  1. Non-invasive determination of absolute lung resistivity in adults using electrical impedance tomography.

    PubMed

    Zhang, Jie; Patterson, Robert

    2010-08-01

    Lung resistivity is a physiological parameter that describes the electrical characteristics of the lungs. Lung composition changes due to changes in the lung tissues, fluid and air volume. Various diseases that can cause a change in lung composition may be monitored by measuring lung resistivity. Currently, there is no accepted non-invasive method to measure lung resistivity. In this study, we presented a method and framework to non-invasively determine lung resistivity using electrical impedance tomography (EIT). By comparing actual measurements from subjects with data from a 3D human thorax model, an EIT image can be reconstructed to show a resistivity difference between the model and the subject. By adjusting the lung resistivity in the model, the resistivity difference in the lung regions can be reduced to near zero. This resistivity value then is the estimation of the lung resistivity of the subject. Using the proposed method, the lung resistivities of four normal adult males (43 +/- 13 years, 78 +/- 10 kg) in the supine position at air volumes starting at functional residual capacity (FRC--end expiration) and increasing in 0.5 l steps to 1.5 l were studied. The averaged lung resistivity changes 12.59%, from 1406 Omega cm to 1583 Omega cm, following the inspiration of 1.5 l air from FRC. The coefficients of variation (CV) of precision for the four subjects are less than 10%. The experiment was repeated five times at each air volume on a subject to test the reproducibility. The CVs are less than 3%. The results show that it is feasible to determine absolute lung resistivity using an EIT-based method.

  2. [ENDOSCOPIC LUNG VOLUME REDUCTION IN PULMONARY EMPHYSEMA].

    PubMed

    Duysinx, B; Heinen, V; Louis, R; Corhay, J-L

    2015-12-01

    Emphysema is characterized by an irreversible alveolar destruction, a progressive lung hyperinflation and a dysfunction of respiratory muscles. It induces a respiratory functional limitation and a decrease of quality of life. Endoscopic lung volume reduction represents a potential alternative to surgical treatments for advanced heterogeneous emphysema without concomitant surgical morbidity. The different bronchoscopic systems for lung volume reduction currently under evaluation are presented.

  3. Lung Volume Recruitment in Multiple Sclerosis

    PubMed Central

    Srour, Nadim; LeBlanc, Carole; King, Judy; McKim, Douglas A.

    2013-01-01

    Introduction Pulmonary function abnormalities have been described in multiple sclerosis including reductions in forced vital capacity (FVC) and cough but the time course of this impairment is unknown. Peak cough flow (PCF) is an important parameter for patients with respiratory muscle weakness and a reduced PCF has a direct impact on airway clearance and may therefore increase the risk of respiratory tract infections. Lung volume recruitment is a technique that improves PCF by inflating the lungs to their maximal insufflation capacity. Objectives Our goals were to describe the rate of decline of pulmonary function and PCF in patients with multiple sclerosis and describe the use of lung volume recruitment in this population. Methods We reviewed all patients with multiple sclerosis referred to a respiratory neuromuscular rehabilitation clinic from February 1999 until December 2010. Lung volume recruitment was attempted in patients with FVC <80% predicted. Regular twice daily lung volume recruitment was prescribed if it resulted in a significant improvement in the laboratory. Results There were 79 patients included, 35 of whom were seen more than once. A baseline FVC <80% predicted was present in 82% of patients and 80% of patients had a PCF insufficient for airway clearance. There was a significant decline in FVC (122.6 mL/y, 95% CI 54.9–190.3) and PCF (192 mL/s/y, 95% 72–311) over a median follow-up time of 13.4 months. Lung volume recruitment was associated with a slower decline in FVC (p<0.0001) and PCF (p = 0.042). Conclusion Pulmonary function and cough decline significantly over time in selected patients with multiple sclerosis and lung volume recruitment is associated with a slower rate of decline in lung function and peak cough flow. Given design limitations, additional studies are needed to assess the role of lung volume recruitment in patients with multiple sclerosis. PMID:23383293

  4. Effect of Lung Volume on Voice Onset Time (VOT).

    ERIC Educational Resources Information Center

    Hoit, Jeannette D.; And Others

    1993-01-01

    Five men repeated a phrase, beginning at total lung capacity and ending at residual volume. Analysis indicated that voice onset time (VOT) was longer at high lung volumes and shorter at low lung volumes. Lung volume should, therefore, be considered when using VOT as an index of laryngeal behavior in healthy and speech-disordered individuals.…

  5. Lung volumes in giraffes, Giraffa camelopardalis.

    PubMed

    Mitchell, G; Skinner, J D

    2011-01-01

    We have measured lung mass and trachea dimensions in 46 giraffes of both genders ranging in body mass from 147 kg to 1441 kg, calculated static and dynamic lung volumes, and developed allometric equations that relate changes in them to growth. We found that relative lung mass is 0.6±0.2% of body mass which is significantly less than it is in other mammals (1.1±0.1%). Total lung volume is significantly smaller (46.2±5.9 mL kg⁻¹) than in similar sized mammals (75.0±2.1 mL kg⁻¹). The lung volume:body mass ratio decreases during growth rather than increase as it does in other mammals. Tracheal diameter is significantly narrower than in similar sized mammals but dead space volume (2.9±0.5 mL kg⁻¹) is larger than in similar sized mammals (2.4±0.1 mL kg⁻¹). Our calculations suggest that tidal volume (10.5±0.2 mL kg⁻¹) is increased compared to that in other mammals(10.0±0.2 mL kg⁻¹) so that the dead space:tidal volume ratio is the same as in other mammals. Calculated Functional Residual Capacity is smaller than predicted (53.4±3.5 vs 33.7±0.6 mL kg⁻¹) as is Expiratory Reserve Volume (47.4±2.6 vs 27.2±1.0 mL kg⁻¹, but Residual Volume (6.0±0.4 mL kg⁻¹) is the same as in other similar sized mammals (6.0±0.9 mL kg⁻¹. Our calculations suggest that Inspiratory Reserve Volume is significantly reduced in size (11.6±1.6 vs 3.8±2.4 mL kg⁻¹), and, if so, the capacity to increase tidal volume is limited. Calculated dynamic lung volumes were the same as in similar sized mammals. We have concluded that giraffe morphology has resulted in lung volumes that are significantly different to that of similar sized mammals, but these changes do not compromise ventilatory capacity.

  6. Sequential unilateral lung volume reduction for emphysema - Stretching the benefit.

    PubMed

    Khorramnia, Sadie; Holsworth, Lynda; Mestitz, Hugh; Westall, Glen P; Williams, Trevor J; Gooi, Julian H; Snell, Gregory I

    2017-01-01

    Bronchoscopic Lung Volume Reduction (BLVR) and Surgical Lung Volume Reduction (SLVR) and are two different approaches used to remodel severely emphysematous lungs to improve lung function and quality-of-life. We present a case initially referred for lung transplantation, where sequential left upper lobe BLVR and 7 years later right upper lobe SLVR, providing enduring physiological and functional improvement. The potential for sustained benefit via sequential unilateral lung volume reduction is under-appreciated.

  7. Linear dimensions and volumes of human lungs

    SciTech Connect

    Hickman, David P.

    2012-03-30

    TOTAL LUNG Capacity is defined as “the inspiratory capacity plus the functional residual capacity; the volume of air contained in the lungs at the end of a maximal inspiration; also equals vital capacity plus residual volume” (from MediLexicon.com). Within the Results and Discussion section of their April 2012 Health Physics paper, Kramer et al. briefly noted that the lungs of their experimental subjects were “not fully inflated.” By definition and failure to obtain maximal inspiration, Kramer et. al. did not measure Total Lung Capacity (TLC). The TLC equation generated from this work will tend to underestimate TLC and does not improve or update total lung capacity data provided by ICRP and others. Likewise, the five linear measurements performed by Kramer et. al. are only representative of the conditions of the measurement (i.e., not at-rest volume, but not fully inflated either). While there was significant work performed and the data are interesting, the data does not represent a maximal situation, a minimal situation, or an at-rest situation. Moreover, while interesting, the linear data generated by this study is limited by the conditions of the experiment and may not be fully comparative with other lung or inspiratory parameters, measures, or physical dimensions.

  8. Linear dimensions and volumes of human lungs

    DOE PAGES

    Hickman, David P.

    2012-03-30

    TOTAL LUNG Capacity is defined as “the inspiratory capacity plus the functional residual capacity; the volume of air contained in the lungs at the end of a maximal inspiration; also equals vital capacity plus residual volume” (from MediLexicon.com). Within the Results and Discussion section of their April 2012 Health Physics paper, Kramer et al. briefly noted that the lungs of their experimental subjects were “not fully inflated.” By definition and failure to obtain maximal inspiration, Kramer et. al. did not measure Total Lung Capacity (TLC). The TLC equation generated from this work will tend to underestimate TLC and does notmore » improve or update total lung capacity data provided by ICRP and others. Likewise, the five linear measurements performed by Kramer et. al. are only representative of the conditions of the measurement (i.e., not at-rest volume, but not fully inflated either). While there was significant work performed and the data are interesting, the data does not represent a maximal situation, a minimal situation, or an at-rest situation. Moreover, while interesting, the linear data generated by this study is limited by the conditions of the experiment and may not be fully comparative with other lung or inspiratory parameters, measures, or physical dimensions.« less

  9. Quantitative measurement of regional lung gas volume by synchrotron radiation computed tomography

    NASA Astrophysics Data System (ADS)

    Monfraix, Sylvie; Bayat, Sam; Porra, Liisa; Berruyer, Gilles; Nemoz, Christian; Thomlinson, William; Suortti, Pekka; Sovijärvi, Anssi R. A.

    2005-01-01

    The aim of this study was to assess the feasibility of a novel respiration-gated spiral synchrotron radiation computed tomography (SRCT) technique for direct quantification of absolute regional lung volumes, using stable xenon (Xe) gas as an inhaled indicator. Spiral SRCT with K-edge subtraction using two monochromatic x-ray beams was used to visualize and directly quantify inhaled Xe concentrations and airspace volumes in three-dimensional (3D) reconstructed lung images. Volume measurements were validated using a hollow Xe-filled phantom. Spiral images spanning 49 mm in lung height were acquired following 60 breaths of an 80% Xe-20% O2 gas mixture, in two anaesthetized and mechanically ventilated rabbits at baseline and after histamine aerosol inhalation. Volumetric images of 20 mm lung sections were obtained at functional residual capacity (FRC) and at end-inspiration. 3D images showed large patchy filling defects in peripheral airways and alveoli following histamine provocation. Local specific lung compliance was calculated based on FRC/end-inspiration images in normal lung. This study demonstrates spiral SRCT as a new technique for direct determination of regional lung volume, offering possibilities for non-invasive investigation of regional lung function and mechanics, with a uniquely high spatial resolution. An example of non-uniform volume distribution in rabbit lung following histamine inhalation is presented.

  10. Lung volume reduction surgery for emphysema.

    PubMed

    Flaherty, K R; Martinez, F J

    2000-12-01

    Over the past decades, extensive literature has been published regarding surgical therapies for advanced COPD. Lung-volume reduction surgery would be an option for a significantly larger number of patients than classic bullectomy or lung transplantation. Unfortunately, the initial enthusiasm has been tempered by major questions regarding the optimal surgical approach, safety, firm selection criteria, and confirmation of long-term benefits. In fact, the long-term follow-up reported in patients undergoing classical bullectomy should serve to caution against unbridled enthusiasm for the indiscriminate application of LVRS. Those with the worst long-term outcome despite favourable short-term improvements after bullectomy have consistently been those with the lowest pulmonary function and significant emphysema in the remaining lung who appear remarkably similar to those being evaluated for LVRS. With this in mind, the National Heart, Lung and Blood Institute partnered with the Health Care Finance Administration to establish a multicenter, prospective, randomized study of intensive medical management, including pulmonary rehabilitation versus the same plus bilateral (by MS or VATS), known as the National Emphysema Treatment Trial. The primary objectives are to determine whether LVRS improves survival and exercise capacity. The secondary objectives will examine effects on pulmonary function and HRQL, compare surgical techniques, examine selection criteria for optimal response, identify criteria to determine those who are at prohibitive surgical risk, and examine long-term cost effectiveness. It is hoped that data collected from this novel, multicenter collaboration will place the role of LVRS in a clearer perspective for the physician caring for patients with advanced emphysema.

  11. Lung Volume Measured during Sequential Swallowing in Healthy Young Adults

    ERIC Educational Resources Information Center

    Hegland, Karen Wheeler; Huber, Jessica E.; Pitts, Teresa; Davenport, Paul W.; Sapienza, Christine M.

    2011-01-01

    Purpose: Outcomes from studying the coordinative relationship between respiratory and swallow subsystems are inconsistent for sequential swallows, and the lung volume at the initiation of sequential swallowing remains undefined. The first goal of this study was to quantify the lung volume at initiation of sequential swallowing ingestion cycles and…

  12. VARIATION OF LUNG DEPOSITION OF MICRON SIZE PARTICLES WITH LUNG VOLUME AND BREATHING PATTERN

    EPA Science Inventory

    Lung volume and breathing pattern are the source of inter-and intra-subject variability of lung deposition of inhaled particles. Controlling these factors may help optimize delivery of aerosol medicine to the target site within the lung. In the present study we measured total lu...

  13. Radiation Dose-Volume Effects in the Lung

    SciTech Connect

    Marks, Lawrence B.; Bentzen, Soren M. D.Sc.; Deasy, Joseph O.; Kong, F.-M.; Bradley, Jeffrey D.; Vogelius, Ivan S.; El Naqa, Issam; Hubbs, Jessica L. M.S.; Lebesque, Joos V.; Timmerman, Robert D.; Martel, Mary K.; Jackson, Andrew

    2010-03-01

    The three-dimensional dose, volume, and outcome data for lung are reviewed in detail. The rate of symptomatic pneumonitis is related to many dosimetric parameters, and there are no evident threshold 'tolerance dose-volume' levels. There are strong volume and fractionation effects.

  14. Influence of lung volume in sleep apnoea.

    PubMed Central

    Sériès, F; Cormier, Y; Lampron, N; La Forge, J

    1989-01-01

    The influence of a constant increase in functional residual capacity on apnoea characteristics was studied in patients with the sleep apnoea syndrome. Pulmonary inflation was achieved by applying a continuous negative extrathoracic pressure into a Poncho type respirator. Nine patients slept in the Poncho for two consecutive nights, negative extrathoracic pressure being applied during the second night. There was no difference in the total sleep time, its composition within the different sleep stages, the apnoea and apnoea-hypopnoea indices, or the sleep time spent in apnoea between the two nights. The mean (SD) apnoea duration increased with negative extrathoracic pressure from 25.3 (2) to 30.5 (3) seconds (p = 0.003) and time spent in obstructive apnoea (percentage of apnoea time) from 56 (13) to 75 (8) (p = 0.02). The mixed apnoea time (%) decreased from 37 (7) to 21 (7) (p = 0.02). Despite the increase in apnoea duration, less time was spent below each oxygen saturation value during negative extrathoracic pressure. The results were similar for apnoeic episodes during non-REM (non-rapid eye movement) sleep, whereas no significant modifications were seen during REM sleep. It is concluded that the composition of apnoea time and resulting oxygen desaturation are influenced by lung volume. PMID:2928988

  15. Influence of lung volume in sleep apnoea.

    PubMed

    Sériès, F; Cormier, Y; Lampron, N; La Forge, J

    1989-01-01

    The influence of a constant increase in functional residual capacity on apnoea characteristics was studied in patients with the sleep apnoea syndrome. Pulmonary inflation was achieved by applying a continuous negative extrathoracic pressure into a Poncho type respirator. Nine patients slept in the Poncho for two consecutive nights, negative extrathoracic pressure being applied during the second night. There was no difference in the total sleep time, its composition within the different sleep stages, the apnoea and apnoea-hypopnoea indices, or the sleep time spent in apnoea between the two nights. The mean (SD) apnoea duration increased with negative extrathoracic pressure from 25.3 (2) to 30.5 (3) seconds (p = 0.003) and time spent in obstructive apnoea (percentage of apnoea time) from 56 (13) to 75 (8) (p = 0.02). The mixed apnoea time (%) decreased from 37 (7) to 21 (7) (p = 0.02). Despite the increase in apnoea duration, less time was spent below each oxygen saturation value during negative extrathoracic pressure. The results were similar for apnoeic episodes during non-REM (non-rapid eye movement) sleep, whereas no significant modifications were seen during REM sleep. It is concluded that the composition of apnoea time and resulting oxygen desaturation are influenced by lung volume.

  16. Simple and accurate empirical absolute volume calibration of a multi-sensor fringe projection system

    NASA Astrophysics Data System (ADS)

    Gdeisat, Munther; Qudeisat, Mohammad; AlSa`d, Mohammed; Burton, David; Lilley, Francis; Ammous, Marwan M. M.

    2016-05-01

    This paper suggests a novel absolute empirical calibration method for a multi-sensor fringe projection system. The optical setup of the projector-camera sensor can be arbitrary. The term absolute calibration here means that the centre of the three dimensional coordinates in the resultant calibrated volume coincides with a preset centre to the three-dimensional real-world coordinate system. The use of a zero-phase fringe marking spot is proposed to increase depth calibration accuracy, where the spot centre is determined with sub-pixel accuracy. Also, a new method is proposed for transversal calibration. Depth and transversal calibration methods have been tested using both single sensor and three-sensor fringe projection systems. The standard deviation of the error produced by this system is 0.25 mm. The calibrated volume produced by this method is 400 mm×400 mm×140 mm.

  17. What is the clinical value of lung volumes?

    PubMed

    Ruppel, Gregg L

    2012-01-01

    Lung volumes are considered part of a complete pulmonary function test, but their value for enhancing clinical decision making is unknown. Unlike spirometry and diffusing capacity of the lung for carbon monoxide (D(LCO)), which do contribute to confirming or excluding a diagnosis, there are few clear indications when lung volumes are discriminatory. Confirming "restriction" when vital capacity (VC) or FVC is reduced is perhaps the most important. A restrictive pattern can have many etiologies, and clinicians often use VC or FVC as a primary index of lung volume. This makes "physiologic" sense because, in healthy subjects, and in patients with true restriction, VC comprises most of the total lung capacity (TLC). Mixed obstruction-restriction and the nonspecific pattern (ie, reduced FVC and FEV(1), normal FEV(1)/FVC and TLC) require measuring TLC to confirm the underlying physiology. In obesity, VC and TLC may remain within normal limits, but functional residual capacity (FRC) can exponentially decrease. Increased lung volumes, particularly residual volume (RV), are commonly observed in airway obstruction. TLC may be normal, but is frequently increased in the late stages of COPD. Hyperinflation and air-trapping are terms commonly used to reflect these changes, but are not well standardized. The variability of lung volumes related to degree of obstruction suggests that measuring gas-trapping may be needed to monitor therapy. Changes in inspiratory capacity, RV, or FRC may be important gauges of response to bronchodilators or other hyperinflation-reducing therapies. How lung volumes are measured may be important, especially in patients who have moderate or severe airway obstruction. Body plethysmography is often considered more accurate than gas dilution methods in the presence of obstruction. However, the differences between techniques are not completely understood. Newer approaches such as computed tomography, although not suitable for routine testing, may help to

  18. High lung volume increases stress failure in pulmonary capillaries

    NASA Technical Reports Server (NTRS)

    Fu, Z.; Costello, M. L.; Tsukimoto, K.; Prediletto, R.; Elliott, A. R.; Mathieu-Costello, O.; West, J. B.

    1992-01-01

    We previously showed that when pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to test whether stress failure occurred more frequently at high than at low lung volumes for the same Ptm. Lungs of anesthetized rabbits were inflated to a transpulmonary pressure of 20 cmH2O, perfused with autologous blood at 32.5 or 2.5 cmH2O Ptm, and fixed by intravascular perfusion. Samples were examined by both transmission and scanning electron microscopy. The results were compared with those of a previous study in which the lung was inflated to a transpulmonary pressure of 5 cmH2O. There was a large increase in the frequency of stress failure of the capillary walls at the higher lung volume. For example, at 32.5 cmH2O Ptm, the number of endothelial breaks per millimeter cell lining was 7.1 +/- 2.2 at the high lung volume compared with 0.7 +/- 0.4 at the low lung volume. The corresponding values for epithelium were 8.5 +/- 1.6 and 0.9 +/- 0.6. Both differences were significant (P less than 0.05). At 52.5 cmH2O Ptm, the results for endothelium were 20.7 +/- 7.6 (high volume) and 7.1 +/- 2.1 (low volume), and the corresponding results for epithelium were 32.8 +/- 11.9 and 11.4 +/- 3.7. At 32.5 cmH2O Ptm, the thickness of the blood-gas barrier was greater at the higher lung volume, consistent with the development of more interstitial edema. Ballooning of the epithelium caused by accumulation of edema fluid between the epithelial cell and its basement membrane was seen at 32.5 and 52.5 cmH2O Ptm. At high lung volume, the breaks tended to be narrower and fewer were oriented perpendicular to the axis of the pulmonary capillaries than at low lung volumes. Transmission and scanning electron microscopy measurements agreed well. Our findings provide a physiological

  19. Single lung alveolar volume and gas transfer: effect of expansion of the other lung.

    PubMed Central

    Johansen, B.; Bjørtuft, O.

    1994-01-01

    BACKGROUND--Temporary occlusion of one mainstem bronchus permits measurement of single lung function. A previous study suggested that the volume at which one lung is occluded may influence the expansion of the other. The effect of ipsilateral occlusion volume on the contralateral effective alveolar volume (VA, EFF,SL), inspired volume (VI,SL), single breath estimated residual volume (RVSB,SL), carbon monoxide (CO) transfer (TLCO,SL) and transfer coefficient (KCO,SL) has been examined. METHODS--Single breath measurements of CO transfer were made in duplicate in 12 healthy subjects aged 19-44 years, without and during occlusion of one mainstem bronchus by a balloon at RV and at total lung capacity (TLC). RESULTS--Mean VA,EFF,SL, VI,SL, and TLCO,SL were lower during occlusion at RV than during occlusion at TLC (2.84 v 3.26 l; 2.18 v 2.54 l; and 4.70 v 5.51 mmol/kPa/min respectively). RVSB,SL was independent of occlusion volume and KCO,SL not different from the KCO of both lungs (KCO,BL). Single lung values during occlusion at TLC were fairly reproducible and were, except for KCO,SL, approximately half the values for both lungs. During occlusion at RV the second TLCO,SL and KCO,SL were lower than the first. CONCLUSIONS--Occlusion of one lung permits reliable determinations of gas transfer indices of the other, provided the lung is occluded at TLC. Occlusion at RV significantly reduces VA,EFF,SL, and hence TLCO,SL, but does not affect KCO,SL of the other lung. PMID:7878561

  20. Expiratory flow limitation and operating lung volumes during exercise in older and younger adults.

    PubMed

    Smith, Joshua R; Kurti, Stephanie P; Meskimen, Kayla; Harms, Craig A

    2017-02-20

    We determined the effect of aging on expiratory flow limitation (EFL) and operating lung volumes when matched for lung size. We hypothesized that older adults will exhibit greater EFL and increases in EELV during exercise compared to younger controls. Ten older (5M/5W; >60years old) and nineteen height-matched young adults (10M/9W) were recruited. Young adults were matched for%predicted forced vital capacity (FVC) (Y-matched%Pred FVC; n=10) and absolute FVC (Y-matched FVC; n=10). Tidal flow-volume loops were recorded during the incremental exercise test with maximal flow-volume loops measured pre- and post-exercise. Compared to younger controls, older adults exhibited more EFL at ventilations of 26, 35, 51, and 80L/min. The older group had higher end-inspiratory lung volume compared to Y-matched%Pred FVC group during submaximal ventilations. The older group increased EELV during exercise, while EELV stayed below resting in the Y-matched%Pred FVC group. These data suggest older adults exhibit more EFL and increase EELV earlier during exercise compared to younger adults.

  1. Low Tidal Volume Ventilation in Patients Without Acute Lung Injury.

    PubMed

    Tang, Weibing; Wang, Zhi; Liu, Ye; Zhu, Jing

    2015-05-01

    Acute respiratory distress syndrome is a life threatening respiratory condition characterized by breakdown of the alveolar-capillary barrier, leading to flooding of the alveolar space producing the classical chest radiograph of bilateral pulmonary infiltrates. In this study, we employed lung protective ventilation strategies in patients without acute lung injury (ALI) to determine whether mechanical ventilation with lower tidal volume would provide more clinical benefits to patients without ALI.

  2. Measurement of absolute arterial cerebral blood volume in human brain without using a contrast agent.

    PubMed

    Hua, Jun; Qin, Qin; Pekar, James J; van Zijl, Peter C M

    2011-12-01

    Arterial cerebral blood volume (CBV(a) ) is a vital indicator of tissue perfusion and vascular reactivity. We extended the recently developed inflow vascular-space-occupancy (iVASO) MRI technique, which uses spatially selective inversion to suppress the signal from blood flowing into a slice, with a control scan to measure absolute CBV(a) using cerebrospinal fluid (CSF) for signal normalization. Images were acquired at multiple blood nulling times to account for the heterogeneity of arterial transit times across the brain, from which both CBV(a) and arterial transit times were quantified. Arteriolar CBV(a) was determined separately by incorporating velocity-dependent bipolar crusher gradients. Gray matter (GM) CBV(a) values (n=11) were 2.04 ± 0.27 and 0.76 ± 0.17 ml blood/100 ml tissue without and with crusher gradients (b=1.8 s/mm(2) ), respectively. Arterial transit times were 671 ± 43 and 785 ± 69 ms, respectively. The arterial origin of the signal was validated by measuring its T(2) , which was within the arterial range. The proposed approach does not require exogenous contrast agent administration, and provides a non-invasive alternative to existing blood volume techniques for mapping absolute CBV(a) in studies of brain physiology and neurovascular diseases.

  3. Measurement of lung fluid volumes and albumin exclusion in sheep

    SciTech Connect

    Pou, N.A.; Roselli, R.J.; Parker, R.E.; Clanton, J.A.; Harris, T.R. )

    1989-10-01

    A radioactive tracer technique was used to determine interstitial diethylenetriaminepentaacetic acid (DTPA) and albumin distribution volume in sheep lungs. {sup 125}I- and/or {sup 131}I-labeled albumin were injected intravenously and allowed to equilibrate for 24 h. {sup 99m}Tc-labeled DTPA and {sup 51}Cr-labeled erythrocytes were injected and allowed to equilibrate (2 h and 15 min, respectively) before a lethal dose of thiamylal sodium. Two biopsies (1-3 g) were taken from each lung and the remaining tissue was homogenized for wet-to-dry lung weight and volume calculations. Estimates of distribution volumes from whole lung homogenized samples were statistically smaller than biopsy samples for extravascular water, interstitial {sup 99m}Tc-DTPA, and interstitial albumin. The mean fraction of the interstitium (Fe), which excludes albumin, was 0.68 +/- 0.04 for whole lung samples compared with 0.62 +/- 0.03 for biopsy samples. Hematocrit may explain the consistent difference. To make the Fe for biopsy samples match that for homogenized samples, a mean hematocrit, which was 82% of large vessel hematocrit, was required. Excluded volume fraction for exogenous sheep albumin was compared with that of exogenous human albumin in two sheep, and no difference was found at 24 h.

  4. Lung Volume Reduction After Stereotactic Ablative Radiation Therapy of Lung Tumors: Potential Application to Emphysema

    SciTech Connect

    Binkley, Michael S.; Shrager, Joseph B.; Leung, Ann N.; Popat, Rita; Trakul, Nicholas; Atwood, Todd F.; Chaudhuri, Aadel; Maxim, Peter G.; Diehn, Maximilian; Loo, Billy W.

    2014-09-01

    Purpose: Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema. Methods and Materials: We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and ≥6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABR and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, α/β = 3). Results: 27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade ≥3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, −0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, −3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED ≥60 Gy (r{sup 2}=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r{sup 2}=0.47, P<.0001). Conclusions: We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across

  5. Low cost biological lung volume reduction therapy for advanced emphysema

    PubMed Central

    Bakeer, Mostafa; Abdelgawad, Taha Taha; El-Metwaly, Raed; El-Morsi, Ahmed; El-Badrawy, Mohammad Khairy; El-Sharawy, Solafa

    2016-01-01

    Background Bronchoscopic lung volume reduction (BLVR), using biological agents, is one of the new alternatives to lung volume reduction surgery. Objectives To evaluate efficacy and safety of biological BLVR using low cost agents including autologous blood and fibrin glue. Methods Enrolled patients were divided into two groups: group A (seven patients) in which autologous blood was used and group B (eight patients) in which fibrin glue was used. The agents were injected through a triple lumen balloon catheter via fiberoptic bronchoscope. Changes in high resolution computerized tomography (HRCT) volumetry, pulmonary function tests, symptoms, and exercise capacity were evaluated at 12 weeks postprocedure as well as for complications. Results In group A, at 12 weeks postprocedure, there was significant improvement in the mean value of HRCT volumetry and residual volume/total lung capacity (% predicted) (P-value: <0.001 and 0.038, respectively). In group B, there was significant improvement in the mean value of HRCT volumetry and (residual volume/total lung capacity % predicted) (P-value: 0.005 and 0.004, respectively). All patients tolerated the procedure with no mortality. Conclusion BLVR using autologous blood and locally prepared fibrin glue is a promising method for therapy of advanced emphysema in term of efficacy, safety as well as cost effectiveness. PMID:27536091

  6. Postmortem lung volume/body weight standards for term and preterm infants.

    PubMed

    De Paepe, Monique E; Shapiro, Svetlana; Hansen, Katrine; Gündoğan, Füsun

    2014-01-01

    Assessment of lung growth is a critical component of the perinatal autopsy. Increased lung liquid content may lead to overestimation of lung growth based on (wet) lung weight. In contrast, lung volume is not influenced by intraalveolar lung liquid. Our aim was to establish age-specific reference values for postmortem lung volume/BW in preterm and term infants. We performed a retrospective analysis of fetuses/infants (16-41 weeks' gestation) without (N = 134) or with (N = 79) risk factors for pulmonary hypoplasia. Lungs were inflated at standardized pressure and volumes determined by water immersion method. Lung volume increased 11-fold between 16 and 41 weeks' gestation, concomitant with a 16-fold increase in BW. Mean lung volume/BW remained constant at 33-34 ml/kg between 16 and 31 weeks' gestation and decreased to 23.4 ml/kg at term. Lung volume/BW of infants with severe risk factors (renal anomalies, diaphragmatic hernia) was significantly lower than age-matched standards. In this group, all fetuses/infants diagnosed as having lung hypoplasia by lung volume/BW also had lung hypoplasia LW/BW standards. However, in infants with "softer" risk factors (rupture of membranes, chromosomal anomalies), 5/26 cases diagnosed with lung hypoplasia based on lung volume/BW had normal LW/BW ratios. In these discrepant cases, lung sections showed significant inflammation and edema, likely accounting for increased wet lung weight. In conclusion, we determined age-specific lung volume/BW reference values for preterm and term infants. In selected situations assessment of lung volume/BW may represent a useful complementary tool to LW/BW for postmortem evaluation of lung size.

  7. Free volume hypothetical scanning molecular dynamics method for the absolute free energy of liquids

    PubMed Central

    White, Ronald P.; Meirovitch, Hagai

    2006-01-01

    The hypothetical scanning (HS) method is a general approach for calculating the absolute entropy, S, and free energy, F, by analyzing Boltzmann samples obtained by Monte Carlo (MC) or molecular dynamics (MD) techniques. With HS applied to a fluid, each configuration i of the sample is reconstructed by gradually placing the molecules in their positions at i using transition probabilities (TPs). With our recent version of HS, called HSMC-EV, each TP is calculated from MC simulations, where the simulated particles are excluded from the volume reconstructed in previous steps. In this paper we remove the excluded volume (EV) restriction, replacing it by a “free volume” (FV) approach. For liquid argon, HSMC-FV leads to an improvement in efficiency over HSMC-EV by a factor of 2–3. Importantly, the FV treatment greatly simplifies the HS implementation for liquids, allowing a much more natural application of the method for MD simulations. Given the success and popularity of MD, the present development of the HSMD method for liquids is an important advancement for HS methodology. Results for the HSMD-FV approach presented here agree well with our HSMC and thermodynamic integration results. The efficiency of HSMD-FV is equivalent to HSMC-EV. The potential use of HSMC(MD)-FV in protein systems with explicit water is discussed. PMID:16774320

  8. Comparison of actual tidal volume in neonatal lung model volume control ventilation using three ventilators.

    PubMed

    Toyama, H; Endo, Y; Ejima, Y; Matsubara, M; Kurosawa, S

    2011-07-01

    In neonates, small changes in tidal volumes (V(T)) may lead to complications. Previous studies have shown a significant difference between ventilator-measured tidal volume and tidal volume delivered (actual V(T)). We evaluated the accuracy of three different ventilators to deliver small V(T) during volume-controlled ventilation. We tested Servo 300, 840 ventilator and Evita 4 Neoflow ventilators with lung models simulating normal and injured neonatal lung compliance models. Gas volume delivered from the ventilator into the test circuit (V(TV)) and actual V(T) to the test lung were measured using Ventrak respiration monitors at set V(T) (30 ml). The gas volume increase of the breathing circuit was then calculated. Tidal volumes of the SV300 and PB840 in both lung models were similar to the set V(T) and the actual tidal volumes in the injured model (20.7 ml and 19.8 ml, respectively) were significantly less than that in the normal model (27.4 ml and 23.4 ml). PB840 with circuit compliance compensation could not improve the actual V(T). V(TV) of the EV4N in the normal and the injured models (37.8 ml and 46.6 ml) were markedly increased compared with set V(T), and actual V(T) were similar to set V(T) in the normal and injured model (30.2 ml and 31.9 ml, respectively). EV4N measuring V(T) close to the lung could match actual V(T) to almost the same value as the set V(T) however the gas volume of the breathing circuit was increased. If an accurate value for the patient's actual V(T) is needed, this V(T) must be measured by a sensor located between the Y-piece and the tracheal tube.

  9. Bridging the etiologic and prognostic outlooks in individualized assessment of absolute risk of an illness: application in lung cancer.

    PubMed

    Karp, Igor; Sylvestre, Marie-Pierre; Abrahamowicz, Michal; Leffondré, Karen; Siemiatycki, Jack

    2016-11-01

    Assessment of individual risk of illness is an important activity in preventive medicine. Development of risk-assessment models has heretofore relied predominantly on studies involving follow-up of cohort-type populations, while case-control studies have generally been considered unfit for this purpose. To present a method for individualized assessment of absolute risk of an illness (as illustrated by lung cancer) based on data from a 'non-nested' case-control study. We used data from a case-control study conducted in Montreal, Canada in 1996-2001. Individuals diagnosed with lung cancer (n = 920) and age- and sex-matched lung-cancer-free subjects (n = 1288) completed questionnaires documenting life-time cigarette-smoking history and occupational, medical, and family history. Unweighted and weighted logistic models were fitted. Model overfitting was assessed using bootstrap-based cross-validation and 'shrinkage.' The discriminating ability was assessed by the c-statistic, and the risk-stratifying performance was assessed by examination of the variability in risk estimates over hypothetical risk-profiles. In the logistic models, the logarithm of incidence-density of lung cancer was expressed as a function of age, sex, cigarette-smoking history, history of respiratory conditions and exposure to occupational carcinogens, and family history of lung cancer. The models entailed a minimal degree of overfitting ('shrinkage' factor: 0.97 for both unweighted and weighted models) and moderately high discriminating ability (c-statistic: 0.82 for the unweighted model and 0.66 for the weighted model). The method's risk-stratifying performance was quite high. The presented method allows for individualized assessment of risk of lung cancer and can be used for development of risk-assessment models for other illnesses.

  10. Pneumothorax as a complication of lung volume recruitment*,**

    PubMed Central

    Westermann, Erik J.A.; Jans, Maurice; Gaytant, Michael A.; Bach, John R.; Kampelmacher, Mike J.

    2013-01-01

    Lung volume recruitment involves deep inflation techniques to achieve maximum insufflation capacity in patients with respiratory muscle weakness, in order to increase peak cough flow, thus helping to maintain airway patency and improve ventilation. One of these techniques is air stacking, in which a manual resuscitator is used in order to inflate the lungs. Although intrathoracic pressures can rise considerably, there have been no reports of respiratory complications due to air stacking. However, reaching maximum insufflation capacity is not recommended in patients with known structural abnormalities of the lungs or chronic obstructive airway disease. We report the case of a 72-year-old woman who had poliomyelitis as a child, developed torsion scoliosis and post-polio syndrome, and had periodic but infrequent asthma attacks. After performing air stacking for 3 years, the patient suddenly developed a pneumothorax, indicating that this technique should be used with caution or not at all in patients with a known pulmonary pathology PMID:23857693

  11. Temporal Lung Tumor Volume Changes in Small-Cell Lung Cancer Patients Undergoing Chemoradiotherapy

    SciTech Connect

    Yee, Don; Rathee, Satyapal; Robinson, Don; Murray, Brad

    2011-05-01

    Purpose: Small-cell lung cancer is considered to be relatively chemosensitive and radiosensitive. Small-cell tumor volume changes during concurrent chemoradiotherapy have not been quantified. The purpose of this work is to quantify small-cell lung tumor volume variations in limited-stage patients undergoing chemoradiotherapy. Methods and Materials: Eligible patients had pathologically confirmed limited-stage small-cell lung cancer, underwent concurrent chemoradiotherapy, and signed study-specific consent forms. Patients underwent serial chest computed tomography (CT) scans on a CT simulator with images acquired at the same phase of patients' respiratory cycle. Computed tomography scans were obtained at the time of planning CT scan and 3 times a week during radiotherapy (RT). Gross tumor volumes (GTVs) were contoured on each CT scan. Gross tumor volumes defined on each CT scan were analyzed for volume changes relative to pre-RT scans. Results: We obtained 104 CT scans (median, 11.5 scans per patient). The median tumor dose was 50 Gy. The median pre-RT GTV was 98.9 cm{sup 3} (range, 57.8-412.4 cm{sup 3}). The median GTV at the final serial CT scan was 10.0 cm{sup 3} (range, 4.2-81.6 cm{sup 3}). The mean GTV relative to pre-RT volume at the end of each RT week was 53.0% for Week 1, 29.8% for Week 2, 22.9% for Week 3, 19.5% for Week 4, and 12.4% for Week 5. Conclusions: Dramatic shrinkage of small-cell lung tumors occurred in patients undergoing chemoradiotherapy in this trial. Most of the observed GTV shrinkage occurred during the first week of RT.

  12. Effects of lung volume on clearance of solutes from the air spaces of lungs

    SciTech Connect

    Peterson, B.T.; James, H.L.; McLarty, J.W.

    1988-03-01

    Several investigators have shown that the clearance rate of aerosolized 99mTc-labeled diethylenetriamine pentaacetate (DTPA, mol wt = 492, radius = 0.6 nm) from the air spaces of the lungs of humans and experimental animals increases with lung volume. To further investigate this phenomenon we performed a compartmental analysis of the 2-h clearance of DTPA from the lungs of anesthetized sheep using a new method to more accurately correct for the effects of DTPA recirculation. This analysis showed that the DTPA clearance in eight sheep ventilated with zero end-expired pressure was best described by a one-compartment model with a clearance rate of 0.42 +/- 0.15%/min. Ventilating eight sheep with an end-expired pressure of 10 cmH/sub 2/O throughout the study increased the end-expired volume 0.4 +/- 0.1 liter BTPS and created a clearance curve that was best described by a two-compartment model. In these sheep 56 +/- 16% of the DTPA cleared from the lungs at a rate of 7.9 +/- 2.9%/min. The remainder cleared at a rate similar to that measured in the sheep ventilated with zero end-expired pressure (0.35 +/- 0.18%/min). Additional control and lung inflation experiments were performed using /sup 99m/Tc-labeled human serum albumin (mol wt = 66,000, radius = 3.6 nm). In six control sheep ventilated with zero end-expired pressure the albumin clearance was best described by a one-compartment model with a clearance rate of 0.06 +/- 0.02%/min. The clearance rate in six sheep with increased lung volume was slightly larger (0.09 +/- 0.02, P less than 0.05) but was well described by a one-compartment model.

  13. Lung volumes during sustained microgravity on Spacelab SLS-1

    NASA Technical Reports Server (NTRS)

    Elliott, Ann R.; Prisk, G. Kim; Guy, Harold J. B.; West, John B.

    1994-01-01

    Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (microgravity) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (V9sub T)). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in microgravity and 32% in the supine posture. ERV was reduced by 10 - 20% in microgravity and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in microgravity but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of microgravity but returned to 1-G standing values within 72 h of microgravity exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During microgravity, V(sub T) decreased by 15% (approximately 90 ml), but supine V(sub T) was unchanged compared with preflight standing values. TLC decreased by approximately 8% during microgravity and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during microgravity are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.

  14. [Lung volume reduction surgery for emphysema and bullous pulmonary emphysema].

    PubMed

    Le Pimpec-Barthes, F; Das Neves-Pereira, J-C; Cazes, A; Arame, A; Grima, R; Hubsch, J-P; Zukerman, C; Hernigou, A; Badia, A; Bagan, P; Delclaux, C; Dusser, D; Riquet, M

    2012-04-01

    The improvement of respiratory symptoms for emphysematous patients by surgery is a concept that has evolved over time. Initially used for giant bullae, this surgery was then applied to patients with diffuse microbullous emphysema. The physiological and pathological concepts underlying these surgical procedures are the same in both cases: improve respiratory performance by reducing the high intrapleural pressure. The functional benefit of lung volume reduction surgery (LVRS) in the severe diffuse emphysema has been validated by the National Emphysema Treatment Trial (NETT) and the later studies which allowed to identify prognostic factors. The quality of the clinical, morphological and functional data made it possible to develop recommendations now widely used in current practice. Surgery for giant bullae occurring on little or moderately emphysematous lung is often a simpler approach but also requires specialised support to optimize its results.

  15. Lung Volume Reduction following Recurrent Pneumonia: An Unusual Finding in a COPD Patient

    PubMed Central

    Diaz, Philip T.

    2017-01-01

    Chronic Obstructive Pulmonary Disease (COPD) is a progressive disease. Frequent pneumonias and exacerbations are known to accelerate its progression. We present a case of severe emphysema whose lung function paradoxically improved following recurrent pneumonia, without lung volume reduction surgery (LVRS). A 54-year-old female with severe COPD presented for LVRS evaluation. She was not a candidate for the surgery because of the unsuitable anatomic distribution of her emphysema. The patient experienced recurrent pneumonia over the years but her lung function and oxygen requirement showed marked improvement. Follow-up imaging studies showed decreased lung volumes and focal fibrotic changes. We believe that the improvement in her lung function overtime is the reflection of lung volume reduction as a result of parenchymal remodeling due to repeated lung infection. These findings seen in our patient contribute important information for the continued effort in developing nonsurgical lung volume reduction techniques. PMID:28373884

  16. Perfusion Scintigraphy and Patient Selection for Lung Volume Reduction Surgery

    PubMed Central

    Chandra, Divay; Lipson, David A.; Hoffman, Eric A.; Hansen-Flaschen, John; Sciurba, Frank C.; DeCamp, Malcolm M.; Reilly, John J.; Washko, George R.

    2010-01-01

    Rationale: It is unclear if lung perfusion can predict response to lung volume reduction surgery (LVRS). Objectives: To study the role of perfusion scintigraphy in patient selection for LVRS. Methods: We performed an intention-to-treat analysis of 1,045 of 1,218 patients enrolled in the National Emphysema Treatment Trial who were non–high risk for LVRS and had complete perfusion scintigraphy results at baseline. The median follow-up was 6.0 years. Patients were classified as having upper or non–upper lobe–predominant emphysema on visual examination of the chest computed tomography and high or low exercise capacity on cardiopulmonary exercise testing at baseline. Low upper zone perfusion was defined as less than 20% of total lung perfusion distributed to the upper third of both lungs as measured on perfusion scintigraphy. Measurements and Main Results: Among 284 of 1,045 patients with upper lobe–predominant emphysema and low exercise capacity at baseline, the 202 with low upper zone perfusion had lower mortality with LVRS versus medical management (risk ratio [RR], 0.56; P = 0.008) unlike the remaining 82 with high perfusion where mortality was unchanged (RR, 0.97; P = 0.62). Similarly, among 404 of 1,045 patients with upper lobe–predominant emphysema and high exercise capacity, the 278 with low upper zone perfusion had lower mortality with LVRS (RR, 0.70; P = 0.02) unlike the remaining 126 with high perfusion (RR, 1.05; P = 1.00). Among the 357 patients with non–upper lobe–predominant emphysema (75 with low and 282 with high exercise capacity) there was no improvement in survival with LVRS and measurement of upper zone perfusion did not contribute new prognostic information. Conclusions: Compared with optimal medical management, LVRS reduces mortality in patients with upper lobe–predominant emphysema when there is low rather than high perfusion to the upper lung. PMID:20538961

  17. Lung Cancers Diagnosed at Annual CT Screening: Volume Doubling Times

    PubMed Central

    Yankelevitz, David F.; Yip, Rowena; Reeves, Anthony P.; Farooqi, Ali; Xu, Dongming; Smith, James P.; Libby, Daniel M.; Pasmantier, Mark W.; Miettinen, Olli S.

    2012-01-01

    Purpose: To empirically address the distribution of the volume doubling time (VDT) of lung cancers diagnosed in repeat annual rounds of computed tomographic (CT) screening in the International Early Lung Cancer Action Program (I-ELCAP), first and foremost with respect to rates of tumor growth but also in terms of cell types. Materials and Methods: All CT screenings in I-ELCAP from 1993 to 2009 were performed according to HIPAA-compliant protocols approved by the institutional review boards of the collaborating institutions. All instances of first diagnosis of primary lung cancer after a negative screening result 7–18 months earlier were identified, with symptom-prompted diagnoses included. Lesion diameter was calculated by using the measured length and width of each cancer at the time when the nodule was first identified for further work-up and at the time of the most recent prior screening, 7–18 months earlier. The length and width were measured a second time for each cancer, and the geometric mean of the two calculated diameters was used to calculate the VDT. The χ2 statistic was used to compare the VDT distributions. Results: The median VDT for 111 cancers was 98 days (interquartile range, 108). For 56 (50%) cancers it was less than 100 days, and for three (3%) cancers it was more than 400 days. Adenocarcinoma was the most frequent cell type (50%), followed by squamous cell carcinoma (19%), small cell carcinoma (19%), and others (12%). Lung cancers manifesting as subsolid nodules had significantly longer VDTs than those manifesting as solid nodules (P < .0001). Conclusion: Lung cancers diagnosed in annual repeat rounds of CT screening, as manifest by the VDT and cell-type distributions, are similar to those diagnosed in the absence of screening. © RSNA, 2012 PMID:22454506

  18. SU-E-J-249: Correlation of Mean Lung Ventilation Value with Ratio of Total Lung Volumes

    SciTech Connect

    Yu, N; Qu, H; Xia, P

    2014-06-01

    Purpose: Lung ventilation function measured from 4D-CT and from breathing correlated CT images is a novel concept to incorporate the lung physiologic function into treatment planning of radiotherapy. The calculated ventilation functions may vary from different breathing patterns, affecting evaluation of the treatment plans. The purpose of this study is to correlate the mean lung ventilation value with the ratio of the total lung volumes obtained from the relevant CTs. Methods: A ventilation map was calculated from the variations of voxel-to-voxel CT densities from two breathing phases from either 4D-CT or breathing correlated CTs. An open source image registration tool of Plastimatch was used to deform the inhale phase images to the exhale phase images. To calculate the ventilation map inside lung, the whole lung was delineated and the tissue outside the lung was masked out. With a software tool developed in house, the 3D ventilation map was then converted in the DICOM format associated with the planning CT images. The ventilation map was analyzed on a clinical workstation. To correlate ventilation map thus calculated with lung volume change, the total lung volume change was compared the mean ventilation from our method. Results: Twenty two patients who underwent stereotactic body irradiation for lung cancer was selected for this retrospective study. For this group of patients, the ratio of lung volumes for the inhale (Vin ) and exhale phase (Vex ) was shown to be linearly related to the mean of the local ventilation (Vent), Vin/Vex=1.+0.49*Vent (R2=0.93, p<0.01). Conclusion: The total lung volume change is highly correlated with the mean of local ventilation. The mean of local ventilation may be useful to assess the patient's lung capacity.

  19. Lung Volume during Swallowing: Single Bolus Swallows in Healthy Young Adults

    ERIC Educational Resources Information Center

    Hegland, Karen M. Wheeler; Huber, Jessica E.; Pitts, Teresa; Sapienza, Christine M.

    2009-01-01

    Purpose: This study examined the relationship between swallowing and lung volume initiation in healthy adults during single swallows of boluses differing in volume and consistency. Differences in lung volume according to respiratory phase surrounding the swallow were also assessed. Method: Nine men and 11 women between the ages of 19 and 28 years…

  20. Lung volumes during sustained microgravity on Spacelab SLS-1

    NASA Technical Reports Server (NTRS)

    Elliott, Ann R.; Prisk, Gordon Kim; Guy, Harold J. B.; West, John B.

    1994-01-01

    Gravity is known to influence the topographical gradients of pulmonary ventilation, perfusion, and pleural pressures. The effect of sustained microgravity on lung volumes has not previously been investigated. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box and flowmeter system and a respiratory mass spectrometer. Measurements of tidal volume (V(sub T)), expiratory reserve volume (ERV), inspiratory and expiratory vital capacities (IVC, EVC), functional residual capacity (FRC), and residual volume (RV) were made. During microgravity, V(sub T) decreased by 15%. IVC and EVC were slightly reduced during the first 24 hrs of microgravity and returned to 1 g standing values within 72 hrs after the onset of microgravity. FRC was reduced by 15% and ERV decreased by 10-20%. RV was significantly reduced by 18%. The reductions in FRC, ERV, and V(sub T) during microgravity are probably due to the cranial shift of the diaphragm and an increase in intrathoracic blood volume.

  1. Time for the Global Rollout of Endoscopic Lung Volume Reduction.

    PubMed

    Koegelenberg, Coenraad F N; Slebos, Dirk-Jan; Shah, Pallav L; Theron, Johan; Dheda, Keertan; Allwood, Brian W; Herth, Felix J F

    2015-01-01

    Chronic obstructive pulmonary disease remains one of the most common causes of morbidity and mortality globally. The disease is generally managed with pharmacotherapy, as well as guidance about smoking cessation and pulmonary rehabilitation. Endoscopic lung volume reduction (ELVR) has been proposed for the treatment of advanced emphysema, with the aim of obtaining the same clinical and functional advantages of surgical lung volume reduction whilst potentially reducing risks and costs. There is a growing body of evidence that certain well-defined sub-groups of patients with advanced emphysema may benefit from ELVR, provided the selection criteria are met and a systematic approach is followed. ELVR devices, particularly unidirectional valves and coils, are currently being rolled out to many countries outside of the U.S.A. and Europe, although very few centres currently have the capacity to correctly evaluate and provide ELVR to prospective candidates. The high cost of these interventions underpins the need for careful patient selection to best identify those who may or may not benefit from ELVR-related procedures. The aim of this review is to provide the practicing pulmonologist with an overview of the practical aspects and current evidence for the use of the various techniques available, and to suggest an evidence-based approach for the appropriate use of these devices, particularly in emerging markets, where there should be a drive to develop and equip key specialised ELVR units.

  2. Surgical Approaches to Treating Emphysema: Lung Volume Reduction Surgery, Bullectomy, and Lung Transplantation.

    PubMed

    Marchetti, Nathaniel; Criner, Gerard J

    2015-08-01

    Chronic obstructive pulmonary disease (COPD) is a common and morbid progressive disease where treatment is focused on improving dyspnea, reducing exacerbations, attenuating comorbidities, and improving quality of life. Surgical therapy can be beneficial to a carefully selected subset of individuals and is the subject of this review. The National Emphysema Treatment Trial (NETT) has not only demonstrated the efficacy of lung volume reduction surgery (LVRS) but has also provided many lessons regarding advanced emphysema. NETT demonstrated that LVRS improves exercise performance, quality of life, and pulmonary function in those with upper lobe predominant emphysema in the setting of advanced disease. Those with upper lobe predominant emphysema and low exercise tolerance also had a survival advantage compared with maximal medical therapy. Careful patient selection is paramount to success, as there clearly are patients in whom LVRS increases mortality. Giant bullae are rare, but bullectomy has been demonstrated to improve dyspnea and lung function in cases where the bulla occupies at least one-third of the hemithorax and compresses some adjacent lung tissue. For patients with chronic respiratory failure due to COPD who have not improved despite maximal surgical and medical therapy, lung transplantation remains an option in those without significant comorbid conditions.

  3. Biologic lung volume reduction therapy for advanced homogeneous emphysema.

    PubMed

    Refaely, Y; Dransfield, M; Kramer, M R; Gotfried, M; Leeds, W; McLennan, G; Tewari, S; Krasna, M; Criner, G J

    2010-07-01

    This report summarises phase 2 trial results of biologic lung volume reduction (BioLVR) for treatment of advanced homogeneous emphysema. BioLVR therapy was administered bronchoscopically to 25 patients with homogeneous emphysema in an open-labelled study. Eight patients received low dose (LD) treatment with 10 mL per site at eight subsegments; 17 received high dose (HD) treatment with 20 mL per site at eight subsegments. Safety was assessed in terms of medical complications during 6-month follow-up. Efficacy was assessed in terms of change from baseline in gas trapping, spirometry, diffusing capacity, exercise capacity, dyspnoea and health-related quality of life. There were no deaths or serious medical complications during the study. A statistically significant reduction in gas trapping was observed at 3-month follow-up among HD patients, but not LD patients. At 6 months, changes from baseline in forced expiratory volume in 1 s (-8.0+/-13.93% versus +13.8+/-20.26%), forced vital capacity (-3.9+/-9.41% versus +9.0+/-13.01%), residual volume/total lung capacity ratio (-1.4+/-13.82% versus -5.4+/-12.14%), dyspnoea scores (-0.4+/-1.27 versus -0.8+/-0.73 units) and St George's Respiratory Questionnaire total domain scores (-4.9+/-8.3 U versus -12.2+/-12.38 units) were better with HD than with LD therapy. BioLVR therapy with 20 mL per site at eight subsegmental sites may be a safe and effective therapy in patients with advanced homogeneous emphysema.

  4. Patterns of Lung Volume Use during an Extemporaneous Speech Task in Persons with Parkinson Disease

    ERIC Educational Resources Information Center

    Bunton, K.

    2005-01-01

    This study examined patterns of lung volume use in speakers with Parkinson disease (PD) during an extemporaneous speaking task. The performance of a control group was also examined. Behaviors described are based on acoustic, kinematic and linguistic measures. Group differences were found in breath group duration, lung volume initiation, and lung…

  5. Effects of obesity on lung volume and capacity in children and adolescents: a systematic review

    PubMed Central

    Winck, Aline Dill; Heinzmann-Filho, João Paulo; Soares, Rafaela Borges; da Silva, Juliana Severo; Woszezenki, Cristhiele Taís; Zanatta, Letiane Bueno

    2016-01-01

    Abstract Objective: To assess the effects of obesity on lung volume and capacity in children and adolescents. Data source: This is a systematic review, carried out in Pubmed, Lilacs, Scielo and PEDro databases, using the following Keywords: Plethysmography; Whole Body OR Lung Volume Measurements OR Total Lung Capacity OR Functional Residual Capacity OR Residual Volume AND Obesity. Observational studies or clinical trials that assessed the effects of obesity on lung volume and capacity in children and adolescents (0-18 years) without any other associated disease; in English; Portuguese and Spanish languages were selected. Methodological quality was assessed by the Agency for Healthcare Research and Quality. Data synthesis: Of the 1,030 articles, only four were included in the review. The studies amounted to 548 participants, predominantly males, with sample size ranging from 45 to 327 individuals. 100% of the studies evaluated nutritional status through BMI (z-score) and 50.0% reported the data on abdominal circumference. All demonstrated that obesity causes negative effects on lung volume and capacity, causing a reduction mainly in functional residual capacity in 75.0% of the studies; in the expiratory reserve volume in 50.0% and in the residual volume in 25.0%. The methodological quality ranged from moderate to high, with 75.0% of the studies classified as having high methodological quality. Conclusions: Obesity causes deleterious effects on lung volume and capacity in children and adolescents, mainly by reducing functional residual capacity, expiratory reserve volume and residual volume. PMID:27130483

  6. Incidental lung volume reduction following fulminant pulmonary hemorrhage in a patient with severe emphysema.

    PubMed

    Hetzel, Juergen; Spengler, Werner; Horger, Marius; Boeckeler, Michael

    2015-06-01

    Endoscopic lung volume reduction is an emerging technique meant to improve lung function parameters, quality of life, and exercise tolerance in patients with severe lung emphysema. This is the first report of lung volume reduction by autologous blood in a patient with non-bullous lung emphysema. A 74-year-old woman with heterogeneous lung emphysema developed accidentally diffuse lobar bleeding immediately after valve placement. Due to persistent hemorrhage, the valves had to be removed shortly thereafter. Despite extraction of the valves, respiratory function of the patient improved rapidly indicated also by a drop in the COPD assessment test questionnaire, 3 months later. This was consistent with both improvement of lung function tests and six-minute walking test.

  7. [Normal lung volumes in patients with idiopathic pulmonary fibrosis and emphysema].

    PubMed

    Casas, Juan Pablo; Abbona, Horacio; Robles, Adriana; López, Ana María

    2008-01-01

    Pulmonary function tests in idiopathic pulmonary fibrosis characteristically show a restrictive pattern, resulting from reduction of pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. Previous reports suggest that when both diseases coexist, pulmonary volumes are compensated and a smaller than expected reduction or even normal lung volumes can be found. We report 4 male patients of 64, 60, 73 and 70 years, all with heavy cigarette smoking history and progressive breathlessness. Three of them had severe limitation in their quality of life. All four showed advanced lung interstitial involvement, at high resolution CT scan, fibrotic changes predominantly in the subpleural areas of lower lung fields and concomitant emphysema in the upper lobes. Emphysema and pulmonary fibrosis was confirmed by open lung biopsy in one patient. The four patients showed normal spirometry and lung volumes with severe compromise of gas exchange and poor exercise tolerance evaluated by 6 minute walk test. Severe pulmonary arterial hypertension was also confirmed in three patients. Normal lung volumes does not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.

  8. The role of volume-load in strength and absolute endurance adaptations in adolescent's performing high- or low-load resistance training.

    PubMed

    Steele, James; Fisher, James P; Assunção, Ari R; Bottaro, Martim; Gentil, Paulo

    2017-02-01

    This study compared high- (HL) and low-load (LL) resistance training (RT) on strength, absolute endurance, volume-load, and their relationships in untrained adolescents. Thirty-three untrained adolescents of both sexes (males, n = 17; females, n = 16; 14 ± 1 years) were randomly assigned into either (i) HL (n = 17): performing 3 sets of 4-6 repetitions to momentary concentric failure; or (ii) LL (n = 16): performing 2 sets of 12-15 repetitions to momentary concentric failure. RT was performed for 2×/week for 9 weeks. Change in maximum strength (1 repetition maximum) and absolute muscular endurance for barbell bench press was assessed. Weekly volume-load was calculated as sets (n) × repetitions (n) × load (kg). Ninety-five percent confidence intervals (CIs) revealed that both groups significantly increased in strength and absolute endurance with large effect sizes (d = 1.51-1.66). There were no between-group differences for change in strength or absolute endurance. Ninety-five percent CIs revealed that both groups significantly increased in weekly volume-load with large effect sizes (HL = 1.66, LL = 1.02). There were no between-group differences for change in volume-load though average weekly volume-load was significantly greater for LL (p < 0.001). Significant Pearson's correlations were found for the HL group between average weekly volume-load and both strength (r = 0.650, p = 0.005) and absolute endurance (r = 0.552, p = 0.022) increases. Strength and absolute endurance increases do not differ between HL and LL conditions in adolescents when performed to momentary concentric failure. Under HL conditions greater weekly volume-load is associated with greater strength and absolute endurance increases.

  9. Numerical simulation of volume-controlled mechanical ventilated respiratory system with 2 different lungs.

    PubMed

    Shi, Yan; Zhang, Bolun; Cai, Maolin; Zhang, Xiaohua Douglas

    2016-11-09

    Mechanical ventilation is a key therapy for patients who cannot breathe adequately by themselves, and dynamics of mechanical ventilation system is of great significance for life support of patients. Recently, models of mechanical ventilated respiratory system with 1 lung are used to simulate the respiratory system of patients. However, humans have 2 lungs. When the respiratory characteristics of 2 lungs are different, a single-lung model cannot reflect real respiratory system. In this paper, to illustrate dynamic characteristics of mechanical ventilated respiratory system with 2 different lungs, we propose a mathematical model of mechanical ventilated respiratory system with 2 different lungs and conduct experiments to verify the model. Furthermore, we study the dynamics of mechanical ventilated respiratory system with 2 different lungs. This research study can be used for improving the efficiency and safety of volume-controlled mechanical ventilation system.

  10. Status of and prospects for bronchoscopic lung volume reduction for patients with severe emphysema.

    PubMed

    Yu, Hang; Wang, Lijie; Wu, Zhen; Yang, Zhen

    2016-11-15

    Bronchoscopic lung volume reduction (BLVR) is a minimally invasive treatment for severe emphysema, providing treatment options for patients who are unable to undergo lung volume reduction surgery (LVRS) or lung transplantation. Current BLVR techniques include bronchoscopic volume reduction with valve implants, use of a lung volume reduction coil (LVRC), bronchoscopic thermal vapor ablation (BTVA), biological lung volume reduction (BioLVR), and use of airway bypass stents (ABS). To date, several randomized controlled trials of these bronchoscopic therapies have been conducted in patients with emphysema, and bronchoscopic volume reduction with valve implants remains the best approach thus far. Recent studies indicate that BLVR may be of great value in improving lung function, exercise capacity, and quality of life and that BLVR has the potential to replace conventional surgery for patients with severe emphysema. Optimal patient selection and the proper selection of the BLVR technique in accordance with patient characteristics are crucial to the success of BLVR. More multicenter, prospective, randomized controlled trials need to be conducted in the future to optimize the current selection strategy and evaluate the safety, efficiency, and long-term benefit of BLVR techniques.

  11. Linear dimensions and volumes of human lungs obtained from CT images.

    PubMed

    Kramer, Gary H; Capello, Kevin; Bearrs, Brock; Lauzon, Aimée; Normandeau, Lysanne

    2012-04-01

    This work provides the results of a collaboration between the Human Monitoring Laboratory (HML) and the Centre Hospitalier de l'Université de Montréal (CHUM) in which CHUM provided CT lung image sets from 166 patients for the analysis of linear dimensions and lung volume. This work has shown that a large amount of data exists in the medical community that can be of value to the health physics community. The intent of this study was to determine the range of linear dimensional parameters that could be used for torso phantom development for males and females; understand and characterize the variability of linear lung dimensions for males and females; replace the brief table in ICRP 23 with more modern data for males and females; identify an empirical formula that would predict linear dimensions of human lungs from age, height and/or weight for males and females; characterize the left, right, and total lung volumes of males and females in this data set; and compare the lung volumes of males and females to published equations for determining lung volumes. It was found that linear dimensions of lungs are essentially independent of age, height, and weight, so predictive equations cannot be formulated; however, the ranges of those parameters have now been established for the population studied herein. The data presented here are more modern than the brief table that appeared in ICRP 23, and the average values could be used as future guidelines. Whole lung volumes have been determined from the voxel lung phantoms, and empirical formulae have been developed for males and females in this data set; these compare favorably with the published values in ICRP 66.

  12. Automatic segmentation of tumor-laden lung volumes from the LIDC database

    NASA Astrophysics Data System (ADS)

    O'Dell, Walter G.

    2012-03-01

    The segmentation of the lung parenchyma is often a critical pre-processing step prior to application of computer-aided detection of lung nodules. Segmentation of the lung volume can dramatically decrease computation time and reduce the number of false positive detections by excluding from consideration extra-pulmonary tissue. However, while many algorithms are capable of adequately segmenting the healthy lung, none have been demonstrated to work reliably well on tumor-laden lungs. Of particular challenge is to preserve tumorous masses attached to the chest wall, mediastinum or major vessels. In this role, lung volume segmentation comprises an important computational step that can adversely affect the performance of the overall CAD algorithm. An automated lung volume segmentation algorithm has been developed with the goals to maximally exclude extra-pulmonary tissue while retaining all true nodules. The algorithm comprises a series of tasks including intensity thresholding, 2-D and 3-D morphological operations, 2-D and 3-D floodfilling, and snake-based clipping of nodules attached to the chest wall. It features the ability to (1) exclude trachea and bowels, (2) snip large attached nodules using snakes, (3) snip small attached nodules using dilation, (4) preserve large masses fully internal to lung volume, (5) account for basal aspects of the lung where in a 2-D slice the lower sections appear to be disconnected from main lung, and (6) achieve separation of the right and left hemi-lungs. The algorithm was developed and trained to on the first 100 datasets of the LIDC image database.

  13. Effect of various methods for rectum delineation on relative and absolute dose-volume histograms for prostate IMRT treatment planning

    SciTech Connect

    Kusumoto, Chiaki; Ohira, Shingo; Miyazaki, Masayoshi; Ueda, Yoshihiro; Isono, Masaru; Teshima, Teruki

    2016-07-01

    Several reports have dealt with correlations of late rectal toxicity with rectal dose-volume histograms (DVHs) for high dose levels. There are 2 techniques to assess rectal volume for reception of a specific dose: relative-DVH (R-DVH, %) that indicates relative volume for a vertical axis, and absolute-DVH (A-DVH, cc) with its vertical axis showing absolute volume of the rectum. The parameters of DVH vary depending on the rectum delineation method, but the literature does not present any standardization of such methods. The aim of the present study was to evaluate the effects of different delineation methods on rectal DVHs. The enrollment for this study comprised 28 patients with high-risk localized prostate cancer, who had undergone intensity-modulated radiation therapy (IMRT) with the prescription dose of 78 Gy. The rectum was contoured with 4 different methods using 2 lengths, short (Sh) and long (Lg), and 2 cross sections, rectum (Rec) and rectal wall (Rw). Sh means the length from 1 cm above the seminal vesicles to 1 cm below the prostate and Lg the length from the rectosigmoid junction to the anus. Rec represents the entire rectal volume including the rectal contents and Rw the rectal volume of the area with a wall thickness of 4 mm. We compared dose-volume parameters by using 4 rectal contour methods for the same plan with the R-DVHs as well as the A-DVHs. For the high dose levels, the R-DVH parameters varied widely. The mean of V{sub 70} for Sh-Rw was the highest (19.4%) and nearly twice as high as that for Lg-Rec (10.4%). On the contrary, only small variations were observed in the A-DVH parameters (4.3, 4.3, 5.5, and 5.5 cc for Sh-Rw, Lg-Rw, Sh-Rec, and Lg-Rec, respectively). As for R-DVHs, the parameters of V{sub 70} varied depending on the rectal lengths (Sh-Rec vs Lg-Rec: R = 0.76; Sh-Rw vs Lg-Rw: R = 0.85) and cross sections (Sh-Rec vs Sh-Rw: R = 0.49; Lg-Rec vs Lg-Rw: R = 0.65). For A-DVHs, however, the parameters of Sh rectal A-DVHs hardly changed

  14. A fundamental problem in determining functional residual capacity or residual volume. [of lungs

    NASA Technical Reports Server (NTRS)

    Boutellier, U.; Farhi, L. E.

    1986-01-01

    To measure a lung volume that is not directly accessible, one often follows dilution of a single-gas tracer, present initially only in the lung or in a rebreathing bag. The final volume available to the tracer is assumed to be the sum of the two initial components. Since O2 is taken up and CO2 is eliminated during the few breaths required for mixing, the total volume changes. The error in lung volume due to this volume change can exceed 10 pct. Theoretical and experimental data is presented to demonstrate the effect of CO2 and O2 exchange. A general equation, based on N2 and Ar, which allows one to circumvent the problems created by these fluxes is introduced. The pitfall of the back-extrapolation approach for a single tracer is shown.

  15. Endoscopic lung volume reduction effectively treats acute respiratory failure secondary to bullous emphysema.

    PubMed

    Sexton, Paul; Garrett, Jeffrey E; Rankin, Nigel; Anderson, Graeme

    2010-10-01

    Emphysema often affects the lungs in a heterogeneous fashion, and collapse or removal of severely hyperinflated portions of lung can improve overall lung function and symptoms. The role of lung volume reduction (LVR) surgery in selected patients is well established, but that of non-surgical LVR is still being defined. In particular, use of endobronchial LVR is still under development. This case report describes a 48-year-old non-smoker with severe bullous emphysema complicated by acute hypercapnic respiratory failure, who was successfully treated by endobronchial valve placement while intubated in an intensive care unit.

  16. The reflex effects of alterations in lung volume on systemic vascular resistance in the dog

    PubMed Central

    Daly, M. de Burgh; Hazzledine, Julie L.; Ungar, A.

    1967-01-01

    1. The reflex effects of alterations in lung volume on systemic vascular resistance have been studied in anaesthetized dogs under conditions in which the systemic circulation was perfused at constant blood flow. The pressures in the isolated perfused carotid sinuses and aortic arch, and the arterial blood PO2 and PCO2 were maintained constant. 2. A maintained inflation of the lungs produced by injection of air into the trachea caused a fall in systemic arterial perfusion pressure, indicating vasodilatation. The size of the systemic vasodilator response varied directly with the pressure and volume of gas used to inflate the lungs. A similar effect was observed when the tidal volume of lungs ventilated by an intermittent positive pressure was increased. 3. Collapse of the lungs by creating a pneumothorax in closed-chest spontaneously breathing animals evoked a systemic vasoconstrictor response which was reversed when the lungs were re-expanded. 4. These vasodilator responses were abolished by dividing the pulmonary branches of the thoracic vagosympathetic nerves. Evidence is presented that the afferent fibres run in the cervical vagosympathetic nerves and through the stellate ganglia. 5. The responses were unaffected by atropine, but were abolished by hexamethonium, guanethidine and by bretylium tosylate, indicating that they are mediated via the sympathetic nervous system. 6. Evidence is presented that the lungs are a constant course of afferent impulses inhibiting the `vasomotor centre', and that the lung inflation—systemic vasodilator reflex is a potential mechanism operating in eupnoeic breathing. PMID:6032204

  17. A rebreathing method for measuring lung volume, diffusing capacity and cardiac output in conscious small animals.

    PubMed

    Yilmaz, Cuneyt; Johnson, Robert L; Hsia, Connie C W

    2005-04-15

    We developed a multiple gas rebreathing technique for measuring lung diffusing capacity (DL(CO)), lung volume (V(L)) and cardiac output simultaneously in conscious spontaneously breathing small animals. Lung volume was measured from the dilution of methane (CH4) or sulfur hexafluoride (SF6) and verified independently by a helium washout technique. Cardiac output and DL(CO) were estimated from the uptake of acetylene and carbon monoxide, respectively. We tested guinea pigs at two levels of alveolar oxygen tension in order to estimate membrane diffusing capacity and pulmonary capillary blood volume by the Roughton-Forster technique. Results show that measured DL(CO) are consistent with reported values in anesthetized guinea pigs as well as with allometric comparison across species. Lung volume estimated from SF6 dilution agreed closely with that estimated independently from helium washout; however, lung volume estimated from CH4 dilution was systematically lower due to the addition of endogenously produced CH4 to the rebreathing system. We conclude that this technique can be used to measure resting lung function in conscious unsedated small animals.

