Science.gov

Sample records for absolute perfusion values

  1. Easy Absolute Values? Absolutely

    ERIC Educational Resources Information Center

    Taylor, Sharon E.; Mittag, Kathleen Cage

    2015-01-01

    The authors teach a problem-solving course for preservice middle-grades education majors that includes concepts dealing with absolute-value computations, equations, and inequalities. Many of these students like mathematics and plan to teach it, so they are adept at symbolic manipulations. Getting them to think differently about a concept that they…

  2. Teaching Absolute Value Meaningfully

    ERIC Educational Resources Information Center

    Wade, Angela

    2012-01-01

    What is the meaning of absolute value? And why do teachers teach students how to solve absolute value equations? Absolute value is a concept introduced in first-year algebra and then reinforced in later courses. Various authors have suggested instructional methods for teaching absolute value to high school students (Wei 2005; Stallings-Roberts…

  3. Absolute realization of low BRDF value

    NASA Astrophysics Data System (ADS)

    Liu, Zilong; Liao, Ningfang; Li, Ping; Wang, Yu

    2010-10-01

    Low BRDF value is widespread used in many critical domains such as space and military fairs. These values below 0.1 Sr-1 . So the Absolute realization of these value is the most critical issue in the absolute measurement of BRDF. To develop the Absolute value realization theory of BRDF , defining an arithmetic operators of BRDF , achieving an absolute measurement Eq. of BRDF based on radiance. This is a new theory method to solve the realization problem of low BRDF value. This theory method is realized on a self-designed common double orientation structure in space. By designing an adding structure to extend the range of the measurement system and a control and processing software, Absolute realization of low BRDF value is achieved. A material of low BRDF value is measured in this measurement system and the spectral BRDF value are showed within different angles allover the space. All these values are below 0.4 Sr-1 . This process is a representative procedure about the measurement of low BRDF value. A corresponding uncertainty analysis of this measurement data is given depend on the new theory of absolute realization and the performance of the measurement system. The relative expand uncertainty of the measurement data is 0.078. This uncertainty analysis is suitable for all measurements using the new theory of absolute realization and the corresponding measurement system.

  4. A Conceptual Approach to Absolute Value Equations and Inequalities

    ERIC Educational Resources Information Center

    Ellis, Mark W.; Bryson, Janet L.

    2011-01-01

    The absolute value learning objective in high school mathematics requires students to solve far more complex absolute value equations and inequalities. When absolute value problems become more complex, students often do not have sufficient conceptual understanding to make any sense of what is happening mathematically. The authors suggest that the…

  5. Absolutely relative or relatively absolute: violations of value invariance in human decision making.

    PubMed

    Teodorescu, Andrei R; Moran, Rani; Usher, Marius

    2016-02-01

    Making decisions based on relative rather than absolute information processing is tied to choice optimality via the accumulation of evidence differences and to canonical neural processing via accumulation of evidence ratios. These theoretical frameworks predict invariance of decision latencies to absolute intensities that maintain differences and ratios, respectively. While information about the absolute values of the choice alternatives is not necessary for choosing the best alternative, it may nevertheless hold valuable information about the context of the decision. To test the sensitivity of human decision making to absolute values, we manipulated the intensities of brightness stimuli pairs while preserving either their differences or their ratios. Although asked to choose the brighter alternative relative to the other, participants responded faster to higher absolute values. Thus, our results provide empirical evidence for human sensitivity to task irrelevant absolute values indicating a hard-wired mechanism that precedes executive control. Computational investigations of several modelling architectures reveal two alternative accounts for this phenomenon, which combine absolute and relative processing. One account involves accumulation of differences with activation dependent processing noise and the other emerges from accumulation of absolute values subject to the temporal dynamics of lateral inhibition. The potential adaptive role of such choice mechanisms is discussed.

  6. Absolute Value Boundedness, Operator Decomposition, and Stochastic Media and Equations

    NASA Technical Reports Server (NTRS)

    Adomian, G.; Miao, C. C.

    1973-01-01

    The research accomplished during this period is reported. Published abstracts and technical reports are listed. Articles presented include: boundedness of absolute values of generalized Fourier coefficients, propagation in stochastic media, and stationary conditions for stochastic differential equations.

  7. Consistent set of nuclear parameters values for absolute INAA

    SciTech Connect

    Heft, R.E.

    1980-01-01

    Gamma spectral analysis of irradiated material can be used to determine absolute disintegration rates for specific radionuclides. These data, together with measured values for the thermal and epithermal neutron fluxes, and irradiation, cooling and counting time values, are all the experimental information required to do absolute Instrumental Neutron Activation Analysis. The calculations required to go from product photon emission rate to target nuclide amount depend upon values used for the thermal neutron capture cross-section, the resonance absorption integral, the half-life and photon branching ratios. Values for these parameters were determined by irradiating and analyzing a series of elemental standards. The results of these measurements were combined with values reported by other workers to arrive at a set of recommended values for the constants. Values for 114 nuclides are listed.

  8. Absolute Value Inequalities: High School Students' Solutions and Misconceptions

    ERIC Educational Resources Information Center

    Almog, Nava; Ilany, Bat-Sheva

    2012-01-01

    Inequalities are one of the foundational subjects in high school math curricula, but there is a lack of academic research into how students learn certain types of inequalities. This article fills part of the research gap by presenting the findings of a study that examined high school students' methods of approaching absolute value inequalities,…

  9. Standardized perfusion value: universal CT contrast enhancement scale that correlates with FDG PET in lung nodules.

    PubMed

    Miles, K A; Griffiths, M R; Fuentes, M A

    2001-08-01

    The standardized enhancement value and standardized perfusion value allow comparison between different methods for quantification of contrast enhancement during computed tomography (CT). Standard perfusion values calculated from CT measurements of perfusion within pulmonary nodules compared favorably with those derived from previously reported enhancement data and correlated with standardized uptake values obtained from positron emission tomographic images (r = 0.8, P <.01).

  10. Least absolute value state estimation with equality and inequality constraints

    SciTech Connect

    Abur, A. ); Celik, M.K. )

    1993-05-01

    A least absolute value (LAV) state estimator, which can handle both equality and inequality constraints on measurements, is developed. It is shown that, the use of equality constraints will actually reduce the number of Simplex iterations and thus the overall cpu time. The constraints can be used to enhance the reliability of the state estimator without affecting the computational efficiency of the estimator. The developed estimation program is tested using 14 through 1,000 bus power systems.

  11. Precision absolute value amplifier for a precision voltmeter

    DOEpatents

    Hearn, William E.; Rondeau, Donald J.

    1985-01-01

    Bipolar inputs are afforded by the plus inputs of first and second differential input amplifiers. A first gain determining resister is connected between the minus inputs of the differential amplifiers. First and second diodes are connected between the respective minus inputs and the respective outputs of the differential amplifiers. First and second FETs have their gates connected to the outputs of the amplifiers, while their respective source and drain circuits are connected between the respective minus inputs and an output lead extending to a load resister. The output current through the load resister is proportional to the absolute value of the input voltage difference between the bipolar input terminals. A third differential amplifier has its plus input terminal connected to the load resister. A second gain determining resister is connected between the minus input of the third differential amplifier and a voltage source. A third FET has its gate connected to the output of the third amplifier. The source and drain circuit of the third transistor is connected between the minus input of the third amplifier and a voltage-frequency converter, constituting an output device. A polarity detector is also provided, comprising a pair of transistors having their inputs connected to the outputs of the first and second differential amplifiers. The outputs of the polarity detector are connected to gates which switch the output of the voltage-frequency converter between up and down counting outputs.

  12. Precision absolute-value amplifier for a precision voltmeter

    DOEpatents

    Hearn, W.E.; Rondeau, D.J.

    1982-10-19

    Bipolar inputs are afforded by the plus inputs of first and second differential input amplifiers. A first gain determining resistor is connected between the minus inputs of the differential amplifiers. First and second diodes are connected between the respective minus inputs and the respective outputs of the differential amplifiers. First and second FETs have their gates connected to the outputs of the amplifiers, while their respective source and drain circuits are connected between the respective minus inputs and an output lead extending to a load resistor. The output current through the load resistor is proportional to the absolute value of the input voltage difference between the bipolar input terminals. A third differential amplifier has its plus input terminal connected to the load resistor. A second gain determining resistor is connected between the minus input of the third differential amplifier and a voltage source. A third FET has its gate connected to the output of the third amplifier. The source and drain circuit of the third transistor is connected between the minus input of the third amplifier and a voltage-frequency converter, constituting an output device. A polarity detector is also provided, comprising a pair of transistors having their inputs connected to the outputs of the first and second differential amplifiers. The outputs of the polarity detector are connected to gates which switch the output of the voltage-frequency converter between up and down counting outputs.

  13. A Special Application of Absolute Value Techniques in Authentic Problem Solving

    ERIC Educational Resources Information Center

    Stupel, Moshe

    2013-01-01

    There are at least five different equivalent definitions of the absolute value concept. In instances where the task is an equation or inequality with only one or two absolute value expressions, it is a worthy educational experience for learners to solve the task using each one of the definitions. On the other hand, if more than two absolute value…

  14. The Cauchy principal value and the Hadamard finite part integral as values of absolutely convergent integrals

    NASA Astrophysics Data System (ADS)

    Galapon, Eric A.

    2016-03-01

    The divergent integral ∫a b f ( x ) ( x - x 0 ) - n - 1 d x , for -∞ < a < x0 < b < ∞ and n = 0, 1, 2, …, is assigned, under certain conditions, the value equal to the simple average of the contour integrals ∫C±f(z)(z - x0)-n-1dz, where C+ (C-) is a path that starts from a and ends at b and which passes above (below) the pole at x0. It is shown that this value, which we refer to as the analytic principal value, is equal to the Cauchy principal value for n = 0 and to the Hadamard finite-part of the divergent integral for positive integer n. This implies that, where the conditions apply, the Cauchy principal value and the Hadamard finite-part integral are in fact values of absolutely convergent integrals. Moreover, it leads to the replacement of the boundary values in the Sokhotski-Plemelj-Fox theorem with integrals along some arbitrary paths. The utility of the analytic principal value in the numerical, analytical, and asymptotic evaluations of the principal value and the finite-part integral is discussed and demonstrated.

  15. Absolute value equations - what can we learn from their graphical representation?

    NASA Astrophysics Data System (ADS)

    Stupel, Moshe; Ben-Chaim, David

    2014-08-01

    Understanding graphical representations of algebraic equations, particularly graphical representations of absolute value equations, significantly improves students' mathematical comprehension and ignites within them an appreciation of the beauty and aesthetics of mathematics. In this paper, we focus on absolute value equations of linear and quadratic expressions, by examining various cases, presenting different methods of solving them by graphical representation, exhibiting the advantage of using dynamic software such as GeoGebra in solving them, and illustrating some examples of interesting graphical solutions. We recommend that teachers take advantage of the rapid development in technology to help learners tangibly visualize the solutions of absolute value equations before proceeding to the analytical solutions.

  16. Relation between regional myocardial uptake of /sup 82/Rb and perfusion: absolute reduction of cation uptake in ischemia

    SciTech Connect

    Selwyn, A.P.; Allan, R.M.; L'Abbate, A.; Horlock, P.; Camici, P.; Clark, J.; O'Brien, H.A.; Grant, P.M.

    1982-07-01

    Experiments were undertaken using /sup 82/Rb and position tomography to examine the relation between myocardial perfusion and cation uptake during acute ischemia. /sup 82/Rb was repeatedly eluted from a /sup 82/Sr-/sup 82/Rb generator. In six dogs emission tomograms were used to measure the delivered arterial and myocardial concentrations at rest and after coronary stenosis, stress and ischemia. There was a poor overall relation between regional myocardial uptake and flow measured by microspheres and a large individual variability. Extraction of /sup 82/Rb was inversely related to flow. Significant regional reduction of cation uptake was detected in the tomograms when regional flow decreased by more than 35 percent. This reduction was significantly greater when ischemia was present. A small but significantly greater when ischemia was present. A small but significant decrease (33.0 +/- 9.1 percent, mean +/- standard deviation) in the myocardial uptake of /sup 82/Rb was detected only when flow was increased by more than 120 percent in relation to a control area after administration of dypiridamole. The technique using /sup 82/Rb and tomography was applied in five volunteers and five patients with angina pectoris and coronary artery disease. Myocardial tomograms recorded at rest and after exercise in the volunteers showed homogeneous uptake of cation in reproducible and repeatable scans. In contrast, the patients with coronary artery disease showed an absolute mean decrease of 36 +/- 14 percent in regional myocardial uptake of /sup 82/Rb after exercise. These abnormalities persisted in serial tomograms for more than 20 minutes after the symptoms and electrocardiographic signs of ischemia.

  17. A special application of absolute value techniques in authentic problem solving

    NASA Astrophysics Data System (ADS)

    Stupel, Moshe

    2013-06-01

    There are at least five different equivalent definitions of the absolute value concept. In instances where the task is an equation or inequality with only one or two absolute value expressions, it is a worthy educational experience for learners to solve the task using each one of the definitions. On the other hand, if more than two absolute value expressions are involved, the definition that is most helpful is the one involving solving by intervals and evaluating critical points. In point of fact, application of this technique is one reason that the topic of absolute value is important in mathematics in general and in mathematics teaching in particular. We present here an authentic practical problem that is solved using absolute values and the 'intervals' method, after which the solution is generalized with surprising results. This authentic problem also lends itself to investigation using educational technological tools such as GeoGebra dynamic geometry software: mathematics teachers can allow their students to initially cope with the problem by working in an inductive environment in which they conduct virtual experiments until a solid conjecture has been reached, after which they should prove the conjecture deductively, using classic theoretical mathematical tools.

  18. Error analysis in newborn screening: can quotients support the absolute values?

    PubMed

    Arneth, Borros; Hintz, Martin

    2017-03-01

    Newborn screening is performed using modern tandem mass spectrometry, which can simultaneously detect a variety of analytes, including several amino acids and fatty acids. Tandem mass spectrometry measures the diagnostic parameters as absolute concentrations and produces fragments which are used as markers of specific substances. Several prominent quotients can also be derived, which are quotients of two absolute measured concentrations. In this study, we determined the precision of both the absolute concentrations and the derived quotients. First, the measurement error of the absolute concentrations and the measurement error of the ratios were practically determined. Then, the Gaussian theory of error calculation was used. Finally, these errors were compared with one another. The practical analytical accuracies of the quotients were significantly higher (e.g., coefficient of variation (CV) = 5.1% for the phenylalanine to tyrosine (Phe/Tyr) quotient and CV = 5.6% for the Fisher quotient) than the accuracies of the absolute measured concentrations (mean CVs = 12%). According to our results, the ratios are analytically correct and, from an analytical point of view, can support the absolute values in finding the correct diagnosis.

  19. Students' Mathematical Work on Absolute Value: Focusing on Conceptions, Errors and Obstacles

    ERIC Educational Resources Information Center

    Elia, Iliada; Özel, Serkan; Gagatsis, Athanasios; Panaoura, Areti; Özel, Zeynep Ebrar Yetkiner

    2016-01-01

    This study investigates students' conceptions of absolute value (AV), their performance in various items on AV, their errors in these items and the relationships between students' conceptions and their performance and errors. The Mathematical Working Space (MWS) is used as a framework for studying students' mathematical work on AV and the…

  20. A Multidimensional Approach to Explore the Understanding of the Notion of Absolute Value

    ERIC Educational Resources Information Center

    Gagatsis, Athanasios; Panaoura, Areti

    2014-01-01

    The study aimed to investigate students' conceptions on the notion of absolute value and their abilities in applying the specific notion in routine and non-routine situations. A questionnaire was constructed and administered to 17-year-old students. Data were analysed using the hierarchical clustering of variables and the implicative method, while…

  1. Maple (Computer Algebra System) in Teaching Pre-Calculus: Example of Absolute Value Function

    ERIC Educational Resources Information Center

    Tuluk, Güler

    2014-01-01

    Modules in Computer Algebra Systems (CAS) make Mathematics interesting and easy to understand. The present study focused on the implementation of the algebraic, tabular (numerical), and graphical approaches used for the construction of the concept of absolute value function in teaching mathematical content knowledge along with Maple 9. The study…

  2. Multislice Analysis of Blood Flow Values in CT Perfusion Studies of Lung Cancer

    PubMed Central

    Malavasi, Silvia; Barone, Domenico; Gavelli, Giampaolo

    2017-01-01

    Objectives. Tumour heterogeneity represents a key issue in CT perfusion (CTp), where all studies are usually based on global mean or median values of perfusion maps, often computed on whole tumour. We sought to determine whether, and to what extent, such global values can be representative of tumour heterogeneity, with respect to single slices, and could be used for therapy assessment. Materials and Methods. Twelve patients with one primary non-small cell lung cancer lesion were enrolled in this study, for a total amount of 26 CTp examinations and 118 slices. Mean and median blood flow (BF) values, calculated voxel-based, were computed on each slice and the whole tumour. To measure functional heterogeneity, entropy was calculated on BF values as well. Results. Most of the slices were not represented by the global BF values computed on the whole tumour. In addition, there are a number of lesions having equivalent global BF values, but they are composed of slices having very different heterogeneity distributions, that is, entropy values. Conclusions. Global mean/median BF values of the single slices separately should be considered for clinical assessment, only if interpreted through entropy computed on BF values. The numerical equivalence between global BF values of different lesions may correspond to different clinical status, thus inducing possible errors in choice of therapy when considering global values only. PMID:28164118

  3. Quantification of absolute myocardial perfusion at rest and during exercise with positron emission tomography after human cardiac transplantation

    SciTech Connect

    Krivokapich, J.; Stevenson, L.W.; Kobashigawa, J.; Huang, S.C.; Schelbert, H.R. )

    1991-08-01

    The maximal exercise capacity of cardiac transplant recipients is reduced compared with that of normal subjects. To determine if this reduced exercise capacity is related to inadequate myocardial perfusion during exercise, myocardial perfusion was measured noninvasively with use of positron emission tomography and nitrogen (N)-13 ammonia. Twelve transplant recipients with no angiographic evidence of accelerated coronary atherosclerosis were studied. Serial N-13 ammonia imaging was performed at rest and during supine bicycle exercise. The results were compared with those from 10 normal volunteers with a low probability of having cardiac disease. A two-compartment kinetic model for estimating myocardial perfusion was applied to the data. Transplant recipients achieved a significant lower exercise work load than did the volunteers (42 {plus minus} 16 vs. 128 {plus minus} 22 W), but a higher venous lactate concentration (31.3 {plus minus} 14.9 vs. 13.7 {plus minus} 4.1 mg/100 ml). Despite the difference in exercise work load, there was no significant difference in the cardiac work achieved by transplant recipients and normal subjects as evidenced by similar rate-pressure products of 24,000 {plus minus} 3,400 versus 21,300 {plus minus} 2,800 betas/min per mm Hg, respectively. In addition, myocardial blood flow during exercise was not significantly different between the two groups (1.70 {plus minus} 0.60 vs. 1.56 {plus minus} 0.71 ml/min per g, respectively). This study demonstrates that the myocardial flow response to the physiologic stress of exercise is appropriate in transplant recipients and does not appear to explain the decreased exercise capacity in these patients.

  4. The Impact of Different Absolute Solar Irradiance Values on Current Climate Model Simulations

    NASA Technical Reports Server (NTRS)

    Rind, David H.; Lean, Judith L.; Jonas, Jeffrey

    2014-01-01

    Simulations of the preindustrial and doubled CO2 climates are made with the GISS Global Climate Middle Atmosphere Model 3 using two different estimates of the absolute solar irradiance value: a higher value measured by solar radiometers in the 1990s and a lower value measured recently by the Solar Radiation and Climate Experiment. Each of the model simulations is adjusted to achieve global energy balance; without this adjustment the difference in irradiance produces a global temperature change of 0.48C, comparable to the cooling estimated for the Maunder Minimum. The results indicate that by altering cloud cover the model properly compensates for the different absolute solar irradiance values on a global level when simulating both preindustrial and doubled CO2 climates. On a regional level, the preindustrial climate simulations and the patterns of change with doubled CO2 concentrations are again remarkably similar, but there are some differences. Using a higher absolute solar irradiance value and the requisite cloud cover affects the model's depictions of high-latitude surface air temperature, sea level pressure, and stratospheric ozone, as well as tropical precipitation. In the climate change experiments it leads to an underestimation of North Atlantic warming, reduced precipitation in the tropical western Pacific, and smaller total ozone growth at high northern latitudes. Although significant, these differences are typically modest compared with the magnitude of the regional changes expected for doubled greenhouse gas concentrations. Nevertheless, the model simulations demonstrate that achieving the highest possible fidelity when simulating regional climate change requires that climate models use as input the most accurate (lower) solar irradiance value.

  5. Diagnostic Value of Dual-Source Computerized Tomography Combined with Perfusion Imaging for Peripheral Pulmonary Embolism

    PubMed Central

    Mao, Xijin; Wang, Shanshan; Jiang, Xingyue; Zhang, Lin; Xu, Wenjian

    2016-01-01

    Background Pulmonary embolism has become the third most common cardiovascular disease, which can seriously harm human health. Objectives To investigate the diagnostic value of dual-source computerized tomography (CT) and perfusion imaging for peripheral pulmonary embolism. Patients and Methods Thirty-two patients with suspected pulmonary embolism underwent dual-source CT exams. To compare the ability of pulmonary embolism detection software (PED) with CT pulmonary angiography (CTPA) in determining the presence, numbers, and locations of pulmonary emboli, the subsequent images were reviewed by two radiologists using both imaging modalities. Also, the diagnostic consistency between PED and CTPA images and dual-energy pulmonary perfusion imaging (DEPI) for segmental pulmonary embolism was compared. Results CTPA images revealed 50 (7.81%) segmental and 56 (4.38%) sub-segmental pulmonary embolisms, while the PED images showed 68 (10.63%) segmental and 94 (7.34%) sub-segmental pulmonary embolisms. Thus, the detection rate on PED images for peripheral pulmonary embolism was significantly higher than that of the CTPA images (P < 0.05). There was good consistency for diagnosing segmental pulmonary embolism between PED and CTPA and DEPI (kappa = 0.85). The sensitivity and specificity of DEPI images for the diagnosis of pulmonary embolism were 91.7% and 97.5%, respectively. Conclusion PED software of dual-source CT combined with perfusion imaging can significantly improve the detection rate of peripheral pulmonary embolism. PMID:27703656

  6. Absolute continuity for operator valued completely positive maps on C∗-algebras

    NASA Astrophysics Data System (ADS)

    Gheondea, Aurelian; Kavruk, Ali Şamil

    2009-02-01

    Motivated by applicability to quantum operations, quantum information, and quantum probability, we investigate the notion of absolute continuity for operator valued completely positive maps on C∗-algebras, previously introduced by Parthasarathy [in Athens Conference on Applied Probability and Time Series Analysis I (Springer-Verlag, Berlin, 1996), pp. 34-54]. We obtain an intrinsic definition of absolute continuity, we show that the Lebesgue decomposition defined by Parthasarathy is the maximal one among all other Lebesgue-type decompositions and that this maximal Lebesgue decomposition does not depend on the jointly dominating completely positive map, we obtain more flexible formulas for calculating the maximal Lebesgue decomposition, and we point out the nonuniqueness of the Lebesgue decomposition as well as a sufficient condition for uniqueness. In addition, we consider Radon-Nikodym derivatives for absolutely continuous completely positive maps that, in general, are unbounded positive self-adjoint operators affiliated to a certain von Neumann algebra, and we obtain a spectral approximation by bounded Radon-Nikodym derivatives. An application to the existence of the infimum of two completely positive maps is indicated, and formulas in terms of Choi's matrices for the Lebesgue decomposition of completely positive maps in matrix algebras are obtained.

  7. Accuracy, Precision, Sensitivity, and Specificity of Noninvasive ICP Absolute Value Measurements.

    PubMed

    Krakauskaite, Solventa; Petkus, Vytautas; Bartusis, Laimonas; Zakelis, Rolandas; Chomskis, Romanas; Preiksaitis, Aidanas; Ragauskas, Arminas; Matijosaitis, Vaidas; Petrikonis, Kestutis; Rastenyte, Daiva

    2016-01-01

    An innovative absolute intracranial pressure (ICP) value measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler (TCD) technology and uses intracranial and extracranial segments of the ophthalmic artery as pressure sensors. The ophthalmic artery is used as a natural pair of "scales" that compares ICP with controlled pressure Pe, which is externally applied to the orbit. To balance the scales, ICP = Pe a special two-depth TCD device was used as a pressure balance indicator. The proposed method is the only noninvasive ICP measurement method that does not need patient-specific calibration.

  8. Digital controller design for absolute value function constrained nonlinear systems via scalar sign function approach.

    PubMed

    Wu, Jian; Singla, Mithun; Olmi, Claudio; Shieh, Leang S; Song, Gangbing

    2010-07-01

    In this paper, a scalar sign function-based digital design methodology is developed for modeling and control of a class of analog nonlinear systems that are restricted by the absolute value function constraints. As is found to be not uncommon, many real systems are subject to the constraints which are described by the non-smooth functions such as absolute value function. The non-smooth and nonlinear nature poses significant challenges to the modeling and control work. To overcome these difficulties, a novel idea proposed in this work is to use a scalar sign function approach to effectively transform the original nonlinear and non-smooth model into a smooth nonlinear rational function model. Upon the resulting smooth model, a systematic digital controller design procedure is established, in which an optimal linearization method, LQR design and digital implementation through an advanced digital redesign technique are sequentially applied. The example of tracking control of a piezoelectric actuator system is utilized throughout the paper for illustrating the proposed methodology.

  9. A multidimensional approach to explore the understanding of the notion of absolute value

    NASA Astrophysics Data System (ADS)

    Gagatsis, Athanasios; Panaoura, Areti

    2014-02-01

    The study aimed to investigative students' conceptions on the notion of absolute value and their abilities in applying the specific notion in routine and non-routine situations. A questionnaire was constructed and administered to 17-year-old students. Data were analysed using the hierarchical clustering of variables and the implicative method, while the qualitative approach was used to identify and analyse students' errors. The results revealed students' strong tendency to use algorithmic processes even in situations in which this kind of reasoning was not suited. This tendency and students' errors in the tasks were assumed to occur primarily due to obstacles of didactic origin concerning the didactic contract and subsequently due to epistemological obstacles grounded in the history of mathematics.

  10. Pulse perfusion value predicts eye opening after sevoflurane anaesthesia: an explorative study.

    PubMed

    Enekvist, Bruno; Johansson, Anders

    2015-08-01

    The variables measured in modern pulse oximetry apparatuses include a graphical pulse curve and a specified perfusion value (PV) that could be a sensitive marker for detecting differences in sympathetic activity. We hypothesized that there is a correlation between a reduction of PV and the time to eye opening after general anaesthesia. The objective was to investigate whether PV can predict eye opening after sevoflurane anaesthesia. Prospective, explorative clinical study included 20 patients, ASA physical status 1 or 2, at Skåne University Hospital, Lund, Sweden, from November 2012 to January 2013 scheduled for elective breast tumour surgery. A general anaesthesia was delivered with inhalation of oxygen, nitrous oxide and sevoflurane anaesthesia to a depth of 1.2 minimal alveolar concentration. Sevoflurane inspiratory and expiratory concentrations were measured. Bispectral index monitoring, PV as measured by pulse oximeter, heart rate and carbon dioxide were registered at before anaesthesia, 15 min after induction (at 1.2 minimal alveolar concentration), at end of surgery and at eye opening at the end of anaesthesia. PV values were lower before anaesthesia and at eye opening compared to at 15 min after induction and at end of surgery (P < 0.05). The reduction of PV between end of surgery and eye opening was 0.76. We conclude that the pulse oximeter PV could be a useful variable to assess the timing of recovery, in terms of eye opening after a general anaesthesia.

  11. The value of 64-slice spiral CT perfusion imaging in the treatment of liver cancer with argon-helium cryoablation

    PubMed Central

    Lv, Yinggang; Jin, Yurong; Yan, Qiaohuan; Yuan, Dingling; Wang, Yanling; Li, Xianping; Shen, Yanfeng

    2016-01-01

    We analyzed the effectiveness of using 64-slice spiral computed tomography (CT) and perfusion imaging to guide argon-helium cryoablation treatment of liver cancer. In total, 60 cases of advanced hepatocellular carcinoma before surgery treated with argon-helium cryoablation were inlcuded in the present study. Retrospective summary of the 60 cases of metaphase and advanced liver cancer were used as the control group. The control group were treated using cryoablation with argon-helium knife. We used enhanced scanning with 64-slice spiral CT to define the extent of their lesions and prepared a plan of percutaneous cryoablation for the treatment. Intraoperatively, we used the dynamics of CT perfusion imaging to observe the frozen ablation range and decreased the rate of complications. After surgery, the patients were followed-up regularly by 64-slice CT. We used conventional X-ray, CT and magnetic resonance imaging (MRI) for pre-operative lateralization. Intraoperative X-ray or ultrasound guidance and follow-up with CT or MTI were added to determine the clinical effectiveness and prognosis. The results showed that the total effective rate was improved significantly and incidence rate of overall complications decreased markedly in the observation group. Following treatment, AFP decreased significantly while the total freezing area and time were reduced significantly. The median survival time was increased significantly in the observation group. The numeric values of hepatic arterial perfusion, portal vein perfusion and hepatic arterial perfusion index were all markedly lowered after treatment. Differences were statistically significant (P<0.05). In conclusion, the use of 64-slice spiral CT perfusion imaging may considerably improve the effects of liver cancer treatment using the argon-helium cryoablation. It extended the survival time and reduced complications. PMID:28105165

  12. Prospective Teachers' Reactions to "Right-or-Wrong" Tasks: The Case of Derivatives of Absolute Value Functions

    ERIC Educational Resources Information Center

    Tsamir, Pessia; Rasslan, Shaker; Dreyfus, Tommy

    2006-01-01

    This paper illustrates the role of a "Thinking-about-Derivatives" task in identifying learners' derivative conceptions and for promoting their critical thinking about derivatives of absolute value functions. The task included three parts: "Define" the derivative of a function f(x) at x = x[subscript 0], "Solve-if-Possible" the derivative of f(x) =…

  13. Delta Procalcitonin Is a Better Indicator of Infection Than Absolute Procalcitonin Values in Critically Ill Patients: A Prospective Observational Study

    PubMed Central

    Hankovszky, Péter; Hajdú, Edit

    2016-01-01

    Purpose. To investigate whether absolute value of procalcitonin (PCT) or the change (delta-PCT) is better indicator of infection in intensive care patients. Materials and Methods. Post hoc analysis of a prospective observational study. Patients with suspected new-onset infection were included in whom PCT, C-reactive protein (CRP), temperature, and leukocyte (WBC) values were measured on inclusion (t0) and data were also available from the previous day (t−1). Based on clinical and microbiological data, patients were grouped post hoc into infection- (I-) and noninfection- (NI-) groups. Results. Of the 114 patients, 85 (75%) had proven infection. PCT levels were similar at t−1: I-group (median [interquartile range]): 1.04 [0.40–3.57] versus NI-group: 0.53 [0.16–1.68], p = 0.444. By t0 PCT levels were significantly higher in the I-group: 4.62 [1.91–12.62] versus 1.12 [0.30–1.66], p = 0.018. The area under the curve to predict infection for absolute values of PCT was 0.64 [95% CI = 0.52–0.76], p = 0.022; for percentage change: 0.77 [0.66–0.87], p < 0.001; and for delta-PCT: 0.85 [0.78–0.92], p < 0.001. The optimal cut-off value for delta-PCT to indicate infection was 0.76 ng/mL (sensitivity 80 [70–88]%, specificity 86 [68-96]%). Neither absolute values nor changes in CRP, temperature, or WBC could predict infection. Conclusions. Our results suggest that delta-PCT values are superior to absolute values in indicating infection in intensive care patients. This trial is registered with ClinicalTrials.gov identifier: NCT02311816. PMID:27597981

  14. Prognostic value of thallium-201 perfusion defects in idiopathic dilated cardiomyopathy

    SciTech Connect

    Doi, Y.L.; Chikamori, T.; Tukata, J.; Yonezawa, Y.; Poloniecki, J.D.; Ozawa, T.; McKenna, W.J. )

    1991-01-15

    To assess the prognostic significance of thallium-201 perfusion defects in patients with idiopathic dilated cardiomyopathy (IDC), 43 patients underwent thallium scintigraphy in addition to clinical, echocardiographic, angiographic and hemodynamic evaluation. Eleven patients had no significant thallium perfusion abnormality, 19 had multiple small defects and 13 had a large defect. During 3.2 +/- 2.2 years, 14 patients had disease-related mortality. The patients who died had a higher incidence of ventricular tachycardia (71 vs 31%; p less than 0.02), increased cardiothoracic ratio (60 +/- 6 vs 54 +/- 6; p = 0.005), decreased fractional shortening (11 +/- 6 vs 15 +/- 5; p less than 0.05), increased pulmonary wedge pressure (15 +/- 7 vs 10 +/- 6 mm Hg; p = 0.05), increased left ventricular end-diastolic pressure (21 +/- 8 vs 14 +/- 6 mm Hg; p = 0.02) and abnormal thallium perfusion defects (13 of 14 vs 16 of 26; p less than 0.05) compared with survivors. Age, gender, left ventricular end-systolic and end-diastolic dimensions, cardiac index and ejection fraction were not statistically different in the survivors versus the patients who died. Kaplan-Meier survival estimates at 1, 3 and 5 years were 100% in patients without significant perfusion abnormality; 89, 77 and 64%, respectively, in patients with multiple small defects; and 84, 76 and 30%, respectively, in patients with a large defect (p less than 0.025 by log rank test).

  15. Calculation of absolute free energy of binding for theophylline and its analogs to RNA aptamer using nonequilibrium work values

    NASA Astrophysics Data System (ADS)

    Tanida, Yoshiaki; Ito, Masakatsu; Fujitani, Hideaki

    2007-08-01

    The massively parallel computation of absolute binding free energy with a well-equilibrated system (MP-CAFEE) has been developed [H. Fujitani, Y. Tanida, M. Ito, G. Jayachandran, C.D. Snow, M.R. Shirts, E.J. Sorin, V.S. Pande, J. Chem. Phys. 123 (2005) 084108]. As an application, we perform the binding affinity calculations of six theophylline-related ligands with RNA aptamer. Basically, our method is applicable when using many compute nodes to accelerate simulations, thus a parallel computing system is also developed. To further reduce the computational cost, the adequate non-uniform intervals of coupling constant λ, connecting two equilibrium states, namely bound and unbound, are determined. The absolute binding energies Δ G thus obtained have effective linear relation between the computed and experimental values. If the results of two other different methods are compared, thermodynamic integration (TI) and molecular mechanics Poisson-Boltzmann surface area (MM-PBSA) by the paper of Gouda et al. [H. Gouda, I.D. Kuntz, D.A. Case, P.A. Kollman, Biopolymers 68 (2003) 16], the predictive accuracy of the relative values ΔΔ G is almost comparable to that of TI: the correlation coefficients ( R) obtained are 0.99 (this work), 0.97 (TI), and 0.78 (MM-PBSA). On absolute binding energies meanwhile, a constant energy shift of ˜-7 kcal/mol against the experimental values is evident. To solve this problem, several presumable reasons are investigated.

  16. Histogram Analysis of CT Perfusion of Hepatocellular Carcinoma for Predicting Response to Transarterial Radioembolization: Value of Tumor Heterogeneity Assessment

    SciTech Connect

    Reiner, Caecilia S. Gordic, Sonja; Puippe, Gilbert; Morsbach, Fabian; Wurnig, Moritz; Schaefer, Niklaus; Veit-Haibach, Patrick; Pfammatter, Thomas; Alkadhi, Hatem

    2016-03-15

    PurposeTo evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE).Materials and MethodsSixteen patients (15 male; mean age 65 years; age range 47–80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters’ ability to discriminate responders from non-responders.ResultsAccording to mRECIST, 8 patients (50 %) were responders and 8 (50 %) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min{sup −1} 100 mL{sup −1}); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min{sup −1} 100 mL{sup −1}; p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min{sup −1} 100 mL{sup −1}, therapy response could be predicted with a sensitivity of 88 % (7/8) and specificity of 75 % (6/8).ConclusionVoxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.

  17. An absolute determination of the 14O ( β+) Fermi decay Q-value

    NASA Astrophysics Data System (ADS)

    White, R. E.; Naylor, H.; Barker, P. H.; Lovelock, D. M. J.; Smythe, R. M.

    1981-10-01

    The threshold energy for the reaction 14N(p, n) 14O has been determined to be 6353.02±0.08keV, yielding a corresponding energy release of 1808.25±0.10keV for the superallowed 14O decay. Using recent half-life values an ƒ Rt- value of 3084.4±1.1 s. is obtained for this decay.

  18. Advances in the Metrology of Absolute Value Assignments to Isotopic Reference Materials: Consequences from the Avogadro Project

    NASA Astrophysics Data System (ADS)

    Vocke, Robert; Rabb, Savelas

    2015-04-01

    All isotope amount ratios (hereafter referred to as isotope ratios) produced and measured on any mass spectrometer are biased. This unfortunate situation results mainly from the physical processes in the source area where ions are produced. Because the ionized atoms in poly-isotopic elements have different masses, such processes are typically mass dependent and lead to what is commonly referred to as mass fractionation (for thermal ionization and electron impact sources) and mass bias (for inductively coupled plasma sources.) This biasing process produces a measured isotope ratio that is either larger or smaller than the "true" ratio in the sample. This has led to the development of numerous fractionation "laws" that seek to correct for these effects, many of which are not based on the physical processes giving rise to the biases. The search for tighter and reproducible precisions has led to two isotope ratio measurement systems that exist side-by-side. One still seeks to measure "absolute" isotope ratios while the other utilizes an artifact based measurement system called a delta-scale. The common element between these two measurement systems is the utilization of isotope reference materials (iRMs). These iRMs are used to validate a fractionation "law" in the former case and function as a scale anchor in the latter. Many value assignments of iRMs are based on "best measurements" by the original groups producing the reference material, a not entirely satisfactory approach. Other iRMs, with absolute isotope ratio values, have been produced by calibrated measurements following the Atomic Weight approach (AW) pioneered by NBS nearly 50 years ago. Unfortunately, the AW is not capable of calibrating the new generation of iRMs to sufficient precision. So how do we get iRMs with isotope ratios of sufficient precision and without bias? Such a focus is not to denigrate the extremely precise delta-scale measurements presently being made on non-traditional and tradition

  19. Prediction of Absolute Hydroxyl pKa Values for 3-Hydroxypyridin-4-ones.

    PubMed

    Chen, Yu-Lin; Doltsinis, Nikos L; Hider, Robert C; Barlow, Dave J

    2012-10-18

    pKa values have been calculated for a series of 3-hydroxypyridin-4-one (HPO) chelators in aqueous solution using coordination constrained ab initio molecular dynamics (AIMD) in combination with thermodynamic integration. This dynamics-based methodology in which the solvent is treated explicitly at the ab initio level has been compared with more commonly used simple, static, approaches. Comparison with experimental numbers has confirmed that the AIMD-based approach predicts the correct trend in the pKa values and produces the lowest average error (∼0.3 pKa units). The corresponding pKa predictions made via static quantum mechanical calculations overestimate the pKa values by 0.3-7 pKa units, with the extent of error dependent on the choice of thermodynamic cycle employed. The use of simple quantitative structure property relationship methods gives prediction errors of 0.3-1 pKa units, with some values overestimated and some underestimated. Beyond merely calculating pKa values, the AIMD simulations provide valuable additional insight into the atomistic details of the proton transfer mechanism and the solvation structure and dynamics at all stages of the reaction. For all HPOs studied, it is seen that proton transfer takes place along a chain of three H2O molecules, although direct hydrogen bonds are seen to form transiently. Analysis of the solvation structure before and after the proton transfer event using radial pair distribution functions and integrated number densities suggests that the trends in the pKa values correlate with the strength of the hydrogen bond and the average number of solvent molecules in the vicinity of the donor oxygen.

  20. Evaluation of a proper cutoff value on quantitative dual-energy perfusion CT for the assessment of acute pulmonary thromboembolism.

    PubMed

    Kunihiro, Yoshie; Okada, Munemasa; Matsunaga, Naofumi

    2017-01-01

    Background The cutoff value for assessing the severity of acute pulmonary thromboembolism (PTE) using relative volumetric evaluations of dual-energy perfusion computed tomography (DEpCT) is unclear. Purpose To determine the proper cutoff value for determining the severity of PTE using DEpCT volumetry. Material and Methods A total of 185 patients with venous thromboembolism were included in this study, of whom 61 were diagnosed with acute PTE. DEpCT images were three-dimensionally reconstructed at the following attenuation ranges: 1-2 HU (V2), 1-10 HU (V10), and 1-120 HU (V120). The ratios of low perfusion areas associated with each threshold range per V120 were also calculated, and the relative ratios were expressed as %V2 to %V10. These values were compared with factors indicating the severity of PTE, including the pulmonary arterial pressure, heart rate, CT angiographic obstruction index (CTOI), and right/left ventricular diameter ratio (RV/LV). Results The area under the curve (AUC) of %V2 was highest (0.783) among these values (95% confidence interval, 0.710-0.856) based on the presence of IPCs. The %V2 showed moderate correlations with CTOI (r = 0.36, P = 0.005) and RV/LV (r = 0.36, P = 0.004) in the patients with acute PTE. Conclusion Volumetric evaluations of DEpCT images using the lowest attenuation threshold range (1-2 HU) exhibit the best correlation with factors suggesting the severity of acute PTE.

  1. Predicting Absolute Risk of Type 2 Diabetes Using Age and Waist Circumference Values in an Aboriginal Australian Community

    PubMed Central

    2015-01-01

    Objectives To predict in an Australian Aboriginal community, the 10-year absolute risk of type 2 diabetes associated with waist circumference and age on baseline examination. Method A sample of 803 diabetes-free adults (82.3% of the age-eligible population) from baseline data of participants collected from 1992 to 1998 were followed-up for up to 20 years till 2012. The Cox-proportional hazard model was used to estimate the effects of waist circumference and other risk factors, including age, smoking and alcohol consumption status, of males and females on prediction of type 2 diabetes, identified through subsequent hospitalisation data during the follow-up period. The Weibull regression model was used to calculate the absolute risk estimates of type 2 diabetes with waist circumference and age as predictors. Results Of 803 participants, 110 were recorded as having developed type 2 diabetes, in subsequent hospitalizations over a follow-up of 12633.4 person-years. Waist circumference was strongly associated with subsequent diagnosis of type 2 diabetes with P<0.0001 for both genders and remained statistically significant after adjusting for confounding factors. Hazard ratios of type 2 diabetes associated with 1 standard deviation increase in waist circumference were 1.7 (95%CI 1.3 to 2.2) for males and 2.1 (95%CI 1.7 to 2.6) for females. At 45 years of age with baseline waist circumference of 100 cm, a male had an absolute diabetic risk of 10.9%, while a female had a 14.3% risk of the disease. Conclusions The constructed model predicts the 10-year absolute diabetes risk in an Aboriginal Australian community. It is simple and easily understood and will help identify individuals at risk of diabetes in relation to waist circumference values. Our findings on the relationship between waist circumference and diabetes on gender will be useful for clinical consultation, public health education and establishing WC cut-off points for Aboriginal Australians. PMID:25876058

  2. Diagnostic value of IL-6, CRP, WBC, and absolute neutrophil count to predict serious bacterial infection in febrile infants.

    PubMed

    Zarkesh, Marjaneh; Sedaghat, Fatemeh; Heidarzadeh, Abtin; Tabrizi, Manizheh; Bolooki-Moghadam, Kobra; Ghesmati, Soheil

    2015-07-01

    Since clinical manifestations of most febrile infants younger than three months old are nonspecific, differentiation of Serious Bacterial Infection (SBI) from self-limiting viral illness is a significant challenge for pediatricians. This study was performed to assess the diagnostic value of white blood cell count (WBC), Absolute Neutrophil Count (ANC), Interleukin -6 (IL-6) and C-reactive protein (CRP) level to predict SBI in febrile infants younger than three months old who were hospitalized. This was a diagnostic test validation study. In this prospective study, 195 febrile infants admitted to 17 Shahrivar Hospital underwent a full sepsis workup including blood, urine, cerebrospinal fluid cultures and chest radiography. WBC count, ANC and CRP and Il-6 level were measured in all patients. Serum IL-6 concentration was measured by Enzyme-linked Immunosorbent Assay test. Then diagnostic, values of these tests for predicting SBI was compared with each other. Of total cases, 112 (57.4%) infants were male. SBI was diagnosed in 29 (14.9%) patients. The most common type of SBI was Urinary Tract Infection (UTI). Serum IL-6 (³20pg/dl) had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 79/1%, 91.6%,75.4%, 60.3%, respectively and for CRP (³ 10mg/l) values were 81.6%, 89.8%, 78.2%, and 52%,respectively. The predictive values of CRP and IL-6 were higher than WBC and ANC. IL-6 and CRP are more valid and better diagnostic markers for predicting SBI than WBC count and ANC. CRP level seems to be an accessible and cost-effective marker for early diagnosis of SBI. Since by no marker we can totally rule out SBI in febrile infants < three months of age, it is recommended to administer systemic antibiotics until culture results become available.

  3. Reducing the Standard Deviation in Multiple-Assay Experiments Where the Variation Matters but the Absolute Value Does Not

    PubMed Central

    Echenique-Robba, Pablo; Nelo-Bazán, María Alejandra; Carrodeguas, José A.

    2013-01-01

    When the value of a quantity for a number of systems (cells, molecules, people, chunks of metal, DNA vectors, so on) is measured and the aim is to replicate the whole set again for different trials or assays, despite the efforts for a near-equal design, scientists might often obtain quite different measurements. As a consequence, some systems’ averages present standard deviations that are too large to render statistically significant results. This work presents a novel correction method of a very low mathematical and numerical complexity that can reduce the standard deviation of such results and increase their statistical significance. Two conditions are to be met: the inter-system variations of matter while its absolute value does not, and a similar tendency in the values of must be present in the different assays (or in other words, the results corresponding to different assays must present a high linear correlation). We demonstrate the improvements this method offers with a cell biology experiment, but it can definitely be applied to any problem that conforms to the described structure and requirements and in any quantitative scientific field that deals with data subject to uncertainty. PMID:24205158

  4. Cross-sensory mapping of feature values in the size-brightness correspondence can be more relative than absolute.

    PubMed

    Walker, Laura; Walker, Peter

    2016-01-01

    A role for conceptual representations in cross-sensory correspondences has been linked to the relative (context-sensitive) mapping of feature values, whereas a role for sensory-perceptual representations has been linked to their absolute (context-insensitive) mapping. Demonstrating the relative nature of the automatic mapping underlying a cross-sensory correspondence therefore offers one way of confirming its conceptual basis. After identifying several prerequisites for relative and absolute mappings, we provide the first compelling demonstration that an automatically induced congruity effect based on a cross-sensory correspondence (i.e., that between haptic size and visual brightness) can be largely contingent on the relative mapping of the 2 features, thereby implying a conceptual basis for the correspondence. Participants in a speeded classification task were faster to classify a visual stimulus as brighter or darker when this required them to press a hidden response key that, incidentally, was relatively small or big, respectively. Importantly, the same levels of brightness (Experiment 1) and key size (Experiment 2) at different times corresponded to contrasting levels of the other feature depending on the context provided by the alternative stimuli with which they appeared. For example, the same medium key was congruent with a brighter stimulus when paired with a bigger key, but was congruent with a darker stimulus when paired with a smaller key. Reflecting on the broader implications of this finding, it is noted that the involvement of cross-sensory correspondences in some forms of sound symbolism in language also requires the relative coding of stimulus features.

  5. Generalized approach for using unbiased symmetric metrics with negative values: normalized mean bias factor and normalized mean absolute error factor

    EPA Science Inventory

    Unbiased symmetric metrics provide a useful measure to quickly compare two datasets, with similar interpretations for both under and overestimations. Two examples include the normalized mean bias factor and normalized mean absolute error factor. However, the original formulations...

  6. Hepatic perfusion abnormalities during treatment with hepatic arterial infusion chemotherapy: Value of CT arteriography using an implantable port system

    SciTech Connect

    Seki, Hiroshi; Kimura, Motomasa; Kamura, Takeshi; Miura, Tsutomu

    1996-05-01

    The purpose of this study was to evaluate CT arteriography (CTA) using an implantable port system in the detection of perfusion abnormalities occurring during hepatic arterial infusion chemotherapy (HAIC). In 51 patients with unresectable primary and metastatic liver tumors, who had implanted port systems for HAIC, CTA examinations through the infusion pump were performed. When perfusion abnormalities were found, selective angiography and/or digital subtraction angiography using the implantable port system were performed to determine the etiology. Forty-nine perfusion abnormalities were detected in 32 patients. Intrahepatic hypoperfusion was found in 24 cases. Of 11 patients in whom correction of the hypoperfusion was attempted, it was successful in 10. Of 13 patients in whom correction was not attempted, 6 patients showed progressive disease in nonperfused areas. Intrahepatic hyperperfusion was found in 14 cases, which showed no subsequent complication. Extrahepatic perfusion was found in 11 cases. We consider CTA to be useful in detecting perfusion abnormalities that may compromise HAIC. 22 refs., 3 figs., 3 tabs.

  7. Perfusion computed tomography imaging of abdominal aortic aneurysms may be of value for patient specific rupture risk estimation.

    PubMed

    Kontopodis, Nikolaos; Galanakis, Nikolaos; Tsetis, Dimitrios; Ioannou, Christos V

    2017-04-01

    Abdominal aortic aneurysm (AAA) continues to pose a significant cause of unexpected mortality in the developed countries with its incidence constantly rising. The indication of elective surgical repair is currently based on the maximum diameter and growth rate criteria which represent an oversimplification of the Law of Laplace stating that the stress exerted in a cylinder or sphere is proportional to its radius. These criteria fail to capture the complex pathophysiology of the aneurismal disease thus often leading to therapeutic inaccuracies (treating large AAAs with a very low actual rupture risk while observing smaller ones with a much greater risk). Aneurysmal disease is mainly a degenerative process leading to loss of structural integrity of the diseased aortic wall which cannot withhold the stresses due to systemic pressurization. Moreover aortic wall degeneration has been shown to be a localized phenomenon and rupture depends on the pointwise comparison of strength and stress rather than a global aortic wall weakening. Ex-vivo mechanical studies have related vessel wall hypoxia to loss of structural endurance and reduced wall strength. Therefore a module to capture in vivo variation of aortic wall blood supply and oxygenation would be of value for the evaluation of AAA rupture risk. Perfusion computed tomography (PCT) imaging represents a novel technique which has been already used to estimate tissue vascularity in several clinical conditions but not aneurismal disease. We hypothesize that PCT could be used as an adjunct tool during AAA diagnostics in order to evaluate aortic wall oxygenation in vivo, therefore providing a possible means to identify weak spots making the lesion amenable to rupture.

  8. Difference in the value of arterial and end-tidal carbon dioxide tension according to different surgical positions: Does it reliably reflect ventilation-perfusion mismatch?

    PubMed Central

    Joo, Jin; Kim, Young Hee; Choi, Jong Ho

    2012-01-01

    Background Body posture, as a gravitational factor, has a clear impact on pulmonary ventilation and perfusion. In lung units with mismatched ventilation and perfusion, gas exchange and/or elimination of carbon dioxide can be impaired. In this situation, differences in the value of arterial and end-tidal carbon dioxide tension [Δ(PaCO2 - PETCO2)] are expected to increase. This study was conducted to observe how Δ(PaCO2 - PETCO2) changed according to the 3 different surgical positions, and to determine whether Δ(PaCO2 - PETCO2) is a reliable predictor of ventilation/perfusion mismatch when a patient is in different postural positions. Methods Fifty-nine patients were divided into either the chronic obstructive pulmonary disease (COPD) group (n = 29) or the non-COPD group (n = 30). PaCO2 and PETCO2 were measured during surgery in the supine, prone, and lateral decubitus positions after a 10 minute stabilization period. The Δ(PaCO2 - PETCO2) were calculated and compared among positions. Results The Δ(PaCO2 - PETCO2) decreased slightly in the prone position and increased significantly in the lateral decubitus position compared with the supine position in both groups. These patterns almost corresponded with the degree of ventilation/perfusion mismatch from the results of the radiological studies. The Δ(PaCO2 - PETCO2) in the COPD group was significantly greater than that in the non-COPD group at all surgical positions. Conclusions Lateral decubitus position is associated with marked increase in Δ(PaCO2 - PETCO2), especially in patients with COPD. The Δ(PaCO2 - PETCO2) is a simple and reliable indicator to predict ventilation/perfusion mismatch at different surgical positions in patients with or without COPD. PMID:23060977

  9. Measurement of the B-->pi l nu branching fraction and determination of absolute value of V(ub) with tagged B mesons.

    PubMed

    Aubert, B; Barate, R; Bona, M; Boutigny, D; Couderc, F; Karyotakis, Y; Lees, J P; Poireau, V; Tisserand, V; Zghiche, A; Grauges, E; Palano, A; Chen, J C; Qi, N D; Rong, G; Wang, P; Zhu, Y S; Eigen, G; Ofte, I; Stugu, B; Abrams, G S; Battaglia, M; Brown, D N; Button-Shafer, J; Cahn, R N; Charles, E; Gill, M S; Groysman, Y; Jacobsen, R G; Kadyk, J A; Kerth, L T; Kolomensky, Yu G; Kukartsev, G; Lynch, G; Mir, L M; Orimoto, T J; Pripstein, M; Roe, N A; Ronan, M T; Wenzel, W A; del Amo Sanchez, P; Barrett, M; Ford, K E; Harrison, T J; Hart, A J; Hawkes, C M; Morgan, S E; Watson, A T; Held, T; Koch, H; Lewandowski, B; Pelizaeus, M; Peters, K; Schroeder, T; Steinke, M; Boyd, J T; Burke, J P; Cottingham, W N; Walker, D; Cuhadar-Donszelmann, T; Fulsom, B G; Hearty, C; Knecht, N S; Mattison, T S; McKenna, J A; Khan, A; Kyberd, P; Saleem, M; Sherwood, D J; Teodorescu, L; Blinov, V E; Bukin, A D; Druzhinin, V P; Golubev, V B; Onuchin, A P; Serednyakov, S I; Skovpen, Yu I; Solodov, E P; Todyshev, K Yu; Best, D S; Bondioli, M; Bruinsma, M; Chao, M; Curry, S; Eschrich, I; Kirkby, D; Lankford, A J; Lund, P; Mandelkern, M; Mommsen, R K; Roethel, W; Stoker, D P; Abachi, S; Buchanan, C; Foulkes, S D; Gary, J W; Long, O; Shen, B C; Wang, K; Zhang, L; Hadavand, H K; Hill, E J; Paar, H P; Rahatlou, S; Sharma, V; Berryhill, J W; Campagnari, C; Cunha, A; Dahmes, B; Hong, T M; Kovalskyi, D; Richman, J D; Beck, T W; Eisner, A M; Flacco, C J; Heusch, C A; Kroseberg, J; Lockman, W S; Nesom, G; Schalk, T; Schumm, B A; Seiden, A; Spradlin, P; Williams, D C; Wilson, M G; Albert, J; Chen, E; Dvoretskii, A; Fang, F; Hitlin, D G; Narsky, I; Piatenko, T; Porter, F C; Ryd, A; Samuel, A; Mancinelli, G; Meadows, B T; Mishra, K; Sokoloff, M D; Blanc, F; Bloom, P C; Chen, S; Ford, W T; Hirschauer, J F; Kreisel, A; Nagel, M; Nauenberg, U; Olivas, A; Ruddick, W O; Smith, J G; Ulmer, K A; Wagner, S R; Zhang, J; Chen, A; Eckhart, E A; Soffer, A; Toki, W H; Wilson, R J; Winklmeier, F; Zeng, Q; Altenburg, D D; Feltresi, E; Hauke, A; Jasper, H; Petzold, A; Spaan, B; Brandt, T; Klose, V; Lacker, H M; Mader, W F; Nogowski, R; Schubert, J; Schubert, K R; Schwierz, R; Sundermann, J E; Volk, A; Bernard, D; Bonneaud, G R; Grenier, P; Latour, E; Thiebaux, Ch; Verderi, M; Clark, P J; Gradl, W; Muheim, F; Playfer, S; Robertson, A I; Xie, Y; Andreotti, M; Bettoni, D; Bozzi, C; Calabrese, R; Cibinetto, G; Luppi, E; Negrini, M; Petrella, A; Piemontese, L; Prencipe, E; Anulli, F; Baldini-Ferroli, R; Calcaterra, A; de Sangro, R; Finocchiaro, G; Pacetti, S; Patteri, P; Peruzzi, I M; Piccolo, M; Rama, M; Zallo, A; Buzzo, A; Capra, R; Contri, R; Lo Vetere, M; Macri, M M; Monge, M R; Passaggio, S; Patrignani, C; Robutti, E; Santroni, A; Tosi, S; Brandenburg, G; Chaisanguanthum, K S; Morii, M; Wu, J; Dubitzky, R S; Marks, J; Schenk, S; Uwer, U; Bard, D J; Bhimji, W; Bowerman, D A; Dauncey, P D; Egede, U; Flack, R L; Nash, J A; Nikolich, M B; Panduro Vazquez, W; Behera, P K; Chai, X; Charles, M J; Mallik, U; Meyer, N T; Ziegler, V; Cochran, J; Crawley, H B; Dong, L; Eyges, V; Meyer, W T; Prell, S; Rosenberg, E I; Rubin, A E; Gritsan, A V; Denig, A G; Fritsch, M; Schott, G; Arnaud, N; Davier, M; Grosdidier, G; Höcker, A; Le Diberder, F; Lepeltier, V; Lutz, A M; Oyanguren, A; Pruvot, S; Rodier, S; Roudeau, P; Schune, M H; Stocchi, A; Wang, W F; Wormser, G; Cheng, C H; Lange, D J; Wright, D M; Chavez, C A; Forster, I J; Fry, J R; Gabathuler, E; Gamet, R; George, K A; Hutchcroft, D E; Payne, D J; Schofield, K C; Touramanis, C; Bevan, A J; Di Lodovico, F; Menges, W; Sacco, R; Cowan, G; Flaecher, H U; Hopkins, D A; Jackson, P S; McMahon, T R; Ricciardi, S; Salvatore, F; Wren, A C; Brown, D N; Davis, C L; Allison, J; Barlow, N R; Barlow, R J; Chia, Y M; Edgar, C L; Lafferty, G D; Naisbit, M T; Williams, J C; Yi, J I; Chen, C; Hulsbergen, W D; Jawahery, A; Lae, C K; Roberts, D A; Simi, G; Blaylock, G; Dallapiccola, C; Hertzbach, S S; Li, X; Moore, T B; Saremi, S; Staengle, H; Cowan, R; Sciolla, G; Sekula, S J; Spitznagel, M; Taylor, F; Yamamoto, R K; Kim, H; McLachlin, S E; Patel, P M; Robertson, S H; Lazzaro, A; Lombardo, V; Palombo, F; Bauer, J M; Cremaldi, L; Eschenburg, V; Godang, R; Kroeger, R; Sanders, D A; Summers, D J; Zhao, H W; Brunet, S; Côté, D; Simard, M; Taras, P; Viaud, F B; Nicholson, H; Cavallo, N; De Nardo, G; Fabozzi, F; Gatto, C; Lista, L; Monorchio, D; Paolucci, P; Piccolo, D; Sciacca, C; Baak, M; Raven, G; Snoek, H L; Jessop, C P; Losecco, J M; Allmendinger, T; Benelli, G; Gan, K K; Honscheid, K; Hufnagel, D; Jackson, P D; Kagan, H; Kass, R; Rahimi, A M; Ter-Antonyan, R; Wong, Q K; Blount, N L; Brau, J; Frey, R; Igonkina, O; Lu, M; Rahmat, R; Sinev, N B; Strom, D; Strube, J; Torrence, E; Gaz, A; Margoni, M; Morandin, M; Pompili, A; Posocco, M; Rotondo, M; Simonetto, F; Stroili, R; Voci, C; Benayoun, M; Chauveau, J; Briand, H; David, P; Del Buono, L; de la Vaissière, Ch; Hamon, O; Hartfiel, B L; John, M J J; Leruste, Ph; Malclès, J; Ocariz, J; Roos, L; Therin, G; Gladney, L; Panetta, J; Biasini, M; Covarelli, R; Angelini, C; Batignani, G; Bettarini, S; Bucci, F; Calderini, G; Carpinelli, M; Cenci, R; Forti, F; Giorgi, M A; Lusiani, A; Marchiori, G; Mazur, M A; Morganti, M; Neri, N; Paoloni, E; Rizzo, G; Walsh, J J; Haire, M; Judd, D; Wagoner, D E; Biesiada, J; Danielson, N; Elmer, P; Lau, Y P; Lu, C; Olsen, J; Smith, A J S; Telnov, A V; Bellini, F; Cavoto, G; D'Orazio, A; del Re, D; Di Marco, E; Faccini, R; Ferrarotto, F; Ferroni, F; Gaspero, M; Li Gioi, L; Mazzoni, M A; Morganti, S; Piredda, G; Polci, F; Safai Tehrani, F; Voena, C; Ebert, M; Schröder, H; Waldi, R; Adye, T; De Groot, N; Franek, B; Olaiya, E O; Wilson, F F; Aleksan, R; Emery, S; Gaidot, A; Ganzhur, S F; Hamel de Monchenault, G; Kozanecki, W; Legendre, M; Vasseur, G; Yèche, Ch; Zito, M; Chen, X R; Liu, H; Park, W; Purohit, M V; Wilson, J R; Allen, M T; Aston, D; Bartoldus, R; Bechtle, P; Berger, N; Claus, R; Coleman, J P; Convery, M R; Cristinziani, M; Dingfelder, J C; Dorfan, J; Dubois-Felsmann, G P; Dujmic, D; Dunwoodie, W; Field, R C; Glanzman, T; Gowdy, S J; Graham, M T; Halyo, V; Hast, C; Hryn'ova, T; Innes, W R; Kelsey, M H; Kim, P; Leith, D W G S; Li, S; Luitz, S; Luth, V; Lynch, H L; MacFarlane, D B; Marsiske, H; Messner, R; Muller, D R; O'Grady, C P; Ozcan, V E; Perazzo, A; Perl, M; Pulliam, T; Ratcliff, B N; Roodman, A; Salnikov, A A; Schindler, R H; Schwiening, J; Snyder, A; Stelzer, J; Su, D; Sullivan, M K; Suzuki, K; Swain, S K; Thompson, J M; Va'vra, J; van Bakel, N; Weaver, M; Weinstein, A J R; Wisniewski, W J; Wittgen, M; Wright, D H; Yarritu, A K; Yi, K; Young, C C; Burchat, P R; Edwards, A J; Majewski, S A; Petersen, B A; Roat, C; Wilden, L; Ahmed, S; Alam, M S; Bula, R; Ernst, J A; Jain, V; Pan, B; Saeed, M A; Wappler, F R; Zain, S B; Bugg, W; Krishnamurthy, M; Spanier, S M; Eckmann, R; Ritchie, J L; Satpathy, A; Schilling, C J; Schwitters, R F; Izen, J M; Lou, X C; Ye, S; Bianchi, F; Gallo, F; Gamba, D; Bomben, M; Bosisio, L; Cartaro, C; Cossutti, F; Della Ricca, G; Dittongo, S; Lanceri, L; Vitale, L; Azzolini, V; Martinez-Vidal, F; Banerjee, Sw; Bhuyan, B; Brown, C M; Fortin, D; Hamano, K; Kowalewski, R; Nugent, I M; Roney, J M; Sobie, R J; Back, J J; Harrison, P F; Latham, T E; Mohanty, G B; Pappagallo, M; Band, H R; Chen, X; Cheng, B; Dasu, S; Datta, M; Flood, K T; Hollar, J J; Kutter, P E; Mellado, B; Mihalyi, A; Pan, Y; Pierini, M; Prepost, R; Wu, S L; Yu, Z; Neal, H

    2006-11-24

    We report a measurement of the B-->pi l nu branching fraction based on 211 fb(-1) of data collected with the BABAR detector. We use samples of B0 and B+ mesons tagged by a second B meson reconstructed in a semileptonic or hadronic decay and combine the results assuming isospin symmetry to obtain B(B(0)-->pi- l+ nu) = (1.33+/-0.17stat+/-0.11syst) x 10(-4). We determine the magnitude of the Cabibbo-Kobayashi-Maskawa matrix element absolute value V(ub) by combining the partial branching fractions measured in ranges of the momentum transfer squared and theoretical calculations of the form factor. Using a recent lattice QCD calculation, we find absolute value V(ub) = (4.5+/-0.5stat+/-0.3syst(+0.7) -0.5FF x 10(-3), where the last error is due to the normalization of the form factor.

  10. Generalized approach for using unbiased symmetric metrics with negative values: normalized mean bias factor and normalized mean absolute error factor

    SciTech Connect

    Gustafson, William I.; Yu, Shaocai

    2012-10-23

    Unbiased symmetric metrics provide a useful measure to quickly compare two datasets, with similar interpretations for both under and overestimations. Two examples include the normalized mean bias factor and normalized mean absolute error factor. However, the original formulations of these metrics are only valid for datasets with positive means. This paper presents a methodology to use and interpret the metrics with datasets that have negative means. The updated formulations give identical results compared to the original formulations for the case of positive means, so researchers are encouraged to use the updated formulations going forward without introducing ambiguity.

  11. Absolute reliability of hamstring to quadriceps strength imbalance ratios calculated using peak torque, joint angle-specific torque and joint ROM-specific torque values.

    PubMed

    Ayala, F; De Ste Croix, M; Sainz de Baranda, P; Santonja, F

    2012-11-01

    The main purpose of this study was to determine the absolute reliability of conventional (H/Q(CONV)) and functional (H/Q(FUNC)) hamstring to quadriceps strength imbalance ratios calculated using peak torque values, 3 different joint angle-specific torque values (10°, 20° and 30° of knee flexion) and 4 different joint ROM-specific average torque values (0-10°, 11-20°, 21-30° and 0-30° of knee flexion) adopting a prone position in recreational athletes. A total of 50 recreational athletes completed the study. H/Q(CONV) and H/Q(FUNC) ratios were recorded at 3 different angular velocities (60, 180 and 240°/s) on 3 different occasions with a 72-96 h rest interval between consecutive testing sessions. Absolute reliability was examined through typical percentage error (CVTE), percentage change in the mean (CM) and intraclass correlations (ICC) as well as their respective confidence limits. H/Q(CONV) and H/Q(FUNC) ratios calculated using peak torque values showed moderate reliability values, with CM scores lower than 2.5%, CV(TE) values ranging from 16 to 20% and ICC values ranging from 0.3 to 0.7. However, poor absolute reliability scores were shown for H/Q(CONV) and H/Q(FUNC) ratios calculated using joint angle-specific torque values and joint ROM-specific average torque values, especially for H/Q(FUNC) ratios (CM: 1-23%; CV(TE): 22-94%; ICC: 0.1-0.7). Therefore, the present study suggests that the CV(TE) values reported for H/Q(CONV) and H/Q(FUNC) (≈18%) calculated using peak torque values may be sensitive enough to detect large changes usually observed after rehabilitation programmes but not acceptable to examine the effect of preventitive training programmes in healthy individuals. The clinical reliability of hamstring to quadriceps strength ratios calculated using joint angle-specific torque values and joint ROM-specific average torque values are questioned and should be re-evaluated in future research studies.

  12. Clinical value and severity of myocardial perfusion defects in asymptomatic diabetic patients with negative or weakly positive exercise treadmill test

    PubMed Central

    Zakavi, Seyed Rasoul; Taherpour, Mehdi; Moossavi, Zohreh; Sadeghi, Ramin; Kakhki, Vahidreza Dabbagh; Rokni, Haleh

    2013-01-01

    Objective: Although coronary artery disease (CAD) is the leading cause of death in type 2 diabetic patients, it is frequently asymptomatic. Myocardial perfusion imaging (MPI) is reported to show ischemia in a significant number of asymptomatic diabetic patients. We studied the prevalence and severity of myocardial perfusion defects in asymptomatic diabetic patients and its clinical impact. Methods and patients: One hundred thirty consecutive asymptomatic patients, aged 35-65 years with type 2 diabetes mellitus and with no history of CAD and no cardiac symptoms were recruited in the study. Echocardiography, electrocardiography (ECG), routine laboratory tests and exercise treadmill test (ETT) were performed and patients with weakly positive or negative ETT underwent Dipyridamole MPI. Patients with positive ETT were referred to coronary angiography. Patients were followed for at least 17 months (mean 21.7 months) and any cardiac event was recorded. Results: We studied 81 female and 49 male patients with mean age of 51.8 years. Negative, weakly positive and positive ETT result was noted in 74.3%, 15% and 10.7% respectively. 75% of patients with positive ETT had coronary artery disease in angiography. Gated myocardial perfusion SPECT was done in 106 patients. MPI showed reversible defect in 26.9% of the patients with a mean summed stress score of 3.3±1.8. Follow up completed in 112 patients and only one patient with abnormal MPI underwent coronary angiography followed by PTCA. No cardiac death, MI, UA or hospital admission occurred among our patients during follow up (17-26 months). Mean stress end diastolic volume (EDV) was significantly higher in patients with reversible defect compared to patients without reversible defect based on MPI findings (62.0±31.6 Vs 48.5±18.4 ml, P=0.04). Blood glucose and HbA1c were significantly higher in patients with ischemia compared to patients without ischemia (P<0.05). Meanwhile the ratio of TG to HDL was 6.06±3.2 in ischemic

  13. WE-G-18C-02: Estimation of Optimal B-Value Set for Obtaining Apparent Diffusion Coefficient Free From Perfusion in Non-Small Cell Lung Cancer

    SciTech Connect

    Karki, K; Hugo, G; Ford, J; Saraiya, S; Weiss, E; Olsen, K; Groves, R

    2014-06-15

    Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADCIVIM) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm and 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADCIVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADCIVIM, perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADCIVIM(p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADCIVIM, respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADCIVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets

  14. Influence of absolute argon and oxygen flow values at a constant ratio on the growth of Zn/ZnO nanostructures obtained by DC reactive magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Masłyk, M.; Borysiewicz, M. A.; Wzorek, M.; Wojciechowski, T.; Kwoka, M.; Kamińska, E.

    2016-12-01

    In the present work we analyze the growth mechanism of Zn/ZnO nanostructured thin films obtained by DC reactive magnetron sputtering with variable absolute gas flow values. Zn target was sputtered at 80 W DC power with variable absolute Ar:O2 flow values at a set ratio, in sccm: 3:0.3, 6:0.6, 8:0.8, 10:1, 15:1.5, 20:2 and 30:3. We obtained unique Zn/ZnO nanoflowers with morphology and properties changing as a function of gas flow values from dendritic/nanopetal structures for low flow to dense porous films for high flow. Zn core/ZnO shell composition results from surface oxidation of Zn crystallites to 4 nm thick ZnO after exposure to atmospheric air that causes an increase in resistivity especially for denser, more porous films. Taking into account that the plasma properties measures using the Langmuir probe and optical emission spectroscopy remain constant as a function of gas flow values, we put forward that the structural evolution of films is influenced by oxygen incorporating into the film surface acting as an inhibitor - incorporating into the films and decreasing crystallite sizes and amorphizing the film structure.

  15. Blood perfusion values of laser speckle contrast imaging and laser Doppler flowmetry: is a direct comparison possible?

