Science.gov

Sample records for absolute intensity measurement

  1. Measurement of Disintegration Rates and Absolute {gamma}-ray Intensities

    SciTech Connect

    DeVries, Daniel J.; Griffin, Henry C.

    2006-03-13

    The majority of practical radioactive materials decay by modes that include {gamma}-ray emission. For questions of 'how much' or 'how pure', one must know the absolute intensities of the major radiations. We are using liquid scintillation counting (LSC) to measurements of disintegration rates, coupled with {gamma}-ray spectroscopy to measure absolute {gamma}-ray emission probabilities. Described is a study of the 227Th chain yielding absolute {gamma}-ray intensities with {approx}0.5% accuracy and information on LSC efficiencies.

  2. Ion chambers simplify absolute intensity measurements in the vacuum ultraviolet

    NASA Technical Reports Server (NTRS)

    Sampson, J. A. R.

    1966-01-01

    Single or double ion chamber technique measures absolute radiation intensities in the extreme vacuum ultraviolet region of the spectrum. The ion chambers use rare gases as the ion carrier. Photon absorbed by the gas creates one ion pair so a measure of these is a measure of the number of incident photons.

  3. Absolute intensity measurement of the 4-0 vibration-rotation band of carbon monoxide

    NASA Technical Reports Server (NTRS)

    Chackerian, C., Jr.; Valero, F. P. J.

    1976-01-01

    The absolute intensity of the 4-0 vibration band of CO is measured in spectra obtained using a 25-m base-path multiple-traversal absorption cell and a 5-m scanning spectrometer. The intensities of individual vibration-rotation lines in this band are determined from measurements of their equivalent widths, and absolute values for the rotationless transition moment and the vibration-rotation interaction factor are derived from the measured line strengths. The experimentally obtained vibration-rotation function is compared with a theoretical curve; agreement between theory and experiment is found to be good for the P-branch but poor for the R-branch. It is noted that numerical solutions to the radial Schroedinger equation lead to vibration-rotation function values that are in good agreement with the experiment.

  4. Intensity evaluation using a femtosecond pulse laser for absolute distance measurement.

    PubMed

    Wu, Hanzhong; Zhang, Fumin; Li, Jianshuang; Cao, Shiying; Meng, Xiangsong; Qu, Xinghua

    2015-06-10

    In this paper, we propose a method of intensity evaluation based on different pulse models using a femtosecond pulse laser, which enables long-range absolute distance measurement with nanometer precision and large non-ambiguity range. The pulse cross-correlation is analyzed based on different pulse models, including Gaussian, Sech(2), and Lorenz. The DC intensity and the amplitude of the cross-correlation patterns are also demonstrated theoretically. In the experiments, we develop a new combined system and perform the distance measurements on an underground granite rail system. The DC intensity and amplitude of the interference fringes are measured and show a good agreement with the theory, and the distance to be determined can be up to 25 m using intensity evaluation, within 64 nm deviation compared with a He-Ne incremental interferometer, and corresponds to a relative precision of 2.7×10(-9). PMID:26192864

  5. Intensity evaluation using a femtosecond pulse laser for absolute distance measurement.

    PubMed

    Wu, Hanzhong; Zhang, Fumin; Li, Jianshuang; Cao, Shiying; Meng, Xiangsong; Qu, Xinghua

    2015-06-10

    In this paper, we propose a method of intensity evaluation based on different pulse models using a femtosecond pulse laser, which enables long-range absolute distance measurement with nanometer precision and large non-ambiguity range. The pulse cross-correlation is analyzed based on different pulse models, including Gaussian, Sech(2), and Lorenz. The DC intensity and the amplitude of the cross-correlation patterns are also demonstrated theoretically. In the experiments, we develop a new combined system and perform the distance measurements on an underground granite rail system. The DC intensity and amplitude of the interference fringes are measured and show a good agreement with the theory, and the distance to be determined can be up to 25 m using intensity evaluation, within 64 nm deviation compared with a He-Ne incremental interferometer, and corresponds to a relative precision of 2.7×10(-9).

  6. Measurements of absolute line intensities in carbon dioxide bands near 5.2 microns

    NASA Technical Reports Server (NTRS)

    Rinsland, C. P.; Benner, D. C.; Devi, V. M.

    1985-01-01

    A nonlinear least-squares spectral fitting procedure has been used to derive experimental absolute intensities for over 300 unblended lines belonging to twelve CO2 bands in the 5.2-micron region. The spectral data were recorded at 0.01/cm resolution and room temperature with the Fourier transform spectrometer in the McMath solar telescope complex at the National Solar Observatory on Kitt Peak and have a signal-to-rms noise ratio of 2000-4000. A natural sample of carbon dioxide was used as the sample gas. For each band, the measured line intensities have been analyzed to derive the vibrational band intensity and coefficients of the F factor. The results are compared to the values used to calculate the intensities in the 1982 Air Force Geophysics Laboratory line parameters compilation.

  7. Absolute intensity measurements of CO2 bands in the 2395-2680/cm region

    NASA Technical Reports Server (NTRS)

    Malathy Devi, V.; Benner, D. C.; Rinsland, C. P.

    1984-01-01

    Absolute intensities for over 800 transitions belonging to twelve bands of (C-12)(O-16)2, (O-16)(C-12)(O-18), (O-16)(C-12)(O-17), and (O-16)(C-13)(O-18) molecules in the 2395-2680/cm spectral region have been derived using a nonlinear least-squares spectral fitting procedure. The data used in the analysis were recorded at room temperature and low pressure with the 0.01/cm resolution Fourier transform spectrometer in the McMath solar telescope complex at the National Solar Observatory. The measured intensities obtained for each band have been analyzed to derive the vibrational band intensity and F-factor coefficients. The results are compared with other published values.

  8. Spectroscopic determination of electrical conductivity in an MHD duct from absolute intensity measurements

    NASA Technical Reports Server (NTRS)

    Wang, S. Y.; Smith, M.

    1977-01-01

    Measurements of the electrical conductivity in the NASA Lewis cesium seeded, H2-O2 MHD duct have been previously reported. In order to corroborate the above measurements and to analyze the possibility of nonuniform seed injection as a cause of the deviations, a spectroscopic investigation of the plasma conductivity has been undertaken. Transverse profiles of the absolute integrated intensity were measured from the optically thin lines of CSI-.5664 microns and .5636 microns. Radial profiles of emission coefficient were obtained from the measured transverse profiles of intensity by Abel inversion. Radial profiles of electrical conductivity were then obtained under two different assumptions. In the first, the Cs seed fraction is assumed uniform and equal to the measured flow rate at the time when the temperature and conductivity were obtained. In the second method, the local temperature and pressure are taken to be those given by a one-dimensional channel calculation including heat transfer and friction. In this case profiles of conductivity and seed fractions are obtained. The results of the two methods are compared to the previously measured conductivity.

  9. Spectroscopic determination of electrical conductivity in an MHD duct from absolute intensity measurements

    NASA Technical Reports Server (NTRS)

    Wang, S. Y.; Smith, J. M.

    1977-01-01

    Measurements of the electrical conductivity in the NASA Lewis cesium seeded, H2-O2 MHD duct made by applying a voltage across the channel from one end electrode to the other, measuring the current, and using the inner electrodes as probes to monitor the voltage distribution along the channel were found to be in good agreement with theory except at low combustion pressures and/or high ratios of seed/oxygen mass flows. To corroborate these measurements and to analyze the possibility of nonuniform seed injection as a cause of the above deviations, a spectroscopic investigation of the plasma conductivity was undertaken. Radial profiles of emission coefficient were obtained from measured transverse profiles of the absolute integrated intensity by Abel inversion. Radial profiles of electrical conductivity were then obtained under two different assumptions. In the first the Cs seed fraction is assumed uniform and equal to the measured flow rate at the time when the temperature and conductivity were obtained. In the second method the local temperature and pressure are taken to be those given by a one-dimensional channel calculation including heat transfer and friction. The results of the two methods are compared to the previously measured conductivity.

  10. Absolute intensity measurements of the CO2 bands 401-III /backward arrow/ 000 and 411-III /backward arrow/ 010

    NASA Technical Reports Server (NTRS)

    Valero, F. P. J.

    1977-01-01

    The absolute intensities of the studied transitions of CO2 have been measured from spectra obtained under high resolution. Vibration-rotation line intensities and integrated band intensities are reported. The studied bands are characterized by origins at 7593.5 and 7584 cm to the minus 1. Spectra were obtained by an Ames' 25-m base path White-type absorption cell equipped with silver-coated mirrors together with a 5-m focal length Czerny-Turner scanning spectrometer. The procedures for calculating the widths and intensities are explained, and uncertainty limits of the reported values are considered.

  11. Absolute neutrino mass measurements

    SciTech Connect

    Wolf, Joachim

    2011-10-06

    The neutrino mass plays an important role in particle physics, astrophysics and cosmology. In recent years the detection of neutrino flavour oscillations proved that neutrinos carry mass. However, oscillation experiments are only sensitive to the mass-squared difference of the mass eigenvalues. In contrast to cosmological observations and neutrino-less double beta decay (0v2{beta}) searches, single {beta}-decay experiments provide a direct, model-independent way to determine the absolute neutrino mass by measuring the energy spectrum of decay electrons at the endpoint region with high accuracy.Currently the best kinematic upper limits on the neutrino mass of 2.2eV have been set by two experiments in Mainz and Troitsk, using tritium as beta emitter. The next generation tritium {beta}-experiment KATRIN is currently under construction in Karlsruhe/Germany by an international collaboration. KATRIN intends to improve the sensitivity by one order of magnitude to 0.2eV. The investigation of a second isotope ({sup 137}Rh) is being pursued by the international MARE collaboration using micro-calorimeters to measure the beta spectrum. The technology needed to reach 0.2eV sensitivity is still in the R and D phase. This paper reviews the present status of neutrino-mass measurements with cosmological data, 0v2{beta} decay and single {beta}-decay.

  12. STS-9 Shuttle grow - Ram angle effect and absolute intensities

    NASA Technical Reports Server (NTRS)

    Swenson, G. R.; Mende, S. B.; Clifton, K. S.

    1986-01-01

    Visible imagery from Space Shuttle mission STS-9 (Spacelab 1) has been analyzed for the ram angle effect and the absolute intensity of glow. The data are compared with earlier measurements and the anomalous high intensities at large ram angles are confirmed. Absolute intensities of the ram glow on the shuttle tile, at 6563 A, are observed to be about 20 times more intense than those measured on the AE-E spacecraft. Implications of these observations for an existing theory of glow involving NO2 are presented.

  13. Absolute intensity of radiation emitted by uranium plasmas

    NASA Technical Reports Server (NTRS)

    Jalufka, N. W.; Lee, J. H.; Mcfarland, D. R.

    1975-01-01

    The absolute intensity of radiation emitted by fissioning and nonfissioning uranium plasmas in the spectral range from 350 nm to 1000 nm was measured. The plasma was produced in a plasma-focus apparatus and the plasma properties are simular to those anticipated for plasma-core nuclear reactors. The results are expected to contribute to the establishment of design criteria for the development of plasma-core reactors.

  14. Absolute intensity measurements of the optical second-harmonic response of metals from 0.9 to 2.5 eV

    NASA Astrophysics Data System (ADS)

    Matranga, Christopher; Guyot-Sionnest, Philippe

    2001-11-01

    The absolute intensity of the optical second-harmonic response and its spectral (ωfund≈0.9-2.5 eV) dependence has been measured for Ag(111), polycrystalline Ag, 4-Aminothiophenol/Ag (4-ATP/Ag) and decanethiol/Ag (DT/Ag) surfaces in contact with a liquid electrolyte. Preliminary spectra are also reported for polycrystalline Au and Cu(111) samples. For second-harmonic energies below the plasmon resonance, the magnitude of the nonlinear optical response of clean Ag samples increases as electrode potentials are made more positive. This trend reverses itself for energies above the plasmon resonance. The adsorbate-covered surfaces show a weak or nonexistent potential dependence. A unique feature is found in the 4-ATP/Ag spectra which could possibly be due to a surface charge-transfer state. The Ag results are discussed in the context of a free-electron response from which the spectral and potential dependence of the complex microscopic parameter, a(ω), are extracted. The features in the Au and Cu(111) spectra are not adequately described by this free-electron model and must be related to the effects of interband transitions on the nonlinear optical response.

  15. Apparatus for absolute pressure measurement

    NASA Technical Reports Server (NTRS)

    Hecht, R. (Inventor)

    1969-01-01

    An absolute pressure sensor (e.g., the diaphragm of a capacitance manometer) was subjected to a superimposed potential to effectively reduce the mechanical stiffness of the sensor. This substantially increases the sensitivity of the sensor and is particularly useful in vacuum gauges. An oscillating component of the superimposed potential induced vibrations of the sensor. The phase of these vibrations with respect to that of the oscillating component was monitored, and served to initiate an automatic adjustment of the static component of the superimposed potential, so as to bring the sensor into resonance at the frequency of the oscillating component. This establishes a selected sensitivity for the sensor, since a definite relationship exists between resonant frequency and sensitivity.

  16. Absolute intensities and self-, N2-, and air-broadened Lorentz halfwidths for selected lines in the nu3 band of (C-12)H3D from measurements with a tunable diode laser spectrometer

    NASA Technical Reports Server (NTRS)

    Malathy Devi, V.; Benner, D. C.; Rinsland, C. P.; Smith, M. A. H.; Thakur, K. B.

    1986-01-01

    Absolute intensities and self-, air- and N2-broadened half-widths have been determined for the first time for individual lines in the nu3(A1) band of (C-12)H3D near 7.6 microns from measurements of individual vibration-rotation lines using a tunable diode laser spectrometer. The intensity measurements are believed to be accurate to within three percent. Within experimental uncertainties, equal broadening efficiencies are found for both air and nitrogen. Self-broadened half-widths determined for three transitions yield an average half-width value of 0.803 + or -0.0010/cm/atm at 296 K.

  17. Method to obtain absolute impurity density profiles combining charge exchange and beam emission spectroscopy without absolute intensity calibrationa)

    NASA Astrophysics Data System (ADS)

    Kappatou, A.; Jaspers, R. J. E.; Delabie, E.; Marchuk, O.; Biel, W.; Jakobs, M. A.

    2012-10-01

    Investigation of impurity transport properties in tokamak plasmas is essential and a diagnostic that can provide information on the impurity content is required. Combining charge exchange recombination spectroscopy (CXRS) and beam emission spectroscopy (BES), absolute radial profiles of impurity densities can be obtained from the CXRS and BES intensities, electron density and CXRS and BES emission rates, without requiring any absolute calibration of the spectra. The technique is demonstrated here with absolute impurity density radial profiles obtained in TEXTOR plasmas, using a high efficiency charge exchange spectrometer with high etendue, that measures the CXRS and BES spectra along the same lines-of-sight, offering an additional advantage for the determination of absolute impurity densities.

  18. Absolute calibration in vivo measurement systems

    SciTech Connect

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs.

  19. An absolute measure for a key currency

    NASA Astrophysics Data System (ADS)

    Oya, Shunsuke; Aihara, Kazuyuki; Hirata, Yoshito

    It is generally considered that the US dollar and the euro are the key currencies in the world and in Europe, respectively. However, there is no absolute general measure for a key currency. Here, we investigate the 24-hour periodicity of foreign exchange markets using a recurrence plot, and define an absolute measure for a key currency based on the strength of the periodicity. Moreover, we analyze the time evolution of this measure. The results show that the credibility of the US dollar has not decreased significantly since the Lehman shock, when the Lehman Brothers bankrupted and influenced the economic markets, and has increased even relatively better than that of the euro and that of the Japanese yen.

  20. Use of intensity quotients and differences in absolute structure refinement.

    PubMed

    Parsons, Simon; Flack, Howard D; Wagner, Trixie

    2013-06-01

    Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement. PMID:23719469

  1. Measurement of absolute gravity acceleration in Firenze

    NASA Astrophysics Data System (ADS)

    de Angelis, M.; Greco, F.; Pistorio, A.; Poli, N.; Prevedelli, M.; Saccorotti, G.; Sorrentino, F.; Tino, G. M.

    2011-01-01

    This paper reports the results from the accurate measurement of the acceleration of gravity g taken at two separate premises in the Polo Scientifico of the University of Firenze (Italy). In these laboratories, two separate experiments aiming at measuring the Newtonian constant and testing the Newtonian law at short distances are in progress. Both experiments require an independent knowledge on the local value of g. The only available datum, pertaining to the italian zero-order gravity network, was taken more than 20 years ago at a distance of more than 60 km from the study site. Gravity measurements were conducted using an FG5 absolute gravimeter, and accompanied by seismic recordings for evaluating the noise condition at the site. The absolute accelerations of gravity at the two laboratories are (980 492 160.6 ± 4.0) μGal and (980 492 048.3 ± 3.0) μGal for the European Laboratory for Non-Linear Spectroscopy (LENS) and Dipartimento di Fisica e Astronomia, respectively. Other than for the two referenced experiments, the data here presented will serve as a benchmark for any future study requiring an accurate knowledge of the absolute value of the acceleration of gravity in the study region.

  2. A Methodology for Absolute Isotope Composition Measurement

    NASA Astrophysics Data System (ADS)

    Shen, J. J.; Lee, D.; Liang, W.

    2007-12-01

    Double spike technique was a well defined method for isotope composition measurement by TIMS of samples which have natural mass fractionation effect, but it is still a problem to define the isotope composition for double spike itself. In this study, we modified the old double spike technique and found that we could use the modified technique to solve the ¡§true¡¨ isotope composition of double spike itself. According the true isotope composition of double spike, we can measure the absolute isotope composition if the sample has natural fractionation effect. A new vector analytical method has been developed in order to obtain the true isotopic composition of a 42Ca-48Ca double spike, and this is achieved by using two different sample-spike mixtures combined with the double spike and the natural Ca data. Because the natural sample, the two mixtures, and the spike should all lie on a single mixing line, we are able to constrain the true isotopic composition of our double spike using this new approach. This method not only can be used in Ca system but also in Ti, Cr, Fe, Ni, Zn, Mo, Ba and Pb systems. The absolute double spike isotopic ratio is important, which can save a lot of time to check different reference standards. Especially for Pb, radiogenic isotope system, the decay systems embodied in three of four naturally occurring isotopes induce difficult to obtain true isotopic ratios for absolute dating.

  3. Absolute method of measuring magnetic susceptibility

    USGS Publications Warehouse

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  4. Absolute Measurement of Electron Cloud Density

    SciTech Connect

    Covo, M K; Molvik, A W; Cohen, R H; Friedman, A; Seidl, P A; Logan, G; Bieniosek, F; Baca, D; Vay, J; Orlando, E; Vujic, J L

    2007-06-21

    Beam interaction with background gas and walls produces ubiquitous clouds of stray electrons that frequently limit the performance of particle accelerator and storage rings. Counterintuitively we obtained the electron cloud accumulation by measuring the expelled ions that are originated from the beam-background gas interaction, rather than by measuring electrons that reach the walls. The kinetic ion energy measured with a retarding field analyzer (RFA) maps the depressed beam space-charge potential and provides the dynamic electron cloud density. Clearing electrode current measurements give the static electron cloud background that complements and corroborates with the RFA measurements, providing an absolute measurement of electron cloud density during a 5 {micro}s duration beam pulse in a drift region of the magnetic transport section of the High-Current Experiment (HCX) at LBNL.

  5. Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

    SciTech Connect

    Sannibale, F.; Stupakov, G.V.; Zolotorev, M.S.; Filippetto, D.; Jagerhofer, L.; /Vienna, Tech. U.

    2009-12-09

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  6. Absolute bunch length measurements by incoherent radiation fluctuation analysis

    SciTech Connect

    Sannibale, Fernando; Stupakov, Gennady; Zolotorev, Max; Filippetto, Daniele; Jagerhofer, Lukas

    2008-09-29

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  7. Are ceramics and bricks reliable absolute geomagnetic intensity carriers?

    NASA Astrophysics Data System (ADS)

    Morales, Juan; Goguitchaichvili, Avto; Aguilar-Reyes, Bertha; Pineda-Duran, Modesto; Camps, Pierre; Carvallo, Claire; Calvo-Rathert, Manuel

    2011-08-01

    A detailed rock-magnetic and archeointensity study was carried out on materials baked by a western Mexican artisan following traditional techniques to produce faithful reproductions of archeological pieces of the Michoacán region (Western Mesoamerica). The field strength at the site (41.0 ± 0.5 μT) was measured with a fluxgate magnetometer and the temperature of the furnace during the baking process was monitored continually by means of a thermocouple placed in the middle of the baking cavity. Rock-magnetic experiments performed on the raw material (clay and paste) and on insitu prepared baked ceramics and bricks included measurement of thermomagnetic curves (susceptibility and strong-field magnetization versus temperature), first-order reversal curves (FORC), anisotropy of magnetic susceptibility (AMS) and anisotropy of thermoremanent magnetization (A-TRM). Magnetite and probably hematite are present in the samples as carriers of the remanence. Hysteresis ratios suggest that the samples fall in the pseudo-single-domain grain size region, which may indicate a mixture of multi-domain and a significant amount of single-domain grains. Ceramic pieces and brick fragments were subjected to the Thellier-Coe archeointensity method and to an alternative paleointensity experiment, with a TRIAXE magnetometer, in order to check whether they are faithful recorders of the local geomagnetic field strength. Mean raw-intensity of sample M1 (pottery) overestimates a 7% the expected site intensity, while those corresponding to the brick samples (LQ1 and LQ2) underestimate it 15%. Brick sample LNQ shows a slightly lower intensity (7%), but agrees with the expected site intensity within the experimental uncertainty. The intensity retrieved from the volcanic fragment also included closely reproduces the expected intensity. After A-TRM and cooling-rate corrections, all mean raw values move closer to the expected intensity. Measurement of temperatures at different parts inside the kiln

  8. Glassy carbon as an absolute intensity calibration standard for small-angle scattering.

    SciTech Connect

    Zhang, F.; Ilavsky, J.; Long, G.; Allen, A.; Quintana, J.; Jemian, P.; NIST

    2010-05-01

    Absolute calibration of small-angle scattering (SAS) intensity data (measured in terms of the differential scattering cross section per unit sample volume per unit solid angle) is essential for many important aspects of quantitative SAS analysis, such as obtaining the number density, volume fraction, and specific surface area of the scatterers. It also enables scattering data from different instruments (light, X-ray, or neutron scattering) to be combined, and it can even be useful to detect the existence of artifacts in the experimental data. Different primary or secondary calibration methods are available. In the latter case, absolute intensity calibration requires a stable artifact with the necessary scattering profile. Glassy carbon has sometimes been selected as this intensity calibration standard. Here we review the spatial homogeneity and temporal stability of one type of commercially available glassy carbon that is being used as an intensity calibration standard at a number of SAS facilities. We demonstrate that glassy carbon is sufficiently homogeneous and stable during routine use to be relied upon as a suitable standard for absolute intensity calibration of SAS data.

  9. Measurement of Absolute Carbon Isotope Ratios: Mechanisms and Implications

    NASA Astrophysics Data System (ADS)

    Vogel, J. S.; Giacomo, J. A.; Dueker, S. R.

    2012-12-01

    An accelerator mass spectrometer (AMS) produced absolute isotope ratio measurements for 14C/13C as tested against >500 samples of NIST SRM-4990-C (OxII 14C standard) to an accuracy of 2.2±0.6‰ over a period of one year with measurements made to 1% counting statistics. The spectrometer is not maximized for 13C/12C, but measured ∂13C to 0.4±0.1‰ accuracy, with known methods for improvement. An AMS produces elemental anions from a sputter ion source and includes a charge-changing collision in a gas cell to isolate the rare 14C from the common isotopes and molecular isobars. Both these physical processes have been modeled to determine the parameters providing such absolute measures. Neutral resonant ionization in a cesium plasma produces mass-independent ionization, while velocity dependent charge-state distributions in gas collisions produce relative ion beam intensities that are linear in mass at specific collision energies. The mechanisms are not specific to carbon isotopes, but stand alone absolute IRMS (AIR-MS) instruments have not yet been made. Aside from the obvious applications in metrology, AIR-MS is particularly valuable in coupled separatory MS because no internal or external standards are required. Sample definition processes can be compared, even if no exact standard reference sample exists. Isotope dilution measurements do not require standards matching the dilution end-points and can be made over an extended, even extrapolated, range.

  10. High angular resolution absolute intensity of the solar continuum from 1400 to 1790 A.

    NASA Technical Reports Server (NTRS)

    Brueckner, G. E.; Moe, O. K.

    1972-01-01

    Absolute intensities of the solar UV continuum from 1400 to 1790 A have been measured from rocket spectra taken on August 13, 1970. The spectra had an angular resolution of 2 arc sec by 1 arc min, and the pointing accuracy of the instrument was plus or minus 2 arc sec. This permits us to study the center-to-limb variation of the intensity with a spatial resolution of 2 arc sec. Four positions on the solar disk have been studied corresponding to values of cos theta = 0.12, 0.22, 0.28 and 0.72, where theta is the heliocentric position angle. The measurements give higher values for the intensity than recent photoelectric measurement, but are in good agreement with the intensities of Widing et al.

  11. Absolute flux measurements for swift atoms

    NASA Technical Reports Server (NTRS)

    Fink, M.; Kohl, D. A.; Keto, J. W.; Antoniewicz, P.

    1987-01-01

    While a torsion balance in vacuum can easily measure the momentum transfer from a gas beam impinging on a surface attached to the balance, this measurement depends on the accommodation coefficients of the atoms with the surface and the distribution of the recoil. A torsion balance is described for making absolute flux measurements independent of recoil effects. The torsion balance is a conventional taut suspension wire design and the Young modulus of the wire determines the relationship between the displacement and the applied torque. A compensating magnetic field is applied to maintain zero displacement and provide critical damping. The unique feature is to couple the impinging gas beam to the torsion balance via a Wood's horn, i.e., a thin wall tube with a gradual 90 deg bend. Just as light is trapped in a Wood's horn by specular reflection from the curved surfaces, the gas beam diffuses through the tube. Instead of trapping the beam, the end of the tube is open so that the atoms exit the tube at 90 deg to their original direction. Therefore, all of the forward momentum of the gas beam is transferred to the torsion balance independent of the angle of reflection from the surfaces inside the tube.

  12. Absolute intensity calibration of the 32-channel heterodyne radiometer on experimental advanced superconducting tokamak

    SciTech Connect

    Liu, X.; Zhao, H. L.; Liu, Y. Li, E. Z.; Han, X.; Ti, A.; Hu, L. Q.; Zhang, X. D.; Domier, C. W.; Luhmann, N. C.

    2014-09-15

    This paper presents the results of the in situ absolute intensity calibration for the 32-channel heterodyne radiometer on the experimental advanced superconducting tokamak. The hot/cold load method is adopted, and the coherent averaging technique is employed to improve the signal to noise ratio. Measured spectra and electron temperature profiles are compared with those from an independent calibrated Michelson interferometer, and there is a relatively good agreement between the results from the two different systems.

  13. Absolute intensity and polarization of rotational Raman scattering from N2, O2, and CO2

    NASA Technical Reports Server (NTRS)

    Penney, C. M.; St.peters, R. L.; Lapp, M.

    1973-01-01

    An experimental examination of the absolute intensity, polarization, and relative line intensities of rotational Raman scattering (RRS) from N2, O2, and CO2 is reported. The absolute scattering intensity for N2 is characterized by its differential cross section for backscattering of incident light at 647.1 nm, which is calculated from basic measured values. The ratio of the corresponding cross section for O2 to that for N2 is 2.50 plus or minus 5 percent. The intensity recent for N2, O2, and CO2 are shown to compare favorably to values calculated from recent measurements of the depolarization of Rayleigh scattering plus RRS. Measured depolarizations of various RRS lines agree to within a few percent with the theoretical value of 3/4. Detailed error analyses are presented for intensity and depolarization measurements. Finally, extensive RRS spectra at nominal gas temperatures of 23 C, 75 C, and 125 C are presented and shown to compare favorably to theoretical predictions.

  14. Biochip Image Grid Normalization Absolute Signal Fluorescence Measurement Using

    SciTech Connect

    Alferov, Oleg

    2001-04-17

    This software was developed to measure absolute fluorescent intensities of gel pads on a microchip in units defined by a standard fluorescent slide. It can accomodate varying measurement conditions (e.g. exposure time, sensitivity of detector, resolution of detector, etc.) as well as fluorescent microscopes with non-uniform sensitivity across their field of view allowing the user to compare measurements done on different detectors with varying exposure times, sensitivities, and resolutions. The software is designed both to operate Roper Scientific, Inc. cameras and to use image files produced by the program supplied with that equipment for its calculations. the intensity of the gel pad signal is computed so as to reduce background influence.

  15. Biochip Image Grid Normalization Absolute Signal Fluorescence Measurement Using

    2001-04-17

    This software was developed to measure absolute fluorescent intensities of gel pads on a microchip in units defined by a standard fluorescent slide. It can accomodate varying measurement conditions (e.g. exposure time, sensitivity of detector, resolution of detector, etc.) as well as fluorescent microscopes with non-uniform sensitivity across their field of view allowing the user to compare measurements done on different detectors with varying exposure times, sensitivities, and resolutions. The software is designed both tomore » operate Roper Scientific, Inc. cameras and to use image files produced by the program supplied with that equipment for its calculations. the intensity of the gel pad signal is computed so as to reduce background influence.« less

  16. Infrared mapping of ultrasound fields generated by medical transducers: Feasibility of determining absolute intensity levels

    PubMed Central

    Khokhlova, Vera A.; Shmeleva, Svetlana M.; Gavrilov, Leonid R.; Martin, Eleanor; Sadhoo, Neelaksh; Shaw, Adam

    2013-01-01

    Considerable progress has been achieved in the use of infrared (IR) techniques for qualitative mapping of acoustic fields of high intensity focused ultrasound (HIFU) transducers. The authors have previously developed and demonstrated a method based on IR camera measurement of the temperature rise induced in an absorber less than 2 mm thick by ultrasonic bursts of less than 1 s duration. The goal of this paper was to make the method more quantitative and estimate the absolute intensity distributions by determining an overall calibration factor for the absorber and camera system. The implemented approach involved correlating the temperature rise measured in an absorber using an IR camera with the pressure distribution measured in water using a hydrophone. The measurements were conducted for two HIFU transducers and a flat physiotherapy transducer of 1 MHz frequency. Corresponding correction factors between the free field intensity and temperature were obtained and allowed the conversion of temperature images to intensity distributions. The system described here was able to map in good detail focused and unfocused ultrasound fields with sub-millimeter structure and with local time average intensity from below 0.1 W/cm2 to at least 50 W/cm2. Significantly higher intensities could be measured simply by reducing the duty cycle. PMID:23927199

  17. Intensity Biased PSP Measurement

    NASA Technical Reports Server (NTRS)

    Subramanian, Chelakara S.; Amer, Tahani R.; Oglesby, Donald M.; Burkett, Cecil G., Jr.

    2000-01-01

    The current pressure sensitive paint (PSP) technique assumes a linear relationship (Stern-Volmer Equation) between intensity ratio (I(sub o)/I) and pressure ratio (P/P(sub o)) over a wide range of pressures (vacuum to ambient or higher). Although this may be valid for some PSPs, in most PSPs the relationship is nonlinear, particularly at low pressures (less than 0.2 psia when the oxygen level is low). This non-linearity can be attributed to variations in the oxygen quenching (de-activation) rates (which otherwise is assumed constant) at these pressures. Other studies suggest that some paints also have non-linear calibrations at high pressures; because of heterogeneous (non-uniform) oxygen diffusion and quenching. Moreover, pressure sensitive paints require correction for the output intensity due to light intensity variation, paint coating variation, model dynamics, wind-off reference pressure variation, and temperature sensitivity. Therefore to minimize the measurement uncertainties due to these causes, an insitu intensity correction method was developed. A non-oxygen quenched paint (which provides a constant intensity at all pressures, called non-pressure sensitive paint, NPSP) was used for the reference intensity (I(sub NPSP) with respect to which all the PSP intensities (I) were measured. The results of this study show that in order to fully reap the benefits of this technique, a totally oxygen impermeable NPSP must be available.

  18. Intensity Biased PSP Measurement

    NASA Technical Reports Server (NTRS)

    Subramanian, Chelakara S.; Amer, Tahani R.; Oglesby, Donald M.; Burkett, Cecil G., Jr.

    2000-01-01

    The current pressure sensitive paint (PSP) technique assumes a linear relationship (Stern-Volmer Equation) between intensity ratio (I(sub 0)/I) and pressure ratio (P/P(sub 0)) over a wide range of pressures (vacuum to ambient or higher). Although this may be valid for some PSPs, in most PSPs the relationship is nonlinear, particularly at low pressures (less than 0.2 psia when the oxygen level is low). This non-linearity can be attributed to variations in the oxygen quenching (de-activation) rates (which otherwise is assumed constant) at these pressures. Other studies suggest that some paints also have non-linear calibrations at high pressures; because of heterogeneous (non-uniform) oxygen diffusion and c quenching. Moreover, pressure sensitive paints require correction for the output intensity due to light intensity variation, paint coating variation, model dynamics, wind-off reference pressure variation, and temperature sensitivity. Therefore to minimize the measurement uncertainties due to these causes, an in- situ intensity correction method was developed. A non-oxygen quenched paint (which provides a constant intensity at all pressures, called non-pressure sensitive paint, NPSP) was used for the reference intensity (I(sub NPSP)) with respect to which all the PSP intensities (I) were measured. The results of this study show that in order to fully reap the benefits of this technique, a totally oxygen impermeable NPSP must be available.

  19. MEASUREMENTS OF ABSOLUTE ABUNDANCES IN SOLAR FLARES

    SciTech Connect

    Warren, Harry P.

    2014-05-01

    We present measurements of elemental abundances in solar flares with the EUV Variability Experiment (EVE) on the Solar Dynamics Observatory. EVE observes both high temperature Fe emission lines (Fe XV-Fe XXIV) and continuum emission from thermal bremsstrahlung that is proportional to the abundance of H. By comparing the relative intensities of line and continuum emission it is possible to determine the enrichment of the flare plasma relative to the composition of the photosphere. This is the first ionization potential or FIP bias (f). Since thermal bremsstrahlung at EUV wavelengths is relatively insensitive to the electron temperature, it is important to account for the distribution of electron temperatures in the emitting plasma. We accomplish this by using the observed spectra to infer the differential emission measure distribution and FIP bias simultaneously. In each of the 21 flares that we analyze we find that the observed composition is close to photospheric. The mean FIP bias in our sample is f = 1.17 ± 0.22. This analysis suggests that the bulk of the plasma evaporated during a flare comes from deep in the chromosphere, below the region where elemental fractionation occurs.

  20. Low cost varying synthetic wavelength technique for absolute distance measurement

    NASA Astrophysics Data System (ADS)

    Le Floch, S.; Salvadé, Y.

    2010-04-01

    A new low-cost superheterodyne configuration, without acousto-optic modulator, is applied to the two-wavelength interferometry for absolute distance measurement. The principle relies on a synchronized frequency sweep of two optical signals, but with different frequency excursions. The frequency difference between the two optical waves is highly accurate. This is realized by injecting a frequency modulated laser signal in an intensity modulator that is biased at halfwave voltage and driven by a digitally swept radio-frequency signal between 13 and 15 GHz. This latter is a continuous up and down ramp. The two synchronized optical signals emerging from the modulator produce in a Michelson interferometer a distance dependent superheterodyne signal, with a variable synthetic wavelength of about 10 mm. The superheterodyne frequency depends linearly on distance and on the radio-frequency excursion. The integration time for a distance measurement point corresponds to the duration of single sweep (i.e. one millisecond in our case). Absolute distance measurements from 1 to 15 meters yield an accuracy of +/-50 μm, showing the validity of the technique.

  1. Absolute measurements of fast neutrons using yttrium

    SciTech Connect

    Roshan, M. V.; Springham, S. V.; Rawat, R. S.; Lee, P.; Krishnan, M.

    2010-08-15

    Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f{sub n}{approx}4.1x10{sup -4} with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10{sup 8} neutrons per discharge.

  2. Measurement of Itch Intensity.

    PubMed

    Reich, Adam; Szepietowski, Jacek C

    2016-01-01

    Measurement of itch intensity is essential to properly evaluate pruritic disease severity, to understand the patients' needs and burden, and especially to assess treatment efficacy, particularly in clinical trials. However, measurement of itch remains a challenge, as, per definition, it is a subjective sensation and assessment of this symptom represents significant difficulty. Intensity of itch must be considered in relation to its duration, localization, course of symptoms, presence and type of scratch lesions, response to antipruritic treatment, and quality of life impairment. Importantly, perception of itch may also be confounded by different cofactors including but not limited to patient general condition and other coexisting ailments. In the current chapter we characterize the major methods of itch assessments that are used in daily clinical life and as research tools. Different methods of itch assessment have been developed; however, so far none is without limitations and any data on itch intensity should always be interpreted with caution. Despite these limitations, it is strongly recommended to implement itch measurement tools in routine daily practice, as it would help in proper assessment of patient clinical status. In order to improve evaluation of itch in research studies, it is recommended to use at least two independent methods, as such an approach should increase the validity of achieved results. PMID:27578068

  3. Absolute line intensities in CO2 bands near 4.8 microns

    NASA Technical Reports Server (NTRS)

    Rinsland, C. P.; Benner, D. C.; Devi, V. M.

    1986-01-01

    Absolute intensities for 726 unblended lines in 20 bands of C-12(O-16)2, C-13(O-16)2, O-16C-12O-18, and O-16C-12O-17 in the 4.8-micron spectral region have been determined using a natural sample of ultrahigh-purity CO2. Spectral data were recorded at low pressure (less than 10 torr) and room temperature with the Fourier transform spectrometer in the McMath solar telescope complex on Kitt Peak. Derived vibrational band intensities and coefficients of the F factor for each band were compared to values of the 1982 Air Force Geophysics Laboratory line parameters compilation. The present work fills out the CO2 lines in the 5-micron band systems. Lines in the strongest of these measured bands are being used to infer atmospheric pressure from high-resolution stratospheric spectra recorded during the Spacelab 3 Atmospheric Trace Molecule Spectroscopy experiment.

  4. An All Fiber White Light Interferometric Absolute Temperature Measurement System

    PubMed Central

    Kim, Jeonggon Harrison

    2008-01-01

    Recently the author of this article proposed a new signal processing algorithm for an all fiber white light interferometer. In this article, an all fiber white light interferometric absolute temperature measurement system is presented using the previously proposed signal processing algorithm. Stability and absolute temperature measurement were demonstrated. These two tests demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe and 0.0005 fringe, respectively. A hysteresis test from 373K to 873K was also presented. Finally, robustness of the sensor system towards laser diode temperature drift, AFMZI temperature drift and PZT non-linearity was demonstrated.

  5. Absolute continuum intensity diagnostics of a novel large coaxial gridded hollow cathode argon plasma

    NASA Astrophysics Data System (ADS)

    Gao, Ruilin; Yuan, Chengxun; Li, Hui; Jia, Jieshu; Zhou, Zhong-Xiang; Wu, Jian; Wang, Ying; Wang, Xiaoou

    2016-08-01

    This paper reports a novel coaxial gridded hollow discharge during operation at low pressure (20 Pa-80 Pa) in an argon atmosphere. A homogeneous hollow discharge was observed under different conditions, and the excitation mechanism and the discharge parameters for the hollow cathode plasma were examined at length. An optical emission spectrometry (OES) method, with a special focus on absolute continuum intensity method, was employed to measure the plasma parameters. The Langmuir probe measurement (LPM) was used to verify the OES results. Both provided electron density values (ne) in the order of 1016 m-3 for different plasma settings. Taken together, the results show that the OES method is an effective approach to diagnosing the similar plasma, especially when the LPM is hardly operated.

  6. Method and apparatus for making absolute range measurements

    DOEpatents

    Allison, S.W.; Cates, M.R.; Key, W.S.; Sanders, A.J.; Earl, D.D.

    1999-06-22

    This invention relates to a method and apparatus for making absolute distance or ranging measurements using Fresnel diffraction. The invention employs a source of electromagnetic radiation having a known wavelength or wavelength distribution, which sends a beam of electromagnetic radiation through an object which causes it to be split (hereinafter referred to as a beam splitter''), and then to a target. The beam is reflected from the target onto a screen containing an aperture spaced a known distance from the beam splitter. The aperture is sized so as to produce a Fresnel diffraction pattern. A portion of the beam travels through the aperture to a detector, spaced a known distance from the screen. The detector detects the central intensity of the beam. The distance from the object which causes the beam to be split to the target can then be calculated based upon the known wavelength, aperture radius, beam intensity, and distance from the detector to the screen. Several apparatus embodiments are disclosed for practicing the method embodiments of the present invention. 9 figs.

  7. Method and apparatus for making absolute range measurements

    DOEpatents

    Allison, Stephen W.; Cates, Michael R.; Key, William S.; Sanders, Alvin J.; Earl, Dennis D.

    1999-01-01

    This invention relates to a method and apparatus for making absolute distance or ranging measurements using Fresnel diffraction. The invention employs a source of electromagnetic radiation having a known wavelength or wavelength distribution, which sends a beam of electromagnetic radiation through an object which causes it to be split (hereinafter referred to as a "beamsplitter"), and then to a target. The beam is reflected from the target onto a screen containing an aperture spaced a known distance from the beamsplitter. The aperture is sized so as to produce a Fresnel diffraction pattern. A portion of the beam travels through the aperture to a detector, spaced a known distance from the screen. The detector detects the central intensity of the beam. The distance from the object which causes the beam to be split to the target can then be calculated based upon the known wavelength, aperture radius, beam intensity, and distance from the detector to the screen. Several apparatus embodiments are disclosed for practicing the method embodiments of the present invention.

  8. Relative and absolute intensity calibrations of a modern broadband echelle spectrometer

    NASA Astrophysics Data System (ADS)

    Bibinov, N.; Halfmann, H.; Awakowicz, P.; Wiesemann, K.

    2007-05-01

    We report on relative and absolute intensity calibrations of a modern broadband echelle spectrometer (type ESA 3000® trademark of LLA Instruments GmbH, Berlin) for use in the diagnostics of low-temperature plasma. This type of device measures simultaneously complete emission spectra in the spectral range from 200 to 800 nm with a spectral resolution of several picometres by using more than 90 spectral orders, causing a strongly structured efficiency function. The assumptions and approximations entering the calibration procedure under these conditions are discussed in section 3. For coping with the strongly structured efficiency function a continuum light source is needed, which covers the entire spectral range. Furthermore, the variation of its intensity must be low enough to ensure that neither statistical errors perturb the calibration in regions with low photon flux and/or low efficiency, nor local memory overflow in regions with high photon flux or high efficiency. In our case this requires that during calibration over the whole spectral range of the spectrometer the counts per pixel in one measurement vary at highest by a factor 10 to 12. Usual broadband light sources do not meet this latter requirement. We, therefore, use an uncalibrated 'composite' source, an adjustable combination of a standard tungsten strip lamp and a deuterium lamp, and calibrate the spectrometer in a two-step process against the tungsten strip lamp and well-known rovibrational intensity distributions in the emission spectra of NO and N2. We adjust the composite source in a way to produce a perturbation-free first approximation of an (uncalibrated) efficiency function, which is then corrected and thus calibrated by comparison with the (secondary) standards mentioned above. For absolute calibration we use the tungsten strip lamp. The uncertainty attained in this way for the relative calibration depends on the wavelength and varies between 5% and 10%. For the absolute calibration we

  9. Prediction of absolute infrared intensities for the fundamental vibrations of H2O2

    NASA Technical Reports Server (NTRS)

    Rogers, J. D.; Hillman, J. J.

    1981-01-01

    Absolute infrared intensities are predicted for the vibrational bands of gas-phase H2O2 by the use of a hydrogen atomic polar tensor transferred from the hydroxyl hydrogen atom of CH3OH. These predicted intensities are compared with intensities predicted by the use of a hydrogen atomic polar tensor transferred from H2O. The predicted relative intensities agree well with published spectra of gas-phase H2O2, and the predicted absolute intensities are expected to be accurate to within at least a factor of two. Among the vibrational degrees of freedom, the antisymmetric O-H bending mode nu(6) is found to be the strongest with a calculated intensity of 60.5 km/mole. The torsional band, a consequence of hindered rotation, is found to be the most intense fundamental with a predicted intensity of 120 km/mole. These results are compared with the recent absolute intensity determinations for the nu(6) band.

  10. Absolute photon-flux measurements in the vacuum ultraviolet

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.; Haddad, G. N.

    1974-01-01

    Absolute photon-flux measurements in the vacuum ultraviolet have extended to short wavelengths by use of rare-gas ionization chambers. The technique involves the measurement of the ion current as a function of the gas pressure in the ion chamber. The true value of the ion current, and hence the absolute photon flux, is obtained by extrapolating the ion current to zero gas pressure. Examples are given at 162 and 266 A. The short-wavelength limit is determined only by the sensitivity of the current-measuring apparatus and by present knowledge of the photoionization processes that occur in the rate gases.

  11. On the Absolute Continuity of the Blackwell Measure

    NASA Astrophysics Data System (ADS)

    Bárány, Balázs; Kolossváry, István

    2015-04-01

    In 1957, Blackwell expressed the entropy of hidden Markov chains using a measure which can be characterised as an invariant measure for an iterated function system with place-dependent weights. This measure, called the Blackwell measure, plays a central role in understanding the entropy rate and other important characteristics of fundamental models in information theory. We show that for a suitable set of parameter values the Blackwell measure is absolutely continuous for almost every parameter in the case of binary symmetric channels.

  12. Mathematical Model for Absolute Magnetic Measuring Systems in Industrial Applications

    NASA Astrophysics Data System (ADS)

    Fügenschuh, Armin; Fügenschuh, Marzena; Ludszuweit, Marina; Mojsic, Aleksandar; Sokół, Joanna

    2015-09-01

    Scales for measuring systems are either based on incremental or absolute measuring methods. Incremental scales need to initialize a measurement cycle at a reference point. From there, the position is computed by counting increments of a periodic graduation. Absolute methods do not need reference points, since the position can be read directly from the scale. The positions on the complete scales are encoded using two incremental tracks with different graduation. We present a new method for absolute measuring using only one track for position encoding up to micrometre range. Instead of the common perpendicular magnetic areas, we use a pattern of trapezoidal magnetic areas, to store more complex information. For positioning, we use the magnetic field where every position is characterized by a set of values measured by a hall sensor array. We implement a method for reconstruction of absolute positions from the set of unique measured values. We compare two patterns with respect to uniqueness, accuracy, stability and robustness of positioning. We discuss how stability and robustness are influenced by different errors during the measurement in real applications and how those errors can be compensated.

  13. Measurements of the reactor neutron power in absolute units

    SciTech Connect

    Lebedev, G. V.

    2015-12-15

    The neutron power of the reactor of the Yenisei space nuclear power plant is measured in absolute units using the modernized method of correlation analysis during the ground-based tests of the Yenisei prototypes. Results of the experiments are given. The desired result is obtained in a series of experiments carried out at the stage of the plant preparation for tests. The acceptability of experimental data is confirmed by the results of measuring the reactor neutron power in absolute units at the nominal level by the thermal balance during the life cycle tests of the ground prototypes.

  14. Europe's Other Poverty Measures: Absolute Thresholds Underlying Social Assistance

    ERIC Educational Resources Information Center

    Bavier, Richard

    2009-01-01

    The first thing many learn about international poverty measurement is that European nations apply a "relative" poverty threshold and that they also do a better job of reducing poverty. Unlike the European model, the "absolute" U.S. poverty threshold does not increase in real value when the nation's standard of living rises, even though it is…

  15. Urey: to measure the absolute age of Mars

    NASA Technical Reports Server (NTRS)

    Randolph, J. E.; Plescia, J.; Bar-Cohen, Y.; Bartlett, P.; Bickler, D.; Carlson, R.; Carr, G.; Fong, M.; Gronroos, H.; Guske, P. J.; Herring, M.; Javadi, H.; Johnson, D. W.; Larson, T.; Malaviarachchi, K.; Sherrit, S.; Stride, S.; Trebi-Ollennu, A.; Warwick, R.

    2003-01-01

    UREY, a proposed NASA Mars Scout mission will, for the first time, measure the absolute age of an identified igneous rock formation on Mars. By extension to relatively older and younger rock formations dated by remote sensing, these results will enable a new and better understanding of Martian geologic history.

  16. Absolute concentration measurements inside a jet plume using video digitization

    NASA Astrophysics Data System (ADS)

    Vauquelin, O.

    An experimental system based on digitized video image analysis is used to measure the local value of the concentration inside a plume. Experiments are carried out in a wind-tunnel for a smoke-seeded turbulent jet plume illuminated with a laser beam. Each test is filmed, subsequently video images are digitized and analysed in order to determine the smoke absolute concentration corresponding to each pixel gray level. This non-intrusive measurement technique is first calibrated and different laws connecting gray level to concentration are established. As a first application, concentration measurements are made inside a turbulent jet plume and compared with measurements conducted using a classic gas analysis method. We finally present and discuss the possibilities offered for the measurements of absolute concentration fluctuations.

  17. Absolute intensity calibration of two-channel prototype ITER vacuum ultraviolet spectrometer with a collimating mirror.

    NASA Astrophysics Data System (ADS)

    Seon, Changrae; Hong, Joohwan; Cheon, Munseong; Pak, Sunil; Lee, Hyeongon; Biel, Wolfgang; Barnsley, Robin

    2012-10-01

    To optimize the design of ITER vacuum ultraviolet (VUV) spectrometer, a two-channel prototype spectrometer was implemented with No. 3 (14.4 nm -- 31.8 nm) and No. 4 (29.0 nm -- 60.0 nm) among the five channels. The prototype is composed of a toroidal mirror, and two toroidal diffraction gratings and two different detectors of the back-illuminated CCD and the micro-channel plate (MCP). To verify each optical component, the absolute intensity calibration was performed using the calibrated hollow cathode lamp. Inverse sensitivities of each spectrometer were derived by dividing the incident photon numbers with the measured detector counts. The measured sensitivity values were consistent with the sensitivities calculated from the grating and the detector efficiencies. Consequently the calibration curves of the two-channel VUV spectrometer were provided, and the mirror reflectivity and the detector efficiency could be confirmed experimentally. For the application of the calibrated spectrometer, measurements of impurity lines in KSTAR plasmas were performed, and the line integrated emissivity was derived from the calibration curve during impurity injection experiments.

  18. Revised Pioneer 10 absolute electron intensities in the inner Jovian magnetosphere

    NASA Technical Reports Server (NTRS)

    Baker, D. N.; Van Allen, J. A.

    1977-01-01

    Improved techniques for the analysis of Pioneer 10 Jupiter encounter data are used to obtain significantly more reliable values for energetic electron (Ee less than 21 MeV) intensities within the inner magnetosphere. The revised absolute intensities of electrons in the energy range 0.06-21 MeV are less than previous estimates by factors as great as 10 for L not exceeding 6. Previously published intensities at greater radial distances for Ee less than 21 MeV and at all radial distances for Ee greater than 21 MeV are not affected by the revisions.

  19. Lens transmission measurement for an absolute radiation thermometer

    SciTech Connect

    Hao, X.; Yuan, Z.; Lu, X.

    2013-09-11

    The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10{sup −3} at 633 nm and 900 nm, respectively.

  20. An Absolute Measurement of Resonance-Resolved Electron Impact Excitation

    NASA Astrophysics Data System (ADS)

    Reisenfeld, Daniel Brett

    1998-11-01

    An experiment to measure electron-impact excitation (EIE) of multiply-charged ions is described. An absolute measurement has been carried out of the cross section for EIE of Si2+(3s2/ 1S/to3s3p/ 1P) from energies below threshold to 11 eV above. A beams modulation technique with inclined electron and ion beams was used. Radiation at 120.7 nm from the excited ions was detected using an absolutely calibrated optical system. The analysis of the experimental data requires a determination of the population fraction of the Si2+ (3s3p/ 3Po) metastable state in the incident ion beam, which was measured to be 0.210 ± 0.018. The data have been corrected for contributions to the signal from radiative decay following excitation from the metastable state to 3s3p1P and 3p2/ 3P, and excitation of the ground state to levels above 3s3p/ 1P. The experimental 0.56 ± 0.08 eV energy spread has allowed us to resolve complex resonance structure throughout the studied energy range. At the reported ±14% uncertainty level (90% confidence limit), the measured structure and absolute scale of the cross section are in good agreement with 12-state close-coupling R-matrix calculations.

  1. Absolute measurement of the extreme UV solar flux

    NASA Technical Reports Server (NTRS)

    Carlson, R. W.; Ogawa, H. S.; Judge, D. L.; Phillips, E.

    1984-01-01

    A windowless rare-gas ionization chamber has been developed to measure the absolute value of the solar extreme UV flux in the 50-575-A region. Successful results were obtained on a solar-pointing sounding rocket. The ionization chamber, operated in total absorption, is an inherently stable absolute detector of ionizing UV radiation and was designed to be independent of effects from secondary ionization and gas effusion. The net error of the measurement is + or - 7.3 percent, which is primarily due to residual outgassing in the instrument, other errors such as multiple ionization, photoelectron collection, and extrapolation to the zero atmospheric optical depth being small in comparison. For the day of the flight, Aug. 10, 1982, the solar irradiance (50-575 A), normalized to unit solar distance, was found to be 5.71 + or - 0.42 x 10 to the 10th photons per sq cm sec.

  2. Absolute equation of state measurements of iron using laser driven shocks

    NASA Astrophysics Data System (ADS)

    Benuzzi-Mounaix, A.; Koenig, M.; Huser, G.; Faral, B.; Batani, D.; Henry, E.; Tomasini, M.; Marchet, B.; Hall, T. A.; Boustie, M.; de Rességuier, Th.; Hallouin, M.; Guyot, F.; Andrault, D.; Charpin, Th.

    2002-06-01

    First absolute equation of state measurements obtained for iron with laser driven shock waves are presented. The shock velocity and the free surface velocity of compressed iron have been simultaneously measured by using a VISAR diagnostic, and step targets. The pressure range 1-8 Mbar has been investigated, which is directly relevant to planetary physics. The experiments have been performed at the Laboratoire pour l'Utilisation des Lasers Intenses of the Ecole Polytechnique.

  3. Seasonal absolute acoustic intensity, atmospheric forcing and currents in a tropical coral reef system

    NASA Astrophysics Data System (ADS)

    de Jesús Salas Pérez, José; Salas-Monreal, David; Monreal-Gómez, María Adela; Riveron-Enzastiga, Mayra Lorena; Llasat, Carme

    2012-03-01

    The seasonal patterns of marine circulation and biovolume were obtained from time-series measurements carried out in the "Parque Nacional Sistema Arrecifal Veracruzano" (PNSAV), located in the western continental shelf of the Gulf of Mexico, from June 2008 to September 2009. Two mechanisms were depicted as the responsible for the current pattern observed in the PNSAV and not only one as suggested in large-scale studies. The first mechanism is the wind generated currents. This mechanism by itself is responsible for up to 78% of total variation of the seasonal circulation in the PNSAV as estimated with the first mode of the EOF's (Empirical Orthogonal Functions), which was correlated (Normalized Lagged Correlation) with the north-south wind component. Therefore, the wind and the first mode were highly correlated for most of the year (r > 0.7). The second mode was attributed to the low frequency current, associated to the meso-scale circulation of the Gulf of Mexico, owing to the cyclonic eddy of the Campeche Bay. Both mechanisms were mostly observed throughout the year. Nevertheless, the cyclonic eddy of the Campeche Bay (meso-scale) was the first responsible for the current fluctuations observed during the summer of 2008 and 2009. The absolute acoustic intensity (plankton biovolumes) was highly correlated to currents, showing high spatial variability, attributed to advection produced by the meso-scale circulation and to river discharges, but also by eddy diffusion produced by atmospheric and coastal water fronts.

  4. Absolute phase recovery in structured light illumination systems: Sinusoidal vs. intensity discrete patterns

    NASA Astrophysics Data System (ADS)

    Porras-Aguilar, Rosario; Falaggis, Konstantinos

    2016-09-01

    Structured light illumination is a well-established technology for noncontact 3D surface measurements. A common challenge in those systems is to obtain the absolute surface information using few measurement frames. This work discusses techniques based on the projection of multiple sinusoidal fringe patterns with different fringe period, as well as the projection of intensity discrete Gray Code and grey-level coded patterns. The use of sinusoidal multi-frequency techniques has been since years an on-going area of research, where various algorithms have been developed based on beats, look-up tables, or number-theoretical approaches. This work shows that a related technique, the so-called algebraic reconstruction technique that is borrowed from the area of multi-wavelength interferometry can be used for this purpose. This approach provides a robust analytical solution to the phase-unwrapping problem. However, this work argues that despite these advances, the acquisition of additional phase maps obtained with different fringe periods requires too many measurement frames, and hence is inefficient. Motivated by that, this work proposes a new grey level coding scheme that uses only few measurement frames, overcomes typical defocus errors, and has an error detecting feature. The latter feature makes the need of separate error detecting algorithms obsolete. This so-called closed-loop space filling curve can be implemented with an arbitrary number of N grey-levels enabling to code up to (2N) code-words. The performance of this so-called closed-loop space filling curve is demonstrated using experimental data.

  5. Precision Absolute Beam Current Measurement of Low Power Electron Beam

    SciTech Connect

    Ali, M. M.; Bevins, M. E.; Degtiarenko, P.; Freyberger, A.; Krafft, G. A.

    2012-11-01

    Precise measurements of low power CW electron beam current for the Jefferson Lab Nuclear Physics program have been performed using a Tungsten calorimeter. This paper describes the rationale for the choice of the calorimeter technique, as well as the design and calibration of the device. The calorimeter is in use presently to provide a 1% absolute current measurement of CW electron beam with 50 to 500 nA of average beam current and 1-3 GeV beam energy. Results from these recent measurements will also be presented.

  6. OCT angiography by absolute intensity difference applied to normal and diseased human retinas

    PubMed Central

    Ruminski, Daniel; Sikorski, Bartosz L.; Bukowska, Danuta; Szkulmowski, Maciej; Krawiec, Krzysztof; Malukiewicz, Grazyna; Bieganowski, Lech; Wojtkowski, Maciej

    2015-01-01

    We compare four optical coherence tomography techniques for noninvasive visualization of microcapillary network in the human retina and murine cortex. We perform phantom studies to investigate contrast-to-noise ratio for angiographic images obtained with each of the algorithm. We show that the computationally simplest absolute intensity difference angiographic OCT algorithm that bases only on two cross-sectional intensity images may be successfully used in clinical study of healthy eyes and eyes with diabetic maculopathy and branch retinal vein occlusion. PMID:26309740

  7. Absolute measurements of nonlinear absorption near LIDT at 193 nm

    NASA Astrophysics Data System (ADS)

    Blaschke, Holger; Ristau, Detlev; Welsch, Eberhard; Apel, Oliver

    2001-04-01

    Previous investigations indicate that oxide coatings exhibit non-linear absorption phenomena below 200 nm. Hereby, absorption data of Al2O3 thin film coatings has been determined absolutely by laser calorimetry (LCA) at 193 nm in the low fluence regime. As an alternative, on the basis of the pulsed surface thermal lens technique (STL), photothermal measurements allow to determine the absorption relatively at fluence levels both in the subdamage fluence range far from the damage onset and close to the LIDT. By combining the two measurement techniques, the absolute determination of linear as well as multiphoton absorption can be achieved also in the vicinity of the laser damage fluences. This is of crucial interest because the initiation of damage onset can be observed immediately. Absolute absorption data of Al2O3 coatings at different laser fluences stating of some mJoule/cm2 will be presented for the wavelength 193 nm. Thus, the correlation between the increase of absorption and the onset of breakdown can be illustrated impressively. The evaluation and discussion of the experimental results are focused on the degree of non-linearity of the investigated absorption behavior of oxide single layers initiating the optical breakdown of UV oxide coatings.

  8. Absolute Line Intensities in the ν 3Band of 12CH 3F by Diode-Laser Spectroscopy

    NASA Astrophysics Data System (ADS)

    Lepère, Muriel; Blanquet, Ghislain; Walrand, Jacques

    1996-06-01

    Infrared absolute line intensities of the ν 3band of 12CH 3F have been measured around 9.5 μm using a diode-laser spectrometer. These line strengths were obtained from the equivalent width method and, for a few lines, by fitting a Rautian profile to the measured shape of the lines. From these results, we have deduced the vibrational bandstrength ( Sv0= 379.2 ± 5.9 cm -2·atm -1at 296 K) and the first Herman-Wallis factor (α = 0.35 × 10 -3± 0.10 × 10 -3).

  9. Strategy for the absolute neutron emission measurement on ITER.

    PubMed

    Sasao, M; Bertalot, L; Ishikawa, M; Popovichev, S

    2010-10-01

    Accuracy of 10% is demanded to the absolute fusion measurement on ITER. To achieve this accuracy, a functional combination of several types of neutron measurement subsystem, cross calibration among them, and in situ calibration are needed. Neutron transport calculation shows the suitable calibration source is a DT/DD neutron generator of source strength higher than 10(10) n/s (neutron/second) for DT and 10(8) n/s for DD. It will take eight weeks at the minimum with this source to calibrate flux monitors, profile monitors, and the activation system.

  10. Strategy for the absolute neutron emission measurement on ITER

    SciTech Connect

    Sasao, M.; Bertalot, L.; Ishikawa, M.; Popovichev, S.

    2010-10-15

    Accuracy of 10% is demanded to the absolute fusion measurement on ITER. To achieve this accuracy, a functional combination of several types of neutron measurement subsystem, cross calibration among them, and in situ calibration are needed. Neutron transport calculation shows the suitable calibration source is a DT/DD neutron generator of source strength higher than 10{sup 10} n/s (neutron/second) for DT and 10{sup 8} n/s for DD. It will take eight weeks at the minimum with this source to calibrate flux monitors, profile monitors, and the activation system.

  11. Absolute Bunch Length Measurements at the ALS by Incoherent Synchrotron Radiation Fluctuation Analysis

    SciTech Connect

    Filippetto, D.; Sannibale, F.; Zolotorev, Max Samuil; Stupakov, G.V.; /SLAC

    2008-01-24

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and tested a simple scheme based on this principle that allows for the absolute measurement of the bunch length. A description of the method and the experimental results are presented.

  12. Absolute measurement of the ultrafast nonlinear electronic and rovibrational response in H2 and D2

    NASA Astrophysics Data System (ADS)

    Wahlstrand, J. K.; Zahedpour, S.; Cheng, Y.-H.; Palastro, J. P.; Milchberg, H. M.

    2015-12-01

    The electronic, rotational, and vibrational components of the ultrafast optical nonlinearity in H2 and D2 are measured directly and absolutely at intensities up to the ionization threshold of ˜1014W/cm 2 . As the most basic nonlinear interactions of the simplest molecules exposed to high fields, these results constitute a benchmark for high-field laser-matter theory and simulation.

  13. Measuring Postglacial Rebound with GPS and Absolute Gravity

    NASA Technical Reports Server (NTRS)

    Larson, Kristine M.; vanDam, Tonie

    2000-01-01

    We compare vertical rates of deformation derived from continuous Global Positioning System (GPS) observations and episodic measurements of absolute gravity. We concentrate on four sites in a region of North America experiencing postglacial rebound. The rates of uplift from gravity and GPS agree within one standard deviation for all sites. The GPS vertical deformation rates are significantly more precise than the gravity rates, primarily because of the denser temporal spacing provided by continuous GPS tracking. We conclude that continuous GPS observations are more cost efficient and provide more precise estimates of vertical deformation rates than campaign style gravity observations where systematic errors are difficult to quantify.

  14. An absolute scale for measuring the utility of money

    NASA Astrophysics Data System (ADS)

    Thomas, P. J.

    2010-07-01

    Measurement of the utility of money is essential in the insurance industry, for prioritising public spending schemes and for the evaluation of decisions on protection systems in high-hazard industries. Up to this time, however, there has been no universally agreed measure for the utility of money, with many utility functions being in common use. In this paper, we shall derive a single family of utility functions, which have risk-aversion as the only free parameter. The fact that they return a utility of zero at their low, reference datum, either the utility of no money or of one unit of money, irrespective of the value of risk-aversion used, qualifies them to be regarded as absolute scales for the utility of money. Evidence of validation for the concept will be offered based on inferential measurements of risk-aversion, using diverse measurement data.

  15. Absolute Radiation Measurements in Earth and Mars Entry Conditions

    NASA Technical Reports Server (NTRS)

    Cruden, Brett A.

    2014-01-01

    This paper reports on the measurement of radiative heating for shock heated flows which simulate conditions for Mars and Earth entries. Radiation measurements are made in NASA Ames' Electric Arc Shock Tube at velocities from 3-15 km/s in mixtures of N2/O2 and CO2/N2/Ar. The technique and limitations of the measurement are summarized in some detail. The absolute measurements will be discussed in regards to spectral features, radiative magnitude and spatiotemporal trends. Via analysis of spectra it is possible to extract properties such as electron density, and rotational, vibrational and electronic temperatures. Relaxation behind the shock is analyzed to determine how these properties relax to equilibrium and are used to validate and refine kinetic models. It is found that, for some conditions, some of these values diverge from non-equilibrium indicating a lack of similarity between the shock tube and free flight conditions. Possible reasons for this are discussed.

  16. Absolute Line Intensities in the 2ν 02 Band of Cyanogen Chloride at 12.8 μm

    NASA Astrophysics Data System (ADS)

    Lepère, Muriel; Blanquet, Ghislain; Walrand, Jacques

    2000-05-01

    Absolute line intensities were measured at high resolution with a tunable diode laser. This work concerns the 2ν02 band of cyanogen chloride ClCN in the region 780 cm-1. Thirty-two absorption lines were recorded for the isotopomer 35ClCN and 26 lines for 37ClCN. From the analysis of these lines, we determined the bandstrengths: S0v = 19.14 cm-2 atm-1 for 35ClCN and S0v = 17.84 cm-2 atm-1 for 37ClCN.

  17. Absolute stress measurements at the rangely anticline, Northwestern Colorado

    USGS Publications Warehouse

    de la Cruz, R. V.; Raleigh, C.B.

    1972-01-01

    Five different methods of measuring absolute state of stress in rocks in situ were used at sites near Rangely, Colorado, and the results compared. For near-surface measurements, overcoring of the borehole-deformation gage is the most convenient and rapid means of obtaining reliable values for the magnitude and direction of the state of stress in rocks in situ. The magnitudes and directions of the principal stresses are compared to the geologic features of the different areas of measurement. The in situ stresses are consistent in orientation with the stress direction inferred from the earthquake focal-plane solutions and existing joint patterns but inconsistent with stress directions likely to have produced the Rangely anticline. ?? 1972.

  18. Full field imaging based instantaneous hyperspectral absolute refractive index measurement

    SciTech Connect

    Baba, Justin S; Boudreaux, Philip R

    2012-01-01

    Multispectral refractometers typically measure refractive index (RI) at discrete monochromatic wavelengths via a serial process. We report on the demonstration of a white light full field imaging based refractometer capable of instantaneous multispectral measurement of absolute RI of clear liquid/gel samples across the entire visible light spectrum. The broad optical bandwidth refractometer is capable of hyperspectral measurement of RI in the range 1.30 1.70 between 400nm 700nm with a maximum error of 0.0036 units (0.24% of actual) at 414nm for a = 1.50 sample. We present system design and calibration method details as well as results from a system validation sample.

  19. Absolute Measurements of Radiation Damage in Nanometer Thick Films

    PubMed Central

    Alizadeh, Elahe; Sanche, Léon

    2013-01-01

    We address the problem of absolute measurements of radiation damage in films of nanometer thicknesses. Thin films of DNA (~ 2–160nm) are deposited onto glass substrates and irradiated with varying doses of 1.5 keV X-rays under dry N2 at atmospheric pressure and room temperature. For each different thickness, the damage is assessed by measuring the loss of the supercoiled configuration as a function of incident photon fluence. From the exposure curves, the G-values are deduced, assuming that X-ray photons interacting with DNA, deposit all of their energy in the film. The results show that the G-value (i.e., damage per unit of deposited energy) increases with film thickness and reaches a plateau at 30±5 nm. This thickness dependence provides a correction factor to estimate the actual G-value for films with thicknesses below 30nm thickness. Thus, the absolute values of damage can be compared with that of films of any thickness under different experimental conditions. PMID:22562941

  20. Underwater measurements of muon intensity

    NASA Technical Reports Server (NTRS)

    Fedorov, V. M.; Pustovetov, V. P.; Trubkin, Y. A.; Kirilenkov, A. V.

    1985-01-01

    Experimental measurements of cosmic ray muon intensity deep underwater aimed at determining a muon absorption curve are of considerable interest, as they allow to reproduce independently the muon energy spectrum at sea level. The comparison of the muon absorption curve in sea water with that in rock makes it possible to determine muon energy losses caused by nuclear interactions. The data available on muon absorption in water and that in rock are not equivalent. Underground measurements are numerous and have been carried out down to the depth of approx. 15km w.e., whereas underwater muon intensity have been measured twice and only down to approx. 3km deep.

  1. Deconstructing European Poverty Measures: What Relative and Absolute Scales Measure

    ERIC Educational Resources Information Center

    Burkhauser, Richard V.

    2009-01-01

    Forster and d'Ercole (2009) outline the dominant method of conceptualization and operationalization of European poverty measures that informed the EU in its development of the questionnaire for the European Union--Survey of Income and Living Conditions (EU-SILC). They do so in the context of their explanation of how the Organization for Economic…

  2. Measurement of absolute T cell receptor rearrangement diversity.

    PubMed

    Baum, Paul D; Young, Jennifer J; McCune, Joseph M

    2011-05-31

    T cell receptor (TCR) diversity is critical for adaptive immunity. Existing methods for measuring such diversity are qualitative, expensive, and/or of uncertain accuracy. Here, we describe a method and associated reagents for estimating the absolute number of unique TCR Vβ rearrangements present in a given number of cells or volume of blood. Compared to next generation sequencing, this method is rapid, reproducible, and affordable. Diversity of a sample is calculated based on three independent measurements of one Vβ-Jβ family of TCR rearrangements at a time. The percentage of receptors using the given Vβ gene is determined by flow cytometric analysis of T cells stained with anti-Vβ family antibodies. The percentage of receptors using the Vβ gene in combination with the chosen Jβ gene is determined by quantitative PCR. Finally, the absolute clonal diversity of the Vβ-Jβ family is determined with the AmpliCot method of DNA hybridization kinetics, by interpolation relative to PCR standards of known sequence diversity. These three component measurements are reproducible and linear. Using titrations of known numbers of input cells, we show that the TCR diversity estimates obtained by this approach approximate expected values within a two-fold error, have a coefficient of variation of 20%, and yield similar results when different Vβ-Jβ pairs are chosen. The ability to obtain accurate measurements of the total number of different TCR gene rearrangements in a cell sample should be useful for basic studies of the adaptive immune system as well as in clinical studies of conditions such as HIV disease, transplantation, aging, and congenital immunodeficiencies. PMID:21385585

  3. Radio frequency controlled synthetic wavelength sweep for absolute distance measurement by optical interferometry

    SciTech Connect

    Le Floch, Sebastien; Salvade, Yves; Mitouassiwou, Rostand; Favre, Patrick

    2008-06-01

    We present a new technique applied to the variable optical synthetic wavelength generation in optical interferometry. It consists of a chain of optical injection locking among three lasers: first a distributed-feedback laser is used as a master to injection lock an intensity-modulated laser that is directly modulated around 15 GHz by a radio frequency generator on a sideband. A second distributed-feedback laser is injection locked on another sideband of the intensity-modulated laser. The variable synthetic wavelength for absolute distance measurement is simply generated by sweeping the radio frequency over a range of several hundred megahertz, which corresponds to the locking range of the two slave lasers. In this condition, the uncertainty of the variable synthetic wavelength is equivalent to the radio frequency uncertainty. This latter has a relative accuracy of 10{sup -7} or better, resulting in a resolution of {+-}25 {mu}m for distances exceeding tens of meters. The radio frequency generator produces a linear frequency sweep of 1 ms duration (i.e., exactly equal to one absolute distance measurement acquisition time), with frequency steps of about 1 MHz. Finally, results of absolute distance measurements for ranges up to 10 m are presented.

  4. Absolute intensities of CO2 lines in the 3140-3410/cm spectral region

    NASA Technical Reports Server (NTRS)

    Benner, D. Chris; Devi, V. Malathy; Ferry-Leeper, Penelope S.; Rinsland, Curtis P.

    1988-01-01

    Absolute intensities for 430 transitions belonging to eleven rotation-vibration bands of (C-12)(O-16)2, (C-13)(O-16)2, and (O-16)(C-18)(O-18) in the 3140-3410/cm spectral region have been determined by analyzing spectra recorded at 0.01/cm resolution with the Fourier transform spectrometer in the McMath solar telescope complex at the National Solar Observatory on Kitt Peak. The data were recorded at room temperature and low pressures (less than 10 torr) using a natural sample of carbon dioxide. Intensities were derived using a nonlinear least-squares spectral fitting procedure, and the values obtained for each band have been analyzed to determine the vibrational band intensity and nonrigid rotor coefficients. An alternative mathematical formulation is shown in the case of bands for which the Coriolis effect is large and the Q-branch line intensities were not determinable either because they were severely blended or absent from the spectra. Comparison are made between the results obtained in this study and other published values.