  18. Regional volume changes in canine lungs suspended in air

    NASA Technical Reports Server (NTRS)

    Abbrecht, Peter H.; Kyle, Richard R.; Bryant, Howard J.; Feuerstein, Irwin

    1995-01-01

    The purpose of this study was to determine the effect of the absence of a pleural pressure gradient (simulating the presumed condition found in microgravity) upon regional expansion of the lung. We attempted to produce a uniform pressure over the surface of the lung by suspending excised lungs in air. Such studies should help determine whether or not the absence of a pleural pressure gradient leads to uniform ventilation. A preparation in which there is no pleural pressure gradient should also be useful in studying non-gravitational effects on ventilation distribution.

  19. Lung Volume and Continuous Positive Airway Pressure Requirements in Obstructive Sleep Apnea

    PubMed Central

    Heinzer, Raphael C.; Stanchina, Michael L.; Malhotra, Atul; Fogel, Robert B.; Patel, Sanjay R.; Jordan, Amy S.; Schory, Karen; White, David P.

    2005-01-01

    Previous studies have demonstrated that lung volume during wakefulness influences upper airway size and resistance, particularly in patients with sleep apnea. We sought to determine the influence of lung volume on the level of continuous positive airway pressure (CPAP) required to prevent flow limitation during non-REM sleep in subjects with sleep apnea. Seventeen subjects (apnea–hypopnea index, 42.6 ± 6.2 [SEM]) were studied during stable non-REM sleep in a rigid head-out shell equipped with a positive/negative pressure attachment for manipulation of extrathoracic pressure. An epiglottic pressure catheter plus a mask/pneumotachometer were used to assess flow limitation. When lung volume was increased by 1,035 ± 22 ml, the CPAP level could be decreased from 11.9 ± 0.7 to 4.8 ± 0.7 cm H2O (p < 0.001) without flow limitation. The decreased CPAP at the same negative extrathoracic pressure yielded a final lung volume increase of 421 ± 36 ml above the initial value. Conversely, when lung volume was reduced by 732 ± 74 ml (n = 8), the CPAP level had to be increased from 11.9 ± 0.7 to 17.1 ± 1.0 cm H2O (p < 0.001) to prevent flow limitation, with a final lung volume decrease of 567 ± 78 ml. These results demonstrate that relatively small changes in lung volume have an important effect on the upper airway in subjects with sleep apnea during non-REM sleep. PMID:15817803

  20. A comparison of conventional surfactant treatment and partial liquid ventilation on the lung volume of injured ventilated small lungs.

    PubMed

    Proquitté, Hans; Hartenstein, Sebastian; Koelsch, Uwe; Wauer, Roland R; Rüdiger, Mario; Schmalisch, Gerd

    2013-08-01

    As an alternative to surfactant therapy (ST), partial liquid ventilation (PLV) with perfluorocarbons (PFC) has been considered as a treatment for acute lung injury (ALI) in newborns. The instilled PFC is much heavier than the instilled surfactant and the aim of this study was to investigate whether PLV, compared to ST, increases the end-expiratory volume of the lung (VL). Fifteen newborn piglets (age <12 h, mean weight 678 g) underwent saline lung lavage to achieve a surfactant depletion. Thereafter animals were randomized to PLV (n = 8), receiving PFC PF5080 (3M, Germany) at 30 mL kg(-1), and ST (n = 7) receiving 120 mg Curosurf®. Blood gases, hemodynamics and static compliance were measured initially (baseline), immediately after ALI, and after 240 min mechanical ventilation with either technique. Subsequently all piglets were killed; the lungs were removed in toto and frozen in liquid N2. After freeze-drying the lungs were cut into lung cubes (LCs) with edge lengths of 0.7 cm, to calculate VL. All LCs were weighed and the density of the dried lung tissue was calculated. No statistically significant differences between treatment groups PLV and ST (means ± SD) were noted in body weight (676 ± 16 g versus 679 ± 17 g; P = 0.974) or lung dry weight (1.64 ± 0.29 g versus 1.79 ± 0.48 g; P = 0.48). Oxygenation index and ventilatory efficacy index did not differ significantly between both groups at any time. VL (34.28 ± 6.13 mL versus 26.22 ± 8.1 mL; P < 0.05) and the density of the dried lung tissue (48.07 ± 5.02 mg mL(-1) versus 69.07 ± 5.30 mg mL(-1); P < 0.001), however, differed significantly between the PLV and ST groups. A 4 h PLV treatment of injured ventilated small lungs increased VL by 30% and decreased lung density by 31% compared to ST treatment, indicating greater lung distension after PLV compared to ST.

  1. Easy Absolute Values? Absolutely

    ERIC Educational Resources Information Center

    Taylor, Sharon E.; Mittag, Kathleen Cage

    2015-01-01

    The authors teach a problem-solving course for preservice middle-grades education majors that includes concepts dealing with absolute-value computations, equations, and inequalities. Many of these students like mathematics and plan to teach it, so they are adept at symbolic manipulations. Getting them to think differently about a concept that they…

  2. Volume versus diameter assessment of small pulmonary nodules in CT lung cancer screening

    PubMed Central

    Han, Daiwei; Oudkerk, Matthijs

    2017-01-01

    Currently, lung cancer screening by low-dose chest CT is implemented in the United States for high-risk persons. A disadvantage of lung cancer screening is the large number of small-to-intermediate sized lung nodules, detected in around 50% of all participants, the large majority being benign. Accurate estimation of nodule size and growth is essential in the classification of lung nodules. Currently, manual diameter measurements are the standard for lung cancer screening programs and routine clinical care. However, European screening studies using semi-automated volume measurements have shown higher accuracy and reproducibility compared to diameter measurements. In addition to this, with the optimization of CT scan techniques and reconstruction parameters, as well as advances in segmentation software, the accuracy of nodule volume measurement can be improved even further. The positive results of previous studies on volume and diameter measurements of lung nodules suggest that manual measurements of nodule diameter may be replaced by semi-automated volume measurements in the (near) future. PMID:28331824

  3. Development and proof-of-concept of three-dimensional lung histology volumes

    NASA Astrophysics Data System (ADS)

    Mathew, Lindsay; Alabousi, Mostafa; Wheatley, Andrew; Aladl, Usaf; Slipetz, Deborah; Hogg, James C.; Fenster, Aaron; Parraga, Grace

    2012-03-01

    Most medical imaging is inherently three-dimensional (3D) but for validation of pathological findings, histopathology is commonly used and typically histopathology images are acquired as twodimensional slices with quantitative analysis performed in a single dimension. Histopathology is invasive, labour-intensive, and the analysis cannot be performed in real time, yet it remains the gold standard for the pathological diagnosis and validation of clinical or radiological diagnoses of disease. A major goal worldwide is to improve medical imaging resolution, sensitivity and specificity to better guide therapy and biopsy and to one day delay or replace biopsy. A key limitation however is the lack of tools to directly compare 3D macroscopic imaging acquired in patients with histopathology findings, typically provided in a single dimension (1D) or in two dimensions (2D). To directly address this, we developed methods for 2D histology slice visualization/registration to generate 3D volumes and quantified tissue components in the 3D volume for direct comparison to volumetric micro-CT and clinical CT. We used the elastase-instilled mouse emphysema lung model to evaluate our methods with murine lungs sectioned (5 μm thickness/10 μm gap) and digitized with 2μm in-plane resolution. 3D volumes were generated for wildtype and elastase mouse lung sections after semi-automated registration of all tissue slices. The 1D mean linear intercept (Lm) for wildtype (WT) (47.1 μm +/- 9.8 μm) and elastase mouse lung (64.5 μm +/- 14.0 μm) was significantly different (p<.001). We also generated 3D measurements based on tissue and airspace morphometry from the 3D volumes and all of these were significantly different (p<.0001) when comparing elastase and WT mouse lung. The ratio of the airspace-to-lung volume for the entire lung volume was also significantly and strongly correlated with Lm.

  4. Longitudinal micro-CT provides biomarkers of lung disease that can be used to assess the effect of therapy in preclinical mouse models, and reveal compensatory changes in lung volume.

    PubMed

    Vande Velde, Greetje; Poelmans, Jennifer; De Langhe, Ellen; Hillen, Amy; Vanoirbeek, Jeroen; Himmelreich, Uwe; Lories, Rik J

    2016-01-01

    In vivo lung micro-computed tomography (micro-CT) is being increasingly embraced in pulmonary research because it provides longitudinal information on dynamic disease processes in a field in which ex vivo assessment of experimental disease models is still the gold standard. To optimize the quantitative monitoring of progression and therapy of lung diseases, we evaluated longitudinal changes in four different micro-CT-derived biomarkers [aerated lung volume, lung tissue (including lesions) volume, total lung volume and mean lung density], describing normal development, lung infections, inflammation, fibrosis and therapy. Free-breathing mice underwent micro-CT before and repeatedly after induction of lung disease (bleomycin-induced fibrosis, invasive pulmonary aspergillosis, pulmonary cryptococcosis) and therapy (imatinib). The four lung biomarkers were quantified. After the last time point, we performed pulmonary function tests and isolated the lungs for histology. None of the biomarkers remained stable during longitudinal follow-up of adult healthy mouse lungs, implying that biomarkers should be compared with age-matched controls upon intervention. Early inflammation and progressive fibrosis led to a substantial increase in total lung volume, which affects the interpretation of aerated lung volume, tissue volume and mean lung density measures. Upon treatment of fibrotic lung disease, the improvement in aerated lung volume and function was not accompanied by a normalization of the increased total lung volume. Significantly enlarged lungs were also present in models of rapidly and slowly progressing lung infections. The data suggest that total lung volume changes could partly reflect a compensatory mechanism that occurs during disease progression in mice. Our findings underscore the importance of quantifying total lung volume in addition to aerated lung or lesion volumes to accurately document growth and potential compensatory mechanisms in mouse models of lung

  5. The lung volume reduction coil for the treatment of emphysema: a new therapy in development.

    PubMed

    Klooster, Karin; Ten Hacken, Nick H T; Slebos, Dirk-Jan

    2014-09-01

    Lung volume reduction (LVR) coil treatment is a novel therapy for patients with severe emphysema. In this bilateral bronchoscopic treatment, approximately 10 LVR coils per lobe are delivered under fluoroscopic guidance in two sequential procedures. The LVR coil reduces lung volume by compressing the most destructed areas of the lung parenchyma and restores the lung elastic recoil. Both patients with upper- and lower-lobe predominant emphysema as well as a homogeneous emphysema distribution can be treated. LVR coil treatment results in an improvement of pulmonary function, exercise tolerance and quality of life. The LVR-coil treatment has been evaluated in several European clinical trials since 2008 and received CE mark approval in 2010. Currently, two large multicenter randomized controlled trials are underway in Europe and North America to assess the efficacy and safety of the LVR-coil treatment at 12 months compared with usual care. In this review, we share our experience with the LVR-coil treatment.

  6. Reduction of Pulmonary Function After Surgical Lung Resections of Different Volume

    PubMed Central

    Cukic, Vesna

    2014-01-01

    Introduction: In recent years an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused with common etiologic factor - smoking cigarettes. Objective: To determine how big the loss of lung function is after surgical resection of lung of different range. Methods: The study was done on 58 patients operated at the Clinic for thoracic surgery KCU Sarajevo, previously treated at the Clinic for pulmonary diseases “Podhrastovi” in the period from 01.06.2012. to 01.06.2014. The following resections were done: pulmectomy (left, right), lobectomy (upper, lower: left and right). The values of postoperative pulmonary function were compared with preoperative ones. As a parameter of lung function we used FEV1 (forced expiratory volume in one second), and changes in FEV1 are expressed in liters and in percentage of the recorded preoperative and normal values of FEV1. Measurements of lung function were performed seven days before and 2 months after surgery. Results: Postoperative FEV1 was decreased compared to preoperative values. After pulmectomy the maximum reduction of FEV1 was 44%, and after lobectomy it was 22% of the preoperative values. Conclusion: Patients with airway obstruction are limited in their daily life before the surgery, and an additional loss of lung tissue after resection contributes to their inability. Potential benefits of lung resection surgery should be balanced in relation to postoperative morbidity and mortality. PMID:25568542

  7. Entropy Production and the Pressure-Volume Curve of the Lung.

    PubMed

    Oliveira, Cláudio L N; Araújo, Ascânio D; Bates, Jason H T; Andrade, José S; Suki, Béla

    2016-01-01

    We investigate analytically the production of entropy during a breathing cycle in healthy and diseased lungs. First, we calculate entropy production in healthy lungs by applying the laws of thermodynamics to the well-known transpulmonary pressure-volume (P-V) curves of the lung under the assumption that lung tissue behaves as an entropic spring similar to rubber. The bulk modulus, B, of the lung is also derived from these calculations. Second, we extend this approach to elastic recoil disorders of the lung such as occur in pulmonary fibrosis and emphysema. These diseases are characterized by particular alterations in the P-V relationship. For example, in fibrotic lungs B increases monotonically with disease progression, while in emphysema the opposite occurs. These diseases can thus be mimicked simply by making appropriate adjustments to the parameters of the P-V curve. Using Clausius's formalism, we show that entropy production, ΔS, is related to the hysteresis area, ΔA, enclosed by the P-V curve during a breathing cycle, namely, ΔS=ΔA∕T, where T is the body temperature. Although ΔA is highly dependent on the disease, such formula applies to healthy as well as diseased lungs, regardless of the disease stage. Finally, we use an ansatz to predict analytically the entropy produced by the fibrotic and emphysematous lungs.

  8. Entropy Production and the Pressure–Volume Curve of the Lung

    PubMed Central

    Oliveira, Cláudio L. N.; Araújo, Ascânio D.; Bates, Jason H. T.; Andrade, José S.; Suki, Béla

    2016-01-01

    We investigate analytically the production of entropy during a breathing cycle in healthy and diseased lungs. First, we calculate entropy production in healthy lungs by applying the laws of thermodynamics to the well-known transpulmonary pressure–volume (P–V) curves of the lung under the assumption that lung tissue behaves as an entropic spring similar to rubber. The bulk modulus, B, of the lung is also derived from these calculations. Second, we extend this approach to elastic recoil disorders of the lung such as occur in pulmonary fibrosis and emphysema. These diseases are characterized by particular alterations in the P–V relationship. For example, in fibrotic lungs B increases monotonically with disease progression, while in emphysema the opposite occurs. These diseases can thus be mimicked simply by making appropriate adjustments to the parameters of the P–V curve. Using Clausius's formalism, we show that entropy production, ΔS, is related to the hysteresis area, ΔA, enclosed by the P–V curve during a breathing cycle, namely, ΔS=ΔA∕T, where T is the body temperature. Although ΔA is highly dependent on the disease, such formula applies to healthy as well as diseased lungs, regardless of the disease stage. Finally, we use an ansatz to predict analytically the entropy produced by the fibrotic and emphysematous lungs. PMID:26973540

  9. Characterization of the Branching Structure of the Lung from ''Macroscopic'' Pressure-Volume Measurements

    SciTech Connect

    Majumdar, A.; Alencar, A. M.; Buldyrev, S. V.; Hantos, Z.; Stanley, H. E.; Suki, B.

    2001-07-30

    We analyze the problem of fluid flow in a bifurcating structure containing random blockages that can be removed by fluid pressure. We introduce an asymmetric tree model and find that the predicted pressure-volume relation is connected to the distribution {Pi}(n) of the generation number n of the tree's terminal segments. We use this relation to explore the branching structure of the lung by analyzing experimental pressure-volume data from dog lungs. The {Pi}(n) extracted from the data using the model agrees well with experimental data on the branching structure. We can thus obtain information about the asymmetric structure of the lung from macroscopic, noninvasive pressure-volume measurements.

  10. Fractional rate of change of swim-bladder volume is reliably related to absolute depth during vertical displacements in teleost fish.

    PubMed

    Taylor, Graham K; Holbrook, Robert Iain; de Perera, Theresa Burt

    2010-09-06

    Fish must orient in three dimensions as they navigate through space, but it is unknown whether they are assisted by a sense of depth. In principle, depth can be estimated directly from hydrostatic pressure, but although teleost fish are exquisitely sensitive to changes in pressure, they appear unable to measure absolute pressure. Teleosts sense changes in pressure via changes in the volume of their gas-filled swim-bladder, but because the amount of gas it contains is varied to regulate buoyancy, this cannot act as a long-term steady reference for inferring absolute pressure. In consequence, it is generally thought that teleosts are unable to sense depth using hydrostatic pressure. Here, we overturn this received wisdom by showing from a theoretical physical perspective that absolute depth could be estimated during fast, steady vertical displacements by combining a measurement of vertical speed with a measurement of the fractional rate of change of swim-bladder volume. This mechanism works even if the amount of gas in the swim-bladder varies, provided that this variation occurs over much longer time scales than changes in volume during displacements. There is therefore no a priori physical justification for assuming that teleost fish cannot sense absolute depth by using hydrostatic pressure cues.

  11. Relationship between costovertebral joint kinematics and lung volume in supine humans.

    PubMed

    Beyer, Benoît; Van Sint Jan, Serge; Chèze, Laurence; Sholukha, Victor; Feipel, Véronique

    2016-10-01

    This study investigates the relationship between the motion of the first ten costovertebral joints (CVJ) and lung volume over the inspiratory capacity (IC) using detailed kinematic analysis in a sample of 12 asymptomatic subjects. Retrospective codified spiral-CT data obtained at total lung capacity (TLC), middle of inspiratory capacity (MIC) and at functional residual capacity (FRC) were analysed. CVJ 3D kinematics were processed using previously-published methods. We tested the influence of the side, CVJ level and lung volume on CVJ kinematics. In addition, the correlations between anthropologic/pulmonary variables and CVJ kinematics were analysed. No linear correlation was found between lung volumes and CVJ kinematics. Major findings concerning 3D kinematics can be summarized as follows: 1) Ranges-of-motion decrease gradually with increasing CVJ level; 2) rib displacements are significantly reduced at lung volumes above the MIC and do not differ between CVJ levels; 3) the axes of rotation of the ribs are similarly oriented for all CVJ levels.

  12. Effect of prolonged bed rest on lung volume in normal individuals

    NASA Technical Reports Server (NTRS)

    Beckett, W. S.; Vroman, N. B.; Nigro, D.; Thompson-Gorman, S.; Wilkerson, J. E.

    1986-01-01

    The effect of prolonged bed rest on the lung function was studied by measuring forced vital capacity (FVC) and total lung capacity (TLC) in normal subjects before, during, and after 11- to 12-day rest periods. It was found that both FVC and TLC increased during bed rest (compared with the ambulatory controls), while residual volume and functional residual capacity of the respiratory system did not change. It is concluded that the increase in TLC by prolonged bed rest is not dependent on alterations in plasma volume.

  13. 4-D segmentation and normalization of 3He MR images for intrasubject assessment of ventilated lung volumes

    NASA Astrophysics Data System (ADS)

    Contrella, Benjamin; Tustison, Nicholas J.; Altes, Talissa A.; Avants, Brian B.; Mugler, John P., III; de Lange, Eduard E.

    2012-03-01

    Although 3He MRI permits compelling visualization of the pulmonary air spaces, quantitation of absolute ventilation is difficult due to confounds such as field inhomogeneity and relative intensity differences between image acquisition; the latter complicating longitudinal investigations of ventilation variation with respiratory alterations. To address these potential difficulties, we present a 4-D segmentation and normalization approach for intra-subject quantitative analysis of lung hyperpolarized 3He MRI. After normalization, which combines bias correction and relative intensity scaling between longitudinal data, partitioning of the lung volume time series is performed by iterating between modeling of the combined intensity histogram as a Gaussian mixture model and modulating the spatial heterogeneity tissue class assignments through Markov random field modeling. Evaluation of the algorithm was retrospectively applied to a cohort of 10 asthmatics between 19-25 years old in which spirometry and 3He MR ventilation images were acquired both before and after respiratory exacerbation by a bronchoconstricting agent (methacholine). Acquisition was repeated under the same conditions from 7 to 467 days (mean +/- standard deviation: 185 +/- 37.2) later. Several techniques were evaluated for matching intensities between the pre and post-methacholine images with the 95th percentile value histogram matching demonstrating superior correlations with spirometry measures. Subsequent analysis evaluated segmentation parameters for assessing ventilation change in this cohort. Current findings also support previous research that areas of poor ventilation in response to bronchoconstriction are relatively consistent over time.

  14. Mechanisms of gas exchange response to lung volume reduction surgery in severe emphysema.

    PubMed

    Cremona, George; Barberà, Joan A; Barbara, Joan A; Melgosa, Teresa; Appendini, Lorenzo; Roca, Josep; Casadio, Caterina; Donner, Claudio F; Rodriguez-Roisin, Roberto; Wagner, Peter D

    2011-04-01

    Lung volume reduction surgery (LVRS) improves lung function, respiratory symptoms, and exercise tolerance in selected patients with chronic obstructive pulmonary disease, who have heterogeneous emphysema. However, the reported effects of LVRS on gas exchange are variable, even when lung function is improved. To clarify how LVRS affects gas exchange in chronic obstructive pulmonary disease, 23 patients were studied before LVRS, 14 of whom were again studied afterwards. We performed measurements of lung mechanics, pulmonary hemodynamics, and ventilation-perfusion (Va/Q) inequality using the multiple inert-gas elimination technique. LVRS improved arterial Po₂ (Pa(O₂)) by a mean of 6 Torr (P = 0.04), with no significant effect on arterial Pco₂ (Pa(CO₂)), but with great variability in both. Lung mechanical properties improved considerably more than did gas exchange. Post-LVRS Pa(O₂) depended mostly on its pre-LVRS value, whereas improvement in Pa(O(2)) was explained mostly by improved Va/Q inequality, with lesser contributions from both increased ventilation and higher mixed venous Po(2). However, no index of lung mechanical properties correlated with Pa(O₂). Conversely, post-LVRS Pa(CO₂) bore no relationship to its pre-LVRS value, whereas changes in Pa(CO₂) were tightly related (r² = 0.96) to variables, reflecting decrease in static lung hyperinflation (intrinsic positive end-expiratory pressure and residual volume/total lung capacity) and increase in airflow potential (tidal volume and maximal inspiratory pressure), but not to Va/Q distribution changes. Individual gas exchange responses to LVRS vary greatly, but can be explained by changes in combinations of determining variables that are different for oxygen and carbon dioxide.

  15. Lung volume assessment for a cross-comparison of two breathing-adapted techniques in radiotherapy

    SciTech Connect

    Simon, Luc . E-mail: luc.simon@curie.net; Giraud, Philippe; Servois, Vincent; Rosenwald, Jean-Claude

    2005-10-01

    Purpose: To assess the validity of gated radiotherapy of lung by using a cross-check methodology based on four-dimensional (4D)-computed tomography (CT) exams. Variations of volume of a breathing phantom was used as an indicator. Methods and Materials: A balloon was periodically inflated and deflated by a medical ventilator. The volume variation ({delta}V) of the balloon was measured simultaneously by a spirometer, taken as reference, and by contouring 4D-CT series (10 phases) acquired by the real-time position management system (RPM). Similar cross-comparison was performed for 2 lung patients, 1 with free breathing (FB), the other with deep-inspiration breath-hold (DIBH) technique. Results: During FB, {delta}V measured by the spirometer and from 4D-CT were in good agreement: the mean differences for all phases were 8.1 mL for the balloon and 10.5 mL for a patient-test. End-inspiration lung volume has been shown to be slightly underestimated by the 4D-CT. The discrepancy for {delta}V between DIBH and end-expiration, measured from CT and from spirometer, respectively, was less than 3%. Conclusions: Provided that each slice series is correctly associated with the proper breathing phase, 4D-CT allows an accurate assessment of lung volume during the whole breathing cycle ({delta}V error <3% compared with the spirometer signal). Taking the lung volume variation into account is a central issue in the evaluation and control of the toxicity for lung radiation treatments.

  16. Predicting Structure-Function Relations and Survival following Surgical and Bronchoscopic Lung Volume Reduction Treatment of Emphysema

    PubMed Central

    Mondoñedo, Jarred R.

    2017-01-01

    Lung volume reduction surgery (LVRS) and bronchoscopic lung volume reduction (bLVR) are palliative treatments aimed at reducing hyperinflation in advanced emphysema. Previous work has evaluated functional improvements and survival advantage for these techniques, although their effects on the micromechanical environment in the lung have yet to be determined. Here, we introduce a computational model to simulate a force-based destruction of elastic networks representing emphysema progression, which we use to track the response to lung volume reduction via LVRS and bLVR. We find that (1) LVRS efficacy can be predicted based on pre-surgical network structure; (2) macroscopic functional improvements following bLVR are related to microscopic changes in mechanical force heterogeneity; and (3) both techniques improve aspects of survival and quality of life influenced by lung compliance, albeit while accelerating disease progression. Our model predictions yield unique insights into the microscopic origins underlying emphysema progression before and after lung volume reduction. PMID:28182686

  17. Predicting Structure-Function Relations and Survival following Surgical and Bronchoscopic Lung Volume Reduction Treatment of Emphysema.

    PubMed

    Mondoñedo, Jarred R; Suki, Béla

    2017-02-01

    Lung volume reduction surgery (LVRS) and bronchoscopic lung volume reduction (bLVR) are palliative treatments aimed at reducing hyperinflation in advanced emphysema. Previous work has evaluated functional improvements and survival advantage for these techniques, although their effects on the micromechanical environment in the lung have yet to be determined. Here, we introduce a computational model to simulate a force-based destruction of elastic networks representing emphysema progression, which we use to track the response to lung volume reduction via LVRS and bLVR. We find that (1) LVRS efficacy can be predicted based on pre-surgical network structure; (2) macroscopic functional improvements following bLVR are related to microscopic changes in mechanical force heterogeneity; and (3) both techniques improve aspects of survival and quality of life influenced by lung compliance, albeit while accelerating disease progression. Our model predictions yield unique insights into the microscopic origins underlying emphysema progression before and after lung volume reduction.

  18. Lung Volume Reduction Coils as a Novel Bronchoscopic Treatment for Emphysema

    PubMed Central

    Connolly, Timothy A.

    2016-01-01

    Chronic obstructive pulmonary disease remains a major cause of morbidity and mortality worldwide. Despite regular advances in pharmacology, there remains great potential for addressing structural deficiencies, especially in emphysema. The loss of alveolar attachments to small bronchial tubes results in diffuse loss of elastic recoil and airway collapse during exhalation. This appears physiologically as hyperinflation of lung volumes with flattened diaphragms and significantly elevated residual volumes (RV) on pulmonary function testing (predicted RV > 175%). PMID:28298960

  19. Can virtual simulation of breast tangential portals accurately predict lung and heart volumes?

    PubMed

    Cooke, Stacey; Rattray, Greg

    2003-03-01

    A treatment portal or simulator image has traditionally been used to demonstrate the lung and heart coverage of the breast tangential portal. In many cases, these images were acquired as a planning session on the linear accelerator. The patients were also CT scanned to assess the lung/heart volume and to determine the surgical site depth for the electron-boost energy. A study using 50 consecutive patients was performed comparing the digitally reconstructed radiograph (DRR) from the virtual simulation with treatment portal images. Modification to the patient's arm position is required when performing the planning CT scans due to the aperture size of the CT scanner. Virtual simulation was used to assess the potential variation of lung and heart measurements. The average difference in lung volume between the DRR and portal image was less than 2 mm, with a range of 0-5 mm. Arm position did not have a significant impact on field deviation; however, great care was taken to minimize any changes in arm position. The modification of the arm position for CT scanning did not lead to significant variations between the DRRs and portal images. The Advantage Sim software has proven capable of producing good quality DRR images, providing a realistic representation of the lung and heart volume included in the treatment portal.

  20. Normal expiratory flow rate and lung volumes in patients with combined emphysema and interstitial lung disease: a case series and literature review.

    PubMed

    Heathcote, Karen L; Cockcroft, Donald W; Fladeland, Derek A; Fenton, Mark E

    2011-01-01

    Pulmonary function tests in patients with idiopathic pulmonary fibrosis characteristically show a restrictive pattern including small lung volumes and increased expiratory flow rates resulting from a reduction in pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. When the diseases coexist, pulmonary volumes are compensated, and a smaller than expected reduction or even normal lung volumes can be found. The present report describes 10 patients with progressive breathlessness, three of whom experienced severe limitation in their quality of life. All patients showed lung interstitial involvement and emphysema on computed tomography scan of the chest. The 10 patients showed normal spirometry and lung volumes with severe compromise of gas exchange. Normal lung volumes do not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.

  1. [Measurement of air leak volume after lung surgery using web-camera].

    PubMed

    Onuki, Takamasa; Matsumoto, T

    2005-05-01

    Persistent air leak from the lung is one of the major complications after lung operations, especially in the latest thoracic surgery, where a shorter hospital stay tends to be necessary. However, air leak volume has been rarely measured clinically because accustomed tools of gas flow meter were types which needed contact measure, and those were unstable in long-term use and high cost. We tried to measure air leak volume as follows: (1) Bubble was made in the water seal part of a drain bag. (2) The movement of bubbles was recorded with a web-camera. (3) The data from the movie was analyzed by Linux computer on-line. We believe this method is clinically applicable as a routine work after lung surgery because of non-contact type of measurements, its stableness in long-term, easiness to be handled, and reasonable in cost.

  2. Measurement of absolute cell volume, osmotic membrane water permeability, and refractive index of transmembrane water and solute flux by digital holographic microscopy

    NASA Astrophysics Data System (ADS)

    Boss, Daniel; Kühn, Jonas; Jourdain, Pascal; Depeursinge, Christian; Magistretti, Pierre J.; Marquet, Pierre

    2013-03-01

    A dual-wavelength digital holographic microscope to measure absolute volume of living cells is proposed. The optical setup allows us to reconstruct two quantitative phase contrast images at two different wavelengths from a single hologram acquisition. When adding the absorbing dye fast green FCF as a dispersive agent to the extracellular medium, cellular thickness can be univocally determined in the full field of view. In addition to the absolute cell volume, the method can be applied to derive important biophysical parameters of living cells including osmotic membrane water permeability coefficient and the integral intracellular refractive index (RI). Further, the RI of transmembrane flux can be determined giving an indication about the nature of transported solutes. The proposed method is applied to cultured human embryonic kidney cells, Chinese hamster ovary cells, human red blood cells, mouse cortical astrocytes, and neurons.

  3. Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants.

    PubMed

    Schibler, A; Hall, G L; Businger, F; Reinmann, B; Wildhaber, J H; Cernelc, M; Frey, U

    2002-10-01

    Small airway disease in infants is characterised by abnormal lung volume and uneven ventilation distribution. An inert tracer gas washin/washout technique using a pulsed ultrasonic flow meter is presented to measure functional residual capacity (FRC) and ventilation distribution in spontaneously breathing and unsedated infants. With a pulsed ultrasound sent through the main stream of the flow meter, flow, volume and MM of the breathing gas can be calculated. Sulphur hexafluoride was used as a tracer gas. In a mechanical lung model (volume range 53-188 mL) and in 12 healthy infants (aged 38.3+/-9.2 days; mean+/-SD) accuracy and reproducibility of the technique was assessed. Indices of ventilation distribution such as alveolar-based mean dilution number (AMDN) and pulmonary clearance delay (PCD) were calculated. Mean error of volume measurement in the lung model was 0.58% (coefficient of variance (CV) 1.3%). FRC was in the low predicted range for normal infants (18.0+/-2.0 mL x kg(-1)) and highly reproducible (5.5+/-1.7% intra-subject CV). AMDN was 1.63+/-0.15 and PCD was 52.9+/-11.1%. Measurement of functional residual capacity and ventilation distribution using a sulphur hexafluoride washin/washout and an ultrasonic flow meter proved to be highly accurate and reproducible in a lung model and in healthy, spontaneously breathing and unsedated infants.

  4. Knowledge-based automated technique for measuring total lung volume from CT

    NASA Astrophysics Data System (ADS)

    Brown, Matthew S.; McNitt-Gray, Michael F.; Mankovich, Nicholas J.; Goldin, Jonathan G.; Aberle, Denise R.

    1996-04-01

    A robust, automated technique has been developed for estimating total lung volumes from chest computed tomography (CT) images. The technique includes a method for segmenting major chest anatomy. A knowledge-based approach automates the calculation of separate volumes of the whole thorax, lungs, and central tracheo-bronchial tree from volumetric CT data sets. A simple, explicit 3D model describes properties such as shape, topology and X-ray attenuation, of the relevant anatomy, which constrain the segmentation of these anatomic structures. Total lung volume is estimated as the sum of the right and left lungs and excludes the central airways. The method requires no operator intervention. In preliminary testing, the system was applied to image data from two healthy subjects and four patients with emphysema who underwent both helical CT and pulmonary function tests. To obtain single breath-hold scans, the healthy subjects were scanned with a collimation of 5 mm and a pitch of 1.5, while the emphysema patients were scanned with collimation of 10 mm at a pitch of 2.0. CT data were reconstructed as contiguous image sets. Automatically calculated volumes were consistent with body plethysmography results (< 10% difference).

  5. The measurement of lung volumes using body plethysmography and helium dilution methods in COPD patients: a correlation and diagnosis analysis

    PubMed Central

    Tang, Yongjiang; Zhang, Mingke; Feng, Yulin; Liang, Binmiao

    2016-01-01

    Chronic obstructive pulmonary disease (COPD) is a chronic airway disease characterized by persistent airflow limitation. Moreover, lung hyperinflation evaluated by lung volumes is also the key pathophysiologic process during COPD progression. Nevertheless, there is still no preferred method to evaluate lung volumes. For this study, we recruited 170 patients with stable COPD to assess lung volumes stratified by airflow limitation severity. Lung volumes including residual volume (RV) and total lung capacity (TLC) were determined by both body plethysmography and helium dilution methods. The discrepancies between these two methods were recorded as ΔRV%pred, ΔTLC%pred, and ΔRV/TLC. We found that ΔRV%pred, ΔTLC%pred, and ΔRV/TLC increased significantly with the severity of COPD. The differences of lung capacity between these two methods were negatively correlated with FEV1%pred, and diffusing capacity for carbon monoxide (DLCO%pred). Moreover, the receiver operating characteristic (ROC) for ΔTLC%pred to distinguish severe COPD from non-severe COPD had an area under curve (AUC) of 0.886. The differences of lung volume parameters measured by body plethysmography and helium dilution methods were associated with airflow limitation and can effectively differentiate COPD severity, which may be a supportive method to assess the lung function of stable COPD patients. PMID:27876834

  6. Lung Ultrasound in the Management of Fluid Volume in Dialysis Patients: Potential Usefulness.

    PubMed

    Zoccali, Carmine

    2017-01-01

    Volume overload is a hidden, pervasive complication in dialysis patients with dyspnea and pulmonary edema being its main clinical manifestations. Measuring lung water has clinical potential because it allows timely treatment of lung congestion at a preclinical stage. Chest ultrasound (US) is a novel, well-validated technique that allows reliable estimates of lung water in clinical practice. The application of this technique in dialysis patients has shown that an unsuspectedly high proportion of these patients have moderate to severe lung congestion which is usually asymptomatic. Furthermore, lung congestion in these patients is only loosely associated with fluid excess as measured by bioimpedance (BIA). Lung congestion is associated with a high death risk in dialysis patients and therefore represents a potential treatment target. The "Lung water by Ultra-Sound guided Treatment to prevent death and cardiovascular complications in high risk ESRD patients with cardiomyopathy" (LUST) study will provide important information about the clinical value of this technique in the care of hemodialysis patients at high cardiovascular risk.

  7. Lung volumes and airway resistance in patients with a possible restrictive pattern on spirometry

    PubMed Central

    Schultz, Kenia; D'Aquino, Luiz Carlos; Soares, Maria Raquel; Gimenez, Andrea; Pereira, Carlos Alberto de Castro

    2016-01-01

    ABSTRACT Objective: Many patients with proportional reductions in FVC and FEV1 on spirometry show no reduction in TLC. The aim of this study was to evaluate the role that measuring lung volumes and airway resistance plays in the correct classification of patients with a possible restrictive pattern on spirometry. Methods: This was a prospective study involving adults with reduced FVC and FEV1, as well as an FEV1/FV(C) ratio within the predicted range. Restrictive lung disease (RLD) was characterized by TLC below the 5th percentile, as determined by plethysmography. Obstructive lung disease (OLD) was characterized by high specific airway resistance, significant changes in post-bronchodilator FEV1, or an FEF25-75% < 50% of predicted, together with a high RV/TLC ratio. Nonspecific lung disease (NLD) was characterized by TLC within the predicted range and no obstruction. Combined lung disease (CLD) was characterized by reduced TLC and findings indicative of airflow obstruction. Clinical diagnoses were based on clinical suspicion, a respiratory questionnaire, and the review of tests of interest. Results: We included 300 patients in the study, of whom 108 (36%) were diagnosed with RLD. In addition, 120 (40%) and 72 (24%) were diagnosed with OLD/CLD and NLD, respectively. Among the latter, 24 (33%) were clinically diagnosed with OLD. In this sample, 151 patients (50.3%) were obese, and obesity was associated with all patterns of lung disease. Conclusions: Measuring lung volumes and airway resistance is often necessary in order to provide an appropriate characterization of the pattern of lung disease in patients presenting with a spirometry pattern suggestive of restriction. Airflow obstruction is common in such cases. PMID:27812633

  8. Monte Carlo calculated doses to treatment volumes and organs at risk for permanent implant lung brachytherapy

    NASA Astrophysics Data System (ADS)

    Sutherland, J. G. H.; Furutani, K. M.; Thomson, R. M.

    2013-10-01

    Iodine-125 (125I) and Caesium-131 (131Cs) brachytherapy have been used with sublobar resection to treat stage I non-small cell lung cancer and other radionuclides, 169Yb and 103Pd, are considered for these treatments. This work investigates the dosimetry of permanent implant lung brachytherapy for a range of source energies and various implant sites in the lung. Monte Carlo calculated doses are calculated in a patient CT-derived computational phantom using the EGsnrc user-code BrachyDose. Calculations are performed for 103Pd, 125I, 131Cs seeds and 50 and 100 keV point sources for 17 implant positions. Doses to treatment volumes, ipsilateral lung, aorta, and heart are determined and compared to those determined using the TG-43 approach. Considerable variation with source energy and differences between model-based and TG-43 doses are found for both treatment volumes and organs. Doses to the heart and aorta generally increase with increasing source energy. TG-43 underestimates the dose to the heart and aorta for all implants except those nearest to these organs where the dose is overestimated. Results suggest that model-based dose calculations are crucial for selecting prescription doses, comparing clinical endpoints, and studying radiobiological effects for permanent implant lung brachytherapy.

  9. Multiscale multimodal fusion of histological and MRI volumes for characterization of lung inflammation

    NASA Astrophysics Data System (ADS)

    Rusu, Mirabela; Wang, Haibo; Golden, Thea; Gow, Andrew; Madabhushi, Anant

    2013-03-01

    Mouse lung models facilitate the investigation of conditions such as chronic inflammation which are associated with common lung diseases. The multi-scale manifestation of lung inflammation prompted us to use multi-scale imaging - both in vivo, ex vivo MRI along with ex vivo histology, for its study in a new quantitative way. Some imaging modalities, such as MRI, are non-invasive and capture macroscopic features of the pathology, while others, e.g. ex vivo histology, depict detailed structures. Registering such multi-modal data to the same spatial coordinates will allow the construction of a comprehensive 3D model to enable the multi-scale study of diseases. Moreover, it may facilitate the identification and definition of quantitative of in vivo imaging signatures for diseases and pathologic processes. We introduce a quantitative, image analytic framework to integrate in vivo MR images of the entire mouse with ex vivo histology of the lung alone, using lung ex vivo MRI as conduit to facilitate their co-registration. In our framework, we first align the MR images by registering the in vivo and ex vivo MRI of the lung using an interactive rigid registration approach. Then we reconstruct the 3D volume of the ex vivo histological specimen by efficient group wise registration of the 2D slices. The resulting 3D histologic volume is subsequently registered to the MRI volumes by interactive rigid registration, directly to the ex vivo MRI, and implicitly to in vivo MRI. Qualitative evaluation of the registration framework was performed by comparing airway tree structures in ex vivo MRI and ex vivo histology where airways are visible and may be annotated. We present a use case for evaluation of our co-registration framework in the context of studying chronic inammation in a diseased mouse.

  10. Stunting and the Prediction of Lung Volumes Among Tibetan Children and Adolescents at High Altitude.

    PubMed

    Weitz, Charles A; Garruto, Ralph M

    2015-12-01

    This study examines the extent to which stunting (height-for-age Z-scores ≤ -2) compromises the use of low altitude prediction equations to gauge the general increase in lung volumes during growth among high altitude populations. The forced vital capacity (FVC) and forced expiratory volume (FEV1) of 208 stunted and 365 non-stunted high-altitude Tibetan children and adolescents between the ages of 6 and 20 years are predicted using the Third National Health and Nutrition Examination Survey (NHANESIII) and the Global Lung Function Initiative (GLF) equations, and compared to observed lung volumes. Stunted Tibetan children show smaller positive deviations from both NHANESIII and GLF prediction equations at most ages than non-stunted children. Deviations from predictions do not correspond to differences in body proportions (sitting heights and chest circumferences relative to stature) between stunted and non-stunted children; but appear compatible with the effects of retarded growth and lung maturation that are likely to exist among stunted children. These results indicate that, before low altitude standards can be used to evaluate the effects of hypoxia, or before high altitude populations can be compared to any other group, it is necessary to assess the relative proportion of stunted children in the samples. If the proportion of stunted children in a high altitude population differs significantly from the proportion in the comparison group, lung function comparisons are unlikely to yield an accurate assessment of the hypoxia effect. The best solution to this problem is to (1) use stature and lung function standards based on the same low altitude population; and (2) assess the hypoxic effect by comparing observed and predicted values among high altitude children whose statures are most like those of children on whom the low altitude spirometric standard is based-preferably high altitude children with HAZ-scores ≥ -1.

  11. Effect of weight loss on operational lung volumes and oxygen cost of breathing in obese women

    PubMed Central

    Bhammar, Dharini M.; Stickford, Jonathon L.; Bernhardt, Vipa; Babb, Tony G.

    2015-01-01

    Background The effect of moderate weight loss on operational lung volumes during exercise and the oxygen (O2) cost of breathing are unknown in obese women but could have important implications regarding exercise endurance. Methods In twenty-nine obese women (33 ± 8yr, 97 ± 14kg, BMI: 36 ± 4, body fat: 45.6 ± 4.5%; means ± SD), body composition, fat distribution (by MRI), pulmonary function, operational lung volumes during exercise, and the O2 cost of breathing during eucapnic voluntary hyperpnea ( V˙O2 vs. V˙E slope) were studied before and after a 12-week diet and resistance exercise weight loss program. Results Participants lost 7.5 ± 3.1kg or ≈8% of body weight (p < 0.001), but fat distribution remained unchanged. After weight loss, lung volume subdivisions at rest were increased (p < 0.05) and were moderately associated (p < 0.05) with changes in weight. End-expiratory lung volume (%Total Lung Capacity) increased at rest and during constant load exercise (p < 0.05). O2 cost of breathing was reduced by 16% (2.52 ± 1.02 to 2.11 ± 0.72ml/L; P=0.003). As a result, O2 uptake of the respiratory muscles (V˙O2Resp), estimated as the product of O2 cost of breathing and exercise V˙E during cycling at 60W, was significantly reduced by 27 ± 31ml (P<0.001), accounting for 46% of the reduction in total body V˙O2 during cycling at 60W. Conclusions Moderate weight loss yields important improvements in respiratory function at rest and during submaximal exercise in otherwise healthy obese women. These changes in breathing load could have positive effects on the exercise endurance and adherence to physical activity. PMID:26869243

  12. Water Permeability Adjusts Resorption in Lung Epithelia to Increased Apical Surface Liquid Volumes.

    PubMed

    Schmidt, Hanna; Michel, Christiane; Braubach, Peter; Fauler, Michael; Neubauer, Daniel; Thompson, Kristin E; Frick, Manfred; Mizaikoff, Boris; Dietl, Paul; Wittekindt, Oliver H

    2016-11-04

    The apical surface liquid layer (ASL) covers the airways and forms a first line of defense against pathogens. Maintenance of ASL volume by airway epithelia is essential for maintaining lung function. The proteolytic activation of epithelial Na(+) channels (ENaC) is believed to be the dominating mechanism to cope with increases in ASL volumes. Alternative mechanisms, in particular increases in epithelial water permeability (Posm), have so far been regarded as rather less important. However, most studies mainly addressed immediate effects upon apical volume expansion (AVE) and increases in ASL. This study addresses the response of lung epithelia to long term AVE. NCI-H441 cells and primary human tracheal epithelial cells (hTEpC), both cultivated at air liquid interface conditions, were used as models for the lung epithelium. AVE was established by adding isotonic solution onto the apical surface of differentiated lung epithelia and time course of ASL volume restoration was assessed by the D2O dilution method. Concomitant ion transport was investigated in Ussing chambers. We identified a low resorptive state (lowRS) immediately after AVE, which coincided with proteolytic ion transport activation within 10 to 15 min after AVE. The main clearance of excess ASL occurred during a delayed (hours after AVE) high resorptive state (highRS), which did not correlate with ion transport activation. Instead, highRS onset coincided with an increase in Posm, which depended on aquapoprin upregulation. In summary, our data demonstrates that, besides to ion transport activation, modulation of Posm is a major mechanism to compensate long-term AVE in lung epithelia.

  13. [Arteriovenous shunting in obesity, its relation to lung volume].

    PubMed

    Martínez Guerra, M L; Fernández Bonetti, P; Sandoval Zárate, J; Lupi Herrera, E

    1981-01-01

    Thirty-five patients with an average overweight of 67.1% were studied. Pulmonary restriction of a variable degree was found in 68.6/; in 60% due to reduction of respiratory reserve volume. Bronchial obstruction was detected in 57% as measured by forced midexpiratory flow (25-75%). In addition, 14% showed a decrease of 75-85% in forced expiratory flow, which suggested that the pathology was located in the small respiratory airways. The PaO2 while breathing room air and in a resting state was of 52.6 +/- 9.42 mmHg, and after breathing it increased to 69.07 +/- 11.01 mmHg. The PaO2 breathing inspiratory fractions of 99.6% O2 in a resting condition was 309.34 +/- 70.07 mmHg, and after deep breathing it rose to 354.0 +/- 64.27 mmHg. The mechanisms which produce hypoxemia in the obese were analysed and it was concluded that they were due fundamentally to alterations of the ventilation perfusion ratio and to an increase of the venous-arterial shunt. In some cases, alveolar hypoventilation contributed (Pickwick syndrome). By increasing the pulmonary volume with deep breathing, the ventilation perfusion ratio improves or becomes normal, likewise, the venous-arterial shunt can improve or persist as the only cause of hypoxemia.

  14. Expiratory computed tomographic techniques: a cause of a poor rate of change in lung volume.

    PubMed

    Morikawa, Keiko; Okada, Fumito; Mori, Hiromu

    2015-01-01

    Ninety-nine patients (29 males and 70 females; mean age, 57.1 years; range, 22-81 years) were included in this study to evaluate the factors affecting smaller lung volume changes in expiratory high-resolution computed tomography performed to depict air trapping. All patients underwent inspiratory and expiratory chest thin-section CT examinations and pulmonary function tests. Air trapping on CT images was graded subjectively. All variables (age, sex, diagnosis, pulmonary function index, and air trapping score) were compared with the degree of change in lung volume between the inspiratory and expiratory CT examinations. The variables affecting a lower degree of volume change were vital capacity, forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1.0), and the FEV1.0/FVC ratio. Bronchiolitis obliterans was the dominant diagnosis in patients with insufficient degrees of breath holding and in patients with negative air trapping scores despite an abnormal air trapping index. An insufficient degree of lung changes between inspiration and expiration on CT examinations represented bronchiolitis obliterans, which resulted in low FEV1.0 and FEV1.0/FVC values. Changes in the time gap from the announcement of exhalation and breath holding to the start of scanning most effectively indicated air trapping in patients with bronchiolar disorders.

  15. WE-G-BRD-07: Investigation of Distal Lung Atelectasis Following Stereotactic Body Radiation Therapy Using Regional Lung Volume Changes Between Pre- and Post- Treatment CT Scans

    SciTech Connect

    Diot, Q; Kavanagh, B; Miften, M

    2014-06-15

    Purpose: To propose a quantitative method using lung deformations to differentiate between radiation-induced fibrosis and potential airway stenosis with distal atelectasis in patients treated with stereotactic body radiation therapy (SBRT) for lung tumors. Methods: Twenty-four lung patients with large radiation-induced density increases outside the high dose region had their pre- and post-treatment CT scans manually registered. They received SBRT treatments at our institution between 2002 and 2009 in 3 or 5 fractions, to a median total dose of 54Gy (range, 30–60). At least 50 anatomical landmarks inside the lung (airway branches) were paired for the pre- and post-treatment scans to guide the deformable registration of the lung structure, which was then interpolated to the whole lung using splines. Local volume changes between the planning and follow-up scans were calculated using the deformation field Jacobian. Hyperdense regions were classified as atelectatic or fibrotic based on correlations between regional density increases and significant volume contractions compared to the surrounding tissues. Results: Out of 24 patients, only 7 demonstrated a volume contraction that was at least one σ larger than the remaining lung average. Because they did not receive high doses, these shrunk hyperdense regions were likely showing distal atelectasis resulting from radiation-induced airway stenosis rather than conventional fibrosis. On average, the hyperdense regions extended 9.2 cm farther than the GTV contours but not significantly more than 8.6 cm for the other patients (p>0.05), indicating that a large offset between the radiation and hyperdense region centers is not a good surrogate for atelectasis. Conclusion: A method based on the relative comparison of volume changes between different dates was developed to identify potential lung regions experiencing distal atelectasis. Such a tool is essential to study which lung structures need to be avoided to prevent

  16. Absolute and relative dose surface and dose volume histograms of the bladder: which one is the most representative for the actual treatment?

    NASA Astrophysics Data System (ADS)

    Hoogeman, Mischa S.; Peeters, Stephanie T. H.; de Bois, Josien; Lebesque, Joos V.

    2005-08-01

    The purpose of this study was to quantify to what extent relative and absolute bladder dose-volume and dose-surface histograms of the planning CT scan were representative for the actual treatment. We used data of 17 patients, who each received 11 repeat CT scans and a planning CT scan. The repeat CT scans were matched on the planning CT scan by the bony anatomy. Clinical treatment plans were used to evaluate the impact of bladder filling changes on the four histogram types. The impact was quantified by calculating for this patient group the correlation coefficient between the planning histogram and the treatment histogram. We found that the absolute dose-surface histogram was the most representative one for the actual treatment.

  17. Quantification of Regional Interstitial Lung Disease from CT-derived Fractional Tissue Volume: A Lung Tissue Research Consortium Study

    PubMed Central

    Yilmaz, Cuneyt; Watharkar, Snehal S.; de Leon, Alberto Diaz; Garcia, Christine K.; Patel, Nova C.; Jordan, Kirk G.; Hsia, Connie C.W.

    2011-01-01

    Rationale and Objectives Evaluation of chest CT is usually qualitative or semi-quantitative, resulting in subjective descriptions often by different observers over time and imprecise determinations of disease severity within distorted lobes. There is a need for standardized imaging biomarkers to quantify regional disease, maximize diagnostic yield, and facilitate multi-center comparisons. We applied lobe-based voxelwise image analysis to derive regional air (Vair) and tissue (Vtissue) volumes and fractional tissue volume (FTV=tissue/[tissue+air] volume) as internally standardized parameter for assessing interstitial lung disease (ILD). Materials and Methods High-resolution CT was obtained at supine and prone end-inspiration and supine end-expiration in 29 patients with ILD and 20 normal subjects. Lobar Vair, Vtissue, and FTV were expressed along standard coordinate axes. Results In normal subjects from end-inspiration to end-expiration, total Vair declined 43%, FTV increased ~80% while Vtissue remained unchanged. With increasing ILD, Vair declined and Vtissue rose in all lobes; FTV increased with a peripheral-to-central progression inversely correlated to spirometry and lung diffusing capacity (R2=0.57–0.75, prone end-inspiration). Inter- and intra-lobar coefficients of variation (CVs) of FTV increased 84–148% in mild-to-moderate ILD, indicating greater spatial heterogeneity, then normalized in severe ILD. Analysis of discontinuous images incurs <3% error compared to consecutive images. Conclusions These regional attenuation-based biomarkers could quantify heterogeneous parenchymal disease in distorted lobes, detect mild ILD involvement in all lobes and describe the pattern of disease progression. The next step would be to study a larger series, examine reproducibility and follow longitudinal changes in correlation with clinical and functional indices. PMID:21596593

  18. Dose as a Function of Lung Volume and Planned Treatment Volume in Helical Tomotherapy Intensity-Modulated Radiation Therapy-Based Stereotactic Body Radiation Therapy for Small Lung Tumors

    SciTech Connect

    Baisden, Joseph M.; Romney, Davis A.; Reish, Andrew G.; Cai Jing; Sheng Ke; Jones, David R.; Benedict, Stanley H.; Read, Paul W.; Larner, James M. . E-mail: JML2P@virginia.edu

    2007-07-15

    Purpose: To evaluate the limitations of Hi-Art Helical Tomotherapy (Middleton, WI) stereotactic body radiotherapy (SBRT) for lung lesions, and to provide an initial report on patients treated with this method. Stereotactic body radiotherapy was shown to be an effective, well-tolerated treatment for early-stage, non-small-cell lung carcinoma (NSCLC). The Radiation Therapy Oncology Group (RTOG) 0236 protocol is currently evaluating three-dimensional conformal SBRT that delivers 60 Gy in three fractions. Methods and Materials: Inverse treatment planning for hypothetical lung gross tumor volumes (GTV) and planned treatment volume (PTV) expansions were performed. We tested the hypothesis that the maximum acceptable dose (MAD) to be delivered to the lesion by SBRT could be predicted by PTV and lung volume. Dose constraints on normal tissue were as designated by the RTOG protocol. Inverse planning was performed to find the maximum tolerated SBRT dose up to 60 Gy. Results: Regression analysis of the data obtained indicated a linear relationship between MAD, PTV, and lung volume. This generated two equations which may be useful predictive tools. Seven patients with Stage I and II NSCLC treated at University of Virginia with this method tolerated the treatment extremely well, and suffered no greater than grade I toxicity, with no evidence of disease recurrence in follow-up from 2-20 months. Conclusions: Helical tomotherapy SBRT for lung lesions is well-tolerated. In addition, the likely MAD for patients considered for this type of treatment can be predicted by PTV and lung volume.

  19. Lung function, transfusion, pulmonary capillary blood volume and sickle cell disease.

    PubMed

    Lunt, Alan; McGhee, Emily; Robinson, Polly; Rees, David; Height, Susan; Greenough, Anne

    2016-02-01

    Lung function abnormalities occur in children with sickle cell disease (SCD) and may be associated with elevated pulmonary blood volume. To investigate that association, we determined whether blood transfusion in SCD children acutely increased pulmonary capillary blood volume (PCBV) and increased respiratory system resistance (Rrs5). Measurements of Rrs5 and spirometry were made before and after blood transfusion in 18 children, median age 14.2 (6.6-18.5) years. Diffusing capacity for carbon monoxide and nitric oxide were assessed to calculate the PCBV. Post transfusion, the median Rrs5 had increased from 127.4 to 141.3% predicted (p<0.0001) and pulmonary capillary blood volume from 39.7 to 64.1 ml/m2 (p<0.0001); forced expiratory volume in one second (p=0.0056) and vital capacity (p=0.0008) decreased. The increase in Rrs5 correlated with the increase in PCBV (r=0.50, p=0.0493). Increased pulmonary capillary blood volume may at least partially explain the lung function abnormalities in SCD children.

  20. Action of the isolated canine diaphragm on the lower ribs at high lung volumes.

    PubMed

    De Troyer, André; Wilson, Theodore A

    2014-10-15

    The normal diaphragm has an inspiratory action on the lower ribs, but subjects with chronic obstructive pulmonary disease commonly have an inward displacement of the lateral portions of the lower rib cage during inspiration. This paradoxical displacement, conventionally called 'Hoover's sign', has traditionally been attributed to the direct action of radially oriented diaphragmatic muscle fibres. In the present study, the inspiratory intercostal muscles in all interspaces in anaesthetized dogs were severed so that the diaphragm was the only muscle active during inspiration. The displacements of the lower ribs along the craniocaudal and laterolateral axes and the changes in pleural pressure (∆Ppl) and transdiaphragmatic pressure were measured during occluded breaths and mechanical ventilation at different lung volumes between functional residual capacity (FRC) and total lung capacity. From these data, the separate effects on rib displacement of ∆Ppl and of the force exerted by the diaphragm on the ribs were determined. Isolated spontaneous diaphragm contraction at FRC displaced the lower ribs cranially and outward, but this motion was progressively reversed into a caudal and inward motion as lung volume increased. However, although the force exerted by the diaphragm on the ribs decreased with increasing volume, it continued to displace the ribs cranially and outward. These observations suggest that Hoover's sign is usually caused by the decrease in the zone of apposition and, thus, by the dominant effect of ∆Ppl on the lower ribs, rather than an inward pull from the diaphragm.

  1. Effects of tongue position and lung volume on voluntary maximal tongue protrusion force in humans.

    PubMed

    Saboisky, Julian P; Luu, Billy L; Butler, Jane E; Gandevia, Simon C

    2015-01-15

    Maximal voluntary protrusion force of the human tongue has not been examined in positions beyond the incisors or at different lung volumes. Tongue force was recorded with the tongue tip at eight positions relative to the incisors (12 and 4mm protrusion, neutral and 4, 12, 16, 24 and 32mm retraction) at functional residual capacity (FRC), total lung capacity (TLC) and residual volume (RV) in 15 healthy subjects. Maximal force occurred between 12mm and 32mm retraction (median 16mm). Maximum force at FRC was reproducible at the optimal tongue position across sessions (P=0.68). Across all positions at FRC the average force was highest at 24mm retraction (28.3±5.3N, mean±95% CI) and lowest at 12mm protrusion (49.1±4.6% maximum; P<0.05). Across all tongue positions, maximal force was on average 9.3% lower at FRC than TLC and RV (range: 4.5-12.7% maximum, P<0.05). Retracted positions produce higher-force protrusions with a small effect of lung volume.

  2. Relationship Between LIBS Ablation and Pit Volume for Geologic Samples: Applications for the In Situ Absolute Geochronology

    NASA Technical Reports Server (NTRS)

    Devismes, Damien; Cohen, Barbara; Miller, J.-S.; Gillot, P.-Y.; Lefevre, J.-C.; Boukari, C.

    2014-01-01

    These first results demonstrate that LIBS spectra can be an interesting tool to estimate the ablated volume. When the ablated volume is bigger than 9.10(exp 6) cubic micrometers, this method has less than 10% of uncertainties. Far enough to be directly implemented in the KArLE experiment protocol. Nevertheless, depending on the samples and their mean grain size, the difficulty to have homogeneous spectra will increase with the ablated volume. Several K-Ar dating studies based on this approach will be implemented. After that, the results will be shown and discussed.

  3. Correlated Variability in the Breathing Pattern and End-Expiratory Lung Volumes in Conscious Humans

    PubMed Central

    Dellaca, Raffaele L.; Aliverti, Andrea; Lo Mauro, Antonella; Lutchen, Kenneth R.; Pedotti, Antonio; Suki, Bela

    2015-01-01

    In order to characterize the variability and correlation properties of spontaneous breathing in humans, the breathing pattern of 16 seated healthy subjects was studied during 40 min of quiet breathing using opto-electronic plethysmography, a contactless technology that measures total and compartmental chest wall volumes without interfering with the subjects breathing. From these signals, tidal volume (VT), respiratory time (TTOT) and the other breathing pattern parameters were computed breath-by-breath together with the end-expiratory total and compartmental (pulmonary rib cage and abdomen) chest wall volume changes. The correlation properties of these variables were quantified by detrended fluctuation analysis, computing the scaling exponentα. VT, TTOT and the other breathing pattern variables showed α values between 0.60 (for minute ventilation) to 0.71 (for respiratory rate), all significantly lower than the ones obtained for end-expiratory volumes, that ranged between 1.05 (for rib cage) and 1.13 (for abdomen) with no significant differences between compartments. The much stronger long-range correlations of the end expiratory volumes were interpreted by a neuromechanical network model consisting of five neuron groups in the brain respiratory center coupled with the mechanical properties of the respiratory system modeled as a simple Kelvin body. The model-based α for VT is 0.57, similar to the experimental data. While the α for TTOT was slightly lower than the experimental values, the model correctly predicted α for end-expiratory lung volumes (1.045). In conclusion, we propose that the correlations in the timing and amplitude of the physiological variables originate from the brain with the exception of end-expiratory lung volume, which shows the strongest correlations largely due to the contribution of the viscoelastic properties of the tissues. This cycle-by-cycle variability may have a significant impact on the functioning of adherent cells in the

  4. Correlated variability in the breathing pattern and end-expiratory lung volumes in conscious humans.

    PubMed

    Dellaca, Raffaele L; Aliverti, Andrea; Lo Mauro, Antonella; Lutchen, Kenneth R; Pedotti, Antonio; Suki, Bela

    2015-01-01

    In order to characterize the variability and correlation properties of spontaneous breathing in humans, the breathing pattern of 16 seated healthy subjects was studied during 40 min of quiet breathing using opto-electronic plethysmography, a contactless technology that measures total and compartmental chest wall volumes without interfering with the subjects breathing. From these signals, tidal volume (VT), respiratory time (TTOT) and the other breathing pattern parameters were computed breath-by-breath together with the end-expiratory total and compartmental (pulmonary rib cage and abdomen) chest wall volume changes. The correlation properties of these variables were quantified by detrended fluctuation analysis, computing the scaling exponenta. VT, TTOT and the other breathing pattern variables showed α values between 0.60 (for minute ventilation) to 0.71 (for respiratory rate), all significantly lower than the ones obtained for end-expiratory volumes, that ranged between 1.05 (for rib cage) and 1.13 (for abdomen) with no significant differences between compartments. The much stronger long-range correlations of the end expiratory volumes were interpreted by a neuromechanical network model consisting of five neuron groups in the brain respiratory center coupled with the mechanical properties of the respiratory system modeled as a simple Kelvin body. The model-based α for VT is 0.57, similar to the experimental data. While the α for TTOT was slightly lower than the experimental values, the model correctly predicted α for end-expiratory lung volumes (1.045). In conclusion, we propose that the correlations in the timing and amplitude of the physiological variables originate from the brain with the exception of end-expiratory lung volume, which shows the strongest correlations largely due to the contribution of the viscoelastic properties of the tissues. This cycle-by-cycle variability may have a significant impact on the functioning of adherent cells in the

  5. The Impact of Heart Irradiation on Dose-Volume Effects in the Rat Lung

    SciTech Connect

    Luijk, Peter van Faber, Hette; Meertens, Harm; Schippers, Jacobus M.; Langendijk, Johannes A.; Brandenburg, Sytze; Kampinga, Harm H.; Coppes, Robert P. Ph.D.

    2007-10-01

    Purpose: To test the hypothesis that heart irradiation increases the risk of a symptomatic radiation-induced loss of lung function (SRILF) and that this can be well-described as a modulation of the functional reserve of the lung. Methods and Materials: Rats were irradiated with 150-MeV protons. Dose-response curves were obtained for a significant increase in breathing frequency after irradiation of 100%, 75%, 50%, or 25% of the total lung volume, either including or excluding the heart from the irradiation field. A significant increase in the mean respiratory rate after 6-12 weeks compared with 0-4 weeks was defined as SRILF, based on biweekly measurements of the respiratory rate. The critical volume (CV) model was used to describe the risk of SRILF. Fits were done using a maximum likelihood method. Consistency between model and data was tested using a previously developed goodness-of-fit test. Results: The CV model could be fitted consistently to the data for lung irradiation only. However, this fitted model failed to predict the data that also included heart irradiation. Even refitting the model to all data resulted in a significant difference between model and data. These results imply that, although the CV model describes the risk of SRILF when the heart is spared, the model needs to be modified to account for the impact of dose to the heart on the risk of SRILF. Finally, a modified CV model is described that is consistent to all data. Conclusions: The detrimental effect of dose to the heart on the incidence of SRILF can be described by a dose dependent decrease in functional reserve of the lung.

  6. Tumor Volume Is a Prognostic Factor in Non-Small-Cell Lung Cancer Treated With Chemoradiotherapy

    SciTech Connect

    Alexander, Brian M.; Othus, Megan; Caglar, Hale B.

    2011-04-01

    Purpose: To investigate whether primary tumor and nodal volumes defined on radiotherapy planning scans are correlated with outcome (survival and recurrence) after combined-modality treatment. Methods and Materials: A retrospective review of patients with Stage III non-small-cell lung cancer treated with chemoradiation at Brigham and Women's Hospital/Dana-Farber Cancer Institute from 2000 to 2006 was performed. Tumor and nodal volume measurements, as computed by Eclipse (Varian, Palo Alto, CA), were used as independent variables, along with existing clinical factors, in univariate and multivariate analyses for association with outcomes. Results: For patients treated with definitive chemoradiotherapy, both nodal volume (hazard ratio [HR], 1.09; p < 0.01) and tumor volume (HR, 1.03; p < 0.01) were associated with overall survival on multivariate analysis. Both nodal volume (HR, 1.10; p < 0.01) and tumor volume (HR, 1.04; p < 0.01) were also associated with local control but not distant metastases. Conclusions: In addition to traditional surgical staging variables, disease burden, measured by primary tumor and nodal metastases volume, provides information that may be helpful in determining prognosis and identifying groups of patients for which more aggressive local therapy is warranted.

  7. Clinical implications of defining the gross tumor volume with combination of CT and {sup 18}FDG-positron emission tomography in non-small-cell lung cancer

    SciTech Connect

    Grills, Inga S. . E-mail: igrills@beaumont.edu; Yan Di; Black, Quinten C.; Wong, Ching-Yee O.; Martinez, Alvaro A.; Kestin, Larry L.

    2007-03-01

    Purpose: To compare the planning target volume (PTV) definitions for computed tomography (CT) vs. positron emission tomography (PET) in non-small-cell lung cancer (NSCLC). Methods and Materials: A total of 21 patients with NSCLC underwent three-dimensional conformal radiotherapy planning. All underwent a staging F-18 fluorodeoxyglucose-position emission tomography ({sup 18}FDG-PET) scan and underwent treatment simulation using CT plus a separate planning {sup 18}FDG-PET scan. Three sets of target volumes were defined: Set 1, CT volumes (CT tumor + staging PET nodal disease); Set 2, PET volumes (planning PET tumor {l_brace}gross tumor volume (GTV) = [(0.3069 x mean standardized uptake value) + 0.5853]){r_brace}; Set 3, composite CT-PET volumes (fused CT-PET tumor). Sets 1 and 2 were compared using a matching index. Three-dimensional conformal radiotherapy plans were created using the Set 1 (CT) volumes; and coverage of the Set 3 (composite) volumes was evaluated. Separate three-dimensional conformal radiotherapy plans were designed for the Set 3 volumes. Results: For the primary tumor GTV, the Set 1 (CT) volume was larger than the Set 2 (PET) volume in 48%, smaller in 33%, and equal in 19%. The mean matching index was 0.65 (35% CT-PET mismatch). Although quantitatively similar, the volumes differed qualitatively. The Set 3 (composite) volume was larger than either CT or PET alone in 62%, smaller in 24%, and equal in 14%. The dose-volume histogram parameters did not differ among the plans for Set 1 (CT) vs. Set 3 (composite) volumes. Small portions of the Set 3 PTV were significantly underdosed in 40% of cases using the CT-only plan. Conclusion: Computed tomography and PET are complementary and should be obtained in the treatment position and fused to define the GTV for NSCLC. Although the quantitative absolute target volume is sometimes similar, the qualitative target locations can be substantially different, leading to underdosage of the target when planning is

  8. Dose-Volume Parameters Predict for the Development of Chest Wall Pain After Stereotactic Body Radiation for Lung Cancer

    SciTech Connect

    Mutter, Robert W.; Liu Fan; Abreu, Andres; Yorke, Ellen; Jackson, Andrew; Rosenzweig, Kenneth E.

    2012-04-01

    Purpose: Chest wall (CW) pain has recently been recognized as an important adverse effect of stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC). We developed a dose-volume model to predict the development of this toxicity. Methods and Materials: A total of 126 patients with primary, clinically node-negative NSCLC received three to five fractions of SBRT to doses of 40-60 Gy and were prospectively followed. The dose-absolute volume histograms of two different definitions of the CW as an organ at risk (CW3cm and CW2cm) were examined for all 126 patients. Results: With a median follow-up of 16 months, the 2-year estimated actuarial incidence of Grade {>=} 2 CW pain was 39%. The median time to onset of Grade {>=} 2 CW pain (National Cancer Institute Common Terminology Criteria for Adverse Events, Version 3.0) was 9 months. There was no predictive advantage for biologically corrected dose over physical dose. Neither fraction number (p = 0.07) nor prescription dose (p = 0.07) were significantly correlated with the development of Grade {>=} 2 CW pain. Cox Proportional Hazards analysis identified significant correlation with a broad range of dose-volume combinations, with the CW volume receiving 30 Gy (V30) as one of the strongest predictors (p < 0.001). CW2cm consistently enabled better prediction of CW toxicity. When a physical dose of 30 Gy was received by more than 70 cm{sup 3} of CW2cm, there was a significant correlation with Grade {>=} 2 CW pain (p = 0.004). Conclusions: CW toxicity after SBRT is common and long-term follow-up is needed to identify affected patients. A volume of CW {>=} 70 cm{sup 3} receiving 30 Gy is significantly correlated with Grade {>=} 2 CW pain. We are currently applying this constraint at our institution for patients receiving thoracic SBRT. An actuarial atlas of our data is provided as an electronic supplement to facilitate data-sharing and meta-analysis relating to CW pain.