    PubMed

    Binzoni, Tiziano; Humeau-Heurtier, Anne; Abraham, Pierre; Mahe, Guillaume

    2013-05-01

    Laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) allow the monitoring of microvascular blood perfusion. The relationship between the measurements obtained by these two techniques remains unclear. In the present contribution, we demonstrate, experimentally and theoretically, that skin blood flow measurements obtained by LDF and LSCI techniques cannot be compared directly even after "classical" normalization procedure. This technical problem is generated by the nonlinear relationship existing between LDF and LSCI flow data. The experiments have been performed on five healthy voluntary subjects (forearm) by using repeated ischemia/reperfusion cycles to induce the necessary skin blood flow changes. LDF and LSCI data were simultaneously acquired on the same region of interest. Considering the importance of this problem from the clinical point of view, it is concluded that the definition of new corrected algorithms for LSCI is probably a mandatory step that must be taken into account if LDF and LSCI blood flow have to be compared.

  16. [The influence of mode and intensity of homogenization on the absolute value and stability of oxygen consumption of guinea pig liver homogenates (author's transl)].

    PubMed

    Schmidt, H J; Schaum, U; Pichotka, J P

    1977-01-01

    The influence of five different methods of homogenisation (1. The method according to Potter and Elvehjem, 2. A modification of this method called Potter S, 3. The method of Dounce, 4. Homogenisation by hypersonic waves and 5. Coarce-grained homogenisation with the "Mikrofleischwolf") on the absolute value and stability of oxygen uptake of guinea pig liver homogenates has been investigated in simultaneous measurements. All homogenates showed a characteristic fall of oxygen uptake during measuring time (3 hours). The modified method according to Potter and Elvehjem called Potter S showed reproducible results without any influence by homogenisation intensity.

  17. The value of resting-state functional MRI in subacute ischemic stroke: comparison with dynamic susceptibility contrast-enhanced perfusion MRI.

    PubMed

    Ni, Ling; Li, Jingwei; Li, Weiping; Zhou, Fei; Wang, Fangfang; Schwarz, Christopher G; Liu, Renyuan; Zhao, Hui; Wu, Wenbo; Zhang, Xin; Li, Ming; Yu, Haiping; Zhu, Bin; Villringer, Arno; Zang, Yufeng; Zhang, Bing; Lv, Yating; Xu, Yun

    2017-01-31

    To evaluate the potential clinical value of the time-shift analysis (TSA) approach for resting-state fMRI (rs-fMRI) blood oxygenation level-dependent (BOLD) data in detecting hypoperfusion of subacute stroke patients through comparison with dynamic susceptibility contrast perfusion weighted imaging (DSC-PWI). Forty patients with subacute stroke (3-14 days after neurological symptom onset) underwent MRI examination. Cohort A: 31 patients had MRA, DSC-PWI and BOLD data. Cohort B: 9 patients had BOLD and MRA data. The time delay between the BOLD time course in each voxel and the mean signal of global and contralateral hemisphere was calculated using TSA. Time to peak (TTP) was employed to detect hypoperfusion. Among cohort A, 14 patients who had intracranial large-vessel occlusion/stenosis with sparse collaterals showed hypoperfusion by both of the two approaches, one with abundant collaterals showed neither TTP nor TSA time delay. The remaining 16 patients without obvious MRA lesions showed neither TTP nor TSA time delay. Among cohort B, eight patients showed time delay areas. The TSA approach was a promising alternative to DSC-PWI for detecting hypoperfusion in subacute stroke patients who had obvious MRA lesions with sparse collaterals, those with abundant collaterals would keep intact local perfusion.

  18. The value of resting-state functional MRI in subacute ischemic stroke: comparison with dynamic susceptibility contrast-enhanced perfusion MRI

    PubMed Central

    Ni, Ling; Li, Jingwei; Li, Weiping; Zhou, Fei; Wang, Fangfang; Schwarz, Christopher G.; Liu, Renyuan; Zhao, Hui; Wu, Wenbo; Zhang, Xin; Li, Ming; Yu, Haiping; Zhu, Bin; Villringer, Arno; Zang, Yufeng; Zhang, Bing; Lv, Yating; Xu, Yun

    2017-01-01

    To evaluate the potential clinical value of the time-shift analysis (TSA) approach for resting-state fMRI (rs-fMRI) blood oxygenation level-dependent (BOLD) data in detecting hypoperfusion of subacute stroke patients through comparison with dynamic susceptibility contrast perfusion weighted imaging (DSC-PWI). Forty patients with subacute stroke (3–14 days after neurological symptom onset) underwent MRI examination. Cohort A: 31 patients had MRA, DSC-PWI and BOLD data. Cohort B: 9 patients had BOLD and MRA data. The time delay between the BOLD time course in each voxel and the mean signal of global and contralateral hemisphere was calculated using TSA. Time to peak (TTP) was employed to detect hypoperfusion. Among cohort A, 14 patients who had intracranial large-vessel occlusion/stenosis with sparse collaterals showed hypoperfusion by both of the two approaches, one with abundant collaterals showed neither TTP nor TSA time delay. The remaining 16 patients without obvious MRA lesions showed neither TTP nor TSA time delay. Among cohort B, eight patients showed time delay areas. The TSA approach was a promising alternative to DSC-PWI for detecting hypoperfusion in subacute stroke patients who had obvious MRA lesions with sparse collaterals, those with abundant collaterals would keep intact local perfusion. PMID:28139701

  19. Complementary Prognostic Values of Stress Myocardial Perfusion and Late Gadolinium Enhancement Imaging by Cardiac Magnetic Resonance in Patients with Known or Suspected Coronary Artery Disease

    PubMed Central

    Steel, Kevin; Broderick, Ryan; Gandla, Vijay; Larose, Eric; Resnic, Frederick; Jerosch-Herold, Michael; Brown, Kenneth A.; Kwong, Raymond Y.

    2009-01-01

    BACKGROUND Recent studies have demonstrated the significant prognostic value of stress CMR myocardial perfusion imaging (CMRMPI). Apart from characterizing reversible perfusion defect (RevPD) from flow-limiting coronary stenosis, CMR late enhancement imaging (LGE) is currently the most sensitive method in detecting subendocardial infarction (MI). We therefore tested the hypothesis that, characterization of these 2 processes from coronary artery disease (CAD) by CMR can provide complementary prognostic values. Methods and Results We performed CMRMPI followed by LGE imaging on 254 patients referred with symptoms of myocardial ischemia. At a median follow up of 17 months, 49 cardiac events (MACE) occurred including 12 cardiac deaths, 16 acute myocardial infarction (MI), and 21 cardiac hospitalizations. RevPD and LGE both maintained a > 3-fold association with cardiac death or acute MI (Death/MI) when adjusted to each other and to the effects of patient age and gender (adjusted HR 3.31, P=0.02 and 3.43, P=0.01, respectively). In patients without a history of MI who had negative RevPD, LGE presence was associated with >11-fold hazards increase to Death/MI. Patients with neither RevPD nor LGE had a 98.1% negative annual event rate for Death/MI. For association with MACE, RevPD was the strongest multivariable variable in the best overall model (HR 10.92, P<0.0001). Conclusions CMR imaging provides robust risk-stratification of patients who presents with symptoms of ischemia. Characterization of RevPD and LGE by CMR provides strong and complementary prognostic implication towards cardiac death or acute MI. PMID:19770399

  20. Prognostic value of dobutamine stress myocardial perfusion echocardiography in patients with known or suspected coronary artery disease and normal left ventricular function

    PubMed Central

    Mattoso, Angele A. A.; Tsutsui, Jeane M.; Kowatsch, Ingrid; Cruz, Vitória Y. L.; Sbano, João C. N.; Ribeiro, Henrique B.; Kalil Filho, Roberto; Porter, Thomas R.; Mathias, Wilson

    2017-01-01

    Objective We sought to determine the prognostic value of qualitative and quantitative analysis obtained by real-time myocardial perfusion echocardiography (RTMPE) in patients with known or suspected coronary artery disease (CAD). Background Quantification of myocardial blood flow reserve (MBFR) in patients with CAD using RTMPE has been demonstrated to further improve accuracy over the analysis of wall motion (WM) and qualitative analysis of myocardial perfusion (QMP). Methods From March 2003 to December 2008, we prospectively studied 168 patients with normal left ventricular function (LVF) who underwent dobutamine stress RTMPE. The replenishment velocity reserve (β) and MBFR were derived from RTMPE. Acute coronary events were: cardiac death, myocardial infarction and unstable angina with need for urgent coronary revascularization. Results During a median follow-up of 34 months (5 days to 6.9 years), 17 acute coronary events occurred. Abnormal β reserve in ≥2 coronary territories was the only independent predictor of events hazard ratio (HR) = 21, 95% CI = 4.5–99; p<0.001). Both, abnormal β reserve and MBFR added significant incremental value in predicting events over qualitative analysis of WM and MP (χ2 = 6.6 and χ2 = 24.6, respectively; p = 0.001 and χ2 = 6.6 and χ2 = 15.5, respectively; p = 0.012, respectively). When coronary angiographic data was added to the multivariate analysis model, β reserve remained the only predictor of events with HR of 21.0 (95% CI = 4.5–99); p<0.001. Conclusion Quantitative dobutamine stress RTMPE provides incremental prognostic information over clinical variables, qualitative analysis of WM and MP, and coronary angiography in predicting acute coronary events. PMID:28234978

  1. Renal perfusion scintiscan

    MedlinePlus

    Renal perfusion scintigraphy; Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion ... supply the kidneys. This is a condition called renal artery stenosis. Significant renal artery stenosis may be ...

  2. Comparison of high energy gamma rays from absolute value of b greater than 30 deg with the galactic neutral hydrogen distribution

    NASA Technical Reports Server (NTRS)

    Ozel, M. E.; Ogelman, H.; Tumer, T.; Fichtel, C. E.; Hartman, R. C.; Kniffen, D. A.; Thompson, F. J.

    1978-01-01

    High-energy gamma-ray (energy above 35 MeV) data from the SAS 2 satellite have been used to compare the intensity distribution of gamma rays with that of neutral hydrogen (H I) density along the line of sight, at high galactic latitudes (absolute values greater than 30 deg). A model has been constructed for the case where the observed gamma-ray intensity has been assumed to be the sum of a galactic component proportional to the H I distribution plus an isotropic extragalactic emission. A chi-squared test of the model parameters indicates that about 30% of the total high-latitude emission may originate within the Galaxy.

  3. Absolute Zero

    NASA Astrophysics Data System (ADS)

    Donnelly, Russell J.; Sheibley, D.; Belloni, M.; Stamper-Kurn, D.; Vinen, W. F.

    2006-12-01

    Absolute Zero is a two hour PBS special attempting to bring to the general public some of the advances made in 400 years of thermodynamics. It is based on the book “Absolute Zero and the Conquest of Cold” by Tom Shachtman. Absolute Zero will call long-overdue attention to the remarkable strides that have been made in low-temperature physics, a field that has produced 27 Nobel Prizes. It will explore the ongoing interplay between science and technology through historical examples including refrigerators, ice machines, frozen foods, liquid oxygen and nitrogen as well as much colder fluids such as liquid hydrogen and liquid helium. A website has been established to promote the series: www.absolutezerocampaign.org. It contains information on the series, aimed primarily at students at the middle school level. There is a wealth of material here and we hope interested teachers will draw their student’s attention to this website and its substantial contents, which have been carefully vetted for accuracy.

  4. The determination of presynaptic KA values of methacholine and pilocarpine and of a presynaptic receptor reserve in the rat perfused heart.

    PubMed Central

    Fuchs, P.; Fuder, H.

    1985-01-01

    Rat isolated perfused hearts with the right sympathetic nerves attached were loaded with [3H]-noradrenaline. The nerves were stimulated with up to 11 trains of 10 pulses at 0.1 Hz. The evoked increases of [3H]-noradrenaline overflow into the perfusate were measured in the presence of cocaine, corticosterone and propranolol. Activation of presynaptic muscarinic receptors by methacholine or pilocarpine inhibited the evoked transmitter release in a reversible and concentration-dependent manner. Preperfusion with phenoxybenzamine (5 microM) for 15 min (followed by a washout of 35 min) changed neither resting nor evoked overflow of [3H]-noradrenaline. The concentration-response curve of methacholine was shifted to the right after exposure of the hearts to phenoxybenzamine (1 microM) without depression of the maximum effect. Pretreatment with phenoxybenzamine (5 microM) reduced the maximum inhibition of release by about 50%. Analysis of the data gave a dissociation constant for the agonist-receptor complex (KA) of 4.0 microM and a receptor reserve of roughly 70%. Half-maximal inhibition of [3H]-noradrenaline release occurred when about 2% of the total receptor population was occupied. Comparison of the concentration-response data for methacholine and pilocarpine revealed a relative efficacy (methacholine/pilocarpine) of 16, a KA of 10 microM for pilocarpine and no receptor reserve for this agonist. The results show that KA values for methacholine and pilocarpine obtained at presynaptic receptors are similar to those obtained at postsynaptic muscarinic receptors. This is in agreement with the idea that muscarinic receptors located on postganglionic adrenergic nerves are not different from those located on effector sites of non-neuronal tissue. PMID:2983804

  5. Estimation of optimal b-value sets for obtaining apparent diffusion coefficient free from perfusion in non-small cell lung cancer.

    PubMed

    Karki, Kishor; Hugo, Geoffrey D; Ford, John C; Olsen, Kathryn M; Saraiya, Siddharth; Groves, Robert; Weiss, Elisabeth

    2015-10-21

    The purpose of this study was to determine optimal sets of b-values in diffusion-weighted MRI (DW-MRI) for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADCIVIM) in non-small cell lung cancer. Ten subjects had 40 DW-MRI scans before and during radiotherapy in a 1.5 T MRI scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR ≈ 4500 ms, TE  =  74 ms, eight b-values of 0-1000 μs μm(-2), pixel size  =  1.98 × 1.98 mm(2), slice thickness  =  6 mm, interslice gap  =  1.2 mm, 7 axial slices and total acquisition time ≈6 min. One or more DW-MRI scans together covered the whole tumour volume. Monoexponential model ADC values using various b-value sets were compared to reference-standard ADCIVIM values using all eight b-values. Intra-scan coefficient of variation (CV) of active tumour volumes was computed to compare the relative noise in ADC maps. ADC values for one pre-treatment DW-MRI scan of each of the 10 subjects were computed using b-value pairs from DW-MRI images synthesized for b-values of 0-2000 μs μm(-2) from the estimated IVIM parametric maps and corrupted by various Rician noise levels. The square root of mean of squared error percentage (RMSE) of the ADC value relative to the corresponding ADCIVIM for the tumour volume of the scan was computed. Monoexponential ADC values for the b-value sets of 250 and 1000; 250, 500 and 1000; 250, 650 and 1000; 250, 800 and 1000; and 250-1000 μs μm(-2) were not significantly different from ADCIVIM values (p > 0.05, paired t-test). Mean error in ADC values for these sets relative to ADCIVIM were within 3.5%. Intra-scan CVs for these sets were comparable to that for ADCIVIM. The monoexponential ADC values for other sets-0-1000; 50-1000; 100-1000; 500-1000; and 250 and 800 μs μm(-2) were significantly different from the ADCIVIM values. From Rician noise

  6. Estimation of optimal b-value sets for obtaining apparent diffusion coefficient free from perfusion in non-small cell lung cancer

    NASA Astrophysics Data System (ADS)

    Karki, Kishor; Hugo, Geoffrey D.; Ford, John C.; Olsen, Kathryn M.; Saraiya, Siddharth; Groves, Robert; Weiss, Elisabeth

    2015-10-01

    The purpose of this study was to determine optimal sets of b-values in diffusion-weighted MRI (DW-MRI) for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADCIVIM) in non-small cell lung cancer. Ten subjects had 40 DW-MRI scans before and during radiotherapy in a 1.5 T MRI scanner. Respiratory triggering was applied to the echo-planar DW-MRI with \\text{TR}≈ 4500 ms, TE  =  74 ms, eight b-values of 0-1000 μs μm-2, pixel size  =  1.98× 1.98 mm2, slice thickness  =  6 mm, interslice gap  =  1.2 mm, 7 axial slices and total acquisition time ≈6 min. One or more DW-MRI scans together covered the whole tumour volume. Monoexponential model ADC values using various b-value sets were compared to reference-standard ADCIVIM values using all eight b-values. Intra-scan coefficient of variation (CV) of active tumour volumes was computed to compare the relative noise in ADC maps. ADC values for one pre-treatment DW-MRI scan of each of the 10 subjects were computed using b-value pairs from DW-MRI images synthesized for b-values of 0-2000 μs μm-2 from the estimated IVIM parametric maps and corrupted by various Rician noise levels. The square root of mean of squared error percentage (RMSE) of the ADC value relative to the corresponding ADCIVIM for the tumour volume of the scan was computed. Monoexponential ADC values for the b-value sets of 250 and 1000; 250, 500 and 1000; 250, 650 and 1000; 250, 800 and 1000; and 250-1000 μs μm-2 were not significantly different from ADCIVIM values (p>0.05 , paired t-test). Mean error in ADC values for these sets relative to ADCIVIM were within 3.5%. Intra-scan CVs for these sets were comparable to that for ADCIVIM. The monoexponential ADC values for other sets—0-1000 50-1000 100-1000 500-1000 and 250 and 800 μs μm-2 were significantly different from the ADCIVIM values. From Rician noise simulation

  7. Absolute Summ

    NASA Astrophysics Data System (ADS)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  8. Prognostic Value of Combined CT Angiography and Myocardial Perfusion Imaging versus Invasive Coronary Angiography and Nuclear Stress Perfusion Imaging in the Prediction of Major Adverse Cardiovascular Events: The CORE320 Multicenter Study.

    PubMed

    Chen, Marcus Y; Rochitte, Carlos E; Arbab-Zadeh, Armin; Dewey, Marc; George, Richard T; Miller, Julie M; Niinuma, Hiroyuki; Yoshioka, Kunihiro; Kitagawa, Kakuya; Sakuma, Hajime; Laham, Roger; Vavere, Andrea L; Cerci, Rodrigo J; Mehra, Vishal C; Nomura, Cesar; Kofoed, Klaus F; Jinzaki, Masahiro; Kuribayashi, Sachio; Scholte, Arthur J; Laule, Michael; Tan, Swee Yaw; Hoe, John; Paul, Narinder; Rybicki, Frank J; Brinker, Jeffrey A; Arai, Andrew E; Matheson, Matthew B; Cox, Christopher; Clouse, Melvin E; Di Carli, Marcelo F; Lima, João A C

    2017-03-14

    Purpose To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial perfusion imaging. Materials and Methods This study was approved by all institutional review boards, and written informed consent was obtained. Between November 2009 and July 2011, 381 participants clinically referred for ICA and aged 45-85 years were enrolled in the Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) prospective multicenter diagnostic study. All images were analyzed in blinded independent core laboratories, and a panel of physicians adjudicated all adverse events. MACE was defined as revascularization (>30 days after index ICA), myocardial infarction, or cardiac death; hospitalization for chest pain or congestive heart failure; or arrhythmia. Late MACE was defined similarly, except for patients who underwent revascularization within the first 182 days after ICA, who were excluded. Comparisons of 2-year survival (time to MACE) used standard Kaplan-Meier curves and restricted mean survival times bootstrapped with 2000 replicates. Results An MACE (49 revascularizations, five myocardial infarctions, one cardiac death, nine hospitalizations for chest pain or congestive heart failure, and one arrhythmia) occurred in 51 of 379 patients (13.5%). The 2-year MACE-free rates for combined CT angiography and CT perfusion findings were 94% negative for coronary artery disease (CAD) versus 82% positive for CAD and were similar to combined ICA and single photon emission CT findings (93% negative for CAD vs 77% positive for CAD, P < .001 for both). Event-free rates for CT angiography and CT perfusion versus ICA and single photon emission CT for either positive or negative results were not

  9. Absolute Photometry

    NASA Astrophysics Data System (ADS)

    Hartig, George

    1990-12-01

    The absolute sensitivity of the FOS will be determined in SV by observing 2 stars at 3 epochs, first in 3 apertures (1.0", 0.5", and 0.3" circular) and then in 1 aperture (1.0" circular). In cycle 1, one star, BD+28D4211 will be observed in the 1.0" aperture to establish the stability of the sensitivity and flat field characteristics and improve the accuracy obtained in SV. This star will also be observed through the paired apertures since these are not calibrated in SV. The stars will be observed in most detector/grating combinations. The data will be averaged to form the inverse sensitivity functions required by RSDP.

  10. Value of Perfusion-Weighted MR Imaging in the Assessment of Early Cerebral Alterations in Neurologically Asymptomatic HIV-1-Positive and HCV-Positive Patients

    PubMed Central

    Bladowska, Joanna; Knysz, Brygida; Zimny, Anna; Małyszczak, Krzysztof; Kołtowska, Anna; Szewczyk, Paweł; Gąsiorowski, Jacek; Furdal, Michał; Sąsiadek, Marek J.

    2014-01-01

    Background and Purpose Asymptomatic central nervous system (CNS) involvement occurs in the early stage of the human immunodeficiency virus (HIV) infection. It has been documented that the hepatitis C virus (HCV) can replicate in the CNS. The aim of the study was to evaluate early disturbances in cerebral microcirculation using magnetic resonance (MR) perfusion-weighted imaging (PWI) in asymptomatic HIV-1-positive and HCV-positive patients, as well as to assess the correlation between PWI measurements and the clinical data. Materials and Methods Fifty-six patients: 17 HIV-1-positive non-treated, 18 HIV-1-positive treated with combination antiretroviral therapy (cART), 7 HIV-1/HCV-positive non-treated, 14 HCV-positive before antiviral therapy and 18 control subjects were enrolled in the study. PWI was performed with a 1.5T MR unit using dynamic susceptibility contrast (DSC) method. Cerebral blood volume (CBV) measurements relative to cerebellum (rCBV) were evaluated in the posterior cingulated region (PCG), basal ganglia (BG), temporoparietal (TPC) and frontal cortices (FC), as well as in white matter of frontoparietal areas. Correlations of rCBV values with immunologic data and liver histology activity index (HAI) were analyzed. Results Significantly lower rCBV values were found in the right TPC and left FC as well as in PCG in HIV-1-positive naïve (p = 0.009; p = 0.020; p = 0.012), HIV-1 cART treated (p = 0.007; p = 0.009; p = 0.033), HIV-1/HCV-positive (p = 0.007; p = 0.027; p = 0.045) and HCV-positive patients (p = 0.010; p = 0.005; p = 0.045) compared to controls. HIV-1-positive cART treated and HIV-1/HCV-positive patients demonstrated lower rCBV values in the right FC (p = 0.009; p = 0.032, respectively) and the left TPC (p = 0.036; p = 0.005, respectively), while HCV-positive subjects revealed lower rCBV values in the left TPC region (p = 0.003). We found significantly elevated rCBV values in

  11. Prognostic value of thallium-201 myocardial perfusion imaging in patients with unstable angina who respond to medical treatment

    SciTech Connect

    Brown, K.A. )

    1991-04-01

    Although the prognostic value of thallium-201 imaging is well established, its ability to risk stratify patients who present with unstable angina is unclear. Fifty-two consecutive patients admitted with unstable angina who responded to medical treatment and underwent stress thallium-201 imaging within 1 week of discharge were studied. Patients were followed up for 39 +/- 11 months. Cardiac events included cardiac death (n = 3), nonfatal myocardial infarction (n = 4) and admission for unstable angina or revascularization (n = 17). The ability of thallium-201 data (redistribution, fixed defects, normal) to predict cardiac events was compared with clinical data (age, gender, prior myocardial infarction, anginal syndrome, rest and stress electrocardiogram) and cardiac catheterization data using logistic regression. Thallium-201 redistribution was the only significant predictor of cardiac death or nonfatal myocardial infarction (p less than 0.05). The number of myocardial segments with thallium-201 redistribution (p less than 0.0005) and a history of prior myocardial infarction (p less than 0.05) were the only significant predictors of all cardiac events. Cardiac death or nonfatal myocardial infarction occurred more frequently in patients with thallium-201 redistribution (6 (26%) of 23) than in those without redistribution (1 (3%) of 29, p less than 0.05). Similarly, total cardiac events developed more frequently in patients with thallium-201 redistribution (p less than 0.001). Stress thallium-201 imaging has important prognostic value in patients admitted with unstable angina who respond to medical therapy and can identify subgroups at high versus low risk for future cardiac events.

  12. The predictive value of chronic kidney disease for assessing cardiovascular events under consideration of pretest probability for coronary artery disease in patients who underwent stress myocardial perfusion imaging.

    PubMed

    Furuhashi, Tatsuhiko; Moroi, Masao; Joki, Nobuhiko; Hase, Hiroki; Masai, Hirofumi; Kunimasa, Taeko; Fukuda, Hiroshi; Sugi, Kaoru

    2013-02-01

    Pretest probability of coronary artery disease (CAD) facilitates diagnosis and risk stratification of CAD. Stress myocardial perfusion imaging (MPI) and chronic kidney disease (CKD) are established major predictors of cardiovascular events. However, the role of CKD to assess pretest probability of CAD has been unclear. This study evaluates the role of CKD to assess the predictive value of cardiovascular events under consideration of pretest probability in patients who underwent stress MPI. Patients with no history of CAD underwent stress MPI (n = 310; male = 166; age = 70; CKD = 111; low/intermediate/high pretest probability = 17/194/99) and were followed for 24 months. Cardiovascular events included cardiac death and nonfatal acute coronary syndrome. Cardiovascular events occurred in 15 of the 310 patients (4.8 %), but not in those with low pretest probability which included 2 CKD patients. In patients with intermediate to high pretest probability (n = 293), multivariate Cox regression analysis identified only CKD [hazard ratio (HR) = 4.88; P = 0.022) and summed stress score of stress MPI (HR = 1.50; P < 0.001) as independent and significant predictors of cardiovascular events. Cardiovascular events were not observed in patients with low pretest probability. In patients with intermediate to high pretest probability, CKD and stress MPI are independent predictors of cardiovascular events considering the pretest probability of CAD in patients with no history of CAD. In assessing pretest probability of CAD, CKD might be an important factor for assessing future cardiovascular prognosis.

  13. Dynamic chest radiography with a flat-panel detector (FPD): ventilation-perfusion study

    NASA Astrophysics Data System (ADS)

    Tanaka, R.; Sanada, S.; Fujimura, M.; Yasui, M.; Tsuji, S.; Hayashi, N.; Okamoto, H.; Nanbu, Y.; Matsui, O.

    2011-03-01

    Pulmonary ventilation and blood flow are reflected in dynamic chest radiographs as changes in X-ray translucency, i.e., pixel values. This study was performed to investigate the feasibility of ventilation-perfusion (V/Q) study based on the changes in pixel value. Sequential chest radiographs of a patient with ventilation-perfusion mismatch were obtained during respiration using a dynamic flat-panel detector (FPD) system. The lung area was recognized and average pixel value was measured in each area, tracking and deforming the region of interest. Inter-frame differences were then calculated, and the absolute values were summed in each respiratory phase. The results were visualized as ventilation, blood flow, V/Q ratio distribution map and compared to distribution of radioactive counts on ventilation and perfusion scintigrams. In the results, abnormalities were appeared as a reduction of changes in pixel values, and a correlation was observed between the distribution of changes in pixel value and those of radioactivity counts (Ventilation; r=0.78, Perfusion; r=0.77). V/Q mismatch was also indicated as mismatch of changes in pixel value, and a correlation with V/Q calculated by radioactivity counts (r=0.78). These results indicated that the present method is potentially useful for V/Q study as an additional examination in conventional chest radiography.

  14. The influence of walking with an orthosis on bone mineral density by determination of the absolute values of the loads applied on the limb.

    PubMed

    Karimi, Mohammad Taghi

    2012-03-01

    Spinal cord injury is damage to the spinal cord that results in loss of mobility and sensation below the level of injury. Most patients use various types of orthoses to stand and walk. It has been claimed that walking and standing with orthosis reduces bone osteoporosis, improves joint range of motion and decreases muscle spasm. Unfortunately, there are discrepancies regarding the clinical effects of walking and standing on bone mineral density. The aim of this research was to find the absolute values of the loads transmitted by body and orthosis in walking with use of an orthosis. 5 normal subjects were recruited to stand and walk with a new design of reciprocal gait orthosis. The loads transmitted through the orthosis and anatomy was measured by use of strain gauge and motion analysis systems. It has been shown that the loads applied on the anatomy were significantly more than that transmitted through the orthosis. Moreover, the patterns of the forces and moments of the orthosis and body completely differed from each other. As the most part of the loads applied on the complex transmitted by anatomy in walking with an orthosis, walking with orthosis can influence bone mineral density.

  15. Ultrasound perfusion analysis combining bolus-tracking and burst-replenishment.

    PubMed

    Jirik, Radovan; Nylund, Kim; Gilja, Odd H; Mezl, Martin; Harabis, Vratislav; Kolar, Radim; Standara, Michal; Taxt, Torfinn

    2013-02-01

    A new signal model and processing method for quantitative ultrasound perfusion analysis is presented, called bolus-and-burst. The method has the potential to provide absolute values of blood flow, blood volume, and mean transit time. Furthermore, it provides an estimate of the local arterial input function which characterizes the arterial tree, allowing accurate estimation of the bolus arrival time. The method combines two approaches to ultrasound perfusion analysis: bolus-tracking and burst-replenishment. A pharmacokinetic model based on the concept of arterial input functions and tissue residue functions is used to model both the bolus and replenishment parts of the recording. The pharmacokinetic model is fitted to the data using blind deconvolution. A preliminary assessment of the new perfusion-analysis method is presented on clinical recordings.

  16. Comparative value of maximal treadmill testing, exercise thallium myocardial perfusion scintigraphy and exercise radionuclide ventriculography for distinguishing high- and low-risk patients soon after acute myocardial infarction

    SciTech Connect

    Hung, J.; Goris, M.L.; Nash, E.; Kraemer, H.C.; DeBusk, R.F.; Berger, W.E.; Lew, H.

    1984-05-01

    The prognostic value of symptom-limited treadmill exercise electrocardiography, exercise thallium myocardial perfusion scintigraphy and rest and exercise radionuclide ventriculography was compared in 117 men, aged 54 +/- 9 years, tested 3 weeks after a clinically uncomplicated acute myocardial infarction (MI). During a mean follow-up period of 11.6 months, 8 men experienced ''hard'' medical events (cardiac death, nonfatal ventricular fibrillation or recurrent MI) and 14 were hospitalized for unstable angina pectoris, congestive heart failure or coronary bypass surgery (total of 22 combined events). By multivariate analysis (Cox proportional hazards model), peak treadmill work load and the change in left ventricular ejection fraction (EF) during exercise were significant (p less than 0.01) predictors of hard medical events; these 2 risk factors and recurrent ischemic chest pain in the coronary care unit were also significantly predictive (p less than 0.001) for combined events. A peak treadmill work load of 4 METs or less or a decrease in EF of 5% or more below the value at rest during submaximal effort distinguished 22 high-risk patients (20% of the study population) from 89 low-risk patients. The rate of hard medical events within 12 months was 23% (5 of 22 patients), vs 2% (2 of 89 patients) in the high- and low-risk patient subsets, respectively (p less than 0.001). Thus, in patients who underwent evaluation 3 weeks after a clinically uncomplicated MI, exercise radionuclide ventriculography contributed independent prognostic information to that provided by symptom-limited treadmill testing and was superior to exercise thallium scintigraphy for this purpose.

  17. Impact of Gender on the Prognostic Value of Coronary Artery Calcium in Symptomatic Patients With Normal Single-Photon Emission Computed Tomography Myocardial Perfusion.

    PubMed

    Engbers, Elsemiek M; Timmer, Jorik R; Ottervanger, Jan Paul; Mouden, Mohamed; Knollema, Siert; Jager, Pieter L

    2016-12-01

    The coronary artery calcium (CAC) score provides independent prognostic value on top of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). We sought to determine whether the prognostic value of the CAC score in patients with normal SPECT MPI is gender specific. We studied 3,705 consecutive symptomatic patients without a history of coronary artery disease with normal SPECT MPI. All patients underwent concomitant CAC scoring, which was categorized as CAC score 0, 1 to 99, 100 to 399, 400 to 999, or ≥1,000. Major adverse cardiac events were defined as revascularization, nonfatal myocardial infarction, or all-cause mortality. The median CAC score was 9 in women (interquartile range 0 to 113) and 47 in men (interquartile range 1 to 307, p <0.001). The annual event rate was lower in women than in men (1.6% and 2.7%, respectively, p <0.001). When stratified by CAC score, annual event rates were similar (for women and men, respectively: CAC score 0, 0.6% and 0.5%, p = 0.95; CAC score 1 to 99, 0.9% and 1.2%, p = 0.45; CAC score 100 to 399, 2.7% and 3.8%, p = 0.23; CAC score 400 to 999, 3.8% and 5.3%, p = 0.34; CAC score ≥1,000, 8.4% and 8.7%, p = 0.99). The CAC score was an independent predictor of major adverse cardiac events in both genders (CAC score ≥1,000: hazard ratio for women 8.5, 95% confidence interval 4.0 to 18.1; hazard ratio for men 14.8, 95% confidence interval 5.3 to 41.1). In conclusion, risk for events is similar for both genders when stratified by CAC score, wherein a high CAC score carries a high risk for events despite normal SPECT MPI. Our findings do not reveal a gender-specific prognostic value of the CAC score.

  18. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    PubMed

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted.

  19. Augmented myocardial perfusion reserve after coronary angioplasty quantified by positron emission tomography with H2(15)O

    SciTech Connect

    Walsh, M.N.; Geltman, E.M.; Steele, R.L.; Kenzora, J.L.; Ludbrook, P.A.; Sobel, B.E.; Bergmann, S.R. )

    1990-01-01

    Effects of coronary angioplasty on myocardial flow reserve have been difficult to characterize noninvasively because conventional imaging techniques cannot quantitate blood flow in absolute terms. The effects of coronary angioplasty on myocardial perfusion and perfusion reserve were delineated with positron emission tomography and oxygen-15-labeled water (H2(15)O) in 13 patients before and after single vessel angioplasty. In 11 patients, angioplasty was successful (minimal cross-sectional area increased from 0.60 +/- 0.59 to 3.45 +/- 1.09 mm2, p less than 0.001). In these patients, regional H2(15)O radioactivity (the ratio of nutritional perfusion in regions distal to the stenosis compared with regions supplied by angiographically normal arteries) at rest before angioplasty was 55 +/- 22% of peak myocardial radioactivity and did not increase significantly afterward (70 +/- 16%, p = NS). However, after administration of intravenous dipyridamole, hyperemic perfusion in regions distal to a stenosis averaged only 39 +/- 18% of peak myocardial counts before angioplasty, but increased to 66 +/- 22% after angioplasty (p less than 0.02). Perfusion reserve in the two patients in whom angioplasty was angiographically unsuccessful showed no change. Quantitative estimates of perfusion in absolute rather than relative terms were obtained with positron emission tomographic data from seven of the patients with successful angioplasty. At rest, perfusion in regions distal to a stenosis was not different from the values in regions supplied by normal coronary arteries (1.54 +/- 0.54 compared with 1.46 +/- 0.38 ml/g per min, p = NS).

  20. Predictive values of diffusion-weighted imaging and perfusion-weighted imaging in evaluating the efficacy of transcatheter arterial chemoembolization for hepatocellular carcinoma

    PubMed Central

    Lin, Min; Tian, Man-Man; Zhang, Wei-Ping; Xu, Li; Jin, Ping

    2016-01-01

    This study explored the predictive values of diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) in evaluating the efficacy of transcatheter arterial chemoembolization (TACE) for patients with hepatocellular carcinoma (HCC). A total of 118 HCC patients treated with TACE were selected from April 2013 to November 2015. T1-weighted imaging (T1WI)/T2-weighted imaging (T2WI), DWI, and PWI were performed on all patients before and after TACE. Efficacy was evaluated according to modified Response Evaluation Criteria in Solid Tumors 1.1. Receiver operating characteristic curve was used to evaluate the diagnostic power of quantitative DWI and PWI parameters in evaluating the efficacy of TACE for HCC patients. Among the 118 HCC patients, there were 17 cases (14.4%) with complete response, 50 cases (42.4%) with partial response, 28 cases (23.7%) with stable disease, and 23 cases (19.5%) with progressive disease. There were 67 patients in the effective group (complete response + partial response) and 51 patients in the ineffective group (stable disease + progressive disease). Before TACE, there were significant differences in maximum tumor diameter (MTD), apparent diffusion coefficient (ADC), slow ADC (Dslow), fast ADC (Dfast), transfer constant of vessel at the maximum level (Ktrans), and rate constant of backflux (Kep) between the effective and ineffective groups (all P<0.05). After TACE, the effective group exhibited lower MTD, Dfast, and Kep and higher ADC and Dslow than the ineffective group (all P<0.05). Tumor regression rate negatively correlated with MTD, Ktrans, Kep, and Dfast but positively correlated with ADC and Dslow. Receiver operating characteristic curve analysis suggested that the area under the curve of ADC, Dslow, Dfast, Ktrans, and Kep were 0.869, 0.833, 0.812, 0.802, and 0.809, respectively. In conclusion, these results suggest that quantitative DWI and PWI parameters might be useful in evaluating the efficacy of TACE in the treatment of

  1. The additive value of transient left ventricular dilation using two-day dipyridamole 99mTc-MIBI SPET for screening coronary artery disease in patients with otherwise normal myocardial perfusion: a comparison between diabetic and non-diabetic cases.

    PubMed

    Fallahi, Babak; Beiki, Davood; Fard-Esfahani, Armaghan; Akbarpour, Saeed; Abolhassani, Arash; Kakhki, Vahid Reza Dabbagh; Eftekhari, Mohammad

    2010-01-01

    The prognostic value of transient ischemic dilation (TID) has been previously confirmed; however, its clinical significance for screening coronary artery disease (CAD) with balanced ischemia, as a cause of false negative myocardial perfusion imaging (MPI), is unclear. The goal of this study was to determine the additive diagnostic value of TID ratio for screening CAD in separate subgroups of diabetic and non-diabetics with normal perfusion. Eighty six patients with intermediate probability of CAD who had TID more than one in the presence of otherwise normal MPI using two-day technetium-99m methoxy isobutyl isonitrile ((99m)Tc-MIBI) single photon emission tomography (SPET) and dipyridamole stress (summed stress score<3 and left ventricular cavity<90 mL) were included in a prospective cohort study comprising two subgroups of diabetic and non- diabetic patients. An inclusive work-up with multiple noninvasive tests was performed for all patients from whom 38 cases subsequently underwent coronary angiography and 48 cases were categorized in the group with a very low likelihood (<5%) of CAD on the basis of clinical and paraclinical data over a minimum of 18 months follow up. The TID ratio was calculated using automated software. Gensini score (GS) as an indicator of severity/extent of stenosis and coronary artery index (CAI) as the number of arteries with more than 50% narrowing were calculated based on angiographic findings. Our results showed that only in diabetic patients with three-vessel disease, TID ratio (1.47 ± 0.23) differs significantly from the other groups of CAD. In diabetic patients subgroup, TID ratio correlated strongly with GS (r=0.957, P<0.0001) and CAI (r=0.659, P=0.001), while such correlations were not seen in the non-diabetic patients. On the basis of receiver operating characteristic curve analysis for screening CAD in diabetic patients with normal myocardial perfusion, 100% sensitivity and 77.8% normalcy rate were achieved when TID more than 1

  2. The added value of hybrid ventilation/perfusion SPECT/CT in patients with stable COPD or apparently healthy smokers. Cancer-suspected CT findings in the lungs are common when hybrid imaging is used.

    PubMed

    Jögi, Jonas; Markstad, Hanna; Tufvesson, Ellen; Bjermer, Leif; Bajc, Marika

    2015-01-01

    Ventilation/perfusion (V/P) single-photon emission computed tomography (SPECT) is recognized as a diagnostic method with potential beyond the diagnosis of pulmonary embolism. V/P SPECT identifies functional impairment in diseases such as heart failure (HF), pneumonia, and chronic obstructive pulmonary disease (COPD). The development of hybrid SPECT/computed tomography (CT) systems, combining functional with morphological imaging through the addition of low-dose CT (LDCT), may be useful in COPD, as these patients are prone to lung cancer and other comorbidities. The aim of this study was to investigate the added value of LDCT among healthy smokers and patients with stable COPD, when examined with V/P SPECT/CT hybrid imaging. Sixty-nine subjects, 55 with COPD (GOLD I-IV) and 14 apparently healthy smokers, were examined with V/P SPECT and LDCT hybrid imaging. Spirometry was used to verify COPD grade. Only one apparently healthy smoker and three COPD patients had a normal or nearly normal V/P SPECT. All other patients showed various degrees of airway obstruction, even when spirometry was normal. The same interpretation was reached on both modalities in 39% of the patients. LDCT made V/P SPECT interpretation more certain in 9% of the patients and, in 52%, LDCT provided additional diagnoses. LDCT better characterized the type of emphysema in 12 patients. In 19 cases, tumor-suspected changes were reported. Three of these 19 patients (ie, 4.3% of all subjects) were in the end confirmed to have lung cancer. The majority of LDCT findings were not regarded as clinically significant. V/P SPECT identified perfusion patterns consistent with decompensated left ventricular HF in 14 COPD patients. In 16 patients (23%), perfusion defects were observed. HF and perfusion defects were not recognized with LDCT. In COPD patients and long-time smokers, hybrid imaging had added value compared to V/P SPECT alone, by identifying patients with lung malignancy and more clearly identifying

  3. Absolute airborne gravimetry

    NASA Astrophysics Data System (ADS)

    Baumann, Henri

    This work consists of a feasibility study of a first stage prototype airborne absolute gravimeter system. In contrast to relative systems, which are using spring gravimeters, the measurements acquired by absolute systems are uncorrelated and the instrument is not suffering from problems like instrumental drift, frequency response of the spring and possible variation of the calibration factor. The major problem we had to resolve were to reduce the influence of the non-gravitational accelerations included in the measurements. We studied two different approaches to resolve it: direct mechanical filtering, and post-processing digital compensation. The first part of the work describes in detail the different mechanical passive filters of vibrations, which were studied and tested in the laboratory and later in a small truck in movement. For these tests as well as for the airborne measurements an absolute gravimeter FG5-L from Micro-G Ltd was used together with an Inertial navigation system Litton-200, a vertical accelerometer EpiSensor, and GPS receivers for positioning. These tests showed that only the use of an optical table gives acceptable results. However, it is unable to compensate for the effects of the accelerations of the drag free chamber. The second part describes the strategy of the data processing. It is based on modeling the perturbing accelerations by means of GPS, EpiSensor and INS data. In the third part the airborne experiment is described in detail, from the mounting in the aircraft and data processing to the different problems encountered during the evaluation of the quality and accuracy of the results. In the part of data processing the different steps conducted from the raw apparent gravity data and the trajectories to the estimation of the true gravity are explained. A comparison between the estimated airborne data and those obtained by ground upward continuation at flight altitude allows to state that airborne absolute gravimetry is feasible and

  4. I-Xe systematics of the impact plume produced chondrules from the CB carbonaceous chondrites: Implications for the half-life value of 129I and absolute age normalization of 129I-129Xe chronometer

    NASA Astrophysics Data System (ADS)

    Pravdivtseva, O.; Meshik, A.; Hohenberg, C. M.; Krot, A. N.

    2017-03-01

    It is inferred that magnesian non-porphyritic chondrules in the CB (Bencubbin-type) carbonaceous chondrites formed in an impact generated plume of gas and melt at 4562.49 ± 0.21 Ma (Bollard et al., 2015) and could be suitable for the absolute age normalization of relative chronometers. Here xenon isotopic compositions of neutron irradiated chondrules from the CB chondrites Gujba and Hammadah al Hamra (HH) 237 have been analyzed in an attempt to determine closure time of their I-Xe isotope systematics. One of the HH 237 chondrules, #1, yielded a well-defined I-Xe isochron that corresponds to a closure time of 0.29 ± 0.16 Ma after the Shallowater aubrite standard. Release profiles and diffusion properties of radiogenic 129*Xe and 128*Xe, extracted from this chondrule by step-wise pyrolysis, indicate presence of two iodine host phases with distinct activation energies of 73 and 120 kcal/mol. In spite of the activation energy differences, the I-Xe isotope systematics of these two phases closed simultaneously, suggesting rapid heating and cooling (possibly quenching) of the CB chondrules. The release profiles of U-fission Xe and I-derived Xe correlate in the high temperature host phase supporting simultaneous closure of 129I-129Xe and 207Pb-206Pb systematics. The absolute I-Xe age of Shallowater standard is derived from the observed correlation between I-Xe and Pb-Pb ages in a number of samples. It is re-evaluated here using Pb-Pb ages adjusted for an updated 238U/235U ratio of 137.794 and meteorite specific U-isotope ratios. With the addition of the new data for HH 237 chondrule #1, the re-evaluated absolute I-Xe age of Shallowater is 4562.4 ± 0.2 Ma. The absolute I-Xe age of the HH 237 chondrule #1 is 4562.1 ± 0.3 Ma, in good agreement with U-corrected Pb-Pb ages of the Gujba chondrules (Bollard et al., 2015) and HH 237 silicates (Krot et al., 2005). All I-Xe data used here, and in previous estimates of the absolute age of Shallowater, are calculated using 15.7

  5. Absolute Equilibrium Entropy

    NASA Technical Reports Server (NTRS)

    Shebalin, John V.

    1997-01-01

    The entropy associated with absolute equilibrium ensemble theories of ideal, homogeneous, fluid and magneto-fluid turbulence is discussed and the three-dimensional fluid case is examined in detail. A sigma-function is defined, whose minimum value with respect to global parameters is the entropy. A comparison is made between the use of global functions sigma and phase functions H (associated with the development of various H-theorems of ideal turbulence). It is shown that the two approaches are complimentary though conceptually different: H-theorems show that an isolated system tends to equilibrium while sigma-functions allow the demonstration that entropy never decreases when two previously isolated systems are combined. This provides a more complete picture of entropy in the statistical mechanics of ideal fluids.

  6. Absolutely classical spin states

    NASA Astrophysics Data System (ADS)

    Bohnet-Waldraff, F.; Giraud, O.; Braun, D.

    2017-01-01

    We introduce the concept of "absolutely classical" spin states, in analogy to absolutely separable states of bipartite quantum systems. Absolutely classical states are states that remain classical (i.e., a convex sum of projectors on coherent states of a spin j ) under any unitary transformation applied to them. We investigate the maximal size of the ball of absolutely classical states centered on the maximally mixed state and derive a lower bound for its radius as a function of the total spin quantum number. We also obtain a numerical estimate of this maximal radius and compare it to the case of absolutely separable states.

  7. TU-A-12A-09: Absolute Blood Flow Measurement in a Cardiac Phantom Using Low Dose CT

    SciTech Connect

    Ziemer, B; Hubbard, L; Lipinski, J; Molloi, S

    2014-06-15

    Purpose: To investigate a first pass analysis technique to measure absolute flow from low dose CT images in a cardiac phantom. This technique can be combined with a myocardial mass assignment to yield absolute perfusion using only two volume scans and reduce the radiation dose to the patient. Methods: A four-chamber cardiac phantom and perfusion chamber were constructed from poly-acrylic and connected with tubing to approximate anatomical features. The system was connected to a pulsatile pump, input/output reservoirs and power contrast injector. Flow was varied in the range of 1-2.67 mL/s with the pump operating at 60 beats/min. The system was imaged once a second for 14 seconds with a 320-row scanner (Toshiba Medical Systems) using a contrast-enhanced, prospective-gated cardiac perfusion protocol. Flow was calculated by the following steps: subsequent images of the perfusion volume were subtracted to find the contrast entering the volume; this was normalized by an upstream, known volume region to convert Hounsfield (HU) values to concentration; this was divided by the subtracted images time difference. The technique requires a relatively stable input contrast concentration and no contrast can leave the perfusion volume before the flow measurement is completed. Results: The flow calculated from the images showed an excellent correlation with the known rates. The data was fit to a linear function with slope 1.03, intercept 0.02 and an R{sup 2} value of 0.99. The average root mean square (RMS) error was 0.15 mL/s and the average standard deviation was 0.14 mL/s. The flow rate was stable within 7.7% across the full scan and served to validate model assumptions. Conclusion: Accurate, absolute flow rates were measured from CT images using a conservation of mass model. Measurements can be made using two volume scans which can substantially reduce the radiation dose compared with current dynamic perfusion techniques.

  8. Comparison of cerebral tissue oxygenation values in full term and preterm newborns by the simultaneous use of two near-infrared spectroscopy devices: an absolute and a relative trending oximeter

    NASA Astrophysics Data System (ADS)

    Szczapa, Tomasz; Karpiński, Łukasz; Moczko, Jerzy; Weindling, Michael; Kornacka, Alicja; Wróblewska, Katarzyna; Adamczak, Aleksandra; Jopek, Aleksandra; Chojnacka, Karolina; Gadzinowski, Janusz

    2013-08-01

    The aim of this study is to compare a two-wavelength light emitting diode-based tissue oximeter (INVOS), which is designed to show trends in tissue oxygenation, with a four-wavelength laser-based oximeter (FORE-SIGHT), designed to deliver absolute values of tissue oxygenation. Simultaneous values of cerebral tissue oxygenation (StO2) are measured using both devices in 15 term and 15 preterm clinically stable newborns on the first and third day of life. Values are recorded simultaneously in two periods between which oximeter sensor positions are switched to the contralateral side. Agreement between StO2 values before and after the change of sensor position is analyzed. We find that mean cerebral StO2 values are similar between devices for term and preterm babies, but INVOS shows StO2 values spread over a wider range, with wider standard deviations than shown by the FORE-SIGHT. There is relatively good agreement with a bias up to 3.5% and limits of agreement up to 11.8%. Measurements from each side of the forehead show better repeatability for the FORE-SIGHT monitor. We conclude that performance of the two devices is probably acceptable for clinical purposes. Both performed sufficiently well, but the use of FORE-SIGHT may be associated with tighter range and better repeatability of data.

  9. Discovery of Cepheids in NGC 5253: Absolute peak brightness of SN Ia 1895B and SN Ia 1972E and the value of H(sub 0)

    NASA Technical Reports Server (NTRS)

    Saha, A.; Sandage, Allan; Labhardt, Lukas; Schwengeler, Hans; Tammann, G. A.; Panagia, N.; Macchetto, F. D.

    1995-01-01

    Observations of the Hubble Space Telescope (HST) between 1993 May 31 and 1993 July 19 in 20 epochs in the F555W passband and five epochs in the F785LP passband have led to the discovery of 14 Cepheids in the Amorphous galaxy NGC 5253. The apparent V distance modulus is (m-M)(sub AV) = 28.08 +/- 0.10 determined from the 12 Cepheids with normal amplitudes. The distance modulus using the F785LP data is consistent with the V value to within the errors. Five methods used to determine the internal reddening are consistent with zero differential reddening, accurate to a level of E(B-V) less than 0.05 mag, over the region occupied by Cepheids and the two supernovae (SNe) produced by NGC 5253. The apparent magnitudes at maximum for the two SNe in NGC 5253 are adopted as B(sub max) = 8.33 +/- 0.2 mag for SN 1895B, and B(sub max) = 8.56 +/- 0.1 and V(sub max) = 8.60 +/- 0.1 for SN 1972E which is a prototype SN of Type Ia. The apparent magnitude system used by Walker (1923) for SN 1859B has been corrected to the modern B scale and zero point to determine its adopted B(sub max) value.

  10. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  11. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  12. Absolute quantification of myocardial blood flow.

    PubMed

    Yoshinaga, Keiichiro; Manabe, Osamu; Tamaki, Nagara

    2016-07-21

    With the increasing availability of positron emission tomography (PET) myocardial perfusion imaging, the absolute quantification of myocardial blood flow (MBF) has become popular in clinical settings. Quantitative MBF provides an important additional diagnostic or prognostic information over conventional visual assessment. The success of MBF quantification using PET/computed tomography (CT) has increased the demand for this quantitative diagnostic approach to be more accessible. In this regard, MBF quantification approaches have been developed using several other diagnostic imaging modalities including single-photon emission computed tomography, CT, and cardiac magnetic resonance. This review will address the clinical aspects of PET MBF quantification and the new approaches to MBF quantification.

  13. Absolute instability of the Gaussian wake profile

    NASA Technical Reports Server (NTRS)

    Hultgren, Lennart S.; Aggarwal, Arun K.

    1987-01-01

    Linear parallel-flow stability theory has been used to investigate the effect of viscosity on the local absolute instability of a family of wake profiles with a Gaussian velocity distribution. The type of local instability, i.e., convective or absolute, is determined by the location of a branch-point singularity with zero group velocity of the complex dispersion relation for the instability waves. The effects of viscosity were found to be weak for values of the wake Reynolds number, based on the center-line velocity defect and the wake half-width, larger than about 400. Absolute instability occurs only for sufficiently large values of the center-line wake defect. The critical value of this parameter increases with decreasing wake Reynolds number, thereby indicating a shrinking region of absolute instability with decreasing wake Reynolds number. If backflow is not allowed, absolute instability does not occur for wake Reynolds numbers smaller than about 38.

  14. Diagnostic Performance of Dual-Energy CT Stress Myocardial Perfusion Imaging: Direct Comparison With Cardiovascular MRI

    PubMed Central

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K.

    2014-01-01

    OBJECTIVE The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. SUBJECTS AND METHODS One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥ 50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemodynamically significant stenosis was assessed before and after stress perfusion DECT on a pervessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. RESULTS The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p = 0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. CONCLUSION Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically

  15. Abdominal perfusion computed tomography.

    PubMed

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-02-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis.

  16. Abdominal Perfusion Computed Tomography

    PubMed Central

    Ogul, Hayri; Bayraktutan, Ummugulsum; Kizrak, Yesim; Pirimoglu, Berhan; Yuceler, Zeynep; Sagsoz, M. Erdem; Yilmaz, Omer; Aydinli, Bulent; Ozturk, Gurkan; Kantarci, Mecit

    2013-01-01

    The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Per-fusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis. PMID:25610249

  17. Quantification of tumor perfusion using dynamic contrast-enhanced ultrasound: impact of mathematical modeling

    NASA Astrophysics Data System (ADS)

    Doury, Maxime; Dizeux, Alexandre; de Cesare, Alain; Lucidarme, Olivier; Pellot-Barakat, Claire; Bridal, S. Lori; Frouin, Frédérique

    2017-02-01

    Dynamic contrast-enhanced ultrasound has been proposed to monitor tumor therapy, as a complement to volume measurements. To assess the variability of perfusion parameters in ideal conditions, four consecutive test-retest studies were acquired in a mouse tumor model, using controlled injections. The impact of mathematical modeling on parameter variability was then investigated. Coefficients of variation (CV) of tissue blood volume (BV) and tissue blood flow (BF) based-parameters were estimated inside 32 sub-regions of the tumors, comparing the log-normal (LN) model with a one-compartment model fed by an arterial input function (AIF) and improved by the introduction of a time delay parameter. Relative perfusion parameters were also estimated by normalization of the LN parameters and normalization of the one-compartment parameters estimated with the AIF, using a reference tissue (RT) region. A direct estimation (rRTd) of relative parameters, based on the one-compartment model without using the AIF, was also obtained by using the kinetics inside the RT region. Results of test-retest studies show that absolute regional parameters have high CV, whatever the approach, with median values of about 30% for BV, and 40% for BF. The positive impact of normalization was established, showing a coherent estimation of relative parameters, with reduced CV (about 20% for BV and 30% for BF using the rRTd approach). These values were significantly lower (p  <  0.05) than the CV of absolute parameters. The rRTd approach provided the smallest CV and should be preferred for estimating relative perfusion parameters.

  18. Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance.

    PubMed

    Chiribiri, Amedeo; Schuster, Andreas; Ishida, Masaki; Hautvast, Gilion; Zarinabad, Niloufar; Morton, Geraint; Otton, James; Plein, Sven; Breeuwer, Marcel; Batchelor, Philip; Schaeffter, Tobias; Nagel, Eike

    2013-03-01

    The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to controlled variations of myocardial perfusion rate, contrast agent dose, and cardiac output. It produced distinct signal intensity curves for perfusion rates ranging from 1 to 10 mL/mL/min. Quantification of myocardial blood flow by signal deconvolution techniques provided accurate measurements of perfusion. The phantom also proved to be very reproducible between different sessions and different operators. This novel hardware perfusion phantom system allows reliable, reproducible, and efficient simulation of myocardial first-pass MR perfusion. Direct comparison between the results of image-based quantification and reference values of flow and myocardial perfusion will allow development and validation of accurate quantification methods.

  19. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  20. PREOPERATIVE PREDICTION OF LUNG FUNCTION IN PNEUMONECTOMY BY SPIROMETRY AND LUNG PERFUSION SCINTIGRAPHY

    PubMed Central

    Cukic, Vesna

    2012-01-01

    Introduction: Nowadays an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused by common etiologic factor - smoking cigarettes. Loss of lung tissue in such patients can worsen much the postoperative pulmonary function. So it is necessary to asses the postoperative pulmonary function especially after maximal resection, i.e. pneumonectomy. Objective: To check over the accuracy of preoperative prognosis of postoperative lung function after pneumonectomy using spirometry and lung perfusion scinigraphy. Material and methods: The study was done on 17 patients operated at the Clinic for thoracic surgery, who were treated previously at the Clinic for Pulmonary Diseases “Podhrastovi” in the period from 01. 12. 2008. to 01. 06. 2011. Postoperative pulmonary function expressed as ppoFEV1 (predicted postoperative forced expiratory volume in one second) was prognosticated preoperatively using spirometry, i.e.. simple calculation according to the number of the pulmonary segments to be removed and perfusion lung scintigraphy. Results: There is no significant deviation of postoperative achieved values of FEV1 from predicted ones obtained by both methods, and there is no significant differences between predicted values (ppoFEV1) obtained by spirometry and perfusion scintigraphy. Conclusion: It is necessary to asses the postoperative pulmonary function before lung resection to avoid postoperative respiratory failure and other cardiopulmonary complications. It is absolutely necessary for pneumonectomy, i.e.. maximal pulmonary resection. It can be done with great possibility using spirometry or perfusion lung scintigraphy. PMID:23378687

  1. Absolute and relative blindsight.

    PubMed

    Balsdon, Tarryn; Azzopardi, Paul

    2015-03-01

    The concept of relative blindsight, referring to a difference in conscious awareness between conditions otherwise matched for performance, was introduced by Lau and Passingham (2006) as a way of identifying the neural correlates of consciousness (NCC) in fMRI experiments. By analogy, absolute blindsight refers to a difference between performance and awareness regardless of whether it is possible to match performance across conditions. Here, we address the question of whether relative and absolute blindsight in normal observers can be accounted for by response bias. In our replication of Lau and Passingham's experiment, the relative blindsight effect was abolished when performance was assessed by means of a bias-free 2AFC task or when the criterion for awareness was varied. Furthermore, there was no evidence of either relative or absolute blindsight when both performance and awareness were assessed with bias-free measures derived from confidence ratings using signal detection theory. This suggests that both relative and absolute blindsight in normal observers amount to no more than variations in response bias in the assessment of performance and awareness. Consideration of the properties of psychometric functions reveals a number of ways in which relative and absolute blindsight could arise trivially and elucidates a basis for the distinction between Type 1 and Type 2 blindsight.

  2. A multi-centennial time series of well-constrained ΔR values for the Irish Sea derived using absolutely-dated shell samples from the mollusc Arctica islandica

    NASA Astrophysics Data System (ADS)

    Butler, P. G.; Scourse, J. D.; Richardson, C. A.; Wanamaker, A. D., Jr.

    2009-04-01

    Determinations of the local correction (ΔR) to the globally averaged marine radiocarbon reservoir age are often isolated in space and time, derived from heterogeneous sources and constrained by significant uncertainties. Although time series of ΔR at single sites can be obtained from sediment cores, these are subject to multiple uncertainties related to sedimentation rates, bioturbation and interspecific variations in the source of radiocarbon in the analysed samples. Coral records provide better resolution, but these are available only for tropical locations. It is shown here that it is possible to use the shell of the long-lived bivalve mollusc Arctica islandica as a source of high resolution time series of absolutely-dated marine radiocarbon determinations for the shelf seas surrounding the North Atlantic ocean. Annual growth increments in the shell can be crossdated and chronologies can be constructed in a precise analogue with the use of tree-rings. Because the calendar dates of the samples are known, ΔR can be determined with high precision and accuracy and because all the samples are from the same species, the time series of ΔR values possesses a high degree of internal consistency. Presented here is a multi-centennial (AD 1593 - AD 1933) time series of 31 ΔR values for a site in the Irish Sea close to the Isle of Man. The mean value of ΔR (-62 14C yrs) does not change significantly during this period but increased variability is apparent before AD 1750.

  3. Absolute neutrino mass scale

    NASA Astrophysics Data System (ADS)

    Capelli, Silvia; Di Bari, Pasquale

    2013-04-01

    Neutrino oscillation experiments firmly established non-vanishing neutrino masses, a result that can be regarded as a strong motivation to extend the Standard Model. In spite of being the lightest massive particles, neutrinos likely represent an important bridge to new physics at very high energies and offer new opportunities to address some of the current cosmological puzzles, such as the matter-antimatter asymmetry of the Universe and Dark Matter. In this context, the determination of the absolute neutrino mass scale is a key issue within modern High Energy Physics. The talks in this parallel session well describe the current exciting experimental activity aiming to determining the absolute neutrino mass scale and offer an overview of a few models beyond the Standard Model that have been proposed in order to explain the neutrino masses giving a prediction for the absolute neutrino mass scale and solving the cosmological puzzles.

  4. Quantitative myocardial perfusion SPECT.

    PubMed

    Tsui, B M; Frey, E C; LaCroix, K J; Lalush, D S; McCartney, W H; King, M A; Gullberg, G T

    1998-01-01

    In recent years, there has been much interest in the clinical application of attenuation compensation to myocardial perfusion single photon emission computed tomography (SPECT) with the promise that accurate quantitative images can be obtained to improve clinical diagnoses. The different attenuation compensation methods that are available create confusion and some misconceptions. Also, attenuation-compensated images reveal other image-degrading effects including collimator-detector blurring and scatter that are not apparent in uncompensated images. This article presents basic concepts of the major factors that degrade the quality and quantitative accuracy of myocardial perfusion SPECT images, and includes a discussion of the various image reconstruction and compensation methods and misconceptions and pitfalls in implementation. The differences between the various compensation methods and their performance are demonstrated. Particular emphasis is directed to an approach that promises to provide quantitative myocardial perfusion SPECT images by accurately compensating for the 3-dimensional (3-D) attenuation, collimator-detector response, and scatter effects. With advances in the computer hardware and optimized implementation techniques, quantitatively accurate and high-quality myocardial perfusion SPECT images can be obtained in clinically acceptable processing time. Examples from simulation, phantom, and patient studies are used to demonstrate the various aspects of the investigation. We conclude that quantitative myocardial perfusion SPECT, which holds great promise to improve clinical diagnosis, is an achievable goal in the near future.

  5. The absolute path command

    SciTech Connect

    Moody, A.

    2012-05-11

    The ap command traveres all symlinks in a given file, directory, or executable name to identify the final absolute path. It can print just the final path, each intermediate link along with the symlink chan, and the permissions and ownership of each directory component in the final path. It has functionality similar to "which", except that it shows the final path instead of the first path. It is also similar to "pwd", but it can provide the absolute path to a relative directory from the current working directory.

  6. [Ocular perfusion pressure and its relevance for glaucoma].

    PubMed

    Schmidl, D; Werkmeister, R; Garhöfer, G; Schmetterer, L

    2015-02-01

    Ocular perfusion pressure is defined as the difference between arterial and venous pressure in ocular vessels. In practice, mean arterial pressure is used to substitute for arterial pressure in ocular vessels while intraocular pressure gives an estimate for ocular venous pressure. This results in a value that is easy to calculate and which is of importance since several studies have shown that it is correlated to the prevalence, incidence and progression of primary open angle glaucoma. Today, ocular perfusion pressure is used to estimate individual risks. Since no target value for ocular perfusion pressure can be defined, direct therapeutic intervention is difficult. Still, it has to be kept in mind that lowering intraocular pressure automatically leads to an increase in ocular perfusion pressure. The present article also points out problems and limitations in the concept of ocular perfusion pressure and suggests possible solutions for these problems in the future.

  7. Ex vivo lung perfusion.

    PubMed

    Reeb, Jeremie; Cypel, Marcelo

    2016-03-01

    Lung transplantation is an established life-saving therapy for patients with end-stage lung disease. Unfortunately, greater success in lung transplantation is hindered by a shortage of lung donors and the relatively poor early-, mid-, and long-term outcomes associated with severe primary graft dysfunction. Ex vivo lung perfusion has emerged as a modern preservation technique that allows for a more accurate lung assessment and improvement in lung quality. This review outlines the: (i) rationale behind the method; (ii) techniques and protocols; (iii) Toronto ex vivo lung perfusion method; (iv) devices available; and (v) clinical experience worldwide. We also highlight the potential of ex vivo lung perfusion in leading a new era of lung preservation.

  8. Absolute calibration of optical tweezers

    SciTech Connect

    Viana, N.B.; Mazolli, A.; Maia Neto, P.A.; Nussenzveig, H.M.; Rocha, M.S.; Mesquita, O.N.

    2006-03-27

    As a step toward absolute calibration of optical tweezers, a first-principles theory of trapping forces with no adjustable parameters, corrected for spherical aberration, is experimentally tested. Employing two very different setups, we find generally very good agreement for the transverse trap stiffness as a function of microsphere radius for a broad range of radii, including the values employed in practice, and at different sample chamber depths. The domain of validity of the WKB ('geometrical optics') approximation to the theory is verified. Theoretical predictions for the trapping threshold, peak position, depth variation, multiple equilibria, and 'jump' effects are also confirmed.

  9. [Portable peristaltic perfusion pumps].

    PubMed

    Magallón Pedrera, I; Soto Torres, I

    1999-11-01

    Portable peristaltic perfusion pumps allow one to administer pharmaceuticals in hospitals as well as in primary health care centers and furthermore these pumps present multiple advantages for patients and their families since they make it possible to carry out treatment in a patient's home while at the same time lowering the costs involved. The authors analyze the most out standing aspects of portable peristaltic perfusion pumps along with their characteristics, installation, programming, and how to turn them on; in addition, the authors list the maintenance care which these pumps require.

  10. Continuous monitoring of absolute cerebral blood flow by combining diffuse correlation spectroscopy and time-resolved near-infrared technology

    NASA Astrophysics Data System (ADS)

    Diop, Mamadou; Lee, Ting-Yim; St. Lawrence, Keith

    2011-02-01

    Continuous bedside monitoring of cerebral blood flow (CBF) in patients recovering from brain injury could improve the detection of impaired substrate delivery, which can exacerbate injury and worsen outcome. Diffuse correlation spectroscopy (DCS) provides the ability to monitor perfusion changes continuously, but it is difficult to quantify absolute blood flow - leading to uncertainties as to whether or not CBF has fallen to ischemic levels. To continuously measure CBF, we propose to calibrate DCS data using a single time-point, time-resolved near-infrared (TR-NIR) technique for measuring absolute CBF. Experiments were conducted on newborn piglets in which CBF was increased by raising the arterial tension of CO2 (40-62 mmHg) and decreased by carotid occlusion. For validation, values of CBF measured by TR-NIR were converted into blood flow changes and compared to CBF changes measured by DCS. A strong correlation between perfusion changes from the two techniques was revealed (slope = 0.98 and R2 = 0.96), suggesting that a single time-point CBF measurement by TR-NIR can be used to convert continuous DCS data into units of CBF (ml/100g/min).

  11. Relative indexes of cutaneous blood perfusion measured by real-time laser Doppler imaging (LDI) in healthy volunteers.

    PubMed

    Seyed Jafari, S Morteza; Schawkat, Megir; Van De Ville, Dimitri; Shafighi, Maziar

    2014-07-01

    We used real-time LDI to study regional variations in microcirculatory perfusion in healthy candidates to establish a new methodology for global perfusion body mapping that is based on intra-individual perfusion index ratios. Our study included 74 (37 female) healthy volunteers aged between 22 and 30 years (mean 24.49). Imaging was performed using a recent microcirculation-imaging camera (EasyLDI) for different body regions of each volunteer. The perfusion values were reported in Arbitrary Perfusion Units (APU). The relative perfusion indexes for each candidate's body region were then obtained by normalization with the perfusion value of the forehead. Basic parameters such as weight, height, and blood pressure were also measured and analyzed. The highest mean perfusion value was reported in the forehead area (259.21APU). Mean perfusion in the measured parts of the body correlated positively with mean forehead value, while there was no significant correlation between forehead blood perfusion values and room temperature, BMI, systolic blood pressure and diastolic blood pressure (p=0.420, 0.623, 0.488, 0.099, respectively). Analysis of the data showed that perfusion indexes were not significantly different between male and female volunteers except for the ventral upper arm area (p=.001). LDI is a non-invasive, fast technique that opens several avenues for clinical applications. The mean perfusion indexes are useful in clinical practice for monitoring patients before and after surgical interventions. Perfusion values can be predicted for different body parts for patients only by taking the forehead perfusion value and using the perfusion index ratios to obtain expected normative perfusion values.

  12. Electronic Absolute Cartesian Autocollimator

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.

    2006-01-01

    An electronic absolute Cartesian autocollimator performs the same basic optical function as does a conventional all-optical or a conventional electronic autocollimator but differs in the nature of its optical target and the manner in which the position of the image of the target is measured. The term absolute in the name of this apparatus reflects the nature of the position measurement, which, unlike in a conventional electronic autocollimator, is based absolutely on the position of the image rather than on an assumed proportionality between the position and the levels of processed analog electronic signals. The term Cartesian in the name of this apparatus reflects the nature of its optical target. Figure 1 depicts the electronic functional blocks of an electronic absolute Cartesian autocollimator along with its basic optical layout, which is the same as that of a conventional autocollimator. Referring first to the optical layout and functions only, this or any autocollimator is used to measure the compound angular deviation of a flat datum mirror with respect to the optical axis of the autocollimator itself. The optical components include an illuminated target, a beam splitter, an objective or collimating lens, and a viewer or detector (described in more detail below) at a viewing plane. The target and the viewing planes are focal planes of the lens. Target light reflected by the datum mirror is imaged on the viewing plane at unit magnification by the collimating lens. If the normal to the datum mirror is parallel to the optical axis of the autocollimator, then the target image is centered on the viewing plane. Any angular deviation of the normal from the optical axis manifests itself as a lateral displacement of the target image from the center. The magnitude of the displacement is proportional to the focal length and to the magnitude (assumed to be small) of the angular deviation. The direction of the displacement is perpendicular to the axis about which the

  13. Absolute-structure reports.

    PubMed

    Flack, Howard D

    2013-08-01

    All the 139 noncentrosymmetric crystal structures published in Acta Crystallographica Section C between January 2011 and November 2012 inclusive have been used as the basis of a detailed study of the reporting of absolute structure. These structure determinations cover a wide range of space groups, chemical composition and resonant-scattering contribution. Defining A and D as the average and difference of the intensities of Friedel opposites, their level of fit has been examined using 2AD and selected-D plots. It was found, regardless of the expected resonant-scattering contribution to Friedel opposites, that the Friedel-difference intensities are often dominated by random uncertainty and systematic error. An analysis of data collection strategy is provided. It is found that crystal-structure determinations resulting in a Flack parameter close to 0.5 may not necessarily be from crystals twinned by inversion. Friedifstat is shown to be a robust estimator of the resonant-scattering contribution to Friedel opposites, very little affected by the particular space group of a structure nor by the occupation of special positions. There is considerable confusion in the text of papers presenting achiral noncentrosymmetric crystal structures. Recommendations are provided for the optimal way of treating noncentrosymmetric crystal structures for which the experimenter has no interest in determining the absolute structure.

