Science.gov

Sample records for absolute perfusion values

  1. Easy Absolute Values? Absolutely

    ERIC Educational Resources Information Center

    Taylor, Sharon E.; Mittag, Kathleen Cage

    2015-01-01

    The authors teach a problem-solving course for preservice middle-grades education majors that includes concepts dealing with absolute-value computations, equations, and inequalities. Many of these students like mathematics and plan to teach it, so they are adept at symbolic manipulations. Getting them to think differently about a concept that they…

  2. Teaching Absolute Value Meaningfully

    ERIC Educational Resources Information Center

    Wade, Angela

    2012-01-01

    What is the meaning of absolute value? And why do teachers teach students how to solve absolute value equations? Absolute value is a concept introduced in first-year algebra and then reinforced in later courses. Various authors have suggested instructional methods for teaching absolute value to high school students (Wei 2005; Stallings-Roberts…

  3. Be Resolute about Absolute Value

    ERIC Educational Resources Information Center

    Kidd, Margaret L.

    2007-01-01

    This article explores how conceptualization of absolute value can start long before it is introduced. The manner in which absolute value is introduced to students in middle school has far-reaching consequences for their future mathematical understanding. It begins to lay the foundation for students' understanding of algebra, which can change…

  4. Inequalities, Absolute Value, and Logical Connectives.

    ERIC Educational Resources Information Center

    Parish, Charles R.

    1992-01-01

    Presents an approach to the concept of absolute value that alleviates students' problems with the traditional definition and the use of logical connectives in solving related problems. Uses a model that maps numbers from a horizontal number line to a vertical ray originating from the origin. Provides examples solving absolute value equations and…

  5. Investigating Absolute Value: A Real World Application

    ERIC Educational Resources Information Center

    Kidd, Margaret; Pagni, David

    2009-01-01

    Making connections between various representations is important in mathematics. In this article, the authors discuss the numeric, algebraic, and graphical representations of sums of absolute values of linear functions. The initial explanations are accessible to all students who have experience graphing and who understand that absolute value simply…

  6. Solving Absolute Value Equations Algebraically and Geometrically

    ERIC Educational Resources Information Center

    Shiyuan, Wei

    2005-01-01

    The way in which students can improve their comprehension by understanding the geometrical meaning of algebraic equations or solving algebraic equation geometrically is described. Students can experiment with the conditions of the absolute value equation presented, for an interesting way to form an overall understanding of the concept.

  7. Teaching Absolute Value Inequalities to Mature Students

    ERIC Educational Resources Information Center

    Sierpinska, Anna; Bobos, Georgeana; Pruncut, Andreea

    2011-01-01

    This paper gives an account of a teaching experiment on absolute value inequalities, whose aim was to identify characteristics of an approach that would realize the potential of the topic to develop theoretical thinking in students enrolled in prerequisite mathematics courses at a large, urban North American university. The potential is…

  8. The absolute CBF response to activation is preserved during elevated perfusion: Implications for neurovascular coupling measures

    PubMed Central

    Whittaker, Joseph R.; Driver, Ian D.; Bright, Molly G.; Murphy, Kevin

    2016-01-01

    Functional magnetic resonance imaging (fMRI) techniques in which the blood oxygenation level dependent (BOLD) and cerebral blood flow (CBF) response to a neural stimulus are measured, can be used to estimate the fractional increase in the cerebral metabolic rate of oxygen consumption (CMRO2) that accompanies evoked neural activity. A measure of neurovascular coupling is obtained from the ratio of fractional CBF and CMRO2 responses, defined as n, with the implicit assumption that relative rather than absolute changes in CBF and CMRO2 adequately characterise the flow-metabolism response to neural activity. The coupling parameter n is important in terms of its effect on the BOLD response, and as potential insight into the flow-metabolism relationship in both normal and pathological brain function. In 10 healthy human subjects, BOLD and CBF responses were measured to test the effect of baseline perfusion (modulated by a hypercapnia challenge) on the coupling parameter n during graded visual stimulation. A dual-echo pulsed arterial spin labelling (PASL) sequence provided absolute quantification of CBF in baseline and active states as well as relative BOLD signal changes, which were used to estimate CMRO2 responses to the graded visual stimulus. The absolute CBF response to the visual stimuli were constant across different baseline CBF levels, meaning the fractional CBF responses were reduced at the hyperperfused baseline state. For the graded visual stimuli, values of n were significantly reduced during hypercapnia induced hyperperfusion. Assuming the evoked neural responses to the visual stimuli are the same for both baseline CBF states, this result has implications for fMRI studies that aim to measure neurovascular coupling using relative changes in CBF. The coupling parameter n is sensitive to baseline CBF, which would confound its interpretation in fMRI studies where there may be significant differences in baseline perfusion between groups. The absolute change in

  9. A Conceptual Approach to Absolute Value Equations and Inequalities

    ERIC Educational Resources Information Center

    Ellis, Mark W.; Bryson, Janet L.

    2011-01-01

    The absolute value learning objective in high school mathematics requires students to solve far more complex absolute value equations and inequalities. When absolute value problems become more complex, students often do not have sufficient conceptual understanding to make any sense of what is happening mathematically. The authors suggest that the…

  10. Using, Seeing, Feeling, and Doing Absolute Value for Deeper Understanding

    ERIC Educational Resources Information Center

    Ponce, Gregorio A.

    2008-01-01

    Using sticky notes and number lines, a hands-on activity is shared that anchors initial student thinking about absolute value. The initial point of reference should help students successfully evaluate numeric problems involving absolute value. They should also be able to solve absolute value equations and inequalities that are typically found in…

  11. Absolute concentration determination of phosphorus metabolites in the Langendorff-perfused rabbit heart by phosphorus-31 nuclear magnetic resonance

    SciTech Connect

    Gard, J.K.

    1984-01-01

    The concentrations of mobile high energy phosphorus metabolites and intracellular pH of Langendorff-perfused rabbit heart have been determined under control and reduced flow conditions. Absolute concentration determination was accomplished by Lorentzian lineshape analysis after development of hexachlorocyclotriphosphazene as an external intensity standard. Hearts were demonstrated to be biochemically and physiologically competent during control perfusion periods and compromised during reduced flow conditions by independent hemodynamic and metabolic measurements coincident with the NMR experiment. Reduction in perfusate flow from 20 mL/min to 5.0 mL/min (25% flow) or 2.5 mL/min (12.5% flow) demonstrated a fall in phosphocreatine and adenosine triphosphate concentrations, a rise in cytosolic inorganic phosphate concentrations, and drops in pH. Subsequent recovery upon reflow was observed. The derived values for the free concentration of ADP were very close to the reported values of the Michaelis constant for respiratory stimulation, implicating a regulatory role for this molecule in cellular respiration. Strong evidence that the creating kinase reaction was in equilibrium in the 25% flow study was seen. The NMR observable correlated closely with myocardial performance and biochemical indices of metabolic function, and supported the use of phosphocreatine as an indicator of current metabolic integrity.

  12. Absolutely relative or relatively absolute: violations of value invariance in human decision making.

    PubMed

    Teodorescu, Andrei R; Moran, Rani; Usher, Marius

    2016-02-01

    Making decisions based on relative rather than absolute information processing is tied to choice optimality via the accumulation of evidence differences and to canonical neural processing via accumulation of evidence ratios. These theoretical frameworks predict invariance of decision latencies to absolute intensities that maintain differences and ratios, respectively. While information about the absolute values of the choice alternatives is not necessary for choosing the best alternative, it may nevertheless hold valuable information about the context of the decision. To test the sensitivity of human decision making to absolute values, we manipulated the intensities of brightness stimuli pairs while preserving either their differences or their ratios. Although asked to choose the brighter alternative relative to the other, participants responded faster to higher absolute values. Thus, our results provide empirical evidence for human sensitivity to task irrelevant absolute values indicating a hard-wired mechanism that precedes executive control. Computational investigations of several modelling architectures reveal two alternative accounts for this phenomenon, which combine absolute and relative processing. One account involves accumulation of differences with activation dependent processing noise and the other emerges from accumulation of absolute values subject to the temporal dynamics of lateral inhibition. The potential adaptive role of such choice mechanisms is discussed. PMID:26022836

  13. Supplementary and Enrichment Series: Absolute Value. Teachers' Commentary. SP-25.

    ERIC Educational Resources Information Center

    Bridgess, M. Philbrick, Ed.

    This is one in a series of manuals for teachers using SMSG high school supplementary materials. The pamphlet includes commentaries on the sections of the student's booklet, answers to the exercises, and sample test questions. Topics covered include addition and multiplication in terms of absolute value, graphs of absolute value in the Cartesian…

  14. Supplementary and Enrichment Series: Absolute Value. SP-24.

    ERIC Educational Resources Information Center

    Bridgess, M. Philbrick, Ed.

    This is one in a series of SMSG supplementary and enrichment pamphlets for high school students. This series is designed to make material for the study of topics of special interest to students readily accessible in classroom quantity. Topics covered include absolute value, addition and multiplication in terms of absolute value, graphs of absolute…

  15. The prognostic value of non-perfusion variables obtained during vasodilator stress myocardial perfusion imaging.

    PubMed

    Bajaj, Navkaranbir S; Singh, Siddharth; Farag, Ayman; El-Hajj, Stephanie; Heo, Jack; Iskandrian, Ami E; Hage, Fadi G

    2016-06-01

    Myocardial perfusion imaging (MPI) is an established diagnostic test that provides useful prognostic data in patients with known or suspected coronary artery disease. In more than half of the patients referred for stress testing, vasodilator stress is used in lieu of exercise. Unlike exercise, vasodilator stress does not provide information on exercise and functional capacity, heart rate recovery, and chronotropy, and ECG changes are less frequent. These non-perfusion data provide important prognostic and patient management information. Further, event rates in patients undergoing vasodilator MPI are higher than in those undergoing exercise MPI and even in those with normal images probably due to higher pretest risk. However, there are a number of non-perfusion variables that are obtained during vasodilator stress testing, which have prognostic relevance but their use has not been well emphasized. The purpose of this review is to summarize the prognostic values of these non-perfusion data obtained during vasodilator MPI. PMID:26940574

  16. Absolute Value Boundedness, Operator Decomposition, and Stochastic Media and Equations

    NASA Technical Reports Server (NTRS)

    Adomian, G.; Miao, C. C.

    1973-01-01

    The research accomplished during this period is reported. Published abstracts and technical reports are listed. Articles presented include: boundedness of absolute values of generalized Fourier coefficients, propagation in stochastic media, and stationary conditions for stochastic differential equations.

  17. Prognostic value of normal regadenoson stress perfusion cardiovascular magnetic resonance

    PubMed Central

    2013-01-01

    Background Regadenoson is a vasodilator stress agent that selectively activates the A2A receptor. Compared to adenosine, regadenoson is easier to administer and results in fewer side effects. Although extensively studied in patients undergoing nuclear perfusion imaging (MPI), its use for perfusion cardiovascular magnetic resonance (CMR) is not well described. The aim of this study was to determine the prognostic value of a normal regadenoson perfusion CMR in patients with known or suspected coronary artery disease. Methods Patients with known or suspected coronary artery disease were prospectively enrolled to receive perfusion CMR (Philips 1.5 T) with regadenoson. Three short-axis slices of the left ventricle (LV) were obtained during first pass of contrast using a hybrid GRE-EPI pulse sequence (0.075 mmol/kg Gadolinium-DTPA-BMA at 4 ml/sec). Imaging was performed 1 minute after injection of regadenoson (0.4 mg) and repeated 15 minutes after reversal of hyperemia with aminophylline (125 mg). Perfusion defects were documented if they persisted for ≥2 frames after peak enhancement of the LV cavity. CMR was considered abnormal if there was a resting wall motion abnormality, decreased LVEF (<40%), presence of LGE, or the presence of a perfusion defect during hyperemia. All patients were followed for a minimum of 1 year for major adverse cardiovascular event (MACE) defined as coronary revascularization, non-fatal myocardial infarction, and cardiovascular death. Results 149 patients were included in the final analysis. Perfusion defects were noted in 43/149 (29%) patients; 59/149 (40%) had any abnormality on CMR. During the mean follow-up period of 24 ± 9 months, 17/149 (11.4%) patients experienced MACE. The separation in the survival distributions for those with perfusion defects and those without perfusion defects was highly significant (log-rank p = 0.0001). When the absence of perfusion defects was added to the absence of other resting CMR

  18. An improved generalized Newton method for absolute value equations.

    PubMed

    Feng, Jingmei; Liu, Sanyang

    2016-01-01

    In this paper, we suggest and analyze an improved generalized Newton method for solving the NP-hard absolute value equations [Formula: see text] when the singular values of A exceed 1. We show that the global and local quadratic convergence of the proposed method. Numerical experiments show the efficiency of the method and the high accuracy of calculation. PMID:27462490

  19. Absolute Value Inequalities: High School Students' Solutions and Misconceptions

    ERIC Educational Resources Information Center

    Almog, Nava; Ilany, Bat-Sheva

    2012-01-01

    Inequalities are one of the foundational subjects in high school math curricula, but there is a lack of academic research into how students learn certain types of inequalities. This article fills part of the research gap by presenting the findings of a study that examined high school students' methods of approaching absolute value inequalities,…

  20. Invalid phase values removal method for absolute phase recovery.

    PubMed

    Lu, Jin; Mo, Rong; Sun, Huibin; Chang, Zhiyong; Zhao, Xiaxia

    2016-01-10

    A novel approach is presented for more effectively removing invalid phase values in absolute phase recovery. The approach is based on a detailed study involving the types and cases of invalid phase values. Meanwhile, some commonalities of the existing removal algorithms also are thoroughly analyzed. It is well known that rough absolute phase and fringe order maps can very easily be obtained by temporal phase unwrapping techniques. After carefully analyzing the components and fringe order distribution of the rough fringe order map, the proposed method chiefly adopts an entirely new strategy to refine a pure fringe order map. The strategy consists of three parts: (1) the square of an image gradient, (2) subregion areas of the binary image, and (3) image decomposition and composition. In combination with the pure fringe order map and a removal criterion, the invalid phase values can be identified and filtered out from the rough absolute phase map. This new strategy not only gets rid of the limitations of traditional removal methods but also has a two-fold function. The paper also offers different metrics from the experiment to evaluate the quality of the final absolute phase. In contrast with other removal methods, experimental results have verified the feasibility, effectiveness, and superiority of the proposed method. PMID:26835776

  1. Prognostic value of quantitative high-speed myocardial perfusion imaging

    PubMed Central

    Nakazato, Ryo; Berman, Daniel S.; Gransar, Heidi; Hyun, Mark; Miranda-Peats, Romalisa; Kite, Faith C.; Hayes, Sean W.; Thomson, Louise E.J.; Friedman, John D.; Rozanski, Alan; Slomka, Piotr J.

    2012-01-01

    Background Most studies have reported using semi-quantitative analysis to assess the prognostic utility of SPECT myocardial perfusion imaging (MPI). Thus we studied the prognostic value of fully automated quantitative analysis software applied to new solid-state, high-speed (HS) SPECT-MPI. Methods 1613 consecutive patients undergoing exercise or adenosine HS-MPI were followed for 2.6±0.5 years for all-cause mortality (ACM). Automated quantitative software was used for assessing stress total perfusion deficit (sTPD) and was compared to semi-quantitative visual analysis. MPI was characterized as 0% (normal); 1–4% (minimal perfusion defect); 5–10% (mildly abnormal); and >10% (moderately/severely abnormal). Results During follow-up, 79 patients died (4.9%). Annualized ACM increased with progressively increasing sTPD; 0% (0.87%), 1–4% (1.94%), 5–10% (3.10%) and >10% (5.33%) (log-rank p<0.0001). While similar overall findings were observed with visual analysis, only sTPD demonstrated increased risk in patients with minimal perfusion defects. In multivariable analysis, sTPD >10% was a mortality predictor (HR 3.03, 95% CI 1.30–7.09, p=0.01). Adjusted mortality rate was substantial in adenosine MPI, but low in exercise MPI (9.0% versus 1.0%, p<0.0001). Conclusions By quantitative analysis, ACM increases with increasing perfusion abnormality among patients undergoing stress HS-MPI. These findings confirm previous results obtained with visual analysis using conventional Anger camera imaging systems. PMID:23065414

  2. EFFECT ON PERFUSION VALUES OF SAMPLING INTERVAL OF CT PERFUSION ACQUISITIONS IN NEUROENDOCRINE LIVER METASTASES AND NORMAL LIVER

    PubMed Central

    Ng, Chaan S.; Hobbs, Brian P.; Wei, Wei; Anderson, Ella F.; Herron, Delise H.; Yao, James C.; Chandler, Adam G.

    2014-01-01

    Objective To assess the effects of sampling interval (SI) of CT perfusion acquisitions on CT perfusion values in normal liver and liver metastases from neuroendocrine tumors. Methods CT perfusion in 16 patients with neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction, for tumor and normal liver. CT perfusion values for the reference sampling interval of 0.5s (SI0.5) were compared with those of SI datasets of 1s, 2s, 3s and 4s, using mixed-effects model analyses. Results Increases in SI beyond 1s were associated with significant and increasing departures of CT perfusion parameters from reference values at SI0.5 (p≤0.0009). CT perfusion values deviated from reference with increasing uncertainty with increasing SIs. Findings for normal liver were concordant. Conclusion Increasing SIs beyond 1s yield significantly different CT perfusion parameter values compared to reference values at SI0.5. PMID:25626401

  3. Absolute quantification of cerebral blood flow in neurologically normal volunteers: dynamic-susceptibility contrast MRI-perfusion compared with computed tomography (CT)-perfusion.

    PubMed

    Ziegelitz, Doerthe; Starck, Göran; Mikkelsen, Irene K; Tullberg, Mats; Edsbagge, Mikael; Wikkelsö, Carsten; Forssell-Aronson, Eva; Holtås, Stig; Knutsson, Linda

    2009-07-01

    To improve the reproducibility of arterial input function (AIF) registration and absolute cerebral blood flow (CBF) quantification in dynamic-susceptibility MRI-perfusion (MRP) at 1.5T, we rescaled the AIF by use of a venous output function (VOF). We compared CBF estimates of 20 healthy, elderly volunteers, obtained by computed tomography (CT)-perfusion (CTP) and MRP on two consecutive days. MRP, calculated without the AIF correction, did not result in any significant correlation with CTP. The rescaled MRP showed fair to moderate correlation with CTP for the central gray matter (GM) and the whole brain. Our results indicate that the method used for correction of partial volume effects (PVEs) improves MRP experiments by reducing AIF-introduced variance at 1.5T. PMID:19253361

  4. Absolute perfusion measurements and associated iodinated contrast agent time course in brain metastasis: a study for contrast-enhanced radiotherapy

    PubMed Central

    Obeid, Layal; Deman, Pierre; Tessier, Alexandre; Balosso, Jacques; Estève, François; Adam, Jean- François

    2014-01-01

    Contrast-enhanced radiotherapy is an innovative treatment that combines the selective accumulation of heavy elements in tumors with stereotactic irradiations using medium energy X-rays. The radiation dose enhancement depends on the absolute amount of iodine reached in the tumor and its time course. Quantitative, postinfusion iodine biodistribution and associated brain perfusion parameters were studied in human brain metastasis as key parameters for treatment feasibility and quality. Twelve patients received an intravenous bolus of iodinated contrast agent (CA) (40 mL, 4 mL/s), followed by a steady-state infusion (160 mL, 0.5 mL/s) to ensure stable intratumoral amounts of iodine during the treatment. Absolute iodine concentrations and quantitative perfusion maps were derived from 40 multislice dynamic computed tomography (CT) images of the brain. The postinfusion mean intratumoral iodine concentration (over 30 minutes) reached 1.94±0.12 mg/mL. Reasonable correlations were obtained between these concentrations and the permeability surface area product and the cerebral blood volume. To our knowledge, this is the first quantitative study of CA biodistribution versus time in brain metastasis. The study shows that suitable and stable amounts of iodine can be reached for contrast-enhanced radiotherapy. Moreover, the associated perfusion measurements provide useful information for the patient recruitment and management processes. PMID:24447951

  5. The preference of visualization in teaching and learning absolute value

    NASA Astrophysics Data System (ADS)

    Cihan Konyalioğlu, Alper; Aksu, Zeki; Özge Şenel, Esma

    2012-07-01

    Visualization is mostly despised although it complements and - sometimes - guides the analytical process. This study mainly investigates teachers' preferences concerning the use of the visualization method and determines the extent to which they encourage their students to make use of it within the problem-solving process. This study was conducted for the ninth-grade students and their mathematics teacher in a social science intensive public school in the city of Erzurum, Turkey. Utilizing case study as the preferred method, data were collected through observations, interviews and student evaluations. This study revealed that visualization has a positive effect at the preliminary phases of teaching the absolute value concept but generates a lack of stimulation during problem solving in further phases of the instruction. This could be explained as a result of current examination system which requires a habituation of the analytical process in solving mathematical questions.

  6. Precision absolute value amplifier for a precision voltmeter

    SciTech Connect

    Hearn, W. E.; Rondeau, D. J.

    1985-05-21

    Bipolar inputs are afforded by the plus inputs of first and second differential input amplifiers. A first gain determining resister is connected between the minus inputs of the differential amplifiers. First and second diodes are connected between the respective minus inputs and the respective outputs of the differential amplifiers. First and second FETs have their gates connected to the outputs of the amplifiers, while their respective source and drain circuits are connected between the respective minus inputs and an output lead extending to a load resister. The output current through the load resister is proportional to the absolute value of the input voltage difference between the bipolar input terminals. A third differential amplifier has its plus input terminal connected to the load resister. A second gain determining resister is connected between the minus input of the third differential amplifier and a voltage source. A third FET has its gate connected to the output of the third amplifier. The source and drain circuit of the third transistor is connected between the minus input of the third amplifier and a voltage-frequency converter, constituting an output device. A polarity detector is also provided, comprising a pair of transistors having their inputs connected to the outputs of the first and second differential amplifiers. The outputs of the polarity detector are connected to gates which switch the output of the voltage-frequency converter between up and down counting outputs.

  7. Precision absolute value amplifier for a precision voltmeter

    DOEpatents

    Hearn, William E.; Rondeau, Donald J.

    1985-01-01

    Bipolar inputs are afforded by the plus inputs of first and second differential input amplifiers. A first gain determining resister is connected between the minus inputs of the differential amplifiers. First and second diodes are connected between the respective minus inputs and the respective outputs of the differential amplifiers. First and second FETs have their gates connected to the outputs of the amplifiers, while their respective source and drain circuits are connected between the respective minus inputs and an output lead extending to a load resister. The output current through the load resister is proportional to the absolute value of the input voltage difference between the bipolar input terminals. A third differential amplifier has its plus input terminal connected to the load resister. A second gain determining resister is connected between the minus input of the third differential amplifier and a voltage source. A third FET has its gate connected to the output of the third amplifier. The source and drain circuit of the third transistor is connected between the minus input of the third amplifier and a voltage-frequency converter, constituting an output device. A polarity detector is also provided, comprising a pair of transistors having their inputs connected to the outputs of the first and second differential amplifiers. The outputs of the polarity detector are connected to gates which switch the output of the voltage-frequency converter between up and down counting outputs.

  8. Precision absolute-value amplifier for a precision voltmeter

    DOEpatents

    Hearn, W.E.; Rondeau, D.J.

    1982-10-19

    Bipolar inputs are afforded by the plus inputs of first and second differential input amplifiers. A first gain determining resistor is connected between the minus inputs of the differential amplifiers. First and second diodes are connected between the respective minus inputs and the respective outputs of the differential amplifiers. First and second FETs have their gates connected to the outputs of the amplifiers, while their respective source and drain circuits are connected between the respective minus inputs and an output lead extending to a load resistor. The output current through the load resistor is proportional to the absolute value of the input voltage difference between the bipolar input terminals. A third differential amplifier has its plus input terminal connected to the load resistor. A second gain determining resistor is connected between the minus input of the third differential amplifier and a voltage source. A third FET has its gate connected to the output of the third amplifier. The source and drain circuit of the third transistor is connected between the minus input of the third amplifier and a voltage-frequency converter, constituting an output device. A polarity detector is also provided, comprising a pair of transistors having their inputs connected to the outputs of the first and second differential amplifiers. The outputs of the polarity detector are connected to gates which switch the output of the voltage-frequency converter between up and down counting outputs.

  9. A Special Application of Absolute Value Techniques in Authentic Problem Solving

    ERIC Educational Resources Information Center

    Stupel, Moshe

    2013-01-01

    There are at least five different equivalent definitions of the absolute value concept. In instances where the task is an equation or inequality with only one or two absolute value expressions, it is a worthy educational experience for learners to solve the task using each one of the definitions. On the other hand, if more than two absolute value…

  10. The Cauchy principal value and the Hadamard finite part integral as values of absolutely convergent integrals

    NASA Astrophysics Data System (ADS)

    Galapon, Eric A.

    2016-03-01

    The divergent integral ∫a b f ( x ) ( x - x 0 ) - n - 1 d x , for -∞ < a < x0 < b < ∞ and n = 0, 1, 2, …, is assigned, under certain conditions, the value equal to the simple average of the contour integrals ∫C±f(z)(z - x0)-n-1dz, where C+ (C-) is a path that starts from a and ends at b and which passes above (below) the pole at x0. It is shown that this value, which we refer to as the analytic principal value, is equal to the Cauchy principal value for n = 0 and to the Hadamard finite-part of the divergent integral for positive integer n. This implies that, where the conditions apply, the Cauchy principal value and the Hadamard finite-part integral are in fact values of absolutely convergent integrals. Moreover, it leads to the replacement of the boundary values in the Sokhotski-Plemelj-Fox theorem with integrals along some arbitrary paths. The utility of the analytic principal value in the numerical, analytical, and asymptotic evaluations of the principal value and the finite-part integral is discussed and demonstrated.

  11. CT-perfusion imaging of the human brain: advanced deconvolution analysis using circulant singular value decomposition.

    PubMed

    Wittsack, H J; Wohlschläger, A M; Ritzl, E K; Kleiser, R; Cohnen, M; Seitz, R J; Mödder, U

    2008-01-01

    According to indicator dilution theory tissue time-concentration curves have to be deconvolved with arterial input curves in order to get valid perfusion results. Our aim was to adapt and validate a deconvolution method originating from magnetic resonance techniques and apply it to the calculation of dynamic contrast enhanced computed tomography perfusion imaging. The application of a block-circulant matrix approach for singular value decomposition renders the analysis independent of tracer arrival time to improve the results. PMID:18029143

  12. Absolute value equations - what can we learn from their graphical representation?

    NASA Astrophysics Data System (ADS)

    Stupel, Moshe; Ben-Chaim, David

    2014-08-01

    Understanding graphical representations of algebraic equations, particularly graphical representations of absolute value equations, significantly improves students' mathematical comprehension and ignites within them an appreciation of the beauty and aesthetics of mathematics. In this paper, we focus on absolute value equations of linear and quadratic expressions, by examining various cases, presenting different methods of solving them by graphical representation, exhibiting the advantage of using dynamic software such as GeoGebra in solving them, and illustrating some examples of interesting graphical solutions. We recommend that teachers take advantage of the rapid development in technology to help learners tangibly visualize the solutions of absolute value equations before proceeding to the analytical solutions.

  13. Phase-based metamorphosis of diffusion lesion in relation to perfusion values in acute ischemic stroke.

    PubMed

    Rekik, Islem; Allassonnière, Stéphanie; Luby, Marie; Carpenter, Trevor K; Wardlaw, Joanna M

    2015-01-01

    Examining the dynamics of stroke ischemia is limited by the standard use of 2D-volume or voxel-based analysis techniques. Recently developed spatiotemporal models such as the 4D metamorphosis model showed promise for capturing ischemia dynamics. We used a 4D metamorphosis model to evaluate acute ischemic stroke lesion morphology from the acute diffusion-weighted imaging (DWI) to final T2-weighted imaging (T2-w). In 20 representative patients, we metamorphosed the acute lesion to subacute lesion to final infarct. From the DWI lesion deformation maps we identified dynamic lesion areas and examined their association with perfusion values inside and around the lesion edges, blinded to reperfusion status. We then tested the model in ten independent patients from the STroke Imaging Repository (STIR). Perfusion values varied widely between and within patients, and were similar in contracting and expanding DWI areas in many patients in both datasets. In 25% of patients, the perfusion values were higher in DWI-contracting than DWI-expanding areas. A similar wide range of perfusion values and ongoing expansion and contraction of the DWI lesion were seen subacutely. There was more DWI contraction and less expansion in patients who received thrombolysis, although with widely ranging perfusion values that did not differ. 4D metamorphosis modeling shows promise as a method to improve use of multimodal imaging to understand the evolution of acute ischemic tissue towards its fate. PMID:26288755

  14. Relation between regional myocardial uptake of /sup 82/Rb and perfusion: absolute reduction of cation uptake in ischemia

    SciTech Connect

    Selwyn, A.P.; Allan, R.M.; L'Abbate, A.; Horlock, P.; Camici, P.; Clark, J.; O'Brien, H.A.; Grant, P.M.

    1982-07-01

    Experiments were undertaken using /sup 82/Rb and position tomography to examine the relation between myocardial perfusion and cation uptake during acute ischemia. /sup 82/Rb was repeatedly eluted from a /sup 82/Sr-/sup 82/Rb generator. In six dogs emission tomograms were used to measure the delivered arterial and myocardial concentrations at rest and after coronary stenosis, stress and ischemia. There was a poor overall relation between regional myocardial uptake and flow measured by microspheres and a large individual variability. Extraction of /sup 82/Rb was inversely related to flow. Significant regional reduction of cation uptake was detected in the tomograms when regional flow decreased by more than 35 percent. This reduction was significantly greater when ischemia was present. A small but significantly greater when ischemia was present. A small but significant decrease (33.0 +/- 9.1 percent, mean +/- standard deviation) in the myocardial uptake of /sup 82/Rb was detected only when flow was increased by more than 120 percent in relation to a control area after administration of dypiridamole. The technique using /sup 82/Rb and tomography was applied in five volunteers and five patients with angina pectoris and coronary artery disease. Myocardial tomograms recorded at rest and after exercise in the volunteers showed homogeneous uptake of cation in reproducible and repeatable scans. In contrast, the patients with coronary artery disease showed an absolute mean decrease of 36 +/- 14 percent in regional myocardial uptake of /sup 82/Rb after exercise. These abnormalities persisted in serial tomograms for more than 20 minutes after the symptoms and electrocardiographic signs of ischemia.

  15. Value of Dynamic Susceptibility Contrast Perfusion MRI in the Acute Phase of Transient Global Amnesia

    PubMed Central

    Förster, Alex; Al-Zghloul, Mansour; Kerl, Hans U.; Böhme, Johannes; Mürle, Bettina; Groden, Christoph

    2015-01-01

    Purpose Transient global amnesia (TGA) is a transitory, short-lasting neurological disorder characterized by a sudden onset of antero- and retrograde amnesia. Perfusion abnormalities in TGA have been evaluated mainly by use of positron emission tomography (PET) or single-photon emission computed tomography (SPECT). In the present study we explore the value of dynamic susceptibility contrast perfusion-weighted MRI (PWI) in TGA in the acute phase. Methods From a MRI report database we identified TGA patients who underwent MRI including PWI in the acute phase and compared these to control subjects. Quantitative perfusion maps (cerebral blood flow (CBF) and volume (CBV)) were generated and analyzed by use of Signal Processing In NMR-Software (SPIN). CBF and CBV values in subcortical brain regions were assessed by use of VOI created in FIRST, a model-based segmentation tool in the Oxford Centre for Functional Magnetic Resonance Imaging of the Brain (FMRIB) Software Library (FSL). Results Five TGA patients were included (2 men, 3 women). On PWI, no relevant perfusion alterations were found by visual inspection in TGA patients. Group comparisons for possible differences between TGA patients and control subjects showed significant lower rCBF values bilaterally in the hippocampus, in the left thalamus and globus pallidus as well as bilaterally in the putamen and the left caudate nucleus. Correspondingly, significant lower rCBV values were observed bilaterally in the hippocampus and the putamen as well as in the left caudate nucleus. Group comparisons for possible side differences in rCBF and rCBV values in TGA patients revealed a significant lower rCBV value in the left caudate nucleus. Conclusions Mere visual inspection of PWI is not sufficient for the assessment of perfusion changes in TGA in the acute phase. Group comparisons with healthy control subjects might be useful to detect subtle perfusion changes on PWI in TGA patients. However, this should be confirmed in

  16. A special application of absolute value techniques in authentic problem solving

    NASA Astrophysics Data System (ADS)

    Stupel, Moshe

    2013-06-01

    There are at least five different equivalent definitions of the absolute value concept. In instances where the task is an equation or inequality with only one or two absolute value expressions, it is a worthy educational experience for learners to solve the task using each one of the definitions. On the other hand, if more than two absolute value expressions are involved, the definition that is most helpful is the one involving solving by intervals and evaluating critical points. In point of fact, application of this technique is one reason that the topic of absolute value is important in mathematics in general and in mathematics teaching in particular. We present here an authentic practical problem that is solved using absolute values and the 'intervals' method, after which the solution is generalized with surprising results. This authentic problem also lends itself to investigation using educational technological tools such as GeoGebra dynamic geometry software: mathematics teachers can allow their students to initially cope with the problem by working in an inductive environment in which they conduct virtual experiments until a solid conjecture has been reached, after which they should prove the conjecture deductively, using classic theoretical mathematical tools.

  17. Maple (Computer Algebra System) in Teaching Pre-Calculus: Example of Absolute Value Function

    ERIC Educational Resources Information Center

    Tuluk, Güler

    2014-01-01

    Modules in Computer Algebra Systems (CAS) make Mathematics interesting and easy to understand. The present study focused on the implementation of the algebraic, tabular (numerical), and graphical approaches used for the construction of the concept of absolute value function in teaching mathematical content knowledge along with Maple 9. The study…

  18. A Multidimensional Approach to Explore the Understanding of the Notion of Absolute Value

    ERIC Educational Resources Information Center

    Gagatsis, Athanasios; Panaoura, Areti

    2014-01-01

    The study aimed to investigate students' conceptions on the notion of absolute value and their abilities in applying the specific notion in routine and non-routine situations. A questionnaire was constructed and administered to 17-year-old students. Data were analysed using the hierarchical clustering of variables and the implicative method,…

  19. Segmental analysis of thallium 201 myocardial perfusion scintigraphy: its value in a community hospital.

    PubMed

    Tendera, M; Campbell, W B; Moyers, J R

    1984-08-01

    In a community hospital, we correlated results of thallium 201 myocardial scintigraphy with coronary arteriographic data in 79 patients. Scintigraphy was 92% sensitive and 85% specific in detecting coronary artery disease. There were no false-negative scintigrams in patients with double or triple vessel disease. The most important factors determining sensitivity of the method in detecting individual coronary stenoses were (1) location of the stenosis in the coronary tree, (2) number of vessels involved, and (3) degree of obstruction. Higher prevalence of perfusion defects in areas of 90% to 99% stenosis as compared with 50% to 89% lesions was of borderline statistical significance (86% vs 59%; P = .06). Myocardial perfusion scintigraphy was unable to predict the number of significantly narrowed coronary vessels. Predictive value of a perfusion defect for a significant coronary stenosis was 87% for anterior, 88% for septal, 90% for lateral, 89% for posterior, and 78% for inferior segment. We conclude that segmental analysis of myocardial scintigrams may be of value in a community hospital. PMID:6463700

  20. Multiphase permittivity imaging using absolute value electrical capacitance tomography data and a level set algorithm.

    PubMed

    Al Hosani, E; Soleimani, M

    2016-06-28

    Multiphase flow imaging is a very challenging and critical topic in industrial process tomography. In this article, simulation and experimental results of reconstructing the permittivity profile of multiphase material from data collected in electrical capacitance tomography (ECT) are presented. A multiphase narrowband level set algorithm is developed to reconstruct the interfaces between three- or four-phase permittivity values. The level set algorithm is capable of imaging multiphase permittivity by using one set of ECT measurement data, so-called absolute value ECT reconstruction, and this is tested with high-contrast and low-contrast multiphase data. Simulation and experimental results showed the superiority of this algorithm over classical pixel-based image reconstruction methods. The multiphase level set algorithm and absolute ECT reconstruction are presented for the first time, to the best of our knowledge, in this paper and critically evaluated. This article is part of the themed issue 'Supersensing through industrial process tomography'. PMID:27185966

  1. Absolute value optimization to estimate phase properties of stochastic time series

    NASA Technical Reports Server (NTRS)

    Scargle, J. D.

    1977-01-01

    Most existing deconvolution techniques are incapable of determining phase properties of wavelets from time series data; to assure a unique solution, minimum phase is usually assumed. It is demonstrated, for moving average processes of order one, that deconvolution filtering using the absolute value norm provides an estimate of the wavelet shape that has the correct phase character when the random driving process is nonnormal. Numerical tests show that this result probably applies to more general processes.

  2. The Impact of Different Absolute Solar Irradiance Values on Current Climate Model Simulations

    NASA Technical Reports Server (NTRS)

    Rind, David H.; Lean, Judith L.; Jonas, Jeffrey

    2014-01-01

    Simulations of the preindustrial and doubled CO2 climates are made with the GISS Global Climate Middle Atmosphere Model 3 using two different estimates of the absolute solar irradiance value: a higher value measured by solar radiometers in the 1990s and a lower value measured recently by the Solar Radiation and Climate Experiment. Each of the model simulations is adjusted to achieve global energy balance; without this adjustment the difference in irradiance produces a global temperature change of 0.48C, comparable to the cooling estimated for the Maunder Minimum. The results indicate that by altering cloud cover the model properly compensates for the different absolute solar irradiance values on a global level when simulating both preindustrial and doubled CO2 climates. On a regional level, the preindustrial climate simulations and the patterns of change with doubled CO2 concentrations are again remarkably similar, but there are some differences. Using a higher absolute solar irradiance value and the requisite cloud cover affects the model's depictions of high-latitude surface air temperature, sea level pressure, and stratospheric ozone, as well as tropical precipitation. In the climate change experiments it leads to an underestimation of North Atlantic warming, reduced precipitation in the tropical western Pacific, and smaller total ozone growth at high northern latitudes. Although significant, these differences are typically modest compared with the magnitude of the regional changes expected for doubled greenhouse gas concentrations. Nevertheless, the model simulations demonstrate that achieving the highest possible fidelity when simulating regional climate change requires that climate models use as input the most accurate (lower) solar irradiance value.

  3. CT Perfusion in the Characterisation of Renal Lesions: An Added Value to Multiphasic CT

    PubMed Central

    Pozzessere, Chiara; D'Elia, Domenico; Ambrosio, Maria Raffaella; Barone, Aurora; del Vecchio, Maria Teresa

    2014-01-01

    Objective. To prospectively evaluate if computed tomography perfusion (CTp) could be a useful tool in addition to multiphasic CT in renal lesion characterisation. Materials and Methods. Fifty-eight patients that were scheduled for surgical resection of a renal mass with a suspicion of renal cell carcinoma (RCC) were enrolled. Forty-one out of 58 patients underwent total or partial nephrectomy after CTp examination, and a pathological analysis was obtained for a total of 49 renal lesions. Perfusion parameters and attenuation values at multiphasic CT for both lesion and normal cortex were analysed. All the results were compared with the histological data obtained following surgery. Results. PS and MTT values were significantly lower in malignant lesions than in the normal cortex (P < 0.001 and P = 0.011, resp.); PS, MTT, and BF values were also statistically different between oncocytomas and malignant lesions. According to ROC analysis, the accuracy, sensitivity, and specificity to predict RCC were 95.92%, 100%, and 66.7%, respectively, for CTp whereas they were 89.80%, 93.35%, and 50%, respectively, for multiphasic CT. Conclusion. A significant difference between renal cortex and tumour CTp parameter values may suggest a malignant renal lesion. CTp could represent an added value to multiphasic CT in differentiating renal cells carcinoma from oncocytoma. PMID:25184133

  4. Quantification of absolute myocardial perfusion at rest and during exercise with positron emission tomography after human cardiac transplantation.

    PubMed

    Krivokapich, J; Stevenson, L W; Kobashigawa, J; Huang, S C; Schelbert, H R

    1991-08-01

    The maximal exercise capacity of cardiac transplant recipients is reduced compared with that of normal subjects. To determine if this reduced exercise capacity is related to inadequate myocardial perfusion during exercise, myocardial perfusion was measured noninvasively with use of positron emission tomography and nitrogen (N)-13 ammonia. Twelve transplant recipients with no angiographic evidence of accelerated coronary atherosclerosis were studied. Serial N-13 ammonia imaging was performed at rest and during supine bicycle exercise. The results were compared with those from 10 normal volunteers with a low probability of having cardiac disease. A two-compartment kinetic model for estimating myocardial perfusion was applied to the data. Transplant recipients achieved a significant lower exercise work load than did the volunteers (42 +/- 16 vs. 128 +/- 22 W), but a higher venous lactate concentration (31.3 +/- 14.9 vs. 13.7 +/- 4.1 mg/100 ml). Despite the difference in exercise work load, there was no significant difference in the cardiac work achieved by transplant recipients and normal subjects as evidenced by similar rate-pressure products of 24,000 +/- 3,400 versus 21,300 +/- 2,800 betas/min per mm Hg, respectively. In addition, myocardial blood flow during exercise was not significantly different between the two groups (1.70 +/- 0.60 vs. 1.56 +/- 0.71 ml/min per g, respectively). This study demonstrates that the myocardial flow response to the physiologic stress of exercise is appropriate in transplant recipients and does not appear to explain the decreased exercise capacity in these patients. PMID:1856420

  5. Quantification of absolute myocardial perfusion at rest and during exercise with positron emission tomography after human cardiac transplantation

    SciTech Connect

    Krivokapich, J.; Stevenson, L.W.; Kobashigawa, J.; Huang, S.C.; Schelbert, H.R. )

    1991-08-01

    The maximal exercise capacity of cardiac transplant recipients is reduced compared with that of normal subjects. To determine if this reduced exercise capacity is related to inadequate myocardial perfusion during exercise, myocardial perfusion was measured noninvasively with use of positron emission tomography and nitrogen (N)-13 ammonia. Twelve transplant recipients with no angiographic evidence of accelerated coronary atherosclerosis were studied. Serial N-13 ammonia imaging was performed at rest and during supine bicycle exercise. The results were compared with those from 10 normal volunteers with a low probability of having cardiac disease. A two-compartment kinetic model for estimating myocardial perfusion was applied to the data. Transplant recipients achieved a significant lower exercise work load than did the volunteers (42 {plus minus} 16 vs. 128 {plus minus} 22 W), but a higher venous lactate concentration (31.3 {plus minus} 14.9 vs. 13.7 {plus minus} 4.1 mg/100 ml). Despite the difference in exercise work load, there was no significant difference in the cardiac work achieved by transplant recipients and normal subjects as evidenced by similar rate-pressure products of 24,000 {plus minus} 3,400 versus 21,300 {plus minus} 2,800 betas/min per mm Hg, respectively. In addition, myocardial blood flow during exercise was not significantly different between the two groups (1.70 {plus minus} 0.60 vs. 1.56 {plus minus} 0.71 ml/min per g, respectively). This study demonstrates that the myocardial flow response to the physiologic stress of exercise is appropriate in transplant recipients and does not appear to explain the decreased exercise capacity in these patients.

  6. Cardiac magnetic resonance imaging for myocardial perfusion and diastolic function—reference control values for women

    PubMed Central

    Bakir, May; Wei, Janet; Nelson, Michael D.; Mehta, Puja K.; Haftbaradaran, Afsaneh; Jones, Erika; Gill, Edward; Sharif, Behzad; Slomka, Piotr J.; Li, Debiao; Shufelt, Chrisandra L.; Minissian, Margo; Berman, Daniel S.; Bairey Merz, C. Noel

    2016-01-01

    Angina, heart failure with preserved ejection fraction (HFpEF) and coronary microvascular dysfunction (CMD) in the absence of obstructive coronary artery disease (CAD) are more common in women and are associated with adverse cardiovascular prognosis. Cardiac magnetic resonance imaging (CMRI) is established for assessment of left ventricular (LV) morphology and systolic function and is increasingly used to assess myocardial perfusion and diastolic function. Indeed, stress CMRI allows measurement of myocardial perfusion reserve index (MPRI) using semi-quantitative techniques, and quantification of LV volumetric filling patterns provides valuable insight into LV diastolic function. The utility of these two techniques remains limited, because reference control values for MPRI and LV diastolic function in asymptomatic middle-aged, women have not previously been established. To address this limitation, we recruited twenty women, without clinical cardiovascular disease or cardiovascular risk factors, with normal maximal Bruce protocol exercise treadmill testing. Subjects underwent CMRI (1.5 tesla) using a standardized protocol of adenosine stress and rest perfusion and LV cinematic imaging. Commercially available with automated CMRI segmentation was used for calculation of MPRI, LV filling profiles, and ejection fraction. Mean age was 54±9 years and mean body mass index was 25±4 kg/m3. The exercise treadmill testing results demonstrated a normotensive group with normal functional capacity and hemodynamic response. We report reference control values for semi-quantitative MPRI as well as measures of LV systolic and diastolic function including ejection fraction, stroke volume, peak filling rate (PFR), PFR adjusted for end-diastolic volume (EDV) and stroke volume, time to PFR, and EDV index. The data herein provide reference values for MPRI and diastolic function in a cohort of healthy, middle-aged of women. These reference values may be used for comparison with a variety

  7. A redetermination of absolute values for 17RVPDB-CO2 and 17RVSMOW.

    PubMed

    Assonov, Sergey S; Brenninkmeijer, Carl A M

    2003-01-01

    In a companion paper in this issue we presented a review of the current state of (17)O-corrections for CO(2) mass spectrometry and considered an approach (including algebraic formulae) of how to determine absolute values for (17)R(VPDB-CO2) and (17)R(VSMOW). Here we present the results of experiments conducted to determine these values. Two oxygen gases (one depleted in heavy isotopes and the other isotopically normal oxygen) were analysed to obtain the relative (17)O content. Samples of both gases were converted into CO(2), and the resulting CO(2) samples were analysed as well. Possible experimental and analytical errors are carefully considered and eliminated as far as feasible. Much attention was paid to understanding and dealing with cross-contamination effects occurring in the mass spectrometer. Based on the data obtained, the absolute values are calculated to be: (17)R(VPDB-CO2) = 0.00039511 +/- 0.00000094 and (17)R(VSMOW) = 0.00038672 +/- 0.00000087 (expanded uncertainties). Both values are on the original scale of Craig (Geochim. Cosmochim. Acta 1957; 12: 133-149) with (13)R(VPDB-CO2) = 0.0112372. A (17)O-correction algorithm incorporating the newly determined value for (17)R(VPDB-CO2) and lambda = 0.528 by Meijer and Li (Isot. Environ. Health Stud. 1998; 34: 349-369) is constructed. A computational test is performed to demonstrate the degree of delta(13)C bias relative to the previously known correction algorithms. delta(13)C values produced by the constructed algorithm are in the middle of the values produced by the other algorithms. We refrain, however, from giving any recommendation concerning which (17)O-correction algorithm to use in order to obtain delta(13)C data in the most accurate way. The present work illuminates the need to reconsider recommendations concerning the correction algorithm. PMID:12720281

  8. Accuracy, Precision, Sensitivity, and Specificity of Noninvasive ICP Absolute Value Measurements.

    PubMed

    Krakauskaite, Solventa; Petkus, Vytautas; Bartusis, Laimonas; Zakelis, Rolandas; Chomskis, Romanas; Preiksaitis, Aidanas; Ragauskas, Arminas; Matijosaitis, Vaidas; Petrikonis, Kestutis; Rastenyte, Daiva

    2016-01-01

    An innovative absolute intracranial pressure (ICP) value measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler (TCD) technology and uses intracranial and extracranial segments of the ophthalmic artery as pressure sensors. The ophthalmic artery is used as a natural pair of "scales" that compares ICP with controlled pressure Pe, which is externally applied to the orbit. To balance the scales, ICP = Pe a special two-depth TCD device was used as a pressure balance indicator. The proposed method is the only noninvasive ICP measurement method that does not need patient-specific calibration. PMID:27165929

  9. Theoretical prediction of relative and absolute pKa values of aminopyridines.

    PubMed

    Caballero, N A; Melendez, F J; Muñoz-Caro, C; Niño, A

    2006-11-20

    This work presents a study aimed at the theoretical prediction of pK(a) values of aminopyridines, as a factor responsible for the activity of these compounds as blockers of the voltage-dependent K(+) channels. To cover a large range of pK(a) values, a total of seven substituted pyridines is considered as a calibration set: pyridine, 2-aminopyridine, 3-aminopyridine, 4-aminopyridine, 2-chloropyridine, 3-chloropyridine, and 4-methylpirydine. Using ab initio G1, G2 and G3 extrapolation methods, and the CPCM variant of the Polarizable Continuum Model for solvation, we calculate gas phase and solvation free energies. pK(a) values are obtained from these data using a thermodynamic cycle for describing protonation in aqueous and gas phases. The results show that the relatively inexpensive G1 level of theory is the most accurate at predicting pK(a) values in aminopyridines. The highest standard deviation with respect to the experimental data is 0.69 pK(a) units for absolute values calculations. The difference increases slightly to 0.74 pK(a) units when the pK(a) is computed relative to the pyridine molecule. Considering only compounds at least as basic as pyridine (the values of interest for bioactive aminopyridines) the error falls to 0.10 and 0.12 pK(a) units for the absolute and relative computations, respectively. The technique can be used to predict the effect of electronegative substituents in the pK(a) of 4-AP, the most active aminopyridine considered in this work. Thus, 2-chloro and 3-chloro-4-aminopyridine are taken into account. The results show a decrease of the pK(a), suggesting that these compounds are less active than 4-AP at blocking the K(+) channel. PMID:16844281

  10. Cerebral perfusion and oxygenation are impaired by folate deficiency in rat: absolute measurements with noninvasive near-infrared spectroscopy

    PubMed Central

    Hallacoglu, Bertan; Sassaroli, Angelo; Fantini, Sergio; Troen, Aron M

    2011-01-01

    Brain microvascular pathology is a common finding in Alzheimer's disease and other dementias. However, the extent to which microvascular abnormalities cause or contribute to cognitive impairment is unclear. Noninvasive near-infrared spectroscopy (NIRS) can address this question, but its use for clarifying the role of microvascular dysfunction in dementia has been limited due to theoretical and practical considerations. We developed a new noninvasive NIRS method to obtain quantitative, dynamic measurements of absolute brain hemoglobin concentration and oxygen saturation and used it to show significant cerebrovascular impairments in a rat model of diet-induced vascular cognitive impairment. We fed young rats folate-deficient (FD) and control diets and measured absolute brain hemoglobin and hemodynamic parameters at rest and during transient mild hypoxia and hypercapnia. With respect to control animals, FD rats featured significantly lower brain hemoglobin concentration (72±4 μmol/L versus 95±6 μmol/L) and oxygen saturation (54%±3% versus 65%±2%). By contrast, resting arterial oxygen saturation was the same for both groups (96%±4%), indicating that decrements in brain hemoglobin oxygenation were independent of blood oxygen carrying capacity. Vasomotor reactivity in response to hypercapnia was also impaired in FD rats. Our results implicate microvascular abnormality and diminished oxygen delivery as a mechanism of cognitive impairment. PMID:21386853

  11. Prognostic value of combined visualization of MR diffusion and perfusion maps in glioblastoma.

    PubMed

    Deike, Katerina; Wiestler, Benedikt; Graf, Markus; Reimer, Caroline; Floca, Ralf O; Bäumer, Philipp; Kickingereder, Philipp; Heiland, Sabine; Schlemmer, Heinz-Peter; Wick, Wolfgang; Bendszus, Martin; Radbruch, Alexander

    2016-02-01

    We analyzed whether the combined visualization of decreased apparent diffusion coefficient (ADC) values and increased cerebral blood volume (CBV) in perfusion imaging can identify prognosis-related growth patterns in patients with newly diagnosed glioblastoma. Sixty-five consecutive patients were examined with diffusion and dynamic susceptibility-weighted contrast-enhanced perfusion weighted MRI. ADC and CBV maps were co-registered on the T1-w image and a region of interest (ROI) was manually delineated encompassing the enhancing lesion. Within this ROI pixels with ADC values values >the 70th percentile (CBVmax) and the intersection of pixels with ADCmin and CBVmax were automatically calculated and visualized. Initially, all tumors with a mean intersection greater than the upper quartile of the normally distributed mean intersection of all patients were subsumed to the first growth pattern termed big intersection (BI). Subsequently, the remaining tumors' growth patterns were categorized depending on the qualitative representation of ADCmin, CBVmax and their intersection. Log-rank test exposed a significantly longer overall survival of BI (n = 16) compared to non-BI group (n = 49) (p = 0.0057). Thirty-one, four and 14 patients of the non-BI group were classified as predominant ADC-, CBV- and mixed growth group, respectively. In a multivariate Cox regression model, the BI-, CBV- and mixed groups had significantly lower adjusted hazard ratios (p-value, α(Bonferroni) < 0.006) when compared to the reference group ADC: 0.29 (0.0027), 0.11 (0.038) and 0.33 (0.0059). Our study provides evidence that the combination of diffusion and perfusion imaging allows visualization of different glioblastoma growth patterns that are associated with prognosis. A possible biological hypothesis for this finding could be the interpretation of the ADCmin fraction as the invasion-front of tumor cells while the CBVmax fraction might represent

  12. Prospective Teachers' Reactions to "Right-or-Wrong" Tasks: The Case of Derivatives of Absolute Value Functions

    ERIC Educational Resources Information Center

    Tsamir, Pessia; Rasslan, Shaker; Dreyfus, Tommy

    2006-01-01

    This paper illustrates the role of a "Thinking-about-Derivatives" task in identifying learners' derivative conceptions and for promoting their critical thinking about derivatives of absolute value functions. The task included three parts: "Define" the derivative of a function f(x) at x = x[subscript 0], "Solve-if-Possible" the derivative of f(x) =…

  13. Delta Procalcitonin Is a Better Indicator of Infection Than Absolute Procalcitonin Values in Critically Ill Patients: A Prospective Observational Study.

    PubMed

    Trásy, Domonkos; Tánczos, Krisztián; Németh, Márton; Hankovszky, Péter; Lovas, András; Mikor, András; Hajdú, Edit; Osztroluczki, Angelika; Fazakas, János; Molnár, Zsolt

    2016-01-01

    Purpose. To investigate whether absolute value of procalcitonin (PCT) or the change (delta-PCT) is better indicator of infection in intensive care patients. Materials and Methods. Post hoc analysis of a prospective observational study. Patients with suspected new-onset infection were included in whom PCT, C-reactive protein (CRP), temperature, and leukocyte (WBC) values were measured on inclusion (t 0) and data were also available from the previous day (t -1). Based on clinical and microbiological data, patients were grouped post hoc into infection- (I-) and noninfection- (NI-) groups. Results. Of the 114 patients, 85 (75%) had proven infection. PCT levels were similar at t -1: I-group (median [interquartile range]): 1.04 [0.40-3.57] versus NI-group: 0.53 [0.16-1.68], p = 0.444. By t 0 PCT levels were significantly higher in the I-group: 4.62 [1.91-12.62] versus 1.12 [0.30-1.66], p = 0.018. The area under the curve to predict infection for absolute values of PCT was 0.64 [95% CI = 0.52-0.76], p = 0.022; for percentage change: 0.77 [0.66-0.87], p < 0.001; and for delta-PCT: 0.85 [0.78-0.92], p < 0.001. The optimal cut-off value for delta-PCT to indicate infection was 0.76 ng/mL (sensitivity 80 [70-88]%, specificity 86 [68-96]%). Neither absolute values nor changes in CRP, temperature, or WBC could predict infection. Conclusions. Our results suggest that delta-PCT values are superior to absolute values in indicating infection in intensive care patients. This trial is registered with ClinicalTrials.gov identifier: NCT02311816. PMID:27597981

  14. Delta Procalcitonin Is a Better Indicator of Infection Than Absolute Procalcitonin Values in Critically Ill Patients: A Prospective Observational Study

    PubMed Central

    Hankovszky, Péter; Hajdú, Edit

    2016-01-01

    Purpose. To investigate whether absolute value of procalcitonin (PCT) or the change (delta-PCT) is better indicator of infection in intensive care patients. Materials and Methods. Post hoc analysis of a prospective observational study. Patients with suspected new-onset infection were included in whom PCT, C-reactive protein (CRP), temperature, and leukocyte (WBC) values were measured on inclusion (t0) and data were also available from the previous day (t−1). Based on clinical and microbiological data, patients were grouped post hoc into infection- (I-) and noninfection- (NI-) groups. Results. Of the 114 patients, 85 (75%) had proven infection. PCT levels were similar at t−1: I-group (median [interquartile range]): 1.04 [0.40–3.57] versus NI-group: 0.53 [0.16–1.68], p = 0.444. By t0 PCT levels were significantly higher in the I-group: 4.62 [1.91–12.62] versus 1.12 [0.30–1.66], p = 0.018. The area under the curve to predict infection for absolute values of PCT was 0.64 [95% CI = 0.52–0.76], p = 0.022; for percentage change: 0.77 [0.66–0.87], p < 0.001; and for delta-PCT: 0.85 [0.78–0.92], p < 0.001. The optimal cut-off value for delta-PCT to indicate infection was 0.76 ng/mL (sensitivity 80 [70–88]%, specificity 86 [68-96]%). Neither absolute values nor changes in CRP, temperature, or WBC could predict infection. Conclusions. Our results suggest that delta-PCT values are superior to absolute values in indicating infection in intensive care patients. This trial is registered with ClinicalTrials.gov identifier: NCT02311816. PMID:27597981

  15. Prediction of postoperative pulmonary function following thoracic operations. Value of ventilation-perfusion scanning

    SciTech Connect

    Bria, W.F.; Kanarek, D.J.; Kazemi, H.

    1983-08-01

    Surgical resection of lung cancer is frequently required in patients with severely impaired lung function resulting from chronic obstructive pulmonary disease. Twenty patients with obstructive lung disease and cancer (mean preoperative forced expiratory volume in 1 second (FEV1) . 1.73 L) were studied preoperatively and postoperatively by spirometry and radionuclide perfusion, single-breath ventilation, and washout techniques to test the ability of these methods to predict preoperatively the partial loss of lung function by the resection. Postoperative FEV1 and forced vital capacity (FVC) were accurately predicted by the formula: postoperative FEV1 (or FVC) . preoperative FEV1 X percent function of regions of lung not to be resected (r . 0.88 and 0.95, respectively). Ventilation and perfusion scans are equally effective in prediction. Washout data add to the sophistication of the method by permitting the qualitative evaluation of ventilation during tidal breathing. Criteria for patients requiring the study are suggested.

  16. Calculation of absolute free energy of binding for theophylline and its analogs to RNA aptamer using nonequilibrium work values

    NASA Astrophysics Data System (ADS)

    Tanida, Yoshiaki; Ito, Masakatsu; Fujitani, Hideaki

    2007-08-01

    The massively parallel computation of absolute binding free energy with a well-equilibrated system (MP-CAFEE) has been developed [H. Fujitani, Y. Tanida, M. Ito, G. Jayachandran, C.D. Snow, M.R. Shirts, E.J. Sorin, V.S. Pande, J. Chem. Phys. 123 (2005) 084108]. As an application, we perform the binding affinity calculations of six theophylline-related ligands with RNA aptamer. Basically, our method is applicable when using many compute nodes to accelerate simulations, thus a parallel computing system is also developed. To further reduce the computational cost, the adequate non-uniform intervals of coupling constant λ, connecting two equilibrium states, namely bound and unbound, are determined. The absolute binding energies Δ G thus obtained have effective linear relation between the computed and experimental values. If the results of two other different methods are compared, thermodynamic integration (TI) and molecular mechanics Poisson-Boltzmann surface area (MM-PBSA) by the paper of Gouda et al. [H. Gouda, I.D. Kuntz, D.A. Case, P.A. Kollman, Biopolymers 68 (2003) 16], the predictive accuracy of the relative values ΔΔ G is almost comparable to that of TI: the correlation coefficients ( R) obtained are 0.99 (this work), 0.97 (TI), and 0.78 (MM-PBSA). On absolute binding energies meanwhile, a constant energy shift of ˜-7 kcal/mol against the experimental values is evident. To solve this problem, several presumable reasons are investigated.

  17. Differences between absolute and predicted values of forced expiratory volumes to classify ventilatory impairment in chronic obstructive pulmonary disease.

    PubMed

    Checkley, William; Foreman, Marilyn G; Bhatt, Surya P; Dransfield, Mark T; Han, MeiLan; Hanania, Nicola A; Hansel, Nadia N; Regan, Elizabeth A; Wise, Robert A

    2016-02-01

    The Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity criterion for COPD is used widely in clinical and research settings; however, it requires the use of ethnic- or population-specific reference equations. We propose two alternative severity criteria based on absolute post-bronchodilator FEV1 values (FEV1 and FEV1/height2) that do not depend on reference equations. We compared the accuracy of these classification schemasto those based on % predicted values (GOLD criterion) and Z-scores of post-bronchodilator FEV1 to predict COPD-related functional outcomes or percent emphysema by computerized tomography of the lung. We tested the predictive accuracy of all severity criteria for the 6-minute walk distance (6MWD), St. George's Respiratory Questionnaire (SGRQ), 36-item Short-Form Health Survey physical health component score (SF-36) and the MMRC Dyspnea Score. We used 10-fold cross-validation to estimate average prediction errors and Bonferroni-adjusted t-tests to compare average prediction errors across classification criteria. We analyzed data of 3772 participants with COPD (average age 63 years, 54% male). Severity criteria based on absolute post-bronchodilator FEV1 or FEV1/height2 yielded similar prediction errors for 6MWD, SGRQ, SF-36 physical health component score, and the MMRC Dyspnea Score when compared to the GOLD criterion (all p > 0.34); and, had similar predictive accuracy when compared with the Z-scores criterion, with the exception for 6MWD where post-bronchodilator FEV1 appeared to perform slightly better than Z-scores (p = 0.01). Subgroup analyses did not identify differences across severity criteria by race, sex, or age between absolute values and the GOLD criterion or one based on Z-scores. Severity criteria for COPD based on absolute values of post-bronchodilator FEV1 performed equally as well as did criteria based on predicted values when benchmarked against COPD-related functional and structural outcomes, are simple to use

  18. Advances in the Metrology of Absolute Value Assignments to Isotopic Reference Materials: Consequences from the Avogadro Project

    NASA Astrophysics Data System (ADS)

    Vocke, Robert; Rabb, Savelas

    2015-04-01

    All isotope amount ratios (hereafter referred to as isotope ratios) produced and measured on any mass spectrometer are biased. This unfortunate situation results mainly from the physical processes in the source area where ions are produced. Because the ionized atoms in poly-isotopic elements have different masses, such processes are typically mass dependent and lead to what is commonly referred to as mass fractionation (for thermal ionization and electron impact sources) and mass bias (for inductively coupled plasma sources.) This biasing process produces a measured isotope ratio that is either larger or smaller than the "true" ratio in the sample. This has led to the development of numerous fractionation "laws" that seek to correct for these effects, many of which are not based on the physical processes giving rise to the biases. The search for tighter and reproducible precisions has led to two isotope ratio measurement systems that exist side-by-side. One still seeks to measure "absolute" isotope ratios while the other utilizes an artifact based measurement system called a delta-scale. The common element between these two measurement systems is the utilization of isotope reference materials (iRMs). These iRMs are used to validate a fractionation "law" in the former case and function as a scale anchor in the latter. Many value assignments of iRMs are based on "best measurements" by the original groups producing the reference material, a not entirely satisfactory approach. Other iRMs, with absolute isotope ratio values, have been produced by calibrated measurements following the Atomic Weight approach (AW) pioneered by NBS nearly 50 years ago. Unfortunately, the AW is not capable of calibrating the new generation of iRMs to sufficient precision. So how do we get iRMs with isotope ratios of sufficient precision and without bias? Such a focus is not to denigrate the extremely precise delta-scale measurements presently being made on non-traditional and tradition

  19. Influence of Thin Slice Reconstruction on CT Brain Perfusion Analysis

    PubMed Central

    Bennink, Edwin; Oosterbroek, Jaap; Horsch, Alexander D.; Dankbaar, Jan Willem; Velthuis, Birgitta K.; Viergever, Max A.; de Jong, Hugo W. A. M.

    2015-01-01

    Objectives Although CT scanners generally allow dynamic acquisition of thin slices (1 mm), thick slice (≥5 mm) reconstruction is commonly used for stroke imaging to reduce data, processing time, and noise level. Thin slice CT perfusion (CTP) reconstruction may suffer less from partial volume effects, and thus yield more accurate quantitative results with increased resolution. Before thin slice protocols are to be introduced clinically, it needs to be ensured that this does not affect overall CTP constancy. We studied the influence of thin slice reconstruction on average perfusion values by comparing it with standard thick slice reconstruction. Materials and Methods From 50 patient studies, absolute and relative hemisphere averaged estimates of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and permeability-surface area product (PS) were analyzed using 0.8, 2.4, 4.8, and 9.6 mm slice reconstructions. Specifically, the influence of Gaussian and bilateral filtering, the arterial input function (AIF), and motion correction on the perfusion values was investigated. Results Bilateral filtering gave noise levels comparable to isotropic Gaussian filtering, with less partial volume effects. Absolute CBF, CBV and PS were 22%, 14% and 46% lower with 0.8 mm than with 4.8 mm slices. If the AIF and motion correction were based on thin slices prior to reconstruction of thicker slices, these differences reduced to 3%, 4% and 3%. The effect of slice thickness on relative values was very small. Conclusions This study shows that thin slice reconstruction for CTP with unaltered acquisition protocol gives relative perfusion values without clinically relevant bias. It does however affect absolute perfusion values, of which CBF and CBV are most sensitive. Partial volume effects in large arteries and veins lead to overestimation of these values. The effects of reconstruction slice thickness should be taken into account when absolute perfusion values are

  20. Differential diagnostic value of computed tomography perfusion combined with vascular endothelial growth factor expression in head and neck lesions

    PubMed Central

    WANG, JIE; TANG, ZUOHUA; WANG, SHUYI; ZENG, WENJIAO; QIAN, WEN; WU, LINGJIE; WANG, WENZHONG; LUO, JIANFENG

    2016-01-01

    There are numerous types of head and neck lesions (HNLs), and conventional computed tomography (CT) has low specificity and sensitivity in the definitive and differential diagnosis of HNLs. The aim of the present study was to evaluate the value of perfusion CT (CTP) combined with vascular endothelial growth factor (VEGF) expression in the differentiation between malignant and benign HNLs. In total, 41 HNLs, which were pathologically confirmed, underwent CTP and VEGF expression analysis. All lesions were divided into three groups: Group A, benign hypovascular lesions; Group B, benign hypervascular lesions; and Group C, malignant lesions. Time density curve (TDC) and CTP parameters [maximum intensity projection (MIP), blood volume (BV), blood flow (BF), mean transit time and capillary permeability] were analyzed. The association between perfusion measurements and VEGF was assessed using Pearson's correlation. TDCs were classified into three types, and type I was more frequently identified in benign tumors (Groups A and B) compared with malignant tumors (Group C) (P=0.003). Malignant tumors primarily had a TDC of type II and III. MIP, BF and BV were all significantly higher in Groups B and C compared to Group A (P<0.01). VEGF expression of malignant tumors was significantly higher than benign tumors (P=0.007). No correlation was identified between VEGF and any CTP parameter. The present findings suggest that CTP combined with VEGF may differentiate between malignant and benign HNLs, and between benign hypovascular and hypervascular lesions. PMID:27123114

  1. Estimation of brain perfusion using Va value as initial distribution volume in radionuclide angiography with technetium-99m HMPAO

    SciTech Connect

    Kawamoto, M.; Ikegami, T.

    1994-05-01

    Matsuda reported a non-invasive, simple method for the quantitative measurements of brain perfusion using radionuclide angiography with Tc-99m. HMPAO and showed graphical analysis of the ratio of brain activity to aortic arch activity gave two parameters, which are the slope of the fitted line (Ku:unidirectional influx constant) and its intercept with the yards (Vn:initial volume of distribution). Brain perfusion index (BPI),which is a connected Ku value, showed good correlation with cerebral blood flow determined with Xe-133 SPECT. The aim of our study is to elucidate the clinical significance of another parameter, Vn value, determined inpatients with cerebral vessel disease. Eighty-nine cases were studied and classified into three groups on the basis of clinical history and images of CT and/or MR: Group A, normal, 36 cases; Group B, infarction, 44 cases; Group C, subarachnoid hemorrhage, 9 cases. The average age of each group were not different statistically (63.3, 67.4 and 59.8, respectively). The average BPI values for group B and C were significantly lower than that of group A(7.7, 6. 8 and 9.5, respectively ). On the other hand, Vn for group C(0.23) was significantly lower than that for group A(0.45); however that for group B(0.49) was not. These findings indicate that cerebral blood flow in both infarction and subarachnoid hemorrhage decrease but their circumstances near vessels differ from the aspect of initial volume of tracer distribution. This might help to understand or diagnose cerebral vessel diseases.

  2. Comparison of methods for generation of absolute reflectance-factor values for bidirectional reflectance-distribution function studies.

    PubMed

    Feng, X; Schott, J R; Gallagher, T

    1993-03-01

    Currently, spectrophotometric standard reference materials are calibrated only by using the illumination and viewing geometries recommended by the Commission Internationale de l'Eclairage, and for some geometries the spectral range is limited to the visible wavelengths. A need exists for procedures that calibrate standards at many other geometries and for a broader spectral range. Two methods for calibrating the spectral bidirectional reflectance factor are described. The absolute bidirectional reflectance factor of a sintered polytetrafluoroethylene (PTFE) sample is determined for nearly all the possible illumination and viewing geometries from 400 nm to 2500 nm. The references are a 45/0 reflectance standard calibrated by the National Institute of Standards and Technology and a sintered PTFE sample with a directional, hemispherical reflectance factor traceable to the Institute. The results of the two methods agree to within 0.01 in reflectance factor values. With this PTFE sample as a transfer standard, the instrument described can also be used to measure the absolute bidirectional reflectance factor at nearly all the illumination and viewing geometries from 400 nm to 2500 nm. PMID:20820258

  3. Predicting Absolute Risk of Type 2 Diabetes Using Age and Waist Circumference Values in an Aboriginal Australian Community

    PubMed Central

    2015-01-01

    Objectives To predict in an Australian Aboriginal community, the 10-year absolute risk of type 2 diabetes associated with waist circumference and age on baseline examination. Method A sample of 803 diabetes-free adults (82.3% of the age-eligible population) from baseline data of participants collected from 1992 to 1998 were followed-up for up to 20 years till 2012. The Cox-proportional hazard model was used to estimate the effects of waist circumference and other risk factors, including age, smoking and alcohol consumption status, of males and females on prediction of type 2 diabetes, identified through subsequent hospitalisation data during the follow-up period. The Weibull regression model was used to calculate the absolute risk estimates of type 2 diabetes with waist circumference and age as predictors. Results Of 803 participants, 110 were recorded as having developed type 2 diabetes, in subsequent hospitalizations over a follow-up of 12633.4 person-years. Waist circumference was strongly associated with subsequent diagnosis of type 2 diabetes with P<0.0001 for both genders and remained statistically significant after adjusting for confounding factors. Hazard ratios of type 2 diabetes associated with 1 standard deviation increase in waist circumference were 1.7 (95%CI 1.3 to 2.2) for males and 2.1 (95%CI 1.7 to 2.6) for females. At 45 years of age with baseline waist circumference of 100 cm, a male had an absolute diabetic risk of 10.9%, while a female had a 14.3% risk of the disease. Conclusions The constructed model predicts the 10-year absolute diabetes risk in an Aboriginal Australian community. It is simple and easily understood and will help identify individuals at risk of diabetes in relation to waist circumference values. Our findings on the relationship between waist circumference and diabetes on gender will be useful for clinical consultation, public health education and establishing WC cut-off points for Aboriginal Australians. PMID:25876058

  4. Normal values for nuclear cardiology: Japanese databases for myocardial perfusion, fatty acid and sympathetic imaging and left ventricular function.

    PubMed

    Nakajima, Kenichi

    2010-04-01

    Myocardial normal databases for stress myocardial perfusion study have been created by the Japanese Society of Nuclear Medicine Working Group. The databases comprised gender-, camera rotation range- and radiopharmaceutical-specific data-sets from multiple institutions, and normal database files were created for installation in common nuclear cardiology software. Based on the electrocardiography-gated single-photon emission computed tomography (SPECT), left ventricular function, including ventricular volumes, systolic and diastolic functions and systolic wall thickening were also analyzed. Normal databases for fatty acid imaging using (123)I-beta-methyl-iodophenyl-pentadecanoic acid and sympathetic imaging using (123)I-meta-iodobenzylguanidine were also examined. This review provides lists and overviews of normal values for myocardial SPECT and ventricular function in a Japanese population. The population-specific approach is a key factor for proper diagnostic and prognostic evaluation. PMID:20108130

  5. Normal values for nuclear cardiology: Japanese databases for myocardial perfusion, fatty acid and sympathetic imaging and left ventricular function

    PubMed Central

    2010-01-01

    Myocardial normal databases for stress myocardial perfusion study have been created by the Japanese Society of Nuclear Medicine Working Group. The databases comprised gender-, camera rotation range- and radiopharmaceutical-specific data-sets from multiple institutions, and normal database files were created for installation in common nuclear cardiology software. Based on the electrocardiography-gated single-photon emission computed tomography (SPECT), left ventricular function, including ventricular volumes, systolic and diastolic functions and systolic wall thickening were also analyzed. Normal databases for fatty acid imaging using 123I-beta-methyl-iodophenyl-pentadecanoic acid and sympathetic imaging using 123I-meta-iodobenzylguanidine were also examined. This review provides lists and overviews of normal values for myocardial SPECT and ventricular function in a Japanese population. The population-specific approach is a key factor for proper diagnostic and prognostic evaluation. PMID:20108130

  6. Long-term variations of absolute and superconducting gravity values in Southeast Alaska, observed by the ISEA2 project

    NASA Astrophysics Data System (ADS)

    Kazama, T.; Hideaki, H.; Miura, S.; Kaufman, M.; Sato, T.; Larsen, C. F.; Freymueller, J. T.

