported models were expanded to include the effects of x-ray scatter correction necessary for detection of low contrast ICH and the contribution of bit depth (digitization noise) to imaging performance. Task-based detectablity index provided themore » objective function for optimization of system geometry, x-ray source, detector type, anti-scatter grid, and technique at 10–25 mGy dose. Optimal characteristics were experimentally validated using a custom head phantom with 50 HU contrast ICH inserts imaged on a CBCT imaging bench allowing variation of system geometry, focal spot size, detector, grid selection, and x-ray technique. Results: The model guided selection of system geometry with a nominal source-detector distance 1100 mm and optimal magnification of 1.50. Focal spot size ∼0.6 mm was sufficient for spatial resolution requirements in ICH detection. Imaging at 90 kVp yielded the best tradeoff between noise and contrast. The model provided quantitation of tradeoffs between flat-panel and CMOS detectors with respect to electronic noise, field of view, and readout speed required for imaging of ICH. An anti-scatter grid was shown to provide modest benefit in conjunction with post-acquisition scatter correction. Images of the head phantom demonstrate visualization of millimeter-scale simulated ICH. Conclusions: Performance consistent with acute TBI and ICH detection is feasible with model-based system design and robust artifact correction in a dedicated head CBCT system. Further improvements can be achieved with incorporation of model-based iterative reconstruction techniques also within the scope of the task-based optimization framework. David Foos and Xiaohui Wang are employees of Carestream Health.« less
Absolute detector calibration using twin beams.
Peřina, Jan; Haderka, Ondřej; Michálek, Václav; Hamar, Martin
2012-07-01
A method for the determination of absolute quantum detection efficiency is suggested based on the measurement of photocount statistics of twin beams. The measured histograms of joint signal-idler photocount statistics allow us to eliminate an additional noise superimposed on an ideal calibration field composed of only photon pairs. This makes the method superior above other approaches presently used. Twin beams are described using a paired variant of quantum superposition of signal and noise.
Universal Head Ultrasound Screening in Full-term Neonates: A Retrospective Analysis of 6771 Infants.
Ballardini, Elisa; Tarocco, Anna; Rosignoli, Chiara; Baldan, Alessandro; Borgna-Pignatti, Caterina; Garani, Giampaolo
2017-06-01
Full-term neonates may have asymptomatic cranial injuries at birth and head ultrasound screening could be useful for early diagnosis. The aim of this study was to assess the prevalence and type of intracranial abnormalities and the usefulness of head ultrasound screening in these infants. Head ultrasound screening was performed on all full-term neonates (gestational age between 37 and 42 weeks), born at Sant'Anna University Hospital of Ferrara, Italy, from June 1, 2008 through May 31, 2013. Ultrasound findings were categorized into three groups: normal, minor, and major anomalies. All full-term neonates (6771) born at our hospital underwent head ultrasound screening. One hundred fourteen of 6771 (1.7%) presented ultrasound abnormalities, whereas 6657 were normal or exhibited insignificant findings. In 101 of 114 (88.6%), abnormalities were minor, and only 13 infants had major abnormalities (0.19% of all full-term newborns). All neonates with major abnormalities presented with either microcephaly or abnormal neurological evaluations. Only one individual with major abnormalities was detected exclusively by ultrasound. The number of significant anomalies detected by head ultrasound screening in asymptomatic full-term neonates born during the study period was low. Therefore, there is no indication for routine general head ultrasound screening in these patients. However, even if low, in neonates who have neurological abnormalities, risk factors or suspected brain malformations, head ultrasound screening may play an important role in the early diagnosis of intracranial anomalies. Copyright © 2017 Elsevier Inc. All rights reserved.
Guidelines for Head Tactile Communication
2010-03-01
significant effects were explored using least significant difference ( LSD ). The mean static force created on the head by the headband was 0.47 N. Due to...differences in thresholds attributable to head location, frequency, and noise condition, and significant effects were explored using LSD . The mean...Stuart, M.; Turman, A. B.; Shaw , J.; Walsh, N.; Nguyen, V. Effects of Aging on Vibration Detection Thresholds at Various Body Regions. BMC Geriatrics
Head lice infestations: A clinical update.
Cummings, Carl; Finlay, Jane C; MacDonald, Noni E
2018-02-01
Head lice ( Pediculus humanus capitis ) infestations are not a primary health hazard or a vector for disease, but they are a societal problem with substantial costs. Diagnosis of head lice infestation requires the detection of a living louse. Although pyrethrins and permethrin remain first-line treatments in Canada, isopropyl myristate/ST-cyclomethicone solution and dimeticone can be considered as second-line therapies when there is evidence of treatment failure.
Adaptive algorithm of magnetic heading detection
NASA Astrophysics Data System (ADS)
Liu, Gong-Xu; Shi, Ling-Feng
2017-11-01
Magnetic data obtained from a magnetic sensor usually fluctuate in a certain range, which makes it difficult to estimate the magnetic heading accurately. In fact, magnetic heading information is usually submerged in noise because of all kinds of electromagnetic interference and the diversity of the pedestrian’s motion states. In order to solve this problem, a new adaptive algorithm based on the (typically) right-angled corridors of a building or residential buildings is put forward to process heading information. First, a 3D indoor localization platform is set up based on MPU9250. Then, several groups of data are measured by changing the experimental environment and pedestrian’s motion pace. The raw data from the attached inertial measurement unit are calibrated and arranged into a time-stamped array and written to a data file. Later, the data file is imported into MATLAB for processing and analysis using the proposed adaptive algorithm. Finally, the algorithm is verified by comparison with the existing algorithm. The experimental results show that the algorithm has strong robustness and good fault tolerance, which can detect the heading information accurately and in real-time.
NASA Astrophysics Data System (ADS)
Kajimoto, Tsuyoshi; Shigyo, Nobuhiro; Sanami, Toshiya; Ishibashi, Kenji; Haight, Robert C.; Fotiades, Nikolaos
2011-02-01
Absolute neutron response functions and detection efficiencies of an NE213 liquid scintillator that was 12.7 cm in diameter and 12.7 cm in thickness were measured for neutron energies between 15 and 600 MeV at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. The experiment was performed with continuous-energy neutrons on a spallation neutron source by 800-MeV proton incidence. The incident neutron flux was measured using a 238U fission ionization chamber. Measured response functions and detection efficiencies were compared with corresponding calculations using the SCINFUL-QMD code. The calculated and experimental values were in good agreement for data below 70 MeV. However, there were discrepancies in the energy region between 70 and 150 MeV. Thus, the code was partly modified and the revised code provided better agreement with the experimental data.
Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup
2018-01-01
The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.
Tineshev, Slavi At
2010-01-01
It is impossible to give an objective anthropologic assessment of the overall physical development of a child's body during the time of intensive growth (7-17 years) without taking into account the age and gender changes in the absolute and relative head and face measurements. Head growth has specific characteristics that makes it different from the growth of other parts of the body. The head of a child differs from the head of an adult not only by metric characteristics but also by the proportions between the different head measurements. Growth and proportionality of the head comply with the general growth pattern, but there are also certain regional, populational and temporal differences. That was the reason why we conducted a study targeted at children and adolescents from the region of the Eastern Rhodopes. The aim Of the present study was to determine the growth dynamics in between-gender and between-age aspects of the variables characterizing the neurocranium and facial cranium, and establish the tendency and direction of the secular changes, The study included 1481 children and adolescents (699 boys and 782 girls) aged 7 to 17 years that were examined using the classical methodology of Martin-Saller (1957). Head length, width, height and circumference, as well as face width, mandible width, morphological and physiognomic height of the face were measured. Head index, morphological face index and jugulormandibular index were calculated using standard formulas. The secular changes were analyzed comparing data from 1907 and 1960 with the data of the present study. The head index classified the children from both genders and all age groups as mesocephals. The girls from the study region had a relatively greater mandible width and boys - relatively greater face width. In the beginning of the growth period wider face forms prevailed especially in the girls, while narrower face forms were more characteristic for the adolescence and postadolescence and better manifested in the boys. Throughout the entire study period the boys presented with greater measurements of the neurocranium and facial cranium than the girls. For both genders the increase in the neurocranium measurements anticipates that in the facial cranium measurements. In the examined children and adolescents the width cephalometric variables complete their growth earlier than the height variables. The head circumference and head width decrease, while the differences in the head length and facial height increase in both genders and all age groups in the end of the 20th and beginning of the 21st century.
In-the-wild facial expression recognition in extreme poses
NASA Astrophysics Data System (ADS)
Yang, Fei; Zhang, Qian; Zheng, Chi; Qiu, Guoping
2018-04-01
In the computer research area, facial expression recognition is a hot research problem. Recent years, the research has moved from the lab environment to in-the-wild circumstances. It is challenging, especially under extreme poses. But current expression detection systems are trying to avoid the pose effects and gain the general applicable ability. In this work, we solve the problem in the opposite approach. We consider the head poses and detect the expressions within special head poses. Our work includes two parts: detect the head pose and group it into one pre-defined head pose class; do facial expression recognize within each pose class. Our experiments show that the recognition results with pose class grouping are much better than that of direct recognition without considering poses. We combine the hand-crafted features, SIFT, LBP and geometric feature, with deep learning feature as the representation of the expressions. The handcrafted features are added into the deep learning framework along with the high level deep learning features. As a comparison, we implement SVM and random forest to as the prediction models. To train and test our methodology, we labeled the face dataset with 6 basic expressions.
A Context-Aware EEG Headset System for Early Detection of Driver Drowsiness.
Li, Gang; Chung, Wan-Young
2015-08-21
Driver drowsiness is a major cause of mortality in traffic accidents worldwide. Electroencephalographic (EEG) signal, which reflects the brain activities, is more directly related to drowsiness. Thus, many Brain-Machine-Interface (BMI) systems have been proposed to detect driver drowsiness. However, detecting driver drowsiness at its early stage poses a major practical hurdle when using existing BMI systems. This study proposes a context-aware BMI system aimed to detect driver drowsiness at its early stage by enriching the EEG data with the intensity of head-movements. The proposed system is carefully designed for low-power consumption with on-chip feature extraction and low energy Bluetooth connection. Also, the proposed system is implemented using JAVA programming language as a mobile application for on-line analysis. In total, 266 datasets obtained from six subjects who participated in a one-hour monotonous driving simulation experiment were used to evaluate this system. According to a video-based reference, the proposed system obtained an overall detection accuracy of 82.71% for classifying alert and slightly drowsy events by using EEG data alone and 96.24% by using the hybrid data of head-movement and EEG. These results indicate that the combination of EEG data and head-movement contextual information constitutes a robust solution for the early detection of driver drowsiness.
A Context-Aware EEG Headset System for Early Detection of Driver Drowsiness
Li, Gang; Chung, Wan-Young
2015-01-01
Driver drowsiness is a major cause of mortality in traffic accidents worldwide. Electroencephalographic (EEG) signal, which reflects the brain activities, is more directly related to drowsiness. Thus, many Brain-Machine-Interface (BMI) systems have been proposed to detect driver drowsiness. However, detecting driver drowsiness at its early stage poses a major practical hurdle when using existing BMI systems. This study proposes a context-aware BMI system aimed to detect driver drowsiness at its early stage by enriching the EEG data with the intensity of head-movements. The proposed system is carefully designed for low-power consumption with on-chip feature extraction and low energy Bluetooth connection. Also, the proposed system is implemented using JAVA programming language as a mobile application for on-line analysis. In total, 266 datasets obtained from six subjects who participated in a one-hour monotonous driving simulation experiment were used to evaluate this system. According to a video-based reference, the proposed system obtained an overall detection accuracy of 82.71% for classifying alert and slightly drowsy events by using EEG data alone and 96.24% by using the hybrid data of head-movement and EEG. These results indicate that the combination of EEG data and head-movement contextual information constitutes a robust solution for the early detection of driver drowsiness. PMID:26308002
237Np absolute delayed neutron yield measurements
NASA Astrophysics Data System (ADS)
Doré, D.; Ledoux, X.; Nolte, R.; Gagnon-Moisan, F.; Thulliez, L.; Litaize, O.; Roettger, S.; Serot, O.
2017-09-01
237Np absolute delayed neutron yields have been measured at different incident neutron energies from 1.5 to 16 MeV. The experiment was performed at the Physikalisch-Technische Bundesanstalt (PTB) facility where the Van de Graaff accelerator and the cyclotron CV28 delivered 9 different neutron energy beams using p+T, d+D and d+T reactions. The detection system is made up of twelve 3He tubes inserted into a polyethylene cylinder. In this paper, the experimental setup and the data analysis method are described. The evolution of the absolute DN yields as a function of the neutron incident beam energies are presented and compared to experimental data found in the literature and data from the libraries.
Automated reference-free detection of motion artifacts in magnetic resonance images.
Küstner, Thomas; Liebgott, Annika; Mauch, Lukas; Martirosian, Petros; Bamberg, Fabian; Nikolaou, Konstantin; Yang, Bin; Schick, Fritz; Gatidis, Sergios
2018-04-01
Our objectives were to provide an automated method for spatially resolved detection and quantification of motion artifacts in MR images of the head and abdomen as well as a quality control of the trained architecture. T1-weighted MR images of the head and the upper abdomen were acquired in 16 healthy volunteers under rest and under motion. Images were divided into overlapping patches of different sizes achieving spatial separation. Using these patches as input data, a convolutional neural network (CNN) was trained to derive probability maps for the presence of motion artifacts. A deep visualization offers a human-interpretable quality control of the trained CNN. Results were visually assessed on probability maps and as classification accuracy on a per-patch, per-slice and per-volunteer basis. On visual assessment, a clear difference of probability maps was observed between data sets with and without motion. The overall accuracy of motion detection on a per-patch/per-volunteer basis reached 97%/100% in the head and 75%/100% in the abdomen, respectively. Automated detection of motion artifacts in MRI is feasible with good accuracy in the head and abdomen. The proposed method provides quantification and localization of artifacts as well as a visualization of the learned content. It may be extended to other anatomic areas and used for quality assurance of MR images.
242Pu absolute neutron-capture cross section measurement
NASA Astrophysics Data System (ADS)
Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; O'Donnell, J. M.; Ullmann, J. L.
2017-09-01
The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. During target fabrication, a small amount of 239Pu was added to the active target so that the absolute scale of the 242Pu(n,γ) cross section could be set according to the known 239Pu(n,f) resonance at En,R = 7.83 eV. The relative scale of the 242Pu(n,γ) cross section covers four orders of magnitude for incident neutron energies from thermal to ≈ 40 keV. The cross section reported in ENDF/B-VII.1 for the 242Pu(n,γ) En,R = 2.68 eV resonance was found to be 2.4% lower than the new absolute 242Pu(n,γ) cross section.
Classifying and Standardizing Panfacial Trauma With a New Bony Facial Trauma Score.
Casale, Garrett G A; Fishero, Brian A; Park, Stephen S; Sochor, Mark; Heltzel, Sara B; Christophel, J Jared
2017-01-01
The practice of facial trauma surgery would benefit from a useful quantitative scale that measures the extent of injury. To develop a facial trauma scale that incorporates only reducible fractures and is able to be reliably communicated to health care professionals. A cadaveric tissue study was conducted from October 1 to 3, 2014. Ten cadaveric heads were subjected to various degrees of facial trauma by dropping a fixed mass onto each head. The heads were then imaged with fine-cut computed tomography. A Bony Facial Trauma Scale (BFTS) for grading facial trauma was developed based only on clinically relevant (reducible) fractures. The traumatized cadaveric heads were then scored using this scale as well as 3 existing scoring systems. Regression analysis was used to determine correlation between degree of incursion of the fixed mass on the cadaveric heads and trauma severity as rated by the scoring systems. Statistical analysis was performed to determine correlation of the scores obtained using the BFTS with those of the 3 existing scoring systems. Scores obtained using the BFTS were not correlated with dentition (95% CI, -0.087 to 1.053; P = .08; measured as absolute number of teeth) or age of the cadaveric donor (95% CI, -0.068 to 0.944; P = .08). Facial trauma scores. Among all 10 cadaveric specimens (9 male donors and 1 female donor; age range, 41-87 years; mean age, 57.2 years), the facial trauma scores obtained using the BFTS correlated with depth of penetration of the mass into the face (odds ratio, 4.071; 95% CI, 1.676-6.448) P = .007) when controlling for presence of dentition and age. The BFTS scores also correlated with scores obtained using 3 existing facial trauma models (Facial Fracture Severity Scale, rs = 0.920; Craniofacial Disruption Score, rs = 0.945; and ZS Score, rs = 0.902; P < .001 for all 3 models). In addition, the BFTS was found to have excellent interrater reliability (0.908; P = .001), which was similar to the interrater reliability of the other 3 tested trauma scales. Scores obtained using the BFTS were not correlated with dentition (odds ratio, .482; 95% CI, -0.087 to 1.053; P = .08; measured as absolute number of teeth) or age of the cadaveric donor (odds ratio, .436; 95% CI, -0.068 to 0.944; P = .08). Facial trauma severity as measured by the BFTS correlated with depth of penetration of the fixed mass into the face. In this study, the BFTS was clinically relevant, had high fidelity in communicating the fractures sustained in facial trauma, and correlated well with previously validated models. NA.
Psychophysical Criteria for Visual Simulation Systems.
1980-05-01
definitive data were found to estab- lish detection thresholds; therefore, this is one area where a psycho- physical study was recommended. Differential size...The specific functional relationships needinq quantification were the following: 1. The effect of Horizontal Aniseikonia on Target Detection and...Transition Technique 6. The Effects of Scene Complexity and Separation on the Detection of Scene Misalignment 7. Absolute Brightness Levels in
Chaumeau, V; Andolina, C; Fustec, B; Tuikue Ndam, N; Brengues, C; Herder, S; Cerqueira, D; Chareonviriyaphap, T; Nosten, F; Corbel, V
2016-01-01
Quantitative real-time polymerase chain reaction (qrtPCR) has made a significant improvement for the detection of Plasmodium in anopheline vectors. A wide variety of primers has been used in different assays, mostly adapted from molecular diagnosis of malaria in human. However, such an adaptation can impact the sensitivity of the PCR. Therefore we compared the sensitivity of five primer sets with different molecular targets on blood stages, sporozoites and oocysts standards of Plasmodium falciparum (Pf) and P. vivax (Pv). Dilution series of standard DNA were used to discriminate between methods at low concentrations of parasite and to generate standard curves suitable for the absolute quantification of Plasmodium sporozoites. Our results showed that the best primers to detect blood stages were not necessarily the best ones to detect sporozoites. Absolute detection threshold of our qrtPCR assay varied between 3.6 and 360 Pv sporozoites and between 6 and 600 Pf sporozoites per mosquito according to the primer set used in the reaction mix. In this paper, we discuss the general performance of each primer set and highlight the need to use efficient detection methods for transmission studies.
Chaumeau, V.; Andolina, C.; Fustec, B.; Tuikue Ndam, N.; Brengues, C.; Herder, S.; Cerqueira, D.; Chareonviriyaphap, T.; Nosten, F.; Corbel, V.
2016-01-01
Quantitative real-time polymerase chain reaction (qrtPCR) has made a significant improvement for the detection of Plasmodium in anopheline vectors. A wide variety of primers has been used in different assays, mostly adapted from molecular diagnosis of malaria in human. However, such an adaptation can impact the sensitivity of the PCR. Therefore we compared the sensitivity of five primer sets with different molecular targets on blood stages, sporozoites and oocysts standards of Plasmodium falciparum (Pf) and P. vivax (Pv). Dilution series of standard DNA were used to discriminate between methods at low concentrations of parasite and to generate standard curves suitable for the absolute quantification of Plasmodium sporozoites. Our results showed that the best primers to detect blood stages were not necessarily the best ones to detect sporozoites. Absolute detection threshold of our qrtPCR assay varied between 3.6 and 360 Pv sporozoites and between 6 and 600 Pf sporozoites per mosquito according to the primer set used in the reaction mix. In this paper, we discuss the general performance of each primer set and highlight the need to use efficient detection methods for transmission studies. PMID:27441839
Colloid cyst mimicking intracranial hemorrhage after head trauma.
Buyukkaya, Ayla; Buyukkaya, Ramazan; Özel, Mehmet Ali; Sarıtas, Ayhan
2015-02-01
Trauma patients consist vast majority of the patients who admit to emergency department, and most of them have a head trauma. A 58-year-old patient was taken to emergency department with head trauma, and a hyperdense lesion neighboring to third ventricle was detected. A diagnosis of colloid cyst was made in the patient who was being followed up for hemorrhage. In patients with head trauma, colloid cyst may easly be confused with intracranial hemorrhage due to hyperdensity. The aim of this report is to emphasize the importance of clinical thinking in the differential diagnosis of hyperdense lesion on computed tomography imaging of a patient with head injury.
Tascone, Oriane; Fillâtre, Yoann; Roy, Céline; Meierhenrich, Uwe J
2015-05-27
This study investigates the concentrations of 54 multiclass pesticides during the transformation processes from rose petal to concrete and absolute using roses spiked with pesticides as a model. The concentrations of the pesticides were followed during the process of transforming the spiked rose flowers from an organic field into concrete and then into absolute. The rose flowers, the concrete, and the absolute, as well as their transformation intermediates, were analyzed for pesticide content using gas chromatography/tandem mass spectrometry. We observed that all the pesticides were extracted and concentrated in the absolute, with the exception of three molecules: fenthion, fenamiphos, and phorate. Typical pesticides were found to be concentrated by a factor of 100-300 from the rose flowers to the rose absolute. The observed effect of pesticide enrichment was also studied in roses and their extracts from four classically phytosanitary treated fields. Seventeen pesticides were detected in at least one of the extracts. Like the case for the spiked samples in our model, the pesticides present in the rose flowers from Turkey were concentrated in the absolute. Two pesticides, methidathion and chlorpyrifos, were quantified in the rose flowers at approximately 0.01 and 0.01-0.05 mg kg(-1), respectively, depending on the treated field. The concentrations determined for the corresponding rose absolutes were 4.7 mg kg(-1) for methidathion and 0.65-27.25 mg kg(-1) for chlorpyrifos.
A Simple Two Aircraft Conflict Resolution Algorithm
NASA Technical Reports Server (NTRS)
Chatterji, Gano B.
1999-01-01
Conflict detection and resolution methods are crucial for distributed air-ground traffic management in which the crew in the cockpit, dispatchers in operation control centers and air traffic controllers in the ground-based air traffic management facilities share information and participate in the traffic flow and traffic control imctions.This paper describes a conflict detection and a conflict resolution method. The conflict detection method predicts the minimum separation and the time-to-go to the closest point of approach by assuming that both the aircraft will continue to fly at their current speeds along their current headings. The conflict resolution method described here is motivated by the proportional navigation algorithm. It generates speed and heading commands to rotate the line-of-sight either clockwise or counter-clockwise for conflict resolution. Once the aircraft achieve a positive range-rate and no further conflict is predicted, the algorithm generates heading commands to turn back the aircraft to their nominal trajectories. The speed commands are set to the optimal pre-resolution speeds. Six numerical examples are presented to demonstrate the conflict detection and resolution method.
Dengler, Adam K; Wightman, R Mark; McCarty, Gregory S
2015-10-20
Fast-scan cyclic voltammetry (FSCV) has attracted attention for studying in vivo neurotransmission due to its subsecond temporal resolution, selectivity, and sensitivity. Traditional FSCV measurements use background subtraction to isolate changes in the local electrochemical environment, providing detailed information on fluctuations in the concentration of electroactive species. This background subtraction removes information about constant or slowly changing concentrations. However, determination of background concentrations is still important for understanding functioning brain tissue. For example, neural activity is known to consume oxygen and produce carbon dioxide which affects local levels of oxygen and pH. Here, we present a microfabricated microelectrode array which uses FSCV to detect the absolute levels of oxygen and pH in vitro. The sensor is a collector-generator electrode array with carbon microelectrodes spaced 5 μm apart. In this work, a periodic potential step is applied at the generator producing transient local changes in the electrochemical environment. The collector electrode continuously performs FSCV enabling these induced changes in concentration to be recorded with the sensitivity and selectivity of FSCV. A negative potential step applied at the generator produces a transient local pH shift at the collector. The generator-induced pH signal is detected using FSCV at the collector and correlated to absolute solution pH by postcalibration of the anodic peak position. In addition, in oxygenated solutions a negative potential step at the generator produces hydrogen peroxide by reducing oxygen. Hydrogen peroxide is detected with FSCV at the collector electrode, and the magnitude of the oxidative peak is proportional to absolute oxygen concentrations. Oxygen interference on the pH signal is minimal and can be accounted for with a postcalibration.
An experiment to measure the one-way velocity of propagation of electromagnetic radiation
NASA Technical Reports Server (NTRS)
Kolen, P.; Torr, D. G.
1982-01-01
An experiment involving commercially available instrumentation to measure the velocity of the earth with respect to absolute space is described. The experiment involves the measurement of the one-way propagation velocity of electromagnetic radiation down a high-quality coaxial cable. It is demonstrated that the experiment is both physically meaningful and exceedingly simple in concept and in implementation. It is shown that with currently available commercial equipment one might expect to detect a threshold value for the component of velocity of the earth's motion with respect to absolute space in the equatorial plane of approximately 10 km/s, which greatly exceeds the velocity resolution required to detect the motion of the solar system with respect to the center of the galaxy.
49 CFR 214.337 - On-track safety procedures for lone workers.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-track equipment is not impaired by background noise, lights, precipitation, fog, passing trains, or any... performing routine inspection or minor correction may use individual train detection to establish on-track... worker retains an absolute right to use on-track safety procedures other than individual train detection...
Parallel transmission RF pulse design with strict temperature constraints.
Deniz, Cem M; Carluccio, Giuseppe; Collins, Christopher
2017-05-01
RF safety in parallel transmission (pTx) is generally ensured by imposing specific absorption rate (SAR) limits during pTx RF pulse design. There is increasing interest in using temperature to ensure safety in MRI. In this work, we present a local temperature correlation matrix formalism and apply it to impose strict constraints on maximum absolute temperature in pTx RF pulse design for head and hip regions. Electromagnetic field simulations were performed on the head and hip of virtual body models. Temperature correlation matrices were calculated for four different exposure durations ranging between 6 and 24 min using simulated fields and body-specific constants. Parallel transmission RF pulses were designed using either SAR or temperature constraints, and compared with each other and unconstrained RF pulse design in terms of excitation fidelity and safety. The use of temperature correlation matrices resulted in better excitation fidelity compared with the use of SAR in parallel transmission RF pulse design (for the 6 min exposure period, 8.8% versus 21.0% for the head and 28.0% versus 32.2% for the hip region). As RF exposure duration increases (from 6 min to 24 min), the benefit of using temperature correlation matrices on RF pulse design diminishes. However, the safety of the subject is always guaranteed (the maximum temperature was equal to 39°C). This trend was observed in both head and hip regions, where the perfusion rates are very different. Copyright © 2017 John Wiley & Sons, Ltd.
iTRAQ-Based Quantitative Proteomic Analysis of the Initiation of Head Regeneration in Planarians.
Geng, Xiaofang; Wang, Gaiping; Qin, Yanli; Zang, Xiayan; Li, Pengfei; Geng, Zhi; Xue, Deming; Dong, Zimei; Ma, Kexue; Chen, Guangwen; Xu, Cunshuan
2015-01-01
The planarian Dugesia japonica has amazing ability to regenerate a head from the anterior ends of the amputated stump with maintenance of the original anterior-posterior polarity. Although planarians present an attractive system for molecular investigation of regeneration and research has focused on clarifying the molecular mechanism of regeneration initiation in planarians at transcriptional level, but the initiation mechanism of planarian head regeneration (PHR) remains unclear at the protein level. Here, a global analysis of proteome dynamics during the early stage of PHR was performed using isobaric tags for relative and absolute quantitation (iTRAQ)-based quantitative proteomics strategy, and our data are available via ProteomeXchange with identifier PXD002100. The results showed that 162 proteins were differentially expressed at 2 h and 6 h following amputation. Furthermore, the analysis of expression patterns and functional enrichment of the differentially expressed proteins showed that proteins involved in muscle contraction, oxidation reduction and protein synthesis were up-regulated in the initiation of PHR. Moreover, ingenuity pathway analysis showed that predominant signaling pathways such as ILK, calcium, EIF2 and mTOR signaling which were associated with cell migration, cell proliferation and protein synthesis were likely to be involved in the initiation of PHR. The results for the first time demonstrated that muscle contraction and ILK signaling might played important roles in the initiation of PHR at the global protein level. The findings of this research provide a molecular basis for further unraveling the mechanism of head regeneration initiation in planarians.
den Braver, Michiel W; Vermeulen, Nico P E; Commandeur, Jan N M
2017-03-01
Modification of cellular macromolecules by reactive drug metabolites is considered to play an important role in the initiation of tissue injury by many drugs. Detection and identification of reactive intermediates is often performed by analyzing the conjugates formed after trapping by glutathione (GSH). Although sensitivity of modern mass spectrometrical methods is extremely high, absolute quantification of GSH-conjugates is critically dependent on the availability of authentic references. Although 1 H NMR is currently the method of choice for quantification of metabolites formed biosynthetically, its intrinsically low sensitivity can be a limiting factor in quantification of GSH-conjugates which generally are formed at low levels. In the present study, a simple but sensitive and generic method for absolute quantification of GSH-conjugates is presented. The method is based on quantitative alkaline hydrolysis of GSH-conjugates and subsequent quantification of glutamic acid and glycine by HPLC after precolumn derivatization with o-phthaldialdehyde/N-acetylcysteine (OPA/NAC). Because of the lower stability of the glycine OPA/NAC-derivate, quantification of the glutamic acid OPA/NAC-derivate appeared most suitable for quantification of GSH-conjugates. The novel method was used to quantify the concentrations of GSH-conjugates of diclofenac, clozapine and acetaminophen and quantification was consistent with 1 H NMR, but with a more than 100-fold lower detection limit for absolute quantification. Copyright © 2017. Published by Elsevier B.V.
Zhang, Dapeng; Long, Zhiqiang; Xue, Song; Zhang, Junge
2012-01-01
This paper studies an absolute positioning sensor for a high-speed maglev train and its fault diagnosis method. The absolute positioning sensor is an important sensor for the high-speed maglev train to accomplish its synchronous traction. It is used to calibrate the error of the relative positioning sensor which is used to provide the magnetic phase signal. On the basis of the analysis for the principle of the absolute positioning sensor, the paper describes the design of the sending and receiving coils and realizes the hardware and the software for the sensor. In order to enhance the reliability of the sensor, a support vector machine is used to recognize the fault characters, and the signal flow method is used to locate the faulty parts. The diagnosis information not only can be sent to an upper center control computer to evaluate the reliability of the sensors, but also can realize on-line diagnosis for debugging and the quick detection when the maglev train is off-line. The absolute positioning sensor we study has been used in the actual project.