  14. Magnetic resonance cardiac perfusion imaging-a clinical perspective.

    PubMed

    Hunold, Peter; Schlosser, Thomas; Barkhausen, Jörg

    2006-08-01

    Coronary artery disease (CAD) with its clinical appearance of stable or unstable angina and acute myocardial infarction is the leading cause of death in developed countries. In view of increasing costs and the rising number of CAD patients, there has been a major interest in reliable non-invasive imaging techniques to identify CAD in an early (i.e. asymptomatic) stage. Since myocardial perfusion deficits appear very early in the "ischemic cascade", a major breakthrough would be the non-invasive quantification of myocardial perfusion before functional impairment might be detected. Therefore, there is growing interest in other, target-organ-specific parameters, such as relative and absolute myocardial perfusion imaging. Magnetic resonance (MR) imaging has been proven to offer attractive concepts in this respect. However, some important difficulties have not been resolved so far, which still causes uncertainty and prevents the broad application of MR perfusion imaging in a clinical setting. This review explores recent technical developments in MR hardware, software and contrast agents, as well as their impact on the current and future clinical status of MR imaging of first-pass myocardial perfusion imaging.

  15. Absolute multilateration between spheres

    NASA Astrophysics Data System (ADS)

    Muelaner, Jody; Wadsworth, William; Azini, Maria; Mullineux, Glen; Hughes, Ben; Reichold, Armin

    2017-04-01

    Environmental effects typically limit the accuracy of large scale coordinate measurements in applications such as aircraft production and particle accelerator alignment. This paper presents an initial design for a novel measurement technique with analysis and simulation showing that that it could overcome the environmental limitations to provide a step change in large scale coordinate measurement accuracy. Referred to as absolute multilateration between spheres (AMS), it involves using absolute distance interferometry to directly measure the distances between pairs of plain steel spheres. A large portion of each sphere remains accessible as a reference datum, while the laser path can be shielded from environmental disturbances. As a single scale bar this can provide accurate scale information to be used for instrument verification or network measurement scaling. Since spheres can be simultaneously measured from multiple directions, it also allows highly accurate multilateration-based coordinate measurements to act as a large scale datum structure for localized measurements, or to be integrated within assembly tooling, coordinate measurement machines or robotic machinery. Analysis and simulation show that AMS can be self-aligned to achieve a theoretical combined standard uncertainty for the independent uncertainties of an individual 1 m scale bar of approximately 0.49 µm. It is also shown that combined with a 1 µm m‑1 standard uncertainty in the central reference system this could result in coordinate standard uncertainty magnitudes of 42 µm over a slender 1 m by 20 m network. This would be a sufficient step change in accuracy to enable next generation aerospace structures with natural laminar flow and part-to-part interchangeability.

  16. Low dose CT perfusion using k-means clustering

    NASA Astrophysics Data System (ADS)

    Pisana, Francesco; Henzler, Thomas; Schönberg, Stefan; Klotz, Ernst; Schmidt, Bernhard; Kachelrieß, Marc

    2016-03-01

    We aim at improving low dose CT perfusion functional parameters maps and CT images quality, preserving quantitative information. In a dynamic CT perfusion dataset, each voxel is measured T times, where T is the number of acquired time points. In this sense, we can think about a voxel as a point in a T-dimensional space, where the coordinates of the voxels would be the values of its time attenuation curve (TAC). Starting from this idea, a k-means algorithm was designed to group voxels in K classes. A modified guided time-intensity profile similarity (gTIPS) filter was implemented and applied only for those voxels belonging to the same class. The approach was tested on a digital brain perfusion phantom as well as on clinical brain and body perfusion datasets, and compared to the original TIPS implementation. The TIPS filter showed the highest CNR improvement, but lowest spatial resolution. gTIPS proved to have the best combination of spatial resolution and CNR improvement for CT images, while k-gTIPS was superior to both gTIPS and TIPS in terms of perfusion maps image quality. We demonstrate k-means clustering analysis can be applied to denoise dynamic CT perfusion data and to improve functional maps. Beside the promising results, this approach has the major benefit of being independent from the perfusion model employed for functional parameters calculation. No similar approaches were found in literature.

  17. Measurement of absolute arterial cerebral blood volume in human brain without using a contrast agent.

    PubMed

    Hua, Jun; Qin, Qin; Pekar, James J; van Zijl, Peter C M

    2011-12-01

    Arterial cerebral blood volume (CBV(a) ) is a vital indicator of tissue perfusion and vascular reactivity. We extended the recently developed inflow vascular-space-occupancy (iVASO) MRI technique, which uses spatially selective inversion to suppress the signal from blood flowing into a slice, with a control scan to measure absolute CBV(a) using cerebrospinal fluid (CSF) for signal normalization. Images were acquired at multiple blood nulling times to account for the heterogeneity of arterial transit times across the brain, from which both CBV(a) and arterial transit times were quantified. Arteriolar CBV(a) was determined separately by incorporating velocity-dependent bipolar crusher gradients. Gray matter (GM) CBV(a) values (n=11) were 2.04 ± 0.27 and 0.76 ± 0.17 ml blood/100 ml tissue without and with crusher gradients (b=1.8 s/mm(2) ), respectively. Arterial transit times were 671 ± 43 and 785 ± 69 ms, respectively. The arterial origin of the signal was validated by measuring its T(2) , which was within the arterial range. The proposed approach does not require exogenous contrast agent administration, and provides a non-invasive alternative to existing blood volume techniques for mapping absolute CBV(a) in studies of brain physiology and neurovascular diseases.

  18. Automated prediction of tissue outcome after acute ischemic stroke in computed tomography perfusion images

    NASA Astrophysics Data System (ADS)

    Vos, Pieter C.; Bennink, Edwin; de Jong, Hugo; Velthuis, Birgitta K.; Viergever, Max A.; Dankbaar, Jan Willem

    2015-03-01

    Assessment of the extent of cerebral damage on admission in patients with acute ischemic stroke could play an important role in treatment decision making. Computed tomography perfusion (CTP) imaging can be used to determine the extent of damage. However, clinical application is hindered by differences among vendors and used methodology. As a result, threshold based methods and visual assessment of CTP images has not yet shown to be useful in treatment decision making and predicting clinical outcome. Preliminary results in MR studies have shown the benefit of using supervised classifiers for predicting tissue outcome, but this has not been demonstrated for CTP. We present a novel method for the automatic prediction of tissue outcome by combining multi-parametric CTP images into a tissue outcome probability map. A supervised classification scheme was developed to extract absolute and relative perfusion values from processed CTP images that are summarized by a trained classifier into a likelihood of infarction. Training was performed using follow-up CT scans of 20 acute stroke patients with complete recanalization of the vessel that was occluded on admission. Infarcted regions were annotated by expert neuroradiologists. Multiple classifiers were evaluated in a leave-one-patient-out strategy for their discriminating performance using receiver operating characteristic (ROC) statistics. Results showed that a RandomForest classifier performed optimally with an area under the ROC of 0.90 for discriminating infarct tissue. The obtained results are an improvement over existing thresholding methods and are in line with results found in literature where MR perfusion was used.

  19. Harmonic analysis of perfusion pumps.

    PubMed

    Dougherty, F Carroll; Donovan, F M; Townsley, Mary I

    2003-12-01

    The controversy over the use of nonpulsatile versus pulsatile pumps for maintenance of normal organ function during ex vivo perfusion has continued for many years, but resolution has been limited by lack of a congruent mathematical definition of pulsatility. We hypothesized that the waveform frequency and amplitude, as well as the underlying mean distending pressure are all key parameters controlling vascular function. Using discrete Fourier Analysis, our data demonstrate the complexity of the pulmonary arterial pressure waveform in vivo and the failure of commonly available perfusion pumps to mimic in vivo dynamics. In addition, our data show that the key harmonic signatures are intrinsic to the perfusion pumps, are similar for flow and pressure waveforms, and are unchanged by characteristics of the downstream perfusion circuit or perfusate viscosity.

  20. Estimating Absolute Site Effects

    SciTech Connect

    Malagnini, L; Mayeda, K M; Akinci, A; Bragato, P L

    2004-07-15

    The authors use previously determined direct-wave attenuation functions as well as stable, coda-derived source excitation spectra to isolate the absolute S-wave site effect for the horizontal and vertical components of weak ground motion. They used selected stations in the seismic network of the eastern Alps, and find the following: (1) all ''hard rock'' sites exhibited deamplification phenomena due to absorption at frequencies ranging between 0.5 and 12 Hz (the available bandwidth), on both the horizontal and vertical components; (2) ''hard rock'' site transfer functions showed large variability at high-frequency; (3) vertical-motion site transfer functions show strong frequency-dependence, and (4) H/V spectral ratios do not reproduce the characteristics of the true horizontal site transfer functions; (5) traditional, relative site terms obtained by using reference ''rock sites'' can be misleading in inferring the behaviors of true site transfer functions, since most rock sites have non-flat responses due to shallow heterogeneities resulting from varying degrees of weathering. They also use their stable source spectra to estimate total radiated seismic energy and compare against previous results. they find that the earthquakes in this region exhibit non-constant dynamic stress drop scaling which gives further support for a fundamental difference in rupture dynamics between small and large earthquakes. To correct the vertical and horizontal S-wave spectra for attenuation, they used detailed regional attenuation functions derived by Malagnini et al. (2002) who determined frequency-dependent geometrical spreading and Q for the region. These corrections account for the gross path effects (i.e., all distance-dependent effects), although the source and site effects are still present in the distance-corrected spectra. The main goal of this study is to isolate the absolute site effect (as a function of frequency) by removing the source spectrum (moment-rate spectrum) from

  1. Reversible changes in diffusion- and perfusion-based imaging in cerebral venous sinus thrombosis.

    PubMed

    Lin, Ning; Wong, Andrew K; Lipinski, Lindsay J; Mokin, Maxim; Siddiqui, Adnan H

    2016-02-01

    Diffusion- and perfusion-based imaging studies are regularly used in patients with ischemic stroke. Cerebral venous sinus thrombosis (CVST) is a rare cause of stroke and is primarily treated by systemic anticoagulation. Endovascular intervention can be considered in cases of failed medical therapy, yet the prognostic value of diffusion- and perfusion-based imaging for CVST has not been clearly established. We present a patient with CVST whose abnormal findings on MRI and CT perfusion images were largely reversed after endovascular treatment.

  2. Ex vivo lung perfusion

    PubMed Central

    Machuca, Tiago N.

    2014-01-01

    Lung transplantation (LTx) is an established treatment option for eligible patients with end-stage lung disease. Nevertheless, the imbalance between suitable donor lungs available and the increasing number of patients considered for LTx reflects in considerable waitlist mortality. Among potential alternatives to address this issue, ex vivo lung perfusion (EVLP) has emerged as a modern preservation technique that allows for more accurate lung assessment and also improvement of lung function. Its application in high-risk donor lungs has been successful and resulted in safe expansion of the donor pool. This article will: (I) review the technical details of EVLP; (II) the rationale behind the method; (III) report the worldwide clinical experience with the EVLP, including the Toronto technique and others; (IV) finally, discuss the growing literature on EVLP application for donation after cardiac death (DCD) lungs. PMID:25132972

  3. Eosinophil count - absolute

    MedlinePlus

    ... or 0.50 x 10^9/L. Normal value ranges may vary slightly among different laboratories. Talk to your doctor about the meaning of your specific test results. The example above shows the common measurements for results of these tests. Some laboratories use ...

  4. Determination of regional myocardial perfusion by x-ray fluorescence

    SciTech Connect

    Palmer, B.M.; McInerney, J.J. )

    1990-05-01

    Validation studies were performed to demonstrate the effectiveness of an x-ray induced fluorescence system in quantitating regional myocardial perfusion in vivo. In a series of 13 open-chested canines, x-ray induced fluorescence was used to simultaneously monitor iodine concentration transients which arose in the left ventricular lumen and in the myocardium after the intravenous injection of an iodinated flow tracer. Deconvolution of the recorded transients produced a transfer function from which the mean transit time for the tracer to travel between the left ventricular lumen and the myocardium was calculated. Measurements of regional myocardial perfusion (Q) made by radioactive microspheres were compared with the reciprocals of the mean transit times (MTT-1) and gave a linear correlation (n = 38): MTT-1 = 0.033 + 0.069 Q, r = 0.71. Comparison of the percent change in perfusion (dQ) relative to a control study for each dog with the percent change in the respective reciprocals of the mean transit times (dMTT-1) produced a linear correlation coefficient of r = 0.88 for the regression line dMTT-1 = 0.46 dQ - 10.7. The x-ray induced fluorescence system may provide a minimally invasive means for monitoring iodine concentration transients and determining relative, if not absolute, measures of regional myocardial perfusion.

  5. Cerebral-Body Perfusion Model

    DTIC Science & Technology

    1990-07-01

    compared to the 0.5g curve) fall in flow. Fig. 9b, showing the 5g case, strongly suggests a possible, so-called, " luxury perfusion ", in which natural...as the luxury perfusion situation which bypasses the flow with the nutrients it carries (through newly opened collaterals) and result in a "blackout...89-0054 CEREBRAL-BODY PERFUSION MODEL S. Sorek’, J. Bear2, and M., Feinsod3 in Collaboration with K. Allen4, L. Bunt5 and S. Ben-IHaiM6 July 1990

  6. Asteroid absolute magnitudes and slope parameters

    NASA Technical Reports Server (NTRS)

    Tedesco, Edward F.

    1991-01-01

    A new listing of absolute magnitudes (H) and slope parameters (G) has been created and published in the Minor Planet Circulars; this same listing will appear in the 1992 Ephemerides of Minor Planets. Unlike previous listings, the values of the current list were derived from fits of data at the V band. All observations were reduced in the same fashion using, where appropriate, a single basis default value of 0.15 for the slope parameter. Distances and phase angles were computed for each observation. The data for 113 asteroids was of sufficiently high quality to permit derivation of their H and G. These improved absolute magnitudes and slope parameters will be used to deduce the most reliable bias-corrected asteroid size-frequency distribution yet made.

  7. Probing absolute spin polarization at the nanoscale.

    PubMed

    Eltschka, Matthias; Jäck, Berthold; Assig, Maximilian; Kondrashov, Oleg V; Skvortsov, Mikhail A; Etzkorn, Markus; Ast, Christian R; Kern, Klaus

    2014-12-10

    Probing absolute values of spin polarization at the nanoscale offers insight into the fundamental mechanisms of spin-dependent transport. Employing the Zeeman splitting in superconducting tips (Meservey-Tedrow-Fulde effect), we introduce a novel spin-polarized scanning tunneling microscopy that combines the probing capability of the absolute values of spin polarization with precise control at the atomic scale. We utilize our novel approach to measure the locally resolved spin polarization of magnetic Co nanoislands on Cu(111). We find that the spin polarization is enhanced by 65% when increasing the width of the tunnel barrier by only 2.3 Å due to the different decay of the electron orbitals into vacuum.

  8. Ex vivo normothermic machine perfusion and viability testing of discarded human donor livers.

    PubMed

    op den Dries, S; Karimian, N; Sutton, M E; Westerkamp, A C; Nijsten, M W N; Gouw, A S H; Wiersema-Buist, J; Lisman, T; Leuvenink, H G D; Porte, R J

    2013-05-01

    In contrast to traditional static cold preservation of donor livers, normothermic machine perfusion may reduce preservation injury, improve graft viability and potentially allows ex vivo assessment of graft viability before transplantation. We have studied the feasibility of normothermic machine perfusion in four discarded human donor livers. Normothermic machine perfusion consisted of pressure and temperature controlled pulsatile perfusion of the hepatic artery and continuous portal perfusion for 6 h. Two hollow fiber membrane oxygenators provided oxygenation of the perfusion fluid. Biochemical markers in the perfusion fluid reflected minimal hepatic injury and improving function. Lactate levels decreased to normal values, reflecting active metabolism by the liver (mean lactate 10.0 ± 2.3 mmol/L at 30 min to 2.3 ± 1.2 mmol/L at 6 h). Bile production was observed throughout the 6 h perfusion period (mean rate 8.16 ± 0.65 g/h after the first hour). Histological examination before and after 6 h of perfusion showed well-preserved liver morphology without signs of additional hepatocellular ischemia, biliary injury or sinusoidal damage. In conclusion, this study shows that normothermic machine perfusion of human donor livers is technically feasible. It allows assessment of graft viability before transplantation, which opens new avenues for organ selection, therapeutic interventions and preconditioning.

  9. A new formalism for the quantification of tissue perfusion by the destruction-replenishment method in contrast ultrasound imaging.

    PubMed

    Arditi, Marcel; Frinking, Peter J A; Zhou, Xiang; Rognin, Nicolas G

    2006-06-01

    A new formalism is presented for the destruction-replenishment perfusion quantification approach at low mechanical index. On the basis of physical considerations, best-fit methods should be applied using perfusion functions with S-shape characteristics. These functions are first described for the case of a geometry with a single flow velocity, then extended to the case of vascular beds with blood vessels having multiple flow velocity values and directions. The principles guiding the analysis are, on one hand, a linearization of video echo signals to overcome the log-compression of the imaging instrument, and, on the other hand, the spatial distribution of the transmit-receive ultrasound beam in the elevation direction. An in vitro model also is described; it was used to confirm experimentally the validity of the approach using a commercial contrast agent. The approach was implemented in the form of a computer program, taking as input a sequence of contrast-specific images, as well as parameters related to the ultrasound imaging equipment used. The generated output is either flow-parameter values computed in regions-of-interest, or parametric flow-images (e.g., mean velocity, mean transit time, mean flow, flow variance, or skewness). This approach thus establishes a base for extracting information about the morphology of vascular beds in vivo, and could allow absolute quantification provided that appropriate instrument calibration is implemented.

  10. Pulmonary ventilation/perfusion scan

    MedlinePlus

    ... JavaScript. A pulmonary ventilation/perfusion scan involves two nuclear scan tests to measure breathing (ventilation) and circulation ( ... In: Mettler FA, Guiberteau MJ, eds. Essentials of Nuclear Medicine Imaging . 6th ed. Philadelphia, PA: Elsevier Saunders; ...

  11. Measuring the absolute magnetic field using high-Tc SQUID

    NASA Astrophysics Data System (ADS)

    He, D. F.; Itozaki, H.

    2006-06-01

    SQUID normally can only measure the change of magnetic field instead of the absolute value of magnetic field. Using a compensation method, a mobile SQUID, which could keep locked when moving in the earth's magnetic field, was developed. Using the mobile SQUID, it was possible to measure the absolute magnetic field. The absolute value of magnetic field could be calculated from the change of the compensation output when changing the direction of the SQUID in a magnetic field. Using this method and the mobile SQUID, we successfully measured the earth's magnetic field in our laboratory.

  12. CAD of myocardial perfusion

    NASA Astrophysics Data System (ADS)

    Storm, Corstiaan J.; Slump, Cornelis H.

    2007-03-01

    Our purpose is in the automated evaluation of the physiological relevance of lesions in coronary angiograms. We aim to extract as much as possible quantitative information about the physiological condition of the heart from standard angiographic image sequences. Coronary angiography is still the gold standard for evaluating and diagnosing coronary abnormalities as it is able to locate precisely the coronary artery lesions. The dimensions of the stenosis can be assessed nowadays successfully with image processing based Quantitative Coronary Angiography (QCA) techniques. Our purpose is to assess the clinical relevance of the pertinent stenosis. We therefore analyze the myocardial perfusion as revealed in standard angiographic image sequences. In a Region-of-Interest (ROI) on the angiogram (without an overlaying major blood vessel) the contrast is measured as a function of time (the so-called time-density curve). The required hyperemic state of exercise is induced artificially by the injection of a vasodilator drug e.g. papaverine. In order to minimize motion artifacts we select based on the recorded ECG signal end-diastolic images in both a basal and a hyperemic run in the same projection to position the ROI. We present the development of the algorithms together with results of a small study of 20 patients which have been catheterized following the standard protocol.

  13. Parametric perfusion imaging based on low-cost ultrasound platform.

    PubMed

    Gu, Xiaolin; Zhong, Hui; Wan, Mingxi; Hu, Xiaowen; Lv, Dan; Shen, Liang; Zhang, Xiaomei

    2010-01-01

    In this study, we attempted to implement parametric perfusion imaging to quantify blood perfusion based on modified low-cost ultrasound platform. A novel ultrasound contrast-specific imaging method called pulse-inversion harmonic sum-squared-differences (PIHSSD) was proposed for improving the sensitivity for detecting contrast agents and the accuracy of parametric perfusion imaging, which combined pulse-inversion harmonic (PIH) with pulse-inversion sum-squared-differences (PISSD) threshold-based decision. PIHSSD method just involved simple operations including addition and multiplication and was easy to realize. The sequences of contrast images without logarithmic compression were used to acquire time intensity curves (TICs) from numerous equal-sized regions-of-interest (ROI) covering the entire image plane. Parametric perfusion images were obtained based on the parameters extracted from the TICs, including peak value (PV), area under curve (AUC), mean transit time (MTT), peak value time (PVT), peak width (PW) and climbing rate (CR). Flow phantom was used for validation and the results suggested that PIHSSD method provided 9.6 to 20.3 dB higher contrast-to-tissue ratio (CTR) than PIH method. The results of the experiments of rabbit kidney also showed that the CTR of PIHSSD images was higher than that of PIH images, and the parametric perfusion images based on PIHSSD method provided more accurate quantification of blood perfusion compared with those based on PIH and PISSD methods. It demonstrated that the parametric perfusion imaging achieved good performance though implemented on low-cost ultrasound platform. (E-mail: mxwan@mail.xjtu.edu.cn).

  14. Renal disposition of colistin in the isolated perfused rat kidney.

    PubMed

    Ma, Zheng; Wang, Jiping; Nation, Roger L; Li, Jian; Turnidge, John D; Coulthard, Kingsley; Milne, Robert W

    2009-07-01

    Nephrotoxicity is an important limitation to the clinical use of colistin against Pseudomonas aeruginosa and other gram-negative pathogens. Previous work reported net tubular reabsorption of colistin by the kidney in vivo, but there is no knowledge of its disposition within the kidney. This study investigated the renal disposition and potential transport mechanisms of colistin in the isolated perfused rat kidney (IPK) model by perfusing with colistin sulfate alone (2 microg/ml) or in the presence of potential inhibitors (tetraethylammonium [TEA], glycine-glycine [Gly-Gly], or hydrochloric acid [HCl]) at three different concentrations. When perfused alone, the renal clearances (CL(R)) for colistin A and B (the major components of colistin) in control kidneys were constant and low (mean values < 0.05 ml/min throughout the perfusion). The mean clearance ratios [CR, defined as CL(R)/(f(u) x GFR), where f(u) is the fraction of drug unbound in perfusate and GFR is the glomerular filtration rate] were significantly less than 1. It was concluded that there is net tubular reabsorption of colistin, and this exceeded the reabsorption of water. Less than 10% eliminated from perfusate was recovered in urine, suggesting considerable renal accumulation of colistin. The CR values for colistin were significantly increased when perfused with TEA (500 microM), Gly-Gly (833 microM), and HCl (2,500, 5,000, and 10,000 microM). It is proposed that renal reabsorption of colistin may involve organic cation transporters (inhibited by TEA) and peptide transporters (inhibited by Gly-Gly) and that the process is sensitive to the pH of urine.

  15. Cryogenic, Absolute, High Pressure Sensor

    NASA Technical Reports Server (NTRS)

    Chapman, John J. (Inventor); Shams. Qamar A. (Inventor); Powers, William T. (Inventor)

    2001-01-01

    A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

  16. Complete inhibition of creatine kinase in isolated perfused rat hearts

    SciTech Connect

    Fossel, E.T.; Hoefeler, H.

    1987-01-01

    Transient exposure of an isolated isovolumic perfused rat heart to low concentrations (0.5 mM) of perfusate-born iodoacetamide resulted in complete inhibition of creatine kinase and partial inhibition of glyceraldehyde-3-phosphate dehydrogenase in the heart. At low levels of developed pressure, hearts maintained mechanical function, ATP, and creatine phosphate levels at control values. However, iodoacetamide-inhibited hearts were unable to maintain control values of end diastolic pressure or peak systolic pressure as work load increased. Global ischemia resulted in loss of all ATP without loss of creatine phosphate, indicating lack of active creatine kinase. These results indicate that isovolumic perfused rat hearts are able to maintain normal function and normal levels of high-energy phosphates without active creatine kinase at low levels of developed pressure. /sup 31/P-NMR of the heart was carried out.

  17. Absolute Radiation Thermometry in the NIR

    NASA Astrophysics Data System (ADS)

    Bünger, L.; Taubert, R. D.; Gutschwager, B.; Anhalt, K.; Briaudeau, S.; Sadli, M.

    2017-04-01

    A near infrared (NIR) radiation thermometer (RT) for temperature measurements in the range from 773 K up to 1235 K was characterized and calibrated in terms of the "Mise en Pratique for the definition of the Kelvin" (MeP-K) by measuring its absolute spectral radiance responsivity. Using Planck's law of thermal radiation allows the direct measurement of the thermodynamic temperature independently of any ITS-90 fixed-point. To determine the absolute spectral radiance responsivity of the radiation thermometer in the NIR spectral region, an existing PTB monochromator-based calibration setup was upgraded with a supercontinuum laser system (0.45 μm to 2.4 μm) resulting in a significantly improved signal-to-noise ratio. The RT was characterized with respect to its nonlinearity, size-of-source effect, distance effect, and the consistency of its individual temperature measuring ranges. To further improve the calibration setup, a new tool for the aperture alignment and distance measurement was developed. Furthermore, the diffraction correction as well as the impedance correction of the current-to-voltage converter is considered. The calibration scheme and the corresponding uncertainty budget of the absolute spectral responsivity are presented. A relative standard uncertainty of 0.1 % (k=1) for the absolute spectral radiance responsivity was achieved. The absolute radiometric calibration was validated at four temperature values with respect to the ITS-90 via a variable temperature heatpipe blackbody (773 K ...1235 K) and at a gold fixed-point blackbody radiator (1337.33 K).

  18. Measurement of absolute gravity acceleration in Firenze

    NASA Astrophysics Data System (ADS)

    de Angelis, M.; Greco, F.; Pistorio, A.; Poli, N.; Prevedelli, M.; Saccorotti, G.; Sorrentino, F.; Tino, G. M.

    2011-01-01

    This paper reports the results from the accurate measurement of the acceleration of gravity g taken at two separate premises in the Polo Scientifico of the University of Firenze (Italy). In these laboratories, two separate experiments aiming at measuring the Newtonian constant and testing the Newtonian law at short distances are in progress. Both experiments require an independent knowledge on the local value of g. The only available datum, pertaining to the italian zero-order gravity network, was taken more than 20 years ago at a distance of more than 60 km from the study site. Gravity measurements were conducted using an FG5 absolute gravimeter, and accompanied by seismic recordings for evaluating the noise condition at the site. The absolute accelerations of gravity at the two laboratories are (980 492 160.6 ± 4.0) μGal and (980 492 048.3 ± 3.0) μGal for the European Laboratory for Non-Linear Spectroscopy (LENS) and Dipartimento di Fisica e Astronomia, respectively. Other than for the two referenced experiments, the data here presented will serve as a benchmark for any future study requiring an accurate knowledge of the absolute value of the acceleration of gravity in the study region.

  19. Constrained Least Absolute Deviation Neural Networks

    PubMed Central

    Wang, Zhishun; Peterson, Bradley S.

    2008-01-01

    It is well known that least absolute deviation (LAD) criterion or L1-norm used for estimation of parameters is characterized by robustness, i.e., the estimated parameters are totally resistant (insensitive) to large changes in the sampled data. This is an extremely useful feature, especially, when the sampled data are known to be contaminated by occasionally occurring outliers or by spiky noise. In our previous works, we have proposed the least absolute deviation neural network (LADNN) to solve unconstrained LAD problems. The theoretical proofs and numerical simulations have shown that the LADNN is Lyapunov-stable and it can globally converge to the exact solution to a given unconstrained LAD problem. We have also demonstrated its excellent application value in time-delay estimation. More generally, a practical LAD application problem may contain some linear constraints, such as a set of equalities and/or inequalities, which is called constrained LAD problem, whereas the unconstrained LAD can be considered as a special form of the constrained LAD. In this paper, we present a new neural network called constrained least absolute deviation neural network (CLADNN) to solve general constrained LAD problems. Theoretical proofs and numerical simulations demonstrate that the proposed CLADNN is Lyapunov stable and globally converges to the exact solution to a given constrained LAD problem, independent of initial values. The numerical simulations have also illustrated that the proposed CLADNN can be used to robustly estimate parameters for nonlinear curve fitting, which is extensively used in signal and image processing. PMID:18269958

  20. Database applicaton for absolute spectrophotometry

    NASA Astrophysics Data System (ADS)

    Bochkov, Valery V.; Shumko, Sergiy

    2002-12-01

    32-bit database application with multidocument interface for Windows has been developed to calculate absolute energy distributions of observed spectra. The original database contains wavelength calibrated observed spectra which had been already passed through apparatus reductions such as flatfielding, background and apparatus noise subtracting. Absolute energy distributions of observed spectra are defined in unique scale by means of registering them simultaneously with artificial intensity standard. Observations of sequence of spectrophotometric standards are used to define absolute energy of the artificial standard. Observations of spectrophotometric standards are used to define optical extinction in selected moments. FFT algorithm implemented in the application allows performing convolution (deconvolution) spectra with user-defined PSF. The object-oriented interface has been created using facilities of C++ libraries. Client/server model with Windows Socket functionality based on TCP/IP protocol is used to develop the application. It supports Dynamic Data Exchange conversation in server mode and uses Microsoft Exchange communication facilities.

  1. USE OF A PROGRAMMABLE CALCULATOR IN CARDIOPULMONARY PERFUSION.

    PubMed

    Mills, J David; Tallent, Jerome H.

    1978-06-01

    This study describes a hand-held, battery-powered, programmable instrument (Calculator Model SR-52) that can be taken directly into the operating room by cardiopulmonary perfusionists. Three programs are described in detail: 1) Cardiopulmonary perfusion parameters and estimated blood volume; 2) blood gas parameters and saturations, with temperature corrections; and 3) cardiopulmonary oxygen transfer and oxygenator efficiency. This inexpensive calculator allows perfusion personnel to manipulate easily-derived data into values which heretofore have required elaborate nomograms or special slide rules-or were not available within a reasonable computational time.

  2. Blunted temporal activity of microvascular perfusion heterogeneity in metabolic syndrome: a new attractor for peripheral vascular disease?

    PubMed

    Butcher, Joshua T; Goodwill, Adam G; Stanley, Shyla C; Frisbee, Jefferson C

    2013-02-15

    A key clinical outcome for peripheral vascular disease (PVD) in patients is a progressive decay in skeletal muscle performance and its ability to resist fatigue with elevated metabolic demand. We have demonstrated that PVD in obese Zucker rats (OZR) is partially due to increased perfusion distribution heterogeneity at successive microvascular bifurcations within skeletal muscle. As this increased heterogeneity (γ) is longitudinally present in the network, its cumulative impact is a more heterogeneous distribution of perfusion between terminal arterioles than normal, causing greater regional tissue ischemia. To minimize this negative outcome, a likely compensatory mechanism against an increased γ should be an increased temporal switching at arteriolar bifurcations to minimize downstream perfusion deficits. Using in situ cremaster muscle, we determined that temporal activity (the cumulative sum of absolute differences between successive values of γ, taken every 20 s) was lower in OZR than in control animals, and this difference was present in both proximal (1A-2A) and distal (3A-4A) arteriolar bifurcations. Although adrenoreceptor blockade (phentolamine) improved temporal activity in 1A-2A arteriolar bifurcations in OZR, this was without impact in the distal microcirculation, where only interventions against oxidant stress (Tempol) and thromboxane A(2) activity (SQ-29548) were effective. Analysis of the attractor for γ indicated that it was not only elevated in OZR but also exhibited severe reductions in range, suggesting that the ability of the microcirculation to respond to any challenge is highly restricted and may represent the major contributor to the manifestation of poor muscle performance at this age in OZR.

  3. Absolute classification with unsupervised clustering

    NASA Technical Reports Server (NTRS)

    Jeon, Byeungwoo; Landgrebe, D. A.

    1992-01-01

    An absolute classification algorithm is proposed in which the class definition through training samples or otherwise is required only for a particular class of interest. The absolute classification is considered as a problem of unsupervised clustering when one cluster is known initially. The definitions and statistics of the other classes are automatically developed through the weighted unsupervised clustering procedure, which is developed to keep the cluster corresponding to the class of interest from losing its identity as the class of interest. Once all the classes are developed, a conventional relative classifier such as the maximum-likelihood classifier is used in the classification.

  4. Brain perfusion asymmetry in patients with oral somatic delusions.

    PubMed

    Umezaki, Yojiro; Katagiri, Ayano; Watanabe, Motoko; Takenoshita, Miho; Sakuma, Tomomi; Sako, Emi; Sato, Yusuke; Toriihara, Akira; Uezato, Akihito; Shibuya, Hitoshi; Nishikawa, Toru; Motomura, Haruhiko; Toyofuku, Akira

    2013-06-01

    Oral cenesthopathy is a somatic delusion or hallucination involving the oral area and is categorized as a delusional disorder, somatic type. The pathophysiology of this intractable condition remains obscure. In this study, we clarified the pathophysiology of oral cenesthopathy by evaluating regional brain perfusion. We performed single photon emission computed tomography (SPECT) using (99m)Tc-ethylcysteinate dimer in 16 subjects (cenesthopathy:control = 8:8). The SPECT images were visually assessed qualitatively, and quantitative analyses were also performed using a three-dimensional stereotactic region-of-interest template. The visual assessment revealed a right > left perfusion asymmetry in broad areas of the brain among the patients. The quantitative analysis confirmed that the regional cerebral blood flow values on the right side were significantly larger than those on the left side for most areas of the brain in the patients. A comparison of the R/(R + L) ratios in both groups confirmed the significant brain perfusion asymmetry between the two sides in the callosomarginal, precentral, and temporal regions in the patients. Qualitative evaluation of the SPECT images revealed right > left brain perfusion asymmetry in broad regions of the brain. Moreover, the quantitative analyses confirmed the perfusion asymmetry between the two sides in the frontal and temporal areas. Those may provide the key for elucidation of the pathophysiology of oral cenesthopathy.

  5. Monochromator-Based Absolute Calibration of Radiation Thermometers

    NASA Astrophysics Data System (ADS)

    Keawprasert, T.; Anhalt, K.; Taubert, D. R.; Hartmann, J.

    2011-08-01

    A monochromator integrating-sphere-based spectral comparator facility has been developed to calibrate standard radiation thermometers in terms of the absolute spectral radiance responsivity, traceable to the PTB cryogenic radiometer. The absolute responsivity calibration has been improved using a 75 W xenon lamp with a reflective mirror and imaging optics to a relative standard uncertainty at the peak wavelength of approximately 0.17 % ( k = 1). Via a relative measurement of the out-of-band responsivity, the spectral responsivity of radiation thermometers can be fully characterized. To verify the calibration accuracy, the absolutely calibrated radiation thermometer is used to measure Au and Cu freezing-point temperatures and then to compare the obtained results with the values obtained by absolute methods, resulting in T - T 90 values of +52 mK and -50 mK for the gold and copper fixed points, respectively.

  6. Viable neurons with luxury perfusion in hydrocephalus.

    PubMed

    Wong, C Y; Luciano, M G; MacIntyre, W J; Brunken, R C; Hahn, J F; Go, R T

    1997-09-01

    A woman with hydrocephalus due to aqueductal stenosis had functional imaging of cerebral perfusion and metabolism to demonstrate the effects of endoscopic third ventriculostomy--a new form of internal surgical shunting. Technetium-99m-ECD SPECT and 18F-FDG PET showed regional luxury perfusion at the left frontal region. Three months after a successful third ventriculostomy, a repeated imaging of cerebral perfusion and metabolism showed resolution of luxury perfusion and global improvement of both perfusion and metabolism. This concurred with postoperative clinical improvement. The paired imaging of cerebral perfusion and metabolism provides more information than just imaging perfusion or metabolism. Thus, the detection of perfusion and metabolism mismatch may open a new window of opportunity for surgical intervention.

  7. Contrast-enhanced CT- and MRI-based perfusion assessment for pulmonary diseases: basics and clinical applications

    PubMed Central

    Ohno, Yoshiharu; Koyama, Hisanobu; Lee, Ho Yun; Miura, Sachiko; Yoshikawa, Takeshi; Sugimura, Kazuro

    2016-01-01

    Assessment of regional pulmonary perfusion as well as nodule and tumor perfusions in various pulmonary diseases are currently performed by means of nuclear medicine studies requiring radioactive macroaggregates, dual-energy computed tomography (CT), and dynamic first-pass contrast-enhanced perfusion CT techniques and unenhanced and dynamic first-pass contrast enhanced perfusion magnetic resonance imaging (MRI), as well as time-resolved three-dimensional or four-dimensional contrast-enhanced magnetic resonance angiography (MRA). Perfusion scintigraphy, single-photon emission tomography (SPECT) and SPECT fused with CT have been established as clinically available scintigraphic methods; however, they are limited by perfusion information with poor spatial resolution and other shortcomings. Although positron emission tomography with 15O water can measure absolute pulmonary perfusion, it requires a cyclotron for generation of a tracer with an extremely short half-life (2 min), and can only be performed for academic purposes. Therefore, clinicians are concentrating their efforts on the application of CT-based and MRI-based quantitative and qualitative perfusion assessment to various pulmonary diseases. This review article covers 1) the basics of dual-energy CT and dynamic first-pass contrast-enhanced perfusion CT techniques, 2) the basics of time-resolved contrast-enhanced MRA and dynamic first-pass contrast-enhanced perfusion MRI, and 3) clinical applications of contrast-enhanced CT- and MRI-based perfusion assessment for patients with pulmonary nodule, lung cancer, and pulmonary vascular diseases. We believe that these new techniques can be useful in routine clinical practice for not only thoracic oncology patients, but also patients with different pulmonary vascular diseases. PMID:27523813

  8. Absolute transition probabilities of phosphorus.

    NASA Technical Reports Server (NTRS)

    Miller, M. H.; Roig, R. A.; Bengtson, R. D.

    1971-01-01

    Use of a gas-driven shock tube to measure the absolute strengths of 21 P I lines and 126 P II lines (from 3300 to 6900 A). Accuracy for prominent, isolated neutral and ionic lines is estimated to be 28 to 40% and 18 to 30%, respectively. The data and the corresponding theoretical predictions are examined for conformity with the sum rules.-

  9. Relativistic Absolutism in Moral Education.

    ERIC Educational Resources Information Center

    Vogt, W. Paul

    1982-01-01

    Discusses Emile Durkheim's "Moral Education: A Study in the Theory and Application of the Sociology of Education," which holds that morally healthy societies may vary in culture and organization but must possess absolute rules of moral behavior. Compares this moral theory with current theory and practice of American educators. (MJL)

  10. Absolute Standards for Climate Measurements

    NASA Astrophysics Data System (ADS)

    Leckey, J.

    2016-10-01

    In a world of changing climate, political uncertainty, and ever-changing budgets, the benefit of measurements traceable to SI standards increases by the day. To truly resolve climate change trends on a decadal time scale, on-orbit measurements need to be referenced to something that is both absolute and unchanging. One such mission is the Climate Absolute Radiance and Refractivity Observatory (CLARREO) that will measure a variety of climate variables with an unprecedented accuracy to definitively quantify climate change. In the CLARREO mission, we will utilize phase change cells in which a material is melted to calibrate the temperature of a blackbody that can then be observed by a spectrometer. A material's melting point is an unchanging physical constant that, through a series of transfers, can ultimately calibrate a spectrometer on an absolute scale. CLARREO consists of two primary instruments: an infrared (IR) spectrometer and a reflected solar (RS) spectrometer. The mission will contain orbiting radiometers with sufficient accuracy to calibrate other space-based instrumentation and thus transferring the absolute traceability. The status of various mission options will be presented.

  11. Absolute Rate Theories of Epigenetic Stability

    NASA Astrophysics Data System (ADS)

    Walczak, Aleksandra M.; Onuchic, Jose N.; Wolynes, Peter G.

    2006-03-01

    Spontaneous switching events in most characterized genetic switches are rare, resulting in extremely stable epigenetic properties. We show how simple arguments lead to theories of the rate of such events much like the absolute rate theory of chemical reactions corrected by a transmission factor. Both the probability of the rare cellular states that allow epigenetic escape, and the transmission factor, depend on the rates of DNA binding and unbinding events and on the rates of protein synthesis and degradation. Different mechanisms of escape from the stable attractors occur in the nonadiabatic, weakly adiabatic and strictly adiabatic regimes, characterized by the relative values of those input rates.

  12. Absolute rate theories of epigenetic stability

    NASA Astrophysics Data System (ADS)

    Walczak, Aleksandra M.; Onuchic, José N.; Wolynes, Peter G.

    2005-12-01

    Spontaneous switching events in most characterized genetic switches are rare, resulting in extremely stable epigenetic properties. We show how simple arguments lead to theories of the rate of such events much like the absolute rate theory of chemical reactions corrected by a transmission factor. Both the probability of the rare cellular states that allow epigenetic escape and the transmission factor depend on the rates of DNA binding and unbinding events and on the rates of protein synthesis and degradation. Different mechanisms of escape from the stable attractors occur in the nonadiabatic, weakly adiabatic, and strictly adiabatic regimes, characterized by the relative values of those input rates. rate theory | stochastic gene expression | gene switches

  13. Absolute method of measuring magnetic susceptibility

    USGS Publications Warehouse

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  14. Construction and validation of a microprocessor controlled extracorporal circuit in rats for the optimization of isolated limb perfusion.

    PubMed

    Gürtler, Ulrich; Fuchs, Peter; Stangelmayer, Achim; Bernhardt, Günther; Buschauer, Armin; Spruss, Thilo

    2004-12-01

    Although a few experimental approaches to isolated limb perfusion (ILP) are described in the literature, none of these animal models mimics the clinical perfusion techniques adequately to improve the technique of ILP on the basis of valid preclinical data. Therefore, we developed an ILP setup in rats allowing online monitoring of essential perfusion parameters such as temperature (in perfusate, various tissues, and rectum), pH (perfusate), perfusion pressure, and O(2) concentration (in perfusate, tissue), by a tailor-made data acquisition system. This setup permits close supervision of vital parameters during ILP. Various interdependencies, concerning the flow rate and the pressure of perfusate as well as tissue oxygenation were registered. For the measurement of pO(2) values in the perfusate and in different regions of the perfused hind limb, a novel type of microoptode based on quenching of a fluorescent dye was devised. Stable normothermic (37 degrees C) perfusion conditions were maintained at a constant perfusion pressure in the range of 40-60 mm Hg by administration of the spasmo lytic moxaverine (0.5 mg/mL of perfusate as initial dose) at a perfusate flow rate of 0.5 mL/min for 60 min. At the end of an ILP, there were no signs of tissue damage, neither concerning laboratory data (K(+), myoglobin, creatine kinase, lactic dehydrogenase) nor histopathological criteria. The reported ILP model is not only well suited to investigate the effects of hyperthermia but also to assess the efficacy of new antineoplastic approaches, when nude rats, bearing human tumours in the hind limbs, are used.

  15. Perfusion decellularization of whole organs.

    PubMed

    Guyette, Jacques P; Gilpin, Sarah E; Charest, Jonathan M; Tapias, Luis F; Ren, Xi; Ott, Harald C

    2014-01-01

    The native extracellular matrix (ECM) outlines the architecture of organs and tissues. It provides a unique niche of composition and form, which serves as a foundational scaffold that supports organ-specific cell types and enables normal organ function. Here we describe a standard process for pressure-controlled perfusion decellularization of whole organs for generating acellular 3D scaffolds with preserved ECM protein content, architecture and perfusable vascular conduits. By applying antegrade perfusion of detergents and subsequent washes to arterial vasculature at low physiological pressures, successful decellularization of complex organs (i.e., hearts, lungs and kidneys) can be performed. By using appropriate modifications, pressure-controlled perfusion decellularization can be achieved in small-animal experimental models (rat organs, 4-5 d) and scaled to clinically relevant models (porcine and human organs, 12-14 d). Combining the unique structural and biochemical properties of native acellular scaffolds with subsequent recellularization techniques offers a novel platform for organ engineering and regeneration, for experimentation ex vivo and potential clinical application in vivo.

  16. Dopaminergic Therapy Modulates Cortical Perfusion in Parkinson Disease With and Without Dementia According to Arterial Spin Labeled Perfusion Magnetic Resonance Imaging.

    PubMed

    Lin, Wei-Che; Chen, Pei-Chin; Huang, Yung-Cheng; Tsai, Nai-Wen; Chen, Hsiu-Ling; Wang, Hung-Chen; Lin, Tsu-Kung; Chou, Kun-Hsien; Chen, Meng-Hsiang; Chen, Yi-Wen; Lu, Cheng-Hsien

    2016-02-01

    Arterial spin labeling (ASL) magnetic resonance imaging analyses allow for the quantification of altered cerebral blood flow, and provide a novel means of examining the impact of dopaminergic treatments. The authors examined the cerebral perfusion differences among 17 Parkinson disease (PD) patients, 17 PD with dementia (PDD) patients, and 17 healthy controls and used ASL-MRI to assess the effects of dopaminergic therapies on perfusion in the patients. The authors demonstrated progressive widespread cortical hypoperfusion in PD and PDD and robust effects for the dopaminergic therapies. Specifically, dopaminergic medications further decreased frontal lobe and cerebellum perfusion in the PD and PDD groups, respectively. These patterns of hypoperfusion could be related to cognitive dysfunctions and disease severity. Furthermore, desensitization to dopaminergic therapies in terms of cortical perfusion was found as the disease progressed, supporting the concept that long-term therapies are associated with the therapeutic window narrowing. The highly sensitive pharmaceutical response of ASL allows clinicians and researchers to easily and effectively quantify the absolute perfusion status, which might prove helpful for therapeutic planning.

  17. Thallium-201 myocardial perfusion imaging in myocarditis

    SciTech Connect

    Tamaki, N.; Yonekura, Y.; Kadota, K.; Kambara, H.; Torizuka, K.

    1985-08-01

    TI-201 myocardial perfusion imaging was performed in six patients with clinically documented myocarditis. Each case manifested electrocardiographic abnormalities with elevation of serum cardiac enzymes and no significant stenosis of the coronary arteries observed on angiogram. Resting TI-201 images were visually assessed by three observers. Focal perfusion defects were observed in three cases (50%), among which two showed multiple perfusion defects. Emission computed tomography using TI-201 clearly delineated multifocal lesions in the first case. On the other hand, no significant perfusion defects were noted in the remaining three cases. Thus, myocarditis should be considered as one of the disease entities that may produce perfusion defects on TI-201 myocardial imaging.

  18. Repeated Positron Emission Tomography-Computed Tomography and Perfusion-Computed Tomography Imaging in Rectal Cancer: Fluorodeoxyglucose Uptake Corresponds With Tumor Perfusion

    SciTech Connect

    Janssen, Marco H.M.; Aerts, Hugo J.W.L.; Buijsen, Jeroen; Lambin, Philippe; Lammering, Guido; Oellers, Michel C.

    2012-02-01

    Purpose: The purpose of this study was to analyze both the intratumoral fluorodeoxyglucose (FDG) uptake and perfusion within rectal tumors before and after hypofractionated radiotherapy. Methods and Materials: Rectal cancer patients, referred for preoperative hypofractionated radiotherapy (RT), underwent FDG-positron emission tomography (PET)-computed tomography (CT) and perfusion-CT (pCT) imaging before the start of hypofractionated RT and at the day of the last RT fraction. The pCT-images were analyzed using the extended Kety model, quantifying tumor perfusion with the pharmacokinetic parameters K{sup trans}, v{sub e}, and v{sub p}. The mean and maximum FDG uptake based on the standardized uptake value (SUV) and transfer constant (K{sup trans}) within the tumor were correlated. Also, the tumor was subdivided into eight subregions and for each subregion the mean and maximum SUVs and K{sup trans} values were assessed and correlated. Furthermore, the mean FDG uptake in voxels presenting with the lowest 25% of perfusion was compared with the FDG uptake in the voxels with the 25% highest perfusion. Results: The mean and maximum K{sup trans} values were positively correlated with the corresponding SUVs ({rho} = 0.596, p = 0.001 and {rho} = 0.779, p < 0.001). Also, positive correlations were found for K{sup trans} values and SUVs within the subregions (mean, {rho} = 0.413, p < 0.001; and max, {rho} = 0.540, p < 0.001). The mean FDG uptake in the 25% highest-perfused tumor regions was significantly higher compared with the 25% lowest-perfused regions (10.6% {+-} 5.1%, p = 0.017). During hypofractionated radiotherapy, stable mean (p = 0.379) and maximum (p = 0.280) FDG uptake levels were found, whereas the mean (p = 0.040) and maximum (p = 0.003) K{sup trans} values were found to significantly increase. Conclusion: Highly perfused rectal tumors presented with higher FDG-uptake levels compared with relatively low perfused tumors. Also, intratumor regions with a high FDG

  19. Absolute Antenna Calibration at the US National Geodetic Survey

    NASA Astrophysics Data System (ADS)

    Mader, G. L.; Bilich, A. L.

    2012-12-01

    Geodetic GNSS applications routinely demand millimeter precision and extremely high levels of accuracy. To achieve these accuracies, measurement and instrument biases at the centimeter to millimeter level must be understood. One of these biases is the antenna phase center, the apparent point of signal reception for a GNSS antenna. It has been well established that phase center patterns differ between antenna models and manufacturers; additional research suggests that the addition of a radome or the choice of antenna mount can significantly alter those a priori phase center patterns. For the more demanding GNSS positioning applications and especially in cases of mixed-antenna networks, it is all the more important to know antenna phase center variations as a function of both elevation and azimuth in the antenna reference frame and incorporate these models into analysis software. Determination of antenna phase center behavior is known as "antenna calibration". Since 1994, NGS has computed relative antenna calibrations for more than 350 antennas. In recent years, the geodetic community has moved to absolute calibrations - the IGS adopted absolute antenna phase center calibrations in 2006 for use in their orbit and clock products, and NGS's CORS group began using absolute antenna calibration upon the release of the new CORS coordinates in IGS08 epoch 2005.00 and NAD 83(2011,MA11,PA11) epoch 2010.00. Although NGS relative calibrations can be and have been converted to absolute, it is considered best practice to independently measure phase center characteristics in an absolute sense. Consequently, NGS has developed and operates an absolute calibration system. These absolute antenna calibrations accommodate the demand for greater accuracy and for 2-dimensional (elevation and azimuth) parameterization. NGS will continue to provide calibration values via the NGS web site www.ngs.noaa.gov/ANTCAL, and will publish calibrations in the ANTEX format as well as the legacy ANTINFO

  20. Absolute calibration of optical flats

    DOEpatents

    Sommargren, Gary E.

    2005-04-05

    The invention uses the phase shifting diffraction interferometer (PSDI) to provide a true point-by-point measurement of absolute flatness over the surface of optical flats. Beams exiting the fiber optics in a PSDI have perfect spherical wavefronts. The measurement beam is reflected from the optical flat and passed through an auxiliary optic to then be combined with the reference beam on a CCD. The combined beams include phase errors due to both the optic under test and the auxiliary optic. Standard phase extraction algorithms are used to calculate this combined phase error. The optical flat is then removed from the system and the measurement fiber is moved to recombine the two beams. The newly combined beams include only the phase errors due to the auxiliary optic. When the second phase measurement is subtracted from the first phase measurement, the absolute phase error of the optical flat is obtained.

  1. The Absolute Spectrum Polarimeter (ASP)

    NASA Technical Reports Server (NTRS)

    Kogut, A. J.

    2010-01-01

    The Absolute Spectrum Polarimeter (ASP) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from 30 GHz to 5 THz. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much greater than 1O(raised to the power of { -3}) and Compton distortion y < 10 (raised to the power of{-6}). We describe the ASP instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

  2. Physics of negative absolute temperatures

    NASA Astrophysics Data System (ADS)

    Abraham, Eitan; Penrose, Oliver

    2017-01-01

    Negative absolute temperatures were introduced into experimental physics by Purcell and Pound, who successfully applied this concept to nuclear spins; nevertheless, the concept has proved controversial: a recent article aroused considerable interest by its claim, based on a classical entropy formula (the "volume entropy") due to Gibbs, that negative temperatures violated basic principles of statistical thermodynamics. Here we give a thermodynamic analysis that confirms the negative-temperature interpretation of the Purcell-Pound experiments. We also examine the principal arguments that have been advanced against the negative temperature concept; we find that these arguments are not logically compelling, and moreover that the underlying "volume" entropy formula leads to predictions inconsistent with existing experimental results on nuclear spins. We conclude that, despite the counterarguments, negative absolute temperatures make good theoretical sense and did occur in the experiments designed to produce them.

  3. Optomechanics for absolute rotation detection

    NASA Astrophysics Data System (ADS)

    Davuluri, Sankar

    2016-07-01

    In this article, we present an application of optomechanical cavity for the absolute rotation detection. The optomechanical cavity is arranged in a Michelson interferometer in such a way that the classical centrifugal force due to rotation changes the length of the optomechanical cavity. The change in the cavity length induces a shift in the frequency of the cavity mode. The phase shift corresponding to the frequency shift in the cavity mode is measured at the interferometer output to estimate the angular velocity of absolute rotation. We derived an analytic expression to estimate the minimum detectable rotation rate in our scheme for a given optomechanical cavity. Temperature dependence of the rotation detection sensitivity is studied.

  4. Does machine perfusion decrease ischemia reperfusion injury?

    PubMed

    Bon, D; Delpech, P-O; Chatauret, N; Hauet, T; Badet, L; Barrou, B

    2014-06-01

    In 1990's, use of machine perfusion for organ preservation has been abandoned because of improvement of preservation solutions, efficient without perfusion, easy to use and cheaper. Since the last 15 years, a renewed interest for machine perfusion emerged based on studies performed on preclinical model and seems to make consensus in case of expanded criteria donors or deceased after cardiac death donations. We present relevant studies highlighted the efficiency of preservation with hypothermic machine perfusion compared to static cold storage. Machines for organ preservation being in constant evolution, we also summarized recent developments included direct oxygenation of the perfusat. Machine perfusion technology also enables organ reconditioning during the last hours of preservation through a short period of perfusion on hypothermia, subnormothermia or normothermia. We present significant or low advantages for machine perfusion against ischemia reperfusion injuries regarding at least one primary parameter: risk of DFG, organ function or graft survival.

  5. Diagnostic Performance of Resting CT Myocardial Perfusion in Patients With Possible Acute Coronary Syndrome

    PubMed Central

    Branch, Kelley R.; Busey, Janet; Mitsumori, Lee M.; Strote, Jared; Caldwell, James H.; Busch, Joshua H.; Shuman, William P.

    2014-01-01

    OBJECTIVE Coronary CT angiography has high sensitivity, but modest specificity, to detect acute coronary syndrome. We studied whether adding resting CT myocardial perfusion imaging improved the detection of acute coronary syndrome. SUBJECTS AND METHODS Patients with low-to-intermediate cardiac risk presenting with possible acute coronary syndrome received both the standard of care evaluation and a research thoracic 64-MDCT examination. Patients with an obstructive (> 50%) stenosis or a nonevaluable coronary segment on CT were diagnosed with possible acute coronary syndrome. CT perfusion was determined by applying gray and color Hounsfield unit maps to resting CT angiography images. Adjudicated patient diagnoses were based on the standard of care and 3-month follow-up. Patient-level diagnostic performance for acute coronary syndrome was calculated for coronary CT, CT perfusion, and combined techniques. RESULTS A total of 105 patients were enrolled. Of the nine (9%) patients with acute coronary syndrome, all had obstructive CT stenoses but only three had abnormal CT perfusion. CT perfusion was normal in all other patients. To detect acute coronary syndrome, CT angiography had 100% sensitivity, 89% specificity, and a positive predictive value of 45%. For CT perfusion, specificity and positive predictive value were each 100%, and sensitivity was 33%. Combined cardiac CT and CT perfusion had similar specificity but a higher positive predictive value (100%) than did CT angiography. CONCLUSION Resting CT perfusion using CT angiographic images may have high specificity and may improve CT positive predictive value for acute coronary syndrome without added radiation and contrast. However, normal resting CT perfusion cannot exclude acute coronary syndrome. PMID:23617513

  6. Using Flat-Panel Perfusion Imaging to Measure Cerebral Hemodynamics

    PubMed Central

    Lin, Chung-Jung; Guo, Wan-Yuo; Chang, Feng-Chi; Hung, Sheng-Che; Chen, Ko-Kung; Yu, Deuerling-Zheng; Wu, Chun-Hsien Frank; Liou, Jy-Kang Adrian

    2016-01-01

    Abstract Flat-detector CT perfusion (FD-CTP) imaging has demonstrated efficacy in qualitatively accessing the penumbra in acute stroke equivalent to that of magnetic resonance perfusion (MRP). The aim of our study was to evaluate the feasibility of quantifying oligemia in the brain in patients with carotid stenosis. Ten patients with unilateral carotid stenosis of >70% were included. All MRPs and FD-CTPs were performed before stenting. Region-of-interests (ROIs) including middle cerebral artery territory at basal ganglia level on both stenotic and contralateral sides were used for quantitative analysis. Relative time to peak (rTTP) was defined as TTP of the stenotic side divided by TTP of the contralateral side, and so as relative cerebral blood volume (rCBV), relative mean transit time (rMTT), and relative cerebral blood flow (rCBF). Absolute and relative TTP, CBV, MTT, CBF between two modalities were compared. For absolute quantitative analysis, the correlation of TTP was highest (r = 0.56), followed by CBV (r = 0.47), MTT (r = 0.47), and CBF (r = 0.43); for relative quantitative analysis, rCBF was the highest (r = 0.79), followed by rTTP (r = 0.75) and rCBV (r = 0.50). We confirmed that relative quantitative assessment of FD-CTP is feasible in chronic ischemic disease. Absolute quantitative measurements between MRP and FD-CTP only expressed moderate correlations. Optimization of acquisitions and algorithms is warranted to achieve better quantification. PMID:27196456

  7. In vivo absorption spectroscopy for absolute measurement.

    PubMed

    Furukawa, Hiromitsu; Fukuda, Takashi

    2012-10-01

    In in vivo spectroscopy, there are differences between individual subjects in parameters such as tissue scattering and sample concentration. We propose a method that can provide the absolute value of a particular substance concentration, independent of these individual differences. Thus, it is not necessary to use the typical statistical calibration curve, which assumes an average level of scattering and an averaged concentration over individual subjects. This method is expected to greatly reduce the difficulties encountered during in vivo measurements. As an example, for in vivo absorption spectroscopy, the method was applied to the reflectance measurement in retinal vessels to monitor their oxygen saturation levels. This method was then validated by applying it to the tissue phantom under a variety of absorbance values and scattering efficiencies.

  8. The ileal brake--inhibition of jejunal motility after ileal fat perfusion in man.

    PubMed Central

    Spiller, R C; Trotman, I F; Higgins, B E; Ghatei, M A; Grimble, G K; Lee, Y C; Bloom, S R; Misiewicz, J J; Silk, D B

    1984-01-01

    The possibility that malabsorbed fat passing through the human ileum exerts an inhibitory feedback control on jejunal motility has been investigated in 24 normal subjects by perfusing the ileum with a fat containing solution designed to produce ileal luminal fat concentrations similar to those in steatorrhoea (30-40 mg/ml). Mean transit times through a 30 cm saline perfused jejunal segment were measured by a dye dilution technique. Thirty minutes after ileal fat perfusion, mean transit times rose markedly to 18.9 +/- 2.5 minutes from a control value of 7.5 +/- 0.9 minutes (n = 5; p less than 0.05). This was associated with an increase in volume of the perfused segment which rose to 175.1 +/- 22.9 ml (control 97.6 +/- 10.3 ml, n = 5; p less than 0.05). Transit times and segmental volumes had returned towards basal values 90 minutes after completing the fat perfusion. Further studies showed that ileal fat perfusion produced a pronounced inhibition of jejunal pressure wave activity, percentage duration of activity falling from a control level of 40.3 +/- 5.0% to 14.9 +/- 2.8% in the hour after ileal perfusion (p less than 0.01). Ileal fat perfusion was associated with marked rises in plasma enteroglucagon and neurotensin, the peak values (218 +/- 37 and 68 +/- 13.1 pmol/l) being comparable with those observed postprandially in coeliac disease. These observations show the existence in man of an inhibitory intestinal control mechanism, whereby ileal fat perfusion inhibits jejunal motility and delays caudal transit of jejunal contents. PMID:6706215

  9. Non-Invasive Method of Determining Absolute Intracranial Pressure

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Cantrell, John H., Jr. (Inventor); Hargens, Alan E. (Inventor)

    2004-01-01

    A method is presented for determining absolute intracranial pressure (ICP) in a patient. Skull expansion is monitored while changes in ICP are induced. The patient's blood pressure is measured when skull expansion is approximately zero. The measured blood pressure is indicative of a reference ICP value. Subsequently, the method causes a known change in ICP and measured the change in skull expansion associated therewith. The absolute ICP is a function of the reference ICP value, the known change in ICP and its associated change in skull expansion; and a measured change in skull expansion.

  10. Early Support of Intracranial Perfusion

    DTIC Science & Technology

    2013-10-01

    automated real-time vital signs monitoring data” was funded by USAF (MSA); UM PI: Deborah Stein  The project, titled “Noninvasive intracranial pressure ...scoring of cerebral perfusion pressure and intracranial pressure provides a Brain Trauma Index that predicts outcome in patients with severe TBI... intracranial pressure dose index: Dynamic 3-D scoring in the assessment of Traumatic Brain Injury Proceedings of American Association for the Surgery of

  11. Intestinal perfusion monitoring using photoplethysmography

    NASA Astrophysics Data System (ADS)

    Akl, Tony J.; Wilson, Mark A.; Ericson, M. Nance; Coté, Gerard L.

    2013-08-01

    In abdominal trauma patients, monitoring intestinal perfusion and oxygen consumption is essential during the resuscitation period. Photoplethysmography is an optical technique potentially capable of monitoring these changes in real time to provide the medical staff with a timely and quantitative measure of the adequacy of resuscitation. The challenges for using optical techniques in monitoring hemodynamics in intestinal tissue are discussed, and the solutions to these challenges are presented using a combination of Monte Carlo modeling and theoretical analysis of light propagation in tissue. In particular, it is shown that by using visible wavelengths (i.e., 470 and 525 nm), the perfusion signal is enhanced and the background contribution is decreased compared with using traditional near-infrared wavelengths leading to an order of magnitude enhancement in the signal-to-background ratio. It was further shown that, using the visible wavelengths, similar sensitivity to oxygenation changes could be obtained (over 50% compared with that of near-infrared wavelengths). This is mainly due to the increased contrast between tissue and blood in that spectral region and the confinement of the photons to the thickness of the small intestine. Moreover, the modeling results show that the source to detector separation should be limited to roughly 6 mm while using traditional near-infrared light, with a few centimeters source to detector separation leads to poor signal-to-background ratio. Finally, a visible wavelength system is tested in an in vivo porcine study, and the possibility of monitoring intestinal perfusion changes is showed.

  12. Modeling of nanotherapeutics delivery based on tumor perfusion

    NASA Astrophysics Data System (ADS)

    van de Ven, Anne L.; Abdollahi, Behnaz; Martinez, Carlos J.; Burey, Lacey A.; Landis, Melissa D.; Chang, Jenny C.; Ferrari, Mauro; Frieboes, Hermann B.

    2013-05-01

    Heterogeneities in the perfusion of solid tumors prevent optimal delivery of nanotherapeutics. Clinical imaging protocols for obtaining patient-specific data have proven difficult to implement. It is challenging to determine which perfusion features hold greater prognostic value and to relate measurements to vessel structure and function. With the advent of systemically administered nanotherapeutics whose delivery is dependent on overcoming diffusive and convective barriers to transport, such knowledge is increasingly important. We describe a framework for the automated evaluation of vascular perfusion curves measured at the single vessel level. Primary tumor fragments, collected from triple-negative breast cancer patients and grown as xenografts in mice, were injected with fluorescence contrast and monitored using intravital microscopy. The time to arterial peak and venous delay, two features whose probability distributions were measured directly from time-series curves, were analyzed using a fuzzy c-mean supervised classifier in order to rank individual tumors according to their perfusion characteristics. The resulting rankings correlated inversely with experimental nanoparticle accumulation measurements, enabling the modeling of nanotherapeutics delivery without requiring any underlying assumptions about tissue structure or function, or heterogeneities contained therein. With additional calibration, these methodologies may enable the investigation of nanotherapeutics delivery strategies in a variety of tumor models.

  13. Intrahemispheric Perfusion in Chronic Stroke-Induced Aphasia

    PubMed Central

    Walenski, Matthew; Chen, YuFen; Caplan, David; Rapp, Brenda; Grunewald, Kristin; Nunez, Mia; Zinbarg, Richard; Parrish, Todd B.

    2017-01-01

    Stroke-induced alterations in cerebral blood flow (perfusion) may contribute to functional language impairments and recovery in chronic aphasia. Using MRI, we examined perfusion in the right and left hemispheres of 35 aphasic and 16 healthy control participants. Across 76 regions (38 per hemisphere), no significant between-subjects differences were found in the left, whereas blood flow in the right was increased in the aphasic compared to the control participants. Region-of-interest (ROI) analyses showed a varied pattern of hypo- and hyperperfused regions across hemispheres in the aphasic participants; however, there were no significant correlations between perfusion values and language abilities in these regions. These patterns may reflect autoregulatory changes in blood flow following stroke and/or increases in general cognitive effort, rather than maladaptive language processing. We also examined blood flow in perilesional tissue, finding the greatest hypoperfusion close to the lesion (within 0–6 mm), with greater hypoperfusion in this region compared to more distal regions. In addition, hypoperfusion in this region was significantly correlated with language impairment. These findings underscore the need to consider cerebral perfusion as a factor contributing to language deficits in chronic aphasia as well as recovery of language function. PMID:28357141

  14. [Estimation of absolute risk for fracture].

    PubMed

    Fujiwara, Saeko

    2009-03-01

    Osteoporosis treatment aims to prevent fractures and maintain the QOL of the elderly. However, persons at high risk of future fracture cannot be effectively identified on the basis of bone density (BMD) alone, although BMD is used as an diagnostic criterion. Therefore, the WHO recommended that absolute risk for fracture (10-year probability of fracture) for each individual be evaluated and used as an index for intervention threshold. The 10-year probability of fracture is calculated based on age, sex, BMD at the femoral neck (body mass index if BMD is not available), history of previous fractures, parental hip fracture history, smoking, steroid use, rheumatoid arthritis, secondary osteoporosis and alcohol consumption. The WHO has just announced the development of a calculation tool (FRAX: WHO Fracture Risk Assessment Tool) in February this year. Fractures could be prevented more effectively if, based on each country's medical circumstances, an absolute risk value for fracture to determine when to start medical treatment is established and persons at high risk of fracture are identified and treated accordingly.

  15. Standardization of the cumulative absolute velocity

    SciTech Connect

    O'Hara, T.F.; Jacobson, J.P. )

    1991-12-01

    EPRI NP-5930, A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set.

  16. [Prognostic value of absolute monocyte count in chronic lymphocytic leukaemia].

    PubMed

    Szerafin, László; Jakó, János; Riskó, Ferenc

    2015-04-01

    Bevezetés: Az alacsony perifériás lymphocyta- és magas monocytaszám kedvezőtlen prognózisra utal különböző típusú lymphomákban és egyéb daganatos megbetegedésekben. Krónikus lymphoid leukaemiában azonban az abszolút monocytaszám prognosztikus értékéről csak kevés adat ismert. Célkitűzés: A szerzők krónikus lymphoid leukaemiás betegeik diagnóziskor mért abszolút monocytaszámának hatását vizsgálták a kezelésig eltelt időre és a túlélésre. Módszer: 2005. január 1. és 2012. december 31. között diagnosztizált 223 krónikus lymphoid leukaemiás beteg adatait rögzítették. Értékelték a kezelést igénylő betegek arányát, a kezelésig eltelt idő és a túlélés relatív kockázatát, valamint a halálokokat a Rai-stádiumtól függően, a CD38-, ZAP-70-pozitivitásnak és az abszolút monocytaszámnak megfelelően. Eredmények: Rai 0, I., II., III. és IV. stádiumban a betegek 21,1%-a, 57,4%-a, 88,9%-a, 88,9%-a és 100%-a, CD38-, illetve ZAP-70-pozitivitás esetén a betegek 61,9%-a, illetve 60,8%-a, továbbá, ha az abszolút monocytaszámuk <0,25 G/l, 0,25–0,75 G/l és >0,75 G/l volt, akkor a betegek 76,9%-a, 21,2%-a és 66,2%-a szorult kezelésre. A kezelés elkezdéséig tartó medián idő, illetve a túlélés medián ideje a monocytaszámtól függően 19,5, 65 és 35,5 hónap, illetve 41,5, 65 és 49,5 hónap volt. A kezelésmegkezdés szükségességének relatív kockázata, RR = 1,62 (p<0,01) volt a 0,25 G/l alatti vagy 0,75 G/l feletti és a 0,25–0,75 G/l abszolút monocytaszámú betegek összehasonlításakor, míg a túlélésé RR = 2,41 (p<0,01) volt, ha a 0,25 G/l alatti és feletti abszolút monocytaszámú betegeket hasonlították össze. A relatív kockázatok Rai 0 stádiumú betegekben vizsgálva is szignifikánsak maradtak. A fő halálokok alacsony abszolút monocytaszám esetén fertőzések (41,7%) és a krónikus lymphoid leukaemia (58,3%), míg közepes és magas monocytaszámnál elsősorban egyéb daganatok (25,9% és 35,3%) és egyéb kórokok (48,1% és 11,8%) voltak. Következtetések: Az alacsony és a magas abszolút monocytaszámú betegek kezeléséig eltelt időtartam rövidebb, mint a köztes alcsoportba tartozóké. Az alacsony abszolút monocytaszám – a fertőzéses szövődmények és a krónikus lymphoid leukaemia miatt – megnövekedett halálozással társul. Az abszolút monocytaszám Rai 0 stádiumban is többlet prognosztikus információt tud adni. Orv. Hetil., 2015, 156(15), 592–597.

  17. The Preference of Visualization in Teaching and Learning Absolute Value

    ERIC Educational Resources Information Center

    Konyalioglu, Alper Cihan; Aksu, Zeki; Senel, Esma Ozge

    2012-01-01

    Visualization is mostly despised although it complements and--sometimes--guides the analytical process. This study mainly investigates teachers' preferences concerning the use of the visualization method and determines the extent to which they encourage their students to make use of it within the problem-solving process. This study was conducted…

  18. Ultrasound perfusion signal processing for tumor detection

    NASA Astrophysics Data System (ADS)

    Kim, MinWoo; Abbey, Craig K.; Insana, Michael F.

    2016-04-01

    Enhanced blood perfusion in a tissue mass is an indication of neo-vascularity and a sign of a potential malignancy. Ultrasonic pulsed-Doppler imaging is a preferred modality for noninvasive monitoring of blood flow. However, the weak blood echoes and disorganized slow flow make it difficult to detect perfusion using standard methods without the expense and risk of contrast enhancement. Our research measures the efficiency of conventional power-Doppler (PD) methods at discriminating flow states by comparing measurement performance to that of an ideal discriminator. ROC analysis applied to the experimental results shows that power Doppler methods are just 30-50 % efficient at perfusion flows less than 1ml/min, suggesting an opportunity to improve perfusion assessment through signal processing. A new perfusion estimator is proposed by extending the statistical discriminator approach. We show that 2-D perfusion color imaging may be enhanced using this approach.