    2013-12-01

    It is well known that gravity values have been decreasing in Southeast Alaska, mainly due to glacier mass changes from the end of the Little Ice Age to the present. For example, absolute gravity measurements made by the ISEA1 project (2006-2008) showed a maximum gravity change rate of -5.6 micro-gal/year (Sun et al., 2010; Sato et al., 2012a), which was consistent with large uplift rates obtained from GPS data (Larsen et al., 2005). However, the newly-obtained absolute gravity values in 2012 were about 10 micro-gal greater than expected based on the gravity trends of Sun et al. (2010), possibly because of above-average snowfall in the winter of 2011-2012 (Sato et al., 2012b). In order to monitor spatiotemporal gravity changes associated with glacier mass changes, seasonal hydrological gravity changes should be quantified via continuous gravity observations and/or hydrological modeling. We thus installed a superconducting gravimeter iGrav (serial number: 003) at Egan Library, University of Alaska Southeast in June 2012, as part of the ISEA2 project (2011-2015). The mass position (unit: volts) and air pressure have been recorded every second since June 2012, and the gravity value was then calculated from the mass position, using the scale factor of -89.561 micro-gal/V (Sato et al., 2012b). After the removal of tidal gravity changes using the BAYTAP software (Tamura et al., 1991), a gravity change of 4 micro-gal in peak to peak was extracted from the long-term superconducting gravity data from June 2012 to July 2013. Note that this non-tidal gravity change includes the instrumental drift, although the drift rate was very small (less than 1 micro-gal/year) according to the linear regression to the gravity change. We will discuss possible physical mechanisms of the non-tidal gravity change associated with water redistribution, using a hydrological model (e.g., Kazama et al., 2012) and/or long-term weather data. In addition, we also measured absolute gravity values at 6

  7. Reducing the Standard Deviation in Multiple-Assay Experiments Where the Variation Matters but the Absolute Value Does Not

    PubMed Central

    Echenique-Robba, Pablo; Nelo-Bazán, María Alejandra; Carrodeguas, José A.

    2013-01-01

    When the value of a quantity for a number of systems (cells, molecules, people, chunks of metal, DNA vectors, so on) is measured and the aim is to replicate the whole set again for different trials or assays, despite the efforts for a near-equal design, scientists might often obtain quite different measurements. As a consequence, some systems’ averages present standard deviations that are too large to render statistically significant results. This work presents a novel correction method of a very low mathematical and numerical complexity that can reduce the standard deviation of such results and increase their statistical significance. Two conditions are to be met: the inter-system variations of matter while its absolute value does not, and a similar tendency in the values of must be present in the different assays (or in other words, the results corresponding to different assays must present a high linear correlation). We demonstrate the improvements this method offers with a cell biology experiment, but it can definitely be applied to any problem that conforms to the described structure and requirements and in any quantitative scientific field that deals with data subject to uncertainty. PMID:24205158

  8. Intraoperative indocyanine green fluorescence angiography--an objective evaluation of anastomotic perfusion in colorectal surgery.

    PubMed

    Protyniak, Bogdan; Dinallo, Anthony M; Boyan, William P; Dressner, Roy M; Arvanitis, Michael L

    2015-06-01

    The essentials for any bowel anastomosis are: adequate perfusion, tension free, accurate tissue apposition, and minimal local spillage. Traditionally, perfusion is measured by assessing palpable pulses in the mesentery, active bleeding at cut edges, and lack of tissue discoloration. However, subjective methods lack predictive accuracy for an anastomotic leak. We used intraoperative indocyanine green (ICG) fluorescence angiography to objectively assess colon perfusion before a bowel anastomosis. Seventy-seven laparoscopic colorectal operations, between June 2013 and June 2014, were retrospectively reviewed. The perfusion to the colon and ileum was clinically assessed, and then measured using the SPY Elite Imaging System. The absolute value provided an objective number on a 0-256 gray-scale to represent differences in ICG fluorescence intensity. The lowest absolute value was used in data analysis for each anastomosis (including small bowel) to represent the theoretical least perfused/weakest anastomotic area. The lowest absolute value recorded was 20 in a patient who underwent a laparoscopic right hemicolectomy for an adenoma, with no postoperative complications. Four low anterior resection patients had additional segments of descending colon resected. There was one mortality in a patient who underwent a laparoscopic right hemicolectomy. This study illustrates an initial experience with the SPY system in colorectal surgery. The SPY provides an objective, numerical value of bowel perfusion. However, evidence is scant as to the significance of these numbers. Large-scale randomized controlled trials are required to determine specific cutoff values correlated with surgical outcomes, specifically anastomotic leak rates. PMID:26031270

  9. Eosinophil count - absolute

    MedlinePlus

    Eosinophils; Absolute eosinophil count ... the white blood cell count to give the absolute eosinophil count. ... than 500 cells per microliter (cells/mcL). Normal value ranges may vary slightly among different laboratories. Talk ...

  10. Generalized approach for using unbiased symmetric metrics with negative values: normalized mean bias factor and normalized mean absolute error factor

    EPA Science Inventory

    Unbiased symmetric metrics provide a useful measure to quickly compare two datasets, with similar interpretations for both under and overestimations. Two examples include the normalized mean bias factor and normalized mean absolute error factor. However, the original formulations...

  11. Difference in the value of arterial and end-tidal carbon dioxide tension according to different surgical positions: Does it reliably reflect ventilation-perfusion mismatch?

    PubMed Central

    Joo, Jin; Kim, Young Hee; Choi, Jong Ho

    2012-01-01

    Background Body posture, as a gravitational factor, has a clear impact on pulmonary ventilation and perfusion. In lung units with mismatched ventilation and perfusion, gas exchange and/or elimination of carbon dioxide can be impaired. In this situation, differences in the value of arterial and end-tidal carbon dioxide tension [Δ(PaCO2 - PETCO2)] are expected to increase. This study was conducted to observe how Δ(PaCO2 - PETCO2) changed according to the 3 different surgical positions, and to determine whether Δ(PaCO2 - PETCO2) is a reliable predictor of ventilation/perfusion mismatch when a patient is in different postural positions. Methods Fifty-nine patients were divided into either the chronic obstructive pulmonary disease (COPD) group (n = 29) or the non-COPD group (n = 30). PaCO2 and PETCO2 were measured during surgery in the supine, prone, and lateral decubitus positions after a 10 minute stabilization period. The Δ(PaCO2 - PETCO2) were calculated and compared among positions. Results The Δ(PaCO2 - PETCO2) decreased slightly in the prone position and increased significantly in the lateral decubitus position compared with the supine position in both groups. These patterns almost corresponded with the degree of ventilation/perfusion mismatch from the results of the radiological studies. The Δ(PaCO2 - PETCO2) in the COPD group was significantly greater than that in the non-COPD group at all surgical positions. Conclusions Lateral decubitus position is associated with marked increase in Δ(PaCO2 - PETCO2), especially in patients with COPD. The Δ(PaCO2 - PETCO2) is a simple and reliable indicator to predict ventilation/perfusion mismatch at different surgical positions in patients with or without COPD. PMID:23060977

  12. Generalized approach for using unbiased symmetric metrics with negative values: normalized mean bias factor and normalized mean absolute error factor

    SciTech Connect

    Gustafson, William I.; Yu, Shaocai

    2012-10-23

    Unbiased symmetric metrics provide a useful measure to quickly compare two datasets, with similar interpretations for both under and overestimations. Two examples include the normalized mean bias factor and normalized mean absolute error factor. However, the original formulations of these metrics are only valid for datasets with positive means. This paper presents a methodology to use and interpret the metrics with datasets that have negative means. The updated formulations give identical results compared to the original formulations for the case of positive means, so researchers are encouraged to use the updated formulations going forward without introducing ambiguity.

  13. Corresponding waist circumference and body mass index values based on 10-year absolute type 2 diabetes risk in an Australian Aboriginal community

    PubMed Central

    Adegbija, Odewumi; Hoy, Wendy E; Wang, Zhiqiang

    2015-01-01

    Objective There is a lack of waist circumference (WC) thresholds to identify Aboriginal individuals at high risk of type 2 diabetes. We generated gender-specific WC values with equivalent 10-year absolute risk of type 2 diabetes as body mass index (BMI) points in an Australian Aboriginal community to contribute to guidelines needed for establishing WC cut-off points for Aboriginals. Research design and methods A cohort of 803 adult participants free from type 2 diabetes in an Aboriginal community was followed up for up to 20 years. We derived WC values with absolute risks equivalent for the development of type 2 diabetes as BMI values (20–35 kg/m2) using the Weibull accelerated failure-time model. Results After a mean follow-up of 15.7 years, 110 participants developed type 2 diabetes. Absolute risk of type 2 diabetes increased as WC increased, ranging from 3.52% (WC=77.5 cm) to 14.14% (WC=119.9 cm) in males, and 5.04% (WC=79.5 cm) to 24.25% (WC=113.7 cm) in females. In males, WC values with same absolute risks of type 2 diabetes as BMI values were 77.5 cm for BMI=20 kg/m2, 91.5 cm for BMI=25 kg/m2 (overweight threshold), 105.7 cm for BMI=30 kg/m2 (obesity threshold) and 119.9 cm for BMI=35 kg/m2. In females, WC values were 79.5 cm for BMI=20 kg/m2, 90.9 cm for BMI=25 kg/m2, 102.3 cm for BMI=30 kg/m2 and 113.7 cm for BMI=35 kg/m2. Interaction between WC and gender was not statistically significant (p=0.53). Conclusions The absolute risk of type 2 diabetes increased with higher WC measured at baseline screening. Males were not significantly different from females in the association between WC and type 2 diabetes. Our findings are useful contributions for future establishment of WC cut-off points for identifying high-risk individuals in Aboriginal people. PMID:26405557

  14. Clinical value and severity of myocardial perfusion defects in asymptomatic diabetic patients with negative or weakly positive exercise treadmill test

    PubMed Central

    Zakavi, Seyed Rasoul; Taherpour, Mehdi; Moossavi, Zohreh; Sadeghi, Ramin; Kakhki, Vahidreza Dabbagh; Rokni, Haleh

    2013-01-01

    Objective: Although coronary artery disease (CAD) is the leading cause of death in type 2 diabetic patients, it is frequently asymptomatic. Myocardial perfusion imaging (MPI) is reported to show ischemia in a significant number of asymptomatic diabetic patients. We studied the prevalence and severity of myocardial perfusion defects in asymptomatic diabetic patients and its clinical impact. Methods and patients: One hundred thirty consecutive asymptomatic patients, aged 35-65 years with type 2 diabetes mellitus and with no history of CAD and no cardiac symptoms were recruited in the study. Echocardiography, electrocardiography (ECG), routine laboratory tests and exercise treadmill test (ETT) were performed and patients with weakly positive or negative ETT underwent Dipyridamole MPI. Patients with positive ETT were referred to coronary angiography. Patients were followed for at least 17 months (mean 21.7 months) and any cardiac event was recorded. Results: We studied 81 female and 49 male patients with mean age of 51.8 years. Negative, weakly positive and positive ETT result was noted in 74.3%, 15% and 10.7% respectively. 75% of patients with positive ETT had coronary artery disease in angiography. Gated myocardial perfusion SPECT was done in 106 patients. MPI showed reversible defect in 26.9% of the patients with a mean summed stress score of 3.3±1.8. Follow up completed in 112 patients and only one patient with abnormal MPI underwent coronary angiography followed by PTCA. No cardiac death, MI, UA or hospital admission occurred among our patients during follow up (17-26 months). Mean stress end diastolic volume (EDV) was significantly higher in patients with reversible defect compared to patients without reversible defect based on MPI findings (62.0±31.6 Vs 48.5±18.4 ml, P=0.04). Blood glucose and HbA1c were significantly higher in patients with ischemia compared to patients without ischemia (P<0.05). Meanwhile the ratio of TG to HDL was 6.06±3.2 in ischemic

  15. WE-G-18C-02: Estimation of Optimal B-Value Set for Obtaining Apparent Diffusion Coefficient Free From Perfusion in Non-Small Cell Lung Cancer

    SciTech Connect

    Karki, K; Hugo, G; Ford, J; Saraiya, S; Weiss, E; Olsen, K; Groves, R

    2014-06-15

    Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADCIVIM) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm and 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADCIVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADCIVIM, perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADCIVIM(p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADCIVIM, respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADCIVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets

  16. The warm and cold neutral phase in the local interstellar medium at absolute value of B greater than or equal to 10 deg

    NASA Astrophysics Data System (ADS)

    Poppel, W. G. L.; Marronetti, P.; Benaglia, P.

    1994-07-01

    We made a systematic separation of both the neutral phases using the atlases of 21-cm profiles of Heiles & Habing (1974) and Colomb et al. (1980), complemented with other data. First, we fitted the emission of the warm neutral medium (WNM) by means of a broad Gaussian curve (velocity dispersion sigma approximately 10-14 km/s). We derived maps of the column densities NWH and the radial velocities VW of the WNM. Its overall distribution appears to be very inhomogeneous with a large hole in the range b greater than or equal to +50 deg. However, if the hole is excluded, the mean latitude-profiles admit a rough cosec absolute value of b-fit common to both hemispheres. A kinematical analysis of VW for the range 10 deg less than or equal to absolute value of b less than or equal to 40 deg indicates a mean differential rotation with a small nodal deviation. At absolute value of b greater than 50 deg VW is negative, with larger values and discontinuities in the north. On the mean, sigma increases for absolute value of b decreasing, as is expected from differential rotation. From a statistical study of the peaks of the residual profiles we derived some characteristics of the cold neutral medium (CNM). The latter is generally characterized by a single component of sigma approximately 2-6 km/s. Additionally we derived the sky-distribution of the column densities NCH and the radial velocities VC of the CNM within bins of 1.2 deg sec b x 1 deg in l, b. Furthermore, we focused on the characteristics of Linblad's feature A of cool gas by considering the narrow ridge of local H I, which appears in the b-V contour maps at fixed l (e.g. Schoeber 1976). The ridge appears to be the main component of the CNM. We suggest a scenario for the formulation and evolution of the Gould belt system of stars and gas on the basis of an explosive event within a shingle of cold dense gas tilted to the galactic plane. The scenario appears to be consistent with the results found for both the neutral

  17. Absolute Cerebral Blood Flow Infarction Threshold for 3-Hour Ischemia Time Determined with CT Perfusion and 18F-FFMZ-PET Imaging in a Porcine Model of Cerebral Ischemia

    PubMed Central

    Cockburn, Neil; Kovacs, Michael

    2016-01-01

    CT Perfusion (CTP) derived cerebral blood flow (CBF) thresholds have been proposed as the optimal parameter for distinguishing the infarct core prior to reperfusion. Previous threshold-derivation studies have been limited by uncertainties introduced by infarct expansion between the acute phase of stroke and follow-up imaging, or DWI lesion reversibility. In this study a model is proposed for determining infarction CBF thresholds at 3hr ischemia time by comparing contemporaneously acquired CTP derived CBF maps to 18F-FFMZ-PET imaging, with the objective of deriving a CBF threshold for infarction after 3 hours of ischemia. Endothelin-1 (ET-1) was injected into the brain of Duroc-Cross pigs (n = 11) through a burr hole in the skull. CTP images were acquired 10 and 30 minutes post ET-1 injection and then every 30 minutes for 150 minutes. 370 MBq of 18F-FFMZ was injected ~120 minutes post ET-1 injection and PET images were acquired for 25 minutes starting ~155–180 minutes post ET-1 injection. CBF maps from each CTP acquisition were co-registered and converted into a median CBF map. The median CBF map was co-registered to blood volume maps for vessel exclusion, an average CT image for grey/white matter segmentation, and 18F-FFMZ-PET images for infarct delineation. Logistic regression and ROC analysis were performed on infarcted and non-infarcted pixel CBF values for each animal that developed infarct. Six of the eleven animals developed infarction. The mean CBF value corresponding to the optimal operating point of the ROC curves for the 6 animals was 12.6 ± 2.8 mL·min-1·100g-1 for infarction after 3 hours of ischemia. The porcine ET-1 model of cerebral ischemia is easier to implement then other large animal models of stroke, and performs similarly as long as CBF is monitored using CTP to prevent reperfusion. PMID:27347877

  18. Mapping the microvascular and the associated absolute values of oxy-hemoglobin concentration through turbid media via local off-set diffuse optical imaging

    NASA Astrophysics Data System (ADS)

    Chen, Chen; Klämpfl, Florian; Stelzle, Florian; Schmidt, Michael

    2014-11-01

    An imging resolution of micron-scale has not yet been discovered by diffuse optical imaging (DOI), while a superficial response was eliminated. In this work, we report on a new approach of DOI with a local off-set alignment to subvert the common boundary conditions of the modified Beer-Lambert Law (MBLL). It can resolve a superficial target in micron scale under a turbid media. To validate both major breakthroughs, this system was used to recover a subsurface microvascular mimicking structure under an skin equivalent phantom. This microvascular was included with oxy-hemoglobin solution in variant concentrations to distiguish the absolute values of CtRHb and CtHbO2 . Experimental results confirmed the feasibility of recovering the target vascular of 50 µm in diameter, and graded the values of the concentrations of oxy-hemoglobin from 10 g/L to 50 g/L absolutely. Ultimately, this approach could evolve into a non-invasive imaging system to map the microvascular pattern and the associated oximetry under a human skin in-vivo.

  19. Measurement of the B-->pi l nu branching fraction and determination of absolute value of V(ub) with tagged B mesons.

    PubMed

    Aubert, B; Barate, R; Bona, M; Boutigny, D; Couderc, F; Karyotakis, Y; Lees, J P; Poireau, V; Tisserand, V; Zghiche, A; Grauges, E; Palano, A; Chen, J C; Qi, N D; Rong, G; Wang, P; Zhu, Y S; Eigen, G; Ofte, I; Stugu, B; Abrams, G S; Battaglia, M; Brown, D N; Button-Shafer, J; Cahn, R N; Charles, E; Gill, M S; Groysman, Y; Jacobsen, R G; Kadyk, J A; Kerth, L T; Kolomensky, Yu G; Kukartsev, G; Lynch, G; Mir, L M; Orimoto, T J; Pripstein, M; Roe, N A; Ronan, M T; Wenzel, W A; del Amo Sanchez, P; Barrett, M; Ford, K E; Harrison, T J; Hart, A J; Hawkes, C M; Morgan, S E; Watson, A T; Held, T; Koch, H; Lewandowski, B; Pelizaeus, M; Peters, K; Schroeder, T; Steinke, M; Boyd, J T; Burke, J P; Cottingham, W N; Walker, D; Cuhadar-Donszelmann, T; Fulsom, B G; Hearty, C; Knecht, N S; Mattison, T S; McKenna, J A; Khan, A; Kyberd, P; Saleem, M; Sherwood, D J; Teodorescu, L; Blinov, V E; Bukin, A D; Druzhinin, V P; Golubev, V B; Onuchin, A P; Serednyakov, S I; Skovpen, Yu I; Solodov, E P; Todyshev, K Yu; Best, D S; Bondioli, M; Bruinsma, M; Chao, M; Curry, S; Eschrich, I; Kirkby, D; Lankford, A J; Lund, P; Mandelkern, M; Mommsen, R K; Roethel, W; Stoker, D P; Abachi, S; Buchanan, C; Foulkes, S D; Gary, J W; Long, O; Shen, B C; Wang, K; Zhang, L; Hadavand, H K; Hill, E J; Paar, H P; Rahatlou, S; Sharma, V; Berryhill, J W; Campagnari, C; Cunha, A; Dahmes, B; Hong, T M; Kovalskyi, D; Richman, J D; Beck, T W; Eisner, A M; Flacco, C J; Heusch, C A; Kroseberg, J; Lockman, W S; Nesom, G; Schalk, T; Schumm, B A; Seiden, A; Spradlin, P; Williams, D C; Wilson, M G; Albert, J; Chen, E; Dvoretskii, A; Fang, F; Hitlin, D G; Narsky, I; Piatenko, T; Porter, F C; Ryd, A; Samuel, A; Mancinelli, G; Meadows, B T; Mishra, K; Sokoloff, M D; Blanc, F; Bloom, P C; Chen, S; Ford, W T; Hirschauer, J F; Kreisel, A; Nagel, M; Nauenberg, U; Olivas, A; Ruddick, W O; Smith, J G; Ulmer, K A; Wagner, S R; Zhang, J; Chen, A; Eckhart, E A; Soffer, A; Toki, W H; Wilson, R J; Winklmeier, F; Zeng, Q; Altenburg, D D; Feltresi, E; Hauke, A; Jasper, H; Petzold, A; Spaan, B; Brandt, T; Klose, V; Lacker, H M; Mader, W F; Nogowski, R; Schubert, J; Schubert, K R; Schwierz, R; Sundermann, J E; Volk, A; Bernard, D; Bonneaud, G R; Grenier, P; Latour, E; Thiebaux, Ch; Verderi, M; Clark, P J; Gradl, W; Muheim, F; Playfer, S; Robertson, A I; Xie, Y; Andreotti, M; Bettoni, D; Bozzi, C; Calabrese, R; Cibinetto, G; Luppi, E; Negrini, M; Petrella, A; Piemontese, L; Prencipe, E; Anulli, F; Baldini-Ferroli, R; Calcaterra, A; de Sangro, R; Finocchiaro, G; Pacetti, S; Patteri, P; Peruzzi, I M; Piccolo, M; Rama, M; Zallo, A; Buzzo, A; Capra, R; Contri, R; Lo Vetere, M; Macri, M M; Monge, M R; Passaggio, S; Patrignani, C; Robutti, E; Santroni, A; Tosi, S; Brandenburg, G; Chaisanguanthum, K S; Morii, M; Wu, J; Dubitzky, R S; Marks, J; Schenk, S; Uwer, U; Bard, D J; Bhimji, W; Bowerman, D A; Dauncey, P D; Egede, U; Flack, R L; Nash, J A; Nikolich, M B; Panduro Vazquez, W; Behera, P K; Chai, X; Charles, M J; Mallik, U; Meyer, N T; Ziegler, V; Cochran, J; Crawley, H B; Dong, L; Eyges, V; Meyer, W T; Prell, S; Rosenberg, E I; Rubin, A E; Gritsan, A V; Denig, A G; Fritsch, M; Schott, G; Arnaud, N; Davier, M; Grosdidier, G; Höcker, A; Le Diberder, F; Lepeltier, V; Lutz, A M; Oyanguren, A; Pruvot, S; Rodier, S; Roudeau, P; Schune, M H; Stocchi, A; Wang, W F; Wormser, G; Cheng, C H; Lange, D J; Wright, D M; Chavez, C A; Forster, I J; Fry, J R; Gabathuler, E; Gamet, R; George, K A; Hutchcroft, D E; Payne, D J; Schofield, K C; Touramanis, C; Bevan, A J; Di Lodovico, F; Menges, W; Sacco, R; Cowan, G; Flaecher, H U; Hopkins, D A; Jackson, P S; McMahon, T R; Ricciardi, S; Salvatore, F; Wren, A C; Brown, D N; Davis, C L; Allison, J; Barlow, N R; Barlow, R J; Chia, Y M; Edgar, C L; Lafferty, G D; Naisbit, M T; Williams, J C; Yi, J I; Chen, C; Hulsbergen, W D; Jawahery, A; Lae, C K; Roberts, D A; Simi, G; Blaylock, G; Dallapiccola, C; Hertzbach, S S; Li, X; Moore, T B; Saremi, S; Staengle, H; Cowan, R; Sciolla, G; Sekula, S J; Spitznagel, M; Taylor, F; Yamamoto, R K; Kim, H; McLachlin, S E; Patel, P M; Robertson, S H; Lazzaro, A; Lombardo, V; Palombo, F; Bauer, J M; Cremaldi, L; Eschenburg, V; Godang, R; Kroeger, R; Sanders, D A; Summers, D J; Zhao, H W; Brunet, S; Côté, D; Simard, M; Taras, P; Viaud, F B; Nicholson, H; Cavallo, N; De Nardo, G; Fabozzi, F; Gatto, C; Lista, L; Monorchio, D; Paolucci, P; Piccolo, D; Sciacca, C; Baak, M; Raven, G; Snoek, H L; Jessop, C P; Losecco, J M; Allmendinger, T; Benelli, G; Gan, K K; Honscheid, K; Hufnagel, D; Jackson, P D; Kagan, H; Kass, R; Rahimi, A M; Ter-Antonyan, R; Wong, Q K; Blount, N L; Brau, J; Frey, R; Igonkina, O; Lu, M; Rahmat, R; Sinev, N B; Strom, D; Strube, J; Torrence, E; Gaz, A; Margoni, M; Morandin, M; Pompili, A; Posocco, M; Rotondo, M; Simonetto, F; Stroili, R; Voci, C; Benayoun, M; Chauveau, J; Briand, H; David, P; Del Buono, L; de la Vaissière, Ch; Hamon, O; Hartfiel, B L; John, M J J; Leruste, Ph; Malclès, J; Ocariz, J; Roos, L; Therin, G; Gladney, L; Panetta, J; Biasini, M; Covarelli, R; Angelini, C; Batignani, G; Bettarini, S; Bucci, F; Calderini, G; Carpinelli, M; Cenci, R; Forti, F; Giorgi, M A; Lusiani, A; Marchiori, G; Mazur, M A; Morganti, M; Neri, N; Paoloni, E; Rizzo, G; Walsh, J J; Haire, M; Judd, D; Wagoner, D E; Biesiada, J; Danielson, N; Elmer, P; Lau, Y P; Lu, C; Olsen, J; Smith, A J S; Telnov, A V; Bellini, F; Cavoto, G; D'Orazio, A; del Re, D; Di Marco, E; Faccini, R; Ferrarotto, F; Ferroni, F; Gaspero, M; Li Gioi, L; Mazzoni, M A; Morganti, S; Piredda, G; Polci, F; Safai Tehrani, F; Voena, C; Ebert, M; Schröder, H; Waldi, R; Adye, T; De Groot, N; Franek, B; Olaiya, E O; Wilson, F F; Aleksan, R; Emery, S; Gaidot, A; Ganzhur, S F; Hamel de Monchenault, G; Kozanecki, W; Legendre, M; Vasseur, G; Yèche, Ch; Zito, M; Chen, X R; Liu, H; Park, W; Purohit, M V; Wilson, J R; Allen, M T; Aston, D; Bartoldus, R; Bechtle, P; Berger, N; Claus, R; Coleman, J P; Convery, M R; Cristinziani, M; Dingfelder, J C; Dorfan, J; Dubois-Felsmann, G P; Dujmic, D; Dunwoodie, W; Field, R C; Glanzman, T; Gowdy, S J; Graham, M T; Halyo, V; Hast, C; Hryn'ova, T; Innes, W R; Kelsey, M H; Kim, P; Leith, D W G S; Li, S; Luitz, S; Luth, V; Lynch, H L; MacFarlane, D B; Marsiske, H; Messner, R; Muller, D R; O'Grady, C P; Ozcan, V E; Perazzo, A; Perl, M; Pulliam, T; Ratcliff, B N; Roodman, A; Salnikov, A A; Schindler, R H; Schwiening, J; Snyder, A; Stelzer, J; Su, D; Sullivan, M K; Suzuki, K; Swain, S K; Thompson, J M; Va'vra, J; van Bakel, N; Weaver, M; Weinstein, A J R; Wisniewski, W J; Wittgen, M; Wright, D H; Yarritu, A K; Yi, K; Young, C C; Burchat, P R; Edwards, A J; Majewski, S A; Petersen, B A; Roat, C; Wilden, L; Ahmed, S; Alam, M S; Bula, R; Ernst, J A; Jain, V; Pan, B; Saeed, M A; Wappler, F R; Zain, S B; Bugg, W; Krishnamurthy, M; Spanier, S M; Eckmann, R; Ritchie, J L; Satpathy, A; Schilling, C J; Schwitters, R F; Izen, J M; Lou, X C; Ye, S; Bianchi, F; Gallo, F; Gamba, D; Bomben, M; Bosisio, L; Cartaro, C; Cossutti, F; Della Ricca, G; Dittongo, S; Lanceri, L; Vitale, L; Azzolini, V; Martinez-Vidal, F; Banerjee, Sw; Bhuyan, B; Brown, C M; Fortin, D; Hamano, K; Kowalewski, R; Nugent, I M; Roney, J M; Sobie, R J; Back, J J; Harrison, P F; Latham, T E; Mohanty, G B; Pappagallo, M; Band, H R; Chen, X; Cheng, B; Dasu, S; Datta, M; Flood, K T; Hollar, J J; Kutter, P E; Mellado, B; Mihalyi, A; Pan, Y; Pierini, M; Prepost, R; Wu, S L; Yu, Z; Neal, H

    2006-11-24

    We report a measurement of the B-->pi l nu branching fraction based on 211 fb(-1) of data collected with the BABAR detector. We use samples of B0 and B+ mesons tagged by a second B meson reconstructed in a semileptonic or hadronic decay and combine the results assuming isospin symmetry to obtain B(B(0)-->pi- l+ nu) = (1.33+/-0.17stat+/-0.11syst) x 10(-4). We determine the magnitude of the Cabibbo-Kobayashi-Maskawa matrix element absolute value V(ub) by combining the partial branching fractions measured in ranges of the momentum transfer squared and theoretical calculations of the form factor. Using a recent lattice QCD calculation, we find absolute value V(ub) = (4.5+/-0.5stat+/-0.3syst(+0.7) -0.5FF x 10(-3), where the last error is due to the normalization of the form factor. PMID:17155736

  20. Absolute biological needs.

    PubMed

    McLeod, Stephen

    2014-07-01

    Absolute needs (as against instrumental needs) are independent of the ends, goals and purposes of personal agents. Against the view that the only needs are instrumental needs, David Wiggins and Garrett Thomson have defended absolute needs on the grounds that the verb 'need' has instrumental and absolute senses. While remaining neutral about it, this article does not adopt that approach. Instead, it suggests that there are absolute biological needs. The absolute nature of these needs is defended by appeal to: their objectivity (as against mind-dependence); the universality of the phenomenon of needing across the plant and animal kingdoms; the impossibility that biological needs depend wholly upon the exercise of the abilities characteristic of personal agency; the contention that the possession of biological needs is prior to the possession of the abilities characteristic of personal agency. Finally, three philosophical usages of 'normative' are distinguished. On two of these, to describe a phenomenon or claim as 'normative' is to describe it as value-dependent. A description of a phenomenon or claim as 'normative' in the third sense does not entail such value-dependency, though it leaves open the possibility that value depends upon the phenomenon or upon the truth of the claim. It is argued that while survival needs (or claims about them) may well be normative in this third sense, they are normative in neither of the first two. Thus, the idea of absolute need is not inherently normative in either of the first two senses. PMID:23586876

  1. Comparison of high energy gamma rays from absolute value of b greater than 30 deg with the galactic neutral hydrogen distribution

    NASA Technical Reports Server (NTRS)

    Ozel, M. E.; Ogelman, H.; Tumer, T.; Fichtel, C. E.; Hartman, R. C.; Kniffen, D. A.; Thompson, F. J.

    1978-01-01

    High-energy gamma-ray (energy above 35 MeV) data from the SAS 2 satellite have been used to compare the intensity distribution of gamma rays with that of neutral hydrogen (H I) density along the line of sight, at high galactic latitudes (absolute values greater than 30 deg). A model has been constructed for the case where the observed gamma-ray intensity has been assumed to be the sum of a galactic component proportional to the H I distribution plus an isotropic extragalactic emission. A chi-squared test of the model parameters indicates that about 30% of the total high-latitude emission may originate within the Galaxy.

  2. Estimation of optimal b-value sets for obtaining apparent diffusion coefficient free from perfusion in non-small cell lung cancer

    NASA Astrophysics Data System (ADS)

    Karki, Kishor; Hugo, Geoffrey D.; Ford, John C.; Olsen, Kathryn M.; Saraiya, Siddharth; Groves, Robert; Weiss, Elisabeth

    2015-10-01

    The purpose of this study was to determine optimal sets of b-values in diffusion-weighted MRI (DW-MRI) for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADCIVIM) in non-small cell lung cancer. Ten subjects had 40 DW-MRI scans before and during radiotherapy in a 1.5 T MRI scanner. Respiratory triggering was applied to the echo-planar DW-MRI with \\text{TR}≈ 4500 ms, TE  =  74 ms, eight b-values of 0-1000 μs μm-2, pixel size  =  1.98× 1.98 mm2, slice thickness  =  6 mm, interslice gap  =  1.2 mm, 7 axial slices and total acquisition time ≈6 min. One or more DW-MRI scans together covered the whole tumour volume. Monoexponential model ADC values using various b-value sets were compared to reference-standard ADCIVIM values using all eight b-values. Intra-scan coefficient of variation (CV) of active tumour volumes was computed to compare the relative noise in ADC maps. ADC values for one pre-treatment DW-MRI scan of each of the 10 subjects were computed using b-value pairs from DW-MRI images synthesized for b-values of 0-2000 μs μm-2 from the estimated IVIM parametric maps and corrupted by various Rician noise levels. The square root of mean of squared error percentage (RMSE) of the ADC value relative to the corresponding ADCIVIM for the tumour volume of the scan was computed. Monoexponential ADC values for the b-value sets of 250 and 1000; 250, 500 and 1000; 250, 650 and 1000; 250, 800 and 1000; and 250-1000 μs μm-2 were not significantly different from ADCIVIM values (p>0.05 , paired t-test). Mean error in ADC values for these sets relative to ADCIVIM were within 3.5%. Intra-scan CVs for these sets were comparable to that for ADCIVIM. The monoexponential ADC values for other sets—0-1000 50-1000 100-1000 500-1000 and 250 and 800 μs μm-2 were significantly different from the ADCIVIM values. From Rician noise simulation

  3. Combined prognostic value of absolute lymphocyte/monocyte ratio in peripheral blood and interim PET/CT results in Hodgkin lymphoma.

    PubMed

    Simon, Zsofia; Barna, S; Miltenyi, Z; Husi, K; Magyari, F; Jona, A; Garai, I; Nagy, Z; Ujj, G; Szerafin, L; Illes, A

    2016-01-01

    Decreased absolute lymphocyte/monocyte ratio (LMR) in peripheral blood has been reported as an unfavorable prognostic marker in Hodgkin lymphoma. We aimed to investigate whether combining LMR and interim PET/CT scan result (PET2) confers stronger prognostic value than PET2 alone. 121 HL patients were investigated. LMR was calculated from a blood sample taken at the time of diagnosis. PET2 was carried out after the second chemotherapy cycle. Survival was calculated using the Kaplan-Meier method and significance was determined by log-rank test. Effect of variants on survival results was examined using univariate and multivariate analyses. Best LMR cut-off value was determined by receiver operating characteristic (ROC) curve. Best LMR cut-off value was 2.11 in the case of our patients (LMR > 2.11: favorable, LMR ≤ 2.11: unfavorable). Overall and progression-free survivals (OS/PFS) were significantly worse both in lower LMR (≤ 2.11) (OS: P = 0.041, PFS: P = 0.044) and PET2 positive groups (OS: P < 0.001, PFS: P < 0.001). In PET2 positive patient group (n = 32) the low LMR result meant a significantly worse OS (0.030) and PFS (0.001). Both LMR and PET2 proved to be independent prognostic factors on multivariate analysis, and strengthened each other's effect. PMID:26462809

  4. Absolute Zero

    NASA Astrophysics Data System (ADS)

    Donnelly, Russell J.; Sheibley, D.; Belloni, M.; Stamper-Kurn, D.; Vinen, W. F.

    2006-12-01

    Absolute Zero is a two hour PBS special attempting to bring to the general public some of the advances made in 400 years of thermodynamics. It is based on the book “Absolute Zero and the Conquest of Cold” by Tom Shachtman. Absolute Zero will call long-overdue attention to the remarkable strides that have been made in low-temperature physics, a field that has produced 27 Nobel Prizes. It will explore the ongoing interplay between science and technology through historical examples including refrigerators, ice machines, frozen foods, liquid oxygen and nitrogen as well as much colder fluids such as liquid hydrogen and liquid helium. A website has been established to promote the series: www.absolutezerocampaign.org. It contains information on the series, aimed primarily at students at the middle school level. There is a wealth of material here and we hope interested teachers will draw their student’s attention to this website and its substantial contents, which have been carefully vetted for accuracy.

  5. Value of Perfusion-Weighted MR Imaging in the Assessment of Early Cerebral Alterations in Neurologically Asymptomatic HIV-1-Positive and HCV-Positive Patients

    PubMed Central

    Bladowska, Joanna; Knysz, Brygida; Zimny, Anna; Małyszczak, Krzysztof; Kołtowska, Anna; Szewczyk, Paweł; Gąsiorowski, Jacek; Furdal, Michał; Sąsiadek, Marek J.

    2014-01-01

    Background and Purpose Asymptomatic central nervous system (CNS) involvement occurs in the early stage of the human immunodeficiency virus (HIV) infection. It has been documented that the hepatitis C virus (HCV) can replicate in the CNS. The aim of the study was to evaluate early disturbances in cerebral microcirculation using magnetic resonance (MR) perfusion-weighted imaging (PWI) in asymptomatic HIV-1-positive and HCV-positive patients, as well as to assess the correlation between PWI measurements and the clinical data. Materials and Methods Fifty-six patients: 17 HIV-1-positive non-treated, 18 HIV-1-positive treated with combination antiretroviral therapy (cART), 7 HIV-1/HCV-positive non-treated, 14 HCV-positive before antiviral therapy and 18 control subjects were enrolled in the study. PWI was performed with a 1.5T MR unit using dynamic susceptibility contrast (DSC) method. Cerebral blood volume (CBV) measurements relative to cerebellum (rCBV) were evaluated in the posterior cingulated region (PCG), basal ganglia (BG), temporoparietal (TPC) and frontal cortices (FC), as well as in white matter of frontoparietal areas. Correlations of rCBV values with immunologic data and liver histology activity index (HAI) were analyzed. Results Significantly lower rCBV values were found in the right TPC and left FC as well as in PCG in HIV-1-positive naïve (p = 0.009; p = 0.020; p = 0.012), HIV-1 cART treated (p = 0.007; p = 0.009; p = 0.033), HIV-1/HCV-positive (p = 0.007; p = 0.027; p = 0.045) and HCV-positive patients (p = 0.010; p = 0.005; p = 0.045) compared to controls. HIV-1-positive cART treated and HIV-1/HCV-positive patients demonstrated lower rCBV values in the right FC (p = 0.009; p = 0.032, respectively) and the left TPC (p = 0.036; p = 0.005, respectively), while HCV-positive subjects revealed lower rCBV values in the left TPC region (p = 0.003). We found significantly elevated rCBV values in

  6. Prognostic value of thallium-201 myocardial perfusion imaging in patients with unstable angina who respond to medical treatment

    SciTech Connect

    Brown, K.A. )

    1991-04-01

    Although the prognostic value of thallium-201 imaging is well established, its ability to risk stratify patients who present with unstable angina is unclear. Fifty-two consecutive patients admitted with unstable angina who responded to medical treatment and underwent stress thallium-201 imaging within 1 week of discharge were studied. Patients were followed up for 39 +/- 11 months. Cardiac events included cardiac death (n = 3), nonfatal myocardial infarction (n = 4) and admission for unstable angina or revascularization (n = 17). The ability of thallium-201 data (redistribution, fixed defects, normal) to predict cardiac events was compared with clinical data (age, gender, prior myocardial infarction, anginal syndrome, rest and stress electrocardiogram) and cardiac catheterization data using logistic regression. Thallium-201 redistribution was the only significant predictor of cardiac death or nonfatal myocardial infarction (p less than 0.05). The number of myocardial segments with thallium-201 redistribution (p less than 0.0005) and a history of prior myocardial infarction (p less than 0.05) were the only significant predictors of all cardiac events. Cardiac death or nonfatal myocardial infarction occurred more frequently in patients with thallium-201 redistribution (6 (26%) of 23) than in those without redistribution (1 (3%) of 29, p less than 0.05). Similarly, total cardiac events developed more frequently in patients with thallium-201 redistribution (p less than 0.001). Stress thallium-201 imaging has important prognostic value in patients admitted with unstable angina who respond to medical therapy and can identify subgroups at high versus low risk for future cardiac events.

  7. Absolute Summ

    NASA Astrophysics Data System (ADS)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  8. The predictive value of chronic kidney disease for assessing cardiovascular events under consideration of pretest probability for coronary artery disease in patients who underwent stress myocardial perfusion imaging.

    PubMed

    Furuhashi, Tatsuhiko; Moroi, Masao; Joki, Nobuhiko; Hase, Hiroki; Masai, Hirofumi; Kunimasa, Taeko; Fukuda, Hiroshi; Sugi, Kaoru

    2013-02-01

    Pretest probability of coronary artery disease (CAD) facilitates diagnosis and risk stratification of CAD. Stress myocardial perfusion imaging (MPI) and chronic kidney disease (CKD) are established major predictors of cardiovascular events. However, the role of CKD to assess pretest probability of CAD has been unclear. This study evaluates the role of CKD to assess the predictive value of cardiovascular events under consideration of pretest probability in patients who underwent stress MPI. Patients with no history of CAD underwent stress MPI (n = 310; male = 166; age = 70; CKD = 111; low/intermediate/high pretest probability = 17/194/99) and were followed for 24 months. Cardiovascular events included cardiac death and nonfatal acute coronary syndrome. Cardiovascular events occurred in 15 of the 310 patients (4.8 %), but not in those with low pretest probability which included 2 CKD patients. In patients with intermediate to high pretest probability (n = 293), multivariate Cox regression analysis identified only CKD [hazard ratio (HR) = 4.88; P = 0.022) and summed stress score of stress MPI (HR = 1.50; P < 0.001) as independent and significant predictors of cardiovascular events. Cardiovascular events were not observed in patients with low pretest probability. In patients with intermediate to high pretest probability, CKD and stress MPI are independent predictors of cardiovascular events considering the pretest probability of CAD in patients with no history of CAD. In assessing pretest probability of CAD, CKD might be an important factor for assessing future cardiovascular prognosis. PMID:22806318

  9. A full-dimensional model of ozone forming reaction: the absolute value of the recombination rate coefficient, its pressure and temperature dependencies.

    PubMed

    Teplukhin, Alexander; Babikov, Dmitri

    2016-07-28

    Rigorous calculations of scattering resonances in ozone are carried out for a broad range of rotational excitations. The accurate potential energy surface of Dawes is adopted, and a new efficient method for calculations of ro-vibrational energies, wave functions and resonance lifetimes is employed (which uses hyper-spherical coordinates, the sequential diagonalization/truncation approach, grid optimization and complex absorbing potential). A detailed analysis is carried out to characterize distributions of resonance energies and lifetimes, their rotational/vibrational content and their positions with respect to the centrifugal barrier. Emphasis is on the contribution of these resonances to the recombination process that forms ozone. It is found that major contributions come from localized resonances at energies near the top of the barrier. Delocalized resonances at higher energies should also be taken into account, while very narrow resonances at low energies (trapped far behind the centrifugal barrier) should be treated as bound states. The absolute value of the recombination rate coefficient, its pressure and temperature dependencies are obtained using the energy-transfer model developed in the earlier work. Good agreement with experimental data is obtained if one follows the suggestion of Troe, who argued that the energy transfer mechanism of recombination is responsible only for 55% of the recombination rate (with the remaining 45% coming from the competing chaperon mechanism). PMID:27364351

  10. Dynamic chest radiography with a flat-panel detector (FPD): ventilation-perfusion study

    NASA Astrophysics Data System (ADS)

    Tanaka, R.; Sanada, S.; Fujimura, M.; Yasui, M.; Tsuji, S.; Hayashi, N.; Okamoto, H.; Nanbu, Y.; Matsui, O.

    2011-03-01

    Pulmonary ventilation and blood flow are reflected in dynamic chest radiographs as changes in X-ray translucency, i.e., pixel values. This study was performed to investigate the feasibility of ventilation-perfusion (V/Q) study based on the changes in pixel value. Sequential chest radiographs of a patient with ventilation-perfusion mismatch were obtained during respiration using a dynamic flat-panel detector (FPD) system. The lung area was recognized and average pixel value was measured in each area, tracking and deforming the region of interest. Inter-frame differences were then calculated, and the absolute values were summed in each respiratory phase. The results were visualized as ventilation, blood flow, V/Q ratio distribution map and compared to distribution of radioactive counts on ventilation and perfusion scintigrams. In the results, abnormalities were appeared as a reduction of changes in pixel values, and a correlation was observed between the distribution of changes in pixel value and those of radioactivity counts (Ventilation; r=0.78, Perfusion; r=0.77). V/Q mismatch was also indicated as mismatch of changes in pixel value, and a correlation with V/Q calculated by radioactivity counts (r=0.78). These results indicated that the present method is potentially useful for V/Q study as an additional examination in conventional chest radiography.

  11. Comparative value of maximal treadmill testing, exercise thallium myocardial perfusion scintigraphy and exercise radionuclide ventriculography for distinguishing high- and low-risk patients soon after acute myocardial infarction

    SciTech Connect

    Hung, J.; Goris, M.L.; Nash, E.; Kraemer, H.C.; DeBusk, R.F.; Berger, W.E.; Lew, H.

    1984-05-01

    The prognostic value of symptom-limited treadmill exercise electrocardiography, exercise thallium myocardial perfusion scintigraphy and rest and exercise radionuclide ventriculography was compared in 117 men, aged 54 +/- 9 years, tested 3 weeks after a clinically uncomplicated acute myocardial infarction (MI). During a mean follow-up period of 11.6 months, 8 men experienced ''hard'' medical events (cardiac death, nonfatal ventricular fibrillation or recurrent MI) and 14 were hospitalized for unstable angina pectoris, congestive heart failure or coronary bypass surgery (total of 22 combined events). By multivariate analysis (Cox proportional hazards model), peak treadmill work load and the change in left ventricular ejection fraction (EF) during exercise were significant (p less than 0.01) predictors of hard medical events; these 2 risk factors and recurrent ischemic chest pain in the coronary care unit were also significantly predictive (p less than 0.001) for combined events. A peak treadmill work load of 4 METs or less or a decrease in EF of 5% or more below the value at rest during submaximal effort distinguished 22 high-risk patients (20% of the study population) from 89 low-risk patients. The rate of hard medical events within 12 months was 23% (5 of 22 patients), vs 2% (2 of 89 patients) in the high- and low-risk patient subsets, respectively (p less than 0.001). Thus, in patients who underwent evaluation 3 weeks after a clinically uncomplicated MI, exercise radionuclide ventriculography contributed independent prognostic information to that provided by symptom-limited treadmill testing and was superior to exercise thallium scintigraphy for this purpose.

  12. Prognostic Value of Major Cardiac Event Risk Score Estimated With Gated Myocardial Perfusion Imaging in Japanese Patients With Coronary Artery Disease.

    PubMed

    Yoda, Shunichi; Nakanishi, Kanae; Tano, Ayako; Hori, Yusuke; Hayase, Misa; Mineki, Takashi; Suzuki, Yasuyuki; Matsumoto, Naoya; Hirayama, Atsushi

    2016-07-27

    We published a cardiac event risk score (CERS) predicting the risk of major cardiac events (MCEs) within 3 years. The purpose of this study was to verify the prognostic value of the CERS before and after treatment in Japanese patients with coronary artery disease.We retrospectively investigated 612 patients who underwent rest (201)Tl and stress (99m)Tc-tetrofosmin myocardial perfusion single photon emission computed tomography (SPECT) between October 2004 and March 2013 and who had a significant stenosis with ≥ 75% narrowing of the arterial diameter detected by coronary angiography performed after confirmation of ≥ 5% ischemia with the SPECT. The patients underwent treatment including revascularization and medication, and thereafter, were re-evaluated with SPECT during a chronic phase and followed-up to confirm prognosis for ≥ 1 year. The endpoint was the onset of MCEs during the follow-up.During the follow-up (36.7 ± 14.5 months), 50 patients (8.7%) experienced MCEs comprising cardiac death (n = 16), non-fatal myocardial infarction (n = 4), and unstable angina pectoris (n = 30). The multivariate Cox proportional hazards regression model analysis for the actual occurrence of MCEs showed the summed difference score % and MCE risks estimated with the CERS after treatment to be significant independent variables. Ischemic reduction after treatment contributed significantly to a decrease in the MCE risks. The MCE risks estimated with the CERS after treatment were generally consistent with the incidence of the MCEs actually observed.The CERS after treatment is a valuable formula for predicting prognosis in Japanese patients with coronary artery disease. PMID:27357436

  13. Clinical Neuroimaging Using Arterial Spin-Labeled Perfusion MRI

    PubMed Central

    Wolf, Ronald L.; Detre, John A.

    2007-01-01

    SUMMARY The two most common methods for measuring perfusion with MRI are based on dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL). Although clinical experience to date is much more extensive with DSC perfusion MRI, ASL methods offer several advantages. The primary advantages are that completely noninvasive absolute cerebral blood flow (CBF) measurements are possible with relative insensitivity to permeability, and that multiple repeated measurements can be obtained to evaluate one or more interventions or to perform perfusion-based functional MRI. ASL perfusion and perfusion-based fMRI methods have been applied in many clinical settings, including acute and chronic cerebrovascular disease, CNS neoplasms, epilepsy, aging and development, neurodegenerative disorders, and neuropsychiatric diseases. Recent technical advances have improved the sensitivity of ASL perfusion MRI, and increasing use is expected in the coming years. This review focuses on ASL perfusion MRI and applications in clinical neuroimaging. PMID:17599701

  14. Assessment of portal contribution to liver perfusion by quantitative sequential scintigraphy and Doppler ultrasound in alcoholic cirrhosis. Diagnostic value in the detection of portal hypertension.

    PubMed

    Dao, T; Elfadel, S; Bouvard, G; Bouvard, N; Lecointe, I; Jardin-Grimaux, I; Verwaerde, J C; Valla, A

    1993-03-01

    To assess the portal contribution to liver perfusion, we carried out quantitative sequential scintigraphy in 110 patients with alcoholic cirrhosis (22 Child-Pugh class A, 39 class B, 49 class C) and 15 normal subjects. Duplex Doppler ultrasound found a type of intrahepatic circulation that made the standard scintigraphic procedure inaccurate in four cases of cirrhosis, which were reevaluated. Portal contribution to liver perfusion was lower in cirrhotics than in normal subjects (48.7 +/- 29% versus 78.4 +/- 6%; p < 0.001). The sensitivity of scintigraphy in detecting portal hypertension, based on portal contribution < or = 66%, was 61.8% (with a 100% specificity) compared with 66.7% for endoscopy (diagnosis based on existence of varices). The overall sensitivity of the two tests together was 86.1%. Portal contribution to liver perfusion was inversely correlated to Child-Pugh score (r = 0.53; p < 0.001), to prothrombin time (r = 0.52; p < 0.001), and to hepatic venous pressure gradient (r = 0.43; p < 0.001) and positively correlated to albuminemia (r = 0.42; p < 0.001). Concurrent alcoholic hepatitis and the existence of large portosystemic collaterals were related to a decrease in portal contribution to liver perfusion. We conclude that quantitative sequential scintigraphy, which shows a direct relationship between portal contribution to liver perfusion, on the one hand, and the amount of portosystemic shunting, the progression of liver disease, and/or acute liver injury, on the other, could serve as a diagnostic test for portal hypertension. The addition of scintigraphy improves the overall sensitivity of endoscopy. PMID:8463621

  15. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    PubMed

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted. PMID:27245647

  16. Myocardial perfusion imaging using contrast echocardiography.

    PubMed

    Pathan, Faraz; Marwick, Thomas H

    2015-01-01

    Microbubbles are an excellent intravascular tracer, and both the rate of myocardial opacification (analogous to coronary microvascular perfusion) and contrast intensity (analogous to myocardial blood volume) provide unique insights into myocardial perfusion. A strong evidence base has been accumulated to show comparability with nuclear perfusion imaging and incremental diagnostic and prognostic value relative to wall motion analysis. This technique also provides the possibility to measure myocardial perfusion at the bedside. Despite all of these advantages, the technique is complicated, technically challenging, and has failed to scale legislative and financial hurdles. The development of targeted imaging and therapeutic interventions will hopefully rekindle interest in this interesting modality. PMID:25817740

  17. Multimodal imaging in diagnosis of Alzheimer's disease and amnestic mild cognitive impairment: value of magnetic resonance spectroscopy, perfusion, and diffusion tensor imaging of the posterior cingulate region.

    PubMed

    Zimny, Anna; Szewczyk, Pawel; Trypka, Elzbieta; Wojtynska, Renata; Noga, Leszek; Leszek, Jerzy; Sasiadek, Marek

    2011-01-01

    The purpose of this study was to assess metabolic, perfusion, and microstructural changes within the posterior cingulate area in patients with Alzheimer's disease (AD) and amnestic mild cognitive impairment (aMCI) using advanced MR techniques such as: spectroscopy (MRS), perfusion weighted imaging (PWI), and diffusion tensor imaging (DTI). Thirty patients with AD (mean age 71.5 y, MMSE 18), 23 with aMCI (mean age 66 y, MMSE 27.4), and 15 age-matched normal controls (mean age 69 y, MMSE 29.5) underwent conventional MRI followed by MRS, PWI, and DTI on 1.5 Tesla MR unit. Several metabolite ratios (N-acetylaspartate [NAA]/creatine [Cr], choline [Ch]/Cr, myoinositol [mI]/Cr, mI/NAA, mI/Cho) as well as parameters of cerebral blood volume relative to cerebellum and fractional anisotropy were obtained in the posterior cingulate region. The above parameters were correlated with the results of neuropsychological tests. AD patients showed significant abnormalities in all evaluated parameters while subjects with aMCI showed only perfusion and diffusion changes in the posterior cingulate area. Only PWI and DTI measurements revealed significant differences among the three evaluated subject groups. DTI, PWI, and MRS results showed significant correlations with neuropsychological tests. DTI changes correlated with both PWI and MRS abnormalities. Of neuroimaging methods, DTI revealed the highest accuracy in diagnosis of AD and aMCI (0.95, 0.79) followed by PWI (0.87, 0.67) and MRS (0.82, 0.47), respectively. In conclusion, AD is a complex pathology regarding both grey and white matter. DTI seems to be the most useful imaging modality to distinguish between AD, aMCI, and control group, followed by PWI and MRS. PMID:21841260

  18. Pulmonary ventilation/perfusion scan

    MedlinePlus

    V/Q scan; Ventilation/perfusion scan; Lung ventilation/perfusion scan ... A pulmonary ventilation/perfusion scan is actually two tests. They may be done separately or together. During the perfusion scan, a health ...

  19. The added value of hybrid ventilation/perfusion SPECT/CT in patients with stable COPD or apparently healthy smokers. Cancer-suspected CT findings in the lungs are common when hybrid imaging is used.

    PubMed

    Jögi, Jonas; Markstad, Hanna; Tufvesson, Ellen; Bjermer, Leif; Bajc, Marika

    2015-01-01

    Ventilation/perfusion (V/P) single-photon emission computed tomography (SPECT) is recognized as a diagnostic method with potential beyond the diagnosis of pulmonary embolism. V/P SPECT identifies functional impairment in diseases such as heart failure (HF), pneumonia, and chronic obstructive pulmonary disease (COPD). The development of hybrid SPECT/computed tomography (CT) systems, combining functional with morphological imaging through the addition of low-dose CT (LDCT), may be useful in COPD, as these patients are prone to lung cancer and other comorbidities. The aim of this study was to investigate the added value of LDCT among healthy smokers and patients with stable COPD, when examined with V/P SPECT/CT hybrid imaging. Sixty-nine subjects, 55 with COPD (GOLD I-IV) and 14 apparently healthy smokers, were examined with V/P SPECT and LDCT hybrid imaging. Spirometry was used to verify COPD grade. Only one apparently healthy smoker and three COPD patients had a normal or nearly normal V/P SPECT. All other patients showed various degrees of airway obstruction, even when spirometry was normal. The same interpretation was reached on both modalities in 39% of the patients. LDCT made V/P SPECT interpretation more certain in 9% of the patients and, in 52%, LDCT provided additional diagnoses. LDCT better characterized the type of emphysema in 12 patients. In 19 cases, tumor-suspected changes were reported. Three of these 19 patients (ie, 4.3% of all subjects) were in the end confirmed to have lung cancer. The majority of LDCT findings were not regarded as clinically significant. V/P SPECT identified perfusion patterns consistent with decompensated left ventricular HF in 14 COPD patients. In 16 patients (23%), perfusion defects were observed. HF and perfusion defects were not recognized with LDCT. In COPD patients and long-time smokers, hybrid imaging had added value compared to V/P SPECT alone, by identifying patients with lung malignancy and more clearly identifying

  20. Determination of absolute value of quantum efficiency of radiation in high quality GaN single crystals using an integrating sphere

    NASA Astrophysics Data System (ADS)

    Kojima, Kazunobu; Ohtomo, Tomomi; Ikemura, Ken-ichiro; Yamazaki, Yoshiki; Saito, Makoto; Ikeda, Hirotaka; Fujito, Kenji; Chichibu, Shigefusa F.

    2016-07-01

    Omnidirectional photoluminescence (ODPL) measurement using an integrating sphere was carried out to absolutely quantify the quantum efficiency of radiation ( η) in high quality GaN single crystals. The total numbers of photons belonging to photoluminescence (PL photons) and photons belonging to an excitation source (excitation photons) were simultaneously counted in the measurement, and η was defined as a ratio of the number of PL photons to the number of absorbed excitation photons. The ODPL spectra near the band edge commonly showed a two-peak structure, which originates from the sharp absorption edge of GaN. A methodology for quantifying internal quantum efficiency ( ηint ) from such experimentally obtained η is derived. A record high ηint of typically 15% is obtained for a freestanding GaN crystal grown by hydride vapor phase epitaxy on a GaN seed crystal synthesized by the ammonothermal method using an acidic mineralizer, when the excitation photon energy and power density were 3.81 eV and 60 W/cm2, respectively.

  1. Diagnostic value of a new myocardial perfusion agent, teboroxime (SQ 30,217), utilizing a rapid planar imaging protocol: Preliminary results

    SciTech Connect

    Hendel, R.C.; McSherry, B.; Karimeddini, M.; Leppo, J.A. )

    1990-10-01

    Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patient positioning technique and a rapid dynamic acquisition protocol, 30 patients underwent planar imaging with teboroxime while at rest and after maximal treadmill exercise. Postexercise scans were completed in an average time (mean +/- SD) of 4.4 +/- 1.6 min, with 4.8 +/- 1.5 min for the views at rest. These results were compared with coronary arteriography or thallium scintigraphy after treadmill exercise, or both. Diagnostic agreement (abnormal versus normal) was present in 28 of the 30 patients (p less than 0.001). Regarding physiologic assessment as compared with thallium scintigraphy, the finding of infarction and ischemia was concordant in 89% and 86% of patients, respectively. This report describes the initial use of teboroxime with a rapid dynamic planar imaging technique, resulting in a high correlation with exercise thallium scintigraphy. Delayed postexercise images obtained 5 to 10 min after exercise demonstrated rapid disappearance of exercise-induced defects noted on the initial (0 to 5 min) postexercise views. The rapid differential washout with teboroxime has not been previously described and the possible clinical significance is discussed.

  2. Diagnostic value of a new myocardial perfusion agent, teboroxime (SO 30,217), utilizing a rapid planar imaging protocol: Preliminary results

    SciTech Connect

    Hendel, R.C.; McSherry, B.; Karimeddini, M.; Leppo, J.A. )

    1990-11-01

    Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patient positioning technique and a rapid dynamic acquisition protocol, 30 patients underwent planar imaging with teboroxoime while at rest and after maximal treadmill exercise. Postexercise scans were completed in an average time (mean +/- SD) of 4.4 +/- 1.6 min, with 4.8 +/- 1.5 min for the views at rest. These results were compared with coronary arteriography or thallium scintigraphy after treadmill exercise, or both. Diagnostic agreement (abnormal versus normal) was present in 28 of the 30 patients (p less than 0.001). Regarding physiologic assessment as compared with thallium scintigraphy, the finding of infarction and ischemia was concordant in 89% and 86% of patients, respectively. This report describes the initial use of teboroxime with a rapid dynamic planar imaging technique, resulting in a high correlation with exercise thallium scintigraphy. Delayed postexercise images obtained 5 to 10 min after exercise demonstrated rapid disappearance of exercise-induced defects noted on the initial (0 to 5 min) postexercise views. The rapid differential washout with teboroxime has not been previously described and the possible clinical significance is discussed.

  3. Absolute Equilibrium Entropy

    NASA Technical Reports Server (NTRS)

    Shebalin, John V.

    1997-01-01

    The entropy associated with absolute equilibrium ensemble theories of ideal, homogeneous, fluid and magneto-fluid turbulence is discussed and the three-dimensional fluid case is examined in detail. A sigma-function is defined, whose minimum value with respect to global parameters is the entropy. A comparison is made between the use of global functions sigma and phase functions H (associated with the development of various H-theorems of ideal turbulence). It is shown that the two approaches are complimentary though conceptually different: H-theorems show that an isolated system tends to equilibrium while sigma-functions allow the demonstration that entropy never decreases when two previously isolated systems are combined. This provides a more complete picture of entropy in the statistical mechanics of ideal fluids.

  4. TU-A-12A-09: Absolute Blood Flow Measurement in a Cardiac Phantom Using Low Dose CT

    SciTech Connect

    Ziemer, B; Hubbard, L; Lipinski, J; Molloi, S

    2014-06-15

    Purpose: To investigate a first pass analysis technique to measure absolute flow from low dose CT images in a cardiac phantom. This technique can be combined with a myocardial mass assignment to yield absolute perfusion using only two volume scans and reduce the radiation dose to the patient. Methods: A four-chamber cardiac phantom and perfusion chamber were constructed from poly-acrylic and connected with tubing to approximate anatomical features. The system was connected to a pulsatile pump, input/output reservoirs and power contrast injector. Flow was varied in the range of 1-2.67 mL/s with the pump operating at 60 beats/min. The system was imaged once a second for 14 seconds with a 320-row scanner (Toshiba Medical Systems) using a contrast-enhanced, prospective-gated cardiac perfusion protocol. Flow was calculated by the following steps: subsequent images of the perfusion volume were subtracted to find the contrast entering the volume; this was normalized by an upstream, known volume region to convert Hounsfield (HU) values to concentration; this was divided by the subtracted images time difference. The technique requires a relatively stable input contrast concentration and no contrast can leave the perfusion volume before the flow measurement is completed. Results: The flow calculated from the images showed an excellent correlation with the known rates. The data was fit to a linear function with slope 1.03, intercept 0.02 and an R{sup 2} value of 0.99. The average root mean square (RMS) error was 0.15 mL/s and the average standard deviation was 0.14 mL/s. The flow rate was stable within 7.7% across the full scan and served to validate model assumptions. Conclusion: Accurate, absolute flow rates were measured from CT images using a conservation of mass model. Measurements can be made using two volume scans which can substantially reduce the radiation dose compared with current dynamic perfusion techniques.

  5. Comparison of cerebral tissue oxygenation values in full term and preterm newborns by the simultaneous use of two near-infrared spectroscopy devices: an absolute and a relative trending oximeter

    NASA Astrophysics Data System (ADS)

    Szczapa, Tomasz; Karpiński, Łukasz; Moczko, Jerzy; Weindling, Michael; Kornacka, Alicja; Wróblewska, Katarzyna; Adamczak, Aleksandra; Jopek, Aleksandra; Chojnacka, Karolina; Gadzinowski, Janusz

    2013-08-01

    The aim of this study is to compare a two-wavelength light emitting diode-based tissue oximeter (INVOS), which is designed to show trends in tissue oxygenation, with a four-wavelength laser-based oximeter (FORE-SIGHT), designed to deliver absolute values of tissue oxygenation. Simultaneous values of cerebral tissue oxygenation (StO2) are measured using both devices in 15 term and 15 preterm clinically stable newborns on the first and third day of life. Values are recorded simultaneously in two periods between which oximeter sensor positions are switched to the contralateral side. Agreement between StO2 values before and after the change of sensor position is analyzed. We find that mean cerebral StO2 values are similar between devices for term and preterm babies, but INVOS shows StO2 values spread over a wider range, with wider standard deviations than shown by the FORE-SIGHT. There is relatively good agreement with a bias up to 3.5% and limits of agreement up to 11.8%. Measurements from each side of the forehead show better repeatability for the FORE-SIGHT monitor. We conclude that performance of the two devices is probably acceptable for clinical purposes. Both performed sufficiently well, but the use of FORE-SIGHT may be associated with tighter range and better repeatability of data.

  6. Discovery of Cepheids in NGC 5253: Absolute peak brightness of SN Ia 1895B and SN Ia 1972E and the value of H(sub 0)

    NASA Technical Reports Server (NTRS)

    Saha, A.; Sandage, Allan; Labhardt, Lukas; Schwengeler, Hans; Tammann, G. A.; Panagia, N.; Macchetto, F. D.

    1995-01-01

    Observations of the Hubble Space Telescope (HST) between 1993 May 31 and 1993 July 19 in 20 epochs in the F555W passband and five epochs in the F785LP passband have led to the discovery of 14 Cepheids in the Amorphous galaxy NGC 5253. The apparent V distance modulus is (m-M)(sub AV) = 28.08 +/- 0.10 determined from the 12 Cepheids with normal amplitudes. The distance modulus using the F785LP data is consistent with the V value to within the errors. Five methods used to determine the internal reddening are consistent with zero differential reddening, accurate to a level of E(B-V) less than 0.05 mag, over the region occupied by Cepheids and the two supernovae (SNe) produced by NGC 5253. The apparent magnitudes at maximum for the two SNe in NGC 5253 are adopted as B(sub max) = 8.33 +/- 0.2 mag for SN 1895B, and B(sub max) = 8.56 +/- 0.1 and V(sub max) = 8.60 +/- 0.1 for SN 1972E which is a prototype SN of Type Ia. The apparent magnitude system used by Walker (1923) for SN 1859B has been corrected to the modern B scale and zero point to determine its adopted B(sub max) value.

  7. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-05-15

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  8. Absolute nuclear material assay

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  9. Absolute instability of the Gaussian wake profile

    NASA Technical Reports Server (NTRS)

    Hultgren, Lennart S.; Aggarwal, Arun K.

    1987-01-01

    Linear parallel-flow stability theory has been used to investigate the effect of viscosity on the local absolute instability of a family of wake profiles with a Gaussian velocity distribution. The type of local instability, i.e., convective or absolute, is determined by the location of a branch-point singularity with zero group velocity of the complex dispersion relation for the instability waves. The effects of viscosity were found to be weak for values of the wake Reynolds number, based on the center-line velocity defect and the wake half-width, larger than about 400. Absolute instability occurs only for sufficiently large values of the center-line wake defect. The critical value of this parameter increases with decreasing wake Reynolds number, thereby indicating a shrinking region of absolute instability with decreasing wake Reynolds number. If backflow is not allowed, absolute instability does not occur for wake Reynolds numbers smaller than about 38.

  10. Absolute Income, Relative Income, and Happiness

    ERIC Educational Resources Information Center

    Ball, Richard; Chernova, Kateryna

    2008-01-01

    This paper uses data from the World Values Survey to investigate how an individual's self-reported happiness is related to (i) the level of her income in absolute terms, and (ii) the level of her income relative to other people in her country. The main findings are that (i) both absolute and relative income are positively and significantly…

  11. Perfusion magnetic resonance imaging correlates of neuropsychological impairment in multiple sclerosis

    PubMed Central

    Inglese, Matilde; Adhya, Sumita; Johnson, Glyn; Babb, James S; Miles, Laura; Jaggi, Hina; Herbert, Joseph; Grossman, Robert I

    2008-01-01

    Although cognitive impairment is common in multiple sclerosis (MS), its pathophysiology is still poorly understood. Abnormalities of cerebral blood flow (CBF) have long been acknowledged in MS and advances in perfusion magnetic resonance imaging (MRI) allow for their assessment in vivo. We investigated the relationship between regional perfusion changes and neuropsychological (NP) dysfunctions in patients with relapsing-remitting and primary-progressive MS. Absolute CBF, cerebral blood volume (CBV) and mean transit time were measured in 32 MS patients and 11 healthy controls using dynamic susceptibility contrast-enhanced T2*-weighted MRI. A comprehensive NP test battery was administered to all patients. A mixed model analysis of covariance was performed for group comparisons in terms of perfusion measures in normal-appearing white matter (NAWM) and deep gray matter (GM). Pearson’s correlations were used to describe the association of perfusion metrics with NP Z-scores. CBF and CBV values were significantly decreased in both NAWM and deep GM in MS patients compared with controls (P = 0.01). In all patients, deep GM CBF was significantly associated with Rey Complex Figure Test (RCFT)-Copy (r = 0.5; P = 0.001) and deep GM CBV and NAWM CBV were significantly associated with Color-Word Interference Inhibition Switching test (D-KEFSIS) (r = 0.4; P = 0.008 and r = 0.4; P = 0.02). However, the only associations that remained significant after Bonferroni correction were between deep GM CBF and RCFT-Copy (P = 0.006), and deep GM CBV and D-KEFSIS (P = 0.04). Our results suggest a role for tissue perfusion impairment in NP dysfunction in MS. Large-scale studies are needed to characterize better this association. PMID:17473851

  12. A Phantom Tissue System for the Calibration of Perfusion Measurements

    PubMed Central

    Mudaliar, Ashvinikumar V.; Ellis, Brent E.; Ricketts, Patricia L.; Lanz, Otto I.; Scott, Elaine P.; Diller, Thomas E.

    2008-01-01

    A convenient method for testing and calibrating surface perfusion sensors has been developed. A phantom tissue model is used to simulate the nondirectional blood flow of tissue perfusion. A computational fluid dynamics (CFD) model was constructed in Fluent® to design the phantom tissue and validate the experimental results. The phantom perfusion system was used with a perfusion sensor based on clearance of thermal energy. A heat flux gage measures the heat flux response of tissue when a thermal event (convective cooling) is applied. The blood perfusion and contact resistance are estimated by a parameter estimation code. From the experimental and analytical results, it was concluded that the probe displayed good measurement repeatability and sensitivity. The experimental perfusion measurements in the tissue were in good agreement with those of the CFD models and demonstrated the value of the phantom tissue system. PMID:19045509

  13. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  14. PREOPERATIVE PREDICTION OF LUNG FUNCTION IN PNEUMONECTOMY BY SPIROMETRY AND LUNG PERFUSION SCINTIGRAPHY

    PubMed Central

    Cukic, Vesna

    2012-01-01

    Introduction: Nowadays an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused by common etiologic factor - smoking cigarettes. Loss of lung tissue in such patients can worsen much the postoperative pulmonary function. So it is necessary to asses the postoperative pulmonary function especially after maximal resection, i.e. pneumonectomy. Objective: To check over the accuracy of preoperative prognosis of postoperative lung function after pneumonectomy using spirometry and lung perfusion scinigraphy. Material and methods: The study was done on 17 patients operated at the Clinic for thoracic surgery, who were treated previously at the Clinic for Pulmonary Diseases “Podhrastovi” in the period from 01. 12. 2008. to 01. 06. 2011. Postoperative pulmonary function expressed as ppoFEV1 (predicted postoperative forced expiratory volume in one second) was prognosticated preoperatively using spirometry, i.e.. simple calculation according to the number of the pulmonary segments to be removed and perfusion lung scintigraphy. Results: There is no significant deviation of postoperative achieved values of FEV1 from predicted ones obtained by both methods, and there is no significant differences between predicted values (ppoFEV1) obtained by spirometry and perfusion scintigraphy. Conclusion: It is necessary to asses the postoperative pulmonary function before lung resection to avoid postoperative respiratory failure and other cardiopulmonary complications. It is absolutely necessary for pneumonectomy, i.e.. maximal pulmonary resection. It can be done with great possibility using spirometry or perfusion lung scintigraphy. PMID:23378687

  15. A multi-centennial time series of well-constrained ΔR values for the Irish Sea derived using absolutely-dated shell samples from the mollusc Arctica islandica

    NASA Astrophysics Data System (ADS)

    Butler, P. G.; Scourse, J. D.; Richardson, C. A.; Wanamaker, A. D., Jr.

    2009-04-01

    Determinations of the local correction (ΔR) to the globally averaged marine radiocarbon reservoir age are often isolated in space and time, derived from heterogeneous sources and constrained by significant uncertainties. Although time series of ΔR at single sites can be obtained from sediment cores, these are subject to multiple uncertainties related to sedimentation rates, bioturbation and interspecific variations in the source of radiocarbon in the analysed samples. Coral records provide better resolution, but these are available only for tropical locations. It is shown here that it is possible to use the shell of the long-lived bivalve mollusc Arctica islandica as a source of high resolution time series of absolutely-dated marine radiocarbon determinations for the shelf seas surrounding the North Atlantic ocean. Annual growth increments in the shell can be crossdated and chronologies can be constructed in a precise analogue with the use of tree-rings. Because the calendar dates of the samples are known, ΔR can be determined with high precision and accuracy and because all the samples are from the same species, the time series of ΔR values possesses a high degree of internal consistency. Presented here is a multi-centennial (AD 1593 - AD 1933) time series of 31 ΔR values for a site in the Irish Sea close to the Isle of Man. The mean value of ΔR (-62 14C yrs) does not change significantly during this period but increased variability is apparent before AD 1750.