  9. The pressure-volume curve is greatly modified by recruitment. A mathematical model of ARDS lungs.

    PubMed

    Hickling, K G

    1998-07-01

    A mathematical model of the ARDS lung, with simulated gravitational superimposed pressure, evaluated the effect of varying alveolar threshold opening pressures (TOP), PEEP and peak inspiratory pressure (PIP) on the static pressure-volume (PV) curve. The lower inflection point (Pflex) was affected by SP and TOP, and did not accurately indicate PEEP required to prevent end-expiratory collapse. Reinflation of collapsed lung units (recruitment) continued on the linear portion of the PV curve, which had a slope at any volume greater than the total compliance of aerated alveoli. As recruitment diminished, the reduced PV slope could produce an upper Pflex at 20 to 30 cm H2O pressure. An upper Pflex caused by alveolar overdistension could be modified or eliminated by recruitment with high TOP. With constant PIP as PEEP increased, and TOP range of 5 to 60 cm H2O, PEEP to prevent end-expiratory collapse was indicated by minimum PV slope above 20 cm H2O, minimum hysteresis, and maximum volume at a pressure of 20 cm H2O. With constant inflation volume as PEEP increased, the effect on PV slope was unpredictable. Although increased PV slope indicated recruitment, maximum PV slope usually underestimated PEEP required to prevent end-expiratory collapse. Therefore, with this model the PV curve did not reliably predict optimal ventilator settings.

  10. Cone-Beam CT Localization of Internal Target Volumes for Stereotactic Body Radiotherapy of Lung Lesions

    SciTech Connect

    Wang Zhiheng Wu, Q. Jackie; Marks, Lawrence B.; Larrier, Nicole; Yin Fangfang

    2007-12-01

    Purpose: In this study, we investigate a technique of matching internal target volumes (ITVs) in four-dimensional (4D) simulation computed tomography (CT) to the composite target volume in free-breathing on-board cone-beam (CB) CT. The technique is illustrated by using both phantom and patient cases. Methods and Materials: A dynamic phantom with a target ball simulating respiratory motion with various amplitude and cycle times was used to verify localization accuracy. The dynamic phantom was scanned using simulation CT with a phase-based retrospective sorting technique. The ITV was then determined based on 10 sets of sorted images. The size and epicenter of the ITV identified from 4D simulation CT images and the composite target volume identified from on-board CBCT images were compared to assess localization accuracy. Similarly, for two clinical cases of patients with lung cancer, ITVs defined from 4D simulation CT images and CBCT images were compared. Results: For the phantom, localization accuracy between the ITV in 4D simulation CT and the composite target volume in CBCT was within 1 mm, and ITV was within 8.7%. For patient cases, ITVs on simulation CT and CBCT were within 8.0%. Conclusion: This study shows that CBCT is a useful tool to localize ITV for targets affected by respiratory motion. Verification of the ITV from 4D simulation CT using on-board free-breathing CBCT is feasible for the target localization of lung tumors.

  11. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    PubMed

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint.

  12. GGO nodule volume-preserving nonrigid lung registration using GLCM texture analysis.

    PubMed

    Park, Seongjin; Kim, Bohyoung; Lee, Jeongjin; Goo, Jin Mo; Shin, Yeong-Gil

    2011-10-01

    In lung cancer screening, benign and malignant nodules can be classified through nodule growth assessment by the registration and, then, subtraction between follow-up computed tomography scans. During the registration, the volume of nodule regions in the floating image should be preserved, whereas the volume of other regions in the floating image should be aligned to that in the reference image. However, ground glass opacity (GGO) nodules are very elusive to automatically segment due to their inhomogeneous interior. In other words, it is difficult to automatically define the volume-preserving regions of GGO nodules. In this paper, we propose an accurate and fast nonrigid registration method. It applies the volume-preserving constraint to candidate regions of GGO nodules, which are automatically detected by gray-level cooccurrence matrix (GLCM) texture analysis. Considering that GGO nodules can be characterized by their inner inhomogeneity and high intensity, we identify the candidate regions of GGO nodules based on the homogeneity values calculated by the GLCM and the intensity values. Furthermore, we accelerate our nonrigid registration by using Compute Unified Device Architecture (CUDA). In the nonrigid registration process, the computationally expensive procedures of the floating-image transformation and the cost-function calculation are accelerated by using CUDA. The experimental results demonstrated that our method almost perfectly preserves the volume of GGO nodules in the floating image as well as effectively aligns the lung between the reference and floating images. Regarding the computational performance, our CUDA-based method delivers about 20× faster registration than the conventional method. Our method can be successfully applied to a GGO nodule follow-up study and can be extended to the volume-preserving registration and subtraction of specific diseases in other organs (e.g., liver cancer).

  13. Influence of heart failure on resting lung volumes in patients with COPD

    PubMed Central

    de Souza, Aline Soares; Sperandio, Priscila Abreu; Mazzuco, Adriana; Alencar, Maria Clara; Arbex, Flávio Ferlin; de Oliveira, Mayron Faria; O'Donnell, Denis Eunan; Neder, José Alberto

    2016-01-01

    ABSTRACT Objective: To evaluate the influence of chronic heart failure (CHF) on resting lung volumes in patients with COPD, i.e., inspiratory fraction-inspiratory capacity (IC)/TLC-and relative inspiratory reserve-[1 − (end-inspiratory lung volume/TLC)]. Methods: This was a prospective study involving 56 patients with COPD-24 (23 males/1 female) with COPD+CHF and 32 (28 males/4 females) with COPD only-who, after careful clinical stabilization, underwent spirometry (with forced and slow maneuvers) and whole-body plethysmography. Results: Although FEV1, as well as the FEV1/FVC and FEV1/slow vital capacity ratios, were higher in the COPD+CHF group than in the COPD group, all major "static" volumes-RV, functional residual capacity (FRC), and TLC-were lower in the former group (p < 0.05). There was a greater reduction in FRC than in RV, resulting in the expiratory reserve volume being lower in the COPD+CHF group than in the COPD group. There were relatively proportional reductions in FRC and TLC in the two groups; therefore, IC was also comparable. Consequently, the inspiratory fraction was higher in the COPD+CHF group than in the COPD group (0.42 ± 0.10 vs. 0.36 ± 0.10; p < 0.05). Although the tidal volume/IC ratio was higher in the COPD+CHF group, the relative inspiratory reserve was remarkably similar between the two groups (0.35 ± 0.09 vs. 0.44 ± 0.14; p < 0.05). Conclusions: Despite the restrictive effects of CHF, patients with COPD+CHF have relatively higher inspiratory limits (a greater inspiratory fraction). However, those patients use only a part of those limits, probably in order to avoid critical reductions in inspiratory reserve and increases in elastic recoil. PMID:27832235

  14. Lung Nodule Volume Quantification and Shape Differentiation with an Ultra-High Resolution Technique on a Photon Counting Detector CT System

    PubMed Central

    Zhou, W.; Montoya, J.; Gutjahr, R.; Ferrero, A.; Halaweish, A.; Kappler, S.; McCollough, C.; Leng, S.

    2017-01-01

    A new ultra high-resolution (UHR) mode has been implemented on a whole body photon counting-detector (PCD) CT system. The UHR mode has a pixel size of 0.25 mm by 0.25 mm at the iso-center, while the conventional (macro) mode is limited to 0.5 mm by 0.5 mm. A set of synthetic lung nodules (two shapes, five sizes, and two radio-densities) was scanned using both the UHR and macro modes and reconstructed with 2 reconstruction kernels (4 sets of images in total). Linear regression analysis was performed to compare measured nodule volumes from CT images to reference volumes. Surface curvature was calculated for each nodule and the full width half maximum (FWHM) of the curvature histogram was used as a shape index to differentiate sphere and star shape nodules. Receiver operating characteristic (ROC) analysis was performed and area under the ROC curve (AUC) was used as a figure of merit for the differentiation task. Results showed strong linear relationship between measured nodule volume and reference standard for both UHR and macro mode. For all nodules, volume estimation was more accurate using UHR mode with sharp kernel (S80f), with lower mean absolute percent error (MAPE) (6.5%) compared with macro mode (11.1% to 12.9%). The improvement of volume measurement from UHR mode was more evident particularly for small nodule size (3mm, 5mm), or star-shape nodules. Images from UHR mode with sharp kernel (S80f) consistently demonstrated the best performance (AUC = 0.85) when separating star from sphere shape nodules among all acquisition and reconstruction modes. Our results showed the advantages of UHR mode on a PCD CT scanner in lung nodule characterization. Various clinical applications, including quantitative imaging, can benefit substantially from this high resolution mode. PMID:28392613

  15. Lung protection: an intervention for tidal volume reduction in a teaching intensive care unit

    PubMed Central

    Briva, Arturo; Gaiero, Cristina

    2016-01-01

    Objective To determine the effect of feedback and education regarding the use of predicted body weight to adjust tidal volume in a lung-protective mechanical ventilation strategy. Methods The study was performed from October 2014 to November 2015 (12 months) in a single university polyvalent intensive care unit. We developed a combined intervention (education and feedback), placing particular attention on the importance of adjusting tidal volumes to predicted body weight bedside. In parallel, predicted body weight was estimated from knee height and included in clinical charts. Results One hundred fifty-nine patients were included. Predicted body weight assessed by knee height instead of visual evaluation revealed that the delivered tidal volume was significantly higher than predicted. After the inclusion of predicted body weight, we observed a sustained reduction in delivered tidal volume from a mean (standard error) of 8.97 ± 0.32 to 7.49 ± 0.19mL/kg (p < 0.002). Furthermore, the protocol adherence was subsequently sustained for 12 months (delivered tidal volume 7.49 ± 0.54 versus 7.62 ± 0.20mL/kg; p = 0.103). Conclusion The lack of a reliable method to estimate the predicted body weight is a significant impairment for the application of a worldwide standard of care during mechanical ventilation. A combined intervention based on education and repeated feedbacks promoted sustained tidal volume education during the study period (12 months). PMID:27925055

  16. Assessment of volume and leak measurements during CPAP using a neonatal lung model.

    PubMed

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.

  17. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    PubMed

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  18. A Pilot Study on the Feasibility of Interventional Lung Volume Reduction

    SciTech Connect

    Wang Wansheng; Dong Yonghua Liu Bin; Zhu Chi; Yu Yongqiang

    2008-01-15

    The objective of this study was to evaluate the feasibility and safety of lung volume reduction by transbronchial alcohol and lipiodol suspension infusion with the aid of balloon-tipped catheter occlusion. Twenty-six healthy adult rabbits were divided into four treatment groups: alcohol and lipiodol suspension infusion (n = 8), lipiodol infusion (n = 8), alcohol infusion (n = 5), or bronchial lumen occlusion (n = 5). After selective lobar or segmental bronchial catheterization using a balloon-tipped occlusion catheter, the corresponding drug infusion was performed. Bone cement was used to occlude the bronchial lumen in the occlusion group. The animals were followed up for 10 weeks by chest X-ray and computed tomography (CT), and then the whole lungs were harvested for histological examination. Alcohol and lipiodol suspension or lipiodol could be stably retained in alveoli in the first two groups based on chest X-ray and CT, but obvious collapse only occurred in the group receiving alcohol and lipiodol suspension or the bronchial lumen occlusion group. Histological examination revealed damage and disruption of the alveolar epithelium and fibrosis in related lung tissue in the group receiving alcohol and lipiodol suspension. Similar changes were seen in the bronchial lumen occlusion group, apart from obvious marginal emphysema of the target areas in two animals. Interstitial pneumonia and dilated alveoli existed in some tissue in target areas in the lipiodol group, in which pulmonary fibrosis obliterating alveoli also occurred. Chronic alveolitis and pleural adhesion in target areas occurred in the group infused with alcohol alone, whereas visceral pleura of the other three groups was regular and no pleural effusion or adhesion was found. Alcohol and lipiodol suspension that is stably retained in alveoli can result in significant lung volume reduction. Through alcohol and lipiodol suspension infusion, obstructive emphysema or pneumonia arising from bronchial lumen

  19. Physiological and Computed Tomographic Predictors of Outcome from Lung Volume Reduction Surgery

    PubMed Central

    Washko, George R.; Martinez, Fernando J.; Hoffman, Eric A.; Loring, Stephen H.; Estépar, Raúl San José; Diaz, Alejandro A.; Sciurba, Frank C.; Silverman, Edwin K.; Han, MeiLan K.; DeCamp, Malcolm; Reilly, John J.

    2010-01-01

    Rationale: Previous investigations have identified several potential predictors of outcomes from lung volume reduction surgery (LVRS). A concern regarding these studies has been their small sample size, which may limit generalizability. We therefore sought to examine radiographic and physiologic predictors of surgical outcomes in a large, multicenter clinical investigation, the National Emphysema Treatment Trial. Objectives: To identify objective radiographic and physiological indices of lung disease that have prognostic value in subjects with chronic obstructive pulmonary disease being evaluated for LVRS. Methods: A subset of the subjects undergoing LVRS in the National Emphysema Treatment Trial underwent preoperative high-resolution computed tomographic (CT) scanning of the chest and measures of static lung recoil at total lung capacity (SRtlc) and inspiratory resistance (Ri). The relationship between CT measures of emphysema, the ratio of upper to lower zone emphysema, CT measures of airway disease, SRtlc, Ri, the ratio of residual volume to total lung capacity (RV/TLC), and both 6-month postoperative changes in FEV1 and maximal exercise capacity were assessed. Measurements and Main Results: Physiological measures of lung elastic recoil and inspiratory resistance were not correlated with improvement in either the FEV1 (R = −0.03, P = 0.78 and R = –0.17, P = 0.16, respectively) or maximal exercise capacity (R = –0.02, P = 0.83 and R = 0.08, P = 0.53, respectively). The RV/TLC ratio and CT measures of emphysema and its upper to lower zone ratio were only weakly predictive of postoperative changes in both the FEV1 (R = 0.11, P = 0.01; R = 0.2, P < 0.0001; and R = 0.23, P < 0.0001, respectively) and maximal exercise capacity (R = 0.17, P = 0.0001; R = 0.15, P = 0.002; and R = 0.15, P = 0.002, respectively). CT assessments of airway disease were not predictive of change in FEV1 or exercise capacity in this cohort. Conclusions: The RV/TLC ratio and CT measures

  20. Effect of CPAP on intrinsic PEEP, inspiratory effort, and lung volume in severe stable COPD

    PubMed Central

    O'Donoghue, F; Catcheside, P; Jordan, A; Bersten, A; McEvoy, R

    2002-01-01

    Background: Intrinsic positive end expiratory pressure (PEEPi) constitutes an inspiratory threshold load on the respiratory muscles, increasing work of breathing. The role of continuous positive airway pressure (CPAP) in alleviating PEEPi in patients with severe stable chronic obstructive pulmonary disease is uncertain. This study examined the effect of CPAP on the inspiratory threshold load, muscle effort, and lung volume in this patient group. Methods: Nine patients were studied at baseline and with CPAP increasing in increments of 1 cm H2O to a maximum of 10 cm H2O. Breathing pattern and minute ventilation (I), dynamic PEEPi, expiratory muscle activity, diaphragmatic (PTPdi/min) and oesophageal (PTPoes/min) pressure-time product per minute, integrated diaphragmatic (EMGdi) and intercostal EMG (EMGic) and end expiratory lung volume (EELV) were measured. Results: Expiratory muscle activity was present at baseline in one subject. In the remaining eight, PEEPi was reduced from a mean (SE) of 2.9 (0.6) cm H2O to 0.9 (0.1) cm H2O (p<0.05). In two subjects expiratory muscle activity contributed to PEEPi at higher pressures. There were no changes in respiratory pattern but I increased from 9.2 (0.6) l/min to 10.7 (1.1) l/min (p<0.05). EMGdi remained stable while EMGic increased significantly. PTPoes/min decreased, although this did not reach statistical significance. PTPdi/min decreased significantly from 242.1 (32.1) cm H2O.s/min to 112.9 (21.7) cm H2O.s/min). EELV increased by 1.1 (0.3) l (p<0.01). Conclusion: High levels of CPAP reduce PEEPi and indices of muscle effort in patients with severe stable COPD, but only at the expense of substantial increases in lung volume. PMID:12037230

  1. High spatiotemporal resolution measurement of regional lung air volumes from 2D phase contrast x-ray images

    SciTech Connect

    Leong, Andrew F. T.; Islam, M. Sirajul; Kitchen, Marcus J.; Fouras, Andreas; Wallace, Megan J.; Hooper, Stuart B.

    2013-04-15

    Purpose: Described herein is a new technique for measuring regional lung air volumes from two-dimensional propagation-based phase contrast x-ray (PBI) images at very high spatial and temporal resolution. Phase contrast dramatically increases lung visibility and the outlined volumetric reconstruction technique quantifies dynamic changes in respiratory function. These methods can be used for assessing pulmonary disease and injury and for optimizing mechanical ventilation techniques for preterm infants using animal models. Methods: The volumetric reconstruction combines the algorithms of temporal subtraction and single image phase retrieval (SIPR) to isolate the image of the lungs from the thoracic cage in order to measure regional lung air volumes. The SIPR algorithm was used to recover the change in projected thickness of the lungs on a pixel-by-pixel basis (pixel dimensions {approx}16.2 {mu}m). The technique has been validated using numerical simulation and compared results of measuring regional lung air volumes with and without the use of temporal subtraction for removing the thoracic cage. To test this approach, a series of PBI images of newborn rabbit pups mechanically ventilated at different frequencies was employed. Results: Regional lung air volumes measured from PBI images of newborn rabbit pups showed on average an improvement of at least 20% in 16% of pixels within the lungs in comparison to that measured without the use of temporal subtraction. The majority of pixels that showed an improvement was found to be in regions occupied by bone. Applying the volumetric technique to sequences of PBI images of newborn rabbit pups, it is shown that lung aeration at birth can be highly heterogeneous. Conclusions: This paper presents an image segmentation technique based on temporal subtraction that has successfully been used to isolate the lungs from PBI chest images, allowing the change in lung air volume to be measured over regions as small as the pixel size. Using

  2. Treatment of emphysema using bronchoscopic lung volume reduction coil technology: an update on efficacy and safety.

    PubMed

    Hartman, Jorine E; Klooster, Karin; Ten Hacken, Nick H T; Slebos, Dirk-Jan

    2015-10-01

    In the last decade several promising bronchoscopic lung volume reduction (BLVR) treatments were developed and investigated. One of these treatments is BLVR treatment with coils. The advantage of this specific treatment is that it works independently of collateral flow, and also shows promise for patients with a more homogeneous emphysema disease distribution. Seven years ago, the very first patients were treated with BLVR coil treatment and currently large randomized, controlled trials are underway. The aim of this article is to review the available literature and provide an update on the current knowledge on the efficacy and safety of BLVR treatment with coils.

  3. Synchronous absolute EIT in three thoracic planes at different gravity levels

    NASA Astrophysics Data System (ADS)

    Hahn, G.; Just, A.; Dittmar, J.; Fromm, K. H.; Quintel, M.

    2013-04-01

    The validity of absolute Electrical Impedance Tomography (a-EIT) for assessment of local lung volume has been investigated far less than the well evaluated ventilation monitoring by functional EIT (f-EIT). To achieve progress in a-EIT we investigated 10 healthy volunteers in an upright sitting position by using a-EIT at normal gravity (1 g), weightlessness (0 g) and approx. double gravity (1.8 g) during parabolic flight manoeuvres. Lung resistivity in three thoracic planes was determined by a-EIT using a multiple-plane synchronised Goe-MF II EIT system. Tomograms of resistivity at end-expiration in normal spontaneous breathing were reconstructed by a modified SIRT algorithm. Local lung resistivity was determined separately for both lungs. The respective resistivity values at 1 g and 1.8 g before and after weightlessness show an almost reversible behaviour along the sequence of gravity changes with a tendency to be lower after occurrence of weightlessness. The results reveal not only the expected varying resistivity of lung tissue in cranio-caudal direction but also a clear difference in these cranio-caudal stratifications of local lung volume between the left and right lung. The resolution and stability of absolute EIT seem to be valid and expressive for future investigations of unilateral lung volume under different physiological and pathological conditions.

  4. Analysis of tidal breathing flow volume loops for automated lung-function diagnosis in infants.

    PubMed

    Leonhardt, Steffen; Ahrens, Peter; Kecman, Vojislav

    2010-08-01

    Lung-function analysis in the age group below 5 years has not yet found its way into clinical routine. One possible candidate for routine lung testing in this age group is the analysis of tidal breathing flow-volume (TBFV) loops, a technique that has not yet proven to be capable of detecting obstructive and other lung disorders at an early stage. We present a new set of mathematical features useful to analyze TBFV loops. These new features attempt to describe more complex properties of the loops, thus imitating medical judgment of the curves (e.g., "round," "triangular," etc.) in a "linguistic" manner. Furthermore, we introduce support vector machines (SVMs) as a method for automated classification of diseases. In a retrospective clinical trial on 195 spontaneously breathing infants aged 3 to 24 months, the discriminant power of individual features and the overall diagnostic performance of SVMs is investigated and compared with the results obtained with traditional Bayes' classifiers. We demonstrate that the proposed new features perform better in all examined disease groups and that depending on the disease, the classification error can be reduced by up to 50%. We conclude that TBFV loops may have a much stronger discriminant power than previously thought.

  5. Comparison of changes in hemodynamics between unilateral and bilateral lung volume reduction for pulmonary emphysema.

    PubMed

    Koizumi, K; Haraguchi, S; Akiyama, H; Hirata, T; Hirai, K; Mikami, I; Tanaka, S

    2001-10-01

    This study was aimed to compare changes in hemodynamics between unilateral (UL) or simultaneous bilateral (BL) lung volume reduction surgery (LVRS) for chronic obstructive lung disease. Sixteen patients underwent LVRS by stapler resection with neodymium: yttrium-alminum-garnet (Nd: YAG) laser ablation; five underwent BL-LVRS (four by median sternotomy and one by thoracoscopy) and 11 underwent UL-LVRS by thoracoscopy. Four patients had multiple bullae within pulmonary emphysema. At preoperation and 6, 12, 24, and 48 hours postoperatively, hemodynamics and right ventricular performance were evaluated. UL- and BL-LVRS reduced afterload of the right and left ventricle postoperatively. Although the pulmonary arterial resistance increased after surgery, the total pulmonary resistance decreased (p=0.001) in association with the reduced systemic vascular resistance (p=0.001). These reductions improved cardiopulmonary circulation, resulting in increased stroke volume and cardiac output (p=0.003). The right ventricular ejection fraction showed minimal change 48 hours postoperation. Two patients died of pneumonia caused by persistent air leakage. In conclusion, both the UL- and BL-LVRS showed similar effectiveness in terms of improvement in the systemic and cardiopulmonary circulation after LVRS, if there were no postoperative complications. We concluded that we had to reduce and repair the persistent air leakage after LVRS.

  6. Effects of swim training on lung volumes and inspiratory muscle conditioning.

    PubMed

    Clanton, T L; Dixon, G F; Drake, J; Gadek, J E

    1987-01-01

    Lung volumes and inspiratory muscle (IM) function tests were measured in 16 competitive female swimmers (age 19 +/- 1 yr) before and after 12 wk of swim training. Eight underwent additional IM training; the remaining eight were controls. Vital capacity (VC) increased 0.25 +/- 0.25 liters (P less than 0.01), functional residual capacity (FRC) increased 0.39 +/- 0.29 liters (P less than 0.001), and total lung capacity (TLC) increased 0.35 +/- 0.47 (P less than 0.025) in swimmers, irrespective of IM training. Residual volume (RV) did not change. Maximum inspiratory mouth pressure (PImax) measured at FRC changed -43 +/- 18 cmH2O (P less than 0.005) in swimmers undergoing IM conditioning and -29 +/- 25 (P less than 0.05) in controls. The time that 65% of prestudy PImax could be endured increased in IM trainers (P less than 0.001) and controls (P less than 0.05). All results were compared with similar IM training in normal females (age 21.1 +/- 0.8 yr) in which significant increases in PImax and endurance were observed in IM trainers only with no changes in VC, FRC, or TLC (Clanton et al., Chest 87: 62-66, 1985). We conclude that 1) swim training in mature females increases VC, TLC, and FRC with no effect on RV, and 2) swim training increases IM strength and endurance measured near FRC.

  7. Multidisciplinary collaborative gross tumour volume definition for lung cancer radiotherapy: a prospective study.

    PubMed

    Hollingdale, Abigail E; Roques, Tom W; Curtin, John; Martin, W M Craig; Horan, Gail; Barrett, Ann

    2011-12-07

    Variability in gross tumour volume (GTV) definition is a major source of systematic error in conformal radiotherapy. This prospective study assesses the role of multidisciplinary collaboration between oncologists and radiologists in defining lung cancer volumes. Twenty patients with non-small cell lung cancer due to receive three-dimensional conformal radiotherapy formed the study population. GTVs were defined by a radiologist (GTVrad) and an oncologist (GTVonc) using available clinical information and imaging. A collaborative meeting was then held to agree on a final, common GTV (GTVfin) to be used for treatment planning, and differences analysed. The collaboration changed the GTV in 19/20 patients with a total of 50 regions being edited. Changes made were categorized as (a) differentiation of tumour from atelectasis or ground glass shadowing, (b) separation of tumour from vasculature, and (c) defining mediastinal extent of tumour. Oncologists were more confident in the GTVfin than the GTVonc. The radiologist took longer to define the GTV than the oncologist. Real-time collaborative GTV definition by a radiologist and oncologist is practical and feasible. This approach allows specific areas of uncertainty to be categorized and focussed on, reducing systematic error in GTV definition. The physician's approach to risk and decision making for each patient may also play a role.

  8. Increased Lung Volume in Infants and Toddlers at High Compared to Low Altitude

    PubMed Central

    Llapur, Conrado J.; Martínez, Myriam R.; Caram, María Marta; Bonilla, Federico; Cabana, Celia; Yu, Zhansheng; Tepper, Robert S.

    2015-01-01

    Summary Children and adults residing at high altitude (HA) compared to low altitude (LA) have larger lung volumes; however, it is unknown whether this response to chronic hypoxia begins early in life. Our objective was to determine whether infants and toddlers at HA have larger lung volumes compared to infants and toddlers at LA. Oxygen saturation (SaO2), functional residual capacity (FRC), as well as serum levels of vascular endothelial growth factor (VEGF) and erythropoietin (EPO) were measured in infants and toddlers from HA (N = 50; 3,440 m) and LA (N = 35; 440 m). There were no significant differences in somatic size for HA and LA subjects; however, HA subjects had significantly lower SaO2 (88.5% vs. 96.7%; P < 0.0001). Subjects at HA had significantly greater FRC compared to subjects at LA (group mean: 209 and 157 ml; P < 0.0001), adjusting for body length. Male infants at HA had a significantly greater FRC compared to males at LA (57 ml; P-value < 0.001); however, the increase in FRC for females at HA compared to LA was not significant (20 ml; P-value = 0.101). VEGF and EPO were significantly higher for subjects at HA compared to LA with no gender differences. In summary, infants and toddlers at HA have lower oxygen saturations, higher serum levels of VEGF and EPO, and higher FRC compared to subjects at LA; however, chronic hypoxia appears to generate a more robust response in lung growth in male compared to female infants early in life. PMID:23401418

  9. Effects of frequency, tidal volume, and lung volume on CO2 elimination in dogs by high frequency (2-30 Hz), low tidal volume ventilation.

    PubMed Central

    Slutsky, A S; Kamm, R D; Rossing, T H; Loring, S H; Lehr, J; Shapiro, A H; Ingram, R H; Drazen, J M

    1981-01-01

    Recent studies have shown that effective pulmonary ventilation is possible with tidal volumes (VT) less than the anatomic dead-space if the oscillatory frequency (f) is sufficiently large. We systematically studied the effect on pulmonary CO2 elimination (VCO2) of varying f (2-30 Hz) and VT (1-7 ml/kg) as well as lung volume (VL) in 13 anesthetized, paralyzed dogs in order to examine the contribution of those variables that are thought to be important in determining gas exchange by high frequency ventilation. All experiments were performed when the alveolar PCO2 was 40 +/- 1.5 mm Hg. In all studies, VCO2 increased monotonically with f at constant VT. We quantitated the effects of f and VT on VCO2 by using the dimensionless equation VCO2/VOSC = a(VT/VTo)b(f/fo)c where: VOSC = f X VT, VTo = mean VT, fo = mean f and a, b, c, are constants obtained by multiple regression. The mean values of a, b, and c for all dogs were 2.12 X 10(-3), 0.49, and 0.08, respectively. The most important variable in determining VCO2 was VOSC; however, there was considerable variability among dogs in the independent effect of VT and f on VCO2, with a doubling of VT at a constant VOSC causing changes in VCO2 ranging from -13 to +110% (mean = +35%). Increasing VL from functional residual capacity (FRC) to the lung volume at an airway opening minus body surface pressure of 25 cm H2O had no significant effect on VCO2. PMID:6798071

  10. Lung recruitment maneuver during volume guarantee ventilation of preterm infants with acute respiratory distress syndrome.

    PubMed

    Castoldi, Francesca; Daniele, Irene; Fontana, Paola; Cavigioli, Francesco; Lupo, Enrica; Lista, Gianluca

    2011-08-01

    Preterm infants need the achievement of adequate lung volume. Lung recruitment maneuver (LRM) is applied during high-frequency oscillatory ventilation. We investigated the effect of an LRM with positive end-expiratory pressure (PEEP) on oxygenation and outcomes in infants conventionally ventilated for respiratory distress syndrome (RDS). Preterm infants in assisted controlled ventilation+volume guarantee for RDS after surfactant randomly received an LRM (group A) or did not (group B). LRM entailed increments of 0.2 cm H (2)O PEEP every 5 minutes, until fraction of inspired oxygen (Fi O(2))=0.25. Then PEEP was reduced and the lung volume was set on the deflation limb of the pressure/volume curve. When saturation of peripheral oxygen fell and Fi O(2) rose, we reincremented PEEP until Sp O(2) became stable. Group A ( N=10) and group B ( N=10) infants were similar: gestational age 25 ± 2 versus 25 ± 2 weeks; body weight 747 ± 233 versus 737 ± 219 g; clinical risk index for babies 9.8 versus 8.1; initial Fi O(2) 56 ± 24 versus 52 ± 21, respectively. LRM began at 86 ± 69 minutes of age and lasted for 61 ± 18 minutes. Groups A and B showed different max PEEP during the first 12 hours of life (6.1 ± 0.3 versus 5.3 ± 0.3 cm H (2)O, P=0.00), time to lowest Fi O(2) (94 ± 24 versus 435 ± 221 minutes; P=0.000) and O(2) dependency (29 ± 12 versus 45 ± 17 days; P=0.04). No adverse events and no differences in the outcomes were observed. LRM led to the earlier lowest Fi O(2) of the first 12 hours of life and a shorter O (2) dependency.

  11. Expiratory tidal volume displayed on Bird 8400 STi can exceed the preset tidal volume due to cardiogenic oscillation: a lung model study.

    PubMed

    Imanaka, Hideaki; Takeuchi, Muneyuki; Tachibana, Kazuya; Nishimura, Masaji

    2004-01-01

    We noticed that monitored tidal volumes often exceeded preset tidal volumes in patients with large cardiogenic oscillation. To investigate whether triggering modes affect this discrepancy, we simulated cardiogenic oscillation of 90 breaths/min in a lung model, which was ventilated with a Bird 8400 STi ventilator (Bird, Palm Springs, CA, USA). The magnitude of cardiogenic oscillation was defined as peak expiratory flow fluctuation at the lung model. Two respiratory rates (5 and 10 breaths/min) and two triggering modes (flow-triggering and pressure-triggering) were applied, while tidal volume was set at 500 ml. We recorded tidal volume on a ventilator monitor and calculated the discrepancy from the set tidal volume. We also measured fluctuation in flow and airway opening pressure created by cardiogenic oscillation. During flow-triggering, larger flow fluctuation and smaller airway pressure fluctuation were observed compared with during pressure-triggering. During flow-triggering, the discrepancy between monitored tidal volume and set value ranged from 0 to +327 ml at 5 breaths/min, and from 0 to +105 ml at 10 breaths/min. There was a linear correlation between the magnitude of cardiogenic oscillation and the overestimation of tidal volume. By contrast, during pressure-triggering, the discrepancy was small. In conclusion, tidal volume is overestimated during flow-triggering but not during pressure-triggering when cardiogenic oscillation is large.

  12. Assessment of regional non-linear tissue deformation and air volume change of human lungs via image registration.

    PubMed

    Jahani, Nariman; Yin, Youbing; Hoffman, Eric A; Lin, Ching-Long

    2014-05-07

    We evaluate the non-linear characteristics of the human lung via image registration-derived local variables based on volumetric multi-detector-row computed tomographic (MDCT) lung image data of six normal human subjects acquired at three inflation levels: 20% of vital capacity (VC), 60% VC and 80% VC. Local variables include Jacobian (ratio of volume change) and maximum shear strain for assessment of lung deformation, and air volume change for assessment of air distribution. First, the variables linearly interpolated between 20% and 80% VC images to reflect deformation from 20% to 60% VC are compared with those of direct registration of 20% and 60% VC images. The result shows that the linearly-interpolated variables agree only qualitatively with those of registration (P<0.05). Then, a quadratic (or linear) interpolation is introduced to link local variables to global air volumes of three images (or 20% and 80% VC images). A sinusoidal breathing waveform is assumed for assessing the time rate of change of these variables. The results show significant differences between two-image and three-image results (P<0.05). The three-image results for the whole lung indicate that the peak of the maximum shear rate occurs at about 37% of the maximum volume difference between 20% and 80% VC, while the peaks for the Jacobian and flow rate occur at 50%. This is in agreement with accepted physiology whereby lung tissues deform more at lower lung volumes due to lower elasticity and greater compliance. Furthermore, the three-image results show that the upper and middle lobes, even in the recumbent, supine posture, reach full expansion earlier than the lower lobes.

  13. Absolute Zero

    NASA Astrophysics Data System (ADS)

    Donnelly, Russell J.; Sheibley, D.; Belloni, M.; Stamper-Kurn, D.; Vinen, W. F.

    2006-12-01

    Absolute Zero is a two hour PBS special attempting to bring to the general public some of the advances made in 400 years of thermodynamics. It is based on the book “Absolute Zero and the Conquest of Cold” by Tom Shachtman. Absolute Zero will call long-overdue attention to the remarkable strides that have been made in low-temperature physics, a field that has produced 27 Nobel Prizes. It will explore the ongoing interplay between science and technology through historical examples including refrigerators, ice machines, frozen foods, liquid oxygen and nitrogen as well as much colder fluids such as liquid hydrogen and liquid helium. A website has been established to promote the series: www.absolutezerocampaign.org. It contains information on the series, aimed primarily at students at the middle school level. There is a wealth of material here and we hope interested teachers will draw their student’s attention to this website and its substantial contents, which have been carefully vetted for accuracy.

  14. An automated method for measuring static pressure-volume curves of the respiratory system and its application in healthy lungs and after lung damage by oleic acid infusion.

    PubMed

    Zhao, Y; Rees, S E; Kjaergaard, S; Smith, B W; Larsson, A; Andreassen, S

    2007-03-01

    Elastic pressure/volume (PV) curves of the respiratory system have attracted increasing interest, because they may be helpful to optimize ventilator settings in patients undergoing mechanical ventilation. Clinically applicable methods need to be fast, use routinely available equipment, draw the inspiratory and expiratory PV curve limbs, separate the resistive and viscoelastic properties of the respiratory system from the elastic properties, and provide reproducible measurements. This paper presents a computer-controlled method for rapid measurements of static PV curves using a long inflation-deflation with pauses, and its evaluation in six pigs before and after lung damage caused by oleic acid. The method is fast, i.e. 20.5 +/- 1.9 s (mean +/- SD) in healthy lungs and 17.7 +/- 4.1 s in diseased lungs, this including inspiratory and expiratory pauses of 1.1 s duration. In addition the only equipment used was a clinical ventilator and a PC. For healthy and damaged lungs expiratory PV curve limbs were very reproducible and were at higher volume than the inspiratory limbs, indicating hysteresis. For damaged lungs inspiratory PV limbs were reproducible. For healthy lungs the inspiratory limbs were reproducible but only after the first inflation-deflation. It is possible that during the first inflation alveoli are recruited which are not derecruited on deflation, shifting the inspiratory limb of the PV curve. The paused long inflation-deflation technique provides a quick, automated measurement of static PV curves on both inspiratory and expiratory limbs using routinely available equipment in the intensive care unit.

  15. Quantifying the roles of tidal volume and PEEP in the pathogenesis of ventilator-induced lung injury.

    PubMed

    Seah, Adrian S; Grant, Kara A; Aliyeva, Minara; Allen, Gilman B; Bates, Jason H T

    2011-05-01

    Management of patients with acute lung injury (ALI) rests on achieving a balance between the gas exchanging benefits of mechanical ventilation and the exacerbation of tissue damage in the form of ventilator-induced lung injury (VILI). Optimizing this balance requires an injury cost function relating injury progression to the measurable pressures, flows, and volumes delivered during mechanical ventilation. With this in mind, we mechanically ventilated naive, anesthetized, paralyzed mice for 4 h using either a low or high tidal volume (Vt) with either moderate or zero positive end-expiratory pressure (PEEP). The derecruitability of the lung was assessed every 15 min in terms of the degree of increase in lung elastance occurring over 3 min following a recruitment maneuver. Mice could be safely ventilated for 4 h with either a high Vt or zero PEEP, but when both conditions were applied simultaneously the lung became increasingly unstable, demonstrating worsening injury. We were able to mimic these data using a computational model of dynamic recruitment and derecruitment that simulates the effects of progressively increasing surface tension at the air-liquid interface, suggesting that the VILI in our animal model progressed via a vicious cycle of alveolar leak, degradation of surfactant function, and increasing tissue stress. We thus propose that the task of ventilating the injured lung is usefully understood in terms of the Vt-PEEP plane. Within this plane, non-injurious combinations of Vt and PEEP lie within a "safe region", the boundaries of which shrink as VILI develops.

  16. Lung volume recruitment acutely increases respiratory system compliance in individuals with severe respiratory muscle weakness

    PubMed Central

    Molgat-Seon, Yannick; Hannan, Liam M.; Dominelli, Paolo B.; Peters, Carli M.; Fougere, Renee J.; McKim, Douglas A.; Sheel, A. William

    2017-01-01

    The aim of the present study was to determine whether lung volume recruitment (LVR) acutely increases respiratory system compliance (Crs) in individuals with severe respiratory muscle weakness (RMW). Individuals with RMW resulting from neuromuscular disease or quadriplegia (n=12) and healthy controls (n=12) underwent pulmonary function testing and the measurement of Crs at baseline, immediately after, 1 h after and 2 h after a single standardised session of LVR. The LVR session involved 10 consecutive supramaximal lung inflations with a manual resuscitation bag to the highest tolerable mouth pressure or a maximum of 50 cmH2O. Each LVR inflation was followed by brief breath-hold and a maximal expiration to residual volume. At baseline, individuals with RMW had lower Crs than controls (37±5 cmH2O versus 109±10 mL·cmH2O−1, p<0.001). Immediately after LVR, Crs increased by 39.5±9.8% to 50±7 mL·cmH2O−1 in individuals with RMW (p<0.05), while no significant change occurred in controls (p=0.23). At 1 h and 2 h post-treatment, there were no within-group differences in Crs compared to baseline (all p>0.05). LVR had no significant effect on measures of pulmonary function at any time point in either group (all p>0.05). During inflations, mean arterial pressure decreased significantly relative to baseline by 10.4±2.8 mmHg and 17.3±3.0 mmHg in individuals with RMW and controls, respectively (both p<0.05). LVR acutely increases Crs in individuals with RMW. However, the high airway pressures during inflations cause reductions in mean arterial pressure that should be considered when applying this technique. PMID:28326313

  17. Improved Health-Related Quality of Life After Lung Volume Reduction Surgery and Pulmonary Rehabilitation

    PubMed Central

    2009-01-01

    Purpose: It has been hypothesized that lung volume reduction surgery (LVRS) and pulmonary rehabilitation improve health-related quality of life (HRQOL). The purpose of this study was to test the hypothesis by examining the long-term functional consequences and general health status of patients with emphysema who have undergone LVRS and pulmonary rehabilitation. Methods: Forty-nine subjects with severe emphysema, aged 51 to 84 years old, post-LVRS and pulmonary rehabilitation participated in this study. Subjects reported changes in physical and mental domains on the Medical Outcomes Study 36-Item Short Form Health Survey (MOS SF-36) over 3 time periods: prior to surgery, 6 months postsurgery, and 18 months postsurgery. The population as a whole was studied and both gender and age were analyzed as subsets. Subjects participated in an intensive 2-week (10 daily sessions) pulmonary rehabilitation program following LVRS. Results: Subjects showed significant improvements in both the physical and mental component summaries at Time 2 (3 months post-LVRS through 6 months post-LVRS) and Time 3 (12 months post-LVRS through 18 months post-LVRS) when compared to Time 1 (pre-LVRS). On the mental component summary scale, subjects younger than 65 years old had significant improvement compared to subjects 65 years and older at Time 3 (P < .05). Women significantly improved more than men at Time 3 on the physical component summary scale (P < .05). Conclusions: Lung volume reduction surgery and 2 weeks (10 daily sessions) of intensive pulmonary rehabilitation appears to improve HRQOL in people with emphysema up to at least 18 months postsurgery. What these data further suggest is that even after declines in health, women can improve HRQOL later in life, and that greater focus should be given to the emotional needs of our older patients. PMID:20467519

  18. Short-term influences of lung volume reduction surgery on the diaphragm in emphysematous hamsters.

    PubMed

    Lewis, Michael I; Fournier, Mario; Da, Xiaoyu; Li, Hongmei; Mosenifar, Zab; McKenna, Robert J; Cohen, Arthur H

    2004-10-01

    With emphysema, diaphragm length adaptation results in shortened fibers. We hypothesize that passive diaphragm stretch occurring acutely after lung volume reduction surgery (LVRS) results in fiber injury. Bilateral LVRS was performed in emphysematous hamsters. Studies were performed 1 (D1) and 4 (D4) days after LVRS, and compared with sham-treated groups. Sarcolemmal rupture was evident in 10.9% of fibers in LVRS-D1 and reduced to 1.6% in LVRS-D4. Ultrastructural analysis revealed focal abnormalities in both LVRS-D1 and LVRS-D4 animals in over one-third of fibers. Myofibrillar disruption was not observed in sham-treated animals. Diaphragm insulin-like growth factor-I (IGF-I) was increased in LVRS-D4 compared with other emphysematous groups. Increased IGF-I immunoreactivity was localized to types IIA and I fibers. The abundance of the splice variant of IGF-I mRNA sensitive to muscle stretch (IGF-IEb) increased 3.2-fold in LVRS D-4 diaphragms, compared with emphysema-sham animals. The main form of IGF-I mRNA was unchanged. Marked force deficit was observed in the LVRS-D1 diaphragm, compared with emphysema-sham and emphysema (no surgery) animals. These data highlight a markedly compromised ventilatory pump acutely after LVRS. Acute fiber stretch predisposes to muscle fiber injury and may also be a necessary mechanotransductive stimulus for fiber remodeling as the diaphragm adapts to reduced lung volume.

  19. Beam-specific planning volumes for scattered-proton lung radiotherapy.

    PubMed

    Flampouri, S; Hoppe, B S; Slopsema, R L; Li, Z

    2014-08-21

    This work describes the clinical implementation of a beam-specific planning treatment volume (bsPTV) calculation for lung cancer proton therapy and its integration into the treatment planning process. Uncertainties incorporated in the calculation of the bsPTV included setup errors, machine delivery variability, breathing effects, inherent proton range uncertainties and combinations of the above. Margins were added for translational and rotational setup errors and breathing motion variability during the course of treatment as well as for their effect on proton range of each treatment field. The effect of breathing motion and deformation on the proton range was calculated from 4D computed tomography data. Range uncertainties were considered taking into account the individual voxel HU uncertainty along each proton beamlet. Beam-specific treatment volumes generated for 12 patients were used: a) as planning targets, b) for routine plan evaluation, c) to aid beam angle selection and d) to create beam-specific margins for organs at risk to insure sparing. The alternative planning technique based on the bsPTVs produced similar target coverage as the conventional proton plans while better sparing the surrounding tissues. Conventional proton plans were evaluated by comparing the dose distributions per beam with the corresponding bsPTV. The bsPTV volume as a function of beam angle revealed some unexpected sources of uncertainty and could help the planner choose more robust beams. Beam-specific planning volume for the spinal cord was used for dose distribution shaping to ensure organ sparing laterally and distally to the beam.

  20. Beam-specific planning volumes for scattered-proton lung radiotherapy

    NASA Astrophysics Data System (ADS)

    Flampouri, S.; Hoppe, B. S.; Slopsema, R. L.; Li, Z.

    2014-08-01

    This work describes the clinical implementation of a beam-specific planning treatment volume (bsPTV) calculation for lung cancer proton therapy and its integration into the treatment planning process. Uncertainties incorporated in the calculation of the bsPTV included setup errors, machine delivery variability, breathing effects, inherent proton range uncertainties and combinations of the above. Margins were added for translational and rotational setup errors and breathing motion variability during the course of treatment as well as for their effect on proton range of each treatment field. The effect of breathing motion and deformation on the proton range was calculated from 4D computed tomography data. Range uncertainties were considered taking into account the individual voxel HU uncertainty along each proton beamlet. Beam-specific treatment volumes generated for 12 patients were used: a) as planning targets, b) for routine plan evaluation, c) to aid beam angle selection and d) to create beam-specific margins for organs at risk to insure sparing. The alternative planning technique based on the bsPTVs produced similar target coverage as the conventional proton plans while better sparing the surrounding tissues. Conventional proton plans were evaluated by comparing the dose distributions per beam with the corresponding bsPTV. The bsPTV volume as a function of beam angle revealed some unexpected sources of uncertainty and could help the planner choose more robust beams. Beam-specific planning volume for the spinal cord was used for dose distribution shaping to ensure organ sparing laterally and distally to the beam.

  1. Lung volume quantified by MRI reflects extracellular-matrix deposition and altered pulmonary function in bleomycin models of fibrosis: effects of SOM230.

    PubMed

    Egger, Christine; Gérard, Christelle; Vidotto, Nella; Accart, Nathalie; Cannet, Catherine; Dunbar, Andrew; Tigani, Bruno; Piaia, Alessandro; Jarai, Gabor; Jarman, Elizabeth; Schmid, Herbert A; Beckmann, Nicolau

    2014-06-15

    Idiopathic pulmonary fibrosis is a progressive and lethal disease, characterized by loss of lung elasticity and alveolar surface area, secondary to alveolar epithelial cell injury, reactive inflammation, proliferation of fibroblasts, and deposition of extracellular matrix. The effects of oropharyngeal aspiration of bleomycin in Sprague-Dawley rats and C57BL/6 mice, as well as of intratracheal administration of ovalbumin to actively sensitized Brown Norway rats on total lung volume as assessed noninvasively by magnetic resonance imaging (MRI) were investigated here. Lung injury and volume were quantified by using nongated or respiratory-gated MRI acquisitions [ultrashort echo time (UTE) or gradient-echo techniques]. Lung function of bleomycin-challenged rats was examined additionally using a flexiVent system. Postmortem analyses included histology of collagen and hydroxyproline assays. Bleomycin induced an increase of MRI-assessed total lung volume, lung dry and wet weights, and hydroxyproline content as well as collagen amount. In bleomycin-treated rats, gated MRI showed an increased volume of the lung in the inspiratory and expiratory phases of the respiratory cycle and a temporary decrease of tidal volume. Decreased dynamic lung compliance was found in bleomycin-challenged rats. Bleomycin-induced increase of MRI-detected lung volume was consistent with tissue deposition during fibrotic processes resulting in decreased lung elasticity, whereas influences by edema or emphysema could be excluded. In ovalbumin-challenged rats, total lung volume quantified by MRI remained unchanged. The somatostatin analog, SOM230, was shown to have therapeutic effects on established bleomycin-induced fibrosis in rats. This work suggests MRI-detected total lung volume as readout for tissue-deposition in small rodent bleomycin models of pulmonary fibrosis.

  2. Automated localization and segmentation of lung tumor from PET-CT thorax volumes based on image feature analysis.

    PubMed

    Cui, Hui; Wang, Xiuying; Feng, Dagan

    2012-01-01

    Positron emission tomography - computed tomography (PET-CT) plays an essential role in early tumor detection, diagnosis, staging and treatment. Automated and more accurate lung tumor detection and delineation from PET-CT is challenging. In this paper, on the basis of quantitative analysis of contrast feature of PET volume in SUV (standardized uptake value), our method firstly automatically localized the lung tumor. Then based on analysing the surrounding CT features of the initial tumor definition, our decision strategy determines the tumor segmentation from CT or from PET. The algorithm has been validated on 20 PET-CT studies involving non-small cell lung cancer (NSCLC). Experimental results demonstrated that our method was able to segment the tumor when adjacent to mediastinum or chest wall, and the algorithm outperformed the other five lung segmentation methods in terms of overlapping measure.

  3. Space density distribution of galaxies in the absolute magnitude - rotation velocity plane: a volume-complete Tully-Fisher relation from CALIFA stellar kinematics

    NASA Astrophysics Data System (ADS)

    Bekeraité, S.; Walcher, C. J.; Falcón-Barroso, J.; Garcia Lorenzo, B.; Lyubenova, M.; Sánchez, S. F.; Spekkens, K.; van de Ven, G.; Wisotzki, L.; Ziegler, B.; Aguerri, J. A. L.; Barrera-Ballesteros, J.; Bland-Hawthorn, J.; Catalán-Torrecilla, C.; García-Benito, R.

    2016-10-01

    We measured the distribution in absolute magnitude - circular velocity space for a well-defined sample of 199 rotating galaxies of the Calar Alto Legacy Integral Field Area Survey (CALIFA) using their stellar kinematics. Our aim in this analysis is to avoid subjective selection criteria and to take volume and large-scale structure factors into account. Using stellar velocity fields instead of gas emission line kinematics allows including rapidly rotating early-type galaxies. Our initial sample contains 277 galaxies with available stellar velocity fields and growth curve r-band photometry. After rejecting 51 velocity fields that could not be modelled because of the low number of bins, foreground contamination, or significant interaction, we performed Markov chain Monte Carlo modelling of the velocity fields, from which we obtained the rotation curve and kinematic parameters and their realistic uncertainties. We performed an extinction correction and calculated the circular velocity vcirc accounting for the pressure support of a given galaxy. The resulting galaxy distribution on the Mr-vcirc plane was then modelled as a mixture of two distinct populations, allowing robust and reproducible rejection of outliers, a significant fraction of which are slow rotators. The selection effects are understood well enough that we were able to correct for the incompleteness of the sample. The 199 galaxies were weighted by volume and large-scale structure factors, which enabled us to fit a volume-corrected Tully-Fisher relation (TFR). More importantly, we also provide the volume-corrected distribution of galaxies in the Mr-vcirc plane, which can be compared with cosmological simulations. The joint distribution of the luminosity and circular velocity space densities, representative over the range of -20 > Mr > -22 mag, can place more stringent constraints on the galaxy formation and evolution scenarios than linear TFR fit parameters or the luminosity function alone. Galaxies main

  4. Is lung volume reduction surgery effective in the treatment of advanced emphysema?

    PubMed

    Zahid, Imran; Sharif, Sumera; Routledge, Tom; Scarci, Marco

    2011-03-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was whether lung volume reduction surgery (LVRS) might be superior to medical treatment in the management of patients with severe emphysema. Overall 497 papers were found using the reported search, of which 12 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results are tabulated. We conclude that LVRS produces superior patient outcomes compared to medical treatment in terms of exercise capacity, lung function, quality of life and long-term (>1 year postoperative) survival. A large proportion of the best evidence on this topic is based on analysis of the National Emphysema Treatment Trial (NETT). Seven studies compared LVRS to medical treatment alone (MTA) using data generated by the NETT trial. They found higher quality of life scores (45.3 vs. 27.5, P<0.001), improved maximum ventilation (32.8 vs. 29.6 l/min, P=0.001) and lower exacerbation rate per person-year (0.27 vs. 0.37%, P=0.0005) with LVRS than MTA. Mortality rates for LVRS were greater up to one year (P=0.01), equivalent by three years (P=0.15) and lower after four years (P=0.06) postoperative compared to MTA. Patients with upper-lobe-predominant disease and low exercise capacity (0.36 vs. 0.54, P=0.003) benefited the most from undergoing LVRS rather than MTA in terms of probability of death at five years compared to patients with non-upper-lobe disease (0.38 vs. 0.45, P=0.03) or upper-lobe-disease with high exercise capacity (0.33 vs. 0.38, P=0.32). Five studies compared LVRS to MTA using data independent from the NETT trial. They found greater six-minute walking distances (433 vs. 300 m, P<0.002), improved total lung capacity (18.8 vs. 7.9% predicted, P<0.02) and quality of life scores (47 vs. 23.2, P<0.05) with LVRS compared to MTA. Even though LVRS has a much

  5. Localization Accuracy of the Clinical Target Volume During Image-Guided Radiotherapy of Lung Cancer

    SciTech Connect

    Hugo, Geoffrey D.; Weiss, Elisabeth; Badawi, Ahmed; Orton, Matthew

    2011-10-01

    Purpose: To evaluate the position and shape of the originally defined clinical target volume (CTV) over the treatment course, and to assess the impact of gross tumor volume (GTV)-based online computed tomography (CT) guidance on CTV localization accuracy. Methods and Materials: Weekly breath-hold CT scans were acquired in 17 patients undergoing radiotherapy. Deformable registration was used to propagate the GTV and CTV from the first weekly CT image to all other weekly CT images. The on-treatment CT scans were registered rigidly to the planning CT scan based on the GTV location to simulate online guidance, and residual error in the CTV centroids and borders was calculated. Results: The mean GTV after 5 weeks relative to volume at the beginning of treatment was 77% {+-} 20%, whereas for the prescribed CTV, it was 92% {+-} 10%. The mean absolute residual error magnitude in the CTV centroid position after a GTV-based localization was 2.9 {+-} 3.0 mm, and it varied from 0.3 to 20.0 mm over all patients. Residual error of the CTV centroid was associated with GTV regression and anisotropy of regression during treatment (p = 0.02 and p = 0.03, respectively; Spearman rank correlation). A residual error in CTV border position greater than 2 mm was present in 77% of patients and 50% of fractions. Among these fractions, residual error of the CTV borders was 3.5 {+-} 1.6 mm (left-right), 3.1 {+-} 0.9 mm (anterior-posterior), and 6.4 {+-} 7.5 mm (superior-inferior). Conclusions: Online guidance based on the visible GTV produces substantial error in CTV localization, particularly for highly regressing tumors. The results of this study will be useful in designing margins for CTV localization or for developing new online CTV localization strategies.

  6. Interventional pulmonology for asthma and emphysema: bronchial thermoplasty and bronchoscopic lung volume reduction.

    PubMed

    Miller, Russell J; Murgu, Septimiu D

    2014-12-01

    Emphysema and asthma are responsible for economic and social burden. Altering the natural course of these diseases is a field of intense research. The National Emphysema Treatment Trial showed that lung volume reduction surgery (LVRS) could significantly reduce both morbidity and mortality in properly selected patients. LVRS is seldom performed, however, due to the high morbidity associated with the surgery. Numerous bronchoscopic interventions have been introduced with the goal of providing the clinical benefits of LVRS without the surgical complications. Thus far, these modalities have not produced the results once hoped. However, through active modification of both technique and patient selection, the role of minimally invasive modalities in the treatment of emphysema continues to evolve. Bronchial thermoplasty (BT) is a method of delivering controlled heat to airway mucosa with the goal of reducing airway smooth muscle mass and hence bronchoconstriction. In patients suffering from asthma who cannot achieve control with standard medical care, BT has been shown to be safe and improves symptoms, with long lasting benefit. BT does not seem to affect traditional markers of asthma severity such as forced expiratory volume in 1 second and questions remain regarding proper patient selection for this therapy and its true physiologic effects. This article is a review of bronchoscopic modalities for emphysema and asthma.

  7. Absolute Summ

    NASA Astrophysics Data System (ADS)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  8. Effect of pattern and severity of respiratory muscle weakness on carbon monoxide gas transfer and lung volumes.

    PubMed

    Hart, N; Cramer, D; Ward, S P; Nickol, A H; Moxham, J; Polkey, M I; Pride, N B

    2002-10-01

    In clinical practice, an elevated carbon monoxide (CO) transfer coefficient (KCO) and restrictive ventilatory defect are taken as features of respiratory muscle weakness (RMW). However, the authors hypothesised that both pattern and severity of RMW effect gas transfer and lung volumes. Measurements of CO transfer and lung volumes were performed in patients with isolated diaphragm weakness (n=10), inspiratory muscle weakness (n=12), combined inspiratory and expiratory muscle weakness (n=5) and healthy controls (n=6). Patients with diaphragm weakness and inspiratory muscle weakness had reduced total lung capacity (TLC) (83.6% predicted and 68.9% pred, respectively), functional residual capacity (FRC) (83.9% pred and 83.6% pred) and transfer factor of the lung for CO (TL,CO) (86.2% pred and 66.2% pred) with increased KCO (114.1% pred and 130.2% pred). Patients with combined inspiratory and expiratory muscle weakness had reduced TLC (80.9% pred) but increased FRC (109.9% pred) and RV (157.4% pred) with decreased TL,CO (58.0% pred) and KCO (85.5% pred). In patients with diaphragm weakness, the increase in carbon monoxide transfer coefficient was similar to that of normal subjects when alveolar volume was reduced. However, the increase in carbon monoxide transfer coefficient in inspiratory muscle weakness was often less than expected, while in combined inspiratory and expiratory muscle weakness, the carbon monoxide transfer coefficient was normal/reduced despite further reductions in alveolar volume, which may indicate subtle abnormalities of the lung parenchyma or pulmonary vasculature. Thus, this study demonstrates the limitations of using carbon monoxide transfer coefficient in the diagnosis of respiratory muscle weakness, particularly if no account is taken of the alveolar volume at which the carbon monoxide transfer coefficient is made.

  9. Maximum-Intensity Volumes for Fast Contouring of Lung Tumors Including Respiratory Motion in 4DCT Planning

    SciTech Connect

    Rietzel, Eike Liu, Arthur K.; Chen, George T.Y.; Choi, Noah C.

    2008-07-15

    Purpose: To assess the accuracy of maximum-intensity volumes (MIV) for fast contouring of lung tumors including respiratory motion. Methods and Materials: Four-dimensional computed tomography (4DCT) data of 10 patients were acquired. Maximum-intensity volumes were constructed by assigning the maximum Hounsfield unit in all CT volumes per geometric voxel to a new, synthetic volume. Gross tumor volumes (GTVs) were contoured on all CT volumes, and their union was constructed. The GTV with all its respiratory motion was contoured on the MIV as well. Union GTVs and GTVs including motion were compared visually. Furthermore, planning target volumes (PTVs) were constructed for the union of GTVs and the GTV on MIV. These PTVs were compared by centroid position, volume, geometric extent, and surface distance. Results: Visual comparison of GTVs demonstrated failure of the MIV technique for 5 of 10 patients. For adequate GTV{sub MIV}s, differences between PTVs were <1.0 mm in centroid position, 5% in volume, {+-}5 mm in geometric extent, and {+-}0.5 {+-} 2.0 mm in surface distance. These values represent the uncertainties for successful MIV contouring. Conclusion: Maximum-intensity volumes are a good first estimate for target volume definition including respiratory motion. However, it seems mandatory to validate each individual MIV by overlaying it on a movie loop displaying the 4DCT data and editing it for possible inadequate coverage of GTVs on additional 4DCT motion states.

  10. Systems for Lung Volume Standardization during Static and Dynamic MDCT-based Quantitative Assessment of Pulmonary Structure and Function

    PubMed Central

    Fuld, Matthew K.; Grout, Randall; Guo, Junfeng; Morgan, John H.; Hoffman, Eric A.

    2013-01-01

    Rationale and Objectives Multidetector-row Computed Tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics) and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breath-hold at a standardized volume. Materials and Methods A computer monitored turbine-based flow meter system was developed to control patient breath-holds and facilitate static imaging at fixed percentages of the vital capacity. Due to calibration challenges with gas density changes during multi-breath xenon-CT an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. Results The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was −9 ml (−169, 151); for TLC alone 6 ml (−164, 177); for FRC alone, −23 ml (−172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject non-compliance with verbal instruction and gas leaks around the mouthpiece. Conclusion We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon-CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multi-breath wash-in xenon-CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon-CT method for assessing regional lung function, while not

  11. A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography.

    PubMed

    Aristophanous, Michalis; Penney, Bill C; Martel, Mary K; Pelizzari, Charles A

    2007-11-01

    The increased interest in 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an "analysis region" to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of the

  12. A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography

    SciTech Connect

    Aristophanous, Michalis; Penney, Bill C.; Martel, Mary K.; Pelizzari, Charles A.

    2007-11-15

    The increased interest in {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an 'analysis region' to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of

  13. Absolute Photometry

    NASA Astrophysics Data System (ADS)

    Hartig, George

    1990-12-01

    The absolute sensitivity of the FOS will be determined in SV by observing 2 stars at 3 epochs, first in 3 apertures (1.0", 0.5", and 0.3" circular) and then in 1 aperture (1.0" circular). In cycle 1, one star, BD+28D4211 will be observed in the 1.0" aperture to establish the stability of the sensitivity and flat field characteristics and improve the accuracy obtained in SV. This star will also be observed through the paired apertures since these are not calibrated in SV. The stars will be observed in most detector/grating combinations. The data will be averaged to form the inverse sensitivity functions required by RSDP.

  14. SU-E-J-78: Internal Target Volume Delineation for Lung Tumors in Patients Treated with Robotic Radiosurgery

    SciTech Connect

    Descovich, M; Pinnaduwage, D; Kirby, N; Gottschalk, A; Yom, S; Pouliot, J; Braunstein, S

    2014-06-01

    Purpose: To compare different approaches for Internal Target Volume (ITV) delineation for patients treated with fiducial-free robotic radiosurgery for primary and metastatic lung tumors. Methods: Ten patients undergoing Lung-Optimized Treatment (LOT) for robotic radiosurgery were imaged with inhale and exhale breath-hold CT scans and 8-phase 4DCT scan. We evaluated the differences in internal target volume (ITV) delineated using three approaches: 1) maximum intensity projection (MIP) images reconstructed from 4DCT scan (ITV-MIP); 2) linear interpolation of Gross Tumor Volumes (GTV) segmented on inhale and exhale breath-hold scans (ITV-BH); 3) linear interpolation of GTV segmented on inhale and exhale phases of 4DCT scan (ITV-2Phase). All contours were independently generated by the same radiation oncologist using lung window settings. Patients had ITV-MIP volumes ranging from 1.5 to 146.9 cc (mean 36.8 cc) located in various parts of the lung. Volume overlap and matching index (MI) were calculated and compared. The MI between two volumes was defined as the ratio of their intersection to their union. MI of 1 indicates the volumes are identical; MI of 0 indicates that there is no overlap. Results: The three approaches generated very different results. The average (SD) MI for ITV-MIP and ITV-BH was 0.52 (0.24); for ITV-MIP and ITV-2Phase it was 0.69 (0.13); and for ITV-BH and ITV-2Phase was 0.57 (0.21), (ANOVA, p=0.16). Relative to the ITV-MIP, the percentage of volume overlap was 72% (26%) and 90% (7%) for ITV-BH and ITV-2Phase, respectively (t-test, p=0.05). Conclusion: Differences between ITV-BH and ITV-MIP are due to inconsistent lung filling at breath-hold and nonlinear tumor motion. Therefore, methods to check breath-hold scanning against regular patient breathing patterns should be developed. Whenever possible, ITV-BH generated by the LOT workflow should be verified by 4DCT data.

  15. Assessment of interpatient heterogeneity in tumor radiosensitivity for nonsmall cell lung cancer using tumor-volume variation data

    SciTech Connect

    Chvetsov, Alexei V. Schwartz, Jeffrey L.; Mayr, Nina; Yartsev, Slav

    2014-06-15

    Purpose: In our previous work, the authors showed that a distribution of cell surviving fractionsS{sub 2} in a heterogeneous group of patients could be derived from tumor-volume variation curves during radiotherapy for head and neck cancer. In this research study, the authors show that this algorithm can be applied to other tumors, specifically in nonsmall cell lung cancer. This new application includes larger patient volumes and includes comparison of data sets obtained at independent institutions. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage computed tomography. Statistical distributions of cell surviving fractionsS{sub 2} and clearance half-lives of lethally damaged cells T{sub 1/2} have been reconstructed in each patient group by using a version of the two-level cell population model of tumor response and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Nonsmall cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractionsS{sub 2} for nonsmall cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sub 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Conclusions: The data obtained

  16. Lymphopenia Association With Gross Tumor Volume and Lung V5 and Its Effects on Non-Small Cell Lung Cancer Patient Outcomes

    SciTech Connect

    Tang, Chad; Liao, Zhongxing; Gomez, Daniel; Levy, Lawrence; Zhuang, Yan; Gebremichael, Rediet A.; Hong, David S.; Komaki, Ritsuko; Welsh, James W.

    2014-08-01

    Purpose: Radiation therapy (RT) can both suppress and stimulate the immune system. We sought to investigate the mechanisms underlying radiation-induced lymphopenia and its associations with patient outcomes in non-small cell lung cancer (NSCLC). Methods and Materials: Subjects consisted of 711 patients who had received definitive RT for NSCLC. A lymphocyte nadir was calculated as the minimum lymphocyte value measured during definitive RT. Associations between gross tumor volumes (GTVs) and lung dose-volume histogram (DVH) parameters with lymphocyte nadirs were assessed with Spearman correlation coefficients. Relationships between lymphocyte nadirs with overall survival (OS) and event free survival (EFS) were evaluated with Kaplan-Meier analysis and compared with log-rank test results. Multivariate regressions were conducted with linear and Cox regression analyses. All variables were analyzed as continuous if possible. Results: Larger GTVs were correlated with lower lymphocyte nadirs regardless of concurrent chemotherapy receipt (with concurrent: r = −0.26, P<.0001; without: r = −0.48, P<.0001). Analyses of lung DVH parameters revealed significant correlations at lower doses (lung V5-V10: P<.0001) that incrementally decreased and became nonsignificant at higher doses (lung V60-V70: P>.05). Of note, no significant associations were detected between GTV and lung DVH parameters with total leukocyte, neutrophil, or monocyte nadirs during RT or with lymphocyte count prior to RT. Multivariate analysis revealed larger GTV (P<.0001), receipt of concurrent chemotherapy (P<.0001), twice-daily radiation fractionation (P=.02), and stage III disease (P=.05) to be associated with lower lymphocyte nadirs. On univariate analysis, patients with higher lymphocyte nadirs exhibited significantly improved OS (hazard ratio [HR] = 0.51 per 10{sup 3} lymphocytes/μL, P=.01) and EFS (HR = 0.46 per 10{sup 3} lymphocytes/μL, P<.0001). These differences held on multivariate analyses

  17. Can the single-breath helium dilution method predict lung volumes as measured by whole-body plethysmography?*

    PubMed Central

    Coertjens, Patrícia Chaves; Knorst, Marli Maria; Dumke, Anelise; Pasqualoto, Adriane Schmidt; Riboldi, João; Barreto, Sérgio Saldanha Menna

    2013-01-01

    OBJECTIVE: To compare TLC and RV values obtained by the single-breath helium dilution (SBHD) method with those obtained by whole-body plethysmography (WBP) in patients with normal lung function, patients with obstructive lung disease (OLD), and patients with restrictive lung disease (RLD), varying in severity, and to devise equations to estimate the SBHD results. METHODS: This was a retrospective cross-sectional study involving 169 individuals, of whom 93 and 49 presented with OLD and RLD, respectively, the remaining 27 having normal lung function. All patients underwent spirometry and lung volume measurement by both methods. RESULTS: TLC and RV were higher by WBP than by SBHD. The discrepancy between the methods was more pronounced in the OLD group, correlating with the severity of airflow obstruction. In the OLD group, the correlation coefficient of the comparison between the two methods was 0.57 and 0.56 for TLC and RV, respectively (p < 0.001 for both). We used regression equations, adjusted for the groups studied, in order to predict the WBP values of TLC and RV, using the corresponding SBHD values. It was possible to create regression equations to predict differences in TLC and RV between the two methods only for the OLD group. The TLC and RV equations were, respectively, ∆TLCWBP-SBHD in L = 5.264 − 0.060 × FEV1/FVC (r2 = 0.33; adjusted r2 = 0.32) and ∆RVWBP-SBHD in L = 4.862 − 0.055 × FEV1/FVC (r2 = 0.31; adjusted r2 = 0.30). CONCLUSIONS: The correction of TLC and RV results obtained by SBHD can improve the accuracy of this method for assessing lung volumes in patients with OLD. However, additional studies are needed in order to validate these equations. PMID:24473761

  18. Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images

    SciTech Connect

    Wang, Lu; Chen, Xiaoming; Lin, Mu-Han; Lin, Teh; Fan, Jiajin; Jin, Lihui; Ma, Charlie M.; Xue, Jun

    2013-11-15

    centroid position of the cylinder, sphere, and cone was less than 1.4 mm between the two modalities for all motion periods studied. For the ITV volume evaluation, the authors found that both MIP-based and CBCT-based ITVs increased with increases of motion period. Furthermore, the MIP-based ITV volumes were generally larger than those determined from the CBCT images, with the difference in autocontoured volumes being 2.57%, 1.66%, and 1.82% for the sphere, cylinder, and cone, respectively, while these differences increased to 9.57%, 3.52%, 8.71% for the above objects when the gradient method was used. The authors found that the autocontour method was accurate enough to predict the actual ITV values with the absolute differences less than 2.4% comparing to the theoretically predicted values.Conclusions: The extreme location and the centroid position of the objects agree with each other between the two image modalities when the breathing motion is sinusoidal. Although the ITV volumes delineated from both image modalities changed with the motion period, the differences in ITV between the two modalities were minimal when an optimized window level was used. The authors’ results suggest that CBCT and MIP images are equivalent in determining an ITV's position in the conditions studied. The CBCT is adequate in providing imaging-guidance for lung cancer treatment.