  19. Accurate absolute GPS positioning through satellite clock error estimation

    NASA Astrophysics Data System (ADS)

    Han, S.-C.; Kwon, J. H.; Jekeli, C.

    2001-05-01

    An algorithm for very accurate absolute positioning through Global Positioning System (GPS) satellite clock estimation has been developed. Using International GPS Service (IGS) precise orbits and measurements, GPS clock errors were estimated at 30-s intervals. Compared to values determined by the Jet Propulsion Laboratory, the agreement was at the level of about 0.1 ns (3 cm). The clock error estimates were then applied to an absolute positioning algorithm in both static and kinematic modes. For the static case, an IGS station was selected and the coordinates were estimated every 30 s. The estimated absolute position coordinates and the known values had a mean difference of up to 18 cm with standard deviation less than 2 cm. For the kinematic case, data obtained every second from a GPS buoy were tested and the result from the absolute positioning was compared to a differential GPS (DGPS) solution. The mean differences between the coordinates estimated by the two methods are less than 40 cm and the standard deviations are less than 25 cm. It was verified that this poorer standard deviation on 1-s position results is due to the clock error interpolation from 30-s estimates with Selective Availability (SA). After SA was turned off, higher-rate clock error estimates (such as 1 s) could be obtained by a simple interpolation with negligible corruption. Therefore, the proposed absolute positioning technique can be used to within a few centimeters' precision at any rate by estimating 30-s satellite clock errors and interpolating them.

  20. 320-row CT renal perfusion imaging in patients with aortic dissection: A preliminary study

    PubMed Central

    Liu, Dongting; Liu, Jiayi; Wen, Zhaoying; Li, Yu; Sun, Zhonghua; Xu, Qin; Fan, Zhanming

    2017-01-01

    Objective To investigate the clinical value of renal perfusion imaging in patients with aortic dissection (AD) using 320-row computed tomography (CT), and to determine the relationship between renal CT perfusion imaging and various factors of aortic dissection. Methods Forty-three patients with AD who underwent 320-row CT renal perfusion before operation were prospectively enrolled in this study. Diagnosis of AD was confirmed by transthoracic echocardiography. Blood flow (BF) of bilateral renal perfusion was measured and analyzed. CT perfusion imaging signs of AD in relation to the type of AD, number of entry tears and the false lumen thrombus were observed and compared. Results The BF values of patients with type A AD were significantly lower than those of patients with type B AD (P = 0.004). No significant difference was found in the BF between different numbers of intimal tears (P = 0.288), but BF values were significantly higher in cases with a false lumen without thrombus and renal arteries arising from the true lumen than in those with thrombus (P = 0.036). The BF values measured between the true lumen, false lumen and overriding groups were different (P = 0.02), with the true lumen group having the highest. Also, the difference in BF values between true lumen and false lumen groups was statistically significant (P = 0.016), while no statistical significance was found in the other two groups (P > 0.05). The larger the size of intimal entry tears, the greater the BF values (P = 0.044). Conclusions This study shows a direct correlation between renal CT perfusion changes and AD, with the size, number of intimal tears, different types of AD, different renal artery origins and false lumen thrombosis, significantly affecting the perfusion values. PMID:28182709

  1. Absolute bioavailability of quinine formulations in Nigeria.

    PubMed

    Babalola, C P; Bolaji, O O; Ogunbona, F A; Ezeomah, E

    2004-09-01

    This study compared the absolute bioavailability of quinine sulphate as capsule and as tablet against the intravenous (i.v.) infusion of the drug in twelve male volunteers. Six of the volunteers received intravenous infusion over 4 h as well as the capsule formulation of the drug in a cross-over manner, while the other six received the tablet formulation. Blood samples were taken at predetermined time intervals and plasma analysed for quinine (QN) using reversed-phase HPLC method. QN was rapidly absorbed after the two oral formulations with average t(max) of 2.67 h for both capsule and tablet. The mean elimination half-life of QN from the i.v. and oral dosage forms varied between 10 and 13.5 hr and were not statistically different (P > 0.05). On the contrary, the maximum plasma concentration (C(max)) and area under the curve (AUC) from capsule were comparable to those from i.v. (P > 0.05), while these values were markedly higher than values from tablet formulation (P < 0.05). The therapeutic QN plasma levels were not achieved with the tablet formulation. The absolute bioavailability (F) were 73% (C.l., 53.3 - 92.4%) and 39 % (C.I., 21.7 - 56.6%) for the capsule and tablet respectively and the difference was significant (P < 0.05). The subtherapeutic levels obtained from the tablet form used in this study may cause treatment failure during malaria and caution should be taken when predictions are made from results obtained from different formulations of QN.

  2. Lyman alpha SMM/UVSP absolute calibration and geocoronal correction

    NASA Technical Reports Server (NTRS)

    Fontenla, Juan M.; Reichmann, Edwin J.

    1987-01-01

    Lyman alpha observations from the Ultraviolet Spectrometer Polarimeter (UVSP) instrument of the Solar Maximum Mission (SMM) spacecraft were analyzed and provide instrumental calibration details. Specific values of the instrument quantum efficiency, Lyman alpha absolute intensity, and correction for geocoronal absorption are presented.

  3. Cosmology with negative absolute temperatures

    NASA Astrophysics Data System (ADS)

    Vieira, J. P. P.; Byrnes, Christian T.; Lewis, Antony

    2016-08-01

    Negative absolute temperatures (NAT) are an exotic thermodynamical consequence of quantum physics which has been known since the 1950's (having been achieved in the lab on a number of occasions). Recently, the work of Braun et al. [1] has rekindled interest in negative temperatures and hinted at a possibility of using NAT systems in the lab as dark energy analogues. This paper goes one step further, looking into the cosmological consequences of the existence of a NAT component in the Universe. NAT-dominated expanding Universes experience a borderline phantom expansion (w < -1) with no Big Rip, and their contracting counterparts are forced to bounce after the energy density becomes sufficiently large. Both scenarios might be used to solve horizon and flatness problems analogously to standard inflation and bouncing cosmologies. We discuss the difficulties in obtaining and ending a NAT-dominated epoch, and possible ways of obtaining density perturbations with an acceptable spectrum.

  4. Quantitative myocardial perfusion measurement using CT perfusion: a validation study in a porcine model of reperfused acute myocardial infarction.

    PubMed

    So, Aaron; Hsieh, Jiang; Li, Jian-Ying; Hadway, Jennifer; Kong, Hua-Fu; Lee, Ting-Yim

    2012-06-01

    We validated a CT perfusion technique with beam hardening (BH) correction for quantitative measurement of myocardial blood flow (MBF). Acute myocardial infarction (AMI) was created in four pigs by occluding the distal LAD for 1 h followed by reperfusion. MBF was measured from dynamic contrast enhanced CT (DCE-CT) scanning of the heart, with correction of cardiac motion and BH, before ischemic insult and on day 7, 10 and 14 post. On day 14 post, radiolabeled microspheres were injected to measure MBF and the results were compared with those measured by CT perfusion. Excised hearts were stained with 2,3,5-triphenyltetrazolium chloride (TTC) to determine the relationship between MBF measured by CT Perfusion and myocardial viability. MBF measured by CT perfusion was strongly correlated with that by microspheres over a wide range of MBF values (R = 0.81, from 25 to 225 ml min(-1) 100 g(-1)). While MBF in the LAD territory decreased significantly from 98.4 ± 2.5 ml min(-1) 100 g(-1) at baseline to 32.2 ± 9.1 ml min(-1) 100 g(-1), P < 0.05 at day 7 and to 49.4 ± 9.3 ml min(-1) 100 g(-1), P < 0.05 at day 14, the decrease in remote myocardium (LCx territory) from baseline (103.9 ± 1.9 ml min(-1) 100 g(-1)) was minimal throughout the study (90.6 ± 5.1 ml min(-1) 100 g(-1) on day 14 post, P > 0.05). TTC staining confirmed incomplete infarction in the LAD territory and no infarction in the LCx territory. Microvascular obstruction in infarcted tissue resulted in no-reflow and hence persistently low MBF in the reperfused LAD territory which contained a mixture of viable and non-viable tissue. CT perfusion measurement of MBF was accurate and correlated well with histology and microspheres measurements.

  5. Absolute photon-flux measurements in the vacuum ultraviolet

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.; Haddad, G. N.

    1974-01-01

    Absolute photon-flux measurements in the vacuum ultraviolet have extended to short wavelengths by use of rare-gas ionization chambers. The technique involves the measurement of the ion current as a function of the gas pressure in the ion chamber. The true value of the ion current, and hence the absolute photon flux, is obtained by extrapolating the ion current to zero gas pressure. Examples are given at 162 and 266 A. The short-wavelength limit is determined only by the sensitivity of the current-measuring apparatus and by present knowledge of the photoionization processes that occur in the rate gases.

  6. Nonexistence of equilibrium states at absolute negative temperatures

    NASA Astrophysics Data System (ADS)

    Romero-Rochín, Víctor

    2013-08-01

    We show that states of macroscopic systems with purported absolute negative temperatures are not stable under small, yet arbitrary, perturbations. We prove the previous statement using the fact that, in equilibrium, the entropy takes its maximum value. We discuss that, while Ramsey theoretical reformulation of the second law for systems with negative temperatures is logically correct, it must be a priori assumed that those states are in thermodynamic equilibrium. Since we argue that those states cannot occur, reversible processes are impossible, and, thus, Ramsey identification of absolute negative temperatures is untenable.

  7. Technical Pitfalls of Signal Truncation in Perfusion MRI of Glioblastoma.

    PubMed

    Wong, Kelvin K; Fung, Steve H; New, Pamela Z; Wong, Stephen T C

    2016-01-01

    Dynamic susceptibility contrast (DSC) perfusion-weighted imaging (PWI) is widely used in clinical settings for the radiological diagnosis of brain tumor. The signal change in brain tissue in gradient echo-based DSC PWI is much higher than in spin echo-based DSC PWI. Due to its exquisite sensitivity, gradient echo-based sequence is the preferred method for imaging of all tumors except those near the base of the skull. However, high sensitivity also comes with a dynamic range problem. It is not unusual for blood volume to increase in gene-mediated cytotoxic immunotherapy-treated glioblastoma patients. The increase of fractional blood volume sometimes saturates the MRI signal during first-pass contrast bolus arrival and presents signal truncation artifacts of various degrees in the tumor when a significant amount of blood exists in the image pixels. It presents a hidden challenge in PWI, as this signal floor can be either close to noise level or just above and can go no lower. This signal truncation in the signal intensity time course is a significant issue that deserves attention in DSC PWI. In this paper, we demonstrate that relative cerebral blood volume and relative cerebral blood flow (rCBF) are underestimated due to signal truncation in DSC perfusion, in glioblastoma patients. We propose the use of second-pass tissue residue function in rCBF calculation using least-absolute-deviation deconvolution to avoid the underestimation problem.

  8. Technical Pitfalls of Signal Truncation in Perfusion MRI of Glioblastoma

    PubMed Central

    Wong, Kelvin K.; Fung, Steve H.; New, Pamela Z.; Wong, Stephen T. C.

    2016-01-01

    Dynamic susceptibility contrast (DSC) perfusion-weighted imaging (PWI) is widely used in clinical settings for the radiological diagnosis of brain tumor. The signal change in brain tissue in gradient echo-based DSC PWI is much higher than in spin echo-based DSC PWI. Due to its exquisite sensitivity, gradient echo-based sequence is the preferred method for imaging of all tumors except those near the base of the skull. However, high sensitivity also comes with a dynamic range problem. It is not unusual for blood volume to increase in gene-mediated cytotoxic immunotherapy-treated glioblastoma patients. The increase of fractional blood volume sometimes saturates the MRI signal during first-pass contrast bolus arrival and presents signal truncation artifacts of various degrees in the tumor when a significant amount of blood exists in the image pixels. It presents a hidden challenge in PWI, as this signal floor can be either close to noise level or just above and can go no lower. This signal truncation in the signal intensity time course is a significant issue that deserves attention in DSC PWI. In this paper, we demonstrate that relative cerebral blood volume and relative cerebral blood flow (rCBF) are underestimated due to signal truncation in DSC perfusion, in glioblastoma patients. We propose the use of second-pass tissue residue function in rCBF calculation using least-absolute-deviation deconvolution to avoid the underestimation problem. PMID:27531989

  9. Technetium myocardial perfusion agents: an introduction

    SciTech Connect

    English, R.J.; Kozlowski, J.; Tumeh, S.S.; Holman, B.L.

    1987-09-01

    This is the third in a series of four Continuing Education articles on developing radiopharmaceuticals. After reading this article, the reader should be able to: 1) understand the basic concepts of myocardial perfusion imaging; and 2) discuss the advantages of the technetium myocardial perfusion complexes over thallium-201.

  10. Luxury perfusion following anterior ischemic optic neuropathy.

    PubMed

    Friedland, S; Winterkorn, J M; Burde, R M

    1996-09-01

    We present five patients who developed luxury perfusion following anterior ischemic optic neuropathy in whom fluorescein angiography was misinterpreted as "capillary hemangioma" or neovascularization of the disc. In each case, the segment of disc hyperemia corresponded to a spared region of visual field. Luxury perfusion represents a reparative autoregulatory reaction to ischemia.

  11. Long term perfusion system supporting adipogenesis

    PubMed Central

    Abbott, Rosalyn D.; Raja, Waseem K.; Wang, Rebecca Y.; Stinson, Jordan A.; Glettig, Dean L.; Burke, Kelly A.; Kaplan, David L.

    2015-01-01

    Adipose tissue engineered models are needed to enhance our understanding of disease mechanisms and for soft tissue regenerative strategies. Perfusion systems generate more physiologically relevant and sustainable adipose tissue models, however adipocytes have unique properties that make culturing them in a perfusion environment challenging. In this paper we describe the methods involved in the development of two perfusion culture systems (2D and 3D) to test their applicability for long term in vitro adipogenic cultures. It was hypothesized that a silk protein biomaterial scaffold would provide a 3D framework, in combination with perfusion flow, to generate a more physiologically relevant sustainable adipose tissue engineered model than 2D cell culture. Consistent with other studies evaluating 2D and 3D culture systems for adipogenesis we found that both systems successfully model adipogensis, however 3D culture systems were more robust, providing the mechanical structure required to contain the large, fragile adipocytes that were lost in 2D perfused culture systems. 3D perfusion also stimulated greater lipogenesis and lipolysis and resulted in decreased secretion of LDH compared to 2D perfusion. Regardless of culture configuration (2D or 3D) greater glycerol was secreted with the increased nutritional supply provided by perfusion of fresh media. These results are promising for adipose tissue engineering applications including long term cultures for studying disease mechanisms and regenerative approaches, where both acute (days to weeks) and chronic (weeks to months) cultivation are critical for useful insight. PMID:25843606

  12. Myocardial perfusion with rubidium-82. III. Theory relating severity of coronary stenosis to perfusion deficit

    SciTech Connect

    Mullani, N.A.

    1984-11-01

    The relation between the quantitative perfusion deficit, as measured by emission computerized tomography, and the severity of coronary artery stenosis is important for the noninvasive clinical evaluation of coronary artery disease in man. Positron emission tomography allows direct noninvasive measurement of myocardial perfusion and quantification of the size of the perfusion defect. Given this important imformation, a mathematical model has been derived to gauge the severity of a coronary stenosis from quantitative perfusion measurements in the normal and poststenotic regions of the heart. The theoretical basis is presented for relating regional myocardial perfusion and regional perfusion resistance to total, coronary blood flow and resistance at normal resting flow and during maximal coronary vasodilation. The concept of perfusion reserve is presented as a clinical measure of the severity of a stenosis.

  13. [Compromized myocardial perfusion in arrhythmias (author's transl)].

    PubMed

    Simon, H; Neumann, G; Felix, R; Hedde, H; Schaede, A; Thurn, P; Winkler, C

    1977-09-15

    In 7 patients with arrhythmias of various origin the myocardial scintigram displayed either a diffuse or circumscript defect of the perfusion. The coronary arteriogram was normal in all patients. The localized defect of the perfusion in 2 patients was in the region of the upper part of the interventricular septum. Both had a left bundle brunch block. A correlation between the perfusion defect and the electrophysiological abnormality seems probable. The perfusion defect in one of the patients is most probably caused by a previous myocarditis followed by fibrous changes. In the other 6 patients the cause for the perfusion defect is not obvious. A history of myocarditis is missing. The presence of "small vessel disease" in those patients has however to be considered. Our results point to the relation between an abnormality of the microcirculation and arrhythmias in younger patients.

  14. Measuring blood delivery to solitary pulmonary nodules using perfusion magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Zheng, Wei; Wang, Zhifeng; Shen, Li; Gao, Ling; Ford, James C.; Makedon, Fillia S.; Pearlman, Justin D.

    2006-03-01

    With perfusion magnetic resonance imaging (pMRI), perfusion describes the amount of blood passing through a block of tissue in a certain period of time. In pMRI, the tissue having more blood passing through will show higher intensity value as more contrast-labeled blood arrives. Perfusion reflects the delivery of essential nutrients to a block of tissue, and is an important parameter for the tissue status. Considering solitary pulmonary nodules (SPN), perfusion differences between malignant and benign nodules have been studied by different techniques. Much effort has been put into its characterization. In this paper, we proposed and implemented extraction of the SPN time intensity profile to measure blood delivery to solitary pulmonary nodules, describing their perfusion effects. In this method, a SPN time intensity profile is created based on intensity values of the solitary pulmonary nodule in lung pMRI images over time. This method has two steps: nodule tracking and profile clustering. Nodule tracking aligns the solitary pulmonary nodule in pMRI images taken at different time points, dealing with nodule movement resulted from breathing and body movement. Profile clustering implements segmentation of the nodule region and extraction of the time intensity profile of a solitary pulmonary nodule. SPN time intensity profiles reflect patterns of blood delivery to solitary pulmonary nodules, giving us a description of perfusion effect and indirect evidence of tumor angiogenesis. Analysis on SPN time intensity profiles will help the diagnosis of malignant nodules for early lung cancer detection.

  15. Establishing ion ratio thresholds based on absolute peak area for absolute protein quantification using protein cleavage isotope dilution mass spectrometry.

    PubMed

    Loziuk, Philip L; Sederoff, Ronald R; Chiang, Vincent L; Muddiman, David C

    2014-11-07

    Quantitative mass spectrometry has become central to the field of proteomics and metabolomics. Selected reaction monitoring is a widely used method for the absolute quantification of proteins and metabolites. This method renders high specificity using several product ions measured simultaneously. With growing interest in quantification of molecular species in complex biological samples, confident identification and quantitation has been of particular concern. A method to confirm purity or contamination of product ion spectra has become necessary for achieving accurate and precise quantification. Ion abundance ratio assessments were introduced to alleviate some of these issues. Ion abundance ratios are based on the consistent relative abundance (RA) of specific product ions with respect to the total abundance of all product ions. To date, no standardized method of implementing ion abundance ratios has been established. Thresholds by which product ion contamination is confirmed vary widely and are often arbitrary. This study sought to establish criteria by which the relative abundance of product ions can be evaluated in an absolute quantification experiment. These findings suggest that evaluation of the absolute ion abundance for any given transition is necessary in order to effectively implement RA thresholds. Overall, the variation of the RA value was observed to be relatively constant beyond an absolute threshold ion abundance. Finally, these RA values were observed to fluctuate significantly over a 3 year period, suggesting that these values should be assessed as close as possible to the time at which data is collected for quantification.

  16. Quantification of brain perfusion with tracers retained by the brain

    SciTech Connect

    Pupi, A.; Bacciottini, L.; De Cristofaro, M.T.R.; Formiconi, A.R.; Castagnoli, A.

    1991-12-31

    Almost a decade ago, tracers, labelled with {sup 123}I and {sup 99m}Tc, that are retained by the brain, started to be used for studies of regional brain perfusion (regional cerebral blood flow, rCBF). To date, these tracers have been used for brain perfusion imaging with SPECT in brain disorders as well as for physiological activation protocols. Only seldom, however, have they been used in protocols that quantitatively measure rCBF. Nevertheless, comparative studies with perfusion reference tracers have repeatedly demonstrated that the brain uptake of these brain-retained tracers is correlated to perfusion, the major determinant of the distribution of these tracers in the brain. The brain kinetics of {sup 99m}Tc HMPAO, which is the tracer most commonly used, was described with a two-compartment tissue model. The theoretical approach, which is, in itself, sufficient for modeling quantitative measurements with {sup 99m}Tc HMPAO, initially suggested the possibility of empirically narrowing the distance between the brain`s regional uptake of the tracer and rCBF with a linearization algorithm which uses the cerebellum as the reference region. The value of this empirical method is hampered by the fact that the cerebellum can be involved in cerebrovascular disease (i.e. cerebellar diaschisis) as well as in several other brain disorders (e.g. anxiety, and dementia of the Alzheimer type). It also was proposed that different reference regions (occipital, whole slice, or whole brain) should be selected in relation to the brain disorder under study. However, this approach does not solve the main problem because it does not equip us with a reliable tool to evaluate rCBF with a high predictive value, and, at the same time, to reduce intersubject variability. The solution would be to measure a quantitative parameter which directly reflects rCBF, such as the unidirectional influx constant of the freely diffusible flow-limited tracers. 45 refs., 3 figs., 1 tab.

  17. Clinical Evaluation of Brain Perfusion SPECT with Brodmann Areas Mapping in Early Diagnosis of Alzheimer's Disease.

    PubMed

    Valotassiou, Varvara; Papatriantafyllou, John; Sifakis, Nikolaos; Tzavara, Chara; Tsougos, Ioannis; Psimadas, Dimitrios; Fezoulidis, Ioannis; Kapsalaki, Eftychia; Hadjigeorgiou, George; Georgoulias, Panagiotis

    2015-01-01

    Early diagnosis of Alzheimer's disease (AD) based on clinical criteria alone may be problematic, while current and future treatments should be administered earlier in order to be more effective. Thus, various disease biomarkers could be used for early detection of AD. We evaluated brain perfusion with 99mTc-HMPAO single photon emission computed tomography (SPECT) and Brodmann areas (BAs) mapping in mild AD using an automated software (NeuroGam) for the semi-quantitative evaluation of perfusion in BAs and the comparison with the software's normal database. We studied 34 consecutive patients with mild AD: 9 men, 25 women, mean age 70.9 ± 8.1 years, mean Mini-Mental State Examination 22.6 ± 2.5. BAs 25L, 25R, 38L, 38R, 28L, 28R, 36L, and 36R had the lower mean perfusion values, while BAs 31L, 31R, 19R, 18L, 18R, 17L, and 17R had the higher mean values. Compared with healthy subjects of the same age, perfusion values in BAs 25L, 25R, 28R, 28L, 36L, and 36R had the greatest deviations from the healthy sample, while the lowest deviations were found in BAs 32L, 32R, 19R, 24L, 17L, 17R, 18L, and 18R. A percentage of ≥94% of patients had perfusion values more than -2SDs below the mean of healthy subjects in BAs 38R, 38L, 36L, 36R, 23L, 23R, 22L, 44L, 28L, 28R, 25L, and 25R. The corresponding proportion was less than 38% for BAs 11L, 19R, 32L, 32R, 18L, 18R, 24L, and 17R. In conclusion, brain SPECT studies with automated perfusion mapping could be useful as an ancillary tool in daily practice, revealing perfusion impairments in early AD.

  18. Diurnal Curve of the Ocular Perfusion Pressure

    PubMed Central

    Moreira, TCA; Bezerra, BSP; Vianello, MP; Corradi, J; Dorairaj, SK; Prata, TS

    2016-01-01

    ABSTRACT Purpose: To describe the diurnal variation of the ocular perfusion pressure (OPP) in normal, suspects and glaucoma patients. Materials and methods: Seventy-nine subjects were enrolled in a prospective study. The diurnal curve of intraocular pressure (IOP) was performed and blood pressure measurements were obtained. Each participant was grouped into one of the following based upon the clinical evaluation of the optic disk, IOP and standard achromatic perimetry (SAP): 18 eyes were classified as normal (normal SAP, normal optic disk evaluation and IOP < 21 mm Hg in two different measurements), 30 eyes as glaucoma suspect (GS) (normal SAP and mean deviation (MD), C/D ration > 0.5 or asymmetry > 0.2 and/or ocular hypertension), 31 eyes as early glaucoma (MD < -6 dB, glaucomatous optic neuropathy and SAP and MDs on SAP. Standard achromatic perimetry was performed with the Octopus 3.1.1 Dynamic 24-2 program. Intraocular pressure and blood pressure measurements were taken at 6 am, 9 am, 12, 3 and 6 pm. The patients stayed in the seated position for 5 minutes prior to blood pressure measurements. Results: The mean IOP values in all groups did not follow any regular pattern. The peak IOP was found to be greater in suspect [18.70 ± 3.31 (mm Hg ± SD)] and glaucoma (18.77 ± 4.30 mm Hg) patients as compared to normal subjects (16.11 ± 2.27 mm Hg). In studying the diurnal variation of the OPP, we found lower values at 3 pm in normals (34.21 ± 2.07 mm Hg), at 9 am in suspects (54.35 ± 3.32 mm Hg) and at 12 pm in glaucoma patients (34.84 ± 1.44 mm Hg). Conclusion: Each group has a specific OPP variation during the day with the most homogeneous group being the suspect one. It is important to keep studying the IOP and OPP variation for increased comprehension of the pathophysiology of glaucomatous optic neuropathy. How to cite this article: Kanadani FN, Moreira TCA, Bezerra BSP, Vianello MP, Corradi J, Dorairaj SK, Prata TS. Diurnal Curve of the Ocular Perfusion

  19. The Mouse Isolated Perfused Kidney Technique.

    PubMed

    Czogalla, Jan; Schweda, Frank; Loffing, Johannes

    2016-11-17

    The mouse isolated perfused kidney (MIPK) is a technique for keeping a mouse kidney under ex vivo conditions perfused and functional for 1 hr. This is a prerequisite for studying the physiology of the isolated organ and for many innovative applications that may be possible in the future, including perfusion decellularization for kidney bioengineering or the administration of anti-rejection or genome-editing drugs in high doses to prime the kidney for transplantation. During the time of the perfusion, the kidney can be manipulated, renal function can be assessed, and various pharmaceuticals administered. After the procedure, the kidney can be transplanted or processed for molecular biology, biochemical analysis, or microscopy. This paper describes the perfusate and the surgical technique needed for the ex vivo perfusion of mouse kidneys. Details of the perfusion apparatus are given and data are presented showing the viability of the kidney's preparation: renal blood flow, vascular resistance, and urine data as functional, transmission electron micrographs of different nephron segments as morphological readouts, and western blots of transport proteins of different nephron segments as molecular readout.

  20. Mathematical Model for Absolute Magnetic Measuring Systems in Industrial Applications

    NASA Astrophysics Data System (ADS)

    Fügenschuh, Armin; Fügenschuh, Marzena; Ludszuweit, Marina; Mojsic, Aleksandar; Sokół, Joanna

    2015-09-01

    Scales for measuring systems are either based on incremental or absolute measuring methods. Incremental scales need to initialize a measurement cycle at a reference point. From there, the position is computed by counting increments of a periodic graduation. Absolute methods do not need reference points, since the position can be read directly from the scale. The positions on the complete scales are encoded using two incremental tracks with different graduation. We present a new method for absolute measuring using only one track for position encoding up to micrometre range. Instead of the common perpendicular magnetic areas, we use a pattern of trapezoidal magnetic areas, to store more complex information. For positioning, we use the magnetic field where every position is characterized by a set of values measured by a hall sensor array. We implement a method for reconstruction of absolute positions from the set of unique measured values. We compare two patterns with respect to uniqueness, accuracy, stability and robustness of positioning. We discuss how stability and robustness are influenced by different errors during the measurement in real applications and how those errors can be compensated.

  1. Machine Perfusion Enhances Hepatocyte Isolation Yields From Ischemic Livers

    PubMed Central

    Izamis, Maria-Louisa; Perk, Sinem; Calhoun, Candice; Uygun, Korkut; Yarmush, Martin L.; Berthiaume, François

    2015-01-01

    Background High-quality human hepatocytes form the basis of drug safety and efficacy tests, cell-based therapies, and bridge-to-transplantation devices. Presently the only supply of cells derives from an inadequate pool of suboptimal disqualified donor livers. Here we evaluated whether machine perfusion could ameliorate ischemic injury that many of these livers experience prior to hepatocyte isolation. Methods Non-heparinized female Lewis rat livers were exposed to an hour of warm ischemia (34°C) and then perfused for 3 hours. Five different perfusion conditions that utilized the cell isolation apparatus were investigated, namely: (1) modified Williams Medium E and (2) Lifor, both with active oxygenation (95%O2/5%CO2), as well as (3) Lifor passively oxygenated with ambient air (21%O2/0.04%CO2), all at ambient temperatures (20±2°C). At hypothermic temperatures (5±1°C) and under passive oxygenation were (4) University of Wisconsin solution (UW) and (5) Vasosol. Negative and positive control groups comprised livers that had ischemia (WI) and livers that did not (Fresh) prior to cell isolation, respectively. Results Fresh livers yielded 32±9 million cells/g liver while an hour of ischemia reduced the cell yield to 1.6±0.6 million cells/g liver. Oxygenated Williams medium E and Lifor recovered yields of 39±11 and 31±2.3 million cells/g liver, respectively. The passively oxygenated groups produced 15±7 (Lifor), 13±7 (Vasosol), and 10±6 (UW) million cells/g liver. Oxygenated Williams Medium E was most effective at sustaining pH values, avoiding the accumulation of lactate, minimizing edematous weight gain and producing bile during perfusion. Conclusions Machine perfusion results in a dramatic increase in cell yields from livers that have had up to an hour of warm ischemia, but perfusate choice significantly impacts the extent of recovery. Oxygenated Williams Medium E at room temperature is superior to Lifor, UW and Vasosol, largely facilitated by its high

  2. Effect of enhanced red blood cell aggregation on blood flow resistance in an isolated-perfused guinea pig heart preparation.

    PubMed

    Yalcin, Ozlem; Meiselman, Herbert J; Armstrong, Jonathan K; Baskurt, Oguz K

    2005-01-01

    The role of red blood cell (RBC) aggregation as a determinant of in vivo blood flow is still unclear. This study was designed to investigate the influence of a well-controlled enhancement of RBC aggregation on blood flow resistance in an isolated-perfused heart preparation. Guinea pig hearts were perfused through a catheter inserted into the root of the aorta using a pressure servo-controlled pump system that maintained perfusion pressures of 30 to 100 mmHg. The hearts were beating at their intrinsic rates and pumping against the perfusion pressure. RBC aggregation was increased by Pluronic (F98) coating of RBC at a concentration 0.025 mg/ml, corresponding to about a 100% increment in RBC aggregation as measured by erythrocyte sedimentation rate. Isolated heart preparations were perfused with 0.40 l/l hematocrit unmodified guinea pig blood and with Pluronic-coated RBC suspensions in autologous plasma. At high perfusion pressures there were no significant differences between the flow resistance values for the two perfusates, with differences in flow resistance only becoming significant at lower perfusion pressures. These results can be interpreted to reflect the shear dependence of RBC aggregation: higher shear forces associated with higher perfusion pressures should have dispersed RBC aggregates resulting in blood flow resistances similar to control values. Experiments repeated in preparations in which the smooth muscle tone was inhibited by pre-treatment with papaverine indicated that significant effects of enhanced RBC aggregation could be detected at higher perfusion pressures, underlining the compensatory role of vasomotor control mechanisms.

  3. Ventilation-perfusion imaging in pulmonary papillomatosis

    SciTech Connect

    Espinola, D.; Rupani, H.; Camargo, E.E.; Wagner, H.N. Jr.

    1981-11-01

    Three children with laryngeal papillomas involving the lungs had serial ventilation-perfusion scintigrams to assess results of therapy designed to reduce the bronchial involvement. Different imaging patterns were observed depending on size, number, and location of lesions. In early parenchymal involvement a ventilation-perfusion mismatch was seen. The initial and follow-up studies correlated well with clinical and radiographic findings. This noninvasive procedure is helpful in evaluating ventilatory and perfusion impairment in these patients as well as their response to treatment.

  4. Cochlear perfusion with a viscous fluid.

    PubMed

    Wang, Yi; Olson, Elizabeth S

    2016-07-01

    The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawn from basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner's membrane (RM), while in cochleae perfused with 0.125% and 0.25% HA RM was torn. Thus, the CAP threshold elevation was likely due to the broken RM, likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed, perhaps due to the presence and

  5. Absolute optical metrology : nanometers to kilometers

    NASA Technical Reports Server (NTRS)

    Dubovitsky, Serge; Lay, O. P.; Peters, R. D.; Liebe, C. C.

    2005-01-01

    We provide and overview of the developments in the field of high-accuracy absolute optical metrology with emphasis on space-based applications. Specific work on the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor is described along with novel applications of the sensor.

  6. ON A SUFFICIENT CONDITION FOR ABSOLUTE CONTINUITY.

    DTIC Science & Technology

    The formulation of a condition which yields absolute continuity when combined with continuity and bounded variation is the problem considered in the...Briefly, the formulation is achieved through a discussion which develops a proof by contradiction of a sufficiently theorem for absolute continuity which uses in its hypothesis the condition of continuity and bounded variation .

  7. Introducing the Mean Absolute Deviation "Effect" Size

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  8. Monolithically integrated absolute frequency comb laser system

    SciTech Connect

    Wanke, Michael C.

    2016-07-12

    Rather than down-convert optical frequencies, a QCL laser system directly generates a THz frequency comb in a compact monolithically integrated chip that can be locked to an absolute frequency without the need of a frequency-comb synthesizer. The monolithic, absolute frequency comb can provide a THz frequency reference and tool for high-resolution broad band spectroscopy.

  9. The Absolute Gravimeter FG5 - Adjustment and Residual Data Evaluation

    NASA Astrophysics Data System (ADS)

    Orlob, M.; Braun, A.; Henton, J.; Courtier, N.; Liard, J.

    2009-05-01

    The most widely used method of direct terrestrial gravity determination is performed by using a ballistic absolute gravimeter. Today, the FG5 (Micro-g LaCoste; Lafayette, CO) is the most common free-fall absolute gravimeter. It uses the Michelson-type interferometer to determine the absolute gravity value with accuracies up to one part- per-billion of g. Furthermore, absolute gravimeter measurements can be used to assist in the validation and interpretation of temporal variations of the global gravity field, e.g. from the GRACE mission. In addition, absolute gravimetry allows for monitoring gravity changes which are caused by subsurface mass redistributions and/or vertical displacements. In this study,adjustment software was developed and applied to the raw data sets of FG5#106 and FG5#236, made available by Natural Resources Canada. Both data sets have been collected at the same time and place which leads to an intercomparison of the instruments performance. The adjustment software was validated against the official FG5 software package developed by Micro-g Lacoste. In order to identify potential environmental or instrument disturbances in the observed time series, a Lomb- Scargle periodogram analysis was employed. The absolute gravimeter FG5 is particularly sensitive to low frequencies between 0-3Hz. Hence, the focus of the analysis is to detect signals in the band of 0-100 Hz. An artificial signal was added to the measurements for demonstration purposes. Both the performance of the adjustment software and the Lomb-Scargle analysis will be discussed.

  10. Blue laser light increases perfusion of a skin flap via release of nitric oxide from hemoglobin.

    PubMed

    Mittermayr, Rainer; Osipov, Anatoly; Piskernik, Christina; Haindl, Susanne; Dungel, Peter; Weber, Carina; Vladimirov, Yuri A; Redl, Heinz; Kozlov, Andrey V

    2007-01-01

    It has recently been shown that nitrosyl complexes of hemoglobin (NO-Hb) are sensitive to low-level blue laser irradiation, suggesting that laser irradiation can facilitate the release of biologically active nitric oxide (NO), which can affect tissue perfusion. The aim of this study was to evaluate the therapeutic value of blue laser irradiation for local tissue perfusion after surgical intervention. Blood was withdrawn from a rat, exposed to NO and infused back to the same rat or used for in vitro experiments. In vitro, an increase of NO-Hb levels (electron paramagnetic resonance spectroscopy) up to 15 microM in rat blood did not result in the release of detectable amounts of NO (NO selective electrode). Blue laser irradiation of NO-Hb in blood caused decomposition of NO-Hb complexes and release of free NO. Systemic infusion of NO-Hb in rats affected neither systemic circulation (mean arterial pressure) nor local tissue perfusion (Doppler blood flow imaging system). In contrast, a clear enhancement of local tissue perfusion was observed in epigastric flap when elevated NO-Hb levels in blood were combined with local He-Cd laser irradiation focused on the left epigastric artery. The enhancement of regional tissue perfusion was not accompanied by any detectable changes in systemic circulation. This study demonstrates that blue laser irradiation improves local tissue perfusion in a controlled manner stimulating NO release from NO-Hb complexes.

  11. MR mapping of temperature and perfusion for hyperthermia therapy

    NASA Astrophysics Data System (ADS)

    Wlodarczyk, Waldemar; Vlad, Julia; Lange, Thomas; Wust, Peter; Felix, Roland

    2001-05-01

    The promising results, recently obtained in phantom experiments employing the MR-based proton resonance frequency (PRF) method as a non-invasive tool for the temperature monitoring of hyperthermia therapy, are not easily reproduced in vivo. One of the reasons is the impact of perfusion changes on the PRF-measured temperature. In our experiments in vivo, heat was supplied on one side of the volunteers knee or pelvis by a rubber hose with circulating warm water (50iC). The PRF method was calibrated by the constant temperature sensitivity of pure water of 0.011 ppm/iC. MR mapping of perfusion changes was based on T2*-weighted tracking of the first-pass kinetics of contrast agent. The hemodynamic parameters of regional blood volume (rBV) and mean transit time (MTT) were extracted by fitting pixel-by-pixel the first- pass kinetics to the gamma-variate model. Special attention was directed to improve a quality of the automatic non-linear fit at low signal-to-noise values. The distributions of PRF- based temperature changes show large areas of apparently high temperature elevations (exceeding 10iC) in regions close to the heat source, and others with just as large temperature decays in more distant regions. Areas of apparently high temperature elevations correlate with areas of blood flow increase and vice versa. In conclusion, the visible heat- induced PRF changes in vivo are primarily perfusion changes, which mask the much smaller true temperature changes.

  12. Inhomogeneity of pulmonary perfusion during sustained microgravity on SLS-1

    NASA Technical Reports Server (NTRS)

    Prisk, G. Kim; Guy, Harold J. B.; Elliott, Ann R.; West, John B.

    1994-01-01

    We studied the effects of gravity on the inhomogeneity of pulmonary perfusion in humans by performing hyperventilation-breath-hold single-breath measurements before, during, and after 9 days of continuous exposure to microgravity during the Spacelab Life Sciences-1 (SLS-1) mission. In microgravity the indicators of inhomogeneity of perfusion, especially the size of cardiogenic oscillations in expired CO2 and the height of phase IV, were markedly reduced. Cardiogenic oscillations were reduced to approximately 60% of their preflight standing size, and the height of phase IV was between 0 and -8% (a terminal fall became a small terminal rise) of the preflight standing value. The terminal change in expired CO2 was nearly abolished in microgravity, indicating more uniformity of blood flow between lung units that close and those that remain open at the end of expiration. A possible explanation of this observation is the disappearance of gravity-dependent topographic inequality of blood flow. The residual cardiogenic oscillations in expired CO2 imply a persisting inhomogeneity of perfusion in the absence of gravity, probably in lung regions that are not within the same acinus.

  13. Effect of fatty acids on physical properties of microsomes from isolated perfused rat liver.

    PubMed

    Schroeder, F; Goh, E H

    1980-04-01

    A computer-centered spectrofluorimeter was used to examine the physicochemical properties of hepatic microsomes and microsomal lipids obtained from isolated rat livers perfused with medium containing palmitate or oleate. The fatty acid composition and degree of unsaturation of the liver microsomal lipids reflected that the fatty acid present in the perfusate. The absorption corrected fluorescence, relative fluorescence efficiency, polarization, and fluorescence anisotropy of several fluorescent probe molecules were measured to determine if their different microenvironments may be altered by the type of fatty acid infused. The probe molecules beta--parinaric acid and 1,6-diphenyl-1,3,5-hexatriene had higher values for each of these parameters when incorporated into microsomes obtained from livers perfused with a medium containing palmitate than with oleate. The same parameters measured for cholesta-5,7,9(11)-trien-3 beta-ol and N-phenyl-1-naphthylamine were not altered. These differences appeared to be primarily due to alterations in microviscosity of the probe microenvironments since the rotational correlation time of 1,6-diphenyl-1,3,5-hexatriene was 25% lower in the microsomes from livers perfused with oleate as compared to livers perfused with palmitate. Thermal discontinuities in Arrhenius plots were noted in the intact microsomes but not in the isolated microsomal lipids with the fluorescence probe molecule beta-parinaric acid. Break points occurred at 10 degrees C and 26 degrees C for microsomes from livers perfused with palmitate and at 12 degrees C and 17 degrees C for microsomes from livers perfused with oleate containing medium. These results suggest that the physicochemical properties of liver microsomes were determined in part by the fatty acid in the perfusate.

  14. Effect of graded hypoxia on retention of technetium-99m-nitroheterocycle in perfused rat heart

    SciTech Connect

    Rumsey, W.L.; Patel, B.; Linder, K.E.

    1995-04-01

    The purpose of this investigation was to determine the effects of graded hypoxia on the retention of a {sup 99m}Tc-labeled nitroimidazole. Rat hearts were perfused retrogradely with Krebs-Henseleit buffer at 37{degrees}C and paced at 5 Hz. After a 20-min stabilization period, coronary flow was maintained at 8 ml/min/g wet wt and the hearts were perfused with media equilibrated with gas mixtures containing 5% CO{sub 2} and various levels of O{sub 2}, from 544 to 29 Torr. Technetium-99m-O(PnAO-1-(2-nitroimidazole)), BMS-181321, was infused for 20 min into a side port of the aortic cannula. Perfusion continued for an additional 40 min to allow for compound clearance. Each decrease of perfusate PO{sub 2} brought about an increase in the retention of BMS-181321, resulting in a good correlation between its retention and perfusate PO{sub 2} (r=0.97). Myocardial oxygen consumption was independent of oxygen delivery when the perfusate oxygen pressure was greater than 350 Torr. Below this value, oxygen consumption declined markedly as influent PO{sub 2}. A good correlation was obtained between retention of the nitroheterocycle and the cytosolic lactate/pyruvate ratio (r=0.98). When glucose was omitted from the perfusate (PO{sub 2}=27 Torr), retention of the nitroheterocycle was increased by about 25% as compared to hearts perfused in the presence of this substrate. These results indicate that myocardial retention of BMS-181321 is coupled to the level of tissue oxygenation and that hypoxic retention may be affected by substrate input. 24 refs., 3 figs., 1 tab.

  15. Diastolic time fraction as a determinant of subendocardial perfusion.

    PubMed

    Fokkema, Dirk S; VanTeeffelen, Jurgen W G E; Dekker, Simone; Vergroesen, Isabelle; Reitsma, Johannes B; Spaan, Jos A E

    2005-05-01

    Diastolic time fraction (DTF) has been recognized as an important determinant for subendocardial perfusion, but microsphere studies in which DTF was the independent variable are practically absent. In 21 anesthetized goats, the left coronary main stem was artificially perfused at controlled pressure. DTF was varied by pacing the heart, vagus stimulation, or administration of dobutamine. Regional coronary flow was measured with fluorescent microspheres under full adenosine dilation. Perfusion pressure (P(c)) was defined as mean coronary arterial pressure minus minimal left ventricular pressure. Regional flow conductances (flow/P(c)) were as follows: for the subendocardium, C(endo) = -0.103 + 0.197 DTF + 0.00074 P(c) (P < 0.001); for the midmyocardium, conductance = -0.048 + 0.126 DTF + 0.00049 P(c) (P < 0.001); and for the subepicardium, C(epi) was not significant. C(endo)-DTF relations demonstrated a finite value for DTF at which flow is zero, implying that, at physiological pressures, systolic subendocardial flow limitation extends into diastole. The DTF corresponding to an equal conductance in subendocardium and subepicardium (DTF1) was inversely related to P(c): DTF1 = 0.78 - 0.003 P(c) (P < 0.01). When heart rate and P(c) were held constant and dobutamine was administered (5 goats), contractility doubled and DTF increased by 39%, resulting in an increase of C(endo) of 40%. It is concluded that 1) DTF is a determinant of subendocardial perfusion, 2) systolic compression exerts a flow-limiting effect into diastole, and 3) corresponding to clinical findings on inducible ischemia we predict that, under hyperemic conditions, C(endo) < C(epi) if P(c) is lower than approximately 75% of a normal aortic pressure and heart rate >80 beats/min.

  16. Evolution of pulmonary perfusion defects demonstrated with contrast-enhanced dynamic MR perfusion imaging.

    PubMed

    Howarth, N R; Beziat, C; Berthezène, Y

    1999-01-01

    Pulmonary perfusion defects can be demonstrated with contrast-enhanced dynamic MR perfusion imaging. We present the case of a patient with a pulmonary artery sarcoma who presented with a post-operative pulmonary embolus and was followed in the post-operative period with dynamic contrast-enhanced MR perfusion imaging. This technique allows rapid imaging of the first passage of contrast material through the lung after bolus injection in a peripheral vein. To our knowledge, this case report is the first to describe the use of this MR technique in showing the evolution of peripheral pulmonary perfusion defects associated with pulmonary emboli.

  17. Absolute versus temporal anomaly and percent of saturation soil moisture spatial variability for six networks worldwide

    NASA Astrophysics Data System (ADS)

    Brocca, L.; Zucco, G.; Mittelbach, H.; Moramarco, T.; Seneviratne, S. I.

    2014-07-01

    The analysis of the spatial-temporal variability of soil moisture can be carried out considering the absolute (original) soil moisture values or relative values, such as the percent of saturation or temporal anomalies. Over large areas, soil moisture data measured at different sites can be characterized by large differences in their minimum, mean, and maximum absolute values, even though in relative terms their temporal patterns are very similar. In these cases, the analysis considering absolute compared with percent of saturation or temporal anomaly soil moisture values can provide very different results with significant consequences for their use in hydrological applications and climate science. In this study, in situ observations from six soil moisture networks in Italy, Spain, France, Switzerland, Australia, and United States are collected and analyzed to investigate the spatial soil moisture variability over large areas (250-150,000 km2). Specifically, the statistical and temporal stability analyses of soil moisture have been carried out for absolute, temporal anomaly, and percent of saturation values (using two different formulations for temporal anomalies). The results highlight that the spatial variability of the soil moisture dynamic (i.e., temporal anomalies) is significantly lower than that of the absolute soil moisture values. The spatial variance of the time-invariant component (temporal mean of each site) is the predominant contribution to the total spatial variance of absolute soil moisture data. Moreover, half of the networks show a minimum in the spatial variability for intermediate conditions when the temporal anomalies are considered, in contrast with the widely recognized behavior of absolute soil moisture data. The analyses with percent saturation data show qualitatively similar results as those for the temporal anomalies because of the applied normalization which reduces spatial variability induced by differences in mean absolute soil moisture

  18. Absolute Gravity Datum in the Age of Cold Atom Gravimeters

    NASA Astrophysics Data System (ADS)

    Childers, V. A.; Eckl, M. C.

    2014-12-01

    The international gravity datum is defined today by the International Gravity Standardization Net of 1971 (IGSN-71). The data supporting this network was measured in the 1950s and 60s using pendulum and spring-based gravimeter ties (plus some new ballistic absolute meters) to replace the prior protocol of referencing all gravity values to the earlier Potsdam value. Since this time, gravimeter technology has advanced significantly with the development and refinement of the FG-5 (the current standard of the industry) and again with the soon-to-be-available cold atom interferometric absolute gravimeters. This latest development is anticipated to provide improvement in the range of two orders of magnitude as compared to the measurement accuracy of technology utilized to develop ISGN-71. In this presentation, we will explore how the IGSN-71 might best be "modernized" given today's requirements and available instruments and resources. The National Geodetic Survey (NGS), along with other relevant US Government agencies, is concerned about establishing gravity control to establish and maintain high order geodetic networks as part of the nation's essential infrastructure. The need to modernize the nation's geodetic infrastructure was highlighted in "Precise Geodetic Infrastructure, National Requirements for a Shared Resource" National Academy of Science, 2010. The NGS mission, as dictated by Congress, is to establish and maintain the National Spatial Reference System, which includes gravity measurements. Absolute gravimeters measure the total gravity field directly and do not involve ties to other measurements. Periodic "intercomparisons" of multiple absolute gravimeters at reference gravity sites are used to constrain the behavior of the instruments to ensure that each would yield reasonably similar measurements of the same location (i.e. yield a sufficiently consistent datum when measured in disparate locales). New atomic interferometric gravimeters promise a significant

  19. Effect of improving spatial or temporal resolution on image quality and quantitative perfusion assessment with k-t SENSE acceleration in first-pass CMR myocardial perfusion imaging.

    PubMed

    Maredia, Neil; Radjenovic, Aleksandra; Kozerke, Sebastian; Larghat, Abdulghani; Greenwood, John P; Plein, Sven

    2010-12-01

    k-t Sensitivity-encoded (k-t SENSE) acceleration has been used to improve spatial resolution, temporal resolution, and slice coverage in first-pass cardiac magnetic resonance myocardial perfusion imaging. This study compares the effect of investing the speed-up afforded by k-t SENSE acceleration in spatial or temporal resolution. Ten healthy volunteers underwent adenosine stress myocardial perfusion imaging using four saturation-recovery gradient echo perfusion sequences: a reference sequence accelerated by sensitivity encoding (SENSE), and three k-t SENSE-accelerated sequences with higher spatial resolution ("k-t High"), shorter acquisition window ("k-t Fast"), or a shared increase in both parameters ("k-t Hybrid") relative to the reference. Dark-rim artifacts and image quality were analyzed. Semiquantitative myocardial perfusion reserve index (MPRI) and Fermi-derived quantitative MPR were also calculated. The k-t Hybrid sequence produced highest image quality scores at rest (P = 0.015). Rim artifact thickness and extent were lowest using k-t High and k-t Hybrid sequences (P < 0.001). There were no significant differences in MPRI and MPR values derived by each sequence. Maximizing spatial resolution by k-t SENSE acceleration produces the greatest reduction in dark rim artifact. There is good agreement between k-t SENSE and standard acquisition methods for semiquantitative and fully quantitative myocardial perfusion analysis.

  20. What is Needed for Absolute Paleointensity?

    NASA Astrophysics Data System (ADS)

    Valet, J. P.

    2015-12-01

    Many alternative approaches to the Thellier and Thellier technique for absolute paleointensity have been proposed during the past twenty years. One reason is the time consuming aspect of the experiments. Another reason is to avoid uncertainties in determinations of the paleofield which are mostly linked to the presence of multidomain grains. Despite great care taken by these new techniques, there is no indication that they always provide the right answer and in fact sometimes fail. We are convinced that the most valid approach remains the original double heating Thellier protocol provided that natural remanence is controlled by pure magnetite with a narrow distribution of small grain sizes, mostly single domains. The presence of titanium, even in small amount generates biases which yield incorrect field values. Single domain grains frequently dominate the magnetization of glass samples, which explains the success of this selective approach. They are also present in volcanic lava flows but much less frequently, and therefore contribute to the low success rate of most experiments. However the loss of at least 70% of the magnetization at very high temperatures prior to the Curie point appears to be an essential prerequisite that increases the success rate to almost 100% and has been validated from historical flows and from recent studies. This requirement can easily be tested by thermal demagnetization while low temperature experiments can document the detection of single domain magnetite using the δFC/δZFC parameter as suggested (Moskowitz et al, 1993) for biogenic magnetite.

  1. Absolute quantitation of protein posttranslational modification isoform.

    PubMed

    Yang, Zhu; Li, Ning

    2015-01-01

    Mass spectrometry has been widely applied in characterization and quantification of proteins from complex biological samples. Because the numbers of absolute amounts of proteins are needed in construction of mathematical models for molecular systems of various biological phenotypes and phenomena, a number of quantitative proteomic methods have been adopted to measure absolute quantities of proteins using mass spectrometry. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) coupled with internal peptide standards, i.e., the stable isotope-coded peptide dilution series, which was originated from the field of analytical chemistry, becomes a widely applied method in absolute quantitative proteomics research. This approach provides more and more absolute protein quantitation results of high confidence. As quantitative study of posttranslational modification (PTM) that modulates the biological activity of proteins is crucial for biological science and each isoform may contribute a unique biological function, degradation, and/or subcellular location, the absolute quantitation of protein PTM isoforms has become more relevant to its biological significance. In order to obtain the absolute cellular amount of a PTM isoform of a protein accurately, impacts of protein fractionation, protein enrichment, and proteolytic digestion yield should be taken into consideration and those effects before differentially stable isotope-coded PTM peptide standards are spiked into sample peptides have to be corrected. Assisted with stable isotope-labeled peptide standards, the absolute quantitation of isoforms of posttranslationally modified protein (AQUIP) method takes all these factors into account and determines the absolute amount of a protein PTM isoform from the absolute amount of the protein of interest and the PTM occupancy at the site of the protein. The absolute amount of the protein of interest is inferred by quantifying both the absolute amounts of a few PTM

  2. Improved exercise myocardial perfusion during lidoflazine therapy

    SciTech Connect

    Shapiro, W.; Narahara, K.A.; Park, J.

    1983-11-01

    Lidoflazine is a synthetic drug with calcium-channel blocking effects. In a study of 6 patients with severe classic angina pectoris, single-blind administration of lidoflazine was associated with improved myocardial perfusion during exercise as determined by thallium-201 stress scintigraphy. These studies demonstrate that lidoflazine therapy is associated with relief of angina, an increased physical work capacity, and improved regional myocardial perfusion during exercise.

  3. Assessment of the intrapulmonary ventilation-perfusion distribution after the Fontan procedure for complex cardiac anomalies: Relation to pulmonary hemodynamics

    SciTech Connect

    Matsushita, T.; Matsuda, H.; Ogawa, M.; Ohno, K.; Sano, T.; Nakano, S.; Shimazaki, Y.; Nakahara, K.; Arisawa, J.; Kozuka, T. )

    1990-03-15

    In 12 patients who underwent the Fontan procedure for complex cardiac anomalies, lung scanning with xenon-133 was performed to assess the intrapulmonary ventilation-perfusion distribution, and comparison was made with a control group. All data were then analyzed in relation to either pre- or postoperative pulmonary hemodynamic data. In ventilation scans, the intrapulmonary distribution in the right lung was almost normal. In perfusion scans, an abnormal increased upper to lower lobe perfusion ratio greater than the normal value found in the control group was noted in seven patients (58.3%). There was a significant correlation (p less than 0.02) between the upper to lower lobe perfusion ratio and postoperative pulmonary vascular resistance. Furthermore, this perfusion ratio correlated inversely with the preoperative (p less than 0.005) and postoperative (p less than 0.02) right pulmonary artery area index, defined as the ratio of cross-sectional area to the normal value. Of five patients with less than 90% arterial oxygen saturation, four showed an abnormal distribution of pulmonary blood flow greater than the normal perfusion ratio. No patient had evidence of a pulmonary arteriovenous fistula by the echocardiographic contrast study. These results suggest that abnormal distribution of pulmonary blood flow to the upper lung segment may develop in patients after the Fontan procedure, and that insufficient size of the pulmonary artery before operation and the consequent postoperative elevation of pulmonary vascular resistance may be responsible for this perfusion abnormality.

  4. Effect of isolated proximal coronary stenotic lesions on distal myocardial perfusion during exercise

    SciTech Connect

    Nichols, A.B.; Buczek, J.A.; Schwann, T.A.; Esser, P.D.; Blood, D.K.

    1988-07-01

    This study tested the hypothesis that the absolute dimension of a coronary stenotic lesion is a more important determinant of its hemodynamic effect on regional myocardial perfusion during exercise than is relative percent stenosis. In 31 patients with an isolated lesion of the left anterior descending coronary artery, regional myocardial perfusion was determined from thallium-201 scans recorded in the left anterior oblique projection after symptom-limited treadmill exercise. Thallium-201 uptake in the distribution of the left anterior descending coronary artery was expressed as a ratio of thallium-201 uptake in the left circumflex artery distribution. Percent area stenosis, minimal cross-sectional area and mean diameter of each stenotic lesion were measured by computer-assisted cinevideodensitometric analysis of projected coronary arteriograms digitized in a 512 X 512 pixel matrix with 256 gray levels. Thallium-201 uptake in the left anterior descending coronary artery distribution, expressed as a ratio, correlated poorly (r = 0.65) with relative percent stenosis, but correlated significantly (r = 0.83; p less than 0.05) with absolute lesion area. For all 16 patients with reduced regional perfusion in the left anterior descending coronary artery distribution during exercise, lesion cross-sectional area was less than 1.8 mm2 (mean 0.9 +/- 0.6); for 13 of the 15 patients with normal distal perfusion, the area of the stenotic lesion was greater than 1.8 mm2 (mean 2.7 +/- 0.7; p less than 0.001). Percent coronary stenosis failed to predict flow-limiting lesions.

  5. Perfusion visualization and analysis for pulmonary embolism

    NASA Astrophysics Data System (ADS)

    Vaz, Michael S.; Kiraly, Atilla P.; Naidich, David P.; Novak, Carol L.

    2005-04-01

    Given the nature of pulmonary embolism (PE), timely and accurate diagnosis is critical. Contrast enhanced high-resolution CT images allow physicians to accurately identify segmental and sub-segmental emboli. However, it is also important to assess the effect of such emboli on the blood flow in the lungs. Expanding upon previous research, we propose a method for 3D visualization of lung perfusion. The proposed method allows users to examine perfusion throughout the entire lung volume at a single glance, with areas of diminished perfusion highlighted so that they are visible independent of the viewing location. This may be particularly valuable for better accuracy in assessing the extent of hemodynamic alterations resulting from pulmonary emboli. The method also facilitates user interaction and may help identify small peripheral sub-segmental emboli otherwise overlooked. 19 patients referred for possible PE were evaluated by CT following the administration of IV contrast media. An experienced thoracic radiologist assessed the 19 datasets with 17 diagnosed as being positive for PE with multiple emboli. Since anomalies in lung perfusion due to PE can alter the distribution of parenchymal densities, we analyzed features collected from histograms of the computed perfusion maps and demonstrate their potential usefulness as a preliminary test to suggest the presence of PE. These histogram features also offer the possibility of distinguishing distinct patterns associated with chronic PE and may even be useful for further characterization of changes in perfusion or overall density resulting from associated conditions such as pneumonia or diffuse lung disease.

  6. A comparative analysis of the dependences of the hemodynamic parameters on changes in ROI's position in perfusion CT scans

    NASA Astrophysics Data System (ADS)

    Choi, Yong-Seok; Cho, Jae-Hwan; Namgung, Jang-Sun; Kim, Hyo-Jin; Yoon, Dae-Young; Lee, Han-Joo

    2013-05-01

    This study performed a comparative analysis of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and mean time-to-peak (TTP) obtained by changing the region of interest's (ROI) anatomical positions, during CT brain perfusion. We acquired axial source images of perfusion CT from 20 patients undergoing CT perfusion exams due to brain trauma. Subsequently, the CBV, CBF, MTT, and TTP values were calculated through data-processing of the perfusion CT images. The color scales for the CBV, CBF, MTT, and TTP maps were obtained using the image data. Anterior cerebral artery (ACA) was taken as the standard ROI for the calculations of the perfusion values. Differences in the hemodynamic average values were compared in a quantitative analysis by placing ROI and the dividing axial images into proximal, middle, and distal segments anatomically. By performing the qualitative analysis using a blind test, we observed changes in the sensory characteristics by using the color scales of the CBV, CBF, and MTT maps in the proximal, middle, and distal segments. According to the qualitative analysis, no differences were found in CBV, CBF, MTT, and TTP values of the proximal, middle, and distal segments and no changes were detected in the color scales of the the CBV, CBF, MTT, and TTP maps in the proximal, middle, and distal segments. We anticipate that the results of the study will useful in assessing brain trauma patients using by perfusion imaging.

  7. Doppler optical coherence tomography to monitor the effect of photodynamic therapy on tissue morphology and perfusion

    NASA Astrophysics Data System (ADS)

    Aalders, Maurice C. G.; Triesscheijn, Martijn L.; Ruevekamp, Marjan; de Bruin, Daniel M.; Baas, Paul; Faber, Dirk J.; Stewart, Fiona A.

    2006-07-01

    We investigated the feasibility of using optical coherence tomography (OCT) for noninvasive real-time visualization of the vascular effects of photodynamic therapy (PDT) in normal and tumor tissue in mice. Perfusion control measurements were initially performed after administrating vaso-active drugs or clamping of the subcutaneous tumors. Subsequent measurements were made on tumor-bearing mice before and after PDT using the photosensitizer meta-tetrahydroxyphenylchlorin (mTHPC). Tumors were illuminated using either a short drug light interval (D-L, 3h), when mTHPC is primarily located in the tumor vasculature or a long D-L interval (48 h), when the drug is distributed throughout the whole tumor. OCT enabled visualization of the different layers of tumor, and overlying skin with a maximal penetration of ≤ 0.5-1 mm. PDT with a short D-L interval resulted in a significant decrease of perfusion in the tumor periphery, to 20% of pre-treatment values at 160 min, whereas perfusion in the skin initially increased by 10% (at 25 min) and subsequently decreased to 60% of pre-treatment values (at 200 min). PDT with a long D-L interval did not induce significant changes in perfusion. The concept of using noninvasive OCT measurements for monitoring early, treatment-related changes in morphology and perfusion may have applications in evaluating effects of anti-angiogenic or antivascular (cancer) therapy.

  8. A 4D CT digital phantom of an individual human brain for perfusion analysis

    PubMed Central

    Brune, Christoph; van Ginneken, Bram; Prokop, Mathias

    2016-01-01

    Brain perfusion is of key importance to assess brain function. Modern CT scanners can acquire perfusion maps of the cerebral parenchyma in vivo at submillimeter resolution. These perfusion maps give insights into the hemodynamics of the cerebral parenchyma and are critical for example for treatment decisions in acute stroke. However, the relations between acquisition parameters, tissue attenuation curves, and perfusion values are still poorly understood and cannot be unraveled by studies involving humans because of ethical concerns. We present a 4D CT digital phantom specific for an individual human brain to analyze these relations in a bottom-up fashion. Validation of the signal and noise components was based on 1,000 phantom simulations of 20 patient imaging data. This framework was applied to quantitatively assess the relation between radiation dose and perfusion values, and to quantify the signal-to-noise ratios of penumbra regions with decreasing sizes in white and gray matter. This is the first 4D CT digital phantom that enables to address clinical questions without having to expose the patient to additional radiation dose. PMID:27917312

  9. Long-term outdoor cultivation by perfusing spent medium for biodiesel production from Chlorella minutissima.

    PubMed

    Oh, Sung Ho; Kwon, Min Chul; Choi, Woon Yong; Seo, Yong Chang; Kim, Ga Bin; Kang, Do Hyung; Lee, Shin Young; Lee, Hyeon Yong

    2010-08-01

    A unique perfusion process was developed to maintain high concentrations of marine alga, Chlorella minutissima. This method is based on recycling cells by continuous feeding with warm spent sea water from nuclear power plants, which has very similar properties as sea water. A temperature of at least 30 degrees C in a 200 L photo-bioreactor was maintained in this system by perfusion of the thermal plume for 80 days in the coldest season. The maximum cell concentration and total lipid content was 8.3 g-dry wt./L and 23.2 %, w/w, respectively, under mixotrophic conditions. Lipid production was found to be due to a partially or non-growth related process, which implies that large amounts of biomass are needed for a high accumulation of lipids within the cells. At perfusion rates greater than 1.5 L/h, the temperature of the medium inside the reactor was around 30 degrees C, which was optimal for cell growth. For this system, a perfusion rate of 2.8 L/h was determined to be optimal for maintaining rapid cell growth and lipid production during outdoor cultivation. It was absolutely necessary to maintain the appropriate perfusion rate so that the medium temperature was optimal for cell growth. In addition, the lipids produced using this process were shown to be feasible for biodiesel production since the lipid composition of C. minutissima grown under these conditions consisted of 17 % (w/w) of C(16) and 47% (w/w) of C(18). The combined results of this study clearly demonstrated that the discharged energy of the thermal plume could be reused to cultivate marine alga by maintaining a relatively constant temperature in an outdoor photo-bioreactor without the need for supplying any extra energy, which could allow for cheap production of biodiesel from waste energy.

  10. A New Gimmick for Assigning Absolute Configuration.

    ERIC Educational Resources Information Center

    Ayorinde, F. O.

    1983-01-01

    A five-step procedure is provided to help students in making the assignment absolute configuration less bothersome. Examples for both single (2-butanol) and multi-chiral carbon (3-chloro-2-butanol) molecules are included. (JN)

  11. Magnifying absolute instruments for optically homogeneous regions

    SciTech Connect

    Tyc, Tomas

    2011-09-15

    We propose a class of magnifying absolute optical instruments with a positive isotropic refractive index. They create magnified stigmatic images, either virtual or real, of optically homogeneous three-dimensional spatial regions within geometrical optics.

  12. The Simplicity Argument and Absolute Morality

    ERIC Educational Resources Information Center

    Mijuskovic, Ben

    1975-01-01

    In this paper the author has maintained that there is a similarity of thought to be found in the writings of Cudworth, Emerson, and Husserl in his investigation of an absolute system of morality. (Author/RK)

  13. GPU-accelerated voxelwise hepatic perfusion quantification.

    PubMed

    Wang, H; Cao, Y

    2012-09-07

    Voxelwise quantification of hepatic perfusion parameters from dynamic contrast enhanced (DCE) imaging greatly contributes to assessment of liver function in response to radiation therapy. However, the efficiency of the estimation of hepatic perfusion parameters voxel-by-voxel in the whole liver using a dual-input single-compartment model requires substantial improvement for routine clinical applications. In this paper, we utilize the parallel computation power of a graphics processing unit (GPU) to accelerate the computation, while maintaining the same accuracy as the conventional method. Using compute unified device architecture-GPU, the hepatic perfusion computations over multiple voxels are run across the GPU blocks concurrently but independently. At each voxel, nonlinear least-squares fitting the time series of the liver DCE data to the compartmental model is distributed to multiple threads in a block, and the computations of different time points are performed simultaneously and synchronically. An efficient fast Fourier transform in a block is also developed for the convolution computation in the model. The GPU computations of the voxel-by-voxel hepatic perfusion images are compared with ones by the CPU using the simulated DCE data and the experimental DCE MR images from patients. The computation speed is improved by 30 times using a NVIDIA Tesla C2050 GPU compared to a 2.67 GHz Intel Xeon CPU processor. To obtain liver perfusion maps with 626 400 voxels in a patient's liver, it takes 0.9 min with the GPU-accelerated voxelwise computation, compared to 110 min with the CPU, while both methods result in perfusion parameters differences less than 10(-6). The method will be useful for generating liver perfusion images in clinical settings.

  14. Quantification of myocardial perfusion based on signal intensity of flow sensitized MRI

    NASA Astrophysics Data System (ADS)

    Abeykoon, Sumeda B.

    maximum percentage deviation is about 5%. Then the SI-method was used in comparison to a delayed enhanced method to qualitatively and quantitatively assess perfusion deficits in an ischemia-reperfusion (IR) mouse model. The infarcted region of the perfusion map is comparable to the hyper intense region of the delayed enhanced image of the IR mouse. The SI method also used to record a chronological comparison of perfusion on delta sarcoglycan null (DSG) mice. Perfusion of DSG and wild-type (WT) mice at ages of 12 weeks and 32 weeks were compared and percentage change of perfusion was estimated. The result shows that in DSG mice perfusion changes considerably. Finally, the SI method was implemented on a 3 Tesla Philip scanner by modifying to data acquisition method. The perfusion obtained in this is consistent with literature values but further adjustment of pulse sequence and modification of numerical solution is needed. The most important benefit of the SI method is that it reduces scan time 30%--40% and lessens motion artifacts of images compared to the T1 method. This study demonstrates that the signal intensity-based ASL method is a robust alternative to the conventional T1-method.

  15. Absolute cross sections of compound nucleus reactions

    NASA Astrophysics Data System (ADS)

    Capurro, O. A.

    1993-11-01

    The program SEEF is a Fortran IV computer code for the extraction of absolute cross sections of compound nucleus reactions. When the evaporation residue is fed by its parents, only cumulative cross sections will be obtained from off-line gamma ray measurements. But, if one has the parent excitation function (experimental or calculated), this code will make it possible to determine absolute cross sections of any exit channel.

  16. Kelvin and the absolute temperature scale

    NASA Astrophysics Data System (ADS)

    Erlichson, Herman

    2001-07-01

    This paper describes the absolute temperature scale of Kelvin (William Thomson). Kelvin found that Carnot's axiom about heat being a conserved quantity had to be abandoned. Nevertheless, he found that Carnot's fundamental work on heat engines was correct. Using the concept of a Carnot engine Kelvin found that Q1/Q2 = T1/T2. Thermometers are not used to obtain absolute temperatures since they are calculated temperatures.

  17. An efficient polyenergetic SART (pSART) reconstruction algorithm for quantitative myocardial CT perfusion

    SciTech Connect

    Lin, Yuan Samei, Ehsan

    2014-02-15

    Purpose: In quantitative myocardial CT perfusion imaging, beam hardening effect due to dense bone and high concentration iodinated contrast agent can result in visible artifacts and inaccurate CT numbers. In this paper, an efficient polyenergetic Simultaneous Algebraic Reconstruction Technique (pSART) was presented to eliminate the beam hardening artifacts and to improve the CT quantitative imaging ability. Methods: Our algorithm made threea priori assumptions: (1) the human body is composed of several base materials (e.g., fat, breast, soft tissue, bone, and iodine); (2) images can be coarsely segmented to two types of regions, i.e., nonbone regions and noniodine regions; and (3) each voxel can be decomposed into a mixture of two most suitable base materials according to its attenuation value and its corresponding region type information. Based on the above assumptions, energy-independent accumulated effective lengths of all base materials can be fast computed in the forward ray-tracing process and be used repeatedly to obtain accurate polyenergetic projections, with which a SART-based equation can correctly update each voxel in the backward projecting process to iteratively reconstruct artifact-free images. This approach effectively reduces the influence of polyenergetic x-ray sources and it further enables monoenergetic images to be reconstructed at any arbitrarily preselected target energies. A series of simulation tests were performed on a size-variable cylindrical phantom and a realistic anthropomorphic thorax phantom. In addition, a phantom experiment was also performed on a clinical CT scanner to further quantitatively validate the proposed algorithm. Results: The simulations with the cylindrical phantom and the anthropomorphic thorax phantom showed that the proposed algorithm completely eliminated beam hardening artifacts and enabled quantitative imaging across different materials, phantom sizes, and spectra, as the absolute relative errors were reduced

  18. Effect of treppe on isovolumic function in the isolated blood-perfused mouse heart.

    PubMed

    Brooks, W W; Apstein, C S

    1996-08-01

    The effects of treppe on left ventricular function in the isolated mouse heart perfused with physiological buffer or with erythrocyte-rich buffer were compared. Left ventricular systolic and diastolic pressures were measured in the isovolumically contracting (balloon in the left ventricle) mouse hearts. Hearts were isolated from 12 adult Swiss-Webster mice and perfused at constant pressure (approximately 85 mmHg) via the aorta. Perfusate consisted of non-recirculating oxygenated Krebs-Henseleit (KH) solution without or with washed cow red blood cells at a hematocrit of 20% (KH-RBC20). The measured ionized calcium concentration of the perfusates were adjusted to 2.2 mmol/l and the temperature held constant at 37 degrees C. Left ventricular systolic pressure, its derivative and diastolic pressures were recorded via a pressure transducer attached to a small latex balloon which was placed in the left ventricle through a left atrial incision. The balloon volume was adjusted to achieve an end-diastolic pressure of 4-8 mmHg. Left ventricular (LV) developed pressure averaged 111 +/- 4 (mean +/- S.E.M.) with KH alone and 108 +/- 4 mmHg with KH-RBC20 while the coronary flows were 3.1 +/- 0.18 and 0.95 +/- 0.15 ml/min respectively. In both KH solution alone and KH-RBC20, developed pressure remained relatively stable from 3 to 5 Hz while +/- dp/dt increased approximately 10% above values observed at 3 Hz. During KH perfusion with increasing stimulation rates, left ventricular pressure and +/- dP/dt, to a lesser extent, decreased while end-diastolic pressure markedly increased at stimulation rates higher than 5 Hz. However, KH-RBC20 perfusion prevented the marked increase in diastolic pressure with increasing stimulation rates (from 5 to 10 Hz). No significant difference in left ventricular developed pressure or +/dP/dt response to treppe were in evidence between groups. These results demonstrate that diastolic function of the isovolumically contracting mouse heart is sensitive

  19. Absolute Photoionization Cross Sections of Two Cyclic Ketones: Cyclopentanone & Cyclohexanone.

    PubMed

    Price, Chelsea; Fathi, Yasmin; Meloni, Giovanni

    2017-02-23

    Absolute photoionization cross sections for cyclopentanone and cyclohexanone, as well as partial ionization cross sections for the dissociative ionized fragments, are presented in this investigation. Experiments are performed via a multiplexed photoionization mass spectrometer utilizing VUV synchrotron radiation supplied by the Advanced Light Source of Lawrence Berkeley National Laboratory. These results allow the quantification of these species that is relevant to investigate the kinetics and combustion reactions of potential biofuels. The CBS-QB3 calculated values for the adiabatic ionization energies agree well with the experimental values and the identification of possible dissociative fragments is discussed for both systems.