Beat-to-beat heart rate estimation fusing multimodal video and sensor data
Antink, Christoph Hoog; Gao, Hanno; Brüser, Christoph; Leonhardt, Steffen
2015-01-01
Coverage and accuracy of unobtrusively measured biosignals are generally relatively low compared to clinical modalities. This can be improved by exploiting redundancies in multiple channels with methods of sensor fusion. In this paper, we demonstrate that two modalities, skin color variation and head motion, can be extracted from the video stream recorded with a webcam. Using a Bayesian approach, these signals are fused with a ballistocardiographic signal obtained from the seat of a chair with a mean absolute beat-to-beat estimation error below 25 milliseconds and an average coverage above 90% compared to an ECG reference. PMID:26309754
Beat-to-beat heart rate estimation fusing multimodal video and sensor data.
Antink, Christoph Hoog; Gao, Hanno; Brüser, Christoph; Leonhardt, Steffen
2015-08-01
Coverage and accuracy of unobtrusively measured biosignals are generally relatively low compared to clinical modalities. This can be improved by exploiting redundancies in multiple channels with methods of sensor fusion. In this paper, we demonstrate that two modalities, skin color variation and head motion, can be extracted from the video stream recorded with a webcam. Using a Bayesian approach, these signals are fused with a ballistocardiographic signal obtained from the seat of a chair with a mean absolute beat-to-beat estimation error below 25 milliseconds and an average coverage above 90% compared to an ECG reference.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elmegreen, Debra Meloy; Putko, Joseph; Dewberry, Janosz
2012-05-10
Tadpole galaxies have a giant star-forming region at the end of an elongated intensity distribution. Here we use Sloan Digital Sky Survey data to determine the ages, masses, and surface densities of the heads and tails in 14 local tadpoles selected from the Kiso and Michigan surveys of UV-bright galaxies, and we compare them to tadpoles previously studied in the Hubble Ultra Deep Field. The young stellar mass in the head scales linearly with rest-frame galaxy luminosity, ranging from {approx}10{sup 5} M{sub Sun} at galaxy absolute magnitude U = -13 mag to 10{sup 9} M{sub Sun} at U = -20more » mag. The corresponding head surface density increases from several M {sub Sun} pc{sup -2} locally to 10-100 M{sub Sun} pc{sup -2} at high redshift, and the star formation rate (SFR) per unit area in the head increases from {approx}0.01 M{sub Sun} yr{sup -1} kpc{sup -2} locally to {approx}1 M{sub Sun} yr{sup -1} kpc{sup -2} at high z. These local values are normal for star-forming regions, and the increases with redshift are consistent with other cosmological SFRs, most likely reflecting an increase in gas abundance. The tails in the local sample look like bulge-free galaxy disks. Their photometric ages decrease from several Gyr to several hundred Myr with increasing z, and their surface densities are more constant than the surface densities of the heads. The far-outer intensity profiles in the local sample are symmetric and exponential. We suggest that most local tadpoles are bulge-free galaxy disks with lopsided star formation, perhaps from environmental effects such as ram pressure or disk impacts, or from a Jeans length comparable to half the disk size.« less
Pomeroy, Emma; Wells, Jonathan C K; Cole, Tim J; O'Callaghan, Michael; Stock, Jay T
2015-04-01
The patterns of association between maternal or paternal and neonatal phenotype may offer insight into how neonatal characteristics are shaped by evolutionary processes, such as conflicting parental interests in fetal investment and obstetric constraints. Paternal interests are theoretically served by maximizing fetal growth, and maternal interests by managing investment in current and future offspring, but whether paternal and maternal influences act on different components of overall size is unknown. We tested whether parents' prepregnancy height and body mass index (BMI) were related to neonatal anthropometry (birthweight, head circumference, absolute and proportional limb segment and trunk lengths, subcutaneous fat) among 1,041 Australian neonates using stepwise linear regression. Maternal and paternal height and maternal BMI were associated with birthweight. Paternal height related to offspring forearm and lower leg lengths, maternal height and BMI to neonatal head circumference, and maternal BMI to offspring adiposity. Principal components analysis identified three components of variability reflecting neonatal "head and trunk skeletal size," "adiposity," and "limb lengths." Regression analyses of the component scores supported the associations of head and trunk size or adiposity with maternal anthropometry, and limb lengths with paternal anthropometry. Our results suggest that while neonatal fatness reflects environmental conditions (maternal physiology), head circumference and limb and trunk lengths show differing associations with parental anthropometry. These patterns may reflect genetics, parental imprinting and environmental influences in a manner consistent with parental conflicts of interest. Paternal height may relate to neonatal limb length as a means of increasing fetal growth without exacerbating the risk of obstetric complications. © 2014 The Authors American Journal of Physical Anthropology Published by Wiley Periodicals, Inc.
Pomeroy, Emma; Wells, Jonathan CK; Cole, Tim J; O'Callaghan, Michael; Stock, Jay T
2015-01-01
The patterns of association between maternal or paternal and neonatal phenotype may offer insight into how neonatal characteristics are shaped by evolutionary processes, such as conflicting parental interests in fetal investment and obstetric constraints. Paternal interests are theoretically served by maximizing fetal growth, and maternal interests by managing investment in current and future offspring, but whether paternal and maternal influences act on different components of overall size is unknown. We tested whether parents' prepregnancy height and body mass index (BMI) were related to neonatal anthropometry (birthweight, head circumference, absolute and proportional limb segment and trunk lengths, subcutaneous fat) among 1,041 Australian neonates using stepwise linear regression. Maternal and paternal height and maternal BMI were associated with birthweight. Paternal height related to offspring forearm and lower leg lengths, maternal height and BMI to neonatal head circumference, and maternal BMI to offspring adiposity. Principal components analysis identified three components of variability reflecting neonatal “head and trunk skeletal size,” “adiposity,” and “limb lengths.” Regression analyses of the component scores supported the associations of head and trunk size or adiposity with maternal anthropometry, and limb lengths with paternal anthropometry. Our results suggest that while neonatal fatness reflects environmental conditions (maternal physiology), head circumference and limb and trunk lengths show differing associations with parental anthropometry. These patterns may reflect genetics, parental imprinting and environmental influences in a manner consistent with parental conflicts of interest. Paternal height may relate to neonatal limb length as a means of increasing fetal growth without exacerbating the risk of obstetric complications. Am J Phys Anthropol 156:625–636, 2015. PMID:25502164
1985-07-01
Corporation . - P.F. Seligman . . Naval Ocean Systems Center fTW G. Vafa University of Hawaii Research Corporation P.M. Stang DEC 0 4 198 1: San Diego State...NAVFAC 032) under the Marine Environmental Quality Assessment Program. Released by Under authority of P. F. Seligman , Head S. Yamamoto, Head Marine...SEDIMENTS BY HYDRIDE DERIVATIZATION AND ATOMIC ABSORPTION DETECTION 12 PERSONAL AUJTHORWS) A. 0. Valkirs, P. F. Seligman , G. Vafa, P. M. Stang, V. Homner
Self-Referenced Fiber Optic System For Remote Methane Detection
NASA Astrophysics Data System (ADS)
Zientkiewicz, Jacek K.
1989-10-01
The paper discusses a fiber optic multisensor methane detection system matched to topology and environment of the underground mine. The system involves time domain multiplexed (TDM) methane sensors based on selective absorption of source radiation by atomic/molecular species in the gas sensing heads. A two-wavelength ratiometric approach allows simple self-referencing, cancels out errors arising from other contaminants, and improves the measurement contrast. The laboratory system consists of a high radiance LED source, multimode fiber, optical sensing head, optical bandpass filters, and involves synchronous detection with low noise photodiodes and a lock-in amplifier. Detection sensitivity versus spectral resolution of the optical filters has also been investigated and described. The system performance was evaluated and the results are presented.
NASA Astrophysics Data System (ADS)
Rotenberg, David J.
Artifacts caused by head motion are a substantial source of error in fMRI that limits its use in neuroscience research and clinical settings. Real-time scan-plane correction by optical tracking has been shown to correct slice misalignment and non-linear spin-history artifacts, however residual artifacts due to dynamic magnetic field non-uniformity may remain in the data. A recently developed correction technique, PLACE, can correct for absolute geometric distortion using the complex image data from two EPI images, with slightly shifted k-space trajectories. We present a correction approach that integrates PLACE into a real-time scan-plane update system by optical tracking, applied to a tissue-equivalent phantom undergoing complex motion and an fMRI finger tapping experiment with overt head motion to induce dynamic field non-uniformity. Experiments suggest that including volume by volume geometric distortion correction by PLACE can suppress dynamic geometric distortion artifacts in a phantom and in vivo and provide more robust activation maps.
NIR time domain diffuse optical tomography experiments on human forearm
NASA Astrophysics Data System (ADS)
Zhao, Huijuan; Gao, Feng; Tanikawa, Yukari; Homma, Kazuhiro; Yamada, Yukio
2003-07-01
To date, the applications of near infrared (NIR) diffusion optical tomography (DOT) are mostly focused on the potential of imaging woman breast, human head hemodynamics and neonatal head. For the neonates, who are suffered from ischaemia or hemorrhages in brain, bedside monitoring of the cerebral perfusion situation, e.g., the blood oxygen saturation and blood volume, is necessary for avoiding permanent injure. NIR DOT is on the promising tools because it is noninvasive, smaller in size, and moveable. Prior to achieving the ultimate goal of imaging infant brain and woman breast using DOT, in this paper, the developed methodologies are justified by imaging in vivo human forearms. The absolute absorption- and scattering-coefficient images revealed the inner structure of the forearm and the bones were clearly distinguished from the muscle. The differential images showed the changes in oxy-hemoglobin, deoxy-hemoglobin and blood volume during the hand-gripping exercises, which are consistent with the physiological process reported on literatures.
Lusaka, Zambia during SAFARI-2000: A Collection Point for Ozone Pollution
NASA Technical Reports Server (NTRS)
Thompson, Anne M.; Witte, Jacquelyn C.; Freiman, M. Tal; Phahlane, N. Agnes; Coetzee, G. J. R.; Bhartia, P. K. (Technical Monitor)
2002-01-01
In August and September, throughout south central Africa, seasonal clearing of dry vegetation and other fire-related activities lead to intense smoke haze and ozone formation. The first ozone soundings in the heart of the southern African burning region were taken at Lusaka, Zambia (155 deg S, 28 deg E) in early September 2000. Over 90 ppbv ozone was recorded at the surface (1.3 km elevation) and column tropospheric ozone was greater than 50 DU during a stagnant period. These values are much higher than concurrent measurements over Nairobi (1 deg S, 38 deg E) and Irene (25 deg S, 28 deg E, near Pretoria). The heaviest ozone pollution layer (800-500 hPa) over Lusaka is due to recirculated trans-boundary ozone. Starting out over Zambia, Angola, and Namibia, ozone heads east to the Indian Ocean, before turning back over Mozambique and Zimbabwe, heading toward Lusaka. Thus, Lusaka is a collection point for pollution, consistent with a picture of absolutely stable layers recirculating in a gyre over southern Africa.
Fried, P A; O'Connell, C M
1987-01-01
Maternal use of cigarettes, alcohol, cannabis, and caffeine was established for four time periods; prepregnancy, first trimester, third trimester and average use over pregnancy. The relationship between such usage and growth parameters of offspring followed up from birth to 12 and 24 months of age were examined. Of the soft drugs used, nicotine had the most pronounced effect. After adjustment for other relevant variables, nicotine use prior to and during pregnancy was negatively related to weight and head circumference at birth. Furthermore, third trimester nicotine use was a stronger predictor of decreased weight and head circumference at birth than was first trimester use. The results obtained are consistent with ponderal index (PI) literature suggesting a recovery of growth retardation in infants with a lowered PI. Average consumption of greater than one ounce of absolute alcohol per day was negatively related to birth weight and length. Neither cannabis nor caffeine use had a significant negative effect on any growth parameter.
NASA Astrophysics Data System (ADS)
Shea, Y.; Wielicki, B. A.; Sun-Mack, S.; Minnis, P.; Zelinka, M. D.
2016-12-01
Detecting trends in climate variables on global, decadal scales requires highly accurate, stable measurements and retrieval algorithms. Trend uncertainty depends on its magnitude, natural variability, and instrument and retrieval algorithm accuracy and stability. We applied a climate accuracy framework to quantify the impact of absolute calibration on cloud property trend uncertainty. The cloud properties studied were cloud fraction, effective temperature, optical thickness, and effective radius retrieved using the Clouds and the Earth's Radiant Energy System (CERES) Cloud Property Retrieval System, which uses Moderate-resolution Imaging Spectroradiometer measurements (MODIS). Modeling experiments from the fifth phase of the Climate Model Intercomparison Project (CMIP5) agree that net cloud feedback is likely positive but disagree regarding its magnitude, mainly due to uncertainty in shortwave cloud feedback. With the climate accuracy framework we determined the time to detect trends for instruments with various calibration accuracies. We estimated a relationship between cloud property trend uncertainty, cloud feedback, and Equilibrium Climate Sensitivity and also between effective radius trend uncertainty and aerosol indirect effect trends. The direct relationship between instrument accuracy requirements and climate model output provides the level of instrument absolute accuracy needed to reduce climate model projection uncertainty. Different cloud types have varied radiative impacts on the climate system depending on several attributes, such as their thermodynamic phase, altitude, and optical thickness. Therefore, we also conducted these studies by cloud types for a clearer understanding of instrument accuracy requirements needed to detect changes in their cloud properties. Combining this information with the radiative impact of different cloud types helps to prioritize among requirements for future satellite sensors and understanding the climate detection capabilities of existing sensors.
Groh, Claudia; Kelber, Christina; Grübel, Kornelia; Rössler, Wolfgang
2014-01-01
Hymenoptera possess voluminous mushroom bodies (MBs), brain centres associated with sensory integration, learning and memory. The mushroom body input region (calyx) is organized in distinct synaptic complexes (microglomeruli, MG) that can be quantified to analyse body size-related phenotypic plasticity of synaptic microcircuits in these small brains. Leaf-cutting ant workers (Atta vollenweideri) exhibit an enormous size polymorphism, which makes them outstanding to investigate neuronal adaptations underlying division of labour and brain miniaturization. We particularly asked how size-related division of labour in polymorphic workers is reflected in volume and total numbers of MG in olfactory calyx subregions. Whole brains of mini, media and large workers were immunolabelled with anti-synapsin antibodies, and mushroom body volumes as well as densities and absolute numbers of MG were determined by confocal imaging and three-dimensional analyses. The total brain volume and absolute volumes of olfactory mushroom body subdivisions were positively correlated with head widths, but mini workers had significantly larger MB to total brain ratios. Interestingly, the density of olfactory MG was remarkably independent from worker size. Consequently, absolute numbers of olfactory MG still were approximately three times higher in large compared with mini workers. The results show that the maximum packing density of synaptic microcircuits may represent a species-specific limit to brain miniaturization. PMID:24807257
Talavage, Thomas M; Nauman, Eric A; Breedlove, Evan L; Yoruk, Umit; Dye, Anne E; Morigaki, Katherine E; Feuer, Henry; Leverenz, Larry J
2014-02-15
Head trauma and concussion in football players have recently received considerable media attention. Postmortem evidence suggests that accrual of damage to the brain may occur with repeated blows to the head, even when the individual blows fail to produce clinical symptoms. There is an urgent need for improved detection and characterization of head trauma to reduce future injury risk and promote development of new therapies. In this study we examined neurological performance and health in the presence of head collision events in high school football players, using longitudinal measures of collision events (the HIT(™) System), neurocognitive testing (ImPACT(™)), and functional magnetic resonance imaging MRI (fMRI). Longitudinal assessment (including baseline) was conducted in 11 young men (ages 15-19 years) participating on the varsity and junior varsity football teams at a single high school. We expected and observed subjects in two previously described categories: (1) no clinically-diagnosed concussion and no changes in neurological behavior, and (2) clinically-diagnosed concussion with changes in neurological behavior. Additionally, we observed players in a previously undiscovered third category, who exhibited no clinically-observed symptoms associated with concussion, but who demonstrated measurable neurocognitive (primarily visual working memory) and neurophysiological (altered activation in the dorsolateral prefrontal cortex [DLPFC]) impairments. This new category was associated with significantly higher numbers of head collision events to the top-front of the head, directly above the DLPFC. The discovery of this new category suggests that more players are suffering neurological injury than are currently being detected using traditional concussion-assessment tools. These individuals are unlikely to undergo clinical evaluation, and thus may continue to participate in football-related activities, even when changes in brain physiology (and potential brain damage) are present, which will increase the risk of future neurological injury.
Descarreaux, Martin; Mayrand, Nancy; Raymond, Jean
2007-01-01
A number of recent scientific publications suggest that patients suffering from whiplash-associated disorders (WADs) exhibit sensorimotor deficits in the control of head and neck movements. The main objective of the present study was to evaluate if subjects with WADs can produce isometric neck extension and flexion forces with precision, variability, and a mode of control similar to the values of healthy subjects. A control group study with repeated measures. Neck force production parameters and neuromuscular control were measured in 17 whiplash and 14 control subjects. The experimental group included subjects who had a history of persistent neck pain or disability after a motor vehicle accident. Pain levels were assessed on a standard 100-mm visual analog pain scale at the beginning and end of the experiment. Each whiplash subject completed the neck disability index and the short-form 36 health survey (SF-36) questionnaire before the experiment. All subjects were asked to exert flexion and extension forces against a fixed head harness. Kinetic variables included time to peak force, time to peak force variability, peak force variability, and absolute error in peak force. Surface electrodes were applied bilaterally over the sternocleidomastoideus and paraspinal muscles. Electromyography (EMG)-dependent variables included EMG burst duration and amplitude using numerical integrated techniques. The average time to peak force was significantly longer for whiplash subjects than for the healthy controls. A significant increase in peak force variability was also observed in the whiplash group, and no group differences were noted for absolute error. Heightened muscular activity was seen in both paraspinal muscles, even though it only reached statistical significance for the left paraspinal muscle. Our results show that the whiplash subjects involved in the study were able to produce isometric forces with spatial precision similar to healthy controls using a motor strategy in which the time to peak force is increased. This trade-off between spatial precision and time to peak force probably reflects an adaptation aimed at limiting pain and further injuries.
Determination of simple thresholds for accelerometry-based parameters for fall detection.
Kangas, Maarit; Konttila, Antti; Winblad, Ilkka; Jämsä, Timo
2007-01-01
The increasing population of elderly people is mainly living in a home-dwelling environment and needs applications to support their independency and safety. Falls are one of the major health risks that affect the quality of life among older adults. Body attached accelerometers have been used to detect falls. The placement of the accelerometric sensor as well as the fall detection algorithms are still under investigation. The aim of the present pilot study was to determine acceleration thresholds for fall detection, using triaxial accelerometric measurements at the waist, wrist, and head. Intentional falls (forward, backward, and lateral) and activities of daily living (ADL) were performed by two voluntary subjects. The results showed that measurements from the waist and head have potential to distinguish between falls and ADL. Especially, when the simple threshold-based detection was combined with posture detection after the fall, the sensitivity and specificity of fall detection were up to 100 %. On the contrary, the wrist did not appear to be an optimal site for fall detection.
DiBona, G F; Johns, E J; Osborn, J L
1981-01-01
1. Anaesthetized dogs were subjected to two 15 min periods of 60 degrees head-up tilt. Renal perfusion pressure was regulated to minimize changes during tilting. 2. In both intact and vagotomized animals there was a fall in systemic arterial pressure and a rise in heart rate. In both intact and vagotomized animals glomerular filtration rate fell slightly during the first tilt but remained unchanged in the second tilt period. Renal blood flow was unchanged throughout. 3. Both absolute and fractional excretions of sodium were reduced in intact animals subjected to the two consecutive periods of tilt. Following vagotomy these responses were as large as those observed in intact animals. 4. Tilting caused an increase in renin secretion from the kidney in both tilting periods to which the intact animals were subjected. In the vagotomized animals the increase in renin secretion was as large as that observed in intact animals. 5. The results of the present study show that, under the experimental conditions used, vagal afferent activity had no measurable effect on the decreases in sodium excretion or increases in renin secretion mediated by the renal nerves during short periods of 60 degrees head-up tilt. PMID:7033504
Shibata, Kaito; Naito, Takafumi; Okamura, Jun; Hosokawa, Seiji; Mineta, Hiroyuki; Kawakami, Junichi
2017-11-30
Proteomic approaches using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) without an immunopurification technique have not been applied to the determination of serum cetuximab. This study developed a simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum and applied it to clinical settings. Surrogate peptides derived from cetuximab digests were selected using a Fourier transform mass spectrometer. Reduced-alkylated serum cetuximab without immunopurification was digested for 20minutes using immobilized trypsin, and the digestion products were purified by solid-phase extraction. The LC-MS/MS was run in positive ion multiple reaction monitoring mode. This method was applied to the determination of serum samples in head and neck cancer patients treated with cetuximab. The chromatographic run time was 10minutes and no peaks interfering with surrogate peptides in serum digestion products were observed. The calibration curve of absolute cetuximab in serum was linear over the concentration range of 4-200μg/mL. The lower limit of quantification of cetuximab in human serum was 4μg/mL. The intra-assay and inter-assay precision and accuracy were less than 13.2% and 88.0-100.7%, respectively. The serum concentration range of cetuximab was 19-140μg/mL in patients. The serum cetuximab concentrations in LC-MS/MS were correlated with those in ELISA (r=0.899, P <0.01) and the mean bias was 1.5% in cancer patients. In conclusion, the present simple and rapid method with acceptable analytical performance can be helpful for evaluating the absolute concentration of serum cetuximab in clinical settings. Copyright © 2017 Elsevier B.V. All rights reserved.
Non-invasive Continuous Monitoring of Cerebral Edema Using Portable Microwave Based System
NASA Astrophysics Data System (ADS)
Jiang, Yuhao; Zhao, Minji; Wang, Huiqian; Li, Guoquan
2018-01-01
A portable non-invasive head detecting system based on microwave technology was developed for evaluation of cerebral edema change inside human brain. Real-time monitoring of cerebral edema in the brain helps the clinician to assess medical condition and treatment. In this work, a microwave signal was transmitted and coupled into an open-end circular waveguide sensor, incident on a 3D printed head phantom, and reflected back to receiver. Theoretically, the operation of this instrument depends on the conductivity contrast between cerebral edema and healthy brain tissues. The efficacy of the proposed detecting system is verified using 3D printed anatomically and dielectrically realistic human head phantoms with simulated cerebral edema targets with different size. Changes in the amplitude of time domain result were shown to be induced by the expansion or decrease of the edema volume. The eventual goal of this proposed head evaluating system is use in the hospital as an effective real-time monitoring tool.
Comparing Immunohistologic and Demographic Variables of Head and Neck Squamous Cell Carcinoma
2015-06-01
HPV 16 and 18 which have a well-established association with cervical cancers . However, HPV 16 accounts for the majority ofHPV...These cancers are now subdivided into HPV associated ( HPV - SCC) and non- HPV associated squamous cell (SCC) carcinomas. HPV -SCG is a distinct entity... cell carcinomas. Laryngoscope 2009; 119(8): 1542-1549. 13. Venuti A, Paolini F. HPV detection methods in head and neck cancer . Head Neck
Visual-Vestibular Conflict Detection Depends on Fixation.
Garzorz, Isabelle T; MacNeilage, Paul R
2017-09-25
Visual and vestibular signals are the primary sources of sensory information for self-motion. Conflict among these signals can be seriously debilitating, resulting in vertigo [1], inappropriate postural responses [2], and motion, simulator, or cyber sickness [3-8]. Despite this significance, the mechanisms mediating conflict detection are poorly understood. Here we model conflict detection simply as crossmodal discrimination with benchmark performance limited by variabilities of the signals being compared. In a series of psychophysical experiments conducted in a virtual reality motion simulator, we measure these variabilities and assess conflict detection relative to this benchmark. We also examine the impact of eye movements on visual-vestibular conflict detection. In one condition, observers fixate a point that is stationary in the simulated visual environment by rotating the eyes opposite head rotation, thereby nulling retinal image motion. In another condition, eye movement is artificially minimized via fixation of a head-fixed fixation point, thereby maximizing retinal image motion. Visual-vestibular integration performance is also measured, similar to previous studies [9-12]. We observe that there is a tradeoff between integration and conflict detection that is mediated by eye movements. Minimizing eye movements by fixating a head-fixed target leads to optimal integration but highly impaired conflict detection. Minimizing retinal motion by fixating a scene-fixed target improves conflict detection at the cost of impaired integration performance. The common tendency to fixate scene-fixed targets during self-motion [13] may indicate that conflict detection is typically a higher priority than the increase in precision of self-motion estimation that is obtained through integration. Copyright © 2017 Elsevier Ltd. All rights reserved.
An attempt to detect lameness in galloping horses by use of body-mounted inertial sensors.
Lopes, Marco A F; Dearo, Antonio C O; Lee, Allen; Reed, Shannon K; Kramer, Joanne; Pai, P Frank; Yonezawa, Yoshiharu; Maki, Hiromitchi; Morgan, Terry L; Wilson, David A; Keegan, Kevin G
2016-10-01
OBJECTIVE To evaluate head, pelvic, and limb movement to detect lameness in galloping horses. ANIMALS 12 Thoroughbreds. PROCEDURES Movement data were collected with inertial sensors mounted on the head, pelvis, and limbs of horses trotting and galloping in a straight line before and after induction of forelimb and hind limb lameness by use of sole pressure. Successful induction of lameness was determined by measurement of asymmetric vertical head and pelvic movement during trotting. Differences in gallop strides before and after induction of lameness were evaluated with paired-sample statistical analysis and neural network training and testing. Variables included maximum, minimum, range, and time indices of vertical head and pelvic acceleration, head rotation in the sagittal plane, pelvic rotation in the frontal plane, limb contact intervals, stride durations, and limb lead preference. Difference between median standardized gallop strides for each limb lead before and after induction of lameness was calculated as the sum of squared differences at each time index and assessed with a 2-way ANOVA. RESULTS Head and pelvic acceleration and rotation, limb timing, stride duration measurements, and limb lead preference during galloping were not significantly different before and after induction of lameness in the forelimb or hind limb. Differences between limb leads before induction of lameness were similar to or greater than differences within limb leads before and after lameness induction. CONCLUSIONS AND CLINICAL RELEVANCE Galloping horses maintained asymmetry of head, pelvic, and limb motion between limb leads that was unrelated to lameness.
Molecular Survey of Head and Body Lice, Pediculus humanus, in France.
Candy, Kerdalidec; Amanzougaghene, Nadia; Izri, Arezki; Brun, Sophie; Durand, Rémy; Louni, Meriem; Raoult, Didier; Fenollar, Florence; Mediannikov, Oleg
2018-05-01
Human lice, Pediculus humanus, are obligate blood-sucking parasites. Phylogenetically, they belong to several mitochondrial clades exhibiting some geographic differences. Currently, the body louse is the only recognized disease vector, with the head louse being proposed as an additional vector. In this article, we study the genetic diversity of head and body lice collected from Bobigny, a town located close to Paris (France), and look for louse-borne pathogens. By amplifying and sequencing the cytb gene, we confirmed the presence of clades A and B in France. Besides, by amplifying and sequencing both cytb and cox1 gene, we reported, for the first time, the presence of clade E, which has thus far only been found in lice from West Africa. DNA from Bartonella quintana was detected in 16.7% of body lice from homeless individuals, but in none of the head lice collected from 47 families. Acinetobacter DNA was detected in 11.5% of head lice belonging to all three clades and 29.1% of body lice. Six species of Acinetobacter were identified, including two potential new ones. Acinetobacter baumannii was the most prevalent, followed by Candidatus Acinetobacter Bobigny-1, Acinetobacter calcoaceticus, Acinetobacter nosocomialis, Acinetobacter junii, and Candidatus Acinetobacter Bobigny-2. Body lice were found to be infected only with A. baumannii. These findings show for the first time, the presence of clade E head lice in France. This study is also the first to report the presence of DNAs of several species of Acinetobacter in human head lice in France.
Single cell digital polymerase chain reaction on self-priming compartmentalization chip
Zhu, Qiangyuan; Qiu, Lin; Xu, Yanan; Li, Guang; Mu, Ying
2017-01-01
Single cell analysis provides a new framework for understanding biology and disease, however, an absolute quantification of single cell gene expression still faces many challenges. Microfluidic digital polymerase chain reaction (PCR) provides a unique method to absolutely quantify the single cell gene expression, but only limited devices are developed to analyze a single cell with detection variation. This paper describes a self-priming compartmentalization (SPC) microfluidic digital polymerase chain reaction chip being capable of performing single molecule amplification from single cell. The chip can be used to detect four single cells simultaneously with 85% of sample digitization. With the optimized protocol for the SPC chip, we first tested the ability, precision, and sensitivity of our SPC digital PCR chip by assessing β-actin DNA gene expression in 1, 10, 100, and 1000 cells. And the reproducibility of the SPC chip is evaluated by testing 18S rRNA of single cells with 1.6%–4.6% of coefficient of variation. At last, by detecting the lung cancer related genes, PLAU gene expression of A549 cells at the single cell level, the single cell heterogeneity was demonstrated. So, with the power-free, valve-free SPC chip, the gene copy number of single cells can be quantified absolutely with higher sensitivity, reduced labor time, and reagent. We expect that this chip will enable new studies for biology and disease. PMID:28191267
Single cell digital polymerase chain reaction on self-priming compartmentalization chip.
Zhu, Qiangyuan; Qiu, Lin; Xu, Yanan; Li, Guang; Mu, Ying
2017-01-01
Single cell analysis provides a new framework for understanding biology and disease, however, an absolute quantification of single cell gene expression still faces many challenges. Microfluidic digital polymerase chain reaction (PCR) provides a unique method to absolutely quantify the single cell gene expression, but only limited devices are developed to analyze a single cell with detection variation. This paper describes a self-priming compartmentalization (SPC) microfluidic digital polymerase chain reaction chip being capable of performing single molecule amplification from single cell. The chip can be used to detect four single cells simultaneously with 85% of sample digitization. With the optimized protocol for the SPC chip, we first tested the ability, precision, and sensitivity of our SPC digital PCR chip by assessing β-actin DNA gene expression in 1, 10, 100, and 1000 cells. And the reproducibility of the SPC chip is evaluated by testing 18S rRNA of single cells with 1.6%-4.6% of coefficient of variation. At last, by detecting the lung cancer related genes, PLAU gene expression of A549 cells at the single cell level, the single cell heterogeneity was demonstrated. So, with the power-free, valve-free SPC chip, the gene copy number of single cells can be quantified absolutely with higher sensitivity, reduced labor time, and reagent. We expect that this chip will enable new studies for biology and disease.
Absolute and angular efficiencies of a microchannel-plate position-sensitive detector
NASA Technical Reports Server (NTRS)
Gao, R. S.; Gibner, P. S.; Newman, J. H.; Smith, K. A.; Stebbings, R. F.
1984-01-01
This paper presents a characterization of a commercially available position-sensitive detector of energetic ions and neutrals. The detector consists of two microchannel plates followed by a resistive position-encoding anode. The work includes measurement of absolute efficiencies of H(+), He(+), and O(+) ions in the energy range between 250 and 5000 eV, measurement of relative detection efficiencies as a function of particle impact angle, and a simple method for accurate measurement of the time at which a particle strikes the detector.
Head Pose Estimation Using Multilinear Subspace Analysis for Robot Human Awareness
NASA Technical Reports Server (NTRS)
Ivanov, Tonislav; Matthies, Larry; Vasilescu, M. Alex O.