  16. [Ocular perfusion pressure and its relevance for glaucoma].

    PubMed

    Schmidl, D; Werkmeister, R; Garhöfer, G; Schmetterer, L

    2015-02-01

    Ocular perfusion pressure is defined as the difference between arterial and venous pressure in ocular vessels. In practice, mean arterial pressure is used to substitute for arterial pressure in ocular vessels while intraocular pressure gives an estimate for ocular venous pressure. This results in a value that is easy to calculate and which is of importance since several studies have shown that it is correlated to the prevalence, incidence and progression of primary open angle glaucoma. Today, ocular perfusion pressure is used to estimate individual risks. Since no target value for ocular perfusion pressure can be defined, direct therapeutic intervention is difficult. Still, it has to be kept in mind that lowering intraocular pressure automatically leads to an increase in ocular perfusion pressure. The present article also points out problems and limitations in the concept of ocular perfusion pressure and suggests possible solutions for these problems in the future. PMID:25700252

  17. The absolute path command

    2012-05-11

    The ap command traveres all symlinks in a given file, directory, or executable name to identify the final absolute path. It can print just the final path, each intermediate link along with the symlink chan, and the permissions and ownership of each directory component in the final path. It has functionality similar to "which", except that it shows the final path instead of the first path. It is also similar to "pwd", but it canmore » provide the absolute path to a relative directory from the current working directory.« less

  18. The absolute path command

    SciTech Connect

    Moody, A.

    2012-05-11

    The ap command traveres all symlinks in a given file, directory, or executable name to identify the final absolute path. It can print just the final path, each intermediate link along with the symlink chan, and the permissions and ownership of each directory component in the final path. It has functionality similar to "which", except that it shows the final path instead of the first path. It is also similar to "pwd", but it can provide the absolute path to a relative directory from the current working directory.

  19. Ex vivo lung perfusion.

    PubMed

    Reeb, Jeremie; Cypel, Marcelo

    2016-03-01

    Lung transplantation is an established life-saving therapy for patients with end-stage lung disease. Unfortunately, greater success in lung transplantation is hindered by a shortage of lung donors and the relatively poor early-, mid-, and long-term outcomes associated with severe primary graft dysfunction. Ex vivo lung perfusion has emerged as a modern preservation technique that allows for a more accurate lung assessment and improvement in lung quality. This review outlines the: (i) rationale behind the method; (ii) techniques and protocols; (iii) Toronto ex vivo lung perfusion method; (iv) devices available; and (v) clinical experience worldwide. We also highlight the potential of ex vivo lung perfusion in leading a new era of lung preservation. PMID:26700566

  20. Brain tumors and synchrotron radiation: Methodological developments in quantitative brain perfusion imaging and radiation therapy

    SciTech Connect

    Adam, Jean-Francois

    2005-04-01

    High-grade gliomas are the most frequent type of primary brain tumors in adults. Unfortunately, the management of glioblastomas is still mainly palliative and remains a difficult challenge, despite advances in brain tumor molecular biology and in some emerging therapies. Synchrotron radiation opens fields for medical imaging and radiation therapy by using monochromatic intense x-ray beams. It is now well known that angiogenesis plays a critical role in the tumor growth process and that brain perfusion is representative of the tumor mitotic activity. Synchrotron radiation quantitative computed tomography (SRCT) is one of the most accurate techniques for measuring in vivo contrast agent concentration and thus computing precise and accurate absolute values of the brain perfusion key parameters. The methodological developments of SRCT absolute brain perfusion measurements as well as their preclinical validation are detailed in this thesis. In particular, absolute cerebral volume and blood brain barrier permeability high-resolution (pixel size <50x50 {mu}m{sup 2}) parametric maps were reported. In conventional radiotherapy, the treatment of these tumors remains a delicate challenge, because the damages to the surrounding normal brain tissue limit the amount of radiation that can be delivered. One strategy to overcome this limitation is to infuse an iodinated contrast agent to the patient during the irradiation. The contrast agent accumulates in the tumor, through the broken blood brain barrier, and the irradiation is performed with kilovoltage x rays, in tomography mode, the tumor being located at the center of rotation and the beam size adjusted to the tumor dimensions. The dose enhancement results from the photoelectric effect on the heavy element and from the irradiation geometry. Synchrotron beams, providing high intensity, tunable monochromatic x rays, are ideal for this treatment. The beam properties allow the selection of monochromatic irradiation, at the optimal

  1. Monitoring of intracellular free calcium in perfused rat liver.

    PubMed

    Ruttner, Z; Ligeti, L; Reinlib, L; Hines, K; McLaughlin, A C

    1993-06-01

    Fluorescent calcium indicators have been widely used to assess cytoplasmic calcium concentration in cells. To examine the role of calcium ions on different physiological functions (e.g. in case of liver; bile secretion, glucose metabolism, etc.) there is a need for whole organ studies. We have developed a technique to estimate intracellular free calcium changes in perfused rat liver. Krebs-Henseleit perfused livers were loaded with 7 microM or 35 microM Indo-1/AM. An area 3 mm in diameter and approximately 300 microns in depth was illuminated at 340 nm. Fluorescence was monitored with photomultiplier tubes at 3 wavelengths (400 nm for Ca-bound dye, 504 nm for free dye and 464 nm for NADH). The viability of liver preparations was assessed by measurement of the concentrations of lactate dehydrogenase and alanine aminotransferase in the effluent. Loading of the livers with 7 microM Indo-1/AM via the portal vein resulted in a 5-fold increase of fluorescence at 400 nm. However the dye 'leaked' out of the liver with a half-time of 18 min. Probenecid (a specific anion carrier blocker) inhibited loss of dye in a dose dependent fashion (2.5-10 mM). Transient calcium elevations were observed in response to vasopressin (5-50 nM) at physiological levels, ethanol (0.3-0.8 M) and the calcium ionophore, ionomycin. Certain limitations were apparent with this approach: (1) it was necessary to use an anion carrier blocker to maintain a relatively steady dye concentration; (2) endogenous NADH fluorescence interfered with the calcium signal; and (3) absolute values of calcium concentration could not be determined. PMID:8358770

  2. Distribution of perfusion.

    PubMed

    Glenny, Robb; Robertson, H Thomas

    2011-01-01

    Local driving pressures and resistances within the pulmonary vascular tree determine the distribution of perfusion in the lung. Unlike other organs, these local determinants are significantly influenced by regional hydrostatic and alveolar pressures. Those effects on blood flow distribution are further magnified by the large vertical height of the human lung and the relatively low intravascular pressures in the pulmonary circulation. While the distribution of perfusion is largely due to passive determinants such as vascular geometry and hydrostatic pressures, active mechanisms such as vasoconstriction induced by local hypoxia can also redistribute blood flow. This chapter reviews the determinants of regional lung perfusion with a focus on vascular tree geometry, vertical gradients induced by gravity, the interactions between vascular and surrounding alveolar pressures, and hypoxic pulmonary vasoconstriction. While each of these determinants of perfusion distribution can be examined in isolation, the distribution of blood flow is dynamically determined and each component interacts with the others so that a change in one region of the lung influences the distribution of blood flow in other lung regions. PMID:23737171

  3. Importance of capillary perfusion.

    PubMed

    Hardaway, R M

    1979-11-01

    Perfusion is more critical than oxygen in the maintenance of cell viability. A high hematocrit or high fibrinogen level increases blood viscosity and predisposes to disseminated intravascular coagulation. It is recommended that a hematocrit of about 30 be maintained in periods of circulatory stress such as shock or extracorporeal circulation. PMID:495856

  4. Pattern of Hemodynamic Impairment in Multiple Sclerosis: Dynamic Susceptibility Contrast Perfusion MR Imaging at 3.0 T

    PubMed Central

    Adhya, Sumita; Johnson, Glyn; Herbert, Joseph; Jaggi, Hina; Babb, James S.; Grossman, Robert I.; Inglese, Matilde

    2006-01-01

    This study aimed to determine regional pattern of tissue perfusion in the normal-appearing white matter (NAWM) of patients with primary-progressive (PP), relapsing-remitting (RR) multiple sclerosis (MS) and healthy controls, and to investigate the association between perfusion abnormalities and clinical disability. Using dynamic susceptibility contrast (DSC) perfusion MRI at 3 Tesla, we studied twenty-two patients with clinically definite MS, eleven with PP-MS and eleven with RR-MS and eleven age- and gender-matched healthy volunteers. The MRI protocol included axial dual-echo, dynamic susceptibility contrast enhanced (DSC) T2*-weighted and post-contrast T1-weighted images. Absolute cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) were measured in the periventricular, frontal, occipital NAWM, and in the splenium of the corpus callosum. Compared to controls, CBF and CBV were significantly lower in all NAWM regions in both PP-MS patients (p values from <0.0001 to 0.001) and RR-MS (p values from <0.0001 to 0.020). Compared to RR-MS, PP-MS patients showed significantly lower CBF in the periventricular NAWM (p= 0.002) and lower CBV in the periventricular and frontal NAWM (p values: 0.0029 and 0.022). EDSS was significantly correlated with the periventricular CBF (r=−0.48, p=0.0016) and with the periventricular and frontal CBV (r=−0.42, p=0.015; r=−0.35, p=0.038, respectively). This study suggests that the hemodynamic abnormalities of NAWM have clinical relevance in patients with MS. DSC perfusion MRI might provide a relevant objective measure of disease activity and treatment efficacy. PMID:16996280

  5. Relative indexes of cutaneous blood perfusion measured by real-time laser Doppler imaging (LDI) in healthy volunteers.

    PubMed

    Seyed Jafari, S Morteza; Schawkat, Megir; Van De Ville, Dimitri; Shafighi, Maziar

    2014-07-01

    We used real-time LDI to study regional variations in microcirculatory perfusion in healthy candidates to establish a new methodology for global perfusion body mapping that is based on intra-individual perfusion index ratios. Our study included 74 (37 female) healthy volunteers aged between 22 and 30 years (mean 24.49). Imaging was performed using a recent microcirculation-imaging camera (EasyLDI) for different body regions of each volunteer. The perfusion values were reported in Arbitrary Perfusion Units (APU). The relative perfusion indexes for each candidate's body region were then obtained by normalization with the perfusion value of the forehead. Basic parameters such as weight, height, and blood pressure were also measured and analyzed. The highest mean perfusion value was reported in the forehead area (259.21APU). Mean perfusion in the measured parts of the body correlated positively with mean forehead value, while there was no significant correlation between forehead blood perfusion values and room temperature, BMI, systolic blood pressure and diastolic blood pressure (p=0.420, 0.623, 0.488, 0.099, respectively). Analysis of the data showed that perfusion indexes were not significantly different between male and female volunteers except for the ventral upper arm area (p=.001). LDI is a non-invasive, fast technique that opens several avenues for clinical applications. The mean perfusion indexes are useful in clinical practice for monitoring patients before and after surgical interventions. Perfusion values can be predicted for different body parts for patients only by taking the forehead perfusion value and using the perfusion index ratios to obtain expected normative perfusion values. PMID:24788075

  6. Developing a Benchmarking Process in Perfusion: A Report of the Perfusion Downunder Collaboration

    PubMed Central

    Baker, Robert A.; Newland, Richard F.; Fenton, Carmel; McDonald, Michael; Willcox, Timothy W.; Merry, Alan F.

    2012-01-01

    Abstract: Improving and understanding clinical practice is an appropriate goal for the perfusion community. The Perfusion Downunder Collaboration has established a multi-center perfusion focused database aimed at achieving these goals through the development of quantitative quality indicators for clinical improvement through benchmarking. Data were collected using the Perfusion Downunder Collaboration database from procedures performed in eight Australian and New Zealand cardiac centers between March 2007 and February 2011. At the Perfusion Downunder Meeting in 2010, it was agreed by consensus, to report quality indicators (QI) for glucose level, arterial outlet temperature, and pCO2 management during cardiopulmonary bypass. The values chosen for each QI were: blood glucose ≥4 mmol/L and ≤10 mmol/L; arterial outlet temperature ≤37°C; and arterial blood gas pCO2 ≥ 35 and ≤45 mmHg. The QI data were used to derive benchmarks using the Achievable Benchmark of Care (ABC™) methodology to identify the incidence of QIs at the best performing centers. Five thousand four hundred and sixty-five procedures were evaluated to derive QI and benchmark data. The incidence of the blood glucose QI ranged from 37–96% of procedures, with a benchmark value of 90%. The arterial outlet temperature QI occurred in 16–98% of procedures with the benchmark of 94%; while the arterial pCO2 QI occurred in 21–91%, with the benchmark value of 80%. We have derived QIs and benchmark calculations for the management of several key aspects of cardiopulmonary bypass to provide a platform for improving the quality of perfusion practice. PMID:22730861

  7. Electronic Absolute Cartesian Autocollimator

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.

    2006-01-01

    An electronic absolute Cartesian autocollimator performs the same basic optical function as does a conventional all-optical or a conventional electronic autocollimator but differs in the nature of its optical target and the manner in which the position of the image of the target is measured. The term absolute in the name of this apparatus reflects the nature of the position measurement, which, unlike in a conventional electronic autocollimator, is based absolutely on the position of the image rather than on an assumed proportionality between the position and the levels of processed analog electronic signals. The term Cartesian in the name of this apparatus reflects the nature of its optical target. Figure 1 depicts the electronic functional blocks of an electronic absolute Cartesian autocollimator along with its basic optical layout, which is the same as that of a conventional autocollimator. Referring first to the optical layout and functions only, this or any autocollimator is used to measure the compound angular deviation of a flat datum mirror with respect to the optical axis of the autocollimator itself. The optical components include an illuminated target, a beam splitter, an objective or collimating lens, and a viewer or detector (described in more detail below) at a viewing plane. The target and the viewing planes are focal planes of the lens. Target light reflected by the datum mirror is imaged on the viewing plane at unit magnification by the collimating lens. If the normal to the datum mirror is parallel to the optical axis of the autocollimator, then the target image is centered on the viewing plane. Any angular deviation of the normal from the optical axis manifests itself as a lateral displacement of the target image from the center. The magnitude of the displacement is proportional to the focal length and to the magnitude (assumed to be small) of the angular deviation. The direction of the displacement is perpendicular to the axis about which the

  8. ABSOLUTE POLARIMETRY AT RHIC.

    SciTech Connect

    OKADA; BRAVAR, A.; BUNCE, G.; GILL, R.; HUANG, H.; MAKDISI, Y.; NASS, A.; WOOD, J.; ZELENSKI, Z.; ET AL.

    2007-09-10

    Precise and absolute beam polarization measurements are critical for the RHIC spin physics program. Because all experimental spin-dependent results are normalized by beam polarization, the normalization uncertainty contributes directly to final physics uncertainties. We aimed to perform the beam polarization measurement to an accuracy Of {Delta}P{sub beam}/P{sub beam} < 5%. The absolute polarimeter consists of Polarized Atomic Hydrogen Gas Jet Target and left-right pairs of silicon strip detectors and was installed in the RHIC-ring in 2004. This system features proton-proton elastic scattering in the Coulomb nuclear interference (CNI) region. Precise measurements of the analyzing power A{sub N} of this process has allowed us to achieve {Delta}P{sub beam}/P{sub beam} = 4.2% in 2005 for the first long spin-physics run. In this report, we describe the entire set up and performance of the system. The procedure of beam polarization measurement and analysis results from 2004-2005 are described. Physics topics of AN in the CNI region (four-momentum transfer squared 0.001 < -t < 0.032 (GeV/c){sup 2}) are also discussed. We point out the current issues and expected optimum accuracy in 2006 and the future.

  9. Improvements in the Quantitative Assessment of Cerebral Blood Volume and Flow with the Removal of Vessel Voxels from MR Perfusion Images

    PubMed Central

    Teng, Michael Mu Huo; Cho, I-Chieh; Kao, Yi-Hsuan; Chuang, Chi-Shuo; Chiu, Fang-Ying; Chang, Feng-Chi

    2013-01-01

    Objective. To improve the quantitative assessment of cerebral blood volume (CBV) and flow (CBF) in the brain voxels from MR perfusion images. Materials and Methods. Normal brain parenchyma was automatically segmented with the time-to-peak criteria after cerebrospinal fluid removal and preliminary vessel voxel removal. Two scaling factors were calculated by comparing the relative CBV and CBF of the segmented normal brain parenchyma with the absolute values in the literature. Using the scaling factors, the relative values were converted to the absolute CBV and CBF. Voxels with either CBV > 8 mL/100 g or CBF > 100 mL/100 g/min were characterized as vessel voxels and were excluded from the quantitative measurements. Results. The segmented brain parenchyma with normal perfusion was consistent with the angiographic findings for each patient. We confirmed the necessity of dual thresholds including CBF and CBV for proper removal of vessel voxels. The scaling factors were 0.208 ± 0.041 for CBV, and 0.168 ± 0.037, 0.172 ± 0.037 for CBF calculated using standard and circulant singular value decomposition techniques, respectively. Conclusion. The automatic scaling and vessel removal techniques provide an alternative method for obtaining improved quantitative assessment of CBV and CBF in patients with thromboembolic cerebral arterial disease. PMID:23586033

  10. Implants as absolute anchorage.

    PubMed

    Rungcharassaeng, Kitichai; Kan, Joseph Y K; Caruso, Joseph M

    2005-11-01

    Anchorage control is essential for successful orthodontic treatment. Each tooth has its own anchorage potential as well as propensity to move when force is applied. When teeth are used as anchorage, the untoward movements of the anchoring units may result in the prolonged treatment time, and unpredictable or less-than-ideal outcome. To maximize tooth-related anchorage, techniques such as differential torque, placing roots into the cortex of the bone, the use of various intraoral devices and/or extraoral appliances have been implemented. Implants, as they are in direct contact with bone, do not possess a periodontal ligament. As a result, they do not move when orthodontic/orthopedic force is applied, and therefore can be used as "absolute anchorage." This article describes different types of implants that have been used as orthodontic anchorage. Their clinical applications and limitations are also discussed. PMID:16463910

  11. Low dose CT perfusion using k-means clustering

    NASA Astrophysics Data System (ADS)

    Pisana, Francesco; Henzler, Thomas; Schönberg, Stefan; Klotz, Ernst; Schmidt, Bernhard; Kachelrieß, Marc

    2016-03-01

    We aim at improving low dose CT perfusion functional parameters maps and CT images quality, preserving quantitative information. In a dynamic CT perfusion dataset, each voxel is measured T times, where T is the number of acquired time points. In this sense, we can think about a voxel as a point in a T-dimensional space, where the coordinates of the voxels would be the values of its time attenuation curve (TAC). Starting from this idea, a k-means algorithm was designed to group voxels in K classes. A modified guided time-intensity profile similarity (gTIPS) filter was implemented and applied only for those voxels belonging to the same class. The approach was tested on a digital brain perfusion phantom as well as on clinical brain and body perfusion datasets, and compared to the original TIPS implementation. The TIPS filter showed the highest CNR improvement, but lowest spatial resolution. gTIPS proved to have the best combination of spatial resolution and CNR improvement for CT images, while k-gTIPS was superior to both gTIPS and TIPS in terms of perfusion maps image quality. We demonstrate k-means clustering analysis can be applied to denoise dynamic CT perfusion data and to improve functional maps. Beside the promising results, this approach has the major benefit of being independent from the perfusion model employed for functional parameters calculation. No similar approaches were found in literature.

  12. Measurement of Absolute Arterial Cerebral Blood Volume in Human Brain Without Using a Contrast Agent

    PubMed Central

    Hua, Jun; Qin, Qin; Pekar, James J.; van Zijl, Peter C. M.

    2011-01-01

    Arterial cerebral blood volume (CBVa) is a vital indicator of tissue perfusion and vascular reactivity. We extended the recently developed inflow vascular-space-occupancy (iVASO) MRI technique, which uses spatially selective inversion to suppress the signal from blood flowing into a slice, with a control scan to measure absolute CBVa using CSF for signal normalization. Images were acquired at multiple blood nulling times to account for the heterogeneity of arterial transit times across the brain, from which both CBVa and arterial transit times were quantified. Arteriolar CBVa was determined separately by incorporating velocity-dependent bipolar crusher gradients. Gray matter CBVa values (n = 11) were 2.04 ± 0.27 and 0.76 ± 0.17 ml blood/100 ml tissue without and with crusher gradients (b = 1.8 s/mm2), respectively. Arterial transit times were 671 ± 43 and 785 ± 69 ms, respectively. The arterial origin of the signal was validated by measuring its T2, which was within arterial range. The proposed approach does not require exogenous contrast agent administration, and provides a noninvasive alternative to existing blood volume techniques for mapping absolute CBVa in studies of brain physiology and neurovascular diseases. PMID:21608057

  13. Automated prediction of tissue outcome after acute ischemic stroke in computed tomography perfusion images

    NASA Astrophysics Data System (ADS)

    Vos, Pieter C.; Bennink, Edwin; de Jong, Hugo; Velthuis, Birgitta K.; Viergever, Max A.; Dankbaar, Jan Willem

    2015-03-01

    Assessment of the extent of cerebral damage on admission in patients with acute ischemic stroke could play an important role in treatment decision making. Computed tomography perfusion (CTP) imaging can be used to determine the extent of damage. However, clinical application is hindered by differences among vendors and used methodology. As a result, threshold based methods and visual assessment of CTP images has not yet shown to be useful in treatment decision making and predicting clinical outcome. Preliminary results in MR studies have shown the benefit of using supervised classifiers for predicting tissue outcome, but this has not been demonstrated for CTP. We present a novel method for the automatic prediction of tissue outcome by combining multi-parametric CTP images into a tissue outcome probability map. A supervised classification scheme was developed to extract absolute and relative perfusion values from processed CTP images that are summarized by a trained classifier into a likelihood of infarction. Training was performed using follow-up CT scans of 20 acute stroke patients with complete recanalization of the vessel that was occluded on admission. Infarcted regions were annotated by expert neuroradiologists. Multiple classifiers were evaluated in a leave-one-patient-out strategy for their discriminating performance using receiver operating characteristic (ROC) statistics. Results showed that a RandomForest classifier performed optimally with an area under the ROC of 0.90 for discriminating infarct tissue. The obtained results are an improvement over existing thresholding methods and are in line with results found in literature where MR perfusion was used.

  14. Absolute isotopic abundances of TI in meteorites

    NASA Astrophysics Data System (ADS)

    Niederer, F. R.; Papanastassiou, D. A.; Wasserburg, G. J.

    1985-03-01

    The absolute isotope abundance of Ti has been determined in Ca-Al-rich inclusions from the Allende and Leoville meteorites and in samples of whole meteorites. The absolute Ti isotope abundances differ by a significant mass dependent isotope fractionation transformation from the previously reported abundances, which were normalized for fractionation using 46Ti/48Ti. Therefore, the absolute compositions define distinct nucleosynthetic components from those previously identified or reflect the existence of significant mass dependent isotope fractionation in nature. The authors provide a general formalism for determining the possible isotope compositions of the exotic Ti from the measured composition, for different values of isotope fractionation in nature and for different mixing ratios of the exotic and normal components.

  15. Comparing Quantitative Values of Two Generations of Laser-Assisted Indocyanine Green Dye Angiography Systems: Can We Predict Necrosis?

    PubMed Central

    Fourman, Mitchell S.; Rivara, Andrew; Dagum, Alexander B.; Huston, Tara L.; Ganz, Jason C.; Bui, Duc T.; Khan, Sami U.

    2014-01-01

    Objective: Several devices exist today to assist the intraoperative determination of skin flap perfusion. Laser-Assisted Indocyanine Green Dye Angiography (LAICGA) has been shown to accurately predict mastectomy skin flap necrosis using quantitative perfusion values. The laser properties of the latest LAICGA device (SPY Elite) differ significantly from its predecessor system (SPY 2001), preventing direct translation of previous published data. The purpose of this study was to establish a mathematical relationship of perfusion values between these 2 devices. Methods: Breast reconstruction patients were prospectively enrolled into a clinical trial where skin flap evaluation and excision was based on quantitative SPY Q values previously established in the literature. Initial study patients underwent mastectomy skin flap evaluation using both SPY systems simultaneously. Absolute perfusion unit (APU) values at identical locations on the breast were then compared graphically. Results: 210 data points were identified on the same patients (n = 4) using both SPY systems. A linear relationship (y = 2.9883x + 12.726) was identified with a high level or correlation (R2 = 0.744). Previously published values using SPY 2001 (APU 3.7) provided a value of 23.8 APU on the SPY Elite. In addition, postoperative necrosis in these patients correlated to regions of skin identified with the SPY Elite with APU less than 23.8. Conclusion: Intraoperative comparison of LAICGA systems has provided direct correlation of perfusion values predictive of necrosis that were previously established in the literature. An APU value of 3.7 from the SPY 2001 correlates to a SPY Elite APU value of 23.8. PMID:25525483

  16. Pulmonary ventilation and perfusion studies in lung cancer

    SciTech Connect

    Narabayashi, I.; Otsuka, N.

    1984-02-01

    In 46 patients with bronchogenic carcinoma, the diagnostic significance of pulmonary ventilation images by the continuous inhalation of Kr-81m gas, which has an extremely short half life, was studied in comparison with pulmonary perfusion images with Tc-99m MAA. The data were processed using digital analysis techniques. There were 15 cases with discrepancies between ventilation and perfusion. The V/Q ratios of the affected lung among the 43 patients showed values above 1.2 in nine cases and below 0.8 in six cases. The Kr-81m ventilation and Tc-99m perfusion images were compared before and after radiation therapy in eight patients. It was possible to assess the therapeutic effect on regional ventilation and regional perfusion, which could not be evaluated by chest x-ray alone, under the same conditions of normal breathing.

  17. Lung Ventilation/Perfusion Scan

    MedlinePlus

    ... from the NHLBI on Twitter. What Is a Lung Ventilation/Perfusion Scan? A lung ventilation/perfusion scan, or VQ scan, is a ... that measures air and blood flow in your lungs. A VQ scan most often is used to ...

  18. Absolute neutrino mass measurements

    NASA Astrophysics Data System (ADS)

    Wolf, Joachim

    2011-10-01

    The neutrino mass plays an important role in particle physics, astrophysics and cosmology. In recent years the detection of neutrino flavour oscillations proved that neutrinos carry mass. However, oscillation experiments are only sensitive to the mass-squared difference of the mass eigenvalues. In contrast to cosmological observations and neutrino-less double beta decay (0v2β) searches, single β-decay experiments provide a direct, model-independent way to determine the absolute neutrino mass by measuring the energy spectrum of decay electrons at the endpoint region with high accuracy. Currently the best kinematic upper limits on the neutrino mass of 2.2eV have been set by two experiments in Mainz and Troitsk, using tritium as beta emitter. The next generation tritium β-experiment KATRIN is currently under construction in Karlsruhe/Germany by an international collaboration. KATRIN intends to improve the sensitivity by one order of magnitude to 0.2eV. The investigation of a second isotope (137Rh) is being pursued by the international MARE collaboration using micro-calorimeters to measure the beta spectrum. The technology needed to reach 0.2eV sensitivity is still in the R&D phase. This paper reviews the present status of neutrino-mass measurements with cosmological data, 0v2β decay and single β-decay.

  19. Absolute neutrino mass measurements

    SciTech Connect

    Wolf, Joachim

    2011-10-06

    The neutrino mass plays an important role in particle physics, astrophysics and cosmology. In recent years the detection of neutrino flavour oscillations proved that neutrinos carry mass. However, oscillation experiments are only sensitive to the mass-squared difference of the mass eigenvalues. In contrast to cosmological observations and neutrino-less double beta decay (0v2{beta}) searches, single {beta}-decay experiments provide a direct, model-independent way to determine the absolute neutrino mass by measuring the energy spectrum of decay electrons at the endpoint region with high accuracy.Currently the best kinematic upper limits on the neutrino mass of 2.2eV have been set by two experiments in Mainz and Troitsk, using tritium as beta emitter. The next generation tritium {beta}-experiment KATRIN is currently under construction in Karlsruhe/Germany by an international collaboration. KATRIN intends to improve the sensitivity by one order of magnitude to 0.2eV. The investigation of a second isotope ({sup 137}Rh) is being pursued by the international MARE collaboration using micro-calorimeters to measure the beta spectrum. The technology needed to reach 0.2eV sensitivity is still in the R and D phase. This paper reviews the present status of neutrino-mass measurements with cosmological data, 0v2{beta} decay and single {beta}-decay.

  20. Ex vivo lung perfusion.

    PubMed

    Machuca, Tiago N; Cypel, Marcelo

    2014-08-01

    Lung transplantation (LTx) is an established treatment option for eligible patients with end-stage lung disease. Nevertheless, the imbalance between suitable donor lungs available and the increasing number of patients considered for LTx reflects in considerable waitlist mortality. Among potential alternatives to address this issue, ex vivo lung perfusion (EVLP) has emerged as a modern preservation technique that allows for more accurate lung assessment and also improvement of lung function. Its application in high-risk donor lungs has been successful and resulted in safe expansion of the donor pool. This article will: (I) review the technical details of EVLP; (II) the rationale behind the method; (III) report the worldwide clinical experience with the EVLP, including the Toronto technique and others; (IV) finally, discuss the growing literature on EVLP application for donation after cardiac death (DCD) lungs. PMID:25132972

  1. Ex vivo lung perfusion

    PubMed Central

    Machuca, Tiago N.

    2014-01-01

    Lung transplantation (LTx) is an established treatment option for eligible patients with end-stage lung disease. Nevertheless, the imbalance between suitable donor lungs available and the increasing number of patients considered for LTx reflects in considerable waitlist mortality. Among potential alternatives to address this issue, ex vivo lung perfusion (EVLP) has emerged as a modern preservation technique that allows for more accurate lung assessment and also improvement of lung function. Its application in high-risk donor lungs has been successful and resulted in safe expansion of the donor pool. This article will: (I) review the technical details of EVLP; (II) the rationale behind the method; (III) report the worldwide clinical experience with the EVLP, including the Toronto technique and others; (IV) finally, discuss the growing literature on EVLP application for donation after cardiac death (DCD) lungs. PMID:25132972

  2. Absolute Identification by Relative Judgment

    ERIC Educational Resources Information Center

    Stewart, Neil; Brown, Gordon D. A.; Chater, Nick

    2005-01-01

    In unidimensional absolute identification tasks, participants identify stimuli that vary along a single dimension. Performance is surprisingly poor compared with discrimination of the same stimuli. Existing models assume that identification is achieved using long-term representations of absolute magnitudes. The authors propose an alternative…

  3. Determination of regional myocardial perfusion by x-ray fluorescence.

    PubMed

    Palmer, B M; McInerney, J J

    1990-05-01

    Validation studies were performed to demonstrate the effectiveness of an x-ray induced fluorescence system in quantitating regional myocardial perfusion in vivo. In a series of 13 open-chested canines, x-ray induced fluorescence was used to simultaneously monitor iodine concentration transients which arose in the left ventricular lumen and in the myocardium after the intravenous injection of an iodinated flow tracer. Deconvolution of the recorded transients produced a transfer function from which the mean transit time for the tracer to travel between the left ventricular lumen and the myocardium was calculated. Measurements of regional myocardial perfusion (Q) made by radioactive microspheres were compared with the reciprocals of the mean transit times (MTT-1) and gave a linear correlation (n = 38): MTT-1 = 0.033 + 0.069 Q, r = 0.71. Comparison of the percent change in perfusion (dQ) relative to a control study for each dog with the percent change in the respective reciprocals of the mean transit times (dMTT-1) produced a linear correlation coefficient of r = 0.88 for the regression line dMTT-1 = 0.46 dQ - 10.7. The x-ray induced fluorescence system may provide a minimally invasive means for monitoring iodine concentration transients and determining relative, if not absolute, measures of regional myocardial perfusion. PMID:2345078

  4. Probing absolute spin polarization at the nanoscale.

    PubMed

    Eltschka, Matthias; Jäck, Berthold; Assig, Maximilian; Kondrashov, Oleg V; Skvortsov, Mikhail A; Etzkorn, Markus; Ast, Christian R; Kern, Klaus

    2014-12-10

    Probing absolute values of spin polarization at the nanoscale offers insight into the fundamental mechanisms of spin-dependent transport. Employing the Zeeman splitting in superconducting tips (Meservey-Tedrow-Fulde effect), we introduce a novel spin-polarized scanning tunneling microscopy that combines the probing capability of the absolute values of spin polarization with precise control at the atomic scale. We utilize our novel approach to measure the locally resolved spin polarization of magnetic Co nanoislands on Cu(111). We find that the spin polarization is enhanced by 65% when increasing the width of the tunnel barrier by only 2.3 Å due to the different decay of the electron orbitals into vacuum. PMID:25423049

  5. Asteroid absolute magnitudes and slope parameters

    NASA Technical Reports Server (NTRS)

    Tedesco, Edward F.

    1991-01-01

    A new listing of absolute magnitudes (H) and slope parameters (G) has been created and published in the Minor Planet Circulars; this same listing will appear in the 1992 Ephemerides of Minor Planets. Unlike previous listings, the values of the current list were derived from fits of data at the V band. All observations were reduced in the same fashion using, where appropriate, a single basis default value of 0.15 for the slope parameter. Distances and phase angles were computed for each observation. The data for 113 asteroids was of sufficiently high quality to permit derivation of their H and G. These improved absolute magnitudes and slope parameters will be used to deduce the most reliable bias-corrected asteroid size-frequency distribution yet made.

  6. Absolute photoionization cross sections of atomic oxygen

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.; Pareek, P. N.

    1985-01-01

    The absolute values of photoionization cross sections of atomic oxygen were measured from the ionization threshold to 120 A. An auto-ionizing resonance belonging to the 2S2P4(4P)3P(3Do, 3So) transition was observed at 479.43 A and another line at 389.97 A. The experimental data is in excellent agreement with rigorous close-coupling calculations that include electron correlations in both the initial and final states.

  7. Absolute photoionization cross sections of atomic oxygen

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.; Pareek, P. N.

    1982-01-01

    The absolute values of photoionization cross sections of atomic oxygen were measured from the ionization threshold to 120 A. An auto-ionizing resonance belonging to the 2S2P4(4P)3P(3Do, 3So) transition was observed at 479.43 A and another line at 389.97 A. The experimental data is in excellent agreement with rigorous close-coupling calculations that include electron correlations in both the initial and final states.

  8. Laser interferometry method for absolute measurement of the acceleration of gravity

    NASA Technical Reports Server (NTRS)

    Hudson, O. K.

    1971-01-01

    Gravimeter permits more accurate and precise absolute measurement of g without reference to Potsdam values as absolute standards. Device is basically Michelson laser beam interferometer in which one arm is mass fitted with corner cube reflector.

  9. [Pulmonary ventilation/perfusion ratio].

    PubMed

    Guenard, H

    1987-01-01

    The ratios of ventilatory (V) and perfusion (Q) flow rates in the lung are to a large extent responsible for the efficiency of gas exchange. In a simplified monocompartmental model of the lung, the arterial partial pressure of a given gas (Pa) is a function of several factors: the solubility of this gas in blood, its venous and inspired partial pressures and the V/Q ratio. In a multicompartemental model, the mean arterial partial pressure of the gas is a function of the individual values of Pa in each compartment as well as the distribution of V/Q ratios in the lung and the relationship between the concentration and the partial pressure of the gas. The heterogeneity of the distribution of V/Q results from those of both V and Q. Two factors are mainly responsible for this heterogeneity: the gravity and the morphometric characteristics of bronchi and vessels. V/Q ratios are partially controlled at least in low V/Q compartments since hypoxia in these compartments leads to pulmonary arteriolar vasoconstriction. However lungs V/Q ratios range from 0.1 to 10 with a mode around 1. Age, muscular exercise, posture, accelerations, anesthesia, O2 breathing, pulmonary pathology are factors which may alter the distribution of V/Q ratios. PMID:3332289

  10. Parametric perfusion imaging based on low-cost ultrasound platform.

    PubMed

    Gu, Xiaolin; Zhong, Hui; Wan, Mingxi; Hu, Xiaowen; Lv, Dan; Shen, Liang; Zhang, Xiaomei

    2010-01-01

    In this study, we attempted to implement parametric perfusion imaging to quantify blood perfusion based on modified low-cost ultrasound platform. A novel ultrasound contrast-specific imaging method called pulse-inversion harmonic sum-squared-differences (PIHSSD) was proposed for improving the sensitivity for detecting contrast agents and the accuracy of parametric perfusion imaging, which combined pulse-inversion harmonic (PIH) with pulse-inversion sum-squared-differences (PISSD) threshold-based decision. PIHSSD method just involved simple operations including addition and multiplication and was easy to realize. The sequences of contrast images without logarithmic compression were used to acquire time intensity curves (TICs) from numerous equal-sized regions-of-interest (ROI) covering the entire image plane. Parametric perfusion images were obtained based on the parameters extracted from the TICs, including peak value (PV), area under curve (AUC), mean transit time (MTT), peak value time (PVT), peak width (PW) and climbing rate (CR). Flow phantom was used for validation and the results suggested that PIHSSD method provided 9.6 to 20.3 dB higher contrast-to-tissue ratio (CTR) than PIH method. The results of the experiments of rabbit kidney also showed that the CTR of PIHSSD images was higher than that of PIH images, and the parametric perfusion images based on PIHSSD method provided more accurate quantification of blood perfusion compared with those based on PIH and PISSD methods. It demonstrated that the parametric perfusion imaging achieved good performance though implemented on low-cost ultrasound platform. (E-mail: mxwan@mail.xjtu.edu.cn). PMID:19931972

  11. Hydrostatic determinants of cerebral perfusion

    SciTech Connect

    Wagner, E.M.; Traystman, R.J.

    1986-05-01

    We examined the cerebral blood flow response to alterations in perfusion pressure mediated through decreases in mean arterial pressure, increases in cerebrospinal fluid (CSF) pressure, and increases in jugular venous (JV) pressure in 42 pentobarbital anesthetized dogs. Each of these three pressures was independently controlled. Cerebral perfusion pressure was defined as mean arterial pressure minus JV or CSF pressure, depending on which was greater. Mean hemispheric blood flow was measured with the radiolabeled microsphere technique. Despite 30-mm Hg reductions in mean arterial pressure or increases in CSF or JV pressure, CBF did not change as long as the perfusion pressure remained greater than approximately 60 mm Hg. However, whenever perfusion pressure was reduced to an average of 48 mm Hg, cerebral blood flow decreased 27% to 33%. These results demonstrate the capacity of the cerebral vascular bed to respond similarly to changes in the perfusion pressure gradient obtained by decreasing mean arterial pressure, increasing JV pressure or increasing CSF pressure, and thereby support the above definition of cerebral perfusion pressure.

  12. Complete inhibition of creatine kinase in isolated perfused rat hearts

    SciTech Connect

    Fossel, E.T.; Hoefeler, H.

    1987-01-01

    Transient exposure of an isolated isovolumic perfused rat heart to low concentrations (0.5 mM) of perfusate-born iodoacetamide resulted in complete inhibition of creatine kinase and partial inhibition of glyceraldehyde-3-phosphate dehydrogenase in the heart. At low levels of developed pressure, hearts maintained mechanical function, ATP, and creatine phosphate levels at control values. However, iodoacetamide-inhibited hearts were unable to maintain control values of end diastolic pressure or peak systolic pressure as work load increased. Global ischemia resulted in loss of all ATP without loss of creatine phosphate, indicating lack of active creatine kinase. These results indicate that isovolumic perfused rat hearts are able to maintain normal function and normal levels of high-energy phosphates without active creatine kinase at low levels of developed pressure. /sup 31/P-NMR of the heart was carried out.

  13. CAD of myocardial perfusion

    NASA Astrophysics Data System (ADS)

    Storm, Corstiaan J.; Slump, Cornelis H.

    2007-03-01

    Our purpose is in the automated evaluation of the physiological relevance of lesions in coronary angiograms. We aim to extract as much as possible quantitative information about the physiological condition of the heart from standard angiographic image sequences. Coronary angiography is still the gold standard for evaluating and diagnosing coronary abnormalities as it is able to locate precisely the coronary artery lesions. The dimensions of the stenosis can be assessed nowadays successfully with image processing based Quantitative Coronary Angiography (QCA) techniques. Our purpose is to assess the clinical relevance of the pertinent stenosis. We therefore analyze the myocardial perfusion as revealed in standard angiographic image sequences. In a Region-of-Interest (ROI) on the angiogram (without an overlaying major blood vessel) the contrast is measured as a function of time (the so-called time-density curve). The required hyperemic state of exercise is induced artificially by the injection of a vasodilator drug e.g. papaverine. In order to minimize motion artifacts we select based on the recorded ECG signal end-diastolic images in both a basal and a hyperemic run in the same projection to position the ROI. We present the development of the algorithms together with results of a small study of 20 patients which have been catheterized following the standard protocol.

  14. MR Perfusion Imaging in Acute Ischemic Stroke

    PubMed Central

    Copen, William A.; Schaefer, Pamela W.; Wu, Ona

    2011-01-01

    MR perfusion imaging offers the potential for measuring brain perfusion in acute stroke patients, at a time when treatment decisions based upon these measurements may affect outcomes dramatically. Rapid advancements in both acute stroke therapy and perfusion imaging techniques have resulted in continuing redefinition of the role that perfusion imaging should play in patient management. This review first discusses the basic pathophysiology of acute stroke, with specific attention to alterations in the various perfusion-related parameters that can be studied by MR perfusion imaging. Although these parameters are sometimes treated as somewhat interchangeable, they reveal greatly different information about brain perfusion. Therefore, subsequent discussion of the utility of different kinds of perfusion images focuses on the differences between them, as well as important artifacts that can complicate their interpretation. Finally, research on the continually evolving role of MR perfusion imaging in acute stroke care is summarized. PMID:21640299

  15. Absolute radiometry and the solar constant

    NASA Technical Reports Server (NTRS)

    Willson, R. C.

    1974-01-01

    A series of active cavity radiometers (ACRs) are described which have been developed as standard detectors for the accurate measurement of irradiance in absolute units. It is noted that the ACR is an electrical substitution calorimeter, is designed for automatic remote operation in any environment, and can make irradiance measurements in the range from low-level IR fluxes up to 30 solar constants with small absolute uncertainty. The instrument operates in a differential mode by chopping the radiant flux to be measured at a slow rate, and irradiance is determined from two electrical power measurements together with the instrumental constant. Results are reported for measurements of the solar constant with two types of ACRs. The more accurate measurement yielded a value of 136.6 plus or minus 0.7 mW/sq cm (1.958 plus or minus 0.010 cal/sq cm per min).

  16. Retrograde heart perfusion: the Langendorff technique of isolated heart perfusion.

    PubMed

    Bell, Robert M; Mocanu, Mihaela M; Yellon, Derek M

    2011-06-01

    In the late 19th century, a number of investigators were working on perfecting isolated heart model, but it was Oscar Langendorff who, in 1895, pioneered the isolated perfused mammalian heart. Since that time, the Langendorff preparation has evolved and provided a wealth of data underpinning our understanding of the fundamental physiology of the heart: its contractile function, coronary blood flow regulation and cardiac metabolism. In more recent times, the procedure has been used to probe pathophysiology of ischaemia/reperfusion and disease states, and with the dawn of molecular biology and genetic manipulation, the Langendorff perfused heart has remained a stalwart tool in the study of the impact upon the physiology of the heart by pharmacological inhibitors and targeted deletion or up-regulation of genes and their impact upon intracellular signalling and adaption to clinically relevant stressful stimuli. We present here the basic structure of the Langendorff system and the fundamental experimental rules which warrant a viable heart preparation. In addition, we discuss the use of the isolated retrograde perfused heart in the model of ischaemia-reperfusion injury ex-vivo, and its applicability to other areas of study. The Langendorff perfusion apparatus is highly adaptable and this is reflected not only in the procedure's longevity but also in the number of different applications to which it has been turned. PMID:21385587

  17. Evaluating multi-exposure speckle imaging estimates of absolute autocorrelation times.

    PubMed

    Kazmi, S M Shams; Wu, Rebecca K; Dunn, Andrew K

    2015-08-01

    Multi-exposure speckle imaging (MESI) is a camera-based flow-imaging technique for quantitative blood-flow monitoring by mapping the speckle-contrast dependence on camera exposure duration. The ability of laser speckle contrast imaging to measure the temporal dynamics of backscattered and interfering coherent fields, in terms of the accuracy of autocorrelation measurements, is a major unresolved issue in quantitative speckle flowmetry. MESI fits for a number of parameters including an estimate of the electric field autocorrelation decay time from the imaged speckles. We compare the MESI-determined correlation times in vitro and in vivo with accepted true values from direct temporal measurements acquired with a photon-counting photon-multiplier tube and an autocorrelator board. The correlation times estimated by MESI in vivo remain on average within 14±11% of those obtained from direct temporal autocorrelation measurements, demonstrating that MESI yields highly comparable statistics of the time-varying fields that can be useful for applications seeking not only quantitative blood flow dynamics but also absolute perfusion. PMID:26258378

  18. The National Geodetic Survey absolute gravity program

    NASA Astrophysics Data System (ADS)

    Peter, George; Moose, Robert E.; Wessells, Claude W.

    1989-03-01

    The National Geodetic Survey absolute gravity program will utilize the high precision afforded by the JILAG-4 instrument to support geodetic and geophysical research, which involves studies of vertical motions, identification and modeling of other temporal variations, and establishment of reference values. The scientific rationale of these objectives is given, the procedures used to collect gravity and environmental data in the field are defined, and the steps necessary to correct and remove unwanted environmental effects are stated. In addition, site selection criteria, methods of concomitant environmental data collection and relative gravity observations, and schedule and logistics are discussed.

  19. Absolute method of measuring magnetic susceptibility

    USGS Publications Warehouse

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  20. Absolute transition probabilities of phosphorus.

    NASA Technical Reports Server (NTRS)

    Miller, M. H.; Roig, R. A.; Bengtson, R. D.

    1971-01-01

    Use of a gas-driven shock tube to measure the absolute strengths of 21 P I lines and 126 P II lines (from 3300 to 6900 A). Accuracy for prominent, isolated neutral and ionic lines is estimated to be 28 to 40% and 18 to 30%, respectively. The data and the corresponding theoretical predictions are examined for conformity with the sum rules.-

  1. Dopaminergic Therapy Modulates Cortical Perfusion in Parkinson Disease With and Without Dementia According to Arterial Spin Labeled Perfusion Magnetic Resonance Imaging

    PubMed Central

    Lin, Wei-Che; Chen, Pei-Chin; Huang, Yung-Cheng; Tsai, Nai-Wen; Chen, Hsiu-Ling; Wang, Hung-Chen; Lin, Tsu-Kung; Chou, Kun-Hsien; Chen, Meng-Hsiang; Chen, Yi-Wen; Lu, Cheng-Hsien

    2016-01-01

    Abstract Arterial spin labeling (ASL) magnetic resonance imaging analyses allow for the quantification of altered cerebral blood flow, and provide a novel means of examining the impact of dopaminergic treatments. The authors examined the cerebral perfusion differences among 17 Parkinson disease (PD) patients, 17 PD with dementia (PDD) patients, and 17 healthy controls and used ASL-MRI to assess the effects of dopaminergic therapies on perfusion in the patients. The authors demonstrated progressive widespread cortical hypoperfusion in PD and PDD and robust effects for the dopaminergic therapies. Specifically, dopaminergic medications further decreased frontal lobe and cerebellum perfusion in the PD and PDD groups, respectively. These patterns of hypoperfusion could be related to cognitive dysfunctions and disease severity. Furthermore, desensitization to dopaminergic therapies in terms of cortical perfusion was found as the disease progressed, supporting the concept that long-term therapies are associated with the therapeutic window narrowing. The highly sensitive pharmaceutical response of ASL allows clinicians and researchers to easily and effectively quantify the absolute perfusion status, which might prove helpful for therapeutic planning. PMID:26844450

  2. In-flight absolute radiometric calibration of the thematic mapper

    NASA Technical Reports Server (NTRS)

    Castle, K. R.; Holm, R. G.; Kastner, C. J.; Palmer, J. M.; Slater, P. N.; Dinguirard, M.; Ezra, C. E.; Jackson, R. D.; Savage, R. K.

    1983-01-01

    The TM multispectral scanner system was calibrated in an absolute manner before launch. To determine the temporal changes of the absolute radiometric calibration of the entire system, spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM collections over White Sands, New Mexico. By entering the measured values in an atmospheric radiative transfer program, the radiance levels of the in four of the spectral bands of the TM were determined. Tables show values for the reflectance of snow at White Sands measured by a modular 8 channel radiometer, and values for exoatmospheric irradiance within the TM passbands, calculated for the Earth-Sun distance using a solar radiometer.

  3. Developing a tissue perfusion sensor.

    PubMed

    Harvey, S L R; Parker, K H; O'Hare, D

    2007-01-01

    The development of a electrochemical tissue perfusion sensor is presented. The sensor is a platinum/platinum ring-disc microelectrode that relies on the principle of collector-generator to monitor mass transport within its vicinity. Tissue perfusion is a mass transport mechanism that describes the movement of respiratory gases, nutrients and metabolites in tissue. The sensor's capability of detecting perfusion at the cellular level in a continuous fashion is unique. This sensor will provide insight into the way nutrients and metabolites are transported in tissue especially in cases were perfusion is low such as in wounds or ischemic tissue. We present experimental work for the development and testing of the sensors in vitro. Experimental flow recordings in free steam solutions as well as the flow through tissue-like media are shown. Tests on post operative human tissue are also presented. The sensor's feature such as the continuous recoding capacities, spatial resolution and the measurement range from ml/min to microl/min are highlighted. PMID:18002549

  4. Repeated Positron Emission Tomography-Computed Tomography and Perfusion-Computed Tomography Imaging in Rectal Cancer: Fluorodeoxyglucose Uptake Corresponds With Tumor Perfusion

    SciTech Connect

    Janssen, Marco H.M.; Aerts, Hugo J.W.L.; Buijsen, Jeroen; Lambin, Philippe; Lammering, Guido; Oellers, Michel C.

    2012-02-01

    Purpose: The purpose of this study was to analyze both the intratumoral fluorodeoxyglucose (FDG) uptake and perfusion within rectal tumors before and after hypofractionated radiotherapy. Methods and Materials: Rectal cancer patients, referred for preoperative hypofractionated radiotherapy (RT), underwent FDG-positron emission tomography (PET)-computed tomography (CT) and perfusion-CT (pCT) imaging before the start of hypofractionated RT and at the day of the last RT fraction. The pCT-images were analyzed using the extended Kety model, quantifying tumor perfusion with the pharmacokinetic parameters K{sup trans}, v{sub e}, and v{sub p}. The mean and maximum FDG uptake based on the standardized uptake value (SUV) and transfer constant (K{sup trans}) within the tumor were correlated. Also, the tumor was subdivided into eight subregions and for each subregion the mean and maximum SUVs and K{sup trans} values were assessed and correlated. Furthermore, the mean FDG uptake in voxels presenting with the lowest 25% of perfusion was compared with the FDG uptake in the voxels with the 25% highest perfusion. Results: The mean and maximum K{sup trans} values were positively correlated with the corresponding SUVs ({rho} = 0.596, p = 0.001 and {rho} = 0.779, p < 0.001). Also, positive correlations were found for K{sup trans} values and SUVs within the subregions (mean, {rho} = 0.413, p < 0.001; and max, {rho} = 0.540, p < 0.001). The mean FDG uptake in the 25% highest-perfused tumor regions was significantly higher compared with the 25% lowest-perfused regions (10.6% {+-} 5.1%, p = 0.017). During hypofractionated radiotherapy, stable mean (p = 0.379) and maximum (p = 0.280) FDG uptake levels were found, whereas the mean (p = 0.040) and maximum (p = 0.003) K{sup trans} values were found to significantly increase. Conclusion: Highly perfused rectal tumors presented with higher FDG-uptake levels compared with relatively low perfused tumors. Also, intratumor regions with a high FDG

  5. Sustained ventilation: perfusion imbalance during hemodialysis.

    PubMed

    Milner, L S; Rothberg, A D; Thomson, P D; Stothart, M

    1983-06-01

    Five children between the ages of 6 and 15 years, who required chronic hemodialysis (HD) for renal failure, were studied to evaluate the central and pulmonary effects of HD on gas exchange. Acetate dialysate was used, and dialysate pO2 and pCO2, arterial pO2 and pCO2, endtidal CO2 and minute ventilation were measured pre-HD and 15, 30, 60, 120 and 240 minutes after commencement of HD. Arterial-alveolar CO2 gradient (aADCO2) was calculated to determine the ventilation: perfusion (V/Q) status. Minute ventilation did not change significantly from the pre-HD value of 8.9 +/- 1.1 l/min (mean +/- SD). The aADCO2 increased significantly from 3.2 +/- 3.7 mmHg to 8.4 +/- 2.4 mmHg at 15 mins (p less than .01) and was still elevated at 120 mins. (9.1 +/- 3.4 mmHg, p less than .02). There was a weak but significant inverse relationship between aADCO2 and arterial pO2 (r -0.42, p less than 0.05). The results suggest that, in these children, dialysed at altitude, dialysis-related hypoxemia appears to be the result of a sustained V/Q mismatch, possibly related to a decrease in pulmonary perfusion. PMID:6413444

  6. Diagnosing acute lacunar infarction using CT perfusion.

    PubMed

    Cao, Wenjie; Yassi, Nawaf; Sharma, Gagan; Yan, Bernard; Desmond, Patricia M; Davis, Stephen M; Campbell, Bruce C V

    2016-07-01

    The value of CT perfusion (CTP) in detecting acute lacunar infarcts (LACI) has not been well established. We tested the sensitivity of CTP for LACI. CTP maps of consecutive stroke patients from 2009-2013 were examined. MRI diffusion imaging was used to identify those with LACI. Two stroke neurologists independently evaluated the CTP maps for evidence of a perfusion lesion in a deep perforating artery territory. Cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT) and time to maximum (Tmax) maps were first examined in isolation and then in combination. Inter-observer agreement was measured using Cohen's κ. The lesions identified were later confirmed against the diffusion MRI reference and the sensitivity and specificity of CTP maps calculated. A total of 63 patient scans were analysed. There were 32 patients with MRI-confirmed LACI within the coverage of CTP; 18 in the striatum, 10 thalamic, and four in the corona radiata. Another 31 patients had normal MRI. Inter-rater agreement was good (κ=0.83). Sensitivity (blinded consensus) was highest for MTT (56.2%) compared to Tmax (25%, p<0.001), CBV (9.3%, p=0.021) and CBF (43.7%, p<0.001). MTT maps enable detection of a significant proportion of LACI using CTP. PMID:26899357

  7. Characterizing potential heart agents with an isolated perfused heart system

    SciTech Connect

    Pendleton, D.B.; Sands, H.; Gallagher, B.M.; Camin, L.L.

    1984-01-01

    The authors have used an isolated perfused heart system for characterizing potential myocardial perfusion radiopharamaceuticals. Rabbit or guinea pig (GP) hearts are removed and perfused through the aorta with a blood-free buffer. Heart rate and ventricular pressure are monitored as indices of viability. Tc-99m-MAA is 96-100% retained in these hearts, and Tc-99m human serum albumin shows less than 5% extraction. Tl-201 is 30-40% extracted. It is known that in-vivo, Tc-99m(dmpe)/sub 2/Cl/sub 2//sup +/ is taken up by rabbit heart but not by GP or human heart. Analogous results are obtained with the isolated perfused heart model, where the complex is extracted well by the isolated rabbit heart (24%) but not by the GP heart (<5%). Values are unchanged if human, rabbit or GP blood is mixed and co-injected with the complex. Tc-99m)dmpe)/sub 3//sup +/ is also taken up by rabbit but not by GP hearts in-vivo. However, isolated perfused hearts of both species extract this complex well (45-52%). Heart uptake is diminished to <7% if the complex is pre-equilibrated with human blood. GP blood produces a moderate inhibition (in GP hearts only) and rabbit blood has no effect. This suggests that a human or GP blood factor may have a significant effect on heart uptake of this complex. Tc-99m(CN-t-butyl)/sub 6//sup +/ is taken up well by both rabbit and GP hearts in-vivo, and is extracted 100% by both isolated perfused hearts. Heart retention remains high (73-75%) in the presence of human blood.

  8. Evaluation of CT Perfusion Biomarkers of Tumor Hypoxia

    PubMed Central

    Qi, Qi; Yeung, Timothy Pok Chi; Lee, Ting-Yim; Bauman, Glenn; Crukley, Cathie; Morrison, Laura; Hoffman, Lisa; Yartsev, Slav

    2016-01-01

    Background Tumor hypoxia is associated with treatment resistance to cancer therapies. Hypoxia can be investigated by immunohistopathologic methods but such procedure is invasive. A non-invasive method to interrogate tumor hypoxia is an attractive option as such method can provide information before, during, and after treatment for personalized therapies. Our study evaluated the correlations between computed tomography (CT) perfusion parameters and immunohistopathologic measurement of tumor hypoxia. Methods Wistar rats, 18 controls and 19 treated with stereotactic radiosurgery (SRS), implanted with the C6 glioma tumor were imaged using CT perfusion on average every five days to monitor tumor growth. A final CT perfusion scan and the brain were obtained on average 14 days (8–22 days) after tumor implantation. Tumor hypoxia was detected immunohistopathologically with pimonidazole. The tumor, necrotic, and pimonidazole-positive areas on histology samples were measured. Percent necrotic area and percent hypoxic areas were calculated. Tumor volume (TV), blood flow (BF), blood volume (BV), and permeability-surface area product (PS) were obtained from the CT perfusion studies. Correlations between CT perfusion parameters and histological parameters were assessed by Spearman’s ρ correlation. A Bonferroni-corrected P value < 0.05 was considered significant. Results BF and BV showed significant correlations with percent hypoxic area ρ = -0.88, P < 0.001 and ρ = -0.81, P < 0.001, respectively, for control animals and ρ = -0.7, P < 0.001 and ρ = -0.6, P = 0.003, respectively, for all animals, while TV and BV were correlated (ρ = -0.64, P = 0.01 and ρ = -0.43, P = 0.043, respectively) with percent necrotic area. PS was not correlated with either percent necrotic or percent hypoxic areas. Conclusions Percent hypoxic area provided significant correlations with BF and BV, suggesting that CT perfusion parameters are potential non-invasive imaging biomarkers of tumor

  9. Absolute Antenna Calibration at the US National Geodetic Survey

    NASA Astrophysics Data System (ADS)

    Mader, G. L.; Bilich, A. L.

    2012-12-01

    Geodetic GNSS applications routinely demand millimeter precision and extremely high levels of accuracy. To achieve these accuracies, measurement and instrument biases at the centimeter to millimeter level must be understood. One of these biases is the antenna phase center, the apparent point of signal reception for a GNSS antenna. It has been well established that phase center patterns differ between antenna models and manufacturers; additional research suggests that the addition of a radome or the choice of antenna mount can significantly alter those a priori phase center patterns. For the more demanding GNSS positioning applications and especially in cases of mixed-antenna networks, it is all the more important to know antenna phase center variations as a function of both elevation and azimuth in the antenna reference frame and incorporate these models into analysis software. Determination of antenna phase center behavior is known as "antenna calibration". Since 1994, NGS has computed relative antenna calibrations for more than 350 antennas. In recent years, the geodetic community has moved to absolute calibrations - the IGS adopted absolute antenna phase center calibrations in 2006 for use in their orbit and clock products, and NGS's CORS group began using absolute antenna calibration upon the release of the new CORS coordinates in IGS08 epoch 2005.00 and NAD 83(2011,MA11,PA11) epoch 2010.00. Although NGS relative calibrations can be and have been converted to absolute, it is considered best practice to independently measure phase center characteristics in an absolute sense. Consequently, NGS has developed and operates an absolute calibration system. These absolute antenna calibrations accommodate the demand for greater accuracy and for 2-dimensional (elevation and azimuth) parameterization. NGS will continue to provide calibration values via the NGS web site www.ngs.noaa.gov/ANTCAL, and will publish calibrations in the ANTEX format as well as the legacy ANTINFO

  10. Revisiting absolute and relative judgments in the WITNESS model.

    PubMed

    Fife, Dustin; Perry, Colton; Gronlund, Scott D

    2014-04-01

    The WITNESS model (Clark in Applied Cognitive Psychology 17:629-654, 2003) provides a theoretical framework with which to investigate the factors that contribute to eyewitness identification decisions. One key factor involves the contributions of absolute versus relative judgments. An absolute contribution is determined by the degree of match between an individual lineup member and memory for the perpetrator; a relative contribution involves the degree to which the best-matching lineup member is a better match to memory than the remaining lineup members. In WITNESS, the proportional contributions of relative versus absolute judgments are governed by the values of the decision weight parameters. We conducted an exploration of the WITNESS model's parameter space to determine the identifiability of these relative/absolute decision weight parameters, and compared the results to a restricted version of the model that does not vary the decision weight parameters. This exploration revealed that the decision weights in WITNESS are difficult to identify: Data often can be fit equally well by setting the decision weights to nearly any value and compensating with a criterion adjustment. Clark, Erickson, and Breneman (Law and Human Behavior 35:364-380, 2011) claimed to demonstrate a theoretical basis for the superiority of lineup decisions that are based on absolute contributions, but the relationship between the decision weights and the criterion weakens this claim. These findings necessitate reconsidering the role of the relative/absolute judgment distinction in eyewitness decision making. PMID:23943556

  11. Optomechanics for absolute rotation detection

    NASA Astrophysics Data System (ADS)

    Davuluri, Sankar

    2016-07-01

    In this article, we present an application of optomechanical cavity for the absolute rotation detection. The optomechanical cavity is arranged in a Michelson interferometer in such a way that the classical centrifugal force due to rotation changes the length of the optomechanical cavity. The change in the cavity length induces a shift in the frequency of the cavity mode. The phase shift corresponding to the frequency shift in the cavity mode is measured at the interferometer output to estimate the angular velocity of absolute rotation. We derived an analytic expression to estimate the minimum detectable rotation rate in our scheme for a given optomechanical cavity. Temperature dependence of the rotation detection sensitivity is studied.

  12. The Absolute Spectrum Polarimeter (ASP)

    NASA Technical Reports Server (NTRS)

    Kogut, A. J.

    2010-01-01

    The Absolute Spectrum Polarimeter (ASP) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from 30 GHz to 5 THz. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much greater than 1O(raised to the power of { -3}) and Compton distortion y < 10 (raised to the power of{-6}). We describe the ASP instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

  13. Absolute calibration of optical flats

    DOEpatents

    Sommargren, Gary E.

    2005-04-05

    The invention uses the phase shifting diffraction interferometer (PSDI) to provide a true point-by-point measurement of absolute flatness over the surface of optical flats. Beams exiting the fiber optics in a PSDI have perfect spherical wavefronts. The measurement beam is reflected from the optical flat and passed through an auxiliary optic to then be combined with the reference beam on a CCD. The combined beams include phase errors due to both the optic under test and the auxiliary optic. Standard phase extraction algorithms are used to calculate this combined phase error. The optical flat is then removed from the system and the measurement fiber is moved to recombine the two beams. The newly combined beams include only the phase errors due to the auxiliary optic. When the second phase measurement is subtracted from the first phase measurement, the absolute phase error of the optical flat is obtained.

  14. Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch.

    PubMed

    Lockwood, Geoffrey G; Fung, Nick L S; Jones, J Gareth

    2014-12-01

    We describe a three-compartment model (shunt and two perfused compartments) to analyse the relationship between inspired oxygen (FIO2) and arterial oxygen saturation (SaO2) in terms of pulmonary shunt and ventilation-perfusion ratio (VA/Q). The program was tested using 24 exact datasets, each with six pairs of FIO2 and SaO2 data points with known VA/Q and shunt, generated by a complex calculator of gas exchange. Additional datasets were created by adding noise and rounding the exact sets, and by reducing the number of data points per dataset. The importance of the oxyhaemoglobin dissociation curve and the arterio-venous difference in oxygen content (avDO2) were also tested. Analysis using the three compartment model was more accurate than the two compartment model and less affected by data degradation. The absolute error in shunt estimation was never more than 2.2 % for the exact and rounded datasets, but the error in VA/Q estimation was -29 to 19 % of the true value (10th-90th centiles). The characteristics of the well-ventilated compartment were not determined accurately. At extremes of cardiac output, an assumed value of avDO2 resulted in significant errors. It is probably advantageous to correct for foetal haemoglobin in neonatal datasets. Analysis of FIO2 versus SaO2 datasets using a three compartment model provides accurate estimates of shunt and VA/Q when arterio-venous difference in oxygen content is known. The estimates may have value as objective measures of gas exchange, and as a visual guide for oxygen therapy. PMID:24402641

  15. Using Flat-Panel Perfusion Imaging to Measure Cerebral Hemodynamics

    PubMed Central

    Lin, Chung-Jung; Guo, Wan-Yuo; Chang, Feng-Chi; Hung, Sheng-Che; Chen, Ko-Kung; Yu, Deuerling-Zheng; Wu, Chun-Hsien Frank; Liou, Jy-Kang Adrian

    2016-01-01

    Abstract Flat-detector CT perfusion (FD-CTP) imaging has demonstrated efficacy in qualitatively accessing the penumbra in acute stroke equivalent to that of magnetic resonance perfusion (MRP). The aim of our study was to evaluate the feasibility of quantifying oligemia in the brain in patients with carotid stenosis. Ten patients with unilateral carotid stenosis of >70% were included. All MRPs and FD-CTPs were performed before stenting. Region-of-interests (ROIs) including middle cerebral artery territory at basal ganglia level on both stenotic and contralateral sides were used for quantitative analysis. Relative time to peak (rTTP) was defined as TTP of the stenotic side divided by TTP of the contralateral side, and so as relative cerebral blood volume (rCBV), relative mean transit time (rMTT), and relative cerebral blood flow (rCBF). Absolute and relative TTP, CBV, MTT, CBF between two modalities were compared. For absolute quantitative analysis, the correlation of TTP was highest (r = 0.56), followed by CBV (r = 0.47), MTT (r = 0.47), and CBF (r = 0.43); for relative quantitative analysis, rCBF was the highest (r = 0.79), followed by rTTP (r = 0.75) and rCBV (r = 0.50). We confirmed that relative quantitative assessment of FD-CTP is feasible in chronic ischemic disease. Absolute quantitative measurements between MRP and FD-CTP only expressed moderate correlations. Optimization of acquisitions and algorithms is warranted to achieve better quantification. PMID:27196456

  16. Validation of diffuse correlation spectroscopy for muscle blood flow with concurrent arterial spin labeled perfusion MRI

    NASA Astrophysics Data System (ADS)

    Yu, Guoqiang; Floyd, Thomas F.; Durduran, Turgut; Zhou, Chao; Wang, Jiongjiong; Detre, John A.; Yodh, Arjun G.

    2007-02-01

    Calf blood flow was measured simultaneously in healthy human subjects (n = 7) during cuff inflation and deflation using near-infrared diffuse correlation spectroscopy (DCS) and arterial spin labeled perfusion MRI (ASL-MRI). The DCS and ASL-MRI data exhibited highly correlated absolute and relative dynamic flow responses in each individual (p < 0.001). Peak flow variations during hyperemia were also significantly correlated, though more for relative (p = 0.003) than absolute (p = 0.016) flow. Repeated measurement variation was less than 8% for both modalities. The results provide much needed quantitative blood flow validation of the diffuse optical correlation method in humans.

  17. Characteristics of Misclassified CT Perfusion Ischemic Core in Patients with Acute Ischemic Stroke

    PubMed Central

    Geuskens, Ralph R. E. G.; Borst, Jordi; Lucas, Marit; Boers, A. M. Merel; Berkhemer, Olvert A.; Roos, Yvo B. W. E. M.; van Walderveen, Marianne A. A.; Jenniskens, Sjoerd F. M.; van Zwam, Wim H.; Dippel, Diederik W. J.; Majoie, Charles B. L. M.; Marquering, Henk A.

    2015-01-01

    Background CT perfusion (CTP) is used to estimate the extent of ischemic core and penumbra in patients with acute ischemic stroke. CTP reliability, however, is limited. This study aims to identify regions misclassified as ischemic core on CTP, using infarct on follow-up noncontrast CT. We aim to assess differences in volumetric and perfusion characteristics in these regions compared to areas that ended up as infarct on follow-up. Materials and Methods This study included 35 patients with >100 mm brain coverage CTP. CTP processing was performed using Philips software (IntelliSpace 7.0). Final infarct was automatically segmented on follow-up noncontrast CT and used as reference. CTP and follow-up noncontrast CT image data were registered. This allowed classification of ischemic lesion agreement (core on CTP: rMTT≥145%, aCBV<2.0 ml/100g and infarct on follow-up noncontrast CT) and misclassified ischemic core (core on CTP, not identified on follow-up noncontrast CT) regions. False discovery ratio (FDR), defined as misclassified ischemic core volume divided by total CTP ischemic core volume, was calculated. Absolute and relative CTP parameters (CBV, CBF, and MTT) were calculated for both misclassified CTP ischemic core and ischemic lesion agreement regions and compared using paired rank-sum tests. Results Median total CTP ischemic core volume was 49.7ml (IQR:29.9ml-132ml); median misclassified ischemic core volume was 30.4ml (IQR:20.9ml-77.0ml). Median FDR between patients was 62% (IQR:49%-80%). Median relative mean transit time was 243% (IQR:198%-289%) and 342% (IQR:249%-432%) for misclassified and ischemic lesion agreement regions, respectively. Median absolute cerebral blood volume was 1.59 (IQR:1.43–1.79) ml/100g (P<0.01) and 1.38 (IQR:1.15–1.49) ml/100g (P<0.01) for misclassified ischemic core and ischemic lesion agreement, respectively. All CTP parameter values differed significantly. Conclusion For all patients a considerable region of the CTP ischemic core

  18. Contrast-enhanced perfusion magnetic resonance imaging for head and neck squamous cell carcinoma: a systematic review.

    PubMed

    Noij, Daniel P; de Jong, Marcus C; Mulders, Lieven G M; Marcus, Johannes T; de Bree, Remco; Lavini, Cristina; de Graaf, Pim; Castelijns, Jonas A

    2015-02-01

    This systematic review gives an extensive overview of the current state of perfusion-weighted magnetic resonance imaging (MRI) for head and neck squamous cell carcinoma (HNSCC). Pubmed and Embase were searched for literature until July 2014 assessing the diagnostic and prognostic performance of perfusion-weighted MRI in HNSCC. Twenty-one diagnostic and 12 prognostic studies were included for qualitative analysis. Four studies used a T2(∗) sequence for dynamic susceptibility (DSC)-MRI, 29 studies used T1-based sequences for dynamic contrast enhanced (DCE)-MRI. Included studies suffered from a great deal of heterogeneity in study methods showing a wide range of diagnostic and prognostic performance. Therefore we could not perform any useful meta-analysis. Perfusion-weighted MRI shows potential in some aspects of diagnosing HNSCC and predicting prognosis. Three studies reported significant correlations between hypoxia and tumor heterogeneity in perfusion parameters (absolute correlation coefficient |ρ|>0.6, P<0.05). Two studies reported synergy between perfusion-weighted MRI and positron emission tomography (PET) parameters. Four studies showed a promising role for response prediction early after the start of chemoradiotherapy. In two studies perfusion-weighted MRI was useful in the detection of residual disease. However more research with uniform study and analysis protocols with larger sample sizes is needed before perfusion-weighted MRI can be used in clinical practice. PMID:25467775

  19. Non-Invasive Method of Determining Absolute Intracranial Pressure

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Cantrell, John H., Jr. (Inventor); Hargens, Alan E. (Inventor)

    2004-01-01

    A method is presented for determining absolute intracranial pressure (ICP) in a patient. Skull expansion is monitored while changes in ICP are induced. The patient's blood pressure is measured when skull expansion is approximately zero. The measured blood pressure is indicative of a reference ICP value. Subsequently, the method causes a known change in ICP and measured the change in skull expansion associated therewith. The absolute ICP is a function of the reference ICP value, the known change in ICP and its associated change in skull expansion; and a measured change in skull expansion.

  20. The Preference of Visualization in Teaching and Learning Absolute Value

    ERIC Educational Resources Information Center

    Konyalioglu, Alper Cihan; Aksu, Zeki; Senel, Esma Ozge

    2012-01-01

    Visualization is mostly despised although it complements and--sometimes--guides the analytical process. This study mainly investigates teachers' preferences concerning the use of the visualization method and determines the extent to which they encourage their students to make use of it within the problem-solving process. This study was conducted…

  1. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    PubMed

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions. PMID:26053731

  2. Ex vivo lung graft perfusion.

    PubMed

    Briot, Raphaël; Gennai, Stéphane; Maignan, Maxime; Souilamas, Redha; Pison, Christophe

    2016-04-01

    This review proposes an update of the state of the art and the ongoing clinical trials of ex vivo lung perfusion for lung transplantation in patients. Ex vivo lung perfusion techniques (EVLP) can be used to evaluate a lung graft outside of the body. The goal of EVLP is to study the functional status of lung grafts that were first rejected for transplantation because they did not match all criteria for a conventional transplantation. After an EVLP evaluation, some of these lungs may be requalified for a possible transplantation in patients. This article proposes an overview of the developments of EVLP techniques. During EVLP, the perfusion and ventilation of the isolated lung preparation are very progressive in order to avoid oedema due to ischaemia-reperfusion injuries. Lung evaluation is mainly based on gasometric (PaO2/FiO2) and rheological criteria (low pulmonary arterial resistance). Several series of patients transplanted with EVLP evaluated lungs have been recently published with promising results. EVLP preparations also allow a better understanding of the physiopathology and treatments of ischaemia-reperfusion injuries. Organ procurements from "non-heart-beating" donors will probably require a wider application of these ex vivo techniques. The development of semi-automated systems might facilitate the clinical use of EVLP techniques. PMID:26746565

  3. Intestinal perfusion monitoring using photoplethysmography

    NASA Astrophysics Data System (ADS)

    Akl, Tony J.; Wilson, Mark A.; Ericson, M. Nance; Coté, Gerard L.