  19. Dose-Volume Comparison of Proton Radiotherapy and Stereotactic Body Radiotherapy for Non-Small-Cell Lung Cancer

    SciTech Connect

    Kadoya, Noriyuki; Obata, Yasunori; Kato, Takahiro; Kagiya, Masaru; Nakamura, Tatsuya; Tomoda, Takuya; Takada, Akinori; Takayama, Kanako; Fuwa, Nobukazu

    2011-03-15

    Purpose: This study designed photon and proton treatment plans for patients treated with hypofractionated proton radiotherapy (PT) at the Southern Tohoku Proton Therapy Center (STPTC). We then calculated dosimetric parameters and compared results with simulated treatment plans for stereotactic body radiotherapy (SBRT), using dose--volume histograms to clearly explain differences in dose distributions between PT and SBRT. Methods and Materials: Twenty-one patients with stage I non-small-cell lung cancer (stage IA, n = 15 patients; stage IB, n = 6 patients) were studied. All tumors were located in the peripheral lung, and total dose was 66 Gray equivalents (GyE) (6.6 GyE/fraction). For treatment planning, beam incidence for proton beam technique was restricted to two to three directions for PT, and seven or eight noncoplanar beams were manually selected for SBRT to achieve optimal planning target volume (PTV) coverage and minimal dose to organs at risk. Results: Regarding lung tissues, mean dose, V5, V10, V13, V15, and V20 values were 4.6 Gy, 13.2%, 11.4%, 10.6%, 10.1%, and 9.1%, respectively, for PT, whereas those values were 7.8 Gy, 32.0%, 21.8%, 17.4%, 15.3%, and 11.4%, respectively, for SBRT with a prescribed dose of 66 Gy. Pearson product moment correlation coefficients between PTV and dose--volume parameters of V5, V10, V15, and V20 were 0.45, 0.52, 0.58, and 0.63, respectively, for PT, compared to 0.52, 0.45, 0.71, and 0.74, respectively, for SBRT. Conclusions: Correlations between dose--volume parameters of the lung and PTV were observed and may indicate that PT is more advantageous than SBRT when treating a tumor with a relatively large PTV or several tumors.

  20. [Margin determination from clinical to planning target volume for lung cancer treated with conformal or intensity-modulated irradiation].

    PubMed

    Berthelot, K; Thureau, S; Giraud, P

    2016-10-01

    Technological progress in radiotherapy enables more precision for treatment planning and delivery. The margin determination between the clinical target volume and the planning target volumes stem from the estimation of geometric uncertainties of the tumour localization into the radiation beam. The inner motion complexity of lung tumours has led to the use of 4D computed tomography and nurtures specific dosimetric concerns. Few strategies consisting in integrating tumour motion allow margin reduction regarding inner movements. The patient immobilization and onboard imagery improvement decrease the setup uncertainties. Each step between the initial planning imagery and treatment delivery has to be analysed as systematic or random errors to calculate the optimal planning margin.

  1. Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-structure dose-volume metrics

    SciTech Connect

    Rosenberg, Mara W.; Kato, Catherine M.; Carson, Kelly M.P.; Matsunaga, Nathan M.; Arao, Robert F.; Doss, Emily J.; McCracken, Charles L.; Meng, Lu Z.; Chen, Yiyi; Laub, Wolfram U.; Fuss, Martin; Tanyi, James A.

    2013-01-01

    To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non–small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: IMRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose ∼ 150% PD) for a 6-MV photon beam. Plan conformality, R{sub 50} (ratio of volume circumscribed by the 50% isodose line and the PTV), and D{sub 2} {sub cm} (D{sub max} at a distance ≥2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD]) and percent V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} Gy were assessed. Spinal cord and esophagus D{sub max} and D{sub 5}/D{sub 50} were computed. Chest wall (CW) D{sub max} and absolute V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} {sub Gy} were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and V{sub 10}/V{sub 5} {sub Gy}, as well as contralateral CW D{sub max} and V{sub 10}/V{sub 5} {sub Gy} (all p < 0.001). Nominal reductions of D{sub max} and D{sub 5}/D{sub 50} for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, R{sub 50} significantly improved with IMRT

  2. 3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours

    NASA Astrophysics Data System (ADS)

    Hornblower, V. D. M.; Yu, E.; Fenster, A.; Battista, J. J.; Malthaner, R. A.

    2007-01-01

    The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial 'tumours' were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the 'tumours' were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the ultrasound images and a manual-radial segmentation technique and these were compared with the known volumes of the agar. In vitro measurements had average accuracy and precision of 4.76% and 1.77%, respectively; in vivo measurements had average accuracy and precision of 8.18% and 1.75%, respectively. The 3D thoracoscopic ultrasound can be used to accurately and reproducibly measure 'tumour' volumes both in vivo and ex vivo.

  3. SU-E-J-75: Importance of 4DCT for Target Volume Definition in Stereotactic Lung Radiotherapy

    SciTech Connect

    Goksel, E; Cone, D; Kucucuk, H; Senkesen, O; Yilmaz, M; Aslay, I; Tezcanli, E; Garipagaoglu, M; Sengoz, M

    2014-06-01

    Purpose: We aimed to investigate the importance of 4DCT for lung tumors treated with SBRT and whether maximum intensity projection (MIP) and free breathing (FB) images can compansate for tumor movement. Methods: Six patients with primary lung cancer and 2 patients with lung metastasis with a median age of 69.5 (42–86) were included. Patients were positioned supine on a vacuum bag. In addition to FB planning CT images, 4DCT images were obtained at 3 mm intervals using Varian RPM system with (Siemens Somatom Sensetion 64). MIP series were reconstructed using 4DCT images. PTV-FB and PTV-MIP (GTV+5mm) volumes were contoured using FB and MIP series, respectively. GTVs were defined on each of eight different breathing phase images and were merged to create the ITV. PTV-4D was generated with a 5 mm margin to ITV. PTV-MIP and PTV-4D contours were copied to FB CT series and treatment plans for PTV-MIP and PTV-FB were generated using RapidArc (2 partial arc) technique in Eclipse (version 11, AAA algorithm). The prescription dose was 5600cGy in 7 fractions. ITV volumes receiving prescription dose (%) and V95 for ITV were calculated for each treatment plan. Results: The mean PTV-4B, PTV-MIP and PTV-FB volumes were 23.2 cc, 15.4cc ve 11cc respectively. Median volume of ITV receiving the prescription dose was 34.6% (16.4–70 %) and median V95 dose for ITV was 1699cGy (232cGy-5117cGy) in the plan optimized for PTV-FB as the reference. When the plan was optimized for PTV-MIP, median ITV volume receiving the prescription dose was 67.15% (26–86%) and median V95 dose for ITV was 4231cGy (1735cGy-5290cGy). Conclusion: Images used in lung SBRT are critical for treatment quality; FB and MIP images did not compensate target movement, therefore 4DCT images should be obtained for all patients undergoing lung SBRT or the safety margins should be adjusted.

  4. Staged bilateral single-port thoracoscopic lung volume reduction surgery: A report of 11 cases

    PubMed Central

    Zhang, Miao; Wang, Heng; Pan, Xue-Feng; Wu, Wen-Bin; Zhang, Hui

    2016-01-01

    The aim of the present study was to investigate the feasibility and efficacy of staged bilateral single-port thoracoscopic lung volume reduction surgery (LVRS) for patients with chronic obstructive pulmonary emphysema (COPE). Eleven male patients with a mean age of 60.27±12.11 years with bilateral COPE and bullae were admitted to the Department of Thoracic Surgery, Xuzhou Central Hospital from January 2013 to June 2014. The patients underwent staged bilateral single-port thoracoscopic LVRS. The hyperinflated bullae were resected using endoscopic staplers (Endo-GIA), followed by continuous suture and biological glue for reinforcement of the margin. In addition, pulmonary function, blood gas assay, 6-min walk distance (6MWD) and life quality evaluated by a short form 36-item health survey questionnaire (SF-36) were recorded before and after LVRS, respectively. All the patients survived after surgery. The chest tube drainage time was 9.09±1.31 days and postoperative hospital stay was 15.73±2.75 days, with 5 cases of persistent air leakage and 7 cases of pulmonary infection which were finally cured. The patients were followed up for 3 to 12 months, and the pulmonary function, partial pressure of oxygen (pO2), 6MWD and life quality after unilateral or bilateral LVRS were improved compared to these parameters before surgery. However, there was no significant difference between unilateral and bilateral LVRS in terms of life quality. In conclusion, staged bilateral single-port thoracoscopic LVRS may improve the short-term life quality of patients with COPE. PMID:27882084

  5. Effects of Lung Volume Reduction Surgery on Gas Exchange and Breathing Pattern During Maximum Exercise

    PubMed Central

    Criner, Gerard J.; Belt, Patricia; Sternberg, Alice L.; Mosenifar, Zab; Make, Barry J.; Utz, James P.; Sciurba, Frank

    2009-01-01

    Background: The National Emphysema Treatment Trial studied lung volume reduction surgery (LVRS) for its effects on gas exchange, breathing pattern, and dyspnea during exercise in severe emphysema. Methods: Exercise testing was performed at baseline, and 6, 12, and 24 months. Minute ventilation (V̇e), tidal volume (Vt), carbon dioxide output (V̇co2), dyspnea rating, and workload were recorded at rest, 3 min of unloaded pedaling, and maximum exercise. Pao2, Paco2, pH, fraction of expired carbon dioxide, and bicarbonate were also collected in some subjects at these time points and each minute of testing. There were 1,218 patients enrolled in the study (mean [± SD] age, 66.6 ± 6.1 years; mean, 61%; mean FEV1, 0.77 ± 0.24 L), with 238 patients participating in this substudy (mean age, 66.1 ± 6.8 years; mean, 67%; mean FEV1, 0.78 ± 0.25 L). Results: At 6 months, LVRS patients had higher maximum V̇e (32.8 vs 29.6 L/min, respectively; p = 0.001), V̇co2, (0.923 vs 0.820 L/min, respectively; p = 0.0003), Vt (1.18 vs 1.07 L, respectively; p = 0.001), heart rate (124 vs 121 beats/min, respectively; p = 0.02), and workload (49.3 vs 45.1 W, respectively; p = 0.04), but less breathlessness (as measured by Borg dyspnea scale score) [4.4 vs 5.2, respectively; p = 0.0001] and exercise ventilatory limitation (49.5% vs 71.9%, respectively; p = 0.001) than medical patients. LVRS patients with upper-lobe emphysema showed a downward shift in Paco2 vs V̇co2 (p = 0.001). During exercise, LVRS patients breathed slower and deeper at 6 months (p = 0.01) and 12 months (p = 0.006), with reduced dead space at 6 months (p = 0.007) and 24 months (p = 0.006). Twelve months after patients underwent LVRS, dyspnea was less in patients with upper-lobe emphysema (p = 0.001) and non–upper-lobe emphysema (p = 0.007). Conclusion: During exercise following LVRS, patients with severe emphysema improve carbon dioxide elimination and dead space, breathe slower and deeper, and report less dyspnea

  6. Impact of PET - CT motion correction in minimizing the gross tumor volume in non-small cell lung cancer

    PubMed Central

    Masoomi, Michael A; McLean, Anne H; Bouchareb, Yassine; Ryder, Will; Robinson, Andy

    2013-01-01

    Objective(s): To investigate the impact of respiratory motion on localization, and quantification of lung lesions for the Gross Tumor Volume utilizing a fully automated Auto3Dreg program and dynamic NURBS-based cardiac-torso digitized phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumor lesions. The motion correction technique adopted in this study was an image-based motion correction approach using, a voxel-intensity-based and a multi-resolution multi-optimization (MRMO) algorithm. The NCAT phantom was used to generate CT attenuation maps and activity distribution volumes for the lung regions. All the generated frames were co-registered to a reference frame using a time efficient scheme. Quantitative assessment including Region of Interest (ROI), image fidelity and image correlation techniques, as well as semi-quantitative line profile analysis and qualitatively overlaying non-motion and motion corrected image frames were performed. Results: The largest motion was observed in the Z-direction. The greatest translation was for the frame 3, end inspiration, and the smallest for the frame 5 which was closet frame to the reference frame at 67% expiration. Visual assessment of the lesion sizes, 20-60mm at 3 different locations, apex, mid and base of lung showed noticeable improvement for all the foci and their locations. The maximum improvements for the image fidelity were from 0.395 to 0.930 within the lesion volume of interest. The greatest improvement in activity concentration underestimation was 7.7% below the true activity for the 20 mm lesion in comparison to 34.4% below, prior to correction. The discrepancies in activity underestimation were reduced with increasing the lesion sizes. Overlaying activity distribution on the attenuation map showed improved localization of the PET metabolic information to the anatomical CT images. Conclusion: The respiratory motion correction for the

  7. Mathematical modelling of tumour volume dynamics in response to stereotactic ablative radiotherapy for non-small cell lung cancer

    NASA Astrophysics Data System (ADS)

    Tariq, Imran; Humbert-Vidan, Laia; Chen, Tao; South, Christopher P.; Ezhil, Veni; Kirkby, Norman F.; Jena, Rajesh; Nisbet, Andrew

    2015-05-01

    This paper reports a modelling study of tumour volume dynamics in response to stereotactic ablative radiotherapy (SABR). The main objective was to develop a model that is adequate to describe tumour volume change measured during SABR, and at the same time is not excessively complex as lacking support from clinical data. To this end, various modelling options were explored, and a rigorous statistical method, the Akaike information criterion, was used to help determine a trade-off between model accuracy and complexity. The models were calibrated to the data from 11 non-small cell lung cancer patients treated with SABR. The results showed that it is feasible to model the tumour volume dynamics during SABR, opening up the potential for using such models in a clinical environment in the future.

  8. Clinical Roles of Lung Volumes Detected by Body Plethysmography and Helium Dilution in Asthmatic Patients: A Correlation and Diagnosis Analysis

    PubMed Central

    Luo, Jian; Liu, Dan; Chen, Guo; Liang, Binmiao; Liu, Chuntao

    2017-01-01

    Roles of lung volumes in asthma remain controversial. We aimed to evaluate the efficacy of lung volumes in differentiating asthma severity levels. Consecutive outpatients with chronic persistent asthma were enrolled, and body plethysmography (BP) and helium dilution (HD) were performed simultaneously to extract RV%pred, TLC%pred, and RV/TLC. Significant negative correlations were found between FEV1%pred and RV%pred (r = −0.557, P < 0.001), TLC%pred (r = −0.387, P < 0.001), and RV/TLC (r = −0.485, P < 0.001) measured by BP, as well as difference in volumes between these two techniques (ΔRV%pred, ΔTLC%pred and ΔRV/TLC). In mild and moderate asthma, AUC of RV%pred detected by BP and ΔTLC%pred was 0.723 (95%CI 0.571–0.874, P = 0.005) and 0.739 (95%CI 0.607–0.872, P = 0.002) with sensitivity and specificity being 79.41% and 88.24%, and 65.22% and 56.52% at cut-off of 145.40% and 14.23%, respectively. In moderate and severe asthma, AUC of RV%pred detected by BP and ΔTLC%pred was 0.782 (95%CI 0.671–0.893, P < 0.001) and 0.788 (95%CI 0.681–0.894, P < 0.002) with sensitivity and specificity being 77.78% and 97.22%, and 73.53% and 52.94% at cut-off of 179.85% and 20.22%, respectively. In conclusion, lung volumes are reliable complement of FEV1 in identifying asthma severity levels. PMID:28098214

  9. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging

    NASA Astrophysics Data System (ADS)

    Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V.; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L.; Beauchemin, Steven S.; Rodrigues, George; Gaede, Stewart

    2015-02-01

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.

  10. SU-E-J-79: Internal Tumor Volume Motion and Volume Size Assessment Using 4D CT Lung Data

    SciTech Connect

    Jurkovic, I; Stathakis, S; Li, Y; Patel, A; Vincent, J; Papanikolaou, N; Mavroidis, P

    2014-06-01

    Purpose: To assess internal tumor volume change through breathing cycle and associated tumor motion using the 4DCT data. Methods: Respiration induced volume change through breathing cycle and associated motion was analyzed for nine patients that were scanned during the different respiratory phases. The examined datasets were the maximum and average intensity projections (MIP and AIP) and the 10 phases of the respiratory cycle. The internal target volume (ITV) was delineated on each of the phases and the planning target volume (PTV) was then created by adding setup margins to the ITV. Tumor motion through the phases was assessed using the acquired 4DCT dataset, which was then used to determine if the margins used for the ITV creation successfully encompassed the tumor in three dimensions. Results: Results showed that GTV motion along the superior inferior axes was the largest in all the cases independent of the tumor location and/or size or the use of abdomen compression. The extent of the tumor motion was found to be connected with the size of the GTV. The smallest GTVs exhibited largest motion vector independent of the tumor location. The motion vector size varied through the phases depending on the tumor size and location and it was smallest for phases 20 and 30. The smaller the volume of the delineated GTV, the greater its volume difference through the different respiratory phases was. The average GTV volume change was largest for the phases 60 and 70. Conclusion: Even if GTV is delineated using both AIP and MIP datasets, its motion extent will exceed the used margins especially for the very small GTV volumes. When the GTV size is less than 10 cc it is recommended to use fusion of the GTVs through all the phases to create the planning ITV.

  11. [Role of functional imaging in the definition of target volumes for lung cancer radiotherapy].

    PubMed

    Thureau, S; Hapdey, S; Vera, P

    2016-10-01

    Functional imaging with positron emission tomography (PET) is interesting to optimize lung radiotherapy planning, and probably to deliver a heterogeneous dose or adapt the radiation dose during treatment. Only fluorodeoxyglucose (FDG) PET-computed tomography (CT) is validated for staging lung cancer and planning radiotherapy. The optimal segmentation methods remain to be defined as well as the interest of "dose painting" from pre-treatment PET (metabolism: FDG) or hypoxia (fluoromisonidazole: FMISO) and the interest of replanning based on pertherapeutic PET.

  12. The effect of image-guided radiation therapy on the margin between the clinical target volume and planning target volume in lung cancer

    SciTech Connect

    Liang, Jun; Li, Minghui; Zhang, Tao; Han, Wei; Chen, Dongfu; Hui, Zhouguang; Lv, Jima; Zhang, Zhong; Zhang, Yin; Zhang, Liansheng; Zheng, Rong; Dai, Jianrong; Wang, Luhua

    2014-02-15

    Introduction: This study aimed to evaluate the effect of image-guided radiation therapy (IGRT) on the margin between the clinical target volume (CTV) and planning target volume (PTV) in lung cancer. Methods: The CTV and PTV margin were determined in three dimensions by four radiation oncologists using a standard method in 10 lung cancer patients, and compared to consensus values. Transfer error was measured using a rigid phantom containing gold markers. Systematic error and random error set up errors were calculated in three dimensions from pre-treatment and post-treatment cone beam CT scans. Finally, the margin between the CTV and PTV was corrected for set up error and calculated. Results: The margins between the CTV and PTV with IGRT (and without IGRT) were 0.88 cm (0.96 cm), 0.99 cm (1.08 cm) and 1.28 cm (1.82 cm) in the anterior and posterior (AP), left and right (LR) and superior and inferior (SI) directions, respectively. Images from two other patients verified the validity of the corrected margin. The target delineation errors of the radiation oncologists are considered to be the largest compared with the set up errors. The application of IGRT reduced the set up errors and the margins between CTV and PTV. Conclusions: The delineation errors of radiation oncologists are the most important factor to consider for the margin between CTV and PTV for lung cancer. IGRT can reduce the margins by reducing the set up errors, especially in the SI direction. Further research is required to assess whether the reduction in the margin is solely based on set up errors.

  13. Effects of reduced tidal volume ventilation on pulmonary function in mice before and after acute lung injury.

    PubMed

    Thammanomai, Apiradee; Majumdar, Arnab; Bartolák-Suki, Erzsébet; Suki, Béla

    2007-11-01

    We investigated the influence of load impedance on ventilator performance and the resulting effects of reduced tidal volume (Vt) on lung physiology during a 30-min ventilation of normal mice and 10 min of additional ventilation following lavage-induced injury at two positive end-expiratory pressure (PEEP) levels. Respiratory mechanics were regularly monitored, and the lavage fluid was tested for the soluble E-cadherin, an epithelial cell adhesion molecule, and surfactant protein (SP) B. The results showed that, due to the load dependence of the delivered Vt from the small-animal ventilator: 1) uncontrolled ventilation in normal mice resulted in a lower delivered Vt (6 ml/kg at 3-cmH(2)O PEEP and 7 ml/kg at 6-cmH(2)O PEEP) than the prescribed Vt (8 ml/kg); 2) at 3-cmH(2)O PEEP, uncontrolled ventilation in normal mice led to an increase in lung parenchymal functional heterogeneity, a reduction of SP-B, and an increase in E-cadherin; 3) at 6-cmH(2)O PEEP, ventilation mode had less influence on these parameters; and 4) in a lavage model of acute respiratory distress syndrome, delivered Vt decreased to 4 ml/kg from the prescribed 8 ml/kg, which resulted in severely compromised lung function characterized by increases in lung elastance, airway resistance, and alveolar tissue heterogeneity. Furthermore, the low Vt ventilation also resulted in poor survival rate independent of PEEP. These results highlight the importance of delivering appropriate Vt to both the normal and injured lungs. By leaving the Vt uncompensated, it can significantly alter physiological and biological responses in mice.

  14. Lung membrane conductance and capillary volume derived from the NO and CO transfer in high-altitude newcomers.

    PubMed

    Martinot, Jean-Benoît; Mulè, Massimiliano; de Bisschop, Claire; Overbeek, Maria J; Le-Dong, Nhat-Nam; Naeije, Robert; Guénard, Hervé

    2013-07-15

    Acute exposure to high altitude may induce changes in carbon monoxide (CO) membrane conductance (DmCO) and capillary lung volume (Vc). Measurements were performed in 25 lowlanders at Brussels (D0), at 4,300 m after a 2- or 3-day exposure (D2,3) without preceding climbing, and 5 days later (D7,8), before and after an exercise test, under a trial with two arterial pulmonary vasodilators or a placebo. The nitric oxide (NO)/CO transfer method was used, assuming both infinite and finite values to the NO blood conductance (θNO). Doppler echocardiography provided hemodynamic data. Compared with sea level, lung diffusing capacity for CO increased by 24% at D2,3 and is returned to control at D7,8. The acute increase in lung diffusing capacity for CO resulted from increases in DmCO and Vc with finite and infinite θNO assumptions. The alveolar volume increased by 16% at D2,3 and normalized at D7,8. The mean increase in systolic arterial pulmonary pressure at rest at D2,3 was minimal. In conclusion, the acute increase in Vc may be related to the increase in alveolar volume and to the increase in capillary pressure. Compared with the infinite θNO value, the use of a finite θNO value led to about a twofold increase in DmCO value and to a persistent increase in DmCO at D7,8 compared with D0. After exercise, DmCO decreased slightly less in subjects treated by the vasodilators, suggesting a beneficial effect on interstitial edema.

  15. The effect of increased lung volume in chronic obstructive pulmonary disease on upper airway obstruction during sleep

    PubMed Central

    Biselli, Paolo; Grossman, Peter R.; Kirkness, Jason P.; Patil, Susheel P.; Smith, Philip L.; Schwartz, Alan R.

    2015-01-01

    Patients with chronic obstructive pulmonary disease (COPD) exhibit increases in lung volume due to expiratory airflow limitation. Increases in lung volumes may affect upper airway patency and compensatory responses to inspiratory flow limitation (IFL) during sleep. We hypothesized that COPD patients have less collapsible airways inversely proportional to their lung volumes, and that the presence of expiratory airflow limitation limits duty cycle responses to defend ventilation in the presence of IFL. We enrolled 18 COPD patients and 18 controls, matched by age, body mass index, sex, and obstructive sleep apnea disease severity. Sleep studies, including quantitative assessment of airflow at various nasal pressure levels, were conducted to determine upper airway mechanical properties [passive critical closing pressure (Pcrit)] and for quantifying respiratory timing responses to experimentally induced IFL. COPD patients had lower passive Pcrit than their matched controls (COPD: −2.8 ± 0.9 cmH2O; controls: −0.5 ± 0.5 cmH2O, P = 0.03), and there was an inverse relationship of subject's functional residual capacity and passive Pcrit (−1.7 cmH2O/l increase in functional residual capacity, r2 = 0.27, P = 0.002). In response to IFL, inspiratory duty cycle increased more (P = 0.03) in COPD patients (0.40 to 0.54) than in controls (0.41 to 0.51) and led to a marked reduction in expiratory time from 2.5 to 1.5 s (P < 0.01). COPD patients have a less collapsible airway and a greater, not reduced, compensatory timing response during upper airway obstruction. While these timing responses may reduce hypoventilation, it may also increase the risk for developing dynamic hyperinflation due to a marked reduction in expiratory time. PMID:26048975

  16. Inflation and deflation pressure-volume loops in anesthetized pinnipeds confirms compliant chest and lungs.

    PubMed

    Fahlman, Andreas; Loring, Stephen H; Johnson, Shawn P; Haulena, Martin; Trites, Andrew W; Fravel, Vanessa A; Van Bonn, William G

    2014-01-01

    We examined structural properties of the marine mammal respiratory system, and tested Scholander's hypothesis that the chest is highly compliant by measuring the mechanical properties of the respiratory system in five species of pinniped under anesthesia (Pacific harbor seal, Phoca vitulina; northern elephant seal, Mirounga angustirostris; northern fur seal Callorhinus ursinus; California sea lion, Zalophus californianus; and Steller sea lion, Eumetopias jubatus). We found that the chest wall compliance (CCW) of all five species was greater than lung compliance (airways and alveoli, CL) as predicted by Scholander, which suggests that the chest provides little protection against alveolar collapse or lung squeeze. We also found that specific respiratory compliance was significantly greater in wild animals than in animals raised in an aquatic facility. While differences in ages between the two groups may affect this incidental finding, it is also possible that lung conditioning in free-living animals may increase pulmonary compliance and reduce the risk of lung squeeze during diving. Overall, our data indicate that compliance of excised pinniped lungs provide a good estimate of total respiratory compliance.

  17. Teaching Absolute Value Meaningfully

    ERIC Educational Resources Information Center

    Wade, Angela

    2012-01-01

    What is the meaning of absolute value? And why do teachers teach students how to solve absolute value equations? Absolute value is a concept introduced in first-year algebra and then reinforced in later courses. Various authors have suggested instructional methods for teaching absolute value to high school students (Wei 2005; Stallings-Roberts…

  18. The Prognostic Value of Residual Volume/Total Lung Capacity in Patients with Chronic Obstructive Pulmonary Disease.

    PubMed

    Shin, Tae Rim; Oh, Yeon-Mok; Park, Joo Hun; Lee, Keu Sung; Oh, Sunghee; Kang, Dae Ryoung; Sheen, Seungsoo; Seo, Joon Beom; Yoo, Kwang Ha; Lee, Ji-Hyun; Kim, Tae-Hyung; Lim, Seong Yong; Yoon, Ho Il; Rhee, Chin Kook; Choe, Kang-Hyeon; Lee, Jae Seung; Lee, Sang-Do

    2015-10-01

    The prognostic role of resting pulmonary hyperinflation as measured by residual volume (RV)/total lung capacity (TLC) in chronic obstructive pulmonary disease (COPD) remains poorly understood. Therefore, this study aimed to identify the factors related to resting pulmonary hyperinflation in COPD and to determine whether resting pulmonary hyperinflation is a prognostic factor in COPD. In total, 353 patients with COPD in the Korean Obstructive Lung Disease cohort recruited from 16 hospitals were enrolled. Resting pulmonary hyperinflation was defined as RV/TLC ≥ 40%. Multivariate logistic regression analysis demonstrated that older age (P = 0.001), lower forced expiratory volume in 1 second (FEV1) (P < 0.001), higher St. George Respiratory Questionnaire (SGRQ) score (P = 0.019), and higher emphysema index (P = 0.010) were associated independently with resting hyperinflation. Multivariate Cox regression model that included age, gender, dyspnea scale, SGRQ, RV/TLC, and 6-min walking distance revealed that an older age (HR = 1.07, P = 0.027), a higher RV/TLC (HR = 1.04, P = 0.025), and a shorter 6-min walking distance (HR = 0.99, P < 0.001) were independent predictors of all-cause mortality. Our data showed that older age, higher emphysema index, higher SGRQ score, and lower FEV1 were associated independently with resting pulmonary hyperinflation in COPD. RV/TLC is an independent risk factor for all-cause mortality in COPD.

  19. Detectable change of lung nodule volume with CT in a phantom study with high and low signal to background contrast

    NASA Astrophysics Data System (ADS)

    Gavrielides, Marios A.; Li, Qin; Zeng, Rongping; Gong, Qi; Myers, Kyle; Sahiner, Berkman; Petrick, Nicholas

    2016-03-01

    In previous work we developed a method for predicting the minimum detectable change (MDC) in nodule volume based on volumetric CT measurements. MDC was defined as the minimum increase/decrease in a nodule volume distinguishable from the baseline measurement at a specified level of detection performance, assessed using the area under the ROC curve (AUC). In this work we derived volume estimates of a set of synthetic nodules and calculated the detection performance for distinguishing them from baseline measurements. Eight spherical objects of 100HU radio density ranging in diameter from 5.0mm to 5.75mm and 8.0mm to 8.75mm with 0.25mm increments were placed in an anthropomorphic phantom with either no background (high-contrast task) or gelatin background (low-contrast task). The baseline was defined as 5.0mm for the first set of nodules and 8.0mm for the second set. The phantom was scanned using varying exposures, and reconstructed with slice thickness of 0.75, 1.5, and 3.0mm and two reconstruction kernels (standard and smooth). Volume measurements were derived using a previously developed matched- filter approach. Results showed that nodule size, slice thickness, and nodule-to-background contrast affected detectable change in nodule volume when using our volume estimator and the acquisition settings from our study. We also compared our experimental results to the values estimated by our previously-developed MDC prediction method. We found that experimental data for the 8mm baseline nodules matched very well with our predicted values of MDC. These results support considering the use of this metric when standardizing imaging protocols for lung nodule size change assessment.

  20. Effect of lung-protective ventilation with lower tidal volumes on clinical outcomes among patients undergoing surgery: a meta-analysis of randomized controlled trials

    PubMed Central

    Gu, Wan-Jie; Wang, Fei; Liu, Jing-Chen

    2015-01-01

    Background: In anesthetized patients undergoing surgery, the role of lung-protective ventilation with lower tidal volumes is unclear. We performed a meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of this ventilation strategy on postoperative outcomes. Methods: We searched electronic databases from inception through September 2014. We included RCTs that compared protective ventilation with lower tidal volumes and conventional ventilation with higher tidal volumes in anesthetized adults undergoing surgery. We pooled outcomes using a random-effects model. The primary outcome measures were lung injury and pulmonary infection. Results: We included 19 trials (n = 1348). Compared with patients in the control group, those who received lung-protective ventilation had a decreased risk of lung injury (risk ratio [RR] 0.36, 95% confidence interval [CI] 0.17 to 0.78; I2 = 0%) and pulmonary infection (RR 0.46, 95% CI 0.26 to 0.83; I2 = 8%), and higher levels of arterial partial pressure of carbon dioxide (standardized mean difference 0.47, 95% CI 0.18 to 0.75; I2 = 65%). No significant differences were observed between the patient groups in atelectasis, mortality, length of hospital stay, length of stay in the intensive care unit or the ratio of arterial partial pressure of oxygen to fraction of inspired oxygen. Interpretation: Anesthetized patients who received ventilation with lower tidal volumes during surgery had a lower risk of lung injury and pulmonary infection than those given conventional ventilation with higher tidal volumes. Implementation of a lung-protective ventilation strategy with lower tidal volumes may lower the incidence of these outcomes. PMID:25512653

  1. Quantification and Minimization of Uncertainties of Internal Target Volume for Stereotactic Body Radiation Therapy of Lung Cancer

    SciTech Connect

    Ge Hong; Cai Jing; Kelsey, Chris R.; Yin Fangfang

    2013-02-01

    Purpose: To quantify uncertainties in delineating an internal target volume (ITV) and to understand how these uncertainties may be individually minimized for stereotactic body radiation therapy (SBRT) of early stage non-small cell lung cancer (NSCLC). Methods and Materials: Twenty patients with NSCLC who were undergoing SBRT were imaged with free-breathing 3-dimensional computed tomography (3DCT) and 10-phase 4-dimensional CT (4DCT) for delineating gross tumor volume (GTV){sub 3D} and ITV{sub 10Phase} (ITV3). The maximum intensity projection (MIP) CT was also calculated from 10-phase 4DCT for contouring ITV{sub MIP} (ITV1). Then, ITV{sub COMB} (ITV2), ITV{sub 10Phase+GTV3D} (ITV4), and ITV{sub 10Phase+ITVCOMB} (ITV5) were generated by combining ITV{sub MIP} and GTV{sub 3D}, ITV{sub 10phase} and GTV{sub 3D}, and ITV{sub 10phase} and ITV{sub COMB}, respectively. All 6 volumes (GTV{sub 3D} and ITV1 to ITV5) were delineated in the same lung window by the same radiation oncologist. The percentage of volume difference (PVD) between any 2 different volumes was determined and was correlated to effective tumor diameter (ETD), tumor motion ranges, R{sub 3D}, and the amplitude variability of the recorded breathing signal (v) to assess their volume variations. Results: The mean (range) tumor motion (R{sub SI}, R{sub AP}, R{sub ML}, and R{sub 3D}) and breathing variability (v) were 7.6 mm (2-18 mm), 4.0 mm (2-8 mm), 3.3 mm (0-7.5 mm), 9.9 mm (4.1-18.7 mm), and 0.17 (0.07-0.37), respectively. The trend of volume variation was GTV{sub 3D} volumes were 11.1 {+-} 9.3 cc, 13.2 {+-} 10.5 cc, 14.9 {+-} 11.0 cc, 14.7 {+-} 11.4 cc, 15.9 {+-} 11.7 cc, and 16.4 {+-} 11.8 cc, respectively. All comparisons between the target volumes showed statistical significance (P{<=}.001), except for ITV2 and ITV3 (P=.594). The PVDs for all volume pairs correlated negatively with ETD (r{<=}-0.658, P{<=}.006) and positively with

  2. A Temporal Study of Gene Expression in Rat Lung Following Fixed-volume Hemorrhage

    DTIC Science & Technology

    2005-09-13

    2000. 2. Abraham E, Bursten S, Shenkar R, Allbee J, Tuder R, Woodson P, Guidot DM, Rice G, Singer JW, and Repine JE. Phosphatidic acid signaling...other immune cells. Other recent research has focused on free radicals, proteinases, and soluble agents in- cluding cytokines, arachidonic acid ...electrophoresis. A reference preparation consisting of equal amounts of RNA pooled from nine organs (liver, lung, kidney, spleen, heart, skeletal muscle

  3. Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

    SciTech Connect

    Kawase, Takatsugu; Kunieda, Etsuo Deloar, Hossain M.; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N.; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-10-01

    Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  4. Physics of negative absolute temperatures

    NASA Astrophysics Data System (ADS)

    Abraham, Eitan; Penrose, Oliver

    2017-01-01

    Negative absolute temperatures were introduced into experimental physics by Purcell and Pound, who successfully applied this concept to nuclear spins; nevertheless, the concept has proved controversial: a recent article aroused considerable interest by its claim, based on a classical entropy formula (the "volume entropy") due to Gibbs, that negative temperatures violated basic principles of statistical thermodynamics. Here we give a thermodynamic analysis that confirms the negative-temperature interpretation of the Purcell-Pound experiments. We also examine the principal arguments that have been advanced against the negative temperature concept; we find that these arguments are not logically compelling, and moreover that the underlying "volume" entropy formula leads to predictions inconsistent with existing experimental results on nuclear spins. We conclude that, despite the counterarguments, negative absolute temperatures make good theoretical sense and did occur in the experiments designed to produce them.

  5. Influence of Irradiated Lung Volumes on Perioperative Morbidity and Mortality in Patients After Neoadjuvant Radiochemotherapy for Esophageal Cancer

    SciTech Connect

    Daehn, Doreen; Martell, Joachim; Vorwerk, Hilke; Hess, Clemens F.; Becker, Heinz; Jung, Klaus; Hilgers, Reinhard; Wolff, Hendrik Andreas; Hermann, Robert Michael; Christiansen, Hans

    2010-05-01

    Purpose: In some randomized trials, the treatment outcome of locally advanced esophageal cancer has been significantly improved by neoadjuvant radiochemotherapy (RCT). However, increased perioperative pulmonary toxicity in terms of acute respiratory distress syndrome (ARDS) has been linked to radiation exposure of the lungs. In our study we evaluated perioperative morbidity and mortality in patients with cancer Stages IIA-IVA treated with curative intent either with surgery alone (S) or with neoadjuvant RCT followed by surgery (RCTS). Patients and Methods: Between 1996 and 2003, 55 patients received S, and 98 received RCTS. In the RCTS group, most patients received two cycles of 5-fluorouracil plus cisplatinum simultaneously with normofractionated radiotherapy (40Gy). Four weeks later they underwent surgery. Endpoints were the incidence of acute lung injury (ALI), ARDS, other postoperative complications, and mortality within 31 days. Results: Between both groups there were no significant differences between the incidence and severity of ALI and ARDS (RCTS: 42.9%, 42.9%; S: 45.5%, 38.2%). Furthermore, there were no significant differences in the incidences of pneumonia, pleural effusion, and pneumothorax (RCTS 29.6% vs. S 16.4%, p = 0.07). Perioperative complication rates and mortality did not vary significantly (mortality after RCTS 5.1% vs. S 3.6%). A detailed analysis of 54 RCTS patients according to lung dose-volume histograms did not show any correlation between ARDS and pulmonary exposure. In univariate analysis, only respiratory comorbidity correlated with ARDS. Conclusion: Neoadjuvant cisplatinum and 5-fluorouracil-based RCT apparently has no detrimental impact on the postoperative course.

  6. Lung Volume Reduction Surgery and Pulmonary Rehabilitation Improve Exercise Capacity and Reduce Dyspnea During Functional Activities in People with Emphysema

    PubMed Central

    2009-01-01

    Purpose: The purpose of this study was to examine the therapeutic effects of lung volume reduction surgery (LVRS) and pulmonary rehabilitation on levels of dyspnea during functional activities in patients with diffuse emphysema. Methods: Fifteen subjects who had undergone LVRS participated in this study. A visual analog scale (VAS) Activity Dyspnea Scales (VADS) measurement tool developed for this study was determined reliable in 10 subjects. The VADS was used to assess changes in dyspnea with functional activity in 10 subjects prior to and following the interventions of LVRS and pulmonary rehabilitation. Results: Results of this study indicate that LVRS followed by pulmonary rehabilitation significantly reduces levels of dyspnea during functional activities. Conclusion: The VADS developed for this study is a valid and reliable method of assessing changes in levels of dyspnea during functional activities in the LVRS population. PMID:20467532

  7. Mild hypothermia attenuates changes in respiratory system mechanics and modifies cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation.

    PubMed

    Dostál, P; Senkeřík, M; Pařízková, R; Bareš, D; Zivný, P; Zivná, H; Cerný, V

    2010-01-01

    Hypothermia was shown to attenuate ventilator-induced lung injury due to large tidal volumes. It is unclear if the protective effect of hypothermia is maintained under less injurious mechanical ventilation in animals without previous lung injury. Tracheostomized rats were randomly allocated to non-ventilated group (group C) or ventilated groups of normothermia (group N) and mild hypothermia (group H). After two hours of mechanical ventilation with inspiratory fraction of oxygen 1.0, respiratory rate 60 min(-1), tidal volume 10 ml x kg(-1), positive end-expiratory pressure (PEEP) 2 cm H2O or immediately after tracheostomy in non-ventilated animals inspiratory pressures were recorded, rats were sacrificed, pressure-volume (PV) curve of respiratory system constructed, bronchoalveolar lavage (BAL) fluid and aortic blood samples obtained. Group N animals exhibited a higher rise in peak inspiratory pressures in comparison to group H animals. Shift of the PV curve to right, higher total protein and interleukin-6 levels in BAL fluid were observed in normothermia animals in comparison with hypothermia animals and non-ventilated controls. Tumor necrosis factor-alpha was lower in the hypothermia group in comparison with normothermia and non-ventilated groups. Mild hypothermia attenuated changes in respiratory system mechanics and modified cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation in animals without previous lung injury.

  8. Absolutely classical spin states

    NASA Astrophysics Data System (ADS)

    Bohnet-Waldraff, F.; Giraud, O.; Braun, D.

    2017-01-01

    We introduce the concept of "absolutely classical" spin states, in analogy to absolutely separable states of bipartite quantum systems. Absolutely classical states are states that remain classical (i.e., a convex sum of projectors on coherent states of a spin j ) under any unitary transformation applied to them. We investigate the maximal size of the ball of absolutely classical states centered on the maximally mixed state and derive a lower bound for its radius as a function of the total spin quantum number. We also obtain a numerical estimate of this maximal radius and compare it to the case of absolutely separable states.

  9. Respiratory-Gated Helical Computed Tomography of Lung: Reproducibility of Small Volumes in an Ex Vivo Model

    SciTech Connect

    Biederer, Juergen Dinkel, Julien; Bolte, Hendrik; Welzel, Thomas; Hoffmann, Beata M.Sc.; Thierfelder, Carsten; Mende, Ulrich; Debus, Juergen; Heller, Martin; Kauczor, Hans-Ulrich

    2007-12-01

    Purpose: Motion-adapted radiotherapy with gated irradiation or tracking of tumor positions requires dedicated imaging techniques such as four-dimensional (4D) helical computed tomography (CT) for patient selection and treatment planning. The objective was to evaluate the reproducibility of spatial information for small objects on respiratory-gated 4D helical CT using computer-assisted volumetry of lung nodules in a ventilated ex vivo system. Methods and Materials: Five porcine lungs were inflated inside a chest phantom and prepared with 55 artificial nodules (mean diameter, 8.4 mm {+-} 1.8). The lungs were respirated by a flexible diaphragm and scanned with 40-row detector CT (collimation, 24 x 1.2 mm; pitch, 0.1; rotation time, 1 s; slice thickness, 1.5 mm; increment, 0.8 mm). The 4D-CT scans acquired during respiration (eight per minute) and reconstructed at 0-100% inspiration and equivalent static scans were scored for motion-related artifacts (0 or absent to 3 or relevant). The reproducibility of nodule volumetry (three readers) was assessed using the variation coefficient (VC). Results: The mean volumes from the static and dynamic inspiratory scans were equal (364.9 and 360.8 mm{sup 3}, respectively, p = 0.24). The static and dynamic end-expiratory volumes were slightly greater (371.9 and 369.7 mm{sup 3}, respectively, p = 0.019). The VC for volumetry (static) was 3.1%, with no significant difference between 20 apical and 20 caudal nodules (2.6% and 3.5%, p = 0.25). In dynamic scans, the VC was greater (3.9%, p = 0.004; apical and caudal, 2.6% and 4.9%; p = 0.004), with a significant difference between static and dynamic in the 20 caudal nodules (3.5% and 4.9%, p = 0.015). This was consistent with greater motion-related artifacts and image noise at the diaphragm (p <0.05). The VC for interobserver variability was 0.6%. Conclusion: Residual motion-related artifacts had only minimal influence on volumetry of small solid lesions. This indicates a high

  10. Variations in Target Volume Definition for Postoperative Radiotherapy in Stage III Non-Small-Cell Lung Cancer: Analysis of an International Contouring Study

    SciTech Connect

    Spoelstra, Femke; Senan, Suresh; Le Pechoux, Cecile; Ishikura, Satoshi; Casas, Francesc; Ball, David; Price, Allan; De Ruysscher, Dirk; Soernsen de Koste, John R. van

    2010-03-15

    Purpose: Postoperative radiotherapy (PORT) in patients with completely resected non-small-cell lung cancer with mediastinal involvement is controversial because of the failure of earlier trials to demonstrate a survival benefit. Improved techniques may reduce toxicity, but the treatment fields used in routine practice have not been well studied. We studied routine target volumes used by international experts and evaluated the impact of a contouring protocol developed for a new prospective study, the Lung Adjuvant Radiotherapy Trial (Lung ART). Methods and Materials: Seventeen thoracic radiation oncologists were invited to contour their routine clinical target volumes (CTV) for 2 representative patients using a validated CD-ROM-based contouring program. Subsequently, the Lung ART study protocol was provided, and both cases were contoured again. Variations in target volumes and their dosimetric impact were analyzed. Results: Routine CTVs were received for each case from 10 clinicians, whereas six provided both routine and protocol CTVs for each case. Routine CTVs varied up to threefold between clinicians, but use of the Lung ART protocol significantly decreased variations. Routine CTVs in a postlobectomy patient resulted in V{sub 20} values ranging from 12.7% to 54.0%, and Lung ART protocol CTVs resulted in values of 20.6% to 29.2%. Similar results were seen for other toxicity parameters and in the postpneumectomy patient. With the exception of upper paratracheal nodes, protocol contouring improved coverage of the required nodal stations. Conclusion: Even among experts, significant interclinician variations are observed in PORT fields. Inasmuch as contouring variations can confound the interpretation of PORT results, mandatory quality assurance procedures have been incorporated into the current Lung ART study.

  11. Investigation of the Relationship Between Gross Tumor Volume Location and Pneumonitis Rates Using a Large Clinical Database of Non-Small-Cell Lung Cancer Patients

    SciTech Connect

    Vinogradskiy, Yevgeniy; Tucker, Susan L.; Liao Zhongxing; Martel, Mary K.

    2012-04-01

    Purpose: Studies have suggested that function may vary throughout the lung, and that patients who have tumors located in the base of the lung are more susceptible to radiation pneumonitis. The purpose of our study was to investigate the relationship between gross tumor volume (GTV) location and pneumonitis rates using a large clinical database of 547 patients with non-small-cell lung cancer. Methods and Materials: The GTV centroids of all patients were mapped onto one common coordinate system, in which the boundaries of the coordinate system were defined by the extreme points of each individual patient lung. The data were qualitatively analyzed by graphing all centroids and displaying the data according to the presence of severe pneumonitis, tumor stage, and smoking status. The centroids were grouped according to superior-inferior segments, and the pneumonitis rates were analyzed. In addition, we incorporated the GTV centroid information into a Lyman-Kutcher-Burman normal tissue complication probability model and tested whether adding spatial information significantly improved the fit of the model. Results: Of the 547 patients analyzed, 111 (20.3%) experienced severe radiation pneumonitis. The pneumonitis incidence rates were 16%, 23%, and 21% for the superior, middle, and inferior thirds of the lung, respectively. Qualitatively, the GTV centroids of nonsmokers were notably absent from the superior portion of the lung. In addition, the GTV centroids of patients who had Stage III and IV clinical staging were concentrated toward the medial edge of the lung. The comparison between the GTV centroid model and the conventional dose-volume model did not yield a statistically significant difference in model fit. Conclusions: Lower pneumonitis rates were noted for the superior portion of the lung; however the differences were not statistically significant. For our patient cohort, incorporating GTV centroid information did not lead to a statistically significant improvement

  12. Prognostic factors for survival in stage III non-small-cell lung cancer treated with definitive radiation therapy: Impact of tumor volume

    SciTech Connect

    Basaki, Kiyoshi . E-mail: basaki-rad@umin.ac.jp; Abe, Yoshinao; Aoki, Masahiko; Kondo, Hidehiro; Hatayama, Yoshiomi; Nakaji, Shigeyuki

    2006-02-01

    Purpose: To investigate the impact of tumor volume on overall survival in patients with Stage III non-small-cell lung cancer (NSCLC) treated with definitive radiation therapy (RT). Methods and Materials: Between May 1997 and February 2003, 71 patients with Stage III NSCLC were treated with radiation therapy of 60 Gy or more. The total target dose was between 60 and 77 Gy (average, 66.3 Gy). Chemotherapy was used in 45 cases. The primary tumor and nodal volume were identified in pretreatment computed tomography scans. Univariate and multivariate analyses were used to evaluate the impact of tumor volume on survival after RT. Results: The overall 2-year survival rate was 23%, with a median survival time of 14 months. The median survival times were 10 months and 19 months with large primary tumor volume more than median volume and smaller primary tumor volume, respectively. At a univariate analysis, the total tumor volume (TTV) (p < 0.0003) and the primary tumor volume (p < 0.00008) were significant and the nodal volume was not. At multivariate analyses, both the TTV and the primary tumor volume were significant prognostic factors. Conclusion: The primary tumor volume as well as TTV is a significant prognostic factor on survival in patients with Stage III NSCLC treated with RT and should be recorded in clinical results when the survivals are compared among clinical studies.

  13. Long-term follow-up after bronchoscopic lung volume reduction treatment with coils in patients with severe emphysema

    PubMed Central

    Hartman, Jorine E; Klooster, Karin; Gortzak, Kiki; ten Hacken, Nick HT; Slebos, Dirk-Jan

    2015-01-01

    Background and objective Bronchoscopic lung volume reduction coil (LVR-coil) treatment has been shown to be safe and clinically effective in patients with severe emphysema in the short term; however, long-term safety and effectiveness has not been evaluated. The aim of this study was to investigate the long-term safety and effectiveness of LVR-coil treatment in patients with severe emphysema. Methods Thirty-eight patients with severe emphysema (median age is 59 years, forced expiratory volume in 1 s is 27% predicted) who were treated in LVR-coil clinical trials were invited for a voluntary annual visit. Safety was evaluated by chest X-ray and recording of adverse events and by efficacy by pulmonary function testing, 6-min walk distance (6MWD) and questionnaires. Results Thirty-five patients visited the hospital 1 year, 27 patients 2 years and 22 patients 3 years following coil placement. No coil migrations were observed on X-rays. At 1-year follow-up, all clinical outcomes significantly improved compared with baseline. At 2 years, residual volume % pred, modified Medical Research Council (mMRC) and the SGRQ score were still significantly improved. At 3 years, a significant improvement in mMRC score remained, with 40% of the patients reaching the 6MWD minimal important difference, and 59% for the St George's Respiratory Questionnaire (SGRQ) minimal important difference. Conclusions Follow-up of the patients treated with LVR-coils in our pilot studies showed that the coil treatment is safe with no late pneumothoraces, coil migrations or unexpected adverse events. Clinical benefit gradually declines over time; at 3 years post-treatment, around 50% of the patients maintained improvement in 6MWD, SGRQ and mMRC. PMID:25418910

  14. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  15. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  16. Bronchoscopic lung volume reduction by endobronchial valve in advanced emphysema: the first Asian report

    PubMed Central

    Park, Tai Sun; Hong, Yoonki; Lee, Jae Seung; Oh, Sang Young; Lee, Sang Min; Kim, Namkug; Seo, Joon Beom; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Sei Won

    2015-01-01

    Purpose Endobronchial valve (EBV) therapy is increasingly being seen as a therapeutic option for advanced emphysema, but its clinical utility in Asian populations, who may have different phenotypes to other ethnic populations, has not been assessed. Patients and methods This prospective open-label single-arm clinical trial examined the clinical efficacy and the safety of EBV in 43 consecutive patients (mean age 68.4±7.5, forced expiratory volume in 1 second [FEV1] 24.5%±10.7% predicted, residual volume 208.7%±47.9% predicted) with severe emphysema with complete fissure and no collateral ventilation in a tertiary referral hospital in Korea. Results Compared to baseline, the patients exhibited significant improvements 6 months after EBV therapy in terms of FEV1 (from 0.68±0.26 L to 0.92±0.40 L; P<0.001), 6-minute walk distance (from 233.5±114.8 m to 299.6±87.5 m; P=0.012), modified Medical Research Council dyspnea scale (from 3.7±0.6 to 2.4±1.2; P<0.001), and St George’s Respiratory Questionnaire (from 65.59±13.07 to 53.76±11.40; P=0.028). Nine patients (20.9%) had a tuberculosis scar, but these scars did not affect target lobe volume reduction or pneumothorax frequency. Thirteen patients had adverse events, ten (23.3%) developed pneumothorax, which included one death due to tension pneumothorax. Conclusion EBV therapy was as effective and safe in Korean patients as it has been shown to be in Western countries. (Trial registration: ClinicalTrials.gov: NCT01869205). PMID:26251590

  17. Application of a photogrammetric kinematic model for prediction of lung volumes in adolescents: a pilot study

    PubMed Central

    2014-01-01

    Background There are several ways to measure the respiratory system, among them inductance plethysmography and three-dimensional kinematic analysis, methods of high cost and difficult transportability. The objective of this study was to correlate respiratory volumes obtained by spirometry standard equipment with a biomechanical model photogrammetric analysis of adolescents. Methods We evaluated 50 subjects of both genders, aged between 14 and 17 years old, excluding those with respiratory obstruction or restriction. Stickers with markers, there was a five-point mapping for anatomical modeling and photogrammetry, with each evaluated in supine position, was sought to test the Forced Vital Capacity (FVC). The test was filmed and repeated three times. Images of the films were extracted for the moment of maximum exhalation and inhalation of proof with better breathing. With the use of a commercial software, defined the respiratory volumes to the thorax and abdomen. Results The photogrammetric analysis has found values strongly correlated with the spirometric measurements of FVC (0.812), forced expiratory volume in one second (FEV1 – 0.708), Peak Expiratory Flow (PEF – 0.762) in addition to post test performed Inspiration (IP- 0.816). There was a higher ventilatory mobility for boys than girls for Lower Chest and Lower and Upper Abdomen. It was possible to reach a regression R2 = 0.866 for proof of FVC and R2 = 0.776 for IP with the use of photogrammetry, presenting a standard error of 0.353 and 0.451, respectively. Conclusions Photogrammetry can be used to study thoracoabdominal movements by applying analytical two-dimensional and three-dimensional images acquired using a video camera being, applicable and reproducible. PMID:24571595

  18. The Impact of Homogeneous Versus Heterogeneous Emphysema on Dynamic Hyperinflation in Patients With Severe COPD Assessed for Lung Volume Reduction

    PubMed Central

    Boutou, Afroditi K.; Zoumot, Zaid; Nair, Arjun; Davey, Claire; Hansell, David M.; Jamurtas, Athanasios; Polkey, Michael I.; Hopkinson, Nicholas S.

    2015-01-01

    Abstract Dynamic hyperinflation (DH) is a pathophysiologic hallmark of Chronic Obstructive Pulmonary Disease (COPD). The aim of this study was to investigate the impact of emphysema distribution on DH during a maximal cardiopulmonary exercise test (CPET) in patients with severe COPD. This was a retrospective analysis of prospectively collected data among severe COPD patients who underwent thoracic high-resolution computed tomography, full lung function measurements and maximal CPET with inspiratory manouvers as assessment for a lung volume reduction procedure. ΔIC was calculated by subtracting the end-exercise inspiratory capacity (eIC) from resting IC (rIC) and expressed as a percentage of rIC (ΔIC %). Emphysema quantification was conducted at 3 predefined levels using the syngo PULMO-CT (Siemens AG); a difference >25% between best and worse slice was defined as heterogeneous emphysema. Fifty patients with heterogeneous (62.7% male; 60.9 ± 7.5 years old; FEV1% = 32.4 ± 11.4) and 14 with homogeneous emphysema (61.5% male; 62.5 ± 5.9 years old; FEV1% = 28.1 ± 10.3) fulfilled the enrolment criteria. The groups were matched for all baseline variables. ΔIC% was significantly higher in homogeneous emphysema (39.8% ± 9.8% vs.31.2% ± 13%, p = 0.031), while no other CPET parameter differed between the groups. Upper lobe predominance of emphysema correlated positively with peak oxygen pulse, peak oxygen uptake and peak respiratory rate, and negatively with ΔIC%. Homogeneous emphysema is associated with more DH during maximum exercise in COPD patients. PMID:26398112

  19. Total Gross Tumor Volume Is an Independent Prognostic Factor in Patients Treated With Selective Nodal Irradiation for Stage I to III Small Cell Lung Cancer

    SciTech Connect

    Reymen, Bart; Van Loon, Judith; Baardwijk, Angela van; Wanders, Rinus; Borger, Jacques; Dingemans, Anne-Marie C.; Bootsma, Gerben; Pitz, Cordula; Lunde, Ragnar; Geraedts, Wiel; Lambin, Philippe; De Ruysscher, Dirk

    2013-04-01

    Purpose: In non-small cell lung cancer, gross tumor volume (GTV) influences survival more than other risk factors. This could also apply to small cell lung cancer. Methods and Materials: Analysis of our prospective database with stage I to III SCLC patients referred for concurrent chemo radiation therapy. Standard treatment was 45 Gy in 1.5-Gy fractions twice daily concurrently with carboplatin-etoposide, followed by prophylactic cranial irradiation (PCI) in case of non-progression. Only fluorodeoxyglucose (FDG)-positron emission tomography (PET)-positive or pathologically proven nodal sites were included in the target volume. Total GTV consisted of post chemotherapy tumor volume and pre chemotherapy nodal volume. Survival was calculated from diagnosis (Kaplan-Meier ). Results: A total of 119 patients were included between May 2004 and June 2009. Median total GTV was 93 ± 152 cc (7.5-895 cc). Isolated elective nodal failure occurred in 2 patients (1.7%). Median follow-up was 38 months, median overall survival 20 months (95% confidence interval = 17.8-22.1 months), and 2-year survival 38.4%. In multivariate analysis, only total GTV (P=.026) and performance status (P=.016) significantly influenced survival. Conclusions: In this series of stage I to III small cell lung cancer patients treated with FDG-PET-based selective nodal irradiation total GTV is an independent risk factor for survival.

  20. Sci—Fri AM: Mountain — 06: Optimizing planning target volume in lung radiotherapy using deformable registration

    SciTech Connect

    Hoang, P; Wierzbicki, M

    2014-08-15

    A four dimensional computed tomography (4DCT) image is acquired for all radically treated, lung cancer patients to define the internal target volume (ITV), which encompasses tumour motion due to breathing and subclinical disease. Patient set-up error and anatomical motion that is not due to breathing is addressed through an additional 1 cm margin around the ITV to obtain the planning target volume (PTV). The objective of this retrospective study is to find the minimum PTV margin that provides an acceptable probability of delivering the prescribed dose to the ITV. Acquisition of a kV cone beam computed tomography (CBCT) image at each fraction was used to shift the treatment couch to accurately align the spinal cord and carina. Our method utilized deformable image registration to automatically position the planning ITV on each CBCT. We evaluated the percentage of the ITV surface that fell within various PTVs for 79 fractions across 18 patients. Treatment success was defined as a situation where at least 99% of the ITV is covered by the PTV. Overall, this is to be achieved in at least 90% of the treatment fractions. The current approach with a 1cm PTV margin was successful ∼96% of the time. This analysis revealed that the current margin can be reduced to 0.8cm isotropic or 0.6×0.6×1 cm{sup 3} non-isotropic, which were successful 92 and 91 percent of the time respectively. Moreover, we have shown that these margins maintain accuracy, despite intrafractional variation, and maximize CBCT image guidance capabilities.

  1. Improved CT-based estimate of pulmonary gas trapping accounting for scanner and lung-volume variations in a multicenter asthmatic study.

    PubMed

    Choi, Sanghun; Hoffman, Eric A; Wenzel, Sally E; Castro, Mario; Lin, Ching-Long

    2014-09-15

    Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions.

  2. Chest Wall Volume Receiving >30 Gy Predicts Risk of Severe Pain and/or Rib Fracture After Lung Stereotactic Body Radiotherapy

    SciTech Connect

    Dunlap, Neal E.; Cai, Jing; Biedermann, Gregory B.; Yang, Wensha; Benedict, Stanley H.; Sheng Ke; Schefter, Tracey E.; Kavanagh, Brian D.; Larner, James M.

    2010-03-01

    Purpose: To identify the dose-volume parameters that predict the risk of chest wall (CW) pain and/or rib fracture after lung stereotactic body radiotherapy. Methods and Materials: From a combined, larger multi-institution experience, 60 consecutive patients treated with three to five fractions of stereotactic body radiotherapy for primary or metastatic peripheral lung lesions were reviewed. CW pain was assessed using the Common Toxicity Criteria for pain. Peripheral lung lesions were defined as those located within 2.5 cm of the CW. A minimal point dose of 20 Gy to the CW was required. The CW volume receiving >=20, >=30, >=40, >=50, and >=60 Gy was determined and related to the risk of CW toxicity. Results: Of the 60 patients, 17 experienced Grade 3 CW pain and five rib fractures. The median interval to the onset of severe pain and/or fracture was 7.1 months. The risk of CW toxicity was fitted to the median effective concentration dose-response model. The CW volume receiving 30 Gy best predicted the risk of severe CW pain and/or rib fracture (R{sup 2} = 0.9552). A volume threshold of 30 cm{sup 3} was observed before severe pain and/or rib fracture was reported. A 30% risk of developing severe CW toxicity correlated with a CW volume of 35 cm{sup 3} receiving 30 Gy. Conclusion: The development of CW toxicity is clinically relevant, and the CW should be considered an organ at risk in treatment planning. The CW volume receiving 30 Gy in three to five fractions should be limited to <30 cm{sup 3}, if possible, to reduce the risk of toxicity without compromising tumor coverage.

  3. Impact of FDG-PET/CT on Radiotherapy Volume Delineation in Non-Small-Cell Lung Cancer and Correlation of Imaging Stage With Pathologic Findings

    SciTech Connect

    Faria, Sergio L. Menard, Sonia; Devic, Slobodan; Sirois, Christian; Souhami, Luis; Lisbona, Robert; Freeman, Carolyn R.

    2008-03-15

    Purpose: Fluorodeoxyglucose-positron emission tomography (FDG-PET)/computed tomography (CT) is more accurate than CT in determining the extent of non-small-cell lung cancer. We performed a study to evaluate the impact of FDG-PET/CT on the radiotherapy volume delineation compared with CT without using any mathematical algorithm and to correlate the findings with the pathologic examination findings. Methods and Materials: A total of 32 patients with proven non-small-cell lung cancer, pathologic specimens from the mediastinum and lung primary, and pretreatment chest CT and FDG-PET/CT scans were studied. For each patient, two data sets of theoretical gross tumor volumes were contoured. One set was determined using the chest CT only, and the second, done separately, was based on the co-registered FDG-PET/CT data. The disease stage of each patient was determined using the TNM staging system for three data sets: the CT scan only, FDG-PET/CT scan, and pathologic findings. Results: Pathologic examination altered the CT-determined stage in 22 (69%) of 32 patients and the PET-determined stage in 16 (50%) of 32 patients. The most significant alterations were related to the N stage. PET altered the TNM stage in 15 (44%) of 32 patients compared with CT alone, but only 7 of these 15 alterations were confirmed by the pathologic findings. With respect to contouring the tumor volume for radiotherapy, PET altered the contour in 18 (56%) of 32 cases compared with CT alone. Conclusion: The contour of the tumor volume of non-small-cell lung cancer patients with co-registered FDG-PET/CT resulted in >50% alterations compared with CT targeting, findings similar to those of other publications. However, the significance of this change is unknown. Furthermore, pathologic examination showed that PET is not always accurate and histologic examination should be obtained to confirm the findings of PET whenever possible.

  4. Evaluation of residual functional lung volume on Tc-99m DTPA aerosol ventilation and Tc-99m MAA perfusion scintigraphy in primary ciliary dyskinesia (Kartagener syndrome).

    PubMed

    Chen, Yu-Wen; Chang, Chin-Chuan; Lai, Yung-Chuang; Lu, Chia-Ying; Dai, Zen-Kong

    2008-12-01

    Kartagener syndrome is diagnosed as sinusitis, bronchitis (bronchiectasis), and situs inversus by the clinical features. It is a subclass of primary ciliary dyskinesia (PCD) disease. A 12-year-old girl who had frequent upper and lower airway infections since birth, which was confirmed as Kartagener syndrome by HRCT imaging. We present the residual functional lung volume and mucociliary clearance findings seen on Tc-99m DTPA aerosol ventilation and Tc-99m MAA perfusion scintigraphy.

  5. SU-E-T-427: Cell Surviving Fractions Derived From Tumor-Volume Variation During Radiotherapy for Non-Small Cell Lung Cancer: Comparison with Predictive Assays

    SciTech Connect

    Chvetsov, A; Schwartz, J; Mayr, N; Yartsev, S

    2014-06-01

    Purpose: To show that a distribution of cell surviving fractions S{sub 2} in a heterogeneous group of patients can be derived from tumor-volume variation curves during radiotherapy for non-small cell lung cancer. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage (MV) computed tomography (CT). Statistical distributions of cell surviving fractions S{sup 2} and cell clearance half-lives of lethally damaged cells T1/2 have been reconstructed in each patient group by using a version of the two-level cell population tumor response model and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Non-small cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractions S{sub 2} for non-small cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sup 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Comparison of the reconstructed cell surviving fractions with patient survival data shows that the patient survival time decreases as the cell surviving fraction increases. Conclusion: The data obtained in this work suggests that the cell surviving fractions S{sub 2} can be reconstructed from the tumor volume

  6. Segmental bronchi collapsibility: computed tomography-based quantification in patients with chronic obstructive pulmonary disease and correlation with emphysema phenotype, corresponding lung volume changes and clinical parameters

    PubMed Central

    Thaiss, Wolfgang Maximilian; Ditt, Hendrik; Hetzel, Jürgen; Schülen, Eva; Nikolaou, Konstantin; Horger, Marius

    2016-01-01

    Background Global pulmonary function tests lack region specific differentiation that might influence therapy in severe chronic obstructive pulmonary disease (COPD) patients. Therefore, the aim of this work was to assess the degree of expiratory 3rd generation bronchial lumen collapsibility in patients with severe COPD using chest-computed tomography (CT), to evaluate emphysema-phenotype, lobar volumes and correlate results with pulmonary function tests. Methods Thin-slice chest-CTs acquired at end-inspiration & end-expiration in 42 COPD GOLD IV patients (19 females, median-age: 65.9 y) from November 2011 to July 2014 were re-evaluated. The cross-sectional area of all segmental bronchi was measured 5 mm below the bronchial origin in both examinations. Lung lobes were semi-automatically segmented, volumes calculated at end-inspiratory and end-expiratory phase and visually defined emphysema-phenotypes defined. Results of CT densitometry were compared with lung functional tests including forced expiratory volume at 1 s (FEV1), total lung capacity (TLC), vital capacity (VC), residual volume (RV), diffusion capacity parameters and the maximal expiratory flow rates (MEFs). Results Mean expiratory bronchial collapse was 31%, stronger in lobes with homogenous (38.5%) vs. heterogeneous emphysema-phenotype (27.8%, P=0.014). The mean lobar expiratory volume reduction was comparable in both emphysema-phenotypes (volume reduction 18.6%±8.3% in homogenous vs. 17.6%±16.5% in heterogeneous phenotype). The degree of bronchial lumen collapsibility, did not correlate with expiratory volume reduction. MEF25 correlated weakly with 3rd generation airway collapsibility (r=0.339, P=0.03). All patients showed a concentric expiratory reduction of bronchial cross-sectional area. Conclusions Changes in collapsibility of 3rd generation bronchi in COPD grade IV patients is significantly lower than that in the trachea and the main bronchi. Collapsibility did not correlate with the reduction in

  7. Automated compromised right lung segmentation method using a robust atlas-based active volume model with sparse shape composition prior in CT.

    PubMed

    Zhou, Jinghao; Yan, Zhennan; Lasio, Giovanni; Huang, Junzhou; Zhang, Baoshe; Sharma, Navesh; Prado, Karl; D'Souza, Warren

    2015-12-01

    To resolve challenges in image segmentation in oncologic patients with severely compromised lung, we propose an automated right lung segmentation framework that uses a robust, atlas-based active volume model with a sparse shape composition prior. The robust atlas is achieved by combining the atlas with the output of sparse shape composition. Thoracic computed tomography images (n=38) from patients with lung tumors were collected. The right lung in each scan was manually segmented to build a reference training dataset against which the performance of the automated segmentation method was assessed. The quantitative results of this proposed segmentation method with sparse shape composition achieved mean Dice similarity coefficient (DSC) of (0.72, 0.81) with 95% CI, mean accuracy (ACC) of (0.97, 0.98) with 95% CI, and mean relative error (RE) of (0.46, 0.74) with 95% CI. Both qualitative and quantitative comparisons suggest that this proposed method can achieve better segmentation accuracy with less variance than other atlas-based segmentation methods in the compromised lung segmentation.

  8. Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype

    PubMed Central

    Yin, Yan; Hou, Gang; Herth, Felix J; Wang, Xiao-bo; Wang, Qiu-yue; Kang, Jian

    2016-01-01

    Satisfactory functional outcomes following bronchoscopic lung volume reduction (BLVR) using endobronchial valves (EBVs) depend on the absence of collateral ventilation (CV) between the target and adjunct lobes. The Chartis system has proven to be useful for determining whether CV is present or absent, but this system can also erroneously indicate the absence of CV, which can lead to BLVR failure. Here, we describe low-flow Chartis phenotype in the target lobe resulted in difficult judgment of existence of CV. Consequently, BLVR with EBVs implanted into the right upper bronchus failed to reduce lung volume or induce atelectasis. Inserting another EBV into the right middle bronchus blocked the latent CV, which led to significant lung volume reduction in the right upper lobe (RUL) and right middle lobe (RML) and to improve the pulmonary function, 6-min walking distance, and St George respiratory questionnaire scores over a 2-week follow-up period. Low flow in the target lobe is a unique Chartis phenotype and represents the uncertainty of CV, which is a risk factor for the failure of BLVR using EBVs. Clinicians should be aware of this possibility and might be able to resolve the problem by blocking the RUL and RML between which the CV occurs. PMID:27920518

  9. A new method to deliver supraclavicular radiation in breast radiotherapy for lung sparing.

    PubMed

    Yang, Bo; Dong, Zhang; Lin, Mu-Han; Ma, C-M

    2011-04-18

    Due to the angulation of the breast board used for tangential breast irradiation, additional normal lung tissues are included in the supraclavicular field. This work investigates a method to reduce the lung volume and dose delivered during supraclavicular irradiation for breast cancer. Ten patients included for this retrospective study received chest wall and supraclavicular irradiation following radical surgery or breast-conserving surgery. Three-dimensional conformal radiation therapy plans were generated using the CMS XiO treatment planning system. The clinical target volume (CTV) of the supraclavicular irradiation is defined as the subcutaneous tissues from 0.5 cm under the anterior skin surface to a 3 cm depth. Only the ipsilateral lung is defined as the organ at risk. In the new method, the couch is rotated 90° and the supraclavicular field is tilted to maintain a normal incident angle to the breast board rather than the couch surface to spare more normal lung tissues. The absolute volume of the ipsilateral lung irradiated, and the volumes of lung tissues receiving 5 Gy and 20 Gy (V5 and V20) are analyzed. The new method can reduce the lung volume irradiated by the supraclavicular field significantly. For the ten patients investigated, only 5.3% of the ipsilateral lung is irradiated with the new method, while 14.9% of the ipsilateral lung is irradiated using the conventional method. Compared with the conventional method, the new method reduces V5 by 53.6% and V20 by 59.0%. Our new method does not alter the patient positioning for breast treatment but rotates the couch to deliver a tilted supraclavicular field to maintain adequate CTV coverage and spare more normal lung tissues. The results of this study demonstrated that our new method is effective, and that the reduction of normal lung tissue volume in the field is significant.