2009-01-01
Mobile robots, operating in unconstrained indoor and outdoor environments, would benefit in many ways from perception of the human awareness around them. Knowledge of people's head pose and gaze directions would enable the robot to deduce which people are aware of the its presence, and to predict future motions of the people for better path planning. To make such inferences, requires estimating head pose on facial images that are combination of multiple varying factors, such as identity, appearance, head pose, and illumination. By applying multilinear algebra, the algebra of higher-order tensors, we can separate these factors and estimate head pose regardless of subject's identity or image conditions. Furthermore, we can automatically handle uncertainty in the size of the face and its location. We demonstrate a pipeline of on-the-move detection of pedestrians with a robot stereo vision system, segmentation of the head, and head pose estimation in cluttered urban street scenes.
Population trends of binary near-Earth asteroids based on radar and lightcurves observations
NASA Astrophysics Data System (ADS)
Brozovic, Marina; Benner, Lance A. M.; Naidu, Shantanu P.; Taylor, Patrick A.; Busch, Michael W.; Margot, Jean-Luc; Nolan, Michael C.; Howell, Ellen S.; Springmann, Alessondra; Giorgini, Jon D.; Shepard, Michael K.; Magri, Christopher; Richardson, James E.; Rivera-Valentin, Edgard G.; Rodriguez-Ford, Linda A.; Zambrano Marin, Luisa Fernanda
2016-10-01
The Arecibo and Goldstone planetary radars are invaluable instruments for the discovery and characterization of binary and triple asteroids in the near-Earth asteroid (NEA) population. To date, 41 out of 56 known binaries and triples (~73% of the objects) have been discovered by radar and 49 of these multiple systems have been detected by radar. Their absolute magnitudes range from 12.4 for (1866) Sisyphus to 22.6 for 2015 TD144 and have a mean and rms dispersion of 18.1+-2.0. There is a pronounced decrease in the abundance of binaries for absolute magnitudes H>20. One of the smallest binaries, 1994 CJ1, with an absolute magnitude H=21.4, is also the most accessible binary for a spacecraft rendezvous. Among 365 NEAs with H<22 (corresponding to diameters larger than ~ 140 m) detected by radar since 1999, ~13% have at least one companion. Two triple systems are known, (15391) 2001 SN263 and (136617) 1994 CC, but this is probably an underestimate due to low signal to noise ratios (SNRs) for many of the binary radar detections. Taxonomic classes have been reported for 41 out of 56 currently known multiple systems and some trends are starting to emerge: at least 50% of multiple asteroid systems are S, Sq, Q, or Sk, and at least 20% are optically dark (C, B, P, or U). Thirteen V-class NEAs have been observed by radar and six of them are binaries. Curiously, a comparable number of E-class objects have been detected by radar, but none is known to be a binary.
Jarnuczak, Andrew F; Lee, Dave C H; Lawless, Craig; Holman, Stephen W; Eyers, Claire E; Hubbard, Simon J
2016-09-02
Quantitative mass spectrometry-based proteomics of complex biological samples remains challenging in part due to the variability and charge competition arising during electrospray ionization (ESI) of peptides and the subsequent transfer and detection of ions. These issues preclude direct quantification from signal intensity alone in the absence of a standard. A deeper understanding of the governing principles of peptide ionization and exploitation of the inherent ionization and detection parameters of individual peptides is thus of great value. Here, using the yeast proteome as a model system, we establish the concept of peptide F-factor as a measure of detectability, closely related to ionization efficiency. F-factor is calculated by normalizing peptide precursor ion intensity by absolute abundance of the parent protein. We investigated F-factor characteristics in different shotgun proteomics experiments, including across multiple ESI-based LC-MS platforms. We show that F-factors mirror previously observed physicochemical predictors as peptide detectability but demonstrate a nonlinear relationship between hydrophobicity and peptide detectability. Similarly, we use F-factors to show how peptide ion coelution adversely affects detectability and ionization. We suggest that F-factors have great utility for understanding peptide detectability and gas-phase ion chemistry in complex peptide mixtures, selection of surrogate peptides in targeted MS studies, and for calibration of peptide ion signal in label-free workflows. Data are available via ProteomeXchange with identifier PXD003472.
NASA Technical Reports Server (NTRS)
Liu, Tsuen-Hsi (Inventor); Psaltis, Demetri (Inventor); Mok, Fai H. (Inventor); Zhou, Gan (Inventor)
2005-01-01
An optical memory for storing and/or reading data on an optical disk. The optical disk incorporates a material in which holographic gratings can be created, and subsequently detected, at plural locations within the disk by an electro-optical head. Creation and detection of holographic gratings with variable diffraction efficiency is possible with the electro-optical head. Multiple holographic gratings can also be created at each one of the plural locations via a beam of light which has a different wavelength or point of focus. These data elements can be read by the electro-optical head using a beam of light sequentially varied in wavelength or point of focus to correspond to the multiple holographic gratings to be recorded.
A new technique to expose the hypopharyngeal space: The modified Killian's method.
Sakai, Akihiro; Okami, Kenji; Sugimoto, Ryousuke; Ebisumoto, Koji; Yamamoto, Hikaru; Maki, Daisuke; Saito, Kosuke; Iida, Masahiro
2014-04-01
Recent remarkable progress in endoscopic technology has enabled the detection of superficial cancers that were undetectable in the past. However, even though advanced endoscopic technology can detect early lesions, it is useless unless it can provide wide exposure of an area. By modifying the Killian position, it is possible to observe a wider range of the hypopharyngeal space than is possible with conventional head positions. We report a revolutionary method that uses a new head position to widely open the hypopharynx. The technique is named "the Modified Killian's method." The patient is initially placed in the Killian position and then bent further forward from the original position (i.e., the modified Killian position). While in this position, the patient's head is turned and the Valsalva maneuver is applied. These additional maneuvers constitute the Modified Killian's method and widely expands the hypopharyngeal space. The conventional head position cannot open the hypopharyngeal space sufficiently; however, the Modified Killian's method opens the hypopharyngeal space very widely. The Modified Killian's method enables observation of the entire circumference of the hypopharyngeal space and the cervical esophageal entry. The Modified Killian's method may become an indispensable technique for observing the hypopharynx and detecting hypopharyngeal cancers. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Noise Reduction in Brainwaves by Using Both EEG Signals and Frontal Viewing Camera Images
Bang, Jae Won; Choi, Jong-Suk; Park, Kang Ryoung
2013-01-01
Electroencephalogram (EEG)-based brain-computer interfaces (BCIs) have been used in various applications, including human–computer interfaces, diagnosis of brain diseases, and measurement of cognitive status. However, EEG signals can be contaminated with noise caused by user's head movements. Therefore, we propose a new method that combines an EEG acquisition device and a frontal viewing camera to isolate and exclude the sections of EEG data containing these noises. This method is novel in the following three ways. First, we compare the accuracies of detecting head movements based on the features of EEG signals in the frequency and time domains and on the motion features of images captured by the frontal viewing camera. Second, the features of EEG signals in the frequency domain and the motion features captured by the frontal viewing camera are selected as optimal ones. The dimension reduction of the features and feature selection are performed using linear discriminant analysis. Third, the combined features are used as inputs to support vector machine (SVM), which improves the accuracy in detecting head movements. The experimental results show that the proposed method can detect head movements with an average error rate of approximately 3.22%, which is smaller than that of other methods. PMID:23669713
Miyashita, Theresa L; Diakogeorgiou, Eleni; Marrie, Kaitlyn
Investigation into the effect of cumulative subconcussive head impacts has yielded various results in the literature, with many supporting a link to neurological deficits. Little research has been conducted on men's lacrosse and associated balance deficits from head impacts. (1) Athletes will commit more errors on the postseason Balance Error Scoring System (BESS) test. (2) There will be a positive correlation to change in BESS scores and head impact exposure data. Prospective longitudinal study. Level 3. Thirty-four Division I men's lacrosse players (age, 19.59 ± 1.42 years) wore helmets instrumented with a sensor to collect head impact exposure data over the course of a competitive season. Players completed a BESS test at the start and end of the competitive season. The number of errors from pre- to postseason increased during the double-leg stance on foam ( P < 0.001), tandem stance on foam ( P = 0.009), total number of errors on a firm surface ( P = 0.042), and total number of errors on a foam surface ( P = 0.007). There were significant correlations only between the total errors on a foam surface and linear acceleration ( P = 0.038, r = 0.36), head injury criteria ( P = 0.024, r = 0.39), and Gadd Severity Index scores ( P = 0.031, r = 0.37). Changes in the total number of errors on a foam surface may be considered a sensitive measure to detect balance deficits associated with cumulative subconcussive head impacts sustained over the course of 1 lacrosse season, as measured by average linear acceleration, head injury criteria, and Gadd Severity Index scores. If there is microtrauma to the vestibular system due to repetitive subconcussive impacts, only an assessment that highly stresses the vestibular system may be able to detect these changes. Cumulative subconcussive impacts may result in neurocognitive dysfunction, including balance deficits, which are associated with an increased risk for injury. The development of a strategy to reduce total number of head impacts may curb the associated sequelae. Incorporation of a modified BESS test, firm surface only, may not be recommended as it may not detect changes due to repetitive impacts over the course of a competitive season.
Microcephaly: general considerations and aids to nosology.
Opitz, J M; Holt, M C
1990-01-01
Microcephaly is defined as an occipito-frontal head circumference (OFC) 2 or more standard deviations below the mean for age and sex using the new Roche et al. [Pediatrics 1987;79:706-712] charts, and corrected for parental OFC by the method of Weaver and Christian [J Pediatr 1980;96:990-994]. "Relative" microcephaly, i.e., a small head on a small child, may be associated with a much better intellectual prognosis than absolute microcephaly, although the average IQ of children with absolute microcephaly ascertained in a normal school system is normal when compared with that of appropriate control children. "Primary" microcephaly means an abnormal OFC at birth (corrected for gestational age and length), and "secondary" microcephaly a normal birth OFC with later, acquired microcephaly due to deceleration of brain growth reflecting infection, trauma, intoxication, metabolic disease, the Rett syndrome, or a true CNS degenerative disease. Some cases of syndromal microcephaly may be associated with normal intelligence including some "primordial dwarfs," children with Dubowitz syndrome, FAS, mild SC-Roberts syndrome, and an occasional Brachmann-de Lange individual. The nosology of (syndromal) microcephaly is extraordinarily complex and requires the assistance of special library resources and information retrieval expertise. At a minimum, it requires McKusick's Catalog of Mendelian Inheritance in Man (MIM); however, we find that our work is greatly enhanced by recently developed electronic databases such as MIM-online (OMIM), POSSUM, SYNDROME, and MEDLINE, as well. Three groups of syndromal and non-syndromal microcephaly are discussed selectively in order to illustrate the marvels of pleiotropy in human development and its abnormalities and the difficulties encountered in splitting and lumping entities with overlapping manifestations.
Mortensen, Martin B; Afzal, Shoaib; Nordestgaard, Børge G; Falk, Erling
2015-12-22
Guidelines recommend initiating primary prevention for atherosclerotic cardiovascular disease (ASCVD) with statins based on absolute ASCVD risk assessment. Recently, alternative trial-based and hybrid approaches were suggested for statin treatment eligibility. This study compared these approaches in a direct head-to-head fashion in a contemporary population. The study used the CGPS (Copenhagen General Population Study) with 37,892 subjects aged 40 to 75 years recruited in 2003 to 2008, all free of ASCVD, diabetes, and statin use at baseline. Among the population studied, 42% were eligible for statin therapy according to the 2013 American College of Cardiology/American Heart Association (ACC/AHA) risk assessment and cholesterol treatment guidelines approach, versus 56% with the trial-based approach and 21% with the hybrid approach. Among these statin-eligible subjects, the ASCVD event rate per 1,000 person-years was 9.8, 6.8, and 11.2, respectively. The ACC/AHA-recommended absolute risk score was well calibrated around the 7.5% 10-year ASCVD risk treatment threshold and discriminated better than the trial-based or hybrid approaches. Compared with the ACC/AHA risk-based approach, the net reclassification index for eligibility for statin therapy among 40- to 75-year-old subjects from the CGPS was -0.21 for the trial-based approach and -0.13 for the hybrid approach. The clinical performance of the ACC/AHA risk-based approach for primary prevention of ASCVD with statins was superior to the trial-based and hybrid approaches. Our results indicate that the ACC/AHA guidelines will prevent more ASCVD events than the trial-based and hybrid approaches, while treating fewer people compared with the trial-based approach. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Vertical gaze angle: absolute height-in-scene information for the programming of prehension.
Gardner, P L; Mon-Williams, M
2001-02-01
One possible source of information regarding the distance of a fixated target is provided by the height of the object within the visual scene. It is accepted that this cue can provide ordinal information, but generally it has been assumed that the nervous system cannot extract "absolute" information from height-in-scene. In order to use height-in-scene, the nervous system would need to be sensitive to ocular position with respect to the head and to head orientation with respect to the shoulders (i.e. vertical gaze angle or VGA). We used a perturbation technique to establish whether the nervous system uses vertical gaze angle as a distance cue. Vertical gaze angle was perturbed using ophthalmic prisms with the base oriented either up or down. In experiment 1, participants were required to carry out an open-loop pointing task whilst wearing: (1) no prisms; (2) a base-up prism; or (3) a base-down prism. In experiment 2, the participants reached to grasp an object under closed-loop viewing conditions whilst wearing: (1) no prisms; (2) a base-up prism; or (3) a base-down prism. Experiment 1 and 2 provided clear evidence that the human nervous system uses vertical gaze angle as a distance cue. It was found that the weighting attached to VGA decreased with increasing target distance. The weighting attached to VGA was also affected by the discrepancy between the height of the target, as specified by all other distance cues, and the height indicated by the initial estimate of the position of the supporting surface. We conclude by considering the use of height-in-scene information in the perception of surface slant and highlight some of the complexities that must be involved in the computation of environmental layout.
Dixon, Stephanie N.; Kuwornu, Paul John; Dev, Varun K.; Montero-Odasso, Manuel; Burneo, Jorge; Garg, Amit X.
2018-01-01
Gabapentin is an effective treatment for chronic neuropathic pain but may cause dizziness, drowsiness, and confusion in some older adults. The goal of this study was to assess the association between gabapentin dosing and adverse outcomes by obtaining estimates of the 30-day risk of hospitalization with altered mental status and mortality in older adults (mean age 76 years) in Ontario, Canada initiated on high dose (>600 mg/day; n = 34,159) compared to low dose (≤600 mg/day; n = 76,025) oral gabapentin in routine outpatient care. A population-based, retrospective cohort study assessing new gabapentin use between 2002 to 2014 was conducted. The primary outcome was 30-day hospitalization with an urgent head computed tomography (CT) scan in the absence of evidence of stroke (a proxy for altered mental status). The secondary outcome was 30-day all-cause mortality. The baseline characteristics measured in the two dose groups were similar. Initiation of a high versus low dose of gabapentin was associated with a higher risk of hospitalization with head CT scan (1.27% vs. 1.06%, absolute risk difference 0.21%, adjusted relative risk 1.29 [95% CI 1.14 to 1.46], number needed to treat 477) but not a statistically significant higher risk of mortality (1.25% vs. 1.16%, absolute risk difference of 0.09%, adjusted relative risk of 1.01 [95% CI 0.89 to 1.14]). Overall, the risk of being hospitalized with altered mental status after initiating gabapentin remains low, but may be reduced through the judicious use of gabapentin, use of the lowest dose to control pain, and vigilance for early signs of altered mental status. PMID:29538407
NASA Astrophysics Data System (ADS)
Allam, A. A.; Ben-Zion, Y.
2010-12-01
We present initial results of double-difference tomographic images for the velocity structure of the San Jacinto Fault Zone (SJFZ), and related 3D forward calculations of waves in the immediate vicinity of the SJFZ. We begin by discretizing the SJFZ region with a uniform grid spacing of 500 m, extending 140 km by 80 km and down to 25 km depth. We adopt the layered 1D model of Dreger & Helmberger (1993) as a starting model for this region, and invert for 3D distributions of VP and VS with the double-difference tomography of Zhang & Thurber (2003), which makes use of absolute event-station travel times as well as relative travel times for phases from nearby event pairs. Absolute arrival times of over 78,000 P- and S-wave phase picks generated by 1127 earthquakes and recorded at 70 stations near the SJFZ are used. Only data from events with Mw greater than 2.2 are used. Though ray coverage is limited at shallow depths, we obtain relatively high-resolution images from 4 to 13 km which show a clear contrast in velocity across the NW section of the SJFZ. To the SE, in the so-called trifurcation area, the structure is more complicated, though station coverage is poorest in this region. Using the obtained image, the current event locations, and the 3D finite-difference code of Olsen (1994), we estimate the likely distributions of fault zone head waves as a tool for future deployment of instrument. We plan to conduct further studies by including more travel time picks, including those from newly-deployed stations in the SJFZ area, in order to gain a more accurate image of the velocity structure.
Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy
NASA Astrophysics Data System (ADS)
Yepes, Pablo; Adair, Antony; Grosshans, David; Mirkovic, Dragan; Poenisch, Falk; Titt, Uwe; Wang, Qianxia; Mohan, Radhe
2018-02-01
To evaluate the effect of approximations in clinical analytical calculations performed by a treatment planning system (TPS) on dosimetric indices in intensity modulated proton therapy. TPS calculated dose distributions were compared with dose distributions as estimated by Monte Carlo (MC) simulations, calculated with the fast dose calculator (FDC) a system previously benchmarked to full MC. This study analyzed a total of 525 patients for four treatment sites (brain, head-and-neck, thorax and prostate). Dosimetric indices (D02, D05, D20, D50, D95, D98, EUD and Mean Dose) and a gamma-index analysis were utilized to evaluate the differences. The gamma-index passing rates for a 3%/3 mm criterion for voxels with a dose larger than 10% of the maximum dose had a median larger than 98% for all sites. The median difference for all dosimetric indices for target volumes was less than 2% for all cases. However, differences for target volumes as large as 10% were found for 2% of the thoracic patients. For organs at risk (OARs), the median absolute dose difference was smaller than 2 Gy for all indices and cohorts. However, absolute dose differences as large as 10 Gy were found for some small volume organs in brain and head-and-neck patients. This analysis concludes that for a fraction of the patients studied, TPS may overestimate the dose in the target by as much as 10%, while for some OARs the dose could be underestimated by as much as 10 Gy. Monte Carlo dose calculations may be needed to ensure more accurate dose computations to improve target coverage and sparing of OARs in proton therapy.
Hitchman, Sean M.; Mather, Martha E.; Smith, Joseph M.; Fencl, Jane S.
2018-01-01
Conserving native biodiversity depends on restoring functional habitats in the face of human-induced disturbances. Low-head dams are a ubiquitous human impact that degrades aquatic ecosystems worldwide. To improve our understanding of how low-head dams impact habitat and associated biodiversity, our research examined complex interactions among three spheres of the total environment. i.e., how low-head dams (anthroposphere) affect aquatic habitat (hydrosphere), and native biodiversity (biosphere) in streams and rivers. Creation of lake-like habitats upstream of low-head dams is a well-documented major impact of dams. Alterations downstream of low head dams also have important consequences, but these downstream dam effects are more challenging to detect. In a multidisciplinary field study at five dammed and five undammed sites within the Neosho River basin, KS, we tested hypotheses about two types of habitat sampling (transect and mosaic) and two types of statistical analyses (analysis of covariance and path analysis). We used fish as our example of biodiversity alteration. Our research provided three insights that can aid environmental professionals who seek to conserve and restore fish biodiversity in aquatic ecosystems threatened by human modifications. First, a mosaic approach identified habitat alterations below low-head dams (e.g. increased proportion of riffles) that were not detected using the more commonly-used transect sampling approach. Second, the habitat mosaic approach illustrated how low-head dams reduced natural variation in stream habitat. Third, path analysis, a statistical approach that tests indirect effects, showed how dams, habitat, and fish biodiversity interact. Specifically, path analysis revealed that low-head dams increased the proportion of riffle habitat below dams, and, as a result, indirectly increased fish species richness. Furthermore, the pool habitat that was created above low-head dams dramatically decreased fish species richness. As we show here, mosaic habitat sampling and path analysis can help conservation practitioners improve science-based management plans for disturbed aquatic systems worldwide.
Hitchman, Sean M; Mather, Martha E; Smith, Joseph M; Fencl, Jane S
2018-04-01
Conserving native biodiversity depends on restoring functional habitats in the face of human-induced disturbances. Low-head dams are a ubiquitous human impact that degrades aquatic ecosystems worldwide. To improve our understanding of how low-head dams impact habitat and associated biodiversity, our research examined complex interactions among three spheres of the total environment. i.e., how low-head dams (anthroposphere) affect aquatic habitat (hydrosphere), and native biodiversity (biosphere) in streams and rivers. Creation of lake-like habitats upstream of low-head dams is a well-documented major impact of dams. Alterations downstream of low head dams also have important consequences, but these downstream dam effects are more challenging to detect. In a multidisciplinary field study at five dammed and five undammed sites within the Neosho River basin, KS, we tested hypotheses about two types of habitat sampling (transect and mosaic) and two types of statistical analyses (analysis of covariance and path analysis). We used fish as our example of biodiversity alteration. Our research provided three insights that can aid environmental professionals who seek to conserve and restore fish biodiversity in aquatic ecosystems threatened by human modifications. First, a mosaic approach identified habitat alterations below low-head dams (e.g. increased proportion of riffles) that were not detected using the more commonly-used transect sampling approach. Second, the habitat mosaic approach illustrated how low-head dams reduced natural variation in stream habitat. Third, path analysis, a statistical approach that tests indirect effects, showed how dams, habitat, and fish biodiversity interact. Specifically, path analysis revealed that low-head dams increased the proportion of riffle habitat below dams, and, as a result, indirectly increased fish species richness. Furthermore, the pool habitat that was created above low-head dams dramatically decreased fish species richness. As we show here, mosaic habitat sampling and path analysis can help conservation practitioners improve science-based management plans for disturbed aquatic systems worldwide. Copyright © 2017 Elsevier B.V. All rights reserved.
Mahdavi, Mohammad Ebrahim; Pourbakht, Akram; Parand, Akram; Jalaie, Shohreh
2018-03-01
Evaluation of dichotic listening to digits is a common part of many studies for diagnosis and managing auditory processing disorders in children. Previous researchers have verified test-retest relative reliability of dichotic digits results in normal children and adults. However, detecting intervention-related changes in the ear scores after dichotic listening training requires information regarding trial-to-trial typical variation of individual ear scores that is estimated using indices of absolute reliability. Previous studies have not addressed absolute reliability of dichotic listening results. To compare the results of the Persian randomized dichotic digits test (PRDDT) and its relative and absolute indices of reliability between typical achieving (TA) and learning-disabled (LD) children. A repeated measures observational study. Fifteen LD children were recruited from a previously performed study with age range of 7-12 yr. The control group consisted of 15 TA schoolchildren with age range of 8-11 yr. The Persian randomized dichotic digits test was administered on the children under free recall condition in two test sessions 7-12 days apart. We compared the average of the ear scores and ear advantage between TA and LD children. Relative indices of reliability included Pearson's correlation and intraclass correlation (ICC 2,1 ) coefficients and absolute reliability was evaluated by calculation of standard error of measurement (SEM) and minimal detectable change (MDC) using the raw ear scores. The Pearson correlation coefficient indicated that in both groups of children the ear scores of test and retest sessions were strongly and positively (greater than +0.8) correlated. The ear scores showed excellent ICC coefficient of consistency (0.78-0.82) and fair to excellent ICC coefficient of absolute agreement (0.62-0.74) in TA children and excellent ICC coefficients of consistency and absolute agreement in LD children (0.76-0.87). SEM and SEM% of the ear scores in TA children were 1.46 and 1.44% for the right ear and 4.68 and 5.47% for the left ear. SEM and SEM% of the ear scores in LD children were 4.55 and 5.88% for the right ear to 7.56 and 12.81% for the left ear. MDC and MDC% of the ear scores in TA children varied from 4.03 and 3.99% for the right ear to 12.93 and 15.13% for the left ear. MDC and MDC% of the ear scores in LD children varied from 12.57 and 16.25% for the right ear to 20.89 and 35.39% for the left ear. The LD children indicated test-retest relative reliability as high as TA children in the ear scores measured by PRDDT. However, within-subject variations of the ear scores calculated by indices of absolute reliability were considerably higher in LD children versus TA children. The results of the current study could have implications for detecting real training-related changes in the ear scores. American Academy of Audiology
A Simple Two Aircraft Conflict Resolution Algorithm
NASA Technical Reports Server (NTRS)
Chatterji, Gano B.
2006-01-01
Conflict detection and resolution methods are crucial for distributed air-ground traffic management in which the crew in, the cockpit, dispatchers in operation control centers sad and traffic controllers in the ground-based air traffic management facilities share information and participate in the traffic flow and traffic control functions. This paper describes a conflict detection, and a conflict resolution method. The conflict detection method predicts the minimum separation and the time-to-go to the closest point of approach by assuming that both the aircraft will continue to fly at their current speeds along their current headings. The conflict resolution method described here is motivated by the proportional navigation algorithm, which is often used for missile guidance during the terminal phase. It generates speed and heading commands to rotate the line-of-sight either clockwise or counter-clockwise for conflict resolution. Once the aircraft achieve a positive range-rate and no further conflict is predicted, the algorithm generates heading commands to turn back the aircraft to their nominal trajectories. The speed commands are set to the optimal pre-resolution speeds. Six numerical examples are presented to demonstrate the conflict detection, and the conflict resolution methods.
Ship heading and velocity analysis by wake detection in SAR images
NASA Astrophysics Data System (ADS)
Graziano, Maria Daniela; D'Errico, Marco; Rufino, Giancarlo
2016-11-01
With the aim of ship-route estimation, a wake detection method is developed and applied to COSMO/SkyMed and TerraSAR-X Stripmap SAR images over the Gulf of Naples, Italy. In order to mitigate the intrinsic limitations of the threshold logic, the algorithm identifies the wake features according to the hydrodynamic theory. A post-detection validation phase is performed to classify the features as real wake structures by means of merit indexes defined in the intensity domain. After wake reconstruction, ship heading is evaluated on the basis of turbulent wake direction and ship velocity is estimated by both techniques of azimuth shift and Kelvin pattern wavelength. The method is tested over 34 ship wakes identified by visual inspection in both HH and VV images at different incidence angles. For all wakes, no missed detections are reported and at least the turbulent and one narrow-V wakes are correctly identified, with ship heading successfully estimated. Also, the azimuth shift method is applied to estimate velocity for the 10 ships having route with sufficient angular separation from the satellite ground track. In one case ship velocity is successfully estimated with both methods, showing agreement within 14%.
Li, Chuanfeng; Shen, Chanjuan; Cheng, Anchun; Wang, Mingshu; Zhang, Na; Zhou, Yi; Zhu, Dekang; Jia, Renyong; Luo, Qihui; Chen, Xiaoyue
2010-01-01
An improved indirect immunoperoxidase assay (IPA) was developed to detect antigens of Duck swollen head hemorrhagic disease virus (DSHDV) in paraformaldehyde-fixed, paraffin-embedded tissues of Pekin ducks (Anas platyrhynchos). This technique used an indirect streptavidin-alkaline phosphatase labeling system with polyclonal antiserum developed against purified DSHDV antigens. Specimens from the experimentally inoculated Pekin ducks with DSHDV and archived paraffin-embedded tissues from natural cases of Duck viral swollen head hemorrhagic disease (DVSHD) were examined by clinical and histological criteria. Positive staining was most widely observed in the cytoplasm of the following organs: immune, digestive, and urinary organs, heart, lung, and trachea, which corresponded to the intracellular distribution of reovirus. The DSHDV antigens were first detected at 4 hr postinoculation in the bursa of Fabricius of infected ducks. Therefore, this method was suitable for the early diagnosis of DVSHD. Immunoperoxidase staining was not present in tissues and organs of sham-inoculated ducks (negative control). The IPA developed in the current study is a convenient, sensitive, and specific means of detecting DSHDV and is applicable to routine diagnosis, retrospective studies, and prospective studies of DSHDV infection in ducks.
Wang, Xiaolong; Liu, Yu; Wang, Xuemei; Liu, Rui; Li, Jianbo; Zhang, Guoliang; Li, Qiang; Wang, Lei; Bai, Zhigang; Zhao, Jianmin
2016-01-01
To validate the ability of (99m)Tc-Annexin V to visualize early stage of glucocorticoid-induced femoral head necrosis by comparing with (99m)Tc-MDP bone scanning. Femoral head necrosis was induced in adult New Zealand white rabbits by intramuscular injection of methylprednisolone. (99m)Tc-Annexin scintigraphy and (99m)Tc-MDP scans were performed before and 5, 6, and 8 weeks after methylprednisolone administration. Rabbits were sacrificed at various time points and conducted for TUNEL and H&E staining. All methylprednisolone treated animals developed femoral head necrosis; at 8 weeks postinjection, destruction of bone structure was evident in H&E staining, and apoptosis was confirmed by the TUNEL assay. This was matched by (99m)Tc-Annexin V images, which showed a significant increase in signal over baseline. Serial (99m)Tc-Annexin V scans revealed that increased (99m)Tc-Annexin V uptake could be observed in 5 weeks. In contrast, there was no effect on (99m)Tc-MDP signal until 8 weeks. The TUNEL assay revealed that bone cell apoptosis occurred at 5 weeks. (99m)Tc-Annexin V is superior to (99m)Tc-MDP for the early detection of glucocorticoid-induced femoral head necrosis in the rabbit and may be a better strategy for the early detection of glucocorticoid-induced femoral head necrosis in patients.
Vision Screening: A Study of 297 Head Start Children.
ERIC Educational Resources Information Center
Morse, A. R.; And Others
1987-01-01
Vision assessments were provided to 297 preschoolers in nine Head Start programs in New York State. The protocol used provided a thorough evaluation and required only seven minutes per child. Sixty-three children (21.2%) were referred for further evaluation. Visual deficits detected included decreased acuity, strabismus, astigmatism, and…
ERIC Educational Resources Information Center
Satish, Usha; Streufert, Siegfried; Eslinger, Paul J.
2006-01-01
Neuropsychological tests have limited sensitivity in identifying subtle residual cognitive impairments in patients with good medical recovery from head injury and post-concussive syndrome. Detecting and characterizing residual "real life" cognitive difficulties can be problematic for treatment purposes. This study investigated the usefulness of a…
NASA Astrophysics Data System (ADS)
Chérigier, L.; Czarnetzki, U.; Luggenhölscher, D.; Schulz-von der Gathen, V.; Döbele, H. F.
1999-01-01
Absolute atomic hydrogen densities were measured in the gaseous electronics conference reference cell parallel plate reactor by Doppler-free two-photon absorption laser induced fluorescence spectroscopy (TALIF) at λ=205 nm. The capacitively coupled radio frequency discharge was operated at 13.56 MHz in pure hydrogen under various input power and pressure conditions. The Doppler-free excitation technique with an unfocused laser beam together with imaging the fluorescence radiation by an intensified charge coupled device camera allows instantaneous spatial resolution along the radial direction. Absolute density calibration is obtained with the aid of a flow tube reactor and titration with NO2. The influence of spatial intensity inhomogenities along the laser beam and subsequent fluorescence are corrected by TALIF in xenon. A full mapping of the absolute density distribution between the electrodes was obtained. The detection limit for atomic hydrogen amounts to about 2×1018 m-3. The dissociation degree is of the order of a few percent.