    2013-08-01

    In abdominal trauma patients, monitoring intestinal perfusion and oxygen consumption is essential during the resuscitation period. Photoplethysmography is an optical technique potentially capable of monitoring these changes in real time to provide the medical staff with a timely and quantitative measure of the adequacy of resuscitation. The challenges for using optical techniques in monitoring hemodynamics in intestinal tissue are discussed, and the solutions to these challenges are presented using a combination of Monte Carlo modeling and theoretical analysis of light propagation in tissue. In particular, it is shown that by using visible wavelengths (i.e., 470 and 525 nm), the perfusion signal is enhanced and the background contribution is decreased compared with using traditional near-infrared wavelengths leading to an order of magnitude enhancement in the signal-to-background ratio. It was further shown that, using the visible wavelengths, similar sensitivity to oxygenation changes could be obtained (over 50% compared with that of near-infrared wavelengths). This is mainly due to the increased contrast between tissue and blood in that spectral region and the confinement of the photons to the thickness of the small intestine. Moreover, the modeling results show that the source to detector separation should be limited to roughly 6 mm while using traditional near-infrared light, with a few centimeters source to detector separation leads to poor signal-to-background ratio. Finally, a visible wavelength system is tested in an in vivo porcine study, and the possibility of monitoring intestinal perfusion changes is showed.

  4. Validation of Perfusion Quantification with 3D Gradient Echo Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Blood Pool Contrast Agent in Skeletal Swine Muscle

    PubMed Central

    Hindel, Stefan; Sauerbrey, Anika; Maaß, Marc; Maderwald, Stefan; Schlamann, Marc; Lüdemann, Lutz

    2015-01-01

    The purpose of our study was to validate perfusion quantification in a low-perfused tissue by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with shared k-space sampling using a blood pool contrast agent. Perfusion measurements were performed in a total of seven female pigs. An ultrasonic Doppler probe was attached to the right femoral artery to determine total flow in the hind leg musculature. The femoral artery was catheterized for continuous local administration of adenosine to increase blood flow up to four times the baseline level. Three different stable perfusion levels were induced. The MR protocol included a 3D gradient-echo sequence with a temporal resolution of approximately 1.5 seconds. Before each dynamic sequence, static MR images were acquired with flip angles of 5°, 10°, 20°, and 30°. Both static and dynamic images were used to generate relaxation rate and baseline magnetization maps with a flip angle method. 0.1 mL/kg body weight of blood pool contrast medium was injected via a central venous catheter at a flow rate of 5 mL/s. The right hind leg was segmented in 3D into medial, cranial, lateral, and pelvic thigh muscles, lower leg, bones, skin, and fat. The arterial input function (AIF) was measured in the aorta. Perfusion of the different anatomic regions was calculated using a one- and a two-compartment model with delay- and dispersion-corrected AIFs. The F-test for model comparison was used to decide whether to use the results of the one- or two-compartment model fit. Total flow was calculated by integrating volume-weighted perfusion values over the whole measured region. The resulting values of delay, dispersion, blood volume, mean transit time, and flow were all in physiologically and physically reasonable ranges. In 107 of 160 ROIs, the blood signal was separated, using a two-compartment model, into a capillary and an arteriolar signal contribution, decided by the F-test. Overall flow in hind leg muscles, as measured by the

  5. Validation of Perfusion Quantification with 3D Gradient Echo Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Blood Pool Contrast Agent in Skeletal Swine Muscle.

    PubMed

    Hindel, Stefan; Sauerbrey, Anika; Maaß, Marc; Maderwald, Stefan; Schlamann, Marc; Lüdemann, Lutz

    2015-01-01

    The purpose of our study was to validate perfusion quantification in a low-perfused tissue by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with shared k-space sampling using a blood pool contrast agent. Perfusion measurements were performed in a total of seven female pigs. An ultrasonic Doppler probe was attached to the right femoral artery to determine total flow in the hind leg musculature. The femoral artery was catheterized for continuous local administration of adenosine to increase blood flow up to four times the baseline level. Three different stable perfusion levels were induced. The MR protocol included a 3D gradient-echo sequence with a temporal resolution of approximately 1.5 seconds. Before each dynamic sequence, static MR images were acquired with flip angles of 5°, 10°, 20°, and 30°. Both static and dynamic images were used to generate relaxation rate and baseline magnetization maps with a flip angle method. 0.1 mL/kg body weight of blood pool contrast medium was injected via a central venous catheter at a flow rate of 5 mL/s. The right hind leg was segmented in 3D into medial, cranial, lateral, and pelvic thigh muscles, lower leg, bones, skin, and fat. The arterial input function (AIF) was measured in the aorta. Perfusion of the different anatomic regions was calculated using a one- and a two-compartment model with delay- and dispersion-corrected AIFs. The F-test for model comparison was used to decide whether to use the results of the one- or two-compartment model fit. Total flow was calculated by integrating volume-weighted perfusion values over the whole measured region. The resulting values of delay, dispersion, blood volume, mean transit time, and flow were all in physiologically and physically reasonable ranges. In 107 of 160 ROIs, the blood signal was separated, using a two-compartment model, into a capillary and an arteriolar signal contribution, decided by the F-test. Overall flow in hind leg muscles, as measured by the

  6. Ventilation-perfusion scintiscanning in tropical pulmonary eosinophilia.

    PubMed

    Ray, D; Jayachandran, C A

    1993-08-01

    We report the findings of ventilation and perfusion scintiscanning performed in three untreated patients with acute tropical pulmonary eosinophilia (TPE). In a 26-year-old man whose arterial blood gas values were normal, the lung scan showed normal radioactivity. The scintigrams of a 20-year-old woman who had hypoxemia and hypercapnea showed gross ventilation defects of both lungs that were mainly mismatched; changes in the perfusion scan were minimal. Scintiscanning in a 14-year-old girl who had moderate arterial hypoxia and mild hypocapnea, on the other hand, showed ventilation defects in both lungs, more marked in left lung; multiple matching ventilation-perfusion defects were also seen; however, the V/Q defects did not appear to be equally matched. The scintigraphic findings were compatible with arterial blood gas status of the individual patients and consistent with the notion that a disturbed ventilation-perfusion relationship may be responsible for hypoxemia in some of the patients with TPE. PMID:8339640

  7. An Appeal to Standardize CT- and MR-Perfusion.

    PubMed

    Turowski, B; Schramm, P

    2015-10-01

    Multiple treatment options and risk assessment in cerebrovascular diseases are the actual challenges in diagnostic as well as in interventional neuroradiology.Acute ischemic stroke essentially requires rapid detection of the location and extent of infarction and tissue at risk for making treatment decisions. In the acute setting, modern multiparametric perfusion imaging protocols help to determine infarct core and adjacent penumbral tissue, and they enable the estimation of collateral flow of intra- and extracranial arteries. In subacute delayed cerebral ischemia (DCI) after subarachnoid hemorrhage (SAH) or chronic occlusive neurovascular diseases estimation of residual and collateral flow may be even more difficult.Prediction of sufficient or insufficient supply of brain tissue may be essential to balance conservative against interventional therapies. However, so far no established reliable thresholds are available for determining tissue at acute, subacute, chronic progressive, or chronic risk.Reliable and reproducible thresholds require quantitative perfusion measurements with a calibrated instrument. But the measurement instrument is not at all defined-a variety of parameter settings, different algorithms based on multiple assumptions and a wide variety of published normal and pathologic values for perfusion parameters indicate the problem. In the following text, we explain how deep the problem may be enrooted within techniques and algorithms impeding broad use of perfusion for many clinical issues. PMID:26289412

  8. Pulsatile roller pump perfusion is safe in high risk patients.

    PubMed

    Kocakulak, M; Küçükaksu, S; Pişkin, E

    2004-05-01

    In this study, controllability, safety, blood cell depletion, and hemolysis of a pulsatile roller pump in high-risk patients was evaluated. Sarns 8000 roller pump (Sams, Terumo CVS, Ann Arbor, MI, USA) with a pulsatile control module was used as arterial pump in a clinical setting. Forty patients undergoing elective open heart surgery with high-risk either having chronically obstructive pulmonary disease or chronic renal failure were randomly included in the study to be operated on using pulsatile perfusion or non-pulsatile perfusion. Blood samples were withdrawn at induction of anesthesia, at the time of aortic clamping and de-clamping and at 1 hour and 24 hours following cessation of the bypass. Hematocrit and plasma free hemoglobin values were measured. We observed that the pulsatile roller pump perfusion and the extracorporeal circuit used in the clinical study is safe in high-risk patients undergoing cardiopulmonary bypass. We did not face any emboli, hemolysis, or technical problems. Pulsatile roller pump perfusion with Sarns 8000 heart-lung machine is a simple and reliable technique and can be easily applied during open heart surgery. PMID:15202823

  9. A numerical analysis of a focused ultrasound technique to measure perfusion.

    PubMed

    Anderson, G T; Ye, X

    1994-05-01

    A noninvasive technique to measure perfusion using a focused ultrasound heating source and a thermistor placed on the surface of a tissue is proposed. The method is numerically examined in a model of the canine kidney. The perfusion measurement is shown to depend on several transducer and tissue thermal properties. A two level fractional factorial design simulation is used to map out a parameter value combination that maximizes the sensitivity of the measurement. A technique to numerically assess the uncertainty in the measurement due to uncertainties in the tissue and transducer parameter values is also described. The effects of the medulla and a subcapsular surface layer in the kidney are examined. It is determined that the maximum error in the measured perfusion rate due to all the factors considered is 17 percent for a kidney with a nominal perfusion rate of 300 mL/100g-min and a surface layer of 0.04 cm thickness. PMID:8078324

  10. The AFGL absolute gravity program

    NASA Technical Reports Server (NTRS)

    Hammond, J. A.; Iliff, R. L.

    1978-01-01

    A brief discussion of the AFGL's (Air Force Geophysics Laboratory) program in absolute gravity is presented. Support of outside work and in-house studies relating to gravity instrumentation are discussed. A description of the current transportable system is included and the latest results are presented. These results show good agreement with measurements at the AFGL site by an Italian system. The accuracy obtained by the transportable apparatus is better than 0.1 microns sq sec 10 microgal and agreement with previous measurements is within the combined uncertainties of the measurements.

  11. Global absolut gravity reference system as replacement of IGSN 71

    NASA Astrophysics Data System (ADS)

    Wilmes, Herbert; Wziontek, Hartmut; Falk, Reinhard

    2015-04-01

    The determination of precise gravity field parameters is of great importance in a period in which earth sciences are achieving the necessary accuracy to monitor and document global change processes. This is the reason why experts from geodesy and metrology joined in a successful cooperation to make absolute gravity observations traceable to SI quantities, to improve the metrological kilogram definition and to monitor mass movements and smallest height changes for geodetic and geophysical applications. The international gravity datum is still defined by the International Gravity Standardization Net adopted in 1971 (IGSN 71). The network is based upon pendulum and spring gravimeter observations taken in the 1950s and 60s supported by the early free fall absolute gravimeters. Its gravity values agreed in every case to better than 0.1 mGal. Today, more than 100 absolute gravimeters are in use worldwide. The series of repeated international comparisons confirms the traceability of absolute gravity measurements to SI quantities and confirm the degree of equivalence of the gravimeters in the order of a few µGal. For applications in geosciences where e.g. gravity changes over time need to be analyzed, the temporal stability of an absolute gravimeter is most important. Therefore, the proposition is made to replace the IGSN 71 by an up-to-date gravity reference system which is based upon repeated absolute gravimeter comparisons and a global network of well controlled gravity reference stations.

  12. Standardization of the cumulative absolute velocity

    SciTech Connect

    O'Hara, T.F.; Jacobson, J.P. )

    1991-12-01

    EPRI NP-5930, A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set.

  13. Absolute rates of hole transfer in DNA.

    PubMed

    Senthilkumar, Kittusamy; Grozema, Ferdinand C; Guerra, Célia Fonseca; Bickelhaupt, F Matthias; Lewis, Frederick D; Berlin, Yuri A; Ratner, Mark A; Siebbeles, Laurens D A

    2005-10-26

    Absolute rates of hole transfer between guanine nucleobases separated by one or two A:T base pairs in stilbenedicarboxamide-linked DNA hairpins were obtained by improved kinetic analysis of experimental data. The charge-transfer rates in four different DNA sequences were calculated using a density-functional-based tight-binding model and a semiclassical superexchange model. Site energies and charge-transfer integrals were calculated directly as the diagonal and off-diagonal matrix elements of the Kohn-Sham Hamiltonian, respectively, for all possible combinations of nucleobases. Taking into account the Coulomb interaction between the negative charge on the stilbenedicarboxamide linker and the hole on the DNA strand as well as effects of base pair twisting, the relative order of the experimental rates for hole transfer in different hairpins could be reproduced by tight-binding calculations. To reproduce quantitatively the absolute values of the measured rate constants, the effect of the reorganization energy was taken into account within the semiclassical superexchange model for charge transfer. The experimental rates could be reproduced with reorganization energies near 1 eV. The quantum chemical data obtained were used to discuss charge carrier mobility and hole-transport equilibria in DNA. PMID:16231945

  14. Ultrasound perfusion signal processing for tumor detection

    NASA Astrophysics Data System (ADS)

    Kim, MinWoo; Abbey, Craig K.; Insana, Michael F.

    2016-04-01

    Enhanced blood perfusion in a tissue mass is an indication of neo-vascularity and a sign of a potential malignancy. Ultrasonic pulsed-Doppler imaging is a preferred modality for noninvasive monitoring of blood flow. However, the weak blood echoes and disorganized slow flow make it difficult to detect perfusion using standard methods without the expense and risk of contrast enhancement. Our research measures the efficiency of conventional power-Doppler (PD) methods at discriminating flow states by comparing measurement performance to that of an ideal discriminator. ROC analysis applied to the experimental results shows that power Doppler methods are just 30-50 % efficient at perfusion flows less than 1ml/min, suggesting an opportunity to improve perfusion assessment through signal processing. A new perfusion estimator is proposed by extending the statistical discriminator approach. We show that 2-D perfusion color imaging may be enhanced using this approach.

  15. Absolute/convective instability of planar viscoelastic jets

    NASA Astrophysics Data System (ADS)

    Ray, Prasun K.; Zaki, Tamer A.

    2015-01-01

    Spatiotemporal linear stability analysis is used to investigate the onset of local absolute instability in planar viscoelastic jets. The influence of viscoelasticity in dilute polymer solutions is modeled with the FENE-P constitutive equation which requires the specification of a non-dimensional polymer relaxation time (the Weissenberg number, We), the maximum polymer extensibility, L, and the ratio of solvent and solution viscosities, β. A two-parameter family of velocity profiles is used as the base state with the parameter, S, controlling the amount of co- or counter-flow while N-1 sets the thickness of the jet shear layer. We examine how the variation of these fluid and flow parameters affects the minimum value of S at which the flow becomes locally absolutely unstable. Initially setting the Reynolds number to Re = 500, we find that the first varicose jet-column mode dictates the presence of absolute instability, and increasing the Weissenberg number produces important changes in the nature of the instability. The region of absolute instability shifts towards thin shear layers, and the amount of back-flow needed for absolute instability decreases (i.e., the influence of viscoelasticity is destabilizing). Additionally, when We is sufficiently large and N-1 is sufficiently small, single-stream jets become absolutely unstable. Numerical experiments with approximate equations show that both the polymer and solvent contributions to the stress become destabilizing when the scaled shear rate, η = /W e dU¯1/dx 2L ( /d U ¯ 1 d x 2 is the base-state velocity gradient), is sufficiently large. These qualitative trends are largely unchanged when the Reynolds number is reduced; however, the relative importance of the destabilizing stresses increases tangibly. Consequently, absolute instability is substantially enhanced, and single-stream jets become absolutely unstable over a sizable portion of the parameter space.

  16. Estimating a regional ventilation-perfusion index

    PubMed Central

    Muller, P A; Li, T; Isaacson, D; Newell, J C; Saulnier, G J; Kao, Tzu-Jen; Ashe, Jeffrey

    2015-01-01

    This is a methods paper, where an approximation to the local ventilation-perfusion ratio is derived. This approximation, called the ventilation-perfusion index since it is not exactly the physiological ventilation-perfusion ratio, is calculated using conductivity reconstructions obtained using electrical impedance tomography. Since computation of the ventilation-perfusion index only requires knowledge of the internal conductivity, any conductivity reconstruction method may be used. The method is explained, and results are presented using conductivities obtained from two EIT systems, one using an iterative method and the other a linearization method. PMID:26006279

  17. Intra-procedural Transcatheter Intraarterial Perfusion MRI as a Predictor of Tumor Response to Chemoembolization for Hepatocellular Carcinoma

    PubMed Central

    Wang, Dingxin; Gaba, Ron C.; Jin, Brian; Riaz, Ahsun; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Ragin, Ann B.; Kulik, Laura M.; Mulcahy, Mary F.; Salem, Riad; Larson, Andrew C.; Omary, Reed A.

    2011-01-01

    Rationale and Objectives To prospectively test the hypothesis that transcatheter intraarterial perfusion magnetic resonance imaging (TRIP-MRI) measured semi-quantitative perfusion reductions during transcatheter arterial chemoembolization of hepatocellular carcinoma (HCC) are associated with tumor response. Materials and Methods Twenty eight patients (mean age 63 years; range 47–87 years) with 29 tumors underwent chemoembolization in a combined MR-interventional radiology suite. Intra-procedural tumor perfusion reductions during chemoembolization were monitored using TRIP-MRI. Pre- and post-–chemoembolization semi-quantitative area under the time-signal enhancement curve (AUC) tumor perfusion was measured. Mean tumor perfusion pre- and post-chemoembolization were compared using a paired t-test. Imaging follow-up was performed one to three months after chemoembolization. We studied the relationship between short-term tumor imaging response and intra-procedural perfusion reductions using univariate and multivariate analysis. Results Intra-procedural AUC perfusion value decreased significantly after chemoembolization (342.1 versus 158.6 arbitrary unit, P < 0.001). Twenty six patients with 27 HCCs (n = 27) had follow-up imaging at mean 39 days post-chemoembolization. Favorable response was present in 67% of these treated tumors according to necrosis criteria. 15 of 16 (94%) tumors with 25–75% perfusion reductions showed necrosis treatment response compared to only 3 of 11 (27%) tumors with perfusion reductions outside the above range (P = 0.001). Multivariate logistic regression indicated that intra-procedural tumor perfusion reduction and Child-Pugh class were independent factors associated significantly with tumor response (P = 0.012 and 0.047, respectively). Conclusion TRIP-MRI can successfully measure semi-quantitative changes in HCC perfusion during chemoembolization. Intra-procedural tumor perfusion reductions are associated with future tumor response. PMID

  18. Role of dynamic CT perfusion study in evaluating various intracranial space-occupying lesions

    PubMed Central

    Kamble, Ravindra B; Jayakumar, Peruvumba N; Shivashankar, Ravishankar

    2015-01-01

    Aims: Differentiating intracranial mass lesions on CT scan is challenging. The purpose of our study was to determine the perfusion parameters in various intracranial space-occupying lesions (ICSOL), differentiate benign and malignant lesions, and differentiate between grades of gliomas. Materials and Methods: We performed CT perfusion (CTP) in 64 patients, with age ranging from 17 to 68 years, having space-occupying lesions in brain and calculated relative cerebral blood flow (rCBF) and relative cerebral blood volume (rCBV). Results: We found significantly lower perfusion in low-grade gliomas as compared to high-grade tumors, lymphoma, and metastases. Similarly in infective lesions, TWT and abscesses showed significantly lower perfusion compared to TOT. In ring enhancing lesions, capsule of TWT showed significantly lower perfusion as compared to abscesses, TOT, and metastases. Conclusion: Thus, in conclusion, infective lesions can be differentiated from tumors like lymphomas, high-grade gliomas, or metastases based on perfusion parameters. The cut off value of rCBV 1.64 can be used to differentiate between low grade and high grade gliomas. However, depending only on perfusion parameters, differentiation between the tumors like lymphomas, high-grade gliomas, and metastases may not be possible. PMID:25969639

  19. Arterial Spin Labeling Measurements of Cerebral Perfusion Territories in Experimental Ischemic Stroke

    PubMed Central

    Leoni, Renata F.; Paiva, Fernando F.; Kang, Byeong-Teck; Henning, Erica C.; Nascimento, George C.; Tannús, Alberto; De Araújo, Dráulio B.; Silva, Afonso C.

    2016-01-01

    Collateral circulation, defined as the supplementary vascular network that maintains cerebral blood flow (CBF) when the main vessels fail, constitutes one important defense mechanism of the brain against ischemic stroke. In the present study, continuous arterial spin labeling (CASL) was used to quantify CBF and obtain perfusion territory maps of the major cerebral arteries in spontaneously hypertensive rats (SHR) and their normotensive Wistar-Kyoto (WKY) controls. Results show that both WKY and SHR have complementary, yet significantly asymmetric perfusion territories. Right or left dominances were observed in territories of the anterior (ACA), middle and posterior cerebral arteries, and the thalamic artery. Magnetic resonance angiography showed that some of the asymmetries were correlated with variations of the ACA. The leptomeningeal circulation perfusing the outer layers of the cortex was observed as well. Significant and permanent changes in perfusion territories were obtained after temporary occlusion of the right middle cerebral artery in both SHR and WKY, regardless of their particular dominance. However, animals with right dominance presented a larger volume change of the left perfusion territory (23 ± 9%) than animals with left dominance (7 ± 5%, P < 0.002). The data suggest that animals with contralesional dominance primarily safeguard local CBF values with small changes in contralesional perfusion territory, while animals with ipsilesional dominance show a reversal of dominance and a substantial increase in contralesional perfusion territory. These findings show the usefulness of CASL to probe the collateral circulation. PMID:24323754

  20. Absolute instability of a viscous hollow jet

    NASA Astrophysics Data System (ADS)

    Gañán-Calvo, Alfonso M.

    2007-02-01

    An investigation of the spatiotemporal stability of hollow jets in unbounded coflowing liquids, using a general dispersion relation previously derived, shows them to be absolutely unstable for all physical values of the Reynolds and Weber numbers. The roots of the symmetry breakdown with respect to the liquid jet case, and the validity of asymptotic models are here studied in detail. Asymptotic analyses for low and high Reynolds numbers are provided, showing that old and well-established limiting dispersion relations [J. W. S. Rayleigh, The Theory of Sound (Dover, New York, 1945); S. Chandrasekhar, Hydrodynamic and Hydromagnetic Stability (Dover, New York, 1961)] should be used with caution. In the creeping flow limit, the analysis shows that, if the hollow jet is filled with any finite density and viscosity fluid, a steady jet could be made arbitrarily small (compatible with the continuum hypothesis) if the coflowing liquid moves faster than a critical velocity.

  1. Stitching interferometry: recent results and absolute calibration

    NASA Astrophysics Data System (ADS)

    Bray, Michael

    2004-02-01

    Stitching Interferometry is a method of analysing large optical components using a standard "small" interferometer. This result is obtained by taking multiple overlapping images of the large component, and numerically "stitching" these sub-apertures together. We have already reported the industrial use our Stitching Interferometry systems (Previous SPIE symposia), but experimental results had been lacking because this technique is still new, and users needed to get accustomed to it before producing reliable measurements. We now have more results. We will report user comments and show new, unpublished results. We will discuss sources of error, and show how some of these can be reduced to arbitrarily small values. These will be discussed in some detail. We conclude with a few graphical examples of absolute measurements performed by us.

  2. Laser Doppler imaging of myocardial perfusion during coronary bypass surgery

    NASA Astrophysics Data System (ADS)

    Wardell, Karin; Hermansson, Ulf; Nilsson, Gert E.; Casimir-Ahn, Henrik

    2000-05-01

    Laser Doppler perfusion imaging has been used to assess the myocardium perfusion on the arrested heart during bypass surgery. Twenty-two patients undergoing coronary artery bypass grafting, including usage of the left internal thoracic artery, were included in the study. The anticipated perfusion increase following declamping of the internal thoracic artery was investigated by mapping areas at the size of 10 cm X 11 cm, (n equals 11) and 7 cm X 5 cm (n equals 11). The larger images allowed quantification of blood flow in different regions of the myocardium. The size of the affected area was 32.2 +/- 12.9 cm2 with a total increase of 3.17 +/- 0.75 a.u. (range 0 - 10 a.u.). Corresponding values for areas surrounding the vessels and areas defined as the larger vessels in the myocardium were 29.0 +/- 10.9 cm2 (2.85 +/- 0.57 a.u.) and 3.5 +/- 2.8 cm2 (6.78 +/- 0.18 a.u.). All subjects but two showed a substantial blood flow increase (> 2 a.u.) after release of the clamp. Six subjects had a total increase of at least 4 a.u. Correlation analysis between areas including various number of sites showed an r equals 0.91 (p < 0,0001) or better. In conclusion, laser Doppler perfusion imaging can easily be used intraoperatively in conjunction with bypass surgery. It enables immediate assessment of both the increase and spatial distribution of myocardial perfusion following declamping of an arterial graft.

  3. Lyman alpha SMM/UVSP absolute calibration and geocoronal correction

    NASA Technical Reports Server (NTRS)

    Fontenla, Juan M.; Reichmann, Edwin J.

    1987-01-01

    Lyman alpha observations from the Ultraviolet Spectrometer Polarimeter (UVSP) instrument of the Solar Maximum Mission (SMM) spacecraft were analyzed and provide instrumental calibration details. Specific values of the instrument quantum efficiency, Lyman alpha absolute intensity, and correction for geocoronal absorption are presented.

  4. Cosmology with negative absolute temperatures

    NASA Astrophysics Data System (ADS)

    Vieira, J. P. P.; Byrnes, Christian T.; Lewis, Antony

    2016-08-01

    Negative absolute temperatures (NAT) are an exotic thermodynamical consequence of quantum physics which has been known since the 1950's (having been achieved in the lab on a number of occasions). Recently, the work of Braun et al. [1] has rekindled interest in negative temperatures and hinted at a possibility of using NAT systems in the lab as dark energy analogues. This paper goes one step further, looking into the cosmological consequences of the existence of a NAT component in the Universe. NAT-dominated expanding Universes experience a borderline phantom expansion (w < ‑1) with no Big Rip, and their contracting counterparts are forced to bounce after the energy density becomes sufficiently large. Both scenarios might be used to solve horizon and flatness problems analogously to standard inflation and bouncing cosmologies. We discuss the difficulties in obtaining and ending a NAT-dominated epoch, and possible ways of obtaining density perturbations with an acceptable spectrum.

  5. Technical Pitfalls of Signal Truncation in Perfusion MRI of Glioblastoma

    PubMed Central

    Wong, Kelvin K.; Fung, Steve H.; New, Pamela Z.; Wong, Stephen T. C.

    2016-01-01

    Dynamic susceptibility contrast (DSC) perfusion-weighted imaging (PWI) is widely used in clinical settings for the radiological diagnosis of brain tumor. The signal change in brain tissue in gradient echo-based DSC PWI is much higher than in spin echo-based DSC PWI. Due to its exquisite sensitivity, gradient echo-based sequence is the preferred method for imaging of all tumors except those near the base of the skull. However, high sensitivity also comes with a dynamic range problem. It is not unusual for blood volume to increase in gene-mediated cytotoxic immunotherapy-treated glioblastoma patients. The increase of fractional blood volume sometimes saturates the MRI signal during first-pass contrast bolus arrival and presents signal truncation artifacts of various degrees in the tumor when a significant amount of blood exists in the image pixels. It presents a hidden challenge in PWI, as this signal floor can be either close to noise level or just above and can go no lower. This signal truncation in the signal intensity time course is a significant issue that deserves attention in DSC PWI. In this paper, we demonstrate that relative cerebral blood volume and relative cerebral blood flow (rCBF) are underestimated due to signal truncation in DSC perfusion, in glioblastoma patients. We propose the use of second-pass tissue residue function in rCBF calculation using least-absolute-deviation deconvolution to avoid the underestimation problem. PMID:27531989

  6. Technical Pitfalls of Signal Truncation in Perfusion MRI of Glioblastoma.

    PubMed

    Wong, Kelvin K; Fung, Steve H; New, Pamela Z; Wong, Stephen T C

    2016-01-01

    Dynamic susceptibility contrast (DSC) perfusion-weighted imaging (PWI) is widely used in clinical settings for the radiological diagnosis of brain tumor. The signal change in brain tissue in gradient echo-based DSC PWI is much higher than in spin echo-based DSC PWI. Due to its exquisite sensitivity, gradient echo-based sequence is the preferred method for imaging of all tumors except those near the base of the skull. However, high sensitivity also comes with a dynamic range problem. It is not unusual for blood volume to increase in gene-mediated cytotoxic immunotherapy-treated glioblastoma patients. The increase of fractional blood volume sometimes saturates the MRI signal during first-pass contrast bolus arrival and presents signal truncation artifacts of various degrees in the tumor when a significant amount of blood exists in the image pixels. It presents a hidden challenge in PWI, as this signal floor can be either close to noise level or just above and can go no lower. This signal truncation in the signal intensity time course is a significant issue that deserves attention in DSC PWI. In this paper, we demonstrate that relative cerebral blood volume and relative cerebral blood flow (rCBF) are underestimated due to signal truncation in DSC perfusion, in glioblastoma patients. We propose the use of second-pass tissue residue function in rCBF calculation using least-absolute-deviation deconvolution to avoid the underestimation problem. PMID:27531989

  7. Absolute photon-flux measurements in the vacuum ultraviolet

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.; Haddad, G. N.

    1974-01-01

    Absolute photon-flux measurements in the vacuum ultraviolet have extended to short wavelengths by use of rare-gas ionization chambers. The technique involves the measurement of the ion current as a function of the gas pressure in the ion chamber. The true value of the ion current, and hence the absolute photon flux, is obtained by extrapolating the ion current to zero gas pressure. Examples are given at 162 and 266 A. The short-wavelength limit is determined only by the sensitivity of the current-measuring apparatus and by present knowledge of the photoionization processes that occur in the rate gases.

  8. Long term perfusion system supporting adipogenesis

    PubMed Central

    Abbott, Rosalyn D.; Raja, Waseem K.; Wang, Rebecca Y.; Stinson, Jordan A.; Glettig, Dean L.; Burke, Kelly A.; Kaplan, David L.

    2015-01-01

    Adipose tissue engineered models are needed to enhance our understanding of disease mechanisms and for soft tissue regenerative strategies. Perfusion systems generate more physiologically relevant and sustainable adipose tissue models, however adipocytes have unique properties that make culturing them in a perfusion environment challenging. In this paper we describe the methods involved in the development of two perfusion culture systems (2D and 3D) to test their applicability for long term in vitro adipogenic cultures. It was hypothesized that a silk protein biomaterial scaffold would provide a 3D framework, in combination with perfusion flow, to generate a more physiologically relevant sustainable adipose tissue engineered model than 2D cell culture. Consistent with other studies evaluating 2D and 3D culture systems for adipogenesis we found that both systems successfully model adipogensis, however 3D culture systems were more robust, providing the mechanical structure required to contain the large, fragile adipocytes that were lost in 2D perfused culture systems. 3D perfusion also stimulated greater lipogenesis and lipolysis and resulted in decreased secretion of LDH compared to 2D perfusion. Regardless of culture configuration (2D or 3D) greater glycerol was secreted with the increased nutritional supply provided by perfusion of fresh media. These results are promising for adipose tissue engineering applications including long term cultures for studying disease mechanisms and regenerative approaches, where both acute (days to weeks) and chronic (weeks to months) cultivation are critical for useful insight. PMID:25843606

  9. Myocardial perfusion with rubidium-82. III. Theory relating severity of coronary stenosis to perfusion deficit

    SciTech Connect

    Mullani, N.A.

    1984-11-01

    The relation between the quantitative perfusion deficit, as measured by emission computerized tomography, and the severity of coronary artery stenosis is important for the noninvasive clinical evaluation of coronary artery disease in man. Positron emission tomography allows direct noninvasive measurement of myocardial perfusion and quantification of the size of the perfusion defect. Given this important imformation, a mathematical model has been derived to gauge the severity of a coronary stenosis from quantitative perfusion measurements in the normal and poststenotic regions of the heart. The theoretical basis is presented for relating regional myocardial perfusion and regional perfusion resistance to total, coronary blood flow and resistance at normal resting flow and during maximal coronary vasodilation. The concept of perfusion reserve is presented as a clinical measure of the severity of a stenosis.

  10. Effects of some anesthetic agents on skin microcirculation evaluated by laser Doppler perfusion imaging in mice

    PubMed Central

    2013-01-01

    Background Anesthetic agents alter microcirculation, influencing tissue oxygenation and delivery of vital substrates. Laser Doppler perfusion imaging is a widespread technique in the field of microvascular research that can evaluate noninvasively and in real time the effects of environmental conditions, physical manipulations, diseases and treatments on peripheral perfusion. This study aims to evaluate laser Doppler perfusion imaging as a means to detect changes in skin microcirculation induced by some popular anesthetic agents in a murine model. Twenty-four age- and gender-matched healthy CD1 mice were examined by laser Doppler perfusion imaging. The skin microcirculatory response was measured at the level of plantar surfaces during isoflurane anesthesia with or without subsequent dexmedetomidine or acepromazine. At the end of the procedure, dexmedetomidine was reversed by atipamezole administration. Results In all mice, skin blood flow under isoflurane anesthesia did not show significant differences over time (P = 0.1). The serial perfusion pattern and values following acepromazine or dexmedetomidine administration differed significantly (P < 0.05). Conclusions We standardized a reliable laser Doppler perfusion imaging protocol to non-invasively assess changes in skin microcirculation induced by anesthesia in mice, considering the advantages and drawbacks of this technique and its translational value. PMID:24341447

  11. Cardiac PET Perfusion: Prognosis, Risk Stratification, Clinical Management

    PubMed Central

    Dorbala, Sharmila; Di Carli, Marcelo F.

    2014-01-01

    Myocardial perfusion imaging (MPI) with positron emission tomography (PET) has expanded significantly over the past decade. With the wider availability of PET scanners and the routine use of quantitative blood flow imaging, the clinical use of PET MPI is expected to increase further. PET MPI is a powerful tool to identify risk, to quantify risk, and to guide therapy in patients with known or suspected coronary artery disease (CAD). A large body of evidence supports the prognostic value of PET MPI and ejection fraction in intermediate to high risk subjects, in women, in obese individuals and in post coronary artery bypass grafting (CABG) individuals. A normal perfusion study indicates low risk (< 1% annualized rate of cardiac events of cardiac death and non-fatal myocardial infarction), while an abnormal study indicates high risk. With accurate risk stratification, high quality images, and quantitation PET MPI may transform the management of patients with known or suspected CAD. PMID:25234079

  12. Quantitative 4D Transcatheter Intraarterial Perfusion MR Imaging as a Method to Standardize Angiographic Chemoembolization Endpoints

    PubMed Central

    Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.

    2011-01-01

    PURPOSE We aimed to test the hypothesis that subjective angiographic endpoints during transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) exhibit consistency and correlate with objective intraprocedural reductions in tumor perfusion as determined by quantitative four dimensional (4D) transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging. MATERIALS AND METHODS This prospective study was approved by the institutional review board. Eighteen consecutive patients underwent TACE in a combined MR/interventional radiology (MR-IR) suite. Three board-certified interventional radiologists independently graded the angiographic endpoint of each procedure based on a previously described subjective angiographic chemoembolization endpoint (SACE) scale. A consensus SACE rating was established for each patient. Patients underwent quantitative 4D TRIP-MR imaging immediately before and after TACE, from which mean whole tumor perfusion (Fρ) was calculated. Consistency of SACE ratings between observers was evaluated using the intraclass correlation coefficient (ICC). The relationship between SACE ratings and intraprocedural TRIP-MR imaging perfusion changes was evaluated using Spearman’s rank correlation coefficient. RESULTS The SACE rating scale demonstrated very good consistency among all observers (ICC = 0.80). The consensus SACE rating was significantly correlated with both absolute (r = 0.54, P = 0.022) and percent (r = 0.85, P < 0.001) intraprocedural perfusion reduction. CONCLUSION The SACE rating scale demonstrates very good consistency between raters, and significantly correlates with objectively measured intraprocedural perfusion reductions during TACE. These results support the use of the SACE scale as a standardized alternative method to quantitative 4D TRIP-MR imaging to classify patients based on embolic endpoints of TACE. PMID:22021520

  13. Quantification of brain perfusion with tracers retained by the brain

    SciTech Connect

    Pupi, A.; Bacciottini, L.; De Cristofaro, M.T.R.; Formiconi, A.R.; Castagnoli, A.

    1991-12-31

    Almost a decade ago, tracers, labelled with {sup 123}I and {sup 99m}Tc, that are retained by the brain, started to be used for studies of regional brain perfusion (regional cerebral blood flow, rCBF). To date, these tracers have been used for brain perfusion imaging with SPECT in brain disorders as well as for physiological activation protocols. Only seldom, however, have they been used in protocols that quantitatively measure rCBF. Nevertheless, comparative studies with perfusion reference tracers have repeatedly demonstrated that the brain uptake of these brain-retained tracers is correlated to perfusion, the major determinant of the distribution of these tracers in the brain. The brain kinetics of {sup 99m}Tc HMPAO, which is the tracer most commonly used, was described with a two-compartment tissue model. The theoretical approach, which is, in itself, sufficient for modeling quantitative measurements with {sup 99m}Tc HMPAO, initially suggested the possibility of empirically narrowing the distance between the brain`s regional uptake of the tracer and rCBF with a linearization algorithm which uses the cerebellum as the reference region. The value of this empirical method is hampered by the fact that the cerebellum can be involved in cerebrovascular disease (i.e. cerebellar diaschisis) as well as in several other brain disorders (e.g. anxiety, and dementia of the Alzheimer type). It also was proposed that different reference regions (occipital, whole slice, or whole brain) should be selected in relation to the brain disorder under study. However, this approach does not solve the main problem because it does not equip us with a reliable tool to evaluate rCBF with a high predictive value, and, at the same time, to reduce intersubject variability. The solution would be to measure a quantitative parameter which directly reflects rCBF, such as the unidirectional influx constant of the freely diffusible flow-limited tracers. 45 refs., 3 figs., 1 tab.

  14. Improving HST Pointing & Absolute Astrometry

    NASA Astrophysics Data System (ADS)

    Lallo, Matthew; Nelan, E.; Kimmer, E.; Cox, C.; Casertano, S.

    2007-05-01

    Accurate absolute astrometry is becoming increasingly important in an era of multi-mission archives and virtual observatories. Hubble Space Telescope's (HST's) Guidestar Catalog II (GSC2) has reduced coordinate error to around 0.25 arcsecond, a factor 2 or more compared with GSC1. With this reduced catalog error, special attention must be given to calibrate and maintain the Fine Guidance Sensors (FGSs) and Science Instruments (SIs) alignments in HST to a level well below this in order to ensure that the accuracy of science product's astrometry keywords and target positioning are limited only by the catalog errors. After HST Servicing Mission 4, such calibrations' improvement in "blind" pointing accuracy will allow for more efficient COS acquisitions. Multiple SIs and FGSs each have their own footprints in the spatially shared HST focal plane. It is the small changes over time in primarily the whole-body positions & orientations of these instruments & guiders relative to one another that is addressed by this work. We describe the HST Cycle 15 program CAL/OTA 11021 which, along with future variants of it, determines and maintains positions and orientations of the SIs and FGSs to better than 50 milli- arcseconds and 0.04 to 0.004 degrees of roll, putting errors associated with the alignment sufficiently below GSC2 errors. We present recent alignment results and assess their errors, illustrate trends, and describe where and how the observer sees benefit from these calibrations when using HST.

  15. Absolute oral bioavailability of ciprofloxacin.

    PubMed

    Drusano, G L; Standiford, H C; Plaisance, K; Forrest, A; Leslie, J; Caldwell, J

    1986-09-01

    We evaluated the absolute bioavailability of ciprofloxacin, a new quinoline carboxylic acid, in 12 healthy male volunteers. Doses of 200 mg were given to each of the volunteers in a randomized, crossover manner 1 week apart orally and as a 10-min intravenous infusion. Half-lives (mean +/- standard deviation) for the intravenous and oral administration arms were 4.2 +/- 0.77 and 4.11 +/- 0.74 h, respectively. The serum clearance rate averaged 28.5 +/- 4.7 liters/h per 1.73 m2 for the intravenous administration arm. The renal clearance rate accounted for approximately 60% of the corresponding serum clearance rate and was 16.9 +/- 3.0 liters/h per 1.73 m2 for the intravenous arm and 17.0 +/- 2.86 liters/h per 1.73 m2 for the oral administration arm. Absorption was rapid, with peak concentrations in serum occurring at 0.71 +/- 0.15 h. Bioavailability, defined as the ratio of the area under the curve from 0 h to infinity for the oral to the intravenous dose, was 69 +/- 7%. We conclude that ciprofloxacin is rapidly absorbed and reliably bioavailable in these healthy volunteers. Further studies with ciprofloxacin should be undertaken in target patient populations under actual clinical circumstances. PMID:3777908

  16. Absolute Instability in Coupled-Cavity TWTs

    NASA Astrophysics Data System (ADS)

    Hung, D. M. H.; Rittersdorf, I. M.; Zhang, Peng; Lau, Y. Y.; Simon, D. H.; Gilgenbach, R. M.; Chernin, D.; Antonsen, T. M., Jr.

    2014-10-01

    This paper will present results of our analysis of absolute instability in a coupled-cavity traveling wave tube (TWT). The structure mode at the lower and upper band edges are respectively approximated by a hyperbola in the (omega, k) plane. When the Briggs-Bers criterion is applied, a threshold current for onset of absolute instability is observed at the upper band edge, but not the lower band edge. The nonexistence of absolute instability at the lower band edge is mathematically similar to the nonexistence of absolute instability that we recently demonstrated for a dielectric TWT. The existence of absolute instability at the upper band edge is mathematically similar to the existence of absolute instability in a gyroton traveling wave amplifier. These interesting observations will be discussed, and the practical implications will be explored. This work was supported by AFOSR, ONR, and L-3 Communications Electron Devices.

  17. Validation of GOCE by absolute and relative gravimetry

    NASA Astrophysics Data System (ADS)

    Pettersen, B. R.; Sprlak, M.; Lysaker, D. I.; Omang, O. C. D.; Sekowski, M.; Dykowski, P.

    2012-04-01

    Absolute gravimetry has been performed in 2011 by FG5 and A10 instruments in selected sites of the Norwegian first order gravity network. These observations are used as reference values to transform a large number of relative gravity values collected in 1968-1972. The outcome is a database at current epoch in a reference frame defined by the absolute gravity values. This constitutes our test field for validation of GOCE results. In the test fields, validation of GOCE-derived gravity anomalies was performed. The spectral enhancement method was applied to avoid the spectral inconsistency between the terrestrial and the satellite data. For this purpose, contributions of the EGM2008 model and a gravitational effect of a residual terrain model were calculated.

  18. Absolute negative mobility of interacting Brownian particles

    NASA Astrophysics Data System (ADS)

    Ou, Ya-li; Hu, Cai-tian; Wu, Jian-chun; Ai, Bao-quan

    2015-12-01

    Transport of interacting Brownian particles in a periodic potential is investigated in the presence of an ac force and a dc force. From Brownian dynamic simulations, we find that both the interaction between particles and the thermal fluctuations play key roles in the absolute negative mobility (the particle noisily moves backwards against a small constant bias). When no the interaction acts, there is only one region where the absolute negative mobility occurs. In the presence of the interaction, the absolute negative mobility may appear in multiple regions. The weak interaction can be helpful for the absolute negative mobility, while the strong interaction has a destructive impact on it.

  19. Diurnal Curve of the Ocular Perfusion Pressure

    PubMed Central

    Moreira, TCA; Bezerra, BSP; Vianello, MP; Corradi, J; Dorairaj, SK; Prata, TS

    2016-01-01

    ABSTRACT Purpose: To describe the diurnal variation of the ocular perfusion pressure (OPP) in normal, suspects and glaucoma patients. Materials and methods: Seventy-nine subjects were enrolled in a prospective study. The diurnal curve of intraocular pressure (IOP) was performed and blood pressure measurements were obtained. Each participant was grouped into one of the following based upon the clinical evaluation of the optic disk, IOP and standard achromatic perimetry (SAP): 18 eyes were classified as normal (normal SAP, normal optic disk evaluation and IOP < 21 mm Hg in two different measurements), 30 eyes as glaucoma suspect (GS) (normal SAP and mean deviation (MD), C/D ration > 0.5 or asymmetry > 0.2 and/or ocular hypertension), 31 eyes as early glaucoma (MD < -6 dB, glaucomatous optic neuropathy and SAP and MDs on SAP. Standard achromatic perimetry was performed with the Octopus 3.1.1 Dynamic 24-2 program. Intraocular pressure and blood pressure measurements were taken at 6 am, 9 am, 12, 3 and 6 pm. The patients stayed in the seated position for 5 minutes prior to blood pressure measurements. Results: The mean IOP values in all groups did not follow any regular pattern. The peak IOP was found to be greater in suspect [18.70 ± 3.31 (mm Hg ± SD)] and glaucoma (18.77 ± 4.30 mm Hg) patients as compared to normal subjects (16.11 ± 2.27 mm Hg). In studying the diurnal variation of the OPP, we found lower values at 3 pm in normals (34.21 ± 2.07 mm Hg), at 9 am in suspects (54.35 ± 3.32 mm Hg) and at 12 pm in glaucoma patients (34.84 ± 1.44 mm Hg). Conclusion: Each group has a specific OPP variation during the day with the most homogeneous group being the suspect one. It is important to keep studying the IOP and OPP variation for increased comprehension of the pathophysiology of glaucomatous optic neuropathy. How to cite this article: Kanadani FN, Moreira TCA, Bezerra BSP, Vianello MP, Corradi J, Dorairaj SK, Prata TS. Diurnal Curve of the Ocular Perfusion

  20. TISSUE ENGINEERING PERFUSABLE CANCER MODELS

    PubMed Central

    Fong, E.L.; Santoro, M.; Farach-Carson, M.C.; Kasper, F.K.; Mikos, A.G.

    2014-01-01

    The effect of fluid flow on cancer progression is currently not well understood, highlighting the need for perfused tumor models to close this gap in knowledge. Enabling biological processes at the cellular level to be modeled with high spatiotemporal control, microfluidic tumor models have demonstrated applicability as platforms to study cell-cell interactions, effect of interstitial flow on tumor migration and the role of vascular barrier function. To account for the multi-scale nature of cancer growth and invasion, macroscale models are also necessary. The consideration of fluid dynamics within tumor models at both the micro- and macroscopic levels may greatly improve our ability to more fully mimic the tumor microenvironment. PMID:24634812

  1. Mathematical Model for Absolute Magnetic Measuring Systems in Industrial Applications

    NASA Astrophysics Data System (ADS)

    Fügenschuh, Armin; Fügenschuh, Marzena; Ludszuweit, Marina; Mojsic, Aleksandar; Sokół, Joanna

    2015-09-01

    Scales for measuring systems are either based on incremental or absolute measuring methods. Incremental scales need to initialize a measurement cycle at a reference point. From there, the position is computed by counting increments of a periodic graduation. Absolute methods do not need reference points, since the position can be read directly from the scale. The positions on the complete scales are encoded using two incremental tracks with different graduation. We present a new method for absolute measuring using only one track for position encoding up to micrometre range. Instead of the common perpendicular magnetic areas, we use a pattern of trapezoidal magnetic areas, to store more complex information. For positioning, we use the magnetic field where every position is characterized by a set of values measured by a hall sensor array. We implement a method for reconstruction of absolute positions from the set of unique measured values. We compare two patterns with respect to uniqueness, accuracy, stability and robustness of positioning. We discuss how stability and robustness are influenced by different errors during the measurement in real applications and how those errors can be compensated.

  2. Pattern of brain blood perfusion in tinnitus patients using technetium-99m SPECT imaging

    PubMed Central

    Mahmoudian, Saeid; Farhadi, Mohammad; Gholami, Saeid; Saddadi, Fariba; Karimian, Ali Reza; Mirzaei, Mohammad; Ghoreyshi, Esmaeel; Ahmadizadeh, Majid; Lenarz, Thomas

    2012-01-01

    Background and Purpose: Tinnitus is associated with an increased activity in central auditory system as demonstrated by neuroimaging studies. Brain perfusion scanning using single photon emission computed tomography (SPECT) was done to understand the pattern of brain blood perfusion of tinnitus subjects and find the areas which are mostly abnormal in these patients. Materials and Methods: A number of 122 patients with tinnitus were enrolled to this cross-sectional study. They underwent SPECT and magnetic resonance imaging (MRI) of brain, and the images were fused to find the regions with abnormal perfusion. Results: SPECT scan results were abnormal in 101 patients (83%). Most patients had bilateral abnormal perfusion (N = 65, 53.3%), and most subjects had abnormality in middle-temporal gyrus (N = 83, 68%) and temporoparietal cortex (N = 46, 37.7%). Patients with multifocal involvement had the least mean age than other 2 groups (patients with no abnormality and unifocal abnormality) (P value = 0.045). Conclusions: Brain blood perfusion pattern differs in patient with tinnitus than others. These patients have brain perfusion abnormality, mostly in auditory gyrus (middle temporal) and associative cortex (temporoparietal cortex). Multifocal abnormalities might be due to more cognitive and emotional brain centers involvement due to tinnitus or more stress and anxiety of tinnitus in the young patients. PMID:23267375

  3. Blue Laser Light Increases Perfusion of a Skin Flap Via Release of Nitric Oxide from Hemoglobin

    PubMed Central

    Mittermayr, Rainer; Osipov, Anatoly; Piskernik, Christina; Haindl, Susanne; Dungel, Peter; Weber, Carina; Vladimirov, Yuri A; Redl, Heinz; Kozlov, Andrey V

    2007-01-01

    It has recently been shown that nitrosyl complexes of hemoglobin (NO-Hb) are sensitive to low-level blue laser irradiation, suggesting that laser irradiation can facilitate the release of biologically active nitric oxide (NO), which can affect tissue perfusion. The aim of this study was to evaluate the therapeutic value of blue laser irradiation for local tissue perfusion after surgical intervention. Blood was withdrawn from a rat, exposed to NO and infused back to the same rat or used for in vitro experiments. In vitro, an increase of NO-Hb levels (electron paramagnetic resonance spectroscopy) up to 15 μM in rat blood did not result in the release of detectable amounts of NO (NO selective electrode). Blue laser irradiation of NO-Hb in blood caused decomposition of NO-Hb complexes and release of free NO. Systemic infusion of NO-Hb in rats affected neither systemic circulation (mean arterial pressure) nor local tissue perfusion (Doppler blood flow imaging system). In contrast, a clear enhancement of local tissue perfusion was observed in epigastric flap when elevated NO-Hb levels in blood were combined with local He-Cd laser irradiation focused on the left epigastric artery. The enhancement of regional tissue perfusion was not accompanied by any detectable changes in systemic circulation. This study demonstrates that blue laser irradiation improves local tissue perfusion in a controlled manner stimulating NO release from NO-Hb complexes. PMID:17515954

  4. Ventilation-perfusion imaging in pulmonary papillomatosis

    SciTech Connect

    Espinola, D.; Rupani, H.; Camargo, E.E.; Wagner, H.N. Jr.

    1981-11-01

    Three children with laryngeal papillomas involving the lungs had serial ventilation-perfusion scintigrams to assess results of therapy designed to reduce the bronchial involvement. Different imaging patterns were observed depending on size, number, and location of lesions. In early parenchymal involvement a ventilation-perfusion mismatch was seen. The initial and follow-up studies correlated well with clinical and radiographic findings. This noninvasive procedure is helpful in evaluating ventilatory and perfusion impairment in these patients as well as their response to treatment.

  5. Cochlear perfusion with a viscous fluid.

    PubMed

    Wang, Yi; Olson, Elizabeth S

    2016-07-01

    The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawn from basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner's membrane (RM), while in cochleae perfused with 0.125% and 0.25% HA RM was torn. Thus, the CAP threshold elevation was likely due to the broken RM, likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed, perhaps due to the presence and

  6. Effect of graded hypoxia on retention of technetium-99m-nitroheterocycle in perfused rat heart

    SciTech Connect

    Rumsey, W.L.; Patel, B.; Linder, K.E.

    1995-04-01

    The purpose of this investigation was to determine the effects of graded hypoxia on the retention of a {sup 99m}Tc-labeled nitroimidazole. Rat hearts were perfused retrogradely with Krebs-Henseleit buffer at 37{degrees}C and paced at 5 Hz. After a 20-min stabilization period, coronary flow was maintained at 8 ml/min/g wet wt and the hearts were perfused with media equilibrated with gas mixtures containing 5% CO{sub 2} and various levels of O{sub 2}, from 544 to 29 Torr. Technetium-99m-O(PnAO-1-(2-nitroimidazole)), BMS-181321, was infused for 20 min into a side port of the aortic cannula. Perfusion continued for an additional 40 min to allow for compound clearance. Each decrease of perfusate PO{sub 2} brought about an increase in the retention of BMS-181321, resulting in a good correlation between its retention and perfusate PO{sub 2} (r=0.97). Myocardial oxygen consumption was independent of oxygen delivery when the perfusate oxygen pressure was greater than 350 Torr. Below this value, oxygen consumption declined markedly as influent PO{sub 2}. A good correlation was obtained between retention of the nitroheterocycle and the cytosolic lactate/pyruvate ratio (r=0.98). When glucose was omitted from the perfusate (PO{sub 2}=27 Torr), retention of the nitroheterocycle was increased by about 25% as compared to hearts perfused in the presence of this substrate. These results indicate that myocardial retention of BMS-181321 is coupled to the level of tissue oxygenation and that hypoxic retention may be affected by substrate input. 24 refs., 3 figs., 1 tab.

  7. Inhomogeneity of pulmonary perfusion during sustained microgravity on SLS-1.

    PubMed

    Prisk, G K; Guy, H J; Elliott, A R; West, J B

    1994-04-01

    We studied the effects of gravity on the inhomogeneity of pulmonary perfusion in humans by performing hyperventilation-breath-hold single-breath measurements before, during, and after 9 days of continuous exposure to microgravity during the Spacelab Life Sciences-1 (SLS-1) mission. In microgravity the indicators of inhomogeneity of perfusion, especially the size of cardiogenic oscillations in expired CO2 and the height of phase IV, were markedly reduced. Cardiogenic oscillations were reduced to approximately 60% of their preflight standing size, and the height of phase IV was between 0 and -8% (a terminal fall became a small terminal rise) of the preflight standing value. The terminal change in expired CO2 was nearly abolished in microgravity, indicating more uniformity of blood flow between lung units that close and those that remain open at the end of expiration. A possible explanation of this observation is the disappearance of gravity-dependent topographic inequality of blood flow. The residual cardiogenic oscillations in expired CO2 imply a persisting inhomogeneity of perfusion in the absence of gravity, probably in lung regions that are not within the same acinus. PMID:8045853

  8. Inhomogeneity of pulmonary perfusion during sustained microgravity on SLS-1

    NASA Technical Reports Server (NTRS)

    Prisk, G. Kim; Guy, Harold J. B.; Elliott, Ann R.; West, John B.

    1994-01-01

    We studied the effects of gravity on the inhomogeneity of pulmonary perfusion in humans by performing hyperventilation-breath-hold single-breath measurements before, during, and after 9 days of continuous exposure to microgravity during the Spacelab Life Sciences-1 (SLS-1) mission. In microgravity the indicators of inhomogeneity of perfusion, especially the size of cardiogenic oscillations in expired CO2 and the height of phase IV, were markedly reduced. Cardiogenic oscillations were reduced to approximately 60% of their preflight standing size, and the height of phase IV was between 0 and -8% (a terminal fall became a small terminal rise) of the preflight standing value. The terminal change in expired CO2 was nearly abolished in microgravity, indicating more uniformity of blood flow between lung units that close and those that remain open at the end of expiration. A possible explanation of this observation is the disappearance of gravity-dependent topographic inequality of blood flow. The residual cardiogenic oscillations in expired CO2 imply a persisting inhomogeneity of perfusion in the absence of gravity, probably in lung regions that are not within the same acinus.

  9. MR mapping of temperature and perfusion for hyperthermia therapy

    NASA Astrophysics Data System (ADS)

    Wlodarczyk, Waldemar; Vlad, Julia; Lange, Thomas; Wust, Peter; Felix, Roland

    2001-05-01

    The promising results, recently obtained in phantom experiments employing the MR-based proton resonance frequency (PRF) method as a non-invasive tool for the temperature monitoring of hyperthermia therapy, are not easily reproduced in vivo. One of the reasons is the impact of perfusion changes on the PRF-measured temperature. In our experiments in vivo, heat was supplied on one side of the volunteers knee or pelvis by a rubber hose with circulating warm water (50iC). The PRF method was calibrated by the constant temperature sensitivity of pure water of 0.011 ppm/iC. MR mapping of perfusion changes was based on T2*-weighted tracking of the first-pass kinetics of contrast agent. The hemodynamic parameters of regional blood volume (rBV) and mean transit time (MTT) were extracted by fitting pixel-by-pixel the first- pass kinetics to the gamma-variate model. Special attention was directed to improve a quality of the automatic non-linear fit at low signal-to-noise values. The distributions of PRF- based temperature changes show large areas of apparently high temperature elevations (exceeding 10iC) in regions close to the heat source, and others with just as large temperature decays in more distant regions. Areas of apparently high temperature elevations correlate with areas of blood flow increase and vice versa. In conclusion, the visible heat- induced PRF changes in vivo are primarily perfusion changes, which mask the much smaller true temperature changes.

  10. Direct comparisons between absolute and relative geomagnetic paleointensities: Absolute calibration of a relative paleointensity stack

    NASA Astrophysics Data System (ADS)

    Mochizuki, N.; Yamamoto, Y.; Hatakeyama, T.; Shibuya, H.

    2013-12-01

    Absolute geomagnetic paleointensities (APIs) have been estimated from igneous rocks, while relative paleomagnetic intensities (RPIs) have been reported from sediment cores. These two datasets have been treated separately, as correlations between APIs and RPIs are difficult on account of age uncertainties. High-resolution RPI stacks have been constructed from globally distributed sediment cores with high sedimentation rates. Previous studies often assumed that the RPI stacks have a linear relationship with geomagnetic axial dipole moments, and calibrated the RPI values to API values. However, the assumption of a linear relationship between APIs and RPIs has not been evaluated. Also, a quantitative calibration method for the RPI is lacking. We present a procedure for directly comparing API and RPI stacks, thus allowing reliable calibrations of RPIs. Direct comparisons between APIs and RPIs were conducted with virtually no associated age errors using both tephrochronologic correlations and RPI minima. Using the stratigraphic positions of tephra layers in oxygen isotope stratigraphic records, we directly compared the RPIs and APIs reported from welded tuffs contemporaneously extruded with the tephra layers. In addition, RPI minima during geomagnetic reversals and excursions were compared with APIs corresponding to the reversals and excursions. The comparison of APIs and RPIs at these exact points allowed a reliable calibration of the RPI values. We applied this direct comparison procedure to the global RPI stack PISO-1500. For six independent calibration points, virtual axial dipole moments (VADMs) from the corresponding APIs and RPIs of the PISO-1500 stack showed a near-linear relationship. On the basis of the linear relationship, RPIs of the stack were successfully calibrated to the VADMs. The direct comparison procedure provides an absolute calibration method that will contribute to the recovery of temporal variations and distributions of geomagnetic axial dipole

  11. Absolute optical metrology : nanometers to kilometers

    NASA Technical Reports Server (NTRS)

    Dubovitsky, Serge; Lay, O. P.; Peters, R. D.; Liebe, C. C.

    2005-01-01

    We provide and overview of the developments in the field of high-accuracy absolute optical metrology with emphasis on space-based applications. Specific work on the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor is described along with novel applications of the sensor.

  12. Monolithically integrated absolute frequency comb laser system

    DOEpatents

    Wanke, Michael C.

    2016-07-12

    Rather than down-convert optical frequencies, a QCL laser system directly generates a THz frequency comb in a compact monolithically integrated chip that can be locked to an absolute frequency without the need of a frequency-comb synthesizer. The monolithic, absolute frequency comb can provide a THz frequency reference and tool for high-resolution broad band spectroscopy.

  13. Introducing the Mean Absolute Deviation "Effect" Size

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  14. Sublingual microvascular perfusion is altered during normobaric and hyperbaric hyperoxia.

    PubMed

    Milstein, Dan M J; Helmers, Renée; Hackmann, Sanne; Belterman, Charly N W; van Hulst, Robert A; de Lange, Jan

    2016-05-01

    Hyperoxia and hyperbaric oxygen therapy can restore oxygen tensions in tissues distressed by ischemic injury and poor vascularization and is believed to also yield angiogenesis and regulate tissue perfusion. The aim of this study was to develop a model in which hyperoxia-driven microvascular changes could be quantified and to test the hypothesis that microcirculatory responses to both normobaric (NB) and hyperbaric (HB) hyperoxic maneuvers are reversible. Sublingual mucosa microcirculation vessel density, proportion of perfused vessels, vessel diameters, microvascular flow index, macrohemodynamic, and blood gas parameters were examined in male rabbits breathing sequential O2/air mixtures of 21%, 55%, 100%, and return to 21% during NB (1.0bar) and HB (2.5bar) conditions. The results indicate that NB hyperoxia (55% and 100%) produced significant decreases in microvascular density and vascular diameters (p<0.01 and p<0.05, respectively) accompanied by significant increases in systolic and mean arterial blood pressure (p<0.05, respectively) with no changes in blood flow indices when compared to NB normoxia. HB normoxia/hyperoxia resulted in significant decreases in microvascular density (p<0.05), a transient rise in systolic blood pressure at 55% (p<0.01), and no changes in blood vessel diameter and blood flow indices when compared to NB hyperoxia. All microcirculation parameters reverted back to normal values upon return to NB normoxia. We conclude that NB/HB hyperoxia-driven changes elicit reversible physiological control of sublingual mucosa blood perfusion in the presence of steady cardiovascular function and that the absence of microvascular vasoconstriction during HB conditions suggests a beneficial mechanism associated with maintaining peak tissue perfusion states. PMID:26851620

  15. Luminal distension as a possible consequence of experimental intestinal perfusion

    PubMed Central

    Wingate, David; Hyams, Ashley; Phillips, Sidney

    1974-01-01

    In an experimental jejunal perfusion study, distress in healthy subjects occurred during eight out of 16 perfusions in which intestinal secretion was provoked. Calculation demonstrates the volumetric consequences of inadequate recovery of secretory perfusates, and analysis of the perfusion studies shows that distress was significantly associated with poor recovery of the perfusate. These observations are pertinent to increasing interest in the phenomenon of intestinal fluid secretion. PMID:4435588

  16. Perfusion education and training in Europe.

    PubMed

    Merkle, Frank

    2006-01-01

    Perfusion education and training varies considerably throughout Europe. Unlike in the US, where a common curriculum for perfusion education has been established, each European country has its own education system. This fact is further complicated by a multitude of national languages and cultures. Thus, perfusion education programmes vary, not only in content, but also in their academic levels. This article aims to give a comprehensive overview of the situation in each of the 20 member states of the European Board of Cardiovascular Perfusion (EBCP). The EBCP delegates were polled for a description of the process of training and education of clinical perfusionists in their respective countries. Following the initial delegate poll in 2001, an update of the material was performed in spring 2005. In summary, training of clinical perfusionists in Europe varies considerably between countries. A professional body is necessary to oversee the training process and to guarantee a minimum level of clinical competency for cardiovascular perfusionists. PMID:16485693

  17. Absolute Gravity Datum in the Age of Cold Atom Gravimeters

    NASA Astrophysics Data System (ADS)

    Childers, V. A.; Eckl, M. C.

    2014-12-01

    The international gravity datum is defined today by the International Gravity Standardization Net of 1971 (IGSN-71). The data supporting this network was measured in the 1950s and 60s using pendulum and spring-based gravimeter ties (plus some new ballistic absolute meters) to replace the prior protocol of referencing all gravity values to the earlier Potsdam value. Since this time, gravimeter technology has advanced significantly with the development and refinement of the FG-5 (the current standard of the industry) and again with the soon-to-be-available cold atom interferometric absolute gravimeters. This latest development is anticipated to provide improvement in the range of two orders of magnitude as compared to the measurement accuracy of technology utilized to develop ISGN-71. In this presentation, we will explore how the IGSN-71 might best be "modernized" given today's requirements and available instruments and resources. The National Geodetic Survey (NGS), along with other relevant US Government agencies, is concerned about establishing gravity control to establish and maintain high order geodetic networks as part of the nation's essential infrastructure. The need to modernize the nation's geodetic infrastructure was highlighted in "Precise Geodetic Infrastructure, National Requirements for a Shared Resource" National Academy of Science, 2010. The NGS mission, as dictated by Congress, is to establish and maintain the National Spatial Reference System, which includes gravity measurements. Absolute gravimeters measure the total gravity field directly and do not involve ties to other measurements. Periodic "intercomparisons" of multiple absolute gravimeters at reference gravity sites are used to constrain the behavior of the instruments to ensure that each would yield reasonably similar measurements of the same location (i.e. yield a sufficiently consistent datum when measured in disparate locales). New atomic interferometric gravimeters promise a significant

  18. Absolute magnitudes and phase coefficients of trans-Neptunian objects

    NASA Astrophysics Data System (ADS)

    Alvarez-Candal, A.; Pinilla-Alonso, N.; Ortiz, J. L.; Duffard, R.; Morales, N.; Santos-Sanz, P.; Thirouin, A.; Silva, J. S.

    2016-02-01

    Context. Accurate measurements of diameters of trans-Neptunian objects (TNOs) are extremely difficult to obtain. Thermal modeling can provide good results, but accurate absolute magnitudes are needed to constrain the thermal models and derive diameters and geometric albedos. The absolute magnitude, HV, is defined as the magnitude of the object reduced to unit helio- and geocentric distances and a zero solar phase angle and is determined using phase curves. Phase coefficients can also be obtained from phase curves. These are related to surface properties, but only few are known. Aims: Our objective is to measure accurate V-band absolute magnitudes and phase coefficients for a sample of TNOs, many of which have been observed and modeled within the program "TNOs are cool", which is one of the Herschel Space Observatory key projects. Methods: We observed 56 objects using the V and R filters. These data, along with those available in the literature, were used to obtain phase curves and measure V-band absolute magnitudes and phase coefficients by assuming a linear trend of the phase curves and considering a magnitude variability that is due to the rotational light-curve. Results: We obtained 237 new magnitudes for the 56 objects, six of which were without previously reported measurements. Including the data from the literature, we report a total of 110 absolute magnitudes with their respective phase coefficients. The average value of HV is 6.39, bracketed by a minimum of 14.60 and a maximum of -1.12. For the phase coefficients we report a median value of 0.10 mag per degree and a very large dispersion, ranging from -0.88 up to 1.35 mag per degree.

  19. Myocardial perfusion imaging with 201Tl.

    PubMed

    Pagnanelli, Robert A; Basso, Danny A

    2010-03-01

    The object of this review is to provide information about (201)Tl-thallous chloride in radionuclide myocardial perfusion imaging. This technique has experienced a recent resurgence because of the shortage of (99m)Tc. After reading this article, the technologist will be able to describe the properties and uptake mechanism of (201)Tl, the procedure for myocardial perfusion imaging with this agent, and the advantages and disadvantages of thallium, compared with the technetium agents. PMID:20159930

  20. Improved exercise myocardial perfusion during lidoflazine therapy

    SciTech Connect

    Shapiro, W.; Narahara, K.A.; Park, J.

    1983-11-01

    Lidoflazine is a synthetic drug with calcium-channel blocking effects. In a study of 6 patients with severe classic angina pectoris, single-blind administration of lidoflazine was associated with improved myocardial perfusion during exercise as determined by thallium-201 stress scintigraphy. These studies demonstrate that lidoflazine therapy is associated with relief of angina, an increased physical work capacity, and improved regional myocardial perfusion during exercise.

  1. Correlation of magnetic resonance signal characteristics and perfusion parameters assessed by volume perfusion computed tomography in hepatocellular carcinoma: Impact on lesion characterization

    PubMed Central

    Grözinger, Gerd; Bitzer, Michael; Syha, Roland; Ketelsen, Dominik; Nikolaou, Konstantin; Lauer, Ulrich; Horger, Marius

    2016-01-01

    AIM To find out if magnetic resonance (MR)-signal characteristics of hepatocellular carcinomas (HCC) correlate with perfusion parameters assessed by volume perfusion computed tomography (VPCT). METHODS From October 2009 to January 2014, 26 (mean age, 69.3 years) patients with 36 HCC lesions who underwent both VPCT and MR liver imaging were analysed. We compared signal intensity in the T1w- and T2w-images and wash-in/wash-out kinetics on post-contrast MR images with mean values of blood flow (BF, mL/100 mL per minute), blood volume (BV, mL/100 mL), k-trans (mL/100 mL per minute), arterial liver perfusion (mL/100 mL per minute), portal venous perfusion and hepatic perfusion index (HPI, %) obtained by VPCT. Signal intensity on magnetic resonance imaging (MRI) was classified hyper/iso/hypointense compared with surrounding liver parenchyma. RESULTS Signal intensity on native T1w- and T2w-images was hyper/iso/hypo in 4/16/16 and 21/14/1 lesions, respectively. Wash-in and wash-out contrast kinetics were found on MRI in 33 of 36 lesions (91.7%) and 25 of 36 lesions (69.4%), respectively. The latter was observed significantly more often in higher graded lesions (P < 0.005). HPI was 94.7% ± 6.5%. There was no significant relationship between lesion’s MR-signal intensity, MR signal combinations, size and any of the VPCT-perfusion parameters. However HPI was constantly high in all HCC lesions. CONCLUSION VPCT parameters add limited value to MR-lesion characterization. However in HCC lesions with atypical MR signal characteristics HPI can add a parameter to ensure HCC diagnosis. PMID:27551338

  2. Engine performance and the determination of absolute ceiling

    NASA Technical Reports Server (NTRS)

    Diehl, Walter S

    1924-01-01

    This report contains a brief study of the variation of engine power with temperature and pressure. The variation of propeller efficiency in standard atmosphere is obtained from the general efficiency curve which is developed in NACA report no. 168. The variation of both power available and power required are then determined and curves plotted, so that the absolute ceiling may be read directly from any known sea-level value of the ratio of power available to power required.

  3. On the Absolute Continuity of the Blackwell Measure

    NASA Astrophysics Data System (ADS)

    Bárány, Balázs; Kolossváry, István

    2015-04-01

    In 1957, Blackwell expressed the entropy of hidden Markov chains using a measure which can be characterised as an invariant measure for an iterated function system with place-dependent weights. This measure, called the Blackwell measure, plays a central role in understanding the entropy rate and other important characteristics of fundamental models in information theory. We show that for a suitable set of parameter values the Blackwell measure is absolutely continuous for almost every parameter in the case of binary symmetric channels.

  4. Perfusion visualization and analysis for pulmonary embolism

    NASA Astrophysics Data System (ADS)

    Vaz, Michael S.; Kiraly, Atilla P.; Naidich, David P.; Novak, Carol L.

    2005-04-01

    Given the nature of pulmonary embolism (PE), timely and accurate diagnosis is critical. Contrast enhanced high-resolution CT images allow physicians to accurately identify segmental and sub-segmental emboli. However, it is also important to assess the effect of such emboli on the blood flow in the lungs. Expanding upon previous research, we propose a method for 3D visualization of lung perfusion. The proposed method allows users to examine perfusion throughout the entire lung volume at a single glance, with areas of diminished perfusion highlighted so that they are visible independent of the viewing location. This may be particularly valuable for better accuracy in assessing the extent of hemodynamic alterations resulting from pulmonary emboli. The method also facilitates user interaction and may help identify small peripheral sub-segmental emboli otherwise overlooked. 19 patients referred for possible PE were evaluated by CT following the administration of IV contrast media. An experienced thoracic radiologist assessed the 19 datasets with 17 diagnosed as being positive for PE with multiple emboli. Since anomalies in lung perfusion due to PE can alter the distribution of parenchymal densities, we analyzed features collected from histograms of the computed perfusion maps and demonstrate their potential usefulness as a preliminary test to suggest the presence of PE. These histogram features also offer the possibility of distinguishing distinct patterns associated with chronic PE and may even be useful for further characterization of changes in perfusion or overall density resulting from associated conditions such as pneumonia or diffuse lung disease.