  10. Automated detection and delineation of lung tumors in PET-CT volumes using a lung atlas and iterative mean-SUV threshold

    NASA Astrophysics Data System (ADS)

    Ballangan, Cherry; Wang, Xiuying; Eberl, Stefan; Fulham, Michael; Feng, Dagan

    2009-02-01

    Automated segmentation for the delineation of lung tumors with PET-CT is a challenging task. In PET images, primary lung tumors can have varying degrees of tracer uptake, which sometimes does not differ markedly from normal adjacent structures such as the mediastinum, heart and liver. In addition, separation of tumor from adjacent soft tissues and bone in the chest wall is problematic due to limited resolution. For CT, the tumor soft tissue density can be similar to that in the blood vessels and the chest wall; and although CT provides better boundary definition, exact tumor delineation is also difficult when the tumor density is similar to adjacent structures. We propose an innovative automated adaptive method to delineate lung tumors in PET-CT images in conjunction with a lung atlas in which an iterative mean-SUV (Standardized Uptake Value) threshold is used to gradually define the tumor region in PET. Tumor delineation in the CT data is performed using region growing and seeds obtained autonomously from the PET tumor regions. We evaluated our approach in 13 patients with non-small cell lung cancer (NSCLC) and found it could delineate tumors of different size, shape and location, even when when the NSCLC involved the chest wall.

  11. SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

    SciTech Connect

    Soultan, D; Murphy, J; James, C; Hoh, C; Moiseenko, V; Cervino, L; Gill, B

    2015-06-15

    Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images were binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.

  12. Dead space reduction by Kolobow's endotracheal tube does not justify the waiving of volume monitoring in small, ventilated lungs.

    PubMed

    Proquitté, Hans; Wendel, Rena; Roehr, Charles C; Wauer, Roland R; Schmalisch, Gerd

    2014-12-01

    In ventilated preterm infants the flow sensor contributes significantly to the total apparatus dead space, which may impair gas exchange. The aim of the study was to quantify to which extent a dead space reduced Kolobow tube (KB) without flow sensor improves the gas exchange compared with a conventional ventilator circuit with flow sensor [Babylog 8000 (BL)]. In a cross-over trial in 14 tracheotomized, surfactant-depleted (saline lavage) and mechanically ventilated newborn piglets (age <12 h; body weight 705-1200 g) BL and KB was applied alternately for 15 min and blood gases were recorded. The inner diameter of the endotracheal tube was 3.6 mm and the apparatus dead space of BL and KB including the endotracheal tube were 3.0 and 1.34 mL. Despite a 50 % apparatus dead space reduction with KB compared to BL statistically significant improvements were only observed for body weights <900 g. In this weight group median paCO2 was decreased by 5 mmHg (p < 0.01), whereas the improvement decreased with decreasing baseline paCO2. Furthermore, median paO2 was increased by 4 mmHg (p < 0.05) and O2 saturation was increased by 2.5 % (p < 0.05). No significant changes were seen in the circulatory parameters. In very small, ventilated lungs the use of KB improved the gas exchange; however, the improvement was moderate and does not justify the waiving of volume monitoring.

  13. Do Sustained Lung Inflations during Neonatal Resuscitation Affect Cerebral Blood Volume in Preterm Infants? A Randomized Controlled Pilot Study

    PubMed Central

    Schwaberger, Bernhard; Pichler, Gerhard; Avian, Alexander; Binder-Heschl, Corinna; Baik, Nariae; Urlesberger, Berndt

    2015-01-01

    Background Sustained lung inflations (SLI) during neonatal resuscitation may promote alveolar recruitment in preterm infants. While most of the studies focus on respiratory outcome, the impact of SLI on the brain hasn’t been investigated yet. Objective Do SLI affect cerebral blood volume (CBV) in preterm infants? Methods Preterm infants of gestation 28 weeks 0 days to 33 weeks 6 days with requirement for respiratory support (RS) were included in this randomized controlled pilot trial. Within the first 15 minutes after birth near-infrared spectroscopy (NIRS) measurements using ‘NIRO-200-NX’ (Hamamatsu, Japan) were performed to evaluate changes in CBV and cerebral tissue oxygenation. Two groups were compared based on RS: In SLI group RS was given by applying 1–3 SLI (30 cmH2O for 15 s) continued by respiratory standard care. Control group received respiratory standard care only. Results 40 infants (20 in each group) with mean gestational age of 32 weeks one day (±2 days) and birth weight of 1707 (±470) g were included. In the control group ΔCBV was significantly decreasing, whereas in SLI group ΔCBV showed similar values during the whole period of 15 minutes. Comparing both groups within the first 15 minutes ΔCBV showed a tendency toward different overall courses (p = 0.051). Conclusion This is the first study demonstrating an impact of SLI on CBV. Further studies are warranted including reconfirmation of the present findings in infants with lower gestational age. Future investigations on SLI should not only focus on respiratory outcome but also on the consequences on the developing brain. Trial Registration German Clinical Trials Register DRKS00005161 https://drks-neu.uniklinik-freiburg.de/drks_web/setLocale_EN.do PMID:26406467

  14. Absolute and relative blindsight.

    PubMed

    Balsdon, Tarryn; Azzopardi, Paul

    2015-03-01

    The concept of relative blindsight, referring to a difference in conscious awareness between conditions otherwise matched for performance, was introduced by Lau and Passingham (2006) as a way of identifying the neural correlates of consciousness (NCC) in fMRI experiments. By analogy, absolute blindsight refers to a difference between performance and awareness regardless of whether it is possible to match performance across conditions. Here, we address the question of whether relative and absolute blindsight in normal observers can be accounted for by response bias. In our replication of Lau and Passingham's experiment, the relative blindsight effect was abolished when performance was assessed by means of a bias-free 2AFC task or when the criterion for awareness was varied. Furthermore, there was no evidence of either relative or absolute blindsight when both performance and awareness were assessed with bias-free measures derived from confidence ratings using signal detection theory. This suggests that both relative and absolute blindsight in normal observers amount to no more than variations in response bias in the assessment of performance and awareness. Consideration of the properties of psychometric functions reveals a number of ways in which relative and absolute blindsight could arise trivially and elucidates a basis for the distinction between Type 1 and Type 2 blindsight.

  15. Absolute neutrino mass scale

    NASA Astrophysics Data System (ADS)

    Capelli, Silvia; Di Bari, Pasquale

    2013-04-01

    Neutrino oscillation experiments firmly established non-vanishing neutrino masses, a result that can be regarded as a strong motivation to extend the Standard Model. In spite of being the lightest massive particles, neutrinos likely represent an important bridge to new physics at very high energies and offer new opportunities to address some of the current cosmological puzzles, such as the matter-antimatter asymmetry of the Universe and Dark Matter. In this context, the determination of the absolute neutrino mass scale is a key issue within modern High Energy Physics. The talks in this parallel session well describe the current exciting experimental activity aiming to determining the absolute neutrino mass scale and offer an overview of a few models beyond the Standard Model that have been proposed in order to explain the neutrino masses giving a prediction for the absolute neutrino mass scale and solving the cosmological puzzles.

  16. The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy

    SciTech Connect

    Clements, N.; Kron, T.; Roxby, P.; Franich, R.; Dunn, L.; Aarons, Y.; Chesson, B.; Siva, S.; Duplan, D.; Ball, D.

    2013-02-15

    Purpose: Stereotactic lung radiotherapy is complicated by tumor motion from patient respiration. Four-dimensional CT (4DCT) imaging is a motion compensation method used in treatment planning to generate a maximum intensity projection (MIP) internal target volume (ITV). Image guided radiotherapy during treatment may involve acquiring a volumetric cone-beam CT (CBCT) image and visually aligning the tumor to the planning 4DCT MIP ITV contour. Moving targets imaged with CBCT can appear blurred and currently there are no studies reporting on the effect that irregular breathing patterns have on CBCT volumes and their alignment to 4DCT MIP ITV contours. The objective of this work was therefore to image a phantom moving with irregular breathing patterns to determine whether any configurations resulted in errors in volume contouring or alignment. Methods: A Perspex thorax phantom was used to simulate a patient. Three wooden 'lung' inserts with embedded Perspex 'lesions' were moved up to 4 cm with computer-generated motion patterns, and up to 1 cm with patient-specific breathing patterns. The phantom was imaged on 4DCT and CBCT with the same acquisition settings used for stereotactic lung patients in the clinic and the volumes on all phantom images were contoured. This project assessed the volumes for qualitative and quantitative changes including volume, length of the volume, and errors in alignment between CBCT volumes and 4DCT MIP ITV contours. Results: When motion was introduced 4DCT and CBCT volumes were reduced by up to 20% and 30% and shortened by up to 7 and 11 mm, respectively, indicating that volume was being under-represented at the extremes of motion. Banding artifacts were present in 4DCT MIP images, while CBCT volumes were largely reduced in contrast. When variable amplitudes from patient traces were used and CBCT ITVs were compared to 4DCT MIP ITVs there was a distinct trend in reduced ITV with increasing amplitude that was not seen when compared to true ITVs

  17. The absolute path command

    SciTech Connect

    Moody, A.

    2012-05-11

    The ap command traveres all symlinks in a given file, directory, or executable name to identify the final absolute path. It can print just the final path, each intermediate link along with the symlink chan, and the permissions and ownership of each directory component in the final path. It has functionality similar to "which", except that it shows the final path instead of the first path. It is also similar to "pwd", but it can provide the absolute path to a relative directory from the current working directory.

  18. SU-E-J-179: Assessment of Tumor Volume Change and Movement During Stereotactic Body Radiotherapy (SBRT) for Lung Cancer: Is Adaptive Radiation Therapy (ART) Necessary?

    SciTech Connect

    Lee, C; Lee, C

    2015-06-15

    Purpose: Delineation of gross tumor volumes (GTVs) is important for stereotactic body radiotherapy (SBRT). However, tumor volume changes during treatment response. Here, we have investigated tumor volume changes and movement during SBRT for lung cancer, as a means of examining the need for adaptive radiation therapy (ART). Methods: Fifteen tumors in 15 patients with lung cancer were treated with SBRT (total dose: 60 Gy in 4 fractions). GTVs were obtained from cone-beam computed tomography scans (CBCT1–4) taken before each of the 4 fractions was administered. GTVs were delineated and measured by radiation oncologists using a treatment planning system. Variance in the tumor position was assessed between the planning CT and the CBCT images. To investigate the dosimetric effects of tumor volume changes, planning CT and CBCT4 treatment plans were compared using the conformity index (CI), homogeneity index (HI), and Paddick’s index (PCI). Results: The GTV on CBCT1 was employed as a baseline for comparisons. GTV had decreased by a mean of 20.4% (range: 0.7% to 47.2%) on CBCT4. Most patients had smaller GTVs on CBCT4 than on CBCT1. The interfractional shifts of the tumor position between the planning CT and CBCT1–4 were as follows: right-left, −0.4 to 1.3 mm; anterior-posterior, −0.8 to 0.5 mm; and superiorinferior, −0.9 to 1.1 mm. Indices for plans from the planning CT and CBCT4 were as follows: CI = 0.94±0.02 and 1.11±0.03; HI= 1.1±0.02 and 1.10±0.03; and PCI = 1.35±0.16 and 1.11±0.02, respectively. Conclusion: CI, HI, and PCI did not differ between the planning CT and CBCTs. However, daily CBCT revealed a significant decrease in the GTV during lung SBRT. Furthermore, there was an obvious interfractional shift in tumor position. Using ART could potentially lead to a reduced GTV margin and improved regional tumor control for lung cancer patients with significantly decreased GTV.

  19. Symposium Entitled: Particle Lung Interactions: ’Overload’ Related Phenomena. A Journal of Aerosol Medicine - Deposition, Clearance, and Effects in the Lung. Volume 3, Supplement 1

    DTIC Science & Technology

    1991-04-01

    J.B., MCGANDY R.B. and KENNEDY A.R. (1978). Interactions Between Polonium - 210 Alpha-Radiation, Benzo(a)pyrene, and 0.9% NaCl Solution Instillations in...Interactions: Lung Fibrogenesis By J. A. LAST, R. WU, J. CHEN, T. GELZLEICHTER, W.-M. SUN, and L.G. ARMSTRONG S-61 Antioxidant Defense Mechanisms in Asbestos ...Perhaps future studies on mechanisms underlying events occurring after low level exposure to toxic particles such as quartz or even asbestos fibers

  20. PREOPERATIVE PREDICTION OF LUNG FUNCTION IN PNEUMONECTOMY BY SPIROMETRY AND LUNG PERFUSION SCINTIGRAPHY

    PubMed Central

    Cukic, Vesna

    2012-01-01

    Introduction: Nowadays an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused by common etiologic factor - smoking cigarettes. Loss of lung tissue in such patients can worsen much the postoperative pulmonary function. So it is necessary to asses the postoperative pulmonary function especially after maximal resection, i.e. pneumonectomy. Objective: To check over the accuracy of preoperative prognosis of postoperative lung function after pneumonectomy using spirometry and lung perfusion scinigraphy. Material and methods: The study was done on 17 patients operated at the Clinic for thoracic surgery, who were treated previously at the Clinic for Pulmonary Diseases “Podhrastovi” in the period from 01. 12. 2008. to 01. 06. 2011. Postoperative pulmonary function expressed as ppoFEV1 (predicted postoperative forced expiratory volume in one second) was prognosticated preoperatively using spirometry, i.e.. simple calculation according to the number of the pulmonary segments to be removed and perfusion lung scintigraphy. Results: There is no significant deviation of postoperative achieved values of FEV1 from predicted ones obtained by both methods, and there is no significant differences between predicted values (ppoFEV1) obtained by spirometry and perfusion scintigraphy. Conclusion: It is necessary to asses the postoperative pulmonary function before lung resection to avoid postoperative respiratory failure and other cardiopulmonary complications. It is absolutely necessary for pneumonectomy, i.e.. maximal pulmonary resection. It can be done with great possibility using spirometry or perfusion lung scintigraphy. PMID:23378687

  1. Late-Course Adaptive Adjustment Based on Metabolic Tumor Volume Changes during Radiotherapy May Reduce Radiation Toxicity in Patients with Non-Small Cell Lung Cancer

    PubMed Central

    Zhang, Guifang; Zhang, Hui; Gao, Song; Fu, Zheng; Wang, Suzhen; Yu, Qingxi; Yu, Jinming; Yuan, Shuanghu

    2017-01-01

    To reduce the high risk of radiation toxicity and enhance the quality of life of patients with non-small cell lung cancer (NSCLC), we quantified the metabolic tumor volumes (MTVs) from baseline to the late-course of radiotherapy (RT) by fluorodeoxyglucose positron emission tomography computerized tomography (FDG PET-CT) and discussed the potential benefit of late-course adaptive plans rather than original plans by dose volume histogram (DVH) comparisons. Seventeen patients with stage II-III NSCLC who were treated with definitive conventionally fractionated RT were eligible for this prospective study. FDG PET-CT scans were acquired within 1 week before RT (pre-RT) and at approximately two-thirds of the total dose during-RT (approximately 40 Gy). MTVs were taken as gross tumor volumes (GTVs) that included the primary tumor and any involved hilar or mediastinal lymph nodes. An original plan based on the baseline MTVs and adaptive plans based on observations during-RT MTVs were generated for each patient. The DVHs for lung, heart, esophagus and spinal cord were compared between the original plans and composite plans at 66 Gy. At the time of approximately 40 Gy during-RT, MTVs were significantly reduced in patients with NSCLC (pre-RT 136.2±82.3 ml vs. during-RT 64.7±68.0 ml, p = 0.001). The composite plan of the original plan at 40 Gy plus the adaptive plan at 26 Gy resulted in better DVHs for all the organs at risk that were evaluated compared to the original plan at 66 Gy (p<0.05), including V5, V10, V15, V20, V25, V30 and the mean dose of total lung, V10, V20, V30, V40, V50, V60 and the mean dose of heart, V35, V40, V50, V55, V60, the maximum dose and mean dose of the esophagus, and the maximum dose of the spinal-cord. PET-MTVs were reduced significantly at the time of approximately 40 Gy during-RT. Late course adaptive radiotherapy may be an effective way to reduce the dose volume to the organs at risk, thus reducing radiation toxicity in patients with NSCLC. PMID

  2. Late-Course Adaptive Adjustment Based on Metabolic Tumor Volume Changes during Radiotherapy May Reduce Radiation Toxicity in Patients with Non-Small Cell Lung Cancer.

    PubMed

    Xiao, Linlin; Liu, Ning; Zhang, Guifang; Zhang, Hui; Gao, Song; Fu, Zheng; Wang, Suzhen; Yu, Qingxi; Yu, Jinming; Yuan, Shuanghu

    2017-01-01

    To reduce the high risk of radiation toxicity and enhance the quality of life of patients with non-small cell lung cancer (NSCLC), we quantified the metabolic tumor volumes (MTVs) from baseline to the late-course of radiotherapy (RT) by fluorodeoxyglucose positron emission tomography computerized tomography (FDG PET-CT) and discussed the potential benefit of late-course adaptive plans rather than original plans by dose volume histogram (DVH) comparisons. Seventeen patients with stage II-III NSCLC who were treated with definitive conventionally fractionated RT were eligible for this prospective study. FDG PET-CT scans were acquired within 1 week before RT (pre-RT) and at approximately two-thirds of the total dose during-RT (approximately 40 Gy). MTVs were taken as gross tumor volumes (GTVs) that included the primary tumor and any involved hilar or mediastinal lymph nodes. An original plan based on the baseline MTVs and adaptive plans based on observations during-RT MTVs were generated for each patient. The DVHs for lung, heart, esophagus and spinal cord were compared between the original plans and composite plans at 66 Gy. At the time of approximately 40 Gy during-RT, MTVs were significantly reduced in patients with NSCLC (pre-RT 136.2±82.3 ml vs. during-RT 64.7±68.0 ml, p = 0.001). The composite plan of the original plan at 40 Gy plus the adaptive plan at 26 Gy resulted in better DVHs for all the organs at risk that were evaluated compared to the original plan at 66 Gy (p<0.05), including V5, V10, V15, V20, V25, V30 and the mean dose of total lung, V10, V20, V30, V40, V50, V60 and the mean dose of heart, V35, V40, V50, V55, V60, the maximum dose and mean dose of the esophagus, and the maximum dose of the spinal-cord. PET-MTVs were reduced significantly at the time of approximately 40 Gy during-RT. Late course adaptive radiotherapy may be an effective way to reduce the dose volume to the organs at risk, thus reducing radiation toxicity in patients with NSCLC.

  3. Electronic Absolute Cartesian Autocollimator

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.

    2006-01-01

    An electronic absolute Cartesian autocollimator performs the same basic optical function as does a conventional all-optical or a conventional electronic autocollimator but differs in the nature of its optical target and the manner in which the position of the image of the target is measured. The term absolute in the name of this apparatus reflects the nature of the position measurement, which, unlike in a conventional electronic autocollimator, is based absolutely on the position of the image rather than on an assumed proportionality between the position and the levels of processed analog electronic signals. The term Cartesian in the name of this apparatus reflects the nature of its optical target. Figure 1 depicts the electronic functional blocks of an electronic absolute Cartesian autocollimator along with its basic optical layout, which is the same as that of a conventional autocollimator. Referring first to the optical layout and functions only, this or any autocollimator is used to measure the compound angular deviation of a flat datum mirror with respect to the optical axis of the autocollimator itself. The optical components include an illuminated target, a beam splitter, an objective or collimating lens, and a viewer or detector (described in more detail below) at a viewing plane. The target and the viewing planes are focal planes of the lens. Target light reflected by the datum mirror is imaged on the viewing plane at unit magnification by the collimating lens. If the normal to the datum mirror is parallel to the optical axis of the autocollimator, then the target image is centered on the viewing plane. Any angular deviation of the normal from the optical axis manifests itself as a lateral displacement of the target image from the center. The magnitude of the displacement is proportional to the focal length and to the magnitude (assumed to be small) of the angular deviation. The direction of the displacement is perpendicular to the axis about which the

  4. Absolute airborne gravimetry

    NASA Astrophysics Data System (ADS)

    Baumann, Henri

    This work consists of a feasibility study of a first stage prototype airborne absolute gravimeter system. In contrast to relative systems, which are using spring gravimeters, the measurements acquired by absolute systems are uncorrelated and the instrument is not suffering from problems like instrumental drift, frequency response of the spring and possible variation of the calibration factor. The major problem we had to resolve were to reduce the influence of the non-gravitational accelerations included in the measurements. We studied two different approaches to resolve it: direct mechanical filtering, and post-processing digital compensation. The first part of the work describes in detail the different mechanical passive filters of vibrations, which were studied and tested in the laboratory and later in a small truck in movement. For these tests as well as for the airborne measurements an absolute gravimeter FG5-L from Micro-G Ltd was used together with an Inertial navigation system Litton-200, a vertical accelerometer EpiSensor, and GPS receivers for positioning. These tests showed that only the use of an optical table gives acceptable results. However, it is unable to compensate for the effects of the accelerations of the drag free chamber. The second part describes the strategy of the data processing. It is based on modeling the perturbing accelerations by means of GPS, EpiSensor and INS data. In the third part the airborne experiment is described in detail, from the mounting in the aircraft and data processing to the different problems encountered during the evaluation of the quality and accuracy of the results. In the part of data processing the different steps conducted from the raw apparent gravity data and the trajectories to the estimation of the true gravity are explained. A comparison between the estimated airborne data and those obtained by ground upward continuation at flight altitude allows to state that airborne absolute gravimetry is feasible and

  5. Correlation of 18F-FDG Avid Volumes on Pre–Radiation Therapy and Post–Radiation Therapy FDG PET Scans in Recurrent Lung Cancer

    PubMed Central

    Shusharina, Nadya; Cho, Joseph; Sharp, Gregory C.; Choi, Noah C.

    2014-01-01

    Purpose To investigate the spatial correlation between high uptake regions of 2-deoxy-2-[18F]-fluoro-D-glucose positron emission tomography (18F-FDG PET) before and after therapy in recurrent lung cancer. Methods and Materials We enrolled 106 patients with inoperable lung cancer into a prospective study whose primary objectives were to determine first, the earliest time point when the maximum decrease in FDG uptake representing the maximum metabolic response (MMR) is attainable and second, the optimum cutoff value of MMR based on its predicted tumor control probability, sensitivity, and specificity. Of those patients, 61 completed the required 4 serial 18F-FDG PET examinations after therapy. Nineteen of 61 patients experienced local recurrence at the primary tumor and underwent analysis. The volumes of interest (VOI) on pretherapy FDG-PET were defined by use of an isocontour at ≥50% of maximum standard uptake value (SUVmax) (≥50% of SUVmax) with correction for heterogeneity. The VOI on posttherapy images were defined at ≥80% of SUVmax. The VOI of pretherapy and posttherapy 18F-FDG PET images were correlated for the extent of overlap. Results The size of VOI at pretherapy images was on average 25.7% (range, 8.8%-56.3%) of the pretherapy primary gross tumor volume (GTV), and their overlap fractions were 0.8 (95% confidence interval [CI]: 0.7-0.9), 0.63 (95% CI: 0.49-0.77), and 0.38 (95% CI: 0.19-0.57) of VOI of posttherapy FDG PET images at 10 days, 3 months, and 6 months, respectively. The residual uptake originated from the pretherapy VOI in 15 of 17 cases. Conclusions VOI defined by the SUVmax- ≥50% isocontour may be a biological target volume for escalated radiation dose. PMID:24725696

  6. Correlation of {sup 18}F-FDG Avid Volumes on Pre–Radiation Therapy and Post–Radiation Therapy FDG PET Scans in Recurrent Lung Cancer

    SciTech Connect

    Shusharina, Nadya Cho, Joseph; Sharp, Gregory C.; Choi, Noah C.

    2014-05-01

    Purpose: To investigate the spatial correlation between high uptake regions of 2-deoxy-2-[{sup 18}F]-fluoro-D-glucose positron emission tomography ({sup 18}F-FDG PET) before and after therapy in recurrent lung cancer. Methods and Materials: We enrolled 106 patients with inoperable lung cancer into a prospective study whose primary objectives were to determine first, the earliest time point when the maximum decrease in FDG uptake representing the maximum metabolic response (MMR) is attainable and second, the optimum cutoff value of MMR based on its predicted tumor control probability, sensitivity, and specificity. Of those patients, 61 completed the required 4 serial {sup 18}F-FDG PET examinations after therapy. Nineteen of 61 patients experienced local recurrence at the primary tumor and underwent analysis. The volumes of interest (VOI) on pretherapy FDG-PET were defined by use of an isocontour at ≥50% of maximum standard uptake value (SUV{sub max}) (≥50% of SUV{sub max}) with correction for heterogeneity. The VOI on posttherapy images were defined at ≥80% of SUV{sub max}. The VOI of pretherapy and posttherapy {sup 18}F-FDG PET images were correlated for the extent of overlap. Results: The size of VOI at pretherapy images was on average 25.7% (range, 8.8%-56.3%) of the pretherapy primary gross tumor volume (GTV), and their overlap fractions were 0.8 (95% confidence interval [CI]: 0.7-0.9), 0.63 (95% CI: 0.49-0.77), and 0.38 (95% CI: 0.19-0.57) of VOI of posttherapy FDG PET images at 10 days, 3 months, and 6 months, respectively. The residual uptake originated from the pretherapy VOI in 15 of 17 cases. Conclusions: VOI defined by the SUV{sub max}-≥50% isocontour may be a biological target volume for escalated radiation dose.

  7. Absolute-structure reports.

    PubMed

    Flack, Howard D

    2013-08-01

    All the 139 noncentrosymmetric crystal structures published in Acta Crystallographica Section C between January 2011 and November 2012 inclusive have been used as the basis of a detailed study of the reporting of absolute structure. These structure determinations cover a wide range of space groups, chemical composition and resonant-scattering contribution. Defining A and D as the average and difference of the intensities of Friedel opposites, their level of fit has been examined using 2AD and selected-D plots. It was found, regardless of the expected resonant-scattering contribution to Friedel opposites, that the Friedel-difference intensities are often dominated by random uncertainty and systematic error. An analysis of data collection strategy is provided. It is found that crystal-structure determinations resulting in a Flack parameter close to 0.5 may not necessarily be from crystals twinned by inversion. Friedifstat is shown to be a robust estimator of the resonant-scattering contribution to Friedel opposites, very little affected by the particular space group of a structure nor by the occupation of special positions. There is considerable confusion in the text of papers presenting achiral noncentrosymmetric crystal structures. Recommendations are provided for the optimal way of treating noncentrosymmetric crystal structures for which the experimenter has no interest in determining the absolute structure.

  8. A pharmacokinetic study to evaluate the absolute bioavailability of triamcinolone acetonide following inhalation administration.

    PubMed

    Argenti, D; Shah, B; Heald, D

    1999-07-01

    Triamcinolone acetonide is a glucocorticoid administered by oral inhalation in the management of asthma. With oral inhalation of glucocorticoids, systemic absorption can come from oropharyngeal, gastrointestinal, or airway deposition of the drug. The objectives of this study were to determine the absolute bioavailability of triamcinolone acetonide following inhalation administration and to delineate the airway contribution of triamcinolone acetonide absorption relative to the absolute bioavailability. All subjects received a 5-minute 400 mcg intravenous infusion of triamcinolone acetonide and a single 800 mcg dose of inhaled triamcinolone acetonide with and without oral charcoal administration in a randomized three-way crossover fashion. The oral charcoal allowed for isolating the pulmonary component of absorption by adsorbing the oropharyngeal and gastrointestinal deposited drug. The mean (+/- SD) absolute bioavailability value for inhaled triamcinolone acetonide was 25% (8.75%). Delineation of the airway contribution of triamcinolone acetonide absorption showed that 10.4% of an inhaled dose is absorbed as triamcinolone acetonide from the lungs. Mean (+/- SD) total body clearance was rapid at 0.57 (0.12) L/hr/kg. The mean (+/- SD) apparent volume of distribution following the intravenous dose was a low 1.96 (0.31) L/kg. No significant differences were noted in the apparent terminal elimination half-life of triamcinolone acetonide (approximately 2.4 hr) between treatments.

  9. SU-E-J-207: Assessing the Validity of 4D-CT Based Target Volumes and Free Breathing CBCT Localization in Lung Stereotactic Ablative Radiation Therapy (SABR)

    SciTech Connect

    Badkul, R; Pokhrel, D; Jiang, H; Park, J; Wang, F; Kumar, P

    2014-06-01

    Purpose: Four-dimensional-computed-tomography(4D-CT) imaging for target-volume delineation and cone-beam-tomography(CBCT) for treatment localization are widely utilized in lung-SABR.Aim of this study was to perform a quantitative-assessment and inter-comparison of Internal-targetvolumes( ITV) drawn on various phases of breathing-cycle 4D-CT-scans, Maximum-intensity-projection(MIP), average-intensity-projection(AIP)and static CT-scans of lung-motion-phantom to simulate lung-SABR patient geometry. We also analyzed and compared the ITVs drawn on freebreathing- CBCT. Materials and Methods: 4D-CT-scans were acquired on Philips big-bore 16slice CT and Bellows-respiratory monitoring-system using retrospective phase-binning method. Each respiratory cycle divided into 10-phases. Quasar-Phantom with lung-inserts and 3cm-diameter nylonball to simulate tumor and was placed on respiratory-motion-platform for 4D-CT and CBCT-acquisition. Amplitudes of motions: 0.5,1.0,2.0,3.0cm in superior-inferior direction with breathing-cycle time of 6,5,4,6sec, respectively used.4D-CTs with 10-phases(0%to90%)for each excursion-set and 3D-CT for static-phantom exported to iPlan treatment-planningsystem( TPS).Tumor-volumes delineated in all phases of 4D-CT, MIP,AIP,CBCT scans using fixed-HU-threshold(−500to1000)values automatically.For each 4D-dataset ITV obtained by unifying the tumorcontours on all phases.CBCT-ITV-volumes were drawn in Eclipse-TPS. Results: Mean volume of tumor contours for all phases compared with static 3D-CT were 0.62±0.08%, 1.67±0.26%, 4.77±0.54% and 9.27±1.23% for 0.5cm,1cm,2cm,3cm excursions respectively. Differences of mean Union-ITV with MIP-ITV were close(≤2.4%).Mean Union-ITV from expected-theoretical values differed from −4.9% to 3.8%.Union-ITV and MIP-ITV were closer within 2.3%. AIP-ITVs were underestimated from 14 to 32% compared to union-ITV for all motion datasets. Differences of −5.9% to −44% and −5% to 6.7% for CBCT-ITV from MIP-ITV and AIP

  10. Absolute Equilibrium Entropy

    NASA Technical Reports Server (NTRS)

    Shebalin, John V.

    1997-01-01

    The entropy associated with absolute equilibrium ensemble theories of ideal, homogeneous, fluid and magneto-fluid turbulence is discussed and the three-dimensional fluid case is examined in detail. A sigma-function is defined, whose minimum value with respect to global parameters is the entropy. A comparison is made between the use of global functions sigma and phase functions H (associated with the development of various H-theorems of ideal turbulence). It is shown that the two approaches are complimentary though conceptually different: H-theorems show that an isolated system tends to equilibrium while sigma-functions allow the demonstration that entropy never decreases when two previously isolated systems are combined. This provides a more complete picture of entropy in the statistical mechanics of ideal fluids.

  11. Absolute multilateration between spheres

    NASA Astrophysics Data System (ADS)

    Muelaner, Jody; Wadsworth, William; Azini, Maria; Mullineux, Glen; Hughes, Ben; Reichold, Armin

    2017-04-01

    Environmental effects typically limit the accuracy of large scale coordinate measurements in applications such as aircraft production and particle accelerator alignment. This paper presents an initial design for a novel measurement technique with analysis and simulation showing that that it could overcome the environmental limitations to provide a step change in large scale coordinate measurement accuracy. Referred to as absolute multilateration between spheres (AMS), it involves using absolute distance interferometry to directly measure the distances between pairs of plain steel spheres. A large portion of each sphere remains accessible as a reference datum, while the laser path can be shielded from environmental disturbances. As a single scale bar this can provide accurate scale information to be used for instrument verification or network measurement scaling. Since spheres can be simultaneously measured from multiple directions, it also allows highly accurate multilateration-based coordinate measurements to act as a large scale datum structure for localized measurements, or to be integrated within assembly tooling, coordinate measurement machines or robotic machinery. Analysis and simulation show that AMS can be self-aligned to achieve a theoretical combined standard uncertainty for the independent uncertainties of an individual 1 m scale bar of approximately 0.49 µm. It is also shown that combined with a 1 µm m‑1 standard uncertainty in the central reference system this could result in coordinate standard uncertainty magnitudes of 42 µm over a slender 1 m by 20 m network. This would be a sufficient step change in accuracy to enable next generation aerospace structures with natural laminar flow and part-to-part interchangeability.

  12. Several clinical interests regarding lung volume reduction surgery for severe emphysema: meta-analysis and systematic review of randomized controlled trials

    PubMed Central

    2011-01-01

    Objectives We aim to address several clinical interests regarding lung volume reduction surgery (LVRS) for severe emphysema using meta-analysis and systematic review of randomized controlled trials (RCTs). Methods Eight RCTs published from 1999 to 2010 were identified and synthesized to compare the efficacy and safety of LVRS vs conservative medical therapy. One RCT was obtained regarding comparison of median sternotomy (MS) and video-assisted thoracoscopic surgery (VATS). And three RCTs were available evaluating clinical efficacy of using bovine pericardium for buttressing, autologous fibrin sealant and BioGlue, respectively. Results Odds ratio (95%CI), expressed as the mortality of group A (the group underwent LVRS) versus group B (conservative medical therapies), was 5.16(2.84, 9.35) in 3 months, 3(0.94, 9.57) in 6 months, 1.05(0.82, 1.33) in 12 months, respectively. On the 3rd, 6th and 12th month, all lung function indices of group A were improved more significantly as compared with group B. PaO2 and PaCO2 on the 6th and 12th month showed the same trend. 6MWD of group A on the 6th month and 12th month were improved significantly than of group B, despite no difference on the 3rd month. Quality of life (QOL) of group A was better than of group B in 6 and 12 months. VATS is preferred to MS, due to the earlier recovery and lower cost. And autologous fibrin sealant and BioGlue seems to be the efficacious methods to reduce air leak following LVRS. Conclusions LVRS offers the more benefits regarding survival, lung function, gas exchange, exercise capacity and QOL, despite the higher mortality in initial three postoperative months. LVRS, with the optimization of surgical approach and material for reinforcement of the staple lines, should be recommended to patients suffering from severe heterogeneous emphysema. PMID:22074613

  13. Determination of Internal Target Volume From a Single Positron Emission Tomography/Computed Tomography Scan in Lung Cancer

    SciTech Connect

    Chang Guoping; Chang Tingting; Pan Tinsu; Clark, John W.; Mawlawi, Osama R.

    2012-05-01

    Purpose: The use of four-dimensional computed tomography (4D-CT) to determine the tumor internal target volume (ITV) is usually characterized by high patient radiation exposure. The objective of this study was to propose and evaluate an approach that relies on a single static positron emission tomography (PET)/CT scan to determine the ITV, thereby eliminating the need for 4D-CT and thus reduce patient radiation dose. Methods and Materials: The proposed approach is based on the concept that the observed PET image is the result of a joint convolution of an ideal PET image (free from motion and partial volume effect) with a motion-blurring kernel (MBK) and partial volume effect. In this regard, the MBK and tumor ITV are then estimated from the deconvolution of this joint model. To test this technique, phantom and patient studies were performed using different sphere/tumor sizes and motion trajectories. In all studies, a 4D-CT and a PET/CT image of the sphere/tumor were acquired. The ITV from the proposed technique was then compared to the maximum intensity projection (MIP) volume of the 4D-CT images. A Dice coefficient of the two volumes was calculated to represent the similarity between the two ITVs. Results: The average ITVs of the proposed technique were 97.2% {+-} 0.3% and 81.0% {+-} 16.7% similar to the MIP volume in the phantom and patient studies, respectively. The average dice coefficients were 0.87 {+-} 0.05 and 0.73 {+-} 0.16, respectively, for the two studies. Conclusion: Using the proposed approach, a single static PET/CT scan has the potential to replace a 4D-CT to determine the tumor ITV. This approach has the added advantage of reducing patient radiation exposure and determining the tumor MBK compared to 4D-CT/MIP-CT.

  14. [Radiotherapy for primary lung carcinoma].

    PubMed

    Giraud, P; Lacornerie, T; Mornex, F

    2016-09-01

    Indication, doses, technique of radiotherapy and concomitant chemotherapy, for primary lung carcinoma are presented. The recommendations for delineation of the target volumes and organs at risk are detailed.

  15. Factors affecting uncertainty in lung nodule volume estimation with CT: comparisons of findings from two estimation methods in a phantom study

    NASA Astrophysics Data System (ADS)

    Li, Qin; Gavrielides, Marios A.; Zeng, Rongping; Myers, Kyle J.; Sahiner, Berkman; Petrick, Nicholas

    2015-03-01

    collimation protocols, the measurements for both approaches were highly reproducible (RDC on the order of 15% or less). These findings are valuable for validating lung nodule volume as a quantitative imaging biomarker.

  16. Estimating Absolute Site Effects

    SciTech Connect

    Malagnini, L; Mayeda, K M; Akinci, A; Bragato, P L

    2004-07-15

    The authors use previously determined direct-wave attenuation functions as well as stable, coda-derived source excitation spectra to isolate the absolute S-wave site effect for the horizontal and vertical components of weak ground motion. They used selected stations in the seismic network of the eastern Alps, and find the following: (1) all ''hard rock'' sites exhibited deamplification phenomena due to absorption at frequencies ranging between 0.5 and 12 Hz (the available bandwidth), on both the horizontal and vertical components; (2) ''hard rock'' site transfer functions showed large variability at high-frequency; (3) vertical-motion site transfer functions show strong frequency-dependence, and (4) H/V spectral ratios do not reproduce the characteristics of the true horizontal site transfer functions; (5) traditional, relative site terms obtained by using reference ''rock sites'' can be misleading in inferring the behaviors of true site transfer functions, since most rock sites have non-flat responses due to shallow heterogeneities resulting from varying degrees of weathering. They also use their stable source spectra to estimate total radiated seismic energy and compare against previous results. they find that the earthquakes in this region exhibit non-constant dynamic stress drop scaling which gives further support for a fundamental difference in rupture dynamics between small and large earthquakes. To correct the vertical and horizontal S-wave spectra for attenuation, they used detailed regional attenuation functions derived by Malagnini et al. (2002) who determined frequency-dependent geometrical spreading and Q for the region. These corrections account for the gross path effects (i.e., all distance-dependent effects), although the source and site effects are still present in the distance-corrected spectra. The main goal of this study is to isolate the absolute site effect (as a function of frequency) by removing the source spectrum (moment-rate spectrum) from

  17. Comparison of internal target volumes defined on 3-dimensional, 4-dimensonal, and cone-beam CT images of non-small-cell lung cancer

    PubMed Central

    Li, Fengxiang; Li, Jianbin; Ma, Zhifang; Zhang, Yingjie; Xing, Jun; Qi, Huanpeng; Shang, Dongping

    2016-01-01

    Purpose The purpose of this study was to compare the positional and volumetric differences of internal target volumes defined on three-dimensional computed tomography (3DCT), four-dimensional CT (4DCT), and cone-beam CT (CBCT) images of non-small-cell lung cancer (NSCLC). Materials and methods Thirty-one patients with NSCLC sequentially underwent 3DCT and 4DCT simulation scans of the thorax during free breathing. The first CBCT was performed and registered to the planning CT using the bony anatomy registration during radiotherapy. The gross tumor volumes were contoured on the basis of 3DCT, maximum intensity projection (MIP) of 4DCT, and CBCT. CTV3D (clinical target volume), internal target volumes, ITVMIP and ITVCBCT, were defined with a 7 mm margin accounting for microscopic disease. ITV10 mm and ITV5 mm were defined on the basis of CTV3D: ITV10 mm with a 5 mm margin in left–right (LR), anterior–posterior (AP) directions and 10 mm in cranial–caudal (CC) direction; ITV5 mm with an isotropic internal margin (IM) of 5 mm. The differences in the position, size, Dice’s similarity coefficient (DSC) and inclusion relation of different volumes were evaluated. Results The median size ratios of ITV10 mm, ITV5 mm, and ITVMIP to ITVCBCT were 2.33, 1.88, and 1.03, respectively, for tumors in the upper lobe and 2.13, 1.76, and 1.1, respectively, for tumors in the middle-lower lobe. The median DSCs of ITV10 mm, ITV5 mm, ITVMIP, and ITVCBCT were 0.6, 0.66, and 0.83 for all patients. The median percentages of ITVCBCT not included in ITV10 mm, ITV5 mm, and ITVMIP were 0.1%, 1.63%, and 15.21%, respectively, while the median percentages of ITV10 mm, ITV5 mm, and ITVMIP not included in ITVCBCT were 57.08%, 48.89%, and 20.04%, respectively. Conclusion The use of the individual ITV derived from 4DCT merely based on bony registration in radiotherapy may result in a target miss. The ITVs derived from 3DCT with isotropic margins have a good coverage of the ITV from CBCT, but the

  18. SU-C-BRE-02: BED Vs. Local Control: Radiobiological Effect of Tumor Volume in Monte Carlo (MC) Lung SBRT Planning

    SciTech Connect

    Pokhrel, D; Badkul, R; Jiang, H; Estes, C; Park, J; Kumar, P; Wang, F

    2014-06-15

    Purpose: SBRT with hypofractionated dose schemata has emerged a compelling treatment modality for medically inoperable early stage lung cancer patients. It requires more accurate dose calculation and treatment delivery technique. This report presents the relationship between tumor control probability(TCP) and size-adjusted biological effective dose(sBED) of tumor volume for MC lung SBRT patients. Methods: Fifteen patients who were treated with MC-based lung SBRT to 50Gy in 5 fractions to PTVV100%=95% were studied. ITVs were delineated on MIP images of 4DCT-scans. PTVs diameter(ITV+5mm margins) ranged from 2.7–4.9cm (mean 3.7cm). Plans were generated using non-coplanar conformal arcs/beams using iPlan XVMC algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX with HD-MLCs and 6MVSRS(1000MU/min) mode, following RTOG-0813 dosimetric guidelines. To understand the known uncertainties of conventional heterogeneities-corrected/uncorrected pencil beam (PBhete/ PB-homo) algorithms, dose distributions were re-calculated with PBhete/ PB-homo using same beam configurations, MLCs and monitor units. Biologically effective dose(BED10) was computed using LQ-model with α/β=10Gy for meanPTV and meanITV. BED10-c*L, gave size-adjusted BED(sBED), where c=10Gy/cm and L=PTV diameter in centimeter. The TCP model was adopted from Ohri et al.(IJROBP, 2012): TCP = exp[sBEDTCD50]/ k /(1.0 + exp[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy; and more realistic MC-based TCP was computed for PTV(V99%). Results: Mean PTV PB-hete TCP value was 6% higher, but, mean PTV PB-homo TCP value was 4% lower compared to mean PTV MC TCP. Mean ITV PB-hete/PB-homo TCP values were comparable (within ±3.0%) to mean ITV MC TCP. The mean PTV(V99%)had BED10=90.9±3.7%(median=92.2%),sBED=54.1±8.2%(median=53.5%) corresponding to mean MC TCP value of 84.8±3.3%(median=84.9%) at 2- year local control. Conclusion: The TCP model which incorporates BED10 and tumor diameter indicates that radiobiological

  19. Optimizing Collimator Margins for Isotoxically Dose-Escalated Conformal Radiation Therapy of Non-Small Cell Lung Cancer

    SciTech Connect

    Warren, Samantha; Panettieri, Vanessa; Panakis, Niki; Bates, Nicholas; Lester, Jason F.; Jain, Pooja; Landau, David B.; Nahum, Alan E.; Mayles, W. Philip M.; Fenwick, John D.

    2014-04-01

    Purpose: Isotoxic dose escalation schedules such as IDEAL-CRT [isotoxic dose escalation and acceleration in lung cancer chemoradiation therapy] (ISRCTN12155469) individualize doses prescribed to lung tumors, generating a fixed modeled risk of radiation pneumonitis. Because the beam penumbra is broadened in lung, the choice of collimator margin is an important element of the optimization of isotoxic conformal radiation therapy for lung cancer. Methods and Materials: Twelve patients with stage I-III non-small cell lung cancer (NSCLC) were replanned retrospectively using a range of collimator margins. For each plan, the prescribed dose was calculated according to the IDEAL-CRT isotoxic prescription method, and the absolute dose (D{sub 99}) delivered to 99% of the planning target volume (PTV) was determined. Results: Reducing the multileaf collimator margin from the widely used 7 mm to a value of 2 mm produced gains of 2.1 to 15.6 Gy in absolute PTV D{sub 99}, with a mean gain ± 1 standard error of the mean of 6.2 ± 1.1 Gy (2-sided P<.001). Conclusions: For NSCLC patients treated with conformal radiation therapy and an isotoxic dose prescription, absolute doses in the PTV may be increased by using smaller collimator margins, reductions in relative coverage being offset by increases in prescribed dose.

  20. SU-E-T-289: Dose-Volume-Effect Relationships for Lung Cancer Patients Treated with SBRT On a Prospective Protocol

    SciTech Connect

    Mayyas, E; Brown, S; Liu, J; Kim, J; Sun, Z; Devpura, S; Ajlouni, M; Siddiqui, F; Movsas, B; Chetty, I

    2015-06-15

    Purpose: Stereotactic body radiotherapy (SBRT) is commonly used to treat early stage lung tumors. This study was designed to evaluate associations between dose, volume and clinical outcomes including analysis of both clinical toxicity scores and quality of life (QOL) data for non-small cell lung cancer patients treated with SBRT. Preliminary results are presented. Methods: Sixty-seven NSCLC patients, 46 primarily with early stage, and 21 with recurrent disease were treated with dose regimens consisting mainly of 12 Gy x 4 fractions, and 3 or 5 fractions at lower dose, for patients with recurrent disease (Table 1). Follow-up data is being collected at baseline, after treatment and at 3, 6, 12, 18 and 24 months post-treatment. Clinical follow-up data acquired to date was assessed using the Charlson Comorbidity Clinical and Toxicity Scoring forms. QOL data was evaluated using the EQ-5D, and FACT-TOI validated surveys. All outcomes surveys are collected within an “in-house” developed outcomes database. Results: The median follow-up was 3.5±0.8 months. Mean lung doses (MLD) were converted to BED-2 Gy using the linear-quadratic model with an alpha/beta=3.0. Average MLD was 3.7+3.1 Gy (range: 0.4–20.9 Gy). The percentages of patients with > grade 2 cough, dyspnea and fatigue were 13.3, 17.0, 6.3%, respectively. Preliminary analyses (at 3 months after SBRT) show a mild correlation between MLD > 2 Gy and > grade 2 cough (borderline significant) and dyspnea (significant, p<0.05). One patient was observed with a grade 3 cough. Given the short follow-up, tumor control is not yet assessable. Conclusion: The SBRT dose fractionation regimen of 12 Gy x 4 was well tolerated at early time points. Additional follow-up is required to assess the long-term clinical outcome efficacy and toxicity profiles of the dose regimen.

  1. Regional tidal lung strain in mechanically ventilated normal lungs.

    PubMed

    Paula, Luis Felipe; Wellman, Tyler J; Winkler, Tilo; Spieth, Peter M; Güldner, Andreas; Venegas, Jose G; Gama de Abreu, Marcelo; Carvalho, Alysson R; Vidal Melo, Marcos F

    2016-12-01

    Parenchymal strain is a key determinant of lung injury produced by mechanical ventilation. However, imaging estimates of volumetric tidal strain (ε = regional tidal volume/reference volume) present substantial conceptual differences in reference volume computation and consideration of tidally recruited lung. We compared current and new methods to estimate tidal volumetric strains with computed tomography, and quantified the effect of tidal volume (VT) and positive end-expiratory pressure (PEEP) on strain estimates. Eight supine pigs were ventilated with VT = 6 and 12 ml/kg and PEEP = 0, 6, and 12 cmH2O. End-expiratory and end-inspiratory scans were analyzed in eight regions of interest along the ventral-dorsal axis. Regional reference volumes were computed at end-expiration (with/without correction of regional VT for intratidal recruitment) and at resting lung volume (PEEP = 0) corrected for intratidal and PEEP-derived recruitment. All strain estimates demonstrated vertical heterogeneity with the largest tidal strains in middependent regions (P < 0.01). Maximal strains for distinct estimates occurred at different lung regions and were differently affected by VT-PEEP conditions. Values consistent with lung injury and inflammation were reached regionally, even when global measurements were below critical levels. Strains increased with VT and were larger in middependent than in nondependent lung regions. PEEP reduced tidal-strain estimates referenced to end-expiratory lung volumes, although it did not affect strains referenced to resting lung volume. These estimates of tidal strains in normal lungs point to middependent lung regions as those at risk for ventilator-induced lung injury. The different conditions and topography at which maximal strain estimates occur allow for testing the importance of each estimate for lung injury.

  2. Microgravity and the lung

    NASA Technical Reports Server (NTRS)

    West, John B.

    1991-01-01

    Results are presented from studies of the effect of microgravity on the lungs of rats flown on the Cosmos 2044 mission, and from relevant laboratory experiments. The effects of microgravity fall into five categories: topographical structure and function, the lung volumes and mechanics, the intrathoracic blood pressures and volumes, the pulmonary deposition of aerosol, and denitrogenaton during EVA. The ultrastructure of the left lungs of rats flown for 14 days on the Cosmos 2044 spacecraft and that of some tail-suspended rats disclosed presence of red blood cells in the alveolar spaces, indicating that pulmonary hemorrhage and pulmonary edema occurred in these rats. Possible causes for this phenomenon are discussed.

  3. Determining optimal clinical target volume margins on the basis of microscopic extracapsular extension of metastatic nodes in patients with non-small-cell lung cancer

    SciTech Connect

    Yuan Shuanghu; Meng Xue; Yu Jinming . E-mail: fishtigers@yahoo.com.cn; Mu Dianbin; Chao, K.S. Clifford; Zhang Jiandong; Zhong Weixia; Yu Yonghua; Wang Jialin; Sun Xindong; Yang Guoren; Wang Yongzheng

    2007-03-01

    Purpose: To determine the optimal clinical target volume (CTV) margins around the nodal gross tumor volume (GTV) in non-small-cell lung cancer (NSCLC) patients by assessing microscopic tumor extension beyond regional lymph node capsules. Methods and Materials: The incidence of nodal extracapsular extension (ECE) and relationship with nodal size were reviewed in 243 patients. Histologic sections of dissected regional lymph nodes up to 30 mm in size were examined to measure the extent of microscopic ECE. We determined the distribution of cases according to extent of ECE and the relationships between ECE extent and lymph node size, regional nodal disease extent, histologic type, and degree of differentiation. Results: The nodal ECE was seen in 41.6% of patients (101/243) and 33.4% of lymph nodes (214/640), and the incidence correlated to larger lymph node size positively. The extent of ECE was 0.7 mm in mean (range, 0-12.0 mm) and {<=}3 mm in 95% of the nodes. Positive correlations were found between extent of ECE and larger lymph node size ({>=}20 mm vs. 10-19 mm or <10 mm, p = 0.005), advanced nodal stage (N2 vs. N1, p = 0.046), and moderate or poor (vs. good or unknown) nodal differentiation (p = 0.002). ECE did not differ significantly by histologic type or nodal station. Conclusions: The incidence of ECE related to lymph node size, and ECE extent related to lymph node size, stage, and differentiation. It may be reasonable to recommend 3-mm CTV margins for pathologic lymph nodes <20 mm and more generous margins for lymph nodes {>=}20 mm.

  4. Radiobiological modeling of two stereotactic body radiotherapy schedules in patients with stage I peripheral non-small cell lung cancer

    PubMed Central

    Huang, Bao-tian; Lin, Zhu; Lin, Pei-xian; Lu, Jia-yang; Chen, Chuang-zhen

    2016-01-01

    This study aims to compare the radiobiological response of two stereotactic body radiotherapy (SBRT) schedules for patients with stage I peripheral non-small cell lung cancer (NSCLC) using radiobiological modeling methods. Volumetric modulated arc therapy (VMAT)-based SBRT plans were designed using two dose schedules of 1 × 34 Gy (34 Gy in 1 fraction) and 4 × 12 Gy (48 Gy in 4 fractions) for 19 patients diagnosed with primary stage I NSCLC. Dose to the gross target volume (GTV), planning target volume (PTV), lung and chest wall (CW) were converted to biologically equivalent dose in 2 Gy fraction (EQD2) for comparison. Five different radiobiological models were employed to predict the tumor control probability (TCP) value. Three additional models were utilized to estimate the normal tissue complication probability (NTCP) value for the lung and the modified equivalent uniform dose (mEUD) value to the CW. Our result indicates that the 1 × 34 Gy dose schedule provided a higher EQD2 dose to the tumor, lung and CW. Radiobiological modeling revealed that the TCP value for the tumor, NTCP value for the lung and mEUD value for the CW were 7.4% (in absolute value), 7.2% (in absolute value) and 71.8% (in relative value) higher on average, respectively, using the 1 × 34 Gy dose schedule. PMID:27203739

  5. CT image construction of a totally deflated lung using deformable model extrapolation

    SciTech Connect

    Sadeghi Naini, Ali; Pierce, Greg; Lee, Ting-Yim; and others

    2011-02-15

    Purpose: A novel technique is proposed to construct CT image of a totally deflated lung from a free-breathing 4D-CT image sequence acquired preoperatively. Such a constructed CT image is very useful in performing tumor ablative procedures such as lung brachytherapy. Tumor ablative procedures are frequently performed while the lung is totally deflated. Deflating the lung during such procedures renders preoperative images ineffective for targeting the tumor. Furthermore, the problem cannot be solved using intraoperative ultrasound (U.S.) images because U.S. images are very sensitive to small residual amount of air remaining in the deflated lung. One possible solution to address these issues is to register high quality preoperative CT images of the deflated lung with their corresponding low quality intraoperative U.S. images. However, given that such preoperative images correspond to an inflated lung, such CT images need to be processed to construct CT images pertaining to the lung's deflated state. Methods: To obtain the CT images of deflated lung, we present a novel image construction technique using extrapolated deformable registration to predict the deformation the lung undergoes during full deflation. The proposed construction technique involves estimating the lung's air volume in each preoperative image automatically in order to track the respiration phase of each 4D-CT image throughout a respiratory cycle; i.e., the technique does not need any external marker to form a respiratory signal in the process of curve fitting and extrapolation. The extrapolated deformation field is then applied on a preoperative reference image in order to construct the totally deflated lung's CT image. The technique was evaluated experimentally using ex vivo porcine lung. Results: The ex vivo lung experiments led to very encouraging results. In comparison with the CT image of the deflated lung we acquired for the purpose of validation, the constructed CT image was very similar. The

  6. Cryogenic, Absolute, High Pressure Sensor

    NASA Technical Reports Server (NTRS)

    Chapman, John J. (Inventor); Shams. Qamar A. (Inventor); Powers, William T. (Inventor)

    2001-01-01

    A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

  7. The Impact of Diffusion-Weighted MRI on the Definition of Gross Tumor Volume in Radiotherapy of Non-Small-Cell Lung Cancer

    PubMed Central

    Fleckenstein, Jochen; Jelden, Michael; Kremp, Stephanie; Jagoda, Philippe; Stroeder, Jonas; Khreish, Fadi; Ezziddin, Samer; Buecker, Arno; Rübe, Christian; Schneider, Guenther K.

    2016-01-01

    Objective The study was designed to evaluate diffusion-weighted magnetic resonance imaging (DWI) vs. PET-CT of the thorax in the determination of gross tumor volume (GTV) in radiotherapy planning of non-small-cell lung cancer (NSCLC). Materials and Methods Eligible patients with NSCLC who were supposed to receive definitive radio(chemo)therapy were prospectively recruited. For MRI, a respiratory gated T2-weighted sequence in axial orientation and non-gated DWI (b = 0, 800, 1,400 and apparent diffusion coefficient map [ADC]) were acquired on a 1.5 Tesla scanner. Primary tumors were delineated on FDG-PET/CT (stGTV) and DWI images (dwGTV). The definition of stGTV was based on the CT and visually adapted to the FDG-PET component if indicated (e.g., in atelectasis). For DWI, dwGTV was visually determined and adjusted for anatomical plausibility on T2w sequences. Beside a statistical comparison of stGTV and dwGTB, spatial agreement was determined with the “Hausdorff-Distance” (HD) and the “Dice Similarity Coefficient” (DSC). Results Fifteen patients (one patient with two synchronous NSCLC) were evaluated. For 16 primary tumors with UICC stages I (n = 4), II (n = 3), IIIA (n = 2) and IIIB (n = 7) mean values for dwGTV were significantly larger than those of stGTV (76.6 ± 84.5 ml vs. 66.6 ± 75.2 ml, p<0.01). The correlation of stGTV and dwGTV was highly significant (r = 0.995, p<0.001). Yet, some considerable volume deviations between these two methods were observed (median 27.5%, range 0.4–52.1%). An acceptable agreement between dwGTV and stGTV regarding the spatial extent of primary tumors was found (average HD: 2.25 ± 0.7 mm; DC 0.68 ± 0.09). Conclusion The overall level of agreement between PET-CT and MRI based GTV definition is acceptable. Tumor volumes may differ considerably in single cases. DWI-derived GTVs are significantly, yet modestly, larger than their PET-CT based counterparts. Prospective studies to assess the safety and efficacy of DWI

  8. Three-dimensional measurement of alveolar airspace volumes in normal and emphysematous lungs using micro-CT.

    PubMed

    Parameswaran, Harikrishnan; Bartolák-Suki, Erzsébet; Hamakawa, Hiroshi; Majumdar, Arnab; Allen, Philip G; Suki, Béla

    2009-08-01

    In pulmonary emphysema, the alveolar structure progressively breaks down via a three-dimensional (3D) process that leads to airspace enlargement. The characterization of such structural changes has, however, been based on measurements from two-dimensional (2D) tissue sections or estimates of 3D structure from 2D measurements. In this study, we developed a novel silver staining method for visualizing tissue structure in 3D using micro-computed tomographic (CT) imaging, which showed that at 30 cmH20 fixing pressure, the mean alveolar airspace volume increased from 0.12 nl in normal mice to 0.44 nl and 2.14 nl in emphysematous mice, respectively, at 7 and 14 days following elastase-induced injury. We also assessed tissue structure in 2D using laser scanning confocal microscopy. The mean of the equivalent diameters of the alveolar airspaces was lower in 2D compared with 3D, while its variance was higher in 2D than in 3D in all groups. However, statistical comparisons of alveolar airspace size from normal and emphysematous mice yielded similar results in 2D and 3D: compared with control, both the mean and variance of the equivalent diameters increased by 7 days after treatment. These indexes further increased from day 7 to day 14 following treatment. During the first 7 days following treatment, the relative change in SD increased at a much faster rate compared with the relative change in mean equivalent diameter. We conclude that quantifying heterogeneity in structure can provide new insight into the pathogenesis or progression of emphysema that is enhanced by improved sensitivity using 3D measurements.

  9. Lung Transplant

    MedlinePlus

    Lung transplant Overview By Mayo Clinic Staff A lung transplant is a surgical procedure to replace a diseased or ... lung, usually from a deceased donor. A lung transplant is reserved for people who have tried other ...

  10. Lung Emergencies

    MedlinePlus

    ... Emergencies Cardiac Emergencies Eye Emergencies Lung Emergencies Surgeries Lung Emergencies People with Marfan syndrome can be at ... should be considered an emergency. Symptoms of sudden lung collapse (pneumothorax) Symptoms of a sudden lung collapse ...

  11. High Dose-Per-Fraction Irradiation of Limited Lung Volumes Using an Image-Guided, Highly Focused Irradiator: Simulating Stereotactic Body Radiotherapy Regimens in a Small-Animal Model

    SciTech Connect

    Cho, Jaeho; Kodym, Reinhard; Seliounine, Serguei

    2010-07-01

    Purpose: To investigate the underlying biology associated with stereotactic body radiotherapy (SBRT), both in vivo models and image-guided, highly focal irradiation systems are necessary. Here, we describe such an irradiation system and use it to examine normal tissue toxicity in a small-animal model at lung volumes similar to those associated with human therapy. Methods and Materials: High-dose radiation was delivered to a small volume of the left lung of C3H/HeJCr mice using a small-animal stereotactic irradiator. The irradiator has a collimation mechanism to produce focal radiation beams, an imaging subsystem consisting of a fluorescent screen coupled to a charge-coupled device camera, and a manual positioning stage. Histopathologic examination and micro-CT were used to evaluate the radiation response. Results: Focal obliteration of the alveoli by fibrous connective tissue, hyperplasia of the bronchiolar epithelium, and presence of a small number of inflammatory cells are the main reactions to low-volume/high-dose irradiation of the mouse lung. The tissue response suggested a radiation dose threshold for early phase fibrosis lying between 40 and 100 Gy. The irradiation system satisfied our requirements of high-dose-rate, small beam diameter, and precise localization and verification. Conclusions: We have established an experimental model and image-guided animal irradiation system for the study of high dose per fraction irradiations such as those used with SBRT at volumes analogous to those used in human beings. It will also allow the targeting of specific anatomical structures of the thorax or ultimately, orthotopic tumors of the lung.

  12. Lung cancer

    SciTech Connect

    Aisner, J.

    1985-01-01

    This book contains 13 chapters. Some of the chapter titles are: The Pathology of Lung Cancer; Radiotherapy for Non-Small-Cell Cancer of the Lung; Chemotherapy for Non-Small-Cell Lung Cancer; Immunotherapy in the Management of Lung Cancer; Preoperative Staging and Surgery for Non-Small-Cell Lung Cancer; and Prognostic Factors in Lung Cancer.

  13. Cerium-144-induced lung gumors in two strains of mice

    SciTech Connect

    Hahn, F.F.; Griffith, W.C.

    1995-12-01

    A major problem in the extrapolation of radiation cancer risk factors from one species or population to another is the choice of the risk model to use, either absolute or relative. The purpose of this study was to compare absolute and relative risk models in predicting the lung-tumor risks between a low lung-tumor incidence strain of mice and a high-incidence strain of mice. The conclusion from this study is that absolute risk is more accurate than relative risk for predicting lung tumor risk from high to low lung-tumor incidence strains of mice.

  14. Database applicaton for absolute spectrophotometry

    NASA Astrophysics Data System (ADS)

    Bochkov, Valery V.; Shumko, Sergiy

    2002-12-01

    32-bit database application with multidocument interface for Windows has been developed to calculate absolute energy distributions of observed spectra. The original database contains wavelength calibrated observed spectra which had been already passed through apparatus reductions such as flatfielding, background and apparatus noise subtracting. Absolute energy distributions of observed spectra are defined in unique scale by means of registering them simultaneously with artificial intensity standard. Observations of sequence of spectrophotometric standards are used to define absolute energy of the artificial standard. Observations of spectrophotometric standards are used to define optical extinction in selected moments. FFT algorithm implemented in the application allows performing convolution (deconvolution) spectra with user-defined PSF. The object-oriented interface has been created using facilities of C++ libraries. Client/server model with Windows Socket functionality based on TCP/IP protocol is used to develop the application. It supports Dynamic Data Exchange conversation in server mode and uses Microsoft Exchange communication facilities.

  15. Clinical value of CT-based preoperative software assisted lung lobe volumetry for predicting postoperative pulmonary function after lung surgery

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Beyer, Florian; Hoffknecht, Petra; Dicken, Volker; Kuhnigk, Jan-Martin; Lange, Tobias; Thomas, Michael; Heindel, Walter

    2005-04-01

    This study was aimed to evaluate a morphology-based approach for prediction of postoperative forced expiratory volume in one second (FEV1) after lung resection from preoperative CT scans. Fifteen Patients with surgically treated (lobectomy or pneumonectomy) bronchogenic carcinoma were enrolled in the study. A preoperative chest CT and pulmonary function tests before and after surgery were performed. CT scans were analyzed by prototype software: automated segmentation and volumetry of lung lobes was performed with minimal user interaction. Determined volumes of different lung lobes were used to predict postoperative FEV1 as percentage of the preoperative values. Predicted FEV1 values were compared to the observed postoperative values as standard of reference. Patients underwent lobectomy in twelve cases (6 upper lobes; 1 middle lobe; 5 lower lobes; 6 right side; 6 left side) and pneumonectomy in three cases. Automated calculation of predicted postoperative lung function was successful in all cases. Predicted FEV1 ranged from 54% to 95% (mean 75% +/- 11%) of the preoperative values. Two cases with obviously erroneous LFT were excluded from analysis. Mean error of predicted FEV1 was 20 +/- 160 ml, indicating absence of systematic error; mean absolute error was 7.4 +/- 3.3% respective 137 +/- 77 ml/s. The 200 ml reproducibility criterion for FEV1 was met in 11 of 13 cases (85%). In conclusion, software-assisted prediction of postoperative lung function yielded a clinically acceptable agreement with the observed postoperative values. This method might add useful information for evaluation of functional operability of patients with lung cancer.

  16. Dose-volume modeling of the risk of postoperative pulmonary complications among esophageal cancer patients treated with concurrent chemoradiotherapy followed by surgery

    SciTech Connect

    Tucker, Susan L. . E-mail: sltucker@mdanderson.org; Liu, H. Helen; Wang, Shulian; Wei Xiong; Liao Zhongxing; Komaki, Ritsuko; Cox, James D.; Mohan, Radhe

    2006-11-01

    Purpose: The aim of this study was to investigate the effect of radiation dose distribution in the lung on the risk of postoperative pulmonary complications among esophageal cancer patients. Methods and Materials: We analyzed data from 110 patients with esophageal cancer treated with concurrent chemoradiotherapy followed by surgery at our institution from 1998 to 2003. The endpoint for analysis was postsurgical pneumonia or acute respiratory distress syndrome. Dose-volume histograms (DVHs) and dose-mass histograms (DMHs) for the whole lung were used to fit normal-tissue complication probability (NTCP) models, and the quality of fits were compared using bootstrap analysis. Results: Normal-tissue complication probability modeling identified that the risk of postoperative pulmonary complications was most significantly associated with small absolute volumes of lung spared from doses {>=}5 Gy (VS5), that is, exposed to doses <5 Gy. However, bootstrap analysis found no significant difference between the quality of this model and fits based on other dosimetric parameters, including mean lung dose, effective dose, and relative volume of lung receiving {>=}5 Gy, probably because of correlations among these factors. The choice of DVH vs. DMH or the use of fractionation correction did not significantly affect the results of the NTCP modeling. The parameter values estimated for the Lyman NTCP model were as follows (with 95% confidence intervals in parentheses): n = 1.85 (0.04, {infinity}), m = 0.55 (0.22, 1.02), and D {sub 5} = 17.5 Gy (9.4 Gy, 102 Gy). Conclusions: In this cohort of esophageal cancer patients, several dosimetric parameters including mean lung dose, effective dose, and absolute volume of lung receiving <5 Gy provided similar descriptions of the risk of postoperative pulmonary complications as a function of Radiation dose distribution in the lung.

  17. Absolute classification with unsupervised clustering

    NASA Technical Reports Server (NTRS)

    Jeon, Byeungwoo; Landgrebe, D. A.

    1992-01-01

    An absolute classification algorithm is proposed in which the class definition through training samples or otherwise is required only for a particular class of interest. The absolute classification is considered as a problem of unsupervised clustering when one cluster is known initially. The definitions and statistics of the other classes are automatically developed through the weighted unsupervised clustering procedure, which is developed to keep the cluster corresponding to the class of interest from losing its identity as the class of interest. Once all the classes are developed, a conventional relative classifier such as the maximum-likelihood classifier is used in the classification.

  18. High Radiation Dose May Reduce the Negative Effect of Large Gross Tumor Volume in Patients With Medically Inoperable Early-Stage Non-Small Cell Lung Cancer

    SciTech Connect

    Zhao Lujun; West, Brady T.; Hayman, James A.; Lyons, Susan; Cease, Kemp; Kong, F.-M. . E-mail: Fengkong@med.umich.edu

    2007-05-01

    Purpose: To determine whether the effect of radiation dose varies with gross tumor volume (GTV) in patients with stage I/II non-small cell lung cancer (NSCLC). Methods and Materials: Included in the study were 114 consecutive patients with medically inoperable stage I/II NSCLC treated with three-dimensional conformal radiotherapy between 1992 and 2004. The median biologic equivalent dose (BED) was 79.2 Gy (range, 58.2-124.5 Gy). The median GTV was 51.8 cm{sup 3} (range, 2.1-727.8 cm{sup 3}). The primary endpoint was overall survival (OS). Kaplan-Meier estimation and Cox regression models were used for survival analyses. Results: Multivariate analysis showed that there was a significant interaction between radiation dose and GTV (p < 0.001). In patients with BED {<=}79.2 Gy (n = 68), the OS medians for patients with GTV >51.8 cm{sup 3} and {<=}51.8 cm{sup 3} were 18.2 and 23.9 months, respectively (p 0.015). If BED was >79.2 Gy (n = 46), no significant difference was found between GTV groups (p = 0.681). For patients with GTV >51.8 cm{sup 3} (n = 45), the OS medians in those with BED >79.2 Gy and {<=}79.2 Gy were 30.4 and 18.2 months, respectively (p < 0.001). If GTV was {<=}51.8 cm{sup 3} (n = 45), the difference was no longer significant (p = 0.577). Conclusion: High-dose radiation is more important for patients with larger tumors and may be effective in reducing the adverse outcome associated with large GTV. Further prospective studies are needed to confirm this finding.