VUV photoionization cross sections of HO2, H2O2, and H2CO.
Dodson, Leah G; Shen, Linhan; Savee, John D; Eddingsaas, Nathan C; Welz, Oliver; Taatjes, Craig A; Osborn, David L; Sander, Stanley P; Okumura, Mitchio
2015-02-26
The absolute vacuum ultraviolet (VUV) photoionization spectra of the hydroperoxyl radical (HO2), hydrogen peroxide (H2O2), and formaldehyde (H2CO) have been measured from their first ionization thresholds to 12.008 eV. HO2, H2O2, and H2CO were generated from the oxidation of methanol initiated by pulsed-laser-photolysis of Cl2 in a low-pressure slow flow reactor. Reactants, intermediates, and products were detected by time-resolved multiplexed synchrotron photoionization mass spectrometry. Absolute concentrations were obtained from the time-dependent photoion signals by modeling the kinetics of the methanol oxidation chemistry. Photoionization cross sections were determined at several photon energies relative to the cross section of methanol, which was in turn determined relative to that of propene. These measurements were used to place relative photoionization spectra of HO2, H2O2, and H2CO on an absolute scale, resulting in absolute photoionization spectra.
Dusenberry, Michael W; Brown, Charles K; Brewer, Kori L
2017-02-01
To construct an artificial neural network (ANN) model that can predict the presence of acute CT findings with both high sensitivity and high specificity when applied to the population of patients≥age 65years who have incurred minor head injury after a fall. An ANN was created in the Python programming language using a population of 514 patients ≥ age 65 years presenting to the ED with minor head injury after a fall. The patient dataset was divided into three parts: 60% for "training", 20% for "cross validation", and 20% for "testing". Sensitivity, specificity, positive and negative predictive values, and accuracy were determined by comparing the model's predictions to the actual correct answers for each patient. On the "cross validation" data, the model attained a sensitivity ("recall") of 100.00%, specificity of 78.95%, PPV ("precision") of 78.95%, NPV of 100.00%, and accuracy of 88.24% in detecting the presence of positive head CTs. On the "test" data, the model attained a sensitivity of 97.78%, specificity of 89.47%, PPV of 88.00%, NPV of 98.08%, and accuracy of 93.14% in detecting the presence of positive head CTs. ANNs show great potential for predicting CT findings in the population of patients ≥ 65 years of age presenting with minor head injury after a fall. As a good first step, the ANN showed comparable sensitivity, predictive values, and accuracy, with a much higher specificity than the existing decision rules in clinical usage for predicting head CTs with acute intracranial findings. Copyright © 2016 Elsevier Inc. All rights reserved.
Ibarra, Joanna; Fry, Frances; Clarice, Wickenden; Olsen, Alice; Vander Stichele, Robert H; Lapeere, Hilde; Maryan, Jenner; Franks, Andrea; Smith, Jane L
2007-10-01
The aim of this paper was to illustrate the socially inclusive nature of the Bug Busting 'whole-school approach' to head louse eradication. In the UK, Belgium and Denmark, persistent head lice in families of all socio-economic status (SES) is a problem. Since 1995 in the UK and 1998 elsewhere, an educational programme intended to teach families how to detect and treat head lice by using the Bug Busting wet combing method has been organized in some areas. Local schools lead this community strategy for prevention, known as a 'whole-school approach' (UK). We describe five studies applying the Bug Busting approach, four set in districts where some disadvantaged families live (UK and Belgium) and a fifth set in Denmark. Feasibility and consumer satisfaction are examined. One UK study analyses data on area prescribing for head lice and the impact in a deprived locality of raising the profile of Bug Busting. We find parental education in Bug Busting enables families of all SES to participate in a 'whole-school approach' to head lice. Best results are obtained when each family has a Bug Buster Kit. This provides all the combs necessary with full instructions on their use with ordinary shampoo and conditioner to detect lice, eradicate an infestation mechanically, or to check the success of any treatment. In the UK, the promotion of the Bug Busting approach is reducing primary care expenditure on treatment for head lice and professional time spent with worried parents. As a result, healthcare providers can give time to the few families who require one-to-one guidance. Incorporation of the Bug Busting approach to head lice into clinical practice in school communities contributes to sustainable control whilst overcoming health inequalities in participating families.
NASA Astrophysics Data System (ADS)
Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter
2017-11-01
Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.
NASA Astrophysics Data System (ADS)
Xu, Zhang; Reilley, Michael; Li, Run; Xu, Min
2017-06-01
We report chemometric wide-field fluorescence microscopy for imaging the spatial distribution and concentration of endogenous fluorophores in thin tissue sections. Nonnegative factorization aided by spatial diversity is used to learn both the spectral signature and the spatial distribution of endogenous fluorophores from microscopic fluorescence color images obtained under broadband excitation and detection. The absolute concentration map of individual fluorophores is derived by comparing the fluorescence from "pure" fluorophores under the identical imaging condition following the identification of the fluorescence species by its spectral signature. This method is then demonstrated by characterizing the concentration map of endogenous fluorophores (including tryptophan, elastin, nicotinamide adenine dinucleotide, and flavin adenine dinucleotide) for lung tissue specimens. The absolute concentrations of these fluorophores are all found to decrease significantly from normal, perilesional, to cancerous (squamous cell carcinoma) tissue. Discriminating tissue types using the absolute fluorophore concentration is found to be significantly more accurate than that achievable with the relative fluorescence strength. Quantification of fluorophores in terms of the absolute concentration map is also advantageous in eliminating the uncertainties due to system responses or measurement details, yielding more biologically relevant data, and simplifying the assessment of competing imaging approaches.
Zhang, Dapeng; Long, Zhiqiang; Xue, Song; Zhang, Junge
2012-01-01
This paper studies an absolute positioning sensor for a high-speed maglev train and its fault diagnosis method. The absolute positioning sensor is an important sensor for the high-speed maglev train to accomplish its synchronous traction. It is used to calibrate the error of the relative positioning sensor which is used to provide the magnetic phase signal. On the basis of the analysis for the principle of the absolute positioning sensor, the paper describes the design of the sending and receiving coils and realizes the hardware and the software for the sensor. In order to enhance the reliability of the sensor, a support vector machine is used to recognize the fault characters, and the signal flow method is used to locate the faulty parts. The diagnosis information not only can be sent to an upper center control computer to evaluate the reliability of the sensors, but also can realize on-line diagnosis for debugging and the quick detection when the maglev train is off-line. The absolute positioning sensor we study has been used in the actual project. PMID:23112619
Shi, Xueyan; Liang, Pei; Song, Dunlun; Yang, Wenling; Gao, Xiwu
2012-02-01
A novel method was developed for quantifying the levels of γ-aminobutyric acid (GABA) in the heads of houseflies (Musca domestica) and diamondback moths (Plutella xylostella (L.)), using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF). The GABA in sample was derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-LIF analysis. In total, 32 mmol/L borate buffer, at pH 9.2 and containing 5.3 mmol/L β-cyclodextrin (β-CD) and 10.4 mmol/L sodium dodecyl sulfate (SDS), was determined to be the optimum CE background electrolyte (BGE) for GABA analysis. The detection limit of GABA was 0.016 μmol/L. The relative standard deviations (RSDs) of the migration time and peak area of GABA were 1.78 and 4.93%, respectively. The average recoveries of 0.97, 3.88, and 5.83 μmol/L of GABA, each added to the head sample of housefly, ranged from 88.9 to 110.5%. This method is simple and applicable to GABA assays of the heads of insects. With this newly developed CE-LIF method, the amounts of GABA in the heads of houseflies (M. domestica) and diamondback moths (P. xylostella (L.)) were measured. The results are relevant to the understandings of some insecticides and insecticide-resistance mechanisms in pests. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
SRS-sensor 13C/12C isotops measurements for detecting Helicobacter Pylori
NASA Astrophysics Data System (ADS)
Grishkanich, Aleksandr; Chubchenko, Yan; Elizarov, Valentin; Zhevlakov, Aleksandr; Konopelko, Leonid
2018-02-01
We developed SRS-sensor 13C/12C isotops measurements detecting Helicobacter Pylori for medical diagnostics of human health. Measuring of absolute 13C/12C isotope amount ratios allows to explore the topical problems of the modern world, alcoholic beverages and tobacco, medical diagnostics of human health. SRS method is used to measure the ratio of carbon isotopes in the exhaled carbon dioxide, which is used to diagnose the human infection of Helicobacter pylori and the influence of the Helicobacter pylori bacterium on the occurrence of gastritis, gastric and duodenal ulcers. A method for the analysis of human infection with Helicobacter pylori was developed on the basis of measurements of the ratio of 13C / 12C carbon isotopes in human exhaled air with a high level of measurement accuracy. The article reviews the work in the field of provision comparability of absolute 13C/12C isotope amount ratios in the environment and food. The analysis of the technical and metrological characteristics of traditional and perspective instruments for measuring isotope ratios is presented. The provision of comparability of absolute 13C/12C isotope amount ratios is carried by gravimetrically prepared reference standards. The key features and emerging issues are discussed.
NASA Astrophysics Data System (ADS)
Nishijima, J.; Umeda, C.; Fujimitsu, Y.; Takayama, J.; Hiraga, N.; Higuchi, S.
2016-09-01
Repeat hybrid microgravity measurements were conducted around the Ogiri Geothermal Field on the western slope of Kirishima volcano, southern Kyushu, Japan. This study was undertaken to detect the short-term gravity change caused by the temporary shutdown of production and reinjection wells for regular maintenance in 2011 and 2013. Repeat microgravity measurements were taken using an A-10 absolute gravimeter (Micro-g LaCoste) and CG-5 gravimeter (Scintrex) before and after regular maintenance. Both instruments had an accuracy of 10 μgal. The gravity stations were established at 27 stations (two stations for absolute measurements and 25 stations for relative measurements). After removal of noise effects (e.g., tidal movement, precipitation, shallow groundwater level changes), the residual gravity changes were subdivided into five types of response. We detected a gravity decrease (up to 20 μgal) in the reinjection area and a gravity increase (up to 30 μgal) in the production area 1 month after the temporary shutdown. Most of the gravity stations recovered after the maintenance. The temporal density changes in the geothermal reservoir were estimated based on these gravity changes.
Ma, Hongwei; Wu, Yuanzi; Yang, Xiaoli; Liu, Xing; He, Jianan; Fu, Long; Wang, Jie; Xu, Hongke; Shi, Yi; Zhong, Renqian
2010-08-01
The key to achieve a highly sensitive and specific protein microarray assay is to prevent nonspecific protein adsorption to an "absolute" zero level because any signal amplification method will simultaneously amplify signal and noise. Here, we develop a novel solid supporting material, namely, polymer coated initiator integrated poly(dimethysiloxane) (iPDMS), which was able to achieve such "absolute" zero (i.e., below the detection limit of instrument). The implementation of this iPDMS enables practical and high-quality multiplexed enzyme-linked immunosorbent assay (ELISA) of 11 tumor markers. This iPDMS does not need any blocking steps and only require mild washing conditions. It also uses on an average 8-fold less capture antibodies compared with the mainstream nitrocellulose (NC) film. Besides saving time and materials, iPDMS achieved a limit-of-detection (LOD) as low as 19 pg mL(-1), which is sufficiently low for most current clinical diagnostic applications. We expect to see an immediate impact of this iPDMS on the realization of the great potential of protein microarray in research and practical uses such as large scale and high-throughput screening, clinical diagnosis, inspection, and quarantine.
Hartmann, Erica M.; Colquhoun, David R.; Schwab, Kellogg J.; Halden, Rolf U.
2015-01-01
Norovirus infections are one of the most prominent public health problems of microbial origin in the U.S. and other industrialized countries. Surveillance is necessary to prevent secondary infection, confirm successful cleanup after outbreaks, and track the causative agent. Quantitative mass spectrometry, based on absolute quantitation with stable-isotope labeled peptides, is a promising tool for norovirus monitoring because of its speed, sensitivity, and robustness in the face of environmental inhibitors. In the current study, we present two new methods for the detection of the norovirus genogroup I capsid protein using electrospray and matrixassisted laser desorption/ionization (MALDI) mass spectrometry. The peptide TLDPIEVPLEDVR was used to quantify norovirus-like particles down to 500 attomoles with electrospray and 100 attomoles with MALDI. With MALDI, we also demonstrate a detection limit of 1 femtomole and a quantitative dynamic range of 5 orders of magnitude in the presence of an environmental matrix effect. Due to the rapid processing time and applicability to a wide range of environmental sample types (bacterial lysate, produce, milk, soil, and groundwater), mass spectrometry-based absolute quantitation has a strong potential for use in public health and environmental sciences. PMID:25603302
NASA Astrophysics Data System (ADS)
Zheng, Chuan-Tao; Huang, Jian-Qiang; Ye, Wei-Lin; Lv, Mo; Dang, Jing-Min; Cao, Tian-Shu; Chen, Chen; Wang, Yi-Ding
2013-11-01
A portable near-infrared (NIR) CH4 detection sensor based on a distributed feedback (DFB) laser modulated at 1.654 μm is experimentally demonstrated. Intelligent temperature controller with an accuracy of -0.07 to +0.09 °C as well as a scan and modulation module generating saw-wave and cosine-wave signals are developed to drive the DFB laser, and a cost effective lock-in amplifier used to extract the second harmonic signal is integrated. Thorough experiments are carried out to obtain detection performances, including detection range, accuracy, stability and the minimum detection limit (MDL). Measurement results show that the absolute detection error relative to the standard value is less than 7% within the range of 0-100%, and the MDL is estimated to be about 11 ppm under an absorption length of 0.2 m and a noise level of 2 mVpp. Twenty-four hours monitoring on two gas samples (0.1% and 20%) indicates that the absolute errors are less than 7% and 2.5%, respectively, suggesting good long term stability. The sensor reveals competitive characteristics compared with other reported portable or handheld sensors. The developed sensor can also be used for the detection of other gases by adopting other DFB lasers with different center-wavelength using the same hardware and slightly modified software.
Krofta, Ladislav; Havelková, Linda; Urbánková, Iva; Krčmář, Michal; Hynčík, Luděk; Feyereisl, Jaroslav
2017-02-01
During vaginal delivery, the levator ani muscle (LAM) undergoes severe deformation. This stress can lead to stretch-related LAM injuries. The objective of this study was to develop a sophisticated MRI-based model to simulate changes in the LAM during vaginal delivery. A 3D finite element model of the female pelvic floor and fetal head was developed. The model geometry was based on MRI data from a nulliparous woman and 1-day-old neonate. Material parameters were estimated using uniaxial test data from the literature and by least-square minimization method. The boundary conditions reflected all anatomical constraints and supports. A simulation of vaginal delivery with regard to the cardinal movements of labor was then performed. The mean stress values in the iliococcygeus portion of the LAM during fetal head extension were 4.91-7.93 MPa. The highest stress values were induced in the pubovisceral and puborectal LAM portions (mean 27.46 MPa) at the outset of fetal head extension. The last LAM subdivision engaged in the changes in stress was the posteromedial section of the puborectal muscle. The mean stress values were 16.89 MPa at the end of fetal head extension. The LAM was elongated by nearly 2.5 times from its initial resting position. The cardinal movements of labor significantly affect the subsequent heterogeneous stress distribution in the LAM. The absolute stress values were highest in portions of the muscle that arise from the pubic bone. These areas are at the highest risk for muscle injuries with long-term complications.
Casey, D T; Frenje, J A; Gatu Johnson, M; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Knauer, J P; Meyerhofer, D D; Sangster, T C; Bionta, R M; Bleuel, D L; Döppner, T; Glenzer, S; Hartouni, E; Hatchett, S P; Le Pape, S; Ma, T; MacKinnon, A; McKernan, M A; Moran, M; Moses, E; Park, H-S; Ralph, J; Remington, B A; Smalyuk, V; Yeamans, C B; Kline, J; Kyrala, G; Chandler, G A; Leeper, R J; Ruiz, C L; Cooper, G W; Nelson, A J; Fletcher, K; Kilkenny, J; Farrell, M; Jasion, D; Paguio, R
2012-10-01
A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.
Breme, Katharina; Guillamon, Nadine; Fernandez, Xavier; Tournayre, Pascal; Brevard, Hugues; Joulain, Daniel; Berdagué, Jean Louis; Meierhenrich, Uwe J
2009-03-25
Indian cress (Tropaeolum majus L.) absolute was studied by GC-olfactometry (VIDEO-Sniff method) in order to identify odor-active aroma compounds. Because of its fruity-sulfury odor note, a compound that has never been identified in plant extracts before stood out: O,S-diethyl thiocarbonate, present at 0.1% (percentage of the total GC/FID area) in the extract. GCxGC-TOFMS allowed for a clean mass spectrum to be obtained, and isolation by preparative GC followed by NMR studies allowed its identification. Here, we report on the first detection of O,S-diethyl thiocarbonate in Indian cress absolute by GC-olfactometry/VIDEO-Sniff and on its isolation and identification. The synthesis and odor evaluation of its homologues are presented.
NASA Technical Reports Server (NTRS)
Hoge, F. E.; Swift, R. N.
1983-01-01
Airborne lidar oil spill experiments carried out to determine the practicability of the AOFSCE (absolute oil fluorescence spectral conversion efficiency) computational model are described. The results reveal that the model is suitable over a considerable range of oil film thicknesses provided the fluorescence efficiency of the oil does not approach the minimum detection sensitivity limitations of the lidar system. Separate airborne lidar experiments to demonstrate measurement of the water column Raman conversion efficiency are also conducted to ascertain the ultimate feasibility of converting such relative oil fluorescence to absolute values. Whereas the AOFSCE model is seen as highly promising, further airborne water column Raman conversion efficiency experiments with improved temporal or depth-resolved waveform calibration and software deconvolution techniques are thought necessary for a final determination of suitability.
Alarcón-Ríos, Lucía; Velo-Antón, Guillermo; Kaliontzopoulou, Antigoni
2017-04-01
The study of morphological variation among and within taxa can shed light on the evolution of phenotypic diversification. In the case of urodeles, the dorso-ventral view of the head captures most of the ontogenetic and evolutionary variation of the entire head, which is a structure with a high potential for being a target of selection due to its relevance in ecological and social functions. Here, we describe a non-invasive procedure of geometric morphometrics for exploring morphological variation in the external dorso-ventral view of urodeles' head. To explore the accuracy of the method and its potential for describing morphological patterns we applied it to two populations of Salamandra salamandra gallaica from NW Iberia. Using landmark-based geometric morphometrics, we detected differences in head shape between populations and sexes, and an allometric relationship between shape and size. We also determined that not all differences in head shape are due to size variation, suggesting intrinsic shape differences across sexes and populations. These morphological patterns had not been previously explored in S. salamandra, despite the high levels of intraspecific diversity within this species. The methodological procedure presented here allows to detect shape variation at a very fine scale, and solves the drawbacks of using cranial samples, thus increasing the possibilities of using collection specimens and alive animals for exploring dorsal head shape variation and its evolutionary and ecological implications in urodeles. J. Morphol. 278:475-485, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Ailianou, A; Mundada, P; De Perrot, T; Pusztaszieri, M; Poletti, P-A; Becker, M
2018-04-01
Although diffusion-weighted imaging combined with morphologic MRI (DWIMRI) is used to detect posttreatment recurrent and second primary head and neck squamous cell carcinoma, the diagnostic criteria used so far have not been clarified. We hypothesized that precise MRI criteria based on signal intensity patterns on T2 and contrast-enhanced T1 complement DWI and therefore improve the diagnostic performance of DWIMRI. We analyzed 1.5T MRI examinations of 100 consecutive patients treated with radiation therapy with or without additional surgery for head and neck squamous cell carcinoma. MRI examinations included morphologic sequences and DWI ( b =0 and b =1000 s/mm 2 ). Histology and follow-up served as the standard of reference. Two experienced readers, blinded to clinical/histologic/follow-up data, evaluated images according to clearly defined criteria for the diagnosis of recurrent head and neck squamous cell carcinoma/second primary head and neck squamous cell carcinoma occurring after treatment, post-radiation therapy inflammatory edema, and late fibrosis. DWI analysis included qualitative (visual) and quantitative evaluation with an ADC threshold. Recurrent head and neck squamous cell carcinoma/second primary head and neck squamous cell carcinoma occurring after treatment was present in 36 patients, whereas 64 patients had post-radiation therapy lesions only. The Cohen κ for differentiating tumor from post-radiation therapy lesions with MRI and qualitative DWIMRI was 0.822 and 0.881, respectively. Mean ADCmean in recurrent head and neck squamous cell carcinoma/second primary head and neck squamous cell carcinoma occurring after treatment (1.097 ± 0.295 × 10 -3 mm 2 /s) was significantly lower ( P < .05) than in post-radiation therapy inflammatory edema (1.754 ± 0.343 × 10 -3 mm 2 /s); however, it was similar to that in late fibrosis (0.987 ± 0.264 × 10 -3 mm 2 /s, P > .05). Although ADCs were similar in tumors and late fibrosis, morphologic MRI criteria facilitated distinction between the 2 conditions. The sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios (95% CI) of DWIMRI with ADCmean < 1.22 × 10 -3 mm 2 /s and precise MRI criteria were 92.1% (83.5-100.0), 95.4% (90.3-100.0), 92.1% (83.5-100.0), 95.4% (90.2-100.0), 19.9 (6.58-60.5), and 0.08 (0.03-0.24), respectively, indicating a good diagnostic performance to rule in and rule out disease. Adding precise morphologic MRI criteria to quantitative DWI enables reproducible and accurate detection of recurrent head and neck squamous cell carcinoma/second primary head and neck squamous cell carcinoma occurring after treatment. © 2018 by American Journal of Neuroradiology.
Hayashi, Takahito; Ago, Kazutoshi; Nakamae, Takuma; Higo, Eri; Ogata, Mamoru
2016-06-01
Interleukin (IL)-8 has been suggested to be a positive regulator of myelination in the central nervous system, in addition to its principal role as a chemokine for neutrophils. Immunostaining for beta-amyloid precursor protein (AβPP) is an effective tool for detecting traumatic axonal injury, although AβPP immunoreactivity can also indicate axonal injury due to hypoxic causes. In this study, we examined IL-8 and AβPP immunoreactivity in sections of corpus callosum obtained from deceased patients with blunt head injury and from equivalent control tissue. AβPP immunoreactivity was detected in injured axons, such as axonal bulbs and varicose axons, in 24 of 44 head injury cases. These AβPP immunoreactive cases had survived for more than 3h. The AβPP immunostaining pattern can be classified into two types: traumatic (Pattern 1) and non-traumatic (Pattern 2) axonal injuries, which we described previously [Hayashi et al. Int. J. Legal Med. 129 (2015) 1085-1090]. Three of 44 control cases also showed AβPP immunoreactive injured axons as Pattern 2. In contrast, IL-8 immunoreactivity was detected in 7 AβPP immunoreactive and in 2 non-AβPP immunoreactive head injury cases, but was not detected in any of the 44 control cases, including the 3 AβPP immunoreactive control cases. The IL-8 immunoreactive cases had survived from 3 to 24 days, whereas those cases who survived less than 3 days (n=29) and who survived 90 days (n=1) were not IL-8 immunoreactive. Moreover, IL-8 was detected as Pattern 1 axons only. In addition, double immunofluorescence analysis showed that IL-8 is expressed by oligodendrocytes surrounding injured axons. In conclusion, our results suggest that immunohistochemical detection of IL-8 may be useful as a complementary diagnostic marker of traumatic axonal injury. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Prevedello, Luciano M; Erdal, Barbaros S; Ryu, John L; Little, Kevin J; Demirer, Mutlu; Qian, Songyue; White, Richard D
2017-12-01
Purpose To evaluate the performance of an artificial intelligence (AI) tool using a deep learning algorithm for detecting hemorrhage, mass effect, or hydrocephalus (HMH) at non-contrast material-enhanced head computed tomographic (CT) examinations and to determine algorithm performance for detection of suspected acute infarct (SAI). Materials and Methods This HIPAA-compliant retrospective study was completed after institutional review board approval. A training and validation dataset of noncontrast-enhanced head CT examinations that comprised 100 examinations of HMH, 22 of SAI, and 124 of noncritical findings was obtained resulting in 2583 representative images. Examinations were processed by using a convolutional neural network (deep learning) using two different window and level configurations (brain window and stroke window). AI algorithm performance was tested on a separate dataset containing 50 examinations with HMH findings, 15 with SAI findings, and 35 with noncritical findings. Results Final algorithm performance for HMH showed 90% (45 of 50) sensitivity (95% confidence interval [CI]: 78%, 97%) and 85% (68 of 80) specificity (95% CI: 76%, 92%), with area under the receiver operating characteristic curve (AUC) of 0.91 with the brain window. For SAI, the best performance was achieved with the stroke window showing 62% (13 of 21) sensitivity (95% CI: 38%, 82%) and 96% (27 of 28) specificity (95% CI: 82%, 100%), with AUC of 0.81. Conclusion AI using deep learning demonstrates promise for detecting critical findings at noncontrast-enhanced head CT. A dedicated algorithm was required to detect SAI. Detection of SAI showed lower sensitivity in comparison to detection of HMH, but showed reasonable performance. Findings support further investigation of the algorithm in a controlled and prospective clinical setting to determine whether it can independently screen noncontrast-enhanced head CT examinations and notify the interpreting radiologist of critical findings. © RSNA, 2017 Online supplemental material is available for this article.
Walter, Donald A.; LeBlanc, Denis R.
2008-01-01
Historical weapons testing and disposal activities at Camp Edwards, which is located on the Massachusetts Military Reservation, western Cape Cod, have resulted in the release of contaminants into an underlying sand and gravel aquifer that is the sole source of potable water to surrounding communities. Ground-water models have been used at the site to simulate advective transport in the aquifer in support of field investigations. Reasonable models developed by different groups and calibrated by trial and error often yield different predictions of advective transport, and the predictions lack quantitative measures of uncertainty. A recently (2004) developed regional model of western Cape Cod, modified to include the sensitivity and parameter-estimation capabilities of MODFLOW-2000, was used in this report to evaluate the utility of inverse (statistical) methods to (1) improve model calibration and (2) assess model-prediction uncertainty. Simulated heads and flows were most sensitive to recharge and to the horizontal hydraulic conductivity of the Buzzards Bay and Sandwich Moraines and the Buzzards Bay and northern parts of the Mashpee outwash plains. Conversely, simulated heads and flows were much less sensitive to vertical hydraulic conductivity. Parameter estimation (inverse calibration) improved the match to observed heads and flows; the absolute mean residual for heads improved by 0.32 feet and the absolute mean residual for streamflows improved by about 0.2 cubic feet per second. Advective-transport predictions in Camp Edwards generally were most sensitive to the parameters with the highest precision (lowest coefficients of variation), indicating that the numerical model is adequate for evaluating prediction uncertainties in and around Camp Edwards. The incorporation of an advective-transport observation, representing the leading edge of a contaminant plume that had been difficult to match by using trial-and-error calibration, improved the match between an observed and simulated plume path; however, a modified representation of local geology was needed to simultaneously maintain a reasonable calibration to heads and flows and to the plume path. Advective-transport uncertainties were expressed as about 68-, 95-, and 99-percent confidence intervals on three dimensional simulated particle positions. The confidence intervals can be graphically represented as ellipses around individual particle positions in the X-Y (geographic) plane and in the X-Z or Y-Z (vertical) planes. The merging of individual ellipses allows uncertainties on forward particle tracks to be displayed in map or cross-sectional view as a cone of uncertainty around a simulated particle path; uncertainties on reverse particle-track endpoints - representing simulated recharge locations - can be geographically displayed as areas at the water table around the discrete particle endpoints. This information gives decisionmakers insight into the level of confidence they can have in particle-tracking results and can assist them in the efficient use of available field resources.
NASA Astrophysics Data System (ADS)
Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun
2006-06-01
This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.
On the barn owl's visual pre-attack behavior: I. Structure of head movements and motion patterns.
Ohayon, Shay; van der Willigen, Robert F; Wagner, Hermann; Katsman, Igor; Rivlin, Ehud
2006-09-01
Barn owls exhibit a rich repertoire of head movements before taking off for prey capture. These movements occur mainly at light levels that allow for the visual detection of prey. To investigate these movements and their functional relevance, we filmed the pre-attack behavior of barn owls. Off-line image analysis enabled reconstruction of all six degrees of freedom of head movements. Three categories of head movements were observed: fixations, head translations and head rotations. The observed rotations contained a translational component. Head rotations did not follow Listing's law, but could be well described by a second-order surface, which indicated that they are in close agreement with Donder's law. Head translations did not contain any significant rotational components. Translations were further segmented into straight-line and curved paths. Translations along an axis perpendicular to the line of sight were similar to peering movements observed in other animals. We suggest that these basic motion elements (fixations, head rotations, translations along a straight line, and translation along a curved trajectory) may be combined to form longer and more complex behavior. We speculate that these head movements mainly underlie estimation of distance during prey capture.
Factor Analytic Approach to Transitive Text Mining using Medline Descriptors
NASA Astrophysics Data System (ADS)
Stegmann, J.; Grohmann, G.
Matrix decomposition methods were applied to examples of noninteractive literature sets sharing implicit relations. Document-by-term matrices were created from downloaded PubMed literature sets, the terms being the Medical Subject Headings (MeSH descriptors) assigned to the documents. The loadings of the factors derived from singular value or eigenvalue matrix decomposition were sorted according to absolute values and subsequently inspected for positions of terms relevant to the discovery of hidden connections. It was found that only a small number of factors had to be screened to find key terms in close neighbourhood, being separated by a small number of terms only.
Gulini, U; Angeli, P; Marucci, G; Buccioni, M; Giardinà, D; Antolini, L; Franchini, S; Sorbi, C; Brasili, L
2001-01-22
Methylation of the carbon atom C of compound 1, a potent and not selective muscarinic antagonist, was carried out. The resulting diastereomers were separated and the corresponding racemate further resolved to give four enantiomers, which were tested both as hydrogen oxalate and methiodide salts. The pharmacological results obtained at M1, M2 and M3 muscarinic receptor subtypes, show that methylation at C1, depending on the stereochemistry, increases antagonist potency, having thus the same effect of nitrogen quaternization. These results may well lead to the development of new potent antimuscarinic drugs lacking a cationic head.
High-resolution absolute position detection using a multiple grating
NASA Astrophysics Data System (ADS)
Schilling, Ulrich; Drabarek, Pawel; Kuehnle, Goetz; Tiziani, Hans J.