  5. Absolute intensities of CO(2) lines in the 3140-3410-cm(-1) spectral region.

    PubMed

    Benner, D C; Devi, V M; Rinsland, C P; Ferry-Leeper, P S

    1988-04-15

    Absolute intensities for 430 transitions belonging to eleven rotation-vibration bands of (12)C(16)O(2),(13)C(16)O(2) and(16)O(12)C(18)O in the 3140-3410-cm(-1) spectral region have been determined by analyzing spectra recorded at 0.01-cm(-1) resolution with the Fourier transform spectrometer in the McMath solar telescope complex at the National Solar Observatory on Kitt Peak. The data were recorded at room temperature and low pressures (<10 Torr) using a natural sample of carbon dioxide. Intensities were derived using a nonlinear least-squares spectral fitting procedure, and the values obtained for each band have been analyzed to determine the vibrational band intensity and nonrigid rotor coefficients. An alternative mathematical formulation is shown in the case of bands for which the Coriolis effect is large and the Q-branch line intensities were not determinate either because they were severely blended or absent from the spectra. Comparisons are made between the results obtained in this study and other published values.

  6. Lunar eclipse photometry: absolute luminance measurements and modeling.

    PubMed

    Hernitschek, Nina; Schmidt, Elmar; Vollmer, Michael

    2008-12-01

    The Moon's time-dependent luminance was determined during the 9 February 1990 and 3 March 2007 total lunar eclipses by using calibrated, industry standard photometers. After the results were corrected to unit air mass and to standard distances for both Moon and Sun, an absolute calibration was accomplished by using the Sun's known luminance and a pre-eclipse lunar albedo of approximately 13.5%. The measured minimum level of brightness in the total phase of both eclipses was relatively high, namely -3.32 m(vis) and -1.7 m(vis), which hints at the absence of pronounced stratospheric aerosol. The light curves were modeled in such a way as to let the Moon move through an artificial Earth shadow composed of a multitude of disk and ring zones, containing a relative luminance data set from an atmospheric radiative transfer calculation. PMID:19037352

  7. Lunar eclipse photometry: absolute luminance measurements and modeling.

    PubMed

    Hernitschek, Nina; Schmidt, Elmar; Vollmer, Michael

    2008-12-01

    The Moon's time-dependent luminance was determined during the 9 February 1990 and 3 March 2007 total lunar eclipses by using calibrated, industry standard photometers. After the results were corrected to unit air mass and to standard distances for both Moon and Sun, an absolute calibration was accomplished by using the Sun's known luminance and a pre-eclipse lunar albedo of approximately 13.5%. The measured minimum level of brightness in the total phase of both eclipses was relatively high, namely -3.32 m(vis) and -1.7 m(vis), which hints at the absence of pronounced stratospheric aerosol. The light curves were modeled in such a way as to let the Moon move through an artificial Earth shadow composed of a multitude of disk and ring zones, containing a relative luminance data set from an atmospheric radiative transfer calculation.

  8. Absolute measures of the completeness of the fossil record

    NASA Technical Reports Server (NTRS)

    Foote, M.; Sepkoski, J. J. Jr; Sepkoski JJ, J. r. (Principal Investigator)

    1999-01-01

    Measuring the completeness of the fossil record is essential to understanding evolution over long timescales, particularly when comparing evolutionary patterns among biological groups with different preservational properties. Completeness measures have been presented for various groups based on gaps in the stratigraphic ranges of fossil taxa and on hypothetical lineages implied by estimated evolutionary trees. Here we present and compare quantitative, widely applicable absolute measures of completeness at two taxonomic levels for a broader sample of higher taxa of marine animals than has previously been available. We provide an estimate of the probability of genus preservation per stratigraphic interval, and determine the proportion of living families with some fossil record. The two completeness measures use very different data and calculations. The probability of genus preservation depends almost entirely on the Palaeozoic and Mesozoic records, whereas the proportion of living families with a fossil record is influenced largely by Cenozoic data. These measurements are nonetheless highly correlated, with outliers quite explicable, and we find that completeness is rather high for many animal groups.

  9. Absolute measures of the completeness of the fossil record.

    PubMed

    Foote, M; Sepkoski, J J

    1999-04-01

    Measuring the completeness of the fossil record is essential to understanding evolution over long timescales, particularly when comparing evolutionary patterns among biological groups with different preservational properties. Completeness measures have been presented for various groups based on gaps in the stratigraphic ranges of fossil taxa and on hypothetical lineages implied by estimated evolutionary trees. Here we present and compare quantitative, widely applicable absolute measures of completeness at two taxonomic levels for a broader sample of higher taxa of marine animals than has previously been available. We provide an estimate of the probability of genus preservation per stratigraphic interval, and determine the proportion of living families with some fossil record. The two completeness measures use very different data and calculations. The probability of genus preservation depends almost entirely on the Palaeozoic and Mesozoic records, whereas the proportion of living families with a fossil record is influenced largely by Cenozoic data. These measurements are nonetheless highly correlated, with outliers quite explicable, and we find that completeness is rather high for many animal groups.

  10. Chiral isothiocyanates - An approach to determination of the absolute configuration using circular dichroism measurement

    NASA Astrophysics Data System (ADS)

    Michalski, Oskar; Cież, Dariusz

    2013-04-01

    Chiral alkyl 2-isothiocyanates have been obtained from enantiopure, aliphatic amines. ECD measurements allowed us to correlate an absolute configuration at C-2 with a sign of the Cotton effect (CE) observed for n-π* transition at the longer-wavelength range of the spectrum. Chirooptical data calculated for all enantiomers were consistent with the measured CE values and indicated that the weak absorption band at 240 nm could give an important information concerning the stereochemistry of simple, chiral isothiocyanates. Optically active esters of 2-isothiocyanatocarboxylic acids, prepared from α-amino acids, showed two absorption bands located over 195 nm. The more intensive band near 200 nm and the weak absorption located at 250 nm were related to n-π* transitions in NCS group. TD DFT calculations carried out for methyl esters of 2-isothiocyanatocarboxylic acids showed the correlation between signs of CE determined for both absorption bands, and the absolute configuration on C-2.

  11. CARES: Completely Automated Robust Edge Snapper for carotid ultrasound IMT measurement on a multi-institutional database of 300 images: a two stage system combining an intensity-based feature approach with first order absolute moments

    NASA Astrophysics Data System (ADS)

    Molinari, Filippo; Acharya, Rajendra; Zeng, Guang; Suri, Jasjit S.

    2011-03-01

    The carotid intima-media thickness (IMT) is the most used marker for the progression of atherosclerosis and onset of the cardiovascular diseases. Computer-aided measurements improve accuracy, but usually require user interaction. In this paper we characterized a new and completely automated technique for carotid segmentation and IMT measurement based on the merits of two previously developed techniques. We used an integrated approach of intelligent image feature extraction and line fitting for automatically locating the carotid artery in the image frame, followed by wall interfaces extraction based on Gaussian edge operator. We called our system - CARES. We validated the CARES on a multi-institutional database of 300 carotid ultrasound images. IMT measurement bias was 0.032 +/- 0.141 mm, better than other automated techniques and comparable to that of user-driven methodologies. Our novel approach of CARES processed 96% of the images leading to the figure of merit to be 95.7%. CARES ensured complete automation and high accuracy in IMT measurement; hence it could be a suitable clinical tool for processing of large datasets in multicenter studies involving atherosclerosis.pre-

  12. Absolute Thermal SST Measurements over the Deepwater Horizon Oil Spill

    NASA Astrophysics Data System (ADS)

    Good, W. S.; Warden, R.; Kaptchen, P. F.; Finch, T.; Emery, W. J.

    2010-12-01

    Climate monitoring and natural disaster rapid assessment require baseline measurements that can be tracked over time to distinguish anthropogenic versus natural changes to the Earth system. Disasters like the Deepwater Horizon Oil Spill require constant monitoring to assess the potential environmental and economic impacts. Absolute calibration and validation of Earth-observing sensors is needed to allow for comparison of temporally separated data sets and provide accurate information to policy makers. The Ball Experimental Sea Surface Temperature (BESST) radiometer was designed and built by Ball Aerospace to provide a well calibrated measure of sea surface temperature (SST) from an unmanned aerial system (UAS). Currently, emissive skin SST observed by satellite infrared radiometers is validated by shipborne instruments that are expensive to deploy and can only take a few data samples along the ship track to overlap within a single satellite pixel. Implementation on a UAS will allow BESST to map the full footprint of a satellite pixel and perform averaging to remove any local variability due to the difference in footprint size of the instruments. It also enables the capability to study this sub-pixel variability to determine if smaller scale effects need to be accounted for in models to improve forecasting of ocean events. In addition to satellite sensor validation, BESST can distinguish meter scale variations in SST which could be used to remotely monitor and assess thermal pollution in rivers and coastal areas as well as study diurnal and seasonal changes to bodies of water that impact the ocean ecosystem. BESST was recently deployed on a conventional Twin Otter airplane for measurements over the Gulf of Mexico to access the thermal properties of the ocean surface being affected by the oil spill. Results of these measurements will be presented along with ancillary sensor data used to eliminate false signals including UV and Synthetic Aperture Radar (SAR

  13. Muscle Activation During Exercise in Severe Acute Hypoxia: Role of Absolute and Relative Intensity

    PubMed Central

    Torres-Peralta, Rafael; Losa-Reyna, José; González-Izal, Miriam; Perez-Suarez, Ismael; Calle-Herrero, Jaime; Izquierdo, Mikel

    2014-01-01

    Abstract Torres-Peralta, Rafael, José Losa-Reyna, Miriam González-Izal, Ismael Perez-Suarez, Jaime Calle-Herrero, Mikel Izquierdo, and José A.L. Calbet. Muscle activation during exercise in severe acute hypoxia: Role of absolute and relative intensity. High Alt Med Biol 15:472–482, 2014.—The aim of this study was to determine the influence of severe acute hypoxia on muscle activation during whole body dynamic exercise. Eleven young men performed four incremental cycle ergometer tests to exhaustion breathing normoxic (FIo2=0.21, two tests) or hypoxic gas (FIo2=0.108, two tests). Surface electromyography (EMG) activities of rectus femoris (RF), vastus medialis (VL), vastus lateralis (VL), and biceps femoris (BF) were recorded. The two normoxic and the two hypoxic tests were averaged to reduce EMG variability. Peak Vo2 was 34% lower in hypoxia than in normoxia (p<0.05). The EMG root mean square (RMS) increased with exercise intensity in all muscles (p<0.05), with greater effect in hypoxia than in normoxia in the RF and VM (p<0.05), and a similar trend in VL (p=0.10). At the same relative intensity, the RMS was greater in normoxia than in hypoxia in RF, VL, and BF (p<0.05), with a similar trend in VM (p=0.08). Median frequency increased with exercise intensity (p<0.05), and was higher in hypoxia than in normoxia in VL (p<0.05). Muscle contraction burst duration increased with exercise intensity in VM and VL (p<0.05), without clear effects of FIo2. No significant FIo2 effects on frequency domain indices were observed when compared at the same relative intensity. In conclusion, muscle activation during whole body exercise increases almost linearly with exercise intensity, following a muscle-specific pattern, which is adjusted depending on the FIo2 and the relative intensity of exercise. Both VL and VM are increasingly involved in power output generation with the increase of intensity and the reduction in FIo2. PMID:25225839

  14. Laser interferometry method for absolute measurement of the acceleration of gravity

    NASA Technical Reports Server (NTRS)

    Hudson, O. K.

    1971-01-01

    Gravimeter permits more accurate and precise absolute measurement of g without reference to Potsdam values as absolute standards. Device is basically Michelson laser beam interferometer in which one arm is mass fitted with corner cube reflector.

  15. Absolute Rovibrational Intensities of C-12O2-16 Absorption Bands in the 3090-3850/ CM Spectral Region

    NASA Technical Reports Server (NTRS)

    Devi, V. Malathy; Benner, D. Chris; Rinsland, Curtis P.; Smith, Mary Ann H.

    1998-01-01

    A multispectrum nonlinear least-squares fitting technique has been used to determine the absolute intensities for approximately 1500 spectral lines in 36 vibration - rotation bands Of C-12O2-16 between 3090 and 3850/ cm. A total of six absorption spectra of a high- purity (99.995% minimum) natural sample of carbon dioxide were used in the analysis. The spectral data (0.01/cm resolution) were recorded at room temperature and low pressure (1 to 10 Torr) using the McMath-Pierce Fourier transform spectrometer of the National Solar Observatory (NSO) on Kitt Peak. The absorption path lengths for these spectra varied between 24.86 and 385.76 m. The first experimental determination of the intensity of the theoretically predicted 2(nu)(sub 2, sup 2) + nu(sub 3) "forbidden" band has been made. The measured line intensities obtained for each band have been analyzed to determine the vibrational band intensity, S(sub nu), in /cm/( molecule/sq cm) at 296 K, square of the rotationless transition dipole moment |R|(exp 2) in Debye, as well as the nonrigid rotor coefficients. The results are compared to the values listed in the 1996 HITRAN database which are obtained using the direct numerical diagonalization (DND) technique as well as to other published values where available.

  16. Embedded north-seeker for automatic absolute magnetic DI measurements

    NASA Astrophysics Data System (ADS)

    Gonsette, Alexandre; Rasson, Jean

    2014-05-01

    In magnetic observatory Earth magnetic field is recorded with a resolution of 0.1nT for 1min sampling (new standards impose 1pT for 1s sampling). The method universally adopted for measuring it is a combination of three instruments. Vectorial magnetometer (variometer) records variations of the three components around a reference value or a baseline. A proton or an overhauser magnetometer is an absolute instrument able to measure the modulus of the field and used to determine the F component baseline of the variometer. The declination and inclination baselines require a manual procedure to be computed. An operator manipulates a non-magnetic theodolite (also called a DIFlux) to measure the D and I angles in different configurations with a resolution of a few arcsec. The AutoDIF is a non-magnetic automatic DIFlux using the same protocol as the manual procedure. The declination defined according to the true north is determined by means of a target pointing system. Even if the technique is fast and accurate, it becomes problematic in case of unmanned deployment. In particular the area between the target and the DIFlux is out of control. Snow storm, fog, vegetation or condensation on windows are examples of perturbation preventing for finding the target. It is obvious in case of (future) seafloor observatories. A FOG based north-seeker has been implemented and mounted on the AutoDIF. The first results using a low cost gyro don't meet the Intermagnet specifications yet but are however hopeful. A 0.1° standard deviation has been reached and statistically reduced to 0.01° after less than two days in laboratory. The magnetic disturbance of the sensor is taken into account and compensated by the measurement protocol.

  17. Progress Toward an Absolute Measurement of Electron Impact Excitation of Si^2+

    NASA Astrophysics Data System (ADS)

    Reisenfeld, D. B.; Janzen, P. H.; Gardner, L. D.; Kohl, J. L.

    1997-04-01

    We are in the process of measuring the electron impact excitation (EIE) absolute rate coefficients for Si^2+(3s^2 ^1S - 3s3p ^1P) and Si^2+(3s3p ^3P^o - 3p^2 ^3P) for energies near threshold. A beams modulation technique with inclined electron and ion beams is being used. The radiation from the excited ions at λ 120.6 nm and λ 130.0 nm is detected using an absolutely calibrated optical system that subtends slightly over π steradians. The population of the Si^2+(3s3p ^3P^o) metastable state in the incident ion beam is determined by making an absolute measurement of the intensity of the λ 189.2 nm light from the beam due to radiative decay of the metastable state(G. P. Layfatis and J. L. Kohl, Phys. Rev. A 36), 59 (1987).. Because of the high density of overlapping resonances above threshold, the cross sections should exhibit a complex energy dependence(D. C. Griffin et al)., Phys. Rev. A 47, 2871 (1993).. We expect to resolve some of this structure. Research progress and the experimental apparatus will be described. There are no previous measurements of EIE in a Mg-like system, nor of EIE in a metastable ion. This work was supported in part by NASA Supporting Research and Technology Program in Solar Physics grant NAGW-1687 and NASA Training Grant NGT-51081.

  18. Preliminary OARE absolute acceleration measurements on STS-50

    NASA Technical Reports Server (NTRS)

    Blanchard, Robert C.; Nicholson, John Y.; Ritter, James

    1993-01-01

    On-orbit Orbital Acceleration Research Experiment (OARE) data on STS-50 was examined in detail during a 2-day time period. Absolute acceleration levels were derived at the OARE location, the orbiter center-of-gravity, and at the STS-50 spacelab Crystal Growth Facility. The tri-axial OARE raw acceleration measurements (i.e., telemetered data) during the interval were filtered using a sliding trimmed mean filter in order to remove large acceleration spikes (e.g., thrusters) and reduce the noise. Twelve OARE measured biases in each acceleration channel during the 2-day interval were analyzed and applied to the filtered data. Similarly, the in situ measured x-axis scale factors in the sensor's most sensitive range were also analyzed and applied to the data. Due to equipment problem(s) on this flight, both y- and z- axis sensitive range scale factors were determined in a separate process (using the OARE maneuver data) and subsequently applied to the data. All known significant low-frequency corrections at the OARE location (i.e., both vertical and horizontal gravity-gradient, and rotational effects) were removed from the filtered data in order to produce the acceleration components at the orbiter's center-of-gravity, which are the aerodynamic signals along each body axes. Results indicate that there is a force of unknown origin being applied to the Orbiter in addition to the aerodynamic forces. The OARE instrument and all known gravitational and electromagnetic forces were reexamined, but none produce the observed effect. Thus, it is tentatively concluded that the Orbiter is creating the environment observed.

  19. a Portable Apparatus for Absolute Measurements of the Earth's Gravity.

    NASA Astrophysics Data System (ADS)

    Zumberge, Mark Andrew

    We have developed a new, portable apparatus for making absolute measurements of the acceleration due to the earth's gravity. We use the method of interferometrically determining the acceleration of a freely falling corner -cube prism. The falling object is surrounded by a chamber which is driven vertically inside a fixed vacuum chamber. This falling chamber is servoed to track the falling corner -cube to shield it from drag due to background gas. In addition, the drag-free falling chamber removes the need for a magnetic release, shields the falling object from electrostatic forces, and provides a means of both gently arresting the falling object and quickly returning it to its start position, to allow rapid acquisition of data. A synthesized long period isolation device reduces the noise due to seismic oscillations. A new type of Zeeman laser is used as the light source in the interferometer, and is compared with the wavelength of an iodine stabilized laser. The times of occurrence of 45 interference fringes are measured to within 0.2 nsec over a 20 cm drop and are fit to a quadratic by an on-line minicomputer. 150 drops can be made in ten minutes resulting in a value of g having a precision of 3 to 6 parts in 10('9). Systematic errors have been determined to be less than 5 parts in 10('9) through extensive tests. Three months of gravity data have been obtained with a reproducibility ranging from 5 to 10 parts in 10('9). The apparatus has been designed to be easily portable. Field measurements are planned for the immediate future. An accuracy of 6 parts in 10('9) corresponds to a height sensitivity of 2 cm. Vertical motions in the earth's crust and tectonic density changes that may precede earthquakes are to be investigated using this apparatus.

  20. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    NASA Astrophysics Data System (ADS)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  1. Absolute pulse energy measurements of soft x-rays at the Linac Coherent Light Source.

    PubMed

    Tiedtke, K; Sorokin, A A; Jastrow, U; Juranić, P; Kreis, S; Gerken, N; Richter, M; Arp, U; Feng, Y; Nordlund, D; Soufli, R; Fernández-Perea, M; Juha, L; Heimann, P; Nagler, B; Lee, H J; Mack, S; Cammarata, M; Krupin, O; Messerschmidt, M; Holmes, M; Rowen, M; Schlotter, W; Moeller, S; Turner, J J

    2014-09-01

    This paper reports novel measurements of x-ray optical radiation on an absolute scale from the intense and ultra-short radiation generated in the soft x-ray regime of a free electron laser. We give a brief description of the detection principle for radiation measurements which was specifically adapted for this photon energy range. We present data characterizing the soft x-ray instrument at the Linac Coherent Light Source (LCLS) with respect to the radiant power output and transmission by using an absolute detector temporarily placed at the downstream end of the instrument. This provides an estimation of the reflectivity of all x-ray optical elements in the beamline and provides the absolute photon number per bandwidth per pulse. This parameter is important for many experiments that need to understand the trade-offs between high energy resolution and high flux, such as experiments focused on studying materials via resonant processes. Furthermore, the results are compared with the LCLS diagnostic gas detectors to test the limits of linearity, and observations are reported on radiation contamination from spontaneous undulator radiation and higher harmonic content. PMID:25321502

  2. Rotational positioning measurement for the absolute angle based on a hetero-core fiber optics sensor

    NASA Astrophysics Data System (ADS)

    Nishiyama, Michiko; Watanabe, Kazuhiro

    2009-10-01

    We proposed a new approach to measure the rotational angle and describe how the rotational positioning sensor could be devised arranging the hetero-core fiber-optic macro-bending sensors in terms of detecting the absolute rotational angle. The hetero-core fiber optic sensor has many advantages such as ability of macro-bend sensing with optical intensity-based measurement, single-mode transmission basis and independence of temperature fluctuation for external environment. Therefore, it is suitable that the rotational positioning sensor is fabricated with the hetero-core fiber-optic technique. We designed two types of the absolute rotational position sensor modules to convert the absolute rotational angle to the displacement. The result showed that the proposed rotational positioning modules were sufficiently sensitive to the given rotational angle with monotonic loss change characteristics. The hetero-core rotational positioning sensors were successfully perceptive with typical sensitivities approximately 0.77 and 0.71 dB in the rotational angle ranges of 60 - 360 and 60 - 180 degrees. The deviation of the module in the range of 60 - 180 degrees induced 1.74 % that corresponded to 2.13 degrees.

  3. Raman intensities of liquids: Absolute scattering activities and electro-optical parameters (EOPs) of arsenate and selenate ions in aqueous solutions

    NASA Astrophysics Data System (ADS)

    Eysel, Hans H.; Wagner, Rüdiger

    1993-04-01

    Absolute Raman scattering activities of aqueous solutions of sodium arsenate and sodium selenate have been measured against NaClO 4 as an external standard. Electro-optical parameters (EOPs) for the AsO and SeO bonds were calculated. Changes of the previously published force fields (GVFF) were necessary to adjust the eigenvectors to the experimental frequencies and intensities in aqueous environment. Equilibrium bond polarizabilities were estimated from refractive index measurements in connection with Raman intensities of bending modes. The EOPs of these two isoelectronic compounds are discussed in comparison with the series phosphate, sulphate, perchlorate.

  4. A novel method to determine the electron temperature and density from the absolute intensity of line and continuum emission: application to atmospheric microwave induced Ar plasmas

    NASA Astrophysics Data System (ADS)

    Iordanova, E.; Palomares, J. M.; Gamero, A.; Sola, A.; van der Mullen, J. J. A. M.

    2009-08-01

    An absolute intensity measurement (AIM) technique is presented that combines the absolute measurements of the line and the continuum emitted by strongly ionizing argon plasmas. AIM is an iterative combination of the absolute line intensity-collisional radiative model (ALI-CRM) and the absolute continuum intensity (ACI) method. The basis of ALI-CRM is that the excitation temperature T13 determined by the method of ALI is transformed into the electron temperature Te using a CRM. This gives Te as a weak function of electron density ne. The ACI method is based on the absolute value of the continuum radiation and determines the electron density in a way that depends on Te. The iterative combination gives ne and Te. As a case study the AIM method is applied to plasmas created by torche à injection axiale (TIA) at atmospheric pressure and fixed frequency at 2.45 GHz. The standard operating settings are a gas flow of 1 slm and a power of 800 W; the measurements have been performed at a position of 1 mm above the nozzle. With AIM we found an electron temperature of 1.2 eV and electron density values around 1021 m-3. There is not much dependence of these values on the plasma control parameters (power and gas flow). From the error analysis we can conclude that the determination of Te is within 7% and thus rather accurate but comparison with other studies shows strong deviations. The ne determination comes with an error of 40% but is in reasonable agreement with other experimental results.

  5. Absolute thickness metrology with submicrometer accuracy using a low-coherence distance measuring interferometer.

    PubMed

    Zhao, Yang; Schmidt, Greg; Moore, Duncan T; Ellis, Jonathan D

    2015-09-01

    Absolute physical thickness across the sample aperture is critical in determining the index of a refraction profile from the optical path length profile for gradient index (GRIN) materials, which have a designed inhomogeneous refractive index. Motivated by this application, instrumentation was established to measure the absolute thickness of samples with nominally plane-parallel surfaces up to 50 mm thick. The current system is capable of measuring absolute thickness with 120 nm (1σ) repeatability and submicrometer expanded measurement uncertainty. Beside GRIN materials, this method is also capable of measuring other inhomogeneous and opaque materials. PMID:26368894

  6. The measurement of absolute absorption of millimeter radiation in gases - The absorption of CO and O2

    NASA Technical Reports Server (NTRS)

    Read, William G.; Cohen, Edward A.; Pickett, Herbert M.; Hillig, Kurt W., II

    1988-01-01

    An apparatus is described that will measure absolute absorption of millimeter radiation in gases. The method measures the change in the quality factor of a Fabry-Perot resonator with and without gas present. The magnitude of the change is interpreted in terms of the absorption of the lossy medium inside the resonator. Experiments have been performed on the 115-GHz CO line and the 119-GHz O2 line at two different temperatures to determine the linewidth parameter and the peak absorption value. These numbers can be combined to give the integrated intensity which can be accurately calculated from results of spectroscopy measurements. The CO results are within 2 percent percent of theoretically predicted valves. Measurements on O2 have shown that absorption can be measured as accurately as 0.5 dB/km with this technique. Results have been obtained for oxygen absolute absorption in the 60-80-GHz region.

  7. Absolute geomagnetic intensity determinations on Formative potsherds (1400-700 BC) from the Oaxaca Valley, Southwestern Mexico

    NASA Astrophysics Data System (ADS)

    Pétronille, Marie; Goguitchaichvili, Avto; Morales, Juan; Carvallo, Claire; Hueda-Tanabe, Yuki

    2012-11-01

    New Thellier-Coe archeointensity determinations have been measured on 15 potsherds from the Oaxaca Valley belonging to three of the four Formative Periods (Pre-Classical) of Mesoamerica, spanning 1400-700 BC. Seven of these are considered to be reliable and indicate a geomagnetic field strength of about 30 μT. This value is some 75% of the present geomagnetic field strength but is in agreement with the absolute intensities predicted from global models for this time and location, and consistent with coeval published determinations. These data thus provide significant evidence for the geomagnetic field strength in an area and for a time that was previously poorly constrained, thus providing an important contribution towards establishing a local master curve for the last 3500 yr. When established, such a curve would be a useful dating tool and also enable establishing for field strength correlations with climatic events and civilization evolutions in a region that is particularly strong in archeological and geological features. Such potential is examined for aridity events, although such observations can only be considered tentative at this stage.

  8. Absolute integrated intensity and individual line parameters for the 6.2-micron band of NO2. [in solar spectrum

    NASA Technical Reports Server (NTRS)

    Goldman, A.; Bonomo, F. S.; Williams, W. J.; Murcray, D. G.; Snider, D. E.

    1975-01-01

    The absolute integrated intensity of the 6.2-micron band of NO2 at 40 C was determined from quantitative spectra at about 10 per cm resolution by the spectral band model technique. A value of 1430 plus or minus 300 per sq cm per atm was obtained. Individual line parameters, positions, intensities, and ground-state energies were derived, and line-by-line calculations were compared with the band model results and with the quantitative spectra obtained at about 0.5 per cm resolution.

  9. Calibrating X-ray Imaging Devices for Accurate Intensity Measurement

    SciTech Connect

    Haugh, M. J.

    2011-07-28

    The purpose of the project presented is to develop methods to accurately calibrate X-ray imaging devices. The approach was to develop X-ray source systems suitable for this endeavor and to develop methods to calibrate solid state detectors to measure source intensity. NSTec X-ray sources used for the absolute calibration of cameras are described, as well as the method of calibrating the source by calibrating the detectors. The work resulted in calibration measurements for several types of X-ray cameras. X-ray camera calibration measured efficiency and efficiency variation over the CCD. Camera types calibrated include: CCD, CID, back thinned (back illuminated), front illuminated.

  10. Absolute beam emittance measurements at RHIC using ionization profile monitors

    SciTech Connect

    Minty, M.; Connolly, R; Liu, C.; Summers, T.; Tepikian, S.

    2014-08-15

    In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

  11. Technological Basis and Scientific Returns for Absolutely Accurate Measurements

    NASA Astrophysics Data System (ADS)

    Dykema, J. A.; Anderson, J.

    2011-12-01

    The 2006 NRC Decadal Survey fostered a new appreciation for societal objectives as a driving motivation for Earth science. Many high-priority societal objectives are dependent on predictions of weather and climate. These predictions are based on numerical models, which derive from approximate representations of well-founded physics and chemistry on space and timescales appropriate to global and regional prediction. These laws of chemistry and physics in turn have a well-defined quantitative relationship with physical measurement units, provided these measurement units are linked to international measurement standards that are the foundation of contemporary measurement science and standards for engineering and commerce. Without this linkage, measurements have an ambiguous relationship to scientific principles that introduces avoidable uncertainty in analyses, predictions, and improved understanding of the Earth system. Since the improvement of climate and weather prediction is fundamentally dependent on the improvement of the representation of physical processes, measurement systems that reduce the ambiguity between physical truth and observations represent an essential component of a national strategy for understanding and living with the Earth system. This paper examines the technological basis and potential science returns of sensors that make measurements that are quantitatively tied on-orbit to international measurement standards, and thus testable to systematic errors. This measurement strategy provides several distinct benefits. First, because of the quantitative relationship between these international measurement standards and fundamental physical constants, measurements of this type accurately capture the true physical and chemical behavior of the climate system and are not subject to adjustment due to excluded measurement physics or instrumental artifacts. In addition, such measurements can be reproduced by scientists anywhere in the world, at any time

  12. Superheterodyne configuration for two-wavelength interferometry applied to absolute distance measurement

    SciTech Connect

    Le Floch, Sebastien; Salvade, Yves; Droz, Nathalie; Mitouassiwou, Rostand; Favre, Patrick

    2010-02-01

    We present a new superheterodyne technique for long-distance measurements by two-wavelength interferometry (TWI). While conventional systems use two acousto-optic modulators to generate two different heterodyne frequencies, here the two frequencies result from synchronized sweeps of optical and radio frequencies. A distributed feedback laser source is injected in an intensity modulator that is driven at the half-wave voltage mode. A radio-frequency signal is applied to this intensity modulator to generate two optical sidebands around the optical carrier. This applied radio frequency consists of a digital ramp between 13 and 15 GHz, with 1 ms duration and with an accuracy of better than 1 ppm. Simultaneously, the laser source is frequency modulated by a current modulation that is synchronized on the radio-frequency ramp as well as on a triangle waveform. These two frequency-swept optical signals at the output of the modulator illuminate a Michelson interferometer and create two distinct distance-dependent heterodyne frequencies on the photodetector. The superheterodyne signal is then detected and bandpass filtered to retrieve the absolute distance measurement. Experiments between 1 and 15 m confirm the validity of this new concept, leading to a distance accuracy of {+-} 50 {mu}m for a 1 ms acquisition time.

  13. Absolute intensities for the Q-branch of the 3 nu(sub 2) (-) nu(sub 1) (465.161/cm) band of nitrous oxide

    NASA Technical Reports Server (NTRS)

    Sirota, J. Marcos; Reuter, Dennis C.

    1993-01-01

    The absolute intensities of four lines, Q 15-Q 18 in the 03(sup 1)0-10(sup 0)0 band, of N2O have been measured using a tunable diode laser spectrometer at temperatures between 380 and 420 K and pressures between 4 and 15 torr. Even though these transitions are weak and produced only about 2% of absorption at the line center for a pathlength of 52 m, they were measured with a signal to noise ratio of about 20 due to the high sensitivity of the instrument. The band strength derived is 1.03 x 10(exp -24) cm/molec at 296 K.

  14. Improve the Absolute Accuracy of Ozone Intensities in the 9-11 μm Region via Mw/ir Multi-Wavelength Spectroscopy

    NASA Astrophysics Data System (ADS)

    Yu, Shanshan; Drouin, Brian

    2016-06-01

    Ozone (O_3) is crucial for studies of air quality, human and crop health, and radiative forcing. Spectroscopic remote sensing techniques have been extensively employed to investigate ozone globally and regionally. Infrared intensities of ≤1% accuracy are desired by the remote sensing community. The accuracy of the current state-of-the-art infrared ozone intensities is on the order of 4-10%, resulting in ad hoc intensity scaling factors for consistent atmospheric retrievals. The large uncertainties on the infrared ozone intensities arise from the fact that pure ozone is very difficult to generate and sustain in the laboratory. Best estimates have employed IR/UV cross beam experiments to determine the accurate O_3 volume mixing ratio of the sample through its standard cross section value at 254 nm. This presentation reports our effort to improve the absolute accuracy of ozone intensities in the 9-11 μm region via a transfer of the precision of the rotational dipole moment onto the infrared measurement (MW/IR). Our approach was to use MW/IR cross beam experiments and determine the O_3 mixing ratio through alternately measuring pure rotation ozone lines from 692 to 779 GHz. The uncertainty of these pure rotation line intensities is better than 0.1%. The sample cell was a slow flow cross cell and the total pressure inside the sample cell was maintained constant through a proportional-integral-derivative (PID) flow control. Five infrared O_3 spectra were obtained, with a path length of 3.74 m, pressures ranging from 30 to 120 mTorr, and mixing ratio ranging from 0.5 to 0.9. A multi spectrum fitting technique was employed to fit all the FTS spectra simultaneously. The results show that we can determine intensities of the 9.6μm band with absolute accuracy better than 4%.

  15. Saturation Dynamics Measures Absolute Cross Section and Generates Contrast within a Neuron.

    PubMed

    Kumar, Suraj; Singh, Aditya; Singh, Vijay R; George, Jude B; Balaji, J

    2016-09-20

    The intensity required to optically saturate a chromophore is a molecular property that is determined by its absorption cross section (σ) and the excited state lifetime. We present an analytical description of such a system and show that fluorescence around the onset of saturation is characterized by product of absorption cross section and lifetime. Using this approach we formulate a generalized method for measuring the multiphoton cross section of fluorophores and use it to obtain the absolute three-photon cross-section spectra of tryptophan. We find that the tryptophan three-photon cross section ranges from 0.28 S.I. units (m(6)s(2)photon(-2)) at 870 nm to 20 S.I. units at 740 nm. Further, we show that the product of molecular rate of excitation and de-excitation, denoted as β, serves as a vital contrasting agent for imaging local environment. Our contrast parameter, β, is related to fraction of the population present in the excited state and is independent of the fluorophore concentration. We show that β-imaging can be carried out in a regular two-photon microscope setup through a series of intensity scans. Using enhanced green fluorescent protein (EGFP) fluorescence from the brain slices of Thy-1 EGFP transgenic mice, we show that there is an inherent, concentration independent, variation in contrast across the soma and the dendrite.

  16. Saturation Dynamics Measures Absolute Cross Section and Generates Contrast within a Neuron.

    PubMed

    Kumar, Suraj; Singh, Aditya; Singh, Vijay R; George, Jude B; Balaji, J

    2016-09-20

    The intensity required to optically saturate a chromophore is a molecular property that is determined by its absorption cross section (σ) and the excited state lifetime. We present an analytical description of such a system and show that fluorescence around the onset of saturation is characterized by product of absorption cross section and lifetime. Using this approach we formulate a generalized method for measuring the multiphoton cross section of fluorophores and use it to obtain the absolute three-photon cross-section spectra of tryptophan. We find that the tryptophan three-photon cross section ranges from 0.28 S.I. units (m(6)s(2)photon(-2)) at 870 nm to 20 S.I. units at 740 nm. Further, we show that the product of molecular rate of excitation and de-excitation, denoted as β, serves as a vital contrasting agent for imaging local environment. Our contrast parameter, β, is related to fraction of the population present in the excited state and is independent of the fluorophore concentration. We show that β-imaging can be carried out in a regular two-photon microscope setup through a series of intensity scans. Using enhanced green fluorescent protein (EGFP) fluorescence from the brain slices of Thy-1 EGFP transgenic mice, we show that there is an inherent, concentration independent, variation in contrast across the soma and the dendrite. PMID:27653491

  17. Absolute gain measurement of microstrip antennas under mismatched conditions

    NASA Technical Reports Server (NTRS)

    Lee, R. Q.; Baddour, M. F.

    1988-01-01

    The gain of a single microstrip patch and a two-layer parasitic array is measured using the image method under mismatched conditions. This method produces accurate results, even in the case of low-gain microstrip antennas. The advantages of this method over the gain comparison technique are discussed.

  18. Absolute electron density measurements in the equatorial ionosphere

    NASA Technical Reports Server (NTRS)

    Baker, K. D.; Howlett, L. C.; Rao, N. B.; Ulwick, J. C.; Labelle, J.

    1985-01-01

    Accurate measurement of the electron density profile and its variations is crucial to further progress in understanding the physics of the disturbed equatorial ionosphere. To accomplish this, a plasma frequency probe was included in the payload complement of two rockets flown during the Condor rocket campaign conducted from Peru in March 1983. This paper presents density profiles of the disturbed equatorial ionosphere from a night-time flight in which spread-F conditions were present and from a day-time flight during strong electrojet conditions. Results from both flights are in excellent agreement with simultaneous radar data in that the regions of highly disturbed plasma coincide with the radar signatures. The spread-F rocket penetrated a topside depletion during both the upleg and downleg. The electrojet measurements showed a profile peaking at 1.3 x 10 to the 5th per cu cm at 106 km, with large scale fluctuations having amplitudes of roughly 10 percent seen only in the upward gradient in electron density. This is in agreement with plasma instability theory. It is further shown that simultaneous measurements by fixed-bias Langmuir probes, when normalized at a single point to the altitude profile of electron density, are inadequate to correctly parameterize the observed enhancements and depletions.

  19. Absolute beam energy measurements in e+e- storage rings

    NASA Astrophysics Data System (ADS)

    Placidi, M.

    1997-01-01

    The CERN Large Electron Positron collider (LEP) was dedicated to the measurement of the mass Mz and the width Γz of the Z0 resonance during the LEP1 phase which terminated in September 1995. The Storage Ring operated in Energy Scan mode during the 1993 and 1995 physics runs by choosing the beam energy Ebeam to correspond to a center-of-mass (CM) energy at the interaction points (IPs) ECMpeak±1762 MeV. After a short review of the techniques usually adopted to set and control the beam energy, this paper describes in more detail two methods adopted at LEP for precise beam energy determination that are essential to reduce the contribution to the systematic error on Mz and Γz. The positron beam momentum was initially determined at the 20-GeV injection energy by measuring the speed of a less relativistic proton beam circulating on the same orbit, taking advantage of the unique opportunity to inject two beams into the LEP at short time intervals. The positron energy at the Z0 peak was in this case derived by extrapolation. Once transverse polarization became reproducible, the Resonant Depolarization (RD) technique was implemented at the Z0 operating energies, providing a ⩽2×10-5 instantaneous accuracy. RD Beam Energy Calibration has been adopted during the LEP Energy Scan campaigns as well as in Accelerator Physics runs for accurate measurement of machine parameters.

  20. Absolute radiometric calibration of Als intensity data: effects on accuracy and target classification.

    PubMed

    Kaasalainen, Sanna; Pyysalo, Ulla; Krooks, Anssi; Vain, Ants; Kukko, Antero; Hyyppä, Juha; Kaasalainen, Mikko

    2011-01-01

    Radiometric calibration of airborne laser scanning (ALS) intensity data aims at retrieving a value related to the target scattering properties, which is independent on the instrument or flight parameters. The aim of a calibration procedure is also to be able to compare results from different flights and instruments, but practical applications are sparsely available, and the performance of calibration methods for this purpose needs to be further assessed. We have studied the radiometric calibration with data from three separate flights and two different instruments using external calibration targets. We find that the intensity data from different flights and instruments can be compared to each other only after a radiometric calibration process using separate calibration targets carefully selected for each flight. The calibration is also necessary for target classification purposes, such as separating vegetation from sand using intensity data from different flights. The classification results are meaningful only for calibrated intensity data.

  1. Absolute radiometric calibration of Als intensity data: effects on accuracy and target classification.

    PubMed

    Kaasalainen, Sanna; Pyysalo, Ulla; Krooks, Anssi; Vain, Ants; Kukko, Antero; Hyyppä, Juha; Kaasalainen, Mikko

    2011-01-01

    Radiometric calibration of airborne laser scanning (ALS) intensity data aims at retrieving a value related to the target scattering properties, which is independent on the instrument or flight parameters. The aim of a calibration procedure is also to be able to compare results from different flights and instruments, but practical applications are sparsely available, and the performance of calibration methods for this purpose needs to be further assessed. We have studied the radiometric calibration with data from three separate flights and two different instruments using external calibration targets. We find that the intensity data from different flights and instruments can be compared to each other only after a radiometric calibration process using separate calibration targets carefully selected for each flight. The calibration is also necessary for target classification purposes, such as separating vegetation from sand using intensity data from different flights. The classification results are meaningful only for calibrated intensity data. PMID:22346660

  2. Absolute measurement of F2-laser power at 157 nm

    SciTech Connect

    Kueck, Stefan; Brandt, Friedhelm; Kremling, Hans-Albert; Gottwald, Alexander; Hoehl, Arne; Richter, Mathias

    2006-05-10

    We report a comparison of laser power measurements at the F2-laser wavelength oaf nm made at two facilities of the Physikalisch-Technische Bundesanstalt (PTB), the German national metrology institute. At the PTB laboratory at the electron storage ring BESSY II in Berlin, the scale for laser power was directly traced to a cryogenic radiometer operating at 157 nm, whereas at the PTB laser radiometry facility in Braunschweig the calibration of transfer detectors was performed with a newly developed standard for laser power at 157 nm, which is traceable in several steps to a cryogenic radiometer operating at 633 nm. The comparison was performed under vacuum conditions with laser pulse energies of?10 {mu}J, however with different average powers because different primary standard radiometers were used. The relative deviation for the responsivity of the transfer detector was 4.8% and thus within the combined standard uncertainty.

  3. Quantitative Vapor-phase IR Intensities and DFT Computations to Predict Absolute IR Spectra based on Molecular Structure: I. Alkanes

    SciTech Connect

    Williams, Stephen D.; Johnson, Timothy J.; Sharpe, Steven W.; Yavelak, Veronica; Oats, R. P.; Brauer, Carolyn S.

    2013-11-13

    Recently recorded quantitative IR spectra of a variety of gas-phase alkanes are shown to have integrated intensities in both the C-H stretching and C-H bending regions that depend linearly on the molecular size, i.e. the number of C-H bonds. This result is well predicted from CH4 to C15H32 by DFT computations of IR spectra at the B3LYP/6-31+G(d,p) level of DFT theory. A simple model predicting the absolute IR band intensities of alkanes based only on structural formula is proposed: For the C-H stretching band near 2930 cm-1 this is given by (in km/mol): CH¬_str = (34±3)*CH – (41±60) where CH is number of C-H bonds in the alkane. The linearity is explained in terms of coordinated motion of methylene groups rather than the summed intensities of autonomous -CH2- units. The effect of alkyl chain length on the intensity of a C-H bending mode is explored and interpreted in terms of conformer distribution. The relative intensity contribution of a methyl mode compared to the total C-H stretch intensity is shown to be linear in the number of terminal methyl groups in the alkane, and can be used to predict quantitative spectra a priori based on structure alone.

  4. Assessment of absolute added correlative coding in optical intensity modulation and direct detection channels

    NASA Astrophysics Data System (ADS)

    Dong-Nhat, Nguyen; Elsherif, Mohamed A.; Malekmohammadi, Amin

    2016-06-01

    The performance of absolute added correlative coding (AACC) modulation format with direct detection has been numerically and analytically reported, targeting metro data center interconnects. Hereby, the focus lies on the performance of the bit error rate, noise contributions, spectral efficiency, and chromatic dispersion tolerance. The signal space model of AACC, where the average electrical and optical power expressions are derived for the first time, is also delineated. The proposed modulation format was also compared to other well-known signaling, such as on-off-keying (OOK) and four-level pulse-amplitude modulation, at the same bit rate in a directly modulated vertical-cavity surface-emitting laser-based transmission system. The comparison results show a clear advantage of AACC in achieving longer fiber delivery distance due to the higher dispersion tolerance.

  5. Standardization of xenon-127 and measurement of photon emission intensities.

    PubMed

    Rodrigues, M; Lépy, M-C; Cassette, P; Mougeot, X; Bé, M M

    2014-05-01

    Xenon-127 was standardized by internal gas counting using three proportional counters in a differential arrangement to eliminate edge effects. The detection efficiency of the proportional counters was calculated by considering the cascade of events following the electron capture and associated gamma transitions. Activity per unit volume was measured with 0.7% relative standard uncertainty. Gamma-ray spectrometry was performed and absolute photon emission intensities were derived. This study shows that (127)Xe could be a surrogate for (133)Xe for the calibration of remote radio-xenon monitoring stations.

  6. Dynamic frequency-domain interferometer for absolute distance measurements with high resolution

    SciTech Connect

    Weng, Jidong; Liu, Shenggang; Ma, Heli; Tao, Tianjiong; Wang, Xiang; Liu, Cangli; Tan, Hua

    2014-11-15

    A unique dynamic frequency-domain interferometer for absolute distance measurement has been developed recently. This paper presents the working principle of the new interferometric system, which uses a photonic crystal fiber to transmit the wide-spectrum light beams and a high-speed streak camera or frame camera to record the interference stripes. Preliminary measurements of harmonic vibrations of a speaker, driven by a radio, and the changes in the tip clearance of a rotating gear wheel show that this new type of interferometer has the ability to perform absolute distance measurements both with high time- and distance-resolution.

  7. Measurement of muon intensity by Cerenkov method

    NASA Technical Reports Server (NTRS)

    Liu, Z. H.; Li, G. J.; Bai, G. Z.; Liu, J. G.; Geng, Q. X.; Ling, J.

    1985-01-01

    Optical detection is an important technique in studies and observations of air showers, muons and relevant phenomena. The muon intensity is measured in a proper energy range and to study some problems about Cerenkov radiation of cosmic rays are studied, by a muon-telescope operated with Cerenkov detector. It is found that the measured muon intensity agrees with the integral energy spectrum of cosmic ray muons.

  8. Sounding rocket measurement of the absolute solar EUV flux utilizing a silicon photodiode

    NASA Technical Reports Server (NTRS)

    Ogawa, H. S.; Mcmullin, D.; Judge, D. L.; Canfield, L. R.

    1990-01-01

    A newly developed stable and high quantum efficiency silicon photodiode was used to obtain an accurate measurement of the integrated absolute magnitude of the solar extreme UV photon flux in the spectral region between 50 and 800 A. The adjusted daily 10.7-cm solar radio flux and sunspot number were 168.4 and 121, respectively. The unattenuated absolute value of the solar EUV flux at 1 AU in the specified wavelength region was 6.81 x 10 to the 10th photons/sq cm per s. Based on a nominal probable error of 7 percent for National Institute of Standards and Technology detector efficiency measurements in the 50- to 500-A region (5 percent on longer wavelength measurements between 500 and 1216 A), and based on experimental errors associated with the present rocket instrumentation and analysis, a conservative total error estimate of about 14 percent is assigned to the absolute integral solar flux obtained.

  9. Measurement of absolute optical thickness of mask glass by wavelength-tuning Fourier analysis.

    PubMed

    Kim, Yangjin; Hbino, Kenichi; Sugita, Naohiko; Mitsuishi, Mamoru

    2015-07-01

    Optical thickness is a fundamental characteristic of an optical component. A measurement method combining discrete Fourier-transform (DFT) analysis and a phase-shifting technique gives an appropriate value for the absolute optical thickness of a transparent plate. However, there is a systematic error caused by the nonlinearity of the phase-shifting technique. In this research the absolute optical-thickness distribution of mask blank glass was measured using DFT and wavelength-tuning Fizeau interferometry without using sensitive phase-shifting techniques. The error occurring during the DFT analysis was compensated for by using the unwrapping correlation. The experimental results indicated that the absolute optical thickness of mask glass was measured with an accuracy of 5 nm.

  10. Electrical Noise and the Measurement of Absolute Temperature, Boltzmann's Constant and Avogadro's Number.

    ERIC Educational Resources Information Center

    Ericson, T. J.

    1988-01-01

    Describes an apparatus capable of measuring absolute temperatures of a tungsten filament bulb up to normal running temperature and measuring Botzmann's constant to an accuracy of a few percent. Shows that electrical noise techniques are convenient to demonstrate how the concept of temperature is related to the micro- and macroscopic world. (CW)

  11. Absolute Intensities of γ Rays Emitted in the Decay of 239U

    NASA Astrophysics Data System (ADS)

    Griffin, Henry C.

    2008-08-01

    A source of 239U was produced by the 238U(n,γ)239U reactions and was purified by radiochemistry. Disintegration rates were determined by 4π counting in a liquid scintillation spectrometer, and gamma emission rates were determined by counting liquid samples with well-characterized HPGe spectrometers. The prominent 74.7-keV γ ray was found to occur in 53.9(5)% of the decays, and this value was used to obtain intensities for L and K x-rays and γ rays from 31 to 1102 keV.

  12. Absolutely calibrated, time-resolved measurements of soft x rays using transmission grating spectrometers at the Nike Laser Facility

    NASA Astrophysics Data System (ADS)

    Weaver, J. L.; Feldman, U.; Seely, J. F.; Holland, G.; Serlin, V.; Klapisch, M.; Columbant, D.; Mostovych, A.

    2001-12-01

    Accurate simulation of pellet implosions for direct drive inertial confinement fusion requires benchmarking the codes with experimental data. The Naval Research Laboratory (NRL) has begun to measure the absolute intensity of radiation from laser irradiated targets to provide critical information for the radiatively preheated pellet designs developed by the Nike laser group. Two main diagnostics for this effort are two spectrometers incorporating three detection systems. While both spectrometers use 2500 lines/mm transmission gratings, one instrument is coupled to a soft x-ray streak camera and the other is coupled to both an absolutely calibrated Si photodiode array and a charge coupled device (CCD) camera. Absolute calibration of spectrometer components has been undertaken at the National Synchrotron Light Source at Brookhaven National Laboratories. Currently, the system has been used to measure the spatially integrated soft x-ray flux as a function of target material, laser power, and laser spot size. A comparison between measured and calculated flux for Au and CH targets shows reasonable agreement to one-dimensional modeling for two laser power densities.

  13. Beta decay of the fission product 125Sb and a new complete evaluation of absolute gamma ray transition intensities

    NASA Astrophysics Data System (ADS)

    Rajput, M. U.; Ali, N.; Hussain, S.; Mujahid, S. A.; MacMahon, D.

    2012-04-01

    The radionuclide 125Sb is a long-lived fission product, which decays to 125Te by negative beta emission with a half-life of 1008 day. The beta decay is followed by the emission of several gamma radiations, ranging from low to medium energy, that can suitably be used for high-resolution detector calibrations, decay heat calculations and in many other applications. In this work, the beta decay of 125Sb has been studied in detail. The complete published experimental data of relative gamma ray intensities in the beta decay of the radionuclide 125Sb has been compiled. The consistency analysis was performed and discrepancies found at several gamma ray energies. Evaluation of the discrepant data was carried out using Normalized Residual and RAJEVAL methods. The decay scheme balance was carried out using beta branching ratios, internal conversion coefficients, populating and depopulating gamma transitions to 125Te levels. The work has resulted in the consistent conversion factor equal to 29.59(13) %, and determined a new evaluated set of the absolute gamma ray emission probabilities. The work has also shown 22.99% of the delayed intensity fraction as outgoing from the 58 d isomeric 144 keV energy level and 77.01% of the prompt intensity fraction reaching to the ground state from the other excited states. The results are discussed and compared with previous evaluations. The present work includes additional experimental data sets which were not included in the previous evaluations. A new set of recommended relative and absolute gamma ray emission probabilities is presented.

  14. High precision absolute distance measurement with the fiber femtosecond optical frequency comb

    NASA Astrophysics Data System (ADS)

    Guo, Jiashuai; Wu, Tengfei; Liang, Zhiguo; Wang, Yu; Han, Jibo

    2016-01-01

    The absolute distance measurement was experimentally demonstrated by using the fiber femtosecond optical frequency comb in air. The technique is based on the measurement of cross correlation between reference and measurement optical pulses. This method can achieve accuracy better than the commercial laser interferometer. It is attained sub-micrometer resolution in large scale measurement by using the fiber femtosecond optical frequency comb. It will be benefit for future laser lidar and satellite formation flying mission.

  15. First Absolutely Calibrated Localized Measurements of Ion Velocity in the MST in Locked and Rotating Plasmas

    NASA Astrophysics Data System (ADS)

    Baltzer, M.; Craig, D.; den Hartog, D. J.; Nornberg, M. D.; Munaretto, S.

    2015-11-01

    An Ion Doppler Spectrometer (IDS) is used on MST for high time-resolution passive and active measurements of impurity ion emission. Absolutely calibrated measurements of flow are difficult because the spectrometer records data within 0.3 nm of the C+5 line of interest, and commercial calibration lamps do not produce lines in this narrow range . A novel optical system was designed to absolutely calibrate the IDS. The device uses an UV LED to produce a broad emission curve in the desired region. A Fabry-Perot etalon filters this light, cutting transmittance peaks into the pattern of the LED emission. An optical train of fused silica lenses focuses the light into the IDS with f/4. A holographic diffuser blurs the light cone to increase homogeneity. Using this light source, the absolute Doppler shift of ion emissions can be measured in MST plasmas. In combination with charge exchange recombination spectroscopy, localized ion velocities can now be measured. Previously, a time-averaged measurement along the chord bisecting the poloidal plane was used to calibrate the IDS; the quality of these central chord calibrations can be characterized with our absolute calibration. Calibration errors may also be quantified and minimized by optimizing the curve-fitting process. Preliminary measurements of toroidal velocity in locked and rotating plasmas will be shown. This work has been supported by the US DOE.

  16. Calibration-free absolute frequency response measurement of directly modulated lasers based on additional modulation.

    PubMed

    Zhang, Shangjian; Zou, Xinhai; Wang, Heng; Zhang, Yali; Lu, Rongguo; Liu, Yong

    2015-10-15

    A calibration-free electrical method is proposed for measuring the absolute frequency response of directly modulated semiconductor lasers based on additional modulation. The method achieves the electrical domain measurement of the modulation index of directly modulated lasers without the need for correcting the responsivity fluctuation in the photodetection. Moreover, it doubles measuring frequency range by setting a specific frequency relationship between the direct and additional modulation. Both the absolute and relative frequency response of semiconductor lasers are experimentally measured from the electrical spectrum of the twice-modulated optical signal, and the measured results are compared to those obtained with conventional methods to check the consistency. The proposed method provides calibration-free and accurate measurement for high-speed semiconductor lasers with high-resolution electrical spectrum analysis.

  17. In situ measurement of leaf chlorophyll concentration: analysis of the optical/absolute relationship.

    PubMed

    Parry, Christopher; Blonquist, J Mark; Bugbee, Bruce

    2014-11-01

    In situ optical meters are widely used to estimate leaf chlorophyll concentration, but non-uniform chlorophyll distribution causes optical measurements to vary widely among species for the same chlorophyll concentration. Over 30 studies have sought to quantify the in situ/in vitro (optical/absolute) relationship, but neither chlorophyll extraction nor measurement techniques for in vitro analysis have been consistent among studies. Here we: (1) review standard procedures for measurement of chlorophyll; (2) estimate the error associated with non-standard procedures; and (3) implement the most accurate methods to provide equations for conversion of optical to absolute chlorophyll for 22 species grown in multiple environments. Tests of five Minolta (model SPAD-502) and 25 Opti-Sciences (model CCM-200) meters, manufactured from 1992 to 2013, indicate that differences among replicate models are less than 5%. We thus developed equations for converting between units from these meter types. There was no significant effect of environment on the optical/absolute chlorophyll relationship. We derive the theoretical relationship between optical transmission ratios and absolute chlorophyll concentration and show how non-uniform distribution among species causes a variable, non-linear response. These results link in situ optical measurements with in vitro chlorophyll concentration and provide insight to strategies for radiation capture among diverse species.

  18. Re-creating Gauss's method for non-electrical absolute measurements of magnetic fields and moments

    NASA Astrophysics Data System (ADS)

    Van Baak, D. A.

    2013-10-01

    In 1832, Gauss made the first absolute measurements of magnetic fields and of magnetic moments in experiments that are straightforward and instructive to replicate. We show, using rare-earth permanent magnets and a variation of Gauss's technique, that the horizontal component of the ambient geomagnetic field, as well as the size of the magnetic moments of such magnets, can be found. The method shows the connection between the SI and cgs emu unit systems for these quantities and permits an absolute realization of the Ampere with considerable precision.

  19. Absolute measurement by satellite altimetry of dynamic topography of the Pacific Ocean

    NASA Technical Reports Server (NTRS)

    Tai, C.-K.; Wunsch, C.

    1983-01-01

    The three-month Seasat mission has shown that altimetry is capable of providing global observations of oceanic variability. It is shown that data from this short, suboptimum mission are also adequate for a determination of the absolute sea-surface topography of the ocean on large scales. An absolute determination of the subtropical gyre of the North Pacific Ocean is obtained. This is believed to be the first direct measurement showing the existence of such a feature that does not depend on conventional hydrography and a series of assumptions.

  20. Measurement of the absolute differential cross section for np elastic scattering at 194 MeV

    SciTech Connect

    Sarsour, M.; Peterson, T.; Planinic, M.; Vigdor, S. E.; Allgower, C.; Hossbach, T.; Jacobs, W. W.; Klyachko, A. V.; Rinckel, T.; Stephenson, E. J.; Wissink, S. W.; Zhou, Y.; Bergenwall, B.; Blomgren, J.; Johansson, C.; Klug, J.; Nadel-Turonski, P.; Nilsson, L.; Olsson, N.; Pomp, S.

    2006-10-15

    A tagged medium-energy neutron beam was used in a precise measurement of the absolute differential cross section for np backscattering. The results resolve significant discrepancies within the np database concerning the angular dependence in this regime. The experiment has determined the absolute normalization with {+-}1.5% uncertainty, suitable to verify constraints of supposedly comparable precision that arise from the rest of the database in partial wave analyses. The analysis procedures, especially those associated with the evaluation of systematic errors in the experiment, are described in detail so that systematic uncertainties may be included in a reasonable way in subsequent partial wave analysis fits incorporating the present results.

  1. A measure of intensity of parental punishment.

    PubMed

    Gordon, D A; Jones, R H; Nowicki, S

    1979-10-01

    To test the possibilities that antecedents and consequents of certain levels of intensity of punishment may have far-reaching effects on behavior, a self-report measure of parental intensity of punishment was developed. Consisting of 33 different situations to which parents react, scores from the instrument were found to be reliable over time. Further construct validity was demonstrated with a variety of predicted relationships between punishment intensity and parent and child characteristics. Five samples of subjects were used with over 400 families, high intensity of punishment scores were found to be related to mothers' lack of warmth and to her intrusiveness when playing with her child; children's maladjusted behavior; aggression and impulsivity in boys; withdrawal and inhibition in girls, and uncooperativeness. Inconsistency of parental punishment also was associated with maladjustment. Results were discussed in terms of Rotter's social learning theory.

  2. Demonstrating the Error Budget for the Climate Absolute Radiance and Refractivity Observatory Through Solar Irradiance Measurements

    NASA Technical Reports Server (NTRS)

    Thome, Kurtis; McCorkel, Joel; McAndrew, Brendan

    2016-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe highaccuracy, long-term climate change trends and to use decadal change observations as a method to determine the accuracy of climate change. A CLARREO objective is to improve the accuracy of SI-traceable, absolute calibration at infrared and reflected solar wavelengths to reach on-orbit accuracies required to allow climate change observations to survive data gaps and observe climate change at the limit of natural variability. Such an effort will also demonstrate National Institute of Standards and Technology (NIST) approaches for use in future spaceborne instruments. The current work describes the results of laboratory and field measurements with the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. SOLARIS allows testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. Results of laboratory calibration measurements are provided to demonstrate key assumptions about instrument behavior that are needed to achieve CLARREO's climate measurement requirements. Absolute radiometric response is determined using laser-based calibration sources and applied to direct solar views for comparison with accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

  3. Demonstrating the error budget for the Climate Absolute Radiance and Refractivity Observatory through solar irradiance measurements

    NASA Astrophysics Data System (ADS)

    Thome, Kurtis; McCorkel, Joel; McAndrew, Brendan

    2015-09-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe highaccuracy, long-term climate change trends and to use decadal change observations as a method to determine the accuracy of climate change. A CLARREO objective is to improve the accuracy of SI-traceable, absolute calibration at infrared and reflected solar wavelengths to reach on-orbit accuracies required to allow climate change observations to survive data gaps and observe climate change at the limit of natural variability. Such an effort will also demonstrate National Institute of Standards and Technology (NIST) approaches for use in future spaceborne instruments. The current work describes the results of laboratory and field measurements with the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. SOLARIS allows testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a testbed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. Results of laboratory calibration measurements are provided to demonstrate key assumptions about instrument behavior that are needed to achieve CLARREO's climate measurement requirements. Absolute radiometric response is determined using laser-based calibration sources and applied to direct solar views for comparison with accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

  4. Fully distributed absolute blood flow velocity measurement for middle cerebral arteries using Doppler optical coherence tomography

    PubMed Central

    Qi, Li; Zhu, Jiang; Hancock, Aneeka M.; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D.; Chen, Zhongping

    2016-01-01

    Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it is related to vessel geometry. In this paper, we present a volumetric vessel reconstruction approach that is capable of measuring the absolute BFV distributed along the entire middle cerebral artery (MCA) within a large field-of-view. The Doppler angle at each point of the MCA, representing the vessel geometry, is derived analytically by localizing the artery from pure DOCT images through vessel segmentation and skeletonization. Our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches. Experiments on rodents using swept-source optical coherence tomography showed that our approach was able to reveal the consequences of permanent MCA occlusion with absolute BFV measurement. PMID:26977365

  5. Absolute sensitivity calibration of vacuum and extreme ultraviolet spectrometer systems and Z{sub eff} measurement based on bremsstrahlung continuum in HL-2A tokamak

    SciTech Connect

    Zhou Hangyu; Cui Zhengying; Fu Bingzhong; Sun Ping; Gao Yadong; Xu Yuan; Lu Ping; Yang Qingwei; Duan Xuru; Morita, Shigeru; Goto, Motoshi; Dong Chunfeng

    2012-10-15

    A grazing-incidence flat-field extreme ultraviolet (EUV) spectrometer has been newly developed in HL-2A tokamak. Typical spectral lines are observed from intrinsic impurities of carbon, oxygen, iron, and extrinsic impurity of helium in the wavelength range of 20 A-500 A. Bremsstrahlung continuum is measured at different electron densities of HL-2A discharges to calibrate absolute sensitivity of the EUV spectrometer system and to measure effective ionic charge, Z{sub eff}. The sensitivity of a vacuum ultraviolet (VUV) spectrometer system is also absolutely calibrated in overlapped wavelength range of 300 A-500 A by comparing the intensity between VUV and EUV line emissions.

  6. Measurement of absolute CO number densities in CH3F/O2 plasmas by optical emission self-actinometry

    NASA Astrophysics Data System (ADS)

    Karakas, Erdinc; Kaler, Sanbir; Lou, Qiaowei; Donnelly, Vincent M.; Economou, Demetre J.

    2014-02-01

    CH3F/O2 inductively coupled plasmas at 10 mTorr were investigated using optical emission spectroscopy. A ‘self-actinometry’ method was developed to measure the absolute number density of CO that formed in reactions following dissociation of CH3F and O2 in the plasma. In this method, small amounts of CO were added to the plasma, leading to small increases in the CO emission intensity. By carefully accounting for small perturbations to the plasma electron density and/or electron energy distribution, and by showing that very little of the CO added to the plasma was decomposed by electron impact or other reactions, it was possible to derive absolute number densities for the CO content of the plasma. With equal fractions (0.50) of CH3F and O2 in the feed gas, the CO mole fraction as a function of plasma power saturated at a value of 0.20-0.25. As O2 in the feed gas was varied at a constant power of 100 W, the CO mole fraction went through a maximum of about 0.25 near an O2 feed gas fraction of 0.5. The relative CO number densities determined by ‘standard’ actinometry followed the same functional dependence as the absolute mole fractions determined by self-actinometry, aided by the fact that electron temperature did not change appreciably with power or feed gas composition.

  7. Introducing an Absolute Cavity Pyrgeometer for Improving the Atmospheric Longwave Irradiance Measurement (Presentation)

    SciTech Connect

    Reda, I.; Hansen, L.; Zeng, J.

    2012-08-01

    Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer (ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined by lowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the WISG. A total of 408 readings was collected over three different clear nights. The calculated irradiance measured by the ACP was 1.5 W/m2 lower than that measured by the two pyrgeometers that are traceable to WISG. Further development and characterization of the ACP might contribute to the effort of improving the uncertainty and traceability of WISG to SI.

  8. Hilbertian sine as an absolute measure of Bayesian inference in ISR, homeland security, medicine, and defense

    NASA Astrophysics Data System (ADS)

    Jannson, Tomasz; Wang, Wenjian; Hodelin, Juan; Forrester, Thomas; Romanov, Volodymyr; Kostrzewski, Andrew

    2016-05-01

    In this paper, Bayesian Binary Sensing (BBS) is discussed as an effective tool for Bayesian Inference (BI) evaluation in interdisciplinary areas such as ISR (and, C3I), Homeland Security, QC, medicine, defense, and many others. In particular, Hilbertian Sine (HS) as an absolute measure of BI, is introduced, while avoiding relativity of decision threshold identification, as in the case of traditional measures of BI, related to false positives and false negatives.

  9. Absolute spectral irradiance measurements of lightning from 375 to 880 nm

    NASA Technical Reports Server (NTRS)

    Orville, R. E.; Henderson, R. W.

    1984-01-01

    The time-integrated emissions from cloud-to-ground lightning have been recorded in the 375-880 nm region, using a spectrometer-detector and multichannel analyzer system capable of absolute spectral irradiance measurements. A schematic drawing of the detector-analyzer system is presented, and the experimental setup is described. A total of ten flashes containing 46 individual strikes were recorded and compared to recordings of 500 flashes from 1981. The average spectral irradiance from 375 to 695 nm for flashes at about 15 km was 3.5 x 10 to the -5th J/sq m per stroke with a standard deviation of 2.0 x 10 to the -5th and a range from 0.7 x 10 to the 0.7-6.8 x 10 to the -5th J/sq m per stroke. The average stroke spectra irradiance from 650 to 880 nm for the same strokes was 1.2 x 10 to the -5th, with a standard deviation of 0.7 x 10 to the -5th and a range from 0.5 to 3.2 x 10 to the -5th J/sq m per stroke. A summary table of spectral irradiance values in 50 nm increment is presented. Analysis of the spectral emission data show that unresolved neutral hydrogen lines (NI) at 744.2 nm were more intense than H-alpha emission at 656.3 nm. The strong emission of a flash with a continuing current was identified as cyanogen (CN) emission.

  10. Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

    SciTech Connect

    Mackinnon, A; Casey, D; Frenje, J A; Johnson, M G; Seguin, F H; Li, C K; Petrasso, R D; Glebov, V Y; Katz, J; Knauer, J; Meyerhofer, D; Sangster, T; Bionta, R; Bleuel, D; Hachett, S P; Hartouni, E; Lepape, S; Mckernan, M; Moran, M; Yeamans, C

    2012-05-03

    A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  11. Absolute frequency measurement at 10-16 level based on the international atomic time

    NASA Astrophysics Data System (ADS)

    Hachisu, H.; Fujieda, M.; Kumagai, M.; Ido, T.

    2016-06-01

    Referring to International Atomic Time (TAI), we measured the absolute frequency of the 87Sr lattice clock with its uncertainty of 1.1 x 10-15. Unless an optical clock is continuously operated for the five days of the TAI grid, it is required to evaluate dead time uncertainty in order to use the available five-day average of the local frequency reference. We homogeneously distributed intermittent measurements over the five-day grid of TAI, by which the dead time uncertainty was reduced to low 10-16 level. Three campaigns of the five (or four)-day consecutive measurements have resulted in the absolute frequency of the 87Sr clock transition of 429 228 004 229 872.85 (47) Hz, where the systematic uncertainty of the 87Sr optical frequency standard amounts to 8.6 x 10-17.

  12. Precise measurements of the absolute γ-ray emission probabilities of (223)Ra and decay progeny in equilibrium.

    PubMed

    Collins, S M; Pearce, A K; Regan, P H; Keightley, J D

    2015-08-01

    Precise measurements of the absolute γ-ray emission probabilities have been made of radiochemically pure solutions of (223)Ra in equilibrium with its decay progeny, which had been previously standardised by 4π(liquid scintillation)-γ digital coincidence counting techniques. Two high-purity germanium γ-ray spectrometers were used which had been accurately calibrated using a suite of primary and secondary radioactive standards. Comparison of the activity concentration determined by the primary technique against γ-ray spectrometry measurements using the nuclear data evaluations of the Decay Data Evaluation Project exhibited a range of ~18% in the most intense γ-ray emissions (>1% probability) of the (223)Ra decay series. Absolute γ-ray emission probabilities and standard uncertainties have been determined for the decay of (223)Ra, (219)Rn, (215)Po, (211)Pb, (211)Bi and (207)Tl in equilibrium. The standard uncertainties of the measured γ-ray emission probabilities quoted in this work show a significant improvement over previously reported γ-ray emission probabilities. Correlation coefficients for pairs of the measured γ-ray emission probabilities from the decays of the radionuclides (223)Ra, (219)Rn and (211)Pb have been determined and are presented. The α-transition probabilities of the (223)Ra have been deduced from P(γ+ce) balance using the γ-ray emission probabilities determined in this work with some agreement observed with the published experimental values of the α-emission probabilities.

  13. Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

    SciTech Connect

    Reda, I.; Stoffel, T.

    2012-03-01

    Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer (ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined by lowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the WISG.

  14. Temperature-dependent Absolute Refractive Index Measurements of Synthetic Fused Silica

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.; Frey, Bradley J.

    2006-01-01

    Using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have measured the absolute refractive index of five specimens taken from a very large boule of Corning 7980 fused silica from temperatures ranging from 30 to 310 K at wavelengths from 0.4 to 2.6 microns with an absolute uncertainty of plus or minus 1 x 10 (exp -5). Statistical variations in derived values of the thermo-optic coefficient (dn/dT) are at the plus or minus 2 x 10 (exp -8)/K level. Graphical and tabulated data for absolute refractive index, dispersion, and thermo-optic coefficient are presented for selected wavelengths and temperatures along with estimates of uncertainty in index. Coefficients for temperature-dependent Sellmeier fits of measured refractive index are also presented to allow accurate interpolation of index to other wavelengths and temperatures. We compare our results to those from an independent investigation (which used an interferometric technique for measuring index changes as a function of temperature) whose samples were prepared from the same slugs of material from which our prisms were prepared in support of the Kepler mission. We also compare our results with sparse cryogenic index data from measurements of this material from the literature.

  15. Thorough subcells diagnosis in a multi-junction solar cell via absolute electroluminescence-efficiency measurements

    PubMed Central

    Chen, Shaoqiang; Zhu, Lin; Yoshita, Masahiro; Mochizuki, Toshimitsu; Kim, Changsu; Akiyama, Hidefumi; Imaizumi, Mitsuru; Kanemitsu, Yoshihiko

    2015-01-01

    World-wide studies on multi-junction (tandem) solar cells have led to record-breaking improvements in conversion efficiencies year after year. To obtain detailed and proper feedback for solar-cell design and fabrication, it is necessary to establish standard methods for diagnosing subcells in fabricated tandem devices. Here, we propose a potential standard method to quantify the detailed subcell properties of multi-junction solar cells based on absolute measurements of electroluminescence (EL) external quantum efficiency in addition to the conventional solar-cell external-quantum-efficiency measurements. We demonstrate that the absolute-EL-quantum-efficiency measurements provide I–V relations of individual subcells without the need for referencing measured I–V data, which is in stark contrast to previous works. Moreover, our measurements quantify the absolute rates of junction loss, non-radiative loss, radiative loss, and luminescence coupling in the subcells, which constitute the “balance sheets” of tandem solar cells. PMID:25592484

  16. First measurements of the absolute neutron spectrum using the Magnetic Recoil Spectrometer (MRS) at the NIF

    NASA Astrophysics Data System (ADS)

    Frenje, J.; Casey, D.; Li, C.; Seguin, F.; Petrasso, R.; Bionta, R.; Cerjan, C.; Eckart, M.; Haan, S.; Hatchett, S.; Khater, H.; Landen, O.; MacKinnon, A.; Moran, M.; Rygg, J.; Kilkenny, J.; Glebov, V.; Sangster, T.; Meyerhofer, D.; Magoon, J.; Fletcher, K.; Leeper, R.

    2010-11-01

    Proper assembly of capsule mass, as manifested through evolution of fuel areal density (ρR), is fundamentally important for achieving hot-spot ignition planned at the National Ignition Facility (NIF). Experimental information about ρR and ρR asymmetries, Ti and yield is therefore essential for understanding how this assembly occurs. To obtain this information, a neutron spectrometer, called the Magnetic-Recoil Spectrometer (MRS) has been implemented on the NIF. Its primary objective is to measure the absolute neutron spectrum in the range 5 to 30 MeV, from which ρR, Ti and yield can be directly inferred for both low-yield tritium-hydrogen-deuterium (THD) and high-yield DT implosions. In this talk, the results from the first measurements of the absolute neutron spectrum produced in exploding pusher and THD implosions will be presented. This work was supported in part by the U.S. DOE, LLNL and LLE.