  19. SU-E-T-513: Investigating Dose of Internal Target Volume After Correcting for Tissue Heterogeneity in SBRT Lung Plans with Homogeneity Calculation

    SciTech Connect

    Qi, P; Zhuang, T; Magnelli, A; Djemil, T; Shang, Q; Balik, S; Andrews, M; Stephans, K; Videtic, G; Xia, P

    2015-06-15

    Purpose It was recommended to use the prescription of 54 Gy/3 with heterogeneity corrections for previously established dose scheme of 60 Gy/3 with homogeneity calculation. This study is to investigate dose coverage for the internal target volume (ITV) with and without heterogeneity correction. Methods Thirty patients who received stereotactic body radiotherapy (SBRT) to a dose of 60 Gy in 3 fractions with homogeneous planning for early stage non-small-cell lung cancer (NSCLC) were selected. ITV was created either from 4DCT scans or a fusion of multi-phase respiratory scans. Planning target volume (PTV) was a 5 mm expansion of the ITV. For this study, we recalculated homogeneous clinical plans using heterogeneity corrections with monitor units set as clinically delivered. All plans were calculated with 3 mm dose grids and collapsed cone convolution algorithm. To account for uncertainties from tumor delineation and image-guided radiotherapy, a structure ITV2mm was created by expanding ITV with 2 mm margins. Dose coverage to the PTV, ITV and ITV2mm were compared with a student paired t-test. Results With heterogeneity corrections, the PTV V60Gy decreased by 10.1% ± 18.4% (p<0.01) while the maximum dose to the PTV increased by 3.7 ± 4.3% (p<0.01). With and without corrections, D99% was 65.8 ± 4.0 Gy and 66.7 ± 4.8 Gy (p=0.15) for the ITV, and 63.9 ± 3.4 Gy and 62.9 ± 4.6 Gy for the ITV2mm (p=0.22), respectively. The mean dose to the ITV and ITV2mm increased 3.6% ± 4.7% (p<0.01) and 2.3% ± 5.2% (p=0.01) with heterogeneity corrections. Conclusion After heterogeneity correction, the peripheral coverage of the PTV decreased to approximately 54 Gy, but D99% of the ITV and ITV2mm was unchanged and the mean dose to the ITV and ITV2mm was increased. Clinical implication of these results requires more investigation.

  20. Absolute transition probabilities of phosphorus.

    NASA Technical Reports Server (NTRS)

    Miller, M. H.; Roig, R. A.; Bengtson, R. D.

    1971-01-01

    Use of a gas-driven shock tube to measure the absolute strengths of 21 P I lines and 126 P II lines (from 3300 to 6900 A). Accuracy for prominent, isolated neutral and ionic lines is estimated to be 28 to 40% and 18 to 30%, respectively. The data and the corresponding theoretical predictions are examined for conformity with the sum rules.-

  1. Relativistic Absolutism in Moral Education.

    ERIC Educational Resources Information Center

    Vogt, W. Paul

    1982-01-01

    Discusses Emile Durkheim's "Moral Education: A Study in the Theory and Application of the Sociology of Education," which holds that morally healthy societies may vary in culture and organization but must possess absolute rules of moral behavior. Compares this moral theory with current theory and practice of American educators. (MJL)

  2. Absolute Standards for Climate Measurements

    NASA Astrophysics Data System (ADS)

    Leckey, J.

    2016-10-01

    In a world of changing climate, political uncertainty, and ever-changing budgets, the benefit of measurements traceable to SI standards increases by the day. To truly resolve climate change trends on a decadal time scale, on-orbit measurements need to be referenced to something that is both absolute and unchanging. One such mission is the Climate Absolute Radiance and Refractivity Observatory (CLARREO) that will measure a variety of climate variables with an unprecedented accuracy to definitively quantify climate change. In the CLARREO mission, we will utilize phase change cells in which a material is melted to calibrate the temperature of a blackbody that can then be observed by a spectrometer. A material's melting point is an unchanging physical constant that, through a series of transfers, can ultimately calibrate a spectrometer on an absolute scale. CLARREO consists of two primary instruments: an infrared (IR) spectrometer and a reflected solar (RS) spectrometer. The mission will contain orbiting radiometers with sufficient accuracy to calibrate other space-based instrumentation and thus transferring the absolute traceability. The status of various mission options will be presented.

  3. Volume or Position Changes of Primary Lung Tumor During (Chemo-)Radiotherapy Cannot Be Used as a Surrogate for Mediastinal Lymph Node Changes: The Case for Optimal Mediastinal Lymph Node Imaging During Radiotherapy

    SciTech Connect

    Elmpt, Wouter van; Ollers, Michel; Herwijnen, Henrieke van; Holder, Linda den; Vercoulen, Lindsay; Wouters, Monique; Lambin, Philippe; De Ruysscher, Dirk

    2011-01-01

    Purpose: Primary lung tumors can be visualized mostly with cone beam computed tomography (CT), whereas visualization is much more difficult for mediastinal lymph nodes (LN). If the volumetric and positional changes of the primary tumor could be used as a surrogate for the LN, this would facilitate image-guided radiotherapy. The purpose of this study was to investigate the relationship between the positional and volumetric changes in primary tumors and the involved LN during (chemo)radiotherapy treatment of non-small-cell lung cancer patients. Methods and Materials: [{sup 18}F]fluorodeoxyglucose positron emission tomography/computed tomography imaging was performed before radiotherapy and in the second week of treatment in 35 patients. Gross tumor volumes (GTV) of the primary tumor (GTVprim) and of the involved LN (GTVlymph) were delineated. Changes in position and volume of GTVprim with respect to GTVlymph and the bony anatomy were compared. Results: In individual cases, large displacements up to 1.6 cm and volume changes of 50% of the primary tumor may occur that are not correlated to the changes in involved LN. The volume of GTVprim reduced, on average, by 5.7% {+-} 19.0% and was not correlated with the small increase of 1.4% {+-} 18.2% in involved LN volume. Compared to bony anatomy, displacement of the primary tumor was statistically correlated to the involved LN displacement. Conclusions: Volume and position changes of the primary tumor are not always predictive for LN changes. This suggests that for characterization of involved LN, repeated state-of-the-art mediastinal imaging during radiotherapy may be necessary.

  4. Measured and modelled absolute gravity in Greenland

    NASA Astrophysics Data System (ADS)

    Nielsen, E.; Forsberg, R.; Strykowski, G.

    2012-12-01

    Present day changes in the ice volume in glaciated areas like Greenland will change the load on the Earth and to this change the lithosphere will respond elastically. The Earth also responds to changes in the ice volume over a millennial time scale. This response is due to the viscous properties of the mantle and is known as Glaical Isostatic Adjustment (GIA). Both signals are present in GPS and absolute gravity (AG) measurements and they will give an uncertainty in mass balance estimates calculated from these data types. It is possible to separate the two signals if both gravity and Global Positioning System (GPS) time series are available. DTU Space acquired an A10 absolute gravimeter in 2008. One purpose of this instrument is to establish AG time series in Greenland and the first measurements were conducted in 2009. Since then are 18 different Greenland GPS Network (GNET) stations visited and six of these are visited more then once. The gravity signal consists of three signals; the elastic signal, the viscous signal and the direct attraction from the ice masses. All of these signals can be modelled using various techniques. The viscous signal is modelled by solving the Sea Level Equation with an appropriate ice history and Earth model. The free code SELEN is used for this. The elastic signal is modelled as a convolution of the elastic Greens function for gravity and a model of present day ice mass changes. The direct attraction is the same as the Newtonian attraction and is calculated as this. Here we will present the preliminary results of the AG measurements in Greenland. We will also present modelled estimates of the direct attraction, the elastic and the viscous signals.

  5. Automatic Approach for Lung Segmentation with Juxta-Pleural Nodules from Thoracic CT Based on Contour Tracing and Correction.

    PubMed

    Wang, Jinke; Guo, Haoyan

    2016-01-01

    This paper presents a fully automatic framework for lung segmentation, in which juxta-pleural nodule problem is brought into strong focus. The proposed scheme consists of three phases: skin boundary detection, rough segmentation of lung contour, and pulmonary parenchyma refinement. Firstly, chest skin boundary is extracted through image aligning, morphology operation, and connective region analysis. Secondly, diagonal-based border tracing is implemented for lung contour segmentation, with maximum cost path algorithm used for separating the left and right lungs. Finally, by arc-based border smoothing and concave-based border correction, the refined pulmonary parenchyma is obtained. The proposed scheme is evaluated on 45 volumes of chest scans, with volume difference (VD) 11.15 ± 69.63 cm(3), volume overlap error (VOE) 3.5057 ± 1.3719%, average surface distance (ASD) 0.7917 ± 0.2741 mm, root mean square distance (RMSD) 1.6957 ± 0.6568 mm, maximum symmetric absolute surface distance (MSD) 21.3430 ± 8.1743 mm, and average time-cost 2 seconds per image. The preliminary results on accuracy and complexity prove that our scheme is a promising tool for lung segmentation with juxta-pleural nodules.

  6. Automatic Approach for Lung Segmentation with Juxta-Pleural Nodules from Thoracic CT Based on Contour Tracing and Correction

    PubMed Central

    2016-01-01

    This paper presents a fully automatic framework for lung segmentation, in which juxta-pleural nodule problem is brought into strong focus. The proposed scheme consists of three phases: skin boundary detection, rough segmentation of lung contour, and pulmonary parenchyma refinement. Firstly, chest skin boundary is extracted through image aligning, morphology operation, and connective region analysis. Secondly, diagonal-based border tracing is implemented for lung contour segmentation, with maximum cost path algorithm used for separating the left and right lungs. Finally, by arc-based border smoothing and concave-based border correction, the refined pulmonary parenchyma is obtained. The proposed scheme is evaluated on 45 volumes of chest scans, with volume difference (VD) 11.15 ± 69.63 cm3, volume overlap error (VOE) 3.5057 ± 1.3719%, average surface distance (ASD) 0.7917 ± 0.2741 mm, root mean square distance (RMSD) 1.6957 ± 0.6568 mm, maximum symmetric absolute surface distance (MSD) 21.3430 ± 8.1743 mm, and average time-cost 2 seconds per image. The preliminary results on accuracy and complexity prove that our scheme is a promising tool for lung segmentation with juxta-pleural nodules. PMID:27974907

  7. Estimation of Lung Ventilation

    NASA Astrophysics Data System (ADS)

    Ding, Kai; Cao, Kunlin; Du, Kaifang; Amelon, Ryan; Christensen, Gary E.; Raghavan, Madhavan; Reinhardt, Joseph M.

    Since the primary function of the lung is gas exchange, ventilation can be interpreted as an index of lung function in addition to perfusion. Injury and disease processes can alter lung function on a global and/or a local level. MDCT can be used to acquire multiple static breath-hold CT images of the lung taken at different lung volumes, or with proper respiratory control, 4DCT images of the lung reconstructed at different respiratory phases. Image registration can be applied to this data to estimate a deformation field that transforms the lung from one volume configuration to the other. This deformation field can be analyzed to estimate local lung tissue expansion, calculate voxel-by-voxel intensity change, and make biomechanical measurements. The physiologic significance of the registration-based measures of respiratory function can be established by comparing to more conventional measurements, such as nuclear medicine or contrast wash-in/wash-out studies with CT or MR. An important emerging application of these methods is the detection of pulmonary function change in subjects undergoing radiation therapy (RT) for lung cancer. During RT, treatment is commonly limited to sub-therapeutic doses due to unintended toxicity to normal lung tissue. Measurement of pulmonary function may be useful as a planning tool during RT planning, may be useful for tracking the progression of toxicity to nearby normal tissue during RT, and can be used to evaluate the effectiveness of a treatment post-therapy. This chapter reviews the basic measures to estimate regional ventilation from image registration of CT images, the comparison of them to the existing golden standard and the application in radiation therapy.

  8. Mini-implants and miniplates generate sub-absolute and absolute anchorage.

    PubMed

    Consolaro, Alberto

    2014-01-01

    The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and resorption that happen to meet the functional demands. The endosteum and the periosteum are the effectors responsible for stimulating adaptive osteocytes in the inner and outer surfaces. Changes in shape, volume and position of the jaws as a result of skeletal correction of the maxilla and mandible require anchorage to allow bone remodeling to redefine morphology, esthetics and function as a result of spatial deformation conducted by orthodontic appliances. Examining the degree of changes in shape, volume and structural relationship of areas where mini-implants and miniplates are placed allows us to classify mini-implants as devices of subabsolute anchorage and miniplates as devices of absolute anchorage.

  9. Lung Transplantation

    MedlinePlus

    ... are used to treat people who have severe COPD Cystic fibrosis Idiopathic pulmonary fibrosis Alpha-1 antitrypsin deficiency Pulmonary hypertension Complications of lung transplantation include rejection of the transplanted lung and infection. NIH: National Heart, Lung, and Blood Institute

  10. Lung transplant

    MedlinePlus

    ... in the arteries of the lungs ( pulmonary hypertension ) Sarcoidosis Lung transplant may not be done for people ... Chronic Cystic fibrosis Idiopathic pulmonary fibrosis Lung disease Sarcoidosis Review Date 4/13/2015 Updated by: Dale ...

  11. Lung disease

    MedlinePlus

    ... they can't breathe deeply. Pulmonary fibrosis and sarcoidosis are examples of lung tissue disease. Lung circulation ... tuberculosis Pulmonary veno-occlusive disease Rheumatoid lung disease Sarcoidosis Simple pulmonary eosinophilia Patient Instructions Chronic obstructive pulmonary ...

  12. Absolute calibration of optical flats

    DOEpatents

    Sommargren, Gary E.

    2005-04-05

    The invention uses the phase shifting diffraction interferometer (PSDI) to provide a true point-by-point measurement of absolute flatness over the surface of optical flats. Beams exiting the fiber optics in a PSDI have perfect spherical wavefronts. The measurement beam is reflected from the optical flat and passed through an auxiliary optic to then be combined with the reference beam on a CCD. The combined beams include phase errors due to both the optic under test and the auxiliary optic. Standard phase extraction algorithms are used to calculate this combined phase error. The optical flat is then removed from the system and the measurement fiber is moved to recombine the two beams. The newly combined beams include only the phase errors due to the auxiliary optic. When the second phase measurement is subtracted from the first phase measurement, the absolute phase error of the optical flat is obtained.

  13. The Absolute Spectrum Polarimeter (ASP)

    NASA Technical Reports Server (NTRS)

    Kogut, A. J.

    2010-01-01

    The Absolute Spectrum Polarimeter (ASP) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from 30 GHz to 5 THz. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much greater than 1O(raised to the power of { -3}) and Compton distortion y < 10 (raised to the power of{-6}). We describe the ASP instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

  14. Optomechanics for absolute rotation detection

    NASA Astrophysics Data System (ADS)

    Davuluri, Sankar

    2016-07-01

    In this article, we present an application of optomechanical cavity for the absolute rotation detection. The optomechanical cavity is arranged in a Michelson interferometer in such a way that the classical centrifugal force due to rotation changes the length of the optomechanical cavity. The change in the cavity length induces a shift in the frequency of the cavity mode. The phase shift corresponding to the frequency shift in the cavity mode is measured at the interferometer output to estimate the angular velocity of absolute rotation. We derived an analytic expression to estimate the minimum detectable rotation rate in our scheme for a given optomechanical cavity. Temperature dependence of the rotation detection sensitivity is studied.

  15. Reduction in Tumor Volume by Cone Beam Computed Tomography Predicts Overall Survival in Non-Small Cell Lung Cancer Treated With Chemoradiation Therapy

    SciTech Connect

    Jabbour, Salma K.; Kim, Sinae; Haider, Syed A.; Xu, Xiaoting; Wu, Alson; Surakanti, Sujani; Aisner, Joseph; Langenfeld, John; Yue, Ning J.; Haffty, Bruce G.; Zou, Wei

    2015-07-01

    Purpose: We sought to evaluate whether tumor response using cone beam computed tomography (CBCT) performed as part of the routine care during chemoradiation therapy (CRT) could forecast the outcome of unresectable, locally advanced, non-small cell lung cancer (NSCLC). Methods and Materials: We manually delineated primary tumor volumes (TV) of patients with NSCLC who were treated with radical CRT on days 1, 8, 15, 22, 29, 36, and 43 on CBCTs obtained as part of the standard radiation treatment course. Percentage reductions in TV were calculated and then correlated to survival and pattern of recurrence using Cox proportional hazard models. Clinical information including histologic subtype was also considered in the study of such associations. Results: We evaluated 38 patients with a median follow-up time of 23.4 months. The median TV reduction was 39.3% (range, 7.3%-69.3%) from day 1 (D1) to day 43 (D43) CBCTs. Overall survival was associated with TV reduction from D1 to D43 (hazard ratio [HR] 0.557, 95% CI 0.39-0.79, P=.0009). For every 10% decrease in TV from D1 to D43, the risk of death decreased by 44.3%. For patients whose TV decreased ≥39.3 or <39.3%, log-rank test demonstrated a separation in survival (P=.02), with median survivals of 31 months versus 10 months, respectively. Neither local recurrence (HR 0.791, 95% CI 0.51-1.23, P=.29), nor distant recurrence (HR 0.78, 95% CI 0.57-1.08, P=.137) correlated with TV decrease from D1 to D43. Histologic subtype showed no impact on our findings. Conclusions: TV reduction as determined by CBCT during CRT as part of routine care predicts post-CRT survival. Such knowledge may justify intensification of RT or application of additional therapies. Assessment of genomic characteristics of these tumors may permit a better understanding of behavior or prediction of therapeutic outcomes.

  16. Morphometric examination of native lungs in human lung allograft recipients.

    PubMed

    Wiebe, B M; Burton, C M; Milman, N; Iversen, M; Andersen, C B

    2006-11-01

    The aim of the study was to estimate the degree of lung damage in patients with alpha(1)-antitrypsin (alpha1AT) deficiency, chronic obstructive pulmonary disease (COPD), and cystic fibrosis (CF) at the time of lung transplantation. Using unbiased stereological methods, lung-, bronchial- and vessel-volume, capillary length, and alveolar surface area and densities were estimated in recipient lungs from 21 consecutive patients with pre-transplant diagnoses including COPD (n=7), alpha1AT deficiency (n=6) and CF (n=8). Six unused adult donor lungs served as controls. Information relating to patient demography and pre-transplant lung function was obtained by retrospective chart review. Disease groups differed significantly with respect to demographics and pre-transplant lung function. Total lung volume was similar in all groups. Bronchial volume was significantly larger in CF patients compared to the control group (p<0.0001) and to the other two diagnostic groups: alpha1AT deficiency (p=0.0001) and COPD (p<0.0001). Alveolar surface density and capillary length density were significantly lower in patients with alpha1AT deficiency and COPD compared to controls (p<0.0001, respectively) and to patients with CF (p<0.0002, respectively). There were no correlations between clinical lung function and morphometric measurements. We conclude that unbiased microscopic stereological morphometry is an evolving science with the potential to elucidate pulmonary disease pathogenesis.

  17. A Phase II Comparative Study of Gross Tumor Volume Definition With or Without PET/CT Fusion in Dosimetric Planning for Non-Small-Cell Lung Cancer (NSCLC): Primary Analysis of Radiation Therapy Oncology Group (RTOG) 0515

    SciTech Connect

    Bradley, Jeffrey; Bae, Kyounghwa; Choi, Noah; Forster, Ken; Siegel, Barry A.; Brunetti, Jacqueline; Purdy, James; Faria, Sergio; Vu, Toni; Thorstad, Wade; Choy, Hak

    2012-01-01

    Background: Radiation Therapy Oncology Group (RTOG) 0515 is a Phase II prospective trial designed to quantify the impact of positron emission tomography (PET)/computed tomography (CT) compared with CT alone on radiation treatment plans (RTPs) and to determine the rate of elective nodal failure for PET/CT-derived volumes. Methods: Each enrolled patient underwent definitive radiation therapy for non-small-cell lung cancer ({>=}60 Gy) and had two RTP datasets generated: gross tumor volume (GTV) derived with CT alone and with PET/CT. Patients received treatment using the PET/CT-derived plan. The primary end point, the impact of PET/CT fusion on treatment plans was measured by differences of the following variables for each patient: GTV, number of involved nodes, nodal station, mean lung dose (MLD), volume of lung exceeding 20 Gy (V20), and mean esophageal dose (MED). Regional failure rate was a secondary end point. The nonparametric Wilcoxon matched-pairs signed-ranks test was used with Bonferroni adjustment for an overall significance level of 0.05. Results: RTOG 0515 accrued 52 patients, 47 of whom are evaluable. The follow-up time for all patients is 12.9 months (2.7-22.2). Tumor staging was as follows: II = 6%; IIIA = 40%; and IIIB = 54%. The GTV was statistically significantly smaller for PET/CT-derived volumes (98.7 vs. 86.2 mL; p < 0.0001). MLDs for PET/CT plans were slightly lower (19 vs. 17.8 Gy; p = 0.06). There was no significant difference in the number of involved nodes (2.1 vs. 2.4), V20 (32% vs. 30.8%), or MED (28.7 vs. 27.1 Gy). Nodal contours were altered by PET/CT for 51% of patients. One patient (2%) has developed an elective nodal failure. Conclusions: PET/CT-derived tumor volumes were smaller than those derived by CT alone. PET/CT changed nodal GTV contours in 51% of patients. The elective nodal failure rate for GTVs derived by PET/CT is quite low, supporting the RTOG standard of limiting the target volume to the primary tumor and involved nodes.

  18. Absolute calibration of optical tweezers

    SciTech Connect

    Viana, N.B.; Mazolli, A.; Maia Neto, P.A.; Nussenzveig, H.M.; Rocha, M.S.; Mesquita, O.N.

    2006-03-27

    As a step toward absolute calibration of optical tweezers, a first-principles theory of trapping forces with no adjustable parameters, corrected for spherical aberration, is experimentally tested. Employing two very different setups, we find generally very good agreement for the transverse trap stiffness as a function of microsphere radius for a broad range of radii, including the values employed in practice, and at different sample chamber depths. The domain of validity of the WKB ('geometrical optics') approximation to the theory is verified. Theoretical predictions for the trapping threshold, peak position, depth variation, multiple equilibria, and 'jump' effects are also confirmed.

  19. Automated lung segmentation of low resolution CT scans of rats

    NASA Astrophysics Data System (ADS)

    Rizzo, Benjamin M.; Haworth, Steven T.; Clough, Anne V.

    2014-03-01

    Dual modality micro-CT and SPECT imaging can play an important role in preclinical studies designed to investigate mechanisms, progression, and therapies for acute lung injury in rats. SPECT imaging involves examining the uptake of radiopharmaceuticals within the lung, with the hypothesis that uptake is sensitive to the health or disease status of the lung tissue. Methods of quantifying lung uptake and comparison of right and left lung uptake generally begin with identifying and segmenting the lung region within the 3D reconstructed SPECT volume. However, identification of the lung boundaries and the fissure between the left and right lung is not always possible from the SPECT images directly since the radiopharmaceutical may be taken up by other surrounding tissues. Thus, our SPECT protocol begins with a fast CT scan, the lung boundaries are identified from the CT volume, and the CT region is coregistered with the SPECT volume to obtain the SPECT lung region. Segmenting rat lungs within the CT volume is particularly challenging due to the relatively low resolution of the images and the rat's unique anatomy. Thus, we have developed an automated segmentation algorithm for low resolution micro-CT scans that utilizes depth maps to detect fissures on the surface of the lung volume. The fissure's surface location is in turn used to interpolate the fissure throughout the lung volume. Results indicate that the segmentation method results in left and right lung regions consistent with rat lung anatomy.

  20. Patterns of Local-Regional Failure in Completely Resected Stage IIIA(N2) Non-Small Cell Lung Cancer Cases: Implications for Postoperative Radiation Therapy Clinical Target Volume Design

    SciTech Connect

    Feng, Wen; Fu, Xiao-Long; Cai, Xu-Wei; Yang, Huan-Jun; Wu, Kai-Liang; Fan, Min; Xiang, Jia-Qing; Zhang, Ya-Wei; Chen, Hai-Quan

    2014-04-01

    Purpose: To analyze patterns of local-regional failure (LRF) for completely resected stage IIIA(N2) non-small cell lung cancer (NSCLC) patients treated in our hospital and to propose a clinical target volume (CTV) for postoperative radiation therapy (PORT) in these patients. Methods and Materials: From 2005 to 2011, consecutive patients with pT1-3N2 NSCLC who underwent complete resection in our hospital but who did not receive PORT were identified. The patterns of first LRF were assessed and evaluated as to whether these areas would be encompassed by our proposed PORT CTV. Results: With a median follow-up of 24 months, 173 of 250 patients (69.2%) experienced disease recurrence. Of the 54 patients with LRF as the first event, 48 (89%) had recurrence within the proposed PORT CTV, and 6 (11%) had failures occurring both within and outside the proposed CTV (all of which occurred in patients with right-lung cancer). Ninety-three percent of failure sites (104 of 112) would have been contained within the proposed PORT CTV. For left-sided lung cancer, the most common lymph node station failure site was 4R, followed by 7, 4L, 6, 10L, and 5. For right-sided lung cancer, the most common site was station 2R, followed by 10R, 4R, and 7. Conclusions: LRF following complete surgery was an important and potentially preventable pattern of failure in stage IIIA(N2) patients. Ipsilateral superior mediastinal recurrences dominated for right-sided tumors, whereas left-sided tumors frequently involved the bilateral superior mediastinum. Most of the LRF sites would have been covered by the proposed PORT CTV. A prospective investigation of patterns of failure after PORT (following our proposed CTV delineation guideline) is presently underway and will be reported in a separate analysis.

  1. Time-Adjusted Internal Target Volume: A Novel Approach Focusing on Heterogeneity of Tumor Motion Based on 4-Dimensional Computed Tomography Imaging for Radiation Therapy Planning of Lung Cancer

    SciTech Connect

    Nishibuchi, Ikuno; Kimura, Tomoki; Nakashima, Takeo; Ochi, Yusuke; Takahashi, Ippei; Doi, Yoshiko; Kenjo, Masahiro; Kaneyasu, Yuko; Ozawa, Syuichi; Murakami, Yuji; Wadasaki, Koichi; Nagata, Yasushi

    2014-08-01

    Purpose: To consider nonuniform tumor motion within the internal target volume (ITV) by defining time-adjusted ITV (TTV), a volume designed to include heterogeneity of tumor existence on the basis of 4-dimensional computed tomography (4D-CT). Methods and Materials: We evaluated 30 lung cancer patients. Breath-hold CT (BH-CT) and free-breathing 4D-CT scans were acquired for each patient. The tumors were manually delineated using a lung CT window setting (window, 1600 HU; level, −300 HU). Tumor in BH-CT images was defined as gross tumor volume (GTV), and the sum of tumors in 4D-CT images was defined as ITV-4D. The TTV images were generated from the 4D-CT datasets, and the tumor existence probability within ITV-4D was calculated. We calculated the TTV{sub 80} value, which is the percentage of the volume with a tumor existence probability that exceeded 80% on ITV-4D. Several factors that affected the TTV{sub 80} value, such as the ITV-4D/GTV ratio or tumor centroid deviation, were evaluated. Results: Time-adjusted ITV images were acquired for all patients, and tumor respiratory motion heterogeneity was visualized. The median (range) ITV-4D/GTV ratio and median tumor centroid deviation were 1.6 (1.0-4.1) and 6.3 mm (0.1-30.3 mm), respectively. The median TTV{sub 80} value was 43.3% (2.9-98.7%). Strong correlations were observed between the TTV{sub 80} value and the ITV-4D/GTV ratio (R=−0.71) and tumor centroid deviation (R=−0.72). The TTV images revealed the tumor motion pattern features within ITV. Conclusions: The TTV images reflected nonuniform tumor motion, and they revealed the tumor motion pattern features, suggesting that the TTV concept may facilitate various aspects of radiation therapy planning of lung cancer while incorporating respiratory motion in the future.

  2. Cosmology with negative absolute temperatures

    NASA Astrophysics Data System (ADS)

    Vieira, J. P. P.; Byrnes, Christian T.; Lewis, Antony

    2016-08-01

    Negative absolute temperatures (NAT) are an exotic thermodynamical consequence of quantum physics which has been known since the 1950's (having been achieved in the lab on a number of occasions). Recently, the work of Braun et al. [1] has rekindled interest in negative temperatures and hinted at a possibility of using NAT systems in the lab as dark energy analogues. This paper goes one step further, looking into the cosmological consequences of the existence of a NAT component in the Universe. NAT-dominated expanding Universes experience a borderline phantom expansion (w < -1) with no Big Rip, and their contracting counterparts are forced to bounce after the energy density becomes sufficiently large. Both scenarios might be used to solve horizon and flatness problems analogously to standard inflation and bouncing cosmologies. We discuss the difficulties in obtaining and ending a NAT-dominated epoch, and possible ways of obtaining density perturbations with an acceptable spectrum.

  3. A treatment-planning comparison of three beam arrangement strategies for stereotactic body radiation therapy for centrally located lung tumors using volumetric-modulated arc therapy

    PubMed Central

    Ishii, Kentaro; Okada, Wataru; Ogino, Ryo; Kubo, Kazuki; Kishimoto, Shun; Nakahara, Ryuta; Kawamorita, Ryu; Ishii, Yoshie; Tada, Takuhito; Nakajima, Toshifumi

    2016-01-01

    The purpose of this study was to determine appropriate beam arrangement for volumetric-modulated arc therapy (VMAT)-based stereotactic body radiation therapy (SBRT) in the treatment of patients with centrally located lung tumors. Fifteen consecutive patients with centrally located lung tumors treated at our institution were enrolled. For each patient, three VMAT plans were generated using two coplanar partial arcs (CP VMAT), two non-coplanar partial arcs (NCP VMAT), and one coplanar full arc (Full VMAT). All plans were designed to deliver 70 Gy in 10 fractions. Target coverage and sparing of organs at risk (OARs) were compared across techniques. PTV coverage was almost identical for all approaches. The whole lung V10Gy was significantly lower with CP VMAT plans than with NCP VMAT plans, whereas no significant differences in the mean lung dose, V5Gy, V20Gy or V40Gy were observed. Full VMAT increased mean contralateral lung V5Gy by 12.57% and 9.15% when compared with NCP VMAT and CP VMAT, respectively. Although NCP VMAT plans best achieved the dose–volume constraints for mediastinal OARs, the absolute differences in dose were small when compared with CP VMAT. These results suggest that partial-arc VMAT may be preferable to minimize unnecessary exposure to the contralateral lung, and use of NCP VMAT should be considered when the dose–volume constraints are not achieved by CP VMAT. PMID:26951076

  4. Lung Injury After One-Lung Ventilation: A Review of the Pathophysiologic Mechanisms Affecting the Ventilated and the Collapsed Lung.

    PubMed

    Lohser, Jens; Slinger, Peter

    2015-08-01

    Lung injury is the leading cause of death after thoracic surgery. Initially recognized after pneumonectomy, it has since been described after any period of 1-lung ventilation (OLV), even in the absence of lung resection. Overhydration and high tidal volumes were thought to be responsible at various points; however, it is now recognized that the pathophysiology is more complex and multifactorial. All causative mechanisms known to trigger ventilator-induced lung injury have been described in the OLV setting. The ventilated lung is exposed to high strain secondary to large, nonphysiologic tidal volumes and loss of the normal functional residual capacity. In addition, the ventilated lung experiences oxidative stress, as well as capillary shear stress because of hyperperfusion. Surgical manipulation and/or resection of the collapsed lung may induce lung injury. Re-expansion of the collapsed lung at the conclusion of OLV invariably induces duration-dependent, ischemia-reperfusion injury. Inflammatory cytokines are released in response to localized injury and may promote local and contralateral lung injury. Protective ventilation and volatile anesthesia lessen the degree of injury; however, increases in biochemical and histologic markers of lung injury appear unavoidable. The endothelial glycocalyx may represent a common pathway for lung injury creation during OLV, because it is damaged by most of the recognized lung injurious mechanisms. Experimental therapies to stabilize the endothelial glycocalyx may afford the ability to reduce lung injury in the future. In the interim, protective ventilation with tidal volumes of 4 to 5 mL/kg predicted body weight, positive end-expiratory pressure of 5 to 10 cm H2O, and routine lung recruitment should be used during OLV in an attempt to minimize harmful lung stress and strain. Additional strategies to reduce lung injury include routine volatile anesthesia and efforts to minimize OLV duration and hyperoxia.

  5. SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

    SciTech Connect

    Hou, Y; Aileen, C; Kozono, D; Killoran, J; Wagar, M; Lee, S; Hacker, F; Aerts, H; Lewis, J; Mak, R

    2015-06-15

    Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after the same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye

  6. 21 CFR 868.2450 - Lung water monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung...

  7. 21 CFR 868.2450 - Lung water monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung...

  8. 21 CFR 868.2450 - Lung water monitor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung...

  9. 21 CFR 868.2450 - Lung water monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung...

  10. Mild loss of lung aeration augments stretch in healthy lung regions.

    PubMed

    Cereda, Maurizio; Xin, Yi; Hamedani, Hooman; Clapp, Justin; Kadlecek, Stephen; Meeder, Natalie; Zeng, Johnathan; Profka, Harrilla; Kavanagh, Brian P; Rizi, Rahim R

    2016-02-15

    Inspiratory stretch by mechanical ventilation worsens lung injury. However, it is not clear whether and how the ventilator damages lungs in the absence of preexisting injury. We hypothesized that subtle loss of lung aeration during general anesthesia regionally augments ventilation and distension of ventilated air spaces. In eight supine anesthetized and intubated rats, hyperpolarized gas MRI was performed after a recruitment maneuver following 1 h of volume-controlled ventilation with zero positive end-expiratory pressure (ZEEP), FiO2 0.5, and tidal volume 10 ml/kg, and after a second recruitment maneuver. Regional fractional ventilation (FV), apparent diffusion coefficient (ADC) of (3)He (a measurement of ventilated peripheral air space dimensions), and gas volume were measured in lung quadrants of ventral and dorsal regions of the lungs. In six additional rats, computed tomography (CT) images were obtained at each time point. Ventilation with ZEEP decreased total lung gas volume and increased both FV and ADC in all studied regions. Increases in FV were more evident in the dorsal slices. In each lung quadrant, higher ADC was predicted by lower gas volume and by increased mean values (and heterogeneity) of FV distribution. CT scans documented 10% loss of whole-lung aeration and increased density in the dorsal lung, but no macroscopic atelectasis. Loss of pulmonary gas at ZEEP increased fractional ventilation and inspiratory dimensions of ventilated peripheral air spaces. Such regional changes could help explain a propensity for mechanical ventilation to contribute to lung injury in previously uninjured lungs.

  11. Stereology of the lung.

    PubMed

    Schneider, Jan Philipp; Ochs, Matthias

    2013-01-01

    Many scientific projects require a quantitative assessment of organ, tissue and cell (ultra)structure. Such quantitative (morphometric) data are essential to make statistically valid comparisons between experimental groups. The structures of interest are measured at different microscopic levels. However, measurements in microscopy pose two problems: 1) Only a small fraction of the whole biological system can be analyzed (sampling problem). 2) The analysis is performed on nearly two-dimensional (physical, optical or virtual) sections through the object although the aim is to obtain biologically meaningful three-dimensional data (3D vs 2D problem). These problems are solved by the application of unbiased sampling and measurement tools known as stereology. This chapter gives a brief introduction to the theory and practical application of stereology, using the lung as an example. Stereological tools needed to quantify volume, number and surface area are introduced and examples are given how to estimate total lung volume, volume of lung parenchyma, alveolar surface area and number of alveolar epithelial type II cells per lung.

  12. Continued artificial selection for running endurance in rats is associated with improved lung function.

    PubMed

    Kirkton, Scott D; Howlett, Richard A; Gonzalez, Norberto C; Giuliano, Patrick G; Britton, Steven L; Koch, Lauren G; Wagner, Harrieth E; Wagner, Peter D

    2009-06-01

    Previous studies found that selection for endurance running in untrained rats produced distinct high (HCR) and low (LCR) capacity runners. Furthermore, despite weighing 14% less, 7th generation HCR rats achieved the same absolute maximal oxygen consumption (Vo(2max)) as LCR due to muscle adaptations that improved oxygen extraction and use. However, there were no differences in cardiopulmonary function after seven generations of selection. If selection for increased endurance capacity continued, we hypothesized that due to the serial nature of oxygen delivery enhanced cardiopulmonary function would be required. In the present study, generation 15 rats selected for high and low endurance running capacity showed differences in pulmonary function. HCR, now 25% lighter than LCR, reached a 12% higher absolute Vo(2max) than LCR, P < 0.05 (49% higher Vo(2max)/kg). Despite the 25% difference in body size, both lung volume (at 20 cmH(2)O airway pressure) and exercise diffusing capacity were similar in HCR and LCR. Lung volume of LCR lay on published mammalian allometrical relationships while that of HCR lay above that line. Alveolar ventilation at Vo(2max) was 30% higher, P < 0.05 (78% higher, per kg), arterial Pco(2) was 4.5 mmHg (17%) lower, P < 0.05, while total pulmonary vascular resistance was (insignificantly) 5% lower (30% lower, per kg) in HCR. The smaller mass of HCR animals was due mostly to a smaller body frame rather than to a lower fat mass. These findings show that by generation 15, lung size in smaller HCR rats is not reduced in concert with their smaller body size, but has remained similar to that of LCR, supporting the hypothesis that continued selection for increased endurance capacity requires relatively larger lungs, supporting greater ventilation, gas exchange, and pulmonary vascular conductance.

  13. {sup 18}F-FDG PET Definition of Gross Tumor Volume for Radiotherapy of Lung Cancer: Is the Tumor Uptake Value-Based Approach Appropriate for Lymph Node Delineation?

    SciTech Connect

    Rodriguez, Nuria; Sanz, Xavier; Trampal, Carlos; Foro, Palmira; Reig, Anna; Lacruz, Marti; Membrive, Ismael; Lozano, Joan; Quera, Jaime; Algara, Manuel

    2010-11-01

    Purpose: Positron emission tomography (PET) with the glucose analogue [18F] fluoro-2-deoxy-D-glucose ({sup 18}F-FDG-PET) has been used in radiation treatment planning for non-small-cell carcinoma. To date, lymph nodes have been contoured according to the uptake of the tumor. This prospective study was performed to evaluate if nodal volume delineates according to FDG uptake within the primary tumor (PET-GTVnt) is suitable for nodal target volume delineation or if individualized nodal FDG uptake measure (PET-GTVnn) is necessary to better nodal target definition. Methods and Materials: Forty cases, who underwent a diagnostic {sup 18}F-FDG PET/computed tomography (CT) scan, were included. Two PET-based GTVs for each lymph node were contoured and compared. First, we used an isocontour of 40% of the maximum tumor uptake (PET-GTVnt). Second, an isocontour of 40% of the maximum uptake of each node (PET-GTVnn) was employed. To avoid interobserver variability, this was carried out by the same radiation oncologist. Afterwards, the difference between both lymph node volumes was plotted against the ratio of the maximum uptakes (I{sub n}/I{sub t}) in a linear regression analysis. Results: Compared with CT-based lymph node volume (CT-GTVn), the intraclass correlation coefficient of PET-GTVnn was higher than the coefficient of PET-GTVnt (p < 0.001). All cases could be divided into four groups: undetected (17.5%), detected but overestimated (10%), detected but underestimated (35%), and correctly detected (37.5%). Conclusions: If a method of automatic delineation shall be applied, this method must be applied to every lesion separately. However, to facilitate the delineation in daily practice, when I{sub n}/I{sub t} is {<=}25%, lymph nodes could be delineated in accordance with tumor uptake, keeping an absolute difference in radii <5 mm.

  14. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    SciTech Connect

    Goldstein, Jeffrey D.; Lawrence, Yaacov R.; Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader; Segel, Michael J.; Peled, Nir; Symon, Zvi

    2015-10-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.

  15. Lunge performance and its determinants.

    PubMed

    Cronin, John; McNair, Peter J; Marshall, Robert N

    2003-01-01

    For activities such as squash, badminton and fencing, the ability to quickly complete a lunge and return to the start or move off in another direction is critical for success. Determining which strength qualities are important predictors of lunge performance was the focus of this study. Thirty-one male athletes performed: (1) a unilateral maximal squat (one-repetition maximum, 1-RM) and unilateral jump squat (50% 1-RM) on an instrumented supine squat machine, and (2) a forward lunge while attached to a linear transducer. We performed stepwise multiple regression analysis with lunge performance as the dependent variable and various strength, flexibility and anthropometric measures as the independent variables. From the many strength and power measures calculated, time to peak force was the best single predictor of lunge performance, which accounted for 55% of the explained variance. The best three-variable model for predicting lunge performance accounted for 76-85% of the explained variance. The models differed, however, according to whether lunge performance was expressed relative to body mass (time to peak force, mean power and relative strength = 76%) or taken as an absolute value (time to peak force, leg length and flexibility = 85%). We conclude that one to two trials were reliable for strength diagnosis and that one strength measure cannot accurately explain functional performance because other factors, such as body mass, flexibility and leg length, have diverse effects on the statistical models.

  16. Lung Organogenesis

    PubMed Central

    Warburton, David; El-Hashash, Ahmed; Carraro, Gianni; Tiozzo, Caterina; Sala, Frederic; Rogers, Orquidea; De Langhe, Stijn; Kemp, Paul J.; Riccardi, Daniela; Torday, John; Bellusci, Saverio; Shi, Wei; Lubkin, Sharon R; Jesudason, Edwin

    2011-01-01

    Developmental lung biology is a field that has the potential for significant human impact: lung disease at the extremes of age continues to cause major morbidity and mortality worldwide. Understanding how the lung develops holds the promise that investigators can use this knowledge to aid lung repair and regeneration. In the decade since the “molecular embryology” of the lung was first comprehensively reviewed, new challenges have emerged—and it is on these that we focus the current review. Firstly, there is a critical need to understand the progenitor cell biology of the lung in order to exploit the potential of stem cells for the treatment of lung disease. Secondly, the current familiar descriptions of lung morphogenesis governed by growth and transcription factors need to be elaborated upon with the reinclusion and reconsideration of other factors, such as mechanics, in lung growth. Thirdly, efforts to parse the finer detail of lung bud signaling may need to be combined with broader consideration of overarching mechanisms that may be therapeutically easier to target: in this arena, we advance the proposal that looking at the lung in general (and branching in particular) in terms of clocks may yield unexpected benefits. PMID:20691848

  17. Lung-protective ventilation in neonatology.

    PubMed

    van Kaam, Anton

    2011-01-01

    Ventilator-induced lung injury (VILI) is considered an important risk factor in the development of bronchopulmonary dysplasia (BPD) and is primarily caused by overdistension (volutrauma) and repetitive opening and collapse (atelectrauma) of terminal lung units. Lung-protective ventilation should therefore aim to reduce tidal volumes, and recruit and stabilize atelectatic lung units (open lung ventilation strategy). This review will summarize the available evidence on lung-protective ventilation in neonatology, discussing both high-frequency ventilation (HFV) and positive pressure ventilation (PPV). It shows that HFV does not appear to have a clear benefit over PPV, although most studies failed to apply a true open lung ventilation strategy during HFV. The evidence on the optimal tidal volume, positive end-expiratory pressure and the role for lung recruitment during lung-protective PPV is extremely limited. Volume-targeted ventilation seems to be a promising mode in terms of lung protection, but more studies are needed. Due to the lack of convincing evidence, lung-protective ventilation and modes seem to be implemented in daily clinical practice at a slow pace.

  18. Stereotactic Body Radiotherapy for Primary Lung Cancer at a Dose of 50 Gy Total in Five Fractions to the Periphery of the Planning Target Volume Calculated Using a Superposition Algorithm

    SciTech Connect

    Takeda, Atsuya; Sanuki, Naoko; Kunieda, Etsuo Ohashi, Toshio; Oku, Yohei; Takeda, Toshiaki; Shigematsu, Naoyuki; Kubo, Atsushi

    2009-02-01

    Purpose: To retrospectively analyze the clinical outcomes of stereotactic body radiotherapy (SBRT) for patients with Stages 1A and 1B non-small-cell lung cancer. Methods and Materials: We reviewed the records of patients with non-small-cell lung cancer treated with curative intent between Dec 2001 and May 2007. All patients had histopathologically or cytologically confirmed disease, increased levels of tumor markers, and/or positive findings on fluorodeoxyglucose positron emission tomography. Staging studies identified their disease as Stage 1A or 1B. Performance status was 2 or less according to World Health Organization guidelines in all cases. The prescribed dose of 50 Gy total in five fractions, calculated by using a superposition algorithm, was defined for the periphery of the planning target volume. Results: One hundred twenty-one patients underwent SBRT during the study period, and 63 were eligible for this analysis. Thirty-eight patients had Stage 1A (T1N0M0) and 25 had Stage 1B (T2N0M0). Forty-nine patients were not appropriate candidates for surgery because of chronic pulmonary disease. Median follow-up of these 49 patients was 31 months (range, 10-72 months). The 3-year local control, disease-free, and overall survival rates in patients with Stages 1A and 1B were 93% and 96% (p = 0.86), 76% and 77% (p = 0.83), and 90% and 63% (p = 0.09), respectively. No acute toxicity was observed. Grade 2 or higher radiation pneumonitis was experienced by 3 patients, and 1 of them had fatal bacterial pneumonia. Conclusions: The SBRT at 50 Gy total in five fractions to the periphery of the planning target volume calculated by using a superposition algorithm is feasible. High local control rates were achieved for both T2 and T1 tumors.

  19. Linking lung function and inflammatory responses in ventilator-induced lung injury.

    PubMed

    Cannizzaro, Vincenzo; Hantos, Zoltan; Sly, Peter D; Zosky, Graeme R

    2011-01-01

    Despite decades of research, the mechanisms of ventilator-induced lung injury are poorly understood. We used strain-dependent responses to mechanical ventilation in mice to identify associations between mechanical and inflammatory responses in the lung. BALB/c, C57BL/6, and 129/Sv mice were ventilated using a protective [low tidal volume and moderate positive end-expiratory pressure (PEEP) and recruitment maneuvers] or injurious (high tidal volume and zero PEEP) ventilation strategy. Lung mechanics and lung volume were monitored using the forced oscillation technique and plethysmography, respectively. Inflammation was assessed by measuring numbers of inflammatory cells, cytokine (IL-6, IL-1β, and TNF-α) levels, and protein content of the BAL. Principal components factor analysis was used to identify independent associations between lung function and inflammation. Mechanical and inflammatory responses in the lung were dependent on ventilation strategy and mouse strain. Three factors were identified linking 1) pulmonary edema, protein leak, and macrophages, 2) atelectasis, IL-6, and TNF-α, and 3) IL-1β and neutrophils, which were independent of responses in lung mechanics. This approach has allowed us to identify specific inflammatory responses that are independently associated with overstretch of the lung parenchyma and loss of lung volume. These data provide critical insight into the mechanical responses in the lung that drive local inflammation in ventilator-induced lung injury and the basis for future mechanistic studies in this field.

  20. Sensation of inspired volumes and pressures in professional wind instrument players.

    PubMed

    Smith, J; Kreisman, H; Colacone, A; Fox, J; Wolkove, N

    1990-06-01

    Previous studies have failed to show consistent differences in pulmonary function between wind instrument musicians and normal controls. In this study, respiratory sensation was assessed in 13 professional wind instrument players and 13 age-matched controls. Psychophysical techniques were used to assess magnitude estimation and reproduction of lung volumes and inspiratory pressures. The exponent for volume magnitude estimation was not different in musicians and controls (1.17 +/- 0.11 vs. 1.16 +/- 0.11), but volume reproduction was more accurate in musicians. The mean exponent for pressure magnitude estimation was 1.34 +/- 0.14 and 1.06 +/- 0.09 (P = 0.057) in musicians and controls, respectively. There was no difference between groups for absolute or constant error for pressure reproduction. Professional wind instrument players appear to have some inherent or acquired differences in respiratory perception and ventilatory neuromuscular control compared with other normal subjects.

  1. Absolute optical metrology : nanometers to kilometers

    NASA Technical Reports Server (NTRS)

    Dubovitsky, Serge; Lay, O. P.; Peters, R. D.; Liebe, C. C.

    2005-01-01

    We provide and overview of the developments in the field of high-accuracy absolute optical metrology with emphasis on space-based applications. Specific work on the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor is described along with novel applications of the sensor.

  2. ON A SUFFICIENT CONDITION FOR ABSOLUTE CONTINUITY.

    DTIC Science & Technology

    The formulation of a condition which yields absolute continuity when combined with continuity and bounded variation is the problem considered in the...Briefly, the formulation is achieved through a discussion which develops a proof by contradiction of a sufficiently theorem for absolute continuity which uses in its hypothesis the condition of continuity and bounded variation .

  3. Introducing the Mean Absolute Deviation "Effect" Size

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  4. Monolithically integrated absolute frequency comb laser system

    SciTech Connect

    Wanke, Michael C.

    2016-07-12

    Rather than down-convert optical frequencies, a QCL laser system directly generates a THz frequency comb in a compact monolithically integrated chip that can be locked to an absolute frequency without the need of a frequency-comb synthesizer. The monolithic, absolute frequency comb can provide a THz frequency reference and tool for high-resolution broad band spectroscopy.

  5. Absolute instability of the Gaussian wake profile

    NASA Technical Reports Server (NTRS)

    Hultgren, Lennart S.; Aggarwal, Arun K.

    1987-01-01

    Linear parallel-flow stability theory has been used to investigate the effect of viscosity on the local absolute instability of a family of wake profiles with a Gaussian velocity distribution. The type of local instability, i.e., convective or absolute, is determined by the location of a branch-point singularity with zero group velocity of the complex dispersion relation for the instability waves. The effects of viscosity were found to be weak for values of the wake Reynolds number, based on the center-line velocity defect and the wake half-width, larger than about 400. Absolute instability occurs only for sufficiently large values of the center-line wake defect. The critical value of this parameter increases with decreasing wake Reynolds number, thereby indicating a shrinking region of absolute instability with decreasing wake Reynolds number. If backflow is not allowed, absolute instability does not occur for wake Reynolds numbers smaller than about 38.

  6. Registration of clinical volumes to beams-eye-view images for real-time tracking

    SciTech Connect

    Bryant, Jonathan H.; Rottmann, Joerg; Lewis, John H.; Mishra, Pankaj; Berbeco, Ross I.; Keall, Paul J.

    2014-12-15

    Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

  7. Registration of clinical volumes to beams-eye-view images for real-time tracking

    PubMed Central

    Bryant, Jonathan H.; Rottmann, Joerg; Lewis, John H.; Mishra, Pankaj; Keall, Paul J.; Berbeco, Ross I.

    2014-01-01

    Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations. PMID:25471950

  8. Moving Back to the Future: Use of Organ Care System Lung for Lobectomy Before Lobar Lung Transplantation.

    PubMed

    Sabashnikov, Anton; Zeriouh, Mohamed; Mohite, Prashant N; Patil, Nikhil P; García-Sáez, Diana; Schmack, Bastian; Soresi, Simona; Dohmen, Pascal M; Popov, Aron-Frederik; Weymann, Alexander; Simon, André R; De Robertis, Fabio

    2016-07-13

    BACKGROUND Lung transplantation remains the gold standard treatment for patients with end-stage lung disease. Lobar lung transplantation allows for transplantation of size-mismatch donor lungs in small recipients; however, donor lung volume reduction represents a challenging surgical technique. In this paper we present our initial experience with bilateral lobectomy in donor lungs before lobar lung transplantation using normothermic perfusion on the Organ Care System (OCS) Lung. MATERIAL AND METHODS Specifics of the surgical technique for donor lung instrumentation on the OCS, lobar dissection on the OCS, and right and left donor lobectomies are presented in detail. RESULTS Potential advantages of the use of the OCS for lobectomy for lobar lung transplantation are described in this section. Donor lung volume reduction utilizing OCS appeared to be easier and safer compared to the conventional cold storage technique, due to continuous perfusion of the lungs with blood and well-distended vessels that offer the feel of live lobectomy. Moreover, the OCS represents a platform for donor organ assessment and optimization of its function before transplantation. CONCLUSIONS Donor lung volume reduction was safe and feasible utilizing the OCS, which could be a useful tool for volume reduction in cases of size mismatch. Further research is needed to evaluate early and long-term results after lobar lung transplantation using the OCS in clinical studies.

  9. Absolute quantitation of protein posttranslational modification isoform.

    PubMed

    Yang, Zhu; Li, Ning

    2015-01-01

    Mass spectrometry has been widely applied in characterization and quantification of proteins from complex biological samples. Because the numbers of absolute amounts of proteins are needed in construction of mathematical models for molecular systems of various biological phenotypes and phenomena, a number of quantitative proteomic methods have been adopted to measure absolute quantities of proteins using mass spectrometry. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) coupled with internal peptide standards, i.e., the stable isotope-coded peptide dilution series, which was originated from the field of analytical chemistry, becomes a widely applied method in absolute quantitative proteomics research. This approach provides more and more absolute protein quantitation results of high confidence. As quantitative study of posttranslational modification (PTM) that modulates the biological activity of proteins is crucial for biological science and each isoform may contribute a unique biological function, degradation, and/or subcellular location, the absolute quantitation of protein PTM isoforms has become more relevant to its biological significance. In order to obtain the absolute cellular amount of a PTM isoform of a protein accurately, impacts of protein fractionation, protein enrichment, and proteolytic digestion yield should be taken into consideration and those effects before differentially stable isotope-coded PTM peptide standards are spiked into sample peptides have to be corrected. Assisted with stable isotope-labeled peptide standards, the absolute quantitation of isoforms of posttranslationally modified protein (AQUIP) method takes all these factors into account and determines the absolute amount of a protein PTM isoform from the absolute amount of the protein of interest and the PTM occupancy at the site of the protein. The absolute amount of the protein of interest is inferred by quantifying both the absolute amounts of a few PTM

  10. Absolute cross-section normalization of magnetic neutron scattering data.

    PubMed

    Xu, Guangyong; Xu, Zhijun; Tranquada, J M

    2013-08-01

    We discuss various methods to obtain the resolution volume for neutron scattering experiments, in order to perform absolute normalization on inelastic magnetic neutron scattering data. Examples from previous experiments are given. We also try to provide clear definitions of a number of physical quantities which are commonly used to describe neutron magnetic scattering results, including the dynamic spin correlation function and the imaginary part of the dynamic susceptibility. Formulas that can be used for general purposes are provided and the advantages of the different normalization processes are discussed.

  11. Absolute cross-section normalization of magnetic neutron scattering data

    NASA Astrophysics Data System (ADS)

    Xu, Guangyong; Xu, Zhijun; Tranquada, J. M.

    2013-08-01

    We discuss various methods to obtain the resolution volume for neutron scattering experiments, in order to perform absolute normalization on inelastic magnetic neutron scattering data. Examples from previous experiments are given. We also try to provide clear definitions of a number of physical quantities which are commonly used to describe neutron magnetic scattering results, including the dynamic spin correlation function and the imaginary part of the dynamic susceptibility. Formulas that can be used for general purposes are provided and the advantages of the different normalization processes are discussed.

  12. Application of CO2 waveform in the alveolar recruitment maneuvers of hypoxemic patients during one-lung ventilation

    PubMed Central

    Dong, Chunshan; Yu, Junma; Liu, Qi; Wu, Chao; Lu, Yao

    2016-01-01

    Abstract Deterioration of gas exchange during one-lung ventilation (OLV) is caused by both total collapse of the nondependent lung and partial collapse of the dependent lung. Alveolar recruitment maneuver improves lung function during general anesthesia. The objective of this study was to investigate whether there is an indirect relationship between the changes of CO2 expirogram and the selective lung recruitment. To further improve the oxygenation and gas exchange, we compare adjust setting of ventilated parameters based on CO2 expirogram and a preset setting of ventilated parameters during OLV in patients undergoing right-side thoracic surgery. Thirty patients met the requirements criteria that were studied at 3 time points: during two-lung ventilation (TLV), during OLV with preset ventilation parameters (OLV-PP), and during OLV with adjustable ventilation parameters (OLV-AP) that are in accordance with CO2 expirogram. Adjustable ventilation parameters such as tidal volume (VT), respiratory rate (RR), positive end-expiratory pressure (PEEP), and the ratio of inspiratory to expiratory were adjusted by utilizing the phase III slopes of CO2 expirogram, which together with the relationship between the changes of CO2 expirogram and the selective lung recruitment. During OLV, the phase III slopes of CO2 expirogram in patients with pulse oxymetry (SpO2) decreased less than 93% after the OLV-PP, and were absolutely different from that during TLV. After OLV-AP, the phase III slopes of CO2 expirogram and SpO2 were similar to those during TLV. During OLV, however, parameters of ventilation setting in both OLV-PP and OLV-AP are obviously different. This study indicates that alveolar recruitment by utilizing CO2 expirogram probably improves SpO2 level during one-lung ventilation. PMID:27310989

  13. Application of CO2 waveform in the alveolar recruitment maneuvers of hypoxemic patients during one-lung ventilation.

    PubMed

    Dong, Chunshan; Yu, Junma; Liu, Qi; Wu, Chao; Lu, Yao

    2016-06-01

    Deterioration of gas exchange during one-lung ventilation (OLV) is caused by both total collapse of the nondependent lung and partial collapse of the dependent lung. Alveolar recruitment maneuver improves lung function during general anesthesia. The objective of this study was to investigate whether there is an indirect relationship between the changes of CO2 expirogram and the selective lung recruitment. To further improve the oxygenation and gas exchange, we compare adjust setting of ventilated parameters based on CO2 expirogram and a preset setting of ventilated parameters during OLV in patients undergoing right-side thoracic surgery.Thirty patients met the requirements criteria that were studied at 3 time points: during two-lung ventilation (TLV), during OLV with preset ventilation parameters (OLV-PP), and during OLV with adjustable ventilation parameters (OLV-AP) that are in accordance with CO2 expirogram. Adjustable ventilation parameters such as tidal volume (VT), respiratory rate (RR), positive end-expiratory pressure (PEEP), and the ratio of inspiratory to expiratory were adjusted by utilizing the phase III slopes of CO2 expirogram, which together with the relationship between the changes of CO2 expirogram and the selective lung recruitment.During OLV, the phase III slopes of CO2 expirogram in patients with pulse oxymetry (SpO2) decreased less than 93% after the OLV-PP, and were absolutely different from that during TLV. After OLV-AP, the phase III slopes of CO2 expirogram and SpO2 were similar to those during TLV. During OLV, however, parameters of ventilation setting in both OLV-PP and OLV-AP are obviously different.This study indicates that alveolar recruitment by utilizing CO2 expirogram probably improves SpO2 level during one-lung ventilation.

  14. Absolute realization of low BRDF value

    NASA Astrophysics Data System (ADS)

    Liu, Zilong; Liao, Ningfang; Li, Ping; Wang, Yu

    2010-10-01

    Low BRDF value is widespread used in many critical domains such as space and military fairs. These values below 0.1 Sr-1 . So the Absolute realization of these value is the most critical issue in the absolute measurement of BRDF. To develop the Absolute value realization theory of BRDF , defining an arithmetic operators of BRDF , achieving an absolute measurement Eq. of BRDF based on radiance. This is a new theory method to solve the realization problem of low BRDF value. This theory method is realized on a self-designed common double orientation structure in space. By designing an adding structure to extend the range of the measurement system and a control and processing software, Absolute realization of low BRDF value is achieved. A material of low BRDF value is measured in this measurement system and the spectral BRDF value are showed within different angles allover the space. All these values are below 0.4 Sr-1 . This process is a representative procedure about the measurement of low BRDF value. A corresponding uncertainty analysis of this measurement data is given depend on the new theory of absolute realization and the performance of the measurement system. The relative expand uncertainty of the measurement data is 0.078. This uncertainty analysis is suitable for all measurements using the new theory of absolute realization and the corresponding measurement system.

  15. Lung imaging in rodents using dual energy micro-CT

    NASA Astrophysics Data System (ADS)

    Badea, C. T.; Guo, X.; Clark, D.; Johnston, S. M.; Marshall, C.; Piantadosi, C.

    2012-03-01

    Dual energy CT imaging is expected to play a major role in the diagnostic arena as it provides material decomposition on an elemental basis. The purpose of this work is to investigate the use of dual energy micro-CT for the estimation of vascular, tissue, and air fractions in rodent lungs using a post-reconstruction three-material decomposition method. We have tested our method using both simulations and experimental work. Using simulations, we have estimated the accuracy limits of the decomposition for realistic micro-CT noise levels. Next, we performed experiments involving ex vivo lung imaging in which intact lungs were carefully removed from the thorax, were injected with an iodine-based contrast agent and inflated with air at different volume levels. Finally, we performed in vivo imaging studies in (n=5) C57BL/6 mice using fast prospective respiratory gating in endinspiration and end-expiration for three different levels of positive end-expiratory pressure (PEEP). Prior to imaging, mice were injected with a liposomal blood pool contrast agent. The mean accuracy values were for Air (95.5%), Blood (96%), and Tissue (92.4%). The absolute accuracy in determining all fraction materials was 94.6%. The minimum difference that we could detect in material fractions was 15%. As expected, an increase in PEEP levels for the living mouse resulted in statistically significant increases in air fractions at end-expiration, but no significant changes in end-inspiration. Our method has applicability in preclinical pulmonary studies where various physiological changes can occur as a result of genetic changes, lung disease, or drug effects.

  16. Dose-Volume Analysis of Radiation Pneumonitis in Non-Small-Cell Lung Cancer Patients Treated With Concurrent Cisplatinum and Etoposide With or Without Consolidation Docetaxel

    SciTech Connect

    Barriger, R. Bryan; Fakiris, Achilles J.; Hanna, Nasser; Yu Menggang; Mantravadi, Prasad; McGarry, Ronald C.

    2010-12-01

    Purpose: To examine the rates and risk factors for radiation pneumonitis (RP) in non-small-cell lung cancer (NSCLC) patients treated with chemoradiotherapy. Methods and Materials: We reviewed dosimetry records from Stage III NSCLC patients treated on a prospective randomized trial. Patients received concurrent cisplatinum/etoposide with radiation therapy to 59.4Gy. A total of 243 patients were enrolled; 167 did not experience progression and were randomized to observation (OB) or consolidation docetaxel (CD). Toxicity was coded based on the presence of Grade 0 to 1 vs. Grade 2 to 5 RP using the Common Toxicity Criteria and Adverse Events (CTCAE) v3.0. Results: Median age and follow-up were 63 years and 16 months, respectively. Overall, Grade 0 to 1 and Grade 2 to 5 RP were reported in 226 patients and 17 patients (7%) respectively. Median mean lung dose (MLD), V5, V20, and V30 for evaluable patients were 18 Gy, 52%, 35%, and 29%. MLD in Grade 0 to 1 and Grade 2 to 5 patients was 1,748 c Gy and 2,013 cGy in respectively (p = 0.12). Grade 2 to 5 RP developed in 2.2% and 19% of patients with MLD < 18 Gy and MLD > 18 Gy, respectively (p = 0.015). Mean V20 was 33.7% and 37.7% for Grade 0 to 1 and Grade 2 to 5 groups, respectively (p = 0.29). Grade 2 to 5 RP developed in 4.8% and 17% of patients with V20 < 35% and V20 > 35%, respectively. The OB and CD groups had similar MLD and V20, and the RP rates were 3.6% and 14.6%, respectively (p = 0.015). Patients who developed Grade 0 to 1 and Grade 2 to 5 RP had similar mean V5, V10, V15, V20, V25, V30, age, smoking history, and tumor characteristics. Conclusions: The overall rate of Grade 2 to 5 RP was 7% in patients treated with chemoradiotherapy. In this analysis, predictive factors for RP were MLD > 18 Gy and treatment with CD.

  17. Lung Cancer

    MedlinePlus

    Lung cancer is one of the most common cancers in the world. It is a leading cause of cancer death in men and women in the United States. Cigarette smoking causes most lung cancers. The more cigarettes you smoke per day and ...

  18. Lung Cancer

    MedlinePlus

    ... has been a steady drop in lung cancer deaths among men, mainly because fewer men are smoking, and since the turn of the century, lung cancer deaths in women have been slowly declining. Cigarette smoking rates had been dropping steadily in the 1990s ...

  19. Lung transplantation

    PubMed Central

    Afonso, José Eduardo; Werebe, Eduardo de Campos; Carraro, Rafael Medeiros; Teixeira, Ricardo Henrique de Oliveira Braga; Fernandes, Lucas Matos; Abdalla, Luis Gustavo; Samano, Marcos Naoyuki; Pêgo-Fernandes, Paulo Manuel

    2015-01-01

    ABSTRACT Lung transplantation is a globally accepted treatment for some advanced lung diseases, giving the recipients longer survival and better quality of life. Since the first transplant successfully performed in 1983, more than 40 thousand transplants have been performed worldwide. Of these, about seven hundred were in Brazil. However, survival of the transplant is less than desired, with a high mortality rate related to primary graft dysfunction, infection, and chronic graft dysfunction, particularly in the form of bronchiolitis obliterans syndrome. New technologies have been developed to improve the various stages of lung transplant. To increase the supply of lungs, ex vivo lung reconditioning has been used in some countries, including Brazil. For advanced life support in the perioperative period, extracorporeal membrane oxygenation and hemodynamic support equipment have been used as a bridge to transplant in critically ill patients on the waiting list, and to keep patients alive until resolution of the primary dysfunction after graft transplant. There are patients requiring lung transplant in Brazil who do not even come to the point of being referred to a transplant center because there are only seven such centers active in the country. It is urgent to create new centers capable of performing lung transplantation to provide patients with some advanced forms of lung disease a chance to live longer and with better quality of life. PMID:26154550

  20. Lung Diseases

    MedlinePlus

    When you breathe, your lungs take in oxygen from the air and deliver it to the bloodstream. The cells in your body need oxygen to ... you breathe nearly 25,000 times. People with lung disease have difficulty breathing. Millions of people in ...

  1. A New Gimmick for Assigning Absolute Configuration.

    ERIC Educational Resources Information Center

    Ayorinde, F. O.

    1983-01-01

    A five-step procedure is provided to help students in making the assignment absolute configuration less bothersome. Examples for both single (2-butanol) and multi-chiral carbon (3-chloro-2-butanol) molecules are included. (JN)

  2. Magnifying absolute instruments for optically homogeneous regions

    SciTech Connect

    Tyc, Tomas

    2011-09-15

    We propose a class of magnifying absolute optical instruments with a positive isotropic refractive index. They create magnified stigmatic images, either virtual or real, of optically homogeneous three-dimensional spatial regions within geometrical optics.

  3. The Simplicity Argument and Absolute Morality

    ERIC Educational Resources Information Center

    Mijuskovic, Ben

    1975-01-01

    In this paper the author has maintained that there is a similarity of thought to be found in the writings of Cudworth, Emerson, and Husserl in his investigation of an absolute system of morality. (Author/RK)

  4. What Is Lung Cancer?

    MedlinePlus

    ... Graphics Infographic Stay Informed Cancer Home What Is Lung Cancer? Language: English Español (Spanish) Recommend on Facebook Tweet ... cancer starts in the lungs, it is called lung cancer. Lung cancer begins in the lungs and may ...

  5. Lung disease - resources

    MedlinePlus

    Resources - lung disease ... The following organizations are good resources for information on lung disease : American Lung Association -- www.lung.org National Heart, Lung, and Blood Institute -- www.nhlbi.nih.gov ...

  6. Absolute cross sections of compound nucleus reactions

    NASA Astrophysics Data System (ADS)

    Capurro, O. A.

    1993-11-01

    The program SEEF is a Fortran IV computer code for the extraction of absolute cross sections of compound nucleus reactions. When the evaporation residue is fed by its parents, only cumulative cross sections will be obtained from off-line gamma ray measurements. But, if one has the parent excitation function (experimental or calculated), this code will make it possible to determine absolute cross sections of any exit channel.

  7. Kelvin and the absolute temperature scale

    NASA Astrophysics Data System (ADS)

    Erlichson, Herman

    2001-07-01

    This paper describes the absolute temperature scale of Kelvin (William Thomson). Kelvin found that Carnot's axiom about heat being a conserved quantity had to be abandoned. Nevertheless, he found that Carnot's fundamental work on heat engines was correct. Using the concept of a Carnot engine Kelvin found that Q1/Q2 = T1/T2. Thermometers are not used to obtain absolute temperatures since they are calculated temperatures.

  8. Limitations to exercise in female centenarians: evidence that muscular efficiency tempers the impact of failing lungs.

    PubMed

    Venturelli, Massimo; Schena, Federico; Scarsini, Renato; Muti, Ettore; Richardson, Russell S

    2013-06-01

    Centenarians are an outstanding model of successful aging, with genetics and healthy lifestyle certainly being key factors responsible for their longevity. Exercise capacity has been identified to play an important role in healthy aging, but a comprehensive assessment of the limitations to maximal exercise in this population is lacking. Following, health histories, lung function, and anthropometric measures, eight female centenarians (98-102 years old) and eight young females (18-22 years old) performed a series of graded maximal exercise tests on a cycle ergometer that facilitated absolute and relative work rate comparisons. Centenarians revealed a dramatically attenuated lung function, as measured by spirometry (forced expiratory volume in 1 s (FEV1/forced vital capacity (FVC), 55 ± 10%) compared to the young (FEV1/FVC, 77 ± 5%). During exercise, although the centenarians relied heavily on respiratory rate which yielded ~50% higher dead space/tidal volume, minute ventilation was similar to that of the young at all but maximal exercise, and alveolar PO2 was maintained in both groups. In contrast, peak WR and VO2 were significantly reduced in the centenarians (33 ± 4 vs 179 ± 24 W; 7.5 ± 1.2 vs 39.6 ± 3.5 ml min(-1) kg(-1)). Arterial PO2 of the centenarians fell steadily from the normal range of both groups to yield a large A-a gradient (57 ± 6 mmHg). Metabolic cost of a given absolute work rate was consistently lower, ~46% less than the young at maximal effort. Centenarians have significant limitations to gas exchange across the lungs during exercise, but this limited oxygen transport is tempered by improved skeletal muscle mechanical efficiency that may play a vital role in maintaining physical function and therefore longevity in this population.