  20. Absolute gravity acceleration measurement in atomic sensor laboratories

    NASA Astrophysics Data System (ADS)

    de Angelis, M.; Greco, F.; Pistorio, A.; Poli, N.; Prevedelli, M.; Saccorotti, G.; Sorrentino, F.; Tino, G. M.

    2012-03-01

    This paper reports the results from the accurate measurement of the acceleration of gravity g taken at two separate premises in the Polo Scientifico of the Florence University (Italy). In these laboratories, two separate experiments aiming at measuring the Newtonian constant and testing the measurement of forces with high spatial resolution are in progress. Both experiments require an independent knowledge on the local value of g. Gravity measurements were conducted using an FG5 absolute gravimeter, and accompanied by seismic recordings for evaluating the noise condition at the site. The absolute accelerations of gravity at the two laboratories are ( 980 492 160.6 ± 4.0) μGal and ( 980 492 048.3 ± 3.0) μGal for the European Laboratory for Non-Linear Spectroscopy (LENS) and Dipartimento di Fisica e Astronomia, respectively. Other than for the two referenced experiments, the data here presented will serve as a benchmark for any future study requiring an accurate knowledge of the absolute value of the acceleration of gravity in the study region.

  1. Neon and Oxygen Absolute Abundances in the Solar Corona

    NASA Astrophysics Data System (ADS)

    Landi, E.; Feldman, U.; Doschek, G. A.

    2007-04-01

    In the present work we use the UV spectrum of a solar flare observed with SOHO SUMER to measure the absolute abundance of Ne in the solar atmosphere. The measurement is carried out using the intensity ratio between the allowed 1s2s3S1-1s2p3P2 Ne IX line at 1248.28 Å and the free-free continuum radiation observed close to the Ne IX line. We find a value of the absolute Ne abundance ANe=8.11+/-0.12, in agreement with previous estimates but substantially higher than the very recent estimate by Asplund et al. based on the oxygen photospheric abundance and the Ne/O relative abundance. Considering our measured ANe value, we argue that the absolute oxygen abundance of Asplund et al. is too low by a factor 1.9. This result has important consequences for models of the solar interior based on helioseismology measurements, as well as on the FIP bias determination of the solar upper atmosphere, solar wind, and solar energetic particles.

  2. High-resolution myocardial perfusion mapping in small animals in vivo by spin-labeling gradient-echo imaging.

    PubMed

    Kober, Frank; Iltis, Isabelle; Izquierdo, Marguerite; Desrois, Martine; Ibarrola, Danielle; Cozzone, Patrick J; Bernard, Monique

    2004-01-01

    An ECG and respiration-gated spin-labeling gradient-echo imaging technique is proposed for the quantitative and completely noninvasive measurement and mapping of myocardial perfusion in small animals in vivo. In contrast to snapshot FLASH imaging, the spatial resolution of the perfusion maps is not limited by the heart rate. A significant improvement in image quality is achieved by synchronizing the inversion pulse to the respiration movements of the animals, thereby allowing for spontaneous respiration. High-resolution myocardial perfusion maps (in-plane resolution=234 x 468 microm2) demonstrating the quality of the perfusion measurement were obtained at 4.7 T in a group of seven freely breathing Wistar-Kyoto rats under isoflurane anesthesia. The mean perfusion value (group average +/- SD) was 5.5 +/- 0.7 ml g(-1)min(-1). In four animals, myocardial perfusion was mapped and measured under cardiac dobutamine stress. Perfusion increased to 11.1 +/- 1.9 ml g(-1)min(-1). The proposed method is particularly useful for the study of small rodents at high fields.

  3. The correlation of contrast-enhanced ultrasound and MRI perfusion quantitative analysis in rabbit VX2 liver cancer.

    PubMed

    Xiang, Zhiming; Liang, Qianwen; Liang, Changhong; Zhong, Guimian

    2014-12-01

    Our objective is to explore the value of liver cancer contrast-enhanced ultrasound (CEUS) and MRI perfusion quantitative analysis in liver cancer and the correlation between these two analysis methods. Rabbit VX2 liver cancer model was established in this study. CEUS was applied. Sono Vue was applied in rabbits by ear vein to dynamically observe and record the blood perfusion and changes in the process of VX2 liver cancer and surrounding tissue. MRI perfusion quantitative analysis was used to analyze the mean enhancement time and change law of maximal slope increasing, which were further compared with the pathological examination results. Quantitative indicators of liver cancer CEUS and MRI perfusion quantitative analysis were compared, and the correlation between them was analyzed by correlation analysis. Rabbit VX2 liver cancer model was successfully established. CEUS showed that time-intensity curve of rabbit VX2 liver cancer showed "fast in, fast out" model while MRI perfusion quantitative analysis showed that quantitative parameter MTE of tumor tissue increased and MSI decreased: the difference was statistically significant (P < 0.01). The diagnostic results of CEUS and MRI perfusion quantitative analysis were not significantly different (P > 0.05). However, the quantitative parameter of them were significantly positively correlated (P < 0.05). CEUS and MRI perfusion quantitative analysis can both dynamically monitor the liver cancer lesion and surrounding liver parenchyma, and the quantitative parameters of them are correlated. The combined application of both is of importance in early diagnosis of liver cancer.

  4. Cortical perfusion index: A predictor of acute rejection in transplanted kidneys

    SciTech Connect

    Atkins, H.L.; Oster, Z.H.; Anaise, D.; Wein, S.; Waltzer, W.; Gonder, A.; Cooch, E.; Rapaport, F.T.

    1985-05-01

    The presently available non-invasive methods for the diagnosis of acute rejection crisis (ARC) of renal transplants are not satisfactory. However, the need for such a test is of paramount clinical importance. A prospective study of 74 post-transplantation events in renal allograft recipients was performed. Clinical, surgical exploration and biopsy data were correlated with TC-99m DTPA scintigraphy using the following indices: Global perfusion index (GPI), cortical perfusion index (CPI), medullary perfusion index (MPI), the peak-to-plateau ratio (P/P), iliac artery peak to renal peak time (delta-P) and washout half-time (T1/2). Of the 74 events, 24 were proven to be due to acute rejection crisis (ARC), 13 were of ureteral obstruction, 18 various nephropathies and 19 in stable renal transplant function. The P/P, delta-P and T1/2 were not good predictors of ARC; the sensitivity was 79%, 79% and 80% respectively. The sensitivity of the GPI was 58% and the specificity was 87%. The cortical perfusion index rated better: specificity=84% and sensitivity=87%. However, the best indicator of ARC seemed to be the percent increase in cortical perfusion index over previous values obtained during stable graft function. Thus the sensitivity was found to be 91% and specificity was 96%. The difference between global and cortical perfusion indices reflects shunting of blood for cortex to medulla. This study suggest that the cortical perfusion index (CPI) and the percent increase in CPI can be used to non-invasively diagnose acute renal allograft rejection.

  5. Absolute magnitude calibration using trigonometric parallax - Incomplete, spectroscopic samples

    NASA Technical Reports Server (NTRS)

    Ratnatunga, Kavan U.; Casertano, Stefano

    1991-01-01

    A new numerical algorithm is used to calibrate the absolute magnitude of spectroscopically selected stars from their observed trigonometric parallax. This procedure, based on maximum-likelihood estimation, can retrieve unbiased estimates of the intrinsic absolute magnitude and its dispersion even from incomplete samples suffering from selection biases in apparent magnitude and color. It can also make full use of low accuracy and negative parallaxes and incorporate censorship on reported parallax values. Accurate error estimates are derived for each of the fitted parameters. The algorithm allows an a posteriori check of whether the fitted model gives a good representation of the observations. The procedure is described in general and applied to both real and simulated data.

  6. Absolute concentration measurements inside a jet plume using video digitization

    NASA Astrophysics Data System (ADS)

    Vauquelin, O.

    An experimental system based on digitized video image analysis is used to measure the local value of the concentration inside a plume. Experiments are carried out in a wind-tunnel for a smoke-seeded turbulent jet plume illuminated with a laser beam. Each test is filmed, subsequently video images are digitized and analysed in order to determine the smoke absolute concentration corresponding to each pixel gray level. This non-intrusive measurement technique is first calibrated and different laws connecting gray level to concentration are established. As a first application, concentration measurements are made inside a turbulent jet plume and compared with measurements conducted using a classic gas analysis method. We finally present and discuss the possibilities offered for the measurements of absolute concentration fluctuations.

  7. Absolute measurement of the extreme UV solar flux

    NASA Technical Reports Server (NTRS)

    Carlson, R. W.; Ogawa, H. S.; Judge, D. L.; Phillips, E.

    1984-01-01

    A windowless rare-gas ionization chamber has been developed to measure the absolute value of the solar extreme UV flux in the 50-575-A region. Successful results were obtained on a solar-pointing sounding rocket. The ionization chamber, operated in total absorption, is an inherently stable absolute detector of ionizing UV radiation and was designed to be independent of effects from secondary ionization and gas effusion. The net error of the measurement is + or - 7.3 percent, which is primarily due to residual outgassing in the instrument, other errors such as multiple ionization, photoelectron collection, and extrapolation to the zero atmospheric optical depth being small in comparison. For the day of the flight, Aug. 10, 1982, the solar irradiance (50-575 A), normalized to unit solar distance, was found to be 5.71 + or - 0.42 x 10 to the 10th photons per sq cm sec.

  8. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    SciTech Connect

    Timmins, Rachel; Klein, Ran; Petryk, Julia; Marvin, Brian; Kemp, Robert A. de; Ruddy, Terrence D.; Wells, R. Glenn; Wei, Lihui

    2015-09-15

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.

  9. Osmotic properties of internally perfused barnacle muscle cells. I. Isosmotic conditions.

    PubMed

    Bitner, J B; Peña-Rasgado, C; Ruiz, J; Cardona, J; Rasgado-Flores, H

    2001-07-01

    Barnacle muscle cells regulate their volume when exposed to anisotonic conditions. Due to their large size, these cells can be internally perfused. Interestingly, perfused cells maintain their volume regulatory properties (17,21). Thus, the osmotic properties of barnacle muscle cells can be studied under conditions in which the intracellular and extracellular osmolalities, the membrane potential (V(M)), the cell volume and the intracellular pressure can all be measured simultaneously. In this manuscript we report the effect that various rates of isosmotic (1000 mOsm x kg H2O(-1)) intracellular perfusion have on cell volume, intracellular pressure, intracellular osmolality, V(M), and the apparent sarcolemmal hydraulic water permeability (L'p). Replacement of the cytosol with the perfusate at a perfusion rate of 0.83 microl x min(-1) took 120 min. During this transition period, the cell volume increased from 45.1+/-6.9 microl to 73.7+/-5.8 microl, the intracellular osmolality decreased from 1406+/-133 to 1188+/-64 mOsm x kg H2O(-1), and the intracellular pressure underwent a transient drop of 2.8 cm H2O. After 2.5 hr of continuous perfusion at 0.83 microl min(-1), the above mentioned parameters reached steady values: the L'p was 1.35 x 10(-5) cm x sec(-1) x Osm(-1) x kg H2O(-1); cell volume was 67.2+/-6 microl; the intracellular osmolality was 1052+/-10 mOsm x kg H2O(-1); the intracellular pressure was 5.6+/-0.4 cm H2O; V(M) depolarized slowly at a rate of 0.03 mV x min(-1). Stepwise increases in the rate of perfusion (from 0.83 to 3.18 microl min(-1)) produced reversible increases in the intracellular pressure, L'p and cell volume and decreases in intracellular osmolality. We conclude that intracellular perfusion: i/ produces a transient removal of intracellular osmotically active components; ii/ promotes sarcolemmal water filtration; iii/ induces a laminar flow of perfusate at the center of the cell, and iv/ enables calculations of sarcolemmal L'p values under

  10. Evaluation of anterior mediastinal solid tumors by CT perfusion: a preliminary study

    PubMed Central

    Bakan, Selim; Kandemirli, Sedat Giray; Dikici, Atilla Süleyman; Erşen, Ezel; Yıldırım, Onur; Samancı, Cesur; Batur, Şebnem; Olgun, Deniz Çebi; Kantarcı, Fatih; Akman, Canan

    2017-01-01

    PURPOSE We aimed to assess the role of computed tomography (CT) perfusion in differentiation of thymoma from thymic hyperplasia, lymphoma, thymic carcinoma, and lung cancer invading anterior mediastinum. METHODS In this study, 25 patients with an anterior mediastinal lesion underwent CT perfusion imaging from January 2015 to February 2016. Diagnoses included thymoma (n=7), thymic hyperplasia (n=8), lymphoma (n=4), thymic carcinoma (n=3), and invasive lung cancer (n=3). Lymphoma, thymic carcinoma, and lung cancer were grouped as malignant tumors for statistical analysis. Values for blood flow, blood volume, and permeability surface were measured in CT perfusion. RESULTS Blood flow and blood volume values were higher in thymoma in comparison to thymic hyperplasia; however, the difference was not statistically significant. Blood volume values were significantly higher in thymoma (mean, 11.4 mL/100 mL; range, 5.2–20.2 mL/100 mL) compared with lymphoma (mean, 5.3 mL/100 mL; range, 2.5–7.2 mL/100 mL) (P = 0.023). Blood flow and blood volume values were significantly higher in thymoma compared with non-thymoma malignant tumors (P = 0.025). CONCLUSION CT perfusion is helpful in differentiating thymoma from non-thymoma malignancies including lymphoma, thymic carcinoma, and invasive lung cancer involving the anterior mediastinum. PMID:27924778

  11. Jasminum flexile flower absolute from India--a detailed comparison with three other jasmine absolutes.

    PubMed

    Braun, Norbert A; Kohlenberg, Birgit; Sim, Sherina; Meier, Manfred; Hammerschmidt, Franz-Josef

    2009-09-01

    Jasminum flexile flower absolute from the south of India and the corresponding vacuum headspace (VHS) sample of the absolute were analyzed using GC and GC-MS. Three other commercially available Indian jasmine absolutes from the species: J. sambac, J. officinale subsp. grandiflorum, and J. auriculatum and the respective VHS samples were used for comparison purposes. One hundred and twenty-one compounds were characterized in J. flexile flower absolute, with methyl linolate, benzyl salicylate, benzyl benzoate, (2E,6E)-farnesol, and benzyl acetate as the main constituents. A detailed olfactory evaluation was also performed.

  12. Myocardial perfusion scintigraphy: the evidence

    PubMed Central

    Anagnostopoulos, C.; Cerqueira, M.; Ell, P. J.; Flint, E. J.; Harbinson, M.; Kelion, A. D.; Al-Mohammad, A.; Prvulovich, E. M.; Shaw, L. J.; Tweddel, A. C.

    2003-01-01

    This review summarises the evidence for the role of myocardial perfusion scintigraphy (MPS) in patients with known or suspected coronary artery disease. It is the product of a consensus conference organised by the British Cardiac Society, the British Nuclear Cardiology Society and the British Nuclear Medicine Society and is endorsed by the Royal College of Physicians of London and the Royal College of Radiologists. It was used to inform the UK National Institute of Clinical Excellence in their appraisal of MPS in patients with chest pain and myocardial infarction. MPS is a well-established, non-invasive imaging technique with a large body of evidence to support its effectiveness in the diagnosis and management of angina and myocardial infarction. It is more accurate than the exercise ECG in detecting myocardial ischaemia and it is the single most powerful technique for predicting future coronary events. The high diagnostic accuracy of MPS allows reliable risk stratification and guides the selection of patients for further interventions, such as revascularisation. This in turn allows more appropriate utilisation of resources, with the potential for both improved clinical outcomes and greater cost-effectiveness. Evidence from modelling and observational studies supports the enhanced cost-effectiveness associated with MPS use. In patients presenting with stable or acute chest pain, strategies of investigation involving MPS are more cost-effective than those not using the technique. MPS also has particular advantages over alternative techniques in the management of a number of patient subgroups, including women, the elderly and those with diabetes, and its use will have a favourable impact on cost-effectiveness in these groups. MPS is already an integral part of many clinical guidelines for the investigation and management of angina and myocardial infarction. However, the technique is underutilised in the UK, as judged by the inappropriately long waiting times and by

  13. Partial volume correction of brain perfusion estimates using the inherent signal data of time-resolved arterial spin labeling.

    PubMed

    Ahlgren, André; Wirestam, Ronnie; Petersen, Esben Thade; Ståhlberg, Freddy; Knutsson, Linda

    2014-09-01

    Quantitative perfusion MRI based on arterial spin labeling (ASL) is hampered by partial volume effects (PVEs), arising due to voxel signal cross-contamination between different compartments. To address this issue, several partial volume correction (PVC) methods have been presented. Most previous methods rely on segmentation of a high-resolution T1 -weighted morphological image volume that is coregistered to the low-resolution ASL data, making the result sensitive to errors in the segmentation and coregistration. In this work, we present a methodology for partial volume estimation and correction, using only low-resolution ASL data acquired with the QUASAR sequence. The methodology consists of a T1 -based segmentation method, with no spatial priors, and a modified PVC method based on linear regression. The presented approach thus avoids prior assumptions about the spatial distribution of brain compartments, while also avoiding coregistration between different image volumes. Simulations based on a digital phantom as well as in vivo measurements in 10 volunteers were used to assess the performance of the proposed segmentation approach. The simulation results indicated that QUASAR data can be used for robust partial volume estimation, and this was confirmed by the in vivo experiments. The proposed PVC method yielded probable perfusion maps, comparable to a reference method based on segmentation of a high-resolution morphological scan. Corrected gray matter (GM) perfusion was 47% higher than uncorrected values, suggesting a significant amount of PVEs in the data. Whereas the reference method failed to completely eliminate the dependence of perfusion estimates on the volume fraction, the novel approach produced GM perfusion values independent of GM volume fraction. The intra-subject coefficient of variation of corrected perfusion values was lowest for the proposed PVC method. As shown in this work, low-resolution partial volume estimation in connection with ASL perfusion

  14. Cardiac tissue engineering using perfusion bioreactor systems

    PubMed Central

    Radisic, Milica; Marsano, Anna; Maidhof, Robert; Wang, Yadong; Vunjak-Novakovic, Gordana

    2009-01-01

    This protocol describes tissue engineering of synchronously contractile cardiac constructs by culturing cardiac cell populations on porous scaffolds (in some cases with an array of channels) and bioreactors with perfusion of culture medium (in some cases supplemented with an oxygen carrier). The overall approach is ‘biomimetic’ in nature as it tends to provide in vivo-like oxygen supply to cultured cells and thereby overcome inherent limitations of diffusional transport in conventional culture systems. In order to mimic the capillary network, cells are cultured on channeled elastomer scaffolds that are perfused with culture medium that can contain oxygen carriers. The overall protocol takes 2–4 weeks, including assembly of the perfusion systems, preparation of scaffolds, cell seeding and cultivation, and on-line and end-point assessment methods. This model is well suited for a wide range of cardiac tissue engineering applications, including the use of human stem cells, and high-fidelity models for biological research. PMID:18388955

  15. Persisting perfusion defects after bronchoscopic removal or spontaneous expulsion of aspirated foreign objects.

    PubMed

    Kassner, E G; Solomon, N A; Steiner, P; Rao, M; Klotz, D H

    1976-10-01

    Follow-up lung scans were obtained in 9 children to determine whether perfusion lung scanning could be used to verify completeness of foreign-body removal. In 4 patients, extensive perfusion defects were present 4-19 days after removal of the object. In 1 patient, the area of hypoperfusion was larger than the territory served by a persistently obstructed lobar bronchus. Follow-up lung scans are of limited value for verifying completeness of foreign-body removal and localization of retained fragments.

  16. Universal Cosmic Absolute and Modern Science

    NASA Astrophysics Data System (ADS)

    Kostro, Ludwik

    The official Sciences, especially all natural sciences, respect in their researches the principle of methodic naturalism i.e. they consider all phenomena as entirely natural and therefore in their scientific explanations they do never adduce or cite supernatural entities and forces. The purpose of this paper is to show that Modern Science has its own self-existent, self-acting, and self-sufficient Natural All-in Being or Omni-Being i.e. the entire Nature as a Whole that justifies the scientific methodic naturalism. Since this Natural All-in Being is one and only It should be considered as the own scientifically justified Natural Absolute of Science and should be called, in my opinion, the Universal Cosmic Absolute of Modern Science. It will be also shown that the Universal Cosmic Absolute is ontologically enormously stratified and is in its ultimate i.e. in its most fundamental stratum trans-reistic and trans-personal. It means that in its basic stratum. It is neither a Thing or a Person although It contains in Itself all things and persons with all other sentient and conscious individuals as well, On the turn of the 20th century the Science has begun to look for a theory of everything, for a final theory, for a master theory. In my opinion the natural Universal Cosmic Absolute will constitute in such a theory the radical all penetrating Ultimate Basic Reality and will substitute step by step the traditional supernatural personal Absolute.

  17. Kinetics of reversible-sequestration of leukocytes by the isolated perfused rat lung

    SciTech Connect

    Goliaei, B.

    1980-08-01

    The kinetics and morphology of sequestration and margination of rat leukocytes were studied using an isolated perfused and ventilated rat lung preparation. Whole rat blood, bone marrow suspension, or leukocyte suspensions, were used to perfuse the isolated rat lung. The lung was also perfused with latex particle suspensions and the passage of particles through the lung capillaries was studied. When a leukocyte suspension was perfused through the lung in the single-pass mode, the rate of sequestration decreased as more cells were perfused. In contrast, latex particles of a size comparable to that of leukocytes were totally stopped by the lung. When the leukocyte suspension was recirculated through the lung, cells were rapidly removed from circulation until a steady state was reached, after which no net removal of cells by the lung occurred. These results indicate that leukocytes are reversibly sequestered from circulation. The sequestered cells marginated and attached to the luminal surface of the endothelium of post-capillary venules and veins. A mathematical model was developed based on the assumption that the attachment and detachment of leukocytes to blood vessel walls follows first-order kinetics. The model correctly predicts the following characteristics of the system: (a) the kinetics of the sequestration of leukocytes by the lung; (b) the existence of a steady state when a suspension of leukocytes is recirculated through the lung; and (c) the independence of the fraction of cells remaining in circulation from the starting concentration for all values of starting concentration. (ERB)

  18. Endoscopic ICG perfusion imaging for flap transplants: technical development

    NASA Astrophysics Data System (ADS)

    Stepp, Herbert; Schachenmayr, Hilmar; Ehrhardt, André; Göbel, Werner; Zhorzel, Sven; Betz, Christian Stephan

    2010-02-01

    Objective: Following tumour surgery in the head and neck region, skin flap transplants are usually required to cover the resection area. The purpose of the development was to provide a simple and reliable means to assess whether the transplanted flap is sufficiently perfused. Methods: Fluorescence of intravenously injected Indocyanine green (ICG) was detected with a slightly modified 3-chip CCD camera. Appropriately coated optical filters allow for excitation of ICG with NIR light and detection of NIR ICGfluorescence with the blue channel of the camera. In addition, low intensities of white light can be transmitted to allow for simultaneous display of a remission image in the green and red channels of the camera. Further processing was performed with a LabVIEW program. Results: A satisfactory white light image (red, green and blue display (RGB)) could be calculated from the remission images recorded with the green and red channels of the camera via a look-up table. The look-up table was programmed to provide an optimized blue intensity value for each combination of red and green values. This was generated using a reference image. Implementation of image tracking and intensity measurements in regions of interest (ROIs) in the images is useful to reliably monitor perfusion kinetics of flap and adjacent normal tissue.

  19. In-vivo regional myocardial perfusion measurements in a porcine model by ECG-gated multislice computed tomography

    NASA Astrophysics Data System (ADS)

    Stantz, Keith M.; Liang, Yun; Meyer, Cristopher A.; Teague, Shawn; Stecker, Michael; Hutchins, Gary; McLennan, Gordon; Persohn, Scott

    2003-05-01

    Purpose: To evaluate whether functional multi-slice computed tomography (MSCT) can identify regional areas of normally perfused and ischemic myocardium in a porcine model. Material and Methods: Three out bred pigs, two of which had ameroids surgically implanted to constrict flow within the LAD and LCx coronary arteries, were injected with 25 mL of iopromide (Isovue) at a rate of 5 mL/second via the femoral or jugular vein. Sixty axial scans along the short axis of the heart was acquired on a 16-slice CT scanner (Philips MX8000-IDT) triggered at end-diastole of the cardiac cycle and acquiring an image within 270 msec. A second series of scans were taken after an intravenous injection of a vasodilator, 150 μg/kg/min of adenosine. ROIs were drawn around the myocardial tissue and the resulting time-density curves were used to extract perfusion values. Results: Determination of the myocardial perfusion and fractional blood volume implementing three different perfusion models. A 5-point averaging or 'smoothing' algorithm was employed to effectively filter the data due to its noisy nature. The (preliminary) average perfusion and fractional blood volume values over selected axial slices for the pig without an artificially induced stenosis were measured to be 84 +/- 22 mL/min/100g-tissue and 0.17 +/- 0.04 mL/g-tissue, the former is consistent with PET scan and EBCT results. The pig with a stenosis in the left LAD coronary artery showed a reduced global perfusion value -- 45 mL/min/100g-tissue. Correlations in regional perfusion values relative to the stenosis were weak. During the infusion of adenosine, averaged perfusion values for the three subjects increased by 46 (+/-45) percent, comparable to increases measured with PET. Conclusion: Quantifying global perfusion values using MDCT appear encouraging. Future work will focus resolving the systematic effects from noise due to signal fluctuation from the porcine tachyardia (80-93 BPM) and provide a more robust measurement

  20. The isolated and perfused working heart of the frog, Rana esculenta: an improved preparation.

    PubMed

    Acierno, R; Gattuso, A; Cerra, M C; Pellegrino, D; Agnisola, C; Tota, B

    1994-05-01

    1. An in vitro preparation of the intact heart of the frog Rana esculenta was set up. 2. The isolated heart, perfused at constant pressure, was spontaneously beating and able to generate physiological values of output pressure, cardiac output, ventricle work and power. It showed the typical phenomenon of the "hypodynamic state" after a relatively constant time from the onset of the perfusion. 3. Perfusion with air-saturated saline and 99.5% oxygen-saturated saline did not show significant differences in the recorded parameters. 4. This experimental model represents a useful tool for physiological and pharmacological studies, especially when the direct analysis of the effects of hormones, mediators or drugs requires an intact heart preparation.

  1. Imaging of myocardial perfusion with magnetic resonance.

    PubMed

    Barkhausen, Jörg; Hunold, Peter; Jochims, Markus; Debatin, Jörg F

    2004-06-01

    Coronary artery disease (CAD) is currently the leading cause of death in developed nations. Reflecting the complexity of cardiac function and morphology, noninvasive diagnosis of CAD represents a major challenge for medical imaging. Although coronary artery stenoses can be depicted with magnetic resonance (MR) and computed tomography (CT) techniques, its functional or hemodynamic impact frequently remains elusive. Therefore, there is growing interest in other, target organ-specific parameters such as myocardial function at stress and first-pass myocardial perfusion imaging to assess myocardial blood flow. This review explores the pathophysiologic background, recent technical developments, and current clinical status of first-pass MR imaging (MRI) of myocardial perfusion.

  2. An 'in situ' perfusion system suitable for investigating mammary-tissue metabolism in the lactating rat. Hormonal regulation of acetyl-CoA carboxylase.

    PubMed Central

    Clegg, R A; Calvert, D T

    1988-01-01

    A technique is described for the non-recirculating perfusion of inguinal/abdominal mammary tissue in situ in anaesthetized lactating rats. Tissue viability was maintained, without resort to infusion of vasoactive chemicals which may also be effectors of cellular metabolism, for at least 90 min. Total tissue adenine nucleotides (per mg of DNA) were somewhat decreased in perfused relative to non-perfused mammary tissue. DNA content (per g wet wt. of tissue) was diminished after 90 min of perfusion to approx. 65% of its value in control tissue. Adenylate energy-charge ratios were lower in perfused tissue in the absence of hormones than in control tissue. They were increased to control values by the presence of either insulin or isoprenaline in the perfusate. No changes occurred in flow rate of the perfusate that might account for these increases. In mammary tissue perfused without addition of hormones, acetyl-CoA carboxylase activities were similar to those measured in control tissue samples, although activity-ratio measurements implied some increase in the phosphorylation of this enzyme. Insulin or isoprenaline increased the activity of acetyl-CoA carboxylase, especially when this was measured at low concentrations of citrate. Confirming conclusions from previous experiments with mammary acini and explant preparations, insulin activated acetyl-CoA carboxylase in mammary tissue, but inhibition of its activity was not mediated by cyclic AMP. PMID:2895636

  3. Quantitative standards for absolute linguistic universals.

    PubMed

    Piantadosi, Steven T; Gibson, Edward

    2014-01-01

    Absolute linguistic universals are often justified by cross-linguistic analysis: If all observed languages exhibit a property, the property is taken to be a likely universal, perhaps specified in the cognitive or linguistic systems of language learners and users. In many cases, these patterns are then taken to motivate linguistic theory. Here, we show that cross-linguistic analysis will very rarely be able to statistically justify absolute, inviolable patterns in language. We formalize two statistical methods--frequentist and Bayesian--and show that in both it is possible to find strict linguistic universals, but that the numbers of independent languages necessary to do so is generally unachievable. This suggests that methods other than typological statistics are necessary to establish absolute properties of human language, and thus that many of the purported universals in linguistics have not received sufficient empirical justification.

  4. Absolute Measurements of Radiation Damage in Nanometer Thick Films

    PubMed Central

    Alizadeh, Elahe; Sanche, Léon

    2013-01-01

    We address the problem of absolute measurements of radiation damage in films of nanometer thicknesses. Thin films of DNA (~ 2–160nm) are deposited onto glass substrates and irradiated with varying doses of 1.5 keV X-rays under dry N2 at atmospheric pressure and room temperature. For each different thickness, the damage is assessed by measuring the loss of the supercoiled configuration as a function of incident photon fluence. From the exposure curves, the G-values are deduced, assuming that X-ray photons interacting with DNA, deposit all of their energy in the film. The results show that the G-value (i.e., damage per unit of deposited energy) increases with film thickness and reaches a plateau at 30±5 nm. This thickness dependence provides a correction factor to estimate the actual G-value for films with thicknesses below 30nm thickness. Thus, the absolute values of damage can be compared with that of films of any thickness under different experimental conditions. PMID:22562941

  5. Effects of laser acupuncture on blood perfusion rate

    NASA Astrophysics Data System (ADS)

    Wang, Xian-ju; Zeng, Chang-chun; Liu, Han-ping; Liu, Song-hao; Liu, Liang-gang

    2006-09-01

    Based on Pennes equation, the influences of the intensity and the impulse frequency of laser acupuncture on the point tissues' blood flow perfusion rate are discussed. We find that the blood perfusion rate of point tissue increases with the intensity of laser acupuncture increasing. After impulse laser acupuncture the point tissue blood perfusion rate increase little, but after continuum laser acupuncture the point tissues blood perfusion rate increase much.

  6. Kidney in potassium depletion. II. K/sup +/ handling by the isolated perfused rat kidney

    SciTech Connect

    Hayashi, M.; Katz, A.I.

    1987-03-01

    In a companion paper the authors reported a large increment in Na/sup +/-K/sup +/-ATPase activity and (/sup 3/H)ouabain binding the inner stripe of outer medullary collecting tubules from K-depleted rats. To test the hypothesis that the increased number of Na/sup +/-K/sup +/ pumps in these animals may be involved in potassium reabsorption they examined the effect of ouabain on K excretion by isolated, perfused kidneys from rats fed a K-free diet for 3 wk. Kidneys from K-depleted rats retain potassium avidly, both the fractional (FE/sub K/) and absolute K excretion being approximately fivefold lower than in control kidneys. Ouabain (5 mM) increased FE/sub K/ in kidneys from each K-depleted rat; similar results were obtained when kidneys were perfused with low and high potassium concentrations. In contrast, ouabain produced a variable effect in control kidneys, that depended on the perfusate potassium concentration. In K-depleted rats amiloride did not significantly alter K excretion and did not block the ouabain-induced kaliuresis, suggesting that the latter is not due to enhanced secretion secondary to increased distal fluid delivery. These results provide evidence for ouabain-sensitive potassium reabsorption in kidneys of chronically K-depleted rats, and suggest an explanation for the increased Na/sup +/-K/sup +/-ATPase observed in such animals.

  7. Quantitative 31P nuclear magnetic resonance analysis of metabolite concentrations in Langendorff-perfused rabbit hearts.

    PubMed Central

    Gard, J K; Kichura, G M; Ackerman, J J; Eisenberg, J D; Billadello, J J; Sobel, B E; Gross, R W

    1985-01-01

    The quantitative analysis of the mobile high-energy phosphorus metabolites in isovolumic Langendorff-perfused rabbit hearts has been performed by 31P NMR utilizing rapid pulse repetition to optimize sensitivity. Absolute quantification required reference to an external standard, determination of differential magnetization saturation and resonance peak area integration by Lorentzian lineshape analysis. Traditionally accepted hemodynamic indices (LVDP, dp/dt) and biochemical indices (lactate, pyruvate) of myocardial function were measured concomitantly with all NMR determinations. Hemodynamically and biochemically competent Langendorff-perfused rabbit hearts were found to have intracellular PCr, ATP, GPC, and Pi concentrations of 14.95 +/- 0.25, 8.08 +/- 0.13, 5.20 +/- 0.58 and 2.61 +/- 0.47 mM respectively. Intracellular pH was 7.03 +/- 0.01. Cytosolic ADP concentration was derived from a creatine kinase equilibrium model and determined to be approximately 36 microM. Reduction of perfusate flow from 20 to 2.5 ml/min demonstrated statistically significant decreases in PCr, ATP, and pH as well as an increase in Pi that correlated closely with the independent hemodynamic and biochemical indices of myocardial function. The decrease in ATP and PCr concentrations precisely matched the increase in Pi during reduced flow. These results constitute the first quantitative determination of intracellular metabolite concentrations by 31P NMR in intact rabbit myocardium under physiologic and low flow conditions. PMID:4074839

  8. Validation of a Perfusion Registry: Methodological Approach and Initial Findings

    PubMed Central

    Paugh, Theron A.; Dickinson, Timothy A.; Theurer, Patricia F.; Bell, Gail F.; Shann, Kenneth G.; Baker, Robert A.; Mellas, Nicholas B.; Prager, Richard L.; Likosky, Donald S.

    2012-01-01

    Abstract: Although regional and national registries exist to measure and report performance of cardiac surgical programs, few registries exist dedicated to the practice of cardiopulmonary bypass (CPB). We developed and implemented a cardiovascular perfusion registry (Perfusion Measures and outcomes [PERForm] Registry) within the structure of the Michigan Society of Thoracic and Cardiovascular Surgeons (MSTCVS) to improve our understanding of the practice of CPB. The PERForm Registry comprises data elements describing the practice of CPB. Fourteen medical centers within MSTCVS have voluntarily reported these data on procedures in which CPB is used. We validated the case count among procedures performed between January 1, 2011 to December 31, 2011, and validated the values among 20 fields at three medical centers. We queried database managers at all 14 medical centers to identify the infrastructure that contributed to best overall data collection performance. We found that 98% of all records submitted to the PERForm and 95% of those submitted to the Society of Thoracic Surgeons (STS) matched. We found quite favorable agreement in our audit of select fields (95.8%). Those centers with the most favorable performance in this validation study were more likely to use electronic data capture, have a perfusionist as the STS database manager, and have involvement of the STS database manager in the PERForm or STS databases. We successfully and accurately collected data concerning cardiovascular perfusion among 14 institutions in conjunction with the MSTCVS. Future efforts will focus on expanding data collection to all MSTCVS participating institutions as well as more broadly outside of Michigan. PMID:23198390

  9. Stability of radiomic features in CT perfusion maps.

    PubMed

    Bogowicz, M; Riesterer, O; Bundschuh, R A; Veit-Haibach, P; Hüllner, M; Studer, G; Stieb, S; Glatz, S; Pruschy, M; Guckenberger, M; Tanadini-Lang, S

    2016-12-21

    This study aimed to identify a set of stable radiomic parameters in CT perfusion (CTP) maps with respect to CTP calculation factors and image discretization, as an input for future prognostic models for local tumor response to chemo-radiotherapy. Pre-treatment CTP images of eleven patients with oropharyngeal carcinoma and eleven patients with non-small cell lung cancer (NSCLC) were analyzed. 315 radiomic parameters were studied per perfusion map (blood volume, blood flow and mean transit time). Radiomics robustness was investigated regarding the potentially standardizable (image discretization method, Hounsfield unit (HU) threshold, voxel size and temporal resolution) and non-standardizable (artery contouring and noise threshold) perfusion calculation factors using the intraclass correlation (ICC). To gain added value for our model radiomic parameters correlated with tumor volume, a well-known predictive factor for local tumor response to chemo-radiotherapy, were excluded from the analysis. The remaining stable radiomic parameters were grouped according to inter-parameter Spearman correlations and for each group the parameter with the highest ICC was included in the final set. The acceptance level was 0.9 and 0.7 for the ICC and correlation, respectively. The image discretization method using fixed number of bins or fixed intervals gave a similar number of stable radiomic parameters (around 40%). The potentially standardizable factors introduced more variability into radiomic parameters than the non-standardizable ones with 56-98% and 43-58% instability rates, respectively. The highest variability was observed for voxel size (instability rate  >97% for both patient cohorts). Without standardization of CTP calculation factors none of the studied radiomic parameters were stable. After standardization with respect to non-standardizable factors ten radiomic parameters were stable for both patient cohorts after correction for inter-parameter correlations. Voxel size

  10. Stability of radiomic features in CT perfusion maps

    NASA Astrophysics Data System (ADS)

    Bogowicz, M.; Riesterer, O.; Bundschuh, R. A.; Veit-Haibach, P.; Hüllner, M.; Studer, G.; Stieb, S.; Glatz, S.; Pruschy, M.; Guckenberger, M.; Tanadini-Lang, S.

    2016-12-01

    This study aimed to identify a set of stable radiomic parameters in CT perfusion (CTP) maps with respect to CTP calculation factors and image discretization, as an input for future prognostic models for local tumor response to chemo-radiotherapy. Pre-treatment CTP images of eleven patients with oropharyngeal carcinoma and eleven patients with non-small cell lung cancer (NSCLC) were analyzed. 315 radiomic parameters were studied per perfusion map (blood volume, blood flow and mean transit time). Radiomics robustness was investigated regarding the potentially standardizable (image discretization method, Hounsfield unit (HU) threshold, voxel size and temporal resolution) and non-standardizable (artery contouring and noise threshold) perfusion calculation factors using the intraclass correlation (ICC). To gain added value for our model radiomic parameters correlated with tumor volume, a well-known predictive factor for local tumor response to chemo-radiotherapy, were excluded from the analysis. The remaining stable radiomic parameters were grouped according to inter-parameter Spearman correlations and for each group the parameter with the highest ICC was included in the final set. The acceptance level was 0.9 and 0.7 for the ICC and correlation, respectively. The image discretization method using fixed number of bins or fixed intervals gave a similar number of stable radiomic parameters (around 40%). The potentially standardizable factors introduced more variability into radiomic parameters than the non-standardizable ones with 56-98% and 43-58% instability rates, respectively. The highest variability was observed for voxel size (instability rate  >97% for both patient cohorts). Without standardization of CTP calculation factors none of the studied radiomic parameters were stable. After standardization with respect to non-standardizable factors ten radiomic parameters were stable for both patient cohorts after correction for inter-parameter correlations. Voxel size

  11. Absolute Distance Measurement with the MSTAR Sensor

    NASA Technical Reports Server (NTRS)

    Lay, Oliver P.; Dubovitsky, Serge; Peters, Robert; Burger, Johan; Ahn, Seh-Won; Steier, William H.; Fetterman, Harrold R.; Chang, Yian

    2003-01-01

    The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. The sensor uses a single laser in conjunction with fast phase modulators and low frequency detectors. We describe the design of the system - the principle of operation, the metrology source, beamlaunching optics, and signal processing - and show results for target distances up to 1 meter. We then demonstrate how the system can be scaled to kilometer-scale distances.

  12. Decreases in Molecular Diffusion, Perfusion Fraction and Perfusion-Related Diffusion in Fibrotic Livers: A Prospective Clinical Intravoxel Incoherent Motion MR Imaging Study

    PubMed Central

    Lu, Pu-Xuan; Huang, Hua; Yuan, Jing; Zhao, Feng; Chen, Zhi-Yi; Zhang, Qinwei; Ahuja, Anil T.; Zhou, Bo-Ping; Wáng, Yì-Xiáng J.

    2014-01-01

    Purpose This study was aimed to determine whether pure molecular-based diffusion coefficient (D) and perfusion-related diffusion parameters (perfusion fraction f, perfusion-related diffusion coefficient D*) differ in healthy livers and fibrotic livers through intra-voxel incoherent motion (IVIM) MR imaging. Material and Methods 17 healthy volunteers and 34 patients with histopathologically confirmed liver fibrosis patients (stage 1 = 14, stage 2 = 8, stage 3& 4 = 12, METAVIR grading) were included. Liver MR imaging was performed at 1.5-T. IVIM diffusion weighted imaging sequence was based on standard single-shot DW spin echo-planar imaging, with ten b values of 10, 20, 40, 60, 80, 100, 150, 200, 400, 800 sec/mm2 respectively. Pixel-wise realization and regions-of-interest based quantification of IVIM parameters were performed. Results D, f, and D* in healthy volunteer livers and patient livers were 1.096±0.155 vs 0.917±0.152 (10−3 mm2/s, p = 0.0015), 0.164±0.021 vs 0.123±0.029 (p<0.0001), and 13.085±2.943 vs 9.423±1.737 (10−3 mm2/s, p<0.0001) respectively, all significantly lower in fibrotic livers. As the fibrosis severity progressed, D, f, and D* values decreased, with a trend significant for f and D*. Conclusion Fibrotic liver is associated with lower pure molecular diffusion, lower perfusion volume fraction, and lower perfusion-related diffusion. The decrease of f and D* in the liver is significantly associated liver fibrosis severity. PMID:25436458

  13. Perfusion MRI: The Five Most Frequently Asked Clinical Questions

    PubMed Central

    Essig, Marco; Nguyen, Thanh Binh; Shiroishi, Mark S.; Saake, Marc; Provenzale, James M.; Enterline, David S.; Anzalone, Nicoletta; Dörfler, Arnd; Rovira, Àlex; Wintermark, Max; Law, Meng

    2013-01-01

    OBJECTIVE This article addresses questions that radiologists frequently ask when planning, performing, processing, and interpreting MRI perfusion studies in CNS imaging. CONCLUSION Perfusion MRI is a promising tool in assessing stroke, brain tumors, and neurodegenerative diseases. Most of the impediments that have limited the use of perfusion MRI can be overcome to allow integration of these methods into modern neuroimaging protocols. PMID:23971482

  14. Role of hypothermic machine perfusion in liver transplantation.

    PubMed

    Schlegel, Andrea; Dutkowski, Philipp

    2015-06-01

    Machine liver perfusion has significantly evolved during the last ten years to optimize extended criteria liver grafts and to address the worldwide organ shortage. This review gives an overview on available ex vivo and in vivo data on hypothermic machine liver perfusion. We discuss also possible protective pathways and show most recent clinical applications of hypothermic machine liver perfusion in human.

  15. Neutron activation analysis of certified samples by the absolute method

    NASA Astrophysics Data System (ADS)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  16. Parametric myocardial perfusion PET imaging using physiological clustering

    NASA Astrophysics Data System (ADS)

    Mohy-ud-Din, Hassan; Karakatsanis, Nikolaos A.; Lodge, Martin A.; Tang, Jing; Rahmim, Arman

    2014-03-01

    We propose a novel framework of robust kinetic parameter estimation applied to absolute ow quanti cation in dynamic PET imaging. Kinetic parameter estimation is formulated as a nonlinear least squares with spatial constraints problem (NLLS-SC) where the spatial constraints are computed from a physiologically driven clustering of dynamic images, and used to reduce noise contamination. An ideal clustering of dynamic images depends on the underlying physiology of functional regions, and in turn, physiological processes are quanti ed by kinetic parameter estimation. Physiologically driven clustering of dynamic images is performed using a clustering algorithm (e.g. K-means, Spectral Clustering etc) with Kinetic modeling in an iterative handshaking fashion. This gives a map of labels where each functionally homogenous cluster is represented by mean kinetics (cluster centroid). Parametric images are acquired by solving the NLLS-SC problem for each voxel which penalizes spatial variations from its mean kinetics. This substantially reduces noise in the estimation process for each voxel by utilizing kinetic information from physiologically similar voxels (cluster members). Resolution degradation is also substantially minimized as no spatial smoothing between heterogeneous functional regions is performed. The proposed framework is shown to improve the quantitative accuracy of Myocardial Perfusion (MP) PET imaging, and in turn, has the long-term potential to enhance capabilities of MP PET in the detection, staging and management of coronary artery disease.

  17. In systemic sclerosis skin perfusion of hands is reduced and may predict the occurrence of new digital ulcers.

    PubMed

    Barbano, Biagio; Marra, Alessandro Maria; Quarta, Silvia; Gigante, Antonietta; Barilaro, Giuseppe; Gasperini, Maria Ludovica; Rosato, Edoardo

    2017-03-01

    Systemic sclerosis (SSc) patients are at high risk for the development of ischemic digital ulcers (DUs). The aim of this study was to assess in SSc patients a correlation between skin perfusion evaluated by LDPI and DUs and to evaluate the prognostic value of skin perfusion to predict the new DUs occurrence. Fifty eight (47 female, 11 male) SSc patients were enrolled. Skin perfusion of hands and region of interest (ROIs) was measured by Laser Doppler perfusion Imager (LDPI). The proximal-distal gradient (PDG) was present when the perfusion mean difference between ROI1 and ROI2 was >30 pU. The skin perfusion of hands is lower in SSc patients than in healthy controls. The skin perfusion decreased with severity of capillaroscopic damage. Both mean perfusion of hand and PDG are significantly (p<0.01 and p<0.0001, respectively) lower in SSc patients with new DUs than in SSc patients without DUs. Only 2 of 11 SSc patients (18.2%) with PDG developed new digital ulcers, conversely 36 of 47 (76.6%) SSc patients without PDG developed new digital ulcers (p<0.001). The ROC curves demonstrated a good accuracy of new DUs prediction for PDG (0.78, p<0.0001). Using this cut-off value of 30 pU, RR for new DUs development in SSc patients without PDG is 4,2 (p<0.001). LDPI indices could be used in association to the capillaroscopic and clinical findings or serological tests in the identification of patients at high risk of developing DUs.

  18. Lung Perfusion Scanning in Hepatic Cirrhosis

    PubMed Central

    Stanley, N. N.; Ackrill, P.; Wood, J.

    1972-01-01

    Abnormal lung perfusion scans using radioactive particles were found in five out of six cases of hepatic cirrhosis with arterial hypoxaemia. None had clinical evidence of cardiopulmonary disease or signs of pulmonary embolism on arteriography. The scan defects are probably caused by a disorder of the pulmonary microvasculature, which may show regional variation in severity. ImagesFIG. 1FIG. 2 PMID:4645896

  19. Coupling between resting cerebral perfusion and EEG.

    PubMed

    O'Gorman, R L; Poil, S-S; Brandeis, D; Klaver, P; Bollmann, S; Ghisleni, C; Lüchinger, R; Martin, E; Shankaranarayanan, A; Alsop, D C; Michels, L

    2013-07-01

    While several studies have investigated interactions between the electroencephalography (EEG) and functional magnetic resonance imaging BOLD signal fluctuations, less is known about the associations between EEG oscillations and baseline brain haemodynamics, and few studies have examined the link between EEG power outside the alpha band and baseline perfusion. Here we compare whole-brain arterial spin labelling perfusion MRI and EEG in a group of healthy adults (n = 16, ten females, median age: 27 years, range 21-48) during an eyes closed rest condition. Correlations emerged between perfusion and global average EEG power in low (delta: 2-4 Hz and theta: 4-7 Hz), middle (alpha: 8-13 Hz), and high (beta: 13-30 Hz and gamma: 30-45 Hz) frequency bands in both cortical and sub-cortical regions. The correlations were predominately positive in middle and high-frequency bands, and negative in delta. In addition, central alpha frequency positively correlated with perfusion in a network of brain regions associated with the modulation of attention and preparedness for external input, and central theta frequency correlated negatively with a widespread network of cortical regions. These results indicate that the coupling between average EEG power/frequency and local cerebral blood flow varies in a frequency specific manner. Our results are consistent with longstanding concepts that decreasing EEG frequencies which in general map onto decreasing levels of activation.

  20. Nuclear cardiology: Myocardial perfusion and function

    SciTech Connect

    Seldin, D.W. )

    1991-08-01

    Myocardial perfusion studies continue to be a major focus of research, with new investigations of the relationship of exercise-redistribution thallium imaging to diagnosis, prognosis, and case management. The redistribution phenomenon, which seemed to be fairly well understood a few years ago, is now recognized to be much more complex than originally thought, and various strategies have been proposed to clarify the meaning of persistent defects. Pharmacologic intervention with dipyridamole and adenosine has become available as an alternative to exercise, and comparisons with exercise imaging and catheterization results have been described. Thallium itself is no longer the sole single-photon perfusion radiopharmaceutical; two new technetium agents are now widely available. In addition to perfusion studies, advances in the study of ventricular function have been made, including reports of studies performed in conjunction with technetium perfusion studies, new insights into cardiac physiology, and the prognostic and case-management information that function studies provide. Finally, work has continued with monoclonal antibodies for the identification of areas of myocyte necrosis. 41 references.

  1. A reappraisal of retrograde cerebral perfusion

    PubMed Central

    2013-01-01

    Brain protection during aortic arch surgery by perfusing cold oxygenated blood into the superior vena cava was first reported by Lemole et al. In 1990 Ueda and associates first described the routine use of continuous retrograde cerebral perfusion (RCP) in thoracic aortic surgery for the purpose of cerebral protection during the interval of obligatory interruption of anterograde cerebral flow. The beneficial effects of RCP may be its ability to sustain brain hypothermia during hypothermic circulatory arrest (HCA) and removal of embolic material from the arterial circulation of the brain. RCP can offer effective brain protection during HCA for about 40 to 60 minutes. Animal experiments revealed that RCP provided inadequate cerebral perfusion and that neurological recovery was improved with selective antegrade cerebral perfusion (ACP), however, both RCP and ACP provide comparable clinical outcomes regarding both the mortality and stroke rates by risk-adjusted and case-matched comparative study. RCP still remains a valuable adjunct for brain protection during aortic arch repair in particular pathologies and patients. PMID:23977600

  2. Asynchronicity of facial blood perfusion in migraine.

    PubMed

    Zaproudina, Nina; Teplov, Victor; Nippolainen, Ervin; Lipponen, Jukka A; Kamshilin, Alexei A; Närhi, Matti; Karjalainen, Pasi A; Giniatullin, Rashid

    2013-01-01

    Asymmetrical changes in blood perfusion and asynchronous blood supply to head tissues likely contribute to migraine pathophysiology. Imaging was widely used in order to understand hemodynamic variations in migraine. However, mapping of blood pulsations in the face of migraineurs has not been performed so far. We used the Blood Pulsation Imaging (BPI) technique, which was recently developed in our group, to establish whether 2D-imaging of blood pulsations parameters can reveal new biomarkers of migraine. BPI characteristics were measured in migraineurs during the attack-free interval and compared to healthy subjects with and without a family history of migraine. We found a novel phenomenon of transverse waves of facial blood perfusion in migraineurs in contrast to healthy subjects who showed synchronous blood delivery to both sides of the face. Moreover, the amplitude of blood pulsations was symmetrically distributed over the face of healthy subjects, but asymmetrically in migraineurs and subjects with a family history of migraine. In the migraine patients we found a remarkable correlation between the side of unilateral headache and the direction of the blood perfusion wave. Our data suggest that migraine is associated with lateralization of blood perfusion and asynchronous blood pulsations in the facial area, which could be due to essential dysfunction of the autonomic vascular control in the face. These findings may further enhance our understanding of migraine pathophysiology and suggest new easily available biomarkers of this pathology.

  3. Asynchronicity of Facial Blood Perfusion in Migraine

    PubMed Central

    Zaproudina, Nina; Teplov, Victor; Nippolainen, Ervin; Lipponen, Jukka A.; Kamshilin, Alexei A.; Närhi, Matti; Karjalainen, Pasi A.; Giniatullin, Rashid

    2013-01-01

    Asymmetrical changes in blood perfusion and asynchronous blood supply to head tissues likely contribute to migraine pathophysiology. Imaging was widely used in order to understand hemodynamic variations in migraine. However, mapping of blood pulsations in the face of migraineurs has not been performed so far. We used the Blood Pulsation Imaging (BPI) technique, which was recently developed in our group, to establish whether 2D-imaging of blood pulsations parameters can reveal new biomarkers of migraine. BPI characteristics were measured in migraineurs during the attack-free interval and compared to healthy subjects with and without a family history of migraine. We found a novel phenomenon of transverse waves of facial blood perfusion in migraineurs in contrast to healthy subjects who showed synchronous blood delivery to both sides of the face. Moreover, the amplitude of blood pulsations was symmetrically distributed over the face of healthy subjects, but asymmetrically in migraineurs and subjects with a family history of migraine. In the migraine patients we found a remarkable correlation between the side of unilateral headache and the direction of the blood perfusion wave. Our data suggest that migraine is associated with lateralization of blood perfusion and asynchronous blood pulsations in the facial area, which could be due to essential dysfunction of the autonomic vascular control in the face. These findings may further enhance our understanding of migraine pathophysiology and suggest new easily available biomarkers of this pathology. PMID:24324592

  4. Comparative vs. Absolute Judgments of Trait Desirability

    ERIC Educational Resources Information Center

    Hofstee, Willem K. B.

    1970-01-01

    Reversals of trait desirability are studied. Terms indicating conservativw behavior appeared to be judged relatively desirable in comparative judgement, while traits indicating dynamic and expansive behavior benefited from absolute judgement. The reversal effect was shown to be a general one, i.e. reversals were not dependent upon the specific…

  5. New Techniques for Absolute Gravity Measurements.

    DTIC Science & Technology

    1983-01-07

    Hammond, J.A. (1978) Bollettino Di Geofisica Teorica ed Applicata Vol. XX. 8. Hammond, J. A., and Iliff, R. L. (1979) The AFGL absolute gravity system...International Gravimetric Bureau, No. L:I-43. 7. Hammond. J.A. (1978) Bollettino Di Geofisica Teorica ed Applicata Vol. XX. 8. Hammond, J.A., and

  6. An Absolute Electrometer for the Physics Laboratory

    ERIC Educational Resources Information Center

    Straulino, S.; Cartacci, A.

    2009-01-01

    A low-cost, easy-to-use absolute electrometer is presented: two thin metallic plates and an electronic balance, usually available in a laboratory, are used. We report on the very good performance of the device that allows precise measurements of the force acting between two charged plates. (Contains 5 footnotes, 2 tables, and 6 figures.)

  7. Stimulus Probability Effects in Absolute Identification

    ERIC Educational Resources Information Center

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  8. Absolute Positioning Using the Global Positioning System

    DTIC Science & Technology

    1994-04-01

    Global Positioning System ( GPS ) has becom a useful tool In providing relativ survey...Includes the development of a low cost navigator for wheeled vehicles. ABSTRACT The Global Positioning System ( GPS ) has become a useful tool In providing...technique of absolute or point positioning involves the use of a single Global Positioning System ( GPS ) receiver to determine the three-dimenslonal

  9. On the convective-absolute nature of river bedform instabilities

    NASA Astrophysics Data System (ADS)

    Vesipa, Riccardo; Camporeale, Carlo; Ridolfi, Luca; Chomaz, Jean Marc

    2014-12-01

    River dunes and antidunes are induced by the morphological instability of stream-sediment boundary. Such bedforms raise a number of subtle theoretical questions and are crucial for many engineering and environmental problems. Despite their importance, the absolute/convective nature of the instability has never been addressed. The present work fills this gap as we demonstrate, by the cusp map method, that dune instability is convective for all values of the physical control parameters, while the antidune instability exhibits both behaviors. These theoretical predictions explain some previous experimental and numerical observations and are important to correctly plan flume experiments, numerical simulations, paleo-hydraulic reconstructions, and river works.

  10. Near-infrared spectroscopy and indocyanine green derived blood flow index for noninvasive measurement of muscle perfusion during exercise.

    PubMed

    Habazettl, Helmut; Athanasopoulos, Dimitris; Kuebler, Wolfgang M; Wagner, Harrieth; Roussos, Charis; Wagner, Peter D; Ungruhe, Juergen; Zakynthinos, Spyros; Vogiatzis, Ioannis

    2010-04-01

    Near-infrared spectroscopy (NIRS) with the tracer indocyanine green (ICG) may be used for measuring muscle blood flow (MBF) during exercise, if arterial ICG concentration is measured simultaneously. Although pulse dye densitometry allows for noninvasive measurement of arterial dye concentration, this technique is sensitive to motion and may not be applicable during exercise. The aim of this study was to evaluate a noninvasive blood flow index (BFI), which is derived solely from the muscle ICG concentration curve. In 10 male cyclists 5 mg ICG were injected into an antecubital vein at rest and during cycling at 30, 60, 70, 80, 90, and 100% of previously determined maximal work load. Simultaneously blood was withdrawn through a photodensitometer at 20 ml/min from the radial artery to measure arterial ICG concentration. To measure muscle tissue ICG concentrations, two sets of NIRS optodes were positioned on the skin, one over the left seventh intercostal space and the other over the left vastus lateralis muscle. MBF was calculated from the arterial and muscle concentration data according to Fick's principle. BFI was calculated solely from the muscle concentration curve as ICG concentration difference divided by rise time between 10 and 90% of peak. During exercise mean BFI values changed similarly to MBF in both intercostal and quadriceps muscles and showed excellent correlations with MBF: r = 0.98 and 0.96, respectively. Individual data showed some scattering among BFI and MBF values but still reasonable correlations of BFI with MBF: r = 0.73 and 0.72 for intercostal and quadriceps muscles, respectively. Interobserver variability, as analyzed by Bland-Altman plots, was considerably less for BFI than MBF. These data suggest that BFI can be used for measuring changes in muscle perfusion from rest to maximal exercise. Although absolute blood flow cannot be determined, BFI has the advantages of being essentially noninvasive and having low interobserver variability.

  11. Recent developments and future prospects of SPECT myocardial perfusion imaging.

    PubMed

    Zaman, Maseeh Uz; Hashmi, Ibrahim; Fatima, Nosheen

    2010-10-01

    Myocardial perfusion SPECT imaging is the most commonly performed functional imaging for assessment of coronary artery disease. High diagnostic accuracy and incremental prognostic value are the major benefits while suboptimal spatial resolution and significant radiation exposure are the main limitations. Its ability to detect hemodynamic significance of lesions seen on multidetector CT angiogram (MDCTA) has paved the path for a successful marriage between anatomical and functional imaging modalities in the form of hybrid SPECT/MDCTA system. In recent years, there have been enormous efforts by industry and academia to develop new SPECT imaging systems with better sensitivity, resolution, compact design and new reconstruction algorithms with ability to improve image quality and resolution. Furthermore, expected arrival of Tc-99m-labeled deoxyglucose in next few years would further strengthen the role of SPECT in imaging hibernating myocardium. In view of these developments, it seems that SPECT would enjoy its pivotal role in spite of major threat to be replaced by fluorine-18-labeled positron emission tomography perfusion and glucose metabolism imaging agents.

  12. Thermal tests for laser Doppler perfusion measurements in Raynaud's syndrome

    NASA Astrophysics Data System (ADS)

    Kacprzak, Michal; Skora, A.; Obidzinska, J.; Zbiec, A.; Maniewski, Roman; Staszkiewicz, W.

    2004-07-01

    The laser Doppler method offers a non-invasive, real time technique for monitoring of blood perfusion in microcirculation. In practical measurements the perfusion index is given only in relative values. Thus, accurate and reproducible results can be only obtained when using a well controlled stimulation test. The aim of this study was evaluation of the thermal stimulation test, which is frequently used to investigate microcirculation in patients with Raynaud's syndrome. Three types of thermal tests, in which air or water with temperature in range 5°C - 40°C were used. Ten normal volunteers and fifteen patients with clinical symptoms of the primary Raynaud's syndrome were enrolled in this study. To estimate skin microcirculation changes during the thermal test, the multichannel laser Doppler system and laser Doppler scanner were used. The obtained results were analyzed from the point of view of the efficiency of these methods and the thermal provocative tests in differentiation of normal subjects and patient with Raynaud's syndrome.

  13. Myocardial Perfusion SPECT Imaging in Patients after Percutaneous Coronary Intervention.

    PubMed

    Georgoulias, Panagiotis; Valotassiou, Varvara; Tsougos, Ioannis; Demakopoulos, Nikolaos

    2010-05-01

    Coronary artery disease (CAD) is the most prevalent form of cardiovascular disease affecting about 13 million Americans, while more than one million percutaneous transluminal intervention (PCI) procedures are performed annually in the USA. The relative high occurrence of restenosis, despite stent implementation, seems to be the primary limitation of PCI. Over the last decades, single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), has proven an invaluable tool for the diagnosis of CAD and patients' risk stratification, providing useful information regarding the decision about revascularization and is well suited to assess patients after intervention. Information gained from post-intervention MPI is crucial to differentiate patients with angina from those with exo-cardiac chest pain syndromes, to assess peri-intervention myocardial damage, to predict-detect restenosis after PCI, to detect CAD progression in non-revascularized vessels, to evaluate the effects of intervention if required for occupational reasons and to evaluate patients' long-term prognosis. On the other hand, chest pain and exercise electrocardiography are largely unhelpful in identifying patients at risk after PCI.Although there are enough published data demonstrating the value of myocardial perfusion SPECT imaging in patients after PCI, there is still debate on whether or not these tests should be performed routinely.

  14. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    PubMed Central

    Handayani, A.; Dijkstra, H.; Prakken, N. H. J.; Slart, R. H. J. A.; Oudkerk, M.; Van Ooijen, P. M. A.; Vliegenthart, R.; Sijens, P. E.

    2016-01-01

    Technological advances in magnetic resonance imaging (MRI) and computed tomography (CT), including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET). This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD), as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings. PMID:27088083

  15. The effect of perfusion flow on oxidative metabolism during cardiopulmonary bypass.

    PubMed

    Baraka, A

    1993-06-01

    The influence of perfusion flow rate on whole-body oxygen consumption (VO2), central venous hemoglobin oxygen saturation (SVO2), and central venous arterial oxygen tension (PVO2) during hypothermic hemodilutional nonpulsatile cardiopulmonary bypass was investigated in 20 patients undergoing coronary artery bypass grafting. In 10 patients, the perfusion flow was 2.4 L.min-1 x m-2 (Group I), whereas a flow of 1.2 L.min-1 x m-2 was used in the other 10 patients (Group II). When the body temperature was 29.7 +/- 1.2 degrees C (Group I) and 29.6 +/- 0.8 degrees C (Group II), mixed venous and arterial blood were sampled simultaneously, and whole-body oxygen consumption was calculated. Data collected during hypothermia were compared with the corresponding values achieved after rewarming to 37 degrees C. In both groups, the whole-body oxygen consumption during hypothermia was lower by about 45% than the VO2 after rewarming. However, SVO2 during the low perfusion flow was not significantly different from SVO2 after rewarming, whereas the temperature-corrected PVO2 was significantly lower. In contrast, the high-perfusion flow provided luxury perfusion as evident by the high SVO2, and maintained the temperature-corrected PVO2 within the normothermic range. Thus, maintenance of the normothermic perfusion flow rate during moderate hypothermic hemodilutional cardiopulmonary bypass may provide a safety margin that may compensate for unexpected increase of oxygen consumption or decrease of oxygen delivery.

  16. Selective cerebral perfusion for cerebral protection: what we do know

    PubMed Central

    Tang, Gilbert H. L.

    2013-01-01

    Selective antegrade cerebral perfusion (SACP) for aortic arch surgery has evolved considerably since it was first reported. Various pressure rates have been investigated through animal models, as has the effect of warmer perfusate temperatures and hematocrit. Clinical research into pH management, the role of unilateral and bilateral perfusion, and core temperatures have further refined the procedure. We recommend the following protocol for SACP: perfusion pressure between 40-60 mmHg, flow rates between 6-10 mL/kg/min, and perfusate temperature of 20-28 °C; core cooling to 18-30 °C contingent on duration of arrest; alpha-stat pH management; hematocrit between 25-30%; near infrared spectroscopy to monitor cerebral perfusion; and bilateral perfusion when prolonged durations of SACP is anticipated. PMID:23977601

  17. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    SciTech Connect

    Dowdle, S.C.; Human, D.G.; Mann, M.D. )

    1990-08-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis.

  18. Absolute Transition Probabilities of Lines in the Spectra of Astrophysical Atoms, Molecules, and Ions

    NASA Technical Reports Server (NTRS)

    Parkinson, W. H.; Smith, P. L.; Yoshino, K.

    1984-01-01

    Progress in the investigation of absolute transition probabilities (A-values or F values) for ultraviolet lines is reported. A radio frequency ion trap was used for measurement of transition probabilities for intersystem lines seen in astronomical spectra. The intersystem line at 2670 A in Al II, which is seen in pre-main sequence stars and symbiotic stars, was studied.

  19. Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

    SciTech Connect

    Strydhorst, Jared H. Ruddy, Terrence D.; Wells, R. Glenn

    2015-04-15

    Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with {sup 99m}Tc and {sup 201}Tl single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with {sup 99m}Tc-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with {sup 201}Tl and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolute uptake of {sup 99m}Tc in the heart was also quantified with and without attenuation correction. Results: For {sup 99m}Tc imaging, relative segmental perfusion changed by up to +2.1%/−1.8% as a result of attenuation correction. Relative changes of +3.6%/−1.0% were observed for the {sup 201}Tl images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected {sup 99m}Tc scans, and 3.6% and 4.3%, respectively, for the {sup 201}Tl scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake.

  20. Effects of BRL 38227, sodium nitroprusside and verapamil on collateral perfusion following acute arterial occlusion in the rabbit isolated ear.

    PubMed Central

    Randall, M. D.; Griffith, T. M.

    1992-01-01

    1. We have used an isolated, buffer-perfused, rabbit ear model of acute arterial occlusion to investigate the effects of the nitrovasodilator sodium nitroprusside, the potassium channel activator BRL 38227 (the active (-)-enantiomer of cromakalim) and the calcium antagonist, verapamil, on collateral perfusion in the absence of pharmacological tone. 2. Verapamil was the most potent vasodilator (EC50 = 72.6 +/- 32.0 nM) of 5-hydroxytryptamine/histamine-induced tone in the rabbit isolated perfused ear. Sodium nitroprusside and BRL 38227 were less potent with respective EC50 values of 488 +/- 75 nM and 296 +/- 40 nM. Following inhibition of endothelium-derived relaxing factor (EDRF) synthesis, the potency of BRL 38227 was significantly (P less than 0.001) increased with an EC50 of 55.6 +/- 5.0 nM. 3. BRL 38227 at 500 nM and 3 microM induced substantial increases in collateral perfusion following arterial ligation in the absence of pharmacological tone compared to control. Furthermore 3 microM BRL 38227 completely reversed the attenuation of collateral perfusion which followed inhibition of EDRF synthesis with 100 microM NG-nitro-L-arginine methyl ester (L-NAME). 4. Sodium nitroprusside (500 nM and 3 microM) induced modest improvements in collateral perfusion in the early stages after arterial occlusion. 5. Verapamil did not influence collateral perfusion at either of the concentrations used (50 nM and 3 microM), even though it was a potent vasodilator. 6. The results of this study indicate that BRL 38227, and to a much lesser extent sodium nitroprusside, selectively improve collateral perfusion following arterial occlusion, even in the presence of effects of EDRF on acute collateralization, while verapamil has no effect.(ABSTRACT TRUNCATED AT 250 WORDS) Images Figure 1 PMID:1393264

  1. The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.

    PubMed

    van der Plaats, A; Maathuis, M H J; 'T Hart, N A; Bellekom, A A; Hofker, H S; van der Houwen, E B; Verkerke, G J; Leuvenink, H G D; Verdonck, P; Ploeg, R J; Rakhorst, G

    2006-12-01

    To improve preservation of donor livers, we have developed a portable hypothermic machine perfusion (HMP) system as an alternative for static cold storage. A prototype of the system was built and evaluated on functionality. Evaluation criteria included 24 h of adequate pressure controlled perfusion, sufficient oxygenation, a maintained 0-4 degrees C temperature and sterile conditions. Porcine livers were perfused with pump pressures that were set at 4 mmHg (continuous, portal vein) and 30/20 mmHg, at 60 BPM (pulsatile, hepatic artery). Control livers were preserved using the clinical golden standard: static cold storage. In the HMP group, pressure, flow and temperature were continuously monitored for 24 h. At time-points t = 0, 2, 4, 8, 12, and 24 h samples of University of Wisconsin machine preservation solution were taken for measurement of partial oxygen pressure (pO(2)) and lacto-dehydrogenase. Biopsies in every lobe were taken for histology and electron microscopy; samples of ice, preservation solution, liver surface, and bile were taken and cultured to determine sterility. Results showed that temperature was maintained at 0-4 degrees C; perfusion pressure was maintained at 4 mmHg and 30/20 mmHg for portal vein and hepatic artery, respectively. Flow was approximately 350 and 80 ml/min, respectively, but decreased in the portal vein, probably due to edema formation. Arterial pO(2) was kept at 100 kPa. Histology showed complete perfusion of the liver with no major damage to hepatocytes, bile ducts, and non-parenchymal cells compared to control livers. The machine perfusion system complied to the design criteria and will have to demonstrate the superiority of machine perfusion over cold storage in transplant experiments.