  5. Methodology for ventilation/perfusion SPECT.

    PubMed

    Bajc, Marika; Neilly, Brian; Miniati, Massimo; Mortensen, Jan; Jonson, Björn

    2010-11-01

    Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas over radiolabeled liquid aerosols are not restricted to the presence of obstructive lung disease. Radiolabeled macroaggregated human albumin is the imaging agent of choice for perfusion scintigraphy. An optimal combination of nuclide activities and acquisition times for ventilation and perfusion, collimators, and imaging matrix yields an adequate V/Q SPECT study in approximately 20 minutes of imaging time. The recommended protocol based on the patient remaining in an unchanged position during the initial ventilation study and the perfusion study allows presentation of matching ventilation and perfusion slices in all projections as well as in rotating volume images based upon maximum intensity projections. Probabilistic interpretation of V/Q SPECT should be replaced by a holistic interpretation strategy on the basis of all relevant information about the patient and all ventilation/perfusion patterns. PE is diagnosed when there is more than one subsegment showing a V/Q mismatch representing an anatomic lung unit. Apart from pulmonary embolism, other pathologies should be identified and reported, for example, obstructive disease, heart failure, and pneumonia. Pitfalls exist both with respect to imaging technique and scan interpretation. PMID:20920632

  6. Assignment of absolute stereochemistry by computation of optical rotation angles

    NASA Astrophysics Data System (ADS)

    Kondru, Rama Krishna

    We have developed simple wire and molecular orbital models to qualitatively and quantitatively understand optical rotation angles of molecules. We reported the first ab initio theoretical approach to determine the absolute stereochemistry of a complex natural product by calculating molar rotation angles, [M]D. We applied this method for an unambiguous assignment of the absolute stereochemistry of the hennoxazole A. A protocol analogous to population analysis was devised to analyze atomic contributions to the rotation angles for oxiranes, orthoesters, and other organic compounds. The molar rotations for an indoline, an indonone, menthol and menthone were calculated using ab inito methods and compared with experimental values. We reported the first prediction of the absolute configuration of a natural product, i.e. an a priori assignment of the relative and absolute stereochemistry of pitiamide A. Furthermore, we described a strategy that may help to establish structure-function relations for rotation angles by visualizing the electric and magnetic-field perturbations to a molecule's molecular orbitals.

  7. Hypothermic machine perfusion of the liver and the critical balance between perfusion pressures and endothelial injury.

    PubMed

    't Hart, N A; van der Plaats, A; Leuvenink, H G D; van Goor, H; Wiersema-Buist, J; Verkerke, G J; Rakhorst, G; Ploeg, R J

    2005-01-01

    Hypothermic machine perfusion (HMP) provides better protection against cold ischemic injury than cold storage in marginal donor kidneys. Also, in liver transplantation a switch from static cold storage to HMP could be beneficial as it would allow longer preservation times and the use of marginal donors. A critical question concerning application of HMP in liver preservation is the crucial balance between perfusion pressure and occurrence of endothelial injury. Rat livers were cold-perfused for 24 hours to study perfusion pressures for both hepatic artery and portal vein. Cold storage served as control and was compared to HMP-preserved livers using a mean arterial perfusion pressure of 25 mm Hg and a portal perfusion pressure of 4 mm Hg (25% of normothermic liver circulation) and to HMP at 50 mm Hg and 8 mm Hg perfusion, respectively (50% of normothermic liver circulation). UW solution was enriched with 14.9 micromol/L propidium iodide (PI) to stain for dead cells and with an additional 13.5 micromol/L acridine orange to stain for viable hepatocytes. A low PI-positive cell count was found using HMP at 25% of normal circulation compared to cold storage. The PI count was high for the HMP group perfused at just 50% of normal circulation compared to HMP at 25% and compared to cold storage. In summary, for liver HMP, perfusion at 25% showed complete perfusion with minimal cellular injury. HMP using perfusion pressures of 25 mm Hg for the hepatic artery and 4 mm Hg for the portal vein is feasible without induction of endothelial injury. PMID:15808634

  8. Determination of absolute structure using Bayesian statistics on Bijvoet differences

    PubMed Central

    Hooft, Rob W. W.; Straver, Leo H.; Spek, Anthony L.

    2008-01-01

    A new probabilistic approach is introduced for the determination of the absolute structure of a compound which is known to be enantiopure based on Bijvoet-pair intensity differences. The new method provides relative probabilities for different models of the chiral composition of the structure. The outcome of this type of analysis can also be cast in the form of a new value, along with associated standard uncertainty, that resembles the value of the well known Flack x parameter. The standard uncertainty we obtain is often about half of the standard uncertainty in the value of the Flack x parameter. The proposed formalism is suited in particular to absolute configuration determination from diffraction data of biologically active (pharmaceutical) compounds where the strongest resonant scattering signal often comes from oxygen. It is shown that a reliable absolute configuration assignment in such cases can be made on the basis of Cu Kα data, and in some cases even with carefully measured Mo Kα data. PMID:19461838

  9. A comparative analysis of the dependences of the hemodynamic parameters on changes in ROI's position in perfusion CT scans

    NASA Astrophysics Data System (ADS)

    Choi, Yong-Seok; Cho, Jae-Hwan; Namgung, Jang-Sun; Kim, Hyo-Jin; Yoon, Dae-Young; Lee, Han-Joo

    2013-05-01

    This study performed a comparative analysis of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and mean time-to-peak (TTP) obtained by changing the region of interest's (ROI) anatomical positions, during CT brain perfusion. We acquired axial source images of perfusion CT from 20 patients undergoing CT perfusion exams due to brain trauma. Subsequently, the CBV, CBF, MTT, and TTP values were calculated through data-processing of the perfusion CT images. The color scales for the CBV, CBF, MTT, and TTP maps were obtained using the image data. Anterior cerebral artery (ACA) was taken as the standard ROI for the calculations of the perfusion values. Differences in the hemodynamic average values were compared in a quantitative analysis by placing ROI and the dividing axial images into proximal, middle, and distal segments anatomically. By performing the qualitative analysis using a blind test, we observed changes in the sensory characteristics by using the color scales of the CBV, CBF, and MTT maps in the proximal, middle, and distal segments. According to the qualitative analysis, no differences were found in CBV, CBF, MTT, and TTP values of the proximal, middle, and distal segments and no changes were detected in the color scales of the the CBV, CBF, MTT, and TTP maps in the proximal, middle, and distal segments. We anticipate that the results of the study will useful in assessing brain trauma patients using by perfusion imaging.

  10. Absolute optical instruments without spherical symmetry

    NASA Astrophysics Data System (ADS)

    Tyc, Tomáš; Dao, H. L.; Danner, Aaron J.

    2015-11-01

    Until now, the known set of absolute optical instruments has been limited to those containing high levels of symmetry. Here, we demonstrate a method of mathematically constructing refractive index profiles that result in asymmetric absolute optical instruments. The method is based on the analogy between geometrical optics and classical mechanics and employs Lagrangians that separate in Cartesian coordinates. In addition, our method can be used to construct the index profiles of most previously known absolute optical instruments, as well as infinitely many different ones.

  11. Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Quini, Caio C.; Matos, Juliana F.; Próspero, André G.; Calabresi, Marcos Felipe F.; Zufelato, Nicholas; Bakuzis, Andris F.; Baffa, Oswaldo; Miranda, José Ricardo A.

    2015-04-01

    Alternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200 μL of magnetic nanoparticles with a concentration of 23 mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3 s and 20.6±7.1 s.

  12. Long-term outdoor cultivation by perfusing spent medium for biodiesel production from Chlorella minutissima.

    PubMed

    Oh, Sung Ho; Kwon, Min Chul; Choi, Woon Yong; Seo, Yong Chang; Kim, Ga Bin; Kang, Do Hyung; Lee, Shin Young; Lee, Hyeon Yong

    2010-08-01

    A unique perfusion process was developed to maintain high concentrations of marine alga, Chlorella minutissima. This method is based on recycling cells by continuous feeding with warm spent sea water from nuclear power plants, which has very similar properties as sea water. A temperature of at least 30 degrees C in a 200 L photo-bioreactor was maintained in this system by perfusion of the thermal plume for 80 days in the coldest season. The maximum cell concentration and total lipid content was 8.3 g-dry wt./L and 23.2 %, w/w, respectively, under mixotrophic conditions. Lipid production was found to be due to a partially or non-growth related process, which implies that large amounts of biomass are needed for a high accumulation of lipids within the cells. At perfusion rates greater than 1.5 L/h, the temperature of the medium inside the reactor was around 30 degrees C, which was optimal for cell growth. For this system, a perfusion rate of 2.8 L/h was determined to be optimal for maintaining rapid cell growth and lipid production during outdoor cultivation. It was absolutely necessary to maintain the appropriate perfusion rate so that the medium temperature was optimal for cell growth. In addition, the lipids produced using this process were shown to be feasible for biodiesel production since the lipid composition of C. minutissima grown under these conditions consisted of 17 % (w/w) of C(16) and 47% (w/w) of C(18). The combined results of this study clearly demonstrated that the discharged energy of the thermal plume could be reused to cultivate marine alga by maintaining a relatively constant temperature in an outdoor photo-bioreactor without the need for supplying any extra energy, which could allow for cheap production of biodiesel from waste energy. PMID:20547326

  13. Quantification of myocardial perfusion based on signal intensity of flow sensitized MRI

    NASA Astrophysics Data System (ADS)

    Abeykoon, Sumeda B.

    maximum percentage deviation is about 5%. Then the SI-method was used in comparison to a delayed enhanced method to qualitatively and quantitatively assess perfusion deficits in an ischemia-reperfusion (IR) mouse model. The infarcted region of the perfusion map is comparable to the hyper intense region of the delayed enhanced image of the IR mouse. The SI method also used to record a chronological comparison of perfusion on delta sarcoglycan null (DSG) mice. Perfusion of DSG and wild-type (WT) mice at ages of 12 weeks and 32 weeks were compared and percentage change of perfusion was estimated. The result shows that in DSG mice perfusion changes considerably. Finally, the SI method was implemented on a 3 Tesla Philip scanner by modifying to data acquisition method. The perfusion obtained in this is consistent with literature values but further adjustment of pulse sequence and modification of numerical solution is needed. The most important benefit of the SI method is that it reduces scan time 30%--40% and lessens motion artifacts of images compared to the T1 method. This study demonstrates that the signal intensity-based ASL method is a robust alternative to the conventional T1-method.

  14. Effects of Steroid Hormones on Sex Differences in Cerebral Perfusion

    PubMed Central

    Ghisleni, Carmen; Bollmann, Steffen; Biason-Lauber, Anna; Poil, Simon-Shlomo; Brandeis, Daniel; Martin, Ernst; Michels, Lars; Hersberger, Martin; Suckling, John

    2015-01-01

    Sex differences in the brain appear to play an important role in the prevalence and progression of various neuropsychiatric disorders, but to date little is known about the cerebral mechanisms underlying these differences. One widely reported finding is that women demonstrate higher cerebral perfusion than men, but the underlying cause of this difference in perfusion is not known. This study investigated the putative role of steroid hormones such as oestradiol, testosterone, and dehydroepiandrosterone sulphate (DHEAS) as underlying factors influencing cerebral perfusion. We acquired arterial spin labelling perfusion images of 36 healthy adult subjects (16 men, 20 women). Analyses on average whole brain perfusion levels included a multiple regression analysis to test for the relative impact of each hormone on the global perfusion. Additionally, voxel-based analyses were performed to investigate the sex difference in regional perfusion as well as the correlations between local perfusion and serum oestradiol, testosterone, and DHEAS concentrations. Our results replicated the known sex difference in perfusion, with women showing significantly higher global and regional perfusion. For the global perfusion, DHEAS was the only significant predictor amongst the steroid hormones, showing a strong negative correlation with cerebral perfusion. The voxel-based analyses revealed modest sex-dependent correlations between local perfusion and testosterone, in addition to a strong modulatory effect of DHEAS in cortical, subcortical, and cerebellar regions. We conclude that DHEAS in particular may play an important role as an underlying factor driving the difference in cerebral perfusion between men and women. PMID:26356576

  15. Assessment of myocardial perfusion and viability by positron emission tomography.

    PubMed

    Anagnostopoulos, Constantinos; Georgakopoulos, Alexandros; Pianou, Nikoletta; Nekolla, Stephan G

    2013-09-01

    An important evolution has taken place recently in the field of cardiovascular Positron Emission Tomography (PET) imaging. Being originally a highly versatile research tool that has contributed significantly to advance our understanding of cardiovascular physiology and pathophysiology, PET has gradually been incorporated into the clinical cardiac imaging portfolio contributing to diagnosis and management of patients investigated for coronary artery disease (CAD). PET myocardial perfusion imaging (MPI) has an average sensitivity and specificity around 90% for the detection of angiographically significant CAD and it is also a very accurate technique for prognostication of patients with suspected or known CAD. In clinical practice, Rubidium-82 ((82)Rb) is the most widely used radiopharmaceutical for MPI that affords also accurate and reproducible quantification in absolute terms (ml/min/g) comparable to that obtained by cyclotron produced tracers such as Nitrogen-13 ammonia ((13)N-ammonia) and Oxygen-15 labeled water ((15)O-water). Quantification increases sensitivity for detection of multivessel CAD and it may also be helpful for detection of early stages of atherosclerosis or microvascular dysfunction. PET imaging combining perfusion with myocardial metabolism using (18)F-Fluorodeoxyglucose ((18)F FDG), a glucose analog, is an accurate standard for assessment of myocardial hibernation and risk stratification of patients with left ventricular dysfunction of ischemic etiology. It is helpful for guiding management decisions regarding revascularization or medical treatment and predicting improvement of symptoms, exercise capacity and quality of life post-revascularization. The strengths of PET can be increased further with the introduction of hybrid scanners, which combine PET with computed tomography (PET/CT) or with magnetic resonance imaging (PET/MRI) offering integrated morphological, biological and physiological information and hence, comprehensive evaluation of

  16. Absolute magnitudes of trans-neptunian objects

    NASA Astrophysics Data System (ADS)

    Duffard, R.; Alvarez-candal, A.; Pinilla-Alonso, N.; Ortiz, J. L.; Morales, N.; Santos-Sanz, P.; Thirouin, A.

    2015-10-01

    Accurate measurements of diameters of trans- Neptunian objects are extremely complicated to obtain. Radiomatric techniques applied to thermal measurements can provide good results, but precise absolute magnitudes are needed to constrain diameters and albedos. Our objective is to measure accurate absolute magnitudes for a sample of trans- Neptunian objects, many of which have been observed, and modelled, by the "TNOs are cool" team, one of Herschel Space Observatory key projects grantes with ~ 400 hours of observing time. We observed 56 objects in filters V and R, if possible. These data, along with data available in the literature, was used to obtain phase curves and to measure absolute magnitudes by assuming a linear trend of the phase curves and considering magnitude variability due to rotational light-curve. In total we obtained 234 new magnitudes for the 56 objects, 6 of them with no reported previous measurements. Including the data from the literature we report a total of 109 absolute magnitudes.

  17. A New Gimmick for Assigning Absolute Configuration.

    ERIC Educational Resources Information Center

    Ayorinde, F. O.

    1983-01-01

    A five-step procedure is provided to help students in making the assignment absolute configuration less bothersome. Examples for both single (2-butanol) and multi-chiral carbon (3-chloro-2-butanol) molecules are included. (JN)

  18. GPU-accelerated voxelwise hepatic perfusion quantification.

    PubMed

    Wang, H; Cao, Y

    2012-09-01

    Voxelwise quantification of hepatic perfusion parameters from dynamic contrast enhanced (DCE) imaging greatly contributes to assessment of liver function in response to radiation therapy. However, the efficiency of the estimation of hepatic perfusion parameters voxel-by-voxel in the whole liver using a dual-input single-compartment model requires substantial improvement for routine clinical applications. In this paper, we utilize the parallel computation power of a graphics processing unit (GPU) to accelerate the computation, while maintaining the same accuracy as the conventional method. Using compute unified device architecture-GPU, the hepatic perfusion computations over multiple voxels are run across the GPU blocks concurrently but independently. At each voxel, nonlinear least-squares fitting the time series of the liver DCE data to the compartmental model is distributed to multiple threads in a block, and the computations of different time points are performed simultaneously and synchronically. An efficient fast Fourier transform in a block is also developed for the convolution computation in the model. The GPU computations of the voxel-by-voxel hepatic perfusion images are compared with ones by the CPU using the simulated DCE data and the experimental DCE MR images from patients. The computation speed is improved by 30 times using a NVIDIA Tesla C2050 GPU compared to a 2.67 GHz Intel Xeon CPU processor. To obtain liver perfusion maps with 626 400 voxels in a patient's liver, it takes 0.9 min with the GPU-accelerated voxelwise computation, compared to 110 min with the CPU, while both methods result in perfusion parameters differences less than 10(-6). The method will be useful for generating liver perfusion images in clinical settings. PMID:22892645

  19. An efficient polyenergetic SART (pSART) reconstruction algorithm for quantitative myocardial CT perfusion

    SciTech Connect

    Lin, Yuan Samei, Ehsan

    2014-02-15

    Purpose: In quantitative myocardial CT perfusion imaging, beam hardening effect due to dense bone and high concentration iodinated contrast agent can result in visible artifacts and inaccurate CT numbers. In this paper, an efficient polyenergetic Simultaneous Algebraic Reconstruction Technique (pSART) was presented to eliminate the beam hardening artifacts and to improve the CT quantitative imaging ability. Methods: Our algorithm made threea priori assumptions: (1) the human body is composed of several base materials (e.g., fat, breast, soft tissue, bone, and iodine); (2) images can be coarsely segmented to two types of regions, i.e., nonbone regions and noniodine regions; and (3) each voxel can be decomposed into a mixture of two most suitable base materials according to its attenuation value and its corresponding region type information. Based on the above assumptions, energy-independent accumulated effective lengths of all base materials can be fast computed in the forward ray-tracing process and be used repeatedly to obtain accurate polyenergetic projections, with which a SART-based equation can correctly update each voxel in the backward projecting process to iteratively reconstruct artifact-free images. This approach effectively reduces the influence of polyenergetic x-ray sources and it further enables monoenergetic images to be reconstructed at any arbitrarily preselected target energies. A series of simulation tests were performed on a size-variable cylindrical phantom and a realistic anthropomorphic thorax phantom. In addition, a phantom experiment was also performed on a clinical CT scanner to further quantitatively validate the proposed algorithm. Results: The simulations with the cylindrical phantom and the anthropomorphic thorax phantom showed that the proposed algorithm completely eliminated beam hardening artifacts and enabled quantitative imaging across different materials, phantom sizes, and spectra, as the absolute relative errors were reduced

  20. FATTY ACID CHAIN-ELONGATION IN PERFUSED RAT HEART: SYNTHESIS OF STEAROYLCARNITINE FROM PERFUSED PALMITATE

    PubMed Central

    Kerner, Janos; Minkler, Paul E.; Lesnefsky, Edward J.; Hoppel, Charles L.

    2009-01-01

    Rat hearts perfused for up to 60 min in the working mode with palmitate, but not with glucose, resulted in substantial formation of palmitoylcarnitine and stearoylcarnitine. To test whether lipolysis of endogenous lipids was responsible for the increased stearoylcarnitine content or whether some of the perfused palmitate underwent chain elongation, hearts were perfused with hexadecanoic-16,16,16-d3 acid (M+3). The pentafluorophenacyl ester of deuterium labeled stearoylcarnitine had an M+3 (639.4 m/z) compared to the unlabeled M+0 (636.3 m/z) consistent with a direct chain elongation of the perfused palmitate. Furthermore, the near equal isotope enrichment of palmitoyl- (90.2 ± 5.8 %) and stearoylcarnitine (78.0 ± 7.1 %) suggest that both palmitoyl- and stearoyl-CoA have ready access to mitochondrial carnitine palmitoyltransferase and that most of the stearoylcarnitine is derived from the perfused palmitate. PMID:17761175

  1. GNSS Absolute Antenna Calibration at the National Geodetic Survey

    NASA Astrophysics Data System (ADS)

    Mader, G. L.; Bilich, A. L.; Geoghegan, C.

    2011-12-01

    Geodetic GNSS applications routinely demand millimeter precision and extremely high levels of accuracy. To achieve these accuracies, measurement and instrument biases at the centimeter to millimeter level must be understood. One of these biases is the antenna phase center, the apparent point of signal reception for a GNSS antenna. It has been well established that phase center patterns differ between antenna models and manufacturers; additional research suggests that the addition of a radome or the choice of antenna mount can significantly alter those a priori phase center patterns. For the more demanding GNSS positioning applications and especially in cases of mixed-antenna networks, it is all the more important to know antenna phase center variations as a function of both elevation and azimuth in the antenna reference frame and incorporate these models into analysis software. To help meet the needs of the high-precision GNSS community, the National Geodetic Survey (NGS) now operates an absolute antenna calibration facility. Located in Corbin, Virginia, this facility uses field measurements and actual GNSS satellite signals to quantitatively determine the carrier phase advance/delay introduced by the antenna element. The NGS facility was built to serve traditional NGS constituents such as the surveying and geodesy communities, however calibration services are open and available to all GNSS users as the calibration schedule permits. All phase center patterns computed by this facility will be publicly available and disseminated in both the ANTEX and NGS formats. We describe the NGS calibration facility, and discuss the observation models and strategy currently used to generate NGS absolute calibrations. We demonstrate that NGS absolute phase center variation (PCV) patterns are consistent with published values determined by other absolute antenna calibration facilities, and compare absolute calibrations to the traditional NGS relative calibrations.

  2. Cortical perfusion index: A predictor of acute rejection in transplanted kidneys

    SciTech Connect

    Atkins, H.L.; Oster, Z.H.; Anaise, D.; Wein, S.; Waltzer, W.; Gonder, A.; Cooch, E.; Rapaport, F.T.

    1985-05-01

    The presently available non-invasive methods for the diagnosis of acute rejection crisis (ARC) of renal transplants are not satisfactory. However, the need for such a test is of paramount clinical importance. A prospective study of 74 post-transplantation events in renal allograft recipients was performed. Clinical, surgical exploration and biopsy data were correlated with TC-99m DTPA scintigraphy using the following indices: Global perfusion index (GPI), cortical perfusion index (CPI), medullary perfusion index (MPI), the peak-to-plateau ratio (P/P), iliac artery peak to renal peak time (delta-P) and washout half-time (T1/2). Of the 74 events, 24 were proven to be due to acute rejection crisis (ARC), 13 were of ureteral obstruction, 18 various nephropathies and 19 in stable renal transplant function. The P/P, delta-P and T1/2 were not good predictors of ARC; the sensitivity was 79%, 79% and 80% respectively. The sensitivity of the GPI was 58% and the specificity was 87%. The cortical perfusion index rated better: specificity=84% and sensitivity=87%. However, the best indicator of ARC seemed to be the percent increase in cortical perfusion index over previous values obtained during stable graft function. Thus the sensitivity was found to be 91% and specificity was 96%. The difference between global and cortical perfusion indices reflects shunting of blood for cortex to medulla. This study suggest that the cortical perfusion index (CPI) and the percent increase in CPI can be used to non-invasively diagnose acute renal allograft rejection.

  3. Absolute photoionization cross-section of the propargyl radical

    SciTech Connect

    Savee, John D.; Welz, Oliver; Taatjes, Craig A.; Osborn, David L.; Soorkia, Satchin; Selby, Talitha M.

    2012-04-07

    Using synchrotron-generated vacuum-ultraviolet radiation and multiplexed time-resolved photoionization mass spectrometry we have measured the absolute photoionization cross-section for the propargyl (C{sub 3}H{sub 3}) radical, {sigma}{sub propargyl}{sup ion}(E), relative to the known absolute cross-section of the methyl (CH{sub 3}) radical. We generated a stoichiometric 1:1 ratio of C{sub 3}H{sub 3} : CH{sub 3} from 193 nm photolysis of two different C{sub 4}H{sub 6} isomers (1-butyne and 1,3-butadiene). Photolysis of 1-butyne yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(26.1{+-}4.2) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(23.4{+-}3.2) Mb, whereas photolysis of 1,3-butadiene yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(23.6{+-}3.6) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(25.1{+-}3.5) Mb. These measurements place our relative photoionization cross-section spectrum for propargyl on an absolute scale between 8.6 and 10.5 eV. The cross-section derived from our results is approximately a factor of three larger than previous determinations.

  4. Radionuclide cerebral perfusion imaging: Normal pattern

    SciTech Connect

    Goldsmith, S.J.; Stritzke, P.; Losonczy, M.; Vallabhajosula, S.; Holan, V.; DaCosta, M.; Muzinic, M.

    1991-12-31

    Regional cerebral perfusion imaging using a new class of {sup 99m}Tc and {sup 123}I labeled compounds which traverse the blood brain barrier and SPECT imaging technology provides an opportunity to assess this physiologic phenomenon during normal cerebral function and as a manifestation of disease in the central nervous system disease. These applications pose a challenge to the nuclear medicine physician for several reasons: (a) the complex and somewhat unfamiliar functional anatomy, (b) the marked regional differences in regional cerebral perfusion at rest, (c) the lack of understanding of the effect of variations in ambient conditions on regional cerebral perfusion. The difficulties in interpretation are augmented by the display itself. There is frequently no difficulty in differentiating between gray and white matter. However, the frequently used {open_quotes}hot body{close_quotes} color maps, introduce a good deal of contrast, producing displays with apparent interruption in regional cortical perfusion whereas black and white displays provide minimal contrast in the regional cortical activity. The authors sought to define how much variation in regional cerebral perfusion is {open_quotes}allowed{close_quotes} under controlled conditions, to establish a basis to interpret if changes in the environment, psychological interventions, or disease states are accompanied by a measurable change. 2 figs., 1 tab.

  5. Pulmonary perfusion during anesthesia and mechanical ventilation.

    PubMed

    Hedenstierna, G

    2005-06-01

    Cardiac output and the pulmonary perfusion can be affected by anesthesia and by mechanical ventilation. The changes contribute to impeded oxygenation of the blood. The major determinant of perfusion distribution in the lung is the relation between alveolar and pulmonary capillary pressures. Perfusion increases down the lung, due to hydrostatic forces. Since atelectasis is located in dependent lung regions, perfusion of non-ventilated lung parenchyma is common, producing shunt of around 8-10% of cardiac output. In addition, non-gravitational inhomogeneity of perfusion, that can be greater than the gravitational inhomogeneity, adds to impeded oxygenation of blood. Essentially all anaesthetics exert some, although mild, cardiodepressant action with one exception, ketamine. Ketamine may also increase pulmonary artery pressure, whereas other agents have little effect on pulmonary vascular tone. Mechanical ventilation impedes venous return and pushes blood flow downwards to dependent lung regions, and the effect may be striking with higher levels of PEEP. During one-lung anesthesia, there is shunt blood flow both in the non-ventilated and the ventilated lung, and shunt can be much larger in the ventilated lung than thought of. Recruitment manoeuvres shall be directed to the ventilated lung and other physical and pharmacological measures can be taken to manipulate blood flow in one lung anesthesia. PMID:15886595

  6. Perfusion harmonic imaging of the human brain

    NASA Astrophysics Data System (ADS)

    Metzler, Volker H.; Seidel, Guenter; Wiesmann, Martin; Meyer, Karsten; Aach, Til

    2003-05-01

    The fast visualisation of cerebral microcirculation supports diagnosis of acute cerebrovascular diseases. However, the commonly used CT/MRI-based methods are time consuming and, moreover, costly. Therefore we propose an alternative approach to brain perfusion imaging by means of ultrasonography. In spite of the low signal/noise-ratio of transcranial ultrasound and the high impedance of the skull, flow images of cerebral blood flow can be derived by capturing the kinetics of appropriate contrast agents by harmonic ultrasound image sequences. In this paper we propose three different methods for human brain perfusion imaging, each of which yielding flow images indicating the status of the patient's cerebral microcirculation by visualising local flow parameters. Bolus harmonic imaging (BHI) displays the flow kinetics of bolus injections, while replenishment (RHI) and diminution harmonic imaging (DHI) compute flow characteristics from contrast agent continuous infusions. RHI measures the contrast agents kinetics in the influx phase and DHI displays the diminution kinetics of the contrast agent acquired from the decay phase. In clinical studies, BHI- and RHI-parameter images were found to represent comprehensive and reproducible distributions of physiological cerebral blood flow. For DHI it is shown, that bubble destruction and hence perfusion phenomena principally can be displayed. Generally, perfusion harmonic imaging enables reliable and fast bedside imaging of human brain perfusion. Due to its cost efficiency it complements cerebrovascular diagnostics by established CT/MRI-based methods.

  7. Effects of vascular elastosis on uterine blood flow and perfusion in anesthetized mares.

    PubMed

    Esteller-Vico, A; Liu, I K M; Vaughan, B; Steffey, E P; Brosnan, R J

    2015-04-01

    In the uterus of the mare, data obtained using transrectal Doppler ultrasonography indicate that uterine blood flow (UBF) is dynamic and changes throughout the estrous cycle. Degenerative lesions in the uterus are associated with subfertility and infertility. Among these lesions, vascular elastosis has been reported in aged, multiparous, and infertile mares. Angiosis of the uterine vasculature could potentially compromise UBF. The objectives of this experiment are to determine levels of UBF and perfusion of reproductively healthy mares and compare them to levels of subfertile/infertile mares affected by uterine vascular elastosis. Twenty mares were classified on the basis of degree of vascular degeneration and stage of cycle. A fluorescent microsphere technique was used to measure reproductive organ perfusion, where microspheres were injected into the left ventricle of the heart and became trapped in capillary beds in proportion to blood flow and tissue perfusion. The reproductive tract was removed, sectioned, and the fluorescent intensity evaluated to measure blood flow and perfusion. Additionally, full-thickness samples of the uterine wall were examined postmortem to further assess the degree of vascular degeneration in all layers of uterine wall. The mean value of uterine perfusion for the control mares during estrus (n = 5) was higher (P < 0.01) than that during diestrus (n = 5); 17.6 and 11.9 mL/min/100g, respectively. For the subfertile/infertile mares, the mean value of tissue perfusion was not different (P > 0.05) during estrus (n = 5) and diestrus (n = 5); 5.9 and 7.2 mL/min/100g, respectively. Uterine perfusion in subfertile/infertile mares affected by elastosis was lower than that of control mares during both estrus (P < 0.01) and diestrus (P < 0.01). The differences in baseline levels of perfusion between the control and elastosis groups indicate that elastosis of the uterine vasculature is associated with decreased uterine perfusion

  8. Absolute magnitude calibration using trigonometric parallax - Incomplete, spectroscopic samples

    NASA Technical Reports Server (NTRS)

    Ratnatunga, Kavan U.; Casertano, Stefano

    1991-01-01

    A new numerical algorithm is used to calibrate the absolute magnitude of spectroscopically selected stars from their observed trigonometric parallax. This procedure, based on maximum-likelihood estimation, can retrieve unbiased estimates of the intrinsic absolute magnitude and its dispersion even from incomplete samples suffering from selection biases in apparent magnitude and color. It can also make full use of low accuracy and negative parallaxes and incorporate censorship on reported parallax values. Accurate error estimates are derived for each of the fitted parameters. The algorithm allows an a posteriori check of whether the fitted model gives a good representation of the observations. The procedure is described in general and applied to both real and simulated data.

  9. In-flight Absolute Radiometric Calibration of the Thematic Mapper

    NASA Technical Reports Server (NTRS)

    Castle, K. R.; Holm, R. G.; Kastner, C. J.; Palmer, J. M.; Slater, P. N.; Dinguirard, M.; Ezra, C. E.; Jackson, D.; Savage, R. K.

    1984-01-01

    The Thematic Mapper (TM) multispectral scanner system was placed into Earth orbit on July 16, 1982, as part of NASA's LANDSAT 4 payload. To determine temporal changes of the absolute radiometric calibration of the entire system in flight, spectroradiometric measurements of the ground and the atmosphere are made simultaneously with TM image acquisitions over the White Sands, New Mexico area. By entering the measured values into an atmospheric radiative transfer program, the radiance levels at the entrance pupil of the TM in four of the TM spectral bands are determined. These levels are compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors. By reference to an adjacent, larger uniform area, the calibration is extended to all 16 detectors in each of the three bands.

  10. Absolute measurement of the extreme UV solar flux

    NASA Technical Reports Server (NTRS)

    Carlson, R. W.; Ogawa, H. S.; Judge, D. L.; Phillips, E.

    1984-01-01

    A windowless rare-gas ionization chamber has been developed to measure the absolute value of the solar extreme UV flux in the 50-575-A region. Successful results were obtained on a solar-pointing sounding rocket. The ionization chamber, operated in total absorption, is an inherently stable absolute detector of ionizing UV radiation and was designed to be independent of effects from secondary ionization and gas effusion. The net error of the measurement is + or - 7.3 percent, which is primarily due to residual outgassing in the instrument, other errors such as multiple ionization, photoelectron collection, and extrapolation to the zero atmospheric optical depth being small in comparison. For the day of the flight, Aug. 10, 1982, the solar irradiance (50-575 A), normalized to unit solar distance, was found to be 5.71 + or - 0.42 x 10 to the 10th photons per sq cm sec.

  11. In-flight absolute radiometric calibration of the thematic mapper

    NASA Technical Reports Server (NTRS)

    Castle, K. R.; Holm, R. G.; Kastner, C. J.; Palmer, J. M.; Slater, P. N.; Dinguirard, M.; Ezra, C. E.; Jackson, R. D.; Savage, R. K.

    1984-01-01

    In order to determine temporal changes of the absolute radiometric calibration of the entire TM system in flight spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM image collections over the White Sands, New Mexico area. By entering the measured values in an atmospheric radiative transfer program, the radiance levels in four of the spectral bands of the TM were determined, band 1:0.45 to 0.52 micrometers, band 2:0.53 to 0.61 micrometers band 3:0.62 to 0.70 micrometers and 4:0.78 to 0.91 micrometers. These levels were compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors.

  12. In-flight absolute radiometric calibration of the Thematic Mapper

    NASA Technical Reports Server (NTRS)

    Castle, K. R.; Holm, R. G.; Kastner, C. J.; Palmer, J. M.; Slater, P. N.; Dinguirard, M.; Ezra, C. E.; Jackson, R. D.; Savage, R. K.

    1984-01-01

    In order to determine temporal changes of the absolute radiometric calibration of the entire TM system in flight spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM image collections over the White Sands, NM area. By entering the measured values in an atmospheric radiative transfer program, the radiance levels in four of the spectral bands of the TM were determined, band 1: 0.45 to 0.52 micrometers, band 2: 0.53 to 0.61 micrometers, band 3: 0.62 to 0.70 micrometers, and 4: 0.78 to 0.91 micrometers. These levels were compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors. Previously announced in STAR as N84-15633

  13. Partial volume correction of brain perfusion estimates using the inherent signal data of time-resolved arterial spin labeling.

    PubMed

    Ahlgren, André; Wirestam, Ronnie; Petersen, Esben Thade; Ståhlberg, Freddy; Knutsson, Linda

    2014-09-01

    Quantitative perfusion MRI based on arterial spin labeling (ASL) is hampered by partial volume effects (PVEs), arising due to voxel signal cross-contamination between different compartments. To address this issue, several partial volume correction (PVC) methods have been presented. Most previous methods rely on segmentation of a high-resolution T1 -weighted morphological image volume that is coregistered to the low-resolution ASL data, making the result sensitive to errors in the segmentation and coregistration. In this work, we present a methodology for partial volume estimation and correction, using only low-resolution ASL data acquired with the QUASAR sequence. The methodology consists of a T1 -based segmentation method, with no spatial priors, and a modified PVC method based on linear regression. The presented approach thus avoids prior assumptions about the spatial distribution of brain compartments, while also avoiding coregistration between different image volumes. Simulations based on a digital phantom as well as in vivo measurements in 10 volunteers were used to assess the performance of the proposed segmentation approach. The simulation results indicated that QUASAR data can be used for robust partial volume estimation, and this was confirmed by the in vivo experiments. The proposed PVC method yielded probable perfusion maps, comparable to a reference method based on segmentation of a high-resolution morphological scan. Corrected gray matter (GM) perfusion was 47% higher than uncorrected values, suggesting a significant amount of PVEs in the data. Whereas the reference method failed to completely eliminate the dependence of perfusion estimates on the volume fraction, the novel approach produced GM perfusion values independent of GM volume fraction. The intra-subject coefficient of variation of corrected perfusion values was lowest for the proposed PVC method. As shown in this work, low-resolution partial volume estimation in connection with ASL perfusion

  14. Noninvasive testing of cerebral perfusion reserve prior to coronary artery bypass graft surgery

    SciTech Connect

    Levine, R.L.; Lagreze, H.L.; Berkoff, H.A.; Turnipseed, W.D.; Hanson, J.M.; Sunderland, J.J.; Nickles, R.J.; Rowe, B.R.

    1988-05-01

    Cerebral perfusion reserve testing using fluorine-18-fluoromethane and positron emission tomographic brain scanning to define cerebral blood flow abnormalities was performed in 5 patients being considered for combined coronary and carotid reconstructive surgery. Blood flow testing during normocapnia and following hypercapnia was utilized in these patients to determine the hemodynamic significance of known extracranial carotid artery occlusive lesions. Reserve diminution in 2 of these patients prompted combined surgery, whereas normal reserve values in the other 3 prompted coronary surgery alone. Results obtained in this preliminary series show how preoperative noninvasive testing of cerebral perfusion reserve adds to the diagnostic evaluation of patients with widespread vascular disease.

  15. Flicker stimulated retinal perfusion changes assessed with high-speed Doppler tomography

    NASA Astrophysics Data System (ADS)

    Schmoll, Tilman; Singh, Amardeep S. G.; Frily, Karine; Blatter, Cedric; Villiger, Martin; Pache, Christoph; Lasser, Theo; Leitgeb, R. A.

    2010-02-01

    We developed a high speed Doppler tomography system together with flow extraction algorithms that provide a flexible tool to assess retinal perfusion. The aim of the present study is to stimulate perfusion by flickering with light of adjustable color and to measure changes depending on light frequency and flicker location. We observed relative changes in arterial flow velocity during flicker stimulation up to 50%. We found in arteries close to the optic nerve head the highest flicker response at a frequency of 8Hz. We believe that a multimodal functional imaging concept is of high value for an accurate and early diagnosis and understanding of retinal pathologies and pathogenesis.

  16. In-vivo regional myocardial perfusion measurements in a porcine model by ECG-gated multislice computed tomography

    NASA Astrophysics Data System (ADS)

    Stantz, Keith M.; Liang, Yun; Meyer, Cristopher A.; Teague, Shawn; Stecker, Michael; Hutchins, Gary; McLennan, Gordon; Persohn, Scott

    2003-05-01

    Purpose: To evaluate whether functional multi-slice computed tomography (MSCT) can identify regional areas of normally perfused and ischemic myocardium in a porcine model. Material and Methods: Three out bred pigs, two of which had ameroids surgically implanted to constrict flow within the LAD and LCx coronary arteries, were injected with 25 mL of iopromide (Isovue) at a rate of 5 mL/second via the femoral or jugular vein. Sixty axial scans along the short axis of the heart was acquired on a 16-slice CT scanner (Philips MX8000-IDT) triggered at end-diastole of the cardiac cycle and acquiring an image within 270 msec. A second series of scans were taken after an intravenous injection of a vasodilator, 150 μg/kg/min of adenosine. ROIs were drawn around the myocardial tissue and the resulting time-density curves were used to extract perfusion values. Results: Determination of the myocardial perfusion and fractional blood volume implementing three different perfusion models. A 5-point averaging or 'smoothing' algorithm was employed to effectively filter the data due to its noisy nature. The (preliminary) average perfusion and fractional blood volume values over selected axial slices for the pig without an artificially induced stenosis were measured to be 84 +/- 22 mL/min/100g-tissue and 0.17 +/- 0.04 mL/g-tissue, the former is consistent with PET scan and EBCT results. The pig with a stenosis in the left LAD coronary artery showed a reduced global perfusion value -- 45 mL/min/100g-tissue. Correlations in regional perfusion values relative to the stenosis were weak. During the infusion of adenosine, averaged perfusion values for the three subjects increased by 46 (+/-45) percent, comparable to increases measured with PET. Conclusion: Quantifying global perfusion values using MDCT appear encouraging. Future work will focus resolving the systematic effects from noise due to signal fluctuation from the porcine tachyardia (80-93 BPM) and provide a more robust measurement

  17. Kinetics of reversible-sequestration of leukocytes by the isolated perfused rat lung

    SciTech Connect

    Goliaei, B.

    1980-08-01

    The kinetics and morphology of sequestration and margination of rat leukocytes were studied using an isolated perfused and ventilated rat lung preparation. Whole rat blood, bone marrow suspension, or leukocyte suspensions, were used to perfuse the isolated rat lung. The lung was also perfused with latex particle suspensions and the passage of particles through the lung capillaries was studied. When a leukocyte suspension was perfused through the lung in the single-pass mode, the rate of sequestration decreased as more cells were perfused. In contrast, latex particles of a size comparable to that of leukocytes were totally stopped by the lung. When the leukocyte suspension was recirculated through the lung, cells were rapidly removed from circulation until a steady state was reached, after which no net removal of cells by the lung occurred. These results indicate that leukocytes are reversibly sequestered from circulation. The sequestered cells marginated and attached to the luminal surface of the endothelium of post-capillary venules and veins. A mathematical model was developed based on the assumption that the attachment and detachment of leukocytes to blood vessel walls follows first-order kinetics. The model correctly predicts the following characteristics of the system: (a) the kinetics of the sequestration of leukocytes by the lung; (b) the existence of a steady state when a suspension of leukocytes is recirculated through the lung; and (c) the independence of the fraction of cells remaining in circulation from the starting concentration for all values of starting concentration. (ERB)

  18. Quantitative Cardiac Perfusion: A Noninvasive Spin-labeling Method That Exploits Coronary Vessel Geometry1

    PubMed Central

    Reeder, Scott B.; Atalay, Michael K.; McVeigh, Elliot R.; Zerhouni, Elias A.; Forder, John R.

    2007-01-01

    PURPOSE: To quantitate myocardial arterial perfusion with a noninvasive magnetic resonance (MR) imaging technique that exploits the geometry of coronary vessel anatomy. MATERIALS AND METHODS: MR imaging was performed with a spinlabeling method in six arrested rabbit hearts at 4.7 T. Selective inversion of magnetization in the short-axis imaging section along with all myocardium apical to that section produces signal enhancement from arterial perfusion. A linescan protocol was used for validation of flow enhancement. Flow was quantitated from two images and validated with spin-echo (SE) imaging. Regional perfusion defects were created by means of coronary artery ligation and delineated with gadolinium-enhanced imaging. RESULTS: Linescan estimates of T1 obtained at physiologic flows agreed with model predictions. Flow-induced signal enhancement measured on SE images also agreed with expected values. Finally, perfusion abnormalities created by means of coronary artery ligation were detected. CONCLUSION: This spin-labeling method provides quantitative estimates of myocardial arterial perfusion in this model and may hold promise for clinical applications. PMID:8657907

  19. Jasminum flexile flower absolute from India--a detailed comparison with three other jasmine absolutes.

    PubMed

    Braun, Norbert A; Kohlenberg, Birgit; Sim, Sherina; Meier, Manfred; Hammerschmidt, Franz-Josef

    2009-09-01

    Jasminum flexile flower absolute from the south of India and the corresponding vacuum headspace (VHS) sample of the absolute were analyzed using GC and GC-MS. Three other commercially available Indian jasmine absolutes from the species: J. sambac, J. officinale subsp. grandiflorum, and J. auriculatum and the respective VHS samples were used for comparison purposes. One hundred and twenty-one compounds were characterized in J. flexile flower absolute, with methyl linolate, benzyl salicylate, benzyl benzoate, (2E,6E)-farnesol, and benzyl acetate as the main constituents. A detailed olfactory evaluation was also performed. PMID:19831037

  20. Cardiac tissue engineering using perfusion bioreactor systems

    PubMed Central

    Radisic, Milica; Marsano, Anna; Maidhof, Robert; Wang, Yadong; Vunjak-Novakovic, Gordana

    2009-01-01

    This protocol describes tissue engineering of synchronously contractile cardiac constructs by culturing cardiac cell populations on porous scaffolds (in some cases with an array of channels) and bioreactors with perfusion of culture medium (in some cases supplemented with an oxygen carrier). The overall approach is ‘biomimetic’ in nature as it tends to provide in vivo-like oxygen supply to cultured cells and thereby overcome inherent limitations of diffusional transport in conventional culture systems. In order to mimic the capillary network, cells are cultured on channeled elastomer scaffolds that are perfused with culture medium that can contain oxygen carriers. The overall protocol takes 2–4 weeks, including assembly of the perfusion systems, preparation of scaffolds, cell seeding and cultivation, and on-line and end-point assessment methods. This model is well suited for a wide range of cardiac tissue engineering applications, including the use of human stem cells, and high-fidelity models for biological research. PMID:18388955

  1. Perfusion and ventilation of isolated canine lungs

    PubMed Central

    Otto, T. J.; Trenkner, M.; Stopczyk, A.; Gawdziński, M.; Chełstowska, B.

    1968-01-01

    In order to evaluate methods of preserving lungs for use in transplantation, experiments on 28 mongrel dogs were carried out. Two methods were tried—first, mechanical respiration of isolated lungs under deep hypothermia, with the vascular bed filled with blood; and, secondly, the perfusion of isolated lungs with the aid of a modified DeWall's apparatus. Allogenic transplantations of lungs preserved in both ways were carried out. Gasometric and histological examinations of preserved lungs, before and after transplantation, were performed. The best results were obtained with perfusion under hypothermic conditions; ventilation without perfusion resulted in failure. Lung transplantation was successful when, after being preserved, the lung remained unchanged. Major discrepancies between the macroscopic and microscopic findings in preserved lungs were observed. An original classification of the changes occurring in preserved lungs is proposed. PMID:4886091

  2. Perfusion in Britain: the early days.

    PubMed

    Braimbridge, Mark V

    2004-07-01

    Experimental perfusion was largely the province of Germany in the nineteenth century but in the mid-twentieth century the focus of perfusion switched to the USA with the explosive clinical advances of Lillehei, Kirklin and Cooley. British clinical perfusion started with Melrose in 1953 at the Postgraduate Medical School in London but, as in other centres at that time, stopped due to the high mortality. The arrival of hands-on experience of American expertise via returning research fellows and other visitors to the USA enabled the first successful on-going series to begin at the Hammersmith Hospital with Cleland in 1957 and then to spread around the country. The various problems of those early 1950s days are described in the units starting then. PMID:15376765

  3. Evidence for myocardial CT perfusion imaging in the diagnosis of hemodynamically significant coronary artery disease

    PubMed Central

    2015-01-01

    This editorial discusses a recent paper published in the August issue of Radiology about the diagnostic value of myocardial computer tomography (CT) perfusion imaging in the detection of hemodynamically significant coronary stenosis when compared to single-photon emission CT (SPECT) imaging based on a secondary analysis of CORE320 study. Three aspects including high diagnostic sensitivity of CT perfusion imaging, moderate specificity of SPECT imaging and lack of use of attenuation correction in SPECT imaging have been discussed with reference to the current literature, and some suggestions have been highlighted for future studies to improve the diagnostic performance of CT perfusion and SPECT imaging in the diagnostic evaluation of coronary artery disease. PMID:25774349

  4. Myocardial perfusion scintigraphy: the evidence.

    PubMed

    Underwood, S R; Anagnostopoulos, C; Cerqueira, M; Ell, P J; Flint, E J; Harbinson, M; Kelion, A D; Al-Mohammad, A; Prvulovich, E M; Shaw, L J; Tweddel, A C

    2004-02-01

    This review summarises the evidence for the role of myocardial perfusion scintigraphy (MPS) in patients with known or suspected coronary artery disease. It is the product of a consensus conference organised by the British Cardiac Society, the British Nuclear Cardiology Society and the British Nuclear Medicine Society and is endorsed by the Royal College of Physicians of London and the Royal College of Radiologists. It was used to inform the UK National Institute of Clinical Excellence in their appraisal of MPS in patients with chest pain and myocardial infarction. MPS is a well-established, non-invasive imaging technique with a large body of evidence to support its effectiveness in the diagnosis and management of angina and myocardial infarction. It is more accurate than the exercise ECG in detecting myocardial ischaemia and it is the single most powerful technique for predicting future coronary events. The high diagnostic accuracy of MPS allows reliable risk stratification and guides the selection of patients for further interventions, such as revascularisation. This in turn allows more appropriate utilisation of resources, with the potential for both improved clinical outcomes and greater cost-effectiveness. Evidence from modelling and observational studies supports the enhanced cost-effectiveness associated with MPS use. In patients presenting with stable or acute chest pain, strategies of investigation involving MPS are more cost-effective than those not using the technique. MPS also has particular advantages over alternative techniques in the management of a number of patient subgroups, including women, the elderly and those with diabetes, and its use will have a favourable impact on cost-effectiveness in these groups. MPS is already an integral part of many clinical guidelines for the investigation and management of angina and myocardial infarction. However, the technique is underutilised in the UK, as judged by the inappropriately long waiting times and by

  5. Universal Cosmic Absolute and Modern Science

    NASA Astrophysics Data System (ADS)

    Kostro, Ludwik

    The official Sciences, especially all natural sciences, respect in their researches the principle of methodic naturalism i.e. they consider all phenomena as entirely natural and therefore in their scientific explanations they do never adduce or cite supernatural entities and forces. The purpose of this paper is to show that Modern Science has its own self-existent, self-acting, and self-sufficient Natural All-in Being or Omni-Being i.e. the entire Nature as a Whole that justifies the scientific methodic naturalism. Since this Natural All-in Being is one and only It should be considered as the own scientifically justified Natural Absolute of Science and should be called, in my opinion, the Universal Cosmic Absolute of Modern Science. It will be also shown that the Universal Cosmic Absolute is ontologically enormously stratified and is in its ultimate i.e. in its most fundamental stratum trans-reistic and trans-personal. It means that in its basic stratum. It is neither a Thing or a Person although It contains in Itself all things and persons with all other sentient and conscious individuals as well, On the turn of the 20th century the Science has begun to look for a theory of everything, for a final theory, for a master theory. In my opinion the natural Universal Cosmic Absolute will constitute in such a theory the radical all penetrating Ultimate Basic Reality and will substitute step by step the traditional supernatural personal Absolute.

  6. Absolute Measurements of Radiation Damage in Nanometer Thick Films

    PubMed Central

    Alizadeh, Elahe; Sanche, Léon

    2013-01-01

    We address the problem of absolute measurements of radiation damage in films of nanometer thicknesses. Thin films of DNA (~ 2–160nm) are deposited onto glass substrates and irradiated with varying doses of 1.5 keV X-rays under dry N2 at atmospheric pressure and room temperature. For each different thickness, the damage is assessed by measuring the loss of the supercoiled configuration as a function of incident photon fluence. From the exposure curves, the G-values are deduced, assuming that X-ray photons interacting with DNA, deposit all of their energy in the film. The results show that the G-value (i.e., damage per unit of deposited energy) increases with film thickness and reaches a plateau at 30±5 nm. This thickness dependence provides a correction factor to estimate the actual G-value for films with thicknesses below 30nm thickness. Thus, the absolute values of damage can be compared with that of films of any thickness under different experimental conditions. PMID:22562941

  7. Apicoaortic conduit and cerebral perfusion in mixed aortic valve disease: a computational analysis

    PubMed Central

    Fragomeni, Gionata; Rossi, Michele; Condemi, Francesca; Mazzitelli, Rosario; Serraino, Giuseppe Filiberto; Renzulli, Attilio

    2013-01-01

    OBJECTIVES The revival of the apicoaortic conduit has attracted new interest in this alternative treatment for severe aortic stenosis unsuitable for conventional valve replacement. However, doubts still exist about the perfusion of the epiaortic vessels after apicoaortic conduit implantation, especially when severe aortic stenosis is associated with aortic valve insufficiency. The aim of the study was to evaluate the perfusion of the epiaortic vessels (innominate artery, left carodit artery and left subclavian artery) in cases of mixed aortic valve disease before and after apicoaortic conduit implantation. METHODS Starting from the data of a real patient with severe aortic stenosis and mild aortic insufficiency who underwent apicoaortic conduit implantation, we created a computational model where severe aortic valve stenosis was associated with different grades of aortic insufficiency (mild, medium and moderate). RESULTS A total of six combinations were analysed. In all simulations, the more severe the concomitant aortic insufficiency, the more the flow through the epiaortic vessels was diminished. After apicoaortic conduit implantation, there was an absolute augmentation of the median output in each epiaortic vessel compared with the same combination of mixed aortic valve disease before implantation. Interestingly, retrograde flow from the conduit in the descending aorta was minimal and did not contribute to the improved output of the epiaortic vessels. CONCLUSIONS The computational analysis suggested a protective effect, rather than steal phenomenon, of the apicoaortic conduit towards the cerebral perfusion, even in cases of mixed aortic valve disease. PMID:23962852

  8. Effects of laser acupuncture on blood perfusion rate

    NASA Astrophysics Data System (ADS)

    Wang, Xian-ju; Zeng, Chang-chun; Liu, Han-ping; Liu, Song-hao; Liu, Liang-gang

    2006-09-01

    Based on Pennes equation, the influences of the intensity and the impulse frequency of laser acupuncture on the point tissues' blood flow perfusion rate are discussed. We find that the blood perfusion rate of point tissue increases with the intensity of laser acupuncture increasing. After impulse laser acupuncture the point tissue blood perfusion rate increase little, but after continuum laser acupuncture the point tissues blood perfusion rate increase much.

  9. Molecular iodine absolute frequencies. Final report

    SciTech Connect

    Sansonetti, C.J.

    1990-06-25

    Fifty specified lines of {sup 127}I{sub 2} were studied by Doppler-free frequency modulation spectroscopy. For each line the classification of the molecular transition was determined, hyperfine components were identified, and one well-resolved component was selected for precise determination of its absolute frequency. In 3 cases, a nearby alternate line was selected for measurement because no well-resolved component was found for the specified line. Absolute frequency determinations were made with an estimated uncertainty of 1.1 MHz by locking a dye laser to the selected hyperfine component and measuring its wave number with a high-precision Fabry-Perot wavemeter. For each line results of the absolute measurement, the line classification, and a Doppler-free spectrum are given.

  10. Stimulus probability effects in absolute identification.

    PubMed

    Kent, Christopher; Lamberts, Koen

    2016-05-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of presentation probability on both proportion correct and response times. The effects were moderated by the ubiquitous stimulus position effect. The accuracy and response time data were predicted by an exemplar-based model of perceptual cognition (Kent & Lamberts, 2005). The bow in discriminability was also attenuated when presentation probability for middle items was relatively high, an effect that will constrain future model development. The study provides evidence for item-specific learning in absolute identification. Implications for other theories of absolute identification are discussed. (PsycINFO Database Record PMID:26478959

  11. Absolute calibration in vivo measurement systems

    SciTech Connect

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs.

  12. Correction of NIM-3A absolute gravimeter for self-attraction effect

    NASA Astrophysics Data System (ADS)

    Li, Chunjian; Xu, Jin-yi; Feng, Jin-yang; SU, Duo-wu; Wu, Shu-qing

    2015-02-01

    The mass of free-fall absolute gravimeter can produce vertical gravitational attraction to the free-falling test body during the measurement of acceleration due to gravity. The vertical gravitational attraction can cause an artificial deviation to the measured value of gravitational acceleration. This paper describes the operating principle of a free-fall absolute gravimeter and the method used to determine the reference height of a gravimeter. It also describes the physical structure of NIM-3A absolute gravimeter lately developed by National Institute of Metrology (China), and studies the correction of gravimeter for Self-attraction effect.

  13. Precise Measurement of the Absolute Fluorescence Yield

    NASA Astrophysics Data System (ADS)

    Ave, M.; Bohacova, M.; Daumiller, K.; Di Carlo, P.; di Giulio, C.; San Luis, P. Facal; Gonzales, D.; Hojvat, C.; Hörandel, J. R.; Hrabovsky, M.; Iarlori, M.; Keilhauer, B.; Klages, H.; Kleifges, M.; Kuehn, F.; Monasor, M.; Nozka, L.; Palatka, M.; Petrera, S.; Privitera, P.; Ridky, J.; Rizi, V.; D'Orfeuil, B. Rouille; Salamida, F.; Schovanek, P.; Smida, R.; Spinka, H.; Ulrich, A.; Verzi, V.; Williams, C.

    2011-09-01

    We present preliminary results of the absolute yield of fluorescence emission in atmospheric gases. Measurements were performed at the Fermilab Test Beam Facility with a variety of beam particles and gases. Absolute calibration of the fluorescence yield to 5% level was achieved by comparison with two known light sources--the Cherenkov light emitted by the beam particles, and a calibrated nitrogen laser. The uncertainty of the energy scale of current Ultra-High Energy Cosmic Rays experiments will be significantly improved by the AIRFLY measurement.

  14. Neutron activation analysis of certified samples by the absolute method

    NASA Astrophysics Data System (ADS)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  15. Parametric myocardial perfusion PET imaging using physiological clustering

    NASA Astrophysics Data System (ADS)

    Mohy-ud-Din, Hassan; Karakatsanis, Nikolaos A.; Lodge, Martin A.; Tang, Jing; Rahmim, Arman

    2014-03-01

    We propose a novel framework of robust kinetic parameter estimation applied to absolute ow quanti cation in dynamic PET imaging. Kinetic parameter estimation is formulated as a nonlinear least squares with spatial constraints problem (NLLS-SC) where the spatial constraints are computed from a physiologically driven clustering of dynamic images, and used to reduce noise contamination. An ideal clustering of dynamic images depends on the underlying physiology of functional regions, and in turn, physiological processes are quanti ed by kinetic parameter estimation. Physiologically driven clustering of dynamic images is performed using a clustering algorithm (e.g. K-means, Spectral Clustering etc) with Kinetic modeling in an iterative handshaking fashion. This gives a map of labels where each functionally homogenous cluster is represented by mean kinetics (cluster centroid). Parametric images are acquired by solving the NLLS-SC problem for each voxel which penalizes spatial variations from its mean kinetics. This substantially reduces noise in the estimation process for each voxel by utilizing kinetic information from physiologically similar voxels (cluster members). Resolution degradation is also substantially minimized as no spatial smoothing between heterogeneous functional regions is performed. The proposed framework is shown to improve the quantitative accuracy of Myocardial Perfusion (MP) PET imaging, and in turn, has the long-term potential to enhance capabilities of MP PET in the detection, staging and management of coronary artery disease.

  16. Quantification of myocardial perfusion using CMR with a radial data acquisition: comparison with a dual-bolus method

    PubMed Central

    2010-01-01

    Background Quantitative estimates of myocardial perfusion generally require accurate measurement of the arterial input function (AIF). The saturation of signal intensity in the blood that occurs with most doses of contrast agent makes obtaining an accurate AIF challenging. This work seeks to evaluate the performance of a method that uses a radial k-space perfusion sequence and multiple saturation recovery times (SRT) to quantify myocardial perfusion with cardiovascular magnetic resonance (CMR). Methods Perfusion CMR was performed at 3 Tesla with a saturation recovery radial turboFLASH sequence with 72 rays. Fourteen subjects were given a low dose (0.004 mmol/kg) of dilute (1/5 concentration) contrast agent (Gd-BOPTA) and then a higher non-dilute dose of the same volume (0.02 mmol/kg). AIFs were calculated from the blood signal in three sub-images with differing effective saturation recovery times. The full and sub-images were reconstructed iteratively with a total variation constraint. The images from the full 72 ray data were processed to obtain six tissue enhancement curves in two slices of the left ventricle in each subject. A 2-compartment model was used to determine absolute flows Results The proposed multi-SRT method resulted in AIFs that were similar to those obtained with the dual-bolus method. Myocardial blood flow (MBF) estimates from the dual-bolus and the multi-SRT methods were related by MBFmulti-SRT = 0.85MBFdual-bolus + 0.18 (r = 0.91). Conclusions The multi-SRT method, which uses a radial k-space perfusion sequence, can be used to obtain an accurate AIF and thus quantify myocardial perfusion for doses of contrast agent that result in a relatively saturated AIF. PMID:20653961

  17. Absolute GNSS Antenna Calibration at the National Geodetic Survey

    NASA Astrophysics Data System (ADS)

    Mader, G.; Bilich, A.; Geoghegan, C.

    2012-04-01

    Geodetic GNSS applications routinely demand millimeter precision and extremely high levels of accuracy. To achieve these accuracies, measurement and instrument biases at the centimeter to millimeter level must be understood. One of these biases is the antenna phase center, the apparent point of signal reception for a GNSS antenna. It has been well established that phase center patterns differ between antenna models and manufacturers; additional research suggests that the addition of a radome or the choice of antenna mount can significantly alter those a priori phase center patterns. For the more demanding GNSS positioning applications and especially in cases of mixed-antenna networks, it is all the more important to know antenna phase center variations as a function of both elevation and azimuth in the antenna reference frame and incorporate these models into analysis software. To help meet the needs of the high-precision GNSS community, the National Geodetic Survey (NGS) now operates an absolute antenna calibration facility. Located in Corbin, Virginia, this facility uses field measurements and actual GNSS satellite signals to quantitatively determine the carrier phase advance/delay introduced by the antenna element. The NGS facility was built to serve traditional NGS constituents such as the surveying and geodesy communities, however calibration services are open and available to all GNSS users as the calibration schedule permits. All phase center patterns computed by this facility will be publicly available and disseminated in both the ANTEX and NGS formats. We describe the NGS calibration facility, and discuss the observation models and strategy currently used to generate NGS absolute calibrations. We demonstrate that NGS absolute phase center variation (PCV) patterns are consistent with published values determined by other absolute antenna calibration facilities, and outline future planned refinements to the system.

  18. Gradient-enhanced FAWSETS perfusion measurements

    NASA Astrophysics Data System (ADS)

    Marro, Kenneth I.; Lee, Donghoon; Hyyti, Outi M.

    2005-08-01

    This work describes the use of custom-built gradients to enhance skeletal muscle perfusion measurements acquired with a previously described arterial spin labeling technique known as FAWSETS (flow-driven arterial water stimulation with elimination of tissue signal). Custom-built gradients provide active control of the static magnetic field gradient on which FAWSETS relies for labeling. This allows selective, 180° modulations of the phase of the perfusion component of the signal. Phase cycling can then be implemented to eliminate all extraneous components leaving a signal that exclusively reflects capillary-level perfusion. Gradient-enhancement substantially reduces acquisition time and eliminates the need to acquire an ischemic signal to quantify perfusion. This removes critical obstacles to application of FAWSETS in organs other than skeletal muscle and makes the measurements more desirable for clinical environments. The basic physical principles of gradient-enhancement are demonstrated in flow phantom experiments and in vivo utility is demonstrated in rat hind limb during stimulated exercise.

  19. Urate synthesis in the perfused chick liver

    PubMed Central

    Barratt, Eileen; Buttery, Peter J.; Boorman, K. Neil

    1974-01-01

    Urate synthesis was studied in a perfused chicken liver preparation. The perfused liver had an ATP/ADP ratio of 0.29±0.05(6) compared with 0.34±0.07(10) in liver obtained from chicks under ether anaesthesia. Lactate/pyruvate ratios were 9.4±1.7(5) in the perfused liver and 14.8±1.8(5) in the rapidly sampled liver. Urate synthesis was only marginally stimulated by glycine, glutamine, aspartic acid or NH4Cl, but significant increases were observed with phosphoribosyl pyrophosphate, aminoimidazolecarboxylic acid riboside, inosine, inosinic acid and xanthine. Urate synthesis from glycine, glutamine, NH4Cl, asparagine, alanine, histidine and a mixture of 21 amino acids was obtained on inclusion of insulin in the perfusion medium. Evidence for the inclusion of the carbon of histidine into uric acid was obtained. Aspects of the energy consumption associated with the conversion of excess of amino acid into uric acid are considered. PMID:4462579

  20. Automated sonographic evaluation of testicular perfusion

    NASA Astrophysics Data System (ADS)

    Thierman, Jonathan S.; Clement, Gregory T.; Kalish, Leslie A.; O'Kane, Patrick L.; Frauscher, Ferdinand; Paltiel, Harriet J.

    2006-07-01

    Contrast-enhanced ultrasound (US) imaging is potentially applicable to the investigation of vascular disorders of the testis. We investigated the ability of two automated computer algorithms to analyse contrast-enhanced pulse inversion US data in a rabbit model of unilateral testicular ischaemia and to correctly determine relative testicular perfusion: nonlinear curve fitting of the US backscatter intensity as a function of time; and spectral analysis of the intensity time trace. We compared (i) five metrics based on the algorithmic data to testicular perfusion ratios obtained with radiolabelled microspheres, a reference standard; (ii) qualitative assessment of the US images by two independent readers blinded to the side of the experimental and control testes to the radiolabelled microsphere perfusion ratios; and (iii) results of the algorithmically-derived metrics to the qualitative assessments of the two readers. For the curve fit method, the algorithmically-derived metrics agreed with the reference standard in 54% to 68% of all cases. For the spectral method, the results agreed in 70% of all cases. The two readers agreed with the reference standard in 40% and 35% of all cases, respectively. These results suggest that automated methods of analysis may provide useful information in the assessment of testicular perfusion.

  1. Asynchronicity of Facial Blood Perfusion in Migraine

    PubMed Central

    Zaproudina, Nina; Teplov, Victor; Nippolainen, Ervin; Lipponen, Jukka A.; Kamshilin, Alexei A.; Närhi, Matti; Karjalainen, Pasi A.; Giniatullin, Rashid

    2013-01-01

    Asymmetrical changes in blood perfusion and asynchronous blood supply to head tissues likely contribute to migraine pathophysiology. Imaging was widely used in order to understand hemodynamic variations in migraine. However, mapping of blood pulsations in the face of migraineurs has not been performed so far. We used the Blood Pulsation Imaging (BPI) technique, which was recently developed in our group, to establish whether 2D-imaging of blood pulsations parameters can reveal new biomarkers of migraine. BPI characteristics were measured in migraineurs during the attack-free interval and compared to healthy subjects with and without a family history of migraine. We found a novel phenomenon of transverse waves of facial blood perfusion in migraineurs in contrast to healthy subjects who showed synchronous blood delivery to both sides of the face. Moreover, the amplitude of blood pulsations was symmetrically distributed over the face of healthy subjects, but asymmetrically in migraineurs and subjects with a family history of migraine. In the migraine patients we found a remarkable correlation between the side of unilateral headache and the direction of the blood perfusion wave. Our data suggest that migraine is associated with lateralization of blood perfusion and asynchronous blood pulsations in the facial area, which could be due to essential dysfunction of the autonomic vascular control in the face. These findings may further enhance our understanding of migraine pathophysiology and suggest new easily available biomarkers of this pathology. PMID:24324592

  2. Simplified prototyping of perfusable polystyrene microfluidics

    PubMed Central

    Tran, Reginald; Ahn, Byungwook; R. Myers, David; Qiu, Yongzhi; Sakurai, Yumiko; Moot, Robert; Mihevc, Emma; Trent Spencer, H.; Doering, Christopher; A. Lam, Wilbur

    2014-01-01

    Cell culture in microfluidic systems has primarily been conducted in devices comprised of polydimethylsiloxane (PDMS) or other elastomers. As polystyrene (PS) is the most characterized and commonly used substrate material for cell culture, microfluidic cell culture would ideally be conducted in PS-based microsystems that also enable tight control of perfusion and hydrodynamic conditions, which are especially important for culture of vascular cell types. Here, we report a simple method to prototype perfusable PS microfluidics for endothelial cell culture under flow that can be fabricated using standard lithography and wet laboratory equipment to enable stable perfusion at shear stresses up to 300 dyn/cm2 and pumping pressures up to 26 kPa for at least 100 h. This technique can also be extended to fabricate perfusable hybrid PS-PDMS microfluidics of which one application is for increased efficiency of viral transduction in non-adherent suspension cells by leveraging the high surface area to volume ratio of microfluidics and adhesion molecules that are optimized for PS substrates. These biologically compatible microfluidic devices can be made more accessible to biological-based laboratories through the outsourcing of lithography to various available microfluidic foundries. PMID:25379106

  3. Nuclear cardiology: Myocardial perfusion and function

    SciTech Connect

    Seldin, D.W. )

    1991-08-01

    Myocardial perfusion studies continue to be a major focus of research, with new investigations of the relationship of exercise-redistribution thallium imaging to diagnosis, prognosis, and case management. The redistribution phenomenon, which seemed to be fairly well understood a few years ago, is now recognized to be much more complex than originally thought, and various strategies have been proposed to clarify the meaning of persistent defects. Pharmacologic intervention with dipyridamole and adenosine has become available as an alternative to exercise, and comparisons with exercise imaging and catheterization results have been described. Thallium itself is no longer the sole single-photon perfusion radiopharmaceutical; two new technetium agents are now widely available. In addition to perfusion studies, advances in the study of ventricular function have been made, including reports of studies performed in conjunction with technetium perfusion studies, new insights into cardiac physiology, and the prognostic and case-management information that function studies provide. Finally, work has continued with monoclonal antibodies for the identification of areas of myocyte necrosis. 41 references.

  4. Whole-Brain CT Perfusion to Quantify Acute Ischemic Penumbra and Core.

    PubMed

    Lin, Longting; Bivard, Andrew; Krishnamurthy, Venkatesh; Levi, Christopher R; Parsons, Mark W

    2016-06-01

    Purpose To validate the use of perfusion computed tomography (CT) with whole-brain coverage to measure the ischemic penumbra and core and to compare its performance to that of limited-coverage perfusion CT. Materials and Methods Institutional ethics committee approval and informed consent were obtained. Patients (n = 296) who underwent 320-detector CT perfusion within 6 hours of the onset of ischemic stroke were studied. First, the ischemic volume at CT perfusion was compared with the penumbra and core reference values at magnetic resonance (MR) imaging to derive CT perfusion penumbra and core thresholds. Second, the thresholds were tested in a different group of patients to predict the final infarction at diffusion-weighted imaging 24 hours after CT perfusion. Third, the change in ischemic volume delineated by the optimal penumbra and core threshold was determined as the brain coverage was gradually reduced from 160 mm to 20 mm. The Wilcoxon signed-rank test, concordance correlation coefficient (CCC), and analysis of variance were used for the first, second, and third steps, respectively. Results CT perfusion at penumbra and core thresholds resulted in the least volumetric difference from MR imaging reference values with delay times greater than 3 seconds and delay-corrected cerebral blood flow of less than 30% (P = .34 and .33, respectively). When the thresholds were applied to the new group of patients, prediction of the final infarction was allowed with delay times greater than 3 seconds in patients with no recanalization of the occluded artery (CCC, 0.96 [95% confidence interval: 0.92, 0.98]) and with delay-corrected cerebral blood flow less than 30% in patients with complete recanalization (CCC, 0.91 [95% confidence interval: 0.83, 0.95]). However, the ischemic volume with a delay time greater than 3 seconds was underestimated when the brain coverage was reduced to 80 mm (P = .04) and the core volume measured as cerebral blood flow less than 30% was

  5. Comparing Normothermic Machine Perfusion Preservation With Different Perfusates on Porcine Livers From Donors After Circulatory Death.

    PubMed

    Liu, Q; Nassar, A; Farias, K; Buccini, L; Mangino, M J; Baldwin, W; Bennett, A; O'Rourke, C; Iuppa, G; Soliman, B G; Urcuyo-Llanes, D; Okamoto, T; Uso, T D; Fung, J; Abu-Elmagd, K; Miller, C; Quintini, C

    2016-03-01

    The utilization of normothermic machine perfusion (NMP) may be an effective strategy to resuscitate livers from donation after circulatory death (DCD). There is no consensus regarding the efficacy of different perfusates on graft and bile duct viability. The aim of this study was to compare, in an NMP porcine DCD model, the preservation potential of three different perfusates. Twenty porcine livers with 60 min of warm ischemia were separated into four preservation groups: cold storage (CS), NMP with Steen solution (Steen; XVIVO Perfusion Inc., Denver, CO), Steen plus red blood cells (RBCs), or whole blood (WB). All livers were preserved for 10 h and reperfused to simulate transplantation for 24 h. During preservation, the NMP with Steen group presented the highest hepatocellular injury. At reperfusion, the CS group had the lowest bile production and the worst hepatocellular injury compared with all other groups, followed by NMP with Steen; the Steen plus RBC and WB groups presented the best functional and hepatocellular injury outcomes, with WB livers showing lower aspartate aminotransferase release and a trend toward better results for most parameters. Based on our results, a perfusate that contains an oxygen carrier is most effective in a model of NMP porcine DCD livers compared with Steen solution. Specifically, WB-perfused livers showed a trend toward better outcomes compared with Steen plus RBCs. PMID:26663737

  6. On the convective-absolute nature of river bedform instabilities

    NASA Astrophysics Data System (ADS)

    Vesipa, Riccardo; Camporeale, Carlo; Ridolfi, Luca; Chomaz, Jean Marc

    2014-12-01

    River dunes and antidunes are induced by the morphological instability of stream-sediment boundary. Such bedforms raise a number of subtle theoretical questions and are crucial for many engineering and environmental problems. Despite their importance, the absolute/convective nature of the instability has never been addressed. The present work fills this gap as we demonstrate, by the cusp map method, that dune instability is convective for all values of the physical control parameters, while the antidune instability exhibits both behaviors. These theoretical predictions explain some previous experimental and numerical observations and are important to correctly plan flume experiments, numerical simulations, paleo-hydraulic reconstructions, and river works.

  7. Prelaunch absolute radiometric calibration of LANDSAT-4 protoflight Thematic Mapper

    NASA Technical Reports Server (NTRS)

    Barker, J. L.; Ball, D. L.; Leung, K. C.; Walker, J. A.

    1984-01-01

    Results are summarized and analyzed from several prelaunch tests with a 122 cm integrating sphere used as part of the absolute radiometric calibration experiments for the protoflight TM sensor carried on the LANDSAT-4 satellite. The calibration procedure is presented and the radiometric sensitivity of the TM is assessed. The internal calibrator and dynamic range after calibration are considered. Tables show dynamic range after ground processing, spectral radiance to digital number and digital number to spectral radiance values for TM bands 1, 2, 3, 4, 5, 7 and for channel 4 of band 6.