  9. Crystal structure of meteoritic schreibersites: determination of absolute structure

    NASA Astrophysics Data System (ADS)

    Skála, Roman; Císařová, Ivana

    Minerals of the schreibersite nickelphosphide series (Fe,Ni)3P crystallize in the non-centrosymmetric space group Ibar 4. As a consequence, they can possess two different spatial arrangements of the constituting atoms within the unit cell, related by the inversion symmetry operation. Here, we present the crystal structure refinements from single crystal X-ray diffraction data for schreibersite grains from iron meteorites Acuña, Carlton, Hex River Mts. (three different crystals), Odessa (two different crystals), Sikhote Alin, and Toluca aiming for the determination of the absolute structure of the examined crystals. The crystals studied cover the composition range from 58 mol% to 80 mol% Fe3P end-member. Unit-cell parameter a and volume of the unit cell V, as well as certain topological structural parameters tightly correlate with Fe3P content. Unit-cell parameter c, on the other hand, does not show such strong correlation. Eight of the nine crystal structure refinements allowed unambiguous absolute structure assignment. The single crystal extracted from Toluca is, however, of poor quality and consequently the structure refinement did not provide as good results as the rest of the materials. Also, this crystal has only weak inversion distinguishing power to provide unequivocal absolute structure determination. Six of the eight unambiguous absolute structure determinations indicated inverted atomic arrangement compared to that reported in earlier structure refinements (here called standard). Only two grains, one taken from Odessa iron and the other from the Hex River Mts. meteorite, reveal the dominance of standard crystal structure setting.

  10. Impact of 18FDG-PET/CT on biological target volume (BTV) definition for treatment planning for non-small cell lung cancer patients

    NASA Astrophysics Data System (ADS)

    Devic, Slobodan; Tomic, Nada; Faria, Sergio; Dean, Geoffrey; Lisbona, Robert; Parker, William; Kaufman, Chris; Podgorsak, Ervin B.

    2007-02-01

    This work represents our effort to test feasibility of FDG-based PET/CT on target volume delineation in radiotherapy treatment planning of NSCLC patients. Different methods have been developed to enable more precise target outlining using PET: Qualitative Visual Method, CTV=2.5 SUV units, linear SUV threshold function method, and CTV=40% Iso of Maximum Uptake Value. We are proposing reconstruction of three biological target volumes: necrotic BTV (same as PTV created by radiation oncologist using CT data), proliferating BTV (based on PET signal to background ratio 1:3) and hypoxic BTV (based on PET signal to background ratio of 1:19). Two IMRT plans were created and compared to the conventional treatment plan: "conservative" IMRT plan delivers 52.5 Gy to the necrotic BTV and 65 Gy to the hypoxic BTV; "radical" IMRT plan delivers 30 Gy to necrotic BTV, 52.5 Gy to proliferating BTV and 65 Gy to hypoxic BTV. Use of BTVs in IMRT plans is attractive because it increases dose to targets considered to need higher doses. It reduces considerably dose to heart and spinal cord, organs considered to limit dose escalation approaches in NSCLC treatment. "Conservative" IMRT approach can be understood as a PET/CT-based concomitant boost to the tumor expressing the highest FDG uptake. "Radical" plan implies deviation from the traditional uniform dose target coverage approach, with the intention of achieving better surrounding tissue sparing and ultimately allowing for dose escalation protocols relying on biologically based treatment planning.

  11. Absolute counting of neutrophils in whole blood using flow cytometry.

    PubMed

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens.

  12. Early COPD patients with lung hyperinflation associated with poorer lung function but better bronchodilator responsiveness

    PubMed Central

    Chen, Chunlan; Jian, Wenhua; Gao, Yi; Xie, Yanqing; Song, Yan; Zheng, Jinping

    2016-01-01

    Background It is unknown whether aggressive medication strategies should be used for early COPD with or without lung hyperinflation. We aimed to explore the characteristics and bronchodilator responsiveness of early COPD patients (stages I and II) with/without lung hyperinflation. Methods Four hundred and six patients with COPD who performed both lung volume and bronchodilation tests were retrospectively analyzed. Residual volume to total lung capacity >120% of predicted values indicated lung hyperinflation. The characteristics and bronchodilator responsiveness were compared between the patients with and without lung hyperinflation across all stages of COPD. Results The percentages of patients with lung hyperinflation were 72.7% in the entire cohort, 19.4% in stage I, 68.5% in stage II, 95.3% in stage III, and 100.0% in stage IV. The patients with lung hyperinflation exhibited poorer lung function but better bronchodilator responsiveness of both forced expiratory volume in 1 second and forced vital capacity than those without lung hyperinflation during early COPD (t=2.21–5.70, P=0.000–0.029), especially in stage I, while age, body mass index, smoking status, smoking history, and disease duration were similar between the two subgroups in the same stages. From stages I to IV of subgroups with lung hyperinflation, stage I patients had the best bronchodilator responsiveness. Use of bronchodilator responsiveness of forced vital capacity to detect the presence of lung hyperinflation in COPD patients showed relatively high sensitivities (69.5%–75.3%) and specificities (70.3%–75.7%). Conclusion We demonstrated the novel finding that early COPD patients with lung hyperinflation are associated with poorer lung function but better bronchodilator responsiveness and established a simple method for detecting lung hyperinflation. PMID:27785008

  13. Jasminum flexile flower absolute from India--a detailed comparison with three other jasmine absolutes.

    PubMed

    Braun, Norbert A; Kohlenberg, Birgit; Sim, Sherina; Meier, Manfred; Hammerschmidt, Franz-Josef

    2009-09-01

    Jasminum flexile flower absolute from the south of India and the corresponding vacuum headspace (VHS) sample of the absolute were analyzed using GC and GC-MS. Three other commercially available Indian jasmine absolutes from the species: J. sambac, J. officinale subsp. grandiflorum, and J. auriculatum and the respective VHS samples were used for comparison purposes. One hundred and twenty-one compounds were characterized in J. flexile flower absolute, with methyl linolate, benzyl salicylate, benzyl benzoate, (2E,6E)-farnesol, and benzyl acetate as the main constituents. A detailed olfactory evaluation was also performed.

  14. Regional differences in alveolar density in the human lung are related to lung height.

    PubMed

    McDonough, John E; Knudsen, Lars; Wright, Alexander C; Elliott, W Mark; Ochs, Matthias; Hogg, James C

    2015-06-01

    The gravity-dependent pleural pressure gradient within the thorax produces regional differences in lung inflation that have a profound effect on the distribution of ventilation within the lung. This study examines the hypothesis that gravitationally induced differences in stress within the thorax also influence alveolar density in terms of the number of alveoli contained per unit volume of lung. To test this hypothesis, we measured the number of alveoli within known volumes of lung located at regular intervals between the apex and base of four normal adult human lungs that were rapidly frozen at a constant transpulmonary pressure, and used microcomputed tomographic imaging to measure alveolar density (number alveoli/mm3) at regular intervals between the lung apex and base. These results show that at total lung capacity, alveolar density in the lung apex is 31.6 ± 3.4 alveoli/mm3, with 15 ± 6% of parenchymal tissue consisting of alveolar duct. The base of the lung had an alveolar density of 21.2 ± 1.6 alveoli/mm3 and alveolar duct volume fraction of 29 ± 6%. The difference in alveolar density can be negated by factoring in the effects of alveolar compression due to the pleural pressure gradient at the base of the lung in vivo and at functional residual capacity.

  15. Universal Cosmic Absolute and Modern Science

    NASA Astrophysics Data System (ADS)

    Kostro, Ludwik

    The official Sciences, especially all natural sciences, respect in their researches the principle of methodic naturalism i.e. they consider all phenomena as entirely natural and therefore in their scientific explanations they do never adduce or cite supernatural entities and forces. The purpose of this paper is to show that Modern Science has its own self-existent, self-acting, and self-sufficient Natural All-in Being or Omni-Being i.e. the entire Nature as a Whole that justifies the scientific methodic naturalism. Since this Natural All-in Being is one and only It should be considered as the own scientifically justified Natural Absolute of Science and should be called, in my opinion, the Universal Cosmic Absolute of Modern Science. It will be also shown that the Universal Cosmic Absolute is ontologically enormously stratified and is in its ultimate i.e. in its most fundamental stratum trans-reistic and trans-personal. It means that in its basic stratum. It is neither a Thing or a Person although It contains in Itself all things and persons with all other sentient and conscious individuals as well, On the turn of the 20th century the Science has begun to look for a theory of everything, for a final theory, for a master theory. In my opinion the natural Universal Cosmic Absolute will constitute in such a theory the radical all penetrating Ultimate Basic Reality and will substitute step by step the traditional supernatural personal Absolute.

  16. Lung Transplant

    MedlinePlus

    ... will recover in the hospital’s intensive care unit (ICU) before moving to a hospital room for one to three weeks. Your doctor may recommend pulmonary rehabilitation after your lung transplant surgery to help you ...

  17. Fast, Computer Supported Experimental Determination of Absolute Zero Temperature at School

    ERIC Educational Resources Information Center

    Bogacz, Bogdan F.; Pedziwiatr, Antoni T.

    2014-01-01

    A simple and fast experimental method of determining absolute zero temperature is presented. Air gas thermometer coupled with pressure sensor and data acquisition system COACH is applied in a wide range of temperature. By constructing a pressure vs temperature plot for air under constant volume it is possible to obtain--by extrapolation to zero…

  18. Mathematical modeling of gravitational effects on the circulation: importance of the time course of venous pooling and blood volume changes in the lungs.

    PubMed

    van Heusden, K; Gisolf, J; Stok, W J; Dijkstra, S; Karemaker, J M

    2006-11-01

    A dip in blood pressure (BP) in response to head-up tilt (HUT) or active standing might be due to rapid pooling in the veins below the heart (preload) or muscle activation-induced drop in systemic vascular resistance (afterload). We hypothesized that, in the cardiovascular response to passive HUT, where, in contrast to active standing, little BP dip is observed, features affecting the preload play a key role. We developed a baroreflex model combined with a lumped-parameter model of the circulation, including viscoelastic stress-relaxation of the systemic veins. Cardiac contraction is modeled using the varying-elastance concept. Gravity affects not only the systemic, but also the pulmonary, circulation. In accordance with the experimental results, model simulations do not show a BP dip on HUT; the tilt-back response is also realistic. If it is assumed that venous capacities are steady-state values, the introduction of stress-relaxation initially reduces venous pooling. The resulting time course of venous pooling is comparable to measured impedance changes. When venous pressure-volume dynamics are neglected, rapid (completed within 30 s) venous pooling leads to a drop in BP. The direct effect of gravity on the pulmonary circulation influences the BP response in the first approximately 5 s after HUT and tilt back. In conclusion, the initial BP response to HUT is mainly determined by the response of the venous system. The time course of lower body pooling is essential in understanding the response to passive HUT.

  19. In-vivo Comparison of 18F-FLT uptake, CT Number, Tumor Volume in Evaluation of Repopulation during Radiotherapy for Lung cancer

    PubMed Central

    Zhang, Xiaoli; Yu, Jinming; Li, Chengming; Sun, Xindong; Meng, Xue

    2017-01-01

    Accelerated repopulation has been observed in various tumors. This study was aimed to evaluate the potential of 3′-deoxy-3′-18F-fluorothymidine (18F-FLT) uptake and Computed Tomography Number (CTN) in monitoring tumor responses to radiotherapy compared with tumor volume (TV) changes. Tumor bearing nude mice were assigned to either irradiated daily or every second day group and then randomized to 6 sub-groups to receive 0Gy, 6Gy, 12Gy, 18Gy, 24Gy, 36Gy irradiation, respectively. TV was measured every 3 days. 18F-FLT micro-PET/CT scans were performed after irradiation being completed. Tumor sections were stained to calculate the immunohistochemical (Ki-67) labeling index (LI). Comparison analysis between FLT uptake parameters, CTNs, VTs and Ki-67 LI results were conducted to determine the correlation. Ki-67 LI increased significantly after 6 times of irradiation at irradiated daily group and after 3 times at irradiated every second day group, suggesting accelerated repopulation. No shrinkage of TV was noticed at two groups during irradiation delivery. Both 18F-FLT uptake and CTN increased significantly after irradiation of 12Gy/6f/6d and 6Gy/3f/6d. Comparison analysis found a significant relationship between Ki-67 LI and 18F-FLT uptake parameters as well as CTN. Both 18F-FLT PET and CT have the potential to reflect the tumor proliferative response during radiation delivery. PMID:28387306

  20. Quantitative standards for absolute linguistic universals.

    PubMed

    Piantadosi, Steven T; Gibson, Edward

    2014-01-01

    Absolute linguistic universals are often justified by cross-linguistic analysis: If all observed languages exhibit a property, the property is taken to be a likely universal, perhaps specified in the cognitive or linguistic systems of language learners and users. In many cases, these patterns are then taken to motivate linguistic theory. Here, we show that cross-linguistic analysis will very rarely be able to statistically justify absolute, inviolable patterns in language. We formalize two statistical methods--frequentist and Bayesian--and show that in both it is possible to find strict linguistic universals, but that the numbers of independent languages necessary to do so is generally unachievable. This suggests that methods other than typological statistics are necessary to establish absolute properties of human language, and thus that many of the purported universals in linguistics have not received sufficient empirical justification.

  1. Lack of a Dose-Effect Relationship for Pulmonary Function Changes After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

    SciTech Connect

    Guckenberger, Matthias; Klement, Rainer J.; Kestin, Larry L.; Hope, Andrew J.; Belderbos, Jose; Werner-Wasik, Maria; Yan, Di; Sonke, Jan-Jakob; Bissonnette, Jean-Pierre; Xiao, Ying; Grills, Inga S.

    2013-03-15

    Purpose: To evaluate the influence of tumor size, prescription dose, and dose to the lungs on posttreatment pulmonary function test (PFT) changes after stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (NSCLC). Methods and Materials: The analysis is based on 191 patients treated at 5 international institutions: inclusion criteria were availability of pre- and post-SBRT PFTs and dose-volume histograms of the lung and planning target volume (PTV); patients treated with more than 1 SBRT course were excluded. Correlation between early (1-6 months, median 3 months) and late (7-24 months, median 12 months) PFT changes and tumor size, planning target volume (PTV) dose, and lung doses was assessed using linear regression analysis, receiver operating characteristics analysis, and Lyman's normal tissue complication probability model. The PTV doses were converted to biologically effective doses and lung doses to 2 Gy equivalent doses before correlation analyses. Results: Up to 6 months after SBRT, forced expiratory volume in 1 second and carbon monoxide diffusion capacity changed by −1.4% (95% confidence interval [CI], −3.4% to 0) and −7.6% (95% CI, −10.2% to −3.4%) compared with pretreatment values, respectively. A modest decrease in PFTs was observed 7-24 months after SBRT, with changes of −8.1% (95% CI, −13.3% to −5.3%) and −12.4% (95% CI, −15.5% to −6.9%), respectively. Using linear regression analysis, receiver operating characteristic analysis, and normal tissue complication probability modeling, all evaluated parameters of tumor size, PTV dose, mean lung dose, and absolute and relative volumes of the lung exposed to minimum doses of 5-70 Gy were not correlated with early and late PFT changes. Subgroup analysis based on pre-SBRT PFTs (greater or equal and less than median) did not identify any dose-effect relationship. Conclusions: This study failed to demonstrate a significant dose-effect relationship for

  2. Absolute Distance Measurement with the MSTAR Sensor

    NASA Technical Reports Server (NTRS)

    Lay, Oliver P.; Dubovitsky, Serge; Peters, Robert; Burger, Johan; Ahn, Seh-Won; Steier, William H.; Fetterman, Harrold R.; Chang, Yian

    2003-01-01

    The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. The sensor uses a single laser in conjunction with fast phase modulators and low frequency detectors. We describe the design of the system - the principle of operation, the metrology source, beamlaunching optics, and signal processing - and show results for target distances up to 1 meter. We then demonstrate how the system can be scaled to kilometer-scale distances.

  3. Absolutely relative or relatively absolute: violations of value invariance in human decision making.

    PubMed

    Teodorescu, Andrei R; Moran, Rani; Usher, Marius

    2016-02-01

    Making decisions based on relative rather than absolute information processing is tied to choice optimality via the accumulation of evidence differences and to canonical neural processing via accumulation of evidence ratios. These theoretical frameworks predict invariance of decision latencies to absolute intensities that maintain differences and ratios, respectively. While information about the absolute values of the choice alternatives is not necessary for choosing the best alternative, it may nevertheless hold valuable information about the context of the decision. To test the sensitivity of human decision making to absolute values, we manipulated the intensities of brightness stimuli pairs while preserving either their differences or their ratios. Although asked to choose the brighter alternative relative to the other, participants responded faster to higher absolute values. Thus, our results provide empirical evidence for human sensitivity to task irrelevant absolute values indicating a hard-wired mechanism that precedes executive control. Computational investigations of several modelling architectures reveal two alternative accounts for this phenomenon, which combine absolute and relative processing. One account involves accumulation of differences with activation dependent processing noise and the other emerges from accumulation of absolute values subject to the temporal dynamics of lateral inhibition. The potential adaptive role of such choice mechanisms is discussed.

  4. Mild loss of lung aeration augments stretch in healthy lung regions

    PubMed Central

    Xin, Yi; Hamedani, Hooman; Clapp, Justin; Kadlecek, Stephen; Meeder, Natalie; Zeng, Johnathan; Profka, Harrilla; Kavanagh, Brian P.; Rizi, Rahim R.

    2015-01-01

    Inspiratory stretch by mechanical ventilation worsens lung injury. However, it is not clear whether and how the ventilator damages lungs in the absence of preexisting injury. We hypothesized that subtle loss of lung aeration during general anesthesia regionally augments ventilation and distension of ventilated air spaces. In eight supine anesthetized and intubated rats, hyperpolarized gas MRI was performed after a recruitment maneuver following 1 h of volume-controlled ventilation with zero positive end-expiratory pressure (ZEEP), FiO2 0.5, and tidal volume 10 ml/kg, and after a second recruitment maneuver. Regional fractional ventilation (FV), apparent diffusion coefficient (ADC) of 3He (a measurement of ventilated peripheral air space dimensions), and gas volume were measured in lung quadrants of ventral and dorsal regions of the lungs. In six additional rats, computed tomography (CT) images were obtained at each time point. Ventilation with ZEEP decreased total lung gas volume and increased both FV and ADC in all studied regions. Increases in FV were more evident in the dorsal slices. In each lung quadrant, higher ADC was predicted by lower gas volume and by increased mean values (and heterogeneity) of FV distribution. CT scans documented 10% loss of whole-lung aeration and increased density in the dorsal lung, but no macroscopic atelectasis. Loss of pulmonary gas at ZEEP increased fractional ventilation and inspiratory dimensions of ventilated peripheral air spaces. Such regional changes could help explain a propensity for mechanical ventilation to contribute to lung injury in previously uninjured lungs. PMID:26662053

  5. Age-specific absolute and relative organ weight distributions for Fischer 344 rats.

    PubMed

    Marino, Dale J

    2012-01-01

    The Fischer 344 (F344) rat has been the standard rat strain used in toxicology studies conducted by the National Cancer Institute (NCI) and the National Toxicology Program (NTP). However, the numerous reports published to date on growth, survival, and tumor incidence have not included an overall compilation of organ weight data. Notably, dose-related organ weight effects are endpoints used by regulatory agencies to develop toxicity reference values (TRVs) for use in human health risk assessments. In addition, physiologically-based pharmacokinetic (PBPK) models, which utilize relative organ weights, are increasingly being used to develop TRVs. Because a compilation of organ weights for F344 rats could prove beneficial for TRV development and PBPK modeling, all available absolute and relative organ weight data for untreated control F344 rats were collected from NCI/NTP feed, drinking-water, and inhalation studies in order to develop age-specific distributions. Results showed that organ weights were collected more frequently at 2-wk (59 studies), 3-mo (148 studies), and 15-mo (38 studies) intervals than at other intervals and more frequently from feeding and inhalation than from drinking-water studies. Liver, right kidney, lung, heart, thymus, and brain weights were most frequently collected. From the collected data, the mean and standard deviation for absolute and relative organ weights were calculated. Findings showed age-related increases in absolute weights and decreases in relative weights for brain, liver, right kidney, lung, heart, thyroid, and right testis. The results suggest a general variability trend in absolute organ weights of brain < right testis < heart < right kidney < liver < lung < thymus < thyroid.

  6. Impact of tumor volume doubling time on post-metastatic survival in bone or soft-tissue sarcoma patients treated with metastasectomy and/or radiofrequency ablation of the lung

    PubMed Central

    Nakamura, Tomoki; Matsumine, Akihiko; Takao, Motoshi; Nakatsuka, Atsuhiro; Matsubara, Takao; Asanuma, Kunihiro; Sudo, Akihiro

    2017-01-01

    Metastasectomy represents the standard treatment for improving survival in patients with lung metastases (LMs) from bone (BS) or soft-tissue sarcoma (STS). Recently, radiofrequency ablation (RFA) of the LMs has been proved to be a useful option which can promise the similar effect to metastasectomy. The aim of this study was to determine prognostic factors, including tumor volume doubling time (TVDT), for post-metastatic survival in BS and STS patients treated with metastasectomy and/or RFA of the lung. Forty-eight patients with LMs were retrospectively reviewed. The mean age of the patients at the time of LMs was 56 years. The cohort comprised 27 male and 21 female patients. Eight of the 48 patients had LMs at the point of initial presentation. The mean follow-up period after commencing the treatment for LMs was 37 months. The mean maximum diameter of the initial LMs was 11 mm. The mean number of LMs was 4. The TVDT was calculated using a method originally described by Schwartz. At last follow-up, 5 patients had no evidence of disease, 3 patients were still alive with disease, and 32 patients had died of disease. The 3-year and 5-year post-metastatic survival rates were 32% and 16.8%, respectively. In a Cox univariate analysis, the size (P=0.04) and number of LMs (P<0.001), disease-free interval (P=0.04), curability of the initial LMs (P<0.001), and TVDT (P<0.001) were significantly identified as factors which affect prognosis. In the multivariate analysis, TVDT (P<0.001) and curability of the initial LMs (P<0.001) were confirmed as independent predictors of survival. There was a significant association between the number and curability of the initial LMs (P<0.001). In conclusion, metastasectomy and/or RFA of LMs is recommended for improving survival. However, TVDT and the curability of the LMs should be taken into consideration. PMID:28203089

  7. Rapid learning in practice: A lung cancer survival decision support system in routine patient care data

    PubMed Central

    Dekker, Andre; Vinod, Shalini; Holloway, Lois; Oberije, Cary; George, Armia; Goozee, Gary; Delaney, Geoff P.; Lambin, Philippe; Thwaites, David

    2016-01-01

    Background and purpose A rapid learning approach has been proposed to extract and apply knowledge from routine care data rather than solely relying on clinical trial evidence. To validate this in practice we deployed a previously developed decision support system (DSS) in a typical, busy clinic for non-small cell lung cancer (NSCLC) patients. Material and methods Gender, age, performance status, lung function, lymph node status, tumor volume and survival were extracted without review from clinical data sources for lung cancer patients. With these data the DSS was tested to predict overall survival. Results 3919 lung cancer patients were identified with 159 eligible for inclusion, due to ineligible histology or stage, non-radical dose, missing tumor volume or survival. The DSS successfully identified a good prognosis group and a medium/poor prognosis group (2 year OS 69% vs. 27/30%, p < 0.001). Stage was less discriminatory (2 year OS 47% for stage I–II vs. 36% for stage IIIA–IIIB, p = 0.12) with most good prognosis patients having higher stage disease. The DSS predicted a large absolute overall survival benefit (~40%) for a radical dose compared to a non-radical dose in patients with a good prognosis, while no survival benefit of radical radiotherapy was predicted for patients with a poor prognosis. Conclusions A rapid learning environment is possible with the quality of clinical data sufficient to validate a DSS. It uses patient and tumor features to identify prognostic groups in whom therapy can be individualized based on predicted outcomes. Especially the survival benefit of a radical versus non-radical dose predicted by the DSS for various prognostic groups has clinical relevance, but needs to be prospectively validated. PMID:25241994

  8. Longitudinal changes in lung hyperinflation in COPD

    PubMed Central

    Park, Jimyung; Lee, Chang-Hoon; Lee, Yeon Joo; Park, Jong Sun; Cho, Young-Jae; Lee, Jae Ho; Lee, Choon-Taek; Yoon, Ho Il

    2017-01-01

    Purpose COPD is characterized by an accelerated and progressive decline in forced expiratory volume in 1 second (FEV1) and lung hyperinflation. Although lung hyperinflation is the hallmark of COPD, data on the longitudinal changes in lung hyperinflation and any association with the decline in FEV1 are lacking. The aim of this study was to evaluate the longitudinal changes in lung hyperinflation and to investigate its relationship with FEV1 decline. Patients and methods We conducted a prospective cohort study and studied 176 COPD patients with annual lung volume measurements over a period of 5 years or more. We used a random coefficient model to calculate the annual changes in lung volumes and to evaluate the factors associated with changes in lung hyperinflation. Additionally, the relationship between the change in lung hyperinflation and FEV1 was assessed. Results Residual volume (RV), inspiratory capacity (IC), and total lung capacity (TLC) declined at a mean rate of 39.5, 49.6, and 63.8 mL/year, respectively. While IC/TLC declined at 0.70%/year, RV/TLC also declined at 0.35%/year. Changes in both IC/TLC and RV/TLC varied significantly. Frequent exacerbations led to an increase in RV/TLC and faster decline in IC/TLC over time. RV/TLC declined in 59.7% and increased in 40.3% of the patients. A significant negative correlation was found between the rates of change in FEV1 and RV/TLC, and the rate of decline in FEV1 was greater in patients with an increase in RV/TLC than in those with a decline in RV/TLC (54.2 vs 10.7 mL/year, P<0.001). Conclusion The rate of change in lung hyperinflation varied greatly among COPD patients. Progression of hyperinflation was associated with frequent exacerbations and a faster decline in FEV1. PMID:28223790

  9. Comparative vs. Absolute Judgments of Trait Desirability

    ERIC Educational Resources Information Center

    Hofstee, Willem K. B.

    1970-01-01

    Reversals of trait desirability are studied. Terms indicating conservativw behavior appeared to be judged relatively desirable in comparative judgement, while traits indicating dynamic and expansive behavior benefited from absolute judgement. The reversal effect was shown to be a general one, i.e. reversals were not dependent upon the specific…

  10. New Techniques for Absolute Gravity Measurements.

    DTIC Science & Technology

    1983-01-07

    Hammond, J.A. (1978) Bollettino Di Geofisica Teorica ed Applicata Vol. XX. 8. Hammond, J. A., and Iliff, R. L. (1979) The AFGL absolute gravity system...International Gravimetric Bureau, No. L:I-43. 7. Hammond. J.A. (1978) Bollettino Di Geofisica Teorica ed Applicata Vol. XX. 8. Hammond, J.A., and

  11. An Absolute Electrometer for the Physics Laboratory

    ERIC Educational Resources Information Center

    Straulino, S.; Cartacci, A.

    2009-01-01

    A low-cost, easy-to-use absolute electrometer is presented: two thin metallic plates and an electronic balance, usually available in a laboratory, are used. We report on the very good performance of the device that allows precise measurements of the force acting between two charged plates. (Contains 5 footnotes, 2 tables, and 6 figures.)

  12. Stimulus Probability Effects in Absolute Identification

    ERIC Educational Resources Information Center

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  13. Absolute Positioning Using the Global Positioning System

    DTIC Science & Technology

    1994-04-01

    Global Positioning System ( GPS ) has becom a useful tool In providing relativ survey...Includes the development of a low cost navigator for wheeled vehicles. ABSTRACT The Global Positioning System ( GPS ) has become a useful tool In providing...technique of absolute or point positioning involves the use of a single Global Positioning System ( GPS ) receiver to determine the three-dimenslonal

  14. Closing volume during normal pregnancy.

    PubMed Central

    Garrard, G S; Littler, W A; Redman, C W

    1978-01-01

    Serial lung function studies were performed in ten healthy, primiparous women aged 21--28. Measurements were made at two-monthly intervals during pregnancy and included functional residual capacity (FRC), total lung capacity (TLC), vital capacity (VC), specific conductance (SGaw) and closing volume (CV) on each occasion. Closing volume expressed as formular: (see text), showed a progressive rise during pregnancy in all subjects with a linear relationship to time (P less than 0.001, P greater than 0.01, respectively). No consistent changes in lung volume could be shown during pregnancy over the study period. It is suggested that the increase in closing volume during pregnancy might result in abnormalities of distribution of ventilation sufficient to explain the maternal blood gas disturbances of pregnancy. PMID:694802

  15. Screening and early detection of lung cancer.

    PubMed

    Van't Westeinde, Susan C; van Klaveren, Rob J

    2011-01-01

    Lung cancer with an estimated 342,000 deaths in 2008 (20% of total) is the most common cause of death from cancer, followed by colorectal cancer (12%), breast cancer (8%), and stomach cancer (7%) in Europe. In former smokers, the absolute lung cancer risk remains higher than in never-smokers; these data therefore call for effective secondary preventive measures for lung cancer in addition to smoking cessation programs. This review presents and discusses the most recent advances in the early detection and screening of lung cancer.An overview of randomized controlled computerized tomography-screening trials is given, and the role of bronchoscopy and new techniques is discussed. Finally, the approach of (noninvasive) biomarker testing in the blood, exhaled breath, sputum, and bronchoscopic specimen is reviewed.

  16. Absolute Radiation Thermometry in the NIR

    NASA Astrophysics Data System (ADS)

    Bünger, L.; Taubert, R. D.; Gutschwager, B.; Anhalt, K.; Briaudeau, S.; Sadli, M.

    2017-04-01

    A near infrared (NIR) radiation thermometer (RT) for temperature measurements in the range from 773 K up to 1235 K was characterized and calibrated in terms of the "Mise en Pratique for the definition of the Kelvin" (MeP-K) by measuring its absolute spectral radiance responsivity. Using Planck's law of thermal radiation allows the direct measurement of the thermodynamic temperature independently of any ITS-90 fixed-point. To determine the absolute spectral radiance responsivity of the radiation thermometer in the NIR spectral region, an existing PTB monochromator-based calibration setup was upgraded with a supercontinuum laser system (0.45 μm to 2.4 μm) resulting in a significantly improved signal-to-noise ratio. The RT was characterized with respect to its nonlinearity, size-of-source effect, distance effect, and the consistency of its individual temperature measuring ranges. To further improve the calibration setup, a new tool for the aperture alignment and distance measurement was developed. Furthermore, the diffraction correction as well as the impedance correction of the current-to-voltage converter is considered. The calibration scheme and the corresponding uncertainty budget of the absolute spectral responsivity are presented. A relative standard uncertainty of 0.1 % (k=1) for the absolute spectral radiance responsivity was achieved. The absolute radiometric calibration was validated at four temperature values with respect to the ITS-90 via a variable temperature heatpipe blackbody (773 K ...1235 K) and at a gold fixed-point blackbody radiator (1337.33 K).

  17. Rheumatoid lung disease

    MedlinePlus

    Lung disease - rheumatoid arthritis; Rheumatoid nodules; Rheumatoid lung ... Lung problems are common in rheumatoid arthritis. They often cause no symptoms. The cause of lung disease associated with rheumatoid arthritis is unknown. Sometimes, the medicines used to ...

  18. Lung cancer - small cell

    MedlinePlus

    Cancer - lung - small cell; Small cell lung cancer; SCLC ... About 15% of all lung cancer cases are SCLC. Small cell lung cancer is slightly more common in men than women. Almost all cases of SCLC are ...

  19. Lung Nodules: Overview

    MedlinePlus

    ... Research & Science Education & Training Home Conditions Lung Nodules Lung Nodules Make an Appointment Find a Doctor Ask ... Kern, MD (June 01, 2016) What is a lung nodule? A lung nodule is also called a ...

  20. Prenatal diagnosis, 3-D virtual rendering and lung sparing surgery by ligasure device in a baby with “CCAM and intralobar pulmonary sequestration”

    PubMed Central

    Molinaro, Francesco; Angotti, Rossella; Di Crescenzo, Vincenzo Giuseppe; Cortese, Antonio; Messina, Mario

    2016-01-01

    Abstract Congenital cystic lung lesions are a rare but clinically significant group of anomalies, including congenital cystic adenomatoid malformation (CCAM), pulmonary sequestration, congenital lobar emphysema (CLE) and bronchogenic cysts. Despite the knowledge of these lesions increasing in the last years, some aspects are still debated and controversial. The diagnosis is certainly one aspect which underwent many changes in the last 15 years due to the improvement of antenatal scan and the introduction of 3-D reconstruction techniques. As it is known, a prompt diagnosis has an essential role in the management of these children. The new imaging studies as 3D Volume rendering system are the focus of this paper. We describe our preliminary experience in a case of hybrid lung lesion, which we approached by thoracoscopy after a preoperative study with 3D VR reconstruction. Our final balance is absolutely positive. PMID:28352794

  1. Furrier's lung

    PubMed Central

    Pimentel, J. Cortez

    1970-01-01

    As is known, the inhalation of animal hairs can provoke immunological reactions in the respiratory tract affecting the naso-tracheo-bronchial sector and giving rise to asthma-like syndromes. Another form of disease, found in furriers with long exposure to `hair dust', is described. It is characterized by a granulomatous interstitial pneumonia, of the tuberculoid type, very similar to that described in other diseases related to the inhalation of organic dusts, both vegetable and animal, such as `farmer's lung' and `bird fancier's lung'. This new disease—which we experimentally reproduced—can be diagnosed from the occupational history together with the finding on lung biopsy of hair shafts within granulomatous lesions (birefringence and histo-chemical reactions). As in other diseases of this type, a host factor of probable immunological nature is suggested. Attention is drawn to the need to protect workers in the furrier's trade. Images PMID:5484998

  2. Age-specific absolute and relative organ weight distributions for B6C3F1 mice.

    PubMed

    Marino, Dale J

    2012-01-01

    The B6C3F1 mouse is the standard mouse strain used in toxicology studies conducted by the National Cancer Institute (NCI) and the National Toxicology Program (NTP). While numerous reports have been published on growth, survival, and tumor incidence, no overall compilation of organ weight data is available. Importantly, organ weight change is an endpoint used by regulatory agencies to develop toxicity reference values (TRVs) for use in human health risk assessments. Furthermore, physiologically based pharmacokinetic (PBPK) models, which utilize relative organ weights, are increasingly being used to develop TRVs. Therefore, all available absolute and relative organ weight data for untreated control B6C3F1 mice were collected from NCI/NTP studies in order to develop age-specific distributions. Results show that organ weights were collected more frequently in NCI/NTP studies at 2-wk (60 studies), 3-mo (147 studies), and 15-mo (40 studies) intervals than at other intervals, and more frequently from feeding and inhalation than drinking water studies. Liver, right kidney, lung, heart, thymus, and brain weights were most frequently collected. From the collected data, the mean and standard deviation for absolute and relative organ weights were calculated. Results show age-related increases in absolute liver, right kidney, lung, and heart weights and relatively stable brain and right testis weights. The results suggest a general variability trend in absolute organ weights of brain < right testis < right kidney < heart < liver < lung < spleen < thymus. This report describes the results of this effort.

  3. Effect of induction chemotherapy on estimated risk of radiation pneumonitis in bulky non–small cell lung cancer

    SciTech Connect

    Amin, Neha P.; Miften, Moyed; Thornton, Dale; Ryan, Nicole; Kavanagh, Brian; Gaspar, Laurie E

    2013-10-01

    Patients with bulky non–small cell lung cancer (NSCLC) may be at a high risk for radiation pneumonitis (RP) if treated with up-front concurrent chemoradiation. There is limited information about the effect of induction chemotherapy on the volume of normal lung subsequently irradiated. This study aims to estimate the reduction in risk of RP in patients with NSCLC after receiving induction chemotherapy. Between 2004 and 2009, 25 patients with Stage IV NSCLC were treated with chemotherapy alone (no surgery or radiation therapy [RT]) and had computed tomography (CT) scans before and after 2 cycles of chemotherapy. Simulated RT plans were created for the prechemotherapy and postchemotherapy scans so as to deliver 60 Gy to the thoracic disease in patients who had either a >20% volumetric increase or decrease in gross tumor volume (GTV) from chemotherapy. The prechemotherapy and postchemotherapy scans were analyzed to compare the percentage of lung volume receiving≥20 Gy (V20), mean lung dose (MLD), and normal tissue complication probability (NTCP). Eight patients (32%) had a GTV reduction >20%, 2 (8%) had GTV increase >20%, and 15 (60%) had stable GTV. In the 8 responders, there was an absolute median GTV decrease of 88.1 cc (7.3 to 351.6 cc) or a 48% (20% to 62%) relative reduction in tumor burden. One had >20% tumor progression during chemotherapy, yet had an improvement in dosimetric parameters postchemotherapy. Among these 9 patients, the median decrease in V20, MLD, and NTCP was 2.6% (p<0.01), 2.1 Gy (p<0.01), and 5.6% (p<0.01), respectively. Less than one-third of patients with NSCLC obtain >20% volumetric tumor reduction from chemotherapy alone. Even with that amount of volumetric reduction, the 5% reduced risk of RP was only modest and did not convert previously ineligible patients to safely receive definitive thoracic RT.

  4. Prospective study evaluating the use of IV contrast on IMRT treatment planning for lung cancer

    SciTech Connect

    Li, Hua Bottani, Beth; DeWees, Todd; Michalski, Jeff M.; Mutic, Sasa; Bradley, Jeffrey D.; Robinson, Clifford G.; Low, Daniel A.

    2014-03-15

    Purpose: To investigate the impact of exclusively using intravenous (IV) contrast x-ray computed tomography (CT) scans on lung cancer intensity-modulated radiation therapy (IMRT) treatment planning. Methods: Eight patients with lung cancer (one small cell, seven nonsmall cell) scheduled to receive IMRT consented to acquisition of simulation CT scans with and without IV contrast. Clinical treatment plans optimized on the noncontrast scans were recomputed on contrast scans and dose coverage was compared, along with the γ passing rates. Results: IV contrast enhanced scans provided better target and critical structure conspicuity than the noncontrast scans. Using noncontrast scan as a reference, the median absolute/relative differences in mean, maximum, and minimum doses to the planning target volume (PTV) were −4.5 cGy/−0.09%, 41.1 cGy/0.62%, and −19.7 cGy/−0.50%, respectively. Regarding organs-at-risk (OARs), the median absolute/relative differences of maximum dose to heart was −13.3 cGy/−0.32%, to esophagus was −63.4 cGy/−0.89%, and to spinal cord was −16.3 cGy/−0.46%. The median heart region of interest CT Hounsfield Unit (HU) number difference between noncontrast and contrast scans was 136.4 HU (range, 94.2–161.8 HU). Subjectively, the regions with absolute dose differences greater than 3% of the prescription dose were small and typically located at the patient periphery and/or at the beam edges. The median γ passing rate was 0.9981 (range, 0.9654–0.9999) using 3% absolute dose difference/3 mm distance-to-agreement criteria. Overall, all evaluated cases were found to be clinically equivalent. Conclusions: PTV and OARs dose differences between noncontrast and contrast scans appear to be minimal for lung cancer patients undergoing IMRT. Using IV contrast scans as the primary simulation dataset could increase treatment planning efficiency and accuracy by avoiding unnecessary scans, manually region overriding, and planning errors caused by

  5. [Humidifier lung].

    PubMed

    Gerber, P; de Haller, R; Pyrozynski, W J; Sturzenegger, E R; Brändli, O

    1981-02-07

    Breathing air from a humidifier or an air conditioning unit contaminated by various microorganisms can cause an acute lung disease involving fever, cough and dyspnea, termed "humidifier fever". This type of hypersensitivity pneumonitis was first described in 1959 by PESTALOZZI in the Swiss literature and subsequently by BANASZAK et al. in the Anglo-American. Here a chronic form of this disease which led to pulmonary fibrosis is described: A 37-year-old woman who works in a cheese shop presented with dyspnea which had been progressive over two years, weight loss, a diffuse reticular pattern radiographically and a severe restrictive defect in lung function tests. Open lung biopsy revealed chronic interstitial and alveolar inflammation with non-caseating granulomas and fibrotic changes. Circulating immune complexes and precipitins against the contaminated humidifier water and cheese mites were found, but no antibodies suggesting legionnaires' disease. Two out of five otherwise healthy employees of this cheese shop, where a new humidifying system had been installed 7 years earlier, also had precipitins against the contaminated water from the humidifier and the cheese mites. Despite ending of exposure and longterm steroid and immunosuppressive therapy, the signs and symptoms of pulmonary fibrosis persisted. Contrary to the acute disease, this chronic form is termed "humidifier lung". The importance is stressed of investigating the possibility of exposure to contaminated humidifiers or air conditioning units in all cases of newly detected pulmonary fibrosis.

  6. Lung surgery

    MedlinePlus

    ... are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also be used. Lung surgery using a ... clot from the pulmonary artery ( pulmonary embolism ) Treat complications of tuberculosis Video-assisted thoracoscopic surgery can be used to treat many of these ...

  7. From Hubble's NGSL to Absolute Fluxes

    NASA Technical Reports Server (NTRS)

    Heap, Sara R.; Lindler, Don

    2012-01-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R-l000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18-1.00 microns. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsll. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We are therefore developing an observing procedure that should yield fluxes with uncertainties less than 1 % and will take part in an HST proposal to observe up to 15 stars using this new procedure.

  8. Consistent thermostatistics forbids negative absolute temperatures

    NASA Astrophysics Data System (ADS)

    Dunkel, Jörn; Hilbert, Stefan

    2014-01-01

    Over the past 60 years, a considerable number of theories and experiments have claimed the existence of negative absolute temperature in spin systems and ultracold quantum gases. This has led to speculation that ultracold gases may be dark-energy analogues and also suggests the feasibility of heat engines with efficiencies larger than one. Here, we prove that all previous negative temperature claims and their implications are invalid as they arise from the use of an entropy definition that is inconsistent both mathematically and thermodynamically. We show that the underlying conceptual deficiencies can be overcome if one adopts a microcanonical entropy functional originally derived by Gibbs. The resulting thermodynamic framework is self-consistent and implies that absolute temperature remains positive even for systems with a bounded spectrum. In addition, we propose a minimal quantum thermometer that can be implemented with available experimental techniques.

  9. Absolute measurement of length with nanometric resolution

    NASA Astrophysics Data System (ADS)

    Apostol, D.; Garoi, F.; Timcu, A.; Damian, V.; Logofatu, P. C.; Nascov, V.

    2005-08-01

    Laser interferometer displacement measuring transducers have a well-defined traceability route to the definition of the meter. The laser interferometer is de-facto length scale for applications in micro and nano technologies. However their physical unit -half lambda is too large for nanometric resolution. Fringe interpolation-usual technique to improve the resolution-lack of reproducibility could be avoided using the principles of absolute distance measurement. Absolute distance refers to the use of interferometric techniques for determining the position of an object without the necessity of measuring continuous displacements between points. The interference pattern as produced by the interference of two point-like coherent sources is fitted to a geometric model so as to determine the longitudinal location of the target by minimizing least square errors. The longitudinal coordinate of the target was measured with accuracy better than 1 nm, for a target position range of 0.4μm.

  10. Asteroid absolute magnitudes and slope parameters

    NASA Technical Reports Server (NTRS)

    Tedesco, Edward F.

    1991-01-01

    A new listing of absolute magnitudes (H) and slope parameters (G) has been created and published in the Minor Planet Circulars; this same listing will appear in the 1992 Ephemerides of Minor Planets. Unlike previous listings, the values of the current list were derived from fits of data at the V band. All observations were reduced in the same fashion using, where appropriate, a single basis default value of 0.15 for the slope parameter. Distances and phase angles were computed for each observation. The data for 113 asteroids was of sufficiently high quality to permit derivation of their H and G. These improved absolute magnitudes and slope parameters will be used to deduce the most reliable bias-corrected asteroid size-frequency distribution yet made.

  11. Computer processing of spectrograms for absolute intensities.

    PubMed

    Guttman, A; Golden, J; Galbraith, H J

    1967-09-01

    A computer program was developed to process photographically recorded spectra for absolute intensity. Test and calibration films are subjected to densitometric scans that provide digitally recorded densities on magnetic tapes. The nonlinear calibration data are fitted by least-squares cubic polynomials to yield a good approximation to the monochromatic H&D curves for commonly used emulsions (2475 recording film, Royal-X, Tri-X, 4-X). Several test cases were made. Results of these cases show that the machine processed absolute intensities are accurate to within 15%o. Arbitrarily raising the sensitivity threshold by 0.1 density units above gross fog yields cubic polynomial fits to the H&D curves that are radiometrically accurate within 10%. In addition, curves of gamma vs wavelength for 2475, Tri-X, and 4-X emulsions were made. These data show slight evidence of the photographic Purkinje effect in the 2475 emulsion.

  12. An absolute measure for a key currency

    NASA Astrophysics Data System (ADS)

    Oya, Shunsuke; Aihara, Kazuyuki; Hirata, Yoshito

    It is generally considered that the US dollar and the euro are the key currencies in the world and in Europe, respectively. However, there is no absolute general measure for a key currency. Here, we investigate the 24-hour periodicity of foreign exchange markets using a recurrence plot, and define an absolute measure for a key currency based on the strength of the periodicity. Moreover, we analyze the time evolution of this measure. The results show that the credibility of the US dollar has not decreased significantly since the Lehman shock, when the Lehman Brothers bankrupted and influenced the economic markets, and has increased even relatively better than that of the euro and that of the Japanese yen.

  13. Probing absolute spin polarization at the nanoscale.

    PubMed

    Eltschka, Matthias; Jäck, Berthold; Assig, Maximilian; Kondrashov, Oleg V; Skvortsov, Mikhail A; Etzkorn, Markus; Ast, Christian R; Kern, Klaus

    2014-12-10

    Probing absolute values of spin polarization at the nanoscale offers insight into the fundamental mechanisms of spin-dependent transport. Employing the Zeeman splitting in superconducting tips (Meservey-Tedrow-Fulde effect), we introduce a novel spin-polarized scanning tunneling microscopy that combines the probing capability of the absolute values of spin polarization with precise control at the atomic scale. We utilize our novel approach to measure the locally resolved spin polarization of magnetic Co nanoislands on Cu(111). We find that the spin polarization is enhanced by 65% when increasing the width of the tunnel barrier by only 2.3 Å due to the different decay of the electron orbitals into vacuum.

  14. Absolute and relative dosimetry for ELIMED

    NASA Astrophysics Data System (ADS)

    Cirrone, G. A. P.; Cuttone, G.; Candiano, G.; Carpinelli, M.; Leonora, E.; Lo Presti, D.; Musumarra, A.; Pisciotta, P.; Raffaele, L.; Randazzo, N.; Romano, F.; Schillaci, F.; Scuderi, V.; Tramontana, A.; Cirio, R.; Marchetto, F.; Sacchi, R.; Giordanengo, S.; Monaco, V.

    2013-07-01

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  15. REDUCTION IN INSPIRATORY FLOW ATTENUATES IL-8 RELEASE AND MAPK ACTIVATION OF LUNG OVERSTRETCH

    EPA Science Inventory

    Lung overstretch involves mechanical factors, including large tidal volumes (VT), which induce inflammatory responses. The current authors hypothesised that inspiratory flow contributes to ventilator-induced inflammation. Buffer-perfused rabbit lungs were ventilated for 2 h with ...

  16. Silicon Absolute X-Ray Detectors

    SciTech Connect

    Seely, John F.; Korde, Raj; Sprunck, Jacob; Medjoubi, Kadda; Hustache, Stephanie

    2010-06-23

    The responsivity of silicon photodiodes having no loss in the entrance window, measured using synchrotron radiation in the 1.75 to 60 keV range, was compared to the responsivity calculated using the silicon thickness measured using near-infrared light. The measured and calculated responsivities agree with an average difference of 1.3%. This enables their use as absolute x-ray detectors.

  17. Negative absolute temperature for mobile particles

    NASA Astrophysics Data System (ADS)

    Braun, Simon; Ronzheimer, Philipp; Schreiber, Michael; Hodgman, Sean; Bloch, Immanuel; Schneider, Ulrich

    2013-05-01

    Absolute temperature is usually bound to be strictly positive. However, negative absolute temperature states, where the occupation probability of states increases with their energy, are possible in systems with an upper energy bound. So far, such states have only been demonstrated in localized spin systems with finite, discrete spectra. We realized a negative absolute temperature state for motional degrees of freedom with ultracold bosonic 39K atoms in an optical lattice, by implementing the attractive Bose-Hubbard Hamiltonian. This new state strikingly revealed itself by a quasimomentum distribution that is peaked at maximum kinetic energy. The measured kinetic energy distribution and the extracted negative temperature indicate that the ensemble is close to degeneracy, with coherence over several lattice sites. The state is as stable as a corresponding positive temperature state: The negative temperature stabilizes the system against mean-field collapse driven by negative pressure. Negative temperatures open up new parameter regimes for cold atoms, enabling fundamentally new many-body states. Additionally, they give rise to several counterintuitive effects such as heat engines with above unity efficiency.

  18. Measurement of absolute gravity acceleration in Firenze

    NASA Astrophysics Data System (ADS)

    de Angelis, M.; Greco, F.; Pistorio, A.; Poli, N.; Prevedelli, M.; Saccorotti, G.; Sorrentino, F.; Tino, G. M.

    2011-01-01

    This paper reports the results from the accurate measurement of the acceleration of gravity g taken at two separate premises in the Polo Scientifico of the University of Firenze (Italy). In these laboratories, two separate experiments aiming at measuring the Newtonian constant and testing the Newtonian law at short distances are in progress. Both experiments require an independent knowledge on the local value of g. The only available datum, pertaining to the italian zero-order gravity network, was taken more than 20 years ago at a distance of more than 60 km from the study site. Gravity measurements were conducted using an FG5 absolute gravimeter, and accompanied by seismic recordings for evaluating the noise condition at the site. The absolute accelerations of gravity at the two laboratories are (980 492 160.6 ± 4.0) μGal and (980 492 048.3 ± 3.0) μGal for the European Laboratory for Non-Linear Spectroscopy (LENS) and Dipartimento di Fisica e Astronomia, respectively. Other than for the two referenced experiments, the data here presented will serve as a benchmark for any future study requiring an accurate knowledge of the absolute value of the acceleration of gravity in the study region.

  19. System for absolute measurements by interferometric sensors

    NASA Astrophysics Data System (ADS)

    Norton, Douglas A.

    1993-03-01

    The most common problem of interferometric sensors is their inability to measure absolute path imbalance. Presented in this paper is a signal processing system that gives absolute, unambiguous reading of optical path difference for almost any style of interferometric sensor. Key components are a wide band (incoherent) optical source, a polychromator, and FFT electronics. Advantages include no moving parts in the signal processor, no active components at the sensor location, and the use of standard single mode fiber for sensor illumination and signal transmission. Actual absolute path imbalance of the interferometer is determined without using fringe counting or other inferential techniques. The polychromator extracts the interference information that occurs at each discrete wavelength within the spectral band of the optical source. The signal processing consists of analog and digital filtering, Fast Fourier analysis, and a peak detection and interpolation algorithm. This system was originally designed for use in a remote pressure sensing application that employed a totally passive fiber optic interferometer. A performance qualification was made using a Fabry-Perot interferometer and a commercially available laser interferometer to measure the reference displacement.

  20. Chemical composition of French mimosa absolute oil.

    PubMed

    Perriot, Rodolphe; Breme, Katharina; Meierhenrich, Uwe J; Carenini, Elise; Ferrando, Georges; Baldovini, Nicolas

    2010-02-10

    Since decades mimosa (Acacia dealbata) absolute oil has been used in the flavor and perfume industry. Today, it finds an application in over 80 perfumes, and its worldwide industrial production is estimated five tons per year. Here we report on the chemical composition of French mimosa absolute oil. Straight-chain analogues from C6 to C26 with different functional groups (hydrocarbons, esters, aldehydes, diethyl acetals, alcohols, and ketones) were identified in the volatile fraction. Most of them are long-chain molecules: (Z)-heptadec-8-ene, heptadecane, nonadecane, and palmitic acid are the most abundant, and constituents such as 2-phenethyl alcohol, methyl anisate, and ethyl palmitate are present in smaller amounts. The heavier constituents were mainly triterpenoids such as lupenone and lupeol, which were identified as two of the main components. (Z)-Heptadec-8-ene, lupenone, and lupeol were quantified by GC-MS in SIM mode using external standards and represents 6%, 20%, and 7.8% (w/w) of the absolute oil. Moreover, odorant compounds were extracted by SPME and analyzed by GC-sniffing leading to the perception of 57 odorant zones, of which 37 compounds were identified by their odorant description, mass spectrum, retention index, and injection of the reference compound.

  1. Constrained Least Absolute Deviation Neural Networks

    PubMed Central

    Wang, Zhishun; Peterson, Bradley S.

    2008-01-01

    It is well known that least absolute deviation (LAD) criterion or L1-norm used for estimation of parameters is characterized by robustness, i.e., the estimated parameters are totally resistant (insensitive) to large changes in the sampled data. This is an extremely useful feature, especially, when the sampled data are known to be contaminated by occasionally occurring outliers or by spiky noise. In our previous works, we have proposed the least absolute deviation neural network (LADNN) to solve unconstrained LAD problems. The theoretical proofs and numerical simulations have shown that the LADNN is Lyapunov-stable and it can globally converge to the exact solution to a given unconstrained LAD problem. We have also demonstrated its excellent application value in time-delay estimation. More generally, a practical LAD application problem may contain some linear constraints, such as a set of equalities and/or inequalities, which is called constrained LAD problem, whereas the unconstrained LAD can be considered as a special form of the constrained LAD. In this paper, we present a new neural network called constrained least absolute deviation neural network (CLADNN) to solve general constrained LAD problems. Theoretical proofs and numerical simulations demonstrate that the proposed CLADNN is Lyapunov stable and globally converges to the exact solution to a given constrained LAD problem, independent of initial values. The numerical simulations have also illustrated that the proposed CLADNN can be used to robustly estimate parameters for nonlinear curve fitting, which is extensively used in signal and image processing. PMID:18269958

  2. Lung retention of cerium in humans.

    PubMed Central

    Pairon, J C; Roos, F; Iwatsubo, Y; Janson, X; Billon-Galland, M A; Bignon, J; Brochard, P

    1994-01-01

    A retrospective study was conducted to evaluate lung retention of particles containing cerium in subjects with and without previous occupational exposure to mineral dusts. Analytical transmission electron microscopy was performed on 459 samples of bronchoalveolar lavage (BAL) fluid and 75 samples of lung tissue. Study of the distribution of mineralogical species in human samples showed that particles containing cerium were encountered in less than 10% of subjects. The proportion of subjects with particles containing cerium in their biological samples was not different between controls and subjects with previous occupational exposure to fibrous or nonfibrous mineral dusts. This was considered as the background level of lung retention of cerium in the general population. By contrast, determination of the absolute concentration of particles containing cerium in BAL fluid and lung tissue samples showed that 1.2% (from BAL fluid) and 1.5% (from lung tissue) of subjects with previous exposure to mineral particles had high lung retention of particles containing cerium. This study is believed to be the first one in which lung retention of cerium was estimated in the general population. PMID:8130849

  3. Surfactant Delivery into the Lung

    NASA Astrophysics Data System (ADS)

    Grotberg, James; Filoche, Marcel

    2014-11-01

    We have developed a multiscale, compartmentalized model of surfactant and liquid delivery into the lung. Assuming liquid plug propagation, the airway compartment accounts for the plug's volume deposition (coating) on the airway wall, while the bifurcation compartment accounts for plug splitting from the parent airway to the two daughter airways. Generally the split is unequal due to gravity and geometry effects. Both the deposition ratio RD (deposition volume/airway volume), and the splitting ratio, RS, of the daughters volumes are solved independently from one another. Then they are used in a 3D airway network geometry to achieve the distribution of delivery into the lung. The airway geometry is selected for neonatal as well as adult applications, and can be advanced from symmetric, to stochastically asymmetric, to personalized. RD depends primarily on the capillary number, Ca, while RS depends on Ca, the Reynolds number, Re, the Bond number, Bo, the dose volume, VD, and the branch angles. The model predicts the distribution of coating on the airway walls and the remaining plug volume delivered to the alveolar region at the end of the tree. Using this model, we are able to simulate and test various delivery protocols, in order to optimize delivery and improve the respiratory function.

  4. Lung transplantation in adults and children: putting lung function into perspective.

    PubMed

    Thompson, Bruce Robert; Westall, Glen Philip; Paraskeva, Miranda; Snell, Gregory Ian

    2014-11-01

    The number of lung transplants performed globally continues to increase year after year. Despite this growing experience, long-term outcomes following lung transplantation continue to fall far short of that described in other solid-organ transplant settings. Chronic lung allograft dysfunction (CLAD) remains common and is the end result of exposure to a multitude of potentially injurious insults that include alloreactivity and infection among others. Central to any description of the clinical performance of the transplanted lung is an assessment of its physiology by pulmonary function testing. Spirometry and the evaluation of forced expiratory volume in 1 s and forced vital capacity, remain core indices that are measured as part of routine clinical follow-up. Spirometry, while reproducible in detecting lung allograft dysfunction, lacks specificity in differentiating the different complications of lung transplantation such as rejection, infection and bronchiolitis obliterans. However, interpretation of spirometry is central to defining the different 'chronic rejection' phenotypes. It is becoming apparent that the maximal lung function achieved following transplantation, as measured by spirometry, is influenced by a number of donor and recipient factors as well as the type of surgery performed (single vs double vs lobar lung transplant). In this review, we discuss the wide range of variables that need to be considered when interpreting lung function testing in lung transplant recipients. Finally, we review a number of novel measurements of pulmonary function that may in the future serve as better biomarkers to detect and diagnose the cause of the failing lung allograft.

  5. American Cancer Society Lung Cancer Screening Guidelines

    PubMed Central

    Wender, Richard; Fontham, Elizabeth T. H.; Barrera, Ermilo; Colditz, Graham A.; Church, Timothy R.; Ettinger, David S.; Etzioni, Ruth; Flowers, Christopher R.; Gazelle, G. Scott; Kelsey, Douglas K.; LaMonte, Samuel J.; Michaelson, James S.; Oeffinger, Kevin C.; Shih, Ya-Chen Tina; Sullivan, Daniel C.; Travis, William; Walter, Louise; Wolf, Andrew M. D.; Brawley, Otis W.; Smith, Robert A.

    2013-01-01

    Findings from the National Cancer Institute’s National Lung Screening Trial established that lung cancer mortality in specific high-risk groups can be reduced by annual screening with low-dose computed tomography. These findings indicate that the adoption of lung cancer screening could save many lives. Based on the results of the National Lung Screening Trial, the American Cancer Society is issuing an initial guideline for lung cancer screening. This guideline recommends that clinicians with access to high-volume, high-quality lung cancer screening and treatment centers should initiate a discussion about screening with apparently healthy patients aged 55 years to 74 years who have at least a 30-pack-year smoking history and who currently smoke or have quit within the past 15 years. A process of informed and shared decision-making with a clinician related to the potential benefits, limitations, and harms associated with screening for lung cancer with low-dose computed tomography should occur before any decision is made to initiate lung cancer screening. Smoking cessation counseling remains a high priority for clinical attention in discussions with current smokers, who should be informed of their continuing risk of lung cancer. Screening should not be viewed as an alternative to smoking cessation. PMID:23315954

  6. American Cancer Society lung cancer screening guidelines.

    PubMed

    Wender, Richard; Fontham, Elizabeth T H; Barrera, Ermilo; Colditz, Graham A; Church, Timothy R; Ettinger, David S; Etzioni, Ruth; Flowers, Christopher R; Gazelle, G Scott; Kelsey, Douglas K; LaMonte, Samuel J; Michaelson, James S; Oeffinger, Kevin C; Shih, Ya-Chen Tina; Sullivan, Daniel C; Travis, William; Walter, Louise; Wolf, Andrew M D; Brawley, Otis W; Smith, Robert A

    2013-01-01

    Findings from the National Cancer Institute's National Lung Screening Trial established that lung cancer mortality in specific high-risk groups can be reduced by annual screening with low-dose computed tomography. These findings indicate that the adoption of lung cancer screening could save many lives. Based on the results of the National Lung Screening Trial, the American Cancer Society is issuing an initial guideline for lung cancer screening. This guideline recommends that clinicians with access to high-volume, high-quality lung cancer screening and treatment centers should initiate a discussion about screening with apparently healthy patients aged 55 years to 74 years who have at least a 30-pack-year smoking history and who currently smoke or have quit within the past 15 years. A process of informed and shared decision-making with a clinician related to the potential benefits, limitations, and harms associated with screening for lung cancer with low-dose computed tomography should occur before any decision is made to initiate lung cancer screening. Smoking cessation counseling remains a high priority for clinical attention in discussions with current smokers, who should be informed of their continuing risk of lung cancer. Screening should not be viewed as an alternative to smoking cessation.

  7. Type II congenital pulmonary airway malformation in an esophageal lung

    PubMed Central

    Martínez-Martínez, Blanca Estela; Furuya, María Elena Yuriko; Martínez-Muñiz, Irma; Vargas, Mario H; Flores-Salgado, Rosalinda

    2013-01-01

    A seven-month-old girl, born prematurely (birth weight 1000 g) from a twin pregnancy, was admitted to hospital due to recurrent pneumonia and atelectasis. She experienced cough and respiratory distress during feeding. The right hemithorax was smaller than the left, with diminished breath sounds and dullness. Chest x-rays revealed decreased lung volume and multiple radiolucent images in the right lung, as well as overdistention of the left lung. An esophagogram revealed three bronchial branches arising from the lower one-third of the esophagus, corresponding to the right lung and ending in a cul-de-sac. A diagnosis of esophageal lung was established. On bronchography, the right lung was absent and the trachea only continued into the left main bronchus. Echocardiography and angiotomography revealed agenesis of the pulmonary artery right branch. The surgical finding was an esophageal right lung, which was removed; the histopathological diagnosis was type II congenital pulmonary airway malformation in an esophageal lung. PMID:23762890

  8. Type II congenital cystic pulmonary malformation in an esophageal lung.

    PubMed

    Martínez-Martínez, Blanca E; Furuya, María Elena Yuriko; Martínez-Muñiz, Irma; Vargas, Mario H; Flores-Salgado, Rosalinda

    2013-01-01

    A seven-month-old girl, born prematurely (birth weight 1000 g) from a twin pregnancy, was admitted to hospital due to recurrent pneumonia and atelectasis. She experienced cough and respiratory distress during feeding. The right hemithorax was smaller than the left, with diminished breath sounds and dullness. Chest x-rays revealed decreased lung volume and multiple radiolucent images in the right lung, as well as overdistention of the left lung. An esophagogram revealed three bronchial branches arising from the lower one-third of the esophagus, corresponding to the right lung and ending in a cul-de-sac. A diagnosis of esophageal lung was established. On bronchography, the right lung was absent and the trachea only continued into the left main bronchus. Echocardiography and angiotomography revealed agenesis of the pulmonary artery right branch. The surgical finding was an esophageal right lung, which was removed; the histopathological diagnosis was type II congenital pulmonary airway malformation in an esophageal lung.

  9. Clock time is absolute and universal

    NASA Astrophysics Data System (ADS)

    Shen, Xinhang

    2015-09-01

    A critical error is found in the Special Theory of Relativity (STR): mixing up the concepts of the STR abstract time of a reference frame and the displayed time of a physical clock, which leads to use the properties of the abstract time to predict time dilation on physical clocks and all other physical processes. Actually, a clock can never directly measure the abstract time, but can only record the result of a physical process during a period of the abstract time such as the number of cycles of oscillation which is the multiplication of the abstract time and the frequency of oscillation. After Lorentz Transformation, the abstract time of a reference frame expands by a factor gamma, but the frequency of a clock decreases by the same factor gamma, and the resulting multiplication i.e. the displayed time of a moving clock remains unchanged. That is, the displayed time of any physical clock is an invariant of Lorentz Transformation. The Lorentz invariance of the displayed times of clocks can further prove within the framework of STR our earth based standard physical time is absolute, universal and independent of inertial reference frames as confirmed by both the physical fact of the universal synchronization of clocks on the GPS satellites and clocks on the earth, and the theoretical existence of the absolute and universal Galilean time in STR which has proved that time dilation and space contraction are pure illusions of STR. The existence of the absolute and universal time in STR has directly denied that the reference frame dependent abstract time of STR is the physical time, and therefore, STR is wrong and all its predictions can never happen in the physical world.

  10. Absolute Radiometric Calibration of EUNIS-06

    NASA Technical Reports Server (NTRS)

    Thomas, R. J.; Rabin, D. M.; Kent, B. J.; Paustian, W.

    2007-01-01

    The Extreme-Ultraviolet Normal-Incidence Spectrometer (EUNIS) is a soundingrocket payload that obtains imaged high-resolution spectra of individual solar features, providing information about the Sun's corona and upper transition region. Shortly after its successful initial flight last year, a complete end-to-end calibration was carried out to determine the instrument's absolute radiometric response over its Longwave bandpass of 300 - 370A. The measurements were done at the Rutherford-Appleton Laboratory (RAL) in England, using the same vacuum facility and EUV radiation source used in the pre-flight calibrations of both SOHO/CDS and Hinode/EIS, as well as in three post-flight calibrations of our SERTS sounding rocket payload, the precursor to EUNIS. The unique radiation source provided by the Physikalisch-Technische Bundesanstalt (PTB) had been calibrated to an absolute accuracy of 7% (l-sigma) at 12 wavelengths covering our bandpass directly against the Berlin electron storage ring BESSY, which is itself a primary radiometric source standard. Scans of the EUNIS aperture were made to determine the instrument's absolute spectral sensitivity to +- 25%, considering all sources of error, and demonstrate that EUNIS-06 was the most sensitive solar E W spectrometer yet flown. The results will be matched against prior calibrations which relied on combining measurements of individual optical components, and on comparisons with theoretically predicted 'insensitive' line ratios. Coordinated observations were made during the EUNIS-06 flight by SOHO/CDS and EIT that will allow re-calibrations of those instruments as well. In addition, future EUNIS flights will provide similar calibration updates for TRACE, Hinode/EIS, and STEREO/SECCHI/EUVI.

  11. Achieving Climate Change Absolute Accuracy in Orbit

    NASA Technical Reports Server (NTRS)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; Bowman, K.; Brindley, H.; Butler, J. J.; Collins, W.; Dykema, J. A.; Doelling, D. R.; Feldman, D. R.; Fox, N.; Huang, X.; Holz, R.; Huang, Y.; Jennings, D.; Jin, Z.; Johnson, D. G.; Jucks, K.; Kato, S.; Kratz, D. P.; Liu, X.; Lukashin, C.; Mannucci, A. J.; Phojanamongkolkij, N.; Roithmayr, C. M.; Sandford, S.; Taylor, P. C.; Xiong, X.

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  12. Toward a clinical application of ex situ boron neutron capture therapy for lung tumors at the RA-3 reactor in Argentina

    SciTech Connect

    Farías, R. O.; Trivillin, V. A.; Portu, A. M.; Schwint, A. E.; González, S. J.; Garabalino, M. A.; Monti Hughes, A.; Pozzi, E. C. C.; Thorp, S. I.; Curotto, P.; Miller, M. E.; Santa Cruz, G. A.; Saint Martin, G.; Ferraris, S.; Santa María, J.; Rovati, O.; Lange, F.; Bortolussi, S.; Altieri, S.

    2015-07-15

    Purpose: Many types of lung tumors have a very poor prognosis due to their spread in the whole organ volume. The fact that boron neutron capture therapy (BNCT) would allow for selective targeting of all the nodules regardless of their position, prompted a preclinical feasibility study of ex situ BNCT at the thermal neutron facility of RA-3 reactor in the province of Buenos Aires, Argentina. (L)-4p-dihydroxy-borylphenylalanine fructose complex (BPA-F) biodistribution studies in an adult sheep model and computational dosimetry for a human explanted lung were performed to evaluate the feasibility and the therapeutic potential of ex situ BNCT. Methods: Two kinds of boron biodistribution studies were carried out in the healthy sheep: a set of pharmacokinetic studies without lung excision, and a set that consisted of evaluation of boron concentration in the explanted and perfused lung. In order to assess the feasibility of the clinical application of ex situ BNCT at RA-3, a case of multiple lung metastases was analyzed. A detailed computational representation of the geometry of the lung was built based on a real collapsed human lung. Dosimetric calculations and dose limiting considerations were based on the experimental results from the adult sheep, and on the most suitable information published in the literature. In addition, a workable treatment plan was considered to assess the clinical application in a realistic scenario. Results: Concentration-time profiles for the normal sheep showed that the boron kinetics in blood, lung, and skin would adequately represent the boron behavior and absolute uptake expected in human tissues. Results strongly suggest that the distribution of the boron compound is spatially homogeneous in the lung. A constant lung-to-blood ratio of 1.3 ± 0.1 was observed from 80 min after the end of BPA-F infusion. The fact that this ratio remains constant during time would allow the blood boron concentration to be used as a surrogate and indirect

  13. Brownian motion: Absolute negative particle mobility

    NASA Astrophysics Data System (ADS)

    Ros, Alexandra; Eichhorn, Ralf; Regtmeier, Jan; Duong, Thanh Tu; Reimann, Peter; Anselmetti, Dario

    2005-08-01

    Noise effects in technological applications, far from being a nuisance, can be exploited with advantage - for example, unavoidable thermal fluctuations have found application in the transport and sorting of colloidal particles and biomolecules. Here we use a microfluidic system to demonstrate a paradoxical migration mechanism in which particles always move in a direction opposite to the net acting force (`absolute negative mobility') as a result of an interplay between thermal noise, a periodic and symmetric microstructure, and a biased alternating-current electric field. This counterintuitive phenomenon could be used for bioanalytical purposes, for example in the separation and fractionation of colloids, biological molecules and cells.

  14. Arbitrary segments of absolute negative mobility

    NASA Astrophysics Data System (ADS)

    Chen, Ruyin; Nie, Linru; Chen, Chongyang; Wang, Chaojie

    2017-01-01

    In previous research work, investigators have reported only one or two segments of absolute negative mobility (ANM) in a periodic potential. In fact, many segments of ANM also occur in the system considered here. We investigate transport of an inertial particle in a gating ratchet periodic potential subjected to a constant bias force. Our numerical results show that its mean velocity can decrease with the bias force increasing, i.e. ANM phenomenon. Furthermore, the ANM can take place arbitrary segments, even up to more than thirty. Intrinsic physical mechanism and conditions for arbitrary segments of ANM to occur are discussed in detail.