  17. Precise Measurement of the Absolute Yield of Fluorescence Photons in Atmospheric Gases

    SciTech Connect

    Ave, M.; Bohacova, M.; Daumiller, K.; Di Carlo, P.; Di Giulio, C.; Luis, P.Facal San; Gonzales, D.; Hojvat, C.; Horandel, J.R.; Hrabovsky, M.; Iarlori, M.; /INFN, Aquila /Karlsruhe, Inst. Technol.

    2011-01-01

    We have performed a measurement of the absolute yield of fluorescence photons at the Fermilab Test Beam. A systematic uncertainty at 5% level was achieved by the use of Cherenkov radiation as a reference calibration light source. A cross-check was performed by an independent calibration using a laser light source. A significant improvement on the energy scale uncertainty of Ultra-High Energy Cosmic Rays is expected.

  18. Development of explicit diffraction corrections for absolute measurements of acoustic nonlinearity parameters in the quasilinear regime.

    PubMed

    Jeong, Hyunjo; Zhang, Shuzeng; Cho, Sungjong; Li, Xiongbing

    2016-08-01

    In absolute measurements of acoustic nonlinearity parameters, amplitudes of harmonics must be corrected for diffraction effects. In this study, we develop explicit multi-Gaussian beam (MGB) model-based diffraction corrections for the first three harmonics in weakly nonlinear, axisymmetric sound beams. The effects of making diffraction corrections on nonlinearity parameter estimation are investigated by defining "total diffraction correction (TDC)". The results demonstrate that TDC cannot be neglected even for harmonic generation experiments in the nearfield region. PMID:27186964

  19. Absolute band intensities in the nu19/nu23 (530 cm(-1)) and nu7 (777 cm(-1)) bands of acetone ((CH3)2CO) from 232 to 295 K

    NASA Technical Reports Server (NTRS)

    Wang, W. F.; Stevenson, A.; Reuter, D. C.; Sirota, J. M.

    2000-01-01

    Absolute band intensities of acetone ((CH3)2CO) in the nu19/nu23 and nu7 band systems near 530 and 777 cm(-1), respectively, were measured at temperatures of 232, 262 and 295 K, using a Fourier transform infrared (FTIR) spectrometer. No evident temperature dependence for the band intensities was observed. The dipole moments and the fundamental band intensities were derived in the harmonic oscillator approximation. The results are useful for the spectroscopic retrieval of acetone concentrations in the upper atmosphere.

  20. Absolute optical extinction measurements of single nano-objects by spatial modulation spectroscopy using a white lamp.

    PubMed

    Billaud, Pierre; Marhaba, Salem; Grillet, Nadia; Cottancin, Emmanuel; Bonnet, Christophe; Lermé, Jean; Vialle, Jean-Louis; Broyer, Michel; Pellarin, Michel

    2010-04-01

    This article describes a high sensitivity spectrophotometer designed to detect the overall extinction of light by a single nanoparticle (NP) in the 10(-4)-10(-5) relative range, using a transmission measurement configuration. We focus here on the simple and low cost scheme where a white lamp is used as a light source, permitting easy and broadband extinction measurements (300-900 nm). Using a microscope, in a confocal geometry, an increased sensitivity is reached thanks to a modulation of the NP position under the light spot combined with lock-in detection. Moreover, it is shown that this technique gives access to the absolute extinction cross-sections of the single NP provided that the incident electromagnetic field distribution experienced by the NP is accurately characterized. In this respect, an experimental procedure to characterize the light spot profile in the focal plane, using a reference NP as a probe, is also laid out. The validity of this approach is discussed and confirmed by comparing experimental intensity distributions to theoretical calculations taking into account the vector character of the tightly focused beam. The calibration procedure permitting to obtain the absolute extinction cross-section of the probed NP is then fully described. Finally, the force of the present technique is illustrated through selected examples concerning spherical and slightly elongated gold and silver NPs. Absolute extinction measurements are found to be in good consistency with the NP size and shape independently obtained from transmission electron microscopy, showing that spatial modulation spectroscopy is a powerful tool to get an optical fingerprint of the NP. PMID:20441319

  1. Absolute reliability of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer.

    PubMed

    Hirano, Masahiro; Katoh, Munenori

    2015-07-01

    [Purpose] The aim of this study was to verify the absolute reliability of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer (HHD). [Subjects and Methods] The subjects were 33 healthy college students. The measurements were made three times with the HHD fixed using a belt (BFHHD) or with the examiner's hand (conventional method; HFHHD). The absolute reliability of measurements was verified using Bland-Altman analysis, both in the all subjects group and a group of subjects showing measurements less than a fixed limit of 30 kgf. [Results] In the <30 kgf group, a systematic bias was not observed, and BFHHD values were greater than HFHHD values. BFHHD values in the all subjects group showed a systematic bias; the 3rd measurement value was less than the maximum value obtained during the 1st and 2nd measurements. [Conclusion] For obtaining an acceptable value during clinical measurements of horizontal adductor muscle strength, single measurements obtained using an HFHHD in the case of a <30 kgf group and the maximum value of two measurements obtained using a BFHHD are reliable. PMID:26311938

  2. A New Measurement of the Absolute Spectral Reflectance of the Moon

    NASA Technical Reports Server (NTRS)

    Lawrence, S. J.; Lau, E.; Steutel, D.; Stopar, J. D.; Wilcox, B. B.; Lucey, P. G.

    2003-01-01

    The spectral reflectance of the Moon is an important property for studies of lunar geology, quantitative physical modeling of the moon, and in-flight calibration of spacecraft sensors. Previous studies have claimed that telescopic absolute reflectance values for the Moon are greater than laboratory reflectance measurements by a factor of two. In order to confirm these results, we performed ground-based observations of the lunar surface using a visible/near-infrared spectroradiometer and compared the measured lunar surface radiance to solar radiance corrected for atmospheric scattering and absorption. These data were compared to previously obtained laboratory reflectance measurements from Apollo soil samples.

  3. Absolute measurement of electron-cloud density in a positively charged particle beam.

    PubMed

    Kireeff Covo, Michel; Molvik, Arthur W; Friedman, Alex; Vay, Jean-Luc; Seidl, Peter A; Logan, Grant; Baca, David; Vujic, Jasmina L

    2006-08-01

    Clouds of stray electrons are ubiquitous in particle accelerators and frequently limit the performance of storage rings. Earlier measurements of electron energy distribution and flux to the walls provided only a relative electron-cloud density. We have measured electron accumulation using ions expelled by the beam. The ion energy distribution maps the depressed beam potential and gives the dynamic cloud density. Clearing electrode current reveals the static background cloud density, allowing the first absolute measurement of the time-dependent electron-cloud density during the beam pulse.

  4. Modelling and measurement of the absolute level of power radiated by antenna integrated THz UTC photodiodes.

    PubMed

    Natrella, Michele; Liu, Chin-Pang; Graham, Chris; van Dijk, Frederic; Liu, Huiyun; Renaud, Cyril C; Seeds, Alwyn J

    2016-05-30

    We determine the output impedance of uni-travelling carrier (UTC) photodiodes at frequencies up to 400 GHz by performing, for the first time, 3D full-wave modelling of detailed UTC photodiode structures. In addition, we demonstrate the importance of the UTC impedance evaluation, by using it in the prediction of the absolute power radiated by an antenna integrated UTC, over a broad frequency range and confirming the predictions by experimental measurements up to 185 GHz. This is done by means of 3D full-wave modelling and is only possible since the source (UTC) to antenna impedance match is properly taken into account. We also show that, when the UTC-to-antenna coupling efficiency is modelled using the classical junction-capacitance/series-resistance concept, calculated and measured levels of absolute radiated power are in substantial disagreement, and the maximum radiated power is overestimated by a factor of almost 7 dB. The ability to calculate the absolute emitted power correctly enables the radiated power to be maximised through optimisation of the UTC-to-antenna impedance match.

  5. Modelling and measurement of the absolute level of power radiated by antenna integrated THz UTC photodiodes.

    PubMed

    Natrella, Michele; Liu, Chin-Pang; Graham, Chris; van Dijk, Frederic; Liu, Huiyun; Renaud, Cyril C; Seeds, Alwyn J

    2016-05-30

    We determine the output impedance of uni-travelling carrier (UTC) photodiodes at frequencies up to 400 GHz by performing, for the first time, 3D full-wave modelling of detailed UTC photodiode structures. In addition, we demonstrate the importance of the UTC impedance evaluation, by using it in the prediction of the absolute power radiated by an antenna integrated UTC, over a broad frequency range and confirming the predictions by experimental measurements up to 185 GHz. This is done by means of 3D full-wave modelling and is only possible since the source (UTC) to antenna impedance match is properly taken into account. We also show that, when the UTC-to-antenna coupling efficiency is modelled using the classical junction-capacitance/series-resistance concept, calculated and measured levels of absolute radiated power are in substantial disagreement, and the maximum radiated power is overestimated by a factor of almost 7 dB. The ability to calculate the absolute emitted power correctly enables the radiated power to be maximised through optimisation of the UTC-to-antenna impedance match. PMID:27410104

  6. Experimental feasibility of the airborne measurement of absolute oil fluorescence spectral conversion efficiency

    NASA Technical Reports Server (NTRS)

    Hoge, F. E.; Swift, R. N.

    1983-01-01

    Airborne lidar oil spill experiments carried out to determine the practicability of the AOFSCE (absolute oil fluorescence spectral conversion efficiency) computational model are described. The results reveal that the model is suitable over a considerable range of oil film thicknesses provided the fluorescence efficiency of the oil does not approach the minimum detection sensitivity limitations of the lidar system. Separate airborne lidar experiments to demonstrate measurement of the water column Raman conversion efficiency are also conducted to ascertain the ultimate feasibility of converting such relative oil fluorescence to absolute values. Whereas the AOFSCE model is seen as highly promising, further airborne water column Raman conversion efficiency experiments with improved temporal or depth-resolved waveform calibration and software deconvolution techniques are thought necessary for a final determination of suitability.

  7. Absolute Rovibrational Intensities for the Chi(sup 1)Sigma(sup +) v=3 <-- 0 Band of (12)C(16)O Obtained with Kitt Peak and BOMEM FTS Instruments

    NASA Technical Reports Server (NTRS)

    Chackerian, Charles, Jr.; Kshirsagar, R. J.; Giver, L. P.; Brown, L. R.; Condon, Estelle P. (Technical Monitor)

    1999-01-01

    This work was initiated to compare absolute line intensities retrieved with the Kitt Peak FTS (Fourier Transform Spectrometer) and Ames BOMEM FTS. Since thermal contaminations can be a problem using the BOMEM instrument if proper precautions are not taken it was thought that measurements done at 6300 per cm would more easily result in satisfactory intercomparisons. Very recent measurements of the CO 3 <-- 0 band fine intensities confirms results reported here that the intensities listed in HITRAN (High Resolution Molecular Absorption Database) for this band are on the order of six to seven percent too low. All of the infrared intensities in the current HITRAN tabulation are based on the electric dipole moment function reported fifteen years ago. The latter in turn was partly based on intensities for the 3 <-- 0 band reported thirty years ago. We have, therefore, redetermined the electric dipole moment function of ground electronic state CO.

  8. Absolute X-ray emission cross section measurements of Fe K transitions

    NASA Astrophysics Data System (ADS)

    Hell, Natalie; Brown, Gregory V.; Beiersdorfer, Peter; Boyce, Kevin R.; Grinberg, Victoria; Kelley, Richard L.; Kilbourne, Caroline; Leutenegger, Maurice A.; Porter, Frederick Scott; Wilms, Jörn

    2016-06-01

    We have measured the absolute X-ray emission cross sections of K-shell transitions in highly charged L- and K-shell Fe ions using the LLNL EBIT-I electron beam ion trap and the NASA GSFC EBIT Calorimeter Spectrometer (ECS). The cross sections are determined by using the ECS to simultaneously record the spectrum of the bound-bound K-shell transitions and the emission from radiative recombination from trapped Fe ions. The measured spectrum is then brought to an absolute scale by normalizing the measured flux in the radiative recombination features to their theoretical cross sections, which are well known. Once the spectrum is brought to an absolute scale, the cross sections of the K-shell transitions are determined. These measurements are made possible by the ECS, which consists of a 32 channel array, with 14 channels optimized for detecting high energy photons (hν > 10 keV) and 18 channels optimized for detecting low energy photons (hν < 10 keV). The ECS has a large collection area, relatively high energy resolution, and a large bandpass; all properties necessary for this measurement technique to be successful. These data will be used to benchmark cross sections in the atomic reference data bases underlying the plasma modeling codes used to analyze astrophysical spectra, especially those measured by the Soft X-ray Spectrometer calorimeter instrument recently launched on the Hitomi X-ray Observatory.This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344, and supported by NASA grants to LLNL and NASA/GSFC and by ESA under contract No. 4000114313/15/NL/CB.

  9. Design and implementation of a vacuum compatible laser-basedsub-nm resolution absolute distance measurement gauge

    SciTech Connect

    Naulleau, Patrick P.; Denham, Paul E.; Rekawa, Senajith

    2004-02-16

    We describe the design and implementation of a vacuum compatible laser-based absolute distance measurement gauge with sub-nm resolution. The present system is compatible with operation in the 10{sup -8} Torr range and with some minor modifications could be used in the 10{sup -9} Torr range. The system is based on glancing incidence reflection and dual segmented diode detection. The system has been implemented as a focus sensor for extreme ultraviolet interferometry and microlithography experiments at Lawrence Berkeley National Laboratory's Advanced Light Source synchrotron radiation facility and 1{sigma} operational measurement noise floor of 0.26 nm has been demonstrated.

  10. Measurement of the absolute cross section for multiphoton ionization of atomic hydrogen at 248 nm

    SciTech Connect

    Kyrala, G.A.; Nichols, T.D.

    1990-01-01

    We present measurements of the absolute rates for multiphoton ionization of the ground state from atomic hydrogen by a linearly polarized, subpicosecond KrF laser pulse at a wavelength of 248 nm. A laser crossed atomic beam technique is used. The irradiance was varied from 3{times}10{sup 12} w/cm{sup 2} to 2{times}10{sup 14} w/cm{sup 2} and three above threshold ionization peaks were observed. The measured rate for total electron production is less than predicted by the numerical and perturbation calculations, but significantly higher than calculated by the Reiss and Keldysh methods. 21 refs., 7 figs.

  11. Measurement of the absolute hohlraum wall albedo under ignition foot drive conditions

    SciTech Connect

    Suter, L J; Wallace, R J; Hammel, B A; Weber, F A; Landen, O L; Campbell, K M; DeWald, E L; Glenzer, S H; Rosen, M D; Jones, O S; Turner, R E; Kauffmann, R L; Hammer, J H

    2003-11-25

    We present the first measurements of the absolute albedos of hohlraums made from gold or from high-Z mixtures. The measurements are performed over the range of radiation temperatures (70-100 eV) expected during the foot of an indirect-drive temporally-shaped ignition laser pulse, where accurate knowledge of the wall albedo (i.e. soft x-ray wall re-emission) is most critical for determining capsule radiation symmetry. We find that the gold albedo agrees well with calculations using the super transition array opacity model, potentially providing additional margin for ICF ignition.

  12. Measurement of the Absolute Hohlraum Wall Albedo Under Ignition Foot Drive Condition

    SciTech Connect

    Jones, O S; Glenzer, S H; Suter, L J; Turner, R E; Campbell, K M; Dewald, E L; Hammel, B A; Kauffman, R L; Landen, O L; Rosen, M D; Wallace, R J; Weber, F A

    2003-08-26

    We present the first measurements of the absolute albedos of hohlraums made from gold or from high-Z mixtures. The measurements are performed over the range of radiation temperatures (70-100 eV) expected during the foot of an indirect-drive temporally-shaped ignition laser pulse, where accurate knowledge of the wall albedo (i.e. soft x-ray wall re-emission) is most critical for determining capsule radiation symmetry. We find that the gold albedo agrees well with calculations using the super transition array opacity model, potentially providing additional margin for ICF ignition.

  13. Measurement of the speed-of-light perturbation of free-fall absolute gravimeters

    NASA Astrophysics Data System (ADS)

    Rothleitner, Ch; Niebauer, T. M.; Francis, O.

    2014-06-01

    We report on a direct measurement of the relativistic Doppler shift with a commercial free-fall absolute gravimeter of the type FG5X. The observed Doppler shift, which is commonly called speed-of-light perturbation, can be well described by the relativistic Doppler formula, where the constant object velocity is replaced by a time-dependent velocity with constant acceleration. The observed speed-of-light perturbation stands in contrast to other publications, which predict a higher frequency shift. It has been measured with a relative uncertainty of 1.1 × 10-3.

  14. Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

    NASA Technical Reports Server (NTRS)

    Kubalak, David; Hadjimichael, Theodore; Ohl, Raymond; Slotwinski, Anthony; Telfer, Randal; Hayden, Joseph

    2012-01-01

    Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a

  15. An ultrasonic system for measurement of absolute myocardial thickness using a single transducer.

    PubMed

    Pitsillides, K F; Longhurst, J C

    1995-03-01

    We have developed an ultrasonic instrument that can measure absolute regional myocardial wall motion throughout the cardiac cycle using a single epicardial piezoelectric transducer. The methods in place currently that utilize ultrasound to measure myocardial wall thickness are the transit-time sonomicrometer (TTS) and, more recently, the Doppler echo displacement method. Both methods have inherent disadvantages. To address the need for an instrument that can measure absolute dimensions of myocardial wall at any depth, an ultrasonic single-crystal sonomicrometer (SCS) system was developed. This system can identify and track the boundary of the endocardial muscle-blood interface. With this instrument, it is possible to obtain, from a single epicardial transducer, measurement of myocardial wall motion that is calibrated in absolute dimensional units. The operating principles of the proposed myocardial dimension measurement system are as follows. A short duration ultrasonic burst having a frequency of 10 MHz is transmitted from the piezoelectric transducer. Reflected echoes are sampled at two distinct time intervals to generate reference and interface sample volumes. During steady state, the two sample volumes are adjusted so that the reference volume remains entirely within the myocardium, whereas half of the interface sampled volume is located within the myocardium. After amplification and filtering, the true root mean square values of both signals are compared and an error signal is generated. A closed-loop circuit uses the integrated error signal to continuously adjust the position of the two sample volumes. We have compared our system in vitro against a known signal and in vivo against the two-crystal TTS system during control, suppression (ischemia), and enhancement (isoproterenol) of myocardial function. Results were obtained in vitro for accuracy (> 99%), signal linearity (r = 0.99), and frequency response to heart rates > 450 beats/min, and in vivo data were

  16. FBCT fast intensity measurement using TRIC cards

    NASA Astrophysics Data System (ADS)

    Allica, J. C.; Andersen, M.; Belohrad, D.; Jensen, L.; Lenardon, F.; SØby, L.

    2015-04-01

    At the CERN PS complex, precise fast intensity measurements are very important in order to optimize the transfer efficiencies between the different accelerators. Over the last two years a complete renovation has been ongoing, where the old electronics, based on analogue integrators, have been replaced by a fully digital system enclosed in a single VME based card. This new system called TRIC (Transformer Integration Card) is based on a 12 bit, 212 MS/s ADC and an FPGA for the signal processing. Also located on the same board one finds a 250 V/1.5 W DCDC converter used to generate precise calibration pulses.

  17. Quantitative Measurements of X-ray Intensity

    SciTech Connect

    Haugh, M. J., Schneider, M.

    2011-09-01

    This chapter describes the characterization of several X-ray sources and their use in calibrating different types of X-ray cameras at National Security Technologies, LLC (NSTec). The cameras are employed in experimental plasma studies at Lawrence Livermore National Laboratory (LLNL), including the National Ignition Facility (NIF). The sources provide X-rays in the energy range from several hundred eV to 110 keV. The key to this effort is measuring the X-ray beam intensity accurately and traceable to international standards. This is accomplished using photodiodes of several types that are calibrated using radioactive sources and a synchrotron source using methods and materials that are traceable to the U.S. National Institute of Standards and Technology (NIST). The accreditation procedures are described. The chapter begins with an introduction to the fundamental concepts of X-ray physics. The types of X-ray sources that are used for device calibration are described. The next section describes the photodiode types that are used for measuring X-ray intensity: power measuring photodiodes, energy dispersive photodiodes, and cameras comprising photodiodes as pixel elements. Following their description, the methods used to calibrate the primary detectors, the power measuring photodiodes and the energy dispersive photodiodes, as well as the method used to get traceability to international standards are described. The X-ray source beams can then be measured using the primary detectors. The final section then describes the use of the calibrated X-ray beams to calibrate X-ray cameras. Many of the references are web sites that provide databases, explanations of the data and how it was generated, and data calculations for specific cases. Several general reference books related to the major topics are included. Papers expanding some subjects are cited.

  18. Absolute measurement of the 242Pu neutron-capture cross section

    DOE PAGES

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; et al

    2016-04-21

    Here, the absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. The first direct measurement of the 242Pu(n,γ) cross section was made over the incident neutron energy range from thermal to ≈ 6 keV, and the absolute scale of the (n,γ) cross section was set according to the known 239Pu(n,f) resonance at En,R = 7.83 eV. This was accomplished by adding a small quantity of 239Pu to the 242Pu sample. The relative scale of the crossmore » section, with a range of four orders of magnitude, was determined for incident neutron energies from thermal to ≈ 40 keV. Our data, in general, are in agreement with previous measurements and those reported in ENDF/B-VII.1; the 242Pu(n,γ) cross section at the En,R = 2.68 eV resonance is within 2.4% of the evaluated value. However, discrepancies exist at higher energies; our data are ≈30% lower than the evaluated data at En ≈ 1 keV and are approximately 2σ away from the previous measurement at En ≈ 20 keV.« less

  19. Camera-based speckle noise reduction for 3-D absolute shape measurements.

    PubMed

    Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen; Fischer, Andreas

    2016-05-30

    Simultaneous position and velocity measurements enable absolute 3-D shape measurements of fast rotating objects for instance for monitoring the cutting process in a lathe. Laser Doppler distance sensors enable simultaneous position and velocity measurements with a single sensor head by evaluating the scattered light signals. The superposition of several speckles with equal Doppler frequency but random phase on the photo detector results in an increased velocity and shape uncertainty, however. In this paper, we present a novel image evaluation method that overcomes the uncertainty limitations due to the speckle effect. For this purpose, the scattered light is detected with a camera instead of single photo detectors. Thus, the Doppler frequency from each speckle can be evaluated separately and the velocity uncertainty decreases with the square root of the number of camera lines. A reduction of the velocity uncertainty by the order of one magnitude is verified by the numerical simulations and experimental results, respectively. As a result, the measurement uncertainty of the absolute shape is not limited by the speckle effect anymore. PMID:27410133

  20. Absolute measurement of the 242Pu neutron-capture cross section

    NASA Astrophysics Data System (ADS)

    Buckner, M. Q.; Wu, C. Y.; Henderson, R. A.; Bucher, B.; Chyzh, A.; Bredeweg, T. A.; Baramsai, B.; Couture, A.; Jandel, M.; Mosby, S.; O'Donnell, J. M.; Ullmann, J. L.; Dance Collaboration

    2016-04-01

    The absolute neutron-capture cross section of 242Pu was measured at the Los Alamos Neutron Science Center using the Detector for Advanced Neutron-Capture Experiments array along with a compact parallel-plate avalanche counter for fission-fragment detection. The first direct measurement of the 242Pu(n ,γ ) cross section was made over the incident neutron energy range from thermal to ≈6 keV, and the absolute scale of the (n ,γ ) cross section was set according to the known 239Pu(n ,f ) resonance at En ,R=7.83 eV. This was accomplished by adding a small quantity of 239Pu to the 242Pu sample. The relative scale of the cross section, with a range of four orders of magnitude, was determined for incident neutron energies from thermal to ≈40 keV. Our data, in general, are in agreement with previous measurements and those reported in ENDF/B-VII.1; the 242Pu(n ,γ ) cross section at the En ,R=2.68 eV resonance is within 2.4 % of the evaluated value. However, discrepancies exist at higher energies; our data are ≈30 % lower than the evaluated data at En≈1 keV and are approximately 2 σ away from the previous measurement at En≈20 keV.

  1. Intercomparison of the LBIR Absolute Cryogenic Radiometers to the NIST Optical Power Measurement Standard

    PubMed Central

    Fedchak, James A.; Carter, Adriaan C.; Datla, Raju

    2006-01-01

    The Low Background Infrared calibration (LBIR) facility at the National Institute of Standards and Technology (NIST) presently maintains four absolute cryogenic radiometers (ACRs) which serve as standard reference detectors for infrared calibrations performed by the facility. The primary standard for optical power measurements at NIST-Gaithersburg has been the High Accuracy Cryogenic Radiometer (HACR). Recently, an improved radiometer, the Primary Optical Watt Radiometer (POWR), has replaced the HACR as the primary standard. In this paper, we present the results of comparisons between the radiometric powers measured by the four ACRs presently maintained by the LBIR facility to that measured by the HACR and POWR. This was done by using a Si photodiode light-trapping detector as a secondary transfer standard to compare the primary national standards to the ACRs maintained by the LBIR facility. The technique used to compare an ACR to the trap detector is described in detail. The absolute optical power measurements are found to be within 0.1 % of the primary standard for all the ACRs examined in this study. PMID:27274936

  2. Absolute Retinal Blood Flow Measurement With a Dual-Beam Doppler Optical Coherence Tomography

    PubMed Central

    Dai, Cuixia; Liu, Xiaojing; Zhang, Hao F.; Puliafito, Carmen A.; Jiao, Shuliang

    2013-01-01

    Purpose. To test the capability of a novel dual-beam Doppler optical coherence tomography (OCT) technique for simultaneous in vivo measurement of the Doppler angle and, thus, the absolute retinal blood velocity and the retinal flow rate, without the influence of motion artifacts. Methods. A novel dual-beam Doppler spectral domain OCT (SD-OCT) was developed. The two probing beams are separated with a controllable distance along an arbitrary direction, both of which are controlled by two independent 2D optical scanners. Two sets of optical Doppler tomography (ODT) images are acquired simultaneously. The Doppler angle of each blood vessel segment is calculated from the relative coordinates of the centers of the blood vessel in the two corresponding ODT images. The absolute blood flow velocity and the volumetric blood flow rate can then be calculated. To measure the total retinal blood flow, we used a circular scan pattern centered at the optic disc to obtain two sets of concentric OCT/ODT images simultaneously. Results. We imaged two normal human subjects at ages of 48 and 34 years. The total retinal blood flow rates of the two human subjects were calculated to be 47.01 μL/min (older subject) and 51.37 μL/min (younger subject), respectively. Results showed that the performance of this imaging system is immune to eye movement, since the two sets of ODT images were acquired simultaneously. Conclusions. The dual-beam OCT/ODT system is successful in measuring the absolute retinal blood velocity and the volumetric flow rate. The advantage of the technique is that the two sets of ODT images used for the calculation are acquired simultaneously, which eliminates the influence of eye motion and ensures the accuracy of the calculated hemodynamic parameters. PMID:24222303

  3. Measurements of the absolute branching fractions of B+/- --> K+/-X(cc).

    PubMed

    Aubert, B; Barate, R; Boutigny, D; Couderc, F; Karyotakis, Y; Lees, J P; Poireau, V; Tisserand, V; Zghiche, A; Grauges, E; Palano, A; Pappagallo, M; Pompili, A; Chen, J C; Qi, N D; Rong, G; Wang, P; Zhu, Y S; Eigen, G; Ofte, I; Stugu, B; Abrams, G S; Battaglia, M; Breon, A B; Brown, D N; Button-Shafer, J; Cahn, R N; Charles, E; Day, C T; Gill, M S; Gritsan, A V; Groysman, Y; Jacobsen, R G; Kadel, R W; Kadyk, J; Kerth, L T; Kolomensky, Yu G; Kukartsev, G; Lynch, G; Mir, L M; Oddone, P J; Orimoto, T J; Pripstein, M; Roe, N A; Ronan, M T; Wenzel, W A; Barrett, M; Ford, K E; Harrison, T J; Hart, A J; Hawkes, C M; Morgan, S E; Watson, A T; Fritsch, M; Goetzen, K; Held, T; Koch, H; Lewandowski, B; Pelizaeus, M; Peters, K; Schroeder, T; Steinke, M; Boyd, J T; Burke, J P; Chevalier, N; Cottingham, W N; Cuhadar-Donszelmann, T; Fulsom, B G; Hearty, C; Knecht, N S; Mattison, T S; McKenna, J A; Khan, A; Kyberd, P; Saleem, M; Teodorescu, L; Blinov, A E; Blinov, V E; Bukin, A D; Druzhinin, V P; Golubev, V B; Kravchenko, E A; Onuchin, A P; Serednyakov, S I; Skovpen, Yu I; Solodov, E P; Yushkov, A N; Best, D; Bondioli, M; Bruinsma, M; Chao, M; Curry, S; Eschrich, I; Kirkby, D; Lankford, A J; Lund, P; Mandelkern, M; Mommsen, R K; Roethel, W; Stoker, D P; Buchanan, C; Hartfiel, B L; Weinstein, A J R; Foulkes, S D; Gary, J W; Long, O; Shen, B C; Wang, K; Zhang, L; del Re, D; Hadavand, H K; Hill, E J; MacFarlane, D B; Paar, H P; Rahatlou, S; Sharma, V; Berryhill, J W; Campagnari, C; Cunha, A; Dahmes, B; Hong, T M; Mazur, M A; Richman, J D; Verkerke, W; Beck, T W; Eisner, A M; Flacco, C J; Heusch, C A; Kroseberg, J; Lockman, W S; Nesom, G; Schalk, T; Schumm, B A; Seiden, A; Spradlin, P; Williams, D C; Wilson, M G; Albert, J; Chen, E; Dubois-Felsmann, G P; Dvoretskii, A; Hitlin, D G; Minamora, J S; Narsky, I; Piatenko, T; Porter, F C; Ryd, A; Samuel, A; Andreassen, R; Mancinelli, G; Meadows, B T; Sokoloff, M D; Blanc, F; Bloom, P; Chen, S; Ford, W T; Hirschauer, J F; Kreisel, A; Nauenberg, U; Olivas, A; Ruddick, W O; Smith, J G; Ulmer, K A; Wagner, S R; Zhang, J; Chen, A; Eckhart, E A; Soffer, A; Toki, W H; Wilson, R J; Zeng, Q; Altenburg, D; Feltresi, E; Hauke, A; Spaan, B; Brandt, T; Brose, J; Dickopp, M; Klose, V; Lacker, H M; Nogowski, R; Otto, S; Petzold, A; Schubert, J; Schubert, K R; Schwierz, R; Sundermann, J E; Bernard, D; Bonneaud, G R; Grenier, P; Schrenk, S; Thiebaux, Ch; Vasileiadis, G; Verderi, M; Bard, D J; Clark, P J; Gradl, W; Muheim, F; Playfer, S; Xie, Y; Andreotti, M; Azzolini, V; Bettoni, D; Bozzi, C; Calabrese, R; Cibinetto, G; Luppi, E; Negrini, M; Piemontese, L; Anulli, F; Baldini-Ferroli, R; Calcaterra, A; de Sangro, R; Finocchiaro, G; Patteri, P; Peruzzi, I M; Piccolo, M; Zallo, A; Buzzo, A; Capra, R; Contri, R; Lo Vetere, M; Macri, M; Monge, M R; Passaggio, S; Patrignani, C; Robutti, E; Santroni, A; Tosi, S; Brandenburg, G; Chaisanguanthum, K S; Morii, M; Won, E; Wu, J; Dubitzky, R S; Langenegger, U; Marks, J; Schenk, S; Uwer, U; Schott, G; Bhimji, W; Bowerman, D A; Dauncey, P D; Egede, U; Flack, R L; Gaillard, J R; Nash, J A; Nikolich, M B; Vazquez, W Panduro; Chai, X; Charles, M J; Mader, W F; Mallik, U; Mohapatra, A K; Ziegler, V; Cochran, J; Crawley, H B; Eyges, V; Meyer, W T; Prell, S; Rosenberg, E I; Rubin, A E; Yi, J; Arnaud, N; Davier, M; Giroux, X; Grosdidier, G; Höcker, A; Le Diberder, F; Lepeltier, V; Lutz, A M; Oyanguren, A; Petersen, T C; Plaszczynski, S; Rodier, S; Roudeau, P; Schune, M H; Stocchi, A; Wormser, G; Cheng, C H; Lange, D J; Simani, M C; Wright, D M; Bevan, A J; Chavez, C A; Forster, I J; Fry, J R; Gabathuler, E; Gamet, R; George, K A; Hutchcroft, D E; Parry, R J; Payne, D J; Schofield, K C; Touramanis, C; Cormack, C M; Di Lodovico, F; Menges, W; Sacco, R; Brown, C L; Cowan, G; Flaecher, H U; Green, M G; Hopkins, D A; Jackson, P S; McMahon, T R; Ricciardi, S; Salvatore, F; Brown, D; Davis, C L; Allison, J; Barlow, N R; Barlow, R J; Edgar, C L; Hodgkinson, M C; Kelly, M P; Lafferty, G D; Naisbit, M T; Williams, J C; Chen, C; Hulsbergen, W D; Jawahery, A; Kovalskyi, D; Lae, C K; Roberts, D A; Simi, G; Blaylock, G; Dallapiccola, C; Hertzbach, S S; Kofler, R; Koptchev, V B; Li, X; Moore, T B; Saremi, S; Staengle, H; Willocq, S; Cowan, R; Koeneke, K; Sciolla, G; Sekula, S J; Spitznagel, M; Taylor, F; Yamamoto, R K; Kim, H; Patel, P M; Robertson, S H; Lazzaro, A; Lombardo, V; Palombo, F; Bauer, J M; Cremaldi, L; Eschenburg, V; Godang, R; Kroeger, R; Reidy, J; Sanders, D A; Summers, D J; Zhao, H W; Brunet, S; Côté, D; Taras, P; Viaud, B; Nicholson, H; Cavallo, N; De Nardo, G; Fabozzi, F; Gatto, C; Lista, L; Monorchio, D; Paolucci, P; Piccolo, D; Sciacca, C; Baak, M; Bulten, H; Raven, G; Snoek, H L; Wilden, L; Jessop, C P; Losecco, J M; Allmendinger, T; Benelli, G; Gan, K K; Honscheid, K; Hufnagel, D; Jackson, P D; Kagan, H; Kass, R; Pulliam, T; Rahimi, A M; Ter-Antonyan, R; Wong, Q K; Brau, J; Frey, R; Igonkina, O; Lu, M; Potter, C T; Sinev, N B; Strom, D; Strube, J; Torrence, E; Galeazzi, F; Margoni, M; Morandin, M; Posocco, M; Rotondo, M; Simonetto, F; Stroili, R; Voci, C; Benayoun, M; Briand, H; Chauveau, J; David, P; Del Buono, L; de la Vaissière, Ch; Hamon, O; John, M J J; Leruste, Ph; Malclès, J; Ocariz, J; Roos, L; Therin, G; Behera, P K; Gladney, L; Guo, Q H; Panetta, J; Biasini, M; Covarelli, R; Pacetti, S; Pioppi, M; Angelini, C; Batignani, G; Bettarini, S; Bucci, F; Calderini, G; Carpinelli, M; Cenci, R; Forti, F; Giorgi, M A; Lusiani, A; Marchiori, G; Morganti, M; Neri, N; Paoloni, E; Rama, M; Rizzo, G; Walsh, J; Haire, M; Judd, D; Wagoner, D E; Biesiada, J; Danielson, N; Elmer, P; Lau, Y P; Lu, C; Olsen, J; Smith, A J S; Telnov, A V; Bellini, F; Cavoto, G; D'Orazio, A; Marco, E Di; Faccini, R; Ferrarotto, F; Ferroni, F; Gaspero, M; Gioi, L Li; Mazzoni, M A; Morganti, S; Piredda, G; Polci, F; Tehrani, F Safai; Voena, C; Schröder, H; Wagner, G; Waldi, R; Adye, T; De Groot, N; Franek, B; Gopal, G P; Olaiya, E O; Wilson, F F; Aleksan, R; Emery, S; Gaidot, A; Ganzhur, S F; Graziani, G; de Monchenault, G Hamel; Kozanecki, W; Legendre, M; London, G W; Mayer, B; Vasseur, G; Yèche, Ch; Zito, M; Purohit, M V; Weidemann, A W; Wilson, J R; Yumiceva, F X; Abe, T; Allen, M T; Aston, D; Bartoldus, R; Berger, N; Boyarski, A M; Buchmueller, O L; Claus, R; Coleman, J P; Convery, M R; Cristinziani, M; Dingfelder, J C; Dong, D; Dorfan, J; Dujmic, D; Dunwoodie, W; Fan, S; Field, R C; Glanzman, T; Gowdy, S J; Hadig, T; Halyo, V; Hast, C; Hryn'ova, T; Innes, W R; Kelsey, M H; Kim, P; Kocian, M L; Leith, D W G S; Libby, J; Luitz, S; Luth, V; Lynch, H L; Marsiske, H; Messner, R; Muller, D R; O'Grady, C P; Ozcan, V E; Perazzo, A; Perl, M; Ratcliff, B N; Roodman, A; Salnikov, A A; Schindler, R H; Schwiening, J; Snyder, A; Stelzer, J; Su, D; Sullivan, M K; Suzuki, K; Swain, S K; Thompson, J M; Va'vra, J; van Bakel, N; Weaver, M; Wisniewski, W J; Wittgen, M; Wright, D H; Yarritu, A K; Yi, K; Young, C C; Burchat, P R; Edwards, A J; Majewski, S A; Petersen, B A; Roat, C; Ahmed, M; Ahmed, S; Alam, M S; Bula, R; Ernst, J A; Saeed, M A; Wappler, F R; Zain, S B; Bugg, W; Krishnamurthy, M; Spanier, S M; Eckmann, R; Ritchie, J L; Satpathy, A; Schwitters, R F; Izen, J M; Kitayama, I; Lou, X C; Ye, S; Bianchi, F; Bona, M; Gallo, F; Gamba, D; Bomben, M; Bosisio, L; Cartaro, C; Cossutti, F; Della Ricca, G; Dittongo, S; Grancagnolo, S; Lanceri, L; Vitale, L; Martinez-Vidal, F; Panvini, R S; Banerjee, Sw; Bhuyan, B; Brown, C M; Fortin, D; Hamano, K; Kowalewski, R; Roney, J M; Sobie, R J; Back, J J; Harrison, P F; Latham, T E; Mohanty, G B; Band, H R; Chen, X; Cheng, B; Dasu, S; Datta, M; Eichenbaum, A M; Flood, K T; Graham, M; Hollar, J J; Johnson, J R; Kutter, P E; Li, H; Liu, R; Mellado, B; Mihalyi, A; Pan, Y; Pierini, M; Prepost, R; Tan, P; Wu, S L; Yu, Z; Neal, H

    2006-02-10

    We study the two-body decays of B+/- mesons to K+/- and a charmonium state X(cc) in a sample of 210.5 fb(-1) of data from the BABAR experiment. We perform measurements of absolute branching fractions beta(B+/- --> K+/-X(cc)) using a missing mass technique, and report several new or improved results. In particular, the upper limit beta(B+/- --> K+/- X(3872)) < 3.2 x 10(-4) at 90% C.L. and the inferred lower limit beta(X(3872)J/psipi+ pi-) > 4.2% will help in understanding the nature of the recently discovered X(3872).

  4. The absolute CBF response to activation is preserved during elevated perfusion: Implications for neurovascular coupling measures.

    PubMed

    Whittaker, Joseph R; Driver, Ian D; Bright, Molly G; Murphy, Kevin

    2016-01-15

    Functional magnetic resonance imaging (fMRI) techniques in which the blood oxygenation level dependent (BOLD) and cerebral blood flow (CBF) response to a neural stimulus are measured, can be used to estimate the fractional increase in the cerebral metabolic rate of oxygen consumption (CMRO2) that accompanies evoked neural activity. A measure of neurovascular coupling is obtained from the ratio of fractional CBF and CMRO2 responses, defined as n, with the implicit assumption that relative rather than absolute changes in CBF and CMRO2 adequately characterise the flow-metabolism response to neural activity. The coupling parameter n is important in terms of its effect on the BOLD response, and as potential insight into the flow-metabolism relationship in both normal and pathological brain function. In 10 healthy human subjects, BOLD and CBF responses were measured to test the effect of baseline perfusion (modulated by a hypercapnia challenge) on the coupling parameter n during graded visual stimulation. A dual-echo pulsed arterial spin labelling (PASL) sequence provided absolute quantification of CBF in baseline and active states as well as relative BOLD signal changes, which were used to estimate CMRO2 responses to the graded visual stimulus. The absolute CBF response to the visual stimuli were constant across different baseline CBF levels, meaning the fractional CBF responses were reduced at the hyperperfused baseline state. For the graded visual stimuli, values of n were significantly reduced during hypercapnia induced hyperperfusion. Assuming the evoked neural responses to the visual stimuli are the same for both baseline CBF states, this result has implications for fMRI studies that aim to measure neurovascular coupling using relative changes in CBF. The coupling parameter n is sensitive to baseline CBF, which would confound its interpretation in fMRI studies where there may be significant differences in baseline perfusion between groups. The absolute change in

  5. Absolute beam flux measurement at NDCX-I using gold-melting calorimetry technique

    SciTech Connect

    Ni, P.A.; Bieniosek, F.M.; Lidia, S.M.; Welch, J.

    2011-04-01

    We report on an alternative way to measure the absolute beam flux at the NDCX-I, LBNL linear accelerator. Up to date, the beam flux is determined from the analysis of the beam-induced optical emission from a ceramic scintilator (Al-Si). The new approach is based on calorimetric technique, where energy flux is deduced from the melting dynamics of a gold foil. We estimate an average 260 kW/cm2 beam flux over 5 {micro}s, which is consistent with values provided by the other methods. Described technique can be applied to various ion species and energies.

  6. White-light scanning interferometer for absolute nano-scale gap thickness measurement.

    PubMed

    Xu, Zhiguang; Shilpiekandula, Vijay; Youcef-toumi, Kamal; Yoon, Soon Fatt

    2009-08-17

    A special configuration of white-light scanning interferometer is described for measuring the absolute air gap thickness between two planar plates brought into close proximity. The measured gap is not located in any interference arm of the interferometer, but acts as an amplitude-and-phase modulator of the light source. Compared with the common white-light interferometer our approach avoids the influence of the chromatic dispersion of the planar plates on the gap thickness quantification. It covers a large measurement range of from approximate contact to tens of microns with a high resolution of 0.1 nm. Detailed analytical models are presented and signal-processing algorithms based on convolution and correlation techniques are developed. Practical measurements are carried out and the experimental results match well with the analysis and simulation. Short-time and long-time repeatabilities are both tested to prove the high performance of our method.

  7. Absolute distance measurement with extension of nonambiguity range using the frequency comb of a femtosecond laser

    NASA Astrophysics Data System (ADS)

    Jang, Yoon-Soo; Lee, Keunwoo; Han, Seongheum; Lee, Joohyung; Kim, Young-Jin; Kim, Seung-Woo

    2014-12-01

    We revisit the method of synthetic wavelength interferometry (SWI) for absolute measurement of long distances using the radio-frequency harmonics of the pulse repetition rate of a mode-locked femtosecond laser. Our intention here is to extend the nonambiguity range (NAR) of the SWI method using a coarse virtual wavelength synthesized by shifting the pulse repetition rate. The proposed concept of NAR extension is experimentally verified by measuring a ˜13-m distance with repeatability of 9.5 μm (root-mean-square). The measurement precision is estimated to be 31.2 μm in comparison with an incremental He-Ne laser interferometer. This extended SWI method is found to be well suited for long-distance measurements demanded in the fields of large-scale precision engineering, geodetic survey, and future space missions.

  8. Absolute Density Calibration Cell for Laser Induced Fluorescence Erosion Rate Measurements

    NASA Technical Reports Server (NTRS)

    Domonkos, Matthew T.; Stevens, Richard E.

    2001-01-01

    Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser-induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. This work examines the suitability of the density cell as an absolute calibration source for LIF measurements, and the intrinsic error was evaluated.

  9. High-resolution measurement of absolute {alpha}-decay widths in {sup 16}O

    SciTech Connect

    Wheldon, C.; Ashwood, N. I.; Barr, M.; Curtis, N.; Freer, M.; Kokalova, Tz.; Malcolm, J. D.; Spencer, S. J.; Ziman, V. A.; Faestermann, Th.; Kruecken, R.; Wirth, H.-F.; Hertenberger, R.; Lutter, R.; Bergmaier, A.

    2011-06-15

    By using a large-acceptance position-sensitive silicon detector array in coincidence with the high-resolution Munich Q3D spectrograph, unambiguous measurements have been made of the absolute {alpha}-particle decay widths from excited states in {sup 16}O* in the energy range 13.85 to 15.87 MeV. Carbon targets have been bombarded with 42-MeV {sup 6}Li beams to induce {sub 6}{sup 12}C({sub 3}{sup 6}Li, d){sub 8}{sup 16}O* reactions. The deuteron ejectiles were measured in the Q3D and the results gated by {sup 4}He+{sup 12}C breakup products detected in the silicon array, the efficiency of which was modeled using Monte Carlo simulations. By comparing total population and breakup-gated spectra, the following absolute {alpha}-decay widths have been measured with high resolution: {Gamma}{sub {alpha}}0/{Gamma}{sub tot} = 0.87{+-}0.11 (13.980 MeV), 1.04{+-}0.15 (14.302 MeV), 0.92{+-}0.10 (14.399 MeV), 0.59{+-}0.04 (14.815 MeV), 0.88{+-}0.18 (15.785 MeV), and {Gamma}{sub {alpha}}1/{Gamma}{sub tot}=1.14{+-}0.08 (14.660 MeV), 0.46{+-}0.06 (14.815 MeV).

  10. Absolute specific heat measurements of a microgram Pb crystal using ac nanocalorimetry

    NASA Astrophysics Data System (ADS)

    Tagliati, S.; Rydh, A.

    2012-12-01

    Heat capacity measurements using the ac steady state method are often considered difficult to provide absolute accuracy. By adjusting the working frequency to maintain a constant phase and using the phase information to obtain the heat capacity, we have found that it is possible to achieve good absolute accuracy. Here we present a thermodynamic study of a ~ 2.6 μg Pb superconducting crystal to demonstrate the newly opened capabilities. The sample is measured using a differential membrane-based calorimeter. The custom-made calorimetric cell is a pile of thin film Ti heater, insulation layer and Ge1-xAux thermometer fabricated in the center of two Si3N4 membranes. It has a background heat capacity < 100 nJ/K at 300 K, decreasing to 9 pJ/K at 1 K. The sample is characterized at temperatures down to 0.5 K. The zero field transition at Tc = 7.21 K has a width asymp 20 mK and displays no upturn in C. From the heat capacity jump at Tc and the extrapolated Sommerfeld term we find ΔC/γTc = 2.68. The latent heat curve obtained from the zero field heat capacity measurement, and the deviations of the thermodynamic critical field from the empirical expression Hc = Hc (0) [1 - (T/Tc)2] are discussed. Both analyses give results in good agreement with literature.

  11. PREMOS Absolute Radiometer Calibration and Implications to on-orbit Measurements of the Total Solar Irradiance

    NASA Astrophysics Data System (ADS)

    Fehlmann, A.; Kopp, G.; Schmutz, W. K.; Winkler, R.; Finsterle, W.; Fox, N.

    2011-12-01

    On orbit measurements starting in the late 1970's, have revealed the 11 year cycle of the Total Solar Irradiance (TSI). However, the absolute results from individual experiments differ although all instrument teams claim to measure an absolute value. Especially the data from the TIM/SORCE experiment confused the community as it measures 0.3 % lower than the other instruments, e.g. VIRGO/SOHO by PMOD/WRC, which clearly exceeds the uncertainty stated for the absolute characterization of the experiments. The PREMOS package on the PICARD platform launched in June 2010 is the latest space experiment by PMOD/WRC measuring the TSI. We have put great effort in the calibration and characterization of this instrument in order to resolve the inter-instrument differences. We performed calibrations at the National Physical Laboratory (NPL) in London and the Laboratory for Atmospheric and Space Physics (LASP) in Boulder against national SI standards for radiant power using a laser beam with a diameter being smaller than the aperture of the instrument. These measurements together with the World Radiometric Reference (WRR) calibration in Davos allowed to compare the WRR and the SI radiant power scale. We found that the WRR lies 0.18 % above the SI radiant power scale which explains a part of the VIRGO-TIM difference. The Total solar irradiance Radiometer Facility (TRF) at the LASP allows to generate a beam that over fills the apertures of our instruments, giving the presently best available representation of solar irradiance in a laboratory. These irradiance calibrations revealed a stray light contribution between 0.09 and 0.3 % to the measurements which had been underestimated in the characterization of our instruments. Using the irradiance calibrations, we found that the WRR lies 0.32 % above the TRF scale which in turn explains the full VIRGO-TIM difference. The first light PREMOS measurements in space confirmed our findings. If we use the WRR calibration, PREMOS yields a TSI

  12. Dispersive white-light interferometry for absolute distance measurement with dielectric multilayer systems on the target.

    PubMed

    Schnell, U; Dändliker, R; Gray, S

    1996-04-01

    We have extended the use of a dispersive white-light interferometer for absolute distance measurement to include effects of dielectric multilayer systems on the target. The phase of the ref lected wave changes as a function of wavelength and layer thickness and causes errors in the interferometric distance measurement. With dispersive white-light interferometry these effects can be measured in situ, and the correct mechanical distance can be determined. The effects of thin films deposited upon the target have been investigated for one and two layers (photoresist and SiO(2) upon Si). Experimental results show that the thicknesses of these layers can also be determined with an accuracy of the order of 10 nm.

  13. ABSOLUTE MEASUREMENT OF THE POLARIZATION OF HIGH ENERGY PROTON BEAMS AT RHIC

    SciTech Connect

    MAKDISI,Y.; BRAVAR, A. BUNCE, G. GILL, R.; HUANG, H.; ET AL.

    2007-06-25

    The spin physics program at the Relativistic Heavy Ion Collider (RHIC) requires knowledge of the beam polarization to better than 5%. Such a goal is made the more difficult by the lack of knowledge of the analyzing power of high energy nuclear physics processes. To overcome this, a polarized hydrogen jet target was constructed and installed at one intersection region in RHIC where it intersects both beams and utilizes the precise knowledge of the jet atomic hydrogen beam polarization to measure the analyzing power in proton-proton elastic scattering in the Nuclear Coulomb Interference (CNI) region at the prescribed RHIC proton beam energy. The reverse reaction is used to assess the absolute beam polarization. Simultaneous measurements taken with fast high statistics polarimeters that measure the p-Carbon elastic scattering process also in the CNI region use the jet results to calibrate the latter.

  14. Calibration of Fourier domain short coherence interferometer for absolute distance measurements.

    PubMed

    Montonen, R; Kassamakov, I; Hæggström, E; Österberg, K

    2015-05-20

    We calibrated and determined the measurement uncertainty of a custom-made Fourier domain short coherence interferometer operated in laboratory conditions. We compared the optical thickness of two thickness standards and three coverslips determined with our interferometer to the geometric thickness determined by SEM. Using this calibration data, we derived a calibration function with a 95% confidence level system uncertainty of (5.9×10(-3)r+2.3)  μm, where r is the optical distance in μm, across the 240 μm optical measurement range. The confidence limit includes contributions from uncertainties in the optical thickness, geometric thickness, and refractive index measurements as well as uncertainties arising from cosine errors and thermal expansion. The results show feasibility for noncontacting absolute distance characterization with micrometer-level accuracy. This instrument is intended for verifying the alignment of the discs of an accelerating structure in the possible future compact linear collider.

  15. Absolute reliability of isokinetic knee flexion and extension measurements adopting a prone position.

    PubMed

    Ayala, F; De Ste Croix, M; Sainz de Baranda, P; Santonja, F

    2013-01-01

    The main purpose of this study was to determine the absolute and relative reliability of isokinetic peak torque (PT), angle of peak torque (APT), average power (PW) and total work (TW) for knee flexion and extension during concentric and eccentric actions measured in a prone position at 60, 180 and 240° s(-1). A total of 50 recreational athletes completed the study. PT, APT, PW and TW for concentric and eccentric knee extension and flexion were recorded at three different angular velocities (60, 180 and 240° s(-1)) on three different occasions with a 72- to 96-h rest interval between consecutive testing sessions. Absolute reliability was examined through typical percentage error (CV(TE)), percentage change in the mean (ChM) and relative reliability with intraclass correlations (ICC(3,1)). For both the knee extensor and flexor muscle groups, all strength data (except APT during knee flexion movements) demonstrated moderate absolute reliability (ChM < 3%; ICCs > 0·70; and CV(TE) < 20%) independent of the knee movement (flexion and extension), type of muscle action (concentric and eccentric) and angular velocity (60, 180 and 240° s(-1)). Therefore, the current study suggests that the CV(TE) values reported for PT (8-20%), APT (8-18%) (only during knee extension movements), PW (14-20%) and TW (12-28%) may be acceptable to detect the large changes usually observed after rehabilitation programmes, but not acceptable to examine the effect of preventative training programmes in healthy individuals.

  16. Microfabricated Collector-Generator Electrode Sensor for Measuring Absolute pH and Oxygen Concentrations.

    PubMed

    Dengler, Adam K; Wightman, R Mark; McCarty, Gregory S

    2015-10-20

    Fast-scan cyclic voltammetry (FSCV) has attracted attention for studying in vivo neurotransmission due to its subsecond temporal resolution, selectivity, and sensitivity. Traditional FSCV measurements use background subtraction to isolate changes in the local electrochemical environment, providing detailed information on fluctuations in the concentration of electroactive species. This background subtraction removes information about constant or slowly changing concentrations. However, determination of background concentrations is still important for understanding functioning brain tissue. For example, neural activity is known to consume oxygen and produce carbon dioxide which affects local levels of oxygen and pH. Here, we present a microfabricated microelectrode array which uses FSCV to detect the absolute levels of oxygen and pH in vitro. The sensor is a collector-generator electrode array with carbon microelectrodes spaced 5 μm apart. In this work, a periodic potential step is applied at the generator producing transient local changes in the electrochemical environment. The collector electrode continuously performs FSCV enabling these induced changes in concentration to be recorded with the sensitivity and selectivity of FSCV. A negative potential step applied at the generator produces a transient local pH shift at the collector. The generator-induced pH signal is detected using FSCV at the collector and correlated to absolute solution pH by postcalibration of the anodic peak position. In addition, in oxygenated solutions a negative potential step at the generator produces hydrogen peroxide by reducing oxygen. Hydrogen peroxide is detected with FSCV at the collector electrode, and the magnitude of the oxidative peak is proportional to absolute oxygen concentrations. Oxygen interference on the pH signal is minimal and can be accounted for with a postcalibration.

  17. Measurements of absolute absorption cross sections of ozone in the 185- to 254-nm wavelength region and the temperature dependence

    NASA Technical Reports Server (NTRS)

    Yoshino, K.; Esmond, J. R.; Freeman, D. E.; Parkinson, W. H.

    1993-01-01

    Laboratory measurements of the relative absorption cross sections of ozone at temperatures 195, 228, and 295 K have been made throughout the 185 to 254 nm wavelength region. The absolute absorption cross sections at the same temperatures have been measured at several discrete wavelengths in the 185 to 250 nm region. The absolute cross sections of ozone have been used to put the relative cross sections on a firm absolute basis throughout the 185 to 255 nm region. These recalibrated cross sections are slightly lower than those of Molina and Molina (1986), but the differences are within a few percent and would not be significant in atmospheric applications.

  18. Absolute wind measurements in the lower thermosphere of Venus using infrared heterodyne spectroscopy

    NASA Technical Reports Server (NTRS)

    Goldstein, Jeffrey J.

    1990-01-01

    The first absolute wind velocities above the Venusian cloud-tops were obtained using NASA/Goddard infrared heterodyne spectrometers at the NASA Infrared Telescope Facility (IRTF) and the McMath Solar Telescope. Beam-integrated Doppler displacements in the non-thermal emission core of (12)C(16)O2 10.33 micron R(8) sampled the line of sight projection of the lower thermospheric wind field (100 to 120 km). A field-usable Lamb-dip laser stabilization system, developed for spectrometer absolute frequency calibration to less than + or - 0.1 MHz, allowed S/N-limited line of sight velocity resolution at the 1 m/s level. The spectrometer's diffraction-limited beam (1.7 arc-second HPBW at McMath, 0.9 arc-second HPBW at IRTF), and 1 to 2 arc-second seeing, provided the spatial resolution necessary for circulation model discrimination. Qualitative analysis of beam-integrated winds provided definitive evidence of a dominant subsolar-antisolar circulation in the lower thermosphere. Beam-integrated winds were modelled with a 100x100 grid over the beam, incorporating beam spatial rolloff and across-the-beam gradients in non-thermal emission intensity, line of sight projection geometry, and horizontal wind velocity. Horizontal wind velocity was derived from a 2-parameter model wind field comprised of subsolar-antisolar and zonal components. Best-fit models indicated a dominant subsolar-antisolar flow with 120 m/s cross-terminator winds and a retrograde zonal component with a 25 m/s equatorial velocity. A review of all dynamical indicators above the cloud-tops allowed development of an integrated and self-consistent picture of circulation in the 70 to 200 km range.

  19. Small angle neutron scattering on an absolute intensity scale and the internal surface of diatom frustules from three species of differing morphologies.

    PubMed

    Garvey, C J; Strobl, M; Percot, A; Saroun, J; Haug, J; Vyverman, W; Chepurnov, V A; Ferris, J M

    2013-05-01

    The internal nanostructure of the diatoms Cyclotella meneghiniana, Seminavis robusta and Achnanthes subsessilis was investigated using small angle neutron scattering (SANS) to examine thin biosilica samples, consisting of isotropic (powder) from their isolated cell walls. The interpretation of SANS data was assisted by several other measurements. The N2 adsorption, interpreted within the Branuer-Emmet-Teller isotherm, yielded the specific surface area of the material. Fourier transform infrared (FTIR) and Raman spectroscopy indicates that the isolated material is amorphous silica with small amounts of organic cell wall materials acting as a filling material between the silica particles. A two-phase (air and amorphous silica) model was used to interpret small angle neutron scattering data. After correction for instrumental resolution, the measurements on two SANS instruments covered an extended range of scattering vectors 0.0011 nm(-1) < q < 5.6 nm(-1), giving an almost continuous SANS curve over a range of scattering vectors, q, on an absolute scale of intensity for each sample. Each of the samples gave a characteristic scattering curve where log (intensity) versus log (q) has a -4 dependence, with other features superimposed. In the high-q regime, departure from this behaviour was observed at a length-scales equivalent to the proposed unitary silica particle. The limiting Porod scattering law was used to determine the specific area per unit of volume of each sample illuminated by the neutron beam. The Porod behaviour, and divergence from this behaviour, is discussed in terms of various structural features and the proposed mechanisms for the bio-assembly of unitary silica particles in frustules.

  20. Absolute absorption cross-section measurements of ozone in the wavelength region 238-335 nm and the temperature dependence

    NASA Technical Reports Server (NTRS)

    Yoshino, K.; Freeman, D. E.; Esmond, J. R.; Parkinson, W. H.

    1988-01-01

    The absolute absorption cross-section of ozone has been experimentally determined at the temperatures 195, 228, and 295 K at several discrete wavelengths in the 238-335-nm region. The present results for ozone at 295 K are found to be in agreement with those of Hearn (1961). Absolute cross-section measurements of ozone at 195 K have confirmed previous (Freeman et al., 1984) relative cross-section measurements throughout the 240-335-nm region.

  1. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

    SciTech Connect

    Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Seguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Magoon, J.; Meyerhofer, D. D.; Sangster, T. C.; Shoup, M.; Ulreich, J.; Ashabranner, R. C.; Bionta, R. M.; Carpenter, A. C.; Felker, B.; Khater, H. Y.; LePape, S.; MacKinnon, A.; McKernan, M. A.; Moran, M.; Rygg, J. R.; Yeoman, M. F.; Zacharias, R.; Leeper, R. J.; Fletcher, K.; Farrell, M.; Jasion, D.; Kilkenny, J.; Paguio, R.

    2013-04-18

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  2. Radioactivity measurements of 177Lu, 111In and 123I by different absolute methods.

    PubMed

    Rezende, E A; Correia, A R; Iwahara, A; da Silva, C J; Tauhata, L; Poledna, R; da Silva, R L; de Oliveira, E M; de Oliveira, A E

    2012-09-01

    The activities of (177)Lu, (111)In and (123)I solutions have been absolutely determined using three different measurement methods. (177)Lu solution was standardized using the 4πβ(PC)-γ(NaI) coincidence and 4πβ(LS)-γ(NaI) live-timed anticoincidence methods. For the (111)In and (123)I solutions, besides these two mentioned methods, the coincidence sum-peak method was also applied. The measured activities results using these different methods are consistent within the evaluated experimental uncertainties demonstrating the equivalence of these methods. As an additional contribution to nuclear data, the half-lives have been determined using a well type IG12 ionization chamber.

  3. Absolute density measurement of SD radicals in a supersonic jet at the quantum-noise-limit.

    PubMed

    Mizouri, Arin; Deng, L Z; Eardley, Jack S; Nahler, N Hendrik; Wrede, Eckart; Carty, David

    2013-12-01

    The absolute density of SD radicals in a supersonic jet has been measured down to (1.1 ± 0.1) × 10(5) cm(-3) in a modestly specified apparatus that uses a cross-correlated combination of cavity ring-down and laser-induced fluorescence detection. Such a density corresponds to 215 ± 21 molecules in the probe volume at any given time. The minimum detectable absorption coefficient was quantum-noise-limited and measured to be (7.9 ± 0.6) × 10(-11) cm(-1), in 200 s of acquisition time, corresponding to a noise-equivalent absorption sensitivity for the apparatus of (1.6 ± 0.1) × 10(-9) cm(-1) Hz(-1/2).

  4. Comb-calibrated frequency-modulated continuous-wave ladar for absolute distance measurements.

    PubMed

    Baumann, Esther; Giorgetta, Fabrizio R; Coddington, Ian; Sinclair, Laura C; Knabe, Kevin; Swann, William C; Newbury, Nathan R

    2013-06-15

    We demonstrate a comb-calibrated frequency-modulated continuous-wave laser detection and ranging (FMCW ladar) system for absolute distance measurements. The FMCW ladar uses a compact external cavity laser that is swept quasi-sinusoidally over 1 THz at a 1 kHz rate. The system simultaneously records the heterodyne FMCW ladar signal and the instantaneous laser frequency at sweep rates up to 3400 THz/s, as measured against a free-running frequency comb (femtosecond fiber laser). Demodulation of the ladar signal against the instantaneous laser frequency yields the range to the target with 1 ms update rates, bandwidth-limited 130 μm resolution and a ~100 nm accuracy that is directly linked to the counted repetition rate of the comb. The precision is <100 nm at the 1 ms update rate and reaches ~6 nm for a 100 ms average. PMID:23938965

  5. Absolute ultrasonic displacement amplitude measurements with a submersible electrostatic acoustic transducer

    NASA Technical Reports Server (NTRS)

    Yost, William T.; Cantrell, John H.

    1992-01-01

    An experimental technique for absolute measurement of ultrasonic wave particle displacement amplitudes in liquids is reported. The technique is capable of measurements over a frequency range of two decades with a sensitivity less than one angstrom. The technique utilizes a previously reported submersible electrostatic acoustic transducer (ESAT) featuring a conductive membrane stretched over a recessed electrode. An uncertainty analysis shows that the displacement amplitude of an ultrasonic plane wave incident on the ESAT can be experimentally determined to better than 2.3-4 percent, depending on frequency, in the frequency range of 0.5-15 MHz. Membranes with lower and more uniform areal densities can improve the accuracy and extend the operation to higher frequencies.

  6. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF.

    PubMed

    Casey, D T; Frenje, J A; Johnson, M Gatu; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Magoon, J; Meyerhofer, D D; Sangster, T C; Shoup, M; Ulreich, J; Ashabranner, R C; Bionta, R M; Carpenter, A C; Felker, B; Khater, H Y; LePape, S; MacKinnon, A; McKernan, M A; Moran, M; Rygg, J R; Yeoman, M F; Zacharias, R; Leeper, R J; Fletcher, K; Farrell, M; Jasion, D; Kilkenny, J; Paguio, R

    2013-04-01

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  7. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

    SciTech Connect

    Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Seguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Magoon, J.; Meyerhofer, D. D.; Sangster, T. C.; Shoup, M.; Ulreich, J.; Ashabranner, R. C.; Bionta, R. M.; Carpenter, A. C.; Felker, B.; Khater, H. Y.; LePape, S.; MacKinnon, A.; and others

    2013-04-15

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  8. Using a dose-area product for absolute measurements in small fields: a feasibility study.

    PubMed

    Dufreneix, S; Ostrowsky, A; Le Roy, M; Sommier, L; Gouriou, J; Delaunay, F; Rapp, B; Daures, J; Bordy, J-M

    2016-01-21

    To extend the dosimetric reference system to field sizes smaller than 2 cm × 2 cm, the LNE-LNHB laboratory is studying an approach based on a new dosimetric quantity named the dose-area product instead of the commonly used absorbed dose at a point. A graphite calorimeter and a plane parallel ion chamber with a sensitive surface of 3 cm diameter were designed and built for measurements in fields of 2, 1 and 0.75 cm diameter. The detector surface being larger than the beam section, most of the issues linked with absolute dose measurements at a point could be avoided. Calibration factors of the plane parallel ionization chamber were established in terms of dose-area product in water for small fields with an uncertainty smaller than 0.9%. PMID:26690271

  9. Diagnostics principle of microwave cut-off probe for measuring absolute electron density

    SciTech Connect

    Jun, Hyun-Su

    2014-08-15

    A generalized diagnostics principle of microwave cut-off probe is presented with a full analytical solution. In previous studies on the microwave cut-off measurement of weakly ionized plasmas, the cut-off frequency ω{sub c} of a given electron density is assumed to be equal to the plasma frequency ω{sub p} and is predicted using electromagnetic simulation or electric circuit model analysis. However, for specific plasma conditions such as highly collisional plasma and a very narrow probe tip gap, it has been found that ω{sub c} and ω{sub p} are not equal. To resolve this problem, a generalized diagnostics principle is proposed by analytically solving the microwave cut-off condition Re[ε{sub r,eff}(ω = ω{sub c})] = 0. In addition, characteristics of the microwave cut-off condition are theoretically tested for correct measurement of the absolute electron density.

  10. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

    DOE PAGES

    Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Seguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Magoon, J.; Meyerhofer, D. D.; et al

    2013-04-18

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describesmore » ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.« less

  11. Radioactivity measurements of 177Lu, 111In and 123I by different absolute methods.

    PubMed

    Rezende, E A; Correia, A R; Iwahara, A; da Silva, C J; Tauhata, L; Poledna, R; da Silva, R L; de Oliveira, E M; de Oliveira, A E

    2012-09-01

    The activities of (177)Lu, (111)In and (123)I solutions have been absolutely determined using three different measurement methods. (177)Lu solution was standardized using the 4πβ(PC)-γ(NaI) coincidence and 4πβ(LS)-γ(NaI) live-timed anticoincidence methods. For the (111)In and (123)I solutions, besides these two mentioned methods, the coincidence sum-peak method was also applied. The measured activities results using these different methods are consistent within the evaluated experimental uncertainties demonstrating the equivalence of these methods. As an additional contribution to nuclear data, the half-lives have been determined using a well type IG12 ionization chamber. PMID:22401938

  12. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

    NASA Astrophysics Data System (ADS)

    Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Séguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Magoon, J.; Meyerhofer, D. D.; Sangster, T. C.; Shoup, M.; Ulreich, J.; Ashabranner, R. C.; Bionta, R. M.; Carpenter, A. C.; Felker, B.; Khater, H. Y.; LePape, S.; MacKinnon, A.; McKernan, M. A.; Moran, M.; Rygg, J. R.; Yeoman, M. F.; Zacharias, R.; Leeper, R. J.; Fletcher, K.; Farrell, M.; Jasion, D.; Kilkenny, J.; Paguio, R.

    2013-04-01

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  13. Digital encoding of cellular mRNAs enabling precise and absolute gene expression measurement by single-molecule counting.

    PubMed

    Fu, Glenn K; Wilhelmy, Julie; Stern, David; Fan, H Christina; Fodor, Stephen P A

    2014-03-18

    We present a new approach for the sensitive detection and accurate quantitation of messenger ribonucleic acid (mRNA) gene transcripts in single cells. First, the entire population of mRNAs is encoded with molecular barcodes during reverse transcription. After amplification of the gene targets of interest, molecular barcodes are counted by sequencing or scored on a simple hybridization detector to reveal the number of molecules in the starting sample. Since absolute quantities are measured, calibration to standards is unnecessary, and many of the relative quantitation challenges such as polymerase chain reaction (PCR) bias are avoided. We apply the method to gene expression analysis of minute sample quantities and demonstrate precise measurements with sensitivity down to sub single-cell levels. The method is an easy, single-tube, end point assay utilizing standard thermal cyclers and PCR reagents. Accurate and precise measurements are obtained without any need for cycle-to-cycle intensity-based real-time monitoring or physical partitioning into multiple reactions (e.g., digital PCR). Further, since all mRNA molecules are encoded with molecular barcodes, amplification can be used to generate more material for multiple measurements and technical replicates can be carried out on limited samples. The method is particularly useful for small sample quantities, such as single-cell experiments. Digital encoding of cellular content preserves true abundance levels and overcomes distortions introduced by amplification.

  14. Digital Encoding of Cellular mRNAs Enabling Precise and Absolute Gene Expression Measurement by Single-Molecule Counting

    PubMed Central

    2014-01-01

    We present a new approach for the sensitive detection and accurate quantitation of messenger ribonucleic acid (mRNA) gene transcripts in single cells. First, the entire population of mRNAs is encoded with molecular barcodes during reverse transcription. After amplification of the gene targets of interest, molecular barcodes are counted by sequencing or scored on a simple hybridization detector to reveal the number of molecules in the starting sample. Since absolute quantities are measured, calibration to standards is unnecessary, and many of the relative quantitation challenges such as polymerase chain reaction (PCR) bias are avoided. We apply the method to gene expression analysis of minute sample quantities and demonstrate precise measurements with sensitivity down to sub single-cell levels. The method is an easy, single-tube, end point assay utilizing standard thermal cyclers and PCR reagents. Accurate and precise measurements are obtained without any need for cycle-to-cycle intensity-based real-time monitoring or physical partitioning into multiple reactions (e.g., digital PCR). Further, since all mRNA molecules are encoded with molecular barcodes, amplification can be used to generate more material for multiple measurements and technical replicates can be carried out on limited samples. The method is particularly useful for small sample quantities, such as single-cell experiments. Digital encoding of cellular content preserves true abundance levels and overcomes distortions introduced by amplification. PMID:24579851

  15. A new method for the absolute radiance calibration for UV-vis measurements of scattered sunlight

    NASA Astrophysics Data System (ADS)

    Wagner, T.; Beirle, S.; Dörner, S.; Penning de Vries, M.; Remmers, J.; Rozanov, A.; Shaiganfar, R.

    2015-10-01

    Absolute radiometric calibrations are important for measurements of the atmospheric spectral radiance. Such measurements can be used to determine actinic fluxes, the properties of aerosols and clouds, and the shortwave energy budget. Conventional calibration methods in the laboratory are based on calibrated light sources and reflectors and are expensive, time consuming and subject to relatively large uncertainties. Also, the calibrated instruments might change during transport from the laboratory to the measurement sites. Here we present a new calibration method for UV-vis instruments that measure the spectrally resolved sky radiance, for example zenith sky differential optical absorption spectroscopy (DOAS) instruments or multi-axis (MAX)-DOAS instruments. Our method is based on the comparison of the solar zenith angle dependence of the measured zenith sky radiance with radiative transfer simulations. For the application of our method, clear-sky measurements during periods with almost constant aerosol optical depth are needed. The radiative transfer simulations have to take polarisation into account. We show that the calibration results are almost independent from the knowledge of the aerosol optical properties and surface albedo, which causes a rather small uncertainty of about < 7 %. For wavelengths below about 330 nm it is essential that the ozone column density during the measurements be constant and known.

  16. Easy Absolute Values? Absolutely

    ERIC Educational Resources Information Center

    Taylor, Sharon E.; Mittag, Kathleen Cage

    2015-01-01

    The authors teach a problem-solving course for preservice middle-grades education majors that includes concepts dealing with absolute-value computations, equations, and inequalities. Many of these students like mathematics and plan to teach it, so they are adept at symbolic manipulations. Getting them to think differently about a concept that they…

  17. Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements

    PubMed Central

    Tozawa, Ryosuke; Katoh, Munenori; Aramaki, Hidefumi; Kawasaki, Tsubasa; Nishikawa, Yuichi; Kumamoto, Tsuneo; Fujinawa, Osamu

    2016-01-01

    [Purpose] The intra- and inter-examiner reliabilities of lumbar interspinous process distances measured by ultrasound imaging were examined. [Subjects and Methods] The subjects were 10 males who had no history of orthopedic diseases or dysfunctions. Ten lumbar interspinous images from 360 images captured from 10 subjects were selected. The 10 images were measured by nine examiners. The lumbar interspinous process distance measurements were performed five times by each examiner. In addition, four of the nine examiners measured the distances again after 4 days for test-retest analysis. In statistical analysis, the intraclass correlation coefficient was used to investigate relative reliability, and Bland-Altman analysis was used to investigate absolute reliability. [Results] The intraclass correlation coefficients (1, 1) for intra-examiner reliability ranged from 0.985 to 0.998. For inter-rater reliability, the intraclass correlation coefficient (2, 1) was 0.969. The intraclass correlation coefficients (1, 2) for test-retest reliability ranged from 0.991 to 0.999. The Bland-Altman analysis results indicated no systematic error. [Conclusion] The results indicate that ultrasound measurements of interspinous process distance are highly reliable even when measured only once by a single person.