  8. Testing and evaluation of thermal cameras for absolute temperature measurement

    NASA Astrophysics Data System (ADS)

    Chrzanowski, Krzysztof; Fischer, Joachim; Matyszkiel, Robert

    2000-09-01

    The accuracy of temperature measurement is the most important criterion for the evaluation of thermal cameras used in applications requiring absolute temperature measurement. All the main international metrological organizations currently propose a parameter called uncertainty as a measure of measurement accuracy. We propose a set of parameters for the characterization of thermal measurement cameras. It is shown that if these parameters are known, then it is possible to determine the uncertainty of temperature measurement due to only the internal errors of these cameras. Values of this uncertainty can be used as an objective criterion for comparisons of different thermal measurement cameras.

  9. Absolute partial photoionization cross sections of ozone.

    SciTech Connect

    Berkowitz, J.; Chemistry

    2008-04-01

    Despite the current concerns about ozone, absolute partial photoionization cross sections for this molecule in the vacuum ultraviolet (valence) region have been unavailable. By eclectic re-evaluation of old/new data and plausible assumptions, such cross sections have been assembled to fill this void.

  10. Increasing Capacity: Practice Effects in Absolute Identification

    ERIC Educational Resources Information Center

    Dodds, Pennie; Donkin, Christopher; Brown, Scott D.; Heathcote, Andrew

    2011-01-01

    In most of the long history of the study of absolute identification--since Miller's (1956) seminal article--a severe limit on performance has been observed, and this limit has resisted improvement even by extensive practice. In a startling result, Rouder, Morey, Cowan, and Pfaltz (2004) found substantially improved performance with practice in the…

  11. On Relative and Absolute Conviction in Mathematics

    ERIC Educational Resources Information Center

    Weber, Keith; Mejia-Ramos, Juan Pablo

    2015-01-01

    Conviction is a central construct in mathematics education research on justification and proof. In this paper, we claim that it is important to distinguish between absolute conviction and relative conviction. We argue that researchers in mathematics education frequently have not done so and this has lead to researchers making unwarranted claims…

  12. Absolute Points for Multiple Assignment Problems

    ERIC Educational Resources Information Center

    Adlakha, V.; Kowalski, K.

    2006-01-01

    An algorithm is presented to solve multiple assignment problems in which a cost is incurred only when an assignment is made at a given cell. The proposed method recursively searches for single/group absolute points to identify cells that must be loaded in any optimal solution. Unlike other methods, the first solution is the optimal solution. The…

  13. Nonequilibrium equalities in absolutely irreversible processes

    NASA Astrophysics Data System (ADS)

    Murashita, Yuto; Funo, Ken; Ueda, Masahito

    2015-03-01

    Nonequilibrium equalities have attracted considerable attention in the context of statistical mechanics and information thermodynamics. Integral nonequilibrium equalities reveal an ensemble property of the entropy production σ as = 1 . Although nonequilibrium equalities apply to rather general nonequilibrium situations, they break down in absolutely irreversible processes, where the forward-path probability vanishes and the entropy production diverges. We identify the mathematical origins of this inapplicability as the singularity of probability measure. As a result, we generalize conventional integral nonequilibrium equalities to absolutely irreversible processes as = 1 -λS , where λS is the probability of the singular part defined based on Lebesgue's decomposition theorem. The acquired equality contains two physical quantities related to irreversibility: σ characterizing ordinary irreversibility and λS describing absolute irreversibility. An inequality derived from the obtained equality demonstrates the absolute irreversibility leads to the fundamental lower bound on the entropy production. We demonstrate the validity of the obtained equality for a simple model.

  14. Stimulus Probability Effects in Absolute Identification

    ERIC Educational Resources Information Center

    Kent, Christopher; Lamberts, Koen

    2016-01-01

    This study investigated the effect of stimulus presentation probability on accuracy and response times in an absolute identification task. Three schedules of presentation were used to investigate the interaction between presentation probability and stimulus position within the set. Data from individual participants indicated strong effects of…

  15. Precision absolute positional measurement of laser beams.

    PubMed

    Fitzsimons, Ewan D; Bogenstahl, Johanna; Hough, James; Killow, Christian J; Perreur-Lloyd, Michael; Robertson, David I; Ward, Henry

    2013-04-20

    We describe an instrument which, coupled with a suitable coordinate measuring machine, facilitates the absolute measurement within the machine frame of the propagation direction of a millimeter-scale laser beam to an accuracy of around ±4 μm in position and ±20 μrad in angle. PMID:23669658

  16. Absolute cross section for recoil detection of deuterium

    NASA Astrophysics Data System (ADS)

    Besenbacher, F.; Stensgaard, I.; Vase, P.

    1986-04-01

    The D( 4He, D) 4He cross section used for recoil detection of deuterium (D) has been calibrated on an absolute scale against the cross section of the D( 3He, α)p nuclear reaction which is often used for D profiling. For 4He energies ranging from 0.8 to ~1.8 MeV. the D( 4He, D) 4He cross section varies only slightly with incident energy and recoil angle θ (for 0° ⩽ 8 ⩽ 35°) and has a value of ~ 500 mb/sr which is significantly higher than the ~ 65 mb/sr c.m.s. cross section of the D( 3He, α)p nuclear reaction. For 4He energies ranging from ~ 1.9 to ~ 2.3 MeV, the D( 4He,D) 4He cross section exhibits a fairly narrow resonance peak (fwhm ~ 70 keV), with a maximum value (for θ = 0°) of ~ 8.5 b/sr, corresponding to a 4He energy of ~ 2130 keV. The large values of the cross section in connection with the described energy dependence makes the use of forward-recoil detection of D attractive for many purposes, e.g., D Jepth profiling (with an extreme gain in sensitivity), absolute concentration or coverage measurements, and lattice-location experiments by transmission channeling.

  17. Absolute uniqueness of phase retrieval with random illumination

    NASA Astrophysics Data System (ADS)

    Fannjiang, Albert

    2012-07-01

    Random illumination is proposed to enforce absolute uniqueness and resolve all types of ambiguity, trivial or nontrivial, in phase retrieval. Almost sure irreducibility is proved for any complex-valued object whose support set has rank ⩾ 2. While the new irreducibility result can be viewed as a probabilistic version of the classical result by Bruck, Sodin and Hayes, it provides a novel perspective and an effective method for phase retrieval. In particular, almost sure uniqueness, up to a global phase, is proved for complex-valued objects under general two-point conditions. Under a tight sector constraint absolute uniqueness is proved to hold with probability exponentially close to unity as the object sparsity increases. Under a magnitude constraint with random amplitude illumination, uniqueness modulo global phase is proved to hold with probability exponentially close to unity as object sparsity increases. For general complex-valued objects without any constraint, almost sure uniqueness up to global phase is established with two sets of Fourier magnitude data under two independent illuminations. Numerical experiments suggest that random illumination essentially alleviates most, if not all, numerical problems commonly associated with the standard phasing algorithms.

  18. Iterative blind deconvolution in magnetic resonance brain perfusion imaging.

    PubMed

    Grüner, Renate; Taxt, Torfinn

    2006-04-01

    In first pass magnetic resonance brain perfusion imaging, arterial input functions are used in the deconvolution of the observed contrast concentrations to obtain quantitative hemodynamic parameters. Ideally, arterial input functions should be measured in each imaged voxel to eliminate the effects of delay and dispersion of the contrast agent from the injection site. An approach based on iterative blind deconvolution with the Richardson-Lucy algorithm is proposed for the simultaneous estimation of voxel-specific arterial input functions and voxel-specific tissue residue functions. An extended contrast concentration model was used to separate the first pass bolus from additional recirculation and leakage signals. The extended model was evaluated using in vivo data. Computer simulations examined the feasibility of iterative blind deconvolution in perfusion imaging. Preliminary in vivo results from a patient with fibromuscular dysplasia showed territories with delayed/dispersed arterial input functions that coincided with the location of territories supplied by collateral circulation as described from the complete radiologic examination. Higher flow values and shorter mean transit times compared to conventional methods were obtained in these areas, suggesting that the effects of dispersion were minimized. The in vivo estimated arterial input functions visualized the patient's blood supply patterns as a function of time. PMID:16526016

  19. Recent developments and future prospects of SPECT myocardial perfusion imaging.

    PubMed

    Zaman, Maseeh Uz; Hashmi, Ibrahim; Fatima, Nosheen

    2010-10-01

    Myocardial perfusion SPECT imaging is the most commonly performed functional imaging for assessment of coronary artery disease. High diagnostic accuracy and incremental prognostic value are the major benefits while suboptimal spatial resolution and significant radiation exposure are the main limitations. Its ability to detect hemodynamic significance of lesions seen on multidetector CT angiogram (MDCTA) has paved the path for a successful marriage between anatomical and functional imaging modalities in the form of hybrid SPECT/MDCTA system. In recent years, there have been enormous efforts by industry and academia to develop new SPECT imaging systems with better sensitivity, resolution, compact design and new reconstruction algorithms with ability to improve image quality and resolution. Furthermore, expected arrival of Tc-99m-labeled deoxyglucose in next few years would further strengthen the role of SPECT in imaging hibernating myocardium. In view of these developments, it seems that SPECT would enjoy its pivotal role in spite of major threat to be replaced by fluorine-18-labeled positron emission tomography perfusion and glucose metabolism imaging agents. PMID:20652774

  20. Bayesian hemodynamic parameter estimation by bolus tracking perfusion weighted imaging.

    PubMed

    Boutelier, Timothé; Kudo, Koshuke; Pautot, Fabrice; Sasaki, Makoto

    2012-07-01

    A delay-insensitive probabilistic method for estimating hemodynamic parameters, delays, theoretical residue functions, and concentration time curves by computed tomography (CT) and magnetic resonance (MR) perfusion weighted imaging is presented. Only a mild stationarity hypothesis is made beyond the standard perfusion model. New microvascular parameters with simple hemodynamic interpretation are naturally introduced. Simulations on standard digital phantoms show that the method outperforms the oscillating singular value decomposition (oSVD) method in terms of goodness-of-fit, linearity, statistical and systematic errors on all parameters, especially at low signal-to-noise ratios (SNRs). Delay is always estimated sharply with user-supplied resolution and is purely arterial, by contrast to oSVD time-to-maximum TMAX that is very noisy and biased by mean transit time (MTT), blood volume, and SNR. Residue functions and signals estimates do not suffer overfitting anymore. One CT acute stroke case confirms simulation results and highlights the ability of the method to reliably estimate MTT when SNR is low. Delays look promising for delineating the arterial occlusion territory and collateral circulation. PMID:22410325

  1. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    PubMed Central

    Handayani, A.; Dijkstra, H.; Prakken, N. H. J.; Slart, R. H. J. A.; Oudkerk, M.; Van Ooijen, P. M. A.; Vliegenthart, R.; Sijens, P. E.

    2016-01-01

    Technological advances in magnetic resonance imaging (MRI) and computed tomography (CT), including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET). This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD), as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings. PMID:27088083

  2. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation.

    PubMed

    Pelgrim, G J; Handayani, A; Dijkstra, H; Prakken, N H J; Slart, R H J A; Oudkerk, M; Van Ooijen, P M A; Vliegenthart, R; Sijens, P E

    2016-01-01

    Technological advances in magnetic resonance imaging (MRI) and computed tomography (CT), including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET). This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD), as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings. PMID:27088083

  3. Preliminary Study of Open Quotient in an Ex-Vivo Perfused Human Larynx Model

    PubMed Central

    Mendelsohn, Abie H.; Zhang, Zhaoyan; Luegmair, Georg; Orestes, Michael; Berke, Gerald S.

    2016-01-01

    Importance Scientific understanding human voice production to date is a product of indirect investigations including animal models, cadaveric tissue study, or computational modeling. Due to its invasive nature, direct experimentation of human voice production has previously not been possible. The feasibility of an ex-vivo perfused human phonatory model has recently allowed systematic investigation in virtually living human larynges with parametric laryngeal muscle stimulation. Objective In this study, the relationship between adductor muscle group stimulation and the open quotient (OQ) of vocal fold vibration was investigated using an ex-vivo perfused human larynx. Design Human perfused tissue study. Setting Physiology Laboratory. Participants Human larynx is recovered from research-consented organ donors within two hours of cardiac death. Interventions, Main Outcomes and Measures Perfusion with donated human blood is re-established shortly after cardiac death. Human perfused phonation is achieved by providing subglottal airflow under graded neuromuscular electrical stimulation bilaterally to the intrinsic adductor groups and cricothyroid muscles. The phonation resulting from the graded states of neuromuscular stimulations are evaluated through high-speed vibratory imaging. OQ is derived through digital kymography and glottal area waveform analysis. Results Under constant glottal flow, step-wise increase in adductor muscle group stimulation decreased OQ. Quantitatively, OQ values reached a lower limit of 0.42. Increased stimulation above maximal muscle deformation was unable to affect OQ beyond this lower limit. Conclusions and Relevance For the first time in a neuromuscularly activated human larynx, a negative relationship between adductor muscle group stimulation and phonatory OQ was demonstrated. Further experience with the ex-vivo perfused human phonatory model will work to systematically define this causal relationship. PMID:26181642

  4. Ventilation/Perfusion Scintigraphy in Children with Post-Infectious Bronchiolitis Obliterans: A Pilot Study

    PubMed Central

    Xie, Bo-Qia; Wang, Wei; Zhang, Wen-Qian; Guo, Xin-Hua; Yang, Min-Fu; Wang, Li; He, Zuo-Xiang; Tian, Yue-Qin

    2014-01-01

    Purpose Childhood post-infectious bronchiolitis obliterans (BO) is an infrequent lung disease leading to narrowing and/or complete obliteration of small airways. Ventilation and perfusion (V/Q) scan can provide both regional and global pulmonary information. However, only few retrospective researches investigating post-infectious BO involved V/Q scan, the clinical value of this method is unknown. This preliminary prospective study was aimed to evaluate the correlation of V/Q scan with disease severity, pulmonary function test results, and prognosis in children with post-infectious BO. Methods Twenty-five post-infectious BO children (18 boys and 7 girls; mean age, 41 months) underwent V/Q scan and pulmonary function tests. Patients were followed after their inclusion. Ventilation index and perfusion index obtained from V/Q scan were used to measure pulmonary abnormalities. Spearman's rank correlation test of ventilation index and perfusion index on disease severity, lung function tests indices, and follow-up results were performed. Results The median follow-up period was 4.6 years (range, 2.2 to 5.0 years). Ventilation index and perfusion index were both correlated with disease severity (r = 0.72, p<0.01 and r = 0.73, p<0.01), but only ventilation index was related to pulmonary function tests results (all p<0.05). In addition, Spearman test yielded significant correlations between perfusion index and prognosis (r = 0.77, p<0.01), and ventilation index and prognosis (r = 0.63, p = 0.01). Conclusions For children with post-infectious BO, the present study preliminarily indicated that the degree of ventilation and perfusion abnormalities evaluated by V/Q scan may be used to assess disease severity, and may be predictive of patient's outcome. PMID:24852165

  5. Added Value of Assessing Adnexal Masses with Advanced MRI Techniques

    PubMed Central

    Thomassin-Naggara, I.; Balvay, D.; Rockall, A.; Carette, M. F.; Ballester, M.; Darai, E.; Bazot, M.

    2015-01-01

    This review will present the added value of perfusion and diffusion MR sequences to characterize adnexal masses. These two functional MR techniques are readily available in routine clinical practice. We will describe the acquisition parameters and a method of analysis to optimize their added value compared with conventional images. We will then propose a model of interpretation that combines the anatomical and morphological information from conventional MRI sequences with the functional information provided by perfusion and diffusion weighted sequences. PMID:26413542

  6. Estimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity

    PubMed Central

    Horger, Marius; Buchgeister, Markus; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Schulze, Maximilian; Tsiflikas, Ilias; Claussen, Claus D.; Heuschmid, Martin

    2010-01-01

    Objective We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. Materials and Methods An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D-Perfusion-CT. Phantom measurements were performed on a 128-slice single-source scanner in adaptive 4D-spiral-mode with bidirectional table movement and a total scan range of 69 mm over a time period of nearly 120 seconds (26 scans). Perfusion measurements were simulated for the lung, liver, and pelvis under the following conditions: lung (80 kV, 60 mAs), liver (80 kV/80 mAs and 80 kV/120 mAs), pelvis (100 kV/80 mAs and 100 kV/120 mAs). Results Depending on gender, the evaluated body region and scan protocol, an effective whole-body dose between 2.9-12.2 mSv, was determined. The radiation exposure administered to gender-specific organs like the female breast tissue (lung perfusion) or to the ovaries (pelvic perfusion) led to an increase in the female specific dose by 86% and 100% in perfusion scans of the lung and the pelvis, respectively. Conclusion Due to a significant radiation dose of 4D-perfusion-CT protocols, the responsible use of this new promising technique is mandatory. Gender- and organ-specific differences should be considered for indication and planning of tumor perfusion scans. PMID:20808699

  7. Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: comparison with hyperbolic secant.

    PubMed

    Yongbi, M N; Yang, Y; Frank, J A; Duyn, J H

    1999-12-01

    Perfusion studies based on pulsed arterial spin labeling have primarily applied hyperbolic secant (HS) pulses for spin inversion. To optimize perfusion sensitivity, it is highly desirable to implement the HS pulse with the same slice width as the width of the imaging pulse. Unfortunately, this approach causes interactions between the slice profiles and manifests as residual signal from static tissue in the resultant perfusion image. This problem is currently overcome by increasing the selective HS width relative to the imaging slice width. However, this solution increases the time for the labeled blood to reach the imaging slice (transit time), causing loss of perfusion sensitivity as a result of T(1) relaxation effects. In this study, we demonstrate that the preceding problems can be largely overcome by use of the C-shaped frequency offset corrected inversion (FOCI) pulse [Ordidge et al., Magn Reson Med 1996;36:562]. The implementation of this pulse for multislice perfusion imaging on the cerebrum is presented, showing substantial improvement in slice definition in vivo compared with the HS pulse. The sharper FOCI profile is shown to reduce the physical gap (or "safety margin") between the inversion and imaging slabs, resulting in a significant increase in perfusion signal without residual contamination from static tissue. The mean +/- SE (n = 6) gray matter perfusion-weighted signal (DeltaM/M(o)) without the application of vascular signal suppression gradients were 1.19 +/- 0. 10% (HS-flow-sensitive alternating inversion recovery [FAIR]), and 1. 51 +/- 0.11% for the FOCI-FAIR sequence. The corresponding values with vascular signal suppression were 0.64 +/- 0.14%, and 0.91 +/- 0. 08% using the HS- and FOCI-FAIR sequences, respectively. Compared with the HS-based data, the FOCI-FAIR results correspond to an average increase in perfusion signal of up to between 26%-30%. Magn Reson Med 42:1098-1105, 1999. PMID:10571931

  8. Effects of BRL 38227, sodium nitroprusside and verapamil on collateral perfusion following acute arterial occlusion in the rabbit isolated ear.

    PubMed Central

    Randall, M. D.; Griffith, T. M.

    1992-01-01

    1. We have used an isolated, buffer-perfused, rabbit ear model of acute arterial occlusion to investigate the effects of the nitrovasodilator sodium nitroprusside, the potassium channel activator BRL 38227 (the active (-)-enantiomer of cromakalim) and the calcium antagonist, verapamil, on collateral perfusion in the absence of pharmacological tone. 2. Verapamil was the most potent vasodilator (EC50 = 72.6 +/- 32.0 nM) of 5-hydroxytryptamine/histamine-induced tone in the rabbit isolated perfused ear. Sodium nitroprusside and BRL 38227 were less potent with respective EC50 values of 488 +/- 75 nM and 296 +/- 40 nM. Following inhibition of endothelium-derived relaxing factor (EDRF) synthesis, the potency of BRL 38227 was significantly (P less than 0.001) increased with an EC50 of 55.6 +/- 5.0 nM. 3. BRL 38227 at 500 nM and 3 microM induced substantial increases in collateral perfusion following arterial ligation in the absence of pharmacological tone compared to control. Furthermore 3 microM BRL 38227 completely reversed the attenuation of collateral perfusion which followed inhibition of EDRF synthesis with 100 microM NG-nitro-L-arginine methyl ester (L-NAME). 4. Sodium nitroprusside (500 nM and 3 microM) induced modest improvements in collateral perfusion in the early stages after arterial occlusion. 5. Verapamil did not influence collateral perfusion at either of the concentrations used (50 nM and 3 microM), even though it was a potent vasodilator. 6. The results of this study indicate that BRL 38227, and to a much lesser extent sodium nitroprusside, selectively improve collateral perfusion following arterial occlusion, even in the presence of effects of EDRF on acute collateralization, while verapamil has no effect.(ABSTRACT TRUNCATED AT 250 WORDS) Images Figure 1 PMID:1393264

  9. Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

    SciTech Connect

    Strydhorst, Jared H. Ruddy, Terrence D.; Wells, R. Glenn

    2015-04-15

    Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with {sup 99m}Tc and {sup 201}Tl single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with {sup 99m}Tc-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with {sup 201}Tl and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolute uptake of {sup 99m}Tc in the heart was also quantified with and without attenuation correction. Results: For {sup 99m}Tc imaging, relative segmental perfusion changed by up to +2.1%/−1.8% as a result of attenuation correction. Relative changes of +3.6%/−1.0% were observed for the {sup 201}Tl images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected {sup 99m}Tc scans, and 3.6% and 4.3%, respectively, for the {sup 201}Tl scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake.

  10. Combined Use of Absolute and Differential Seismic Arrival Time Data to Improve Absolute Event Location

    NASA Astrophysics Data System (ADS)

    Myers, S.; Johannesson, G.

    2012-12-01

    Arrival time measurements based on waveform cross correlation are becoming more common as advanced signal processing methods are applied to seismic data archives and real-time data streams. Waveform correlation can precisely measure the time difference between the arrival of two phases, and differential time data can be used to constrain relative location of events. Absolute locations are needed for many applications, which generally requires the use of absolute time data. Current methods for measuring absolute time data are approximately two orders of magnitude less precise than differential time measurements. To exploit the strengths of both absolute and differential time data, we extend our multiple-event location method Bayesloc, which previously used absolute time data only, to include the use of differential time measurements that are based on waveform cross correlation. Fundamentally, Bayesloc is a formulation of the joint probability over all parameters comprising the multiple event location system. The Markov-Chain Monte Carlo method is used to sample from the joint probability distribution given arrival data sets. The differential time component of Bayesloc includes scaling a stochastic estimate of differential time measurement precision based the waveform correlation coefficient for each datum. For a regional-distance synthetic data set with absolute and differential time measurement error of 0.25 seconds and 0.01 second, respectively, epicenter location accuracy is improved from and average of 1.05 km when solely absolute time data are used to 0.28 km when absolute and differential time data are used jointly (73% improvement). The improvement in absolute location accuracy is the result of conditionally limiting absolute location probability regions based on the precise relative position with respect to neighboring events. Bayesloc estimates of data precision are found to be accurate for the synthetic test, with absolute and differential time measurement

  11. Absolute Transition Probabilities of Lines in the Spectra of Astrophysical Atoms, Molecules, and Ions

    NASA Technical Reports Server (NTRS)

    Parkinson, W. H.; Smith, P. L.; Yoshino, K.

    1984-01-01

    Progress in the investigation of absolute transition probabilities (A-values or F values) for ultraviolet lines is reported. A radio frequency ion trap was used for measurement of transition probabilities for intersystem lines seen in astronomical spectra. The intersystem line at 2670 A in Al II, which is seen in pre-main sequence stars and symbiotic stars, was studied.

  12. Multi-modality imaging for the assessment of myocardial perfusion with emphasis on stress perfusion CT and MR imaging.

    PubMed

    Ko, Sung Min; Hwang, Hweung Kon; Kim, Sung Mok; Cho, Ihn Ho

    2015-06-01

    High-quality and non-invasive diagnostic tools for assessing myocardial ischemia are necessary for therapeutic decisions regarding coronary artery disease. Myocardial perfusion has been studied using myocardial contrast echo perfusion, single-photon emission computed tomography, positron emission tomography, cardiovascular magnetic resonance, and, more recently, computed tomography. The addition of coronary computed tomography angiography to myocardial perfusion imaging improves the specificity and overall diagnostic accuracy of detecting the hemodynamic significance of coronary artery stenosis. This study reviews the benefits, limitations, and imaging findings of various imaging modalities for assessing myocardial perfusion, with particular emphasis on stress perfusion computed tomography and cardiovascular magnetic resonance imaging. PMID:25809387

  13. Perfusion delay causes unintentional ischemic preconditioning in isolated heart preparation.

    PubMed

    Minhaz, U; Koide, S; Shohtsu, A; Fujishima, M; Nakazawa, H

    1995-01-01

    This study sought to show that unintentional preconditioning can be induced in the isolated perfused heart during the preparation procedure. The following four groups were compared: hearts were placed in ice cold saline and cooled for 15 s and then mounted to the Langendorff apparatus (n = 5; cool immediate group); hearts were cooled for 60 s and mounted (n = 5; cool delay group); hearts were mounted directly to the apparatus within 15 s after the isolation without cooling (n = 5; noncool immediate group); hearts were mounted without cooling, but the mounting was delayed for 60 s after the isolation (n = 5; noncool delay group). All hearts were paced at a fixed rate of 300 bpm, and an occlusion of left coronary (LCA) for 60 min was performed, which was followed by reperfusion for another 60 min. Coronary flow (CBF), left ventricular developed pressure (LVDP), and creatine phosphokinase (CPK) release did not change among the four groups during ischemia. At the end of reperfusion the LVDP values were 70 +/- 1%, 66 +/- 2%, 62 +/- 3%, and 73 +/- 2% of preischemic values in cool immediate, cool delay, noncool immediate, and noncool delay groups, respectively. CPK values were 116 +/- 4, 121 +/- 7, 138 +/- 6, and 29 +/- 1 x 10(3) U/g myocardium, and percentage necrosis/risk areas were 24 +/- 1.0%, 21 +/- 1.7%, 38 +/- 2.6%, and 13 +/- 0.5% in cool immediate, cool delay, noncool immediate, and noncool delay groups, respectively. The noncool delay group demonstrated high LVDP, least amount of CPK release, and smallest size of necrosis. These results indicate that an unintentional preconditioning effect can be induced when the cooling procedure is not applied and perfusion is delayed. PMID:8585864

  14. Luminal perfusion of isolated gastric glands.

    PubMed

    Waisbren, S J; Geibel, J; Boron, W F; Modlin, I M

    1994-04-01

    We have extended to rabbit gastric glands the technique for perfusing single isolated renal tubules. We isolated glands by hand dissection and used concentric glass pipettes to hold them and perfuse their lumina. Parietal cells (PCs), which tended to be located toward the gland opening, were identified by their pyramidal shape, large size, and autofluorescence. Chief cells (CCs) were identified by their round shape and smaller size. In some experiments, we perfused the lumen with hydroxypyrenetrisulfonate, a pH-sensitive fluorophore, at pH 7.4 and used digital image processing to monitor luminal pH (pH1). Solutions were buffered with N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid to pH 7.4 at 37 degrees C. With fast perfusion, we found no evidence of decreased pH1, even with stimulation by 10 microM carbachol. With slow perfusion, pH1 often fell below the dye's sensitive range (pH < 5), especially at low perfusate buffering power. In other experiments, we loaded cells with the pH-sensitive dye 2',7'-bis(2-carboxyethyl)-5(6)-carboxyfluorescein and monitored intracellular pH (pHi) in multiple individual PCs and CCs in a single gland. Mean pHi was 7.21 +/- 0.02 (n = 136 cells) for PCs and 7.27 +/- 0.03 (n = 103) for CCs. To examine the response to decreased pH1 and basolateral pH (pHb), we lowered pHb to 6.4 or lowered pH1 to 3.4 or 1.4. Lowering pHb to 6.4 for approximately 1 min caused pHi to fall reversibly by 0.39 +/- 0.05 (n = 53) in PCs and 0.58 +/- 0.03 (n = 50) in CCs. Lowering pH1 to 3.4 or 1.4 caused no significant pHi changes in PCs (n = 38 and 82) or in CCs (n = 44 and 77). Carbachol did not affect the response to changes in pH1 or pHb. We conclude that the apical surfaces of PCs and CCs are unusually resistant to extreme pH gradients. PMID:8178950

  15. Development and validation of a segmentation-free polyenergetic algorithm for dynamic perfusion computed tomography.

    PubMed

    Lin, Yuan; Samei, Ehsan

    2016-07-01

    Dynamic perfusion imaging can provide the morphologic details of the scanned organs as well as the dynamic information of blood perfusion. However, due to the polyenergetic property of the x-ray spectra, beam hardening effect results in undesirable artifacts and inaccurate CT values. To address this problem, this study proposes a segmentation-free polyenergetic dynamic perfusion imaging algorithm (pDP) to provide superior perfusion imaging. Dynamic perfusion usually is composed of two phases, i.e., a precontrast phase and a postcontrast phase. In the precontrast phase, the attenuation properties of diverse base materials (e.g., in a thorax perfusion exam, base materials can include lung, fat, breast, soft tissue, bone, and metal implants) can be incorporated to reconstruct artifact-free precontrast images. If patient motions are negligible or can be corrected by registration, the precontrast images can then be employed as a priori information to derive linearized iodine projections from the postcontrast images. With the linearized iodine projections, iodine perfusion maps can be reconstructed directly without the influence of various influential factors, such as iodine location, patient size, x-ray spectrum, and background tissue type. A series of simulations were conducted on a dynamic iodine calibration phantom and a dynamic anthropomorphic thorax phantom to validate the proposed algorithm. The simulations with the dynamic iodine calibration phantom showed that the proposed algorithm could effectively eliminate the beam hardening effect and enable quantitative iodine map reconstruction across various influential factors. The error range of the iodine concentration factors ([Formula: see text]) was reduced from [Formula: see text] for filtered back-projection (FBP) to [Formula: see text] for pDP. The quantitative results of the simulations with the dynamic anthropomorphic thorax phantom indicated that the maximum error of iodine concentrations can be reduced from

  16. Use of intensity quotients and differences in absolute structure refinement

    PubMed Central

    Parsons, Simon; Flack, Howard D.; Wagner, Trixie

    2013-01-01

    Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement. PMID:23719469

  17. Use of intensity quotients and differences in absolute structure refinement.

    PubMed

    Parsons, Simon; Flack, Howard D; Wagner, Trixie

    2013-06-01

    Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement. PMID:23719469

  18. Absolute and relative dosimetry for ELIMED

    SciTech Connect

    Cirrone, G. A. P.; Schillaci, F.; Scuderi, V.; Cuttone, G.; Candiano, G.; Musumarra, A.; Pisciotta, P.; Romano, F.; Carpinelli, M.; Presti, D. Lo; Raffaele, L.; Tramontana, A.; Cirio, R.; Sacchi, R.; Monaco, V.; Marchetto, F.; Giordanengo, S.

    2013-07-26

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  19. Absolute-magnitude distributions of supernovae

    SciTech Connect

    Richardson, Dean; Wright, John; Jenkins III, Robert L.; Maddox, Larry

    2014-05-01

    The absolute-magnitude distributions of seven supernova (SN) types are presented. The data used here were primarily taken from the Asiago Supernova Catalogue, but were supplemented with additional data. We accounted for both foreground and host-galaxy extinction. A bootstrap method is used to correct the samples for Malmquist bias. Separately, we generate volume-limited samples, restricted to events within 100 Mpc. We find that the superluminous events (M{sub B} < –21) make up only about 0.1% of all SNe in the bias-corrected sample. The subluminous events (M{sub B} > –15) make up about 3%. The normal Ia distribution was the brightest with a mean absolute blue magnitude of –19.25. The IIP distribution was the dimmest at –16.75.

  20. Absolute calibration of TFTR helium proportional counters

    SciTech Connect

    Strachan, J.D.; Diesso, M.; Jassby, D.; Johnson, L.; McCauley, S.; Munsat, T.; Roquemore, A.L.; Barnes, C.W. |; Loughlin, M. |

    1995-06-01

    The TFTR helium proportional counters are located in the central five (5) channels of the TFTR multichannel neutron collimator. These detectors were absolutely calibrated using a 14 MeV neutron generator positioned at the horizontal midplane of the TFTR vacuum vessel. The neutron generator position was scanned in centimeter steps to determine the collimator aperture width to 14 MeV neutrons and the absolute sensitivity of each channel. Neutron profiles were measured for TFTR plasmas with time resolution between 5 msec and 50 msec depending upon count rates. The He detectors were used to measure the burnup of 1 MeV tritons in deuterium plasmas, the transport of tritium in trace tritium experiments, and the residual tritium levels in plasmas following 50:50 DT experiments.

  1. Absolute enantioselective separation: optical activity ex machina.

    PubMed

    Bielski, Roman; Tencer, Michal

    2005-11-01

    The paper describes methodology of using three independent macroscopic factors affecting molecular orientation to accomplish separation of a racemic mixture without the presence of any other chiral compounds, i. e., absolute enantioselective separation (AES) which is an extension of a concept of applying these factors to absolute asymmetric synthesis. The three factors may be applied simultaneously or, if their effects can be retained, consecutively. The resulting three mutually orthogonal or near orthogonal directors constitute a true chiral influence and their scalar triple product is the measure of the chirality of the system. AES can be executed in a chromatography-like microfluidic process in the presence of an electric field. It may be carried out on a chemically modified flat surface, a monolithic polymer column made of a mesoporous material, each having imparted directional properties. Separation parameters were estimated for these media and possible implications for the natural homochirality are discussed. PMID:16342798

  2. An absolute measure for a key currency

    NASA Astrophysics Data System (ADS)

    Oya, Shunsuke; Aihara, Kazuyuki; Hirata, Yoshito

    It is generally considered that the US dollar and the euro are the key currencies in the world and in Europe, respectively. However, there is no absolute general measure for a key currency. Here, we investigate the 24-hour periodicity of foreign exchange markets using a recurrence plot, and define an absolute measure for a key currency based on the strength of the periodicity. Moreover, we analyze the time evolution of this measure. The results show that the credibility of the US dollar has not decreased significantly since the Lehman shock, when the Lehman Brothers bankrupted and influenced the economic markets, and has increased even relatively better than that of the euro and that of the Japanese yen.

  3. From Hubble's NGSL to Absolute Fluxes

    NASA Technical Reports Server (NTRS)

    Heap, Sara R.; Lindler, Don

    2012-01-01

    Hubble's Next Generation Spectral Library (NGSL) consists of R-l000 spectra of 374 stars of assorted temperature, gravity, and metallicity. Each spectrum covers the wavelength range, 0.18-1.00 microns. The library can be viewed and/or downloaded from the website, http://archive.stsci.edu/prepds/stisngsll. Stars in the NGSL are now being used as absolute flux standards at ground-based observatories. However, the uncertainty in the absolute flux is about 2%, which does not meet the requirements of dark-energy surveys. We are therefore developing an observing procedure that should yield fluxes with uncertainties less than 1 % and will take part in an HST proposal to observe up to 15 stars using this new procedure.

  4. On determining absolute entropy without quantum theory or the third law of thermodynamics

    NASA Astrophysics Data System (ADS)

    Steane, Andrew M.

    2016-04-01

    We employ classical thermodynamics to gain information about absolute entropy, without recourse to statistical methods, quantum mechanics or the third law of thermodynamics. The Gibbs–Duhem equation yields various simple methods to determine the absolute entropy of a fluid. We also study the entropy of an ideal gas and the ionization of a plasma in thermal equilibrium. A single measurement of the degree of ionization can be used to determine an unknown constant in the entropy equation, and thus determine the absolute entropy of a gas. It follows from all these examples that the value of entropy at absolute zero temperature does not need to be assigned by postulate, but can be deduced empirically.

  5. Metallic Magnetic Calorimeters for Absolute Activity Measurement

    NASA Astrophysics Data System (ADS)

    Loidl, M.; Leblanc, E.; Rodrigues, M.; Bouchard, J.; Censier, B.; Branger, T.; Lacour, D.

    2008-05-01

    We present a prototype of metallic magnetic calorimeters that we are developing for absolute activity measurements of low energy emitting radionuclides. We give a detailed description of the realization of the prototype, containing an 55Fe source inside the detector absorber. We present the analysis of first data taken with this detector and compare the result of activity measurement with liquid scintillation counting. We also propose some ways for reducing the uncertainty on the activity determination with this new technique.

  6. Silicon Absolute X-Ray Detectors

    SciTech Connect

    Seely, John F.; Korde, Raj; Sprunck, Jacob; Medjoubi, Kadda; Hustache, Stephanie

    2010-06-23

    The responsivity of silicon photodiodes having no loss in the entrance window, measured using synchrotron radiation in the 1.75 to 60 keV range, was compared to the responsivity calculated using the silicon thickness measured using near-infrared light. The measured and calculated responsivities agree with an average difference of 1.3%. This enables their use as absolute x-ray detectors.

  7. Blood pressure targets and absolute cardiovascular risk.

    PubMed

    Odutayo, Ayodele; Rahimi, Kazem; Hsiao, Allan J; Emdin, Connor A

    2015-08-01

    In the Eighth Joint National Committee guideline on hypertension, the threshold for the initiation of blood pressure-lowering treatment for elderly adults (≥60 years) without chronic kidney disease or diabetes mellitus was raised from 140/90 mm Hg to 150/90 mm Hg. However, the committee was not unanimous in this decision, particularly because a large proportion of adults ≥60 years may be at high cardiovascular risk. On the basis of Eighth Joint National Committee guideline, we sought to determine the absolute 10-year risk of cardiovascular disease among these adults through analyzing the National Health and Nutrition Examination Survey (2005-2012). The primary outcome measure was the proportion of adults who were at ≥20% predicted absolute cardiovascular risk and above goals for the Seventh Joint National Committee guideline but reclassified as at target under the Eighth Joint National Committee guideline (reclassified). The Framingham General Cardiovascular Disease Risk Score was used. From 2005 to 2012, the surveys included 12 963 adults aged 30 to 74 years with blood pressure measurements, of which 914 were reclassified based on the guideline. Among individuals reclassified as not in need of additional treatment, the proportion of adults 60 to 74 years without chronic kidney disease or diabetes mellitus at ≥20% absolute risk was 44.8%. This corresponds to 0.8 million adults. The proportion at high cardiovascular risk remained sizable among adults who were not receiving blood pressure-lowering treatment. Taken together, a sizable proportion of reclassified adults 60 to 74 years without chronic kidney disease or diabetes mellitus was at ≥20% absolute cardiovascular risk. PMID:26056340

  8. Relative errors can cue absolute visuomotor mappings.

    PubMed

    van Dam, Loes C J; Ernst, Marc O

    2015-12-01

    When repeatedly switching between two visuomotor mappings, e.g. in a reaching or pointing task, adaptation tends to speed up over time. That is, when the error in the feedback corresponds to a mapping switch, fast adaptation occurs. Yet, what is learned, the relative error or the absolute mappings? When switching between mappings, errors with a size corresponding to the relative difference between the mappings will occur more often than other large errors. Thus, we could learn to correct more for errors with this familiar size (Error Learning). On the other hand, it has been shown that the human visuomotor system can store several absolute visuomotor mappings (Mapping Learning) and can use associated contextual cues to retrieve them. Thus, when contextual information is present, no error feedback is needed to switch between mappings. Using a rapid pointing task, we investigated how these two types of learning may each contribute when repeatedly switching between mappings in the absence of task-irrelevant contextual cues. After training, we examined how participants changed their behaviour when a single error probe indicated either the often-experienced error (Error Learning) or one of the previously experienced absolute mappings (Mapping Learning). Results were consistent with Mapping Learning despite the relative nature of the error information in the feedback. This shows that errors in the feedback can have a double role in visuomotor behaviour: they drive the general adaptation process by making corrections possible on subsequent movements, as well as serve as contextual cues that can signal a learned absolute mapping. PMID:26280315

  9. Absolute distance measurements by variable wavelength interferometry

    NASA Astrophysics Data System (ADS)

    Bien, F.; Camac, M.; Caulfield, H. J.; Ezekiel, S.

    1981-02-01

    This paper describes a laser interferometer which provides absolute distance measurements using tunable lasers. An active feedback loop system, in which the laser frequency is locked to the optical path length difference of the interferometer, is used to tune the laser wavelengths. If the two wavelengths are very close, electronic frequency counters can be used to measure the beat frequency between the two laser frequencies and thus to determine the optical path difference between the two legs of the interferometer.

  10. Perfusion techniques for minimally invasive valve procedures.

    PubMed

    de Jong, A; Popa, B A; Stelian, E; Karazanishvili, L; Lanzillo, G; Simonini, S; Renzi, L; Diena, M; Tesler, U F

    2015-05-01

    In this paper, we present, in detail, the simplified perfusion technique that we have adopted since January 2009 and that we have utilized in 200 cases for cardiac minimally invasive valvular procedures that were performed through a right lateral mini-thoracotomy in the 3(rd)-4(th) intercostal space. Cardiopulmonary bypass was achieved by means of the direct cannulation of the ascending aorta and the insertion of a percutaneous venous cannula in the femoral vein. A flexible aortic cross-clamp was applied through the skin incision and cardioplegic arrest was obtained with the antegrade delivery of a crystalloid solution. Gravity drainage was enhanced by vacuum-assisted aspiration. There were no technical complications related to this perfusion technique that we have adopted in minimally invasive surgical procedures. PMID:25280878

  11. Assessment of cerebral perfusion in childhood strokes

    SciTech Connect

    Gates, G.F.; Fishman, L.S.; Segall, H.D.

    1982-11-01

    Thirty-three children who had strokes were studied by dynamic and static scintigraphy, 29 by CT scanning, and 10 by cerebral angiography. The accuracy of dynamic scintigraphy in stroke detection during the first week of clinical symptoms was 94% while CT scanning was 60% accurate and static scintigraphy 11% accurate. During the second week the accuracy of CT scanning increased to 100%, but static scintigraphy improved to only 50%. Fifty percent of scintiangiograms performed during the first week showed either luxuriant perfusion or flip-flop patterns. In some patients these two flow patterns changed to that of cerebral hemispheric ischemia after going through a phase during which perfusion appeared to be equal in the two hemispheres. Dynamic scintigraphy is believed to be the test of choice for stroke detection in children during the first week.

  12. Visual analysis of longitudinal brain tumor perfusion

    NASA Astrophysics Data System (ADS)

    Glaßer, Sylvia; Oeltze, Steffen; Preim, Uta; Bjørnerud, Atle; Hauser, Helwig; Preim, Bernhard

    2013-02-01

    In clinical research on diagnosis and evaluation of brain tumors, longitudinal perfusion MRI studies are acquired for tumor grading as well as to monitor and assess treatment response and patient prognosis. Within this work, we demonstrate how visual analysis techniques can be adapted to multidimensional datasets from such studies within a framework to support the computer-aided diagnosis of brain tumors. Our solution builds on two innovations: First, we introduce a pipeline yielding comparative, co-registered quantitative perfusion parameter maps over all time steps of the longitudinal study. Second, based on these time-dependent parameter maps, visual analysis methods were developed and adapted to reveal valuable insight into tumor progression, especially regarding the clinical research area of low grade glioma transformation into high grade gliomas. Our examination of four longitudinal brain studies demonstrates the suitability of the presented visual analysis methods and comprises new possibilities for the clinical researcher to characterize the development of low grade gliomas.

  13. Absolute dosimetry for extreme-ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Berger, Kurt W.; Campiotti, Richard H.

    2000-06-01

    The accurate measurement of an exposure dose reaching the wafer on an extreme ultraviolet (EUV) lithographic system has been a technical challenge directly applicable to the evaluation of candidate EUV resist materials and calculating lithography system throughputs. We have developed a dose monitoring sensor system that can directly measure EUV intensities at the wafer plane of a prototype EUV lithographic system. This sensor system, located on the wafer stage adjacent to the electrostatic chuck used to grip wafers, operates by translating the sensor into the aerial image, typically illuminating an 'open' (unpatterned) area on the reticle. The absolute signal strength can be related to energy density at the wafer, and thus used to determine resist sensitivity, and the signal as a function of position can be used to determine illumination uniformity at the wafer plane. Spectral filtering to enhance the detection of 13.4 nm radiation was incorporated into the sensor. Other critical design parameters include the packaging and amplification technologies required to place this device into the space and vacuum constraints of a EUV lithography environment. We describe two approaches used to determine the absolute calibration of this sensor. The first conventional approach requires separate characterization of each element of the sensor. A second novel approach uses x-ray emission from a mildly radioactive iron source to calibrate the absolute response of the entire sensor system (detector and electronics) in a single measurement.

  14. Gluconeogenesis in the perfused rat liver.

    PubMed

    Hems, R; Ross, B D; Berry, M N; Krebs, H A

    1966-11-01

    1. A modification of the methods of Miller and of Schimassek for the perfusion of the isolated rat liver, suitable for the study of gluconeogenesis, is described. 2. The main modifications concern the operative technique (reducing the period of anoxia during the operation to 3min.) and the use of aged (non-glycolysing) red cells in the semi-synthetic perfusion medium. 3. The performance of the perfused liver was tested by measuring the rate of gluconeogenesis, of urea synthesis and the stability of adenine nucleotides. Higher rates of gluconeogenesis (1mumole/min./g.) from excess of lactate and of urea synthesis from excess of ammonia (4mumoles/min./g. in the presence of ornithine) were observed than are likely to occur in vivo where rates are limited by the rate of supply of precursor. The concentrations of the three adenine nucleotides in the liver tissue were maintained within 15% over a perfusion period of 135min. 4. Ca(2+), Na(+), K(+), Mg(2+) and phosphate were found to be required at physiological concentrations for optimum gluconeogenesis but bicarbonate and carbon dioxide could be largely replaced by phosphate buffer without affecting the rate of gluconeogenesis. 5. Maximal gluconeogenesis did not decrease maximal urea synthesis in the presence of ornithine and ammonia and vice versa. This indicates that the energy requirements were not limiting the rates of gluconeogenesis or of urea synthesis. 6. Addition of lactate, and especially ammonium salts, increased the uptake of oxygen more than expected on the basis of the ATP requirements of the gluconeogenesis and urea synthesis. PMID:5966267

  15. Dynamic CT perfusion measurement in a cardiac phantom.

    PubMed

    Ziemer, Benjamin P; Hubbard, Logan; Lipinski, Jerry; Molloi, Sabee

    2015-10-01

    Widespread clinical implementation of dynamic CT myocardial perfusion has been hampered by its limited accuracy and high radiation dose. The purpose of this study was to evaluate the accuracy and radiation dose reduction of a dynamic CT myocardial perfusion technique based on first pass analysis (FPA). To test the FPA technique, a pulsatile pump was used to generate known perfusion rates in a range of 0.96-2.49 mL/min/g. All the known perfusion rates were determined using an ultrasonic flow probe and the known mass of the perfusion volume. FPA and maximum slope model (MSM) perfusion rates were measured using volume scans acquired from a 320-slice CT scanner, and then compared to the known perfusion rates. The measured perfusion using FPA (P(FPA)), with two volume scans, and the maximum slope model (P(MSM)) were related to known perfusion (P(K)) by P(FPA) = 0.91P(K) + 0.06 (r = 0.98) and P(MSM) = 0.25P(K) - 0.02 (r = 0.96), respectively. The standard error of estimate for the FPA technique, using two volume scans, and the MSM was 0.14 and 0.30 mL/min/g, respectively. The estimated radiation dose required for the FPA technique with two volume scans and the MSM was 2.6 and 11.7-17.5 mSv, respectively. Therefore, the FPA technique can yield accurate perfusion measurements using as few as two volume scans, corresponding to approximately a factor of four reductions in radiation dose as compared with the currently available MSM. In conclusion, the results of the study indicate that the FPA technique can make accurate dynamic CT perfusion measurements over a range of clinically relevant perfusion rates, while substantially reducing radiation dose, as compared to currently available dynamic CT perfusion techniques. PMID:26156231

  16. Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure

    PubMed Central

    Shojaeifard, Maryam; Ghaedian, Tahereh; Yaghoobi, Nahid; Malek, Hadi; Firoozabadi, Hasan; Bitarafan-Rajabi, Ahmad; Haghjoo, Majid; Amin, Ahmad; Azizian, Nasrin; Rastgou, Feridoon

    2015-01-01

    Background: Gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is known as a feasible tool for the measurement of left ventricular ejection fraction (EF) and volumes, which are of great importance in the management and follow-up of patients with coronary artery diseases. However, considering the technical shortcomings of SPECT in the presence of perfusion defect, the accuracy of this method in heart failure patients is still controversial. Objectives: The aim of the present study was to compare the results from gated SPECT MPI with those from echocardiography in heart failure patients to compare echocardiographically-derived left ventricular dimension and function data to those from gated SPECT MPI in heart failure patients. Patients and Methods: Forty-one patients with severely reduced left ventricular systolic function (EF ≤ 35%) who were referred for gated SPECT MPI were prospectively enrolled. Quantification of EF, end-diastolic volume (EDV), and end-systolic volume (ESV) was performed by using quantitative gated spect (QGS) (QGS, version 0.4, May 2009) and emory cardiac toolbox (ECTb) (ECTb, revision 1.0, copyright 2007) software packages. EF, EDV, and ESV were also measured with two-dimensional echocardiography within 3 days after MPI. Results: A good correlation was found between echocardiographically-derived EF, EDV, and ESV and the values derived using QGS (r = 0.67, r = 0.78, and r = 0.80 for EF, EDV, and ESV, respectively; P < 0.001) and ECTb (r = 0.68, 0.79, and r = 0.80 for EF, EDV, and ESV, respectively; P < 0.001). However, Bland-Altman plots indicated significantly different mean values for EF, 11.4 and 20.9 using QGS and ECTb, respectively, as compared with echocardiography. ECTb-derived EDV was also significantly higher than the EDV measured with echocardiography and QGS. The highest correlation between echocardiography and gated SPECT MPI was found for mean values of ESV different. Conclusions: Gated

  17. A method of determining electrical potential gradient across mitochondrial membrane in perfused rat hearts.

    PubMed

    Wan, B; Doumen, C; Duszynski, J; Salama, G; LaNoue, K F

    1993-08-01

    The electrical potential gradient across the mitochondrial membrane (delta psi m) in perfused rat hearts was estimated by calculating the equilibrium distribution of the lipophilic cation tetraphenylphosphonium (TPP+), using measured kinetic constants of uptake and release of TPP+. First-order rate constants of TPP+ uptake were measured during 30-min perfusions of intact rat hearts with tracer amounts (5.0 nM) of tritium-labeled TPP+ ([3H]TPP+) in the perfusate. This was followed by a 30-min washout, during which the first-order rate constant of efflux was estimated. Values of [3H]TPP+ outside the heart and total [3H]TPP+ inside the heart at equilibrium were calculated. From this information and separately estimated time-averaged plasma membrane potentials (delta psi c) it was possible to calculate free cytosolic [3H]TPP+ at equilibrium. It was also possible to calculate free intramitochondrial [3H]TPP+ at equilibrium as the difference between total tissue [3H]TPP+ minus free cytosolic TPP+ and the sum of all the bound [3H]TPP+. Bound [3H]TPP+ was determined from [3H]TPP+ binding constants measured in separate experiments, using both isolated mitochondria and isolated cardiac myocytes under conditions where both delta psi m and delta psi c were zero. Delta psi m was calculated from the intramitochondrial and cytosolic free TPP+ concentrations using the Nernst equation. Values of delta psi m were 144.9 +/- 2.0 mV in hearts perfused with 5 mM pyruvate and 118.2 +/- 1.4 mV in hearts perfused with 11 mM glucose, in good agreement with delta psi m obtained from isolated rat heart mitochondria.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8368347

  18. Clinical decision making with myocardial perfusion imaging in patients with known or suspected coronary artery disease.

    PubMed

    Cremer, Paul; Hachamovitch, Rory; Tamarappoo, Balaji

    2014-07-01

    Myocardial perfusion imaging (MPI) to diagnose coronary artery disease (CAD) is best performed in patients with intermediate pretest likelihood of disease; unfortunately, pretest likelihood is often overestimated, resulting in the inappropriate use of perfusion imaging. A good functional capacity often predicts low risk, and MPI for diagnosing CAD should be reserved for individuals with poor exercise capacity, abnormal resting electrocardiography, or an intermediate or high probability of CAD. With respect to anatomy-based testing, coronary CT angiography has a good negative predictive value, but stenosis severity correlates poorly with ischemia. Therefore decision making with respect to revascularization may be limited when a purely noninvasive anatomical test is used. Regarding perfusion imaging, the diagnostic accuracies of SPECT, PET, and cardiac magnetic resonance are similar, though fewer studies are available with cardiac magnetic resonance. PET coronary flow reserve may offer a negative predictive value sufficiently high to exclude severe CAD such that patients with mild to moderate reversible perfusion defects can forego invasive angiography. In addition, combined anatomical and perfusion-based imaging may eventually offer a definitive evaluation for diagnosing CAD, even in higher risk patients. Any remarkable findings on single-photon emission computed tomography and PET MPI studies are valuable for prognostication. Furthermore, assessment of myocardial blood flow with PET is particularly powerful for prognostication as it reflects the end result of many processes that lead to atherosclerosis. Decision making with respect to revascularization is limited for cardiac MRI and PET MPI. In contrast, retrospective radionuclide studies have identified an ischemic threshold, but randomized trials are needed. In patients with at least moderately reduced left ventricular systolic function, viable myocardium as assessed by PET or MRI, appears to identify patients

  19. Estimation of intra-operator variability in perfusion parameter measurements using DCE-US

    PubMed Central

    Gauthier, Marianne; Leguerney, Ingrid; Thalmensi, Jessie; Chebil, Mohamed; Parisot, Sarah; Peronneau, Pierre; Roche, Alain; Lassau, Nathalie

    2011-01-01

    AIM: To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue®. METHODS: The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue® (Bracco, Milan, Italy) and using a Toshiba Aplio® ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging (“Vascular Recognition Imaging”) involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV). RESULTS: In vitro, different volumes of SonoVue® were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%. CONCLUSION: AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values. PMID:21512654

  20. Inhomogeneity of pulmonary perfusion during sustained microgravity

    NASA Technical Reports Server (NTRS)

    Prisk, G. Kim; Guy, Harold J. B.; Elliott, Ann R.; West, John B.

    1994-01-01

    The effects of gravity on the inhomogeneity of pulmonary perfusion in man were studied by performing hyperventilation-breathhold single-breath measurements before, during and after 9 days of continuous exposure to microgravity. In microgravity the indicators of inhomogeneity of perfusion, especially the size of cardiogenic oscillations in expired CO2 and the height of phase 4, were both markedly reduced. Cardiogenic oscillations were reduced to approximately 60 of their preflight standing size, while the height of phase 4 was between 0 and -8% (a terminal fall became a small terminal rise) of preflights standing. The terminal change in CO2 was nearly abolished in microgravity indicating more uniformity of blood flow between lung units that close at the end of expiration and units that remain open. This may result from the disappearance of gravity-dependent topographical inequality of blood flow. The residual cardiographic oscillations in expired CO2 imply a persisting inhomogeneity of perfusion in the absence of gravity at a level larger than acinar.

  1. Regulation of skeletal muscle perfusion during exercise

    NASA Technical Reports Server (NTRS)

    Delp, M. D.; Laughlin, M. H.

    1998-01-01

    For exercise to be sustained, it is essential that adequate blood flow be provided to skeletal muscle. The local vascular control mechanisms involved in regulating muscle perfusion during exercise include metabolic control, endothelium-mediated control, propagated responses, myogenic control, and the muscle pump. The primary determinant of muscle perfusion during sustained exercise is the metabolic rate of the muscle. Metabolites from contracting muscle diffuse to resistance arterioles and act directly to induce vasodilation, or indirectly to inhibit noradrenaline release from sympathetic nerve endings and oppose alpha-adrenoreceptor-mediated vasoconstriction. The vascular endothelium also releases vasodilator substances (e.g., prostacyclin and nitric oxide) that are prominent in establishing basal vascular tone, but these substances do not appear to contribute to the exercise hyperemia in muscle. Endothelial and smooth muscle cells may also be involved in propagating vasodilator signals along arterioles to parent and daughter vessels. Myogenic autoregulation does not appear to be involved in the exercise hyperemia in muscle, but the rhythmic propulsion of blood from skeletal muscle veins facilitates venous return to the heart and muscle perfusion. It appears that the primary determinants of sustained exercise hyperemia in skeletal muscle are metabolic vasodilation and increased vascular conductance via the muscle pump. Additionally, sympathetic neural control is important in regulating muscle blood flow during exercise.

  2. Perfusion computed tomography in renal cell carcinoma.

    PubMed

    Das, Chandan J; Thingujam, Usha; Panda, Ananya; Sharma, Sanjay; Gupta, Arun Kumar

    2015-07-28

    Various imaging modalities are available for the diagnosis, staging and response evaluation of patients with renal cell carcinoma (RCC). While contrast enhanced computed tomography (CT) is used as the standard of imaging for size, morphological evaluation and response assessment in RCC, a new functional imaging technique like perfusion CT (pCT), goes down to the molecular level and provides new perspectives in imaging of RCC. pCT depicts regional tumor perfusion and vascular permeability which are indirect parameters of tumor angiogenesis and thereby provides vital information regarding tumor microenvironment. Also response evaluation using pCT may predate the size criteria used in Response Evaluation Criteria in Solid Tumors, as changes in the perfusion occurs earlier following tissue kinase inhibitors before any actual change in size. This may potentially help in predicting prognosis, better selection of therapy and more accurate and better response evaluation in patients with RCC. This article describes the techniques and role of pCT in staging and response assessment in patients with RCCs. PMID:26217456

  3. Noncontact blood perfusion mapping in clinical applications

    NASA Astrophysics Data System (ADS)

    Iakovlev, Dmitry; Dwyer, Vincent; Hu, Sijung; Silberschmidt, Vadim

    2016-04-01

    Non-contact imaging photoplethysmography (iPPG) to detect pulsatile blood microcirculation in tissue has been selected as a successor to low spatial resolution and slow scanning blood perfusion techniques currently employed by clinicians. The proposed iPPG system employs a novel illumination source constructed of multiple high power LEDs with narrow spectral emission, which are temporally modulated and synchronised with a high performance sCMOS sensor. To ensure spectrum stability and prevent thermal wavelength drift due to junction temperature variations, each LED features a custom-designed thermal management system to effectively dissipate generated heat and auto-adjust current flow. The use of a multi-wavelength approach has resulted in simultaneous microvascular perfusion monitoring at various tissue depths, which is an added benefit for specific clinical applications. A synchronous detection algorithm to extract weak photoplethysmographic pulse-waveforms demonstrated robustness and high efficiency when applied to even small regions of 5 mm2. The experimental results showed evidences that the proposed system could achieve noticeable accuracy in blood perfusion monitoring by creating complex amplitude and phase maps for the tissue under examination.

  4. Parallel perfusion imaging processing using GPGPU

    PubMed Central

    Zhu, Fan; Gonzalez, David Rodriguez; Carpenter, Trevor; Atkinson, Malcolm; Wardlaw, Joanna

    2012-01-01

    Background and purpose The objective of brain perfusion quantification is to generate parametric maps of relevant hemodynamic quantities such as cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) that can be used in diagnosis of acute stroke. These calculations involve deconvolution operations that can be very computationally expensive when using local Arterial Input Functions (AIF). As time is vitally important in the case of acute stroke, reducing the analysis time will reduce the number of brain cells damaged and increase the potential for recovery. Methods GPUs originated as graphics generation dedicated co-processors, but modern GPUs have evolved to become a more general processor capable of executing scientific computations. It provides a highly parallel computing environment due to its large number of computing cores and constitutes an affordable high performance computing method. In this paper, we will present the implementation of a deconvolution algorithm for brain perfusion quantification on GPGPU (General Purpose Graphics Processor Units) using the CUDA programming model. We present the serial and parallel implementations of such algorithms and the evaluation of the performance gains using GPUs. Results Our method has gained a 5.56 and 3.75 speedup for CT and MR images respectively. Conclusions It seems that using GPGPU is a desirable approach in perfusion imaging analysis, which does not harm the quality of cerebral hemodynamic maps but delivers results faster than the traditional computation. PMID:22824549

  5. Whole Animal Perfusion Fixation for Rodents

    PubMed Central

    Gage, Gregory J.; Kipke, Daryl R.; Shain, William

    2012-01-01

    The goal of fixation is to rapidly and uniformly preserve tissue in a life-like state. While placing tissue directly in fixative works well for small pieces of tissue, larger specimens like the intact brain pose a problem for immersion fixation because the fixative does not reach all regions of the tissue at the same rate 5,7. Often, changes in response to hypoxia begin before the tissue can be preserved 12. The advantage of directly perfusing fixative through the circulatory system is that the chemical can quickly reach every corner of the organism using the natural vascular network. In order to utilize the circulatory system most effectively, care must be taken to match physiological pressures 3. It is important to note that physiological pressures are dependent on the species used. Techniques for perfusion fixation vary depending on the tissue to be fixed and how the tissue will be processed following fixation. In this video, we describe a low-cost, rapid, controlled and uniform fixation procedure using 4% paraformaldehyde perfused via the vascular system: through the heart of the rat to obtain the best possible preservation of the brain for immunohistochemistry. The main advantage of this technique (vs. gravity-fed systems) is that the circulatory system is utilized most effectively. PMID:22871843

  6. Automatic detection of CT perfusion datasets unsuitable for analysis due to head movement of acute ischemic stroke patients.

    PubMed

    Fahmi, Fahmi; Marquering, Henk A; Streekstra, Geert J; Beenen, Ludo F M; Janssen, Natasja N Y; Majoie, Charles B L; van Bavel, Ed

    2014-01-01

    Head movement during brain Computed Tomography Perfusion (CTP) can deteriorate perfusion analysis quality in acute ischemic stroke patients. We developed a method for automatic detection of CTP datasets with excessive head movement, based on 3D image-registration of CTP, with non-contrast CT providing transformation parameters. For parameter values exceeding predefined thresholds, the dataset was classified as 'severely moved'. Threshold values were determined by digital CTP phantom experiments. The automated selection was compared to manual screening by 2 experienced radiologists for 114 brain CTP datasets. Based on receiver operator characteristics, optimal thresholds were found of respectively 1.0°, 2.8° and 6.9° for pitch, roll and yaw, and 2.8 mm for z-axis translation. The proposed method had a sensitivity of 91.4% and a specificity of 82.3%. This method allows accurate automated detection of brain CTP datasets that are unsuitable for perfusion analysis. PMID:24691387

  7. The "kidney-liver" multiorgan ex vivo perfused model improves the circuit's biochemical milieu during perfusion compared to the "liver-kidney" counterpart.

    PubMed

    Chung, Wen Yuan; Gravante, Gianpiero; Eltweri, Amar; Sorge, Roberto; Ong, Seok Ling; Pollard, Cristina; Metcalfe, Mathew; Dennison, Ashley

    2015-06-01

    The multiorgan ex vivo perfused liver-kidney model allows studying the hepatic pathophysiology and purifying waste products. We tested if the addition of the kidney first followed by the liver (KL circuit) produces better results compared to the classic liver-first approach (LK). Intact livers and kidneys were obtained post mortem from ten female domestic white pigs, five experiments were conducted with the KL circuit and five with the LK. Bile, urine production, arterial blood gases, glucose, renal and liver tests were collected hourly during the perfusions. The KL circuit had values more close to physiological ranges, more stable over time and showed less variability compared to the LK circuit for urine production, glucose, PH, anion gap, lactate, urea, sodium, potassium and Alanine Transaminase (ANOVA test for repeated measures p < 0.05). The KL circuit produced a more physiological and reliable biochemical milieu. PMID:25557139

  8. Changes of perfusion of microvascular free flaps in the head and neck: a prospective clinical study.

    PubMed

    Mücke, Thomas; Rau, Andrea; Merezas, Andreas; Kanatas, Anastasios; Mitchell, David A; Wagenpfeil, Stefan; Wolff, Klaus-Dietrich; Steiner, Timm

    2014-11-01

    Reconstruction with a free flap is routine in head and neck surgery. However, reliable assessment of perfusion can be difficult, so we prospectively evaluated it in 4 types of microvascular free flaps in the oral cavity (n=196) and assessed differences in blood flow by non-invasive monitoring with a laser Doppler flowmetry unit. We measured oxygen saturation, haemoglobin concentration, and velocity on the surface of the flap preoperatively at the donor site, and on the flap on the first, second, and seventh postoperative days, and after 4 weeks in 186/196 patients, mean (SD) age of 60 (13) years. We studied the radial forearm (n=76, 41%), fibular (n=45, 24%), anterolateral thigh (n=53, 28%), and soleus perforator (n=12, 7%) flaps. The values for the radial forearm flap differed significantly from the others. There were significant differences in haemoglobin concentrations between the fibular and soleus perforator flaps, and between the anterolateral thigh and soleus perforator flaps (p=0.002 each). Free flaps are unique in the way that perfusion develops after microvascular anastomoses. Knowledge of how each flap is perfused may indicate different patterns of healing that could potentially influence long term rehabilitation and detection of future deficits in perfusion. PMID:25149324

  9. Effect of methotrexate on perfusion and nitrogen-13 glutamate uptake in the Walker-256 carcinosarcoma

    SciTech Connect

    Knapp, W.H.; Panzer, M.; Helus, F.; Layer, K.; Sinn, H.J.; Ostertag, H.

    1988-02-01

    The tissue uptake of (/sup 13/N)glutamate (glu) was related to that of (/sup 11/C)butanol (but), a highly diffusible perfusion tracer. In 25 rats bearing Walker-256 carcinomas tumor-to-muscle glu uptake averaged 6.34 +/- 2.84 (s.d.) prior to interventions and the respective uptake of but was 6.79 +/- 3.08 (y = 0.03 + 0.94x). One hour after selective intraarterial administration of methotrexate (mtx), glu uptake fell by 47%, whereas blood flow remained within the pretreatment range (N = 9). Four hours after mtx, perfusion was reduced by approximately 40%, and 2 days later both perfusion and glu uptake reached extremely low levels. No significant difference in the effect of 10 and 50 mg/kg mtx was observed. Regional tissue mtx uptake estimations using /sup 77/Br-labeled bromomethotrexate did not reveal any significant uptake in muscle. The relationship between tumor-to-muscle uptake of glu and but (/sup 13/N//sup 11/C-index) was 0.94 +/- 0.015 (s.e.m., N = 25) before intervention. After methotrexate (1 hr, 4 hr, and 2 days) this index was 0.58 +/- 0.06 (N = 9), and 0.85 +/- 0.04 (N = 11) and 1.03 +/- 0.05 (N = 5), respectively. These values demonstrate an early mtx-induced uncoupling of glu uptake with respect to perfusion.

  10. Physiological and biochemical markers of alveolar epithelial barrier dysfunction in perfused human lungs

    PubMed Central

    Frank, James A.; Briot, Raphael; Lee, Jae Woo; Ishizaka, Akitoshi; Uchida, Tokujiro; Matthay, Michael A.

    2009-01-01

    To study air space fluid clearance (AFC) under conditions that resemble the clinical setting of pulmonary edema in patients, we developed a new perfused human lung preparation. We measured AFC in 20 human lungs rejected for transplantation and determined the contribution of AFC to lung fluid balance. AFC was then compared with air space and perfusate levels of a biological marker of epithelial injury. The majority of human lungs rejected for transplant had intact basal (75%) and β2-adrenergic agonist-stimulated (70%) AFC. For lungs with both basal and stimulated AFC, the basal AFC rate was 19 ± 10%/h, and the β2-adrenergic-stimulated AFC rate was 43 ± 13%/h. Higher rates of AFC were associated with less lung weight gain (Pearson coefficient −0.90, P < 0.0001). Air space and perfusate levels of the type I pneumocyte marker receptor for advanced glycation end products (RAGE) were threefold and sixfold higher, respectively, in lungs without basal AFC compared with lungs with AFC (P < 0.05). These data show that preserved AFC is a critical determinant of favorable lung fluid balance in the perfused human lung, raising the possibility that β2-agonist therapy to increase edema fluid clearance may be of value for patients with acute lung injury and pulmonary edema. Also, although additional studies are needed, a biological marker of alveolar epithelial injury may be useful clinically in predicting preserved AFC. PMID:17351061

  11. PROTOPLASMIC POTENTIALS IN HALICYSTIS : IV. VACUOLAR PERFUSION WITH ARTIFICIAL SAP AND SEA WATER.

    PubMed

    Blinks, L R

    1935-01-20

    Perfusion of the vacuole of living cells of Halicystis is described, the method employing two longitudinally fused capillaries as entrance and exit tubes. Natural sap, artificial sap, and sea water have been successfully perfused, with various additions and deficiencies, within the limits of physiological balance. In H. ovalis the P.D. remains positive and scarcely reduced in value when normal sea water, at pH 8.1, is perfused in the vacuole. In H. Osterhoutii the P.D. reverses in sign when the perfused solution has a higher pH than 6.5. In both cases a large P.D. persists when the solutions are the same on both sides of the protoplasm. In the absence of external gradients, there must be some internal gradient or asymmetry of the protoplasm itself to account for the P.D. Since appreciable currents are produced, there must be some metabolic activity as a source of energy. The higher normal P.D. in H. ovalis is not due to the higher KCl content of its sap (as earlier suggested by the author) since it persists nearly unchanged when sea water is substituted for sap. PMID:19872853

  12. Functional cluster analysis of CT perfusion maps: a new tool for diagnosis of acute stroke?

    PubMed

    Baumgartner, Christian; Gautsch, Kurt; Böhm, Christian; Felber, Stephan

    2005-09-01

    CT perfusion imaging constitutes an important contribution to the early diagnosis of acute stroke. Cerebral blood flow (CBF), cerebral blood volume (CBV) and time-to-peak (TTP) maps are used to estimate the severity of cerebral damage after acute ischemia. We introduce functional cluster analysis as a new tool to evaluate CT perfusion in order to identify normal brain, ischemic tissue and large vessels. CBF, CBV and TTP maps represent the basis for cluster analysis applying a partitioning (k-means) and density-based (density-based spatial clustering of applications with noise, DBSCAN) paradigm. In patients with transient ischemic attack and stroke, cluster analysis identified brain areas with distinct hemodynamic properties (gray and white matter) and segmented territorial ischemia. CBF, CBV and TTP values of each detected cluster were displayed. Our preliminary results indicate that functional cluster analysis of CT perfusion maps may become a helpful tool for the interpretation of perfusion maps and provide a rapid means for the segmentation of ischemic tissue. PMID:15827821

  13. Assessment of the myocardial perfusion pattern in patients with multivessel coronary artery disease

    SciTech Connect

    Iskandrian, A.S.; Hakki, A.H.; Segal, B.L.; Kane, S.A.; Amenta, A.

    1983-11-01

    A total of 42 symptomatic patients with coronary artery disease involving two or three vessels were studied using exercise thallium-201 myocardial scintigraphy. Qualitative analysis of the images predicted multivessel disease in 75% of the patients with two-vessel disease and in 82% of the patients with three-vessel disease. Quantitative analysis of the size of the perfusion defect indicated that approximately 40% of the left ventricular perimeter showed abnormal perfusion pattern during stress in these patients, and there was no significant difference in the size of the defect in patients with two-vessel disease or three-vessel disease (41 +/- 17% vs 42 +/- 14%, respectively, mean +/- SD). The exercise heart rate, exercise ECG response, and severity of narrowing did not correlate with the size of the perfusion defect. Patients with anterior infarction had larger defects in the distribution of the left anterior descending artery than those without infarction. Collaterals offered partial protection during exercise only when they were not jeopardized. This study confirms the value of qualitative analysis of exercise thallium-201 imaging in predicting multivessel disease, and describes a simple method of assessing the extent of perfusion abnormalities during stress in patients with multivessel disease. The results may be important in patient management and prognosis.

  14. Towards robust deconvolution of low-dose perfusion CT: sparse perfusion deconvolution using online dictionary learning.

    PubMed

    Fang, Ruogu; Chen, Tsuhan; Sanelli, Pina C

    2013-05-01

    Computed tomography perfusion (CTP) is an important functional imaging modality in the evaluation of cerebrovascular diseases, particularly in acute stroke and vasospasm. However, the post-processed parametric maps of blood flow tend to be noisy, especially in low-dose CTP, due to the noisy contrast enhancement profile and the oscillatory nature of the results generated by the current computational methods. In this paper, we propose a robust sparse perfusion deconvolution method (SPD) to estimate cerebral blood flow in CTP performed at low radiation dose. We first build a dictionary from high-dose perfusion maps using online dictionary learning and then perform deconvolution-based hemodynamic parameters estimation on the low-dose CTP data. Our method is validated on clinical data of patients with normal and pathological CBF maps. The results show that we achieve superior performance than existing methods, and potentially improve the differentiation between normal and ischemic tissue in the brain. PMID:23542422

  15. Towards robust deconvolution of low-dose perfusion CT: Sparse perfusion deconvolution using online dictionary learning

    PubMed Central

    Fang, Ruogu; Chen, Tsuhan; Sanelli, Pina C.

    2014-01-01

    Computed tomography perfusion (CTP) is an important functional imaging modality in the evaluation of cerebrovascular diseases, particularly in acute stroke and vasospasm. However, the post-processed parametric maps of blood flow tend to be noisy, especially in low-dose CTP, due to the noisy contrast enhancement profile and the oscillatory nature of the results generated by the current computational methods. In this paper, we propose a robust sparse perfusion deconvolution method (SPD) to estimate cerebral blood flow in CTP performed at low radiation dose. We first build a dictionary from high-dose perfusion maps using online dictionary learning and then perform deconvolution-based hemodynamic parameters estimation on the low-dose CTP data. Our method is validated on clinical data of patients with normal and pathological CBF maps. The results show that we achieve superior performance than existing methods, and potentially improve the differentiation between normal and ischemic tissue in the brain. PMID:23542422

  16. Dose reduction assessment in dynamic CT myocardial perfusion imaging in a porcine balloon-induced-ischemia model

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.