  15. Absolute quantification of myocardial blood flow.

    PubMed

    Yoshinaga, Keiichiro; Manabe, Osamu; Tamaki, Nagara

    2016-07-21

    With the increasing availability of positron emission tomography (PET) myocardial perfusion imaging, the absolute quantification of myocardial blood flow (MBF) has become popular in clinical settings. Quantitative MBF provides an important additional diagnostic or prognostic information over conventional visual assessment. The success of MBF quantification using PET/computed tomography (CT) has increased the demand for this quantitative diagnostic approach to be more accessible. In this regard, MBF quantification approaches have been developed using several other diagnostic imaging modalities including single-photon emission computed tomography, CT, and cardiac magnetic resonance. This review will address the clinical aspects of PET MBF quantification and the new approaches to MBF quantification.

  16. An absolute radius scale for Saturn's rings

    NASA Technical Reports Server (NTRS)

    Nicholson, Philip D.; Cooke, Maren L.; Pelton, Emily

    1990-01-01

    Radio and stellar occultation observations of Saturn's rings made by the Voyager spacecraft are discussed. The data reveal systematic discrepancies of almost 10 km in some parts of the rings, limiting some of the investigations. A revised solution for Saturn's rotation pole has been proposed which removes the discrepancies between the stellar and radio occultation profiles. Corrections to previously published radii vary from -2 to -10 km for the radio occultation, and +5 to -6 km for the stellar occultation. An examination of spiral density waves in the outer A Ring supports that the revised absolute radii are in error by no more than 2 km.

  17. Absolute Rate Theories of Epigenetic Stability

    NASA Astrophysics Data System (ADS)

    Walczak, Aleksandra M.; Onuchic, Jose N.; Wolynes, Peter G.

    2006-03-01

    Spontaneous switching events in most characterized genetic switches are rare, resulting in extremely stable epigenetic properties. We show how simple arguments lead to theories of the rate of such events much like the absolute rate theory of chemical reactions corrected by a transmission factor. Both the probability of the rare cellular states that allow epigenetic escape, and the transmission factor, depend on the rates of DNA binding and unbinding events and on the rates of protein synthesis and degradation. Different mechanisms of escape from the stable attractors occur in the nonadiabatic, weakly adiabatic and strictly adiabatic regimes, characterized by the relative values of those input rates.

  18. Absolute rate theories of epigenetic stability

    NASA Astrophysics Data System (ADS)

    Walczak, Aleksandra M.; Onuchic, José N.; Wolynes, Peter G.

    2005-12-01

    Spontaneous switching events in most characterized genetic switches are rare, resulting in extremely stable epigenetic properties. We show how simple arguments lead to theories of the rate of such events much like the absolute rate theory of chemical reactions corrected by a transmission factor. Both the probability of the rare cellular states that allow epigenetic escape and the transmission factor depend on the rates of DNA binding and unbinding events and on the rates of protein synthesis and degradation. Different mechanisms of escape from the stable attractors occur in the nonadiabatic, weakly adiabatic, and strictly adiabatic regimes, characterized by the relative values of those input rates. rate theory | stochastic gene expression | gene switches

  19. Absolute method of measuring magnetic susceptibility

    USGS Publications Warehouse

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  20. Absolute Priority for a Vehicle in VANET

    NASA Astrophysics Data System (ADS)

    Shirani, Rostam; Hendessi, Faramarz; Montazeri, Mohammad Ali; Sheikh Zefreh, Mohammad

    In today's world, traffic jams waste hundreds of hours of our life. This causes many researchers try to resolve the problem with the idea of Intelligent Transportation System. For some applications like a travelling ambulance, it is important to reduce delay even for a second. In this paper, we propose a completely infrastructure-less approach for finding shortest path and controlling traffic light to provide absolute priority for an emergency vehicle. We use the idea of vehicular ad-hoc networking to reduce the imposed travelling time. Then, we simulate our proposed protocol and compare it with a centrally controlled traffic light system.

  1. Artificial lung: progress and prototypes.

    PubMed

    Zwischenberger, Brittany A; Clemson, Lindsey A; Zwischenberger, Joseph B

    2006-07-01

    Lung disease is the fourth leading cause of death (one in seven deaths) in the USA. Acute respiratory distress syndrome (ARDS) affects approximately 150,000 patients a year in the USA, and an estimated 16 million Americans are afflicted with chronic lung disease, accounting for 100,000 deaths per year. Medical management is the standard of care for initial therapy, but is limited by the progression of disease. Chronic mechanical ventilation is readily available, but is cumbersome, expensive and often requires tracheotomy with loss of upper airway defense mechanisms and normal speech. Lung transplantation is an option for less than 1100 patients per year since demand has steadily outgrown supply. For the last 15 years, the authors' group has studied ARDS in order to develop viable alternative treatments. Both extracorporeal gas exchange techniques, including extracorporeal membrane oxygenation, extracorporeal and arteriovenous CO(2) removal, and intravenous oxygenation, aim to allow for a less injurious ventilatory strategy during lung recovery while maintaining near-normal arterial blood gases, but precludes ambulation. The paracorporeal artificial lung (PAL), however, redefines the treatment of both acute and chronic respiratory failure with the goal of ambulatory total respiratory support. PAL prototypes tested on both normal sheep and the absolute lethal dose smoke/burn-induced ARDS sheep model have demonstrated initial success in achieving total gas exchange. Still, clinical trials cannot begin until bio- and hemodynamic compatibility challenges are reconciled. The PAL initial design goals are for a short-term (weeks) bridge to recovery or transplant, but eventually, for long-term support (months).

  2. Interferometric determination of the topographies of absolute sphere radii using the sphere interferometer of PTB

    NASA Astrophysics Data System (ADS)

    Bartl, Guido; Krystek, Michael; Nicolaus, Arnold; Giardini, Walter

    2010-11-01

    This paper presents a method to reconstruct the absolute shape of a sphere—i.e. a topography of radii—using the sphere interferometer of PTB in combination with a stitching approach. The method allows for the reconstruction of absolute radii instead of the relative shape deviations which result from conventional sphericity measurements. The sphere interferometer was developed for the volume determination of spherical material measures—in particular the spheres of the Avogadro project—by precise diameter measurements with an uncertainty of 1 nm or less. In the scope of the present work a procedure has been implemented that extends the applicability of the interferometer to fields where not the volume or diameter but the direction-dependent radii are of interest. The results of the reconstruction were compared quantitatively to the independent results of sphericity measurements from CSIRO.

  3. Sequential (gemcitabine/vinorelbine) and concurrent (gemcitabine) radiochemotherapy with FDG-PET-based target volume definition in locally advanced non-small cell lung cancer: first results of a phase I/II study

    PubMed Central

    Gagel, Bernd; Piroth, Marc; Pinkawa, Michael; Reinartz, Patrick; Krohn, Thomas; Kaiser, Hans J; Stanzel, Sven; Breuer, Christian; Asadpour, Branka; Schmachtenberg, Axel; Eble, Michael J

    2007-01-01

    Background The aim of the study was to determine the maximal tolerated dose (MTD) of gemcitabine every two weeks concurrent to radiotherapy, administered during an aggressive program of sequential and simultaneous radiochemotherapy for locally advanced, unresectable non-small cell lung cancer (NSCLC) and to evaluate the efficacy of this regime in a phase II study. Methods 33 patients with histologically confirmed NSCLC were enrolled in a combined radiochemotherapy protocol. 29 patients were assessable for evaluation of toxicity and tumor response. Treatment included two cycles of induction chemotherapy with gemcitabine (1200 mg/m2) and vinorelbine (30 mg/m2) at day 1, 8 and 22, 29 followed by concurrent radiotherapy (2.0 Gy/d; total dose 66.0 Gy) and chemotherapy with gemcitabine every two weeks at day 43, 57 and 71. Radiotherapy planning included [18F] fluorodeoxyglucose positron emission tomography (FDG PET) based target volume definition. 10 patients were included in the phase I study with an initial gemcitabine dose of 300 mg/m2. The dose of gemcitabine was increased in steps of 100 mg/m2 until the MTD was realized. Results MTD was defined for the patient group receiving gemcitabine 500 mg/m2 due to grade 2 (next to grade 3) esophagitis in all patients resulting in a mean body weight loss of 5 kg (SD = 1.4 kg), representing 8% of the initial weight. These patients showed persisting dysphagia 3 to 4 weeks after completing radiotherapy. In accordance with expected complications as esophagitis, dysphagia and odynophagia, we defined the MTD at this dose level, although no dose limiting toxicity (DLT) grade 3 was reached. In the phase I/II median follow-up was 15.7 months (4.1 to 42.6 months). The overall response rate after completion of therapy was 64%. The median overall survival was 19.9 (95% CI: [10.1; 29.7]) months for all eligible patients. The median disease-free survival for all patients was 8.7 (95% CI: [2.7; 14.6]) months. Conclusion After induction

  4. Systemic inflammation and lung function: A longitudinal analysis

    PubMed Central

    Hancox, Robert J.; Gray, Andrew R.; Sears, Malcolm R.; Poulton, Richie

    2016-01-01

    Background Systemic inflammation is associated with impaired lung function in healthy adults as well as in patients with lung disease. The mechanism for this association is unknown and it is unclear if systemic inflammation leads to impaired lung function or if poor lung function leads to inflammation. We explored the temporal associations between blood C-reactive protein (CRP), fibrinogen, and white blood cells, and lung function in young adults. Methods Spirometry, plethysmography, and diffusion capacity were measured in a population-based cohort at ages 32 and 38 years. High-sensitivity CRP, fibrinogen, and white blood cells were measured at the same ages. Results Higher levels of CRP and, to a lesser extent, fibrinogen were associated with lower lung volumes in cross-sectional analyses at both ages 32 and 38 years. Higher CRP and fibrinogen at age 32 were associated with higher FEV1 and FEV1/FVC at age 38, but not other measures of lung function. Lower lung volumes (total lung capacity, functional residual capacity, and residual volume) but not airflow obstruction (FEV1/FVC) at age 32 were associated with higher CRP at age 38. Associations between age 32 lung function and fibrinogen at follow-up were weaker, but consistent. There were no longitudinal associations between white blood cells and lung function. Conclusions We found no evidence that systemic inflammation causes a decline in lung function. However, lower lung volumes were associated with higher CRP and fibrinogen at follow-up indicating that pulmonary restriction may be a risk factor for systemic inflammation. The mechanism for this association remains unclear. PMID:26733230

  5. Starting a Lung Transplant Program

    PubMed Central

    Eberlein, Michael; Geist, Lois; Keech, John; Zabner, Joseph; Gruber, Peter J.; Iannettoni, Mark D.; Parekh, Kalpaj

    2015-01-01

    Lung transplantation is an effective therapy for many patients with end-stage lung disease. Few centers across the United States offer this therapy, as a successful lung transplant program requires significant institutional resources and specialized personnel. Analysis of the United Network of Organ Sharing database reveals that the failure rate of new programs exceeds 40%. These data suggest that an accurate assessment of program viability as well as a strategy to continuously assess defined quality measures is needed. As part of strategic planning, regional availability of recipient and donors should be assessed. Additionally, analysis of institutional expertise at the physician, support staff, financial, and administrative levels is necessary. In May of 2007, we started a new lung transplant program at the University of Iowa Hospitals and Clinics and have performed 101 transplants with an average recipient 1-year survival of 91%, placing our program among the top in the country for the past 5 years. Herein, we review internal and external factors that impact the viability of a new lung transplant program. We discuss the use of four prospectively identified quality measures: volume, recipient outcomes, financial solvency, and academic contribution as one approach to achieve programmatic excellence. PMID:25940255

  6. Pseudo-absolute quantitative analysis using gas chromatography - Vacuum ultraviolet spectroscopy - A tutorial.

    PubMed

    Bai, Ling; Smuts, Jonathan; Walsh, Phillip; Qiu, Changling; McNair, Harold M; Schug, Kevin A

    2017-02-08

    The vacuum ultraviolet detector (VUV) is a new non-destructive mass sensitive detector for gas chromatography that continuously and rapidly collects full wavelength range absorption between 120 and 240 nm. In addition to conventional methods of quantification (internal and external standard), gas chromatography - vacuum ultraviolet spectroscopy has the potential for pseudo-absolute quantification of analytes based on pre-recorded cross sections (well-defined absorptivity across the 120-240 nm wavelength range recorded by the detector) without the need for traditional calibration. The pseudo-absolute method was used in this research to experimentally evaluate the sources of sample loss and gain associated with sample introduction into a typical gas chromatograph. Standard samples of benzene and natural gas were used to assess precision and accuracy for the analysis of liquid and gaseous samples, respectively, based on the amount of analyte loaded on-column. Results indicate that injection volume, split ratio, and sampling times for splitless analysis can all contribute to inaccurate, yet precise sample introduction. For instance, an autosampler can very reproducibly inject a designated volume, but there are significant systematic errors (here, a consistently larger volume than that designated) in the actual volume introduced. The pseudo-absolute quantification capability of the vacuum ultraviolet detector provides a new means for carrying out system performance checks and potentially for solving challenging quantitative analytical problems. For practical purposes, an internal standardized approach to normalize systematic errors can be used to perform quantitative analysis with the pseudo-absolute method.

  7. Absolute Spectrophotometry of 237 Open Cluster Stars

    NASA Astrophysics Data System (ADS)

    Clampitt, L.; Burstein, D.

    1994-12-01

    We present absolute spectrophotometry of 237 stars in 7 nearby open clusters: Hyades, Pleiades, Alpha Persei, Praesepe, Coma Berenices, IC 4665, and M 39. The observations were taken using the Wampler single-channel scanner (Wampler 1966) on the Crossley 0.9m telescope at Lick Observatory from July 1973 through December 1974. 21 bandpasses spanning the spectral range 3500 Angstroms to 7780 Angstroms were observed for each star, with bandwiths ranging from 32Angstroms to 64 Angstroms. Data are standardized to the Hayes--Latham (1975) system. Our measurements are compared to filter colors on the Johnson BV, Stromgren ubvy, and Geneva U V B_1 B_2 V_1 G systems, as well as to spectrophotometry of a few stars published by Gunn, Stryker & Tinsley and in the Spectrophotometric Standards Catalog (Adelman; as distributed by the NSSDC). Both internal and external comparisons to the filter systems indicate a formal statistical accuracy per bandpass of 0.01 to 0.02 mag, with apparent larger ( ~ 0.03 mag) differences in absolute calibration between this data set and existing spectrophotometry. These data will comprise part of the spectrophotometry that will be used to calibrate the Beijing-Arizona-Taipei-Connecticut Color Survey of the Sky (see separate paper by Burstein et al. at this meeting).

  8. Linear ultrasonic motor for absolute gravimeter.

    PubMed

    Jian, Yue; Yao, Zhiyuan; Silberschmidt, Vadim V

    2017-02-01

    Thanks to their compactness and suitability for vacuum applications, linear ultrasonic motors are considered as substitutes for classical electromagnetic motors as driving elements in absolute gravimeters. Still, their application is prevented by relatively low power output. To overcome this limitation and provide better stability, a V-type linear ultrasonic motor with a new clamping method is proposed for a gravimeter. In this paper, a mechanical model of stators with flexible clamping components is suggested, according to a design criterion for clamps of linear ultrasonic motors. After that, an effect of tangential and normal rigidity of the clamping components on mechanical output is studied. It is followed by discussion of a new clamping method with sufficient tangential rigidity and a capability to facilitate pre-load. Additionally, a prototype of the motor with the proposed clamping method was fabricated and the performance tests in vertical direction were implemented. Experimental results show that the suggested motor has structural stability and high dynamic performance, such as no-load speed of 1.4m/s and maximal thrust of 43N, meeting the requirements for absolute gravimeters.

  9. Why to compare absolute numbers of mitochondria.

    PubMed

    Schmitt, Sabine; Schulz, Sabine; Schropp, Eva-Maria; Eberhagen, Carola; Simmons, Alisha; Beisker, Wolfgang; Aichler, Michaela; Zischka, Hans

    2014-11-01

    Prompted by pronounced structural differences between rat liver and rat hepatocellular carcinoma mitochondria, we suspected these mitochondrial populations to differ massively in their molecular composition. Aiming to reveal these mitochondrial differences, we came across the issue on how to normalize such comparisons and decided to focus on the absolute number of mitochondria. To this end, fluorescently stained mitochondria were quantified by flow cytometry. For rat liver mitochondria, this approach resulted in mitochondrial protein contents comparable to earlier reports using alternative methods. We determined similar protein contents for rat liver, heart and kidney mitochondria. In contrast, however, lower protein contents were determined for rat brain mitochondria and for mitochondria from the rat hepatocellular carcinoma cell line McA 7777. This result challenges mitochondrial comparisons that rely on equal protein amounts as a typical normalization method. Exemplarily, we therefore compared the activity and susceptibility toward inhibition of complex II of rat liver and hepatocellular carcinoma mitochondria and obtained significant discrepancies by either normalizing to protein amount or to absolute mitochondrial number. Importantly, the latter normalization, in contrast to the former, demonstrated a lower complex II activity and higher susceptibility toward inhibition in hepatocellular carcinoma mitochondria compared to liver mitochondria. These findings demonstrate that solely normalizing to protein amount may obscure essential molecular differences between mitochondrial populations.

  10. The absolute threshold of cone vision

    PubMed Central

    Koeing, Darran; Hofer, Heidi

    2013-01-01

    We report measurements of the absolute threshold of cone vision, which has been previously underestimated due to sub-optimal conditions or overly strict subjective response criteria. We avoided these limitations by using optimized stimuli and experimental conditions while having subjects respond within a rating scale framework. Small (1′ fwhm), brief (34 msec), monochromatic (550 nm) stimuli were foveally presented at multiple intensities in dark-adapted retina for 5 subjects. For comparison, 4 subjects underwent similar testing with rod-optimized stimuli. Cone absolute threshold, that is, the minimum light energy for which subjects were just able to detect a visual stimulus with any response criterion, was 203 ± 38 photons at the cornea, ∼0.47 log units lower than previously reported. Two-alternative forced-choice measurements in a subset of subjects yielded consistent results. Cone thresholds were less responsive to criterion changes than rod thresholds, suggesting a limit to the stimulus information recoverable from the cone mosaic in addition to the limit imposed by Poisson noise. Results were consistent with expectations for detection in the face of stimulus uncertainty. We discuss implications of these findings for modeling the first stages of human cone vision and interpreting psychophysical data acquired with adaptive optics at the spatial scale of the receptor mosaic. PMID:21270115

  11. [Estimation of absolute risk for fracture].

    PubMed

    Fujiwara, Saeko

    2009-03-01

    Osteoporosis treatment aims to prevent fractures and maintain the QOL of the elderly. However, persons at high risk of future fracture cannot be effectively identified on the basis of bone density (BMD) alone, although BMD is used as an diagnostic criterion. Therefore, the WHO recommended that absolute risk for fracture (10-year probability of fracture) for each individual be evaluated and used as an index for intervention threshold. The 10-year probability of fracture is calculated based on age, sex, BMD at the femoral neck (body mass index if BMD is not available), history of previous fractures, parental hip fracture history, smoking, steroid use, rheumatoid arthritis, secondary osteoporosis and alcohol consumption. The WHO has just announced the development of a calculation tool (FRAX: WHO Fracture Risk Assessment Tool) in February this year. Fractures could be prevented more effectively if, based on each country's medical circumstances, an absolute risk value for fracture to determine when to start medical treatment is established and persons at high risk of fracture are identified and treated accordingly.

  12. Absolute stereochemistry of altersolanol A and alterporriols.

    PubMed

    Kanamaru, Saki; Honma, Miho; Murakami, Takanori; Tsushima, Taro; Kudo, Shinji; Tanaka, Kazuaki; Nihei, Ken-Ichi; Nehira, Tatsuo; Hashimoto, Masaru

    2012-02-01

    The absolute stereochemistry of altersolanol A (1) was established by observing a positive exciton couplet in the circular dichroism (CD) spectrum of the C3,C4-O-bis(2-naphthoyl) derivative 10 and by chemical correlations with known compound 8. Before the discussion, the relative stereochemistry of 1 was confirmed by X-ray crystallographic analysis. The shielding effect at C7'-OMe group by C1-O-benzoylation established the relative stereochemical relationship between the C8-C8' axial bonding and the C1-C4/C1'-C4' polyol moieties of alterporriols E (3), an atropisomer of the C8-C8' dimer of 1. As 3 could be obtained by dimerization of 1 in vitro, the absolute configuration of its central chirality elements (C1-C4) must be identical to those of 1. Spectral comparison between the experimental and theoretical CD spectra supported the above conclusion. Axial stereochemistry of novel C4-O-deoxy dimeric derivatives, alterporriols F (4) and G (5), were also revealed by comparison of their CD spectra to those of 2 and 3.

  13. Absolute Electron Extraction Efficiency of Liquid Xenon

    NASA Astrophysics Data System (ADS)

    Kamdin, Katayun; Mizrachi, Eli; Morad, James; Sorensen, Peter

    2016-03-01

    Dual phase liquid/gas xenon time projection chambers (TPCs) currently set the world's most sensitive limits on weakly interacting massive particles (WIMPs), a favored dark matter candidate. These detectors rely on extracting electrons from liquid xenon into gaseous xenon, where they produce proportional scintillation. The proportional scintillation from the extracted electrons serves to internally amplify the WIMP signal; even a single extracted electron is detectable. Credible dark matter searches can proceed with electron extraction efficiency (EEE) lower than 100%. However, electrons systematically left at the liquid/gas boundary are a concern. Possible effects include spontaneous single or multi-electron proportional scintillation signals in the gas, or charging of the liquid/gas interface or detector materials. Understanding EEE is consequently a serious concern for this class of rare event search detectors. Previous EEE measurements have mostly been relative, not absolute, assuming efficiency plateaus at 100%. I will present an absolute EEE measurement with a small liquid/gas xenon TPC test bed located at Lawrence Berkeley National Laboratory.

  14. Standardization of the cumulative absolute velocity

    SciTech Connect

    O'Hara, T.F.; Jacobson, J.P. )

    1991-12-01

    EPRI NP-5930, A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set.

  15. Swarm's Absolute Scalar Magnetometers Burst Mode Results

    NASA Astrophysics Data System (ADS)

    Coisson, P.; Vigneron, P.; Hulot, G.; Crespo Grau, R.; Brocco, L.; Lalanne, X.; Sirol, O.; Leger, J. M.; Jager, T.; Bertrand, F.; Boness, A.; Fratter, I.

    2014-12-01

    Each of the three Swarm satellites embarks an Absolute Scalar Magnetometer (ASM) to provide absolute scalar measurements of the magnetic field with high accuracy and stability. Nominal data acquisition of these ASMs is 1 Hz. But they can also run in a so-called "burst mode" and provide data at 250 Hz. During the commissioning phase of the mission, seven burst mode acquisition campaigns have been run simultaneously for all satellites, obtaining a total of ten days of burs-mode data. These campaigns allowed the identification of issues related to the operations of the piezo-electric motor and the heaters connected to the ASM, that do not impact the nominal 1 Hz scalar data. We analyze the burst mode data to identify high frequency geomagnetic signals, focusing the analysis in two regions: the low latitudes, where we seek signatures of ionospheric irregularities, and the high latitudes, to identify high frequency signals related to polar region currents. Since these campaigns have been conducted during the initial months of the mission, the three satellites where still close to each other, allowing to analyze the spatial coherency of the signals. Wavelet analysis have revealed 31 Hz signals appearing in the night-side in the equatorial region.

  16. Extracting infrared absolute reflectance from relative reflectance measurements.

    PubMed

    Berets, Susan L; Milosevic, Milan

    2012-06-01

    Absolute reflectance measurements are valuable to the optics industry for development of new materials and optical coatings. Yet, absolute reflectance measurements are notoriously difficult to make. In this paper, we investigate the feasibility of extracting the absolute reflectance from a relative reflectance measurement using a reference material with known refractive index.

  17. A Conceptual Approach to Absolute Value Equations and Inequalities

    ERIC Educational Resources Information Center

    Ellis, Mark W.; Bryson, Janet L.

    2011-01-01

    The absolute value learning objective in high school mathematics requires students to solve far more complex absolute value equations and inequalities. When absolute value problems become more complex, students often do not have sufficient conceptual understanding to make any sense of what is happening mathematically. The authors suggest that the…

  18. Simple, Inexpensive Model Spirometer for Understanding Ventilation Volumes

    ERIC Educational Resources Information Center

    Giuliodori, Mauricio J.; DiCarlo, Stephen E.

    2004-01-01

    Spirometers are useful for enhancing students' understanding of normal lung volumes, capacities, and flow rates. Spirometers are also excellent for understanding how lung diseases alter ventilation volumes. However, spirometers are expensive, complex, and not appropriate for programs with limited space and budgets. Therefore, we developed a…

  19. Lung diffusion testing

    MedlinePlus

    ... as: Emphysema Interstitial fibrosis Pulmonary embolism Pulmonary hypertension Sarcoidosis Lung hemorrhage Asthma Risks There are no significant ... Read More Asbestosis Interstitial lung disease Lung disease Sarcoidosis Review Date 11/19/2015 Updated by: Denis ...

  20. Lung Carcinoid Tumor: Surgery

    MedlinePlus

    ... Tumor Treating Lung Carcinoid Tumors Surgery to Treat Lung Carcinoid Tumors Surgery is the main treatment for ... often be cured by surgery alone. Types of lung surgery Different operations can be used to treat ( ...

  1. Study of the absolute bioavailability of citrocard, a new GABA derivative.

    PubMed

    Smirnova, L A; Perfilova, V N; Tyurenkov, I N; Ryabukha, A F; Suchkov, E A; Lebedeva, S A

    2013-08-01

    The main pharmacokinetic parameters attest to short elimination half-life and mean retention time of a single citrocard molecule. The average rate of plasma concentration decrease of the compound determined small area under the pharmacokinetic curve. Steady-state distribution volume was low and only slightly surpassed the volume of extracellular body fluids in rat, which indicated moderate capacity of citrocard to distribution and accumulation in the tissues, which is seen from low systemic clearance (Cl) despite the quick elimination of the compound. Absolute bioavailability was 64%.

  2. Split-step eigenvector-following technique for exploring enthalpy landscapes at absolute zero.

    PubMed

    Mauro, John C; Loucks, Roger J; Balakrishnan, Jitendra

    2006-03-16

    The mapping of enthalpy landscapes is complicated by the coupling of particle position and volume coordinates. To address this issue, we have developed a new split-step eigenvector-following technique for locating minima and transition points in an enthalpy landscape at absolute zero. Each iteration is split into two steps in order to independently vary system volume and relative atomic coordinates. A separate Lagrange multiplier is used for each eigendirection in order to provide maximum flexibility in determining step sizes. This technique will be useful for mapping the enthalpy landscapes of bulk systems such as supercooled liquids and glasses.

  3. Quantifying lung shunting during planning for radio-embolization

    NASA Astrophysics Data System (ADS)

    Willowson, Kathy; Bailey, Dale L.; Baldock, Clive

    2011-07-01

    A method is proposed for accurate quantification of lung uptake during shunt studies for liver cancer patients undergoing radio-embolization. The current standard for analysis of [99mTc]-MAA shunt studies is subjective and highly variable. The technique proposed in this work involves a small additional peripheral intravenous injection of macroaggregated albumin (MAA) and two additional static acquisitions (before and after injection) to quantify the absolute activity in the lungs as a result of arterio-venous shunting. Such quantification also allows for estimates of absorbed dose to lung tissue at the time of treatment based on MIRD formalism. The method was used on six radio-embolization patients attending the department for lung shunt analysis. Quantitative values for each were compared to a previously validated technique using fully quantitative SPECT/CT imaging, treated as the gold standard. The average difference between absolute activity shunted to the lungs calculated by the proposed technique compared to the previously validated technique was found to be 2%, with a range of (1-8)%. The proposed method is simple and fast, allowing for accurate quantification of lung shunting and estimates of absorbed dose to lung tissue at treatment, and may one day be used in a one-stop procedure for planning and therapy in a single interventional procedure.

  4. Humidification of base flow gas during adult high-frequency oscillatory ventilation: an experimental study using a lung model.

    PubMed

    Shiba, Naoki; Nagano, Osamu; Hirayama, Takahiro; Ichiba, Shingo; Ujike, Yoshihito

    2012-01-01

    In adult high-frequency oscillatory ventilation (HFOV) with an R100 artificial ventilator, exhaled gas from patient's lung may warm the temperature probe and thereby disturb the humidification of base flow (BF) gas. We measured the humidity of BF gas during HFOV with frequencies of 6, 8 and 10 Hz, maximum stroke volumes (SV) of 285, 205, and 160 ml at the respective frequencies, and, BFs of 20, 30, 40 l/min using an original lung model. The R100 device was equipped with a heated humidifier, Hummax Ⅱ, consisting of a porous hollow fiber in circuit. A 50-cm length of circuit was added between temperature probe (located at 50 cm proximal from Y-piece) and the hollow fiber. The lung model was made of a plastic container and a circuit equipped with another Hummax Ⅱ. The lung model temperature was controlled at 37℃. The Hummax Ⅱ of the R100 was inactivated in study-1 and was set at 35℃ or 37℃ in study-2. The humidity was measured at the distal end of the added circuit in study-1 and at the proximal end in study-2. In study-1, humidity was detected at 6 Hz (SV 285 ml) and BF 20 l/min, indicating the direct reach of the exhaled gas from the lung model to the temperature probe. In study-2 the absolute humidity of the BF gas decreased by increasing SV and by increasing BF and it was low with setting of 35℃. In this study setting, increasing the SV induced significant reduction of humidification of the BF gas during HFOV with R100.

  5. Use of Absolute and Comparative Performance Feedback in Absolute and Comparative Judgments and Decisions

    ERIC Educational Resources Information Center

    Moore, Don A.; Klein, William M. P.

    2008-01-01

    Which matters more--beliefs about absolute ability or ability relative to others? This study set out to compare the effects of such beliefs on satisfaction with performance, self-evaluations, and bets on future performance. In Experiment 1, undergraduate participants were told they had answered 20% correct, 80% correct, or were not given their…

  6. Lung surgery - discharge

    MedlinePlus

    Thoracotomy - discharge; Lung tissue removal - discharge; Pneumonectomy - discharge; Lobectomy - discharge; Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - ...

  7. Ultrasound-induced lung hemorrhage: Role of acoustic boundary conditions at the pleural surface

    NASA Astrophysics Data System (ADS)

    O'Brien, William D.; Kramer, Jeffrey M.; Waldrop, Tony G.; Frizzell, Leon A.; Miller, Rita J.; Blue, James P.; Zachary, James F.

    2002-02-01

    In a previous study [J. Acoust. Soc. Am. 108, 1290 (2000)] the acoustic impedance difference between intercostal tissue and lung was evaluated as a possible explanation for the enhanced lung damage with increased hydrostatic pressure, but the hydrostatic-pressure-dependent impedance difference alone could not explain the enhanced occurrence of hemorrhage. In that study, it was hypothesized that the animal's breathing pattern might be altered as a function of hydrostatic pressure, which in turn might affect the volume of air inspired and expired. The acoustic impedance difference between intercostal tissue and lung would be affected with altered lung inflation, thus altering the acoustic boundary conditions. In this study, 12 rats were exposed to 3 volumes of lung inflation (inflated: approximately tidal volume; half-deflated: half-tidal volume; deflated: lung volume at functional residual capacity), 6 rats at 8.6-MPa in situ peak rarefactional pressure (MI of 3.1) and 6 rats at 16-MPa in situ peak rarefactional pressure (MI of 5.8). Respiration was chemically inhibited and a ventilator was used to control lung volume and respiratory frequency. Superthreshold ultrasound exposures of the lungs were used (3.1-MHz, 1000-Hz PRF, 1.3-μs pulse duration, 10-s exposure duration) to produce lesions. Deflated lungs were more easily damaged than half-deflated lungs, and half-deflated lungs were more easily damaged than inflated lungs. In fact, there were no lesions observed in inflated lungs in any of the rats. The acoustic impedance difference between intercostal tissue and lung is much less for the deflated lung condition, suggesting that the extent of lung damage is related to the amount of acoustic energy that is propagated across the pleural surface boundary.

  8. Regional distribution of lung compliance by image analysis of computed tomograms.

    PubMed

    Perchiazzi, Gaetano; Rylander, Christian; Derosa, Savino; Pellegrini, Mariangela; Pitagora, Loredana; Polieri, Debora; Vena, Antonio; Tannoia, Angela; Fiore, Tommaso; Hedenstierna, Göran

    2014-09-15

    Computed tomography (CT) can yield quantitative information about volume distribution in the lung. By combining information provided by CT and respiratory mechanics, this study aims at quantifying regional lung compliance (CL) and its distribution and homogeneity in mechanically ventilated pigs. The animals underwent inspiratory hold maneuvers at 12 lung volumes with simultaneous CT exposure at two end-expiratory pressure levels and before and after acute lung injury (ALI) by oleic acid administration. CL and the sum of positive voxel compliances from CT were linearly correlated; negative compliance areas were found. A remarkably heterogeneous distribution of voxel compliance was found in the injured lungs. As the lung inflation increased, the homogeneity increased in healthy lungs but decreased in injured lungs. Image analysis brought novel findings regarding spatial homogeneity of compliance, which increases in ALI but not in healthy lungs by applying PEEP after a recruitment maneuver.

  9. Absolute nonlocality via distributed computing without communication

    NASA Astrophysics Data System (ADS)

    Czekaj, Ł.; Pawłowski, M.; Vértesi, T.; Grudka, A.; Horodecki, M.; Horodecki, R.

    2015-09-01

    Understanding the role that quantum entanglement plays as a resource in various information processing tasks is one of the crucial goals of quantum information theory. Here we propose an alternative perspective for studying quantum entanglement: distributed computation of functions without communication between nodes. To formalize this approach, we propose identity games. Surprisingly, despite no signaling, we obtain that nonlocal quantum strategies beat classical ones in terms of winning probability for identity games originating from certain bipartite and multipartite functions. Moreover we show that, for a majority of functions, access to general nonsignaling resources boosts success probability two times in comparison to classical ones for a number of large enough outputs. Because there are no constraints on the inputs and no processing of the outputs in the identity games, they detect very strong types of correlations: absolute nonlocality.

  10. In vivo absorption spectroscopy for absolute measurement.

    PubMed

    Furukawa, Hiromitsu; Fukuda, Takashi

    2012-10-01

    In in vivo spectroscopy, there are differences between individual subjects in parameters such as tissue scattering and sample concentration. We propose a method that can provide the absolute value of a particular substance concentration, independent of these individual differences. Thus, it is not necessary to use the typical statistical calibration curve, which assumes an average level of scattering and an averaged concentration over individual subjects. This method is expected to greatly reduce the difficulties encountered during in vivo measurements. As an example, for in vivo absorption spectroscopy, the method was applied to the reflectance measurement in retinal vessels to monitor their oxygen saturation levels. This method was then validated by applying it to the tissue phantom under a variety of absorbance values and scattering efficiencies.

  11. Determining Absolute Zero Using a Tuning Fork

    NASA Astrophysics Data System (ADS)

    Goldader, Jeffrey D.

    2008-04-01

    The Celsius and Kelvin temperature scales, we tell our students, are related. We explain that a change in temperature of 1°C corresponds to a change of 1 Kelvin and that atoms and molecules have zero kinetic energy at zero Kelvin, -273°C. In this paper, we will show how students can derive the relationship between the Celsius and Kelvin temperature scales using a simple, well-known physics experiment. By making multiple measurements of the speed of sound at different temperatures, using the classic physics experiment of determining the speed of sound with a tuning fork and variable-length tube, they can determine the temperature at which the speed of sound is zero—absolute zero.

  12. MAGSAT: Vector magnetometer absolute sensor alignment determination

    NASA Technical Reports Server (NTRS)

    Acuna, M. H.

    1981-01-01

    A procedure is described for accurately determining the absolute alignment of the magnetic axes of a triaxial magnetometer sensor with respect to an external, fixed, reference coordinate system. The method does not require that the magnetic field vector orientation, as generated by a triaxial calibration coil system, be known to better than a few degrees from its true position, and minimizes the number of positions through which a sensor assembly must be rotated to obtain a solution. Computer simulations show that accuracies of better than 0.4 seconds of arc can be achieved under typical test conditions associated with existing magnetic test facilities. The basic approach is similar in nature to that presented by McPherron and Snare (1978) except that only three sensor positions are required and the system of equations to be solved is considerably simplified. Applications of the method to the case of the MAGSAT Vector Magnetometer are presented and the problems encountered discussed.

  13. An estimate of global absolute dynamic topography

    NASA Technical Reports Server (NTRS)

    Tai, C.-K.; Wunsch, C.

    1984-01-01

    The absolute dynamic topography of the world ocean is estimated from the largest scales to a short-wavelength cutoff of about 6700 km for the period July through September, 1978. The data base consisted of the time-averaged sea-surface topography determined by Seasat and geoid estimates made at the Goddard Space Flight Center. The issues are those of accuracy and resolution. Use of the altimetric surface as a geoid estimate beyond the short-wavelength cutoff reduces the spectral leakage in the estimated dynamic topography from erroneous small-scale geoid estimates without contaminating the low wavenumbers. Comparison of the result with a similarly filtered version of Levitus' (1982) historical average dynamic topography shows good qualitative agreement. There is quantitative disagreement, but it is within the estimated errors of both methods of calculation.

  14. Micron Accurate Absolute Ranging System: Range Extension

    NASA Technical Reports Server (NTRS)

    Smalley, Larry L.; Smith, Kely L.

    1999-01-01

    The purpose of this research is to investigate Fresnel diffraction as a means of obtaining absolute distance measurements with micron or greater accuracy. It is believed that such a system would prove useful to the Next Generation Space Telescope (NGST) as a non-intrusive, non-contact measuring system for use with secondary concentrator station-keeping systems. The present research attempts to validate past experiments and develop ways to apply the phenomena of Fresnel diffraction to micron accurate measurement. This report discusses past research on the phenomena, and the basis of the use Fresnel diffraction distance metrology. The apparatus used in the recent investigations, experimental procedures used, preliminary results are discussed in detail. Continued research and equipment requirements on the extension of the effective range of the Fresnel diffraction systems is also described.

  15. Absolute measurements of fast neutrons using yttrium.

    PubMed

    Roshan, M V; Springham, S V; Rawat, R S; Lee, P; Krishnan, M

    2010-08-01

    Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f(n) approximately 4.1x10(-4) with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10(8) neutrons per discharge.

  16. Absolute bioavailability of quinine formulations in Nigeria.

    PubMed

    Babalola, C P; Bolaji, O O; Ogunbona, F A; Ezeomah, E

    2004-09-01

    This study compared the absolute bioavailability of quinine sulphate as capsule and as tablet against the intravenous (i.v.) infusion of the drug in twelve male volunteers. Six of the volunteers received intravenous infusion over 4 h as well as the capsule formulation of the drug in a cross-over manner, while the other six received the tablet formulation. Blood samples were taken at predetermined time intervals and plasma analysed for quinine (QN) using reversed-phase HPLC method. QN was rapidly absorbed after the two oral formulations with average t(max) of 2.67 h for both capsule and tablet. The mean elimination half-life of QN from the i.v. and oral dosage forms varied between 10 and 13.5 hr and were not statistically different (P > 0.05). On the contrary, the maximum plasma concentration (C(max)) and area under the curve (AUC) from capsule were comparable to those from i.v. (P > 0.05), while these values were markedly higher than values from tablet formulation (P < 0.05). The therapeutic QN plasma levels were not achieved with the tablet formulation. The absolute bioavailability (F) were 73% (C.l., 53.3 - 92.4%) and 39 % (C.I., 21.7 - 56.6%) for the capsule and tablet respectively and the difference was significant (P < 0.05). The subtherapeutic levels obtained from the tablet form used in this study may cause treatment failure during malaria and caution should be taken when predictions are made from results obtained from different formulations of QN.

  17. Absolute GPS Positioning Using Genetic Algorithms

    NASA Astrophysics Data System (ADS)

    Ramillien, G.

    A new inverse approach for restoring the absolute coordinates of a ground -based station from three or four observed GPS pseudo-ranges is proposed. This stochastic method is based on simulations of natural evolution named genetic algorithms (GA). These iterative procedures provide fairly good and robust estimates of the absolute positions in the Earth's geocentric reference system. For comparison/validation, GA results are compared to the ones obtained using the classical linearized least-square scheme for the determination of the XYZ location proposed by Bancroft (1985) which is strongly limited by the number of available observations (i.e. here, the number of input pseudo-ranges must be four). The r.m.s. accuracy of the non -linear cost function reached by this latter method is typically ~10-4 m2 corresponding to ~300-500-m accuracies for each geocentric coordinate. However, GA can provide more acceptable solutions (r.m.s. errors < 10-5 m2), even when only three instantaneous pseudo-ranges are used, such as a lost of lock during a GPS survey. Tuned GA parameters used in different simulations are N=1000 starting individuals, as well as Pc=60-70% and Pm=30-40% for the crossover probability and mutation rate, respectively. Statistical tests on the ability of GA to recover acceptable coordinates in presence of important levels of noise are made simulating nearly 3000 random samples of erroneous pseudo-ranges. Here, two main sources of measurement errors are considered in the inversion: (1) typical satellite-clock errors and/or 300-metre variance atmospheric delays, and (2) Geometrical Dilution of Precision (GDOP) due to the particular GPS satellite configuration at the time of acquisition. Extracting valuable information and even from low-quality starting range observations, GA offer an interesting alternative for high -precision GPS positioning.

  18. Radiation Therapy for Lung Cancer

    MedlinePlus

    ... are available to help. HELPFUL WEB SITES ON LUNG CANCER American Lung Association www.lung.org Lungcancer.org www.lungcancer.org Lung Cancer Alliance www.lungcanceralliance.org Lung Cancer Online www. ...

  19. Analysis of Lung Flute-collected Sputum for Lung Cancer Diagnosis.

    PubMed

    Su, Jian; Anjuman, Nigar; Guarnera, Maria A; Zhang, Howard; Stass, Sanford A; Jiang, Feng

    2015-01-01

    Molecular analysis of sputum can help diagnose lung cancer. We have demonstrated that Lung Flute can be used to collect sputum from individuals who cannot spontaneously expectorate sputum. The objective of this study is to further evaluate the performance of the Lung Flute by comparing the characteristics of parallel samples collected with and without the Lung Flute and the usefulness for diagnosis of lung cancer. Fifty-six early-stage lung cancer patients (40 current smokers and 16 former smokers) and 73 cancer-free individuals (52 current smokers and 21 former smokers) were instructed to spontaneously cough and use Lung Flute for sputum sampling. Sputum cytology and polymerase chain reaction analysis of three miRNAs (miRs-21, 31, and 210) were performed in the specimens. All 92 current smokers and 11 (28.7%) of 37 former smokers spontaneously expectorated sputum and also produced sputum when using the Lung Flute. Twenty-seven former smokers (70.3%) who could not spontaneously expectorate sputum, however, were able to produce sputum when using the Lung Flute. The specimens were of low respiratory origin without contamination from other sources, eg, saliva. There was no difference of sputum volume and cell populations, diagnostic efficiency of cytology, and analysis of the miRNAs in the specimens collected by the two approaches. Analysis of the sputum miRNAs produced 83.93% sensitivity and 87.67% specificity for identifying lung cancer. Therefore, sputum collected by the Lung Flute has comparable features as spontaneously expectorated sputum. Using the Lung Flute enables former smokers who cannot spontaneously expectorate to provide adequate sputum to improve sputum collection for lung cancer diagnosis.

  20. Connecting the Dots: From Absolutes to Continua

    ERIC Educational Resources Information Center

    Marshall, Herbert D.

    2005-01-01

    The article focuses on learning music among children. It is said that in general music, many concepts are introduced to young students. Most teachers have learned the mental health survival skill of teaching the appropriate use of an outdoor voice, an indoor voice, and a whisper voice. Tempo is much the same argument as volume. (Contains 2…

  1. Phantom Validation of Tc-99m Absolute Quantification in a SPECT/CT Commercial Device

    PubMed Central

    Leite Ferreira, Paulo; Malterre, Jerome; Laub, Priscille; Prior, John O.; Verdun, Francis R.

    2016-01-01

    Aim. Similar to PET, absolute quantitative imaging is becoming available in commercial SPECT/CT devices. This study's goal was to assess quantitative accuracy of activity recovery as a function of image reconstruction parameters and count statistics in a variety of phantoms. Materials and Methods. We performed quantitative 99mTc-SPECT/CT acquisitions (Siemens Symbia Intevo, Erlangen, Germany) of a uniform cylindrical, NEMA/IEC, and an anthropomorphic abdominal phantom. Background activity concentrations tested ranged: 2–80 kBq/mL. SPECT acquisitions used 120 projections (20 s/projection). Reconstructions were performed with the proprietary iterative conjugate gradient algorithm. NEMA phantom reconstructions were obtained as a function of the iteration number (range: 4–48). Recovery coefficients, hot contrast, relative lung error (NEMA phantom), and image noise were assessed. Results. In all cases, absolute activity and activity concentration were measured within 10% of the expected value. Recovery coefficients and hot contrast in hot inserts did not vary appreciably with count statistics. RC converged at 16 iterations for insert size > 22 mm. Relative lung errors were comparable to PET levels indicating the efficient integration of attenuation and scatter corrections with adequate detector modeling. Conclusions. The tested device provided accurate activity recovery within 10% of correct values; these performances are comparable to current generation PET/CT systems. PMID:28096891

  2. Absolute electrical impedance tomography (aEIT) guided ventilation therapy in critical care patients: simulations and future trends.

    PubMed

    Denaï, Mouloud A; Mahfouf, Mahdi; Mohamad-Samuri, Suzani; Panoutsos, George; Brown, Brian H; Mills, Gary H

    2010-05-01

    Thoracic electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring technique whose aim is to reconstruct a cross-sectional image of the internal spatial distribution of conductivity from electrical measurements made by injecting small alternating currents via an electrode array placed on the surface of the thorax. The purpose of this paper is to discuss the fundamentals of EIT and demonstrate the principles of mechanical ventilation, lung recruitment, and EIT imaging on a comprehensive physiological model, which combines a model of respiratory mechanics, a model of the human lung absolute resistivity as a function of air content, and a 2-D finite-element mesh of the thorax to simulate EIT image reconstruction during mechanical ventilation. The overall model gives a good understanding of respiratory physiology and EIT monitoring techniques in mechanically ventilated patients. The model proposed here was able to reproduce consistent images of ventilation distribution in simulated acutely injured and collapsed lung conditions. A new advisory system architecture integrating a previously developed data-driven physiological model for continuous and noninvasive predictions of blood gas parameters with the regional lung function data/information generated from absolute EIT (aEIT) is proposed for monitoring and ventilator therapy management of critical care patients.

  3. Noninvasive absolute cerebral oximetry with frequency-domain near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Hallacoglu, Bertan

    Near-infrared spectroscopy (NIRS) measurements of absolute concentrations of oxy-hemoglobin and deoxy-hemoglobin in the human brain can provide critical information about cerebral physiology in terms of cerebral blood volume, blood flow, oxygen delivery, and metabolic rate of oxygen. We developed several frequency domain NIRS data acquisition and analysis methods aimed at absolute measurements of hemoglobin concentration and saturation in cerebral tissue of adult human subjects. Extensive experimental investigations were carried out in various homogenous and two-layered tissue-mimicking phantoms, and biological tissues. The advantages and limitations of commonly used homogenous models and inversion strategies were thoroughly investigated. Prior to human subjects, extensive studies were carried out in in vivo animal models. In rabbits, absolute hemoglobin oxygen desaturation was shown to depend strongly on surgically induced testicular torsion. Methods developed in this study were then adapted for measurements in the rat brain. Absolute values were demonstrated to discern cerebrovascular impairment in a rat model of diet-induced vascular cognitive impairment. These results facilitated the development of clinically useful optical measures of cerebrovascular health. In a large group of human subjects, employing a homogeneous model for absolute measurements was shown to be reliable and robust. However, it was also shown to be limited due to the relatively thick extracerebral tissue. The procedure we develop in this work and the thesis thereof performs a nonlinear inversion procedure with six unknown parameters with no other prior knowledge for the retrieval of the optical coefficients and top layer thickness with high accuracy on two-layered media. Our absolute measurements of cerebral hemoglobin concentration and saturation are based on the discrimination of extracerebral and cerebral tissue layers, and they can enhance the impact of NIRS for cerebral hemodynamics and

  4. Mechanical properties of the lungs during acclimatization to altitude.

    PubMed

    Gautier, H; Peslin, R; Grassino, A; Milic-Emili, J; Hannhart, B; Powell, E; Miserocchi, G; Bonora, M; Fischer, J T

    1982-06-01

    Mechanical properties of the lung were studied in nine healthy lowlanders during a 6-day sojourn at an altitude of 3,457 m. In comparison to sea-level values, it was found at altitude that 1) lung volumes measured by plethysmography including total lung capacity, vital capacity, and functional residual capacity (FRC) presented small changes not exceeding 300 ml; 2) static and dynamic lung compliances were not modified but static pressure-volume curves of lungs were shifted progressively to the left (the decrease in lung elastic recoil averaged about 2 cmH2O on days 4-6); and 3) maximal midexpiratory flow, forced expiratory volume in 1 s, and maximal expiratory and inspiratory flows were increased and, conversely, airways and pulmonary flow resistances were decreased on most days at altitude. The unchanged FRC in the face of a decreased lung recoil may be explained by an increase in thoracic blood volume at altitude, but other possible mechanisms are discussed. The decrease in resistances and increase in maximal flows may be partly explained by the decreased air density at altitude, but another contributing factor such as a bronchodilatation is also suggested. It is proposed that changes in lung mechanics at altitude may account for some of the changes in the pattern of breathing and mouth occlusion pressure (P0.1) observed during acclimatization of lowlanders to altitude.

  5. Regional diffusing capacity in normal lungs during a slow exhalation.

    PubMed

    MacIntyre, N R; Nadel, J A

    1982-06-01

    From an analysis of carbon monoxide uptake and xenon-133 distribution after two bolus inhalations of these gases, we calculated regional diffusing capacity in the upper and lower volume halves of the lungs during the middle 60% of an exhaled vital capacity in five seated normal subjects. We found that the regional diffusing capacity of the upper half of the lungs was 11.6 +/- 4.2 (mean +/- SD) ml.min-1.Torr-1 and that the regional diffusing capacity of the lower half of the lungs was 24.4 +/- 2.4 ml.min-1.Torr-1 after 25% of the vital capacity had been exhaled. These values remained relatively constant as lung volume decreased from 25 to 75% of the exhaled vital capacity. Diffusing capacity in the upper half of the lungs ranged from 9.4 to 12.4 ml.min-1.Torr-1 during exhalation, and in the lower half of the lungs from 21.0 to 28.6 ml.min-1.Torr-1 during exhalation. These results suggest that total lung diffusing capacity remains relatively constant over this midrange of lung volumes and that this occurs because the regional diffusing capacities in both the upper and lower halves of the lungs remain relatively constant.

  6. Lung surfactant.

    PubMed Central

    Rooney, S A

    1984-01-01

    Aspects of pulmonary surfactant are reviewed from a biochemical perspective. The major emphasis is on the lipid components of surfactant. Topics reviewed include surfactant composition, cellular and subcellular sites as well as pathways of biosynthesis of phosphatidylcholine, disaturated phosphatidylcholine and phosphatidylglycerol. The surfactant system in the developing fetus and neonate is considered in terms of phospholipid content and composition, rates of precursor incorporation, activities of individual enzymes of phospholipid synthesis and glycogen content and metabolism. The influence of the following hormones and other factors on lung maturation and surfactant production is discussed: glucocorticoids, thyroid hormone, estrogen, prolactin, cyclic AMP, beta-adrenergic and cholinergic agonists, prostaglandins and growth factors. The influence of maternal diabetes, fetal sex, stress and labor are also considered. Nonphysiologic and toxic agents which influence surfactant in the fetus, newborn and adult are reviewed. PMID:6145585

  7. Interstitial Lung Diseases

    MedlinePlus

    Interstitial lung disease is the name for a large group of diseases that inflame or scar the lungs. The inflammation and scarring make it hard to ... air is responsible for some types of interstitial lung diseases. Specific types include Black lung disease among ...

  8. Divers' lung function: small airways disease?

    PubMed Central

    Thorsen, E; Segadal, K; Kambestad, B; Gulsvik, A

    1990-01-01

    Pulmonary function was measured in 152 professional saturation divers and in a matched control group of 106 subjects. Static lung volumes, dynamic lung volumes and flows, transfer factor for carbon monoxide (T1CO), transfer volume per unit alveolar volume (KCO), delta-N2, and closing volume (CV) were measured and compared with reference values from recent Scandinavian studies, British submariners, and the European Community for Coal and Steel (ECCS) recommended reference values. Diving exposure was assessed as years of diving experience, total number of days in saturation and depth, and as the product of days in saturation and mean depth. Divers had significantly lower values for forced expired volume in one second (FEV1), FEV1/forced vital capacity (FVC) ratio, FEF25-75%, FEF75-85%, FEF50%, FEF75%, T1CO, and KCO compared with the controls and a significantly higher CV. There was a positive correlation between diving exposure and CV, whereas the other variables had negative correlations with diving exposure. Values for the control group were not different from the predictive values of Scandinavian reference studies or British submariners, although the ECCS standard predicted significantly lower values for the lung function variables both in divers and the control group. The pattern of the differences in lung function variables between the divers and controls is consistent with small airways dysfunction and with the transient changes in lung function found immediately after a single saturation dive. The association between reduced pulmonary function and previous diving exposure further indicates the presence of cumulative long term effects of diving on pulmonary function. PMID:2393630

  9. Ex vivo lung perfusion.

    PubMed

    Reeb, Jeremie; Cypel, Marcelo

    2016-03-01

    Lung transplantation is an established life-saving therapy for patients with end-stage lung disease. Unfortunately, greater success in lung transplantation is hindered by a shortage of lung donors and the relatively poor early-, mid-, and long-term outcomes associated with severe primary graft dysfunction. Ex vivo lung perfusion has emerged as a modern preservation technique that allows for a more accurate lung assessment and improvement in lung quality. This review outlines the: (i) rationale behind the method; (ii) techniques and protocols; (iii) Toronto ex vivo lung perfusion method; (iv) devices available; and (v) clinical experience worldwide. We also highlight the potential of ex vivo lung perfusion in leading a new era of lung preservation.

  10. Absolute calibration of forces in optical tweezers

    NASA Astrophysics Data System (ADS)

    Dutra, R. S.; Viana, N. B.; Maia Neto, P. A.; Nussenzveig, H. M.

    2014-07-01

    Optical tweezers are highly versatile laser traps for neutral microparticles, with fundamental applications in physics and in single molecule cell biology. Force measurements are performed by converting the stiffness response to displacement of trapped transparent microspheres, employed as force transducers. Usually, calibration is indirect, by comparison with fluid drag forces. This can lead to discrepancies by sizable factors. Progress achieved in a program aiming at absolute calibration, conducted over the past 15 years, is briefly reviewed. Here we overcome its last major obstacle, a theoretical overestimation of the peak stiffness, within the most employed range for applications, and we perform experimental validation. The discrepancy is traced to the effect of primary aberrations of the optical system, which are now included in the theory. All required experimental parameters are readily accessible. Astigmatism, the dominant effect, is measured by analyzing reflected images of the focused laser spot, adapting frequently employed video microscopy techniques. Combined with interface spherical aberration, it reveals a previously unknown window of instability for trapping. Comparison with experimental data leads to an overall agreement within error bars, with no fitting, for a broad range of microsphere radii, from the Rayleigh regime to the ray optics one, for different polarizations and trapping heights, including all commonly employed parameter domains. Besides signaling full first-principles theoretical understanding of optical tweezers operation, the results may lead to improved instrument design and control over experiments, as well as to an extended domain of applicability, allowing reliable force measurements, in principle, from femtonewtons to nanonewtons.

  11. Elevation correction factor for absolute pressure measurements

    NASA Technical Reports Server (NTRS)

    Panek, Joseph W.; Sorrells, Mark R.

    1996-01-01

    With the arrival of highly accurate multi-port pressure measurement systems, conditions that previously did not affect overall system accuracy must now be scrutinized closely. Errors caused by elevation differences between pressure sensing elements and model pressure taps can be quantified and corrected. With multi-port pressure measurement systems, the sensing elements are connected to pressure taps that may be many feet away. The measurement system may be at a different elevation than the pressure taps due to laboratory space or test article constraints. This difference produces a pressure gradient that is inversely proportional to height within the interface tube. The pressure at the bottom of the tube will be higher than the pressure at the top due to the weight of the tube's column of air. Tubes with higher pressures will exhibit larger absolute errors due to the higher air density. The above effect is well documented but has generally been taken into account with large elevations only. With error analysis techniques, the loss in accuracy from elevation can be easily quantified. Correction factors can be applied to maintain the high accuracies of new pressure measurement systems.

  12. What is Needed for Absolute Paleointensity?

    NASA Astrophysics Data System (ADS)

    Valet, J. P.

    2015-12-01

    Many alternative approaches to the Thellier and Thellier technique for absolute paleointensity have been proposed during the past twenty years. One reason is the time consuming aspect of the experiments. Another reason is to avoid uncertainties in determinations of the paleofield which are mostly linked to the presence of multidomain grains. Despite great care taken by these new techniques, there is no indication that they always provide the right answer and in fact sometimes fail. We are convinced that the most valid approach remains the original double heating Thellier protocol provided that natural remanence is controlled by pure magnetite with a narrow distribution of small grain sizes, mostly single domains. The presence of titanium, even in small amount generates biases which yield incorrect field values. Single domain grains frequently dominate the magnetization of glass samples, which explains the success of this selective approach. They are also present in volcanic lava flows but much less frequently, and therefore contribute to the low success rate of most experiments. However the loss of at least 70% of the magnetization at very high temperatures prior to the Curie point appears to be an essential prerequisite that increases the success rate to almost 100% and has been validated from historical flows and from recent studies. This requirement can easily be tested by thermal demagnetization while low temperature experiments can document the detection of single domain magnetite using the δFC/δZFC parameter as suggested (Moskowitz et al, 1993) for biogenic magnetite.

  13. Gyrokinetic Statistical Absolute Equilibrium and Turbulence

    SciTech Connect

    Jian-Zhou Zhu and Gregory W. Hammett

    2011-01-10

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence [T.-D. Lee, "On some statistical properties of hydrodynamical and magnetohydrodynamical fields," Q. Appl. Math. 10, 69 (1952)] is taken to study gyrokinetic plasma turbulence: A finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N + 1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  14. Climate Absolute Radiance and Refractivity Observatory (CLARREO)

    NASA Technical Reports Server (NTRS)

    Leckey, John P.

    2015-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is a mission, led and developed by NASA, that will measure a variety of climate variables with an unprecedented accuracy to quantify and attribute climate change. CLARREO consists of three separate instruments: an infrared (IR) spectrometer, a reflected solar (RS) spectrometer, and a radio occultation (RO) instrument. The mission will contain orbiting radiometers with sufficient accuracy, including on orbit verification, to calibrate other space-based instrumentation, increasing their respective accuracy by as much as an order of magnitude. The IR spectrometer is a Fourier Transform spectrometer (FTS) working in the 5 to 50 microns wavelength region with a goal of 0.1 K (k = 3) accuracy. The FTS will achieve this accuracy using phase change cells to verify thermistor accuracy and heated halos to verify blackbody emissivity, both on orbit. The RS spectrometer will measure the reflectance of the atmosphere in the 0.32 to 2.3 microns wavelength region with an accuracy of 0.3% (k = 2). The status of the instrumentation packages and potential mission options will be presented.

  15. Absolute flux measurements for swift atoms

    NASA Technical Reports Server (NTRS)

    Fink, M.; Kohl, D. A.; Keto, J. W.; Antoniewicz, P.

    1987-01-01

    While a torsion balance in vacuum can easily measure the momentum transfer from a gas beam impinging on a surface attached to the balance, this measurement depends on the accommodation coefficients of the atoms with the surface and the distribution of the recoil. A torsion balance is described for making absolute flux measurements independent of recoil effects. The torsion balance is a conventional taut suspension wire design and the Young modulus of the wire determines the relationship between the displacement and the applied torque. A compensating magnetic field is applied to maintain zero displacement and provide critical damping. The unique feature is to couple the impinging gas beam to the torsion balance via a Wood's horn, i.e., a thin wall tube with a gradual 90 deg bend. Just as light is trapped in a Wood's horn by specular reflection from the curved surfaces, the gas beam diffuses through the tube. Instead of trapping the beam, the end of the tube is open so that the atoms exit the tube at 90 deg to their original direction. Therefore, all of the forward momentum of the gas beam is transferred to the torsion balance independent of the angle of reflection from the surfaces inside the tube.

  16. 21 CFR 868.1760 - Volume plethysmograph.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Volume plethysmograph. 868.1760 Section 868.1760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... the patient's lung volume changes. (b) Classification. Class II (performance standards)....

  17. SU-C-210-01: Are Clinically Relevant Dosimetric Endpoints Significantly Better with Gating of Lung SBRT Vs. ITV-Based Treatment?: Results of a Large Cohort Investigation Analyzing Predictive Dosimetric Indicators as a Function of Tumor Volume and Motion Amplitude

    SciTech Connect

    Kim, J; Zhao, B; Ajlouni, M; Movsas, B; Chetty, I.J.

    2015-06-15

    Purpose: To quantitatively compare patient internal target volume (ITV)-based plans with retrospectively generated gated plans to evaluate potential dosimetric improvements in lung toxicity from gated radiotherapy. Methods: Evaluation was conducted for 150 stereotactic body radiation therapy (SBRT) treatment plans for 128 early-stage (T1–T3, <5cm) NSCLC patients. PTV margins were: ITV+5 mm (ITV-plan) and GTV+5 mm (Gated-plan). ITV-based and gated treatment plans were compared on the same free-breathing CT. ITV-based plan constraints were used to re-optimize and recalculate new gated plans. Plans were generated for 3 fractionation regimens: 3×18Gy, 4×12Gy (original), and 5×10Gy. Physical dose was converted to equivalent dose in 2Gy fractions (EQD2), which was used to determine mean lung dose (MLD) and percent volume of lung receiving ≥20Gy (V20). MLD and V20 differences between gating and ITV-based plans were analyzed as a function of both three-dimensional (3D) motion and tumor volume. The low dose region, V5, was also evaluated. Results: MLD and V20 differences between gated and ITV-based plans were larger for lower (1.48±1.32Gy and 1.44±1.29%) than for upper lobe tumors (0.89±0.74Gy and 0.92±0.71%) due to smaller tumor motion (2.9±3.4mm) compared to lower lobe tumors (8.1±6.1mm). Average differences of <1–2% were noted in V5 between ITV and gated plans. Dosimetric differences between gating and ITV-based methods increased with increasing tumor motion and decreasing tumor volume. Overall, average MLD (8.04±3.92Gy) and V20 (8.29±4.33%) values for ITV-based plans were already well below clinical guidelines, even for the 3×18Gy dose scheme, for which largest differences were noted relative to gated plans. Similar results were obtained for 5×10Gy and 4×12Gy regimens. Conclusion: Clinically relevant improvement in pulmonary toxicity, based on predictors of radiation pneumonitis (MLD and V20) was not generally observed, though improvement for tumors

  18. Pericardial Fat Is Associated With Impaired Lung Function and a Restrictive Lung Pattern in Adults

    PubMed Central

    Liu, Jiankang; Bidulescu, Aurelian; Burchfiel, Cecil M.; Taylor, Herman A.; Petrini, Marcy F.

    2011-01-01

    Background: Impaired lung function has been linked to obesity and systemic inflammation. Pericardial fat has been shown to be associated with anomalies in cardiac structure, function, and atherosclerosis. We hypothesized that pericardial fat may have a similar role in the impairment of lung function. Methods: Cross-sectional associations of pericardial fat volumes, quantified by multidetector CT scan, with FEV1 and FVC assessed by spirometry, were investigated in 1,293 participants (54.5 ± 10.8 years; 66.4% women) in the Jackson Heart Study. We also examined whether these associations were independent of visceral adipose tissue (VAT). Results: Pericardial fat was associated with impaired lung function after multivariable adjustment, but these associations generally did not remain after adjustment for VAT. An exception was the FEV1/FVC ratio. Higher pericardial fat volumes were associated with higher odds of a restrictive lung pattern and lower odds of airway obstruction. Participants in the highest quartile had the highest odds of a restrictive lung pattern (OR, 1.85; 95% CI, 1.22-2.79, compared with quartile 1), even after adjustment for VAT. The odds of obstruction decreased across increasing quartiles of pericardial fat. These relationships were generally graded, suggesting dose-response trends. Conclusions: Pericardial fat is generally associated with lower lung function and independently associated with a restrictive lung pattern in middle-aged and elderly adults. Further research is needed to fully understand the mechanisms through which pericardial fat contributes to pulmonary anomalies. PMID:21737489

  19. Stereology and morphometry of lung tissue.

    PubMed

    Mühlfeld, Christian; Knudsen, Lars; Ochs, Matthias

    2013-01-01

    This chapter deals with the stereological quantification of structural characteristics of the lung. The aim of design-based stereological methods is the unbiased and efficient estimation of structural features without making any assumptions on the underlying nature of the biological sample. The methods are based on rigorous sampling of location and orientation, the application of appropriate test systems, and the controlling of the precision of the estimates. Here, we describe the workflow from the fixation of the lung over the processing of the tissue samples to gaining estimates on the structural properties of the lung. Specifically, this chapter deals with methods for estimating the reference volume, sampling location, and sampling orientation, estimating volumes and surface areas of alveolar compartments, estimating total alveolar number, performing stereology at light and electron microscopic level, and dealing with technical problems such as tissue shrinkage. The procedures are illustrated using a worked example from the authors' own laboratory.

  20. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOEpatents

    Prasad, Mano K.; Snyderman, Neal J.; Rowland, Mark S.

    2015-12-01

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  1. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOEpatents

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  2. Positioning, alignment and absolute pointing of the ANTARES neutrino telescope

    NASA Astrophysics Data System (ADS)

    Fehr, F.; Distefano, C.; Antares Collaboration

    2010-01-01

    A precise detector alignment and absolute pointing is crucial for point-source searches. The ANTARES neutrino telescope utilises an array of hydrophones, tiltmeters and compasses for the relative positioning of the optical sensors. The absolute calibration is accomplished by long-baseline low-frequency triangulation of the acoustic reference devices in the deep-sea with a differential GPS system at the sea surface. The absolute pointing can be independently verified by detecting the shadow of the Moon in cosmic rays.

  3. Lung function in Pakistani wood workers.

    PubMed

    Meo, Sultan A

    2006-06-01

    The lung function impairment is the most common respiratory problem in industrial plants and their vicinity. Therefore, the purpose was to study the affects of wood dust and its duration of exposure on lung function. This was a matched cross-sectional study of Spirometry in 46 non-smoking wood workers with age range 20 - 60 years, who worked without the benefit of wood dust control ventilation or respiratory protective devices. Pulmonary function test was performed by using an electronic Spirometer. Significant reduction was observed in the mean values of Forced Vital Capacity (FVC), Forced Expiratory Volume in one second (FEV1), and Maximum Voluntary Ventilation (MVV) in wood workers relative to their matched controls. This impairment was increased with the duration of exposure to wood industries. It is concluded that lung function in wood workers is impaired and stratification of results shows a dose-response effect of years of wood dust exposure on lung function.

  4. Absolute and Convective Instability of a Liquid Jet

    NASA Technical Reports Server (NTRS)

    Lin, S. P.; Hudman, M.; Chen, J. N.

    1999-01-01

    The existence of absolute instability in a liquid jet has been predicted for some time. The disturbance grows in time and propagates both upstream and downstream in an absolutely unstable liquid jet. The image of absolute instability is captured in the NASA 2.2 sec drop tower and reported here. The transition from convective to absolute instability is observed experimentally. The experimental results are compared with the theoretical predictions on the transition Weber number as functions of the Reynolds number. The role of interfacial shear relative to all other relevant forces which cause the onset of jet breakup is explained.

  5. The Diabetic Lung - A New Target Organ?

    PubMed Central

    Pitocco, Dario; Fuso, Leonello; Conte, Emanuele G.; Zaccardi, Francesco; Condoluci, Carola; Scavone, Giuseppe; Incalzi, Raffaele Antonelli; Ghirlanda, Giovanni

    2012-01-01

    Several abnormalities of the respiratory function have been reported in patients with type 1 and type 2 diabetes. These abnormalities concern lung volume, pulmonary diffusing capacity, control of ventilation, bronchomotor tone, and neuroadrenergic bronchial innervation. Many hypotheses have emerged, and characteristic histological changes have been described in the "diabetic lung", which could explain this abnormal respiratory function. Given the specific abnormalities in diabetic patients, the lung could thus be considered as a target organ in diabetes. Although the practical implications of these functional changes are mild, the presence of an associated acute or chronic pulmonary and/or cardiac disease could determine severe respiratory derangements in diabetic patients. Another clinical consequence of the pulmonary involvement in diabetes is the accelerated decline in respiratory function. The rate of decline in respiratory function in diabetics has been found to be two-to-three times faster than in normal non-smoking subjects, as reported in longitudinal studies. This finding, together with the presence of anatomical and biological changes similar to those described in the aging lung, indicates that the "diabetic lung" could even be considered a model of accelerated aging. This review describes and analyses the current insight into the relationship of diabetes and lung disease, and suggests intensifying research into the lung as a possible target organ in diabetes. PMID:22972442

  6. The promise of microfluidic artificial lungs.

    PubMed

    Potkay, Joseph A

    2014-11-07

    Microfluidic or microchannel artificial lungs promise to enable a new class of truly portable, therapeutic artificial lungs through feature sizes and blood channel designs that closely mimic those found in their natural counterpart. These new artificial lungs could potentially: 1) have surface areas and priming volumes that are a fraction of current technologies thereby decreasing device size and reducing the foreign body response; 2) contain blood flow networks in which cells and platelets experience pressures, shear stresses, and branching angles that copy those in the human lung thereby improving biocompatibility; 3) operate efficiently with room air, eliminating the need for gas cylinders and complications associated with hyperoxemia; 4) exhibit biomimetic hydraulic resistances, enabling operation with natural pressures and eliminating the nee