1996-08-01
To control electro-mechanical engines, high-resolution linear and rotary encoders are needed. Interferometric methods (grating interferometers) promise a resolution of a few nanometers, but have an ambiguity range of some microns. Incremental encoders increase the absolute measurement range by counting the signal periods starting from a defined initial point. In many applications, however, it is not possible to move to this initial point, so that absolute encoders have to be used. Absolute encoders generally have a scale with two or more tracks placed next to each other. Therefore, they use a two-dimensional grating structure to measure a one-dimensional position. We present a new method, which uses a one-dimensional structure to determine the position in one dimension. It is based on a grating with a large grating period up to some millimeters, having the same diffraction efficiency in several predefined diffraction orders (multiple grating). By combining the phase signals of the different diffraction orders, it is possible to establish the position in an absolute range of the grating period with a resolution like incremental grating interferometers. The principal functionality was demonstrated by applying the multiple grating in a heterodyne grating interferometer. The heterodyne frequency was generated by a frequency modulated laser in an unbalanced interferometer. In experimental measurements an absolute range of 8 mm was obtained while achieving a resolution of 10 nm.
Liquid Biopsy: A Future Tool for Posttreatment Surveillance in Head and Neck Cancer?
van Ginkel, Joost H; Huibers, Manon M H; Noorlag, Rob; de Bree, Remco; van Es, Robert J J; Willems, Stefan M
2017-01-01
The prognosis of head and neck squamous cell carcinoma (HNSCC) is largely based on disease stage. Despite improvements in treatment, recurrence rates are still considered high. Currently, disease progression or regression after curative treatment is monitored by clinical evaluation combined with flexible endoscopy and/or imaging. However, specificity of imaging is low due to the posttreatment effects. Detection of circulating tumor DNA (ctDNA) from blood samples of HNSCC patients is a minimally invasive technique that could lead to an earlier detection of recurrence. In addition, digital droplet PCR (ddPCR) could be used to sensitively detect these mutational targets. Future study on ctDNA using ddPCR in blood samples of HNSCC patients is recommended during the follow-up stage to detect recurrences in a timely manner. © 2016 S. Karger AG, Basel.
Dax Gets the Nod: Toddlers Detect and Use Social Cues to Evaluate Testimony
Fusaro, Maria; Harris, Paul L.
2016-01-01
Children ages 18 and 24 months were assessed for the ability to understand and learn from an adult’s nonverbal expression of agreement and disagreement with a speaker’s claims. In one type of communicative exchange, a speaker made 2 different claims about the identity or location of an object. The hearer nodded her head in agreement with one claim and shook her head in disagreement with the other claim. In a second type of exchange, the speaker asked 2 different questions about the identity or location of an object. The hearer nodded her head in response to one question and shook her head in response to the other. The 24-month-olds grasped the implication of these gestural responses, by inferring the correct name or location of the object. The 18-month-olds showed a limited grasp of their implications. Thus, in learning from others’ testimony, toddlers focus not only on the claims of a single speaker but also on whether that information is accepted or rejected by another hearer. In particular, they detect and act on social cues of assent and dissent. PMID:23127298
Zammit-Maempel, I; Kurien, R; Paleri, V
2016-06-01
To investigate the long-term outcomes of pulmonary nodules detected on chest computed tomography in a consecutive cohort of patients with newly diagnosed or recurrent head and neck squamous cell cancer staged between 2001 and 2003. The study included 222 patients, 148 patients with newly diagnosed head and neck cancer (group 1) and 74 patients with recurrent cancer (group 2). Abnormalities were identified in 101 patients (45.4 per cent); these were predominantly benign in group 1 (61.7 per cent) as compared to predominantly malignant in group 2 (64.3 per cent) (Fisher's exact test; p = 0.0009). Only four patients (7.4 per cent) with an initially benign-looking pulmonary nodule went on to develop malignancy over time, conferring a negative predictive value of 93 per cent for the whole cohort. Chest computed tomography abnormalities in patients with recurrent head and neck cancer are statistically more likely to be malignant. Very few patients with an initially benign-appearing nodule develop chest malignancy over time.
Paolini, Marco; Keeser, Daniel; Ingrisch, Michael; Werner, Natalie; Kindermann, Nicole; Reiser, Maximilian; Blautzik, Janusch
2015-05-01
Little research exists on the influence of a magnetic resonance imaging (MRI) head coil's channel count on measured resting-state functional connectivity. To compare a 32-element (32ch) and an 8-element (8ch) phased array head coil with respect to their potential to detect functional connectivity within resting-state networks. Twenty-six healthy adults (mean age, 21.7 years; SD, 2.1 years) underwent resting-state functional MRI at 3.0 Tesla with both coils using equal standard imaging parameters and a counterbalanced design. Independent component analysis (ICA) at different model orders and a dual regression approach were performed. Voxel-wise non-parametric statistical between-group contrasts were determined using permutation-based non-parametric inference. Phantom measurements demonstrated a generally higher image signal-to-noise ratio using the 32ch head coil. However, the results showed no significant differences between corresponding resting-state networks derived from both coils (p < 0.05, FWE-corrected). Using the identical standard acquisition parameters, the 32ch head coil does not offer any significant advantages in detecting ICA-based functional connectivity within RSNs. © The Foundation Acta Radiologica 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Evidence for Acute Electrophysiological and Cognitive Changes Following Routine Soccer Heading.
Di Virgilio, Thomas G; Hunter, Angus; Wilson, Lindsay; Stewart, William; Goodall, Stuart; Howatson, Glyn; Donaldson, David I; Ietswaart, Magdalena
2016-11-01
There is growing concern around the effects of concussion and sub-concussive impacts in sport. Routine game-play in soccer involves intentional and repeated head impacts through ball heading. Although heading is frequently cited as a risk to brain health, little data exist regarding the consequences of this activity. This study aims to assess the immediate outcomes of routine football heading using direct and sensitive measures of brain function. Nineteen amateur football players (5 females; age 22±3y) headed machine-projected soccer balls at standardized speeds, modelling routine soccer practice. The primary outcome measure of corticomotor inhibition measured using transcranial magnetic stimulation, was assessed prior to heading and repeated immediately, 24h, 48h and 2weeks post-heading. Secondary outcome measures were cortical excitability, postural control, and cognitive function. Immediately following heading an increase in corticomotor inhibition was detected; further to these electrophysiological alterations, measurable reduction memory function were also found. These acute changes appear transient, with values normalizing 24h post-heading. Sub-concussive head impacts routine in soccer heading are associated with immediate, measurable electrophysiological and cognitive impairments. Although these changes in brain function were transient, these effects may signal direct consequences of routine soccer heading on (long-term) brain health which requires further study. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Malvasi, Antonio; Stark, Michael; Ghi, Tullio; Farine, Dan; Guido, Marcello; Tinelli, Andrea
2012-05-01
The primary goal of this study was to determine the ultrasonographic signs of asynclitic and transverse head positioning. In addition, we compared the performance of intrapartum ultrasound to vaginal digital examination. 150 women were evaluated by 2D transabdominal and translabial ultrasound (US) to detect the asynclitic and deep transverse positions. Transvaginal sterile digital examinations were performed immediately after each intrapartum US assessments, the examinations were repeated at intervals of 45-90 minutes. Examiners were blinded to each other's findings (clinical or sonographic). Data were reviewed and analyzed by an independent reviewer. The efficacy of digital examination was significantly lower than US evaluation for the detection of either transverse position or asynclitism. The most frequent transverse position was the left one, while the most frequent asynclitism was the anterior one. Digital pelvic examination for detection of fetal head transverse position during labor is inferior to US, especially in the deep transverse positioning, where caput succedaneum occurs and reduces the diagnostic accuracy of vaginal digital examination. The US examination leads to early detection of persistent transverse position allowing for earlier timing and optimal technique for the operative vaginal delivery. We describe two signs for diagnosing asynclitism. The "squint sign" and the "sunset of thalamus and cerebellum signs" are two simple US signs allowing detection of anterior and posterior asynclitism.
Araki, Koji; Mizokami, Daisuke; Tomifuji, Masayuki; Yamashita, Taku; Ohnuki, Kazunobu; Umeda, Izumi O; Fujii, Hirofumi; Kosuda, Shigeru; Shiotani, Akihiro
2014-08-01
Sentinel node navigation surgery using real-time, near-infrared imaging with indocyanine green is becoming popular by allowing head and neck surgeons to avoid unnecessary neck dissection. The major drawback of this method is its quick migration through the lymphatics, limiting the diagnostic time window and undesirable detection of downstream nodes. We resolved this problem by mixing indocyanine green (ICG) with phytate colloid to retard its migration and demonstrated its feasibility in a nude mouse study. Experimental prospective animal study. Animal laboratory. Indocyanine green at 3 concentrations was tested to determine the optimal concentration for sentinel lymph node detection in a mouse model. Effect of indocyanine green with phytate colloid mixture solutions was also analyzed. Indocyanine green or mixture solution at different mixing ratios were injected into the tongue of nude mice and near-infrared fluorescence images were captured sequentially for up to 48 hours. The brightness of fluorescence in the sentinel lymph node and lymph nodes further downstream were assessed. Indocyanine green concentration >50 μg/mL did not improve sentinel lymph node detection. The addition of phytate colloid to indocyanine green extended the period when sentinel lymph node was detectable. Second echelon lymph nodes were not imaged in mice injected with the mixture, while these were visualized in mice injected with indocyanine green alone. This novel technique of ICG-phytate colloid mixture allows prolonged diagnostic time window, prevention of downstream subsequent nodes detection, and improved accuracy for the detection of true sentinel lymph nodes. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.
The 200 MeV Pi+ induced single-nucleon removal from 24Mg
NASA Technical Reports Server (NTRS)
Joyce, Donald; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph; Lieb, B. Joseph;
1985-01-01
Nuclear gamma-rays in coincidence with outgoing pions or protons following single nucleon removal from Mg-24 by 200 MeV pions (+) were detected with Ge(Li) detectors. Differential cross sections are reported for gamma-rays from the first excited mirror states of Na-23 and Mg-23 in coincidence with positive pions or protons detected in particle telescopes at 30, 60, 90, 120, and 150 deg; angle-integrated absolute cross sections and cross section ratios are calculated. These results are compared with the predictions of a Pauli-blocked plane-wave impulse approximation (PWIA) and the intranuclear cascade (INC) and nucleon charge exchange (NCX) reaction models. The PWIA and the INC calculations generally agree with the angular dependence of the experimental results but not the absolute magnitude. The NCX calculation does not reproduce the observed cross section charge ratios.
Digital PCR provides absolute quantitation of viral load for an occult RNA virus.
White, Richard Allen; Quake, Stephen R; Curr, Kenneth
2012-01-01
Using a multiplexed LNA-based Taqman assay, RT-digital PCR (RT-dPCR) was performed in a prefabricated microfluidic device that monitored absolute viral load in native and immortalized cell lines, overall precision of detection, and the absolute detection limit of an occult RNA virus GB Virus Type C (GBV-C). RT-dPCR had on average a 10% lower overall coefficient of variation (CV, a measurement of precision) for viral load testing than RT-qPCR and had a higher overall detection limit, able to quantify as low as three 5'-UTR molecules of GBV-C genome. Two commercial high-yield in vitro transcription kits (T7 Ribomax Express by Promega and Ampliscribe T7 Flash by Epicentre) were compared to amplify GBV-C RNA genome with T7-mediated amplification. The Ampliscribe T7 Flash outperformed the T7 Ribomax Express in yield of full-length GBV-C RNA genome. THP-1 cells (a model of monocytic derived cells) were transfected with GBV-C, yielding infectious virions that replicated over a 120h time course and could be infected directly. This study provides the first evidence of GBV-C replication in monocytic derived clonal cells. Thus far, it is the only study using a microfluidic device that measures directly viral load of mammalian RNA virus in a digital format without need for a standard curve. Copyright © 2011 Elsevier B.V. All rights reserved.
Ultrasensitive mechanical detection of magnetic moment using a commercial disk drive write head
Tao, Y.; Eichler, A.; Holzherr, T.; Degen, C. L.
2016-01-01
Sensitive detection of weak magnetic moments is an essential capability in many areas of nanoscale science and technology, including nanomagnetism, quantum readout of spins and nanoscale magnetic resonance imaging. Here we show that the write head of a commercial hard drive may enable significant advances in nanoscale spin detection. By approaching a sharp diamond tip to within 5 nm from a write pole and measuring the induced diamagnetic moment with a nanomechanical force transducer, we demonstrate a spin sensitivity of 0.032 μB Hz−1/2, equivalent to 21 proton magnetic moments. The high sensitivity is enabled in part by the pole's strong magnetic gradient of up to 28 × 106 T m−1 and in part by the absence of non-contact friction due to the extremely flat writer surface. In addition, we demonstrate quantitative imaging of the pole field with ∼10 nm spatial resolution. We foresee diverse applications for write heads in experimental condensed matter physics, especially in spintronics, ultrafast spin manipulation and mesoscopic physics. PMID:27647039
Fibre Optic Mechanical Sensors For Aerospace Applications
NASA Astrophysics Data System (ADS)
Batchellor, C. R.; Dakin, J. P.; Pearce, D. A. J.
1989-04-01
A fiber optic multisensor methane detection system matched to topology and environment of a coal mine is reported. The system involves time domain multiplexed (TDM) methane sensors based on selective absorption of source radiation by atomic or molecular species in the gas sensing heads. A two-wavelength ratiometric approach allows simple self referencing, cancels out errors arising from other contaminants, and improves the measurement contrast. The laboratory system consists of a high radiance LED source, multimode fiber, optical sensing head, optical bandpass filters, and involves synchronous detection with low noise photodiodes and a lock-in amplifier. Detection sensitivity upon spectral resolution of the optical filters has also been investigated and described. The system performance was evaluated and the results are presented.
Magnetic force microscopy study on wide adjacent track erasure in perpendicular magnetic write heads
NASA Astrophysics Data System (ADS)
Ruksasakchai, P.; Saengkaew, K.; Cheowanish, I.; Damrongsak, B.
2017-09-01
We used a phase-contrast magnetic force microscopy (MFM) to observe and analyze the failure of magnetic write heads due to the WATEr problem, which limits the off-track performance. During MFM imaging, the magnetic write head was energized by a DC current. The induced out-of-plane magnetic field was then detected by scanning a MFM probe across the surface of the magnetic write head. MFM images were then mapped with WATEr measured results from a spin stand method. Results showed that WATEr effect can be generated by several factors, i.e. the structure of magnetic domains and walls from material discontinuities and the magnetic field leakage at different locations on magnetic write heads. Understanding WATEr mechanisms is useful for design and process development engineers.
Head pose estimation in computer vision: a survey.
Murphy-Chutorian, Erik; Trivedi, Mohan Manubhai
2009-04-01
The capacity to estimate the head pose of another person is a common human ability that presents a unique challenge for computer vision systems. Compared to face detection and recognition, which have been the primary foci of face-related vision research, identity-invariant head pose estimation has fewer rigorously evaluated systems or generic solutions. In this paper, we discuss the inherent difficulties in head pose estimation and present an organized survey describing the evolution of the field. Our discussion focuses on the advantages and disadvantages of each approach and spans 90 of the most innovative and characteristic papers that have been published on this topic. We compare these systems by focusing on their ability to estimate coarse and fine head pose, highlighting approaches that are well suited for unconstrained environments.
Welk, Blayne; McArthur, Eric; Fraser, Lisa-Ann; Hayward, Jade; Dixon, Stephanie; Hwang, Y Joseph; Ordon, Michael
2015-10-26
Do men starting treatment with prostate-specific α antagonists have increased risk of fall and fracture? Administrative datasets from the province of Ontario, Canada, that contain patient level data were used to generate a cohort of 147,084 men aged ≥ 66 years who filled their first outpatient prescription for prostate-specific α antagonists tamsulosin, alfuzosin, or silodosin between June 2003 and December 2013 (exposed men) plus an equal sized cohort matched 1:1 (using a propensity score model) who did not initiate α antagonist therapy. The primary outcome was a hospital emergency room visit or inpatient admission for a fall or fracture in the 90 days after exposure. The men exposed to prostate-specific α antagonist had significantly increased risks of falling (odds ratio 1.14 (95% CI 1.07 to 1.21), absolute risk increase 0.17% (0.08 to 0.25%)) and of sustaining a fracture (odds ratio 1.16 (1.04 to 1.29), absolute risk increase 0.06% (0.02 to 0.11%)) compared with the unexposed cohort. This increased risk was not observed in the period before α antagonist use. Secondary outcomes of hypotension and head trauma were also significantly increased in the exposed cohort (odds ratios 1.80 (1.59 to 2.03) and 1.15 (1.04 to 1.27) respectively). The two cohorts were similar across 98 different covariates including demographics, comorbid conditions, medication use, healthcare use, and prior medical investigation. Potential unmeasured confounders, such as physical deconditioning, mobility impairment, and situational risk factors, may exist. The data used to identify the primary outcomes had limited sensitivity, so the absolute risks of the outcomes are probably underestimates. The study only included men ≥ 66 years old, and 84% of exposed men were prescribed tamsulosin, so results may not be generalizable to younger men, and there may not be statistical power to show small differences in outcomes between the drugs. Prostate-specific α antagonists are associated with a small but significant increased risk of fall, fracture, and head trauma, probably as a result of induced hypotension. This project was conducted at the Institute for Clinical Evaluative Sciences (ICES) Western Site through the Kidney, Dialysis, and Transplantation (KDT) research program. BW has received a research grant from Astellas, and L-AF does consultancy for Amgen. © Welk et al 2015.
Mechanism of chlorogenic acid treatment on femoral head necrosis and its protection of osteoblasts.
Zhang, Mingjuan; Hu, Xianda
2016-07-01
The aim of the present study was to investigate the therapeutic effect of chlorogenic acid on hormonal femoral head necrosis and its protection of osteoblasts. The study established a femoral head necrosis model in Wistar rats using Escherichia coli endotoxin and prednisolone acetate. The rats were divided into five groups and were treated with different concentrations of chlorogenic acid (1, 10 and 20 mg/kg). The main detected indicators were the blood rheology, bone mineral density, and the hydroxyproline and hexosamine (HOM) contents. At a cellular level, osteoblasts were cultured and treated by drug-containing serum. Subsequently, cell proliferation and the osteoblast cycle were measured using flow cytometry, and the protein expression levels of Bax and B-cell lymphoma 2 (Bcl-2) were detected using western blotting. Chlorogenic acid at a concentration of 20 mg/kg (high-dose) enhanced the bone mineral density of the femoral head and femoral neck following ischemia. Simultaneously, blood flow following the injection of prednisolone acetate was significantly improved, and the HOM contents of the high-dose chlorogenic acid group were significantly different. The results from the flow cytometry analysis indicated that chlorogenic acid can efficiently ameliorate hormone-induced necrosis. The osteoblasts were isolated and cultured. The MTT colorimetric assay showed that chlorogenic acid at different densities can increase the proliferation capabilities of osteoblasts and accelerate the transition process of G 0 /G 1 phase to S phase, as well as enhance mitosis and the regeneration of osteoblasts. Western blotting detection indicated that chlorogenic acid may prohibit the decrease of Bcl-2 and the increase of Bax during apoptosis, thereby inhibiting osteoblast apoptosis and preventing the deterioration of femoral head necrosis. In conclusion, chlorogenic acid at the density of 20 mg/kg is effective in the treatment of hormonal femoral head necrosis, which may be applicable for future treatment.
NASA Astrophysics Data System (ADS)
Wziontek, H.; Palinkas, V.; Falk, R.; Vaľko, M.
2016-12-01
Since decades, absolute gravimeters are compared on a regular basis on an international level, starting at the International Bureau for Weights and Measures (BIPM) in 1981. Usually, these comparisons are based on constant reference values deduced from all accepted measurements acquired during the comparison period. Temporal changes between comparison epochs are usually not considered. Resolution No. 2, adopted by IAG during the IUGG General Assembly in Prague 2015, initiates the establishment of a Global Absolute Gravity Reference System based on key comparisons of absolute gravimeters (AG) under the International Committee for Weights and Measures (CIPM) in order to establish a common level in the microGal range. A stable and unique reference frame can only be achieved, if different AG are taking part in different kind of comparisons. Systematic deviations between the respective comparison reference values can be detected, if the AG can be considered stable over time. The continuous operation of superconducting gravimeters (SG) on selected stations further supports the temporal link of comparison reference values by establishing a reference function over time. By a homogenous reprocessing of different comparison epochs and including AG and SG time series at selected stations, links between several comparisons will be established and temporal comparison reference functions will be derived. By this, comparisons on a regional level can be traced to back to the level of key comparisons, providing a reference for other absolute gravimeters. It will be proved and discussed, how such a concept can be used to support the future absolute gravity reference system.
Head rice rate measurement based on concave point matching
Yao, Yuan; Wu, Wei; Yang, Tianle; Liu, Tao; Chen, Wen; Chen, Chen; Li, Rui; Zhou, Tong; Sun, Chengming; Zhou, Yue; Li, Xinlu
2017-01-01
Head rice rate is an important factor affecting rice quality. In this study, an inflection point detection-based technology was applied to measure the head rice rate by combining a vibrator and a conveyor belt for bulk grain image acquisition. The edge center mode proportion method (ECMP) was applied for concave points matching in which concave matching and separation was performed with collaborative constraint conditions followed by rice length calculation with a minimum enclosing rectangle (MER) to identify the head rice. Finally, the head rice rate was calculated using the sum area of head rice to the overall coverage of rice. Results showed that bulk grain image acquisition can be realized with test equipment, and the accuracy rate of separation of both indica rice and japonica rice exceeded 95%. An increase in the number of rice did not significantly affect ECMP and MER. High accuracy can be ensured with MER to calculate head rice rate by narrowing down its relative error between real values less than 3%. The test results show that the method is reliable as a reference for head rice rate calculation studies. PMID:28128315
Vordermark, Dirk; Said, Harun M; Katzer, Astrid; Kuhnt, Thomas; Hänsgen, Gabriele; Dunst, Jürgen; Flentje, Michael; Bache, Matthias
2006-08-15
The tumor-associated glycoprotein osteopontin (OPN) is discussed as a plasma surrogate marker of tumor hypoxia and as an indicator of the presence of pleural mesothelioma in asbestos-exposed individuals. The clinical introduction of plasma OPN measurements requires the availability of a reliable enzyme-linked immunosorbence assay (ELISA). We compared previously described and currently available ELISA systems on 88 archival plasma samples obtained from patients with head and neck or cervix cancer between 20 days before and 171 after the start of radiotherapy. Median (range) plasma OPN levels were 667 (148.8-2095) ng/ml and 9.8 (3.5-189.5) ng/ml for a previously described and a newly marketed assay, respectively. Although results for different assays were significantly correlated (r = 0.38, p < 0.05, Spearman rank test), between-assay factors ranged from 2.0 to 217.9 (median 74.6) in individual patients. OPN levels in cervix cancer patients were comparable to those of head and neck cancer patients. Commercially available OPN ELISA systems produce different absolute plasma OPN levels, compromising a comparison of individual patient data with published results. However, different assays appear to have a similar capacity to rank patients according to plasma OPN level. A review of literature data suggests that plasma OPN levels measured even with identical ELISA systems can only be compared with caution.
Cullen, Kathleen E.
2014-01-01
The vestibular system is vital for maintaining an accurate representation of self-motion. As one moves (or is moved) toward a new place in the environment, signals from the vestibular sensors are relayed to higher-order centers. It is generally assumed the vestibular system provides a veridical representation of head motion to these centers for the perception of self-motion and spatial memory. In support of this idea, evidence from lesion studies suggests that vestibular inputs are required for the directional tuning of head direction cells in the limbic system as well as neurons in areas of multimodal association cortex. However, recent investigations in monkeys and mice challenge the notion that early vestibular pathways encode an absolute representation of head motion. Instead, processing at the first central stage is inherently multimodal. This minireview highlights recent progress that has been made towards understanding how the brain processes and interprets self-motion signals encoded by the vestibular otoliths and semicircular canals during everyday life. The following interrelated questions are considered. What information is available to the higher-order centers that contribute to self-motion perception? How do we distinguish between our own self-generated movements and those of the external world? And lastly, what are the implications of differences in the processing of these active vs. passive movements for spatial memory? PMID:24454282
Child Poverty, the Great Recession, and the Social Safety Net in the United States.
Bitler, Marianne; Hoynes, Hiliary; Kuku, Elira
In this paper, we comprehensively examine the effects of the Great Recession on child poverty, with particular attention to the role of the social safety net in mitigating the adverse effects of shocks to earnings and income. Using a state panel data model and data for 2000 to 2014, we estimate the relationship between the business cycle and child poverty, and we examine how and to what extent the safety net is providing protection to at-risk children. We find compelling evidence that the safety net provides protection; that is, the cyclicality of after-tax-and-transfer child poverty is significantly attenuated relative to the cyclicality of private income poverty. We also find that the protective effect of the safety net is not similar across demographic groups, and that children from more disadvantaged backgrounds, such as those living with Hispanic or single heads, or particularly those living with immigrant household heads—or immigrant spouses—experience larger poverty cyclicality than those living with non- Hispanic white or married heads, or those living with native household heads with native spouses. Our findings hold across a host of choices for how to define poverty. These include measures based on absolute thresholds or more relative thresholds. They also hold for measures of resources that include not only cash and near-cash transfers net of taxes but also several measures of the value of public medical benefits.
Oscillating-Linear-Drive Vacuum Compressor for CO2
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Shimko, Martin
2005-01-01
A vacuum compressor has been designed to compress CO2 from approximately equal to 1 psia (approximately equal to 6.9 kPa absolute pressure) to approximately equal to 75 psia (approximately equal to 0.52 MPa), to be insensitive to moisture, to have a long operational life, and to be lightweight, compact, and efficient. The compressor consists mainly of (1) a compression head that includes hydraulic diaphragms, a gas-compression diaphragm, and check valves; and (2) oscillating linear drive that includes a linear motor and a drive spring, through which compression force is applied to the hydraulic diaphragms. The motor is driven at the resonance vibrational frequency of the motor/spring/compression-head system, the compression head acting as a damper that takes energy out of the oscillation. The net effect of the oscillation is to cause cyclic expansion and contraction of the gas-compression diaphragm, and, hence, of the volume bounded by this diaphragm. One-way check valves admit gas into this volume from the low-pressure side during expansion and allow the gas to flow out to the high-pressure side during contraction. Fatigue data and the results of diaphragm stress calculations have been interpreted as signifying that the compressor can be expected to have an operational life of greater than 30 years with a confidence level of 99.9 percent.
NIR light propagation in a digital head model for traumatic brain injury (TBI)
Francis, Robert; Khan, Bilal; Alexandrakis, George; Florence, James; MacFarlane, Duncan
2015-01-01
Near infrared spectroscopy (NIRS) is capable of detecting and monitoring acute changes in cerebral blood volume and oxygenation associated with traumatic brain injury (TBI). Wavelength selection, source-detector separation, optode density, and detector sensitivity are key design parameters that determine the imaging depth, chromophore separability, and, ultimately, clinical usefulness of a NIRS instrument. We present simulation results of NIR light propagation in a digital head model as it relates to the ability to detect intracranial hematomas and monitor the peri-hematomal tissue viability. These results inform NIRS instrument design specific to TBI diagnosis and monitoring. PMID:26417498
Water-soluble cationic conjugated polymers: response to electron-rich bioanalytes.
Rochat, Sébastien; Swager, Timothy M
2013-11-27
We report the concise synthesis of a symmetrical monomer that provides a head-to-head pyridine building block for the preparation of cationic conjugated polymers. The obtained poly(pyridinium-phenylene) polymers display appealing properties such as high electron affinity, charge-transport upon n-doping, and optical response to electron-donating analytes. A simple assay for the optical detection of low micromolar amounts of a variety of analytes in aqueous solution was developed. In particular, caffeine could be measured at a 25 μM detection limit. The reported polymers are also suitable for layer-by-layer film formation.
Optical Johnson noise thermometry
Shepard, Robert L.; Blalock, Theron V.; Roberts, Michael J.; Maxey, Lonnie C.
1992-01-01
Method and device for direct, non-contact temperature measure of a body. A laser beam is reflected from the surface of the body and detected along with the Planck radiation. The detected signal is analyzed using signal correlation technique to generate an output signal proportional to the Johnson noise introduced into the reflected laser beam as a direct measure of the absolute temperature of the body.
Python Waveform Cross-Correlation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Templeton, Dennise
PyWCC is a tool to compute seismic waveform cross-correlation coefficients on single-component or multiple-component seismic data across a network of seismic sensors. PyWCC compares waveform data templates with continuous seismic data, associates the resulting detections, identifies the template with the highest cross-correlation coefficient, and outputs a catalog of detections above a user-defined absolute cross-correlation threshold value.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Randeniya, S; Mirkovic, D; Titt, U
2014-06-01
Purpose: In intensity modulated proton therapy (IMPT), energy dependent, protons per monitor unit (MU) calibration factors are important parameters that determine absolute dose values from energy deposition data obtained from Monte Carlo (MC) simulations. Purpose of this study was to assess the sensitivity of MC-computed absolute dose distributions to the protons/MU calibration factors in IMPT. Methods: A “verification plan” (i.e., treatment beams applied individually to water phantom) of a head and neck patient plan was calculated using MC technique. The patient plan had three beams; one posterior-anterior (PA); two anterior oblique. Dose prescription was 66 Gy in 30 fractions. Ofmore » the total MUs, 58% was delivered in PA beam, 25% and 17% in other two. Energy deposition data obtained from the MC simulation were converted to Gy using energy dependent protons/MU calibrations factors obtained from two methods. First method is based on experimental measurements and MC simulations. Second is based on hand calculations, based on how many ion pairs were produced per proton in the dose monitor and how many ion pairs is equal to 1 MU (vendor recommended method). Dose distributions obtained from method one was compared with those from method two. Results: Average difference of 8% in protons/MU calibration factors between method one and two converted into 27 % difference in absolute dose values for PA beam; although dose distributions preserved the shape of 3D dose distribution qualitatively, they were different quantitatively. For two oblique beams, significant difference in absolute dose was not observed. Conclusion: Results demonstrate that protons/MU calibration factors can have a significant impact on absolute dose values in IMPT depending on the fraction of MUs delivered. When number of MUs increases the effect due to the calibration factors amplify. In determining protons/MU calibration factors, experimental method should be preferred in MC dose calculations. Research supported by National Cancer Institute grant P01CA021239.« less
Liu, Quanying; Ganzetti, Marco; Wenderoth, Nicole; Mantini, Dante
2018-01-01
Resting state networks (RSNs) in the human brain were recently detected using high-density electroencephalography (hdEEG). This was done by using an advanced analysis workflow to estimate neural signals in the cortex and to assess functional connectivity (FC) between distant cortical regions. FC analyses were conducted either using temporal (tICA) or spatial independent component analysis (sICA). Notably, EEG-RSNs obtained with sICA were very similar to RSNs retrieved with sICA from functional magnetic resonance imaging data. It still remains to be clarified, however, what technological aspects of hdEEG acquisition and analysis primarily influence this correspondence. Here we examined to what extent the detection of EEG-RSN maps by sICA depends on the electrode density, the accuracy of the head model, and the source localization algorithm employed. Our analyses revealed that the collection of EEG data using a high-density montage is crucial for RSN detection by sICA, but also the use of appropriate methods for head modeling and source localization have a substantial effect on RSN reconstruction. Overall, our results confirm the potential of hdEEG for mapping the functional architecture of the human brain, and highlight at the same time the interplay between acquisition technology and innovative solutions in data analysis. PMID:29551969
Papa, Linda; Zonfrillo, Mark; Ramirez, Jose; Silvestri, Salvatore; Giordano, Philip; Braga, Carolina F.; Tan, Ciara N.; Ameli, Neema J.; Lopez, Marco; Mittal, Manoj K.