  17. CT Perfusion Dynamics of Intracranial Tuberculomas

    PubMed Central

    N., Jayakumar Peruvumba; Shivashankar, Ravishankar

    2015-01-01

    Aims To study perfusion characteristics of intracranial tuberculomas and analyze changes with anti tubercular treatment. Materials and Methods Nineteen patients of histologically proven intracranial tuberculomas were included in the study of which 9 were not on antitubercular treatment and ten were on antitubercular treatment (6 patients on treatment for less than 2 months and 4 were more than 6 months). All patients underwent CT perfusion (CTP) and CTP parameters like rCBV and rCBF were obtained from entire lesion, center and capsule of lesions and compared. Results CTP parameters like rCBF and rCBV were significantly low in all the three ROIs in the group not on treatment compared to that of on treatment ; rCBF and rCBV of entire lesion (p=0.018 and p=0.005 respectively), capsule (p=0.045 and p=0.010 respectively) and center of the lesion (p=0.020 and p=0.009) respectively). Tuberculomas on antitubercular treatment of more than six months showed reduced rCBF and rCBV in entire lesion (p=0.01 & p=0.01 respectively), capsule (p=0.04 & p=0.03 respectively) and center (p=0.08 & p=0.05 respectively) compared to those on treatment for less than two months. Similarly tuberculomas on treatment for six months did not show significant difference in rCBF and rCBV compared to tuberculomas who were not on treatment. Tuberculomas on treatment for less than two months showed statistically increased rCBF and rCBV in entire lesion (p=0.01 & p=0.04 respectively), capsule (p=0.03 & p=0.01 respectively) and center (p= 0.03 &=0.01) compared to those not on treatment. Conclusion Intracranial tuberculomas not on treatment and those on treatment for around six months show low perfusion and tuberculomas on treatment for less than two months show high perfusion. These findings suggest that serial perfusion profiles of tuberculomas on treatment could possibly be seen as surrogate markers of response to treatment. PMID:26155528

  18. Valuing Essays: Essaying Values

    ERIC Educational Resources Information Center

    Badley, Graham

    2010-01-01

    The essay regularly comes under attack. It is criticised for being rigidly linear rather than flexible and reflective. I first challenge this view by examining reasons why the essay should be valued as an important genre. Secondly, I propose that in using the essay form students and academics necessarily exemplify their own critical values. Essays…

  19. MO-G-18C-05: Real-Time Prediction in Free-Breathing Perfusion MRI

    SciTech Connect

    Song, H; Liu, W; Ruan, D; Jung, S; Gach, M

    2014-06-15

    Purpose: The aim is to minimize frame-wise difference errors caused by respiratory motion and eliminate the need for breath-holds in magnetic resonance imaging (MRI) sequences with long acquisitions and repeat times (TRs). The technique is being applied to perfusion MRI using arterial spin labeling (ASL). Methods: Respiratory motion prediction (RMP) using navigator echoes was implemented in ASL. A least-square method was used to extract the respiratory motion information from the 1D navigator. A generalized artificial neutral network (ANN) with three layers was developed to simultaneously predict 10 time points forward in time and correct for respiratory motion during MRI acquisition. During the training phase, the parameters of the ANN were optimized to minimize the aggregated prediction error based on acquired navigator data. During realtime prediction, the trained ANN was applied to the most recent estimated displacement trajectory to determine in real-time the amount of spatial Results: The respiratory motion information extracted from the least-square method can accurately represent the navigator profiles, with a normalized chi-square value of 0.037±0.015 across the training phase. During the 60-second training phase, the ANN successfully learned the respiratory motion pattern from the navigator training data. During real-time prediction, the ANN received displacement estimates and predicted the motion in the continuum of a 1.0 s prediction window. The ANN prediction was able to provide corrections for different respiratory states (i.e., inhalation/exhalation) during real-time scanning with a mean absolute error of < 1.8 mm. Conclusion: A new technique enabling free-breathing acquisition during MRI is being developed. A generalized ANN development has demonstrated its efficacy in predicting a continuum of motion profile for volumetric imaging based on navigator inputs. Future work will enhance the robustness of ANN and verify its effectiveness with human

  20. Measurement of continuous distributions of ventilation-perfusion ratios - Theory

    NASA Technical Reports Server (NTRS)

    Wagner, P. D.; Saltzman, H. A.; West, J. B.

    1974-01-01

    The resolution of the technique considered is sufficient to describe smooth distributions containing blood flow to unventilated regions (shunt), ventilation to unperfused regions (dead space), and up to three additional modes over the range of finite ventilation-perfusion ratios. In particular, areas whose ventilation-perfusion ratios are low can be separated from unventilated regions and those whose ventilation-perfusion ratios are high can similarly be distinguished from unperfused areas.

  1. Scintigraphic perfusion patterns in patients with diffuse lung disease

    SciTech Connect

    Newman, G.E.; Sullivan, D.C.; Gottschalk, A.; Putman, C.E.

    1982-04-01

    Perfusion scintigrams of 55 patients with radiographic evidence of diffuse lung disease were reviewed. Thirty-nine had acute and/or chronic changes caused by congestive heart failure, and 16 had diffuse reticulonodular disease. A normal or near-normal perfusion pattern was seen in 40/55 (73%), and this finding was equally common in the two groups. The authors conclude that perfusion scintigraphy is useful in excluding pulmonary embolism in patients with radiographic evidence of diffuse, symmetrical lung disease.

  2. A method of thymic perfusion and its evaluation

    PubMed Central

    Ekwueme, O.

    1973-01-01

    The development and evaluation of a method of isolated ex vivo perfusion of the rabbit thymus using diluted autologous blood is described. The data indicate that the viability of the preparation is maintained at a satisfactory level during the period of perfusion. These results suggest that the isolated perfused thymus would be a useful new approach to studies of thymus function. ImagesFig. 2Fig. 8Fig. 9Fig. 10Fig. 11 PMID:4747584

  3. Perfusion Scintigraphy and Patient Selection for Lung Volume Reduction Surgery

    PubMed Central

    Chandra, Divay; Lipson, David A.; Hoffman, Eric A.; Hansen-Flaschen, John; Sciurba, Frank C.; DeCamp, Malcolm M.; Reilly, John J.; Washko, George R.

    2010-01-01

    Rationale: It is unclear if lung perfusion can predict response to lung volume reduction surgery (LVRS). Objectives: To study the role of perfusion scintigraphy in patient selection for LVRS. Methods: We performed an intention-to-treat analysis of 1,045 of 1,218 patients enrolled in the National Emphysema Treatment Trial who were non–high risk for LVRS and had complete perfusion scintigraphy results at baseline. The median follow-up was 6.0 years. Patients were classified as having upper or non–upper lobe–predominant emphysema on visual examination of the chest computed tomography and high or low exercise capacity on cardiopulmonary exercise testing at baseline. Low upper zone perfusion was defined as less than 20% of total lung perfusion distributed to the upper third of both lungs as measured on perfusion scintigraphy. Measurements and Main Results: Among 284 of 1,045 patients with upper lobe–predominant emphysema and low exercise capacity at baseline, the 202 with low upper zone perfusion had lower mortality with LVRS versus medical management (risk ratio [RR], 0.56; P = 0.008) unlike the remaining 82 with high perfusion where mortality was unchanged (RR, 0.97; P = 0.62). Similarly, among 404 of 1,045 patients with upper lobe–predominant emphysema and high exercise capacity, the 278 with low upper zone perfusion had lower mortality with LVRS (RR, 0.70; P = 0.02) unlike the remaining 126 with high perfusion (RR, 1.05; P = 1.00). Among the 357 patients with non–upper lobe–predominant emphysema (75 with low and 282 with high exercise capacity) there was no improvement in survival with LVRS and measurement of upper zone perfusion did not contribute new prognostic information. Conclusions: Compared with optimal medical management, LVRS reduces mortality in patients with upper lobe–predominant emphysema when there is low rather than high perfusion to the upper lung. PMID:20538961

  4. Clock time is absolute and universal

    NASA Astrophysics Data System (ADS)

    Shen, Xinhang

    2015-09-01

    A critical error is found in the Special Theory of Relativity (STR): mixing up the concepts of the STR abstract time of a reference frame and the displayed time of a physical clock, which leads to use the properties of the abstract time to predict time dilation on physical clocks and all other physical processes. Actually, a clock can never directly measure the abstract time, but can only record the result of a physical process during a period of the abstract time such as the number of cycles of oscillation which is the multiplication of the abstract time and the frequency of oscillation. After Lorentz Transformation, the abstract time of a reference frame expands by a factor gamma, but the frequency of a clock decreases by the same factor gamma, and the resulting multiplication i.e. the displayed time of a moving clock remains unchanged. That is, the displayed time of any physical clock is an invariant of Lorentz Transformation. The Lorentz invariance of the displayed times of clocks can further prove within the framework of STR our earth based standard physical time is absolute, universal and independent of inertial reference frames as confirmed by both the physical fact of the universal synchronization of clocks on the GPS satellites and clocks on the earth, and the theoretical existence of the absolute and universal Galilean time in STR which has proved that time dilation and space contraction are pure illusions of STR. The existence of the absolute and universal time in STR has directly denied that the reference frame dependent abstract time of STR is the physical time, and therefore, STR is wrong and all its predictions can never happen in the physical world.

  5. Achieving Climate Change Absolute Accuracy in Orbit

    NASA Technical Reports Server (NTRS)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; Bowman, K.; Brindley, H.; Butler, J. J.; Collins, W.; Dykema, J. A.; Doelling, D. R.; Feldman, D. R.; Fox, N.; Huang, X.; Holz, R.; Huang, Y.; Jennings, D.; Jin, Z.; Johnson, D. G.; Jucks, K.; Kato, S.; Kratz, D. P.; Liu, X.; Lukashin, C.; Mannucci, A. J.; Phojanamongkolkij, N.; Roithmayr, C. M.; Sandford, S.; Taylor, P. C.; Xiong, X.

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  6. An absolute radius scale for Saturn's rings

    NASA Technical Reports Server (NTRS)

    Nicholson, Philip D.; Cooke, Maren L.; Pelton, Emily

    1990-01-01

    Radio and stellar occultation observations of Saturn's rings made by the Voyager spacecraft are discussed. The data reveal systematic discrepancies of almost 10 km in some parts of the rings, limiting some of the investigations. A revised solution for Saturn's rotation pole has been proposed which removes the discrepancies between the stellar and radio occultation profiles. Corrections to previously published radii vary from -2 to -10 km for the radio occultation, and +5 to -6 km for the stellar occultation. An examination of spiral density waves in the outer A Ring supports that the revised absolute radii are in error by no more than 2 km.

  7. Characterization of the DARA solar absolute radiometer

    NASA Astrophysics Data System (ADS)

    Finsterle, W.; Suter, M.; Fehlmann, A.; Kopp, G.

    2011-12-01

    The Davos Absolute Radiometer (DARA) prototype is an Electrical Substitution Radiometer (ESR) which has been developed as a successor of the PMO6 type on future space missions and ground based TSI measurements. The DARA implements an improved thermal design of the cavity detector and heat sink assembly to minimize air-vacuum differences and to maximize thermal symmetry of measuring and compensating cavity. The DARA also employs an inverted viewing geometry to reduce internal stray light. We will report on the characterization and calibration experiments which were carried out at PMOD/WRC and LASP (TRF).

  8. Absolute calibration of the Auger fluorescence detectors

    SciTech Connect

    Bauleo, P.; Brack, J.; Garrard, L.; Harton, J.; Knapik, R.; Meyhandan, R.; Rovero, A.C.; Tamashiro, A.; Warner, D.

    2005-07-01

    Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the combined effects of all detector components in a single measurement. The calibrated 2.5 m diameter light source fills the aperture, providing uniform illumination to each pixel. The known flux from the light source and the response of the acquisition system give the required calibration for each pixel. In the lab, light source uniformity is studied using CCD images and the intensity is measured relative to NIST-calibrated photodiodes. Overall uncertainties are presently 12%, and are dominated by systematics.

  9. Absolute angular positioning in ultrahigh vacuum

    SciTech Connect

    Schief, H.; Marsico, V.; Kern, K.

    1996-05-01

    Commercially available angular resolvers, which are routinely used in machine tools and robotics, are modified and adapted to be used under ultrahigh-vacuum (UHV) conditions. They provide straightforward and reliable measurements of angular positions for any kind of UHV sample manipulators. The corresponding absolute reproducibility is on the order of 0.005{degree}, whereas the relative resolution is better than 0.001{degree}, as demonstrated by high-resolution helium-reflectivity measurements. The mechanical setup and possible applications are discussed. {copyright} {ital 1996 American Institute of Physics.}

  10. Absolute Priority for a Vehicle in VANET

    NASA Astrophysics Data System (ADS)

    Shirani, Rostam; Hendessi, Faramarz; Montazeri, Mohammad Ali; Sheikh Zefreh, Mohammad

    In today's world, traffic jams waste hundreds of hours of our life. This causes many researchers try to resolve the problem with the idea of Intelligent Transportation System. For some applications like a travelling ambulance, it is important to reduce delay even for a second. In this paper, we propose a completely infrastructure-less approach for finding shortest path and controlling traffic light to provide absolute priority for an emergency vehicle. We use the idea of vehicular ad-hoc networking to reduce the imposed travelling time. Then, we simulate our proposed protocol and compare it with a centrally controlled traffic light system.

  11. Extracorporeal Free Flap Perfusion in Case of Prolonged Ischemia Time

    PubMed Central

    Präbst, K.; Beier, J. P.; Meyer, A.; Horch, R. E.

    2016-01-01

    Summary: In free flap surgery, a clinically established concept still has to be found for the reduction of ischemia-related cell damage in the case of prolonged ischemia. Although promising results using extracorporeal free flap perfusion in the laboratory have been published in the past, until now this concept has not yet paved its way into clinical routine. This might be due to the complexity of perfusion systems and a lack of standardized tools. Here, we want to present the results of the first extracorporeal free flap perfusion in a clinical setting using a simple approach without the application of a complex perfusion machinery. PMID:27200244

  12. New imaging technology: measurement of myocardial perfusion by contrast echocardiography

    NASA Technical Reports Server (NTRS)

    Rubin, D. N.; Thomas, J. D.

    2000-01-01

    Myocardial perfusion imaging has long been a goal for the non-invasive echocardiographic assessment of the heart. However, many factors at play in perfusion imaging have made this goal elusive. Harmonic imaging and triggered imaging with newer contrast agents have made myocardial perfusion imaging potentially practical in the very near future. The application of indicator dilution theory to the coronary circulation and bubble contrast agents is fraught with complexities and sources of error. Therefore, quantification of myocardial perfusion by non-invasive echocardiographic imaging requires further investigation in order to make this technique clinically viable.

  13. Perfusion CT imaging of the liver: review of clinical applications

    PubMed Central

    Oğul, Hayri; Kantarcı, Mecit; Genç, Berhan; Pirimoğlu, Berhan; Çullu, Neşat; Kızrak, Yeşim; Yılmaz, Ömer; Karabulut, Nevzat

    2014-01-01

    Perfusion computed tomography (CT) has a great potential for determining hepatic and portal blood flow; it offers the advantages of quantitative determination of lesion hemodynamics, distinguishing malignant and benign processes, as well as providing morphological data. Many studies have reported the use of this method in the assessment of hepatic tumors, hepatic fibrosis associated with chronic liver disease, treatment response following radiotherapy and chemotherapy, and hepatic perfusion changes after radiological or surgical interventions. The main goal of liver perfusion imaging is to improve the accuracy in the characterization of liver disorders. In this study, we reviewed the clinical application of perfusion CT in various hepatic diseases. PMID:24834487

  14. Radionuclide Tracers for Myocardial Perfusion Imaging and Blood Flow Quantification.

    PubMed

    deKemp, Robert A; Renaud, Jennifer M; Klein, Ran; Beanlands, Rob S B

    2016-02-01

    Myocardial perfusion imaging is performed most commonly using Tc-99m-sestamibi or tetrofosmin SPECT as well as Rb-82-rubidium or N-13-ammonia PET. Diseased-to-normal tissue contrast is determined by the tracer retention fraction, which decreases nonlinearly with flow. Reduced tissue perfusion results in reduced tracer retention, but the severity of perfusion defects is typically underestimated by 20% to 40%. Compared to SPECT, retention of the PET tracers is more linearly related to flow, and therefore, the perfusion defects are measured more accurately using N-13-ammonia or Rb-82. PMID:26590778

  15. SU-E-I-36: A KWIC and Dirty Look at Dose Savings and Perfusion Metrics in Simulated CT Neuro Perfusion Exams

    SciTech Connect

    Hoffman, J; Martin, T; Young, S; McNitt-Gray, M; Wang, D

    2015-06-15

    Purpose: CT neuro perfusion scans are one of the highest dose exams. Methods to reduce dose include decreasing the number of projections acquired per gantry rotation, however conventional reconstruction of such scans leads to sampling artifacts. In this study we investigated a projection view-sharing reconstruction algorithm used in dynamic MRI – “K-space Weighted Image Contrast” (KWIC) – applied to simulated perfusion exams and evaluated dose savings and impacts on perfusion metrics. Methods: A FORBILD head phantom containing simulated time-varying objects was developed and a set of parallel-beam CT projection data was created. The simulated scans were 60 seconds long, 1152 projections per turn, with a rotation time of one second. No noise was simulated. 5mm, 10mm, and 50mm objects were modeled in the brain. A baseline, “full dose” simulation used all projections and reduced dose cases were simulated by downsampling the number of projections per turn from 1152 to 576 (50% dose), 288 (25% dose), and 144 (12.5% dose). KWIC was further evaluated at 72 projections per rotation (6.25%). One image per second was reconstructed using filtered backprojection (FBP) and KWIC. KWIC reconstructions utilized view cores of 36, 72, 144, and 288 views and 16, 8, 4, and 2 subapertures respectively. From the reconstructed images, time-to-peak (TTP), cerebral blood flow (CBF) and the FWHM of the perfusion curve were calculated and compared against reference values from the full-dose FBP data. Results: TTP, CBF, and the FWHM were unaffected by dose reduction (to 12.5%) and reconstruction method, however image quality was improved when using KWIC. Conclusion: This pilot study suggests that KWIC preserves image quality and perfusion metrics when under-sampling projections and that the unique contrast weighting of KWIC could provided substantial dose-savings for perfusion CT scans. Evaluation of KWIC in clinical CT data will be performed in the near future. R01 EB014922, NCI

  16. Absolute Temperature Monitoring Using RF Radiometry in the MRI Scanner.

    PubMed

    El-Sharkawy, Abdel-Monem M; Sotiriadis, Paul P; Bottomley, Paul A; Atalar, Ergin

    2006-11-01

    Temperature detection using microwave radiometry has proven value for noninvasively measuring the absolute temperature of tissues inside the body. However, current clinical radiometers operate in the gigahertz range, which limits their depth of penetration. We have designed and built a noninvasive radiometer which operates at radio frequencies (64 MHz) with ∼100-kHz bandwidth, using an external RF loop coil as a thermal detector. The core of the radiometer is an accurate impedance measurement and automatic matching circuit of 0.05 Ω accuracy to compensate for any load variations. The radiometer permits temperature measurements with accuracy of ±0.1°K, over a tested physiological range of 28° C-40° C in saline phantoms whose electric properties match those of tissue. Because 1.5 T magnetic resonance imaging (MRI) scanners also operate at 64 MHz, we demonstrate the feasibility of integrating our radiometer with an MRI scanner to monitor RF power deposition and temperature dosimetry, obtaining coarse, spatially resolved, absolute thermal maps in the physiological range. We conclude that RF radiometry offers promise as a direct, noninvasive method of monitoring tissue heating during MRI studies and thereby providing an independent means of verifying patient-safe operation. Other potential applications include titration of hyper- and hypo-therapies. PMID:18026562

  17. Standardization of the cumulative absolute velocity. Final report

    SciTech Connect

    O`Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ``A Criterion for Determining Exceedance of the Operating Basis Earthquake,`` was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set.

  18. Absolute surface energies, fracture toughness, and cracking in nitrides

    NASA Astrophysics Data System (ADS)

    Dreyer, Cyrus E.; Janotti, Anderson; van de Walle, Chris G.

    2014-03-01

    Growth of high quality single crystals and epitaxial layers of GaN is critical for producing high-efficiency optoelectronic and power electronic devices. One of the fundamental material properties that govern growth of single crystals is the absolute surface energy of the crystallographic planes. Knowledge of these energies is required to understand and optimize growth rates of different facets in GaN, and provide fracture toughnesses for brittle fracture. By means of hybrid functional calculations, we have determined absolute surface energies for the non-polar {11-20} a and {10-10} m planes, and approximated values for polar (0001) + c and (000-1) - c planes in wurtzite GaN. For all surfaces, we consider low-energy bare and hydrogenated reconstructions under a variety of conditions relevant to experimental growth techniques. We find that the energies of the m and a planes are similar, and constant over the range of conditions studied. In contrast, the energies of the polar planes are strongly condition dependent. Even so, we find that the + c polar plane is systematically lower in energy than the - c plane. We have used our surface energies to determine brittle fracture toughnesses in AlN and GaN, as well as the critical thickness for cracking of AlGaN on GaN.

  19. Simulation of absolute amplitudes of ultrasound signals using equivalent circuits.

    PubMed

    Johansson, Jonny; Martinsson, Pär-Erik; Delsing, Jerker

    2007-10-01

    Equivalent circuits for piezoelectric devices and ultrasonic transmission media can be used to cosimulate electronics and ultrasound parts in simulators originally intended for electronics. To achieve efficient system-level optimization, it is important to simulate correct, absolute amplitude of the ultrasound signal in the system, as this determines the requirements on the electronics regarding dynamic range, circuit noise, and power consumption. This paper presents methods to achieve correct, absolute amplitude of an ultrasound signal in a simulation of a pulse-echo system using equivalent circuits. This is achieved by taking into consideration loss due to diffraction and the effect of the cable that connects the electronics and the piezoelectric transducer. The conductive loss in the transmission line that models the propagation media of the ultrasound pulse is used to model the loss due to diffraction. Results show that the simulated amplitude of the echo follows measured values well in both near and far fields, with an offset of about 10%. The use of a coaxial cable introduces inductance and capacitance that affect the amplitude of a received echo. Amplitude variations of 60% were observed when the cable length was varied between 0.07 m and 2.3 m, with simulations predicting similar variations. The high precision in the achieved results show that electronic design and system optimization can rely on system simulations alone. This will simplify the development of integrated electronics aimed at ultrasound systems. PMID:18019234

  20. Determination of the absolute contours of optical flats

    NASA Technical Reports Server (NTRS)

    Primak, W.

    1969-01-01

    Emersons procedure is used to determine true absolute contours of optical flats. Absolute contours of standard flats are determined and a comparison is then made between standard and unknown flats. Contour differences are determined by deviation of Fizeau fringe.

  1. Modeling laser speckle imaging of perfusion in the skin (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Regan, Caitlin; Hayakawa, Carole K.; Choi, Bernard

    2016-02-01

    Laser speckle imaging (LSI) enables visualization of relative blood flow and perfusion in the skin. It is frequently applied to monitor treatment of vascular malformations such as port wine stain birthmarks, and measure changes in perfusion due to peripheral vascular disease. We developed a computational Monte Carlo simulation of laser speckle contrast imaging to quantify how tissue optical properties, blood vessel depths and speeds, and tissue perfusion affect speckle contrast values originating from coherent excitation. The simulated tissue geometry consisted of multiple layers to simulate the skin, or incorporated an inclusion such as a vessel or tumor at different depths. Our simulation used a 30x30mm uniform flat light source to optically excite the region of interest in our sample to better mimic wide-field imaging. We used our model to simulate how dynamically scattered photons from a buried blood vessel affect speckle contrast at different lateral distances (0-1mm) away from the vessel, and how these speckle contrast changes vary with depth (0-1mm) and flow speed (0-10mm/s). We applied the model to simulate perfusion in the skin, and observed how different optical properties, such as epidermal melanin concentration (1%-50%) affected speckle contrast. We simulated perfusion during a systolic forearm occlusion and found that contrast decreased by 35% (exposure time = 10ms). Monte Carlo simulations of laser speckle contrast give us a tool to quantify what regions of the skin are probed with laser speckle imaging, and measure how the tissue optical properties and blood flow affect the resulting images.

  2. A spatially-distributed computational model to quantify behaviour of contrast agents in MR perfusion imaging

    PubMed Central

    Cookson, A.N.; Lee, J.; Michler, C.; Chabiniok, R.; Hyde, E.; Nordsletten, D.; Smith, N.P.

    2014-01-01

    Contrast agent enhanced magnetic resonance (MR) perfusion imaging provides an early, non-invasive indication of defects in the coronary circulation. However, the large variation of contrast agent properties, physiological state and imaging protocols means that optimisation of image acquisition is difficult to achieve. This situation motivates the development of a computational framework that, in turn, enables the efficient mapping of this parameter space to provide valuable information for optimisation of perfusion imaging in the clinical context. For this purpose a single-compartment porous medium model of capillary blood flow is developed which is coupled with a scalar transport model, to characterise the behaviour of both blood-pool and freely-diffusive contrast agents characterised by their ability to diffuse through the capillary wall into the extra-cellular space. A parameter space study is performed on the nondimensionalised equations using a 2D model for both healthy and diseased myocardium, examining the sensitivity of system behaviour to Peclet number, Damköhler number (Da), diffusivity ratio and fluid porosity. Assuming a linear MR signal response model, sample concentration time series data are calculated, and the sensitivity of clinically-relevant properties of these signals to the model parameters is quantified. Both upslope and peak values display significant non-monotonic behaviour with regard to the Damköhler number, with these properties showing a high degree of sensitivity in the parameter range relevant to contrast agents currently in use. However, the results suggest that signal upslope is the more robust and discerning metric for perfusion quantification, in particular for correlating with perfusion defect size. Finally, the results were examined in the context of nonlinear signal response, flow quantification via Fermi deconvolution and perfusion reserve index, which demonstrated that there is no single best set of contrast agent parameters

  3. Correlation of CT perfusion and CT volumetry in patients with Alzheimer’s disease

    PubMed Central

    Czarnecka, Anna; Zimny, Anna; Sąsiadek, Marek

    2010-01-01

    Summary Background: Both brain atrophy and decrease of perfusion are observed in dementive diseases. The aim of the study was to correlate the results of brain perfusion CT (pCT) and CT volumetry in patients with Alzheimer’s disease (AD). Material/Methods: Forty-eight patients with AD (mean age of 71.3 years) underwent brain pCT and CT volumetry. The pCT was performed at the level of basal ganglia after the injection of contrast medium (50 ml, 4 ml/sec.) with serial scanning (delay 7 sec, 50 scans, 1 scan/sec). Volumetric measurements were carried out on the basis of source images, with the use of a dedicated CT software combined with manual outlining of the regions of interest in extracerebral and intraventricular CSF spaces. Perfusion parameters of the cerebral blood flow (CBF) and cerebral blood volume (CBV) from the grey matter of frontal and temporal as well as basal ganglia were compared statistically with the volumetric measurements of frontal and temporal cortical atrophy as well as subcortical atrophy. Results: A statistically significant positive correlation was found between the values of CBF and CBV in the basal ganglia and the volumes of the lateral and third ventricles. The comparison of CBF and CBV results with the volumetric measurements in the areas of the frontal and temporal lobes showed mostly negative correlations, but none of them was of statistical significance. Conclusions: In patients with AD, the degree of cortical atrophy is not correlated with the decrease of perfusion in the grey matter and subcortical atrophy is not correlated with the decrease of perfusion in the basal ganglia region. It suggests that functional and structural changes in AD are not related to each other. PMID:22802771

  4. Perfusion deficits in patients with mild traumatic brain injury characterized by dynamic susceptibility contrast MRI.

    PubMed

    Liu, Wei; Wang, Binquan; Wolfowitz, Rachel; Yeh, Ping-Hong; Nathan, Dominic E; Graner, John; Tang, Haiying; Pan, Hai; Harper, Jamie; Pham, Dzung; Oakes, Terrence R; French, Louis M; Riedy, Gerard

    2013-06-01

    Perfusion deficits in patients with mild traumatic brain injury (TBI) from a military population were characterized by dynamic susceptibility contrast perfusion imaging. Relative cerebral blood flow (rCBF) was calculated by a model-independent deconvolution approach from the tracer concentration curves following a bolus injection of gadolinium diethylenetriaminepentaacetate (Gd-DTPA) using both manually and automatically selected arterial input functions (AIFs). Linear regression analysis of the mean values of rCBF from selected regions of interest showed a very good agreement between the two approaches, with a regression coefficient of R = 0.88 and a slope of 0.88. The Bland-Altman plot also illustrated the good agreement between the two approaches, with a mean difference of 0.6 ± 12.4 mL/100 g/min. Voxelwise analysis of rCBF maps from both approaches demonstrated multiple clusters of decreased perfusion (p < 0.01) in the cerebellum, cuneus, cingulate and temporal gyrus in the group with mild TBI relative to the controls. MRI perfusion deficits in the cerebellum and anterior cingulate also correlated (p < 0.01) with neurocognitive results, including the mean reaction time in the Automated Neuropsychological Assessment Metrics and commission error and detection T-scores in the Continuous Performance Test, as well as neurobehavioral scores in the Post-traumatic Stress Disorder Checklist-Civilian Version. In conclusion, rCBF calculated using AIFs selected from an automated approach demonstrated a good agreement with the corresponding results using manually selected AIFs. Group analysis of patients with mild TBI from a military population demonstrated scattered perfusion deficits, which showed significant correlations with measures of verbal memory, speed of reaction time and self-report of stress symptoms. PMID:23456696

  5. Transient absolute robustness in stochastic biochemical networks.

    PubMed

    Enciso, German A

    2016-08-01

    Absolute robustness allows biochemical networks to sustain a consistent steady-state output in the face of protein concentration variability from cell to cell. This property is structural and can be determined from the topology of the network alone regardless of rate parameters. An important question regarding these systems is the effect of discrete biochemical noise in the dynamical behaviour. In this paper, a variable freezing technique is developed to show that under mild hypotheses the corresponding stochastic system has a transiently robust behaviour. Specifically, after finite time the distribution of the output approximates a Poisson distribution, centred around the deterministic mean. The approximation becomes increasingly accurate, and it holds for increasingly long finite times, as the total protein concentrations grow to infinity. In particular, the stochastic system retains a transient, absolutely robust behaviour corresponding to the deterministic case. This result contrasts with the long-term dynamics of the stochastic system, which eventually must undergo an extinction event that eliminates robustness and is completely different from the deterministic dynamics. The transiently robust behaviour may be sufficient to carry out many forms of robust signal transduction and cellular decision-making in cellular organisms. PMID:27581485

  6. Absolute Electron Extraction Efficiency of Liquid Xenon

    NASA Astrophysics Data System (ADS)

    Kamdin, Katayun; Mizrachi, Eli; Morad, James; Sorensen, Peter

    2016-03-01

    Dual phase liquid/gas xenon time projection chambers (TPCs) currently set the world's most sensitive limits on weakly interacting massive particles (WIMPs), a favored dark matter candidate. These detectors rely on extracting electrons from liquid xenon into gaseous xenon, where they produce proportional scintillation. The proportional scintillation from the extracted electrons serves to internally amplify the WIMP signal; even a single extracted electron is detectable. Credible dark matter searches can proceed with electron extraction efficiency (EEE) lower than 100%. However, electrons systematically left at the liquid/gas boundary are a concern. Possible effects include spontaneous single or multi-electron proportional scintillation signals in the gas, or charging of the liquid/gas interface or detector materials. Understanding EEE is consequently a serious concern for this class of rare event search detectors. Previous EEE measurements have mostly been relative, not absolute, assuming efficiency plateaus at 100%. I will present an absolute EEE measurement with a small liquid/gas xenon TPC test bed located at Lawrence Berkeley National Laboratory.

  7. Sentinel-2/MSI absolute calibration: first results

    NASA Astrophysics Data System (ADS)

    Lonjou, V.; Lachérade, S.; Fougnie, B.; Gamet, P.; Marcq, S.; Raynaud, J.-L.; Tremas, T.

    2015-10-01

    Sentinel-2 is an optical imaging mission devoted to the operational monitoring of land and coastal areas. It is developed in partnership between the European Commission and the European Space Agency. The Sentinel-2 mission is based on a satellites constellation deployed in polar sun-synchronous orbit. It will offer a unique combination of global coverage with a wide field of view (290km), a high revisit (5 days with two satellites), a high resolution (10m, 20m and 60m) and multi-spectral imagery (13 spectral bands in visible and shortwave infra-red domains). CNES is involved in the instrument commissioning in collaboration with ESA. This paper reviews all the techniques that will be used to insure an absolute calibration of the 13 spectral bands better than 5% (target 3%), and will present the first results if available. First, the nominal calibration technique, based on an on-board sun diffuser, is detailed. Then, we show how vicarious calibration methods based on acquisitions over natural targets (oceans, deserts, and Antarctica during winter) will be used to check and improve the accuracy of the absolute calibration coefficients. Finally, the verification scheme, exploiting photometer in-situ measurements over Lacrau plain, is described. A synthesis, including spectral coherence, inter-methods agreement and temporal evolution, will conclude the paper.

  8. Absolute Spectrophotometry of 237 Open Cluster Stars

    NASA Astrophysics Data System (ADS)

    Clampitt, L.; Burstein, D.

    1994-12-01

    We present absolute spectrophotometry of 237 stars in 7 nearby open clusters: Hyades, Pleiades, Alpha Persei, Praesepe, Coma Berenices, IC 4665, and M 39. The observations were taken using the Wampler single-channel scanner (Wampler 1966) on the Crossley 0.9m telescope at Lick Observatory from July 1973 through December 1974. 21 bandpasses spanning the spectral range 3500 Angstroms to 7780 Angstroms were observed for each star, with bandwiths ranging from 32Angstroms to 64 Angstroms. Data are standardized to the Hayes--Latham (1975) system. Our measurements are compared to filter colors on the Johnson BV, Stromgren ubvy, and Geneva U V B_1 B_2 V_1 G systems, as well as to spectrophotometry of a few stars published by Gunn, Stryker & Tinsley and in the Spectrophotometric Standards Catalog (Adelman; as distributed by the NSSDC). Both internal and external comparisons to the filter systems indicate a formal statistical accuracy per bandpass of 0.01 to 0.02 mag, with apparent larger ( ~ 0.03 mag) differences in absolute calibration between this data set and existing spectrophotometry. These data will comprise part of the spectrophotometry that will be used to calibrate the Beijing-Arizona-Taipei-Connecticut Color Survey of the Sky (see separate paper by Burstein et al. at this meeting).

  9. 20 CFR 404.1205 - Absolute coverage groups.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Absolute coverage groups. 404.1205 Section... INSURANCE (1950- ) Coverage of Employees of State and Local Governments What Groups of Employees May Be Covered § 404.1205 Absolute coverage groups. (a) General. An absolute coverage group is a...

  10. The effects of perfusion conditions on melphalan distribution in the isolated perfused rat hindlimb bearing a human melanoma xenograft.

    PubMed

    Wu, Z Y; Smithers, B M; Parsons, P G; Roberts, M S

    1997-01-01

    An isolated rat hindlimb perfusion model carrying xenografts of the human melanoma cell line MM96 was used to study the effects of perfusion conditions on melphalan distribution. Krebs-Henseleit buffer and Hartmann's solution containing 4.7% bovine serum albumin (BSA) or 2.8% dextran 40 were used as perfusates. Melphalan concentrations in perfusate, tumour nodules and normal tissues were measured using high-performance liquid chromatography (HPLC). Increasing the perfusion flow rates (from 4 to 8 ml min(-1)) resulted in higher tissue blood flow (determined with 51Cr-labelled microspheres) and melphalan uptake by tumour and normal tissues. The distribution of melphalan within tumour nodules and normal tissues was similar for both Krebs-Henseleit buffer and Hartmann's solution; however, tissue concentrations of melphalan were significantly higher for a perfusate containing 2.8% dextran 40 than for one containing 4.7% BSA. The melphalan concentration in the tumour was one-third of that found in the skin if the perfusate contained 4.7% BSA. In conclusion, this study has shown that a high perfusion flow enhances the delivery of melphalan into implanted tumour nodules and normal tissues, and a perfusate with low melphalan binding (no albumin) is preferred for maximum uptake of drug by the tumour. PMID:9099965

  11. Transient finite element analysis of thermal methods used to estimate SAR and blood flow in homogeneously and nonhomogeneously perfused tumour models.

    PubMed

    Wong, T Z; Mechling, J A; Jones, E L; Strohbehn, J W

    1988-01-01

    A two-dimensional time-dependent finite element model was developed to evaluate thermal techniques for estimating blood flow and specific absorption rate (SAR). In these computer simulations, homogeneously and nonhomogeneously perfused tumour models were heated by a 915 MHz interstitial microwave antenna array. Representative blood flow values were assigned within the tumour, and the applied SAR distribution was based on a previously developed antenna theory. SAR values were estimated from the power-on transient temperatures, and blood flow values were estimated from thermal clearance data after power was discontinued. These estimated parameters were then compared to the known 'true' blood flow and SAR values throughout the treatment region. SAR values could be predicted with reasonable accuracy throughout most of the heated region independent of local blood flow. For a homogeneous model, thermal clearance was found to yield reasonably accurate blood flow estimates at high perfusion rates and less accurate estimates at lower perfusion rates. However, for the inhomogeneous model, the blood perfusion estimates were generally poor, and an average blood flow value for the tumour was obtained with little ability to resolve the differences in perfusion between regions. Using temperatures observed early in the cool-down curve resulted in improved spatial resolution, but increased the contribution of thermal conduction to the blood flow estimates. A single time-constant exponential thermal decay curve was found to be a necessary but not sufficient condition for reliable blood flow estimates using this technique. PMID:3171254

  12. ROI for outlining an entire tumor is a reliable approach for quantification of lung cancer tumor vascular parameters using CT perfusion

    PubMed Central

    Ma, Ensen; Ren, An; Gao, Baoxiang; Yang, Minxing; Zhao, Qichao; Wang, Wu; Li, Kefeng

    2016-01-01

    Objective To investigate the effect of position and size of tumor region of interest (ROI) on the estimation of lung cancer vascular parameters using 256-slice computed tomography (CT) perfusion. Methods After institutional review board approval and written informed consent, 16 men and 11 women with lung cancer were enrolled in this CT perfusion study. Perfusion, blood volume, and peak enhancement were determined for 60 or 120 mm2 circular ROIs placed at the edge, center, and around (outlining) the visible tumor. Average values were obtained by performing ROI analysis twice by the same observers without any procedural changes. Results Perfusion, blood volume, and peak enhancement measurements were substantially higher at the edge than at the center for both 60 and 120 mm2 ROIs (all P<0.05). Measurements varied substantially depending on the ROI size. Perfusion, blood volume, and peak enhancement for the ROIs outlining tumor were intermediate between those at the tumor edge and center. There were significant correlations between median values and interquartile ranges as follows; perfusion (12.51 [7.91–28.10] mL⋅min−1⋅100 mL−1), blood volume (29.31 [21.82–37.65] mL⋅100 g−1), peak enhancement (12.93 [2.42–22.50]) for the ROIs outlining the tumor, and microvascular density ([19.43±8.78] vessels/0.74 mm2), respectively (r values were 0.732, 0.590, and 0.544 respectively, all P<0.05). Conclusion Spatial and size selection of ROI significantly affects CT perfusion analysis. ROI outlining of entire tumor provides efficient and reliable measurements for clinical assessment of lung cancer using CT perfusion. PMID:27175083

  13. Experimental glomerulonephritis in the isolated perfused rat kidney.

    PubMed Central

    Couser, W G; Steinmuller, D R; Stilmant, M M; Salant, D J; Lowenstein, L M

    1978-01-01

    The development of immune deposits on the subepithelial surface of the glomerular capillary wall was studied in isolated rat kidneys perfused at controlled perfusion pressure, pH, temperature, and flow rates with recirculating oxygenated perfusate containing bovine serum albumin (BSA) in buffer and sheep antibody to rat proximal tubular epithelial cell brush border antigen (Fx1A). Control kidney were perfused with equal concentrations of non-antibody immunoglobulin (Ig)G. Renal function was monitored by measuring inulin clearance, sodium reabsorption, and urine flow as well as BSA excretion and fractional clearance. Perfused kidneys were studied by light, immunofluorescence, and electron microscopy. All kidneys perfused with anti-Fx1A developed diffuse, finely granular deposits of IgG along the glomerular capillary wall by immunofluorescence. Electron microscopy revealed these deposits to be localized exclusively in the subepithelial space and slit pores. Similar deposits were produced in a nonrecirculating perfusion system, thereby excluding the formation of immune complexes in the perfusate caused by renal release of tubular antigen. Control kidneys perfused with nonantibody IgG did not develop glomerular immune deposits. Renal function and BSA excretion were the same in experimental and control kidneys. Glomerular deposits in antibody perfused kidneys were indistinguishable from deposits in rats injected with anti-Fx1A or immunized with Fx1A to produce autologous immune complex nephropathy. These studies demonstrate that subepithelial immune deposits can be produced in the isolated rat kidney by perfusion with specific antibody to Fx1A in the absence of circulating immune complexes. In this model deposits result from in situ complex formation rather than circulating immune complex deposition. Images PMID:372233

  14. In vivo assessment of myocardial perfusion and viability by kinetics of potassium-38

    SciTech Connect

    Bol, A.; Melin, J.A.; Wijns, W.

    1994-05-01

    To assess whether myocardial perfusion and viability could be estimated by dynamic K-38 (T1/2: 8 min) imaging with Positron Emission Tomography, closed chest dogs were studied after permanent (PERM; 8 studies) or during transient (TRANS; 7 studies) circumflex coronary occlusion. By using a two-compartment kinetic model, estimates of PET myocardial perfusion were compared to in vitro labeled microspheres (MS) myocardial blood flow (MBF; ml/min/100g). The backward rate of transport (k2) was also derived as a putative index of viability. Triphenyl tetrazolium chloride (TTC) staining was used to identify necrosis (TTC-) or viable tissue (TTC+). In the risk zone, MS-MBF ranged from 2 to 143 in 17 TTC- regions and from 6 to 48 in 12 TTC+ regions; K-38 MBF estimates correlated well with MS-MBF both in TTC- regions (MS-MBF : 37{plus_minus}43; y=1+1.2x; r=0.97) of PERM studies and in TTC+ regions (MS-MBF :28{plus_minus}13; y=7+0.69x; r=0.79) of TRANS studies. The backward rate of transport, k2 (min{sup -1}), was increased in 7/17 TTC-regions (5{plus_minus}8; n=17) and in none of the TTC+ regions (0.1{plus_minus}0.1). Thus, during experimental coronary occlusion, potassium-38 dynamic imaging provides a valuable estimate of absolute myocardial perfusion in low flow regions. Moreover, potassium-38 backdiffusion assessed by k2 might be a promising index of necrosis.

  15. Absolute Radiation Measurements in Earth and Mars Entry Conditions

    NASA Technical Reports Server (NTRS)

    Cruden, Brett A.

    2014-01-01

    This paper reports on the measurement of radiative heating for shock heated flows which simulate conditions for Mars and Earth entries. Radiation measurements are made in NASA Ames' Electric Arc Shock Tube at velocities from 3-15 km/s in mixtures of N2/O2 and CO2/N2/Ar. The technique and limitations of the measurement are summarized in some detail. The absolute measurements will be discussed in regards to spectral features, radiative magnitude and spatiotemporal trends. Via analysis of spectra it is possible to extract properties such as electron density, and rotational, vibrational and electronic temperatures. Relaxation behind the shock is analyzed to determine how these properties relax to equilibrium and are used to validate and refine kinetic models. It is found that, for some conditions, some of these values diverge from non-equilibrium indicating a lack of similarity between the shock tube and free flight conditions. Possible reasons for this are discussed.

  16. First derivative versus absolute spectral reflectance of citrus varieties

    NASA Astrophysics Data System (ADS)

    Blazquez, Carlos H.; Nigg, H. N.; Hedley, Lou E.; Ramos, L. E.; Sorrell, R. W.; Simpson, S. E.

    1996-06-01

    Spectral reflectance measurements from 400 to 800 nm were taken from immature and mature leaves of grapefruit ('McCarty' and 'Rio Red'), 'Minneola' tangelo, 'Satsuma' mandarin, 'Dancy' tangerine, 'Nagami' oval kumquat, and 'Valencia' sweet orange, at the Florida Citrus Arboretum, Division of Plant Industry, Winter Haven, Florida. Immature and mature leaves of 'Minneola' tangelo had greater percent reflectance in the 400 to 800 nm range than the other varieties and leaf ages measured. The slope of the citrus spectral curves in the 800 nm range was not as sharp as conventional spectrometers, but had a much higher reflectance value than those obtained with a DK-2 spectrometer. Statistical analyses of absolute spectral data yielded significant differences between mature and immature leaves and between varieties. First derivative data analyses did not yield significant differences between varieties.

  17. An absolute scale for measuring the utility of money

    NASA Astrophysics Data System (ADS)

    Thomas, P. J.

    2010-07-01

    Measurement of the utility of money is essential in the insurance industry, for prioritising public spending schemes and for the evaluation of decisions on protection systems in high-hazard industries. Up to this time, however, there has been no universally agreed measure for the utility of money, with many utility functions being in common use. In this paper, we shall derive a single family of utility functions, which have risk-aversion as the only free parameter. The fact that they return a utility of zero at their low, reference datum, either the utility of no money or of one unit of money, irrespective of the value of risk-aversion used, qualifies them to be regarded as absolute scales for the utility of money. Evidence of validation for the concept will be offered based on inferential measurements of risk-aversion, using diverse measurement data.

  18. Absolute stress measurements at the rangely anticline, Northwestern Colorado

    USGS Publications Warehouse

    de la Cruz, R. V.; Raleigh, C.B.

    1972-01-01

    Five different methods of measuring absolute state of stress in rocks in situ were used at sites near Rangely, Colorado, and the results compared. For near-surface measurements, overcoring of the borehole-deformation gage is the most convenient and rapid means of obtaining reliable values for the magnitude and direction of the state of stress in rocks in situ. The magnitudes and directions of the principal stresses are compared to the geologic features of the different areas of measurement. The in situ stresses are consistent in orientation with the stress direction inferred from the earthquake focal-plane solutions and existing joint patterns but inconsistent with stress directions likely to have produced the Rangely anticline. ?? 1972.

  19. Comparison of Two Algorithms for Analysis of Perfusion Computed Tomography Data for Evaluation of Cerebral Microcirculation in Chronic Subdural Hematoma.

    PubMed

    Trofimov, Alexey O; Kalentiev, George; Voennov, Oleg; Yuriev, Michail; Agarkova, Darya; Trofimova, Svetlana; Bragin, Denis E

    2016-01-01

    The aim of this work was comparison of two algorithms of perfusion computed tomography (PCT) data analysis for evaluation of cerebral microcirculation in the perifocal zone of chronic subdural hematoma (CSDH). Twenty patients with CSDH after polytrauma were included in the study. The same PCT data were assessed quantitatively in cortical brain region beneath the CSDH (zone 1), and in the corresponding contralateral brain hemisphere (zone 2) without and with the use of perfusion calculation mode excluding vascular pixel 'Remote Vessels' (RV); 1st and 2nd analysis method, respectively. Comparison with normal values for perfusion indices in the zone 1 in the 1st analysis method showed a significant (p < 0.01) increase in CBV and CBF, and no significant increase in MTT and TTP. Use of the RV mode (2nd analysis method) showed no statistically reliable change of perfusion parameters in the microcirculatory blood flow of the 2nd zone. Maintenance of microcirculatory blood flow perfusion reflects the preservation of cerebral blood flow autoregulation in patients with CSDH. PMID:27526170

  20. Residual heterogeneity of intra- and interregional pulmonary perfusion in short-term microgravity.

    PubMed

    Montmerle, Stéphanie; Sundblad, Patrik; Linnarsson, Dag

    2005-06-01

    We hypothesized that the perfusion heterogeneity in the human, upright lung is determined by nongravitational more than gravitational factors. Twelve and six subjects were studied during two series of parabolic flights. We used cardiogenic oscillations of O(2)/SF(6) as an indirect estimate of intraregional perfusion heterogeneity (series 1) and phase IV amplitude (P(4)) as a indirect estimate of interregional perfusion heterogeneity (series 2). A rebreathing-breath holding-expiration maneuver was performed. In flight, breath holding and expiration were performed either in microgravity (0 G) or in hypergravity. Controls were performed at normal gravity (1 G). In series 1, expiration was performed at 0 G. Cardiogenic oscillations of O(2)/SF(6) were 19% lower when breath holding was performed at 0 G than when breath holding was performed at 1 G [means (SD): 1.7 (0.3) and 2.3 (0.6)% units] (P = 0.044). When breath holding was performed at 1.8 G, values did not differ from 1-G control [2.6 (0.8)% units, P = 0.15], but they were 17% larger at 1.8 G than at 1 G. In series 2, expiration was performed at 1.7 G. P(4) changed with gravity (P < 0.001). When breath holding was performed at 0 G, P(4) values were 45 (46)% of control. When breath holding was performed at 1.7 G, P(4) values were 183 (101)% of control. We conclude that more than one-half of indexes of perfusion heterogeneity at 1 G are caused by nongravitational mechanisms. PMID:15718403

  1. Perfusion in free breast reconstruction flap zones assessed with positron emission tomography.

    PubMed

    Schrey, Aleksi; Kinnunen, Ilpo; Kalliokoski, Kari; Minn, Heikki; Grénman, Reidar; Vahlberg, Tero; Niemi, Tarja; Suominen, Erkki; Aitasalo, Kalle

    2010-09-01

    The aim of this pilot study was to determine the postoperative blood perfusion (BF(PET)) and perfusion heterogeneity (BF(PET) HG) in free microvascular breast reconstruction flap zones with positron emission tomography (PET). Regional BF(PET) and BF(PET) HG of the adipose tissue in medial, central, and lateral parts of 13 free flaps were assessed on the first postoperative morning with PET using oxygen-15-labeled water ([(15)O]H(2)O) in 12 patients undergoing breast reconstruction with a deep inferior epigastric perforator (DIEP) or a transverse rectus abdominis muscle (TRAM) flap. The mean BF(PET) values did not differ between DIEP and TRAM flaps (P = 0.791). The mean BF(PET) values were higher in zone III compared with zone I (P = 0.024). During follow-up, fat necrosis was identified in three patients in the medial part (zone II) of the flap. However, the adipose tissue BF(PET) assessed on the first postoperative day from all zones of the flap using PET with radiowater was normal. The BF(PET) HG was higher in the control side (i.e., in the healthy breast tissue) compared with the flap (P = 0.042). The BF(PET) HG was lower in zone III than in zone I (P = 0.03) and in zone II (P < 0.001). In this pilot study, PET was used for the first time for studying the adipose tissue perfusion in different zones in free flaps in a clinical setup, finding that the mean BF(PET) values did not differ between DIEP and TRAM flaps, and that zone II was sometimes not as well perfused as zone III supporting revisited zone division. PMID:20878725

  2. Lung Perfusion Measured Using Magnetic Resonance Imaging: New Tools for Physiological Insights Into the Pulmonary Circulation

    PubMed Central

    Hopkins, Susan R.; Prisk, G. Kim

    2012-01-01

    Since the lung receives the entire cardiac output, sophisticated imaging techniques are not required in order to measure total organ perfusion. However, for many years studying lung function has required physiologists to consider the lung as a single entity: in imaging terms as a single voxel. Since imaging, and in particular functional imaging, allows the acquisition of spatial information important for studying lung function, these techniques provide considerable promise and are of great interest for pulmonary physiologists. In particular, despite the challenges of low proton density and short T2* in the lung, noncontrast MRI techniques to measure pulmonary perfusion have several advantages including high reliability and the ability to make repeated measurements under a number of physiologic conditions. This brief review focuses on the application of a particular arterial spin labeling (ASL) technique, ASL-FAIRER (flow sensitive inversion recovery with an extra radiofrequency pulse), to answer physiologic questions related to pulmonary function in health and disease. The associated measurement of regional proton density to correct for gravitational-based lung deformation (the “Slinky” effect (Slinky is a registered trademark of PaufSlinky incorporated)) and issues related to absolute quantification are also discussed. PMID:21105135

  3. Observing absolute gravity change in the Fennoscandian postglacial rebound area

    NASA Astrophysics Data System (ADS)

    Mäkinen, J.; Engfeldt, A.; Gitlein, O.; Kaminskis, J.; Klopping, F.; Oja, T.; Paršeliunas, E.; Pettersen, B. R.; Strykowski, G.; Wilmes, H.

    2009-04-01

    Absolute gravity measurements in the Fennoscandian postglacial rebound area started already in 1976 when a team from Istituto di Metrología "G. Colonnetti" (Torino) measured six stations with the rise-and-fall gravimeter IMGC (Cannizzo et al., 1978). In 1980 two stations were measured by the team of the AN SSSR from Novosibirsk, using the gravimeter GABL (Arnautov et al., 1982). From the beginning the goal was to establish reference values for future remeasurement in order to detect gravity change due to the postglacial rebound. The maximum uplift rates are 1 cm/yr, which implies a surface gravity change of about -2 microgal/yr. In 1988, regular repeat measurements were began by the Finnish Geodetic Institute (FGI) with the JILAg-5. An important advance was the introduction of FG5 gravimeters into the work by BKG (Frankfurt a/M) and NOAA (Boulder, CO) in 1993. In 2003 annual large-scale campaigns with FG5 gravimeters started, coordinated by the Working Group for Geodynamics of the Nordic Geodetic Commission (NKG). This was prompted by the launch of the GRACE satellite gravity mission, which made it important to collect a comprehensive set of ground-truth values of gravity change during the lifetime of the satellite pair. The initial participation by gravimeter teams of Leibniz Universität Hannover, FGI and BKG has since expanded to include the University of Life Sciences (Ås, Norway) and Lantmäteriet (Gävle, Sweden). At present some 50 sites have repeated absolute measurements and most of them are co-located with continuous GPS. We give an overview of the sites, instrumentation and campaigns, and show examples of results achieved so far.

  4. Use of Absolute and Comparative Performance Feedback in Absolute and Comparative Judgments and Decisions

    ERIC Educational Resources Information Center

    Moore, Don A.; Klein, William M. P.

    2008-01-01

    Which matters more--beliefs about absolute ability or ability relative to others? This study set out to compare the effects of such beliefs on satisfaction with performance, self-evaluations, and bets on future performance. In Experiment 1, undergraduate participants were told they had answered 20% correct, 80% correct, or were not given their…

  5. Confidentiality: a modified value.

    PubMed Central

    Emson, H E

    1988-01-01

    In its original expression as a medical value confidentiality may have been absolute; this concept has become eroded by patient consent, legal actions and change in the climate of public opinion. In particular requirements arising out of legal statutes and common law judgements have greatly modified the confidentiality of the doctor-patient relationship in societies deriving their law from English origins. Despite this, confidentiality remains a value which the physician must strive to preserve. He cannot however do this without considering its effect upon possible innocent third parties. PMID:3392723

  6. What Value "Value Added"?

    ERIC Educational Resources Information Center

    Richards, Andrew

    2015-01-01

    Two quantitative measures of school performance are currently used, the average points score (APS) at Key Stage 2 and value-added (VA), which measures the rate of academic improvement between Key Stage 1 and 2. These figures are used by parents and the Office for Standards in Education to make judgements and comparisons. However, simple…

  7. Magnetic Resonance Perfusion Imaging in the Study of Language

    ERIC Educational Resources Information Center

    Hillis, Argye E.

    2007-01-01

    This paper provides a brief review of various uses of magnetic resonance perfusion imaging in the investigation of brain/language relationships. The reviewed studies illustrate how perfusion imaging can reveal areas of brain where dysfunction due to low blood flow is associated with specific language deficits, and where restoration of blood flow…

  8. Perfusion Electronic Record Documentation Using Epic Systems Software.

    PubMed

    Riley, Jeffrey B; Justison, George A

    2015-12-01

    The authors comment on Steffens and Gunser's article describing the University of Wisconsin adoption of the Epic anesthesia record to include perfusion information from the cardiopulmonary bypass patient experience. We highlight the current-day lessons and the valuable quality and safety principles the Wisconsin-Epic model anesthesia-perfusion record provides. PMID:26834289

  9. Absolute calibration of ultraviolet filter photometry

    NASA Technical Reports Server (NTRS)

    Bless, R. C.; Fairchild, T.; Code, A. D.

    1972-01-01

    The essential features of the calibration procedure can be divided into three parts. First, the shape of the bandpass of each photometer was determined by measuring the transmissions of the individual optical components and also by measuring the response of the photometer as a whole. Secondly, each photometer was placed in the essentially-collimated synchrotron radiation bundle maintained at a constant intensity level, and the output signal was determined from about 100 points on the objective. Finally, two or three points on the objective were illuminated by synchrotron radiation at several different intensity levels covering the dynamic range of the photometers. The output signals were placed on an absolute basis by the electron counting technique described earlier.

  10. MAGSAT: Vector magnetometer absolute sensor alignment determination

    NASA Technical Reports Server (NTRS)

    Acuna, M. H.

    1981-01-01

    A procedure is described for accurately determining the absolute alignment of the magnetic axes of a triaxial magnetometer sensor with respect to an external, fixed, reference coordinate system. The method does not require that the magnetic field vector orientation, as generated by a triaxial calibration coil system, be known to better than a few degrees from its true position, and minimizes the number of positions through which a sensor assembly must be rotated to obtain a solution. Computer simulations show that accuracies of better than 0.4 seconds of arc can be achieved under typical test conditions associated with existing magnetic test facilities. The basic approach is similar in nature to that presented by McPherron and Snare (1978) except that only three sensor positions are required and the system of equations to be solved is considerably simplified. Applications of the method to the case of the MAGSAT Vector Magnetometer are presented and the problems encountered discussed.

  11. Absolute geostrophic currents in global tropical oceans

    NASA Astrophysics Data System (ADS)

    Yang, Lina; Yuan, Dongliang

    2016-03-01

    A set of absolute geostrophic current (AGC) data for the period January 2004 to December 2012 are calculated using the P-vector method based on monthly gridded Argo profiles in the world tropical oceans. The AGCs agree well with altimeter geostrophic currents, Ocean Surface Current Analysis-Real time currents, and moored current-meter measurements at 10-m depth, based on which the classical Sverdrup circulation theory is evaluated. Calculations have shown that errors of wind stress calculation, AGC transport, and depth ranges of vertical integration cannot explain non-Sverdrup transport, which is mainly in the subtropical western ocean basins and equatorial currents near the Equator in each ocean basin (except the North Indian Ocean, where the circulation is dominated by monsoons). The identified non-Sverdrup transport is thereby robust and attributed to the joint effect of baroclinicity and relief of the bottom (JEBAR) and mesoscale eddy nonlinearity.

  12. Absolute Measurement of Electron Cloud Density

    SciTech Connect

    Covo, M K; Molvik, A W; Cohen, R H; Friedman, A; Seidl, P A; Logan, G; Bieniosek, F; Baca, D; Vay, J; Orlando, E; Vujic, J L

    2007-06-21

    Beam interaction with background gas and walls produces ubiquitous clouds of stray electrons that frequently limit the performance of particle accelerator and storage rings. Counterintuitively we obtained the electron cloud accumulation by measuring the expelled ions that are originated from the beam-background gas interaction, rather than by measuring electrons that reach the walls. The kinetic ion energy measured with a retarding field analyzer (RFA) maps the depressed beam space-charge potential and provides the dynamic electron cloud density. Clearing electrode current measurements give the static electron cloud background that complements and corroborates with the RFA measurements, providing an absolute measurement of electron cloud density during a 5 {micro}s duration beam pulse in a drift region of the magnetic transport section of the High-Current Experiment (HCX) at LBNL.

  13. Swarm's Absolute Scalar Magnetometer metrological performances

    NASA Astrophysics Data System (ADS)

    Leger, J.; Fratter, I.; Bertrand, F.; Jager, T.; Morales, S.

    2012-12-01

    The Absolute Scalar Magnetometer (ASM) has been developed for the ESA Earth Observation Swarm mission, planned for launch in November 2012. As its Overhauser magnetometers forerunners flown on Oersted and Champ satellites, it will deliver high resolution scalar measurements for the in-flight calibration of the Vector Field Magnetometer manufactured by the Danish Technical University. Latest results of the ground tests carried out to fully characterize all parameters that may affect its accuracy, both at instrument and satellite level, will be presented. In addition to its baseline function, the ASM can be operated either at a much higher sampling rate (burst mode at 250 Hz) or in a dual mode where it also delivers vector field measurements as a by-product. The calibration procedure and the relevant vector performances will be discussed.

  14. Absolute nonlocality via distributed computing without communication

    NASA Astrophysics Data System (ADS)

    Czekaj, Ł.; Pawłowski, M.; Vértesi, T.; Grudka, A.; Horodecki, M.; Horodecki, R.

    2015-09-01

    Understanding the role that quantum entanglement plays as a resource in various information processing tasks is one of the crucial goals of quantum information theory. Here we propose an alternative perspective for studying quantum entanglement: distributed computation of functions without communication between nodes. To formalize this approach, we propose identity games. Surprisingly, despite no signaling, we obtain that nonlocal quantum strategies beat classical ones in terms of winning probability for identity games originating from certain bipartite and multipartite functions. Moreover we show that, for a majority of functions, access to general nonsignaling resources boosts success probability two times in comparison to classical ones for a number of large enough outputs. Because there are no constraints on the inputs and no processing of the outputs in the identity games, they detect very strong types of correlations: absolute nonlocality.

  15. The pediatric template of brain perfusion

    PubMed Central

    Avants, Brian B; Duda, Jeffrey T; Kilroy, Emily; Krasileva, Kate; Jann, Kay; Kandel, Benjamin T; Tustison, Nicholas J; Yan, Lirong; Jog, Mayank; Smith, Robert; Wang, Yi; Dapretto, Mirella; Wang, Danny J J

    2015-01-01

    Magnetic resonance imaging (MRI) captures the dynamics of brain development with multiple modalities that quantify both structure and function. These measurements may yield valuable insights into the neural patterns that mark healthy maturation or that identify early risk for psychiatric disorder. The Pediatric Template of Brain Perfusion (PTBP) is a free and public neuroimaging resource that will help accelerate the understanding of childhood brain development as seen through the lens of multiple modality neuroimaging and in relation to cognitive and environmental factors. The PTBP uses cross-sectional and longitudinal MRI to quantify cortex, white matter, resting state functional connectivity and brain perfusion, as measured by Arterial Spin Labeling (ASL), in 120 children 7–18 years of age. We describe the PTBP and show, as a demonstration of validity, that global summary measurements capture the trajectories that demarcate critical turning points in brain maturation. This novel resource will allow a more detailed understanding of the network-level, structural and functional landmarks that are obtained during normal adolescent brain development. PMID:25977810

  16. Effects of increased heart work on glycolysis and adenine nucleotides in the perfused heart of normal and diabetic rats

    PubMed Central

    Opie, L. H.; Mansford, K. R. L.; Owen, Patricia

    1971-01-01

    1. In the isolated perfused rat heart, the contractile activity and the oxygen uptake were varied by altering the aortic perfusion pressure, or by the atrial perfusion technique (`working heart'). 2. The maximum increase in the contractile activity brought about an eightfold increase in the oxygen uptake. The rate of glycolytic flux rose, while tissue contents of hexose monophosphates, citrate, ATP and creatine phosphate decreased, and contents of ADP and AMP rose. 3. The changes in tissue contents of adenine nucleotides during increased heart work were time-dependent. The ATP content fell temporarily (30s and 2min) after the start of left-atrial perfusion; at 5 and 10min values were normal; and at 30 and 60min values were decreased. ADP and AMP values were increased in the first 15min, but were at control values 30 or 60min after the onset of increased heart work. 4. During increased heart work changes in the tissue contents of adenine nucleotide and of citrate appeared to play a role in altered regulation of glycolysis at the level of phosphofructokinase activity. 5. In recirculation experiments increased heart work for 30min was associated with increased entry of [14C]glucose (11.1mm) and glycogen into glycolysis and a comparable increase in formation of products of glycolysis (lactate, pyruvate and 14CO2). There was no major accumulation of intermediates. Glycogen was not a major fuel for respiration. 6. Increased glycolytic flux in Langendorff perfused and working hearts was obtained by the addition of insulin to the perfusion medium. The concomitant increases in the tissue values of hexose phosphates and of citrate contrasted with the decreased values of hexose monophosphates and of citrate during increased glycolytic flux obtained by increased heart work. 7. Decreased glycolytic flux in Langendorff perfused hearts was obtained by using acute alloxan-diabetic and chronic streptozotocin-diabetic rats; in the latter condition there were decreased tissue

  17. Hepatic perfusion abnormalities during CT angiography: Detection and interpretation

    SciTech Connect

    Freeny, P.C.; Marks, W.M.

    1986-06-01

    Twenty-seven perfusion abnormalities were detected in 17 of 50 patients who underwent computed tomographic angiography (CTA) of the liver. All but one of the perfusion abnormalities occurred in patients with primary or metastatic liver tumors. Perfusion abnormalities were lobar in nine cases, segmental in 11, and subsegmental in seven; 14 were hypoperfusion and 13 were hyperperfusion abnormalities. The causes for the abnormalities included nonperfusion of a replaced hepatic artery (n = 11), cirrhosis and nodular regeneration (n = 3), altered hepatic hemodynamics (e.g., siphoning, laminar flow) caused by tumor (n = 7), contrast media washout from a nonperfused vessel (n = 1), compression of adjacent hepatic parenchyma (n = 1), and unknown (n = 4). Differentiation of perfusion abnormalities from tumor usually can be made by comparing the morphology of the known tumor with the suspected perfusion abnormality, changes of each on delayed CTA scans, and review of initial angiograms and other imaging studies.

  18. Clinical experience with technetium-99m DTPA aerosol with perfusion scintigraphy in suspected pulmonary embolism

    SciTech Connect

    Selby, J.B.; Gardner, J.J.

    1987-01-01

    To evaluate the clinical value of radioaerosol imaging, 156 patients with suspected pulmonary embolism (PE) were studied. In 25 patients, a preperfusion xenon-133 (Xe-133) study was compared with a postperfusion study using Tc-99m DTPA aerosol. It was found that they were of equal value most of the time (56%), but that the aerosol study was more often helpful. Because of this, and the technical ease of using six standard views with radioaerosol, the series was completed using perfusion scintigraphy followed by radioaerosol images. In 19 patients the perfusion scintigraphy with Tc-99 macroaggregated albumin (Tc-99m MAA) was normal or nearly normal and no aerosol study was required. Tc-99m DTPA aerosol images were satisfactory when the count rate was at least twice and preferably three times that of the previous perfusion study. There were 17 studies (11%) classified as intermediate. There were 26 patients classified as high probability for PE, and angiographic or autopsy correlation was available in 14. All of the 14 proved to have PE. In the 113 patients classified as low probability, there were ten with angiographic or autopsy correlation. In the ten, there was one patient with a small pulmonary embolus found at autopsy. Clinical follow-up for over two months confirmed the absence of PE in the remainder of this group. Aerosol studies have proven technically easier to perform and a satisfactory substitute for xenon imaging in suspected PE.

  19. Vertebral artery hypoplasia, posterior circulation infarction and relative hypoperfusion detected by perfusion magnetic resonance imaging semiquantitatively.

    PubMed

    Zhang, Dao Pei; Ma, Qian Kun; Zhang, Jie Wen; Zhang, Shu Ling; Lu, Gui Feng; Yin, Suo

    2016-09-15

    Vertebral artery hypoplasia (VAH) has been considered a risk factor of posterior circulation infarction (PCI), especially in the territory of the posterior inferior cerebellar artery (PICA). But whether VAH is an independent risk factor for PCI remains uncertain and how VAH participates in the evolvement of PCI is still not clear either. Therefore, this study aims to examine whether VAH is an independent risk factor for PCI and evaluate the effect of VAH on the cerebral perfusion in the territory of the PICA detected by perfusion magnetic resonance imaging (MRI) semiquantitatively. Both univariate and multivariate analyses showed that VAH, hypertension and smoking were more frequent in patients with PCI than in patients without PCI. Perfusion MRI analysis found that there were remarkable differences in the frequency of the relative cerebral blood flow (rCBF) value ≤0.85 and the relative time to peak (rTTP) values between VAH patients without PCI and non-VAH patients without PCI. Our results indicated that VAH may be an independent risk factor for PCI, especially in the presence of hypertension and smoking and that a relative hypoperfusion associates with VAH that may contribute to the evolvement of the infarction in the PICA territory. PMID:27538599

  20. Contrast enhanced ultrasound with quantitative perfusion analysis for objective characterization of pancreatic ductal adenocarcinoma: A feasibility study.

    PubMed

    D'Onofrio, Mirko; Canestrini, Stefano; Crosara, Stefano; De Robertis, Riccardo; Pozzi Mucelli, Roberto

    2014-03-28

    The aim of this study was to determine whether contrast enhanced ultrasound (CEUS) quantitative perfusion analysis allows an objective characterization of ductal adenocarcinoma (ADK) of the pancreas. Patients with pancreatic ADK underwent CEUS. All examinations were performed on an Acuson S2000 system (Siemens, Erlangen, Germany) after the iv administration of 2.4 mL contrast agent (SonoVue(®), Bracco, Milan, Italy). All lesions were pathologically proved. An operator manually drew different regions of interest within the tumor and the adjacent parenchyma to allow the quantitative perfusion analysis. The mean values of peak of enhancement, time to peak and ascending curve were calculated and compared using the Student's t test. The quantitative perfusion analysis was possible in all lesions. The mean values of the peak of enhancement, time to peak and ascending curve were 17.19%, 7.97 s and 159.52% s within the tumor and 33.57%, 8.89 s and 355.29% s within the adjacent parenchyma. The peak of enhancement and the ascending curve values were significantly different within the tumor and the adjacent parenchyma. Thus, CEUS allows the quantitative perfusion analysis of pancreatic ductal adenocarcinoma. PMID:24765238

  1. Comparison of Perfusion- and Diffusion-weighted Imaging Parameters in Brain Tumor Studies Processed Using Different Software Platforms

    PubMed Central

    Milchenko, Mikhail V.; Rajderkar, Dhanashree; LaMontagne, Pamela; Massoumzadeh, Parinaz; Bogdasarian, Ronald; Schweitzer, Gordon; Benzinger, Tammie; Marcus, Dan; Shimony, Joshua S.; Fouke, Sarah Jost

    2015-01-01

    Rationale and Objectives To compare quantitative imaging parameter measures from diffusion- and perfusion-weighted imaging magnetic resonance imaging (MRI) sequences in subjects with brain tumors that have been processed with different software platforms. Materials and Methods Scans from 20 subjects with primary brain tumors were selected from the Comprehensive Neuro-oncology Data Repository at Washington University School of Medicine (WUSM) and the Swedish Neuroscience Institute. MR images were coregistered, and each subject's data set was processed by three software packages: 1) vendor-specific scanner software, 2) research software developed at WUSM, and 3) a commercially available, Food and Drug Administration–approved, processing platform (Nordic Ice). Regions of interest (ROIs) were chosen within the brain tumor and normal nontumor tissue. The results obtained using these methods were compared. Results For diffusion parameters, including mean diffusivity and fractional anisotropy, concordance was high when comparing different processing methods. For perfusion-imaging parameters, a significant variance in cerebral blood volume, cerebral blood flow, and mean transit time (MTT) values was seen when comparing the same raw data processed using different software platforms. Correlation was better with larger ROIs (radii ≥ 5 mm). Greatest variance was observed in MTT. Conclusions Diffusion parameter values were consistent across different software processing platforms. Perfusion parameter values were more variable and were influenced by the software used. Variation in the MTT was especially large suggesting that MTT estimation may be unreliable in tumor tissues using current MRI perfusion methods. PMID:25088833

  2. Contrast enhanced ultrasound with quantitative perfusion analysis for objective characterization of pancreatic ductal adenocarcinoma: A feasibility study

    PubMed Central

    D’Onofrio, Mirko; Canestrini, Stefano; Crosara, Stefano; Robertis, Riccardo De; Mucelli, Roberto Pozzi

    2014-01-01

    The aim of this study was to determine whether contrast enhanced ultrasound (CEUS) quantitative perfusion analysis allows an objective characterization of ductal adenocarcinoma (ADK) of the pancreas. Patients with pancreatic ADK underwent CEUS. All examinations were performed on an Acuson S2000 system (Siemens, Erlangen, Germany) after the iv administration of 2.4 mL contrast agent (SonoVue®, Bracco, Milan, Italy). All lesions were pathologically proved. An operator manually drew different regions of interest within the tumor and the adjacent parenchyma to allow the quantitative perfusion analysis. The mean values of peak of enhancement, time to peak and ascending curve were calculated and compared using the Student’s t test. The quantitative perfusion analysis was possible in all lesions. The mean values of the peak of enhancement, time to peak and ascending curve were 17.19%, 7.97 s and 159.52% s within the tumor and 33.57%, 8.89 s and 355.29% s within the adjacent parenchyma. The peak of enhancement and the ascending curve values were significantly different within the tumor and the adjacent parenchyma. Thus, CEUS allows the quantitative perfusion analysis of pancreatic ductal adenocarcinoma. PMID:24765238

  3. Quantitative Perfusion and Permeability Biomarkers in Brain Cancer from Tomographic CT and MR Images

    PubMed Central

    Eilaghi, Armin; Yeung, Timothy; d’Esterre, Christopher; Bauman, Glenn; Yartsev, Slav; Easaw, Jay; Fainardi, Enrico; Lee, Ting-Yim; Frayne, Richard

    2016-01-01

    Dynamic contrast-enhanced perfusion and permeability imaging, using computed tomography and magnetic resonance systems, are important techniques for assessing the vascular supply and hemodynamics of healthy brain parenchyma and tumors. These techniques can measure blood flow, blood volume, and blood–brain barrier permeability surface area product and, thus, may provide information complementary to clinical and pathological assessments. These have been used as biomarkers to enhance the treatment planning process, to optimize treatment decision-making, and to enable monitoring of the treatment noninvasively. In this review, the principles of magnetic resonance and computed tomography dynamic contrast-enhanced perfusion and permeability imaging are described (with an emphasis on their commonalities), and the potential values of these techniques for differentiating high-grade gliomas from other brain lesions, distinguishing true progression from posttreatment effects, and predicting survival after radiotherapy, chemotherapy, and antiangiogenic treatments are presented. PMID:27398030

  4. Nitrogen metabolism in the isolated perfused rat liver. Nitrogen balance, redox state and rates of proteolysis.

    PubMed

    Parrilla, R; Goodman, M N

    1974-03-01

    Nitrogen balances were measured in isolated perfused rat livers in the presence and absence of nitrogen donors. In all instances the balance apparently was incomplete. The expression [alanine][alpha-oxoglutarate]/[pyruvate][glutamate] remained fairly constant under the metabolic conditions studied, indicating that it may be at near-equilibrium. The source of the extra nitrogen seems to be derived from increased hepatic proteolysis. The addition of a nitrogen donor to the perfusate arrested proteolysis, as did the addition of pyruvate. The free mitochondrial [NAD(+)]/[NADH] ratio, calculated from the glutamate dehydrogenase and beta-hydroxybutyrate dehydrogenase reactants, showed similar values and exhibited parallel changes under most metabolic situations studied. These results suggest that, under the reported experimental conditions, both dehydrogenases share a common mitochondrial NAD pool. Glutamate dehydrogenase plays an important role in hepatic nitrogen metabolism in vivo. PMID:4372991

  5. Using absolute gravimeter data to determine vertical gravity gradients

    USGS Publications Warehouse

    Robertson, D.S.

    2001-01-01

    The position versus time data from a free-fall absolute gravimeter can be used to estimate the vertical gravity gradient in addition to the gravity value itself. Hipkin has reported success in estimating the vertical gradient value using a data set of unusually good quality. This paper explores techniques that may be applicable to a broader class of data that may be contaminated with "system response" errors of larger magnitude than were evident in the data used by Hipkin. This system response function is usually modelled as a sum of exponentially decaying sinusoidal components. The technique employed here involves combining the x0, v0 and g parameters from all the drops made during a site occupation into a single least-squares solution, and including the value of the vertical gradient and the coefficients of system response function in the same solution. The resulting non-linear equations must be solved iteratively and convergence presents some difficulties. Sparse matrix techniques are used to make the least-squares problem computationally tractable.

  6. Nifedipine and thallium-201 myocardial perfusion in progressive systemic sclerosis

    SciTech Connect

    Kahan, A.; Devaux, J.Y.; Amor, B.; Menkes, C.J.; Weber, S.; Nitenberg, A.; Venot, A.; Guerin, F.; Degeorges, M.; Roucayrol, J.C.

    1986-05-29

    Heart disease in patients with progressive systemic sclerosis may be due in part to myocardial ischemia caused by a disturbance of the coronary microcirculation. To determine whether abnormalities of myocardial perfusion in this disorder are potentially reversible, we evaluated the effect of the coronary vasodilator nifedipine on myocardial perfusion assessed by thallium-201 scanning in 20 patients. Thallium-201 single-photon-emission computerized tomography was performed under control conditions and 90 minutes after 20 mg of oral nifedipine. The mean (+/- SD) number of left ventricular segments with perfusion defects decreased from 5.3 +/- 2.0 to 3.3 +/- 2.2 after nifedipine (P = 0.0003). Perfusion abnormalities were quantified by a perfusion score (0 to 2.0) assigned to each left ventricular segment and by a global perfusion score (0 to 18) for the entire left ventricle. The mean perfusion score in segments with resting defects increased from 0.97 +/- 0.24 to 1.26 +/- 0.44 after nifedipine (P less than 0.00001). The mean global perfusion score increased from 11.2 +/- 1.7 to 12.8 +/- 2.4 after nifedipine (P = 0.003). The global perfusion score increased by at least 2.0 in 10 patients and decreased by at least 2.0 in only 1. These observations reveal short-term improvement in thallium-201 myocardial perfusion with nifedipine in patients with progressive systemic sclerosis. The results are consistent with a potentially reversible abnormality of coronary vasomotion in this disorder, but the long-term therapeutic effects of nifedipine remain to be determined.

  7. Performance assessment of a new dynamic scan mode for perfusion computed tomography using a biological phantom

    NASA Astrophysics Data System (ADS)

    Haberland, U.; Klotz, E.,; Abolmaali, N.

    2010-04-01

    Perfusion computed tomography is increasingly being used for stroke and tumor assessment. Using continuous periodic table movement the spatial coverage can be increased beyond the detector width with a new adaptive spiral scanning technique (A4DS). The purpose of this study was to compare perfusion values acquired with the A4DS technique with results from standard dynamic scans at different temporal sampling rates. A biological perfusion phantom (preserved porcine kidney) was scanned with both techniques. In standard mode three scans were performed at adjacent overlapping positions (detector width 38.4 mm) covering the whole phantom. Data were reconstructed with temporal resolutions of 0.5, 1 and 1.5 s. The A4DS scan was performed with a cycle time of 1.5 s and scan ranges of 100 and 148 mm respectively. The phantom was not repositioned between scans in order to assure that identical image slices showed identical phantom slices. Tissue flow was calculated with a deconvolution type algorithm. Regions of interest were drawn in strongly and moderately enhancing areas and around the whole cortex in three slices in the upper, central and lower portion of the phantom. In the flow range of 40 to 100 ml/100ml/min values did not differ by more than 5 ml/100ml/min between any of the scan protocols used. The correlation between the continuous table movement modes and the 0.5 s standard mode was excellent (r2>0.98) indicating that the new mode is well suited for perfusion measurements and allows increasing the coverage by almost a factor of four.

  8. New identification method for Hammerstein models based on approximate least absolute deviation

    NASA Astrophysics Data System (ADS)

    Xu, Bao-Chang; Zhang, Ying-Dan

    2016-07-01

    Disorder and peak noises or large disturbances can deteriorate the identification effects of Hammerstein non-linear models when using the least-square (LS) method. The least absolute deviation technique can be used to resolve this problem; however, its absolute value cannot meet the need of differentiability required by most algorithms. To improve robustness and resolve the non-differentiable problem, an approximate least absolute deviation (ALAD) objective function is established by introducing a deterministic function that exhibits the characteristics of absolute value under certain situations. A new identification method for Hammerstein models based on ALAD is thus developed in this paper. The basic idea of this method is to apply the stochastic approximation theory in the process of deriving the recursive equations. After identifying the parameter matrix of the Hammerstein model via the new algorithm, the product terms in the matrix are separated by calculating the average values. Finally, algorithm convergence is proven by applying the ordinary differential equation method. The proposed algorithm has a better robustness as compared to other LS methods, particularly when abnormal points exist in the measured data. Furthermore, the proposed algorithm is easier to apply and converges faster. The simulation results demonstrate the efficacy of the proposed algorithm.

  9. Convective-to-absolute instability transition in a viscoelastic capillary jet subject to unrelaxed axial elastic tension.

    PubMed

    Mohamed, A Said; Herrada, M A; Gañán-Calvo, A M; Montanero, J M

    2015-08-01

    The convective-to-absolute instability transition in an Oldroyd-B capillary jet subject to unrelaxed axial stress is examined theoretically. There is a critical Weber number below which the jet is absolutely unstable under axisymmetric perturbations. We analyze the dependence of this critical parameter with respect to the Reynolds and Deborah numbers, as well as the unrelaxed axial stress. For small Deborah numbers, the unrelaxed stress destabilizes the viscoelastic jet, increasing the critical Weber number for which the convective-to-absolute instability transition takes place. If the Deborah number takes higher values, then the transitional Weber number decreases as the unrelaxed stress increases until two solution branches cross each other. The dominant branch for large axial stress leads to a threshold of this quantity above which the viscoelastic jet becomes absolutely unstable independently of the Weber number. The threshold depends on neither the Reynolds nor the Deborah number for sufficiently large values of these parameters. PMID:26382502

  10. Convective-to-absolute instability transition in a viscoelastic capillary jet subject to unrelaxed axial elastic tension

    NASA Astrophysics Data System (ADS)

    Mohamed, A. Said; Herrada, M. A.; Gañán-Calvo, A. M.; Montanero, J. M.

    2015-08-01

    The convective-to-absolute instability transition in an Oldroyd-B capillary jet subject to unrelaxed axial stress is examined theoretically. There is a critical Weber number below which the jet is absolutely unstable under axisymmetric perturbations. We analyze the dependence of this critical parameter with respect to the Reynolds and Deborah numbers, as well as the unrelaxed axial stress. For small Deborah numbers, the unrelaxed stress destabilizes the viscoelastic jet, increasing the critical Weber number for which the convective-to-absolute instability transition takes place. If the Deborah number takes higher values, then the transitional Weber number decreases as the unrelaxed stress increases until two solution branches cross each other. The dominant branch for large axial stress leads to a threshold of this quantity above which the viscoelastic jet becomes absolutely unstable independently of the Weber number. The threshold depends on neither the Reynolds nor the Deborah number for sufficiently large values of these parameters.

  11. Measurement of absolute optical thickness of mask glass by wavelength-tuning Fourier analysis.

    PubMed

    Kim, Yangjin; Hbino, Kenichi; Sugita, Naohiko; Mitsuishi, Mamoru

    2015-07-01

    Optical thickness is a fundamental characteristic of an optical component. A measurement method combining discrete Fourier-transform (DFT) analysis and a phase-shifting technique gives an appropriate value for the absolute optical thickness of a transparent plate. However, there is a systematic error caused by the nonlinearity of the phase-shifting technique. In this research the absolute optical-thickness distribution of mask blank glass was measured using DFT and wavelength-tuning Fizeau interferometry without using sensitive phase-shifting techniques. The error occurring during the DFT analysis was compensated for by using the unwrapping correlation. The experimental results indicated that the absolute optical thickness of mask glass was measured with an accuracy of 5 nm. PMID:26125394

  12. Absolute phase retrieval for defocused fringe projection three-dimensional measurement

    NASA Astrophysics Data System (ADS)

    Zheng, Dongliang; Da, Feipeng

    2014-02-01

    Defocused fringe projection three-dimensional technique based on pulse-width modulation (PWM) can generate high-quality sinusoidal fringe patterns. It only uses slightly defocused binary structured patterns which can eliminate the gamma problem (i.e. nonlinear response), and the phase error can be significantly reduced. However, when the projector is defocused, it is difficult to retrieve the absolute phase from the wrapped phase. A recently proposed phase coding method is efficient for absolute phase retrieval, but the gamma problem leads this method not so reliable. In this paper, we use the PWM technique to generate fringe patterns for the phase coding method. The gamma problem of the projector can be eliminated, and correct absolute phase can be retrieved. The proposed method only uses two grayscale values (0's and 255's), which can be used for real-time 3D shape measurement. Both simulation and experiment demonstrate the performance of the proposed method.

  13. Sounding rocket measurement of the absolute solar EUV flux utilizing a silicon photodiode

    NASA Technical Reports Server (NTRS)

    Ogawa, H. S.; Mcmullin, D.; Judge, D. L.; Canfield, L. R.

    1990-01-01

    A newly developed stable and high quantum efficiency silicon photodiode was used to obtain an accurate measurement of the integrated absolute magnitude of the solar extreme UV photon flux in the spectral region between 50 and 800 A. The adjusted daily 10.7-cm solar radio flux and sunspot number were 168.4 and 121, respectively. The unattenuated absolute value of the solar EUV flux at 1 AU in the specified wavelength region was 6.81 x 10 to the 10th photons/sq cm per s. Based on a nominal probable error of 7 percent for National Institute of Standards and Technology detector efficiency measurements in the 50- to 500-A region (5 percent on longer wavelength measurements between 500 and 1216 A), and based on experimental errors associated with the present rocket instrumentation and analysis, a conservative total error estimate of about 14 percent is assigned to the absolute integral solar flux obtained.

  14. STANDARDIZING TYPE Ia SUPERNOVA ABSOLUTE MAGNITUDES USING GAUSSIAN PROCESS DATA REGRESSION

    SciTech Connect

    Kim, A. G.; Aldering, G.; Aragon, C.; Bailey, S.; Childress, M.; Fakhouri, H. K.; Nordin, J.; Thomas, R. C.; Antilogus, P.; Bongard, S.; Canto, A.; Cellier-Holzem, F.; Guy, J.; Baltay, C.; Buton, C.; Kerschhaggl, M.; Kowalski, M.; Chotard, N.; Copin, Y.; Gangler, E.; and others

    2013-04-01

    We present a novel class of models for Type Ia supernova time-evolving spectral energy distributions (SEDs) and absolute magnitudes: they are each modeled as stochastic functions described by Gaussian processes. The values of the SED and absolute magnitudes are defined through well-defined regression prescriptions, so that data directly inform the models. As a proof of concept, we implement a model for synthetic photometry built from the spectrophotometric time series from the Nearby Supernova Factory. Absolute magnitudes at peak B brightness are calibrated to 0.13 mag in the g band and to as low as 0.09 mag in the z = 0.25 blueshifted i band, where the dispersion includes contributions from measurement uncertainties and peculiar velocities. The methodology can be applied to spectrophotometric time series of supernovae that span a range of redshifts to simultaneously standardize supernovae together with fitting cosmological parameters.

  15. Regional Myocardial Perfusion Rates in Patients with Coronary Artery Disease

    PubMed Central

    Cannon, Paul J.; Dell, Ralph B.; Dwyer, Edward M.

    1972-01-01

    Regional myocardial perfusion rates were estimated from the myocardial washout of 133Xenon in 24 patients with heart disease whose coronary arteriograms were abnormal and 17 similar subjects whose coronary arteriograms were judged to be normal. Disappearance rates of 133Xe from multiple areas of the heart were monitored externally with a multiple-crystal scintillation camera after the isotope had been injected into a coronary artery and local myocardial perfusion rates were calculated by the Kety formula. The mean myocardial perfusion rates in the left ventricle exceeded those in the right ventricle or atrial regions in subjects without demonstrable coronary artery disease. In this group there was a significant lack of homogeneity of local perfusion rates in left ventricular myocardium; the mean coefficient of variation of left ventricular local perfusion rates was 15.8%. In the patients with radiographically demonstrable coronary artery disease, a variety of myocardial perfusion patterns were observed. Local capillary blood flow rates were depressed throughout the myocardium of patients with diffuse coronary disease but were subnormal only in discrete myocardial regions of others with localized occlusive disease. Local myocardial perfusion rates were similar to those found in the group with normal coronary arteriograms in patients with slight degrees of coronary disease and in those areas of myocardium distal to marked coronary constrictions or occlusions which were well supplied by collateral vessels. In subjects with right coronary disease, the mean right ventricular perfusion rates were significantly subnormal; in seven subjects of this group perfusion of the inferior left ventricle by a dominant right coronary artery was absent or depressed. The average mean left ventricular perfusion rate of 12 subjects with significant disease of two or more branches of the left coronary artery was significantly lower than that of the group with normal left coronary

  16. Monitoring Groundwater Variations Using a Portable Absolute Gravimeter

    NASA Astrophysics Data System (ADS)

    Fukuda, Yoichi; Nishijima, Jun; Hasegawa, Takashi; Sofyan, Yayan; Taniguchi, Makoto; Abidin, Hasanuddin Z.; Delinom, Robert M.

    2010-05-01

    In urbanized areas, one of the urgent problems is to monitor the groundwater variations especially connected with land subsidence. Although the groundwater variations are usually measured by water level meters, gravity measurements can provide us additional information about the water mass movements which should be beneficial for the analyses of groundwater flow and the managements of water resources as well. Therefore, in order to establish a new technique to monitor the groundwater variations by means of the gravity measurements, we investigated the applicability of a portable type absolute gravimeter (Micro-G LaCoste Inc. A10-017). We will report the results of some test measurements in Japan, and the outline of the surveys in Jakarta, Indonesia. As for the absolute gravity measurements, FG-5 of MGL would be more popular. FG-5 is a high precision absolute gravimeter with a 2ugal-accuracy for laboratory use, while the nominal accuracy of A-10 is 10ugal (measurement precision: ±5ugal). In spite of the disadvantage, A-10 is well suited for the field surveys because it is much smaller than FG-5 and can be operated with 12VDC power. The repeated measurements using A10-017 in Kyushu University show good correlations between the measured gravity values and the groundwater levels in nearby observation wells. In a geothermal plant of Takigami, we also observed the gravity changes associated with the cycle of the geothermal fluid. All these test measurements have proved that the gravimeter can achieve a 10ugal (10nm/s2) or better accuracy in the field surveys. In Jakarta, Indonesia, excess groundwater pumping is going on and it causes land subsidence. To reveal the associated gravity changes, we conducted the first gravity survey in August 2008 and the second survey in July 2009. Mainly due to the instrumental troubles during the 2008 surveys, we have not obtained enough reliable data yet. Nevertheless the result obtained so far suggested the gravity increases in the

  17. Antiausterity activity of arctigenin enantiomers: importance of (2R,3R)-absolute configuration.

    PubMed

    Awale, Suresh; Kato, Mamoru; Dibwe, Dya Fita; Li, Feng; Miyoshi, Chika; Esumi, Hiroyasu; Kadota, Shigetoshi; Tezuka, Yasuhiro

    2014-01-01

    From a MeOH extract of powdered roots of Wikstroemia indica, six dibenzyl-gamma-butyrolactone-type lignans with (2S,3S)-absolute configuration [(+)-arctigenin (1), (+)-matairesinol (2), (+)-trachelogenin (3), (+)-nortrachelogenin (4), (+)-hinokinin (5), and (+)-kusunokinin (6)] were isolated, whereas three dibenzyl-gamma-butyrolactone-type lignans with (2R,3R)-absolute configuration [(-)-arctigenin (1*), (-)-matairesinol (2*), (-)-trachelogenin (3*)] were isolated from Trachelospermum asiaticum. The in vitro preferential cytotoxic activity of the nine compounds was evaluated against human pancreatic PANC-1 cancer cells in nutrient-deprived medium (NDM), but none of the six lignans (1-6) with (2S,3S)-absolute configuration showed preferential cytotoxicity. On the other hand, three lignans (1*-3*) with (2R,3R)-absolute configuration exhibited preferential cytotoxicity in a concentration-dependent manner with PC50 values of 0.54, 6.82, and 5.85 microM, respectively. Furthermore, the effect of (-)- and (+)-arctigenin was evaluated against the activation of Akt, which is a key process in the tolerance to nutrition starvation. Interestingly, only (-)-arctigenin (1*) strongly suppressed the activation of Akt. These results indicate that the (2R,3R)-absolute configuration of (-)-enantiomers should be required for the preferential cytotoxicity through the inhibition of Akt activation. PMID:24660468

  18. Absolute instabilities in a high-order-mode gyrotron traveling-wave amplifier.

    PubMed

    Tsai, W C; Chang, T H; Chen, N C; Chu, K R; Song, H H; Luhmann, N C

    2004-11-01

    The absolute instability is a subject of considerable physics interest as well as a major source of self-oscillations in the gyrotron traveling-wave amplifier (gyro-TWT). We present a theoretical study of the absolute instabilities in a TE01 mode, fundamental cyclotron harmonic gyro-TWT with distributed wall losses. In this high-order-mode circuit, absolute instabilities arise in a variety of ways, including overdrive of the operating mode, fundamental cyclotron harmonic interactions with lower-order modes, and second cyclotron harmonic interaction with a higher-order mode. The distributed losses, on the other hand, provide an effective means for their stabilization. The combined configuration thus allows a rich display of absolute instability behavior together with the demonstration of its control. We begin with a study of the field profiles of absolute instabilities, which exhibit a range of characteristics depending in large measure upon the sign and magnitude of the synchronous value of the propagation constant. These profiles in turn explain the sensitivity of oscillation thresholds to the beam and circuit parameters. A general recipe for oscillation stabilization has resulted from these studies and its significance to the current TE01 -mode, 94-GHz gyro-TWT experiment at UC Davis is discussed. PMID:15600760

  19. Utilizing a reference material for assessing absolute tumor mechanical properties in modality independent elastography

    NASA Astrophysics Data System (ADS)

    Kim, Dong Kyu; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    There is currently no reliable method for early characterization of breast cancer response to neoadjuvant chemotherapy (NAC) [1,2]. Given that disruption of normal structural architecture occurs in cancer-bearing tissue, we hypothesize that further structural changes occur in response to NAC. Consequently, we are investigating the use of modalityindependent elastography (MIE) [3-8] as a method for monitoring mechanical integrity to predict long term outcomes in NAC. Recently, we have utilized a Demons non-rigid image registration method that allows 3D elasticity reconstruction in abnormal tissue geometries, making it particularly amenable to the evaluation of breast cancer mechanical properties. While past work has reflected relative elasticity contrast ratios [3], this study improves upon that work by utilizing a known stiffness reference material within the reconstruction framework such that a stiffness map becomes an absolute measure. To test, a polyvinyl alcohol (PVA) cryogel phantom and a silicone rubber mock mouse tumor phantom were constructed with varying mechanical stiffness. Results showed that an absolute measure of stiffness could be obtained based on a reference value. This reference technique demonstrates the ability to generate accurate measurements of absolute stiffness to characterize response to NAC. These results support that `referenced MIE' has the potential to reliably differentiate absolute tumor stiffness with significant contrast from that of surrounding tissue. The use of referenced MIE to obtain absolute quantification of biomarkers is also translatable across length scales such that the characterization method is mechanics-consistent at the small animal and human application.

  20. The ability of intra-operative perfusion mapping with laser-assisted indocyanine green angiography to predict mastectomy flap necrosis in breast reconstruction: a prospective trial.

    PubMed

    Munabi, Naikhoba C O; Olorunnipa, Olushola B; Goltsman, David; Rohde, Christine H; Ascherman, Jeffrey A

    2014-04-01

    Mastectomy skin flap ischaemia leading to necrosis is a common occurrence. Laser-assisted indocyanine green (ICG) angiography can assist to locate these poorly perfused areas intra-operatively. Our study aims to identify specific perfusion values produced by ICG angiography that accurately predict mastectomy flap necrosis. A total of 42 patients undergoing autologous or implant-based breast reconstruction had mastectomy flaps imaged using laser-assisted ICG angiography at the completion of reconstruction. Intra-operative perfusion values were correlated with postoperative skin flap outcomes. Risk factors for abnormal perfusion were recorded and analysed. A total of 62 breast reconstructions were imaged, including 48 tissue expander reconstructions, six transverse rectus abdominis myocutaneous (TRAM) flaps, six deep inferior epigastric perforator (DIEP) flaps and two direct-to-implant reconstructions. Eight cases (13%) of full-thickness skin necrosis were identified postoperatively. A SPY Elite(®) value of ≤ 7 accurately predicted the development of flap necrosis at 88% sensitivity and 83% specificity. False-positive cases (those with perfusion values ≤ 7 which did not develop necrosis) were more likely to have a smoking history and/or to have had an epinephrine-containing tumescent solution used during mastectomy. Excluding patients with smoking or epinephrine use, a SPY value of ≤ 7 predicted flap necrosis with a sensitivity of 83% and specificity of 97%. Thus, these data suggest that laser-assisted ICG angiography predicts postoperative outcomes with high accuracy. In our series, a SPY value of ≤ 7 correlated well with mastectomy flap necrosis. Furthermore, smoking and intra-operative injections containing epinephrine should be considered when evaluating low perfusion values as they can lead to false-positive test results. PMID:24507962

  1. Measuring perfusion with light (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Jansen, Sanne M. A.; de Bruin, Daniel M.; Faber, Dirk J.; van Leeuwen, Ton G.

    2016-03-01

    There is no gold standard test for perfusion evaluation in surgery. Optical Imaging techniques are able to image tissue at high resolution and in real-time. Laser Speckle Contrast Imaging, Optical Coherence Tomography, Sidestream Darkfield and Incident Darkfield all use the interaction of light with tissue to create an image. To test their feasibility and explore validity in a controlled setting, we created a phantom with the optical properties of tissue and microvascular channels of 30-400 micrometer. With a Hamilton Syringe Pump we mimicked blood flow velocities of 0-20 mm/sec. Images of all different modalities at different blood flow velocities were compared in terms of imaging depth, resoluation and hemodynamic parameters.

  2. Adenosine thallium 201 myocardial perfusion scintigraphy

    SciTech Connect

    Verani, M.S. )

    1991-07-01

    Pharmacologic coronary vasodilation as an adjunct to myocardial perfusion imaging has become increasingly important in the evaluation of patients with coronary artery disease, in view of the large number of patients who cannot perform an adequate exercise test or in whom contraindications render exercise inappropriate. Adenosine is a very potent coronary vasodilator and when combined with thallium 201 scintigraphy produces images of high quality, with the added advantages of a very short half-life (less than 10 seconds) and the ability to adjust the dose during the infusion, which may enhance safety and curtail the duration of side effects. The reported sensitivity and specificity of adenosine thallium 201 scintigraphy for the detection of coronary artery disease are high and at least comparable with imaging after exercise or dipyridamole administration. 23 refs.

  3. Hydrogels for Engineering of Perfusable Vascular Networks

    PubMed Central

    Liu, Juan; Zheng, Huaiyuan; Poh, Patrina S. P.; Machens, Hans-Günther; Schilling, Arndt F.

    2015-01-01

    Hydrogels are commonly used biomaterials for tissue engineering. With their high-water content, good biocompatibility and biodegradability they resemble the natural extracellular environment and have been widely used as scaffolds for 3D cell culture and studies of cell biology. The possible size of such hydrogel constructs with embedded cells is limited by the cellular demand for oxygen and nutrients. For the fabrication of large and complex tissue constructs, vascular structures become necessary within the hydrogels to supply the encapsulated cells. In this review, we discuss the types of hydrogels that are currently used for the fabrication of constructs with embedded vascular networks, the key properties of hydrogels needed for this purpose and current techniques to engineer perfusable vascular structures into these hydrogels. We then discuss directions for future research aimed at engineering of vascularized tissue for implantation. PMID:26184185

  4. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    SciTech Connect

    Siva, Shankar; Hardcastle, Nicholas; Kron, Tomas; Bressel, Mathias; Callahan, Jason; MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki; Hicks, Rodney J.; Steinfort, Daniel; Ball, David L.; Hofman, Michael S.

    2015-10-01

    Purpose: To investigate {sup 68}Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r{sup 2}=0.99, P<.01), with ventilation strongly negatively linear (r{sup 2}=0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET

  5. Gyrokinetic Statistical Absolute Equilibrium and Turbulence

    SciTech Connect

    Jian-Zhou Zhu and Gregory W. Hammett

    2011-01-10

    A paradigm based on the absolute equilibrium of Galerkin-truncated inviscid systems to aid in understanding turbulence [T.-D. Lee, "On some statistical properties of hydrodynamical and magnetohydrodynamical fields," Q. Appl. Math. 10, 69 (1952)] is taken to study gyrokinetic plasma turbulence: A finite set of Fourier modes of the collisionless gyrokinetic equations are kept and the statistical equilibria are calculated; possible implications for plasma turbulence in various situations are discussed. For the case of two spatial and one velocity dimension, in the calculation with discretization also of velocity v with N grid points (where N + 1 quantities are conserved, corresponding to an energy invariant and N entropy-related invariants), the negative temperature states, corresponding to the condensation of the generalized energy into the lowest modes, are found. This indicates a generic feature of inverse energy cascade. Comparisons are made with some classical results, such as those of Charney-Hasegawa-Mima in the cold-ion limit. There is a universal shape for statistical equilibrium of gyrokinetics in three spatial and two velocity dimensions with just one conserved quantity. Possible physical relevance to turbulence, such as ITG zonal flows, and to a critical balance hypothesis are also discussed.

  6. Absolute surface energy for zincblende semiconductors

    NASA Astrophysics Data System (ADS)

    Zhang, S. B.; Wei, Su-Huai

    2003-03-01

    Recent advance in nanosciences requires the determination of surface (or facet) energy of semiconductors, which is often difficult due to the polar nature of some of the most important surfaces such as the (111)A/(111)B surfaces. Several approaches have been developed in the past [1-3] to deal with the problem but an unambiguous division of the polar surface energies is yet to come [2]. Here we show that an accurate division is indeed possible for the zincblende semiconductors and will present the results for GaAs, ZnSe, and CuInSe2 [4], respectively. A general trend emerges, relating the absolute surface energy to the ionicity of the bulk materials. [1] N. Chetty and R. M. Martin, Phys. Rev. B 45, 6074 (1992). [2] N. Moll, et al., Phys. Rev. B 54, 8844 (1996). [3] S. Mankefors, Phys. Rev. B 59, 13151 (1999). [4] S. B. Zhang and S.-H. Wei, Phys. Rev. B 65, 081402 (2002).

  7. Climate Absolute Radiance and Refractivity Observatory (CLARREO)

    NASA Technical Reports Server (NTRS)

    Leckey, John P.

    2015-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is a mission, led and developed by NASA, that will measure a variety of climate variables with an unprecedented accuracy to quantify and attribute climate change. CLARREO consists of three separate instruments: an infrared (IR) spectrometer, a reflected solar (RS) spectrometer, and a radio occultation (RO) instrument. The mission will contain orbiting radiometers with sufficient accuracy, including on orbit verification, to calibrate other space-based instrumentation, increasing their respective accuracy by as much as an order of magnitude. The IR spectrometer is a Fourier Transform spectrometer (FTS) working in the 5 to 50 microns wavelength region with a goal of 0.1 K (k = 3) accuracy. The FTS will achieve this accuracy using phase change cells to verify thermistor accuracy and heated halos to verify blackbody emissivity, both on orbit. The RS spectrometer will measure the reflectance of the atmosphere in the 0.32 to 2.3 microns wavelength region with an accuracy of 0.3% (k = 2). The status of the instrumentation packages and potential mission options will be presented.

  8. Absolute decay width measurements in 16O

    NASA Astrophysics Data System (ADS)

    Wheldon, C.; Ashwood, N. I.; Barr, M.; Curtis, N.; Freer, M.; Kokalova, Tz; Malcolm, J. D.; Spencer, S. J.; Ziman, V. A.; Faestermann, Th; Krücken, R.; Wirth, H.-F.; Hertenberger, R.; Lutter, R.; Bergmaier, A.

    2012-09-01

    The reaction 126C(63Li, d)168O* at a 6Li bombarding energy of 42 MeV has been used to populate excited states in 16O. The deuteron ejectiles were measured using the high-resolution Munich Q3D spectrograph. A large-acceptance silicon-strip detector array was used to register the recoil and break-up products. This complete kinematic set-up has enabled absolute α-decay widths to be measured with high-resolution in the 13.9 to 15.9 MeV excitation energy regime in 16O; many for the first time. This energy region spans the 14.4 MeV four-α breakup threshold. Monte-Carlo simulations of the detector geometry and break-up processes yield detection efficiencies for the two dominant decay modes of 40% and 37% for the α+12C(g.s.) and a+12C(2+1) break-up channels respectively.

  9. Absolute calibration of forces in optical tweezers

    NASA Astrophysics Data System (ADS)

    Dutra, R. S.; Viana, N. B.; Maia Neto, P. A.; Nussenzveig, H. M.

    2014-07-01

    Optical tweezers are highly versatile laser traps for neutral microparticles, with fundamental applications in physics and in single molecule cell biology. Force measurements are performed by converting the stiffness response to displacement of trapped transparent microspheres, employed as force transducers. Usually, calibration is indirect, by comparison with fluid drag forces. This can lead to discrepancies by sizable factors. Progress achieved in a program aiming at absolute calibration, conducted over the past 15 years, is briefly reviewed. Here we overcome its last major obstacle, a theoretical overestimation of the peak stiffness, within the most employed range for applications, and we perform experimental validation. The discrepancy is traced to the effect of primary aberrations of the optical system, which are now included in the theory. All required experimental parameters are readily accessible. Astigmatism, the dominant effect, is measured by analyzing reflected images of the focused laser spot, adapting frequently employed video microscopy techniques. Combined with interface spherical aberration, it reveals a previously unknown window of instability for trapping. Comparison with experimental data leads to an overall agreement within error bars, with no fitting, for a broad range of microsphere radii, from the Rayleigh regime to the ray optics one, for different polarizations and trapping heights, including all commonly employed parameter domains. Besides signaling full first-principles theoretical understanding of optical tweezers operation, the results may lead to improved instrument design and control over experiments, as well as to an extended domain of applicability, allowing reliable force measurements, in principle, from femtonewtons to nanonewtons.

  10. Absolute spectrophotometry of northern compact planetary nebulae

    NASA Astrophysics Data System (ADS)

    Wright, S. A.; Corradi, R. L. M.; Perinotto, M.

    2005-06-01

    We present medium-dispersion spectra and narrowband images of six northern compact planetary nebulae (PNe): BoBn 1, DdDm 1, IC 5117, M 1-5, M 1-71, and NGC 6833. From broad-slit spectra, total absolute fluxes and equivalent widths were measured for all observable emission lines. High signal-to-noise emission line fluxes of Hα, Hβ, [Oiii], [Nii], and HeI may serve as emission line flux standards for northern hemisphere observers. From narrow-slit spectra, we derive systemic radial velocities. For four PNe, available emission line fluxes were measured with sufficient signal-to-noise to probe the physical properties of their electron densities, temperatures, and chemical abundances. BoBn 1 and DdDm 1, both type IV PNe, have an Hβ flux over three sigma away from previous measurements. We report the first abundance measurements of M 1-71. NGC 6833 measured radial velocity and galactic coordinates suggest that it is associated with the outer arm or possibly the galactic halo, and its low abundance ([O/H]=1.3× 10-4) may be indicative of low metallicity within that region.

  11. Ex vivo lung perfusion in Brazil

    PubMed Central

    Abdalla, Luis Gustavo; Braga, Karina Andrighetti de Oliveira; Nepomuceno, Natalia Aparecida; Fernandes, Lucas Matos; Samano, Marcos Naoyuki; Pêgo-Fernandes, Paulo Manuel

    2016-01-01

    Objective: To evaluate the use of ex vivo lung perfusion (EVLP) clinically to prepare donor lungs for transplantation. Methods: A prospective study involving EVLP for the reconditioning of extended-criteria donor lungs, the criteria for which include aspects such as a PaO2/FiO2 ratio < 300 mmHg. Between February of 2013 and February of 2014, the lungs of five donors were submitted to EVLP for up to 4 h each. During EVLP, respiratory mechanics were continuously evaluated. Once every hour during the procedure, samples of the perfusate were collected and the function of the lungs was evaluated. Results: The mean PaO2 of the recovered lungs was 262.9 ± 119.7 mmHg at baseline, compared with 357.0 ± 108.5 mmHg after 3 h of EVLP. The mean oxygenation capacity of the lungs improved slightly over the first 3 h of EVLP-246.1 ± 35.1, 257.9 ± 48.9, and 288.8 ± 120.5 mmHg after 1, 2, and 3 h, respectively-without significant differences among the time points (p = 0.508). The mean static compliance was 63.0 ± 18.7 mmHg, 75.6 ± 25.4 mmHg, and 70.4 ± 28.0 mmHg after 1, 2, and 3 h, respectively, with a significant improvement from hour 1 to hour 2 (p = 0.029) but not from hour 2 to hour 3 (p = 0.059). Pulmonary vascular resistance remained stable during EVLP, with no differences among time points (p = 0.284). Conclusions: Although the lungs evaluated remained under physiological conditions, the EVLP protocol did not effectively improve lung function, thus precluding transplantation. PMID:27167429

  12. Properties of an ideal PET perfusion tracer: new PET tracer cases and data.

    PubMed

    Maddahi, Jamshid

    2012-02-01

    An ideal positron emission tomography (PET) tracer should be highly extractable by the myocardium and able to provide high-resolution images, should enable quantification of absolute myocardial blood flow (MBF), should be compatible with both pharmacologically induced and exercise-induced stress imaging, and should not require an on-site cyclotron. The PET radionuclides nitrogen-13 ammonia and oxygen-15 water require an on-site cyclotron. Rubidium-82 may be available locally due to the generator source, but greater utilization is limited because of its relatively low myocardial extraction fraction, long positron range, and generator cost. Flurpiridaz F 18, a novel PET tracer in development, has a high-extraction fraction, short positron range, and relatively long half-life (as compared to currently available tracers), and may be produced at regional cyclotrons. Results of early clinical trials suggest that both pharmacologically and exercise-induced stress PET imaging protocols can be completed more rapidly and with lower patient radiation exposure than with single-photon emission computerized tomography (SPECT) tracers. As compared to SPECT images in the same patients, flurpiridaz F 18 PET images showed better defect contrast. Flurpiridaz F 18 is a potentially promising tracer for assessment of myocardial perfusion, measurement of absolute MBF, calculation of coronary flow reserves, and assessment of cardiac function at the peak of the stress response. PMID:22259007

  13. CT Perfusion of the Liver: Principles and Applications in Oncology

    PubMed Central

    Kim, Se Hyung; Kamaya, Aya

    2014-01-01

    With the introduction of molecularly targeted chemotherapeutics, there is an increasing need for defining new response criteria for therapeutic success because use of morphologic imaging alone may not fully assess tumor response. Computed tomographic (CT) perfusion imaging of the liver provides functional information about the microcirculation of normal parenchyma and focal liver lesions and is a promising technique for assessing the efficacy of various anticancer treatments. CT perfusion also shows promising results for diagnosing primary or metastatic tumors, for predicting early response to anticancer treatments, and for monitoring tumor recurrence after therapy. Many of the limitations of early CT perfusion studies performed in the liver, such as limited coverage, motion artifacts, and high radiation dose of CT, are being addressed by recent technical advances. These include a wide area detector with or without volumetric spiral or shuttle modes, motion correction algorithms, and new CT reconstruction technologies such as iterative algorithms. Although several issues related to perfusion imaging—such as paucity of large multicenter trials, limited accessibility of perfusion software, and lack of standardization in methods—remain unsolved, CT perfusion has now reached technical maturity, allowing for its use in assessing tumor vascularity in larger-scale prospective clinical trials. In this review, basic principles, current acquisition protocols, and pharmacokinetic models used for CT perfusion imaging of the liver are described. Various oncologic applications of CT perfusion of the liver are discussed and current challenges, as well as possible solutions, for CT perfusion are presented. © RSNA, 2014 Online supplemental material is available for this article. PMID:25058132

  14. Detection of the brain response during a cognitive task using perfusion-based event-related functional MRI.

    PubMed

    Yee, S H; Liu, H L; Hou, J; Pu, Y; Fox, P T; Gao, J H

    2000-08-01

    Event-related (ER) fMRI has evoked great interest due to the ability to depict the dynamic features of human brain function during various cognitive tasks. Thus far, all cognitive ER-fMRI studies have been based on blood oxygenation level-dependent (BOLD) contrast techniques. Compared with BOLD-based fMRI techniques, perfusion-based fMRI is able to localize the region of neuronal activity more accurately. This report demonstrates, for the first time, the detection of the brain response to a cognitive task using high temporal resolution perfusion-based ER-fMRI. An English verb generation task was used in this study. Results show that perfusion-based ER-fMRI accurately depicts the activation in Broca's area. Average changes in regional relative cerebral blood flow reached a maximum value of 30.7% at approximately 6.5 s after the start of stimulation and returned to 10% of the maximum value at approximately 12.8 s. Our results show that perfusion-based ER-fMRI is a useful tool for cognitive neuroscience studies, providing comparable temporal resolution and better localization of brain function than BOLD ER-fMRI. PMID:10943717

  15. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOEpatents

    Prasad, Mano K.; Snyderman, Neal J.; Rowland, Mark S.

    2015-12-01

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  16. Absolute nuclear material assay using count distribution (LAMBDA) space

    DOEpatents

    Prasad, Manoj K.; Snyderman, Neal J.; Rowland, Mark S.

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  17. Absolute Cavity Pyrgeometer to Measure the Absolute Outdoor Longwave Irradiance with Traceability to International System of Units, SI

    SciTech Connect

    Reda, I.; Zeng, J.; Scheuch, J.; Hanssen, L.; Wilthan, B.; Myers, D.; Stoffel, T.

    2012-03-01

    This article describes a method of measuring the absolute outdoor longwave irradiance using an absolute cavity pyrgeometer (ACP), U.S. Patent application no. 13/049, 275. The ACP consists of domeless thermopile pyrgeometer, gold-plated concentrator, temperature controller, and data acquisition. The dome was removed from the pyrgeometer to remove errors associated with dome transmittance and the dome correction factor. To avoid thermal convection and wind effect errors resulting from using a domeless thermopile, the gold-plated concentrator was placed above the thermopile. The concentrator is a dual compound parabolic concentrator (CPC) with 180{sup o} view angle to measure the outdoor incoming longwave irradiance from the atmosphere. The incoming irradiance is reflected from the specular gold surface of the CPC and concentrated on the 11 mm diameter of the pyrgeometer's blackened thermopile. The CPC's interior surface design and the resulting cavitation result in a throughput value that was characterized by the National Institute of Standards and Technology. The ACP was installed horizontally outdoor on an aluminum plate connected to the temperature controller to control the pyrgeometer's case temperature. The responsivity of the pyrgeometer's thermopile detector was determined by lowering the case temperature and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The responsivity is then used to calculate the absolute atmospheric longwave irradiance with an uncertainty estimate (U{sub 95}) of {+-}3.96 W m{sup 02} with traceability to the International System of Units, SI. The measured irradiance was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the Interim World Infrared Standard Group, WISG. A total of 408 readings were collected over three different nights. The calculated irradiance measured by the ACP was 1.5 W/m{sup 2} lower than that

  18. An absolute cavity pyrgeometer to measure the absolute outdoor longwave irradiance with traceability to international system of units, SI

    NASA Astrophysics Data System (ADS)

    Reda, Ibrahim; Zeng, Jinan; Scheuch, Jonathan; Hanssen, Leonard; Wilthan, Boris; Myers, Daryl; Stoffel, Tom

    2012-03-01

    This article describes a method of measuring the absolute outdoor longwave irradiance using an absolute cavity pyrgeometer (ACP), U.S. Patent application no. 13/049, 275. The ACP consists of domeless thermopile pyrgeometer, gold-plated concentrator, temperature controller, and data acquisition. The dome was removed from the pyrgeometer to remove errors associated with dome transmittance and the dome correction factor. To avoid thermal convection and wind effect errors resulting from using a domeless thermopile, the gold-plated concentrator was placed above the thermopile. The concentrator is a dual compound parabolic concentrator (CPC) with 180° view angle to measure the outdoor incoming longwave irradiance from the atmosphere. The incoming irradiance is reflected from the specular gold surface of the CPC and concentrated on the 11 mm diameter of the pyrgeometer's blackened thermopile. The CPC's interior surface design and the resulting cavitation result in a throughput value that was characterized by the National Institute of Standards and Technology. The ACP was installed horizontally outdoor on an aluminum plate connected to the temperature controller to control the pyrgeometer's case temperature. The responsivity of the pyrgeometer's thermopile detector was determined by lowering the case temperature and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The responsivity is then used to calculate the absolute atmospheric longwave irradiance with an uncertainty estimate (U95) of ±3.96 W m-2 with traceability to the International System of Units, SI. The measured irradiance was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the Interim World Infrared Standard Group, WISG. A total of 408 readings were collected over three different nights. The calculated irradiance measured by the ACP was 1.5 W/m2 lower than that measured by the two

  19. Luminous-flux measurements by an absolute integrating sphere

    NASA Astrophysics Data System (ADS)

    Rastello, Maria Luisa; Miraldi, Elio; Pisoni, Paolo

    1996-08-01

    We present an original implementation of the absolute-sphere method recently proposed by Ohno. The luminous-flux unit, the lumen, is realized by means of an integrating sphere with an opening calibrated by a luminous-intensity standard placed outside. The adapted experimental setup permits one to measure luminous-flux values between 5 and 2500 lm with a significant improvement with respect to the simulated performances reported in the literature. Traditionally, the luminous-flux unit, the lumen, is realized by goniophotometric techniques in which the luminous-intensity distribution is measured and integrated over the whole solid angle. Thus sphere results are compared with those obtained with the Istituto Elettrotecnico Nazionale goniophotometer. In particular, a set of standards, characterized by luminous-flux values of approximately 2000 lm, has been calibrated with both techniques. We highlight some of the problems encountered. Experimental results show that the agreement between the two methods is within the estimated uncertainty and suggest promising areas for future research.

  20. An in vivo autotransplant model of renal preservation: cold storage versus machine perfusion in the prevention of ischemia/reperfusion injury.

    PubMed

    La Manna, Gaetano; Conte, Diletta; Cappuccilli, Maria Laura; Nardo, Bruno; D'Addio, Francesca; Puviani, Lorenza; Comai, Giorgia; Bianchi, Francesca; Bertelli, Riccardo; Lanci, Nicole; Donati, Gabriele; Scolari, Maria Piera; Faenza, Alessandro; Stefoni, Sergio

    2009-07-01

    There is increasing proof that organ preservation by machine perfusion is able to limit ischemia/reperfusion injury in kidney transplantation. This study was designed to compare the efficiency in hypothermic organ preservation by machine perfusion or cold storage in an animal model of kidney autotransplantation. Twelve pigs underwent left nephrectomy after warm ischemic time; the organs were preserved in machine perfusion (n = 6) or cold storage (n = 6) and then autotransplanted with immediate contralateral nephrectomy. The following parameters were compared between the two groups of animals: hematological and urine indexes of renal function, blood/gas analysis values, histological features, tissue adenosine-5'-triphosphate (ATP) content, perforin gene expression in kidney biopsies, and organ weight changes were compared before and after preservation. The amount of cellular ATP was significantly higher in organs preserved by machine perfusion; moreover, the study of apoptosis induction revealed an enhanced perforin expression in the kidneys, which underwent simple hypothermic preservation compared to the machine-preserved ones. Organ weight was significantly decreased after cold storage, but it remained quite stable for machine-perfused kidneys. The present model seems to suggest that organ preservation by hypothermic machine perfusion is able to better control cellular impairment in comparison with cold storage. PMID:19566736

  1. Contactless mapping of rhythmical phenomena in tissue perfusion using PPGI

    NASA Astrophysics Data System (ADS)

    Huelsbusch, Markus; Blazek, Vladimir

    2002-04-01

    This paper presents the experimental setup and preliminary results of a near infrared CCD camera based Photoplethysmography Imaging (PPGI) system, which has been shown to be suitable for contactless and spatially resolved assessment of rhythmical blood volume changes in the skin. To visualize the complex rhythmical patterns in the dermal perfusion the Wavelet Transform is utilized. It is able to jointly assess time and frequency behavior of signals and thus allows to analyze instationary oscillations and variabilities in the different human rhythmics. The presented system is expected to provide new insights into the functional sequences of physiological tissue perfusion as well as of the perfusion status in ulcer formation and wound healing.

  2. Perfusion CT imaging of treatment response in oncology.

    PubMed

    Prezzi, Davide; Khan, Aisha; Goh, Vicky

    2015-12-01

    Perfusion CT was first described in the 1970s but has become accepted as a clinical technique in recent years. In oncological practice Perfusion CT allows the downstream effects of therapies on the tumour vasculature to be monitored. From the dynamic changes in tumour and vascular enhancement following intravenous iodinated contrast agent administration, qualitative and quantitative parameters may be derived that reflect tumour perfusion, blood volume, and microcirculatory changes with treatment. This review outlines the mechanisms of action of available therapies and state-of-the-art imaging practice. PMID:25864440

  3. Deep Vein Thrombosis Presenting on Pulmonary Ventilation and Perfusion Scintigraphy.

    PubMed

    Itani, Malak; Fair, Joanna; Hillman, Zachary; Behnia, Fatemeh; Elojeimy, Saeed

    2016-10-01

    A 52-year-old woman presenting with dyspnea was referred for a ventilation and perfusion scan (VQ). VQ images (with Tc-DTPA [diethylene triamine pentaacetic acid aerosol] and Tc-MAA [macroaggregated albumin]) initially appeared normal; however, count rates on perfusion images were similar to ventilation images, implying little Tc-MAA had reached the lungs. Spot images of the injected extremity demonstrated focal Tc-MAA accumulation worrisome for a venous thrombus, subsequently confirmed by Doppler ultrasound. Careful attention to relative radiotracer count rates on VQ scans is crucial to ensure diagnostic utility. In addition, abnormal low perfusion radiotracer counts may unveil other pathology with important clinical implications. PMID:27556796

  4. Strong thermal leptogenesis and the absolute neutrino mass scale

    SciTech Connect

    Bari, Pasquale Di; King, Sophie E.; Fiorentin, Michele Re E-mail: sk1806@soton.ac.uk

    2014-03-01

    We show that successful strong thermal leptogenesis, where the final asymmetry is independent of the initial conditions and in particular a large pre-existing asymmetry is efficiently washed-out, favours values of the lightest neutrino mass m{sub 1}∼>10 meV for normal ordering (NO) and m{sub 1}∼>3 meV for inverted ordering (IO) for models with orthogonal matrix entries respecting |Ω{sub ij}{sup 2}|∼<2. We show analytically why lower values of m{sub 1} require a higher level of fine tuning in the seesaw formula and/or in the flavoured decay parameters (in the electronic for NO, in the muonic for IO). We also show how this constraint exists thanks to the measured values of the neutrino mixing angles and could be tightened by a future determination of the Dirac phase. Our analysis also allows us to place a more stringent constraint for a specific model or class of models, such as SO(10)-inspired models, and shows that some models cannot realise strong thermal leptogenesis for any value of m{sub 1}. A scatter plot analysis fully supports the analytical results. We also briefly discuss the interplay with absolute neutrino mass scale experiments concluding that they will be able in the coming years to either corner strong thermal leptogenesis or find positive signals pointing to a non-vanishing m{sub 1}. Since the constraint is much stronger for NO than for IO, it is very important that new data from planned neutrino oscillation experiments will be able to solve the ambiguity.

  5. The absolute disparity anomaly and the mechanism of relative disparities.

    PubMed

    Chopin, Adrien; Levi, Dennis; Knill, David; Bavelier, Daphne

    2016-06-01

    There has been a long-standing debate about the mechanisms underlying the perception of stereoscopic depth and the computation of the relative disparities that it relies on. Relative disparities between visual objects could be computed in two ways: (a) using the difference in the object's absolute disparities (Hypothesis 1) or (b) using relative disparities based on the differences in the monocular separations between objects (Hypothesis 2). To differentiate between these hypotheses, we measured stereoscopic discrimination thresholds for lines with different absolute and relative disparities. Participants were asked to judge the depth of two lines presented at the same distance from the fixation plane (absolute disparity) or the depth between two lines presented at different distances (relative disparity). We used a single stimulus method involving a unique memory component for both conditions, and no extraneous references were available. We also measured vergence noise using Nonius lines. Stereo thresholds were substantially worse for absolute disparities than for relative disparities, and the difference could not be explained by vergence noise. We attribute this difference to an absence of conscious readout of absolute disparities, termed the absolute disparity anomaly. We further show that the pattern of correlations between vergence noise and absolute and relative disparity acuities can be explained jointly by the existence of the absolute disparity anomaly and by the assumption that relative disparity information is computed from absolute disparities (Hypothesis 1). PMID:27248566

  6. The absolute disparity anomaly and the mechanism of relative disparities

    PubMed Central

    Chopin, Adrien; Levi, Dennis; Knill, David; Bavelier, Daphne

    2016-01-01

    There has been a long-standing debate about the mechanisms underlying the perception of stereoscopic depth and the computation of the relative disparities that it relies on. Relative disparities between visual objects could be computed in two ways: (a) using the difference in the object's absolute disparities (Hypothesis 1) or (b) using relative disparities based on the differences in the monocular separations between objects (Hypothesis 2). To differentiate between these hypotheses, we measured stereoscopic discrimination thresholds for lines with different absolute and relative disparities. Participants were asked to judge the depth of two lines presented at the same distance from the fixation plane (absolute disparity) or the depth between two lines presented at different distances (relative disparity). We used a single stimulus method involving a unique memory component for both conditions, and no extraneous references were available. We also measured vergence noise using Nonius lines. Stereo thresholds were substantially worse for absolute disparities than for relative disparities, and the difference could not be explained by vergence noise. We attribute this difference to an absence of conscious readout of absolute disparities, termed the absolute disparity anomaly. We further show that the pattern of correlations between vergence noise and absolute and relative disparity acuities can be explained jointly by the existence of the absolute disparity anomaly and by the assumption that relative disparity information is computed from absolute disparities (Hypothesis 1). PMID:27248566

  7. Effects of perfusion on the mechanical behavior of the brain-exposed to hypergravity.

    PubMed

    Guillaume, A; Osmont, D; Gaffie, D; Sarron, J C; Quandieu, P

    1997-04-01

    In certain flight configurations, fighter pilots are exposed to high Gz acceleration which may induce inflight loss of consciousness (G-LOC). In order to study the mechanical effects induced by these accelerations on the cerebral structures, an experimental model has been developed in vitro. Fresh bovine brains were excised and placed in a transparent mold modeling the inside of the skull. Half of these brains were perfused during the experiment. This assembly was placed into the gondola of a centrifuge, in front of a camera lens. Displacements and deformations of the brains were filmed and recorded at different onset rates. Measurements were made after off-line digitalization of images. Experimental data were incorporated into a finite element calculation code whose mesh represented the brain. The applied behavior law was elastic, the structure being considered as homogeneous and isotropic. The first results concerned the elastic properties of the brains under hypergravity. The mean value of the Young's modulus of the nonperfused brain was 46.8 kPa, which corresponded to the values published in reference literature. For the perfused brains, the mean value of the Young's modulus was higher. The mean value of the equivalent Poisson's ratio was 0.35. In fact, contrary to impacts, the mechanical stimulation is long enough to allow fluid displacements. The mean value of the equivalent Poisson's ratio calculated in the present study should probably be increased since this study was performed post mortem. PMID:9075007

  8. The isolated perfused equine distal limb as an ex vivo model for pharmacokinetic studies.

    PubMed

    Friebe, M; Stahl, J; Kietzmann, M

    2013-06-01

    Even though intra-articular injections play an important role in the treatment of joint-related lameness in horses, little is known about pharmacokinetic properties of substances used. Therefore, an ex vivo model for pharmacokinetic studies was developed using distal forelimbs of slaughtered horses. The extremity was perfused with gassed Tyrode solution for up to 8 h. Tissue viability was confirmed by measurements of glucose consumption, lactate production, and lactate dehydrogenase activity in the perfusate. Standard criteria for tissue viability had been determined in preliminary experiments (n = 11), which also included histological examinations of the joint capsule. As the model's first implementation, the articular efflux rate of betamethasone (BM), administered as BM disodium phosphate intra-articularly to the fetlock joint (4 mg BM/joint), was investigated. The concentration of BM in the venous perfusate of the radial vein was measured by means of high-performance liquid chromatography. The average BM efflux rate per minute was calculated to be 5.1 μg/min with values ranging from 9 μg/min to 2.9 μg/min. 7.5 h after i.a. application, 2.3 mg BM had left the joint via the radial vein. Using this inexpensive setup, the presented model allows studying a variety of pharmacological topics without the ethical limitations of animal studies. PMID:22913456

  9. Calculation of the Respiratory Modulation of the Photoplethysmogram (DPOP) Incorporating a Correction for Low Perfusion.

    PubMed

    Addison, Paul S; Wang, Rui; McGonigle, Scott J; Uribe, Alberto A; Bergese, Sergio D

    2014-01-01

    DPOP quantifies respiratory modulations in the photoplethysmogram. It has been proposed as a noninvasive surrogate for pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. The correlation between DPOP and PPV may degrade due to low perfusion effects. We implemented an automated DPOP algorithm with an optional correction for low perfusion. These two algorithm variants (DPOPa and DPOPb) were tested on data from 20 mechanically ventilated OR patients split into a benign "stable region" subset and a whole record "global set." Strong correlation was found between DPOP and PPV for both algorithms when applied to the stable data set: R = 0.83/0.85 for DPOPa/DPOPb. However, a marked improvement was found when applying the low perfusion correction to the global data set: R = 0.47/0.73 for DPOPa/DPOPb. Sensitivities, Specificities, and AUCs were 0.86, 0.70, and 0.88 for DPOPa/stable region; 0.89, 0.82, and 0.92 for DPOPb/stable region; 0.81, 0.61, and 0.73 for DPOPa/global region; 0.83, 0.76, and 0.86 for DPOPb/global region. An improvement was found in all results across both data sets when using the DPOPb algorithm. Further, DPOPb showed marked improvements, both in terms of its values, and correlation with PPV, for signals exhibiting low percent modulations. PMID:25177348

  10. T2∗ Measurement During First-Pass Contrast-Enhanced Cardiac Perfusion Imaging

    PubMed Central

    Kellman, Peter; Aletras, Anthony H.; Hsu, Li-yueh; McVeigh, Elliot R.; Arai, Andrew E.

    2007-01-01

    First-pass contrast-enhanced (CE) myocardial perfusion imaging will experience T2∗ effects at peak concentrations of contrast agent. A reduction in the signal intensity of left ventricular (LV) blood due to T2∗ losses may effect estimates of the arterial input function (AIF) used for quantitative perfusion measurement. Imaging artifacts may also result from T2∗ losses as well as off-resonance due to the bolus susceptibility. We hypothesized that T2∗ losses would not be significant for measurement of the AIF in full-dose studies using a short echo time (TE = 0.6 ms). The purpose of this study was to directly measure T2∗ in the LV cavity during first-pass perfusion. For single-dose Gd-DTPA (0.1 mmol/kg at 5 ml/s), the LV blood pool T2∗ had a mean value of 9 ms (N = 10) at peak enhancement. Distortion of the AIF due to T2∗ signal intensity loss will be less than 10% using TE = 0.6 ms. PMID:17029226

  11. Uptake and degradation of cytoplasmic RNA by lysosomes in the perfused rat liver

    SciTech Connect

    Heydrick, S.J.; Lardeux, B.; Mortimore, G.E.

    1987-05-01

    The release of (/sup 14/C)cytidine has been shown previously to be a valid marker for RNA degradation in rat hepatocytes. The breakdown of RNA measured with this marker in perfused livers prelabeled in vivo with (6-/sup 14/C)orotic acid was found to be regulated acutely by perfusate amino acids over a wide range, from 0.29 to 3.48%/h. This regulation paralleled that of lysosomal proteolysis. Chloroquine inhibited RNA degradation 60-70%. In subsequent cell fractionation studies labelled cytidine was released; the distribution of this release paralleled that of a lysosomal marker enzyme. The release plateaued after two hours, defining a distinct lysosomal pool of RNA. The lysosomal location of the RNA pool was confirmed in experiments where a 22% increase in the apparent pool size was obtained by lowering the homogenate pH from 7.0 to 5.5. The pool size correlated linearly with the rate of RNA degradation measured during perfusion, giving a turnover constant in reasonable agreement with values reported for autophagy. These results indicate that cytoplasmic RNA degradation occurs primarily in the lysosome and is regulated under these conditions by the amino acid control of lysosomal sequestration of cytoplasm.

  12. Changes in myocardial perfusion reserve after PTCA: noninvasive assessment with positron tomography

    SciTech Connect

    Goldstein, R.A.; Kirkeeide, R.L.; Smalling, R.W.; Nishikawa, A.; Merhige, M.E.; Demer, L.L.; Mullani, N.A.; Gould, K.L.

    1987-08-01

    The effect of percutaneous transluminal coronary angioplasty (PTCA) on myocardial perfusion reserve has not been previously determined. Accordingly, 11 patients underwent positron imaging with (/sup 13/N)ammonia or /sup 82/Rb at rest and following dipyridamole + handgrip stress before and after PTCA. The ratio of stress to rest activity (S:R) was determined for each region of interest. Relative myocardial perfusion reserve by positron tomography (RMPR) was calculated by dividing S:R of the stenotic area by a corresponding value from a normal reference area of the same patient. Automated quantitative coronary arteriography was used to objectively measure the percent diameter (%D) and the percent area narrowing (%A) of the stenoses. In nine patients with successful PTCA, %D and %A improved (68 +/- 10 to 49 +/- 15% and 92 +/- 3 to 72 +/- 5%) and RMPR increased from 0.79 +/- 0.07 to 0.96 +/- 0.05. In the two patients in whom PTCA was unsuccessful, RMPR was unchanged. Changes in RMPR correlated inversely with changes in %D (r = -0.68) and %A (r = -0.92) and directly with improved coronary flow reserve derived from all stenosis measurements (r = 0.73, p less than 0.001 for each). This study suggests that dipyridamole + handgrip stress imaging with PET can be used to assess changes in myocardial perfusion reserve before and after PTCA with the potential for determining restenosis noninvasively.

  13. Lung transplantation from donors after circulatory death using portable ex vivo lung perfusion

    PubMed Central

    Bozso, Sabin; Vasanthan, Vishnu; Luc, Jessica GY; Kinaschuk, Katie; Freed, Darren; Nagendran, Jayan

    2015-01-01

    BACKGROUND: Donation after circulatory death is a novel method of increasing the number of donor lungs available for transplantation. Using organs from donors after circulatory death has the potential to increase the number of transplants performed. METHODS: Three bilateral lung transplants from donors after circulatory death were performed over a six-month period. Following organ retrieval, all sets of lungs were placed on a portable ex vivo lung perfusion device for evaluation and preservation. RESULTS: Lung function remained stable during portable ex vivo perfusion, with improvement in partial pressure of oxygen/fraction of inspired oxygen ratios. Mechanical ventilation was discontinued within 48 h for each recipient and no patient stayed in the intensive care unit longer than eight days. There was no postgraft dysfunction at 72 h in two of the three recipients. Ninety-day mortality for all recipients was 0% and all maintain excellent forced expiratory volume in 1 s and forced vital capacity values post-transplantation. CONCLUSION: The authors report excellent results with their initial experience using donors after circulatory death after portable ex vivo lung perfusion. It is hoped this will allow for the most efficient use of available donor lungs, leading to more transplants and fewer deaths for potential recipients on wait lists. PMID:25379654

  14. Cryotherapy-Induced Persistent Vasoconstriction After Cutaneous Cooling: Hysteresis Between Skin Temperature and Blood Perfusion.

    PubMed

    Khoshnevis, Sepideh; Craik, Natalie K; Matthew Brothers, R; Diller, Kenneth R

    2016-03-01

    The goal of this study was to investigate the persistence of cold-induced vasoconstriction following cessation of active skin-surface cooling. This study demonstrates a hysteresis effect that develops between skin temperature and blood perfusion during the cooling and subsequent rewarming period. An Arctic Ice cryotherapy unit (CTU) was applied to the knee region of six healthy subjects for 60 min of active cooling followed by 120 min of passive rewarming. Multiple laser Doppler flowmetry perfusion probes were used to measure skin blood flow (expressed as cutaneous vascular conductance (CVC)). Skin surface cooling produced a significant reduction in CVC (P < 0.001) that persisted throughout the duration of the rewarming period. In addition, there was a hysteresis effect between CVC and skin temperature during the cooling and subsequent rewarming cycle (P < 0.01). Mixed model regression (MMR) showed a significant difference in the slopes of the CVC-skin temperature curves during cooling and rewarming (P < 0.001). Piecewise regression was used to investigate the temperature thresholds for acceleration of CVC during the cooling and rewarming periods. The two thresholds were shown to be significantly different (P = 0.003). The results show that localized cooling causes significant vasoconstriction that continues beyond the active cooling period despite skin temperatures returning toward baseline values. The significant and persistent reduction in skin perfusion may contribute to nonfreezing cold injury (NFCI) associated with cryotherapy. PMID:26632263

  15. Calculation of the Respiratory Modulation of the Photoplethysmogram (DPOP) Incorporating a Correction for Low Perfusion

    PubMed Central

    Addison, Paul S.; Wang, Rui; McGonigle, Scott J.; Bergese, Sergio D.

    2014-01-01

    DPOP quantifies respiratory modulations in the photoplethysmogram. It has been proposed as a noninvasive surrogate for pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. The correlation between DPOP and PPV may degrade due to low perfusion effects. We implemented an automated DPOP algorithm with an optional correction for low perfusion. These two algorithm variants (DPOPa and DPOPb) were tested on data from 20 mechanically ventilated OR patients split into a benign “stable region” subset and a whole record “global set.” Strong correlation was found between DPOP and PPV for both algorithms when applied to the stable data set: R = 0.83/0.85 for DPOPa/DPOPb. However, a marked improvement was found when applying the low perfusion correction to the global data set: R = 0.47/0.73 for DPOPa/DPOPb. Sensitivities, Specificities, and AUCs were 0.86, 0.70, and 0.88 for DPOPa/stable region; 0.89, 0.82, and 0.92 for DPOPb/stable region; 0.81, 0.61, and 0.73 for DPOPa/global region; 0.83, 0.76, and 0.86 for DPOPb/global region. An improvement was found in all results across both data sets when using the DPOPb algorithm. Further, DPOPb showed marked improvements, both in terms of its values, and correlation with PPV, for signals exhibiting low percent modulations. PMID:25177348

  16. Combined absolute and relative gravity measurement for microgravity monitoring in Aso volcanic field

    NASA Astrophysics Data System (ADS)

    Sofyan, Yayan; Nishijima, Jun; Yoshikawa, Shin; Fujimitsu, Yasuhiro; Kagiyama, Tsuneomi; Fukuda, Yoichi

    2014-05-01

    Absolute measurement with a portable A10-017 absolute gravimeter at some benchmarks in the Aso volcanic field are valuable for reducing uncertainties of regional gravity variations and will be useful for delineating the long term trends of gravity changes. A10 absolute gravimeter is a new generation of portable absolute instrument and has accuracy 10 microGal. To further the development of a high precision gravity data, we also conducted measurement using two relative gravimeter (Scintrex CG-5 [549] and LaCoste type G-1016) to be combined with an A10 absolute gravimeter. The using absolute gravimeter along with relative gravimeter can reduce drift correction factor and improve the result of gravity change data in microgravity monitoring. Microgravity monitoring is a valued tool for mapping the redistribution of subsurface mass and for assessing changes in the fluid as a dynamic process in volcanic field. Gravity changes enable the characterization of subsurface processes: i.e., the mass of the intrusion or hydrothermal flow. A key assumption behind gravity monitoring is that changes in earth's gravity reflect mass-transport processes at depth [1]. The absolute gravity network was installed at seven benchmarks using on May 2010, which re-occupied in October 2010, and June 2011. The relative gravity measurements were performed at 28 benchmarks in one month before the eruption on May 2011 and then followed by series of gravity monitoring after the eruption in every three to five months. Gravity measurements covered the area more than 60 km2 in the west side of Aso caldera. Some gravity benchmarks were measured using both absolute and relative gravimeter and is used as the reference benchmarks. In longer time period, the combined gravity method will improve the result of gravity change data for monitoring in the Aso volcanic field. As a result, the gravity changes detected the hydrothermal flow in the subsurface which has a correlation to water level fluctuation in the

  17. Prognostic Value of Coronary Flow Reserve in Patients with Dialysis-Dependent ESRD.

    PubMed

    Shah, Nishant R; Charytan, David M; Murthy, Venkatesh L; Skali Lami, Hicham; Veeranna, Vikas; Cheezum, Michael K; Taqueti, Viviany R; Kato, Takashi; Foster, Courtney R; Hainer, Jon; Gaber, Mariya; Klein, Josh; Dorbala, Sharmila; Blankstein, Ron; Di Carli, Marcelo F

    2016-06-01

    Capillary rarefaction of the coronary microcirculation is a consistent phenotype in patients with dialysis-dependent ESRD (dd-ESRD) and may help explain their excess mortality. Global coronary flow reserve (CFR) assessed by positron emission tomography (PET) is a noninvasive, quantitative marker of myocardial perfusion and ischemia that integrates the hemodynamic effects of epicardial stenosis, diffuse atherosclerosis, and microvascular dysfunction. We tested whether global CFR provides risk stratification in patients with dd-ESRD. Consecutive patients with dd-ESRD clinically referred for myocardial perfusion PET imaging were retrospectively included, excluding patients with prior renal transplantation. Per-patient CFR was calculated as the ratio of stress to rest absolute myocardial blood flow. Multivariable Cox proportional hazards models, including age, overt cardiovascular disease, and myocardial scar/ischemia burden, were used to assess the independent association of global CFR with all-cause and cardiovascular mortality. The incremental value of global CFR was assessed with relative integrated discrimination index and net reclassification improvement. In 168 patients included, median global CFR was 1.4 (interquartile range, 1.2-1.8). During follow-up (median of 3 years), 36 patients died, including 21 cardiovascular deaths. Log-transformed global CFR independently associated with all-cause mortality (hazard ratio, 0.01 per 0.5-unit increase; 95% confidence interval, <0.01 to 0.14; P<0.001) and cardiovascular mortality (hazard ratio, 0.01 per 0.5-unit increase; 95% confidence interval, <0.01 to 0.15; P=0.002). For all-cause mortality, addition of global CFR resulted in risk reclassification in 27% of patients. Thus, global CFR may provide independent and incremental risk stratification for all-cause and cardiovascular mortality in patients with dd-ESRD. PMID:26459635

  18. Orion Absolute Navigation System Progress and Challenge

    NASA Technical Reports Server (NTRS)

    Holt, Greg N.; D'Souza, Christopher

    2012-01-01

    The absolute navigation design of NASA's Orion vehicle is described. It has undergone several iterations and modifications since its inception, and continues as a work-in-progress. This paper seeks to benchmark the current state of the design and some of the rationale and analysis behind it. There are specific challenges to address when preparing a timely and effective design for the Exploration Flight Test (EFT-1), while still looking ahead and providing software extensibility for future exploration missions. The primary onboard measurements in a Near-Earth or Mid-Earth environment consist of GPS pseudo-range and delta-range, but for future explorations missions the use of star-tracker and optical navigation sources need to be considered. Discussions are presented for state size and composition, processing techniques, and consider states. A presentation is given for the processing technique using the computationally stable and robust UDU formulation with an Agee-Turner Rank-One update. This allows for computational savings when dealing with many parameters which are modeled as slowly varying Gauss-Markov processes. Preliminary analysis shows up to a 50% reduction in computation versus a more traditional formulation. Several state elements are discussed and evaluated, including position, velocity, attitude, clock bias/drift, and GPS measurement biases in addition to bias, scale factor, misalignment, and non-orthogonalities of the accelerometers and gyroscopes. Another consideration is the initialization of the EKF in various scenarios. Scenarios such as single-event upset, ground command, and cold start are discussed as are strategies for whole and partial state updates as well as covariance considerations. Strategies are given for dealing with latent measurements and high-rate propagation using multi-rate architecture. The details of the rate groups and the data ow between the elements is discussed and evaluated.

  19. Evaluation of the Absolute Regional Temperature Potential

    NASA Technical Reports Server (NTRS)

    Shindell, D. T.

    2012-01-01

    The Absolute Regional Temperature Potential (ARTP) is one of the few climate metrics that provides estimates of impacts at a sub-global scale. The ARTP presented here gives the time-dependent temperature response in four latitude bands (90-28degS, 28degS-28degN, 28-60degN and 60-90degN) as a function of emissions based on the forcing in those bands caused by the emissions. It is based on a large set of simulations performed with a single atmosphere-ocean climate model to derive regional forcing/response relationships. Here I evaluate the robustness of those relationships using the forcing/response portion of the ARTP to estimate regional temperature responses to the historic aerosol forcing in three independent climate models. These ARTP results are in good accord with the actual responses in those models. Nearly all ARTP estimates fall within +/-20%of the actual responses, though there are some exceptions for 90-28degS and the Arctic, and in the latter the ARTP may vary with forcing agent. However, for the tropics and the Northern Hemisphere mid-latitudes in particular, the +/-20% range appears to be roughly consistent with the 95% confidence interval. Land areas within these two bands respond 39-45% and 9-39% more than the latitude band as a whole. The ARTP, presented here in a slightly revised form, thus appears to provide a relatively robust estimate for the responses of large-scale latitude bands and land areas within those bands to inhomogeneous radiative forcing and thus potentially to emissions as well. Hence this metric could allow rapid evaluation of the effects of emissions policies at a finer scale than global metrics without requiring use of a full climate model.

  20. Absolute optical surface measurement with deflectometry

    NASA Astrophysics Data System (ADS)

    Li, Wansong; Sandner, Marc; Gesierich, Achim; Burke, Jan

    Deflectometry utilises the deformation and displacement of a sample pattern after reflection from a test surface to infer the surface slopes. Differentiation of the measurement data leads to a curvature map, which is very useful for surface quality checks with sensitivity down to the nanometre range. Integration of the data allows reconstruction of the absolute surface shape, but the procedure is very error-prone because systematic errors may add up to large shape deviations. In addition, there are infinitely many combinations for slope and object distance that satisfy a given observation. One solution for this ambiguity is to include information on the object's distance. It must be known very accurately. Two laser pointers can be used for positioning the object, and we also show how a confocal chromatic distance sensor can be used to define a reference point on a smooth surface from which the integration can be started. The used integration algorithm works without symmetry constraints and is therefore suitable for free-form surfaces as well. Unlike null testing, deflectometry also determines radius of curvature (ROC) or focal lengths as a direct result of the 3D surface reconstruction. This is shown by the example of a 200 mm diameter telescope mirror, whose ROC measurements by coordinate measurement machine and deflectometry coincide to within 0.27 mm (or a sag error of 1.3μm). By the example of a diamond-turned off-axis parabolic mirror, we demonstrate that the figure measurement uncertainty comes close to a well-calibrated Fizeau interferometer.