  2. Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia.

    PubMed

    Alsop, David C; Detre, John A; Golay, Xavier; Günther, Matthias; Hendrikse, Jeroen; Hernandez-Garcia, Luis; Lu, Hanzhang; MacIntosh, Bradley J; Parkes, Laura M; Smits, Marion; van Osch, Matthias J P; Wang, Danny J J; Wong, Eric C; Zaharchuk, Greg

    2015-01-01

    This review provides a summary statement of recommended implementations of arterial spin labeling (ASL) for clinical applications. It is a consensus of the ISMRM Perfusion Study Group and the European ASL in Dementia consortium, both of whom met to reach this consensus in October 2012 in Amsterdam. Although ASL continues to undergo rapid technical development, we believe that current ASL methods are robust and ready to provide useful clinical information, and that a consensus statement on recommended implementations will help the clinical community to adopt a standardized approach. In this review, we describe the major considerations and trade-offs in implementing an ASL protocol and provide specific recommendations for a standard approach. Our conclusion is that as an optimal default implementation, we recommend pseudo-continuous labeling, background suppression, a segmented three-dimensional readout without vascular crushing gradients, and calculation and presentation of both label/control difference images and cerebral blood flow in absolute units using a simplified model.

  3. Perfusion CT and US of colorectal cancer liver metastases: a correlative study of two dynamic imaging modalities.

    PubMed

    Meijerink, Martijn R; van Waesberghe, Jan Hein T M; van Schaik, Cors; Boven, Epie; van der Veldt, Astrid A M; van den Tol, Petrousjka; Meijer, Sybren; van Kuijk, Cornelis

    2010-10-01

    The purpose of this study was to evaluate the correlation between dynamic-contrast-enhanced computed tomography (DCE-CT) and first-pass dynamic-contrast-enhanced ultrasound (DCE-US) of normal appearing liver parenchyma and of colorectal cancer liver metastases. Thirty patients with hepatic metastases from colorectal cancer underwent DCE-CT and DCE-US. To obtain DCE-US reproducibility measurements, double contrast-passages (2 × 2.4 mL SonoVue intravenous) were acquired. From several DCE-US-derived perfusion indices, the slope-value scored best with a reproducibility concordance correlation coefficient ranging from 0.75-0.93 and overall highest correlation to DCE-CT-derived variables (r = 0.52 to 0.73). The DCE-US-based tumor-to-liver perfusion gradient also showed a low test-retest variability and moderately correlated to DCE-CT (concordance correlation coefficient 0.87-0.92; r = 0.57 to 0.59). To conclude, DCE-US-based slope-value and tumor-to-liver perfusion gradient correlate best with DCE-CT perfusion values. However, both techniques cannot be used interchangeably. DCE-US should be restricted for studies in which a considerable change in perfusion is expected and for patients with a relatively high tumor blood flow at baseline.

  4. From Hubble's NGSL to Absolute Fluxes

    NASA Technical Reports Server (NTRS)

    Heap, Sara R.; Lindler, Don

    2012-01-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R-l000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18-1.00 microns. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsll. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We are therefore developing an observing procedure that should yield fluxes with uncertainties less than 1 % and will take part in an HST proposal to observe up to 15 stars using this new procedure.

  5. Consistent thermostatistics forbids negative absolute temperatures

    NASA Astrophysics Data System (ADS)

    Dunkel, Jörn; Hilbert, Stefan

    2014-01-01

    Over the past 60 years, a considerable number of theories and experiments have claimed the existence of negative absolute temperature in spin systems and ultracold quantum gases. This has led to speculation that ultracold gases may be dark-energy analogues and also suggests the feasibility of heat engines with efficiencies larger than one. Here, we prove that all previous negative temperature claims and their implications are invalid as they arise from the use of an entropy definition that is inconsistent both mathematically and thermodynamically. We show that the underlying conceptual deficiencies can be overcome if one adopts a microcanonical entropy functional originally derived by Gibbs. The resulting thermodynamic framework is self-consistent and implies that absolute temperature remains positive even for systems with a bounded spectrum. In addition, we propose a minimal quantum thermometer that can be implemented with available experimental techniques.

  6. Absolute measurement of length with nanometric resolution

    NASA Astrophysics Data System (ADS)

    Apostol, D.; Garoi, F.; Timcu, A.; Damian, V.; Logofatu, P. C.; Nascov, V.

    2005-08-01

    Laser interferometer displacement measuring transducers have a well-defined traceability route to the definition of the meter. The laser interferometer is de-facto length scale for applications in micro and nano technologies. However their physical unit -half lambda is too large for nanometric resolution. Fringe interpolation-usual technique to improve the resolution-lack of reproducibility could be avoided using the principles of absolute distance measurement. Absolute distance refers to the use of interferometric techniques for determining the position of an object without the necessity of measuring continuous displacements between points. The interference pattern as produced by the interference of two point-like coherent sources is fitted to a geometric model so as to determine the longitudinal location of the target by minimizing least square errors. The longitudinal coordinate of the target was measured with accuracy better than 1 nm, for a target position range of 0.4μm.

  7. Computer processing of spectrograms for absolute intensities.

    PubMed

    Guttman, A; Golden, J; Galbraith, H J

    1967-09-01

    A computer program was developed to process photographically recorded spectra for absolute intensity. Test and calibration films are subjected to densitometric scans that provide digitally recorded densities on magnetic tapes. The nonlinear calibration data are fitted by least-squares cubic polynomials to yield a good approximation to the monochromatic H&D curves for commonly used emulsions (2475 recording film, Royal-X, Tri-X, 4-X). Several test cases were made. Results of these cases show that the machine processed absolute intensities are accurate to within 15%o. Arbitrarily raising the sensitivity threshold by 0.1 density units above gross fog yields cubic polynomial fits to the H&D curves that are radiometrically accurate within 10%. In addition, curves of gamma vs wavelength for 2475, Tri-X, and 4-X emulsions were made. These data show slight evidence of the photographic Purkinje effect in the 2475 emulsion.

  8. An absolute measure for a key currency

    NASA Astrophysics Data System (ADS)

    Oya, Shunsuke; Aihara, Kazuyuki; Hirata, Yoshito

    It is generally considered that the US dollar and the euro are the key currencies in the world and in Europe, respectively. However, there is no absolute general measure for a key currency. Here, we investigate the 24-hour periodicity of foreign exchange markets using a recurrence plot, and define an absolute measure for a key currency based on the strength of the periodicity. Moreover, we analyze the time evolution of this measure. The results show that the credibility of the US dollar has not decreased significantly since the Lehman shock, when the Lehman Brothers bankrupted and influenced the economic markets, and has increased even relatively better than that of the euro and that of the Japanese yen.

  9. Absolute and relative dosimetry for ELIMED

    NASA Astrophysics Data System (ADS)

    Cirrone, G. A. P.; Cuttone, G.; Candiano, G.; Carpinelli, M.; Leonora, E.; Lo Presti, D.; Musumarra, A.; Pisciotta, P.; Raffaele, L.; Randazzo, N.; Romano, F.; Schillaci, F.; Scuderi, V.; Tramontana, A.; Cirio, R.; Marchetto, F.; Sacchi, R.; Giordanengo, S.; Monaco, V.

    2013-07-01

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  10. Silicon Absolute X-Ray Detectors

    SciTech Connect

    Seely, John F.; Korde, Raj; Sprunck, Jacob; Medjoubi, Kadda; Hustache, Stephanie

    2010-06-23

    The responsivity of silicon photodiodes having no loss in the entrance window, measured using synchrotron radiation in the 1.75 to 60 keV range, was compared to the responsivity calculated using the silicon thickness measured using near-infrared light. The measured and calculated responsivities agree with an average difference of 1.3%. This enables their use as absolute x-ray detectors.

  11. Development and validation of a segmentation-free polyenergetic algorithm for dynamic perfusion computed tomography.

    PubMed

    Lin, Yuan; Samei, Ehsan

    2016-07-01

    Dynamic perfusion imaging can provide the morphologic details of the scanned organs as well as the dynamic information of blood perfusion. However, due to the polyenergetic property of the x-ray spectra, beam hardening effect results in undesirable artifacts and inaccurate CT values. To address this problem, this study proposes a segmentation-free polyenergetic dynamic perfusion imaging algorithm (pDP) to provide superior perfusion imaging. Dynamic perfusion usually is composed of two phases, i.e., a precontrast phase and a postcontrast phase. In the precontrast phase, the attenuation properties of diverse base materials (e.g., in a thorax perfusion exam, base materials can include lung, fat, breast, soft tissue, bone, and metal implants) can be incorporated to reconstruct artifact-free precontrast images. If patient motions are negligible or can be corrected by registration, the precontrast images can then be employed as a priori information to derive linearized iodine projections from the postcontrast images. With the linearized iodine projections, iodine perfusion maps can be reconstructed directly without the influence of various influential factors, such as iodine location, patient size, x-ray spectrum, and background tissue type. A series of simulations were conducted on a dynamic iodine calibration phantom and a dynamic anthropomorphic thorax phantom to validate the proposed algorithm. The simulations with the dynamic iodine calibration phantom showed that the proposed algorithm could effectively eliminate the beam hardening effect and enable quantitative iodine map reconstruction across various influential factors. The error range of the iodine concentration factors ([Formula: see text]) was reduced from [Formula: see text] for filtered back-projection (FBP) to [Formula: see text] for pDP. The quantitative results of the simulations with the dynamic anthropomorphic thorax phantom indicated that the maximum error of iodine concentrations can be reduced from

  12. Negative absolute temperature for mobile particles

    NASA Astrophysics Data System (ADS)

    Braun, Simon; Ronzheimer, Philipp; Schreiber, Michael; Hodgman, Sean; Bloch, Immanuel; Schneider, Ulrich

    2013-05-01

    Absolute temperature is usually bound to be strictly positive. However, negative absolute temperature states, where the occupation probability of states increases with their energy, are possible in systems with an upper energy bound. So far, such states have only been demonstrated in localized spin systems with finite, discrete spectra. We realized a negative absolute temperature state for motional degrees of freedom with ultracold bosonic 39K atoms in an optical lattice, by implementing the attractive Bose-Hubbard Hamiltonian. This new state strikingly revealed itself by a quasimomentum distribution that is peaked at maximum kinetic energy. The measured kinetic energy distribution and the extracted negative temperature indicate that the ensemble is close to degeneracy, with coherence over several lattice sites. The state is as stable as a corresponding positive temperature state: The negative temperature stabilizes the system against mean-field collapse driven by negative pressure. Negative temperatures open up new parameter regimes for cold atoms, enabling fundamentally new many-body states. Additionally, they give rise to several counterintuitive effects such as heat engines with above unity efficiency.

  13. System for absolute measurements by interferometric sensors

    NASA Astrophysics Data System (ADS)

    Norton, Douglas A.

    1993-03-01

    The most common problem of interferometric sensors is their inability to measure absolute path imbalance. Presented in this paper is a signal processing system that gives absolute, unambiguous reading of optical path difference for almost any style of interferometric sensor. Key components are a wide band (incoherent) optical source, a polychromator, and FFT electronics. Advantages include no moving parts in the signal processor, no active components at the sensor location, and the use of standard single mode fiber for sensor illumination and signal transmission. Actual absolute path imbalance of the interferometer is determined without using fringe counting or other inferential techniques. The polychromator extracts the interference information that occurs at each discrete wavelength within the spectral band of the optical source. The signal processing consists of analog and digital filtering, Fast Fourier analysis, and a peak detection and interpolation algorithm. This system was originally designed for use in a remote pressure sensing application that employed a totally passive fiber optic interferometer. A performance qualification was made using a Fabry-Perot interferometer and a commercially available laser interferometer to measure the reference displacement.

  14. Chemical composition of French mimosa absolute oil.

    PubMed

    Perriot, Rodolphe; Breme, Katharina; Meierhenrich, Uwe J; Carenini, Elise; Ferrando, Georges; Baldovini, Nicolas

    2010-02-10

    Since decades mimosa (Acacia dealbata) absolute oil has been used in the flavor and perfume industry. Today, it finds an application in over 80 perfumes, and its worldwide industrial production is estimated five tons per year. Here we report on the chemical composition of French mimosa absolute oil. Straight-chain analogues from C6 to C26 with different functional groups (hydrocarbons, esters, aldehydes, diethyl acetals, alcohols, and ketones) were identified in the volatile fraction. Most of them are long-chain molecules: (Z)-heptadec-8-ene, heptadecane, nonadecane, and palmitic acid are the most abundant, and constituents such as 2-phenethyl alcohol, methyl anisate, and ethyl palmitate are present in smaller amounts. The heavier constituents were mainly triterpenoids such as lupenone and lupeol, which were identified as two of the main components. (Z)-Heptadec-8-ene, lupenone, and lupeol were quantified by GC-MS in SIM mode using external standards and represents 6%, 20%, and 7.8% (w/w) of the absolute oil. Moreover, odorant compounds were extracted by SPME and analyzed by GC-sniffing leading to the perception of 57 odorant zones, of which 37 compounds were identified by their odorant description, mass spectrum, retention index, and injection of the reference compound.

  15. On determining absolute entropy without quantum theory or the third law of thermodynamics

    NASA Astrophysics Data System (ADS)

    Steane, Andrew M.

    2016-04-01

    We employ classical thermodynamics to gain information about absolute entropy, without recourse to statistical methods, quantum mechanics or the third law of thermodynamics. The Gibbs-Duhem equation yields various simple methods to determine the absolute entropy of a fluid. We also study the entropy of an ideal gas and the ionization of a plasma in thermal equilibrium. A single measurement of the degree of ionization can be used to determine an unknown constant in the entropy equation, and thus determine the absolute entropy of a gas. It follows from all these examples that the value of entropy at absolute zero temperature does not need to be assigned by postulate, but can be deduced empirically.

  16. The most appropriate position and number for absolute anchorages for orthodontic tooth movements.

    PubMed

    Yu, Jian-Hong; Takakuda, Kazuo; Miyairi, Hiroo; Soma, Kunimichi

    2003-04-01

    Absolute anchorages proved to be very effective for orthodontic tooth movements. We used a 3D digitizer to record each tooth on pre-treatment diagnostic and post-treatment predictive setup models and then 3D coordinate system conversion was performed to make the coordinate values comparable. An arithmetic calculation of vector and moment based on the orthodontic forces and the tooth displacement under preliminary premises undertaken to decide the most favorable position and number for absolute anchorages. Position--For two-dimensional and three-dimensional calculations, the most appropriate positions for absolute anchorages should theoretically be on the line of resultant force (2D) and the plane (3D) where the total moment effect tends to be zero. Number--As for the number of the absolute anchorages needed, it depends on the number of target teeth. Different combinations of target teeth provide different sets of results.

  17. Imaging of drug effects in perfused liver

    NASA Astrophysics Data System (ADS)

    Dammann, Marc; Mahlke, Christine; Kessler, Manfred D.

    2002-06-01

    Various medications affect the systemic circulation and organ oxygenation causing dilatation or constriction of blood vessels. Imminent liver failure can be generated by reduced perfusion of different origins. In this case hepatic vasodilatation would be a therapeutical approach for improving patient's condition. Our examinations have been performed in perfused rat liver using spectrometric methods. Two defined areas of the liver were measured punctually. We compared the influence of Tetramethylpyrazine and Glyceroltrinitrate on hemoglobin oxygenation (HbO2) and concentration (Hb-conc.) in rat liver after application of Norepinephrine, which caused a mid decrease in hemoglobin oxygenation of 47,9 %. Both increased the HbO2, but differed from each other in manner of time and extent. Tetramethylpyrazine indicated a longer effect than Glyceroltrinitrate. Furthermore, HbO2 and Hb-conc. showed a conversed relation. From the shape of the absorption spectra it is possible to derive the oxygenation of hemoglobin.

  18. Effect of cardiac dysrhythmia on cerebral perfusion.

    PubMed

    Sand, B J; Rose, H B; Barker, W F

    1976-07-01

    Extracranial carotid arterial obstructive disease has been the entity most commonly associated with transient cerebrovascular insufficiency. A nonobstructive, frequently overlooked cause of cerebral ischemia is cardiac dysrhythmia. We have explored this by observations of experimental animals and of man. Blood flow and pressure in the carotid arteries of dogs were shown to be decreased by mechnically induced premature ventricular contractions. The significance of the cardiogenic contribution to altered cerebrovascular perfusion was studied by ocular and brachial plethysmography in 210 patients suspected by history of having carotid arterial insufficiency. Of the 210 patients, 62 demonstrated abnormal ocular plethysmographic recordings, and of those, nine had dysrhythmias associated with significant deficits of ocular perfusion. Five patients whose recordings were technically suitable for publication are presented to demonstrate the bizarre ocular plethysmographic recordings seen during the dysrhythmic cycle.

  19. Oxygen saturation, red blood cell tissue fraction and speed resolved perfusion - A new optical method for microcirculatory assessment.

    PubMed

    Jonasson, Hanna; Fredriksson, Ingemar; Pettersson, Anders; Larsson, Marcus; Strömberg, Tomas

    2015-11-01

    We have developed a new fiber-optic system that combines diffuse reflectance spectroscopy (DRS) and laser Doppler Flowmetry (LDF) for a multi-modal assessment of the microcirculation. Quantitative data is achieved with an inverse Monte Carlo algorithm based on an individually adaptive skin model. The output parameters are calculated from the model and given in absolute units: hemoglobin oxygen saturation (%), red blood cell (RBC) tissue fraction (%), and the speed resolved RBC perfusion separated into three speed regions; 0-1mm/s, 1-10mm/s and above 10mm/s (% mm/s). The aim was to explore microcirculatory parameters using the new optical method, integrating DRS and LDF in a joint skin model, during local heating of the dorsal foot and venous and arterial occlusion of the forearm in 23 healthy subjects (age 20-28years). There were differences in the three speed regions in regard to blood flow changes due to local heating, where perfusion for high speeds increased the most. There was also a high correlation between changes in oxygenation and changes in perfusion for higher speeds. Oxygen saturation at baseline was 44% on foot, increasing to 83% at plateau after heating. The larger increase in perfusion for higher speeds than for lower speeds together with the oxygenation increase during thermal provocation, shows a local thermoregulatory blood flow in presumably arteriolar dermal vessels. In conclusion, there are improved possibilities to assess microcirculation using integrated DRS and LDF in a joint skin model by enabling both oxygenation and speed resolved blood flow assessment simultaneously and in the same skin site. Output parameters in absolute units may also yield new insights about the microcirculatory system.

  20. Noncontact blood perfusion mapping in clinical applications

    NASA Astrophysics Data System (ADS)

    Iakovlev, Dmitry; Dwyer, Vincent; Hu, Sijung; Silberschmidt, Vadim

    2016-04-01

    Non-contact imaging photoplethysmography (iPPG) to detect pulsatile blood microcirculation in tissue has been selected as a successor to low spatial resolution and slow scanning blood perfusion techniques currently employed by clinicians. The proposed iPPG system employs a novel illumination source constructed of multiple high power LEDs with narrow spectral emission, which are temporally modulated and synchronised with a high performance sCMOS sensor. To ensure spectrum stability and prevent thermal wavelength drift due to junction temperature variations, each LED features a custom-designed thermal management system to effectively dissipate generated heat and auto-adjust current flow. The use of a multi-wavelength approach has resulted in simultaneous microvascular perfusion monitoring at various tissue depths, which is an added benefit for specific clinical applications. A synchronous detection algorithm to extract weak photoplethysmographic pulse-waveforms demonstrated robustness and high efficiency when applied to even small regions of 5 mm2. The experimental results showed evidences that the proposed system could achieve noticeable accuracy in blood perfusion monitoring by creating complex amplitude and phase maps for the tissue under examination.

  1. Regulation of skeletal muscle perfusion during exercise

    NASA Technical Reports Server (NTRS)

    Delp, M. D.; Laughlin, M. H.

    1998-01-01

    For exercise to be sustained, it is essential that adequate blood flow be provided to skeletal muscle. The local vascular control mechanisms involved in regulating muscle perfusion during exercise include metabolic control, endothelium-mediated control, propagated responses, myogenic control, and the muscle pump. The primary determinant of muscle perfusion during sustained exercise is the metabolic rate of the muscle. Metabolites from contracting muscle diffuse to resistance arterioles and act directly to induce vasodilation, or indirectly to inhibit noradrenaline release from sympathetic nerve endings and oppose alpha-adrenoreceptor-mediated vasoconstriction. The vascular endothelium also releases vasodilator substances (e.g., prostacyclin and nitric oxide) that are prominent in establishing basal vascular tone, but these substances do not appear to contribute to the exercise hyperemia in muscle. Endothelial and smooth muscle cells may also be involved in propagating vasodilator signals along arterioles to parent and daughter vessels. Myogenic autoregulation does not appear to be involved in the exercise hyperemia in muscle, but the rhythmic propulsion of blood from skeletal muscle veins facilitates venous return to the heart and muscle perfusion. It appears that the primary determinants of sustained exercise hyperemia in skeletal muscle are metabolic vasodilation and increased vascular conductance via the muscle pump. Additionally, sympathetic neural control is important in regulating muscle blood flow during exercise.

  2. Inhomogeneity of pulmonary perfusion during sustained microgravity

    NASA Technical Reports Server (NTRS)

    Prisk, G. Kim; Guy, Harold J. B.; Elliott, Ann R.; West, John B.

    1994-01-01

    The effects of gravity on the inhomogeneity of pulmonary perfusion in man were studied by performing hyperventilation-breathhold single-breath measurements before, during and after 9 days of continuous exposure to microgravity. In microgravity the indicators of inhomogeneity of perfusion, especially the size of cardiogenic oscillations in expired CO2 and the height of phase 4, were both markedly reduced. Cardiogenic oscillations were reduced to approximately 60 of their preflight standing size, while the height of phase 4 was between 0 and -8% (a terminal fall became a small terminal rise) of preflights standing. The terminal change in CO2 was nearly abolished in microgravity indicating more uniformity of blood flow between lung units that close at the end of expiration and units that remain open. This may result from the disappearance of gravity-dependent topographical inequality of blood flow. The residual cardiographic oscillations in expired CO2 imply a persisting inhomogeneity of perfusion in the absence of gravity at a level larger than acinar.

  3. Vascular perfusion in horses with chronic laminitis.

    PubMed

    Hood, D M; Grosenbaugh, D A; Slater, M R

    1994-05-01

    Vascular perfusion casts were used to define and characterise the macroscopic perfusion defects present in the distal digit of 11 horses affected by chronic laminitis. Five clinically normal horses were used as controls. Based on clinical history and clinical status, horses with chronic laminitis were classified as being potentially treatable or clinically refractory. Eleven macroscopic vascular defects were noted in the casts from horses with laminitis. Four types of lesions were identified in the submural laminar circulation, 3 in the coronary bed and 4 were associated with the solar circulation. Multiple defects were present and a definite trend was noted for the perfusion defects to be worse in the casts of clinically refractory subjects than in those considered treatable. This information suggests that evaluation of circulatory status should add significantly to the ability to separate treatable from clinically refractory patients. Results also indicated that ventral displacement of the third phalanx (sinkers) and compression of the solar vasculature are more prevalent than is presently thought.

  4. Dynamic CT perfusion measurement in a cardiac phantom.

    PubMed

    Ziemer, Benjamin P; Hubbard, Logan; Lipinski, Jerry; Molloi, Sabee

    2015-10-01

    Widespread clinical implementation of dynamic CT myocardial perfusion has been hampered by its limited accuracy and high radiation dose. The purpose of this study was to evaluate the accuracy and radiation dose reduction of a dynamic CT myocardial perfusion technique based on first pass analysis (FPA). To test the FPA technique, a pulsatile pump was used to generate known perfusion rates in a range of 0.96-2.49 mL/min/g. All the known perfusion rates were determined using an ultrasonic flow probe and the known mass of the perfusion volume. FPA and maximum slope model (MSM) perfusion rates were measured using volume scans acquired from a 320-slice CT scanner, and then compared to the known perfusion rates. The measured perfusion using FPA (P(FPA)), with two volume scans, and the maximum slope model (P(MSM)) were related to known perfusion (P(K)) by P(FPA) = 0.91P(K) + 0.06 (r = 0.98) and P(MSM) = 0.25P(K) - 0.02 (r = 0.96), respectively. The standard error of estimate for the FPA technique, using two volume scans, and the MSM was 0.14 and 0.30 mL/min/g, respectively. The estimated radiation dose required for the FPA technique with two volume scans and the MSM was 2.6 and 11.7-17.5 mSv, respectively. Therefore, the FPA technique can yield accurate perfusion measurements using as few as two volume scans, corresponding to approximately a factor of four reductions in radiation dose as compared with the currently available MSM. In conclusion, the results of the study indicate that the FPA technique can make accurate dynamic CT perfusion measurements over a range of clinically relevant perfusion rates, while substantially reducing radiation dose, as compared to currently available dynamic CT perfusion techniques.

  5. Feasibility of quantitative lung perfusion by 4D CT imaging by a new dynamic-scanning protocol in an animal model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Goldin, Jonathan G.; Abtin, Fereidoun G.; Brown, Matt; McNitt-Gray, Mike

    2008-03-01

    The purpose of this study is to test a new dynamic Perfusion-CT imaging protocol in an animal model and investigate the feasibility of quantifying perfusion of lung parenchyma to perform functional analysis from 4D CT image data. A novel perfusion-CT protocol was designed with 25 scanning time points: the first at baseline and 24 scans after a bolus injection of contrast material. Post-contrast CT scanning images were acquired with a high sampling rate before the first blood recirculation and then a relatively low sampling rate until 10 minutes after administrating contrast agent. Lower radiation techniques were used to keep the radiation dose to an acceptable level. 2 Yorkshire swine with pulmonary emboli underwent this perfusion- CT protocol at suspended end inspiration. The software tools were designed to measure the quantitative perfusion parameters (perfusion, permeability, relative blood volume, blood flow, wash-in & wash-out enhancement) of voxel or interesting area of lung. The perfusion values were calculated for further lung functional analysis and presented visually as contrast enhancement maps for the volume being examined. The results show increased CT temporal sampling rate provides the feasibility of quantifying lung function and evaluating the pulmonary emboli. Differences between areas with known perfusion defects and those without perfusion defects were observed. In conclusion, the techniques to calculate the lung perfusion on animal model have potential application in human lung functional analysis such as evaluation of functional effects of pulmonary embolism. With further study, these techniques might be applicable in human lung parenchyma characterization and possibly for lung nodule characterization.

  6. Pharmacokinetics of mitomycin C after resection of peritoneal carcinomatosis and intraperitoneal chemohyperthermic perfusion.

    PubMed

    Cerretani, D; Nencini, C; Urso, R; Giorgi, G; Marrelli, D; De Stefano, A; Pinto, E; Cioppa, T; Nastri, G; Roviello, F

    2005-12-01

    Over the last few years surgery on patients with abdominal malignancies has become more aggressive but the majority of patients present locoregional recurrence as peritoneal dissemination. Cytoreductive surgery followed by intraperitoneal chemohyperthermic perfusion (ICHP) has been described for treatment and prevention of locoregional cancer spread from various origins. This paper reports our study of the pharmacokinetics of mitomycin C (MMC) administered by intraperitoneal chemohyperthermic perfusion (ICHP) in patients with peritoneal carcinomatosis. 28 patients received MMC 20 mg/m2 intraperitoneally as a perfusion over 60 min. MMC was determined in perfusate, plasma and urine samples with a UV-HPLC method. A compartmental model was used to fit the drug concentrations in plasma and perfusate. Our results showed a mean maximum plasma concentration (Cmax) of 0.14 +/- 0.086 microg/ml with a peak time (Tmax) of 48..7 +/- 5.61 min. The mean area under the curve (AUC) and terminal half-life (t1/2) were 15.8 +/- 9.8 mg x min/L and 83.7 +/- 31.74 min respectively. Clearance (CL) was estimated by fitting the data by a compartmental model and the mean value was 72 +/- 66 L/h. The percent of the dose absorbed was very variable and ranged between 14 and 57% (mean 37 +/- 14%). The mean percentage of dose recovered unchanged in the urine during 24 hours was 7.21 +/- 3.73%. We conclude that ICHP in patients with peritoneal surface malignancies seems to have clinical value since it gives high peritoneal and tumor MMC concentrations with limited systemic exposure and toxicity.

  7. Perfusion-diffusion mismatch: does it identify who will benefit from reperfusion therapy?

    PubMed

    Powers, William J

    2012-06-01

    A method to determine which patients would benefit from reperfusion therapies after 4.5 h would greatly add to our ability to reduce the disability caused by stroke. The goal of magnetic resonance perfusion-diffusion imaging in hyperacute ischemic stroke is to identify regions of the brain that will die if untreated and will live and regain function if quickly reperfused. The clinical value of perfusion-diffusion imaging in hyperacute ischemic stroke can be proven only by demonstrating empirically in a randomized controlled trial (RCT) that there is an improvement in patient outcome that depends on the use of the neuroimaging modality to guide therapy. To date, there have been only a few RCTs that have evaluated whether perfusion-diffusion imaging can identify a subgroup of patients with ischemic stroke more than 4.5 h from onset in whom the overall benefit from reperfusion therapy outweighs the risk. None have met the rigorous design requirements of the three-group study necessary to adequately test this hypothesis, and none have even met their own criteria for demonstrating a clinical benefit. While studies are not sufficient to conclusively disprove the hypothesis there are no RCT data to support it, and thus, the clinical value of MRI perfusion-diffusion imaging in this setting remains unproven. It is worthy of further investigation in rigorously designed RCTs. However, the risks of symptomatic intracerebral hemorrhage with reperfusion therapies in acute ischemic stroke are proven. Unless RCT data are forthcoming to demonstrate that MRI perfusion-diffusion mismatch improves clinical outcome, it should not be used to guide delayed reperfusion therapy.

  8. Deconvolution-Based CT and MR Brain Perfusion Measurement: Theoretical Model Revisited and Practical Implementation Details.

    PubMed

    Fieselmann, Andreas; Kowarschik, Markus; Ganguly, Arundhuti; Hornegger, Joachim; Fahrig, Rebecca

    2011-01-01

    Deconvolution-based analysis of CT and MR brain perfusion data is widely used in clinical practice and it is still a topic of ongoing research activities. In this paper, we present a comprehensive derivation and explanation of the underlying physiological model for intravascular tracer systems. We also discuss practical details that are needed to properly implement algorithms for perfusion analysis. Our description of the practical computer implementation is focused on the most frequently employed algebraic deconvolution methods based on the singular value decomposition. In particular, we further discuss the need for regularization in order to obtain physiologically reasonable results. We include an overview of relevant preprocessing steps and provide numerous references to the literature. We cover both CT and MR brain perfusion imaging in this paper because they share many common aspects. The combination of both the theoretical as well as the practical aspects of perfusion analysis explicitly emphasizes the simplifications to the underlying physiological model that are necessary in order to apply it to measured data acquired with current CT and MR scanners.

  9. Radiation injury in rat lung: I. Prostacyclin (PGI/sub 2/) production, arterial perfusion, and ultrastructure

    SciTech Connect

    Ts'ao, C.; Ward, W.F.; Port, C.D.

    1983-11-01

    Pulmonary prostacyclin (PGI/sub 2/) production, arterial perfusion, and ultrastructure were correlated in rats sacrificed from 1 day to 6 months after a single exposure of 25 Gy of gamma rays to the right hemithorax. PGI/sub 2/ production by the irradiated lung decreased to approximately half the normal value 1 day after irradiation (P < 0.05), then increased steadily throughout the study. By 6 months postirradiation, the right lung produced two to three times as much PGI/sub 2/ as did either shielded left lung or sham-irradiated lungs (P < 0.05). Perfusion scans revealed hyperemia of the right lung from 1 to 14 days after irradiation. From its peak at 14 days postirradiation, however, perfusion of the irradiated lung decreased steadily, then reached a plateau from 3 to 6 months at less than half that in the shielded left lung. Electron micrographs of the right lung revealed perivascular edema from 1 to 30 days after irradiation. The right lung then exhibited changes typical of radiation pneumonitis followed by progressive interstitial fibrosis. Platelet aggregates were not observed at any time. Thus, decreased PGI/sub 2/ production is an immediate but transient response of the lung to radiation injury. Then from 2 to 6 months after irradiation, the fibrotic, hypoperfused lung produces increasing amounts of the potent vasodilator and antithrombotic agent, PGI/sub 2/. Pulmonary PGI/sub 2/ production and arterial perfusion are inversely correlated for at least 6 months after hemithoracic irradiation.

  10. Changes of perfusion of microvascular free flaps in the head and neck: a prospective clinical study.

    PubMed

    Mücke, Thomas; Rau, Andrea; Merezas, Andreas; Kanatas, Anastasios; Mitchell, David A; Wagenpfeil, Stefan; Wolff, Klaus-Dietrich; Steiner, Timm

    2014-11-01

    Reconstruction with a free flap is routine in head and neck surgery. However, reliable assessment of perfusion can be difficult, so we prospectively evaluated it in 4 types of microvascular free flaps in the oral cavity (n=196) and assessed differences in blood flow by non-invasive monitoring with a laser Doppler flowmetry unit. We measured oxygen saturation, haemoglobin concentration, and velocity on the surface of the flap preoperatively at the donor site, and on the flap on the first, second, and seventh postoperative days, and after 4 weeks in 186/196 patients, mean (SD) age of 60 (13) years. We studied the radial forearm (n=76, 41%), fibular (n=45, 24%), anterolateral thigh (n=53, 28%), and soleus perforator (n=12, 7%) flaps. The values for the radial forearm flap differed significantly from the others. There were significant differences in haemoglobin concentrations between the fibular and soleus perforator flaps, and between the anterolateral thigh and soleus perforator flaps (p=0.002 each). Free flaps are unique in the way that perfusion develops after microvascular anastomoses. Knowledge of how each flap is perfused may indicate different patterns of healing that could potentially influence long term rehabilitation and detection of future deficits in perfusion.

  11. Dose reduction assessment in dynamic CT myocardial perfusion imaging in a porcine balloon-induced-ischemia model

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.

  12. Clock time is absolute and universal

    NASA Astrophysics Data System (ADS)

    Shen, Xinhang

    2015-09-01

    A critical error is found in the Special Theory of Relativity (STR): mixing up the concepts of the STR abstract time of a reference frame and the displayed time of a physical clock, which leads to use the properties of the abstract time to predict time dilation on physical clocks and all other physical processes. Actually, a clock can never directly measure the abstract time, but can only record the result of a physical process during a period of the abstract time such as the number of cycles of oscillation which is the multiplication of the abstract time and the frequency of oscillation. After Lorentz Transformation, the abstract time of a reference frame expands by a factor gamma, but the frequency of a clock decreases by the same factor gamma, and the resulting multiplication i.e. the displayed time of a moving clock remains unchanged. That is, the displayed time of any physical clock is an invariant of Lorentz Transformation. The Lorentz invariance of the displayed times of clocks can further prove within the framework of STR our earth based standard physical time is absolute, universal and independent of inertial reference frames as confirmed by both the physical fact of the universal synchronization of clocks on the GPS satellites and clocks on the earth, and the theoretical existence of the absolute and universal Galilean time in STR which has proved that time dilation and space contraction are pure illusions of STR. The existence of the absolute and universal time in STR has directly denied that the reference frame dependent abstract time of STR is the physical time, and therefore, STR is wrong and all its predictions can never happen in the physical world.

  13. Absolute Radiometric Calibration of EUNIS-06

    NASA Technical Reports Server (NTRS)

    Thomas, R. J.; Rabin, D. M.; Kent, B. J.; Paustian, W.

    2007-01-01

    The Extreme-Ultraviolet Normal-Incidence Spectrometer (EUNIS) is a soundingrocket payload that obtains imaged high-resolution spectra of individual solar features, providing information about the Sun's corona and upper transition region. Shortly after its successful initial flight last year, a complete end-to-end calibration was carried out to determine the instrument's absolute radiometric response over its Longwave bandpass of 300 - 370A. The measurements were done at the Rutherford-Appleton Laboratory (RAL) in England, using the same vacuum facility and EUV radiation source used in the pre-flight calibrations of both SOHO/CDS and Hinode/EIS, as well as in three post-flight calibrations of our SERTS sounding rocket payload, the precursor to EUNIS. The unique radiation source provided by the Physikalisch-Technische Bundesanstalt (PTB) had been calibrated to an absolute accuracy of 7% (l-sigma) at 12 wavelengths covering our bandpass directly against the Berlin electron storage ring BESSY, which is itself a primary radiometric source standard. Scans of the EUNIS aperture were made to determine the instrument's absolute spectral sensitivity to +- 25%, considering all sources of error, and demonstrate that EUNIS-06 was the most sensitive solar E W spectrometer yet flown. The results will be matched against prior calibrations which relied on combining measurements of individual optical components, and on comparisons with theoretically predicted 'insensitive' line ratios. Coordinated observations were made during the EUNIS-06 flight by SOHO/CDS and EIT that will allow re-calibrations of those instruments as well. In addition, future EUNIS flights will provide similar calibration updates for TRACE, Hinode/EIS, and STEREO/SECCHI/EUVI.

  14. Achieving Climate Change Absolute Accuracy in Orbit

    NASA Technical Reports Server (NTRS)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; Bowman, K.; Brindley, H.; Butler, J. J.; Collins, W.; Dykema, J. A.; Doelling, D. R.; Feldman, D. R.; Fox, N.; Huang, X.; Holz, R.; Huang, Y.; Jennings, D.; Jin, Z.; Johnson, D. G.; Jucks, K.; Kato, S.; Kratz, D. P.; Liu, X.; Lukashin, C.; Mannucci, A. J.; Phojanamongkolkij, N.; Roithmayr, C. M.; Sandford, S.; Taylor, P. C.; Xiong, X.

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  15. MO-G-18C-05: Real-Time Prediction in Free-Breathing Perfusion MRI

    SciTech Connect

    Song, H; Liu, W; Ruan, D; Jung, S; Gach, M

    2014-06-15

    Purpose: The aim is to minimize frame-wise difference errors caused by respiratory motion and eliminate the need for breath-holds in magnetic resonance imaging (MRI) sequences with long acquisitions and repeat times (TRs). The technique is being applied to perfusion MRI using arterial spin labeling (ASL). Methods: Respiratory motion prediction (RMP) using navigator echoes was implemented in ASL. A least-square method was used to extract the respiratory motion information from the 1D navigator. A generalized artificial neutral network (ANN) with three layers was developed to simultaneously predict 10 time points forward in time and correct for respiratory motion during MRI acquisition. During the training phase, the parameters of the ANN were optimized to minimize the aggregated prediction error based on acquired navigator data. During realtime prediction, the trained ANN was applied to the most recent estimated displacement trajectory to determine in real-time the amount of spatial Results: The respiratory motion information extracted from the least-square method can accurately represent the navigator profiles, with a normalized chi-square value of 0.037±0.015 across the training phase. During the 60-second training phase, the ANN successfully learned the respiratory motion pattern from the navigator training data. During real-time prediction, the ANN received displacement estimates and predicted the motion in the continuum of a 1.0 s prediction window. The ANN prediction was able to provide corrections for different respiratory states (i.e., inhalation/exhalation) during real-time scanning with a mean absolute error of < 1.8 mm. Conclusion: A new technique enabling free-breathing acquisition during MRI is being developed. A generalized ANN development has demonstrated its efficacy in predicting a continuum of motion profile for volumetric imaging based on navigator inputs. Future work will enhance the robustness of ANN and verify its effectiveness with human

  16. Perfusion MRI: The Five Most Frequently Asked Technical Questions

    PubMed Central

    Essig, Marco; Shiroishi, Mark S.; Nguyen, Thanh Binh; Saake, Marc; Provenzale, James M.; Enterline, David; Anzalone, Nicoletta; Dörfler, Arnd; Rovira, Àlex; Wintermark, Max; Law, Meng

    2013-01-01

    OBJECTIVE This and its companion article address the 10 most frequently asked questions that radiologists face when planning, performing, processing, and interpreting different MR perfusion studies in CNS imaging. CONCLUSION Perfusion MRI is a promising tool in assessing stroke, brain tumors, and patients with neurodegenerative diseases. Most of the impediments that have limited the use of perfusion MRI can be overcome to allow integration of these methods into modern neuroimaging protocols. PMID:23255738

  17. Perfusion Scintigraphy and Patient Selection for Lung Volume Reduction Surgery

    PubMed Central

    Chandra, Divay; Lipson, David A.; Hoffman, Eric A.; Hansen-Flaschen, John; Sciurba, Frank C.; DeCamp, Malcolm M.; Reilly, John J.; Washko, George R.

    2010-01-01

    Rationale: It is unclear if lung perfusion can predict response to lung volume reduction surgery (LVRS). Objectives: To study the role of perfusion scintigraphy in patient selection for LVRS. Methods: We performed an intention-to-treat analysis of 1,045 of 1,218 patients enrolled in the National Emphysema Treatment Trial who were non–high risk for LVRS and had complete perfusion scintigraphy results at baseline. The median follow-up was 6.0 years. Patients were classified as having upper or non–upper lobe–predominant emphysema on visual examination of the chest computed tomography and high or low exercise capacity on cardiopulmonary exercise testing at baseline. Low upper zone perfusion was defined as less than 20% of total lung perfusion distributed to the upper third of both lungs as measured on perfusion scintigraphy. Measurements and Main Results: Among 284 of 1,045 patients with upper lobe–predominant emphysema and low exercise capacity at baseline, the 202 with low upper zone perfusion had lower mortality with LVRS versus medical management (risk ratio [RR], 0.56; P = 0.008) unlike the remaining 82 with high perfusion where mortality was unchanged (RR, 0.97; P = 0.62). Similarly, among 404 of 1,045 patients with upper lobe–predominant emphysema and high exercise capacity, the 278 with low upper zone perfusion had lower mortality with LVRS (RR, 0.70; P = 0.02) unlike the remaining 126 with high perfusion (RR, 1.05; P = 1.00). Among the 357 patients with non–upper lobe–predominant emphysema (75 with low and 282 with high exercise capacity) there was no improvement in survival with LVRS and measurement of upper zone perfusion did not contribute new prognostic information. Conclusions: Compared with optimal medical management, LVRS reduces mortality in patients with upper lobe–predominant emphysema when there is low rather than high perfusion to the upper lung. PMID:20538961

  18. Microvascular Perfusion Changes following Transarterial Hepatic Tumor Embolization

    PubMed Central

    Johnson, Carmen Gacchina; Sharma, Karun V.; Levy, Elliot B.; Woods, David L.; Morris, Aaron H.; Bacher, John D.; Lewis, Andrew L.; Wood, Bradford J.; Dreher, Matthew R.

    2015-01-01

    Purpose To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints. Materials and Methods Rabbit Vx2 liver tumors were embolized with 100–300-µm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint. Tumor microvasculature was labeled with an anti-CD31 antibody and analyzed with fluorescence microscopy for perfusion marker overlap/mismatch. Data were analyzed by analysis of variance and post hoc test (n = 3–5 per group; 18 total). Results Mean microvascular density was 70 vessels/mm2 ± 17 (standard error of the mean), and 81% ± 1 of microvasculature (ie, CD31+ structures) was functionally perfused within viable Vx2 tumor regions. Embolization to the extent of substasis eliminated perfusion in 37% ± 9 of perfused microvessels (P > .05 vs baseline), whereas embolization to the extent of angiographic stasis eliminated perfusion in 56% ± 8 of perfused microvessels. Persistent microvascular perfusion following embolization was predominantly found in the tumor periphery, adjacent to normal tissue. Newly perfused microvasculature was evident following embolization to substasis but not when embolization was performed to complete angiographic stasis. Conclusions Nearly half of tumor microvasculature remained patent despite embolization to complete angiographic stasis. The observed preservation of tumor microvasculature perfusion with angiographic endpoints of substasis and stasis may have implications for tumor response to embolotherapy. PMID:26321051

  19. Measurement of continuous distributions of ventilation-perfusion ratios - Theory

    NASA Technical Reports Server (NTRS)

    Wagner, P. D.; Saltzman, H. A.; West, J. B.

    1974-01-01

    The resolution of the technique considered is sufficient to describe smooth distributions containing blood flow to unventilated regions (shunt), ventilation to unperfused regions (dead space), and up to three additional modes over the range of finite ventilation-perfusion ratios. In particular, areas whose ventilation-perfusion ratios are low can be separated from unventilated regions and those whose ventilation-perfusion ratios are high can similarly be distinguished from unperfused areas.

  20. Scintigraphic perfusion patterns in patients with diffuse lung disease

    SciTech Connect

    Newman, G.E.; Sullivan, D.C.; Gottschalk, A.; Putman, C.E.

    1982-04-01

    Perfusion scintigrams of 55 patients with radiographic evidence of diffuse lung disease were reviewed. Thirty-nine had acute and/or chronic changes caused by congestive heart failure, and 16 had diffuse reticulonodular disease. A normal or near-normal perfusion pattern was seen in 40/55 (73%), and this finding was equally common in the two groups. The authors conclude that perfusion scintigraphy is useful in excluding pulmonary embolism in patients with radiographic evidence of diffuse, symmetrical lung disease.

  1. Brownian motion: Absolute negative particle mobility

    NASA Astrophysics Data System (ADS)

    Ros, Alexandra; Eichhorn, Ralf; Regtmeier, Jan; Duong, Thanh Tu; Reimann, Peter; Anselmetti, Dario

    2005-08-01

    Noise effects in technological applications, far from being a nuisance, can be exploited with advantage - for example, unavoidable thermal fluctuations have found application in the transport and sorting of colloidal particles and biomolecules. Here we use a microfluidic system to demonstrate a paradoxical migration mechanism in which particles always move in a direction opposite to the net acting force (`absolute negative mobility') as a result of an interplay between thermal noise, a periodic and symmetric microstructure, and a biased alternating-current electric field. This counterintuitive phenomenon could be used for bioanalytical purposes, for example in the separation and fractionation of colloids, biological molecules and cells.

  2. Arbitrary segments of absolute negative mobility

    NASA Astrophysics Data System (ADS)

    Chen, Ruyin; Nie, Linru; Chen, Chongyang; Wang, Chaojie

    2017-01-01

    In previous research work, investigators have reported only one or two segments of absolute negative mobility (ANM) in a periodic potential. In fact, many segments of ANM also occur in the system considered here. We investigate transport of an inertial particle in a gating ratchet periodic potential subjected to a constant bias force. Our numerical results show that its mean velocity can decrease with the bias force increasing, i.e. ANM phenomenon. Furthermore, the ANM can take place arbitrary segments, even up to more than thirty. Intrinsic physical mechanism and conditions for arbitrary segments of ANM to occur are discussed in detail.

  3. An absolute radius scale for Saturn's rings

    NASA Technical Reports Server (NTRS)

    Nicholson, Philip D.; Cooke, Maren L.; Pelton, Emily

    1990-01-01

    Radio and stellar occultation observations of Saturn's rings made by the Voyager spacecraft are discussed. The data reveal systematic discrepancies of almost 10 km in some parts of the rings, limiting some of the investigations. A revised solution for Saturn's rotation pole has been proposed which removes the discrepancies between the stellar and radio occultation profiles. Corrections to previously published radii vary from -2 to -10 km for the radio occultation, and +5 to -6 km for the stellar occultation. An examination of spiral density waves in the outer A Ring supports that the revised absolute radii are in error by no more than 2 km.

  4. Absolute Priority for a Vehicle in VANET

    NASA Astrophysics Data System (ADS)

    Shirani, Rostam; Hendessi, Faramarz; Montazeri, Mohammad Ali; Sheikh Zefreh, Mohammad

    In today's world, traffic jams waste hundreds of hours of our life. This causes many researchers try to resolve the problem with the idea of Intelligent Transportation System. For some applications like a travelling ambulance, it is important to reduce delay even for a second. In this paper, we propose a completely infrastructure-less approach for finding shortest path and controlling traffic light to provide absolute priority for an emergency vehicle. We use the idea of vehicular ad-hoc networking to reduce the imposed travelling time. Then, we simulate our proposed protocol and compare it with a centrally controlled traffic light system.

  5. Perfusion lung scanning: differentiation of primary from thromboembolic pulmonary hypertension

    SciTech Connect

    Lisbona, R.; Kreisman, H.; Novales-Diaz, J.; Derbekyan, V.

    1985-01-01

    Of eight patients with pulmonary arterial hypertension, final diagnosis established by autopsy or angiography, four had primary hypertension and four hypertension from thromboembolism. The perfusion lung scan was distinctly different in the two groups. The lung scan in primary pulmonary hypertension was associated with nonsegmental, patchy defects of perfusion, while in thromboembolic hypertensives it was characterized by segmental and/or lobar defects of perfusion with or without subsegmental defects. The perfusion lung scan is a valuable, noninvasive study in the evaluation of the patient with pulmonary hypertension of undetermined cause and in the exclusion of occult large-vessel pulmonary thromboembolism.

  6. New imaging technology: measurement of myocardial perfusion by contrast echocardiography

    NASA Technical Reports Server (NTRS)

    Rubin, D. N.; Thomas, J. D.

    2000-01-01

    Myocardial perfusion imaging has long been a goal for the non-invasive echocardiographic assessment of the heart. However, many factors at play in perfusion imaging have made this goal elusive. Harmonic imaging and triggered imaging with newer contrast agents have made myocardial perfusion imaging potentially practical in the very near future. The application of indicator dilution theory to the coronary circulation and bubble contrast agents is fraught with complexities and sources of error. Therefore, quantification of myocardial perfusion by non-invasive echocardiographic imaging requires further investigation in order to make this technique clinically viable.

  7. Extracorporeal Free Flap Perfusion in Case of Prolonged Ischemia Time.

    PubMed

    Taeger, C D; Präbst, K; Beier, J P; Meyer, A; Horch, R E

    2016-04-01

    In free flap surgery, a clinically established concept still has to be found for the reduction of ischemia-related cell damage in the case of prolonged ischemia. Although promising results using extracorporeal free flap perfusion in the laboratory have been published in the past, until now this concept has not yet paved its way into clinical routine. This might be due to the complexity of perfusion systems and a lack of standardized tools. Here, we want to present the results of the first extracorporeal free flap perfusion in a clinical setting using a simple approach without the application of a complex perfusion machinery.

  8. Absolute counting of neutrophils in whole blood using flow cytometry.

    PubMed

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens.

  9. Absolute Temperature Monitoring Using RF Radiometry in the MRI Scanner

    PubMed Central

    El-Sharkawy, AbdEl-Monem M.; Sotiriadis, Paul P.; Bottomley, Paul A.; Atalar, Ergin

    2007-01-01

    Temperature detection using microwave radiometry has proven value for noninvasively measuring the absolute temperature of tissues inside the body. However, current clinical radiometers operate in the gigahertz range, which limits their depth of penetration. We have designed and built a noninvasive radiometer which operates at radio frequencies (64 MHz) with ∼100-kHz bandwidth, using an external RF loop coil as a thermal detector. The core of the radiometer is an accurate impedance measurement and automatic matching circuit of 0.05 Ω accuracy to compensate for any load variations. The radiometer permits temperature measurements with accuracy of ±0.1°K, over a tested physiological range of 28° C–40° C in saline phantoms whose electric properties match those of tissue. Because 1.5 T magnetic resonance imaging (MRI) scanners also operate at 64 MHz, we demonstrate the feasibility of integrating our radiometer with an MRI scanner to monitor RF power deposition and temperature dosimetry, obtaining coarse, spatially resolved, absolute thermal maps in the physiological range. We conclude that RF radiometry offers promise as a direct, noninvasive method of monitoring tissue heating during MRI studies and thereby providing an independent means of verifying patient-safe operation. Other potential applications include titration of hyper- and hypo-therapies. PMID:18026562

  10. Standardization of the cumulative absolute velocity. Final report

    SciTech Connect

    O`Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ``A Criterion for Determining Exceedance of the Operating Basis Earthquake,`` was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set.

  11. Simulation of absolute amplitudes of ultrasound signals using equivalent circuits.

    PubMed

    Johansson, Jonny; Martinsson, Pär-Erik; Delsing, Jerker

    2007-10-01

    Equivalent circuits for piezoelectric devices and ultrasonic transmission media can be used to cosimulate electronics and ultrasound parts in simulators originally intended for electronics. To achieve efficient system-level optimization, it is important to simulate correct, absolute amplitude of the ultrasound signal in the system, as this determines the requirements on the electronics regarding dynamic range, circuit noise, and power consumption. This paper presents methods to achieve correct, absolute amplitude of an ultrasound signal in a simulation of a pulse-echo system using equivalent circuits. This is achieved by taking into consideration loss due to diffraction and the effect of the cable that connects the electronics and the piezoelectric transducer. The conductive loss in the transmission line that models the propagation media of the ultrasound pulse is used to model the loss due to diffraction. Results show that the simulated amplitude of the echo follows measured values well in both near and far fields, with an offset of about 10%. The use of a coaxial cable introduces inductance and capacitance that affect the amplitude of a received echo. Amplitude variations of 60% were observed when the cable length was varied between 0.07 m and 2.3 m, with simulations predicting similar variations. The high precision in the achieved results show that electronic design and system optimization can rely on system simulations alone. This will simplify the development of integrated electronics aimed at ultrasound systems.

  12. 99mTc-ECD brain perfusion SPECT imaging for the assessment of brain perfusion in cerebral palsy (CP) patients with evaluation of the effect of hyperbaric oxygen therapy

    PubMed Central

    Asl, Mina Taghizadeh; Yousefi, Farzaneh; Nemati, Reza; Assadi, Majid

    2015-01-01

    Objective: The present study was carried out to evaluate cerebral perfusion in different types of cerebral palsy (CP) patients. For those patients who underwent hyperbaric oxygen therapy, brain perfusion before and after the therapy was compared. Methods: A total of 11 CP patients were enrolled in this study, of which 4 patients underwent oxygen therapy. Before oxygen therapy and at the end of 40 sessions of oxygen treatment, 99mTc-ECD brain perfusion single photon emission computed tomography (SPECT) was performed , and the results were compared. Results: A total of 11 CP patients, 7 females and 4 males with an age range of 5-27 years participated in the study. In brain SPECT studies, all the patients showed perfusion impairments. The region most significantly involved was the frontal lobe (54.54%), followed by the temporal lobe (27.27%), the occipital lobe (18.18%), the visual cortex (18.18%), the basal ganglia (9.09%), the parietal lobe (9.09%), and the cerebellum (9.09%). Frontal-lobe hypoperfusion was seen in all types of cerebral palsy. Two out of 4 patients (2 males and 2 females) who underwent oxygen therapy revealed certain degree of brain perfusion improvement. Conclusion: This study demonstrated decreased cerebral perfusion in different types of CP patients. The study also showed that hyperbaric oxygen therapy improved cerebral perfusion in a few CP patients. However, it could keep the physiological discussion open and strenghten a link with other areas of neurology in which this approach may have some value. PMID:25785099

  13. SU-E-I-36: A KWIC and Dirty Look at Dose Savings and Perfusion Metrics in Simulated CT Neuro Perfusion Exams

    SciTech Connect

    Hoffman, J; Martin, T; Young, S; McNitt-Gray, M; Wang, D

    2015-06-15

    Purpose: CT neuro perfusion scans are one of the highest dose exams. Methods to reduce dose include decreasing the number of projections acquired per gantry rotation, however conventional reconstruction of such scans leads to sampling artifacts. In this study we investigated a projection view-sharing reconstruction algorithm used in dynamic MRI – “K-space Weighted Image Contrast” (KWIC) – applied to simulated perfusion exams and evaluated dose savings and impacts on perfusion metrics. Methods: A FORBILD head phantom containing simulated time-varying objects was developed and a set of parallel-beam CT projection data was created. The simulated scans were 60 seconds long, 1152 projections per turn, with a rotation time of one second. No noise was simulated. 5mm, 10mm, and 50mm objects were modeled in the brain. A baseline, “full dose” simulation used all projections and reduced dose cases were simulated by downsampling the number of projections per turn from 1152 to 576 (50% dose), 288 (25% dose), and 144 (12.5% dose). KWIC was further evaluated at 72 projections per rotation (6.25%). One image per second was reconstructed using filtered backprojection (FBP) and KWIC. KWIC reconstructions utilized view cores of 36, 72, 144, and 288 views and 16, 8, 4, and 2 subapertures respectively. From the reconstructed images, time-to-peak (TTP), cerebral blood flow (CBF) and the FWHM of the perfusion curve were calculated and compared against reference values from the full-dose FBP data. Results: TTP, CBF, and the FWHM were unaffected by dose reduction (to 12.5%) and reconstruction method, however image quality was improved when using KWIC. Conclusion: This pilot study suggests that KWIC preserves image quality and perfusion metrics when under-sampling projections and that the unique contrast weighting of KWIC could provided substantial dose-savings for perfusion CT scans. Evaluation of KWIC in clinical CT data will be performed in the near future. R01 EB014922, NCI

  14. CBF and CBV measurements by USPIO bolus tracking: reproducibility and comparison with Gd-based values.

    PubMed

    Simonsen, C Z; Ostergaard, L; Vestergaard-Poulsen, P; Røhl, L; Bjørnerud, A; Gyldensted, C

    1999-02-01

    The authors measured cerebral blood flow (CBF) and cerebral blood volume (CBV) by bolus tracking of a novel ultrasmall superparamagnetic iron oxide (USPIO) contrast agent (NC100150) and compared absolute and relative perfusion measurements with those obtained by a standard gadolinium-based contrast agent. They found a linear correlation between the two methods. A dose of 0.4 mg Fe/kg body weight was found to produce a signal drop similar to that of a standard 0.2 mmol/kg gadodiamide injection using spin-echo echoplanar imaging (SE-EPI) at 1.0 T. The measurements showed a high degree of reproducibility of repeated absolute as well as relative CBF and CBV values, lending further hope to the possibility of using magnetic resonance bolus tracking for routine CBF and CBV measurements. Finally, the authors present their initial experience with high-resolution, non-EPI CBV maps obtained from steady-state levels of an intravascular superparamagnetic contrast agent.

  15. Cerebral perfusion pressure and abnormal intracranial pressure wave forms: their relation to outcome in birth asphyxia.

    PubMed

    Raju, T N; Vidyasagar, D; Papazafiratou, C

    1981-06-01

    Intracranial pressure (ICP) studies were carried out in 14 infants with severe birth asphyxia and brain damage. A markedly low cerebral perfusion pressure (CPP) was noted in infants who died and in 1 infant who survived with cerebral palsy. The long-term ICP tracing revealed negative waves and plateau waves in 2 infants. Cushing response was noted in 2 infants who had elevated ICP. The value and significance of evaluated CPP and of abnormal waveforms are discussed.

  16. Absolute Spectrophotometry of 237 Open Cluster Stars

    NASA Astrophysics Data System (ADS)

    Clampitt, L.; Burstein, D.

    1994-12-01

    We present absolute spectrophotometry of 237 stars in 7 nearby open clusters: Hyades, Pleiades, Alpha Persei, Praesepe, Coma Berenices, IC 4665, and M 39. The observations were taken using the Wampler single-channel scanner (Wampler 1966) on the Crossley 0.9m telescope at Lick Observatory from July 1973 through December 1974. 21 bandpasses spanning the spectral range 3500 Angstroms to 7780 Angstroms were observed for each star, with bandwiths ranging from 32Angstroms to 64 Angstroms. Data are standardized to the Hayes--Latham (1975) system. Our measurements are compared to filter colors on the Johnson BV, Stromgren ubvy, and Geneva U V B_1 B_2 V_1 G systems, as well as to spectrophotometry of a few stars published by Gunn, Stryker & Tinsley and in the Spectrophotometric Standards Catalog (Adelman; as distributed by the NSSDC). Both internal and external comparisons to the filter systems indicate a formal statistical accuracy per bandpass of 0.01 to 0.02 mag, with apparent larger ( ~ 0.03 mag) differences in absolute calibration between this data set and existing spectrophotometry. These data will comprise part of the spectrophotometry that will be used to calibrate the Beijing-Arizona-Taipei-Connecticut Color Survey of the Sky (see separate paper by Burstein et al. at this meeting).

  17. Linear ultrasonic motor for absolute gravimeter.

    PubMed

    Jian, Yue; Yao, Zhiyuan; Silberschmidt, Vadim V

    2017-02-01

    Thanks to their compactness and suitability for vacuum applications, linear ultrasonic motors are considered as substitutes for classical electromagnetic motors as driving elements in absolute gravimeters. Still, their application is prevented by relatively low power output. To overcome this limitation and provide better stability, a V-type linear ultrasonic motor with a new clamping method is proposed for a gravimeter. In this paper, a mechanical model of stators with flexible clamping components is suggested, according to a design criterion for clamps of linear ultrasonic motors. After that, an effect of tangential and normal rigidity of the clamping components on mechanical output is studied. It is followed by discussion of a new clamping method with sufficient tangential rigidity and a capability to facilitate pre-load. Additionally, a prototype of the motor with the proposed clamping method was fabricated and the performance tests in vertical direction were implemented. Experimental results show that the suggested motor has structural stability and high dynamic performance, such as no-load speed of 1.4m/s and maximal thrust of 43N, meeting the requirements for absolute gravimeters.

  18. Why to compare absolute numbers of mitochondria.

    PubMed

    Schmitt, Sabine; Schulz, Sabine; Schropp, Eva-Maria; Eberhagen, Carola; Simmons, Alisha; Beisker, Wolfgang; Aichler, Michaela; Zischka, Hans

    2014-11-01

    Prompted by pronounced structural differences between rat liver and rat hepatocellular carcinoma mitochondria, we suspected these mitochondrial populations to differ massively in their molecular composition. Aiming to reveal these mitochondrial differences, we came across the issue on how to normalize such comparisons and decided to focus on the absolute number of mitochondria. To this end, fluorescently stained mitochondria were quantified by flow cytometry. For rat liver mitochondria, this approach resulted in mitochondrial protein contents comparable to earlier reports using alternative methods. We determined similar protein contents for rat liver, heart and kidney mitochondria. In contrast, however, lower protein contents were determined for rat brain mitochondria and for mitochondria from the rat hepatocellular carcinoma cell line McA 7777. This result challenges mitochondrial comparisons that rely on equal protein amounts as a typical normalization method. Exemplarily, we therefore compared the activity and susceptibility toward inhibition of complex II of rat liver and hepatocellular carcinoma mitochondria and obtained significant discrepancies by either normalizing to protein amount or to absolute mitochondrial number. Importantly, the latter normalization, in contrast to the former, demonstrated a lower complex II activity and higher susceptibility toward inhibition in hepatocellular carcinoma mitochondria compared to liver mitochondria. These findings demonstrate that solely normalizing to protein amount may obscure essential molecular differences between mitochondrial populations.

  19. The absolute threshold of cone vision

    PubMed Central

    Koeing, Darran; Hofer, Heidi

    2013-01-01

    We report measurements of the absolute threshold of cone vision, which has been previously underestimated due to sub-optimal conditions or overly strict subjective response criteria. We avoided these limitations by using optimized stimuli and experimental conditions while having subjects respond within a rating scale framework. Small (1′ fwhm), brief (34 msec), monochromatic (550 nm) stimuli were foveally presented at multiple intensities in dark-adapted retina for 5 subjects. For comparison, 4 subjects underwent similar testing with rod-optimized stimuli. Cone absolute threshold, that is, the minimum light energy for which subjects were just able to detect a visual stimulus with any response criterion, was 203 ± 38 photons at the cornea, ∼0.47 log units lower than previously reported. Two-alternative forced-choice measurements in a subset of subjects yielded consistent results. Cone thresholds were less responsive to criterion changes than rod thresholds, suggesting a limit to the stimulus information recoverable from the cone mosaic in addition to the limit imposed by Poisson noise. Results were consistent with expectations for detection in the face of stimulus uncertainty. We discuss implications of these findings for modeling the first stages of human cone vision and interpreting psychophysical data acquired with adaptive optics at the spatial scale of the receptor mosaic. PMID:21270115

  20. Absolute stereochemistry of altersolanol A and alterporriols.

    PubMed

    Kanamaru, Saki; Honma, Miho; Murakami, Takanori; Tsushima, Taro; Kudo, Shinji; Tanaka, Kazuaki; Nihei, Ken-Ichi; Nehira, Tatsuo; Hashimoto, Masaru

    2012-02-01

    The absolute stereochemistry of altersolanol A (1) was established by observing a positive exciton couplet in the circular dichroism (CD) spectrum of the C3,C4-O-bis(2-naphthoyl) derivative 10 and by chemical correlations with known compound 8. Before the discussion, the relative stereochemistry of 1 was confirmed by X-ray crystallographic analysis. The shielding effect at C7'-OMe group by C1-O-benzoylation established the relative stereochemical relationship between the C8-C8' axial bonding and the C1-C4/C1'-C4' polyol moieties of alterporriols E (3), an atropisomer of the C8-C8' dimer of 1. As 3 could be obtained by dimerization of 1 in vitro, the absolute configuration of its central chirality elements (C1-C4) must be identical to those of 1. Spectral comparison between the experimental and theoretical CD spectra supported the above conclusion. Axial stereochemistry of novel C4-O-deoxy dimeric derivatives, alterporriols F (4) and G (5), were also revealed by comparison of their CD spectra to those of 2 and 3.

  1. Absolute Electron Extraction Efficiency of Liquid Xenon

    NASA Astrophysics Data System (ADS)

    Kamdin, Katayun; Mizrachi, Eli; Morad, James; Sorensen, Peter

    2016-03-01

    Dual phase liquid/gas xenon time projection chambers (TPCs) currently set the world's most sensitive limits on weakly interacting massive particles (WIMPs), a favored dark matter candidate. These detectors rely on extracting electrons from liquid xenon into gaseous xenon, where they produce proportional scintillation. The proportional scintillation from the extracted electrons serves to internally amplify the WIMP signal; even a single extracted electron is detectable. Credible dark matter searches can proceed with electron extraction efficiency (EEE) lower than 100%. However, electrons systematically left at the liquid/gas boundary are a concern. Possible effects include spontaneous single or multi-electron proportional scintillation signals in the gas, or charging of the liquid/gas interface or detector materials. Understanding EEE is consequently a serious concern for this class of rare event search detectors. Previous EEE measurements have mostly been relative, not absolute, assuming efficiency plateaus at 100%. I will present an absolute EEE measurement with a small liquid/gas xenon TPC test bed located at Lawrence Berkeley National Laboratory.

  2. Swarm's Absolute Scalar Magnetometers Burst Mode Results

    NASA Astrophysics Data System (ADS)

    Coisson, P.; Vigneron, P.; Hulot, G.; Crespo Grau, R.; Brocco, L.; Lalanne, X.; Sirol, O.; Leger, J. M.; Jager, T.; Bertrand, F.; Boness, A.; Fratter, I.

    2014-12-01

    Each of the three Swarm satellites embarks an Absolute Scalar Magnetometer (ASM) to provide absolute scalar measurements of the magnetic field with high accuracy and stability. Nominal data acquisition of these ASMs is 1 Hz. But they can also run in a so-called "burst mode" and provide data at 250 Hz. During the commissioning phase of the mission, seven burst mode acquisition campaigns have been run simultaneously for all satellites, obtaining a total of ten days of burs-mode data. These campaigns allowed the identification of issues related to the operations of the piezo-electric motor and the heaters connected to the ASM, that do not impact the nominal 1 Hz scalar data. We analyze the burst mode data to identify high frequency geomagnetic signals, focusing the analysis in two regions: the low latitudes, where we seek signatures of ionospheric irregularities, and the high latitudes, to identify high frequency signals related to polar region currents. Since these campaigns have been conducted during the initial months of the mission, the three satellites where still close to each other, allowing to analyze the spatial coherency of the signals. Wavelet analysis have revealed 31 Hz signals appearing in the night-side in the equatorial region.

  3. Extracting infrared absolute reflectance from relative reflectance measurements.

    PubMed

    Berets, Susan L; Milosevic, Milan

    2012-06-01

    Absolute reflectance measurements are valuable to the optics industry for development of new materials and optical coatings. Yet, absolute reflectance measurements are notoriously difficult to make. In this paper, we investigate the feasibility of extracting the absolute reflectance from a relative reflectance measurement using a reference material with known refractive index.

  4. Albumin modulates S1P delivery from red blood cells in perfused microvessels: mechanism of the protein effect.

    PubMed

    Adamson, R H; Clark, J F; Radeva, M; Kheirolomoom, A; Ferrara, K W; Curry, F E

    2014-04-01

    Removal of plasma proteins from perfusates increases vascular permeability. The common interpretation of the action of albumin is that it forms part of the permeability barrier by electrostatic binding to the endothelial glycocalyx. We tested the alternate hypothesis that removal of perfusate albumin in rat venular microvessels decreased the availability of sphingosine-1-phosphate (S1P), which is normally carried in plasma bound to albumin and lipoproteins and is required to maintain stable baseline endothelial barriers (Am J Physiol Heart Circ Physiol 303: H825-H834, 2012). Red blood cells (RBCs) are a primary source of S1P in the normal circulation. We compared apparent albumin permeability coefficients [solute permeability (Ps)] measured using perfusates containing albumin (10 mg/ml, control) and conditioned by 20-min exposure to rat RBCs with Ps when test perfusates were in RBC-conditioned protein-free Ringer solution. The control perfusate S1P concentration (439 ± 46 nM) was near the normal plasma value at 37 °C and established a stable baseline Ps (0.9 ± 0.4 × 10(-6) cm/s). Ringer solution perfusate contained 52 ± 8 nM S1P and increased Ps more than 10-fold (16.1 ± 3.9 × 10(-6) cm/s). Consistent with albumin-dependent transport of S1P from RBCs, S1P concentrations in RBC-conditioned solutions decreased as albumin concentration, hematocrit, and temperature decreased. Protein-free Ringer solution perfusates that used liposomes instead of RBCs as flow markers failed to maintain normal permeability, reproducing the "albumin effect" in these mammalian microvessels. We conclude that the albumin effect depends on the action of albumin to facilitate the release and transport of S1P from RBCs that normally provide a significant amount of S1P to the endothelium.

  5. [Myocardial perfusion imaging by digital subtraction angiography].

    PubMed

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Alkalinization in the Isolated and Perfused Anterior Midgut of the Larval Mosquito, Aedes aegypti

    PubMed Central

    Onken, Horst; Moffett, Stacia B.; Moffett, David F.