2015-01-01
Objectives This study examined the performance of serum glial fibrillary acidic protein (GFAP) in detecting traumatic intracranial lesions on computed tomography (CT) scan in children and youth with mild and moderate traumatic brain injury (TBI), and assessed its performance in trauma control patients without head trauma. Methods This prospective cohort study enrolled children and youth presenting to three Level I trauma centers following blunt head trauma with Glasgow Coma Scale (GCS) scores of 9 to 15, as well as trauma control patients with GCS scores of 15 who did not have blunt head trauma. The primary outcome measure was the presence of intracranial lesions on initial CT scan. Blood samples were obtained in all patients within six hours of injury and measured by ELISA for GFAP (ng/ml). Results A total of 257 children and youth were enrolled in the study and had serum samples drawn within 6 hours of injury for analysis: 197 had blunt head trauma and 60 were trauma controls. CT scan of the head was performed in 152 patients and traumatic intracranial lesions on CT scan were evident in 18 (11%), all of whom had GCS scores of 13 to 15. When serum levels of GFAP were compared in children and youth with traumatic intracranial lesions on CT scan to those without CT lesions, median GFAP levels were significantly higher in those with intracranial lesions (1.01, IQR 0.59 to 1.48) than those without lesions (0.18, IQR 0.06 to 0.47). The area under the receiver operating characteristic (ROC) curve (AUC) for GFAP in detecting children and youth with traumatic intracranial lesions on CT was 0.82 (95% CI = 0.71 to 0.93). In those presenting with GCS scores of 15, the AUC for detecting lesions was 0.80 (95% CI = 0.68 to 0.92). Similarly, in children under five years old the AUC was 0.83 (95% CI = 0.56 to 1.00). Performance for detecting intracranial lesions at a GFAP cutoff level of 0.15 ng/ml yielded a sensitivity of 94%, a specificity of 47%, and a negative predictive value of 98%. Conclusions In children and youth of all ages, GFAP measured within 6 hours of injury was associated with traumatic intracranial lesions on CT and with severity of TBI. Further study is required to validate these findings before clinical application. PMID:26469937
Liu, Jin-Ya; Chen, Li-Da; Cai, Hua-Song; Liang, Jin-Yu; Xu, Ming; Huang, Yang; Li, Wei; Feng, Shi-Ting; Xie, Xiao-Yan; Lu, Ming-De; Wang, Wei
2016-01-01
AIM: To present our initial experience regarding the feasibility of ultrasound virtual endoscopy (USVE) and its measurement reliability for polyp detection in an in vitro study using pig intestine specimens. METHODS: Six porcine intestine specimens containing 30 synthetic polyps underwent USVE, computed tomography colonography (CTC) and optical colonoscopy (OC) for polyp detection. The polyp measurement defined as the maximum polyp diameter on two-dimensional (2D) multiplanar reformatted (MPR) planes was obtained by USVE, and the absolute measurement error was analyzed using the direct measurement as the reference standard. RESULTS: USVE detected 29 (96.7%) of 30 polyps, remaining a 7-mm one missed. There was one false-positive finding. Twenty-six (89.7%) of 29 reconstructed images were clearly depicted, while 29 (96.7%) of 30 polyps were displayed on CTC with one false-negative finding. In OC, all the polyps were detected. The intraclass correlation coefficient was 0.876 (95%CI: 0.745-0.940) for measurements obtained with USVE. The pooled absolute measurement errors ± the standard deviations of the depicted polyps with actual sizes ≤ 5 mm, 6-9 mm, and ≥ 10 mm were 1.9 ± 0.8 mm, 0.9 ± 1.2 mm, and 1.0 ± 1.4 mm, respectively. CONCLUSION: USVE is reliable for polyp detection and measurement in in vitro study. PMID:27022217
Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao
2016-03-18
Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems.
Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao
2016-01-01
Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems. PMID:26999129
An automatic eye detection and tracking technique for stereo video sequences
NASA Astrophysics Data System (ADS)
Paduru, Anirudh; Charalampidis, Dimitrios; Fouts, Brandon; Jovanovich, Kim
2009-05-01
Human-computer interfacing (HCI) describes a system or process with which two information processors, namely a human and a computer, attempt to exchange information. Computer-to-human (CtH) information transfer has been relatively effective through visual displays and sound devices. On the other hand, the human-tocomputer (HtC) interfacing avenue has yet to reach its full potential. For instance, the most common HtC communication means are the keyboard and mouse, which are already becoming a bottleneck in the effective transfer of information. The solution to the problem is the development of algorithms that allow the computer to understand human intentions based on their facial expressions, head motion patterns, and speech. In this work, we are investigating the feasibility of a stereo system to effectively determine the head position, including the head rotation angles, based on the detection of eye pupils.
Zero echo time MRI-only treatment planning for radiation therapy of brain tumors after resection.
Boydev, C; Demol, B; Pasquier, D; Saint-Jalmes, H; Delpon, G; Reynaert, N
2017-10-01
Using magnetic resonance imaging (MRI) as the sole imaging modality for patient modeling in radiation therapy (RT) is a challenging task due to the need to derive electron density information from MRI and construct a so-called pseudo-computed tomography (pCT) image. We have previously published a new method to derive pCT images from head T1-weighted (T1-w) MR images using a single-atlas propagation scheme followed by a post hoc correction of the mapped CT numbers using local intensity information. The purpose of this study was to investigate the performance of our method with head zero echo time (ZTE) MR images. To evaluate results, the mean absolute error in bins of 20 HU was calculated with respect to the true planning CT scan of the patient. We demonstrated that applying our method using ZTE MR images instead of T1-w improved the correctness of the pCT in case of bone resection surgery prior to RT (that is, an example of large anatomical difference between the atlas and the patient). Copyright © 2017. Published by Elsevier Ltd.
Transport of energy by ultraintense laser-generated electrons in nail-wire targets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, T.; Lawrence Livermore National Laboratory, Livermore, California 94550; Key, M. H.
2009-11-15
Nail-wire targets (20 {mu}m diameter copper wires with 80 {mu}m hemispherical head) were used to investigate energy transport by relativistic fast electrons generated in intense laser-plasma interactions. The targets were irradiated using the 300 J, 1 ps, and 2x10{sup 20} W{center_dot}cm{sup -2} Vulcan laser at the Rutherford Appleton Laboratory. A spherically bent crystal imager, a highly ordered pyrolytic graphite spectrometer, and single photon counting charge-coupled device gave absolute Cu K{alpha} measurements. Results show a concentration of energy deposition in the head and an approximately exponential fall-off along the wire with about 60 {mu}m 1/e decay length due to resistive inhibition.more » The coupling efficiency to the wire was 3.3{+-}1.7% with an average hot electron temperature of 620{+-}125 keV. Extreme ultraviolet images (68 and 256 eV) indicate additional heating of a thin surface layer of the wire. Modeling using the hybrid E-PLAS code has been compared with the experimental data, showing evidence of resistive heating, magnetic trapping, and surface transport.« less
The Herschel Multi-Tiered Extragalactic Survey: SPIRE-mm Photometric Redshifts
NASA Technical Reports Server (NTRS)
Roseboom, I. G.; Ivison, R. J.; Greve, T. R.; Amblard, A.; Arumugam, V.; Auld, R.; Aussel, H.; Bethermin, M.; Blain, A.; Block, J.;
2012-01-01
We investigate the potential of submm-mm and submm-mm-radio photometric redshifts using a sample of mm-selected sources as seen at 250, 350 and 500 micron by the SPIRE instrument on Herschel. From a sample of 63 previously identified mm sources with reliable radio identifications in the Great Observatories Origins Deep Survey North and Lockman Hole North fields, 46 (73 per cent) are found to have detections in at least one SPIRE band. We explore the observed submm/mm color evolution with redshift, finding that the colors of mm sources are adequately described by a modified blackbody with constant optical depth Tau = (Nu/nu(sub 0))(exp Beta), where Beta = +1.8 and nu(sub 0) = c/100 micron. We find a tight correlation between dust temperature and IR luminosity. Using a single model of the dust temperature and IR luminosity relation, we derive photometric redshift estimates for the 46 SPIRE-detected mm sources. Testing against the 22 sources with known spectroscopic or good quality optical/near-IR photometric redshifts, we find submm/mm photometric redshifts offer a redshift accuracy of (absolute value of Delta sub (z))/(1 + z) = 0.16 (absolute value of Delta sub (z)) = 0.51). Including constraints from the radio-far-IR correlation, the accuracy is improved to (absolute value of Delta sub (z))/(1 + z) = 0.14 (((absolute value of Delta sub (z))) = 0.45). We estimate the redshift distribution of mm-selected sources finding a significant excess at Z > 3 when compared to approx 8S0 micron selected samples.
NASA Astrophysics Data System (ADS)
Billaud, Pierre; Marhaba, Salem; Grillet, Nadia; Cottancin, Emmanuel; Bonnet, Christophe; Lermé, Jean; Vialle, Jean-Louis; Broyer, Michel; Pellarin, Michel
2010-04-01
This article describes a high sensitivity spectrophotometer designed to detect the overall extinction of light by a single nanoparticle (NP) in the 10-4-10-5 relative range, using a transmission measurement configuration. We focus here on the simple and low cost scheme where a white lamp is used as a light source, permitting easy and broadband extinction measurements (300-900 nm). Using a microscope, in a confocal geometry, an increased sensitivity is reached thanks to a modulation of the NP position under the light spot combined with lock-in detection. Moreover, it is shown that this technique gives access to the absolute extinction cross-sections of the single NP provided that the incident electromagnetic field distribution experienced by the NP is accurately characterized. In this respect, an experimental procedure to characterize the light spot profile in the focal plane, using a reference NP as a probe, is also laid out. The validity of this approach is discussed and confirmed by comparing experimental intensity distributions to theoretical calculations taking into account the vector character of the tightly focused beam. The calibration procedure permitting to obtain the absolute extinction cross-section of the probed NP is then fully described. Finally, the force of the present technique is illustrated through selected examples concerning spherical and slightly elongated gold and silver NPs. Absolute extinction measurements are found to be in good consistency with the NP size and shape independently obtained from transmission electron microscopy, showing that spatial modulation spectroscopy is a powerful tool to get an optical fingerprint of the NP.
Wang, Jian-zhong; Gao, Hong-yan; Wang, Kun-zheng; Zhou, Rong-xing; Li, Xiao-dong; Guo, Jun; Lv, Hui-cheng
2011-10-01
To investigate the effect of glucocorticoid on the expression levels of osteoprotegerin (OPG) and receptor activator of nuclear factor kappa B ligand (RANKL) mRNAs in rat femoral head and the antagonistic effect of Epimedium, and explore the mechanism of Epimedium in preventing glucocorticoid-induced femoral head necrosis. Forty-eight adult SD rats were randomized into glucocorticoid group, Epimedium group and control group. In the former two groups, the rats received intramuscular injection of 12.5 mg prednisolone twice a week, and in Epimedium group, additional 1 ml/100 g aqueous Epimedium extract (equivalent to 0.1 g/ml of the crude drug) was administered intragastrically once daily. The control group received only intramuscular saline injection. After 4 weeks of treatment, osteonecrosis of the left femoral head was detected by HE staining, and the right femoral head was sampled for detection of OPG and RANKL mRNA expressions using real-time quantitative PCR. In glucocorticoid, Epimedium and control groups, the mortality rate of the rats was 12.5% (2/16), 6.25% (1/16), 0 (0/16), and femoral head necrosis occurred at a rate of 71.43% (10/14), 26.67% (4/15), and 0 (0/16), respectively. In glucocorticoid group, the expression level of OPG mRNA was significantly lower, RANKL expression significantly higher, and OPG/RANKL ratio significantly lower than those in Epimedium and control groups (P<0.05). OPG, RANKL and their ratios showed no significant differences between Epimedium group and the control group. Epimedium can prevent glucocorticoid-induced femoral head necrosis probably by antagonizing glucocorticiod-induced abnormal expressions of OPG and RANKL mRNA.
Go ahead, grow a head! A planarian's guide to anterior regeneration
2016-01-01
Abstract The unique ability of some planarian species to regenerate a head de novo, including a functional brain, provides an experimentally accessible system in which to study the mechanisms underlying regeneration. Here, we summarize the current knowledge on the key steps of planarian head regeneration (head‐versus‐tail decision, anterior pole formation and head patterning) and their molecular and cellular basis. Moreover, instructive properties of the anterior pole as a putative organizer and in coordinating anterior midline formation are discussed. Finally, we highlight that regeneration initiation occurs in a two‐step manner and hypothesize that wound‐induced and existing positional cues interact to detect tissue loss and together determine the appropriate regenerative outcomes. PMID:27606065
USDA-ARS?s Scientific Manuscript database
Fusarium Head Blight is a worldwide disease of small cereals grains such as wheat. The disease is food safety concern because it produces the metabolite, deoxynivalenol (DON), which is moderately toxic to humans and non-ruminant animals. The current study was implemented to develop more efficient me...
Alarm Pheromones of the Ant Atta Texana
John C. Moser; R. C. Brownlee; R. Silverstein
1968-01-01
Methyl-3-heptanone (0.59 μg/head) and 2-heptanone (0.14 μg/head) are the main volatile components of the mandibular glands of major workers. In the laboratory, worker ants detected and were attracted by 4-methyl-3-heptanone at a concentration of 5.7 x 10-13 g/cm3 (2.7 x 107 molecules...
Ziegler, Ronny; Brendel, Bernhard; Rinneberg, Herbert; Nielsen, Tim
2009-01-21
Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and model how detection sensitivity depends on breast compression and lesion fluorescence contrast. Our investigation shows that lesion detection is limited by relative noise in slab geometry and by absolute noise in cup geometry.
Mirsky, David M; Shekdar, Karuna V; Bilaniuk, Larissa T
2012-08-01
Abnormalities of the fetal head and neck may be seen in isolation or in association with central nervous system abnormalities, chromosomal abnormalities, and syndromes. Magnetic resonance imaging (MRI) plays an important role in detecting associated abnormalities of the brain as well as in evaluating for airway obstruction that may impact prenatal management and delivery planning. This article provides an overview of the common indications for MRI of the fetal head and neck, including abnormalities of the fetal skull and face, masses of the face and neck, and fetal goiter. Copyright © 2012 Elsevier Inc. All rights reserved.
Anchoring effects in the judgment of confidence: semantic or numeric priming?
Carroll, Steven R; Petrusic, William M; Leth-Steensen, Craig
2009-02-01
Over the last decade, researchers have debated whether anchoring effects are the result of semantic or numeric priming. The present study tested both hypotheses. In four experiments involving a sensory detection task, participants first made a relative confidence judgment by deciding whether they were more or less confident than an anchor value in the correctness of their decision. Subsequently, they expressed an absolute level of confidence. In two of these experiments, the relative confidence anchor values represented the midpoints between the absolute confidence scale values, which were either explicitly numeric or semantic, nonnumeric representations of magnitude. In two other experiments, the anchor values were drawn from a scale modally different from that used to express the absolute confidence (i.e., nonnumeric and numeric, respectively, or vice versa). Regardless of the nature of the anchors, the mean confidence ratings revealed anchoring effects only when the relative and absolute confidence values were drawn from identical scales. Together, the results of these four experiments limit the conditions under which both numeric and semantic priming would be expected to lead to anchoring effects.
Ketcha, M D; de Silva, T; Han, R; Uneri, A; Goerres, J; Jacobson, M; Vogt, S; Kleinszig, G; Siewerdsen, J H
2017-02-11
In image-guided procedures, image acquisition is often performed primarily for the task of geometrically registering information from another image dataset, rather than detection / visualization of a particular feature. While the ability to detect a particular feature in an image has been studied extensively with respect to image quality characteristics (noise, resolution) and is an ongoing, active area of research, comparatively little has been accomplished to relate such image quality characteristics to registration performance. To establish such a framework, we derived Cramer-Rao lower bounds (CRLB) for registration accuracy, revealing the underlying dependencies on image variance and gradient strength. The CRLB was analyzed as a function of image quality factors (in particular, dose) for various similarity metrics and compared to registration accuracy using CT images of an anthropomorphic head phantom at various simulated dose levels. Performance was evaluated in terms of root mean square error (RMSE) of the registration parameters. Analysis of the CRLB shows two primary dependencies: 1) noise variance (related to dose); and 2) sum of squared image gradients (related to spatial resolution and image content). Comparison of the measured RMSE to the CRLB showed that the best registration method, RMSE achieved the CRLB to within an efficiency factor of 0.21, and optimal estimators followed the predicted inverse proportionality between registration performance and radiation dose. Analysis of the CRLB for image registration is an important step toward understanding and evaluating an intraoperative imaging system with respect to a registration task. While the CRLB is optimistic in absolute performance, it reveals a basis for relating the performance of registration estimators as a function of noise content and may be used to guide acquisition parameter selection (e.g., dose) for purposes of intraoperative registration.
The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors.
Rangel, Alejandra; Palte, Gesa; Dunscombe, Peter
2010-07-01
Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. 9 head and neck (H&N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets (+/- 1 mm in two banks, +/- 0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H&N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.
Finding the most accurate method to measure head circumference for fetal weight estimation.
Schmidt, Ulrike; Temerinac, Dunja; Bildstein, Katharina; Tuschy, Benjamin; Mayer, Jade; Sütterlin, Marc; Siemer, Jörn; Kehl, Sven
2014-07-01
Accurate measurement of fetal head biometry is important for fetal weight estimation (FWE) and is therefore an important prognostic parameter for neonatal morbidity and mortality and a valuable tool for determining the further obstetric management. Measurement of the head circumference (HC) in particular is employed in many commonly used weight equations. The aim of the present study was to find the most accurate method to measure head circumference for fetal weight estimation. This prospective study included 481 term pregnancies. Inclusion criteria were a singleton pregnancy and ultrasound examination with complete fetal biometric parameters within 3 days of delivery, and an absence of structural or chromosomal malformations. Different methods were used for ultrasound measurement of the HC (ellipse-traced, ellipse-calculated, and circle-calculated). As a reference method, HC was also determined using a measuring tape immediately after birth. FWE was carried out with Hadlock formulas, including either HC or biparietal diameter (BPD), and differences were compared using percentage error (PE), absolute percentage error (APE), limits of agreement (LOA), and cumulative distribution. The ellipse-traced method showed the best results for FWE among all of the ultrasound methods assessed. It had the lowest median APE and the narrowest LOA. With regard to the cumulative distribution, it included the largest number of cases at a discrepancy level of ±10%. The accuracy of BPD was similar to that of the ellipse-traced method when it was used instead of HC for weight estimation. Differences between the three techniques for calculating HC were small but significant. For clinical use, the ellipse-traced method should be recommended. However, when BPD is used instead of HC for FWE, the accuracy is similar to that of the ellipse-traced method. The BPD might therefore be a good alternative to head measurements in estimating fetal weight. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Chen, Hongda; Zucknick, Manuela; Werner, Simone; Knebel, Phillip; Brenner, Hermann
2015-07-15
Novel noninvasive blood-based screening tests are strongly desirable for early detection of colorectal cancer. We aimed to conduct a head-to-head comparison of the diagnostic performance of 92 plasma-based tumor-associated protein biomarkers for early detection of colorectal cancer in a true screening setting. Among all available 35 carriers of colorectal cancer and a representative sample of 54 men and women free of colorectal neoplasms recruited in a cohort of screening colonoscopy participants in 2005-2012 (N = 5,516), the plasma levels of 92 protein biomarkers were measured. ROC analyses were conducted to evaluate the diagnostic performance. A multimarker algorithm was developed through the Lasso logistic regression model and validated in an independent validation set. The .632+ bootstrap method was used to adjust for the potential overestimation of diagnostic performance. Seventeen protein markers were identified to show statistically significant differences in plasma levels between colorectal cancer cases and controls. The adjusted area under the ROC curves (AUC) of these 17 individual markers ranged from 0.55 to 0.70. An eight-marker classifier was constructed that increased the adjusted AUC to 0.77 [95% confidence interval (CI), 0.59-0.91]. When validating this algorithm in an independent validation set, the AUC was 0.76 (95% CI, 0.65-0.85), and sensitivities at cutoff levels yielding 80% and 90% specificities were 65% (95% CI, 41-80%) and 44% (95% CI, 24-72%), respectively. The identified profile of protein biomarkers could contribute to the development of a powerful multimarker blood-based test for early detection of colorectal cancer. ©2015 American Association for Cancer Research.
Inata, Hiroki; Araki, Fujio; Kuribayashi, Yuta; Hamamoto, Yasushi; Nakayama, Shigeki; Sodeoka, Noritaka; Kiriyama, Tetsukazu; Nishizaki, Osamu
2015-09-21
This study developed a dedicated real-time monitoring system to detect intra-fractional head motion in intracranial radiotherapy using pressure sensors. The dedicated real-time monitoring system consists of pressure sensors with a thickness of 0.6 mm and a radius of 9.1 mm, a thermoplastic mask, a vacuum pillow, and a baseplate. The four sensors were positioned at superior-inferior and right-left sides under the occipital area. The sampling rate of pressure sensors was set to 5 Hz. First, we confirmed that the relationship between the force and the displacement of the vacuum pillow follows Hook's law. Next, the spring constant for the vacuum pillow was determined from the relationship between the force given to the vacuum pillow and the displacement of the head, detected by Cyberknife target locating system (TLS) acquisitions in clinical application. Finally, the accuracy of our system was evaluated by using the 2 × 2 confusion matrix. The regression lines between the force, y, and the displacement, x, of the vacuum pillow were given by y = 3.8x, y = 4.4x, and y = 5.0x when the degree of inner pressure was -12 kPa,-20 kPa, and -27 kPa, respectively. The spring constant of the vacuum pillow was 1.6 N mm(-1) from the 6D positioning data of a total of 2999 TLS acquisitions in 19 patients. Head motions of 1 mm, 1.5 mm, and 2 mm were detected in real-time with the accuracies of 67%, 84%, and 89%, respectively. Our system can detect displacement of the head continuously during every interval of TLS with a resolution of 1-2 mm without any radiation exposure.
Hair analysis for long-term monitoring of buprenorphine intake in opiate withdrawal.
Pirro, Valentina; Fusari, Ivana; Di Corcia, Daniele; Gerace, Enrico; De Vivo, Enrico; Salomone, Alberto; Vincenti, Marco
2014-12-01
Buprenorphine (BUP) is a psychoactive pharmaceutical drug largely used to treat opiate addiction. Short-term therapeutic monitoring is supported by toxicological analysis of blood and urine samples, whereas long-term monitoring by means of hair analysis is rarely used. Aim of this work was to develop and validate a highly sensitive ultrahigh-performance liquid chromatography tandem mass spectrometry method to detect BUP and norbuprenorphine (NBUP) in head hair. Interindividual correlation between oral dosage of BUP and head hair concentration was investigated. Furthermore, an intra-individual study by means of segmental analysis was performed on subjects with variable maintenance dosage. Hair samples from a population of 79 patients in treatment for opiate addiction were analyzed. The validated ultrahigh-performance liquid chromatography tandem mass spectrometry protocol allowed to obtain limits of detection and quantification at 0.6 and 2.2 pg/mg for BUP and 5.0 and 17 pg/mg for NBUP, respectively. Validation criteria were satisfied, assuring selective analyte identification, high detection capability, and precise and accurate quantification. Significant positive correlation was found between constant oral BUP dosage (1-32 mg/d) and the summed up head hair concentrations of BUP and NBUP. Nevertheless, substantial interindividual variability limits the chance to predict the oral dosage taken by each subject from the measured concentrations in head hair. In contrast, strong correlation was observed in the results of intra-individual segmental analysis, which proved reliable to detect oral dosage variations during therapy. Remarkably, all hair samples yielded BUP concentrations higher than 10 pg/mg, even when the lowest dosage was administered. Thus, these results support the selection of 10 pg/mg as a cutoff value.
The patterns of melanoma presentation in Rijeka region.
Pavlović-Ružić, Ira; Jonjić, Nives; Zamolo, Gordana; Zuvić-Butorac, Marta; Katunarić, Miljenko; Pečanić, Sanja
2013-01-01
There is a global rising incidence of melanoma. For different reasons, the patterns of the incidence, appearance, gender, anatomical distribution and outcome vary among different geographic areas. Screening programs have led to better early detection of melanoma in Australia and some world areas. National Cancer Registry and practice data show the incidence in Croatia to be constantly rising. Despite public education programs about early detection, at clinical departments there are still many new advanced stage melanoma patients. We analyzed data on 157 patients treated and followed up for 10 years for T1b-T4aN0 skin melanoma. There was a difference in anatomical distribution of melanoma lesions in correlation with patient age (ANOVA test, F=3.51, p=0.009). A higher prevalence of shoulder melanoma was found in young people and of head/neck melanoma in the elderly (post-hoc Sheffe test, p=0.038). T4 lesions were more commonly found in men and T1 mainly in women (Pearson χ(2)-test, χ(2)=12.08, p=0.016). There was no difference in Clark level, but a significantly higher Breslow stage was found in men (t=-2.52, p=0.013). Men were much more prone to have head and neck, body and shoulder melanoma, whereas women had more melanoma on their legs and arms. Clark and Breslow levels were strongly correlated in leg melanoma; head localization showed no correlation at all. In conclusion, more attention should be devoted to improve the results in melanoma detection in men, especially considering the prevalence of body (back) and head/neck localizations, sometimes not readily accessible for visual detection. The pattern of distribution also pointed to the need for more attention to pay to shoulder melanoma in younger people.
Perov, Alexander; Belgovskiy, Alexander I.; Mirzabekov, Andrei D.
2001-01-01
A biochip scanner device used to detect and acquire fluorescence signal data from biological microchips or biochips and method of use are provided. The biochip scanner device includes a laser for emitting a laser beam. A modulator, such as an optical chopper modulates the laser beam. A scanning head receives the modulated laser beam and a scanning mechanics coupled to the scanning head moves the scanning head relative to the biochip. An optical fiber delivers the modulated laser beam to the scanning head. The scanning head collects the fluorescence light from the biochip, launches it into the same optical fiber, which delivers the fluorescence into a photodetector, such as a photodiode. The biochip scanner device is used in a row scanning method to scan selected rows of the biochip with the laser beam size matching the size of the immobilization site.
NASA Astrophysics Data System (ADS)
Vest, Robert E.; Coplan, Michael A.; Clark, Charles W.
Far ultraviolet (FUV) scintillation of noble gases is used in dark matter and neutrino research and in neutron detection. Upon collisional excitation, noble gas atoms recombine into excimer molecules that decay by FUV emission. Direct detection of FUV is difficult. Another approach is to convert it to visible light using a wavelength-shifting medium. One such medium, tetraphenyl butadiene (TPB) can be vapor-deposited on substrates. Thus the quality of thin TPB films can be tightly controlled. We have measured the absolute efficiency of FUV-to-visible conversion by 1 μm-thick TPB films vs. FUV wavelengths between 130 and 300 nm, with 1 nm resolution. The energy efficiency of FUV to visible conversion varies between 1% and 5%. We make comparisons with other recent results. Work performed at the NIST SURF III Synchrotron Ultraviolet Radiation Facility,.
Herrmann, H W; Kim, Y H; Young, C S; Fatherley, V E; Lopez, F E; Oertel, J A; Malone, R M; Rubery, M S; Horsfield, C J; Stoeffl, W; Zylstra, A B; Shmayda, W T; Batha, S H
2014-11-01
A new Gas Cherenkov Detector (GCD) with low-energy threshold and high sensitivity, currently known as Super GCD (or GCD-3 at OMEGA), is being developed for use at the OMEGA Laser Facility and the National Ignition Facility (NIF). Super GCD is designed to be pressurized to ≤400 psi (absolute) and uses all metal seals to allow the use of fluorinated gases inside the target chamber. This will allow the gamma energy threshold to be run as low at 1.8 MeV with 400 psi (absolute) of C2F6, opening up a new portion of the gamma ray spectrum. Super GCD operating at 20 cm from TCC will be ∼400 × more efficient at detecting DT fusion gammas at 16.7 MeV than the Gamma Reaction History diagnostic at NIF (GRH-6m) when operated at their minimum thresholds.
Cold atomic hydrogen in the inner galaxy
NASA Technical Reports Server (NTRS)
Dickey, J. M.; Garwood, R. W.
1986-01-01
The VLA is used to measure 21 cm absorption in directions with the absolute value of b less than 1 deg., the absolute value of 1 less than 25 deg. to probe the cool atomic gas in the inner galaxy. Abundant H I absorption is detected; typical lines are deep and narrow, sometimes blending in velocity with adjacent features. Unlike 21 cm emission not all allowed velocities are covered: large portions of the l-v diagram are optically thin. Although not similar to H I emission, the absorption shows a striking correspondence with CO emission in the inner galaxy: essentially every strong feature detected in one survey is seen in the other. The provisional conclusion is that in the inner galaxy most cool atomic gas is associated with molecular cloud complexes. There are few or no cold atomic clouds devoid of molecules in the inner galaxy, although these are common in the outer galaxy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, H; Jing, J; Xie, C
Purpose: To find effective setting methods to mitigate the irradiation injure in synchrotron radiation microangiography(SRA) by Monte Carlo simulation. Methods: A mouse 1-D head model and a segmented voxel mouse head phantom were simulated by EGSnrc/Dosxyznrc code to investigate the dose enhancement effect of the iodine contrast agent irradiated by a monochromatic synchrotron radiation(SR) source. The influence of, like iodine concentration (IC), vessel width and depth, with and without skull layer protection and the various incident X ray energies, were simulated. The dose enhancement effect and the absolute dose based on the segmented voxel mouse head phantom were evaluated. Results:more » The dose enhancement ratio depends little on the irradiation depth, but strongly on the IC, which is linearly increases with IC. The skull layer protection cannot be ignored in SRA, the 700µm thick skull could decrease 10% of the dose. The incident X-ray energy can significantly affact the dose. E.g. compared to the dose of 33.2keV for 50mgI/ml, the 32.7keV dose decreases 38%, whereas the dose of 33.7 keV increases 69.2%, and the variation will strengthen more with enhanced IC. The segmented voxel mouse head phantom also showed that the average dose enhancement effect and the maximal voxel dose per photon depends little on the iodine voxel volume ratio, but strongly on IC. Conclusion: To decrease dose damage in SRA, the high-Z contrast agent should be used as little as possible, and try to avoid radiating locally the injected position immediately after the contrast agent injection. The fragile vessel containing iodine should avoid closely irradiating. Avoiding irradiating through the no or thin skull region, or appending thin equivalent material from outside to protect is also a better method. As long as SRA image quality is ensured, using incident X-ray energy as low as possible.« less
Iorizzo, Dana B.; Riley, Meghan E.; Hayhoe, Mary; Huxlin, Krystel R.