  18. Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements.

    PubMed

    Tozawa, Ryosuke; Katoh, Munenori; Aramaki, Hidefumi; Kawasaki, Tsubasa; Nishikawa, Yuichi; Kumamoto, Tsuneo; Fujinawa, Osamu

    2016-08-01

    [Purpose] The intra- and inter-examiner reliabilities of lumbar interspinous process distances measured by ultrasound imaging were examined. [Subjects and Methods] The subjects were 10 males who had no history of orthopedic diseases or dysfunctions. Ten lumbar interspinous images from 360 images captured from 10 subjects were selected. The 10 images were measured by nine examiners. The lumbar interspinous process distance measurements were performed five times by each examiner. In addition, four of the nine examiners measured the distances again after 4 days for test-retest analysis. In statistical analysis, the intraclass correlation coefficient was used to investigate relative reliability, and Bland-Altman analysis was used to investigate absolute reliability. [Results] The intraclass correlation coefficients (1, 1) for intra-examiner reliability ranged from 0.985 to 0.998. For inter-rater reliability, the intraclass correlation coefficient (2, 1) was 0.969. The intraclass correlation coefficients (1, 2) for test-retest reliability ranged from 0.991 to 0.999. The Bland-Altman analysis results indicated no systematic error. [Conclusion] The results indicate that ultrasound measurements of interspinous process distance are highly reliable even when measured only once by a single person. PMID:27630399

  19. Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements

    PubMed Central

    Tozawa, Ryosuke; Katoh, Munenori; Aramaki, Hidefumi; Kawasaki, Tsubasa; Nishikawa, Yuichi; Kumamoto, Tsuneo; Fujinawa, Osamu

    2016-01-01

    [Purpose] The intra- and inter-examiner reliabilities of lumbar interspinous process distances measured by ultrasound imaging were examined. [Subjects and Methods] The subjects were 10 males who had no history of orthopedic diseases or dysfunctions. Ten lumbar interspinous images from 360 images captured from 10 subjects were selected. The 10 images were measured by nine examiners. The lumbar interspinous process distance measurements were performed five times by each examiner. In addition, four of the nine examiners measured the distances again after 4 days for test-retest analysis. In statistical analysis, the intraclass correlation coefficient was used to investigate relative reliability, and Bland-Altman analysis was used to investigate absolute reliability. [Results] The intraclass correlation coefficients (1, 1) for intra-examiner reliability ranged from 0.985 to 0.998. For inter-rater reliability, the intraclass correlation coefficient (2, 1) was 0.969. The intraclass correlation coefficients (1, 2) for test-retest reliability ranged from 0.991 to 0.999. The Bland-Altman analysis results indicated no systematic error. [Conclusion] The results indicate that ultrasound measurements of interspinous process distance are highly reliable even when measured only once by a single person. PMID:27630399

  20. Absolute and relative reliability of lumbar interspinous process ultrasound imaging measurements.

    PubMed

    Tozawa, Ryosuke; Katoh, Munenori; Aramaki, Hidefumi; Kawasaki, Tsubasa; Nishikawa, Yuichi; Kumamoto, Tsuneo; Fujinawa, Osamu

    2016-08-01

    [Purpose] The intra- and inter-examiner reliabilities of lumbar interspinous process distances measured by ultrasound imaging were examined. [Subjects and Methods] The subjects were 10 males who had no history of orthopedic diseases or dysfunctions. Ten lumbar interspinous images from 360 images captured from 10 subjects were selected. The 10 images were measured by nine examiners. The lumbar interspinous process distance measurements were performed five times by each examiner. In addition, four of the nine examiners measured the distances again after 4 days for test-retest analysis. In statistical analysis, the intraclass correlation coefficient was used to investigate relative reliability, and Bland-Altman analysis was used to investigate absolute reliability. [Results] The intraclass correlation coefficients (1, 1) for intra-examiner reliability ranged from 0.985 to 0.998. For inter-rater reliability, the intraclass correlation coefficient (2, 1) was 0.969. The intraclass correlation coefficients (1, 2) for test-retest reliability ranged from 0.991 to 0.999. The Bland-Altman analysis results indicated no systematic error. [Conclusion] The results indicate that ultrasound measurements of interspinous process distance are highly reliable even when measured only once by a single person.

  1. Measurement of the Absolute Branching Fraction of D0 to K- pi+

    SciTech Connect

    Aubert, B.; Bona, M.; Boutigny, D.; Karyotakis, Y.; Lees, J.P.; Poireau, V.; Prudent, X.; Tisserand, V.; Zghiche, A.; Garra Tico, J.; Grauges, E.; Lopez, L.; Palano, A.; Eigen, G.; Ofte, I.; Stugu, B.; Sun, L.; Abrams, G.S.; Battaglia, M.; Brown, D.N.; Button-Shafer, J.; /LBL, Berkeley /Birmingham U. /Ruhr U., Bochum /Bristol U. /British Columbia U. /Brunel U. /Novosibirsk, IYF /UC, Irvine /UCLA /UC, Riverside /UC, San Diego /UC, Santa Barbara /UC, Santa Cruz /Caltech /Cincinnati U. /Colorado U. /Colorado State U. /Dortmund U. /Munich, Tech. U. /Ecole Polytechnique /Edinburgh U. /Ferrara U. /Frascati /Genoa U. /Harvard U. /Heidelberg U. /Imperial Coll., London /Iowa U. /Iowa State U. /Johns Hopkins U. /Karlsruhe U. /Orsay, LAL /LLNL, Livermore /Liverpool U. /Queen Mary, U. of London /Royal Holloway, U. of London /Louisville U. /Manchester U. /Maryland U. /Massachusetts U., Amherst /MIT, LNS /McGill U. /Maryland U. /INFN, Milan /Mississippi U. /Montreal U. /Mt. Holyoke Coll. /Naples U. /NIKHEF, Amsterdam /Notre Dame U. /Ohio State U. /Oregon U. /Padua U. /Paris U., VI-VII /Pennsylvania U. /Perugia U. /Pisa U. /Prairie View A-M /Princeton U. /INFN, Rome /Rostock U. /Rutherford /DSM, DAPNIA, Saclay /South Carolina U. /SLAC /Stanford U., Phys. Dept. /SUNY, Albany /Tennessee U. /Texas U. /Texas U., Dallas /Turin U. /Trieste U. /Valencia U., IFIC /Victoria U. /Warwick U. /Wisconsin U., Madison /Yale U.

    2007-04-25

    The authors measure the absolute branching fraction for D{sup 0} {yields} K{sup -} {pi}{sup +} using partial reconstruction of {bar B}{sup 0} {yields} D*{sup +}X{ell}{sup -}{bar {nu}}{sub {ell}} decays, in which only the charged lepton and the pion from the decay D*{sup +} {yields} D{sup 0}{pi}{sup +} are used. Based on a data sample of 230 million B{bar B} pairs collected at the {Upsilon}(4S) resonance with the BABAR detector at the PEP-II asymmetric-energy B Factory at SLAC, they obtain {Beta}(D{sup 0} {yields} K{sup -}{pi}{sup +}) = (4.007 {+-} 0.037 {+-} 0.070)%, where the first error is statistical and the second error is systematic.

  2. Absolute Measurement of Hadronic Branching Fractions of the D{sub s}{sup +} Meson

    SciTech Connect

    Alexander, J. P.; Berkelman, K.; Cassel, D. G.; Duboscq, J. E.; Ehrlich, R.; Fields, L.; Gibbons, L.; Gray, R.; Gray, S. W.; Hartill, D. L.; Heltsley, B. K.; Hertz, D.; Jones, C. D.; Kandaswamy, J.; Kreinick, D. L.; Kuznetsov, V. E.; Mahlke-Krueger, H.; Mohapatra, D.; Onyisi, P. U. E.; Patterson, J. R.

    2008-04-25

    The branching fractions of D{sub s}{sup {+-}} meson decays serve to normalize many measurements of processes involving charm quarks. Using 298 pb{sup -1} of e{sup +}e{sup -} collisions recorded at a center of mass energy of 4.17 GeV, we determine absolute branching fractions for eight D{sub s}{sup {+-}} decays with a double tag technique. In particular we determine the branching fraction B(D{sub s}{sup +}{yields}K{sup -}K{sup +}{pi}{sup +})=(5.50{+-}0.23{+-}0.16)%, where the uncertainties are statistical and systematic, respectively. We also provide partial branching fractions for kinematic subsets of the K{sup -}K{sup +}{pi}{sup +} decay mode.

  3. Absolute molecular transition frequencies measured by three cavity-enhanced spectroscopy techniques

    NASA Astrophysics Data System (ADS)

    Cygan, A.; Wójtewicz, S.; Kowzan, G.; Zaborowski, M.; Wcisło, P.; Nawrocki, J.; Krehlik, P.; Śliwczyński, Ł.; Lipiński, M.; Masłowski, P.; Ciuryło, R.; Lisak, D.

    2016-06-01

    Absolute frequencies of unperturbed 12C16O transitions from the near-infrared (3-0) band were measured with uncertainties five-fold lower than previously available data. The frequency axis of spectra was linked to the primary frequency standard. Three different cavity enhanced absorption and dispersion spectroscopic methods and various approaches to data analysis were used to estimate potential systematic instrumental errors. Except for a well established frequency-stabilized cavity ring-down spectroscopy, we applied the cavity mode-width spectroscopy and the one-dimensional cavity mode-dispersion spectroscopy for measurement of absorption and dispersion spectra, respectively. We demonstrated the highest quality of the dispersion line shape measured in optical spectroscopy so far. We obtained line positions of the Doppler-broadened R24 and R28 transitions with relative uncertainties at the level of 10-10. The pressure shifting coefficients were measured and the influence of the line asymmetry on unperturbed line positions was analyzed. Our dispersion spectra are the first demonstration of molecular spectroscopy with both axes of the spectra directly linked to the primary frequency standard, which is particularly desirable for the future reference-grade measurements of molecular spectra.

  4. An Absolute Index (Ab-index) to Measure a Researcher’s Useful Contributions and Productivity

    PubMed Central

    Biswal, Akshaya Kumar

    2013-01-01

    Bibliographic analysis has been a very powerful tool in evaluating the effective contributions of a researcher and determining his/her future research potential. The lack of an absolute quantification of the author’s scientific contributions by the existing measurement system hampers the decision-making process. In this paper, a new metric system, Absolute index (Ab-index), has been proposed that allows a more objective comparison of the contributions of a researcher. The Ab-index takes into account the impact of research findings while keeping in mind the physical and intellectual contributions of the author(s) in accomplishing the task. The Ab-index and h-index were calculated for 10 highly cited geneticists and molecular biologist and 10 young researchers of biological sciences and compared for their relationship to the researchers input as a primary author. This is the first report of a measuring method clarifying the contributions of the first author, corresponding author, and other co-authors and the sharing of credit in a logical ratio. A java application has been developed for the easy calculation of the Ab-index. It can be used as a yardstick for comparing the credibility of different scientists competing for the same resources while the Productivity index (Pr-index), which is the rate of change in the Ab-index per year, can be used for comparing scientists of different age groups. The Ab-index has clear advantage over other popular metric systems in comparing scientific credibility of young scientists. The sum of the Ab-indices earned by individual researchers of an institute per year can be referred to as Pr-index of the institute. PMID:24391941

  5. Absolute intensity calibration of flat-field space-resolved extreme ultraviolet spectrometer using radial profiles of visible and extreme ultraviolet bremsstrahlung continuum emitted from high-density plasmas in Large Helical Device

    SciTech Connect

    Dong Chunfeng; Wang Erhui; Morita, Shigeru; Goto, Motoshi

    2011-11-15

    A precise absolute intensity calibration of a flat-field space-resolved extreme ultraviolet (EUV) spectrometer working in wavelength range of 60-400 A is carried out using a new calibration technique based on radial profile measurement of the bremsstrahlung continuum in Large Helical Device. A peaked vertical profile of the EUV bremsstrahlung continuum has been successfully observed in high-density plasmas (n{sub e}{>=} 10{sup 14} cm{sup -3}) with hydrogen ice pellet injection. The absolute calibration can be done by comparing the EUV bremsstrahlung profile with the visible bremsstrahlung profile of which the absolute value has been already calibrated using a standard lamp. The line-integrated profile of measured visible bremsstrahlung continuum is firstly converted into the local emissivity profile by considering a magnetic surface distortion due to the plasma pressure, and the local emissivity profile of EUV bremsstrahlung is secondly calculated by taking into account the electron temperature profile and free-free gaunt factor. The line-integrated profile of the EUV bremsstrahlung continuum is finally calculated from the local emissivity profile in order to compare with measured EUV bremsstrahlung profile. The absolute intensity calibration can be done by comparing measured and calculated EUV bremsstrahlung profiles. The calibration factor is thus obtained as a function of wavelength with excellent accuracy. It is also found in the profile analysis that the grating reflectivity of EUV emissions is constant along the direction perpendicular to the wavelength dispersion. Uncertainties on the calibration factor determined with the present method are discussed including charge-coupled device operation modes.

  6. On the measurement of relative and absolute income-related health inequality.

    PubMed

    Clarke, Philip M; Gerdtham, Ulf-G; Johannesson, Magnus; Bingefors, Kerstin; Smith, Len

    2002-12-01

    In recent work on international comparisons of income-related inequalities in health, the concentration index has been used as a measure of health inequality. A drawback of this measure is that it is sensitive to whether it is estimated with respect to health or morbidity. An alternative would be to use the generalized concentration index that is based on absolute rather than relative health differences. In this methodological paper, we explore the importance of the choice of health inequality measure by comparing the income-related inequality in health status and morbidity between Sweden and Australia. This involves estimating a concentration index and a generalized concentration index for the eight-scale health profile of the Short Form 36 (SF-36) health survey. We then transform the scores for each scale into a measure of morbidity and show that whether the concentration index is estimated with respect to health or morbidity has an impact on the results. The ranking between the two countries is reversed for two of the eight dimensions of SF-36 and within both countries the ranking across the eight SF-36 scales is also affected. However, this change in ranking does not occur when the generalized concentration index is compared and we conclude with the implications of these results for reporting comparisons of income-related health inequality in different populations.

  7. Measurements of Absolute Hadronic Branching Fractions of the Λ_{c}^{+} Baryon.

    PubMed

    Ablikim, M; Achasov, M N; Ai, X C; Albayrak, O; Albrecht, M; Ambrose, D J; Amoroso, A; An, F F; An, Q; Bai, J Z; Baldini Ferroli, R; Ban, Y; Bennett, D W; Bennett, J V; Bertani, M; Bettoni, D; Bian, J M; Bianchi, F; Boger, E; Boyko, I; Briere, R A; Cai, H; Cai, X; Cakir, O; Calcaterra, A; Cao, G F; Cetin, S A; Chang, J F; Chelkov, G; Chen, G; Chen, H S; Chen, H Y; Chen, J C; Chen, M L; Chen, S J; Chen, X; Chen, X R; Chen, Y B; Cheng, H P; Chu, X K; Cibinetto, G; Dai, H L; Dai, J P; Dbeyssi, A; Dedovich, D; Deng, Z Y; Denig, A; Denysenko, I; Destefanis, M; De Mori, F; Ding, Y; Dong, C; Dong, J; Dong, L Y; Dong, M Y; Dou, Z L; Du, S X; Duan, P F; Eren, E E; Fan, J Z; Fang, J; Fang, S S; Fang, X; Fang, Y; Farinelli, R; Fava, L; Fedorov, O; Feldbauer, F; Felici, G; Feng, C Q; Fioravanti, E; Fritsch, M; Fu, C D; Gao, Q; Gao, X L; Gao, X Y; Gao, Y; Gao, Z; Garzia, I; Goetzen, K; Gong, L; Gong, W X; Gradl, W; Greco, M; Gu, M H; Gu, Y T; Guan, Y H; Guo, A Q; Guo, L B; Guo, Y; Guo, Y P; Haddadi, Z; Hafner, A; Han, S; Hao, X Q; Harris, F A; He, K L; Held, T; Heng, Y K; Hou, Z L; Hu, C; Hu, H M; Hu, J F; Hu, T; Hu, Y; Huang, G S; Huang, J S; Huang, X T; Huang, Y; Hussain, T; Ji, Q; Ji, Q P; Ji, X B; Ji, X L; Jiang, L W; Jiang, X S; Jiang, X Y; Jiao, J B; Jiao, Z; Jin, D P; Jin, S; Johansson, T; Julin, A; Kalantar-Nayestanaki, N; Kang, X L; Kang, X S; Kavatsyuk, M; Ke, B C; Kiese, P; Kliemt, R; Kloss, B; Kolcu, O B; Kopf, B; Kornicer, M; Kuehn, W; Kupsc, A; Lange, J S; Lara, M; Larin, P; Leng, C; Li, C; Li, Cheng; Li, D M; Li, F; Li, F Y; Li, G; Li, H B; Li, J C; Li, Jin; Li, K; Li, K; Li, Lei; Li, P R; Li, Q Y; Li, T; Li, W D; Li, W G; Li, X L; Li, X M; Li, X N; Li, X Q; Li, Z B; Liang, H; Liang, Y F; Liang, Y T; Liao, G R; Lin, D X; Liu, B J; Liu, C X; Liu, D; Liu, F H; Liu, Fang; Liu, Feng; Liu, H B; Liu, H H; Liu, H H; Liu, H M; Liu, J; Liu, J B; Liu, J P; Liu, J Y; Liu, K; Liu, K Y; Liu, L D; Liu, P L; Liu, Q; Liu, S B; Liu, X; Liu, Y B; Liu, Z A; Liu, Zhiqing; Loehner, H; Lou, X C; Lu, H J; Lu, J G; Lu, Y; Lu, Y P; Luo, C L; Luo, M X; Luo, T; Luo, X L; Lyu, X R; Ma, F C; Ma, H L; Ma, L L; Ma, Q M; Ma, T; Ma, X N; Ma, X Y; Ma, Y M; Maas, F E; Maggiora, M; Mao, Y J; Mao, Z P; Marcello, S; Messchendorp, J G; Min, J; Mitchell, R E; Mo, X H; Mo, Y J; Morales Morales, C; Muchnoi, N Yu; Muramatsu, H; Nefedov, Y; Nerling, F; Nikolaev, I B; Ning, Z; Nisar, S; Niu, S L; Niu, X Y; Olsen, S L; Ouyang, Q; Pacetti, S; Pan, Y; Patteri, P; Pelizaeus, M; Peng, H P; Peters, K; Pettersson, J; Ping, J L; Ping, R G; Poling, R; Prasad, V; Qi, H R; Qi, M; Qian, S; Qiao, C F; Qin, L Q; Qin, N; Qin, X S; Qin, Z H; Qiu, J F; Rashid, K H; Redmer, C F; Ripka, M; Rong, G; Rosner, Ch; Ruan, X D; Santoro, V; Sarantsev, A; Savrié, M; Schoenning, K; Schumann, S; Shan, W; Shao, M; Shen, C P; Shen, P X; Shen, X Y; Sheng, H Y; Song, W M; Song, X Y; Sosio, S; Spataro, S; Sun, G X; Sun, J F; Sun, S S; Sun, Y J; Sun, Y Z; Sun, Z J; Sun, Z T; Tang, C J; Tang, X; Tapan, I; Thorndike, E H; Tiemens, M; Ullrich, M; Uman, I; Varner, G S; Wang, B; Wang, B L; Wang, D; Wang, D Y; Wang, K; Wang, L L; Wang, L S; Wang, M; Wang, P; Wang, P L; Wang, S G; Wang, W; Wang, W P; Wang, X F; Wang, Y D; Wang, Y F; Wang, Y Q; Wang, Z; Wang, Z G; Wang, Z H; Wang, Z Y; Weber, T; Wei, D H; Wei, J B; Weidenkaff, P; Wen, S P; Wiedner, U; Wolke, M; Wu, L H; Wu, Z; Xia, L; Xia, L G; Xia, Y; Xiao, D; Xiao, H; Xiao, Z J; Xie, Y G; Xiu, Q L; Xu, G F; Xu, L; Xu, Q J; Xu, Q N; Xu, X P; Yan, L; Yan, W B; Yan, W C; Yan, Y H; Yang, H J; Yang, H X; Yang, L; Yang, Y X; Ye, M; Ye, M H; Yin, J H; Yu, B X; Yu, C X; Yu, J S; Yuan, C Z; Yuan, W L; Yuan, Y; Yuncu, A; Zafar, A A; Zallo, A; Zeng, Y; Zeng, Z; Zhang, B X; Zhang, B Y; Zhang, C; Zhang, C C; Zhang, D H; Zhang, H H; Zhang, H Y; Zhang, J J; Zhang, J L; Zhang, J Q; Zhang, J W; Zhang, J Y; Zhang, J Z; Zhang, K; Zhang, L; Zhang, X Y; Zhang, Y; Zhang, Y H; Zhang, Y N; Zhang, Y T; Zhang, Yu; Zhang, Z H; Zhang, Z P; Zhang, Z Y; Zhao, G; Zhao, J W; Zhao, J Y; Zhao, J Z; Zhao, Lei; Zhao, Ling; Zhao, M G; Zhao, Q; Zhao, Q W; Zhao, S J; Zhao, T C; Zhao, Y B; Zhao, Z G; Zhemchugov, A; Zheng, B; Zheng, J P; Zheng, W J; Zheng, Y H; Zhong, B; Zhou, L; Zhou, X; Zhou, X K; Zhou, X R; Zhou, X Y; Zhu, K; Zhu, K J; Zhu, S; Zhu, S H; Zhu, X L; Zhu, Y C; Zhu, Y S; Zhu, Z A; Zhuang, J; Zotti, L; Zou, B S; Zou, J H

    2016-02-01

    We report the first measurement of absolute hadronic branching fractions of Λ_{c}^{+} baryon at the Λ_{c}^{+}Λ[over ¯]_{c}^{-} production threshold, in the 30 years since the Λ_{c}^{+} discovery. In total, 12 Cabibbo-favored Λ_{c}^{+} hadronic decay modes are analyzed with a double-tag technique, based on a sample of 567  pb^{-1} of e^{+}e^{-} collisions at sqrt[s]=4.599  GeV recorded with the BESIII detector. A global least-squares fitter is utilized to improve the measured precision. Among the measurements for twelve Λ_{c}^{+} decay modes, the branching fraction for Λ_{c}^{+}→pK^{-}π^{+} is determined to be (5.84±0.27±0.23)%, where the first uncertainty is statistical and the second is systematic. In addition, the measurements of the branching fractions of the other 11 Cabibbo-favored hadronic decay modes are significantly improved. PMID:26894702

  8. A new way of measuring apoptosis by absolute quantitation of inter-nucleosomally fragmented genomic DNA

    PubMed Central

    Hooker, David J.; Mobarok, Masqura; Anderson, Jenny L.; Rajasuriar, Reena; Gray, Lachlan R.; Ellett, Anne M.; Lewin, Sharon R.; Gorry, Paul R.; Cherry, Catherine L.

    2012-01-01

    Several critical events of apoptosis occur in the cell nucleus, including inter-nucleosomal DNA fragmentation (apoptotic DNA) and eventual chromatin condensation. The generation of apoptotic DNA has become a biochemical hallmark of apoptosis because it is a late ‘point of no return’ step in both the extrinsic (cell-death receptor) and intrinsic (mitochondrial) apoptotic pathways. Despite investigators observing apoptotic DNA and understanding its decisive role as a marker of apoptosis for over 20 years, measuring it has proved elusive. We have integrated ligation-mediated PCR and qPCR to design a new way of measuring apoptosis, termed ApoqPCR, which generates an absolute value for the amount (picogram) of apoptotic DNA per cell population. ApoqPCR’s advances over current methods include a 1000-fold linear dynamic range yet sensitivity to distinguish subtle low-level changes, measurement with a 3- to 4-log improvement in sample economy, and capacity for archival or longitudinal studies combined with high-throughput capability. We demonstrate ApoqPCR’s utility in both in vitro and in vivo contexts. Considering the fundamental role apoptosis has in vertebrate and invertebrate health, growth and disease, the reliable measurement of apoptotic nucleic acid by ApoqPCR will be of value in cell biology studies in basic and applied science. PMID:22544708

  9. Absolute calibration method for laser megajoule neutron yield measurement by activation diagnostics

    NASA Astrophysics Data System (ADS)

    Landoas, Olivier; Yu Glebov, Vladimir; Rossé, Bertrand; Briat, Michelle; Disdier, Laurent; Sangster, Thomas C.; Duffy, Tim; Marmouget, Jean Gabriel; Varignon, Cyril; Ledoux, Xavier; Caillaud, Tony; Thfoin, Isabelle; Bourgade, Jean-Luc

    2011-07-01

    The laser megajoule (LMJ) and the National Ignition Facility (NIF) plan to demonstrate thermonuclear ignition using inertial confinement fusion (ICF). The neutron yield is one of the most important parameters to characterize ICF experiment performance. For decades, the activation diagnostic was chosen as a reference at ICF facilities and is now planned to be the first nuclear diagnostic on LMJ, measuring both 2.45 MeV and 14.1 MeV neutron yields. Challenges for the activation diagnostic development are absolute calibration, accuracy, range requirement, and harsh environment. At this time, copper and zirconium material are identified for 14.1 MeV neutron yield measurement and indium material for 2.45 MeV neutrons. A series of calibrations were performed at Commissariat à l'Energie Atomique (CEA) on a Van de Graff facility to determine activation diagnostics efficiencies and to compare them with results from calculations. The CEA copper activation diagnostic was tested on the OMEGA facility during DT implosion. Experiments showed that CEA and Laboratory for Laser Energetics (LLE) diagnostics agree to better than 1% on the neutron yield measurement, with an independent calibration for each system. Also, experimental sensitivities are in good agreement with simulations and allow us to scale activation diagnostics for the LMJ measurement range.

  10. Tunable diode laser measurements of absolute line strengths in the 2nu2 band of N2O near 8 microns

    NASA Technical Reports Server (NTRS)

    Tang, Lai-Wa; Daunt, Stephen J.; Nadler, Shachar

    1989-01-01

    The absolute intensities of five rotational transitions in the 2nu2 band of N2O near 8 microns have been measured with a tunable-diode laser-spectrometer. Measurements were reproducible within an average deviation of about 3 percent, and the experimental and calculated line strengths differed by only 1.5 percent. An analysis of the line strengths has yielded a band strength of S(v) = 6.98 + or - 0.26/sq cm per atm at 296 K. The band and line strengths are in excellent agreement with two recently reported values obtained by using Fourier transform-IR spectroscopy.

  11. Optical measurement of absolute flatness with the deflectometric measurement systems at PTB

    NASA Astrophysics Data System (ADS)

    Ehret, Gerd; Schulz, Michael; Baier, Maik; Fitzenreiter, Arne

    2013-03-01

    Highly accurate flatness measurements are needed for synchrotron optics, optical flats, or optical mirrors. Recently, two new scanning deflectometric flatness measurement systems have been installed at the Physikalisch-Technische Bundesanstalt (PTB). The two systems (one system for horizontal and the other for vertical specimens) can measure specimens with sizes up to one metre with an expected uncertainty in the sub-nanometre range. In addition to the classical deflectometric procedure, also the 'extended shear angle difference (ESAD)' and the 'exact autocollimation deflectometric scanning (EADS)' procedures are implemented. The lateral resolution of scanning deflectometric techniques is limited by the aperture of the angle measurement system, usually an autocollimator with typical apertures of a few millimetres. With the EADS procedure, the specimen is scanned with an angular null instrument which has the potential to improve the lateral resolution down to the sub-millimetre region. A new concept and design of an appropriate angular null instrument are presented and discussed.

  12. The impact of water temperature on the measurement of absolute dose

    NASA Astrophysics Data System (ADS)

    Islam, Naveed Mehdi

    To standardize reference dosimetry in radiation therapy, Task Group 51 (TG 51) of American Association of Physicist's in Medicine (AAPM) recommends that dose calibration measurements be made in a water tank at a depth of 10 cm and at a reference geometry. Methodologies are provided for calculating various correction factors to be applied in calculating the absolute dose. However the protocol does not specify the water temperature to be used. In practice, the temperature of water during dosimetry may vary considerably between independent sessions and different centers. In this work the effect of water temperature on absolute dosimetry has been investigated. Density of water varies with temperature, which in turn may impact the beam attenuation and scatter properties. Furthermore, due to thermal expansion or contraction air volume inside the chamber may change. All of these effects can result in a change in the measurement. Dosimetric measurements were made using a Farmer type ion chamber on a Varian Linear Accelerator for 6 MV and 23 MV photon energies for temperatures ranging from 10 to 40 °C. A thermal insulation was designed for the water tank in order to maintain relatively stable temperature over the duration of the experiment. Dose measured at higher temperatures were found to be consistently higher by a very small magnitude. Although the differences in dose were less than the uncertainty in each measurement, a linear regression of the data suggests that the trend is statistically significant with p-values of 0.002 and 0.013 for 6 and 23 MV beams respectively. For a 10 degree difference in water phantom temperatures, which is a realistic deviation across clinics, the final calculated reference dose can differ by 0.24% or more. To address this effect, first a reference temperature (e.g.22 °C) can be set as the standard; subsequently a correction factor can be implemented for deviations from this reference. Such a correction factor is expected to be of similar

  13. Reservoir properties inversion in a karst aquifer using absolute gravity measurements

    NASA Astrophysics Data System (ADS)

    Sabrina, Deville; Thomas, Jacob; Jean, Chery; Roger, Bayer; Cedric, Champollion; Moigne Nicolas, Le

    2010-05-01

    Direct estimate of water storage and transfer in karst aquifers are difficult to obtain due to the extreme permeability variation of the medium. In this study, we aim to quantify water transfer properties in a karst aquifer of the Larzac plateau (South Massif Central, France) using absolute gravity monitoring. Our measurements are cutting edge as they directly measure the integrated water content below the gravimeter. We analyze monthly repeated FG5 absolute gravity measurements (1-2 microGal precision) over a three-year period at three sites on the karst aquifer. Important precipitation events lead to significant gravity increases which peak up to several weeks after the events depending on the site. Also, gravity decreases in a different manner at each site during drier periods. We consider the different gravity responses at each site to relate to water transfer properties between the surface and the unsaturated zone beneath. Within this scope, the gravity signal is used to invert for those water transfer properties. A simple two-tank reservoir model including a ‘soil' reservoir that feeds into a ‘subsurface' reservoir is used as the forward model in a Monte Carlo simulation. Reservoir discharge proceeds according to Maillet's law. Water levels within the reservoirs are converted into a gravity signal considering an infinite slab scaled by a factor that accounts for both the surrounding topographic effects and the water interception by the building where the measurements are made. Inverted parameters are the discharge constants and the scaling factors. Model input is rainfall measured with rain gauges at each site minus estimated evapotranspiration. The inversion leads to scaling factors much smaller than 1 for the attraction of the surface reservoir. The effects of the surrounding topography and those of the building on gravity are compared to the inversion result of the ‘surface reservoir' scaling factors. We discuss if the forward model and underlying

  14. The study of the nonlinear correction of the FMCW absolute distance measurement using frequency-sampling and precision analysis

    NASA Astrophysics Data System (ADS)

    Lu, Cheng; Gan, Yu; Chen, Fengdong; Liu, Bingguo; Zhuang, Zhitao; Xu, Xinke; Liu, Guodong

    2014-12-01

    This article uses the external cavity laser to realize FMCW high precision absolute distance measurement, as the external cavity laser owns the advantage of large tuning range of frequency. Firstly, aim at the problem of nonlinear tuning of the external cavity laser, a study of method of frequency-sampling has been shown. Secondly, in this article the mathematical model of the absolute dis tance measurement system has been established, and the sources of the errors of the FMCW absolute distance measurement has been analyzed, and the accuracy model has been established. Finally, a ball which is put at a distance about 3 meters is measured, and the random error is 0.3479μm, the standard uncertainty of measurement system is 0.3479μm+3.141Rppm.

  15. ^241Am(n,γ) absolute cross sections measured with DANCE

    NASA Astrophysics Data System (ADS)

    Jandel, M.; Bredeweg, T. A.; Fowler, M. M.; Bond, E. M.; Chadwick, M. B.; Clement, R. R.; Couture, A.; O'Donnell, J. M.; Reifarth, R.; Rundberg, R. S.; Ullmann, J. L.; Vieira, D. J.; Wilhelmy, J. B.; Wouters, J. M.; Agvaanluvsan, U.; Macri, R. A.; Sheets, S. A.; Wu, C. Y.; Becker, J. A.

    2007-10-01

    ^241Am is present in plutonium due to the beta decay of ^241Pu (t1/2=14.38 years). As such ^241Am can be used as a detector for nuclear forensics. A precise measurement of ^241Am(n,γ) cross section is thus needed for this application. The measurement is also of interest for advanced reactor design as part of the Global Nuclear Energy Partnership (GNEP). The Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL) was used for neutron capture cross section measurement on ^241Am. The high granularity of DANCE (160 BaF2 detectors in a 4π geometry) enables the efficient detection of prompt gamma-rays following a neutron capture. DANCE is located on the 20.26 m neutron flight path 14(FP14) at the Manuel Lujan Jr. Neutron Scattering Center at the Los Alamos Neutron Science Center (LANSCE). The absolute ^241Am(n,γ) cross sections were obtained in the range of neutron energies from 0.02 eV to 320 keV. The results will be compared to existing evaluations in detail.

  16. Femtosecond frequency comb measurement of absolute frequencies and hyperfine coupling constants in cesium vapor

    SciTech Connect

    Stalnaker, Jason E.; Mbele, Vela; Gerginov, Vladislav; Fortier, Tara M.; Diddams, Scott A.; Hollberg, Leo; Tanner, Carol E.

    2010-04-15

    We report measurements of absolute transition frequencies and hyperfine coupling constants for the 8S{sub 1/2}, 9S{sub 1/2}, 7D{sub 3/2}, and 7D{sub 5/2} states in {sup 133}Cs vapor. The stepwise excitation through either the 6P{sub 1/2} or 6P{sub 3/2} intermediate state is performed directly with broadband laser light from a stabilized femtosecond laser optical-frequency comb. The laser beam is split, counterpropagated, and focused into a room-temperature Cs vapor cell. The repetition rate of the frequency comb is scanned and we detect the fluorescence on the 7P{sub 1/2,3/2{yields}}6S{sub 1/2} branches of the decay of the excited states. The excitations to the different states are isolated by the introduction of narrow-bandwidth interference filters in the laser beam paths. Using a nonlinear least-squares method we find measurements of transition frequencies and hyperfine coupling constants that are in agreement with other recent measurements for the 8S state and provide improvement by 2 orders of magnitude over previously published results for the 9S and 7D states.

  17. Absolute measurement of the effective nonlinearities of KTP and BBO crystals by optical parametric amplification.

    PubMed

    Armstrong, D J; Alford, W J; Raymond, T D; Smith, A V

    1996-04-20

    Absolute magnitudes of the effective nonlinearity, deff, were measured for seven KTP and six BBO crystals. The d(eff), were derived from the parametric gain of an 800-nm signal wave in the sample crystals when they were pumped by the frequency-doubled, spatially filtered light from an injectionseeded, Q-switched Nd:YAG laser. The KTP crystals, all type II phase matched with propagation in the X-Z plane, had d(eff) values ranging from 1.97 to 3.50 pm/V. Measurements of gain as a function of phase velocity mismatch indicate that two of the KTP crystals clearly contain multiple ferroelectric domains. For five type I phase-matched BBO crystals, d(eff) ranged from 1.76 to 1.83 pm/V, and a single type II phase-matched BBO crystal had a d(eff) of 1.56 pm/V. The uncertainty in our measurements of d(eff) values is ±5% for KTP and ±10% for BBO.

  18. Study on improving the turbidity measurement of the absolute coagulation rate constant.

    PubMed

    Sun, Zhiwei; Liu, Jie; Xu, Shenghua

    2006-05-23

    The existing theories dealing with the evaluation of the absolute coagulation rate constant by turbidity measurement were experimentally tested for different particle-sized (radius = a) suspensions at incident wavelengths (lambda) ranging from near-infrared to ultraviolet light. When the size parameter alpha = 2pi a/lambda > 3, the rate constant data from previous theories for fixed-sized particles show significant inconsistencies at different light wavelengths. We attribute this problem to the imperfection of these theories in describing the light scattering from doublets through their evaluation of the extinction cross section. The evaluations of the rate constants by all previous theories become untenable as the size parameter increases and therefore hampers the applicable range of the turbidity measurement. By using the T-matrix method, we present a robust solution for evaluating the extinction cross section of doublets formed in the aggregation. Our experiments show that this new approach is effective in extending the applicability range of the turbidity methodology and increasing measurement accuracy.

  19. Impedance probe with phase and gain detection for absolute electron density measurements

    NASA Astrophysics Data System (ADS)

    Steigies, C. T.; Pfaff, R. F.

    2003-04-01

    A new impedance probe to accurately measure plasma density using a variety of phase detection schemes has been designed for use on a sounding rocket. The instrument uses a Direct Digital Synthesis (DDS) chip to generate a frequency sweep of 256 discrete frequencies between 100 kHz and 5 MHz of a duration of 1 ms each, which generally covers the expected range of plasma frequencies. The voltage and current transmitted by a short dipole antenna, as well as the voltage received by a second receiving dipole antenna spaced 1 m away, are sampled in snippets with a 14-bit A/D converter at 8 MHz and telemetered to the ground. This mode of the instrument uses most of the 8 Mbits telemetry which is available for the impedance probe. A second, low-telemetry mode measures phase and gain between transmitted voltage and transmitted current, as well as between transmitted voltage and received voltage. For this measurement, two different circuits are provided. A phase/gain meter IC determines phase and gain between two signals. In addition, a second DDS synthesizes a frequency a few kHz below the sweep frequency. This signal is mixed with the transmitted voltage and current, as well as the received voltage. The mixed signals are sampled at a lower rate and sent to the ground. Comparing the signals with the mixed signal of the transmitted voltage allows the determination of phase and gain of both the transmitted current and the received voltage. As this is carried out as a function of frequency, the parallel resonance at the upper hybrid frequency will be discerned, from which the plasma density may be easily calculated. The instrument will be flown on a NASA sounding rocket from Poker Flat, Alaska in February, 2003. Data showing the performance of the instrument will be presented. The absolute electron density measurements made by this instrument will be used to cross calibrate with simultaneous Langmuir probe measurements.

  20. In-Flight Measurement of the Absolute Energy Scale of the Fermi Large Area Telescope

    SciTech Connect

    Ackermann, M.; Ajello, M.; Allafort, A.; Atwood, W.B.; Axelsson, M.; Baldini, L.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Bloom, E.D.; Bonamente, E.; Borgland, A.W.; Bouvier, A.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Buehler, R.; Buson, S.; /more authors..

    2012-09-20

    The Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope is a pair-conversion telescope designed to survey the gamma-ray sky from 20 MeV to several hundreds of GeV. In this energy band there are no astronomical sources with sufficiently well known and sharp spectral features to allow an absolute calibration of the LAT energy scale. However, the geomagnetic cutoff in the cosmic ray electron-plus-positron (CRE) spectrum in low Earth orbit does provide such a spectral feature. The energy and spectral shape of this cutoff can be calculated with the aid of a numerical code tracing charged particles in the Earth's magnetic field. By comparing the cutoff value with that measured by the LAT in different geomagnetic positions, we have obtained several calibration points between {approx}6 and {approx}13 GeV with an estimated uncertainty of {approx}2%. An energy calibration with such high accuracy reduces the systematic uncertainty in LAT measurements of, for example, the spectral cutoff in the emission from gamma ray pulsars.

  1. In-Flight Measurement of the Absolute Energy Scale of the Fermi Large Area Telescope

    NASA Technical Reports Server (NTRS)

    Ackermann, M.; Ajello, M.; Allafort, A.; Atwood, W. B.; Axelsson, M.; Baldini, L.; Barbielini, G; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B,; Bloom, E. D.; Bonamente, E.; Borgland, A. W.; Bouvier, A.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Buehler, R.; Gehrels, N.; Hays, E.; McEnery, J. E.; Thompson, D. J.; Troja, E. J.

    2012-01-01

    The Large Area Telescope (LAT) on-board the Fermi Gamma-ray Space Telescope is a pair-conversion telescope designed to survey the gamma-ray sky from 20 MeV to several hundreds of GeV. In this energy band there are no astronomical sources with sufficiently well known and sharp spectral features to allow an absolute calibration of the LAT energy scale. However, the geomagnetic cutoff in the cosmic ray electron- plus-positron (CRE) spectrum in low Earth orbit does provide such a spectral feature. The energy and spectral shape of this cutoff can be calculated with the aid of a numerical code tracing charged particles in the Earth's magnetic field. By comparing the cutoff value with that measured by the LAT in different geomagnetic positions, we have obtained several calibration points between approx. 6 and approx. 13 GeV with an estimated uncertainty of approx. 2%. An energy calibration with such high accuracy reduces the systematic uncertainty in LAT measurements of, for example, the spectral cutoff in the emission from gamma ray pulsars.

  2. Investigating 2010 Northern Cascadia ETS Processes With Absolute Gravity & Deformation Measurements Near Port Renfrew, British Columbia

    NASA Astrophysics Data System (ADS)

    Henton, J. A.; Dragert, H.; Wang, K.; Kao, H.; Lambert, A.

    2010-12-01

    The monitoring of subduction zone Episodic Tremor and Slip (ETS) has been carried out primarily using seismic data for tremor and continuous Global Positioning System (GPS) and strain- or tilt-meter observations for transient slip. The regularity of ETS episodes in the forearc of the northern Cascadia Subduction Zone has recently allowed us to schedule a series of absolute gravity (AG) measurements to augment these other data and thereby help in understanding the physical processes involved in the generation of ETS. High-precision AG observations are sensitive to vertical motion of the observation site as well as mass redistribution during transient deformation. For the 2010 ETS event in the northern Cascadia, AG observations were carried out at Port Renfrew, British Columbia. The Port Renfrew region was targeted since it has typically had large (~7mm) vertical displacements measured at a nearby GPS site. Additionally this region has experienced large strains during past ETS episodes. The closest PBO borehole strainmeter to Port Renfrew, B004 (Sekiu, WA), typically experiences ETS shear strain transients exceeding 100 nanostrain. In this contribution, we focus on the analysis of the multiple epoch series of AG observations at Port Renfrew during the 2010 ETS event. The ratio of the change of surface gravity (Δg) to vertical displacement (Δh) during the ETS event will also be examined. This ratio provides unique constraints on processes involved in generating observed gravity signals and will help us explore the mechanism of ETS.

  3. Measurement of the Absolute Branching Fractions for $D^-_s\\!\\rightarrow\\!\\ell^-\\bar{\

    SciTech Connect

    del Amo Sanchez, P.; Lees, J.P.; Poireau, V.; Prencipe, E.; Tisserand, V.; Garra Tico, J.; Grauges, E.; Martinelli, M.; Palano, A.; Pappagallo, M.; Eigen, G.; Stugu, B.; Sun, L.; Battaglia, M.; Brown, David Nathan; Hooberman, B.; Kerth, L.T.; Kolomensky, Yu.G.; Lynch, G.; Osipenkov, I.L.; Tanabe, T.; /more authors..

    2010-10-27

    The absolute branching fractions for the decays D{sub s}{sup -} {yields} {ell}{sup -}{bar {nu}}{sub {ell}} ({ell} = e, {mu}, or {tau}) are measured using a data sample corresponding to an integrated luminosity of 521 fb{sup -1} collected at center of mass energies near 10.58 GeV with the BABAR detector at the PEP-II e{sup +}e{sup -} collider at SLAC. The number of D{sub s}{sup -} mesons is determined by reconstructing the recoiling system DKX{gamma} in events of the type e{sup +}e{sup -}DKXD*{sub s}{sup -}, where D*{sub s}{sup -} {yields} D{sub s}{sup -}{gamma} and X represents additional pions from fragmentation. The D{sub s}{sup -} {yields} {ell}{sup 0}{nu}{sub {ell}} events are detected by full or partial reconstruction of the recoiling system DKX{gamma}{ell}. The branching fraction measurements are combined to determine the D{sub s}{sup -} decay constant f{sub D{sub s}} = (258.6 {+-} 6.4 {+-} 7.5) MeV, where the first uncertainty is statistical and the second is systematic.

  4. Crystalline sulfur dioxide: Crystal field splittings, absolute band intensities and complex refractive indices derived from infrared spectra

    NASA Technical Reports Server (NTRS)

    Khanna, R. K.; Zhao, Guizhi

    1986-01-01

    The infrared absorption spectra of thin crystalline films of sulfur dioxide at 90 K are reported in the 2700 to 450/cm region. The observed multiplicity of the spectral features in the regions of fundamentals is attributed to factor group splittings of the modes in a biaxial crystal lattice and the naturally present minor S-34, S-36, and O-18 isotopic species. Complex refractive indices determined by an iterative Kramers-Kronig analysis of the extinction data, and absolute band strengths derived from them, are also reported in this region.

  5. Absolute frequency measurement for the emission transitions of molecular iodine in the 982 - 985 nm range

    SciTech Connect

    Matyugin, Yu A; Ignatovich, S M; Kuznetsov, Sergei A; Nesterenko, M I; Okhapkin, M V; Pivtsov, V S; Skvortsov, Mikhail N; Bagaev, Sergei N

    2012-03-31

    We report high-precision frequency measurements of the separate hyperfine structure (HFS) components of the emission B - X system transitions of {sup 127}I{sub 2} molecules in the 982 - 985 nm range. To resolve the HFS of the emission lines, advantage was taken of the method of three-level laser spectroscopy. The function of exciting radiation was fulfilled by the second harmonic of a cw Nd : YAG laser, and the probe radiation in the 968 - 998 nm range was generated by an external-cavity diode laser. The output Nd : YAG laser frequency was locked to an HFS component of the absorption transition and the probing laser radiation to the emission transition component. When both frequencies were locked to HFS components with a common upper level, the output diode laser frequency was precisely equal to the emission transition frequency. The output frequency of the thus stabilised diode laser was measured with the help of a femtosecond optical frequency synthesiser based on a Ti : sapphire laser. We present the results of the absolute frequency measurements of 20 HFS components belonging to six vibrational - rotational transitions of the B - X system of iodine [R56(32 - 48)a1, P58(32 - 48)a1, P85(33 - 48)a1, R87(33 - 48a1, R88(33 - 48)a10] and all 15 components of the R86(33 - 48) line. The relative measurement uncertainty is equal to 7 Multiplication-Sign 10{sup -10} and is determined by the frequency instability of the diode laser radiation.

  6. The reaction H + C4H2 - Absolute rate constant measurement and implication for atmospheric modeling of Titan

    NASA Technical Reports Server (NTRS)

    Nava, D. F.; Mitchell, M. B.; Stief, L. J.

    1986-01-01

    The absolute rate constant for the reaction H + C4H2 has been measured over the temperature (T) interval 210-423 K, using the technique of flash photolysis-resonance fluorescence. At each of the five temperatures employed, the results were independent of variations in C4H2 concentration, total pressure of Ar or N2, and flash intensity (i.e., the initial H concentration). The rate constant, k, was found to be equal to 1.39 x 10 to the -10th exp (-1184/T) cu cm/s, with an error of one standard deviation. The Arrhenius parameters at the high pressure limit determined here for the H + C4H2 reaction are consistent with those for the corresponding reactions of H with C2H2 and C3H4. Implications of the kinetic carbon chemistry results, particularly those at low temperature, are considered for models of the atmospheric carbon chemistry of Titan. The rate of this reaction, relative to that of the analogous, but slower, reaction of H + C2H2, appears to make H + C4H2 a very feasible reaction pathway for effective conversion of H atoms to molecular hydrogen in the stratosphere of Titan.

  7. Measurement of Absolute Excitation Cross Sections in Highly-Charged Ions Using Electron Energy Loss and Merged Beams

    NASA Technical Reports Server (NTRS)

    Chutjian, A.; Smith, Steven J.; Lozano, J.

    2002-01-01

    There is increasing emphasis during this decade on understanding energy balance and phenomena observed in high electron temperature plasmas. The UV spectral return from FUSE, the X-ray spectral return from the HETG on Chandra and the LETGS 011 XMM-Newton are just beginning. Line emissions are almost entirely from highly-charged ions (HCIs) of C, N, 0, Ne, Mg, S, Si, Ca, and Fe. The Constellation-X mission will provide X-ray spectroscopy up to photon energies of 0.12 nm (10 keV) where primary line emitters will be HCIs. A variety of atomic parameters are required to model the stellar and solar plasma. These include cross sections for excitation, ionization, charge-exchange, X-ray emission, direct and indirect recombination, lifetimes and branching ratios, and dependences on l, m mixing by external E and B fields. In almost all cases the atomic quantities are calculated, and few comparisons to experiment have been carried out. Collision strengths and Einstein A-values are required to convert the observed spectral intensities to electron temperatures and densities in the stellar plasma. The JPL electron energy-loss and merged beam approach has been used to measure absolute collision strengths in a number of ions, with critical comparison made to the best available theories.

  8. Absolute Rovibrational Intensities, Self-Broadening and Self-Shift Coefficients for the X(sup 1) Sigma(+) V=3 (left arrow) V=0 Band (C-12)(O-16)

    NASA Technical Reports Server (NTRS)

    Chackerian, Charles, Jr.; Freedman, R.; Giver, L. P.; Brown, L. R.

    2001-01-01

    The rotationless transition moment squared for the x(sup 1) sigma (sup +) v=3 (left arrow) v=0 band of CO is measured to be the absolute value of R (sub 3-0) squared = 1.7127(25)x 10(exp -7) Debye squared. This value is about 8.6 percent smaller than the value assumed for HITRAN 2000. The Herman-Wallis intensity factor of this band is F=1+0.01168(11)m+0.0001065(79)m squared. The determination of self-broadening coefficients is improved with the inclusion of line narrowing; self-shifts are also reported.

  9. Improved Absolute Frequency Measurement of the 171Yb Optical Lattice Clock towards a Candidate for the Redefinition of the Second

    NASA Astrophysics Data System (ADS)

    Yasuda, Masami; Inaba, Hajime; Kohno, Takuya; Tanabe, Takehiko; Nakajima, Yoshiaki; Hosaka, Kazumoto; Akamatsu, Daisuke; Onae, Atsushi; Suzuyama, Tomonari; Amemiya, Masaki; Hong, Feng-Lei

    2012-10-01

    We demonstrate an improved absolute frequency measurement of the 1S0–3P0 clock transition at 578 nm in 171Yb atoms in a one-dimensional optical lattice. The clock laser linewidth is reduced to ≈2 Hz by phase-locking the laser to an ultrastable neodymium-doped yttrium aluminum garnet (Nd:YAG) laser at 1064 nm through an optical frequency comb with an intracavity electrooptic modulator to achieve a high servo bandwidth. The absolute frequency is determined as 518 295 836 590 863.1(2.0) Hz relative to the SI second, and will be reported to the International Committee for Weights and Measures.

  10. Measurement of the absolute Raman cross section of the optical phonon in silicon

    NASA Astrophysics Data System (ADS)

    Aggarwal, R. L.; Farrar, L. W.; Saikin, S. K.; Aspuru-Guzik, A.; Stopa, M.; Polla, D. L.

    2011-04-01

    The absolute Raman cross section σ of the first-order 519 cm -1 optical phonon in silicon was measured using a small temperature-controlled blackbody for the signal calibration of the Raman system. Measurements were made with a 25-mil thick (001) silicon sample located in the focal plane of a 20-mm effective focal length (EFL) lens using 785-, 1064-, and 1535-nm CW pump lasers for the excitation of Raman scattering. The pump beam was polarized along the [100] axis of the silicon sample. Values of 1.0±0.2×10 -27, 3.6±0.7×10 -28, and 1.1±0.2×10 -29 cm 2 were determined for σ for 785-, 1064-, and 1535-nm excitation, respectively. The corresponding values of the Raman scattering efficiency S are 4.0±0.8×10 -6, 1.4±0.3×10 -6, and 4.4±0.8×10 -8 cm -1 sr -1.The values of the Raman polarizability |d| for 785-, 1064-, and 1535-nm excitation are 4.4±0.4×10 -15, 5.1±0.5×10 -15, and 1.9±0.2×10 -15 cm 2, respectively. The values of 4.4±0.4×10 -15 and 5.1±0.5×10 -15 cm 2 for |d| for 785- and 1064-nm excitation, respectively, are 1.3 and 2.0 times larger than the values of 3.5×10 -15 and 2.5×10 -15 cm 2 calculated by Wendel. The Raman polarizability |d| computed using the density functional theory in the long-wavelength limit is consistent with the general trend of the measured data and Wendel's model.

  11. Absolute acceleration measurements on STS-50 from the Orbital Acceleration Research Experiment (OARE)

    NASA Technical Reports Server (NTRS)

    Blanchard, Robert C.; Nicholson, John Y.; Ritter, James R.

    1994-01-01

    Orbital Acceleration Research Experiment (OARE) data on Space Transportation System (STS)-50 have been examined in detail during a 2-day time period. Absolute acceleration levels have been derived at the OARE location, the orbiter center-of-gravity, and at the STS-50 spacelab Crystal Growth Facility. During the interval, the tri-axial OARE raw telemetered acceleration measurements have been filtered using a sliding trimmed mean filter in order to remove large acceleration spikes (e.g., thrusters) and reduce the noise. Twelve OARE measured biases in each acceleration channel during the 2-day interval have been analyzed and applied to the filtered data. Similarly, the in situ measured x-axis scale factors in the sensor's most sensitive range were also analyzed and applied to the data. Due to equipment problem(s) on this flight, both y- and z-axis sensitive range scale factors were determined in a separate process using orbiter maneuvers and subsequently applied to the data. All known significant low-frequency corrections at the OARE location (i.e., both vertical and horizontal gravity-gradient, and rotational effects) were removed from the filtered data in order to produce the acceleration components at the orbiter center-of-gravity, which are the aerodynamic signals along each body axis. Results indicate that there is a force being applied to the Orbiter in addition to the aerodynamic forces. The OARE instrument and all known gravitational and electromagnetic forces have been reexamined, but none produces the observed effect. Thus, it is tentatively concluded that the orbiter is creating the environment observed. At least part of this force is thought to be due to the Flash Evaporator System.

  12. Quantitative analysis in field-flow fractionation using ultraviolet-visible detectors: an experimental design for absolute measurements

    PubMed

    Zattoni; Melucci; Torsi; Reschiglian

    2000-03-01

    In previous works, it has been shown that a standard ultraviolet-visible detection system can be used for quantitative analysis of heterogeneous systems (dispersed supermicron particles) in field-flow fractionation (FFF) by single peak area measurements. Such an analysis method was shown to require either experimental measurements (standardless analysis) or an accurate model (absolute analysis) to determine the extinction efficiency of the particulate samples. In this work, an experimental design to assess absolute analysis in FFF through prediction of particles' optical extinction is presented. Prediction derives from the semiempirical approach by van de Hulst and Walstra. Special emphasis is given to the restriction of the experimental domain of instrumental conditions within which absolute analysis is allowed. Validation by statistical analysis and a practical application to real sample recovery studies are also given.

  13. An attempt to determine the absolute geomagnetic field intensity in Southwestern Iceland during the Gauss-Matuyama reversal

    NASA Astrophysics Data System (ADS)

    Goguitchaichvili, Avto; Prévot, Michel; Thompson, John; Roberts, Neil

    1999-08-01

    We have measured the variation in the intensity of the geomagnetic field during the Gauss-Matuyama (N4-R3) polarity reversal by application of the Thelliers' method to specimens of lava flows from Hvalfjördur district in Western Iceland (Reynivallahals Mts.). Eleven lava flows all show very similar directions corresponding to an equatorial VGP (Plat=2.9°N, Plong=81.9°E, A95=4.2, K=119). Twenty-nine specimens from nine of the flows were pre-selected for palaeointensity determination on the basis that specimens from the same drill cores showed a single component of magnetisation upon thermal or AF demagnetisation, and possessed low magnetic viscosity and reversible susceptibility curves upon heating at 600-650°C. Observation that the directional data obtained in the course of the palaeointensity experiments occasionally showed substantial non-linearity indicates that a significant chemical remanent magnetization (CRM) can be acquired in the direction of the laboratory field during heating at T. For each double heating step we calculated the ratio of CRM( T) to the magnitude of the natural remanent magnetization (NRM( T)) in the direction of characteristic remanence (obtained independently from another specimen from the same core). When this ratio exceeded 15%, the paleointensity data was rejected. In addition, specimens for which the quality factor was less than 5 were rejected. Twelve reliable palaeointensity values were obtained from specimens representing five lava flows. The results confirm that the palaeointensity was substantially reduced during the N4-R3 reversal. The range of mean palaeointensity values obtained for the five flows is 8.8 to 20.5 and the overall mean is 14.8±4.6 μT. This corresponds to an equivalent VDM of 3.81±1.19 (10 22 A m 2). A comparison of all Thellier palaeointensity data from the R3 magnetozone in the Rayinivallahals Mts. area reveals a progressive although irregular increase in the palaeointensity between the Gauss

  14. ELENA MCP detector: absolute efficiency measurement for low energy neutral atoms

    NASA Astrophysics Data System (ADS)

    Rispoli, R.; De Angelis, E.; Colasanti, L.; Vertolli, N.; Orsini, S.; Scheer, J.; Mura, A.; Milillo, A.; Wurz, P.; Selci, S.; Di Lellis, A. M.; Leoni, R.; D'Alessandro, M.; Mattioli, F.; Cibella, S.

    2012-04-01

    MicroChannel plates (MCP) detectors are frequently used in space instrumentation for detecting a wide range of radiation and particles. In particular, the capability to detect non-thermal low energy neutral species is crucial for the sensor ELENA (Emitted Low-Energy Neutral Atoms), part of the package SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) on board the BepiColombo mission to Mercury to be launched in 2014. ELENA is a TOF sensor, based on a novel concept ultra-sonic oscillating shutter (Start section)which is operated at frequencies up to 50 kHz; a MCP detector is used as a Stop section. It is aimed to detect neutral atoms in the range 10 eV - 5 keV, within 70° FOV, perpendicular to the S/C orbital plane. ELENA will monitor the emission of neutral atoms from the whole surface of Mercury thanks to the spacecraft motion. The major scientific objectives are the interaction between the environment and the planet, the global particle loss-rate and the remote sensing of the surface properties. In particular, surface release processes are investigated by identifying particles release from the surface, via solar wind-induced ion sputtering (<1eV and >100 eV) as well as Hydrogen back-scattered at hundreds eV. MCP absolute detection efficiency for very low energy neutral atoms (E< 30eV) is a crucial point not yet investigated. At the MEFISTO facility of the Physical Institute of University of Bern (CH), measurements on three different type of MCPs coating have been performed providing the behaviors of MCP detection efficiency in the range 10eV-1keV. Outcomes from such measurements are here discussed.

  15. Measuring Terrestrial Water Storage Change Using GPS, Absolute Gravity and GRACE in Scandinavia

    NASA Astrophysics Data System (ADS)

    Jia, Lulu; Wang, Hansheng; Wang, Xinsheng

    2015-04-01

    For Scandinavia, terrestrial water storage change estimates from Gravity Recovery and Climate Experiment (GRACE) would be seriously affected by the process of glacial isostatic adjustment (GIA) . The effects of GIA are typically removed using modeled values. However, the uncertainty in current GIA models is very large. To solve this problem, we calculates the measured linear ratio of GIA gravity rates and vertical displacement rates according to the data from collocation stations for absolute gravity and GPS in Scandinavia. Using the linear ratio and uplift field derived from GPS observation network, we get the gravity signal of GIA. Gravity change rates from GRACE RL05 data can be corrected for GIA using independent gravity rates derived from GPS vertical velocities, and then we can calculate corresponding equivalent water thickness in Scandinavia and the uncertainties are evaluated by considering the uncertainties from data. Our method utilizes observational data only and can avoid the enormous uncertainty from GIA models.The results are compared with that of two hydrological models. The ratio of gravity versus uplift obtained by ground-based measurements in Scandinavia is 0.148±0.020μGal/mm, which validates Wahr's approximate theoretical ratio (Wahr et al., 1995) and is very close to the result from North America (Mazzotti et al., 2011). From January 2003 to March 2011, terrestrial water storage shows obvious increase in Scandinavia. The main signal locates at the Vänern lake which is in the southern tip of the peninsula. The rate of total water storage change is 4.6±2.1 Gt/yr and the corresponding cumulative quantity is 38±17 Gt for the period 2003-2011. Results from hydrological models are consistent with our result very well. The correlation coefficient between GRACE and WGHM hydrological model can reach 0.69, while for GLDAS model the correlation coefficient is slightly smaller(0.57)

  16. Solar EUV Monitor (SEM) absolute irradiance measurements and how they are affected by choice of reference spectrum

    NASA Astrophysics Data System (ADS)

    Wieman, Seth R.; Judge, Darrell L.; Didkovsky, Leonid V.

    2011-10-01

    The SOHO/CELIAS Solar EUV Monitor (SEM) has measured absolute extreme ultraviolet (EUV) solar irradiance nearly continuously over a 15 year period that includes two solar cycle minima, 22/23 (1996) and 23/24 (2008). Calibration of the SEM flight instrument and verification of the data have been maintained through measurements from a series of sounding rocket calibration underflights that have included a NIST calibrated SEM clone instrument as well as a Rare Gas Ionization Cell (RGIC) absolute detector. From the beginning of SEM data collection in 1996, the SOLERS 22 fixed reference solar spectrum has been used to calculate absolute EUV flux values from SEM raw data. Specifically, the reference spectrum provides a set of weighting factors for determining a weighted average for the wavelength dependent SEM response. The spectrum is used for calculation of the second order contamination in the first order channel signals, and for the comparison between SEM flux measurements with broader-band absolute RGIC measurements. SOHO/SEM EUV flux measurements for different levels of solar activity will be presented to show how the choice of reference spectra now available affects these SEM data. Both fixed (i.e. SOLERS 22) and non-fixed (Solar Irradiance Platform/Solar 2000 and SDO/EVE/MEGS) reference spectra have been included in this analysis.

  17. Measurement of the absolute branching ratio of the K+ →π+π-π+ (γ) decay with the KLOE detector

    NASA Astrophysics Data System (ADS)

    Babusci, D.; Balwierz-Pytko, I.; Bencivenni, G.; Bloise, C.; Bossi, F.; Branchini, P.; Budano, A.; Caldeira Balkeståhl, L.; Ceradini, F.; Ciambrone, P.; Curciarello, F.; Czerwiński, E.; Danè, E.; De Leo, V.; De Lucia, E.; De Robertis, G.; De Santis, A.; De Simone, P.; Di Cicco, A.; Di Domenico, A.; Di Salvo, R.; Domenici, D.; Erriquez, O.; Fanizzi, G.; Fantini, A.; Felici, G.; Fiore, S.; Franzini, P.; Gajos, A.; Gauzzi, P.; Giardina, G.; Giovannella, S.; Graziani, E.; Happacher, F.; Heijkenskjöld, L.; Höistad, B.; Johansson, T.; Kamińska, D.; Krzemien, W.; Kupsc, A.; Lee-Franzini, J.; Loddo, F.; Loffredo, S.; Mandaglio, G.; Martemianov, M.; Martini, M.; Mascolo, M.; Messi, R.; Miscetti, S.; Morello, G.; Moricciani, D.; Moskal, P.; Palladino, A.; Passeri, A.; Patera, V.; Prado Longhi, I.; Ranieri, A.; Santangelo, P.; Sarra, I.; Schioppa, M.; Sciascia, B.; Silarski, M.; Tortora, L.; Venanzoni, G.; Wiślicki, W.; Wolke, M.

    2014-11-01

    The absolute branching ratio of the K+ →π+π-π+ (γ) decay, inclusive of final-state radiation, has been measured using ∼17 million tagged K+ mesons collected with the KLOE detector at DAΦNE, the Frascati ϕ-factory.

  18. The orbit of Phi Cygni measured with long-baseline optical interferometry - Component masses and absolute magnitudes

    NASA Technical Reports Server (NTRS)

    Armstrong, J. T.; Hummel, C. A.; Quirrenbach, A.; Buscher, D. F.; Mozurkewich, D.; Vivekanand, M.; Simon, R. S.; Denison, C. S.; Johnston, K. J.; Pan, X.-P.

    1992-01-01

    The orbit of the double-lined spectroscopic binary Phi Cygni, the distance to the system, and the masses and absolute magnitudes of its components are presented via measurements with the Mar III Optical Interferometer. On the basis of a reexamination of the spectroscopic data of Rach & Herbig (1961), the values and uncertainties are adopted for the period and the projected semimajor axes from the present fit to the spectroscopic data and the values of the remaining elements from the present fit to the Mark III data. The elements of the true orbit are derived, and the masses and absolute magnitudes of the components, and the distance to the system are calculated.

  19. Reduced Haemodynamic Response in the Ageing Visual Cortex Measured by Absolute fNIRS

    PubMed Central

    Ward, Laura McKernan; Aitchison, Ross Thomas; Tawse, Melisa; Simmers, Anita Jane; Shahani, Uma

    2015-01-01

    The effect of healthy ageing on visual cortical activation is still to be fully explored. This study aimed to elucidate whether the haemodynamic response (HDR) of the visual cortex altered as a result of ageing. Visually normal (healthy) participants were presented with a simple visual stimulus (reversing checkerboard). Full optometric screening was implemented to identify two age groups: younger adults (n = 12, mean age 21) and older adults (n = 13, mean age 71). Frequency-domain Multi-distance (FD-MD) functional Near-Infrared Spectroscopy (fNIRS) was used to measure absolute changes in oxygenated [HbO] and deoxygenated [HbR] haemoglobin concentrations in the occipital cortices. Utilising a slow event-related design, subjects viewed a full field reversing checkerboard with contrast and check size manipulations (15 and 30 minutes of arc, 50% and 100% contrast). Both groups showed the characteristic response of increased [HbO] and decreased [HbR] during stimulus presentation. However, older adults produced a more varied HDR and often had comparable levels of [HbO] and [HbR] during both stimulus presentation and baseline resting state. Younger adults had significantly greater concentrations of both [HbO] and [HbR] in every investigation regardless of the type of stimulus displayed (p<0.05). The average variance associated with this age-related effect for [HbO] was 88% and [HbR] 91%. Passive viewing of a visual stimulus, without any cognitive input, showed a marked age-related decline in the cortical HDR. Moreover, regardless of stimulus parameters such as check size, the HDR was characterised by age. In concurrence with present neuroimaging literature, we conclude that the visual HDR decreases as healthy ageing proceeds. PMID:25909849

  20. Absolute measurement of dielectronic recombination for C{sup 3+} in a known external field

    SciTech Connect

    Savin, D.W.; Gardner, L.D.; Reisenfeld, D.B.; Young, A.R.; Kohl, J.L.

    1996-01-01

    An absolute measurement of the rate coefficient for dielectronic recombination (DR) of C{sup 3+}, via the 2{ital s}-2{ital p} core excitation, in an external electric field of 11.4{plus_minus}0.9(1{sigma}) Vcm{sup {minus}1} is presented. An inclined-beam arrangement is used and the stabilizing photons at {approximately}155 nm are detected in delayed coincidence with the recombined ions. The full width at half maximum of the electron energy spread in the ion rest frame is 1.74{plus_minus}0.22(1{sigma}) eV. The measured DR rate, at a mean electron energy of 8.26{plus_minus}0.07(1{sigma}) eV, is (2.76{plus_minus}0.75){times}10{sup {minus}10} cm{sup 3}s{sup {minus}1}. The uncertainty quoted for the DR rate is the total uncertainty, systematic and statistical, at the 1{sigma} level. In comparing the present results to theory, a semiempirical formula is used to determine which recombined ion states are ionized by the 4.65 kVcm{sup {minus}1} fields in the final-charge-state analyzer and not detected. For the present results, any DR of the incident electrons into {ital n} levels greater than 44 is assumed to be field ionized in the final-charge-state analyzer. A more precise treatment of field ionization, which includes the lifetime of the C{sup 2+} ions before they are ionized and the time evolution and rotation of the fields experienced by the recombined ions, is needed before a definitive comparison between experiment and theory can be made. Our DR measurement, within the limits of that approach, agrees reasonably well with an intermediate coupling calculation that uses an isolated resonance, single-configuration approximation, but does not agree with pure {ital LS}-coupling calculations. {copyright} {ital 1996 The American Physical Society.}

  1. Normal incidence spectrophotometer using high density transmission grating technology and highly efficiency silicon photodiodes for absolute solar EUV irradiance measurements

    NASA Technical Reports Server (NTRS)

    Ogawa, H. S.; Mcmullin, D.; Judge, D. L.; Korde, R.

    1992-01-01

    New developments in transmission grating and photodiode technology now make it possible to realize spectrometers in the extreme ultraviolet (EUV) spectral region (wavelengths less than 1000 A) which are expected to be virtually constant in their diffraction and detector properties. Time dependent effects associated with reflection gratings are eliminated through the use of free standing transmission gratings. These gratings together with recently developed and highly stable EUV photodiodes have been utilized to construct a highly stable normal incidence spectrophotometer to monitor the variability and absolute intensity of the solar 304 A line. Owing to its low weight and compactness, such a spectrometer will be a valuable tool for providing absolute solar irradiance throughout the EUV. This novel instrument will also be useful for cross-calibrating other EUV flight instruments and will be flown on a series of Hitchhiker Shuttle Flights and on SOHO. A preliminary version of this instrument has been fabricated and characterized, and the results are described.

  2. Measurement of absolute auditory thresholds in the common marmoset (Callithrix jacchus)

    PubMed Central

    Osmanski, Michael S.; Wang, Xiaoqin

    2011-01-01

    The common marmoset is a small, arboreal, New World primate that has emerged as a promising non-human model system in auditory neuroscience. A complete understanding of the neuroethology of auditory processing in marmosets will include behavioral work examining how sounds are perceived by these animals. However, there have been few studies of the marmoset’s hearing and perceptual abilities and the audiogram of this species has not been measured using modern psychophysical methods. The present experiment pairs psychophysics with an operant conditioning technique to examine perception of pure tone stimuli by marmosets using an active behavioral paradigm. Subjects were trained to lick at a feeding tube when they detected a sound. Correct responses provided access to a food reward. Pure tones of varying intensities were presented to subjects using the method of constant stimuli. Behavioral thresholds were calculated for each animal based on hit rate - threshold was defined by the tone intensity that the animal correctly identified 50% of the time. Results show that marmoset hearing is comparable to that of other New World monkeys, with a hearing range extending from about 125 Hz up to 36 kHz and a sensitivity peak around 7 kHz. PMID:21303689

  3. Absolute gravity measurements in Southeast Alaska and continuous gravity observation in Juneau by ISEA2 project

    NASA Astrophysics Data System (ADS)

    Sato, T.; Kazama, T.; Miura, S.; Ohta, Y.; Okubo, S.; Fujimoto, H.; Kaufman, M.; Herreid, S. J.; Larsen, C. F.; Freymueller, J. T.

    2012-12-01

    It is known that Southeast Alaska (SE-AK) shows a large uplift rates exceeding 32 mm/year at the maximum mainly due to the three ice changes in ages, i.e. in the Large Glacier Maximum, the Little Ice Age and the present day. Comparisons between rates of change obtained from GPS and absolute gravimeter (AG) observations and the rates predicted by model computations based on independently estimated ice mass changes indicate the existence of a very thin lithosphere (on the order of 60 km) and a low viscousity upper mantle (on the order of 1.E18 Pa s) beneath SE-AK (Larsen et al., 2005; Sato et al, 2011; Sato et al., 2012). On the other hand, it is also known that there are very large oceanic tidal loading effects in SE-AK, i.e. exceeding 2.7 cm and 8 microGals for the M2 constituent of the vertical displacement and gravity, respectively (Sato et al., 2008; Inazu et al., 2009; Sun et al., 2010; Sato et al., 2012). These regional large loading and unloading effects provide good signals to study the viscoelastic structure beneath SE-AK. A joint observation project (ISEA2) between Japan and USA groups has restarted as a five years project beginning in 2012. In June 2012, we conducted the AG measurements at the 6 sites in SE-AK at where the AG measurements were conducted by the previous ISEA1 project (Sun et al., 2010). Continuous gravity observation started also on June 2012 with a portable super conducting gravimeter (iGrav) at the EGAN library of UAS. We will introduce the results for these observations and comparisons with the previous observations and model computations. It is noted that the precipitation during the period from the winter in 2011 to the spring in 2012 was very large compared with the usual amount. We evaluate this effect on our gravity observations with a hydrological model computation (Kazama and Okubo, 2009) using the observed precipitation data as an input data. The observation with the iGrav super conducting gravimeter shall give us a useful data

  4. Absolute OH density measurements in an atmospheric pressure dc glow discharge in air with water electrode by broadband UV absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Xiong, Qing; Yang, Zhiqiang; Bruggeman, Peter J.

    2015-10-01

    Spatially resolved absolute OH radical density measurements are performed in an atmospheric pressure glow discharge generated in ambient air with water electrode by broadband UV absorption spectroscopy. The radial distributions of OH density and gas temperature are obtained for the positive column, anode and cathode regions both for water-cathode and water-anode discharges. It is found that for both polarities of the water electrode the radial profiles of the ground state OH density and gas temperature are significantly broader than the total discharge emission intensity and the emission intensity originating from OH(\\text{A}{}2{{\\text{ }Σ\\text{ }}+} ) only. Exceptional large OH densities exceeding 1023 m-3 are found. The OH kinetics are discussed in detail.

  5. Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly

    NASA Technical Reports Server (NTRS)

    Merle, Cormic; Wick, Eric; Hayden, Joseph

    2011-01-01

    This system was one of the test methods considered for measuring the radius of curvature of one or more of the 18 segmented mirrors that form the 6.5 m diameter primary mirror (PM) of the James Webb Space Telescope (JWST). The assembled telescope will be tested at cryogenic temperatures in a 17-m diameter by 27-m high vacuum chamber at the Johnson Space Center. This system uses a Leica Absolute Distance Meter (ADM), at a wavelength of 780 nm, combined with beam-steering and beam-shaping optics to make a differential distance measurement between a ring mirror on the reflective null assembly and individual PM segments. The ADM is located inside the same Pressure-Tight Enclosure (PTE) that houses the test interferometer. The PTE maintains the ADM and interferometer at ambient temperature and pressure so that they are not directly exposed to the telescope s harsh cryogenic and vacuum environment. This system takes advantage of the existing achromatic objective and reflective null assembly used by the test interferometer to direct four ADM beamlets to four PM segments through an optical path that is coincident with the interferometer beam. A mask, positioned on a linear slide, contains an array of 1.25 mm diameter circular subapertures that map to each of the 18 PM segments as well as six positions around the ring mirror. A down-collimated 4 mm ADM beam simultaneously covers 4 adjacent PM segment beamlets and one ring mirror beamlet. The radius, or spacing, of all 18 segments can be measured with the addition of two orthogonally-oriented scanning pentaprisms used to steer the ADM beam to any one of six different sub-aperture configurations at the plane of the ring mirror. The interferometer beam, at a wavelength of 687 nm, and the ADM beamlets, at a wavelength of 780 nm, pass through the objective and null so that the rays are normally incident on the parabolic PM surface. After reflecting off the PM, both the ADM and interferometer beams return to their respective

  6. Design of a quasi-zero-stiffness based sensor system for the measurement of absolute vibration displacement of moving platforms

    NASA Astrophysics Data System (ADS)

    Jing, Xingjian; Wang, Yu; Li, Quankun; Sun, Xiuting

    2016-09-01

    This study presents the analysis and design of a novel sensor system for measuring the absolute vibration displacement of moving platforms based on the concept of quasi-zero-stiffness (QZS). The sensor system is constructed using positive- and negative-stiffness springs, which make it possible to achieve an equivalent QZS and consequently to create a broadband vibration-free point for absolute vibration displacement measurement in moving platforms. Theoretical analysis is conducted for the analysis and design of the influence of structure parameters on system measurement performance. A prototype is designed which can avoid the drawback of instability in existing QZS systems with negative stiffness, and corresponding data-processing software is developed to fulfill time domain measurements. Both the simulation and experimental results verify the effectiveness of this novel sensor system.

  7. High-accuracy interferometer with a prism pair for measurement of the absolute refractive index of glass

    SciTech Connect

    Hori, Yasuaki; Hirai, Akiko; Minoshima, Kaoru; Matsumoto, Hirokazu

    2009-04-10

    We propose a variable-path interferometric technique for the measurement of the absolute refractive index of optical glasses. We use two interferometers to decide the ratio between changes in the optical path in a prism-shaped sample glass and in air resulting from displacement of the sample. The method allows precise measurements to be made without prior knowledge of the properties of the sample. The combined standard uncertainty of the proposed method is 1.6x10{sup -6}.

  8. Measurement of Absolute Excitation Cross Sections in Highly-Charged Ions Using Electron Energy Loss and Merged Beams

    NASA Astrophysics Data System (ADS)

    Chutjian, A.; Smith, Steven J.; Lozano, J. A.

    2002-11-01

    There is increasing emphasis within this decade on understanding energy balance and new phenomena observed in high electron temperature plasmas. The UV spectral return from FUSE, and the X-ray spectral return from the HETG on Chandra and the LETGS on XMM-Newton are just beginning. The line emissions are almost entirely from highly-charged ions (HCIs) of C, N, O, Ne, Mg, S, Si, Ca, and Fe. In addition, the Constellation-X mission, currently in the planning stages, will provide high-throughput X-ray spectroscopy up to photon energies of 0.12 nm (10 keV), where the primary line emitters will again be the HCIs. This array of space instruments is providing an overwhelming return of HCI spectral data from a variety of astrophysical objects. Collision strengths and Einstein A-values are required to convert the observed spectral intensities to electron temperatures and densities in the stellar plasma [1]. The JPL electron energy-loss and merged-beams approach [2] has been used to measure absolute collision strengths in a number of ions, with critical comparisons to the best available theories. Experimental methods will be reviewed, and results presented on experimental comparisons to R-Matrix and Breit-Pauli theoretical results in C3+[3], O2+[4], O5+[5], S2+[6], and Fe9+ [7]. Work is planned for comparisons in Mgq+, and higher charge states Fe(10-15)+. J. Lozano thanks the National Research Council for a fellowship though the NASA- NRC program. This work was carried out at the Jet Propulsion Laboratory, California Institute of Technology, and was supported under contract with the National Aeronautics and Space Administration.

  9. An intensive Alpine climbing expedition and its influence on some anthropometric measurements.

    PubMed Central

    Baker, S. J.

    1980-01-01

    The effects of an intensive 4 week Alpine climbing expedition on percentage body fat, absolute body fat and lean body mass was investigated in 14 adult male students. Anthropometric measures were taken on two occasions during the training period prior to the expedition, twice during the expedition and finally eight weeks after the expedition had returned home. There was a 3% reduction in percentage body fat between the first testing occasion and the fourth taken towards the end of the expedition. Over the same interval there was a mean reduction of 2.6 kg in absolute body fat and a reduction in lean body mass of 2.47 kg. All three criterion mean values on the final testing session returned to or exceeded those taken on session one. Images p126-a Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:7407450

  10. Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF.

    PubMed

    Casey, D T; Frenje, J A; Gatu Johnson, M; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Knauer, J P; Meyerhofer, D D; Sangster, T C; Bionta, R M; Bleuel, D L; Döppner, T; Glenzer, S; Hartouni, E; Hatchett, S P; Le Pape, S; Ma, T; MacKinnon, A; McKernan, M A; Moran, M; Moses, E; Park, H-S; Ralph, J; Remington, B A; Smalyuk, V; Yeamans, C B; Kline, J; Kyrala, G; Chandler, G A; Leeper, R J; Ruiz, C L; Cooper, G W; Nelson, A J; Fletcher, K; Kilkenny, J; Farrell, M; Jasion, D; Paguio, R

    2012-10-01

    A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  11. Measuring Absolute RNA Copy Numbers at High Temporal Resolution Reveals Transcriptome Kinetics in Development.

    PubMed

    Owens, Nick D L; Blitz, Ira L; Lane, Maura A; Patrushev, Ilya; Overton, John D; Gilchrist, Michael J; Cho, Ken W Y; Khokha, Mustafa K

    2016-01-26

    Transcript regulation is essential for cell function, and misregulation can lead to disease. Despite technologies to survey the transcriptome, we lack a comprehensive understanding of transcript kinetics, which limits quantitative biology. This is an acute challenge in embryonic development, where rapid changes in gene expression dictate cell fate decisions. By ultra-high-frequency sampling of Xenopus embryos and absolute normalization of sequence reads, we present smooth gene expression trajectories in absolute transcript numbers. During a developmental period approximating the first 8 weeks of human gestation, transcript kinetics vary by eight orders of magnitude. Ordering genes by expression dynamics, we find that "temporal synexpression" predicts common gene function. Remarkably, a single parameter, the characteristic timescale, can classify transcript kinetics globally and distinguish genes regulating development from those involved in cellular metabolism. Overall, our analysis provides unprecedented insight into the reorganization of maternal and embryonic transcripts and redefines our ability to perform quantitative biology.

  12. Absolute brightness temperature measurements at 3.5-mm wavelength. [of sun, Venus, Jupiter and Saturn

    NASA Technical Reports Server (NTRS)

    Ulich, B. L.; Rhodes, P. J.; Davis, J. H.; Hollis, J. M.

    1980-01-01

    Careful observations have been made at 86.1 GHz to derive the absolute brightness temperatures of the sun (7914 + or - 192 K), Venus (357.5 + or - 13.1 K), Jupiter (179.4 + or - 4.7 K), and Saturn (153.4 + or - 4.8 K) with a standard error of about three percent. This is a significant improvement in accuracy over previous results at millimeter wavelengths. A stable transmitter and novel superheterodyne receiver were constructed and used to determine the effective collecting area of the Millimeter Wave Observatory (MWO) 4.9-m antenna relative to a previously calibrated standard gain horn. The thermal scale was set by calibrating the radiometer with carefully constructed and tested hot and cold loads. The brightness temperatures may be used to establish an absolute calibration scale and to determine the antenna aperture and beam efficiencies of other radio telescopes at 3.5-mm wavelength.

  13. The determination of absolute intensity of 234mPa's 1001 keV gamma emission using Monte Carlo simulation.

    PubMed

    Begy, Robert-Csaba; Cosma, Constantin; Timar, Alida; Fulea, Dan

    2009-05-01

    The 1001 keV gamma line of (234m)Pa became important in gamma spectrometric measurements of samples with (238)U content with the advent of development of HpGe detectors of great dimension and high efficiency. In this study the emission probability of the 1001 keV (Y(gamma)) peak of (234m)Pa, was determined by gamma-ray spectrometric measurements performed on glass with Uranium content using Monte Carlo simulation code for efficiency calibration. This method of calculation was not applied for the values quoted in literature so far, at least to our knowledge. The measurements gave an average of 0.836 +/- 0.022%, a value that is in very good agreement to some of the recent results previously presented.

  14. The determination of absolute intensity of 234mPa's 1001 keV gamma emission using Monte Carlo simulation.

    PubMed

    Begy, Robert-Csaba; Cosma, Constantin; Timar, Alida; Fulea, Dan

    2009-05-01

    The 1001 keV gamma line of (234m)Pa became important in gamma spectrometric measurements of samples with (238)U content with the advent of development of HpGe detectors of great dimension and high efficiency. In this study the emission probability of the 1001 keV (Y(gamma)) peak of (234m)Pa, was determined by gamma-ray spectrometric measurements performed on glass with Uranium content using Monte Carlo simulation code for efficiency calibration. This method of calculation was not applied for the values quoted in literature so far, at least to our knowledge. The measurements gave an average of 0.836 +/- 0.022%, a value that is in very good agreement to some of the recent results previously presented. PMID:19384056

  15. Phase-sensitive swept-source interferometry for absolute ranging with application to measurements of group refractive index and thickness.

    PubMed

    Moore, Eric D; McLeod, Robert R

    2011-04-25

    Interferometric range measurements using a wavelength-tunable source form the basis of several measurement techniques, including optical frequency domain reflectometry (OFDR), swept-source optical coherence tomography (SS-OCT), and frequency-modulated continuous wave (FMCW) lidar. We present a phase-sensitive and self-referenced approach to swept-source interferometry that yields absolute range measurements with axial precision three orders of magnitude better than the transform-limited axial resolution of the system. As an example application, we implement the proposed method for a simultaneous measurement of group refractive index and thickness of an optical glass sample. PMID:21643062

  16. Absolute frequency measurement of an acetylene stabilized laser using a selected single mode from a femtosecond fiber laser comb.

    PubMed

    Ryu, Han Young; Lee, Sung Hun; Lee, Won Kyu; Moon, Han Seb; Suh, Ho Suhng

    2008-03-01

    We performed an absolute frequency measurement of an acetylene stabilized laser utilizing a femtosecond injection locking technique that can select one component among the fiber laser comb modes. The injection locking scheme has all the fiber configurations. Femtosecond comb lines of 250 MHz spacing based on the fiber femtosecond laser were used for injection locking of a distributed feedback (DFB) laser operating at 1542 nm as a frequency reference. The comb injected DFB laser serves as a selection filter of optical comb modes and an amplifier for amplification of the selected mode. The DFB laser injection locked to the desired comb mode was used to evaluate the frequency stability and absolute frequency measurement of an acetylene stabilized laser. The frequency stability of the acetylene stabilized laser was measured to be 1.1 x 10(-12) for a 1 s averaging time, improving to 6.9 x 10(-14) after 512 s. The absolute frequency of the laser stabilized on the P(16) transition of (13)C(2)H(2) was measured to be 194 369 569 385.7 kHz.

  17. Separating climate-induced mass transfers and instrumental effects from tectonic signal in repeated absolute gravity measurements

    NASA Astrophysics Data System (ADS)

    Van Camp, M.; Viron, O.; Avouac, J. P.

    2016-05-01

    We estimate the signature of the climate-induced mass transfers in repeated absolute gravity measurements based on satellite gravimetric measurements from the Gravity Recovery and Climate Experiment (GRACE) mission. We show results at the globe scale and compare them with repeated absolute gravity (AG) time behavior in three zones where AG surveys have been published: Northwestern Europe, Canada, and Tibet. For 10 yearly campaigns, the uncertainties affecting the determination of a linear gravity rate of change range 3-4 nm/s2/a in most cases, in the absence of instrumental artifacts. The results are consistent with what is observed for long-term repeated campaigns. We also discuss the possible artifact that can result from using short AG survey to determine the tectonic effects in a zone of high hydrological variability. We call into question the tectonic interpretation of several gravity changes reported from stations in Tibet, in particular the variation observed prior to the 2015 Gorkha earthquake.

  18. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    PubMed

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted.

  19. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    PubMed

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted. PMID:27245647

  20. Time-resolved absolute measurements by electro-optic effect of giant electromagnetic pulses due to laser-plasma interaction in nanosecond regime.

    PubMed

    Consoli, F; De Angelis, R; Duvillaret, L; Andreoli, P L; Cipriani, M; Cristofari, G; Di Giorgio, G; Ingenito, F; Verona, C

    2016-01-01

    We describe the first electro-optical absolute measurements of electromagnetic pulses (EMPs) generated by laser-plasma interaction in nanosecond regime. Laser intensities are inertial-confinement-fusion (ICF) relevant and wavelength is 1054 nm. These are the first direct EMP amplitude measurements with the detector rather close and in direct view of the plasma. A maximum field of 261 kV/m was measured, two orders of magnitude higher than previous measurements by conductive probes on nanosecond regime lasers with much higher energy. The analysis of measurements and of particle-in-cell simulations indicates that signals match the emission of charged particles detected in the same experiment, and suggests that anisotropic particle emission from target, X-ray photoionization and charge implantation on surfaces directly exposed to plasma, could be important EMP contributions. Significant information achieved on EMP features and sources is crucial for future plants of laser-plasma acceleration and inertial-confinement-fusion and for the use as effective plasma diagnostics. It also opens to remarkable applications of laser-plasma interaction as intense source of RF-microwaves for studies on materials and devices, EMP-radiation-hardening and electromagnetic compatibility. The demonstrated extreme effectivity of electric-fields detection in laser-plasma context by electro-optic effect, leads to great potential for characterization of laser-plasma interaction and generated Terahertz radiation. PMID:27301704

  1. Time-resolved absolute measurements by electro-optic effect of giant electromagnetic pulses due to laser-plasma interaction in nanosecond regime

    PubMed Central

    Consoli, F.; De Angelis, R.; Duvillaret, L.; Andreoli, P. L.; Cipriani, M.; Cristofari, G.; Di Giorgio, G.; Ingenito, F.; Verona, C.

    2016-01-01

    We describe the first electro-optical absolute measurements of electromagnetic pulses (EMPs) generated by laser-plasma interaction in nanosecond regime. Laser intensities are inertial-confinement-fusion (ICF) relevant and wavelength is 1054 nm. These are the first direct EMP amplitude measurements with the detector rather close and in direct view of the plasma. A maximum field of 261 kV/m was measured, two orders of magnitude higher than previous measurements by conductive probes on nanosecond regime lasers with much higher energy. The analysis of measurements and of particle-in-cell simulations indicates that signals match the emission of charged particles detected in the same experiment, and suggests that anisotropic particle emission from target, X-ray photoionization and charge implantation on surfaces directly exposed to plasma, could be important EMP contributions. Significant information achieved on EMP features and sources is crucial for future plants of laser-plasma acceleration and inertial-confinement-fusion and for the use as effective plasma diagnostics. It also opens to remarkable applications of laser-plasma interaction as intense source of RF-microwaves for studies on materials and devices, EMP-radiation-hardening and electromagnetic compatibility. The demonstrated extreme effectivity of electric-fields detection in laser-plasma context by electro-optic effect, leads to great potential for characterization of laser-plasma interaction and generated Terahertz radiation. PMID:27301704

  2. Time-resolved absolute measurements by electro-optic effect of giant electromagnetic pulses due to laser-plasma interaction in nanosecond regime

    NASA Astrophysics Data System (ADS)

    Consoli, F.; de Angelis, R.; Duvillaret, L.; Andreoli, P. L.; Cipriani, M.; Cristofari, G.; di Giorgio, G.; Ingenito, F.; Verona, C.

    2016-06-01

    We describe the first electro-optical absolute measurements of electromagnetic pulses (EMPs) generated by laser-plasma interaction in nanosecond regime. Laser intensities are inertial-confinement-fusion (ICF) relevant and wavelength is 1054 nm. These are the first direct EMP amplitude measurements with the detector rather close and in direct view of the plasma. A maximum field of 261 kV/m was measured, two orders of magnitude higher than previous measurements by conductive probes on nanosecond regime lasers with much higher energy. The analysis of measurements and of particle-in-cell simulations indicates that signals match the emission of charged particles detected in the same experiment, and suggests that anisotropic particle emission from target, X-ray photoionization and charge implantation on surfaces directly exposed to plasma, could be important EMP contributions. Significant information achieved on EMP features and sources is crucial for future plants of laser-plasma acceleration and inertial-confinement-fusion and for the use as effective plasma diagnostics. It also opens to remarkable applications of laser-plasma interaction as intense source of RF-microwaves for studies on materials and devices, EMP-radiation-hardening and electromagnetic compatibility. The demonstrated extreme effectivity of electric-fields detection in laser-plasma context by electro-optic effect, leads to great potential for characterization of laser-plasma interaction and generated Terahertz radiation.

  3. Time-resolved absolute measurements by electro-optic effect of giant electromagnetic pulses due to laser-plasma interaction in nanosecond regime.

    PubMed

    Consoli, F; De Angelis, R; Duvillaret, L; Andreoli, P L; Cipriani, M; Cristofari, G; Di Giorgio, G; Ingenito, F; Verona, C

    2016-06-15

    We describe the first electro-optical absolute measurements of electromagnetic pulses (EMPs) generated by laser-plasma interaction in nanosecond regime. Laser intensities are inertial-confinement-fusion (ICF) relevant and wavelength is 1054 nm. These are the first direct EMP amplitude measurements with the detector rather close and in direct view of the plasma. A maximum field of 261 kV/m was measured, two orders of magnitude higher than previous measurements by conductive probes on nanosecond regime lasers with much higher energy. The analysis of measurements and of particle-in-cell simulations indicates that signals match the emission of charged particles detected in the same experiment, and suggests that anisotropic particle emission from target, X-ray photoionization and charge implantation on surfaces directly exposed to plasma, could be important EMP contributions. Significant information achieved on EMP features and sources is crucial for future plants of laser-plasma acceleration and inertial-confinement-fusion and for the use as effective plasma diagnostics. It also opens to remarkable applications of laser-plasma interaction as intense source of RF-microwaves for studies on materials and devices, EMP-radiation-hardening and electromagnetic compatibility. The demonstrated extreme effectivity of electric-fields detection in laser-plasma context by electro-optic effect, leads to great potential for characterization of laser-plasma interaction and generated Terahertz radiation.

  4. In situ TDLAS measurement of absolute acetylene concentration profiles in a non-premixed laminar counter-flow flame

    NASA Astrophysics Data System (ADS)

    Wagner, S.; Klein, M.; Kathrotia, T.; Riedel, U.; Kissel, T.; Dreizler, A.; Ebert, V.

    2012-06-01

    Acetylene (C2H2), as an important precursor for chemiluminescence species, is a key to understand, simulate and model the chemiluminescence and the related reaction paths. Hence we developed a high resolution spectrometer based on direct Tunable Diode Laser Absorption Spectroscopy (TDLAS) allowing the first quantitative, calibration-free and spatially resolved in situ C2H2 measurement in an atmospheric non-premixed counter-flow flame supported on a Tsuji burner. A fiber-coupled distributed feedback diode laser near 1535 nm was used to measure several absolute C2H2 concentration profiles (peak concentrations up to 9700 ppm) in a laminar non-premixed CH4/air flame ( T up to 1950 K) supported on a modified Tsuji counter-flow burner with N2 purge slots to minimize end flames. We achieve a fractional optical resolution of up to 5×10-5 OD (1 σ) in the flame, resulting in temperature-dependent acetylene detection limits for the P17e line at 6513 cm-1 of up to 2.1 ppmṡm. Absolute C2H2 concentration profiles were obtained by translating the burner through the laser beam using a DC motor with 100 μm step widths. Intercomparisons of the experimental C2H2 profiles with simulations using our new hydrocarbon oxidation mechanisms show excellent agreement in position, shape and in the absolute C2H2 values.

  5. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  6. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  7. Gas-phase NMR measurements, absolute shielding scales, and magnetic dipole moments of 29Si and 73Ge nuclei.

    PubMed

    Makulski, W; Jackowski, K; Antusek, A; Jaszuński, M

    2006-10-12

    New gas-phase NMR measurements of the shielding constants of 29Si, 73Ge, and 1H nuclei in SiH4 and GeH4 are reported. The results, extrapolated to zero density, provide accurate isolated molecule values, best suited for comparison with theoretical calculations. Using the recent ab initio results for these molecules and the measured chemical shifts, we determine the absolute shielding scales for 29Si and 73Ge. This allows us to provide new values of the nuclear magnetic dipole moments for these two nuclei; in addition, we examine the dipole moments of 13C and 119Sn.

  8. SOHO/CELIAS Solar EUV Monitor (SEM) Absolute Solar EUV Irradiance Measurements Spanning Two Solar Minima (Invited)

    NASA Astrophysics Data System (ADS)

    Wieman, S. R.; Didkovsky, L. V.; Judge, D.

    2010-12-01

    The SOHO/CELIAS Solar EUV Monitor (SEM) has measured absolute EUV solar irradiance nearly continuously over a 15 year period that includes both the cycle 22/23 (1996) and cycle 23/24 (2008) solar minima. These measurements indicate that irradiance in the 26-34 nm spectral range, including the dominant He II 30.4 nm spectral line, was about 15% ± 6% lower during the more recent minimum compared to the previous minimum. The SEM data have been verified against measurements from seven sounding rocket calibration underflights that included a NIST calibrated SEM clone instrument as well as a Rare Gas Ionization Cell (RGIC) absolute extreme ultraviolet (EUV) detector. Additionally, the SEM measurements are in good agreement with measurements from the EUV Spectrophotomer (ESP) part of the EUV Variability Experiment (EVE) on SDO. ESP measurements from the EVE sounding rocket flight (2008) confirmed the very low solar EUV irradiance observed during the 23/24 minimum. A comparison of SEM and ESP data in the 30.4 nm spectral windows is presented.

  9. Absolute OH density measurements by broadband UV absorption in diffuse atmospheric-pressure He-H2O RF glow discharges

    NASA Astrophysics Data System (ADS)

    Bruggeman, Peter; Cunge, Gilles; Sadeghi, Nader

    2012-06-01

    The measurement of radical densities in atmospheric-pressure plasmas has gained increasing importance in recent years in view of their crucial role in many applications. In this paper we present absolute OH density measurements by broadband UV absorption in diffuse atmospheric-pressure RF glow discharges in mixtures of He and H2O. The use of a 310 nm light-emitting diode as a light source and a very high resolution spectrometer (2.6 pm resolution) made the estimation of the total OH density possible by simultaneously measuring the absorption rates of different spectrally resolved rotational lines of the OH(A-X) transition. For different RF powers and water concentrations, OH densities and gas temperatures ranging between 6 × 1019and 4 × 1020 m-3 and 345 and 410 K, respectively, were obtained. The gas temperature Tg was also measured by three different methods. Tg deduced from the rotational temperature of N2(C-B) emission, nitrogen being present as a trace impurity, provided the most reliable value. The rotational temperature Tr of the ground state OH(X) presented values with a maximum deviation of 25 K compared with Tg. To obtain the gas temperature from the emission intensities of OH(A-X) rotational lines, the recorded intensities of different lines must be corrected for the effect of self-absorption inside the plasma.

  10. Surface acoustical intensity measurements on a diesel engine

    NASA Technical Reports Server (NTRS)

    Mcgary, M. C.; Crocker, M. J.

    1980-01-01

    The use of surface intensity measurements as an alternative to the conventional selective wrapping technique of noise source identification and ranking on diesel engines was investigated. A six cylinder, in line turbocharged, 350 horsepower diesel engine was used. Sound power was measured under anechoic conditions for eight separate parts of the engine at steady state operating conditions using the conventional technique. Sound power measurements were repeated on five separate parts of the engine using the surface intensity at the same steady state operating conditions. The results were compared by plotting sound power level against frequency and noise source rankings for the two methods.

  11. Exploring Intensive Longitudinal Measures of Student Engagement in Blended Learning

    ERIC Educational Resources Information Center

    Henrie, Curtis R.; Bodily, Robert; Manwaring, Kristine C.; Graham, Charles R.

    2015-01-01

    In this exploratory study we used an intensive longitudinal approach to measure student engagement in a blended educational technology course, collecting both self-report and observational data. The self-report measure included a simple survey of Likert-scale and open-ended questions given repeatedly during the semester. Observational data were…

  12. Absolute distance measurement by multi-heterodyne interferometry using a frequency comb and a cavity-stabilized tunable laser.

    PubMed

    Wu, Hanzhong; Zhang, Fumin; Liu, Tingyang; Balling, Petr; Qu, Xinghua

    2016-05-20

    In this paper, we develop a multi-heterodyne system capable of absolute distance measurement using a frequency comb and a tunable diode laser locked to a Fabry-Perot cavity. In a series of subsequent measurements, numerous beat components can be obtained by downconverting the optical frequency into the RF region with multi-heterodyne interferometry. The distances can be measured via the mode phases with a series of synthetic wavelengths. The comparison with the reference interferometer shows an agreement within 1.5 μm for the averages of five measurements and 2.5 μm for the single measurement, which is at the 10-8 relative precision level. PMID:27411152

  13. Characterization and Absolute QE Measurements of Delta-Doped N-Channel and P-Channel CCDs

    NASA Technical Reports Server (NTRS)

    Jacquot, Blake C.; Monacos, Steve P.; Jones, Todd J.; Blacksberg, Jordana; Hoenk, Michael E.; Nikzad, Shouleh

    2010-01-01

    In this paper we present the methodology for making absolute quantum efficiency (QE) measurements from the vacuum ultraviolet (VUV) through the near infrared (NIR) on delta-doped silicon CCDs. Delta-doped detectors provide an excellent platform to validate measurements through the VUV due to their enhanced UV response. The requirements for measuring QE through the VUV are more strenuous than measurements in the near UV and necessitate, among other things, the use of a vacuum monochromator, and good camera vacuum to prevent chip condensation, and more stringent handling requirements. The system used for these measurements was originally designed for deep UV characterization of CCDs for the WF/PC instrument on Hubble and later for Cassini CCDs.

  14. Absolute measurements of total peroxy nitrate mixing ratios by thermal dissociation blue diode laser cavity ring-down spectroscopy.

    PubMed

    Paul, Dipayan; Osthoff, Hans D

    2010-08-01

    Peroxycarboxylic nitric anhydrides (PANs) have long been recognized as important trace gas constituents of the troposphere. Here, we describe a blue diode laser thermal dissociation cavity ring-down spectrometer for rapid and absolute measurements of total peroxyacyl nitrate (SigmaPAN) abundances at ambient concentration levels. The PANs are thermally dissociated and detected as NO2, whose mixing ratios are quantified by optical absorption at 405 nm relative to a reference channel kept at ambient temperature. The effective NO2 absorption cross-section at the diode laser emission wavelength was measured to be 6.1 x 10(-19) cm2 molecule(-1), in excellent agreement with a prediction based on a projection of a high-resolution literature absorption spectrum onto the laser line width. The performance, i.e., accuracy and precision of measurement and matrix effects, of the new 405 nm thermal dissociation cavity ring-down spectrometer was evaluated and compared to that of a 532 nm thermal dissociation cavity ring-down spectrometer using laboratory-generated air samples. The new 405 nm spectrometer was considerably more sensitive and compact than the previously constructed version. The key advantage of laser thermal dissociation cavity ring-down spectroscopy is that the measurement can be considered absolute and does not need to rely on external calibration.

  15. Accurate radiocarbon age estimation using "early" measurements: a new approach to reconstructing the Paleolithic absolute chronology

    NASA Astrophysics Data System (ADS)

    Omori, Takayuki; Sano, Katsuhiro; Yoneda, Minoru

    2014-05-01

    This paper presents new correction approaches for "early" radiocarbon ages to reconstruct the Paleolithic absolute chronology. In order to discuss time-space distribution about the replacement of archaic humans, including Neanderthals in Europe, by the modern humans, a massive data, which covers a wide-area, would be needed. Today, some radiocarbon databases focused on the Paleolithic have been published and used for chronological studies. From a viewpoint of current analytical technology, however, the any database have unreliable results that make interpretation of radiocarbon dates difficult. Most of these unreliable ages had been published in the early days of radiocarbon analysis. In recent years, new analytical methods to determine highly-accurate dates have been developed. Ultrafiltration and ABOx-SC methods, as new sample pretreatments for bone and charcoal respectively, have attracted attention because they could remove imperceptible contaminates and derive reliable accurately ages. In order to evaluate the reliability of "early" data, we investigated the differences and variabilities of radiocarbon ages on different pretreatments, and attempted to develop correction functions for the assessment of the reliability. It can be expected that reliability of the corrected age is increased and the age applied to chronological research together with recent ages. Here, we introduce the methodological frameworks and archaeological applications.

  16. Neonatal intensive care: satisfaction measured from a parent's perspective.

    PubMed

    Conner, J M; Nelson, E C

    1999-01-01

    Health care systems today are complex, technically proficient, competitive, and market-driven. One outcome of this environment is the recent phenomenon in the health care field of "consumerism." Strong emphasis is placed on customer service, with organized efforts to understand, measure, and meet the needs of customers served. The purpose of this article is to describe the current understanding and measurement of parent needs and expectations with neonatal intensive care services from the time the expectant parents enter the health care system for the birth through the discharge process and follow-up care. Through literature review, 11 dimensions of care were identified as important to parents whose infants received neonatal intensive care: assurance, caring, communication, consistent information, education, environment, follow-up care, pain management, participation, proximity, and support. Five parent satisfaction questionnaires-the Parent Feedback Questionnaire, Neonatal Index of Parent Satisfaction, Inpatient Parent Satisfaction-Children's Hospital Minneapolis, Picker Institute-Inpatient Neonatal Intensive Care Unit Survey, and the Neonatal Intensive Care Unit-Parent Satisfaction Form-are critically reviewed for their ability to measure parent satisfaction within the framework of the neonatal care delivery process. An immense gap was found in our understanding about what matters most and when to parents going through the neonatal intensive care experience. Additional research is required to develop comprehensive parent satisfaction surveys that measure parent perceptions of neonatal care within the framework of the care delivery process. PMID:9917476

  17. ABSOLUTE BUNCH LENGTH MEASUREMENTS AT THE ALS BY INCOHERENTSYNCHROTRON RADIATION FLUCTUATION ANALYSIS

    SciTech Connect

    Sannibale, Fernando; Zolotorev, Max S.; Filippetto, Daniele; Stupakov, Gennady V.

    2007-06-22

    By analysing the pulse to pulse intensity fluctuations ofthe radiation emitted by a charge particle in the incoherent part of thespectrum, it is possible to extract information about the spatialdistribution of the beam. At the Advanced Light Source (ALS) of theLawrence Berkeley National Laboratory, we have developed and tested asimple scheme based on this principle that allows for the absolutemeasurement of the bunch length. A description of the method and theexperimental results are presented.

  18. Measurement of the absolute and differential cross sections for 7Li(γ, n0)6Li

    SciTech Connect

    W.A. Wurtz, R.E. Pywell, B.E. Norum, S. Kucuker, B.D. Sawatzky, H.R. Weller, M.W. Ahmed, S. Stave

    2011-10-01

    We have measured the cross section of the photoneutron reaction channel {sup 7}Li+{gamma}{yields}{sup 6}Li(g.s.)+n where the progeny nucleus is the ground state of {sup 6}Li. We obtained the absolute cross section at photon energies 10, 11, 12, 13, 15, 20, 25, 30, and 35 MeV and also the dependence of the cross section on polar angle for all but the highest photon energy. For the energies 10 to 15 MeV we were able to use linearly polarized photons to obtain the dependence of the cross section on the photon polarization.

  19. 3D absolute shape measurement of live rabbit hearts with a superfast two-frequency phase-shifting technique

    PubMed Central

    Wang, Yajun; Laughner, Jacob I.; Efimov, Igor R.; Zhang, Song

    2013-01-01

    This paper presents a two-frequency binary phase-shifting technique to measure three-dimensional (3D) absolute shape of beating rabbit hearts. Due to the low contrast of the cardiac surface, the projector and the camera must remain focused, which poses challenges for any existing binary method where the measurement accuracy is low. To conquer this challenge, this paper proposes to utilize the optimal pulse width modulation (OPWM) technique to generate high-frequency fringe patterns, and the error-diffusion dithering technique to produce low-frequency fringe patterns. Furthermore, this paper will show that fringe patterns produced with blue light provide the best quality measurements compared to fringe patterns generated with red or green light; and the minimum data acquisition speed for high quality measurements is around 800 Hz for a rabbit heart beating at 180 beats per minute. PMID:23482151

  20. Measurement of the absolute vμ-CCQE cross section at the SciBooNE experiment

    SciTech Connect

    Aunion, Jose Luis Alcaraz

    2010-07-01

    This thesis presents the measurement of the charged current quasi-elastic (CCQE) neutrino-nucleon cross section at neutrino energies around 1 GeV. This measurement has two main physical motivations. On one hand, the neutrino-nucleon interactions at few GeV is a region where existing old data are sparse and with low statistics. The current measurement populates low energy regions with higher statistics and precision than previous experiments. On the other hand, the CCQE interaction is the most useful interaction in neutrino oscillation experiments. The CCQE channel is used to measure the initial and final neutrino fluxes in order to determine the neutrino fraction that disappeared. The neutrino oscillation experiments work at low neutrino energies, so precise measurement of CCQE interactions are essential for flux measurements. The main goal of this thesis is to measure the CCQE absolute neutrino cross section from the SciBooNE data. The SciBar Booster Neutrino Experiment (SciBooNE) is a neutrino and anti-neutrino scattering off experiment. The neutrino energy spectrum works at energies around 1 GeV. SciBooNE was running from June 8th 2007 to August 18th 2008. In that period, the experiment collected a total of 2.65 x 1020 protons on target (POT). This thesis has used full data collection in neutrino mode 0.99 x 1020 POT. A CCQE selection cut has been performed, achieving around 70% pure CCQE sample. A fit method has been exclusively developed to determine the absolute CCQE cross section, presenting results in a neutrino energy range from 0.2 to 2 GeV. The results are compatible with the NEUT predictions. The SciBooNE measurement has been compared with both Carbon (MiniBoonE) and deuterium (ANL and BNL) target experiments, showing a good agreement in both cases.

  1. Absolute Beam Energy Measurement using Elastic ep Scattering at Thomas Jefferson National Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Deur, Alexandre

    1999-10-01

    The Jefferson Lab beam energy measurement in Hall A using the elastic ep scattering will be described. This new, non-magnetic, energy measurement method allows a ( triangle E/E=10-4 ) precision. First-order corrections are canceled by the measurements of the electron and proton scattering angles for two symmetric kinematics. The measurement principle will be presented as well as the device and measurement results. Comparison with independent magnetic energy measurements of the same accuracy will be shown. This project is the result of a collaboration between the LPC: université Blaise Pascal/in2p3), Saclay and Jefferson Lab.

  2. Absolute optical oscillator strengths for the electronic excitation of atoms at high resolution: Experimental methods and measurements for helium

    SciTech Connect

    Chan, W.F.; Cooper, G.; Brion, C.E. )

    1991-07-01

    An alternative method is described for the measurement of absolute optical oscillator strengths (cross sections) for electronic excitation of free atoms and molecules throughout the discrete region of the valence-shell spectrum at high energy resolution (full width at half maximum of 0.048 eV). The technique, utilizing the virtual-photon field of a fast electron inelastically scattered at negligible momentum transfer, avoids many of the difficulties associated with the various direct optical techniques that have traditionally been used for absolute optical oscillator strength measurements. The method is also free of the bandwidth (line saturation) effects that can seriously limit the accuracy of photoabsorption cross-section measurements for discrete transitions of narrow linewidth obtained using the Beer-Lambert law ({ital I}{sub 0}/{ital I}=exp({ital nl}{sigma}{sub {ital p}})). Since the line-saturation effects are not widely appreciated and are only usually considered in the context of peak heights, a detailed analysis of this problem is presented, with consideration of the integrated cross section (oscillator strength) over the profile of each discrete peak.

  3. A Novel Portable Absolute Transient Hot-Wire Instrument for the Measurement of the Thermal Conductivity of Solids

    NASA Astrophysics Data System (ADS)

    Assael, Marc J.; Antoniadis, Konstantinos D.; Metaxa, Ifigeneia N.; Mylona, Sofia K.; Assael, John-Alexander M.; Wu, Jiangtao; Hu, Miaomiao

    2015-11-01

    A new portable absolute Transient Hot-Wire instrument for measuring the thermal conductivity of solids over a range of 0.2 { W}{\\cdot }m^{-1}{\\cdot }{K}^{-1} to 4 { W}{\\cdot }m^{-1}{\\cdot }{K}^{-1} is presented. The new instrument is characterized by three novelties: (a) an innovative two-wires sensor which provides robustness and portability, while at the same time employs a soft silicone layer to eliminate the effect of the contact resistance between the wires and the sample, (b) a newly designed compact portable printed electronic board employing an FPGA architecture CPU to the control output voltage and data processing—the new board replaces the traditional, large in size Wheatstone-type bridge system required to perform the experimental measurements, and (c) a cutting-edge software suite, developed for the mesh describing the structure of the sensor, and utilizing the Finite Elements Method to model the heat flow. The estimation of thermal conductivity is modeled as a minimization problem and is solved using Bayesian Optimization. Our revolutionizing proposed methodology exhibits radical speedups of up to × 120, compared to previous approaches, and considerably reduces the number of simulations performed, achieving convergence only in a few minutes. The new instrument was successfully employed to measure, at room temperature, the thermal conductivity of two thermal conductivity reference materials, Pyroceram 9606 and Pyrex 7740, and two possible candidate glassy solids, PMMA and BK7, with an absolute low uncertainty of 2 %.

  4. Effect of self-vibration on accuracy of free-fall absolute gravity measurement with laser interferometer

    NASA Astrophysics Data System (ADS)

    Feng, Jin-yang; Wu, Shu-qing; Li, Chun-jian; Su, Duo-wu; Yu, Mei

    2015-02-01

    A free-fall absolute gravimeter was used to measure the gravity acceleration of a corner-cube released in high vacuum, and the gravity acceleration was determined by fitting the free-falling trajectories obtained through optical interferometry. During the measurement, the self-vibration of an absolute gravimeter caused ground vibration and the change in optical path length due to vibration of vacuum-air interface, which resulted in a measurement error. Numerical simulation was run by introducing vibration disturbance to the trajectories of free-fall. The effect of disturbance under different instrumental self-vibration conditions was analyzed. Simulation results indicated that the deviation of calculated gravity acceleration from the preset value and residuals amplitude after fitting depended on the amplitude and initial phase of the vibration disturbance. The deviation value and fitting residuals amplitude increased with the increasing of amplitude and there was a one-to-one correspondence between the two. The deviation of calculated gravity acceleration decreases by properly setting the initial phase difference of vibration disturbance with respect to the interference fringe signal.

  5. Numerical phase retrieval from beam intensity measurements in three planes

    NASA Astrophysics Data System (ADS)

    Bruel, Laurent

    2003-05-01

    A system and method have been developed at CEA to retrieve phase information from multiple intensity measurements along a laser beam. The device has been patented. Commonly used devices for beam measurement provide phase and intensity information separately or with a rather poor resolution whereas the MIROMA method provides both at the same time, allowing direct use of the results in numerical models. Usual phase retrieval algorithms use two intensity measurements, typically the image plane and the focal plane (Gerschberg-Saxton algorithm) related by a Fourier transform, or the image plane and a lightly defocus plane (D.L. Misell). The principal drawback of such iterative algorithms is their inability to provide unambiguous convergence in all situations. The algorithms can stagnate on bad solutions and the error between measured and calculated intensities remains unacceptable. If three planes rather than two are used, the data redundancy created confers to the method good convergence capability and noise immunity. It provides an excellent agreement between intensity determined from the retrieved phase data set in the image plane and intensity measurements in any diffraction plane. The method employed for MIROMA is inspired from GS algorithm, replacing Fourier transforms by a beam-propagating kernel with gradient search accelerating techniques and special care for phase branch cuts. A fast one dimensional algorithm provides an initial guess for the iterative algorithm. Applications of the algorithm on synthetic data find out the best reconstruction planes that have to be chosen. Robustness and sensibility are evaluated. Results on collimated and distorted laser beams are presented.

  6. [Physical meaning of temperature measured by spectral line intensity method].

    PubMed

    Zhao, Wen-Hua; Tang, Huang-Zai; Shen, Yan; Shi, Yong; Hou, Ling-Yun

    2007-11-01

    The difference between electron temperature and excitation temperature is analyzed in the aspect of statistics thermodynamics. It is presented clearly that the temperature acquired by spectral line intensity method is not free electron temperature, but internal electronic excitation temperature of heavy particle. Under thermal equilibrium condition, the excitation temperature is equal to the electron temperature, while under non-thermal equilibrium condition, the excitation temperature is not equal to the electron temperature. In the study of arc jet plume in vacuum chamber, spectral line intensity method was employed to measure the apparent excitation temperature of arc jet plume, and Langmuir probe was employed to measure the electron temperature of arcjet plume. The big difference between the excitation temperature and the electron temperature proved that the temperature acquired by spectral line intensity method is not free electron temperature.

  7. Selected methods of measuring workload among intensive care nursing staff.

    PubMed

    Kwiecień, Katarzyna; Wujtewicz, Maria; Mędrzycka-Dąbrowska, Wioletta

    2012-06-01

    Intensive care units and well-qualified medical staff are indispensable for the proper functioning of every hospital facility. Due to demographic changes and technological progress having extended the average life expectancy, the number of patients hospitalized in intensive care units increases every year [9,10]. Global shortages of nursing staff (including changes in their age structure) have triggered a debate on the working environment and workload the nursing staff are exposed to while performing their duties. This paper provides a critical review of selected methods for the measurement of the workload of intensive care nurses and points out their practical uses. The paper reviews Polish and foreign literature on workload and the measurement tools used to evaluate workload indicators.

  8. Measurement and simulation of ICRF wave intensity with a recalibrated phase contrast imaging diagnostic on Alcator C-Mod

    NASA Astrophysics Data System (ADS)

    Tsujii, N.; Porkolab, M.; Bonoli, P. T.; Edlund, E. M.; Ennever, P. C.; Lin, Y.; Wright, J. C.; Wukitch, S. J.; Jaeger, E. F.; Green, D. L.; Harvey, R. W.

    2015-12-01

    Waves in the ion cyclotron range of frequencies (ICRF) are one of the major tools to heat fusion plasmas. Full-wave simulations are essential to predict the wave propagation and absorption quantitatively, and it is important that these codes be validated against actual experimental measurements. In this work, the absolute intensity of the ICRF waves previously measured with a phase contrast imaging diagnostic was recalibrated and compared once more with full-wave predictions. In the earlier work, significant discrepancies were found between the measured and the simulated mode converted wave intensity [N. Tsujii et al., Phys. Plasmas 19, 082508]. With the new calibration of the detector array, the measured mode converted wave intensity is now in much better agreement with the full-wave predictions. The agreement is especially good for comparisons performed close to the antenna.

  9. Measurement and simulation of ICRF wave intensity with a recalibrated phase contrast imaging diagnostic on Alcator C-Mod

    SciTech Connect

    Tsujii, N.; Porkolab, M.; Bonoli, P. T.; Edlund, E. M.; Ennever, P. C.; Lin, Y.; Wright, J. C.; Wukitch, S. J.; Jaeger, E. F.; Green, D. L.; Harvey, R. W.

    2015-12-10

    Waves in the ion cyclotron range of frequencies (ICRF) are one of the major tools to heat fusion plasmas. Full-wave simulations are essential to predict the wave propagation and absorption quantitatively, and it is important that these codes be validated against actual experimental measurements. In this work, the absolute intensity of the ICRF waves previously measured with a phase contrast imaging diagnostic was recalibrated and compared once more with full-wave predictions. In the earlier work, significant discrepancies were found between the measured and the simulated mode converted wave intensity [N. Tsujii et al., Phys. Plasmas 19, 082508]. With the new calibration of the detector array, the measured mode converted wave intensity is now in much better agreement with the full-wave predictions. The agreement is especially good for comparisons performed close to the antenna.

  10. Absolute prompt-gamma yield measurements for ion beam therapy monitoring.

    PubMed

    Pinto, M; Bajard, M; Brons, S; Chevallier, M; Dauvergne, D; Dedes, G; De Rydt, M; Freud, N; Krimmer, J; La Tessa, C; Létang, J M; Parodi, K; Pleskač, R; Prieels, D; Ray, C; Rinaldi, I; Roellinghoff, F; Schardt, D; Testa, E; Testa, M

    2015-01-21

    Prompt-gamma emission detection is a promising technique for hadrontherapy monitoring purposes. In this regard, obtaining prompt-gamma yields that can be used to develop monitoring systems based on this principle is of utmost importance since any camera design must cope with the available signal. Herein, a comprehensive study of the data from ten single-slit experiments is presented, five consisting in the irradiation of either PMMA or water targets with lower and higher energy carbon ions, and another five experiments using PMMA targets and proton beams. Analysis techniques such as background subtraction methods, geometrical normalization, and systematic uncertainty estimation were applied to the data in order to obtain absolute prompt-gamma yields in units of prompt-gamma counts per incident ion, unit of field of view, and unit of solid angle. At the entrance of a PMMA target, where the contribution of secondary nuclear reactions is negligible, prompt-gamma counts per incident ion, per millimetre and per steradian equal to (124 ± 0.7stat ± 30sys) × 10(-6) for 95 MeV u(-1) carbon ions, (79 ± 2stat ± 23sys) × 10(-6) for 310 MeV u(-1) carbon ions, and (16 ± 0.07stat ± 1sys) × 10(-6) for 160 MeV protons were found for prompt gammas with energies higher than 1 MeV. This shows a factor 5 between the yields of two different ions species with the same range in water (160 MeV protons and 310 MeV u(-1) carbon ions). The target composition was also found to influence the prompt-gamma yield since, for 300/310 MeV u(-1) carbon ions, a 42% greater yield ((112 ± 1stat ± 22sys) × 10(-6) counts ion(-1) mm(-1) sr(-1)) was obtained with a water target compared to a PMMA one. PMID:25548833

  11. Measurements of absolute delayed neutron yield and group constants in the fast fission of {sup 235}U and {sup 237}Np

    SciTech Connect

    Loaiza, D.J.; Brunson, G.; Sanchez, R.; Butterfield, K.

    1998-03-01

    The delayed neutron activity resulting from the fast induced fission of {sup 235}U and {sup 237}Np has been studied. The six-group decay constants, relative abundances, and absolute yield of delayed neutrons from fast fission of {sup 235}U and {sup 237}Np were measured using the Godiva IV fast assembly at the Los Alamos Critical Experiments Facility. The absolute yield measured for {sup 235}U was 0.0163 {+-} 0.0008 neutron/fission. This value compares very well with the well-established Keepin absolute yield of 0.0165 {+-} 0.0005. The absolute yield value measured for {sup 237}Np was 0.0126 {+-} 0.0007. The measured delayed neutron parameters for {sup 235}U are corroborated with period (e-folding time) versus reactivity calculations.

  12. Calibration of the Odyssey Photosynthetic Irradiance Recorder for Absolute Irradiance Measures

    EPA Science Inventory

    Researchers are increasingly interested in measuring hotosynthetically active radiation (PAR) because of its importance in determining the structure and function of lotic ecosystems. The Odyssey Photosynthetic Irradiance Recorder is an affordable PAR meter gaining popularity am...

  13. Wave intensity wall analysis: a novel noninvasive method to measure wave intensity.

    PubMed

    Larsson, Matilda; Bjällmark, Anna; Lind, Britta; Balzano, Rita; Peolsson, Michael; Winter, Reidar; Brodin, Lars-Ake

    2009-09-01

    Wave intensity analysis is a concept providing information about the interaction of the heart and the vascular system. Originally, the technique was invasive. Since then new noninvasive methods have been developed. A recently developed ultrasound technique to estimate tissue motion and deformation is speckle-tracking echocardiography. Speckle tracking-based techniques allow for accurate measurement of movement and deformation variables in the arterial wall in both the radial and the longitudinal direction. The aim of this study was to test if speckle tracking-derived deformation data could be used as input for wave intensity calculations. The new concept was to approximate changes of flow and pressure by deformation changes of the arterial wall in longitudinal and radial directions. Flow changes (dU/dt) were approximated by strain rate (sr, 1/s) of the arterial wall in the longitudinal direction, whereas pressure changes (dP/dt) were approximated by sign reversed strain rate (1/s) in the arterial wall in the radial direction. To validate the new concept, a comparison between the newly developed Wave Intensity Wall Analysis (WIWA) algorithm and a commonly used and validated wave intensity system (SSD-5500, Aloka, Tokyo, Japan) was performed. The studied population consisted of ten healthy individuals (three women, seven men) and ten patients (all men) with coronary artery disease. The present validation study indicates that the mechanical properties of the arterial wall, as measured by a speckle tracking-based technique are a possible input for wave intensity calculations. The study demonstrates good visual agreement between the two systems and the time interval between the two positive peaks (W1-W2) measured by the Aloka system and the WIWA system correlated for the total group (r = 0.595, P < 0.001). The correlation for the diseased subgroup was r = 0.797, P < 0.001 and for the healthy subgroup no significant correlation was found (P > 0.05). The results of the

  14. Solid-state track recorder dosimetry device to measure absolute reaction rates and neutron fluence as a function of time

    DOEpatents

    Gold, Raymond; Roberts, James H.

    1989-01-01

    A solid state track recording type dosimeter is disclosed to measure the time dependence of the absolute fission rates of nuclides or neutron fluence over a period of time. In a primary species an inner recording drum is rotatably contained within an exterior housing drum that defines a series of collimating slit apertures overlying windows defined in the stationary drum through which radiation can enter. Film type solid state track recorders are positioned circumferentially about the surface of the internal recording drum to record such radiation or its secondary products during relative rotation of the two elements. In another species both the recording element and the aperture element assume the configuration of adjacent disks. Based on slit size of apertures and relative rotational velocity of the inner drum, radiation parameters within a test area may be measured as a function of time and spectra deduced therefrom.

  15. Absolute Rb one-color two-photon ionization cross-section measurement near a quantum interference

    SciTech Connect

    Takekoshi, T.; Brooke, G.M.; Patterson, B.M.; Knize, R.J.

    2004-05-01

    We observe destructive interference in the ground-state Rb two-photon ionization cross section when the single photon energy is tuned between the 5S{yields}5P and 5S{yields}6P transition energies. The minimum cross section is 5.9(1.5)x10{sup -52} cm{sup 4} s and it occurs at a wavelength of 441.0(3) nm (in vacuo). Relative measurements of these cross sections are made at various wavelengths by counting ions produced when magneto-optically trapped Rb atoms are exposed to light from a tunable pulsed laser. This relative curve is calibrated to an absolute cross-section measurement at 532 nm using the trap loss method. A simple calculation agrees reasonably with our results.

  16. Absolute depth-dose-rate measurements for an {sup 192}Ir HDR brachytherapy source in water using MOSFET detectors

    SciTech Connect

    Zilio, Valery Olivier; Joneja, Om Parkash; Popowski, Youri; Rosenfeld, Anatoly; Chawla, Rakesh

    2006-06-15

    Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an {sup 192}Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are presented and special attention is paid to the calibration of the R and K type detectors, and to the determination of appropriate correction factors for the sensitivity variation with the increase of the threshold voltage and the energy dependence. The experimental results are compared with Monte Carlo simulated dose rate distributions. The experimental results show a good agreement with the Monte Carlo simulations: the discrepancy between experimental and Monte Carlo results being within 5% for 82% of the points and within 10% for 95% of the points. Moreover, all points except two are found to lie within the experimental uncertainties, confirming thereby the quality of the results obtained.

  17. TU-A-12A-09: Absolute Blood Flow Measurement in a Cardiac Phantom Using Low Dose CT

    SciTech Connect

    Ziemer, B; Hubbard, L; Lipinski, J; Molloi, S

    2014-06-15

    Purpose: To investigate a first pass analysis technique to measure absolute flow from low dose CT images in a cardiac phantom. This technique can be combined with a myocardial mass assignment to yield absolute perfusion using only two volume scans and reduce the radiation dose to the patient. Methods: A four-chamber cardiac phantom and perfusion chamber were constructed from poly-acrylic and connected with tubing to approximate anatomical features. The system was connected to a pulsatile pump, input/output reservoirs and power contrast injector. Flow was varied in the range of 1-2.67 mL/s with the pump operating at 60 beats/min. The system was imaged once a second for 14 seconds with a 320-row scanner (Toshiba Medical Systems) using a contrast-enhanced, prospective-gated cardiac perfusion protocol. Flow was calculated by the following steps: subsequent images of the perfusion volume were subtracted to find the contrast entering the volume; this was normalized by an upstream, known volume region to convert Hounsfield (HU) values to concentration; this was divided by the subtracted images time difference. The technique requires a relatively stable input contrast concentration and no contrast can leave the perfusion volume before the flow measurement is completed. Results: The flow calculated from the images showed an excellent correlation with the known rates. The data was fit to a linear function with slope 1.03, intercept 0.02 and an R{sup 2} value of 0.99. The average root mean square (RMS) error was 0.15 mL/s and the average standard deviation was 0.14 mL/s. The flow rate was stable within 7.7% across the full scan and served to validate model assumptions. Conclusion: Accurate, absolute flow rates were measured from CT images using a conservation of mass model. Measurements can be made using two volume scans which can substantially reduce the radiation dose compared with current dynamic perfusion techniques.

  18. Research on temperature measurement technology for graphite-cone-absorption-cavity absolute calorimeter

    NASA Astrophysics Data System (ADS)

    Wei, Ji Feng; Lu, Fei; Sun, Li Qun; Zhang, Kai; Hu, Xiao Yang; Zhou, Shan; Xu, De

    2015-02-01

    The nonlinear effect of materials and sensors in high-energy laser calorimeters is especially obvious—due to the steep temperature gradients of their absorbers. Significant measurement errors occur when traditional integral temperature sensors and methods are utilized. In an effort to remedy this, a method is proposed in this paper in which an absorption cavity is divided into many parts and multiple discrete thermocouple sensors are used to measure the temperature rise of the absorbers. The temperature distribution in the absorbers is theoretically analyzed, numerically simulated, and verified through experimentation. Energy measurement results are compared according to the temperature distribution for different layouts of thermocouples. A high-accuracy calorimeter is developed by setting and optimizing thermocouple layout, as well as correcting various elements such as the specific heat of graphite and responsivity of thermocouples. The calorimeter employing this measurement method is calibrated against a standard energy meter, resulting in correction coefficient of 1.027 and relative standard deviation of the correction coefficient of only 0.8%. Theoretical analysis, numerical simulation, and experimental verification all prove that the proposed method successfully improves measurement accuracy.

  19. Research on temperature measurement technology for graphite-cone-absorption-cavity absolute calorimeter.

    PubMed

    Wei, Ji Feng; Lu, Fei; Sun, Li Qun; Zhang, Kai; Hu, Xiao Yang; Zhou, Shan; Xu, De

    2015-02-01

    The nonlinear effect of materials and sensors in high-energy laser calorimeters is especially obvious-due to the steep temperature gradients of their absorbers. Significant measurement errors occur when traditional integral temperature sensors and methods are utilized. In an effort to remedy this, a method is proposed in this paper in which an absorption cavity is divided into many parts and multiple discrete thermocouple sensors are used to measure the temperature rise of the absorbers. The temperature distribution in the absorbers is theoretically analyzed, numerically simulated, and verified through experimentation. Energy measurement results are compared according to the temperature distribution for different layouts of thermocouples. A high-accuracy calorimeter is developed by setting and optimizing thermocouple layout, as well as correcting various elements such as the specific heat of graphite and responsivity of thermocouples. The calorimeter employing this measurement method is calibrated against a standard energy meter, resulting in correction coefficient of 1.027 and relative standard deviation of the correction coefficient of only 0.8%. Theoretical analysis, numerical simulation, and experimental verification all prove that the proposed method successfully improves measurement accuracy. PMID:25725875

  20. Absolute Thickness Measurements on Coatings Without Prior Knowledge of Material Properties Using Terahertz Energy

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Cosgriff, Laura M.; Harder, Bryan; Zhu, Dongming; Martin, Richard E.

    2013-01-01

    This study investigates the applicability of a novel noncontact single-sided terahertz electromagnetic measurement method for measuring thickness in dielectric coating systems having either dielectric or conductive substrate materials. The method does not require knowledge of the velocity of terahertz waves in the coating material. The dielectric coatings ranged from approximately 300 to 1400 m in thickness. First, the terahertz method was validated on a bulk dielectric sample to determine its ability to precisely measure thickness and density variation. Then, the method was studied on simulated coating systems. One simulated coating consisted of layered thin paper samples of varying thicknesses on a ceramic substrate. Another simulated coating system consisted of adhesive-backed Teflon adhered to conducting and dielectric substrates. Alumina samples that were coated with a ceramic adhesive layer were also investigated. Finally, the method was studied for thickness measurement of actual thermal barrier coatings (TBC) on ceramic substrates. The unique aspects and limitations of this method for thickness measurements are discussed.

  1. Absolute perfusion measurements and associated iodinated contrast agent time course in brain metastasis: a study for contrast-enhanced radiotherapy.

    PubMed

    Obeid, Layal; Deman, Pierre; Tessier, Alexandre; Balosso, Jacques; Estève, François; Adam, Jean-François

    2014-04-01

    Contrast-enhanced radiotherapy is an innovative treatment that combines the selective accumulation of heavy elements in tumors with stereotactic irradiations using medium energy X-rays. The radiation dose enhancement depends on the absolute amount of iodine reached in the tumor and its time course. Quantitative, postinfusion iodine biodistribution and associated brain perfusion parameters were studied in human brain metastasis as key parameters for treatment feasibility and quality. Twelve patients received an intravenous bolus of iodinated contrast agent (CA) (40 mL, 4 mL/s), followed by a steady-state infusion (160 mL, 0.5 mL/s) to ensure stable intratumoral amounts of iodine during the treatment. Absolute iodine concentrations and quantitative perfusion maps were derived from 40 multislice dynamic computed tomography (CT) images of the brain. The postinfusion mean intratumoral iodine concentration (over 30 minutes) reached 1.94 ± 0.12 mg/mL. Reasonable correlations were obtained between these concentrations and the permeability surface area product and the cerebral blood volume. To our knowledge, this is the first quantitative study of CA biodistribution versus time in brain metastasis. The study shows that suitable and stable amounts of iodine can be reached for contrast-enhanced radiotherapy. Moreover, the associated perfusion measurements provide useful information for the patient recruitment and management processes.

  2. Spent fuel burnup estimation by Cerenkov glow intensity measurement

    SciTech Connect

    Kuribara, Masayuki . Communication and Information Research Lab.)

    1994-10-01

    The Cerenkov glow images from irradiated fuel assemblies of boiling-water reactors (BWR) and pressurized-water reactors (PWR) are generally used for inspections. For this purpose, a new UV-I.I. CVD (ultra-violet light image intensifier Cerenkov viewing device), has been developed. This new device can measure the intensity of the Cerenkov glow from a spent fuel assembly, thus making it possible to estimate the burnup of the fuel assembly by comparing the Cerenkov glow intensity to the reference intensity. The experiment was carried out on BWR spent fuel assemblies and the results show that burnups are estimated within 20% accuracy compared to the declared burnups for the tested spent fuel assemblies for cooling times ranging from 900--2.000 d.

  3. Resolving Differences in Absolute Irradiance Measurements Between the SOHO/CELIAS/SEM and the SDO/EVE

    NASA Astrophysics Data System (ADS)

    Wieman, S. R.; Didkovsky, L. V.; Judge, D. L.

    2014-08-01

    The Solar EUV Monitor (SEM) onboard SOHO has measured absolute extreme ultraviolet (EUV) and soft X-ray solar irradiance nearly continuously since January 1996. The EUV Variability Experiment (EVE) on SDO, in operation since April of 2010, measures solar irradiance in a wide spectral range that encompasses the band passes (26 - 34 nm and 0.1 - 50 nm) measured by SOHO/SEM. However, throughout the mission overlap, irradiance values from these two instruments have differed by more than the combined stated uncertainties of the measurements. In an effort to identify the sources of these differences and eliminate them, we investigate in this work the effect of reprocessing the SEM data using a more accurate SEM response function (obtained from synchrotron measurements with a SEM sounding-rocket clone instrument taken after SOHO was already in orbit) and time-dependent, measured solar spectral distributions - i.e., solar reference spectra that were unavailable prior to the launch of the SDO. We find that recalculating the SEM data with these improved parameters reduces mean differences with the EVE measurements from about 20 % to less than 5 % in the 26 - 34 nm band, and from about 35 % to about 15 % for irradiances in the 0.1 - 7 nm band extracted from the SEM 0.1 - 50 nm channel.

  4. A new method for the absolute radiance calibration for UV/vis measurements of scattered sun light

    NASA Astrophysics Data System (ADS)

    Wagner, T.; Beirle, S.; Dörner, S.; Penning de Vries, M.; Remmers, J.; Rozanov, A.; Shaiganfar, R.

    2015-05-01

    Absolute radiometric calibrations are important for measurements of the atmospheric spectral radiance. Such measurements can be used to determine actinic fluxes, the properties of aerosols and clouds and the short wave energy budget. Conventional calibration methods in the laboratory are based on calibrated light sources and reflectors and are expensive, time consuming and subject to relatively large uncertainties. Also, the calibrated instruments might change during transport from the laboratory to the measurement sites. Here we present a new calibration method for UV/vis instruments that measure the spectrally resolved sky radiance, like for example zenith sky Differential Optical Absorption Spectroscopy (DOAS-) instruments or Multi-AXis (MAX-) DOAS instruments. Our method is based on the comparison of the solar zenith angle dependence of the measured zenith sky radiance with radiative transfer simulations. For the application of our method clear sky measurements during periods with almost constant aerosol optical depth are needed. The radiative transfer simulations have to take polarisation into account. We show that the calibration results are almost independent from the knowledge of the aerosol optical properties and surface albedo, which causes a rather small uncertainty of about <7%. For wavelengths below about 330 nm it is essential that the ozone column density during the measurements is constant and known.

  5. Absolute Measurement of Lattice Spacing d(220) in Floating Zone Silicon Crystal

    NASA Astrophysics Data System (ADS)

    Fujimoto, Hiroyuki; Nakayama, Kan; Tanaka, Mitsuru; Misawa, Guento

    1995-09-01

    The lattice spacing d220 of a silicon crystal of National Research Laboratory of Metrology has been measured with a new combined X-ray and optical interferometer, with relative uncertainty of 0.16 ppm. This value is in good agreement with other reported values, whereas the ratio of molar mass M to density ρ measured for this crystal shows discrepancy of around 3 ppm from previously reported ratios. It seems that the conventional route to determining the Avogadro constant from M, ρ and d220 will require a new characterization technique to estimate the number of silicon atoms in a unit cell volume.

  6. Measurement of absolute diffraction efficiency of a variable line spaced grating using reflectivity beamline

    SciTech Connect

    Kumar, M.; Modi, M. H.; Singhal, H.; Chakera, J. A.; Gupta, R. K.; Naik, P. A.; Lodha, G. S.; Gupta, P. D.

    2012-06-05

    First and second order diffraction efficiency of a variable line spacing grating of average 1200 lines/mm density is measured at the reflectivity beam line of Indus-1. This grating is blazed at 3.2 deg. and has a blaze wavelength of 10 nm. The measurement has been carried out in the spectral range of 4.5 nm to 80 nm at 3o grazing angle of incidence. The maximum diffraction efficiency of the first order at {approx}10 nm has been found to be {approx} 23% and for the second order it is {approx}13%.

  7. Validation of short-pulse-laser-based measurement setup for absolute spectral irradiance responsivity calibration.

    PubMed

    Schuster, Michaela; Nevas, Saulius; Sperling, Armin

    2014-05-01

    This paper describes the validation process of mode-locked lasers in the "tunable lasers in photometry" (TULIP) setup at Physikalisch-Technische Bundesanstalt (PTB) regarding spectral irradiance responsivity calibrations. Validation has been carried out in the visible spectral range, 400-700 nm, with two different photometer heads and in the long wavelength range, 690-780 nm, with a filtered radiometer. A comparison of the results against those from two different validated measurement setups has been carried out for validation. For the visible spectral range, the comparison is conducted against the data obtained from a lamp-based monochromator setup for spectral irradiance responsivity calibrations and against the photometric values (integral quantity) measured at the photometric bench setup of PTB. For the long wavelength range, comparisons against results from two different lamp-based monochromator measurement setups were made. Additionally, the effect of different radiation bandwidths on interference oscillations has been determined for a filter radiometer without a diffuser. A procedure for the determination of the optimum bandwidth of the setup for the respective measurement device is presented. PMID:24921865

  8. Measurement of muscle strength in the intensive care unit.

    PubMed

    Bittner, Edward A; Martyn, Jeevendra A; George, Edward; Frontera, Walter R; Eikermann, Matthias

    2009-10-01

    Traditional (indirect) techniques, such as electromyography and nerve conduction velocity measurement, do not reliably predict intensive care unit-acquired muscle weakness and its clinical consequences. Therefore, quantitative assessment of skeletal muscle force is important for diagnosis of intensive care unit-acquired motor dysfunction. There are a number of ways for assessing objectively muscle strength, which can be categorized as techniques that quantify maximum voluntary contraction force and those that assess evoked (stimulated) muscle force. Important factors that limit the repetitive evaluation of maximum voluntary contraction force in intensive care unit patients are learning effects, pain during muscular contraction, and alteration of consciousness.The selection of the appropriate muscle is crucial for making adequate predictions of a patient's outcome. The upper airway dilators are much more susceptible to a decrease in muscle strength than the diaphragm, and impairment of upper airway patency is a key mechanism of extubation failure in intensive care unit patients. Data suggest that the adductor pollicis muscle is an appropriate reference muscle to predict weakness of muscles that are typically affected by intensive care unit-acquired weakness, i.e., upper airway as well as extremity muscles. Stimulated (evoked) force of skeletal muscles, such as the adductor pollicis, can be assessed repetitively, independent of brain function, even in heavily sedated patients during high acuity of their disease. PMID:20046117

  9. Optimal locations for absolute gravity measurements and sensitivity of GRACE observations for constraining glacial isostatic adjustment on the northern hemisphere

    NASA Astrophysics Data System (ADS)

    Steffen, Holger; Wu, Patrick; Wang, Hansheng

    2012-09-01

    Gravity rate of change is an important quantity in the investigation of glacial isostatic adjustment (GIA). However, measurements with absolute and relative gravimeters are laborious and time-consuming, especially in the vast GIA-affected regions of high latitudes with insufficient infrastructure. Results of the Gravity Recovery And Climate Experiment (GRACE) satellite mission have thus provided tremendous new insight as they fully cover those areas. To better constrain the GIA model (i.e. improve the glaciation history and Earth parameters) with new gravity data, we analyse the currently determined errors in gravity rate of change from absolute gravity (AG) and GRACE measurements in North America and Fennoscandia to test their sensitivity for different ice models, lithospheric thickness, background viscosity and lateral mantle viscosity variations. We provide detailed sensitivity maps for these four parameters and highlight areas that need more AG measurements to further improve our understanding of GIA. The best detectable parameter with both methods in both regions is the sensitivity to ice model changes, which covers large areas in the sensitivity maps. Also, most of these areas are isolated from sensitive areas of the other three parameters. The latter mainly overlap with ice model sensitivity and each other. Regarding existing AG stations, more stations are strongly needed in northwestern and Arctic Canada. In contrast, a quite dense network of stations already exists in Fennoscandia. With an extension to a few sites in northwestern Russia, a complete station network is provided to study the GIA parameters. The data of dense networks would yield a comprehensive picture of gravity change, which can be further used for studies of the Earth's interior and geodynamic processes.

  10. Usability of a Fourier transform spectroradiometer for absolute surface spectral solar UV irradiance measurements.

    PubMed

    Meindl, Peter; Wähmer, Martin; Monte, Christian

    2014-10-20

    The suitability of a commercially available Fourier transform spectrometer equipped with a fiber-coupled global entrance optic as a reference spectroradiometer for the measurement of spectral solar ultraviolet irradiance at ground level has been investigated. The instrument has been characterized with respect to the wavelength uncertainty, and a calibration of the spectral irradiance responsivity has been performed by using the calculable irradiance of a high temperature black-body radiator and by using a secondary irradiance standard lamp. The relative standard uncertainty of solar irradiance measurements in the wavelength range from 310 nm to 400 nm with this spectroradiometer, based on the described methodology, is 1.6% for solar zenith angles of less than 60°.

  11. Usability of a Fourier transform spectroradiometer for absolute surface spectral solar UV irradiance measurements.

    PubMed

    Meindl, Peter; Wähmer, Martin; Monte, Christian

    2014-10-20

    The suitability of a commercially available Fourier transform spectrometer equipped with a fiber-coupled global entrance optic as a reference spectroradiometer for the measurement of spectral solar ultraviolet irradiance at ground level has been investigated. The instrument has been characterized with respect to the wavelength uncertainty, and a calibration of the spectral irradiance responsivity has been performed by using the calculable irradiance of a high temperature black-body radiator and by using a secondary irradiance standard lamp. The relative standard uncertainty of solar irradiance measurements in the wavelength range from 310 nm to 400 nm with this spectroradiometer, based on the described methodology, is 1.6% for solar zenith angles of less than 60°. PMID:25401540

  12. A new method for measuring absolute total electron-impact cross sections with forward scattering corrections

    SciTech Connect

    Ma, C.; Liescheski, P.B.; Bonham, R.A. )

    1989-12-01

    In this article we describe an experimental technique to measure the total electron-impact cross section by measurement of the attenuation of an electron beam passing through a gas at constant pressure with the unwanted forward scattering contribution removed. The technique is based on the different spatial propagation properties of scattered and unscattered electrons. The correction is accomplished by measuring the electron beam attenuation dependence on both the target gas pressure (number density) and transmission length. Two extended forms of the Beer--Lambert law which approximately include the contributions for forward scattering and for forward scattering plus multiple scattering from the gas outside the electron beam were developed. It is argued that the dependence of the forward scattering on the path length through the gas is approximately independent of the model used to describe it. The proposed methods were used to determine the total cross section and forward scattering contribution from argon (Ar) with 300-eV electrons. Our results are compared with those in the literature and the predictions of theory and experiment for the forward scattering and multiple scattering contributions. In addition, Monte Carlo simulations were performed as a further test of the method.

  13. Absolute measurements of x-ray backlighter sources at energies above 10 keV

    SciTech Connect

    Maddox, B. R.; Park, H. S.; Remington, B. A.; Chen, C.; Chen, S.; Prisbrey, S. T.; Comley, A.; Back, C. A.; Szabo, C.; Seely, J. F.; Feldman, U.; Hudson, L. T.; Seltzer, S.; Haugh, M. J.; Ali, Z.

    2011-05-15

    Line emission and broadband x-ray sources with x-ray energies above 10 keV have been investigated using a range of calibrated x-ray detectors for use as x-ray backlighters in high energy density (HED) experiments. The conversion efficiency of short- and long-pulse driven Mo and Ag line-emission backlighters at 17 and 22 keV was measured to investigate the crossover region between short- and long-pulse conversion efficiency. It was found that significant 17 and 22 keV line emissions were observed using a 3 {omega}, 1 ns long-pulse drive for Mo and Ag targets and a comparison between the measured Mo x-ray spectrum and calculations using an atomic physics code suggests that the line emission is due to thermal emission from N-like Mo atoms. Electron temperatures derived from fits to the continuum region of the x-ray spectra agree well with the T{sub hot} scaling as 100x(I{lambda}{sup 2}){sup 1/3}. The continuum emissions from empty and 1 atm Kr-filled imploded CH shell targets were also measured for the use as broadband backlighters.

  14. Regularity of absolutely continuous invariant measures for piecewise expanding unimodal maps

    NASA Astrophysics Data System (ADS)

    Contreras, Fabián; Dolgopyat, Dmitry

    2016-09-01

    Let f:[0,1]\\to [0,1] be a piecewise expanding unimodal map of class C  k+1, with k≥slant 1 , and μ =ρ \\text{d}x the (unique) SRB measure associated to it. We study the regularity of ρ. In particular, points N where ρ is not differentiable has zero Hausdorff dimension, but is uncountable if the critical orbit of f is dense. This improves on a work of Szewc (1984). We also obtain results about higher orders of differentiability of ρ in the sense of Whitney.

  15. Solar rotation measurements at Mount Wilson. II - Systematic instrumental effects and the absolute rotation rate

    NASA Technical Reports Server (NTRS)

    Labonte, B. J.; Howard, R.

    1981-01-01

    Possible sources of systematic error in solar Doppler rotational velocities are examined. Scattered light is shown to affect the Mount Wilson solar rotation results, but this effect is not enough to bring the spectroscopic results in coincidence with the sunspot rotation. Interference fringes at the spectrograph focus at Mount Wilson have in two intervals affected the rotation results. It has been possible to correlate this error with temperature and thus correct for it. A misalignment between the entrance and exit slits is a possible source of error, but for the Mount Wilson slit configuration, the amplitude of this effect is negligibly small. Rapid scanning of the solar image also produces no measurable effect.

  16. Measuring the absolute carrier-envelope phase of many-cycle laser fields

    SciTech Connect

    Tzallas, P.; Skantzakis, E.; Charalambidis, D.

    2010-12-15

    The carrier-envelope phase (CEP) of high-peak-power, many-cycle laser fields becomes a crucial parameter when such fields are used, in conjunction with polarization gating techniques, in isolated attosecond (asec) pulse generation. However, its measurement has not been achieved so far. We demonstrate a physical process sensitive to the CEP value of such fields and describe a method for its online shot-to-shot monitoring. This work paves the way for the exploitation of energetic isolated asec pulses in studies of nonlinear extreme ultraviolet (XUV) processes and XUV-pump-XUV-probe experiments with asec resolutions.

  17. Absolute np and pp Cross Section Determinations Aimed At Improving The Standard For Cross Section Measurements

    SciTech Connect

    Laptev, A. B.; Haight, R. C.; Tovesson, F.; Arndt, R. A.; Briscoe, W. J.; Paris, M. W.; Strakovsky, I. I.; Workman, R. L.

    2011-06-01

    Purpose of present research is a keeping improvement of the standard for cross section measurements of neutron-induced reactions. The cross sections for np and pp scattering below 1 GeV are determined based on partial-wave analyses (PWAs) of nucleon-nucleon scattering data. These cross sections are compared with the most recent ENDF/B-VII.0 and JENDL-4.0 data files, and the Nijmegen PWA. Also a comparison of evaluated data with recent experimental data was made to check a quality of evaluation. Excellent agreement was found between the new experimental data and our PWA predictions.

  18. Absolute np and pp cross section determinations aimed at improving the standard for cross section measurements

    SciTech Connect

    Laptev, Alexander B; Haight, Robert C; Tovesson, Fredrik; Arndt, Richard A; Briscoe, William J; Paris, Mark W; Strakovsky, Igor I; Workman, Ron L

    2010-01-01

    Purpose of present research is a keeping improvement of the standard for cross section measurements of neutron-induced reactions. The cross sections for np and pp scattering below 1000 MeV are determined based on partial-wave analyses (PW As) of nucleon-nucleon scattering data. These cross sections are compared with the most recent ENDF/B-V11.0 and JENDL-4.0 data files, and the Nijmegen PWA. Also a comparison of evaluated data with recent experimental data was made to check a quality of evaluation. Excellent agreement was found between the new experimental data and our PWA predictions.

  19. Measuring technical efficiency of output quality in intensive care units.

    PubMed

    Junoy, J P

    1997-01-01

    Presents some examples of the implications derived from imposing the objective of maximizing social welfare, subject to limited resources, on ethical care patients management in respect of quality performance of health services. Conventional knowledge of health economics points out that critically ill patients are responsible for increased use of technological resources and that they receive a high proportion of health care resources. Attempts to answer, from the point of view of microeconomics, the question: how do we measure comparative efficiency in the management of intensive care units? Analyses this question through data from an international empirical study using micro-economic measures of productive efficiency in public services (data envelopment analysis). Results show a 28.8 per cent level of technical inefficiency processing data from 25 intensive care units in the USA. PMID:10169231

  20. Photometer for measuring intensity and rhodopsin distributions in intact eyes

    NASA Astrophysics Data System (ADS)

    Williams, Theodore P.; Webbers, Jacob P. P.

    1995-09-01

    We describe a photometer that measures light transmitted through excised eyes. The instrument, an ocular transmission photometer, employs sensitive single photon-counting techniques, and its usefulness has been tested by the study of the absorbance of rhodopsin in retinal rod cells in situ. We find that absorbances of rat rods agree well with those predicted by microspectrophotometry without making corrections for cellular mosaics. Additional tests of the ocular transmission photometer show that (a) the instrument is sensitive to subtle differences in rhodopsin absorbance, known to exist in specific locations in the rat retina, and (b) using the rate of rhodopsin bleaching as the measure of intensity, we can determine the intensity distribution at several locations across the rat retina.

  1. Measurement of Kirchhoff's stress intensity factors in bending plates

    NASA Astrophysics Data System (ADS)

    Bäcker, D.; Kuna, M.; Häusler, C.

    2014-03-01

    A measurement method of the stress intensity factors defined by KIRCHHOFF's theory for a crack in a bending plate is shown. For this purpose, a thin piezoelectric polyvinylidene fluoride film (PVDF) is attached to the surface of the cracked plate. The measured electrical voltages are coupled with the load type and the crack tip position relative to the sensor film. Stress intensity factors and the crack tip position can be determined by solving the non-linear inverse problem based on the measured signals. To guarantee solvability of the problem, more measuring electrodes on the film have to be taken in to account. To the developed sensor concept the KIRCHHOFF's plate theory has been applied. In order to connect the electrical signals and the stress intensity factors the stresses near the crack tip have to be written in eigenfunctions (see WILLIAMS [1]). The presented method was verified by means of the example of a straight crack of the length 2a in an infinite isotropic plate under all- side bending. It was found that the positioning of the electrodes is delimited by two radii. On one hand, the measurement points should not be too close to the crack tip. In this area, the Kirchhoff's plate theory cannot be used effectively. On the other hand, the measuring electrodes should be placed at a smaller distance to each other and not too far from the crack tip regarding the convergence radius of the WILLIAMS series expansion. Test calculations on a straight crack in an infinite isotropic plate showed the general applicability of the measurement method.

  2. Measurement of the Absolute Branching Fractions of$B^\\pm \\to K^\\pm X_{c\\bar c}$

    SciTech Connect

    Aubert, B.; Barate, R.; Boutigny, D.; Couderc, F.; Karyotakis, Y.; Lees, J.P.; Poireau, V.; Tisserand, V.; Zghiche, A.; Grauges, E.; Palano, A.; Pappagallo, M.; Pompili, A.; Chen, J.C.; Qi, N.D.; Rong, G.; Wang, P.; Zhu, Y.S.; Eigen, G.; Ofte, I.; Stugu, B. /Bergen U. /LBL, Berkeley /UC, Berkeley /Birmingham U. /Ruhr U., Bochum /Bristol U. /British Columbia U. /Brunel U. /Novosibirsk, IYF /UC, Irvine /UCLA /UC, Riverside /UC, San Diego /UC, Santa Barbara /UC, Santa Cruz /Caltech /Cincinnati U. /Colorado U. /Colorado State U. /Dortmund U. /Dresden, Tech. U. /Ecole Polytechnique /Edinburgh U. /Ferrara U. /INFN, Ferrara /Frascati /Genoa U. /INFN, Genoa /Harvard U. /Heidelberg U. /Karlsruhe U., EKP /Imperial Coll., London /Iowa U. /Iowa State U. /Orsay, LAL /LLNL, Livermore /Liverpool U. /Queen Mary, U. of London /Royal Holloway, U. of London /Louisville U. /Manchester U. /Maryland U. /Massachusetts U., Amherst /MIT, LNS /McGill U. /Milan U. /INFN, Milan /Mississippi U. /Montreal U. /Mt. Holyoke Coll. /Naples U. /INFN, Naples /NIKHEF, Amsterdam /Notre Dame U. /Ohio State U. /Oregon U. /Padua U. /INFN, Padua /Paris U., VI-VII /Pennsylvania U. /Perugia U. /INFN, Perugia /Pisa U. /INFN, Pisa /Prairie View A-M /Princeton U. /Rome U. /INFN, Rome /Rostock U. /Rutherford /DAPNIA, Saclay /South Carolina U. /SLAC /Stanford U., Phys. Dept. /SUNY, Stony Brook /Tennessee U. /Texas U. /Texas U., Dallas /Turin U. /INFN, Turin /Trieste U. /INFN, Trieste /Valencia U., IFIC /Vanderbilt U. /Victoria U. /Warwick U. /Wisconsin U., Madison /Yale U. /Basilicata U., Potenza

    2005-11-02

    We study the two-body decays of B{sup {+-}} mesons to K{sup {+-}} and a charmonium state, X{sub c{bar c}}, in a sample of 210.5 fb{sup -1} of data from the BABAR experiment. We perform measurements of absolute branching fractions {Beta}(B{sup {+-}} {yields} K{sup {+-}} X{sub c{bar c}}) using a missing mass technique, and report several new or improved results. In particular, the upper limit {Beta}(B{sup {+-}} {yields} K{sup {+-}}(3872)) < 3.2 x 10{sup -4} at 90% CL and the inferred lower limit {Beta}(X(3872) {yields} J/{psi}{pi}{sup +}{pi}{sup -}) > 4.2% will help in understanding the nature of the recently discovered X(3872).

  3. Absolute dynamic viscosity measurements of subcooled liquid oxygen from 0.15 MPa to 1.0 MPa

    NASA Astrophysics Data System (ADS)

    Hilton, D. K.; Van Sciver, S. W.

    2008-01-01

    New absolute dynamic viscosity measurements of subcooled liquid oxygen are presented which were acquired in the pressure and temperature domains from 0.15 MPa to 1.0 MPa and from 55.20 K to 90.19 K, respectively. The measurements were acquired with an uncertainty of 1% at a 95% confidence level using a pressurized gravitational capillary (PGC) viscometer specifically designed for subcooled liquefied gases. The measurements are summarized by Arrhenius-Eyring plot parameters ( μ = Ae E/ RT), and interpreted with respect to the chemical reaction rate theory of viscosity by Eyring. The Arrhenius-Eyring plot parameters reproduce the dynamic viscosity measurements with only a 2% RMS error, which is remarkable considering just two parameters are involved, A, the factor which includes the weak pressure dependence of the dynamic viscosity, and E/ R, the barrier energy of the flow, where R is the universal gas constant. Although the Arrhenius-Eyring plot parameters do not have a discernible pressure dependence in the present work, the pressure coefficient versus temperature for the dynamic viscosity was determined from line plots of the dynamic viscosity versus pressure. The pressure coefficients suggest that the pressure dependence is very weak, yet positive, and increases with decreasing temperature. Measurements at pressures an order-of-magnitude higher are required to confirm this suggestion.

  4. Measurement of the absolute differential cross section of proton–proton elastic scattering at small angles

    DOE PAGES

    Mchedlishvili, D.; Chiladze, D.; Dymov, S.; Bagdasarian, Z.; Barsov, S.; Gebel, R.; Gou, B.; Hartmann, M.; Kacharava, A.; Keshelashvili, I.; et al

    2016-02-03

    The differential cross section for proton-proton elastic scattering has been measured at a beam kinetic energy of 1.0 GeV and in 200 MeV steps from 1.6 to 2.8 GeV for centre-of-mass angles in the range from 12°-16° to 25°-30°, depending on the energy. A precision in the overall normalisation of typically 3% was achieved by studying the energy losses of the circulating beam of the COSY storage ring as it passed repeatedly through the windowless hydrogen target of the ANKE magnetic spectrometer. It is shown that the data have a significant impact upon the results of a partial wave analysis.more » Furthermore, after extrapolating the differential cross sections to the forward direction, the results are broadly compatible with the predictions of forward dispersion relations.« less

  5. Procoagulant and platelet-derived microvesicle absolute counts determined by flow cytometry correlates with a measurement of their functional capacity

    PubMed Central

    Ayers, Lisa; Harrison, Paul; Kohler, Malcolm; Ferry, Berne

    2014-01-01

    Background Flow cytometry is the most commonly used technology to measure microvesicles (MVs). Despite reported limitations of this technique, MV levels obtained using conventional flow cytometry have yielded many clinically relevant findings, such as associations with disease severity and ability to predict clinical outcomes. This study aims to determine if MV enumeration by flow cytometry correlates with a measurement of their functional capacity, as this may explain how flow cytometry generates clinically relevant results. Methods One hundred samples from healthy individuals and patients with obstructive sleep apnoea were analysed by conventional flow cytometry (FACSCalibur) and by three functional MV assays: Zymuphen MP-activity in which data were given as phosphatidylserine equivalent, STA® Phospholipid Procoag Assay expressed as clotting time and Endogenous Thrombin Potential (ETP) reflecting in vitro thrombin generation. Correlations were determined by Spearman correlation. Results Absolute counts of lactadherin+ procoagulant MVs generated by flow cytometry weakly correlated with the results obtained from the Zymuphen MP-activity (r=0.5370, p<0.0001); correlated with ETP (r=0.7444, p<0.0001); negatively correlated with STA® Phospholipid Procoag Assay clotting time (−0.7872, p<0.0001), reflecting a positive correlation between clotting activity and flow cytometry. Levels of Annexin V+ procoagulant and platelet-derived MVs were also associated with functional assays. Absolute counts of MVs derived from other cell types were not correlated with the functional results. Conclusions Quantitative results of procoagulant and platelet-derived MVs from conventional flow cytometry are associated with the functional capability of the MVs, as defined by three functional MV assays. Flow cytometry is a valuable technique for the quantification of MVs from different cellular origins; however, a combination of several analytical techniques may give the most comprehensive

  6. Measuring absolute frequencies beyond the GPS limit via long-haul optical frequency dissemination.

    PubMed

    Clivati, Cecilia; Cappellini, Giacomo; Livi, Lorenzo F; Poggiali, Francesco; de Cumis, Mario Siciliani; Mancini, Marco; Pagano, Guido; Frittelli, Matteo; Mura, Alberto; Costanzo, Giovanni A; Levi, Filippo; Calonico, Davide; Fallani, Leonardo; Catani, Jacopo; Inguscio, Massimo

    2016-05-30

    Global Positioning System (GPS) dissemination of frequency standards is ubiquitous at present, providing the most widespread time and frequency reference for the majority of industrial and research applications worldwide. On the other hand, the ultimate limits of the GPS presently curb further advances in high-precision, scientific and industrial applications relying on this dissemination scheme. Here, we demonstrate that these limits can be reliably overcome even in laboratories without a local atomic clock by replacing the GPS with a 642-km-long optical fiber link to a remote primary caesium frequency standard. Through this configuration we stably address the 1S0-3P0 clock transition in an ultracold gas of 173Yb, with a precision that exceeds the possibilities of a GPS-based measurement, dismissing the need for a local clock infrastructure to perform beyond-GPS high-precision tasks. We also report an improvement of two orders of magnitude in the accuracy on the transition frequency reported in literature. PMID:27410109

  7. Measuring absolute frequencies beyond the GPS limit via long-haul optical frequency dissemination.

    PubMed

    Clivati, Cecilia; Cappellini, Giacomo; Livi, Lorenzo F; Poggiali, Francesco; de Cumis, Mario Siciliani; Mancini, Marco; Pagano, Guido; Frittelli, Matteo; Mura, Alberto; Costanzo, Giovanni A; Levi, Filippo; Calonico, Davide; Fallani, Leonardo; Catani, Jacopo; Inguscio, Massimo

    2016-05-30

    Global Positioning System (GPS) dissemination of frequency standards is ubiquitous at present, providing the most widespread time and frequency reference for the majority of industrial and research applications worldwide. On the other hand, the ultimate limits of the GPS presently curb further advances in high-precision, scientific and industrial applications relying on this dissemination scheme. Here, we demonstrate that these limits can be reliably overcome even in laboratories without a local atomic clock by replacing the GPS with a 642-km-long optical fiber link to a remote primary caesium frequency standard. Through this configuration we stably address the 1S0-3P0 clock transition in an ultracold gas of 173Yb, with a precision that exceeds the possibilities of a GPS-based measurement, dismissing the need for a local clock infrastructure to perform beyond-GPS high-precision tasks. We also report an improvement of two orders of magnitude in the accuracy on the transition frequency reported in literature.

  8. Intensive statistical complexity measure of pseudorandom number generators

    NASA Astrophysics Data System (ADS)

    Larrondo, H. A.; González, C. M.; Martín, M. T.; Plastino, A.; Rosso, O. A.

    2005-10-01

    A Statistical Complexity measure has been recently proposed to quantify the performance of chaotic Pseudorandom number generators (PRNG) (Physica A 354 (2005) 281). Here we revisit this quantifier and introduce two important improvements: (i) consideration of an intensive statistical complexity (Physica A 334 (2004) 119), and (ii) following the prescription of Brand and Pompe (Phys. Rev. Lett. 88 (2002) 174102-1) in evaluating the probability distribution associated with the PRNG. The ensuing new measure is applied to a very well-tested PRNG advanced by Marsaglia.

  9. The Reproducibility and Absolute Values of Echocardiographic Measurements of Left Ventricular Size and Function in Children are Algorithm Dependent

    PubMed Central

    Margossian, Renee; Chen, Shan; Sleeper, Lynn A.; Tani, Lloyd Y.; Shirali, Girish; Golding, Fraser; Tierney, Elif Seda Selamet; Altmann, Karen; Campbell, Michael J.; Szwast, Anita; Sharkey, Angela; Radojewski, Elizabeth; Colan, Steven D.

    2015-01-01

    Background Several quantification algorithms for measuring left ventricular (LV) size and function are used in clinical and research settings. We investigated the effect of the measurement algorithm and beat averaging on the reproducibility of measurements of the LV and assessed the magnitude of agreement among the algorithms in children with dilated cardiomyopathy (DCM). Methods Echocardiograms were obtained on 169 children from 8 clinical centers. Inter- and intra-reader reproducibility were assessed on measurements of LV volumes using biplane Simpson, modified Simpson (MS), and 5/6 x area x length (5/6AL) algorithms. Percent error (%error) was calculated as the inter- or intra-reader difference / mean x 100. Single beat measurements and the 3-beat average (3BA) were compared. Intra-class correlation coefficients (ICC) were calculated to assess agreement. Results Single beat inter-reader reproducibility was lowest (%error was highest) using biplane Simpson; 5/6AL and MS were similar but significantly better than biplane Simpson (p<.05). Single beat intra-reader reproducibility was highest using 5/6AL (p<.05). 3BA improved reproducibility for almost all measures (p<.05). Reproducibility in both single and 3BA values fell with greater LV dilation and systolic dysfunction (p<.05). ICCs were > 0.95 across measures, although absolute volume and mass values were systematically lower for biplane Simpson compared to MS and to 5/6AL. Conclusions The reproducibility of LV size and function measurements in children with DCM is highest using the 5/6AL algorithm, and can be further improved by using 3BA. However, values derived from different algorithms are not interchangeable. PMID:25728351

  10. Measurement of gamma-ray intensities of 231Th using semiconductor detectors

    NASA Astrophysics Data System (ADS)

    Chatani, Hiroshi

    1999-04-01

    Nuclide 231Th was yielded by the 232Th(n, 2n) reaction with neutron irradiation in the Kyoto University Reactor (KUR). Moreover, the thorium was purified chemically. Gamma-ray spectra of thorium have been measured using low-energy photon spectrometers and a high-purity germanium detector. Relative γ-ray intensities ranging from 25 to 352 keV in the decay of 231Th have been determined with satisfactory accuracy. The results are in very good agreement with those of earlier studies. We observe two new γ-rays at 77.69 and 177.66 keV, whose intensities are found to be (0.063±0.010)% and (0.00095±0.00020)%, respectively, relative to that of 84.21 keV taken as 100%. Absolute intensity of 84.21 keV γ-ray which is the most prominent one from the decay of 231Th and that of 185.739 keV following the decay of 235U are also determined from the secular equilibrium for 235U- 231Th. The results obtained in two cases are (6.60±0.25)% and (58±2)%, respectively.

  11. Leptin in whales: validation and measurement of mRNA expression by absolute quantitative real-time PCR.

    PubMed

    Ball, Hope C; Holmes, Robert K; Londraville, Richard L; Thewissen, Johannes G M; Duff, Robert Joel

    2013-01-01

    Leptin is the primary hormone in mammals that regulates adipose stores. Arctic adapted cetaceans maintain enormous adipose depots, suggesting possible modifications of leptin or receptor function. Determining expression of these genes is the first step to understanding the extreme physiology of these animals, and the uniqueness of these animals presents special challenges in estimating and comparing expression levels of mRNA transcripts. Here, we compare expression of two model genes, leptin and leptin-receptor gene-related product (OB-RGRP), using two quantitative real-time PCR (qPCR) methods: "relative" and "absolute". To assess the expression of leptin and OB-RGRP in cetacean tissues, we first examined how relative expression of those genes might differ when normalized to four common endogenous control genes. We performed relative expression qPCR assays measuring the amplification of these two model target genes relative to amplification of 18S ribosomal RNA (18S), ubiquitously expressed transcript (Uxt), ribosomal protein 9 (Rs9) and ribosomal protein 15 (Rs15) endogenous controls. Results demonstrated significant differences in the expression of both genes when different control genes were employed; emphasizing a limitation of relative qPCR assays, especially in studies where differences in physiology and/or a lack of knowledge regarding levels and patterns of expression of common control genes may possibly affect data interpretation. To validate the absolute quantitative qPCR methods, we evaluated the effects of plasmid structure, the purity of the plasmid standard preparation and the influence of type of qPCR "background" material on qPCR amplification efficiencies and copy number determination of both model genes, in multiple tissues from one male bowhead whale. Results indicate that linear plasmids are more reliable than circular plasmid standards, no significant differences in copy number estimation based upon background material used, and that the use of

  12. Status of the Trasco Intense Proton Source and emittance measurements

    NASA Astrophysics Data System (ADS)

    Celona, L.; Ciavola, G.; Gammino, S.; Chines, F.; Presti, M.; Andò, L.; Guo, X. H.; Gobin, R.; Ferdinand, R.

    2004-05-01

    The Trasco Intense Proton Source (TRIPS) was installed at INFN-LNS in May 2000 and has been fully operational since the Fall of 2000; now the source fulfills all the requirements of the TRASCO (Trasmutazione Scorie) project. The proton beam intensity easily exceeds 40 mA at the operating voltage of 80 kV. A set of emittance measurements was carried out for different source conditions and confirmed the simulations performed with the AXCEL code: in all the cases the rms normalized emittance is well lower than the value required for the injection into the RFQ (0.2 π mm mrad); the results will be shown and discussed. Finally a beam reliability of 99.8% has been found during a long run test lasting over 142 h.

  13. Measurement of zone plate efficiencies in the extreme ultraviolet and applications to radiation monitors for absolute spectral emission

    NASA Astrophysics Data System (ADS)

    Seely, John; Holland, Glenn; Bremer, James C.; Zukowski, Tim; Feser, Michael; Feng, Yan; Kjornrattanawanich, Benjawan; Goray, Leonid

    2006-08-01

    The diffraction efficiencies of a Fresnel zone plate (ZP), fabricated by Xradia Inc. using the electron-beam writing technique, were measured using polarized, monochromatic synchrotron radiation in the extreme ultraviolet wavelength range 3.4-22 nm. The ZP had 2 mm diameter, 3330 zones, 150 nm outer zone width, and a 1 mm central occulter. The ZP was supported by a 100 nm thick Si 3N 4 membrane. The diffraction patterns were recorded by CMOS imagers with phosphor coatings and with 5.2 μm or 48 μm pixels. The focused +n orders (n=1-4), the diverging -1 order, and the undiffracted 0 order were observed as functions of wavelength and off-axis tilt angle. Sub-pixel focusing of the +n orders was achieved. The measured efficiency in the +1 order was in the 5% to 30% range with the phase-shift enhanced efficiency occurring at 8.3 nm where the gold bars are partially transmitting. The +2 and higher order efficiencies were much lower than the +1 order efficiency. The efficiencies were constant when the zone plate was tilted by angles up to +/-1° from the incident radiation beam. This work indicates the feasibility and benefits of using zone plates to measure the absolute EUV spectral emissions from solar and laboratory sources: relatively high EUV efficiency in the focused +1 order, good out-of-band rejection resulting from the low higher-order efficiencies and the ZP focusing properties, insensitivity to (unfocused) visible light scattered by the ZP, flat response with off-axis angle, and insensitivity to the polarization of the radiation based on the ZP circular symmetry. EUV sensors with Fresnel zone plates potentially have many advantages over existing sensors intended to accurately measure absolute EUV emission levels, such as those implemented on the GOES N-P satellites that use transmission gratings which have off-axis sensitivity variations and poor out-of-band EUV and visible light rejection, and other solar and laboratory sensors using reflection gratings which

  14. Continuous, online measurement of the absolute plasma refill rate during hemodialysis using feedback regulated ultrafiltration: preliminary results.

    PubMed

    Brummelhuis, Walter J; van Schelven, Leonard J; Boer, Walther H

    2008-01-01

    Methods to continuously measure absolute refill during dialysis are not available. It would be useful to have such a method because it would allow investigating the mechanism of refill the effect of interventions. We designed a feedback algorithm that adjusts ultrafiltration rate (QUF) according to hemoglobin (Hb) concentration changes in such a way that relative blood volume (BV) remains constant within a narrow target range. In this situation, the generated QUF quantitatively reflects refill. Refill patterns were studied in five hypotension prone patients. In addition, on separate occasions, we studied the effect of antiembolism stockings (AES) and infusion of hydroxy-ethylated starch (HAES) on refill in these patients. Refill during the first hour fell significantly from 21 +/- 3 ml/min to 9 +/- 2 ml/min (p < 0.05). In the second hour, refill decreased further and became zero in four out of five patients. Neither AES nor HAES measurably affected refill. The marked and rapid fall in refill in the early stages of dialysis suggests untimely depletion of the interstitial compartment and underestimation of dry weight. We propose that continuous, online measurement of refill patterns may be of value for accurate estimation of dry weight in dialysis patients. PMID:18204322

  15. Improved measurement of the absolute branching fraction of D+→ bar{K}^0 μ +ν _{μ }

    NASA Astrophysics Data System (ADS)

    Ablikim, M.; Achasov, M. N.; Ai, X. C.; Albayrak, O.; Albrecht, M.; Ambrose, D. J.; Amoroso, A.; An, F. F.; An, Q.; Bai, J. Z.; Baldini Ferroli, R.; Ban, Y.; Bennett, D. W.; Bennett, J. V.; Bertani, M.; Bettoni, D.; Bian, J. M.; Bianchi, F.; Boger, E.; Boyko, I.; Briere, R. A.; Cai, H.; Cai, X.; Cakir, O.; Calcaterra, A.; Cao, G. F.; Cetin, S. A.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, H. Y.; Chen, J. C.; Chen, M. L.; Chen, S.; Chen, S. J.; Chen, X.; Chen, X. R.; Chen, Y. B.; Cheng, H. P.; Chu, X. K.; Cibinetto, G.; Dai, H. L.; Dai, J. P.; Dbeyssi, A.; Dedovich, D.; Deng, Z. Y.; Denig, A.; Denysenko, I.; Destefanis, M.; De Mori, F.; Ding, Y.; Dong, C.; Dong, J.; Dong, L. Y.; Dong, M. Y.; Dou, Z. L.; Du, S. X.; Duan, P. F.; Fan, J. Z.; Fang, J.; Fang, S. S.; Fang, X.; Fang, Y.; Farinelli, R.; Fava, L.; Fedorov, O.; Feldbauer, F.; Felici, G.; Feng, C. Q.; Fioravanti, E.; Fritsch, M.; Fu, C. D.; Gao, Q.; Gao, X. L.; Gao, X. Y.; Gao, Y.; Gao, Z.; Garzia, I.; Goetzen, K.; Gong, L.; Gong, W. X.; Gradl, W.; Greco, M.; Gu, M. H.; Gu, Y. T.; Guan, Y. H.; Guo, A. Q.; Guo, L. B.; Guo, R. P.; Guo, Y.; Guo, Y. P.; Haddadi, Z.; Hafner, A.; Han, S.; Hao, X. Q.; Harris, F. A.; He, K. L.; Held, T.; Heng, Y. K.; Hou, Z. L.; Hu, C.; Hu, H. M.; Hu, J. F.; Hu, T.; Hu, Y.; Huang, G. S.; Huang, J. S.; Huang, X. T.; Huang, X. Z.; Huang, Y.; Huang, Z. L.; Hussain, T.; Ji, Q.; Ji, Q. P.; Ji, X. B.; Ji, X. L.; Jiang, L. W.; Jiang, X. S.; Jiang, X. Y.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Johansson, T.; Julin, A.; Kalantar-Nayestanaki, N.; Kang, X. L.; Kang, X. S.; Kavatsyuk, M.; Ke, B. C.; Kiese, P.; Kliemt, R.; Kloss, B.; Kolcu, O. B.; Kopf, B.; Kornicer, M.; Kupsc, A.; Kühn, W.; Lange, J. S.; Lara, M.; Larin, P.; Leng, C.; Li, C.; Li, Cheng; Li, D. M.; Li, F.; Li, F. Y.; Li, G.; Li, H. B.; Li, H. J.; Li, J. C.; Li, Jin; Li, K.; Li, K.; Li, Lei; Li, P. R.; Li, Q. Y.; Li, T.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. N.; Li, X. Q.; Li, Y. B.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, G. R.; Lin, D. X.; Liu, B.; Liu, B. J.; Liu, C. X.; Liu, D.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H. B.; Liu, H. H.; Liu, H. H.; Liu, H. M.; Liu, J.; Liu, J. B.; Liu, J. P.; Liu, J. Y.; Liu, K.; Liu, K. Y.; Liu, L. D.; Liu, P. L.; Liu, Q.; Liu, S. B.; Liu, X.; Liu, Y. B.; Liu, Z. A.; Liu, Zhiqing; Loehner, H.; Lou, X. C.; Lu, H. J.; Lu, J. G.; Lu, Y.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, T.; Luo, X. L.; Lyu, X. R.; Ma, F. C.; Ma, H. L.; Ma, L. L.; Ma, M. M.; Ma, Q. M.; Ma, T.; Ma, X. N.; Ma, X. Y.; Ma, Y. M.; Maas, F. E.; Maggiora, M.; Mao, Y. J.; Mao, Z. P.; Marcello, S.; Messchendorp, J. G.; Min, J.; Min, T. J.; Mitchell, R. E.; Mo, X. H.; Mo, Y. J.; Morales Morales, C.; Muchnoi, N. Yu.; Muramatsu, H.; Nefedov, Y.; Nerling, F.; Nikolaev, I. B.; Ning, Z.; Nisar, S.; Niu, S. L.; Niu, X. Y.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Pan, Y.; Patteri, P.; Pelizaeus, M.; Peng, H. P.; Peters, K.; Pettersson, J.; Ping, J. L.; Ping, R. G.; Poling, R.; Prasad, V.; Qi, H. R.; Qi, M.; Qian, S.; Qiao, C. F.; Qin, L. Q.; Qin, N.; Qin, X. S.; Qin, Z. H.; Qiu, J. F.; Rashid, K. H.; Redmer, C. F.; Ripka, M.; Rong, G.; Rosner, Ch.; Ruan, X. D.; Sarantsev, A.; Savrié, M.; Schoenning, K.; Schumann, S.; Shan, W.; Shao, M.; Shen, C. P.; Shen, P. X.; Shen, X. Y.; Sheng, H. Y.; Shi, M.; Song, W. M.; Song, X. Y.; Sosio, S.; Spataro, S.; Sun, G. X.; Sun, J. F.; Sun, S. S.; Sun, X. H.; Sun, Y. J.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, X.; Tapan, I.; Thorndike, E. H.; Tiemens, M.; Ullrich, M.; Uman, I.; Varner, G. S.; Wang, B.; Wang, B. L.; Wang, D.; Wang, D. Y.; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, W.; Wang, W. P.; Wang, X. F.; Wang, Y.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. H.; Wang, Z. Y.; Wang, Z. Y.; Weber, T.; Wei, D. H.; Weidenkaff, P.; Wen, S. P.; Wiedner, U.; Wolke, M.; Wu, L. H.; Wu, L. J.; Wu, Z.; Xia, L.; Xia, L. G.; Xia, Y.; Xiao, D.; Xiao, H.; Xiao, Z. J.; Xie, Y. G.; Xiu, Q. L.; Xu, G. F.; Xu, J. J.; Xu, L.; Xu, Q. J.; Xu, Q. N.; Xu, X. P.; Yan, L.; Yan, W. B.; Yan, W. C.; Yan, Y. H.; Yang, H. J.; Yang, H. X.; Yang, L.; Yang, Y. X.; Ye, M.; Ye, M. H.; Yin, J. H.; Yu, B. X.; Yu, C. X.; Yu, J. S.; Yuan, C. Z.; Yuan, W. L.; Yuan, Y.; Yuncu, A.; Zafar, A. A.; Zallo, A.; Zeng, Y.; Zeng, Z.; Zhang, B. X.; Zhang, B. Y.; Zhang, C.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J.; Zhang, J. J.; Zhang, J. L.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, K.; Zhang, L.; Zhang, S. Q.; Zhang, X. Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. N.; Zhang, Y. T.; Zhang, Yu; Zhang, Z. H.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, J. W.; Zhao, J. Y.; Zhao, J. Z.; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, Q. W.; Zhao, S. J.; Zhao, T. C.; Zhao, Y. B.; Zhao, Z. G.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, W. J.; Zheng, Y. H.; Zhong, B.; Zhou, L.; Zhou, X.; Zhou, X. K.; Zhou, X. R.; Zhou, X. Y.; Zhu, K.; Zhu, K. J.; Zhu, S.; Zhu, S. H.; Zhu, X. L.; Zhu, Y. C.; Zhu, Y. S.; Zhu, Z. A.; Zhuang, J.; Zotti, L.; Zou, B. S.; Zou, J. H.

    2016-07-01

    By analyzing 2.93 fb^{-1} of data collected at √{s}=3.773 GeV with the BESIII detector, we measure the absolute branching fraction B(D+→ bar{K}^0μ +ν _{μ })=(8.72 ± 0.07_stat. ± 0.18_sys.)%, which is consistent with previous measurements within uncertainties but with significantly improved precision. Combining the Particle Data Group values of B(D^0→ K^-μ ^+ν _μ ), B(D+→ bar{K}^0 e+ν e), and the lifetimes of the D^0 and D^+ mesons with the value of B(D+→ bar{K}^0 μ +ν _{μ }) measured in this work, we determine the following ratios of partial widths: Γ (D^0→ K^-μ ^+ν _μ )/Γ (D+→ bar{K}^0μ +ν _{μ })=0.963± 0.044 and Γ (D+→ bar{K}^0 μ +ν _{μ })/Γ (D+→ bar{K}^0 e+ν e)=0.988± 0.033.

  16. Optical factors determined by the T-matrix method in turbidity measurement of absolute coagulation rate constants.

    PubMed

    Xu, Shenghua; Liu, Jie; Sun, Zhiwei

    2006-12-01

    Turbidity measurement for the absolute coagulation rate constants of suspensions has been extensively adopted because of its simplicity and easy implementation. A key factor in deriving the rate constant from experimental data is how to theoretically evaluate the so-called optical factor involved in calculating the extinction cross section of doublets formed during aggregation. In a previous paper, we have shown that compared with other theoretical approaches, the T-matrix method provides a robust solution to this problem and is effective in extending the applicability range of the turbidity methodology, as well as increasing measurement accuracy. This paper will provide a more comprehensive discussion of the physical insight for using the T-matrix method in turbidity measurement and associated technical details. In particular, the importance of ensuring the correct value for the refractive indices for colloidal particles and the surrounding medium used in the calculation is addressed, because the indices generally vary with the wavelength of the incident light. The comparison of calculated results with experiments shows that the T-matrix method can correctly calculate optical factors even for large particles, whereas other existing theories cannot. In addition, the data of the optical factor calculated by the T-matrix method for a range of particle radii and incident light wavelengths are listed.

  17. Measurement of natural background radiation intensity on a train.

    PubMed

    Chen, Yen-Fu; Lin, Jeng-Wei; Sheu, Rong-Jiun; Lin, Uei-Tyng; Jiang, Shiang-Huei

    2011-03-01

    This work aims to measure different components of natural background radiation on a train. A radiation measurement system consisting of four types of radiation detectors, namely, a Berkeley Lab cosmic-ray detector, moderated (3)He detector, high-pressure ionisation chamber and NaI(Tl) spectrometer, associated with a global positioning system unit was established for this purpose. For the commissioning of the system, a test measurement on a train along the railway around the northern Taiwan coast from Hsinchu to Hualien with a distance of ∼ 275 km was carried out. No significant variation of the intensities of the different components of natural background radiation was observed, except when the train went underground or in the tunnels. The average external dose rate received by the crew of the train was estimated to be 62 nSv h(-1).

  18. Absolute measurements of the electronic transition moments of seven band systems of the C2 molecule. Ph.D. Thesis - York Univ., Toronto

    NASA Technical Reports Server (NTRS)

    Cooper, D. M.

    1979-01-01

    Electronic transition moments of seven C2 singlet and triplet band systems in the 0.2-1.2 micron spectral region were measured. The measurements were made in emission behind incident shock waves in C2H2-argon mixtures. Narrow bandpass radiometers were used to obtain absolute measurements of shock-excited C2 radiation from which absolute electronic transition moments are derived by a synthetic spectrum analysis. New results are reported for the Ballik-Ramsay, Phillips, Swan, Deslandres-d'Azambuja, Fox-Herzberg, Mulliken, and Freymark systems.

  19. Absolute Summ

    NASA Astrophysics Data System (ADS)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  20. Absolute velocity measurements in the solar transition region and corona from observations of ultraviolet emission line profiles

    NASA Astrophysics Data System (ADS)

    Hassler, Donald M.

    An experimental technique to measure absolute velocities of minor ions formed in the solar transition region and corona is presented. A sounding rocket experiment July 27, 1987 obtained high resolution extreme ultraviolet (EUV) spectra along a solar diameter with spatial resolution of 20 x 20 arcseconds. The center-to-limb behavior of four representative lines (Si II 1553, Fe II 1563, CIV 1548, Ne VIII 770) formed at different heights in the solar atmosphere is discussed. Assuming that horizontal motions cancel statistically so that the line-of-sight velocity approaches zero at the limb, we find a net radial downflow of approximately 7.5 +/- 1.0 km/s for C IV, 2.7 +/- 1.5 km/s for Fe II 1563, and upper limits of 0 +/- 1.2 km/s and 0 +/- 4 km/s for Si II and Ne VIII, respectively. The absolute wavelengths of each emission line were determined by direct comparison with wavelengths of known platinum lines generated by an inflight calibration lamp. We then test the assumption of line-of-sight velocity approaching zero at the limb by comparing our wavelengths with recently published laboratory rest wavelengths of the solar emission lines. We find agreement within the published uncertainties of the laboratory wavelengths. The result for Si II indicates that the next radial flow in the chromosphere is near zero, although small scale velocity structures may vary by as much as 4-6 km/sec. The center-to-limb behavior of Fe II 1563 suggests, contrary to previous thinking, that there might be a significant contribution of Fe II emission at higher temperatures characteristic of the lower transition region. Finally, the upper limit on the radial flow velocity for Ne VIII provides a constraint on the radial flow at coronal temperatures. Complicating the accurate measurement of Doppler velocities is the presence of small nonlinearities in the microchannel plates used in UV and EUV detectors which introduce small position offsets between the input and output of the detector. The

  1. Absolute measurement of cerebral optical coefficients, hemoglobin concentration and oxygen saturation in old and young adults with near-infrared spectroscopy

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We present near-infrared spectroscopy measurement of absolute cerebral hemoglobin concentration and saturation in a large sample of 36 healthy elderly (mean age, 85 ± 6 years) and 19 young adults (mean age, 28 ± 4 years). Non-invasive measurements were obtained on the forehead using a commercially a...

  2. A Novel Microsensor for Measuring Angular Distribution of Radiative Intensity.

    PubMed

    Murphy, Thomas E; Pilorz, Stuart; Prufert-Bebout, Leslie; Bebout, Brad

    2015-01-01

    This article presents the design, construction and characterization of a novel type of light probe for measuring the angular radiance distribution of light fields. The differential acceptance angle (DAA) probe can resolve the directionality of a light field in environments with steep light gradients, such as microbial mats, without the need to remove, reorient, and reinsert the probe, a clear advantage over prior techniques. The probe consists of an inner irradiance sensor inside a concentric, moveable light-absorbing sheath. The radiative intensity in a specific zenith direction can be calculated by comparing the irradiance onto the sensor at different acceptance angles. We used this probe to measure the angular radiance distribution of two sample light fields, and observed good agreement with a conventional radiance probe. The DAA probe will aid researchers in understanding light transfer physics in dense microbial communities and expedite validation of numerical radiative transfer models for these environments. PMID:25763775

  3. Improved entrance optics design for ground-based solar spectral ultraviolet irradiance measurements and system absolute calibration

    NASA Astrophysics Data System (ADS)

    Dai, Caihong; Yu, Jialin; Huang, Bo; Tian, Yan

    2009-07-01

    The angular response of entrance optics is an important parameter for solar spectral UV measurements, and ideal cosine entrance optics is required to measure ground-based global solar spectral UV irradiance including direct and diffuse radiation over a solid angle of 2π sr. Early international comparisons have shown that deviations from the ideal cosine response lead to uncertainties in solar measurements of more than 10%. A special spectroradiometer used for solar spectral UV measurements was developed at National Institute of Metrology (NIM). Based on Polytetrafluoroethylene (PTFE) integrating sphere, seven kinds of cosine-entrance system were designed and compared. A special cosine measurement apparatus was developed to measure the angular response of the entrance optics. Experimental results show that, the integral cosine error is 1.41% for a novel combination entrance optics, which is composed by a PTFE integrating sphere, a spherical ground quartz diffuser and a special correction ring, and the cosine error is 0.08% for an incidence angle of θ=+/-30°, 0.84% at θ=+/-45°, -0.47% at θ=+/-60°, -0.74% at θ=+/-70°, and 5.47% at θ=+/-80°. With the new non-plane entrance optics, the angular response of the solar UV spectroradiometer is improved evidently, but on the other side, the system's absolute calibration becomes more difficult owing to the curved geometry of the new diffuser. The calibration source is a 1000W tungsten halogen lamp, but the measurement object is the global radiation of the solar, so a small error of the calibration distance will lead to an enormous measurement error of solar spectral UV irradiance. When the calibration distance is 500mm, for an actual diffuser with spherical radius 32.5mm and spherical height 20mm, the calibration error will be up to 3%~10% on the assumption that the starting point was calculated just from the acme or the bottom of the half-spherical diffuser. It was investigated that which point inside the

  4. Mask CD measurement approach by diffraction intensity for lithography equivalent

    NASA Astrophysics Data System (ADS)

    Nagai, Takaharu; Mesuda, Kei; Sutou, Takanori; Inazuki, Yuichi; Hashimoto, Hiroyuki; Yokoyama, Toshifumi; Toyama, Nobuhito; Morikawa, Yasutaka; Mohri, Hiroshi; Hayashi, Naoya

    2008-04-01

    In 45nm node and beyond with hyper NA lithography, mask topography effect is not ignorable and mask CD bias impacts printing performance such as MEEF or exposure latitude. In that situation, 3D simulation is required for precise evaluation of printing performance and the accuracy of 3D mask model on simulation is a key issue. Verification of 3D mask model by diffraction intensity measurement with AIMS TM45-193i was discussed in our previous works. Through the verification, though real mask successfully creates effective or simulated diffractions, CD on 3D mask model on simulation was different to that on AIMS TM result which was measured by CD-SEM. Therefore, purpose of this work is to analyze the cause of CD differences through AIMS TM diffraction intensity evaluation in various conditions (mask material, pattern pitch, mask CD bias and mask CD-SEM system). Furthermore, lithography equivalent CD is proposed as width of "ideal" mask shape. As a result achieved from the experiments, constant CD shift was successfully observed at hp40-70nm L/S pattern with varied bias for both 6% EAPSM and Binary masks. It can be said that mask topography difference related to mask material and pattern dimensions has not been observed. On the other hand, the value of CD shift was smaller on the condition of newer generation CD-SEM measurement. Other result achieved from further discussion and analysis, cause of the CD difference was explained using simple SEM image simulation. The CD difference was mainly changed by electron beam size factor, and it was stable with side wall angle in the range of 80 to 90 degree if the middle CD, which is the width of 3D model defined at the half height of the mask film's thickness, is constant. Since side wall angles on actual masks are nearly 90 degree, lithography equivalent CD could be measured by CD-SEM with constant offset.

  5. Automated fat measurement and segmentation with intensity inhomogeneity correction

    NASA Astrophysics Data System (ADS)

    Sussman, Daniel L.; Yao, Jianhua; Summers, Ronald M.

    2010-03-01

    Adipose tissue (AT) content, especially visceral AT (VAT), is an important indicator for risks of many disorders, including heart disease and diabetes. Fat measurement by traditional means is often inaccurate and cannot separate subcutaneous and visceral fat. MRI offers a medium to obtain accurate measurements and segmentation between subcutaneous and visceral fat. We present an approach to automatically label the voxels associated with adipose tissue and segment them between subcutaneous and visceral. Our method uses non-parametric non-uniform intensity normalization (N3) to correct for image artifacts and inhomogeneities, fuzzy c-means to cluster AT regions and active contour models to separate SAT and VAT. Our algorithm has four stages: body masking, preprocessing, SAT and VAT separation, and tissue classification and quantification. The method was validated against a manual method performed by two observers, which used thresholds and manual contours to separate SAT and VAT. We measured 25 patients, 22 of which were included in the final analysis and the other three had too much artifact for automated processing. For SAT and total AT, differences between manual and automatic measurements were comparable to manual inter-observer differences. VAT measurements showed more variance in the automated method, likely due to inaccurate contours.

  6. On the uncertainties in the measurement of absolute (true) TEC over Indian equatorial and low latitude sectors

    NASA Astrophysics Data System (ADS)

    Rama Rao, P. V. S.; Venkatesh, K.; Prasad, D. S. V. V. D.; Niranjan, K.

    2013-04-01

    The Indian sector encompasses the equatorial and low latitude regions where the ionosphere is highly dynamic and is characterized by the equatorial ionization anomaly (EIA) resulting in large latitudinal electron density gradients causing errors and uncertainties in the estimation of range delays in satellite based navigation systems. The diurnal and seasonal variations of standard deviations in the TEC data measured during the low sunspot period 2004-2005 at 10 different Indian stations located from equator to the anomaly crest region and beyond are examined and presented. The day-to-day variability in TEC is found to be lowest at the equatorial station and increases with latitude up to the crest region of EIA and decreases beyond.Further, the measured values of TEC using grid based system are also examined with a view to ascertain the uncertainties in the measurement of the absolute value of TEC. The VTEC values derived from different satellite ray paths visible in the 5° × 5° grid over any particular location at any given point of time have shown significant differences in the TEC derived from one ray path to the other ranging from a minimum of 10% to a maximum of about 50% leading to the possibility of introducing errors in the interpolation technique. Also, the TEC values derived simultaneously along two different satellite ray paths simultaneously passing through the same sub-ionospheric point at the same point of time are found to be significantly different from each other although they are expected to be same. These uncertainties are found to be more pronounced at and around the EIA anomaly crest region with larger variations particularly around noon-time hours.

  7. On the variabilities and uncertainties in the measurement of absolute (true) TEC over Indian equatorial and low latitude sectors

    NASA Astrophysics Data System (ADS)

    Rao Pvs, Rama; Kavutarapu, Venkatesh; Prasad, Dsvvd; Kandula, Niranjan

    The Indian sector encompasses the equatorial and low latitude regions where the ionosphere is highly dynamic and is characterized by the Equatorial Ionization Anomaly (EIA) resulting in large latitudinal electron density gradients causing ambiguities in the estimation of range delays in satellite based augmentation and navigation systems. The diurnal and latitudinal variations in the day-to-day variability of the Total Electron Content (TEC) in the Indian sector during the low sunspot period 2004-2005 are studied and presented. The diurnal and seasonal variations of standard deviations in the TEC measured at ten different Indian stations located from equator to the anomaly crest region and beyond are presented. The day-to-day variability in TEC is found to be lowest at the equatorial station, Trivandrum and increases with latitude up to the crest region of EIA and decreases beyond. Further, the measurements of TEC using grid based studies are also carried out with a view to ascertain the uncertainties in the measurement of the absolute value of TEC. The TEC derived from different satellite ray paths visible in the 50 x 50 grid over any particular location at any particular given point of time have shown significant differences in the TEC derived from one ray path to the other leading to the possibility of introducing errors in the interpolation technique. Also, the TEC values derived simultaneously along two different satellite ray paths simultaneously passing through the same sub-ionospheric point at the same point of time are found to be quite different from each other. These uncertainties are found to be more pronounced at and around the EIA anomaly crest region with larger variations particularly around noon-time hours.

  8. Absolute fracture risk assessment using lumbar spine and femoral neck bone density measurements: derivation and validation of a hybrid system.

    PubMed

    Leslie, William D; Lix, Lisa M

    2011-03-01

    The World Health Organization (WHO) Fracture Risk Assessment Tool (FRAX) computes 10-year probability of major osteoporotic fracture from multiple risk factors, including femoral neck (FN) T-scores. Lumbar spine (LS) measurements are not currently part of the FRAX formulation but are used widely in clinical practice, and this creates confusion when there is spine-hip discordance. Our objective was to develop a hybrid 10-year absolute fracture risk assessment system in which nonvertebral (NV) fracture risk was assessed from the FN and clinical vertebral (V) fracture risk was assessed from the LS. We identified 37,032 women age 45 years and older undergoing baseline FN and LS dual-energy X-ray absorptiometry (DXA; 1990-2005) from a population database that contains all clinical DXA results for the Province of Manitoba, Canada. Results were linked to longitudinal health service records for physician billings and hospitalizations to identify nontrauma vertebral and nonvertebral fracture codes after bone mineral density (BMD) testing. The population was randomly divided into equal-sized derivation and validation cohorts. Using the derivation cohort, three fracture risk prediction systems were created from Cox proportional hazards models (adjusted for age and multiple FRAX risk factors): FN to predict combined all fractures, FN to predict nonvertebral fractures, and LS to predict vertebral (without nonvertebral) fractures. The hybrid system was the sum of nonvertebral risk from the FN model and vertebral risk from the LS model. The FN and hybrid systems were both strongly predictive of overall fracture risk (p < .001). In the validation cohort, ROC analysis showed marginally better performance of the hybrid system versus the FN system for overall fracture prediction (p = .24) and significantly better performance for vertebral fracture prediction (p < .001). In a discordance subgroup with FN and LS T-score differences greater than 1 SD, there was a significant

  9. Measurement of CMRO2 in neonates undergoing intensive care using near infrared spectroscopy.

    PubMed

    Elwell, Clare E; Henty, Julian R; Leung, Terence S; Austin, Topun; Meek, Judith H; Delpy, David T; Wyatt, John S

    2005-01-01

    Greater understanding of the rate of oxygen delivery and uptake in sick preterm and term infants undergoing intensive care is an important aim of brain-orientated neonatal medicine. Near infrared spectroscopy (NIRS) is a continuous, non-invasive and portable technique which can be used to measure cerebral blood flow (CBF) in infants. It is also possible to use spatially resolved spectroscopy to measure absolute mean cerebral oxygen saturation (SmcO2). The aim of this study was to investigate the derivation of cerebral metabolic rate for oxygen (CMRO2) from these two measurements. Nine preterm infants were studied, of median (range) gestational age 25 (23-37) weeks. A NIRO300 was used to measure CBF and SmcO2 simultaneously over the right and left hemisphere. Median (range) left and right cerebral hemisphere values for CMRO2 were 0.95 (0.79-1.53) ml 100g(-1) x min(-1) and 0.88 (0.69-1.46) ml 100g(-1) x min(-1), respectively. No significant difference was seen between the left- and right-sided values. These values are similar to median (range) values previously reported in infants using positron emission tomography or more invasive NIRS methods. Further work is necessary to define limits on the use of this technique, particularly in the assumption of the venous:arterial compartment volume ratio across different infants. PMID:16594161

  10. Aerosol classification using EARLINET measurements for an intensive observational period

    NASA Astrophysics Data System (ADS)

    Papagiannopoulos, Nikolaos; Mona, Lucia; Pappalardo, Gelsomina

    2016-04-01

    ACTRIS (Aerosols, Clouds and Trace gases Research Infrastructure Network) organized an intensive observation period during summer 2012. This campaign aimed at the provision of advanced observations of physical and chemical aerosol properties, at the delivery of information about the 3D distribution of European atmospheric aerosols, and at the monitoring of Saharan dust intrusions events. EARLINET (European Aerosol Research Lidar Network) participated in the ACTRIS campaign through the addition of measurements according to the EARLINET schedule as well as daily lidar-profiling measurements around sunset by 11 selected lidar stations for the period from 8 June - 17 July. EARLINET observations during this almost two-month period are used to characterize the optical properties and vertical distribution of long-range transported aerosol over the broader area of Mediterranean basin. The lidar measurements of aerosol intensive parameters (lidar ratio, depolarization, Angstrom exponents) are shown to vary with location and aerosol type. A methodology based on EARLINET observations of frequently observed aerosol types is used to classify aerosols into seven separate types. The summertime Mediterranean basin is prone to African dust aerosols. Two major dust events were studied. The first episode occurred from the 18 to 21 of the June and the second one lasted from 28 June to 6 July. The lidar ratio within the dust layer was found to be wavelength independent with mean values of 58±14 sr at 355 nm and 57±11 sr at 532 nm. For the particle linear depolarization ratio, mean values of 0.27±0.04 at 532 nm have been found. Acknowledgements. The financial support for EARLINET in the ACTRIS Research Infrastructure Project by the European Union's Horizon 2020 research and innovation programme under grant agreement no. 654169 and previously under grant agreement no. 262254 in the Seventh Framework Programme (FP7/2007-2013) is gratefully acknowledged.

  11. Real-time wavefront reconstruction from intensity measurements

    NASA Astrophysics Data System (ADS)

    Smith, Carlas; Marinica, Raluca; Verhaegen, Michel

    2013-12-01

    We propose an ecient approximation to the nonlinear phase diversity method for wavefront reconstruction method from intensity measurements in order to avoid the shortcomings of the nonlinear phase diversity method that prevent its real-time application, such as its computationally complex and the presence of local minima. The new method is called linear sequential phase diversity (LSPD). The method assumes that residual phase aberration is small and makes use of a rst order Taylor expansion of the point spread function (PSF). The Taylor expansion is performed in two dierent phase diversities, that can be arbitrary (large) pupil shapes in order to optimize the phase retrieval. For static aberrations LSPD makes use of two images that are collected at each iteration step of the algorithm. In each step the residual phase aberrations are estimated by solving a linear least squares problem, followed by the use of a deformable mirror to correct for the aberrations. The computational complexity of LSPD is O(m*m) - where m*m is the number of pixels. For the static case the convergence of the LSPD iterations have been studied and experimentally veried. In an extensive comparison the method is compared with the recently proposed method of [1]. This study demonstrates the improved performance both computationally and in accuracy with respect to existing competitors that also linearize the PSF. A further contribution of the paper is that we extend the static LSPD method to the case of dynamic wavefront reconstruction based on intensity measurements. Here the dynamics are assumed to be modelled standardly by a linear innovation model such that its spectrum e.g. approximates that given by Kolmogorov. The advantage of the application of the dynamic variant of the LSPD method is that in closed-loop the assumption that the residual phase aberration is small is justiable, since the goal of the controller is to reduce (minimize) the residual phase aberration. This unique contribution

  12. Measurement of absolute E2 transition strengths in {sup 176}W: Signatures for a rapid shape change

    SciTech Connect

    Fransen, Ch.; Dewald, A.; Friessner, G.; Hackstein, M.; Jolie, J.; Pissulla, T.; Rother, W.; Zell, K.-O.; Moeller, O.

    2011-10-28

    The X(5) symmetry describes nuclei at the critical point of the shape phase transition from axially deformed rotor nuclei to spherical vibrators. {sup 150}Nd, {sup 152}Sm, and {sup 154}Gd were the first nuclei where the predicted characteristics of the X(5) symmetry were observed. Later it was shown that also {sup 176,178,180}Os can be successfully described with the X(5) symmetry.In the close vicinity of shape phase transitions one expects strongly changing nuclear shapes. In the X(5) region around A = 150 this was observed for nuclei with different neutron numbers, whereas in the X(5) region around A = 180 this is to be expected for different proton numbers. The aim of the work presented here is the confirmation of a rapid shape change for nuclei close to {sup 178}Os. Besides the knowledge on the level scheme of the nuclei of interest, especially absolute E2 transition strengths are crucial for the interpretation of nuclear structure. Prolate deformation is expected for {sup 176}W. Thus we performed a recoil distance Doppler shift (RDDS) measurement on {sup 176}W to measure E2 transition strengths from level lifetimes. The experiment was performed at the Cologne FN TANDEM accelerator with the Cologne coincidence plunger with the reaction {sup 169}Dy({sup 16}O,4n){sup 176}W and a beam energy of 80 MeV. We will present our experimental results and relate them to data on the neighboring nuclei {sup 178}Os and {sup 182}Pt. The results will be discussed in the framework of nuclear shape transitions in this mass region and compared to calculations with both the Interacting Boson Model (IBM) and the GCM.

  13. Present-day Surface Deformation and Vertical Motion In The Central Alborz (iran) From GPS and Absolute Gravity Measurements.

    NASA Astrophysics Data System (ADS)

    Masson, F.; Sedighi, M.; Hinderer, J.; Bayer, R.; Nilforoushan, F.; Luck, J.-M.; Vernant, P.; Chéry, J.

    The present tectonic of Iran results from the north-south convergence between Eura- sia and Arabia, with a rate of about 3 cm/year. The deformation of Iran is concen- trated in major belts along the south-western border (Zagros), the southern shore of the Caspian Sea (Alborz) and along the north-east border (Kopet-Dag). The Alborz range is an east-west mountain range which accommodates about 1 cm/year of short- ening between the Central Iranian Desert and the south Caspian Sea. The main tec- tonic structures are generally overthrusting range-parallel faults northward dipping in the south (North Tehran fault, Mosha fault) and southward dipping in the north (Amir fault, North Border fault). The compressive tectonic in the Alborz range is certainly accommodated by large vertical motions along the major faults. To study the defor- mation (horizontal and vertical movement) we have installed and measured a GPS network of 14 sites crossing the Alborz range east of Tehran. The GPS network is measured during campaigns performed each year. In order to well constrained the ver- tical deformation of the southern border of the Alborz, we have performed colocated GPS and absolute gravity measurements in 3 sites, one near the Mosha fault (Abali), one in the frontal thrust area of Tehran and one in the stable central Iranian block (Chesmeh-Sour). After two measures (2000 and 2001), some interesting preliminary results will be shown. The observed gravity variation for one year (Sept. 2000 - Sept. 2001) is -3.0 mgal +-2.6 mgal (Abali), -24.2 mgal +-4.8 mgal (Tehran) and +4.7 mgal +-2.3 mgal (Chesmeh-Sour). These results could be explained respectively by a tec- tonic uplift of about 10 mm/year in the Alborz, water pumping in the Tehran area and (unexplained) subsidence at Chesmeh-Sour. These results will be compared to the first estimation of the deformation obtained by GPS (horizontal repeatability < 3 mm and vertical repeatability < 5 mm).

  14. Leptin in Whales: Validation and Measurement of mRNA Expression by Absolute Quantitative Real-Time PCR

    PubMed Central

    Ball, Hope C.; Holmes, Robert K.; Londraville, Richard L.; Thewissen, Johannes G. M.; Duff, Robert Joel

    2013-01-01

    Leptin is the primary hormone in mammals that regulates adipose stores. Arctic adapted cetaceans maintain enormous adipose depots, suggesting possible modifications of leptin or receptor function. Determining expression of these genes is the first step to understanding the extreme physiology of these animals, and the uniqueness of these animals presents special challenges in estimating and comparing expression levels of mRNA transcripts. Here, we compare expression of two model genes, leptin and leptin-receptor gene-related product (OB-RGRP), using two quantitative real-time PCR (qPCR) methods: “relative” and “absolute”. To assess the expression of leptin and OB-RGRP in cetacean tissues, we first examined how relative expression of those genes might differ when normalized to four common endogenous control genes. We performed relative expression qPCR assays measuring the amplification of these two model target genes relative to amplification of 18S ribosomal RNA (18S), ubiquitously expressed transcript (Uxt), ribosomal protein 9 (Rs9) and ribosomal protein 15 (Rs15) endogenous controls. Results demonstrated significant differences in the expression of both genes when different control genes were employed; emphasizing a limitation of relative qPCR assays, especially in studies where differences in physiology and/or a lack of knowledge regarding levels and patterns of expression of common control genes may possibly affect data interpretation. To validate the absolute quantitative qPCR methods, we evaluated the effects of plasmid structure, the purity of the plasmid standard preparation and the influence of type of qPCR “background” material on qPCR amplification efficiencies and copy number determination of both model genes, in multiple tissues from one male bowhead whale. Results indicate that linear plasmids are more reliable than circular plasmid standards, no significant differences in copy number estimation based upon background material used, and

  15. Measurement of the Absolute Magnitude and Time Courses of Mitochondrial Membrane Potential in Primary and Clonal Pancreatic Beta-Cells.

    PubMed

    Gerencser, Akos A; Mookerjee, Shona A; Jastroch, Martin; Brand, Martin D

    2016-01-01

    The aim of this study was to simplify, improve and validate quantitative measurement of the mitochondrial membrane potential (ΔψM) in pancreatic β-cells. This built on our previously introduced calculation of the absolute magnitude of ΔψM in intact cells, using time-lapse imaging of the non-quench mode fluorescence of tetramethylrhodamine methyl ester and a bis-oxonol plasma membrane potential (ΔψP) indicator. ΔψM is a central mediator of glucose-stimulated insulin secretion in pancreatic β-cells. ΔψM is at the crossroads of cellular energy production and demand, therefore precise assay of its magnitude is a valuable tool to study how these processes interplay in insulin secretion. Dispersed islet cell cultures allowed cell type-specific, single-cell observations of cell-to-cell heterogeneity of ΔψM and ΔψP. Glucose addition caused hyperpolarization of ΔψM and depolarization of ΔψP. The hyperpolarization was a monophasic step increase, even in cells where the ΔψP depolarization was biphasic. The biphasic response of ΔψP was associated with a larger hyperpolarization of ΔψM than the monophasic response. Analysis of the relationships between ΔψP and ΔψM revealed that primary dispersed β-cells responded to glucose heterogeneously, driven by variable activation of energy metabolism. Sensitivity analysis of the calibration was consistent with β-cells having substantial cell-to-cell variations in amounts of mitochondria, and this was predicted not to impair the accuracy of determinations of relative changes in ΔψM and ΔψP. Finally, we demonstrate a significant problem with using an alternative ΔψM probe, rhodamine 123. In glucose-stimulated and oligomycin-inhibited β-cells the principles of the rhodamine 123 assay were breached, resulting in misleading conclusions.

  16. Contextual phase estimation from two-plane intensity measurements.

    PubMed

    Deepak, V Joshua; Ivan, J Solomon

    2016-06-01

    In this work we construct examples of paraxial light fields whose intensities defined at all points in space do not have a corresponding cross-spectrally pure field amplitude reproducing the same set of transported intensities at all transverse planes. Nevertheless, two spatially separated transverse plane intensities as drawn from these examples are shown to have a corresponding cross-spectrally pure field amplitude, which, through paraxial free propagation between these two planes, reproduces the drawn transverse plane intensities. And the phase associated with such a field amplitude at a given transverse plane is found to be contextual, and intrinsically dependent on the pairing plane. PMID:27409450

  17. Probabilistic seismic demand analysis using advanced ground motion intensity measures

    USGS Publications Warehouse

    Tothong, P.; Luco, N.

    2007-01-01

    One of the objectives in performance-based earthquake engineering is to quantify the seismic reliability of a structure at a site. For that purpose, probabilistic seismic demand analysis (PSDA) is used as a tool to estimate the mean annual frequency of exceeding a specified value of a structural demand parameter (e.g. interstorey drift). This paper compares and contrasts the use, in PSDA, of certain advanced scalar versus vector and conventional scalar ground motion intensity measures (IMs). One of the benefits of using a well-chosen IM is that more accurate evaluations of seismic performance are achieved without the need to perform detailed ground motion record selection for the nonlinear dynamic structural analyses involved in PSDA (e.g. record selection with respect to seismic parameters such as earthquake magnitude, source-to-site distance, and ground motion epsilon). For structural demands that are dominated by a first mode of vibration, using inelastic spectral displacement (Sdi) can be advantageous relative to the conventionally used elastic spectral acceleration (Sa) and the vector IM consisting of Sa and epsilon (??). This paper demonstrates that this is true for ordinary and for near-source pulse-like earthquake records. The latter ground motions cannot be adequately characterized by either Sa alone or the vector of Sa and ??. For structural demands with significant higher-mode contributions (under either of the two types of ground motions), even Sdi (alone) is not sufficient, so an advanced scalar IM that additionally incorporates higher modes is used.

  18. Recognizing, naming, and measuring a family intensive care unit syndrome.

    PubMed

    Netzer, Giora; Sullivan, Donald R

    2014-03-01

    Most major decisions in the intensive care unit (ICU) regarding goals of care are shared by clinicians and someone other than the patient. Multicenter clinical trials focusing on improved communication between clinicians and these surrogate decision makers have not reported consistently improved outcomes. We suggest that acquired maladaptive reasoning may contribute importantly to failure of the intervention strategies tested to date. Surrogate decision makers often suffer significant psychological morbidity in the form of stress, anxiety, depression, and post-traumatic stress disorder. Family members in the ICU also suffer cognitive blunting and sleep deprivation. Their decision-making abilities are eroded by anticipatory grief and cognitive biases, while personal and family conflicts further impact their decision making. We propose recognizing a family ICU syndrome to describe the morbidity and associated decision-making impairment experienced by many family members of patients with acute critical illness (in the ICU) and chronic critical illness (in the long-term, acute care hospital). Research rigorously using models of compromised decision making may help elucidate both mechanisms of impairment and targets for intervention. Better quantifying compromised decision making and its relationship to poor outcomes will allow us to formulate and advance useful techniques. The use of decision aids and improving ICU design may provide benefit now and in the near future. In measuring interventions targeting cognitive barriers, clinically significant outcomes, such as time to decision, should be considered. Statistical approaches, such as survival models and rank statistic testing, will increase our power to detect differences in our interventions.

  19. Optimal ground motion intensity measure for long-period structures

    NASA Astrophysics Data System (ADS)

    Guan, Minsheng; Du, Hongbiao; Cui, Jie; Zeng, Qingli; Jiang, Haibo

    2015-10-01

    This paper aims to select the most appropriate ground motion intensity measure (IM) that is used in selecting earthquake records for the dynamic time history analysis of long-period structures. For this purpose, six reinforced concrete frame-core wall structures, designed according to modern seismic codes, are studied through dynamic time history analyses with a set of twelve selected earthquake records. Twelve IMs and two types of seismic damage indices, namely, the maximum seismic response-based and energy-based parameters, are chosen as the examined indices. Selection criteria such as correlation, efficiency, and proficiency are considered in the selection process. The optimal IM is identified by means of a comprehensive evaluation using a large number of data of correlation, efficiency, and proficiency coefficients. Numerical results illustrate that peak ground velocity is the optimal one for long-period structures and peak ground displacement is also a close contender. As compared to previous reports, the spectral-correlated parameters can only be taken as moderate IMs. Moreover, the widely used peak ground acceleration in the current seismic codes is considered inappropriate for long-period structures.

  20. Absolute number density calibration of the absorption by ground-state lead atoms of the 283. 3-nm resonance line from a high-intensity lead hollow cathode lamp and the calculated effect of argon pressures

    SciTech Connect

    Simons, J.W.; McClean, R.E. ); Oldenborg, R.C. )

    1991-03-21

    The absolute number density calibration for the absorption by ground-state lead atoms of the 283.3-nm resonance line from a high-intensity lead hollow cathode lamp (Photron superlamp) is determined and found to be the same as that of a standard hollow cathode lamp. Comparisons of the calibrations to theoretical calculations are found to be quite satisfactory. The effects of argon pressures in the absorption cell on the calibration are examined theoretically by using a simple Lorentzian broadening and shifting model. These calculations show the expected reduction in sensitivity and increasing linearity of Beer-Lambert plots with increasing argon pressure.

  1. Measurement of the Absolute Magnitude and Time Courses of Mitochondrial Membrane Potential in Primary and Clonal Pancreatic Beta-Cells.

    PubMed

    Gerencser, Akos A; Mookerjee, Shona A; Jastroch, Martin; Brand, Martin D

    2016-01-01

    The aim of this study was to simplify, improve and validate quantitative measurement of the mitochondrial membrane potential (ΔψM) in pancreatic β-cells. This built on our previously introduced calculation of the absolute magnitude of ΔψM in intact cells, using time-lapse imaging of the non-quench mode fluorescence of tetramethylrhodamine methyl ester and a bis-oxonol plasma membrane potential (ΔψP) indicator. ΔψM is a central mediator of glucose-stimulated insulin secretion in pancreatic β-cells. ΔψM is at the crossroads of cellular energy production and demand, therefore precise assay of its magnitude is a valuable tool to study how these processes interplay in insulin secretion. Dispersed islet cell cultures allowed cell type-specific, single-cell observations of cell-to-cell heterogeneity of ΔψM and ΔψP. Glucose addition caused hyperpolarization of ΔψM and depolarization of ΔψP. The hyperpolarization was a monophasic step increase, even in cells where the ΔψP depolarization was biphasic. The biphasic response of ΔψP was associated with a larger hyperpolarization of ΔψM than the monophasic response. Analysis of the relationships between ΔψP and ΔψM revealed that primary dispersed β-cells responded to glucose heterogeneously, driven by variable activation of energy metabolism. Sensitivity analysis of the calibration was consistent with β-cells having substantial cell-to-cell variations in amounts of mitochondria, and this was predicted not to impair the accuracy of determinations of relative changes in ΔψM and ΔψP. Finally, we demonstrate a significant problem with using an alternative ΔψM probe, rhodamine 123. In glucose-stimulated and oligomycin-inhibited β-cells the principles of the rhodamine 123 assay were breached, resulting in misleading conclusions. PMID:27404273

  2. Measurement of the Absolute Magnitude and Time Courses of Mitochondrial Membrane Potential in Primary and Clonal Pancreatic Beta-Cells

    PubMed Central

    Gerencser, Akos A.; Mookerjee, Shona A.; Jastroch, Martin; Brand, Martin D.

    2016-01-01

    The aim of this study was to simplify, improve and validate quantitative measurement of the mitochondrial membrane potential (ΔψM) in pancreatic β-cells. This built on our previously introduced calculation of the absolute magnitude of ΔψM in intact cells, using time-lapse imaging of the non-quench mode fluorescence of tetramethylrhodamine methyl ester and a bis-oxonol plasma membrane potential (ΔψP) indicator. ΔψM is a central mediator of glucose-stimulated insulin secretion in pancreatic β-cells. ΔψM is at the crossroads of cellular energy production and demand, therefore precise assay of its magnitude is a valuable tool to study how these processes interplay in insulin secretion. Dispersed islet cell cultures allowed cell type-specific, single-cell observations of cell-to-cell heterogeneity of ΔψM and ΔψP. Glucose addition caused hyperpolarization of ΔψM and depolarization of ΔψP. The hyperpolarization was a monophasic step increase, even in cells where the ΔψP depolarization was biphasic. The biphasic response of ΔψP was associated with a larger hyperpolarization of ΔψM than the monophasic response. Analysis of the relationships between ΔψP and ΔψM revealed that primary dispersed β-cells responded to glucose heterogeneously, driven by variable activation of energy metabolism. Sensitivity analysis of the calibration was consistent with β-cells having substantial cell-to-cell variations in amounts of mitochondria, and this was predicted not to impair the accuracy of determinations of relative changes in ΔψM and ΔψP. Finally, we demonstrate a significant problem with using an alternative ΔψM probe, rhodamine 123. In glucose-stimulated and oligomycin-inhibited β-cells the principles of the rhodamine 123 assay were breached, resulting in misleading conclusions. PMID:27404273

  3. The oscillation model of hydrothermal dynamics beneath Aso volcano, southwest Japan after small eruption on May 2011: A new understanding model using repeated absolute and relative gravity measurement

    NASA Astrophysics Data System (ADS)

    Sofyan, Yayan; Nishijima, Jun; Fujimitsu, Yasuhiro; Yoshikawa, Shin; Kagiyama, Tsuneomi; Ohkura, Takahiro

    2016-01-01

    At the end of 2010, the seismic activity in Aso volcano intensely increased and water level in the Nakadake crater decreased until early in 2011, then was followed by a small eruption in May 2011. After the eruption and heavy rain, the volcanic activity subsided to calm period, crater bottom was refilled with water, and water level increased in the Nakadake crater. The next tremor reappeared in 2014 and tracked to eruption in November 2014. This eruptive pattern and water level variation in the crater repeatedly appeared on the surface, and it should be related to the hydrothermal dynamics beneath Aso volcano. We initiated the gravity measurements in relation to hydrothermal dynamics in the subsurface of Aso volcano using Scintrex CG-5 (549) and LaCoste Romberg type G-1016 relative gravimeter at 28 benchmarks in April 2011, one month before the eruption. The repeated gravity measurements continue to monitor Aso volcano with a series of the measurement after the eruption in every three months to a half year. We analyze the gravity variation from 2011 to 2014 between the time of the phreatic and strombolian eruption. The measurements covered the area more than 60 km2 in the west side of Aso caldera. A new gravity network was also installed in May 2010 at seven benchmarks using A10-017 absolute gravimeter, which re-occupied in October 2010, June 2011 and two benchmarks in June 2014. As a result, the gravity changes distinguish hydrothermal dynamic in the subsurface, which has a direct correlation to water level fluctuation in the crater, after the first eruption and before the second discharge. The monitoring data notice large gravity changes between the surveys at benchmarks around Nakadake crater and Kusasenri area. The simple 3D inversion models of the 4-D gravity data deduce the density contrast distribution beneath Aso volcano. The inversion and mass change result generate the oscillation typical as a new understanding model. The variation of the mass shows a

  4. Measuring absolute spin polarization in dissolution-DNP by Spin PolarimetrY Magnetic Resonance (SPY-MR).

    PubMed

    Vuichoud, Basile; Milani, Jonas; Chappuis, Quentin; Bornet, Aurélien; Bodenhausen, Geoffrey; Jannin, Sami

    2015-11-01

    Dynamic nuclear polarization at 1.2 K and 6.7 T allows one to achieve spin temperatures on the order of a few millikelvin, so that the high-temperature approximation (ΔEmeasuring spin polarizations 'on the fly' in a broad range of molecules, thus obviating the need for laborious measurements of signal intensities at thermal equilibrium. The method, dubbed Spin PolarimetrY Magnetic Resonance (SPY-MR), is illustrated for various pairs of (13)C spins (I, S) in acetate and pyruvate. PMID:26454350

  5. Measuring absolute spin polarization in dissolution-DNP by Spin PolarimetrY Magnetic Resonance (SPY-MR)

    NASA Astrophysics Data System (ADS)

    Vuichoud, Basile; Milani, Jonas; Chappuis, Quentin; Bornet, Aurélien; Bodenhausen, Geoffrey; Jannin, Sami

    2015-11-01

    Dynamic nuclear polarization at 1.2 K and 6.7 T allows one to achieve spin temperatures on the order of a few millikelvin, so that the high-temperature approximation (Δ E < kT) is violated for the nuclear Zeeman interaction Δ E = γB0h/(2 π) of most isotopes. Provided that, after rapid dissolution and transfer to an NMR or MRI system, the hyperpolarized molecules contain at least two nuclear spins I and S with a scalar coupling JIS, the polarization of spin I (short for 'investigated') can be determined from the asymmetry AS of the multiplet of spin S (short for 'spy'), provided perturbations due to second-order (strong coupling) effects are properly taken into account. If spin S is suitably discreet and does not affect the relaxation of spin I, this provides an elegant way of measuring spin polarizations 'on the fly' in a broad range of molecules, thus obviating the need for laborious measurements of signal intensities at thermal equilibrium. The method, dubbed Spin PolarimetrY Magnetic Resonance (SPY-MR), is illustrated for various pairs of 13 C spins (I, S) in acetate and pyruvate.

  6. Measuring absolute spin polarization in dissolution-DNP by Spin PolarimetrY Magnetic Resonance (SPY-MR).

    PubMed

    Vuichoud, Basile; Milani, Jonas; Chappuis, Quentin; Bornet, Aurélien; Bodenhausen, Geoffrey; Jannin, Sami

    2015-11-01

    Dynamic nuclear polarization at 1.2 K and 6.7 T allows one to achieve spin temperatures on the order of a few millikelvin, so that the high-temperature approximation (ΔEmeasuring spin polarizations 'on the fly' in a broad range of molecules, thus obviating the need for laborious measurements of signal intensities at thermal equilibrium. The method, dubbed Spin PolarimetrY Magnetic Resonance (SPY-MR), is illustrated for various pairs of (13)C spins (I, S) in acetate and pyruvate.

  7. On Removing Interloper Contamination from Intensity Mapping Power Spectrum Measurements

    NASA Astrophysics Data System (ADS)

    Lidz, Adam; Taylor, Jessie

    2016-07-01

    Line intensity mapping experiments seek to trace large-scale structures by measuring the spatial fluctuations in the combined emission, in some convenient spectral line, from individually unresolved galaxies. An important systematic concern for these surveys is line confusion from foreground or background galaxies emitting in other lines that happen to lie at the same observed frequency as the “target” emission line of interest. We develop an approach to separate this “interloper” emission at the power spectrum level. If one adopts the redshift of the target emission line in mapping from observed frequency and angle on the sky to co-moving units, the interloper emission is mapped to the wrong co-moving coordinates. Because the mapping is different in the line of sight and transverse directions, the interloper contribution to the power spectrum becomes anisotropic, especially if the interloper and target emission are at widely separated redshifts. This distortion is analogous to the Alcock–Paczynski test, but here the warping arises from assuming the wrong redshift rather than an incorrect cosmological model. We apply this to the case of a hypothetical [C ii] emission survey at z˜ 7 and find that the distinctive interloper anisotropy can, in principle, be used to separate strong foreground CO emission fluctuations. In our models, however, a significantly more sensitive instrument than currently planned is required, although there are large uncertainties in forecasting the high-redshift [C ii] emission signal. With upcoming surveys, it may nevertheless be useful to apply this approach after first masking pixels suspected of containing strong interloper contamination.

  8. On Removing Interloper Contamination from Intensity Mapping Power Spectrum Measurements

    NASA Astrophysics Data System (ADS)

    Lidz, Adam; Taylor, Jessie

    2016-07-01

    Line intensity mapping experiments seek to trace large-scale structures by measuring the spatial fluctuations in the combined emission, in some convenient spectral line, from individually unresolved galaxies. An important systematic concern for these surveys is line confusion from foreground or background galaxies emitting in other lines that happen to lie at the same observed frequency as the “target” emission line of interest. We develop an approach to separate this “interloper” emission at the power spectrum level. If one adopts the redshift of the target emission line in mapping from observed frequency and angle on the sky to co-moving units, the interloper emission is mapped to the wrong co-moving coordinates. Because the mapping is different in the line of sight and transverse directions, the interloper contribution to the power spectrum becomes anisotropic, especially if the interloper and target emission are at widely separated redshifts. This distortion is analogous to the Alcock-Paczynski test, but here the warping arises from assuming the wrong redshift rather than an incorrect cosmological model. We apply this to the case of a hypothetical [C ii] emission survey at z˜ 7 and find that the distinctive interloper anisotropy can, in principle, be used to separate strong foreground CO emission fluctuations. In our models, however, a significantly more sensitive instrument than currently planned is required, although there are large uncertainties in forecasting the high-redshift [C ii] emission signal. With upcoming surveys, it may nevertheless be useful to apply this approach after first masking pixels suspected of containing strong interloper contamination.

  9. Measured Absolute Cross Section of Charge Transfer in H + H2+ at Low Energy: Signature of vi = 2 and Trajectory Effects

    NASA Astrophysics Data System (ADS)

    Strom, R. A.; Bacani, K. G.; Chi, R. M.; Heczko, S. L.; Singh, B. N.; Tobar, J. A.; Vassantachart, A. K.; Andrianarijaona, V. M.; Seely, D. G.; Havener, C. C.

    2015-04-01

    Measurements of absolute cross sections of charge transfer (CT) in H + H2+--> H+ + H2 were conducted at the merged-beam apparatus at Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, which can reliably create and access collision energies as low as 0.1 eV/u. The measured absolute cross section shows evidence of trajectory effects at low energy. Also, the comparison to state-to-state calculations (PRA 67 022708 (2003) suggests a strong contribution from vi = 2 of the H2+that are produced by the electron cyclotron resonance ion source. The data analysis will be presented here. Research supported by the NASA Solar & Heliospheric Physics Program NNH07ZDA001N, the Office of Fusion Energy Sciences and the Division of Chemical Sciences, Geosciences, and Biosciences, Office of Basic Energy Sciences of the U.S. Department of Energy, the National Science Foundation through Grant No. PHY-1068877.

  10. Absolute measurement of subnanometer scale vibration of cochlear partition of an excised guinea pig cochlea using spectral-domain phase-sensitive optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Subhash, Hrebesh M.; Choudhury, Niloy; Jacques, Steven L.; Wang, Ruikang K.; Chen, Fangyi; Zha, Dingjun; Nuttall, Alfred L.

    2012-01-01

    Direct measurement of absolute vibration parameters from different locations within the mammalian organ of Corti is crucial for understanding the hearing mechanics such as how sound propagates through the cochlea and how sound stimulates the vibration of various structures of the cochlea, namely, basilar membrane (BM), recticular lamina, outer hair cells and tectorial membrane (TM). In this study we demonstrate the feasibility a modified phase-sensitive spectral domain optical coherence tomography system to provide subnanometer scale vibration information from multiple angles within the imaging beam. The system has the potential to provide depth resolved absolute vibration measurement of tissue microstructures from each of the delay-encoded vibration images with a noise floor of ~0.3nm at 200Hz.

  11. Systematic Uncertainties in the Spectroscopic Measurements of Neutron-star Masses and Radii from Thermonuclear X-Ray Bursts. III. Absolute Flux Calibration

    NASA Astrophysics Data System (ADS)

    Güver, Tolga; Özel, Feryal; Marshall, Herman; Psaltis, Dimitrios; Guainazzi, Matteo; Díaz-Trigo, Maria

    2016-09-01

    Many techniques for measuring neutron star radii rely on absolute flux measurements in the X-rays. As a result, one of the fundamental uncertainties in these spectroscopic measurements arises from the absolute flux calibrations of the detectors being used. Using the stable X-ray burster, GS 1826-238, and its simultaneous observations by Chandra HETG/ACIS-S and RXTE/PCA as well as by XMM-Newton EPIC-pn and RXTE/PCA, we quantify the degree of uncertainty in the flux calibration by assessing the differences between the measured fluxes during bursts. We find that the RXTE/PCA and the Chandra gratings measurements agree with each other within their formal uncertainties, increasing our confidence in these flux measurements. In contrast, XMM-Newton EPIC-pn measures 14.0 ± 0.3% less flux than the RXTE/PCA. This is consistent with the previously reported discrepancy with the flux measurements of EPIC-pn, compared with EPIC MOS1, MOS2, and ACIS-S detectors. We also show that any intrinsic time-dependent systematic uncertainty that may exist in the calibration of the satellites has already been implicity taken into account in the neutron star radius measurements.

  12. Absolute calibration of the Auger fluorescence detectors

    SciTech Connect

    Bauleo, P.; Brack, J.; Garrard, L.; Harton, J.; Knapik, R.; Meyhandan, R.; Rovero, A.C.; Tamashiro, A.; Warner, D.

    2005-07-01

    Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the combined effects of all detector components in a single measurement. The calibrated 2.5 m diameter light source fills the aperture, providing uniform illumination to each pixel. The known flux from the light source and the response of the acquisition system give the required calibration for each pixel. In the lab, light source uniformity is studied using CCD images and the intensity is measured relative to NIST-calibrated photodiodes. Overall uncertainties are presently 12%, and are dominated by systematics.

  13. Prism-pair interferometry by homodyne interferometers with a common light source for high-accuracy measurement of the absolute refractive index of glasses

    SciTech Connect

    Hori, Yasuaki; Hirai, Akiko; Minoshima, Kaoru

    2011-03-10

    A prism-pair interferometer comprising two homodyne interferometers with a common light source was developed for high-precision measurements of the refractive index of optical glasses with an uncertainty of the order of 10{sup -6}. The two interferometers measure changes in the optical path length in the glass sample and in air, respectively. Uncertainties in the absolute wavelength of the common light source are cancelled out by calculating a ratio between the results from the interferometers. Uncertainties in phase measurement are suppressed by a quadrature detection system. The combined standard uncertainty of the developed system is evaluated as 1.1x10{sup -6}.

  14. Dispersive white light combined with a frequency-modulated continuous-wave interferometer for high-resolution absolute measurements of distance.

    PubMed

    Rovati, L; Minoni, U; Docchio, F

    1997-06-15

    A nonincremental interferometer for the absolute measurement of distances is presented. The measuring technique is based on both dispersive white-light (DWL) interferometry and frequency-modulated continuous-wave (FMCW) interferometry. The proposed configuration integrates both techniques in the same interferometer by use of a single laser diode. This solution enables the results from the coarse measurements from the FMCW interferometer to be combined with the fine readouts from the DWL interferometer. Preliminary experimental results confirm the capability of the system to combine the advantages of the two techniques. PMID:18185683

  15. Absolute measurement of the photoionization cross section of atomic hydrogen with a shock tube for the extreme ultraviolet. [for astrophysical applications

    NASA Technical Reports Server (NTRS)

    Palenius, H. P.; Kohl, J. L.; Parkinson, W. H.

    1976-01-01

    The paper reports an experiment which is part of a program to measure the absolute values of the atomic photoionization cross sections of astrophysically abundant elements, particularly in stars and planetary atmospheres. An aerodynamic pressure-driven shock tube constructed from stainless steel with a quadratic cross section was used to measure the photoionization cross section of H I at 19 wavelength points from 910 to 609 A with experimental uncertainties between 7 and 20%. The shock tube was used to produce fully dissociated hydrogen and neon mixtures for the photoabsorption measurements.

  16. Splitting intensity measurements of North America and finite-frequency modeling of upper mantle anisotropy

    NASA Astrophysics Data System (ADS)

    Hongsresawat, Sutatcha

    The central theme of this dissertation is to investigate the interaction between the overlying lithospheric plates and the hotter and more deformable asthenosphere to examine how they are coupled. The answer will have very significant implications because the coupled lithosphere-asthenosphere setting predicts shear beneath the lithosphere which drives large-scale mantle convection, a widely-accepted schematic for modern mantle convection research. In our research, the primary tool to examine this coupled interaction is anisotropy in the upper mantle observed via shear wave splitting. The first research component involves measuring splitting intensity (SI) of the core-refracted shear waves (SKS) observed at 1,436 USArray Transportable Array (USArray-TA) seismic stations which cover most of the contiguous U.S. By fitting a sinusoidal to the back-azimuthal dependence of splitting intensity, traditional splitting parameters, the polarization angle between the radial direction and the fast axis, φ, and the delay time between the fast and slow polarizations, deltat, are obtained and used in comparison with absolute plate motion (APM), geological basement provinces, magnetic, gravity anomalies and lithospheric thickness to reveal the interactions between asthenospheric flow and lithospheric anisotropic structures of several geological regions of North America. Preliminary results shows that the Rocky Mountain front has a complicated flow due to transition with thickness along APM flow, the Gulf Coast has a strong APM asthenospheric signature in region of thin lithosphere and the northern Central U.S. has complicated interactions between asthenosphere and lithosphere. We observe a notable contrast between the Superior Province vs. Trans-Hudson where lithospheric texture alignment plays an important role in adding vs. subtracting the splitting signals. The next component of our research focuses on the Idaho-Oregon (IDOR) region. This region is an assemblage of several

  17. Measurement of the absorption coefficient using the sound-intensity technique

    NASA Technical Reports Server (NTRS)

    Atwal, M.; Bernhard, R.

    1984-01-01

    The possibility of using the sound intensity technique to measure the absorption coefficient of a material is investigated. This technique measures the absorption coefficient by measuring the intensity incident on the sample and the net intensity reflected by the sample. Results obtained by this technique are compared with the standard techniques of measuring the change in the reverberation time and the standing wave ratio in a tube, thereby, calculating the random incident and the normal incident adsorption coefficient.

  18. [Measuring the sources of discomfort in patients in intensive care].

    PubMed

    Haubertin, Carole; Crozes, Fanny; Le Page, Melody; Seailles, Severine

    2016-05-01

    A study carried out in 2014 in a hospital focused on the sources of discomfort of patients in intensive care. Resulting in raised awareness across all disciplines, it has enabled the actions to be undertaken to improve professional practices to be prioritised, in a culture of compassionate care. PMID:27157560

  19. Measurement of the absorption coefficient of acoustical materials using the sound intensity method

    NASA Technical Reports Server (NTRS)

    Atwal, Mahabir S.; Crocker, Malcolm J.

    1987-01-01

    In this study the possibility of using the two-microphone sound intensity technique to measure the normal incidence and the random incidence sound absorption coefficient was investigated. The normal incidence absorption coefficient was determined by measuring the intensity incidence on the sample and the intensity reflected by the sample placed in an anechoic chamber. The random incidence absorption coefficient was determined by measuring the intensity incident on the sample and the intensity reflected by the sample placed in a reverberation chamber. Absorption coefficient results obtained by the sound intensity technique were compared with standard techniques, namely the reverberation chamber and the standing wave tube. The major advantages of using the sound intensity technique are that it permits 'in situ' measurements and the absorption coefficient for a large range of frequencies can be obtained from a single measurement.

  20. Measurement of absolute cell volume, osmotic membrane water permeability, and refractive index of transmembrane water and solute flux by digital holographic microscopy.

    PubMed

    Boss, Daniel; Kühn, Jonas; Jourdain, Pascal; Depeursinge, Christian; Magistretti, Pierre J; Marquet, Pierre

    2013-03-01

    A dual-wavelength digital holographic microscope to measure absolute volume of living cells is proposed. The optical setup allows us to reconstruct two quantitative phase contrast images at two different wavelengths from a single hologram acquisition. When adding the absorbing dye fast green FCF as a dispersive agent to the extracellular medium, cellular thickness can be univocally determined in the full field of view. In addition to the absolute cell volume, the method can be applied to derive important biophysical parameters of living cells including osmotic membrane water permeability coefficient and the integral intracellular refractive index (RI). Further, the RI of transmembrane flux can be determined giving an indication about the nature of transported solutes. The proposed method is applied to cultured human embryonic kidney cells, Chinese hamster ovary cells, human red blood cells, mouse cortical astrocytes, and neurons. PMID:23487181

  1. Determination of the absolute configuration of perylene quinone-derived mycotoxins by measurement and calculation of electronic circular dichroism spectra and specific rotations.

    PubMed

    Podlech, Joachim; Fleck, Stefanie C; Metzler, Manfred; Bürck, Jochen; Ulrich, Anne S

    2014-09-01

    Altertoxins I-III, alterlosins I and II, alteichin (alterperylenol), stemphyltoxins I-IV, stemphyperylenol, stemphytriol, 7-epi-8-hydroxyaltertoxin I, and 6-epi-stemphytriol are mycotoxins derived from perylene quinone, for which the absolute configuration was not known. Electronic circular dichroism (ECD) spectra were calculated for these compounds and compared with measured spectra of altertoxins I-III, alteichin, and stemphyltoxin III and with reported Cotton effects. Specific rotations were calculated and compared with reported specific rotations. The absolute configuration of all the toxins, except for stemphyltoxin IV, could thus be determined. The validity of the assignment was high whenever reported ECD data were available for comparison, and the validity was lower when the assignment was based only on the comparison of calculated and reported specific rotations. ECD spectra are intrinsically different for toxins with a biphenyl substructure and for toxins derived from dihydroanthracene.

  2. Using Multivariate Regression Model with Least Absolute Shrinkage and Selection Operator (LASSO) to Predict the Incidence of Xerostomia after Intensity-Modulated Radiotherapy for Head and Neck Cancer

    PubMed Central

    Ting, Hui-Min; Chang, Liyun; Huang, Yu-Jie; Wu, Jia-Ming; Wang, Hung-Yu; Horng, Mong-Fong; Chang, Chun-Ming; Lan, Jen-Hong; Huang, Ya-Yu; Fang, Fu-Min; Leung, Stephen Wan

    2014-01-01

    Purpose The aim of this study was to develop a multivariate logistic regression model with least absolute shrinkage and selection operator (LASSO) to make valid predictions about the incidence of moderate-to-severe patient-rated xerostomia among head and neck cancer (HNC) patients treated with IMRT. Methods and Materials Quality of life questionnaire datasets from 206 patients with HNC were analyzed. The European Organization for Research and Treatment of Cancer QLQ-H&N35 and QLQ-C30 questionnaires were used as the endpoint evaluation. The primary endpoint (grade 3+ xerostomia) was defined as moderate-to-severe xerostomia at 3 (XER3m) and 12 months (XER12m) after the completion of IMRT. Normal tissue complication probability (NTCP) models were developed. The optimal and suboptimal numbers of prognostic factors for a multivariate logistic regression model were determined using the LASSO with bootstrapping technique. Statistical analysis was performed using the scaled Brier score, Nagelkerke R2, chi-squared test, Omnibus, Hosmer-Lemeshow test, and the AUC. Results Eight prognostic factors were selected by LASSO for the 3-month time point: Dmean-c, Dmean-i, age, financial status, T stage, AJCC stage, smoking, and education. Nine prognostic factors were selected for the 12-month time point: Dmean-i, education, Dmean-c, smoking, T stage, baseline xerostomia, alcohol abuse, family history, and node classification. In the selection of the suboptimal number of prognostic factors by LASSO, three suboptimal prognostic factors were fine-tuned by Hosmer-Lemeshow test and AUC, i.e., Dmean-c, Dmean-i, and age for the 3-month time point. Five suboptimal prognostic factors were also selected for the 12-month time point, i.e., Dmean-i, education, Dmean-c, smoking, and T stage. The overall performance for both time points of the NTCP model in terms of scaled Brier score, Omnibus, and Nagelkerke R2 was satisfactory and corresponded well with the expected values. Conclusions

  3. Improved Beach Zone Segmentation From Airborne Lidar Measurements Using Intensity Measures

    NASA Astrophysics Data System (ADS)

    Starek, M. J.; Vemula, R. K.; Slatton, C.; Shrestha, R. L.; Carter, W. E.

    2007-05-01

    In an effort to monitor beach zone stability along the St. Augustine Beach region of Florida, high-resolution airborne laser swath mapping (ALSM) data are routinely acquired by the University of Florida's Geosensing and Engineering Mapping (GEM) Center. ALSM, often referred to as Light Detection and Ranging (LiDAR), systems enable sub-meter sampling of the near-shore coastal topography and the subsequent creation of digital elevation images with rms errors of less than 10cm over minimally-vegetated surfaces, such as beaches. Currently, there are seven collection dates spanning August 2003 to February 2007. This high spatial resolution coupled with the multiple acquisitions through time provided several results: two separate beach nourishment efforts were captured in the data allowing sediment spreading rate to be modeled and volume loss quantified, shoreline change rates were estimated for temporal scales ranging from a few months to over two years at various spatial frequencies from < 5m to > 300m, storm and seasonal wave climate induced shoreline response were modeled, and novel approaches to morphological feature extraction and identification of localized erosional hot- spots were developed. All previous analyses are based on range measurements; however, the ALSM system also records the intensity (peak voltage from the APD) for each return. Intensity has traditionally been under utilized as a feature for image classification because it does not represent true terrain radiance. We show that in areas with minimal topographic relief, such as beaches, intensity measures have great potential for improved beach zone segmentation. Segmentation of the beach zone is important for several factors including identification of the wet-dry line for traditional shoreline comparison and change-detection, and removal of water points to allow analysis of beach-only zones. Several intensity-based features are extracted from ALSM training data collected along the St. Augustine

  4. Improved method for measuring absolute O2(a1Δg) concentration by O2(a1Δg-->X3Σg-) IR radiation

    NASA Astrophysics Data System (ADS)

    Deng, Liezheng; Shi, Wenbo; Yang, Heping; Sha, Guohe; Zhang, Cunhao

    2004-11-01

    We describe an improved technique for measuring the absolute O2(a1Δ) concentration via the quantitative determination of IR radiation from O2(a1Δg→X3Σg-) transition. An exact geometrical optical model was first established, in which the influence of reflection and refraction on the radiation characteristics of a luminous volume source was given full consideration, making possible the accurate calculation of the coupling efficiency between the volume source and a receiving area. Then, an IR radiation receiving apparatus (IRRRA) was constructed and its responsivity (mV/W) to the power of IR radiation calibrated by a tungsten standard lamp. An optical detection system was, in turn, built according to the optical model with fine alignment between the IRRRA and an optical cell. We then demonstrate the procedure to obtain the absolute concentration of O2(a1Δ) flowing through the optical cell from a jet singlet oxygen generator from the signal of the IRRRA, the optical cell volume, and the coupling efficiency between the cell and the IRRRA. Moreover, to verify the accuracy of this method, the absolute O2(a1Δ) concentration was compared to that measured by an established isothermal calorimetry method. Based on the comparison of the O2(a1Δ) concentrations determined by the two methods, the Einstein A-coefficient was estimated as (2.70±0.84)×10-4 s-1, which agrees with Badger's value of 2.58×10-4, Špalek's of 2.24×10-4, Newman's of 2.19×10-4, and Miller's of 2.3×10-4 within the uncertainty of the experimental techniques. The method advanced in this article is worthwhile for the measurement of absolute O2(a1Δ) concentration in a chemical oxygen iodine laser or a singlet oxygen generator. It can also provide a general technique for the measurement of absolute concentrations of long-lifetime luminous species other than O2(a1Δ).

  5. Absolute measurement of cerebral optical coefficients, hemoglobin concentration and oxygen saturation in old and young adults with near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Hallacoglu, Bertan; Sassaroli, Angelo; Wysocki, Michael; Guerrero-Berroa, Elizabeth; Schnaider Beeri, Michal; Haroutunian, Vahram; Shaul, Merav; Rosenberg, Irwin H.; Troen, Aron M.; Fantini, Sergio

    2012-08-01

    We present near-infrared spectroscopy measurement of absolute cerebral hemoglobin concentration and saturation in a large sample of 36 healthy elderly (mean age, 85±6 years) and 19 young adults (mean age, 28±4 years). Non-invasive measurements were obtained on the forehead using a commercially available multi-distance frequency-domain system and analyzed using a diffusion theory model for a semi-infinite, homogeneous medium with semi-infinite boundary conditions. Our study included repeat measurements, taken five months apart, on 16 elderly volunteers that demonstrate intra-subject reproducibility of the absolute measurements with cross-correlation coefficients of 0.9 for absorption coefficient (μa), oxy-hemoglobin concentration ([HbO2]), and total hemoglobin concentration ([HbT]), 0.7 for deoxy-hemoglobin concentration ([Hb]), 0.8 for hemoglobin oxygen saturation (StO2), and 0.7 for reduced scattering coefficient (). We found significant differences between the two age groups. Compared to young subjects, elderly subjects had lower cerebral [HbO2], [Hb], [HbT], and StO2 by 10±4 μM, 4±3 μM, 14±5 μM, and 6%±5%, respectively. Our results demonstrate the reliability and robustness of multi-distance near-infrared spectroscopy measurements based on a homogeneous model in the human forehead on a large sample of human subjects. Absolute, non-invasive optical measurements on the brain, such as those presented here, can significantly advance the development of NIRS technology as a tool for monitoring resting/basal cerebral perfusion, hemodynamics, oxygenation, and metabolism.

  6. Prospects for UT1 Measurements from VLBI Intensive Sessions

    NASA Technical Reports Server (NTRS)

    Boehm, Johannes; Nilsson, Tobias; Schuh, Harald

    2010-01-01

    Very Long Baseline Interferometry (VLBI) Intensives are one-hour single baseline sessions to provide Universal Time (UT1) in near real-time up to a delay of three days if a site is not e-transferring the observational data. Due to the importance of UT1 estimates for the prediction of Earth orientation parameters, as well as any kind of navigation on Earth or in space, there is not only the need to improve the timeliness of the results but also their accuracy. We identify the asymmetry of the tropospheric delays as the major error source, and we provide two strategies to improve the results, in particular of those Intensives which include the station Tsukuba in Japan with its large tropospheric variation. We find an improvement when (1) using ray-traced delays from a numerical weather model, and (2) when estimating tropospheric gradients within the analysis of Intensive sessions. The improvement is shown in terms of reduction of rms of length-of-day estimates w.r.t. those derived from Global Positioning System observations

  7. Delineating the major KREEP-bearing terranes on the moon with global measurements of absolute thorium abundances

    SciTech Connect

    Lawrence, D.J.; Feldman, W.C.; Barraclough, B.L.; Elphic, R.C.; Prettyman, T.H.; Binder, A.B.; Maurice, S.; Miller, M.C.

    1999-03-01

    The Lunar Prospector (LP) Gamma-Ray Spectrometer (GRS) has been used to map the global composition of thorium on the lunar surface. Previous LP results of relative thorium abundances demonstrated that thorium is highly concentrated in and around the nearside western maria and less so in the South Pole Aitken (SPA) basin. Using new detector modeling results and a larger data set, the authors present here a global map of absolute thorium abundances on a 2{degree} by 2{degree} equal-area pixel scale. Because thorium is a tracer of KREEP-rich material, these data provide fundamental information regarding the locations and importance of terranes that are rich in KREEP bearing materials.

  8. A novel double-focusing time-of-flight mass spectrometer for absolute recoil ion cross sections measurements.

    PubMed

    Sigaud, L; de Jesus, V L B; Ferreira, Natalia; Montenegro, E C

    2016-08-01

    In this work, the inclusion of an Einzel-like lens inside the time-of-flight drift tube of a standard mass spectrometer coupled to a gas cell-to study ionization of atoms and molecules by electron impact-is described. Both this lens and a conical collimator are responsible for further focalization of the ions and charged molecular fragments inside the spectrometer, allowing a much better resolution at the time-of-flight spectra, leading to a separation of a single mass-to-charge unit up to 100 a.m.u. The procedure to obtain the overall absolute efficiency of the spectrometer and micro-channel plate detector is also discussed. PMID:27587105

  9. A novel double-focusing time-of-flight mass spectrometer for absolute recoil ion cross sections measurements.

    PubMed

    Sigaud, L; de Jesus, V L B; Ferreira, Natalia; Montenegro, E C

    2016-08-01

    In this work, the inclusion of an Einzel-like lens inside the time-of-flight drift tube of a standard mass spectrometer coupled to a gas cell-to study ionization of atoms and molecules by electron impact-is described. Both this lens and a conical collimator are responsible for further focalization of the ions and charged molecular fragments inside the spectrometer, allowing a much better resolution at the time-of-flight spectra, leading to a separation of a single mass-to-charge unit up to 100 a.m.u. The procedure to obtain the overall absolute efficiency of the spectrometer and micro-channel plate detector is also discussed.

  10. A novel double-focusing time-of-flight mass spectrometer for absolute recoil ion cross sections measurements

    NASA Astrophysics Data System (ADS)

    Sigaud, L.; de Jesus, V. L. B.; Ferreira, Natalia; Montenegro, E. C.

    2016-08-01

    In this work, the inclusion of an Einzel-like lens inside the time-of-flight drift tube of a standard mass spectrometer coupled to a gas cell—to study ionization of atoms and molecules by electron impact—is described. Both this lens and a conical collimator are responsible for further focalization of the ions and charged molecular fragments inside the spectrometer, allowing a much better resolution at the time-of-flight spectra, leading to a separation of a single mass-to-charge unit up to 100 a.m.u. The procedure to obtain the overall absolute efficiency of the spectrometer and micro-channel plate detector is also discussed.

  11. Psychometric Properties of the Affect Intensity and Reactivity Measure Adapted for Youth (AIR-Y)

    ERIC Educational Resources Information Center

    Jones, Rachel E.; Leen-Feldner, Ellen W.; Olatunji, Bunmi O.; Reardon, Laura E.; Hawks, Erin

    2009-01-01

    A valid and reliable instrument for measuring affect intensity does not exist for adolescents; such a measure may help to refine understanding of emotion among youths. The purpose of the current study was to evaluate the psychometric properties and clinical relevance of a measure of affect intensity adapted for youths. Two hundred five community…

  12. Student Award Finalist: Reactive species generated in atmospheric-pressure plasmas with water admixtures for biomedical applications: Absolute measurements and numerical simulations

    NASA Astrophysics Data System (ADS)

    Schröter, Sandra; Bredin, J.; West, A.; Niemi, K.; Dedrick, J.; de Oliveira, N.; Joyeux, D.; Nahon, L.; Foucher, M.; Booth, J.-P.; Wagenaars, E.; Gans, T.; O'Connell, D.

    2015-09-01

    We investigate the production of atomic oxygen (O), hydroxyl (OH) and atomic hydrogen (H) in an rf atmospheric-pressure plasma operated in helium with water admixtures. These species, and their longer-lived products, are known to influence biological systems. Absolute measurements of species densities are required to develop these plasmas for therapeutics. Accurate determination of radical densities is challenging at elevated pressures in complex gas mixtures due to collisional quenching. We measure radical densities using VUV high-resolution Fourier-transform absorption spectroscopy with synchrotron radiation, UV broadband absorption spectroscopy, and picosecond two-photon absorption laser induced fluorescence (ps-TALIF). These diagnostics are the most suitable techniques allowing direct, absolute and 2-dimensional spatial resolution measurements at atmospheric pressure. Ps-TALIF also enables measurements of the lifetimes of laser-excited states of O and H, providing insight into the chemical kinetics and ambient air diffusion into the plasma jet region. Good agreement has been found between the measurements and a numerical chemical-kinetic simulation. Funding from the UK EPSRC (EP/K018388/1 & EP/H003797/1), the York-Paris Low Temperature Plasma Collaborative Research Centre and financial state aid managed by the laboratory of excellence Plas@Par (ANR-11-IDEX-0004-02).

  13. Burnett Method with Absolute Pressure Transducer and Measurements for PVT Properties of Nitrogen and Hydrogen up to 473 K and 100 MPa

    NASA Astrophysics Data System (ADS)

    Sakoda, N.; Shindo, K.; Motomura, K.; Shinzato, K.; Kohno, M.; Takata, Y.; Fujii, M.

    2012-01-01

    A measurement method for PVT properties of high-temperature and high-pressure gases was developed by simplifying the Burnett method and revising the data acquisition procedure. Instead of a differential pressure transducer, which is traditionally used, an absolute pressure transducer is used in the present method, and the measurement of pressure becomes easier. However, the absolute pressure transducer is placed outside the constant temperature bath because of the difficulty of its use in high-temperature surroundings, and some parts with different temperatures from the sample vessels exist as dead space. The present method takes into account the effect of the dead space in the data acquisition procedure. Nitrogen was measured in the temperature range from 353 K to 473 K and at pressures up to 100 MPa to determine the apparatus constants, and then, hydrogen was measured at 473 K and up to 100 MPa. The determined densities are in agreement within uncertainties of 0.07% to 0.24% ( k = 2), both with the latest equation of state and existing measured data.

  14. The near wall TIRFM measurement of nano-tracer's statistical intensity distribution (SID) and determining the base intensity I0

    NASA Astrophysics Data System (ADS)

    Zheng, Xu; LNM Team

    2015-11-01

    The total internal reflection fluorescence microscopy (TIRFM) is an evanescent-wave-based technique for measuring nanoparticle dynamics very close to wall. The intensity of the evanescent wave decays exponentially (i.e. I(z) =I0exp(z/zp)) , which can provide information of the tracer particle position not just parallel but also normal to wall. However, considering the z information is encoded in tracer intensity, it is critical to determine the base intensity I0. In this study, we will first establish a model to describe the statistical intensity distribution (SID) of the nano-tracers observed in the evanescent field inspired by the works of Huang et al. A different function of particle-wall interaction and a term of the influence of the objective focal plane thickness are introduced in the present SID method. Then, TIRFM experiments are performed to measure the histogram of SID. The experimental histogram of SID is then fitted by the theoretical curve to determine I0 which is the only one fit parameter. By near wall velocity measurement, we will show that the SID method has a very high precision in determining I0 and the vertical z position of every nanotracer. Further tests show that the PDF of nano-tracers can reveal more information about how nanoparticles interact with the charged solid wall. This provides a promising method to detect the physical properties near interface.

  15. Teaching Absolute Value Meaningfully

    ERIC Educational Resources Information Center

    Wade, Angela

    2012-01-01

    What is the meaning of absolute value? And why do teachers teach students how to solve absolute value equations? Absolute value is a concept introduced in first-year algebra and then reinforced in later courses. Various authors have suggested instructional methods for teaching absolute value to high school students (Wei 2005; Stallings-Roberts…

  16. Measurements of x-ray spectral flux and intensity distribution of APS/CHESS undulator radiation

    SciTech Connect

    Ilinski, P.; Yun, W.; Lai, B.; Gluskin, E.; Cai, Z.

    1994-09-01

    Absolute radiation flux and polarization measurements of the APS undulators may have to be made under high thermal loading conditions. A method that may circumvent the high-heat-load problem was tested during a recent APS/CHESS undulator run. The technique makes use of a Si(Li) energy-dispersive detector to measure 5--35 keV x-rays scattered from a well-defined He gas volume at controlled pressure.

  17. EUV line intensities above the limb measured by CDS

    NASA Technical Reports Server (NTRS)

    Fludra, A.; DelZanna, G.; Bromage, B. J. I.; Thomas, R. J.

    1997-01-01

    The extreme ultraviolet (EUV) above the limb observed with the coronal diagnostic spectrometer (CDS) are discussed. The CDS spectra were obtained up to 0.3 solar radii above the east and west limb, and above the polar coronal holes. A large data set was acquired during the campaign in August 1996. The intensities of the chromospheric, transition region and coronal lines were derived as a function of the radial distance. The density-sensitive line ratios of Si IX 350/342 A and Si X 356/347 A were used to derive an average electron density. The temperature and density in the coronal holes were found to be lower than in the closed field regions.

  18. Thermal parameters measurement on fire fighter during intense fire exposition.

    PubMed

    Oliveira, A; Gehin, C; Delhomme, G; Dittmar, A; McAdams, E

    2009-01-01

    To improve rescuer safety, coordination and efficiency, the European program ProeTEX aims at developing new equipment for the intervention staff. This equipment is based on micro and nanotechnologies and consisted of smart textile integrated sensor to monitor physiological parameters, environment of the rescuer but also acquisition module and communication module. Thermal parameters are of primer interest. Internal temperature, external temperature and heat flux are relevant parameters to prevent heat stroke in fire fighter when exposed to intense fire. These parameters are recorded during fire exposition and highlight, on one hand, that the outer garment of fire fighters' equipment insulates the fire fighter from the external environment, and on the other hand, that the thermal monitoring is relevant. PMID:19963808

  19. Using A New Model for Main Sequence Turnoff Absolute Magnitudes to Measure Stellar Streams in the Milky Way Halo

    NASA Astrophysics Data System (ADS)

    Weiss, Jake; Newberg, Heidi Jo; Arsenault, Matthew; Bechtel, Torrin; Desell, Travis; Newby, Matthew; Thompson, Jeffery M.

    2016-01-01

    Statistical photometric parallax is a method for using the distribution of absolute magnitudes of stellar tracers to statistically recover the underlying density distribution of these tracers. In previous work, statistical photometric parallax was used to trace the Sagittarius Dwarf tidal stream, the so-called bifurcated piece of the Sagittaritus stream, and the Virgo Overdensity through the Milky Way. We use an improved knowledge of this distribution in a new algorithm that accounts for the changes in the stellar population of color-selected stars near the photometric limit of the Sloan Digital Sky Survey (SDSS). Although we select bluer main sequence turnoff stars (MSTO) as tracers, large color errors near the survey limit cause many stars to be scattered out of our selection box and many fainter, redder stars to be scattered into our selection box. We show that we are able to recover parameters for analogues of these streams in simulated data using a maximum likelihood optimization on MilkyWay@home. We also present the preliminary results of fitting the density distribution of major Milky Way tidal streams in SDSS data. This research is supported by generous gifts from the Marvin Clan, Babette Josephs, Manit Limlamai, and the MilkyWay@home volunteers.

  20. Qualitative analysis of the magnetic data collected by the Embrace MagNet in comparison to absolute measurements made by Intermagnet in Vassouras-RJ

    NASA Astrophysics Data System (ADS)

    Chen, Sony Su; Moro, Juliano; Araujo Resende, Laysa Cristina; Denardini, Clezio Marcos

    2016-07-01

    The Embrace Magnetometer Network (Embrace MagNet) is a network of three-axis fluxgate magnetometers using single bars with high level of magnetic saturation, covered with two copper coils, one for the excitation and the second for sensing the external field. It is planned to cover most of the Easter Southern American longitudinal sector in order to fulfill the gap for magnetic measurement available on-line. The availability of fast internet, reliable energy supply and easy access were the key point for deciding the location of the magnetometer stations of the network. Up to now, the main characteristic of this network is the severe sensibility matching process among all the magnetometers composing it. Now, in order to validate the magnetic data collected by the elements of the Embrace MagNet in comparison to absolute measurements, we performed a study about the correlation between the data collected by the fluxgate magnetometer provided by Embrace MagNet and an absolute magnetometer installed by Intermagnet in the same observatory. For this study, we have used data collected in Vassouras-RJ, in Brazil, covering the period from June to December 2015. The analysis consist of: (a) selecting the 5 quietest days and the 5 most disturbed days of each month based on the Kp index; (b) deducing the local midnight value from the data collected by both instruments; (c) correlating the data collected by the variometer with the absolute measurement day-by-day; (d) grouping the results as Winter (June, July, and August), Equinox (September and October) and Summer (November and December); (e) obtaining the linear correlations factor for each group. The averaged correlation factors and the daily variations of the magnetic data are presented and discussed in terms of the magnetic activity and the season variation.

  1. Absolute measurement of the total ion-drag force on a single plasma-confined microparticle at the void edge under microgravity conditions.

    PubMed

    Beckers, J; Trienekens, D J M; Kroesen, G M W

    2013-11-01

    We present an absolute measurement of the total ion-drag force on one single microparticle at the edge of the dust free region in low pressure complex plasmas: the void. In order to do so, the particle confinement position was monitored as a function of the gas pressure for two particle sizes under normal gravity conditions and under microgravity conditions during parabolic flights. At the border of the void, the ion-drag force on a particle with a radius of 4.90 μm appeared to be (3.6±0.3)×10(-12) N.

  2. Automatic gonio-spectrophotometer for the absolute measurement of the spectral BRDF at in- and out-of-plane and retroreflection geometries

    NASA Astrophysics Data System (ADS)

    Rabal, A. M.; Ferrero, A.; Campos, J.; Fontecha, J. L.; Pons, A.; Rubiño, A. M.; Corróns, A.

    2012-06-01

    This paper presents the description and the characterization of the gonio-spectrophotometer GEFE (the acronym for 'Gonio-EspectroFotómetro Español'). This device has been designed and built for the low-uncertainty absolute measurement of the bidirectional reflectance distribution function (BRDF). It comprises a fixed, collimated and uniform light source, a six-axis robot-arm to rotate the sample and a spectroradiometer that may revolve around the sample to be able to vary the source-to-detector angular separation. This gonio-spectrophotometer makes it possible to perform spectral measurements in the visible range, both inside and outside the incidence plane, as well as measurements in retroreflection conditions. This fully automated system is able to measure autonomously a sample's complete spectral BRDF (comprising around 1000 different angular configurations) in less than 4 h.

  3. ABSOLUTE POLARIMETRY AT RHIC.

    SciTech Connect

    OKADA; BRAVAR, A.; BUNCE, G.; GILL, R.; HUANG, H.; MAKDISI, Y.; NASS, A.; WOOD, J.; ZELENSKI, Z.; ET AL.

    2007-09-10

    Precise and absolute beam polarization measurements are critical for the RHIC spin physics program. Because all experimental spin-dependent results are normalized by beam polarization, the normalization uncertainty contributes directly to final physics uncertainties. We aimed to perform the beam polarization measurement to an accuracy Of {Delta}P{sub beam}/P{sub beam} < 5%. The absolute polarimeter consists of Polarized Atomic Hydrogen Gas Jet Target and left-right pairs of silicon strip detectors and was installed in the RHIC-ring in 2004. This system features proton-proton elastic scattering in the Coulomb nuclear interference (CNI) region. Precise measurements of the analyzing power A{sub N} of this process has allowed us to achieve {Delta}P{sub beam}/P{sub beam} = 4.2% in 2005 for the first long spin-physics run. In this report, we describe the entire set up and performance of the system. The procedure of beam polarization measurement and analysis results from 2004-2005 are described. Physics topics of AN in the CNI region (four-momentum transfer squared 0.001 < -t < 0.032 (GeV/c){sup 2}) are also discussed. We point out the current issues and expected optimum accuracy in 2006 and the future.

  4. Absolute calibration of ultraviolet filter photometry

    NASA Technical Reports Server (NTRS)

    Bless, R. C.; Fairchild, T.; Code, A. D.

    1972-01-01

    The essential features of the calibration procedure can be divided into three parts. First, the shape of the bandpass of each photometer was determined by measuring the transmissions of the individual optical components and also by measuring the response of the photometer as a whole. Secondly, each photometer was placed in the essentially-collimated synchrotron radiation bundle maintained at a constant intensity level, and the output signal was determined from about 100 points on the objective. Finally, two or three points on the objective were illuminated by synchrotron radiation at several different intensity levels covering the dynamic range of the photometers. The output signals were placed on an absolute basis by the electron counting technique described earlier.

  5. Automated acoustic intensity measurements and the effect of gear tooth profile on noise

    NASA Technical Reports Server (NTRS)

    Atherton, W. J.; Pintz, A.; Lewicki, D. G.

    1987-01-01

    Acoustic intensity measurements were made at NASA Lewis Research Center on a spur gear test apparatus. The measurements were obtained with the Robotic Acoustic Intensity Measurement System developed by Cleveland State University. This system provided dense spatial positioning, and was calibrated against a high quality acoustic intensity system. The measured gear noise compared gearsets having two different tooth profiles. The tests evaluated the sound field of the different gears for two speeds and three loads. The experimental results showed that gear tooth profile had a major effect on measured noise. Load and speed were found to have an effect on noise also.

  6. Quantitative Measurement of Integrated Band Intensities of Isoprene and Formaldehyde

    NASA Astrophysics Data System (ADS)

    Brauer, Carolyn S.; Johnson, Timothy J.; Blake, Thomas A.; Sams, Robert L.

    2013-06-01

    The OH-initiated oxidation of isoprene, which is one of the primary volatile organic compounds produced by vegetation, is a major source of atmospheric formaldehyde and other oxygenated organics. Both molecules are also known products of biomass burning. Absorption coefficients and integrated band intensities for isoprene and formaldehyde are reported in the 600 - 6500 cm^{-1} region. The pressure broadened (1 atmosphere N_2) spectra were recorded at 278, 298 and 323 K in a 19.96 cm path length cell at 0.112 cm^{-1} resolution, using a Bruker 66V FTIR. Composite spectra are composed of a minimum of seven pressures at each temperature for both molecules. These data are part of the PNNL Spectral Database, which contains quantitative spectra of over 600 molecules. These quantitative spectra facilitate atmospheric monitoring for both remote and in situ sensing and such applications will be discussed. Timothy J. Johnson, Luisa T. M. Profeta, Robert L. Sams, David W. T. Griffith, Robert L. Yokelson Vibrational Spectroscopy {53}(1);97-102 (2010).

  7. Measurement of proton and anti-proton intensities in the Tevatron Collider

    SciTech Connect

    Stephen Pordes et al.

    2003-06-04

    This paper describes the techniques used to measure the intensities of the proton (p) and anti-proton ({bar p}) beams in the Tevatron collider. The systems provide simultaneous measurements of the intensity of the 36 proton and 36 antiproton bunches and their longitudinal profiles.

  8. Absolute Measurements of Macrophage Migration Inhibitory Factor and Interleukin-1-β mRNA Levels Accurately Predict Treatment Response in Depressed Patients

    PubMed Central

    Ferrari, Clarissa; Uher, Rudolf; Bocchio-Chiavetto, Luisella; Riva, Marco Andrea; Pariante, Carmine M.

    2016-01-01

    Background: Increased levels of inflammation have been associated with a poorer response to antidepressants in several clinical samples, but these findings have had been limited by low reproducibility of biomarker assays across laboratories, difficulty in predicting response probability on an individual basis, and unclear molecular mechanisms. Methods: Here we measured absolute mRNA values (a reliable quantitation of number of molecules) of Macrophage Migration Inhibitory Factor and interleukin-1β in a previously published sample from a randomized controlled trial comparing escitalopram vs nortriptyline (GENDEP) as well as in an independent, naturalistic replication sample. We then used linear discriminant analysis to calculate mRNA values cutoffs that best discriminated between responders and nonresponders after 12 weeks of antidepressants. As Macrophage Migration Inhibitory Factor and interleukin-1β might be involved in different pathways, we constructed a protein-protein interaction network by the Search Tool for the Retrieval of Interacting Genes/Proteins. Results: We identified cutoff values for the absolute mRNA measures that accurately predicted response probability on an individual basis, with positive predictive values and specificity for nonresponders of 100% in both samples (negative predictive value=82% to 85%, sensitivity=52% to 61%). Using network analysis, we identified different clusters of targets for these 2 cytokines, with Macrophage Migration Inhibitory Factor interacting predominantly with pathways involved in neurogenesis, neuroplasticity, and cell proliferation, and interleukin-1β interacting predominantly with pathways involved in the inflammasome complex, oxidative stress, and neurodegeneration. Conclusion: We believe that these data provide a clinically suitable approach to the personalization of antidepressant therapy: patients who have absolute mRNA values above the suggested cutoffs could be directed toward earlier access to more

  9. Tone-burst technique measures high-intensity sound absorption

    NASA Technical Reports Server (NTRS)

    Powell, J. G.; Van Houten, J. J.

    1971-01-01

    Tone-burst technique, in which narrow-bandwidth, short-duration sonic pulse is propagated down a standing-wave tube, measures sound absorbing capacity of materials used in jet engine noise abatement. Technique eliminates effects of tube losses and yields normal-incidence absorption coefficient of specimen.

  10. Measurement of absolute transition frequencies of {sup 87}Rb to nS and nD Rydberg states by means of electromagnetically induced transparency

    SciTech Connect

    Mack, Markus; Karlewski, Florian; Hattermann, Helge; Hoeckh, Simone; Jessen, Florian; Cano, Daniel; Fortagh, Jozsef

    2011-05-15

    We report the measurement of absolute excitation frequencies of {sup 87}Rb to nS and nD Rydberg states. The Rydberg transition frequencies are obtained by observing electromagnetically induced transparency on a rubidium vapor cell. The accuracy of the measurement of each state is < or approx. 1 MHz, which is achieved by frequency stabilizing the two diode lasers employed for the spectroscopy to a frequency comb and a frequency comb calibrated wavelength meter, respectively. Based on the spectroscopic data we determine the quantum defects of {sup 87}Rb, and compare it with previous measurements on {sup 85}Rb. We determine the ionization frequency from the 5S{sub 1/2}(F=1) ground state of {sup 87}Rb to 1010.029 164 6(3)THz, providing the binding energy of the ground state with an accuracy improved by two orders of magnitude.

  11. Diffraction pattern intensity measurements in the introductory college physics laboratory using microcomputers

    NASA Astrophysics Data System (ADS)

    Soundranayagam, R.; Ramayya, A. V.; Cleeman, L.; Riecken, Mark; Fuson, Nelson; Springer, John

    1983-10-01

    Measurement of the intensity variations in a single slit diffraction pattern formed by a laser beam is made by means of a photoresistor detector interfaced with an Apple II-plus microcomputer through the paddle (game controller) connection. The computer programs, written in BASIC and assembly language, enable the student to (1) determine quantitatively the intensity of the maxima and minima; (2) see the intensity pattern as the data is acquired; (3) obtain a hard copy of the intensity plot observed on the screen monitor; and (4) compare the experimental and theoretical intensity patterns.

  12. Picosecond-TALIF and VUV absorption measurements of absolute atomic nitrogen densities from an RF atmospheric pressure plasma jet with He/O2/N2 gas mixtures

    NASA Astrophysics Data System (ADS)

    West, Andrew; Niemi, Kari; Schröter, Sandra; Bredin, Jerome; Gans, Timo; Wagenaars, Erik

    2015-09-01

    Reactive Oxygen and Nitrogen species (RONS) from RF atmospheric pressure plasma jets (APPJs) are important in biomedical applications as well as industrial plasma processing such as surface modification. Atomic oxygen has been well studied, whereas, despite its importance in the plasma chemistry, atomic nitrogen has been somewhat neglected due to its difficulty of measurement. We present absolute densities of atomic nitrogen in APPJs operating with He/O2/N2 gas mixtures in open air, using picosecond Two-photon Absorption Laser Induced Fluorescence (ps-TALIF) and vacuum ultra-violet (VUV) absorption spectroscopy. In order to apply the TALIF technique in complex, He/O2/N2 mixtures, we needed to directly measure the collisional quenching effects using picosecond pulse widths (32ps). Traditional calculated quenching corrections, used in nanosecond TALIF, are inadequate due to a lack of quenching data for complex mixtures. Absolute values for the densities were found by calibrating against a known density of Krypton. The VUV absorption experiments were conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Atomic nitrogen densities were on the order of 1020 m-3 with good agreement between TALIF and VUV absorption. UK EPSRC grant EP/K018388/1.

  13. Measurement of the B-->pi l nu branching fraction and determination of absolute value of V(ub) with tagged B mesons.

    PubMed

    Aubert, B; Barate, R; Bona, M; Boutigny, D; Couderc, F; Karyotakis, Y; Lees, J P; Poireau, V; Tisserand, V; Zghiche, A; Grauges, E; Palano, A; Chen, J C; Qi, N D; Rong, G; Wang, P; Zhu, Y S; Eigen, G; Ofte, I; Stugu, B; Abrams, G S; Battaglia, M; Brown, D N; Button-Shafer, J; Cahn, R N; Charles, E; Gill, M S; Groysman, Y; Jacobsen, R G; Kadyk, J A; Kerth, L T; Kolomensky, Yu G; Kukartsev, G; Lynch, G; Mir, L M; Orimoto, T J; Pripstein, M; Roe, N A; Ronan, M T; Wenzel, W A; del Amo Sanchez, P; Barrett, M; Ford, K E; Harrison, T J; Hart, A J; Hawkes, C M; Morgan, S E; Watson, A T; Held, T; Koch, H; Lewandowski, B; Pelizaeus, M; Peters, K; Schroeder, T; Steinke, M; Boyd, J T; Burke, J P; Cottingham, W N; Walker, D; Cuhadar-Donszelmann, T; Fulsom, B G; Hearty, C; Knecht, N S; Mattison, T S; McKenna, J A; Khan, A; Kyberd, P; Saleem, M; Sherwood, D J; Teodorescu, L; Blinov, V E; Bukin, A D; Druzhinin, V P; Golubev, V B; Onuchin, A P; Serednyakov, S I; Skovpen, Yu I; Solodov, E P; Todyshev, K Yu; Best, D S; Bondioli, M; Bruinsma, M; Chao, M; Curry, S; Eschrich, I; Kirkby, D; Lankford, A J; Lund, P; Mandelkern, M; Mommsen, R K; Roethel, W; Stoker, D P; Abachi, S; Buchanan, C; Foulkes, S D; Gary, J W; Long, O; Shen, B C; Wang, K; Zhang, L; Hadavand, H K; Hill, E J; Paar, H P; Rahatlou, S; Sharma, V; Berryhill, J W; Campagnari, C; Cunha, A; Dahmes, B; Hong, T M; Kovalskyi, D; Richman, J D; Beck, T W; Eisner, A M; Flacco, C J; Heusch, C A; Kroseberg, J; Lockman, W S; Nesom, G; Schalk, T; Schumm, B A; Seiden, A; Spradlin, P; Williams, D C; Wilson, M G; Albert, J; Chen, E; Dvoretskii, A; Fang, F; Hitlin, D G; Narsky, I; Piatenko, T; Porter, F C; Ryd, A; Samuel, A; Mancinelli, G; Meadows, B T; Mishra, K; Sokoloff, M D; Blanc, F; Bloom, P C; Chen, S; Ford, W T; Hirschauer, J F; Kreisel, A; Nagel, M; Nauenberg, U; Olivas, A; Ruddick, W O; Smith, J G; Ulmer, K A; Wagner, S R; Zhang, J; Chen, A; Eckhart, E A; Soffer, A; Toki, W H; Wilson, R J; Winklmeier, F; Zeng, Q; Altenburg, D D; Feltresi, E; Hauke, A; Jasper, H; Petzold, A; Spaan, B; Brandt, T; Klose, V; Lacker, H M; Mader, W F; Nogowski, R; Schubert, J; Schubert, K R; Schwierz, R; Sundermann, J E; Volk, A; Bernard, D; Bonneaud, G R; Grenier, P; Latour, E; Thiebaux, Ch; Verderi, M; Clark, P J; Gradl, W; Muheim, F; Playfer, S; Robertson, A I; Xie, Y; Andreotti, M; Bettoni, D; Bozzi, C; Calabrese, R; Cibinetto, G; Luppi, E; Negrini, M; Petrella, A; Piemontese, L; Prencipe, E; Anulli, F; Baldini-Ferroli, R; Calcaterra, A; de Sangro, R; Finocchiaro, G; Pacetti, S; Patteri, P; Peruzzi, I M; Piccolo, M; Rama, M; Zallo, A; Buzzo, A; Capra, R; Contri, R; Lo Vetere, M; Macri, M M; Monge, M R; Passaggio, S; Patrignani, C; Robutti, E; Santroni, A; Tosi, S; Brandenburg, G; Chaisanguanthum, K S; Morii, M; Wu, J; Dubitzky, R S; Marks, J; Schenk, S; Uwer, U; Bard, D J; Bhimji, W; Bowerman, D A; Dauncey, P D; Egede, U; Flack, R L; Nash, J A; Nikolich, M B; Panduro Vazquez, W; Behera, P K; Chai, X; Charles, M J; Mallik, U; Meyer, N T; Ziegler, V; Cochran, J; Crawley, H B; Dong, L; Eyges, V; Meyer, W T; Prell, S; Rosenberg, E I; Rubin, A E; Gritsan, A V; Denig, A G; Fritsch, M; Schott, G; Arnaud, N; Davier, M; Grosdidier, G; Höcker, A; Le Diberder, F; Lepeltier, V; Lutz, A M; Oyanguren, A; Pruvot, S; Rodier, S; Roudeau, P; Schune, M H; Stocchi, A; Wang, W F; Wormser, G; Cheng, C H; Lange, D J; Wright, D M; Chavez, C A; Forster, I J; Fry, J R; Gabathuler, E; Gamet, R; George, K A; Hutchcroft, D E; Payne, D J; Schofield, K C; Touramanis, C; Bevan, A J; Di Lodovico, F; Menges, W; Sacco, R; Cowan, G; Flaecher, H U; Hopkins, D A; Jackson, P S; McMahon, T R; Ricciardi, S; Salvatore, F; Wren, A C; Brown, D N; Davis, C L; Allison, J; Barlow, N R; Barlow, R J; Chia, Y M; Edgar, C L; Lafferty, G D; Naisbit, M T; Williams, J C; Yi, J I; Chen, C; Hulsbergen, W D; Jawahery, A; Lae, C K; Roberts, D A; Simi, G; Blaylock, G; Dallapiccola, C; Hertzbach, S S; Li, X; Moore, T B; Saremi, S; Staengle, H; Cowan, R; Sciolla, G; Sekula, S J; Spitznagel, M; Taylor, F; Yamamoto, R K; Kim, H; McLachlin, S E; Patel, P M; Robertson, S H; Lazzaro, A; Lombardo, V; Palombo, F; Bauer, J M; Cremaldi, L; Eschenburg, V; Godang, R; Kroeger, R; Sanders, D A; Summers, D J; Zhao, H W; Brunet, S; Côté, D; Simard, M; Taras, P; Viaud, F B; Nicholson, H; Cavallo, N; De Nardo, G; Fabozzi, F; Gatto, C; Lista, L; Monorchio, D; Paolucci, P; Piccolo, D; Sciacca, C; Baak, M; Raven, G; Snoek, H L; Jessop, C P; Losecco, J M; Allmendinger, T; Benelli, G; Gan, K K; Honscheid, K; Hufnagel, D; Jackson, P D; Kagan, H; Kass, R; Rahimi, A M; Ter-Antonyan, R; Wong, Q K; Blount, N L; Brau, J; Frey, R; Igonkina, O; Lu, M; Rahmat, R; Sinev, N B; Strom, D; Strube, J; Torrence, E; Gaz, A; Margoni, M; Morandin, M; Pompili, A; Posocco, M; Rotondo, M; Simonetto, F; Stroili, R; Voci, C; Benayoun, M; Chauveau, J; Briand, H; David, P; Del Buono, L; de la Vaissière, Ch; Hamon, O; Hartfiel, B L; John, M J J; Leruste, Ph; Malclès, J; Ocariz, J; Roos, L; Therin, G; Gladney, L; Panetta, J; Biasini, M; Covarelli, R; Angelini, C; Batignani, G; Bettarini, S; Bucci, F; Calderini, G; Carpinelli, M; Cenci, R; Forti, F; Giorgi, M A; Lusiani, A; Marchiori, G; Mazur, M A; Morganti, M; Neri, N; Paoloni, E; Rizzo, G; Walsh, J J; Haire, M; Judd, D; Wagoner, D E; Biesiada, J; Danielson, N; Elmer, P; Lau, Y P; Lu, C; Olsen, J; Smith, A J S; Telnov, A V; Bellini, F; Cavoto, G; D'Orazio, A; del Re, D; Di Marco, E; Faccini, R; Ferrarotto, F; Ferroni, F; Gaspero, M; Li Gioi, L; Mazzoni, M A; Morganti, S; Piredda, G; Polci, F; Safai Tehrani, F; Voena, C; Ebert, M; Schröder, H; Waldi, R; Adye, T; De Groot, N; Franek, B; Olaiya, E O; Wilson, F F; Aleksan, R; Emery, S; Gaidot, A; Ganzhur, S F; Hamel de Monchenault, G; Kozanecki, W; Legendre, M; Vasseur, G; Yèche, Ch; Zito, M; Chen, X R; Liu, H; Park, W; Purohit, M V; Wilson, J R; Allen, M T; Aston, D; Bartoldus, R; Bechtle, P; Berger, N; Claus, R; Coleman, J P; Convery, M R; Cristinziani, M; Dingfelder, J C; Dorfan, J; Dubois-Felsmann, G P; Dujmic, D; Dunwoodie, W; Field, R C; Glanzman, T; Gowdy, S J; Graham, M T; Halyo, V; Hast, C; Hryn'ova, T; Innes, W R; Kelsey, M H; Kim, P; Leith, D W G S; Li, S; Luitz, S; Luth, V; Lynch, H L; MacFarlane, D B; Marsiske, H; Messner, R; Muller, D R; O'Grady, C P; Ozcan, V E; Perazzo, A; Perl, M; Pulliam, T; Ratcliff, B N; Roodman, A; Salnikov, A A; Schindler, R H; Schwiening, J; Snyder, A; Stelzer, J; Su, D; Sullivan, M K; Suzuki, K; Swain, S K; Thompson, J M; Va'vra, J; van Bakel, N; Weaver, M; Weinstein, A J R; Wisniewski, W J; Wittgen, M; Wright, D H; Yarritu, A K; Yi, K; Young, C C; Burchat, P R; Edwards, A J; Majewski, S A; Petersen, B A; Roat, C; Wilden, L; Ahmed, S; Alam, M S; Bula, R; Ernst, J A; Jain, V; Pan, B; Saeed, M A; Wappler, F R; Zain, S B; Bugg, W; Krishnamurthy, M; Spanier, S M; Eckmann, R; Ritchie, J L; Satpathy, A; Schilling, C J; Schwitters, R F; Izen, J M; Lou, X C; Ye, S; Bianchi, F; Gallo, F; Gamba, D; Bomben, M; Bosisio, L; Cartaro, C; Cossutti, F; Della Ricca, G; Dittongo, S; Lanceri, L; Vitale, L; Azzolini, V; Martinez-Vidal, F; Banerjee, Sw; Bhuyan, B; Brown, C M; Fortin, D; Hamano, K; Kowalewski, R; Nugent, I M; Roney, J M; Sobie, R J; Back, J J; Harrison, P F; Latham, T E; Mohanty, G B; Pappagallo, M; Band, H R; Chen, X; Cheng, B; Dasu, S; Datta, M; Flood, K T; Hollar, J J; Kutter, P E; Mellado, B; Mihalyi, A; Pan, Y; Pierini, M; Prepost, R; Wu, S L; Yu, Z; Neal, H

    2006-11-24

    We report a measurement of the B-->pi l nu branching fraction based on 211 fb(-1) of data collected with the BABAR detector. We use samples of B0 and B+ mesons tagged by a second B meson reconstructed in a semileptonic or hadronic decay and combine the results assuming isospin symmetry to obtain B(B(0)-->pi- l+ nu) = (1.33+/-0.17stat+/-0.11syst) x 10(-4). We determine the magnitude of the Cabibbo-Kobayashi-Maskawa matrix element absolute value V(ub) by combining the partial branching fractions measured in ranges of the momentum transfer squared and theoretical calculations of the form factor. Using a recent lattice QCD calculation, we find absolute value V(ub) = (4.5+/-0.5stat+/-0.3syst(+0.7) -0.5FF x 10(-3), where the last error is due to the normalization of the form factor. PMID:17155736

  14. Some aspects of sound discomfort caused by streetcar traffic. [noise intensity measurements and health aspects

    NASA Technical Reports Server (NTRS)

    Ursoniu, C.; Puca, N.; Dankner, A.; Moise, G.; Sirbu, A.

    1974-01-01

    Streetcar noise was investigated on different lines and inside different types by sonometer measurements. The results showed variations of the total noise intensity between 88-97 db. In some squares with heavy traffic the total noise intensity reached 106 db. Noise intensity measurements inside different types of streetcars brought to light high values between 101-106 db, while in the case of the new silent type of streetcar the values were 86-87 db. The importance of the sound discomfort produced by streetcar traffic is emphasized, inasmuch as the noise intensity exceeds by far the values recommended by communal hygiene.

  15. Two-photon LIF on the HIT-SI3 experiment: Absolute density and temperature measurements of deuterium neutrals

    NASA Astrophysics Data System (ADS)

    Elliott, Drew; Sutherland, Derek; Siddiqui, Umair; Scime, Earl; Everson, Chris; Morgan, Kyle; Hossack, Aaron; Nelson, Brian; Jarboe, Tom

    2016-11-01

    Two-photon laser-induced fluorescence measurements were performed on the helicity injected torus (HIT-SI3) device to determine the density and temperature of the background neutral deuterium population. Measurements were taken in 2 ms long pulsed plasmas after the inductive helicity injectors were turned off. Attempts to measure neutrals during the main phase of the plasma were unsuccessful, likely due to the density of neutrals being below the detection threshold of the diagnostic. An unexpectedly low density of atomic deuterium was measured in the afterglow; roughly 100 times lower than the theoretical prediction of 1017 m-3. The neutral temperatures measured were on the order of 1 eV. Temporally and spatially resolved neutral density and temperature data are presented.

  16. Measuring malaria endemicity from intense to interrupted transmission

    PubMed Central

    Hay, Simon I; Smith, David L; Snow, Robert W

    2008-01-01

    Summary The quantification of malaria transmission for the classification of malaria risk has long been a concern for epidemiologists. During the era of the Global Malaria Eradication Programme, measurements of malaria endemicity were institutionalised by their incorporation into rules outlining defined action points for malaria control programmes. We review the historical development of these indices and their contemporary relevance. This is at a time when many malaria-endemic countries are scaling-up their malaria control activities and reconsidering their prospects for elimination. These considerations are also important to an international community that has recently been challenged to revaluate the prospects for malaria eradication. PMID:18387849

  17. Eosinophil count - absolute

    MedlinePlus

    Eosinophils; Absolute eosinophil count ... the white blood cell count to give the absolute eosinophil count. ... than 500 cells per microliter (cells/mcL). Normal value ranges may vary slightly among different laboratories. Talk ...

  18. Quantum assignments and intensity measures for methane between 1100 and 1800 per cm - A comparison between theory and experiment. [in outer planets atmospheres

    NASA Technical Reports Server (NTRS)

    Lutz, B. L.; Pierre, C.; Pierre, G.; Champion, J. P.

    1982-01-01

    The paper analyzes line positions and absolute line strengths of Blatherwick et al. (1979), based on moderately high resolution spectra of methane between 1100 and 1800 per cm, obtained using the Fourier transform spectrometer and the multiple-pass cold cell at the NASA Ames Research Center. Hamiltonian models are used to calculate theoretical relative line strengths, which, in combination with measured line strengths, yield integrated band strengths for the fundamentals v2 and v4. Ratios of calculated intensities to experimental intensities are analyzed, and the systematic deviations in the P- and R-branches of the v2 band are found to be represented by a Herman-Wallis type factor for Coriolis interactions. An analysis of ratios of calculated to experimental intensities of the v4 band yields a small correction to the Herman-Wallis factor.

  19. Absolute measurement of anti. nu. /sub p/ for /sup 252/Cf using the ORNL large liquid scintillator neutron detector

    SciTech Connect

    Spencer, R.R.; Gwin, R.; Ingle, R.

    1981-08-01

    The ORNL large liquid scintillator detector was used in a precise determination of anti ..nu../sub p/, the number of neutrons emitted promptly, for spontaneous fission of /sup 252/Cf. Measurements of the detector efficiency over a broad energy region were made by means of a proton-recoil technique employing the ORELA white neutron source. Monte Carlo calculation of the detector efficiency for a spectrum representative of /sup 252/Cf fission neutrons was calibrated with these elaborate measurements. The unusually flat response of the neutron detector resulted in elimination of several known sources of error. Experimental measurement was coupled with calculational methods to correct for other known errors. These measurements lead to an unusually small estimated uncertainty of 0.2% in the value obtained, anti ..nu../sub p/ = 3.773 +- 0.007.

  20. Absolute atomic oxygen and nitrogen densities in radio-frequency driven atmospheric pressure cold plasmas: Synchrotron vacuum ultra-violet high-resolution Fourier-transform absorption measurements

    SciTech Connect

    Niemi, K.; O'Connell, D.; Gans, T.; Oliveira, N. de; Joyeux, D.; Nahon, L.; Booth, J. P.

    2013-07-15

    Reactive atomic species play a key role in emerging cold atmospheric pressure plasma applications, in particular, in plasma medicine. Absolute densities of atomic oxygen and atomic nitrogen were measured in a radio-frequency driven non-equilibrium plasma operated at atmospheric pressure using vacuum ultra-violet (VUV) absorption spectroscopy. The experiment was conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Measurements were carried out in plasmas operated in helium with air-like N{sub 2}/O{sub 2} (4:1) admixtures. A maximum in the O-atom concentration of (9.1 {+-} 0.7) Multiplication-Sign 10{sup 20} m{sup -3} was found at admixtures of 0.35 vol. %, while the N-atom concentration exhibits a maximum of (5.7 {+-} 0.4) Multiplication-Sign 10{sup 19} m{sup -3} at 0.1 vol. %.

  1. Absolute dose measurements by means of a small cylindrical ionization chamber for very high dose per pulse high energy electron beams

    SciTech Connect

    Karaj, E.; Righi, S.; Di Martino, F.

    2007-03-15

    Very high dose per pulse (3-13 cGy/pulse) high energy electron beams are currently produced by special linear accelerators (linac) dedicated to Intra Operative Radiation Therapy (IORT). The electron beams produced by such linacs are collimated by special Perspex applicators of various size and cylindrically shaped. The biggest problems from the dosimetric point of view are caused by the high dose-per-pulse values and the use of inclined applicators. In this work measurements of absolute dose for the inclined applicators were done by using a small cylindrical ionization chamber, type CC01 (Wellhofer), a parallel plane ionization chamber type Markus (PTW 23343) and radiochromic films type EBT. We show a method which allows calculating the quality correction factors for CC01 chamber with an uncertainty of 1% and the absolute dose value for the inclined applicators using CC01 with an uncertainty of 3.1% for electron beams of energy of 6 and 7 MeV produced by the linac dedicated to IORT Novac7.

  2. Intensity-Value Corrections for Integrating Sphere Measurements of Solid Samples Measured Behind Glass

    SciTech Connect

    Johnson, Timothy J.; Bernacki, Bruce E.; Redding, Rebecca L.; Su, Yin-Fong; Brauer, Carolyn S.; Myers, Tanya L.; Stephan, Eric G.

    2014-11-01

    Accurate and calibrated directional-hemispherical reflectance spectra of solids are important for both in situ and remote sensing. Many solids are in the form of powders or granules and to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass for the ultraviolet (UV), visible, or near-infrared spectral regions. Using both experimental methods and a simple optical model, we demonstrate that glass (fused quartz in our case) leads to artifacts in the reflectance values. We report our observations that the measured reflectance values, for both hemispherical and diffuse reflectance, are distorted by the additional reflections arising at the air–quartz and sample–quartz interfaces. The values are dependent on the sample reflectance and are offset in intensity in the hemispherical case, leading to measured values up to ~6% too high for a 2% reflectance surface, ~3.8% too high for 10% reflecting surfaces, approximately correct for 40–60% diffuse-reflecting surfaces, and ~1.5% too low for 99% reflecting Spectralon® surfaces. For the case of diffuse-only reflectance, the measured values are uniformly too low due to the polished glass, with differences of nearly 6% for a 99% reflecting matte surface. The deviations arise from the added reflections from the quartz surfaces, as verified by both theory and experiment, and depend on sphere design. Finally, empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300–2300 nm range.