    2008-01-01

    In the present study, isolated midguts of larval Aedes aegypti L. (Diptera: Culicidae) were mounted on perfusion pipettes and bathed in high buffer mosquito saline. With low buffer perfusion saline, containing m-cresol purple, transepithelial voltage was monitored and luminal alkalinization became visible through color changes of m-cresol purple after perfusion stop. Lumen negative voltage and alkalinization depended on metabolic energy and were stimulated in the presence of serotonin (0.2 µmol l-1). In some experiments a pH microelectrode in the lumen recorded pH values up to 10 within minutes after perfusion stop. The V-ATPase inhibitor concanamycin (50 µmol l-1) on the hemolymph side almost abolished Vte and inhibited luminal alkalinization. The carbonic anhydrase inhibitor, methazolamide (50 µmol l-1), on either the luminal or hemolymph-side, or the inhibitor of anion transport, DIDS (1 mmol l-1) on the luminal side, had no effect on Vte or alkalinization. Cl- substitution in the lumen or on both sides of the tissue affected Vte, but the color change of m-cresol purple was unchanged from control conditions. Hemolymph-side Na+ substitution or addition of the Na+/H+ exchange inhibitor, amiloride (200 µmol l-1), reduced Vte and luminal alkalinization. Luminal amiloride (200 µmol l-1) was without effects on Vte or alkalinization. High K+ (60 mmol l-1) in the lumen reduced Vte without affecting alkalinization. These results indicate that strong luminal alkalinization in isolated and perfused anterior midgut of larval A. aegypti depends on basolateral V-ATPase, but is apparently independent of carbonic anhydrase, apical Cl-/HCO3- exchange or apical K+/2H+ antiport. PMID:20307229

  7. Modeling laser speckle imaging of perfusion in the skin (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Regan, Caitlin; Hayakawa, Carole K.; Choi, Bernard

    2016-02-01

    Laser speckle imaging (LSI) enables visualization of relative blood flow and perfusion in the skin. It is frequently applied to monitor treatment of vascular malformations such as port wine stain birthmarks, and measure changes in perfusion due to peripheral vascular disease. We developed a computational Monte Carlo simulation of laser speckle contrast imaging to quantify how tissue optical properties, blood vessel depths and speeds, and tissue perfusion affect speckle contrast values originating from coherent excitation. The simulated tissue geometry consisted of multiple layers to simulate the skin, or incorporated an inclusion such as a vessel or tumor at different depths. Our simulation used a 30x30mm uniform flat light source to optically excite the region of interest in our sample to better mimic wide-field imaging. We used our model to simulate how dynamically scattered photons from a buried blood vessel affect speckle contrast at different lateral distances (0-1mm) away from the vessel, and how these speckle contrast changes vary with depth (0-1mm) and flow speed (0-10mm/s). We applied the model to simulate perfusion in the skin, and observed how different optical properties, such as epidermal melanin concentration (1%-50%) affected speckle contrast. We simulated perfusion during a systolic forearm occlusion and found that contrast decreased by 35% (exposure time = 10ms). Monte Carlo simulations of laser speckle contrast give us a tool to quantify what regions of the skin are probed with laser speckle imaging, and measure how the tissue optical properties and blood flow affect the resulting images.

  8. Vasodilator myocardial perfusion imaging: demonstration of local electrophysiological changes of ischaemia

    PubMed Central

    John, Roy M; Taggart, Peter I; Sutton, Peter M; Costa, Durval C; Ell, Peter J; Swanton, Howard

    1992-01-01

    Objective—To examine the incidence and severity of myocardial ischaemia provoked in the course of perfusion scintigraphy by coronary vasodilators using endocardial recordings of steady state monophasic action potentials as an independent marker of early localised myocardial ischaemia. Patients—31 men undergoing routine cardiac catheterisation for investigation of chest pain were studied. Setting—A tertiary cardiac referral centre. Design—Single site monophasic action potentials were recorded from the left or right ventricle or both (50 recording sites) during intravenous infusion of dipyridamole (0·015 mg/kg/min) for four minutes. Heart rate was held constant with atrial pacing at 20% above the patient's resting rate. Technetium-99m hexakis-2-methoxy-2-methylpropyl-isonitrile (MIBI) was administered four minutes after dipyridamole, and single photon emission tomographic imaging was performed an hour later. Rest images were obtained the next day (two day, two dose protocol). Recordings were divided into three groups based on the scintigraphic perfusion characteristics and coronary anatomical data for the action potential recording site: group 1—recordings from areas with a normal perfusion pattern (n = 30), group 2—recordings from areas with a perfusion defect and subtended by significantly narrowed coronary arteries without obvious angiographic collateral supply (n = 10), and group 3—recordings from areas with a perfusion defect and subtended by occluded arteries with angiographically evident collaterals from adjacent vessels (n = 10). Results—There were changes in the duration of the monophasic action potential indicative of ischaemia—that is, shortening of duration of steady state action potential—in 18 of the 20 recordings from areas of abnormal perfusion. Peak changes were apparent eight minutes from the start of the dipyridamole infusion. Mean (SEM) values for duration of the action potential between control and peak effect at eight

  9. Optimizing cerebral perfusion pressure during fiberoptic bronchoscopy in severe head injury: effect of hyperventilation.

    PubMed

    Previgliano, I J; Ripoll, P I; Chiappero, G; Galíndez, F; Germani, L; González, D H; Ferrari, N; Hlavnicka, A; Purvis, C

    2002-01-01

    The aim of this study was to evaluate if Hyperventilation (HV) could avoid the Intracranial Pressure (ICP) peak that occurs during Fiberoptic Bronchoscopy (FB) in severely head injured patients. A Cerebral Perfusion Pressure (CPP) > 75 mmHg was maintained in 34 patients, with a subgroup randomized to receive controlled HV during FB. Measurements were done before the procedure, during maximum ICP values and 30 minutes after FB. The HV group had minor ICP values after FB, without differences in CPP and ICP peak values.

  10. Absolute measurement of undulator radiation in the extreme ultraviolet

    NASA Astrophysics Data System (ADS)

    Maezawa, H.; Mitani, S.; Suzuki, Y.; Kanamori, H.; Tamamushi, S.; Mikuni, A.; Kitamura, H.; Sasaki, T.

    1983-04-01

    The spectral brightness of undulator radiation emitted by the model PMU-1 incorporated in the SOR-RING, the dedicated synchrotron radiation source in Tokyo, has been studied in the extreme ultraviolet region from 21.6 to 72.9 eV as a function of the electron energy γ, the field parameter K, and the angle of observation ϴ in the absolute scale. A series of measurements covering the first and the second harmonic component of undulator radiation was compared with the fundamental formula λ n= {λ 0}/{2nγ 2}( {1+K 2}/{2}+γϴ 2 and the effects of finite emittance were studied. The brightness at the first peak was smaller than the theoretical value, while an enhanced second harmonic component was observed.

  11. Absolute Radiation Measurements in Earth and Mars Entry Conditions

    NASA Technical Reports Server (NTRS)

    Cruden, Brett A.

    2014-01-01

    This paper reports on the measurement of radiative heating for shock heated flows which simulate conditions for Mars and Earth entries. Radiation measurements are made in NASA Ames' Electric Arc Shock Tube at velocities from 3-15 km/s in mixtures of N2/O2 and CO2/N2/Ar. The technique and limitations of the measurement are summarized in some detail. The absolute measurements will be discussed in regards to spectral features, radiative magnitude and spatiotemporal trends. Via analysis of spectra it is possible to extract properties such as electron density, and rotational, vibrational and electronic temperatures. Relaxation behind the shock is analyzed to determine how these properties relax to equilibrium and are used to validate and refine kinetic models. It is found that, for some conditions, some of these values diverge from non-equilibrium indicating a lack of similarity between the shock tube and free flight conditions. Possible reasons for this are discussed.

  12. Absolute stress measurements at the rangely anticline, Northwestern Colorado

    USGS Publications Warehouse

    de la Cruz, R. V.; Raleigh, C.B.

    1972-01-01

    Five different methods of measuring absolute state of stress in rocks in situ were used at sites near Rangely, Colorado, and the results compared. For near-surface measurements, overcoring of the borehole-deformation gage is the most convenient and rapid means of obtaining reliable values for the magnitude and direction of the state of stress in rocks in situ. The magnitudes and directions of the principal stresses are compared to the geologic features of the different areas of measurement. The in situ stresses are consistent in orientation with the stress direction inferred from the earthquake focal-plane solutions and existing joint patterns but inconsistent with stress directions likely to have produced the Rangely anticline. ?? 1972.

  13. An absolute scale for measuring the utility of money

    NASA Astrophysics Data System (ADS)

    Thomas, P. J.

    2010-07-01

    Measurement of the utility of money is essential in the insurance industry, for prioritising public spending schemes and for the evaluation of decisions on protection systems in high-hazard industries. Up to this time, however, there has been no universally agreed measure for the utility of money, with many utility functions being in common use. In this paper, we shall derive a single family of utility functions, which have risk-aversion as the only free parameter. The fact that they return a utility of zero at their low, reference datum, either the utility of no money or of one unit of money, irrespective of the value of risk-aversion used, qualifies them to be regarded as absolute scales for the utility of money. Evidence of validation for the concept will be offered based on inferential measurements of risk-aversion, using diverse measurement data.

  14. A SOLAR SPECTROSCOPIC ABSOLUTE ABUNDANCE OF ARGON FROM RESIK

    SciTech Connect

    Sylwester, J.; Sylwester, B.; Phillips, K. J. H.; Kuznetsov, V. D. E-mail: kjhp@mssl.ucl.ac.u

    2010-09-10

    Observations of He-like and H-like Ar (Ar XVII and Ar XVIII) lines at 3.949 A and 3.733 A, respectively, with the RESIK X-ray spectrometer on the CORONAS-F spacecraft, together with temperatures and emission measures from the two channels of GOES, have been analyzed to obtain the abundance of Ar in flare plasmas in the solar corona. The line fluxes per unit emission measure show a temperature dependence like that predicted from theory and lead to spectroscopically determined values for the absolute Ar abundance, A(Ar) = 6.44 {+-} 0.07 (Ar XVII) and 6.49 {+-} 0.16 (Ar XVIII), which are in agreement to within uncertainties. The weighted mean is 6.45 {+-} 0.06, which is between two recent compilations of the solar Ar abundance and suggests that the photospheric and coronal abundances of Ar are very similar.

  15. Use of Absolute and Comparative Performance Feedback in Absolute and Comparative Judgments and Decisions

    ERIC Educational Resources Information Center

    Moore, Don A.; Klein, William M. P.

    2008-01-01

    Which matters more--beliefs about absolute ability or ability relative to others? This study set out to compare the effects of such beliefs on satisfaction with performance, self-evaluations, and bets on future performance. In Experiment 1, undergraduate participants were told they had answered 20% correct, 80% correct, or were not given their…

  16. Partial avoidance contingencies: Absolute omission and punishment probabilities1

    PubMed Central

    Flye, Barbaba L.; Gibbon, John

    1979-01-01

    Avoidance contingencies were defined by the absolute probability of the conjunction of responding or not responding with shock or no shock. The “omission” probability (ρ00) is the probability of no response and no shock. The “punishment” probability (ρ11) is the probability of both a response and a shock. The traditional avoidance contingency never omits shock on nonresponse trials (ρ00=0) and never presents shock on response trials (ρ11=0). Rats were trained on a discrete-trial paradigm with no intertrial interval. The first lever response changed an auditory stimulus for the remainder of the trial. Shocks were delivered only at the end of each trial cycle. After initial training under the traditional avoidance contingency, one group of rats experienced changes in omission probability (ρ00>0), holding punishment probability at zero. The second group of rats were studied under different punishment probability values (ρ11>0), holding omission probability at zero. Data from subjects in the omission group looked similar, showing graded decrements in responding with increasing probability of omission. These subjects approximately “matched” their nonresponse frequencies to the programmed probability of shock omission on nonresponse trials, producing a very low and approximately constant conditional probability of shock given no response. Subjects in the punishment group showed different sensitivity to increasing absolute punishment probability. Some subjects decreased responding to low values as punishment probability increased, while others continued to respond at substantial levels even when shock was inevitable on all trials (noncontingent shock schedule). These results confirm an asymmetry between two dimensions of partial avoidance contingencies. When the consequences of not responding included occasional omission of shock, all subjects showed graded sensitivity to changes in omission frequency. When the consequences of responding included

  17. Quantification of nonuniform distribution of hemi-lung perfusion in chronic obstructive pulmonary disease.

    PubMed

    Mitomo, Osamu

    2016-01-01

    Nonuniform distribution (NUD) of perfusion on single photon emission computed tomography (SPECT) is caused by impaired perfusion-related fluctuations of the functional volume (FFV). It was determined if digital analysis of NUD in each hemi-lung damaged by chronic obstructive pulmonary disease (COPD) could improve the whole lung impairment assessment. We examined 665 subjects and 8 controls by SPECT. The basic whole lung SPECT volume was defined at 10% of maximum whole lung count cutoff threshold (T h). For the whole lung and each hemi-lung, the 10% T h width volume, FFV rate, and misfit from the control were calculated at every T h width number (n) from 1 to 9 for every additional 10% T h from 10 to 100%. The misfit value integrated from 1 to 9 of n was defined by 3 NUD indices: D, whole lung NUD index; D rl , the index for the sum of each hemi-lung NUD; and D (I) , the NUD index with every interpolating pattern in which FFV rates of hemi-lungs comprised negative and positive value at the same n. D rl index was the sum of D and D (I) indices in all patients. D rl and D indices significantly increased in pulmonary disease subjects relative to those of the normal group and non-pulmonary disease subjects. D rl and D indices increased in COPD subjects. Progressive COPD subjects had larger D rl index values and "diffuse and even" hemi-lung impairment. The three indices quantizing FFV itself leading to NUD helped to digitally evaluate the degree of lung impairment of perfusion. Clinically, it is expected that the NUD indices and images obtained by SPECT, which visually and digitally show the pathological fluctuations in perfusion caused by lung impairment, will be able to provide specific and useful information for improving treatment and/or care of subjects with COPD.

  18. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

    PubMed

    Salluzzi, M; Frayne, R; Smith, M R

    2006-01-21

    Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies.

  19. Clinical investigation survival prediction in high-grade gliomas by MRI perfusion before and during early stage of RT

    SciTech Connect

    Cao Yue . E-mail: yuecao@med.umich.edu; Tsien, Christina I.; Nagesh, Vijaya; Junck, Larry; Haken, Randall ten; Ross, Brian D.; Chenevert, Thomas L.; Lawrence, Theodore S.

    2006-03-01

    Purpose: To determine whether cerebral blood volume (CBV) and cerebral blood flow can predict the response of high-grade gliomas to radiotherapy (RT) by taking into account spatial heterogeneity and temporal changes in perfusion. Methods and Materials: Twenty-three patients with high-grade gliomas underwent conformal RT, with magnetic resonance imaging perfusion before and at Weeks 1-2 and 3-4 during RT. Tumor perfusion was classified as high, medium, or low. The prognostic values of pre-RT perfusion and the changes during RT for early prediction of tumor response to RT were evaluated. Results: The fractional high-CBV tumor volume before RT and the fluid-attenuated inversion recovery imaging tumor volume were identified as predictors for survival (p = 0.01). Changes in tumor CBV during the early treatment course also predicted for survival. Better survival was predicted by a decrease in the fractional low-CBV tumor volume at Week 1 of RT vs. before RT, a decrease in the fractional high-CBV tumor volume at Week 3 vs. Week 1 of RT, and a smaller pre-RT fluid-attenuated inversion recovery imaging tumor volume (p = 0.01). Conclusion: Early temporal changes during RT in heterogeneous regions of high and low perfusion in gliomas might predict for different physiologic responses to RT. This might also open the opportunity to identify tumor subvolumes that are radioresistant and might benefit from intensified RT.

  20. Glutathione S-transferase iso-enzymes in perfusate from pumped kidneys are associated with delayed graft function.

    PubMed

    Hall, I E; Bhangoo, R S; Reese, P P; Doshi, M D; Weng, F L; Hong, K; Lin, H; Han, G; Hasz, R D; Goldstein, M J; Schröppel, B; Parikh, C R

    2014-04-01

    Accurate and reliable assessment tools are needed in transplantation. The objective of this prospective, multi-center study was to determine the associations of the alpha and pi iso-enzymes of glutathione S-transferase (GST), measured from perfusate solution at the start and end (base and post) of kidney allograft machine perfusion, with subsequent delayed graft function (DGF). We also compared GST iso-enzyme perfusate levels from discarded versus transplanted kidneys. A total of 428 kidneys were linked to outcomes as recorded by the United Network of Organ Sharing. DGF, defined as any dialysis in the first week of transplant, occurred in 141 recipients (32%). Alpha- and pi-GST levels significantly increased during machine perfusion. The adjusted relative risks (95% confidence interval) of DGF with each log-unit increase in base and post pi-GST were 1.14 (1.0-1.3) and 1.36 (1.1-1.8), respectively. Alpha-GST was not independently associated with DGF. There were no significant differences in GST values between discarded and transplanted kidneys, though renal resistance was significantly higher in discarded kidneys. We found pi-GST at the end of machine perfusion to be independently associated with DGF. Further studies should elucidate the utility of GST for identifying injured kidneys with regard to organ allocation, discard and recipient management decisions.

  1. Absolute nonlocality via distributed computing without communication

    NASA Astrophysics Data System (ADS)

    Czekaj, Ł.; Pawłowski, M.; Vértesi, T.; Grudka, A.; Horodecki, M.; Horodecki, R.

    2015-09-01

    Understanding the role that quantum entanglement plays as a resource in various information processing tasks is one of the crucial goals of quantum information theory. Here we propose an alternative perspective for studying quantum entanglement: distributed computation of functions without communication between nodes. To formalize this approach, we propose identity games. Surprisingly, despite no signaling, we obtain that nonlocal quantum strategies beat classical ones in terms of winning probability for identity games originating from certain bipartite and multipartite functions. Moreover we show that, for a majority of functions, access to general nonsignaling resources boosts success probability two times in comparison to classical ones for a number of large enough outputs. Because there are no constraints on the inputs and no processing of the outputs in the identity games, they detect very strong types of correlations: absolute nonlocality.

  2. Determining Absolute Zero Using a Tuning Fork

    NASA Astrophysics Data System (ADS)

    Goldader, Jeffrey D.

    2008-04-01

    The Celsius and Kelvin temperature scales, we tell our students, are related. We explain that a change in temperature of 1°C corresponds to a change of 1 Kelvin and that atoms and molecules have zero kinetic energy at zero Kelvin, -273°C. In this paper, we will show how students can derive the relationship between the Celsius and Kelvin temperature scales using a simple, well-known physics experiment. By making multiple measurements of the speed of sound at different temperatures, using the classic physics experiment of determining the speed of sound with a tuning fork and variable-length tube, they can determine the temperature at which the speed of sound is zero—absolute zero.

  3. MAGSAT: Vector magnetometer absolute sensor alignment determination

    NASA Technical Reports Server (NTRS)

    Acuna, M. H.

    1981-01-01

    A procedure is described for accurately determining the absolute alignment of the magnetic axes of a triaxial magnetometer sensor with respect to an external, fixed, reference coordinate system. The method does not require that the magnetic field vector orientation, as generated by a triaxial calibration coil system, be known to better than a few degrees from its true position, and minimizes the number of positions through which a sensor assembly must be rotated to obtain a solution. Computer simulations show that accuracies of better than 0.4 seconds of arc can be achieved under typical test conditions associated with existing magnetic test facilities. The basic approach is similar in nature to that presented by McPherron and Snare (1978) except that only three sensor positions are required and the system of equations to be solved is considerably simplified. Applications of the method to the case of the MAGSAT Vector Magnetometer are presented and the problems encountered discussed.

  4. An estimate of global absolute dynamic topography

    NASA Technical Reports Server (NTRS)

    Tai, C.-K.; Wunsch, C.

    1984-01-01

    The absolute dynamic topography of the world ocean is estimated from the largest scales to a short-wavelength cutoff of about 6700 km for the period July through September, 1978. The data base consisted of the time-averaged sea-surface topography determined by Seasat and geoid estimates made at the Goddard Space Flight Center. The issues are those of accuracy and resolution. Use of the altimetric surface as a geoid estimate beyond the short-wavelength cutoff reduces the spectral leakage in the estimated dynamic topography from erroneous small-scale geoid estimates without contaminating the low wavenumbers. Comparison of the result with a similarly filtered version of Levitus' (1982) historical average dynamic topography shows good qualitative agreement. There is quantitative disagreement, but it is within the estimated errors of both methods of calculation.

  5. Micron Accurate Absolute Ranging System: Range Extension

    NASA Technical Reports Server (NTRS)

    Smalley, Larry L.; Smith, Kely L.

    1999-01-01

    The purpose of this research is to investigate Fresnel diffraction as a means of obtaining absolute distance measurements with micron or greater accuracy. It is believed that such a system would prove useful to the Next Generation Space Telescope (NGST) as a non-intrusive, non-contact measuring system for use with secondary concentrator station-keeping systems. The present research attempts to validate past experiments and develop ways to apply the phenomena of Fresnel diffraction to micron accurate measurement. This report discusses past research on the phenomena, and the basis of the use Fresnel diffraction distance metrology. The apparatus used in the recent investigations, experimental procedures used, preliminary results are discussed in detail. Continued research and equipment requirements on the extension of the effective range of the Fresnel diffraction systems is also described.

  6. Absolute measurements of fast neutrons using yttrium.

    PubMed

    Roshan, M V; Springham, S V; Rawat, R S; Lee, P; Krishnan, M

    2010-08-01

    Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f(n) approximately 4.1x10(-4) with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10(8) neutrons per discharge.

  7. The pediatric template of brain perfusion

    PubMed Central

    Avants, Brian B; Duda, Jeffrey T; Kilroy, Emily; Krasileva, Kate; Jann, Kay; Kandel, Benjamin T; Tustison, Nicholas J; Yan, Lirong; Jog, Mayank; Smith, Robert; Wang, Yi; Dapretto, Mirella; Wang, Danny J J

    2015-01-01

    Magnetic resonance imaging (MRI) captures the dynamics of brain development with multiple modalities that quantify both structure and function. These measurements may yield valuable insights into the neural patterns that mark healthy maturation or that identify early risk for psychiatric disorder. The Pediatric Template of Brain Perfusion (PTBP) is a free and public neuroimaging resource that will help accelerate the understanding of childhood brain development as seen through the lens of multiple modality neuroimaging and in relation to cognitive and environmental factors. The PTBP uses cross-sectional and longitudinal MRI to quantify cortex, white matter, resting state functional connectivity and brain perfusion, as measured by Arterial Spin Labeling (ASL), in 120 children 7–18 years of age. We describe the PTBP and show, as a demonstration of validity, that global summary measurements capture the trajectories that demarcate critical turning points in brain maturation. This novel resource will allow a more detailed understanding of the network-level, structural and functional landmarks that are obtained during normal adolescent brain development. PMID:25977810

  8. The pediatric template of brain perfusion.

    PubMed

    Avants, Brian B; Duda, Jeffrey T; Kilroy, Emily; Krasileva, Kate; Jann, Kay; Kandel, Benjamin T; Tustison, Nicholas J; Yan, Lirong; Jog, Mayank; Smith, Robert; Wang, Yi; Dapretto, Mirella; Wang, Danny J J

    2015-01-01

    Magnetic resonance imaging (MRI) captures the dynamics of brain development with multiple modalities that quantify both structure and function. These measurements may yield valuable insights into the neural patterns that mark healthy maturation or that identify early risk for psychiatric disorder. The Pediatric Template of Brain Perfusion (PTBP) is a free and public neuroimaging resource that will help accelerate the understanding of childhood brain development as seen through the lens of multiple modality neuroimaging and in relation to cognitive and environmental factors. The PTBP uses cross-sectional and longitudinal MRI to quantify cortex, white matter, resting state functional connectivity and brain perfusion, as measured by Arterial Spin Labeling (ASL), in 120 children 7-18 years of age. We describe the PTBP and show, as a demonstration of validity, that global summary measurements capture the trajectories that demarcate critical turning points in brain maturation. This novel resource will allow a more detailed understanding of the network-level, structural and functional landmarks that are obtained during normal adolescent brain development.

  9. Measured and modelled absolute gravity in Greenland

    NASA Astrophysics Data System (ADS)

    Nielsen, E.; Forsberg, R.; Strykowski, G.

    2012-12-01

    Present day changes in the ice volume in glaciated areas like Greenland will change the load on the Earth and to this change the lithosphere will respond elastically. The Earth also responds to changes in the ice volume over a millennial time scale. This response is due to the viscous properties of the mantle and is known as Glaical Isostatic Adjustment (GIA). Both signals are present in GPS and absolute gravity (AG) measurements and they will give an uncertainty in mass balance estimates calculated from these data types. It is possible to separate the two signals if both gravity and Global Positioning System (GPS) time series are available. DTU Space acquired an A10 absolute gravimeter in 2008. One purpose of this instrument is to establish AG time series in Greenland and the first measurements were conducted in 2009. Since then are 18 different Greenland GPS Network (GNET) stations visited and six of these are visited more then once. The gravity signal consists of three signals; the elastic signal, the viscous signal and the direct attraction from the ice masses. All of these signals can be modelled using various techniques. The viscous signal is modelled by solving the Sea Level Equation with an appropriate ice history and Earth model. The free code SELEN is used for this. The elastic signal is modelled as a convolution of the elastic Greens function for gravity and a model of present day ice mass changes. The direct attraction is the same as the Newtonian attraction and is calculated as this. Here we will present the preliminary results of the AG measurements in Greenland. We will also present modelled estimates of the direct attraction, the elastic and the viscous signals.

  10. Absolute GPS Positioning Using Genetic Algorithms

    NASA Astrophysics Data System (ADS)

    Ramillien, G.

    A new inverse approach for restoring the absolute coordinates of a ground -based station from three or four observed GPS pseudo-ranges is proposed. This stochastic method is based on simulations of natural evolution named genetic algorithms (GA). These iterative procedures provide fairly good and robust estimates of the absolute positions in the Earth's geocentric reference system. For comparison/validation, GA results are compared to the ones obtained using the classical linearized least-square scheme for the determination of the XYZ location proposed by Bancroft (1985) which is strongly limited by the number of available observations (i.e. here, the number of input pseudo-ranges must be four). The r.m.s. accuracy of the non -linear cost function reached by this latter method is typically ~10-4 m2 corresponding to ~300-500-m accuracies for each geocentric coordinate. However, GA can provide more acceptable solutions (r.m.s. errors < 10-5 m2), even when only three instantaneous pseudo-ranges are used, such as a lost of lock during a GPS survey. Tuned GA parameters used in different simulations are N=1000 starting individuals, as well as Pc=60-70% and Pm=30-40% for the crossover probability and mutation rate, respectively. Statistical tests on the ability of GA to recover acceptable coordinates in presence of important levels of noise are made simulating nearly 3000 random samples of erroneous pseudo-ranges. Here, two main sources of measurement errors are considered in the inversion: (1) typical satellite-clock errors and/or 300-metre variance atmospheric delays, and (2) Geometrical Dilution of Precision (GDOP) due to the particular GPS satellite configuration at the time of acquisition. Extracting valuable information and even from low-quality starting range observations, GA offer an interesting alternative for high -precision GPS positioning.

  11. Prolonged cerebral "luxury perfusion" after removal of a convexity meningioma.

    PubMed

    Lunsford, L D; Selker, R G

    1979-04-01

    Following total removal of a convexity meningioma, serial computerized tomographic scans disclosed massive hemispheric contrast enhancement compatible with "luxury perfusion". Maximum enhancement occurred one month following the operation and resolved two months postoperatively. Luxury perfusion appeared to be associated with slowly resolving cerebral edema.

  12. Magnetic Resonance Perfusion Imaging in the Study of Language

    ERIC Educational Resources Information Center

    Hillis, Argye E.

    2007-01-01

    This paper provides a brief review of various uses of magnetic resonance perfusion imaging in the investigation of brain/language relationships. The reviewed studies illustrate how perfusion imaging can reveal areas of brain where dysfunction due to low blood flow is associated with specific language deficits, and where restoration of blood flow…

  13. Perfusion Electronic Record Documentation Using Epic Systems Software.

    PubMed

    Riley, Jeffrey B; Justison, George A

    2015-12-01

    The authors comment on Steffens and Gunser's article describing the University of Wisconsin adoption of the Epic anesthesia record to include perfusion information from the cardiopulmonary bypass patient experience. We highlight the current-day lessons and the valuable quality and safety principles the Wisconsin-Epic model anesthesia-perfusion record provides.

  14. Free flap rescue using an extracorporeal perfusion device.

    PubMed

    Fichter, Andreas M; Ritschl, Lucas M; Rau, Andrea; Schwarzer, Claudia; von Bomhard, Achim; Wagenpfeil, Stefan; Wolff, Klaus-Dietrich; Mücke, Thomas

    2016-12-01

    The warm ischaemia time of microvascular free flaps is limited. Incalculable events, such as lack of adequate recipient vessels or intraoperative medical emergencies, can lead to prolonged ischaemia and potentially to flap loss. In this study, critically perfused ischaemic or congested flaps were temporarily perfused with an extracorporeal perfusion system until anastomosis could be commenced. Temporary extracorporeal perfusion was performed in 8 radial forearm flaps for 147 ± 52 (range 77-237) minutes. Flap perfusion was assessed using Indocyanine Green fluorescence angiography and combined laser Doppler flowmetry and remission spectroscopy. Results were compared with those of 30 patients who underwent conventional reconstruction with radial forearm flaps. Flap survival, flap microcirculation, postoperative complications, and hospital stay did not differ between groups. We report successful free flap transfer after short-term extracorporeal perfusion for up to 4 h in 8 patient cases. Temporary extracorporeal free flap perfusion reduces the warm ischaemia time in emergency situations and can help to prevent flap failure in critically perfused or congested flaps. The trial is registered with ClinicalTrials.gov, number NCT02449525.

  15. Hepatic perfusion abnormalities during CT angiography: Detection and interpretation

    SciTech Connect

    Freeny, P.C.; Marks, W.M.

    1986-06-01

    Twenty-seven perfusion abnormalities were detected in 17 of 50 patients who underwent computed tomographic angiography (CTA) of the liver. All but one of the perfusion abnormalities occurred in patients with primary or metastatic liver tumors. Perfusion abnormalities were lobar in nine cases, segmental in 11, and subsegmental in seven; 14 were hypoperfusion and 13 were hyperperfusion abnormalities. The causes for the abnormalities included nonperfusion of a replaced hepatic artery (n = 11), cirrhosis and nodular regeneration (n = 3), altered hepatic hemodynamics (e.g., siphoning, laminar flow) caused by tumor (n = 7), contrast media washout from a nonperfused vessel (n = 1), compression of adjacent hepatic parenchyma (n = 1), and unknown (n = 4). Differentiation of perfusion abnormalities from tumor usually can be made by comparing the morphology of the known tumor with the suspected perfusion abnormality, changes of each on delayed CTA scans, and review of initial angiograms and other imaging studies.

  16. Automated quantitative analysis of ventilation-perfusion lung scintigrams

    SciTech Connect

    Burton, G.H.; Vernon, P.; Seed, W.A.

    1984-05-01

    An automated computer analysis of ventilation (Kr-81m) and perfusion (Tc-99m) lung images has been devised that produces a graphical image of the distribution of ventilation and perfusion, and of ventilation-perfusion ratios. The analysis has overcome the following problems: the identification of the midline between two lungs and the lung boundaries, the exclusion of extrapulmonary radioactivity, the superimposition of lung images of different sizes, and the format for presentation of the data. Therefore, lung images of different sizes and shapes may be compared with each other. The analysis has been used to develop normal ranges from 55 volunteers. Comparison of younger and older age groups of men and women show small but significant differences in the distribution of ventilation and perfusion, but no differences in ventilation-perfusion ratios.

  17. Impedance plethysmography: a new method for continuous muscle perfusion monitoring.

    PubMed

    Concannon, M J; Stewart, D H; Welsh, C F; Puckett, C L

    1991-08-01

    Vigilant postoperative monitoring of the buried muscle flap is critical after free transfer because early diagnosis of vascular insufficiency is essential to allow prompt correction. We have identified a monitoring method utilizing needle electrodes and impedance plethysmography that gives a beat-to-beat representation of muscular perfusion. In 25 New Zealand White rabbits the gastrocnemius muscle was isolated on its vascular pedicle, and two intramuscular needle electrodes were placed. The instantaneous impedance changes of the muscle (corresponding to the pulsatile volume changes of perfusion) were measured and recorded. Using this representation of perfusion, an independent judge was able to correctly diagnose muscular ischemia 100 percent of the time (n = 25). Further, the judge was able to correctly distinguish the ischemia as arterial (n = 10) or venous (n = 10) in origin 100 percent of the time. Additionally, we monitored muscle perfusion transcutaneously in five free muscle flaps and demonstrated a reliable impedance signal that correlated with perfusion.

  18. Valuing Essays: Essaying Values

    ERIC Educational Resources Information Center

    Badley, Graham

    2010-01-01

    The essay regularly comes under attack. It is criticised for being rigidly linear rather than flexible and reflective. I first challenge this view by examining reasons why the essay should be valued as an important genre. Secondly, I propose that in using the essay form students and academics necessarily exemplify their own critical values. Essays…

  19. Fast perfusion measurements in rat skeletal muscle at rest and during exercise with single-voxel FAIR (flow-sensitive alternating inversion recovery).

    PubMed

    Pohmann, Rolf; Künnecke, Basil; Fingerle, Jürgen; von Kienlin, Markus

    2006-01-01

    Non-invasive measurement of perfusion in skeletal muscle by in vivo magnetic resonance remains a challenge due to its low level and the correspondingly low signal-to-noise ratio. To enable accurate, quantitative, and time-resolved perfusion measurements in the leg muscle, a technique with a high sensitivity is required. By combining a flow-sensitive alternating inversion recovery (FAIR)-sequence with a single-voxel readout, we have developed a new technique to measure the perfusion in the rat gastrocnemius muscle at rest, yielding an average value of 19.4 +/- 4.8 mL/100 g/min (n = 22). In additional experiments, perfusion changes were elicited by acute ischemia and reperfusion or by exercise induced by electrical, noninvasive muscle stimulation with varying duration and intensity. The perfusion time courses during these manipulations were measured with a temporal resolution of 2.2 min, showing increases in perfusion of a factor of up to 2.5. In a direct comparison, the results agreed closely with values found with microsphere measurements in the same animals. The quantitative and noninvasive method can significantly facilitate the investigation of atherosclerotic diseases and the examination of drug efficacy.

  20. Effects of increased heart work on glycolysis and adenine nucleotides in the perfused heart of normal and diabetic rats

    PubMed Central

    Opie, L. H.; Mansford, K. R. L.; Owen, Patricia

    1971-01-01

    1. In the isolated perfused rat heart, the contractile activity and the oxygen uptake were varied by altering the aortic perfusion pressure, or by the atrial perfusion technique (`working heart'). 2. The maximum increase in the contractile activity brought about an eightfold increase in the oxygen uptake. The rate of glycolytic flux rose, while tissue contents of hexose monophosphates, citrate, ATP and creatine phosphate decreased, and contents of ADP and AMP rose. 3. The changes in tissue contents of adenine nucleotides during increased heart work were time-dependent. The ATP content fell temporarily (30s and 2min) after the start of left-atrial perfusion; at 5 and 10min values were normal; and at 30 and 60min values were decreased. ADP and AMP values were increased in the first 15min, but were at control values 30 or 60min after the onset of increased heart work. 4. During increased heart work changes in the tissue contents of adenine nucleotide and of citrate appeared to play a role in altered regulation of glycolysis at the level of phosphofructokinase activity. 5. In recirculation experiments increased heart work for 30min was associated with increased entry of [14C]glucose (11.1mm) and glycogen into glycolysis and a comparable increase in formation of products of glycolysis (lactate, pyruvate and 14CO2). There was no major accumulation of intermediates. Glycogen was not a major fuel for respiration. 6. Increased glycolytic flux in Langendorff perfused and working hearts was obtained by the addition of insulin to the perfusion medium. The concomitant increases in the tissue values of hexose phosphates and of citrate contrasted with the decreased values of hexose monophosphates and of citrate during increased glycolytic flux obtained by increased heart work. 7. Decreased glycolytic flux in Langendorff perfused hearts was obtained by using acute alloxan-diabetic and chronic streptozotocin-diabetic rats; in the latter condition there were decreased tissue

  1. Optical scanning extrinsic Fabry-Perot interferometer for absolute microdisplacement measurement.

    PubMed

    Li, T; May, R G; Wang, A; Claus, R O

    1997-12-01

    We report an optical-scanning, dual-fiber, extrinsic Fabry-Perot interferometer system for absolute measurement of microdisplacement. The system involves two air-gapped Fabry-Perot cavities, formed by fiber end faces, functioning as sensing and reference elements. Taking the scanning wavelength as an interconverter to compare the gap length of the sensing head with the reference-cavity length yields the absolute measurement of the sensing-cavity length. The measurement is independent of the wavelength-scanning accuracy, and the reference-cavity length can be self-calibrated simply by one's changing the sensing-head length by an accurate value.

  2. Absolute quantum cutting efficiency of Tb3+-Yb3+ co-doped glass

    NASA Astrophysics Data System (ADS)

    Duan, Qianqian; Qin, Feng; Zhao, Hua; Zhang, Zhiguo; Cao, Wenwu

    2013-12-01

    The absolute quantum cutting efficiency of Tb3+-Yb3+ co-doped glass was quantitatively measured by an integrating sphere detection system, which is independent of the excitation power. As the Yb3+ concentration increases, the near infrared quantum efficiency exhibited an exponential growth with an upper limit of 13.5%, but the visible light efficiency was reduced rapidly. As a result, the total quantum efficiency monotonically decreases rather than increases as theory predicted. In fact, the absolute quantum efficiency was far less than the theoretical value due to the low radiative efficiency of Tb3+ (<61%) and significant cross-relaxation nonradiative loss between Yb3+ ions.

  3. Using absolute gravimeter data to determine vertical gravity gradients

    USGS Publications Warehouse

    Robertson, D.S.

    2001-01-01

    The position versus time data from a free-fall absolute gravimeter can be used to estimate the vertical gravity gradient in addition to the gravity value itself. Hipkin has reported success in estimating the vertical gradient value using a data set of unusually good quality. This paper explores techniques that may be applicable to a broader class of data that may be contaminated with "system response" errors of larger magnitude than were evident in the data used by Hipkin. This system response function is usually modelled as a sum of exponentially decaying sinusoidal components. The technique employed here involves combining the x0, v0 and g parameters from all the drops made during a site occupation into a single least-squares solution, and including the value of the vertical gradient and the coefficients of system response function in the same solution. The resulting non-linear equations must be solved iteratively and convergence presents some difficulties. Sparse matrix techniques are used to make the least-squares problem computationally tractable.

  4. Absolute Seebeck Coefficient Measurements of Thermoelectric Thin Films

    NASA Astrophysics Data System (ADS)

    Mason, Sarah; Avery, Azure; Basset, Dain; Zink, Barry

    2014-03-01

    Significant advancements in thermoelectric device efficiencies are possible through size reduction to the nanoscale. Quantities that determine a material's efficiency, such as thermopower, or Seebeck coefficient, S, are influenced by the measurement apparatus, so that measuring a thermally generated voltage gives, dV/dT =Ssample -Slead . If accurate values of, Slead, are available, simple subtraction provides Ssample. This is rarely the case in measurements using micromachined devices, with leads exclusively made from thin film materials that do not have well known bulk-like thermopower values. We have developed a technique to directly measure S as a function of T using a micromachined thermal isolation platform consisting of a suspended, patterned SiN membrane. By measuring a series of thicknesses of metallic films up to the infinitely thick thin film limit, in which the thermopower is no longer increasing with thickness, but still not at bulk values, we are able to show the contribution of the leads needed to measure this property. Having a thorough understanding of the background contribution we are able to determine the absolute thermopower of a wide variety of thin films, as well as their thermal and electrical conductivities, on the same sample.

  5. Nifedipine and thallium-201 myocardial perfusion in progressive systemic sclerosis

    SciTech Connect

    Kahan, A.; Devaux, J.Y.; Amor, B.; Menkes, C.J.; Weber, S.; Nitenberg, A.; Venot, A.; Guerin, F.; Degeorges, M.; Roucayrol, J.C.

    1986-05-29

    Heart disease in patients with progressive systemic sclerosis may be due in part to myocardial ischemia caused by a disturbance of the coronary microcirculation. To determine whether abnormalities of myocardial perfusion in this disorder are potentially reversible, we evaluated the effect of the coronary vasodilator nifedipine on myocardial perfusion assessed by thallium-201 scanning in 20 patients. Thallium-201 single-photon-emission computerized tomography was performed under control conditions and 90 minutes after 20 mg of oral nifedipine. The mean (+/- SD) number of left ventricular segments with perfusion defects decreased from 5.3 +/- 2.0 to 3.3 +/- 2.2 after nifedipine (P = 0.0003). Perfusion abnormalities were quantified by a perfusion score (0 to 2.0) assigned to each left ventricular segment and by a global perfusion score (0 to 18) for the entire left ventricle. The mean perfusion score in segments with resting defects increased from 0.97 +/- 0.24 to 1.26 +/- 0.44 after nifedipine (P less than 0.00001). The mean global perfusion score increased from 11.2 +/- 1.7 to 12.8 +/- 2.4 after nifedipine (P = 0.003). The global perfusion score increased by at least 2.0 in 10 patients and decreased by at least 2.0 in only 1. These observations reveal short-term improvement in thallium-201 myocardial perfusion with nifedipine in patients with progressive systemic sclerosis. The results are consistent with a potentially reversible abnormality of coronary vasomotion in this disorder, but the long-term therapeutic effects of nifedipine remain to be determined.

  6. Clinical experience with technetium-99m DTPA aerosol with perfusion scintigraphy in suspected pulmonary embolism

    SciTech Connect

    Selby, J.B.; Gardner, J.J.

    1987-01-01

    To evaluate the clinical value of radioaerosol imaging, 156 patients with suspected pulmonary embolism (PE) were studied. In 25 patients, a preperfusion xenon-133 (Xe-133) study was compared with a postperfusion study using Tc-99m DTPA aerosol. It was found that they were of equal value most of the time (56%), but that the aerosol study was more often helpful. Because of this, and the technical ease of using six standard views with radioaerosol, the series was completed using perfusion scintigraphy followed by radioaerosol images. In 19 patients the perfusion scintigraphy with Tc-99 macroaggregated albumin (Tc-99m MAA) was normal or nearly normal and no aerosol study was required. Tc-99m DTPA aerosol images were satisfactory when the count rate was at least twice and preferably three times that of the previous perfusion study. There were 17 studies (11%) classified as intermediate. There were 26 patients classified as high probability for PE, and angiographic or autopsy correlation was available in 14. All of the 14 proved to have PE. In the 113 patients classified as low probability, there were ten with angiographic or autopsy correlation. In the ten, there was one patient with a small pulmonary embolus found at autopsy. Clinical follow-up for over two months confirmed the absence of PE in the remainder of this group. Aerosol studies have proven technically easier to perform and a satisfactory substitute for xenon imaging in suspected PE.

  7. Myocardial perfusion imaging parameters: IQ-SPECT and conventional SPET system comparison.

    PubMed

    Havel, Martin; Kolacek, Michal; Kaminek, Milan; Dedek, Vladimir; Kraft, Otakar; Sirucek, Pavel

    2014-01-01

    Technological advancement in hardware and software development in myocardial perfusion imaging (MPI) leads to the shortening of acquisition time and reduction of the radiation burden to patients. We compared semiquantitative perfusion results and functional parameters of the left ventricle between new dedicated cardiac system with astigmatic collimators called IQ-SPECT (Siemens Medical Solutions, USA) and conventional single photon emission tomography (SPET) system equipped with standard low energy high resolution collimators. A group of randomly selected 81 patients underwent consecutively the MPI procedure on IQ-SPECT and on conventional SPET systen, both without attenuation correction. The summed scores and the values of the functional parameters of the left ventricle: ejection fraction (EF), end-systolic and end-diastolic volumes (ESV, EDV) received from the automatic analysis software were compared and statistically analyzed. Our results showed that summed scores values were significantly higher for the IQ-SPECT system in comparison to the conventional one. Calculated EF were significantly lower for IQ-SPECT, whereas evaluated left ventricular volumes (LVV) were significantly higher for this system. In conclusion, we recorded significant differences in automatically calculated semiquantitative perfusion and functional parameters when compared uncorrected studies obtained by the IQ-SPECT with the conventional SPET system.

  8. Transport of benzo[alpha]pyrene in the dually perfused human placenta perfusion model: effect of albumin in the perfusion medium.

    PubMed

    Mathiesen, Line; Rytting, Erik; Mose, Tina; Knudsen, Lisbeth E

    2009-09-01

    Transport of benzo[alpha]pyrene (BaP) across the placenta was examined because it is a ubiquitous and highly carcinogenic substance found in tobacco smoke, polluted air and certain foods. Foetal exposure to this substance is highly relevant but is difficult to estimate. The human placenta is unique compared to other species; since it is available without major ethical obstacles, we have used the human placenta perfusion model to study transport from mother to foetus. Placentas were donated after births at Rigshospitalet in Copenhagen from pregnant mothers who signed an informed consent. BaP is lipophilic and studies using cell culture medium in 6-hr placenta perfusions showed minimal transport through the placenta. To increase the solubility of BaP in perfusion medium and to increase physiological relevance, perfusions were also performed with albumin added to the perfusion medium [2 and 30 mg/ml bovine serum albumin (BSA) and 30 mg/ml human serum albumin (HSA)]. The addition of albumin resulted in increased transfer of BaP from maternal to foetal reservoirs. The transfer was even higher in the presence of an HSA formulation containing acetyltryptophanate and caprylate, resulting in a foetal-maternal concentration (FM) ratio of 0.71 +/- 0.10 after 3 hr and 0.78 +/- 0.11 after 6 hr, whereas the FM ratio in perfusions without albumin was only 0.05 +/- 0.03 after 6 hr of perfusion. Less BaP accumulated in placental tissue in perfusions with added albumin. This shows that transplacental transport of the pro-carcinogenic substance BaP occurs, and emphasizes the importance of adding physiological concentrations of albumin when studying the transport of lipophilic substances.

  9. Contrast enhanced ultrasound with quantitative perfusion analysis for objective characterization of pancreatic ductal adenocarcinoma: A feasibility study.

    PubMed

    D'Onofrio, Mirko; Canestrini, Stefano; Crosara, Stefano; De Robertis, Riccardo; Pozzi Mucelli, Roberto

    2014-03-28

    The aim of this study was to determine whether contrast enhanced ultrasound (CEUS) quantitative perfusion analysis allows an objective characterization of ductal adenocarcinoma (ADK) of the pancreas. Patients with pancreatic ADK underwent CEUS. All examinations were performed on an Acuson S2000 system (Siemens, Erlangen, Germany) after the iv administration of 2.4 mL contrast agent (SonoVue(®), Bracco, Milan, Italy). All lesions were pathologically proved. An operator manually drew different regions of interest within the tumor and the adjacent parenchyma to allow the quantitative perfusion analysis. The mean values of peak of enhancement, time to peak and ascending curve were calculated and compared using the Student's t test. The quantitative perfusion analysis was possible in all lesions. The mean values of the peak of enhancement, time to peak and ascending curve were 17.19%, 7.97 s and 159.52% s within the tumor and 33.57%, 8.89 s and 355.29% s within the adjacent parenchyma. The peak of enhancement and the ascending curve values were significantly different within the tumor and the adjacent parenchyma. Thus, CEUS allows the quantitative perfusion analysis of pancreatic ductal adenocarcinoma.

  10. Quantitative Perfusion and Permeability Biomarkers in Brain Cancer from Tomographic CT and MR Images

    PubMed Central

    Eilaghi, Armin; Yeung, Timothy; d’Esterre, Christopher; Bauman, Glenn; Yartsev, Slav; Easaw, Jay; Fainardi, Enrico; Lee, Ting-Yim; Frayne, Richard

    2016-01-01

    Dynamic contrast-enhanced perfusion and permeability imaging, using computed tomography and magnetic resonance systems, are important techniques for assessing the vascular supply and hemodynamics of healthy brain parenchyma and tumors. These techniques can measure blood flow, blood volume, and blood–brain barrier permeability surface area product and, thus, may provide information complementary to clinical and pathological assessments. These have been used as biomarkers to enhance the treatment planning process, to optimize treatment decision-making, and to enable monitoring of the treatment noninvasively. In this review, the principles of magnetic resonance and computed tomography dynamic contrast-enhanced perfusion and permeability imaging are described (with an emphasis on their commonalities), and the potential values of these techniques for differentiating high-grade gliomas from other brain lesions, distinguishing true progression from posttreatment effects, and predicting survival after radiotherapy, chemotherapy, and antiangiogenic treatments are presented. PMID:27398030

  11. [Evaluation of circulatory state using pulse oximeter: 2. PI (perfusion index) x PVI (pleth variability index)].

    PubMed

    Kaneda, Toru; Suzuki, Toshiyasu

    2009-07-01

    Pulse oximeter expressed by SpO2 is used for monitoring respiratory state during operation and in ICU. Perfusion index (PI) and pleth variability index (PVI) as new indexes are calculated from pulse oximeter (Masimo SET Radical-7, Masimo Corp., USA, 1998) waveforms. And these indices were used as parameters to evaluate the circulatory state. For PI calculation, the pulsatile infrared signal is indexed against the nonpulsatile infrared signal and expressed as a percentage. It might thus be of future value in assessment of perioperative changes in peripheral perfusion. PVI is a measure of a dynamic change in PI that occurs during complete respiratory cycle. It might be thought that PVI, an index automatically derived from the pulse oximeter waveform analysis, had potentially clinical applications for noninvasive hypovolemia detection and fluid responsiveness monitoring.

  12. "Absolute" quantification in magnetic resonance spectroscopy: validation of a clinical protocol in multiple sclerosis.

    PubMed

    Bagory, Matthieu; Durand-Dubief, Françoise; Ibarrola, Danielle; Confavreux, Christian; Sappey-Marinier, Dominique

    2007-01-01

    MRS allows to measure cerebral metabolites, thus helping to characterize brain disease diagnosis and followup. Metabolite concentration quantification is usually based on metabolite ratio referring to creatine. If this metabolite concentration is supposed to be constant, it may vary in pathological processes. Therefore, "absolute" concentration methodology is needed. The aim of this study is to validate a clinical "absolute" quantification protocol through the development of an external metabolic phantom, calibration and correction, and the investigation of reproducibility issues. When phantom stability was investigated by a short-term and a long-term reproducibility study, both Standard Deviations (SD) were in agreement with literature values. This "absolute" quantification method was applied to patients with Multiple Sclerosis (MS). The results show a significant decrease in both N-Acetyl Aspartate (NAA) and choline concentrations.

  13. STANDARDIZING TYPE Ia SUPERNOVA ABSOLUTE MAGNITUDES USING GAUSSIAN PROCESS DATA REGRESSION

    SciTech Connect

    Kim, A. G.; Aldering, G.; Aragon, C.; Bailey, S.; Childress, M.; Fakhouri, H. K.; Nordin, J.; Thomas, R. C.; Antilogus, P.; Bongard, S.; Canto, A.; Cellier-Holzem, F.; Guy, J.; Baltay, C.; Buton, C.; Kerschhaggl, M.; Kowalski, M.; Chotard, N.; Copin, Y.; Gangler, E.; and others

    2013-04-01

    We present a novel class of models for Type Ia supernova time-evolving spectral energy distributions (SEDs) and absolute magnitudes: they are each modeled as stochastic functions described by Gaussian processes. The values of the SED and absolute magnitudes are defined through well-defined regression prescriptions, so that data directly inform the models. As a proof of concept, we implement a model for synthetic photometry built from the spectrophotometric time series from the Nearby Supernova Factory. Absolute magnitudes at peak B brightness are calibrated to 0.13 mag in the g band and to as low as 0.09 mag in the z = 0.25 blueshifted i band, where the dispersion includes contributions from measurement uncertainties and peculiar velocities. The methodology can be applied to spectrophotometric time series of supernovae that span a range of redshifts to simultaneously standardize supernovae together with fitting cosmological parameters.

  14. An integrated model of choices and response times in absolute identification.

    PubMed

    Brown, Scott D; Marley, A A J; Donkin, Christopher; Heathcote, Andrew

    2008-04-01

    Recent theoretical developments in the field of absolute identification have stressed differences between relative and absolute processes, that is, whether stimulus magnitudes are judged relative to a shorter term context provided by recently presented stimuli or a longer term context provided by the entire set of stimuli. The authors developed a model (SAMBA: selective attention, mapping, and ballistic accumulation) that integrates shorter and longer term memory processes and accounts for both the choices made and the associated response time distributions, including sequential effects in each. The model's predictions arise as a consequence of its architecture and require estimation of only a few parameters with values that are consistent across numerous data sets. The authors show that SAMBA provides a quantitative account of benchmark choice phenomena in classical absolute identification experiments and in contemporary data involving both choice and response time.

  15. Absolute Binding Energies of Core Levels in Solids from First Principles

    NASA Astrophysics Data System (ADS)

    Ozaki, Taisuke; Lee, Chi-Cheng

    2017-01-01

    A general method is presented to calculate absolute binding energies of core levels in metals and insulators, based on a penalty functional and an exact Coulomb cutoff method in the framework of density functional theory. The spurious interaction of core holes between supercells is avoided by the exact Coulomb cutoff method, while the variational penalty functional enables us to treat multiple splittings due to chemical shift, spin-orbit coupling, and exchange interaction on equal footing, both of which are not accessible by previous methods. It is demonstrated that the absolute binding energies of core levels for both metals and insulators are calculated by the proposed method in a mean absolute (relative) error of 0.4 eV (0.16%) for eight cases compared to experimental values measured with x-ray photoemission spectroscopy within a generalized gradient approximation to the exchange-correlation functional.

  16. Convective-to-absolute instability transition in a viscoelastic capillary jet subject to unrelaxed axial elastic tension.

    PubMed

    Mohamed, A Said; Herrada, M A; Gañán-Calvo, A M; Montanero, J M

    2015-08-01

    The convective-to-absolute instability transition in an Oldroyd-B capillary jet subject to unrelaxed axial stress is examined theoretically. There is a critical Weber number below which the jet is absolutely unstable under axisymmetric perturbations. We analyze the dependence of this critical parameter with respect to the Reynolds and Deborah numbers, as well as the unrelaxed axial stress. For small Deborah numbers, the unrelaxed stress destabilizes the viscoelastic jet, increasing the critical Weber number for which the convective-to-absolute instability transition takes place. If the Deborah number takes higher values, then the transitional Weber number decreases as the unrelaxed stress increases until two solution branches cross each other. The dominant branch for large axial stress leads to a threshold of this quantity above which the viscoelastic jet becomes absolutely unstable independently of the Weber number. The threshold depends on neither the Reynolds nor the Deborah number for sufficiently large values of these parameters.

  17. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging

    PubMed Central

    Martin, Alastair J.; Alexander, Matthew D.; McCoy, David B.; Cooke, Daniel L.; Lillaney, Prasheel; Moftakhar, Parham; Amans, Matthew R.; Settecase, Fabio; Nicholson, Andrew; Dowd, Christopher F.; Halbach, Van V.; Higashida, Randall T.; McDermott, Michael W.; Saloner, David; Hetts, Steven W.

    2016-01-01

    Background and Purpose To evaluate the ability of IA MR perfusion to characterize meningioma blood supply. Methods Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA) and intravenous (IV) T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA) dural, internal carotid artery (ICA) dural, or pial. MR perfusion data regions of interest (ROIs) were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM), relative cerebral blood flow (rCBF), relative cerebral blood volume (rCBV), and mean transit time (MTT). Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling. Results 18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11), ICA dural (n = 4), or pial (n = 3). FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion. PMID:27802268

  18. Neutrophil gelatinase-associated lipocalin, a new biomarker candidate in perfusate of machine-perfused kidneys: a porcine pilot experiment.

    PubMed

    Jochmans, I; Monbaliu, D; Pirenne, J

    2011-11-01

    The enduring kidney graft shortage has led to the increasing use of expanded-criteria donors as well as kidneys donated after cardiac death, triggering the revival of machine perfusion preservation. Indeed, machine perfusion not only preserves these kidneys better than static cold storage, but also has the potential to evaluate them. The presence of certain biomarkers, among them aspartate aminotransferase (AST) and heart-type fatty acid binding protein (H-FABP), has been demonstrated in the perfusate of human kidneys, making them potentially useful as biomarkers of graft quality. Neutrophil gelatinase-associated lipocalin (NGAL) which is believed to be released upon renal tubular cell injury is another biomarker candidate. However, because it is also released from neutrophils, it is currently unclear whether NGAL is a direct or indirect, inflammatory-mediated marker of kidney injury. To resolve this issue we established a pilot experiment to study the concentrations of AST, H-FABP, and NGAL in the perfusates of 6 porcine kidneys that were exposed to incremental periods of warm ischemia before machine perfusion for 22 hours. An ex vivo porcine model was chosen because preclinical large animal work remains necessary to refine machine perfusion technology and because the presence of these markers in perfusates of porcine kidneys had not been shown previously. All 3 biomarkers were detectable in the cold acellular perfusate; their release seemed to be proportionate to the degree of warm injury, albeit that this must be confirmed in a larger sample. In conclusion, NGAL is directly released by ischemically damaged kidneys, independent of neutrophil activation. In addition to NGAL, the determination of AST and H-FABP in perfusates of machine-perfused porcine kidneys is also feasible. Determination of these markers may be added to the arsenal of research tools for preclinical preservation research.

  19. Evaluation of Perfusion Quantification Methods with Ultrasound Contrast Agents in a Machine-Perfused Pig Liver.

    PubMed

    Averkiou, M; Keravnou, C P; Izamis, M L; Leen, E

    2016-05-03

    Purpose: To evaluate dynamic contrast-enhanced ultrasound (DCEUS) as a tool for measuring blood flow in the macro- and microcirculation of an ex-vivo machine-perfused pig liver and to confirm the ability of DCEUS to accurately detect induced flow rate changes so that it could then be used clinically for monitoring flow changes in liver tumors. Materials and Methods: Bolus injections of contrast agents in the hepatic artery (HA) and portal vein (PV) were administered to 3 machine-perfused pig livers. Flow changes were induced by the pump of the machine perfusion system. The induced flow rates were of clinical relevance (150 - 400 ml/min for HA and 400 - 1400 ml/min for PV). Quantification parameters from time-intensity curves [rise time (RT), mean transit time (MTT), area under the curve (AUC) and peak intensity (PI)] were extracted in order to evaluate whether the induced flow changes were reflected in these parameters. Results: A linear relationship between the image intensity and the microbubble concentration was confirmed first, while time parameters (RT and MMT) were found to be independent of concentration. The induced flow changes which propagated from the larger vessels to the parenchyma were reflected in the quantification parameters. Specifically, RT, MTT and AUC correlated with flow rate changes. Conclusion Machine-perfused pig liver is an excellent test bed for DCEUS quantification approaches for the study of the hepatic vascular networks. DCEUS quantification parameters (RT, MTT, and AUC) can measure relative flow changes of about 20 % and above in the liver vasculature. DCEUS quantification is a promising tool for real-time monitoring of the vascular network of tumors.

  20. Antiausterity activity of arctigenin enantiomers: importance of (2R,3R)-absolute configuration.

    PubMed

    Awale, Suresh; Kato, Mamoru; Dibwe, Dya Fita; Li, Feng; Miyoshi, Chika; Esumi, Hiroyasu; Kadota, Shigetoshi; Tezuka, Yasuhiro

    2014-01-01

    From a MeOH extract of powdered roots of Wikstroemia indica, six dibenzyl-gamma-butyrolactone-type lignans with (2S,3S)-absolute configuration [(+)-arctigenin (1), (+)-matairesinol (2), (+)-trachelogenin (3), (+)-nortrachelogenin (4), (+)-hinokinin (5), and (+)-kusunokinin (6)] were isolated, whereas three dibenzyl-gamma-butyrolactone-type lignans with (2R,3R)-absolute configuration [(-)-arctigenin (1*), (-)-matairesinol (2*), (-)-trachelogenin (3*)] were isolated from Trachelospermum asiaticum. The in vitro preferential cytotoxic activity of the nine compounds was evaluated against human pancreatic PANC-1 cancer cells in nutrient-deprived medium (NDM), but none of the six lignans (1-6) with (2S,3S)-absolute configuration showed preferential cytotoxicity. On the other hand, three lignans (1*-3*) with (2R,3R)-absolute configuration exhibited preferential cytotoxicity in a concentration-dependent manner with PC50 values of 0.54, 6.82, and 5.85 microM, respectively. Furthermore, the effect of (-)- and (+)-arctigenin was evaluated against the activation of Akt, which is a key process in the tolerance to nutrition starvation. Interestingly, only (-)-arctigenin (1*) strongly suppressed the activation of Akt. These results indicate that the (2R,3R)-absolute configuration of (-)-enantiomers should be required for the preferential cytotoxicity through the inhibition of Akt activation.

  1. Utilizing a reference material for assessing absolute tumor mechanical properties in modality independent elastography

    NASA Astrophysics Data System (ADS)

    Kim, Dong Kyu; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    There is currently no reliable method for early characterization of breast cancer response to neoadjuvant chemotherapy (NAC) [1,2]. Given that disruption of normal structural architecture occurs in cancer-bearing tissue, we hypothesize that further structural changes occur in response to NAC. Consequently, we are investigating the use of modalityindependent elastography (MIE) [3-8] as a method for monitoring mechanical integrity to predict long term outcomes in NAC. Recently, we have utilized a Demons non-rigid image registration method that allows 3D elasticity reconstruction in abnormal tissue geometries, making it particularly amenable to the evaluation of breast cancer mechanical properties. While past work has reflected relative elasticity contrast ratios [3], this study improves upon that work by utilizing a known stiffness reference material within the reconstruction framework such that a stiffness map becomes an absolute measure. To test, a polyvinyl alcohol (PVA) cryogel phantom and a silicone rubber mock mouse tumor phantom were constructed with varying mechanical stiffness. Results showed that an absolute measure of stiffness could be obtained based on a reference value. This reference technique demonstrates the ability to generate accurate measurements of absolute stiffness to characterize response to NAC. These results support that `referenced MIE' has the potential to reliably differentiate absolute tumor stiffness with significant contrast from that of surrounding tissue. The use of referenced MIE to obtain absolute quantification of biomarkers is also translatable across length scales such that the characterization method is mechanics-consistent at the small animal and human application.

  2. Measuring perfusion with light (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Jansen, Sanne M. A.; de Bruin, Daniel M.; Faber, Dirk J.; van Leeuwen, Ton G.

    2016-03-01

    There is no gold standard test for perfusion evaluation in surgery. Optical Imaging techniques are able to image tissue at high resolution and in real-time. Laser Speckle Contrast Imaging, Optical Coherence Tomography, Sidestream Darkfield and Incident Darkfield all use the interaction of light with tissue to create an image. To test their feasibility and explore validity in a controlled setting, we created a phantom with the optical properties of tissue and microvascular channels of 30-400 micrometer. With a Hamilton Syringe Pump we mimicked blood flow velocities of 0-20 mm/sec. Images of all different modalities at different blood flow velocities were compared in terms of imaging depth, resoluation and hemodynamic parameters.

  3. Hydrogels for Engineering of Perfusable Vascular Networks.

    PubMed

    Liu, Juan; Zheng, Huaiyuan; Poh, Patrina S P; Machens, Hans-Günther; Schilling, Arndt F

    2015-07-14

    Hydrogels are commonly used biomaterials for tissue engineering. With their high-water content, good biocompatibility and biodegradability they resemble the natural extracellular environment and have been widely used as scaffolds for 3D cell culture and studies of cell biology. The possible size of such hydrogel constructs with embedded cells is limited by the cellular demand for oxygen and nutrients. For the fabrication of large and complex tissue constructs, vascular structures become necessary within the hydrogels to supply the encapsulated cells. In this review, we discuss the types of hydrogels that are currently used for the fabrication of constructs with embedded vascular networks, the key properties of hydrogels needed for this purpose and current techniques to engineer perfusable vascular structures into these hydrogels. We then discuss directions for future research aimed at engineering of vascularized tissue for implantation.

  4. Hydrogels for Engineering of Perfusable Vascular Networks

    PubMed Central

    Liu, Juan; Zheng, Huaiyuan; Poh, Patrina S. P.; Machens, Hans-Günther; Schilling, Arndt F.

    2015-01-01

    Hydrogels are commonly used biomaterials for tissue engineering. With their high-water content, good biocompatibility and biodegradability they resemble the natural extracellular environment and have been widely used as scaffolds for 3D cell culture and studies of cell biology. The possible size of such hydrogel constructs with embedded cells is limited by the cellular demand for oxygen and nutrients. For the fabrication of large and complex tissue constructs, vascular structures become necessary within the hydrogels to supply the encapsulated cells. In this review, we discuss the types of hydrogels that are currently used for the fabrication of constructs with embedded vascular networks, the key properties of hydrogels needed for this purpose and current techniques to engineer perfusable vascular structures into these hydrogels. We then discuss directions for future research aimed at engineering of vascularized tissue for implantation. PMID:26184185

  5. Adenosine thallium 201 myocardial perfusion scintigraphy

    SciTech Connect

    Verani, M.S. )

    1991-07-01

    Pharmacologic coronary vasodilation as an adjunct to myocardial perfusion imaging has become increasingly important in the evaluation of patients with coronary artery disease, in view of the large number of patients who cannot perform an adequate exercise test or in whom contraindications render exercise inappropriate. Adenosine is a very potent coronary vasodilator and when combined with thallium 201 scintigraphy produces images of high quality, with the added advantages of a very short half-life (less than 10 seconds) and the ability to adjust the dose during the infusion, which may enhance safety and curtail the duration of side effects. The reported sensitivity and specificity of adenosine thallium 201 scintigraphy for the detection of coronary artery disease are high and at least comparable with imaging after exercise or dipyridamole administration. 23 refs.

  6. Absolute calibration of forces in optical tweezers

    NASA Astrophysics Data System (ADS)

    Dutra, R. S.; Viana, N. B.; Maia Neto, P. A.; Nussenzveig, H. M.

    2014-07-01

    Optical tweezers are highly versatile laser traps for neutral microparticles, with fundamental applications in physics and in single molecule cell biology. Force measurements are performed by converting the stiffness response to displacement of trapped transparent microspheres, employed as force transducers. Usually, calibration is indirect, by comparison with fluid drag forces. This can lead to discrepancies by sizable factors. Progress achieved in a program aiming at absolute calibration, conducted over the past 15 years, is briefly reviewed. Here we overcome its last major obstacle, a theoretical overestimation of the peak stiffness, within the most employed range for applications, and we perform experimental validation. The discrepancy is traced to the effect of primary aberrations of the optical system, which are now included in the theory. All required experimental parameters are readily accessible. Astigmatism, the dominant effect, is measured by analyzing reflected images of the focused laser spot, adapting frequently employed video microscopy techniques. Combined with interface spherical aberration, it reveals a previously unknown window of instability for trapping. Comparison with experimental data leads to an overall agreement within error bars, with no fitting, for a broad range of microsphere radii, from the Rayleigh regime to the ray optics one, for different polarizations and trapping heights, including all commonly employed parameter domains. Besides signaling full first-principles theoretical understanding of optical tweezers operation, the results may lead to improved instrument design and control over experiments, as well as to an extended domain of applicability, allowing reliable force measurements, in principle, from femtonewtons to nanonewtons.

  7. Elevation correction factor for absolute pressure measurements

    NASA Technical Reports Server (NTRS)

    Panek, Joseph W.; Sorrells, Mark R.

    1996-01-01

    With the arrival of highly accurate multi-port pressure measurement systems, conditions that previously did not affect overall system accuracy must now be scrutinized closely. Errors caused by elevation differences between pressure sensing elements and model pressure taps can be quantified and corrected. With multi-port pressure measurement systems, the sensing elements are connected to pressure taps that may be many feet away. The measurement system may be at a different elevation than the pressure taps due to laboratory space or test article constraints. This difference produces a pressure gradient that is inversely proportional to height within the interface tube. The pressure at the bottom of the tube will be higher than the pressure at the top due to the weight of the tube's column of air. Tubes with higher pressures will exhibit larger absolute errors due to the higher air density. The above effect is well documented but has generally been taken into account with large elevations only. With error analysis techniques, the loss in accuracy from elevation can be easily quantified. Correction factors can be applied to maintain the high accuracies of new pressure measurement systems.

  8. Gyrokinetic Statistical Absolute Equilibrium and Turbulence

    SciTech Connect

    Jian-Zhou Zhu and Gregory W. Hammett

    2011-01-10

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence [T.-D. Lee, "On some statistical properties of hydrodynamical and magnetohydrodynamical fields," Q. Appl. Math. 10, 69 (1952)] is taken to study gyrokinetic plasma turbulence: A finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N + 1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  9. Climate Absolute Radiance and Refractivity Observatory (CLARREO)

    NASA Technical Reports Server (NTRS)

    Leckey, John P.

    2015-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is a mission, led and developed by NASA, that will measure a variety of climate variables with an unprecedented accuracy to quantify and attribute climate change. CLARREO consists of three separate instruments: an infrared (IR) spectrometer, a reflected solar (RS) spectrometer, and a radio occultation (RO) instrument. The mission will contain orbiting radiometers with sufficient accuracy, including on orbit verification, to calibrate other space-based instrumentation, increasing their respective accuracy by as much as an order of magnitude. The IR spectrometer is a Fourier Transform spectrometer (FTS) working in the 5 to 50 microns wavelength region with a goal of 0.1 K (k = 3) accuracy. The FTS will achieve this accuracy using phase change cells to verify thermistor accuracy and heated halos to verify blackbody emissivity, both on orbit. The RS spectrometer will measure the reflectance of the atmosphere in the 0.32 to 2.3 microns wavelength region with an accuracy of 0.3% (k = 2). The status of the instrumentation packages and potential mission options will be presented.

  10. Absolute flux measurements for swift atoms

    NASA Technical Reports Server (NTRS)

    Fink, M.; Kohl, D. A.; Keto, J. W.; Antoniewicz, P.

    1987-01-01

    While a torsion balance in vacuum can easily measure the momentum transfer from a gas beam impinging on a surface attached to the balance, this measurement depends on the accommodation coefficients of the atoms with the surface and the distribution of the recoil. A torsion balance is described for making absolute flux measurements independent of recoil effects. The torsion balance is a conventional taut suspension wire design and the Young modulus of the wire determines the relationship between the displacement and the applied torque. A compensating magnetic field is applied to maintain zero displacement and provide critical damping. The unique feature is to couple the impinging gas beam to the torsion balance via a Wood's horn, i.e., a thin wall tube with a gradual 90 deg bend. Just as light is trapped in a Wood's horn by specular reflection from the curved surfaces, the gas beam diffuses through the tube. Instead of trapping the beam, the end of the tube is open so that the atoms exit the tube at 90 deg to their original direction. Therefore, all of the forward momentum of the gas beam is transferred to the torsion balance independent of the angle of reflection from the surfaces inside the tube.

  11. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    SciTech Connect

    Siva, Shankar; Hardcastle, Nicholas; Kron, Tomas; Bressel, Mathias; Callahan, Jason; MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki; Hicks, Rodney J.; Steinfort, Daniel; Ball, David L.; Hofman, Michael S.