2011-01-01
The present experiments aimed to characterize the visual performance of subjects with long-standing, unilateral cortical blindness when walking in a naturalistic, virtual environment. Under static, seated testing conditions, cortically blind subjects are known to exhibit compensatory eye movement strategies. However, they still complain of significant impairment in visual detection during navigation. To assess whether this is due to a change in compensatory eye movement strategy between sitting and walking, we measured eye and head movements in subjects asked to detect peripherally-presented, moving basketballs. When seated, cortically blind subjects detected ~80% of balls, while controls detected almost all balls. Seated blind subjects did not make larger head movements than controls, but they consistently biased their fixation distribution towards their blind hemifield. When walking, head movements were similar in the two groups, but the fixation bias decreased to the point that fixation distribution in cortically blind subjects became similar to that in controls - with one major exception: at the time of basketball appearance, walking controls looked primarily at the far ground, in upper quadrants of the virtual field of view; cortically blind subjects looked significantly more at the near ground, in lower quadrants of the virtual field. Cortically blind subjects detected only 58% of the balls when walking while controls detected ~90%. Thus, the adaptive gaze strategies adopted by cortically blind individuals as a compensation for their visual loss are strongest and most effective when seated and stationary. Walking significantly alters these gaze strategies in a way that seems to favor walking performance, but impairs peripheral target detection. It is possible that this impairment underlies the experienced difficulty of those with cortical blindness when navigating in real life. PMID:21414339
Iorizzo, Dana B; Riley, Meghan E; Hayhoe, Mary; Huxlin, Krystel R
2011-05-25
The present experiments aimed to characterize the visual performance of subjects with long-standing, unilateral cortical blindness when walking in a naturalistic, virtual environment. Under static, seated testing conditions, cortically blind subjects are known to exhibit compensatory eye movement strategies. However, they still complain of significant impairment in visual detection during navigation. To assess whether this is due to a change in compensatory eye movement strategy between sitting and walking, we measured eye and head movements in subjects asked to detect peripherally-presented, moving basketballs. When seated, cortically blind subjects detected ∼80% of balls, while controls detected almost all balls. Seated blind subjects did not make larger head movements than controls, but they consistently biased their fixation distribution towards their blind hemifield. When walking, head movements were similar in the two groups, but the fixation bias decreased to the point that fixation distribution in cortically blind subjects became similar to that in controls - with one major exception: at the time of basketball appearance, walking controls looked primarily at the far ground, in upper quadrants of the virtual field of view; cortically blind subjects looked significantly more at the near ground, in lower quadrants of the virtual field. Cortically blind subjects detected only 58% of the balls when walking while controls detected ∼90%. Thus, the adaptive gaze strategies adopted by cortically blind individuals as a compensation for their visual loss are strongest and most effective when seated and stationary. Walking significantly alters these gaze strategies in a way that seems to favor walking performance, but impairs peripheral target detection. It is possible that this impairment underlies the experienced difficulty of those with cortical blindness when navigating in real life. Copyright © 2011 Elsevier Ltd. All rights reserved.
A LEAST ABSOLUTE SHRINKAGE AND SELECTION OPERATOR (LASSO) FOR NONLINEAR SYSTEM IDENTIFICATION
NASA Technical Reports Server (NTRS)
Kukreja, Sunil L.; Lofberg, Johan; Brenner, Martin J.
2006-01-01
Identification of parametric nonlinear models involves estimating unknown parameters and detecting its underlying structure. Structure computation is concerned with selecting a subset of parameters to give a parsimonious description of the system which may afford greater insight into the functionality of the system or a simpler controller design. In this study, a least absolute shrinkage and selection operator (LASSO) technique is investigated for computing efficient model descriptions of nonlinear systems. The LASSO minimises the residual sum of squares by the addition of a 1 penalty term on the parameter vector of the traditional 2 minimisation problem. Its use for structure detection is a natural extension of this constrained minimisation approach to pseudolinear regression problems which produces some model parameters that are exactly zero and, therefore, yields a parsimonious system description. The performance of this LASSO structure detection method was evaluated by using it to estimate the structure of a nonlinear polynomial model. Applicability of the method to more complex systems such as those encountered in aerospace applications was shown by identifying a parsimonious system description of the F/A-18 Active Aeroelastic Wing using flight test data.
NASA Technical Reports Server (NTRS)
Lapson, L. B.; Timothy, J. G.
1976-01-01
Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morley, Steven
The PyForecastTools package provides Python routines for calculating metrics for model validation, forecast verification and model comparison. For continuous predictands the package provides functions for calculating bias (mean error, mean percentage error, median log accuracy, symmetric signed bias), and for calculating accuracy (mean squared error, mean absolute error, mean absolute scaled error, normalized RMSE, median symmetric accuracy). Convenience routines to calculate the component parts (e.g. forecast error, scaled error) of each metric are also provided. To compare models the package provides: generic skill score; percent better. Robust measures of scale including median absolute deviation, robust standard deviation, robust coefficient ofmore » variation and the Sn estimator are all provided by the package. Finally, the package implements Python classes for NxN contingency tables. In the case of a multi-class prediction, accuracy and skill metrics such as proportion correct and the Heidke and Peirce skill scores are provided as object methods. The special case of a 2x2 contingency table inherits from the NxN class and provides many additional metrics for binary classification: probability of detection, probability of false detection, false alarm ration, threat score, equitable threat score, bias. Confidence intervals for many of these quantities can be calculated using either the Wald method or Agresti-Coull intervals.« less
The absolute threshold of cone vision
Koeing, Darran; Hofer, Heidi
2013-01-01
We report measurements of the absolute threshold of cone vision, which has been previously underestimated due to sub-optimal conditions or overly strict subjective response criteria. We avoided these limitations by using optimized stimuli and experimental conditions while having subjects respond within a rating scale framework. Small (1′ fwhm), brief (34 msec), monochromatic (550 nm) stimuli were foveally presented at multiple intensities in dark-adapted retina for 5 subjects. For comparison, 4 subjects underwent similar testing with rod-optimized stimuli. Cone absolute threshold, that is, the minimum light energy for which subjects were just able to detect a visual stimulus with any response criterion, was 203 ± 38 photons at the cornea, ∼0.47 log units lower than previously reported. Two-alternative forced-choice measurements in a subset of subjects yielded consistent results. Cone thresholds were less responsive to criterion changes than rod thresholds, suggesting a limit to the stimulus information recoverable from the cone mosaic in addition to the limit imposed by Poisson noise. Results were consistent with expectations for detection in the face of stimulus uncertainty. We discuss implications of these findings for modeling the first stages of human cone vision and interpreting psychophysical data acquired with adaptive optics at the spatial scale of the receptor mosaic. PMID:21270115
DOE Office of Scientific and Technical Information (OSTI.GOV)
Douglas W. Akers; Edwin A. Harvego
2012-08-01
This paper presents the results of a study to evaluate the feasibility of remotely detecting and quantifying fuel relocation from the core to the lower head, and to regions outside the reactor vessel primary containment of the Fukushima 1-3 reactors. The goals of this study were to determine measurement conditions and requirements, and to perform initial radiation transport sensitivity analyses for several potential measurement locations inside the reactor building. The radiation transport sensitivity analyses were performed based on reactor design information for boiling water reactors (BWRs) similar to the Fukushima reactors, ORIGEN2 analyses of 3-cycle BWR fuel inventories, and datamore » on previously molten fuel characteristics from TMI- 2. A 100 kg mass of previously molten fuel material located on the lower head of the reactor vessel was chosen as a fuel interrogation sensitivity target. Two measurement locations were chosen for the transport analyses, one inside the drywell and one outside the concrete biological shield surrounding the drywell. Results of these initial radiation transport analyses indicate that the 100 kg of previously molten fuel material may be detectable at the measurement location inside the drywell, but that it is highly unlikely that any amount of fuel material inside the RPV will be detectable from a location outside the concrete biological shield surrounding the drywell. Three additional fuel relocation scenarios were also analyzed to assess detection sensitivity for varying amount of relocated material in the lower head of the reactor vessel, in the control rods perpendicular to the detector system, and on the lower head of the drywell. Results of these analyses along with an assessment of background radiation effects and a discussion of measurement issues, such as the detector/collimator design, are included in the paper.« less
Multimedia systems in ultrasound image boundary detection and measurements
NASA Astrophysics Data System (ADS)
Pathak, Sayan D.; Chalana, Vikram; Kim, Yongmin
1997-05-01
Ultrasound as a medical imaging modality offers the clinician a real-time of the anatomy of the internal organs/tissues, their movement, and flow noninvasively. One of the applications of ultrasound is to monitor fetal growth by measuring biparietal diameter (BPD) and head circumference (HC). We have been working on automatic detection of fetal head boundaries in ultrasound images. These detected boundaries are used to measure BPD and HC. The boundary detection algorithm is based on active contour models and takes 32 seconds on an external high-end workstation, SUN SparcStation 20/71. Our goal has been to make this tool available within an ultrasound machine and at the same time significantly improve its performance utilizing multimedia technology. With the advent of high- performance programmable digital signal processors (DSP), the software solution within an ultrasound machine instead of the traditional hardwired approach or requiring an external computer is now possible. We have integrated our boundary detection algorithm into a programmable ultrasound image processor (PUIP) that fits into a commercial ultrasound machine. The PUIP provides both the high computing power and flexibility needed to support computationally-intensive image processing algorithms within an ultrasound machine. According to our data analysis, BPD/HC measurements made on PUIP lie within the interobserver variability. Hence, the errors in the automated BPD/HC measurements using the algorithm are on the same order as the average interobserver differences. On PUIP, it takes 360 ms to measure the values of BPD/HC on one head image. When processing multiple head images in sequence, it takes 185 ms per image, thus enabling 5.4 BPD/HC measurements per second. Reduction in the overall execution time from 32 seconds to a fraction of a second and making this multimedia system available within an ultrasound machine will help this image processing algorithm and other computer-intensive imaging applications become a practical tool for the sonographers in the feature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koivula, Lauri
Purpose: Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI reference images is feasible. This study aims to show that a MRI-only based RTP workflow is also feasible for proton beam therapy plans generated in MRI-based substitute computed tomography (sCT) images of the head and the pelvis. Methods: The sCTs were constructed for ten prostate cancer and ten brain tumor patients primarily by transforming the intensity valuesmore » of in-phase MR images to Hounsfield units (HUs) with a dual model HU conversion technique to enable heterogeneous tissue representation. HU conversion models for the pelvis were adopted from previous studies, further extended in this study also for head MRI by generating anatomical site-specific conversion models (a new training data set of ten other brain patients). This study also evaluated two other types of simplified sCT: dual bulk density (for bone and water) and homogeneous (water only). For every clinical case, intensity modulated proton therapy (IMPT) plans robustly optimized in standard planning CTs were calculated in sCT for evaluation, and vice versa. Overall dose agreement was evaluated using dose–volume histogram parameters and 3D gamma criteria. Results: In heterogeneous sCTs, the mean absolute errors in HUs were 34 (soft tissues: 13, bones: 92) and 42 (soft tissues: 9, bones: 97) in the head and in the pelvis, respectively. The maximum absolute dose differences relative to CT in the brain tumor clinical target volume (CTV) were 1.4% for heterogeneous sCT, 1.8% for dual bulk sCT, and 8.9% for homogenous sCT. The corresponding maximum differences in the prostate CTV were 0.6%, 1.2%, and 3.6%, respectively. The percentages of dose points in the head and pelvis passing 1% and 1 mm gamma index criteria were over 91%, 85%, and 38% with heterogeneous, dual bulk, and homogeneous sCTs, respectively. There were no significant changes to gamma index pass rates for IMPT plans first optimized in CT and then calculated in heterogeneous sCT versus IMPT plans first optimized in heterogeneous sCT and then calculated on standard CT. Conclusions: This study demonstrates that proton therapy dose calculations on heterogeneous sCTs are in good agreement with plans generated with standard planning CT. An MRI-only based RTP workflow is feasible in IMPT for brain tumors and prostate cancers.« less
Forman, Jason L; Segui-Gomez, Maria; Ash, Joseph H; Lopez-Valdes, Francisco J
2011-01-01
Understanding pediatric occupant postures can help researchers indentify injury risk factors, and provide information for prospective injury prediction. This study sought to observe lateral head positions and shoulder belt fit among older child automobile occupants during a scenario likely to result in sleeping - extended travel during the night. An observational, volunteer, in-transit study was performed with 30 pediatric rear-seat passengers, ages 7 to 14. Each was restrained by a three-point seatbelt and was driven for seventy-five minutes at night. Ten subjects used a high-back booster seat, ten used a low-back booster seat, and ten used none (based on the subject height and weight). The subjects were recorded with a low-light video camera, and one frame was analyzed per each minute of video. The high-back booster group exhibited a statistically significant (p<0.05) decrease in the mean frequency of poor shoulder belt fit compared to the no-booster and low-back booster groups. The high-back booster group also exhibited statistically significant decreases in the 90(th) percentile of the absolute value of the relative lateral motion of the head. The low-back booster group did not result in statistically significant decreases in poor shoulder belt fit or lateral head motion compared to the no-booster group. These results are consistent with the presence of large lateral supports of the high-back booster which provided support to the head while sleeping, reducing voluntary lateral occupant motion and improving shoulder belt fit. Future work includes examining lap belt fit in-transit, and examining the effects of these observations on predicted injury risk.
Lazik, Andrea; Landgraeber, Stefan; Claßen, Tim; Kraff, Oliver; Lauenstein, Thomas C; Theysohn, Jens M
2015-10-01
To analyze remodeling processes after advanced core decompression (ACD) in patients with avascular femoral head necrosis by means of 3T MRI and to identify indicators for clinical outcome considering the defect size and characteristics of the bone graft and of the neighboring regeneration tissue. Thirty-four hips, with preexisting preoperative MRIs in 21 cases, were examined 1-34 months (mean 12.7) postoperatively by 3T MRI. The volume of necrosis was measured manually pre- and postoperatively to calculate absolute as well as percentage necrosis reduction. The signal intensity of the bone graft was quantified using a 4-point scale. Border phenomena between the bone graft and bone were described and classified into groups. Wilcoxon sign-rank test was used to identify correlations between the analyzed items and clinical signs of femoral head collapse after a mean follow-up time of 28.6 months (10.4-46.8). Mean percentage reduction of necrosis was significantly higher in asymptomatic patients (59.36%) compared to patients with signs of femoral head collapse (28.78%, p = 0.008). Signal intensity of the bone graft increased in T1w and T2w TIRM sequences over time after surgery and was significantly higher in asymptomatic patients. Five border phenomena between the bone graft and healthy bone were identified. Among them, the so-called "rail sign" representing three layers of remodeling tissue correlated with the histological observations. A variety of border phenomena representing remodeling processes have been described using 3T MRI. Beneath the percentage amount of necrosis reduction, we identified the signal intensity of the bone graft as an indicator for clinical outcome.
Forman, Jason L.; Segui-Gomez, Maria; Ash, Joseph H.; Lopez-Valdes, Francisco J.
2011-01-01
Understanding pediatric occupant postures can help researchers indentify injury risk factors, and provide information for prospective injury prediction. This study sought to observe lateral head positions and shoulder belt fit among older child automobile occupants during a scenario likely to result in sleeping - extended travel during the night. An observational, volunteer, in-transit study was performed with 30 pediatric rear-seat passengers, ages 7 to 14. Each was restrained by a three-point seatbelt and was driven for seventy-five minutes at night. Ten subjects used a high-back booster seat, ten used a low-back booster seat, and ten used none (based on the subject height and weight). The subjects were recorded with a low-light video camera, and one frame was analyzed per each minute of video. The high-back booster group exhibited a statistically significant (p<0.05) decrease in the mean frequency of poor shoulder belt fit compared to the no-booster and low-back booster groups. The high-back booster group also exhibited statistically significant decreases in the 90th percentile of the absolute value of the relative lateral motion of the head. The low-back booster group did not result in statistically significant decreases in poor shoulder belt fit or lateral head motion compared to the no-booster group. These results are consistent with the presence of large lateral supports of the high-back booster which provided support to the head while sleeping, reducing voluntary lateral occupant motion and improving shoulder belt fit. Future work includes examining lap belt fit in-transit, and examining the effects of these observations on predicted injury risk. PMID:22105378
Deep Learning-Based Gaze Detection System for Automobile Drivers Using a NIR Camera Sensor.
Naqvi, Rizwan Ali; Arsalan, Muhammad; Batchuluun, Ganbayar; Yoon, Hyo Sik; Park, Kang Ryoung
2018-02-03
A paradigm shift is required to prevent the increasing automobile accident deaths that are mostly due to the inattentive behavior of drivers. Knowledge of gaze region can provide valuable information regarding a driver's point of attention. Accurate and inexpensive gaze classification systems in cars can improve safe driving. However, monitoring real-time driving behaviors and conditions presents some challenges: dizziness due to long drives, extreme lighting variations, glasses reflections, and occlusions. Past studies on gaze detection in cars have been chiefly based on head movements. The margin of error in gaze detection increases when drivers gaze at objects by moving their eyes without moving their heads. To solve this problem, a pupil center corneal reflection (PCCR)-based method has been considered. However, the error of accurately detecting the pupil center and corneal reflection center is increased in a car environment due to various environment light changes, reflections on glasses surface, and motion and optical blurring of captured eye image. In addition, existing PCCR-based methods require initial user calibration, which is difficult to perform in a car environment. To address this issue, we propose a deep learning-based gaze detection method using a near-infrared (NIR) camera sensor considering driver head and eye movement that does not require any initial user calibration. The proposed system is evaluated on our self-constructed database as well as on open Columbia gaze dataset (CAVE-DB). The proposed method demonstrated greater accuracy than the previous gaze classification methods.
Deep Learning-Based Gaze Detection System for Automobile Drivers Using a NIR Camera Sensor
Naqvi, Rizwan Ali; Arsalan, Muhammad; Batchuluun, Ganbayar; Yoon, Hyo Sik; Park, Kang Ryoung
2018-01-01
A paradigm shift is required to prevent the increasing automobile accident deaths that are mostly due to the inattentive behavior of drivers. Knowledge of gaze region can provide valuable information regarding a driver’s point of attention. Accurate and inexpensive gaze classification systems in cars can improve safe driving. However, monitoring real-time driving behaviors and conditions presents some challenges: dizziness due to long drives, extreme lighting variations, glasses reflections, and occlusions. Past studies on gaze detection in cars have been chiefly based on head movements. The margin of error in gaze detection increases when drivers gaze at objects by moving their eyes without moving their heads. To solve this problem, a pupil center corneal reflection (PCCR)-based method has been considered. However, the error of accurately detecting the pupil center and corneal reflection center is increased in a car environment due to various environment light changes, reflections on glasses surface, and motion and optical blurring of captured eye image. In addition, existing PCCR-based methods require initial user calibration, which is difficult to perform in a car environment. To address this issue, we propose a deep learning-based gaze detection method using a near-infrared (NIR) camera sensor considering driver head and eye movement that does not require any initial user calibration. The proposed system is evaluated on our self-constructed database as well as on open Columbia gaze dataset (CAVE-DB). The proposed method demonstrated greater accuracy than the previous gaze classification methods. PMID:29401681
Vomiting--is this a good indication for CT head scans in patients with minor head injury?
Bainbridge, J; Khirwadkar, H; Hourihan, M D
2012-02-01
The National Institute for Health and Clinical Excellence head injury guidelines advise CT imaging within 1 h if there is more than one episode of vomiting post-head injury in adults and three or more episodes in children. Since the guideline publication, studies have found that, following head injury, vomiting alone is associated with an abnormal CT head scan in 13-45% of cases. CT head scan requests referred from the emergency department between 1 May 2009 and 30 April 2010 were retrospectively reviewed. Patients with vomiting as the sole indication for an "immediate" CT head scan performed within 1 h were included in the study. Reports produced by experienced neuroradiologists were reviewed and the detection of significant head injury was noted. There were 1264 CT head scans performed during our study period. 151 (124 adults, 27 children) were indicated owing to vomiting following head injury. 5 of the 124 adult scans and 1 of the 27 paediatric scans showed an abnormal finding, giving positive predictive values (PPV) of 4% and 3.7%, respectively. None of these patients required either acute or delayed neurosurgical intervention. In our experience, vomiting alone has a PPV of 4% for significant head injury in adults. However, none of these injuries were serious enough to warrant acute or delayed intervention. Given these findings, vomiting following head injury is a reasonable indication for a CT head scan; however, as none of the patients required acute intervention, we suggest that these scans do not usually need to be performed within 1 h of request.
NASA Astrophysics Data System (ADS)
Fazel Bakhsheshi, Mohammad; Diop, Mamadou; St Lawrence, Keith; Lee, Ting-Yim
2012-02-01
Hypothermia, in which the brain is cooled to 32-33 °C, has been shown to be neuroprotective for brain injury caused by hypoxia-ischemia, head trauma, or neonatal asphyxia. Neuroprotective effect of Hypothermia is partly due to suppression of brain metabolism and cerebral blood flow (CBF). The ability to measure CBF at the bedside provides a means of detecting, and thereby preventing, secondary ischemia during neuro intensive care before brain injury occurs. The purpose of the present study is to investigate the ability of a time-resolved near-infrared (TR-NIR) bolus-tracking method using indocyanine green as an intravascular flow tracer to measure CBF during cooling in a newborn animal model. For validation, CBF was independently measured by computed tomography (CT) perfusion. The results show a good agreement between CBF obtained with the two methods (R2 ~ 0.84, Δ ~ 5.84 ml. min -1.100 g -1, 32-38.5 °C), demonstrating the ability of the TR-NIR technique to non-invasively measure absolute CBF in-vivo during dynamic hypothermia. The TR-NIR technique reveals that CBF decreases from 54.3 +/- 5.4 ml. min -1.100 g -1, at normothermia (Tbrain of 38.5 °C), to 33.8 +/- 0.9 ml. min -1.100 g -1 at Tbrain of 32 °C during the hypothermia treatment.
Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.
Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm
2006-01-01
To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.
Synthetic Hounsfield units from spectral CT data
NASA Astrophysics Data System (ADS)
Bornefalk, Hans
2012-04-01
Beam-hardening-free synthetic images with absolute CT numbers that radiologists are used to can be constructed from spectral CT data by forming ‘dichromatic’ images after basis decomposition. The CT numbers are accurate for all tissues and the method does not require additional reconstruction. This method prevents radiologists from having to relearn new rules-of-thumb regarding absolute CT numbers for various organs and conditions as conventional CT is replaced by spectral CT. Displaying the synthetic Hounsfield unit images side-by-side with images reconstructed for optimal detectability for a certain task can ease the transition from conventional to spectral CT.
Dedhia, Raj C; Grandis, Jennifer R; Fontes, Paulo A; Johnson, Jonas T; Weissfeld, Joel
2012-03-01
At our institution, any liver transplant candidate with a recent history of smoking combined with daily use of alcohol prior to a 6-month sobriety period warrants formal evaluation by otolaryngology. Given the significant resource consumption and lack of evidence in support of this strategy, we sought to determine the effectiveness of these guidelines in detecting head and neck cancer. Retrospective review of clinical database and patient billing records. Under an institutional review board-approved protocol, a search was performed for patients seen at our institution's otolaryngology office from 1999 to 2010. This patient list was cross-matched with the patients evaluated for transplant at the University of Pittsburgh Starzl Transplantation Institute during the same timeframe. A search for the diagnosis of head and neck squamous cell carcinoma of the head and neck (HNC) among these patients was carried out through both a National Cancer Institute-affiliated clinical research registry and ICD-9 codes from billing records. Otolaryngology attending physicians were also asked to recall detection of HNC upon screening of this patient population. Of 581 patient evaluations performed by the otolaryngologist for HNC screening prior to liver transplantation from 1999 to 2009, one (0.17% of evaluations) case of HNC was detected. Given the consumption of resources required for this screening strategy and the limited yield, it appears that current screening guidelines are ineffective and need to be reconsidered. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.
Hassett, Michael J; Uno, Hajime; Cronin, Angel M; Carroll, Nikki M; Hornbrook, Mark C; Ritzwoller, Debra
2017-12-01
Recurrent cancer is common, costly, and lethal, yet we know little about it in community-based populations. Electronic health records and tumor registries contain vast amounts of data regarding community-based patients, but usually lack recurrence status. Existing algorithms that use structured data to detect recurrence have limitations. We developed algorithms to detect the presence and timing of recurrence after definitive therapy for stages I-III lung and colorectal cancer using 2 data sources that contain a widely available type of structured data (claims or electronic health record encounters) linked to gold-standard recurrence status: Medicare claims linked to the Cancer Care Outcomes Research and Surveillance study, and the Cancer Research Network Virtual Data Warehouse linked to registry data. Twelve potential indicators of recurrence were used to develop separate models for each cancer in each data source. Detection models maximized area under the ROC curve (AUC); timing models minimized average absolute error. Algorithms were compared by cancer type/data source, and contrasted with an existing binary detection rule. Detection model AUCs (>0.92) exceeded existing prediction rules. Timing models yielded absolute prediction errors that were small relative to follow-up time (<15%). Similar covariates were included in all detection and timing algorithms, though differences by cancer type and dataset challenged efforts to create 1 common algorithm for all scenarios. Valid and reliable detection of recurrence using big data is feasible. These tools will enable extensive, novel research on quality, effectiveness, and outcomes for lung and colorectal cancer patients and those who develop recurrence.
Video-Based Eye Tracking to Detect the Attention Shift: A Computer Classroom Context-Aware System
ERIC Educational Resources Information Center
Kuo, Yung-Lung; Lee, Jiann-Shu; Hsieh, Min-Chai
2014-01-01
Eye and head movements evoked in response to obvious visual attention shifts. However, there has been little progress on the causes of absent-mindedness so far. The paper proposes an attention awareness system that captures the conditions regarding the interaction of eye gaze and head pose under various attentional switching in computer classroom.…
Restricting the Time of Injury in Fatal Inflicted Head Injuries.
ERIC Educational Resources Information Center
Willman, Kristal Y.; Bank, David E.; Scenic, Melvin; Catwalk, David L.
1997-01-01
Review of the cases of 95 fatal head injuries in children found that brain swelling could be detected as early as 1 hour 17 minutes postinjury using computerized topography scans. Results also suggested that a reported history of a lucid interval in a case not involving an epidural hematoma is likely to be false and the injury probably inflicted.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyoden, Tomoaki, E-mail: kyouden@nc-toyama.ac.jp; Naruki, Shoji; Akiguchi, Shunsuke
Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensionalmore » space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.« less
Schmidt, Christina; Xhrouet, Marine; Hamacher, Manon; Delloye, Eric; LeGoff, Caroline; Cavalier, Etienne; Collette, Fabienne; Vandewalle, Gilles
2018-06-26
We aimed at assessing whether a head-mounted light therapy device, enriched in blue wavelengths, suppresses melatonin secretion and improves vigilant attention in the late evening hours. We also assessed whether using such light device is associated with discomfort and physiological stress. Seventeen healthy young participants (eight females) participated in a counterbalanced within-subject design during which they were exposed for 2 hr before habitual sleep time to a blue-enriched light (1500 lx) or to a lower intensity red-light (150 lx) control condition, using a new-generation light emitting diode (LED) head-mounted device. Compared to the red light control condition, blue-enriched light significantly reduced melatonin secretion and reaction times during a psychomotor vigilance task while no significant differences were detected in discomfort and cortisol levels. These results suggest that, compared to a control condition, blue-enriched light, delivered by a new-generation head-mounted device, elicits typical non-visual responses to light without detectable discomfort and physiological stress. They suggest that such devices might constitute an effective alternative to standard light boxes. © 2018 The Institute of Psychology, Chinese Academy of Sciences and John Wiley & Sons Australia, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paone, Jeffrey R; Bolme, David S; Ferrell, Regina Kay
Keeping a driver focused on the road is one of the most critical steps in insuring the safe operation of a vehicle. The Strategic Highway Research Program 2 (SHRP2) has over 3,100 recorded videos of volunteer drivers during a period of 2 years. This extensive naturalistic driving study (NDS) contains over one million hours of video and associated data that could aid safety researchers in understanding where the driver s attention is focused. Manual analysis of this data is infeasible, therefore efforts are underway to develop automated feature extraction algorithms to process and characterize the data. The real-world nature, volume,more » and acquisition conditions are unmatched in the transportation community, but there are also challenges because the data has relatively low resolution, high compression rates, and differing illumination conditions. A smaller dataset, the head pose validation study, is available which used the same recording equipment as SHRP2 but is more easily accessible with less privacy constraints. In this work we report initial head pose accuracy using commercial and open source face pose estimation algorithms on the head pose validation data set.« less
Gray, B G; Ichise, M; Chung, D G; Kirsh, J C; Franks, W
1992-01-01
The functional imaging modality has potential for demonstrating parenchymal abnormalities not detectable by traditional morphological imaging. Fifty-three patients with a remote history of traumatic brain injury (TBI) were studied with SPECT using 99mTc-hexamethylpropyleneamineoxime (HMPAO) and x-ray computed tomography (CT). Overall, 42 patients (80%) showed regional cerebral blood flow (rCBF) deficits by HMPAO SPECT, whereas 29 patients (55%) showed morphological abnormalities by CT. Out of 20 patients with minor head injury, 12 patients (60%) showed rCBF deficits and 5 patients (25%) showed CT abnormalities. Of 33 patients with major head injury, 30 patients (90%) showed rCBF deficits and 24 patients (72%) showed CT abnormalities. Thus, HMPAO SPECT was more sensitive than CT in detecting abnormalities in patients with a history of TBI, particularly in the minor head injury group. In the major head injury group, three patients showed localized cortical atrophy by CT and normal rCBF by HMPAO SPECT. In the evaluation of TBI patients, HMPAO SPECT is a useful technique to demonstrate regional brain dysfunction in the presence of morphological integrity as assessed by CT.
Magnetocardiogram measured by fundamental mode orthogonal fluxgate array
NASA Astrophysics Data System (ADS)
Karo, Hikaru; Sasada, Ichiro
2015-05-01
Magnetocardiography (MCG) of healthy volunteers has been measured by using a fundamental mode orthogonal fluxgate magnetometer array of 32 channels in a magnetic shielded room (MSR). Sensor heads, which are employed, consist of a 45 mm long U-shaped amorphous wire core and a 1000-turn solenoid pick-up coil of 30 mm in length and 3 mm in outer diameter. The excitation current of 100 kHz with large dc bias current is fed directly into wire cores, which are connected in series, whereas the signal detection circuit is provided to each of the sensor heads. A special technique to avoid mutual interaction between sensor heads is implemented, where all the sensor heads are excited synchronously by using a single ac source. A 2-D array having 32 sensors with 4 cm grid spacing was used to measure MCG signals inside an MSR. Measured data from each channel were first filtered (0.16-100 Hz pass band), then averaged for 2 min synchronously with electrocardiogram's peaks taken from both hands. Noise remaining after the average is about 1.8 pTrms for the band-width of 0.16-100 Hz. The QRS complex and the T-wave are clearly detected.
NASA Astrophysics Data System (ADS)
Zhao, Y.; Nelson, D. M.; Clegg, B. F.; Berry, J.; Hu, F.