  3. Absolute optical frequency measurements of the cesium D1 transitions and their effect on alpha, the fine-structured constant

    NASA Astrophysics Data System (ADS)

    Calkins, Keith Gordon

    The fine-structure constant or electromagnetic coupling constant, alpha e, is a dimensionless ratio which unites many physics subfields. Although known precisely via experiments in each subfield, there is disagreement within and between subfields. In particular, precise values obtained via electron ge - 2 experiments which depend heavily on QED calculations have not always been in agreement with those obtained via muon g mu - 2 experiments. Also, solid state measurements (quantum hall effect and AC Josephson effect) often disagree with neutronic hmn measurements. alphae is often said to vary with energy but the question remains as to whether or not its low energy value is stable now or has been stable over the history of the universe. Improved precision helps resolve these issues as they relate to physics, possibly beyond the standard model. The Optical Frequency Measurements group in the Time and Frequency Division at the National Institute of Science and Technology (NIST, Boulder, CO) developed and maintains a femtosecond laser frequency comb which is calibrated with respect to the cesium fountain clock implementation of the second. A single frequency component of the femtosecond laser comb is used together with a solid state diode laser and cesium thermal beam to precisely measure the cesium D1 F ∈ {3,4} transition frequencies. The value of fD1centroid = 335 116 048 748.1(2.4) kHz obtained for the transition centroid is over fifteen times more precise than the most recent previous measurement. A precise value for the cesium D1 hyperfine splitting fHFe = 1 167 723.6(4.7) kHz is reported as well. This value is also over fifteen times more precise than the most recent previous measurement. These new neutral 133Cs 6s 2 S½ → 6p 2 P½ transition (D1) frequencies, when combined with the 2002 CODATA values of the Rydberg, proton/electron mass ratio, cesium atomic mass, and cesium recoil frequency, provide an almost QED-free value of alpha: alphae = 1/137.036 0000

  4. Activity measurements and determination of gamma-ray emission intensities in the decay of 65Zn.

    PubMed

    Bé, Marie-Martine

    2006-01-01

    An International EUROMET exercise, Action 721, was organized with the objective of obtaining more reliable decay data on the disintegration of 65Zn. Nine laboratories participated, sending their results relating to activity measurements and 1115-keV gamma-ray emission intensity. Participants mainly used the 4pibeta-gamma coincidence method for the activity measurement, the resulting values and uncertainty budgets are described. New gamma-ray emission intensities were also measured in this exercise and, taking into account previously published values, the intensity of the 1115-keV gamma-ray emission has been determined to be 50.22(11)%.

  5. Self-Report Measures of Hand Pain Intensity: Current Evidence and Recommendations.

    PubMed

    Castarlenas, Elena; de la Vega, Rocío; Jensen, Mark P; Miró, Jordi

    2016-02-01

    Successful management of problems related to the hands and upper extremities begins with a comprehensive assessment of the pain experience and related factors. Pain intensity is the domain most commonly assessed, and pain relief is often the primary goal of treatment. Because pain is a private and subjective experience, self-report is considered the gold standard of pain measurement. This article describes and discusses the strengths and weaknesses of the most commonly used self-report scales used to measure hand pain intensity, and gives recommendations to help clinicians select from among the various options for measuring the intensity of hand pain.

  6. Measurement procedure for absolute broadband infrared up-conversion photoluminescent quantum yields: Correcting for absorption/re-emission

    SciTech Connect

    MacDougall, Sean K. W.; Ivaturi, Aruna; Marques-Hueso, Jose; Richards, Bryce S.

    2014-06-15

    The internal photoluminescent quantum yield (iPLQY) – defined as the ratio of emitted photons to those absorbed – is an important parameter in the evaluation and application of luminescent materials. The iPLQY is rarely reported due to the complexities in the calibration of such a measurement. Herein, an experimental method is proposed to correct for re-emission, which leads to an underestimation of the absorption under broadband excitation. Although traditionally the iPLQY is measured using monochromatic sources for linear materials, this advancement is necessary for nonlinear materials with wavelength dependent iPLQY, such as the application of up-conversion to solar energy harvesting. The method requires an additional measurement of the emission line shape that overlaps with the excitation and absorption spectra. Through scaling of the emission spectrum, at the long wavelength edge where an overlap of excitation does not occur, it is possible to better estimate the value of iPLQY. The method has been evaluated for a range of nonlinear material concentrations and under various irradiances to analyze the necessity and boundary conditions that favor the proposed method. Use of this refined method is important for a reliable measurement of iPLQY under a broad illumination source such as the Sun.

  7. Characterization of an Indirect-Detection Amorphous Silicon Detector for Dosimetric Measurement of Intensity Modulated Photon Fields

    NASA Astrophysics Data System (ADS)

    Bailey, Daniel Wayne

    Indirect-detection amorphous silicon electronic imagers show much promise for measurement of radiation dose, particularly for pre-treatment verification of patient-specific intensity modulated radiotherapy plans. These instruments, commonly known as Electronic Portal Imaging Devices (EPIDs), have high data density, large detecting area, convenient electronic read-out, excellent positional reproducibility, and are quickly becoming standard equipment on today's medical megavoltage linear accelerators. However, because these devices were originally intended to be digital radiograph imagers and not dosimeters, the modeling, calibration, and prediction of their response to dose carries a number of challenges. For instance, EPID dose images exhibit off-axis dose errors of up to 18% with increasing distance from the central axis of the imager (as compared to dose predictions calculated by a commercially available treatment planning system). Furthermore, these off-axis errors are asymmetric, with higher errors in the in-plane direction than in the cross-plane direction. In this work, methods are proposed to account for EPID off-axis effects by precisely calculating off-axis output factors from experimental measurements to increase the accuracy of EPID absolute dose measurement. Using these methods, dose readings acquired over the entire surface of the detector agree to within 2% accuracy as compared to respective EPID dose predictions. Similarly, the percentage of measured dose points that agree with respective calculated dose points (using 3%, 3 mm criteria) improves by as much as 60% for off-axis intensity modulated photon fields. Furthermore, a number of clinical applications of EPID dosimetry are investigated, including pixel response constancy, the effect of data density on a common metric for quantitatively comparing measured vs. calculated dose, and the implementation of an electronic portal dosimetry program for radiotherapy quality assurance.

  8. Near-absolute Hugoniot measurements in aluminum to 500 GPa using a magnetically accelerated flyer plate technique

    NASA Astrophysics Data System (ADS)

    Knudson, M. D.; Lemke, R. W.; Hayes, D. B.; Hall, C. A.; Deeney, C.; Asay, J. R.

    2003-10-01

    Hugoniot measurements were performed on aluminum (6061-T6) in the stress range of 100-500 GPa (1-5 Mbar) using a magnetically accelerated flyer plate technique. This method of flyer plate launch utilizes the high currents, and resulting magnetic fields produced at the Sandia Z Accelerator to accelerate macroscopic aluminum flyer plates (approximately 12×25 mm in lateral dimension and ˜300 μm in thickness) to velocities in excess of 20 km/s. This technique was used to perform plate-impact shock-wave experiments on aluminum to determine the high-stress equation of state (EOS). Using a near-symmetric impact method, Hugoniot measurements were obtained in the stress range of 100-500 GPa. The results of these experiments are in excellent agreement with previously reported Hugoniot measurements of aluminum in this stress range. The agreement at lower stress, where highly accurate gas gun data exist, establishes the magnetically accelerated flyer plate technique as a suitable method for generating EOS data. Furthermore, the present results exhibit increased accuracy over the previous techniques used to obtain data in the higher-stress range. This improved accuracy enhances our understanding of the response of aluminum to 500 GPa, and lends increased confidence to the use of aluminum as a standard material in future impedance matching experiments.

  9. Spectral Properties of THz Quantum-Cascade Lasers: Frequency Noise, Phase-Locking and Absolute Frequency Measurement

    NASA Astrophysics Data System (ADS)

    Ravaro, Marco; Jagtap, Vishal; Manquest, Christophe; Gellie, Pierre; Santarelli, Giorgio; Sirtori, Carlo; Khanna, Suraj P.; Linfield, Edmund H.; Barbieri, Stefano

    2013-06-01

    Quantum cascade lasers combine desirable features, namely high optical power and compactness, as no other coherent source in the field of THz generation. While their maximum operating temperature is progressively increasing, getting close to the range accessible by Peltier cooling, their range of application is expanding into new fields, such us molecular spectroscopy and their use as local oscillators. These applications would benefit from the investigation and improvement of the laser coherence properties. In this contribution we report the exploitation of electro-optic coherent detection based on a near-IR frequency comb to measure the frequency noise of a free running 2.5 THz quantum cascade laser. An intrinsic linewidth quantum limit of ~230 Hz has been measured, in good agreement with the Schawlow-Townes theoretical prediction. The same detection scheme is then exploited to phase-lock the quantum cascade laser line to a multiple of the comb tooth spacing, while a second comb allows to precisely measure the THz frequency. Such a dual frequency comb experimental setup thus yields a narrow line THz emission traceable to a microwave frequency standard.

  10. New experimental methodology, setup and LabView program for accurate absolute thermoelectric power and electrical resistivity measurements between 25 and 1600 K: Application to pure copper, platinum, tungsten, and nickel at very high temperatures

    SciTech Connect

    Abadlia, L.; Mayoufi, M.; Gasser, F.; Khalouk, K.; Gasser, J. G.

    2014-09-15

    In this paper we describe an experimental setup designed to measure simultaneously and very accurately the resistivity and the absolute thermoelectric power, also called absolute thermopower or absolute Seebeck coefficient, of solid and liquid conductors/semiconductors over a wide range of temperatures (room temperature to 1600 K in present work). A careful analysis of the existing experimental data allowed us to extend the absolute thermoelectric power scale of platinum to the range 0-1800 K with two new polynomial expressions. The experimental device is controlled by a LabView program. A detailed description of the accurate dynamic measurement methodology is given in this paper. We measure the absolute thermoelectric power and the electrical resistivity and deduce with a good accuracy the thermal conductivity using the relations between the three electronic transport coefficients, going beyond the classical Wiedemann-Franz law. We use this experimental setup and methodology to give new very accurate results for pure copper, platinum, and nickel especially at very high temperatures. But resistivity and absolute thermopower measurement can be more than an objective in itself. Resistivity characterizes the bulk of a material while absolute thermoelectric power characterizes the material at the point where the electrical contact is established with a couple of metallic elements (forming a thermocouple). In a forthcoming paper we will show that the measurement of resistivity and absolute thermoelectric power characterizes advantageously the (change of) phase, probably as well as DSC (if not better), since the change of phases can be easily followed during several hours/days at constant temperature.

  11. New experimental methodology, setup and LabView program for accurate absolute thermoelectric power and electrical resistivity measurements between 25 and 1600 K: application to pure copper, platinum, tungsten, and nickel at very high temperatures.

    PubMed

    Abadlia, L; Gasser, F; Khalouk, K; Mayoufi, M; Gasser, J G

    2014-09-01

    In this paper we describe an experimental setup designed to measure simultaneously and very accurately the resistivity and the absolute thermoelectric power, also called absolute thermopower or absolute Seebeck coefficient, of solid and liquid conductors/semiconductors over a wide range of temperatures (room temperature to 1600 K in present work). A careful analysis of the existing experimental data allowed us to extend the absolute thermoelectric power scale of platinum to the range 0-1800 K with two new polynomial expressions. The experimental device is controlled by a LabView program. A detailed description of the accurate dynamic measurement methodology is given in this paper. We measure the absolute thermoelectric power and the electrical resistivity and deduce with a good accuracy the thermal conductivity using the relations between the three electronic transport coefficients, going beyond the classical Wiedemann-Franz law. We use this experimental setup and methodology to give new very accurate results for pure copper, platinum, and nickel especially at very high temperatures. But resistivity and absolute thermopower measurement can be more than an objective in itself. Resistivity characterizes the bulk of a material while absolute thermoelectric power characterizes the material at the point where the electrical contact is established with a couple of metallic elements (forming a thermocouple). In a forthcoming paper we will show that the measurement of resistivity and absolute thermoelectric power characterizes advantageously the (change of) phase, probably as well as DSC (if not better), since the change of phases can be easily followed during several hours/days at constant temperature.

  12. Index of Distinctness--A Measure of the Intensity of Cognitive Preferences.

    ERIC Educational Resources Information Center

    van den Berg, Euwe; And Others

    1982-01-01

    Two statistical indices of distinctness (intensity) were developed to measure patterns of cognitive preference scores. Results indicated a variety of cognitive preferences, and the distinctness variable was shown to be a useful tool in cognitive preference research. (CJ)

  13. Time-dependent intensity and phase measurements of ultrashort laser pulses as short as 10 fs

    SciTech Connect

    DeLong, K.W.; Fittinghoff, D.N.; Ladera, C.L.; Trebino, R.; Taft, G.; Rundquist, A.; Murnane, M.M.; Kapteyn, H.C.; Christov, I.P.

    1995-05-01

    Frequency-Resolved Optical Gating (FROG) measures the time-dependent intensity and phase of an ultrashort laser pulse. Using FROG, we have tested theories for the operation of sub{minus}10 fs laser oscillators.

  14. Sub-micron absolute distance measurements in sub-millisecond times with dual free-running femtosecond Er fiber-lasers.

    PubMed

    Liu, Tze-An; Newbury, Nathan R; Coddington, Ian

    2011-09-12

    We demonstrate a simplified dual-comb LIDAR setup for precision absolute ranging that can achieve a ranging precision of 2 μm in 140 μs acquisition time. With averaging, the precision drops below 1 μm at 0.8 ms and below 200 nm at 20 ms. The system can measure the distance to multiple targets with negligible dead zones and a ranging ambiguity of 1 meter. The system is much simpler than a previous coherent dual-comb LIDAR because the two combs are replaced by free-running, saturable-absorber-based femtosecond Er fiber lasers, rather than tightly phase-locked combs, with the entire time base provided by a single 10-digit frequency counter. Despite the simpler design, the system provides a factor of three improved performance over the previous coherent dual comb LIDAR system.

  15. Development of a vector-tensor system to measure the absolute magnetic flux density and its gradient in magnetically shielded rooms

    SciTech Connect

    Voigt, J.; Knappe-Grüneberg, S.; Gutkelch, D.; Neuber, S.; Schnabel, A.; Burghoff, M.; Haueisen, J.

    2015-05-15

    Several experiments in fundamental physics demand an environment of very low, homogeneous, and stable magnetic fields. For the magnetic characterization of such environments, we present a portable SQUID system that measures the absolute magnetic flux density vector and the gradient tensor. This vector-tensor system contains 13 integrated low-critical temperature (LTc) superconducting quantum interference devices (SQUIDs) inside a small cylindrical liquid helium Dewar with a height of 31 cm and 37 cm in diameter. The achievable resolution depends on the flux density of the field under investigation and its temporal drift. Inside a seven-layer mu-metal shield, an accuracy better than ±23 pT for the components of the static magnetic field vector and ±2 pT/cm for each of the nine components of the gradient tensor is reached by using the shifting method.

  16. Development of a vector-tensor system to measure the absolute magnetic flux density and its gradient in magnetically shielded rooms.

    PubMed

    Voigt, J; Knappe-Grüneberg, S; Gutkelch, D; Haueisen, J; Neuber, S; Schnabel, A; Burghoff, M

    2015-05-01

    Several experiments in fundamental physics demand an environment of very low, homogeneous, and stable magnetic fields. For the magnetic characterization of such environments, we present a portable SQUID system that measures the absolute magnetic flux density vector and the gradient tensor. This vector-tensor system contains 13 integrated low-critical temperature (LTc) superconducting quantum interference devices (SQUIDs) inside a small cylindrical liquid helium Dewar with a height of 31 cm and 37 cm in diameter. The achievable resolution depends on the flux density of the field under investigation and its temporal drift. Inside a seven-layer mu-metal shield, an accuracy better than ±23 pT for the components of the static magnetic field vector and ±2 pT/cm for each of the nine components of the gradient tensor is reached by using the shifting method.

  17. Sub-micron absolute distance measurements in sub-millisecond times with dual free-running femtosecond Er fiber-lasers.

    PubMed

    Liu, Tze-An; Newbury, Nathan R; Coddington, Ian

    2011-09-12

    We demonstrate a simplified dual-comb LIDAR setup for precision absolute ranging that can achieve a ranging precision of 2 μm in 140 μs acquisition time. With averaging, the precision drops below 1 μm at 0.8 ms and below 200 nm at 20 ms. The system can measure the distance to multiple targets with negligible dead zones and a ranging ambiguity of 1 meter. The system is much simpler than a previous coherent dual-comb LIDAR because the two combs are replaced by free-running, saturable-absorber-based femtosecond Er fiber lasers, rather than tightly phase-locked combs, with the entire time base provided by a single 10-digit frequency counter. Despite the simpler design, the system provides a factor of three improved performance over the previous coherent dual comb LIDAR system. PMID:21935219

  18. Calibration of diffuse correlation spectroscopy with a time-resolved near-infrared technique to yield absolute cerebral blood flow measurements

    PubMed Central

    Diop, Mamadou; Verdecchia, Kyle; Lee, Ting-Yim; St Lawrence, Keith

    2011-01-01

    A primary focus of neurointensive care is the prevention of secondary brain injury, mainly caused by ischemia. A noninvasive bedside technique for continuous monitoring of cerebral blood flow (CBF) could improve patient management by detecting ischemia before brain injury occurs. A promising technique for this purpose is diffuse correlation spectroscopy (DCS) since it can continuously monitor relative perfusion changes in deep tissue. In this study, DCS was combined with a time-resolved near-infrared technique (TR-NIR) that can directly measure CBF using indocyanine green as a flow tracer. With this combination, the TR-NIR technique can be used to convert DCS data into absolute CBF measurements. The agreement between the two techniques was assessed by concurrent measurements of CBF changes in piglets. A strong correlation between CBF changes measured by TR-NIR and changes in the scaled diffusion coefficient measured by DCS was observed (R2 = 0.93) with a slope of 1.05 ± 0.06 and an intercept of 6.4 ± 4.3% (mean ± standard error). PMID:21750781

  19. CO{sub 2} laser light scattering by bare soils for emissivity measurements: Absolute calibration and correlation with backscattering and composition

    SciTech Connect

    Kologo, N.; Stoll, M.P.

    1996-07-01

    Measurements of the scattering cross section of a number of bare soils have been made with CO{sub 2} laser illumination at 10.59 {micro}m. The primary focus was on absolute calibration of the measurements. First, comparison of emissivity values resulting from the application of Kirchhoff`s relation after angular integration of the bidirectional measurements, with emissivity values obtained from the analysis of the emitted radiation show excellent agreement to within less than 0.3%. Second, it was found that a simple formula holds for a relationship between the emissivity and co- and cross-polarized backscattering cross section at an angle of 30{degree}. Third, a clear correlation was observed between emissivity and composition (in this case % Al + Fe oxides; % SiO{sub 2}) for a homogeneous series of samples from the same area in Niger. These results emphasize the importance of calibrated experimental data. The implications of the research give evidence of the advantage of obtaining emissivity from remote reflectivity measurements and possibly only backscattering measurements, and remotely estimating mineral composition.

  20. Determination of critical assembly absolute power using post-irradiation activation measurement of week-lived fission products.

    PubMed

    Košťál, Michal; Švadlenková, Marie; Milčák, Ján; Rypar, Vojtěch; Koleška, Michal

    2014-07-01

    The work presents a detailed comparison of calculated and experimentally determined net peak areas of longer-living fission products after 100 h irradiation on a reactor with power of ~630 W and several days cooling. Specifically the nuclides studied are (140)Ba, (103)Ru, (131)I, (141)Ce, (95)Zr. The good agreement between the calculated and measured net peak areas, which is better than in determination using short lived (92)Sr, is reported. The experiment was conducted on the VVER-1000 mock-up installed on the LR-0 reactor. The Monte Carlo approach has been used for calculations. The influence of different data libraries on results of calculation is discussed as well.

  1. Absolute OH concentration profiles measurements in high pressure counterflow flames by coupling LIF, PLIF, and absorption techniques

    NASA Astrophysics Data System (ADS)

    Matynia, A.; Idir, M.; Molet, J.; Roche, C.; de Persis, S.; Pillier, L.

    2012-08-01

    A high-pressure combustion chamber enclosing counterflow burners was set-up at ICARE-CNRS laboratory. It allows the stabilization of flat twin premixed flames at atmospheric and high pressure. In this study, lean and stoichiometric methane/air counterflow premixed flames were studied at various pressures (0.1 MPa to 0.7 MPa). Relative OH concentration profiles were measured by Laser Induced Fluorescence. Great care was attached to the determination of the fluorescence signal by taking into account the line broadening and deexcitation by quenching which both arise at high pressure. Subsequently, OH profiles were calibrated in concentration by laser absorption technique associated with planar laser induced fluorescence. Results are successfully compared with literature. The good quality of the results attests of the experimental set-up ability to allow the study of flame structure at high pressure.

  2. Measurement of the absolute branching fractions B→Dπ, D*π, D**π with a missing mass method

    NASA Astrophysics Data System (ADS)

    Aubert, B.; Bona, M.; Boutigny, D.; Couderc, F.; Karyotakis, Y.; Lees, J. P.; Poireau, V.; Tisserand, V.; Zghiche, A.; Grauges, E.; Palano, A.; Chen, J. C.; Qi, N. D.; Rong, G.; Wang, P.; Zhu, Y. S.; Eigen, G.; Ofte, I.; Stugu, B.; Abrams, G. S.; Battaglia, M.; Brown, D. N.; Button-Shafer, J.; Cahn, R. N.; Charles, E.; Gill, M. S.; Groysman, Y.; Jacobsen, R. G.; Kadyk, J. A.; Kerth, L. T.; Kolomensky, Yu. G.; Kukartsev, G.; Lynch, G.; Mir, L. M.; Orimoto, T. J.; Pripstein, M.; Roe, N. A.; Ronan, M. T.; Wenzel, W. A.; Sanchez, P. Del Amo; Barrett, M.; Ford, K. E.; Harrison, T. J.; Hart, A. J.; Hawkes, C. M.; Watson, A. T.; Held, T.; Koch, H.; Lewandowski, B.; Pelizaeus, M.; Peters, K.; Schroeder, T.; Steinke, M.; Boyd, J. T.; Burke, J. P.; Cottingham, W. N.; Walker, D.; Asgeirsson, D. J.; Cuhadar-Donszelmann, T.; Fulsom, B. G.; Hearty, C.; Knecht, N. S.; Mattison, T. S.; McKenna, J. A.; Khan, A.; Kyberd, P.; Saleem, M.; Sherwood, D. J.; Teodorescu, L.; Blinov, V. E.; Bukin, A. D.; Druzhinin, V. P.; Golubev, V. B.; Onuchin, A. P.; Serednyakov, S. I.; Skovpen, Yu. I.; Solodov, E. P.; Todyshev, K. Yu; Bondioli, M.; Bruinsma, M.; Chao, M.; Curry, S.; Eschrich, I.; Kirkby, D.; Lankford, A. J.; Lund, P.; Mandelkern, M.; Mommsen, R. K.; Roethel, W.; Stoker, D. P.; Abachi, S.; Buchanan, C.; Foulkes, S. D.; Gary, J. W.; Long, O.; Shen, B. C.; Wang, K.; Zhang, L.; Hadavand, H. K.; Hill, E. J.; Paar, H. P.; Rahatlou, S.; Sharma, V.; Berryhill, J. W.; Campagnari, C.; Cunha, A.; Dahmes, B.; Hong, T. M.; Kovalskyi, D.; Richman, J. D.; Beck, T. W.; Eisner, A. M.; Flacco, C. J.; Heusch, C. A.; Kroseberg, J.; Lockman, W. S.; Nesom, G.; Schalk, T.; Schumm, B. A.; Seiden, A.; Spradlin, P.; Williams, D. C.; Wilson, M. G.; Albert, J.; Chen, E.; Dvoretskii, A.; Fang, F.; Hitlin, D. G.; Narsky, I.; Piatenko, T.; Porter, F. C.; Ryd, A.; Mancinelli, G.; Meadows, B. T.; Mishra, K.; Sokoloff, M. D.; Blanc, F.; Bloom, P. C.; Chen, S.; Ford, W. T.; Hirschauer, J. F.; Kreisel, A.; Nagel, M.; Nauenberg, U.; Olivas, A.; Ruddick, W. O.; Smith, J. G.; Ulmer, K. A.; Wagner, S. R.; Zhang, J.; Chen, A.; Eckhart, E. A.; Soffer, A.; Toki, W. H.; Wilson, R. J.; Winklmeier, F.; Zeng, Q.; Altenburg, D. D.; Feltresi, E.; Hauke, A.; Jasper, H.; Merkel, J.; Petzold, A.; Spaan, B.; Brandt, T.; Klose, V.; Lacker, H. M.; Mader, W. F.; Nogowski, R.; Schubert, J.; Schubert, K. R.; Schwierz, R.; Sundermann, J. E.; Volk, A.; Bernard, D.; Bonneaud, G. R.; Latour, E.; Thiebaux, Ch.; Verderi, M.; Clark, P. J.; Gradl, W.; Muheim, F.; Playfer, S.; Robertson, A. I.; Xie, Y.; Andreotti, M.; Bettoni, D.; Bozzi, C.; Calabrese, R.; Cibinetto, G.; Luppi, E.; Negrini, M.; Petrella, A.; Piemontese, L.; Prencipe, E.; Anulli, F.; Baldini-Ferroli, R.; Calcaterra, A.; de Sangro, R.; Finocchiaro, G.; Pacetti, S.; Patteri, P.; Peruzzi, I. M.; Piccolo, M.; Rama, M.; Zallo, A.; Buzzo, A.; Contri, R.; Vetere, M. Lo; Macri, M. M.; Monge, M. R.; Passaggio, S.; Patrignani, C.; Robutti, E.; Santroni, A.; Tosi, S.; Brandenburg, G.; Chaisanguanthum, K. S.; Morii, M.; Wu, J.; Dubitzky, R. S.; Marks, J.; Schenk, S.; Uwer, U.; Bard, D. J.; Bhimji, W.; Bowerman, D. A.; Dauncey, P. D.; Egede, U.; Flack, R. L.; Nash, J. A.; Nikolich, M. B.; Vazquez, W. Panduro; Behera, P. K.; Chai, X.; Charles, M. J.; Mallik, U.; Meyer, N. T.; Ziegler, V.; Cochran, J.; Crawley, H. B.; Dong, L.; Eyges, V.; Meyer, W. T.; Prell, S.; Rosenberg, E. I.; Rubin, A. E.; Gritsan, A. V.; Denig, A. G.; Fritsch, M.; Schott, G.; Arnaud, N.; Davier, M.; Grosdidier, G.; Höcker, A.; Diberder, F. Le; Lepeltier, V.; Lutz, A. M.; Oyanguren, A.; Pruvot, S.; Rodier, S.; Roudeau, P.; Schune, M. H.; Stocchi, A.; Wang, W. F.; Wormser, G.; Cheng, C. H.; Lange, D. J.; Wright, D. M.; Chavez, C. A.; Forster, I. J.; Fry, J. R.; Gabathuler, E.; Gamet, R.; George, K. A.; Hutchcroft, D. E.; Payne, D. J.; Schofield, K. C.; Touramanis, C.; Bevan, A. J.; Lodovico, F. Di; Menges, W.; Sacco, R.; Cowan, G.; Flaecher, H. U.; Hopkins, D. A.; Jackson, P. S.; McMahon, T. R.; Ricciardi, S.; Salvatore, F.; Wren, A. C.; Brown, D. N.; Davis, C. L.; Allison, J.; Barlow, N. R.; Barlow, R. J.; Chia, Y. M.; Edgar, C. L.; Lafferty, G. D.; Naisbit, M. T.; Williams, J. C.; Yi, J. I.; Chen, C.; Hulsbergen, W. D.; Jawahery, A.; Lae, C. K.; Roberts, D. A.; Simi, G.; Blaylock, G.; Dallapiccola, C.; Hertzbach, S. S.; Li, X.; Moore, T. B.; Saremi, S.; Staengle, H.; Cowan, R.; Sciolla, G.; Sekula, S. J.; Spitznagel, M.; Taylor, F.; Yamamoto, R. K.; Kim, H.; McLachlin, S. E.; Patel, P. M.; Robertson, S. H.; Lazzaro, A.; Lombardo, V.; Palombo, F.; Bauer, J. M.; Cremaldi, L.; Eschenburg, V.; Godang, R.; Kroeger, R.; Sanders, D. A.; Summers, D. J.; Zhao, H. W.; Brunet, S.; Côté, D.; Simard, M.; Taras, P.; Viaud, F. B.; Nicholson, H.; Cavallo, N.; Nardo, G. De; Fabozzi, F.; Gatto, C.; Lista, L.; Monorchio, D.; Paolucci, P.; Piccolo, D.; Sciacca, C.; Baak, M. A.; Raven, G.; Snoek, H. L.; Jessop, C. P.; Losecco, J. M.; Allmendinger, T.; Benelli, G.; Corwin, L. A.; Gan, K. K.; Honscheid, K.; Hufnagel, D.; Jackson, P. D.; Kagan, H.; Kass, R.; Rahimi, A. M.; Regensburger, J. J.; Ter-Antonyan, R.; Wong, Q. K.; Blount, N. L.; Brau, J.; Frey, R.; Igonkina, O.; Kolb, J. A.; Lu, M.; Rahmat, R.; Sinev, N. B.; Strom, D.; Strube, J.; Torrence, E.; Gaz, A.; Margoni, M.; Morandin, M.; Pompili, A.; Posocco, M.; Rotondo, M.; Simonetto, F.; Stroili, R.; Voci, C.; Benayoun, M.; Briand, H.; Chauveau, J.; David, P.; Buono, L. Del; de La Vaissière, Ch.; Hamon, O.; Hartfiel, B. L.; Leruste, Ph.; Malclès, J.; Ocariz, J.; Roos, L.; Therin, G.; Gladney, L.; Biasini, M.; Covarelli, R.; Angelini, C.; Batignani, G.; Bettarini, S.; Bucci, F.; Calderini, G.; Carpinelli, M.; Cenci, R.; Forti, F.; Giorgi, M. A.; Lusiani, A.; Marchiori, G.; Mazur, M. A.; Morganti, M.; Neri, N.; Paoloni, E.; Rizzo, G.; Walsh, J. J.; Haire, M.; Judd, D.; Wagoner, D. E.; Biesiada, J.; Danielson, N.; Elmer, P.; Lau, Y. P.; Lu, C.; Olsen, J.; Smith, A. J. S.; Telnov, A. V.; Bellini, F.; Cavoto, G.; D'Orazio, A.; Del Re, D.; Marco, E. Di; Faccini, R.; Ferrarotto, F.; Ferroni, F.; Gaspero, M.; Gioi, L. Li; Mazzoni, M. A.; Morganti, S.; Piredda, G.; Polci, F.; Tehrani, F. Safai; Voena, C.; Ebert, M.; Schröder, H.; Waldi, R.; Adye, T.; Groot, N. De; Franek, B.; Olaiya, E. O.; Wilson, F. F.; Aleksan, R.; Emery, S.; Gaidot, A.; Ganzhur, S. F.; de Monchenault, G. Hamel; Kozanecki, W.; Legendre, M.; Vasseur, G.; Yèche, Ch.; Zito, M.; Chen, X. R.; Liu, H.; Park, W.; Purohit, M. V.; Wilson, J. R.; Allen, M. T.; Aston, D.; Bartoldus, R.; Bechtle, P.; Berger, N.; Claus, R.; Coleman, J. P.; Convery, M. R.; Cristinziani, M.; Dingfelder, J. C.; Dorfan, J.; Dubois-Felsmann, G. P.; Dujmic, D.; Dunwoodie, W.; Field, R. C.; Glanzman, T.; Gowdy, S. J.; Graham, M. T.; Grenier, P.; Halyo, V.; Hast, C.; Hryn'Ova, T.; Innes, W. R.; Kelsey, M. H.; Kim, P.; Leith, D. W. G. S.; Li, S.; Luitz, S.; Luth, V.; Lynch, H. L.; Macfarlane, D. B.; Marsiske, H.; Messner, R.; Muller, D. R.; O'Grady, C. P.; Ozcan, V. E.; Perazzo, A.; Perl, M.; Pulliam, T.; Ratcliff, B. N.; Roodman, A.; Salnikov, A. A.; Schindler, R. H.; Schwiening, J.; Snyder, A.; Stelzer, J.; Su, D.; Sullivan, M. K.; Suzuki, K.; Swain, S. K.; Thompson, J. M.; Va'Vra, J.; van Bakel, N.; Weaver, M.; Weinstein, A. J. R.; Wisniewski, W. J.; Wittgen, M.; Wright, D. H.; Yarritu, A. K.; Yi, K.; Young, C. C.; Burchat, P. R.; Edwards, A. J.; Majewski, S. A.; Petersen, B. A.; Roat, C.; Wilden, L.; Ahmed, S.; Alam, M. S.; Bula, R.; Ernst, J. A.; Jain, V.; Pan, B.; Saeed, M. A.; Wappler, F. R.; Zain, S. B.; Bugg, W.; Krishnamurthy, M.; Spanier, S. M.; Eckmann, R.; Ritchie, J. L.; Satpathy, A.; Schilling, C. J.; Schwitters, R. F.; Izen, J. M.; Lou, X. C.; Ye, S.; Bianchi, F.; Gallo, F.; Gamba, D.; Bomben, M.; Bosisio, L.; Cartaro, C.; Cossutti, F.; Ricca, G. Della; Dittongo, S.; Lanceri, L.; Vitale, L.; Azzolini, V.; Lopez-March, N.; Martinez-Vidal, F.; Banerjee, Sw.; Bhuyan, B.; Brown, C. M.; Fortin, D.; Hamano, K.; Kowalewski, R.; Nugent, I. M.; Roney, J. M.; Sobie, R. J.; Back, J. J.; Harrison, P. F.; Latham, T. E.; Mohanty, G. B.; Pappagallo, M.; Band, H. R.; Chen, X.; Cheng, B.; Dasu, S.; Datta, M.; Flood, K. T.; Hollar, J. J.; Kutter, P. E.; Mellado, B.; Mihalyi, A.; Pan, Y.; Pierini, M.; Prepost, R.; Wu, S. L.; Yu, Z.; Neal, H.

    2006-12-01

    We present branching fraction measurements of charged and neutral B decays to Dπ-, D*π-, and “D**”π- with a missing mass method, based on a sample of 231×106 Υ(4S)→BB¯ pairs collected by the BABAR detector at the PEP-II e+e- collider. One of the B mesons is fully reconstructed and the other one decays to a reconstructed charged π and a companion charmed meson identified by its recoil mass, inferred by kinematics. Here “D**” refers to the sum of all the nonstrange charm meson states with masses in the range 2.2 2.8GeV/c2. We measure the branching fractions: B(B-→D0π-)=(4.49±0.21±0.23)×10-3, B(B-→D*0π-)=(5.13±0.22±0.28)×10-3, B(B-→“D**0”π-)=(5.50±0.52±1.04)×10-3, B(B¯0→D+π-)=(3.03±0.23±0.23)×10-3, B(B¯0→D*+π-)=(2.99±0.23±0.24)×10-3, B(B¯0→“D**+”π-)=(2.34±0.65±0.88)×10-3, and their ratios.

  3. Development and metrological characterization of a tunable diode laser absorption spectroscopy (TDLAS) spectrometer for simultaneous absolute measurement of carbon dioxide and water vapor.

    PubMed

    Pogány, Andrea; Wagner, Steven; Werhahn, Olav; Ebert, Volker

    2015-01-01

    Simultaneous detection of two analytes, carbon dioxide (CO2) and water vapor (H2O), has been realized using tunable diode laser absorption spectroscopy (TDLAS) with a single distributed feedback diode laser at 2.7 μm. The dynamic range of the spectrometer is extended from the low parts per million to the percentage range using two gas cells, a single-pass cell with 0.77 m, and a Herriott-type multipass cell with 76 m path length. Absolute measurements were carried out, i.e., amount fractions of the analytes were calculated based on previously determined spectral line parameters, without the need for an instrument calibration using gas standards. A thorough metrological characterization of the spectrometer is presented. We discuss traceability of all parameters used for amount fraction determination and provide a comprehensive uncertainty assessment. Relative expanded uncertainties (k = 2, 95% confidence level) of the measured amount fractions are shown to be in the 2-3% range for both analytes. Minimum detectable amount fractions are 0.16 μmol/mol for CO2 and 1.1 μmol/mol for H2O for 76 m path length and 5 s averaging time. This corresponds to normalized detection limits of 27 μmol/mol m Hz(-1/2) for CO2 and 221 μmol/mol m Hz(-1/2) for H2O. Precision of the spectrometer, determined using Allan variance analysis, is 3.3 nmol/mol for CO2 and 21 nmol/mol for H2O. The spectrometer has been validated using reference gas mixtures with known CO2 and H2O amount fractions. An application example of the absolute TDLAS spectrometer as a reference instrument to validate other sensors is also presented.

  4. Using Mean Absolute Relative Phase, Deviation Phase and Point-Estimation Relative Phase to Measure Postural Coordination in a Serial Reaching Task.

    PubMed

    Galgon, Anne K; Shewokis, Patricia A

    2016-03-01

    The objectives of this communication are to present the methods used to calculate mean absolute relative phase (MARP), deviation phase (DP) and point estimate relative phase (PRP) and compare their utility in measuring postural coordination during the performance of a serial reaching task. MARP and DP are derived from continuous relative phase time series representing the relationship between two body segments or joints during movements. MARP is a single measure used to quantify the coordination pattern and DP measures the stability of the coordination pattern. PRP also quantifies coordination patterns by measuring the relationship between the timing of maximal or minimal angular displacements of two segments within cycles of movement. Seven young adults practiced a bilateral serial reaching task 300 times over 3 days. Relative phase measures were used to evaluate inter-joint relationships for shoulder-hip (proximal) and hip-ankle (distal) postural coordination at early and late learning. MARP, PRP and DP distinguished between proximal and distal postural coordination. There was no effect of practice on any of the relative phase measures for the group, but individual differences were seen over practice. Combined, MARP and DP estimated stability of in-phase and anti-phase postural coordination patterns, however additional qualitative movement analyses may be needed to interpret findings in a serial task. We discuss the strengths and limitations of using MARP and DP and compare MARP and DP to PRP measures in assessing coordination patterns in the context of various types of skillful tasks. Key pointsMARP, DP and PRP measures coordination between segments or joint anglesAdvantages and disadvantages of each measure should be considered in relationship to the performance taskMARP and DP may capture coordination patterns and stability of the patterns during discrete tasks or phases of movements within a taskPRP and SD or PRP may capture coordination patterns and

  5. Interferometric measurement of surface shape by wavelength tuning suppressing random intensity error.

    PubMed

    Kim, Yangjin; Hibino, Kenichi; Sugita, Naohiko; Mitsuishi, Mamoru

    2016-08-10

    In this research, the susceptibility of the phase-shifting algorithms to the random intensity error is formulated and estimated. The susceptibility of the random intensity error of conventional windowed phase-shifting algorithms is discussed, and the 7N-6 phase-shifting algorithm is developed to minimize the random intensity error using the characteristic polynomial theory. Finally, the surface shape of the transparent wedge plate is measured using a wavelength-tuning Fizeau interferometer and the 7N-6 algorithm. The experimental results indicate that the surface shape measurement accuracy for the transparent plate is 2.5 nm.

  6. Transverse beam shape measurements of intense proton beams using optical transition radiation

    SciTech Connect

    Scarpine, Victor E.; /Fermilab

    2012-03-01

    A number of particle physics experiments are being proposed as part of the Department of Energy HEP Intensity Frontier. Many of these experiments will utilize megawatt level proton beams onto targets to form secondary beams of muons, kaons and neutrinos. These experiments require transverse size measurements of the incident proton beam onto target for each beam spill. Because of the high power levels, most beam intercepting profiling techniques will not work at full beam intensity. The possibility of utilizing optical transition radiation (OTR) for high intensity proton beam profiling is discussed. In addition, previous measurements of OTR beam profiles from the NuMI beamline are presented.

  7. Interferometric measurement of surface shape by wavelength tuning suppressing random intensity error.

    PubMed

    Kim, Yangjin; Hibino, Kenichi; Sugita, Naohiko; Mitsuishi, Mamoru

    2016-08-10

    In this research, the susceptibility of the phase-shifting algorithms to the random intensity error is formulated and estimated. The susceptibility of the random intensity error of conventional windowed phase-shifting algorithms is discussed, and the 7N-6 phase-shifting algorithm is developed to minimize the random intensity error using the characteristic polynomial theory. Finally, the surface shape of the transparent wedge plate is measured using a wavelength-tuning Fizeau interferometer and the 7N-6 algorithm. The experimental results indicate that the surface shape measurement accuracy for the transparent plate is 2.5 nm. PMID:27534496

  8. Hydroxyl-radical-induced degradative oxidation of beta-lactam antibiotics in water: absolute rate constant measurements.

    PubMed

    Dail, Michelle K; Mezyk, Stephen P

    2010-08-19

    The beta-lactam antibiotics are some of the most prevalent pharmaceutical contaminants currently being detected in aquatic environments. Because the presence of any trace level of antibiotic in water may adversely affect aquatic ecosystems and contribute to the production of antibiotic-resistant bacteria, active removal by additional water treatments, such as using advanced oxidation and reduction processes (AO/RPs), may be required. However, to ensure that any AOP treatment process occurs efficiently and quantitatively, a full understanding of the kinetics and mechanisms of all of the chemical reactions involved under the conditions of use is necessary. In this study, we report on our kinetic measurements for the hydroxyl-radical-induced oxidation of 11 beta-lactam antibiotics obtained using electron pulse radiolysis techniques. For the 5-member ring species, an average reaction rate constant of (7.9 +/- 0.8) x 10(9) M(-1) s(-1) was obtained, slightly faster than for the analogous 6-member ring containing antibiotics, (6.6 +/- 1.2) x 10(9) M(-1) s(-1). The consistency of these rate constants for each group infers a common reaction mechanism, consisting of the partitioning of the hydroxyl radical between addition to peripheral aromatic rings and reaction with the central double-ring core of these antibiotics.

  9. Design, performance, and calculated error of a Faraday cup for absolute beam current measurements of 600-MeV protons

    NASA Technical Reports Server (NTRS)

    Beck, S. M.

    1975-01-01

    A mobile self-contained Faraday cup system for beam current measurments of nominal 600 MeV protons was designed, constructed, and used at the NASA Space Radiation Effects Laboratory. The cup is of reentrant design with a length of 106.7 cm and an outside diameter of 20.32 cm. The inner diameter is 15.24 cm and the base thickness is 30.48 cm. The primary absorber is commercially available lead hermetically sealed in a 0.32-cm-thick copper jacket. Several possible systematic errors in using the cup are evaluated. The largest source of error arises from high-energy electrons which are ejected from the entrance window and enter the cup. A total systematic error of -0.83 percent is calculated to be the decrease from the true current value. From data obtained in calibrating helium-filled ion chambers with the Faraday cup, the mean energy required to produce one ion pair in helium is found to be 30.76 + or - 0.95 eV for nominal 600 MeV protons. This value agrees well, within experimental error, with reported values of 29.9 eV and 30.2 eV.

  10. Measuring the absolute disintegration rate of a radioactive gas with a moveable endplate discharge counter (MEP) and theoretical calculation of wall effect

    SciTech Connect

    Jaffey, A.H.; Gray, J.; Bentley, W.C.; Lerner, J.L.

    1987-09-01

    A precision built moveable endplate Geiger-Mueller counter was used to measure the absolute disintegration rate of a beta-emitting radioactive gas. A Geiger-Mueller counter used for measuring gaseous radioactivity has <100% counting efficiency owing to two factors: (1) ''end effect,'' due to decreased and distorted fields at the ends where wire-insulator joints are placed, and (2) ''wall effect,'' due to non-ionization by beta particles emitted near to and heading into the wall. The end effect was evaluated by making one end of the counter movable and measuring counting rates at a number of endplate positions. Much of the wall effect was calculated theoretically, based on known data for primary ionization of electrons as a function of energy and gas composition. Corrections were then made for the ''shakeoff'' effect in beta decay and for backscattering of electrons from the counter wall. Measurements and calculations were made for a sample of /sup 85/Kr (beta energy, 0.67 MeV). The wall effect calculation is readily extendable to other beta energies.

  11. Association between absolute volumes of lung spared from low-dose irradiation and radiation-induced lung injury after intensity-modulated radiotherapy in lung cancer: a retrospective analysis

    PubMed Central

    Chen, Jinmei; Hong, Jinsheng; Zou, Xi; Lv, Wenlong; Guo, Feibao; Hong, Hualan; Zhang, Weijian

    2015-01-01

    The aim of this study was to investigate the association between absolute volumes of lung spared from low-dose irradiation and radiation-induced lung injury (RILI) after intensity-modulated radiotherapy (IMRT) for lung cancer. The normal lung relative volumes receiving greater than 5, 10, 20 and 30 Gy (V5–30) mean lung dose (MLD), and absolute volumes spared from greater than 5, 10, 20 and 30 Gy (AVS5–30) for the bilateral and ipsilateral lungs of 83 patients were recorded. Any association of clinical factors and dose–volume parameters with Grade ≥2 RILI was analyzed. The median follow-up was 12.3 months; 18 (21.7%) cases of Grade 2 RILI, seven (8.4%) of Grade 3 and two (2.4%) of Grade 4 were observed. Univariate analysis revealed the located lobe of the primary tumor. V5, V10, V20, MLD of the ipsilateral lung, V5, V10, V20, V30 and MLD of the bilateral lung, and AVS5 and AVS10 of the ipsilateral lung were associated with Grade ≥2 RILI (P < 0.05). Multivariate analysis indicated AVS5 of the ipsilateral lung was prognostic for Grade ≥2 RILI (P = 0.010, OR = 0.272, 95% CI: 0.102–0.729). Receiver operating characteristic curves indicated Grade ≥2 RILI could be predicted using AVS5 of the ipsilateral lung (area under curve, 0.668; cutoff value, 564.9 cm3; sensitivity, 60.7%; specificity, 70.4%). The incidence of Grade ≥2 RILI was significantly lower with AVS5 of the ipsilateral lung ≥564.9 cm3 than with AVS5 < 564.9 cm3 (P = 0.008). Low-dose irradiation relative volumes and MLD of the bilateral or ipsilateral lung were associated with Grade ≥2 RILI, and AVS5 of the ipsilateral lung was prognostic for Grade ≥2 RILI for lung cancer after IMRT. PMID:26454068

  12. Frequency-domain analysis of absolute gravimeters

    NASA Astrophysics Data System (ADS)

    Svitlov, S.

    2012-12-01

    An absolute gravimeter is analysed as a linear time-invariant system in the frequency domain. Frequency responses of absolute gravimeters are derived analytically based on the propagation of the complex exponential signal through their linear measurement functions. Depending on the model of motion and the number of time-distance coordinates, an absolute gravimeter is considered as a second-order (three-level scheme) or third-order (multiple-level scheme) low-pass filter. It is shown that the behaviour of an atom absolute gravimeter in the frequency domain corresponds to that of the three-level corner-cube absolute gravimeter. Theoretical results are applied for evaluation of random and systematic measurement errors and optimization of an experiment. The developed theory agrees with known results of an absolute gravimeter analysis in the time and frequency domains and can be used for measurement uncertainty analyses, building of vibration-isolation systems and synthesis of digital filtering algorithms.

  13. Intensive sound speed monitoring in ocean and its impact on the GPS/acoustic seafloor geodetic measurement

    NASA Astrophysics Data System (ADS)

    Kido, Motoyuki

    2016-04-01

    GPS/acoustic (GPS/A) technique, based on GPS positioning and acoustic ranging, is now getting a popular tool to measure seafloor crustal movement. Several groups in the world have been intensively conducted campaign surveys in the region of scientifically interest. As the technology of measurement has been matured and plenty of data are accumulated, researchers are now aware of the limit of its precision mainly due to unexpected undulation of sound speed in ocean, which significantly degrades acoustic ranging. If sound speed structure keeps its figure during survey period, e.g., more than a couple of hours, it can be estimated by a moving survey to get sufficient paths from various directions to illustrate the structure. However the sound speed structure often varies quickly with in a hour due to internal gravitational wave excited by interaction of tidal current and seafloor topography. In this case one cannot separate temporal and spatial variations. We revisited our numerous sound speed profile data derived from numbers of XBT measurements, which were concurrently carried out with GPS/A survey along the Nankai Trough and Japan Trench. Among the measurements, we found notably short-period variation in sound speed profile through intensive XBT survey repeatedly cast every 6 minutes for one hour, which also appeared in residuals in traveltime of acoustic ranging. The same feature is also found in more moderate rate for semidiurnal undulation, in which vertical oscillation of the middle of the profile can be clearly seen rather than variation of absolute sound speed. This also reflects traveltime residuals in the GPS/A measurement. These typical frequencies represent dominant wavelengths of spatial sound speed variation. In the latter, local horizontal variation can be negligible in the vicinity of a point survey area and the traditional analysis can be applicable that assumes time-varying stratified sound speed structure. In the former case, on the contrary, local

  14. Measurement of the absolute penetration depth and surface resistance of superconductors and normal metals with the variable spacing parallel plate resonator

    NASA Astrophysics Data System (ADS)

    Talanov, Vladimir V.; Mercaldo, Lucia V.; Anlage, Steven M.; Claassen, John H.

    2000-05-01

    The variable spacing parallel plate resonator (VSPPR) is a microwave transmission line resonator with a continuously variable thickness of the dielectric spacer between the superconducting or metallic plates, filled by cryogenic liquid or vacuum. We measure the dielectric spacer thickness dependencies of the resonator frequency and quality factor, and fit them to theoretical forms, in order to extract the absolute values of penetration depth, λ, and surface resistance, Rs. A cryogenic micropositioning setup is developed to vary the spacer thickness from 0 to 100 μm with a resolution of 8.5 nm, and to maintain parallelism of the resonator plates. Measurement of ac capacitance between the plates is utilized to directly determine the separation between the resonator plates and to reduce the effect of their tilt and nonflatness on the accuracy of the measured Rs and λ. Because the operating temperature is fixed (77 K), the result for a superconductor is independent of an a priori model for the penetration depth versus temperature. This technique can also be employed as a surface impedance standard for characterization of high temperature superconducting films for microwave applications.

  15. Absolute OH density measurements in the effluent of a cold atmospheric-pressure Ar-H2O RF plasma jet in air

    NASA Astrophysics Data System (ADS)

    Verreycken, Tiny; Mensink, Rob; van der Horst, Ruud; Sadeghi, Nader; Bruggeman, Peter J.

    2013-10-01

    Absolute OH densities are obtained in a radio-frequency-driven Ar-H2O atmospheric-pressure plasma jet by laser-induced fluorescence (LIF), calibrated by Rayleigh scattering and by UV broadband absorption. The measurements are carried out in ambient air and the effect of air entrainment into the Ar jet is measured by analyzing the time-resolved fluorescence signals. The OH densities are obtained for different water vapor concentrations admixed to the Ar and as a function of the axial distance from the nozzle. A sensitivity analysis to deduce the accuracy of the model-calculated OH density from the LIF measurement is reported. It is found that the UV absorption and the LIF results correspond within experimental accuracy close to the nozzle and deviate in the far effluent. The possible reasons are discussed. The OH densities found in the plasma jet are in the range (0.1-2.5) × 1021 m-3 depending on the water concentration and plasma conditions.

  16. Absolute transition probabilities of phosphorus.

    NASA Technical Reports Server (NTRS)

    Miller, M. H.; Roig, R. A.; Bengtson, R. D.

    1971-01-01

    Use of a gas-driven shock tube to measure the absolute strengths of 21 P I lines and 126 P II lines (from 3300 to 6900 A). Accuracy for prominent, isolated neutral and ionic lines is estimated to be 28 to 40% and 18 to 30%, respectively. The data and the corresponding theoretical predictions are examined for conformity with the sum rules.-

  17. Rapid measurements of intensities for safety assessment of advanced imaging sequences

    NASA Astrophysics Data System (ADS)

    Jensen, Jørgen Arendt; Rasmussen, Morten Fischer; Stuart, Matthias Bo; Tomov, Borislav G.

    2014-03-01

    FDA requires that intensity and safety parameters are measured for all imaging schemes for clinical imaging. This is often cumbersome, since the scan sequence has to broken apart, measurements conducted for the individually emitted beams, and the final intensity levels calculated by combining the intensities from the individual beams. This paper suggests a fast measurement scheme using the multi-line sampling capability of modern scanners and research systems. The hydrophone is connected to one sampling channel in the research system, and the intensity is measured for all imaging lines in one emission sequence. This makes it possible to map out the pressure field and hence intensity level for all imaging lines in a single measurement. The approach has several advantages: the scanner does not have to be re-programmed and can use the scan sequence without modification. The measurements are orders of magnitude faster (minutes rather than hours) and the final intensity level calculation can be made generic and reused for any kind of scan sequence by just knowing the number of imaging lines and the pulse repetition time. The scheme has been implemented on the Acoustic Intensity Measurement System AIMS III (Onda, Sunnyvale, California, USA). The research scanner SARUS is used for the experiments, where one of the channels is used for the hydrophone signal. A 3 MHz BK 8820e (BK Medical, Herlev, Denmark) convex array with 192 elements is used along with an Onda HFL-0400 hydrophone connected to a AH-2010 pre-amplifier (Onda Corporation, Sunnyvale, USA). A single emission sequence is employed for testing and calibrating the approach. The measurements using the AIMS III and SARUS systems after calibration agree within a relative standard deviation of 0.24%. A duplex B-mode and flow sequence is also investigated. The complex intensity map is measured and the time averaged spatial peak intensity is found. A single point measurement takes 3.43 seconds and the whole sequence can

  18. Absolute flux scale for radioastronomy

    SciTech Connect

    Ivanov, V.P.; Stankevich, K.S.

    1986-07-01

    The authors propose and provide support for a new absolute flux scale for radio astronomy, which is not encumbered with the inadequacies of the previous scales. In constructing it the method of relative spectra was used (a powerful tool for choosing reference spectra). A review is given of previous flux scales. The authors compare the AIS scale with the scale they propose. Both scales are based on absolute measurements by the ''artificial moon'' method, and they are practically coincident in the range from 0.96 to 6 GHz. At frequencies above 6 GHz, 0.96 GHz, the AIS scale is overestimated because of incorrect extrapolation of the spectra of the primary and secondary standards. The major results which have emerged from this review of absolute scales in radio astronomy are summarized.

  19. Near-field vector intensity measurements of a small solid rocket motor.

    PubMed

    Gee, Kent L; Giraud, Jarom H; Blotter, Jonathan D; Sommerfeldt, Scott D

    2010-08-01

    Near-field vector intensity measurements have been made of a 12.7-cm diameter nozzle solid rocket motor. The measurements utilized a test rig comprised of four probes each with four low-sensitivity 6.35-mm pressure microphones in a tetrahedral arrangement. Measurements were made with the rig at nine positions (36 probe locations) within six nozzle diameters of the plume shear layer. Overall levels at these locations range from 135 to 157 dB re 20 microPa. Vector intensity maps reveal that, as frequency increases, the dominant source region contracts and moves upstream with peak directivity at greater angles from the plume axis.

  20. Absolute calibration of optical flats

    DOEpatents

    Sommargren, Gary E.

    2005-04-05

    The invention uses the phase shifting diffraction interferometer (PSDI) to provide a true point-by-point measurement of absolute flatness over the surface of optical flats. Beams exiting the fiber optics in a PSDI have perfect spherical wavefronts. The measurement beam is reflected from the optical flat and passed through an auxiliary optic to then be combined with the reference beam on a CCD. The combined beams include phase errors due to both the optic under test and the auxiliary optic. Standard phase extraction algorithms are used to calculate this combined phase error. The optical flat is then removed from the system and the measurement fiber is moved to recombine the two beams. The newly combined beams include only the phase errors due to the auxiliary optic. When the second phase measurement is subtracted from the first phase measurement, the absolute phase error of the optical flat is obtained.

  1. Prospects for clustering and lensing measurements with forthcoming intensity mapping and optical surveys

    NASA Astrophysics Data System (ADS)

    Pourtsidou, A.; Bacon, D.; Crittenden, R.; Metcalf, R. B.

    2016-06-01

    We explore the potential of using intensity mapping surveys (MeerKAT, SKA) and optical galaxy surveys (DES, LSST) to detect H I clustering and weak gravitational lensing of 21 cm emission in auto- and cross-correlation. Our forecasts show that high-precision measurements of the clustering and lensing signals can be made in the near future using the intensity mapping technique. Such studies can be used to test the intensity mapping method, and constrain parameters such as the H I density Ω _{H I}, the H I bias b_{H I} and the galaxy-H I correlation coefficient r_{H I-g}.

  2. Bragg cell laser intensity modulation: effect on laser Doppler velocimetry measurements

    SciTech Connect

    Mychkovsky, Alexander G.; Chang, Natasha A.; Ceccio, Steven L.

    2009-06-20

    In most laser Doppler velocimetry (LDV) systems, the frequency of one of the two laser beams that intersect to create the probe volume is shifted with an acousto-optic element. It is shown here that Bragg shifting can impose a problematic fluctuation in intensity on the frequency-shifted beam, producing spurious velocity measurements. This fluctuation occurs at twice the Bragg cell frequency, and its relative amplitude to the time average intensity is a function of the ratio of the laser beam diameter to the Bragg cell acoustic wavelength. A physical model and a configuration procedure to minimize adverse effects of the intensity modulations are presented.

  3. The Absolute Spectrum Polarimeter (ASP)

    NASA Technical Reports Server (NTRS)

    Kogut, A. J.

    2010-01-01

    The Absolute Spectrum Polarimeter (ASP) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from 30 GHz to 5 THz. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much greater than 1O(raised to the power of { -3}) and Compton distortion y < 10 (raised to the power of{-6}). We describe the ASP instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

  4. Absolute atomic oxygen density measurements for nanosecond-pulsed atmospheric-pressure plasma jets using two-photon absorption laser-induced fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Jiang, C.; Carter, C.

    2014-12-01

    Nanosecond-pulsed plasma jets that are generated under ambient air conditions and free from confinement of electrodes have become of great interest in recent years due to their promising applications in medicine and dentistry. Reactive oxygen species that are generated by nanosecond-pulsed, room-temperature non-equilibrium He-O2 plasma jets among others are believed to play an important role during the bactericidal or sterilization processes. We report here absolute measurements of atomic oxygen density in a 1 mm-diameter He/(1%)O2 plasma jet at atmospheric pressure using two-photon absorption laser-induced fluorescence spectroscopy. Oxygen number density on the order of 1013 cm-3 was obtained in a 150 ns, 6 kV single-pulsed plasma jet for an axial distance up to 5 mm above the device nozzle. Temporally resolved O density measurements showed that there are two maxima, separated in time by 60-70 µs, and a total pulse duration of 260-300 µs. Electrostatic modeling indicated that there are high-electric-field regions near the nozzle exit that may be responsible for the observed temporal behavior of the O production. Both the field-distribution-based estimation of the time interval for the O number density profile and a pulse-energy-dependence study confirmed that electric-field-dependent, direct and indirect electron-induced processes play important roles for O production.

  5. Commissioning and Implementation of an EPID Based IMRT QA System "Dosimetry Check" for 3D Absolute Dose Measurements and Quantitative Comparisons to MapCheck

    NASA Astrophysics Data System (ADS)

    Patel, Jalpa A.

    The software package "Dosimetry Check" by MathResolutions, LLC, provides an absolute 3D volumetric dose measurement for IMRT QA using the existing Electronic Portal Imaging Device (EPID) mounted on most linear accelerators. This package provides a feedback loop using the patient's treatment planning CT data as the phantom for dose reconstruction. The aim of this work is to study the difference between point, planar and volumetric doses with MapCheck and Dosimetry Check via the use of the EPID and the diode array respectively. Evaluating tools such as point doses at isocenter, 1-D profiles, gamma volume histograms, and dose volume histograms are used for IMRT dose comparison in three types of cases: head and neck, prostate, and lung. Dosimetry Check can be a valuable tool for IMRT QA as it uses patient specific attenuation corrections and the superiority of the EPID as compared to the MapCheck diode array. This helps reduce the uncertainty in dose for less variability in delivery and a more realistic measured vs computed dose verification system as compared to MapCheck.

  6. Quantitative measurements of one-dimensional OH absolute concentration profiles in a methane/air flat flame by bi-directional laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    Yu, Xin; Yang, Zhen; Peng, Jiang-Bo; Zhang, Lei; Ma, Yu-Fei; Yang, Chao-Bo; Li, Xiao-Hui; Sun, Rui

    2015-11-01

    The one-dimensional (1D) spatial distributions of OH absolute concentration in methane/air laminar premixed flat flame under different equivalence ratios at atmospheric pressure are investigated by using bi-directional laser-induced fluorescence (LIF) detection scheme combined with the direct absorption spectroscopy. The effective peak absorption cross section and the average temperature at a height of 2 mm above the burner are obtained by exciting absorption on the Q1(8) rotational line in the A2Σ+ (ʋ‧ = 0) ← X2Π (ʋ″ = 0) at 309.240 nm. The measured values are 1.86×10-15 cm2 and 1719 K, respectively. Spatial filtering and frequency filtering methods of reducing noise are used to deal with the experimental data, and the smoothing effects are also compared using the two methods. The spatial distribution regularities of OH concentration are obtained with the equivalence ratios ranging from 0.8 to 1.3. The spatial resolution of the measured result is 84 μm. Finally, a comparison is made between the experimental result of this paper and other relevant study results. Project supported by the National Key Scientific Instrument and Equipment Development Projects of China (Grant No. 2012YQ040164), the National Natural Science Foundation of China (Grant Nos. 61275127 and 91441130), the China Postdoctoral Science Foundation (Grant No. 2014M560262), and the Postdoctoral Fellowship in Heilongjiang Province, China (Grant No. LBH-Z14074).

  7. Intensity-Curvature Measurement Approaches for the Diagnosis of Magnetic Resonance Imaging Brain Tumors

    PubMed Central

    Ciulla, Carlo; Veljanovski, Dimitar; Rechkoska Shikoska, Ustijana; Risteski, Filip A.

    2015-01-01

    This research presents signal-image post-processing techniques called Intensity-Curvature Measurement Approaches with application to the diagnosis of human brain tumors detected through Magnetic Resonance Imaging (MRI). Post-processing of the MRI of the human brain encompasses the following model functions: (i) bivariate cubic polynomial, (ii) bivariate cubic Lagrange polynomial, (iii) monovariate sinc, and (iv) bivariate linear. The following Intensity-Curvature Measurement Approaches were used: (i) classic-curvature, (ii) signal resilient to interpolation, (iii) intensity-curvature measure and (iv) intensity-curvature functional. The results revealed that the classic-curvature, the signal resilient to interpolation and the intensity-curvature functional are able to add additional information useful to the diagnosis carried out with MRI. The contribution to the MRI diagnosis of our study are: (i) the enhanced gray level scale of the tumor mass and the well-behaved representation of the tumor provided through the signal resilient to interpolation, and (ii) the visually perceptible third dimension perpendicular to the image plane provided through the classic-curvature and the intensity-curvature functional. PMID:26644943

  8. Orientation-independent, nongeometric-mean measures of seismic intensity from two horizontal components of motion

    USGS Publications Warehouse

    Boore, David M.

    2010-01-01

    New measures of spectral intensity based on the horizontal components of ground shaking are introduced. These new measures are independent of the in situ orientation of the recordings and encompass the full range of spectral amplitudes over all possible rotation angles. Unlike previously introduced measures that are also orientation independent, no geometric means are used in the computation of the new measures. The new measures based on fiftieth percentile values of the response spectra show small but systematic increases (to a factor of about 1.07 at a 10 sec period) compared to the comparable geometric-mean measure.

  9. Simultaneous detection of rotational and translational motion in optical tweezers by measurement of backscattered intensity.

    PubMed

    Roy, Basudev; Bera, Sudipta K; Banerjee, Ayan

    2014-06-01

    We describe a simple yet powerful technique of simultaneously measuring both translational and rotational motion of mesoscopic particles in optical tweezers by measuring the backscattered intensity on a quadrant photodiode (QPD). While the measurement of translational motion by taking the difference of the backscattered intensity incident on adjacent quadrants of a QPD is well known, we demonstrate that rotational motion can be measured very precisely by taking the difference between the diagonal quadrants. The latter measurement eliminates the translational component entirely and leads to a detection sensitivity of around 50 mdeg at S/N of 2 for angular motion of a driven microrod. The technique is also able to resolve the translational and rotational Brownian motion components of the microrod in an unperturbed trap and can be very useful in measuring translation-rotation coupling of micro-objects induced by hydrodynamic interactions.

  10. The RHIC p-Carbon CNI Polarimeter Upgrade For The Beam Polarization And Intensity Measurements

    SciTech Connect

    Zelenski, A.; Bazilevski, A.; Bunce, G.; Gill, R.; Huang, H.; Mahler, G.; Makdisi, Y.; Morozov, B.; Nemesure, S.; Russo, T.; Steski, D.; Sivertz, M.

    2009-08-04

    Proton polarization measurements in the AGS and RHIC (Relativistic Heavy Ion Collider at the beam energies 24-250 GeV) are based on proton-carbon and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. Polarimeter operation in the scanning mode also gives polarization profile and beam intensity profile (beam emittance) measurements. Bunch by bunch emittance measurement is a very powerful tool for machine setup. Presently, the polarization and beam intensity profile measurements (in both vertical and horizontal planes) are restricted by the long target switching time and possible target destruction during this complicated motion. The RHIC polarimeters were operated near the limit of the counting rate for present silicon strip detectors. The ongoing polarimeter upgrade for the 2009 run will address all these problems. The upgrade should allow significant reduction of the polarization measurement errors by making feasible the complete polarization measurements, which includes polarization profiles in both the horizontal and vertical planes.

  11. Direct measurement of transmission loss of aircraft structures using the acoustic intensity approach

    NASA Technical Reports Server (NTRS)

    Wang, Y. S.; Crocker, M. J.

    1982-01-01

    A measurement technique is developed in order to obtain the sound transmission loss of an aircraft fuselage which obviates the need for the two-room transmission suite. The sound transmission paths were determined in tests on a light aircraft fuselage using a two-microphone acoustic intensity method for measuring the acoustic intensity transmitted to the interior when the fuselage was exposed to an external random incidence sound-field. The intensity transmitted through different sections of the fuselage can be estimated accurately using this new technique. Results of these tests show that the plexiglass window is the major transmission path in the high frequency range. In addition, the transmission losses through a single and a double layer window were predicted theoretically by using the Statistical Energy Analysis Model. Very good agreement is found between the predictions and the measurements.

  12. Acoustical studies of the steelpan and HANG: Phase-sensitive holography and sound intensity measurements

    NASA Astrophysics Data System (ADS)

    Morrison, Andrew C. H.

    The Caribbean steelpan and an instrument closely related, the HANG, are two of the most, interesting acoustic musical instruments developed in the last century. Although simple in design, the acoustic properties of the steelpan and HANG are surprisingly complicated. Holographic interferometry was used to determine the resonances of a low tenor steelpan and a pentatonic HANG. Placement of a vibrating mirror in the optical path of the reference beam expands the capabilities of the holography system to include phase measurements. Phase maps and phase response curves of several low resonances of notes on a steelpan and HANG are shown. Sound intensity measurements were acquired to explore the relationship between the resonances and the radiated sound field. The instruments were placed in an anechoic chamber, and selected notes were excited electromagnetically with a swept sinusoid signal. A two-microphone probe was used to gather sound intensity measurements. Sound intensity reaps of the first three harmonics are shown for notes on both instruments.

  13. Rapid directional change degrades GPS distance measurement validity during intermittent intensity running.

    PubMed

    Rawstorn, Jonathan C; Maddison, Ralph; Ali, Ajmol; Foskett, Andrew; Gant, Nicholas

    2014-01-01

    Use of the Global Positioning System (GPS) for quantifying athletic performance is common in many team sports. The effect of running velocity on measurement validity is well established, but the influence of rapid directional change is not well understood in team sport applications. This effect was systematically evaluated using multidirectional and curvilinear adaptations of a validated soccer simulation protocol that maintained identical velocity profiles. Team sport athletes completed 90 min trials of the Loughborough Intermittent Shuttle-running Test movement pattern on curvilinear, and multidirectional shuttle running tracks while wearing a 5 Hz (with interpolated 15 Hz output) GPS device. Reference total distance (13 200 m) was systematically over- and underestimated during curvilinear (2.61±0.80%) and shuttle (-3.17±2.46%) trials, respectively. Within-epoch measurement uncertainty dispersion was widest during the shuttle trial, particularly during the jog and run phases. Relative measurement reliability was excellent during both trials (Curvilinear r = 1.00, slope = 1.03, ICC = 1.00; Shuttle r = 0.99, slope = 0.97, ICC = 0.99). Absolute measurement reliability was superior during the curvilinear trial (Curvilinear SEM = 0 m, CV = 2.16%, LOA ± 223 m; Shuttle SEM = 119 m, CV = 2.44%, LOA ± 453 m). Rapid directional change degrades the accuracy and absolute reliability of GPS distance measurement, and caution is recommended when using GPS to quantify rapid multidirectional movement patterns.

  14. Design of a Thermoacoustic Sensor for Low Intensity Ultrasound Measurements Based on an Artificial Neural Network.

    PubMed

    Xing, Jida; Chen, Jie

    2015-01-01

    In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous

  15. Design of a Thermoacoustic Sensor for Low Intensity Ultrasound Measurements Based on an Artificial Neural Network.

    PubMed

    Xing, Jida; Chen, Jie

    2015-06-23

    In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous

  16. Ultra soft X-ray Microbeam: optical analysis and intensity measurements

    NASA Astrophysics Data System (ADS)

    Emilio, M. Di Paolo; Palladino, L.; Del Grande, F.

    2016-06-01

    In this work, optical analysis and intensity measurements of the Ultra Soft x-ray microbeam (100 eV–1 keV) are presented. X-ray emission at 500 eV are generated from a plasma produced by focusing Nd-YAG laser beam on the Yttrium target. In particular, we will report the study of x-ray intensity and the measurement of focal spot dimension. Moreover, the software/hardware control of sample holder position and the alignment of biological sample to the microbeam will be described.

  17. Measurements of the absolute value of the penetration depth in high-T{sub c} superconductors using a low-T{sub c} superconductive coating

    SciTech Connect

    Prozorov, R.; Giannetta, R. W.; Carrington, A.; Fournier, P.; Greene, R. L.; Guptasarma, P.; Hinks, D. G.; Banks, A. R.

    2000-12-18

    A method is presented to measure the absolute value of the London penetration depth, {lambda}(T=0), from the frequency shift of a resonator. The technique involves coating a high-T{sub c} superconductor with film of low-T{sub c} material of known thickness and penetration depth. The method is applied to obtain {lambda}(YBa{sub 2}Cu{sub 3}O{sub 7-{delta}}){approx}1460{+-}150Aa, {lambda}(Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}}){approx}2690{+-}150Aa and {lambda}(Pr{sub 1.85}Ce{sub 0.15}CuO{sub 4-{delta}}){approx}2790{+-}150Aa. {lambda}(YBa{sub 2}Cu{sub 3}O{sub 7-{delta}}) from this method is very close to that obtained by several other techniques. For both Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} and Pr{sub 1.85}Ce{sub 0.15}CuO{sub 4-{delta}} the values exceed those obtained by other methods.

  18. Biradical thermochemistry from collision-induced dissociation threshold energy measurements. Absolute heats of formation of ortho-, meta-, and para-benzyne

    SciTech Connect

    Wenthold, P.G.; Squires, R.R. )

    1994-07-13

    The absolute heats of formation of 1,2-, 1,3-, and 1,4-dehydrobenzene (ortho, meta-, and para-benzyne) have been determined from measurements of the threshold energies for collision-induced dissociation (CID) of ortho, meta-, and para-chlorophenyl anions in a flowing afterglow-triple quadrupole apparatus. The 298 K heats of formation for ortho-, meta-, and para-benzyne derived in this manner are 106.6 [+-] 3.0, 122.0 [+-] 3.1, and 137.3 [+-] 3.3 kcal/mol, respectively. The values for meta- and para-benzyne are higher than those reported previously but are in excellent agreement with recently reported MCSCF and CI calculations. Several control experiments are described which demonstrate that the earlier results for meta- and para-benzyne suffered from an acid-catalyzed isomerization of the reactant chlorophenyl anions in the flowing afterglow prior to CID threshold analysis. 70 refs., 5 figs., 4 tabs.

  19. Infiltration and Runoff Measurements on Steep Burned Hillslopes Using a Rainfall Simulator with Variable Rain Intensities

    USGS Publications Warehouse

    Kinner, David A.; Moody, John A.

    2008-01-01

    Multiple rainfall intensities were used in rainfall-simulation experiments designed to investigate the infiltration and runoff from 1-square-meter plots on burned hillslopes covered by an ash layer of varying thickness. The 1-square-meter plots were on north- and south-facing hillslopes in an area burned by the Overland fire northwest of Boulder near Jamestown on the Front Range of Colorado. A single-nozzle, wide-angle, multi-intensity rain simulator was developed to investigate the infiltration and runoff on steep (30- to 40-percent gradient) burned hillslopes covered with ash. The simulated rainfall was evaluated for spatial variability, drop size, and kinetic energy. Fourteen rainfall simulations, at three intensities (about 20 millimeters per hour [mm/h], 35 mm/h, and 50 mm/h), were conducted on four plots. Measurements during and after the simulations included runoff, rainfall, suspended-sediment concentrations, surface ash layer thickness, soil moisture, soil grain size, soil lost on ignition, and plot topography. Runoff discharge reached a steady state within 7 to 26 minutes. Steady infiltration rates with the 50-mm/h application rainfall intensity approached 20?35 mm/h. If these rates are projected to rainfall application intensities used in many studies of burned area runoff production (about 80 mm/h), the steady discharge rates are on the lower end of measurements from other studies. Experiments using multiple rainfall intensities (three) suggest that runoff begins at rainfall intensities around 20 mm/h at the 1-square-meter scale, an observation consistent with a 10-mm/h rainfall intensity threshold needed for runoff initiation that has been reported in the literature.

  20. New 33 GHz Measurements of the Cosmic Background RadiationIntensity

    SciTech Connect

    De Amici, G.; Smoot, G.; Friedman, S.G.; Witebsky, C.

    1985-03-01

    New measurements have been made of the intensity of the cosmic background radiation (CBR) at 33 GHz (0.91 cm). The experiment was part of a larger effort to measure the spectrum of the CBR between 2.5 and 90 GHz (12 and 0.33 cm). Details are given of the experimental equipment and measurement procedures. The results of measurements made in 1982 and 1983 are presented and discussed in relation to preliminary results from the other radiometers. The measured value, T{sub CBR} = (2.81 {+-} 0.12) K, is in very good agreement both with those previously published and those reported by our collaborators.