    2015-10-01

    Purpose: To investigate {sup 68}Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r{sup 2}=0.99, P<.01), with ventilation strongly negatively linear (r{sup 2}=0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET

  12. Sinusoidal efflux of glutathione in the perfused rat liver. Evidence for a carrier-mediated process.

    PubMed

    Ookhtens, M; Hobdy, K; Corvasce, M C; Aw, T Y; Kaplowitz, N

    1985-01-01

    Turnover of hepatic glutathione in vivo in the rat is almost entirely accounted for by cellular efflux, of which 80-90% is sinusoidal. Thus, sinusoidal efflux play a major quantitative role in homeostasis of hepatic glutathione. Som preliminary observations from our laboratory (1983. J. Pharmacol. Exp. Ther. 224:141-147.) and circumstantial evidence in the literature seemed to imply that the raising of the hepatic glutathione concentration above normal was not accompanied by a rise in the rate of sinusoidal efflux. Based on these observations, we hypothesized that the sinusoidal efflux was probably a saturable process and that at normal levels of hepatic glutathione the efflux behaved as a zero-order process (near-saturation). We tested our hypothesis by the use of isolated rat livers perfused in situ, single pass, with hemoglobin-free, oxygenated buffer medium at pH 7.4 and 37 degrees C. Preliminary experiments established a range of perfusion rates (3-4 ml/min per g) for adequacy of oxygenation, lack of cell injury, and minimization of variability contributed by perfusion rates. Hepatic glutathione was lowered to below normal by a 48-h fast, diethylmaleate (0.1-1.0 ml/kg i.p.), and buthionine sulfoximine (8 mmol/kg i.p.), and raised to above normal by 3-methylcholanthrene (20 mg/kg x 3 d i.p.) and cobalt chloride (0.05-0.27 g/kg-1 subcutaneously). Steady state sinusoidal efflux from each liver was measured over a 1-h perfusion, during which the coefficient of variation of glutathione in perfusates stayed within 10%. Hepatic glutathione efflux as a function of hepatic concentration was characterized by saturable kinetics with sigmoidal (non-hyperbolic) features. The data were fitted best with the Hill model and the following parameter values were estimated: Vmax = 20 nmol/min per g, Km = 3.2 mumol/g, and n = 3 binding/transport sites. The efflux could be inhibited reversibly by sulfobromophthalein-glutathione conjugate but was not affected by the addition of

  13. Sinusoidal efflux of glutathione in the perfused rat liver. Evidence for a carrier-mediated process.

    PubMed Central

    Ookhtens, M; Hobdy, K; Corvasce, M C; Aw, T Y; Kaplowitz, N

    1985-01-01

    Turnover of hepatic glutathione in vivo in the rat is almost entirely accounted for by cellular efflux, of which 80-90% is sinusoidal. Thus, sinusoidal efflux play a major quantitative role in homeostasis of hepatic glutathione. Som preliminary observations from our laboratory (1983. J. Pharmacol. Exp. Ther. 224:141-147.) and circumstantial evidence in the literature seemed to imply that the raising of the hepatic glutathione concentration above normal was not accompanied by a rise in the rate of sinusoidal efflux. Based on these observations, we hypothesized that the sinusoidal efflux was probably a saturable process and that at normal levels of hepatic glutathione the efflux behaved as a zero-order process (near-saturation). We tested our hypothesis by the use of isolated rat livers perfused in situ, single pass, with hemoglobin-free, oxygenated buffer medium at pH 7.4 and 37 degrees C. Preliminary experiments established a range of perfusion rates (3-4 ml/min per g) for adequacy of oxygenation, lack of cell injury, and minimization of variability contributed by perfusion rates. Hepatic glutathione was lowered to below normal by a 48-h fast, diethylmaleate (0.1-1.0 ml/kg i.p.), and buthionine sulfoximine (8 mmol/kg i.p.), and raised to above normal by 3-methylcholanthrene (20 mg/kg x 3 d i.p.) and cobalt chloride (0.05-0.27 g/kg-1 subcutaneously). Steady state sinusoidal efflux from each liver was measured over a 1-h perfusion, during which the coefficient of variation of glutathione in perfusates stayed within 10%. Hepatic glutathione efflux as a function of hepatic concentration was characterized by saturable kinetics with sigmoidal (non-hyperbolic) features. The data were fitted best with the Hill model and the following parameter values were estimated: Vmax = 20 nmol/min per g, Km = 3.2 mumol/g, and n = 3 binding/transport sites. The efflux could be inhibited reversibly by sulfobromophthalein-glutathione conjugate but was not affected by the addition of

  14. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOEpatents

    Prasad, Mano K.; Snyderman, Neal J.; Rowland, Mark S.

    2015-12-01

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  15. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOEpatents

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  16. Positioning, alignment and absolute pointing of the ANTARES neutrino telescope

    NASA Astrophysics Data System (ADS)

    Fehr, F.; Distefano, C.; Antares Collaboration

    2010-01-01

    A precise detector alignment and absolute pointing is crucial for point-source searches. The ANTARES neutrino telescope utilises an array of hydrophones, tiltmeters and compasses for the relative positioning of the optical sensors. The absolute calibration is accomplished by long-baseline low-frequency triangulation of the acoustic reference devices in the deep-sea with a differential GPS system at the sea surface. The absolute pointing can be independently verified by detecting the shadow of the Moon in cosmic rays.

  17. The ability of intra-operative perfusion mapping with laser-assisted indocyanine green angiography to predict mastectomy flap necrosis in breast reconstruction: a prospective trial.

    PubMed

    Munabi, Naikhoba C O; Olorunnipa, Olushola B; Goltsman, David; Rohde, Christine H; Ascherman, Jeffrey A

    2014-04-01

    Mastectomy skin flap ischaemia leading to necrosis is a common occurrence. Laser-assisted indocyanine green (ICG) angiography can assist to locate these poorly perfused areas intra-operatively. Our study aims to identify specific perfusion values produced by ICG angiography that accurately predict mastectomy flap necrosis. A total of 42 patients undergoing autologous or implant-based breast reconstruction had mastectomy flaps imaged using laser-assisted ICG angiography at the completion of reconstruction. Intra-operative perfusion values were correlated with postoperative skin flap outcomes. Risk factors for abnormal perfusion were recorded and analysed. A total of 62 breast reconstructions were imaged, including 48 tissue expander reconstructions, six transverse rectus abdominis myocutaneous (TRAM) flaps, six deep inferior epigastric perforator (DIEP) flaps and two direct-to-implant reconstructions. Eight cases (13%) of full-thickness skin necrosis were identified postoperatively. A SPY Elite(®) value of ≤ 7 accurately predicted the development of flap necrosis at 88% sensitivity and 83% specificity. False-positive cases (those with perfusion values ≤ 7 which did not develop necrosis) were more likely to have a smoking history and/or to have had an epinephrine-containing tumescent solution used during mastectomy. Excluding patients with smoking or epinephrine use, a SPY value of ≤ 7 predicted flap necrosis with a sensitivity of 83% and specificity of 97%. Thus, these data suggest that laser-assisted ICG angiography predicts postoperative outcomes with high accuracy. In our series, a SPY value of ≤ 7 correlated well with mastectomy flap necrosis. Furthermore, smoking and intra-operative injections containing epinephrine should be considered when evaluating low perfusion values as they can lead to false-positive test results.

  18. Absolute and Convective Instability of a Liquid Jet

    NASA Technical Reports Server (NTRS)

    Lin, S. P.; Hudman, M.; Chen, J. N.

    1999-01-01

    The existence of absolute instability in a liquid jet has been predicted for some time. The disturbance grows in time and propagates both upstream and downstream in an absolutely unstable liquid jet. The image of absolute instability is captured in the NASA 2.2 sec drop tower and reported here. The transition from convective to absolute instability is observed experimentally. The experimental results are compared with the theoretical predictions on the transition Weber number as functions of the Reynolds number. The role of interfacial shear relative to all other relevant forces which cause the onset of jet breakup is explained.

  19. Quantitative, dynamic and noninvasive determination of skeletal muscle perfusion in mouse leg by NMR arterial spin-labeled imaging.

    PubMed

    Bertoldi, Didier; Loureiro de Sousa, Paulo; Fromes, Yves; Wary, Claire; Carlier, Pierre G

    2008-11-01

    Because mouse may relatively easily be genetically tailored to develop equivalent of human muscular diseases or to present controlled alterations of mechanisms involved in vasoregulation, it has become the prevalent species to explore such questions. However, the very small size of the animals represents a serious limitation when evaluating the functional consequences of these genetic manipulations. In this context, the recourse to arterial spin labeling (ASL) nuclear magnetic resonance (NMR) methods in which arterial water spins act as an endogenous and freely diffusible tracer of perfusion is tempting but challenging. This article shows that despite the small size of the animal, mouse muscle perfusion may be measured, at rest and in conditions of reactive hyperemia, using saturation inversion recovery sequence, a pulsed ASL variant, combined with NMR imaging. Baseline perfusion values in the mouse leg were 17+/-11 ml.min(-1).100 g(-1) (n=11) and were comparable to microsphere data from the literature. Under ischemia, leg perfusion was 1.2+/-9.3 ml.min(-1).100 g(-1) (n=11). The difference observed between basal and ischemic measurements was statistically different (P=.0001). The temporal pattern of hyperemia in mouse muscle was coherent with previously published measurements in humans and in rats. The mean peak perfusion was 62+/-24 ml.min(-1).100 g(-1) (n=6) occurring 48+/-27 s after the end of occlusion. In conclusion, this study demonstrated the ability of ASL combined to NMR imaging to quantify skeletal muscle perfusion in mice legs, both at rest and dynamically.

  20. Prostaglandin E1 Increases Microcirculation in Random Pattern Flaps on Rats Measured with Laser Doppler Perfusion Imaging

    PubMed Central

    Sneistrup, Christian; Berg, Thomas Moe

    2017-01-01

    Background: Reconstructive procedures with pedicled and free flaps are associated with a risk of ischemia. Prostaglandin E1 (PGE1) is a hormone-like substance with known antiischemic and tissue-protective effects. The aim of this study was to evaluate the effect of PGE1 on the microcirculation in random pattern skin flaps on rats. Methods: Twenty-four rats were divided into 2 groups: an intervention group given PGE1 for 6 hours and a control group given saline. The flap (2 × 10 cm) was created on the back of the rats, and the microcirculation was monitored with laser Doppler perfusion imaging in 5 different zones (1, proximal; 5, distal) before surgery and after 60, 180, and 360 minutes postoperatively. Results: Before surgery, there was no difference in the perfusion in any zones between the intervention group and the control group. The mean perfusion values in zone 1 in the intervention group were significantly higher than those in the control group at 60, 180, and 360 minutes postoperatively (P = 0.02, P = 0.05, and P = 0.04, respectively). At 360 minutes, we also found significantly higher levels of perfusion in the intervention group in zones 4 and 5 (P = 0.05 and P = 0.03, respectively) compared with the controls. Comparing the perfusion at 360 to 60 minutes in the intervention group, we found a significant increase in microcirculation in all zones, which were not seen in the control group. Conclusion: PGE1 increased perfusion in the dermal random pattern flaps on rats. PMID:28203503

  1. Strong thermal leptogenesis and the absolute neutrino mass scale

    SciTech Connect

    Bari, Pasquale Di; King, Sophie E.; Fiorentin, Michele Re E-mail: sk1806@soton.ac.uk

    2014-03-01

    We show that successful strong thermal leptogenesis, where the final asymmetry is independent of the initial conditions and in particular a large pre-existing asymmetry is efficiently washed-out, favours values of the lightest neutrino mass m{sub 1}∼>10 meV for normal ordering (NO) and m{sub 1}∼>3 meV for inverted ordering (IO) for models with orthogonal matrix entries respecting |Ω{sub ij}{sup 2}|∼<2. We show analytically why lower values of m{sub 1} require a higher level of fine tuning in the seesaw formula and/or in the flavoured decay parameters (in the electronic for NO, in the muonic for IO). We also show how this constraint exists thanks to the measured values of the neutrino mixing angles and could be tightened by a future determination of the Dirac phase. Our analysis also allows us to place a more stringent constraint for a specific model or class of models, such as SO(10)-inspired models, and shows that some models cannot realise strong thermal leptogenesis for any value of m{sub 1}. A scatter plot analysis fully supports the analytical results. We also briefly discuss the interplay with absolute neutrino mass scale experiments concluding that they will be able in the coming years to either corner strong thermal leptogenesis or find positive signals pointing to a non-vanishing m{sub 1}. Since the constraint is much stronger for NO than for IO, it is very important that new data from planned neutrino oscillation experiments will be able to solve the ambiguity.

  2. Luxury perfusion phenomenon in acute herpes simplex virus encephalitis.

    PubMed

    Tanaka, M; Uesugi, M; Igeta, Y; Kondo, S; Sun, X; Hirai, S

    1995-02-01

    In a patient with acute herpes simplex virus (HSV) encephalitis, positron emission tomography (PET) demonstrated increased cerebral blood flow in the affected temporal lobe accompanied by reduction in the cerebral oxygen extraction fraction and the cerebral metabolic rate of oxygen, i.e., luxury perfusion. Follow-up PET studies showed reduction in cerebral perfusion until it was more closely coupled with oxygen metabolism after the resolution of the acute inflammation. These findings support previous single photon emission computed tomographic data and provide a pathophysiological background for the occurrence of hyperperfusion in HSV encephalitis. This is an interesting example of the luxury perfusion phenomenon occurring in a disease other than cerebral ischemia.

  3. Contactless mapping of rhythmical phenomena in tissue perfusion using PPGI

    NASA Astrophysics Data System (ADS)

    Huelsbusch, Markus; Blazek, Vladimir

    2002-04-01

    This paper presents the experimental setup and preliminary results of a near infrared CCD camera based Photoplethysmography Imaging (PPGI) system, which has been shown to be suitable for contactless and spatially resolved assessment of rhythmical blood volume changes in the skin. To visualize the complex rhythmical patterns in the dermal perfusion the Wavelet Transform is utilized. It is able to jointly assess time and frequency behavior of signals and thus allows to analyze instationary oscillations and variabilities in the different human rhythmics. The presented system is expected to provide new insights into the functional sequences of physiological tissue perfusion as well as of the perfusion status in ulcer formation and wound healing.

  4. Absolute Plate Velocities from Seismic Anisotropy

    NASA Astrophysics Data System (ADS)

    Kreemer, Corné; Zheng, Lin; Gordon, Richard

    2015-04-01

    The orientation of seismic anisotropy inferred beneath plate interiors may provide a means to estimate the motions of the plate relative to the sub-asthenospheric mantle. Here we analyze two global sets of shear-wave splitting data, that of Kreemer [2009] and an updated and expanded data set, to estimate plate motions and to better understand the dispersion of the data, correlations in the errors, and their relation to plate speed. We also explore the effect of using geologically current plate velocities (i.e., the MORVEL set of angular velocities [DeMets et al. 2010]) compared with geodetically current plate velocities (i.e., the GSRM v1.2 angular velocities [Kreemer et al. 2014]). We demonstrate that the errors in plate motion azimuths inferred from shear-wave splitting beneath any one tectonic plate are correlated with the errors of other azimuths from the same plate. To account for these correlations, we adopt a two-tier analysis: First, find the pole of rotation and confidence limits for each plate individually. Second, solve for the best fit to these poles while constraining relative plate angular velocities to consistency with the MORVEL relative plate angular velocities. The SKS-MORVEL absolute plate angular velocities (based on the Kreemer [2009] data set) are determined from the poles from eight plates weighted proportionally to the root-mean-square velocity of each plate. SKS-MORVEL indicates that eight plates (Amur, Antarctica, Caribbean, Eurasia, Lwandle, Somalia, Sundaland, and Yangtze) have angular velocities that differ insignificantly from zero. The net rotation of the lithosphere is 0.25±0.11° Ma-1 (95% confidence limits) right-handed about 57.1°S, 68.6°E. The within-plate dispersion of seismic anisotropy for oceanic lithosphere (σ=19.2° ) differs insignificantly from that for continental lithosphere (σ=21.6° ). The between-plate dispersion, however, is significantly smaller for oceanic lithosphere (σ=7.4° ) than for continental

  5. What Value "Value Added"?

    ERIC Educational Resources Information Center

    Richards, Andrew

    2015-01-01

    Two quantitative measures of school performance are currently used, the average points score (APS) at Key Stage 2 and value-added (VA), which measures the rate of academic improvement between Key Stage 1 and 2. These figures are used by parents and the Office for Standards in Education to make judgements and comparisons. However, simple…

  6. Orion Absolute Navigation System Progress and Challenge

    NASA Technical Reports Server (NTRS)

    Holt, Greg N.; D'Souza, Christopher

    2012-01-01

    The absolute navigation design of NASA's Orion vehicle is described. It has undergone several iterations and modifications since its inception, and continues as a work-in-progress. This paper seeks to benchmark the current state of the design and some of the rationale and analysis behind it. There are specific challenges to address when preparing a timely and effective design for the Exploration Flight Test (EFT-1), while still looking ahead and providing software extensibility for future exploration missions. The primary onboard measurements in a Near-Earth or Mid-Earth environment consist of GPS pseudo-range and delta-range, but for future explorations missions the use of star-tracker and optical navigation sources need to be considered. Discussions are presented for state size and composition, processing techniques, and consider states. A presentation is given for the processing technique using the computationally stable and robust UDU formulation with an Agee-Turner Rank-One update. This allows for computational savings when dealing with many parameters which are modeled as slowly varying Gauss-Markov processes. Preliminary analysis shows up to a 50% reduction in computation versus a more traditional formulation. Several state elements are discussed and evaluated, including position, velocity, attitude, clock bias/drift, and GPS measurement biases in addition to bias, scale factor, misalignment, and non-orthogonalities of the accelerometers and gyroscopes. Another consideration is the initialization of the EKF in various scenarios. Scenarios such as single-event upset, ground command, and cold start are discussed as are strategies for whole and partial state updates as well as covariance considerations. Strategies are given for dealing with latent measurements and high-rate propagation using multi-rate architecture. The details of the rate groups and the data ow between the elements is discussed and evaluated.

  7. Evaluation of the Absolute Regional Temperature Potential

    NASA Technical Reports Server (NTRS)

    Shindell, D. T.

    2012-01-01

    The Absolute Regional Temperature Potential (ARTP) is one of the few climate metrics that provides estimates of impacts at a sub-global scale. The ARTP presented here gives the time-dependent temperature response in four latitude bands (90-28degS, 28degS-28degN, 28-60degN and 60-90degN) as a function of emissions based on the forcing in those bands caused by the emissions. It is based on a large set of simulations performed with a single atmosphere-ocean climate model to derive regional forcing/response relationships. Here I evaluate the robustness of those relationships using the forcing/response portion of the ARTP to estimate regional temperature responses to the historic aerosol forcing in three independent climate models. These ARTP results are in good accord with the actual responses in those models. Nearly all ARTP estimates fall within +/-20%of the actual responses, though there are some exceptions for 90-28degS and the Arctic, and in the latter the ARTP may vary with forcing agent. However, for the tropics and the Northern Hemisphere mid-latitudes in particular, the +/-20% range appears to be roughly consistent with the 95% confidence interval. Land areas within these two bands respond 39-45% and 9-39% more than the latitude band as a whole. The ARTP, presented here in a slightly revised form, thus appears to provide a relatively robust estimate for the responses of large-scale latitude bands and land areas within those bands to inhomogeneous radiative forcing and thus potentially to emissions as well. Hence this metric could allow rapid evaluation of the effects of emissions policies at a finer scale than global metrics without requiring use of a full climate model.

  8. Absolute determination of local tropospheric OH concentrations

    NASA Technical Reports Server (NTRS)

    Armerding, Wolfgang; Comes, Franz-Josef

    1994-01-01

    Long path absorption (LPA) according to Lambert Beer's law is a method to determine absolute concentrations of trace gases such as tropospheric OH. We have developed a LPA instrument which is based on a rapid tuning of the light source which is a frequency doubled dye laser. The laser is tuned across two or three OH absorption features around 308 nm with a scanning speed of 0.07 cm(exp -1)/microsecond and a repetition rate of 1.3 kHz. This high scanning speed greatly reduces the fluctuation of the light intensity caused by the atmosphere. To obtain the required high sensitivity the laser output power is additionally made constant and stabilized by an electro-optical modulator. The present sensitivity is of the order of a few times 10(exp 5) OH per cm(exp 3) for an acquisition time of a minute and an absorption path length of only 1200 meters so that a folding of the optical path in a multireflection cell was possible leading to a lateral dimension of the cell of a few meters. This allows local measurements to be made. Tropospheric measurements have been carried out in 1991 resulting in the determination of OH diurnal variation at specific days in late summer. Comparison with model calculations have been made. Interferences are mainly due to SO2 absorption. The problem of OH self generation in the multireflection cell is of minor extent. This could be shown by using different experimental methods. The minimum-maximum signal to noise ratio is about 8 x 10(exp -4) for a single scan. Due to the small size of the absorption cell the realization of an open air laboratory is possible in which by use of an additional UV light source or by additional fluxes of trace gases the chemistry can be changed under controlled conditions allowing kinetic studies of tropospheric photochemistry to be made in open air.

  9. Absolute Radiometric Calibration of KOMPSAT-3A

    NASA Astrophysics Data System (ADS)

    Ahn, H. Y.; Shin, D. Y.; Kim, J. S.; Seo, D. C.; Choi, C. U.

    2016-06-01

    This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A) performed by the Korea Aerospace Research Institute (KARI) and the Pukyong National University Remote Sensing Group (PKNU RSG) in 2015.The primary stages of this study are summarized as follows: (1) A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2) To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4). Correlations between top-of-atmosphere (TOA) radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB) region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  10. An in vivo autotransplant model of renal preservation: cold storage versus machine perfusion in the prevention of ischemia/reperfusion injury.

    PubMed

    La Manna, Gaetano; Conte, Diletta; Cappuccilli, Maria Laura; Nardo, Bruno; D'Addio, Francesca; Puviani, Lorenza; Comai, Giorgia; Bianchi, Francesca; Bertelli, Riccardo; Lanci, Nicole; Donati, Gabriele; Scolari, Maria Piera; Faenza, Alessandro; Stefoni, Sergio

    2009-07-01

    There is increasing proof that organ preservation by machine perfusion is able to limit ischemia/reperfusion injury in kidney transplantation. This study was designed to compare the efficiency in hypothermic organ preservation by machine perfusion or cold storage in an animal model of kidney autotransplantation. Twelve pigs underwent left nephrectomy after warm ischemic time; the organs were preserved in machine perfusion (n = 6) or cold storage (n = 6) and then autotransplanted with immediate contralateral nephrectomy. The following parameters were compared between the two groups of animals: hematological and urine indexes of renal function, blood/gas analysis values, histological features, tissue adenosine-5'-triphosphate (ATP) content, perforin gene expression in kidney biopsies, and organ weight changes were compared before and after preservation. The amount of cellular ATP was significantly higher in organs preserved by machine perfusion; moreover, the study of apoptosis induction revealed an enhanced perforin expression in the kidneys, which underwent simple hypothermic preservation compared to the machine-preserved ones. Organ weight was significantly decreased after cold storage, but it remained quite stable for machine-perfused kidneys. The present model seems to suggest that organ preservation by hypothermic machine perfusion is able to better control cellular impairment in comparison with cold storage.

  11. Dynamic Contrast-Enhanced MRI Perfusion Parameters as Imaging Biomarkers of Angiogenesis

    PubMed Central

    2016-01-01

    Hypoxia in the tumor microenvironment is the leading factor in angiogenesis. Angiogenesis can be identified by dynamic contrast-enhanced breast MRI (DCE MRI). Here we investigate the relationship between perfusion parameters on DCE MRI and angiogenic and prognostic factors in patients with invasive ductal carcinoma (IDC). Perfusion parameters (Ktrans, kep and ve) of 81 IDC were obtained using histogram analysis. Twenty-fifth, 50th and 75th percentile values were calculated and were analyzed for association with microvessel density (MVD), vascular endothelial growth factor (VEGF) and conventional prognostic factors. Correlation between MVD and ve50 was positive (r = 0.33). Ktrans50 was higher in tumors larger than 2 cm than in tumors smaller than 2 cm. In multivariate analysis, Ktrans50 was affected by tumor size and MVD with 12.8% explanation. There was significant association between Ktrans50 and tumor size and MVD. Therefore we conclude that DCE MRI perfusion parameters are potential imaging biomarkers for prediction of tumor angiogenesis and aggressiveness. PMID:28036342

  12. Cryotherapy-Induced Persistent Vasoconstriction After Cutaneous Cooling: Hysteresis Between Skin Temperature and Blood Perfusion.

    PubMed

    Khoshnevis, Sepideh; Craik, Natalie K; Matthew Brothers, R; Diller, Kenneth R

    2016-03-01

    The goal of this study was to investigate the persistence of cold-induced vasoconstriction following cessation of active skin-surface cooling. This study demonstrates a hysteresis effect that develops between skin temperature and blood perfusion during the cooling and subsequent rewarming period. An Arctic Ice cryotherapy unit (CTU) was applied to the knee region of six healthy subjects for 60 min of active cooling followed by 120 min of passive rewarming. Multiple laser Doppler flowmetry perfusion probes were used to measure skin blood flow (expressed as cutaneous vascular conductance (CVC)). Skin surface cooling produced a significant reduction in CVC (P < 0.001) that persisted throughout the duration of the rewarming period. In addition, there was a hysteresis effect between CVC and skin temperature during the cooling and subsequent rewarming cycle (P < 0.01). Mixed model regression (MMR) showed a significant difference in the slopes of the CVC-skin temperature curves during cooling and rewarming (P < 0.001). Piecewise regression was used to investigate the temperature thresholds for acceleration of CVC during the cooling and rewarming periods. The two thresholds were shown to be significantly different (P = 0.003). The results show that localized cooling causes significant vasoconstriction that continues beyond the active cooling period despite skin temperatures returning toward baseline values. The significant and persistent reduction in skin perfusion may contribute to nonfreezing cold injury (NFCI) associated with cryotherapy.

  13. Cryotherapy-Induced Persistent Vasoconstriction After Cutaneous Cooling: Hysteresis Between Skin Temperature and Blood Perfusion

    PubMed Central

    Khoshnevis, Sepideh; Craik, Natalie K.; Matthew Brothers, R.; Diller, Kenneth R.

    2016-01-01

    The goal of this study was to investigate the persistence of cold-induced vasoconstriction following cessation of active skin-surface cooling. This study demonstrates a hysteresis effect that develops between skin temperature and blood perfusion during the cooling and subsequent rewarming period. An Arctic Ice cryotherapy unit (CTU) was applied to the knee region of six healthy subjects for 60 min of active cooling followed by 120 min of passive rewarming. Multiple laser Doppler flowmetry perfusion probes were used to measure skin blood flow (expressed as cutaneous vascular conductance (CVC)). Skin surface cooling produced a significant reduction in CVC (P < 0.001) that persisted throughout the duration of the rewarming period. In addition, there was a hysteresis effect between CVC and skin temperature during the cooling and subsequent rewarming cycle (P < 0.01). Mixed model regression (MMR) showed a significant difference in the slopes of the CVC–skin temperature curves during cooling and rewarming (P < 0.001). Piecewise regression was used to investigate the temperature thresholds for acceleration of CVC during the cooling and rewarming periods. The two thresholds were shown to be significantly different (P = 0.003). The results show that localized cooling causes significant vasoconstriction that continues beyond the active cooling period despite skin temperatures returning toward baseline values. The significant and persistent reduction in skin perfusion may contribute to nonfreezing cold injury (NFCI) associated with cryotherapy. PMID:26632263

  14. Lung transplantation from donors after circulatory death using portable ex vivo lung perfusion

    PubMed Central

    Bozso, Sabin; Vasanthan, Vishnu; Luc, Jessica GY; Kinaschuk, Katie; Freed, Darren; Nagendran, Jayan

    2015-01-01

    BACKGROUND: Donation after circulatory death is a novel method of increasing the number of donor lungs available for transplantation. Using organs from donors after circulatory death has the potential to increase the number of transplants performed. METHODS: Three bilateral lung transplants from donors after circulatory death were performed over a six-month period. Following organ retrieval, all sets of lungs were placed on a portable ex vivo lung perfusion device for evaluation and preservation. RESULTS: Lung function remained stable during portable ex vivo perfusion, with improvement in partial pressure of oxygen/fraction of inspired oxygen ratios. Mechanical ventilation was discontinued within 48 h for each recipient and no patient stayed in the intensive care unit longer than eight days. There was no postgraft dysfunction at 72 h in two of the three recipients. Ninety-day mortality for all recipients was 0% and all maintain excellent forced expiratory volume in 1 s and forced vital capacity values post-transplantation. CONCLUSION: The authors report excellent results with their initial experience using donors after circulatory death after portable ex vivo lung perfusion. It is hoped this will allow for the most efficient use of available donor lungs, leading to more transplants and fewer deaths for potential recipients on wait lists. PMID:25379654

  15. Feasibility of Flat Panel Detector CT in Perfusion Assessment of Brain Arteriovenous Malformations: Initial Clinical Experience.

    PubMed

    Garcia, M; Okell, T W; Gloor, M; Chappell, M A; Jezzard, P; Bieri, O; Byrne, J V

    2017-02-16

    The different results from flat panel detector CT in various pathologies have provoked some discussion. Our aim was to assess the role of flat panel detector CT in brain arteriovenous malformations, which has not yet been assessed. Five patients with brain arteriovenous malformations were studied with flat panel detector CT, DSC-MR imaging, and vessel-encoded pseudocontinuous arterial spin-labeling. In glomerular brain arteriovenous malformations, perfusion was highest next to the brain arteriovenous malformation with decreasing values with increasing distance from the lesion. An inverse tendency was observed in the proliferative brain arteriovenous malformation. Flat panel detector CT, originally thought to measure blood volume, correlated more closely with arterial spin-labeling-CBF and DSC-CBF than with DSC-CBV. We conclude that flat panel detector CT perfusion depends on the time point chosen for data collection, which is triggered too early in these patients (ie, when contrast agent appears in the superior sagittal sinus after rapid shunting through the brain arteriovenous malformation). This finding, in combination with high data variability, makes flat panel detector CT inappropriate for perfusion assessment in brain arteriovenous malformations.

  16. Perfusion, oxygenation status and growth of experimental tumors upon photodynamic therapy with Pd-bacteriopheophorbide.

    PubMed

    Kelleher, Debra K; Thews, Oliver; Scherz, Avigdor; Salomon, Yoram; Vaupel, Peter

    2004-06-01

    The aim of this study was to assess the anti-tumor effect of photodynamic therapy (PDT) using a novel bacteriochlorophyll derivative, palladium-bacteriopheophorbide (TOOKAD) on tumor growth, perfusion and oxygenation. Rat DS-sarcomas were treated with either TOOKAD-PDT (2 mg/kg, i.v., immediate illumination) or one of the control treatments (sham-treatment, illumination without photosensitizer, or photosensitizer without illumination). The light source was an infrared-A irradiator fitted with appropriate filters, so that the wavelengths applied (665-800 nm) included the absorption maximum of TOOKAD at 763 nm. Tumor volume was monitored for 90 days after treatment or until a target volume (3.5 ml) was reached. TOOKAD-PDT dramatically inhibited tumor growth with 92% of tumors not reaching the target volume within the observation period. In further experiments, tumor perfusion was assessed using laser Doppler flowmetry. Upon TOOKAD-PDT treatment, a rapid, pronounced decrease in perfusion was seen, down to levels corresponding to only 3% of initial values. Tumor oxygenation monitoring revealed parallel decreases, with levels corresponding to anoxia being reached. The significant anti-tumor effects presented in this report, taken together with the chemical and pharmacokinetic properties of the novel photosensitizer TOOKAD, underline the therapeutic potential of this approach in which flow stasis and induction of anoxia are key elements.

  17. Reduction in cerebral perfusion after heroin administration: a resting state arterial spin labeling study.

    PubMed

    Denier, Niklaus; Gerber, Hana; Vogel, Marc; Klarhöfer, Markus; Riecher-Rossler, Anita; Wiesbeck, Gerhard A; Lang, Undine E; Borgwardt, Stefan; Walter, Marc

    2013-01-01

    Heroin dependence is a chronic relapsing brain disorder, characterized by the compulsion to seek and use heroin. Heroin itself has a strong potential to produce subjective experiences characterized by intense euphoria, relaxation and release from craving. The neurofunctional foundations of these perceived effects are not well known. In this study, we have used pharmacological magnetic resonance imaging (phMRI) in 15 heroin-dependent patients from a stable heroin-assisted treatment program to observe the steady state effects of heroin (60 min after administration). Patients were scanned in a cross-over and placebo controlled design. They received an injection of their regular dose of heroin or saline (placebo) before or after the scan. As phMRI method, we used a pulsed arterial spin labeling (ASL) sequence based on a flow-sensitive alternating inversion recovery (FAIR) spin labeling scheme combined with a single-shot 3D GRASE (gradient-spin echo) readout on a 3 Tesla scanner. Analysis was performed with Statistical Parametric Mapping (SPM 8), using a general linear model for whole brain comparison between the heroin and placebo conditions. We found that compared to placebo, heroin was associated with reduced perfusion in the left anterior cingulate cortex (ACC), the left medial prefrontal cortex (mPFC) and in the insula (both hemispheres). Analysis of extracted perfusion values indicate strong effect sizes and no gender related differences. Reduced perfusion in these brain areas may indicate self- and emotional regulation effects of heroin in maintenance treatment.

  18. Uptake and degradation of cytoplasmic RNA by lysosomes in the perfused rat liver

    SciTech Connect

    Heydrick, S.J.; Lardeux, B.; Mortimore, G.E.

    1987-05-01

    The release of (/sup 14/C)cytidine has been shown previously to be a valid marker for RNA degradation in rat hepatocytes. The breakdown of RNA measured with this marker in perfused livers prelabeled in vivo with (6-/sup 14/C)orotic acid was found to be regulated acutely by perfusate amino acids over a wide range, from 0.29 to 3.48%/h. This regulation paralleled that of lysosomal proteolysis. Chloroquine inhibited RNA degradation 60-70%. In subsequent cell fractionation studies labelled cytidine was released; the distribution of this release paralleled that of a lysosomal marker enzyme. The release plateaued after two hours, defining a distinct lysosomal pool of RNA. The lysosomal location of the RNA pool was confirmed in experiments where a 22% increase in the apparent pool size was obtained by lowering the homogenate pH from 7.0 to 5.5. The pool size correlated linearly with the rate of RNA degradation measured during perfusion, giving a turnover constant in reasonable agreement with values reported for autophagy. These results indicate that cytoplasmic RNA degradation occurs primarily in the lysosome and is regulated under these conditions by the amino acid control of lysosomal sequestration of cytoplasm.

  19. Risk assessment by myocardial perfusion imaging for coronary revascularization, medical therapy, and noncardiac surgery.

    PubMed

    Papaioannou, Georgios I; Heller, Gary V

    2003-01-01

    Stress myocardial perfusion imaging (MPI) has become an important tool in risk stratification of patients with known coronary artery disease. A normal myocardial perfusion scan has a high negative predictive value and is associated with low annual mortality rate (< 1%). Patients with extensive ischemia (> 20% of the left ventricle), defects in more than 1 coronary vascular territory, transient or persistent left ventricular cavity dilation, and ejection fraction less than 45% have a high annual mortality rate (> 3%). Those patients should undergo coronary revascularization whenever feasible, as the cardiac event rate increases in proportion to the magnitude of the jeopardized myocardium. Stress MPI can be used to demonstrate ischemia in patients with symptoms early after coronary artery bypass surgery (< 5 years) or in those without symptoms late (>/= 5 years) after coronary artery bypass surgery. With respect to patients who underwent percutaneous interventions, stress MPI can help detect in-stent restenosis early after the intervention (3-6 months) or assess the progression of native coronary disease afterward. Since preliminary data suggest that a reduction in the perfusion defect size may translate to a reduction of coronary events, stress MPI can help assess the efficacy of medical management of coronary disease. Finally, stress MPI is indicated for perioperative cardiac risk stratification for noncardiac surgery in patients with intermediate risk predictors (mild angina, prior myocardial infarction or heart failure symptoms, diabetes mellitus, renal insufficiency) and poor functional capacity or in those who undergo high-risk surgery with significant implications in further preoperative management.

  20. Calculation of the Respiratory Modulation of the Photoplethysmogram (DPOP) Incorporating a Correction for Low Perfusion

    PubMed Central

    Addison, Paul S.; Wang, Rui; McGonigle, Scott J.; Bergese, Sergio D.

    2014-01-01

    DPOP quantifies respiratory modulations in the photoplethysmogram. It has been proposed as a noninvasive surrogate for pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. The correlation between DPOP and PPV may degrade due to low perfusion effects. We implemented an automated DPOP algorithm with an optional correction for low perfusion. These two algorithm variants (DPOPa and DPOPb) were tested on data from 20 mechanically ventilated OR patients split into a benign “stable region” subset and a whole record “global set.” Strong correlation was found between DPOP and PPV for both algorithms when applied to the stable data set: R = 0.83/0.85 for DPOPa/DPOPb. However, a marked improvement was found when applying the low perfusion correction to the global data set: R = 0.47/0.73 for DPOPa/DPOPb. Sensitivities, Specificities, and AUCs were 0.86, 0.70, and 0.88 for DPOPa/stable region; 0.89, 0.82, and 0.92 for DPOPb/stable region; 0.81, 0.61, and 0.73 for DPOPa/global region; 0.83, 0.76, and 0.86 for DPOPb/global region. An improvement was found in all results across both data sets when using the DPOPb algorithm. Further, DPOPb showed marked improvements, both in terms of its values, and correlation with PPV, for signals exhibiting low percent modulations. PMID:25177348

  1. In-vivo quantitative evaluation of perfusion zones and perfusion gradient in the deep inferior epigastric artery perforator flap

    NASA Astrophysics Data System (ADS)

    Saint-Cyr, Michel; Lakhiani, Chrisovalantis; Cheng, Angela; Mangum, Michael; Liang, Jinyang; Teotia, Sumeet; Livingston, Edward H.; Zuzak, Karel J.

    2013-03-01

    The selection of well-vascularized tissue during DIEP flap harvest remains controversial. While several studies have elucidated cross-midline perfusion, further characterization of perfusion to the ipsilateral hemiabdomen is necessary for minimizing rates of fat necrosis or partial fat necrosis in bilateral DIEP flaps. Eighteen patients (29 flaps) underwent DIEP flap harvest using a prospectively designed protocol. Perforators were marked and imaged with a novel system for quantitatively measuring tissue oxygenation, the Digital Light Hyperspectral Imager. Images were then analyzed to determine if perforator selection influenced ipsilateral flap perfusion. Flaps based on a single lateral row perforator (SLRP) were found to have a higher level of hemoglobin oxygenation in Zone I (mean %HbO2 = 76.1) compared to single medial row perforator (SMRP) flaps (%HbO2 = 71.6). Perfusion of Zone III relative to Zone I was similar between SLRP and SMRP flaps (97.4% vs. 97.9%, respectively). These differences were not statistically significant (p>0.05). Perfusion to the lateral edge of the flap was slightly greater for SLRP flaps compared SMRP flaps (92.1% vs. 89.5%, respectively). SMRP flaps had superior perfusion travelling inferiorly compared to SLRP flaps (88.8% vs. 83.9%, respectively). Overall, it was observed that flaps were better perfused in the lateral direction than inferiorly. Significant differences in perfusion gradients directed inferiorly or laterally were observed, and perforator selection influenced perfusion in the most distal or inferior aspects of the flap. This suggests broader clinical implications for flap design that merit further investigation.

  2. Determination of absolute threshold and just noticeable difference in the sensory perception of pungency.

    PubMed

    Orellana-Escobedo, L; Ornelas-Paz, J J; Olivas, G I; Guerrero-Beltran, J A; Jimenez-Castro, J; Sepulveda, D R

    2012-03-01

    Absolute threshold and just noticeable difference (JND) were determined for the perception of pungency using chili pepper in aqueous solutions. Absolute threshold and JND were determined using 2 alternative forced-choice sensory tests tests. High-performance liquid chromatography technique was used to determine capsaicinoids concentration in samples used for sensory analysis. Sensory absolute threshold was 0.050 mg capsaicinoids/kg sample. Five JND values were determined using 5 reference solutions with different capsaicinoids concentration. JND values changed proportionally as capsaicinoids concentration of the reference sample solutions changed. Weber fraction remained stable for the first 4 reference capsaicinoid solutions (0.05, 0.11, 0.13, and 0.17 mg/kg) but changed when the most concentrated reference capsaicinoids solution was used (0.23 mg/kg). Quantification limit for instrumental analysis was 1.512 mg/kg capsaicinoids. Sensory methods employed in this study proved to be more sensitive than instrumental methods. Practical Application: A better understanding of the process involved in the sensory perception of pungency is currently required because "hot" foods are becoming more popular in western cuisine. Absolute thresholds and differential thresholds are useful tools in the formulation and development of new food products. These parameters may help in defining how much chili pepper is required in a formulated product to ensure a perceptible level of pungency, as well as in deciding how much more chili pepper is required in a product to produce a perceptible increase in its pungency.

  3. Resting cerebral blood flow alterations in chronic traumatic brain injury: an arterial spin labeling perfusion FMRI study.

    PubMed

    Kim, Junghoon; Whyte, John; Patel, Sunil; Avants, Brian; Europa, Eduardo; Wang, Jiongjiong; Slattery, John; Gee, James C; Coslett, H Branch; Detre, John A

    2010-08-01

    Non-invasive measurement of resting state cerebral blood flow (CBF) may reflect alterations of brain structure and function after traumatic brain injury (TBI). However, previous imaging studies of resting state brain in chronic TBI have been limited by several factors, including measurement in relative rather than absolute units, use of crude spatial registration methods, exclusion of subjects with substantial focal lesions, and exposure to ionizing radiation, which limits repeated assessments. This study aimed to overcome those obstacles by measuring absolute CBF with an arterial spin labeling perfusion fMRI technique, and using an image preprocessing protocol that is optimized for brains with mixed diffuse and focal injuries characteristic of moderate and severe TBI. Resting state CBF was quantified in 27 individuals with moderate to severe TBI in the chronic stage, and 22 demographically matched healthy controls. In addition to global CBF reductions in the TBI subjects, more prominent regional hypoperfusion was found in the posterior cingulate cortices, the thalami, and multiple locations in the frontal cortices. Diffuse injury, as assessed by tensor-based morphometry, was mainly associated with reduced CBF in the posterior cingulate cortices and the thalami, where the greatest volume losses were detected. Hypoperfusion in superior and middle frontal cortices, in contrast, was associated with focal lesions. These results suggest that structural lesions, both focal and diffuse, are the main contributors to the absolute CBF alterations seen in chronic TBI, and that CBF may serve as a tool to assess functioning neuronal volume. We also speculate that resting reductions in posterior cingulate perfusion may reflect alterations in the default-mode network, and may contribute to the attentional deficits common in TBI.

  4. The 1H NMR method for the determination of the absolute configuration of 1,2,3-prim,sec,sec-triols.

    PubMed

    Lallana, Enrique; Freire, Félix; Seco, José Manuel; Quiñoa, Emilio; Riguera, Ricardo

    2006-09-28

    The absolute configuration of 1,2,3-prim,sec,sec-triols can be assigned by comparison of the 1H NMR spectra of the tris-(R)- and the tris-(S)-MPA ester derivatives. An experimental demonstration of this correlation with 24 triols of known absolute configuration and a protocol using two parameters-Deltadelta(RS)(H3) and the difference between Deltadelta RS (H2) and Deltadelta RS (H3) = absolute value (Delta(Deltadelta RS))-for its application to the determination of the absolute configuration of other triols are presented.

  5. The use of thermography in early detection of tissue perfusion disorders in rats

    PubMed Central

    Łokaj, Marek; Falkowski, Aleksander; Prowans, Piotr

    2014-01-01

    Introduction Tissue perfusion disorders can be present in various diseases and progress in the form of arterial ischemia or venous stasis with accompanying local changes in temperature. Aim To use of thermography in the diagnostics of early periods of tissue perfusion disorders before the clinical symptoms occur. Material and methods Thirty-two male rats were used. After anesthesia the skin on lower limbs was shaved and femoral vessels of both sides were exposed. In 10 rats the left femoral artery was ligated, in 12 rats the left femoral vein was ligated and in the 10 remaining rats both left femoral vessels were ligated. Thermography of the limbs was performed before the vessels were ligated and after a period of 24 h. The pictures were taken every 5 s during 3 min. Before the measurement, the tissues were cooled down for 20 s with a 5°C water compress. The rate of temperature return to the limbs was evaluated. Results Statistically significant differences were observed after the 24-hour period on the thigh after the ligation of the vein, and on the shank and the foot after ligation of the artery. After the ligature of both vessels, statistically significant differences occurred immediately after their ligature within the thigh and shank and after 24 h on the foot. Conclusions The results show that cameras with an accuracy of 0.05°C can be used to detect tissue perfusion disorders. The special diagnostic value is the ability to detect perfusion disorders before clinical symptoms occur. PMID:25337154

  6. Resting State Brain Function Analysis Using Concurrent BOLD in ASL Perfusion fMRI

    PubMed Central

    Zhu, Senhua; Fang, Zhuo; Hu, Siyuan; Wang, Ze; Rao, Hengyi

    2013-01-01

    The past decade has seen astounding discoveries about resting-state brain activity patterns in normal brain as well as their alterations in brain diseases. While the vast majority of resting-state studies are based on the blood-oxygen-level-dependent (BOLD) functional MRI (fMRI), arterial spin labeling (ASL) perfusion fMRI can simultaneously capture BOLD and cerebral blood flow (CBF) signals, providing a unique opportunity for assessing resting brain functions with concurrent BOLD (ccBOLD) and CBF signals. Before taking that benefit, it is necessary to validate the utility of ccBOLD signal for resting-state analysis using conventional BOLD (cvBOLD) signal acquired without ASL modulations. To address this technical issue, resting cvBOLD and ASL perfusion MRI were acquired from a large cohort (n = 89) of healthy subjects. Four widely used resting-state brain function analyses were conducted and compared between the two types of BOLD signal, including the posterior cingulate cortex (PCC) seed-based functional connectivity (FC) analysis, independent component analysis (ICA), analysis of amplitude of low frequency fluctuation (ALFF), and analysis of regional homogeneity (ReHo). Consistent default mode network (DMN) as well as other resting-state networks (RSNs) were observed from cvBOLD and ccBOLD using PCC-FC analysis and ICA. ALFF from both modalities were the same for most of brain regions but were different in peripheral regions suffering from the susceptibility gradients induced signal drop. ReHo showed difference in many brain regions, likely reflecting the SNR and resolution differences between the two BOLD modalities. The DMN and auditory networks showed highest CBF values among all RSNs. These results demonstrated the feasibility of ASL perfusion MRI for assessing resting brain functions using its concurrent BOLD in addition to CBF signal, which provides a potentially useful way to maximize the utility of ASL perfusion MRI. PMID:23750275

  7. Voxel-by-voxel analysis of brain SPECT perfusion in Fibromyalgia

    NASA Astrophysics Data System (ADS)

    Guedj, Eric; Taïeb, David; Cammilleri, Serge; Lussato, David; de Laforte, Catherine; Niboyet, Jean; Mundler, Olivier

    2007-02-01

    We evaluated brain perfusion SPECT at rest, without noxious stiumuli, in a homogeneous group of hyperalgesic FM patients. We performed a voxel-based analysis in comparison to a control group, matched for age and gender. Under such conditions, we made the assumption that significant cerebral perfusion abnormalities could be demonstrated, evidencing altered cerebral processing associated with spontaneous pain in FM patients. The secondary objective was to study the reversibility and the prognostic value of such possible perfusion abnormalities under specific treatment. Eighteen hyperalgesic FM women (mean age 48 yr; range 25-63 yr; ACR criteria) and 10 healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 ( p<0.05, corrected for multiple comparisons). All brain SPECT were performed before any change was made in therapy in the pain care unit. A second SPECT was performed a month later after specific treatment by Ketamine. Compared to control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. We also found that a medial frontal and anterior cingulate hypoperfusions were highly predictive (PPV=83%; NPV=91%) of non-response on Ketamine, and that only responders showed significant modification of brain perfusion, after treatment. In the present study performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective dimension. As current pharmacological and non-pharmacological therapies act differently on both components of pain, we hypothesize that SPECT could be a valuable and readily available tool to guide individual therapeutic

  8. Motion correction for improving the accuracy of dual-energy myocardial perfusion CT imaging

    NASA Astrophysics Data System (ADS)

    Pack, Jed D.; Yin, Zhye; Xiong, Guanglei; Mittal, Priya; Dunham, Simon; Elmore, Kimberly; Edic, Peter M.; Min, James K.

    2016-03-01

    Coronary Artery Disease (CAD) is the leading cause of death globally [1]. Modern cardiac computed tomography angiography (CCTA) is highly effective at identifying and assessing coronary blockages associated with CAD. The diagnostic value of this anatomical information can be substantially increased in combination with a non-invasive, low-dose, correlative, quantitative measure of blood supply to the myocardium. While CT perfusion has shown promise of providing such indications of ischemia, artifacts due to motion, beam hardening, and other factors confound clinical findings and can limit quantitative accuracy. In this paper, we investigate the impact of applying a novel motion correction algorithm to correct for motion in the myocardium. This motion compensation algorithm (originally designed to correct for the motion of the coronary arteries in order to improve CCTA images) has been shown to provide substantial improvements in both overall image quality and diagnostic accuracy of CCTA. We have adapted this technique for application beyond the coronary arteries and present an assessment of its impact on image quality and quantitative accuracy within the context of dual-energy CT perfusion imaging. We conclude that motion correction is a promising technique that can help foster the routine clinical use of dual-energy CT perfusion. When combined, the anatomical information of CCTA and the hemodynamic information from dual-energy CT perfusion should facilitate better clinical decisions about which patients would benefit from treatments such as stent placement, drug therapy, or surgery and help other patients avoid the risks and costs associated with unnecessary, invasive, diagnostic coronary angiography procedures.

  9. Wavelet transform analysis of skin perfusion during thermal stimulation.

    PubMed

    Bagno, Andrea; Martini, Romeo

    2016-11-25

    This work elucidates the mechanisms of skin microcirculation response to local heating at 44°C in vasculopathic patients. Laser Doppler and tcpO2 were simultaneously acquired. Patients were selected on the basis of tcpO2: Group A <30 mmHg; Group B 30-50 mmHg; Group C >50 mmHg. The wavelet analysis of signal oscillations displays six frequency intervals. Each interval is assigned to a specific cardiovascular activity. The contributions of cardiac, myogenic and neurogenic activities were selectively detected. Thermal stimulation increased relative amplitude in all patients: heart activity by +103.26% in A, +162.84% in B, +454.54% in C; myogenic activity by +52.45% in A, +38.51% in B, +156.19% in C; neurogenic activity +43.36% in A, +74.15% in B, +242.42% in C. Thermal stimulation increased relative power in all patients: heart activity by +365.30% in A, +473.72% in B, +1393.77% in C; myogenic activity by +106.92% in A, +66.03% in B, +380.18% in C; neurogenic activity by +77.00% in A, +162.65% in B, +771.93% in C.This work demonstrates that the spectral analysis allows extracting from Laser Doppler signals more information than that can be gained by solely investigating perfusion values over time.

  10. Repeatability of Cerebral Perfusion Using Dynamic Susceptibility Contrast MRI in Glioblastoma Patients12

    PubMed Central

    Jafari-Khouzani, Kourosh; Emblem, Kyrre E.; Kalpathy-Cramer, Jayashree; Bjørnerud, Atle; Vangel, Mark G.; Gerstner, Elizabeth R.; Schmainda, Kathleen M.; Paynabar, Kamran; Wu, Ona; Wen, Patrick Y.; Batchelor, Tracy; Rosen, Bruce; Stufflebeam, Steven M.

    2015-01-01

    OBJECTIVES This study evaluates the repeatability of brain perfusion using dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a variety of post-processing methods. METHODS Thirty-two patients with newly diagnosed glioblastoma were recruited. On a 3-T MRI using a dual-echo, gradient-echo spin-echo DSC-MRI protocol, the patients were scanned twice 1 to 5 days apart. Perfusion maps including cerebral blood volume (CBV) and cerebral blood flow (CBF) were generated using two contrast agent leakage correction methods, along with testing normalization to reference tissue, and application of arterial input function (AIF). Repeatability of CBV and CBF within tumor regions and healthy tissues, identified by structural images, was assessed with intra-class correlation coefficients (ICCs) and repeatability coefficients (RCs). Coefficients of variation (CVs) were reported for selected methods. RESULTS CBV and CBF were highly repeatable within tumor with ICC values up to 0.97. However, both CBV and CBF showed lower ICCs for healthy cortical tissues (up to 0.83), healthy gray matter (up to 0.95), and healthy white matter (WM; up to 0.93). The values of CV ranged from 6% to 10% in tumor and 3% to 11% in healthy tissues. The values of RC relative to the mean value of measurement within healthy WM ranged from 22% to 42% in tumor and 7% to 43% in healthy tissues. These percentages show how much variation in perfusion parameter, relative to that in healthy WM, we expect to observe to consider it statistically significant. We also found that normalization improved repeatability, but AIF deconvolution did not. CONCLUSIONS DSC-MRI is highly repeatable in high-grade glioma patients. PMID:26055170

  11. Metabolism of 7-ethyoxycoumarin by Isolated Perfused Rainbow Trout Livers

    EPA Science Inventory

    Isolated trout livers were perfused using methods designed to preserve tissue viability and function. Liver performance was evaluated by measuring O2 consumption, vascular resistance, K+ leakage, glucose flux, lactate flux, alanine aminotransferase leakage, and metabolic clearanc...

  12. Hemangioma of the tongue demonstrating a perfusion blood pool mismatch

    SciTech Connect

    Front, D.; Groshar, D.; Israel, O.; Robinson, E.

    1986-02-01

    Perfusion blood pool mismatch using Tc-99m labeled red blood cells (RBCs) in a hemangioma of the tongue is described. The method is useful in the evaluation of size of the residual blood pool after irradiation of the tumor.

  13. Sexual Values of 783 Undergraduates

    ERIC Educational Resources Information Center

    Richey, Emily; Knox, David; Zusman, Marty

    2009-01-01

    The sexual values of absolutism (abstinence until marriage), relativism (sexual decisions made in reference to the nature of the relationship), and hedonism ("if it feels good, do it") were assessed in a convenience sample of 783 undergraduate students at a large southeastern university. Results revealed that relativism (62.1%) was the predominate…

  14. Arterial Perfusion Imaging-Defined Subvolume of Intrahepatic Cancer

    PubMed Central

    Wang, Hesheng; Farjam, Reza; Feng, Mary; Hussain, Hero; Ten Haken, Randall K.; Lawrence, Theodore S.; Cao, Yue

    2014-01-01

    Purpose To assess whether an increase in a subvolume of intrahepatic tumor with elevated arterial perfusion during radiation therapy (RT) predicts tumor progression post RT. Methods and Materials Twenty patients with unresectable intrahepatic cancers undergoing RT were enrolled in a prospective IRB-approved study. Dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) were performed prior to RT (pre-RT), after delivering ~60% of the planned dose (mid-RT) and one month after completion of RT to quantify hepatic arterial perfusion. The arterial perfusions of the tumors at pre-RT were clustered into low-normal and elevated perfusion by a fuzzy clustering-based method, and the tumor subvolumes with elevated arterial perfusion were extracted from the hepatic arterial perfusion images. The percentage changes in the tumor subvolumes and means of arterial perfusion over the tumors from pre-RT to mid-RT were evaluated for predicting tumor progression post-RT. Results Of the 24 tumors, 6 tumors in 5 patients progressed 5–21 months after RT completion. Neither tumor volumes nor means of tumor arterial perfusion at pre-RT were predictive of treatment outcome. The mean arterial perfusion over the tumors increased significantly at mid-RT in progressive tumors comparing to the responsive ones (p=0.006). From pre-RT to mid-RT, the responsive tumors had a decrease in the tumor subvolumes with elevated arterial perfusion (median: −14%, range: −75% – 65%), while the progressing tumors had an increase of the subvolumes (median: 57%, range: −7% – 165%) (p=0.003). Receiver operating characteristic (ROC) analysis of the percentage change in the subvolume for predicting tumor progression post-RT had an area under the curve (AUC) of 0.90. Conclusion The increase in the subvolume of the intrahepatic tumor with elevated arterial perfusion during RT has the potential to be a predictor for tumor progression post-RT. The tumor subvolume could be a radiation boost candidate

  15. Determination of Absolute Zero Using a Computer-Based Laboratory

    ERIC Educational Resources Information Center

    Amrani, D.

    2007-01-01

    We present a simple computer-based laboratory experiment for evaluating absolute zero in degrees Celsius, which can be performed in college and undergraduate physical sciences laboratory courses. With a computer, absolute zero apparatus can help demonstrators or students to observe the relationship between temperature and pressure and use…

  16. A Global Forecast of Absolute Poverty and Employment.

    ERIC Educational Resources Information Center

    Hopkins, M. J. D.

    1980-01-01

    Estimates are made of absolute poverty and employment under the hypothesis that existing trends continue. Concludes that while the number of people in absolute poverty is not likely to decline by 2000, the proportion will fall. Jobs will have to grow 3.9% per year in developing countries to achieve full employment. (JOW)

  17. Absolute Humidity and the Seasonality of Influenza (Invited)

    NASA Astrophysics Data System (ADS)

    Shaman, J. L.; Pitzer, V.; Viboud, C.; Grenfell, B.; Goldstein, E.; Lipsitch, M.

    2010-12-01

    Much of the observed wintertime increase of mortality in temperate regions is attributed to seasonal influenza. A recent re-analysis of laboratory experiments indicates that absolute humidity strongly modulates the airborne survival and transmission of the influenza virus. Here we show that the onset of increased wintertime influenza-related mortality in the United States is associated with anomalously low absolute humidity levels during the prior weeks. We then use an epidemiological model, in which observed absolute humidity conditions temper influenza transmission rates, to successfully simulate the seasonal cycle of observed influenza-related mortality. The model results indicate that direct modulation of influenza transmissibility by absolute humidity alone is sufficient to produce this observed seasonality. These findings provide epidemiological support for the hypothesis that absolute humidity drives seasonal variations of influenza transmission in temperate regions. In addition, we show that variations of the basic and effective reproductive numbers for influenza, caused by seasonal changes in absolute humidity, are consistent with the general timing of pandemic influenza outbreaks observed for 2009 A/H1N1 in temperate regions. Indeed, absolute humidity conditions correctly identify the region of the United States vulnerable to a third, wintertime wave of pandemic influenza. These findings suggest that the timing of pandemic influenza outbreaks is controlled by a combination of absolute humidity conditions, levels of susceptibility and changes in population mixing and contact rates.

  18. Novalis' Poetic Uncertainty: A "Bildung" with the Absolute

    ERIC Educational Resources Information Center

    Mika, Carl

    2016-01-01

    Novalis, the Early German Romantic poet and philosopher, had at the core of his work a mysterious depiction of the "absolute." The absolute is Novalis' name for a substance that defies precise knowledge yet calls for a tentative and sensitive speculation. How one asserts a truth, represents an object, and sets about encountering things…

  19. Noninvasive absolute cerebral oximetry with frequency-domain near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Hallacoglu, Bertan

    Near-infrared spectroscopy (NIRS) measurements of absolute concentrations of oxy-hemoglobin and deoxy-hemoglobin in the human brain can provide critical information about cerebral physiology in terms of cerebral blood volume, blood flow, oxygen delivery, and metabolic rate of oxygen. We developed several frequency domain NIRS data acquisition and analysis methods aimed at absolute measurements of hemoglobin concentration and saturation in cerebral tissue of adult human subjects. Extensive experimental investigations were carried out in various homogenous and two-layered tissue-mimicking phantoms, and biological tissues. The advantages and limitations of commonly used homogenous models and inversion strategies were thoroughly investigated. Prior to human subjects, extensive studies were carried out in in vivo animal models. In rabbits, absolute hemoglobin oxygen desaturation was shown to depend strongly on surgically induced testicular torsion. Methods developed in this study were then adapted for measurements in the rat brain. Absolute values were demonstrated to discern cerebrovascular impairment in a rat model of diet-induced vascular cognitive impairment. These results facilitated the development of clinically useful optical measures of cerebrovascular health. In a large group of human subjects, employing a homogeneous model for absolute measurements was shown to be reliable and robust. However, it was also shown to be limited due to the relatively thick extracerebral tissue. The procedure we develop in this work and the thesis thereof performs a nonlinear inversion procedure with six unknown parameters with no other prior knowledge for the retrieval of the optical coefficients and top layer thickness with high accuracy on two-layered media. Our absolute measurements of cerebral hemoglobin concentration and saturation are based on the discrimination of extracerebral and cerebral tissue layers, and they can enhance the impact of NIRS for cerebral hemodynamics and

  20. Perfusion Electronic Record Documentation Using Epic Systems Software.

    PubMed

    Steffens, Thomas G; Gunser, John M; Saviello, George M

    2015-12-01

    This paper describes the design and use of Epic Systems software for documentation of perfusion activities as part of the patient electronic medical record. The University of Wisconsin Hospital and Clinics adapted the Anesthesia software module and developed an integrated perfusion/anesthesia record for the documentation of cardiac and non-cardiac surgical procedures. This project involved multiple committees, approvals, and training to successfully implement. This article will describe our documentation options, concepts, design, challenges, training, and implementation during our initial experience.

  1. Perfusion characteristics of preserved canine kidneys subjected to warm ischaemia.

    PubMed

    Modgill, V K; Wiggins, P A; Giles, G R

    1978-02-01

    Canine kidneys were subjected to 0, 15 or 30 min of warm ischaemia followed by 24 hours preservation by perfusion. Changes in perfusate concentration of acid radicles, lactate, free fatty acid and lactice dehydrogenase were assessed at 1 hour and 24 hours. With the exception of LDH concentration at 1 hour, no single parameter was capable of detecting kidneys which were so damaged as to be non-life supporting.

  2. Assessment of lung tumor response by perfusion CT.

    PubMed

    Coche, E

    2013-01-01

    Perfusion CT permits evaluation of lung cancer angiogenesis and response to therapy by demonstrating alterations in lung tumor vascularity. It is advocated that perfusion CT performed shortly after initiating therapy may provide a better evaluation of physiological changes rather than the conventional size assessment obtained with RECIST. The radiation dose,the volume of contrast medium delivered to the patient and the reproducibility of blood flow parameters remain an issue for this type of investigation.

  3. Correlation between CT Perfusion Parameters and Microvessel Density and Vascular Endothelial Growth Factor in Adrenal Tumors

    PubMed Central

    Wang, Xifu; Bai, Renju; Li, Yajun; Zhao, Jinkun

    2013-01-01

    We evaluated the correlation between computed tomography (CT) perfusion parameters and markers of angiogenesis in adrenal adenomas and non-adenomas to determine if perfusion CT can be used to distinguish between them. Thirty-four patients with pathologically-confirmed adrenal tumors (17 adenomas, 17 non-adenomas) received CT perfusion imaging before surgery. CT perfusion parameters (blood flow [BF], blood volume [BV], mean transit time [MTT], and permeability surface area product [PS]) were calculated. Tumor tissue sections were examined with immunohistochemical methods for vascular endothelial growth factor (VEGF) expression and microvessel density (MVD). The mean age of the 34 patients was 43 years. The median BV was significantly higher in adenomas than in non-adenomas [12.3 ml/100 g, inter-quartile range (IQR): 10.4 to 16.5 ml/100 g vs. 8.8 ml/100 g, IQR: 3.3 to 9.4 ml/100 g, p = 0.001]. Differences in BF, MTT, and PS parameter values between adenomas and non-adenomas were not significant (p>0.05). The mean MVD was significantly higher in adenomas compared to non-adenomas (98.5±28.5 vs. 53.5±27.0, p<0.0001). Adenomas also expressed significantly higher median VEGF than non-adenomas (65%, IQR: 50 to 79% vs. 45%, IQR: 35 to 67%, p = 0.02). A moderately strong correlation between BF and VEGF (r = 0.53, p = 0.03) and between BV and MVD among adenomas (r = 0.57, p = 0.02) exist. Morphology, MVD, and VEGF expression in adenomas differ significantly from non-adenomas. Of the CT perfusion parameters examined, both BF and BV correlate with MVD, but only BF correlates with VEGF, and only in adenomas. The significant difference in BV suggests that BV may be used to differentiate adenomas from non-adenomas. However, the small difference in BV shows that it may only be possible to use BV to identify adenomas vs. non-adenomas at extreme BV values. PMID:24260316

  4. Absolute radiometric calibration of advanced remote sensing systems

    NASA Technical Reports Server (NTRS)

    Slater, P. N.

    1982-01-01

    The distinction between the uses of relative and absolute spectroradiometric calibration of remote sensing systems is discussed. The advantages of detector-based absolute calibration are described, and the categories of relative and absolute system calibrations are listed. The limitations and problems associated with three common methods used for the absolute calibration of remote sensing systems are addressed. Two methods are proposed for the in-flight absolute calibration of advanced multispectral linear array systems. One makes use of a sun-illuminated panel in front of the sensor, the radiance of which is monitored by a spectrally flat pyroelectric radiometer. The other uses a large, uniform, high-radiance reference ground surface. The ground and atmospheric measurements required as input to a radiative transfer program to predict the radiance level at the entrance pupil of the orbital sensor are discussed, and the ground instrumentation is described.

  5. A developmental study of latent absolute pitch memory.

    PubMed

    Jakubowski, Kelly; Müllensiefen, Daniel; Stewart, Lauren

    2017-03-01

    The ability to recall the absolute pitch level of familiar music (latent absolute pitch memory) is widespread in adults, in contrast to the rare ability to label single pitches without a reference tone (overt absolute pitch memory). The present research investigated the developmental profile of latent absolute pitch (AP) memory and explored individual differences related to this ability. In two experiments, 288 children from 4 to12 years of age performed significantly above chance at recognizing the absolute pitch level of familiar melodies. No age-related improvement or decline, nor effects of musical training, gender, or familiarity with the stimuli were found in regard to latent AP task performance. These findings suggest that latent AP memory is a stable ability that is developed from as early as age 4 and persists into adulthood.

  6. Demonstrating the error budget for the climate absolute radiance and refractivity observatory through solar irradiance measurements (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Thome, Kurtis J.; McCorkel, Joel; Angal, Amit

    2016-09-01

    The goal of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is to provide high-accuracy data for evaluation of long-term climate change trends. Essential to the CLARREO project is demonstration of SI-traceable, reflected measurements that are a factor of 10 more accurate than current state-of-the-art sensors. The CLARREO approach relies on accurate, monochromatic absolute radiance calibration in the laboratory transferred to orbit via solar irradiance knowledge. The current work describes the results of field measurements with the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) that is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. Recent measurements of absolute spectral solar irradiance using SOLARIS are presented. The ground-based SOLARIS data are corrected to top-of-atmosphere values using AERONET data collected within 5 km of the SOLARIS operation. The SOLARIS data are converted to absolute irradiance using laboratory calibrations based on the Goddard Laser for Absolute Measurement of Radiance (GLAMR). Results are compared to accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

  7. Quantitative measurement of tissue perfusion and diffusion in vivo.

    PubMed

    Chenevert, T L; Pipe, J G; Williams, D M; Brunberg, J A

    1991-01-01

    Magnetic resonance imaging techniques designed for sensitivity to microscopic motions of water diffusion and blood flow in the capillary network are also exceptionally sensitive to bulk motion properties of the tissue, which may lead to contrast artifact and large quantitative errors. The magnitude of bulk motion error that exists in human brain perfusion/diffusion imaging and the inability of cardiac gating to adequately control this motion are demonstrated by direct measurement of phase stability of voxels localized in the brain. Two methods are introduced to reduce bulk motion phase error. The first, a postprocessing phase correction algorithm, reduces coarse phase error but is inadequate by itself for quantitative perfusion/diffusion MRI. The second method employs orthogonal slice selection gradients to define a column of tissue in the object, from which echoes may be combined in a phase-insensitive manner to measure more reliably the targeted signal attenuation. Applying this acquisition technique and a simplistic model of perfusion and diffusion signal attenuations yields an estimated perfusion fraction of 3.4 +/- 1.1% and diffusion coefficient of 1.1 +/- 0.2 x 10(-5) cm2/s in the white matter of one normal volunteer. Successful separation of perfusion and diffusion effects by this technique is supported in a dynamic study of calf muscle. Periods of normal blood flow, low flow, and reactive hyperemia are clearly distinguished in the quantitative perfusion results, whereas measured diffusion remained nearly constant.

  8. Goal-directed-perfusion in neonatal aortic arch surgery

    PubMed Central

    Purbojo, Ariawan; Muench, Frank; Juengert, Joerg; Rueffer, André

    2016-01-01

    Reduction of mortality and morbidity in congenital cardiac surgery has always been and remains a major target for the complete team involved. As operative techniques are more and more standardized and refined, surgical risk and associated complication rates have constantly been reduced to an acceptable level but are both still present. Aortic arch surgery in neonates seems to be of particular interest, because perfusion techniques differ widely among institutions and an ideal form of a so called “total body perfusion (TBP)” is somewhat difficult to achieve. Thus concepts of deep hypothermic circulatory arrest (DHCA), regional cerebral perfusion (RCP/with cardioplegic cardiac arrest or on the perfused beating heart) and TBP exist in parallel and all carry an individual risk for organ damage related to perfusion management, chosen core temperature and time on bypass. Patient safety relies more and more on adequate end organ perfusion on cardiopulmonary bypass, especially sensitive organs like the brain, heart, kidney, liver and the gut, whereby on adequate tissue protection, temperature management and oxygen delivery should be visualized and monitored. PMID:27709094

  9. Quantitative Analysis of Peripheral Tissue Perfusion Using Spatiotemporal Molecular Dynamics

    PubMed Central

    Lee, Jungsul; Koh, Gou Young; Kwon, Kihwan; Choi, Chulhee

    2009-01-01

    Background Accurate measurement of peripheral tissue perfusion is challenging but necessary to diagnose peripheral vascular insufficiency. Because near infrared (NIR) radiation can penetrate relatively deep into tissue, significant attention has been given to intravital NIR fluorescence imaging. Methodology/Principal Findings We developed a new optical imaging-based strategy for quantitative measurement of peripheral tissue perfusion by time-series analysis of local pharmacokinetics of the NIR fluorophore, indocyanine green (ICG). Time-series NIR fluorescence images were obtained after injecting ICG intravenously in a murine hindlimb ischemia model. Mathematical modeling and computational simulations were used for translating time-series ICG images into quantitative pixel perfusion rates and a perfusion map. We could successfully predict the prognosis of ischemic hindlimbs based on the perfusion profiles obtained immediately after surgery, which were dependent on the preexisting collaterals. This method also reflected increases in perfusion and improvements in prognosis of ischemic hindlimbs induced by treatment with vascular endothelial growth factor and COMP-angiopoietin-1. Conclusions/Significance We propose that this novel NIR-imaging-based strategy is a powerful tool for biomedical studies related to the evaluation of therapeutic interventions directed at stimulating angiogenesis. PMID:19169354

  10. The relationship between ischemia-induced left ventricular dysfunction, coronary flow reserve, and coronary steal on regadenoson stress-gated 82Rb PET myocardial perfusion imaging

    PubMed Central

    Van Tosh, Andrew; Votaw, John R.; Reichek, Nathaniel; Palestro, Christopher J.; Nichols, Kenneth J.

    2014-01-01

    Background Gated rubidium-82 (82Rb) positron emission tomography (PET) imaging studies are acquired both at rest and during pharmacologic stress. Stress-induced ischemic left ventricular dysfunction (LVD) can produce a significant decrease in left ventricular ejection fraction (LVEF) from rest to stress. We determined the prevalence on PET of stress LVD with reduced ejection fraction (EF) and its association with absolute global and regional coronary flow reserve (CFR), and with relative perfusion defect summed difference score (SDS). Methods and Results We studied 205 patients with known or suspected coronary disease (120 M, 75 F, age 69 ± 13 years) who had clinically indicated rest/regadenoson stress 82Rb PET/CT studies. Data were acquired in dynamic gated list mode. Global and 17-segment regional CFR values were computed from first-pass flow data using a 2-compartment model and factor analysis applied to auto-generated time-activity curves. Rest and stress LVEF and SDS were quantified from gated equilibrium myocardial perfusion tomograms using Emory Cardiac Toolbox software. LVD was defined as a change in LVEF of ≤−5% from rest to stress. A subgroup of 109 patients also had coronary angiography. Stress LVD developed in 32 patients (16%), with mean EF change of −10 ± 5%, vs +6 ± 7% for patients without LVD (P < .0001). EF was similar at rest in patients with and without stress LVD (57 ± 18% vs 56 ± 16%, P = .63), but lower during stress for patients with LVD (47 ± 20% vs 61 ± 16%, P = .0001). CFR was significantly lower in patients wi