2016-12-01
δ13C analysis of specific taxa or compounds is commonly used for investigating past environmental change, including methane dynamics in lakes. However, most analytical methods require large sample sizes, prohibiting routine analysis of fossils of individual taxa found in sediment deposits. For example, 10-100 individual head capsules of fossil midges are required for δ13C analysis using an elemental analyzer (EA) interfaced with an isotope-ratio mass spectrometer (IRMS). Here we present a new method that uses a spooling-wire microcombustion (SWiM) device interfaced with an IRMS for measuring δ13C values of carbon dissolved from individual head capsules of chitinous aquatic zooplankton. We extracted chitin (a major biochemical component of insect exoskeleton) from modern midge material obtained from four commercial suppliers. We first assessed the effects of sample treatments on carbon yields and δ13C values of dissolved chitin by varying the concentration of HCl used for dissolution, the duration of reaction in HCl, and the temperature of dissolution. We then investigated potential fractionation of carbon isotopes associated with chitin dissolution, by comparing δ13C values of dissolved chitin obtained via SWiM-IRMS with those from untreated head capsules obtained via a EA-IRMS. The average δ13C values of untreated head capsules varied between -25.1 and -30.1‰. Higher acid concentrations and temperatures, as well as longer reaction times, increased dissolution of carbon from the head capsules and the precision of δ13C values. For example, carbon yields from reaction of head capsules with 6N HCl at 25°C increased from 1 to 3 Vs as reaction times increased from 1 to 24 hours. Acid concentration and reaction time had the greatest influence on carbon yields and isotopic precision. The δ13C values of dissolved chitin mirrored the δ13C values of untreated head capsules with minimal offset of absolute values, which suggests no systematic fractionation associated with dissolution. Overall, these results indicate that carbon isotopic analysis of dissolved chitin using the SWiM-IRMS system offers a reliable new method to determine taxa-specific δ13C values for chitinous aquatic zooplankton. In ongoing work, we are applying this tool to reconstruct past methane dynamics in Arctic lakes during the Holocene.
Webster, Gareth J; Hardy, Mark J; Rowbottom, Carl G; Mackay, Ranald I
2008-04-16
The head and neck is a challenging anatomic site for intensity-modulated radiation therapy (IMRT), requiring thorough testing of planning and treatment delivery systems. Ideally, the phantoms used should be anatomically realistic, have radiologic properties identical to those of the tissues concerned, and allow for the use of a variety of devices to verify dose and dose distribution in any target or normaltissue structure. A phantom that approaches the foregoing characteristics has been designed and built; its specific purpose is verification for IMRT treatments in the head-andneck region. This semi-anatomic phantom, HANK, is constructed of Perspex (Imperial Chemical Industries, London, U.K.) and provides for the insertion of heterogeneities simulating air cavities in a range of fixed positions. Chamber inserts are manufactured to incorporate either a standard thimble ionization chamber (0.125 cm3: PTW, Freiburg, Germany) or a smaller PinPoint chamber (0.015 cm3: PTW), and measurements can be made with either chamber in a range of positions throughout the phantom. Coronal films can also be acquired within the phantom, and additional solid blocks of Perspex allow for transverse films to be acquired within the head region. Initial studies using simple conventional head-and-neck plans established the reproducibility of the phantom and the measurement devices to within the setup uncertainty of +/- 0.5 mm. Subsequent verification of 9 clinical head-and-neck IMRT plans demonstrated the efficacy of the phantom in making a range of patient-specific dose measurements in regions of dosimetric and clinical interest. Agreement between measured values and those predicted by the Pinnacle3 treatment planning system (Philips Medical Systems, Andover, MA) was found to be generally good, with a mean error on the calculated dose to each point of +0.2% (range: -4.3% to +2.2%; n = 9) for the primary planning target volume (PTV), -0.1% (range: -1.5% to +2.0%; n = 8) for the nodal PTV, and +0.0% (range: -1.8% to +4.3%, n = 9) for the spinal cord. The suitability of the phantom for measuring combined dose distributions using radiographic film was also evaluated. The phantom has proved to be a valuable tool in the development and implementation of clinical head-and-neck IMRT, allowing for accurate verification of absolute dose and dose distributions in regions of clinical and dosimetric interest.
Interpersonal Coordination of Head Motion in Distressed Couples
Hammal, Zakia; Cohn, Jeffrey F.; George, David T.
2015-01-01
In automatic emotional expression analysis, head motion has been considered mostly a nuisance variable, something to control when extracting features for action unit or expression detection. As an initial step toward understanding the contribution of head motion to emotion communication, we investigated the interpersonal coordination of rigid head motion in intimate couples with a history of interpersonal violence. Episodes of conflict and non-conflict were elicited in dyadic interaction tasks and validated using linguistic criteria. Head motion parameters were analyzed using Student’s paired t-tests; actor-partner analyses to model mutual influence within couples; and windowed cross-correlation to reveal dynamics of change in direction of influence over time. Partners’ RMS angular displacement for yaw and RMS angular velocity for pitch and yaw each demonstrated strong mutual influence between partners. Partners’ RMS angular displacement for pitch was higher during conflict. In both conflict and non-conflict, head angular displacement and angular velocity for pitch and yaw were strongly correlated, with frequent shifts in lead-lag relationships. The overall amount of coordination between partners’ head movement was more highly correlated during non-conflict compared with conflict interaction. While conflict increased head motion, it served to attenuate interpersonal coordination. PMID:26167256
Rotation of the stalk/neck and one head in a new crystal structure of the kinesin motor protein, Ncd
Yun, Mikyung; Bronner, C.Eric; Park, Cheon-Gil; Cha, Sun-Shin; Park, Hee-Won; Endow, Sharyn A.
2003-01-01
Molecular motors undergo conformational changes to produce force and move along cytoskeletal filaments. Structural changes have been detected in kinesin motors; however, further changes are expected because previous crystal structures are in the same or closely related conformations. We report here a 2.5 Å crystal structure of the minus-end kinesin, Ncd, with the coiled-coil stalk/neck and one head rotated by ∼75° relative to the other head. The two heads are asymmetrically positioned with respect to the stalk and show asymmetry of nucleotide state: one head is fully occupied, but the other is unstably bound to ADP. Unlike previous structures, our new atomic model can be fit into cryoelectron microscopy density maps of the motor attached to microtubules, where it appears to resemble a one-head-bound motor with the stalk rotated towards the minus end. Interactions between neck and motor core residues, observed in the head that moves with the stalk, are disrupted in the other head, permitting rotation of the stalk/neck. The rotation could represent a force-producing stroke that directs the motor to the minus end. PMID:14532111
Dove prism based rotating dual beam bidirectional Doppler OCT
Blatter, Cedric; Coquoz, Séverine; Grajciar, Branislav; Singh, Amardeep S. G.; Bonesi, Marco; Werkmeister, René M.; Schmetterer, Leopold; Leitgeb, Rainer A.
2013-01-01
Traditional Doppler OCT is highly sensitive to motion artifacts due to the dependence on the Doppler angle. This limits its accuracy in clinical practice. To overcome this limitation, we use a bidirectional dual beam technique equipped with a novel rotating scanning scheme employing a Dove prism. The volume is probed from two distinct illumination directions with variable controlled incidence plane, allowing for reconstruction of the true flow velocity at arbitrary vessel orientations. The principle is implemented with Swept Source OCT at 1060nm with 100,000 A-Scans/s. We apply the system to resolve pulsatile retinal absolute blood velocity by performing segment scans around the optic nerve head and circumpapillary scan time series. PMID:23847742
Intelligent fiber optic sensor for solution concentration examination
NASA Astrophysics Data System (ADS)
Borecki, Michal; Kruszewski, Jerzy
2003-09-01
This paper presents the working principles of intelligent fiber-optic intensity sensor used for solution concentration examination. The sensor head is the ending of the large core polymer optical fiber. The head works on the reflection intensity basis. The reflected signal level depends on Fresnel reflection and reflection on suspended matter when the head is submersed in solution. The sensor head is mounted on a lift. For detection purposes the signal includes head submerging, submersion, emerging and emergence is measured. This way the viscosity turbidity and refraction coefficient has an effect on measured signal. The signal forthcoming from head is processed electrically in opto-electronic interface. Then it is feed to neural network. The novelty of presented sensor is implementation of neural network that works in generalization mode. The sensor resolution depends on opto-electronic signal conversion precision and neural network learning accuracy. Therefore, the number and quality of points used for learning process is very important. The example sensor application for examination of liquid soap concentration in water is presented in the paper.
Genetic architecture of fusarium head blight resistance in four winter triticale populations.
Kalih, R; Maurer, H P; Miedaner, T
2015-03-01
Fusarium head blight (FHB) is a devastating disease that causes significant reductions in yield and quality in wheat, rye, and triticale. In triticale, knowledge of the genetic architecture of FHB resistance is missing but essential due to modern breeding requirements. In our study, four doubled-haploid triticale populations (N=120 to 200) were evaluated for resistance to FHB caused by artificial inoculation with Fusarium culmorum in four environments. DArT markers were used to genotype triticale populations. Seventeen quantitative trait loci (QTL) for FHB resistance were detected across all populations; six of them were derived from rye genome and located on chromosomes 4R, 5R, and 7R, which are here reported for the first time. The total cross-validated ratio of the explained phenotypic variance for all detected QTL in each population was 41 to 68%. In all, 17 QTL for plant height and 18 QTL for heading stage were also detected across all populations; 3 and 5 of them, respectively, were overlapping with QTL for FHB. In conclusion, FHB resistance in triticale is caused by a multitude of QTL, and pyramiding them contributes to higher resistance.
Detecting a Defective Casing Seal at the Top of a Bedrock Aquifer.
Richard, Sandra K; Chesnaux, Romain; Rouleau, Alain
2016-03-01
An improperly sealed casing can produce a direct hydraulic connection between two or more originally isolated aquifers with important consequences regarding groundwater quantity and quality. A recent study by Richard et al. (2014) investigated a monitoring well installed in a fractured rock aquifer with a defective casing seal at the soil-bedrock interface. A hydraulic short circuit was detected that produced some leakage between the rock and the overlying deposits. A falling-head permeability test performed in this well showed that the usual method of data interpretation is not valid in this particular case due to the presence of a piezometric error. This error is the direct result of the preferential flow originating from the hydraulic short circuit and the subsequent re-equilibration of the piezometric levels of both aquifers in the vicinity of the inlet and the outlet of the defective seal. Numerical simulations of groundwater circulation around the well support the observed impact of the hydraulic short circuit on the results of the falling-head permeability test. These observations demonstrate that a properly designed falling-head permeability test may be useful in the detection of defective casing seals. © 2015, National Ground Water Association.
NASA Astrophysics Data System (ADS)
Bloss, W. J.; Floquet, C.; Gravestock, T. J.; Heard, D. E.; Ingham, T.; Johnson, G. P.; Lee, J. D.
2003-04-01
Free-radicals are key intermediates that control the budgets of many trace gases, for example ozone, greenhouse gases and harmful pollutants. Measurement of radicals and comparison with model calculations constitutes an important test of our understanding of the underlying chemistry. There is a greater need for compact and lightweight instruments for the in situ measurement of free-radical species that are suitable for deployment from a number of field-platforms. A new field instrument has been developed that incorporates an all solid-state Nd:YAG pumped titanium sapphire laser that is capable of generating radiation at high pulse-repetition-frequency for the detection of OH, HO_2, NO and IO radicals in the atmosphere by laser induced fluorescence (LIF). The system offers advantages of wide wavelength tunability, compactness, low weight, greater long-term stability (fibre-optic delivery) and short warm-up time. The instrument was successfully deployed during 2002 in the NAMBLEX field campaign at Mace Head with detection limits for OH and HO_2 (measured simultaneously with laser operation at 308 nm) of 3.1 x 10^5 molecule cm-3 (0.012 ppt) and 2.6 x 10^6 molecule cm-3 (0.09 pptv) respectively. Diurnal profiles of OH have been recorded over a period of 5 weeks. NO controls the HO_2/OH ratio and is the critical parameter in the production of tropospheric ozone, yet measurements in the boundary layer are restricted to a single indirect technique based on chemiluminescent analysers. Measurements of NO in the atmosphere have been made by LIF using the new instrument operating at 226 nm, with absolute concentrations in good agreement with simultaneous measurements made using a commercial chemiluminescent analyser. Whilst operating at 445 nm, the instrument has detected the IO radical in the laboratory, with a projected detection limit that is well below previously measured atmospheric concentrations of IO. A second instrument to be deployed on an aircraft platform is currently being developed.
Srimurugan Pratheep, Neeraja; Madeleine, Pascal; Arendt-Nielsen, Lars
2018-04-25
Pressure pain threshold (PPT) and PPT maps are commonly used to quantify and visualize mechanical pain sensitivity. Although PPT's have frequently been reported from patients with knee osteoarthritis (KOA), the absolute and relative reliability of PPT assessments remain to be determined. Thus, the purpose of this study was to evaluate the test-retest relative and absolute reliability of PPT in KOA. For that purpose, intra- and interclass correlation coefficient (ICC) as well as the standard error of measurement (SEM) and the minimal detectable change (MDC) values within eight anatomical locations covering the most painful knee of KOA patients was measured. Twenty KOA patients participated in two sessions with a period of 2 weeks±3 days apart. PPT's were assessed over eight anatomical locations covering the knee and two remote locations over tibialis anterior and brachioradialis. The patients rated their maximum pain intensity during the past 24 h and prior to the recordings on a visual analog scale (VAS), and completed The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and PainDetect surveys. The ICC, SEM and MDC between the sessions were assessed. The ICC for the individual variability was expressed with coefficient of variance (CV). Bland-Altman plots were used to assess potential bias in the dataset. The ICC ranged from 0.85 to 0.96 for all the anatomical locations which is considered "almost perfect". CV was lowest in session 1 and ranged from 44.2 to 57.6%. SEM for comparison ranged between 34 and 71 kPa and MDC ranged between 93 and 197 kPa with a mean PPT ranged from 273.5 to 367.7 kPa in session 1 and 268.1-331.3 kPa in session 2. The analysis of Bland-Altman plot showed no systematic bias. PPT maps showed that the patients had lower thresholds in session 2, but no significant difference was observed for the comparison between the sessions for PPT or VAS. No correlations were seen between PainDetect and PPT and PainDetect and WOMAC. Almost perfect relative and absolute reliabilities were found for the assessment of PPT's for KOA patients. The present investigation implicates that PPT's is reliable for assessing pain sensitivity and sensitization in KOA patients.
[Role and responsibility of multimodal imaging in head and neck cancer].
Gõdény, Mária
2013-09-01
Hungary is first in head and neck cancer mortality in Europe in men and also in women. Head and neck (HN) is a difficult region, its anatomy and also pathology is very complex, various connection points exist between the sites which determine the extension of the disease. Diagnostic algorithms as well as imaging techniques have to be optimized to examine in standard manner. Like most other cancers, prognosis depends largely on the stage of the tumor. Accuracy of tumor detection and evaluation is very important because it affects treatment planning. As non-surgical organ-preserving therapeutic modalities (chemotherapy, chemoradiotherapy, targeted biological therapy) gain general acceptance, the importance of noninvasive diagnostic accuracy as well as radiologic evaluation of the extent of the tumor has increased. Clinical examinations including endoscopy should be combined with radiologic imaging to assess the precise local (T), regional nodal (N), and distant (M) extent of the tumor. Computed tomography (CT) and magnetic resonance imaging (MRI) have become basic tools in the diagnosis of head and neck tumors. They are both useful for assessing deep tumor extensions, able to detect changes missed by endoscopy. It has been shown that the primary determined tumor stage increases in up to 90% of patients after the results of cross sectional imaging. MRI is being increasingly used and has become the gold standard in head and neck cancer for staging, assessing tumor response, finding recurrent tumor and also for treatment planning in radiotherapy. The field strength of MRI scanners has been increasing to 1.5 T and now 3 T with better signal-to-noise ratio, higher resolution images and better tissue diagnosis. Functional MR techniques such as dynamic contrast enhanced MRI (DCE-MRI) and diffusion weighted MRI (DW-MRI) may provide further characterization. PET/CT is beneficial in detecting unsuspected metastatic nodes, distant disease and second primary tumor. PET/CT and MRI both appeared almost similarly accurate in the detection of an occult primary tumor. The effective management of patients depends highly on the competece of radiologists and requires close collaboration between clinical and surgical oncologists, diagnostic and therapeutic radiologists as well as pathologists.
A signal-detection-based diagnostic-feature-detection model of eyewitness identification.
Wixted, John T; Mickes, Laura
2014-04-01
The theoretical understanding of eyewitness identifications made from a police lineup has long been guided by the distinction between absolute and relative decision strategies. In addition, the accuracy of identifications associated with different eyewitness memory procedures has long been evaluated using measures like the diagnosticity ratio (the correct identification rate divided by the false identification rate). Framed in terms of signal-detection theory, both the absolute/relative distinction and the diagnosticity ratio are mainly relevant to response bias while remaining silent about the key issue of diagnostic accuracy, or discriminability (i.e., the ability to tell the difference between innocent and guilty suspects in a lineup). Here, we propose a signal-detection-based model of eyewitness identification, one that encourages the use of (and helps to conceptualize) receiver operating characteristic (ROC) analysis to measure discriminability. Recent ROC analyses indicate that the simultaneous presentation of faces in a lineup yields higher discriminability than the presentation of faces in isolation, and we propose a diagnostic feature-detection hypothesis to account for that result. According to this hypothesis, the simultaneous presentation of faces allows the eyewitness to appreciate that certain facial features (viz., those that are shared by everyone in the lineup) are non-diagnostic of guilt. To the extent that those non-diagnostic features are discounted in favor of potentially more diagnostic features, the ability to discriminate innocent from guilty suspects will be enhanced.
Imaging system for cardiac planar imaging using a dedicated dual-head gamma camera
Majewski, Stanislaw [Morgantown, VA; Umeno, Marc M [Woodinville, WA
2011-09-13
A cardiac imaging system employing dual gamma imaging heads co-registered with one another to provide two dynamic simultaneous views of the heart sector of a patient torso. A first gamma imaging head is positioned in a first orientation with respect to the heart sector and a second gamma imaging head is positioned in a second orientation with respect to the heart sector. An adjustment arrangement is capable of adjusting the distance between the separate imaging heads and the angle between the heads. With the angle between the imaging heads set to 180 degrees and operating in a range of 140-159 keV and at a rate of up to 500kHz, the imaging heads are co-registered to produce simultaneous dynamic recording of two stereotactic views of the heart. The use of co-registered imaging heads maximizes the uniformity of detection sensitivity of blood flow in and around the heart over the whole heart volume and minimizes radiation absorption effects. A normalization/image fusion technique is implemented pixel-by-corresponding pixel to increase signal for any cardiac region viewed in two images obtained from the two opposed detector heads for the same time bin. The imaging system is capable of producing enhanced first pass studies, bloodpool studies including planar, gated and non-gated EKG studies, planar EKG perfusion studies, and planar hot spot imaging.
NASA Astrophysics Data System (ADS)
Malmberg, Filip; Sandberg-Melin, Camilla; Söderberg, Per G.
2016-03-01
The aim of this project was to investigate the possibility of using OCT optic nerve head 3D information captured with a Topcon OCT 2000 device for detection of the shortest distance between the inner limit of the retina and the central limit of the pigment epithelium around the circumference of the optic nerve head. The shortest distance between these boundaries reflects the nerve fiber layer thickness and measurement of this distance is interesting for follow-up of glaucoma.
NASA Technical Reports Server (NTRS)
Cohn, R. B. (Inventor)
1983-01-01
A mounting device for securing a microphone pick up head flush with respect to the external surfaces of the skin of an aircraft for detecting shock waves passing thereover is described. The mount includes a sleeve mounted internally of the aircraft for capturing and supporting an electronics package having the microphone pick up head attached thereto in a manner such that the head is flush with the external surface of the aircraft skin and a pressure seal is established between the internal and external surfaces of the aircraft skin.
Rotary head type reproducing apparatus
Takayama, Nobutoshi; Edakubo, Hiroo; Kozuki, Susumu; Takei, Masahiro; Nagasawa, Kenichi
1986-01-01
In an apparatus of the kind arranged to reproduce, with a plurality of rotary heads, an information signal from a record bearing medium having many recording tracks which are parallel to each other with the information signal recorded therein and with a plurality of different pilot signals of different frequencies also recorded one by one, one in each of the recording tracks, a plurality of different reference signals of different frequencies are simultaneously generated. A tracking error is detected by using the different reference signals together with the pilot signals which are included in signals reproduced from the plurality of rotary heads.
Microwave Detection of Chemical Agents: A Review
1986-06-01
Health (NIOSH).8’l1 This instrument was designed to detect acetonitrile, acetaldehyde , acetone, carbonyl sulfide, ethanol, ethylene oxide , isopropyl...absolute temperature mij - the dipole matrix element connecting the upper and lower energy states vo = the absorption line center v - transition...from multiple reflections through the cell. The Q of a cavity is defined as the electro - magnetic energy in the cavity divided by the energy lost per
Detection of cracks beneath rivet heads via pulsed eddy current technique
NASA Astrophysics Data System (ADS)
Giguère, J. S. R.; Lepine, B. A.; Dubois, J. M. S.
2002-05-01
Improving the detectability of fatigue cracks under installed fasteners is one of the many goals of the aging aircraft nondestructive evaluation (NDE) community. The pulsed eddy current offers new capabilities to address this requirement. The aim of the paper is to evaluate the potential of this technique for detecting and quantifying notches under installed fasteners.
Witte, Anna Kristina; Fister, Susanne; Mester, Patrick; Schoder, Dagmar; Rossmanith, Peter
2016-11-01
Fast and reliable pathogen detection is an important issue for human health. Since conventional microbiological methods are rather slow, there is growing interest in detection and quantification using molecular methods. The droplet digital polymerase chain reaction (ddPCR) is a relatively new PCR method for absolute and accurate quantification without external standards. Using the Listeria monocytogenes specific prfA assay, we focused on the questions of whether the assay was directly transferable to ddPCR and whether ddPCR was suitable for samples derived from heterogeneous matrices, such as foodstuffs that often included inhibitors and a non-target bacterial background flora. Although the prfA assay showed suboptimal cluster formation, use of ddPCR for quantification of L. monocytogenes from pure bacterial cultures, artificially contaminated cheese, and naturally contaminated foodstuff was satisfactory over a relatively broad dynamic range. Moreover, results demonstrated the outstanding detection limit of one copy. However, while poorer DNA quality, such as resulting from longer storage, can impair ddPCR, internal amplification control (IAC) of prfA by ddPCR, that is integrated in the genome of L. monocytogenes ΔprfA, showed even slightly better quantification over a broader dynamic range. Graphical Abstract Evaluating the absolute quantification potential of ddPCR targeting Listeria monocytogenes prfA.
Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Volden, T.
2014-01-01
An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.
Penguin head movement detected using small accelerometers: a proxy of prey encounter rate.
Kokubun, Nobuo; Kim, Jeong-Hoon; Shin, Hyoung-Chul; Naito, Yasuhiko; Takahashi, Akinori
2011-11-15
Determining temporal and spatial variation in feeding rates is essential for understanding the relationship between habitat features and the foraging behavior of top predators. In this study we examined the utility of head movement as a proxy of prey encounter rates in medium-sized Antarctic penguins, under the presumption that the birds should move their heads actively when they encounter and peck prey. A field study of free-ranging chinstrap and gentoo penguins was conducted at King George Island, Antarctica. Head movement was recorded using small accelerometers attached to the head, with simultaneous monitoring for prey encounter or body angle. The main prey was Antarctic krill (>99% in wet mass) for both species. Penguin head movement coincided with a slow change in body angle during dives. Active head movements were extracted using a high-pass filter (5 Hz acceleration signals) and the remaining acceleration peaks (higher than a threshold acceleration of 1.0 g) were counted. The timing of head movements coincided well with images of prey taken from the back-mounted cameras: head movement was recorded within ±2.5 s of a prey image on 89.1±16.1% (N=7 trips) of images. The number of head movements varied largely among dive bouts, suggesting large temporal variations in prey encounter rates. Our results show that head movement is an effective proxy of prey encounter, and we suggest that the method will be widely applicable for a variety of predators.
Matiño-Soler, Eusebi; Esteller-More, Eduard; Martin-Sanchez, Juan-Carlos; Martinez-Sanchez, Jose-M; Perez-Fernandez, Nicolas
2015-03-01
To analyze vestibulo-ocular responses using the video head impulse test in the yaw axis. Prospective. Tertiary and university hospital. Two hundred twelve healthy subjects with no history of vestibular or neurologic impairment. Video head impulse test in the lateral semicircular canal plane. Vestibulo-ocular reflex (VOR) gain and appearance of refixation saccades (RSs) considering sex, age, and head impulse velocity and direction. Mean gain was 1.06 ± 0.07, and there were no differences between sexes. For all the impulses (n = 9,654; 4,947 rightward and 4,707 leftward), VOR gain decreased as head impulse velocity increased. When gain was evaluated by age and head velocity, it was steady until age 70 years for higher-velocity impulses and until age 90 years for lower-velocity head impulses. RSs were detected in 52 subjects, occurring after impulses to both sides of the head in 22 of these subjects. The number of subjects with RSs was significantly higher after age 71 years, and velocity was correlated, not with age, but with head impulse velocity. VOR gain was stable until age 90 years and thereafter dropped. However, this decrease occurred progressively in younger subjects as head impulse velocity increased, with VOR gain for faster head impulses decreasing significantly in subjects older than 70 years. This finding, in addition to the appearance of RSs, can be explained by the effect of aging on the deterioration of the vestibular system in the semicircular canals.
40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2011 CFR
2011-07-01
... provide output of relative or absolute particulate matter loadings. (5) The bag leak detection system must..., repairs, calibration checks, and zero and span adjustments, emissions data must be obtained by using other...
NASA Technical Reports Server (NTRS)
Garcia-Gorriz, E.; Candela, J.; Font, J.
1998-01-01
The Acoustic Doppler Current Profiler (ADCP) combined with accurate navigation provides absolute current velocities which include information from all the frequencies which have a dynamical presence in the ocean.
ERIC Educational Resources Information Center
Samango-Sprouse, Carole A.; Stapleton, Emily J.; Aliabadi, Farhad; Graw, Robert; Vickers, Rebecca; Haskell, Kathryn; Sadeghin, Teresa; Jameson, Robert; Parmele, Charles L.; Gropman, Andrea L.
2015-01-01
Studies have shown an increased head circumference and the absence of the head tilt reflex as possible risk factors for autism spectrum disorder, allowing for early detection at 12 months in typically developing population of infants. Our aim was to develop a screening tool to identify infants prior to 12 months at risk for autism spectrum…
The Role of Eye and Head Movements in Detecting Information about Fly Balls
ERIC Educational Resources Information Center
Bongers, Raoul M.; Michaels, Claire F.
2008-01-01
The authors attempted to identify perceptual mechanisms that pick up information for initiating a run to catch fly balls and for judging their landing locations. Fly balls have been shown to be tracked with the eyes and head (R. R. D. Oudejans, C. F. Michaels, F. C. Bakker, & K. Davids, 1999). This raised the question of whether constraining eye…
2010-01-01
Background The fungal pathogen Fusarium graminearum causes Fusarium Head Blight (FHB) disease on wheat which can lead to trichothecene mycotoxin (e.g. deoxynivalenol, DON) contamination of grain, harmful to mammalian health. DON is produced at low levels under standard culture conditions when compared to plant infection but specific polyamines (e.g. putrescine and agmatine) and amino acids (e.g. arginine and ornithine) are potent inducers of DON by F. graminearum in axenic culture. Currently, host factors that promote mycotoxin synthesis during FHB are unknown, but plant derived polyamines could contribute to DON induction in infected heads. However, the temporal and spatial accumulation of polyamines and amino acids in relation to that of DON has not been studied. Results Following inoculation of susceptible wheat heads by F. graminearum, DON accumulation was detected at two days after inoculation. The accumulation of putrescine was detected as early as one day following inoculation while arginine and cadaverine were also produced at three and four days post-inoculation. Transcripts of ornithine decarboxylase (ODC) and arginine decarboxylase (ADC), two key biosynthetic enzymes for putrescine biosynthesis, were also strongly induced in heads at two days after inoculation. These results indicated that elicitation of the polyamine biosynthetic pathway is an early response to FHB. Transcripts for genes encoding enzymes acting upstream in the polyamine biosynthetic pathway as well as those of ODC and ADC, and putrescine levels were also induced in the rachis, a flower organ supporting DON production and an important route for pathogen colonisation during FHB. A survey of 24 wheat genotypes with varying responses to FHB showed putrescine induction is a general response to inoculation and no correlation was observed between the accumulation of putrescine and infection or DON accumulation. Conclusions The activation of the polyamine biosynthetic pathway and putrescine in infected heads prior to detectable DON accumulation is consistent with a model where the pathogen exploits the generic host stress response of polyamine synthesis as a cue for production of trichothecene mycotoxins during FHB disease. However, it is likely that this mechanism is complicated by other factors contributing to resistance and susceptibility in diverse wheat genetic backgrounds. PMID:21192794
Nanoimmunoassay to Detect Responses in Head and Neck Cancer: Feasibility in a Mouse Model.
Hubbard, Matthew A; Khalil, Ashraf A; Schoeff, Stephen S; Allak, Amir; VanKoevering, Kyle K; Maxwell, Anne K; Adejumo, Oluwayemisi; Mendez, Rolando E; Jameson, Mark J
2014-07-01
To demonstrate the feasibility of detecting and quantifying extracellular signal-related kinase (ERK) phosphorylation status using nanoimmunoassay (NIA). Analyses using Cal27, SCC25, and OSC19 head and neck squamous carcinoma cell lines in vitro and in a murine xenograft model. NIA and immunoblot were performed on whole-cell lysates, tumor lysates, and fine-needle aspirate biopsies to detect ERK phosphorylation states. Using NIA, all 6 isoforms of ERK1/2, including nonphosphorylated, monophosphorylated, and diphosphorylated species, could be reliably detected, distinguished, and quantified in a single assay using a single antibody. In vitro treatment of Cal27 cells with the epidermal growth factor receptor inhibitor gefitinib abolished phospho-ERK detection by immunoblot but resulted in residual detectable species by NIA. Residual phospho-ERK in gefitinib-treated cells could be further reduced by the addition of the insulin-like growth factor 1 receptor inhibitor OSI-906; this correlated with an additional decrease in proliferation over gefitinib alone. In a pilot study of 4 murine xenograft tumors, NIA performed on tumor lysates and fine-needle aspirate biopsies demonstrated altered ERK profiles after 2 days of gefitinib treatment compared with untreated mice. NIA offers a novel approach to quantitating the activation state of signaling molecules such as ERK in nanoscale in vitro and in vivo samples across a wide dynamic range. As such, it has potential to provide molecular diagnostic information before, during, and after treatment using a minimally invasive technique. Further study is warranted to determine its utility in assessing signaling proteins as biomolecular outcome predictors in clinical trials. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.
Yang, Lin; Dai, Meng; Xu, Canhua; Zhang, Ge; Li, Weichen; Fu, Feng; Shi, Xuetao; Dong, Xiuzhen
2017-01-01
Frequency-difference electrical impedance tomography (fdEIT) reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz). In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects' heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz) significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz) also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection.